WorldWideScience

Sample records for spontaneous electron-hole-pair lifetime

  1. Electron-hole pairs generated in ZrO2 nanoparticle resist upon exposure to extreme ultraviolet radiation

    Science.gov (United States)

    Kozawa, Takahiro; Santillan, Julius Joseph; Itani, Toshiro

    2018-02-01

    Metal oxide nanoparticle resists have attracted much attention as the next-generation resist used for the high-volume production of semiconductor devices. However, the sensitization mechanism of the metal oxide nanoparticle resists is unknown. Understanding the sensitization mechanism is important for the efficient development of resist materials. In this study, the energy deposition in a zirconium oxide (ZrO2) nanoparticle resist was investigated. The numbers of electron-hole pairs generated in a ZrO2 core and an methacrylic acid (MAA) ligand shell upon exposure to 1 mJ cm-2 (exposure dose) extreme ultraviolet (EUV) radiations were theoretically estimated to be 0.16 at most and 0.04-0.17 cm2 mJ-1, respectively. By comparing the calculated distribution of electron-hole pairs with the line-and-space patterns of the ZrO2 nanoparticle resist fabricated by an EUV exposure tool, the number of electron-hole pairs required for the solubility change of the resist films was estimated to be 1.3-2.2 per NP. NP denotes a nanoparticle consisting of a metal oxide core with a ligand shell. In the material design of metal oxide nanoparticle resists, it is important to efficiently use the electron-hole pairs generated in the metal oxide core for the chemical change of ligand molecules.

  2. Transient Melting and Recrystallization of Semiconductor Nanocrystals Under Multiple Electron-Hole Pair Excitation.

    Science.gov (United States)

    Kirschner, Matthew S; Hannah, Daniel C; Diroll, Benjamin T; Zhang, Xiaoyi; Wagner, Michael J; Hayes, Dugan; Chang, Angela Y; Rowland, Clare E; Lethiec, Clotilde M; Schatz, George C; Chen, Lin X; Schaller, Richard D

    2017-09-13

    Ultrafast optical pump, X-ray diffraction probe experiments were performed on CdSe nanocrystal (NC) colloidal dispersions as functions of particle size, polytype, and pump fluence. Bragg peak shifts related to heating and peak amplitude reduction associated with lattice disordering are observed. For smaller NCs, melting initiates upon absorption of as few as ∼15 electron-hole pair excitations per NC on average (0.89 excitations/nm 3 for a 1.5 nm radius) with roughly the same excitation density inducing melting for all examined NCs. Diffraction intensity recovery kinetics, attributable to recrystallization, occur over hundreds of picoseconds with slower recoveries for larger particles. Zincblende and wurtzite NCs revert to initial structures following intense photoexcitation suggesting melting occurs primarily at the surface, as supported by simulations. Electronic structure calculations relate significant band gap narrowing with decreased crystallinity. These findings reflect the need to consider the physical stability of nanomaterials and related electronic impacts in high intensity excitation applications such as lasing and solid-state lighting.

  3. Determination of the electron-hole pair creation energy for semiconductors from the spectral responsivity of photodiodes

    CERN Document Server

    Scholze, F; Kuschnerus, P; Rabus, H; Richter, M; Ulm, G

    2000-01-01

    Ionizing radiation can be detected by the measurement of the charge carriers produced in a detector. The improved semiconductor technology now allows detectors operating near the physical limits of the detector materials to be designed. The mean energy required for producing an electron-hole pair, W, is a material property of the semiconductor. Here, the determination of W from the spectral responsivity of photodiodes is demonstrated. Using spectrally dispersed synchrotron radiation, different types of semiconductor photodiodes have been examined in the UV-, VUV-, and soft X-ray spectral range. Their spectral responsivity was determined with relative uncertainties between 0.4% and 1% using a cryogenic electrical-substitution radiometer as primary detector standard. Results are presented for silicon n-on-p junction photodiodes and for GaAsP/Au Schottky diodes at room temperature. The investigations for silicon covered the complete spectral range from 3 to 1500 eV, yielding a constant value W=(3.66+-0.03) eV fo...

  4. Temperature variation of radiative recombination rate of electron-hole pairs responsible for defect photoluminescence in a-Si:H

    Energy Technology Data Exchange (ETDEWEB)

    Ogihara, C. [Department of Applied Science, Yamaguchi University, Ube (Japan); Morigaki, K. [Department of Electrical and Digital-System Engineering, Hiroshima Institute of Technology, Miyake, Saeki-ku, Hiroshima (Japan)

    2009-05-15

    Lifetime distribution and characteristic lifetime of the defect photoluminescence (PL) in a-Si:H have been obtained by means of frequency resolved spectroscopy at various temperatures in the range of 10-200 K. Temperature variation of the radiative recombination rate has been obtained from the intensities and the characteristic lifetimes. The results obtained for the a-Si:H films as grown and after prolonged illumination have been compared. Thermal quenching of the defect PL becomes more significant after illumination. However the decrease of lifetime with raising temperature becomes less significant after illumination. Increase of the radiative recombination rate with increasing temperature, which is significantly observed above 100 K, becomes less significant after the illumination, indicating that the illumination causes the increase of the density of strongly localised tail states. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  5. Characterization of a quadrant diamond transmission X-ray detector including a precise determination of the mean electron-hole pair creation energy.

    Science.gov (United States)

    Keister, Jeffrey W; Cibik, Levent; Schreiber, Swenja; Krumrey, Michael

    2018-03-01

    Precise monitoring of the incoming photon flux is crucial for many experiments using synchrotron radiation. For photon energies above a few keV, thin semiconductor photodiodes can be operated in transmission for this purpose. Diamond is a particularly attractive material as a result of its low absorption. The responsivity of a state-of-the art diamond quadrant transmission detector has been determined, with relative uncertainties below 1% by direct calibration against an electrical substitution radiometer. From these data and the measured transmittance, the thickness of the involved layers as well as the mean electron-hole pair creation energy were determined, the latter with an unprecedented relative uncertainty of 1%. The linearity and X-ray scattering properties of the device are also described.

  6. Energy relaxation and separation of a hot electron-hole pair in organic aggregates from a time-dependent wavepacket diffusion method

    International Nuclear Information System (INIS)

    Han, Lu; Liang, WanZhen; Zhao, Yi; Zhong, Xinxin

    2014-01-01

    The time-dependent wavepacket diffusive method [X. Zhong and Y. Zhao, J. Chem. Phys. 138, 014111 (2013)] is extended to investigate the energy relaxation and separation of a hot electron-hole pair in organic aggregates with incorporation of Coulomb interaction and electron-phonon coupling. The pair initial condition generated by laser pulse is represented by a Gaussian wavepacket with a central momentum. The results reveal that the hot electron energy relaxation is very well described by two rate processes with the fast rate much larger than the slow one, consistent with experimental observations, and an efficient electron-hole separation is accomplished accompanying the fast energy relaxation. Furthermore, although the extra energy indeed helps the separation by overcoming the Coulomb interaction, the width of initial wavepacket is much sensitive to the separation efficiency and the narrower wavepacket generates the more separated charges. This behavior may be useful to understand the experimental controversy of the hot carrier effect on charge separation

  7. Study of spontaneous fission lifetimes using nuclear density functional theory

    Directory of Open Access Journals (Sweden)

    Sadhukhan Jhilam

    2013-12-01

    Full Text Available The spontaneous fission lifetimes have been studied microscopically by minimizing the collective action integral in a two-dimensional collective space of quadrupole moments (Q20, Q22 representing elongation and triaxiality. The microscopic collective potential and inertia tensor are obtained by solving the self-consistent Hartree-Fock-Bogoliubov (HFB equations with the Skyrme energy density functional and mixed pairing interaction. The mass tensor is computed within the perturbative Adiabatic Time-Dependent HFB (ATDHFB approach in the cranking approximation. The dynamic fission trajectories have been obtained by minimizing the collective action using two different numerical techniques. The values of spontaneous fission lifetimes obtained in this way are compared with the static results.

  8. Scanning Emitter Lifetime Imaging Microscopy for Spontaneous Emission Control

    DEFF Research Database (Denmark)

    Frimmer, Martin; Chen, Yuntian; Koenderink, A. Femius

    2011-01-01

    We report an experimental technique to map and exploit the local density of optical states of arbitrary planar nanophotonic structures. The method relies on positioning a spontaneous emitter attached to a scanning probe deterministically and reversibly with respect to its photonic environment while...

  9. Spontaneous emission of semiconductors in the Wigner approach

    Science.gov (United States)

    Filinov, V. S.; Hoyer, W.; Bonitz, M.; Kira, M.; Fortov, V. E.; Koch, S. W.

    2003-06-01

    This paper presents a first step towards combining two well-established methods used in semiconductor physicsmdashsemiconductor Bloch equations and the Wigner approach to quantum transport. This combination provides the possibility of including spontaneous emission, i.e., the spontaneous recombination of excited electron-hole pairs in semiconductors, into the Wigner approach, which so far has been used only for systems with fixed particle number. The theory is presented and first numerical results for a three-dimensional system are shown.

  10. Higher lifetime chance of spontaneous surface antigen loss in hepatitis B carriers with genotype C infection.

    Science.gov (United States)

    Tseng, T-C; Liu, C-J; Chen, C-L; Yang, W-T; Yang, H-C; Su, T-H; Wang, C-C; Kuo, S F-T; Liu, C-H; Chen, P-J; Chen, D-S; Kao, J-H

    2015-05-01

    Clearance of hepatitis B surface antigen (HBsAg) indicates clinical control of hepatitis B virus (HBV) infection. However, little is known about the impact of viral genomic variations on HBsAg loss. We explored the association between viral genomic factors and HBsAg loss in 2121HBeAg-negative patients. HBV pre-core stop codon (1896) and basal core promoter (BCP) (1762/1764) sequences were determined in patients with HBV DNA ≥200 IU/mL (N = 1693). The effect of HBV genotype on HBsAg loss was further validated in the whole cohort of 3445 HBsAg carriers. The cumulative lifetime (age 28-75 years) incidence of HBsAg loss was 50.4% in 2121 HBeAg-negative patients. We found that genotype C, but not pre-core stop codon or BCP mutants, was associated with HBsAg loss. Compared to genotype B patients, genotype C patients had higher lifetime chance of HBsAg loss, with hazard ratio of 1.8 (95% confidence interval: 1.4-2.4). Multivariable analysis showed that male sex, elevated ALT levels, lower serum HBV DNA and HBsAg levels, and genotype C infection were associated with higher chance of HBsAg loss independently. We then performed sensitivity analysis, which re-included HBeAg-positive, cirrhotic and treatment-experienced patients, and confirmed the robustness of our results in 3445 HBsAg carriers. Genotype C infection, compared to genotype B, is associated with a higher lifetime chance of HBsAg loss in Asian HBV carriers. © 2015 John Wiley & Sons Ltd.

  11. Associations of lifetime active and passive smoking with spontaneous abortion, stillbirth and tubal ectopic pregnancy: a cross-sectional analysis of historical data from the Women's Health Initiative.

    Science.gov (United States)

    Hyland, Andrew; Piazza, Kenneth M; Hovey, Kathleen M; Ockene, Judith K; Andrews, Christopher A; Rivard, Cheryl; Wactawski-Wende, Jean

    2015-07-01

    To examine the associations between tobacco exposure and adverse pregnancy outcomes using quantitative measures of lifetime active smoking and secondhand smoke (SHS) exposure. Historical reproductive data on 80 762 women who participated in the Women's Health Initiative Observational Study were examined with a cross-sectional analysis. We assessed self-reported lifetime active and passive tobacco smoke exposure, self-reported spontaneous abortions, stillbirths and ectopic pregnancies. When compared with never-smoking women, participants who were ever active smokers during their reproductive years had ORs (OR) of 1.16 (95% CI 1.08 to 1.26) for 1 or more spontaneous abortions, 1.44 (95% CI 1.20 to 1.73) for 1 or more stillbirths, and 1.43 (95% CI 1.10 to 1.86) for 1 or more ectopic pregnancies. Never-smoking women participants with the highest levels of lifetime SHS exposure, including childhood >10 years, adult home >20 years and adult work exposure >10 years, when compared with never-smoking women with no SHS exposure had adjusted ORs of 1.17 (95% CI 1.05 to 1.30) for spontaneous abortion, 1.55 (95% CI 1.21 to 1.97) for stillbirth, and 1.61 (95% CI 1.16 to 2.24) for ectopic pregnancy. Women who were ever-smokers during their reproductive years had significantly greater estimates of risk for spontaneous abortion, stillbirth and tubal ectopic pregnancy. Never-smoking women with the highest levels of lifetime exposure to SHS had significantly increased estimates of risk for spontaneous abortion, stillbirth and tubal ectopic pregnancy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Single-Site Active Cobalt-Based Photocatalyst with a Long Carrier Lifetime for Spontaneous Overall Water Splitting.

    Science.gov (United States)

    Liu, Wei; Cao, Linlin; Cheng, Weiren; Cao, Yuanjie; Liu, Xiaokang; Zhang, Wei; Mou, Xiaoli; Jin, Lili; Zheng, Xusheng; Che, Wei; Liu, Qinghua; Yao, Tao; Wei, Shiqiang

    2017-08-01

    An active and stable photocatalyst to directly split water is desirable for solar-energy conversion. However, it is difficult to accomplish overall water splitting without sacrificial electron donors. Herein, we demonstrate a strategy via constructing a single site to simultaneously promote charge separation and catalytic activity for robust overall water splitting. A single Co 1 -P 4 site confined on g-C 3 N 4 nanosheets was prepared by a facile phosphidation method, and identified by electron microscopy and X-ray absorption spectroscopy. This coordinatively unsaturated Co site can effectively suppress charge recombination and prolong carrier lifetime by about 20 times relative to pristine g-C 3 N 4 , and boost water molecular adsorption and activation for oxygen evolution. This single-site photocatalyst exhibits steady and high water splitting activity with H 2 evolution rate up to 410.3 μmol h -1  g -1 , and quantum efficiency as high as 2.2 % at 500 nm. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Optical excitation of electron-hole pairs in disordered one-dimensional semiconductors

    NARCIS (Netherlands)

    Mostovoy, Maxim; Antonsen, Frank; Knoester, Jasper

    2002-01-01

    We apply the optimal fluctuation method to the calculation of the optical absorption in disordered one-dimensional semiconductors below the fundamental optical gap. We find that a photon energy exists at which the shape of the optimal fluctuation undergoes a dramatic change, resulting in a different

  14. Hot carrier-enhanced interlayer electron-hole pair multiplication in 2D semiconductor heterostructure photocells

    Science.gov (United States)

    Barati, Fatemeh; Grossnickle, Max; Su, Shanshan; Lake, Roger K.; Aji, Vivek; Gabor, Nathaniel M.

    2017-12-01

    Strong electronic interactions can result in novel particle-antiparticle (electron-hole, e-h) pair generation effects, which may be exploited to enhance the photoresponse of nanoscale optoelectronic devices. Highly efficient e-h pair multiplication has been demonstrated in several important nanoscale systems, including nanocrystal quantum dots, carbon nanotubes and graphene. The small Fermi velocity and nonlocal nature of the effective dielectric screening in ultrathin layers of transition-metal dichalcogenides (TMDs) indicates that e-h interactions are very strong, so high-efficiency generation of e-h pairs from hot electrons is expected. However, such e-h pair multiplication has not been observed in 2D TMD devices. Here, we report the highly efficient multiplication of interlayer e-h pairs in 2D semiconductor heterostructure photocells. Electronic transport measurements of the interlayer I-VSD characteristics indicate that layer-indirect e-h pairs are generated by hot-electron impact excitation at temperatures near T = 300 K. By exploiting this highly efficient interlayer e-h pair multiplication process, we demonstrate near-infrared optoelectronic devices that exhibit 350% enhancement of the optoelectronic responsivity at microwatt power levels. Our findings, which demonstrate efficient carrier multiplication in TMD-based optoelectronic devices, make 2D semiconductor heterostructures viable for a new class of ultra-efficient photodetectors based on layer-indirect e-h excitations.

  15. Hot carrier-enhanced interlayer electron-hole pair multiplication in 2D semiconductor heterostructure photocells.

    Science.gov (United States)

    Barati, Fatemeh; Grossnickle, Max; Su, Shanshan; Lake, Roger K; Aji, Vivek; Gabor, Nathaniel M

    2017-12-01

    Strong electronic interactions can result in novel particle-antiparticle (electron-hole, e-h) pair generation effects, which may be exploited to enhance the photoresponse of nanoscale optoelectronic devices. Highly efficient e-h pair multiplication has been demonstrated in several important nanoscale systems, including nanocrystal quantum dots, carbon nanotubes and graphene. The small Fermi velocity and nonlocal nature of the effective dielectric screening in ultrathin layers of transition-metal dichalcogenides (TMDs) indicates that e-h interactions are very strong, so high-efficiency generation of e-h pairs from hot electrons is expected. However, such e-h pair multiplication has not been observed in 2D TMD devices. Here, we report the highly efficient multiplication of interlayer e-h pairs in 2D semiconductor heterostructure photocells. Electronic transport measurements of the interlayer I-V SD characteristics indicate that layer-indirect e-h pairs are generated by hot-electron impact excitation at temperatures near T = 300 K. By exploiting this highly efficient interlayer e-h pair multiplication process, we demonstrate near-infrared optoelectronic devices that exhibit 350% enhancement of the optoelectronic responsivity at microwatt power levels. Our findings, which demonstrate efficient carrier multiplication in TMD-based optoelectronic devices, make 2D semiconductor heterostructures viable for a new class of ultra-efficient photodetectors based on layer-indirect e-h excitations.

  16. Nuclear lifetimes

    International Nuclear Information System (INIS)

    Caraca, J.M.G.

    1976-01-01

    The importance of the results obtained in experiments of measurement of lifetimes for a detailed knowledge of nuclear structure is referred. Direct methods of measurement of nuclear lifetimes are described, namely, electronic methods, recoil-distance method, doppler shift atenuation method and blocking-method. A brief reference is made to indirect methods for measurement of life-times

  17. Boosting the Visible-Light Photoactivity of BiOCl/BiVO4/N-GQD Ternary Heterojunctions Based on Internal Z-Scheme Charge Transfer of N-GQDs: Simultaneous Band Gap Narrowing and Carrier Lifetime Prolonging.

    Science.gov (United States)

    Zhu, Mingyue; Liu, Qian; Chen, Wei; Yin, Yuanyuan; Ge, Lan; Li, Henan; Wang, Kun

    2017-11-08

    The efficient separation of photogenerated electron-hole pairs in photoactive materials is highly desired, allowing their transfer to specific sites for undergoing redox reaction in various applications. The construction of ternary heterojunctions is a practical strategy to enhance the migration of photogenerated electron that realizes the synergistic effect of multicomponents rather than the simple overlay of single component. Here, we demonstrate an available way to fabricate new BiOCl/BiVO 4 /nitrogen-doped graphene quantum dot (N-GQD) ternary heterojunctions that exhibit higher efficiency in charge separation than any binary heterojunction or pure material under visible-light irradiation. UV-vis diffuse reflectance spectroscopy demonstrated that the proposed BiOCl/BiVO 4 /N-GQD ternary heterojunctions possess the narrower band gap energy. More importantly, the ternary heterojunctions reveal the prolonged lifetime of photogenerated charges and enhanced the separation efficiency of photogenerated electron-hole pairs, which may be ascribed to sensitization based on an internal Z-scheme charge transfer at the interface of N-GQDs with oxygen functional groups. Furthermore, we examine the photoactive performance of proposed ternary heterojunctions in aqueous solution by using the photodegradation of bisphenol A as a model system and BiOCl/BiVO 4 /N-GQD ternary heterojunctions also display a dramatically enhanced photodegradation rate. The proposed charge separation and transfer process of BiOCl/BiVO 4 /N-GQD ternary heterojunctions for the enhanced photoactivity were deduced by electrochemical measurements, photoluminescence, and electron spin resonance. The results demonstrate that a Z-scheme charge process was formed between BiOCl/BiVO 4 binary heterojunctions and N-GQDs, leading to an efficient charge carrier separation and strong photocatalytic ability. Notably, this work may assist in a better understanding of the role of N-GQDs in kinds of heterojunctions

  18. Lifetime measurements

    International Nuclear Information System (INIS)

    Fossan, D.B.; Warburton, E.K.

    1974-01-01

    Lifetime measurements are discussed, concentrating on the electronic technique, the recoil distance method (RDM), and the Doppler shift attenuation method (DSAM). A brief review of several indirect timing techniques is given, and their specific advantages and applicability are considered. The relationship between lifetimes of nuclear states and the nuclear structure information obtained from them is examined. A short discussion of channeling and microwave methods of lifetime measurement is presented. (23 figures, 171 references) (U.S.)

  19. Vibrational lifetimes of hydrogen on lead films: An ab initio molecular dynamics with electronic friction (AIMDEF) study

    Energy Technology Data Exchange (ETDEWEB)

    Saalfrank, Peter [Institut für Chemie, Universität Potsdam, Karl-Liebknecht-Strasse 24-25, D-14476 Potsdam (Germany); Donostia International Physics Center (DIPC), Paseo Manuel de Lardizabal 4, 20018 Donostia-San Sebastián (Spain); Juaristi, J. I. [Donostia International Physics Center (DIPC), Paseo Manuel de Lardizabal 4, 20018 Donostia-San Sebastián (Spain); Centro de Física de Materiales CFM/MPC (CSIC-UPV/EHU), Paseo Manuel de Lardizabal 5, 20018 Donostia-San Sebastián (Spain); Departamento de Física de Materiales, Facultad de Químicas UPV/EHU, Apartado 1072, 20018 Donostia-San Sebastián (Spain); Alducin, M.; Muiño, R. Díez [Donostia International Physics Center (DIPC), Paseo Manuel de Lardizabal 4, 20018 Donostia-San Sebastián (Spain); Centro de Física de Materiales CFM/MPC (CSIC-UPV/EHU), Paseo Manuel de Lardizabal 5, 20018 Donostia-San Sebastián (Spain); Blanco-Rey, M. [Donostia International Physics Center (DIPC), Paseo Manuel de Lardizabal 4, 20018 Donostia-San Sebastián (Spain); Departamento de Física de Materiales, Facultad de Químicas UPV/EHU, Apartado 1072, 20018 Donostia-San Sebastián (Spain)

    2014-12-21

    Using density functional theory and Ab Initio Molecular Dynamics with Electronic Friction (AIMDEF), we study the adsorption and dissipative vibrational dynamics of hydrogen atoms chemisorbed on free-standing lead films of increasing thickness. Lead films are known for their oscillatory behaviour of certain properties with increasing thickness, e.g., energy and electron spillout change in discontinuous manner, due to quantum size effects [G. Materzanini, P. Saalfrank, and P. J. D. Lindan, Phys. Rev. B 63, 235405 (2001)]. Here, we demonstrate that oscillatory features arise also for hydrogen when chemisorbed on lead films. Besides stationary properties of the adsorbate, we concentrate on finite vibrational lifetimes of H-surface vibrations. As shown by AIMDEF, the damping via vibration-electron hole pair coupling dominates clearly over the vibration-phonon channel, in particular for high-frequency modes. Vibrational relaxation times are a characteristic function of layer thickness due to the oscillating behaviour of the embedding surface electronic density. Implications derived from AIMDEF for frictional many-atom dynamics, and physisorbed species will also be given.

  20. Light-induced effects on the radiative recombination rate of electron-hole pairs in a-Si:H

    Energy Technology Data Exchange (ETDEWEB)

    Ogihara, C.; Inagaki, Y. [Department of Applied Science, Yamaguchi University, Ube 755-8611 (Japan); Morigaki, K. [Department of Electrical and Digital-System Engineering, Hiroshima Institute of Technology, Miyake, Saeki-ku, Hiroshima 731-5193 (Japan)

    2011-09-15

    Temperature variation of radiative recombination rate obtained for defect photoluminescence (PL) in high-quality a-Si:H after illumination of intense pulsed light is presented and compared with results previously reported for defective a-Si:H films. We have not found significant difference between the temperature variation of the rate of radiative recombination at photo-created radiative defects and that at native radiative defects. This fact suggests the recombination processes at the photo-created defects and the native defects are similar. The temperature dependence of the radiative recombination rates in a-Si:H is predicted by a model of the recombination processes for various cases of different density of deep and strongly localised tail states. Our recent experimental results for the principal PL and defect PL coincide with the prediction of the model. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  1. Monte Carlo studies of thermalization of electron-hole pairs in spin-polarized degenerate electron gas in monolayer graphene

    Science.gov (United States)

    Borowik, Piotr; Thobel, Jean-Luc; Adamowicz, Leszek

    2018-02-01

    Monte Carlo method is applied to the study of relaxation of excited electron-hole (e-h) pairs in graphene. The presence of background of spin-polarized electrons, with high density imposing degeneracy conditions, is assumed. To such system, a number of e-h pairs with spin polarization parallel or antiparallel to the background is injected. Two stages of relaxation: thermalization and cooling are clearly distinguished when average particles energy and its standard deviation σ _E are examined. At the very beginning of thermalization phase, holes loose energy to electrons, and after this process is substantially completed, particle distributions reorganize to take a Fermi-Dirac shape. To describe the evolution of and σ _E during thermalization, we define characteristic times τ _ {th} and values at the end of thermalization E_ {th} and σ _ {th}. The dependence of these parameters on various conditions, such as temperature and background density, is presented. It is shown that among the considered parameters, only the standard deviation of electrons energy allows to distinguish between different cases of relative spin polarizations of background and excited electrons.

  2. Terahertz spectroscopy of two-dimensional electron-hole pairs: probing Mott physics of magneto-excitons

    Science.gov (United States)

    Zhang, Qi; Gao, Weilu; Watson, John; Manfra, Michael; Kono, Junichiro

    2015-03-01

    Density-dependent Coulomb interactions can drive electron-hole (e - h) pairs in semiconductors through an excitonic Mott transition from an excitonic gas into an e - h plasma. Theoretical studies suggest that these interactions can be strongly modified by an external magnetic field, including the absence of inter-exciton interactions in the high magnetic field limit in two dimensions, due to an e - h charge symmetry, which results in ultrastable magneto-excitons. Here, we present a systematic experimental study of e - h pairs in photo-excited undoped GaAs quantum wells in magnetic fields with ultrafast terahertz spectroscopy. We simultaneously monitored the dynamics of the intraexcitonic 1 s-2 p transition (which splits into 1 s-2p+ and 1 s-2p- transitions in a magnetic field) and the cyclotron resonance of unbound electrons and holes up to 10 Tesla. We found that the 1 s-2p- absorption feature is robust at high magnetic fields even under high excitation fluences, indicating magnetically enhanced stability of excitons. We will discuss the Mott physics of magneto-excitons as a function of temperature, e - h pair density, optical pump delay time, as well as magnetic field, and also compare two-dimensional excitons in GaAs quantum wells with three-dimensional excitons in bulk GaAs.

  3. Lifetime learning and lifetime education

    Directory of Open Access Journals (Sweden)

    Aljana Lepšina

    2008-12-01

    Full Text Available Effective education and lifetime learning are becoming a key to competitive, knowledge-based economy. Our country is at present, such as other European countries facing new approaches and developments in the area of education along with changes and difficulties. Third-level is known for an increased number of students, weak financial backing of universities, initial difficulties with Bologna Agreement and increased competitiveness in Europe. It is necessary to improve the education quality, encourage life-long learning and increase investments into research and development.

  4. Spontaneous pneumothorax

    Directory of Open Access Journals (Sweden)

    Davari R

    1996-07-01

    Full Text Available A case with bilateral spontaneous pneumothorax was presented. Etiology, mechanism, and treatment were discussed on the review of literature. Spontaneous Pneumothorax is a clinical entity resulting from a sudden non traumatic rupture of the lung. Biach reported in 1880 that 78% of 916 patients with spontaneous pneumothorax had tuberculosis. Kjergaard emphasized 1932 the primary importance of subpleural bleb disease. Currently the clinical spectrum of spontaneous pneumothorax seems to have entered a third era with the recognition of the interstitial lung disease and AIDS as a significant etiology. Standard treatment is including: observation, thoracocentesis, tube thoracostomy. Chemical pleurodesis, bullectomy or wedge resection of lung with pleural abrasion and occasionally pleurectomy. Little information has been reported regarding the efficacy of such treatment in spontaneous pneumothorax secondary to non bleb disease

  5. Spontaneous deregulation

    NARCIS (Netherlands)

    Edelman, Benjamin; Geradin, Damien

    Platform businesses such as Airbnb and Uber have risen to success partly by sidestepping laws and regulations that encumber their traditional competitors. Such rule flouting is what the authors call “spontaneous private deregulation,” and it’s happening in a growing number of industries. The authors

  6. Computing Battery Lifetime Distributions

    NARCIS (Netherlands)

    Cloth, L.; Haverkort, Boudewijn R.H.M.; Jongerden, M.R.

    The usage of mobile devices like cell phones, navigation systems, or laptop computers, is limited by the lifetime of the included batteries. This lifetime depends naturally on the rate at which energy is consumed, however, it also depends on the usage pattern of the battery. Continuous drawing of a

  7. Monte-Carlo simulations of geminate electron-hole pair dissociation in a molecular heterojunction: a two-step dissociation mechanism

    International Nuclear Information System (INIS)

    Offermans, Ton; Meskers, Stefan C.J.; Janssen, Rene A.J.

    2005-01-01

    The Monte-Carlo simulations are used to investigate the dissociation of a Coulomb correlated charge pair at an idealized interface between an electron accepting and an electron donating molecular material. In the simulations the materials are represented by cubic lattices of sites, with site the energies spread according to Gaussian distributions. The influence of temperature, applied external fields, and the width of the Gaussian densities of states distribution for both the electron and the hole transporting material are investigated. The results show that the dissociation of geminate charge pairs is assisted by disorder and the results can be understood in terms of a two-step model. In the first step, the slow carrier in the most disordered material jumps away from the interface. In the following, second step, the reduced Coulombic attraction allows the faster carrier in the less disordered material to escape from the interface by thermally activated hopping. When the rate for geminate recombination at the interface is very low ( -1 ) the simulations predict a high yield for carrier collection, as observed experimentally. Comparison of the simulated and experimentally observed temperature dependence of the collection efficiency indicates that at low temperature dissociation of the geminate charge pairs may be one of the factors limiting the device performance

  8. Negligible Electronic Interaction between Photoexcited Electron-Hole Pairs and Free Electrons in Phosphorus-Boron Co-Doped Silicon Nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Limpens, Rens [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Neale, Nathan R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Fujii, Minoru [Kobe University; Gregorkiewicz, Tom [University of Amsterdam

    2018-03-05

    Phosphorus (P) and boron (B) co-doped Si nanocrystals (NCs) have raised interest in the optoelectronic industry due to their electronic tunability, optimal carrier multiplication properties, and straightforward dispersibility in polar solvents. Yet a basic understanding of the interaction of photoexcited electron-hole (e-h) pairs with new physical features that are introduced by the co-doping process (free carriers, defect states, and surface chemistry) is missing. Here, we present the first study of the ultrafast carrier dynamics in SiO2-embedded P-B co-doped Si NC ensembles using induced absorption spectroscopy through a two-step approach. First, the induced absorption data show that the large fraction of the dopants residing on the NC surface slows down carrier relaxation dynamics within the first 20 ps relative to intrinsic (undoped) Si NCs, which we interpret as enhanced surface passivation. On longer time-scales (picosecond to nanosecond regime), we observe a speeding up of the carrier relaxation dynamics and ascribe it to doping-induced trap states. This argument is deduced from the second part of the study, where we investigate multiexciton interactions. From a stochastic modeling approach we show that localized carriers, which are introduced by the P or B dopants, have minor electronic interactions with the photoexcited e-h pairs. This is understood in light of the strong localization of the introduced carriers on their original P- or B-dopant atoms, due to the strong quantum confinement regime in these relatively small NCs (<6 nm).

  9. Customer Lifetime Value Measurement

    OpenAIRE

    Sharad Borle; Siddharth S. Singh; Dipak C. Jain

    2008-01-01

    The measurement of customer lifetime value is important because it is used as a metric in evaluating decisions in the context of customer relationship management. For a firm, it is important to form some expectations as to the lifetime value of each customer at the time a customer starts doing business with the firm, and at each purchase by the customer. In this paper, we use a hierarchical Bayes approach to estimate the lifetime value of each customer at each purchase occasion by jointly mod...

  10. Lifetime of organic photovoltaics

    DEFF Research Database (Denmark)

    Corazza, Michael; Krebs, Frederik C; Gevorgyan, Suren A.

    2015-01-01

    tests. Comparison of the indoor and outdoor lifetimes was performed by means of the o-diagram, which constitutes the initial steps towards establishing a method for predicting the lifetime of an organic photovoltaic device under real operational conditions based on a selection of accelerated indoor...... tests. Acceleration factors were determined using the ISOS-protocols, which enabled reproducible data acquisition between different laboratories and operators within the OPV community. A semi-automatic filtering method was employed for processing data acquired in outdoor tests. It was found...... results reveal that while the accelerated ageing studies reveal days and weeks of lifetime for the studied samples, in outdoor real operational conditions the samples demonstrate stability up to months and seasons....

  11. Lifetime of kaonium

    International Nuclear Information System (INIS)

    Krewald, S.; Lemmer, R.H.; Sassen, F.P.

    2004-01-01

    The kaon-antikaon system is studied in both the atomic and the strongly interacting sector. We discuss the influence of the structures of the f 0 (980) and the a 0 (980) mesons on the lifetime of kaonium. The strong interactions are generated by vector meson exchange within the framework of the standard SU(3) V xSU(3) A invariant effective Lagrangian. In the atomic sector, the energy levels and decay widths of kaonium are determined by an eigenvalue equation of the Kudryavtsev-Popov type, with the strong interaction effects entering through the complex scattering length for KK-bar scattering and annihilation. The presence of two scalar mesons f 0 (980) and a 0 (980) leads to a ground state energy for the kaonium atom that is shifted above the point Coulomb value by a few hundred eV. The effect on the lifetime for the kaonium decay into two pions is much more dramatic. This lifetime is reduced by two orders of magnitude from 1.2x10 -16 sec for annihilation in a pure Coulomb field down to 3.2x10 -18 sec when the strong interactions are included. The analysis of the two photon decay width of the f 0 (980) suggests a generalization of the molecular picture which reduces the lifetime of kaonium still further to 1.1x10 -18 sec

  12. Component lifetime modelling

    NARCIS (Netherlands)

    Verweij, J.F.; Verweij, J.F.; Brombacher, A.C.; Brombacher, A.C.; Lunenborg, M.M.; Lunenborg, M.M.

    1994-01-01

    There are two approaches to component lifetime modelling. The first one uses a reliability prediction method as described in the (military) handbooks with the appropriate models and parameters. The advantages are: (a) It takes into account all possible failure mechanisms. (b) It is easy to use. The

  13. Filter replacement lifetime prediction

    Science.gov (United States)

    Hamann, Hendrik F.; Klein, Levente I.; Manzer, Dennis G.; Marianno, Fernando J.

    2017-10-25

    Methods and systems for predicting a filter lifetime include building a filter effectiveness history based on contaminant sensor information associated with a filter; determining a rate of filter consumption with a processor based on the filter effectiveness history; and determining a remaining filter lifetime based on the determined rate of filter consumption. Methods and systems for increasing filter economy include measuring contaminants in an internal and an external environment; determining a cost of a corrosion rate increase if unfiltered external air intake is increased for cooling; determining a cost of increased air pressure to filter external air; and if the cost of filtering external air exceeds the cost of the corrosion rate increase, increasing an intake of unfiltered external air.

  14. Fluorescence lifetime based bioassays

    Science.gov (United States)

    Meyer-Almes, Franz-Josef

    2017-12-01

    Fluorescence lifetime (FLT) is a robust intrinsic property and material constant of fluorescent matter. Measuring this important physical indicator has evolved from a laboratory curiosity to a powerful and established technique for a variety of applications in drug discovery, medical diagnostics and basic biological research. This distinct trend was mainly driven by improved and meanwhile affordable laser and detection instrumentation on the one hand, and the development of suitable FLT probes and biological assays on the other. In this process two essential working approaches emerged. The first one is primarily focused on high throughput applications employing biochemical in vitro assays with no requirement for high spatial resolution. The second even more dynamic trend is the significant expansion of assay methods combining highly time and spatially resolved fluorescence data by fluorescence lifetime imaging. The latter approach is currently pursued to enable not only the investigation of immortal tumor cell lines, but also specific tissues or even organs in living animals. This review tries to give an actual overview about the current status of FLT based bioassays and the wide range of application opportunities in biomedical and life science areas. In addition, future trends of FLT technologies will be discussed.

  15. Spontaneous fission of neutron-rich superheavy nuclei

    International Nuclear Information System (INIS)

    Gherghiescu, R.A.

    1997-01-01

    Neutron-rich isotopes of the superheavy elements 112, 114, and 116 have been studied for neutron numbers 184, 186, and 188. The spontaneous fission life-time calculations have been performed within the WKB method. Large values have been obtained due to the proton-shell closure 114. The maximum of the fission lifetime occurs for the double-magic superheavy nucleus (114,184). (author)

  16. B meson lifetime measurement

    International Nuclear Information System (INIS)

    Piccolo, M.

    1989-01-01

    The lifetime of hadrons containing b-quark has been the subject of extensive experimental work and theoretical speculation; its importance is due to implications on some of the fundamental parameters of the Standard Model, such as the top quark mass and the mixing angles. Since the pioneer measurements of the MAC and MARK II collaborations at PEP in 1983 the progress has been impressive; but many issues still remain open and await further study. In this paper the field's present status is discussed. An overview of the theoretical motivations for this measurements in the Standard Model framework is done. Then the experimental techniques used are reviewed, emphasizing the most recent measurements. A comparison of the results obtained is done and systematic errors are discussed. In conclusion there are some remarks on the further developments foreseen in the near future

  17. Energy Savings Lifetimes and Persistence

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, Ian M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schiller, Steven R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Billingsley, Megan A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Goldman, Charles A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schwartz, Lisa C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-02-01

    This technical brief explains the concepts of energy savings lifetimes and savings persistence and discusses how program administrators use these factors to calculate savings for efficiency measures, programs and portfolios. Savings lifetime is the length of time that one or more energy efficiency measures or activities save energy, and savings persistence is the change in savings throughout the functional life of a given efficiency measure or activity. Savings lifetimes are essential for assessing the lifecycle benefits and cost effectiveness of efficiency activities and for forecasting loads in resource planning. The brief also provides estimates of savings lifetimes derived from a national collection of costs and savings for electric efficiency programs and portfolios.

  18. Positron lifetimes in deformed copper

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Doyama, Masao

    1976-01-01

    Positron lifetime measurements were performed for Cu samples with different densities of lattice defects. The lifetime spectra were successfully resolved into two components with the help of the well established analysis program. Obtained results were quite consistent with those expected from the trapping model. The positron trapping mechanism from free to trapped states and the initial condition of the model were especially checked. Deduced values obtained for tau sub(c) (lifetime of free positrons) and tau sub(t) (lifetime of trapped positrons) were 122+-5 psec and 176+-5 psec, respectively. (auth.)

  19. Spontaneous pneumothorax in weightlifters.

    Science.gov (United States)

    Marnejon, T; Sarac, S; Cropp, A J

    1995-06-01

    Spontaneous pneumothorax is infrequently caused by strenuous exertion. To our knowledge there has only been one case of spontaneous pneumothorax associated with weightlifting reported in the medical literature. We describe three consecutive cases of spontaneous pneumothorax associated with weightlifting. We postulate that spontaneous pneumothorax in these patients may be secondary to improper breathing techniques. It is important that physicians and weight trainers be aware of the association between weight lifting and spontaneous pneumothorax and assure that proper instruction is given to athletes who work with weights.

  20. Lifetime Improvement by Battery Scheduling

    NARCIS (Netherlands)

    Jongerden, M.R.; Schmitt, Jens B.; Haverkort, Boudewijn R.H.M.

    The use of mobile devices is often limited by the lifetime of their batteries. For devices that have multiple batteries or that have the option to connect an extra battery, battery scheduling, thereby exploiting the recovery properties of the batteries, can help to extend the system lifetime. Due to

  1. Lifetime improvement by battery scheduling

    NARCIS (Netherlands)

    Jongerden, M.R.; Haverkort, Boudewijn R.H.M.

    The use of mobile devices is often limited by the lifetime of its battery. For devices that have multiple batteries or that have the option to connect an extra battery, battery scheduling, thereby exploiting the recovery properties of the batteries, can help to extend the system lifetime. Due to the

  2. Lifetime costs of cerebral palsy

    DEFF Research Database (Denmark)

    Kruse, Marie; Michelsen, Susan Ishøy; Flachs, Esben Meulengracht

    2009-01-01

    This study quantified the lifetime costs of cerebral palsy (CP) in a register-based setting. It was the first study outside the US to assess the lifetime costs of CP. The lifetime costs attributable to CP were divided into three categories: health care costs, productivity costs, and social costs...... in 2000. The prevalence of CP in eastern Denmark was approximately 1.7 per 1000. Information on productivity and the use of health care was retrieved from registers. The lifetime cost of CP was about euro860 000 for men and about euro800 000 for women. The largest component was social care costs......, particularly during childhood. A sensitivity analysis found that alterations in social care costs had a small effect, whereas lowering the discount rate from 5 to 3 per cent markedly increased total lifetime costs. Discounting decreases the value of costs in the future compared with the present. The high...

  3. Electricite de France: Lifetime Project

    International Nuclear Information System (INIS)

    Combes, Jean-Pierre

    1991-01-01

    Electricite de France produces almost 80% of its electricity by means of standardized PWR nuclear power stations. Starting in 1986, therefore, a project known as the 'Lifetime Project' was developed, whose aim was initially to ensure that the lifetime defined at design stage (40 years in general) could be attained without major difficulty (follow up of the aging process). It then became apparent that it would be useful to know just how far it would be technically and economically possible to go. As a result, the project is now working towards increasing the lifetime of power stations. (author)

  4. Measurement of b hadron lifetimes and effective lifetimes at LHCb

    CERN Document Server

    Eklund, E

    2013-01-01

    This paper presents two recent measurements of b-hadron lifetimes, using 1 fb$^{-1}$ of data collected by LHCb. The effective lifetime of the $B_{s} \\to J/\\Psi K_{S}$ decay is measured and found to be $\\tau_{B_{s} \\to J/\\Psi K_{S}}^{\\rm{eff}} = 1.75 \\pm 0.12~(\\rm{stat})~0.07~(\\rm{syst})~\\rm{ps}$. The result is compatible with the Standard Model prediction and is the first measurement of this quantity. The $\\Lambda_{b}$ lifetime is measured in the $\\Lambda_{b} \\to J/\\Psi p K$ decay using the same data set. The measured quantity is the difference in reciprocal lifetimes of the $B^0$ and $\\Lambda^0_b$ hadrons and found to be $1/\\tau_{\\Lambda_{b}} - 1/\\tau_{B_{d}}= 16.4 \\pm 8.2 \\pm 4.4~\\rm{ns^{-1}}$. Using the world average of the $B^0$ lifetime, this translates into a lifetime ratio of $\\tau_{\\Lambda_{b}}/\\tau_{B_{d}} = 0.976 \\pm 0.012 \\pm 0.006$, which is the precise measurement of this quantity to date.

  5. Radiative lifetimes of neutral samarium

    International Nuclear Information System (INIS)

    Den Hartog, E A; Lawler, J E

    2013-01-01

    Radiative lifetimes of 120 odd-parity levels of neutral samarium, ranging in energy from 17 190 to 33 507 cm −1 , are measured using the technique of time-resolved laser-induced fluorescence on a slow atomic beam. This work is part of an ongoing study of radiative properties of rare earth neutral atoms, and is motivated by research needs in astrophysics and lighting technology. This set of Sm i lifetimes substantially increases the available published lifetime data, with 49 of the 120 level lifetimes measured for the first time. These data, most of which are accurate to ±5%, will be combined with branching fractions determined from Fourier transform spectroscopy to produce a large set of measured Sm i transition probabilities. (paper)

  6. Radiative lifetimes of neutral gadolinium

    International Nuclear Information System (INIS)

    Den Hartog, E A; Bilty, K A; Lawler, J E

    2011-01-01

    The current work is part of an ongoing study of radiative properties of rare earth neutral atoms motivated by research needs in several disparate fields including astrophysics, laser chemistry and lighting technology. Time-resolved laser-induced fluorescence on a slow atomic beam has been used to measure radiative lifetimes, accurate to ±5%, for 136 levels of neutral gadolinium. Of the 136 levels, 6 are odd parity ranging in energy from 32 929 to 36 654 cm -1 , and the remaining 130 are even parity ranging from 17 750 to 34 175 cm -1 . This set of Gd i lifetimes represents a significant extension to the available published data, with 93 of the 136 level lifetimes measured for the first time. These lifetimes will provide the absolute normalization for a large set of measured Gd i transition probabilities.

  7. Deconvolution of Positrons' Lifetime spectra

    International Nuclear Information System (INIS)

    Calderin Hidalgo, L.; Ortega Villafuerte, Y.

    1996-01-01

    In this paper, we explain the iterative method previously develop for the deconvolution of Doppler broadening spectra using the mathematical optimization theory. Also, we start the adaptation and application of this method to the deconvolution of positrons' lifetime annihilation spectra

  8. Spontaneous uterine rupture

    African Journals Online (AJOL)

    ABSTRACT. Rupture of a gravid uterus is a surgical emergency. Predisposing factors include a scarred uterus. Spontaneous rupture of an unscarred uterus during pregnancy is a rare occurrence. We hereby present the case of a spontaneous complete uterine rupture at a gestational age of 34 weeks in a 35 year old patient ...

  9. Spontaneous intracranial hypotension.

    LENUS (Irish Health Repository)

    Fullam, L

    2012-01-31

    INTRODUCTION: Spontaneous\\/primary intracranial hypotension is characterised by orthostatic headache and is associated with characteristic magnetic resonance imaging findings. CASE REPORT: We present a case report of a patient with typical symptoms and classical radiological images. DISCUSSION: Spontaneous intracranial hypotension is an under-recognised cause of headache and can be diagnosed by history of typical orthostatic headache and findings on MRI brain.

  10. Optical Measurement Techniques of Recombination Lifetime Based on the Free Carriers Absorption Effect

    Directory of Open Access Journals (Sweden)

    Martina De Laurentis

    2014-01-01

    Full Text Available We review successful measurement techniques for the evaluation of the recombination properties in semiconductor materials based on the optically induced free carrier absorption. All the methodologies presented share the common feature of exploiting a laser beam to excite electron-hole pairs within the volume of the sample under investigation, while the probing methods can vary according to the different methodology analyzed. As recombination properties are of paramount importance in determining the properties of semiconductor devices (i.e, bipolar transistor gain, power devices switching features, and solar cells efficiency, their knowledge allows for better understanding of experimental results and robust TCAD simulator calibration. Being contactless and applicable without any particular preparation of the sample under investigation, they have been considered attractive to monitor these parameters inline or just after production of many different semiconductor devices.

  11. Occupational risk and lifetime exposure

    International Nuclear Information System (INIS)

    Lapp, R.E.

    1991-01-01

    Any lowering of annual radiation limits for occupational exposure should be based on industry experience with lifetime doses and not on a worst case career exposure of 47 years. Two decades of experience show a lifetime accumulation of less than 1.5 rem for workers with measurable exposure. This is 5% of the normal lifetime exposure of Americans to natural and medical radiation. Any epidemiology of the US nuclear power workforce's two decade long exposure would have to focus on excess leukemia. Application of the Hiroshima and Nagasaki cancer mortality shows that too few leukemias would be expressed to permit a feasible epidemiology. Ionizing radiation appears to be a mild carcinogen as compared to physical and chemical agents presented in the occupational environment. A realistic factor in determining any change in occupational exposure limits for ionizing radiation should take into account the past performance of the licensee and potential health effects applicable to the workplace. Specifically, the lifetime exposure data for workers at nuclear power plants and naval shipyards should be considered. The nuclear industry and the US Navy have detailed data on the annual exposure of workers with a combined collective exposure approaching 1 million worker-rem. The lifetime dose for naval personnel and shipyard workers averages 1.1 rem J 1990. Shipyard workers have an annual dose of 0.28 rem per work-year and a mean exposure time of 4.4 years. The data apply to workers with measurable dose

  12. Radiative lifetimes of neutral neodymium

    International Nuclear Information System (INIS)

    Den Hartog, E A; Fittante, A J; Lawler, J E

    2011-01-01

    This work is part of an on-going study of radiative properties of rare earth neutral atoms. This work is motivated by research needs in several disparate fields including astrophysics and lighting technology. Radiative lifetimes of 100 levels of neutral neodymium are measured using the technique of time-resolved laser-induced fluorescence on a slow atomic beam. Of the 100 levels, 3 are even parity ranging in energy from 25 746 to 26 835 cm -1 , and the remaining 97 are odd parity ranging from 17 787 to 27 786 cm -1 . This set of Nd i lifetimes represents a significant extension to the available published data, with 51 of the 100 level lifetimes measured for the first time. These data, which are accurate to ±5%, provide the absolute normalization for a large set of measured Nd i transition probabilities.

  13. Proton radioactivity lifetimes using Skyrme interactions

    International Nuclear Information System (INIS)

    Routray, T.R.; Tripathy, S.K.; Mishra, Abhishek; Basu, D.N.

    2011-01-01

    The phenomena of proton radioactivity is recent and has been possible with the advent of the radioactive ion beams facilities. The neutron deficient nuclei lying above the proton drip line has positive Q values for protons and are spontaneous proton emitters. This limits the possibilities of the creation of ever more exotic nuclei in the proton rich side of the β stability valley. Limited number of works have been done in calculating the half lives of proton emitting nuclei using different models. But calculation of lifetimes of the proton emitting nuclei using Skyrme interaction has not yet been reported. More than 110 Skyrme sets are available, constructed for different purposes, all having the common feature of giving finite nuclei ground state properties and saturation conditions in nuclear matter. Skyrme sets constructed in the late 90's, particularly the construction of SLy sets and others Skyrme sets developed thereafter, have additional care in constraining the parameters for applications to nuclear matter under extreme conditions. Stone et al. have analyzed the Skyrme sets on the basis of available constraints and have sorted out finally 27 Skyrmes sets which can be admitted for calculation of isospin rich dense nuclear matter. The objective of the work is to examine the predictions of the Skyrme sets on the half lives of the proton emitters

  14. Lifetime of heavy flavour particles

    International Nuclear Information System (INIS)

    Lueth, V.

    1985-10-01

    Recent measurements of the lifetime of the tau leptons and charm and beauty hadrons are reviewed and their significance for the couplings of the charged weak current, flavour mixing, and models relating quarks to hadron decay are discussed. 70 refs., 17 figs., 5 tabs

  15. Lifetime value in business process

    Directory of Open Access Journals (Sweden)

    Martin Souček

    2011-01-01

    Full Text Available The paper focuses on lifetime value assessment and its implementation and application in business processes. The lifetime value is closely connected to customer relationship management. The paper presents results of three consecutive researches devoted to issues of customer relationship management. The first two from 2008 and 2010 were conducted as quantitative ones; the one from 2009 had qualitative nature. The respondents were representatives of particular companies. The means for data collection was provided by ReLa system. We will focus on individual attributes of lifetime value of a customer, and relate them to approaches of authors mentioned in introduction. Based on the qualitative research data, the paper focuses on individual customer lifetime value parameters. These parameters include: the cost to the customer relationship acquisition and maintenance, profit generated from a particular customer, customer awareness value, the level of preparedness to adopt new products, the value of references and customer loyalty level. For each of these parameters, the paper provides specific recommendations. Moreover, it is possible to learn about the nature of these parameter assessments in the Czech environment.

  16. Controlling the spontaneous emission of a superconducting transmon qubit.

    Science.gov (United States)

    Houck, A A; Schreier, J A; Johnson, B R; Chow, J M; Koch, Jens; Gambetta, J M; Schuster, D I; Frunzio, L; Devoret, M H; Girvin, S M; Schoelkopf, R J

    2008-08-22

    We present a detailed characterization of coherence in seven transmon qubits in a circuit QED architecture. We find that spontaneous emission rates are strongly influenced by far off-resonant modes of the cavity and can be understood within a semiclassical circuit model. A careful analysis of the spontaneous qubit decay into a microwave transmission-line cavity can accurately predict the qubit lifetimes over 2 orders of magnitude in time and more than an octave in frequency. Coherence times T1 and T_{2};{*} of more than a microsecond are reproducibly demonstrated.

  17. Spontaneous Atraumatic Mediastinal Hemorrhage

    Directory of Open Access Journals (Sweden)

    Morkos Iskander BSc, BMBS, MRCS, PGCertMedEd

    2013-04-01

    Full Text Available Spontaneous atraumatic mediastinal hematomas are rare. We present a case of a previously fit and well middle-aged lady who presented with acute breathlessness and an increasing neck swelling and spontaneous neck bruising. On plain chest radiograph, widening of the mediastinum was noted. The bruising was later confirmed to be secondary to mediastinal hematoma. This life-threatening diagnostic conundrum was managed conservatively with a multidisciplinary team approach involving upper gastrointestinal and thoracic surgeons, gastroenterologists, radiologists, intensivists, and hematologists along with a variety of diagnostic modalities. A review of literature is also presented to help surgeons manage such challenging and complicated cases.

  18. Lifetime of a black hole

    International Nuclear Information System (INIS)

    Carlitz, R.D.; Willey, R.S.

    1987-01-01

    We study the constraints placed by quantum mechanics upon the lifetime of a black hole. In the context of a moving-mirror analog model for the Hawking radiation process, we conclude that the period of Hawking radiation must be followed by a much longer period during which the remnant mass (of order m/sub P/) may be radiated away. We are able to place a lower bound on the time required for this radiation process, which translates into a lower bound for the lifetime of the black hole. Particles which are emitted during the decay of the remnant, like the particles which comprise the Hawking flux, may be uncorrelated with each other. But each particle emitted from the decaying remnant is correlated with one particle emitted as Hawking radiation. The state which results after the remnant has evaporated is one which locally appears to be thermal, but which on a much larger scale is marked by extensive correlations

  19. Luminosity lifetime in the Tevatron

    International Nuclear Information System (INIS)

    Jackson, G.; Finley, D.; Johnson, R.P.; Kerns, Q.; McCarthy, J.; Siemann, R.; Zhang, P.

    1988-01-01

    Since the inauguration of colliding proton-antiproton operations in 1987, the Tevatron has exhibited luminosity lifetimes shorter than expected. During a typical colliding beam storage period, called a store, luminosity is calculated periodically by measuring the charge and emittances of each bunch. The growth of the transverse bunch emittances is the dominant cause of luminosity deterioration. Throughout, this period, the position spectrum of the bunches exhibited betatron signals larger than expected from Schottky noise. A model assuming externally driven betatron oscillations explains both the betatron signals and the emittance growth. A program is underway to improve the Tevatron luminosity lifetime. The abort kickers have been identified as sources of emittance growth, and some quadrupole power supplies are further candidates. Because the horizontal dispersion through the RF cavities is nonzero, RF phase noise has been investigated. Noise in the main dipole regulation circuit has also been studied. 13 refs., 4 figs

  20. Fluorescence lifetime of emitters with broad homogeneous linewidths modified in opal photonic crystals

    DEFF Research Database (Denmark)

    Nikolaev, Ivan S.; Lodahl, Peter; Vos, Willem L.

    2008-01-01

    We have investigated the dynamics of spontaneous emission from dye molecules embedded in opal photonic crystals. Fluorescence lifetimes of Rhodamine 6G (R6G) dye were measured as a function of both optical frequency and crystal lattice parameter of the polystyrene opals. Due to the broad...... homogeneous line width of the dye, the observed fluorescence lifetime varies only slightly with the frequency within the dye emission spectrum. The lifetime however does change as a function of the crystal lattice parameter. Our observations agree with theoretical calculations of the local density of optical...... states (LDOS) in the three-dimensional photonic crystals. The experiments and theory taken together reveal that the emission lifetime is modified over frequency ranges that are broader than the homogeneous emission line width of R6G dye....

  1. Spontaneous Appendicocutaneous Fistula I

    African Journals Online (AJOL)

    M T0k0de* MB, BS and. Dr 0. A. AWOj0bi+ FMCS (Nig). ABSTRACT. Ruptured appendicitis is not a common cause of spontaneous enterocutaneous fistula. A case of ruptured retrocaecal appendicitis presenting as an enterocutaneous fistula in a Nigerian woman is presented. The literature on this disorder is also reviewed.

  2. [Spontaneous bacterial peritonitis].

