WorldWideScience

Sample records for spontaneous magnetization ms

  1. Magnetic and spontaneous Barkhausen noise techniques used in investigation of a martensitic transformation

    Science.gov (United States)

    Capò Sànchez, J.; Huallpa, E.; Farina, P.; Padovese, L. R.; Goldenstein, H.

    2011-10-01

    Magnetic Barkhausen noise (MBN) was used to characterize the progress of austenite to martensite phase transformation while cooling steel specimens, using a conventional Barkhausen noise emission setup stimulated by an alternating magnetic field. The phase transformation was also followed by electrical resistivity measurements and by optical and scanning electron microscopy. MBN measurements on a AISI D2 tool steel austenitized at 1473 K and cooled to liquid nitrogen temperature presented a clear change near 225 K during cooling, corresponding to the MS (martensite start) temperature, as confirmed by resistivity measurements. Analysis of the resulting signals suggested a novel experimental technique that measures spontaneous magnetic emission during transformation, in the absence of any external field. Spontaneous magnetic noise emission measurements were registered in situ while cooling an initially austenitic sample in liquid nitrogen, showing that local microstructural changes, corresponding to an avalanche or "burst" phenomena, could be detected. This spontaneous magnetic emission (SME) can thus be considered a new experimental tool for the study of martensite transformations in ferrous alloys, at the same level as acoustic emission.

  2. Spontaneous magnetization in high-density quark matter

    DEFF Research Database (Denmark)

    Tsue, Yasuhiko; da Providência, João; Providência, Constanca

    2015-01-01

    It is shown that spontaneous magnetization occurs due to the anomalous magnetic moments of quarks in high-density quark matter under the tensor-type four-point interaction. The spin polarized condensate for each flavor of quark appears at high baryon density, which leads to the spontaneous magnet...

  3. Spontaneous magnetic alignment behaviour in free-living lizards

    Science.gov (United States)

    Diego-Rasilla, Francisco J.; Pérez-Mellado, Valentín; Pérez-Cembranos, Ana

    2017-04-01

    Several species of vertebrates exhibit spontaneous longitudinal body axis alignment relative to the Earth's magnetic field (i.e., magnetic alignment) while they are performing different behavioural tasks. Since magnetoreception is still not fully understood, studying magnetic alignment provides evidence for magnetoreception and broadens current knowledge of magnetic sense in animals. Furthermore, magnetic alignment widens the roles of magnetic sensitivity in animals and may contribute to shed new light on magnetoreception. In this context, spontaneous alignment in two species of lacertid lizards ( Podarcis muralis and Podarcis lilfordi) during basking periods was monitored. Alignments in 255 P. muralis and 456 P. lilfordi were measured over a 5-year period. The possible influence of the sun's position (i.e., altitude and azimuth) and geomagnetic field values corresponding to the moment in which a particular lizard was observed on lizards' body axis orientation was evaluated. Both species exhibited a highly significant bimodal orientation along the north-northeast and south-southwest magnetic axis. The evidence from this study suggests that free-living lacertid lizards exhibit magnetic alignment behaviour, since their body alignments cannot be explained by an effect of the sun's position. On the contrary, lizard orientations were significantly correlated with geomagnetic field values at the time of each observation. We suggest that this behaviour might provide lizards with a constant directional reference while they are sun basking. This directional reference might improve their mental map of space to accomplish efficient escape behaviour. This study is the first to provide spontaneous magnetic alignment behaviour in free-living reptiles.

  4. Electrically Controllable Spontaneous Magnetism in Nanoscale Mixed Phase Multiferroics

    Energy Technology Data Exchange (ETDEWEB)

    He, Q.; Chu, Y. H.; Heron, J. T.; Yang, S. Y.; Wang, C. H.; Kuo, C. Y.; Lin, H. J.; Yu, P.; Liang, C. W.; Zeches, R. J.; Chen, C. T.; Arenholz, E.; Scholl, A.; Ramesh, R.

    2010-08-02

    The emergence of enhanced spontaneous magnetic moments in self-assembled, epitaxial nanostructures of tetragonal (T-phase) and rhombohedral phases (R-phase) of the multiferroic BiFeO{sub 3} system is demonstrated. X-ray magnetic circular dichroism based photoemission electron microscopy (PEEM) was applied to investigate the local nature of this magnetism. We find that the spontaneous magnetization of the R-phase is significantly enhanced above the canted antiferromagnetic moment in the bulk phase, as a consequence of a piezomagnetic coupling to the adjacent T-phase and the epitaxial constraint. Reversible electric field control and manipulation of this magnetic moment at room temperature is shown using a combination of piezoresponse force microscopy and PEEM studies.

  5. Particle-in-cell simulations on spontaneous thermal magnetic field fluctuations

    Energy Technology Data Exchange (ETDEWEB)

    Simões, F. J. R. Jr.; Pavan, J. [Instituto de Física e Matemática, UFPel, Pelotas, RS (Brazil); Gaelzer, R.; Ziebell, L. F. [Instituto de Física, UFRGS, Porto Alegre, RS (Brazil); Yoon, P. H. [Institute for Physical Science and Technology, University of Maryland, College Park, Maryland 20742 (United States)

    2013-10-15

    In this paper an electromagnetic particle code is used to investigate the spontaneous thermal emission. Specifically we perform particle-in-cell simulations employing a non-relativistic isotropic Maxwellian particle distribution to show that thermal fluctuations are related to the origin of spontaneous magnetic field fluctuation. These thermal fluctuations can become seed for further amplification mechanisms and thus be considered at the origin of the cosmological magnetic field, at microgauss levels. Our numerical results are in accordance with theoretical results presented in the literature.

  6. Magnetohydrodynamic study of three-dimensional instability of the spontaneous fast magnetic reconnection

    International Nuclear Information System (INIS)

    Shimizu, T.; Kondoh, K.; Ugai, M.; Shibata, K.

    2009-01-01

    Three-dimensional instability of the spontaneous fast magnetic reconnection is studied with magnetohydrodynamic (MHD) simulation, where the two-dimensional model of the spontaneous fast magnetic reconnection is destabilized in three dimension. Generally, in two-dimensional magnetic reconnection models, every plasma condition is assumed to be uniform in the sheet current direction. In such two-dimensional MHD simulations, the current sheet destabilized by the initial resistive disturbance can be developed to fast magnetic reconnection by a current driven anomalous resistivity. In this paper, the initial resistive disturbance includes a small amount of fluctuations in the sheet current direction, i.e., along the magnetic neutral line. The other conditions are the same as that of previous two-dimensional MHD studies for fast magnetic reconnection. Accordingly, we may expect that approximately two-dimensional fast magnetic reconnection occurs in the MHD simulation. In fact, the fast magnetic reconnection activated on the first stage of the simulation is two dimensional. However, on the subsequent stages, it spontaneously becomes three dimensional and is strongly localized in the sheet current direction. The resulting three-dimensional fast magnetic reconnection intermittently ejects three-dimensional magnetic loops. Such intermittent ejections of the three-dimensional loops are similar to the intermittent downflows observed in the solar flares. The ejection of the three-dimensional loops seems to be random but, numerically and theoretically, it is shown that the aspect ratio of the ejected loops is limited under a criterion.

  7. Spontaneous Magnetization in the Dipolar Ising Ferromagnet LiTbF4

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage; Holmes, L. M.; Krebs Larsen, F.

    1975-01-01

    The spontaneous magnetization μ in Bohr magnetons below TC=2.874 K in LiTbF4 has been measured by magnetic Bragg scattering of neutrons. The data were normalized by comparing the magnetic Bragg scattering to the nuclear Bragg scattering at T>TC. The nuclear structure factors as well...

  8. Spontaneous expression of magnetic compass orientation in an epigeic rodent: the bank vole, Clethrionomys glareolus

    Science.gov (United States)

    Oliveriusová, Ludmila; Němec, Pavel; Pavelková, Zuzana; Sedláček, František

    2014-07-01

    Magnetoreception has been convincingly demonstrated in only a few mammalian species. Among rodents, magnetic compass orientation has been documented in four species of subterranean mole rats and two epigeic (i.e. active above ground) species—the Siberian hamster and the C57BL/6J mouse. The mole rats use the magnetic field azimuth to determine compass heading; their directional preference is spontaneous and unimodal, and their magnetic compass is magnetite-mediated. By contrast, the primary component of orientation response is learned in the hamster and the mouse, but both species also exhibit a weak spontaneous bimodal preference in the natural magnetic field. To determine whether the magnetic compass of wild epigeic rodents features the same functional properties as that of laboratory rodents, we investigated magnetic compass orientation in the bank vole Clethrionomys glareolus (Cricetidae, Rodentia). The voles exhibited a robust spontaneous bimodal directional preference, i.e. built nests and slept preferentially along the north-south axis, and deflected their directional preference according to a shift in the direction of magnetic north, clearly indicating that they were deriving directional information from the magnetic field. Thus, bimodal, axially symmetrical directional choice seems to be a common feature shared by epigeic rodents. However, spontaneous directional preference in the bank vole appeared to be more pronounced than that reported in the hamster and the mouse. These findings suggest that bank voles are well suited for future studies investigating the adaptive significance and mechanisms of magnetic orientation in epigeic rodents.

  9. Spontaneous magnetization of quantum XY-chain from finite chain form-factor

    International Nuclear Information System (INIS)

    Iorgov, N.Z.

    2010-01-01

    Using the explicit factorized formulas for matrix elements (form-factors) of the spin operators between vectors of the Hamiltonian of a finite quantum XY-chain in a transverse field, the spontaneous magnetization for σ x and σ y is re-derived in a simple way.

  10. Spontaneous magnetization of thin films of ordered and disordered alloys of transition metals

    International Nuclear Information System (INIS)

    Nguyen Nhat Khanh.

    1989-12-01

    A method of calculation of spontaneous magnetization of thin films of transition metal alloys is described. The method is based on the Hubbard model for d electrons. Use of the Bragg-Williams approximation and two-dimensional canonical transformations has allowed to calculate the magnetization. Results for a Ni 3 Fe thin film are presented. (author). 11 refs, 1 fig

  11. Intrinsic magnetism and spontaneous band gap opening in bilayer silicene and germanene.

    Science.gov (United States)

    Wang, Xinquan; Wu, Zhigang

    2017-01-18

    It has been long sought to create magnetism out of simple non-magnetic materials, such as silicon and germanium. Here we show that intrinsic magnetism exists in bilayer silicene and germanene with no need to cut, etch, or dope. Unlike bilayer graphene, strong covalent interlayer bonding formed in bilayer silicene and germanene breaks the original π-bonding network of each layer, leaving the unbonded electrons unpaired and localized to carry magnetic moments. These magnetic moments then couple ferromagnetically within each layer while antiferromagnetically across two layers, giving rise to an infinite magnetic sheet with structural integrity and magnetic homogeneity. Furthermore, this unique magnetic ordering results in fundamental band gaps of 0.55 eV and 0.32 eV for bilayer silicene and germanene, respectively. The integration of intrinsic magnetism and spontaneous band gap opening makes bilayer silicene and germanene attractive for future nanoelectronics as well as spin-based computation and data storage.

  12. Observation of magnetic flux generated spontaneously during a rapid quench of superconducting films

    International Nuclear Information System (INIS)

    Maniv, A.; Polturak, E.; Koren, G.

    2003-01-01

    We report observations of spontaneous formation of magnetic flux lines during a rapid quench of YBa 2 Cu 3 O 7-δ films through T c . This effect is predicted according to the Kibble-Zurek mechanism of creation of topological defects of the order parameter during a symmetry-breaking phase transition. Our previous experiment, at a quench rate of 20 K/s, gave null results. In the present experiment, the quench rate was increased to >10 8 K/s. The amount of spontaneous flux increases weakly with the cooling rate

  13. Magnetism, Superconductivity, and Spontaneous Orbital Order in Iron-Based Superconductors: Which Comes First and Why?

    Directory of Open Access Journals (Sweden)

    Andrey V. Chubukov

    2016-12-01

    Full Text Available Magnetism and nematic order are the two nonsuperconducting orders observed in iron-based superconductors. To elucidate the interplay between them and ultimately unveil the pairing mechanism, several models have been investigated. In models with quenched orbital degrees of freedom, magnetic fluctuations promote stripe magnetism, which induces orbital order. In models with quenched spin degrees of freedom, charge fluctuations promote spontaneous orbital order, which induces stripe magnetism. Here, we develop an unbiased approach, in which we treat magnetic and orbital fluctuations on equal footing. Key to our approach is the inclusion of the orbital character of the low-energy electronic states into renormalization group (RG analysis. We analyze the RG flow of the couplings and argue that the same magnetic fluctuations, which are known to promote s^{+-} superconductivity, also promote an attraction in the orbital channel, even if the bare orbital interaction is repulsive. We next analyze the RG flow of the susceptibilities and show that, if all Fermi pockets are small, the system first develops a spontaneous orbital order, then s^{+-} superconductivity, and magnetic order does not develop down to T=0. We argue that this scenario applies to FeSe. In systems with larger pockets, such as BaFe_{2}As_{2} and LaFeAsO, we find that the leading instability is either towards a spin-density wave or superconductivity. We argue that in this situation nematic order is caused by composite spin fluctuations and is vestigial to stripe magnetism. Our results provide a unifying description of different iron-based materials.

  14. Proposed Spontaneous Generation of Magnetic Fields by Curved Layers of a Chiral Superconductor

    Science.gov (United States)

    Kvorning, T.; Hansson, T. H.; Quelle, A.; Smith, C. Morais

    2018-05-01

    We demonstrate that two-dimensional chiral superconductors on curved surfaces spontaneously develop magnetic flux. This geometric Meissner effect provides an unequivocal signature of chiral superconductivity, which could be observed in layered materials under stress. We also employ the effect to explain some puzzling questions related to the location of zero-energy Majorana modes.

  15. Spontaneous intracranial hypotension syndrome: magnetic resonance findings in two patients

    International Nuclear Information System (INIS)

    Ortega, R.; Pastor, J.; Escamilla, F.; Romero, M. I.

    1999-01-01

    The postural headache syndrome associated with a decrease in the cerebrospinal fluid (CSF) pressure is generally secondary to the CSF leakage that usually occurs after diagnostic lumbar puncture. Spontaneous intracranial hypotension can not be attributed to any known cause or previous diagnostic or therapeutic intervention. The syndrome is characterized by severe headache that is relieved by lying supine. During lumbar puncture, the CSF pressure is normally low. We present two patients in whom gadolinium-enhanced magnetic resonance imaging showed widespread thickening and enhancement of the dura mater and subdural fluid collections. (Author) 13 refs

  16. Pathological Assessment of Brain White Matter in Relapsing-Remitting MS Patients using Quantitative Magnetization Transfer Imaging

    Directory of Open Access Journals (Sweden)

    Khodarahm Pahlevan

    2011-09-01

    Full Text Available Introduction: Multiple sclerosis (MS is characterized by lesions in the white matter (WM of the central nervous system. Magnetic resonance imaging is the most specific and sensitive method for diagnosis of multiple sclerosis. However, the ability of conventional MRI to show histopathologic heterogeneity of MS lesions is insufficient. Quantitative magnetization transfer imaging (qMTI is a relatively new method to investigate pathologic processes of the brain tissue occurring in MS patients. Material and Methods: Voxel-based analyses allow regional comparisons between groups to be made for the whole brain in a single analysis. This is done by coregistering data from all individual subjects to a reference brain, generally referred to as the "standard space", and then comparing them on a voxel-by-voxel basis. This study aimed to analyze whole-brain quantitative T1 maps, not to find global changes or changes in selected regions, but specifically to investigate the spatial distribution throughout the brain of T1 increases in MS WM with respect to control WM. In this study, 11 healthy controls, 10 relapsing-remitting (RR MS patients and 13 CIS patients were studied using MT-MRI imaging. MT parameters, including magnetization transfer ratio (MTR, magnetization transfer rate between free protons and restricted macromolecular protons, Ksat and longitudinal relaxation times (with and without MT saturation pulse, T1sat and T1free values were evaluated. Results: The results showed that, at a group level, there is widespread involvement of WM throughout the brain in CIS MS and especially in RRMS, where a significant T1 increase was found in 15.58% of WM voxels (normals < RR. Discussion and Conclusion: This study demonstrates that WM in large parts of the brain is susceptible to disease processes in RR and CIS MS

  17. Engineering and Scaling the Spontaneous Magnetization Reversal of Faraday Induced Magnetic Relaxation in Nano-Sized Amorphous Ni Coated on Crystalline Au.

    Science.gov (United States)

    Li, Wen-Hsien; Lee, Chi-Hung; Kuo, Chen-Chen

    2016-05-28

    We report on the generation of large inverse remanent magnetizations in nano-sized core/shell structure of Au/Ni by turning off the applied magnetic field. The remanent magnetization is very sensitive to the field reduction rate as well as to the thermal and field processes before the switching off of the magnetic field. Spontaneous reversal in direction and increase in magnitude of the remanent magnetization in subsequent relaxations over time were found. All of the various types of temporal relaxation curves of the remanent magnetizations are successfully scaled by a stretched exponential decay profile, characterized by two pairs of relaxation times and dynamic exponents. The relaxation time is used to describe the reduction rate, while the dynamic exponent describes the dynamical slowing down of the relaxation through time evolution. The key to these effects is to have the induced eddy current running beneath the amorphous Ni shells through Faraday induction.

  18. Modulation of Jahn-Teller effect on magnetization and spontaneous electric polarization of CuFeO2

    Science.gov (United States)

    Xiao, Guiling; Xia, Zhengcai; Wei, Meng; Huang, Sha; Shi, Liran; Zhang, Xiaoxing; Wu, Huan; Yang, Feng; Song, Yujie; Ouyang, Zhongwen

    2018-03-01

    CuFe0.99Mn0.01O2 and CuFe0.99Co0.01O2 single crystal samples are grown by a floating zone technique and their magnetization and spontaneous electric polarization have been investigated. Similarly with pure CuFeO2, an obviously anisotropic magnetization and spontaneous electric polarization were observed in the both doped samples, and their phase transition critical fields and temperatures are directly doping ion dependent. Considering the different d-shell configuration and ionic size between Mn3+, Co3+ and Fe3+ ions, in which the Mn3+ ion with Jahn-Teller (J-T) effect has different distortion on the geometry frustration from both of Fe3+ and Co3+ ion. Since for Mn3+ ion, the orbital splitting results from the low-symmetry J-T distortion in a crystal-field environment leads to a distorted MnO6 octahedron, which different from undistorted FeO6 and CoO6 octahedrons. The strain between distorted and undistorted octahedrons produces different effects on the spin reorientation transition and spontaneous electric polarization. Although the pure CuFeO2 has a very strong and robust frustration, the presence of the strain due to the random distribution of distorted MnO6 octahedron and undistorted CoO6 (FeO6) octahedrons leads to its spin reorientation transitions and spontaneous electric polarization different from CuFeO2.

  19. Engineering and Scaling the Spontaneous Magnetization Reversal of Faraday Induced Magnetic Relaxation in Nano-Sized Amorphous Ni Coated on Crystalline Au

    Science.gov (United States)

    Li, Wen-Hsien; Lee, Chi-Hung; Kuo, Chen-Chen

    2016-01-01

    We report on the generation of large inverse remanent magnetizations in nano-sized core/shell structure of Au/Ni by turning off the applied magnetic field. The remanent magnetization is very sensitive to the field reduction rate as well as to the thermal and field processes before the switching off of the magnetic field. Spontaneous reversal in direction and increase in magnitude of the remanent magnetization in subsequent relaxations over time were found. All of the various types of temporal relaxation curves of the remanent magnetizations are successfully scaled by a stretched exponential decay profile, characterized by two pairs of relaxation times and dynamic exponents. The relaxation time is used to describe the reduction rate, while the dynamic exponent describes the dynamical slowing down of the relaxation through time evolution. The key to these effects is to have the induced eddy current running beneath the amorphous Ni shells through Faraday induction. PMID:28773549

  20. Spontaneous electric polarization in the B-site magnetic spinel GeCu2O4

    Science.gov (United States)

    Yanda, Premakumar; Ghara, Somnath; Sundaresan, A.

    2018-04-01

    We report the observation of a spontaneous electric polarization at the antiferromagnetic ordering temperature (TN ∼ 33 K) of Cu2+ ions in the B-site magnetic spinel GeCu2O4, synthesized at high pressure and high temperature. This compound is known to crystallize in a tetragonal structure (space group I41/amd) due to Jahn-Teller distortion of Cu2+ ions and exhibit a collinear up-up-down-down (↑↑↓↓) antiferromagnetic spin configuration below TN. We found a clear dielectric anomaly at TN, where an electric polarization appears in the absence of applied magnetic field. The electric polarization is suppressed by applied magnetic fields, which demonstrates that the compound GeCu2O4 is a type-II multiferroic.

  1. Controlled and spontaneous magnetic field generation in a gun-driven spheromak

    International Nuclear Information System (INIS)

    Woodruff, S.; Cohen, B.I.; Hooper, E.B.; Mclean, H.S.; Stallard, B.W.; Hill, D.N.; Holcomb, C.T.; Romero-Talamas, C.; Wood, R.D.; Cone, G.; Sovinec, C.R.

    2005-01-01

    In the Sustained Spheromak Physics Experiment, SSPX [E. B. Hooper, D. Pearlstein, and D. D. Ryutov, Nucl. Fusion 39, 863 (1999)], progress has been made in understanding the mechanisms that generate fields by helicity injection. SSPX injects helicity (linked magnetic flux) from 1 m diameter magnetized coaxial electrodes into a flux-conserving confinement region. Control of magnetic fluctuations (δB/B∼1% on the midplane edge) yields T e profiles peaked at >200 eV. Trends indicate a limiting beta (β e ∼4%-6%), and so we have been motivated to increase T e by operating with stronger magnetic field. Two new operating modes are observed to increase the magnetic field: (A) Operation with constant current and spontaneous gun voltage fluctuations. In this case, the gun is operated continuously at the threshold for ejection of plasma from the gun: stored magnetic energy of the spheromak increases gradually with δB/B∼2% and large voltage fluctuations (δV∼1 kV), giving a 50% increase in current amplification, I tor /I gun . (B) Operation with controlled current pulses. In this case, spheromak magnetic energy increases in a stepwise fashion by pulsing the gun, giving the highest magnetic fields observed for SSPX (∼0.7 T along the geometric axis). By increasing the time between pulses, a quasisteady sustainment is produced (with periodic good confinement), comparing well with resistive magnetohydrodynamic simulations. In each case, the processes that transport the helicity into the spheromak are inductive and exhibit a scaling of field with current that exceeds those previously obtained. We use our newly found scaling to suggest how to achieve higher temperatures with a series of pulses

  2. Controlled and Spontaneous Magnetic Field Generation in a Gun-Driven Spheromak

    International Nuclear Information System (INIS)

    Woodruff, S; Cohen, B I; Hooper, E B; McLean, H S; Stallard, B W; Hill, D N; Holcomb, C T; Romero-Talamas, C; Wood, R D; Cone, G; Sovinec, C R

    2005-04-01

    In the Sustained Spheromak Physics Experiment, SSPX, progress has been made in understanding the mechanisms that generate fields by helicity injection. SSPX injects helicity (linked magnetic flux) from 1-m diameter magnetized coaxial electrodes into a flux-conserving confinement region. Control of magnetic fluctuations ((delta)B/B∼1% on the midplane edge) yields T e profiles peaked at > 200eV. Trends indicate a limiting beta (β e ∼ 4-6%), and so we have been motivated to increase T e by operating with stronger magnetic field. Two new operating modes are observed to increase the magnetic field: (A) Operation with constant current and spontaneous gun voltage fluctuations. In this case, the gun is operated continuously at the threshold for ejection of plasma from the gun: stored magnetic energy of the spheromak increases gradually with (delta)B/B ∼2% and large voltage fluctuations ((delta)V ∼ 1kV), giving a 50% increase in current amplification, I tor /I gun . (B) Operation with controlled current pulses. In this case, spheromak magnetic energy increases in a stepwise fashion by pulsing the gun, giving the highest magnetic fields observed for SSPX (∼0.7T along the geometric axis). By increasing the time between pulses, a quasi-steady sustainment is produced (with periodic good confinement), comparing well with resistive MHD simulations. In each case, the processes that transport the helicity into the spheromak are inductive and exhibit a scaling of field with current that exceeds those previously obtained. We use our newly found scaling to suggest how to achieve higher temperatures with a series of pulses

  3. Spontaneous intracranial hypotension.

    LENUS (Irish Health Repository)

    Fullam, L

    2012-01-31

    INTRODUCTION: Spontaneous\\/primary intracranial hypotension is characterised by orthostatic headache and is associated with characteristic magnetic resonance imaging findings. CASE REPORT: We present a case report of a patient with typical symptoms and classical radiological images. DISCUSSION: Spontaneous intracranial hypotension is an under-recognised cause of headache and can be diagnosed by history of typical orthostatic headache and findings on MRI brain.

  4. Spontaneous Intracranial Hypotension without Orthostatic Headache

    Directory of Open Access Journals (Sweden)

    Tülay Kansu

    2009-03-01

    Full Text Available We report 2 cases of spontaneous intracranial hypotension that presented with unilateral abducens nerve palsy, without orthostatic headache. While sixth nerve palsies improved without any intervention, subdural hematoma was detected with magnetic resonance imaging. We conclude that headache may be absent in spontaneous intracranial hypotension and spontaneous improvement of sixth nerve palsy can occur, even after the development of a subdural hematoma

  5. The Assessment of Structural Changes in MS Plaques and Normal Appearing White Matter Using Quantitative Magnetization Transfer Imaging (MTI

    Directory of Open Access Journals (Sweden)

    Masoomeh Fooladi

    2007-12-01

    Full Text Available Introduction: Multiple sclerosis (MS is a demyelinating disease of the central nervous system (CNS, affecting mostly young people at a mean age of 30 years. Magnetic resonance imaging (MRI is one of the most specific and sensitive methods in diagnosing and detecting the evolution of multiple sclerosis disease. But it does not have the ability to differentiate between distinct histopathological heterogeneities that occur in MS lesions and brain tissue.Quantitative magnetization transfer imaging (qMTI is a relatively new MRI technique which can be used to examine the pathological processes of the brain parenchyma which occur in MS patients.This quantitative MRI technique can provide more complete information about the extent and nature of the brain tissue destruction in multiple sclerosis, which cannot be detected by conventional MRI. Material and Methods: In this study, twelve patients with relapsing-remitting MS and twelve healthy control subjects underwent conventional MR imaging including: T2-FSE, T1-SE and FLAIR sequences as well as quantitative magnetization transfer imaging. All the focal lesions were identified on T2-weighted images and were classified according to their signal hypointensity on T1-weighted scans. The white matter and MS lesions were segmented using a semi-automated system. MT ratio (MTR histogram analysis was performed for the brain white matter and the average MTR value was calculated for the classified MS lesions. Results: A significant reduction was found in MTR value of the normal appearing white matter (NAWM in patients with relapsing-remitting MS, suggesting that MS is a more diffuse disease, affecting the whole brain tissue. A wide range changes in MTR values can be observed in MS lesions. MTR reduction is correlated with the degree of lesion hypointensity on T1-weighted scans. The lower MTR values of lesions that appear progressively more hypointense on T1-weigted images reflect varying degrees of demyelination and

  6. On-chip tryptic digest with indirect coupling to ESI-MS using magnetic particles

    Czech Academy of Sciences Publication Activity Database

    Le Nel, A.; Křenková, Jana; Klepárník, Karel; Smadja, C.; Taverna, M.; Viovy, J.-L.; Foret, František

    2008-01-01

    Roč. 29, č. 24 (2008), s. 4944-4947 ISSN 0173-0835 R&D Projects: GA ČR(CZ) GA203/06/1685; GA AV ČR KAN400310651 Institutional research plan: CEZ:AV0Z40310501 Keywords : magnetic beads * MS * self-organization Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.509, year: 2008

  7. Spontaneous magnetic alignment by yearling snapping turtles: rapid association of radio frequency dependent pattern of magnetic input with novel surroundings.

    Science.gov (United States)

    Landler, Lukas; Painter, Michael S; Youmans, Paul W; Hopkins, William A; Phillips, John B

    2015-01-01

    We investigated spontaneous magnetic alignment (SMA) by juvenile snapping turtles using exposure to low-level radio frequency (RF) fields at the Larmor frequency to help characterize the underlying sensory mechanism. Turtles, first introduced to the testing environment without the presence of RF aligned consistently towards magnetic north when subsequent magnetic testing conditions were also free of RF ('RF off → RF off'), but were disoriented when subsequently exposed to RF ('RF off → RF on'). In contrast, animals initially introduced to the testing environment with RF present were disoriented when tested without RF ('RF on → RF off'), but aligned towards magnetic south when tested with RF ('RF on → RF on'). Sensitivity of the SMA response of yearling turtles to RF is consistent with the involvement of a radical pair mechanism. Furthermore, the effect of RF appears to result from a change in the pattern of magnetic input, rather than elimination of magnetic input altogether, as proposed to explain similar effects in other systems/organisms. The findings show that turtles first exposed to a novel environment form a lasting association between the pattern of magnetic input and their surroundings. However, under natural conditions turtles would never experience a change in the pattern of magnetic input. Therefore, if turtles form a similar association of magnetic cues with the surroundings each time they encounter unfamiliar habitat, as seems likely, the same pattern of magnetic input would be associated with multiple sites/localities. This would be expected from a sensory input that functions as a global reference frame, helping to place multiple locales (i.e., multiple local landmark arrays) into register to form a global map of familiar space.

  8. Spontaneous symmetry breaking and response functions

    International Nuclear Information System (INIS)

    Beraudo, A.; De Pace, A.; Martini, M.; Molinari, A.

    2005-01-01

    We study the quantum phase transition occurring in an infinite homogeneous system of spin 1/2 fermions in a non-relativistic context. As an example we consider neutrons interacting through a simple spin-spin Heisenberg force. The two critical values of the coupling strength-signaling the onset into the system of a finite magnetization and of the total magnetization, respectively-are found and their dependence upon the range of the interaction is explored. The spin response function of the system in the region where the spin-rotational symmetry is spontaneously broken is also studied. For a ferromagnetic interaction the spin response along the direction of the spontaneous magnetization occurs in the particle-hole continuum and displays, for not too large momentum transfers, two distinct peaks. The response along the direction orthogonal to the spontaneous magnetization displays instead, beyond a softened and depleted particle-hole continuum, a collective mode to be identified with a Goldstone boson of type II. Notably, the random phase approximation on a Hartree-Fock basis accounts for it, in particular for its quadratic-close to the origin-dispersion relation. It is shown that the Goldstone boson contributes to the saturation of the energy-weighted sum rule for ∼25% when the system becomes fully magnetized (that is in correspondence of the upper critical value of the interaction strength) and continues to grow as the interaction strength increases

  9. Spontaneous Development of Moral Concepts

    Science.gov (United States)

    Siegal, M.

    1975-01-01

    Moral competence is more difficult to attain than scientific competence. Since language comprehension plays a central role in conceptual development, and moral language is difficult to learn, there is a common deficiency in moral conceptual development. This suggests a theory of non-spontaneous solutions to moral problems. (Author/MS)

  10. Space-time resolved measurements of spontaneous magnetic fields in laser-produced plasma

    Czech Academy of Sciences Publication Activity Database

    Pisarczyk, T.; Gus’kov, S.Yu.; Dudžák, Roman; Chodukowski, T.; Dostál, Jan; Demchenko, N. N.; Korneev, Ph.; Kalinowska, Z.; Kalal, M.; Renner, Oldřich; Šmíd, Michal; Borodziuk, S.; Krouský, Eduard; Ullschmied, Jiří; Hřebíček, Jan; Medřík, Tomáš; Golasowski, Jiří; Pfeifer, Miroslav; Skála, Jiří; Pisarczyk, P.

    2015-01-01

    Roč. 22, č. 10 (2015), č. článku 102706. ISSN 1070-664X R&D Projects: GA MŠk LM2010014; GA MŠk(CZ) LD14089; GA ČR GPP205/11/P712 Grant - others:FP7(XE) 284464 Program:FP7 Institutional support: RVO:61389021 ; RVO:68378271 Keywords : space-time resolved spontaneous magnetic field (SMF) * Laser System Subject RIV: BL - Plasma and Gas Discharge Physics; BL - Plasma and Gas Discharge Physics (FZU-D) OBOR OECD: Fluids and plasma physics (including surface physics); Fluids and plasma physics (including surface physics) (FZU-D) Impact factor: 2.207, year: 2015 http://scitation.aip.org/content/aip/journal/pop/22/10/10.1063/1.4933364

  11. Spontaneous calf haematoma: case report.

    Science.gov (United States)

    Zubaidah, N H; Liew, N C

    2014-02-01

    Spontaneous calf haematoma is a rare condition and few case reports have been published in the English literature. Common conditions like deep vein thrombosis and traumatic gastrocnemius muscle tear need to be considered when a patient presents with unilateral calf swelling and tenderness. Ultrasound and Magnetic Resonance Imaging are essential for confirmation of diagnosis. The purpose of this paper is to report on a rare case of spontaneous calf hematoma and its diagnosis and management.

  12. Spontaneous nucleation and topological stabilization of skyrmions in magnetic nanodisks with the interfacial Dzyaloshinskii-Moriya interaction

    Science.gov (United States)

    Kolesnikov, A. G.; Samardak, A. S.; Stebliy, M. E.; Ognev, A. V.; Chebotkevich, L. A.; Sadovnikov, A. V.; Nikitov, S. A.; Kim, Yong Jin; Cha, In Ho; Kim, Young Keun

    2017-05-01

    One of the major societal challenges is reducing the power consumption of information technology (IT) devices and numerous data centers. Distinct from the current approaches based on switching of magnetic single-domain nanostructures or on movement of domain walls under high currents, an original magnetic skyrmion technology offers ultra-low power, fast, high-density, and scalable spintronic devices, including non-volatile random access memory. Using data-driven micromagnetic simulations, we demonstrate the possibility of spontaneous nucleation and stabilization of different skyrmionic states, such as skyrmions, merons, and meron-like configurations, in heavy metal/ferromagnetic nanodisks with the interfacial Dzyaloshinskii-Moriya interaction (iDMI) as a result of quasi-static magnetization reversal only. Since iDMI is not easily modulated in real systems, we show that skyrmion stabilization is easily achievable by manipulating magnetic anisotropy, saturation magnetization, and the diameters of nanodisks. The state diagrams, presented in terms of the topological charge, allow to explicitly distinguish the intermediate states between skyrmions and merons and can be used for developing a skyrmionic medium, which has been recently proposed to be a building block for future spin-orbitronic devices.

  13. Spontaneous nucleation and topological stabilization of skyrmions in magnetic nanodisks with the interfacial Dzyaloshinskii–Moriya interaction

    Energy Technology Data Exchange (ETDEWEB)

    Kolesnikov, A.G. [Laboratory of Thin Film Technologies, School of Natural Sciences, Far Eastern Federal University, Vladivostok 690950 (Russian Federation); Samardak, A.S., E-mail: samardak.as@dvfu.ru [Laboratory of Thin Film Technologies, School of Natural Sciences, Far Eastern Federal University, Vladivostok 690950 (Russian Federation); Stebliy, M.E.; Ognev, A.V.; Chebotkevich, L.A. [Laboratory of Thin Film Technologies, School of Natural Sciences, Far Eastern Federal University, Vladivostok 690950 (Russian Federation); Sadovnikov, A.V.; Nikitov, S.A. [Laboratory “Metamaterials,” Saratov State University, Saratov 410012 (Russian Federation); Kotel' nikov Institute of Radioengineering and Electronics, Russian Academy of Sciences, Moscow 125009 (Russian Federation); Kim, Yong Jin; Cha, In Ho [Department of Materials Science and Engineering, Korea University, Seoul 02841 (Korea, Republic of); Kim, Young Keun, E-mail: ykim97@korea.ac.kr [Department of Materials Science and Engineering, Korea University, Seoul 02841 (Korea, Republic of)

    2017-05-01

    One of the major societal challenges is reducing the power consumption of information technology (IT) devices and numerous data centers. Distinct from the current approaches based on switching of magnetic single-domain nanostructures or on movement of domain walls under high currents, an original magnetic skyrmion technology offers ultra-low power, fast, high-density, and scalable spintronic devices, including non-volatile random access memory. Using data-driven micromagnetic simulations, we demonstrate the possibility of spontaneous nucleation and stabilization of different skyrmionic states, such as skyrmions, merons, and meron-like configurations, in heavy metal/ferromagnetic nanodisks with the interfacial Dzyaloshinskii–Moriya interaction (iDMI) as a result of quasi-static magnetization reversal only. Since iDMI is not easily modulated in real systems, we show that skyrmion stabilization is easily achievable by manipulating magnetic anisotropy, saturation magnetization, and the diameters of nanodisks. The state diagrams, presented in terms of the topological charge, allow to explicitly distinguish the intermediate states between skyrmions and merons and can be used for developing a skyrmionic medium, which has been recently proposed to be a building block for future spin-orbitronic devices.

  14. Simulation investigation of storage ring optical klystron spontaneous emission

    International Nuclear Information System (INIS)

    Xu Hongliang; Liu Jinying; He Duohui; Diao Caozheng; Jia Qika; Sun Baogen

    1998-01-01

    The spontaneous emission of TOK in Hefei storage ring was simulated with Monte Carlo method. Section one described the structure of the permanent magnet TOK and the magnet field of TOK. Section two simulated results, and simulated results illustrated how the energy spread and emittance of electron beam impose on the spectrum of spontaneous emission. And with help of simulated results, the causes of small modulation factor which was measured by experiment was discussed

  15. Spontaneous drainage in syringomyelia: magnetic resonance imaging findings

    International Nuclear Information System (INIS)

    Bogdanov, E.I.; Mendelevich, E.G.; Ibatullin, M.M.

    2000-01-01

    We present five cases of syringomyelia associated with Chiari I or other causes of partial obstructions at the cervicomedullary junction, with spontaneous disruption of the wall of a cervical syrinx and formation of a communication between the cavity and the subarachnoid space, shown on axial MRI. MRI can be used to investigate the hydrodynamics, showing the liquid inside the disrupted syrinx wall and the pathway of drainage. The finding of spontaneous drainage may be important for understanding the pathogenesis of syringomyelia and may be helpful for choosing a surgical approach. (orig.)

  16. Spontaneous drainage in syringomyelia: magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Bogdanov, E.I.; Mendelevich, E.G. [Kazan State Medical Univ. (Russian Federation). Dept. of Neurology and Rehabilitation; Ibatullin, M.M. [Republic Medical Diagnostic Centre of Tatarstan, Kazan (Russian Federation). Department of Radiology

    2000-09-01

    We present five cases of syringomyelia associated with Chiari I or other causes of partial obstructions at the cervicomedullary junction, with spontaneous disruption of the wall of a cervical syrinx and formation of a communication between the cavity and the subarachnoid space, shown on axial MRI. MRI can be used to investigate the hydrodynamics, showing the liquid inside the disrupted syrinx wall and the pathway of drainage. The finding of spontaneous drainage may be important for understanding the pathogenesis of syringomyelia and may be helpful for choosing a surgical approach. (orig.)

  17. Role of magnetic resonance imaging in the diagnosis of spontaneous spondylodiscitis

    International Nuclear Information System (INIS)

    Cusmano, F.; Calabrese, G.; Bassi, S.; Branislav, S.; Bassi, P.

    2000-01-01

    Purpose of this work is to report the Magnetic Resonance Imaging (MRI) features of acute and chronic spontaneous spondylodiscitis as well as any as well as any typical patterns which can be useful for the differential diagnosis between pyogenic and tuberculous forms. Eleven patients affected with spontaneous spondylodiscitis were selected for the study; they were 7 men and 4 women ranging in age 33-87 years (mean: 64). Patients with a superconductive magnet at 1.5, with the following sequences: sagittal PD and T2-weighted TSE, sagittal T1-weighted SE, axial PD and T2-weighted TSE for the lumbar spine, axial T2-weighted GRE for the cervical and dorsal spine and axial and sagittal T1-weighted SE after contrast agent (gadolinium DTPA) injection. MR images were reviewed by three experienced radiologists and morphological and signal intensity changes of vertebral body and disk were recorded on a standard form. In 9 patients it was possible to compare MR to CT findings. Three patients had infectious diseases in other organs and 2 were diabetics. Biopsy was performed in two cases only and demonstrated Staphylococcus aureus in one and Mycobacterium tuberculosis in the other patient. MRI, allowed the correct diagnosis to be made in all cases, demonstrating the pathological involvement of the paravertebral structures and into the spinal canal earlier and more accurately than CT. A common finding in pyogenic and tuberculous spondylodiscitis was the low signal of the subcortical bone marrow on T1-weighted sagittal images, which enhanced after Gd-DTPA administration and became intermediate or high on T2-weighted images. Moreover, the steady high signal intensity of the disk on T2-weighted images and its contrast enhancement on T1-weighted images is typical for an acute inflammatory process. Based on our personal experience an literature data, it is believed that MRI is the most sensitive technique for the diagnosis of spondylodiscitis in the acute phase, whereas it is

  18. Magnetic and superconducting properties of Ir-doped EuFe2As2

    International Nuclear Information System (INIS)

    B Paramanik, U; Hossain, Z; L Paulose, P; Ramakrishnan, S; K Nigam, A; Geibel, C

    2014-01-01

    The magnetic and superconducting properties of 14% Ir-doped EuFe 2 As 2 are studied by means of dc and ac magnetic susceptibilities, electrical resistivity, specific heat and 151 Eu and 57 Fe Mössbauer spectroscopy (MS) measurements. Doping of Ir in EuFe 2 As 2 suppresses the Fe spin density wave transition and in turn gives rise to high temperature superconductivity below 22.5 K with a reentrant feature at lower temperature. Magnetization and 151 Eu Mössbauer data indicate that the Eu 2+ spins order magnetically below 18 K. 57 Fe MS studies show a line broadening in the absorption spectra below 18 K due to transferred hyperfine field from the magnetically ordered Eu sublattices. A pronounced λ-shape peak in the specific heat supports a second-order phase transition of Eu 2+ magnetic ordering with a strong ferromagnetic component, as confirmed by the magnetic field dependences of the transition. For a single crystal, the in-plane resistivity (ρ ab ) and out-of-plane susceptibility (χ c ) show superconducting transitions with zero resistance and diamagnetism, respectively. But the in-plane susceptibility (χ ab ) does not show any diamagnetic shielding against external fields. The observed non-zero resistance in the temperature range 10–17.5 K, below the superconducting transition temperature, suggests the possible existence of a spontaneous vortex state in this superconductor. (papers)

  19. Galvanic manifestation of spontaneous coherence in the negative glow

    International Nuclear Information System (INIS)

    Zhechev, D; Parvanova, N

    2002-01-01

    Both the magnetic depolarization of the spontaneous emission from self-aligned states and the discharge galvanic reaction are measured simultaneously in a magnetic field. The observed galvanic peak is ascribed to magnetic destruction of self-aligned ensembles of atoms. This presents galvanic manifestation of coherent conductivity. (letter to the editor)

  20. Measurements of Hk and Ms in thin magnetic films by the angular dependence of the planar Hall effect

    Science.gov (United States)

    Vatskicheva, M.; Vatskichev, L.

    1987-11-01

    It is shown that the angular dependences of the planar Hall effect measured with infinite magnetic field and with magnetic field H⩾ Hk have an intersection point and this fact is enough for measuring the anisotropy field Hk applying the method presented by Pastor, Ferreiro and Torres in J. Magn. Magn. Mat. 53 (1986) 349, 62 (1986) 101. The scaling of the Hall tension U proportional to M2s in mV/Am -1 gives a possibility for calculating the Ms-values of the films. These assumptions are verified for NiFe- and NiFeGe films with a uniaxial magnetic anisotropy.

  1. Spontaneous magnetic fluctuations and collisionless regulation of the Earth's plasma sheet

    Science.gov (United States)

    Moya, P. S.; Espinoza, C.; Stepanova, M. V.; Antonova, E. E.; Valdivia, J. A.

    2017-12-01

    Even in the absence of instabilities, plasmas often exhibit inherent electromagnetic fluctuations which are present due to the thermal motion of charged particles, sometimes called thermal (quasi-thermal) noise. One of the fundamental and challenging problems of laboratory, space, and astrophysical plasma physics is the understanding of the relaxation processes of nearly collisionless plasmas, and the resultant state of electromagnetic plasma turbulence. The study of thermal fluctuations can be elegantly addressed by using the Fluctuation-Dissipation Theorem that describes the average amplitude of the fluctuations through correlations of the linear response of the media with the perturbations of the equilibrium state (the dissipation). Recently, it has been shown that solar wind plasma beta and temperature anisotropy observations are bounded by kinetic instabilities such as the ion cyclotron, mirror, and firehose instabilities. The magnetic fluctuations observed within the bounded area are consistent with the predictions of the Fluctuation-Dissipation theorem even far below the kinetic instability thresholds, with an enhancement of the fluctuation level near the thresholds. Here, for the very first time, using in-situ magnetic field and plasma data from the THEMIS spacecraft, we show that such regulation also occurs in the Earth's plasma sheet at the ion scales and that, regardless of the clear differences between the solar wind and the magnetosphere environments, spontaneous fluctuation and their collisionless regulation seem to be fundamental features of space and astrophysical plasmas, suggesting the universality of the processes.

  2. Determining Ms temperature on a AISI D2 cold work tool steel using magnetic Barkhausen noise

    Energy Technology Data Exchange (ETDEWEB)

    Huallpa, Edgar Apaza, E-mail: gared1@gmail.com [Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes 2463, 05508-030 SP (Brazil); Sánchez, J. Capó, E-mail: jcapo@usp.br [Departamento de Física, Facultad de Ciencias Naturales, Universidad de Oriente, Av. Patricio Lumumba s/n 90500, Santiago de Cuba (Cuba); Padovese, L.R., E-mail: lrpadove@usp.br [Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes 2463, 05508-030 SP (Brazil); Goldenstein, Hélio, E-mail: hgoldens@usp.br [Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes 2463, 05508-030 SP (Brazil)

    2013-11-15

    Highlights: ► MBN was used to follow the martensite transformation in a tool steel. ► The results were compared with resistivity experiments. ► The Ms was estimated with Andrews equation coupled to ThermoCalc calculations. The experimental results showed good agreement. -- Abstract: The use of Magnetic Barkhausen Noise (MBN) as a experimental method for measuring the martensite start (Ms) temperature was explored, using as model system a cold-work tool steel (AISI D2) austenitized at a very high temperature (1473 K), so as to transform in sub-zero temperatures. The progress of the transformation was also followed with electrical resistance measurements, optical microscopy and scanning electron microscopy. Both MBN and resistivity measurements showed a change near 230 K during cooling, corresponding to the Ms temperature, as compared with 245 K, estimated with Andrews empirical equation applied to the austenite composition calculated using ThermoCalc.

  3. Properties of a magnetic superconductor with weak magnetization-application to ErNi2B2C

    International Nuclear Information System (INIS)

    Ng, T.K.; Leung, W.T.

    2001-01-01

    Using a Ginsburg-Landau free-energy functional, we study the H-T phase diagram of a weak magnetic superconductor, where the magnetization from the magnetic component is marginal in supporting a spontaneous vortex phase. In particular, the competition between the spiral state and spontaneous vortex phase is analysed. Our theory is applied to understand the magnetic properties of ErNi 2 B 2 C. (orig.)

  4. Spontaneous synthesis of gold nanoparticles on gum arabic-modified iron oxide nanoparticles as a magnetically recoverable nanocatalyst.

    Science.gov (United States)

    Wu, Chien-Chen; Chen, Dong-Hwang

    2012-06-19

    A novel magnetically recoverable Au nanocatalyst was fabricated by spontaneous green synthesis of Au nanoparticles on the surface of gum arabic-modified Fe3O4 nanoparticles. A layer of Au nanoparticles with thickness of about 2 nm was deposited on the surface of gum arabic-modified Fe3O4 nanoparticles, because gum arabic acted as a reducing agent and a stabilizing agent simultaneously. The resultant magnetically recoverable Au nanocatalyst exhibited good catalytic activity for the reduction of 4-nitrophenol with sodium borohydride. The rate constants evaluated in terms of pseudo-first-order kinetic model increased with increase in the amount of Au nanocatalyst or decrease in the initial concentration of 4-nitrophenol. The kinetic data suggested that this catalytic reaction was diffusion-controlled, owing to the presence of gum arabic layer. In addition, this nanocatalyst exhibited good stability. Its activity had no significant decrease after five recycles. This work is useful for the development and application of magnetically recoverable Au nanocatalyst on the basis of green chemistry principles.

  5. Spontaneous synthesis of gold nanoparticles on gum arabic-modified iron oxide nanoparticles as a magnetically recoverable nanocatalyst

    Science.gov (United States)

    2012-01-01

    A novel magnetically recoverable Au nanocatalyst was fabricated by spontaneous green synthesis of Au nanoparticles on the surface of gum arabic-modified Fe3O4 nanoparticles. A layer of Au nanoparticles with thickness of about 2 nm was deposited on the surface of gum arabic-modified Fe3O4 nanoparticles, because gum arabic acted as a reducing agent and a stabilizing agent simultaneously. The resultant magnetically recoverable Au nanocatalyst exhibited good catalytic activity for the reduction of 4-nitrophenol with sodium borohydride. The rate constants evaluated in terms of pseudo-first-order kinetic model increased with increase in the amount of Au nanocatalyst or decrease in the initial concentration of 4-nitrophenol. The kinetic data suggested that this catalytic reaction was diffusion-controlled, owing to the presence of gum arabic layer. In addition, this nanocatalyst exhibited good stability. Its activity had no significant decrease after five recycles. This work is useful for the development and application of magnetically recoverable Au nanocatalyst on the basis of green chemistry principles. PMID:22713480

  6. Molecular mapping of MS-cd 1 gene in Chinese kale | Zhang ...

    African Journals Online (AJOL)

    A dominant male sterility (DGMS) line 79-399-3 was developed from spontaneous mutation in Brassica oleracea var. capitata and has been widely used in the production of hybrid cultivar in China. In this line, male sterility is controlled by a dominant gene Ms-cd1. In the present study, primary mapping of Ms-cd1 was ...

  7. Magnetic studies in evaporated Ni/Pd multilayers

    International Nuclear Information System (INIS)

    Chafai, K.; Salhi, H.; Lassri, H.; Yamkane, Z.; Lassri, M.; Abid, M.; Hlil, E.K.; Krishnan, R.

    2011-01-01

    The magnetic properties of Ni/Pd multilayers, prepared by sequential evaporation in ultrahigh vacuum, have been studied. The Ni thickness dependence of the magnetization and magnetic anisotropy is discussed. The temperature dependence of the spontaneous magnetization is well described by a T 3/2 law in all multilayers. A spin-wave theory has been used to explain the temperature dependence of the spontaneous magnetization, and the approximate values for the exchange interactions for various Ni layer thicknesses have been obtained. - Research highlights: → The magnetic properties of Ni/Pd multilayers, prepared by sequential evaporation in ultrahigh vacuum, have been studied. → The temperature dependence of the spontaneous magnetization is well described by a T 3/2 law in Ni/Pd multilayers. → The spin-wave constant B was observed to depend on t Ni nonmonotonically. → A spin-wave theory has been used to explain the temperature dependence of the spontaneous magnetization. → The approximate values for the exchange interactions for various Ni layer thicknesses have been obtained.

  8. Magnetic order of Au nanoparticle with clean surface

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Ryuju; Ishikawa, Soichiro; Sato, Hiroyuki; Sato, Tetsuya, E-mail: satoh@appi.keio.ac.jp

    2015-11-01

    Au nanoparticles, which are kept in vacuum after the preparation by gas evaporation method, show ferromagnetism even in 1.7 nm in diameter. The intrinsic magnetism is examined by detecting the disappearance of spontaneous magnetization in Au bulk prepared by heating the nanoparticles without exposure to the air. The temperature dependence of spontaneous magnetization is not monotonic and the increase in magnetization is observed after Au nanoparticles are exposed to the air. The magnetic behavior can be interpreted by the ferrimagnetic-like core–shell structure with shell thickness of 0.16±0.01 nm and magnetic moment of (1.5±0.1)×10{sup −2} μ{sub B}/Au atom, respectively. - Highlights: • Au nanoparticles with clean surface were prepared by the gas evaporation method. • The spontaneous magnetization was observed in Au nanoparticles. • Temperature dependent spontaneous magnetization of smaller Au particles was not monotonic. • The magnetic behavior was interpreted by the ferrimagnetic-like core–shell model. • The shell thickness and the magnetic moment per Au atom were estimated.

  9. Spontaneous lateral sphenoid cerebrospinal fluid fistula: MRI diagnosis

    Directory of Open Access Journals (Sweden)

    Matthew Goodier

    2012-02-01

    Full Text Available Spontaneous or primary cerebrospinal fluid (CSF fistula is a rare cause of CSF rhinorrhoea. Magnetic resonance imaging with high resolution highly T2-weighted images is valuable in preoperative localisation and characterisation of the defect particularly if a transnasal endoscopic approach is planned. This report describes the radiological evaluation and surgical management of a 53 year old male who presented with a spontaneous lateral sphenoid CSF fistula.

  10. Determination of Organophosphorous Pesticides in Environmental Water Samples Using Surface-Engineered C18 Functionalized Silica-Coated Core-Shell Magnetic Nanoparticles-Based Extraction Coupled with GC-MS/MS Analysis.

    Science.gov (United States)

    Srivastava, Neha; Kumari, Supriya; Nair, Kishore; Alam, Samsul; Raza, Syed K

    2017-05-01

    The present paper depicts a novel method based on magnetic SPE (MSPE) for the determination of organophosphorus pesticides (OPs) such as phorate, malathion, and chlorpyrifos in environmental water samples. In this study, C18 functionalized silica-coated core-shell iron oxide magnetic nanoparticles (MNPs) were used as a surface-engineered magnetic sorbent for the selective extraction of pesticides from aqueous samples, followed by GC-MS and GC-tandem MS analysis for confirmative determination of the analytes. Various important method parameters, including quantity of MNP adsorbent, volume of sample, effective time for extraction, nature of the desorbing solvent, and pH of the aqueous sample, were investigated and optimized to obtain maximum method performance. Under the optimized instrumental analysis conditions, good linearity (r2 value ≥0.994) was achieved at the concentration range of 0.5-500 μg/L. Recoveries were in the range of 79.2-96.3 and 80.4-97.5% in selective-ion monitoring and multiple reaction monitoring (MRM) modes, respectively, at the spiking concentrations of 1, 5, and 10 μg/L. MRM mode showed better sensitivity, selectivity, and low-level detection (0.5 μg/L) of analytes. The novel MSPE method is a simple, cheap, rapid, and eco-friendly method for the determination of OPs in environmental water samples.

  11. The Spontaneous Combustion of Railway Ties and Asphalt Shingles

    Science.gov (United States)

    Leslie, Geoffrey

    Many Low Carbon Fuels (LCFs) present unknown spontaneous combustion risks, which must be quantified before their use as fossil fuel replacements. Wood and coal spontaneous combustion is well understood; however, LCFs weather, and subsequent chemical changes could affect their spontaneous combustion properties. LCF spontaneous combustion could lead to accidental fires with possible loss of life, limb and property. The spontaneous combustion risks of two LCFs, discarded creosote-treated wooden railway ties and roofing asphalt shingles, were investigated with calorimetry and heat transfer experiments. Chemical changes due to weathering were studied with pyrolysis-Gas Chromatography/Mass Spectrometry (py-GC/MS). Creosote-treated wooden railway tie dust, roofing asphalt shingle particles, poplar wood pellets, and petroleum coke self-heating were studied with isothermal calorimetry. Railway tie dust and asphalt shingle heat transfer were characterized with a guarded hot plate. Petroleum coke self-heating was consistent with coal, while both poplar pellets and railway tie dust were found to be more reactive compared to oven test results of similar materials. The observed increase in reactivity was probably a result of significant moisture contenint in the pellet and railway tie dust. Critical conditions for spontaneous combustion were evaluated with the Frank-Kamenetskii parameter, assuming an ambient temperature of 40°C and constant moisture content. Kamenetskii calculations indicate that a 1.6 m cube of railway tie dust, or a 58 m cube of asphalt particles, would be unstable and combust. LCF chemistry may have been affected by weathering, which would cause chemical changes that affect their spontaneous combustion properties. Therefore, railway tie wood and roofing asphalt shingle chemistry were investigated by identifying products of 250° and 550°C pyrolysis with py-GC/MS. Railway tie wood pyrolyzates did not show signs of weathering; in contrast, asphalt pyrolysis

  12. Magnetophoretic separation ICP-MS immunoassay using Cs-doped multicore magnetic nanoparticles for the determination of salmonella typhimurium.

    Science.gov (United States)

    Jeong, Arong; Lim, H B

    2018-02-01

    In this work, a magnetophoretic separation ICP-MS immunoassay using newly synthesized multicore magnetic nanoparticles (MMNPs) was developed for the determination of salmonella typhimurium (typhi). The uniqueness of this method was the use of MMNPs doped with Cs for both separation and detection, which enable us to achieve fast analysis, high sensitivity, and good reliability. For demonstration, heat-killed typhi in a phosphate buffer solution was determined by ICP-MS after the MMNP-typhi reaction product was separated from unreacted MMNPs in a micropipette tip filled with 25% polyethylene glycol through magnetophoretic separation. The calibration curve obtained by plotting 133 Cs intensity vs. the number of synthetic standard, showed a coefficient of determination (R 2 ) of 0.94 with a limit of detection (LOD) of 102 cells/mL without cell culturing. Excellent recoveries, between 98-100%, were obtained from four replicates and compared with a sandwich-type ICP-MS immunoassay for further confirmation. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Acupuncture and Spontaneous Regression of a Radiculopathic Cervical Herniated Disc

    Directory of Open Access Journals (Sweden)

    Kim Sung-Ha

    2012-06-01

    Full Text Available The spontaneous regression of herniated cervical discs is not a well-established phenomenon. However, we encountered a case of a spontaneous regression of a severe radiculopathic herniated cervical disc that was treated with acupuncture, pharmacopuncture, and herb medicine. The symptoms were improved within 12 months of treatment. Magnetic resonance imaging (MRI conducted at that time revealed marked regression of the herniated disc. This case provides an additional example of spontaneous regression of a herniated cervical disc documented by MRI following non-surgical treatment.

  14. Spontaneous Scalarization: Dead or Alive?

    Science.gov (United States)

    Berti, Emanuele; Crispino, Luis; Gerosa, Davide; Gualtieri, Leonardo; Horbatsch, Michael; Macedo, Caio; Okada da Silva, Hector; Pani, Paolo; Sotani, Hajime; Sperhake, Ulrich

    2015-04-01

    In 1993, Damour and Esposito-Farese showed that a wide class of scalar-tensor theories can pass weak-field gravitational tests and exhibit nonperturbative strong-field deviations away from General Relativity in systems involving neutron stars. These deviations are possible in the presence of ``spontaneous scalarization,'' a phase transition similar in nature to spontaneous magnetization in ferromagnets. More than twenty years after the original proposal, binary pulsar experiments have severely constrained the possibility of spontaneous scalarization occurring in nature. I will show that these experimental constraints have important implications for the torsional oscillation frequencies of neutron stars and for the so-called ``I-Love-Q'' relations in scalar-tensor theories. I will also argue that there is still hope to observe strong scalarization effects, despite the strong experimental bounds on the original mechanism. In particular, I will discuss two mechanisms that could produce strong scalarization in neutron stars: anisotropy and multiscalarization. This work was supported by NSF CAREER Award PHY-1055103.

  15. Linkage mapping of a dominant male sterility gene Ms-cd1 in Brassica oleracea

    NARCIS (Netherlands)

    Wang, X.; Lou, P.; Bonnema, A.B.; Yang, Boujun; He, H.; Zhang, Y.; Fang, Z.

    2005-01-01

    The dominant male sterility gene Ms-cd1 (c, cabbage; d, dominant) was identified as a spontaneous mutation in the spring cabbage line 79-399-3. The Ms-cd1 gene is successfully applied in hybrid seed production of several Brassica oleracea cultivars in China. Amplified fragment length polymorphism

  16. Effects of microstructures on the performance of rare-earth-free MnBi magnetic materials and magnets

    Science.gov (United States)

    Nguyen, Vuong Van; Nguyen, Truong Xuan

    2018-03-01

    Since the solidification of MnBi alloys is peritectic, their microstructures always consist of the starting phases of Mn and Bi and the productive phase MnBi. The high performance of MnBi bulk magnets requires appropriate routes of preparing MnBi powders of high spontaneous magnetization Ms and large coercivity iHc as well a route of producing bulk magnets thereof. In these routes, the microstructures of arc-melted alloys, annealed alloys and magnets strongly related to the quality of powders and the performance of magnets. The paper proves that: i) The microstructure of fine Mn-inclusions embedded in the matrix of Bi is preferred for arc-melted alloys to realize the rapid evolution of the ferromagnetic phase inside them during their sequent annealing process; ii) The time-controlled annealing process plays a key role in controlling the microstructure with the main ferromagnetic phase matrix, in which the rest of Mn and the Bi accumulations are embedded; iii) The cold (in-liquid-nitrogen) ball milling annealed alloys is required for preparing a high quality powders with the preferred sub-micrometer microstructure without a Bi-decomposition; iv) The short-time warm compaction is crucial to fabricate dense, highly textured bulk magnets with the micrometer microstructure. The realization and control of these preferred microstructures figured in these routes enhance the chance of preparing MnBi bulk magnets with the energy product (BH)max larger than 8 MGOe.

  17. Magneto-optics observation of spontaneous domain structure in ferromagnetic La0.78Ca0.22MnO3 single crystal

    International Nuclear Information System (INIS)

    Jung, G; Indenbom, M; Markovich, V; Beek, C J van der; Mogilyansky, D; Mukovskii, Ya M

    2004-01-01

    Spontaneous ferromagnetic domains in lightly Ca-doped La 1-x Ca x MnO 3 single crystals have been visualized and investigated by means of the magneto-optical technique. In marked difference to the magnetic contrast structures associated with magneto-crystalline anisotropy, which appear only in applied magnetic field, spontaneous ferromagnetic domains show up at low temperatures below the Curie temperature in zero applied field and are characterized by oppositely oriented spontaneous magnetization in adjacent domains. Ferromagnetic domains seen in zero field cooled samples take the form of almost periodic, corrugated stripe-like structures. Application of even a very weak magnetic field during cooling through the magnetic ordering transition changes the stripe domain structures into a bubble domain system

  18. Early Diagnosis of Irkut Virus Infection Using Magnetic Bead-Based Serum Peptide Profiling by MALDI-TOF MS in a Mouse Model

    Directory of Open Access Journals (Sweden)

    Nan Li

    2014-03-01

    Full Text Available Early diagnosis is important for the prompt post-exposure prophylaxis of lyssavirus infections. To diagnose Irkut virus (IRKV infection during incubation in mice, a novel method using magnetic bead-based serum peptide profiling by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS has been established. For this test, serum peptides were concentrated by adsorption to and elution from the magnetic bead-based weak cation ion exchanger. Mass spectrograms obtained by MALDI-TOF MS were analyzed using ClinProTools bioinformatics software. Construction of the diagnostic model was performed using serum samples from mice infected with IRKV and rabies virus (RABV BD06, Flury-LEP, and SRV9 (as controls. The method accurately diagnosed sera 2, 4 and 8 days after IRKV and RABV infections. The sensitivity, specificity, and total accuracy of diagnosis were 86.7%, 95.2%, and 92.9%, respectively. However, IRKV could not be differentiated from RABV 1 day after infection. The results of the present study indicate that serum peptide profiling by MALDI-TOF MS is a promising technique for the early clinical diagnosis of lyssavirus infections and needs to be further tested in humans and farm animals.

  19. Dynamic changes of intramural hematoma in patients with acute spontaneous internal carotid artery dissection.

    Science.gov (United States)

    Heldner, Mirjam R; Nedelcheva, Mila; Yan, Xin; Slotboom, Johannes; Mathier, Etienne; Hulliger, Justine; Verma, Rajeev K; Sturzenegger, Matthias; Jung, Simon; Bernasconi, Corrado; Arnold, Marcel; Wiest, Roland; Fischer, Urs

    2015-08-01

    We prospectively investigated temporal and spatial evolution of intramural hematomas in patients with acute spontaneous internal carotid artery dissection using repeated magnetic resonance imaging over six-months. The aim of the present study was to assess dynamic changes of intramural hematoma in patients with acute spontaneous internal carotid artery dissection at multiple follow-up time-points with T1w, PD/T2w, and magnetic resonance angiography. We performed serial multiparametric magnetic resonance imaging in 10 patients with spontaneous internal carotid artery dissection on admission, at days 1, 3, 7-14 and at months 1·5, 3, and 6. We calculated the volume and extension of the hyperintense intramural hematoma using T1w and PD/T2w fat suppressed sequences and assessed the degree of stenosis due to the hematoma using magnetic resonance angiography. Mean interval from symptom onset to first magnetic resonance imaging was two-days (SD 2·7). Two patients presented with ischemic stroke, three with transient ischemic attacks, and five with pain and local symptoms only. Nine patients had a transient increase of the intramural hematoma volume, mainly up to day 10 after symptom onset. Fifty percent had a transient increase in the degree of the internal carotid artery stenosis on MRA, one resulting in a temporary occlusion. Lesions older than one-week were predominantly characterized by a shift from iso- to hyperintese signal on T2w images. At three-month follow-up, intramural hematoma was no longer detectable in 80% of patients and had completely resolved in all patients after six-months. Spatial and temporal dynamics of intramural hematomas after spontaneous internal carotid artery dissection showed an early volume increase with concomitant progression of the internal carotid artery stenosis in 5 of 10 patients. Although spontaneous internal carotid artery dissection overall carries a good prognosis with spontaneous hematoma resorption in all our patients, early

  20. Dorsomedial prefontal cortex supports spontaneous thinking per se.

    Science.gov (United States)

    Raij, T T; Riekki, T J J

    2017-06-01

    Spontaneous thinking, an action to produce, consider, integrate, and reason through mental representations, is central to our daily experience and has been suggested to serve crucial adaptive purposes. Such thinking occurs among other experiences during mind wandering that is associated with activation of the default mode network among other brain circuitries. Whether and how such brain activation is linked to the experience of spontaneous thinking per se remains poorly known. We studied 51 healthy subjects using a comprehensive experience-sampling paradigm during 3T functional magnetic resonance imaging. In comparison with fixation, the experiences of spontaneous thinking and spontaneous perception were related to activation of wide-spread brain circuitries, including the cortical midline structures, the anterior cingulate cortex and the visual cortex. In direct comparison of the spontaneous thinking versus spontaneous perception, activation was observed in the anterior dorsomedial prefrontal cortex. Modality congruence of spontaneous-experience-related brain activation was suggested by several findings, including association of the lingual gyrus with visual in comparison with non-verbal-non-visual thinking. In the context of current literature, these findings suggest that the cortical midline structures are involved in the integrative core substrate of spontaneous thinking that is coupled with other brain systems depending on the characteristics of thinking. Furthermore, involvement of the anterior dorsomedial prefrontal cortex suggests the control of high-order abstract functions to characterize spontaneous thinking per se. Hum Brain Mapp 38:3277-3288, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  1. Magnetic sulfur-doped porous carbon for preconcentration of trace mercury in environmental water prior to ICP-MS detection.

    Science.gov (United States)

    Peng, Chuyu; He, Man; Chen, Beibei; Huang, Lijin; Hu, Bin

    2017-11-20

    A novel magnetic sulfur-doped porous carbon (MSPC) was fabricated via a simple one-step carbonization of a mixture of sucrose, basic magnesium sulfate whiskers and Fe 3 O 4 @SiO 2 nanoparticles. Due to the high S content, the prepared MSPC possessed high adsorption capacity for Hg 2+ (343 mg g -1 ) with good selectivity. Based on this, a method coupling magnetic solid phase extraction (MSPE) with inductively coupled plasma mass spectrometry (ICP-MS) was developed for the determination of trace Hg 2+ in environmental water samples. Various parameters such as pH, desorption solvent and its concentration, desorption volume and time, sample volume, and adsorption time that affect the determination have been optimized. Under the optimal conditions, a high enrichment factor of 100-fold was obtained, the limit of detection (LOD) was found to be 0.52 pg mL -1 with a relative standard deviation (c = 10 pg mL -1 , n = 7) of 7.1%, and a good linearity was obtained within the concentration range of 2-5000 pg mL -1 for Hg 2+ . Besides, the proposed method has very fast adsorption/desorption kinetics, target Hg 2+ could be rapidly adsorbed on the prepared MSPC in 2 min and desorbed from the MSPC in 2 min with the assistance of a permanent magnet. Therefore, the proposed method of MSPE-ICP-MS exhibits good application potential in the determination of trace Hg 2+ in environmental water samples.

  2. Non-enzymolytic adenosine barcode-mediated dual signal amplification strategy for ultrasensitive protein detection using LC-MS/MS.

    Science.gov (United States)

    Yang, Wen; Li, Tengfei; Shu, Chang; Ji, Shunli; Wang, Lei; Wang, Yan; Li, Duo; Mtalimanja, Michael; Sun, Luning; Ding, Li

    2018-05-10

    A method is described for the determination of proteins with LC-MS/MS enabled by a small molecule (adenosine) barcode and based on a double-recognition sandwich structure. The coagulation protein thrombin was chosen as the model analyte. Magnetic nanoparticles were functionalized with aptamer29 (MNP/apt29) and used to capture thrombin from the samples. MNP/apt29 forms a sandwich with functionalized gold nanoparticles modified with (a) aptamer15 acting as thrombin-recognizing element and (b) a large number of adenosine as mass barcodes. The sandwich formed (MNP/apt29-thrombin-apt15/AuNP/adenosine) can ben magnetically separated from the sample. Mass barcodes are subsequently released from the sandwiched structure for further analysis by adding 11-mercaptoundecanoic acid. Adenosine is then detected by LC-MS/MS as it reflects the level of thrombin with impressively amplified signal. Numerous adenosines introduced into the sandwich proportional to the target concentration further amplify the signal. Under optimized conditions, the response is linearly proportional to the thrombin concentration in the range of 0.02 nM to 10 nM, with a detection limit of 9 fM. The application of this method to the determination of thrombin in spiked plasma samples gave recoveries that ranged from 92.3% to 104.7%. Graphical abstract Schematic representation of a method for the determination of thrombin with LC-MS/MS. The method is based on a double-recognition sandwiched structure. With LC-MS/MS, mass barcodes (adenosine) are detected to quantify thrombin, which amplifies the detection signal impressively.

  3. Structural, kinetic, and thermodynamic characterization of the interconverting isomers of MS-325, a gadolinium(III)-based magnetic resonance angiography contrast agent.