    Science.gov (United States)

    Strauss, Edna; Caly, Wanda Regina

    2003-01-01

    Spontaneous bacterial peritonitis occurs in 30% of patients with ascites due to cirrhosis leading to high morbidity and mortality rates. The pathogenesis of spontaneous bacterial peritonitis is related to altered host defenses observed in end-stage liver disease, overgrowth of microorganisms, and bacterial translocation from the intestinal lumen to mesenteric lymph nodes. Clinical manifestations vary from severe to slight or absent, demanding analysis of the ascitic fluid. The diagnosis is confirmed by a number of neutrophils over 250/mm3 associated or not to bacterial growth in culture of an ascites sample. Enterobacteriae prevail and Escherichia coli has been the most frequent bacterium reported. Mortality rates decreased markedly in the last two decades due to early diagnosis and prompt antibiotic treatment. Third generation intravenous cephalosporins are effective in 70% to 95% of the cases. Recurrence of spontaneous bacterial peritonitis is common and can be prevented by the continuous use of oral norfloxacin. The development of bacterial resistance demands the search for new options in the prophylaxis of spontaneous bacterial peritonitis; probiotics are a promising new approach, but deserve further evaluation. Short-term antibiotic prophylaxis is recommended for patients with cirrhosis and ascites shortly after an acute episode of gastrointestinal bleeding.

  3. Spontaneous Grammar Explanations.

    Science.gov (United States)

    Tjoo, Hong Sing; Lewis, Marilyn

    1998-01-01

    Describes one New Zealand university language teacher's reflection on her own grammar explanations to university-level students of Bahasa Indonesian. Examines form-focused instruction through the teacher's spontaneous answers to students' questions about the form of the language they are studying. The teacher's experiences show that it takes time…

  4. EDITORIAL SPONTANEOUS BACTERIAL PERITONITIS ...

    African Journals Online (AJOL)

    hi-tech

    Spontaneous bacterial peritonitis (SBP) frequent]y occurs in patients with liver cirrhosis and ascites. It is defined as an infection of previously sterile ascitic fluid without any demonstrable intrabdominal source of infection. It is now internationally agreed that a polymorphonuclear (PMN) cell count in the ascitic fluid of over 250 ...

  5. Spontaneous dimensional reduction?

    Science.gov (United States)

    Carlip, Steven

    2012-10-01

    Over the past few years, evidence has begun to accumulate suggesting that spacetime may undergo a "spontaneous dimensional reduction" to two dimensions near the Planck scale. I review some of this evidence, and discuss the (still very speculative) proposal that the underlying mechanism may be related to short-distance focusing of light rays by quantum fluctuations.

  6. Personality, IQ, and Lifetime Earnings

    DEFF Research Database (Denmark)

    Gensowski, Miriam

    2018-01-01

    This paper estimates the effects of personality traits and IQ on lifetime earnings of the men and women of the Terman study, a high-IQ U.S. sample. Age-by-age earnings profiles allow a study of when personality traits affect earnings most, and for whom the effects are strongest. I document...... a concave life-cycle pattern in the payoffs to personality traits, with the largest effects between the ages of 40 and 60. An interaction of traits with education reveals that personality matters most for highly educated men. The largest effects are found for Conscientiousness, Extraversion...

  7. Personality, IQ, and Lifetime Earnings

    OpenAIRE

    Gensowski, Miriam

    2014-01-01

    This paper estimates the eects of personality traits and IQ on lifetime earnings of the men and women of the Terman study, a high-IQ U.S. sample. Age-by-age earnings proles allow a study of when personality traits aect earnings most, and for whom the eects are strongest. I document a concave life-cycle pattern in the payos to personality traits, with the largest eects between the ages of 40 and 60. An interaction of traits with education reveals that personality matters most for highly educat...

  8. Lifetime of superheated steam components

    International Nuclear Information System (INIS)

    Stoklossa, K.H.; Oude-Hengel, H.H.; Kraechter, H.J.

    1974-01-01

    The current evaluation schemes in use for judging the lifetime expectations of superheated steam components are compared with each other. The influence of pressure and temperature fluctuations, the differences in the strength of the wall, and the spread band of constant-strainrates are critically investigated. The distribution of these contributory effects are demonstrated in the hight of numerous measuring results. As an important supplement to these evaluation schemes a newly developed technique is introduced which is designed to calculate failure probabilities. (orig./RW) [de

  9. Spontaneous healing of spontaneous coronary artery dissection.

    Science.gov (United States)

    Almafragi, Amar; Convens, Carl; Heuvel, Paul Van Den

    2010-01-01

    Spontaneous coronary artery dissection (SCAD) is a rare cause of acute coronary syndrome and sudden cardiac death. It should be suspected in every healthy young woman without cardiac risk factors, especially during the peripartum or postpartum periods. It is important to check for a history of drug abuse, collagen vascular disease or blunt trauma of the chest. Coronary angiography is essential for diagnosis and early management. We wonder whether thrombolysis might aggravate coronary dissection. All types of treatment (medical therapy, percutaneous intervention or surgery) improve the prognosis without affecting survival times if used appropriately according to the clinical stability and the angiographic features of the involved coronary arteries. Prompt recognition and targeted treatment improve outcomes. We report a case of SCAD in a young female free of traditional cardiovascular risk factors, who presented six hours after thrombolysis for ST elevation myocardial infarction. Coronary angiography showed a dissection of the left anterior descending and immediate branch. She had successful coronary artery bypass grafting, with complete healing of left anterior descending dissection.

  10. Spontaneous spinal epidural abscess.

    LENUS (Irish Health Repository)

    Ellanti, P

    2011-10-01

    Spinal epidural abscess is an uncommon entity, the frequency of which is increasing. They occur spontaneously or as a complication of intervention. The classical triad of fever, back pain and neurological symptoms are not always present. High index of suspicion is key to diagnosis. Any delay in diagnosis and treatment can have significant neurological consequences. We present the case of a previously well man with a one month history of back pain resulting from an epidural abscess.

  11. Lifetimes and heavy quark expansion

    Science.gov (United States)

    Lenz, Alexander

    2015-04-01

    Kolya Uraltsev was one of the inventors of the Heavy Quark Expansion (HQE), that describes inclusive weak decays of hadrons containing heavy quarks and in particular lifetimes. Besides giving a pedagogic introduction to the subject, we review the development and the current status of the HQE, which just recently passed several non-trivial experimental tests with an unprecedented precision. In view of many new experimental results for lifetimes of heavy hadrons, we also update several theory predictions: τ (B+)/τ (Bd) = 1.04+0.05-0.01 ± 0.02 ± 0.01, τ(Bs)/τ(Bd) = 1.001 ±0.002, τ(Λb)/τ(Bd) = 0.935 ±0.054 and \\bar {τ } (Ξ b0)/\\bar {τ } (Ξ b+) = 0.95 ± 0.06. The theoretical precision is currently strongly limited by the unknown size of the non-perturbative matrix elements of four-quark operators, which could be determined with lattice simulations.

  12. Uncertainties in the proton lifetime

    International Nuclear Information System (INIS)

    Ellis, J.; Nanopoulos, D.V.; Rudaz, S.; Gaillard, M.K.

    1980-04-01

    We discuss the masses of the leptoquark bosons m(x) and the proton lifetime in Grand Unified Theories based principally on SU(5). It is emphasized that estimates of m(x) based on the QCD coupling and the fine structure constant are probably more reliable than those using the experimental value of sin 2 theta(w). Uncertainties in the QCD Λ parameter and the correct value of α are discussed. We estimate higher order effects on the evolution of coupling constants in a momentum space renormalization scheme. It is shown that increasing the number of generations of fermions beyond the minimal three increases m(X) by almost a factor of 2 per generation. Additional uncertainties exist for each generation of technifermions that may exist. We discuss and discount the possibility that proton decay could be 'Cabibbo-rotated' away, and a speculation that Lorentz invariance may be violated in proton decay at a detectable level. We estimate that in the absence of any substantial new physics beyond that in the minimal SU(5) model the proton lifetimes is 8 x 10 30+-2 years

  13. Personality, IQ, and Lifetime Earnings

    DEFF Research Database (Denmark)

    Gensowski, Miriam

    2014-01-01

    , as identified in a factor model, significantly affect earnings, but not for young workers. The effects are furthermore heterogeneous by educational attainment. For women, personality traits do not affect family earnings in the same way as own earnings. Personality and IQ also influence earnings indirectly......Talented individuals are seen as drivers of long-term growth, but how do they realize their full potential? In this paper, I show that lifetime earnings of high-IQ men and women are substantially influenced by their personality traits, in addition to intelligence and education. Personality traits...... on detailed background information. This paper complements the literature on investments in education and personality traits by showing that they also have potentially high returns at the high end of the ability distribution....

  14. Spontaneous Thigh Compartment Syndrome

    Directory of Open Access Journals (Sweden)

    Khan, Sameer K

    2011-02-01

    Full Text Available A young man presented with a painful and swollen thigh, without any history of trauma, illness, coagulopathic medication or recent exertional exercise. Preliminary imaging delineated a haematoma in the anterior thigh, without any fractures or muscle trauma. Emergent fasciotomies were performed. No pathology could be identified intra-operatively, or on follow-up imaging. A review of thigh compartment syndromes described in literature is presented in a table. Emergency physicians and traumatologists should be cognisant of spontaneous atraumatic presentations of thigh compartment syndrome, to ensure prompt referral and definitive management of this limb-threatening condition. [West J Emerg Med. 2011;12(1:134-138].

  15. Lifetime of Organic Photovoltaics: Status and Predictions

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Madsen, Morten Vesterager; Roth, Bérenger

    2016-01-01

    The results of a meta-analysis conducted on organic photovoltaics (OPV) lifetime data reported in the literature is presented through the compilation of an extensive OPV lifetime database based on a large number of articles, followed by analysis of the large body of data. We fully reveal the prog......The results of a meta-analysis conducted on organic photovoltaics (OPV) lifetime data reported in the literature is presented through the compilation of an extensive OPV lifetime database based on a large number of articles, followed by analysis of the large body of data. We fully reveal...... the progress of reported OPV lifetimes. Furthermore, a generic lifetime marker has been defi ned, which helps with gauging and comparing the performance of different architectures and materials from the perspective of device stability. Based on the analysis, conclusions are drawn on the bottlenecks...

  16. Maximizing System Lifetime by Battery Scheduling

    OpenAIRE

    Jongerden, M.R.; Haverkort, Boudewijn R.H.M.; Bohnenkamp, H.C.; Katoen, Joost P.

    2009-01-01

    The use of mobile devices is limited by the battery lifetime. Some devices have the option to connect an extra battery, or to use smart battery-packs with multiple cells to extend the lifetime. In these cases, scheduling the batteries over the load to exploit recovery properties usually extends the system lifetime. Straightforward scheduling schemes, like round robin or choosing the best battery available, already provide a big improvement compared to a sequential discharge of the batteries. ...

  17. The Susquehanna plant lifetime excellence program

    International Nuclear Information System (INIS)

    McNamara, R.W.

    1988-01-01

    This paper discusses how the Susquehanna plant lifetime excellence program (SPLEX) blends many of the objectives of a new managing for excellence program with plant life extension objectives to achieve excellence in the lifetime operation and availability of the two-unit Susquehanna steam electric station. Investments in lifetime excellence improvements will provide near-term, as well as plant life extension, benefits. A high-quality lifetime experience record, together with extensive, periodic technical assessments and cost-benefit analyses, will provide conclusive justification for future extensions of the unit operating licenses

  18. Spontaneous Tumor Lysis Syndrome

    Directory of Open Access Journals (Sweden)

    Alicia C. Weeks MD

    2015-08-01

    Full Text Available Tumor lysis syndrome (TLS is a known complication of malignancy and its treatment. The incidence varies on malignancy type, but is most common with hematologic neoplasms during cytotoxic treatment. Spontaneous TLS is thought to be rare. This case study is of a 62-year-old female admitted with multisystem organ failure, with subsequent diagnosis of aggressive B cell lymphoma. On admission, laboratory abnormalities included renal failure, elevated uric acid (20.7 mg/dL, and 3+ amorphous urates on urinalysis. Oliguric renal failure persisted despite aggressive hydration and diuretic use, requiring initiation of hemodialysis prior to chemotherapy. Antihyperuricemic therapy and hemodialysis were used to resolve hyperuricemia. However, due to multisystem organ dysfunction syndrome with extremely poor prognosis, the patient ultimately expired in the setting of a terminal ventilator wean. Although our patient did not meet current TLS criteria, she required hemodialysis due to uric acid nephropathy, a complication of TLS. This poses the clinical question of whether adequate diagnostic criteria exist for spontaneous TLS and if the lack of currently accepted guidelines has resulted in the underestimation of its incidence. Allopurinol and rasburicase are commonly used for prevention and treatment of TLS. Although both drugs decrease uric acid levels, allopurinol mechanistically prevents formation of the substrate rasburicase acts to solubilize. These drugs were administered together in our patient, although no established guidelines recommend combined use. This raises the clinical question of whether combined therapy is truly beneficial or, conversely, detrimental to patient outcomes.

  19. Spontaneous Intracranial Hypotension

    International Nuclear Information System (INIS)

    Joash, Dr.

    2015-01-01

    Epidemiology is not only rare but an important cause of new daily persistent headaches among young & middle age individuals. The Etiology & Pathogenesis is generally caused by spinal CSF leak. Precise cause remains largely unknown, underlying structural weakness of spinal meninges is suspected. There are several MR Signs of Intracranial Hypotension that include:- diffuse pachymeningeal (dural) enhancement; bilateral subdural, effusion/hematomas; Downward displacement of brain; enlargement of pituitary gland; Engorgement of dural venous sinuses; prominence of spinal epidural venous plexus and Venous sinus thrombosis & isolated cortical vein thrombosis. The sum of volumes of intracranial blood, CSF & cerebral tissue must remain constant in an intact cranium. Treatment in Many cases can be resolved spontaneously or by use Conservative approach that include bed rest, oral hydration, caffeine intake and use of abdominal binder. Imaging Modalities for Detection of CSF leakage include CT myelography, Radioisotope cisternography, MR myelography, MR imaging and Intrathecal Gd-enhanced MR

  20. Spontaneous wave packet reduction

    International Nuclear Information System (INIS)

    Ghirardi, G.C.

    1994-06-01

    There are taken into account the main conceptual difficulties met by standard quantum mechanics in dealing with physical processes involving macroscopic system. It is stressed how J.A.Wheeler's remarks and lucid analysis have been relevant to pinpoint and to bring to its extreme consequences the puzzling aspects of quantum phenomena. It is shown how the recently proposed models of spontaneous dynamical reduction represent a consistent way to overcome the conceptual difficulties of the standard theory. Obviously, many nontrivial problems remain open, the first and more relevant one being that of generalizing the model theories considered to the relativistic case. This is the challenge of the dynamical reduction program. 43 refs, 2 figs

  1. Mean fluorescence lifetime and its error

    Energy Technology Data Exchange (ETDEWEB)

    Fiserova, Eva [Department of Mathematical Analysis and Applications of Mathematics, Faculty of Science, Palacky University in Olomouc, tr. 17. listopadu 12, CZE-77146 Olomouc (Czech Republic); Kubala, Martin, E-mail: mkubala@prfnw.upol.cz [Department of Biophysics, Faculty of Science, Palacky University in Olomouc, tr. 17. listopadu 12, CZE-77146 Olomouc (Czech Republic)

    2012-08-15

    Mean excited-state lifetime is one of the fundamental fluorescence characteristics and enters as an important parameter into numerous calculations characterizing molecular interactions, such as e.g. FRET or fluorescence quenching. Our experiments demonstrated that the intensity-weighted mean fluorescence lifetime is very robust characteristic, in contrast to the amplitude-weighted one, which value is dependent on the data quality and particularly on the used fitting model. For the first time, we also report the procedure for the error estimation for both the intensity- and amplitude-weighted mean fluorescence lifetimes. Furthermore, we present a method for estimation of the mean fluorescence lifetime directly from the fluorescence-decay curve recorded by TCSPC (Time-Correlated Single-Photon Counting) method. For its simplicity and low computational demands, it could be a useful tool in the high-throughput applications, such as FACS, FLIM-FRET or HPLC detectors. - Highlights: Black-Right-Pointing-Pointer Intensity-weighted mean fluorescence lifetime is very robust characteristic. Black-Right-Pointing-Pointer The amplitude-weighted mean lifetime depends on the selection of fitting model. Black-Right-Pointing-Pointer Rigorous procedure for estimation of confidence intervals for mean lifetime. Black-Right-Pointing-Pointer The mean lifetime can be estimated directly from the TCSPC histogram.

  2. Computing lifetimes for battery-powered devices

    NARCIS (Netherlands)

    Jongerden, M.R.; Haverkort, Boudewijn R.H.M.

    The battery lifetime of mobile devices depends on the usage pattern of the battery, next to the discharge rate and the battery capacity. Therefore, it is important to include the usage pattern in battery lifetime computations. We do this by combining a stochastic workload, modeled as a

  3. A measurement of the D0 lifetime

    International Nuclear Information System (INIS)

    Althoff, M.; Braunschweig, W.; Gerhards, R.; Kirschfink, F.J.; Martyn, H.U.; Rosskamp, R.; Wallraff, W.; Hilger, E.; Kracht, T.; Krasemann, H.L.; Krueger, J.; Lohrmann, E.; Poelz, G.; Poesnecker, K.U.; Bowler, M.G.; Bull, P.; Cashmore, R.J.; Dauncey, P.; Devenish, R.; Heath, G.; Mellor, D.J.; Ratoff, P.; Yelton, J.M.; Baranko, G.; Caldwell, A.; Cherney, M.; DeMille, D.; Izen, J.M.; Messersmith, J.; Ritz, S.; Strom, D.; Takashima, M.; Wicklund, E.; Wu Saulan; Zobernig, G.

    1986-01-01

    We have determined the D 0 lifetime from reconstructed vertices of D 0 mesons produced in e + e - annihilations at an average center of mass energy of 42.2 GeV. From fifteen events the D 0 lifetime was determined to be (4.3+-1.7+-0.8)x10 -13 s. (orig.)

  4. Fluorescence lifetime imaging using light emitting diodes

    International Nuclear Information System (INIS)

    Kennedy, Gordon T; Munro, Ian; Poher, Vincent; French, Paul M W; Neil, Mark A A; Elson, Daniel S; Hares, Jonathan D

    2008-01-01

    We demonstrate flexible use of low cost, high-power light emitting diodes as illumination sources for fluorescence lifetime imaging (FLIM). Both time-domain and frequency-domain techniques have been implemented at wavelengths spanning the range 450-640 nm. Additionally, we demonstrate optically sectioned fluorescence lifetime imaging by combining structured illumination with frequency-domain FLIM

  5. Baselines for Lifetime of Organic Solar Cells

    DEFF Research Database (Denmark)

    Gevorgyan, Suren; Espinosa Martinez, Nieves; Ciammaruchi, Laura

    2016-01-01

    The process of accurately gauging lifetime improvements in organic photovoltaics (OPVs) or other similar emerging technologies, such as perovskites solar cells is still a major challenge. The presented work is part of a larger effort of developing a worldwide database of lifetimes that can help...

  6. Maximizing System Lifetime by Battery Scheduling

    NARCIS (Netherlands)

    Jongerden, M.R.; Haverkort, Boudewijn R.H.M.; Bohnenkamp, H.C.; Katoen, Joost P.

    2009-01-01

    The use of mobile devices is limited by the battery lifetime. Some devices have the option to connect an extra battery, or to use smart battery-packs with multiple cells to extend the lifetime. In these cases, scheduling the batteries over the load to exploit recovery properties usually extends the

  7. Spontaneous compactification to homogeneous spaces

    International Nuclear Information System (INIS)

    Mourao, J.M.

    1988-01-01

    The spontaneous compactification of extra dimensions to compact homogeneous spaces is studied. The methods developed within the framework of coset space dimensional reduction scheme and the most general form of invariant metrics are used to find solutions of spontaneous compactification equations

  8. Screening for spontaneous preterm birth

    NARCIS (Netherlands)

    van Os, M.A.; van Dam, A.J.E.M.

    2015-01-01

    Preterm birth is the most important cause of perinatal morbidity and mortality worldwide. In this thesis studies on spontaneous preterm birth are presented. The main objective was to investigate the predictive capacity of mid-trimester cervical length measurement for spontaneous preterm birth in a

  9. Spontaneous Pneumomediastinum: Hamman Syndrome

    Directory of Open Access Journals (Sweden)

    Tushank Chadha, BS

    2018-04-01

    significant fat stranding. The image also showed an intraluminal stent traversing the gastric antrum and gastric pylorus with no indication of obstruction. Circumferential mural thickening of the gastric antrum and body were consistent with the patient’s history of gastric adenocarcinoma. The shotty perigastric lymph nodes with associated fat stranding, along the greater curvature of the distal gastric body suggested local regional nodal metastases and possible peritoneal carcinomatosis. The thoracic CT scans showed extensive pneumomediastinum that tracked into the soft tissues of the neck, which given the history of vomiting also raised concern for esophageal perforation. There was still no evidence of mediastinal abscess or fat stranding. Additionally, a left subclavian vein port catheter, which terminates with tip at the cavoatrial junction of the superior vena cava can also be seen on the image. Discussion: Spontaneous Pneumomediastinum, also known as Hamman syndrome, is defined by the uncommon incidence of free air in the mediastinum due to the bursting of alveoli, as a result of extended spells of shouting, coughing, or vomiting.1,2 The condition is diagnosed when a clear cause (aerodigestive rupture, barotrauma, infection secondary to gas-forming organisms3 for pneumomediastinum cannot be clearly identified on diagnostic studies. Macklin and Macklin were the first to note the pathogenesis of the syndrome and explained that the common denominator to spontaneous pneumomediastinum was that increased alveolar pressure leads to alveolar rupture.3 Common clinical findings for spontaneous pneumomediastinum include: chest pain, dyspnea, cough, and emesis.4 The condition is not always readily recognized on initial presentation in part for its rare incidence, estimated to be approximately 1 in every 44,500 ED patients3and also because of the non-specific presenting symptoms. For this patient, there was no clear singular cause, and therefore she received care for spontaneous

  10. Nuclear Power Plant Lifetime Management Study (I)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Yull; Jeong, Ill Seok; Jang, Chang Heui; Song, Taek Ho; Song, Woo Young [Korea Electric Power Research Institute, Taejon (Korea, Republic of); Jin, Tae Eun [Korea Power Engineering Company Consulting and Architecture Engineers, (Korea, Republic of); Kim, Woo Chul [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-12-31

    As the operation-year of nuclear power plant increases and finding sites for new nuclear power plant becomes harder, a comprehensive and systematic nuclear plant lifetime management(PLIM) program including life extension has to be established for stable and safe supply of electricity. A feasibility study was conducted to systematically evaluate technical, economic and regulatory aspect of plant lifetime managements and plant life extension for Kori-1 nuclear power plant. For technical evaluation of nuclear power plant, 13 major components were selected for lifetime evaluation by screening system. structure, and components(SSCs) of the plant. It was found that except reactor pressure vessel, which needs detailed integrity analysis, and low pressure turbine, which is scheduled to be replaced, 11 out of 13 major components have sufficient service life, for more than 40 years. Because domestic rules and regulations related to license renewal has not yet been written, review on the regulatory aspect of life extensions was conducted using US NRC rules and regulations. A cooperative effort with nuclear regulatory body is needed for early completion of license renewal rules and regulations. For economic evaluation of plant lifetime extension, a computer program was developed and used. It was found that 10 to 20 year of extension operation of Kori-1 nuclear power plant was proved. Based on the results, next phase of plant lifetime management program for detailed lifetime evaluation and presenting detailed implementation schedule for plant refurbishment for lifetime extension should be followed. (author). 74 refs., figs.

  11. Statistical Models and Methods for Lifetime Data

    CERN Document Server

    Lawless, Jerald F

    2011-01-01

    Praise for the First Edition"An indispensable addition to any serious collection on lifetime data analysis and . . . a valuable contribution to the statistical literature. Highly recommended . . ."-Choice"This is an important book, which will appeal to statisticians working on survival analysis problems."-Biometrics"A thorough, unified treatment of statistical models and methods used in the analysis of lifetime data . . . this is a highly competent and agreeable statistical textbook."-Statistics in MedicineThe statistical analysis of lifetime or response time data is a key tool in engineering,

  12. Orbital Lifetime Analysis for Nanosatellites at LEO

    Science.gov (United States)

    Cubillos Jara, D. J.; Soliz Torrico, J. A.; Ramírez Suárez, O. L.

    2018-01-01

    Nanosatellites at low earth orbit (LEO) have multiple applications such as monitoring environmental conditions, measuring ionosphere properties, improving communications, among others. These applications have lead to increase the effort of estimating orbital lifetimes for nanosatellites because they define the maximum operational time of a mission. In this report, we estimate orbital lifetimes of nanosatellites at LEO taking into account the gravitational interaction, Earth deformations, atmospheric drag and satellite initial conditions. Highest, mean and lowest lifetimes for nanosatellites of 1U, 2U and 3U in an equatorial orbit are computed by assuming a density profile according to literature and hypothetical uncertainties.

  13. Lifetime of B hadrons from CDF

    International Nuclear Information System (INIS)

    Miao, Ting.

    1996-08-01

    A review of the lifetimes of B hadrons measured by the CDF collaboration at Fermilab is presented. The data corresponds to 110 pb -1 of p anti p collisions at √s = 1.8 TeV. The inclusive B hadron lifetime is measured using a high statistics sample of B → J/ΨΧ decays. Species specific lifetimes of the B + , B 0 , B 0 s , and Λ 0 b are determined using both fully reconstructed decays and partially reconstructed decays consisting of a lepton associated with a charm hadron

  14. Models for Battery Reliability and Lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Smith, K.; Wood, E.; Santhanagopalan, S.; Kim, G. H.; Neubauer, J.; Pesaran, A.

    2014-03-01

    Models describing battery degradation physics are needed to more accurately understand how battery usage and next-generation battery designs can be optimized for performance and lifetime. Such lifetime models may also reduce the cost of battery aging experiments and shorten the time required to validate battery lifetime. Models for chemical degradation and mechanical stress are reviewed. Experimental analysis of aging data from a commercial iron-phosphate lithium-ion (Li-ion) cell elucidates the relative importance of several mechanical stress-induced degradation mechanisms.

  15. Spontaneous breaking of supersymmetry

    Energy Technology Data Exchange (ETDEWEB)

    Zumino, B.

    1981-12-01

    There has been recently a revival of interest in supersymmetric gauge theories, stimulated by the hope that supersymmetry might help in clarifying some of the questions which remain unanswered in the so called Grand Unified Theories and in particular the gauge hierarchy problem. In a Grand Unified Theory one has two widely different mass scales: the unification mass M approx. = 10/sup 15/GeV at which the unification group (e.g. SU(5)) breaks down to SU(3) x SU(2) x U(1) and the mass ..mu.. approx. = 100 GeV at which SU(2) x U(1) is broken down to the U(1) of electromagnetism. There is at present no theoretical understanding of the extreme smallness of the ratio ..mu../M of these two numbers. This is the gauge hierarchy problem. This lecture attempts to review the various mechanisms for spontaneous supersymmetry breaking in gauge theories. Most of the discussions are concerned with the tree approximation, but what is presently known about radiative correction is also reviewed.

  16. Spontaneous intracranial hypotension

    International Nuclear Information System (INIS)

    Haritanti, A.; Karacostas, D.; Drevelengas, A.; Kanellopoulos, V.; Paraskevopoulou, E.; Lefkopoulos, A.; Economou, I.; Dimitriadis, A.S.

    2009-01-01

    Spontaneous intracranial hypotension (SIH) is an uncommon but increasingly recognized syndrome. Orthostatic headache with typical findings on magnetic resonance imaging (MRI) are the key to diagnosis. Delayed diagnosis of this condition may subject patients to unnecessary procedures and prolong morbidity. We describe six patients with SIH and outline the important clinical and neuroimaging findings. They were all relatively young, 20-54 years old, with clearly orthostatic headache, minimal neurological signs (only abducent nerve paresis in two) and diffuse pachymeningeal gadolinium enhancement on brain MRI, while two of them presented subdural hygromas. Spinal MRI was helpful in detecting a cervical cerebrospinal fluid leak in three patients and dilatation of the vertebral venous plexus with extradural fluid collection in another. Conservative management resulted in rapid resolution of symptoms in five patients (10 days-3 weeks) and in one who developed cerebral venous sinus thrombosis, the condition resolved in 2 months. However, this rapid clinical improvement was not accompanied by an analogous regression of the brain MR findings that persisted on a longer follow-up. Along with recent literature data, our patients further point out that SIH, to be correctly diagnosed, necessitates increased alertness by the attending physician, in the evaluation of headaches

  17. Spontaneous lateral temporal encephalocele.

    Science.gov (United States)

    Tuncbilek, Gokhan; Calis, Mert; Akalan, Nejat

    2013-01-01

    A spontaneous encephalocele is one that develops either because of embryological maldevelopment or from a poorly understood postnatal process that permits brain herniation to occur. We here report a rare case of lateral temporal encephalocele extending to the infratemporal fossa under the zygomatic arch. At birth, the infant was noted to have a large cystic mass in the right side of the face. After being operated on initially in another center in the newborn period, the patient was referred to our clinic with a diagnosis of temporal encephalocele. He was 6 months old at the time of admission. Computerized tomography scan and magnetic resonance imaging studies revealed a 8 × 9 cm fluid-filled, multiloculated cystic mass at the right infratemporal fossa. No intracranial pathology or connection is seen. The patient was operated on to reduce the distortion effect of the growing mass. The histopathological examination of the sac revealed well-differentiated mature glial tissue stained with glial fibrillary acid protein. This rare clinical presentation of encephaloceles should be taken into consideration during the evaluation of the lateral facial masses in the infancy period, and possible intracranial connection should be ruled out before surgery to avoid complications.

  18. Bilateral spontaneous carotid artery dissection.

    Science.gov (United States)

    Townend, Bradley Scott; Traves, Laura; Crimmins, Denis

    2005-06-01

    Bilateral internal carotid artery dissections have been reported, but spontaneous bilateral dissections are rare. Internal carotid artery dissection can present with a spectrum of symptoms ranging from headache to completed stroke. Two cases of spontaneous bilateral carotid artery dissection are presented, one with headache and minimal symptoms and the other with a stroke syndrome. No cause could be found in either case, making the dissections completely spontaneous. Bilateral internal carotid artery dissection (ICAD) should be considered in young patients with unexplained head and neck pain with or without focal neurological symptoms and signs. The increasing availability of imaging would sustain the higher index of suspicion.

  19. Lifetime measurements of hadrons containing heavy quarks

    International Nuclear Information System (INIS)

    Forden, G.E.

    1985-01-01

    Recent lifetime measurements of heavy particles at PETRA and PEP are reviewed. A comparison of the methods used is given. The world averages for the lifetimes of the D 0 and D +- mesons are found to be (tau/dub D/ 0 ) - 3.97 +/- 0.3 x 10 -13 sec and (tau/dub D +-/) = 8.6 +/- 0.7 x 10 -13 sec. This difference in lifetimes is discussed in light of recent information about exclusive decays. The world average for the lifetime of bottom hadrons is determined to be (tau/sub b/) = 11.0 +/- 1.5 x 10 -13 sec and new estimates for the b quark mixing elements, absolute value V/sub bu/ and absolute value V/sub bc/, are given

  20. Lifetime measurements of excited Co I levels

    CERN Document Server

    Klotz, W D; Gobel, L H

    1977-01-01

    In the region of 3500 AA the lifetimes of eight excited Cobalt I levels have been measured by means of the zero field level crossing method. The measured lifetimes belong to the odd configurations 3d/sup 7/4s4p and 3d/sup 8/4p and are of the accuracy of about 5%. The hyperfine structure of levels with I not=J has to be taken into account in evaluating lifetimes from level crossing data, because the nuclear spin of the natural isotope /sup 59/Co is I=7/2. Therefore the influence of the line profile of the exciting resonance lines on the lifetimes has been investigated. The results are compared with those of other authors. Furthermore absolute oscillator strengths were calculated with known branching ratios and a new absolute scale has been established. (23 refs).

  1. Improved b lifetime measurement from MAC

    International Nuclear Information System (INIS)

    Ford, W.T.

    1984-03-01

    Two recent publications, from the MAC and Mark II collaborations, have reported the somewhat surprising result that the lifetime of particles made up of b quarks is in the 1 to 2 picosecond range, or somewhat longer than the lifetimes of charm particles. Although the charm decays are favored transitions while those of b particles depend upon off-diagonal elements of the weak flavor mixing matrix, the smallness of the b decay rates in face of the large available phase space indicates that the off-diagonal elements are indeed very small. The possibility for complete determination of the mixing matrix was brought significantly nearer by the availability of the lifetime information; what is needed now is to reduce the uncertainty of the measurements, which was about 33% for both experiments. We describe here an extension of the b lifetime study with the MAC detector, incorporating some new data and improvements in the analysis. 12 references

  2. Remote UV Fluorescence Lifetime Spectrometer, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this project is to develop, demonstrate, and deliver to NASA an innovative, portable, and power efficient Remote UV Fluorescence Lifetime Spectrometer...

  3. Λc photoproduction and lifetime measurement

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Bagliesi, G.; Batignani, G.; Bertolucci, E.; Bettoni, D.; Bizetti, A.; Bosisio, L.; Bottigli, U.; Bradaschia, C.; Dell'Orso, M.; Fidecaro, F.; Foa, L.; Focardi, E.; Giannetti, P.; Giorgi, M.A.; Marrocchesi, P.S.; Menzione, A.; Raso, G.; Ristori, L.; Scribano, A.; Stefanini, A.; Tenchini, R.; Tonelli, G.; Triggiani, G.; Beck, G.A.; Bologna, G.; D'Ettorre Piazzoli, B.; Picchi, P.; Budinich, M.; Liello, F.; Milotti, E.; Rolandi, L.; Carter, J.; Green, M.G.; Landon, M.P.J.; March, P.V.; Sacks, L.; Sanjari, A.H.; Strong, J.A.; Ciocci, M.A.; Enorini, M.; Fabbri, F.L.; Laurelli, P.; Mannocchi, G.; Simonelli, L.; Spillantini, P.; Zallo, A.

    1987-01-01

    A measurement of the lifetime of the Λ c baryon photoproduced coherently of a germanium-silicon target is presented. A signal of Λ c → ΔΚ * → pKππ 0 has been observed and the two different decay diagrams for this process are compared. A sample of 9 Λ c decays give a lifetime of 1.1(+0.8-0.4)10 13 s. (orig.)

  4. Measurement of the Omega0(c) lifetime

    International Nuclear Information System (INIS)

    Iori, M.

    2007-01-01

    The authors report a precise measurement of the (Omega) c 0 lifetime. The data were taken by the SELEX (E781) experiment using 600 GeV/c Σ - , π - and p beams. The measurement has been made using 83 ± 19 reconstructed (Omega) c 0 in the (Omega) - π - π + π + and (Omega) - π + decay modes. The lifetime of the (Omega) c 0 is measured to be 65 ± 13(stat) ± 9(sys) fs

  5. The total lifetime costs of smoking

    DEFF Research Database (Denmark)

    Rasmussen, S.R.; Prescott, E.; Sørensen, T.I.A.

    2004-01-01

    Net costs of smoking in a lifetime perspective and, hence, the economic interests in antismoking policies have been questioned. It has been proposed that the health-related costs of smoking are balanced by smaller expenditure due to shorter life expectancy.......Net costs of smoking in a lifetime perspective and, hence, the economic interests in antismoking policies have been questioned. It has been proposed that the health-related costs of smoking are balanced by smaller expenditure due to shorter life expectancy....

  6. The measurement of subnanosecond nuclear lifetimes

    International Nuclear Information System (INIS)

    White, D.C.S.

    1974-01-01

    This research dealt with the measurement of subnanosecond nuclear lifetimes using the pulsed beam delayed-coincidence technique. Measurements were performed on isotopes in the f7/2 shell and specifically the isotopes of titanium and vanadium. Experimental investigations were also pursued in 59 Ni and 65 Zn. Several new lifetimes were determined and confirmation was obtained for some previous values which were measured with different techniques. More information was also obtained on certain levels where previous results are in disagreement. (author)

  7. Measurements of heavy quark and lepton lifetimes

    International Nuclear Information System (INIS)

    Jaros, J.A.

    1985-02-01

    The PEP/PETRA energy range has proved to be well-suited for the study of the lifetimes of hadrons containing the b and c quarks and the tau lepton for several reasons. First, these states comprise a large fraction of the total interaction rate in e + e - annihilation and can be cleanly identified. Second, the storage rings have operated at high luminosity and so produced these exotic states copiously. And finally, thanks to the interplay of the Fermi coupling strength, the quark and lepton masses, and the beam energy, the expected decay lengths are in the 1/2 mm range and so are comparatively easy to measure. This pleasant coincidence of cleanly identified and abundant signal with potentially large effects has made possible the first measurements of two fundamental weak couplings, tau → nu/sub tau/W and b → cW. These measurements have provided a sharp test of the standard model and allowed, for the first time, the full determination of the magnitudes of the quark mixing matrix. This paper reviews the lifetime studies made at PEP during the past year. It begins with a brief review of the three detectors, DELCO, MAC and MARK II, which have reported lifetime measurements. Next it discusses two new measurements of the tau lifetime, and briefly reviews a measurement of the D 0 lifetime. Finally, it turns to measurements of the B lifetime, which are discussed in some detail. 18 references, 14 figures, 1 table

  8. Spontaneous intraorbital hematoma: case report

    Directory of Open Access Journals (Sweden)

    Vinodan Paramanathan

    2010-12-01

    Full Text Available Vinodan Paramanathan, Ardalan ZolnourianQueen's Hospital NHS Foundation Trust, Burton on Trent, Staffordshire DE13 0RB, UKAbstract: Spontaneous intraorbital hematoma is an uncommon clinical entity seen in ophthalmology practice. It is poorly represented in the literature. Current evidence attributes it to orbital trauma, neoplasm, vascular malformations, acute sinusitis, and systemic abnormalities. A 65-year-old female presented with spontaneous intraorbital hematoma manifesting as severe ocular pains, eyelid edema, proptosis, and diplopia, without a history of trauma. Computer tomography demonstrated a fairly well defined extraconal lesion with opacification of the paranasal sinuses. The principal differential based on all findings was that of a spreading sinus infection and an extraconal tumor. An unprecedented finding of a spontaneous orbital hematoma was discovered when the patient was taken to theater. We discuss the rarity of this condition and its management.Keywords: hemorrhage, ophthalmology, spontaneous, intra-orbital, hematoma

  9. Spontaneous ischaemic stroke in dogs

    DEFF Research Database (Denmark)

    Gredal, Hanne Birgit; Skerritt, G. C.; Gideon, P.

    2013-01-01

    Translation of experimental stroke research into the clinical setting is often unsuccessful. Novel approaches are therefore desirable. As humans, pet dogs suffer from spontaneous ischaemic stroke and may hence offer new ways of studying genuine stroke injury mechanisms.......Translation of experimental stroke research into the clinical setting is often unsuccessful. Novel approaches are therefore desirable. As humans, pet dogs suffer from spontaneous ischaemic stroke and may hence offer new ways of studying genuine stroke injury mechanisms....

  10. Spontaneity and international marketing performance

    OpenAIRE

    Souchon, Anne L.; Hughes, Paul; Farrell, Andrew M.; Nemkova, Ekaterina; Oliveira, Joao S.

    2016-01-01

    The file attached to this record is the author's final peer reviewed version. The Publisher's final version can be found by following the DOI link. Purpose – The purpose of this paper is to ascertain how today’s international marketers can perform better on the global scene by harnessing spontaneity. Design/methodology/approach – The authors draw on contingency theory to develop a model of the spontaneity – international marketing performance relationship, and identify three potential m...

  11. LIFETIME PRODUCTION OF SLOVENIAN LOCAL GOAT BREEDS

    Directory of Open Access Journals (Sweden)

    Metka Žan Lotrič

    2015-09-01

    Full Text Available The objective of the study was to analyze lifetime production data for two Slovenian locally adapted dairy breeds: Slovenian Saanen goat (334 and Slovenian Alpine goat (1105 and for the dairy type of Dreznica goat (141 which is the only Slovenian autochthonous goat breed. Dataset included records from 54 farms. Data for does born after 2002 have been obtained from the database of the National selection program for small ruminants, collected by the ICAR standards. The contribution of farm to phenotypic variance was estimated. Data was analyzed by MIXED procedure in SAS/STAT. The results showed significant effect of breed, farm and year of culling on all traits studied, except the effect of breed on completed lactations in lifetime and number of liveborn kids. The lifetime milk yield was higher in Slovenian Alpine goat compared to Slovenian Saanen goat by 413.26±172.52 kg. The difference in lifetime protein yield between Slovenian Alpine goat and Slovenian Saanen goat amounted to 11.76±5.21 kg. Dreznica goat did not differ in lifetime milk production and protein yield compared to both intensive goat breeds. Dreznica goat yielded about 25.50±5.21 kg more fat in lifetime compared to Slovenian Saanen goat. However, compared to Slovenian Alpine goat the difference was not significant. Comparison of Slovenian Saanen goat and Slovenian Alpine goat revealed higher lifetime fat yield of Slovenian Alpine goat by 13.28±5.21 kg. The results suggested reasonably good performance and adaptation of the autochthonous breed Dreznica goat in local agro climatic conditions.

  12. Lifetime economic burden of prostate cancer

    Directory of Open Access Journals (Sweden)

    Stokes Michael E

    2011-12-01

    Full Text Available Abstract Background Prostate cancer (PCa is the most common cancer affecting men in the United States. The initial treatment and subsequent monitoring of PCa patients places a large burden on U.S. health care systems. The objectives of this study were to estimate the total and disease-related per-patient lifetime costs using a phase-based model of cancer care for PCa patients enrolled in Medicare. Methods A model was developed to estimate life-time costs for patients diagnosed with PCa. Patients ≥ 65 years old and diagnosed with PCa between calendar years 1991-2002 were selected from the SEER database. Using SEER, we estimated survival times for PCa patients from diagnosis until death. The period of time patients contributed to treatment phases was determined using an algorithm designed to model the natural history of PCa. Costs were obtained from the US SEER-Medicare database and estimated during specific phases of care. Cost estimates were then combined with survival data to yield total and PCa-related life-time costs. Results Overall, the model estimated life-time costs of $110,520 (95% CI 110,324-110,739 per patient. PCa-related costs made up approximately 31% of total costs ($34,432. Conclusions Prostate cancer places a significant burden on U.S. health-care systems with average life-time PCa-related costs in excess of $30,000.

  13. A case of spontaneous ventriculocisternostomy

    International Nuclear Information System (INIS)

    Yamane, Kanji; Yoshimoto, Hisanori; Harada, Kiyoshi; Uozumi, Tohru; Kuwabara, Satoshi.

    1983-01-01

    The authors experienced a case of spontaneous ventriculocisternostomy diagnosed by CT scan with metrizamide and Conray. Patient was 23-year-old male who had been in good health until one month before admission, when he began to have headache and tinnitus. He noticed bilateral visual acuity was decreased about one week before admission and vomiting appeared two days before admission. He was admitted to our hospital because of bilateral papilledema and remarkable hydrocephalus diagnosed by CT scan. On admission, no abnormal neurological signs except for bilateral papilledema were noted. Immediately, right ventricular drainage was performed. Pressure of the ventricle was over 300mmH 2 O and CSF was clear. PVG and PEG disclosed an another cavity behind the third ventricle, which was communicated with the third ventricle, and occlusion of aqueduct of Sylvius. Metrizamide CT scan and Conray CT scan showed a communication between this cavity and quadrigeminal and supracerebellar cisterns. On these neuroradiological findings, the diagnosis of obstructive hydrocephalus due to benign aqueduct stenosis accompanied with spontaneous ventriculocisternostomy was obtained. Spontaneous ventriculocisternostomy was noticed to produce arrest of hydrocephalus, but with our case, spontaneous regression of such symptoms did not appeared. By surgical ventriculocisternostomy (method by Torkildsen, Dandy, or Scarff), arrest of hydrocephalus was seen in about 50 to 70 per cent, which was the same results as those of spontaneous ventriculocisternostomy. It is concluded that VP shunt or VA shunt is thought to be better treatment of obstructive hydrocephalus than the various kinds of surgical ventriculocisternostomy. (J.P.N.)

  14. Optical antenna enhanced spontaneous emission.

    Science.gov (United States)

    Eggleston, Michael S; Messer, Kevin; Zhang, Liming; Yablonovitch, Eli; Wu, Ming C

    2015-02-10

    Atoms and molecules are too small to act as efficient antennas for their own emission wavelengths. By providing an external optical antenna, the balance can be shifted; spontaneous emission could become faster than stimulated emission, which is handicapped by practically achievable pump intensities. In our experiments, InGaAsP nanorods emitting at ∼ 200 THz optical frequency show a spontaneous emission intensity enhancement of 35 × corresponding to a spontaneous emission rate speedup ∼ 115 ×, for antenna gap spacing, d = 40 nm. Classical antenna theory predicts ∼ 2,500 × spontaneous emission speedup at d ∼ 10 nm, proportional to 1/d(2). Unfortunately, at d antenna efficiency drops below 50%, owing to optical spreading resistance, exacerbated by the anomalous skin effect (electron surface collisions). Quantum dipole oscillations in the emitter excited state produce an optical ac equivalent circuit current, I(o) = qω|x(o)|/d, feeding the antenna-enhanced spontaneous emission, where q|x(o)| is the dipole matrix element. Despite the quantum-mechanical origin of the drive current, antenna theory makes no reference to the Purcell effect nor to local density of states models. Moreover, plasmonic effects are minor at 200 THz, producing only a small shift of antenna resonance frequency.

  15. The lifetime cost of a magnetic refrigerator

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Bahl, Christian R.H.; Nielsen, Kaspar Kirstein

    2016-01-01

    The total cost of a 25 W average load magnetic refrigerator using commercial grade Gd is calculated using a numerical model. The price of magnetocaloric material, magnet material and cost of operation are considered, and all influence the total cost. The lowest combined total cost with a device...... lifetime of 15 years is found to be in the range $150-$400 depending on the price of the magnetocaloric and magnet material. The cost of the magnet is largest, followed closely by the cost of operation, while the cost of the magnetocaloric material is almost negligible. For the lowest cost device......, the optimal magnetic field is about 1.4 T, the particle size is 0.23 mm, the length of the regenerator is 40-50 mm and the utilization is about 0.2, for all device lifetimes and material and magnet prices, while the operating frequency vary as function of device lifetime. The considered performance...

  16. Measurement of the $\\tau$ lepton lifetime

    CERN Document Server

    Buskulic, Damir; De Bonis, I; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Odier, P; Pietrzyk, B; Ariztizabal, F; Chmeissani, M; Crespo, J M; Efthymiopoulos, I; Fernández, E; Fernández-Bosman, M; Gaitan, V; Garrido, L; Martínez, M; Orteu, S; Pacheco, A; Padilla, C; Palla, Fabrizio; Pascual, A; Perlas, J A; Sánchez, F; Teubert, F; Colaleo, A; Creanza, D; De Palma, M; Farilla, A; Gelao, G; Girone, M; Iaselli, Giuseppe; Maggi, G; Maggi, M; Marinelli, N; Natali, S; Nuzzo, S; Ranieri, A; Raso, G; Romano, F; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Bonvicini, G; Cattaneo, M; Comas, P; Coyle, P; Drevermann, H; Engelhardt, A; Forty, Roger W; Frank, M; Hagelberg, R; Harvey, J; Jacobsen, R; Janot, P; Jost, B; Kneringer, E; Knobloch, J; Lehraus, Ivan; Markou, C; Martin, E B; Mato, P; Minten, Adolf G; Miquel, R; Oest, T; Palazzi, P; Pater, J R; Pusztaszeri, J F; Ranjard, F; Rensing, P E; Rolandi, Luigi; Schlatter, W D; Schmelling, M; Schneider, O; Tejessy, W; Tomalin, I R; Venturi, A; Wachsmuth, H W; Wiedenmann, W; Wildish, T; Witzeling, W; Wotschack, J; Ajaltouni, Ziad J; Bardadin-Otwinowska, Maria; Barrès, A; Boyer, C; Falvard, A; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rossignol, J M; Saadi, F; Fearnley, Tom; Hansen, J B; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Kyriakis, A; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Zachariadou, K; Blondel, A; Bonneaud, G R; Brient, J C; Bourdon, P; Passalacqua, L; Rougé, A; Rumpf, M; Tanaka, R; Valassi, Andrea; Verderi, M; Videau, H L; Candlin, D J; Parsons, M I; Focardi, E; Parrini, G; Corden, M; Delfino, M C; Georgiopoulos, C H; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Pepé-Altarelli, M; Dorris, S J; Halley, A W; ten Have, I; Knowles, I G; Lynch, J G; Morton, W T; O'Shea, V; Raine, C; Reeves, P; Scarr, J M; Smith, K; Smith, M G; Thompson, A S; Thomson, F; Thorn, S; Turnbull, R M; Becker, U; Braun, O; Geweniger, C; Graefe, G; Hanke, P; Hepp, V; Kluge, E E; Putzer, A; Rensch, B; Schmidt, M; Sommer, J; Stenzel, H; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Colling, D J; Dornan, Peter J; Konstantinidis, N P; Moneta, L; Moutoussi, A; Nash, J; San Martin, G; Sedgbeer, J K; Stacey, A M; Dissertori, G; Girtler, P; Kuhn, D; Rudolph, G; Bowdery, C K; Brodbeck, T J; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Sloan, Terence; Whelan, E P; Williams, M I; Galla, A; Greene, A M; Kleinknecht, K; Quast, G; Raab, J; Renk, B; Sander, H G; Wanke, R; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Bencheikh, A M; Benchouk, C; Bonissent, A; Bujosa, G; Calvet, D; Carr, J; Diaconu, C A; Etienne, F; Thulasidas, M; Nicod, D; Payre, P; Rousseau, D; Talby, M; Abt, I; Assmann, R W; Bauer, C; Blum, Walter; Brown, D; Dietl, H; Dydak, Friedrich; Ganis, G; Gotzhein, C; Jakobs, K; Kroha, H; Lütjens, G; Lutz, Gerhard; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Saint-Denis, R; Wolf, G; Alemany, R; Boucrot, J; Callot, O; Cordier, A; Courault, F; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacquet, M; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Musolino, G; Nikolic, I A; Park, H J; Park, I C; Schune, M H; Simion, S; Veillet, J J; Videau, I; Abbaneo, D; Azzurri, P; Bagliesi, G; Batignani, G; Bettarini, S; Bozzi, C; Calderini, G; Carpinelli, M; Ciocci, M A; Ciulli, V; Dell'Orso, R; Fantechi, R; Ferrante, I; Fidecaro, F; Foà, L; Forti, F; Giassi, A; Giorgi, M A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Rizzo, G; Sanguinetti, G; Sciabà, A; Spagnolo, P; Steinberger, Jack; Tenchini, Roberto; Tonelli, G; Triggiani, G; Vannini, C; Verdini, P G; Walsh, J; Betteridge, A P; Blair, G A; Bryant, L M; Cerutti, F; Gao, Y; Green, M G; Johnson, D L; Medcalf, T; Mir, L M; Perrodo, P; Strong, J A; Bertin, V; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Edwards, M; Maley, P; Norton, P R; Thompson, J C; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Marx, B; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Trabelsi, A; Vallage, B; Johnson, R P; Kim, H Y; Litke, A M; McNeil, M A; Taylor, G; Beddall, A; Booth, C N; Boswell, R; Cartwright, S L; Combley, F; Dawson, I; Köksal, A; Letho, M; Newton, W M; Rankin, C; Thompson, L F; Böhrer, A; Brandt, S; Cowan, G D; Feigl, E; Grupen, Claus; Lutters, G; Minguet-Rodríguez, J A; Rivera, F; Saraiva, P; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Ragusa, F; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Bellantoni, L; Elmer, P; Feng, Z; Ferguson, D P S; Gao, Y S; González, S; Grahl, J; Harton, J L; Hayes, O J; Hu, H; McNamara, P A; Nachtman, J M; Orejudos, W; Pan, Y B; Saadi, Y; Schmitt, M; Scott, I J; Sharma, V; Turk, J; Walsh, A M; Wu Sau Lan; Wu, X; Yamartino, J M; Zheng, M; Zobernig, G

    1996-01-01

    The mean lifetime of the \\tau lepton is measured in a sample of 25700 \\tau pairs collected in 1992 with the ALEPH detector at LEP. A new analysis of the 1-1 topology events is introduced. In this analysis, the dependence of the impact parameter sum distribution on the daughter track momenta is taken into account, yielding improved precision compared to other impact parameter sum methods. Three other analyses of the one- and three-prong \\tau decays are updated with increased statistics. The measured lifetime is 293.5 \\pm 3.1 \\pm 1.7 \\fs. Including previous (1989--1991) ALEPH measurements, the combined \\tau lifetime is 293.7 \\pm 2.7 \\pm 1.6 \\fs.

  17. Lifetime of the metastable 23S1 state in stored Li+ ions

    International Nuclear Information System (INIS)

    Knight, R.D.

    1979-04-01

    A laser-induced fluorescence technique combined with the observation of spontaneous magnetic dipole photons from the highly metastable 2 3 S 1 state of Li + was used to measure the radiative lifetime of this state. The ions are created by electron impact on a lithium atomic beam and are subsequently stored for periods of many seconds in an RF-quadrupole ion trap. A tunable dye laser excites the 2 3 S--2 3 P, transition at 5485A, and the intercombination electric dipole transition 2 3 P 1 --1 1 S 0 at 202A is observed. This process depletes the metastable population in a time tau/sub d/ 3 S 1 / and provides a measure of the total number of metastables. Comparison with the rate of 210A spontaneously emitted photons yields a measured value for the 2 3 S 1 radiative lifetime of tau/sub rad/ = 58.6 +- 12.9 sec, where the quoted error represents 95% confidence levels. The theoretical lifetime is tau/sub theory/ = 49.0 sec. The measured value includes data taken with both 6 Li + and 7 Li + isotopes and was corrected for the slightly different detector efficiencies at 202A and 210A. A careful study of nonradiative quenching of the metastable state was necessary to understand observed differences between tau/sub rad/ and tau/sub 3 S 1 /, the total metastable lifetime. Spatial density profiles of the ions within the trap, useful for determining the ion temperature, were obtained by scanning the laser beam horizontally across the ion trap while storing 2 3 P 1 -- 1 S 0 photon counts as a function of the laser beam's position. Agreement with a simple equilibrium model, including space charge effects, is satisfactory. A study of the optical pumping process is necessary to understand the laser-ion interaction, and observational and theoretical data are presented. 47 references

  18. An approach for longer lifetime MCFCs

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masaru; Tatsumi, Masahiko; Hayano, Takuro [MCFC Research Association, Tokyo (Japan)] [and others

    1996-12-31

    For entering into commercialization of MCFC power plants in the beginning of the 21st century, we will devote to research for increasing lifetime as long as 40,000 hours with cell performance decay rate of 0.25 %/1000hrs as the target in FY 1999. This paper will discuss on our approach for longer lifetime MCFCs through electrolyte-loss management and NiO precipitation management as well as micro-structural control of electrodes and matrix plates. Cell voltage decay rate will be estimated by simulation through series of experiments on accelerated conditions.

  19. Quantum system lifetimes and measurement perturbations

    International Nuclear Information System (INIS)

    Najakov, E.

    1977-05-01

    The recently proposed description of quantum system decay in terms of repeated measurement perturbations is modified. The possibility of retarded reductions to a unique quantum state, due to ineffective localization of the decay products at initial time measurements, is simply taken into account. The exponential decay law is verified again. A modified equation giving the observed lifetime in terms of unperturbed quantum decay law, measurement frequency and reduction law is derived. It predicts deviations of the observed lifetime from the umperturbed one, together with a dependence on experimental procedures. The influence of different model unperturbed decay laws and reduction laws on this effect is studied

  20. Permeability log using new lifetime measurements

    International Nuclear Information System (INIS)

    Dowling, D.J.; Boyd, J.F.; Fuchs, J.A.

    1975-01-01

    Comparative measurements of thermal neutron decay time are obtained for a formation after irradiation with a pulsed neutron source. Chloride ions in formation fluids are concentrated by the electrosmosis effect using charged poles on a well logging sonde. The formation is irradiated with fast neutrons and a first comparative measure of the thermal neutron decay time or neutron lifetime is taken. The chloride ions are then dispersed by acoustic pumping with a magnetostrictive transducer. The formation is then again irradiated with fast neutrons and a comparative measure of neutron lifetime is taken. The comparison is a function of the variation in chloride concentration between the two measurements which is related to formation permeability

  1. Extension of the nuclear power plant lifetime

    International Nuclear Information System (INIS)

    Keramsi, Alain

    2011-01-01

    After a presentation of the French nuclear context (history of the reactor fleet, choice of reactor type, PWR operation principle, competitiveness, environmental performance), this Power Point presentation addresses the context and challenges of the operation lifetime (average fleet age in different countries, examples of extensions, case of the United States, what is at stake with lifetime extension, decennial visits, EDF strategy), discusses the EDF's safety objectives (definition of the three main safety functions, impact of the operation duration and of the coexistence of two generations for the safety functions), discusses how to manage the ageing phenomenon for replaceable and non-replaceable components

  2. Quasigluon lifetime and confinement from first principles

    Science.gov (United States)

    Siringo, Fabio

    2017-12-01

    The mass and the lifetime of a gluon are evaluated from first principles at a finite temperature across the deconfinement transition of pure SU(3) Yang-Mills theory, by a direct calculation of the pole of the propagator in the complex plane, using the finite temperature extension of a massive expansion in the Landau gauge. Even at T =0 , the quasigluon lifetime is finite, and the gluon is canceled from the asymptotic states, yielding a microscopic proof of confinement from first principles. Above the transition, the damping rate is a linear increasing function of temperature as predicted by standard perturbation theory.

  3. Lifetimes for some excited states of sodium

    International Nuclear Information System (INIS)

    Thomas, P.; Campos, J.

    1979-01-01

    The lifetimes of some s,p and d levels of sodium have been measured by the delayed coincidence method, using a single-photon counting technique. The results are compared with the calculated values of the present work, and with other results. The lifetimes of the ns, np, and levels up to n10; of the nf levels up to n-9;and of the ng, nh,n1 and nk levels up to n-8, have been calculated and the transition probabilities of lines with origin in these levels are given. (Author) 38 refs

  4. Measurement of the Bs0 lifetime

    Science.gov (United States)

    Buskulic, D.; de Bonis, I.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Minard, M.-N.; Odier, P.; Pietrzyk, B.; Ariztizabal, F.; Comas, P.; Crespo, J. M.; Efthymiopoulos, I.; Fernandez, E.; Fernandez-Bosman, M.; Gaitan, V.; Garrido, Ll.; Martinez, M.; Mattison, T.; Orteu, S.; Pacheco, A.; Padilla, C.; Pascual, A.; Creanza, D.; de Palma, M.; Farilla, A.; Iaselli, G.; Maggi, G.; Marinelli, N.; Natali, S.; Nuzzo, S.; Ranieri, A.; Raso, G.; Romano, F.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Chai, Y.; Hu, H.; Huang, D.; Huang, X.; Lin, J.; Wang, T.; Xie, Y.; Xu, D.; Xu, R.; Zhang, J.; Zhang, L.; Zhao, W.; Bonvicini, G.; Boudreau, J.; Casper, D.; Drevermann, H.; Forty, R. W.; Ganis, G.; Gay, C.; Girone, M.; Hagelberg, R.; Harvey, J.; Hilgart, J.; Jacobsen, R.; Jost, B.; Knobloch, J.; Lehraus, I.; Maggi, M.; Markou, C.; Mato, P.; Meinhard, H.; Minten, A.; Miquel, R.; Moser, H.-G.; Palazzi, P.; Pater, J. R.; Perlas, J. A.; Perrodo, P.; Pusztaszeri, J.-F.; Ranjard, F.; Rolandi, L.; Rothberg, J.; Ruan, T.; Saich, M.; Schlatter, D.; Schmelling, M.; Sefkow, F.; Tejessy, W.; Tomalin, I. R.; Veenhof, R.; Wachsmuth, H.; Wasserbaech, S.; Wiedenmann, W.; Wildish, T.; Witzeling, W.; Wotschack, J.; Ajaltouni, Z.; Bardadin-Otwinowska, M.; Barres, A.; Boyer, C.; Falvard, A.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Saadi, F.; Fearnley, T.; Hansen, J. B.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Johnson, S. D.; Møllerud, R.; Nilsson, B. S.; Kyriakis, A.; Simopoulou, E.; Siotis, I.; Vayaki, A.; Zachariadou, K.; Badier, J.; Blondel, A.; Bonneaud, G.; Brient, J. C.; Bourdon, P.; Fouque, G.; Passalacqua, L.; Rougé, A.; Rumpf, M.; Tanaka, R.; Verderi, M.; Videau, H.; Candlin, D. J.; Parsons, M. I.; Veitch, E.; Focardi, E.; Moneta, L.; Parrini, G.; Corden, M.; Delfino, M.; Georgiopoulos, C.; Jaffe, D. E.; Levinthal, D.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Cerutti, F.; Chiarella, V.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Pepe-Altarelli, M.; Salomone, S.; Colrain, P.; Ten Have, I.; Knowles, I. G.; Lynch, J. G.; Maitland, W.; Morton, W. T.; Raine, C.; Reeves, P.; Scarr, J. M.; Smith, K.; Smith, M. G.; Thompson, A. S.; Thorn, S.; Turnbull, R. M.; Brandl, B.; Braun, O.; Geweniger, C.; Graefe, G.; Hanke, P.; Hepp, V.; Karger, C.; Kluge, E. E.; Maumary, Y.; Putzer, A.; Rensch, B.; Stahl, A.; Tittel, K.; Wunsch, M.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Cattaneo, M.; Colling, D. J.; Dornan, P. J.; Hassard, J. F.; Lieske, N. M.; Moutoussi, A.; Nash, J.; Patton, S.; Payne, D. G.; Phillips, M. J.; San Martin, G.; Sedgbeer, J. K.; Wright, A. G.; Girtler, P.; Kuhn, D.; Rudolph, G.; Vogl, R.; Bowdery, C. K.; Brodbeck, T. J.; Finch, A. J.; Foster, F.; Hughes, G.; Jackson, D.; Keemer, N. R.; Nuttall, M.; Patel, A.; Sloan, T.; Snow, S. W.; Whelan, E. P.; Galla, A.; Greene, A. M.; Kleinknecht, K.; Raab, J.; Renk, B.; Sander, H.-G.; Schmidt, H.; Walther, S. M.; Wanke, R.; Wolf, B.; Bencheikh, A. M.; Benchouk, C.; Bonissent, A.; Calvet, D.; Carr, J.; Coyle, P.; Diaconu, C.; Drinkard, J.; Etienne, F.; Nicod, D.; Payre, P.; Ross, L.; Rousseau, D.; Schwemling, P.; Talby, M.; Adlung, S.; Assmann, R.; Bauer, C.; Blum, W.; Brown, D.; Cattaneo, P.; Dehning, B.; Dietl, H.; Dydak, F.; Frank, M.; Halley, A. W.; Jakobs, K.; Lauber, J.; Lütjens, G.; Lutz, G.; Männer, W.; Richter, R.; Schröder, J.; Schwarz, A. S.; Settles, R.; Seywerd, H.; Stierlin, U.; Stiegler, U.; Denis, R. St.; Wolf, G.; Alemany, R.; Boucrot, J.; Callot, O.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Janot, P.; Kimfn 19, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Musolino, G.; Schune, M.-H.; Veillet, J.-J.; Videau, I.; Abbaneo, D.; Bagliesi, G.; Batignani, G.; Bottigli, U.; Bozzi, C.; Calderini, G.; Carpinelli, M.; Ciocci, M. A.; Ciulli, V.; Dell'Orso, R.; Ferrante, I.; Fidecaro, F.; Foà, L.; Forti, F.; Giassi, A.; Giorgi, M. A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Mannelli, E. B.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Rizzo, G.; Sanguinetti, G.; Spagnolo, P.; Steinberger, J.; Tenchini, R.; Tonelli, G.; Triggiani, G.; Valassi, A.; Vannini, C.; Venturi, A.; Verdini, P. G.; Walsh, J.; Betteridge, A. P.; Gao, Y.; Green, M. G.; Johnson, D. L.; March, P. V.; Medcalf, T.; Mir, Ll. M.; Quazi, I. S.; Strong, J. A.; Bertin, V.; Botterill, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Edwards, M.; Norton, P. R.; Thompson, J. C.; Bloch-Devaux, B.; Colas, P.; Duarte, H.; Emery, S.; Kozanecki, W.; Lançon, E.; Lemaire, M. C.; Locci, E.; Marx, B.; Perez, P.; Rander, J.; Renardy, J.-F.; Rosowsky, A.; Roussarie, A.; Schuller, J.-P.; Schwindling, J.; Si Mohand, D.; Vallage, B.; Johnson, R. P.; Litke, A. M.; Taylor, G.; Wear, J.; Babbage, W.; Booth, C. N.; Buttar, C.; Cartwright, S.; Combley, F.; Dawson, I.; Thompson, L. F.; Barberio, E.; Böhrer, A.; Brandt, S.; Cowan, G.; Grupen, C.; Lutters, G.; Rivera, F.; Schäfer, U.; Smolik, L.; Bosisio, L.; Della Marina, R.; Giannini, G.; Gobbo, B.; Pitis, L.; Ragusa, F.; Bellantoni, L.; Chen, W.; Conway, J. S.; Feng, Z.; Ferguson, D. P. S.; Gao, Y. S.; Grahl, J.; Harton, J. L.; Hayes, O. J.; Nachtman, J. M.; Pan, Y. B.; Saadi, Y.; Schmitt, M.; Scott, I.; Sharma, V.; Shi, Z. H.; Turk, J. D.; Walsh, A. M.; Weber, F. V.; Lan Wu, Sau; Wu, X.; Zheng, M.; Zobernig, G.; Aleph Collaboration

    1994-02-01

    The lifetime of the Bs0 has been measured in a data sample of 8890000 hadronic events recorded with the ALEPH detector at LEP. After background subtraction 30.8 ± 6.9 events are attributed to the semileptonic decay of the Bs0 to a Ds- and an opposite-sign lepton. A maximum-likelihood fit to the distribution of the proper times of these events yields a Bs0 lifetime of τBs = 1.92 -0.35+0.45 ± 0.04 ps.

  5. Prompt Neutron Lifetime for the NBSR Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, A.L.; Diamond, D.

    2012-06-24

    In preparation for the proposed conversion of the National Institute of Standards and Technology (NIST) research reactor (NBSR) from high-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, certain point kinetics parameters must be calculated. We report here values of the prompt neutron lifetime that have been calculated using three independent methods. All three sets of calculations demonstrate that the prompt neutron lifetime is shorter for the LEU fuel when compared to the HEU fuel and longer for the equilibrium end-of-cycle (EOC) condition when compared to the equilibrium startup (SU) condition for both the HEU and LEU fuels.

  6. Spontaneous subcapsular and perirrenal hemorrhage

    International Nuclear Information System (INIS)

    Fuster, M.J.; Saez, J.; Perez-Paya, F.J.; Fernandez, F.

    1997-01-01

    To assess the role of CT in the etiologic diagnosis of spontaneous subcapsular and perirrenal hemorrhage. The CT findings are described in 13 patients presenting subcapsular and perirrenal hemorrhage. Those patients in whom the bleeding was not spontaneous were excluded. Surgical confirmation was obtained in nine cases. In 11 of the 13 cases (84.6%), involving five adenocarcinomas, five angiomyolipoma, two complicated cysts and one case of panarterities nodosa, CT disclosed the underlying pathology. In two cases (15.4%), it only revealed the extension of the hematoma, but gave no clue to its origin. CT is the technique of choice when spontaneous subcapsular and perirrenal hemorrhage is suspected since, in most cases, it reveals the underlying pathology. (Author)

  7. Spontaneous isolated celiac artery dissection

    Directory of Open Access Journals (Sweden)

    Tuba Cimilli Ozturk

    2011-01-01

    Full Text Available Dyspepsia with mild, stabbing epigastric discomfort without history of trauma is a very common symptom that emergency physicians see in their daily practice. Vascular emergencies, mostly the aortic dissection and aneurysm, are always described in the differential diagnosis with persistent symptoms. Isolated celiac artery dissection occurring spontaneously is a very rare diagnosis. The involvement of branch vessels is generally observed and patients show various clinical signs and symptoms according to the involved branch vessel. Here we are presenting a case with spontaneous isolated celiac artery dissection, without any branch vessel involvement or visceral damage, detected by computed tomography scans taken on admission.

  8. Spontaneous waves in muscle fibres

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Stefan; Kruse, Karsten [Department of Theoretical Physics, Saarland University, 66041 Saarbruecken (Germany); Max Planck Institute for the Physics of Complex Systems, Noethnitzer Street 38, 01187 Dresden (Germany)

    2007-11-15

    Mechanical oscillations are important for many cellular processes, e.g. the beating of cilia and flagella or the sensation of sound by hair cells. These dynamic states originate from spontaneous oscillations of molecular motors. A particularly clear example of such oscillations has been observed in muscle fibers under non-physiological conditions. In that case, motor oscillations lead to contraction waves along the fiber. By a macroscopic analysis of muscle fiber dynamics we find that the spontaneous waves involve non-hydrodynamic modes. A simple microscopic model of sarcomere dynamics highlights mechanical aspects of the motor dynamics and fits with the experimental observations.

  9. Lifetime Reliability Assessment of Concrete Slab Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    A procedure for lifetime assesment of the reliability of short concrete slab bridges is presented in the paper. Corrosion of the reinforcement is the deterioration mechanism used for estimating the reliability profiles for such bridges. The importance of using sensitivity measures is stressed...

  10. Lifetime measurements of the rare earths

    International Nuclear Information System (INIS)

    Stahnke, H.J.

    1981-01-01

    The lifetime of excited energy levels of Praseodymium, Neodymium, Gadolinium, Holmium and Erbium are measured. The measurements were done on atomic beams excited by laser radiation. The experimental results allow an interpretation of the electronic structure of the rare earths. (BEF)

  11. Atmospheric lifetimes of selected fluorinated ether compounds

    DEFF Research Database (Denmark)

    Heathfield, A.E.; Anastasi, C.; Pagsberg, Palle Bjørn

    1998-01-01

    Atmospheric lifetimes have been estimated for a selection of ethers, the latter representing a class of compounds being considered as replacements for chlorofluorocarbons. The estimates are based on laboratory measurements of rate constants for the reaction of the OH radical with the ethers, and ...

  12. The College Payoff: Education, Occupations, Lifetime Earnings

    Science.gov (United States)

    Carnevale, Anthony P.; Rose, Stephen J.; Cheah, Ban

    2011-01-01

    A college degree pays off--but by just how much? In this report from the Georgetown University Center on Education and the Workforce, the authors examine just what a college degree is worth--and what else besides a degree might influence an individual's potential earnings. This report examines lifetime earnings for all education levels and…

  13. Determination of the D mesons lifetimes

    International Nuclear Information System (INIS)

    Josa Mutuberria, M.I.

    1990-01-01

    The results from the experiment NA27, performed in the North Area of the Super Proton Synchrotron at CERN are presented. The experimental set up was the small, high resolution, rapid cyling bubble chamber LEBC coupled with the European Hybrid Spectrometer (EHS). More than 2 millions pictures were taken, with 1015000 in teractions in hydrogen. The stastistical sensitivity of the experiment was 38.5 events/μb. A clean sample of 700 charm particle decays was obtained. Estimators with minimal systematic and statistical errors are developed for the determination of the lifetimes of short-lived particles whose individual momenta are unknown. These estimators make use of the measured decay lengths and the a priori known production characteristics. In this way, it is possible to include identified but not fully reconstructed charm decays in the sample to determine their lifetime. The properties of these estimators were extensively studied by means of Montecarlo simulation. The detection of the short-lived particles through the impact parameter of their charged decay products leads to additional complications which are taken into account. The biases and statistical errors inherent in using simpler approximate lifetime estimators are also discussed. These estimators are applied to determine the lifetime of the D o and D +- mesons using the charm data sample from NA27. (Author)

  14. Highly charged ions trapping for lifetime measurements

    International Nuclear Information System (INIS)

    Attia, D.

    2007-10-01

    A new experimental setup dedicated to highly charged ion trapping is presented in this work. The final goal is to perform lifetime measurement of metastable states produced by our ECR (Electron Cyclotron Resonance) ion source. Lifetimes to be measured are in the range of a few ms and more. We have measured the lifetimes of the M1 transitions of the metastable states of Ar 9+ , Ar 13+ and Ar 14+ . These measurements are useful to test the N-body problem in the relativistic range. The trap we have built, was designed a few years ago at the Weizman Institute in Israel, it allows ions with an energy of several keV to be trapped for lifetimes of about 1 second. This trap was originally designed to study the dynamics of excited molecules. We have shown for the first time how the trap operates and that it can operate with highly charged ions. We have studied the beam dynamics of highly charged ions and the trap has been tested with various species of ions and different charge states: from O + to O 6+ , from Ar 8+ to Ar 13+ , and from Kr 13+ to Kr 20+

  15. Lifetime socio-economic position and depression

    DEFF Research Database (Denmark)

    Osler, Merete; Bruunsgaard, Helle; Mortensen, Erik Lykke

    2015-01-01

    Background: Little is known about the influence of lifetime socio-economic position (SEP) on adult depression. We examined the association of SEP during the life course with depressive mood in late midlife and explored whether cognitive function at age 20, health-related behaviour and inflammatory...

  16. Design Wave Height Related to Structure Lifetime

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    1996-01-01

    the structure lifetime. This includes the statistical vagrancy of nature, sample variability and the uncertainty due to measurement or hindcast error. Moreover, based on the discussion on the statistical vagrancy of nature, a formula for the calculation of encounter probability is presented....

  17. Design Wave Height Related to Structure Lifetime

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Z.

    1999-01-01

    the structure lifetime. This includes the statistical vagrancy of nature, sample variability and the uncertainty due to measurement or hindcast error. Moreover, based on the discussion on the statistical vagrancy of nature, a formula for the calculation of encounter probability is presented....

  18. Overview of Field Experience - Degradation Rates & Lifetimes

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, Dirk; Kurtz, Sarah

    2015-09-14

    The way a PV module fails may depend not only on its design and the materials used in its construction, but also on the weather it experiences, the way it is mounted, and the quality control during its manufacture. This presentation gives an overview of Field Experience - what degradation rates and what lifetimes are being observed in various regions.

  19. Genetic improvement of sow lifetime productivity

    Science.gov (United States)

    Sow lifetime productivity is a complex, yet important trait, that would benefit commercial populations if improved. It has been estimated that a sow must produce 3 litters to cover the cost of replacement; yet, nearly half of the gilts retained for breeding are removed prior to producing 3 litters r...

  20. Smoking expands expected lifetime with musculoskeletal disease

    DEFF Research Database (Denmark)

    Brønnum-Hansen, Henrik; Juel, Knud

    2003-01-01

    By indirect estimation of mortality from smoking and life table methods we estimated expected lifetime without musculoskeletal diseases among never smokers, ex-smokers, and smokers. We found that although life expectancy of a heavy smoker is 7 years shorter than that of a never smoker, heavy...

  1. Updated measurement of the $\\tau$ lepton lifetime

    CERN Document Server

    Barate, R; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Nief, J Y; Pietrzyk, B; Casado, M P; Chmeissani, M; Comas, P; Crespo, J M; Delfino, M C; Fernández, E; Fernández-Bosman, M; Garrido, L; Juste, A; Martínez, M; Merino, G; Miquel, R; Mir, L M; Padilla, C; Park, I C; Pascual, A; Perlas, J A; Riu, I; Sánchez, F; Teubert, F; Colaleo, A; Creanza, D; De Palma, M; Gelao, G; Iaselli, Giuseppe; Maggi, G; Maggi, M; Marinelli, N; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Alemany, R; Becker, U; Bazarko, A O; Bright-Thomas, P G; Cattaneo, M; Cerutti, F; Dissertori, G; Drevermann, H; Forty, Roger W; Frank, M; Hagelberg, R; Hansen, J B; Harvey, J; Janot, P; Jost, B; Kneringer, E; Knobloch, J; Lehraus, Ivan; Mato, P; Minten, Adolf G; Moneta, L; Pacheco, A; Pusztaszeri, J F; Ranjard, F; Rizzo, G; Rolandi, Luigi; Rousseau, D; Schlatter, W D; Schmitt, M; Schneider, O; Tejessy, W; Tomalin, I R; Wachsmuth, H W; Wagner, A; Ajaltouni, Ziad J; Barrès, A; Boyer, C; Falvard, A; Ferdi, C; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rosnet, P; Rossignol, J M; Fearnley, Tom; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Blondel, A; Bonneaud, G R; Brient, J C; Bourdon, P; Rougé, A; Rumpf, M; Valassi, Andrea; Verderi, M; Videau, H L; Candlin, D J; Parsons, M I; Focardi, E; Parrini, G; Zachariadou, K; Corden, M; Georgiopoulos, C H; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Casper, David William; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Passalacqua, L; Pepé-Altarelli, M; Curtis, L; Dorris, S J; Halley, A W; Knowles, I G; Lynch, J G; O'Shea, V; Raine, C; Scarr, J M; Smith, K; Teixeira-Dias, P; Thompson, A S; Thomson, E; Thomson, F; Turnbull, R M; Buchmüller, O L; Dhamotharan, S; Geweniger, C; Graefe, G; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Sommer, J; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Dornan, Peter J; Girone, M; Goodsir, S M; Martin, E B; Moutoussi, A; Nash, J; Sedgbeer, J K; Spagnolo, P; Stacey, A M; Williams, M D; Ghete, V M; Girtler, P; Kuhn, D; Rudolph, G; Betteridge, A P; Bowdery, C K; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Jones, R W L; Sloan, Terence; Williams, M I; Galla, A; Giehl, I; Greene, A M; Hoffmann, C; Jakobs, K; Kleinknecht, K; Quast, G; Renk, B; Rohne, E; Sander, H G; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Bujosa, G; Carr, J; Coyle, P; Diaconu, C A; Etienne, F; Konstantinidis, N P; Leroy, O; Motsch, F; Payre, P; Talby, M; Sadouki, A; Thulasidas, M; Trabelsi, K; Aleppo, M; Antonelli, M; Ragusa, F; Berlich, R; Blum, Walter; Büscher, V; Dietl, H; Ganis, G; Gotzhein, C; Kroha, H; Lütjens, G; Lutz, Gerhard; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Saint-Denis, R; Stenzel, H; Wiedenmann, W; Wolf, G; Boucrot, J; Callot, O; Chen, S; Choi, Y; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Höcker, A; Jacholkowska, A; Jacquet, M; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Nikolic, I A; Schune, M H; Simion, S; Tournefier, E; Veillet, J J; Videau, I; Zerwas, D; Azzurri, P; Bagliesi, G; Batignani, G; Bettarini, S; Bozzi, C; Calderini, G; Carpinelli, M; Ciocci, M A; Ciulli, V; Dell'Orso, R; Fantechi, R; Ferrante, I; Foà, L; Forti, F; Giassi, A; Giorgi, M A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, Fabrizio; Sanguinetti, G; Sciabà, A; Steinberger, Jack; Tenchini, Roberto; Tonelli, G; Vannini, C; Venturi, A; Verdini, P G; Blair, G A; Bryant, L M; Chambers, J T; Gao, Y; Green, M G; Medcalf, T; Perrodo, P; Strong, J A; Von Wimmersperg-Töller, J H; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Norton, P R; Thompson, J C; Wright, A E; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Trabelsi, A; Vallage, B; Black, S N; Dann, J H; Johnson, R P; Kim, H Y; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Boswell, R; Brew, C A J; Cartwright, S L; Combley, F; Kelly, M S; Lehto, M H; Newton, W M; Reeve, J; Thompson, L F; Böhrer, A; Brandt, S; Cowan, G D; Grupen, Claus; Lutters, G; Saraiva, P; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Pütz, J; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Charles, E; Elmer, P; Ferguson, D P S; González, S; Greening, T C; Hayes, O J; Hu, H; Jin, S; McNamara, P A; Nachtman, J M; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Walsh, J; Wu Sau Lan; Wu, X; Yamartino, J M; Zobernig, G

    1997-01-01

    A new measurement of the mean lifetime of the tau lepton is presented. Three different analysis methods are applied to a sample of 90000 tau pairs, collected in 1993 and 1994 with the ALEPH detector at LEP. The average of this measurement and those previously published by ALEPH is tau_tau = 290.1 +- 1.5 +- 1.1 fs.

  2. Updated measurement of the τ lepton lifetime

    Science.gov (United States)

    ALEPH Collaboration; Barate, R.; Buskulic, D.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Lucotte, A.; Minard, M.-N.; Nief, J.-Y.; Pietrzyk, B.; Casado, M. P.; Chmeissani, M.; Comas, P.; Crespo, J. M.; Delfino, M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, Ll.; Juste, A.; Martinez, M.; Merino, G.; Miquel, R.; Mir, Ll. M.; Padilla, C.; Park, I. C.; Pascual, A.; Perlas, J. A.; Riu, I.; Sanchez, F.; Teubert, F.; Colaleo, A.; Creanza, D.; de Palma, M.; Gelao, G.; Iaselli, G.; Maggi, G.; Maggi, M.; Marinelli, N.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Alemany, R.; Becker, U.; Bazarko, A. O.; Bright-Thomas, P.; Cattaneo, M.; Cerutti, F.; Dissertori, G.; Drevermann, H.; Forty, R. W.; Frank, M.; Hagelberg, R.; Hansen, J. B.; Harvey, J.; Janot, P.; Jost, B.; Kneringer, E.; Knobloch, J.; Lehraus, I.; Mato, P.; Minten, A.; Moneta, L.; Pacheco, A.; Pusztaszeri, J.-F.; Ranjard, F.; Rizzo, G.; Rolandi, L.; Rousseau, D.; Schlatter, D.; Schmitt, M.; Schneider, O.; Tejessy, W.; Tomalin, I. R.; Wachsmuth, H.; Wagner, A.; Ajaltouni, Z.; Barrès, A.; Boyer, C.; Falvard, A.; Ferdi, C.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Rosnet, P.; Rossignol, J.-M.; Fearnley, T.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Nilsson, B. S.; Rensch, B.; Wäänänen, A.; Daskalakis, G.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Siotis, I.; Vayaki, A.; Blondel, A.; Bonneaud, G.; Brient, J. C.; Bourdon, P.; Rougé, A.; Rumpf, M.; Valassi, A.; Verderi, M.; Videau, H.; Candlin, D. J.; Parsons, M. I.; Focardi, E.; Parrini, G.; Zachariadou, K.; Corden, M.; Georgiopoulos, C.; Jaffe, D. E.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Casper, D.; Chiarella, V.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Passalacqua, L.; Pepe-Altarelli, M.; Curtis, L.; Dorris, S. J.; Halley, A. W.; Knowles, I. G.; Lynch, J. G.; O'Shea, V.; Raine, C.; Scarr, J. M.; Smith, K.; Teixeira-Dias, P.; Thompson, A. S.; Thomson, E.; Thomson, F.; Turnbull, R. M.; Buchmüller, O.; Dhamotharan, S.; Geweniger, C.; Graefe, G.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E. E.; Putzer, A.; Sommer, J.; Tittel, K.; Werner, S.; Wunsch, M.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Dornan, P. J.; Girone, M.; Goodsir, S.; Martin, E. B.; Moutoussi, A.; Nash, J.; Sedgbeer, J. K.; Spagnolo, P.; Stacey, A. M.; Williams, M. D.; Ghete, V. M.; Girtler, P.; Kuhn, D.; Rudolph, G.; Betteridge, A. P.; Bowdery, C. K.; Colrain, P.; Crawford, G.; Finch, A. J.; Foster, F.; Hughes, G.; Jones, R. W. L.; Sloan, T.; Williams, M. I.; Galla, A.; Giehl, I.; Greene, A. M.; Hoffmann, C.; Jakobs, K.; Kleinknecht, K.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.-G.; van Gemmeren, P.; Zeitnitz, C.; Aubert, J. J.; Benchouk, C.; Bonissent, A.; Bujosa, G.; Carr, J.; Coyle, P.; Diaconu, C.; Etienne, F.; Konstantinidis, N.; Leroy, O.; Motsch, F.; Payre, P.; Talby, M.; Sadouki, A.; Thulasidas, M.; Trabelsi, K.; Aleppo, M.; Antonelli, M.; Ragusa, F.; Berlich, R.; Blum, W.; Büscher, V.; Dietl, H.; Ganis, G.; Gotzhein, C.; Kroha, H.; Lütjens, G.; Lutz, G.; Männer, W.; Moser, H.-G.; Richter, R.; Rosado-Schlosser, A.; Schael, S.; Settles, R.; Seywerd, H.; St. Denis, R.; Stenzel, H.; Wiedenmann, W.; Wolf, G.; Boucrot, J.; Callot, O.; Chen, S.; Choi, Y.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Höcker, A.; Jacholkowska, A.; Jacquet, M.; Kim, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Nikolic, I.; Schune, M.-H.; Simion, S.; Tournefier, E.; Veillet, J.-J.; Videau, I.; Zerwas, D.; Azzurri, P.; Bagliesi, G.; Batignani, G.; Bettarini, S.; Bozzi, C.; Calderini, G.; Carpinelli, M.; Ciocci, M. A.; Ciulli, V.; dell'Orso, R.; Fantechi, R.; Ferrante, I.; Foà, L.; Forti, F.; Giassi, A.; Giorgi, M. A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Sanguinetti, G.; Sciabà, A.; Steinberger, J.; Tenchini, R.; Tonelli, G.; Vannini, C.; Venturi, A.; Verdini, P. G.; Blair, G. A.; Bryant, L. M.; Chambers, J. T.; Gao, Y.; Green, M. G.; Medcalf, T.; Perrodo, P.; Strong, J. A.; von Wimmersperg-Toeller, J. H.; Botterill, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Norton, P. R.; Thompson, J. C.; Wright, A. E.; Bloch-Devaux, B.; Colas, P.; Emery, S.; Kozanecki, W.; Lançon, E.; Lemaire, M. C.; Locci, E.; Perez, P.; Rander, J.; Renardy, J.-F.; Roussarie, A.; Schuller, J.-P.; Schwindling, J.; Trabelsi, A.; Vallage, B.; Black, S. N.; Dann, J. H.; Johnson, R. P.; Kim, H. Y.; Litke, A. M.; McNeil, M. A.; Taylor, G.; Booth, C. N.; Boswell, R.; Brew, C. A. J.; Cartwright, S.; Combley, F.; Kelly, M. S.; Lehto, M.; Newton, W. M.; Reeve, J.; Thompson, L. F.; Böhrer, A.; Brandt, S.; Cowan, G.; Grupen, C.; Lutters, G.; Saraiva, P.; Smolik, L.; Stephan, F.; Apollonio, M.; Bosisio, L.; della Marina, R.; Giannini, G.; Gobbo, B.; Musolino, G.; Putz, J.; Rothberg, J.; Wasserbaech, S.; Armstrong, S. R.; Charles, E.; Elmer, P.; Ferguson, D. P. S.; González, S.; Greening, T. C.; Hayes, O. J.; Hu, H.; Jin, S.; McNamara, P. A., III; Nachtman, J. M.; Nielsen, J.; Orejudos, W.; Pan, Y. B.; Saadi, Y.; Scott, I. J.; Walsh, J.; Wu, Sau Lan; Wu, X.; Yamartino, J. M.; Zobernig, G.

    1997-11-01

    A new measurement of the mean lifetime of the τ lepton is presented. Three different analysis methods are applied to a sample of 90 000 τ pairs, collected in 1993 and 1994 with the ALEPH detector at LEP. The average of this measurement and those previously published by ALEPH is ττ=290.1+/-1.5+/-1.1 fs.

  3. Lifetime Modeling of Thermal Barrier Coatings

    NARCIS (Netherlands)

    Hille, T.S.

    2009-01-01

    Thermal barrier coatings (TBCs) are applied in gas turbines to enhance their thermal efficiency by isolating the metallic components from the aggressive hot gas. TBC lifetime is limited by damage processes originating at internal interfaces, which may ultimately lead to delamination and spallation.

  4. Lifetime oriented maintenance planning in the Netherlands

    NARCIS (Netherlands)

    Straub, A.

    2003-01-01

    In this paper we set up a framework for lifetime oriented maintenance planning as an outcome and input for strategic housing stock management. The maintenance planning holds maintenance activities and costs in the longer term. We consider the maintenance planning as a tool to calculate and implement

  5. Lifetime tests for MAC vertex chamber

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, H.N.

    1986-07-01

    A vertex chamber for MAC was proposed to increase precision in the measurement of the B hadron and tau lepton lifetimes. Thin-walled aluminized mylar drift tubes were used for detector elements. A study of radiation hardness was conducted under the conditions of the proposed design using different gases and different operating conditions. (LEW)

  6. Materials Education: Opportunities over a Lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Iver E.; Schwartz, Lyle H.; Faber, Katherine T.; Cargill III, G. Slade; Houston, Betsy

    2003-10-28

    A report, in the form of abbreviated notes, of the 17th Biennial Conference on National Materials Policy ''Materials Education: Opportunities over a Lifetime'' held May 20-21, 2002 in College Park, MD, sponsored by the Federation of Materials Societies and the University Materials Council.

  7. Increasing the lifetime of fuel cell catalysts

    NARCIS (Netherlands)

    Latsuzbaia, R.

    2015-01-01

    In this thesis, I discuss a novel idea of fuel cell catalyst regeneration to increase lifetime of the PEM fuel cell electrode/catalyst operation and, therefore, reduce the catalyst costs. As many of the catalyst degradation mechanisms are difficult to avoid, the regeneration is alternative option to

  8. Human Papillomavirus Infection as a Possible Cause of Spontaneous Abortion and Spontaneous Preterm Delivery

    DEFF Research Database (Denmark)

    Ambühl, Lea Maria Margareta; Baandrup, Ulrik; Dybkær, Karen

    2016-01-01

    , and 10.9% (95% CI; 10.1–11.7) for umbilical cord blood. Summary estimates for HPV prevalence of spontaneous abortions and spontaneous preterm deliveries, in cervix (spontaneous abortions: 24.5%, and pretermdeliveries: 47%, resp.) and placenta (spontaneous abortions: 24.9%, and preterm deliveries: 50......%, resp.), were identified to be higher compared to normal full-term pregnancies (푃 spontaneous abortion, spontaneous preterm...

  9. Spontaneous emission by moving atoms

    International Nuclear Information System (INIS)

    Meystre, P.; Wilkens, M.

    1994-01-01

    It is well known that spontaneous emission is not an intrinsic atomic property, but rather results from the coupling of the atom to the vacuum modes of the electromagnetic field. As such, it can be modified by tailoring the electromagnetic environment into which the atom can radiate. This was already realized by Purcell, who noted that the spontaneous emission rate can be enhanced if the atom placed inside a cavity is resonant with one of the cavity is resonant with one of the cavity modes, and by Kleppner, who discussed the opposite case of inhibited spontaneous emission. It has also been recognized that spontaneous emission need not be an irreversible process. Indeed, a system consisting of a single atom coupled to a single mode of the electromagnetic field undergoes a periodic exchange of excitation between the atom and the field. This periodic exchange remains dominant as long as the strength of the coupling between the atom and a cavity mode is itself dominant. 23 refs., 6 figs

  10. Spontaneous Development of Moral Concepts

    Science.gov (United States)

    Siegal, M.

    1975-01-01

    Moral competence is more difficult to attain than scientific competence. Since language comprehension plays a central role in conceptual development, and moral language is difficult to learn, there is a common deficiency in moral conceptual development. This suggests a theory of non-spontaneous solutions to moral problems. (Author/MS)

  11. Shell theorem for spontaneous emission

    DEFF Research Database (Denmark)

    Kristensen, Philip Trøst; Mortensen, Jakob Egeberg; Lodahl, Peter

    2013-01-01

    and therefore is given exactly by the dipole approximation theory. This surprising result is a spontaneous emission counterpart to the shell theorems of classical mechanics and electrostatics and provides insights into the physics of mesoscopic emitters as well as great simplifications in practical calculations....

  12. Prediction of Spontaneous Preterm Birth

    NARCIS (Netherlands)

    Dijkstra, Karolien

    2002-01-01

    Preterm birth is a leading cause of neonatal morbidity and mortality. It is a major goal in obstetrics to lower the incidence of spontaneous preterm birth (SPB) and related neonatal morbidity and mortality. One of the principal objectives is to discover early markers that would allow us to identify

  13. EAMJ Dec. Spontaneous.indd

    African Journals Online (AJOL)

    2008-12-12

    Dec 12, 2008 ... surgical abortion at one month gestation without any complication. The second pregnancy which was a year prior resulted in a spontaneous miscarriage at two months followed by evacuation of retained products of conception with no post abortion complications. Antibiotics were taken following both.

  14. Spontaneous fission of superheavy nuclei

    Indian Academy of Sciences (India)

    the Yukawa-plus-exponential potential. The microscopic shell and pairing corrections are obtained using the Strutinsky and BCS approaches and the cranking formulae yield the inertia tensor. Finally, the WKB method is used to calculate penetrabilities and spontaneous fission half-lives. Calculations are performed for the ...

  15. The association of lifetime insight and cognition in psychosis.

    Science.gov (United States)

    Sánchez-Torres, Ana M; Zarzuela, Amalia; Peralta, Victor; Cuesta, Manuel J

    2015-03-01

    Poor insight has been related to poor course in psychosis. However, the role of cognition in insight remains unclear. The aim of this study was to examine the influence of cognition and lifetime psychopathological dimensions on insight in psychosis. We followed up 42 patients with psychotic disorders over 10years. Lifetime psychopathological dimensions and cognitive performance were assessed. Patients were divided into two groups by lifetime patterns of insight and compared with 42 healthy volunteers. Lower IQ and poorer social cognition were associated with higher risks of poorer lifetime insight of feeling ill and global insight respectively. Lifetime negative symptoms were associated with a higher risk of poorer lifetime insight into symptoms. Lifetime lack of insight is independent of cognitive impairment in specific domains, except for social cognition. Higher IQ may contribute to better lifetime awareness of illness, while better ability to manage emotions is involved in lifetime global insight. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Spontaneous resolution of asymptomatic Chlamydia trachomatis in pregnancy.

    Science.gov (United States)

    Sheffield, Jeanne S; Andrews, Williams W; Klebanoff, Mark A; Macpherson, Cora; Carey, J Christopher; Ernest, J M; Wapner, Ronald J; Trout, Wayne; Moawad, Atef; Miodovnik, Menachem; Sibai, Baha; Varner, Michael W; Caritis, Steve N; Dombrowski, Mitchell; Langer, Oded; O'Sullivan, Mary J

    2005-03-01

    We sought to estimate the rate of spontaneous resolution of asymptomatic Chlamydia trachomatis in pregnancy and to evaluate factors associated with its resolution. A cohort of women enrolled in a large multicenter randomized bacterial vaginosis antibiotic trial (metronidazole versus placebo) that, when randomly allocated, had asymptomatic C trachomatis diagnosed by urine ligase chain reaction (from frozen archival specimens) between 16(0/7) and 23(6/7) weeks were included. The urine ligase chain reaction is a highly accurate predictor of genital tract chlamydial infection. A follow-up ligase chain reaction was performed between 24(0/7) and 29(6/7) weeks. A total of 1,953 women were enrolled in the original antibiotic trial; 1,547 (79%) had ligase chain reaction performed both at randomization and follow-up. Women receiving antibiotics effective against Chlamydia between randomization and follow-up or having symptomatic Chlamydia infection were excluded (26 women). Of the 140 women (9%) who were diagnosed as positive via the initial ligase chain reaction assay, 61 (44%) had spontaneous resolution of Chlamydia by the follow-up ligase chain reaction assay. Factors associated with spontaneous resolution included older age (P = .02), more than 5 weeks from randomization to follow-up (P = .02), and a greater number of lifetime sexual partners (P = .02). Using a logistic regression model, maternal age and a greater-than-5-week follow-up interval remained significant; for every 5-year increase in maternal age, the odds of a positive result on the ligase chain reaction test at follow-up decreased by 40% (odds ratio 0.6; 95% confidence interval 0.4-0.9). Race, substance abuse, parity, and treatment with metronidazole were not associated with spontaneous resolution. Gram stain score and vaginal pH at randomization and follow-up also were not associated. The prevalence of asymptomatic C trachomatis in pregnancy was 9%; infection resolved spontaneously in almost half of these

  17. Spontaneous Retropharyngeal Emphysema: A Case Report | Chi ...

    African Journals Online (AJOL)

    ... is a rare clinical condition in pediatric otolaryngology. The predominant symptoms are sore throat, odynophagia, dysphagia, and neck pain. Here, we report a case of spontaneous retropharyngeal emphysema. Keywords: Iatrogenic injury, retropharyngeal emphysema, spontaneous retropharyngeal emphysem, trauma ...

  18. La maladie de Grisel : Spontaneous atlantoaxial subluxation

    NARCIS (Netherlands)

    Meek, MF; Robinson, PH; Hermens, RAEC

    Objective: "La maladie de Grisel" (Grisel's syndrome) is a spontaneously occurring atlantoaxial subluxation with torticollis. We present a case of atlantoaxial subluxation occurring in a 20-year period of pharyngoplasty surgery. The occurrence of a "spontaneous" atlantoaxial subluxation after oral

  19. Lifetime and residual strength of materials

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    1997-01-01

    The DVM-theory (Damaged Viscoelastic Material) previously developed by the author to predict lifetime of wood subjected to static loads is further developed in this paper such that harmonic load variations can also be considered. Lifetime (real time or number of cycles) is predicted as a function...... of load amplitude, load average, fractional time under maximum load, and load frequency.The analysis includes prediction of residual strength (re-cycle strength) during the process of load cycling. It is concluded that number of cycles to failure is a very poor design criterion. It is demonstrated how...... the theory developed can be generalized also to consider non-harmonic load variations.Algorithms are presented for design purposes which may be suggested as qualified alternatives to the Palmgren-Miner's methods normally used in fatigue analysis of materials under arbitrary load variations. Prediction...

  20. New parameters influencing hydraulic runner lifetime

    Science.gov (United States)

    Sabourin, M.; Thibault, D.; Bouffard, D. A.; Lévesque, M.

    2010-08-01

    Traditionally, hydraulic runner mechanical design is based on calculation of static stresses. Today, validation of hydraulic runner design in terms of reliability requires taking into account the fatigue effect of dynamics loads. A damage tolerant approach based on fracture mechanics is the method chosen by Alstom and Hydro-Québec to study fatigue damage in runners. This requires a careful examination of all factors influencing material fatigue behavior. Such material behavior depends mainly on the chemical composition, microstructure and thermal history of the component, and on the resulting residual stresses. Measurement of fracture mechanics properties of various steels have demonstrated that runner lifetime can be significantly altered by differences in the manufacturing process, although remaining in accordance with agreed practices and standards such as ASTM. Carbon content and heat treatment are suspected to influence fatigue lifetime. This will have to be investigated by continuing the current research.

  1. A Precise Measurement of the Tau Lifetime

    CERN Document Server

    Abdallah, J; Adam, W; Adzic, P; Albrecht, T; Alderweireld, T; Alemany-Fernandez, R; Allmendinger, T; Allport, P P; Amaldi, Ugo; Amapane, N; Amato, S; Anashkin, E; Andreazza, A; Andringa, S; Anjos, N; Antilogus, P; Apel, W D; Arnoud, Y; Ask, S; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Ballestrero, A; Bambade, P; Barbier, R; Bardin, Dimitri Yuri; Barker, G J; Baroncelli, A; Battaglia, Marco; Baubillier, M; Becks, K H; Begalli, M; Behrmann, A; Ben-Haim, E; Benekos, N C; Benvenuti, Alberto C; Bérat, C; Berggren, M; Berntzon, L; Bertrand, D; Besançon, M; Besson, N; Bloch, D; Blom, M; Bluj, M; Bonesini, M; Boonekamp, M; Booth, P S L; Borisov, G; Botner, O; Bouquet, B; Bowcock, T J V; Boyko, I; Bracko, M; Brenner, R; Brodet, E; Brückman, P; Brunet, J M; Bugge, L; Buschmann, P; Calvi, M; Camporesi, T; Canale, V; Carena, F; Castro, N; Cavallo, F R; Chapkin, M M; Charpentier, P; Checchia, P; Chierici, R; Shlyapnikov, P; Chudoba, J; Chung, S U; Cieslik, K; Collins, P; Contri, R; Cosme, G; Cossutti, F; Costa, M J; Crennell, D J; Cuevas-Maestro, J; D'Hondt, J; Dalmau, J; Da Silva, T; Da Silva, W; Della Ricca, G; De Angelis, A; de Boer, Wim; De Clercq, C; De Lotto, B; De Maria, N; De Min, A; De Paula, L S; Di Ciaccio, L; Di Simone, A; Doroba, K; Drees, J; Dris, M; Eigen, G; Ekelöf, T J C; Ellert, M; Elsing, M; Espirito-Santo, M C; Fanourakis, G K; Fassouliotis, D; Feindt, M; Fernández, J; Ferrer, A; Ferro, F; Flagmeyer, U; Föth, H; Fokitis, E; Fulda-Quenzer, F; Fuster, J A; Gandelman, M; García, C; Gavillet, P; Gazis, E N; Gokieli, R; Golob, B; Gómez-Ceballos, G; Gonçalves, P; Graziani, E; Grosdidier, G; Grzelak, K; Guy, J; Haag, C; Hallgren, A; Hamacher, K; Hamilton, K; Haug, S; Hauler, F; Hedberg, V; Hennecke, M; Herr, H; Hoffman, J; Holmgren, S O; Holt, P J; Houlden, M A; Hultqvist, K; Jackson, J N; Jarlskog, G; Jarry, P; Jeans, D; Johansson, E K; Johansson, P D; Jonsson, P; Joram, C; Jungermann, L; Kapusta, F; Katsanevas, S; Katsoufis, E C; Kernel, G; Kersevan, B P; Kerzel, U; Kiiskinen, A P; King, B T; Kjaer, N J; Kluit, P; Kokkinias, P; Kourkoumelis, C; Kuznetsov, O; Krumshtein, Z; Kucharczyk, M; Lamsa, J; Leder, G; Ledroit, F; Leinonen, L; Leitner, R; Lemonne, J; Lepeltier, V; Lesiak, T; Liebig, W; Liko, D; Lipniacka, A; Lopes, J H; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J; Malek, A; Maltezos, S; Mandl, F; Marco, J; Marco, R; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Martínez-Rivero, C; Masik, J; Mastroyiannopoulos, N; Matorras, F; Matteuzzi, C; Mazzucato, F; Mazzucato, M; McNulty, R; Meroni, C; Migliore, E; Mitaroff, W A; Mjörnmark, U; Moa, T; Moch, M; Mönig, K; Monge, R; Montenegro, J; Moraes, D; Moreno, S; Morettini, P; Müller, U; Münich, K; Mulders, M; Mundim, L; Murray, W; Muryn, B; Myatt, G; Myklebust, T; Nassiakou, M; Navarria, Francesco Luigi; Nawrocki, K; Nicolaidou, R; Nikolenko, M; Oblakowska-Mucha, A; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, R; Österberg, K; Ouraou, A; Oyanguren, A; Paganoni, M; Paiano, S; Palacios, J P; Palka, H; Papadopoulou, T D; Pape, L; Parkes, C; Parodi, F; Parzefall, U; Passeri, A; Passon, O; Peralta, L; Perepelitsa, V F; Perrotta, A; Petrolini, A; Piedra, J; Pieri, L; Pierre, F; Pimenta, M; Piotto, E; Podobnik, T; Poireau, V; Pol, M E; Polok, G; Pozdnyakov, V; Pukhaeva, N; Pullia, A; Rames, J; Read, A; Rebecchi, P; Rehn, J; Reid, D; Reinhardt, R; Renton, P B; Richard, F; Rídky, J; Rivero, M; Rodríguez, D; Romero, A; Ronchese, P; Roudeau, P; Rovelli, T; Ruhlmann-Kleider, V; Ryabtchikov, D; Sadovskii, A; Salmi, L; Salt, J; Sander, C; Savoy-Navarro, A; Schwickerath, U; Segar, A; Sekulin, R L; Siebel, M; Sissakian, A N; Smadja, G; Smirnova, O G; Sokolov, A; Sopczak, A; Sosnowski, R; Spassoff, Tz; Stanitzki, M; Stocchi, A; Strauss, J; Stugu, B; Szczekowski, M; Szeptycka, M; Szumlak, T; Tabarelli de Fatis, T; Taffard, A C; Tegenfeldt, F; Timmermans, J; Tkatchev, L G; Tobin, M; Todorovova, S; Tomé, B; Tonazzo, A; Tortosa, P; Travnicek, P; Treille, D; Tristram, G; Trochimczuk, M; Troncon, C; Turluer, M L; Tyapkin, I A; Tyapkin, P; Tzamarias, S; Uvarov, V; Valenti, G; van Dam, P; Van Eldik, J; Van Lysebetten, A; Van Remortel, N; Van Vulpen, I; Vegni, G; Veloso, F; Venus, W A; Verdier, P; Verzi, V; Vilanova, D; Vitale, L; Vrba, V; Wahlen, H; Washbrook, A J; Weiser, C; Wicke, D; Wickens, J H; Wilkinson, G; Winter, M; Witek, M; Yushchenko, O P; Zalewska-Bak, A; Zalewski, P; Zavrtanik, D; Zhuravlov, V; Zimin, N I; Zintchenko, A; Zupan, M

    2004-01-01

    The tau lepton lifetime has been measured with the e+e- -> tau+tau- events collected by the DELPHI detector at LEP in the years 1991-1995. Three different methods have been exploited, using both one-prong and three-prong tau decay channels. Two measurements have been made using events in which both taus decay to a single charged particle. Combining these measurements gave tau_tau (1 prong) = 291.8 +/- 2.3 (stat) +/- 1.5 (sys) fs. A third measurement using taus which decayed to three charged particles yielded tau_tau (3 prong) = 288.6 +/- 2.4 (stat) +/- 1.3 (sys) fs. These were combined with previous DELPHI results to measure the tau lifetime, using the full LEP1 data sample, to be tau_tau = 290.9 +/- 1.4 (stat) +/- 1.0 (sys) fs.

  2. Positron lifetime experiments in indium selenide

    International Nuclear Information System (INIS)

    Cruz, R.M. de la; Pareja, R.

    1988-01-01

    Positron lifetime experiments have been performed on as-grown samples which had been isochronally annealed up to 820 K and plastically deformed and these experiments yield a constant lifetime of 282 ± 2 ps which is attributed to bulk positron states in InSe. Electron-irradiated samples exhibit a two-component spectrum, revealing the presence of positron traps which anneal out at about 330 K. The nature of the native shallow donors in InSe is discussed in the light of the results, which support the idea that native donor centres are probably interstitial In atoms rather than Se vacancies. Positron trapping observed in the electron-irradiated samples is attributed to defects related to In vacancies. (author)

  3. A bimodal flexible distribution for lifetime data

    OpenAIRE

    Ramires, Thiago G.; Ortega, Edwin M. M.; Cordeiro, Gauss M.; Hens, Niel

    2016-01-01

    A four-parameter extended bimodal lifetime model called the exponentiated log-sinh Cauchy distribution is proposed. It extends the log-sinh Cauchy and folded Cauchy distributions. We derive some of its mathematical properties including explicit expressions for the ordinary moments and generating and quantile functions. The method of maximum likelihood is used to estimate the model parameters. We implement the fit of the model in the GAMLSS package and provide the codes. The flexibility of the...

  4. Lifetime monogamy and the evolution of eusociality

    DEFF Research Database (Denmark)

    Boomsma, Jacobus J

    2009-01-01

    and termites is thus analogous to the evolution of multicellularity. Focusing on lifetime monogamy as a universal precondition for the evolution of obligate eusociality simplifies the theory and may help to resolve controversies about levels of selection and targets of adaptation. The monogamy window...... underlines that cooperative breeding and eusociality are different domains of social evolution, characterized by different sectors of parameter space for Hamilton's rule....

  5. Lifetime Modeling of Thermal Barrier Coatings

    OpenAIRE

    Hille, T.S.

    2009-01-01

    Thermal barrier coatings (TBCs) are applied in gas turbines to enhance their thermal efficiency by isolating the metallic components from the aggressive hot gas. TBC lifetime is limited by damage processes originating at internal interfaces, which may ultimately lead to delamination and spallation. In the present thesis constitutive models are presented for the coating components and the most detrimental failure mechanisms. To simulate the thermomechanical failure response, the numerical mode...

  6. Fatigue lifetime estimation of railway axles

    Czech Academy of Sciences Publication Activity Database

    Náhlík, Luboš; Pokorný, Pavel; Ševčík, Martin; Fajkoš, R.; Matušek, P.; Hutař, Pavel

    2017-01-01

    Roč. 73, MAR (2017), s. 139-157 ISSN 1350-6307 R&D Projects: GA MŠk LM2015069; GA MŠk(CZ) ED1.1.00/02.0068 Institutional support: RVO:68081723 Keywords : Residual fatigue lifetime * Railway axle * Variable amplitude loading * Fatigue crack propagation * Damage tolerance methodology Subject RIV: JL - Materials Fatigue, Friction Mechanics OBOR OECD: Audio engineering , reliability analysis Impact factor: 1.676, year: 2016

  7. The programs for lifetime extension by AREVA

    International Nuclear Information System (INIS)

    Knoche, P.

    2014-01-01

    In 2011 AREVA launched 2 worldwide programs to meet the demands of its customers: 'AREVA Safety Alliance' that proposes a set of measures for post-Fukushima safety upgrading and 'AREVA Forward Alliance' that is dedicated to lifetime extension projects. Concerning 'AREVA Safety Alliance' about 150 projects have been carried out for 53 customers in 19 countries, as for 'AREVA Forward Alliance' 60% of the lifetime extension projects in the US have been performed by AREVA. In the framework of lifetime extension projects, upgrading measures and services are proposed such as the installation of hydrogen recombiner units, of filtered ventilation systems for severe accidents, or the upgrading of the reactor control system through the implementation of the digital Teleperm XS technology, or recommendations about the methodology to follow for the repair or replacement of important components. The replacement of steam generators and of the pressurizer and with other upgrading works led to a gain of 18.5% on the output power of the Ringhals-4 unit. (A.C.)

  8. Lifetime and performance of NSLS storage rings

    International Nuclear Information System (INIS)

    Halama, H.J.

    1988-01-01

    The performance of synchrotron light sources is measured primarily in terms of beam lifetime, beam size, and the recovery of normal operation after a section of the machine has been brought to atmospheric pressure. The beam lifetime and the beam size depend on the following phenomena: Beam gas interaction which can be either elastic or inelastic scattering on residual gas nuclei or electrons. With the exception of low energy machines, this phenomenon represents the main limiting factor on lifetime; Beam interaction with trapped ions causing both beam loss and defocussing. Residual gas molecules are ionized both by circulating beam and synchrotron radiation. The cross sections for both processes are comparable. The effects of this phenomenon are most troublesome at low energies. The problem can be eliminated by switching to positron beams. Installing clearing electrodes has also been successful; Intrabeam scattering (Touschek effect) is caused by Coulomb scattering among electrons of the same bunch as they execute betatron oscillations. The Touschek effect is strongly dependent on energy and in general is a problem only in low energy machines; and Various instabilities causing both slow and fast beam decay which have been observed in both NSLS rings. A special case due to dust particles that fall into the electron beam is commonly observed in early stages of conditioning. Coherent collective instabilities will not be discussed in this paper. 19 refs., 4 figs., 1 tab

  9. Lifetime and performance of NSLS storage rings

    Energy Technology Data Exchange (ETDEWEB)

    Halama, H.J.

    1988-01-01

    The performance of synchrotron light sources is measured primarily in terms of beam lifetime, beam size, and the recovery of normal operation after a section of the machine has been brought to atmospheric pressure. The beam lifetime and the beam size depend on the following phenomena: Beam gas interaction which can be either elastic or inelastic scattering on residual gas nuclei or electrons. With the exception of low energy machines, this phenomenon represents the main limiting factor on lifetime; Beam interaction with trapped ions causing both beam loss and defocussing. Residual gas molecules are ionized both by circulating beam and synchrotron radiation. The cross sections for both processes are comparable. The effects of this phenomenon are most troublesome at low energies. The problem can be eliminated by switching to positron beams. Installing clearing electrodes has also been successful; Intrabeam scattering (Touschek effect) is caused by Coulomb scattering among electrons of the same bunch as they execute betatron oscillations. The Touschek effect is strongly dependent on energy and in general is a problem only in low energy machines; and Various instabilities causing both slow and fast beam decay which have been observed in both NSLS rings. A special case due to dust particles that fall into the electron beam is commonly observed in early stages of conditioning. Coherent collective instabilities will not be discussed in this paper. 19 refs., 4 figs., 1 tab.

  10. Systematics of spontaneous positron lines

    International Nuclear Information System (INIS)

    Mueller, U.; Reus, T. de; Reinhardt, J.; Mueller, B.; Greiner, W.