    Science.gov (United States)

    Tyeklar, Zoltan; Dunham, Stephen U; Midelfort, Katarina; Scott, Daniel M; Sajiki, Hirano; Ong, Karen; Lauffer, Randall B; Caravan, Peter; McMurry, Thomas J

    2007-08-06

    The amphiphilic gadolinium complex MS-325 ((trisodium-{(2-(R)-[(4,4-diphenylcyclohexyl) phosphonooxymethyl] diethylenetriaminepentaacetato) (aquo)gadolinium(III)}) is a contrast agent for magnetic resonance angiography (MRA). MS-325 comprises a GdDTPA core with an appended phosphodiester moiety linked to a diphenylcyclohexyl group to facilitate noncovalent binding to serum albumin and extension of the plasma half-life in vivo. The chiral DTPA ligand (R) was derived from L-serine, and upon complexation with gadolinium, forms two interconvertible diastereomers, denoted herein as isomers A and B. X-ray crystallography of the tris(ethylenediamine)cobalt(III) salt derivative of isomer A revealed a structure in the polar acentric space group P32. The structure consisted of three independent molecules of the gadolinium complex in the asymmetric unit along with three Delta-[Co(en)3]3+ cations, and it represents an unusual example of spontaneous Pasteur resolution of the cobalt cation. The geometry of the coordination core was best described as a distorted trigonal prism, and the final R factor was 5.6%. The configuration of the chiral central nitrogen of the DTPA core was S. The Gd-water (2.47-2.48 A), the Gd-acetate oxygens (2.34-2.42 A), and the Gd-N bond distances (central N, 2.59-2.63 A; terminal N, 2.74-2.80 A) were similar to other reported GdDTPA structures. The structurally characterized single crystal was one of two interconvertable diastereomers (isomers A and B) that equilibrated to a ratio of 1.81 to 1 at pH 7.4 and were separable at elevated pH by ion-exchange chromatography. The rate of isomerization was highly pH dependent: k1 = (1.45 +/- 0.08) x 102[H+] + (4.16 +/- 0.30) x 105[H+]2; k-1 = (2.57 +/- 0.17) x 102[H+] + (7.54 +/- 0.60) x 105[H+]2.

  4. [Detection of serum proteins in the patients of lung adenocarcinoma by the method of magnetic bead based sample fractionation and MALDI-TOF-MS].

    Science.gov (United States)

    Liu, Dan; Liu, Lun-Xu; Yuan, Quan; Li, Xiao-Liang; Huang, Na; Yang, Xiao-Dong

    2010-05-01

    To screen the serum proteins related to human lung adenocarcinoma using matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) technology. The blood samples were collected from 10 patients of lung adenocarcinoma before and one week after the surgery, while 10 healthy subjects were used as control. The differential protein expression between the two groups and the change of those proteins after surgery were studied by ClinProt magnetic bead enrichment and MALDI-TOF-MS. Six protein peaks were identified, 2 of them were highly expressed protein biomarkers with relative molecular weights of 2661, 2991, and increased after the surgery, 4 of them were lowly expressed protein biomarkers with relative molecular weights of 4091, 4210, 4644, 5336, which continuously decreased after the surgery. ClinProt magnetic bead enrichment and MALDI-TOF-MS is a quick, easy and sensitive method of proteomics. The differential expressed proteins may be the latent tumor marker of lung adenocarcinoma. The alteration of those proteins after surgery might be helpful to assess the therapeutic effect and prognosis.

  5. Magnetic Generation due to Mass Difference between Charge Carriers

    OpenAIRE

    Chen, Shi; Dan, JiaKun; Chen, ZiYu; Li, JianFeng

    2013-01-01

    The possibility of spontaneous magnetization due to the "asymmetry in mass" of charge carriers in a system is investigated. Analysis shows that when the masses of positive and negative charge carriers are identical, no magnetization is predicted. However, if the masses of two species are different, spontaneous magnetic field would appear, either due to the equipartition of magnetic energy or due to fluctuations together with a feedback mechanism. The conditions for magnetization to occur are ...

  6. Effect of Polyethylene Glycol on the Formation of Magnetic Nanoparticles Synthesized by Magnetospirillum magnetotacticum MS-1.

    Directory of Open Access Journals (Sweden)

    Hirokazu Shimoshige

    Full Text Available Magnetotactic bacteria (MTB synthesize intracellular magnetic nanocrystals called magnetosomes, which are composed of either magnetite (Fe3O4 or greigite (Fe3S4 and covered with lipid membranes. The production of magnetosomes is achieved by the biomineralization process with strict control over the formation of magnetosome membrane vesicles, uptake and transport of iron ions, and synthesis of mature crystals. These magnetosomes have high potential for both biotechnological and nanotechnological applications, but it is still extremely difficult to grow MTB and produce a large amount of magnetosomes under the conventional cultural conditions. Here, we investigate as a first attempt the effect of polyethylene glycol (PEG added to the culture medium on the increase in the yield of magnetosomes formed in Magnetospirillum magnetotacticum MS-1. We find that the yield of the formation of magnetosomes can be increased up to approximately 130 % by adding PEG200 to the culture medium. We also measure the magnetization of the magnetosomes and find that the magnetosomes possess soft ferromagnetic characteristics and the saturation mass magnetization is increased by 7 %.

  7. Stabilization of Rayleigh-Taylor instability due to the spontaneous magnetic field in laser produced plasma

    International Nuclear Information System (INIS)

    Ogasawara, Masatada; Takita, Masami.

    1981-08-01

    Spontaneous magnetic fields due to the temperature gradient nabla T 0 produced by a focussed laser beam on one point of a pellet are taken into account in deriving the dispersion relation of Rayleigh-Taylor instability. Growth rate γ decreases with time. Density fluctuation with wavelength shorter than 1.5(R/L sub(T)) x (n sub(s)/n 0 )sup(1/2) μm is remarkably stabilized, where R, L sub(T), n sub(s) and n 0 are the radius of a pellet, L sub(T)sup(-1) = + nabla T 0 /T 0 + , number densities of solid and the pellet. Validity condition of the theory is γt 0 >> 1 or in another form R >> L, where t 0 is the time of thermal expansion of a pellet and L -1 = + nabla n 0 /n 0 + . (author)

  8. Analysis of Spontaneous and Nerve-Evoked Calcium Transients in Intact Extraocular Muscles in Vitro

    Science.gov (United States)

    Feng, Cheng-Yuan; Hennig, Grant W.; Corrigan, Robert D.; Smith, Terence K.; von Bartheld, Christopher S.

    2012-01-01

    Extraocular muscles (EOMs) have unique calcium handling properties, yet little is known about the dynamics of calcium events underlying ultrafast and tonic contractions in myofibers of intact EOMs. Superior oblique EOMs of juvenile chickens were dissected with their nerve attached, maintained in oxygenated Krebs buffer, and loaded with fluo-4. Spontaneous and nerve stimulation-evoked calcium transients were recorded and, following calcium imaging, some EOMs were double-labeled with rhodamine-conjugated alpha-bungarotoxin (rhBTX) to identify EOM myofiber types. EOMs showed two main types of spontaneous calcium transients, one slow type (calcium waves with 1/2max duration of 2–12 s, velocity of 25–50 μm/s) and two fast “flash-like” types (Type 1, 30–90 ms; Type 2, 90–150 ms 1/2max duration). Single pulse nerve stimulation evoked fast calcium transients identical to the fast (Type 1) calcium transients. Calcium waves were accompanied by a local myofiber contraction that followed the calcium transient wavefront. The magnitude of calcium-wave induced myofiber contraction far exceeded those of movement induced by nerve stimulation and associated fast calcium transients. Tetrodotoxin eliminated nerve-evoked transients, but not spontaneous transients. Alpha-bungarotoxin eliminated both spontaneous and nerve-evoked fast calcium transients, but not calcium waves, and caffeine increased wave activity. Calcium waves were observed in myofibers lacking spontaneous or evoked fast transients, suggestive of multiply-innervated myofibers, and this was confirmed by double-labeling with rhBTX. We propose that the abundant spontaneous calcium transients and calcium waves with localized contractions that do not depend on innervation may contribute to intrinsic generation of tonic functions of EOMs. PMID:22579493

  9. Spontaneous violation of chiral symmetry in QCD vacuum is the origin of baryon masses and determines baryon magnetic moments and their other static properties

    International Nuclear Information System (INIS)

    Ioffe, B. L.

    2009-01-01

    A short review is presented of the spontaneous violation of chiral symmetry in QCD vacuum. It is demonstrated that this phenomenon is the origin of baryon masses in QCD. The value of nucleon mass is calculated, as well as the masses of hyperons and some baryonic resonances, and expressed mainly through the values of quark condensates - , q = u, d, s,-the vacuum expectation values (v.e.v.) of quark field. The concept of v.e.v. induced by external fields is introduced. It is demonstrated that such v.e.v. induced by static electromagnetic field results in quark condensate magnetic susceptibility, which plays the main role in determination of baryon magnetic moments. The magnetic moments of proton, neutron, and hyperons are calculated. The results of calculation of baryon octet β-decay constants are also presented.

  10. Synchrotron Diffraction Studies of Spontaneous Magnetostriction in Rare Earth Transition Metal Compounds

    International Nuclear Information System (INIS)

    Ning Yang

    2004-01-01

    Thermal expansion anomalies of R 2 Fe 14 B and R 2 Fe 17 C x (x = 0,2) (R Y, Nd, Gd, Tb, Er) stoichiometric compounds are studied with high-energy synchrotron X-ray powder diffraction using Debye-Schemer geometry in temperature range 10K to 1000K. Large spontaneous magnetostriction up to their Curie temperatures (T c ) is observed. The a-axes show relatively larger invar effects than c-axes in the R 2 Fe 14 B compounds whereas the R 2 Fe 17 C x show the contrary anisotropies. The iron sub-lattice is shown to dominate the spontaneous magnetostriction of the compounds. The contribution of the rare earth sublattice is roughly proportional to the spin magnetic moment of the rare earth in the R 2 Fe 14 B compounds but in R 2 Fe 17 C x , the rare earth sub-lattice contribution appears more likely to be dominated by the local bonding. The calculation of spontaneous magnetostrain of bonds shows that the bonds associated with Fe(j2) sites in R 2 Fe 14 B and the dumbbell sites in R 2 Fe 17 C x have larger values, which is strongly related to their largest magnetic moment and Wigner-Seitz atomic cell volume. The roles of the carbon atoms in increasing the Curie temperatures of the R 2 Fe 17 compounds are attributed to the increased separation of Fe hexagons. The R 2 Fe 17 and R 2 Fe 14 B phases with magnetic rare earth ions also show anisotropies of thermal expansion above T c . For R 2 Fe 17 and R 2 Fe 14 B the a a /a c > 1 whereas the anisotropy is reversed with the interstitial carbon in R 2 Fe 17 . The average bond magnetostrain is shown to be a possible predictor of the magnetic moment of Fe sites in the compounds. Both of the theoretical and phenomenological models on spontaneous magnetostriction are discussed and a Landau model on the spontaneous magnetostriction is proposed

  11. Pauses in spontaneous written communication: a keystroke logging study

    Directory of Open Access Journals (Sweden)

    Evgeny Chukharev-Hudilainen

    2014-06-01

    Full Text Available Spontaneous writing observed in chats, instant messengers, and social media has become established as productive modes of communication and discourse genres. However, they remain understudied from the perspective of writing process research. In this paper, we present an empirical study wherein keystrokes made by chat users in a game were recorded. The distributions of the inter-key intervals were analyzed and fitted with ex-Gaussian distribution equation, and an argument for psycholinguistic interpretation of the distribution parameters is presented. This analysis leads to establishing a threshold of 500 ms for the identification of pauses in spontaneous writing. Furthermore, we demonstrate that pauses longer than 1.2 s may correspond to higher-level linguistic processing beyond a single propositional expression (functional element of the discourse.

  12. Sex differences in the refractory period of the 100 ms auditory evoked magnetic field.

    Science.gov (United States)

    Rojas, D C; Teale, P; Sheeder, J; Reite, M

    1999-11-08

    The 100 ms latency auditory evoked magnetic response (M100) has been implicated in the earliest stage of acoustic memory encoding in the brain. Sex differences in this response have been found in its location within the brain and its functional properties. We recorded the M100 in 25 adults in response to changes in interstimulus interval of an auditory stimulus. Response amplitudes of the M100 were used to compute a measure of the M100 refractory period, which has been proposed to index the decay time constant of echoic memory. This time constant was significantly longer in both hemispheres of the female participants when compared to the male participants. Possible implications of this for behavioral sex differences in human memory performance are discussed.

  13. Thermal Expansion Anomaly and Spontaneous Magnetostriction of Y2Fe14Al3 Compound

    International Nuclear Information System (INIS)

    Yan-Ming, Hao; Xin-Yuan, Jiang; Chun-Jing, Gao; Yan-Zhao, Wu; Yan-Yan, Zhang

    2009-01-01

    The structure and magnetic properties of Y 2 Fe 14 Al 3 compound are investigated by means of x-ray diffraction and magnetization measurements. The Y 2 Fe 14 Al 3 compound has a hexagonal Th 2 Ni 17 -type structure. Negative thermal expansion is found in Y 2 Fe 14 Al 3 compound in the temperature range from 403 to 491K by x-ray dilatometry. The coefficient of the average thermal expansion is α-bar = –2.54 × 10 −5 K −1 . The spontaneous magnetostrictive deformations from 283 to 470K are calculated by means of the differences between the experimental values of the lattice parameters and the corresponding values extrapolated from the paramagnetic range. The result shows that the spontaneous volume magnetostrictive deformation ω S decreases from 5.74 × 10 −3 to nearly zero with temperature increasing from 283 to 470 K, the spontaneous linear magnetostrictive deformation λ c along the c-axis is larger than the spontaneous linear magnetostrictive deformation λ a in basal-plane in the same temperature below 350 K

  14. Magnetic entropy change and critical exponents in double perovskite Y2NiMnO6

    Science.gov (United States)

    Sharma, G.; Tripathi, T. S.; Saha, J.; Patnaik, S.

    2014-11-01

    We report the magnetic entropy change (ΔSM) and the critical exponents in the double perovskite manganite Y2NiMnO6 with a ferromagnetic to paramagnetic transition TC~85 K. For a magnetic field change ΔH=80 kOe, a maximum magnetic entropy change ΔSM=-6.57 J/kg K is recorded around TC. The critical exponents β=0.363±0.05 and γ=1.331±0.09 obtained from power law fitting to spontaneous magnetization MS(T) and the inverse initial susceptibility χ0-1(T) satisfy well to values derived for a 3D-Heisenberg ferromagnet. The critical exponent δ=4.761±0.129 is determined from the isothermal magnetization at TC. The scaling exponents corresponding to second order phase transition are consistent with the exponents from Kouvel-Fisher analysis and satisfy Widom's scaling relation δ=1+(γ/β). Additionally, they also satisfy the single scaling equation M(H,ɛ)=ɛβf±(H/ɛ) according to which the magnetization-field-temperature data around TC should collapse into two curves for temperatures below and above TC.

  15. The Dresden 100 T/10 ms project a high magnetic field facility at an IR-FEL

    CERN Document Server

    Dorr, M; Eschrig, H; Fischer, F; Fulde, P; Groessinger, R; Grunberger, W; Handstein, A; Hinz, D; Kratz, R; Krug, H; Loewenhaupt, M; Müller, K H; Pobell, F; Schultz, L; Siegel, H; Steglich, F; Vergés, P

    2002-01-01

    Summary form only given. We have proposed to build a 100 T/10 ms, 70 T/100 ms, 60 T/1 s pulsed field user facility with a 50 MJ capacitor bank at the Forschungszentrum Rossendorf near Dresden. This would provide the appealing possibility to have access to Zeeman energies in the energy range of the infrared free-electron-lasers (5 mu m to 150 mu m; 2 ps; cw; >10 W) now under construction at the radiation source ELBE (superconducting electron linear accelerator; 40 MeV; 1 m A; 2 ps; cw) in Rossendorf. The work is accompanied by computer simulations of the planned coil systems, of the power supply, and by the development of high-strength conductors aiming at a tensile strength of about 1.5 GPa at sigma approximately= sigma /sub Cu//2 (microcomposite CuAg alloys and Cu-steel macro compounds). With a view of gaining experience in the construction and operation of pulsed magnets, a pilot pulsed field laboratory was established at the Institute of Solid State and Materials Research Dresden (IFW Dresden). The laborat...

  16. The neurophysiologist perspective into MS plasticity

    Directory of Open Access Journals (Sweden)

    Elise eHoudayer

    2015-09-01

    Full Text Available Multiple sclerosis (MS is a frequent, highly debilitating inflammatory demyelinating disease, starting to manifest in early adulthood and presenting a wide variety of symptoms which are often resistant to pharmacological treatments. Cortical dysfunctions have been demonstrated to be key components of MS condition, and plasticity of the corticospinal motor system is highly involved in major MS symptoms, such as fatigue, spasticity or pain. Cortical dysfunction in MS can be studied with neurophysiological tools such as electroencephalography (EEG and related techniques (evoked potentials – EPs or transcranial magnetic stimulation (TMS. These techniques are now widely used to provide essential elements of MS diagnosis and can also be used to modulate plasticity. Indeed the recent development of non-invasive brain stimulation (NIBS techniques able to induce cortical plasticity, such as repetitive TMS or transcranial direct current stimulation (tDCS, has brought promising results as add-on treatments.In this review we will focus on the use of these tools (EEG, TMS to study plasticity in MS and on the major techniques used to modulate plasticity in MS.

  17. The Neurophysiologist Perspective into MS Plasticity.

    Science.gov (United States)

    Houdayer, Elise; Comi, Giancarlo; Leocani, Letizia

    2015-01-01

    Multiple sclerosis (MS) is a frequent, highly debilitating inflammatory demyelinating disease, starting to manifest in early adulthood and presenting a wide variety of symptoms, which are often resistant to pharmacological treatments. Cortical dysfunctions have been demonstrated to be key components of MS condition, and plasticity of the corticospinal motor system is highly involved in major MS symptoms, such as fatigue, spasticity, or pain. Cortical dysfunction in MS can be studied with neurophysiological tools, such as electroencephalography (EEG) and related techniques (evoked potentials) or transcranial magnetic stimulation (TMS). These techniques are now widely used to provide essential elements of MS diagnosis and can also be used to modulate plasticity. Indeed, the recent development of non-invasive brain stimulation techniques able to induce cortical plasticity, such as repetitive TMS or transcranial direct current stimulation, has brought promising results as add-on treatments. In this review, we will focus on the use of these tools (EEG and TMS) to study plasticity in MS and on the major techniques used to modulate plasticity in MS.

  18. Polydopamine-Coated Magnetic Molecularly Imprinted Polymers with Fragment Template for Identification of Pulsatilla Saponin Metabolites in Rat Feces with UPLC-Q-TOF-MS.

    Science.gov (United States)

    Zhang, Yu-Zhen; Zhang, Jia-Wei; Wang, Chong-Zhi; Zhou, Lian-Di; Zhang, Qi-Hui; Yuan, Chun-Su

    2018-01-24

    In this work, a modified pretreatment method using magnetic molecularly imprinted polymers (MMIPs) was successfully applied to study the metabolites of an important botanical with ultraperformance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS). The MMIPs for glucoside-specific adsorption was used to identify metabolites of Pulsatilla chinensis in rat feces. Polymers were prepared by using Fe 3 O 4 nanoparticles as the supporting matrix, d-glucose as fragment template, and dopamine as the functional monomer and cross-linker. Results showed that MMIPs exhibited excellent extraction performance, large adsorption capacity (5.65 mg/g), fast kinetics (60 min), and magnetic separation. Furthermore, the MMIPs coupled with UPLC-Q-TOF-MS were successfully utilized for the identification of 17 compounds including 15 metabolites from the Pulsatilla saponin metabolic pool. This study provides a reliable protocol for the separation and identification of saponin metabolites in a complex biological sample, including those from herbal medicines.

  19. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control.

    Science.gov (United States)

    Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick

    2015-01-01

    This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Spontaneous emission spectra from a staggered-array undulator

    International Nuclear Information System (INIS)

    Shimada, Shigeki; Okada, Kouji; Masuda, Kai; Sobajima, Masaaki; Yoshikawa, Kiyoshi; Ohnishi, Masami; Yamamoto, Yasushi; Toku, Hisayuki

    1997-01-01

    A staggered-array undulator set inside the superconducting solenoid coils is shown to be able to provide high undulator fields larger than the longitudinal magnetic fields, a small undulator period, easy tunability through the solenoid coil current, and compact and easy fabrication. The overall performance characteristics of this undulator were studied mainly with respect to iron and aluminum disk widths, and spontaneous emission spectra through the numerical calculations. The maximum undulator field is found to be obtained for the ratio of the aluminum disk width to the undulator period of 0.45. The line widths (FWHM) of the spontaneous emission spectra, however, do not show N w -1 dependence on the number of the undulator period N w for practical beams with a Gaussian distribution, compared with for a single electron. The energy spread among various parameters is seen to play an important role in reducing the FWHM with increase of N w . The large tunability of the wavelength is proved to cover 6-10 mm by changing the solenoid magnetic field from 0.4 T to 1.6 T. (author)

  1. Spontaneous transition rates for electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2) and magnetic quadrupole (M2) transitions for He-like calcium and sulfur ions

    International Nuclear Information System (INIS)

    Kingston, A.E.; Norrington, P.H.; Boone, A.W.

    2002-01-01

    The spontaneous decay rates for the electric dipole (E1), electric quadrupole (E2), magnetic dipole (M1) and magnetic quadrupole (M2) transitions between all of the 1s 2 , 1s2 l and 1s3 l states have been obtained for helium-like calcium and sulfur ions. To assess the accuracy of the calculations, the transition probabilities were calculated using two sets of configuration interaction wavefunctions. One set of wavefunctions was generated using the fully relativistic GRASP code and the other was obtained using CIV3, in which relativistic effects are introduced using the Breit-Pauli approximation. The transition rates, A values, oscillator strengths and line strengths from our two calculations are found to be similar and to compare very well with other recent results for Δn=1 or 2 transitions. For Δn=0 transitions the agreement is much less good; this is mainly due to differences in the calculated excitation energies. (author)

  2. Spontaneous intracranial hypotension syndrome: magnetic resonance findings in two patients; Sindrome de hipotension intracraneal espontanea: hallazgos en resonancia magnetica en dos pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, R.; Pastor, J.; Escamilla, F.; Romero, M. I. [Hospital de Traumatologia y Reabilitacion. Granada (Spain)

    1999-07-01

    The postural headache syndrome associated with a decrease in the cerebrospinal fluid (CSF) pressure is generally secondary to the CSF leakage that usually occurs after diagnostic lumbar puncture. Spontaneous intracranial hypotension can not be attributed to any known cause or previous diagnostic or therapeutic intervention. The syndrome is characterized by severe headache that is relieved by lying supine. During lumbar puncture, the CSF pressure is normally low. We present two patients in whom gadolinium-enhanced magnetic resonance imaging showed widespread thickening and enhancement of the dura mater and subdural fluid collections. (Author) 13 refs.

  3. Towards a Decentralized Magnetic Indoor Positioning System

    Science.gov (United States)

    Kasmi, Zakaria; Norrdine, Abdelmoumen; Blankenbach, Jörg

    2015-01-01

    Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS), thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs) and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters. PMID:26690145

  4. Towards a Decentralized Magnetic Indoor Positioning System

    Directory of Open Access Journals (Sweden)

    Zakaria Kasmi

    2015-12-01

    Full Text Available Decentralized magnetic indoor localization is a sophisticated method for processing sampled magnetic data directly on a mobile station (MS, thereby decreasing or even avoiding the need for communication with the base station. In contrast to central-oriented positioning systems, which transmit raw data to a base station, decentralized indoor localization pushes application-level knowledge into the MS. A decentralized position solution has thus a strong feasibility to increase energy efficiency and to prolong the lifetime of the MS. In this article, we present a complete architecture and an implementation for a decentralized positioning system. Furthermore, we introduce a technique for the synchronization of the observed magnetic field on the MS with the artificially-generated magnetic field from the coils. Based on real-time clocks (RTCs and a preemptive operating system, this method allows a stand-alone control of the coils and a proper assignment of the measured magnetic fields on the MS. A stand-alone control and synchronization of the coils and the MS have an exceptional potential to implement a positioning system without the need for wired or wireless communication and enable a deployment of applications for rescue scenarios, like localization of miners or firefighters.

  5. A New In Vitro Co-Culture Model Using Magnetic Force-Based Nanotechnology.

    Science.gov (United States)

    Takanari, Hiroki; Miwa, Keiko; Fu, XianMing; Nakai, Junichi; Ito, Akira; Ino, Kousuke; Honda, Hiroyuki; Tonomura, Wataru; Konishi, Satoshi; Opthof, Tobias; van der Heyden, Marcel Ag; Kodama, Itsuo; Lee, Jong-Kook

    2016-10-01

    Skeletal myoblast (SkMB) transplantation has been conducted as a therapeutic strategy for severe heart failure. However, arrhythmogenicity following transplantation remains unsolved. We developed an in vitro model of myoblast transplantation with "patterned" or "randomly-mixed" co-culture of SkMBs and cardiomyocytes enabling subsequent electrophysiological, and arrhythmogenic evaluation. SkMBs were magnetically labeled with magnetite nanoparticles and co-cultured with neonatal rat ventricular myocytes (NRVMs) on multi-electrode arrays. SkMBs were patterned by a magnet beneath the arrays. Excitation synchronicity was evaluated by Ca(2+) imaging using a gene-encoded Ca(2+) indicator, G-CaMP2. In the monoculture of NRVMs (control), conduction was well-organized. In the randomly-mixed co-culture of NRVMs and SkMBs (random group), there was inhomogeneous conduction from multiple origins. In the "patterned" co-culture where an en bloc SKMB-layer was inserted into the NRVM-layer, excitation homogenously propagated although conduction was distorted by the SkMB-area. The 4-mm distance conduction time (CT) in the random group was significantly longer (197 ± 126 ms) than in control (17 ± 3 ms). In the patterned group, CT through NRVM-area did not change (25 ± 3 ms), although CT through the SkMB-area was significantly longer (132 ± 77 ms). The intervals between spontaneous excitation varied beat-to-beat in the random group, while regular beating was recorded in the control and patterned groups. Synchronized Ca(2+) transients of NRVMs were observed in the patterned group, whereas those in the random group were asynchronous. Patterned alignment of SkMBs is feasible with magnetic nanoparticles. Using the novel in vitro model mimicking cell transplantation, it may become possible to predict arrhythmogenicity due to heterogenous cell transplantation. J. Cell. Physiol. 231: 2249-2256, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  6. Combination of pentafluorophenylhydrazine derivatization and isotope dilution LC-MS/MS techniques for the quantification of apurinic/apyrimidinic sites in cellular DNA.

    Science.gov (United States)

    Li, Jie; Leung, Elvis M K; Choi, Martin M F; Chan, Wan

    2013-05-01

    Apurinic/apyrimidinic (AP) sites are common DNA lesions arising from spontaneous hydrolysis of the N-glycosidic bond and base-excision repair mechanisms of the modified bases. Due to the strong association of AP site formation with physically/chemically induced DNA damage, quantifying AP sites provides important information for risk assessment of exposure to genotoxins and oxidative stress. However, rigorous quantification of AP sites in DNA has been hampered by technical problems relating to the sensitivity and selectivity of existing analytical methods. We have developed a new isotope dilution liquid chromatography-coupled tandem mass spectrometry (LC-MS/MS) method for the rigorous quantification of AP sites in genomic DNA. The method entails enzymatic digestion of AP site-containing DNA by endo- and exonucleases, derivatization with pentafluorophenylhydrazine (PFPH), addition of an isotopically labeled PFPH derivative as internal standard, and quantification by LC-MS/MS. The combination of PFPH derivatization with LC-MS/MS analysis on a triple quadrupole mass spectrometer allows for sensitive and selective quantification of AP sites in DNA at a detection limit of 6.5 fmol, corresponding to 4 AP sites/10(9) nt in 5 μg of DNA, which is at least ten times more sensitive than existing analytical methods. The protocol was validated by AP site-containing oligonucleotides and applied in quantifying methyl methanesulfonate-induced formation of AP sites in cellular DNA.

  7. Effect of metallic and hyperbolic metamaterial surface on electric and magnetic dipole emission

    DEFF Research Database (Denmark)

    Ni, Xingjie; Naik, Gururaj V.; Kildishev, Alexander V.

    2010-01-01

    Spontaneous emission patterns of electric and magnetic dipoles on different material surfaces were studied numerically and experimentally. The results show the modified behavior of electric and magnetic dipoles on metallic and HMM surfaces.......Spontaneous emission patterns of electric and magnetic dipoles on different material surfaces were studied numerically and experimentally. The results show the modified behavior of electric and magnetic dipoles on metallic and HMM surfaces....

  8. Thermal and mechanical effects of quenches on Nb3Sn high field hadron collider magnets

    International Nuclear Information System (INIS)

    Ryuji, Yamada

    2001-01-01

    Thermal and its resulting mechanical stress due to quenches inside short and long epoxy impregnated Nb 3 Sn high field magnets are studied with a quench simulation program, Kuench, and ANSYS program. For the protection of a long high field magnet, we have to use heaters to dump the stored energy uniformly inside the magnet, after detection of a spontaneous quench. The time delay of starting a forced quench with heaters, is estimated using ANSYS. Using this information, the thermal distribution in two-dimensional magnet cross section is studied. First a one meter model magnet with a dump resistor is used to estimate the effects and then a 10 meter long magnet is studied. The two-dimensional temperature distributions in the magnet cross sections are recorded every 5 ms, and visually displayed. With this visual animation displays we can understand intuitively the thermal and quench propagation in 2-dimensional field. The quenching cables get heated locally much more than the surrounding material and non-quenching conductor cables. With a one meter magnet with a dump resistor of 30 mOmega, typically only the quench starting cables and its neighbor cables get heated up to 100 K without significant effects from the heaters. With a10 meter magnet, heaters cause the quenches to most of the conductor blocks. The quench initiating cables get up to 250 to 300 K in 100 ms, but the surrounding and wedges are not heated up significantly. This causes the excessive stress in the quenching conductors and in their insulation material locally. The stress and strain in the conductor as well as in the insulation become excessive, and they are studied using the ANSYS stress analysis, using Von Mises criterion. It is concluded that for the one meter magnet with the presented cross section and configuration, the thermal effects due to the quench is tolerable. But we need much more quench study and improvements in the design for the extended ten meter long magnet [1

  9. Magnetically induced vacuum decay

    International Nuclear Information System (INIS)

    Xue Shesheng

    2003-01-01

    We study the fermionic vacuum energy of vacua with and without application of an external magnetic field. The energetic difference of two vacua leads to the vacuum decaying and the vacuum energy being released. In the context of quantum field theories, we discuss why and how the vacuum energy can be released by spontaneous photon emission and/or paramagnetically screening the external magnetic field. In addition, we quantitatively compute the vacuum energy released, the paramagnetic screening effect, and the rate and spectrum of spontaneous photon emission. The possibilities of experimentally detecting such an effect of vacuum-energy release and that this effect accounts for the anomalous x-ray pulsar are discussed

  10. Synchrotron Diffraction Studies of Spontaneous Magnetostriction in Rare Earth Transition Metal Compounds

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ning [Iowa State Univ., Ames, IA (United States)

    2004-12-19

    Thermal expansion anomalies of R2Fe14B and R2Fe17Cx (x = 0,2) (R = Y, Nd, Gd, Tb, Er) stoichiometric compounds are studied with high-energy synchrotron X-ray powder diffraction using Debye-Schemer geometry in temperature range 10K to 1000K. Large spontaneous magnetostriction up to their Curie temperatures (Tc) is observed. The a-axes show relatively larger invar effects than c-axes in the R2Fe14B compounds whereas the R2Fe17Cx show the contrary anisotropies. The iron sub-lattice is shown to dominate the spontaneous magnetostriction of the compounds. The contribution of the rare earth sublattice is roughly proportional to the spin magnetic moment of the rare earth in the R2Fe14B compounds but in R2Fe17Cx, the rare earth sub-lattice contribution appears more likely to be dominated by the local bonding. The calculation of spontaneous magnetostrain of bonds shows that the bonds associated with Fe(j2) sites in R2Fe14B and the dumbbell sites in R2Fe17Cx have larger values, which is strongly related to their largest magnetic moment and Wigner-Seitz atomic cell volume. The roles of the carbon atoms in increasing the Curie temperatures of the R2Fe17 compounds are attributed to the increased separation of Fe hexagons. The R2Fe17 and R2Fe14B phases with magnetic rare earth ions also show anisotropies of thermal expansion above c. For R2Fe17 and R2Fe14B the a a/a c > 1 whereas the anisotropy is reversed with the interstitial carbon in R2Fe17. The average bond magnetostrain is shown to be a possible predictor of the magnetic moment of Fe sites in the compounds. Both of the theoretical and

  11. Magnetic anisotropy and magnetic phase transitions in RFe.sub.5./sub.Al.sub.7./sub..

    Czech Academy of Sciences Publication Activity Database

    Gorbunov, Denis; Yasin, S.; Andreev, Alexander V.; Skourski, Y.; Mushnikov, N. V.; Rosenfeld, E.V.; Zherlitsyn, S.; Wosnitza, J.

    2015-01-01

    Roč. 383, Jun (2015), 208-214 ISSN 0304-8853 R&D Projects: GA ČR GAP204/12/0150 Grant - others:AVČR(CZ) M100101203 Institutional support: RVO:68378271 Keywords : rare-earth intermetallics * magnetic anisotropy * ferrimagnetism * high magnetic fields * spontaneous transition * field-induced transition Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.357, year: 2015

  12. Self energy QED: Multipole spontaneous emission

    International Nuclear Information System (INIS)

    Salamin, Y.I.

    1990-08-01

    Within the context of Barut's self-field approach, we write the exact expression of the spontaneous atomic decay rate (Phys. Rev. A37, 2284 (1988)), in the long wavelength approximation, in terms of electric- and magnetic-like multipole contributions which are related to the matrix elements of the transition charge and current distributions of the relativistic electron. A number of features of these expressions are discussed and their generalization to interacting composite systems is also pointed out. (author). 8 refs

  13. Spontaneous rupture of intracranial dermoid tumor in a patient with vertigo. Computed tomography and magnetic resonance imaging findings

    International Nuclear Information System (INIS)

    Asil, Kıyasettin; Gunduz, Yasemin; Ayhan, Laçin Tatli; Aksoy, Yakup Ersel; Yildiz, Can

    2013-01-01

    Congenital dermoid cysts are very rare, constituting less than 1% of intracranial tumors. Spontaneous rupture of dermoid tumor is a potentially serious complication that can lead to meningitis, seizures, cerebral ischemia and hydrocephalus. Occasionally, dermoid tumors are incidentally discovered on computed tomography (CT) of the brain or magnetic resonance imaging (MRI) following unrelated clinical complaints. They are also discovered during radiologic investigations of unexplained headaches, seizures, and rarely olfactory delusions. In this report we describe a patient complaining of vertigo caused by spontaneous rupture of dermoid cyst, preoperatively diagnosed by CT and MRI. Cranial CT revealed a dense fatty lesion adjacent to the posterolateral parasellar region on the left with multiple small, dense fat droplets scattered in the subarachnoid space corresponding to a dermoid cyst rupture. Cranial MRI sections revealed a lesion with mixed-signal-intensity and multiple hyperintense droplets scattered through the cerebellar surface on the left. No enhancement was found on axial T1-weighted MRI after intravenous Gadolinium administration. Diffusion weighted image (DWI) and apparent diffusion coefficient map studies exhibited explicit restricted diffusion. Many studies and literature case reports concerning the rupture of dermoid cyst have been reported. However, multimodal imaging of this rare pathology in the same patient is uncommon. Although dermoid cysts are pathognomonic in appearance on a CT examination, the MRI is also of value in helping to understand the effect of extension and pressure of the mass. DWI is also important for support of the diagnosis and patient follow-up

  14. Spontaneous bending of pre-stretched bilayers.

    Science.gov (United States)

    DeSimone, Antonio

    2018-01-01

    We discuss spontaneously bent configurations of pre-stretched bilayer sheets that can be obtained by tuning the pre-stretches in the two layers. The two-dimensional nonlinear plate model we use for this purpose is an adaptation of the one recently obtained for thin sheets of nematic elastomers, by means of a rigorous dimensional reduction argument based on the theory of Gamma-convergence (Agostiniani and DeSimone in Meccanica. doi:10.1007/s11012-017-0630-4, 2017, Math Mech Solids. doi:10.1177/1081286517699991, arXiv:1509.07003, 2017). We argue that pre-stretched bilayer sheets provide us with an interesting model system to study shape programming and morphing of surfaces in other, more complex systems, where spontaneous deformations are induced by swelling due to the absorption of a liquid, phase transformations, thermal or electro-magnetic stimuli. These include bio-mimetic structures inspired by biological systems from both the plant and the animal kingdoms.

  15. Effect of hydrostatic pressure on magnetic phase transitions and magnetization in gadolinium monocrystal

    International Nuclear Information System (INIS)

    Nikitin, S.A.; Bezdushnyj, R.V.

    1989-01-01

    Effect of hydrostatic pressure on magnetization in gadolinium monocrystal (Δσ-effect) was investigated. Dependences of spesific magnetization, Δσ-effect and bulk magnetostriction of gadolinium monocrystal on temperatures were studied. Results of conducted investigation have shown that in gadolinium the change of specific magnetization under the hydrostatic pressure effect is caused in general case by three effects: a)change of spontaneous magnetization under the effect of hydrostatic pressure; b)change of magnetization within technical magnetization range due to the effect of hydrostatic pressure on magnetic anisotropy constants; c)change of magnetization due to the effect of hydrostatic pressure on temperature of spin-reoriented transition

  16. Optimization of permanent-magnet undulator magnets ordering using simulated annealing algorithm

    International Nuclear Information System (INIS)

    Chen Nian; He Duohui; Li Ge; Jia Qika; Zhang Pengfei; Xu Hongliang; Cai Genwang

    2005-01-01

    Pure permanent-magnet undulator consists of many magnets. The unavoidable remanence divergence of these magnets causes the undulator magnetic field error, which will affect the functional mode of the storage ring and the quality of the spontaneous emission spectrum. Optimizing permanent-magnet undulator magnets ordering using simulated annealing algorithm before installing undulator magnets, the first field integral can be reduced to 10 -6 T·m, the second integral to 10 -6 T·m 2 and the peak field error to less than 10 -4 . The optimized results are independent of the initial solution. This paper gives the optimizing process in detail and puts forward a method to quickly calculate the peak field error and field integral according to the magnet remanence. (authors)

  17. Spontaneous intracranial arterial dissection in the young: diagnosis by CT angiography

    Directory of Open Access Journals (Sweden)

    Given Curtis A

    2006-04-01

    Full Text Available Abstract Background Spontaneous carotid artery dissections have been rarely reported in children. Diagnosis has traditionally been confirmed by catheter arteriography. More recently diagnosis has been made by magnetic resonance imaging and magnetic resonance angiography; however the sensitivity of these techniques has yet to be determined. The authors are unaware of reports of carotid dissection confirmed by dynamic computed tomography (computerized tomographic arteriography in the young. Case presentation We recently evaluated a fourteen year-old male following the development of transient neurologic symptoms. There was no antecedent illness or trauma. Dynamic computed tomography revealed an intracranial dissection involving the supraclinoid segment of the left internal carotid artery (confirmed by catheter arteriography. Studies for vasculitis, pro-thrombotic states, and defects of collagen were negative. Conclusion Spontaneous carotid artery dissection is a potential cause of transient neurological symptoms and ischemic stroke in the pediatric population. Dynamic computed tomography appears to be a reliable diagnostic tool which can lead to early diagnosis.

  18. Spontaneous mutation by mutagenic repair of spontaneous lesions in DNA

    International Nuclear Information System (INIS)

    Hastings, P.J.; Quah, S.-K.; Borstel, R.C. von

    1976-01-01

    It is stated that strains of yeast carrying mutations in many of the steps in pathways repairing radiation-induced damage to DNA have enhanced spontaneous mutation rates. Most strains isolated because they have enhanced spontaneous mutation carry mutations in DNA repair systems. This suggests that much spontaneous mutation arises by mutagenic repair of spontaneous lesions. (author)

  19. Voltage control of a magnetization easy axis in piezoelectric/ferromagnetic hybrid films

    International Nuclear Information System (INIS)

    Kim, Sang-Koog; Lee, Jeong-Won; Shin, Sung-Chul; Song, Han Wook; Lee, Chang Ho; No, Kwangsoo

    2003-01-01

    We have established a spontaneous magnetization-axis switching in ferromagnetic films by applying a low voltage to a piezoelectric layer in a newly developed hybrid system comprised of the ferromagnetic and piezoelectric films. The magnetization easy axis along which a spontaneous magnetization is oriented, is readily switchable by a voltage without applying an external magnetic field through both the inverse magnetostrictive and piezoelectric effects of CoPd and lead-zirconate-titanate alloy films, respectively. This challenging work provides a new way into the memory writing as well as storage means of ultrahigh bit densities in nonvolatile magnetic random access memory

  20. Composite Microdiscs with a Magnetic Belt

    DEFF Research Database (Denmark)

    Knaapila, Matti; Høyer, Henrik; Helgesen, Geir

    2015-01-01

    , the spontaneous aggregation of composite particles is suppressed when dispersed into liquid, which is attributed to the increased particle size, reduced magnetic susceptibility, and the shape of the magnetic domain distribution within the particles (spherical versus a belt). When the composite particles...

  1. Spontaneous magnetoelastic effects in gadolinium compounds

    International Nuclear Information System (INIS)

    Lindbaum, A.; Rotter, M.

    2002-01-01

    Full text: This poster is a short summary of a recently published handbook chapter, where the spontaneous magnetoelastic effects in Gd compounds are reviewed showing that the strain dependence of the magnetic exchange interactions leads to significant effects. These effects are equal in magnitude to well established single ion contributions in other rare earth compounds with non vanishing orbital momentum (coming from the strain dependence of the crystal field). In some cases the exchange contribution can produce giant magnetostriction (GMS) or induce structural phase transitions. In order to extract the influence of the Gd- Gd exchange interactions, we consider only Gd compounds with partner elements showing no or only weak induced magnetic moments. The current status of the theory is presented and compared to measurements performed by temperature dependent x-ray diffraction and results of dilatometric measurements. (author)

  2. Normal values of quantitative T2′ in a spontaneously hypertensive stroke prone rat stem at 3 T

    International Nuclear Information System (INIS)

    Jensen-Kondering, U.; Böhm, R.; Höcker, J.; Ruhe, R.; Brdon, J.; Ulmer, S.; Herdegen, T.; Jansen, O.

    2012-01-01

    Introduction: Regarding therapy and prognosis of acute ischemic stroke the identification of ischemic penumbra is pivotal. A promising candidate is BOLD-imaging using qT2′-maps. For valid interpretation of experimental studies in animals normal values for qT2′ are needed. Normal values in humans at 1.5 T already exist. Normal values for cortical and subcortical structures in a spontaneously hypertensive stroke prone rat stem (SHR-SP) at a fieldstrength of 3 T are reported. Materials and methods: 39 (20 males and 19 females) spontaneously hypertensive stroke prone (SHRSP) rats were examined in a 3 T scanner using a dedicated small animal coil. Mean weight was 144.1 ± 8.2 g and mean age was 60.2 ± 2.7 days. For the calculation of qT2′ multiple echo T2w and T2*w images were acquired. ROIs were placed into deep and cortical grey matter in five different brain regions to obtain values for qT2′, qT2 and qT2*. Results: Mean qT2′ for cortical grey matter was 74.76 ± 33.27 ms and 67.73 ± 17.86 ms for deep grey matter. The 99% confidence interval for cortical grey matter was 69.91–79.61 ms. For qT2 it was 79.02 ± 2.9 ms and 70.45 ± 1.89 ms, respectively. For qT2* it was 34.65 ± 5.25 ms and 31.9 ± 2.99 ms. Conclusion: The values for qT2′ presented here can serve as reference values for further studies examining the ischemic penumbra in a rat model.

  3. Effects of anomalous magnetic moment and temperature on pair production in an external magnetic field

    International Nuclear Information System (INIS)

    Dittrich, W.; Bauhoff, W.

    1981-01-01

    It is re-examined the problem of spontaneous pair creation in an external magnetic field. In contrast to earlier findings, it is shown that pair production does not occur due to the anomalous magnetic moment interaction. However, pairs may be observed in a situation of thermodynamic equilibrium at finite temperatures. (author)

  4. Stock market speculation: Spontaneous symmetry breaking of economic valuation

    Science.gov (United States)

    Sornette, Didier

    2000-09-01

    Firm foundation theory estimates a security's firm fundamental value based on four determinants: expected growth rate, expected dividend payout, the market interest rate and the degree of risk. In contrast, other views of decision-making in the stock market, using alternatives such as human psychology and behavior, bounded rationality, agent-based modeling and evolutionary game theory, expound that speculative and crowd behavior of investors may play a major role in shaping market prices. Here, we propose that the two views refer to two classes of companies connected through a "phase transition". Our theory is based on (1) the identification of the fundamental parity symmetry of prices (p→-p), which results from the relative direction of payment flux compared to commodity flux and (2) the observation that a company's risk-adjusted growth rate discounted by the market interest rate behaves as a control parameter for the observable price. We find a critical value of this control parameter at which a spontaneous symmetry-breaking of prices occurs, leading to a spontaneous valuation in absence of earnings, similarly to the emergence of a spontaneous magnetization in Ising models in absence of a magnetic field. The low growth rate phase is described by the firm foundation theory while the large growth rate phase is the regime of speculation and crowd behavior. In practice, while large "finite-time horizon" effects round off the predicted singularities, our symmetry-breaking speculation theory accounts for the apparent over-pricing and the high volatility of fast growing companies on the stock markets.

  5. Anomalous magnetic aftereffect and thermal remagnetization in melt-spun Nd4 Fe77 B19 permanent magnets

    International Nuclear Information System (INIS)

    Mueller, K.H.; Eckert, D.; Handstein, A.; Wolf, M.; Collocott, S.; Andrikidis, C.

    1996-01-01

    Usually measurements of the magnetic after effect in permanent magnet materials are performed on the major demagnetization curve. In this investigation, however, we measured the time dependence of magnetization of the spring magnet Nd 4 Fe 77 B 19 for different magnetic pre histories. The measurements were done with SQUID magnetometers. Depending on the magnetic pre history the magnetic viscosity S can be positive as well as negative, even for the same 'coordinate' (J,H), i.e. the system does not always move directly towards the thermal equilibrium state. In particular the samples spontaneously remagnetize after being field demagnetized. The driving force for this effect may be similar as that for thermal remagnetization. For certain magnetic pre histories the magnetization J (t) depends non-monotonically on time t, i.e. it can not always be described by a formula S 1 n(1 + t/t o ). Similar effects observed for αFe, many years ago, have been called anomalous aftereffect. These observations were attributed to the reversible aftereffect associated with the diffusion of C-atoms in α-Fe. However, the reversible aftereffect is not typical for permanent magnet materials. THe anomalous aftereffect found in our investigation as well as the effects of spontaneous remagnetization will be explained in terms of magnetic interactions in the material. (author)

  6. Confirmation of T1-Bright Vein of Galen Aneurysm Spontaneous Thrombosis by Subtraction Magnetic Resonance Venography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Irfan, M.; Lohman, B.; McKinney, A.M. (Dept. of Radiology/Neuroradiology, Univ. of Minnesota, Minneapolis, Minnesota (United States))

    2009-08-15

    Spontaneous thrombosis of a vein of Galen aneurysmal malformation (VOGM) is rare. We describe a 2-month-old patient with a patent VOGM and hydrocephalus, also confirmed patent at 6 months, but with subsequent lack of filling on pre-embolization catheter digital subtraction angiography (DSA) at 9 months' age. Due to the presence of T1- and T2-bright signal, noncontrast T1-weighted images (T1WI), T2-weighted images (T2WI), two-dimensional (2D) time-of-flight (TOF) magnetic resonance venography (MRV), and postcontrast T1WI were ambiguous for patency. However, subtracting the pre- from the postcontrast MRV images confirmed closure compared to subtracted images at 6 months' age. The factors contributing to thrombosis were likely a combination of a disproportionately small straight sinus, ventriculostomy, and contrast medium from DSA.

  7. Transport properties of graphene under periodic and quasiperiodic magnetic superlattices

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Wei-Tao, E-mail: luweitao@lyu.edu.cn [School of Science, Linyi University, 276005 Linyi (China); Institute of Condensed Matter Physics, Linyi University, 276005 Linyi (China); Wang, Shun-Jin [Department of Physics, Sichuan University, 610064 Chengdu (China); Wang, Yong-Long; Jiang, Hua [School of Science, Linyi University, 276005 Linyi (China); Institute of Condensed Matter Physics, Linyi University, 276005 Linyi (China); Li, Wen [School of Science, Linyi University, 276005 Linyi (China)

    2013-08-15

    We study the transmission of Dirac electrons through the one-dimensional periodic, Fibonacci, and Thue–Morse magnetic superlattices (MS), which can be realized by two different magnetic blocks arranged in certain sequences in graphene. The numerical results show that the transmission as a function of incident energy presents regular resonance splitting effect in periodic MS due to the split energy spectrum. For the quasiperiodic MS with more layers, they exhibit rich transmission patterns. In particular, the transmission in Fibonacci MS presents scaling property and fragmented behavior with self-similarity, while the transmission in Thue–Morse MS presents more perfect resonant peaks which are related to the completely transparent states. Furthermore, these interesting properties are robust against the profile of MS, but dependent on the magnetic structure parameters and the transverse wave vector.

  8. Interpretation of specific-heat and spontaneous-magnetization anomalies at the reentrant superconducting - ferromagnetic transition in (Ho0.6Er0.4)Rh4B4

    International Nuclear Information System (INIS)

    Woolf, L.D.; Johnston, D.C.; Mook, H.A.; Koehler, W.C.; Maple, M.B.; Fisk, Z.

    1981-09-01

    Analysis of neutron-diffraction data on the compound (Ho 0 . 6 Er 0 . 4 )Rh 4 B 4 indicates that the Curie temperature is depressed by about 0.2 K due to the occurrence of superconductivity, in agreement with theoretical predictions. The temperature dependence of the specific heat in the vicinity of the first-order reentrant superconducting - ferromagnetic transition was computed by means of a simple model from the temperature dependence of the spontaneous magnetization of the Ho ions and was found to be in good agreement with the experimental data

  9. Spontaneous pneumorrhachis and transverse myelitis complicating purulent meningitis

    Directory of Open Access Journals (Sweden)

    Bouchra Amara

    2013-01-01

    Full Text Available Pneumorrhachis is the presence of air in the spinal canal; mostly, it has an iatrogenic origin. The association of this entity with spontaneous pneumomediastinum without any pneumothorax is rarely reported in the literature. The spontaneous resorption is the usual evolution. The association to acute transverse myelitis is discussed by the authors. The patient is a 21-year-old male with pneumorrhachis associated to a spontaneous pneumomediastinum was admitted at the emergency department for bacterial meningitis. The antibiotherapy has marked the clinical profile by disappearance of the meningeal signs in the 48 h after admission. In contrast, the neurological symptoms were of marked aggravation by appearance of a tetraparesis with a respiratory distress syndrome having required artificial ventilation. The computed tomography (CT scan showed a typical hypodensity corresponding to paramedullary air extending to several thoracic segments. The spinal magnetic resonance imaging (MRI showed a high cervical medullary edema without signs of compression. The patient died within 15 days with a profile of vasoparalysis resistant to vasoactive drugs. Pneumomediastinum associated to pneumorrhachis and transverse myelitis complicating purulent meningitis is a rare entity. Although the usual evolution is favorable, the occurrence of serious complications is possible.

  10. Magnetic properties of the Ce2Fe17-x Mn x helical magnets up to high magnetic fields

    International Nuclear Information System (INIS)

    Kuchin, A.G.; Mushnikov, N.V.; Bartashevich, M.I.; Prokhnenko, O.; Khrabrov, V.I.; Lapina, T.P.

    2007-01-01

    Magnetic properties of the Ce 2 Fe 17- x Mn x , x=0-2, alloys in magnetic fields up to 40 T are reported. The compounds with x=0.5-1 are helical antiferromagnets and those with 1 B that couple antiparallelly to the Fe moments. Easy-plane magnetic anisotropy in the Ce 2 Fe 17- x Mn x compounds weakens upon substitution of Mn for Fe. The absolute value of the first anisotropy constant in the Ce 2 Fe 17- x Mn x helical ferromagnets decreases slower with increasing temperature than that calculated from the third power of the spontaneous magnetization. Noticeable magnetic hysteresis in the Ce 2 Fe 17- x Mn x , x=0.5-2, helical magnets over the whole range of magnetic fields reflects mainly irreversible deformation of the helical magnetic structure during the magnetization of the compounds. A contribution from short-range order (SRO) magnetic clusters to the magnetic hysteresis of the helical magnets has been also estimated

  11. Comparison of Magnetization Tunneling in the Giant-Spin and Multi-Spin Descriptions of Single-Molecule Magnets

    Science.gov (United States)

    Liu, Junjie; Del Barco, Enrique; Hill, Stephen

    2010-03-01

    We perform a mapping of the spectrum obtained for a triangular Mn3 single-molecule magnet (SMM) with idealized C3 symmetry via exact diagonalization of a multi-spin (MS) Hamiltonian onto that of a giant-spin (GS) model which assumes strong ferromagnetic coupling and a spin S = 6 ground state. Magnetic hysteresis measurements on this Mn3 SMM reveal clear evidence that the steps in magnetization due to magnetization tunneling obey the expected quantum mechanical selection rules [J. Henderson et al., Phys. Rev. Lett. 103, 017202 (2009)]. High-frequency EPR and magnetization data are first fit to the MS model. The tunnel splittings obtained via the two models are then compared in order to find a relationship between the sixth order transverse anisotropy term B6^6 in GS model and the exchange constant J coupling the Mn^III ions in the MS model. We also find that the fourth order transverse term B4^3 in the GS model is related to the orientation of JahnTeller axes of Mn^III ions, as well as J

  12. Reduced NAA-levels in the NAWM of patients with MS is a feature of progression. A study with quantitative magnetic resonance spectroscopy at 3 Tesla.

    Science.gov (United States)

    Aboul-Enein, Fahmy; Krssák, Martin; Höftberger, Romana; Prayer, Daniela; Kristoferitsch, Wolfgang

    2010-07-20

    Reduced N-acetyl-aspartate (NAA) levels in magnetic resonance spectroscopy (MRS) may visualize axonal damage even in the normal appearing white matter (NAWM). Demyelination and axonal degeneration are a hallmark in multiple sclerosis (MS). To define the extent of axonal degeneration in the NAWM in the remote from focal lesions in patients with relapsing-remitting (RRMS) and secondary progressive MS (SPMS). 37 patients with clinical definite MS (27 with RRMS, 10 with SPMS) and 8 controls were included. We used 2D (1)H-MR-chemical shift imaging (TR = 1500ms, TE = 135ms, nominal resolution 1ccm) operating at 3Tesla to assess the metabolic pattern in the fronto-parietal NAWM. Ratios of NAA to creatine (Cr) and choline (Cho) and absolute concentrations of the metabolites in the NAWM were measured in each voxel matching exclusively white matter on the anatomical T2 weighted MR images. No significant difference of absolute concentrations for NAA, Cr and Cho or metabolite ratios were found between RRMS and controls. In SPMS, the NAA/Cr ratio and absolute concentrations for NAA and Cr were significantly reduced compared to RRMS and to controls. In our study SPMS patients, but not RRMS patients were characterized by low NAA levels. Reduced NAA-levels in the NAWM of patients with MS is a feature of progression.

  13. Observation of Various and Spontaneous Magnetic Skyrmionic Bubbles at Room Temperature in a Frustrated Kagome Magnet with Uniaxial Magnetic Anisotropy

    KAUST Repository

    Hou, Zhipeng

    2017-06-07

    The quest for materials hosting topologically protected skyrmionic spin textures continues to be fueled by the promise of novel devices. Although many materials have demonstrated the existence of such spin textures, major challenges remain to be addressed before devices based on magnetic skyrmions can be realized. For example, being able to create and manipulate skyrmionic spin textures at room temperature is of great importance for further technological applications because they can adapt to various external stimuli acting as information carriers in spintronic devices. Here, the first observation of skyrmionic magnetic bubbles with variable topological spin textures formed at room temperature in a frustrated kagome Fe3 Sn2 magnet with uniaxial magnetic anisotropy is reported. The magnetization dynamics are investigated using in situ Lorentz transmission electron microscopy, revealing that the transformation between different magnetic bubbles and domains is via the motion of Bloch lines driven by an applied external magnetic field. These results demonstrate that Fe3 Sn2 facilitates a unique magnetic control of topological spin textures at room temperature, making it a promising candidate for further skyrmion-based spintronic devices.

  14. Spontaneous osteonecrosis of the knee associated with tibial plateau and femoral condyle insufficiency stress fracture

    Energy Technology Data Exchange (ETDEWEB)

    Narvaez, J.A.; Narvaez, J.; Lama, E.De; Sanchez, A. [Department of Magnetic Resonance Imaging, IDI Hospital Duran i Reynals, Ciutat Sanitaria i Universitaria de Bellvitge, Gran Via s/n, 08907, L' Hospitalet de Llobregat (Barcelona) (Spain)

    2003-08-01

    The purpose of this article is to describe the association between spontaneous osteonecrosis and insufficiency stress fractures of the knee. To determine whether insufficiency stress fracture is associated with spontaneous osteonecrosis of the knee, we retrospectively reviewed the medical charts and imaging studies of all patients with spontaneous osteonecrosis of the knee, studied by MR imaging, seen in a tertiary hospital over an 8-year period. Four women (age range 66-84 years) presented spontaneous osteonecrosis of the knee associated with insufficiency stress fracture of the medial tibial plateau. One of these patients also presented a concomitant insufficiency stress fracture of the medial femoral condyle. Radiographs were diagnostic of spontaneous osteonecrosis of the medial femoral condyle in three cases, and insufficiency stress fracture of the medial tibial plateau was detected in one case. Magnetic resonance imaging allows the diagnosis of both conditions in all four cases. Spontaneous osteonecrosis of the knee may be associated with insufficiency stress fracture of the medial femoral condyle and the medial tibial plateau. This association provides additional arguments in favor of the traumatic etiology of spontaneous osteonecrosis of knee. (orig.)

  15. Spontaneous osteonecrosis of the knee associated with tibial plateau and femoral condyle insufficiency stress fracture

    International Nuclear Information System (INIS)

    Narvaez, J.A.; Narvaez, J.; Lama, E.De; Sanchez, A.

    2003-01-01

    The purpose of this article is to describe the association between spontaneous osteonecrosis and insufficiency stress fractures of the knee. To determine whether insufficiency stress fracture is associated with spontaneous osteonecrosis of the knee, we retrospectively reviewed the medical charts and imaging studies of all patients with spontaneous osteonecrosis of the knee, studied by MR imaging, seen in a tertiary hospital over an 8-year period. Four women (age range 66-84 years) presented spontaneous osteonecrosis of the knee associated with insufficiency stress fracture of the medial tibial plateau. One of these patients also presented a concomitant insufficiency stress fracture of the medial femoral condyle. Radiographs were diagnostic of spontaneous osteonecrosis of the medial femoral condyle in three cases, and insufficiency stress fracture of the medial tibial plateau was detected in one case. Magnetic resonance imaging allows the diagnosis of both conditions in all four cases. Spontaneous osteonecrosis of the knee may be associated with insufficiency stress fracture of the medial femoral condyle and the medial tibial plateau. This association provides additional arguments in favor of the traumatic etiology of spontaneous osteonecrosis of knee. (orig.)

  16. Magnon heat capacity and magnetic susceptibility of the spin Lieb lattice

    Energy Technology Data Exchange (ETDEWEB)

    Yarmohammadi, Mohsen, E-mail: m.yarmohammadi69@gamil.com

    2016-11-01

    Using linear response theory, Heisenberg model Hamiltonian and Green's function technique, the influences of Dzyaloshinskii–Moriya interaction (DMI), external magnetic field and next-nearest-neighbor (NNN) coupling on the density of magnon modes (DMM), the magnetic susceptibility (MS) and the magnon heat capacity (MHC) of a spin Lieb lattice, a face-centered square lattice, are investigated. The results reveal a band gap in the DMM and we witness an extension in the bandwidth and an increase in the number of van-Hove singularities as well. As a notable point, besides the magnetic nature which includes ferromagnetism in spin Lieb-based nanosystems, MS is investigated. Further, we report a Schottky anomaly in the MHC. The results show that the effects of the magnetic field on the MHC and MS have different behaviors in two temperature regions. In the low temperature region, MHC and MS increase when the magnetic field strength increases. On the other hand, the MHC and MS reduce with increasing the magnetic field strength in the high temperature region. Also comprehensive numerical modelling of the DMM, the MS and the MHC of a spin Lieb lattice yields excellent qualitative agreement with the experimental data. - Highlights: • Theoretical calculation of density of states of the spin Lieb lattice. • The investigation of the effect of external magnetic field on the magnon heat capacity and magnetic susceptibility. • The investigation of the effect of NNN coupling and the DMI strength on the magnon heat capacity and magnetic susceptibility.

  17. Magnetic resonance volumetry of the hippocampus in familial spontaneous epileptic cats.

    Science.gov (United States)

    Mizoguchi, Shunta; Hasegawa, Daisuke; Kuwabara, Takayuki; Hamamoto, Yuji; Ogawa, Fukie; Fujiwara, Aki; Matsuki, Naoaki; Fujita, Michio

    2014-12-01

    A strain of familial spontaneous epileptic cats (FSECs) with typical limbic seizures was identified in 2010. The electroencephalographic features suggested that an epileptogenic zone is present in the mesial temporal structures (i.e., amygdala and/or hippocampus). In this study, visual evaluations and quantitative analyses were performed by using 3D MR hippocampal volumetry in comparing FSECs with age-matched controls. Visual hippocampal asymmetries were seen in 8 of 14 (57.1%) FSECs. The FSEC group showed a significantly higher asymmetric ratio (4.15%) than the control group (0.99%). The smaller side of hippocampal volume (HV) (0.206 cm(3)) in FSECs was significantly smaller than the mean HV in controls (0.227 cm(3)). However, the means of left and right HVs and total HVs in FSECs showed no differences because the laterality of hippocampal atrophy was different in each individual. Therefore, since FSECs represent a true model of spontaneous epilepsy, hippocampal volumetry should be evaluated in each individual as well as in human patients. The significant asymmetry of HV suggests the potential for hippocampal atrophy in FSECs. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Magnetic graphene composites as both an adsorbent for sample enrichment and a MALDI-TOF MS matrix for the detection of nitropolycyclic aromatic hydrocarbons in PM2.5.

    Science.gov (United States)

    Zhang, Jiangang; Zhang, Li; Li, Ruijin; Hu, Di; Ma, Nengxuan; Shuang, Shaomin; Cai, Zongwei; Dong, Chuan

    2015-03-07

    A simple and rapid method that uses synthesized magnetic graphene composites as both an adsorbent for enrichment and as a matrix in MALDI-TOF MS analysis was developed for the detection of nitropolycyclic hydrocarbons (nitro-PAHs) in PM2.5 samples. Three nitro-PAHs were detected down to sub pg μL(-1) levels based on calculations from an instrumental signal-to-noise better than 3, which shows the feasibility of using the new materials in MALDI-TOF MS as a potential powerful analytical approach for the analysis of nitro-PAHs in PM2.5 samples.

  19. Calculations of the self-amplified spontaneous emission performance of a free-electron laser

    International Nuclear Information System (INIS)

    Dejus, R. J.

    1999-01-01

    The linear integral equation based computer code (RON: Roger Oleg Nikolai), which was recently developed at Argonne National Laboratory, was used to calculate the self-amplified spontaneous emission (SASE) performance of the free-electron laser (FEL) being built at Argonne. Signal growth calculations under different conditions are used for estimating tolerances of actual design parameters. The radiation characteristics are discussed, and calculations using an ideal undulator magnetic field and a real measured magnetic field will be compared and discussed

  20. Magnetic properties of magnetic liquids with iron-oxide particles - the influence of anisotropy and interactions

    DEFF Research Database (Denmark)

    Johansson, C.; Hanson, M.; Pedersen, Michael Stanley

    1997-01-01

    Magnetic liquids containing iron-oxide particles were investigated by magnetization and Mossbauer measurements. The particles were shown to be maghemite with a spontanious saturation magentization Ms = 320 kA m-1 at 200 K and a normalized high-field susceptibility x/M0 = 5.1x10-6 mkA-1, practically...... independent of temperature. Ms increases with decreasing temperature according to an effective Bloch law with an exponent larger than 1.5, as expected for fine magnetic particles. The model of magnetic particles with uniaxial anisotropy and the actual size distribution gives a consistent description...... of independent measurements of the temperature dependence of the hyperfine field and the isothermal magnetization versus field. From this an effective anisotropy constant of about 4.5x10 4 J m-3 is estimated for a particle with diameter 7.5 nm. The magnetic relaxation, as observed in zero...

  1. Magnetization of left-handed metamaterials

    International Nuclear Information System (INIS)

    Kourakis, I; Shukla, P K

    2006-01-01

    We propose a possible mechanism for the generation of magnetic fields in negative refraction index composite metamaterials. Considering the propagation of a high-frequency modulated amplitude electric field in a left-handed material (LHM), we show that the ponderomotive interaction between the field and low-frequency potential distributions leads to spontaneous generation of magnetic fields, whose form and properties are discussed

  2. Contribution of spontaneous polarization and its fluctuations to refraction of light in ferroelectrics

    Czech Academy of Sciences Publication Activity Database

    Markovin, P.A.; Trepakov, Vladimír; Tagantsev, A. K.; Dejneka, Alexandr; Andreev, D. A.

    2016-01-01

    Roč. 58, č. 1 (2016), 134-139 ISSN 1063-7834 R&D Projects: GA ČR GA15-13778S Institutional support: RVO:68378271 Keywords : contribution * spontaneous polarization * fluctuations * refraction * light * ferroelectrics Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.860, year: 2016

  3. Does Spontaneous Favorability to Power (vs. Universalism) Values Predict Spontaneous Prejudice and Discrimination?

    Science.gov (United States)

    Souchon, Nicolas; Maio, Gregory R; Hanel, Paul H P; Bardin, Brigitte

    2017-10-01

    We conducted five studies testing whether an implicit measure of favorability toward power over universalism values predicts spontaneous prejudice and discrimination. Studies 1 (N = 192) and 2 (N = 86) examined correlations between spontaneous favorability toward power (vs. universalism) values, achievement (vs. benevolence) values, and a spontaneous measure of prejudice toward ethnic minorities. Study 3 (N = 159) tested whether conditioning participants to associate power values with positive adjectives and universalism values with negative adjectives (or inversely) affects spontaneous prejudice. Study 4 (N = 95) tested whether decision bias toward female handball players could be predicted by spontaneous attitude toward power (vs. universalism) values. Study 5 (N = 123) examined correlations between spontaneous attitude toward power (vs. universalism) values, spontaneous importance toward power (vs. universalism) values, and spontaneous prejudice toward Black African people. Spontaneous positivity toward power (vs. universalism) values was associated with spontaneous negativity toward minorities and predicted gender bias in a decision task, whereas the explicit measures did not. These results indicate that the implicit assessment of evaluative responses attached to human values helps to model value-attitude-behavior relations. © 2016 The Authors. Journal of Personality Published by Wiley Periodicals, Inc.

  4. Spontaneous and superfluid chiral edge states in exciton-polariton condensates

    Science.gov (United States)

    Sigurdsson, H.; Li, G.; Liew, T. C. H.

    2017-09-01

    We present a scheme of interaction-induced topological band structures based on the spin anisotropy of exciton-polaritons in semiconductor microcavities. We predict theoretically that this scheme allows the engineering of topological gaps, without requiring a magnetic field or strong spin-orbit interaction (transverse electric-transverse magnetic splitting). Under nonresonant pumping we find that an initially topologically trivial system undergoes a topological transition upon the spontaneous breaking of phase symmetry associated with polariton condensation. Under either nonresonant or resonant coherent pumping we find that it is also possible to engineer a topological dispersion that is linear in wave vector—a property associated with polariton superfluidity.

  5. Increasing Benefit of Magnetic Resonance Imaging in Multiple Sclerosis

    International Nuclear Information System (INIS)

    Pyhtinen, J.; Karttunen, A.; Tikkakoski, T.

    2006-01-01

    Magnetic resonance imaging (MRI) has emerged as an essential tool of multiple sclerosis (MS) diagnosis and has opened up completely new prospects in MS research and treatment trials. It is a sensitive method that gives direct evidence of tissue pathology and has greatly increased our knowledge of MS. In clinical work, MRI is used to confirm and exclude the diagnosis of MS. The international recommendation is that every suspected MS patient should undergo at least one brain MRI. T2-weighted images are the standard tool in clinical work, and functional imaging methods are mainly used in MS research. The subtypes and the course of the disease cause variation in MRI findings. Here, we present a general overview of MR findings in MS. Brain, magnetic resonance imaging, multiple sclerosis, spinal cord

  6. Increasing Benefit of Magnetic Resonance Imaging in Multiple Sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Pyhtinen, J.; Karttunen, A.; Tikkakoski, T. [Radiologian Klinikka, Oulu (Finland)

    2006-11-15

    Magnetic resonance imaging (MRI) has emerged as an essential tool of multiple sclerosis (MS) diagnosis and has opened up completely new prospects in MS research and treatment trials. It is a sensitive method that gives direct evidence of tissue pathology and has greatly increased our knowledge of MS. In clinical work, MRI is used to confirm and exclude the diagnosis of MS. The international recommendation is that every suspected MS patient should undergo at least one brain MRI. T2-weighted images are the standard tool in clinical work, and functional imaging methods are mainly used in MS research. The subtypes and the course of the disease cause variation in MRI findings. Here, we present a general overview of MR findings in MS. Brain, magnetic resonance imaging, multiple sclerosis, spinal cord.