    1985-08-01

    Dynamical and spontaneous positron emission are investigated for heavy-ion collisions with long time delay using a semiclassical description. Numerical results and analytical expressions for the characteristic quantities of the resulting spontaneous positron line, i.e., its position, width, and cross section, are compared. The expected behaviour of the line position and cross section and its visibility against the spectrum of dynamically created positrons is discussed in dependence of the united charge Zsub(u) of projectile and target nucleus in a range of systems from Zsub(u)=180 up to Zsub(u)=188. The results are confronted with presently available experimental data, and possible implications on further experiments are worked out. (orig.)

  11. Spontaneous Rotational Inversion in Phycomyces

    KAUST Repository

    Goriely, Alain

    2011-03-01

    The filamentary fungus Phycomyces blakesleeanus undergoes a series of remarkable transitions during aerial growth. During what is known as the stagea IV growth phase, the fungus extends while rotating in a counterclockwise manner when viewed from above (stagea IVa) and then, while continuing to grow, spontaneously reverses to a clockwise rotation (stagea IVb). This phase lasts for 24-48Ah and is sometimes followed by yet another reversal (stageAIVc) before the overall growth ends. Here, we propose a continuum mechanical model of this entire process using nonlinear, anisotropic, elasticity and show how helical anisotropy associated with the cell wall structure can induce spontaneous rotation and, under appropriate circumstances, the observed reversal of rotational handedness. © 2011 American Physical Society.

  12. Spontaneous regression of colon cancer.

    Science.gov (United States)

    Kihara, Kyoichi; Fujita, Shin; Ohshiro, Taihei; Yamamoto, Seiichiro; Sekine, Shigeki

    2015-01-01

    A case of spontaneous regression of transverse colon cancer is reported. A 64-year-old man was diagnosed as having cancer of the transverse colon at a local hospital. Initial and second colonoscopy examinations revealed a typical cancer of the transverse colon, which was diagnosed as moderately differentiated adenocarcinoma. The patient underwent right hemicolectomy 6 weeks after the initial colonoscopy. The resected specimen showed only a scar at the tumor site, and no cancerous tissue was proven histologically. The patient is alive with no evidence of recurrence 1 year after surgery. Although an antitumor immune response is the most likely explanation, the exact nature of the phenomenon was unclear. We describe this rare case and review the literature pertaining to spontaneous regression of colorectal cancer. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Management of intractable spontaneous epistaxis

    Science.gov (United States)

    Rudmik, Luke

    2012-01-01

    Background: Epistaxis is a common otolaryngology emergency and is often controlled with first-line interventions such as cautery, hemostatic agents, or anterior nasal packing. A subset of patients will continue to bleed and require more aggressive therapy. Methods: Intractable spontaneous epistaxis was traditionally managed with posterior nasal packing and prolonged hospital admission. In an effort to reduce patient morbidity and shorten hospital stay, surgical and endovascular techniques have gained popularity. A literature review was conducted. Results: Transnasal endoscopic sphenopalatine artery ligation and arterial embolization provide excellent control rates but the decision to choose one over the other can be challenging. The role of transnasal endoscopic anterior ethmoid artery ligation is unclear but may be considered in certain cases when bleeding localizes to the ethmoid region. Conclusion: This article will focus on the management of intractable spontaneous epistaxis and discuss the role of endoscopic arterial ligation and embolization as it pertains to this challenging clinical scenario. PMID:22391084

  14. Spontaneous baryogenesis in warm inflation

    OpenAIRE

    Brandenberger, Robert H.; Yamaguchi, Masahide

    2003-01-01

    We discuss spontaneous baryogenesis in the warm inflation scenario. In contrast with standard inflation models, radiation always exists in the warm inflation scenario, and the inflaton must be directly coupled to it. Also, the transition to the post-inflationary radiation dominated phase is smooth and the entropy is not significantly increased at the end of the period of inflation. In addition, after the period of warm inflation ends, the inflaton does not oscillate coherently but slowly roll...

  15. Spontaneous Splenic Rupture in Melanoma

    Directory of Open Access Journals (Sweden)

    Hadi Mirfazaelian

    2014-01-01

    Full Text Available Spontaneous rupture of spleen due to malignant melanoma is a rare situation, with only a few case reports in the literature. This study reports a previously healthy, 30-year-old man who came with chief complaint of acute abdominal pain to emergency room. On physical examination, abdominal tenderness and guarding were detected to be coincident with hypotension. Ultrasonography revealed mild splenomegaly with moderate free fluid in abdominopelvic cavity. Considering acute abdominal pain and hemodynamic instability, he underwent splenectomy with splenic rupture as the source of bleeding. Histologic examination showed diffuse infiltration by tumor. Immunohistochemical study (positive for S100, HMB45, and vimentin and negative for CK, CD10, CK20, CK7, CD30, LCA, EMA, and chromogranin confirmed metastatic malignant melanoma. On further questioning, there was a past history of a nasal dark skin lesion which was removed two years ago with no pathologic examination. Spontaneous (nontraumatic rupture of spleen is an uncommon situation and it happens very rarely due to neoplastic metastasis. Metastasis of malignant melanoma is one of the rare causes of the spontaneous rupture of spleen.

  16. Solid-State Camera System for Fluorescence Lifetime Microscopy

    NARCIS (Netherlands)

    Zhao, Q.

    2014-01-01

    Fluorescence microscopy is a well-established platform for biology and biomedical research (Chapter 2). Based on this platform, fluorescence lifetime imaging microscopy (FLIM) has been developed to measure fluorescence lifetimes, which are independent of fluorophore concentration and excitation

  17. Lifetimes of Machinery and Equipment. Evidence from Dutch Manufacturing

    NARCIS (Netherlands)

    Erumban, Abdul Azeez

    2006-01-01

    This paper estimates service lifetimes for capital assets in Dutch manufacturing industries, using information on asset retirement patterns. A Weibull distribution function is estimated using a nonlinear regression technique to derive service lifetimes for three selected asset types: transport

  18. Measurement of the τ-lepton lifetime at Belle

    Energy Technology Data Exchange (ETDEWEB)

    Belous, K.; Shapkin, M.; Sokolov, A.; Adachi, I.; Aihara, H.; Asner, David M.; Aulchenko, V.; Bakich, A. M.; Bala, Anu; Bhuyan, Bipul; Bobrov, A.; Bondar, A.; Bonvicini, Giovanni; Bozek, A.; Bracko, Marko; Browder, Thomas E.; Cervenkov, D.; Chekelian, V.; Chen, A.; Cheon, B. G.; Chilikin, K.; Chistov, R.; Cho, K.; Chobanova, V.; Choi, Y.; Cinabro, David A.; Dalseno, J.; Dolezal, Z.; Dutta, Deepanwita; Eidelman, S.; Epifanov, D.; Farhat, H.; Fast, James E.; Ferber, T.; Gaur, Vipin; Ganguly, Sudeshna; Garmash, A.; Gillard, R.; Goh, Y. M.; Golob, B.; Haba, J.; Hara, Takanori; Hayasaka, K.; Hayashii, H.; Hoshi, Y.; Hou, W. S.; Iijima, T.; Inami, K.; Ishikawa, A.; Itoh, R.; Iwashita, T.; Jaegle, Igal; Julius, T.; Kato, E.; Kichimi, H.; Kiesling, C.; Kim, D. Y.; Kim, H. J.; Kim, J. B.; Kim, M. J.; Kim, Y. J.; Kinoshita, Kay; Ko, Byeong Rok; Kodys, P.; Korpar, S.; Krizan, Jean; Krokovny, Pavel; Kuhr, T.; Kuzmin, A.; Kwon, Y. J.; Lange, J. S.; Lee, S. H.; Libby, J.; Liventsev, Dmitri; Lukin, P.; Matvienko, D.; Miyata, H.; Mizuk, R.; Mohanty, G. B.; Mori, T.; Mussa, R.; Nagasaka, Y.; Nakano, E.; Nakao, M.; Nayak, Minakshi; Nedelkovska, E.; Ng, C.; Nisar, N. K.; Nishida, S.; Nitoh, O.; Ogawa, S.; Okuno, S.; Olsen, Stephen L.; Ostrowicz, W.; Pakhlova, Galina; Park, C. W.; Park, H.; Park, H. K.; Pedlar, Todd; Pestotnik, Rok; Petric, Marko; Piilonen, Leo E.; Ritter, M.; Rohrken, M.; Rostomyan, A.; Ryu, S.; Sahoo, Himansu B.; Saito, Tomoyuki; Sakai, Yoshihide; Sandilya, Saurabh; Santel, Daniel; Santelj, Luka; Sanuki, T.; Savinov, Vladimir; Schneider, O.; Schnell, G.; Schwanda, C.; Semmler, D.; Senyo, K.; Seon, O.; Shebalin, V.; Shen, C. P.; Shibata, T. A.; Shiu, Jing-Ge; Shwartz, B.; Sibidanov, A.; Simon, F.; Sohn, Young-Soo; Stanic, S.; Stanic, M.; Steder, M.; Sumiyoshi, T.; Tamponi, Umberto; Tatishvili, Gocha; Teramoto, Y.; Trabelsi, K.; Tsuboyama, T.; Uchida, M.; Uehara, S.; Uglov, T.; Unno, Yuji; Uno, S.; Usov, Y.; Vahsen, Sven E.; Van Hulse, C.; Vanhoefer, P.; Varner, Gary; Varvell, K. E.; Vinokurova, A.; Vorobyev, V.; Wagner, M. N.; Wang, C. H.; Wang, P.; Watanabe, M.; Watanabe, Y.; Williams, K. M.; Won, E.; Yamaoka, J.; Yamashita, Y.; Yashchenko, S.; Yook, Youngmin; Yuan, C. Z.; Zhang, Z. P.; Zhilich, V.; Zupanc, A.

    2014-01-23

    The lifetime of the Tau-lepton is measured using the process , where both leptons decay to . The result for the mean lifetime, based on of data collected with the Belle detector at the resonance and below, is . The first measurement of the lifetime difference between and is performed. The upper limit on the relative lifetime difference between positive and negative leptons is at 90% C.L. (That would make sense if ERICA could take RTF....)

  19. Radiation lifetimes and failure mechanisms of carbon stripper foils

    International Nuclear Information System (INIS)

    Auble, R.L.

    1981-01-01

    Measurements of lifetimes of thin carbon foils under heavy-ion irradiation are compiled and recent advances in stripper foil technology are reviewed. The impact of recent foil lifetime improvements, many by more than an order of magnitude, on heavy-ion electrostatic accelerators is discussed. Foil inhomogeneities, particularly those caused by sputtering are suggested to be a prime factor in usable foil lifetimes

  20. Optimizing design of converters using power cycling lifetime models

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Ørndrup; Munk-Nielsen, Stig

    2015-01-01

    Converter power cycling lifetime depends heavily on converter operation point. A lifetime model of a single power module switched mode power supply with wide input voltage range is shown. A lifetime model is created using a power loss model, a thermal model and a model for power cycling capability...

  1. Spontaneous low frequency oscillation studies in gallium arsenide fast photoconductors

    CERN Document Server

    Foulon, F; Brullot, B; Petit, P; Bergonzo, P; Rubbelynck, C

    1999-01-01

    We have investigated the influence of spontaneous low frequency oscillations (LFO, f approx 0.01 Hz) occurring at high electric field (>1 kV/cm) in resistive photoconductors (PCD) made from semi-insulating GaAs on the response of the PCDs under pulsed gamma-ray irradiation (E approx 1.2 MeV, tau sub F sub W sub H sub M =30 ns). The PCDs were fabricated using GaAs from five commercially available sources. The PCDs were irradiated with fission neutrons in order to reduce their response time down to less than 100 ps. The amplitude of the LFOs was found to be related to the carrier lifetime, and thus defect concentration in the GaAs material. It was larger for material exhibiting high carrier lifetime. Increasing the localised defect concentration, such as EL2 type defect, through GaAs irradiation with fission neutrons was found to decrease the amplitude of the LFOs. PCDs irradiated at high neutron doses (>1x10 sup 1 sup 5 neutrons/cm sup 2) showed no LFOs. It is suggested that interactions between the propagatin...

  2. Lifetime Effects of Small Unruptured Intracranial Aneurysms.

    Science.gov (United States)

    Aishima, Kaoru; Shimizu, Tatsuya; Aihara, Masanori; Yoshimoto, Yuhei

    2016-11-01

    Recent prospective multicenter studies have shown that the probability of rupture of unruptured aneurysms with maximal diameter <7 mm is rather low. However, the overall risks and long-term impact of unruptured aneurysms on lifetime quality of life are still unknown. A mathematical model of the natural history of intracranial aneurysms was constructed, in which the hypothetical individuals with or without unruptured aneurysm transit between discrete health states. The annual rupture rate of small aneurysms was assumed to be 0.5% in the baseline analysis, followed by the subsequent sensitivity analysis. The analyses were continued until cumulative death rate from subarachnoid hemorrhage or other causes reached 1.0. Age-specific ratios of death of subarachnoid hemorrhage in the individuals harboring unruptured aneurysm, if dying at 60 years old, were 25% in men and 43% in women. These ratios decreased rapidly with higher age. Most (more than 90%) patients with small aneurysms were expected to die of diseases other than subarachnoid hemorrhage. In the baseline analysis (60-year-old individuals), lifetime lost to small aneurysms could be estimated as 3.8% for men and 4.2% for women, but a somewhat larger impact could be identified in the young and/or female individuals compared with in the elderly and/or male individuals. Lifetime effects of small unruptured aneurysms without risk factors increasing the probability of rupture are relatively small, and most patients were expected to die of diseases other than subarachnoid hemorrhage. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Microscopic theory of semiconductor light emission

    Science.gov (United States)

    Kira, M.; Jahnke, Frank; Hoyer, W.; Koch, Stephan W.

    2000-07-01

    A fully quantum mechanical theory for a system of photons and Coulomb interacting electron-hole pairs in semiconductors is investigated. The resulting semiconductor luminescence equations are discussed and evaluated for a variety of examples. For a quantum-well system, it is shown how luminescence at the exciton resonance can result from an incoherent electron-hole plasma. Also changes in carrier lifetimes due to radiative recombination are studied.

  4. Multiphoton fluorescence lifetime imaging of human hair.

    Science.gov (United States)

    Ehlers, Alexander; Riemann, Iris; Stark, Martin; König, Karsten

    2007-02-01

    In vivo and in vitro multiphoton imaging was used to perform high resolution optical sectioning of human hair by nonlinear excitation of endogenous as well as exogenous fluorophores. Multiphoton fluorescence lifetime imaging (FLIM) based on time-resolved single photon counting and near-infrared femtosecond laser pulse excitation was employed to analyze the various fluorescent hair components. Time-resolved multiphoton imaging of intratissue pigments has the potential (i) to identify endogenous keratin and melanin, (ii) to obtain information on intrahair dye accumulation, (iii) to study bleaching effects, and (iv) to monitor the intratissue diffusion of pharmaceutical and cosmetical components along hair shafts.

  5. Final report on reliability and lifetime prediction.

    Energy Technology Data Exchange (ETDEWEB)

    Gillen, Kenneth T; Wise, Jonathan; Jones, Gary D.; Causa, Al G.; Terrill, Edward R.; Borowczak, Marc

    2012-12-01

    This document highlights the important results obtained from the subtask of the Goodyear CRADA devoted to better understanding reliability of tires and to developing better lifetime prediction methods. The overall objective was to establish the chemical and physical basis for the degradation of tires using standard as well as unique models and experimental techniques. Of particular interest was the potential application of our unique modulus profiling apparatus for assessing tire properties and for following tire degradation. During the course of this complex investigation, extensive relevant information was generated, including experimental results, data analyses and development of models and instruments. Detailed descriptions of the findings are included in this report.

  6. Evidence for contemporary evolution during Darwin's lifetime.

    Science.gov (United States)

    Hart, Adam G; Stafford, Richard; Smith, Angela L; Goodenough, Anne E

    2010-02-09

    Darwin's On the Origin of Species[1] introduced the world to the most fundamental concept in biological sciences - evolution. However, in the 150 years following publication of his seminal work, much has been made of the fact that Darwin was missing at least one crucial link in his chain of evidence - he had no evidence for contemporary evolution through natural selection. Indeed, as one commentator noted on the centenary of the publication of Origin, "Had Darwin observed industrial melanism he would have seen evolution occurring not in thousands of years but in thousands of days - well within his lifetime. He would have witnessed the consummation and confirmation of his life's work"[2].

  7. ''LIFETIME'': a computer program for analyzing Doppler-shift recoil-distance nuclear lifetime data

    International Nuclear Information System (INIS)

    Wells, J.C.; Fewell, M.P.; Johnson, N.R.

    1985-10-01

    The program LIFETIME is designed to extract lifetimes of nuclear levels from Doppler-shift recoil-distance experiments by performing a least-square fit to the experimental data (shifted and unshifted photopeak intensities and branching ratios). Initial populations of levels and transition rates between levels are treated as variable parameters. In terms of these parameters the population of each level as a function of time is determined by the Bateman equations, and the shifted and unshifted intensities are calculated. 19 refs., 5 figs

  8. Measurement of Beam Lifetime and Applications for SPEAR3

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiaobiao; Corbett, Jeff; /SLAC

    2011-04-05

    Beam lifetime studies for the SPEAR3 storage ring are presented. The three lifetime components are separated with lifetime measurements under various combinations of beam currents and fill patterns and vertical scraper scans. Touschek lifetime is studied with rf voltage scans and with the horizontal or vertical scrapers inserted. The measurements are explained with calculations based on the calibrated lattice model. Quantum lifetime measurements are performed with reduced longitudinal and horizontal apertures, respectively, from which we deduce the radiation energy loss down to a few keV per revolution and the horizontal beam size.

  9. Spontaneous oscillations in microfluidic networks

    Science.gov (United States)

    Case, Daniel; Angilella, Jean-Regis; Motter, Adilson

    2017-11-01

    Precisely controlling flows within microfluidic systems is often difficult which typically results in systems being heavily reliant on numerous external pumps and computers. Here, I present a simple microfluidic network that exhibits flow rate switching, bistablity, and spontaneous oscillations controlled by a single pressure. That is, by solely changing the driving pressure, it is possible to switch between an oscillating and steady flow state. Such functionality does not rely on external hardware and may even serve as an on-chip memory or timing mechanism. I use an analytic model and rigorous fluid dynamics simulations to show these results.

  10. General features of spontaneous baryogenesis

    Science.gov (United States)

    Arbuzova, Elena

    2017-04-01

    The classical version of spontaneous baryogenesis is studied in details. It is shown that the relation between the time derivative of the (pseudo)goldstone field and the baryonic chemical potential essentially depends upon the representation chosen for the fermionic fields with non-zero baryonic number (quarks). The kinetic equation, used for the calculations of the cosmological baryon asymmetry, is generalized to the case of non-stationary background. The effects of the finite interval of the integration over time are also included into consideration.

  11. Spontaneous osteonecrosis of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Kattapuram, Taj M. [Department of Radiology, Massachusetts General Hospital (United States); Kattapuram, Susan V. [Department of Radiology, Massachusetts General Hospital (United States)], E-mail: skattapuram@partners.org

    2008-07-15

    Spontaneous osteonecrosis of the knee presents with acute onset of severe, pain in elderly patients, usually female and usually without a history of trauma. Originally described as idiopathic osteonecrosis, the exact etiology is still debated. Evidence suggests that an acute fracture occurs as a result of chronic stress or minor trauma to a weakened subchondral bone plate. The imaging characteristics on MR reflect the age of the lesion and the symptoms. More appropriate terminology may be ' subchondral insufficiency fracture of the knee' or 'focal subchondral osteonecrosis'.

  12. Enhancement of spontaneous emission rate and reduction in amplified spontaneous emission threshold in electrodeposited three-dimensional ZnO photonic crystal

    Science.gov (United States)

    Zhong, Yongchun; Yue, Zhounan; Wong, George K. L.; Xi, Yan Yan; Hsu, Yuk Fan; Djurišić, Aleksandra B.; Dong, Jian-Wen; Chen, Wen-Jie; Wong, Kam Sing

    2010-11-01

    ZnO photonic crystal (PC) with face-center-cube type structure is fabricated by electrodeposition using holographic lithographically made organic (SU-8) template. Photonic band gap effect (reflection peak and transmission dip in infrared spectral region) is clearly seen. Observation of strong enhancement and blueshift of the emission peak (from 383.8 to 378.8 nm), shortening of the exciton photoluminescence lifetime (from 88 to 34 ps), and reduction in amplified spontaneous emission threshold of ZnO PC compared to that of the reference nonstructured electrodeposited ZnO showed clear evidence of PC structure affecting the ZnO exciton emission.

  13. A Satellite Mortality Study to Support Space Systems Lifetime Prediction

    Science.gov (United States)

    Fox, George; Salazar, Ronald; Habib-Agahi, Hamid; Dubos, Gregory

    2013-01-01

    Estimating the operational lifetime of satellites and spacecraft is a complex process. Operational lifetime can differ from mission design lifetime for a variety of reasons. Unexpected mortality can occur due to human errors in design and fabrication, to human errors in launch and operations, to random anomalies of hardware and software or even satellite function degradation or technology change, leading to unrealized economic or mission return. This study focuses on data collection of public information using, for the first time, a large, publically available dataset, and preliminary analysis of satellite lifetimes, both operational lifetime and design lifetime. The objective of this study is the illustration of the relationship of design life to actual lifetime for some representative classes of satellites and spacecraft. First, a Weibull and Exponential lifetime analysis comparison is performed on the ratio of mission operating lifetime to design life, accounting for terminated and ongoing missions. Next a Kaplan-Meier survivor function, standard practice for clinical trials analysis, is estimated from operating lifetime. Bootstrap resampling is used to provide uncertainty estimates of selected survival probabilities. This study highlights the need for more detailed databases and engineering reliability models of satellite lifetime that include satellite systems and subsystems, operations procedures and environmental characteristics to support the design of complex, multi-generation, long-lived space systems in Earth orbit.

  14. Heuristic Modeling for TRMM Lifetime Predictions

    Science.gov (United States)

    Jordan, P. S.; Sharer, P. J.; DeFazio, R. L.

    1996-01-01

    Analysis time for computing the expected mission lifetimes of proposed frequently maneuvering, tightly altitude constrained, Earth orbiting spacecraft have been significantly reduced by means of a heuristic modeling method implemented in a commercial-off-the-shelf spreadsheet product (QuattroPro) running on a personal computer (PC). The method uses a look-up table to estimate the maneuver frequency per month as a function of the spacecraft ballistic coefficient and the solar flux index, then computes the associated fuel use by a simple engine model. Maneuver frequency data points are produced by means of a single 1-month run of traditional mission analysis software for each of the 12 to 25 data points required for the table. As the data point computations are required only a mission design start-up and on the occasion of significant mission redesigns, the dependence on time consuming traditional modeling methods is dramatically reduced. Results to date have agreed with traditional methods to within 1 to 1.5 percent. The spreadsheet approach is applicable to a wide variety of Earth orbiting spacecraft with tight altitude constraints. It will be particularly useful to such missions as the Tropical Rainfall Measurement Mission scheduled for launch in 1997, whose mission lifetime calculations are heavily dependent on frequently revised solar flux predictions.

  15. Digital positron lifetime: the influence of noise

    International Nuclear Information System (INIS)

    Krille, Arnold; Krause-Rehberg, Reinhard; Anwand, Wolfgang

    2011-01-01

    In contrast to the world around where everything seems to go digital as soon as possible, positron lifetime spectrometers are kind of a 'last sanctuary' for analog measurements. Only a few of the newer spectrometers use the analog-digital-converters directly after the photomultipliers and extract the timing information via computer. Judging from their results it seems as if the current available converters and the timing mathematics are only as good as the conventional analog setup in the timing resolution. As it is decided that EPOS [1] will use digital positron lifetime, we try to find some reasons for limited timing resolution by simulating anode pulses from the photomultipliers and measuring the FWHM. We create pulses similar to current state-of-the-art 4GS/s digitizers but can control the level of noise and the bit-depth independently. We found that especially the noise (that would come from the analog electronics in/before the converters) has a great influence on the timing resolution. Also we try to use lowpass filtering to reduce that influence with great success.

  16. First positron annihilation lifetime measurement of Pu

    International Nuclear Information System (INIS)

    Colmenares, C.; Howell, R.H.; Ancheta, D.; Cowan, T.; Hanafee, J.; Sterne, P.

    1996-01-01

    We have made the first measurement of defects in an aged sample of δ phase, Ga stabilized Pu, using positron annihilation lifetime spectroscopy. This measurement validates the procedure necessary to perform measurements on this highly toxic material and obtain data representative of sample conditions. Comparison of the positron annihilation lifetime analysis of the data with calculated values suggests that He filled vacancies or vacancy clusters dominate the defect population. Such defects are the necessary precursor to void growth and swelling. The evolution of defects resulting from the radioactive decay of Pu during its life in the stockpile is one of the unknown quantities affecting our confidence in predictions of the limit on stockpile components. Radiation damage leads to changes in the size and strength of metals studied for reactor and accelerator use and similar effects may be expected in Pu. The evolution of radiation produced vacancies into larger void structures and accompanying macroscopic swelling may occur in Pu at some age. A detailed understanding of the defects in self irradiated Pu is required to predict the time scale of void swelling and related radiation effects. 1 fig

  17. New detectors to explore the lifetime frontier

    Science.gov (United States)

    Chou, John Paul; Curtin, David; Lubatti, H. J.

    2017-04-01

    Long-lived particles (LLPs) are a common feature in many beyond the Standard Model theories, including supersymmetry, and are generically produced in exotic Higgs decays. Unfortunately, no existing or proposed search strategy will be able to observe the decay of non-hadronic electrically neutral LLPs with masses above ∼ GeV and lifetimes near the limit set by Big Bang Nucleosynthesis (BBN), cτ ≲107-108 m. We propose the MATHUSLA surface detector concept (MAssive Timing Hodoscope for Ultra Stable neutraL pArticles), which can be implemented with existing technology and in time for the high luminosity LHC upgrade to find such ultra-long-lived particles (ULLPs), whether produced in exotic Higgs decays or more general production modes. We also advocate a dedicated LLP detector at a future 100 TeV collider, where a modestly sized underground design can discover ULLPs with lifetimes at the BBN limit produced in sub-percent level exotic Higgs decays.

  18. Radiological evaluation of spontaneous pneumoperitoneum

    International Nuclear Information System (INIS)

    Kim, H. S.; Kim, J. D.; Rhee, H. S.

    1982-01-01

    112 cases of spontaneous penumoperitoneum, the causes of which were confirmed by clinical and surgical procedure at Presbyterian Medical Center from January, 1977 to July, 1981 were reviewed radiologically. The results were as follows: 1. Perforation of duodenal ulcer (46/112: 41.1%), stomach ulcer (22/112: 19.6%), and stomach cancer (11/112: 9.8%) were the three most common causes of spontaneous penumoperitoneum. These were 70.5% of all causes. 2. The most common site of free gas was both subdiaphragmatic areas (46: 41.1%). Others were Rt. subdiaphragmatic only (31: 27.7%), both subdiaphragmatic with subhepatic (16: 14.3%), Rt. subdiaphragmatic with subhepatic (7: 6.2%), Rt. subdiaphragmatic only (5: 4.4%), diffuse in abdomen (4: 3.6%), and subhepatic only (3: 2.7%). So 92.0% (103/112) were located in RUQ. 3. The radiological shape of free gas was classified: crescent (52: 46.4%) of small amount; half-moon (21: 18.8%) of moderate amount; large or diffuse (39: 34.8%) of large amount.4. The age between 31 and 60 occupied 69.1% (77/112), and male was predominant (5.2 times). 5. The patient's position showing free air most frequently was erect

  19. A Case of Multiple Spontaneous Keloid Scars

    Directory of Open Access Journals (Sweden)

    Abdulhadi Jfri

    2015-07-01

    Full Text Available Keloid scars result from an abnormal healing response to cutaneous injury or inflammation that extends beyond the borders of the original wound. Spontaneous keloid scars forming in the absence of any previous trauma or surgical procedure are rare. Certain syndromes have been associated with this phenomenon, and few reports have discussed the evidence of single spontaneous keloid scar, which raises the question whether they are really spontaneous. Here, we present a 27-year-old mentally retarded single female with orbital hypertelorism, broad nasal bridge, repaired cleft lip and high-arched palate who presented with progressive multiple spontaneous keloid scars in different parts of her body which were confirmed histologically by the presence of typical keloidal collagen. This report supports the fact that keloid scars can appear spontaneously and are possibly linked to a genetic factor. Furthermore, it describes a new presentation of spontaneous keloid scars in the form of multiple large lesions in different sites of the body.

  20. Spontaneity of communication in individuals with autism.

    Science.gov (United States)

    Chiang, Hsu-Min; Carter, Mark

    2008-04-01

    This article provides an examination of issues related to spontaneity of communication in children with autism. Deficits relating to spontaneity or initiation are frequently reported in individuals with autism, particularly in relation to communication and social behavior. Nevertheless, spontaneity is not necessarily clearly conceptualized or measured. Several approaches to conceptualization of communicative spontaneity are examined with a particular focus on the continuum model and how it might be practically applied. A range of possible explanations for deficits in spontaneity of communication in children with autism is subsequently explored, including external factors (highly structured teaching programs, failure to systematically instruct for spontaneity) and intrinsic characteristics (intellectual disability, stimulus overselectivity, weak central coherence). Possible implications for future research are presented.

  1. Lifetime-management and lifetime-extension at PAKS nuclear power plant

    International Nuclear Information System (INIS)

    Katona, Tamas; Ratkai, Sandor; Janosi, Agnes Biro

    2002-01-01

    Paks Nuclear Power Plant provides 38-40% of domestic generation at lowest price. It has an important energy-policy role in Hungary. NPP Paks shall be a decisive and perspectively permanent element of the domestic electricity generation during the next two decades, which shall be ensured by plant safe operation, the lifetime extension and power uprating. Paks Nuclear Power Plant investigated the nuclear power plant's lifetime extension possibilities and alternatives, as well as technical and business feasibility of such alternatives. The feasibility study is based on the evaluation of a representative set of systems, structures and components, operational, test, in-service inspection and maintenance practice, experience and findings of the Periodic Safety Review. The most important results of this study showing the feasibility of 20 years lifetime extension is summarised in the paper. It was found that there are no technical or safety issues or limits, which may inhibit the operation of the Nuclear Power Plant Paks up to 50 years. In case of most systems and equipment the recent monitoring, maintenance and regular reconstruction practice of the NPP Paks allows the lifetime extension without outstanding cost. Replacement or reconstruction of a few equipment and systems requires significant investment costs. Material of reactor vessels of VVER/213 incorporated at Paks, compared to vessels of the similar units, is less sensitive to the embrittlement. At units 3-4 reactor vessels do not require any measure, consequently, any additional cost, even in case of a lifetime of 50 years. At unit 2 to extend the lifetime of the reactor vessel, only heating-up of emergency core cooling tanks is needed in order to decrease thermal stress levels caused by pressure thermal shock (PST) transients. For this purpose cost-effective technical solutions are available. At unit 1, beside the heating-up of the emergency core cooling tanks annealing of the welded joint No. 5/6 close to the

  2. Spontaneous cryptococcal peritonitis in cirrhotic patients.

    Directory of Open Access Journals (Sweden)

    Sungkanuparph S

    2002-07-01

    Full Text Available Spontaneous bacterial peritonitis is a common complication in patients with cirrhosis and ascites. However, spontaneous peritonitis caused by Cryptococcus neoformans is uncommon. Delayed diagnosis of cryptococcal peritonitis often results in death. We describe three cases of spontaneous cryptococcal peritonitis in patients with decompensated cirrhosis. One case had associated symptomatic human immunodeficiency virus infection. Clinical awareness of this entity may lead to the early diagnosis and proper treatment.

  3. Spontaneous Intracranial Hypotension without Orthostatic Headache

    Directory of Open Access Journals (Sweden)

    Tülay Kansu

    2009-03-01

    Full Text Available We report 2 cases of spontaneous intracranial hypotension that presented with unilateral abducens nerve palsy, without orthostatic headache. While sixth nerve palsies improved without any intervention, subdural hematoma was detected with magnetic resonance imaging. We conclude that headache may be absent in spontaneous intracranial hypotension and spontaneous improvement of sixth nerve palsy can occur, even after the development of a subdural hematoma

  4. Spontaneous renal hematoma - a case report

    International Nuclear Information System (INIS)

    Obrzut, M.; Obrzut, M.; Homa, J.; Obrzut, B.

    2006-01-01

    Spontaneous pararenal hematoma is a rare pathology most frequently coexisting with renal tumours, vascular anomalies and inflammatory processes. In some cases one cannot establish its etiology. The paper describes a case of a 58-year-old man with a spontaneous pararenal hematoma and presents a diagnostic algorithm. Ultrasonography and CT play an important role in diagnostics of spontaneous pararenal haemorrhages. These methods enable a precise evaluation of size and location of hematoma and its evolution. (author)

  5. Accelerated lifetime testing methodology for lifetime estimation of Lithium-ion batteries used in augmented wind power plants

    DEFF Research Database (Denmark)

    Stroe, Daniel Ioan; Swierczynski, Maciej Jozef; Stan, Ana-Irina

    2013-01-01

    The development of lifetime estimation models for Lithium-ion battery cells, which are working under highly variable mission profiles characteristic for wind power plant applications, requires a lot of expenditures and time resources. Therefore, batteries have to be tested under accelerated...... lifetime ageing conditions. This paper presents a three-stage methodology used for accelerated lifetime testing of Lithium-ion batteries. The results obtained at the end of the accelerated ageing process can be used for the parametrization of a performance-degradation lifetime model. In the proposed...... methodology both calendar and cycling lifetime tests are considered since both components are influencing the lifetime of Lithium-ion batteries. The methodology proposes also a lifetime model verification stage, where Lithium-ion battery cells are tested at normal operating conditions using an application...

  6. The Production Mechanism Lifetimes of Charmed Particles

    Energy Technology Data Exchange (ETDEWEB)

    Frederiksen, Soren Grandborg [Ottawa U.

    1987-01-01

    The discovery of the $J/\\psi$; in 1974 [1], a resonance consisting of a charmed quarkantiquark pair was a major turning point in elementary particle physics. Predicted ten years earlier [2] to help explain the absence of strangeness changing neutral currents, the charm quark was expected to decay weakly into a strange quark [3]. The charm quark was also very important in the GW (Glashow, Iliopoulos and Maiani) model [4] of weak interactions. The $J/\\psi$; provided indirect evidence for the existence of charm. However, it was not until two years later with the discovery [5] of the D0 that a particle with net charm was observed. A number of experiments subsequently looked for and discovered other charmed particles [6], 7J. The main difficulties in studying charmed particles are their short lifetimes ($\\tau \\approx 10^{-13}$ sec.) and low production rates ($\\sigma(pp \\to c\\bar{c} + X) \\approx$ = 80 $\\pm 60,\\mu b$) [7]. The short lifetimes correspond to very short decay lengths, of the order of a few hundred microns for charmed particles with a few GeV/c momentum. Due to the short decay length, nuclear emulsion with its high spatial resolution is an ideal detector since it is possible to actually see the production and subsequent decay of the charm particle. In 1977 a hybrid emulsion-spectrometer experiment (E-531) was set up in the wide-band neutrino beam at Fermilab. An advantage of the neutrinos is that they do not produce any tracks in the emulsion; therefore the background is very low and it is possible to leave the emulsion target in the beam for several months. Results using data collected from November 1978 to February 1979 (referred to as the first run) have already been published in 'numerous theses [8,9,10,11] and articles [12,13,14,15,16,17]. The exposure time was only about four months while the search for events in the emulsion and their subsequent analysis took several years. This thesis will discuss the data obtained in a second run of

  7. Education and Lifetime Earnings in the United States.

    Science.gov (United States)

    Tamborini, Christopher R; Kim, ChangHwan; Sakamoto, Arthur

    2015-08-01

    Differences in lifetime earnings by educational attainment have been of great research and policy interest. Although a large literature examines earnings differences by educational attainment, research on lifetime earnings--which refers to total accumulated earnings from entry into the labor market until retirement--remains limited because of the paucity of adequate data. Using data that match respondents in the Survey of Income and Program Participation to their longitudinal tax earnings as recorded by the Social Security Administration, we estimate the 50-year work career effects of education on lifetime earnings for men and women. By overcoming the purely synthetic cohort approach, our results provide a more realistic appraisal of actual patterns of lifetime earnings. Detailed estimates are provided for gross lifetime earnings by education; net lifetime earnings after controlling for covariates associated with the probability of obtaining a bachelor's degree; and the net present 50-year lifetime value of education at age 20. In addition, we provide estimates that include individuals with zero earnings and disability. We also assess the adequacy of the purely synthetic cohort approach, which uses age differences in earnings observed in cross-sectional surveys to approximate lifetime earnings. Overall, our results confirm the persistent positive effects of higher education on earnings over different stages of the work career and over a lifetime, but also reveal notably smaller net effects on lifetime earnings compared with previously reported estimates. We discuss the implications of these and other findings.

  8. Lifetime analysis of fusion-reactor components

    International Nuclear Information System (INIS)

    Mattas, R.F.

    1983-01-01

    A one-dimensional computer code has been developed to examine the lifetime of first-wall and impurity-control components. The code incorporates the operating and design parameters, the material characteristics, and the appropriate failure criteria for the individual components. The major emphasis of the modelling effort has been to calculate the temperature-stress-strain-radiation effects history of a component so that the synergystic effects between sputtering erosion, swelling, creep, fatigue, and crack growth can be examined. The general forms of the property equations are the same for all materials in order to provide the greatest flexibility for materials selection in the code. The code is capable of determining the behavior of a plate, composed of either a single or dual material structure, that is either totally constrained or constrained from bending but not from expansion. The code has been utilized to analyze the first walls for FED/INTOR and DEMO

  9. Lifetime management of Magnox power stations

    International Nuclear Information System (INIS)

    Smitton, C.

    1998-01-01

    Magnox Electric, which is, a subsidiary of BNFL, operates six nuclear power plants that have an average age of about 33 years. The procedures developed to maintain the plants and ensure nuclear safety in longer-term operation are reviewed. The technical limit on station lifetimes is expected to be determined by the effect of ageing on major reactor structures where replacement is impractical. Examination of the effect of ageing confirms that the stations are capable of operating to a life of at least 40 years. The economic factors affecting operation are reviewed, recognising the need to sell electricity in a competitive market. Recently Magnox Electric and BNFL have merged and all plant supporting Magnox operations are now within a single integrated company that will provide further opportunities for improved efficiency. (author)

  10. Finite quasiparticle lifetime in disordered superconductors.

    Energy Technology Data Exchange (ETDEWEB)

    Zemlicka, M.; Neilinger, P.; Trgala, M; Rehak, M; Manca, D.; Grajcar, M.; Szabo, P.; Samuely, P.; Gazi, S.; Hubner, U.; Vinokur, V. M.; Il' ichev, E.

    2015-12-08

    We investigate the complex conductivity of a highly disordered MoC superconducting film with k(F)l approximate to 1, where k(F) is the Fermi wave number and l is the mean free path, derived from experimental transmission characteristics of coplanar waveguide resonators in a wide temperature range below the superconducting transition temperature T-c. We find that the original Mattis-Bardeen model with a finite quasiparticle lifetime, tau, offers a perfect description of the experimentally observed complex conductivity. We show that iota is appreciably reduced by scattering effects. Characteristics of the scattering centers are independently found by scanning tunneling spectroscopy and agree with those determined from the complex conductivity.

  11. Spectroscopy of neutron-rich nuclei populated in the spontaneous fission of 252Cf and 248Cm

    International Nuclear Information System (INIS)

    Smith, A. G.; Simpson, G. S.; Billowes, J.; Durell, J. L.; Phillips, W. R.; Dagnall, P. J.; Freeman, S. J.; Leddy, M.; Roach, A. A.; Smith, J. F.

    1999-01-01

    In this paper we present research that has been carried out using the Euroball and Eurogam arrays to detect γ rays emitted from spontaneously fissioning 248 Cm and 252 Cf. The paper focuses on three sub-areas of current activity, namely, the measurement of yields of secondary fragment pairs, the measurement of state lifetimes at around spin 10, and recent measurements of g-factors of excited states in fission fragments. (c) 1999 American Institute of Physics

  12. Biomarkers of spontaneous preterm birth

    DEFF Research Database (Denmark)

    Polettini, Jossimara; Cobo, Teresa; Kacerovsky, Marian

    2017-01-01

    predictors of pregnancy outcome. This systematic review was conducted to synthesize the knowledge on PTB biomarkers identified using multiplex analysis. Three electronic databases (PubMed, EMBASE and Web of Science) were searched for studies in any language reporting the use of multiplex assays for maternal......Despite decades of research on risk indicators of spontaneous preterm birth (PTB), reliable biomarkers are still not available to screen or diagnose high-risk pregnancies. Several biomarkers in maternal and fetal compartments have been mechanistically linked to PTB, but none of them are reliable......) followed by MIP-1β, GM-CSF, Eotaxin, and TNF-RI (two studies) were reported more than once in maternal serum. However, results could not be combined due to heterogeneity in type of sample, study population, assay, and analysis methods. By this systematic review, we conclude that multiplex assays...

  13. Spontaneous Strategies in Innovation Networks

    DEFF Research Database (Denmark)

    Plesner, Ursula; Husted, Emil Krastrup

    and a site ontology, we show how physical sites and objects become constitutive of the inside of virtual worlds through innovation processes. This argument is in line with ANT’s perspective on strategy, where sites and objects are considered a strategically relevant resource in the innovation process...... of materiality in relation to the organization and structuring of virtual worlds. We examine various innovation processes in five Danish entrepreneurial companies where actors continuously struggle to stabilize virtual worlds as platforms for professional communication. With inspiration from actor-network theory....... Empirically, the analysis is founded on descriptive accounts from the five entrepreneurs. By highlighting the spontaneous strategies described by actors, we show how sites and objects are actively used as an element in their strategy, and also how the sites and objects end up facilitating new ways of thinking...

  14. Recurrent spontaneous attacks of dizziness.

    Science.gov (United States)

    Lempert, Thomas

    2012-10-01

    This article describes the common causes of recurrent vertigo and dizziness that can be diagnosed largely on the basis of history. Ninety percent of spontaneous recurrent vertigo and dizziness can be explained by six disorders: (1) Ménière disease is characterized by vertigo attacks, lasting 20 minutes to several hours, with concomitant hearing loss, tinnitus, and aural fullness. Aural symptoms become permanent during the course of the disease. (2) Attacks of vestibular migraine may last anywhere from minutes to days. Most patients have a previous history of migraine headaches, and many experience migraine symptoms during the attack. (3) Vertebrobasilar TIAs affect older adults with vascular risk factors. Most attacks last less than 1 hour and are accompanied by other symptoms from the posterior circulation territory. (4) Vestibular paroxysmia is caused by vascular compression of the eighth cranial nerve. It manifests itself with brief attacks of vertigo that recur many times per day, sometimes with concomitant cochlear symptoms. (5) Orthostatic hypotension causes brief episodes of dizziness lasting seconds to a few minutes after standing up and is relieved by sitting or lying down. In older adults, it may be accompanied by supine hypertension. (6) Panic attacks usually last minutes, occur in specific situations, and are accompanied by choking, palpitations, tremor, heat, and anxiety. Less common causes of spontaneous recurrent vertigo and dizziness include perilymph fistula, superior canal dehiscence, autoimmune inner ear disease, otosclerosis, cardiac arrhythmia, and medication side effects. Neurologists need to venture into otolaryngology, internal medicine, and psychiatry to master the differential diagnosis of recurrent dizziness.

  15. Crows spontaneously exhibit analogical reasoning.

    Science.gov (United States)

    Smirnova, Anna; Zorina, Zoya; Obozova, Tanya; Wasserman, Edward

    2015-01-19

    Analogical reasoning is vital to advanced cognition and behavioral adaptation. Many theorists deem analogical thinking to be uniquely human and to be foundational to categorization, creative problem solving, and scientific discovery. Comparative psychologists have long been interested in the species generality of analogical reasoning, but they initially found it difficult to obtain empirical support for such thinking in nonhuman animals (for pioneering efforts, see [2, 3]). Researchers have since mustered considerable evidence and argument that relational matching-to-sample (RMTS) effectively captures the essence of analogy, in which the relevant logical arguments are presented visually. In RMTS, choice of test pair BB would be correct if the sample pair were AA, whereas choice of test pair EF would be correct if the sample pair were CD. Critically, no items in the correct test pair physically match items in the sample pair, thus demanding that only relational sameness or differentness is available to support accurate choice responding. Initial evidence suggested that only humans and apes can successfully learn RMTS with pairs of sample and test items; however, monkeys have subsequently done so. Here, we report that crows too exhibit relational matching behavior. Even more importantly, crows spontaneously display relational responding without ever having been trained on RMTS; they had only been trained on identity matching-to-sample (IMTS). Such robust and uninstructed relational matching behavior represents the most convincing evidence yet of analogical reasoning in a nonprimate species, as apes alone have spontaneously exhibited RMTS behavior after only IMTS training. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Measurement of the $\\Omega_{c}^{0}$ lifetime

    CERN Document Server

    Adamovich, M.I.; Alexandrov, Yu.A.; Barberis, D.; Beck, M.; Berat, C.; Beusch, W.; Boss, M.; Brons, S.; Bruckner, W.; Buenerd, M.; Buscher, C.; Charignon, F.; Chauvin, J.; Chudakov, E.A.; Dropmann, F.; Engelfried, J.; Faller, F.; Fournier, A.; Gerasimov, S.; Godbersen, M.; Grafstrom, P.; Haller, T.; Heidrich, M.; Hurst, R.B.; Konigsmann, Kay; Konorov, I.; Martens, K.; Martin, P.; Masciocchi, S.; Michaels, R.; Muller, U.; Newsom, C.; Paul, S.; Povh, B.; Ren, Z.; Rey-Campagnolle, M.; Rosner, G.; Rossi, L.; Rudolph, H.; Schmitt, L.; Siebert, H.W.; Simon, A.; Smith, V.J.; Thilmann, O.; Trombini, A.; Vesin, E.; Volkemer, B.; Vorwalter, K.; Walcher, T.; Walder, G.; Werding, R.; Wittmann, E.; Zavertyaev, M.V.

    1995-01-01

    We present the measurement of the lifetime of the Omega_c we have performed using three independent data samples from two different decay modes. Using a Sigma- beam of 340 GeV/c we have obtained clean signals for the Omega_c decaying into Xi- K- pi+ pi+ and Omega- pi+ pi- pi+, avoiding topological cuts normally used in charm analysis. The short but measurable lifetime of the Omega_c is demonstrated by a clear enhancement of the signals at short but finite decay lengths. Using a continuous maximum likelihood method we determined the lifetime to be tau(Omega_c) = 55 +13-11(stat) +18-23(syst) fs. This makes the Omega_c the shortest living weakly decaying particle observed so far. The short value of the lifetime confirms the predicted pattern of the charmed baryon lifetimes and demonstrates that the strong interaction plays a vital role in the lifetimes of charmed hadrons.

  17. [Fluorescence lifetime measurement based on different pump waveform].

    Science.gov (United States)

    Huang, Xiu-jun; Chen, Jian-guo; Feng, Guo-ying; Yang, Li-ling; Deng, Guo-liang; Tang, Xiao-jun; Zhou, Shou-huan

    2010-11-01

    The present paper analyzes the different pump wave theory under the fluorescence decay law, and presents a different pump wave measured fluorescence lifetime of the new method-double-pulse detection method, namely the use of pump pulse and probe pulse for the fluorescence decay methods to measure fluorescence lifetime. By measuring the sample neodymium glass and Cr:ZnSe crystal fluorescence lifetime, results showed that: using this method can be achieved under different pump wave in visible and near-infrared to the mid-infrared laser medium of the fluorescence lifetime measurement. Therefore, using the measurement method can be convenient and effective to avoid seeking samples by deconvolution for fluorescence lifetime with the cumbersome process of measuring laser medium at different pump wave under the fluorescence lifetime with a reference value.

  18. LHCb: Measurement of $b$-hadron lifetimes at LHCb

    CERN Multimedia

    Amhis, Y

    2014-01-01

    Lifetimes are among the most fundamental properties of elementary particles. Precision Measurements of $b$-hadron lifetimes are an important tool to test theoretical models such as HQET. These models allow to predict various observables related to B-mixing. Using data collected during Run 1 at the LHC, LHCb measured the lifetime of B-decays including a $J/\\psi$ in the final state.

  19. Insight into carrier lifetime impact on band-modulation devices

    Science.gov (United States)

    Parihar, Mukta Singh; Lee, Kyung Hwa; Park, Hyung Jin; Lacord, Joris; Martinie, Sébastien; Barbé, Jean-Charles; Xu, Yue; El Dirani, Hassan; Taur, Yuan; Cristoloveanu, Sorin; Bawedin, Maryline

    2018-05-01

    A systematic study to model and characterize the band-modulation Z2-FET device is developed bringing light to the relevance of the carrier lifetime influence. This work provides guidelines to optimize the Z2-FETs for sharp switching, ESD protection, and 1T-DRAM applications. Lower carrier lifetime in the Z2-FET helps in attaining the sharp switch. We provide new insights into the correlation between generation/recombination, diffusion, electrostatic barriers and carrier lifetime.

  20. Stabiliteit spontane taal bij chronische milde afasie

    NARCIS (Netherlands)

    Wolthuis, Nienke; Mendez Orellana, Carolina; Nouwens, Femke; Jonkers, Roel; Visch-Brink, Evy; Bastiaanse, Roelien

    2014-01-01

    In aphasia, an analysis of spontaneous speech provides opportunities to establish the linguistic and communicative abilities, to create suitable therapy plans and to measure language progress. The current study investigated the stability of spontaneous speech within an interview of ten mild aphasic

  1. Spontaneously broken abelian gauge invariant supersymmetric model

    International Nuclear Information System (INIS)

    Mainland, G.B.; Tanaka, K.

    A model is presented that is invariant under an Abelian gauge transformation and a modified supersymmetry transformation. This model is broken spontaneously, and the interplay between symmetry breaking, Goldstone particles, and mass breaking is studied. In the present model, spontaneously breaking the Abelian symmetry of the vacuum restores the invariance of the vacuum under a modified supersymmetry transformation. (U.S.)

  2. Spontaneous Achilles tendon rupture in alkaptonuria | Mohammed ...

    African Journals Online (AJOL)

    Spontaneous Achilles tendon ruptures are uncommon. We present a 46-year-old man with spontaneous Achilles tendon rupture due to ochronosis. To our knowledge, this has not been previously reported in Sudan literature. The tendon of the reported patient healed well after debridement and primary repairs.

  3. Spontaneous rupture of choledochal cyst: case report

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ho Seob; Nam, Kyung Jin; Lee, Jin Hwa; Kim, Chan Sung; Choi, Jong Cheol; Oh, Jong Young [Dong-a University College of Medicine, Pusan (Korea, Republic of)

    2002-11-01

    Spontaneous rupture of a choledochal cyst leading to biliary peritonitis is a rare complication which can be fatal if not promptly diagnosed. The authors report the ultrasound and CT findings of two cases of spontaneous choledochal cystic rupture and the biliary peritonitis which ensued.

  4. Spontaneity and Equilibrium II: Multireaction Systems

    Science.gov (United States)

    Raff, Lionel M.

    2014-01-01

    The thermodynamic criteria for spontaneity and equilibrium in multireaction systems are developed and discussed. When N reactions are occurring simultaneously, it is shown that G and A will depend upon N independent reaction coordinates, ?a (a = 1,2, ..., N), in addition to T and p for G or T and V for A. The general criteria for spontaneity and…

  5. Crystallization-mediated amorphous CuxO (x = 1, 2)/crystalline CuI p-p type heterojunctions with visible light enhanced and ultraviolet light restrained photocatalytic dye degradation performance

    Science.gov (United States)

    Wang, Hongli; Cai, Yun; Zhou, Jian; Fang, Jun; Yang, Yang

    2017-04-01

    We report simple and cost-effective fabrication of amorphous CuxO (x = 1, 2)/crystalline CuI p-p type heterojunctions based on crystallization-mediated approaches including antisolvent crystallization and crystal reconstruction. Starting from CuI acetonitrile solution, large crystals in commercial CuI can be easily converted to aggregates consisting of small particles by the crystallization processes while the spontaneous oxidation of CuI by atmospheric/dissolved oxygen can induce the formation of trace CuxO on CuI surface. As a proof of concept, the as-fabricated CuxO/CuI heterojunctions exhibit effective photocatalytic activity towards the degradation of methyl blue and other organic pollutants under visible light irradiation, although the wide band-gap semiconductor CuI is insensible to visible light. Unexpectedly, the CuxO/CuI heterojunctions exhibit restrained photocatalytic activity when ultraviolet light is applied in addition to the visible. It is suggested that the CuxO/CuI interface can enhance the spatial separation of the electron-hole pairs with the excitation of CuxO under visible light and prolong the lifetime of photogenerated charges with high redox ability. The present work represents a critically important step in advancing the crystallization technique for potential mass production of semiconductor heterojunctions in a mild manner.

  6. Multiexciton fluorescence from semiconductor nanocrystals

    International Nuclear Information System (INIS)

    Fisher, Brent; Caruge, Jean-Michel; Chan, Y.-T.; Halpert, Jonathan; Bawendi, Moungi G.

    2005-01-01

    We use transient photoluminescence to spectrally resolve the emission from 1, 2, and 3 electron-hole pairs states in CdSe colloidal nanocrystals with radii ranging between 2.3 and 5.2 nm. Temporally and spectrally resolved multiexciton emission from single NCs is also observed. The observation of multiexciton emission enables new experiments and potential applications at both the single NC level and using ensembles of NCs. First we discuss the use of single CdSe(CdZnS) core(shell) colloidal NCs (spheres and rods) to generate triggered photon pair emission at room temperature, with specific ordering of the pair's constituent photons. Second, we incorporate CdSe/ZnS core-shell nanocrystals into a TiO 2 host matrix and observe simultaneous two-state amplified spontaneous emission and lasing from both multiexcitonic transitions (1S 3/2 -1S e and 1P 3/2 -1P e ) in a surface-emitting distributed feedback CdSe NC laser. From our data we deduce radiative lifetimes, quantum yields, stimulated emission gain, and power dependencies for the multiexciton transitions

  7. Customer Lifetime and After Lifetime Value - Calculations from an Iranian perspective

    DEFF Research Database (Denmark)

    Hollensen, Svend; Wilson, Jonathan A.J.; Ebrahimi, Mehdi

    2011-01-01

    Customer Lifetime Value (CLV) is an established relationship marketing-centric approach to evaluating the significance of a customer, and what resources should be allocated towards maintaining relations – beyond short-term transactional views. The conceptual argument presented in this paper contr...... in the afterlife. The aim here, is to refine value-based calculations, drawing from varying religious perspectives: reincarnation, heaven, and enlightenment, amongst others....

  8. Modification of spontaneous emission from nanodiamond colour centres on a structured surface

    International Nuclear Information System (INIS)

    Inam, F A; Gaebel, T; Bradac, C; Withford, M J; Rabeau, J R; Steel, M J; Stewart, L; Dawes, J M

    2011-01-01

    Colour centres in diamond are promising candidates as a platform for quantum technologies and biomedical imaging based on spins and/or photons. Controlling the emission properties of colour centres in diamond is a key requirement for the development of efficient single-photon sources having high collection efficiency. A number of groups have achieved an enhancement in the emission rate over narrow wavelength ranges by coupling single emitters in nanodiamond crystals to resonant electromagnetic structures. In this paper, we characterize in detail the spontaneous emission rates of nitrogen-vacancy centres at various locations on a structured substrate. We found a factor of 1.5 average enhancement of the total emission rate when nanodiamonds are on an opal photonic crystal surface, and observed changes in the lifetime distribution. We present a model for explaining these observations and associate the lifetime properties with dipole orientation and polarization effects.

  9. Modification of spontaneous emission from nanodiamond colour centres on a structured surface

    Energy Technology Data Exchange (ETDEWEB)

    Inam, F A; Gaebel, T; Bradac, C; Withford, M J; Rabeau, J R; Steel, M J [Centre for Quantum Science and Technology, Department of Physics and Astronomy, Macquarie University, Sydney, NSW 2109 (Australia); Stewart, L; Dawes, J M, E-mail: james.rabeau@mq.edu.au, E-mail: michael.steel@mq.edu.au [MQ Photonics Research Centre, Department of Physics and Astronomy, Macquarie University, Sydney, NSW 2109 (Australia)

    2011-07-15

    Colour centres in diamond are promising candidates as a platform for quantum technologies and biomedical imaging based on spins and/or photons. Controlling the emission properties of colour centres in diamond is a key requirement for the development of efficient single-photon sources having high collection efficiency. A number of groups have achieved an enhancement in the emission rate over narrow wavelength ranges by coupling single emitters in nanodiamond crystals to resonant electromagnetic structures. In this paper, we characterize in detail the spontaneous emission rates of nitrogen-vacancy centres at various locations on a structured substrate. We found a factor of 1.5 average enhancement of the total emission rate when nanodiamonds are on an opal photonic crystal surface, and observed changes in the lifetime distribution. We present a model for explaining these observations and associate the lifetime properties with dipole orientation and polarization effects.

  10. Early pregnancy angiogenic markers and spontaneous abortion

    DEFF Research Database (Denmark)

    Andersen, Louise B; Dechend, Ralf; Karumanchi, S Ananth

    2016-01-01

    BACKGROUND: Spontaneous abortion is the most commonly observed adverse pregnancy outcome. The angiogenic factors soluble Fms-like kinase 1 and placental growth factor are critical for normal pregnancy and may be associated to spontaneous abortion. OBJECTIVE: We investigated the association between...... maternal serum concentrations of soluble Fms-like kinase 1 and placental growth factor, and subsequent spontaneous abortion. STUDY DESIGN: In the prospective observational Odense Child Cohort, 1676 pregnant women donated serum in early pregnancy, gestational week ..., interquartile range 71-103). Concentrations of soluble Fms-like kinase 1 and placental growth factor were determined with novel automated assays. Spontaneous abortion was defined as complete or incomplete spontaneous abortion, missed abortion, or blighted ovum

  11. Reactor pressure vessel embrittlement of NPP borssele: Design lifetime and lifetime extension

    International Nuclear Information System (INIS)

    Blom, F.J.

    2007-01-01

    Embrittlement of the reactor pressure vessel of the Borssele nuclear power plant has been investigated taking account of the design lifetime of 40 years and considering 20 years subsequent lifetime extension. The paper presents the current licensing status based on considerations of material test data and of US nuclear regulatory standards. Embrittlement status is also evaluated against German and French nuclear safety standards. Results from previous fracture toughness and Charpy tests are investigated by means of the Master curve toughness transition approach. Finally, state of the art insights are investigated by means of literature research. Regarding the embrittlement status of the reactor pressure vessel of Borssele nuclear power plant it is concluded that there is a profound basis for the current license up to the original end of the design life in 2013. The embrittlement temperature changes only slightly with respect to the acceptance criterion adopted postulating further operation up to 2033. Continued safe operation and further lifetime extension are therefore not restricted by reactor pressure vessel embrittlement

  12. The (perceived) meaning of spontaneous thoughts.

    Science.gov (United States)

    Morewedge, Carey K; Giblin, Colleen E; Norton, Michael I

    2014-08-01

    Spontaneous thoughts, the output of a broad category of uncontrolled and inaccessible higher order mental processes, arise frequently in everyday life. The seeming randomness by which spontaneous thoughts arise might give people good reason to dismiss them as meaningless. We suggest that it is precisely the lack of control over and access to the processes by which they arise that leads people to perceive spontaneous thoughts as revealing meaningful self-insight. Consequently, spontaneous thoughts potently influence judgment. A series of experiments provides evidence supporting two hypotheses. First, we hypothesize that the more a thought is perceived to be spontaneous, the more it is perceived to provide meaningful self-insight. Participants perceived more spontaneous kinds of thought (e.g., intuition) to reveal greater self-insight than did more controlled kinds of thought in Study 1 (e.g., deliberation). In Studies 2 and 3, participants perceived thoughts with the same content and target to reveal greater self-insight when spontaneously rather than deliberately generated (i.e., childhood memories and impressions formed). Second, we hypothesize that the greater self-insight attributed to thoughts that are (perceived to be) spontaneous leads those thoughts to more potently influence judgment. Participants felt more sexually attracted to an attractive person whom they thought of spontaneously than deliberately in Study 4, and reported their commitment to a current romantic relationship would be more affected by the spontaneous rather than deliberate recollection of a good or bad experience with their romantic partner in Study 5. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  13. Life-time of hot nuclei

    International Nuclear Information System (INIS)

    Aboufirassi, M.; Bougault, R.; Brou, R.; Colin, J.; Durand, D.; Genoux-Lubain, A.; Horn, D.; Laville, J.L.; Le Brun, C.; Lecolley, J.F.; Lopez, O.; Louvel, M.; Mahi, M.; Meslin, C.; Steckmeyer, J.C.; Tamain, B.

    1998-01-01

    The study of the systems Ne + Au, Ar + Au and Kr + Au has allowed description of the de-excitation and particularly the evolution of the fragment emission time intervals as o function of the compound system excitation energy. The analysis of data obtained by the multidetector NAUTILUS for Pb + Au at 29 MeV/u has permitted the access to another time scale: the lifetime of the two partners before fragmentation. For this system and this energy the predominant process is primarily a two-body process analogue to that observed at lower energies (deep inelastic transfer). This mechanism can lead to a complete relaxation energy and consequently to low relative velocities between the two partners in the exit channel. In contrast to the low energy process where the two partners decay by evaporation, here the energy implied may lead to the rupture of one and/or the other partner in several fragments (2 to 5). For the the most relaxed events the excitation energies may reach the values of 6 MeV/u. Simulations were realized in which the entrance channel i.e. the relaxation of the two partners is described by a classical trajectory calculation. In the exit channel after a time τ one of the two partners splits in several fragments. The study of the trajectories of these fragments allows the determination of the angular distributions relative to the direction of the un-split partner. The comparison between this calculation and the data is given. The τ values vary from a negative value corresponding to a rupture during the interaction of two partners up to a τ of 200 fm/c. The best fit indicates a τ 100 fm/c, this showing that the lifetime of the splitting nucleus is of the order of 100 fm/c after separation of the two partners. By comparing this result with microscopic models one can obtain a better understanding of the system rupture scenario. This study is under way

  14. Explore the Lifetime Frontiers with MATHUSLA Detector

    CERN Document Server

    Zhang, Ce; CERN. Geneva. EP Department

    2017-01-01

    Many extensions of the Standard Model (SM) include particles that are neutral, weakly coupled, and long-lived that can decay to final states containing several hadronic jets. Long-lived particles (LLPs) can be detected as displaced decays from the interaction point, or missing energy if they escape. ATLAS and CMS have performed searches at the LHC and significant exclusion limits have been set in recent years. However, the current searches performed at colliders have limitations. An LLP does not interact with the detector and it is only visible once it decays. Unfortunately, no existing or proposed search strategy will be able to observe the decay of non-hadronic electrically neutral LLPs with masses above ~ GeV and lifetimes near the limit set by Big Bang Nucleosynthesis ($c\\tau \\sim 10^7-10^8 m$). Therefore, ultra-long-lived particles (ULLPs) produced at the LHC will escape the main detector with extremely high probability. MATHUSLA (MAssive Timing Hodoscope for Ultra Stable neutraL pArticles) is a surface ...

  15. Andrew shortens lifetime of Louisiana Barrier Islands

    Science.gov (United States)

    Bush, Susan

    Because the Isles Dernieres, a series of four barrier islands off the coast of Louisiana, have one of the most rapidly eroding shorelines in the world, geologists at the U.S. Geological Survey and the Louisiana Geological Survey have been monitoring erosion activity over the last several years, said Jeff Williams of the USGS in Reston, Va. Hurricane Andrew, which struck the state on August 26, caused severe erosional damage to these islands that has shortened their lifetimes.Before Andrew struck, geologists projected that Raccoon Island would disappear below sea level by the year 2001 and that Whiskey Island would disappear by 2016. Now, due to the severe erosion from Hurricane Andrew, the scientists claim that the islands may disappear before the turn of the century, and the other islands in the Dernieres chain are expected to follow suit within 2 decades. Raccoon, Whiskey, Trinity, and East islands make up the Isles Dernieres, which existed as one island, known as the Isle Derniere, before an 1856 hurricane and subsequent erosion.

  16. An approach to systematic structural lifetime management

    International Nuclear Information System (INIS)

    Talja, H.; Solin, J.; Rintamaa, R.

    2000-01-01

    Many utilities are currently developing preventive maintenance and plant life management systems for their own use. Consideration of plant specific design and integrity problems support use of tailored programs and/or data bases for plant life management. The final applications will be developed on plant type, utility, plant or system level. However, common features can be included in the systems. The project Plant life management XVO conducted at VTT deals - as a whole - with systematic component lifetime management, operational loads in normal steady state operation and in transients, especially piping vibrations and integrity, NDE, materials ageing, interactions of coolant and materials, environmentally assisted cracking and ageing of reactor internals. One of the major challenges in the project is to define, how these multidisciplinary results should be integrated such that quantitative assessments on remaining safe life and failure risks are possible. In this paper a brief overview on the project is given. The work performed on piping vibration and integrity management is presented in more detail. (author)

  17. Decreasing luminescence lifetime of evaporating phosphorescent droplets

    Science.gov (United States)

    van der Voort, D. D.; Dam, N. J.; Sweep, A. M.; Kunnen, R. P. J.; van Heijst, G. J. F.; Clercx, H. J. H.; van de Water, W.

    2016-12-01

    Laser-induced phosphorescence has been used extensively to study spray dynamics. It is important to understand the influence of droplet evaporation in the interpretation of such measurements, as it increases luminescence quenching. By suspending a single evaporating n-heptane droplet in an acoustic levitator, the properties of lanthanide-complex europium-thenoyltrifluoroacetone-trioctylphosphine oxide (Eu-TTA-TOPO) phosphorescence are determined through high-speed imaging. A decrease was found in the measured phosphorescence decay coefficient (780 → 200 μs) with decreasing droplet volumes (10-9 → 10-11 m3) corresponding to increasing concentrations (10-4 → 10-2 M). This decrease continues up to the point of shell-formation at supersaturated concentrations. The diminished luminescence is shown not to be attributable to triplet-triplet annihilation, quenching between excited triplet-state molecules. Instead, the pure exponential decays found in the measurements show that a non-phosphorescent quencher, such as free TTA/TOPO, can be attributable to this decay. The concentration dependence of the phosphorescence lifetime can therefore be used as a diagnostic of evaporation in sprays.

  18. Lifetime of titanium filament at constant current

    International Nuclear Information System (INIS)

    Chou, T.S.; Lanni, C.

    1981-01-01

    Titanium Sublimation Pump (TSP) represents the most efficient and the least expensive method to produce Ultra High Vacuum (UHV) in storage rings. In ISABELLE, a proton storage accelerator under construction at Brookhaven National Laboratory, for example, TSP provides a pumping speed for hydrogen of > 2 x 10 6 l/s. Due to the finite life of titanium filaments, new filaments have to be switched in before the end of filament burn out, to ensure smooth operation of the accelerator. Therefore, several operational modes that can be used to activate the TSP were studied. The constant current mode is a convenient way of maintaining constant evaporating rate by increasing the power input while the filament diameter decreases as titanium evaporates. The filaments used in this experiment were standard Varian 916-0024 filaments made of Ti 85%, Mo 15% alloy. During their lifetime at a constant current of 48 amperes, the evaporation rate rose to a maximum at about 10% of their life and then flattened out to a constant value, 0.25 g/hr. The maximum evaporation rate occurs coincidently with the recrystallization of 74% Ti 26% Mo 2 from microstructure crystalline at higher titanium concentration to macrostructure crystalline at lower titanium concentration. As the macrocrystal grows, the slip plane develops at the grain boundary resulting in high resistance at the slip plane which will eventually cause the filament burn out due to local heating

  19. Radiative lifetime measurements of rubidium Rydberg states

    International Nuclear Information System (INIS)

    Branden, D B; Juhasz, T; Mahlokozera, T; Vesa, C; Wilson, R O; Zheng, M; Tate, D A; Kortyna, A

    2010-01-01

    We have measured the radiative lifetimes of ns, np and nd Rydberg states of rubidium in the range 28 ≤ n ≤ 45. To enable long-lived states to be measured, our experiment uses slow-moving (∼100 μK) 85 Rb atoms in a magneto-optical trap (MOT). Two experimental techniques have been adopted to reduce random and systematic errors. First, a narrow-bandwidth pulsed laser is used to excite the target nl Rydberg state, resulting in minimal shot-to-shot variation in the initial state population. Second, we monitor the target state population as a function of time delay from the laser pulse using a short-duration, millimetre-wave pulse that is resonant with a one- or two-photon transition to a higher energy 'monitor state', n'l'. We then selectively field ionize the monitor state, and detect the resulting electrons with a micro-channel plate. This signal is an accurate mirror of the nl target state population, and is uncontaminated by contributions from other states which are populated by black body radiation. Our results are generally consistent with other recent experimental results obtained using a method which is more prone to systematic error, and are also in excellent agreement with theory.

  20. Ultrafast optical generation of squeezed magnon states and long lifetime coherent LO phonons

    Science.gov (United States)

    Zhao, Jimin

    2005-12-01

    Ultrafast optical pulses have been used to generate, probe, and control low-energy elementary excitations in crystals. In particular, we report the first experimental demonstration of the generation of quantum squeezed states of magnons (collective spin-wave excitations) in a magnetic material, and new progress in experimental investigation of anharmonic interactions in a semiconductor. The mechanism for the magnon squeezing is two-magnon impulsive stimulated Raman scattering (ISRS). Femtosecond laser pulses have been used to coherently correlate degenerate counter-propagating magnons in the antiferromagnetic insulator MnF2. In the squeezed state, fluctuations of the magnetization of a crystallographic unit cell vary periodically in time and are reduced below that of the ground-state quantum noise. Similar experiments were also performed in another antiferromagnetic insulator, FeF2, for which the squeezing effect is one order of magnitude larger. We have also investigated the anharmonic interaction of the low-frequency E2 phonon in ZnO through ISRS. Temperature dependence of the linewidth and frequency indicates that the two-phonon up-conversion process is the dominant decay channel and isotopic disorder may be the main limit on the lifetime at low temperature. We have observed the longest lifetime of an optical phonon mode in a solid (211 ps at 5 K). And we have found that pump-probe experiments, compared with spontaneous Raman spectroscopy, have extremely high accuracy in determining the frequency of a low-lying excitation.

  1. Spontaneous Metacognition in Rhesus Monkeys.

    Science.gov (United States)

    Rosati, Alexandra G; Santos, Laurie R

    2016-09-01

    Metacognition is the ability to think about thinking. Although monitoring and controlling one's knowledge is a key feature of human cognition, its evolutionary origins are debated. In the current study, we examined whether rhesus monkeys (Macaca mulatta; N = 120) could make metacognitive inferences in a one-shot decision. Each monkey experienced one of four conditions, observing a human appearing to hide a food reward in an apparatus consisting of either one or two tubes. The monkeys tended to search the correct location when they observed this baiting event, but engaged in information seeking-by peering into a center location where they could check both potential hiding spots-if their view had been occluded and information seeking was possible. The monkeys only occasionally approached the center when information seeking was not possible. These results show that monkeys spontaneously use information about their own knowledge states to solve naturalistic foraging problems, and thus provide the first evidence that nonhumans exhibit information-seeking responses in situations with which they have no prior experience. © The Author(s) 2016.

  2. Spontaneous flocking in human groups.

    Science.gov (United States)

    Belz, Michael; Pyritz, Lennart W; Boos, Margarete

    2013-01-01

    Flocking behaviour, as a type of self-organised collective behaviour, is described as the spatial formation of groups without global control and explicit inter-individual recruitment signals. It can be observed in many animals, such as bird flocks, shoals or herds of ungulates. Spatial attraction between humans as the central component of flocking behaviour has been simulated in a number of seminal models but it has not been detected experimentally in human groups so far. The two other sub-processes of this self-organised collective movement - collision avoidance and alignment - are excluded or held constant respectively in this study. We created a computer-based, multi-agent game where human players, represented as black dots, moved on a virtual playground. The participants were deprived of social cues about each other and could neither communicate verbally nor nonverbally. They played two games: (1) Single Game, where other players were invisible, and (2) Joint Game, where each player could see players' positions in a local radius around himself/herself. We found that individuals approached their neighbours spontaneously if their positions were visible, leading to less spatial dispersion of the whole group compared to moving alone. We conclude that human groups show the basic component of flocking behaviour without being explicitly instructed or rewarded to do so. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Simultaneous bilateral primary spontaneous pneumothorax

    Directory of Open Access Journals (Sweden)

    Arife Zeybek

    2014-04-01

    Full Text Available Simultaneous bilateral primary pneumothorax is a very rare (1.6 / 100,000 and life-threatening condition. Clinical presentation may vary from mild dyspnea to tension pneumothorax. It may be milder particularly in younger patients, but more severe in patients with advanced age, and tube thoracostomy is a life preserver in the latter group. Since mortality and recurrence rates following tube thoracostomy are high, endoscopic approaches to bilateral hemithorax have been reported in literature. Apical wedge resection and pleural procedures are recommended in video thoracoscopy or mini thoracotomy even if no bulla and/or bleb are detected. Bilateral surgical interventions and additional pleural procedures are associated with increased rate of post-operative complications and longer postoperative hospital-stays. As a first-line approach, the surgical method toward any side of lung with air leakage following a previous tube thoracostomy is considered less invasive, especially in younger patients. Here, we present a case of simultaneous bilateral primary spontaneous pneumothorax (SBPSP in a 21-year old male with no history of smoking and chronic pulmonary disease. A unilateral surgical intervention was performed, and no recurrence was observed during 5-year follow up.

  4. Bilateral spontaneous hemotympanum: Case report

    Directory of Open Access Journals (Sweden)

    Economou Nicolas C

    2006-10-01

    Full Text Available Abstract Background The most common causes of hemotympanum are therapeutic nasal packing, epistaxis, blood disorders and blunt trauma to the head. Hemotympanum is characterized as idiopathic, when it is detected in the presence of chronic otitis media. A rare case of spontaneous bilateral hemotympanum in a patient treated with anticoagulants is presented herein. Case presentation A 72-year-old male presented with acute deterioration of hearing. In the patient's medical history aortic valve replacement 1 year before presentation was reported. Since then he had been administered regularly coumarinic anticoagulants, with INR levels maintained between 3.4 and 4.0. Otoscopy revealed the presence of bilateral hemotympanum. The audiogram showed symmetrical moderately severe mixed hearing loss bilaterally, with the conductive component predominating. Tympanograms were flat bilaterally with absent acoustic reflexes. A computerized tomography scan showed the presence of fluid in the mastoid and middle ear bilaterally. Treatment was conservative and consisted of a 10-day course of antibiotics, anticongestants and temporary interruption of the anticoagulant therapy. After 3 weeks, normal tympanic membranes were found and hearing had returned to previous levels. Conclusion Anticoagulant intake should be included in the differential diagnosis of hemotympanum, because its detection and appropriate treatment may lead to resolution of the disorder.

  5. The Lifetime Prediction of LED Drivers and Lamps

    NARCIS (Netherlands)

    Sun, B.

    2017-01-01

    Light-Emitting Diodes (LEDs) have become a very promising alternative lighting source with the main advantages of a longer lifetime and a higher efficiency than traditional ones. However, the LED lamp’s lifetime is compromised by its driver’s reliability. Although extensive studies have been made on

  6. Optimal Taxation and Social Insurance in a Lifetime Perspective

    NARCIS (Netherlands)

    Bovenberg, A.L.; Sorensen, P.B.

    2006-01-01

    Advances in information technology have improved the administrative feasibility of redistribution based on lifetime earnings recorded at the time of retirement. We study optimal lifetime income taxation and social insurance in an economy in which redistributive taxation and social insurance serve to

  7. Optimal Taxation and Social Insurance in a Lifetime Perspective

    NARCIS (Netherlands)

    Bovenberg, A.L.; Sorensen, P.B.

    2007-01-01

    Advances in information technology have improved the administrative feasibility of redis- tribution based on lifetime earnings recorded at the time of retirement. We study optimal lifetime income taxation and social insurance in an economy in which redistributive taxation and social insurance serve

  8. Evaluation of Battery Lifetimes using Inhomogeneous Markov Reward Models

    NARCIS (Netherlands)

    Cloth, L.; Haverkort, Boudewijn R.H.M.; Jongerden, M.R.

    2006-01-01

    The usage of mobile devices like cell phones, navigation systems, or laptop computers, is limited by the lifetime of the included batteries. This lifetimes depends naturally on the rate at which energy is consumed, however, it also depends on the usage pattern of the battery. Continuous drawing of a

  9. Extending the Lifetime of Sensor Networks through Adaptive Reclustering

    Directory of Open Access Journals (Sweden)

    Gianluigi Ferrari

    2007-06-01

    Full Text Available We analyze the lifetime of clustered sensor networks with decentralized binary detection under a physical layer quality-of-service (QoS constraint, given by the maximum tolerable probability of decision error at the access point (AP. In order to properly model the network behavior, we consider four different distributions (exponential, uniform, Rayleigh, and lognormal for the lifetime of a single sensor. We show the benefits, in terms of longer network lifetime, of adaptive reclustering. We also derive an analytical framework for the computation of the network lifetime and the penalty, in terms of time delay and energy consumption, brought by adaptive reclustering. On the other hand, absence of reclustering leads to a shorter network lifetime, and we show the impact of various clustering configurations under different QoS conditions. Our results show that the organization of sensors in a few big clusters is the winning strategy to maximize the network lifetime. Moreover, the observation of the phenomenon should be frequent in order to limit the penalties associated with the reclustering procedure. We also apply the developed framework to analyze the energy consumption associated with the proposed reclustering protocol, obtaining results in good agreement with the performance of realistic wireless sensor networks. Finally, we present simulation results on the lifetime of IEEE 802.15.4 wireless sensor networks, which enrich the proposed analytical framework and show that typical networking performance metrics (such as throughput and delay are influenced by the sensor network lifetime.

  10. Extending the Lifetime of Sensor Networks through Adaptive Reclustering

    Directory of Open Access Journals (Sweden)

    Ferrari Gianluigi

    2007-01-01

    Full Text Available We analyze the lifetime of clustered sensor networks with decentralized binary detection under a physical layer quality-of-service (QoS constraint, given by the maximum tolerable probability of decision error at the access point (AP. In order to properly model the network behavior, we consider four different distributions (exponential, uniform, Rayleigh, and lognormal for the lifetime of a single sensor. We show the benefits, in terms of longer network lifetime, of adaptive reclustering. We also derive an analytical framework for the computation of the network lifetime and the penalty, in terms of time delay and energy consumption, brought by adaptive reclustering. On the other hand, absence of reclustering leads to a shorter network lifetime, and we show the impact of various clustering configurations under different QoS conditions. Our results show that the organization of sensors in a few big clusters is the winning strategy to maximize the network lifetime. Moreover, the observation of the phenomenon should be frequent in order to limit the penalties associated with the reclustering procedure. We also apply the developed framework to analyze the energy consumption associated with the proposed reclustering protocol, obtaining results in good agreement with the performance of realistic wireless sensor networks. Finally, we present simulation results on the lifetime of IEEE 802.15.4 wireless sensor networks, which enrich the proposed analytical framework and show that typical networking performance metrics (such as throughput and delay are influenced by the sensor network lifetime.

  11. Lifetime mental disorders and suicidal behaviour in South Africa ...

    African Journals Online (AJOL)

    Background: There is relatively little data on the relationship between lifetime mental disorders and suicidal behaviour in low and middle income countries. This study examines the relationship between lifetime mental disorders, and subsequent suicide ideation, plans, and suicide attempts in South Africa. Method: A ...

  12. Lifetime measurement of excited atomic and ionic states of some ...

    Indian Academy of Sciences (India)

    High-frequency deflection (HFD) technique with a delayed coincidence single photon counting arrangement is an efficient technique for radiative lifetime measurement. An apparatus for measurement of the radiative lifetime of atoms and molecules has been developed in our laboratory and measurements have been ...

  13. Lifetimes of machinery and equipment : evidence from Dutch manufacturing

    NARCIS (Netherlands)

    Erumban, 27675

    This paper estimates service lifetimes for capital assets in Dutch manufacturing industries, using information on asset retirement patterns. A Weibull distribution function is estimated using a non-linear regression technique to derive service lifetimes for three selected asset types: transport

  14. Estimation of the Service Lifetime of Concrete Bridges

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    In this paper estimation of the service lifetime of concrete bridges is discussed. The main reason for deterioration of concrete bridges is corrosion of the reinforcement. Therefore, modelling of the corrosion process is an important aspect of the estimation of the service lifetime. In this paper...

  15. Lifetime measurement of excited atomic and ionic states of some ...

    Indian Academy of Sciences (India)

    Abstract. High-frequency deflection (HFD) technique with a delayed coincidence single photon counting arrangement is an efficient technique for radiative lifetime measurement. An apparatus for measurement of the radiative lifetime of atoms and molecules has been developed in our laboratory and measurements have ...

  16. Precision muon lifetime and capture experiments at PSI

    NARCIS (Netherlands)

    Onderwater, C. J. G.

    2005-01-01

    The μLan experiment at the Paul Scherrer Institute will measure the lifetime of the positive muon with a precision of 1 ppm, giving a value for the Fermi coupling constant GF at the level of 0.5 ppm. Meanwhile, by measuring the observed lifetime of the negative muon in pure hydrogen, the μCap

  17. Thermal ageing analysis and lifetime prediction of IGBT inverter for ...

    African Journals Online (AJOL)

    The option of either choosing design configuration according to using the device during the entire lifetime or half of the lifetime of the solar panel was the major decision. The research findings would contribute to better adaptation of IGBT inverter-solar panel for grid electricity connectivity in relation to the replacement of the ...

  18. Mode lifetimes of stellar oscillations. Implications for asteroseismology

    DEFF Research Database (Denmark)

    Chaplin, W.J.; Houdek, G.; Karoff, Christoffer

    2009-01-01

    . Solar-like p modes are damped by convection, and hence the stability of the modes depends on the lifetime. Aims: We seek a simple scaling relation between the mean lifetime of the most prominent solar-like p modes in stars, and the fundamental stellar parameters. Methods: We base our search...

  19. Theoretical lifetimes and fluorescence yields for multiply-ionized fluorine

    International Nuclear Information System (INIS)

    Tunnell, T.W.; Can, C.; Bhalla, C.P.

    1978-01-01

    Theoretical lifetimes and multiplet partial fluorescence yields for various fluorine ions with a single K-shell vacancy were calculated. For few-electron systems, the lifetimes and line fluorescence yields were computed in the intermediate coupling scheme with the inclusion of the effects arising from configuration interactions. 6 references

  20. Level lifetimes of Au52+ in Au plasma

    International Nuclear Information System (INIS)

    Liu Bo; Zhu Zhiyan; Jiang Gang; Zhu Zhenghe

    2003-01-01

    Based on the extended relativistic multiconfiguration Dirac-Fock theory, the level lifetimes, level widths and wavelengths of Au 52+ have been calculated using the General-purpose Relativistic Atomic Structure Program. The wavelengths obtained are in good agreement with the experimental data available. The relationship between the level lifetimes and the level widths satisfies the Heisenberg uncertainty principle

  1. Quantitative analysis of fluorescence lifetime measurements of the macula using the fluorescence lifetime imaging ophthalmoscope in healthy subjects.

    Science.gov (United States)

    Dysli, Chantal; Quellec, Gwénolé; Abegg, Mathias; Menke, Marcel N; Wolf-Schnurrbusch, Ute; Kowal, Jens; Blatz, Johannes; La Schiazza, Olivier; Leichtle, Alexander B; Wolf, Sebastian; Zinkernagel, Martin S

    2014-04-03

    Fundus autofluorescence (FAF) cannot only be characterized by the intensity or the emission spectrum, but also by its lifetime. As the lifetime of a fluorescent molecule is sensitive to its local microenvironment, this technique may provide more information than fundus autofluorescence imaging. We report here the characteristics and repeatability of FAF lifetime measurements of the human macula using a new fluorescence lifetime imaging ophthalmoscope (FLIO). A total of 31 healthy phakic subjects were included in this study with an age range from 22 to 61 years. For image acquisition, a fluorescence lifetime ophthalmoscope based on a Heidelberg Engineering Spectralis system was used. Fluorescence lifetime maps of the retina were recorded in a short- (498-560 nm) and a long- (560-720 nm) spectral channel. For quantification of fluorescence lifetimes a standard ETDRS grid was used. Mean fluorescence lifetimes were shortest in the fovea, with 208 picoseconds for the short-spectral channel and 239 picoseconds for the long-spectral channel, respectively. Fluorescence lifetimes increased from the central area to the outer ring of the ETDRS grid. The test-retest reliability of FLIO was very high for all ETDRS areas (Spearman's ρ = 0.80 for the short- and 0.97 for the long-spectral channel, P macula in healthy subjects. By using a custom-built software, we were able to quantify fluorescence lifetimes within the ETDRS grid. Establishing a clinically accessible standard against which to measure FAF lifetimes within the retina is a prerequisite for future studies in retinal disease.

  2. Validity of LIDAS (LIfetime Depression Assessment Self-report): a self-report online assessment of lifetime major depressive disorder.

    Science.gov (United States)

    Bot, M; Middeldorp, C M; de Geus, E J C; Lau, H M; Sinke, M; van Nieuwenhuizen, B; Smit, J H; Boomsma, D I; Penninx, B W J H

    2017-01-01

    There is a paucity of valid, brief instruments for the assessment of lifetime major depressive disorder (MDD) that can be used in, for example, large-scale genomics, imaging or biomarker studies on depression. We developed the LIfetime Depression Assessment Self-report (LIDAS), which assesses lifetime MDD diagnosis according to DSM criteria, and is largely based on the widely used Composite International Diagnostic Interview (CIDI). Here, we tested the feasibility and determined the sensitivity and specificity for measuring lifetime MDD with this new questionnaire, with a regular CIDI as reference. Sensitivity and specificity analyses of the online lifetime MDD questionnaire were performed in adults with (n = 177) and without (n = 87) lifetime MDD according to regular index CIDIs, selected from the Netherlands Study of Depression and Anxiety (NESDA) and Netherlands Twin Register (NTR). Feasibility was tested in an additional non-selective, population-based sample of NTR participants (n = 245). Of the 753 invited persons, 509 (68%) completed the LIDAS, of which 419 (82%) did this online. User-friendliness of the instrument was rated high. Median completion time was 6.2 min. Sensitivity and specificity for lifetime MDD were 85% [95% confidence interval (CI) 80-91%] and 80% (95% CI 72-89%), respectively. This LIDAS instrument gave a lifetime MDD prevalence of 20.8% in the population-based sample. Measuring lifetime MDD with an online instrument was feasible. Sensitivity and specificity were adequate. The instrument gave a prevalence of lifetime MDD in line with reported population prevalences. LIDAS is a promising tool for rapid determination of lifetime MDD status in large samples, such as needed for genomics studies.

  3. Clock frequency estimation under spontaneous emission

    Science.gov (United States)

    Qin, Xi-Zhou; Huang, Jia-Hao; Zhong, Hong-Hua; Lee, Chaohong

    2018-02-01

    We investigate the quantum dynamics of a driven two-level system under spontaneous emission and its application in clock frequency estimation. By using the Lindblad equation to describe the system, we analytically obtain its exact solutions, which show three different regimes: Rabi oscillation, damped oscillation, and overdamped decay. From the analytical solutions, we explore how the spontaneous emission affects the clock frequency estimation. We find that under a moderate spontaneous emission rate, the transition frequency can still be inferred from the Rabi oscillation. Our results enable potential practical applications in frequency measurement and quantum control under decoherence.

  4. Spontaneous Bacterial Peritonitis in Subclinical Hypothyroidism

    Directory of Open Access Journals (Sweden)

    Dalip Gupta

    2013-11-01

    Full Text Available Hypothyroidism is an uncommon cause of ascites. Here we describe a case of a 75 year-old female patient with spontaneous bacterial peritonitis and subclinical hypothyroidism that resolved with thyroid replacement and antibiotic therapy respectively. Ascitic fluid analysis revealed a gram-positive bacterium on gram staining. A review of the literature revealed just one other reported case of myxoedema ascites with concomitant spontaneous bacterial peritonitis and no case has till been reported of spontaneous bacterial peritonitis in subclinical hypothyroidism.

  5. Spontaneous regression of an invasive thymoma.

    Science.gov (United States)

    Yutaka, Yojiro; Omasa, Mitsugu; Shikuma, Kei; Okuda, Masato; Taki, Toshihiko

    2009-05-01

    Although there are many reports of spontaneous regression of noninvasive thymoma, there are no reports of spontaneous regression of an invasive thymoma. Moreover, the mechanism of the spontaneous regression is still unknown. The present case concerns a 47-year-old man who presented with chest pain. Computed tomography (CT) showed a large anterior mediastinal mass with left pleural effusion that occluded the innominate vein. The tissue obtained by video-assisted thoracic surgery suggested a diagnosis of invasive thymic carcinoma. One month later CT showed prominent regression of the tumor, and the tumor was completely resected. On pathology, the diagnosis was thymoma type B3.

  6. Spontaneous Dissection of the Superior Mesenteric Artery

    International Nuclear Information System (INIS)

    Sheldon, Patrick J.; Esther, James B.; Sheldon, Elana L.; Sparks, Steven R.; Brophy, David P.; Oglevie, Steven B.

    2001-01-01

    Spontaneous dissection of the superior mesenteric artery (SMA) is a rare occurrence, especially when not associated with aortic dissection. Currently, only 28 cases appear to have been reported. Due to the scarcity of cases in the literature, the natural history of isolated, spontaneous SMA dissection is unclear. CT has been reported to be useful for the initial diagnosis of SMA dissection [2-5]. We present two recent cases of spontaneous SMA dissection in which enhanced spiral CT was instrumental in following the disease process and guiding clinical decision making

  7. Organic scintillators with long luminescent lifetimes for radiotherapy dosimetry

    DEFF Research Database (Denmark)

    Beierholm, Anders Ravnsborg; Lindvold, Lars René; Andersen, Claus Erik

    2011-01-01

    for radiotherapy treatments deliver pulsed beams, the stem signal can be suppressed using dosimeter materials with luminescent lifetimes much longer than that of the stem signal. However, producing organic scintillators with long luminescent lifetimes has proven difficult in practice. We report on the results...... component on the order of 20 μs was estimated for the custom-made organic scintillator, while the commercial scintillator exhibited a fast component of approximately 5 ns lifetime (7 ns as stated by the manufacturer) and an approximate 10 μs lifetime slow component. Although these lifetimes are not long...... enough for practical applications in radiotherapy dosimetry, this study supports that the stem signal can be greatly reduced by applying a temporal gating....

  8. Lifetime of {sup 44}Ti as probe for supernova models

    Energy Technology Data Exchange (ETDEWEB)

    Goerres, J.; Meissner, J.; Schatz, H.; Stech, E.; Tischhauser, P.; Wiescher, M. [Univ. of Notre Dame, Notre Dame, IN (United States); Bazin, D.; Harkewicz, R.; Hellstroem, M.; Sherrill, B.; Steiner, M. [Michigan State Univ., East Lansing, MI (United States); Boyd, R.N. [Ohio State Univ., Columbus, OH (United States); Buchmann, L. [TRIUMF, Vancouver, BC (Canada); Hartmann, D.H. [Clemson Univ., Clemson, SC (United States); Hinnefeld, J.D. [Indiana Univ. South Bend, South Bend, IN (United States)

    1998-06-01

    The recent observation of {sup 44}Ti radioactivity in the supernova remnant Cassiopeia A with the Compton Gamma Ray Observatory allows the determination of the absolute amount of {sup 44}Ti. This provides a test for current supernova models. The main uncertainty is the lifetime of {sup 44}Ti. We report a new measurement of the lifetime of {sup 44}Ti applying a novel technique. A mixed radioactive beam containing {sup 44}Ti as well as {sup 22}Na was implanted and the resulting {gamma}-activity was measured. This allowed the determination of the lifetime of {sup 44}Ti relative to the lifetime of {sup 22}Na, {tau} = (87.0 {+-} 1.9) y. With this lifetime, the {sup 44}Ti abundance agrees with theoretical predictions within the remaining observational uncertainties. (orig.)

  9. Time variation of fluorescence lifetime in enhanced cyan fluorescence protein

    International Nuclear Information System (INIS)

    Lee, Soonhyouk; Kim, Soo Yong; Park, Kyoungsook; Jeong, Jinyoung; Chung, Bong Hyun; Kim, Sok Won

    2010-01-01

    The lifetime variations of enhanced cyan fluorescence protein (ECFP) in relatively short integration time bins were studied via time-correlated single photon counting (TCSPC) measurement. We observed that minimum photon counts are necessary for the lifetime estimation to achieve a certain range of variance. The conditions to decrease the variance of lifetime were investigated and the channel width of the measurement of TCSPC data was found to be another important factor for the variance of lifetime. Though the lifetime of ECFP is best fit by a double exponential, a mono exponential fit for the same integration time is more stable. The results may be useful in the analysis of photophysical dynamics for ensemble molecules in short measurement time windows.

  10. Moisture dependence of positron lifetime in Kevlar-49

    Science.gov (United States)

    Singh, Jag J.; Holt, William H.; Mock, Willis, Jr.

    1984-01-01

    Because of filamentary character of Kevlar-49 aramid fibers, there is some concern about the moisture uptake and its effect on plastic composites reinforced with Kevlar-49 fibers. As part of continuing studies of positron lifetime in polymers, we have measured positron lifetime spectra in Kevlar-49 fibers as a function of their moisture content. The long lifetime component intensities are rather low, being only of the order of 2-3 percent. The measured values of long component lifetimes at various moisture levels in the specimens are as follows: 2072 +/- 173 ps (dry); 2013 +/- 193 ps (20.7 percent saturation); 1665 +/- 85 ps (25.7 percent saturation); 1745 +/- 257 ps (32.1 percent saturation); and 1772 +/- 217 ps (100 percent saturation). It is apparent that the long component lifetime at first decreases and then increases as the specimen moisture content increases. These results have been compared with those inferred from Epon-815 and Epon-815/K-49 composite data.

  11. Risks of a lifetime in construction part I: traumatic injuries.

    Science.gov (United States)

    Dong, Xiuwen Sue; Ringen, Knut; Welch, Laura; Dement, John

    2014-09-01

    Estimates of occupational risk are typically computed on an annual basis. In contrast, this article provides estimates of lifetime risks for fatal and nonfatal injuries among construction workers. A companion paper presents lifetime risks for occupational illnesses. Using 2003-2007 data from three large data sources, lifetime risk was computed based on the number of fatal and nonfatal injuries per 100 FTEs for a working lifespan of 45 years. For a working life in construction, the risk of fatal injuries were approximately one death per 200 FTE, and the leading causes were falls and transportation incidents. For nonfatal injuries resulting in days away from work, the adjusted lifetime risk was approximately 78 per 100 FTEs, and the leading causes were contact with objects/equipment, overexertion, and falls to a lower level. Lifetime risk estimates help inform both workers and policymakers. Despite improvements over the past decades, risks in construction remain high. © 2014 Wiley Periodicals, Inc.

  12. Does Spontaneous Favorability to Power (vs. Universalism) Values Predict Spontaneous Prejudice and Discrimination?

    Science.gov (United States)

    Souchon, Nicolas; Maio, Gregory R; Hanel, Paul H P; Bardin, Brigitte

    2017-10-01

    We conducted five studies testing whether an implicit measure of favorability toward power over universalism values predicts spontaneous prejudice and discrimination. Studies 1 (N = 192) and 2 (N = 86) examined correlations between spontaneous favorability toward power (vs. universalism) values, achievement (vs. benevolence) values, and a spontaneous measure of prejudice toward ethnic minorities. Study 3 (N = 159) tested whether conditioning participants to associate power values with positive adjectives and universalism values with negative adjectives (or inversely) affects spontaneous prejudice. Study 4 (N = 95) tested whether decision bias toward female handball players could be predicted by spontaneous attitude toward power (vs. universalism) values. Study 5 (N = 123) examined correlations between spontaneous attitude toward power (vs. universalism) values, spontaneous importance toward power (vs. universalism) values, and spontaneous prejudice toward Black African people. Spontaneous positivity toward power (vs. universalism) values was associated with spontaneous negativity toward minorities and predicted gender bias in a decision task, whereas the explicit measures did not. These results indicate that the implicit assessment of evaluative responses attached to human values helps to model value-attitude-behavior relations. © 2016 The Authors. Journal of Personality Published by Wiley Periodicals, Inc.

  13. The human resource conditions of lifetime extension

    International Nuclear Information System (INIS)

    Aszodi, A.

    2002-01-01

    Full text: According to our present knowledge, the lifetime extension of the Hungarian NPP units will be feasible, in both the technological and economic aspects. It is far more difficult, however, to answer the question whether the human resources conditions of the further application of nuclear energetics in Hungary can be satisfied. Many urgent tasks will have to be solved regarding the informing of the public and the nuclear engineering education. The training of nuclear experts is in crisis in many developed industrial countries. The university departments work with a staff mainly consisting of old and quite often near-retirement trainers and the young generation is practically missing. A particularly grave problem is (see Germany) that in a number of countries hardly any student chooses nuclear technology/engineering. Moreover, several nuclear training and research facilities have been shut down. Although the situation in Hungary is not so critical at present, the rising of the new generation of professionals may easily get into a crisis without immediate intervention. The training reactor of BUTE celebrated its 30th anniversary in 2001 and the technical conditions allow some further 20 or 25 years of operation. On the other hand, however, the age distribution of the operating staff can not be sustained even on a few-year term: the average age is 55 years, while 44% of them are retired! Although, due to financing difficulties the rejuvenation of the operating personnel has not been possible for years, it is definitely vital to maintain and develop the reactor and the ongoing educational work. By analysing the age distribution of the workers of the Hungarian energetics one can conclude: 350 to 400 young engineers will have to start work up till 2020 (i.e. 15 to 20 per year), while only 2 to 8 students graduate from the Hungarian universities who acquire some level of nuclear knowledge during their studies. In a co-operation between BUTE and the Paks NPP we are

  14. Positron annihilation lifetime spectroscopy of macromolecules

    International Nuclear Information System (INIS)

    Simon, G.

    1996-01-01

    Positron annihilation lifetime spectroscopy (PALS) is a technique which makes use of the anti- particle of the electron, the positron (e + ), first predicted by Dirac in 1931. This talk will concentrate on the use of PALS as a technique in characterising macromolecules. PALS has been used by various groups to evaluate many properties that one associates with free volume such as physical ageing, gas permeability, the glass transition, uptake of a solvent, crystallinity, crosslinking, molecular mobility. One area of much interest has been the use of this technique in looking at miscibility of polymer blends. In miscible blends, the interactions of the different polymers may be expected to lead to a negative free volume of mixing because of the strong attraction between the different chains. This may influence the free volume properties. Conversely, if a material is partially miscible or totally immiscible, this should influence both the size and total content of free volume. This should be related to other properties such as mechanical properties and molecular mobility, such as measured by dielectric relaxation spectroscopy. Variations on this involve copolymerization of crosslinked materials or linear thermoplastics (the ultimate 'molecular' miscibility) and this will also be discussed. Multiphase systems such as water uptake in polymers can vary polymer properties by filling molecular voids, as well as disturbing chain conformations and, in the case of polar polymers, associating with the polymer chains. The effect of polymer molecular structure on free volume - particularly in rigid polymer chains such as substituted poly(phenylenes) and liquid crystalline polymers will also be presented. Indeed, the unusual packing which arises from such anisotropic molecules leads to unusual behaviours both of the homolpolymers and subsequent liquid crystal polymer - liquid crystal polymer blends

  15. Extending hydraulic lifetime of iron walls

    International Nuclear Information System (INIS)

    Mackenzie, P.D.; Sivavec, T.M.; Horney, D.P.

    1997-01-01

    Iron walls for control of groundwaters contaminated with chlorinated solvents and reducible metals are becoming much more widely used and field studies of this technology have proven successful to date. However, there is still much uncertainty in predicting long-term performance. This work focuses on two factors affecting the lifetime of the iron media: plugging at the treatment zone entrance and precipitation in the bulk iron media. Plugging at the system entrance is due principally to dissolved oxygen in the incoming water and is an issue in aerobic aquifers or in ex-situ canister tests. In an in-situ treatment system, plugging would result in a dramatic reduction in flow through the iron zone. Designs to minimize plugging in field applications include use of larger iron particles and admixing sand of comparable size with the iron particles. Mineral precipitation in the bulk iron media can lead to porosity losses in the media, again reducing flow through the treatment zone. Decreases in reactivity of the iron media may also occur. The nature of the mineral precipitation and the factors that affect extent of mineral precipitation are examined by a variety of tools, including tracer tests, aqueous inorganic profiles, and surface analysis techniques. At short treatment times, measured porosity losses are due mainly to entrapment of a film of H 2 gas on the iron surfaces and also to Fe(OH) 2 precipitation. Over longer treatment times precipitation of Fe(OH) 2 and FeCO 3 in low carbonate waters and of Fe(OH) 2 , FeCO 3 and CaCO 3 in higher carbonate waters will begin to dominate porosity losses. Preliminary results of an on-going study to control pH in an iron zone by admixing iron sulfide with iron show no difference in extent of carbonate precipitation versus a 100% iron system, suggesting that these systems are supersaturated with respect to carbonate precipitation

  16. Fluorescence lifetime to image epidermal ionic concentrations

    Science.gov (United States)

    Behne, Martin J.; Barry, Nicholas P.; Moll, Ingrid; Gratton, Enrico; Mauro, Theodora M.

    2004-09-01

    Measurements of ionic concentrations in skin have traditionally been performed with an array of methods which either did not reveal detailed localization information, or only provided qualitative, not quantitative information. FLIM combines a number of advantages into a method ideally suited to visualize concentrations of ions such as H+ in intact, unperturbed epidermis and stratum corneum (SC). Fluorescence lifetime is dye concentration-independent, the method requires only low light intensities and is therefore not prone to photobleaching or phototoxic artifacts, and because multiphoton lasers of IR wavelength are used, light penetrates deep into intact tissue. The standard method to measure SC pH is the flat pH electrode, which provides reliable information only about surface pH changes, without further vertical or subcellular spatial resolution; i.e., specific microdomains such as the corneocyte interstices are not resolved, and the deeper SC is inaccessible without resorting to inherently disruptive stripping methods. Furthermore, the concept of a gradient of pH through the SC stems from such stripping experiments, but other confirmation for this concept is lacking. Our investigations into the SC pH distribution so far have revealed the crucial role of the Sodium/Hydrogen Antiporter NHE1 in generation of SC acidity, the colocalization of enzymatic lipid processing activity in the SC with acidic domains of the SC, and the timing and localization of emerging acidity in the SC of newborns. Together, these results have led to an improved understanding of the SC pH, its distribution, origin, and regulation. Future uses for this method include measurements of other ions important for epidermal processes, such as Ca2+, and a quantitative approach to topical drug penetration.

  17. Lifetime Extension Report: Progress on the SAVY-4000 Lifetime Extension Program

    Energy Technology Data Exchange (ETDEWEB)

    Welch, Cynthia F. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Smith, Paul Herrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Weis, Eric M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Blair, Michael W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Stone, Timothy Amos [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Veirs, Douglas Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Manufacturing Engineering and Technology; Reeves, Kirk Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Karns, Tristan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Oka, Jude M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Nuclear Process Infrastructure; Keller, Jennie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Meincke, Linda Jeanne [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Torres, Joseph Angelo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Herman, Matthew Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Weaver, Brian Phillip [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Computer, Computational, and Statistical Sciences. Statistical Sciences; Adams, Jillian Cathleen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials; Trautschold, Olivia Carol [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Materials Science and Technology. Engineered Materials

    2016-09-20

    The 3-year accelerated aging study of the SAVY-4000 O-ring shows very little evidence of significant degradation to samples subjected to aggressive elevated temperature and radiation conditions. Whole container thermal aging studies followed by helium leakage testing and compression set measurements were used to establish an estimate for a failure criterion for O-ring compression set of ≥65 %. The whole container aging studies further show that the air flow and efficiency functions of the filter do not degrade significantly after thermal aging. However, the degradation of the water-resistant function leads to water penetration failure after four months at 210°C, but does not cause failure after 10 months at 120°C (130°C is the maximum operating temperature for the PTFE membrane). The thermal aging data for O-ring compression set do not meet the assumptions of standard time-temperature superposition analysis for accelerated aging studies. Instead, the data suggest that multiple degradation mechanisms are operative, with a reversible mechanism operative at low aging temperatures and an irreversible mechanism dominating at high aging temperatures. To distinguish between these mechanisms, we have measured compression set after allowing the sample to physically relax, thereby minimizing the effect of the reversible mechanism. The resulting data were analyzed using two distinct mathematical methods to obtain a lifetime estimate based on chemical degradation alone. Both methods support a lifetime estimate of greater than 150 years at 80°C. Although the role of the reversible mechanism is not fully understood, it is clear that the contribution to the total compression set is small in comparison to that due to the chemical degradation mechanism. To better understand the chemical degradation mechanism, thermally aged O-ring samples have been characterized by Fourier Transform Infrared (FTIR), Electron Paramagnetic Resonance (EPR), Gel Permeation Chromatography (GPC

  18. Right Diaphragm Spontaneous Rupture: A Surgical Approach

    Directory of Open Access Journals (Sweden)

    Duilio Divisi

    2011-01-01

    Full Text Available We present a case of spontaneous rupture of the diaphragm, characterized by nonspecific symptoms. The rapid diagnosis and appropriate surgical approach led to a positive resolution of the pathology.

  19. Spontaneous cecal perforation secondary to acute fulminant ...

    African Journals Online (AJOL)

    Spontaneous cecal perforation secondary to acute fulminant gastroenteritis: report of a rare case. Duvuru Ram, Vilvapathy S. Karthikeyan, Sarath C. Sistla, Sheik M. Ali, Parnandi Sridhar, Nagarajan Rajkumar ...

  20. Spontaneous Trait Inferences on Social Media.

    Science.gov (United States)

    Levordashka, Ana; Utz, Sonja

    2017-01-01

    The present research investigates whether spontaneous trait inferences occur under conditions characteristic of social media and networking sites: nonextreme, ostensibly self-generated content, simultaneous presentation of multiple cues, and self-paced browsing. We used an established measure of trait inferences (false recognition paradigm) and a direct assessment of impressions. Without being asked to do so, participants spontaneously formed impressions of people whose status updates they saw. Our results suggest that trait inferences occurred from nonextreme self-generated content, which is commonly found in social media updates (Experiment 1) and when nine status updates from different people were presented in parallel (Experiment 2). Although inferences did occur during free browsing, the results suggest that participants did not necessarily associate the traits with the corresponding status update authors (Experiment 3). Overall, the findings suggest that spontaneous trait inferences occur on social media. We discuss implications for online communication and research on spontaneous trait inferences.

  1. Spontane abdominale arteriovenøse fistler

    DEFF Research Database (Denmark)

    Flarup, S; Lindholt, Jes Sanddal

    1997-01-01

    Spontaneous arteriovenous fistulas between major abdominal vessels (AAVF) complicates about 1% of abdominal aortic aneurysms. AAVF produces severe circulatory disturbances with high operative mortality. Preoperative diagnosis is important but difficult due to the varied nature of presentation. Fo...

  2. Accelerated Lifetime Testing Methodology for Lifetime Estimation of Lithium-ion Batteries used in Augmented Wind Power Plants

    DEFF Research Database (Denmark)

    Stroe, Daniel Ioan; Swierczynski, Maciej Jozef; Stan, Ana-Irina

    2014-01-01

    The development of lifetime estimation models for Lithium-ion battery cells, which are working under highly variable mission profiles characteristic for wind power plant applications, requires a lot of expenditures and time resources. Therefore, batteries have to be tested under accelerated...... lifetime ageing conditions. This paper presents a three-stage methodology used for accelerated lifetime testing of Lithium ion batteries. The results obtained at the end of the accelerated ageing process were used for the parametrization of a performance-degradation lifetime model, which is able to predict...... was validated by running a verification stage of the lifetime model, where Lithium-ion battery cells were tested at normal operating conditions using an application specific mission profile....

  3. Depressive disorder and grief following spontaneous abortion.

    Science.gov (United States)

    Kulathilaka, Susil; Hanwella, Raveen; de Silva, Varuni A

    2016-04-12

    Abortion is associated with moderate to high risk of psychological problems such as depression, use of alcohol or marijuana, anxiety, depression and suicidal behaviours. The increased risk of depression after spontaneous abortion in Asian populations has not been clearly established. Only a few studies have explored the relationship between grief and depression after abortion. A study was conducted to assess the prevalence and risk factors of depressive disorder and complicated grief among women 6-10 weeks after spontaneous abortion and compare the risk of depression with pregnant women attending an antenatal clinic. Spontaneous abortion group consisted of women diagnosed with spontaneous abortion by a Consultant Obstetrician. Women with confirmed or suspected induced abortion were excluded. The comparison group consisted of randomly selected pregnant, females attending the antenatal clinics of the two hospitals. Diagnosis of depressive disorder was made according to ICD-10 clinical criteria based on a structured clinical interview. This assessment was conducted in both groups. The severity of depressive symptoms were assessed using the Patients Health Questionnaire (PHQ-9). Grief was assessed using the Perinatal Grief Scale which was administered to the women who had experienced spontaneous abortion. The sample consisted of 137 women in each group. The spontaneous abortion group (mean age 30.39 years (SD = 6.38) were significantly older than the comparison group (mean age 28.79 years (SD = 6.26)). There were more females with ≥10 years of education in the spontaneous abortion group (n = 54; SD = 39.4) compared to the comparison group (n = 37; SD = 27.0). The prevalence of depression in the spontaneous abortion group was 18.6 % (95 CI, 11.51-25.77). The prevalence of depression in the comparison group was 9.5 % (95 CI, 4.52-14.46). Of the 64 women fulfilling criteria for grief, 17 (26.6 %) also fulfilled criteria for a depressive episode. The relative risk of

  4. Postmenopausal spontaneous uterine perforation: Case report

    Science.gov (United States)

    İşlek Seçen, Elçin; Ağış, Hilal; Altunkaya, Canan; Avşar, Ayşe Filiz

    2015-01-01

    Spontaneous uterine rupture and generalized peritonitis caused by pyometra occurs rarely with high morbidity and mortality. A correct and definite diagnosis can be made with laparotomy or laparoscopy. The clinical findings of perforated pyometra are similar to perforation of the gastrointestinal tract and gynecologic symptoms are less frequent, which makes preoperative diagnosis difficult. We report a case of a patient aged 82 years who underwent surgery for spontaneous uterine rupture and generalized peritonitis as a result of pyometra. PMID:28913055

  5. Endometriosis-related spontaneous diaphragmatic rupture.

    Science.gov (United States)

    Triponez, Frédéric; Alifano, Marco; Bobbio, Antonio; Regnard, Jean-François

    2010-10-01

    Non-traumatic, spontaneous diaphragmatic rupture is a rare event whose pathophysiology is not known. We report the case of endometriosis-related spontaneous rupture of the right diaphragm with intrathoracic herniation of the liver, gallbladder and colon. We hypothesize that the invasiveness of endometriotic tissue caused diaphragm fragility, which finally lead to its complete rupture without traumatic event. The treatment consisted of a classical management of diaphragmatic rupture, with excision of the endometriotic nodule followed by medical ovarian suppression for six months.

  6. Spontaneous regression of metastatic Merkel cell carcinoma.

    LENUS (Irish Health Repository)

    Hassan, S J

    2010-01-01

    Merkel cell carcinoma is a rare aggressive neuroendocrine carcinoma of the skin predominantly affecting elderly Caucasians. It has a high rate of local recurrence and regional lymph node metastases. It is associated with a poor prognosis. Complete spontaneous regression of Merkel cell carcinoma has been reported but is a poorly understood phenomenon. Here we present a case of complete spontaneous regression of metastatic Merkel cell carcinoma demonstrating a markedly different pattern of events from those previously published.