  7. Magnetic anisotropy study of UGe2in a static high magnetic field

    International Nuclear Information System (INIS)

    Sakon, T; Saito, S; Koyama, K; Awaji, S; Sato, I; Nojima, T; Watanabe, K; Motokawa, M; Sato, N K

    2006-01-01

    UGe 2 has orthorhombic C mmm crystalline symmetry and shows ferromagnetic Heavy-Fermion (HF) Superconductor, which provides superconductivity under pressure in the range from 1.0 GPa to 1.5 GPa. Magnetic field dependence of magnetization shows strong magnetic anisotropy. When a magnetic field is applied parallel to easy axis (a-axis), magnetization presents ferromagnetic behavior. At 4.2 K, which is much lower than the Curie temperature T c = 54 K. Spontaneous magnetization is 1.4 μ B /U, and the magnetization gradually increase with increasing field. On the contrary, when a field is applied parallel to hard axis (b-axis or c-axis), magnetization increases linearly with increasing magnetic field. As for H//b-axis, magnetization is 0.23 μ B /U even at 27 T. Magnetocrystalline anisotropy constant is obtained as 230 [T μ B ] 3.4[kJ/kg] at 4.2 K. This value is comparable with rare-earth magnet Nd 2 Fe 17 , which is typical strongly correlated ferromagnet

  8. Spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Cardwell, C.; Cox, I.; Baldey, A.

    2002-01-01

    Full text: A 49-year old female presented with severe postural headache with no history of trauma. A Computed Tomography (CT) study of the brain demonstrated abnormal meningeal enhancement raising the possibility of leptomeningeal metastases. The patient was then referred to Magnetic Resonance Imaging (MRI) which demonstrated diffuse smooth dural enhancement with ancillary findings characteristic of spontaneous intracranial hypotension. The patient was then referred to Nuclear Medicine to confirm the diagnosis and localise the presumed leak 400MBq of 99mTc DTPA was injected via lumbar puncture into the L3-L4 subarachnoid space Posterior images of the spine were taken with a GE XRT single head gamma camera at 1 and 4 hours post administration of radionuclide. Images demonstrated abnormal early arrival of radionuclide in the kidneys and bladder at 1 hour and abnormal leak of tracer was demonstrate at the level of the first thoracic vertebra on the right side at 4 hours. This confirmed CSF leak at this level. Consequently the patient underwent a blood patch and her symptoms resolved. Spontaneous Intracranial Hypotension is a syndrome often unrecognised presenting with symptoms including severe postural headache neck stiffness nausea vomiting tinnitus and vertigo. The diagnosis is frequently suspected from findings on MRI, but Nuclear Medicine CSF imaging provides a readily available and cost effective method for confirming the diagnosis, and for making the diagnosis in patients who are unsuitable for or do not have access to MRI. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  9. Spontaneous intracranial hypotension

    Energy Technology Data Exchange (ETDEWEB)

    Cardwell, C; Cox, I; Baldey, A [St. F.X. Cabrini Hospital, VIC (Australia). Departments of Nuclear Medicine and Magnetic Resonance Imaging

    2002-07-01

    Full text: A 49-year old female presented with severe postural headache with no history of trauma. A Computed Tomography (CT) study of the brain demonstrated abnormal meningeal enhancement raising the possibility of leptomeningeal metastases. The patient was then referred to Magnetic Resonance Imaging (MRI) which demonstrated diffuse smooth dural enhancement with ancillary findings characteristic of spontaneous intracranial hypotension. The patient was then referred to Nuclear Medicine to confirm the diagnosis and localise the presumed leak 400MBq of 99mTc DTPA was injected via lumbar puncture into the L3-L4 subarachnoid space Posterior images of the spine were taken with a GE XRT single head gamma camera at 1 and 4 hours post administration of radionuclide. Images demonstrated abnormal early arrival of radionuclide in the kidneys and bladder at 1 hour and abnormal leak of tracer was demonstrate at the level of the first thoracic vertebra on the right side at 4 hours. This confirmed CSF leak at this level. Consequently the patient underwent a blood patch and her symptoms resolved. Spontaneous Intracranial Hypotension is a syndrome often unrecognised presenting with symptoms including severe postural headache neck stiffness nausea vomiting tinnitus and vertigo. The diagnosis is frequently suspected from findings on MRI, but Nuclear Medicine CSF imaging provides a readily available and cost effective method for confirming the diagnosis, and for making the diagnosis in patients who are unsuitable for or do not have access to MRI. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc.

  10. Preparation and oil absorption properties of magnetic melamine sponge

    Science.gov (United States)

    Lei, LUO; Jia-qi, HU; Na, LV

    2017-12-01

    The magnetic melamine sponge (MS-Fe3O4) with magnetic response and high hydrophobicity was fabricated by two-step method. First, the magnetic nano-particles were fixed on the skeleton of melamine sponge (MS) using 3-hydroxytyramine hydrochloride and 1-dodecanethiol, then hydrophobicity modified with octadecyltrichlorosilane (OTS). The structures and chemical compositions of MS and MS-Fe3O4 were characterized by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD) and scanning electron microscopy (SEM). The wettability of the sample was obtained by using contact angle analysis system. MS-Fe3O4 endowed with outstanding selectivity and excellent oil absorption capacities, which can be widely used in absorbing various sorts of oil. The oil absorption capacities for crude oil, diesel oil, lubricating oil, soybean oil and peanut oil were 71g/g, 51g/g, 62g/g, 54g/g, 57g/g. In addition, MS-Fe3O4 showed excellent recyclability which can be forecasted as an ideal candidate for oil-water separation.

  11. Evolution of structural, magnetic and transport behavior by Pr doping in SrRuO3

    Science.gov (United States)

    Gupta, Renu; Pramanik, A. K.

    2018-05-01

    Here we report the evolution of structural, magnetic and transport behavior in perovskite based ruthenates Sr1-xPrxRuO3 (x=0.0 and 0.1). The substitution of Pr on Sr site retains orthorhombic structure while we find the slight change in structural parameters. The SrRuO3 has itinerant ferromagnet (FM) type nature of ordering temperature ˜160 K and below the transition temperature showing large bifurcation between ZFC and FC magnetization. By Pr doping, the magnetic moment decreases with decreasing bifurcation of ZFC and FC. The ZFC data show three distinct peaks (three transition temperature; TM1,TM2 and TM3). The magnetization study of both the samples, at high temperature fitted with modified CWL showing the decreasing value of ordering temperature by Pr doping matches close to TM2. The low-temperature isothermal magnetization M (H) data show that the high field saturation moment has decreased by Pr doping. The Arrott plot gives spontaneous magnetization (Ms) which is also decreased by Pr substitution. Evolution of Rhodes-Wohlfarth ratio value increases, which suggests that FM in this system evolves toward the more itinerant type by Pr doping. The electrical resistivity ρ(T) of both the samples show metallic behavior, in the all temperature range and ρ(T) increases by Pr doping while around below 45 K, the resistivity decreases by Pr doping and this crossing temperature also matches with ZFC data.

  12. Rapid Spontaneously Resolving Acute Subdural Hematoma

    Science.gov (United States)

    Gan, Qi; Zhao, Hexiang; Zhang, Hanmei; You, Chao

    2017-01-01

    Introduction: This study reports a rare patient of a rapid spontaneously resolving acute subdural hematoma. In addition, an analysis of potential clues for the phenomenon is presented with a review of the literature. Patient Presentation: A 1-year-and-2-month-old boy fell from a height of approximately 2 m. The patient was in a superficial coma with a Glasgow Coma Scale of 8 when he was transferred to the authors’ hospital. Computed tomography revealed the presence of an acute subdural hematoma with a midline shift beyond 1 cm. His guardians refused invasive interventions and chose conservative treatment. Repeat imaging after 15 hours showed the evident resolution of the hematoma and midline reversion. Progressive magnetic resonance imaging demonstrated the complete resolution of the hematoma, without redistribution to a remote site. Conclusions: Even though this phenomenon has a low incidence, the probability of a rapid spontaneously resolving acute subdural hematoma should be considered when patients present with the following characteristics: children or elderly individuals suffering from mild to moderate head trauma; stable or rapidly recovered consciousness; and simple acute subdural hematoma with a moderate thickness and a particularly low-density band in computed tomography scans. PMID:28468224

  13. Weak cation magnetic separation technology and MALDI-TOF-MS in screening serum protein markers in primary type I osteoporosis.

    Science.gov (United States)

    Shi, X L; Li, C W; Liang, B C; He, K H; Li, X Y

    2015-11-30

    We investigated weak cation magnetic separation technology and matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) in screening serum protein markers of primary type I osteoporosis. We selected 16 postmenopausal women with osteoporosis and nine postmenopausal women as controls to find a new method for screening biomarkers and establishing a diagnostic model for primary type I osteoporosis. Serum samples were obtained from controls and patients. Serum protein was extracted with the WCX protein chip system; protein fingerprints were examined using MALDI-TOF-MS. The preprocessed and model construction data were handled by the ProteinChip system. The diagnostic models were established using a genetic arithmetic model combined with a support vector machine (SVM). The SVM model with the highest Youden index was selected. Combinations with the highest accuracy in distinguishing different groups of data were selected as potential biomarkers. From the two groups of serum proteins, 123 cumulative MS protein peaks were selected. Significant intensity differences in the protein peaks of 16 postmenopausal women with osteoporosis were screened. The difference in Youden index between the four groups of protein peaks showed that the highest peaks had mass-to-charge ratios of 8909.047, 8690.658, 13745.48, and 15114.52. A diagnosis model was established with these four markers as the candidates, and the model specificity and sensitivity were found to be 100%. Two groups of specimens in the SVM results on the scatterplot were distinguishable. We established a diagnosis model, and provided a new serological method for screening and diagnosis of osteoporosis with high sensitivity and specificity.

  14. Spontaneous phase transitions in magnetic films with a modulated structure

    International Nuclear Information System (INIS)

    Arzamastseva, G. V.; Evtikhov, M. G.; Lisovskii, F. V.; Mansvetova, E. G.

    2011-01-01

    The influence of monoperiodic and biperiodic bias fields on the nucleation of domain structures in quasi-uniaxial magnetic films near the Curie point has been studied experimentally. The main types of observed nonuniform magnetic moment distributions have been established and chains of a devil’s staircase phase transitions are shown to be realized when the films are slowly cooled.

  15. Disability in progressive MS is associated with T2 lesion changes

    DEFF Research Database (Denmark)

    Ammitzbøll, Cecilie; Dyrby, Tim Bjørn; Lyksborg, Mark

    2017-01-01

    Background: Progressive multiple sclerosis (MS) is characterized by diffuse changes on brain magnetic resonance imaging (MRI), which complicates the use of MRI as a diagnostic and prognostic marker. The relationship between MRI measures (conventional and non-conventional) and clinical disability...... in progressive MS therefore warrants further investigation. Objective: To investigate the relationship between clinical disability and MRI measures in patients with progressive MS. Methods: Data from 93 primary and secondary progressive MS patients who had participated in 3 phase 2 clinical trials were included...... matter. Disability was assessed by the Expanded Disability Status Scale (EDSS) and the MS functional composite. Results: T2 lesion volume was associated with impairment by all clinical measures. MD and MTR in T2 lesions were significantly related to disability, and lower FA values correlated with worse...

  16. An adolescent with prolapsed omentum per rectum: Spontaneous rectal perforation managed laparoscopically

    Directory of Open Access Journals (Sweden)

    Ameet Kumar

    2017-01-01

    Full Text Available Spontaneous rupture of the rectum is a rare occurrence. A total laparoscopic approach to rectal perforation has only occasionally been reported. We report an unusual case of a young boy who developed a spontaneous rupture of the rectum following a trivial fall. A magnetic resonance imaging revealed a tear in the rectum at the peritoneal reflection with the omentum plugging it. He denied any history of rectal instrumentation or abnormal sexual activity. He had no history of constipation or rectal prolapse. The tear was repaired laparoscopically and a covering loop sigmoid colostomy was added. He made an uneventful post-operative recovery. Spontaneous rupture of the rectum can occur in younger age groups and even in the absence of significant trauma. One needs to diligently bring out a history of rectal trauma. Equally important is to rule out any underlying pathological condition. A laparoscopic approach is feasible, especially in early cases.

  17. Uncovering intrinsic modular organization of spontaneous brain activity in humans.

    Directory of Open Access Journals (Sweden)

    Yong He

    Full Text Available The characterization of topological architecture of complex brain networks is one of the most challenging issues in neuroscience. Slow (<0.1 Hz, spontaneous fluctuations of the blood oxygen level dependent (BOLD signal in functional magnetic resonance imaging are thought to be potentially important for the reflection of spontaneous neuronal activity. Many studies have shown that these fluctuations are highly coherent within anatomically or functionally linked areas of the brain. However, the underlying topological mechanisms responsible for these coherent intrinsic or spontaneous fluctuations are still poorly understood. Here, we apply modern network analysis techniques to investigate how spontaneous neuronal activities in the human brain derived from the resting-state BOLD signals are topologically organized at both the temporal and spatial scales. We first show that the spontaneous brain functional networks have an intrinsically cohesive modular structure in which the connections between regions are much denser within modules than between them. These identified modules are found to be closely associated with several well known functionally interconnected subsystems such as the somatosensory/motor, auditory, attention, visual, subcortical, and the "default" system. Specifically, we demonstrate that the module-specific topological features can not be captured by means of computing the corresponding global network parameters, suggesting a unique organization within each module. Finally, we identify several pivotal network connectors and paths (predominantly associated with the association and limbic/paralimbic cortex regions that are vital for the global coordination of information flow over the whole network, and we find that their lesions (deletions critically affect the stability and robustness of the brain functional system. Together, our results demonstrate the highly organized modular architecture and associated topological properties in

  18. A study on phthalate metabolites, bisphenol A and nonylphenol in the urine of Chinese women with unexplained recurrent spontaneous abortion

    International Nuclear Information System (INIS)

    Peng, Fanli; Ji, Wenliang; Zhu, Feng; Peng, Danhong; Yang, Miao; Liu, Ran; Pu, Yuepu; Yin, Lihong

    2016-01-01

    Humans are widely exposed to phthalates, bisphenol A and nonylphenol owing to the ubiquitous use of these chemicals in consumer products. Increasing attention has been paid to exposure to phthalates, bisphenol A and nonylphenol because of their potential adverse effects on human fertility. A validated method was developed to investigate the three classes of environmental estrogen, mentioned above, in the urine of Chinese women of Nanjing area with unexplained recurrent spontaneous abortion. Solid-phase extraction coupled with ultra performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) was used. In this method, amounts of bisphenol A (BPA), nonylphenol (NP) and four phthalate metabolites, mono-n-butyl phthalate (MBP), mono-isobutyl phthalate (MiBP), mono-benzyl phthalate (MBzP) and mono-2-ethylhexyl phthalate (MEHP), along with their isotope labeled internal standards, were measured using UPLC-MS/MS operated in negative electrospray ionization multiple reaction monitoring mode. The limits of detection were 0.3 ng/mL for the four phthalate metabolites, and 0.5 ng/mL for bisphenol A and nonylphenol. For women with unexplained recurrent spontaneous abortion, the mean concentrations of MBP, MiBP, MBzP, MEHP, BPA and 4-n-NP were 6.52±6.04, 5.51±4.19, 0.53±0.42, 10.12±4.16, 7.13±7.42, 0.41±0.49 ng/mL (mean±SD), respectively. For the control group, the mean concentrations of the corresponding analytes were 4.15±3.57, 2.96±3.30, 0.46±0.49, 6.50±2.81, 4.43±2.23,0.48±0.43 ng/mL (mean±SD), respectively. Levels of MiBP and MEHP were significantly different between the two groups, using Wilcoxon rank sum tests. This method can be applied in epidemiological studies to explore the association between exposure to environmental estrogens and relevant adverse outcomes. - Highlights: • Studied on the exposure level of six analytes in Chinese women with unexplained recurrent spontaneous abortion. • Differences in MEHP and MiBP urine levels were

  19. A study on phthalate metabolites, bisphenol A and nonylphenol in the urine of Chinese women with unexplained recurrent spontaneous abortion

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Fanli [Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009 (China); Ji, Wenliang; Zhu, Feng [Jiangsu Center for Disease Control and Prevention, Nanjing 210009 (China); Peng, Danhong [Department of Obstetrics and Gynecology, Zhong Da Hospital, School of Medicine, Southeast University, Nanjing 210009 (China); Yang, Miao; Liu, Ran; Pu, Yuepu [Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009 (China); Yin, Lihong, E-mail: lhyin@seu.edu.cn [Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Public Health, Southeast University, Nanjing 210009 (China)

    2016-10-15

    Humans are widely exposed to phthalates, bisphenol A and nonylphenol owing to the ubiquitous use of these chemicals in consumer products. Increasing attention has been paid to exposure to phthalates, bisphenol A and nonylphenol because of their potential adverse effects on human fertility. A validated method was developed to investigate the three classes of environmental estrogen, mentioned above, in the urine of Chinese women of Nanjing area with unexplained recurrent spontaneous abortion. Solid-phase extraction coupled with ultra performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) was used. In this method, amounts of bisphenol A (BPA), nonylphenol (NP) and four phthalate metabolites, mono-n-butyl phthalate (MBP), mono-isobutyl phthalate (MiBP), mono-benzyl phthalate (MBzP) and mono-2-ethylhexyl phthalate (MEHP), along with their isotope labeled internal standards, were measured using UPLC-MS/MS operated in negative electrospray ionization multiple reaction monitoring mode. The limits of detection were 0.3 ng/mL for the four phthalate metabolites, and 0.5 ng/mL for bisphenol A and nonylphenol. For women with unexplained recurrent spontaneous abortion, the mean concentrations of MBP, MiBP, MBzP, MEHP, BPA and 4-n-NP were 6.52±6.04, 5.51±4.19, 0.53±0.42, 10.12±4.16, 7.13±7.42, 0.41±0.49 ng/mL (mean±SD), respectively. For the control group, the mean concentrations of the corresponding analytes were 4.15±3.57, 2.96±3.30, 0.46±0.49, 6.50±2.81, 4.43±2.23,0.48±0.43 ng/mL (mean±SD), respectively. Levels of MiBP and MEHP were significantly different between the two groups, using Wilcoxon rank sum tests. This method can be applied in epidemiological studies to explore the association between exposure to environmental estrogens and relevant adverse outcomes. - Highlights: • Studied on the exposure level of six analytes in Chinese women with unexplained recurrent spontaneous abortion. • Differences in MEHP and MiBP urine levels were

  20. Time course of the hemodynamic responses to aortic depressor nerve stimulation in conscious spontaneously hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Durand, M.T.; Mota, A.L. [Departamento de Fisiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Barale, A.R. [Instituto de Ciências Biomédicas, Universidade Federal de Uberlândia, Uberlândia, MG (Brazil); Castania, J.A.; Fazan, R. Jr.; Salgado, H.C. [Departamento de Fisiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2012-03-16

    The time to reach the maximum response of arterial pressure, heart rate and vascular resistance (hindquarter and mesenteric) was measured in conscious male spontaneously hypertensive (SHR) and normotensive control rats (NCR; Wistar; 18-22 weeks) subjected to electrical stimulation of the aortic depressor nerve (ADN). The parameters of stimulation were 1 mA intensity and 2 ms pulse length applied for 5 s, using frequencies of 10, 30, and 90 Hz. The time to reach the hemodynamic responses at different frequencies of ADN stimulation was similar for SHR (N = 15) and NCR (N = 14); hypotension = NCR (4194 ± 336 to 3695 ± 463 ms) vs SHR (3475 ± 354 to 4494 ± 300 ms); bradycardia = NCR (1618 ± 152 to 1358 ± 185 ms) vs SHR (1911 ± 323 to 1852 ± 431 ms), and the fall in hindquarter vascular resistance = NCR (6054 ± 486 to 6550 ± 847 ms) vs SHR (4849 ± 918 to 4926 ± 646 ms); mesenteric = NCR (5574 ± 790 to 5752 ± 539 ms) vs SHR (5638 ± 648 to 6777 ± 624 ms). In addition, ADN stimulation produced baroreflex responses characterized by a faster cardiac effect followed by a vascular effect, which together contributed to the decrease in arterial pressure. Therefore, the results indicate that there is no alteration in the conduction of the electrical impulse after the site of baroreceptor mechanical transduction in the baroreflex pathway (central and/or efferent) in conscious SHR compared to NCR.

  1. Time course of the hemodynamic responses to aortic depressor nerve stimulation in conscious spontaneously hypertensive rats

    International Nuclear Information System (INIS)

    Durand, M.T.; Mota, A.L.; Barale, A.R.; Castania, J.A.; Fazan, R. Jr.; Salgado, H.C.

    2012-01-01

    The time to reach the maximum response of arterial pressure, heart rate and vascular resistance (hindquarter and mesenteric) was measured in conscious male spontaneously hypertensive (SHR) and normotensive control rats (NCR; Wistar; 18-22 weeks) subjected to electrical stimulation of the aortic depressor nerve (ADN). The parameters of stimulation were 1 mA intensity and 2 ms pulse length applied for 5 s, using frequencies of 10, 30, and 90 Hz. The time to reach the hemodynamic responses at different frequencies of ADN stimulation was similar for SHR (N = 15) and NCR (N = 14); hypotension = NCR (4194 ± 336 to 3695 ± 463 ms) vs SHR (3475 ± 354 to 4494 ± 300 ms); bradycardia = NCR (1618 ± 152 to 1358 ± 185 ms) vs SHR (1911 ± 323 to 1852 ± 431 ms), and the fall in hindquarter vascular resistance = NCR (6054 ± 486 to 6550 ± 847 ms) vs SHR (4849 ± 918 to 4926 ± 646 ms); mesenteric = NCR (5574 ± 790 to 5752 ± 539 ms) vs SHR (5638 ± 648 to 6777 ± 624 ms). In addition, ADN stimulation produced baroreflex responses characterized by a faster cardiac effect followed by a vascular effect, which together contributed to the decrease in arterial pressure. Therefore, the results indicate that there is no alteration in the conduction of the electrical impulse after the site of baroreceptor mechanical transduction in the baroreflex pathway (central and/or efferent) in conscious SHR compared to NCR

  2. Acute, Nontraumatic Spontaneous Spinal Subdural Hematoma: A Case Report and Systematic Review of the Literature

    Science.gov (United States)

    Abel, Taylor J.

    2017-01-01

    Spontaneous spinal subdural hematoma (sSDH) is a rare condition outright. Moreover, cases that occur spontaneously in the absence of an identifiable etiology are considerably less common and remain poorly understood. Here, we present the case of a 43-year-old man with spontaneous sSDH presenting with acute onset low back pain and paraplegia. Urgent magnetic resonance imaging identified a dorsal SDH from T8 to T11 with compression of the spinal cord. Emergent T8–T10 laminectomies with intradural exploration and hematoma evacuation were performed. However, despite prompt identification and appropriate action, the patient's recovery was modest and significant disability remained at discharge. This unique and unusual case demonstrates that spontaneous sSDH requires prompt surgical treatment to minimize associated morbidity and supports the association between the presence of severe neurological deficits upon initial presentation with less favorable outcomes. We performed a comprehensive systematic review of spontaneous sSDH of unknown etiology, which demonstrates that emergent surgical intervention is indicated for patients presenting with severe neurological deficits and the presence of these deficits is predictive of poor neurological outcome. Furthermore, conservative management should be considered in patients presenting with mild neurological deficits as spontaneous resolution followed by favorable neurological outcomes is often observed in these patients. PMID:29441210

  3. Magnetic Viscosity for Cyclostratigraphic Logging of Argillaceous Sediment

    Directory of Open Access Journals (Sweden)

    Alain Tabbagh

    2009-09-01

    Full Text Available Magnetic susceptibility (MS is currently used as a directly representative proxy for the study of climatic variations, and for cyclostratigraphic studies. It depends on the concentration of magnetic minerals in the rocks, but does not allow identifying the magnetic minerals. In the case of argillaceous sediments, the paramagnetism of clay particles often plays a major role in determining the magnitude of their magnetic susceptibility, while the presence of ferrimagnetic iron oxides or sulfides cannot be assessedusing susceptibility measurements alone. Among the different methods that can be used to detect ferrimagnetic particles magnetic viscosity (MV characterizing the delay corresponding to the acquisition or loss of induced magnetization, has the same advantages as MS. Itsmeasurement is direct, rapid and has been proven to be very efficient in detecting the presence of secondary ferrimagnetic minerals in soils. A MV measurement technique was tested on cores taken from a borehole, in Callovian-Oxfordian formations in the eastern Paris Basin (France (Fig. 1. Although the MV values are very small, they have cyclic variations of which strongest values are found at the base of the Lower Oxfordian. These values, when correlated to MS,Gamma Ray (GR and a sequential interpretation of a borehole drilled close-by are found to be associated with the maximum clay fraction in the core samples, a MS maximum, and a major transgression event. Consequently, a significant increase in ferrimagnetic minerals can be associated with this event.

  4. Interaction of transcranial magnetic stimulation and electrical transmastoid stimulation in human subjects

    DEFF Research Database (Denmark)

    Taylor, Janet L; Petersen, Nicolas Caesar; Butler, Jane E

    2002-01-01

    Transcranial magnetic stimulation activates corticospinal neurones directly and transsynaptically and hence, activates motoneurones and results in a response in the muscle. Transmastoid stimulation results in a similar muscle response through activation of axons in the spinal cord. This study...... was designed to determine whether the two stimuli activate the same descending axons. Responses to transcranial magnetic stimuli paired with electrical transmastoid stimuli were examined in biceps brachii in human subjects. Twelve interstimulus intervals (ISIs) from -6 ms (magnet before transmastoid) to 5 ms......-wave, facilitation still occurred at ISIs of -6 and -5 ms and depression of the paired response at ISIs of 0, 1, 4 and 5 ms. The interaction of the response to transmastoid stimulation with the multiple descending volleys elicited by magnetic stimulation of the cortex is complex. However, depression of the response...

  5. Magnetic resonance techniques for investigation of multiple sclerosis

    Science.gov (United States)

    MacKay, Alex; Laule, Cornelia; Li, David K. B.; Meyers, Sandra M.; Russell-Schulz, Bretta; Vavasour, Irene M.

    2014-11-01

    Multiple sclerosis (MS) is a common neurological disease which can cause loss of vision and balance, muscle weakness, impaired speech, fatigue, cognitive dysfunction and even paralysis. The key pathological processes in MS are inflammation, edema, myelin loss, axonal loss and gliosis. Unfortunately, the cause of MS is still not understood and there is currently no cure. Magnetic resonance imaging (MRI) is an important clinical and research tool for MS. 'Conventional' MRI images of MS brain reveal bright lesions, or plaques, which demark regions of severe tissue damage. Conventional MRI has been extremely valuable for the diagnosis and management of people who have MS and also for the assessment of therapies designed to reduce inflammation and promote repair. While conventional MRI is clearly valuable, it lack pathological specificity and, in some cases, sensitivity to non-lesional pathology. Advanced MR techniques have been developed to provide information that is more sensitive and specific than what is available with clinical scanning. Diffusion tensor imaging and magnetization transfer provide a general but non-specific measure of the pathological state of brain tissue. MR spectroscopy provides concentrations of brain metabolites which can be related to specific pathologies. Myelin water imaging was designed to assess brain myelination and has proved useful for measuring myelin loss in MS. To combat MS, it is crucial that the pharmaceutical industry finds therapies which can reverse the neurodegenerative processes which occur in the disease. The challenge for magnetic resonance researchers is to design imaging techniques which can provide detailed pathological information relating to the mechanisms of MS therapies. This paper briefly describes the pathologies of MS and demonstrates how MS-associated pathologies can be followed using both conventional and advanced MR imaging protocols.

  6. Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods

    Energy Technology Data Exchange (ETDEWEB)

    Keating, Kristina [Rutgers Univ., Newark, NJ (United States). Dept. of Earth and Environmental Sciences; Slater, Lee [Rutgers Univ., Newark, NJ (United States). Dept. of Earth and Environmental Sciences; Ntarlagiannis, Dimitris [Rutgers Univ., Newark, NJ (United States). Dept. of Earth and Environmental Sciences; Williams, Kenneth H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Earth Sciences Division

    2015-02-24

    This documents contains the final report for the project "Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods" (DE-SC0007049) Executive Summary: Our research aimed to develop borehole measurement techniques capable of monitoring subsurface processes, such as changes in pore geometry and iron/sulfur geochemistry, associated with remediation of heavy metals and radionuclides. Previous work has demonstrated that geophysical method spectral induced polarization (SIP) can be used to assess subsurface contaminant remediation; however, SIP signals can be generated from multiple sources limiting their interpretation value. Integrating multiple geophysical methods, such as nuclear magnetic resonance (NMR) and magnetic susceptibility (MS), with SIP, could reduce the ambiguity of interpretation that might result from a single method. Our research efforts entails combining measurements from these methods, each sensitive to different mineral forms and/or mineral-fluid interfaces, providing better constraints on changes in subsurface biogeochemical processes and pore geometries significantly improving our understanding of processes impacting contaminant remediation. The Rifle Integrated Field Research Challenge (IFRC) site was used as a test location for our measurements. The Rifle IFRC site is located at a former uranium ore-processing facility in Rifle, Colorado. Leachate from spent mill tailings has resulted in residual uranium contamination of both groundwater and sediments within the local aquifer. Studies at the site include an ongoing acetate amendment strategy, native microbial populations are stimulated by introduction of carbon intended to alter redox conditions and immobilize uranium. To test the geophysical methods in the field, NMR and MS logging measurements were collected before, during, and after acetate amendment. Next, laboratory NMR, MS, and SIP measurements

  7. Identification of ten new designer drugs by GC-MS, UPLC-QTOF-MS, and NMR as part of a police investigation of a Danish internet company

    DEFF Research Database (Denmark)

    Reitzel, Lotte A; Dalsgaard, Petur Weihe; Müller, Irene B

    2012-01-01

    -QTOF-MS analyses were supplemented by nuclear magnetic resonance (NMR) spectra for the structural elucidation of p-fluoroamphetamine, mephedrone (4-methylmethcathinone), flephedrone (4-fluoromethcathinone), PPP (a-pyrrolidinopropiophenone), MDPV (3,4-methylenedioxypyrovalerone), Bk-MBDB (2-methylamino-1......-(3,4-methylenedioxyphenyl)butan-1-one), pFBT (3-(pfluorobenzoyl)-tropane), and JWH-073 (1-butyl-3-(1-naphthoyl)indol), whereas methylone (3,4-methylenedioxymethcathinone) and N-ethylcathinone matched electron impact-mass spectrometry (EI-MS) library spectra and therefore the screenings were considered sufficient. EI...

  8. Delayed demagnetization jumps in (NdDy)(FeCo)B magnets in a steady-state magnetic field

    Science.gov (United States)

    L'vova, G. L.; Kirman, M. V.; Koplak, O. V.; Kucheryaev, V. V.; Valeev, R. A.; Piskorskii, V. P.; Morgunov, R. B.

    2017-11-01

    Spontaneous demagnetization jumps are observed in sintered magnets (Nd0.6Dy0.4)16(Fe0.77Co0.23)78B6 in a constant magnetic field after a sharp decrease in an external magnetic field from the value corresponding to the saturation to a value close to the coercive force. It is shown that the number of the magnetization jumps is proportional to their amplitudes. A low value of the autocorrelation coefficient between the jump amplitude and the time of its appearance ( R white magnetic noise is observed. The distribution of the magnetic field gradient has been obtained near the sample surface that makes it possible to distinguish domains and the grain magnetization in the dependence on the direction of the texturing of the sintered magnet.

  9. First results from the LIFE project: discovery of two magnetic hot evolved stars

    Science.gov (United States)

    Martin, A. J.; Neiner, C.; Oksala, M. E.; Wade, G. A.; Keszthelyi, Z.; Fossati, L.; Marcolino, W.; Mathis, S.; Georgy, C.

    2018-04-01

    We present the initial results of the Large Impact of magnetic Fields on the Evolution of hot stars (LIFE) project. The focus of this project is the search for magnetic fields in evolved OBA giants and supergiants with visual magnitudes between 4 and 8, with the aim to investigate how the magnetic fields observed in upper main-sequence (MS) stars evolve from the MS until the late post-MS stages. In this paper, we present spectropolarimetric observations of 15 stars observed using the ESPaDOnS instrument of the Canada-France-Hawaii Telescope. For each star, we have determined the fundamental parameters and have used stellar evolution models to calculate their mass, age, and radius. Using the least-squared deconvolution technique, we have produced averaged line profiles for each star. From these profiles, we have measured the longitudinal magnetic field strength and have calculated the detection probability. We report the detection of magnetic fields in two stars of our sample: a weak field of Bl = 1.0 ± 0.2 G is detected in the post-MS A5 star 19 Aur and a stronger field of Bl = -230 ± 10 G is detected in the MS/post-MS B8/9 star HR 3042.

  10. Spontaneous acute spinal subdural hematoma: spontaneous recovery from severe paraparesis--case report and review.

    Science.gov (United States)

    Payer, Michael; Agosti, Reto

    2010-11-01

    Spontaneous idiopathic acute spinal subdural hematomas are highly exceptional. Neurological symptoms are usually severe, and rapid diagnosis with MRI is mandatory. Surgical evacuation has frequently been used therapeutically; however, spontaneous recovery in mild cases has also been reported. We present a case of spontaneous recovery from severe paraparesis after spontaneous acute SSDH, and review the English-speaking literature.

  11. Observation of Various and Spontaneous Magnetic Skyrmionic Bubbles at Room Temperature in a Frustrated Kagome Magnet with Uniaxial Magnetic Anisotropy

    KAUST Repository

    Hou, Zhipeng; Ren, Weijun; Ding, Bei; Xu, Guizhou; Wang, Yue; Yang, Bing; Zhang, Qiang; Zhang, Ying; Liu, Enke; Xu, Feng; Wang, Wenhong; Wu, Guangheng; Zhang, Xixiang; Shen, Baogen; Zhang, Zhidong

    2017-01-01

    to various external stimuli acting as information carriers in spintronic devices. Here, the first observation of skyrmionic magnetic bubbles with variable topological spin textures formed at room temperature in a frustrated kagome Fe3 Sn2 magnet with uniaxial

  12. A Case of Spontaneous Spinal Epidural Hematoma Mimicking Stroke

    Directory of Open Access Journals (Sweden)

    Emine Rabia Koç

    2014-09-01

    Full Text Available Spontaneous spinal epidural hematoma is an uncommon cause of acute non-traumatic myelopathy and may present with various clinical phenotypes. Focal neurological symptoms can result in overlooking this differential diagnosis in patients presenting with neurological deficits and assuming the diagnosis of a stroke. Therefore, a thorough documentation of patient history is of great importance, since this can reveal symptoms suggestive of a different etiology. Here, we present a case of an 80-year-old female who was admitted with a hemiparesis without cortical or cranial neurological abnormalities. She mentioned of preceding shoulder and neck pain. Diagnosis of epidural hematoma was made by cervical magnetic resonance imaging. Symptoms resolved partially after surgical intervention. Our case illustrates the variation in the clinical presentation of spontaneous spinal epidural hematoma which can be misdiagnosed as stroke. Therefore, in patients with preceding neck, shoulder or interscapular pain and focal neurological deficits, this diagnosis should be included in the differential, particularly when cortical and cranial signs are lacking

  13. Altered spontaneous activity in anisometropic amblyopia subjects: revealed by resting-state FMRI.

    Directory of Open Access Journals (Sweden)

    Xiaoming Lin

    Full Text Available Amblyopia, also known as lazy eye, usually occurs during early childhood and results in poor or blurred vision. Recent neuroimaging studies have found cortical structural/functional abnormalities in amblyopia. However, until now, it was still not known whether the spontaneous activity of the brain changes in amblyopia subjects. In the present study, regional homogeneity (ReHo, a measure of the homogeneity of functional magnetic resonance imaging signals, was used for the first time to investigate changes in resting-state local spontaneous brain activity in individuals with anisometropic amblyopia. Compared with age- and gender-matched subjects with normal vision, the anisometropic amblyopia subjects showed decreased ReHo of spontaneous brain activity in the right precuneus, the left medial prefrontal cortex, the left inferior frontal gyrus, and the left cerebellum, and increased ReHo of spontaneous brain activity was found in the bilateral conjunction area of the postcentral and precentral gyri, the left paracentral lobule, the left superior temporal gyrus, the left fusiform gyrus, the conjunction area of the right insula, putamen and the right middle occipital gyrus. The observed decreases in ReHo may reflect decreased visuo-motor processing ability, and the increases in ReHo in the somatosensory cortices, the motor areas and the auditory area may indicate compensatory plasticity in amblyopia.

  14. Polar cap flow channel events: spontaneous and driven responses

    Directory of Open Access Journals (Sweden)

    P. E. Sandholt

    2010-11-01

    Full Text Available We present two case studies of specific flow channel events appearing at the dusk and/or dawn polar cap boundary during passage at Earth of interplanetary (IP coronal mass ejections (ICMEs on 10 January and 25 July 2004. The channels of enhanced (>1 km/s antisunward convection are documented by SuperDARN radars and dawn-dusk crossings of the polar cap by the DMSP F13 satellite. The relationship with Birkeland currents (C1–C2 located poleward of the traditional R1–R2 currents is demonstrated. The convection events are manifest in ground magnetic deflections obtained from the IMAGE (International Monitor for Auroral Geomagnetic Effects Svalbard chain of ground magnetometer stations located within 71–76° MLAT. By combining the ionospheric convection data and the ground magnetograms we are able to study the temporal behaviour of the convection events. In the two ICME case studies the convection events belong to two different categories, i.e., directly driven and spontaneous events. In the 10 January case two sharp southward turnings of the ICME magnetic field excited corresponding convection events as detected by IMAGE and SuperDARN. We use this case to determine the ground magnetic signature of enhanced flow channel events (the NH-dusk/By<0 variant. In the 25 July case a several-hour-long interval of steady southwest ICME field (Bz<0; By<0 gave rise to a long series of spontaneous convection events as detected by IMAGE when the ground stations swept through the 12:00–18:00 MLT sector. From the ground-satellite conjunction on 25 July we infer the pulsed nature of the polar cap ionospheric flow channel events in this case. The typical duration of these convection enhancements in the polar cap is 10 min.

  15. Super-high magnetic fields in spatially inhomogeneous plasma

    International Nuclear Information System (INIS)

    Nastoyashchiy, Anatoly F.

    2012-01-01

    The new phenomenon of a spontaneous magnetic field in spatially inhomogeneous plasma is found. The criteria for instability are determined, and both the linear and nonlinear stages of the magnetic field growth are considered; it is shown that the magnetic field can reach a considerable magnitude, namely, its pressure can be comparable with the plasma pressure. Especially large magnetic fields can arise in hot plasma with a high electron density, for example, in laser-heated plasma. In steady-state plasma, the magnetic field can be self-sustaining. The considered magnetic fields may play an important role in thermal insulation of the plasma. (author)

  16. Comparison of spontaneous vs. metronome-guided breathing on assessment of vagal modulation using RR variability.

    Science.gov (United States)

    Bloomfield, D M; Magnano, A; Bigger, J T; Rivadeneira, H; Parides, M; Steinman, R C

    2001-03-01

    R-R interval variability (RR variability) is increasingly being used as an index of autonomic activity. High-frequency (HF) power reflects vagal modulation of the sinus node. Since vagal modulation occurs at the respiratory frequency, some investigators have suggested that HF power cannot be interpreted unless the breathing rate is controlled. We hypothesized that HF power during spontaneous breathing would not differ significantly from HF power during metronome-guided breathing. We measured HF power during spontaneous breathing in 20 healthy subjects and 19 patients with heart disease. Each subject's spontaneous breathing rate was determined, and the calculation of HF power was repeated with a metronome set to his or her average spontaneous breathing rate. There was no significant difference between the logarithm of HF power measured during spontaneous and metronome-guided breathing [4.88 +/- 0.29 vs. 5.29 +/- 0.30 ln(ms(2)), P = 0.32] in the group as a whole and when patients and healthy subjects were examined separately. We did observe a small (9.9%) decrease in HF power with increasing metronome-guided breathing rates (from 9 to 20 breaths/min). These data indicate that HF power during spontaneous and metronome-guided breathing differs at most by very small amounts. This variability is several logarithmic units less than the wide discrepancies observed between healthy subjects and cardiac patients with a heterogeneous group of cardiovascular disorders. In addition, HF power is relatively constant across the range of typical breathing rates. These data indicate that there is no need to control breathing rate to interpret HF power when RR variability (and specifically HF power) is used to identify high-risk cardiac patients.

  17. Analysis of phytochemical variations in dioecious Tinospora cordifolia stems using HPLC/QTOF MS/MS and UPLC/QqQLIT -MS/MS.

    Science.gov (United States)

    Bajpai, Vikas; Singh, Awantika; Chandra, Preeti; Negi, M P S; Kumar, Nikhil; Kumar, Brijesh

    2016-01-01

    The stem of dioecious Tinospora cordifolia (Menispermaceae) is a commonly used traditional Ayurvedic medicine in India having several therapeutic properties. To develop and validate LC-MS methods for the identification and simultaneous quantitation of various secondary metabolites and to study metabolomic variations in the stem of male and female plants. Ethanolic extract of stems were analysed by HPLC/ESI-QTOF-MS/MS for rapid screening of bioactive phytochemicals. High resolution MS and MS/MS in positive ESI mode were used for structural investigation of secondary metabolites. An UPLC/ESI-QqQ(LIT) -MS/MS method in MRM mode was developed and validated for the simultaneous quantitation of five bioactive alkaloids. Identification and characterisation of 36 metabolites including alkaloids, sesquiterpenes and phytoecdysteroids were performed using LC-MS and MS/MS techniques. The bioactive alkaloids such as jatrorrhizine, magnoflorine, isocorydine, palmatine and tetrahydropalmatine were successfully quantified in male and female plants. The mean abundances of magnoflorine jatrorrhizine, and oblongine were significantly (P Phytochemicals in the stem of male and female Tinospora cordifolia showed significant qualitative and quantitative variations. LC-MS and MS/MS methods can be used to differentiate between male and female plants based on their chemical profiles and quantities of the marker bioactive alkaloids. This chemical composition difference was also evident during vegetative stage when there were no male and female flowers. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Determination of Glyphosate Levels in Breast Milk Samples from Germany by LC-MS/MS and GC-MS/MS

    NARCIS (Netherlands)

    Steinborn, Angelika; Alder, Lutz; Michalski, Britta; Zomer, Paul; Bendig, Paul; Martinez, Sandra Aleson; Mol, Hans G.J.; Class, Thomas J.; Costa Pinheiro, Nathalie

    2016-01-01

    This study describes the validation and application of two independent analytical methods for the determination of glyphosate in breast milk. They are based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS), respectively. For

  19. Training-induced inversion of spontaneous exchange bias field on La{sub 1.5}Ca{sub 0.5}CoMnO{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Bufaiçal, L., E-mail: lbufaical@ufg.br [Instituto de Física, Universidade Federal de Goiás, 74001-970 Goiânia, GO (Brazil); Finkler, R.; Coutrim, L.T. [Instituto de Física, Universidade Federal de Goiás, 74001-970 Goiânia, GO (Brazil); Pagliuso, P.G. [Instituto de Física “Gleb Wataghin”, UNICAMP, 13083-859 Campinas, SP (Brazil); Grossi, C.; Stavale, F.; Baggio-Saitovitch, E.; Bittar, E.M. [Centro Brasileiro de Pesquisas Físicas, Rua Dr. Xavier Sigaud 150, 22290-180 Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Highlights: • La{sub 1.5}Ca{sub 0.5}CoMnO{sub 6} exhibits spontaneous exchange bias effect at low temperature. • For successive hysteresis cycles it inverts the shift sign from negative to positive. • For a field cooled hysteresis cycle, the exchange bias effect greatly enhances. • Our results are compared to those of the analogue compound La{sub 1.5}Sr{sub 0.5}CoMnO{sub 6}. - Abstract: In this work we report the synthesis and structural, electronic and magnetic properties of La{sub 1.5}Ca{sub 0.5}CoMnO{sub 6} double-perovskite. This is a re-entrant spin cluster material which exhibits a non-negligible negative exchange bias effect when it is cooled in zero magnetic field from an unmagnetized state down to low temperature. X-ray powder diffraction, X-ray photoelectron spectroscopy and magnetometry results indicate mixed valence state at Co site, leading to competing magnetic phases and uncompensated spins at the magnetic interfaces. We compare the results for this Ca-doped material with those reported for the resemblant compound La{sub 1.5}Sr{sub 0.5}CoMnO{sub 6}, and discuss the much smaller spontaneous exchange bias effect observed for the former in terms of its structural and magnetic particularities. For La{sub 1.5}Ca{sub 0.5}CoMnO{sub 6}, when successive magnetization loops are carried, the spontaneous exchange bias field inverts its sign from negative to positive from the first to the second measurement. We discuss this behavior based on the disorder at the magnetic interfaces, related to the presence of a glassy phase. This compound also exhibits a large conventional exchange bias, for which there is no sign inversion of the exchange bias field for consecutive cycles.

  20. Zurek–Kibble Symmetry Breaking Process in Superconducting Rings; Spontaneous Fluxon Formation in Annular Josephson Tunnel Junctions

    DEFF Research Database (Denmark)

    Aarøe, Morten; Monaco, Roberto; Dmitriev, P

    2007-01-01

    We report on new investigations of spontaneous symmetry breaking in non-adiabatic phase transitions. This Zurek-Kibble (ZK) process is mimicked in solid state systems by trapping of magnetic flux quanta, fluxons, in a long annular Josephson tunnel junction quenched through the normal-superconducting...

  1. Development of Immunocapture-LC/MS Assay for Simultaneous ADA Isotyping and Semiquantitation

    Science.gov (United States)

    2016-01-01

    Therapeutic proteins and peptides have potential to elicit immune responses resulting in anti-drug antibodies that can pose problems for both patient safety and product efficacy. During drug development immunogenicity is usually examined by risk-based approach along with specific strategies for developing “fit-for-purpose” bioanalytical approaches. Enzyme-linked immunosorbent assays and electrochemiluminescence immunoassays are the most widely used platform for ADA detection due to their high sensitivity and throughput. During the past decade, LC/MS has emerged as a promising technology for quantitation of biotherapeutics and protein biomarkers in biological matrices, mainly owing to its high specificity, selectivity, multiplexing, and wide dynamic range. In fully taking these advantages, we describe here an immunocapture-LC/MS methodology for simultaneous isotyping and semiquantitation of ADA in human plasma. Briefly, ADA and/or drug-ADA complex is captured by biotinylated drug or anti-drug Ab, immobilized on streptavidin magnetic beads, and separated from human plasma by a magnet. ADA is then released from the beads and subjected to trypsin digestion followed by LC/MS detection of specific universal peptides for each ADA isotype. The LC/MS data are analyzed using cut-point and calibration curve. The proof-of-concept of this methodology is demonstrated by detecting preexisting ADA in human plasma. PMID:27034966

  2. Development of Immunocapture-LC/MS Assay for Simultaneous ADA Isotyping and Semiquantitation.

    Science.gov (United States)

    Chen, Lin-Zhi; Roos, David; Philip, Elsy

    2016-01-01

    Therapeutic proteins and peptides have potential to elicit immune responses resulting in anti-drug antibodies that can pose problems for both patient safety and product efficacy. During drug development immunogenicity is usually examined by risk-based approach along with specific strategies for developing "fit-for-purpose" bioanalytical approaches. Enzyme-linked immunosorbent assays and electrochemiluminescence immunoassays are the most widely used platform for ADA detection due to their high sensitivity and throughput. During the past decade, LC/MS has emerged as a promising technology for quantitation of biotherapeutics and protein biomarkers in biological matrices, mainly owing to its high specificity, selectivity, multiplexing, and wide dynamic range. In fully taking these advantages, we describe here an immunocapture-LC/MS methodology for simultaneous isotyping and semiquantitation of ADA in human plasma. Briefly, ADA and/or drug-ADA complex is captured by biotinylated drug or anti-drug Ab, immobilized on streptavidin magnetic beads, and separated from human plasma by a magnet. ADA is then released from the beads and subjected to trypsin digestion followed by LC/MS detection of specific universal peptides for each ADA isotype. The LC/MS data are analyzed using cut-point and calibration curve. The proof-of-concept of this methodology is demonstrated by detecting preexisting ADA in human plasma.

  3. Finding of pesticides in fashionable fruit juices by LC-MS/MS and GC-MS/MS.

    Science.gov (United States)

    Tran, Kevin; Eide, David; Nickols, Susan M; Cromer, Michele R; Sabaa-Srur, Armando; Smith, Robert E

    2012-10-15

    Products labelled as containing extracts from two mushrooms (cordyceps plus reishi) and the juices from açaí, goji, mangosteen, noni, pomegranate, and sea buckthorn have been analysed for 174 different pesticides, using the validated QuEChERS method for sample preparation and electrospray LC-MS/MS in the positive ion mode for analysis. Pesticides were found in 10 of the 21 samples analysed. Most pesticides found were below the tolerance levels (1-6 μg/g, depending on the pesticide), but some were not. This included boscalid, dimethomorph, iprovalicarb, pyridaben, pyrimethanil, and imazalil, for which there is no tolerance reported or zero tolerance in any fruit. However, genuine açaí that was harvested in the state of Pará and lyophilised in Rio de Janeiro had no detectable pesticides, when analysed by both LC-MS/MS and GC-MS/MS, which can detect 213 more pesticides and industrial chemicals. Likewise no pesticides were found in one sample each of cordyceps plus reishi, sea buckthorn and noni. Published by Elsevier Ltd.

  4. DNA methyltransferase 3A promoter polymorphism is associated with the risk of human spontaneous abortion after assisted reproduction techniques and natural conception.

    Science.gov (United States)

    Liu, Yudong; Zheng, Haiyan; Guo, Pingping; Feng, Shuxian; Zhou, Xingyu; Ye, Desheng; Chen, Xin; Chen, Shiling

    2017-02-01

    The aim of this study was to explore the association of the DNA-methyltransferase (DNMT)-3A and DNMT3B promoter polymorphisms with the risk of human spontaneous abortion after assisted reproduction techniques (ARTs) and natural conception. We collected tissues from women who underwent abortion procedures: (a) chorionic villus samples (CVS) and muscle samples (MS) from spontaneous abortions conceived by ART and natural cycle (study group), n = 152; and (b) CVS and MS from normal early pregnancy and second trimester (control group), n = 155. The single-nucleotide polymorphism (SNP) -448A > G in the DNMT3A promoter region and -149C/T polymorphism of DNMT3B were determined by polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) and confirmed by sequencing. The allele frequency of -448A among pregnancy loss group and control group was 34.2 % vs. 16.5 %, respectively. Compared with GG carriers, the DNMT3A -448AA homozygotes had an about 16-fold increased risk of spontaneous abortion [odds ratio (OR) = 16.130, 95 % confidence interval (CI), 3.665-70.984], and AG heterozygotes had an OR of 2.027 (95 % CI, 1.247-3.293). However, the distribution of -448A > G in individuals derived from ART pregnancies was not statistically significantly compared with those derived from spontaneous pregnancies (P = 0.661). For DNMT3B, we observed genotype frequencies of 100 % (TT) in the study group and the control group. The DNMT3A -448A > G polymorphism may be a novel functional SNP and contribute to its genetic susceptibility to spontaneous abortion in Chinese women, and ART may not affect the distribution of -448A > G in pregnancy loss and normal pregnancy. The observed TT genotype of DMNT3B suggests that this is the predominant genotype of this population. The findings provide new insights into the etiology of human spontaneous abortion.

  5. Measurement of magnetic properties of confined compact toroid plasma (spheromak)

    International Nuclear Information System (INIS)

    Hwang, Fu-Kwun.

    1991-01-01

    The theoretical aspect of the spheromak is described in this paper. The MS machine hardware will be explored along with the formation scheme and diagnostic systems. The magnetic pickup probes, their calibration procedures and the data analysis methods will be discussed. Observations from the probe measurements and magnetic properties of the MS spheromak are considered. The axisymmetric Grad-Shafranov equilibrium code calculations are presented and compared with the measurements. Magnetic helicity and its correlation with the experimental observations is described

  6. Quantitative interpretation of the magnetic susceptibility frequency dependence

    Science.gov (United States)

    Ustra, Andrea; Mendonça, Carlos A.; Leite, Aruã; Jovane, Luigi; Trindade, Ricardo I. F.

    2018-05-01

    Low-field mass-specific magnetic susceptibility (MS) measurements using multifrequency alternating fields are commonly used to evaluate concentration of ferrimagnetic particles in the transition of superparamagnetic (SP) to stable single domain (SSD). In classical palaeomagnetic analyses, this measurement serves as a preliminary assessment of rock samples providing rapid, non-destructive, economical and easy information of magnetic properties. The SP-SSD transition is relevant in environmental studies because it has been associated with several geological and biogeochemical processes affecting magnetic mineralogy. MS is a complex function of mineral-type and grain-size distribution, as well as measuring parameters such as external field magnitude and frequency. In this work, we propose a new technique to obtain quantitative information on grain-size variations of magnetic particles in the SP-SSD transition by inverting frequency-dependent susceptibility. We introduce a descriptive parameter named as `limiting frequency effect' that provides an accurate estimation of MS loss with frequency. Numerical simulations show the methodology capability in providing data fitting and model parameters in many practical situations. Real-data applications with magnetite nanoparticles and core samples from sediments of Poggio le Guaine section of Umbria-Marche Basin (Italy) provide additional information not clearly recognized when interpreting cruder MS data. Caution is needed when interpreting frequency dependence in terms of single relaxation processes, which are not universally applicable and depend upon the nature of magnetic mineral in the material. Nevertheless, the proposed technique is a promising tool for SP-SSD content analyses.

  7. Effects of metal pollutants on magnetic and chemical properties of soils and plant biomass: experimental studies in Environmental Magnetism

    Science.gov (United States)

    Sapkota, Birendra

    Understanding the interactions and effects of biotic and abiotic factors on magnetic parameter measurements used to assess levels of pollutants requires experimental analysis of potential individual parameters. Using magnetic and chemical measurements, three separate experimental studies were conducted in order to evaluate the separate and combined effects of soil composition, atmospheric exposure, and contaminant levels on soil magnetic susceptibility (MS) measurements, plant growth and metal uptake by plants. Experiment 1 examined the effects of incorporating an artificial Fe-rich contaminant into a synthetic soil on surficial soil magnetic properties and plant growth inside a greenhouse. Periodic measurements of surficial soil MS showed significant decreases in MS values in the three treatments (two levels of Fe-contamination and controls), with the greatest reduction in soils with the most contamination, and the least in controls. Three potential causes were suggested: Fe uptake by plants, magnetic minerals transformation, and downward migration of Fe-particles. Some arguments for the first two causes were discussed; however, the third possibility was separately evaluated in the second and third experiments. In the follow-up study (Experiment 2) conducted to examine the effects of ambient atmospheric pollution on magnetic and chemical properties of soils and plant biomass, the overall surficial soil MS was found to be significantly higher in synthetic soils exposed to a natural atmosphere in comparison to controls placed in a greenhouse. Root biomass samples taken from the exposed soils had much higher trace/heavy metal concentrations. Such increases in soil MS and bioavailability of metals in the exposed soils indicate that atmospheric pollution affected the soil and plants grown in there. Microscopic observations of Fe-rich particles from the post-harvest exposed soil revealed morphologies similar to Fe-containing particulates from power plants and

  8. Investigation on energetics of ex-vessel vapor explosion based on spontaneous nucleation fragmentation

    International Nuclear Information System (INIS)

    Liu, Jie; Koshizuka, Seiichi; Oka, Yoshiaki

    2002-01-01

    A computer code PROVER-I is developed for propagation phase of vapor explosion. A new thermal fragmentation model is proposed with three kinds of time scale for modeling instant fragmentation, spontaneous nucleation fragmentation and normal boiling fragmentation. The energetics of ex-vessel vapor explosion is investigated based on different fragmentation models. A higher pressure peak and a larger mechanical energy conversion ratio are obtained by spontaneous nucleation fragmentation. A smaller energy conversion ratio results from normal boiling fragmentation. When the delay time in thermal fragmentation model is near 0.0 ms, the pressure propagation behavior tends to be analogous with that in hydrodynamic fragmentation. If the delay time is longer, pressure attenuation occurs at the shock front. The high energy conversion ratio (>4%) is obtained in a small vapor volume fraction together with spontaneous nucleation fragmentation. These results are consistent with fuel-coolant interaction experiments with alumina melt. However, in larger vapor volume fraction conditions (α υ >0.3), the vapor explosion is weak. For corium melt, a coarse mixture with void fraction of more than 30% can be generated in the pre-mixing process because of its physical properties. In the mixture with such a high void fraction the energetic vapor explosion hardly takes place. (author)

  9. Pediatric MS

    Science.gov (United States)

    ... Pediatric MS Share this page Facebook Twitter Email Pediatric MS Pediatric MS Pediatric MS Support Pediatric Providers ... system through the Pediatric MS Support Group . Treating pediatric MS In 2018 the U.S. Food and Drug ...

  10. Volatile Compounds and Lactic Acid Bacteria in Spontaneous Fermented Sourdough

    International Nuclear Information System (INIS)

    Kam, W.Y.; Aida, W.M.W.; Sahilah, A.M.; Maskat, M.Y.

    2011-01-01

    The aim of this study is to identify the predominating lactic acid bacteria (LAB) in a spontaneous fermented wheat sourdough. At the same time, an investigation towards volatile compounds that were produced was also carried out. Lactobacillus plantarum has been identified as the dominant species of lactobacilli with characters of a facultative heterofermentative strain. The generated volatile compounds that were produced during spontaneous fermentation were isolated by solvent extraction method, analysed by gas chromatography (GC), and identified by mass spectrophotometer (MS). Butyric acid has been found to be the main volatile compound with relative abundance of 6.75 % and acetic acid at relative abundance of 3.60 %. Esters that were formed at relatively low amount were butyl formate (1.23 %) and cis 3 hexenyl propionate (0.05 %). Butanol was also found at low amount with relative abundance of 0.60 %. The carbohydrate metabolism of Lactobacillus plantarum may contributed to the production of acetic acid in this study via further catabolism activity on lactic acid that was produced. However, butyric acid was not the major product via fermentation by LAB but mostly carried out by the genus Clostridium via carbohydrate metabolism which needs further investigation. (author)

  11. Recruitment of Perisomatic Inhibition during Spontaneous Hippocampal Activity In Vitro.

    Directory of Open Access Journals (Sweden)

    Anna Beyeler

    Full Text Available It was recently shown that perisomatic GABAergic inhibitory postsynaptic potentials (IPSPs originating from basket and chandelier cells can be recorded as population IPSPs from the hippocampal pyramidal layer using extracellular electrodes (eIPSPs. Taking advantage of this approach, we have investigated the recruitment of perisomatic inhibition during spontaneous hippocampal activity in vitro. Combining intracellular and extracellular recordings from pyramidal cells and interneurons, we confirm that inhibitory signals generated by basket cells can be recorded extracellularly, but our results suggest that, during spontaneous activity, eIPSPs are mostly confined to the CA3 rather than CA1 region. CA3 eIPSPs produced the powerful time-locked inhibition of multi-unit activity expected from perisomatic inhibition. Analysis of the temporal dynamics of spike discharges relative to eIPSPs suggests significant but moderate recruitment of excitatory and inhibitory neurons within the CA3 network on a 10 ms time scale, within which neurons recruit each other through recurrent collaterals and trigger powerful feedback inhibition. Such quantified parameters of neuronal interactions in the hippocampal network may serve as a basis for future characterisation of pathological conditions potentially affecting the interactions between excitation and inhibition in this circuit.

  12. Chip-based magnetic solid phase microextraction coupled with ICP-MS for the determination of Cd and Se in HepG2 cells incubated with CdSe quantum dots.

    Science.gov (United States)

    Yu, Xiaoxiao; Chen, Beibei; He, Man; Wang, Han; Hu, Bin

    2018-03-01

    The quantification of trace Cd and Se in cells incubated with CdSe quantum dots (QDs) is critical to investigate the cytotoxicity of CdSe QDs. In this work, a miniaturized platform, namely chip-based magnetic solid phase microextraction (MSPME) packing with sulfhydryl group functionalized magnetic nanoparticles, was fabricated and combined with inductively coupled plasma mass spectrometry (ICP-MS) for the determination of trace Cd and Se in cells. Under the optimized conditions, the limits of detection (LOD) of the developed chip-based MSPME-ICP-MS system are 2.2 and 21ngL -1 for Cd and Se, respectively. The proposed method is applied successfully to the analysis of total and released small molecular fraction of Cd and Se in Human hepatocellular carcinoma cells (HepG2 cells) incubated with CdSe QDs, and the recoveries for the spiked samples are in the range of 86.0-109%. This method shows great promise to analyze cell samples and the obtained results are instructive to explore the cytotoxicity mechanism of CdSe QDs in cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Spontaneous Reperfusion after In Situ Thromboembolic Stroke in Mice

    Science.gov (United States)

    Cho, Tae-Hee; Bolbos, Radu; Langlois, Jean-Baptiste; Hermitte, Laure; Wiart, Marlène; Berthezène, Yves; Nighoghossian, Norbert

    2012-01-01

    Injection of thrombin into the middle cerebral artery (MCA) of mice has been proposed as a new model of thromboembolic stroke. The present study used sequential multiparametric Magnetic Resonance Imaging (MRI), including Magnetic Resonance Angiography (MRA), Diffusion-Weighted Imaging (DWI) and Perfusion-Weighted Imaging (PWI), to document MCA occlusion, PWI-DWI mismatch, and lesion development. In the first experiment, complete MCA occlusion and reproducible hypoperfusion were obtained in 85% of animals during the first hour after stroke onset. In the second experiment, 80% of animals showed partial to complete reperfusion during a three-hour follow-up. Spontaneous reperfusion thus contributed to the variability in ischemic volume in this model. The study confirmed the value of the model for evaluating new thrombolytic treatments, but calls for extended MRI follow-up at the acute stage in therapeutic studies. PMID:23166825

  14. An Evolutionary Game Theory Model of Spontaneous Brain Functioning.

    Science.gov (United States)

    Madeo, Dario; Talarico, Agostino; Pascual-Leone, Alvaro; Mocenni, Chiara; Santarnecchi, Emiliano

    2017-11-22

    Our brain is a complex system of interconnected regions spontaneously organized into distinct networks. The integration of information between and within these networks is a continuous process that can be observed even when the brain is at rest, i.e. not engaged in any particular task. Moreover, such spontaneous dynamics show predictive value over individual cognitive profile and constitute a potential marker in neurological and psychiatric conditions, making its understanding of fundamental importance in modern neuroscience. Here we present a theoretical and mathematical model based on an extension of evolutionary game theory on networks (EGN), able to capture brain's interregional dynamics by balancing emulative and non-emulative attitudes among brain regions. This results in the net behavior of nodes composing resting-state networks identified using functional magnetic resonance imaging (fMRI), determining their moment-to-moment level of activation and inhibition as expressed by positive and negative shifts in BOLD fMRI signal. By spontaneously generating low-frequency oscillatory behaviors, the EGN model is able to mimic functional connectivity dynamics, approximate fMRI time series on the basis of initial subset of available data, as well as simulate the impact of network lesions and provide evidence of compensation mechanisms across networks. Results suggest evolutionary game theory on networks as a new potential framework for the understanding of human brain network dynamics.

  15. Cine MRI during spontaneous cramps in women with menstrual pain.

    Science.gov (United States)

    Hellman, Kevin M; Kuhn, Caroline S; Tu, Frank F; Dillane, Katlyn E; Shlobin, Nathan A; Senapati, Sangeeta; Zhou, Xiaojie; Li, Wei; Prasad, Pottumarthi V

    2018-05-01

    The lack of noninvasive methods to study dysmenorrhea has resulted in poor understanding of the mechanisms underlying pain, insufficient diagnostic tests, and limited treatment options. To address this knowledge gap, we have developed a magnetic resonance imaging-based strategy for continuously monitoring the uterus in relationship to participants' spontaneous pain perception. The study objective was to evaluate whether magnetic resonance imaging can detect real-time changes in myometrial activity during cramping episodes in women with dysmenorrhea, with a handheld squeeze bulb for pain reporting. Sixteen women with dysmenorrhea and 10 healthy control women both on and off their menses were evaluated with magnetic resonance imaging while not taking analgesic medication. Continuous magnetic resonance imaging was acquired using half-Fourier acquisition single-shot turbo spin echo sequence along with simultaneous reporting of pain severity with a squeeze bulb. Pearson's coefficient was used to compare results between reviewers. Proportional differences between women with dysmenorrhea and controls on/off menses were evaluated with a Fisher exact test. The temporal relationships between signal changes were evaluated with Monte Carlo simulations. Spontaneous progressive decreases in myometrial signal intensity were more frequently observed in women on their menses than in the absence of pain in the same women off their menses or participants without dysmenorrhea (P < .01). Women without reductions in myometrial signal intensity on their menses either had a history of endometriosis or were not in pain. Observations of myometrial events were consistently reported between 2 raters blinded to menstrual pain or day status (r = 0.97, P < .001). Episodes of cramping occurred either immediately before or 32-70 seconds after myometrial signal change onset (P < .05). Transient decreases in myometrial uterine T2-weighted signal intensity can be reliably measured in women with

  16. Mechanisms of magnetic stimulation of central nervous system neurons.

    Directory of Open Access Journals (Sweden)

    Tamar Pashut

    2011-03-01

    Full Text Available Transcranial magnetic stimulation (TMS is a stimulation method in which a magnetic coil generates a magnetic field in an area of interest in the brain. This magnetic field induces an electric field that modulates neuronal activity. The spatial distribution of the induced electric field is determined by the geometry and location of the coil relative to the brain. Although TMS has been used for several decades, the biophysical basis underlying the stimulation of neurons in the central nervous system (CNS is still unknown. To address this problem we developed a numerical scheme enabling us to combine realistic magnetic stimulation (MS with compartmental modeling of neurons with arbitrary morphology. The induced electric field for each location in space was combined with standard compartmental modeling software to calculate the membrane current generated by the electromagnetic field for each segment of the neuron. In agreement with previous studies, the simulations suggested that peripheral axons were excited by the spatial gradients of the induced electric field. In both peripheral and central neurons, MS amplitude required for action potential generation was inversely proportional to the square of the diameter of the stimulated compartment. Due to the importance of the fiber's diameter, magnetic stimulation of CNS neurons depolarized the soma followed by initiation of an action potential in the initial segment of the axon. Passive dendrites affect this process primarily as current sinks, not sources. The simulations predict that neurons with low current threshold are more susceptible to magnetic stimulation. Moreover, they suggest that MS does not directly trigger dendritic regenerative mechanisms. These insights into the mechanism of MS may be relevant for the design of multi-intensity TMS protocols, may facilitate the construction of magnetic stimulators, and may aid the interpretation of results of TMS of the CNS.

  17. Mechanisms of magnetic stimulation of central nervous system neurons.

    Science.gov (United States)

    Pashut, Tamar; Wolfus, Shuki; Friedman, Alex; Lavidor, Michal; Bar-Gad, Izhar; Yeshurun, Yosef; Korngreen, Alon

    2011-03-01

    Transcranial magnetic stimulation (TMS) is a stimulation method in which a magnetic coil generates a magnetic field in an area of interest in the brain. This magnetic field induces an electric field that modulates neuronal activity. The spatial distribution of the induced electric field is determined by the geometry and location of the coil relative to the brain. Although TMS has been used for several decades, the biophysical basis underlying the stimulation of neurons in the central nervous system (CNS) is still unknown. To address this problem we developed a numerical scheme enabling us to combine realistic magnetic stimulation (MS) with compartmental modeling of neurons with arbitrary morphology. The induced electric field for each location in space was combined with standard compartmental modeling software to calculate the membrane current generated by the electromagnetic field for each segment of the neuron. In agreement with previous studies, the simulations suggested that peripheral axons were excited by the spatial gradients of the induced electric field. In both peripheral and central neurons, MS amplitude required for action potential generation was inversely proportional to the square of the diameter of the stimulated compartment. Due to the importance of the fiber's diameter, magnetic stimulation of CNS neurons depolarized the soma followed by initiation of an action potential in the initial segment of the axon. Passive dendrites affect this process primarily as current sinks, not sources. The simulations predict that neurons with low current threshold are more susceptible to magnetic stimulation. Moreover, they suggest that MS does not directly trigger dendritic regenerative mechanisms. These insights into the mechanism of MS may be relevant for the design of multi-intensity TMS protocols, may facilitate the construction of magnetic stimulators, and may aid the interpretation of results of TMS of the CNS.

  18. Spontaneous rupture of the distal iliopsoas tendon: clinical and imaging findings, with anatomic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Lecouvet, Frederic E.; Vande Berg, Bruno C.; Malghem, Jacques [Universite Catholique de Louvain, Department of Radiology and Medical Imaging, Saint Luc University Hospital, Brussels (Belgium); Demondion, Xavier [Centre Hospitalier Universitaire de Lille, Department of Bone Radiology and Laboratory of Anatomy, Lille (France); Leemrijse, Thibaut [Universite Catholique de Louvain, Department of Orthopedic Surgery, Saint Luc University Hospital, Brussels (Belgium); Devogelaer, Jean-Pierre [Universite Catholique de Louvain, Department of Rheumatology, Saint Luc University Hospital, Brussels (Belgium)

    2005-11-01

    We report the clinical and imaging findings in two elderly female patients with spontaneous rupture of the distal iliopsoas tendon from the lesser trochanter of the femur. We emphasize the key contribution of magnetic resonance (MR) imaging to this diagnosis and provide an anatomic correlation. Spontaneous rupture of the distal iliopsoas tendon should be kept in mind in the differential diagnosis of acute groin pain in the elderly. MR imaging enables positive diagnosis, by showing mass effect on the anterior aspect of the hip joint, proximal muscle thickening, and abnormal signal intensity, and by demonstrating interruption of the psoas tendon, whereas the distal insertion of the lateral portion of the iliacus muscle remains muscular and is preserved. (orig.)

  19. Spontaneous and trigger-associated substorms compared: Electrodynamic parameters in the polar ionosphere

    Science.gov (United States)

    Liu, Jun-Ming; Zhang, Bei-Chen; Kamide, Y.; Wu, Zhen-Sen; Hu, Ze-Jun; Yang, Hui-Gen

    2011-01-01

    An attempt is made to study the difference, if any, between the response of the polar ionosphere to spontaneous substorms and that to trigger-associated substorms in terms of electrodynamic parameters including ionospheric current vectors, the electric potential, and the current function. The results show that, in the first approximation, the ionospheric parameters for the two types of substorms are quite similar. It is therefore conceived that spontaneous substorms are not very different from trigger-associated substorms in the development of substorm processes in the magnetosphere-ionosphere system. We demonstrate, however, that spontaneous substorms seem to have a more clearly identifiable growth phase, whereas trigger-associated substorms have a more powerful unloading process. Changes in the current intensity and the electric potential drop across the polar cap in the recovery phase are also quite different from each other. Both the current intensity and the cross-polar cap potential drop show a larger decrease in the recovery phase of trigger-associated substorms, but the potential drop decreases only slightly and the currents in the late morning sector are still strong for spontaneous substorms. We interpret these findings as an indication of the relative importance of the unloading process and the directly driven process in conjunction with the north-south polarity of the interplanetary magnetic field. There still exists a strong directly driven process in the recovery phase of spontaneous substorms. For trigger-associated substorms, however, both the directly driven process and the unloading process become weak after the peak time.

  20. ES-5052 storage devices on magnetic disks for the BESM-4 computer

    International Nuclear Information System (INIS)

    Bezrukova, N.B.; Vinogradov, A.F.; Eliseev, G.N.; Ivanchenko, Z.M.; Pervushov, V.I.; Samojlov, V.N.; Stuk, G.P.; Shchelev, S.A.; Chulkov, N.I.