  7. Spontaneous intracranial epidural hematoma during rivaroxaban treatment

    Energy Technology Data Exchange (ETDEWEB)

    Ruschel, Leonardo Gilmone; Rego, Felipe Marques Monteiro do; Milano, Jeronimo Buzetti; Jung, Gustavo Simiano; Silva Junior, Luis Fernando; Ramina, Ricardo, E-mail: leonardoruschel@yahoo.com.br [Instituto de Neurologia de Curitiba (INC), Curitiba, PR (Brazil)

    2016-11-15

    According to our research, this is the first case described in the literature of spontaneous intracranial epidural hematoma secondary to the use of Xarelto®. Spontaneous intracranial epidural hematomas are rarely described in the literature. They are associated with infectious diseases of the skull, coagulation disorders, vascular malformations of the dura mater and metastasis to the skull. Long-term post-marketing monitoring and independent reports will probably detect the full spectrum of hemorrhagic complications of the use of rivaroxaban. (author)

  8. Spontaneous intracranial epidural hematoma during rivaroxaban treatment.

    Science.gov (United States)

    Ruschel, Leonardo Gilmone; Rego, Felipe Marques Monteiro do; Milano, Jerônimo Buzetti; Jung, Gustavo Simiano; Silva, Luis Fernando; Ramina, Ricardo

    2016-11-01

    According to our research, this is the first case described in the literature of spontaneous intracranial epidural hematoma secondary to the use of Xareltor. Spontaneous intracranial epidural hematomas are rarely described in the literature. They are associated with infectious diseases of the skull, coagulation disorders, vascular malformations of the dura mater and metastasis to the skull. Long-term post-marketing monitoring and independent reports will probably detect the full spectrum of hemorrhagic complications of the use of rivaroxaban.

  9. Spontaneous Pneumothoraces in Patients with Birt-Hogg-Dubé Syndrome.

    Science.gov (United States)

    Gupta, Nishant; Kopras, Elizabeth J; Henske, Elizabeth P; James, Laura E; El-Chemaly, Souheil; Veeraraghavan, Srihari; Drake, Matthew G; McCormack, Francis X

    2017-05-01

    Spontaneous pneumothorax is a common complication of Birt-Hogg-Dubé syndrome (BHD). The optimal approach to treatment and prevention of BHD-associated spontaneous pneumothorax, and to advising patients with BHD regarding risk of pneumothorax associated with air travel, is not well established. Patients with BHD were recruited from the Rare Lung Diseases Clinic Network and the BHD Foundation and surveyed about disease manifestations and air travel experiences. A total of 104 patients completed the survey. The average age at diagnosis was 47 years, with an average delay from first symptoms of 13 years. Pulmonary cysts were the most frequent phenotypic manifestation of BHD, present in 85% of patients. Spontaneous pneumothorax was the presenting manifestation that led to the diagnosis of BHD in 65% of patients, typically after the second episode (mean, 2.4 episodes). Seventy-nine (76%) of 104 patients had at least one spontaneous pneumothorax during their lifetime, and 82% had multiple pneumothoraces. Among patients with multiple pneumothoraces, 73% had an ipsilateral recurrence, and 48% had a subsequent contralateral spontaneous pneumothorax following a sentinel event. The mean ages at first and second pneumothoraces were 36.5 years (range, 14-63 yr) and 37 years (range, 20-55 yr), respectively. The average number of spontaneous pneumothoraces experienced by patients with a sentinel pneumothorax was 3.6. Pleurodesis was generally performed after the second (mean, 2.4) ipsilateral pneumothorax and reduced the ipsilateral recurrence rate by half. A total of 11 episodes of spontaneous pneumothorax occurred among eight patients either during or within the 24-hour period following air travel, consistent with an air travel-related pneumothorax rate of 8% per patient and 0.12% per flight. Prior pleurodesis reduced the occurrence of a subsequent flight-related pneumothorax. Spontaneous pneumothorax is an important, recurrent manifestation of pulmonary involvement in patients

  10. FEL gain optimisation and spontaneous radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bali, L.M.; Srivastava, A.; Pandya, T.P. [Lucknow Univ. (India)] [and others

    1995-12-31

    Colson have evaluated FEL gains for small deviations from perfect electron beam injection, with radiation of the same polarisation as that of the wiggler fields. We find that for optimum gain the polarisation of the optical field should be the same as that of the spontaneous emission under these conditions. With a helical wiggler the axial oscillations resulting from small departures from perfect electron beam injection lead to injection dependent unequal amplitudes and phases of the spontaneous radiation in the two transverse directions. Viewed along the axis therefore the spontaneous emission is elliptically polarised. The azimuth of the ellipse varies with the difference of phase of the two transverse components of spontaneous emission but the eccentricity remains the same. With planar wigglers the spontaneous emission viewed in the axial direction is linearly polarised, again with an injection dependent azimuth. For optimum coherent gain of a radiation field its polarisation characteristics must be the same as those of the spontaneous radiation with both types of wiggler. Thus, with a helical wiggler and the data reported earlier, an increase of 10% in the FEL gain at the fundamental frequency and of 11% at the fifth harmonic has been calculated in the small gain per pass limit. Larger enhancements in gain may result from more favourable values of input parameters.

  11. Lifetime and Path Length of the Virtual Particle

    International Nuclear Information System (INIS)

    Lyuboshitz, V.L.; Lyuboshitz, V.V.

    2005-01-01

    The concepts of the lifetime and path length of a virtual particle are introduced. It is shown that, near the mass surface of the real particle, these quantities constitute a 4-vector. At very high energies, the virtual particle can propagate over considerable (even macroscopic) distances. The formulas for the lifetime and path length of an ultrarelativistic virtual electron in the process of bremsstrahlung in the Coulomb field of a nucleus are obtained. The lifetime and path length of the virtual photon at its conversion into an electron-positron pair are discussed. The connection between the path length of the virtual particle and the coherence length (formation length) is analyzed

  12. A study of lifetime within the -12 sec range

    International Nuclear Information System (INIS)

    Dorobantu, V.

    1977-01-01

    Lifetimes of excited nuclear states are studied with a particular emphasis on the determination of nuclear lifetimes by means of the Doppler shift decomposition attenuation method - DSAM - which is based on the mathematical theory of stochastic processes; by its own nature, the emission of recoil nuclei, their motion through an amorphous medium and the detection of gamma rays resulting from these nuclei are all stochastic processes as well. Measurements of lifetimes together with other measurements can supply nuclear structure data, as well as information on the slowing-down process of an energetic ion through a certain material. The experimental tests have been carried out on the Tandem accelerator - IFIN, Bucharest. (author)

  13. Measurement of the Bs0 Lifetime Using Semileptonic Decays

    Science.gov (United States)

    Abazov, V. M.; Abbott, B.; Abolins, M.; Acharya, B. S.; Adams, M.; Adams, T.; Agelou, M.; Agram, J.-L.; Ahn, S. H.; Ahsan, M.; Alexeev, G. D.; Alkhazov, G.; Alton, A.; Alverson, G.; Alves, G. A.; Anastasoaie, M.; Andeen, T.; Anderson, S.; Andrieu, B.; Anzelc, M. S.; Arnoud, Y.; Arov, M.; Askew, A.; Åsman, B.; Jesus, A. C. S. Assis; Atramentov, O.; Autermann, C.; Avila, C.; Ay, C.; Badaud, F.; Baden, A.; Bagby, L.; Baldin, B.; Bandurin, D. V.; Banerjee, P.; Banerjee, S.; Barberis, E.; Bargassa, P.; Baringer, P.; Barnes, C.; Barreto, J.; Bartlett, J. F.; Bassler, U.; Bauer, D.; Bean, A.; Begalli, M.; Begel, M.; Belanger-Champagne, C.; Bellavance, A.; Benitez, J. A.; Beri, S. B.; Bernardi, G.; Bernhard, R.; Berntzon, L.; Bertram, I.; Besançon, M.; Beuselinck, R.; Bezzubov, V. A.; Bhat, P. C.; Bhatnagar, V.; Binder, M.; Biscarat, C.; Black, K. M.; Blackler, I.; Blazey, G.; Blekman, F.; Blessing, S.; Bloch, D.; Bloom, K.; Blumenschein, U.; Boehnlein, A.; Boeriu, O.; Bolton, T. A.; Borcherding, F.; Borissov, G.; Bos, K.; Bose, T.; Brandt, A.; Brock, R.; Brooijmans, G.; Bross, A.; Brown, D.; Buchanan, N. J.; Buchholz, D.; Buehler, M.; Buescher, V.; Burdin, S.; Burke, S.; Burnett, T. H.; Busato, E.; Buszello, C. P.; Butler, J. M.; Calvet, S.; Cammin, J.; Caron, S.; Carrasco-Lizarraga, M. A.; Carvalho, W.; Casey, B. C. K.; Cason, N. M.; Castilla-Valdez, H.; Chakrabarti, S.; Chakraborty, D.; Chan, K. M.; Chandra, A.; Chapin, D.; Charles, F.; Cheu, E.; Chevallier, F.; Cho, D. K.; Choi, S.; Choudhary, B.; Christofek, L.; Claes, D.; Clément, B.; Clément, C.; Coadou, Y.; Cooke, M.; Cooper, W. E.; Coppage, D.; Corcoran, M.; Cousinou, M.-C.; Cox, B.; Crépé-Renaudin, S.; Cutts, D.; Ćwiok, M.; da Motta, H.; Das, A.; Das, M.; Davies, B.; Davies, G.; Davis, G. A.; de, K.; de Jong, P.; de Jong, S. J.; de La Cruz-Burelo, E.; Martins, C. De Oliveira; Degenhardt, J. D.; Déliot, F.; Demarteau, M.; Demina, R.; Demine, P.; Denisov, D.; Denisov, S. P.; Desai, S.; Diehl, H. T.; Diesburg, M.; Doidge, M.; Dominguez, A.; Dong, H.; Dudko, L. V.; Duflot, L.; Dugad, S. R.; Duperrin, A.; Dyer, J.; Dyshkant, A.; Eads, M.; Edmunds, D.; Edwards, T.; Ellison, J.; Elmsheuser, J.; Elvira, V. D.; Eno, S.; Ermolov, P.; Estrada, J.; Evans, H.; Evdokimov, A.; Evdokimov, V. N.; Fatakia, S. N.; Feligioni, L.; Ferapontov, A. V.; Ferbel, T.; Fiedler, F.; Filthaut, F.; Fisher, W.; Fisk, H. E.; Fleck, I.; Ford, M.; Fortner, M.; Fox, H.; Fu, S.; Fuess, S.; Gadfort, T.; Galea, C. F.; Gallas, E.; Galyaev, E.; Garcia, C.; Garcia-Bellido, A.; Gardner, J.; Gavrilov, V.; Gay, A.; Gay, P.; Gelé, D.; Gelhaus, R.; Gerber, C. E.; Gershtein, Y.; Gillberg, D.; Ginther, G.; Gollub, N.; Gómez, B.; Gounder, K.; Goussiou, A.; Grannis, P. D.; Greenlee, H.; Greenwood, Z. D.; Gregores, E. M.; Grenier, G.; Gris, Ph.; Grivaz, J.-F.; Grünendahl, S.; Grünewald, M. W.; Guo, F.; Guo, J.; Gutierrez, G.; Gutierrez, P.; Haas, A.; Hadley, N. J.; Haefner, P.; Hagopian, S.; Haley, J.; Hall, I.; Hall, R. E.; Han, L.; Hanagaki, K.; Harder, K.; Harel, A.; Harrington, R.; Hauptman, J. M.; Hauser, R.; Hays, J.; Hebbeker, T.; Hedin, D.; Hegeman, J. G.; Heinmiller, J. M.; Heinson, A. P.; Heintz, U.; Hensel, C.; Hesketh, G.; Hildreth, M. D.; Hirosky, R.; Hobbs, J. D.; Hoeneisen, B.; Hohlfeld, M.; Hong, S. J.; Hooper, R.; Houben, P.; Hu, Y.; Hynek, V.; Iashvili, I.; Illingworth, R.; Ito, A. S.; Jabeen, S.; Jaffré, M.; Jain, S.; Jakobs, K.; Jarvis, C.; Jenkins, A.; Jesik, R.; Johns, K.; Johnson, C.; Johnson, M.; Jonckheere, A.; Jonsson, P.; Juste, A.; Käfer, D.; Kahn, S.; Kajfasz, E.; Kalinin, A. M.; Kalk, J. M.; Kalk, J. R.; Kappler, S.; Karmanov, D.; Kasper, J.; Katsanos, I.; Kau, D.; Kaur, R.; Kehoe, R.; Kermiche, S.; Kesisoglou, S.; Khanov, A.; Kharchilava, A.; Kharzheev, Y. M.; Khatidze, D.; Kim, H.; Kim, T. J.; Kirby, M. H.; Klima, B.; Kohli, J. M.; Konrath, J.-P.; Kopal, M.; Korablev, V. M.; Kotcher, J.; Kothari, B.; Koubarovsky, A.; Kozelov, A. V.; Kozminski, J.; Kryemadhi, A.; Krzywdzinski, S.; Kuhl, T.; Kumar, A.; Kunori, S.; Kupco, A.; Kurča, T.; Kvita, J.; Lager, S.; Lammers, S.; Landsberg, G.; Lazoflores, J.; Bihan, A.-C. Le; Lebrun, P.; Lee, W. M.; Leflat, A.; Lehner, F.; Leonidopoulos, C.; Lesne, V.; Leveque, J.; Lewis, P.; Li, J.; Li, Q. Z.; Lima, J. G. R.; Lincoln, D.; Linnemann, J.; Lipaev, V. V.; Lipton, R.; Liu, Z.; Lobo, L.; Lobodenko, A.; Lokajicek, M.; Lounis, A.; Love, P.; Lubatti, H. J.; Lynker, M.; Lyon, A. L.; Maciel, A. K. A.; Madaras, R. J.; Mättig, P.; Magass, C.; Magerkurth, A.; Magnan, A.-M.; Makovec, N.; Mal, P. K.; Malbouisson, H. B.; Malik, S.; Malyshev, V. L.; Mao, H. S.; Maravin, Y.; Martens, M.; Mattingly, S. E. K.; McCarthy, R.; McCroskey, R.; Meder, D.; Melnitchouk, A.; Mendes, A.; Mendoza, L.; Merkin, M.; Merritt, K. W.; Meyer, A.; Meyer, J.; Michaut, M.

    2006-12-01

    We report a measurement of the Bs0 lifetime in the semileptonic decay channel Bs0→Ds-μ+νX (and its charge conjugate), using approximately 0.4fb-1 of data collected with the D0 detector during 2002 2004. Using 5176 reconstructed Ds-μ+ signal events, we have measured the Bs0 lifetime to be τ(Bs0)=1.398±0.044(stat)-0.025+0.028(syst)ps. This is the most precise measurement of the Bs0 lifetime to date.

  14. Positron Lifetimes in Pure and Doped Ice and in Water

    DEFF Research Database (Denmark)

    Eldrup, Morten Mostgaard; Mogensen, O.; Trumpy, Georg

    1972-01-01

    Positron lifetime spectra were measured in mono- and polycrystalline light ice, polycrystalline heavy ice, doped light ice, as well as in light and heavy water. All spectra were resolved into three components. At temperatures between −196° and −100°C the lifetimes and relative intensities...... for the other components show a complex behavior. The spectra for mono- and polycrystalline light ice and for polycrystalline heavy ice are identical. For water long lifetime components attributed to ortho-Ps are 1.86 nsec, 27% for H2O and 2.01 nsec, 22% for D2O. Theoretical explanations are suggested. Fast...

  15. Measurement of the b hadron lifetime with the dipole method

    Science.gov (United States)

    Buskulic, D.; de Bonis, I.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Minard, M.-N.; Pietrzyk, B.; Ariztizabal, F.; Comas, P.; Crespo, J. M.; Delfino, M.; Efthymiopoulos, I.; Fernandez, E.; Fernandez-Bosman, M.; Gaitan, V.; Garrido, Ll.; Mattison, T.; Pacheco, A.; Padilla, C.; Pascual, A.; Creanza, D.; de Palma, M.; Farilla, A.; Iaselli, G.; Maggi, G.; Marinelli, N.; Natali, S.; Nuzzo, S.; Ranieri, A.; Raso, G.; Romano, F.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Zito, G.; Chai, Y.; Hu, H.; Huang, D.; Huang, X.; Lin, J.; Wang, T.; Xie, Y.; Xu, D.; Xu, R.; Zhang, J.; Zhang, L.; Zhao, W.; Bonvicini, G.; Boudreau, J.; Casper, D.; Drevermann, H.; Forty, R. W.; Ganis, G.; Gay, C.; Hagelberg, R.; Harvey, J.; Hilgart, J.; Jacobsen, R.; Jost, B.; Knobloch, J.; Lehraus, I.; Maggi, M.; Markou, C.; Martinez, M.; Mato, P.; Meinhard, H.; Minten, A.; Miquel, R.; Moser, H.-G.; Palazzi, P.; Pater, J. R.; Perlas, J. A.; Pusztaszeri, J.-F.; Ranjard, F.; Rolandi, L.; Rothberg, J.; Ruan, T.; Saich, M.; Schlatter, D.; Schmelling, M.; Sefkow, F.; Tejessy, W.; Tomalin, I. R.; Veenhof, R.; Wachsmuth, H.; Wasserbaech, S.; Wiedenmann, W.; Wildish, T.; Witzeling, W.; Wotschack, J.; Ajaltouni, Z.; Badaud, F.; Bardadin-Otwinowska, M.; El Fellous, R.; Falvard, A.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Prulhière, F.; Saadi, F.; Fearnley, T.; Hansen, J. B.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Møllerud, R.; Nilsson, B. S.; Kyriakis, A.; Simopoulou, E.; Siotis, I.; Vayaki, A.; Zachariadou, K.; Badier, J.; Blondel, A.; Bonneaud, G.; Brient, J. C.; Bourdon, P.; Fouque, G.; Orteu, S.; Rougé, A.; Rumpf, M.; Tanaka, R.; Verderi, M.; Videau, H.; Candlin, D. J.; Parsons, M. I.; Veitch, E.; Focardi, E.; Moneta, L.; Parrini, G.; Corden, M.; Georgiopoulos, C.; Ikeda, M.; Levinthal, D.; Antonelli, A.; Baldini, R.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Cerutti, F.; Chiarella, V.; D'Ettorre-Piazzoli, B.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Passalacqua, L.; Pepe-Altarelli, M.; Picchi, P.; Colrain, P.; Ten Have, I.; Lynch, J. G.; Maitland, W.; Morton, W. T.; Raine, C.; Reeves, P.; Scarr, J. M.; Smith, K.; Smith, M. G.; Thompson, A. S.; Turnbull, R. M.; Brandl, B.; Braun, O.; Geweniger, C.; Hanke, P.; Hepp, V.; Kluge, E. E.; Maumary, Y.; Putzer, A.; Rensch, B.; Stahl, A.; Tittel, K.; Wunsch, M.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Cattaneo, M.; Colling, D. J.; Dornan, P. J.; Greene, A. M.; Hassard, J. F.; Lieske, N. M.; Moutoussi, A.; Nash, J.; Patton, S.; Payne, D. G.; Phillips, M. J.; San Martin, G.; Sedgbeer, J. K.; Wright, A. G.; Girtler, P.; Kuhn, D.; Rudolph, G.; Vogl, R.; Bowdery, C. K.; Brodbeck, T. J.; Finch, A. J.; Foster, F.; Hughes, G.; Jackson, D.; Keemer, N. R.; Nuttall, M.; Patel, A.; Sloan, T.; Snow, S. W.; Whelan, E. P.; Kleinknecht, K.; Raab, J.; Renk, B.; Sander, H.-G.; Schmidt, H.; Walther, S. M.; Wanke, R.; Wolf, B.; Zimmermann, A.; Bencheikh, A. M.; Benchouk, C.; Bonissent, A.; Carr, J.; Coyle, P.; Drinkard, J.; Etienne, F.; Nicod, D.; Papalexiou, S.; Payre, P.; Roos, L.; Rousseau, D.; Schwemling, P.; Talby, M.; Adlung, S.; Assmann, R.; Bauer, C.; Blum, W.; Brown, D.; Cattaneo, P.; Dehning, B.; Dietl, H.; Dydak, F.; Frank, M.; Halley, A. W.; Jakobs, K.; Lauber, J.; Lütjens, G.; Lutz, G.; Männer, W.; Richter, R.; Schröder, J.; Schwarz, A. S.; Settles, R.; Seywerd, H.; Stierlin, U.; Stiegler, U.; St. Denis, R.; Wolf, G.; Alemany, R.; Boucrot, J.; Callot, O.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Jaffe, D. E.; Janot, P.; Kim, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Schune, M.-H.; Veillet, J.-J.; Videau, I.; Zhang, Z.; Abbaneo, D.; Bagliesi, G.; Batignani, G.; Bottigli, U.; Bozzi, C.; Calderini, G.; Carpinelli, M.; Ciocci, M. A.; Ciulli, V.; Dell'Orso, R.; Ferrante, I.; Fidecaro, F.; Foà, L.; Forti, F.; Giassi, A.; Giorgi, M. A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Mannelli, E. B.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Rizzo, G.; Sanguinetti, G.; Spagnolo, P.; Steinberger, J.; Tenchini, R.; Tonelli, G.; Triggiani, G.; Valassi, A.; Vannini, C.; Venturi, A.; Verdini, P. G.; Walsh, J.; Betteridge, A. P.; Gao, Y.; Green, M. G.; March, P. V.; Mir, Ll. M.; Medcalf, T.; Quazi, I. S.; Strong, J. A.; West, L. R.; Botterill, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Norton, P. R.; Thompson, J. C.; Bloch-Devaux, B.; Colas, P.; Duarte, H.; Emery, S.; Kozanecki, W.; Lançon, E.; Lemaire, M. C.; Locci, E.; Marx, B.; Perez, P.; Rander, J.; Renardy, J.-F.; Rosowsky, A.; Roussarie, A.; Schuller, J.-P.; Schwindling, J.; Si Mohand, D.; Vallage, B.; Johnson, R. P.; Litke, A. M.; Taylor, G.; Wear, J.; Ashman, J. G.; Babbage, W.; Booth, C. N.; Buttar, C.; Cartwright, S.; Combley, F.; Dawson, I.; Thompson, L. F.; Barbeiro, E.; Böhrer, A.; Brandt, S.; Cowan, G.; Grupen, C.; Lutters, G.; Rivera, F.; Schäfer, U.; Smolik, L.; Bosisio, L.; Della Marina, R.; Giannini, G.; Gobbo, B.; Ragusa, F.; Bellantoni, L.; Chen, W.; Conway, J. S.; Feng, Z.; Ferguson, D. P. S.; Gao, Y. S.; Grahl, J.; Harton, J. L.; Hayes, O. J.; Nachtman, J. M.; Pan, Y. B.; Saadi, Y.; Schmitt, M.; Scott, I.; Sharma, V.; Shi, Z. H.; Turk, J. D.; Walsh, A. M.; Weber, F. V.; Sau Lan Wu; Wu, X.; Zheng, M.; Zobernig, G.; Aleph Collaboration

    1993-09-01

    A measurement of the average lifetime of b hadrons has been performed with dipole method on a sample of 260 000 hadronic Z decays recorded with the ALEPH detector during 1991. The dipole is the distance between the vertices built in the opposite hemispheres. The mean dipole is extracted from all the events without attempting b enrichment. Comparing the average of the data dipole distribution with a Monte Carlo calibration curve obtained with different b lifetimes, an average b hadron lifetime of 1.51±0.08 ps is extracted.

  16. Positron lifetime study of neutron-irradiated molybdenum

    International Nuclear Information System (INIS)

    Hinode, Kenji; Tanigawa, Shoichiro; Kumakura, Hiroaki; Doyama, Masao; Shiraishi, Kensuke.

    1978-01-01

    Annealing behavior of fast-neutron-irradiated molybdenum was studied by means of positron lifetime technique. It was found that Stage III annealing can be mainly identified as the vacancy migration process from the detailed analyses of data. The void growth after successive high temperature annealings was clearly detected through the changes of positron lifetime parameters. An attempt to analyse the size distribution of voids from positron lifetime spectra was presented, and discussions on the evaluation of void concentration from positron data are also given. (author)

  17. A lifetime prediction method for LEDs considering mission profiles

    DEFF Research Database (Denmark)

    Qu, Xiaohui; Wang, Huai; Zhan, Xiaoqing

    2016-01-01

    and to benchmark the cost-competitiveness of different lighting technologies. The existing lifetime data released by LED manufacturers or standard organizations are usually applicable only for specific temperature and current levels. Significant lifetime discrepancies may be observed in field operations due...... to the varying operational and environmental conditions during the entire service time (i.e., mission profiles). To overcome the challenge, this paper proposes an advanced lifetime prediction method, which takes into account the field operation mission profiles and the statistical properties of the life data...

  18. A Lifetime Prediction Method for LEDs Considering Real Mission Profiles

    DEFF Research Database (Denmark)

    Qu, Xiaohui; Wang, Huai; Zhan, Xiaoqing

    2017-01-01

    and to benchmark the cost-competitiveness of different lighting technologies. However, the existing lifetime data released by LED manufacturers or standard organizations are usually applicable only for some specific temperature and current levels. Significant lifetime discrepancies may be seen in the field...... operations due to the varying operational and environmental conditions during the entire service time (i.e., mission profiles). To overcome the challenge, this paper proposes an advanced lifetime prediction method, which takes into account the field operation mission profiles and also the statistical...

  19. Study of variables for accelerating lifetime testing of SOFCs

    DEFF Research Database (Denmark)

    Ploner, Alexandra; Hagen, Anke; Hauch, Anne

    Solid oxide fuel cell (SOFC) applications require lifetimes of several years on the system level. A big challenge is to proof/confirm/demonstrate such exceptionally long lifetimes.Accelerated or compressed testing are possible methods. Activities in this area have been carried out without arriving...... at different current load cycling profiles revealed a strong deviation between predicted and measured lifetime [3].In this study, we present a detailed analysis of durability results for degradation mechanisms of single SOFC components as function of operating conditions. Electrochemical impedance data...

  20. Modeling and optimization of membrane lifetime in dead-end ultra filtration

    NARCIS (Netherlands)

    Zondervan, Edwin; Roffel, Brian

    2008-01-01

    In this paper, a membrane lifetime model is developed and experimentally validated. The lifetime model is based on the Weibull probability density function. The lifetime model can be used to determine an unambiguous characteristic membrane lifetime. Experimental results showed that membrane lifetime

  1. Dependence of InGaN solar cell performance on polarization-induced electric field and carrier lifetime

    International Nuclear Information System (INIS)

    Yang Jing; Zhao De-Gang; Jiang De-Sheng; Liu Zong-Shun; Chen Ping; Li Liang; Wu Liang-Liang; Le Ling-Cong; Li Xiao-Jing; He Xiao-Guang; Yang Hui; Wang Hui; Zhu Jian-Jun; Zhang Shu-Ming; Zhang Bao-Shun

    2013-01-01

    The effects of Mg-induced net acceptor doping concentration and carrier lifetime on the performance of a p—i—n InGaN solar cell are investigated. It is found that the electric field induced by spontaneous and piezoelectric polarization in the i-region could be totally shielded when the Mg-induced net acceptor doping concentration is sufficiently high. The polarization-induced potential barriers are reduced and the short circuit current density is remarkably increased from 0.21 mA/cm 2 to 0.95 mA/cm 2 by elevating the Mg doping concentration. The carrier lifetime determined by defect density of i-InGaN also plays an important role in determining the photovoltaic properties of solar cell. The short circuit current density severely degrades, and the performance of InGaN solar cell becomes more sensitive to the polarization when carrier lifetime is lower than the transit time. This study demonstrates that the crystal quality of InGaN absorption layer is one of the most important challenges in realizing high efficiency InGaN solar cells. (interdisciplinary physics and related areas of science and technology)

  2. Clinical results of fluorescence lifetime imaging in ophthalmology

    Science.gov (United States)

    Schweitzer, D.; Quick, S.; Klemm, M.; Hammer, M.; Jentsch, S.; Dawczynski, J.; Becker, W.

    2009-07-01

    A laser scanner ophthalmoscope was developed for in vivo fluorescence lifetime measurements at the human retina. Measurements were performed in 30 degree fundus images. The fundus was excited by pulses of 75 ps (FWHM). The dynamic fluorescence was detected in two spectral channels K1(490-560nm), K2(560-700 nm) by time-correlated single photon counting. The decay of fluorescence was three-exponentially. Local and global alterations in lifetimes were found between healthy subjects and patients suffering from age-related macular degeneration, diabetic retinopathy, and vessel occlusion. The lifetimes T1, T2, and T3 in both channels are changed to longer values in AMD and diabetic retinopathy in comparison with healthy subjects. The lifetime T2 in K1 is most sensitive to metabolic alterations in branch arterial vessel occlusion.

  3. Positron lifetime calculation for the elements of the periodic table.

    Science.gov (United States)

    Campillo Robles, J M; Ogando, E; Plazaola, F

    2007-04-30

    Theoretical positron lifetime values have been calculated systematically for most of the elements of the periodic table. Self-consistent and non-self-consistent schemes have been used for the calculation of the electronic structure in the solid, as well as different parametrizations for the positron enhancement factor and correlation energy. The results obtained have been studied and compared with experimental data, confirming the theoretical trends. As is known, positron lifetimes in bulk show a periodic behaviour with atomic number. These calculations also confirm that monovacancy lifetimes follow the same behaviour. The effects of enhancement factors used in calculations have been commented upon. Finally, we have analysed the effects that f and d electrons have on positron lifetimes.

  4. Positron lifetime calculation for the elements of the periodic table

    International Nuclear Information System (INIS)

    Robles, J M Campillo; Ogando, E; Plazaola, F

    2007-01-01

    Theoretical positron lifetime values have been calculated systematically for most of the elements of the periodic table. Self-consistent and non-self-consistent schemes have been used for the calculation of the electronic structure in the solid, as well as different parametrizations for the positron enhancement factor and correlation energy. The results obtained have been studied and compared with experimental data, confirming the theoretical trends. As is known, positron lifetimes in bulk show a periodic behaviour with atomic number. These calculations also confirm that monovacancy lifetimes follow the same behaviour. The effects of enhancement factors used in calculations have been commented upon. Finally, we have analysed the effects that f and d electrons have on positron lifetimes

  5. DC photogun vacuum characterization through photocathode lifetime studies

    Energy Technology Data Exchange (ETDEWEB)

    Marcy Stutzman; Joseph Grames; Matt Poelker; Kenneth Surles-Law; Philip Adderley

    2007-07-02

    Excellent vacuum is essential for long photocathode lifetimes in DC high voltage photoelectron guns. Vacuum Research at Thomas Jefferson National Accelerator Facility has focused on characterizing the existing vacuum systems at the CEBAF polarized photoinjector and on quantifying improvements for new systems. Vacuum chamber preprocessing, full activation of NEG pumps and NEG coating the chamber walls should improve the vacuum within the electron gun, however, pressure measurement is difficult at pressures approaching the extreme-high-vacuum (XHV) region and extractor gauge readings are not significantly different between the improved and original systems. The ultimate test of vacuum in a DC high voltage photogun is the photocathode lifetime, which is limited by the ionization and back-bombardment of residual gasses. Discussion will include our new load-locked gun design as well as lifetime measurements in both our operational and new photo-guns, and the correlations between measured vacuum and lifetimes will be investigated.

  6. Improving, characterizing and predicting the lifetime of organic photovoltaics

    DEFF Research Database (Denmark)

    Gevorgyan, Suren A.; Heckler, Ilona Maria; Bundgaard, Eva

    2017-01-01

    This review summarizes the recent progress in the stability and lifetime of organic photovoltaics (OPVs). In particular, recently proposed solutions to failure mechanisms in different layers of the device stack are discussed comprising both structural and chemical modifications. Upscaling...

  7. Light Emitting Diode (LED) circular traffic signal lifetime management system.

    Science.gov (United States)

    2011-02-01

    The objective of this research is to build lifetime curves for red, yellow, and green LED circular traffic signals through 20,000-hr. accelerated stress testing of samples operating under Louisianas environmental conditions.

  8. Practices of prolongation of the I and C equipment lifetime

    International Nuclear Information System (INIS)

    Samoylov, O.B.; Pronin, V.S.; Savelov, I.D.; Bogomazov, V.A.; Drumov, V.V.; Chudin, A.G.

    2000-01-01

    The lifetime of nuclear power plants (NPP) always exceeds the operational time of Instrumentation and Control (I and C) systems. Ageing of I and C equipment in NPPs have many aspects. Research of these aspects is being performed in OKB Mechanical Engineering. Under condition of fast development of I and C systems and applying more stringent safety requirements, modernization of the equipment irrespective of its operational condition is getting important. However, an equipment of I and C systems operated in Russia was designed and manufactured applying highest requirements for a reliability of their work during its whole operational time. Therefore, in many cases it is not necessary to replace them in spite of expiration of their specified lifetime. During operation this equipment is maintained in a proper operation condition by a special service procedures stipulated by its development. When the equipment lifetime approaches to its end, lifetime extension for the certain period should be considered. (author)

  9. Reliability-based assessment of polyethylene pipe creep lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Khelif, Rabia [LaMI-UBP and IFMA, Campus de Clermont-Fd, Les Cezeaux, BP 265, 63175 Aubiere Cedex (France); LR3MI, Departement de Genie Mecanique, Universite Badji Mokhtar, BP 12, Annaba 23000 (Algeria)], E-mail: rabia.khelif@ifma.fr; Chateauneuf, Alaa [LGC-University Blaise Pascal, Campus des Cezeaux, BP 206, 63174 Aubiere Cedex (France)], E-mail: alaa.chateauneuf@polytech.univ-bpclermont.fr; Chaoui, Kamel [LR3MI, Departement de Genie Mecanique, Universite Badji Mokhtar, BP 12, Annaba 23000 (Algeria)], E-mail: chaoui@univ-annaba.org

    2007-12-15

    Lifetime management of underground pipelines is mandatory for safe hydrocarbon transmission and distribution systems. The use of high-density polyethylene tubes subjected to internal pressure, external loading and environmental variations requires a reliability study in order to define the service limits and the optimal operating conditions. In service, the time-dependent phenomena, especially creep, take place during the pipe lifetime, leading to significant strength reduction. In this work, the reliability-based assessment of pipe lifetime models is carried out, in order to propose a probabilistic methodology for lifetime model selection and to determine the pipe safety levels as well as the most important parameters for pipeline reliability. This study is enhanced by parametric analysis on pipe configuration, gas pressure and operating temperature.

  10. Reliability-based assessment of polyethylene pipe creep lifetime

    International Nuclear Information System (INIS)

    Khelif, Rabia; Chateauneuf, Alaa; Chaoui, Kamel

    2007-01-01

    Lifetime management of underground pipelines is mandatory for safe hydrocarbon transmission and distribution systems. The use of high-density polyethylene tubes subjected to internal pressure, external loading and environmental variations requires a reliability study in order to define the service limits and the optimal operating conditions. In service, the time-dependent phenomena, especially creep, take place during the pipe lifetime, leading to significant strength reduction. In this work, the reliability-based assessment of pipe lifetime models is carried out, in order to propose a probabilistic methodology for lifetime model selection and to determine the pipe safety levels as well as the most important parameters for pipeline reliability. This study is enhanced by parametric analysis on pipe configuration, gas pressure and operating temperature

  11. Lifetime-Aware Cloud Data Centers: Models and Performance Evaluation

    Directory of Open Access Journals (Sweden)

    Luca Chiaraviglio

    2016-06-01

    Full Text Available We present a model to evaluate the server lifetime in cloud data centers (DCs. In particular, when the server power level is decreased, the failure rate tends to be reduced as a consequence of the limited number of components powered on. However, the variation between the different power states triggers a failure rate increase. We therefore consider these two effects in a server lifetime model, subject to an energy-aware management policy. We then evaluate our model in a realistic case study. Our results show that the impact on the server lifetime is far from negligible. As a consequence, we argue that a lifetime-aware approach should be pursued to decide how and when to apply a power state change to a server.

  12. Lifetime sedentary living accelerates some aspects of secondary aging

    DEFF Research Database (Denmark)

    Booth, Frank W; Laye, Matthew J; Roberts, Michael D

    2011-01-01

    Lifetime physical inactivity interacts with secondary aging (i.e., aging caused by diseases and environmental factors) in three patterns of response. First, lifetime physical inactivity confers no apparent effects on a given set of physiological functions. Second, lifetime physical inactivity...... accelerates secondary aging (e.g., speeding the reduction in bone mineral density, maximal oxygen consumption, and skeletal muscle strength and power), but does not alter the primary aging of these systems. Third, a lifetime of physical activity to the age of ∼60-70 yr old totally prevents decrements in some...... age-associated risk factors for major chronic diseases, such as endothelial dysfunction and insulin resistance. The present review provides ample and compelling evidence that physical inactivity has a large impact in shortening average life expectancy. In summary, physical inactivity plays a major...

  13. Measurement of the lifetime difference between Bs mass eigenstates

    International Nuclear Information System (INIS)

    Acosta, D.; The CDF Collaboration

    2005-01-01

    We present measurements of the lifetimes and polarization amplitudes for B s 0 → J/ψφ and B d 0 → J/ψ K* 0 decays. Lifetimes of the heavy (H) and light (L) mass eigenstates in the B s 0 system are separately measured for the first time by determining the relative contributions of amplitudes with definite CP as a function of the decay time

  14. Mean lifetime of the B$_{s}^{0}$ meson

    CERN Document Server

    Abreu, P; Adye, T; Agasi, E; Ajinenko, I; Aleksan, Roy; Alekseev, G D; Alemany, R; Allport, P P; Almehed, S; Amaldi, Ugo; Amato, S; Andreazza, A; Andrieux, M L; Antilogus, P; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barate, R; Barbi, M S; Barbiellini, Guido; Bardin, Dimitri Yuri; Baroncelli, A; Bärring, O; Barrio, J A; Bartl, Walter; Bates, M J; Battaglia, Marco; Baubillier, M; Baudot, J; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Benvenuti, Alberto C; Berggren, M; Bertrand, D; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bloch, D; Blume, M; Blyth, S; Bolognese, T; Bonesini, M; Bonivento, W; Booth, P S L; Borisov, G; Bosio, C; Bosworth, S; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozzo, M; Branchini, P; Brand, K D; Brenke, T; Brenner, R A; Bricman, C; Brillault, L; Brown, R C A; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschmann, P; Buys, A; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Cankocak, K; Cao, F; Carena, F; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerrito, L; Chabaud, V; Chapkin, M M; Charpentier, P; Chaussard, L; Chauveau, J; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Chudoba, J; Cindro, V; Collins, P; Contreras, J L; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; Dahl-Jensen, Erik; Dahm, J; D'Almagne, B; Dam, M; Damgaard, G; Dauncey, P D; Davenport, Martyn; Da Silva, W; Defoix, C; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; De Saint-Jean, C; Dijkstra, H; Di Ciaccio, Lucia; Djama, F; Dolbeau, J; Dönszelmann, M; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Elsing, M; Engel, J P; Ershaidat, N; Erzen, B; Espirito-Santo, M C; Falk, E; Fassouliotis, D; Feindt, Michael; Fenyuk, A; Ferrer, A; Filippas-Tassos, A; Firestone, A; Fischer, P A; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frenkiel, P; Fries, D E C; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gibbs, M; Gokieli, R; Golob, B; Gopal, Gian P; Gorn, L; Górski, M; Guz, Yu; Gracco, Valerio; Graziani, E; Grosdidier, G; Grzelak, K; Gumenyuk, S A; Gunnarsson, P; Günther, M; Guy, J; Hahn, F; Hahn, S; Hajduk, Z; Hallgren, A; Hamacher, K; Hao, W; Harris, F J; Hedberg, V; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Higón, E; Hilke, Hans Jürgen; Hill, T S; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Huet, K; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, Christian; Juillot, P; Kaiser, M; Kapusta, F; Karafasoulis, K; Karlsson, M; Karvelas, E; Katsanevas, S; Katsoufis, E C; Keränen, R; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klein, H; Klovning, A; Kluit, P M; Köne, B; Kokkinias, P; Koratzinos, M; Korcyl, K; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Kramer, P H; Krammer, Manfred; Kreuter, C; Kronkvist, I J; Krumshtein, Z; Krupinski, W; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Laktineh, I; Lamblot, S; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Lapin, V; Last, I; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leitner, R; Lemoigne, Y; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Liko, D; Lindner, R; Lipniacka, A; Lippi, I; Lörstad, B; Loken, J G; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Maehlum, G; Maio, A; Malychev, V; Mandl, F; Marco, J; Marco, R P; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Maron, T; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Masik, J; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; Medbo, J; Merk, M; Meroni, C; Meyer, S; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Morettini, P; Müller, H; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Niss, P; Nomerotski, A; Normand, Ainsley; Novák, M; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Ostankov, A P; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Pagès, P; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Passeri, A; Pegoraro, M; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Petrovykh, M; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Pindo, M; Plaszczynski, S; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Prest, M; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Ratoff, P N; Read, A L; Reale, M; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Renton, P B; Resvanis, L K; Richard, F; Richardson, J; Rídky, J; Rinaudo, G; Ripp, I; Romero, A; Roncagliolo, I; Ronchese, P; Roos, L; Rosenberg, E I; Rosso, E; Roudeau, Patrick; Rovelli, T; Rückstuhl, W; Ruhlmann-Kleider, V; Ruiz, A; Rybicki, K; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sánchez, J; Sannino, M; Schimmelpfennig, M; Schneider, H; Schwickerath, U; Schyns, M A E; Sciolla, G; Scuri, F; Seager, P; Sedykh, Yu; Segar, A M; Seitz, A; Sekulin, R L; Shellard, R C; Siccama, I; Siegrist, P; Simonetti, S; Simonetto, F; Sissakian, A N; Sitár, B; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stanescu, C; Stapnes, Steinar; Stavitski, I; Stichelbaut, F; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Tavernet, J P; Chikilev, O G; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Todorova, S; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tranströmer, G; Treille, D; Trischuk, W; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; Van der Velde, C; van Apeldoorn, G W; van Dam, P; Van Doninck, W K; Van Eldik, J; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Weierstall, M; Weilhammer, Peter; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J H; Wielers, M; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Woschnagg, K; Yip, K; Zach, F; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zito, M; Zontar, D; Zuberi, R; Zucchelli, G C; Zumerle, G

    1996-01-01

    This paper presents an update of the measurement of the mean lifetime of the B^0_s meson. Combining D_s - \\ell, D_s-h, \\phi - \\ell and inclusive D_s final states from the 3.2 million hadronic \\Zz decays collected by DELPHI between 1991 and 1994, the B^0_s mean lifetime was measured to be: \\tau(B^0_s) = 1.67 ~\\pm 0.14, M014AU

  15. Direct measurements of the lifetime of medium-heavy hypernuclei

    Science.gov (United States)

    Qiu, X.; Tang, L.; Chen, C.; Margaryan, A.; Wood, S. A.; Achenbach, P.; Ahmidouch, A.; Albayrak, I.; Androic, D.; Asaturyan, A.; Asaturyan, R.; Ates, O.; Badui, R.; Baturin, P.; Boeglin, W.; Bono, J.; Brash, E.; Carter, P.; Chen, X.; Chiba, A.; Christy, M. E.; Dalton, M. M.; Danagoulian, S.; De Leo, R.; Doi, D.; Elaasar, M.; Ent, R.; Fenker, H.; Fujii, Y.; Furic, M.; Gabrielyan, M.; Gan, L.; Garibaldi, F.; Gaskell, D.; Gasparian, A.; Gogami, T.; Hashimoto, O.; Horn, T.; Hu, B.; Hungerford, Ed V.; Jones, M.; Kanda, H.; Kaneta, M.; Kawama, D.; Khanal, H.; Kohl, M.; Liyanage, A.; Luo, W.; Maeda, K.; Markowitz, P.; Marikyan, G.; Maruta, T.; Matsumura, A.; Maxwell, V.; Mkrtchyan, A.; Mkrtchyan, H.; Nagao, S.; Nakamura, S. N.; Narayan, A.; Neville, C.; Niculescu, G.; Niculescu, M. I.; Nunez, A.; Nuruzzaman; Okayasu, Y.; Petkovic, T.; Pochodzalla, J.; Reinhold, J.; Rodriguez, V. M.; Samanta, C.; Sawatzky, B.; Seva, T.; Shichijo, A.; Tadevosyan, V.; Taniya, N.; Tsukada, K.; Veilleux, M.; Vulcan, W.; Wesselmann, F. R.; Yamamoto, T.; Ye, Z.; Yokota, K.; Yuan, L.; Zhamkochyan, S.; Zhu, L.; HKS (JLab E02-017) Collaboration

    2018-05-01

    The lifetime of a Λ particle embedded in a nucleus (hypernucleus) decreases from that of free Λ decay mainly due to the opening of the ΛN → NN weak decay channel. However, it is generally believed that the lifetime of a hypernucleus attains a constant value (saturation) for medium to heavy hypernuclear masses, yet this hypothesis has been difficult to verify. This paper presents a direct measurement of the lifetime of medium-heavy hypernuclei that were hyper-fragments produced by fission or break-up from heavy hypernuclei initially produced with a 2.34 GeV photon-beam incident on thin Fe, Cu, Ag, and Bi target foils. For each event, fragments were detected in coincident pairs by a low-pressure multi-wire proportional chamber system. The lifetime was extracted from decay time spectrum formed by the difference of the time zeros between the pairs. The measured lifetime from each target is actually a statistical average over a range of mass with mean about 1/2 of the target mass and appears to be a constant of about 200 ps. Although this result cannot exclude unexpected shorter or longer lifetimes for some specific hypernuclei or hypernuclear states, it shows that a systematic decrease in lifetime as hypernuclear mass increases is not a general feature for hypernuclei with mean mass up to A ≈ 130. On the other hand, the success of this experiment and its technique shows that the time delayed fissions observed and used by all the lifetime measurements done so far on heavy hypernuclei could likely have originated from hyper-fragments lighter than the assumed masses.

  16. Predictive Models of Li-ion Battery Lifetime

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Kandler; Wood, Eric; Santhanagopalan, Shriram; Kim, Gi-heon; Shi, Ying; Pesaran, Ahmad

    2015-06-15

    It remains an open question how best to predict real-world battery lifetime based on accelerated calendar and cycle aging data from the laboratory. Multiple degradation mechanisms due to (electro)chemical, thermal, and mechanical coupled phenomena influence Li-ion battery lifetime, each with different dependence on time, cycling and thermal environment. The standardization of life predictive models would benefit the industry by reducing test time and streamlining development of system controls.

  17. A precise measurement of the average b hadron lifetime

    CERN Document Server

    Buskulic, Damir; De Bonis, I; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Odier, P; Pietrzyk, B; Ariztizabal, F; Chmeissani, M; Crespo, J M; Efthymiopoulos, I; Fernández, E; Fernández-Bosman, M; Gaitan, V; Garrido, L; Martínez, M; Orteu, S; Pacheco, A; Padilla, C; Palla, Fabrizio; Pascual, A; Perlas, J A; Sánchez, F; Teubert, F; Colaleo, A; Creanza, D; De Palma, M; Farilla, A; Gelao, G; Girone, M; Iaselli, Giuseppe; Maggi, G; Maggi, M; Marinelli, N; Natali, S; Nuzzo, S; Ranieri, A; Raso, G; Romano, F; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Bonvicini, G; Cattaneo, M; Comas, P; Coyle, P; Drevermann, H; Engelhardt, A; Forty, Roger W; Frank, M; Hagelberg, R; Harvey, J; Jacobsen, R; Janot, P; Jost, B; Knobloch, J; Lehraus, Ivan; Markou, C; Martin, E B; Mato, P; Meinhard, H; Minten, Adolf G; Miquel, R; Oest, T; Palazzi, P; Pater, J R; Pusztaszeri, J F; Ranjard, F; Rensing, P E; Rolandi, Luigi; Schlatter, W D; Schmelling, M; Schneider, O; Tejessy, W; Tomalin, I R; Venturi, A; Wachsmuth, H W; Wiedenmann, W; Wildish, T; Witzeling, W; Wotschack, J; Ajaltouni, Ziad J; Bardadin-Otwinowska, Maria; Barrès, A; Boyer, C; Falvard, A; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rossignol, J M; Saadi, F; Fearnley, Tom; Hansen, J B; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Kyriakis, A; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Zachariadou, K; Blondel, A; Bonneaud, G R; Brient, J C; Bourdon, P; Passalacqua, L; Rougé, A; Rumpf, M; Tanaka, R; Valassi, Andrea; Verderi, M; Videau, H L; Candlin, D J; Parsons, M I; Focardi, E; Parrini, G; Corden, M; Delfino, M C; Georgiopoulos, C H; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Pepé-Altarelli, M; Dorris, S J; Halley, A W; ten Have, I; Knowles, I G; Lynch, J G; Morton, W T; O'Shea, V; Raine, C; Reeves, P; Scarr, J M; Smith, K; Smith, M G; Thompson, A S; Thomson, F; Thorn, S; Turnbull, R M; Becker, U; Braun, O; Geweniger, C; Graefe, G; Hanke, P; Hepp, V; Kluge, E E; Putzer, A; Rensch, B; Schmidt, M; Sommer, J; Stenzel, H; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Colling, D J; Dornan, Peter J; Konstantinidis, N P; Moneta, L; Moutoussi, A; Nash, J; San Martin, G; Sedgbeer, J K; Stacey, A M; Dissertori, G; Girtler, P; Kneringer, E; Kuhn, D; Rudolph, G; Bowdery, C K; Brodbeck, T J; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Sloan, Terence; Whelan, E P; Williams, M I; Galla, A; Greene, A M; Kleinknecht, K; Quast, G; Raab, J; Renk, B; Sander, H G; Wanke, R; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Bencheikh, A M; Benchouk, C; Bonissent, A; Bujosa, G; Calvet, D; Carr, J; Diaconu, C A; Etienne, F; Thulasidas, M; Nicod, D; Payre, P; Rousseau, D; Talby, M; Abt, I; Assmann, R W; Bauer, C; Blum, Walter; Brown, D; Dietl, H; Dydak, Friedrich; Ganis, G; Gotzhein, C; Jakobs, K; Kroha, H; Lütjens, G; Lutz, Gerhard; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Stierlin, U; Saint-Denis, R; Wolf, G; Alemany, R; Boucrot, J; Callot, O; Cordier, A; Courault, F; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacquet, M; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Musolino, G; Nikolic, I A; Park, H J; Park, I C; Schune, M H; Simion, S; Veillet, J J; Videau, I; Abbaneo, D; Azzurri, P; Bagliesi, G; Batignani, G; Bettarini, S; Bozzi, C; Calderini, G; Carpinelli, M; Ciocci, M A; Ciulli, V; Dell'Orso, R; Fantechi, R; Ferrante, I; Foà, L; Forti, F; Giassi, A; Giorgi, M A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Rizzo, G; Sanguinetti, G; Sciabà, A; Spagnolo, P; Steinberger, Jack; Tenchini, Roberto; Tonelli, G; Triggiani, G; Vannini, C; Verdini, P G; Walsh, J; Betteridge, A P; Blair, G A; Bryant, L M; Cerutti, F; Gao, Y; Green, M G; Johnson, D L; Medcalf, T; Mir, L M; Perrodo, P; Strong, J A; Bertin, V; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Edwards, M; Maley, P; Norton, P R; Thompson, J C; Bloch-Devaux, B; Colas, P; Duarte, H; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Marx, B; Pérez, P; Rander, J; Renardy, J F; Rosowsky, A; Roussarie, A; Schuller, J P; Schwindling, J; Si Mohand, D; Trabelsi, A; Vallage, B; Johnson, R P; Kim, H Y; Litke, A M; McNeil, M A; Taylor, G; Beddall, A; Booth, C N; Boswell, R; Cartwright, S L; Combley, F; Dawson, I; Köksal, A; Letho, M; Newton, W M; Rankin, C; Thompson, L F; Böhrer, A; Brandt, S; Cowan, G D; Feigl, E; Grupen, Claus; Lutters, G; Minguet-Rodríguez, J A; Rivera, F; Saraiva, P; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Ragusa, F; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Bellantoni, L; Elmer, P; Feng, P; Ferguson, D P S; Gao, Y S; González, S; Grahl, J; Harton, J L; Hayes, O J; Hu, H; McNamara, P A; Nachtman, J M; Orejudos, W; Pan, Y B; Saadi, Y; Schmitt, M; Scott, I J; Sharma, V; Turk, J; Walsh, A M; Wu Sau Lan; Wu, X; Yamartino, J M; Zheng, M; Zobernig, G

    1996-01-01

    An improved measurement of the average b hadron lifetime is performed using a sample of 1.5 million hadronic Z decays, collected during the 1991-1993 runs of ALEPH, with the silicon vertex detector fully operational. This uses the three-dimensional impact parameter distribution of lepton tracks coming from semileptonic b decays and yields an average b hadron lifetime of 1.533 \\pm 0.013 \\pm 0.022 ps.

  18. Habitable zone lifetimes of exoplanets around main sequence stars.

    Science.gov (United States)

    Rushby, Andrew J; Claire, Mark W; Osborn, Hugh; Watson, Andrew J

    2013-09-01

    The potential habitability of newly discovered exoplanets is initially assessed by determining whether their orbits fall within the circumstellar habitable zone of their star. However, the habitable zone (HZ) is not static in time or space, and its boundaries migrate outward at a rate proportional to the increase in luminosity of a star undergoing stellar evolution, possibly including or excluding planets over the course of the star's main sequence lifetime. We describe the time that a planet spends within the HZ as its "habitable zone lifetime." The HZ lifetime of a planet has strong astrobiological implications and is especially important when considering the evolution of complex life, which is likely to require a longer residence time within the HZ. Here, we present results from a simple model built to investigate the evolution of the "classic" HZ over time, while also providing estimates for the evolution of stellar luminosity over time in order to develop a "hybrid" HZ model. These models return estimates for the HZ lifetimes of Earth and 7 confirmed HZ exoplanets and 27 unconfirmed Kepler candidates. The HZ lifetime for Earth ranges between 6.29 and 7.79×10⁹ years (Gyr). The 7 exoplanets fall in a range between ∼1 and 54.72 Gyr, while the 27 Kepler candidate planets' HZ lifetimes range between 0.43 and 18.8 Gyr. Our results show that exoplanet HD 85512b is no longer within the HZ, assuming it has an Earth analog atmosphere. The HZ lifetime should be considered in future models of planetary habitability as setting an upper limit on the lifetime of any potential exoplanetary biosphere, and also for identifying planets of high astrobiological potential for continued observational or modeling campaigns.

  19. Fluorescence lifetime imaging of oxygen in dental biofilm

    Science.gov (United States)

    Gerritsen, Hans C.; de Grauw, Cees J.

    2000-12-01

    Dental biofilm consists of micro-colonies of bacteria embedded in a matrix of polysaccharides and salivary proteins. pH and oxygen concentration are of great importance in dental biofilm. Both can be measured using fluorescence techniques. The imaging of dental biofilm is complicated by the thickness of the biofilms that can be up to several hundred micrometers thick. Here, we employed a combination of two-photon excitation microscopy with fluorescence lifetime imaging to quantify the oxygen concentration in dental biofilm. Collisional quenching of fluorescent probes by molecular oxygen leads to a reduction of the fluorescence lifetime of the probe. We employed this mechanism to measure the oxygen concentration distribution in dental biofilm by means of fluorescence lifetime imaging. Here, TRIS Ruthenium chloride hydrate was used as an oxygen probe. A calibration procedure on buffers was use to measure the lifetime response of this Ruthenium probe. The results are in agreement with the Stern-Volmer equation. A linear relation was found between the ratio of the unquenched and the quenched lifetime and the oxygen concentration. The biofilm fluorescence lifetime imaging results show a strong oxygen gradient at the buffer - biofilm interface and the average oxygen concentration in the biofilm amounted to 50 μM.

  20. Multiphoton fluorescence lifetime imaging of chemotherapy distribution in solid tumors

    Science.gov (United States)

    Carlson, Marjorie; Watson, Adrienne L.; Anderson, Leah; Largaespada, David A.; Provenzano, Paolo P.

    2017-11-01

    Doxorubicin is a commonly used chemotherapeutic employed to treat multiple human cancers, including numerous sarcomas and carcinomas. Furthermore, doxorubicin possesses strong fluorescent properties that make it an ideal reagent for modeling drug delivery by examining its distribution in cells and tissues. However, while doxorubicin fluorescence and lifetime have been imaged in live tissue, its behavior in archival samples that frequently result from drug and treatment studies in human and animal patients, and murine models of human cancer, has to date been largely unexplored. Here, we demonstrate imaging of doxorubicin intensity and lifetimes in archival formalin-fixed paraffin-embedded sections from mouse models of human cancer with multiphoton excitation and multiphoton fluorescence lifetime imaging microscopy (FLIM). Multiphoton excitation imaging reveals robust doxorubicin emission in tissue sections and captures spatial heterogeneity in cells and tissues. However, quantifying the amount of doxorubicin signal in distinct cell compartments, particularly the nucleus, often remains challenging due to strong signals in multiple compartments. The addition of FLIM analysis to display the spatial distribution of excited state lifetimes clearly distinguishes between signals in distinct compartments such as the cell nuclei versus cytoplasm and allows for quantification of doxorubicin signal in each compartment. Furthermore, we observed a shift in lifetime values in the nuclei of transformed cells versus nontransformed cells, suggesting a possible diagnostic role for doxorubicin lifetime imaging to distinguish normal versus transformed cells. Thus, data here demonstrate that multiphoton FLIM is a highly sensitive platform for imaging doxorubicin distribution in normal and diseased archival tissues.