    1975-01-01

    The basic principles of connection between ES-5052 magnetic disk storage devices and a BESM-4 computer are set forth. The interchange of instructions and guidance information between computer and magnetic disk storage is accomplished through a disk controlling unit. The time taken to find the required cylinder (to pass from track to track) is 20 ms, the access time is 60 to 95 ms. The data transfer rate (512 45-digit machine words) is 20 ms. The total disk storage capacity is equivalent to 250 BESM-4 memory units. The instructions for BESM-4 access to the ES-5052 magnetic disk storage are described

  1. The perception of musical spontaneity in improvised and imitated jazz performances

    Directory of Open Access Journals (Sweden)

    Annerose eEngel

    2011-05-01

    Full Text Available The ability to evaluate spontaneity in human behavior is called upon in the aesthetic appreciation of dramatic arts and music. The current study addresses the behavioral and brain mechanisms that mediate the perception of spontaneity in music performance. In a functional Magnetic Resonance Imaging experiment, 22 jazz musicians listened to piano melodies and judged whether they were improvised or imitated. Judgment accuracy (mean 55%; range 44-65%, which was low but above chance, was positively correlated with musical experience and empathy. Analysis of listeners’ hemodynamic responses revealed that amygdala activation was stronger for improvisations than imitations. This activation correlated with the variability of performance timing and intensity (loudness in the melodies, suggesting that the amygdala is involved in the detection of behavioral uncertainty. An analysis based on the subjective classification of melodies according to listeners’ judgments revealed that a network including the pre-supplementary motor area, frontal operculum, and anterior insula was most strongly activated for melodies judged to be improvised. This may reflect the increased engagement of an action simulation network when melodic predictions are rendered challenging due to perceived instability in the performer’s actions. Taken together, our results suggest that, while certain brain regions in skilled individuals may be generally sensitive to objective cues to spontaneity in human behavior, the ability to evaluate spontaneity accurately depends upon whether an individual’s action-related experience and perspective taking skills enable faithful internal simulation of the given behavior.

  2. The perception of musical spontaneity in improvised and imitated jazz performances.

    Science.gov (United States)

    Engel, Annerose; Keller, Peter E

    2011-01-01

    The ability to evaluate spontaneity in human behavior is called upon in the esthetic appreciation of dramatic arts and music. The current study addresses the behavioral and brain mechanisms that mediate the perception of spontaneity in music performance. In a functional magnetic resonance imaging experiment, 22 jazz musicians listened to piano melodies and judged whether they were improvised or imitated. Judgment accuracy (mean 55%; range 44-65%), which was low but above chance, was positively correlated with musical experience and empathy. Analysis of listeners' hemodynamic responses revealed that amygdala activation was stronger for improvisations than imitations. This activation correlated with the variability of performance timing and intensity (loudness) in the melodies, suggesting that the amygdala is involved in the detection of behavioral uncertainty. An analysis based on the subjective classification of melodies according to listeners' judgments revealed that a network including the pre-supplementary motor area, frontal operculum, and anterior insula was most strongly activated for melodies judged to be improvised. This may reflect the increased engagement of an action simulation network when melodic predictions are rendered challenging due to perceived instability in the performer's actions. Taken together, our results suggest that, while certain brain regions in skilled individuals may be generally sensitive to objective cues to spontaneity in human behavior, the ability to evaluate spontaneity accurately depends upon whether an individual's action-related experience and perspective taking skills enable faithful internal simulation of the given behavior.

  3. Spontaneous mentalizing during an interactive real world task: an fMRI study.

    Science.gov (United States)

    Spiers, Hugo J; Maguire, Eleanor A

    2006-01-01

    There are moments in everyday life when we need to consider the thoughts and intentions of other individuals in order to act in a socially appropriate manner. Most of this mentalizing occurs spontaneously as we go about our business in the complexity of the real world. As such, studying the neural basis of spontaneous mentalizing has been virtually impossible. Here we devised a means to achieve this by employing a unique combination of functional magnetic resonance imaging (fMRI), a detailed and interactive virtual reality simulation of a bustling familiar city, and a retrospective verbal report protocol. We were able to provide insights into the content of spontaneous mentalizing events and identify the brain regions that underlie them. We found increased activity in a number of regions, namely the right posterior superior temporal sulcus, the medial prefrontal cortex and the right temporal pole associated with spontaneous mentalizing. Furthermore, we observed the right posterior superior temporal sulcus to be consistently active during several different subtypes of mentalizing events. By contrast, medial prefrontal cortex seemed to be particularly involved in thinking about agents that were visible in the environment. Our findings show that it is possible to investigate the neural basis of mentalizing in a manner closer to its true context, the real world, opening up intriguing possibilities for making comparisons with those who have mentalizing problems.

  4. Spontaneous Brain Activity Did Not Show the Effect of Violent Video Games on Aggression: A Resting-State fMRI Study

    OpenAIRE

    Wei Pan; Wei Pan; Wei Pan; Xuemei Gao; Shuo Shi; Fuqu Liu; Chao Li

    2018-01-01

    A great many of empirical researches have proved that longtime exposure to violent video game can lead to a series of negative effects. Although research has focused on the neural basis of the correlation between violent video game and aggression, little is known whether the spontaneous brain activity is associated with violent video game exposure. To address this question, we measured the spontaneous brain activity using resting-state functional magnetic resonance imaging (fMRI). We used the...

  5. Spontaneous external gallbladder perforation

    International Nuclear Information System (INIS)

    Noeldge, G.; Wimmer, B.; Kirchner, R.

    1981-01-01

    Spontaneous perforation of the gallbladder is one complication of cholelithiasis. There is a greater occurence of free perforation in the peritoneal cavity with bilary pertonitis, followed by the perforation into the stomach, small intestine and colon. A single case of the nowadays rare spontaneous perforation in and through the abdominal wall will be reported. Spontaneous gallbladder perforation appears nearly asymptomatic in its clinical course because of absent biliary peritonitis. (orig.) [de

  6. Multiple sclerosis (MS) for the urologist: What should urologists know about MS?

    Science.gov (United States)

    Aharony, Shachar; Lam, Ornella; Lapierre, Yves; Corcos, Jacques

    2016-02-01

    Multiple sclerosis (MS) is a unique central nervous system (CNS) inflammatory disease with a broad spectrum of clinical presentations, which are time- and disease progression-related. It usually affects young adults, with a female predominance of 3:1. Men are more likely to develop symptoms at a slightly older age with a more progressive disease course. Diagnosis relies on a combination of clinical, radiological, and laboratory investigations, with a central role of magnetic resonance imaging (MRI). Although the exact etiology is still obscure, the leading hypothesis behind MS relapses is acute inflammatory attacks on CNS myelin and axons. This complex process involves B and T cells together with macrophages and microglia. Genetic and environmental factors are thought to be major contributors to the disease's evolution. MS therapies consist of long-term (immunomodulatory) management, focusing on disease modification, and short-term symptomatic control. Symptomatic treatment includes pharmacological and non-pharmacological methods to protect function and restore quality of life (QoL). The introduction and development of disease-modifying medications provide opportunities to change the face of this disease, enhancing QoL over the long-term. Interferon (INF) and Glatiramer acetate (GLAT) represent first line medications with limited effect and relatively fair safety profile. Newer medications with improved efficacy along with a more hazardous side effect profile are now considered second line therapy. The present review summarizes current knowledge of this frequent disease. Urologists must acquire a deeper understanding for better integration of practice recommendations. © 2015 Wiley Periodicals, Inc.

  7. Spontaneous quasi single helicity regimes in EXTRAP T2R reversed-field pinch

    Science.gov (United States)

    Frassinetti, L.; Brunsell, P. R.; Drake, J. R.; Menmuir, S.; Cecconello, M.

    2007-11-01

    In recent years, good progress toward a better understanding and control of the plasma performance in reversed-field pinch devices has been made. These improvements consist both of the discovery of spontaneous plasma regimes, termed the quasi single helicity (QSH) regime, in which part of the plasma core is no longer stochastic, and of the development of techniques for active control of plasma instabilities. In this paper, a systematic study of spontaneous QSH in the EXTRAP T2R device [P. R. Brunsell, H. Bergsaker, M. Cecconello et al., Plasma Phys. Control. Fusion 43, 1457 (2001)] is presented. In this device, QSH states can occur spontaneously and it is associated with magnetic and thermal structures. A statistical analysis to determine the most favorable experimental conditions to have a transition to the QSH regime will be presented. The results described here are useful to understand the underlying properties of QSH regimes in view of future applications of the QSH active control in EXTRAP T2R; they are also important to have a comparison with the QSH studied in other devices.

  8. Brain Delivery of Drug and MRI Contrast Agent: Detection and Quantitative Determination of Brain Deposition of CPT-Glu Using LC-MS/MS and Gd-DTPA Using Magnetic Resonance Imaging

    Science.gov (United States)

    Tabanor, Kayann; Lee, Phil; Kiptoo, Paul; Choi, In-Young; Sherry, Erica B.; Eagle, Cheyenne Sun; Williams, Todd D.; Siahaan, Teruna J.

    2015-01-01

    Successful treatment and diagnosis of neurological diseases depend on reliable delivery of molecules across the blood-brain barrier (BBB), which restricts penetration of pharmaceutical drugs and diagnostic agents into the brain. Thus, developing new non-invasive strategies to improve drug delivery across the BBB is critically needed. This study was aimed at evaluating the activity of HAV6 peptide (Ac-SHAVSS-NH2) in improving brain delivery of camptothecin-glutamate (CPT-Glu) conjugate and gadolinium-diethylenetriaminepentaacetate (Gd-DTPA) contrast agent in Sprague-Dawley rats. Brain delivery of both CPT-Glu and Gd-DTPA was evaluated in an in situ rat brain perfusion model in the presence and absence of HAV6 peptide (1.0 mM). Gd-DTPA (0.6 mmol/kg) was intravenously (i.v.) administered with and without HAV6 peptide (0.019 mmol/kg) in rats. The detection and quantification of CPT-Glu and Gd-DTPA in the brain were carried out by LC-MS/MS and quantitative magnetic resonance imaging (MRI), respectively. Rats perfused with CPT-Glu in combination with HAV6 had significantly higher deposition of drug in the brain compared to CPT-Glu alone. MRI results also showed that administration of Gd-DTPA in the presence of HAV6 peptide led to significant accumulation of Gd-DTPA in various regions of the brain in both the in situ rat brain perfusion and in vivo studies. All observations taken together indicate that HAV6 peptide can disrupt the BBB and enhance delivery of small molecules into the brain. PMID:26705088

  9. Brain Delivery of Drug and MRI Contrast Agent: Detection and Quantitative Determination of Brain Deposition of CPT-Glu Using LC-MS/MS and Gd-DTPA Using Magnetic Resonance Imaging.

    Science.gov (United States)

    Tabanor, Kayann; Lee, Phil; Kiptoo, Paul; Choi, In-Young; Sherry, Erica B; Eagle, Cheyenne Sun; Williams, Todd D; Siahaan, Teruna J

    2016-02-01

    Successful treatment and diagnosis of neurological diseases depend on reliable delivery of molecules across the blood-brain barrier (BBB), which restricts penetration of pharmaceutical drugs and diagnostic agents into the brain. Thus, developing new noninvasive strategies to improve drug delivery across the BBB is critically needed. This study was aimed at evaluating the activity of HAV6 peptide (Ac-SHAVSS-NH2) in improving brain delivery of camptothecin-glutamate (CPT-Glu) conjugate and gadolinium-diethylenetriaminepentaacetate (Gd-DTPA) contrast agent in Sprague-Dawley rats. Brain delivery of both CPT-Glu and Gd-DTPA was evaluated in an in situ rat brain perfusion model in the presence and absence of HAV6 peptide (1.0 mM). Gd-DTPA (0.6 mmol/kg) was intravenously (iv) administered with and without HAV6 peptide (0.019 mmol/kg) in rats. The detection and quantification of CPT-Glu and Gd-DTPA in the brain were carried out by LC-MS/MS and quantitative magnetic resonance imaging (MRI), respectively. Rats perfused with CPT-Glu in combination with HAV6 had significantly higher deposition of drug in the brain compared to CPT-Glu alone. MRI results also showed that administration of Gd-DTPA in the presence of HAV6 peptide led to significant accumulation of Gd-DTPA in various regions of the brain in both the in situ rat brain perfusion and in vivo studies. All observations taken together indicate that HAV6 peptide can disrupt the BBB and enhance delivery of small molecules into the brain.

  10. Coaxial magnetic brakes using single-domain YBCO

    International Nuclear Information System (INIS)

    Putman, P.T.; Salama, K.

    2008-01-01

    In coaxial magnetic brakes, the changing field produced by movement of a solenoidal magnet induces a current in the wall of a conductive tube. The interaction of the field and current leads to a repulsive force that slows the motion of the magnet. For brake applications that require high force density, melt-textured YBCO is a clear choice of material for the magnet because it can carry high currents at a given field and temperature, and is inherently capable of operating in persistent current mode. We present calculations of the performance of this type of brake as a function of magnet current density for catch tubes composed of aluminum and titanium. These results are validated with low speed (20 m/s) tests. Calculations indicate that melt-textured magnets can decelerate projectiles with a mass of 1 kg from 2000 m/s to rest in distances on the order of 10 m. This suggests that this type of brake is suitable for use in hypervelocity experiments, which sometimes requires nondestructive deceleration of projectiles for diagnostic purposes

  11. Removal of acidic interferences in multi-pesticides residue analysis of fruits using modified magnetic nanoparticles prior to determination via ultra-HPLC-MS/MS

    International Nuclear Information System (INIS)

    Qi, Peipei; Wang, Zhiwei; Yang, Guiling; Wang, Xinquan; Shang, Chunqing; Xu, Hao; Wang, Xiangyun; Zhang, Hu; Wang, Qiang

    2015-01-01

    The authors describe magnetite (Fe 3 O 4 ) nanoparticles modified with 3-(N,N-diethylamino) propyltrimethoxysilane (Fe 3 O 4 -PSA NPs) for use as a sorbent for dispersive solid phase extraction of pesticide residues. The Fe 3 O 4 -PSA NPs were prepared by silanizing Fe 3 O 4 NPs and modifying them with 3-(N,N-diethylamino) propyltrimethoxysilane. Field-emission scanning electron microscopy, FTIR and zeta potential measurements were employed to characterize the modified NPs. They were then used as an adsorbent to remove acidic interferences (such as malic acid and succinic acid), which are major interferences in LC-MS/MS analysis in causing ion suppression in the MS spectra of pesticides. In addition, graphitized carbon black (GCB) was used as an adsorbent to eliminate interferences by pigments. The use of Fe 3 O 4 -PSA NPs can replace time-consuming centrifugation as used in the so-called QuEChERS (quick, easy, cheap, effective, rugged and safe) method. This improvement is particularly significant in high-throughput analysis. Following the optimization of the quantities of Fe 3 O 4 -PSA NPs and GCB, the method was applied to the determination of 56 pesticides in (spiked) fruits (apple, kiwi, orange and pear) by ultra-HPLC-MS/MS. The analytical ranges typically extend from 1 to 200 ng∙mL −1 , and recoveries range from 60.2 to 130 % at different concentrations of all four kinds of fruits. The LOQs for the pesticides are 10 ng∙kg −1 , which makes the method a viable tool for pesticide monitoring in fruits. (author)

  12. Definition of spontaneous reconnection

    International Nuclear Information System (INIS)

    Schindler, K.

    1984-01-01

    The author discusses his view of driven versus spontaneous. There is a close link between ''spontaneous'' and ''instability.'' One of the prominent examples for instability is the thermal convection instability. Just to remind you, if you heat a fluid layer from below, it takes a certain Rayleigh number to make it unstable. Beyond the onset point you find qualitatively new features. That is called ''spontaneous,'' and this is a bit more than semantics. It's a new qualitative property that appears and it is spontaneous although we have an energy flux through the system. It's a misconception, to call this ''driven'' pointing at the energy flux through it. Of course, the convection would not exist without this energy flux. But what makes it ''spontaneous'' is that without any particular external signal, a new qualitative feature appears. And this is what is called an ''instability'' and ''spontaneous.'' From these considerations the author got a little reassured of what distinction should be made in the field of the magnetosphere. If we have a smooth energy transport into the magnetosphere and suddenly we have this qualitatively new feature (change of B-topology) coming up; then, using this terminology we don't have a choice other than calling this spontaneous or unstable, if you like. If we ''tell'' the system where it should make its neutral line and where it should make its plasmoids, then, it is driven. And this provides a very clear-cut observational distinction. The author emphasizes the difference he sees is a qualitative difference, not only a quantitative one

  13. Experimental study of two-fluid effect during magnetic reconnection in the UTST merging experiment

    International Nuclear Information System (INIS)

    Yamasaki, Kotaro; Takemura, Koichiro; Cao, Qinghong; Watanabe, Takenori G.; Itagaki, Hirotomo; Inomoto, Michiaki; Ono, Yasushi; Kamio, Shuji; Yamada, Takuma

    2013-01-01

    Radial profile of floating potential inside the current sheet was measured for the purpose of investigating the two-fluid (Hall) effect during magnetic reconnection in the UTST merging experiment. During magnetic reconnection, the floating potential drop was formed spontaneously inside the current sheet, forming a steep electric potential gradient on its both downstream areas. Magnetic probe array measurement indicates that this potential drop appears spontaneously when the reconnection rate rapidly increase due to change in current sheet structure. The IDS probe measurement observed outflow almost equal to poloidal Alfvén speed in radial direction from the X-point, where steep gradient of floating potential is formed. This fact suggests that ion acceleration/heating is caused by the steep potential gradient formed in the downstream by magnetized electrons. (author)

  14. Ultrasound evaluation of a spontaneous plantar fascia rupture.

    Science.gov (United States)

    Louwers, Michael J; Sabb, Brian; Pangilinan, Percival H

    2010-11-01

    Plantar fascia rupture is an occasional complication in patients with chronic plantar fasciitis or in patients with plantar fasciitis treated with steroid injection. Very few cases of spontaneous plantar fascia rupture have been reported in the literature (Herrick and Herrick, Am J Sports Med 1983;11:95; Lun et al, Clin J Sports Med 1999;9:48-9; Rolf et al, J Foot Ankle Surg 1997;36:112-4; Saxena and Fullem, Am J Sports Med 2004;32:662-5). Spontaneous medial plantar fascia rupture in a 37-yr-old man with no preceding symptoms or steroid injections was confirmed with diagnostic ultrasound, which revealed severe fasciitis at the calcaneal insertion with partial tearing. After conservative treatment, the patient returned to full activities. We discuss the anatomy, risk factors, examination findings, and treatment for this condition, as well as the unique benefits that ultrasound offers over magnetic resonance imaging. It is important to consider plantar fascia rupture in patients with hindfoot pain and medioplantar ecchymosis, particularly if an injury occurred during acceleration maneuvers. Ultrasound in these cases can be used to diagnose a plantar fascia tear quickly, accurately, and cost-effectively.

  15. External influence on magnetic properties of Fe-based nanocrystalline alloys

    International Nuclear Information System (INIS)

    Sitek, Jozef; Degmova, Jarmila; Sedlackova, Katarina; Butvin, Pavol

    2006-01-01

    Amorphous and nanocrystalline ribbons of NANOPERM, FINEMET and HITPERM were studied by Moessbauer spectroscopy (MS) after the influence of external factors: different annealing atmospheres, tensile stress and several kinds of corrosion. MS is a suitable tool for such studies because the spectral parameters are very sensitive to changes in the vicinity of the probe - 57 Fe nuclei. The most sensitive parameters were hyperfine magnetic field in crystalline component, average hyperfine field in amorphous component and direction of net magnetic moments. Influence of external factors modified also the structure of the alloys, i.e. new or modified phases were identified by MS phase analysis

  16. Multivariate prediction of spontaneous repetitive responses in ventricular myocardium exposed in vitro to simulated ischemic conditions.

    Science.gov (United States)

    Schiariti, M; Puddu, P E; Rouet, R

    1994-06-01

    Guinea-pig ventricular myocardium was partly exposed to normal Tyrode's superfusion and partly to altered conditions (using modified Tyrode's solution) set to simulate acute myocardial ischemia (PO2 80 +/- 10 mmHg; no glucose; pH 7.00 +/- 0.05; K+ 12 mM). Using a double-chamber tissue bath and standard microelectrode technique, the occurrence of spontaneous repetitive responses was investigated during simulated ischemia (occlusion) and after reperfusing the previously ischemic superfused tissue with normal Tyrode's solution (reperfusion). In 62 experiments (42 animals) the effects of: (1) duration of simulated ischemia (1321 +/- 435 s), (2) stimulation rate (1002 +/- 549 ms) and (3) number of successive simulated ischemic periods (occlusions) (1.58 +/- 0.92) on: (1) resting membrane potential, (2) action potential amplitude, (3) duration of 50 and 90% action potentials and (4) maximal upstroke velocity of action potential were studied. All variables were considered as gradients (delta) between normal and ischemic tissue. Both during occlusion and upon reperfusion, spontaneous repetitive responses were coded as single, couplets, salvos (three to nine and > 10) or total spontaneous repetitive responses (coded present when at least one of the above-mentioned types was seen). The incidence of total spontaneous repetitive responses was 31% (19/62) on occlusion and 85% (53/62) upon reperfusion. Cox's models (forced and stepwise) were used to predict multivariately the occurrence of arrhythmic events considered as both total spontaneous repetitive responses and as separate entities. These models were applicable since continuous monitoring of the experiments enabled exact timing of spontaneous repetitive response onset during both occlusion and reperfusion. In predicting reperfusion spontaneous repetitive responses, total spontaneous repetitive responses and blocks observed during the occlusion period were also considered. Total occlusion spontaneous repetitive responses

  17. Spontaneous biliary peritonitis: Is bed side diagnosis possible?

    Directory of Open Access Journals (Sweden)

    Vijai Datta Upadhyaya

    2013-01-01

    Full Text Available Background: Spontaneous biliary peritonitis is a rare cause of acute abdomen. In spontaneous biliary peritonitis there is perforation in the wall of the extra-hepatic or intra-hepatic duct occurs without any traumatic or iatrogenic injury and have been described more often in neonates. The symptoms may be acute or insidious delaying the diagnosis. Present manuscript deals with diagnosis and management of these cases. Materials and Methods: This is a prospective study and all patients of suspected biliary peritonitis presented during Dec 2010 to Feb 2012 were included in the study. After preliminary investigations in all patients abdominal paracentesis was done and in cases where intra-abdominal fluid bilirubin level was several fold higher than serum bilirubin level were subjected to exploratory laparotomy. Further investigation like T-tube cholangiogram and magnetic resonance cholangiopancreatography (MRCP was done to rule out choledochal cyst before leveling these cases as SPBD. Results: A total of 6 patients were included in present series commonest presenting symptom was progressive abdominal distension without signs of overt peritonitis followed by progressive jaundice, fever and abdominal pain. On exploration site of perforation was observed in 50% of cases and in 50% of cases bile duct was not dilated. Second surgery was not required in 34% of cases. There was no mortality or significant morbidity in our series. Conclusion: Spontaneous perforation of bile duct is rare disease and high index of suspicion is required for diagnosis. Simple bed side test can help in diagnosis but T tube cholangiogram or MRCP are must to rule out choledochal cyst.

  18. Abnormal Spontaneous Neural Activity in Obsessive-Compulsive Disorder: A Resting-State Functional Magnetic Resonance Imaging Study.

    Science.gov (United States)

    Ping, Li; Su-Fang, Li; Hai-Ying, Han; Zhang-Ye, Dong; Jia, Luo; Zhi-Hua, Guo; Hong-Fang, Xiong; Yu-Feng, Zang; Zhan-Jiang, Li

    2013-01-01

    Neuroimaging studies of obsessive-compulsive disorder have found abnormalities in orbitofronto-striato-thalamic circuitry, including the orbitofrontal cortex, anterior cingulate cortex, caudate, and thalamus, but few studies have explored abnormal intrinsic or spontaneous brain activity in the resting state. We investigated both intra- and inter-regional synchronized activity in twenty patients with obsessive-compulsive disorder and 20 healthy controls using resting-state functional magnetic resonance imaging. Regional homogeneity (ReHo) and functional connectivity methods were used to analyze the intra- and inter-regional synchronized activity, respectively. Compared with healthy controls, patients with obsessive-compulsive disorder showed significantly increased ReHo in the orbitofrontal cortex, cerebellum, and insula, and decreased ReHo in the ventral anterior cingulate cortex, caudate, and inferior occipital cortex. Based on ReHo results, we determined functional connectivity differences between the orbitofrontal cortex and other brain regions in both patients with obsessive-compulsive disorder and controls. We found abnormal functional connectivity between the orbitofrontal cortex and ventral anterior cingulate cortex in patients with obsessive-compulsive disorder compared with healthy controls. Moreover, ReHo in the orbitofrontal cortex was correlated with the duration of obsessive-compulsive disorder. These findings suggest that increased intra- and inter-regional synchronized activity in the orbitofrontal cortex may have a key role in the pathology of obsessive-compulsive disorder. In addition to orbitofronto-striato-thalamic circuitry, brain regions such as the insula and cerebellum may also be involved in the pathophysiology of obsessive-compulsive disorder.

  19. A novel magnetic ionic liquid modified carbon nanotube for the simultaneous determination of aryloxyphenoxy-propionate herbicides and their metabolites in water

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Mai; Liu, Donghui; Zhao, Lu; Han, Jiajun; Liang, Yiran; Wang, Peng; Zhou, Zhiqiang, E-mail: zqzhou@cau.edu.cn

    2014-12-10

    Highlights: • A new kind of ionic liquid modified carbon nanotube has been synthesized and applied for simultaneous analysis of AOPPs and their metabolites. • The potential pollutants, such as metabolites of AOPPs, have been analyzed. • The mechanism of absorption has been discussed. • Varieties of experiment factors were optimized and selected. • This method has been successfully applied in the analysis of real water samples. - Abstract: A reliable, sensitive, rapid and environmentally friendly analysis procedure for the simultaneous determination of the analytes with a wide range of polarity in the environmental water was developed by coupling dispersive magnetic solid-phase extraction (d-MSPE) with high-performance liquid chromatography (HPLC)–diode array detector (DAD) and ultra-high pressure liquid chromatography (UHPLC)-triple quadrupole mass spectrometer (MS/MS), in this work. Magnetic ionic liquid modified multi-walled carbon nanotubes (m-IL-MWCNTs) were prepared by spontaneous assembly of magnetic nanoparticles and imidazolium-modified carbon nanotubes, and used as the sorbent of d-MSPE to simultaneously extract aryloxyphenoxy-propionate herbicides (AOPPs) and their polar acid metabolites due to the excellent π–π electron donor–acceptor interactions and anion exchange ability. The factors, including the amount of sorbent, pH of the sample solution, extraction time and the volume of elution solvent were investigated. Under the optimized conditions, the proposed d-MSPE coupling to HPLC–DAD system had a satisfactory performance, the limits of detection (LODs, defined as the signal to noise ratio of 3) and the limits of quantification (LOQs, defined as the signal to noise ratio of 10) for analytes in Milli-Q water were in the range of 2.8–14.3 and 9.8–43.2 μg L{sup −1} respectively. Calibration curves were linear (r{sup 2} > 0.998) over the concentration range from 0.02 to 1 mg L{sup −1}. The recoveries of the eight analytes ranged

  20. Collapse of ferromagnetism in itinerant-electron system: A magnetic, transport properties, and high pressure study of (Hf,Ta)Fe2 compounds

    Science.gov (United States)

    Diop, L. V. B.; Kastil, J.; Isnard, O.; Arnold, Z.; Kamarad, J.

    2014-10-01

    The magnetism and transport properties were studied for Laves (Hf,Ta)Fe2 itinerant-electron compounds, which exhibit a temperature-induced first-order transition from the ferromagnetic (FM) to the antiferromagnetic (AFM) state upon heating. At finite temperatures, the field-induced metamagnetic phase transition between the AFM and FM has considerable effects on the transport properties of these model metamagnetic compounds. A large negative magnetoresistance of about 14% is observed in accordance with the metamagnetic transition. The magnetic phase diagram is determined for the Laves Hf1-xTaxFe2 series and its Ta concentration dependence discussed. An unusual behavior is revealed in the paramagnetic state of intermediate compositions, it gives rise to the rapid increase and saturation of the local spin fluctuations of the 3d electrons. This new result is analysed in the frame of the theory of Moriya. For a chosen composition Hf0.825Ta0.175Fe2, exhibiting such remarkable features, a detailed investigation is carried out under hydrostatic pressure up to 1 GPa in order to investigate the volume effect on the magnetic properties. With increasing pressure, the magnetic transition temperature TFM-AFM from ferromagnetic to antiferromagnetic order decreases strongly non-linearly and disappears at a critical pressure of 0.75 GPa. In the pressure-induced AFM state, the field-induced first-order AFM-FM transition appears and the complex temperature dependence of the AFM-FM transition field is explained by the contribution from both the magnetic and elastic energies caused by the significant temperature variation of the amplitude of the local Fe magnetic moment. The application of an external pressure leads also to the progressive decrease of the Néel temperature TN. In addition, a large pressure effect on the spontaneous magnetization MS for pressures below 0.45 GPa, dln(Ms)/dP = -6.3 × 10-2 GPa-1 was discovered. The presented results are consistent with Moriya

  1. Magnetohydrodynamic study for three-dimensional instability of the Petschek type magnetic reconnection

    International Nuclear Information System (INIS)

    Shimizu, T.; Kondoh, K.

    2013-01-01

    The 3D instability of the spontaneous fast magnetic reconnection process is studied with magnetohydrodynamics (MHD) simulations, where the 2D model of the spontaneous fast magnetic reconnection is destabilized in three dimension. As well known in many 2D numerical MHD studies, when a 1D current sheet is destabilized with the current-driven anomalous resistivity, the 2D Petschek type fast magnetic reconnection is established. This paper shows that the 2D Petschek type fast magnetic reconnection can be destabilized in three dimension by an initial resistive disturbance which includes a weak fluctuation in the sheet current direction, i.e., along the magnetic neutral line. The resulting 3D fast magnetic reconnection finally becomes intermittent and random through a 3D instability. In addition, it is also shown that the 3D instability is suppressed by the uniform resistivity. It suggests that the 3D instability is caused in the Petschek-type reconnection process which is characterized by a strongly localized magnetic diffusion region and the slow shock acceleration of the plasma jets and is suppressed in the Sweet-Parker type reconnection process

  2. Using magnetic and chemical measurements to detect atmospherically-derived metal pollution in artificial soils and metal uptake in plants

    International Nuclear Information System (INIS)

    Sapkota, B.; Cioppa, M.T.

    2012-01-01

    Quantification of potential effects of ambient atmospheric pollution on magnetic and chemical properties of soils and plants requires precise experimental studies. A controlled growth experiment assessing magnetic and chemical parameters was conducted within (controls) and outside (exposed) a greenhouse setting. Magnetic susceptibility (MS) measurements showed that while initial MS values were similar for the sample sets, the overall MS value of exposed soil was significantly greater than in controls, suggesting an additional input of Fe-containing particles. Scanning electron microscope images of the exposed soils revealed numerous angular magnetic particles and magnetic spherules typical of vehicular exhaust and combustion processes, respectively. Similarly, chemical analysis of plant roots showed that plants grown in the exposed soil had higher concentrations of Fe and heavy (toxic) metals than controls. This evidence suggests that atmospheric deposition contributed to the MS increase in exposed soils and increased metal uptake by plants grown in this soil. - Highlights: ► Magnetic susceptibility (MS) values increased in exposed soils during the growth. ► MS values in control soils decreased from their initial values during the growth. ► Decrease in MS values due to downwards migration of Fe particles, magnetic mineral transformations and Fe uptake by plants. ► Higher metal uptake in plants grown in exposed soils than those grown in controls. ► Atmospheric particulate deposition isolated as main contributor to these effects. - Variations in atmospheric particulate levels are measurable using magnetic and chemical techniques on soils and plant biomass, and suggest pollutant levels may be higher than previously recognized.

  3. Maryland magnetic fusion research program: MS speromak

    International Nuclear Information System (INIS)

    DeSilva, A.W.; Goldenbaum, G.C.; Griem, H.R.

    1989-07-01

    The main theme of our present experimentation on MS is to prolong the spheromak lifetime. This research has been concerned with such topics as passive MHD stabilization coils, impurity control and increased energy storage. At the present time the longest lived plasmas appear to be line tied to the liner or reversal coils. The natural consequence of having net flux outside the separatrix and a resistive plasma is that the plasma shrinks in time. At some point in time the plasma is far enough from the liner, or stabilization coils, that it becomes unstable. If we increase the bias field so as to move the separatrix further inside the liner, the plasma becomes unstable earlier as the separatrix moves to a smaller radius in a shorter time than if it starts out outside the liner. We have tried to circumvent this behavior with various configurations of passive conductors used as stabilizing elements. In this paper, we detail some of the machine modifications that have been tried in attempts to produce a stable, long-lived plasma

  4. Magnetic properties of hematite nanoparticles

    DEFF Research Database (Denmark)

    Bødker, Franz; Hansen, Mikkel Fougt; Bender Koch, Christian

    2000-01-01

    The magnetic properties of hematite (alpha-Fe2O3) particles with sizes of about 16 nm have been studied by use of Mossbauer spectroscopy, magnetization measurements, and neutron diffraction. The nanoparticles are weakly ferromagnetic at temperatures at least down to 5 K with a spontaneous...... magnetization that is only slightly higher than that of weakly ferromagnetic bulk hematite. At T greater than or similar to 100 K the Mossbauer spectra contain a doublet, which is asymmetric due to magnetic relaxation in the presence of an electric field gradient in accordance with the Blume-Tjon model......, Simultaneous fitting of series of Mossbauer spectra obtained at temperatures from 5 K to well above the superparamagnetic blocking temperature allowed the estimation of the pre-exponential factor in Neel's expression for the superparamagnetic relaxation time, tau(0) = (6 +/- 4) X 10(-11) s and the magnetic...

  5. Spontaneous radiation of a chiral molecule located near a half-space of a bi-isotropic material

    Science.gov (United States)

    Guzatov, D. V.; Klimov, V. V.; Poprukailo, N. S.

    2013-04-01

    Analytical expressions for the rate of spontaneous emission from a chiral (optically active) molecule located near a half-space occupied by a chiral (bi-isotropic) material have been obtained and analyzed in detail. It is established that the rates of spontaneous emission from the "right" and "left" enantiomers of molecules occurring near the chiral medium may significantly differ in cases of chiral materials with (i) both negative dielectric permittivity and magnetic permeability (DNG metamaterial) and (ii) negative permeability and positive permittivity (MNG metamaterial). Based on this phenomenon, DMG and MNG metamaterials can be used to create devices capable of separating right and left enantiomers in racemic mixtures.

  6. Spontaneous radiation of a chiral molecule located near a half-space of a bi-isotropic material

    Energy Technology Data Exchange (ETDEWEB)

    Guzatov, D. V., E-mail: vklimov@sci.lebedev.ru [Yanka Kupala Grodno State University (Belarus); Klimov, V. V., E-mail: klimov256@gmail.com [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation); Poprukailo, N. S. [Yanka Kupala Grodno State University (Belarus)

    2013-04-15

    Analytical expressions for the rate of spontaneous emission from a chiral (optically active) molecule located near a half-space occupied by a chiral (bi-isotropic) material have been obtained and analyzed in detail. It is established that the rates of spontaneous emission from the 'right' and 'left' enantiomers of molecules occurring near the chiral medium may significantly differ in cases of chiral materials with (i) both negative dielectric permittivity and magnetic permeability (DNG metamaterial) and (ii) negative permeability and positive permittivity (MNG metamaterial). Based on this phenomenon, DMG and MNG metamaterials can be used to create devices capable of separating right and left enantiomers in racemic mixtures.

  7. Spontaneous radiation of a chiral molecule located near a half-space of a bi-isotropic material

    International Nuclear Information System (INIS)

    Guzatov, D. V.; Klimov, V. V.; Poprukailo, N. S.

    2013-01-01

    Analytical expressions for the rate of spontaneous emission from a chiral (optically active) molecule located near a half-space occupied by a chiral (bi-isotropic) material have been obtained and analyzed in detail. It is established that the rates of spontaneous emission from the “right” and “left” enantiomers of molecules occurring near the chiral medium may significantly differ in cases of chiral materials with (i) both negative dielectric permittivity and magnetic permeability (DNG metamaterial) and (ii) negative permeability and positive permittivity (MNG metamaterial). Based on this phenomenon, DMG and MNG metamaterials can be used to create devices capable of separating right and left enantiomers in racemic mixtures.

  8. Field Induced Magnetic Moments in a Metastable Iron-Mercury Alloy

    DEFF Research Database (Denmark)

    Pedersen, M.S.; Mørup, Steen; Linderoth, Søren

    1996-01-01

    The magnetic properties of a metastable iron-mercury alloy have been investigated in the temperature range from 5 to 200 K by Mossbauer spectroscopy and magnetization measurements. At low temperature the magnetic moment per iron atom is larger than af alpha-Fe. The effective spontaneous magnetic ....... It was found that the field-induced increase of the magnetic moment in the metastable iron-mecury alloy was about 0.06 Bohr magnetons per iron atom in the temperature range from 5 to 200 K for a field change from 6 to 12 T....

  9. Characterization of magnetically enhanced buried soil layer in arid environment

    Science.gov (United States)

    Petrovsky, E.; Grison, H.; Kapicka, A.; Silva, P. F.; Font, E.

    2011-12-01

    Magnetic susceptibility (MS) of soils, reflecting the presence of magnetite/maghemite, can be used in several environmental applications. Magnetic topsoil mapping is often used to outline areas polluted by atmospherically deposited dust. However, in these studies, the magnetically enhanced layer is usually shallow, some 5-6 cm under the surface. In our contribution, we present the case when the magnetic susceptibility is enhanced in deeper soil layers. Investigated soils are mostly sandy soils, from several localities in Portugal, in a zone with arid climate. Sample profiles were collected always in forests or forest stands with pines, cork oaks or eucalyptus trees in two areas: around the city of Sines (on the coast south of Lisbon) and around the city of Abrantes (inland, north-east of Lisbon). Both areas are presumably affected by one major source of pollution - power plant. Surface magnetic susceptibility measurements were performed by Bartington MS2D loop; values vary from 10 to 300 x 10-5 SI units. Vertical distribution of magnetic susceptibility was measured already in situ using the SM400 (ZHInstruments) on profiles about 40cm in length. Mass-specific MS was determined using Bartington MS2B dual frequency meter and Agico MFK1. Nine vertical profiles were selected for detailed analyses including the ARM, IRM and hysteresis measurements. Distinctly enhanced magnetic layers were detected in deeper horizons. This enhancement can be ascribed to several mechanisms. Migration of magnetic particles seems to be probable, as observed in our model experiments with sand columns. In coastal areas, the enhanced layer could be due to tsunami deposits, as described in other areas. Finally, in particular at sites close to power plants, the construction works followed by surface remediation have to be also considered as one of the possible mechanisms.

  10. Early MR abnormality indicating functional recovery from spontaneous intracerebral hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Fumeya, Hiroshi; Hideshima, Hiroshi [Hideshima Hospital, Musashino, Tokyo (Japan)

    1991-10-01

    Magnetic resonance (MR) imaging as an indicator of recovery from hemiparesis was evaluated in 60 patients with spontaneous intracerebral hemorrhage. T{sub 2}-weighted MR images revealed early MR abnormality (EMA) of the corticospinal tract within 1 week of ictus. Most patients without EMA recovered beyond Brunnstrom's Recovery Stage 3 while only a few patients with EMA did so. Patients with EMA cannot regain motor function because EMA is almost always followed by complete tract degeneration. EMA in the brainstem and poor motor function recovery are closely correlated. (author).

  11. Early MR abnormality indicating functional recovery from spontaneous intracerebral hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Fumeya, Hiroshi; Hideshima, Hiroshi (Hideshima Hospital, Musashino, Tokyo (Japan))

    1991-10-01

    Magnetic resonance (MR) imaging as an indicator of recovery from hemiparesis was evaluated in 60 patients with spontaneous intracerebral hemorrhage. T{sub 2}-weighted MR images revealed early MR abnormality (EMA) of the corticospinal tract within 1 week of ictus. Most patients without EMA recovered beyond Brunnstrom's Recovery Stage 3 while only a few patients with EMA did so. Patients with EMA cannot regain motor function because EMA is almost always followed by complete tract degeneration. EMA in the brainstem and poor motor function recovery are closely correlated. (author).

  12. A superconducting magnet: Tb2Mo3Si4

    International Nuclear Information System (INIS)

    Aliev, F.G.; Pryadun, V.V.; Vieira, S.; Villar, R.; Paredes, J.; Levanyuk, A.P.; Yarovets, V.I.

    1994-01-01

    Measurements of transport properties (resistivity, Seebeck coefficient, thermal conductivity), thermal expansion, heat capacity and magnetic susceptibility of Tb 2 Mo 3 Si 4 samples with different annealing conditions show that in this superconductor (with T c between 0.5 and 1.2 K) a complex magnetic structure exists in the normal state, characterized by transitions at 2.3 K and 19 K. The expected magnetic structures are discussed taking into account the absence of experimental evidence of spontaneous magnetization and the possibility of an antiferromagnetic-structure formation without change of translational geometry. (orig.)

  13. Dansyl-peptides matrix-assisted laser desorption/ionization mass spectrometric (MALDI-MS) and tandem mass spectrometric (MS/MS) features improve the liquid chromatography/MALDI-MS/MS analysis of the proteome.

    Science.gov (United States)

    Chiappetta, Giovanni; Ndiaye, Sega; Demey, Emmanuelle; Haddad, Iman; Marino, Gennaro; Amoresano, Angela; Vinh, Joëlle

    2010-10-30

    Peptide tagging is a useful tool to improve matrix-assisted laser desorption/ionization tandem mass spectrometric (MALDI-MS/MS) analysis. We present a new application of the use of the dansyl chloride (DNS-Cl). DNS-Cl is a specific primary amine reagent widely used in protein biochemistry. It adds a fluorescent dimethylaminonaphthalene moiety to the molecule. The evaluation of MALDI-MS and MS/MS analyses of dansylated peptides shows that dansylation raises the ionization efficiency of the most hydrophilic species compared with the most hydrophobic ones. Consequently, higher Mascot scores and protein sequence coverage are obtained by combining MS and MS/MS data of native and tagged samples. The N-terminal DNS-Cl sulfonation improves the peptide fragmentation and promotes the generation of b-fragments allowing better peptide sequencing. In addition, we set up a labeling protocol based on the microwave chemistry. Peptide dansylation proved to be a rapid and cheap method to improve the performance of liquid chromatography (LC)/MALDI-MS/MS analysis at the proteomic scale in terms of peptide detection and sequence coverage. Copyright © 2010 John Wiley & Sons, Ltd.

  14. Short Straight Sections in the LHC Matching Sections (MS SSS) An Extension of the Arc Cryostats to Fulfil Specific Machine Functionalities

    CERN Document Server

    Parma, V; Lutton, F

    2005-01-01

    The LHC insertions require 50 specific superconducting quadrupoles in the matching sections, operating either in 1.9 K superfluid helium or in boiling helium at 4.5 K. These magnets are assembled together with corrector magnets in cold masses, and are inserted in individual cryostats to form the MS Short Straight Sections (MS SSS). The variety of quadrupoles and corrector magnets leads to 10 families of cold masses, with lengths ranging from 5 to 12 m and weights ranging from 60 to 140 kN. The MS SSS need to fulfil specific requirements related to the collider topology, its cryogenic layout and the powering scheme. Most MS SSS are standalone cryogenic and super-conducting units, i.e. they are not in the continuous arc cryostat, and therefore need dedicated cryogenic and electrical feeding. Specially designed cryostat end-caps are required to close the vacuum vessels at each end, which include low heat in-leak Cold-to-Warm transitions (CWT) for the beam tubes and 6 kA local electrical feedthrough for powering...

  15. Magnetic Parameter Changes in Soil and Sediments in the Presence of Hydrocarbon Contamination

    Science.gov (United States)

    Appel, E.; Porsch, K.; Rijal, M. L.; Ameen, N. N.; Kappler, A.

    2014-12-01

    Magnetic proxies were successfully used for fast and non-destructive detection of fly ash related heavy metal pollution. Correlations of magnetic signals with organic contaminants in soils and sediments were also reported; however, their significance is unclear because of co-existing heavy metal pollution. At a hydrocarbon (HC) contaminated former military airbase (Hradcany, Czech Rep.), where heavy metal contents are insignificant, we detected clearly higher magnetic concentrations at the top of the groundwater fluctuation (GWF) zone. Frequent GWF by up to ca. one meter was caused through remediation by air sparging. In this study and all previous ones magnetite was identified as the dominant phase for higher magnetic concentrations. To determine the importance of microbial activity and soil parameters on changes in magnetic susceptibility (MS) laboratory batch experiments with different microbially active and sterile soils without carbon addition and with gasoline amendment were setup. MS of these microcosms was followed weekly. Depending on the soil MS either increased or decreased by up to ~7% and remained constant afterwards. The main findings were that MS changes were mainly microbially driven and influenced by the bioavailable Fe content, the initial MS and the organic carbon content of the soils. Moreover, we tested magnetic changes in laboratory columns, filled with sand from the field site Hradcany, by simulating water level changes. The observed changes were small and hardly statistically significant. Our laboratory studies revealed that different factors influence changes in magnetic properties of soil/sediments after HC contamination, with much smaller effects than expected from anomalies observed at field sites. With the present results, the ambitious goal of using magnetic monitoring for detecting HC contaminations by oil spills seem far from practical application.

  16. Effect of exercise training on Ca2+ release units of left ventricular myocytes of spontaneously hypertensive rats.

    Science.gov (United States)

    Carneiro-Júnior, M A; Quintão-Júnior, J F; Drummond, L R; Lavorato, V N; Drummond, F R; Amadeu, M A; Oliveira, E M; Felix, L B; Cruz, J S; Mill, J G; Natali, A J; Prímola-Gomes, T N

    2014-08-29

    In cardiomyocytes, calcium (Ca2+) release units comprise clusters of intracellular Ca2+ release channels located on the sarcoplasmic reticulum, and hypertension is well established as a cause of defects in calcium release unit function. Our objective was to determine whether endurance exercise training could attenuate the deleterious effects of hypertension on calcium release unit components and Ca2+ sparks in left ventricular myocytes of spontaneously hypertensive rats. Male Wistar and spontaneously hypertensive rats (4 months of age) were divided into 4 groups: normotensive (NC) and hypertensive control (HC), and normotensive (NT) and hypertensive trained (HT) animals (7 rats per group). NC and HC rats were submitted to a low-intensity treadmill running protocol (5 days/week, 1 h/day, 0% grade, and 50-60% of maximal running speed) for 8 weeks. Gene expression of the ryanodine receptor type 2 (RyR2) and FK506 binding protein (FKBP12.6) increased (270%) and decreased (88%), respectively, in HC compared to NC rats. Endurance exercise training reversed these changes by reducing RyR2 (230%) and normalizing FKBP12.6 gene expression (112%). Hypertension also increased the frequency of Ca2+ sparks (HC=7.61±0.26 vs NC=4.79±0.19 per 100 µm/s) and decreased its amplitude (HC=0.260±0.08 vs NC=0.324±0.10 ΔF/F0), full width at half-maximum amplitude (HC=1.05±0.08 vs NC=1.26±0.01 µm), total duration (HC=11.51±0.12 vs NC=14.97±0.24 ms), time to peak (HC=4.84±0.06 vs NC=6.31±0.14 ms), and time constant of decay (HC=8.68±0.12 vs NC=10.21±0.22 ms). These changes were partially reversed in HT rats (frequency of Ca2+ sparks=6.26±0.19 µm/s, amplitude=0.282±0.10 ΔF/F0, full width at half-maximum amplitude=1.14±0.01 µm, total duration=13.34±0.17 ms, time to peak=5.43±0.08 ms, and time constant of decay=9.43±0.15 ms). Endurance exercise training attenuated the deleterious effects of hypertension on calcium release units of left ventricular myocytes.

  17. Effect of exercise training on Ca2+ release units of left ventricular myocytes of spontaneously hypertensive rats

    Directory of Open Access Journals (Sweden)

    M.A. Carneiro-Júnior

    2014-11-01

    Full Text Available In cardiomyocytes, calcium (Ca2+ release units comprise clusters of intracellular Ca2+ release channels located on the sarcoplasmic reticulum, and hypertension is well established as a cause of defects in calcium release unit function. Our objective was to determine whether endurance exercise training could attenuate the deleterious effects of hypertension on calcium release unit components and Ca2+ sparks in left ventricular myocytes of spontaneously hypertensive rats. Male Wistar and spontaneously hypertensive rats (4 months of age were divided into 4 groups: normotensive (NC and hypertensive control (HC, and normotensive (NT and hypertensive trained (HT animals (7 rats per group. NC and HC rats were submitted to a low-intensity treadmill running protocol (5 days/week, 1 h/day, 0% grade, and 50-60% of maximal running speed for 8 weeks. Gene expression of the ryanodine receptor type 2 (RyR2 and FK506 binding protein (FKBP12.6 increased (270% and decreased (88%, respectively, in HC compared to NC rats. Endurance exercise training reversed these changes by reducing RyR2 (230% and normalizing FKBP12.6 gene expression (112%. Hypertension also increased the frequency of Ca2+ sparks (HC=7.61±0.26 vs NC=4.79±0.19 per 100 µm/s and decreased its amplitude (HC=0.260±0.08 vs NC=0.324±0.10 ΔF/F0, full width at half-maximum amplitude (HC=1.05±0.08 vs NC=1.26±0.01 µm, total duration (HC=11.51±0.12 vs NC=14.97±0.24 ms, time to peak (HC=4.84±0.06 vs NC=6.31±0.14 ms, and time constant of decay (HC=8.68±0.12 vs NC=10.21±0.22 ms. These changes were partially reversed in HT rats (frequency of Ca2+ sparks=6.26±0.19 µm/s, amplitude=0.282±0.10 ΔF/F0, full width at half-maximum amplitude=1.14±0.01 µm, total duration=13.34±0.17 ms, time to peak=5.43±0.08 ms, and time constant of decay=9.43±0.15 ms. Endurance exercise training attenuated the deleterious effects of hypertension on calcium release units of left ventricular myocytes.

  18. Effect of exercise training on Ca2+ release units of left ventricular myocytes of spontaneously hypertensive rats

    International Nuclear Information System (INIS)

    Carneiro-Júnior, M.A.; Quintão-Júnior, J.F.; Drummond, L.R.; Lavorato, V.N.; Drummond, F.R.; Amadeu, M.A.; Oliveira, E.M.; Felix, L.B.; Cruz, J.S.; Mill, J.G.; Natali, A.J.; Prímola-Gomes, T.N.

    2014-01-01

    In cardiomyocytes, calcium (Ca 2+ ) release units comprise clusters of intracellular Ca 2+ release channels located on the sarcoplasmic reticulum, and hypertension is well established as a cause of defects in calcium release unit function. Our objective was to determine whether endurance exercise training could attenuate the deleterious effects of hypertension on calcium release unit components and Ca 2+ sparks in left ventricular myocytes of spontaneously hypertensive rats. Male Wistar and spontaneously hypertensive rats (4 months of age) were divided into 4 groups: normotensive (NC) and hypertensive control (HC), and normotensive (NT) and hypertensive trained (HT) animals (7 rats per group). NC and HC rats were submitted to a low-intensity treadmill running protocol (5 days/week, 1 h/day, 0% grade, and 50-60% of maximal running speed) for 8 weeks. Gene expression of the ryanodine receptor type 2 (RyR2) and FK506 binding protein (FKBP12.6) increased (270%) and decreased (88%), respectively, in HC compared to NC rats. Endurance exercise training reversed these changes by reducing RyR2 (230%) and normalizing FKBP12.6 gene expression (112%). Hypertension also increased the frequency of Ca 2+ sparks (HC=7.61±0.26 vs NC=4.79±0.19 per 100 µm/s) and decreased its amplitude (HC=0.260±0.08 vs NC=0.324±0.10 ΔF/F 0 ), full width at half-maximum amplitude (HC=1.05±0.08 vs NC=1.26±0.01 µm), total duration (HC=11.51±0.12 vs NC=14.97±0.24 ms), time to peak (HC=4.84±0.06 vs NC=6.31±0.14 ms), and time constant of decay (HC=8.68±0.12 vs NC=10.21±0.22 ms). These changes were partially reversed in HT rats (frequency of Ca 2+ sparks=6.26±0.19 µm/s, amplitude=0.282±0.10 ΔF/F 0 , full width at half-maximum amplitude=1.14±0.01 µm, total duration=13.34±0.17 ms, time to peak=5.43±0.08 ms, and time constant of decay=9.43±0.15 ms). Endurance exercise training attenuated the deleterious effects of hypertension on calcium release units of left ventricular myocytes

  19. Micromagnetics of rare-earth efficient permanent magnets

    Science.gov (United States)

    Fischbacher, Johann; Kovacs, Alexander; Gusenbauer, Markus; Oezelt, Harald; Exl, Lukas; Bance, Simon; Schrefl, Thomas

    2018-05-01

    The development of permanent magnets containing less or no rare-earth elements is linked to profound knowledge of the coercivity mechanism. Prerequisites for a promising permanent magnet material are a high spontaneous magnetization and a sufficiently high magnetic anisotropy. In addition to the intrinsic magnetic properties the microstructure of the magnet plays a significant role in establishing coercivity. The influence of the microstructure on coercivity, remanence, and energy density product can be understood by using micromagnetic simulations. With advances in computer hardware and numerical methods, hysteresis curves of magnets can be computed quickly so that the simulations can readily provide guidance for the development of permanent magnets. The potential of rare-earth reduced and rare-earth free permanent magnets is investigated using micromagnetic simulations. The results show excellent hard magnetic properties can be achieved in grain boundary engineered NdFeB, rare-earth magnets with a ThMn12 structure, Co-based nano-wires, and L10-FeNi provided that the magnet’s microstructure is optimized.

  20. The relationship between MRI and PET changes and cognitive disturbances in MS

    DEFF Research Database (Denmark)

    Sørensen, Per Soelberg; Jønsson, Agnete; Kahr Mathiesen, Henrik

    2006-01-01

    Cognitive dysfunction in multiple sclerosis (MS) is present in approximately 50% of the patients. Only moderate correlations have been found between cognitive dysfunction and T2 lesion load, black holes or atrophy. Cognitive dysfunction in MS is probably related to the overall disease burden...... of the brain including abnormalities in normal appearing white matter (NAWM) and cortical grey matter, which is undetected with conventional magnetic resonance imaging (MRI). Hence, imaging techniques that embrace such abnormalities are needed to achieve better correlation with cognitive dysfunction. MR...

  1. Response of dairy cattle to transient voltages and magnetic fields

    International Nuclear Information System (INIS)

    Reinemann, D.J.; Laughlin, N.K.; Stetson, L.E.

    1995-01-01

    Stray voltages in dairy facilities have been studied since the 1970's. Previous research using steady-state ac and dc voltages has defined cow-contact voltage levels which may cause behavior and associated production problems. This research was designed to address concerns over possible effects of transient voltages and magnetic fields on dairy cows. Dairy cows response to transient voltages and magnetic fields was measured. The waveforms of the transient voltages applied were: 5 cycles of 60-Hz ac with a total pulse time of 83 ms, 1 cycle of 60-Hz ac with a total pulse time of 16 ms, and 1 cycle of an ac square wave (spiking positive and negative) of 2-ms duration. Alternating magnetic fields were produced by passing 60-Hz ac fundamental frequency with 2nd and 3rd harmonic and random noise components in metal structures around the cows. The maximum magnetic field associated with this current flow was in excess of 4 G. A wide range of sensitivity to transient voltages was observed among cows. Response levels from 24 cows to each transient exposure were normally distributed. No responses to magnetic fields were observed

  2. Observation of new spontaneous fission activities from elements 100 to 105

    International Nuclear Information System (INIS)

    Somerville, L.P.

    1982-03-01

    Several new Spontaneous Fission (SF) activities have been found. No definite identification could be made for any of the new SF activities; however, half-lives and possible assignments to element-104 isotopes consistent with several cross bombardments include 257 Rf(3.8 s, 14% SF), 258 Rf(13 ms), 259 Rf(approx. 3 s, 8% SF), 260 Rf(approx. 20 ms), and 262 Rf(approx. 50 ms). The 80-ms SF activity claimed by the Dubna group for the discovery of element 104 ( 260 104) was not observed. A difficulty exists in the interpretation that 260 Rf is a approx. 20-ms SF activity: in order to be correct, for example, the SF activities with half-lives between 14 and 24 ms produced in the reactions 109- to 119-MeV 18 O + 248 Cm, 88- to 100-MeV 15 N + 249 Bk, and 96-MeV 18 O + 249 Cf must be other nuclides due to their large production cross sections, or the cross sections for production of 260 Rf must be enhanced by unknown mechanisms. Based on calculated total production cross sections a possible approx. 1% electron-capture branch in 258 Lr(4.5 s) to the SF emitter 258 No(1.2 ms) and an upper limit of 0.05% for SF branching in 254 No(55 s) were determined. Other measured half-lives from unknown nuclides produced in respective reactions include approx. 1.6 s ( 18 O + 248 CM), indications of a approx. 47-s SF activity (75-MeV 12 C + 249 Cf), and two or more SF activities with 3 s less than or equal to T/sub 1/2/ less than or equal to 60 s ( 18 O + 249 Bk). The most exciting conclusion of this work is that if the tentative assignments to even-even element 104 isotopes are correct, there would be a sudden change in the SF half-life systematics at element 104 which has been predicted theoretically and attributed to the disappearance of the second hump of the double-humped fission barrier

  3. Spontaneous breaking of N=2 to N=1 in rigid and local supersymmetric theories

    CERN Document Server

    Ferrara, Sergio; Porrati, Massimo

    1996-01-01

    We analyze the relation between rigid and local supersymmetric N=2 field theories, when half of the supersymmetries are spontaneously broken. In particular, we show that the recently found partial supersymmety breaking induced by electric and magnetic Fayet-Iliopoulos terms in rigid theories can be obtained by a suitable flat limit of previously constructed N=2 supergravity models with partial super-Higgs in the observable sector.

  4. Magnetic Signature of Glacial Flour in Sediments From Bear Lake, Utah/Idaho

    Science.gov (United States)

    Rosenbaum, J. G.; Dean, W. E.; Colman, S. M.; Reynolds, R. L.

    2002-12-01

    Variations in magnetic properties within an interval of Bear Lake sediments correlative with oxygen isotope stage 2 (OIS 2) and OIS 3 provide a record of glacial flour production for the Uinta Mountains. Like sediments of the same age from Upper Klamath Lake (OR), these Bear Lake sediments have high magnetic susceptibilities (MS) relative to non-glacial-age sediments and contain well-defined millennial-scale variations in magnetic properties. In contrast to glacial flour derived from volcanic rocks surrounding Upper Klamath Lake, glacial flour derived from the Uinta Mountains and deposited in Bear Lake by the Bear River has low magnetite content but high hematite content. The relatively low MS values of younger and older non-glacial-age sediments are due entirely to dilution by non-magnetic endogenic carbonate and to the effects of sulfidic alteration of detrital Fe-oxides. Analysis of samples from streams entering Bear Lake and from along the course of the Bear River demonstrates that, in comparison to other areas of the catchment, sediment derived from the Uinta Mountains is rich in hematite (high HIRM) and aluminum, and poor in magnetite (low MS) and titanium. Within the glacial-age lake sediments, there are strong positive correlations among HIRM, Al/Ti, and fine sediment grain size. MS varies inversely with theses three variables. These relations indicate that the observed millennial-scale variations in magnetic and chemical properties arise from varying proportions of two detrital components: (1) very fine-grained glacial flour derived from Proterozoic metasedimentary rocks in the Uinta Mountains and characterized by high HIRM and low MS, and (2) somewhat coarser material, characterized by higher MS and lower HIRM, derived from widespread sedimentary rocks along the course of the Bear River and around Bear Lake. Measurement of glacial flour incorporated in lake sediments can provide a continuous history of alpine glaciation, because the rate of accumulation

  5. Explicit and spontaneous retrieval of emotional scenes: Electrophysiological correlates

    Science.gov (United States)

    Weymar, Mathias; Bradley, Margaret M.; El-Hinnawi, Nasryn; Lang, Peter J.

    2014-01-01

    When event-related potentials are measured during a recognition task, items that have previously been presented typically elicit a larger late (400–800 ms) positive potential than new items. Recent data, however, suggest that emotional, but not neutral, pictures show ERP evidence of spontaneous retrieval when presented in a free-viewing task (Ferrari, Bradley, Codispoti & Lang, 2012). In two experiments, we further investigated the brain dynamics of implicit and explicit retrieval. In Experiment 1, brain potentials were measured during a semantic categorization task, which did not explicitly probe episodic memory, but which, like a recognition task, required an active decision and a button press, and were compared to those elicited during recognition and free viewing. Explicit recognition prompted a late enhanced positivity for previously presented, compared to new, pictures regardless of hedonic content. In contrast, only emotional pictures showed an old-new difference when the task did not explicitly probe episodic memory, either when either making an active categorization decision regarding picture content, or when simply viewing pictures. In Experiment 2, however, neutral pictures did prompt a significant old-new ERP difference during subsequent free viewing when emotionally arousing pictures were not included in the encoding set. These data suggest that spontaneous retrieval is heightened for salient cues, perhaps reflecting heightened attention and elaborative processing at encoding. PMID:23795588

  6. MALDI-TOF MS/MS measurements of PMMA

    NARCIS (Netherlands)

    Becer, C.R.; Baumgaertel, A.; Gottschaldt, M.; Schubert, U.S.

    2008-01-01

    The polymer poly(Me methacrylate) (PMMA) was analyzed using the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) technique. The MALDI-TOF MS app. was coupled with a collision-induced dissocn. (CID) unit. The performance of the MALDI-TOF/TOF MS method in

  7. External influence on magnetic properties of Fe-based nanocrystalline alloys

    Energy Technology Data Exchange (ETDEWEB)

    Sitek, Jozef [Department of Nuclear Physics and Technology, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 812 19 Bratislava (Slovakia)]. E-mail: jozef.sitek@stuba.sk; Degmova, Jarmila [Department of Nuclear Physics and Technology, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 812 19 Bratislava (Slovakia); Sedlackova, Katarina [Department of Nuclear Physics and Technology, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovicova 3, 812 19 Bratislava (Slovakia); Butvin, Pavol [Institute of Physics, Slovak Academy of Sciences, Dubravska cesta 9, 845 11 Bratislava (Slovakia)

    2006-09-15

    Amorphous and nanocrystalline ribbons of NANOPERM, FINEMET and HITPERM were studied by Moessbauer spectroscopy (MS) after the influence of external factors: different annealing atmospheres, tensile stress and several kinds of corrosion. MS is a suitable tool for such studies because the spectral parameters are very sensitive to changes in the vicinity of the probe -{sup 57}Fe nuclei. The most sensitive parameters were hyperfine magnetic field in crystalline component, average hyperfine field in amorphous component and direction of net magnetic moments. Influence of external factors modified also the structure of the alloys, i.e. new or modified phases were identified by MS phase analysis.

  8. The multiple sclerosis visual pathway cohort: understanding neurodegeneration in MS.

    Science.gov (United States)

    Martínez-Lapiscina, Elena H; Fraga-Pumar, Elena; Gabilondo, Iñigo; Martínez-Heras, Eloy; Torres-Torres, Ruben; Ortiz-Pérez, Santiago; Llufriu, Sara; Tercero, Ana; Andorra, Magi; Roca, Marc Figueras; Lampert, Erika; Zubizarreta, Irati; Saiz, Albert; Sanchez-Dalmau, Bernardo; Villoslada, Pablo

    2014-12-15

    Multiple Sclerosis (MS) is an immune-mediated disease of the Central Nervous System with two major underlying etiopathogenic processes: inflammation and neurodegeneration. The latter determines the prognosis of this disease. MS is the main cause of non-traumatic disability in middle-aged populations. The MS-VisualPath Cohort was set up to study the neurodegenerative component of MS using advanced imaging techniques by focusing on analysis of the visual pathway in a middle-aged MS population in Barcelona, Spain. We started the recruitment of patients in the early phase of MS in 2010 and it remains permanently open. All patients undergo a complete neurological and ophthalmological examination including measurements of physical and disability (Expanded Disability Status Scale; Multiple Sclerosis Functional Composite and neuropsychological tests), disease activity (relapses) and visual function testing (visual acuity, color vision and visual field). The MS-VisualPath protocol also assesses the presence of anxiety and depressive symptoms (Hospital Anxiety and Depression Scale), general quality of life (SF-36) and visual quality of life (25-Item National Eye Institute Visual Function Questionnaire with the 10-Item Neuro-Ophthalmic Supplement). In addition, the imaging protocol includes both retinal (Optical Coherence Tomography and Wide-Field Fundus Imaging) and brain imaging (Magnetic Resonance Imaging). Finally, multifocal Visual Evoked Potentials are used to perform neurophysiological assessment of the visual pathway. The analysis of the visual pathway with advance imaging and electrophysilogical tools in parallel with clinical information will provide significant and new knowledge regarding neurodegeneration in MS and provide new clinical and imaging biomarkers to help monitor disease progression in these patients.

  9. [Spontaneous bacterial peritonitis].

    Science.gov (United States)

    Velkey, Bálint; Vitális, Eszter; Vitális, Zsuzsanna

    2017-01-01

    Spontaneous bacterial peritonitis occurs most commonly in cirrhotic patients with ascites. Pathogens get into the circulation by intestinal translocation and colonize in peritoneal fluid. Diagnosis of spontaneous bacterial peritonitis is based on elevated polymorphonuclear leukocyte count in the ascites (>0,25 G/L). Ascites culture is often negative but aids to get information about antibiotic sensitivity in positive cases. Treatment in stable patient can be intravenous then orally administrated ciprofloxacin or amoxicillin/clavulanic acid, while in severe cases intravenous III. generation cephalosporin. Nosocomial spontaneous bacterial peritonitis often caused by Gram-positive bacteria and multi-resistant pathogens can also be expected thus carbapenem should be the choice of the empiric treatment. Antibiotic prophylaxis should be considered. Norfloxacin is used most commonly, but changes are expected due to increase in quinolone resistance. As a primary prophylaxis, a short-term antibiotic treatment is recommended after gastrointestinal bleeding for 5 days, while long-term prophylaxis is for patients with low ascites protein, and advanced disease (400 mg/day). Secondary prophylaxis is recommended for all patients recovered from spontaneous bacterial peritonitis. Due to increasing antibiotic use of antibiotics prophylaxis is debated to some degree. Orv. Hetil., 2017, 158(2), 50-57.

  10. MR demonstration of spontaneous acute epidural hematoma of the thoracic spine

    International Nuclear Information System (INIS)

    Avrahami, E.; Tadmor, R.; Feibel, M.; Itzhak, Y.; Tel Aviv Univ.; Ram, Z.; Tel Aviv Univ.

    1989-01-01

    Two patients with spontaneous epidural hematoma of the thoracic spine are presented. The magnetic resonance (MR) examination performed within the first hours following the onset of symptoms demonstrated an epidural elongated lesion impinging on the spinal cord, compatible with hematoma. In one of the patients this finding was surgically confirmed. The second patient improved under steroid treatment. The MR findings were highly suggestive of the pathological nature of the lesion. The MR examination should replace other diagnostic procedures, such as computerised tomography (CT) and myelography. (orig.)

  11. In Situ Magnetic Susceptibility Variations at Two Contaminated Sites: Brandywine, MD and Bemidji, MN

    Science.gov (United States)

    Donaldson, Y. Y.; Kessouri, P.; Ntarlagiannis, D.; Johnson, T. C.; Day-Lewis, F. D.; Johnson, C. D.; Bekins, B. A.; Slater, L. D.

    2017-12-01

    Geophysical methods are widely used monitoring tools for investigating subsurface processes. Compared to more traditional methods, they are low cost and minimally invasive. Magnetic susceptibility (MS) is a geophysical technique particularly sensitive to the presence of ferri/ ferro-magnetic particles such as iron oxides (e.g., magnetite, hematite and goethite). These oxides can be formed through microbially mediated redox reactions, inducing changes in the soil properties that can be observed by MS measurements. Monitoring MS changes over time provides indications of iron mineral transformations in the ground. These transformations are of particular interest for the characterization of contaminated sites. We acquired borehole MS measurements from two contaminated sites: Brandywine, MD and Bemidji, MN. Active remediation was applied at Brandywine, whereas natural attenuation has been geophysically monitored at Bemidji since 2011 using MS log measurements. High MS values were observed at both sites within the contaminated area only. We hypothesize that this is due to iron reducing bacteria reducing Fe-(III) to Fe-(II) and utilizing contaminants and/or amendments injected as a carbon source. At Bemidji, elevated MS readings were observed in the smear zone and correlate to the presence of magnetite. Furthermore, time-lapse MS observations at Bemidji indicate a decay in signal amplitude over time suggesting further redox transformation into less magnetic particles. For both field examples presented here, we observe variations in magnetic susceptibility within the contaminated areas that can be linked with redox reactions and mineral transformations occurring during the degradation of organic contaminants.

  12. Non-equilibrium magnetic colloidal dispersions at liquid-air interfaces: dynamic patterns, magnetic order and self-assembled swimmers

    International Nuclear Information System (INIS)

    Snezhko, Alexey

    2011-01-01

    Colloidal dispersions of interacting particles subjected to an external periodic forcing often develop nontrivial self-assembled patterns and complex collective behavior. A fundamental issue is how collective ordering in such non-equilibrium systems arises from the dynamics of discrete interacting components. In addition, from a practical viewpoint, by working in regimes far from equilibrium new self-organized structures which are generally not available through equilibrium thermodynamics can be created. In this review spontaneous self-assembly phenomena in magnetic colloidal dispersions suspended at liquid-air interfaces and driven out of equilibrium by an alternating magnetic field are presented. Experiments reveal a new type of nontrivially ordered self-assembled structures emerging in such systems in a certain range of excitation parameters. These dynamic structures emerge as a result of the competition between magnetic and hydrodynamic forces and have complex unconventional magnetic ordering. Nontrivial self-induced hydrodynamic fields accompany each out-of-equilibrium pattern. Spontaneous symmetry breaking of the self-induced surface flows leading to a formation of self-propelled microstructures has been discovered. Some features of the self-localized structures can be understood in the framework of the amplitude equation (Ginzburg-Landau type equation) for parametric waves coupled to the conservation law equation describing the evolution of the magnetic particle density and the Navier-Stokes equation for hydrodynamic flows. To understand the fundamental microscopic mechanisms governing self-assembly processes in magnetic colloidal dispersions at liquid-air interfaces a first-principle model for a non-equilibrium self-assembly is presented. The latter model allows us to capture in detail the entire process of out-of-equilibrium self-assembly in the system and reproduces most of the observed phenomenology. (topical review)

  13. Spontaneous Intracranial Hypotension Treated with a Targeted CT-Guided Epidural Blood Patch

    Directory of Open Access Journals (Sweden)

    Inês Correia

    2016-01-01

    Full Text Available Spontaneous intracranial hypotension (SIH is an important cause of new daily persistent headache. It is thought to be due to spontaneous spinal cerebrospinal fluid (CSF leaks, which probably have a multifactorial etiology. The classic manifestation of SIH is an orthostatic headache, but other neurological symptoms may be present. An epidural blood patch is thought to be the most effective treatment, but a blind infusion may be ineffective. We describe the case of a young man who developed an acute severe headache, with pain worsening when assuming an upright posture and relief gained with recumbency. No history of previous headache, recent cranial or cervical trauma, or invasive procedures was reported. Magnetic resonance imaging showed pachymeningeal enhancement and other features consistent with SIH and pointed towards a cervical CSF leak site. After failure of conservative treatment, a targeted computer tomography-guided EBP was performed, with complete recovery.