  1. Fluorescence lifetime evaluation of whole soils from the Amazon rainforest.

    Science.gov (United States)

    Nicolodelli, Gustavo; Tadini, Amanda Maria; Nogueira, Marcelo Saito; Pratavieira, Sebastião; Mounier, Stephane; Huaman, Jose Luis Clabel; Dos Santos, Cléber Hilário; Montes, Célia Regina; Milori, Débora Marcondes Bastos Pereira

    2017-08-20

    Time-resolved fluorescence spectroscopy (TRFS) is a new tool that can be used to investigate processes of interaction between metal ions and organic matter (OM) in soils, providing a specific analysis of the structure and dynamics of macromolecules. To the best of our knowledge, there are no studies in the literature reporting the use of this technique applied to whole/non-fractionated soil samples, making it a potential method for use in future studies. This work describes the use of TRFS to evaluate the fluorescence lifetimes of OM of whole soils from the Amazon region. Analysis was made of pellets of soils from an oxisol-spodosol system, collected in São Gabriel da Cachoeira (Amazonas, Brazil). The fluorescence lifetimes in the oxisol-spodosol system were attributed to two different fluorophores. One was related to complexation of an OM fraction with metals, resulting in a shorter fluorophore lifetime. A short fluorescence lifetime (2-12 ns) could be associated with simpler structures of the OM, while a long lifetime (19-66 ns) was associated with more complex OM structures. This new TRFS technique for analysis of the fluorescence lifetime in whole soil samples complies with the principles of green chemistry.

  2. Lifetime measurements in the picosecond range: Achievements and Perspectives

    International Nuclear Information System (INIS)

    Kruecken, Reiner

    1999-01-01

    This contribution will review the recoil distance method (RDM), its current range of applications as well as future perspectives for the measurement of lifetimes in the picosecond range of excited nuclear levels. Recent Doppler-shift lifetime experiments with large gamma-ray spectrometers have achieved a new level of precision and sensitivity, providing new insights into nuclear structure physics. High precision RDM measurements of near-yrast states in various mass regions have revealed dynamic shape effects beyond the framework of collective models and have also allowed to study the interaction between coexisting shapes. The measurement of lifetimes in superdeformed bands has shown that lifetimes can be measured for nuclear excitations, which are only populated with a few percent of the production cross-section of a nucleus. These experiments have also enabled us to study the mechanism of the decay-out of superdeformed bands. Another example for the need of precise lifetime measurements is the recent verifications of the concept of 'magnetic rotation' in nuclei by the experimental observation of the characteristic drop of B(M1) values as a function of angular momentum. These recent breakthroughs have also opened new perspectives for the use of the RDM technique for more exotic regions of nuclei and nuclear excitations. Here the measurement of lifetimes in neutron rich nuclei, which are not accessible with conventional nuclear reactions using stable beams and targets, is of special interest. Possible experimental approaches and simple estimates for the feasibility of such experiments will be presented. (author)

  3. Refractive index sensing using Fluorescence Lifetime Imaging (FLIM)

    International Nuclear Information System (INIS)

    Jones, Carolyn; Suhling, Klaus

    2006-01-01

    The fluorescence lifetime is a function of the refractive index of the fluorophore's environment, for example in the case of the biologically important green fluorescent protein (GFP). In order to address the question whether this effect can be exploited to image the local environment of specific proteins in cell biology, we need to determine the distance over which the fluorophore's lifetime is sensitive to the refractive index. To this end, we employ Fluorescence Lifetime Imaging (FLIM) of fluorescein in NaOH buffer at an interface. This approach allows us to map the fluorescence lifetime as a function of distance from a buffer/air and buffer/oil interface. Preliminary data show that the fluorescence lifetime of fluorescein increases near a buffer/air interface and decreases near a buffer/oil interface. The range over which this fluorescence lifetime change occurs is found to be of the order several μm which is consistent with a theoretical model based on the full width at half maximum of the emission spectrum proposed by Toptygin

  4. Genotypic-specific variance in Caenorhabditis elegans lifetime fecundity.

    Science.gov (United States)

    Diaz, S Anaid; Viney, Mark

    2014-06-01

    Organisms live in heterogeneous environments, so strategies that maximze fitness in such environments will evolve. Variation in traits is important because it is the raw material on which natural selection acts during evolution. Phenotypic variation is usually thought to be due to genetic variation and/or environmentally induced effects. Therefore, genetically identical individuals in a constant environment should have invariant traits. Clearly, genetically identical individuals do differ phenotypically, usually thought to be due to stochastic processes. It is now becoming clear, especially from studies of unicellular species, that phenotypic variance among genetically identical individuals in a constant environment can be genetically controlled and that therefore, in principle, this can be subject to selection. However, there has been little investigation of these phenomena in multicellular species. Here, we have studied the mean lifetime fecundity (thus a trait likely to be relevant to reproductive success), and variance in lifetime fecundity, in recently-wild isolates of the model nematode Caenorhabditis elegans. We found that these genotypes differed in their variance in lifetime fecundity: some had high variance in fecundity, others very low variance. We find that this variance in lifetime fecundity was negatively related to the mean lifetime fecundity of the lines, and that the variance of the lines was positively correlated between environments. We suggest that the variance in lifetime fecundity may be a bet-hedging strategy used by this species.

  5. Spontaneous body movements in spatial cognition

    Directory of Open Access Journals (Sweden)

    Sergiu eTcaci Popescu

    2012-05-01

    Full Text Available People often perform spontaneous body movements during spatial tasks such as giving complex directions or orienting themselves on maps. How are these spontaneous gestures related to spatial problem-solving? We measured spontaneous movements during a perspective-taking task inspired by map reading. Analyzing the motion data to isolate rotation and translation components of motion in specific geometric relation to the task, we found out that most participants executed spontaneous miniature rotations of the head that were significantly related to the main task parameter. These head rotations were as if participants were trying to align themselves with the orientation on the map either in the image plane or on the ground plane, but with tiny amplitudes, typically below 1% of the actual movements. Our results are consistent with a model of sensorimotor prediction driving spatial reasoning. The efference copy of planned movements triggers this prediction mechanism. The movements themselves may then be mostly inhibited; the small spontaneous gestures that we measure are the visible traces of these planned but inhibited actions.

  6. Bilateral spontaneous rupture of 'hale' kidneys

    International Nuclear Information System (INIS)

    Naumov, N.; Zozikov, B.; Otzetov, A.; Kamenova, M.; Martinova, F.; Kalyonski, R.

    2002-01-01

    A rare case of spontaneous bilateral rupture of the kidneys, occurring consecutively over a one-year period in a young male patient with 'hale' kidneys until then, is described. The patient's past history and thorough examination performed do not justify to assign the case under the heading of some of the etiological factors as the underlying cause of spontaneous kidney rupture. The literature survey on spontaneous bilateral non-tumor ruptures of kidneys shows that over a 20-year period, only 3 cases of bilateral spontaneous ruptures have been reported. It is pointed out that panarteritis nodosa followed by hemorrhagic fever with renal syndrome is the commonest underlying cause of such ruptures. Clinically spontaneous ruptures become manifest with emergency condition presenting severe renal colic, impaired to serious general condition, often with acute abdomen and hemodynamic breakdown, and no past history evidence of renal disease or injury. In the initial phase diagnosing is not always easy; it is usually made on the ground of physical examination and the full range of imaging studies used in urological practice and during operative treatment. Emphasis is laid on the fact that the imaging methods are not invariably sufficient to identify the exact etiological factor giving rise to such a severe condition, but nevertheless these methods have an essential practical bearing on diagnosing a rupture. (authors)

  7. Surgical management of spontaneous hypertensive brainstem hemorrhage

    Directory of Open Access Journals (Sweden)

    Bal Krishna Shrestha

    2015-09-01

    Full Text Available Spontaneous hypertensive brainstem hemorrhage is the spontaneous brainstem hemorrhage associated with long term hypertension but not having definite focal or objective lesion. It is a catastrophic event which has a poor prognosis and usually managed conservatively. It is not uncommon, especially in eastern Asian populations, accounting approximately for 10% of the intracerebral hemorrhage. Before the advent of computed tomography, the diagnosis of brainstem hemorrhage was usually based on the clinical picture or by autopsy and believed to be untreatable via surgery. The introduction of computed tomography permitted to categorize the subtypes of brainstem hemorrhage with more predicted outcome. Continuous ongoing developments in the stereotactic surgery and microsurgery have added more specific surgical management in these patients. However, whether to manage conservatively or promptly with surgical evacuation of hematoma is still a controversy. Studies have shown that an accurate prognostic assessment based on clinical and radiological features on admission is critical for establishing a reasonable therapeutic approach. Some authors have advocate conservative management, whereas others have suggested the efficacy of surgical treatment in brainstem hemorrhage. With the widening knowledge in microsurgical techniques as well as neuroimaging technology, there seems to have more optimistic hope of surgical management of spontaneous hypertensive brainstem hemorrhage for better prognosis. Here we present five cases of severe spontaneous hypertensive brainstem hemorrhage patients who had undergone surgery; and explore the possibilities of surgical management in patients with the spontaneous hypertensive brainstem hemorrhage.

  8. Cursed lamp: the problem of spontaneous abortion.

    Science.gov (United States)

    Simkulet, William

    2017-08-09

    Many people believe human fetuses have the same moral status as adult human persons, that it is wrong to allow harm to befall things with this moral status, and thus voluntary, induced abortion is seriously morally wrong. Recently, many prochoice theorists have argued that this antiabortion stance is inconsistent; approximately 60% of human fetuses die from spontaneous abortion, far more than die from induced abortion, so if antiabortion theorists really believe that human fetuses have significant moral status, they have strong moral obligations to oppose spontaneous abortion. Yet, few antiabortion theorists devote any effort to doing so. Many prochoice theorists argue that to resolve this inconsistency, antiabortion theorists should abandon their opposition to induced abortion. Here, I argue that those who do not abandon their opposition to induced abortion but continue to neglect spontaneous abortion act immorally. Aristotle argues that moral responsibility requires both control and awareness; I argue that once an antiabortion theorist becomes aware of the frequency of spontaneous abortion, they have a strong moral obligation to redirect their efforts towards combating spontaneous abortion; failure to do so is morally monstrous. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Spontaneous Regression of Lumbar Herniated Disc

    Directory of Open Access Journals (Sweden)

    Chun-Wei Chang

    2009-12-01

    Full Text Available Intervertebral disc herniation of the lumbar spine is a common disease presenting with low back pain and involving nerve root radiculopathy. Some neurological symptoms in the majority of patients frequently improve after a period of conservative treatment. This has been regarded as the result of a decrease of pressure exerted from the herniated disc on neighboring neurostructures and a gradual regression of inflammation. Recently, with advances in magnetic resonance imaging, many reports have demonstrated that the herniated disc has the potential for spontaneous regression. Regression coincided with the improvement of associated symptoms. However, the exact regression mechanism remains unclear. Here, we present 2 cases of lumbar intervertebral disc herniation with spontaneous regression. We review the literature and discuss the possible mechanisms, the precipitating factors of spontaneous disc regression and the proper timing of surgical intervention.

  10. Spontaneous hemothorax: primary pleural epithelioid angiosarcoma

    Directory of Open Access Journals (Sweden)

    Amit Panjwani

    2016-01-01

    Full Text Available Spontaneous hemothorax is a rare condition seen in coagulation and vascular disorders. Uncommonly, malignant neoplasms may cause spontaneous hemothorax. Primary pleural epithelioid angiosarcomas (excluding the cases with pleuropulmonary or chest wall involvement are extremely rare pleural tumors, which may be mistaken for mesothelioma or adenocarcinoma, and only 19 cases (one of them from India have been reported in the English literature, to date. It commonly occurs in older men, has a nonspecific clinicoradiological presentation, and carries a poor prognosis with no survivors beyond a year of establishing the diagnosis. We report a case of primary pleural epithelioid angiosarcoma presenting as a life-threatening spontaneous hemothorax. We also present a brief literature review on pleural angiosarcoma.

  11. Computed tomographic findings of spontaneous intracranial hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Seung Sook; Kim, Young Sook; Kim, Young Chul [College of Medicine, Chosun University, Kwangju (Korea, Republic of)

    1987-10-15

    Computed tomography (CT) was a reliable technique to evaluate the exact size and location of spontaneous intracranial hemorrhage and to predict it's prognosis. Fifty-nine cases of spontaneous intracranial hemorrhage were evaluated and reviewed by CT scan. The following results were obtained. 1. The sex ratio of male to female was 1 to 1.4, The highest incidence was in 6th and 7th decades. 2. The most common cause of spontaneous intracranial hemorrhage was hypertension (74.6%), followed by the aneurysm (13.5%), arteriovenous malformation (5.1%), occlusive vascular disease (3.4%), and blood dyscrasia (3.4%). 3. The most common location was basal ganglia and thalamic hemorrhage (37.3%), followed by lobar hemorrhage (27.1%), cerebellar hemorrhage (13.5%), and subarachnoid hemorrhage (11.9%). 4. Primary intraventricular hemorrhage carried the highest mortality. 5. The larger volume of hematoma, the higher the mortality rate.

  12. Spontaneous Perforation of Pyometra: A Case Report

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available Pyometra is the accumulation of purulent material in the uterine cavity. Its reported incidence is 0.01–0.5% in gynecologic patients; however, as far as elderly patients are concerned, its incidence is 13.6% [3]. The most common cause of pyometra is malignant diseases of genital tract and the consequences of their treatment (radiotherapy. Other causes are benign tumors like leiomyoma, endometrial polyps, senile cervicitis, cervical occlusion after surgery, puerperal infections, and congenital cervical anomalies. Spontaneous rupture of the uterus is an extremely rare complication of pyometra. To our knowledge, only 21 cases of spontaneous perforation of pyometra have been reported in English literature since 1980. This paper reports an additional case of spontaneous uterine rupture.

  13. Lifetime physical activity and female stress urinary incontinence.

    Science.gov (United States)

    Nygaard, Ingrid E; Shaw, Janet M; Bardsley, Tyler; Egger, Marlene J

    2015-07-01

    We sought to estimate whether moderate/severe stress urinary incontinence (SUI) in middle-aged women is associated with overall lifetime physical activity (including leisure, household, outdoor, and occupational), as well as lifetime leisure (recreational), lifetime strenuous, and strenuous activity during the teen years. Recruitment for this case-control study was conducted in primary-care-level family medicine and gynecology clinics. A total of 1538 enrolled women ages 39-65 years underwent a Pelvic Organ Prolapse Quantification examination to assess vaginal support. Based on Incontinence Severity Index scores, cases had moderate/severe and controls had no/mild SUI. We excluded 349 with vaginal descent at/below the hymen (pelvic organ prolapse), 194 who did not return questionnaires, and 110 with insufficient activity data for analysis. In all, 213 cases were frequency matched 1:1 by age group to controls. Physical activity was measured using the Lifetime Physical Activity Questionnaire, in which women recall activity from menarche to present. We created separate multivariable logistic regression models for activity measures. SUI odds increased slightly with overall lifetime activity (odds ratio [OR], 1.20 per 70 additional metabolic equivalent of task-h/wk; 95% confidence interval [CI], 1.02-1.41), and were not associated with lifetime strenuous activity (OR, 1.11; 95% CI, 0.99-1.25). In quintile analysis of lifetime leisure activity, which demonstrated a nonlinear pattern, all quintiles incurred about half the odds of SUI compared to reference (second quintile; P = .009). Greater strenuous activity in teen years modestly increased SUI odds (OR, 1.37 per 7 additional h/wk; 95% CI, 1.09-1.71); OR, 1.75; 95% CI, 1.15-2.66 in sensitivity analysis adjusting for measurement error. The predicted probability of SUI rose linearly in women exceeding 7.5 hours of strenuous activity/wk during teen years. Teen strenuous activity had a similar effect on SUI odds when

  14. On spontaneous breakdown in Σ-models

    International Nuclear Information System (INIS)

    Ivanov, E.A.

    1975-01-01

    The group theory aspects of spontaneous breakdown in linear Σ-models are discussed. General conditions are formulated under which multiplet of group G (compact or noncompact) is suitable for constructing the Σ-model with a given subgroup of stability of vacuum. It is shown that the Σ-models of spontaneously broken space-time symmetries can be constructed in general only if some extra coordinates are introduced in addition to an ordinary 4-coordinate xsub(μ). The connection between Σ-models of internal symmetries and appropriate nonlinear realizations has also been investigated

  15. Two cases of spontaneous temporal encephalocele.

    Science.gov (United States)

    Kamiya, Kouhei; Mori, Harushi; Kunimatsu, Akira; Kawai, Kensuke; Usami, Kenichi; Ohtomo, Kuni

    2012-12-01

    This is a report of two cases of spontaneous temporal encephalocele: one was anteroinferior and presented with epilepsy; the other was posteroinferior and presented with facial neuritis and labyrinthitis. Spontaneous temporal encephalocele is relatively rare and apparently not familiar to a majority of primary physicians. It may present with a variety of symptoms according to its anatomical location, including cerebrospinal fluid fistulas, recurrent meningitis, chronic otitis media, hearing loss, facial nerve palsy and medically intractable epilepsy. Attention should be paid to this disease entity, as it is easily overlooked in imaging studies and can leave serious neurological deficits. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  16. Spontaneous abortion and physical strain around implantation

    DEFF Research Database (Denmark)

    Hjollund, N H; Jensen, Tina Kold; Bonde, Jens Peter

    2000-01-01

    Existing studies of physical strain and spontaneous abortion are mainly retrospective or based only on pregnancies that have survived the first trimester. Furthermore, almost all studies have relied on averaged measures of physical strain, which tend to blur an effect if peak values during short...... pregnancy the women recorded physical strain prospectively in a structured diary. Physical strain around the time of implantation was associated with later spontaneous abortion. The adjusted risk ratio for women who reported physical strain higher than average at day 6 to 9 after the estimated date...

  17. Need for spontaneous breakdown of chiral symmetry

    International Nuclear Information System (INIS)

    Salomone, A.; Schechter, J.; Tudron, T.

    1981-01-01

    The question of whether the chiral symmetry of the theory of strong interactions (with massless quarks) is required to be spontaneously broken is examined in the framework of a previously discussed effective Lagrangian for quantum chromodynamics. The assumption that physical masses of the theory be finite leads in a very direct way to the necessity of spontaneous breakdown. This result holds for all N/sub F/> or =2, where N/sub F/ is the number of different flavors of light quarks. The atypical cases N/sub F/ = 1,2 are discussed separately

  18. Spontaneous subdural hematoma associated to Duret hemorrhage

    Directory of Open Access Journals (Sweden)

    William Alves Martins, MD

    2015-03-01

    Full Text Available Subdural hematoma (SH is a neurosurgical emergency, usually caused by head trauma. Non-traumatic causes include aneurysm or arterial–venous malformation rupture, coagulopathy and others. We report the case of a 66 year-old man who developed apparently unprovoked signs of increased intracranial pressure. Brain computed tomography scan showed an acute spontaneous SH, surgically treated. Throughout surgery, a ruptured cortical artery with intensive bleeding appeared and was cauterized. After surgery, patient remained comatose and a new CT demonstrated Duret hemorrhage at the brainstem. Acute spontaneous SH of arterial origin is rare and highly lethal, in which a good prognosis relies on early diagnosis and treatment.

  19. Primer on spontaneous heating and pyrophoricity

    Energy Technology Data Exchange (ETDEWEB)

    1994-12-01

    This primer was prepared as an information resource for personnel responsible for operation of DOE nuclear facilities. It has sections on combustion principles, spontaneous heating/ignition of hydrocarbons and organics, pyrophoric gases and liquids, pyrophoric nonmetallic solids, pyrophoric metals (including Pu and U), and accident case studies. Although the information in this primer is not all-encompassing, it should provide the reader with a fundamental knowledge level sufficient to recognize most spontaneous combustion hazards and how to prevent ignition and widespread fires. This primer is provided as an information resource only, and is not intended to replace any fire protection or hazardous material training.

  20. Cavity enhanced rephased amplified spontaneous emission

    International Nuclear Information System (INIS)

    A Williamson, Lewis; J Longdell, Jevon

    2014-01-01

    Amplified spontaneous emission is usually treated as an incoherent noise process. Recent theoretical and experimental work using rephasing optical pulses has shown that rephased amplified spontaneous emission (RASE) is a potential source of wide bandwidth time-delayed entanglement. Due to poor echo efficiency the plain RASE protocol does not in theory achieve perfect entanglement. Experiments done to date show a very small amount of entanglement at best. Here we show that RASE can, in principle, produce perfect multimode time-delayed two mode squeezing when the active medium is placed inside a Q-switched cavity. (paper)

  1. Spontaneous supersymmetry breaking on the lattice

    Energy Technology Data Exchange (ETDEWEB)

    Wenger, Urs [Albert Einstein Center for Fundamental Physics, Institute for Theoretical Physics, University of Bern, Sidlerstrasse 5, CH-3012 Bern (Switzerland)

    2013-07-01

    We discuss various strategies for regularising supersymmetric quantum field theories on a space-time lattice. In general, simulations of lattice models with spontaneously broken supersymmetry suffer from a fermion sign problem related to the vanishing of the Witten index. We discuss a novel approach which evades this problem in low dimensions by formulating the path integral on the lattice in terms of fermion loops. Then we present exact results on the spectrum and the Witten index for N=2 supersymmetric quantum mechanics and results from simulations of the spontaneously broken N=1 Wess-Zumino model.

  2. Spontaneous extrusion of ventriculoperitoneal catheter through ...

    African Journals Online (AJOL)

    Ventriculo-peritoneal shunting is the commonest surgery for management of hydrocephalus. However, about 80% develop complications in their lifetime. These include common ones like shunt blockage and infection, to rare ones like shunt migration, extrusion and perforation of viscus. The authors present a rare case of ...

  3. Maximizing Lifetime of Wireless Sensor Networks with Mobile Sink Nodes

    Directory of Open Access Journals (Sweden)

    Yourong Chen

    2014-01-01

    Full Text Available In order to maximize network lifetime and balance energy consumption when sink nodes can move, maximizing lifetime of wireless sensor networks with mobile sink nodes (MLMS is researched. The movement path selection method of sink nodes is proposed. Modified subtractive clustering method, k-means method, and nearest neighbor interpolation method are used to obtain the movement paths. The lifetime optimization model is established under flow constraint, energy consumption constraint, link transmission constraint, and other constraints. The model is solved from the perspective of static and mobile data gathering of sink nodes. Subgradient method is used to solve the lifetime optimization model when one sink node stays at one anchor location. Geometric method is used to evaluate the amount of gathering data when sink nodes are moving. Finally, all sensor nodes transmit data according to the optimal data transmission scheme. Sink nodes gather the data along the shortest movement paths. Simulation results show that MLMS can prolong network lifetime, balance node energy consumption, and reduce data gathering latency under appropriate parameters. Under certain conditions, it outperforms Ratio_w, TPGF, RCC, and GRND.

  4. Lifetime prevalence of trauma among homeless people in Sydney.

    Science.gov (United States)

    Buhrich, N; Hodder, T; Teesson, M

    2000-12-01

    The experience of lifetime trauma among homeless women in the USA is well documented. Less information is available concerning homeless men. There are no prevalence studies concerning lifetime trauma among homeless people in Australia. Our aim was to assess the lifetime prevalence of trauma as reported by homeless men and women in Sydney. We interviewed 119 men and 38 women who were visiting or residing at the seven largest refuges for homeless people in inner Sydney, using the lifetime trauma section of the Composite International Diagnostic Interview. All women and over 90% of men reported at least one event of trauma in their life. Fifty-eight per cent suffered serious physical assault and 55% witnessed someone being badly injured or killed. Half the women and 10% of men reported that they had been raped. The experience of at least one lifetime event of trauma is almost universal among homeless people in Sydney and is considerably higher than for the USA general population. Reasons for such high prevalence rates are discussed. Depression and posttraumatic stress disorder are associated with a history of trauma. Health professionals need to be aware of past events of trauma among individuals who are homeless.

  5. Optimized inspection techniques and structural analysis in lifetime management

    International Nuclear Information System (INIS)

    Aguado, M.T.; Marcelles, I.

    1993-01-01

    Preservation of the option of extending the service lifetime of a nuclear power plant beyond its normal design lifetime requires correct remaining lifetime management from the very beginning of plant operation. The methodology used in plant remaining lifetime management is essentially based on the use of standard inspections, surveillance and monitoring programs and calculations, such as thermal-stress and fracture mechanics analysis. The inspection techniques should be continuously optimized, in order to be able to detect and dimension existing defects with the highest possible degree of accuracy. The information obtained during the inspection is combined with the historical data of the components: design, quality, operation, maintenance, and transients, and with the results of destructive testing, fracture mechanics and thermal fatigue analysis. These data are used to estimate the remaining lifetime of nuclear power plant components, systems and structures with the highest degree possible of accuracy. The use of this methodology allows component repairs and replacements to be reduced or avoided and increases the safety levels and availability of the nuclear power plant. Use of this strategy avoids the need for heavy investments at the end of the licensing period

  6. Wheaten ferments spontaneous fermantation in biotechnological methods

    OpenAIRE

    KAKHRAMON SANOQULOVICH RAKHMONOV; ISABAEV ISMAIL BABADJANOVICH

    2016-01-01

    In article are shown results of research of biotechnological properties of wheaten leavens of spontaneous fermentation (in the example of pea-anisetree leaven) and their analysis. Also is established influence of the given type of leavens on the basic biopolymers of the flour, on the property of the pastry and quality of bread from wheaten flour.

  7. Original article Spontaneous Pregnancy Outcome after Surgical ...

    African Journals Online (AJOL)

    2011-09-28

    Sep 28, 2011 ... Table 2: Spontaneous pregnancy in relation to postoperative semen parameters. (no statistically significant difference), comparable to the mean ages of 22, 28.4 and. 34.9 years, respectively, reported by Bach et al9, Abdel- Meguid et al10 and Baazeem et al11. The mean age of the wives who did or did.

  8. Spontaneous symmetry breakdown in gauge theories

    International Nuclear Information System (INIS)

    Scadron, M.D.

    1982-01-01

    The dynamical theory of spontaneous breakdown correctly predicts the bound states and relates the order parameters of electron-photon superconductivity and quark-gluon chiral symmetry. A similar statement cannot be made for the standard electro-weak gauge symmetry. (author)

  9. Identical Twin Primigravid Sisters -Spontaneous Labour and ...

    African Journals Online (AJOL)

    We report 2 cases of identical twin sisters, the older sibling getting married 14 months earlier but both got pregnant for their first child at about the same time and were managed by the same Obstetrician and fell into spontaneous labour within a few hours of each other. Both were delivered by emergency caesarean section ...

  10. SPONTANEOUS CP VIOLATION AND QUARK MASS AMBIGUITIES.

    Energy Technology Data Exchange (ETDEWEB)

    CREUTZ,M.

    2004-09-21

    I explore the regions of quark masses where CP will be spontaneously broken in the strong interactions. The boundaries of these regions are controlled by the chiral anomaly, which manifests itself in ambiguities in the definition of non-degenerate quark masses. In particular, the concept of a single massless quark is ill defined.

  11. 1 INFLUENCE OF SPONTANEOUS FERMENTATION ON SOME ...

    African Journals Online (AJOL)

    RopSvr

    Spontaneous fermentation has been identified to improve the quality characteristics of foods derived from them. When combined with cowpea fortification and nixtamalization, it is expected to improve the nutritional, functional, physico-chemical and sensory qualities of maize based foods thereby improving the qualities as ...

  12. Association between Nutritional Status with Spontaneous Abortion

    Directory of Open Access Journals (Sweden)

    Rahimeh Ahmadi

    2016-11-01

    Full Text Available Background: Spontaneous abortion is the most common adverse pregnancy outcome. We aimed to investigate a possible link between nutrient deficiencies and the risk of spontaneous abortion. Materials and Methods: This case-control study included the case group (n=331 experiencing a spontaneous abortion before 14 weeks of pregnancy and the control group (n=331 who were healthy pregnant women over 14 weeks of pregnancy. The participants filled out Food Frequency Questionnaire (FFQ, in which they reported their frequency of consumption for a given serving of each food item during the past three months, on a daily, weekly or monthly basis. The reported frequency for each food item was converted to a daily intake. Then, consumption of nutrients was compared between the two groups. Results: There are significant differences between the two groups regarding consumed servings/day of vegetables, bread and cereal, meat, poultry, fish, eggs, beans, fats, oils and dairy products (P=0.012, P<0.001, P=0.004, P<0.001, P=0.019, respectively. There are significant differences between the two groups in all micronutrient including folic acid, iron, vitamin C, vitamin B6, vitamin B12 and zinc (P<0.001. Conclusion: Poor nutrientions may be correlated with increased risk of spontaneous abortion

  13. Spontaneous regression of an intraspinal disc cyst

    Energy Technology Data Exchange (ETDEWEB)

    Demaerel, P.; Eerens, I.; Wilms, G. [University Hospital, Leuven (Belgium). Dept. of Radiology; Goffin, J. [Dept. of Neurosurgery, University Hospitals, Leuven (Belgium)

    2001-11-01

    We present a patient with a so-called disc cyst. Its location in the ventrolateral epidural space and its communication with the herniated disc are clearly shown. The disc cyst developed rapidly and regressed spontaneously. This observation, which has not been reported until now, appears to support focal degeneration with cyst formation as the pathogenesis. (orig.)

  14. Spontaneous rupture of an infected renal cyst

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, W.; Toelly, E.; Ebner, F.; Kullnig, P.

    1986-07-01

    Spontaneous or traumatic rupture of renal cysts is a rare occurrence. The contents of the cyst can perforate into the renal calyx system or into the perirenal space. Perforation into the peritoneal cavity has also been described (1, 2, 4, 5).

  15. Proteomic Biomarkers for Spontaneous Preterm Birth

    DEFF Research Database (Denmark)

    Kacerovsky, Marian; Lenco, Juraj; Musilova, Ivana

    2014-01-01

    This review aimed to identify, synthesize, and analyze the findings of studies on proteomic biomarkers for spontaneous preterm birth (PTB). Three electronic databases (Medline, Embase, and Scopus) were searched for studies in any language reporting the use of proteomic biomarkers for PTB published...

  16. Spontaneous emission from saturated parametric amplifiers

    DEFF Research Database (Denmark)

    Rottwitt, Karsten; Ott, Johan Raunkjær; Steffensen, Henrik

    2009-01-01

    Noise performance of parametric amplifiers is typically calculated assuming un-depleted operation. However, in many applications especially when applied as regenerative amplifiers in systems based on phase shift keyed modulation schemes, this assumption is not valid. Here we show the impact...... on accumulated spontaneous emission for a parametric amplifier operated in saturation....

  17. Spontaneous Non-verbal Counting in Toddlers

    Science.gov (United States)

    Sella, Francesco; Berteletti, Ilaria; Lucangeli, Daniela; Zorzi, Marco

    2016-01-01

    A wealth of studies have investigated numerical abilities in infants and in children aged 3 or above, but research on pre-counting toddlers is sparse. Here we devised a novel version of an imitation task that was previously used to assess spontaneous focusing on numerosity (i.e. the predisposition to grasp numerical properties of the environment)…

  18. Editorial: Spontaneous bacterial peritonitis | Lule | East African ...

    African Journals Online (AJOL)

    Journal Home > Vol 81, No 3 (2004) >. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register. Editorial: Spontaneous bacterial peritonitis. GN Lule. Abstract. No Abstract Available. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT ...

  19. Spontaneous conversion of first onset atrial fibrillation

    DEFF Research Database (Denmark)

    Lindberg, Søren Østergaard; Hansen, Sidsel; Nielsen, Tonny

    2011-01-01

    Background  We studied all patients admitted to hospital with first onset atrial fibrillation (AF) to determine the probability of spontaneous conversion to sinus rhythm and to identify factors predictive of such a conversion. Methods and Results  We retrospectively reviewed charts of 438...

  20. Spontaneous dimensional reduction in quantum gravity

    Science.gov (United States)

    Carlip, S.

    2016-07-01

    Hints from a number of different approaches to quantum gravity point to a phenomenon of “spontaneous dimensional reduction” to two spacetime dimensions near the Planck scale. I examine the physical meaning of the term “dimension” in this context, summarize the evidence for dimensional reduction, and discuss possible physical explanations.

  1. Surgical management of spontaneous ruptured hepatocellular adenoma

    Directory of Open Access Journals (Sweden)

    Marcelo Augusto Fontenelle Ribeiro Junior

    2009-01-01

    Full Text Available AIMS: Spontaneous ruptured hepatocellular adenoma (SRHA is a rare life-threatening condition that may require surgical treatment to control hemorrhaging and also stabilize the patient. We report a series of emergency surgeries performed at our institution for this condition. METHODS: We reviewed medical records and radiology files of 28 patients (from 1989 to 2006 with a proven diagnosis of hepatocellular adenoma (HA. Three (10.7% of 28 patients had spontaneous ruptured hepatocellular adenoma, two of which were associated with intrahepatic hemorrhage while one had intraperitoneal bleeding. Two patients were female and one was male. Both female patients had a background history of oral contraceptive use. Sudden abdominal pain associated with hemodynamic instability occurred in all patients who suffered from spontaneous ruptured hepatocellular adenoma. The mean age was 41.6 years old. The preoperative assessment included liver function tests, ultrasonography and computed tomography. RESULTS: The surgical approaches were as follows: right hemihepatectomy for controlling intraperitoneal bleeding, and right extended hepatectomy and non-anatomic resection of the liver for intrahepatic hemorrhage. There were no deaths, and the postoperative complications were bile leakage and wound infection (re-operation, as well as intraperitoneal abscess (re-operation and pleural effusion. CONCLUSION: Spontaneous ruptured hepatocellular adenoma may be treated by surgery for controlling hemorrhages and stabilizing the patient, and the decision to operate depends upon both the patient's condition and the expertise of the surgical team.

  2. Chronic Allium sativum administration alters spontaneous ...

    African Journals Online (AJOL)

    This study was conducted to investigate the effects of Allium sativum extract on the medial prefrontal cortex and neurobehaviour of adult Wistar rats. ... altered spontaneous alternation, while cellular pathologic changes were observed in the medial prefrontal cortex of these test groups in a dose dependent sequence.

  3. Spontaneous hedonic reactions to social media cues

    NARCIS (Netherlands)

    Koningsbruggen, G.M. van; Hartmann, T.; Eden, A.; Veling, H.P.

    2017-01-01

    Why is it so difficult to resist the desire to use social media? One possibility is that frequent social media users possess strong and spontaneous hedonic reactions to social media cues, which, in turn, makes it difficult to resist social media temptations. In two studies (total N = 200), we

  4. Recurrent spontaneous intracerebral hemorrhage associated with ...

    African Journals Online (AJOL)

    Spontaneous intracerebral hemorrhage (ICH) accounts for 15% of stroke cases in the US and Europe and up to 30% in Asian populations. Intracerebral hemorrhage is a relatively uncommon form of stroke-it causes only 10 to 15 percent of all strokes. It is more disabling and has a higher mortality rate than ischemic stroke, ...

  5. Ovarian hyperstimulation syndrome in a spontaneous pregnancy ...

    African Journals Online (AJOL)

    It is known that most cases of Ovarian Hyperstimulation Syndrome (OHSS) are associated with the therapies for ovulation induction. However, OHSS may rarely be associated with a spontaneous ovulatory cycle, usually in the case of multiple gestations, hypothyroidism or polycystic ovary syndrome. We report a case of ...

  6. Spontaneous left main coronary artery dissection

    Directory of Open Access Journals (Sweden)

    Alptug Tokatli

    2016-03-01

    Full Text Available Spontaneous coronary artery dissection (SCAD is a very rare clinical condition. Physiopathology of SCAD is still mostly unclear. Clinical presentation of SCAD ranges from atypical symptoms to sudden cardiac death. The diagnosis of dissection is generally made by using conventional coronary angiography. Invasive or conservative treatment is reasonable.

  7. Spontaneous extracranial decompression of epidural hematoma

    International Nuclear Information System (INIS)

    Neely, John C.; Jones, Blaise V.; Crone, Kerry R.

    2008-01-01

    Epidural hematoma (EDH) is a common sequela of head trauma in children. An increasing number are managed nonsurgically, with close clinical and imaging observation. We report the case of a traumatic EDH that spontaneously decompressed into the subgaleal space, demonstrated on serial CT scans that showed resolution of the EDH and concurrent enlargement of the subgaleal hematoma. (orig.)

  8. Spontaneous extracranial decompression of epidural hematoma

    Energy Technology Data Exchange (ETDEWEB)

    Neely, John C. [Marshall University School of Medicine, Huntington, WV (United States); Jones, Blaise V. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Crone, Kerry R. [Cincinnati Children' s Hospital Medical Center, Division of Neurosurgery, Cincinnati, OH (United States)

    2008-03-15

    Epidural hematoma (EDH) is a common sequela of head trauma in children. An increasing number are managed nonsurgically, with close clinical and imaging observation. We report the case of a traumatic EDH that spontaneously decompressed into the subgaleal space, demonstrated on serial CT scans that showed resolution of the EDH and concurrent enlargement of the subgaleal hematoma. (orig.)

  9. Spontaneous Sourcing among Students Reading Multiple Documents

    Science.gov (United States)

    Stromso, Helge I.; Braten, Ivar; Britt, M. Anne; Ferguson, Leila E.

    2013-01-01

    This study used think-aloud methodology to explore undergraduates' spontaneous attention to and use of source information while reading six documents that presented conflicting views on a controversial social scientific issue in a Google-like environment. Results showed that students explicitly and implicitly paid attention to sources of documents…

  10. Massive Spontaneous Hemothorax, Giant Intrathoracic Meningocele ...

    African Journals Online (AJOL)

    haemothorax associated with von Recklinghausen's disease: Review of occurrence in Japan. Thorax 1997;52:575‑8. 3. Fedoruk LM, English J, Fradet GJ. Spontaneous hemothorax and neurofibromatosis: A review of a lethal combination. Asian Cardiovasc. Thorac Ann 2007;15:342‑4. 4. Conlon NP, Redmond KC, Celi LA.

  11. A Fatal Complication of Dermatomyositis: Spontaneous Pneumomediastinum

    Directory of Open Access Journals (Sweden)

    Ezgi Demirdöğen Çetinoğlu

    2016-04-01

    Full Text Available Interstitial lung disease (ILD is a negative prognostic factor associated with increased morbidity and mortality in patients with dermatomyositis (DM. Spontaneous pneumomediastinum is a rare complication of DM and it can be fatal. We present a 48-year-old woman with DM and ILD complicated by pneumomediastinum without pneumothorax and subcutaneous emphysema.

  12. Grooming behavior of spontaneously hypertensive rats

    NARCIS (Netherlands)

    Buuse, M. van den; Jong, Wybren de

    1987-01-01

    In an open field spontaneously hypertensive rats (SHR) exhibited lower scores for grooming when compared to their normotensive controls, the Wistar Kyoto rats (WKY). After i.c.v. injection of 1 μg ACTH1–24 cumulative 50-min grooming scores were lower in SHR. Analysis of subscores indicated that the

  13. Spontaneous abortion and physical strain around implantation

    DEFF Research Database (Denmark)

    Hjollund, N H; Jensen, Tina Kold; Bonde, Jens Peter

    2000-01-01

    Existing studies of physical strain and spontaneous abortion are mainly retrospective or based only on pregnancies that have survived the first trimester. Furthermore, almost all studies have relied on averaged measures of physical strain, which tend to blur an effect if peak values during short ...

  14. Spontaneous Hedonic Reactions to Social Media Cues.

    Science.gov (United States)

    van Koningsbruggen, Guido M; Hartmann, Tilo; Eden, Allison; Veling, Harm

    2017-05-01

    Why is it so difficult to resist the desire to use social media? One possibility is that frequent social media users possess strong and spontaneous hedonic reactions to social media cues, which, in turn, makes it difficult to resist social media temptations. In two studies (total N = 200), we investigated less-frequent and frequent social media users' spontaneous hedonic reactions to social media cues using the Affect Misattribution Procedure-an implicit measure of affective reactions. Results demonstrated that frequent social media users showed more favorable affective reactions in response to social media (vs. control) cues, whereas less-frequent social media users' affective reactions did not differ between social media and control cues (Studies 1 and 2). Moreover, the spontaneous hedonic reactions to social media (vs. control) cues were related to self-reported cravings to use social media and partially accounted for the link between social media use and social media cravings (Study 2). These findings suggest that frequent social media users' spontaneous hedonic reactions in response to social media cues might contribute to their difficulties in resisting desires to use social media.

  15. Spontaneous electric fields in solid films: spontelectrics

    DEFF Research Database (Denmark)

    Field, David; Plekan, Oksana; Cassidy, Andrew

    2013-01-01

    When dipolar gases are condensed at sufficiently low temperature onto a solid surface, they form films that may spontaneously exhibit electric fields in excess of 108V/m. This effect, called the ‘spontelectric effect’, was recently revealed using an instrument designed to measure scattering...

  16. Spontaneous Retroperitoneal Hemorrhage from Adrenal Artery Aneurysm

    International Nuclear Information System (INIS)

    Gonzalez Valverde, F.M.; Balsalobre, M.; Torregrosa, N.; Molto, M.; Gomez Ramos, M.J.; Vazquez Rojas, J.L.

    2007-01-01

    Spontaneous adrenal hemorrhage is a very rare but serious disorder of the adrenal gland that can require emergent treatment. We report on a 42-year-old man who underwent selective angiography for diagnosis and treatment of retroperitoneal hemorrhage from small adrenal artery aneurysm. This case gives further details about the value of transluminal artery embolization in the management of visceral aneurysm rupture

  17. Individual differences in spontaneous analogical transfer.

    Science.gov (United States)

    Kubricht, James R; Lu, Hongjing; Holyoak, Keith J

    2017-05-01

    Research on analogical problem solving has shown that people often fail to spontaneously notice the relevance of a semantically remote source analog when solving a target problem, although they are able to form mappings and derive inferences when given a hint to recall the source. Relatively little work has investigated possible individual differences that predict spontaneous transfer, or how such differences may interact with interventions that facilitate transfer. In this study, fluid intelligence was measured for participants in an analogical problem-solving task, using an abridged version of the Raven's Progressive Matrices (RPM) test. In two experiments, we systematically compared the effect of augmenting verbal descriptions of the source with animations or static diagrams. Solution rates to Duncker's radiation problem were measured across varying source presentation conditions, and participants' understanding of the relevant source material was assessed. The pattern of transfer was best fit by a moderated mediation model: the positive impact of fluid intelligence on spontaneous transfer was mediated by its influence on source comprehension; however, this path was in turn modulated by provision of a supplemental animation via its influence on comprehension of the source. Animated source depictions were most beneficial in facilitating spontaneous transfer for those participants with low scores on the fluid intelligence measure.

  18. Spontaneous regression of a mandibular arteriovenous malformation

    Directory of Open Access Journals (Sweden)

    Scott B. Raymond, MD, PhD

    2015-06-01

    Full Text Available Mandibular arteriovenous malformations (AVMs are rare lesions that may initially present as catastrophic bleeding during dental surgical procedures. Owing to the significant risk of bleeding, most mandibular AVMs are treated definitively by resection or embolization. In this report, we describe a mandibular AVM that spontaneously regressed after biopsy.

  19. Unified gauge theories with spontaneous symmetry breaking

    International Nuclear Information System (INIS)

    MacDowell, S.W.

    1975-01-01

    Unified gauge theories with spontaneous symmetry breaking are studied with a view to renormalize quantum field theory. Georgi-Glashow and Weinberg-Salam models to unify weak and electromagnetic interactions are discussed in detail. Gauge theories of strong interactions are also considered [pt

  20. Influence of spontaneous fermentation on some quality ...

    African Journals Online (AJOL)

    Spontaneous fermentation has been identified to improve the quality characteristics of foods derived from them. When combined with cowpea fortification and nixtamalization, it is expected to improve the nutritional, functional, physico- chemical and sensory qualities of maize based foods thereby improving the qualities as ...

  1. Maternal Factors Associated With Early Spontaneous Singleton ...

    African Journals Online (AJOL)

    Background: Knowledge of the maternal factors predisposing to preterm deliveries should affect the anticipatory care of mothers at risk of delivering preterm babies and improve perinatal outcome. Objective: To determine the maternal socio-biological characteristics associated with the delivery of early spontaneous ...

  2. PERIODIC-SOLUTIONS IN SPONTANEOUSLY BROKEN THEORIES

    NARCIS (Netherlands)

    BRIHAYE, Y; KUNZ, J

    A class of spontaneously broken field theories is proposed, and the occurrence of their periodic, classical solutions is investigated in detail. The emergence of multiple solutions is observed, their normal modes of oscillation are studied, and the bifurcations of the classical energy functional are

  3. Spontaneous sensorimotor coupling with multipart music.

    Science.gov (United States)

    Hurley, Brian K; Martens, Peter A; Janata, Petr

    2014-08-01

    Music often evokes spontaneous movements in listeners that are synchronized with the music, a phenomenon that has been characterized as being in "the groove." However, the musical factors that contribute to listeners' initiation of stimulus-coupled action remain unclear. Evidence suggests that newly appearing objects in auditory scenes orient listeners' attention, and that in multipart music, newly appearing instrument or voice parts can engage listeners' attention and elicit arousal. We posit that attentional engagement with music can influence listeners' spontaneous stimulus-coupled movement. Here, 2 experiments-involving participants with and without musical training-tested the effect of staggering instrument entrances across time and varying the number of concurrent instrument parts within novel multipart music on listeners' engagement with the music, as assessed by spontaneous sensorimotor behavior and self-reports. Experiment 1 assessed listeners' moment-to-moment ratings of perceived groove, and Experiment 2 examined their spontaneous tapping and head movements. We found that, for both musically trained and untrained participants, music with more instruments led to higher ratings of perceived groove, and that music with staggered instrument entrances elicited both increased sensorimotor coupling and increased reports of perceived groove. Although untrained participants were more likely to rate music as higher in groove, trained participants showed greater propensity for tapping along, and they did so more accurately. The quality of synchronization of head movements with the music, however, did not differ as a function of training. Our results shed new light on the relationship between complex musical scenes, attention, and spontaneous sensorimotor behavior.

  4. Optimal Taxation and Social Insurance in a Lifetime Perspective

    DEFF Research Database (Denmark)

    Bovenberg, A. Lans; Sørensen, Peter Birch

    -transfer system does not provide full disability insurance. By offering imperfect insurance and structuring disability benefits so as to enable workers to insure against disability by working harder, social insurance is designed to offset the distortionary impact of the redistributive labor income tax on labor...... to insure (ex ante) against skill heterogeneity as well as disability risk. Optimal disability benefits rise with previous earnings so that public transfers depend not only on current earnings but also on earnings in the past. Hence, lifetime taxation rather than annual taxation is optimal. The optimal tax......Advances in information technology have improved the administrative feasibility of redistribution based on lifetime earnings recorded at the time of retirement. We study optimal lifetime income taxation and social insurance in an economy in which redistributive taxation and social insurance serve...

  5. Lifetime risk of renal replacement therapy in Europe

    DEFF Research Database (Denmark)

    van den Brand, Jan A J G; Pippias, Maria; Stel, Vianda S

    2017-01-01

    Background: Upcoming KDIGO guidelines for the evaluation of living kidney donors are expected to move towards a personal risk-based evaluation of potential donors. We present the age and sex-specific lifetime risk of renal replacement therapy (RRT) for end-stage renal disease in 10 European......, and used these to estimate the cumulative incidence of RRT, adjusting for competing mortality risk. Results: Lifetime risk of RRT varied from 0.44% to 2.05% at age 20 years and from 0.17% to 1.59% at age 70 years across countries, and was twice as high in men as in women. Lifetime RRT risk decreased...... in the evaluation and communication of the risk of RRT for potential living kidney donors....

  6. An improved $\\pi$K atom lifetime measurement

    CERN Document Server

    Yazkov, V

    2016-01-01

    This note describes details of analysis of data samples collected by DIRAC experiment on a Pt target in 2007 and Ni targets in 2008–2010 in order to estimate the lifetime of πK atoms. Experimental results consist of eight distinct data samples: both charge combinations ( π + K − and K + π − atoms) obtained in different experimental conditions corresponding to each year of data taking. Estimations of systematic errors are presented. Taking into account both statistical and systematic uncertainties, the lifetime of πK atoms is estimated by the maximum likelihood method. The above sample comprises the total statistics, available for the analysis, thus the improvement over the previous estimation [1,3] of the πK atom lifetime is achieved.

  7. Intrinsic spin lifetimes in GaAs (110) quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Georg; Roemer, Michael; Huebner, Jens; Oestreich, Michael [Institut fuer Festkoerperphysik, Gottfried Wilhelm Leibniz Universitaet Hannover, Hannover (Germany); Schuh, Dieter; Wegscheider, Werner [Institut fuer Experimentelle und Angewandte Physik, Universitaet Regensburg (Germany)

    2009-07-01

    GaAs(110) quantum wells attract great attention due to the long spin lifetime for electron spins along the growth axis and are, therefore, of interest for future spin based optoelectronic devices. At low temperatures, optical injection of a finite spin polarization yields strongly enhanced spin dephasing due to the Bir Aronov Pikus mechanism that arises from the exchange interaction between electrons and holes. Thus, the intrinsic spin lifetime in GaAs(110) quantum wells has been unknown. In this work, the non-demolition technique of spin noise spectroscopy, which only relies on statistical spin fluctuations, is applied to GaAs(110) quantum wells in order to measure the intrinsic spin lifetimes. Furthermore, the Brownian motion of the electrons modifies the linewidth of the measured spin noise spectra due to time of flight broadening. This effect uniquely allows to study electronic motion at thermal equilibrium.

  8. Real-time background suppression during frequency domain lifetime measurements.

    Science.gov (United States)

    Herman, Petr; Maliwal, Badri P; Lakowicz, Joseph R; Maliwal, Baldri P

    2002-10-01

    We describe real time background suppression of autofluorescence from biological samples during frequency domain or phase modulation measurements of intensity decays. For these measurements the samples were excited with a train of light pulses with widths below 1 ps. The detector was gated off for a short time period of 10 to 40 ns during and shortly after the excitation pulse. The reference signal needed for the frequency domain measurement was provided by a long-lifetime reference fluorophore which continues to emit following the off-gating pulse. Both the sample and the reference were measured under identical optical and electronic conditions avoiding the need for correction of the photomultiplier tube signal for the gating sequence. We demonstrate frequency domain background suppression using a mixture of short- and long-lifetime probes and for a long-lifetime probe in human plasma with significant autofluorescence.

  9. Simultaneous measurements of fluorescence lifetimes, anisotropy, and FRAP recovery curves

    Science.gov (United States)

    Levitt, James A.; Chung, Pei-Hua; Alibhai, Dominic R.; Suhling, Klaus

    2011-02-01

    We present fluorescence lifetime imaging (FLIM) and fluorescence anisotropy imaging along with translational diffusion measurements of living cells labelled with green fluorescent protein (GFP) recorded in a single experiment. The experimental set-up allows for time and polarization-resolved fluorescence images to be measured in every frame of a fluorescence recovery after photobleaching (FRAP) series. We have validated the method using rhodamine 123 in homogeneous solution prior to measurements of living A431 cells labelled with cdc42-GFP, for which the FRAP recovery exhibits an immobile fraction and the rotational mobility of the protein is hindered while the fluorescence lifetime fairly homogeneous across the cell. By eliminating the need for sequential measurements to extract fluorescence lifetimes and molecular diffusion coefficients we remove artefacts arising from changes in sample morphology and excessive photobleaching during sequential experiments.

  10. Multiphoton autofluorescence lifetime imaging of induced pluripotent stem cells

    Science.gov (United States)

    Uchugonova, Aisada

    2017-06-01

    The multiphoton fluorescence lifetime imaging tomograph MPTflex with its flexible 360-deg scan head, articulated arm, and tunable femtosecond laser source was employed to study induced pluripotent stem cell (iPS) cultures. Autofluorescence (AF) lifetime imaging was performed with 250-ps temporal resolution and submicron spatial resolution using time-correlated single-photon counting. The two-photon excited AF was based on the metabolic coenzymes NAD(P)H and flavin adenine dinucleotide/flavoproteins. iPS cells generated from mouse embryonic fibroblasts (MEFs) and cocultured with growth-arrested MEFs as feeder cells have been studied. Significant differences on AF lifetime signatures were identified between iPS and feeder cells as well as between their differentiating counterparts.

  11. First wall and limiter lifetime in pulsed tokamak reactors

    International Nuclear Information System (INIS)

    Ehst, D.; Majumdar, S.; Cha, Y.; Hassanein, A.

    1983-12-01

    This study concentrates on the structural integrity of certain reactor subsystems under cyclic operation to answer the question: how long a burn pulse is needed to achieve the benefits of steady-state operation. Component lifetime in the steady-state is limited by three effects: radiation damage, disruptions, and sputtering erosion. Cyclic operation modifies one of these (the number of disruptions may increase with the number of burn cycles) and introduces a fourth life limit, thermal fatigue. Our design strategy is to determine the structure and coating thicknesses which maximize component lifetime against all life limitations. After calculating disruption damage (vaporization, melting) for candidate materials we present the lifetime analysis for different structures

  12. Positron lifetime measurements on electron irradiated amorphous alloys

    International Nuclear Information System (INIS)

    Moser, P.; Hautojaervi, P.; Chamberod, A.; Yli-Kauppila, J.; Van Zurk, R.

    1981-08-01

    Great advance in understanding the nature of point defects in crystalline metals has been achieved by employing positron annihilation technique. Positrons detect vacancy-type defects and the lifetime value of trapped positrons gives information on the size of submicroscopic vacancy aglomerates and microvoids. In this paper it is shown that low-temperature electron irradiations can result in a considerable increase in the positron lifetimes in various amorphous alloys because of the formation of vacancy-like defects which, in addition of the pre-existing holes, are able to trap positrons. Studied amorphous alloys were Fe 80 B 20 , Pd 80 Si 20 , Cu 50 Ti 50 , and Fe 40 Ni 40 P 14 B 6 . Electron irradiations were performed with 3 MeV electrons at 20 K to doses around 10 19 e - /cm 2 . After annealing positron lifetime spectra were measured at 77 K

  13. Optimal Taxation and Social Insurance in a Lifetime Perspective

    DEFF Research Database (Denmark)

    Bovenberg, A. Lans; Sørensen, Peter Birch

    Advances in information technology have improved the administrative feasibility of redistribution based on lifetime earnings recorded at the time of retirement. We study optimal lifetime income taxation and social insurance in an economy in which redistributive taxation and social insurance serve...... to insure (ex ante) against skill heterogeneity as well as disability risk. Optimal disability benefits rise with previous earnings so that public transfers depend not only on current earnings but also on earnings in the past. Hence, lifetime taxation rather than annual taxation is optimal. The optimal tax......-transfer system does not provide full disability insurance. By offering imperfect insurance and structuring disability benefits so as to enable workers to insure against disability by working harder, social insurance is designed to offset the distortionary impact of the redistributive labor income tax on labor...

  14. Position lifetime changes during the fatigue of Cu

    International Nuclear Information System (INIS)

    Alexopoulos, P.; Byrne, J.G.