  14. Genetics Home Reference: primary spontaneous pneumothorax

    Science.gov (United States)

    ... Home Health Conditions Primary spontaneous pneumothorax Primary spontaneous pneumothorax Printable PDF Open All Close All Enable Javascript ... view the expand/collapse boxes. Description Primary spontaneous pneumothorax is an abnormal accumulation of air in the ...

  15. Hydrolyzable tannins with the hexahydroxydiphenoyl unit and the m-depsidic link: HPLC-DAD-MS identification and model synthesis.

    Science.gov (United States)

    Arapitsas, Panagiotis; Menichetti, Stefano; Vincieri, Franco F; Romani, Annalisa

    2007-01-10

    This study was designed to develop efficient analytical tools for the difficult HPLC-DAD-MS identification of hydrolyzable tannins in natural tissue extracts. Throughout the study of the spectroscopic characteristics of properly synthesized stereodefined standards, it was observed that the UV-vis spectra of compounds with the m-depsidic link showed a characteristic shoulder at 300 nm, consistent with the simple glucogalloyl esters, whereas compounds with the hexahydroxydiphenoyl (HHDP) unit gave a diagnostic fragmentation pattern, caused by a spontaneous lactonization in the mass spectrometer. These observations were confirmed by HPLC-DAD-MS analyses of tannic acid and raspberry extracts, which are rich in hydrolyzable tannins with the m-depsidic link and the HHDP unit, respectively.

  16. Cardiac remodeling and myocardial dysfunction in obese spontaneously hypertensive rats

    Directory of Open Access Journals (Sweden)

    Linz Dominik

    2012-09-01

    Full Text Available Abstract Background The additive effects of obesity and metabolic syndrome on left ventricular (LV maladaptive remodeling and function in hypertension are not characterized. Methods We compared an obese spontaneously hypertensive rat model (SHR-ob with lean spontaneously hypertensive rats (SHR-lean and normotensive controls (Ctr. LV-function was investigated by cardiac magnetic resonance imaging and invasive LV-pressure measurements. LV-interstitial fibrosis was quantified and protein levels of phospholamban (PLB, Serca2a and glucose transporters (GLUT1 and GLUT4 were determined by immunohistochemistry. Results Systolic blood pressure was similar in SHR-lean and SHR-ob (252 ± 7 vs. 242 ± 7 mmHg, p = 0.398 but was higher when compared to Ctr (155 ± 2 mmHg, p  Conclusion In addition to hypertension alone, metabolic syndrome and obesity adds to the myocardial phenotype by aggravating diastolic dysfunction and a progression towards systolic dysfunction. SHR-ob may be a useful model to develop new interventional and pharmacological treatment strategies for hypertensive heart disease and metabolic disorders.

  17. Observation of Ion Acoustic Waves Excited by Drift Waves in a Weakly Magnetized Plasma

    International Nuclear Information System (INIS)

    Tsukabayashi, Isao; Sato, Sugiya; Nakamura, Yoshiharu

    2003-01-01

    Spontaneous fluctuations excited by drift waves are investigated experimentally in magnetic multi-pole plasma. The magnetic multi-pole has been widely used in DP devices and so on. It was observed that the high level of density fluctuations was generated by the drift instability near a magnetic multi-pole or a dipole magnet. The waves propagate to the middle plasma region forming the envelope train waves

  18. Annealing of magnetic nanoparticles for their encapsulation into microcarriers guided by vascular magnetic resonance navigation

    Energy Technology Data Exchange (ETDEWEB)

    Pouponneau, Pierre; Segura, Vincent [Ecole Polytechnique de Montreal (EPM), NanoRobotics Laboratory, Department of Computer and Software Engineering and Institute of Biomedical Engineering (Canada); Savadogo, Oumarou [Ecole Polytechnique de Montreal (EPM), Laboratoire de Nouveaux Materiaux pour l' electrochimie et l' energie (Canada); Leroux, Jean-Christophe [Universite de Montreal, Faculty of Pharmacy (Canada); Martel, Sylvain, E-mail: sylvain.martel@polymtl.ca [Ecole Polytechnique de Montreal (EPM), NanoRobotics Laboratory, Department of Computer and Software Engineering and Institute of Biomedical Engineering (Canada)

    2012-12-15

    Iron, cobalt and iron-cobalt nanoparticle properties, such as diameter, saturation magnetization (Ms), crystal structure, surface composition and stability in physiological solutions, were investigated according to the annealing temperature used prior to their encapsulation into poly(d, l-lactic-co-glycolic acid) (PLGA) microcarriers. These new 60-{mu}m microparticles should exhibit an Ms around 70 emu g{sup -1} to be guided in real time from their intravascular injection site to a tumor with a magnetic resonance imaging scanner. The challenge in the preparation of the nanoparticles consisted in limiting Ms loss by oxidation and the release of metallic ions. It was found that when the annealing temperature reached 650 Degree-Sign C, Fe nanoparticles coalesced, the mean diameter reached (O) 361 {+-} 138 nm and Ms increased to 171 emu g{sup -1}. These nanoparticles exhibited a core of {alpha}-Fe and a shell of Fe{sub 3}O{sub 4}. On the opposite, Co nanoparticle properties were not affected by the annealing temperature: O and Ms were around 120 nm and 140 emu g{sup -1}, respectively. FeCo (60:40, atomic percent) nanoparticles coalesced at an annealing temperature >550 Degree-Sign C, O and Ms reached 217 nm and 213 emu g{sup -1}, respectively. Co and FeCo nanoparticles with a Co atomic proportion >15 % were coated with a graphite shell when the temperature was set to 550 Degree-Sign C. In physiological solution, Fe and Co nanoparticles significantly released more ions than FeCo nanoparticles. After the preparation steps prior to their encapsulation, the Ms of Fe and FeCo nanoparticles decreased by 25 and 3 %, respectively. FeCo-PLGA microparticles possessed a relatively high Ms (73 emu g{sup -1}) while that of Fe-PLGA microparticle (20 emu g{sup -1}) was too low for efficient targeting. The graphite shell was efficient to preserve Ms during the encapsulation.

  19. First results on quiet and magnetic granulation from SOUP

    Science.gov (United States)

    Title, A. M.; Tarbell, T. D.; Acton, L.; Duncan, D.; Ferguson, S. H.; Finch, M.; Frank, Z.; Kelly, G.; Lindgren, R.; Morrill, M.

    1987-01-01

    The flight of Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 allowed the collection of time sequences of diffraction limited (0.5 arc sec) granulation images with excellent pointing (0.003 arc sec) and completely free of the distortion that plagues groundbased images. The p-mode oscillations are clearly seen in the data. Using Fourier transforms in the temporal and spatial domain, it was shown that the p-modes dominate the autocorrelation lifetime in magnetic regions. When these oscillations are removed the autocorrelation lifetime is found to be 500 sec in quiet and 950 sec in magnetic regions. In quiet areas exploding granules are seen to be common. It is speculated that a significant fraction of granule lifetimes are terminated by nearby explosions. Using local correlation tracking techniques it was able to measure horizontal displacements, and thus transverse velocities, in the magnetic field. In quiet sun it is possible to detect both super and mesogranulation. Horizontal velocities are as great as 1000 m/s and the average velocity is 400 m/s. In magnetic regions horizontal velocities are much less, about 100 m/s.

  20. First results on quiet and magnetic granulation from SOUP

    Science.gov (United States)

    Title, A. M.; Tarbell, T. D.; Acton, L.; Duncan, D.; Ferguson, S. H.; Finch, M.; Frank, Z.; Kelly, G.; Lindgren, R.; Morrill, M.

    1987-09-01

    The flight of Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 allowed the collection of time sequences of diffraction limited (0.5 arc sec) granulation images with excellent pointing (0.003 arc sec) and completely free of the distortion that plagues groundbased images. The p-mode oscillations are clearly seen in the data. Using Fourier transforms in the temporal and spatial domain, it was shown that the p-modes dominate the autocorrelation lifetime in magnetic regions. When these oscillations are removed the autocorrelation lifetime is found to be 500 sec in quiet and 950 sec in magnetic regions. In quiet areas exploding granules are seen to be common. It is speculated that a significant fraction of granule lifetimes are terminated by nearby explosions. Using local correlation tracking techniques it was able to measure horizontal displacements, and thus transverse velocities, in the magnetic field. In quiet sun it is possible to detect both super and mesogranulation. Horizontal velocities are as great as 1000 m/s and the average velocity is 400 m/s. In magnetic regions horizontal velocities are much less, about 100 m/s.

  1. Serum Metabolomics Study Based on LC-MS and Antihypertensive Effect of Uncaria on Spontaneously Hypertensive Rats

    Directory of Open Access Journals (Sweden)

    Ana Liu

    2018-01-01

    Full Text Available Our previous studies have shown that Uncaria has an important role in lowering blood pressure, but its intervention mechanism has not been clarified completely in the metabolic level. Therefore, in this study, a combination method of HPLC-TOF/MS-based metabolomics and multivariate statistical analyses was employed to explore the mechanism and evaluate the antihypertensive effect of Uncaria. Serum samples were analyzed and identified by HPLC-TOF/MS, while the acquired data was further processed by partial least squares discriminant analysis (PLS-DA and orthogonal partial least squares discriminant analysis (OPLS-DA to discover the perturbed metabolites. A clear cluster among the different groups was obtained, and 7 significantly changed potential biomarkers were screened out. These biomarkers were mainly associated with lipid metabolism (dihydroceramide, ceramide, PC, LysoPC, and TXA2 and vitamin and amino acids metabolism (nicotinamide riboside, 5-HTP. The result indicated that Uncaria could decrease the blood pressure effectively, partially by regulating the above biomarkers and metabolic pathways. Analyzing and verifying the specific biomarkers, further understanding of the therapeutic mechanism and antihypertensive effect of Uncaria was acquired. Metabolomics provided a new insight into estimate of the therapeutic effect and dissection of the potential mechanisms of traditional Chinese medicine (TCM in treating hypertension.

  2. Spontaneous remission of acromegaly or gigantism due to subclinical apoplexy of pituitary growth hormone adenoma.

    Science.gov (United States)

    Wang, Xian-Ling; Dou, Jing-Tao; Lü, Zhao-Hui; Zhong, Wen-Wen; Ba, Jian-Ming; Jin, Du; Lu, Ju-Ming; Pan, Chang-Yu; Mu, Yi-Ming

    2011-11-01

    Subclinical apoplexy of pituitary functional adenoma can cause spontaneous remission of hormone hypersecretion. The typical presence of pituitary growth hormone (GH) adenoma is gigantism and/or acromegaly. We investigated the clinical characteristics of patients with spontaneous partial remission of acromegaly or gigantism due to subclinical apoplexy of GH adenoma. Six patients with spontaneous remission of acromegaly or gigantism were enrolled. The clinical characteristics, endocrinological evaluation and imageological characteristics were retrospectively analyzed. In these cases, the initial clinical presences were diabetes mellitus or hypogonadism. No abrupt headache, vomiting, visual function impairment, or conscious disturbance had ever been complained of. The base levels of GH and insulin growth factor-1 (IGF-1) were normal or higher, but nadir GH levels were all still > 1 µg/L in 75 g oral glucose tolerance test. Magnetic resonance imaging detected enlarged sella, partial empty sella and compressed pituitary. The transsphenoidal surgery was performed in 2 cases, and the other patients were conservatively managed. All the patients were in clinical remission. When the clinical presences, endocrine evaluation, biochemical examination and imageology indicate spontaneous remission of GH hypersecretion in patients with gigantism or acromegaly, the diagnosis of subclinical apoplexy of pituitary GH adenoma should be presumed. To these patients, conservative therapy may be appropriate.

  3. Ziprasidone-induced spontaneous orgasm.

    Science.gov (United States)

    Boora, K; Chiappone, K; Dubovsky, S; Xu, J

    2010-06-01

    Neuroleptic treatment in schizophrenic patients has been associated with sexual dysfunction, including impotence and decreased libido. Spontaneous ejaculation without sexual arousal during typical antipsychotic treatment is a rare condition that has been described with zuclopentixol, trifluoperazine, and thiothixene. Here, we are reporting a case of spontaneous orgasm with ziprasidone in a bipolar patient. This patient began to repeatedly experience spontaneous sexual arousal and orgasm, which she had never experienced in the past. Ziprasidone might be causing an increase in sexual orgasm by 5-HT2 receptor antagonism, which preclinical evidence suggests that it facilitates dopamine release in the cortex.

  4. Effect of exercise training on Ca{sup 2+} release units of left ventricular myocytes of spontaneously hypertensive rats

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro-Júnior, M.A. [Universidade Federal do Espírito Santo, Departamento de Ciências Fisiológicas, Vitória, ES (Brazil); Universidade Federal de Viçosa, Laboratório de Biologia do Exercício, Departamento de Educação Física, Viçosa, MG (Brazil); Quintão-Júnior, J.F.; Drummond, L.R.; Lavorato, V.N.; Drummond, F.R. [Universidade Federal de Viçosa, Laboratório de Biologia do Exercício, Departamento de Educação Física, Viçosa, MG (Brazil); Amadeu, M.A.; Oliveira, E.M. [Universidade de São Paulo, Laboratório de Bioquímica e Biologia Molecular do Exercício, Escola de Educação Física e Esportes, São Paulo, SP (Brazil); Felix, L.B. [Universidade Federal de Viçosa, Departamento de Engenharia Elétrica, Viçosa, MG (Brazil); Cruz, J.S. [Universidade Federal de Minas Gerais, Laboratório de Membranas Excitáveis e Biologia Cardiovascular, Departamento de Bioquímica e Imunologia, Belo Horizonte, MG (Brazil); Mill, J.G. [Universidade Federal do Espírito Santo, Departamento de Ciências Fisiológicas, Vitória, ES (Brazil); Natali, A.J.; Prímola-Gomes, T.N. [Universidade Federal de Viçosa, Laboratório de Biologia do Exercício, Departamento de Educação Física, Viçosa, MG (Brazil)

    2014-08-29

    In cardiomyocytes, calcium (Ca{sup 2+}) release units comprise clusters of intracellular Ca{sup 2+} release channels located on the sarcoplasmic reticulum, and hypertension is well established as a cause of defects in calcium release unit function. Our objective was to determine whether endurance exercise training could attenuate the deleterious effects of hypertension on calcium release unit components and Ca{sup 2+} sparks in left ventricular myocytes of spontaneously hypertensive rats. Male Wistar and spontaneously hypertensive rats (4 months of age) were divided into 4 groups: normotensive (NC) and hypertensive control (HC), and normotensive (NT) and hypertensive trained (HT) animals (7 rats per group). NC and HC rats were submitted to a low-intensity treadmill running protocol (5 days/week, 1 h/day, 0% grade, and 50-60% of maximal running speed) for 8 weeks. Gene expression of the ryanodine receptor type 2 (RyR2) and FK506 binding protein (FKBP12.6) increased (270%) and decreased (88%), respectively, in HC compared to NC rats. Endurance exercise training reversed these changes by reducing RyR2 (230%) and normalizing FKBP12.6 gene expression (112%). Hypertension also increased the frequency of Ca{sup 2+} sparks (HC=7.61±0.26 vs NC=4.79±0.19 per 100 µm/s) and decreased its amplitude (HC=0.260±0.08 vs NC=0.324±0.10 ΔF/F{sub 0}), full width at half-maximum amplitude (HC=1.05±0.08 vs NC=1.26±0.01 µm), total duration (HC=11.51±0.12 vs NC=14.97±0.24 ms), time to peak (HC=4.84±0.06 vs NC=6.31±0.14 ms), and time constant of decay (HC=8.68±0.12 vs NC=10.21±0.22 ms). These changes were partially reversed in HT rats (frequency of Ca{sup 2+} sparks=6.26±0.19 µm/s, amplitude=0.282±0.10 ΔF/F{sub 0}, full width at half-maximum amplitude=1.14±0.01 µm, total duration=13.34±0.17 ms, time to peak=5.43±0.08 ms, and time constant of decay=9.43±0.15 ms). Endurance exercise training attenuated the deleterious effects of hypertension on calcium release units of

  5. Presbycusis Disrupts Spontaneous Activity Revealed by Resting-State Functional MRI

    Directory of Open Access Journals (Sweden)

    Yu-Chen Chen

    2018-03-01

    Full Text Available Purpose: Presbycusis, age-related hearing loss, is believed to involve neural changes in the central nervous system, which is associated with an increased risk of cognitive impairment. The goal of this study was to determine if presbycusis disrupted spontaneous neural activity in specific brain areas involved in auditory processing, attention and cognitive function using resting-state functional magnetic resonance imaging (fMRI approach.Methods: Hearing and resting-state fMRI measurements were obtained from 22 presbycusis patients and 23 age-, sex- and education-matched healthy controls. To identify changes in spontaneous neural activity associated with age-related hearing loss, we compared the amplitude of low-frequency fluctuations (ALFF and regional homogeneity (ReHo of fMRI signals in presbycusis patients vs. controls and then determined if these changes were linked to clinical measures of presbycusis.Results: Compared with healthy controls, presbycusis patients manifested decreased spontaneous activity mainly in the superior temporal gyrus (STG, parahippocampal gyrus (PHG, precuneus and inferior parietal lobule (IPL as well as increased neural activity in the middle frontal gyrus (MFG, cuneus and postcentral gyrus (PoCG. A significant negative correlation was observed between ALFF/ReHo activity in the STG and average hearing thresholds in presbycusis patients. Increased ALFF/ReHo activity in the MFG was positively correlated with impaired Trail-Making Test B (TMT-B scores, indicative of impaired cognitive function involving the frontal lobe.Conclusions: Presbycusis patients have disrupted spontaneous neural activity reflected by ALFF and ReHo measurements in several brain regions; these changes are associated with specific cognitive performance and speech/language processing. These findings mainly emphasize the crucial role of aberrant resting-state ALFF/ReHo patterns in presbycusis patients and will lead to a better understanding of the

  6. Presbycusis Disrupts Spontaneous Activity Revealed by Resting-State Functional MRI.

    Science.gov (United States)

    Chen, Yu-Chen; Chen, Huiyou; Jiang, Liang; Bo, Fan; Xu, Jin-Jing; Mao, Cun-Nan; Salvi, Richard; Yin, Xindao; Lu, Guangming; Gu, Jian-Ping

    2018-01-01

    Purpose : Presbycusis, age-related hearing loss, is believed to involve neural changes in the central nervous system, which is associated with an increased risk of cognitive impairment. The goal of this study was to determine if presbycusis disrupted spontaneous neural activity in specific brain areas involved in auditory processing, attention and cognitive function using resting-state functional magnetic resonance imaging (fMRI) approach. Methods : Hearing and resting-state fMRI measurements were obtained from 22 presbycusis patients and 23 age-, sex- and education-matched healthy controls. To identify changes in spontaneous neural activity associated with age-related hearing loss, we compared the amplitude of low-frequency fluctuations (ALFF) and regional homogeneity (ReHo) of fMRI signals in presbycusis patients vs. controls and then determined if these changes were linked to clinical measures of presbycusis. Results : Compared with healthy controls, presbycusis patients manifested decreased spontaneous activity mainly in the superior temporal gyrus (STG), parahippocampal gyrus (PHG), precuneus and inferior parietal lobule (IPL) as well as increased neural activity in the middle frontal gyrus (MFG), cuneus and postcentral gyrus (PoCG). A significant negative correlation was observed between ALFF/ReHo activity in the STG and average hearing thresholds in presbycusis patients. Increased ALFF/ReHo activity in the MFG was positively correlated with impaired Trail-Making Test B (TMT-B) scores, indicative of impaired cognitive function involving the frontal lobe. Conclusions : Presbycusis patients have disrupted spontaneous neural activity reflected by ALFF and ReHo measurements in several brain regions; these changes are associated with specific cognitive performance and speech/language processing. These findings mainly emphasize the crucial role of aberrant resting-state ALFF/ReHo patterns in presbycusis patients and will lead to a better understanding of the

  7. Spontaneous Brain Activity Did Not Show the Effect of Violent Video Games on Aggression: A Resting-State fMRI Study

    Science.gov (United States)

    Pan, Wei; Gao, Xuemei; Shi, Shuo; Liu, Fuqu; Li, Chao

    2018-01-01

    A great many of empirical researches have proved that longtime exposure to violent video game can lead to a series of negative effects. Although research has focused on the neural basis of the correlation between violent video game and aggression, little is known whether the spontaneous brain activity is associated with violent video game exposure. To address this question, we measured the spontaneous brain activity using resting-state functional magnetic resonance imaging (fMRI). We used the amplitude of low-frequency fluctuations (ALFF) and fractional ALFF (fALFF) to quantify spontaneous brain activity. The results showed there is no significant difference in ALFF, or fALFF, between violent video game group and the control part, indicating that long time exposure to violent video games won’t significantly influence spontaneous brain activity, especially the core brain regions such as execution control, moral judgment and short-term memory. This implies the adverse impact of violent video games is exaggerated. PMID:29375416

  8. Spontaneous Brain Activity Did Not Show the Effect of Violent Video Games on Aggression: A Resting-State fMRI Study.

    Science.gov (United States)

    Pan, Wei; Gao, Xuemei; Shi, Shuo; Liu, Fuqu; Li, Chao

    2017-01-01

    A great many of empirical researches have proved that longtime exposure to violent video game can lead to a series of negative effects. Although research has focused on the neural basis of the correlation between violent video game and aggression, little is known whether the spontaneous brain activity is associated with violent video game exposure. To address this question, we measured the spontaneous brain activity using resting-state functional magnetic resonance imaging (fMRI). We used the amplitude of low-frequency fluctuations (ALFF) and fractional ALFF (fALFF) to quantify spontaneous brain activity. The results showed there is no significant difference in ALFF, or fALFF, between violent video game group and the control part, indicating that long time exposure to violent video games won't significantly influence spontaneous brain activity, especially the core brain regions such as execution control, moral judgment and short-term memory. This implies the adverse impact of violent video games is exaggerated.

  9. Spontaneous Brain Activity Did Not Show the Effect of Violent Video Games on Aggression: A Resting-State fMRI Study

    Directory of Open Access Journals (Sweden)

    Wei Pan

    2018-01-01

    Full Text Available A great many of empirical researches have proved that longtime exposure to violent video game can lead to a series of negative effects. Although research has focused on the neural basis of the correlation between violent video game and aggression, little is known whether the spontaneous brain activity is associated with violent video game exposure. To address this question, we measured the spontaneous brain activity using resting-state functional magnetic resonance imaging (fMRI. We used the amplitude of low-frequency fluctuations (ALFF and fractional ALFF (fALFF to quantify spontaneous brain activity. The results showed there is no significant difference in ALFF, or fALFF, between violent video game group and the control part, indicating that long time exposure to violent video games won’t significantly influence spontaneous brain activity, especially the core brain regions such as execution control, moral judgment and short-term memory. This implies the adverse impact of violent video games is exaggerated.

  10. ON THE ROLE OF REPETITIVE MAGNETIC RECONNECTIONS IN EVOLUTION OF MAGNETIC FLUX ROPES IN SOLAR CORONA

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sanjay; Bhattacharyya, R.; Joshi, Bhuwan [Udaipur Solar Observatory, Physical Research Laboratory, Dewali, Bari Road, Udaipur-313001 (India); Smolarkiewicz, P. K. [European Centre for Medium-Range Weather Forecasts, Reading RG2 9AX (United Kingdom)

    2016-10-20

    Parker's magnetostatic theorem, extended to astrophysical magnetofluids with large magnetic Reynolds number, supports ceaseless regeneration of current sheets and, hence, spontaneous magnetic reconnections recurring in time. Consequently, a scenario is possible where the repeated reconnections provide an autonomous mechanism governing emergence of coherent structures in astrophysical magnetofluids. In this work, such a scenario is explored by performing numerical computations commensurate with the magnetostatic theorem. In particular, the computations explore the evolution of a flux rope governed by repeated reconnections in a magnetic geometry resembling bipolar loops of solar corona. The revealed morphology of the evolution process—including onset and ascent of the rope, reconnection locations, and the associated topology of the magnetic field lines—agrees with observations, and thus substantiates physical realizability of the advocated mechanism.

  11. Generation of zonal flows in rotating fluids and magnetized plasmas

    DEFF Research Database (Denmark)

    Juul Rasmussen, J.; Garcia, O.E.; Naulin, V.

    2006-01-01

    The spontaneous generation of large-scale flows by the rectification of small-scale turbulent fluctuations is of great importance both in geophysical flows and in magnetically confined plasmas. These flows regulate the turbulence and may set up effective transport barriers. In the present....... The analogy to large-scale flow generation in drift-wave turbulence dynamics in magnetized plasma is briefly discussed....

  12. Natalizumab Discontinuation and Treatment Strategies in Patients with Multiple Sclerosis (MS): A Retrospective Study from Two Italian MS Centers.

    Science.gov (United States)

    Lo Re, Marianna; Capobianco, Marco; Ragonese, Paolo; Realmuto, Sabrina; Malucchi, Simona; Berchialla, Paola; Salemi, Giuseppe; Bertolotto, Antonio

    2015-12-01

    Natalizumab (NTZ) discontinuation can be followed by multiple sclerosis (MS) disease reactivation. Currently no disease-modifying drug (DMD) has been shown to be able to abolish disease reactivation. The aims of the current study were: (1) to determine the frequency of MS reactivation after NTZ discontinuation; (2) to evaluate predictors of reactivation risk, and (3) to compare the effect of different treatments in reducing this risk. Data from 132 patients with MS followed-up for 2 years before NTZ treatment and 1 year after interruption were collected from two Italian MS centers and retrospectively evaluated. Overall, 72 of 132 patients (54.5%) had relapses after NTZ discontinuation and 60 of 125 patients (48%), who had magnetic resonance imaging, had radiological reactivation. Rebound was observed in 28 of 132 patients (21.2%). A higher number of relapses in the 2 years before NTZ treatment, a longer washout period, and a lower number NTZ infusions correlated with reactivation and rebound. Untreated patients (n = 37) had higher clinical and radiological activity and rebound in comparison to patients receiving DMDs. Moreover, a lower risk of relapses was found in patients treated with second-line therapies (NTZ and fingolimod) than in those treated with first-line therapies (interferon beta, glatiramer acetate, teriflunomide, azathioprine). Interestingly, no disease reactivation in off-label treatment (rituximab, autologous hematopoietic stem cell transplantation) was observed. NTZ discontinuation is a risk for MS reactivation and rebound. An alternative treatment should be promptly resumed mainly in patients with a previous very active disease course and with a shorter NTZ therapy. Second-line therapies demonstrate superiority in preventing relapses after NTZ discontinuation.

  13. Magnetic-field generation and electron-collimation analysis for propagating fast electron beams in overdense plasmas

    International Nuclear Information System (INIS)

    Cai Hongbo; Zhu Shaoping; Chen Mo; Wu Sizhong; He, X. T.; Mima, Kunioki

    2011-01-01

    An analytical fluid model is proposed for artificially collimating fast electron beams produced in the interaction of ultraintense laser pulses with specially engineered low-density-core-high-density-cladding structure targets. Since this theory clearly predicts the characteristics of the spontaneously generated magnetic field and its dependence on the plasma parameters of the targets transporting fast electrons, it is of substantial relevance to the target design for fast ignition. The theory also reveals that the rapid changing of the flow velocity of the background electrons in a transverse direction (perpendicular to the flow velocity) caused by the density jump dominates the generation of a spontaneous interface magnetic field for these kinds of targets. It is found that the spontaneously generated magnetic field reaches as high as 100 MG, which is large enough to collimate fast electron transport in overdense plasmas. This theory is also supported by numerical simulations performed using a two-dimensional particle-in-cell code. It is found that the simulation results agree well with the theoretical analysis.

  14. LC-MS (/MS) in clinical toxicology screening methods.

    Science.gov (United States)

    Viette, Véronique; Hochstrasser, Denis; Fathi, Marc

    2012-01-01

    Toxicological screening is the analysis of biological samples to detect and identify unknown compounds. The high selectivity and sensitivity of liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) technology provide an attractive alternative to the current methods (LC-UV, GC/MS, etc.). For these reasons, an increasing number of applications are being published. This paper is a brief overview of LC-MS(/MS) screening methods developed for clinical toxicology in recent years. Various sample treatments, chromatographic separations and detection by mass spectrometry can be combined to obtain screening methods adapted to the constraints and needs of clinical toxicology laboratories. Currently the techniques are in the hands of specialists, mainly in academic institutions. However, the evolution in technology should allow application of these techniques as a tool in toxicology laboratories, thus allowing a more widespread exploitation of their potential.

  15. Proteomic profiling of renal allograft rejection in serum using magnetic bead-based sample fractionation and MALDI-TOF MS.

    Science.gov (United States)

    Sui, Weiguo; Huang, Liling; Dai, Yong; Chen, Jiejing; Yan, Qiang; Huang, He

    2010-12-01

    Proteomics is one of the emerging techniques for biomarker discovery. Biomarkers can be used for early noninvasive diagnosis and prognosis of diseases and treatment efficacy evaluation. In the present study, the well-established research systems of ClinProt Micro solution incorporated unique magnetic bead sample preparation technology, which, based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS), have become very successful in bioinformatics due to its outstanding performance and reproducibility for discovery disease-related biomarker. We collected fasting blood samples from patients with biopsy-confirmed acute renal allograft rejection (n = 12), chronic rejection (n = 12), stable graft function (n = 12) and also from healthy volunteers (n = 13) to study serum peptidome patterns. Specimens were purified with magnetic bead-based weak cation exchange chromatography and analyzed with a MALDI-TOF mass spectrometer. The results indicated that 18 differential peptide peaks were selected as potential biomarkers of acute renal allograft rejection, and 6 differential peptide peaks were selected as potential biomarkers of chronic rejection. A Quick Classifier Algorithm was used to set up the classification models for acute and chronic renal allograft rejection. The algorithm models recognize 82.64% of acute rejection and 98.96% of chronic rejection episodes, respectively. We were able to identify serum protein fingerprints in small sample sizes of recipients with renal allograft rejection and establish the models for diagnosis of renal allograft rejection. This preliminary study demonstrated that proteomics is an emerging tool for early diagnosis of renal allograft rejection and helps us to better understand the pathogenesis of disease process.

  16. Some practical applications of an ICP-MS instrument

    International Nuclear Information System (INIS)

    Meddings, B.; Ng, R.

    1987-01-01

    An early model commercial ICP-MS instrument (PlasmaQuad from VG Isotopes Limited) was acquired more than two years ago. As a typical analytical laboratory in the metallurgical field, the application of the ICP-MS technique to real sample analysis is the authors prime concern. The process of introducing this state-of-the-art instrument into routine analysis will be described. The modifications and limitations necessary to achieve acceptable precision under normal working conditions will be outlined. In most cases, practical problems can be circumvented with some sacrifice in analytical performance in the area of detection limits and dynamic range. In this presentation, specific applications of the ICP-MS technique in the authors laboratory will be discussed. These include trace analysis on high purity metals such as copper, aluminum, cobalt, nickel etc., on refinery feed samples such as nickel sulfate, mixed cobalt and nickel sulfide, cobalt cathode, samarium oxide etc., on alloys such as cobalt-samarium magnetic materials, nickel or cobalt based alloys used in turbine blades etc. Other applications such as the determination of uranium in phosphate rock, trace analysis on fertilizers, water samples and high purity acids will also be mentioned. The solutions to the practical problems encountered in these applications will be discussed. The analytical power of the ICP-MS technique for real sample analysis will be assessed

  17. Spontaneous spinal epidural hematoma with hemiparesis mimicking acute cerebral infarction: Two case reports

    Science.gov (United States)

    Matsumoto, Hiroaki; Miki, Takanori; Miyaji, Yuki; Minami, Hiroaki; Masuda, Atsushi; Tominaga, Shogo; Yoshida, Yasuhisa; Yamaura, Ikuya; Matsumoto, Shigeo; Natsume, Shigeatsu; Yoshida, Kozo

    2012-01-01

    Context Acute hemiparesis is a common initial presentation of ischemic stroke. Although hemiparesis due to spontaneous spinal epidural hematoma (SSEH) is an uncommon symptom, a few cases have been reported and misdiagnosed as cerebral infarction. Design Case reports of SSEH with acute hemiparesis. Findings In these two cases, acute stroke was suspected initially and administration of intravenous alteplase therapy was considered. In one case, the presentation was neck pain and in the other case, it was Lhermitte's sign; brain magnetic resonance imaging (MRI) and magnetic resonance angiography were negative for signs of ischemic infarction, hemorrhage, or arterial dissection. Cervical MRI was performed and demonstrated SSEH. Conclusion Clinicians who perform intravenous thrombolytic treatment with alteplase need to be aware of this possible contraindication. PMID:22925753

  18. Design and simulation of high accuracy power supplies for injector synchrotron dipole magnets

    International Nuclear Information System (INIS)

    Fathizadeh, M.

    1991-01-01

    The ring magnet of the injector synchrotron consists of 68 dipole magnets. These magnets are connected in series and are energized from two feed points 180 degree apart by two identical 12-phase power supplies. The current in the magnet will be raised linearly to about 1 kA level, and after a small transition period (1 ms to 10 ms typical) the current will be reduced to below the injection level of 60 A. The repetition time for the current waveform is 500 ms. A relatively fast voltage loop along with a high gain current loop are utilized to control the current in the magnet with the required accuracy. Only one regulator circuit is used to control the firing pulses of the two sets of identical 12-phase power supplies. Pspice software was used to design and simulate the power supply performance under ramping and investigate the effect of current changes on the utility voltage and input power factor. A current ripple of ± 2 x 10 -4 and tracking error of ± 5 x 10 -4 was needed

  19. Analysis of acrylamide by LC-MS/MS and GC-MS in processed Japanese foods.

    Science.gov (United States)

    Ono, H; Chuda, Y; Ohnishi-Kameyama, M; Yada, H; Ishizaka, M; Kobayashi, H; Yoshida, M

    2003-03-01

    Acrylamide concentrations in processed foods (63 samples covering 31 product types) from Japan were analysed by LC-MS/MS and GC-MS methods. The limit of detection and limit of quantification of acrylamide were 0.2 ng x ml(-1) (6 fmol) and 0.8 ng x ml(-1) (22 fmol), respectively, by LC-MS/MS, and those of 2,3-dibromopropionamide derived from acrylamide were 12 ng x ml(-1) (52 fmol) and 40 ng x ml(-1) (170 fmol), respectively, by GC-MS. Repeatability given as RSD was 1000 microg x kg(-1). The concentrations in non-whole potato-based snacks, rice crackers processed by grilling or frying, and candied sweet potatoes were lower compared with those in the potato crisps and the whole potato-based fried snacks. One of the whole potato-based fried snacks, however, showed low acrylamide concentration (instant precooked noodles and won-tons were <100 microg x kg(-1) with only one exception. Roasted barley grains for 'Mugi-cha' tea contained 200-600 microg x kg(-1) acrylamide.

  20. Magnetic studies on Layered solid solution Lix(Ni0.4Mn0.6)2-xO2

    Science.gov (United States)

    Nakao, K.; Nakamura, T.; Yamada, Y.; Koshiba, N.

    2011-05-01

    Lix(Ni0.4Mn0.6)2-xO2 (1.09hydroxide as raw materials. All the compounds have a layered rock-salt structure, and the cation mixing degree (Ni2+ occupancy in the Li-layer) decreases with an increase in x. From the low-temperature magnetic measurement, they all have negative Weiss temperature and spontaneous magnetization, that is, they are ferromagnetic materials. Both the Curie temperature and the spontaneous magnetization at 4.2K decrease with an increase in x. These magnetic variations are attributed to the lowering of the cation mixing degree: the magnetic interaction network turns to two-dimensional one with the loss of the inert-layer coupling. These situations may be considered semi-quantitatively using the ferromagnetic cluster model. Additionally, the cation mixing degree has an influence on their electrochemical properties such as cycle fading and rate capability.

  1. Magnetic susceptibility to identify landscape segments on a detailed scale in the region of Jaboticabal, São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Mariana dos Reis Barrios

    2012-08-01

    Full Text Available The agricultural potential is generally assessed and managed based on a one-dimensional vision of the soil profile, however, the increased appreciation of sustainable production has stimulated studies on faster and more accurate evaluation techniques and methods of the agricultural potential on detailed scales. The objective of this study was to investigate the possibility of using soil magnetic susceptibility for the identification of landscape segments on a detailed scale in the region of Jaboticabal, São Paulo State. The studied area has two slope curvatures: linear and concave, subdivided into three landscape segments: upper slope (US, concave, middle slope (MS, linear and lower slope (LS, linear. In each of these segments, 20 points were randomly sampled from a database with 207 samples forming a regular grid installed in each landscape segment. The soil physical and chemical properties, CO2 emissions (FCO2 and magnetic susceptibility (MS of the samples were evaluated represented by: magnetic susceptibility of air-dried fine earth (MS ADFE, magnetic susceptibility of the total sand fraction (MS TS and magnetic susceptibility of the clay fraction (MS Cl in the 0.00 - 0.15 m layer. The principal component analysis showed that MS is an important property that can be used to identify landscape segments, because the correlation of this property within the first principal component was high. The hierarchical cluster analysis method identified two groups based on the variables selected by principal component analysis; of the six selected variables, three were related to magnetic susceptibility. The landscape segments were differentiated similarly by the principal component analysis and by the cluster analysis using only the properties with higher discriminatory power. The cluster analysis of MS ADFE, MS TS and MS Cl allowed the formation of three groups that agree with the segment division established in the field. The grouping by cluster

  2. Spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Haritanti, A.; Karacostas, D.; Drevelengas, A.; Kanellopoulos, V.; Paraskevopoulou, E.; Lefkopoulos, A.; Economou, I.; Dimitriadis, A.S.

    2009-01-01

    Spontaneous intracranial hypotension (SIH) is an uncommon but increasingly recognized syndrome. Orthostatic headache with typical findings on magnetic resonance imaging (MRI) are the key to diagnosis. Delayed diagnosis of this condition may subject patients to unnecessary procedures and prolong morbidity. We describe six patients with SIH and outline the important clinical and neuroimaging findings. They were all relatively young, 20-54 years old, with clearly orthostatic headache, minimal neurological signs (only abducent nerve paresis in two) and diffuse pachymeningeal gadolinium enhancement on brain MRI, while two of them presented subdural hygromas. Spinal MRI was helpful in detecting a cervical cerebrospinal fluid leak in three patients and dilatation of the vertebral venous plexus with extradural fluid collection in another. Conservative management resulted in rapid resolution of symptoms in five patients (10 days-3 weeks) and in one who developed cerebral venous sinus thrombosis, the condition resolved in 2 months. However, this rapid clinical improvement was not accompanied by an analogous regression of the brain MR findings that persisted on a longer follow-up. Along with recent literature data, our patients further point out that SIH, to be correctly diagnosed, necessitates increased alertness by the attending physician, in the evaluation of headaches

  3. Spontaneous rib fractures.

    Science.gov (United States)

    Katrancioglu, Ozgur; Akkas, Yucel; Arslan, Sulhattin; Sahin, Ekber

    2015-07-01

    Other than trauma, rib fracture can occur spontaneously due to a severe cough or sneeze. In this study, patients with spontaneous rib fractures were analyzed according to age, sex, underlying pathology, treatment, and complications. Twelve patients who presented between February 2009 and February 2011 with spontaneous rib fracture were reviewed retrospectively. The patients' data were evaluated according to anamnesis, physical examination, and chest radiographs. The ages of the patients ranged from 34 to 77 years (mean 55.91 ± 12.20 years), and 7 (58.4%) were male. All patients had severe cough and chest pain. The fractures were most frequently between 4th and 9th ribs; multiple rib fractures were detected in 5 (41.7%) patients. Eight (66.7%) patients had chronic obstructive pulmonary disease, 2 (16.7%) had bronchial asthma, and 2 (16.7%) had osteoporosis. Bone densitometry revealed a high risk of bone fracture in all patients. Patients with chronic obstructive pulmonary disease or bronchial asthma had been treated with high-dose steroids for over a year. Spontaneous rib fracture due to severe cough may occur in patients with osteoporosis, chronic obstructive pulmonary disease, or bronchial asthma, receiving long-term steroid therapy. If these patients have severe chest pain, chest radiography should be performed to check for bone lesions. © The Author(s) 2015.

  4. Magnetic properties of permalloy-coated organic tubules

    Science.gov (United States)

    Krebs, J. J.; Rubinstein, M.; Lubitz, P.; Harford, M. Z.; Baral, S.; Shashidar, R.; Ho, Y. S.; Chow, G. M.; Qadri, S.

    1991-11-01

    An initial investigation is presented of the ferromagnetic properties of a novel type of magnetic composite, viz., permalloy-coated submicron diameter hollow cylinders or tubules. The tubules form spontaneously from an organic material, a diacetylenic phosopholipid, and were used as templates on which the ferromagnetic material was deposited by electroless deposition. The permalloy-coated tubules were dispersed in an epoxy matrix to measure the magnetization and ferromagnetic resonance (FMR) properties of individual tubules. The nature of the magnetic anisotropy and the FMR spectra observed confirmed that the tubules are well aligned by a magnetic field during the epoxy curing. The FMR spectra are interpreted in terms of a powder pattern distribution of thin-film spectra consistent with the large diameter-to-thickness ratio.

  5. Effect of exercise training on Ca²⁺ release units of left ventricular myocytes of spontaneously hypertensive rats.

    Science.gov (United States)

    Carneiro-Júnior, M A; Quintão-Júnior, J F; Drummond, L R; Lavorato, V N; Drummond, F R; Amadeu, M A; Oliveira, E M; Felix, L B; Cruz, J S; Mill, J G; Natali, A J; Prímola-Gomes, T N

    2014-11-01

    In cardiomyocytes, calcium (Ca²⁺) release units comprise clusters of intracellular Ca²⁺ release channels located on the sarcoplasmic reticulum, and hypertension is well established as a cause of defects in calcium release unit function. Our objective was to determine whether endurance exercise training could attenuate the deleterious effects of hypertension on calcium release unit components and Ca²⁺ sparks in left ventricular myocytes of spontaneously hypertensive rats. Male Wistar and spontaneously hypertensive rats (4 months of age) were divided into 4 groups: normotensive (NC) and hypertensive control (HC), and normotensive (NT) and hypertensive trained (HT) animals (7 rats per group). NC and HC rats were submitted to a low-intensity treadmill running protocol (5 days/week, 1 h/day, 0% grade, and 50-60% of maximal running speed) for 8 weeks. Gene expression of the ryanodine receptor type 2 (RyR2) and FK506 binding protein (FKBP12.6) increased (270%) and decreased (88%), respectively, in HC compared to NC rats. Endurance exercise training reversed these changes by reducing RyR2 (230%) and normalizing FKBP12.6 gene expression (112%). Hypertension also increased the frequency of Ca²⁺ sparks (HC=7.61 ± 0.26 vs NC=4.79 ± 0.19 per 100 µm/s) and decreased its amplitude (HC=0.260 ± 0.08 vs NC=0.324 ± 0.10 ΔF/F0), full width at half-maximum amplitude (HC=1.05 ± 0.08 vs NC=1.26 ± 0.01 µm), total duration (HC=11.51 ± 0.12 vs NC=14.97 ± 0.24 ms), time to peak (HC=4.84 ± 0.06 vs NC=6.31 ± 0.14 ms), and time constant of decay (HC=8.68 ± 0.12 vs NC=10.21 ± 0.22 ms). These changes were partially reversed in HT rats (frequency of Ca²⁺ sparks=6.26 ± 0.19 µm/s, amplitude=0.282 ± 0.10 ΔF/F0, full width at half-maximum amplitude=1.14 ± 0.01 µm, total duration=13.34 ± 0.17 ms, time to peak=5.43 ± 0.08 ms, and time constant of decay=9.43 ± 0.15 ms). Endurance exercise training attenuated the deleterious effects of hypertension on calcium release

  6. A polarity-induced defect mechanism for conductivity and magnetism at polar-nonpolar oxide interfaces.

    Science.gov (United States)

    Yu, Liping; Zunger, Alex

    2014-10-13

    The discovery of conductivity and magnetism at the polar-nonpolar interfaces of insulating nonmagnetic oxides such as LaAlO3 and SrTiO3 has raised prospects for attaining interfacial functionalities absent in the component materials. Yet, the microscopic origin of such emergent phenomena remains unclear, posing obstacles to design of improved functionalities. Here we present first principles calculations of electronic and defect properties of LaAlO3/SrTiO3 interfaces and reveal a unifying mechanism for the origins of both conductivity and magnetism. We demonstrate that the polar discontinuity across the interface triggers thermodynamically the spontaneous formation of certain defects that in turn cancel the polar field induced by the polar discontinuity. The ionization of the spontaneously formed surface oxygen vacancy defects leads to interface conductivity, whereas the unionized Ti-on-Al antisite defects lead to interface magnetism. The proposed mechanism suggests practical design principles for inducing and controlling both conductivity and magnetism at general polar-nonpolar interfaces.

  7. Characterisation of phenolic compounds by UPLC-QTOF-MS/MS of geopropolis from the stingless bee Melipona subnitida (jandaíra).

    Science.gov (United States)

    de Souza, Silvana Alves; da Silva, Telma Maria Guedes; da Silva, Eva Monica Sarmento; Camara, Celso Amorim; Silva, Tania Maria Sarmento

    2018-05-17

    Melipona subnitida Ducke (jandaíra) is a stingless bee native to north-eastern Brazil, which produces geopropolis, a mixture of beeswax, plant resins, pollens and earth that is used for sealing beehives. To extend the knowledge on phenolic compounds in fractions obtained by C18-solid phase extraction (SPE) of nine geopropolis samples from Melipona subnitida collected at different times. Chromatographic profiles of nine samples of geopropolis from jandaíra were analysed by ultra-performance liquid chromatography coupled with a diode array detector and quadrupole time-of-flight mass spectrometry (UPLC-DAD-QTOF-MS/MS) and combined with the use of data-independent acquisition (MSE) for the profiling and structural characterisation of the phenolic compounds. The isolated compound was identified by nuclear magnetic resonance of hydrogen and carbon ( 1 H- and 13 C-NMR). The present study with geopropolis of jandaíra resulted in the characterisation of 51 phenolics by UPLC-DAD-QTOF-MS/MS: four galloyl glucosides, one ellagic acid, 11 acyl-hexosides, 23 acyl-galloyl-hexosides and 12 flavonoids. The structures of two compounds (1,6-di-O-(E)-coumaroyl-2-O-galloyl-β-d-glucopyranoside and 1-O-cinnamoyl-6-O-(E)-coumaroyl-2-O-galloyl-β-d-glucopyranoside) were established by 1 H and the attached proton test (APT) experiments as well as high-resolution electrospray ionisation mass spectroscopy (HR-ESI-MS) analysis. The geopropolis of jandaíra showed phenolic compounds galloyl hexosides, ellagic acid, acyl-(cinnamoyl/coumaroyl)-hexosides, acyl-(cinnamoyl/coumaroyl)-galloyl-hexosides and flavonoids (aglycones and acylated-O-glycosides). Copyright © 2018 John Wiley & Sons, Ltd.

  8. Urinary amino acid analysis: a comparison of iTRAQ-LC-MS/MS, GC-MS, and amino acid analyzer.

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J

    2009-07-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27+/-5.22, 21.18+/-10.94, and 18.34+/-14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39+/-5.35, 6.23+/-3.84, and 35.37+/-29.42. Both GC-MS and iTRAQ-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.

  9. Magnetic resonance imaging appearance at 1. 5 tesla of cartilaginous tumors involving the epiphysis

    Energy Technology Data Exchange (ETDEWEB)

    Fobben, E.S.; Dalinka, M.K.; Schiebler, M.L.; Burk, D.L.; Kressel, H.Y.; Fallon, M.D.; Schmidt, R.G.

    1987-11-01

    Three cases of lytic, calcified epiphyseal lesions with plain film and computed tomography features suggestive of chondroblastoma were imaged by magnetic resonance imaging. Histopathologic correlation was obtained in each case. Two cases of chondroblastoma showed low signal intensity on both short (TR600/TE20ms) and long (TR2500/TE80ms) spin echo (SE) images. The third case, a clear cell chondrosarcoma, demonstrated increased signal intensity on moderately T2 weighted (TR2500/TE40ms) images. These findings suggest that magnetic resonance imaging may be helpful in distinguishing these lesions. (orig.)

  10. Examination of the role of magnetic resonance imaging in multiple sclerosis: A problem-orientated approach

    Directory of Open Access Journals (Sweden)

    McFarland Henry

    2009-01-01

    Full Text Available Magnetic Resonance Imaging (MRI has brought in several benefits to the study of Multiple Sclerosis (MS. It provides accurate measurement of disease activity, facilitates precise diagnosis, and aid in the assessment of newer therapies. The imaging guidelines for MS are broadly divided in to approaches for imaging patients with suspected MS or clinically isolated syndromes (CIS or for monitoring patients with established MS. In this review, the technical aspects of MR imaging for MS are briefly discussed. The imaging process need to capture the twin aspects of acute MS viz. the autoimmune acute inflammatory process and the neurodegenerative process. Gadolinium enhanced MRI can identify acute inflammatory lesions precisely. The commonly applied MRI marker of disease progression is brain atrophy. Whole brain magnetization Transfer Ratio (MTR and Magnetic Resonance Spectroscopy (MRS are two other techniques use to monitor disease progression. A variety of imaging techniques such as Double Inversion Recovery (DIR, Spoiled Gradient Recalled (SPGR acquisition, and Fluid Attenuated Inversion Recovery (FLAIR have been utilized to study the cortical changes in MS. MRI is now extensively used in the Phase I, II and III clinical trials of new therapies. As the technical aspects of MRI advance rapidly, and higher field strengths become available, it is hoped that the impact of MRI on our understanding of MS will be even more profound in the next decade.

  11. Spontaneous Temporal Pole Encephalocele Presenting with Epilepsy: Report of Two Cases.

    Science.gov (United States)

    Shimada, Seijiro; Kunii, Naoto; Kawai, Kensuke; Usami, Kenichi; Matsuo, Takeshi; Uno, Takeshi; Koizumi, Tomoyuki; Saito, Nobuhito

    2015-09-01

    Refractory temporal lobe epilepsy due to spontaneous temporal pole encephalocele is a rare but increasingly recognized condition. Optimal surgical management is complicated by the lack of knowledge regarding both the extent of the epileptogenic area and the need for repair of the encephalocele. We report two cases that add significant information to these issues. In Case 1, with a 5-year history of refractory seizures, implantation of diagnostic subdural electrodes into the anterior temporal base happened to abolish the seizures completely. No structural changes were evident on postoperative magnetic resonance imaging. In Case 2, with a large encephalocele and a 5-year history of refractory seizures, surgical disconnection of the temporal pole successfully abolished seizures without any need for encephalocele repair. These two cases support the view that the epileptogenic area is confined to within the temporal pole for spontaneous temporal pole encephalocele. Temporopolar disconnection represents one surgical option for this entity that achieves seizure cessation without requiring extra repair procedures. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Four-loop on-shell integrals. MS-on-shell relation and g-2

    Energy Technology Data Exchange (ETDEWEB)

    Marquard, P.

    2013-12-15

    We present first results towards a full four-loop calculation for both the anomalous magnetic moment of the muon and the MS-on-shell relation. The calculation requires the detailed study of an up to now not considered class of diagrams, so-called on-shell diagrams, at four-loop order.

  13. Urinary Amino Acid Analysis: A Comparison of iTRAQ®-LC-MS/MS, GC-MS, and Amino Acid Analyzer

    Science.gov (United States)

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L.; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J.

    2009-01-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. PMID:19481989

  14. New permanent magnets

    Science.gov (United States)

    Müller, K.-H.; Krabbes, G.; Fink, J.; Gruß, S.; Kirchner, A.; Fuchs, G.; Schultz, L.

    2001-05-01

    Permanent magnets play an important role and are widely spread in daily-life applications. Due to their very low costs, large availability of the row materials and their high chemical stability, hard ferrites are still dominant in the permanent magnet market although their relatively poor magnetic properties are a distinct disadvantage. Today's high-performance magnets are mostly made from Nd 2Fe 14B. The aim of research is to combine the large spontaneous magnetization of 3d metals with strong anisotropy fields known from rare-earth transition-metal compounds and, at the same time, to maintain a high value of the Curie temperature. However, the number of iron-rich rare-earth intermetallics is very limited and, consequently, not much success can be noted in this field for the last 10 years. One alternative concept is to use magnetic fields trapped in type II superconductors where much higher fields can be achieved compared to conventional rare-earth magnets. Very recently, we obtained a trapped field as high as 14.4 T in a melt-textured YBCO bulk sample of a few centimeters in diameter. This is the highest value ever achieved in a bulk superconductor. The trapped field of a superconductor is not governed by the Laplace equation and, therefore, levitation works without any additional (active) stabilization. The disadvantage of these magnets is their low working temperature (of liquid nitrogen and below).

  15. Altered spontaneous brain activity in patients with hemifacial spasm: a resting-state functional MRI study.

    Directory of Open Access Journals (Sweden)

    Ye Tu

    Full Text Available Resting-state functional magnetic resonance imaging (fMRI has been used to detect the alterations of spontaneous neuronal activity in various neurological and neuropsychiatric diseases, but rarely in hemifacial spasm (HFS, a nervous system disorder. We used resting-state fMRI with regional homogeneity (ReHo analysis to investigate changes in spontaneous brain activity of patients with HFS and to determine the relationship of these functional changes with clinical features. Thirty patients with HFS and 33 age-, sex-, and education-matched healthy controls were included in this study. Compared with controls, HFS patients had significantly decreased ReHo values in left middle frontal gyrus (MFG, left medial cingulate cortex (MCC, left lingual gyrus, right superior temporal gyrus (STG and right precuneus; and increased ReHo values in left precentral gyrus, anterior cingulate cortex (ACC, right brainstem, and right cerebellum. Furthermore, the mean ReHo value in brainstem showed a positive correlation with the spasm severity (r = 0.404, p = 0.027, and the mean ReHo value in MFG was inversely related with spasm severity in HFS group (r = -0.398, p = 0.028. This study reveals that HFS is associated with abnormal spontaneous brain activity in brain regions most involved in motor control and blinking movement. The disturbances of spontaneous brain activity reflected by ReHo measurements may provide insights into the neurological pathophysiology of HFS.

  16. Magnetic resonance in multiple sclerose twins

    International Nuclear Information System (INIS)

    Polman, C.H.; UitdeHaag, B.M.J.; Koetsier, C.J.; Valk, J.; Lucas, C.J.

    1989-01-01

    Magnetic resonance imaging (MR) examinations were performed in a series of 7 twin sets (4 monozygotic and 3 dizygotic) and one triplet set who were clinically discordant for multiple sclerosis (MS). MRI abnormalities were detected in a number of the unaffected members of the nonzygotic twin pairs. The authors discuss the possible implications of their findings for the present view on the aetiology of MS. (author). 3 refs.; 1 fig.; 1 tab

  17. Spontaneous tension haemopneumothorax.

    Science.gov (United States)

    Patterson, Benjamin Oliver; Itam, Sarah; Probst, Fey

    2008-10-31

    We present a patient with sudden onset progressive shortness of breath and no history of trauma, who rapidly became haemodynamically compromised with a pneumothorax and pleural effusion seen on chest radiograph. He was treated for spontaneous tension pneumothorax but this was soon revealed to be a tension haemopneumothorax. He underwent urgent thoracotomy after persistent bleeding to explore an apical vascular abnormality seen on CT scanning. To our knowledge this is the first such case reported.Aetiology and current approach to spontaneous haemothorax are discussed briefly.

  18. Distinct Temporal Coordination of Spontaneous Population Activity between Basal Forebrain and Auditory Cortex

    Directory of Open Access Journals (Sweden)

    Josue G. Yague

    2017-09-01

    Full Text Available The basal forebrain (BF has long been implicated in attention, learning and memory, and recent studies have established a causal relationship between artificial BF activation and arousal. However, neural ensemble dynamics in the BF still remains unclear. Here, recording neural population activity in the BF and comparing it with simultaneously recorded cortical population under both anesthetized and unanesthetized conditions, we investigate the difference in the structure of spontaneous population activity between the BF and the auditory cortex (AC in mice. The AC neuronal population show a skewed spike rate distribution, a higher proportion of short (≤80 ms inter-spike intervals (ISIs and a rich repertoire of rhythmic firing across frequencies. Although the distribution of spontaneous firing rate in the BF is also skewed, a proportion of short ISIs can be explained by a Poisson model at short time scales (≤20 ms and spike count correlations are lower compared to AC cells, with optogenetically identified cholinergic cell pairs showing exceptionally higher correlations. Furthermore, a smaller fraction of BF neurons shows spike-field entrainment across frequencies: a subset of BF neurons fire rhythmically at slow (≤6 Hz frequencies, with varied phase preferences to ongoing field potentials, in contrast to a consistent phase preference of AC populations. Firing of these slow rhythmic BF cells is correlated to a greater degree than other rhythmic BF cell pairs. Overall, the fundamental difference in the structure of population activity between the AC and BF is their temporal coordination, in particular their operational timescales. These results suggest that BF neurons slowly modulate downstream populations whereas cortical circuits transmit signals on multiple timescales. Thus, the characterization of the neural ensemble dynamics in the BF provides further insight into the neural mechanisms, by which brain states are regulated.

  19. Spontaneous lateral temporal encephalocele.

    Science.gov (United States)

    Tuncbilek, Gokhan; Calis, Mert; Akalan, Nejat

    2013-01-01

    A spontaneous encephalocele is one that develops either because of embryological maldevelopment or from a poorly understood postnatal process that permits brain herniation to occur. We here report a rare case of lateral temporal encephalocele extending to the infratemporal fossa under the zygomatic arch. At birth, the infant was noted to have a large cystic mass in the right side of the face. After being operated on initially in another center in the newborn period, the patient was referred to our clinic with a diagnosis of temporal encephalocele. He was 6 months old at the time of admission. Computerized tomography scan and magnetic resonance imaging studies revealed a 8 × 9 cm fluid-filled, multiloculated cystic mass at the right infratemporal fossa. No intracranial pathology or connection is seen. The patient was operated on to reduce the distortion effect of the growing mass. The histopathological examination of the sac revealed well-differentiated mature glial tissue stained with glial fibrillary acid protein. This rare clinical presentation of encephaloceles should be taken into consideration during the evaluation of the lateral facial masses in the infancy period, and possible intracranial connection should be ruled out before surgery to avoid complications.

  20. Selenium speciation analysis of Misgurnus anguillicaudatus selenoprotein by HPLC-ICP-MS and HPLC-ESI-MS/MS

    Science.gov (United States)

    Analytical methods for selenium (Se) speciation were developed using high performance liquid chromatography (HPLC) coupled to either inductively coupled plasma mass spectrometry (ICP-MS) or electrospray ionization tandem mass spectrometry (ESI-MS/MS). Separations of selenomethionine (Se-Met) and sel...

  1. MassSieve: Panning MS/MS peptide data for proteins

    OpenAIRE

    Slotta, Douglas J.; McFarland, Melinda A.; Markey, Sanford P.

    2010-01-01

    We present MassSieve, a Java-based platform for visualization and parsimony analysis of single and comparative LC-MS/MS database search engine results. The success of mass spectrometric peptide sequence assignment algorithms has led to the need for a tool to merge and evaluate the increasing data set sizes that result from LC-MS/MS-based shotgun proteomic experiments. MassSieve supports reports from multiple search engines with differing search characteristics, which can increase peptide sequ...

  2. Magnetic studies on Layered solid solution Lix(Ni0.4Mn0.6)2-xO2

    International Nuclear Information System (INIS)

    Nakao, K; Nakamura, T; Yamada, Y; Koshiba, N

    2011-01-01

    Li x (Ni 0.4 Mn 0.6 ) 2-x O 2 (1.09≤x≤1.23) were prepared by the solid-state reaction using LiOH and coprecipitated mixed hydroxide as raw materials. All the compounds have a layered rock-salt structure, and the cation mixing degree (Ni 2+ occupancy in the Li-layer) decreases with an increase in x. From the low-temperature magnetic measurement, they all have negative Weiss temperature and spontaneous magnetization, that is, they are ferromagnetic materials. Both the Curie temperature and the spontaneous magnetization at 4.2K decrease with an increase in x. These magnetic variations are attributed to the lowering of the cation mixing degree: the magnetic interaction network turns to two-dimensional one with the loss of the inert-layer coupling. These situations may be considered semi-quantitatively using the ferromagnetic cluster model. Additionally, the cation mixing degree has an influence on their electrochemical properties such as cycle fading and rate capability.

  3. Radiologic Diagnosis of Spondylodiscitis, Role of Magnetic Resonance

    OpenAIRE

    Ramadani, Naser; Dedushi, Kreshnike; Kabashi, Serbeze; Mucaj, Sefedin

    2017-01-01

    Introduction: Study aim is to report the Magnetic Resonance Imaging (MRI) features of acute and chronic spontaneous spondylodiscitis. Case report: 57 year old female, complaining of a fever and longstanding cervical pain worsened during physical therapy. Methods: MR images were acquired using superconductive magnet 1.5 T, with the following sequences: sagittal PD and T2 TSE, sagittal T1 SE, axial PD and T2 TSE (lumbar spine), axial T2 GRE (cervical spine). Axial and sagittal T1 SE after admin...

  4. A comparative study on magnetism in Zn-doped AlN and GaN from first-principles

    International Nuclear Information System (INIS)

    Xu, Liang; Wang, Lingling; Huang, Weiqing; Xiao, Wenzhi; Xiao, Gang

    2014-01-01

    First-principles calculations have been used to comparatively investigate electronic and magnetic properties of Zn-doped AlN and GaN. A total magnetic moment of 1.0 μ B induced by Zn is found in AlN, but not in GaN. Analyses show that the origin of spontaneous polarization not only depend on the localized atomic orbitals of N and sufficient hole concentration, but also the relative intensity of the covalency of matrix. The relatively stronger covalent character of GaN with respect to AlN impedes forming local magnetic moment in GaN matrix. Our study offers a fresh sight of spontaneous spin polarization in d 0 magnetism. The much stronger ferromagnetic coupling in c-plane of AlN means that it is feasible to realize long-range ferromagnetic order via monolayer delta-doping. This can apply to other wide band-gap semiconductors in wurtzite structure.

  5. Age determination of vessel wall hematoma in spontaneous cervical artery dissection: A multi-sequence 3T Cardiovascular Magnetic resonance study

    Science.gov (United States)

    2011-01-01

    Background Previously proposed classifications for carotid plaque and cerebral parenchymal hemorrhages are used to estimate the age of hematoma according to its signal intensities on T1w and T2w MR images. Using these classifications, we systematically investigated the value of cardiovascular magnetic resonance (CMR) in determining the age of vessel wall hematoma (VWH) in patients with spontaneous cervical artery dissection (sCAD). Methods 35 consecutive patients (mean age 43.6 ± 9.8 years) with sCAD received a cervical multi-sequence 3T CMR with fat-saturated black-blood T1w-, T2w- and TOF images. Age of sCAD was defined as time between onset of symptoms (stroke, TIA or Horner's syndrome) and the CMR scan. VWH were categorized into hyperacute, acute, early subacute, late subacute and chronic based on their signal intensities on T1w- and T2w images. Results The mean age of sCAD was 2.0, 5.8, 15.7 and 58.7 days in patients with acute, early subacute, late subacute and chronic VWH as classified by CMR (p hematomas with Cohen's kappa of 0.74 (p hematomas differs from that of cerebral hematomas. PMID:22122756

  6. Serial contrast-enhanced magnetic resonance and magnetization transfer in the study of patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Rovira, A.; Alonso, J.; Cucurella, G.; Nos, C.; Tintore, M.; Pedraza, S.; Rio, J.; Montalban, X.

    1997-01-01

    To demonstrate the changes in the magnetization transfer ratio (MTR) of different demyelinating plaques, correlating them with the baseline values in T1-weighted contrast-enhanced magnetic resonance (MR) sequences in order to relate them more closely to the underlying disease. The study was based on 33 demyelinating plaques obtained from six patients clinically diagnosed as having remitting-recurring multiple sclerosis (MS). All the patients underwent two MR studies at a 3 to 5-month interval, including contrast-enhanced T1 and T2- weighted sequences and magnetization transfer images. The latter were used to calculate the MTR for each of the demyelinating plaques included in the study. The statistical analysis of the results obtained revealed statistically significant between initial MTR values and those of subsequent T1-weighted sequences. The MTR demonstrate significant differences between plaques according to contrast-enhanced T1-weigh tes sequences, probably indicating variable degrees of edema, demyelination and tissue destruction. These differences should be taken into account to enable the use of T1-weighted sequences to quantify the lesion load in MS patients. (Author) 35 refs

  7. Spontaneous tension haemopneumothorax

    Directory of Open Access Journals (Sweden)

    Itam Sarah

    2008-10-01

    Full Text Available Abstract We present a patient with sudden onset progressive shortness of breath and no history of trauma, who rapidly became haemodynamically compromised with a pneumothorax and pleural effusion seen on chest radiograph. He was treated for spontaneous tension pneumothorax but this was soon revealed to be a tension haemopneumothorax. He underwent urgent thoracotomy after persistent bleeding to explore an apical vascular abnormality seen on CT scanning. To our knowledge this is the first such case reported. Aetiology and current approach to spontaneous haemothorax are discussed briefly.

  8. Spontaneous compactification to homogeneous spaces

    International Nuclear Information System (INIS)

    Mourao, J.M.

    1988-01-01

    The spontaneous compactification of extra dimensions to compact homogeneous spaces is studied. The methods developed within the framework of coset space dimensional reduction scheme and the most general form of invariant metrics are used to find solutions of spontaneous compactification equations

  9. Situation and person attributions under spontaneous and intentional instructions: an fMRI study.

    Science.gov (United States)

    Kestemont, Jenny; Vandekerckhove, Marie; Ma, Ning; Van Hoeck, Nicole; Van Overwalle, Frank

    2013-06-01

    This functional magnetic resonance imaging (fMRI) research explores how observers make causal beliefs about an event in terms of the person or situation. Thirty-four participants read various short descriptions of social events that implied either the person or the situation as the cause. Half of them were explicitly instructed to judge whether the event was caused by something about the person or the situation (intentional inferences), whereas the other half was instructed simply to read the material carefully (spontaneous inferences). The results showed common activation in areas related to mentalizing, across all types of causes or instructions (posterior superior temporal sulcus, temporo-parietal junction, precuneus). However, the medial prefrontal cortex was activated only under spontaneous instructions, but not under intentional instruction. This suggests a bias toward person attributions (e.g. fundamental attribution bias). Complementary to this, intentional situation attributions activated a stronger and more extended network compared to intentional person attributions, suggesting that situation attributions require more controlled, extended and broader processing of the information.

  10. Case of spontaneous ventriculocisternostomy

    Energy Technology Data Exchange (ETDEWEB)

    Yamane, Kanji; Yoshimoto, Hisanori; Harada, Kiyoshi; Uozumi, Tohru [Hiroshima Univ. (Japan). School of Medicine; Kuwabara, Satoshi

    1983-05-01

    The authors experienced a case of spontaneous ventriculocisternostomy diagnosed by CT scan with metrizamide and Conray. Patient was 23-year-old male who had been in good health until one month before admission, when he began to have headache and tinnitus. He noticed bilateral visual acuity was decreased about one week before admission and vomiting appeared two days before admission. He was admitted to our hospital because of bilateral papilledema and remarkable hydrocephalus diagnosed by CT scan. On admission, no abnormal neurological signs except for bilateral papilledema were noted. Immediately, right ventricular drainage was performed. Pressure of the ventricle was over 300mmH/sub 2/O and CSF was clear. PVG and PEG disclosed an another cavity behind the third ventricle, which was communicated with the third ventricle, and occlusion of aqueduct of Sylvius. Metrizamide CT scan and Conray CT scan showed a communication between this cavity and quadrigeminal and supracerebellar cisterns. On these neuroradiological findings, the diagnosis of obstructive hydrocephalus due to benign aqueduct stenosis accompanied with spontaneous ventriculocisternostomy was obtained. Spontaneous ventriculocisternostomy was noticed to produce arrest of hydrocephalus, but with our case, spontaneous regression of such symptoms did not appeared. By surgical ventriculocisternostomy (method by Torkildsen, Dandy, or Scarff), arrest of hydrocephalus was seen in about 50 to 70 per cent, which was the same results as those of spontaneous ventriculocisternostomy. It is concluded that VP shunt or VA shunt is thought to be better treatment of obstructive hydrocephalus than the various kinds of surgical ventriculocisternostomy.

  11. Design and simulation of high accuracy power supplies for injector synchrotron dipole magnets

    International Nuclear Information System (INIS)

    Fathizadeh, M.

    1991-01-01

    The ring magnet of the injector synchrotron consists of 68 dipole magnets. These magnets are connected in series and are energized from two feed points 180 degrees apart by two identical 12-phase power supplies. The current in the magnet will be raised linearly at about 1 kA level, and after a small transition period (1 ms to 10 ms typical) the current will be reduced to below the injection level of 60 A. The repetition time for the current waveform is 500 ms. A relatively fast voltage loop along with a high gain current loop are utilized to control the current in the magnet with the required accuracy. Only one regulator circuit is used to control the firing pulses of the two sets of identical 12-phase power supplies. Pspice software was used to design and simulate the power supply performance under ramping and investigate the effect of current changes on the utility voltage and input power factor. A current ripple of ±2x10 -4 and tracking error of ±5x10 -4 was needed. 3 refs., 5 figs

  12. Spontaneous intraorbital hematoma: case report

    Directory of Open Access Journals (Sweden)

    Vinodan Paramanathan

    2010-12-01

    Full Text Available Vinodan Paramanathan, Ardalan ZolnourianQueen's Hospital NHS Foundation Trust, Burton on Trent, Staffordshire DE13 0RB, UKAbstract: Spontaneous intraorbital hematoma is an uncommon clinical entity seen in ophthalmology practice. It is poorly represented in the literature. Current evidence attributes it to orbital trauma, neoplasm, vascular malformations, acute sinusitis, and systemic abnormalities. A 65-year-old female presented with spontaneous intraorbital hematoma manifesting as severe ocular pains, eyelid edema, proptosis, and diplopia, without a history of trauma. Computer tomography demonstrated a fairly well defined extraconal lesion with opacification of the paranasal sinuses. The principal differential based on all findings was that of a spreading sinus infection and an extraconal tumor. An unprecedented finding of a spontaneous orbital hematoma was discovered when the patient was taken to theater. We discuss the rarity of this condition and its management.Keywords: hemorrhage, ophthalmology, spontaneous, intra-orbital, hematoma

  13. BOLD magnetic resonance imaging in nephrology

    OpenAIRE

    Hall ME; Jordan JH; Juncos LA; Hundley WG; Hall JE

    2018-01-01

    Michael E Hall,1,2 Jennifer H Jordan,3 Luis A Juncos,1,2 W Gregory Hundley,3 John E Hall2 1Department of Medicine, University of Mississippi Medical Center, Jackson, MS, USA; 2Department of Physiology and Biophysics, University of Mississippi Medical Center, Jackson, MS, USA; 3Department of Internal Medicine, Section on Cardiovascular Medicine, Wake Forest University School of Medicine, Winston-Salem, NC, USA Abstract: Magnetic resonance (MR) imaging, a non-invasive modality that provides ana...

  14. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Area Donate Donate Search v What Is MS? Definition of MS What Causes MS? Who Gets MS? ... Support Personal Stories d What Is MS? d Definition of MS Myelin Immune-Mediated Disease T Cells ...

  15. Concepts and limitations of macroparticle accelerators using travelling magnetic waves

    International Nuclear Information System (INIS)

    Wipf, S.L.

    1980-01-01

    The concept of an accelerator using a travelling magnetic wave acting on magnetized projectiles is discussed. Although superconductors have a high potential as projectile material, their low critical temperature makes them unsuitable. Among ferromagnetic materials dysprosium seems to be superior. For stable suspension and guidance a high conductivity, preferably superconducting, guide sheet is necessary. Magnetic field gradients of 10 9 A/m 2 travelling at 10 6 m/s should be achievable using present state-of-the-art components; resulting accelerations are greater than or equal to 500 km/s 2 . A linear accelerator for final speeds of 50 km/s needs a length of 2.5 km. Guidance forces sufficient to produce acceleration of 2 x 10 6 m/s 2 allow circular accelerators of reasonable size to achieve hypervelocities for small (50 to 100 mg) projectiles. An accelerator of 170 m diameter would surpass the best results from light gas guns. Travelling waves suitable for accelerations of the order of 10 4 m/s 2 can be produced without switching, by means of flux displacing rotors, easily adapted to circular accelerators

  16. Metabolic profiling of roots of liquorice (Glycyrrhiza glabra) from different geographical areas by ESI/MS/MS and determination of major metabolites by LC-ESI/MS and LC-ESI/MS/MS.

    Science.gov (United States)

    Montoro, Paola; Maldini, Mariateresa; Russo, Mariateresa; Postorino, Santo; Piacente, Sonia; Pizza, Cosimo

    2011-02-20

    Liquid chromatography electrospray mass spectrometry (LC-ESI/MS) has been applied to the full characterization of saponins and phenolics in hydroalcoholic extracts of roots of liquorice (Glycyrrhiza glabra). Relative quantitative analyses of the samples with respect to the phenolic constituents and to a group of saponins related to glycyrrhizic acid were performed using LC-ESI/MS. For the saponin constituents, full scan LC-MS/MS fragmentation of the protonated (positive ion mode) or deprotonated (negative ion mode) molecular species generated diagnostic fragment ions that provided information concerning the triterpene skeleton and the number and nature of the substituents. On the basis of the specific fragmentation of glycyrrhizic acid, an LC-MS/MS method was developed in order to quantify the analyte in the liquorice root samples. Chinese G. glabra roots contained the highest levels of glycyrrhizic acid, followed by those from Italy (Calabria). Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Effect of magnetic islands on the impurity transport in a tokamak

    International Nuclear Information System (INIS)

    Ivanov, N.V.; Khvostenko, P.P.; Chudnovskij, A.N.

    1986-01-01

    Effect of magnetic islands m=2, created in plasma with the help of special quadrupole winding, on the behaviour of impurity in the T-7 tokamak is studied. The use of quadrupole winding permitted to exlude the magnetic island nonstationarity typical to spontaneous development of the Tiaring instability. The results obtained confirm the point of view that splitting of rational magnetic surface results in the change of impurity ion density gradient in its vicinity. This change occurs under the action of ambipolar electric field, that is excited due to the increase of radial electron transport in magnetic islands

  18. Comparison of the sagittal sinus cross-sectional area between patients with multiple sclerosis, hydrocephalus, intracranial hypertension and spontaneous intracranial hypotension: a surrogate marker of venous transmural pressure?

    Science.gov (United States)

    Bateman, Grant A; Lechner-Scott, Jeannette; Copping, Ross; Moeskops, Christopher; Yap, Swee Leong

    2017-07-06

    There is evidence that patients with multiple sclerosis (MS) and hydrocephalus share some common pathophysiological mechanisms. Alterations in CSF pressure are known to affect cerebral venous sinus geometry. To further explore these mechanisms, we measured the superior sagittal sinus (SSS) cross-sectional area 3 cm above the torcular using T2 images in 20 MS, 10 spontaneous intracranial hypotension (SIH), 21 hydrocephalus and 20 idiopathic intracranial hypertension (IIH) patients and compared with 20 matched controls. The SSS area was reduced by 25% in hydrocephalus (p = 0.0008), increased by 22% (p = 0.037) in SIH and unchanged in IIH compared to matched controls. In MS there was a 16% increase in SSS area (p = 0.01).The findings suggest that changes in SSS cross-sectional are common between MS and SIH patients, while in hydrocephalus and IIH these are different.

  19. Size distribution of magnetic iron oxide nanoparticles using Warren-Averbach XRD analysis

    Science.gov (United States)

    Mahadevan, S.; Behera, S. P.; Gnanaprakash, G.; Jayakumar, T.; Philip, J.; Rao, B. P. C.

    2012-07-01

    We use the Fourier transform based Warren-Averbach (WA) analysis to separate the contributions of X-ray diffraction (XRD) profile broadening due to crystallite size and microstrain for magnetic iron oxide nanoparticles. The profile shape of the column length distribution, obtained from WA analysis, is used to analyze the shape of the magnetic iron oxide nanoparticles. From the column length distribution, the crystallite size and its distribution are estimated for these nanoparticles which are compared with size distribution obtained from dynamic light scattering measurements. The crystallite size and size distribution of crystallites obtained from WA analysis are explained based on the experimental parameters employed in preparation of these magnetic iron oxide nanoparticles. The variation of volume weighted diameter (Dv, from WA analysis) with saturation magnetization (Ms) fits well to a core shell model wherein it is known that Ms=Mbulk(1-6g/Dv) with Mbulk as bulk magnetization of iron oxide and g as magnetic shell disorder thickness.

  20. Screening for spontaneous preterm birth

    NARCIS (Netherlands)

    van Os, M.A.; van Dam, A.J.E.M.

    2015-01-01

    Preterm birth is the most important cause of perinatal morbidity and mortality worldwide. In this thesis studies on spontaneous preterm birth are presented. The main objective was to investigate the predictive capacity of mid-trimester cervical length measurement for spontaneous preterm birth in a

  1. A preliminary magnetic study of Sawa lake sediments, Southern Iraq

    Science.gov (United States)

    Ameen, Nawrass

    2016-04-01

    A preliminary magnetic study combined with chemical analyses was carried out in Sawa Lake in Al-Muthanna province, southern Iraq, about 22 km south west of Samawa city (31°18'48.80"N, 45°0'25.25"E). The lake is about 4.74 km length, 1.75 km width and 5.5 m height, it is surrounded by a salt rim which is higher than the lake water by about 2.8 m and sea water by about 18.5 m (Naqash et al., 1977 in Hassan, 2007). The lake is an elongated closed basin with no surface water available to it, it may be fed by groundwater of the Euphrates and Dammam aquifers through system of joints and cracks. This study aims to investigate the concentrations of selected heavy metals as pollutants and magnetic susceptibility (MS) and other magnetic properties of sediment samples from fifty sites collected from the bottom of the lake, the study area lies in an industrial area. The results show spatial variations of MS with mean value of about 4.58 x 10-8 m3 kg-1. Scanning electron microscopy and magnetic mineralogy parameters indicate the dominance of soft magnetic phase like magnetite and presence of hard magnetic phase like hematite. Spatial variations of MS combined with the concentrations of heavy metals suggests the efficiency of magnetic methods as effective, inexpensive and non-time consuming method to outlining the heavy metal pollution. References: Hassan W.F., 2007. The Physio-chemical characteristic of Sawa lake water in Samawa city-Iraq. Marine Mesopotamica, 22(2), 167-179.

  2. Early pregnancy angiogenic markers and spontaneous abortion

    DEFF Research Database (Denmark)

    Andersen, Louise B; Dechend, Ralf; Karumanchi, S Ananth

    2016-01-01

    BACKGROUND: Spontaneous abortion is the most commonly observed adverse pregnancy outcome. The angiogenic factors soluble Fms-like kinase 1 and placental growth factor are critical for normal pregnancy and may be associated to spontaneous abortion. OBJECTIVE: We investigated the association between...... maternal serum concentrations of soluble Fms-like kinase 1 and placental growth factor, and subsequent spontaneous abortion. STUDY DESIGN: In the prospective observational Odense Child Cohort, 1676 pregnant women donated serum in early pregnancy, gestational week ..., interquartile range 71-103). Concentrations of soluble Fms-like kinase 1 and placental growth factor were determined with novel automated assays. Spontaneous abortion was defined as complete or incomplete spontaneous abortion, missed abortion, or blighted ovum

  3. DLVO and XDLVO calculations for bacteriophage MS2 adhesion to iron oxide particles.

    Science.gov (United States)

    Park, Jeong-Ann; Kim, Song-Bae

    2015-10-01

    In this study, batch experiments were performed to examine the adhesion of bacteriophage MS2 to three iron oxide particles (IOP1, IOP2 and IOP3) with different particle properties. The characteristics of MS2 and iron oxides were analyzed using various techniques to construct the classical DLVO and XDLVO potential energy profiles between MS2 and iron oxides. X-ray diffractometry peaks indicated that IOP1 was mainly composed of maghemite (γ-Fe2O3), but also contained some goethite (α-FeOOH). IOP2 was composed of hematite (α-Fe2O3) and IOP3 was composed of iron (Fe), magnetite (Fe3O4) and iron oxide (FeO). Transmission electron microscope images showed that the primary particle size of IOP1 (γ-Fe2O3) was 12.3±4.1nm. IOP2 and IOP3 had primary particle sizes of 167±35nm and 484±192nm, respectively. A surface angle analyzer demonstrated that water contact angles of IOP1, IOP2, IOP3 and MS2 were 44.83, 64.00, 34.33 and 33.00°, respectively. A vibrating sample magnetometer showed that the magnetic saturations of IOP1, IOP2 and IOP3 were 176.87, 17.02 and 946.85kA/m, respectively. Surface potentials measured in artificial ground water (AGW; 0.075mM CaCl2, 0.082mM MgCl2, 0.051mM KCl, and 1.5mM NaHCO3; pH7.6) indicated that iron oxides and MS2 were negatively charged in AGW (IOP1=-0.0185V; IOP2=-0.0194V; IOP3=-0.0301V; MS2=-0.0245V). Batch experiments demonstrated that MS2 adhesion to iron oxides was favorable in the order of IOP1>IOP2>IOP3. This tendency was well predicted by the classical DLVO model. In the DLVO calculations, both the sphere-plate and sphere-sphere geometries predicted the same trend of MS2 adhesion to iron oxides. Additionally, noticeable differences were not found between the DLVO and XDLVO interaction energy profiles, indicating that hydrophobic interactions did not play a major role; electrostatic interactions, however, did influence MS2 adhesion to iron oxides. Furthermore, the aggregation of iron oxides was investigated with a modified XDLVO

  4. A general perspective on the magnetization reversal in cylindrical soft magnetic nanowires with dominant shape anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Kuncser, A. [National Institute of Materials Physics, PO Box MG-7, 077125 Bucharest-Magurele (Romania); University of Bucharest, Faculty of Physics, PO Box MG-11, 077125 Bucharest-Magurele (Romania); Antohe, S. [University of Bucharest, Faculty of Physics, PO Box MG-11, 077125 Bucharest-Magurele (Romania); Kuncser, V., E-mail: kuncser@infim.ro [National Institute of Materials Physics, PO Box MG-7, 077125 Bucharest-Magurele (Romania)

    2017-02-01

    Peculiarities of the magnetization reversal process in cylindrical Ni-Cu soft magnetic nanowires with dominant shape anisotropy are analyzed via both static and time dependent micromagnetic simulations. A reversible process involving a coherent-like spin rotation is always observed for magnetic fields applied perpendicularly to the easy axis whereas nucleation of domain walls is introduced for fields applied along the easy axis. Simple criteria for making distinction between a Stoner-Wohlfarth type rotation and a nucleation mechanism in systems with uniaxial magnetic anisotropy are discussed. Superposed reversal mechanisms can be in action for magnetic fields applied at arbitrary angles with respect to the easy axis within the condition of an enough strong axial component required by the nucleation. The dynamics of the domain wall, involving two different stages (nucleation and propagation), is discussed with respect to initial computing conditions and orientations of the magnetic field. A nucleation time of about 3 ns and corkscrew domain walls propagating with a constant velocity of about 150 m/s are obtained in case of Ni-Cu alloy (Ni rich side) NWs with diameters of 40 nm and high aspect ratio. - Highlights: • The formation and the dynamics of the domain walls in magnetic nanowires have been studied by micromagnetic simulations. • Simple criteria for making distinction between Stoner-Wohlfarth type and nucleation mechanisms in nanowires were discussed. • Corkscrew domain walls or quasi-coherent spin rotation may be induced depending on the field orientation. • The nucleation time was estimated at 3 ns and the wall velocity at 150 m/s. • A simple way for tuning the wall velocity in such systems was mentioned.

  5. High-throughput fragment screening by affinity LC-MS.

    Science.gov (United States)

    Duong-Thi, Minh-Dao; Bergström, Maria; Fex, Tomas; Isaksson, Roland; Ohlson, Sten

    2013-02-01

    Fragment screening, an emerging approach for hit finding in drug discovery, has recently been proven effective by its first approved drug, vemurafenib, for cancer treatment. Techniques such as nuclear magnetic resonance, surface plasmon resonance, and isothemal titration calorimetry, with their own pros and cons, have been employed for screening fragment libraries. As an alternative approach, screening based on high-performance liquid chromatography separation has been developed. In this work, we present weak affinity LC/MS as a method to screen fragments under high-throughput conditions. Affinity-based capillary columns with immobilized thrombin were used to screen a collection of 590 compounds from a fragment library. The collection was divided into 11 mixtures (each containing 35 to 65 fragments) and screened by MS detection. The primary screening was performed in 3500 fragments per day). Thirty hits were defined, which subsequently entered a secondary screening using an active site-blocked thrombin column for confirmation of specificity. One hit showed selective binding to thrombin with an estimated dissociation constant (K (D)) in the 0.1 mM range. This study shows that affinity LC/MS is characterized by high throughput, ease of operation, and low consumption of target and fragments, and therefore it promises to be a valuable method for fragment screening.

  6. Spontaneous emission by moving atoms

    International Nuclear Information System (INIS)

    Meystre, P.; Wilkens, M.

    1994-01-01

    It is well known that spontaneous emission is not an intrinsic atomic property, but rather results from the coupling of the atom to the vacuum modes of the electromagnetic field. As such, it can be modified by tailoring the electromagnetic environment into which the atom can radiate. This was already realized by Purcell, who noted that the spontaneous emission rate can be enhanced if the atom placed inside a cavity is resonant with one of the cavity is resonant with one of the cavity modes, and by Kleppner, who discussed the opposite case of inhibited spontaneous emission. It has also been recognized that spontaneous emission need not be an irreversible process. Indeed, a system consisting of a single atom coupled to a single mode of the electromagnetic field undergoes a periodic exchange of excitation between the atom and the field. This periodic exchange remains dominant as long as the strength of the coupling between the atom and a cavity mode is itself dominant. 23 refs., 6 figs

  7. Magnetic properties and microstructure of as-spun Fe3B/Nd2Fe14B nanocomposite permanent magnets produced by low-speed melt spinning technique

    International Nuclear Information System (INIS)

    Hirosawa, S.; Kanekiyo, H.; Ping, D.H.; Hono, K.

    1998-01-01

    Thick permanent magnet flakes of Fe 3 B/Nd 2 Fe 14 B nanocomposites have been produced directly from molten alloys by means of the low surface-velocity melt spinning technique. The thickness of the flakes varies from 70 to 300 μm depending on the surface velocity (V s ) of a quenching copper roll. Melt-spun flakes of Nd 4 Fe 77.5 B 18.5 alloy exhibit the intrinsic coercivity of 276 kA/m at V s of 5 m/s. X-ray diffraction and transmission electron microscopy results have revealed that this material is composed of nanocrystalline Fe 3 B and Nd 2 Fe 14 B grains ranging from 10 to 50 nm in diameter. The melt-spun alloy produced at V s = 3 m/s contains large grains of Nd 2 Fe 14 B, small grains of Fe 3 B, and large dendritic α-Fe of a few μm in length. In contrast, at V s = 7 m/s, a large portion of the quenched alloy is amorphous. These melt-spun alloys do not possess a hard magnetic property. We have also found that small additions of additives affect the optimum range of V s that give rise to hard magnetic properties in the as-melt-spun condition. Cr has a large effect in shifting the optimum V s values down to a 2-3 m/s range. Simultaneous addition of Co and Ga is effective in extending the optimum values of V s . A platelet permanent magnet with a thickness of 240 μm and magnetic properties of (BH) max = 131 kJ/m 3 , H cJ = 400 kA/m, and B r = 1.15 T has been produced from a Nd 3.5 Dy 1 Fe 73 Co 3 Ga 1 B 18.5 alloy. (orig.)

  8. A Case of Multiple Spontaneous Keloid Scars

    Directory of Open Access Journals (Sweden)

    Abdulhadi Jfri

    2015-07-01

    Full Text Available Keloid scars result from an abnormal healing response to cutaneous injury or inflammation that extends beyond the borders of the original wound. Spontaneous keloid scars forming in the absence of any previous trauma or surgical procedure are rare. Certain syndromes have been associated with this phenomenon, and few reports have discussed the evidence of single spontaneous keloid scar, which raises the question whether they are really spontaneous. Here, we present a 27-year-old mentally retarded single female with orbital hypertelorism, broad nasal bridge, repaired cleft lip and high-arched palate who presented with progressive multiple spontaneous keloid scars in different parts of her body which were confirmed histologically by the presence of typical keloidal collagen. This report supports the fact that keloid scars can appear spontaneously and are possibly linked to a genetic factor. Furthermore, it describes a new presentation of spontaneous keloid scars in the form of multiple large lesions in different sites of the body.

  9. Ex vivo spontaneous generation of 19-norandrostenedione and nandrolone detected in equine plasma and urine.

    Science.gov (United States)

    Guan, Fuyu; Uboh, Cornelius E; Soma, Lawrence R; You, Youwen; Li, Xiaoqing; McDonnell, Sue

    2012-01-01

    19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts due to the analytical procedure. The present study was undertaken to determine whether NAED and nandrolone detected in plasma and urine samples collected from stallions are truly endogenous or artifacts from sample processing. To answer this question, fresh plasma and urine samples from ≥8 stallions were analyzed for the two AASs, soon after collection, by liquid chromatography hyphenated to tandem mass spectrometry (LC-MS/MS). NAED and nandrolone were not detected in fresh plasma samples but detected in the same samples post storage. Concentrations of both AASs increased with storage time, and the increases were greater at a higher storage temperature (37°C versus 4°C, and ambient temperature versus 4°C). Although NAED was detected in some fresh stallion urine samples, its concentration (samples post storage (at ambient temperature for 15 days). Nandrolone was not detected in most of fresh urine samples but detected in the same samples post storage. Based on these results, it is concluded that all NAED and nandrolone detected in stored plasma samples of stallions and most of them in the stored urine samples are not from endogenous origins but spontaneously generated during sample storage, most likely from spontaneous decarboxylation of androstenedione-19-oic acid and testosterone-19-oic acid. To our knowledge, it is the first time that all NAED and nandrolone detected in

  10. Analysis of poly-beta-hydroxybutyrate in environmental samples by GC-MS/MS.

    Science.gov (United States)

    Elhottová, D; Tríska, J; Petersen, S O; Santrůcková, H

    2000-05-01

    Application of gas chromatography-mass spectrometry (GC-MS) can significantly improve trace analyses of compounds in complex matrices from natural environments compared to gas chromatography only. A GC-MS/MS technique for determination of poly-beta-hydroxybutyrate (PHB), a bacterial storage compound, has been developed and used for analysis of two soils stored for up to 319 d, fresh samples of sewage sludge, as well as a pure culture of Bacillus megaterium. Specific derivatization of beta-hydroxybutyrate (3-OH C4:0) PHB monomer units by N-tert-butyl-dimethylsilyl-N-methyltrifluoracetamide (MTBSTFA) improved chromatographic and mass spectrometric properties of the analyte. The diagnostic fragmentation scheme of the derivates tert-butyldimethylsilyl ester and ether of beta-hydroxybutyric acid (MTBSTFA-HB) essential for the PHB identification was shown. The ion trap MS was used, therefore the scan gave the best sensitivity and with MS/MS the noise decreased, so the S/N was better and also with second fragmentation the amount of ions increased compared to SIM. The detection limit for MTBSTFA-HB by GC-MS/MS was about 10(-13) g microL(-1) of injected volume, while by GC (FID) and GC-MS (scan) it was around 10(-10) g microL(-1) of injected volume. Sensitivity of GC-MS/MS measurements of PHB in arable soil and activated sludge samples was down to 10 pg of PHB g(-1) dry matter. Comparison of MTBSTFA-HB detection in natural soil sample by GC (FID), GC-MS (scan) and by GC-MS/MS demonstrated potentials and limitations of the individual measurement techniques.

  11. Experimental investigation of the trigger problem in magnetic reconnection

    International Nuclear Information System (INIS)

    Katz, Noam; Egedal, Jan; Fox, Will; Le, Ari; Vrublevskis, Arturs; Bonde, Jeff

    2011-01-01

    Magnetic reconnection releases magnetic energy not only in steady state, but also in time-dependent and often explosive events. Here, we investigate the trigger mechanism for this explosive release by using a toroidal experiment in the strong guide-field regime. We observe spontaneous reconnection events with exponentially growing reconnection rates, and we characterize the full 3D dynamics of these events using multiple internal probes. The reconnection is asymmetric: it begins at one toroidal location and propagates around in both directions. The spontaneous onset is facilitated by an interaction between the x-line current channel and a global mode, which appears in the electrostatic potential. It is this mode which breaks axisymmetry and enables a localized decrease in x-line current. We apply a simple model - which relies on ion polarization currents for current continuity - to reproduce the exponential growth and compute the growth rate. The result agrees well with the experimental growth rate.

  12. Ferroelectricity by Bose-Einstein condensation in a quantum magnet.

    Science.gov (United States)

    Kimura, S; Kakihata, K; Sawada, Y; Watanabe, K; Matsumoto, M; Hagiwara, M; Tanaka, H

    2016-09-26

    The Bose-Einstein condensation is a fascinating phenomenon, which results from quantum statistics for identical particles with an integer spin. Surprising properties, such as superfluidity, vortex quantization or Josephson effect, appear owing to the macroscopic quantum coherence, which spontaneously develops in Bose-Einstein condensates. Realization of Bose-Einstein condensation is not restricted in fluids like liquid helium, a superconducting phase of paired electrons in a metal and laser-cooled dilute alkali atoms. Bosonic quasi-particles like exciton-polariton and magnon in solids-state systems can also undergo Bose-Einstein condensation in certain conditions. Here, we report that the quantum coherence in Bose-Einstein condensate of the magnon quasi particles yields spontaneous electric polarization in the quantum magnet TlCuCl 3 , leading to remarkable magnetoelectric effect. Very soft ferroelectricity is realized as a consequence of the O(2) symmetry breaking by magnon Bose-Einstein condensation. The finding of this ferroelectricity will open a new window to explore multi-functionality of quantum magnets.

  13. Advanced functional materials in solid phase extraction for ICP-MS determination of trace elements and their species - A review.

    Science.gov (United States)

    He, Man; Huang, Lijin; Zhao, Bingshan; Chen, Beibei; Hu, Bin

    2017-06-22

    For the determination of trace elements and their species in various real samples by inductively coupled plasma mass spectrometry (ICP-MS), solid phase extraction (SPE) is a commonly used sample pretreatment technique to remove complex matrix, pre-concentrate target analytes and make the samples suitable for subsequent sample introduction and measurements. The sensitivity, selectivity/anti-interference ability, sample throughput and application potential of the methodology of SPE-ICP-MS are greatly dependent on SPE adsorbents. This article presents a general overview of the use of advanced functional materials (AFMs) in SPE for ICP-MS determination of trace elements and their species in the past decade. Herein the AFMs refer to the materials featuring with high adsorption capacity, good selectivity, fast adsorption/desorption dynamics and satisfying special requirements in real sample analysis, including nanometer-sized materials, porous materials, ion imprinting polymers, restricted access materials and magnetic materials. Carbon/silica/metal/metal oxide nanometer-sized adsorbents with high surface area and plenty of adsorption sites exhibit high adsorption capacity, and porous adsorbents would provide more adsorption sites and faster adsorption dynamics. The selectivity of the materials for target elements/species can be improved by using physical/chemical modification, ion imprinting and restricted accessed technique. Magnetic adsorbents in conventional batch operation offer unique magnetic response and high surface area-volume ratio which provide a very easy phase separation, greater extraction capacity and efficiency over conventional adsorbents, and chip-based magnetic SPE provides a versatile platform for special requirement (e.g. cell analysis). The performance of these adsorbents for the determination of trace elements and their species in different matrices by ICP-MS is discussed in detail, along with perspectives and possible challenges in the future

  14. An integrated rock magnetic and EPR study in soil samples from a hydrocarbon prospective area

    Science.gov (United States)

    González, F.; Aldana, M.; Costanzo-Álvarez, V.; Díaz, M.; Romero, I.

    Magnetic susceptibility (MS) and organic matter free radical concentration (OMFRC) determined by electron paramagnetic resonance, have been measured in soil samples (≈1.5 m depth) from an oil prospective area located at the southern flank of the Venezuelan Andean Range. S-ratios close to 1, as well as high temperature susceptibility analyses, reveal magnetite as the chief magnetic phase in most of these samples. Ethane concentrations, MS and OMFRC normalized data have been plotted against the relative position of 22 sampling sites sequentially arranged from north to south. Although there is not a linear correlation between MS and OMFRC data, these two profiles seem to vary in like fashion. A MS and OMFRC southern anomaly coincides with the zone of highest ethane concentration that overlies a “Cretaceous kitchen”. OMFRC highs could be linked to the degradation or alteration of organic matter, the possible result of hydrocarbon gas leakage, whose surface expression is the stressed fern observed by remote sensing studies previously performed in the area. Ethane anomalies are associated to this seepage that also produces changes in the magnetic mineralogies detected as MS positive anomalies.

  15. Magnetic Susceptibility and Heavy Metals in Guano from South Sulawesi Caves

    Science.gov (United States)

    Rifai, H.; Putra, R.; Fadila, M. R.; Erni, E.; Wurster, C. M.

    2018-04-01

    Measurement of some magnetic properties have been performed on vertical profile from South Sulawesi caves (Mampu and Bubau) by using low cost, rapid, sensitive and non destructive magnetic method. The aim is to attempt to use magnetic characters as a fingerprint for anthropogenic pollution in the caves. Guano samples were collected every 5 cm at a certain section of Mampu and Bubau cave, South Sulawesi, starting from surface through 300 cm in depth of mampu Cave and 30 cm of Bubau Cave. The magnetic parameters such as magnetic susceptibility and percentage frequency dependence susceptibility were measured using the Bartington MS2-MS2B instruments and supported by X-Ray Fluoroscence (XRF) to know their element composition. The results show that the samples had variations in magnetic susceptibility from 3.5 to 242.6 x 10‑8 m3/kg for Mampu Cave and from 8.6 to 106.5 x 10‑8 m3/kg for Bubau Cave and also magnetic domain. Then, the XRF results show that the caves contain several heavy metals. Magnetic and heavy metal analyses showing that the magnetic minerals in caves are lithogenic (Fe-bearing minerals) in origin and anthropogenic (Zn content) in the caves.

  16. 3D imaging of magnetic particles using the 7-channel magnetoencephalography device without pre-magnetization or displacement of the sample

    Energy Technology Data Exchange (ETDEWEB)

    Polikarpov, M.A., E-mail: polikarpov_imp@mail.ru [National Research Center “Kurchatov Institute”, Moscow (Russian Federation); Ustinin, M.N.; Rykunov, S.D. [Institute of Mathematical Problems of Biology, Russian Academy of Sciences, Pushchino (Russian Federation); Yurenya, A.Y. [National Research Center “Kurchatov Institute”, Moscow (Russian Federation); Faculty of Physics, Lomonosov Moscow State University, Moscow (Russian Federation); Naurzakov, S.P.; Grebenkin, A.P. [National Research Center “Kurchatov Institute”, Moscow (Russian Federation); Panchenko, V.Y. [National Research Center “Kurchatov Institute”, Moscow (Russian Federation); Faculty of Physics, Lomonosov Moscow State University, Moscow (Russian Federation)

    2017-04-01

    SQUID-based magnetoencephalography device was used for the measurement of a magnetic noise generated by ferrofluid in the stationary standing vial. It was found that a free surface of the ferrofluid generates spontaneous magnetic field sufficient to detect the presence of nanoparticles in the experimental setup. The spatial distribution of elementary magnetic sources was reconstructed by the frequency-pattern analysis of multichannel time series. The localization of ferrofluids was performed based on the analysis of quasirandom time series in two cases of oscillation source. One of them was infrasound from outer noise, and another one was the human heartbeat. These results are prospective for 3D imaging of magnetic particles without pre-magnetization. - Highlights: • A new method of imaging of magnetic nanoparticles in human body is proposed. • The method uses quasi-random fluctuations of the particles in geomagnetic field. • The use of heartbeats as a source of such fluctuations is demonstrated.

  17. Spontaneous pneumothorax in silicotuberculosis of lung

    International Nuclear Information System (INIS)

    Kolenic, J.; Jurgova, T.; Zimacek, J.; Vajo, J.; Krchnavy, M.

    1995-01-01

    The authors describe the case of 62 years old man with the appearance of spontaneous pneumothorax, in whom the basic pulmonary disease was silicotuberculosis of the lung. At clinic of occupational diseases in Kosice have been evidence 965 cases of silicosis and silicotuberculosis. From 1971 they have now the first case of spontaneous pneumothorax. The authors make discussion about possible mechanical and biochemical factors, which cause relatively low incidence of spontaneous pneumothorax in silicosis of the lung. (authors)

  18. Chiral soliton lattice and charged pion condensation in strong magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Brauner, Tomáš [Faculty of Science and Technology, University of Stavanger,N-4036 Stavanger (Norway); Yamamoto, Naoki [Department of Physics, Keio University,Yokohama 223-8522 (Japan)

    2017-04-21

    The Chiral Soliton Lattice (CSL) is a state with a periodic array of topological solitons that spontaneously breaks parity and translational symmetries. Such a state is known to appear in chiral magnets. We show that CSL also appears as a ground state of quantum chromodynamics at nonzero chemical potential in a magnetic field. By analyzing the fluctuations of the CSL, we furthermore demonstrate that in strong but achievable magnetic fields, charged pions undergo Bose-Einstein condensation. Our results, based on a systematic low-energy effective theory, are model-independent and fully analytic.

  19. Magnetic bubbles and domain evolution in Fe/Gd multilayer nanodots

    Science.gov (United States)

    Wang, T. T.; Liu, W.; Dai, Z. M.; Zhao, X. T.; Zhao, X. G.; Zhang, Z. D.

    2018-04-01

    The formation of magnetic bubbles and the domain-evolution processes, induced by a perpendicular magnetic field in Fe/Gd multilayer films and nanodots, have been investigated. At room temperature, the stripe domains in a continuous film transform into magnetic bubbles in an external field, while bubbles form spontaneously in nanodots due to the existence of shape anisotropy. When the temperature decreases to 20 K, the enhancement of the perpendicular magnetic anisotropy of the samples results in an increase of the domain size in the continuous film and the magnetization-reversal behavior of each nanodot becomes independent, and most reversed dots do not depend on each other, indicating the magnetic characteristics of a single domain. The present research provides further understanding of the evolution of magnetic bubbles in the Fe/Gd system and suggests their promising applications in patterned recording materials.

  20. Synchronized multiple regression of diagnostic radiation-induced rather than spontaneous: disseminated primary intracranial germinoma in a woman: a case report

    Directory of Open Access Journals (Sweden)

    Natsumeda Manabu

    2011-01-01

    Full Text Available Abstract Introduction Examples of the spontaneous regression of primary intracranial germinomas can be found in the literature. We present the case of a patient with disseminated lesions of primary intracranial germinoma which synchronously shrunk following diagnostic irradiation. We will discuss whether this regression was spontaneous or radiation-induced. Case presentation A 43-year-old Japanese woman presented to our hospital complaining of memory problems over a period of one year and blurred vision over a period of three months. Following magnetic resonance imaging, she was found to have a massive lesion in the third ventricle and small lesions in the pineal region, fourth ventricle, and in the anterior horn of the left lateral ventricle. Prior to an open biopsy to confirm the pathology of the lesions, she underwent a single cranial computed tomography scan and a single cranial digital subtraction angiography for a transcranial biopsy. Fourteen days after the first magnetic resonance image - 12 and eight days after the computed tomography scan and digital subtraction angiography, respectively - a pre-operative magnetic resonance image was taken, which showed a notable synchronous shrinkage of the third ventricle tumor, as well as shrinkage of the lesions in the pineal region and in the fourth ventricle. She did not undergo steroid administration until after a biopsy that confirmed the pathological diagnosis of pure germinoma. She then underwent whole craniospinal irradiation and went into a complete remission. Conclusions In our case report, we state that diagnostic radiation can induce the regression of germinomas; this is the most reasonable explanation for the synchronous multiple regression observed in this case of germinoma. Clinicians should keep this non-spontaneous regression in mind and monitor germinoma lesions with minimal exposure to diagnostic radiation before diagnostic confirmation, and also before radiation treatment with or

  1. Spontaneous body movements in spatial cognition

    Directory of Open Access Journals (Sweden)

    Sergiu eTcaci Popescu

    2012-05-01

    Full Text Available People often perform spontaneous body movements during spatial tasks such as giving complex directions or orienting themselves on maps. How are these spontaneous gestures related to spatial problem-solving? We measured spontaneous movements during a perspective-taking task inspired by map reading. Analyzing the motion data to isolate rotation and translation components of motion in specific geometric relation to the task, we found out that most participants executed spontaneous miniature rotations of the head that were significantly related to the main task parameter. These head rotations were as if participants were trying to align themselves with the orientation on the map either in the image plane or on the ground plane, but with tiny amplitudes, typically below 1% of the actual movements. Our results are consistent with a model of sensorimotor prediction driving spatial reasoning. The efference copy of planned movements triggers this prediction mechanism. The movements themselves may then be mostly inhibited; the small spontaneous gestures that we measure are the visible traces of these planned but inhibited actions.

  2. Spontaneous pneumothorax in diffuse cystic lung diseases.

    Science.gov (United States)

    Cooley, Joseph; Lee, Yun Chor Gary; Gupta, Nishant

    2017-07-01

    Diffuse cystic lung diseases (DCLDs) are a heterogeneous group of disorders with varying pathophysiologic mechanisms that are characterized by the presence of air-filled lung cysts. These cysts are prone to rupture, leading to the development of recurrent spontaneous pneumothoraces. In this article, we review the epidemiology, clinical features, and management DCLD-associated spontaneous pneumothorax, with a focus on lymphangioleiomyomatosis, Birt-Hogg-Dubé syndrome, and pulmonary Langerhans cell histiocytosis. DCLDs are responsible for approximately 10% of apparent primary spontaneous pneumothoraces. Computed tomography screening for DCLDs (Birt-Hogg-Dubé syndrome, lymphangioleiomyomatosis, and pulmonary Langerhans cell histiocytosis) following the first spontaneous pneumothorax has recently been shown to be cost-effective and can help facilitate early diagnosis of the underlying disorders. Patients with DCLD-associated spontaneous pneumothorax have a very high rate of recurrence, and thus pleurodesis should be considered following the first episode of spontaneous pneumothorax in these patients, rather than waiting for a recurrent episode. Prior pleurodesis is not a contraindication to future lung transplant. Although DCLDs are uncommon, spontaneous pneumothorax is often the sentinel event that provides an opportunity for diagnosis. By understanding the burden and implications of pneumothoraces in DCLDs, clinicians can facilitate early diagnosis and appropriate management of the underlying disorders.

  3. Spontaneous disappearance of two asymptomatic arachnoid cysts in two different locations.

    Science.gov (United States)

    Cokluk, C; Senel, A; Celik, F; Ergür, H

    2003-04-01

    We report two children with asymptomatic arachnoid cysts which resolved spontaneously without any surgical intervention and history of major head and body trauma. The first child was a 10-year-old boy with an arachnoid cyst in the right sylvian fissure. The second child was a 1-year-old girl with a right cerebral convexity arachnoid cyst. Both of them were asymptomatic. Arachnoid cysts spontaneously disappeared within 2 years following initial diagnosing. There was no major head and body trauma except usual home, school and sports activity. We speculated that the cysts ruptured into cerebrospinal fluid circulation by the mechanical effects of some forced activities to the brain tissue and cyst, such as excessive breathing, coughing and sport activities. These factors may change the balance between intracystic and pericystic pressure and facilitate the rupturing of the cyst into subdural, subarachnoid and intraventricular spaces. These cases demonstrate that neurosurgical intervention of asymptomatic arachnoid cysts is not absolutely indicated in the paediatric age group. Close follow up with computerized tomography (CT) and magnetic resonance imaging (MRI) is a treatment option in the patient with arachnoid cysts located in the middle cranial fossa and cerebral convexity.

  4. Analysis of the extracts of Isatis tinctoria by new analytical approaches of HPLC, MS and NMR.

    Science.gov (United States)

    Zhou, Jue; Qu, Fan

    2011-01-01

    The methods of extraction, separation and analysis of alkaloids and indole glucosinolates (GLs) ofIsatis tinctoria were reviewed. Different analytical approaches such as High-pressure Liquid Chromatography (HPLC), Liquid Chromatography with Electrospray Ionization Mass Spectrometry (LC/ESI/MS), Electrospray Ionization Time-Of-Flight Mass Spectrometry (ESI-TOF-MS), and Nuclear Magnetic Resonance (NMR) were used to validate and identity of these constituents. These methods provide rapid separation, identification and quantitative measurements of alkaloids and GLs of Isatis tinctoria. By connection with different detectors to HPLC such as PDA, ELSD, ESI- and APCI-MS in positive and negative ion modes, complicated compounds could be detected with at least two independent detection modes. The molecular formula can be derived in a second step of ESI-TOF-MS data. But for some constituents, UV and MS cannot provide sufficient structure identification. After peak purification, NMR by semi-preparative HPLC can be used as a complementary method.

  5. FEL gain optimisation and spontaneous radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bali, L.M.; Srivastava, A.; Pandya, T.P. [Lucknow Univ. (India)] [and others

    1995-12-31

    Colson have evaluated FEL gains for small deviations from perfect electron beam injection, with radiation of the same polarisation as that of the wiggler fields. We find that for optimum gain the polarisation of the optical field should be the same as that of the spontaneous emission under these conditions. With a helical wiggler the axial oscillations resulting from small departures from perfect electron beam injection lead to injection dependent unequal amplitudes and phases of the spontaneous radiation in the two transverse directions. Viewed along the axis therefore the spontaneous emission is elliptically polarised. The azimuth of the ellipse varies with the difference of phase of the two transverse components of spontaneous emission but the eccentricity remains the same. With planar wigglers the spontaneous emission viewed in the axial direction is linearly polarised, again with an injection dependent azimuth. For optimum coherent gain of a radiation field its polarisation characteristics must be the same as those of the spontaneous radiation with both types of wiggler. Thus, with a helical wiggler and the data reported earlier, an increase of 10% in the FEL gain at the fundamental frequency and of 11% at the fifth harmonic has been calculated in the small gain per pass limit. Larger enhancements in gain may result from more favourable values of input parameters.

  6. A simple model for localized-itinerant magnetic systems: crystal field effects

    International Nuclear Information System (INIS)

    Iannarella, L.; Silva, X.A. da; Guimarares, A.P.

    1989-01-01

    The magnetic behavior of a system consisting of localized electrons coupled to conduction electrons and submitted to an axial crystral field at T=0 K is ivestigated within the framework of the molecular field approximation. An analytical ionic magnetic state equation is deduced; it shows how the magnetization depends on the model parameters (exchange, crystal field, band occupation) and external magnetic field. A condition for the onset of spontaneous magnetic order is obtained and the ferro - and paramagnetic phases are studied. This study displays several features of real magnetic systems, including quenching or total suppression of the magnetic moments (depending on the relative value of the crystal field parameter) and exchange enhacement. The relevance of such model for the description of rare-earth intermetallic compounds is discussed. (author) [pt

  7. Cannabinoids determination in oral fluid by SPME-GC/MS and UHPLC-MS/MS and its application on suspected drivers.

    Science.gov (United States)

    Anzillotti, Luca; Castrignanò, Erika; Strano Rossi, Sabina; Chiarotti, Marcello

    2014-12-01

    The confirmation of Δ9-tetrahydrocannabinol (THC) in oral fluid (OF) is an important issue for assessing Driving Under the Influence of Drugs (DUID). The aim of this research was to develop a highly sensitive method with minimal sample pre-treatment suitable for the analysis of small OF volumes (100 μL) for the confirmation of cannabinoids in DUID cases. Two methods were compared for the confirmation of THC in residual OF samples, obtained from a preliminary on-site screening with commercial devices. An ultra high performance LC-MS (UHPLC-MS/MS) method and an SPME-GC/MS method were hence developed. 100 μL of the residual mixture OF/preservative buffer or neat OF was simply added to 10 μL of THC-D3 (1 μg/mL) and submitted to the two different analyses: A - direct injection of 10 μL in UHPLC-MS/MS in positive electrospray ionisation (ESI) mode and B - sampling for 30 min with SPME (100 μm polydimethylsiloxane or PDMS fibre) and direct injection by desorption of the fibre in the GC injection port. The lowest limit of detection (LLOD) of THC was 2 ng/mL in UHPLC-MS/MS and 0.5 ng/mL in SPME-GC/MS. In addition, cannabidiol (CBD) and cannabinol (CBN) could be detected in GC/MS equipment at 2 ng/mL, whilst in UHPLC-MS/MS the LLOD was 20 ng/mL. Both methods were applied to 70 samples coming from roadside tests. By SPME-GC/MS analysis, THC was confirmed in 42 samples, whilst CBD was detected in 21 of them, along with CBN in 14 samples. THC concentrations ranged from traces below the lowest limit of quantification or LLOQ (2 ng/mL) up to 690 ng/mL. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.

  8. Software ion scan functions in analysis of glycomic and lipidomic MS/MS datasets.

    Science.gov (United States)

    Haramija, Marko

    2018-03-01

    Hardware ion scan functions unique to tandem mass spectrometry (MS/MS) mode of data acquisition, such as precursor ion scan (PIS) and neutral loss scan (NLS), are important for selective extraction of key structural data from complex MS/MS spectra. However, their software counterparts, software ion scan (SIS) functions, are still not regularly available. Software ion scan functions can be easily coded for additional functionalities, such as software multiple precursor ion scan, software no ion scan, and software variable ion scan functions. These are often necessary, since they allow more efficient analysis of complex MS/MS datasets, often encountered in glycomics and lipidomics. Software ion scan functions can be easily coded by using modern script languages and can be independent of instrument manufacturer. Here we demonstrate the utility of SIS functions on a medium-size glycomic MS/MS dataset. Knowledge of sample properties, as well as of diagnostic and conditional diagnostic ions crucial for data analysis, was needed. Based on the tables constructed with the output data from the SIS functions performed, a detailed analysis of a complex MS/MS glycomic dataset could be carried out in a quick, accurate, and efficient manner. Glycomic research is progressing slowly, and with respect to the MS experiments, one of the key obstacles for moving forward is the lack of appropriate bioinformatic tools necessary for fast analysis of glycomic MS/MS datasets. Adding novel SIS functionalities to the glycomic MS/MS toolbox has a potential to significantly speed up the glycomic data analysis process. Similar tools are useful for analysis of lipidomic MS/MS datasets as well, as will be discussed briefly. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Winds in the high-latitude lower thermosphere: Dependence on the interplanetary magnetic field

    DEFF Research Database (Denmark)

    Richmond, A.D.; Lathuillere, C.; Vennerstrøm, Susanne

    2003-01-01

    -side cyclonic vortex that responds more strongly to B-z variations. The dependence of the wind on the IMF is nonlinear, especially with respect to IMF B-z. For positive B-z the difference winds are largely confined to the polar cap, while for negative B-z the difference winds extend to subauroral latitudes...... of similar to20 hours, a B-y-dependent magnetic-zonal-mean zonal wind generally exists, with maximum wind speeds at 80 magnetic latitude, typically 10 m/s at 105 km, increasing to about 60 m/s at 123 km and 80 m/s at 200 km. In the southern hemisphere the wind is cyclonic when the time-averaged B...

  10. Rational synthesis of zerovalent iron/bamboo charcoal composites with high saturation magnetization

    Science.gov (United States)

    Mingshan Wu; Jianfeng Ma; Zhiyong Cai; Genlin Tian; Shumin Yang; Youhong Wang; Xing' e Liu

    2015-01-01

    The synthesis of magnetic biochar composites is a major new research area in advanced materials sciences. A series of magnetic bamboo charcoal composites (MBC800, MBC1000 and MBC1200) with high saturation magnetization (Ms) was fabricated in this work by mixing bamboo charcoal powder with an aqueous ferric chloride solution and subsequently...

  11. Spontaneous Bacterial Peritonitis in Subclinical Hypothyroidism

    Directory of Open Access Journals (Sweden)

    Dalip Gupta

    2013-11-01

    Full Text Available Hypothyroidism is an uncommon cause of ascites. Here we describe a case of a 75 year-old female patient with spontaneous bacterial peritonitis and subclinical hypothyroidism that resolved with thyroid replacement and antibiotic therapy respectively. Ascitic fluid analysis revealed a gram-positive bacterium on gram staining. A review of the literature revealed just one other reported case of myxoedema ascites with concomitant spontaneous bacterial peritonitis and no case has till been reported of spontaneous bacterial peritonitis in subclinical hypothyroidism.

  12. Spontaneous mutation rates and the rate-doubling dose

    International Nuclear Information System (INIS)

    Von Borstel, R.C.; Moustaccki, E.; Latarjet, R.

    1978-01-01

    The amount of radiation required to double the frequency of mutations or tumours over the rate of those that occur spontaneously is called the rate-doubling dose. An equivalent concept has been proposed for exposure to other environmental mutagens. The doubling dose concept is predicated on the assumption that all human populations have the same spontaneous mutation rate, and that this spontaneous mutation rate is known. It is now established for prokaryotes and lower eukaryotes that numerous genes control the spontaneous mutation rate, and it is likely that the same is true for human cells as well. Given that the accepted mode of evolution of human populatons is from small, isolated groups of individuals, it seems likely that each population would have a different spontaneous mutation rate. Given that a minimum of twenty genes control or affect the spontaneous mutation rate, and that each of these in turn is susceptible to spontaneously arising or environmentally induced mutations, it seems likely that every individual within a population (except for siblings from identical multiple births) will have a unique spontaneous mutation rate. If each individual in a population does have a different spontaneous mutation rate, the doubling dose concept, in rigorous terms, is fallacious. Therefore, as with other concepts of risk evaluation, the doubling dose concept is subject to criticism. Nevertheless, until we know individual spontaneous mutation rates with precision, and can evaluate risks based on this information, the doubling dose concept has a heuristic value and is needed for practical assessment of risks for defined populations. (author)

  13. On the role of topological complexity in spontaneous development of current sheets

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sanjay; Bhattacharyya, R. [Udaipur Solar Observatory, Physical Research Laboratory, Dewali, Bari Road, Udaipur-313001 (India); Smolarkiewicz, P. K. [European Centre for Medium-Range Weather Forecasts, Reading RG2 9AX (United Kingdom)

    2015-08-15

    The computations presented in this work aim to asses the importance of field line interlacing on spontaneous development of current sheets. From Parker's magnetostatic theorem, such development of current sheets is inevitable in a topologically complex magnetofluid, with infinite electrical conductivity, at equilibrium. Relevant initial value problems are constructed by superposition of two untwisted component fields, each component field being represented by a pair of global magnetic flux surface. The intensity of field line interlacing is then specified by the relative amplitude of the two superposed fields. The computations are performed by varying this relative amplitude. Also to have a direct visualization of current sheet formation, we follow the evolution of flux surfaces instead of the vector magnetic field. An important finding of this paper is in the demonstration that initial field lines having intense interlacing tend to develop current sheets which are distributed throughout the computational domain with no preference for topologically favorable sites like magnetic nulls or field reversal layers. The onsets of these current sheets are attributed to favorable contortions of magnetic flux surfaces where two oppositely directed parts of the same field line or different field lines come to close proximity. However, for less intensely interlaced field lines, the simulations indicate development of current sheets at sites only where the magnetic topology is favorable. These current sheets originate as two sets of anti-parallel complimentary field lines press onto each other.

  14. Arachnoid Pit and Extensive Sinus Pnematization as the Cause of Spontaneous Lateral Intrasphenoidal Encephalocele

    Directory of Open Access Journals (Sweden)

    Ali AlMontasheri

    2012-01-01

    Full Text Available Lateral sphenoid encephalocele, especially within the lateral aspect of the sphenoid sinus, when the sphenoid sinus has pneumatized extensively into the pterygoid recess, are considered exceedingly rare. We report a rare case of lateral intrasphenoidal encephalocele with spontaneous cerebral spinal fluid (CSF rhinorrhea. Computed tomography demonstrated bilateral arachnoid pit, extensive sphenoid sinus pneumatization, and a defect in the superior wall of the left lateral recess of the sphenoid sinus. Magnetic resonance imaging demonstrated anteromedial temporal lobe herniating through the bony defect.

  15. MODELING OF EQUIVALENT STIFFNESS OF A MAGNETIC SPRING OF VIBRATION EXCITER BASED ON COAXIAL-LINEAR MOTOR

    Directory of Open Access Journals (Sweden)

    G.M. Golenkov

    2015-12-01

    Full Text Available Purpose. The research of the influence of value and direction of current on the equivalent spring magnetic force based on coaxial-linear motor (CLM – MS. Methodology. We carried out investigation of the equivalent harshness of magnetic spring with determination of electromechanical propulsion performance characteristics by the methods of computer modeling and experimental research of physical model of CLM – MS. The modeling of magnetic spring of CLM – MS is carried out by the finite-element method. The challenge is met as an axisymmetric challenge in cylindrical co-ordinates in magnetostatic approach. The experimental investigattion of the propulsion performance characteristics of magnetic spring is carried out on the test bench. Results. After the computer modeling and the experimental investigation of the electromechanical propulsion performance characteristics of magnetic spring the expressions of equivalent stiffness coefficient depending on the current in winding are obtained. The results of computer modeling are confirmed experimentally. Originality. The determination of equivalent stiffness coefficient of magnetic spring of vibration exciter based on coaxial-linear motor. Practical value. The obtained determination of equivalent stiffness coefficient of magnetic spring may be used in process of designing of vibration machines with devices for change of natural oscillation frequency.

  16. Analytical Method Details (MS): SE52_MS01 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available stem and Waters Q-Tof Premier UPLC-QTOF-MS ESI Negative The eluates (3 μl) were subsequently subjected to metabolome...DS column (LC-ESI-Q-Tof/MS, HPLC: Waters Acquity UPLC system; MS: Waters Q-Tof Premier). The metabolome...d (Matsuda et al., 2009c, 2010a). Briefly, the metabolome data were obtained in the negative ion mode (m/z 1... the complex nature of the metabolome data. To construct MS2T libraries, the extracts of five ecotypes were

  17. Electro-optic switching and dielectric spectroscopy studies of ferroelectric liquid crystals with low and high spontaneous polarization

    Czech Academy of Sciences Publication Activity Database

    Malik, P.; Raina, K.K.; Bubnov, Alexej; Choudhary, A.; Singh, R.

    Roč. 519, č. 3 ( 2010 ), 1052-1055 ISSN 0040-6090 R&D Projects: GA AV ČR IAA100100911; GA AV ČR(CZ) GA202/09/0047 Grant - others:RFASI(RU) 02.740.11.5166 Institutional research plan: CEZ:AV0Z10100520 Keywords : spontaneous polarization * ferroelectric liquid crystal * relaxation frequency * Goldstone mode Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.909, year: 2010

  18. Improved differentiation between MS and vascular brain lesions using FLAIR* at 7 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    Kilsdonk, Iris D.; Wattjes, Mike P.; Lopez-Soriano, Alexandra; Jong, Marcus C. de; Graaf, Wolter L. de; Conijn, Mandy M.A.; Barkhof, Frederik [VU University Medical Center, Department of Radiology, De Boelelaan 1118, HZ, Amsterdam (Netherlands); Kuijer, Joost P.A. [VU University Medical Center, Department of Physics and Medical Technology, Amsterdam (Netherlands); Polman, Chris H. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Luijten, Peter R. [University Medical Center, Department of Radiology, Utrecht (Netherlands); Geurts, Jeroen J.G. [VU University, Department of Anatomy and Neurosciences, Amsterdam (Netherlands); Geerlings, Mirjam I. [University Medical Center, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands)

    2014-04-15

    To investigate whether a new magnetic resonance image (MRI) technique called T2*-weighted fluid attenuation inversion recovery (FLAIR*) can differentiate between multiple sclerosis (MS) and vascular brain lesions, at 7 Tesla (T). We examined 16 MS patients and 16 age-matched patients with (risk factors for) vascular disease. 3D-FLAIR and T2*-weighted images were combined into FLAIR* images. Lesion type and intensity, perivascular orientation and presence of a hypointense rim were analysed. In total, 433 cerebral lesions were detected in MS patients versus 86 lesions in vascular patients. Lesions in MS patients were significantly more often orientated in a perivascular manner: 74 % vs. 47 % (P < 0.001). Ten MS lesions (2.3 %) were surrounded by a hypointense rim on FLAIR*, and 24 MS lesions (5.5 %) were hypointense on T2*. No lesions in vascular patients showed any rim or hypointensity. Specificity of differentiating MS from vascular lesions on 7-T FLAIR* increased when the presence of a central vessel was taken into account (from 63 % to 88 %), most obviously for deep white matter lesions (from 69 % to 94 %). High sensitivity remained (81 %). 7-T FLAIR* improves differentiation between MS and vascular lesions based on lesion location, perivascular orientation and presence of hypointense (rims around) lesions. circle A new MRI technique T2*-weighted fluid attenuation inversion recovery (FLAIR*) was investigated. circle FLAIR* at 7-T MRI combines FLAIR and T2* images into a single image. circle FLAIR* at 7 T does not require enhancement with contrast agents. (orig.)

  19. The emergence of complex behaviours in molecular magnetic materials.

    Science.gov (United States)

    Goss, Karin; Gatteschi, Dante; Bogani, Lapo

    2014-09-14

    Molecular magnetism is considered an area where magnetic phenomena that are usually difficult to demonstrate can emerge with particular clarity. Over the years, however, less understandable systems have appeared in the literature of molecular magnetic materials, in some cases showing features that hint at the spontaneous emergence of global structures out of local interactions. This ingredient is typical of a wider class of problems, called complex behaviours, where the theory of complexity is currently being developed. In this perspective we wish to focus our attention on these systems and the underlying problematic that they highlight. We particularly highlight the emergence of the signatures of complexity in several molecular magnetic systems, which may provide unexplored opportunities for physical and chemical investigations.

  20. Information-dependent acquisition-mediated LC-MS/MS screening procedure with semiquantitative potential.

    Science.gov (United States)

    Decaestecker, Tineke N; Vande Casteele, Sofie R; Wallemacq, Pierre E; Van Peteghem, Carlos H; Defore, Dieter L; Van Bocxlaer, Jan F

    2004-11-01

    The development of a LC-MS/MS general unknown screening procedure for toxicologically relevant substances in blood samples by means of information-dependent acquisition on a Q-TOF is reported. IDA is an artificial intelligence-based product ion scan mode providing automatic "on-the-fly" MS to MS/MS switching. By performing information-dependent scanning at two different fragmentation energies, two collision-induced dissociation product ion spectra for each of the detected compounds are generated. As such, information-rich MS/MS spectra are obtained from precursor ions not known beforehand. In addition, limitation of the MS/MS acquisition time to an acceptable minimum resulted in an almost instantaneous switch back to the MS mode. As such, this approach provided MS chromatograms that still could be of use for semiquantitative purposes. Since the switching intensity threshold, unequivocally related to the background noise, proved a critical parameter, the solid-phase extraction procedure, the liquid chromatographic conditions, and the mass spectrometric parameters all were optimized to the advantage of information-dependent acquisition. Finally, the screening procedure we developed was benchmarked, on one hand, qualitatively against the results obtained from traditional GUS approaches in a number of routine toxicological laboratories (20 samples) and, on the other hand, quantitatively with respect to its potential against established LC-MS/MS methods (7 samples). The procedure performed very well from a qualitative point of view; almost all of the drugs detected by the conventional techniques were identified, as well as additional drugs that were not previously reported. The procedure proved well-suited for an initial semiquantitative assessment, as is customary in, for example, forensic toxicology before accurate intoxication levels are determined using targeted analytical analyses.

  1. Age determination of vessel wall hematoma in spontaneous cervical artery dissection: A multi-sequence 3T Cardiovascular Magnetic resonance study

    Directory of Open Access Journals (Sweden)

    Habs Maximilian

    2011-11-01

    Full Text Available Abstract Background Previously proposed classifications for carotid plaque and cerebral parenchymal hemorrhages are used to estimate the age of hematoma according to its signal intensities on T1w and T2w MR images. Using these classifications, we systematically investigated the value of cardiovascular magnetic resonance (CMR in determining the age of vessel wall hematoma (VWH in patients with spontaneous cervical artery dissection (sCAD. Methods 35 consecutive patients (mean age 43.6 ± 9.8 years with sCAD received a cervical multi-sequence 3T CMR with fat-saturated black-blood T1w-, T2w- and TOF images. Age of sCAD was defined as time between onset of symptoms (stroke, TIA or Horner's syndrome and the CMR scan. VWH were categorized into hyperacute, acute, early subacute, late subacute and chronic based on their signal intensities on T1w- and T2w images. Results The mean age of sCAD was 2.0, 5.8, 15.7 and 58.7 days in patients with acute, early subacute, late subacute and chronic VWH as classified by CMR (p Conclusions Signal intensities of VWH in sCAD vary over time and multi-sequence CMR can help to determine the age of an arterial dissection. Furthermore, findings of this study suggest that the time course of carotid hematomas differs from that of cerebral hematomas.

  2. Spontaneous brain activity predicts learning ability of foreign sounds.

    Science.gov (United States)

    Ventura-Campos, Noelia; Sanjuán, Ana; González, Julio; Palomar-García, María-Ángeles; Rodríguez-Pujadas, Aina; Sebastián-Gallés, Núria; Deco, Gustavo; Ávila, César

    2013-05-29

    Can learning capacity of the human brain be predicted from initial spontaneous functional connectivity (FC) between brain areas involved in a task? We combined task-related functional magnetic resonance imaging (fMRI) and resting-state fMRI (rs-fMRI) before and after training with a Hindi dental-retroflex nonnative contrast. Previous fMRI results were replicated, demonstrating that this learning recruited the left insula/frontal operculum and the left superior parietal lobe, among other areas of the brain. Crucially, resting-state FC (rs-FC) between these two areas at pretraining predicted individual differences in learning outcomes after distributed (Experiment 1) and intensive training (Experiment 2). Furthermore, this rs-FC was reduced at posttraining, a change that may also account for learning. Finally, resting-state network analyses showed that the mechanism underlying this reduction of rs-FC was mainly a transfer in intrinsic activity of the left frontal operculum/anterior insula from the left frontoparietal network to the salience network. Thus, rs-FC may contribute to predict learning ability and to understand how learning modifies the functioning of the brain. The discovery of this correspondence between initial spontaneous brain activity in task-related areas and posttraining performance opens new avenues to find predictors of learning capacities in the brain using task-related fMRI and rs-fMRI combined.

  3. Altered spontaneous activity of posterior cingulate cortex and superior temporal gyrus are associated with a smoking cessation treatment outcome using varenicline revealed by regional homogeneity.

    Science.gov (United States)

    Wang, Chao; Shen, Zhujing; Huang, Peiyu; Qian, Wei; Yu, Xinfeng; Sun, Jianzhong; Yu, Hualiang; Yang, Yihong; Zhang, Minming

    2017-06-01

    Compared to nonsmokers, smokers exhibit a number of potentially important differences in regional brain function. However, little is known about the associations between the local spontaneous brain activity and smoking cessation treatment outcomes. In the present analysis, we aimed to evaluate whether the local features of spontaneous brain activity prior to the target quit date was associated with the smoking cessation outcomes. All the participants underwent magnetic resonance imaging scans and smoking-related behavioral assessments. After a 12-week treatment with varenicline, 23 smokers succeeded in quitting smoking and 32 failed. Smokers underwent functional magnetic resonance imaging (fMRI) scanning prior to an open label smoking cessation treatment trial. Regional homogeneity (ReHo) was used to measure spontaneous brain activity, and whole-brain voxel-wise comparisons of ReHo were performed to detect brain regions with altered spontaneous brain activity between relapser and quitter groups. After controlling for potentially confounding factors including years of education, years smoked, cigarettes smoked per day and FTND score as covariates, compared to quitters, relapsers displayed significantly decreased ReHo in bilateral posterior cingulate cortex (PCC), as well as increased ReHo in left superior temporal gyrus (STG). These preliminary results suggest that regional brain function variables may be promising predictors of smoking relapse. This study provided novel insights into the neurobiological mechanisms underlying smoking relapse. A deeper understanding of the neurobiological mechanisms associated with relapse may result in novel pharmacological and behavioral interventions.

  4. Detection of the pedogenic magnetic fraction in volcanic soils developed on basalts using frequency-dependent magnetic susceptibility: comparison of two instruments

    Science.gov (United States)

    Grison, Hana; Petrovsky, Eduard; Kapicka, Ales; Hanzlikova, Hana

    2017-05-01

    In studies of the magnetic properties of soils, the frequency-dependent magnetic susceptibility percentage (χFD%) is often used for the identification of ultrafine magnetically superparamagnetic/stable single-domain (SP/SSD) particles. This parameter is commonly used as an indicator for increased pedogenesis. In strongly magnetic soils, the SP/SSD magnetic signal (mostly bio-pedogenic) may be masked by lithological signals; making pedogenesis hard to detect. In this study, we compare results for the detection of ultrafine SP/SSD magnetic particles in andic soils using two instruments: a Bartington MS2B dual-frequency meter and an AGICO Kappabridge MFK1-FA. In particular, the study focuses on the effect of pedogenesis by investigating the relationship between specific soil magnetic and chemical properties (soil organic carbon and pHH2O). The values of χFD% obtained with the MS2B varied from 2.4 to 5.9 per cent, and mass-specific magnetic susceptibility (χLF) from 283 to 1688 × 10-8 m3 kg-1, while values of χFD% and χLF obtained with the MFK1-FA varied from 2.7 to 8.2 per cent and from 299 to 1859 × 10-8 m3 kg-1, respectively. Our results suggest that the detection of the SP/SSD magnetic fraction can be accomplished by comparing relative trends of χFD% along the soil profile. Moreover, the discrimination between bio-pedogenic and lithogenic magnetic contributions in the SP/SSD fraction is possible by comparing the χFD% and χLF data determined in the fine earth (<2 mm) and the coarse fraction (4-10 mm) samples down the soil profile.

  5. Low-energy cardioversion of spontaneous atrial fibrillation. Immediate and long-term results.

    Science.gov (United States)

    Lévy, S; Ricard, P; Gueunoun, M; Yapo, F; Trigano, J; Mansouri, C; Paganelli, F

    1997-07-01

    Recent studies have suggested that induced atrial fibrillation (AF) could be successfully terminated by using a two-catheter electrode system and low energy (energy cardioversion in spontaneous chronic and paroxysmal AF. Forty-two consecutive patients with spontaneous AF underwent low-energy electrical cardioversion. AF was chronic (> or = 1 month) with a mean duration of 9 +/- 19 months in 28 patients (group I) or paroxysmal with a history of recurrent attacks and a mean duration of the present episode of 7 +/- 16 days in 14 patients (group II). An underlying heart disease was present in 28 patients. A 3/3-ms biphasic shock was delivered between catheters positioned in the right atrium and the coronary sinus in 32 patients. In 10 patients, the left pulmonary artery branch was used. The catheters were connected to a custom external defibrillator. The shocks were synchronized to the R wave. Following a test shock of 60 V, the energy was increased in 40-V steps until a maximum of 400 V or restoration of sinus rhythm. Sinus rhythm was restored in 22 of the 28 patients (78%) of group I by using a mean leading-edge voltage of 297 +/- 57 V (mean energy 3.3 +/- 1.3 J) and in 11 of 14 patients (78%) of group II by using a mean leading-edge voltage of 223 +/- 41 V (mean energy, 1.8 +/- 0.7 J). The energy required for terminating chronic AF was significantly (P energy between two intracardiac catheters with an electrical field between the right and left atria and the protocol used is feasible in patients with persistent spontaneous AF. The technique is safe provided synchronization to the R wave is achieved. A low recurrence rate of AF was seen in patients in whom sinus rhythm was restored.

  6. Visually Evoked Spiking Evolves While Spontaneous Ongoing Dynamics Persist

    Science.gov (United States)

    Huys, Raoul; Jirsa, Viktor K.; Darokhan, Ziauddin; Valentiniene, Sonata; Roland, Per E.

    2016-01-01

    Neurons in the primary visual cortex spontaneously spike even when there are no visual stimuli. It is unknown whether the spiking evoked by visual stimuli is just a modification of the spontaneous ongoing cortical spiking dynamics or whether the spontaneous spiking state disappears and is replaced by evoked spiking. This study of laminar recordings of spontaneous spiking and visually evoked spiking of neurons in the ferret primary visual cortex shows that the spiking dynamics does not change: the spontaneous spiking as well as evoked spiking is controlled by a stable and persisting fixed point attractor. Its existence guarantees that evoked spiking return to the spontaneous state. However, the spontaneous ongoing spiking state and the visual evoked spiking states are qualitatively different and are separated by a threshold (separatrix). The functional advantage of this organization is that it avoids the need for a system reorganization following visual stimulation, and impedes the transition of spontaneous spiking to evoked spiking and the propagation of spontaneous spiking from layer 4 to layers 2–3. PMID:26778982

  7. Acute Abdomen Secondary to a Spontaneous Perforation of the Biliary Tract, a Rare Complication of Choledocholithiasis

    Directory of Open Access Journals (Sweden)

    G.A. Gómez-Torres

    Full Text Available Introduction: The spontaneous perforation of the biliary tract (SPBT is an extremely rare cause of peritonitis, which was first described by Freeland in 1982, to date only around 70 cases have been reported. Here we present a case of spontaneous perforation of the biliary tract, in a patient with choledocholithiasis, which was treated with ultrasound-guided drainage and ERCP. Case report: A 51-year-old male was admitted to the emergency room for 15-day evolution jaundice, localized pain in the right flank and hypochondrium of 3 days. He had a history of cholecystectomy 15 years ago and 4 episodes of cholangitis, the last one in 2015. A magnetic resonance imaging (MRI was performed, that showed evidence of choledocholithiasis, in addition to a possible biliary leakage. The patient was treated with ultrasound-guided drainage and ERCP successfully. Discussion: Spontaneous perforation of the biliary tract is a disease entity in which wall of the extrahepatic or intrahepatic duct is perforated without any traumatic or iatrogenic injury. The clinical presentation varies from nonspecific abdominal pain to biliary peritonitis, in most of the cases forming bilomas. Universal management involves decompression of the biliary tree and repair of the leak site. Conclusion: The spontaneous perforation of the biliary tract is a disease that represents a diagnostic challenge. The treatment in the patients with SPBT is not well established and has to be individualized for each case, depending on the history of the patient, the site of perforation, the time of evolution, the suspicion of infection, and the patient status. Keywords: Acute abdomen, Spontaneous perforation biliary tract, Biloma, Complication choledocholithiasis, Case report

  8. Magnetic Levitation Force Measurement System at Any Low Temperatures From 20 K To 300 K

    Science.gov (United States)

    Celik, Sukru; Guner, S. Baris; Coskun, Elvan

    2015-03-01

    Most of the magnetic levitation force measurements in previous studies were performed at liquid nitrogen temperatures. For the levitation force of MgB2 and iron based superconducting samples, magnetic levitation force measurement system is needed. In this study, magnetic levitation force measurement system was designed. In this system, beside vertical force versus vertical motion, lateral and vertical force versus lateral motion measurements, the vertical force versus temperature at the fixed distance between permanent magnet PM - superconducting sample SS and the vertical force versus time measurements were performed at any temperatures from 20 K to 300 K. Thanks to these measurements, the temperature dependence, time dependence, and the distance (magnetic field) and temperature dependences of SS can be investigated. On the other hand, the magnetic stiffness MS measurements can be performed in this system. Using the measurement of MS at different temperature in the range, MS dependence on temperature can be investigated. These measurements at any temperatures in the range help to the superconductivity properties to be characterized. This work was supported by TUBTAK-the Scientific and technological research council of Turkey under project of MFAG - 110T622. This system was applied to the Turkish patent institute with the Application Number of 2013/13638 on 22/11/2013.

  9. Peritonitis - spontaneous bacterial

    Science.gov (United States)

    Spontaneous bacterial peritonitis (SBP); Ascites - peritonitis; Cirrhosis - peritonitis ... who are on peritoneal dialysis for kidney failure. Peritonitis may have other causes . These include infection from ...

  10. Search for spontaneous fission of 226Ra and systematics of the spontaneous fission, α-decay and cluster decay probabilities

    International Nuclear Information System (INIS)

    Mikheev, V.L.; Tret'yakova, S.P.; Golovchenko, A.N.; Timofeeva, O.V.; Hussonnois, M.; Le Naour, C.

    1998-01-01

    The low limit of the 226 Ra spontaneous fission half-life corresponding to T 1/2 ≥ 4 · 10 18 years is measured. The 226 Ra spontaneous fission probability proved to be about 50 times less than the value expected from the known systematics, connecting the ratios of theα-decay and spontaneous fission probabilities with the fissility parameter Z 2 /A. It is shown that the probabilities of spontaneous fission, α-decay and cluster decay can be systematized in the same way according to the difference between the decay products Coulomb energy near the scission point and decay energy Q

  11. Automated protein identification by the combination of MALDI MS and MS/MS spectra from different instruments.

    Science.gov (United States)

    Levander, Fredrik; James, Peter

    2005-01-01

    The identification of proteins separated on two-dimensional gels is most commonly performed by trypsin digestion and subsequent matrix-assisted laser desorption ionization (MALDI) with time-of-flight (TOF). Recently, atmospheric pressure (AP) MALDI coupled to an ion trap (IT) has emerged as a convenient method to obtain tandem mass spectra (MS/MS) from samples on MALDI target plates. In the present work, we investigated the feasibility of using the two methodologies in line as a standard method for protein identification. In this setup, the high mass accuracy MALDI-TOF spectra are used to calibrate the peptide precursor masses in the lower mass accuracy AP-MALDI-IT MS/MS spectra. Several software tools were developed to automate the analysis process. Two sets of MALDI samples, consisting of 142 and 421 gel spots, respectively, were analyzed in a highly automated manner. In the first set, the protein identification rate increased from 61% for MALDI-TOF only to 85% for MALDI-TOF combined with AP-MALDI-IT. In the second data set the increase in protein identification rate was from 44% to 58%. AP-MALDI-IT MS/MS spectra were in general less effective than the MALDI-TOF spectra for protein identification, but the combination of the two methods clearly enhanced the confidence in protein identification.

  12. Microstructure and soft magnetic properties of Finemet-type ribbons obtained by twin-roller melt-spinning

    International Nuclear Information System (INIS)

    Pozo Lopez, G.; Fabietti, L.M.; Condo, A.M.; Urreta, S.E.

    2010-01-01

    Soft magnetic ribbons of Finemet-type (Fe 73.5 Cu 1 Nb 3 Si 13.5 B 9 ) alloys are synthesized by the twin-roller melt-spinning technique directly from the melt, at tangential wheel speeds of 15, 18, 19 and 20 m/s. The microstructure and the magnetic properties are characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), differential thermal analysis (DTA), thermo-gravimetric analysis (TGA) and hysteresis loops measurements. Samples cooled at 20 m/s are amorphous, while those quenched at lower wheel speeds are partially crystalline. All samples studied present saturation magnetization values (150-160 A m 2 /kg) higher than the commercial Finemet alloys (∼135 A m 2 /kg), obtained by controlled crystallization of amorphous single-roller melt-spun alloys. Optimal soft magnetic properties - σ S =(154±8) A m 2 /kg and H C =(6.9±0.9) A/m - are found in samples quenched at 19 m/s, consisting of size-distributed bcc Fe-Si nanograins (∼18 nm in average) embedded in an amorphous residual matrix. A minority nanocrystalline magnetic phase (≤10 nm) is also detected.

  13. Maternal smoking predicts the risk of spontaneous abortion

    DEFF Research Database (Denmark)

    Nielsen, Ann; Hannibal, Charlotte Gerd; Lindekilde, Bodil Eriksen

    2006-01-01

    BACKGROUND: Few studies have examined smoking prior to pregnancy and the occurrence of spontaneous abortion, as most studies have addressed the risk of spontaneous abortion in relation to smoking during pregnancy. However, results are not entirely consistent. The aim of the present study...... was to assess the risk of spontaneous abortion considering smoking prior to pregnancy. METHODS: We performed a nested case-control study using prospective data from a population-based cohort comprising 11,088 women aged 20-29 years. From this cohort, women who experienced either a spontaneous abortion (n=343......) or who gave birth (n=1,578) during follow-up were selected. Associations between self-reported smoking at enrollment and subsequent spontaneous abortion were analyzed by means of multiple logistic regression. RESULTS: The risk of spontaneous abortion in relation to pre-pregnancy smoking showed a clear...

  14. Thermally activated magnetization reversal in monatomic magnetic chains on surfaces studied by classical atomistic spin-dynamics simulations

    International Nuclear Information System (INIS)

    Bauer, David S G; Mavropoulos, Phivos; Bluegel, Stefan; Lounis, Samir

    2011-01-01

    We analyse the spontaneous magnetization reversal of supported monatomic chains of finite length due to thermal fluctuations via atomistic spin-dynamics simulations. Our approach is based on the integration of the Landau-Lifshitz equation of motion of a classical spin Hamiltonian in the presence of stochastic forces. The associated magnetization lifetime is found to obey an Arrhenius law with an activation barrier equal to the domain wall energy in the chain. For chains longer than one domain wall width, the reversal is initiated by nucleation of a reversed magnetization domain primarily at the chain edge followed by a subsequent propagation of the domain wall to the other edge in a random-walk fashion. This results in a linear dependence of the lifetime on the chain length, if the magnetization correlation length is not exceeded. We studied chains of uniaxial and triaxial anisotropy and found that a triaxial anisotropy leads to a reduction of the magnetization lifetime due to a higher reversal attempt rate, even though the activation barrier is not changed.

  15. Remnant magnetization of Fe8 high-spin molecules: X-ray magnetic circular dichroism at 300 mK

    Science.gov (United States)

    Letard, Isabelle; Sainctavit, Philippe; dit Moulin, Christophe Cartier; Kappler, Jean-Paul; Ghigna, Paolo; Gatteschi, Dante; Doddi, Bruno

    2007-06-01

    Fe8 high-spin molecules exhibit quantum spin tunneling at very low temperatures. Eight Fe3+ ions are sixfold coordinated and magnetically coupled through oxygen bridges. The net magnetization (MS=20 μB per molecule) results from competing antiferromagnetic interactions between the various Fe3+ ions (S =5/2). Because of the structural anisotropy of these molecules, the magnetization curve presents a hysteresis loop with staircases below 2 K. The staircases of the hysteresis loop are due to the quantum spin tunneling, which is temperature dependent for 400 mKmolecule. It has been possible to register an XMCD remnant signal, without magnetic field applied, at the iron L2,3 edges. XMCD coupled with ligand field multiplet calculations has allowed to determine the spin and orbit contributions to the magnetization of the Fe3+ ions.

  16. Molecular analysis of intact preen waxes of Calidris Canutus (Aves: Scolopacidae) by GC/MS and GC/MS/MS

    NARCIS (Netherlands)

    Sinninghe Damsté, J.S.; Dekker, M.H.A.; Piersma, T.

    2000-01-01

    The intact preen wax esters of the red knot Calidris canutus were studied with gas chromatography/mass spectrometry (GC/MS) and GC/MS/MS. In this latter technique, transitions from the molecular ion to fragment ions representing the fatty acid moiety of the wax esters were measured, providing

  17. Situation and person attributions under spontaneous and intentional instructions: an fMRI study

    Science.gov (United States)

    Kestemont, Jenny; Vandekerckhove, Marie; Ma, Ning; Van Hoeck, Nicole

    2013-01-01

    This functional magnetic resonance imaging (fMRI) research explores how observers make causal beliefs about an event in terms of the person or situation. Thirty-four participants read various short descriptions of social events that implied either the person or the situation as the cause. Half of them were explicitly instructed to judge whether the event was caused by something about the person or the situation (intentional inferences), whereas the other half was instructed simply to read the material carefully (spontaneous inferences). The results showed common activation in areas related to mentalizing, across all types of causes or instructions (posterior superior temporal sulcus, temporo-parietal junction, precuneus). However, the medial prefrontal cortex was activated only under spontaneous instructions, but not under intentional instruction. This suggests a bias toward person attributions (e.g. fundamental attribution bias). Complementary to this, intentional situation attributions activated a stronger and more extended network compared to intentional person attributions, suggesting that situation attributions require more controlled, extended and broader processing of the information. PMID:22345370

  18. Osteonecrosis or spontaneous fractures following renal transplantation

    International Nuclear Information System (INIS)

    Andresen, J.; Nielsen, H.E.; Aarhus Univ.

    1981-01-01

    31 renal transplant recipients with posttransplant development of osteonecrosis or spontaneous fractures were evaluated with regard to age, duration of dialysis before transplantation. Determination of metacarpal bone mass at the time of transplantation and registration of bone resorption and soft tissue calcification at the time of transplantation and at the time of onset of osteonecrosis and spontaneous fractures were made. Apart from the increased mean age in patients with spontaneous fractures no difference was seen between the groups. Osteonecrosis and spontaneous fractures occurred in areas of trabecular bone. It seems most likely that after renal transplantation the patients show bone complications of different localization. (orig.) [de

  19. Spontaneous transfer of magnetically stored energy to Kinetic energy by electric double layers

    International Nuclear Information System (INIS)

    Lindberg, L.; Torven, S.

    1983-05-01

    Current disruptions are investigated in a magnetized plasma column with an inductive external electric circuit. It is found that they persist in spite of the fact that each disruption gives rise to a large inductive over-voltage. This drops off at an electric double layer formed in the plasma where most of the magnetic energy, initially stored in the circuit inductance, is released as particle energy. Simultanously as the current disrupts, the potential level at a local potential minimum in the plasma decreases. This is expected to cause the disruption by reflection of electrons. (authors)

  20. Spontaneous Recovery from Unresponsive Wakefulness Syndrome to a Minimally Conscious State: Early Structural Changes Revealed by 7-T Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Xufei Tan

    2018-01-01

    Full Text Available BackgroundDetermining the early changes of brain structure that occur from vegetative state/unresponsive wakefulness syndrome (VS/UWS to a minimally conscious state (MCS is important for developing our understanding of the processes underlying disorders of consciousness (DOC, particularly during spontaneous recovery from severe brain damage.ObjectiveThis study used a multi-modal neuroimaging approach to investigate early structural changes during spontaneous recovery from VS/UWS to MCS.MethodsThe Coma Recovery Scale-Revised (CRS-R score, 24-h electroencephalography (EEG, and ultra-high field 7-T magnetic resonance imaging were used to investigate a male patient with severe brain injury when he was in VS/UWS compared to MCS. Using white matter connectometry analysis, fibers in MCS were compared with the same fibers in VS/UWS. Whole-brain analysis was used to compare all fibers showing a 10% increase in density with each other as a population.ResultsBased on connectometry analysis, the number of fibers with increased density, and the magnitude of increase in MCS compared to VS/UWS, was greatest in the area of the temporoparietal junction (TPJ, and was mostly located in the right hemisphere. These results are in accordance with the active areas observed on 24-h EEG recordings. Moreover, analysis of different fibers across the brain, showing at least a 10% increase in density, revealed that altered white matter connections with higher discriminative weights were located within or across visual-related areas, including the cuneus_R, calcarine_R, occipital_sup_R, and occipital_mid_R. Furthermore, the temporal_mid_R, which is related to the auditory cortex, showed the highest increase in connectivity to other areas. This was consistent with improvements in the visual and auditory components of the CRS-R, which were greater than other improvements.ConclusionThese results provide evidence to support the important roles for the TPJ and the visual and

  1. Localized atrophy of the thalamus and slowed cognitive processing speed in MS patients.

    Science.gov (United States)

    Bergsland, Niels; Zivadinov, Robert; Dwyer, Michael G; Weinstock-Guttman, Bianca; Benedict, Ralph Hb

    2016-09-01

    Deep gray matter (DGM) atrophy is common in multiple sclerosis (MS), but no studies have investigated surface-based structure changes over time with respect to healthy controls (HCs). Moreover, the relationship between cognition and the spatio-temporal evolution of DGM atrophy is poorly understood. To explore DGM structural differences between MS and HCs over time in relation to neuropsychological (NP) outcomes. The participants were 44 relapsing-remitting and 20 secondary progressive MS patients and 22 HCs. All were scanned using 3T magnetic resonance imaging (MRI) at baseline and 3-year follow-up. NP examination emphasized consensus standard tests of processing speed and memory. We performed both volumetric and shape analysis of DGM structures and assessed their relationships with cognition. Compared to HCs, MS patients presented with significantly smaller DGM volumes. For the thalamus and caudate, differences in shape were mostly localized along the lateral ventricles. NP outcomes were related to both volume and shape of the DGM structures. Over 3 years, decreased cognitive processing speed was related to localized atrophy on the anterior and superior surface of the left thalamus. These findings highlight the role of atrophy in the anterior nucleus of the thalamus and its relation to cognitive decline in MS. © The Author(s), 2015.

  2. A Case of Spontaneously Resolved Bilateral Primary Spontaneous Pneumothorax

    Directory of Open Access Journals (Sweden)

    Hasan Kahraman

    2014-03-01

    Full Text Available A condition of intrapleural air-space accumulation in individuals without any history of trauma or lung disease is called as primary spontaneous pneumothorax (PSP. Sixteen-years-old male patient admitted with complains of chest pain and dyspnea beginning 3 day ago. On physical examination, severity of breath sounds decreased on right side. Chest radiograph was taken and right-sided pneumothorax was detected and tube thoracostomy was inserted. Two months ago the patient referred to a doctor with similar complaints and physical examination and chest radiograph were reported as normal. The radiograph was retrospectively examined and bilateral PSP was detected. We presented the case duo to spontaneous recovery of bilateral PSP is seen very rarely and so contributes data to the literature. In patients admitted to the clinic with chest pain and shortness of breath, pneumothorax should be considered at differential diagnosis.

  3. Maternal underweight and the risk of spontaneous abortion

    DEFF Research Database (Denmark)

    Helgstrand, Stine; Andersen, Anne-Marie Nybo

    2005-01-01

    BACKGROUND: To evaluate the risk of spontaneous abortion in relation to maternal pre-pregnant underweight. METHODS: The study was designed as a cohort study within the framework of the Danish National Birth Cohort (DNBC). The participants were a total of 23 821 women recruited consecutively...... spontaneous abortion. Relative risk of spontaneous abortion was calculated as Hazard Ratios using Cox regression with delayed entry. RESULTS: The outcome measure was spontaneous abortion. The hazard ratio for spontaneous abortion in women with a pre-pregnant body mass index (BMI) below 18.5 was 1.24 (95......% confidence limits 0.95-1.63) compared to women with pre-pregnant BMI 18.5-24.9. Women with a BMI of 25 or more had a smaller increase in risk of spontaneous abortion. Adjustment for maternal age, parity, previous miscarriages, and lifestyle factors did not affect the estimates substantially, neither did...

  4. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Definition of MS Myelin Immune-Mediated Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters ... d Research News & Progress Research News MSPARIS2017 Stem Cells in MS Progressive MS Research Clinical Trials in ...

  5. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... MS Relapsing-remitting MS (RRMS) Share this page Facebook Twitter Email Relapsing-remitting MS (RRMS) Relapsing-remitting ... Here Start Here Colophon Stay Informed Join Us Facebook Twitter LinkedIn YouTube Pinterest MS Connection About the ...

  6. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... d Living Well with MS d Diet, Exercise & Healthy Behaviors Diet & Nutrition Exercise Heat & Temperature Sensitivity Sleep Vaccinations Women's Health Unhealthy Habits Managing MS and Another Condition Aging with MS Anesthesia and Surgery Managing Your MS ...

  7. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... to navigation Skip to content Menu Navigation National Multiple Sclerosis Society Sign In In Your Area Donate Donate ... of MS What Causes MS? Who Gets MS? Multiple Sclerosis FAQs Types of MS Related Conditions Symptoms & Diagnosis ...

  8. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Relapsing-remitting MS (RRMS) Share this page Facebook Twitter Email Relapsing-remitting MS (RRMS) Relapsing-remitting MS ( ... Start Here Colophon Stay Informed Join Us Facebook Twitter LinkedIn YouTube Pinterest MS Connection About the Society ...

  9. Spontaneous deregulation

    NARCIS (Netherlands)

    Edelman, Benjamin; Geradin, Damien

    Platform businesses such as Airbnb and Uber have risen to success partly by sidestepping laws and regulations that encumber their traditional competitors. Such rule flouting is what the authors call “spontaneous private deregulation,” and it’s happening in a growing number of industries. The authors

  10. Quasi-Two-Dimensional Magnetism in Co-Based Shandites

    Science.gov (United States)

    Kassem, Mohamed A.; Tabata, Yoshikazu; Waki, Takeshi; Nakamura, Hiroyuki

    2016-06-01

    We report quasi-two-dimensional (Q2D) itinerant electron magnetism in the layered Co-based shandites. Comprehensive magnetization measurements were performed using single crystals of Co3Sn2-xInxS2 (0 ≤ x ≤ 2) and Co3-yFeySn2S2 (0 ≤ y ≤ 0.5). The magnetic parameters of both systems; the Curie temperature TC, effective moment peff and spontaneous moment ps; exhibit almost identical variations against the In- and Fe-concentrations, indicating significance of the electron count on the magnetism in the Co-based shandite. The ferromagnetic-nonmagnetic quantum phase transition is found around xc ˜ 0.8. Analysis based on the extended Q2D spin fluctuation theory clearly reveals the highly Q2D itinerant electron character of the ferromagnetism in the Co-based shandites.

  11. A case of spontaneous ventriculocisternostomy

    International Nuclear Information System (INIS)

    Yamane, Kanji; Yoshimoto, Hisanori; Harada, Kiyoshi; Uozumi, Tohru; Kuwabara, Satoshi.

    1983-01-01

    The authors experienced a case of spontaneous ventriculocisternostomy diagnosed by CT scan with metrizamide and Conray. Patient was 23-year-old male who had been in good health until one month before admission, when he began to have headache and tinnitus. He noticed bilateral visual acuity was decreased about one week before admission and vomiting appeared two days before admission. He was admitted to our hospital because of bilateral papilledema and remarkable hydrocephalus diagnosed by CT scan. On admission, no abnormal neurological signs except for bilateral papilledema were noted. Immediately, right ventricular drainage was performed. Pressure of the ventricle was over 300mmH 2 O and CSF was clear. PVG and PEG disclosed an another cavity behind the third ventricle, which was communicated with the third ventricle, and occlusion of aqueduct of Sylvius. Metrizamide CT scan and Conray CT scan showed a communication between this cavity and quadrigeminal and supracerebellar cisterns. On these neuroradiological findings, the diagnosis of obstructive hydrocephalus due to benign aqueduct stenosis accompanied with spontaneous ventriculocisternostomy was obtained. Spontaneous ventriculocisternostomy was noticed to produce arrest of hydrocephalus, but with our case, spontaneous regression of such symptoms did not appeared. By surgical ventriculocisternostomy (method by Torkildsen, Dandy, or Scarff), arrest of hydrocephalus was seen in about 50 to 70 per cent, which was the same results as those of spontaneous ventriculocisternostomy. It is concluded that VP shunt or VA shunt is thought to be better treatment of obstructive hydrocephalus than the various kinds of surgical ventriculocisternostomy. (J.P.N.)

  12. Magnetic sensor for steady state tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Neyatani, Yuzuru; Mori, Katsuharu; Oguri, Shigeru; Kikuchi, Mitsuru [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1996-06-01

    A new type of magnetic sensor has been developed for the measurement of steady state magnetic fields without DC-drift such as integration circuit. The electromagnetic force induced to the current which leads to the sensor was used for the measurement. For the high frequency component which exceeds higher than the vibration frequency of sensor, pick-up coil was used through the high pass filter. From the results using tokamak discharges, this sensor can measure the magnetic field in the tokamak discharge. During {approx}2 hours measurement, no DC drift was observed. The sensor can respond {approx}10ms of fast change of magnetic field during disruptions. We confirm the extension of measured range to control the current which leads to the sensor. (author).

  13. Physical properties of elongated magnetic particles: magnetization and friction coefficient anisotropies.

    Science.gov (United States)

    Vereda, Fernando; de Vicente, Juan; Hidalgo-Alvarez, Roque

    2009-06-02

    Anisotropy counts: A brief review of the main physical properties of elongated magnetic particles (EMPs) is presented. The most important characteristic of an EMP is the additional contribution of shape anisotropy to the total anisotropy energy of the particle, when compared to spherical magnetic particles. The electron micrograph shows Ni-ferrite microrods fabricated by the authors.We present an overview of the main physical properties of elongated magnetic particles (EMPs), including some of their more relevant properties in suspension. When compared to a spherical magnetic particle, the most important characteristic of an EMP is an additional contribution of shape anisotropy to the total anisotropy energy of the particle. Increasing aspect ratios also lead to an increase in both the critical single-domain size of a magnetic particle and its resistance to thermally activated spontaneous reversal of the magnetization. For single-domain EMPs, magnetization reversal occurs primarily by one of two modes, coherent rotation or curling, the latter being facilitated by larger aspect ratios. When EMPs are used to prepare colloidal suspensions, other physical properties come into play, such as their anisotropic friction coefficient and the consequent enhanced torque they experience in a shear flow, their tendency to align in the direction of an external field, to form less dense sediments and to entangle into more intricate aggregates. From a more practical point of view, EMPs are discussed in connection with two interesting types of magnetic colloids: magnetorheological fluids and suspensions for magnetic hyperthermia. Advances reported in the literature regarding the use of EMPs in these two systems are included. In the final section, we present a summary of the most relevant methods documented in the literature for the fabrication of EMPs, together with a list of the most common ferromagnetic materials that have been synthesized in the form of EMPs.

  14. MAGNETOHYDRODYNAMICS STUDY OF THREE-DIMENSIONAL FAST MAGNETIC RECONNECTION FOR INTERMITTENT SNAKE-LIKE DOWNFLOWS IN SOLAR FLARES

    International Nuclear Information System (INIS)

    Shimizu, T.; Kondo, K.; Ugai, M.; Shibata, K.

    2009-01-01

    Three-dimensional instability of the spontaneous fast magnetic reconnection is studied with magnetohydrodynamics (MHD) simulation, where the two-dimensional model of the spontaneous fast magnetic reconnection is destabilized in three dimensions. In two-dimensional models, every plasma condition is assumed to be uniform in the sheet current direction. In that case, it is well known that the two-dimensional fast magnetic reconnection can be caused by current-driven anomalous resistivity, when an initial resistive disturbance is locally put in a one-dimensional current sheet. In this paper, it is studied whether the two-dimensional fast magnetic reconnection can be destabilized or not when the initial resistive disturbance is three dimensional, i.e., that which has weak fluctuations in the sheet current direction. According to our study, the two-dimensional fast magnetic reconnection is developed to the three-dimensional intermittent fast magnetic reconnection which is strongly localized in the sheet current direction. The resulting fast magnetic reconnection repeats to randomly eject three-dimensional magnetic loops which are very similar to the intermittent downflows observed in solar flares. In fact, in some observations of solar flares, the current sheet seems to be approximately one dimensional, but the fast magnetic reconnection is strongly localized in the sheet current direction, i.e., fully three dimensional. In addition, the observed plasma downflows as snake-like curves. It is shown that those observed features are consistent with our numerical MHD study.

  15. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... the Challenges of MS You CAN! Webcasts DVDs Books For Kids: Keep S'myelin Información en Español Brochures ... Managing MS and Another Condition Aging with MS Anesthesia and Surgery Managing Your MS d Emotional Well- ...

  16. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... the Challenges of MS You CAN! Webcasts DVDs Books For Kids: Keep S'myelin Información en Español Brochures ... MS Managing MS Resources for You and Your Practice Publications for Clinicians Publications for Your Patients MS ...

  17. EPR and EOM studies in well samples from some Venezuelan oil fields: correlation with magnetic authigenesis

    International Nuclear Information System (INIS)

    Diaz, M.; Aldana, M.; Sequera, P.; Costanzo A, V.; Jimenez, S.M.

    2006-01-01

    Electron paramagnetic resonance (EPR), magnetic susceptibility (MS) and extractable organic matter (EOM) measurements were carried out in drilling fines, from near-surface levels, from producer and non-producer wells, with the purpose of examining a possible causal relationship between magnetic contrasts and underlying hydrocarbons. Organic matter free radical concentration (OMFRC) and EOM anomalies were found only at the producer wells, in the same zone where MS anomalies were observed. The EOM anomalies coincide in depth with the MS ones, while the OMFRC anomalies lie close to them. The results could be explained if a net transfer of electrons from reduced organic matter, possible induced by the underlying reservoir, to Fe(lII) (e.g. hematite) occurs. This process alters the original organic matter and produces the formation of EOM and Fe(ll) magnetic minerals (e.g. magnetite), with both anomalies coexisting. (Author)

  18. Evaluation of pulsing magnetic field effects on paresthesia in multiple sclerosis patients, a randomized, double-blind, parallel-group clinical trial.

    Science.gov (United States)

    Afshari, Daryoush; Moradian, Nasrin; Khalili, Majid; Razazian, Nazanin; Bostani, Arash; Hoseini, Jamal; Moradian, Mohamad; Ghiasian, Masoud

    2016-10-01

    Evidence is mounting that magnet therapy could alleviate the symptoms of multiple sclerosis (MS). This study was performed to test the effects of the pulsing magnetic fields on the paresthesia in MS patients. This study has been conducted as a randomized, double-blind, parallel-group clinical trial during the April 2012 to October 2013. The subjects were selected among patients referred to MS clinic of Imam Reza Hospital; affiliated to Kermanshah University of Medical Sciences, Iran. Sixty three patients with MS were included in the study and randomly were divided into two groups, 35 patients were exposed to a magnetic pulsing field of 4mT intensity and 15-Hz frequency sinusoidal wave for 20min per session 2 times per week over a period of 2 months involving 16 sessions and 28 patients was exposed to a magnetically inactive field (placebo) for 20min per session 2 times per week over a period of 2 months involving 16 sessions. The severity of paresthesia was measured by the numerical rating scale (NRS) at 30, 60days. The study primary end point was NRS change between baseline and 60days. The secondary outcome was NRS change between baseline and 30days. Patients exposing to magnetic field showed significant paresthesia improvement compared with the group of patients exposing to placebo. According to our results pulsed magnetic therapy could alleviate paresthesia in MS patients .But trials with more patients and longer duration are mandatory to describe long-term effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. pDeep: Predicting MS/MS Spectra of Peptides with Deep Learning.

    Science.gov (United States)

    Zhou, Xie-Xuan; Zeng, Wen-Feng; Chi, Hao; Luo, Chunjie; Liu, Chao; Zhan, Jianfeng; He, Si-Min; Zhang, Zhifei

    2017-12-05

    In tandem mass spectrometry (MS/MS)-based proteomics, search engines rely on comparison between an experimental MS/MS spectrum and the theoretical spectra of the candidate peptides. Hence, accurate prediction of the theoretical spectra of peptides appears to be particularly important. Here, we present pDeep, a deep neural network-based model for the spectrum prediction of peptides. Using the bidirectional long short-term memory (BiLSTM), pDeep can predict higher-energy collisional dissociation, electron-transfer dissociation, and electron-transfer and higher-energy collision dissociation MS/MS spectra of peptides with >0.9 median Pearson correlation coefficients. Further, we showed that intermediate layer of the neural network could reveal physicochemical properties of amino acids, for example the similarities of fragmentation behaviors between amino acids. We also showed the potential of pDeep to distinguish extremely similar peptides (peptides that contain isobaric amino acids, for example, GG = N, AG = Q, or even I = L), which were very difficult to distinguish using traditional search engines.

  20. Efficacy of tricaine methanesulfonate (MS-222 as an anesthetic agent for blocking sensory-motor responses in Xenopus laevis tadpoles.

    Directory of Open Access Journals (Sweden)

    Carlana Ramlochansingh

    Full Text Available Anesthetics are drugs that reversibly relieve pain, decrease body movements and suppress neuronal activity. Most drugs only cover one of these effects; for instance, analgesics relieve pain but fail to block primary fiber responses to noxious stimuli. Alternately, paralytic drugs block synaptic transmission at neuromuscular junctions, thereby effectively paralyzing skeletal muscles. Thus, both analgesics and paralytics each accomplish one effect, but fail to singularly account for all three. Tricaine methanesulfonate (MS-222 is structurally similar to benzocaine, a typical anesthetic for anamniote vertebrates, but contains a sulfate moiety rendering this drug more hydrophilic. MS-222 is used as anesthetic in poikilothermic animals such as fish and amphibians. However, it is often argued that MS-222 is only a hypnotic drug and its ability to block neural activity has been questioned. This prompted us to evaluate the potency and dynamics of MS-222-induced effects on neuronal firing of sensory and motor nerves alongside a defined motor behavior in semi-intact in vitro preparations of Xenopus laevis tadpoles. Electrophysiological recordings of extraocular motor discharge and both spontaneous and evoked mechanosensory nerve activity were measured before, during and after administration of MS-222, then compared to benzocaine and a known paralytic, pancuronium. Both MS-222 and benzocaine, but not pancuronium caused a dose-dependent, reversible blockade of extraocular motor and sensory nerve activity. These results indicate that MS-222 as benzocaine blocks the activity of both sensory and motor nerves compatible with the mechanistic action of effective anesthetics, indicating that both caine-derivates are effective as single-drug anesthetics for surgical interventions in anamniotes.

  1. Magnetic susceptibility evolution and sedimentary environments on carbonate platform sediments and atolls, comparison of the Frasnian from Belgium and Alberta, Canada

    Science.gov (United States)

    da Silva, Anne-Christine; Potma, Ken; Weissenberger, John A. W.; Whalen, Michael T.; Humblet, Marc; Mabille, Cédric; Boulvain, Frédéric

    2009-02-01

    Magnetic susceptibility (MS) measurements on carbonate rocks are considered as a proxy for impurities delivered to the carbonate environments. In the absence of strong climatic or tectonic variations, bulk MS values have been linked to sea level variations, because sea-level fall increases clastic supply and therefore increases in magnetic mineral deposition. In this paper we explore the relationship between the average magnitude of bulk MS, with shallowing-up sequences and facies evolution in different Devonian carbonate complexes. Similarities and differences between these parameters have been scrutinized in carbonate attached platform and detached platforms (mounds and/or atolls) from Belgium and Canada. In the carbonate attached platforms from Belgium and Canada, the MS patterns are directly related to depositional environment. Mean MS values increase from the most distal towards the most proximal facies and towards the top of the majority of fourth-order shallowing-up sequences. These trends are in agreement with theoretical background (MS increases with regression). In the Belgian detached platform, the average MS pattern generally shows an opposite behaviour to that observed in the attached carbonate platforms. Average MS decreases towards the most proximal facies and towards the top of a majority of the fourth-order shallowing-up sequences. This behaviour can be explained by the influence of sedimentary rate and water agitation during deposition. A high sedimentary rate will dilute the magnetic minerals in the atoll facies and the high water agitation during deposition may be expected to have prevented the deposition of the magnetic grains. So, the combination of these two effects will result in the observed low values in the atoll crown and lagoonal facies. In the Canadian detached platform, MS is mainly negative. This means that the limestones are very pure. The technique does not appear to be appropriate in these rocks. The variations of average MS

  2. Synthesis and spectroscopic characterization of magnetic hydroxyapatite nanocomposite using ultrasonic irradiation

    Science.gov (United States)

    Gopi, D.; Ansari, M. Thameem; Shinyjoy, E.; Kavitha, L.

    2012-02-01

    Nowadays magnetic hydroxyapatite (m-HAP) has potential applications in biomedicine more especially for bone cancer treatment. In this paper the functionalization of the hydroxyapatite (HAP) with magnetite nanoparticle (MNP) through ultrasonic irradiation technique is reported and its spectral investigation has been carried out. The ultrasonic irradiation with two different frequencies of 28 kHz and 35 kHz at the power of 150 and 320 W, respectively, was employed for the synthesis of m-HAP. The ultrasound irradiation of 35 kHz at 320 W shows the efficient diffusion of MNP to the HAP host matrix leads to the formation of m-HAP. The ultrasonic irradiation technique does not require stabilizers as in the case of coprecipitation method hence the final product of pure m-HAP is obtained. The X-ray diffraction pattern shows the formation of magnetite nanoparticles which are functionalized with hydroxyapatite host matrix. The vibrating sample magnetometer curve exhibits the super paramagnetic property of the samples and the saturation magnetization ( Ms) value of the functionalized magnetic hydroxyapatite. The Ms value is found to be much less than that of pure magnetite nanoparticle and this decrement in Ms is due to the hindrance of magnetic domain of the particles with HAP. The portrayed Raman spectra discriminate between the m-HAP and MNP with corresponding vibrational modes of frequencies. The transmission electron micrograph shows excellent morphology of functionalized m-HAP in nanometer range. The atomic force microscopic investigation shows the 3-dimensional view of crust and trench shape of m-HAP. All these results confirm the formation of magnetic hydroxyapatite nanocomposite with typical magnetic property for biological applications.

  3. Brain spontaneous fluctuations in sensorimotor regions were directly related to eyes open and eyes closed: evidences from a machine learning approach

    Directory of Open Access Journals (Sweden)

    Bishan eLiang

    2014-08-01

    Full Text Available Previous studies have demonstrated that the difference between resting-state brain activations depends on whether the subject was eyes open (EO or eyes closed (EC. However, whether the spontaneous fluctuations are directly related to these two different resting states are still largely unclear. In the present study, we acquired resting-state functional magnetic resonance imaging data from 24 healthy subjects (11 males, 20.17 ± 2.74 years under the EO and EC states. The amplitude of the spontaneous brain activity in low-frequency band was subsequently investigated by using the metric of fractional amplitude of low frequency fluctuation (fALFF for each subject under each state. A support vector machine (SVM analysis was then applied to evaluate whether the category of resting states could be determined from the brain spontaneous fluctuations. We demonstrated that these two resting states could be decoded from the identified pattern of brain spontaneous fluctuations, predominantly based on fALFF in the sensorimotor module. Specifically, we observed prominent relationships between increased fALFF for EC and decreased fALFF for EO in sensorimotor regions. Overall, the present results indicate that a SVM performs well in the discrimination between the brain spontaneous fluctuations of distinct resting states and provide new insight into the neural substrate of the resting states during EC and EO.

  4. Encephalic magnetic resonance imaging in spinal clinical forms of multiple sclerosis

    International Nuclear Information System (INIS)

    Lubetzki, C.; Lyon-Caen, O.; Lhermitte, F.; Iba-Zizen, M.T.

    1988-01-01

    The diagnosis of multiple sclerosis (MS) in patients presenting with signs and symptoms of pure spinal cord involvement is always difficult. Previous studies have shown the usefulness of encephalic magnetic resonance imaging (MRI) of the brain in those cases. The aim was to evaluate the diagnosis value of brain MRI in medullar forms of MS. 3 refs

  5. Magnetic materials research with polarized neutrons

    International Nuclear Information System (INIS)

    Hammer, J.; Rauch, H.; Badurek, G.

    1980-01-01

    In order to study the mechanisms of time dependent effects in magnetic materials with superparamagnetic or spinglass behaviour as well as in ferromagnetic materials a 'dynamic neutron depolarization' system has been developed as a beam hole experiment at the TRIGA Mark II Reactor in Vienna. In the course of this experiment an increasing or decreasing polarization can be observed as a consequence of the interaction between spins of the polarized neutron beam and the magnetic structure if the magnetic clusters in the sample are stimulated by a short magnetic pulse, lasting up to a few seconds. In accordance with numerical calculations and theoretical considerations we can draw conclusions from dynamics in the range of 10 ms to 1 h within magnetic materials which give us additional information that cannot be obtained from experiments used so far

  6. Synthesis of magnetic systems producing field with maximal scalar characteristics

    International Nuclear Information System (INIS)

    Klevets, Nickolay I.

    2005-01-01

    A method of synthesis of the magnetic systems (MSs) consisting of uniformly magnetized blocks is proposed. This method allows to synthesize MSs providing maximum value of any magnetic field scalar characteristic. In particular, it is possible to synthesize the MSs providing the maximum of a field projection on a given vector, a gradient of a field modulus and a gradient of a field energy on a given directing vector, a field magnitude, a magnetic flux through a given surface, a scalar product of a field or a force by a directing function given in some area of space, etc. The synthesized MSs provide maximal efficiency of permanent magnets utilization. The usage of the proposed method of MSs synthesis allows to change a procedure of projecting in principal, namely, to execute it according to the following scheme: (a) to choose the sizes, a form and a number of blocks of a system proceeding from technological (economical) reasons; (b) using the proposed synthesis method, to find an orientation of site magnetization providing maximum possible effect of magnet utilization in a system obtained in (a). Such approach considerably reduces a time of MSs projecting and guarantees maximal possible efficiency of magnets utilization. Besides it provides absolute assurance in 'ideality' of a MS design and allows to obtain an exact estimate of the limit parameters of a field in a working area of a projected MS. The method is applicable to a system containing the components from soft magnetic material with linear magnetic properties

  7. MacMS: A Mass Spectrometer Simulator: Abstract of Issue 9906M

    Science.gov (United States)

    Bigger, Stephen W.; Craig, Robert A.

    1999-10-01

    MacMS is a program for Mac-OS compatible computers that simulates a magnetic sector mass spectrometer (1-4) designed to operate in the mass-to-charge (m/z) ratio range of 1-200 amu. MacMS has two operational modules. The first module (see Figure 1) is called the "Path" module and enables the user to quantitatively examine the trajectory of an ion of given m/z ratio in the electric and magnetic fields of the simulated "instrument". By systematically measuring a series of trajectories of different ions under different electric and magnetic field conditions, the user can determine how the resolution of the "instrument" is affected by these experimentally variable parameters. The user can thus choose suitable instrumental conditions for scanning a given m/z ratio range with good separation between the peaks. The second module (see Figure 2) is called as the "Spectrometer" module and enables the user to record, under any chosen instrumental conditions, the mass spectrum of (i) the instrumental background, (ii) neon, (iii) methane, or (iv) the parent ion of carbon tetrachloride. Both voltage scanning and magnetic scanning are possible (5). A hard copy of any mass spectrum that has been recorded can also be obtained. MacMS can read ASCII data files containing mass spectral information of compounds other than those that are "built-in" to the simulator. The appropriate format for creating such data files is described in the program documentation. There are a number of instructional exercises that can be conducted using the mass spectral information contained within the simulator. These are included in the program documentation. For example, the intensities of the 20Ne+, 21Ne+, and 22Ne+ species can be determined from hard copies of mass spectra of neon that are obtained under different instrumental sensitivities. The relative abundances of the three isotopes of neon can thus be calculated and compared with the literature values (6). The simulator also includes adjustable

  8. Study of ion viscosity by spontaneous L-H transitions under marginal hot cathode biasing in the Tohoku University Heliac

    International Nuclear Information System (INIS)

    Kitajima, S.; Takahashi, H.; Tanaka, Y.; Utoh, H.; Takenaga, M.; Yokoyama, M.; Inagaki, S.; Suzuki, Y.; Nishimura, K.; Ogawa, H.; Takayama, M.; Shinde, J.; Ogawa, M.; Aoyama, H.; Iwazaki, K.; Okamoto, A.; Shinto, K.; Sasao, M.

    2008-01-01

    Using the spontaneous transition condition under marginal hot cathode biasing, the ion viscosity at the L-H transition was estimated in various magnetic configurations in the Tohoku University Heliac. The critical viscosity, which is the viscosity at the transition point, was experimentally estimated from the J x B driving force. The critical viscosities in different magnetic configurations were in agreement with the neoclassical predictions within a factor of 2 and were compared with the viscosities obtained in the externally forced biasing experiments. Although the transition points were spread over a wide range, poloidal Mach numbers at the transition point were concentrated near the viscosity maxima predicted by the theory

  9. Ferro-based derivatizing agents for LC/MS an LC/EC/MS

    NARCIS (Netherlands)

    Seiwert, Bettina

    2007-01-01

    Within this thesis, the development and application of ferrocene-based derivatizing agents for LC/MS and LC/EC/MS is presented. The advantages of derivatization by ferrocenes are the similtaneous introduction of a mass tag and an electroactive group, which make them ideally suited for LC/MS and

  10. Quantifying emissions from spontaneous combustion

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-09-01

    Spontaneous combustion can be a significant problem in the coal industry, not only due to the obvious safety hazard and the potential loss of valuable assets, but also with respect to the release of gaseous pollutants, especially CO2, from uncontrolled coal fires. This report reviews methodologies for measuring emissions from spontaneous combustion and discusses methods for quantifying, estimating and accounting for the purpose of preparing emission inventories.

  11. Application of CE-ICP-MS and CE-ESI-MS/MS for identification of Zn-binding ligands in Goji berries extracts.

    Science.gov (United States)

    Ruzik, Lena; Kwiatkowski, Piotr

    2018-06-01

    The identification of groups of ligands binding metals is a crucial issue for the better understanding of their bioaccessibility. In the current study, we have intended an approach for identification of Zn-binding ligands based on using capillary electrophoresis combined with inductively coupled plasma mass spectrometry (CE-ICP-MS) and tandem electrospray ionization mass spectrometry (CE-ESI-MS/MS). The approach, which featured the use of the coupling of capillary electrophoresis with inductively coupled plasma mass spectrometry allows to separate and observe zinc ions present in complexes with respect to their size and charge and to identify nine compounds with zinc isotopic profile. CE-ICP-MS provides us with information about presence of zinc species and elemental information about zinc distribution. CE-ESI-MS/MS provide us with information about the most favorable Zn binding ligands: amino acids, flavonols, stilbenoids, fenolic acids and carotenoids. The presented work is the continuation of previous studies based on using LC-ESI-MS/MS, though, now we presented a new solutions with the possibility of changing detectors without changing the separation techniques, what is important without re-optimizing the method. The new presented method allows to identify the zinc-binding ligands in shorter time. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Magnetic force microscopy and simulation studies on Co50Fe50 ...

    Indian Academy of Sciences (India)

    2Department of Electronics and Communication Engineering, Keshav Memorial ... along the major axis and the pictures were recorded in zero ... The material parameters used in the simulations are saturation magnetization MS = 1.9 × 106 A m. −1. , exchange .... magnets of thickness 10 and 60 nm were carried out system-.

  13. Analysis of pesticide residues in strawberries and soils by GC-MS/MS, LC-MS/MS and two-dimensional GC-time-of-flight MS comparing organic and integrated pest management farming.

    Science.gov (United States)

    Fernandes, Virgínia C; Lehotay, Steven J; Geis-Asteggiante, Lucía; Kwon, Hyeyoung; Mol, Hans G J; van der Kamp, Henk; Mateus, Nuno; Domingues, Valentina F; Delerue-Matos, Cristina

    2014-01-01

    This study analysed 22 strawberry and soil samples after their collection over the course of 2 years to compare the residue profiles from organic farming with integrated pest management practices in Portugal. For sample preparation, we used the citrate-buffered version of the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method. We applied three different methods for analysis: (1) 27 pesticides were targeted using LC-MS/MS; (2) 143 were targeted using low pressure GC-tandem mass spectrometry (LP-GC-MS/MS); and (3) more than 600 pesticides were screened in a targeted and untargeted approach using comprehensive, two-dimensional gas chromatography time-of-flight mass spectrometry (GC × GC-TOF-MS). Comparison was made of the analyses using the different methods for the shared samples. The results were similar, thereby providing satisfactory confirmation of both similarly positive and negative findings. No pesticides were found in the organic-farmed samples. In samples from integrated pest management practices, nine pesticides were determined and confirmed to be present, ranging from 2 µg kg(-1) for fluazifop-p-butyl to 50 µg kg(-1) for fenpropathrin. Concentrations of residues in strawberries were less than European maximum residue limits.

  14. Research on spontaneous activity in adult anisometropic amblyopia with regional homogeneity

    Science.gov (United States)

    Huang, Yufeng; Zhou, Yifeng

    2017-06-01

    Amblyopia usually occurs in early childhood and results in monocular visual impairment. The functional magnetic resonance imaging (fMRI) studies have reflected functional anomaly in amblyopia. In resting-state fMRI study, spontaneous activity changes abnormally in anisometropic amblyopia could be revealed by the regional homogeneity (ReHo). Twenty two adult anisometropic amblyopes and Twenty one normal controls participated in this fMRI study. Two sample T test was carried out to analysis ReHo within the whole brain for the inter groups. Compare with normal group, our study found that the amblyopia’s ReHo mainly increased in the left frontal lobe, while decreased in the left cerebellum, the temporal lobe (left and right), and the left parietal lobe. And the ReHo values in middle and inferior temporal lobe, the prefrontal lobe, frontal lobe (positive) and parietal lobe and medial frontal gyrus (negative) could be correlated with the acuity deficit of amblyopia. The results increased in ReHo may indicate compensatory plasticity in higher vision information process, while the decreased in ReHo may reflect decreased ability in eye movement, spatial sense and visuo-motor coordination. The correlation revealed that the vision deficit may correspond to the spontaneous in certain brain area.

  15. Quantitative Determination of Perfluorochemicals and Fluorotelomer Alcohols in Plants from Biosolid-Amended Fields using LC/MS/MS and GC/MS

    Science.gov (United States)

    Analytical methods for determining perfluorochemicals (PFCs) and fluorotelomer alcohols (FTOHs) in plants using liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) were developed, and applied to quantify a suite of analytes i...

  16. In Vivo Metabolism Study of Xiamenmycin A in Mouse Plasma by UPLC-QTOF-MS and LC-MS/MS

    Directory of Open Access Journals (Sweden)

    Feng Lei

    2015-01-01

    Full Text Available Xiamenmycin A is an antifibrotic leading compound with a benzopyran skeleton that is isolated from mangrove-derived Streptomyces xiamenensis. As a promising small molecule for fibrotic diseases, less information is known about its metabolic characteristics in vivo. In this study, the time-course of xiamenmycin A in mouse plasma was investigated by relative quantification. After two types of administration of xiamenmycin A at a single dose of 10 mg/kg, the plasma concentrations were measured quantitatively by LC-MS/MS. The dynamic changes in the xiamenmycin A concentration showed rapid absorption and quick elimination in plasma post-administration. Four metabolites (M1–M4 were identified in blood by UPLC-QTOF-MS, and xiamenmycin B (M3 is the principal metabolite in vivo, as verified by comparison of the authentic standard sample. The structures of other metabolites were identified based on the characteristics of their MS and MS/MS data. The newly identified metabolites are useful for understanding the metabolism of xiamenmycin A in vivo, aiming at the development of an anti-fibrotic drug candidate for the therapeutic treatment of excessive fibrotic diseases.

  17. Continuous development of current sheets near and away from magnetic nulls

    International Nuclear Information System (INIS)

    Kumar, Sanjay; Bhattacharyya, R.

    2016-01-01

    The presented computations compare the strength of current sheets which develop near and away from the magnetic nulls. To ensure the spontaneous generation of current sheets, the computations are performed congruently with Parker's magnetostatic theorem. The simulations evince current sheets near two dimensional and three dimensional magnetic nulls as well as away from them. An important finding of this work is in the demonstration of comparative scaling of peak current density with numerical resolution, for these different types of current sheets. The results document current sheets near two dimensional magnetic nulls to have larger strength while exhibiting a stronger scaling than the current sheets close to three dimensional magnetic nulls or away from any magnetic null. The comparative scaling points to a scenario where the magnetic topology near a developing current sheet is important for energetics of the subsequent reconnection.

  18. Magnetic memory signals variation induced by applied magnetic field and static tensile stress in ferromagnetic steel

    International Nuclear Information System (INIS)

    Huang, Haihong; Yang, Cheng; Qian, Zhengchun; Han, Gang; Liu, Zhifeng

    2016-01-01

    Stress can induce a spontaneous magnetic field in ferromagnetic steel under the excitation of geomagnetic field. In order to investigate the impact of applied magnetic field and tensile stress on variation of the residual magnetic signals on the surface of ferromagnetic materials, static tensile tests of Q235 structural steel were carried out, with the normal component of the residual magnetic signals, H p (y), induced by applied magnetic fields with different intensities measured through the tensile tests. The H p (y), its slope coefficient K S and maximum gradient K max changing with the applied magnetic field H and tensile stress were observed. Results show that the magnitude of H p (y) and its slope coefficient K S increase linearly with the increase of stress in the elastic deformation stage. Under yield stress, H p (y) and K S reach its maximum, and then decrease slightly with further increase of stress. Applied magnetic field affects the magnitude of H p (y) instead of changing the signal curve′s profile; and the magnitude of H p (y), K S , K max and the change rate of K S increase with the increase of applied magnetic field. The phenomenon is also discussed from the viewpoint of magnetic charge in ferromagnetic materials. - Highlights: • We investigated how applied magnetic field and tensile stress impact H p (y) signals. • Magnitude of H p (y), K S and K max increase with the increase of applied magnetic field. • Both applied magnetic field and tensile stress impact material magnetic permeability. • Applied magnetic field can help to evaluate the stress distribution of components.

  19. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Become an MS Activist Take Action Current Advocacy Issues Advocacy Results Advocacy News d Raise Awareness d ... MS are more likely to experience gradually worsening problems with walking and mobility, along with whatever other symptoms they may have. Diagnosing relapsing-remitting MS (RRMS) Learn More Learn More ... Room MS Prevalence ...

  20. Spontaneous Activity Associated with Delusions of Schizophrenia in the Left Medial Superior Frontal Gyrus: A Resting-State fMRI Study.

    Directory of Open Access Journals (Sweden)

    Bin Gao

    Full Text Available Delusions of schizophrenia have been found to be associated with alterations of some brain regions in structure and task-induced activation. However, the relationship between spontaneously occurring symptoms and spontaneous brain activity remains unclear. In the current study, 14 schizophrenic patients with delusions and 14 healthy controls underwent a resting-state functional magnetic resonance imaging (RS-fMRI scan. Patients with delusions of schizophrenia patients were rated with Positive and Negative Syndrome Scale (PANSS and Characteristics of Delusional Rating Scale (CDRS. Regional homogeneity (ReHo was calculated to measure the local synchronization of the spontaneous activity in a voxel-wise way. A two-sample t-test showed that ReHo of the right anterior cingulate gyrus and left medial superior frontal gyrus were higher in patients, and ReHo of the left superior occipital gyrus was lower, compared to healthy controls. Further, among patients, correlation analysis showed a significant difference between delusion scores of CRDS and ReHo of brain regions. ReHo of the left medial superior frontal gyrus was negatively correlated with patients' CDRS scores but not with delusional PANSS scores. These results suggested that altered local synchronization of spontaneous brain activity may be related to the pathophysiology of delusion in schizophrenia.

  1. Spontaneous Activity Associated with Delusions of Schizophrenia in the Left Medial Superior Frontal Gyrus: A Resting-State fMRI Study.

    Science.gov (United States)

    Gao, Bin; Wang, Yiquan; Liu, Weibo; Chen, Zhiyu; Zhou, Heshan; Yang, Jinyu; Cohen, Zachary; Zhu, Yihong; Zang, Yufeng

    2015-01-01

    Delusions of schizophrenia have been found to be associated with alterations of some brain regions in structure and task-induced activation. However, the relationship between spontaneously occurring symptoms and spontaneous brain activity remains unclear. In the current study, 14 schizophrenic patients with delusions and 14 healthy controls underwent a resting-state functional magnetic resonance imaging (RS-fMRI) scan. Patients with delusions of schizophrenia patients were rated with Positive and Negative Syndrome Scale (PANSS) and Characteristics of Delusional Rating Scale (CDRS). Regional homogeneity (ReHo) was calculated to measure the local synchronization of the spontaneous activity in a voxel-wise way. A two-sample t-test showed that ReHo of the right anterior cingulate gyrus and left medial superior frontal gyrus were higher in patients, and ReHo of the left superior occipital gyrus was lower, compared to healthy controls. Further, among patients, correlation analysis showed a significant difference between delusion scores of CRDS and ReHo of brain regions. ReHo of the left medial superior frontal gyrus was negatively correlated with patients' CDRS scores but not with delusional PANSS scores. These results suggested that altered local synchronization of spontaneous brain activity may be related to the pathophysiology of delusion in schizophrenia.

  2. Removal of malathion from aqueous solution using De-Acidite FF-IP resin and determination by UPLC-MS/MS: equilibrium, kinetics and thermodynamics studies.

    Science.gov (United States)

    Naushad, Mu; Alothman, Z A; Khan, M R

    2013-10-15

    In the present study, De-Acidite FF-IP resin was used to remove a highly toxic and persistent organophosphorus pesticide (malathion) from the aqueous solution. Batch experiments were performed as a function of various experimental parameters such as effect of pH (2-10), contact time (10-120 min), resin dose (0.05-0.5 g), initial malathion concentration (0.5-2.5 µg mL(-1)) and temperature (25-65°C). The concentration of malathion was determined using a sensitive, selective and rapid ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. The uptake rate of malathion on De-Acidite FF-IP resin was rapid and equilibrium established within 40 min. Kinetics studies showed better applicability for pseudo-second-order model. The equilibrium data was fitted to Langmuir and Freundlich isotherm models and the isotherm constants were calculated for malathion. The values of thermodynamic parameters (ΔG(0), ΔH(0) and ΔS(0)) were computed from the Van't Hoff plot of lnKC vs. 1/T which showed that the adsorption of malathion was feasible, endothermic and spontaneous. The regeneration studies were carried out which demonstrated a decrease in the recovery of malathion from 95% to 68% after five consecutive cycles. Breakthrough and exhaustive capacities of malathion were found to be 1.25 mg g(-1) and 3.5 mg g(-1), respectively. © 2013 Elsevier B.V. All rights reserved.

  3. High Ms Fe16N2 thin film with Ag under layer on GaAs substrate

    Energy Technology Data Exchange (ETDEWEB)

    Allard Jr, Lawrence Frederick [ORNL

    2016-01-01

    (001) textured Fe16N2 thin film with Ag under layer is successfully grown on GaAs substrate using a facing target sputtering (FTS) system. After post annealing, chemically ordered Fe16N2 phase is formed and detected by X-ray diffraction (XRD). High saturation magnetization (Ms) is measured by a vibrating sample magnetometer (VSM). In comparison with Fe16N2 with Ag under layer on MgO substrate and Fe16N2 with Fe under layer on GaAs substrate, the current layer structure shows a higher Ms value, with a magnetically softer feature in contrast to the above cases. In addition, X-ray photoelectron spectroscopy (XPS) is performed to characterize the binding energy of N atoms. To verify the role of strain that the FeN layer experiences in the above three structures, Grazing Incidence X-ray Diffraction (GIXRD) is conducted to reveal a large in-plane lattice constant due to the in-plane biaxial tensile strain. INTRODUCTION

  4. Survey of diagnostic and treatment practices for multiple sclerosis (MS) in Europe. Part 2: Progressive MS, paediatric MS, pregnancy and general management.

    Science.gov (United States)

    Fernández, O; Delvecchio, M; Edan, G; Fredrikson, S; Giovannoni, G; Hartung, H-P; Havrdova, E; Kappos, L; Pozzilli, C; Soerensen, P S; Tackenberg, B; Vermersch, P; Comi, G

    2018-05-01

    The European Charcot Foundation supported the development of a set of surveys to understand current practice patterns for the diagnosis and management of multiple sclerosis (MS) in Europe. Part 2 of the report summarizes survey results related to secondary progressive MS (SPMS), primary progressive MS (PPMS), pregnancy, paediatric MS and overall patient management. A steering committee of MS neurologists developed case- and practice-based questions for two sequential surveys distributed to MS neurologists throughout Europe. Respondents generally favoured changing rather than stopping disease-modifying treatment (DMT) in patients transitioning from relapsing-remitting MS to SPMS, particularly with active disease. Respondents would not initiate DMT in patients with typical PPMS symptoms, although the presence of ≥1 spinal cord or brain gadolinium-enhancing lesion might affect that decision. For patients considering pregnancy, respondents were equally divided on whether to stop treatment before or after conception. Respondents strongly favoured starting DMT in paediatric MS with active disease; recommended treatments included interferon, glatiramer acetate and, in John Cunningham virus negative patients, natalizumab. Additional results regarding practice-based questions and management are summarized. Results of part 2 of the survey of diagnostic and treatment practices for MS in Europe largely mirror results for part 1, with neurologists in general agreement about the treatment and management of SPMS, PPMS, pregnancy and paediatric MS as well as the general management of MS. However, there are also many areas of disagreement, indicating the need for evidence-based recommendations and/or guidelines. © 2018 EAN.

  5. Sulphur fertilization influences the sulphur species composition in Allium sativum: sulphomics using HPLC-ICPMS/MS-ESI-MS/MS.

    Science.gov (United States)

    Raab, Andrea; Ronzan, Marilena; Feldmann, Joerg

    2017-10-18

    Garlic (A. sativum) contains a large number of small sulphur (S)-containing metabolites, which are important for its taste and smell and vary with A. sativum variety and growth conditions. This study was designed to investigate the influence of different sulphur-fertilization regimes on low molecular weight S-species by attempting the first sulphur mass balance in A. sativum roots and bulbs using HPLC-ICPMS/MS-ESI-MS/MS. Species unspecific quantification of acid soluble S-containing metabolites was achieved using HPLC-ICP-MS/MS. For identification of the compounds, high resolution ESI-MS (Orbitrap LTQ and q-TOF) was used. The plants contained up to 54 separated sulphur-containing compounds, which constitute about 80% of the total sulphur present in A. sativum. The roots and bulbs of A. sativum contained the same compounds, but not necessarily the same amounts and proportions. The S-containing metabolites in the roots reacted more sensitively to manipulations of sulphur fertilization than those compounds in the bulbs. In addition to known compounds (e.g. γ-glutamyl-S-1-propenylcysteine) we were able to identify and partially quantify 31 compounds. Three as yet undescribed S-containing compounds were also identified and quantified for the first time. Putative structures were assigned to the oxidised forms of S-1-propenylmercaptoglutathione, S-2-propenylmercaptoglutathione, S-allyl/propenyl-containing PC-2 and 2-amino-3-[(2-carboxypropyl)sulfanyl]propanoic acid. The parallel use of ICP-MS/MS as a sulphur-specific detector and ESI-MS as a molecular detector simplifies the identification and quantification of sulphur containing metabolites without species specific standards. This non-target analysis approach enables a mass balance approach and identifies the occurrence of the so far unidentified organosulphur compounds. The experiments showed that the sulphur-fertilization regime does not influence sulphur-speciation, but the concentration of some S

  6. Neural Substrates of Spontaneous Narrative Production in Focal Neurodegenerative Disease

    Science.gov (United States)

    Gola, Kelly A.; Thorne, Avril; Veldhuisen, Lisa D.; Felix, Cordula M.; Hankinson, Sarah; Pham, Julie; Shany-Ur, Tal; Schauer, Guido P.; Stanley, Christine M.; Glenn, Shenly; Miller, Bruce L.; Rankin, Katherine P.

    2016-01-01

    Conversational storytelling integrates diverse cognitive and socio-emotional abilities that critically differ across neurodegenerative disease groups and may have diagnostic relevance and predict anatomic changes. The present study employed mixed methods discourse and quantitative analyses to delineate patterns of storytelling across focal neurodegenerative disease groups, and to clarify the neuroanatomical contributions to common storytelling characteristics in these patients. Transcripts of spontaneous social interactions of 46 participants (15 behavioral variant frontotemporal dementia (bvFTD), 7 semantic variant primary progressive aphasia (svPPA), 12 Alzheimer's disease (AD), and 12 healthy older normal controls) were analysed for storytelling characteristics and frequency, and videos of the interactions were rated for patients' social attentiveness. Compared to controls, svPPAs also told more stories and autobiographical stories, and perseverated on aspects of self during storytelling. ADs told fewer autobiographical stories than NCs, and svPPAs and bvFTDs failed to attend to social cues. Storytelling characteristics were associated with a processing speed and mental flexibility, and voxel-based anatomic analysis of structural magnetic resonance imaging revealed that temporal organization, evaluations, and social attention correlated with atrophy corresponding to known intrinsic connectivity networks, including the default mode, limbic, salience, and stable task control networks. Differences in spontaneous storytelling among neurodegenerative groups elucidated diverse cognitive, socio-emotional, and neural contributions to narrative production, with implications for diagnostic screening and therapeutic intervention. PMID:26485159

  7. Magnetic nanowires (Fe, Fe-Co, Fe-Ni – magnetic moment reorientation in respect of wires composition

    Directory of Open Access Journals (Sweden)

    Kalska-Szostko Beata

    2015-03-01

    Full Text Available Magnetic nanowires of Fe, Fe-Co, and Fe-Ni alloy and layered structure were prepared by electrochemical alternating current (AC deposition method. The morphology of the nanowires in and without the matrix was studied by energy dispersive X-ray spectroscopy (EDX, scanning electron microscopy (SEM, and X-ray diffraction (XRD, respectively. The wires either show strong dependence on the combination of elements deposition (alloy or layered or chemical composition (Co or Ni. The magnetic properties of the nanostructures were determined on the basis of Mössbauer spectroscopy (MS.

  8. Plasma membrane isolation using immobilized concanavalin A magnetic beads.

    Science.gov (United States)

    Lee, Yu-Chen; Srajer Gajdosik, Martina; Josic, Djuro; Lin, Sue-Hwa

    2012-01-01

    Isolation of highly purified plasma membranes is the key step in constructing the plasma membrane proteome. Traditional plasma membrane isolation method takes advantage of the differential density of organelles. While differential centrifugation methods are sufficient to enrich for plasma membranes, the procedure is lengthy and results in low recovery of the membrane fraction. Importantly, there is significant contamination of the plasma membranes with other organelles. The traditional agarose affinity matrix is suitable for isolating proteins but has limitation in separating organelles due to the density of agarose. Immobilization of affinity ligands to magnetic beads allows separation of affinity matrix from organelles through magnets and could be developed for the isolation of organelles. We have developed a simple method for isolating plasma membranes using lectin concanavalin A (ConA) magnetic beads. ConA is immobilized onto magnetic beads by binding biotinylated ConA to streptavidin magnetic beads. The ConA magnetic beads are used to bind glycosylated proteins present in the membranes. The bound membranes are solubilized from the magnetic beads with a detergent containing the competing sugar alpha methyl mannoside. In this study, we describe the procedure of isolating rat liver plasma membranes using sucrose density gradient centrifugation as described by Neville. We then further purify the membrane fraction by using ConA magnetic beads. After this purification step, main liver plasma membrane proteins, especially the highly glycosylated ones and proteins containing transmembrane domains could be identified by LC-ESI-MS/MS. While not described here, the magnetic bead method can also be used to isolate plasma membranes from cell lysates. This membrane purification method should expedite the cataloging of plasma membrane proteome.

  9. Evaluation of the antihypertensive properties of yellow passion fruit pulp (Passiflora edulis Sims f. flavicarpa Deg.) in spontaneously hypertensive rats.

    Science.gov (United States)

    Konta, Eliziane Mieko; Almeida, Mara Ribeiro; do Amaral, Cátia Lira; Darin, Joana Darc Castania; de Rosso, Veridiana V; Mercadante, Adriana Zerlotti; Antunes, Lusânia Maria Greggi; Bianchi, Maria Lourdes Pires

    2014-01-01

    Various species of the genus Passiflora have been extensively used in traditional medicine as sedatives, anxiolytics, diuretics and analgesics. In the present study, after the identification and quantification of phytochemical compounds from yellow passion fruit pulp by liquid chromatography-photodiode array-mass spectrometry (HPLC-PDA-MS/MS), its antihypertensive effect was investigated on spontaneously hypertensive rats. Additionally, the renal function, evaluated by kidney/body weight, serum creatinine, proteinuria, urinary flow, reduced glutathione (GSH) levels and thiobarbituric acid-reactive substances (TBARS) and mutagenicity in bone marrow cells were assessed to evaluate the safety of passion fruit consumption. Yellow passion fruit pulp (5, 6 or 8 g/kg b.w.) was administered by gavage once a day for 5 consecutive days. HLPC-PDA-MS/MS analysis revealed that yellow passion fruit pulp contains phenolic compounds, ascorbic acid, carotenoids and flavonoids. The highest dose of passion fruit pulp significantly reduced the systolic blood pressure, increased the GSH levels and decreased TBARS. There were no changes in renal function parameters or the frequency of micronuclei in bone marrow cells. In conclusion, the antihypertensive effect of yellow passion fruit pulp, at least in part, might be due to the enhancement of the antioxidant status. The exact mechanisms responsible by this effect need further investigation. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Magnetic field induced random pulse trains of magnetic and acoustic noises in martensitic single-crystal Ni2MnGa

    Science.gov (United States)

    Daróczi, Lajos; Piros, Eszter; Tóth, László Z.; Beke, Dezső L.

    2017-07-01

    Jerky magnetic and acoustic noises were evoked in a single variant martensitic Ni2MnGa single crystal (produced by uniaxial compression) by application of an external magnetic field along the hard magnetization direction. It is shown that after reaching the detwinning threshold, spontaneous reorientation of martensite variants (twins) leads not only to acoustic emission but magnetic two-directional noises as well. At small magnetic fields, below the above threshold, unidirectional magnetic emission is also observed and attributed to a Barkhausen-type noise due to magnetic domain wall motions during magnetization along the hard direction. After the above first run, in cycles of decreasing and increasing magnetic field, at low-field values, weak, unidirectional Barkhausen noise is detected and attributed to the discontinuous motion of domain walls during magnetization along the easy magnetization direction. The magnetic noise is also measured by constraining the sample in the same initial variant state along the hard direction and, after the unidirectional noise (as obtained also in the first run), a two-directional noise package is developed and it is attributed to domain rotations. From the statistical analysis of the above noises, the critical exponents, characterizing the power-law behavior, are calculated and compared with each other and with the literature data. Time correlations within the magnetic as well as acoustic signals lead to a common scaled power function (with β =-1.25 exponent) for both types of signals.

  11. F. VON HAYEK’S THEORY OF SPONTANEOUS ORDER

    Directory of Open Access Journals (Sweden)

    О. Nesterenko

    2013-04-01

    Full Text Available The essence and the genesis of spontaneous order are disclosed in the context of critical analysis of constructivism. The author’s approach to the definition of the characteristic features of the spontaneous order is proposed. The dichotomy of the order is revealed towards the economic sphere in form of spontaneous order and organization.

  12. Spontaneous pneumomediastinum after bench press training.

    Science.gov (United States)

    Nishino, Tomoya

    2017-04-01

    Spontaneous pneumomediastinum is often associated with asthma and mainly affects adolescent males with a tall, thin body habitus. A 17-year-old man complained of chest and pharyngeal pain after bench press training and spontaneous pneumomediastinum was diagnosed. It should be considered in the differential diagnosis of chest pain of uncertain cause.

  13. Spontaneous cooperation for prosocials, but not for proselfs: Social value orientation moderates spontaneous cooperation behavior

    Science.gov (United States)

    Mischkowski, Dorothee; Glöckner, Andreas

    2016-01-01

    Cooperation is essential for the success of societies and there is an ongoing debate whether individuals have therefore developed a general spontaneous tendency to cooperate or not. Findings that cooperative behavior is related to shorter decision times provide support for the spontaneous cooperation effect, although contrary results have also been reported. We show that cooperative behavior is better described as person × situation interaction, in that there is a spontaneous cooperation effect for prosocial but not for proself persons. In three studies, one involving population representative samples from the US and Germany, we found that cooperation in a public good game is dependent on an interaction between individuals’ social value orientation and decision time. Increasing deliberation about the dilemma situation does not affect persons that are selfish to begin with, but it is related to decreasing cooperation for prosocial persons that gain positive utility from outcomes of others and score high on the related general personality trait honesty/humility. Our results demonstrate that the spontaneous cooperation hypothesis has to be qualified in that it is limited to persons with a specific personality and social values. Furthermore, they allow reconciling conflicting previous findings by identifying an important moderator for the effect. PMID:26876773

  14. Characterization, stoichiometry, and stability of salivary protein-tannin complexes by ESI-MS and ESI-MS/MS.

    Science.gov (United States)

    Canon, Francis; Paté, Franck; Meudec, Emmanuelle; Marlin, Thérèse; Cheynier, Véronique; Giuliani, Alexandre; Sarni-Manchado, Pascale

    2009-12-01

    Numerous protein-polyphenol interactions occur in biological and food domains particularly involving proline-rich proteins, which are representative of the intrinsically unstructured protein group (IUP). Noncovalent protein-ligand complexes are readily detected by electrospray ionization mass spectrometry (ESI-MS), which also gives access to ligand binding stoichiometry. Surprisingly, the study of interactions between polyphenolic molecules and proteins is still an area where ESI-MS has poorly benefited, whereas it has been extensively applied to the detection of noncovalent complexes. Electrospray ionization mass spectrometry has been applied to the detection and the characterization of the complexes formed between tannins and a human salivary proline-rich protein (PRP), namely IB5. The study of the complex stability was achieved by low-energy collision-induced dissociation (CID) measurements, which are commonly implemented using triple quadrupole, hybrid quadrupole time-of-flight, or ion trap instruments. Complexes composed of IB5 bound to a model polyphenol EgCG have been detected by ESI-MS and further analyzed by MS/MS. Mild ESI interface conditions allowed us to observe intact noncovalent PRP-tannin complexes with stoichiometries ranging from 1:1 to 1:5. Thus, ESI-MS shows its efficiency for (1) the study of PRP-tannin interactions, (2) the determination of stoichiometry, and (3) the study of complex stability. We were able to establish unambiguously both their stoichiometries and their overall subunit architecture via tandem mass spectrometry and solution disruption experiments. Our results prove that IB5.EgCG complexes are maintained intact in the gas phase.

  15. TEST RESULTS FOR LHC INSERTION REGION DEPOLE MAGNETS

    International Nuclear Information System (INIS)

    MURATORE, J.; JAIN, A.; ANERELLA, M.; COSSOLINO, J.

    2005-01-01

    The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They are required to produce fields up to 4.14 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, whose construction was very different from the RHIC dipoles, except for the coil design. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality

  16. Magnetic ordering in arrays of one-dimensional nanoparticle chains

    International Nuclear Information System (INIS)

    Serantes, D; Baldomir, D; Pereiro, M; Hernando, B; Prida, V M; Sanchez Llamazares, J L; Zhukov, A; Ilyn, M; Gonzalez, J

    2009-01-01

    The magnetic order in parallel-aligned one-dimensional (1D) chains of magnetic nanoparticles is studied using a Monte Carlo technique. If the easy anisotropy axes are collinear along the chains a macroscopic mean-field approach indicates antiferromagnetic (AFM) order even when no interparticle interactions are taken into account, which evidences that a mean-field treatment is inadequate for the study of the magnetic order in these highly anisotropic systems. From the direct microscopic analysis of the evolution of the magnetic moments, we observe spontaneous intra-chain ferromagnetic (FM)-type and inter-chain AFM-type ordering at low temperatures (although not completely regular) for the easy-axes collinear case, whereas a random distribution of the anisotropy axes leads to a sort of intra-chain AFM arrangement with no inter-chain regular order. When the magnetic anisotropy is neglected a perfectly regular intra-chain FM-like order is attained. Therefore it is shown that the magnetic anisotropy, and particularly the spatial distribution of the easy axes, is a key parameter governing the magnetic ordering type of 1D-nanoparticle chains.

  17. An improved method of sample preparation on AnchorChip targets for MALDI-MS and MS/MS and its application in the liver proteome project

    DEFF Research Database (Denmark)

    Zhang, Xumin; Shi, Liang; Shu, Shaokung

    2007-01-01

    An improved method for sample preparation for MALDI-MS and MS/MS using AnchorChip targets is presented. The method, termed the SMW method (sample, matrix wash), results in better sensitivity for peptide mass fingerprinting as well as for sequencing by MS/MS than previously published methods. The ...

  18. Magnetic anomalies in Fe-doped NiO nanoparticle

    Science.gov (United States)

    Pradeep, R.; Gandhi, A. C.; Tejabhiram, Y.; Mathar Sahib, I. K. Md; Shimura, Y.; Karmakar, L.; Das, D.; Wu, Sheng Yun; Hayakawa, Y.

    2017-09-01

    Undoped and iron-doped NiO nanoparticle were synthesized by standard hydrothermal method. A detailed study is carried out on the effect of dopant concentration on morphology, structural, resonance and magnetic properties of NiO nanoparticle by varying the Fe concentration from 0.01 to 0.10 M. The synchrotron-x-ray diffraction confirmed that no secondary phase was observed other than NiO. The x-ray photoelectron spectroscopy studies revealed that, Fe was primarily in the trivalent state, replacing the Ni2+ ion inside the octahedral crystal site of NiO. The Electron paramagnetic studies revealed the ferromagnetic cluster formation at high doping concentration (5 and 10%). The ZFC-FC curves displayed an average blocking temperature around 180 K due to particle size distribution. The anomalous behaviour of spontaneous exchange bias (H SEB) and magnetic remanence (M r) for all Fe-doped samples observed at 5 K showed an increase (0.1316-0.1384 emu g-1) in the moment of frozen spin (M p) as the dopant concentration increased. The role of frozen spin moment in spontaneous exchange bias behaviour was discussed.

  19. Reconstruction of human brain spontaneous activity based on frequency-pattern analysis of magnetoencephalography data

    Directory of Open Access Journals (Sweden)

    Rodolfo R Llinas

    2015-10-01

    Full Text Available A new method for the analysis and localization of brain activity has been developed, based on multichannel magnetic field recordings, over minutes, superimposed on the MRI of the individual. Here, a high resolution Fourier Transform is obtained over the entire recording period, leading to a detailed multi-frequency spectrum. Further analysis implements a total decomposition of the frequency components into functionally invariant entities, each having an invariant field pattern localizable in recording space. The method, addressed as functional tomography, makes it possible to find the distribution of magnetic field sources in space. Here, the method is applied to the analysis of simulated data, to oscillating signals activating a physical current dipoles phantom, and to recordings of spontaneous brain activity in ten healthy adults. In the analysis of simulated data, 61 dipoles are localized with 0.7 mm precision. Concerning the physical phantom the method is able to localize three simultaneously activated current dipoles with 1 mm precision. Spatial resolution 3 mm was attained when localizing spontaneous alpha rhythm activity in ten healthy adults, where the alpha peak was specified for each subject individually. Co-registration of the functional tomograms with each subject’s head MRI localized alpha range activity to the occipital and/or posterior parietal brain region. This is the first application of this new functional tomography to human brain activity. The method successfully provides an overall view of brain electrical activity, a detailed spectral description and, combined with MRI, the localization of sources in anatomical brain space.

  20. Reconstruction of human brain spontaneous activity based on frequency-pattern analysis of magnetoencephalography data

    Science.gov (United States)

    Llinás, Rodolfo R.; Ustinin, Mikhail N.; Rykunov, Stanislav D.; Boyko, Anna I.; Sychev, Vyacheslav V.; Walton, Kerry D.; Rabello, Guilherme M.; Garcia, John

    2015-01-01

    A new method for the analysis and localization of brain activity has been developed, based on multichannel magnetic field recordings, over minutes, superimposed on the MRI of the individual. Here, a high resolution Fourier Transform is obtained over the entire recording period, leading to a detailed multi-frequency spectrum. Further analysis implements a total decomposition of the frequency components into functionally invariant entities, each having an invariant field pattern localizable in recording space. The method, addressed as functional tomography, makes it possible to find the distribution of magnetic field sources in space. Here, the method is applied to the analysis of simulated data, to oscillating signals activating a physical current dipoles phantom, and to recordings of spontaneous brain activity in 10 healthy adults. In the analysis of simulated data, 61 dipoles are localized with 0.7 mm precision. Concerning the physical phantom the method is able to localize three simultaneously activated current dipoles with 1 mm precision. Spatial resolution 3 mm was attained when localizing spontaneous alpha rhythm activity in 10 healthy adults, where the alpha peak was specified for each subject individually. Co-registration of the functional tomograms with each subject's head MRI localized alpha range activity to the occipital and/or posterior parietal brain region. This is the first application of this new functional tomography to human brain activity. The method successfully provides an overall view of brain electrical activity, a detailed spectral description and, combined with MRI, the localization of sources in anatomical brain space. PMID:26528119

  1. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... for You and Your Practice Publications for Clinicians Publications for Your Patients MS Navigator Program Programs and Services for Your Patients ... Relapsing-remitting MS (RRMS) Relapsing-remitting MS ( ...

  2. An in silico MS/MS library for automatic annotation of novel FAHFA lipids.

    Science.gov (United States)

    Ma, Yan; Kind, Tobias; Vaniya, Arpana; Gennity, Ingrid; Fahrmann, Johannes F; Fiehn, Oliver

    2015-01-01

    A new lipid class named 'fatty acid esters of hydroxyl fatty acids' (FAHFA) was recently discovered in mammalian adipose tissue and in blood plasma and some FAHFAs were found to be associated with type 2 diabetes. To facilitate the automatic annotation of FAHFAs in biological specimens, a tandem mass spectra (MS/MS) library is needed. Due to the limitation of the commercial available standard compounds, we proposed building an in silico MS/MS library to extend the coverage of molecules. We developed a computer-generated library with 3267 tandem mass spectra (MS/MS) for 1089 FAHFA species. FAHFA spectra were generated based on authentic standards with negative mode electrospray ionization and 10, 20, and 40 V collision induced dissociation at 4 spectra/s as used in in ultra-high performance liquid chromatography-QTOF mass spectrometry studies. However, positional information of the hydroxyl group is only obtained either at lower QTOF spectra acquisition rates of 1 spectrum/s or at the MS(3) level in ion trap instruments. Therefore, an additional set of 4290 fragment-rich MS/MS spectra was created to enable distinguishing positional FAHFA isomers. The library was generated based on ion fragmentations and ion intensities of FAHFA external reference standards, developing a heuristic model for fragmentation rules and extending these rules to large swaths of computer-generated structures of FAHFAs with varying chain lengths, degrees of unsaturation and hydroxyl group positions. Subsequently, we validated the new in silico library by discovering several new FAHFA species in egg yolk, showing that this library enables high-throughput screening of FAHFA lipids in various biological matrices. The developed library and templates are freely available for commercial or noncommercial use at http://fiehnlab.ucdavis.edu/staff/yanma/fahfa-lipid-library. This in silico MS/MS library allows users to annotate FAHFAs from accurate mass tandem mass spectra in an easy and fast manner

  3. Synthesis and magnetic hyperthermia studies on high susceptible Fe1-xMgxFe2O4 superparamagnetic nanospheres

    Science.gov (United States)

    Manohar, A.; Krishnamoorthi, C.

    2017-12-01

    Majority studies on magnetic hyperthermia properties were carried out by modifying the saturation mass magnetization (Ms) of the samples. Here efforts were made to enhance the specific heat generation rate (SHGR) of single domain superparamagnetic (SP) material by modifying its magnetic susceptibility. Well crystallined, inverse spinel structured and close to monosize Fe1-xMgxFe2O4 (x = 0, 0.1, 0.2, 0.3, 0.4, & 0.5) compounds with nanosphere geometry (diameter 10 nm) were synthesized by solvothermal reflux method at ≈ 300 °C . In the literature it is reported that magnesium ferrites synthesized at high temperatures yield mixed (normal & inverse) spinel structures. The inverse spinel structure was confirmed by X-ray powder diffraction (XRPD), lattice vibrations and magnetic characteristics of the compounds. The Ms of the compounds decrease with increase of substituent Mg2+ concentration. Under high excitation energy the inter-valance charge transfer whereas under low excitation energy the intra-valance charge transfer process were predominant. The as-synthesized nanospheres were encapsulated by hydrophobic oleic acid and were exchanged by hydrophilic poly(acrylic acid) by chemical exchange process. Estimated magnetic hyperthermia power or SHGR of the x = 0, 0.3 & 0.5 were 11, 11.4 & 22.4 W per gram of respective compounds, respectively, under 63.4 kA m-1 field amplitude and 126 kHz frequency. The SHGR enhances with Mg2+ concentration though its Ms reduces and is attributed to reduced spin-orbital coupling in the compounds with enhanced Mg2+ concentration. This may pave a new way to develop magnetic hyperthermia material by modifying magnetic susceptibility of the compounds against to the reported Ms modification approach. The obtained high SHGR of the biocompatible compounds could be used in magnetic hyperthermia applications in biomedical field.

  4. Spontaneous ischaemic stroke in dogs

    DEFF Research Database (Denmark)

    Gredal, Hanne Birgit; Skerritt, G. C.; Gideon, P.

    2013-01-01

    Translation of experimental stroke research into the clinical setting is often unsuccessful. Novel approaches are therefore desirable. As humans, pet dogs suffer from spontaneous ischaemic stroke and may hence offer new ways of studying genuine stroke injury mechanisms.......Translation of experimental stroke research into the clinical setting is often unsuccessful. Novel approaches are therefore desirable. As humans, pet dogs suffer from spontaneous ischaemic stroke and may hence offer new ways of studying genuine stroke injury mechanisms....

  5. Spontaneity and international marketing performance

    OpenAIRE

    Souchon, Anne L.; Hughes, Paul; Farrell, Andrew M.; Nemkova, Ekaterina; Oliveira, Joao S.

    2016-01-01

    The file attached to this record is the author's final peer reviewed version. The Publisher's final version can be found by following the DOI link. Purpose – The purpose of this paper is to ascertain how today’s international marketers can perform better on the global scene by harnessing spontaneity. Design/methodology/approach – The authors draw on contingency theory to develop a model of the spontaneity – international marketing performance relationship, and identify three potential m...

  6. LHC magnet quench protection system

    Science.gov (United States)

    Coull, L.; Hagedorn, D.; Remondino, V.; Rodriguez-Mateos, F.

    1994-07-01

    The quench protection system for the superconducting magnets of the CERN Large Hadron Collider (LHC) is described. The system is based on the so called 'cold diode' concept. In a group of series connected magnets if one magnet quenches then the magnetic energy of all the magnets will be dissipated in the quenched magnet so destroying it. This is avoided by by-passing the quenched magnet and then rapidly de-exciting the unquenched magnets. For the LHC machine it is foreseen to use silicon diodes situated inside the cryostat as by-pass elements - so called 'cold diodes'. The diodes are exposed to some 50 kGray of radiation during a 10 year operation life-time. The high energy density of the LHC magnets (500 kJ/m) coupled with the relatively slow propagation speed of a 'natural' quench (10 to 20 m/s) can lead to excessive heating of the zone where the quench started and to high internal voltages. It is therefore necessary to detect quickly the incipient quench and fire strip heaters which spread the quench out more quickly over a large volume of the magnet. After a quench the magnet chain must be de-excited rapidly to avoid spreading the quench to other magnets and over-heating the by-pass diode. This is done by switching high-power energy-dump resistors in series with the magnets. The LHC main ring magnet will be divided into 16 electrically separated units which has important advantages.

  7. LHC magnet quench protection system

    International Nuclear Information System (INIS)

    Coull, L.; Hagedorn, D.; Remondino, V.; Rodriguez-Mateos, F.

    1994-01-01

    The quench protection system for the superconducting magnets of the CERN Large Hadron Collider (LHC) is described. The system is based on the so called ''cold diode'' concept. In a group of series connected magnets if one magnet quenches then the magnetic energy of all the magnets will be dissipated in the quenched magnet so destroying it. This is avoided by by-passing the quenched magnet and then rapidly de-exciting the unquenched magnets. For the LHC machine it is foreseen to use silicon diodes situated inside the cryostat as by-pass elements--so called ''cold diodes''. The diodes are exposed to some 50 kGray of radiation during a 10 year operation life-time. The high energy density of the LHC magnets (500 kJ/m) coupled with the relatively slow propagation speed of a ''natural'' quench (10 to 20 m/s) can lead to excessive heating of the zone where the quench started and to high internal voltages. It is therefore necessary to detect quickly the incipient quench and fire strip heaters which spread the quench out more quickly over a large volume of the magnet. After a quench the magnet chain must be de-excited rapidly to avoid spreading the quench to other magnets and over-heating the by-pass diode. This is done by switching high-power energy-dump resistors in series with the magnets. The LHC main ring magnet will be divided into 16 electrically separated units which has important advantages

  8. Modification of electric and magnetic dipole emission in anisotropic plasmonic systems.

    Science.gov (United States)

    Noginova, N; Hussain, R; Noginov, M A; Vella, J; Urbas, A

    2013-10-07

    In order to investigate the effects of plasmonic environments on spontaneous emission of magnetic and electric dipoles, we have studied luminescence of Eu³⁺ ions in close vicinity to gold nanostrip arrays. Significant changes in the emission kinetics, emission polarization, and radiation patterns have been observed in the wavelength range corresponding to the plasmonic resonance. The effect of the plasmonic resonance on the magnetic dipole transition ⁵D₀-->⁷F₁ is found to be very different from its effect on the electric dipole transitions. This makes Eu³⁺₋ containing complexes promising for mapping local distributions of magnetic and electric fields in metamaterials and plasmonic systems.

  9. Analysis of the Spontaneous Abortion in Chinese Married Women

    Institute of Scientific and Technical Information of China (English)

    高尔生; 邓新清; 何更生; 方可娟; 唐威; 楼超华

    1994-01-01

    The spontaneous abortion is a common type of pregnant outcomes. The spontaneous abortion rate can be used to indicate the women's fecundity and the level of the reproductive health. It is also a sensitive indicator for determing the social, economic, and health status and prenatal care. To explore the preventive method for spontaneous abortion and improve women's health level, it is important to evaluate the status of spontaneous abortion and to determine the factors affecting

  10. Structure Elucidation of Unknown Metabolites in Metabolomics by Combined NMR and MS/MS Prediction.

    Science.gov (United States)

    Boiteau, Rene M; Hoyt, David W; Nicora, Carrie D; Kinmonth-Schultz, Hannah A; Ward, Joy K; Bingol, Kerem

    2018-01-17

    We introduce a cheminformatics approach that combines highly selective and orthogonal structure elucidation parameters; accurate mass, MS/MS (MS²), and NMR into a single analysis platform to accurately identify unknown metabolites in untargeted studies. The approach starts with an unknown LC-MS feature, and then combines the experimental MS/MS and NMR information of the unknown to effectively filter out the false positive candidate structures based on their predicted MS/MS and NMR spectra. We demonstrate the approach on a model mixture, and then we identify an uncatalogued secondary metabolite in Arabidopsis thaliana . The NMR/MS² approach is well suited to the discovery of new metabolites in plant extracts, microbes, soils, dissolved organic matter, food extracts, biofuels, and biomedical samples, facilitating the identification of metabolites that are not present in experimental NMR and MS metabolomics databases.

  11. Analytical Method Details (MS): SE53_MS03 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available SE53_MS03 CE-TOF/MS Agilent CE capillary electrophoresis system,Agilent G3250AA LC/...s were performed using an Agilent CE capillary electrophoresis system (Agilent Technologies, Waldbronn, Germ

  12. Disease protection and interleukin-10 induction by endogenous interferon-β in multiple sclerosis?

    DEFF Research Database (Denmark)

    Hesse, D.; Krakauer, M.; Lund, H

    2011-01-01

    with increased spontaneous MX1 expression also had increased expression of other genes induced by regular IFN-ß treatment of MS. MX1 expression correlated with FOXP3 and IL10 expression, and IL10 expression correlated negatively with disease activity on magnetic resonance imaging. Further, in vivo IL10...... expression was lower in NAb-positive patients than in untreated patients with MS and healthy controls. Finally, ex vivo treatment of mononuclear blood cells with IFN-ß induced the expression of IL10, and this was blocked by the addition of serum from NAb-positive patients with MS. CONCLUSION: Our findings...... suggest that endogenous IFN-ß may induce the expression of immunoregulatory IL10 in MS and that this might be associated with dampening of inflammatory disease activity....

  13. Effects of hydrogenation on magnetism of UNiGe

    Energy Technology Data Exchange (ETDEWEB)

    Adamska, A.M., E-mail: anna@mag.mff.cuni.cz [Department of Condensed Matter Physics, Charles University, Ke Karlovu 5, 12116 Prague 2 (Czech Republic); Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, al. Mickiewicza 30, 30 059 Cracow (Poland); Havela, L. [Department of Condensed Matter Physics, Charles University, Ke Karlovu 5, 12116 Prague 2 (Czech Republic); Prochazka, J. [Faculty of Sports and Physical Education, Charles University, Jose Martiho 31, 16252, Prague 6 (Czech Republic); Andreev, A.V. [Institute of Physics, Academy of Sciences, Na Slovance 2, 18221 Prague (Czech Republic); Skourski, Y. [Dresden High Magnetic Field Laboratory, Helmholtz-Zentrum Dresden-Rossendorf, 01314 Dresden (Germany)

    2011-12-15

    U-based intermetallic compound UNiGe absorbs hydrogen up to the stoichiometry UNiGeH{sub 1.2}. In analogy to other compounds with the TiNiSi-type of structure, the structure is modified into hexagonal. The zig-zag U-chains are stretched, the U-U spacing is largely enhanced and the ordering temperature increases up to 100 K. The ordered state has a spontaneous moment, but it is unlikely to be a simple ferromagnet. - Highlights: > UNiGe exhibits a variety of magnetic properties. > Hydrogenation modifies the crystal, electronic structure, and the magnetic properties. > Upon hydrogenation, the crystal symmetry of UNiGe increases from orthorhombic to hexagonal. > Magnetic ordering temperature of UNiGe (T{sub N}=44 K) is double in the hydride, possible second phase transition.

  14. Potentially stress-induced acute splanchnic segmental arterial mediolysis with a favorable spontaneous outcome

    Directory of Open Access Journals (Sweden)

    Aude Belbezier, MD

    2017-03-01

    Full Text Available A 62-year-old woman presented with hemithoracic anesthesia and acute abdominal pain following a violent psychological stress. Magnetic resonance imaging showed a thoracic hematoma with arachnoiditis of the spinal cord. Tomography revealed a typical aspect of segmental arterial mediolysis with multiple aneurysms and stenoses of the splanchnic arteries, confirmed by abdominal arteriography. There was no argument for hereditary, traumatic, atherosclerotic, infectious, or inflammatory arterial disease. Segmental arterial mediolysis was diagnosed on the basis of the radiologic data and probably involved both medullary and splanchnic arteries. The patient spontaneously recovered and was in good health 18 months later.

  15. Potentially stress-induced acute splanchnic segmental arterial mediolysis with a favorable spontaneous outcome.

    Science.gov (United States)

    Belbezier, Aude; Sarrot-Reynauld, Françoise; Thony, Frédéric; Tahon, Florence; Heck, Olivier; Bouillet, Laurence

    2017-03-01

    A 62-year-old woman presented with hemithoracic anesthesia and acute abdominal pain following a violent psychological stress. Magnetic resonance imaging showed a thoracic hematoma with arachnoiditis of the spinal cord. Tomography revealed a typical aspect of segmental arterial mediolysis with multiple aneurysms and stenoses of the splanchnic arteries, confirmed by abdominal arteriography. There was no argument for hereditary, traumatic, atherosclerotic, infectious, or inflammatory arterial disease. Segmental arterial mediolysis was diagnosed on the basis of the radiologic data and probably involved both medullary and splanchnic arteries. The patient spontaneously recovered and was in good health 18 months later.

  16. Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup.

    Science.gov (United States)

    Cheng, Keding; Sloan, Angela; McCorrister, Stuart; Peterson, Lorea; Chui, Huixia; Drebot, Mike; Nadon, Celine; Knox, J David; Wang, Gehua

    2014-12-01

    The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. Label-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. With LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Magnetic studies of spin wave excitations in Ni/Au multilayers

    International Nuclear Information System (INIS)

    Salhi, H.; Chafai, K.; Benkirane, K.; Lassri, H.; Abid, M.; Hlil, E.K.

    2010-01-01

    Ni/Au multilayers were prepared by the electron beam evaporation method under ultra high vacuum conditions. The multilayer films have a coherent structure with (1 1 1) texture. The magnetic properties of Ni/Au multilayers are examined as a function of Ni layer thickness t Ni . The temperature dependence of the spontaneous magnetization M(T) is well described by a T 3/2 law in all multilayers. A spin wave theory has been used to explain the magnetization versus temperature. Based on this theory, the approximate values for the bulk exchange interaction J b , surface exchange interaction J S and the interlayer coupling strength J I have been obtained for various Ni layer thicknesses.

  18. Multi-Segment Direct Inject nano-ESI-LTQ-FT-ICR-MS/MS For Protein Identification

    Directory of Open Access Journals (Sweden)

    Neal Rachel E

    2011-07-01

    Full Text Available Abstract Reversed phase high performance liquid chromatography (HPLC interfaced to electrospray tandem mass spectrometry (MS/MS is commonly used for the identification of peptides from proteolytically cleaved proteins embedded in a polyacrylamide gel matrix as well as for metabolomics screening. HPLC separations are time consuming (30-60 min average, costly (columns and mobile phase reagents, and carry the risk of column carry over between samples. The use of a chip-based nano-ESI platform (Advion NanoMate based on replaceable nano-tips for sample introduction eliminates sample cross-contamination, provides unchanging sample matrix, and enhances spray stability with attendant increases in reproducibility. Recent papers have established direct infusion nano-ESI-MS/MS utilizing the NanoMate for protein identification of gel spots based on full range MS scans with data dependent MS/MS. In a full range scan, discontinuous ion suppression due to sample matrix can impair identification of putative mass features of interest in both the proteomic and metabolomic workflows. In the current study, an extension of an established direct inject nano-ESI-MS/MS method is described that utilizes the mass filtering capability of an ion-trap for ion packet separation into four narrow mass ranges (50 amu overlap with segment specific dynamic data dependent peak inclusion for MS/MS fragmentation (total acquisition time of 3 minutes. Comparison of this method with a more traditional nanoLC-MS/MS based protocol utilizing solvent/sample stream splitting to achieve nanoflow demonstrated comparable results for protein identification from polyacrylamide gel matrices. The advantages of this method include full automation, lack of cross-contamination, low cost, and high throughput.

  19. Helical undulator based on partial redistribution of uniform magnetic field

    Science.gov (United States)

    Balal, N.; Bandurkin, I. V.; Bratman, V. L.; Fedotov, A. E.

    2017-12-01

    A new type of helical undulator based on redistribution of magnetic field of a solenoid by ferromagnetic helix has been proposed and studied both in theory and experiment. Such undulators are very simple and efficient for promising sources of coherent spontaneous THz undulator radiation from dense electron bunches formed in laser-driven photo-injectors.

  20. Spontaneous Vesicle Recycling in the Synaptic Bouton

    Directory of Open Access Journals (Sweden)

    Sven eTruckenbrodt

    2014-12-01

    Full Text Available The trigger for synaptic vesicle exocytosis is Ca2+, which enters the synaptic bouton following action potential stimulation. However, spontaneous release of neurotransmitter also occurs in the absence of stimulation in virtually all synaptic boutons. It has long been thought that this represents exocytosis driven by fluctuations in local Ca2+ levels. The vesicles responding to these fluctuations are thought to be the same ones that release upon stimulation, albeit potentially triggered by different Ca2+ sensors. This view has been challenged by several recent works, which have suggested that spontaneous release is driven by a separate pool of synaptic vesicles. Numerous articles appeared during the last few years in support of each of these hypotheses, and it has been challenging to bring them into accord. We speculate here on the origins of this controversy, and propose a solution that is related to developmental effects. Constitutive membrane traffic, needed for the biogenesis of vesicles and synapses, is responsible for high levels of spontaneous membrane fusion in young neurons, probably independent of Ca2+. The vesicles releasing spontaneously in such neurons are not related to other synaptic vesicle pools and may represent constitutively releasing vesicles (CRVs rather than bona fide synaptic vesicles. In mature neurons, constitutive traffic is much dampened, and the few remaining spontaneous release events probably represent bona fide spontaneously releasing synaptic vesicles (SRSVs responding to Ca2+ fluctuations, along with a handful of CRVs that participate in synaptic vesicle turnover.

  1. Spontaneous Atraumatic Mediastinal Hemorrhage

    Directory of Open Access Journals (Sweden)

    Morkos Iskander BSc, BMBS, MRCS, PGCertMedEd

    2013-04-01

    Full Text Available Spontaneous atraumatic mediastinal hematomas are rare. We present a case of a previously fit and well middle-aged lady who presented with acute breathlessness and an increasing neck swelling and spontaneous neck bruising. On plain chest radiograph, widening of the mediastinum was noted. The bruising was later confirmed to be secondary to mediastinal hematoma. This life-threatening diagnostic conundrum was managed conservatively with a multidisciplinary team approach involving upper gastrointestinal and thoracic surgeons, gastroenterologists, radiologists, intensivists, and hematologists along with a variety of diagnostic modalities. A review of literature is also presented to help surgeons manage such challenging and complicated cases.

  2. Spontaneous Retropharyngeal Emphysema: A Case Report | Chi ...

    African Journals Online (AJOL)

    ... is a rare clinical condition in pediatric otolaryngology. The predominant symptoms are sore throat, odynophagia, dysphagia, and neck pain. Here, we report a case of spontaneous retropharyngeal emphysema. Keywords: Iatrogenic injury, retropharyngeal emphysema, spontaneous retropharyngeal emphysem, trauma ...

  3. A rare life-threatening disease: unilateral kidney compressed by huge chronic spontaneous retroperitoneal hemorrhage

    Directory of Open Access Journals (Sweden)

    Lu HY

    2018-03-01

    Full Text Available Hao-Yuan Lu,1,* Wei Wei,2,* Qi-Wei Chen,1,* Qing-Gui Meng,1 Gao-Hua Hu,1 Xian-Lin Yi,1,3 Xian-Zhong Bai1 1Department of Urology, Tumor Hospital of Guangxi Medical University and Guangxi Cancer Research Institute, Nanning 530021, China; 2Department of Radiology, Tumor Hospital of Guangxi Medical University and Guangxi Cancer Research Institute, Nanning 530021,China; 3Hubei Engineering Laboratory for Synthetic Microbiology, Wuhan Institute of Biotechnology, Wuhan 430075, China *These authors contributed equally to this work Objectives: To study an uncommon life-threatening disease, spontaneous retroperitoneal and perirenal hemorrhage. Case descriptions: A 69-year-old male presented with pain in the left waist and back of 1 month duration. The renal abscess was suspected by magnetic resonance imaging before operation. The perirenal hematoma was cleaned by operation. In another case, the patient had a functional solitary left kidney compressed by a huge retroperitoneal mass and uropenia appeared. Results: The first patient died of adult respiratory distress syndrome after surgery. The second patient died of cardiac insufficiency and pulmonary embolism on the second day after evacuation of retroperitoneal hematoma. Conclusion: Conservative surgery, such as selective arterial embolization, is a reasonable approach in patients with chronic spontaneous retroperitoneal and perirenal space hemorrhage and with poor general condition. We strongly recommend drainage or interventional therapy, but not a major surgery, in patients with poor condition. Keywords: kidney, spontaneous, retroperitoneal, hemorrhage, surgery

  4. Spontaneous regression of pulmonary bullae

    International Nuclear Information System (INIS)

    Satoh, H.; Ishikawa, H.; Ohtsuka, M.; Sekizawa, K.

    2002-01-01

    The natural history of pulmonary bullae is often characterized by gradual, progressive enlargement. Spontaneous regression of bullae is, however, very rare. We report a case in which complete resolution of pulmonary bullae in the left upper lung occurred spontaneously. The management of pulmonary bullae is occasionally made difficult because of gradual progressive enlargement associated with abnormal pulmonary function. Some patients have multiple bulla in both lungs and/or have a history of pulmonary emphysema. Others have a giant bulla without emphysematous change in the lungs. Our present case had treated lung cancer with no evidence of local recurrence. He had no emphysematous change in lung function test and had no complaints, although the high resolution CT scan shows evidence of underlying minimal changes of emphysema. Ortin and Gurney presented three cases of spontaneous reduction in size of bulla. Interestingly, one of them had a marked decrease in the size of a bulla in association with thickening of the wall of the bulla, which was observed in our patient. This case we describe is of interest, not only because of the rarity with which regression of pulmonary bulla has been reported in the literature, but also because of the spontaneous improvements in the radiological picture in the absence of overt infection or tumor. Copyright (2002) Blackwell Science Pty Ltd

  5. Search for spontaneous conversion of muonium to antimuonium

    International Nuclear Information System (INIS)

    Hughes, V.W.; Ni, B.; Arnold, K.P.

    1987-01-01

    We have searched for spontaneous conversion of muonium (M) to antimuonium M bar by a method involving detection of high-Z muonic X rays. A beam of M atoms with keV energies, produced by electron pickup by μ + from a foil, travels in vacuum and in a magnetic field-free environment to a high-Z target. The event signatures used were a double coincidence of two muonic X rays of the target material and a triple coincidence that also required detection of secondary electrons ejected when M strikes the target. Partial analysis of our 8 x 10 6 triggers indicates upper limits on the effective M →M bar four-dermion coupling constant of G/sub MM bar/ ≤ 30 G/sub F/ (90% C.L.) and G/sub MM bar/ ≤ 8 G/sub F/ (90% C.L.), respectively, from the two signatures. This begins to probe predictions of the left-right symmetric theory with a doubly-charged Higgs triplet

  6. Magnetic fields driven by tidal mixing in radiative stars

    Science.gov (United States)

    Vidal, Jérémie; Cébron, David; Schaeffer, Nathanaël; Hollerbach, Rainer

    2018-04-01

    Stellar magnetism plays an important role in stellar evolution theory. Approximatively 10 per cent of observed main sequence (MS) and pre-main-sequence (PMS) radiative stars exhibit surface magnetic fields above the detection limit, raising the question of their origin. These stars host outer radiative envelopes, which are stably stratified. Therefore, they are assumed to be motionless in standard models of stellar structure and evolution. We focus on rapidly rotating, radiative stars which may be prone to the tidal instability, due to an orbital companion. Using direct numerical simulations in a sphere, we study the interplay between a stable stratification and the tidal instability, and assess its dynamo capability. We show that the tidal instability is triggered regardless of the strength of the stratification (Brunt-Väisälä frequency). Furthermore, the tidal instability can lead to both mixing and self-induced magnetic fields in stably stratified layers (provided that the Brunt-Väisälä frequency does not exceed the stellar spin rate in the simulations too much). The application to stars suggests that the resulting magnetic fields could be observable at the stellar surfaces. Indeed, we expect magnetic field strengths up to several Gauss. Consequently, tidally driven dynamos should be considered as a (complementary) dynamo mechanism, possibly operating in radiative MS and PMS stars hosting orbital companions. In particular, tidally driven dynamos may explain the observed magnetism of tidally deformed and rapidly rotating Vega-like stars.

  7. Metal-doped inorganic nanoparticles for multiplex detection of biomarkers by a sandwich-type ICP-MS immunoassay.

    Science.gov (United States)

    Ko, Jung Aa; Lim, H B

    2016-09-28

    Metal-doped inorganic nanoparticles were synthesized for the multiplex detection of biomarkers by a sandwich-type inductively coupled plasma mass spectrometry (ICP-MS) immunoassay. The synthesized Cs-doped multicore magnetic nanoparticles (MMNPs) were used not only for magnetic extraction of targets but also for ratiometric measurement in ICP-MS. In addition, three different metal/dye-doped silica nanoparticles (SNPs) were synthesized as probes for multiplex detection: Y/RhBITC (rhodamine B isothiocyanate)-doped SNPs for CRP (cardiovascular disease), Cd/RhBITC-doped SNPs for AFP (tumor), and Au/5(6)-XRITC (X-rhodamine-5-(and-6)-isothiocyanate)-doped SNPs for NSE (heart disease). For quantification, the doped metals of SNPs were measured by ICP-MS and then the signal ratio to Cs of MMNPs was plotted with respect to the concentration of targets by a ratiometry. Limits of detection (LOD) of 0.35 ng/mL to 77 ng mL(-1) and recoveries of 83%-125% were obtained for serum samples spiked with the biomarkers. Since no sample treatment was necessary prior to the extraction, the proposed method provided short analysis time and convenience for the multiplex determination of biomarkers, which will be valuable for clinical application. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Video-assisted thoracoscopy treatment of spontaneous pneumothorax

    International Nuclear Information System (INIS)

    Chen Haitao; Ren Jian; Che Jiaming; Hang Junbiao; Qiu Weicheng; Chen Zhongyuan

    2002-01-01

    Objective: To propose a treatment protocol by video thoracoscopy in spontaneous pneumothorax. Methods: One hundred and three patients underwent Video-assisted thoracoscopy (VATS) treatment of spontaneous pneumothorax and hemothorax. Indications included recurrent pneumothorax, persistent air leakage following conservative therapy, complicated hemothorax and CT scan identified bullae formation. Results: No operative deaths occurred, conversion rate was 2.91%, recurrence rate was 0.97%, complication rate was 3.81% and mean postoperative hospital stay was 5.6 days. Conclusions: VATS treatment of spontaneous pneumothorax is better than open chest surgery and also superior than conservative therapy

  9. Spontaneous Dissection of the Superior Mesenteric Artery

    International Nuclear Information System (INIS)

    Sheldon, Patrick J.; Esther, James B.; Sheldon, Elana L.; Sparks, Steven R.; Brophy, David P.; Oglevie, Steven B.

    2001-01-01

    Spontaneous dissection of the superior mesenteric artery (SMA) is a rare occurrence, especially when not associated with aortic dissection. Currently, only 28 cases appear to have been reported. Due to the scarcity of cases in the literature, the natural history of isolated, spontaneous SMA dissection is unclear. CT has been reported to be useful for the initial diagnosis of SMA dissection [2-5]. We present two recent cases of spontaneous SMA dissection in which enhanced spiral CT was instrumental in following the disease process and guiding clinical decision making

  10. Altered spontaneous brain activity in patients with acute spinal cord injury revealed by resting-state functional MRI.

    Directory of Open Access Journals (Sweden)

    Ling Zhu

    Full Text Available Previous neuroimaging studies have provided evidence of structural and functional reorganization of brain in patients with chronic spinal cord injury (SCI. However, it remains unknown whether the spontaneous brain activity changes in acute SCI. In this study, we investigated intrinsic brain activity in acute SCI patients using a regional homogeneity (ReHo analysis based on resting-state functional magnetic resonance imaging.A total of 15 patients with acute SCI and 16 healthy controls participated in the study. The ReHo value was used to evaluate spontaneous brain activity, and voxel-wise comparisons of ReHo were performed to identify brain regions with altered spontaneous brain activity between groups. We also assessed the associations between ReHo and the clinical scores in brain regions showing changed spontaneous brain activity.Compared with the controls, the acute SCI patients showed decreased ReHo in the bilateral primary motor cortex/primary somatosensory cortex, bilateral supplementary motor area/dorsal lateral prefrontal cortex, right inferior frontal gyrus, bilateral dorsal anterior cingulate cortex and bilateral caudate; and increased ReHo in bilateral precuneus, the left inferior parietal lobe, the left brainstem/hippocampus, the left cingulate motor area, bilateral insula, bilateral thalamus and bilateral cerebellum. The average ReHo values of the left thalamus and right insula were negatively correlated with the international standards for the neurological classification of spinal cord injury motor scores.Our findings indicate that acute distant neuronal damage has an immediate impact on spontaneous brain activity. In acute SCI patients, the ReHo was prominently altered in brain regions involved in motor execution and cognitive control, default mode network, and which are associated with sensorimotor compensatory reorganization. Abnormal ReHo values in the left thalamus and right insula could serve as potential biomarkers for

  11. Magnetic biosorbent for removal of uranyl ions

    International Nuclear Information System (INIS)

    Yamamura, Amanda P.G.; Yamaura, Mitiko; Costa, Caroline H.

    2009-01-01

    In this work magnetic biosorbent, which consisted of sugarcane bagasse as polymeric matrix with magnetite nanoparticles, was prepared. This magnetic composite has the purpose to remove uranyl ions from aqueous effluents. The magnetite was synthetized by simultaneous precipitation by addition a solution of NaOH to the aqueous solution containing Fe2+ and Fe3+. This magnetic bagasse biosorbent have presented superparamagnetic properties, that is, it have showed a high magnetization of saturation without hysteresis. The magnetic biosorbent was utilized to remove uranyl ions from water. Radioactive uranium waste is generated in hospitals, universities and it is used as fuel for nuclear power plants. Variables of adsorption process of uranyl ions by magnetic biosorbent in nitric solutions were investigated, such as, time required for the uranium-magnetic bagasse biosorbent equilibrium in the interval from 20 to 90 min, pH in the intervals from 2 to 5 and 10, stirring speed from 240 to 500 r.p.m. and biosorbent dose from 2 to 25 g.L-1 were investigated. Equilibrium isotherm was verified according to the Langmuir and Freundlich adsorption isotherm models. The highest adsorption capacity reached 17 mg.g-1. The Gibbs free energy indicated to be spontaneous adsorption. This work updates the paper was presented on the 2007 INAC.

  12. Endometriosis-related spontaneous diaphragmatic rupture.

    Science.gov (United States)

    Triponez, Frédéric; Alifano, Marco; Bobbio, Antonio; Regnard, Jean-François

    2010-10-01

    Non-traumatic, spontaneous diaphragmatic rupture is a rare event whose pathophysiology is not known. We report the case of endometriosis-related spontaneous rupture of the right diaphragm with intrathoracic herniation of the liver, gallbladder and colon. We hypothesize that the invasiveness of endometriotic tissue caused diaphragm fragility, which finally lead to its complete rupture without traumatic event. The treatment consisted of a classical management of diaphragmatic rupture, with excision of the endometriotic nodule followed by medical ovarian suppression for six months.

  13. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... times as often as men; in PPMS, the number of women and men are approximately equal. RRMS ...

  14. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Living Well with MS Diet, Exercise & Healthy Behaviors Emotional Well-Being Spiritual Well-Being Cognitive Health Work, ... MS Anesthesia and Surgery Managing Your MS d Emotional Well-Being Mood Changes d Spiritual Well-Being ...

  15. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... of Distinction Lawry Circle Circle of Influence d Planned Giving d Other Ways to Give Donate by ...

  16. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Trials in MS Wellness and Lifestyle Research Diet Vitamin D How and Why Do Scientists Share Results ... The National MS Society is Here to Help Need More Information? We Are Here Our MS Navigators ...

  17. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... Community at MSconnection.org Join a Local Support Group Peer Connections: One-on-One Edward M. Dowd ...

  18. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disease T Cells d What Causes MS? Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS ... Review of Society's Research Programs d Careers d Leadership Board of Directors Senior Leadership Team Founder Sylvia ...

  19. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... working effectively. How does RRMS differ from progressive types of MS? While RRMS is defined by attacks ... Pinterest MS Connection About the Society Vision Careers Leadership Cultural Values Financials News Press Room MS Prevalence ...

  20. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Room Events at a Glance MS the Disease Public Service Announcements In the News Archives d MS ... For Professionals Researchers Physicians Nurses Rehabilitation Professionals Mental Health Professionals Health and Wellness Professionals What Is MS? ...

  1. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Disproved Theories Viruses Clusters d Who Gets MS? Pediatric MS African Americans Hispanics & Latino/as d Multiple ... Questions to Ask d Resources for Specific Populations Pediatric MS Support Veterans with Multiple Sclerosis d Find ...

  2. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Conditions to Rule Out For Clinicians Treating MS Comprehensive Care Find an MS Care Provider Medications Managing ... ADEM) d For Clinicians d Treating MS d Comprehensive Care Developing a Healthcare Team Make the Most ...

  3. Magnetic memory signals variation induced by applied magnetic field and static tensile stress in ferromagnetic steel

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Haihong, E-mail: huanghaihong@hfut.edu.cn; Yang, Cheng; Qian, Zhengchun; Han, Gang; Liu, Zhifeng

    2016-10-15

    Stress can induce a spontaneous magnetic field in ferromagnetic steel under the excitation of geomagnetic field. In order to investigate the impact of applied magnetic field and tensile stress on variation of the residual magnetic signals on the surface of ferromagnetic materials, static tensile tests of Q235 structural steel were carried out, with the normal component of the residual magnetic signals, H{sub p}(y), induced by applied magnetic fields with different intensities measured through the tensile tests. The H{sub p}(y), its slope coefficient K{sub S} and maximum gradient K{sub max} changing with the applied magnetic field H and tensile stress were observed. Results show that the magnitude of H{sub p}(y) and its slope coefficient K{sub S} increase linearly with the increase of stress in the elastic deformation stage. Under yield stress, H{sub p}(y) and K{sub S} reach its maximum, and then decrease slightly with further increase of stress. Applied magnetic field affects the magnitude of H{sub p}(y) instead of changing the signal curve′s profile; and the magnitude of H{sub p}(y), K{sub S}, K{sub max} and the change rate of K{sub S} increase with the increase of applied magnetic field. The phenomenon is also discussed from the viewpoint of magnetic charge in ferromagnetic materials. - Highlights: • We investigated how applied magnetic field and tensile stress impact H{sub p}(y) signals. • Magnitude of H{sub p}(y), K{sub S} and K{sub max} increase with the increase of applied magnetic field. • Both applied magnetic field and tensile stress impact material magnetic permeability. • Applied magnetic field can help to evaluate the stress distribution of components.

  4. Simultaneous analysis of 17 diuretics in dietary supplements by HPLC and LC-MS/MS.

    Science.gov (United States)

    Woo, H; Kim, J W; Han, K M; Lee, J H; Hwang, I S; Lee, J H; Kim, J; Kweon, S J; Cho, S; Chae, K R; Han, S Y; Kim, J

    2013-01-01

    In order to test health foods for illegally added diuretics for weight loss, we developed simple, rapid, selective, and sensitive methods using HPLC and LC-MS/MS for the simultaneous analysis of 17 diuretics in dietary supplements. HPLC conditions were set with a Capcell-pak C18, using a mobile phase consisting of gradient conditions, UV detection at 254 nm and validated for linearity (r(2)> 0.999), precision (CV ≤ 3%), recoveries (90.4-102.8%) and reproducibility. Identification and quantification of 17 diuretics were accomplished by ion-spray LC-MS/MS using multiple reaction monitoring (MRM). The chromatographic separation was carried out under the reversed-phase mechanism on an HSS-T3 column. The LC-MS/MS method was validated for linearity (r(2)> 0.99) and precision (CV Diuretics were not detected in all samples. Extraction recovery was also investigated and the extraction recoveries in different formulations were from 88% to 110% and from 81% to 116% using HPLC and LC-MS/MS, respectively. There was no significant difference in recoveries in the type of dietary supplements. Based on this result, the developed methods to monitor illegal drug adulterations in dietary supplements using HPLC and LC-MS/MS are simple, fast and reliable. Therefore, it is applicable to routine drug-adulteration screening.

  5. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Viruses Clusters d Who Gets MS? Pediatric MS African Americans Hispanics & Latino/as d Multiple Sclerosis FAQs d ... Diet & Nutrition Exercise Heat & Temperature Sensitivity Sleep Vaccinations Women's Health Unhealthy Habits Managing MS and Another Condition ...

  6. A comparative study of magnetic field induced meta-magnetic transition in nanocrystalline and bulk Pr0.65(Ca0.7Sr0.3)0.35MnO3 compound

    Science.gov (United States)

    Saha, Suvayan; Das, Kalipada; Bandyopadhyay, Sudipta; Das, I.

    2017-06-01

    In our present study we highlight the observations of external magnetic field induced sharp meta-magnetic transition in polycrystalline bulk as well as nanocrystalline form of Pr0.65(Ca0.7Sr0.7)0.35MnO3 compound. Interestingly, such behavior persists in the nanoparticles regardless of the disorder broadened transition. However, higher magnetic field is required for nanoparticles having average particle size ∼40 nm for such meta-magnetic transition, which differs from the general trends of the pure charge ordered nano materials. The interfacial strain between the different magnetic domains plays the important role in magnetic isothermal properties of nanoparticles, when the samples are cooled down in different cooling field. Additionally, both the bulk and nanoparticle compounds exhibit spontaneous phase separation and significantly large magnetoresistance at the low temperature region due to the melting of charge ordered fraction.

  7. Detection of target phonemes in spontaneous and read speech.

    Science.gov (United States)

    Mehta, G; Cutler, A

    1988-01-01

    Although spontaneous speech occurs more frequently in most listeners' experience than read speech, laboratory studies of human speech recognition typically use carefully controlled materials read from a script. The phonological and prosodic characteristics of spontaneous and read speech differ considerably, however, which suggests that laboratory results may not generalise to the recognition of spontaneous speech. In the present study listeners were presented with both spontaneous and read speech materials, and their response time to detect word-initial target phonemes was measured. Responses were, overall, equally fast in each speech mode. However, analysis of effects previously reported in phoneme detection studies revealed significant differences between speech modes. In read speech but not in spontaneous speech, later targets were detected more rapidly than targets preceded by short words. In contrast, in spontaneous speech but not in read speech, targets were detected more rapidly in accented than in unaccented words and in strong than in weak syllables. An explanation for this pattern is offered in terms of characteristic prosodic differences between spontaneous and read speech. The results support claims from previous work that listeners pay great attention to prosodic information in the process of recognising speech.

  8. Spontaneous CP violation on the lattice

    CERN Document Server

    Laine, Mikko

    2000-01-01

    At finite temperatures around the electroweak phase transition, the thermodynamics of the MSSM can be described by a three-dimensional two Higgs doublet effective theory. This effective theory has a phase where CP is spontaneously violated. We study spontaneous CP violation with non-perturbative lattice simulations, and analyse whether one could end up in this phase for any physical MSSM parameter values.

  9. Spontaneous pneumothorax associated with lung cancer

    International Nuclear Information System (INIS)

    Sung, Dong Wook; Jung, Seung Hyae; Yoon, Yup; Lim, Jae Hoon; Cho, Kyu Soek; Yang, Moon Ho

    1991-01-01

    Spontaneous pneumothorax is a rare manifestation of lung cancer. Eight cases of pneumothorax found in 1648 patients with lung cancer from 1979-1990 are reported. Histopathologic types of cancer were adenocarcinoma in three cases, squamous cell carcinoma in two cases, bronchioloalveolar carcinoma in two cases, and metastatic renal cell carcinoma in one case. The primary tumor mass was not found even after thoracotomy in two cases. Spontaneous pneumothorax occurred on the ipsilateral side of the cancer. All the patients were more than 40 years old with a history of smoking 1-2 packs a day for 20 to 50 years, and had chronic lung diseases. The authors emphasize that bronchogenic carcinoma may be one of the causes of spontaneous pneumothorax in appropriate clinical settings

  10. Surface magnetization of the Ising ferromagnet in semi-infinite cubic lattice: renormalization group approach

    International Nuclear Information System (INIS)

    Chame, A.M.N.; Tsallis, C.

    1988-01-01

    The behaviour of the spontaneous surface and bulk magnetizations as function of the temperature for the Ising ferromagnet in a semi-infinitre cubic lattice for various ratios JS/JB (JS and JB are the surface and bulk coupling constants, respectively), is studied. The extraordinary transition where the surface maintains its magnetization as the bulk disorders, was study, in particular; a discontinuity on the first derivative of the surface magnetization at the bulk transition temperature was found. The criticality of the system (universality classes, critical exponents and amplitudes) is discussed. An unexpected slight lack of monotonicity of the surface magnetization as a function of JS/JB for JS/JB [pt

  11. Spontaneous generation in medieval Jewish philosophy and theology.

    Science.gov (United States)

    Gaziel, Ahuva

    2012-01-01

    The concept of life forms emerging from inanimate matter--spontaneous generation--was widely accepted until the nineteenth century. Several medieval Jewish scholars acknowledged this scientific theory in their philosophical and religious contemplations. Quite interestingly, it served to reinforce diverse, or even opposite, theological conclusions. One approach excluded spontaneously-generated living beings form the biblical account of creation or the story of the Deluge. Underlying this view is an understanding that organisms that generate spontaneously evolve continuously in nature and, therefore, do not require divine intervention in their formation or survival during disastrous events. This naturalistic position reduces the miraculous dimension of reality. Others were of the opinion that spontaneous generation is one of the extraordinary marvels exhibited in this world and, accordingly, this interpretation served to accentuate the divine aspect of nature. References to spontaneous generation also appear in legal writings, influencing practical applications such as dietary laws and actions forbidden on the Sabbath.

  12. Magnetic Geared Radial Axis Vertical Wind Turbine for Low Velocity Regimes

    Directory of Open Access Journals (Sweden)

    Wei Wei Teow

    2018-01-01

    Full Text Available In the 21st century, every country is seeking an alternative source of energy especially the renewable sources. There are considerable developments in the wind energy technology in recent years and in more particular on the vertical axis wind turbine (VAWT as they are modular, less installation cost and portable in comparison with that of the horizontal axis wind turbine (HAWT systems. The cut-in speed of a conventional wind turbine is 3.5 m/s to 5 m/s. Mechanical geared generators are commonly found in wind technology to step up power conversion to accommodate the needs of the generator. Wind turbine gearboxes suffer from overload problem and frequent maintenance in spite of the high torque density produced. However, an emerging alternative to gearing system is Magnetic Gear (MG as it offers significant advantages such as free from maintenance and inherent overload protection. In this project, numerical analysis is done on designed magnetic gear greatly affects the performance of the generator in terms of voltage generation. Magnetic flux density is distributed evenly across the generator as seen from the uniform sinusoidal output waveform. Consequently, the interaction of the magnetic flux of the permanent magnets has shown no disturbance to the output of the generator as the voltage generated shows uniform waveform despite the rotational speed of the gears. The simulation is run at low wind speed and the results show that the generator starts generating a voltage of 240 V at a wind speed of 1.04 m/s. This shows great improvement in the operating capability of the wind turbine.

  13. MS-SQL data base programming

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Chang Bae; Kim, Nam Jung; Lee, Hyeong Gyo

    2002-07-15

    This is about MS-SQL data base programming which is divided into thirteen chapters. The contents of this book are to understand MS-SQL 2000 DBMS with its composition, new function and history of MS-SQL, to learn conception of data base, install, run and closing of MS-SQL 2000 DBMS, to deal with the basic of MS-SQL DBMS, to handle the intermediate level of MS-SQL DBMS, to deal with MS-SQL DBMS in advanced level, to practice query like changing data base and checking of data lists, function on its use and data diff, get date, date add, char, upper and system function, set-up of MS-SQL ODBC, constructing of web server of windows 2000, web programming using visual studio.net.making board and making reference room.

  14. MS-SQL data base programming

    International Nuclear Information System (INIS)

    Noh, Chang Bae; Kim, Nam Jung; Lee, Hyeong Gyo

    2002-07-01

    This is about MS-SQL data base programming which is divided into thirteen chapters. The contents of this book are to understand MS-SQL 2000 DBMS with its composition, new function and history of MS-SQL, to learn conception of data base, install, run and closing of MS-SQL 2000 DBMS, to deal with the basic of MS-SQL DBMS, to handle the intermediate level of MS-SQL DBMS, to deal with MS-SQL DBMS in advanced level, to practice query like changing data base and checking of data lists, function on its use and data diff, get date, date add, char, upper and system function, set-up of MS-SQL ODBC, constructing of web server of windows 2000, web programming using visual studio.net.making board and making reference room.

  15. Magnetic properties of carbonyl iron particles in magnetorheological fluids

    International Nuclear Information System (INIS)

    Gorodkin, S R; James, R O; Kordonski, W I

    2009-01-01

    Knowledge of the magnetic properties of dispersed magnetic particles is a prerequisite to the design an MR fluid with desired performance. A term specific susceptibility is introduced for characterization of particle susceptibility. The study was performed with the Bartington MS2B magnetic susceptibility system on small samples volume. Specific magnetic susceptibility of iron particles was found to be a linear function of median particle size. Structural change in the fluid, including particle organization, led to susceptibility drift and may affect fluid performance. It was shown that susceptibility data can be used for evaluation of the concentration of carbonyl iron particles in MR fluids.

  16. Spontaneous low-frequency oscillations in cerebral vessels

    DEFF Research Database (Denmark)

    Schytz, Henrik W; Hansson, Andreas; Phillip, Dorte

    2010-01-01

    ). Analysis of CA by measurement of spontaneous oscillations in the low-frequency spectrum in cerebral vessels might be a useful tool for assessing risk and investigating different treatment strategies in carotid artery disease (CAD) and stroke. We reviewed studies exploring spontaneous oscillations...

  17. Analytical Method Details (MS): SE2_MS3 [Metabolonote[Archive

    Lifescience Database Archive (English)

    Full Text Available 00.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1)., Rejected mass=284.2000;300.2000;328.2000;344.2000;372.2000;388.2000;416.3000;432.3000;460.0000. ...

  18. Helical undulator based on partial redistribution of uniform magnetic field

    Directory of Open Access Journals (Sweden)

    N. Balal

    2017-12-01

    Full Text Available A new type of helical undulator based on redistribution of magnetic field of a solenoid by ferromagnetic helix has been proposed and studied both in theory and experiment. Such undulators are very simple and efficient for promising sources of coherent spontaneous THz undulator radiation from dense electron bunches formed in laser-driven photo-injectors.

  19. Gadolinium enhancement of spinal subdural collection on magnetic resonance imaging after lumbar puncture

    International Nuclear Information System (INIS)

    Teksam, Mehmet; Casey, Sean O.; McKinney, Alexander; Michel, Eduard; Truwit, Charles L.

    2003-01-01

    We report a 35-year-old male with an unusual contrast-enhancing sterile spinal subdural collection on magnetic resonance imaging (MRI), apparently occurring as a complication of lumbar puncture. Follow-up MRI after 4 weeks demonstrated spontaneous resolution of the collection without intervening treatment. (orig.)

  20. Spontaneous rupture of vaginal enterocele

    DEFF Research Database (Denmark)

    Svendsen, J H; Galatius, H; Hansen, P K

    1985-01-01

    Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission.......Spontaneous rupture of an enterocele is a rare complication. Only 24 cases including the present case have been reported in the literature. The patients were elderly and had had at least one vaginal operation. The patients were remarkably unaffected symptomatically on admission....

  1. Relapsing-Remitting MS (RRMS)

    Medline Plus

    Full Text Available ... Treating MS d Comprehensive Care Developing a Healthcare Team Make the Most of Your Doctor Visits Advance Medical Directives d Find an MS Care Provider Partners in MS Care d Managing Relapses Plasmapheresis d Rehabilitation Functional Electrical Stimulation (FES) ...

  2. Magnetic Fields of Neutron Stars

    Indian Academy of Sciences (India)

    Sushan Konar

    2017-09-12

    Sep 12, 2017 ... the material properties of the region where currents supporting the .... 1The evolution of magnetic field in neutron stars, in particular, the question of .... −10, 10. −9, 10. −8. M⊙/yr respec- tively. See Konar & Bhattacharya (1997) for details. Peq ≃ 1.9 ms ..... ported by a grant (SR/WOS-A/PM-1038/2014) from.

  3. MS Based Metabonomics

    Energy Technology Data Exchange (ETDEWEB)

    Want, Elizabeth J.; Metz, Thomas O.

    2010-03-01

    Metabonomics is the latest and least mature of the systems biology triad, which also includes genomics and proteomics, and has its origins in the early orthomolecular medicine work pioneered by Linus Pauling and Arthur Robinson. It was defined by Nicholson and colleagues in 1999 as the quantitative measurement of perturbations in the metabolite complement of an integrated biological system in response to internal or external stimuli, and is often used today to describe many non-global types of metabolite analyses. Applications of metabonomics are extensive and include toxicology, nutrition, pharmaceutical research and development, physiological monitoring and disease diagnosis. For example, blood samples from millions of neonates are tested routinely by mass spectrometry (MS) as a diagnostic tool for inborn errors of metabolism. The metabonome encompasses a wide range of structurally diverse metabolites; therefore, no single analytical platform will be sufficient. Specialized sample preparation and detection techniques are required, and advances in NMR and MS technologies have led to enhanced metabonome coverage, which in turn demands improved data analysis approaches. The role of MS in metabonomics is still evolving as instrumentation and software becomes more sophisticated and as researchers realize the strengths and limitations of current technology. MS offers a wide dynamic range, high sensitivity, and reproducible, quantitative analysis. These attributes are essential for addressing the challenges of metabonomics, as the range of metabolite concentrations easily exceeds nine orders of magnitude in biofluids, and the diversity of molecular species ranges from simple amino and organic acids to lipids and complex carbohydrates. Additional challenges arise in generating a comprehensive metabolite profile, downstream data processing and analysis, and structural characterization of important metabolites. A typical workflow of MS-based metabonomics is shown in Figure

  4. Density functional theory investigation of the magnetism of 1,3,5-trithia-2,4,6-triazapentalenyl

    International Nuclear Information System (INIS)

    Zou Weidong; Liu Zuli; Wu Minghu; Yao Kailun

    2004-01-01

    An accurate full-potential density-functional method is used to study the mechanism of the origin of magnetism and of the magnetic interactions in 1,3,5-trithia-2,4,6-triazapentalenyl (TTTA). The results shown that because of the spin polarization effect and the spin exchange coupling interactions of these atoms, the net spin magnetic moment is formed in the molecule and the spontaneous magnetic moments for the TTTA mainly come from N 1 , S 1 , S 2 atoms and the N 2 , N 3 and S 3 atoms give a little contribution to the magnetism. Our results also revealed that there exists ferromagnetic interaction in the intramolecular of TTTA

  5. Spontaneous emission spectra and simulating multiple spontaneous generation coherence in a five-level atomic medium

    International Nuclear Information System (INIS)

    Li Jiahua; Liu Jibing; Qi Chunchao; Chen Aixi

    2006-01-01

    We investigate the features of the spontaneous emission spectra in a coherently driven cold five-level atomic system by means of a radio frequency (rf) or microwave field driving a hyperfine transition within the ground state. It is shown that a few interesting phenomena such as spectral-line narrowing, spectral-line enhancement, spectral-line suppression, and spontaneous emission quenching can be realized by modulating the frequency and intensity of the rf-driving field in our system. In the dressed-state picture of the coupling and rf-driving fields, we find that this coherently driven atomic system has three close-lying levels so that multiple spontaneously generated coherence (SGC) arises. Our considered atomic model can be found in real atoms, such as rubidium or sodium, so a corresponding experiment can be done to observe the expected phenomena related to SGC reported by Fountoulakis et al. [Phys. Rev. A 73, 033811 (2006)], since no rigorous conditions are required

  6. Rare-earth magnet applications in energy conversion

    International Nuclear Information System (INIS)

    Tripathi, K.C.

    1998-01-01

    In recent years there has been considerable progress in the field of development and variety of new applications of rare-earth and rare-earth transition metal magnets. High energy content Nd-Fe-B magnet system which competes with superconducting magnets is very promising for the use in energy conversion machines, levitation systems, magnetic resonance investigation and other magnetic applications. Energy conversion machines such as motors and generators are of interest in this context. Motor converts electrical energy into mechanical energy using permanent magnets and ferromagnetic materials as its components. Electric generator converts mechanical energy into electricity using permanent magnets and ferromagnetic material. In both cases symmetry and symmetry breaking play an important role. Symmetry exists above curie temperature, as temperature is lowered symmetry is broken due to spontaneous magnetisation. Author and coworkers developed some new and highest efficiency, permanent magnet based, electronically controlled, dynamically synchronised pulsed dc linear and rotational motors which are briefly described here. Based on such experience and considering field interactions inside material under dynamical conditions and special geometrical situations, order-disorder processes, symmetry breaking and energy transfer on the basis of manifold aspects as a cooperative many body interaction, thermal fluctuations, zero-point energy, dissipation of energy, entropy exchange are discussed in context of conversion of environmental heat into electricity as suggested by Tripathi earlier. (orig.)

  7. A new class of spontaneously polarized materials

    DEFF Research Database (Denmark)

    Field, David; Plekan, Oksana; Cassidy, Andrew

    2011-01-01

    Very large electric fields form spontaneously within films of seemingly prosaic chemicals such as nitrous oxide or propane.We describe how the discovery of this unexpected phenomenon took place and how we attempt to understand the nature of the new class of spontaneously polarized materials...

  8. Spontaneous rupture of choledochal cyst: case report

    International Nuclear Information System (INIS)

    Shin, Ho Seob; Nam, Kyung Jin; Lee, Jin Hwa; Kim, Chan Sung; Choi, Jong Cheol; Oh, Jong Young

    2002-01-01

    Spontaneous rupture of a choledochal cyst leading to biliary peritonitis is a rare complication which can be fatal if not promptly diagnosed. The authors report the ultrasound and CT findings of two cases of spontaneous choledochal cystic rupture and the biliary peritonitis which ensued

  9. Spontaneous rupture of choledochal cyst: case report

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ho Seob; Nam, Kyung Jin; Lee, Jin Hwa; Kim, Chan Sung; Choi, Jong Cheol; Oh, Jong Young [Dong-a University College of Medicine, Pusan (Korea, Republic of)

    2002-11-01

    Spontaneous rupture of a choledochal cyst leading to biliary peritonitis is a rare complication which can be fatal if not promptly diagnosed. The authors report the ultrasound and CT findings of two cases of spontaneous choledochal cystic rupture and the biliary peritonitis which ensued.

  10. Magnetic poly(D,L-lactide) nanoparticles loaded with aliskiren: A promising tool for hypertension treatment

    International Nuclear Information System (INIS)

    Antal, Iryna; Kubovcikova, Martina; Zavisova, Vlasta; Koneracka, Martina; Pechanova, Olga; Barta, Andrej; Cebova, Martina; Antal, Vitaliy; Diko, Pavel; Zduriencikova, Martina; Pudlak, Michal; Kopcansky, Peter

    2015-01-01

    In this study anti-hypertensive drug called aliskiren was encapsulated in magnetic poly(D,L-lactide) nanoparticles by the modified nanoprecipitation method. The effect of magnetite and drug concentrations on the size distribution and zeta potential of polymer nanoparticles was investigated. The optimized loadings were as follows: theoretical magnetite loading was 20 mg/100 mg polymer nanoparticles and aliskiren was encapsulated in magnetic poly(D,L-lactide) nanoparticles at theoretical loading 0.6 mg aliskiren/100 mg magnetic polymer nanoparticles. The physicochemical characteristics of nanoparticles were studied, with spherical shape of nanoparticles sized between 58 and 227 nm being one of the observed results. Differential scanning calorimetry and infrared spectroscopy confirmed that aliskiren was successfully identified in the magnetic poly(D,L-lactide) nanoparticles. The in vivo experiments indicated that encapsulated aliskiren decreased blood pressure of the studied male spontaneously hypertensive rat even more significantly than common administered drug. - Highlights: • Anti-hypertensive drug called aliskiren was encapsulated in magnetic poly(D,L-lactide) nanoparticles by modified nanoprecipitation method. • The optimisation of magnetite and drug loading with regard to the size distribution and zeta potential was investigated. • The physicochemical characteristics of nanoparticles were studied by different techniques. • The in vivo experiments indicated that encapsulated aliskiren decreased blood pressure of the studied male spontaneously hypertensive rat even more significantly than common administered drug

  11. Magnetic poly(D,L-lactide) nanoparticles loaded with aliskiren: A promising tool for hypertension treatment

    Energy Technology Data Exchange (ETDEWEB)

    Antal, Iryna, E-mail: iryna.antal@saske.sk [Institute of Experimental Physics, SAS, Watsonova 47, 040 01 Kosice (Slovakia); Kubovcikova, Martina; Zavisova, Vlasta; Koneracka, Martina [Institute of Experimental Physics, SAS, Watsonova 47, 040 01 Kosice (Slovakia); Pechanova, Olga; Barta, Andrej; Cebova, Martina [Institute of Normal and Pathological Physiology, SAS, Bratislava (Slovakia); Antal, Vitaliy; Diko, Pavel [Institute of Experimental Physics, SAS, Watsonova 47, 040 01 Kosice (Slovakia); Zduriencikova, Martina [Cancer Research Institute, SAS, Bratislava (Slovakia); Pudlak, Michal; Kopcansky, Peter [Institute of Experimental Physics, SAS, Watsonova 47, 040 01 Kosice (Slovakia)

    2015-04-15

    In this study anti-hypertensive drug called aliskiren was encapsulated in magnetic poly(D,L-lactide) nanoparticles by the modified nanoprecipitation method. The effect of magnetite and drug concentrations on the size distribution and zeta potential of polymer nanoparticles was investigated. The optimized loadings were as follows: theoretical magnetite loading was 20 mg/100 mg polymer nanoparticles and aliskiren was encapsulated in magnetic poly(D,L-lactide) nanoparticles at theoretical loading 0.6 mg aliskiren/100 mg magnetic polymer nanoparticles. The physicochemical characteristics of nanoparticles were studied, with spherical shape of nanoparticles sized between 58 and 227 nm being one of the observed results. Differential scanning calorimetry and infrared spectroscopy confirmed that aliskiren was successfully identified in the magnetic poly(D,L-lactide) nanoparticles. The in vivo experiments indicated that encapsulated aliskiren decreased blood pressure of the studied male spontaneously hypertensive rat even more significantly than common administered drug. - Highlights: • Anti-hypertensive drug called aliskiren was encapsulated in magnetic poly(D,L-lactide) nanoparticles by modified nanoprecipitation method. • The optimisation of magnetite and drug loading with regard to the size distribution and zeta potential was investigated. • The physicochemical characteristics of nanoparticles were studied by different techniques. • The in vivo experiments indicated that encapsulated aliskiren decreased blood pressure of the studied male spontaneously hypertensive rat even more significantly than common administered drug.

  12. Spontaneous symmetry breaking and its cosmological consequences

    International Nuclear Information System (INIS)

    Kobzarev, I.Yu.

    1975-01-01

    The concept of symmetry and of the spontaneous symmetry breaking are presented in popular form as applied to quantum physics. Though the presence of the spontaneous symmetry breaking is not proved directly for interactions of elementary particles, on considering the hypothesis of its presence as applied to the hot Universe theory a possibility of obtaining rather uncommon cosmological consequences is discussed. In particular, spontaneous symmetry breaking of vacuum and the rather hot Universe lead necessarily to the presence of the domain structure of the Universe with the surfase energy at the domain interface in the form of a real physical object

  13. Shared risk aversion in spontaneous and induced abortion.

    Science.gov (United States)

    Catalano, Ralph; Bruckner, Tim A; Karasek, Deborah; Adler, Nancy E; Mortensen, Laust H

    2016-05-01

    Does the incidence of spontaneous abortion correlate positively over conception cohorts with the incidence of non-clinically indicated induced abortion as predicted by shared risk aversion? We find that the number of spontaneous and non-clinically indicated induced abortions correlates in conception cohorts, suggesting that risk aversion affects both the conscious and non-conscious mechanisms that control parturition. Much literature speculates that natural selection conserved risk aversion because the trait enhanced Darwinian fitness. Risk aversion, moreover, supposedly influences all decisions including those that individuals can and cannot report making. We argue that these circumstances, if real, would manifest in conscious and non-conscious decisions to invest in prospective offspring, and therefore affect incidence of induced and spontaneous abortion over time. Using data from Denmark, we test the hypothesis that monthly conception cohorts yielding unexpectedly many non-clinically indicated induced abortions also yield unexpectedly many spontaneous abortions. The 180 month test period (January 1995 through December 2009), yielded 1 351 800 gestations including 156 780 spontaneous as well as 233 280 induced abortions 9100 of which were clinically indicated. We use Box-Jenkins transfer functions to adjust the incidence of spontaneous and non-clinically indicated induced abortions for autocorrelation (including seasonality), cohort size, and fetal as well as gestational anomalies over the 180-month test period. We use cross-correlation to test our hypothesized association. We find a positive association between spontaneous and non-clinically indicated induced abortions. This suggests, consistent with our theory, that mothers of conception cohorts that yielded more spontaneous abortions than expected opted more frequently than expected for non-clinically indicated induced abortion. Limitations of our work include that even the world's best registration system

  14. Group theory of spontaneous symmetry breaking

    International Nuclear Information System (INIS)

    Ghaboussi, F.

    1987-01-01

    The connection between the minimality of the Higgs field potential and the maximal little groups of its representation obtained by spontaneous symmetry breaking is analyzed. It is shown that for several representations the lowest minimum of the potential is related to the maximal little group of those representations. Furthermore, a practical necessity criterion is given for the representation of the Higgs field needed for spontaneous symmetry breaking

  15. LC-MS-MS identification of drug metabolites obtained by metalloporphyrin mediated oxidation

    Directory of Open Access Journals (Sweden)

    Maurin Andrea J. M.

    2003-01-01

    Full Text Available In this paper we report the application of liquid chromatography-mass spectrometry (LC-MS-MS to the identification of the products formed by oxidation of albendazole and disopyramide with metalloporphyrins in dichloroethane, using iodosylbenzene as an oxygen donor. Our results show that LC-MS-MS is a powerful tool to study the in vitro metabolism of drugs, allowing the identification of known and unknown metabolites. In addition, it was observed that the catalyst system used resulted in the formation of the same metabolites as obtained in vivo, although for disopyramide other products were also observed.

  16. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.

    Science.gov (United States)

    Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana

    2016-09-01

    DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.

  17. Spontaneous polyploidization in cucumber.

    Science.gov (United States)

    Ramírez-Madera, Axel O; Miller, Nathan D; Spalding, Edgar P; Weng, Yiqun; Havey, Michael J

    2017-07-01

    This is the first quantitative estimation of spontaneous polyploidy in cucumber and we detected 2.2% polyploids in a greenhouse study. We provide evidence that polyploidization is consistent with endoreduplication and is an on-going process during plant growth. Cucumber occasionally produces polyploid plants, which are problematic for growers because these plants produce misshaped fruits with non-viable seeds. In this study, we undertook the first quantitative study to estimate the relative frequency of spontaneous polyploids in cucumber. Seeds of recombinant inbred lines were produced in different environments, plants were grown in the field and greenhouse, and flow cytometry was used to establish ploidies. From 1422 greenhouse-grown plants, the overall relative frequency of spontaneous polyploidy was 2.2%. Plants possessed nuclei of different ploidies in the same leaves (mosaic) and on different parts of the same plant (chimeric). Our results provide evidence of endoreduplication and polysomaty in cucumber, and that it is an on-going and dynamic process. There was a significant effect (p = 0.018) of seed production environment on the occurrence of polyploid plants. Seed and seedling traits were not accurate predictors of eventual polyploids, and we recommend that cucumber producers rogue plants based on stature and leaf serration to remove potential polyploids.

  18. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  19. Children's Spontaneous Vocalisations during Play: Aesthetic Dimensions

    Science.gov (United States)

    Countryman, June; Gabriel, Martha; Thompson, Katherine

    2016-01-01

    This paper explores the phenomenon of spontaneous vocalisations in the self-chosen, unstructured outdoor play of children aged 3-12. Spontaneous vocalisations encompass the whole range of children's unprompted, natural, expressive vocal soundings beyond spoken language. Non-participant observations at childcare centres and on elementary school…

  20. Modulation of Magnetic Properties at the Nanometer Scale in Continuously Graded Ferromagnets

    Directory of Open Access Journals (Sweden)

    Lorenzo Fallarino

    2018-02-01

    Full Text Available Ferromagnetic alloy materials with designed composition depth profiles provide an efficient route for the control of magnetism at the nanometer length scale. In this regard, cobalt-chromium and cobalt-ruthenium alloys constitute powerful model systems. They exhibit easy-to-tune magnetic properties such as saturation magnetization MS and Curie temperature TC while preserving their crystalline structure over a wide composition range. In order to demonstrate this materials design potential, we have grown a series of graded Co1−xCrx and Co1−wRuw (10 1 ¯ 0 epitaxial thin films, with x and w following predefined concentration profiles. Structural analysis measurements verify the epitaxial nature and crystallographic quality of our entire sample sets, which were designed to exhibit in-plane c-axis orientation and thus a magnetic in-plane easy axis to achieve suppression of magnetostatic domain generation. Temperature and field-dependent magnetic depth profiles have been measured by means of polarized neutron reflectometry. In both investigated structures, TC and MS are found to vary as a function of depth in accordance with the predefined compositional depth profiles. Our Co1−wRuw sample structures, which exhibit very steep material gradients, allow us to determine the localization limit for compositionally graded materials, which we find to be of the order of 1 nm. The Co1−xCrx systems show the expected U-shaped TC and MS depth profiles, for which these specific samples were designed. The corresponding temperature dependent magnetization profile is then utilized to control the coupling along the film depth, which even allows for a sharp onset of decoupling of top and bottom sample parts at elevated temperatures.