    1978-01-01

    Positron lifetime and x-ray particle size measurements were made during cyclic fatigue of each of cold-rolled and variously annealed Cu. Fatigue cycling of initially hard Cu caused the average positron lifetime and x-ray particle size to change in opposite senses, the former decreasing and the latter increasing, indicating decreasing defect density and an increase in the average subgrain size. Fatigue cycling of Cu initially in the annealed condition caused the mean positron lifetime to increase and the x-ray particle size to decrease, indicating an increase in the defect density and a decrease in the average subgrain size. Vacancy generation and condensation are verified as early fatigue mechanisms during fatigue in the absence of significant change of the dislocation cell structure

  15. Strong Photonic-Band-Gap Effect on the Spontaneous Emission in 3D Lead Halide Perovskite Photonic Crystals.

    Science.gov (United States)

    Zhou, Xue; Li, Mingzhu; Wang, Kang; Li, Huizeng; Li, Yanan; Li, Chang; Yan, Yongli; Zhao, Yongsheng; Song, Yanlin

    2018-03-25

    Stimulated emission in perovskite-embedded polymer opal structures is investigated. A polymer opal structure is filled with a perovskite, and perovskite photonic crystals are prepared. The spontaneous emission of the perovskite embedded in the polymer opal structures exhibits clear signatures of amplified spontaneous emission (ASE) via gain modulation. The difference in refractive-index contrast between the perovskite and the polymer opal is large enough for retaining photonic-crystals properties. The photonic band gap has a strong effect on the fluorescence emission intensity and lifetime. The stimulated emission spectrum exhibits a narrow ASE rather than a wide fluorescence peak in the thin film. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Measurement of Bs0 and Ds- Meson Lifetimes

    Science.gov (United States)

    Aaij, R.; Adeva, B.; Adinolfi, M.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M.; Ali, S.; Alkhazov, G.; Alvarez Cartelle, P.; Alves, A. A.; Amato, S.; Amerio, S.; Amhis, Y.; An, L.; Anderlini, L.; Andreassi, G.; Andreotti, M.; Andrews, J. E.; Appleby, R. B.; Archilli, F.; d'Argent, P.; Arnau Romeu, J.; Artamonov, A.; Artuso, M.; Aslanides, E.; Auriemma, G.; Baalouch, M.; Babuschkin, I.; Bachmann, S.; Back, J. J.; Badalov, A.; Baesso, C.; Baker, S.; Balagura, V.; Baldini, W.; Baranov, A.; Barlow, R. J.; Barschel, C.; Barsuk, S.; Barter, W.; Baryshnikov, F.; Baszczyk, M.; Batozskaya, V.; Batsukh, B.; Battista, V.; Bay, A.; Beaucourt, L.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Beiter, A.; Bel, L. J.; Bellee, V.; Belloli, N.; Belous, K.; Belyaev, I.; Ben-Haim, E.; Bencivenni, G.; Benson, S.; Beranek, S.; Berezhnoy, A.; Bernet, R.; Bertolin, A.; Betancourt, C.; Betti, F.; Bettler, M.-O.; van Beuzekom, M.; Bezshyiko, Ia.; Bifani, S.; Billoir, P.; Birnkraut, A.; Bitadze, A.; Bizzeti, A.; Blake, T.; Blanc, F.; Blouw, J.; Blusk, S.; Bocci, V.; Boettcher, T.; Bondar, A.; Bondar, N.; Bonivento, W.; Bordyuzhin, I.; Borgheresi, A.; Borghi, S.; Borisyak, M.; Borsato, M.; Bossu, F.; Boubdir, M.; Bowcock, T. J. V.; Bowen, E.; Bozzi, C.; Braun, S.; Britton, T.; Brodzicka, J.; Buchanan, E.; Burr, C.; Bursche, A.; Buytaert, J.; Cadeddu, S.; Calabrese, R.; Calvi, M.; Calvo Gomez, M.; Camboni, A.; Campana, P.; Campora Perez, D. H.; Capriotti, L.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carniti, P.; Carson, L.; Carvalho Akiba, K.; Casse, G.; Cassina, L.; Castillo Garcia, L.; Cattaneo, M.; Cavallero, G.; Cenci, R.; Chamont, D.; Charles, M.; Charpentier, Ph.; Chatzikonstantinidis, G.; Chefdeville, M.; Chen, S.; Cheung, S.-F.; Chobanova, V.; Chrzaszcz, M.; Chubykin, A.; Cid Vidal, X.; Ciezarek, G.; Clarke, P. E. L.; Clemencic, M.; Cliff, H. V.; Closier, J.; Coco, V.; Cogan, J.; Cogneras, E.; Cogoni, V.; Cojocariu, L.; Collins, P.; Comerma-Montells, A.; Contu, A.; Cook, A.; Coombs, G.; Coquereau, S.; Corti, G.; Corvo, M.; Costa Sobral, C. M.; Couturier, B.; Cowan, G. A.; Craik, D. C.; Crocombe, A.; Cruz Torres, M.; Cunliffe, S.; Currie, R.; D'Ambrosio, C.; Da Cunha Marinho, F.; Dall'Occo, E.; Dalseno, J.; David, P. N. Y.; Davis, A.; De Bruyn, K.; De Capua, S.; De Cian, M.; De Miranda, J. M.; De Paula, L.; De Serio, M.; De Simone, P.; Dean, C. T.; Decamp, D.; Deckenhoff, M.; Del Buono, L.; Dembinski, H.-P.; Demmer, M.; Dendek, A.; Derkach, D.; Deschamps, O.; Dettori, F.; Dey, B.; Di Canto, A.; Di Nezza, P.; Dijkstra, H.; Dordei, F.; Dorigo, M.; Dosil Suárez, A.; Dovbnya, A.; Dreimanis, K.; Dufour, L.; Dujany, G.; Dungs, K.; Durante, P.; Dzhelyadin, R.; Dziewiecki, M.; Dziurda, A.; Dzyuba, A.; Déléage, N.; Easo, S.; Ebert, M.; Egede, U.; Egorychev, V.; Eidelman, S.; Eisenhardt, S.; Eitschberger, U.; Ekelhof, R.; Eklund, L.; Ely, S.; Esen, S.; Evans, H. M.; Evans, T.; Falabella, A.; Farley, N.; Farry, S.; Fay, R.; Fazzini, D.; Ferguson, D.; Fernandez, G.; Fernandez Prieto, A.; Ferrari, F.; Ferreira Rodrigues, F.; Ferro-Luzzi, M.; Filippov, S.; Fini, R. A.; Fiore, M.; Fiorini, M.; Firlej, M.; Fitzpatrick, C.; Fiutowski, T.; Fleuret, F.; Fohl, K.; Fontana, M.; Fontanelli, F.; Forshaw, D. C.; Forty, R.; Franco Lima, V.; Frank, M.; Frei, C.; Fu, J.; Funk, W.; Furfaro, E.; Färber, C.; Gallas Torreira, A.; Galli, D.; Gallorini, S.; Gambetta, S.; Gandelman, M.; Gandini, P.; Gao, Y.; Garcia Martin, L. M.; García Pardiñas, J.; Garra Tico, J.; Garrido, L.; Garsed, P. J.; Gascon, D.; Gaspar, C.; Gavardi, L.; Gazzoni, G.; Gerick, D.; Gersabeck, E.; Gersabeck, M.; Gershon, T.; Ghez, Ph.; Gianı, S.; Gibson, V.; Girard, O. G.; Giubega, L.; Gizdov, K.; Gligorov, V. V.; Golubkov, D.; Golutvin, A.; Gomes, A.; Gorelov, I. V.; Gotti, C.; Govorkova, E.; Graciani Diaz, R.; Granado Cardoso, L. A.; Graugés, E.; Graverini, E.; Graziani, G.; Grecu, A.; Greim, R.; Griffith, P.; Grillo, L.; Gruberg Cazon, B. R.; Grünberg, O.; Gushchin, E.; Guz, Yu.; Gys, T.; Göbel, C.; Hadavizadeh, T.; Hadjivasiliou, C.; Haefeli, G.; Haen, C.; Haines, S. C.; Hamilton, B.; Han, X.; Hansmann-Menzemer, S.; Harnew, N.; Harnew, S. T.; Harrison, J.; Hatch, M.; He, J.; Head, T.; Heister, A.; Hennessy, K.; Henrard, P.; Henry, L.; van Herwijnen, E.; Heß, M.; Hicheur, A.; Hill, D.; Hombach, C.; Hopchev, H.; Huard, Z.-C.; Hulsbergen, W.; Humair, T.; Hushchyn, M.; Hutchcroft, D.; Idzik, M.; Ilten, P.; Jacobsson, R.; Jalocha, J.; Jans, E.; Jawahery, A.; Jiang, F.; John, M.; Johnson, D.; Jones, C. R.; Joram, C.; Jost, B.; Jurik, N.; Kandybei, S.; Karacson, M.; Kariuki, J. M.; Karodia, S.; Kecke, M.; Kelsey, M.; Kenzie, M.; Ketel, T.; Khairullin, E.; Khanji, B.; Khurewathanakul, C.; Kirn, T.; Klaver, S.; Klimaszewski, K.; Klimkovich, T.; Koliiev, S.; Kolpin, M.; Komarov, I.; Kopecna, R.; Koppenburg, P.; Kosmyntseva, A.; Kotriakhova, S.; Kozachuk, A.; Kozeiha, M.; Kravchuk, L.; Kreps, M.; Krokovny, P.; Kruse, F.; Krzemien, W.; Kucewicz, W.; Kucharczyk, M.; Kudryavtsev, V.; Kuonen, A. K.; Kurek, K.; Kvaratskheliya, T.; Lacarrere, D.; Lafferty, G.; Lai, A.; Lanfranchi, G.; Langenbruch, C.; Latham, T.; Lazzeroni, C.; Le Gac, R.; van Leerdam, J.; Leflat, A.; Lefrançois, J.; Lefèvre, R.; Lemaitre, F.; Lemos Cid, E.; Leroy, O.; Lesiak, T.; Leverington, B.; Li, T.; Li, Y.; Li, Z.; Likhomanenko, T.; Lindner, R.; Lionetto, F.; Liu, X.; Loh, D.; Longstaff, I.; Lopes, J. H.; Lucchesi, D.; Lucio Martinez, M.; Luo, H.; Lupato, A.; Luppi, E.; Lupton, O.; Lusiani, A.; Lyu, X.; Machefert, F.; Maciuc, F.; Maev, O.; Maguire, K.; Malde, S.; Malinin, A.; Maltsev, T.; Manca, G.; Mancinelli, G.; Manning, P.; Maratas, J.; Marchand, J. F.; Marconi, U.; Marin Benito, C.; Marinangeli, M.; Marino, P.; Marks, J.; Martellotti, G.; Martin, M.; Martinelli, M.; Martinez Santos, D.; Martinez Vidal, F.; Martins Tostes, D.; Massacrier, L. M.; Massafferri, A.; Matev, R.; Mathad, A.; Mathe, Z.; Matteuzzi, C.; Mauri, A.; Maurice, E.; Maurin, B.; Mazurov, A.; McCann, M.; McNab, A.; McNulty, R.; Meadows, B.; Meier, F.; Melnychuk, D.; Merk, M.; Merli, A.; Michielin, E.; Milanes, D. A.; Minard, M.-N.; Mitzel, D. S.; Mogini, A.; Molina Rodriguez, J.; Monroy, I. A.; Monteil, S.; Morandin, M.; Morello, M. J.; Morgunova, O.; Moron, J.; Morris, A. B.; Mountain, R.; Muheim, F.; Mulder, M.; Mussini, M.; Müller, D.; Müller, J.; Müller, K.; Müller, V.; Naik, P.; Nakada, T.; Nandakumar, R.; Nandi, A.; Nasteva, I.; Needham, M.; Neri, N.; Neubert, S.; Neufeld, N.; Neuner, M.; Nguyen, T. D.; Nguyen-Mau, C.; Nieswand, S.; Niet, R.; Nikitin, N.; Nikodem, T.; Nogay, A.; Novoselov, A.; O'Hanlon, D. P.; Oblakowska-Mucha, A.; Obraztsov, V.; Ogilvy, S.; Oldeman, R.; Onderwater, C. J. G.; Ossowska, A.; Otalora Goicochea, J. M.; Owen, P.; Oyanguren, A.; Pais, P. R.; Palano, A.; Palutan, M.; Papanestis, A.; Pappagallo, M.; Pappalardo, L. L.; Pappenheimer, C.; Parker, W.; Parkes, C.; Passaleva, G.; Pastore, A.; Patel, M.; Patrignani, C.; Pearce, A.; Pellegrino, A.; Penso, G.; Pepe Altarelli, M.; Perazzini, S.; Perret, P.; Pescatore, L.; Petridis, K.; Petrolini, A.; Petrov, A.; Petruzzo, M.; Picatoste Olloqui, E.; Pietrzyk, B.; Pikies, M.; Pinci, D.; Pistone, A.; Piucci, A.; Placinta, V.; Playfer, S.; Plo Casasus, M.; Poikela, T.; Polci, F.; Poli Lener, M.; Poluektov, A.; Polyakov, I.; Polycarpo, E.; Pomery, G. J.; Ponce, S.; Popov, A.; Popov, D.; Popovici, B.; Poslavskii, S.; Potterat, C.; Price, E.; Prisciandaro, J.; Prouve, C.; Pugatch, V.; Puig Navarro, A.; Punzi, G.; Qian, C.; Qian, W.; Quagliani, R.; Rachwal, B.; Rademacker, J. H.; Rama, M.; Ramos Pernas, M.; Rangel, M. S.; Raniuk, I.; Ratnikov, F.; Raven, G.; Redi, F.; Reichert, S.; dos Reis, A. C.; Remon Alepuz, C.; Renaudin, V.; Ricciardi, S.; Richards, S.; Rihl, M.; Rinnert, K.; Rives Molina, V.; Robbe, P.; Rodrigues, A. B.; Rodrigues, E.; Rodriguez Lopez, J. A.; Rodriguez Perez, P.; Rogozhnikov, A.; Roiser, S.; Rollings, A.; Romanovskiy, V.; Romero Vidal, A.; Ronayne, J. W.; Rotondo, M.; Rudolph, M. S.; Ruf, T.; Ruiz Valls, P.; Saborido Silva, J. J.; Sadykhov, E.; Sagidova, N.; Saitta, B.; Salustino Guimaraes, V.; Sanchez Gonzalo, D.; Sanchez Mayordomo, C.; Sanmartin Sedes, B.; Santacesaria, R.; Santamarina Rios, C.; Santimaria, M.; Santovetti, E.; Sarti, A.; Satriano, C.; Satta, A.; Saunders, D. M.; Savrina, D.; Schael, S.; Schellenberg, M.; Schiller, M.; Schindler, H.; Schlupp, M.; Schmelling, M.; Schmelzer, T.; Schmidt, B.; Schneider, O.; Schopper, A.; Schreiner, H. F.; Schubert, K.; Schubiger, M.; Schune, M.-H.; Schwemmer, R.; Sciascia, B.; Sciubba, A.; Semennikov, A.; Sergi, A.; Serra, N.; Serrano, J.; Sestini, L.; Seyfert, P.; Shapkin, M.; Shapoval, I.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, V.; Siddi, B. G.; Silva Coutinho, R.; Silva de Oliveira, L.; Simi, G.; Simone, S.; Sirendi, M.; Skidmore, N.; Skwarnicki, T.; Smith, E.; Smith, I. T.; Smith, J.; Smith, M.; Soares Lavra, l.; Sokoloff, M. D.; Soler, F. J. P.; Souza De Paula, B.; Spaan, B.; Spradlin, P.; Sridharan, S.; Stagni, F.; Stahl, M.; Stahl, S.; Stefko, P.; Stefkova, S.; Steinkamp, O.; Stemmle, S.; Stenyakin, O.; Stevens, H.; Stoica, S.; Stone, S.; Storaci, B.; Stracka, S.; Stramaglia, M. E.; Straticiuc, M.; Straumann, U.; Sun, L.; Sutcliffe, W.; Swientek, K.; Syropoulos, V.; Szczekowski, M.; Szumlak, T.; T'Jampens, S.; Tayduganov, A.; Tekampe, T.; Tellarini, G.; Teubert, F.; Thomas, E.; van Tilburg, J.; Tilley, M. J.; Tisserand, V.; Tobin, M.; Tolk, S.; Tomassetti, L.; Tonelli, D.; Topp-Joergensen, S.; Toriello, F.; Tourinho Jadallah Aoude, R.; Tournefier, E.; Tourneur, S.; Trabelsi, K.; Traill, M.; Tran, M. T.; Tresch, M.; Trisovic, A.; Tsaregorodtsev, A.; Tsopelas, P.; Tully, A.; Tuning, N.; Ukleja, A.; Ustyuzhanin, A.; Uwer, U.; Vacca, C.; Vagnoni, V.; Valassi, A.; Valat, S.; Valenti, G.; Vazquez Gomez, R.; Vazquez Regueiro, P.; Vecchi, S.; van Veghel, M.; Velthuis, J. J.; Veltri, M.; Veneziano, G.; Venkateswaran, A.; Verlage, T. A.; Vernet, M.; Vesterinen, M.; Viana Barbosa, J. V.; Viaud, B.; Vieira, D.; Vieites Diaz, M.; Viemann, H.; Vilasis-Cardona, X.; Vitti, M.; Volkov, V.; Vollhardt, A.; Voneki, B.; Vorobyev, A.; Vorobyev, V.; Voß, C.; de Vries, J. A.; Vázquez Sierra, C.; Waldi, R.; Wallace, C.; Wallace, R.; Walsh, J.; Wang, J.; Ward, D. R.; Wark, H. M.; Watson, N. K.; Websdale, D.; Weiden, A.; Whitehead, M.; Wicht, J.; Wilkinson, G.; Wilkinson, M.; Williams, M.; Williams, M. P.; Williams, M.; Williams, T.; Wilson, F. F.; Wimberley, J.; Winn, M. A.; Wishahi, J.; Wislicki, W.; Witek, M.; Wormser, G.; Wotton, S. A.; Wraight, K.; Wyllie, K.; Xie, Y.; Xing, Z.; Xu, Z.; Yang, Z.; Yang, Z.; Yao, Y.; Yin, H.; Yu, J.; Yuan, X.; Yushchenko, O.; Zarebski, K. A.; Zavertyaev, M.; Zhang, L.; Zhang, Y.; Zhelezov, A.; Zheng, Y.; Zhu, X.; Zhukov, V.; Zucchelli, S.; LHCb Collaboration

    2017-09-01

    We report on a measurement of the flavor-specific Bs0 lifetime and of the Ds- lifetime using proton-proton collisions at center-of-mass energies of 7 and 8 TeV, collected by the LHCb experiment and corresponding to 3.0 fb-1 of integrated luminosity. Approximately 407 000 Bs0→Ds(*)-μ+νμ decays are partially reconstructed in the K+K-π-μ+ final state. The Bs0 and Ds- natural widths are determined using, as a reference, kinematically similar B0→D(*)-μ+νμ decays reconstructed in the same final state. The resulting differences between widths of Bs0 and B0 mesons and of Ds- and D- mesons are ΔΓ(B )=-0.0115 ±0.0053 (stat ) ±0.0041 (syst ) ps-1 and ΔΓ(D )=1.0131 ±0.0117 (stat ) ±0.0065 (syst ) ps-1, respectively. Combined with the known B0 and D- lifetimes, these yield the flavor-specific Bs0 lifetime, τBs 0 fs =1.547 ±0.013 (stat ) ±0.010 (syst ) ±0.004 (τB) ps and the Ds- lifetime, τDs-=0.5064 ±0.0030 (stat ) ±0.0017 (syst ) ±0.0017 (τD) ps . The last uncertainties originate from the limited knowledge of the B0 and D- lifetimes. The results improve upon current determinations.

  17. Lifetime Economic Burden of Rape Among U.S. Adults.

    Science.gov (United States)

    Peterson, Cora; DeGue, Sarah; Florence, Curtis; Lokey, Colby N

    2017-06-01

    This study estimated the per-victim U.S. lifetime cost of rape. Data from previous studies was combined with current administrative data and 2011 U.S. National Intimate Partner and Sexual Violence Survey data in a mathematical model. Rape was defined as any lifetime completed or attempted forced penetration or alcohol- or drug-facilitated penetration, measured among adults not currently institutionalized. Costs included attributable impaired health, lost productivity, and criminal justice costs from the societal perspective. Average age at first rape was assumed to be 18 years. Future costs were discounted by 3%. The main outcome measures were the average per-victim (female and male) and total population discounted lifetime cost of rape. Secondary outcome measures were marginal outcome probabilities among victims (e.g., suicide attempt) and perpetrators (e.g., incarceration) and associated costs. Analysis was conducted in 2016. The estimated lifetime cost of rape was $122,461 per victim, or a population economic burden of nearly $3.1 trillion (2014 U.S. dollars) over victims' lifetimes, based on data indicating >25 million U.S. adults have been raped. This estimate included $1.2 trillion (39% of total) in medical costs; $1.6 trillion (52%) in lost work productivity among victims and perpetrators; $234 billion (8%) in criminal justice activities; and $36 billion (1%) in other costs, including victim property loss or damage. Government sources pay an estimated $1 trillion (32%) of the lifetime economic burden. Preventing sexual violence could avoid substantial costs for victims, perpetrators, healthcare payers, employers, and government payers. These findings can inform evaluations of interventions to reduce sexual violence. Published by Elsevier Inc.

  18. Mesh adaptation technique for Fourier-domain fluorescence lifetime imaging

    International Nuclear Information System (INIS)

    Soloviev, Vadim Y.

    2006-01-01

    A novel adaptive mesh technique in the Fourier domain is introduced for problems in fluorescence lifetime imaging. A dynamical adaptation of the three-dimensional scheme based on the finite volume formulation reduces computational time and balances the ill-posed nature of the inverse problem. Light propagation in the medium is modeled by the telegraph equation, while the lifetime reconstruction algorithm is derived from the Fredholm integral equation of the first kind. Stability and computational efficiency of the method are demonstrated by image reconstruction of two spherical fluorescent objects embedded in a tissue phantom

  19. Weighted oscillator strengths and lifetimes for the S VII spectrum

    International Nuclear Information System (INIS)

    Borges, F.O.; Cavalcanti, G.H.; Trigueiros, A.G.; Jupen, C.

    2004-01-01

    The weighted oscillator strengths (gf) and the lifetimes presented in this work were carried out in a multiconfiguration Hartree-Fock relativistic approach. In this calculation, the electrostatic parameters were optimized by a least-squares procedure, in order to improve the adjustment to experimental energy levels. This method produces gf-values that are in better agreement with intensity observations and lifetime values that are closer to the experimental ones. In this work, we presented all the experimentally known electric dipole S VII spectral lines

  20. MULTI-OBJECTIVE ONLINE OPTIMIZATION OF BEAM LIFETIME AT APS

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Yipeng

    2017-06-25

    In this paper, online optimization of beam lifetime at the APS (Advanced Photon Source) storage ring is presented. A general genetic algorithm (GA) is developed and employed for some online optimizations in the APS storage ring. Sextupole magnets in 40 sectors of the APS storage ring are employed as variables for the online nonlinear beam dynamics optimization. The algorithm employs several optimization objectives and is designed to run with topup mode or beam current decay mode. Up to 50\\% improvement of beam lifetime is demonstrated, without affecting the transverse beam sizes and other relevant parameters. In some cases, the top-up injection efficiency is also improved.

  1. Lifetimes and electromagnetic transition strengths in 155Dy

    Science.gov (United States)

    Petkov, P.; Yavahchova, M. S.; Möller, O.; Dewald, A.; Tonev, D.; Saha, B.; Fitzler, A.; Jessen, K.; Klug, T.; Heinze, S.; Jolie, J.; von Brentano, P.; Goutev, N.; Bazzacco, D.; Ur, C. A.; Farnea, E.; Axiotis, M.; Lunardi, S.; de Angelis, G.; Napoli, D. R.; Marginean, N.; Martinez, T.; Caprio, M. A.

    2013-09-01

    Recoil distance Doppler-shift and Doppler-shift attenuation lifetime measurements were carried out for levels in 155Dy through the coincident detection of γ rays. Twenty-six lifetimes, most of them for the first time, were determined using the differential decay curve method for the analysis of the data. At low and medium spins, particle-plus-triaxial-rotor calculations reveal different quadrupole deformations for the one-quasineutron bands in this transitional nucleus. At high spin, the reduced B(E2) transition probabilities confirm with a better precision the results of a previous study implying decreased collectivity with increasing spin.

  2. Lifetime estimates for sterilizable silver-zinc battery separators

    Science.gov (United States)

    Cuddihy, E. F.; Walmsley, D. E.; Moacanin, J.

    1972-01-01

    The lifetime of separator membranes currently employed in the electrolyte environment of silver-zinc batteries was estimated at 3 to 5 years. The separator membranes are crosslinked polyethylene film containing grafted poly (potassium acrylate)(PKA), the latter being the hydrophilic agent which promotes electrolyte ion transport. The lifetime was estimated by monitoring the rate of loss of PKA from the separators, caused by chemical attack of the electrolyte, and relating this loss rate to a known relationship between battery performance and PKA concentration in the separators.

  3. Lifetime measurements in sup 1 sup 4 sup 8 Gd

    CERN Document Server

    Podolyák, Z; Bizzeti-Sona, A M; Lunardi, S; Bazzacco, D; Farnea, E; Kröll, T; Lenzi, S; Petrache, C M; Rossi-Alvarez, C; Ur, C A; Dewald, A; Kasemann, D R; Klug, T; Peusquens, R; Algora, A; De Angelis, G; Gadea, A; Napoli, D R; Martínez, T

    2003-01-01

    Lifetimes of excited states in sup 1 sup 4 sup 8 Gd were measured using the recoil distance method with a plunger device coupled to the EUROBALL Ge detector array. The differential decay curve method in coincidence mode allowed the unambiguous determination of lifetimes of more than 20 excited states. The obtained transition strengths are in good agreement with the shell model calculations. The effect of the Z=64 subshell closure on the B(E2:2 sup +->0 sup +) reduced strengths above the N=82 magic number is discussed. (orig.)

  4. A measurement of Rb using a lifetime-mass tag

    Science.gov (United States)

    Barate, R.; Buskulic, D.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Lucotte, A.; Minard, M.-N.; Nief, J.-Y.; Pietrzyk, B.; Casado, M. P.; Chmeissani, M.; Comas, P.; Crespo, J. M.; Delfino, M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, Ll.; Juste, A.; Martinez, M.; Miquel, R.; Mir, Ll. M.; Orteu, S.; Padilla, C.; Park, I. C.; Pascual, A.; Perlas, J. A.; Riu, I.; Sanchez, F.; Teubert, F.; Colaleo, A.; Creanza, D.; de Palma, M.; Gelao, G.; Iaselli, G.; Maggi, G.; Maggi, M.; Marinelli, N.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Alemany, R.; Becker, U.; Bazarko, A. O.; Bright-Thomas, P.; Cattaneo, M.; Cerutti, F.; Drevermann, H.; Forty, R. W.; Frank, M.; Hagelberg, R.; Harvey, J.; Janot, P.; Jost, B.; Kneringer, E.; Knobloch, J.; Lehraus, I.; Lutters, G.; Mato, P.; Minten, A.; Moneta, L.; Pacheco, A.; Pusztaszeri, J.-F.; Ranjard, F.; Rensing, P.; Rizzo, G.; Rolandi, L.; Schlatter, D.; Schmitt, M.; Schneider, O.; Tejessy, W.; Tomalin, I. R.; Wachsmuth, H.; Wagner, A.; Ajaltouni, Z.; Barrès, A.; Boyer, C.; Falvard, A.; Ferdi, C.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Rosnet, P.; Rossignol, J.-M.; Fearnley, T.; Hansen, J. B.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Nilsson, B. S.; Rensch, B.; Wäänänen, A.; Daskalakis, G.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Siotis, I.; Vayaki, A.; Blondel, A.; Bonneaud, G.; Brient, J. C.; Bourdon, P.; Rougé, A.; Rumpf, M.; Valassi, A.; Verderi, M.; Videau, H.; Candlin, D. J.; Parsons, M. I.; Focardi, E.; Parrini, G.; Zachariadou, K.; Corden, M.; Georgiopoulos, C.; Jaffe, D. E.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Casper, D.; Chiarella, V.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Passalacqua, L.; Pepe-Altarelli, M.; Curtis, L.; Dorris, S. J.; Halley, A. W.; Knowles, I. G.; Lynch, J. G.; O'Shea, V.; Raine, C.; Scarr, J. M.; Smith, K.; Teixeira-Dias, P.; Thompson, A. S.; Thomson, E.; Thomson, F.; Turnbull, R. M.; Geweniger, C.; Graefe, G.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E. E.; Putzer, A.; Schmidt, M.; Sommer, J.; Tittel, K.; Werner, S.; Wunsch, M.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Dornan, P. J.; Girone, M.; Goodsir, S.; Martin, E. B.; Moutoussi, A.; Nash, J.; Sedgbeer, J. K.; Stacey, A. M.; Williams, M. D.; Dissertori, G.; Ghete, V. M.; Girtler, P.; Kuhn, D.; Rudolph, G.; Betteridge, A. P.; Bowdery, C. K.; Colrain, P.; Crawford, G.; Finch, A. J.; Foster, F.; Hughes, G.; Sloan, T.; Williams, M. I.; Galla, A.; Giehl, I.; Greene, A. M.; Hoffmann, C.; Jakobs, K.; Kleinknecht, K.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.-G.; van Gemmeren, P.; Zeitnitz, C.; Aubert, J. J.; Benchouk, C.; Bonissent, A.; Bujosa, G.; Calvet, D.; Carr, J.; Coyle, P.; Diaconu, C.; Etienne, F.; Konstantinidis, N.; Leroy, O.; Motsch, F.; Payre, P.; Rousseau, D.; Talby, M.; Sadouki, A.; Thulasidas, M.; Trabelsi, K.; Aleppo, M.; Ragusa, F.; Berlich, R.; Blum, W.; Brown, D.; Büscher, V.; Dietl, H.; Dydak, F.; Ganis, G.; Gotzhein, C.; Kroha, H.; Lütjens, G.; Lutz, G.; Männer, W.; Moser, H.-G.; Richter, R.; Rosado-Schlosser, A.; Schael, S.; Settles, R.; Seywerd, H.; St. Denis, R.; Stenzel, H.; Wiedenmann, W.; Wolf, G.; Boucrot, J.; Callot, O.; Chen, S.; Choi, Y.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Höcker, A.; Jacholkowska, A.; Jacquet, M.; Kim, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Nikolic, I.; Schune, M.-H.; Simion, S.; Tournefier, E.; Veillet, J.-J.; Videau, I.; Zerwas, D.; Azzurri, P.; Bagliesi, G.; Batignani, G.; Bettarini, S.; Bozzi, C.; Calderini, G.; Carpinelli, M.; Ciocci, M. A.; Ciulli, V.; dell'Orso, R.; Fantechi, R.; Ferrante, I.; Foà, L.; Forti, F.; Giassi, A.; Giorgi, M. A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Sanguinetti, G.; Sciabà, A.; Spagnolo, P.; Steinberger, J.; Tenchini, R.; Tonelli, G.; Vannini, C.; Venturi, A.; Verdini, P. G.; Blair, G. A.; Bryant, L. M.; Chambers, J. T.; Gao, Y.; Green, M. G.; Medcalf, T.; Perrodo, P.; Strong, J. A.; von Wimmersperg-Toeller, J. H.; Botterill, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Maley, P.; Norton, P. R.; Thompson, J. C.; Wright, A. E.; Bloch-Devaux, B.; Colas, P.; Emery, S.; Kozanecki, W.; Lançon, E.; Lemaire, M. C.; Locci, E.; Perez, P.; Rander, J.; Renardy, J.-F.; Roussarie, A.; Schuller, J.-P.; Schwindling, J.; Trabelsi, A.; Vallage, B.; Black, S. N.; Dann, J. H.; Johnson, R. P.; Kim, H. Y.; Litke, A. M.; McNeil, M. A.; Taylor, G.; Booth, C. N.; Boswell, R.; Brew, C. A. J.; Cartwright, S.; Combley, F.; Kelly, M. S.; Lehto, M.; Newton, W. M.; Reeve, J.; Thompson, L. F.; Böhrer, A.; Brandt, S.; Cowan, G.; Grupen, C.; Saraiva, P.; Smolik, L.; Stephan, F.; Apollonio, M.; Bosisio, L.; Della Marina, R.; Giannini, G.; Gobbo, B.; Musolino, G.; Rothberg, J.; Wasserbaech, S.; Armstrong, S. R.; Charles, E.; Elmer, P.; Ferguson, D. P. S.; Gao, Y. S.; González, S.; Greening, T. C.; Hayes, O. J.; Hu, H.; Jin, S.; McNamara, P. A.; Nachtman, J. M.; Nielsen, J.; Orejudos, W.; Pan, Y. B.; Saadi, Y.; Scott, I. J.; Walsh, J.; Wu, Sau Lan; Wu, X.; Yamartino, J. M.; Zobernig, G.

    1997-02-01

    ALEPH's published measurement of Rb = Γ(Z -> bb)/Γ(Z -> hadrons) using a lifetime tag is updated using the full LEP 1 data sample. Considerable effort has been devoted to understanding systematic effects. Charm background is better controlled by combining the lifetime tag with a tag based on the b/c hadron mass difference. Furthermore, the algorithm used to reconstruct the event primary vertex is designed so as to reduce correlations between the two hemispheres of an event. The value of Rb is measured to be 0.2167 +/- 0.0011 (stat) +/- 0.0013 (syst).

  5. Positron annihilation lifetime spectroscopy study of roller burnished magnesium alloy

    Directory of Open Access Journals (Sweden)

    Zaleski Radosław

    2015-12-01

    Full Text Available The effect of roller burnishing on Vickers’ hardness and positron lifetimes in the AZ91HP magnesium alloy was studied. The microhardness increases with an increase in the burnishing force and with a decrease in the feed. The comparison of various methods of analysis of positron annihilation lifetime (PAL spectra allowed identification of two components, which are related to solute-vacancy complexes and vacancy clusters, respectively. It was found that the increase in microhardness was related to the increase in the concentration of vacancy clusters.

  6. Measuring the Neutron Lifetime with Magnetically Trapped Ultracold Neutrons

    Science.gov (United States)

    Mumm, H. P.; Huber, M. G.; Yue, A. T.; Thompson, A. K.; Dewey, M. S.; Huffer, C. R.; Huffman, P. R.; Schelhammer, K. W.; O'Shaughnessy, C.; Coakley, K. J.

    2014-03-01

    We describe an experiment to measure the neutron lifetime using a technique with a set of systematic uncertainties largely different than those of previous measurements. In this approach, ultracold neutrons (UCN) are produced by inelastic scattering of cold (0.89 nm) neutrons in a reservoir of superfluid 4He. These neutrons are then confined using a three-dimensional magnetic trap. As the trapped neutrons beta decay, the energetic electrons produced in the decay generate scintillations in the liquid He; each decay is detectable with nearly 100 % efficiency. The neutron lifetime can be directly determined by measuring the scintillation rate as a function of time.

  7. Lifetime measurement of the 8s level in francium

    International Nuclear Information System (INIS)

    Gomez, E.; Sprouse, G.D.; Orozco, L.A.; Galvan, A. Perez

    2005-01-01

    We measure the lifetime of the 8s level of 210 Fr atoms on a magneto-optically trapped sample with time-correlated single-photon counting. The 7P 1/2 state serves as the resonant intermediate level for two-step excitation of the 8s level completed with a 1.3-μm laser. Analysis of the fluorescence decay through the 7P 3/2 level gives 53.30±0.44 ns for the 8s level lifetime

  8. Spectrum Fatigue Lifetime and Residual Strength for Fiberglass Laminates; TOPICAL

    International Nuclear Information System (INIS)

    WAHL, NEIL K.; MANDELL, JOHN F.; SAMBORSKY, DANIEL D.

    2002-01-01

    This report addresses the effects of spectrum loading on lifetime and residual strength of a typical fiberglass laminate configuration used in wind turbine blade construction. Over 1100 tests have been run on laboratory specimens under a variety of load sequences. Repeated block loading at two or more load levels, either tensile-tensile, compressive-compressive, or reversing, as well as more random standard spectra have been studied. Data have been obtained for residual strength at various stages of the lifetime. Several lifetime prediction theories have been applied to the results. The repeated block loading data show lifetimes that are usually shorter than predicted by the most widely used linear damage accumulation theory, Miner's sum. Actual lifetimes are in the range of 10 to 20 percent of predicted lifetime in many cases. Linear and nonlinear residual strength models tend to fit the data better than Miner's sum, with the nonlinear providing a better fit of the two. Direct tests of residual strength at various fractions of the lifetime are consistent with the residual strength models. Load sequencing effects are found to be insignificant. The more a spectrum deviates from constant amplitude, the more sensitive predictions are to the damage law used. The nonlinear model provided improved correlation with test data for a modified standard wind turbine spectrum. When a single, relatively high load cycle was removed, all models provided similar, though somewhat non-conservative correlation with the experimental results. Predictions for the full spectrum, including tensile and compressive loads were slightly non-conservative relative to the experimental data, and accurately captured the trend with varying maximum load. The nonlinear residual strength based prediction with a power law S-N curve extrapolation provided the best fit to the data in most cases. The selection of the constant amplitude fatigue regression model becomes important at the lower stress, higher

  9. High Efficiency Polymer Solar Cells with Long Operating Lifetimes

    KAUST Repository

    Peters, Craig H.

    2011-04-20

    Organic bulk-heterojunction solar cells comprising poly[N-9\\'-hepta-decanyl- 2,7-carbazole-alt-5,5-(4\\',7\\'-di-2-thienyl-2\\', 1\\',3\\'-benzothiadiazole) (PCDTBT) are systematically aged and demonstrate lifetimes approaching seven years, which is the longest reported lifetime for polymer solar cells. An experimental set-up is described that is capable of testing large numbers of solar cells, holding each device at its maximum power point while controlling and monitoring the temperature and light intensity. © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Long-wavelength stimulated emission and carrier lifetimes in HgCdTe-based waveguide structures with quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Rumyantsev, V. V., E-mail: rumyantsev@ipm.sci-nnov.ru; Fadeev, M. A.; Morozov, S. V.; Dubinov, A. A.; Kudryavtsev, K. E.; Kadykov, A. M. [Russian Academy of Sciences, Institute for Physics of Microstructures (Russian Federation); Tuzov, I. V. [Lobachevsky State University of Nizhny Novgorod (NNSU) (Russian Federation); Dvoretskii, S. A.; Mikhailov, N. N. [Russian Academy of Sciences, Institute for Semiconductor Physics, Siberian Branch (Russian Federation); Gavrilenko, V. I. [Novosibirsk State University (Russian Federation); Teppe, F. [Universite Montpellier II, Laboratoire Charles Coulomb (L2C) (France)

    2016-12-15

    The interband photoconductivity and photoluminescence in narrow-gap HgCdTe-based waveguide structures with quantum wells (QWs) (designed for long-wavelength stimulated emission under optical pumping) are investigated. The photoconductivity relaxation times in n-type structures reach several microseconds, due to which stimulated emission at a wavelength of 10.2 μm occurs at a low threshold pump intensity (~100 W/cm{sup 2}) at 20 K. In the p-type structures obtained by annealing (to increase the mercury vacancy concentration), even spontaneous emission from the QWs is not detected because of a dramatic decrease in the carrier lifetime with respect to Shockley–Read–Hall nonradiative recombination.

  11. Socioeconomic position and the risk of spontaneous abortion

    DEFF Research Database (Denmark)

    Norsker, Filippa Nyboe; Espenhain, Laura; rogvi, Sofie

    2012-01-01

    To investigate the relationship between different indicators of socioeconomic position and the risk of spontaneous abortion.......To investigate the relationship between different indicators of socioeconomic position and the risk of spontaneous abortion....

  12. The Lifetime of a beautiful and charming meson: Bc lifetime measured using the D0 detector

    Energy Technology Data Exchange (ETDEWEB)

    Welty-Rieger, Leah Christine [Indiana Univ., Bloomington, IN (United States)

    2008-09-01

    Using approximately 1.3 fb-1 of data collected by the D0 detector between 2002 and 2006, the lifetime of the Bc± meson is studied in the Bc± → J/Ψμ± + X final state. Using an unbinned likelihood simultaneous fit to J/Ψ + μ invariant mass and lifetime distributions, a signal of 810 ± 80(stat.) candidates is estimated and a lifetime measurement made of: τ(Bc±) = 0.448-0.036+0.038(stat) ± 0.032(sys) ps.

  13. [Bacterial vaginosis and spontaneous preterm birth].

    Science.gov (United States)

    Brabant, G

    2016-12-01

    To determine if bacterial vaginosis is a marker for risk of spontaneous preterm delivery and if its detection and treatment can reduce this risk. Consultation of the database Pubmed/Medline, Science Direct, and international guidelines of medical societies. Bacterial vaginosis (BV) is a dysbiosis resulting in an imbalance in the vaginal flora through the multiplication of anaerobic bacteria and jointly of a disappearance of well-known protective Lactobacilli. His diagnosis is based on clinical Amsel criteria and/or a Gram stain with establishment of the Nugent score. The prevalence of the BV extraordinarily varies according to ethnic and/or geographical origin (4-58 %), in France, it is close to 7 % in the first trimester of pregnancy (EL2). The link between BV and spontaneous premature delivery is low with an odds ratio between 1.5 and 2 in the most recent studies (EL3). Metronidazole or clindamycin is effective to treat BV (EL3). It is recommended to prescribe one of these antibiotics in the case of symptomatic BV (Professional Consensus). The testing associated with the treatment of BV in the global population showed no benefit in the prevention of the risk of spontaneous preterm delivery (EL2). Concerning low-risk asymptomatic population (defined by the absence of antecedent of premature delivery), it has been failed profit to track and treat the BV in the prevention of the risk of spontaneous preterm delivery (EL1). Concerning the high-risk population (defined by a history of preterm delivery), it has been failed profit to track and treat the VB in the prevention of the risk of spontaneous preterm delivery (EL3). However, in the sub population of patients with a history of preterm delivery occurred in a context of materno-fetal bacterial infection, there may be a benefit to detect and treat early and systematically genital infection, and in particular the BV (Professional Consensus). The screening and treatment of BV during pregnancy in asymptomatic low

  14. Quantum Optics with Near-Lifetime-Limited Quantum-Dot Transitions in a Nanophotonic Waveguide.

    Science.gov (United States)

    Thyrrestrup, Henri; Kiršanskė, Gabija; Le Jeannic, Hanna; Pregnolato, Tommaso; Zhai, Liang; Raahauge, Laust; Midolo, Leonardo; Rotenberg, Nir; Javadi, Alisa; Schott, Rüdiger; Wieck, Andreas D; Ludwig, Arne; Löbl, Matthias C; Söllner, Immo; Warburton, Richard J; Lodahl, Peter

    2018-03-14

    Establishing a highly efficient photon-emitter interface where the intrinsic linewidth broadening is limited solely by spontaneous emission is a key step in quantum optics. It opens a pathway to coherent light-matter interaction for, e.g., the generation of highly indistinguishable photons, few-photon optical nonlinearities, and photon-emitter quantum gates. However, residual broadening mechanisms are ubiquitous and need to be combated. For solid-state emitters charge and nuclear spin noise are of importance, and the influence of photonic nanostructures on the broadening has not been clarified. We present near-lifetime-limited linewidths for quantum dots embedded in nanophotonic waveguides through a resonant transmission experiment. It is found that the scattering of single photons from the quantum dot can be obtained with an extinction of 66 ± 4%, which is limited by the coupling of the quantum dot to the nanostructure rather than the linewidth broadening. This is obtained by embedding the quantum dot in an electrically contacted nanophotonic membrane. A clear pathway to obtaining even larger single-photon extinction is laid out; i.e., the approach enables a fully deterministic and coherent photon-emitter interface in the solid state that is operated at optical frequencies.

  15. Quantum Optics with Near-Lifetime-Limited Quantum-Dot Transitions in a Nanophotonic Waveguide

    Science.gov (United States)

    Thyrrestrup, Henri; Kiršanskė, Gabija; Le Jeannic, Hanna; Pregnolato, Tommaso; Zhai, Liang; Raahauge, Laust; Midolo, Leonardo; Rotenberg, Nir; Javadi, Alisa; Schott, Rüdiger; Wieck, Andreas D.; Ludwig, Arne; Löbl, Matthias C.; Söllner, Immo; Warburton, Richard J.; Lodahl, Peter

    2018-03-01

    Establishing a highly efficient photon-emitter interface where the intrinsic linewidth broadening is limited solely by spontaneous emission is a key step in quantum optics. It opens a pathway to coherent light-matter interaction for, e.g., the generation of highly indistinguishable photons, few-photon optical nonlinearities, and photon-emitter quantum gates. However, residual broadening mechanisms are ubiquitous and need to be combated. For solid-state emitters charge and nuclear spin noise is of importance and the influence of photonic nanostructures on the broadening has not been clarified. We present near lifetime-limited linewidths for quantum dots embedded in nanophotonic waveguides through a resonant transmission experiment. It is found that the scattering of single photons from the quantum dot can be obtained with an extinction of $66 \\pm 4 \\%$, which is limited by the coupling of the quantum dot to the nanostructure rather than the linewidth broadening. This is obtained by embedding the quantum dot in an electrically-contacted nanophotonic membrane. A clear pathway to obtaining even larger single-photon extinction is laid out, i.e., the approach enables a fully deterministic and coherent photon-emitter interface in the solid state that is operated at optical frequencies.

  16. Lifetimes of flame balls dragged by model turbulent flows: Role of velocity gradient fluctuations.

    Science.gov (United States)

    D'Angelo, Yves; Joulin, Guy

    2004-03-01

    An isolated combustion spot-known as a flame ball (FB)-is considered while it is advected by a turbulent flow of a lean premixture of such a light fuel as hydrogen. A Batchelor approximation for the surrounding Lagrangian flow is made. This in principle gives one an access to the FB lifetime t(life) and to its response to the ambiant Lagrangian rate-of-strain tensor g(t), by means of a nonlinear and forced integro-differential equation for the current FB radius. For a diagonal g(t) deduced from random Markov processes of the Ornstein-Uhlenbeck type, or linearly filtered versions thereof, extensive numerical simulations and approximate theoretical analyses agree that (i) flame balls can definitely live for much longer than their time of spontaneous expansion/collapse; (ii) large enough values of t(life) are compatible with Poisson statistics; (iii) the variations of with the characteristics of g(t) mirror the latter's statistics, more precisely that of trace(g(2)). Open problems, dealing with a nondiagonal g(t), ignition-related transients and/or collective effects, finally are evoked.

  17. The EPDS-Lifetime: assessment of lifetime prevalence and risk factors for perinatal depression in a large cohort of depressed women

    NARCIS (Netherlands)

    Meltzer-Brody, S.; Boschloo, L.; Jones, I.; Sullivan, P.F.; Penninx, B.W.J.H.

    2013-01-01

    Perinatal depression (PND) is a common complication of pregnancy and postpartum associated with significant morbidity. We had three goals: (1) to explore the performance of a new lifetime version of the Edinburgh Postnatal Depression Scale (EPDS-Lifetime) to assess lifetime prevalence of PND; (2) to

  18. F. VON HAYEK’S THEORY OF SPONTANEOUS ORDER

    Directory of Open Access Journals (Sweden)

    О. Nesterenko

    2013-04-01

    Full Text Available The essence and the genesis of spontaneous order are disclosed in the context of critical analysis of constructivism. The author’s approach to the definition of the characteristic features of the spontaneous order is proposed. The dichotomy of the order is revealed towards the economic sphere in form of spontaneous order and organization.

  19. BMI and Lifetime Changes in BMI and Cancer Mortality Risk

    NARCIS (Netherlands)

    Taghizadeh, Niloofar; Boezen, H Marike; Schouten, Jan P; Schröder, Carolien P; de Vries, Elisabeth G. E.; Vonk, Judith M

    2015-01-01

    Body Mass Index (BMI) is known to be associated with cancer mortality, but little is known about the link between lifetime changes in BMI and cancer mortality in both males and females. We studied the association of BMI measurements (at baseline, highest and lowest BMI during the study-period) and

  20. Lifetime Prevalence and Socioemotional Effects of Hearing about Community Violence

    Science.gov (United States)

    Scarpa, Angela; Hurley, Jimmy D.; Shumate, Howard W.; Haden, Sara Chiara

    2006-01-01

    This study extends findings on community violence (CV) exposure in young adults by examining the prevalence, characteristics, and socioemotional effects related to hearing about violence. Surveys of lifetime CV exposure and socioemotional outcomes were completed by 518 male and female undergraduates completed and were divided into groups with…

  1. Metallized Film Capacitor Lifetime Evaluation and Failure Mode Analysis

    CERN Document Server

    Gallay, R.

    2015-06-15

    One of the main concerns for power electronic engineers regarding capacitors is to predict their remaining lifetime in order to anticipate costly failures or system unavailability. This may be achieved using a Weibull statistical law combined with acceleration factors for the temperature, the voltage, and the humidity. This paper discusses the different capacitor failure modes and their effects and consequences.

  2. Lifetimes of charged and neutral B hadrons using event topology

    CERN Document Server

    Adam, W; Agasi, E; Ajinenko, I; Aleksan, Roy; Alekseev, G D; Allport, P P; Almehed, S; Alvsvaag, S J; Amaldi, Ugo; Amato, S; Andreazza, A; Andrieux, M L; Antilogus, P; Anykeyev, V B; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barate, R; Bardin, Dimitri Yuri; Barker, G J; Baroncelli, A; Bärring, O; Barrio, J A; Bartl, Walter; Bates, M J; Battaglia, Marco; Baubillier, M; Baudot, J; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Benvenuti, Alberto C; Berggren, M; Bertrand, D; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bloch, D; Blume, M; Blyth, S; Bocci, V; Bolognese, T; Bonesini, M; Bonivento, W; Booth, P S L; Borisov, G; Bosio, C; Bosworth, S; Botner, O; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozzo, M; Branchini, P; Brand, K D; Brenner, R A; Bricman, C; Brillault, L; Brown, R C A; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Buys, A; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Cankocak, K; Cao, F; Carena, F; Carrilho, P; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerrito, L; Chabaud, V; Charpentier, P; Chaussard, L; Chauveau, J; Checchia, P; Chelkov, G A; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Cindro, V; Collins, P; Contreras, J L; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; Dahl-Jensen, Erik; Dahm, J; D'Almagne, B; Dam, M; Damgaard, G; Daum, A; Dauncey, P D; Davenport, Martyn; Da Silva, W; Defoix, C; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; De Boeck, H; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; De Saint-Jean, C; Dijkstra, H; Di Ciaccio, Lucia; Djama, F; Dolbeau, J; Dönszelmann, M; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Dufour, Y; Dupont, F; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Elsing, M; Engel, J P; Ershaidat, N; Erzen, B; Espirito-Santo, M C; Falk, E; Fassouliotis, D; Feindt, Michael; Ferrer, A; Filippas-Tassos, A; Firestone, A; Fischer, P A; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frenkiel, P; Fries, D E C; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fürstenau, H; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gibbs, M; Gillespie, D; Gokieli, R; Golob, B; Gopal, Gian P; Gorn, L; Górski, M; Guz, Yu; Gracco, Valerio; Graziani, E; Grosdidier, G; Gunnarsson, P; Günther, M; Guy, J; Haedinger, U; Hahn, F; Hahn, M; Hahn, S; Hajduk, Z; Hallgren, A; Hamacher, K; Hao, W; Harris, F J; Hedberg, V; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Higón, E; Hilke, Hans Jürgen; Hill, T S; Holmgren, S O; Holt, P J; Holthuizen, D J; Houlden, M A; Hrubec, Josef; Huet, K; Hultqvist, K; Ioannou, P; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, Christian; Juillot, P; Kaiser, M; Kalmus, George Ernest; Kapusta, F; Karlsson, M; Karvelas, E; Katsanevas, S; Katsoufis, E C; Keränen, R; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klein, H; Klovning, A; Kluit, P M; Köhne, J H; Köne, B; Kokkinias, P; Koratzinos, M; Korcyl, K; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Kramer, P H; Krammer, Manfred; Kreuter, C; Królikowski, J; Kronkvist, I J; Krumshtein, Z; Krupinski, W; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Laktineh, I; Lamblot, S; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Lapin, V; Last, I; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leitner, R; Lemoigne, Y; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Liko, D; Lindner, R; Lipniacka, A; Lippi, I; Lörstad, B; Lokajícek, M; Loken, J G; López, J M; López-Fernandez, A; López-Aguera, M A; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Maehlum, G; Maio, A; Malychev, V; Mandl, F; Marco, J; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Maron, T; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; Medbo, J; Meroni, C; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Morettini, P; Müller, H; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Negri, P; Némécek, S; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Niss, P; Nomerotski, A; Normand, Ainsley; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Pagès, P; Palka, H; Papadopoulou, T D; Pape, L; Parkes, C; Parodi, F; Passeri, A; Pegoraro, M; Peralta, L; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Plaszczynski, S; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Prest, M; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Reale, M; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Renton, P B; Resvanis, L K; Richard, F; Richardson, J; Rídky, J; Rinaudo, G; Ripp, I; Romero, A; Roncagliolo, I; Ronchese, P; Roos, L; Rosenberg, E I; Rosso, E; Roudeau, Patrick; Rovelli, T; Rückstuhl, W; Ruhlmann-Kleider, V; Ruiz, A; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sánchez, J; Sannino, M; Schneider, H; Schyns, M A E; Sciolla, G; Scuri, F; Sedykh, Yu; Segar, A M; Seitz, A; Sekulin, R L; Shellard, R C; Siccama, I; Siegrist, P; Simonetti, S; Simonetto, F; Sissakian, A N; Sitár, B; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Squarcia, S; Stäck, H; Stanescu, C; Stapnes, Steinar; Stavitski, I; Stepaniak, K; Stichelbaut, F; Stocchi, A; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Tavernet, J P; Chikilev, O G; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Toet, D Z; Tomaradze, A G; Tomé, B; Tortora, L; Tranströmer, G; Treille, D; Trischuk, W; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Überschär, S; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; van Apeldoorn, G W; van Dam, P; Van Doninck, W K; Van Eldik, J; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Waldner, F; Wehr, A; Weierstall, M; Weilhammer, Peter; Wetherell, Alan M; Wicke, D; Wickens, J H; Wielers, M; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Woschnagg, K; Yip, K; Yushchenko, O P; Zach, F; Zacharatou-Jarlskog, C; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zhigunov, V P; Zimin, N I; Zito, M; Zontar, D; Zuberi, R; Zucchelli, G C; Zumerle, G

    1995-01-01

    The lifetimes of charged and neutral B hadrons have been measured using data collected by the DELPHI experiment at LEP between 1991 and 1993. B hadrons are tagged as jets with a secondary vertex and the charge of the B candidate is taken to be the sum of the charges of the particles in the secondary vertex. Approximately 1,434,000 multihadronic \\PZz decays yielded 1817 B hadron candidates. The B purity was estimated to be around 99.1\\pm0.3\\%, and 83\\% (70\\%) of the events measured as neutral (charged) came from neutral (charged) B's. The mean lifetimes of charged and neutral B hadrons were found to be \\TAUBC\\pm\\ERRBC\\;(stat.)\\pm\\SYSBC\\;(syst.)~ps and \\TAUBN\\pm\\ERRBN\\;(stat.)\\pm\\SYSBN\\;(syst.)~ps respectively. The ratio of their lifetimes, \\tau_{charged}/\\tau_{neutral}, was \\RAT10^{\\ERRCNP}_{\\ERRCNM}\\;(stat.)\\pm\\SYSR10\\;(syst.). By making assumptions about the \\PsB and \\PlB states, the \\PbBp and \\PbBz meson lifetimes were determined to be \\tau_{{\\rm B}^+}=\\TAUBP\\pm\\ERRBP\\;(stat.)\\pm\\ SYSBP\\;(syst.)~ps and \\tau...

  3. Determination of the average lifetime of bottom hadrons

    International Nuclear Information System (INIS)

    Althoff, M.; Braunschweig, W.; Kirschfink, F.J.; Martyn, H.U.; Rosskamp, P.; Schmitz, D.; Siebke, H.; Wallraff, W.; Hilger, E.; Kracht, T.; Krasemann, H.L.; Leu, P.; Lohrmann, E.; Pandoulas, D.; Poelz, G.; Poesnecker, K.U.; Duchovni, E.; Eisenberg, Y.; Karshon, U.; Mikenberg, G.; Mir, R.; Revel, D.; Shapira, A.; Baranko, G.; Caldwell, A.; Cherney, M.; Izen, J.M.; Mermikides, M.; Ritz, S.; Rudolph, G.; Strom, D.; Takashima, M.; Venkataramania, H.; Wicklund, E.; Wu, S.L.; Zobernig, G.

    1984-01-01

    We have determined the average lifetime of hadrons containing b quarks produced in e + e - annihilation to be tausub(B)=1.83x10 -12 s. Our method uses charged decay products from both non-leptonic and semileptonic decay modes. (orig./HSI)

  4. What Is the Optimal and Sustainable Lifetime of a Mine?

    Directory of Open Access Journals (Sweden)

    Friedrich-Wilhelm Wellmer

    2018-02-01

    Full Text Available The first stage of the circular economy, mining, is examined from the perspective of sustainability. The authors discuss how to maximize the use of phosphate rock, a primary commodity. To attract investment capital in a market economy system, a mine has to operate profitably, i.e., its lifetime must be optimized under economic conditions, for example, according to Taylor’s Rule. From a sustainability perspective, however, the lifetime should extend as long as possible and the grades mined be as low as possible. The authors examine methods for optimizing a mine’s lifetime under economic conditions according to practical experience and learning effects to optimize exploration and exploitation. With the condition of sustainability, a recently developed concept of cut-off grade for a layered phosphate deposit is examined and considerations for prolonging a mine’s lifetime are discussed. As there are big losses from the current and potential future value chains above and below the current cut-off grade, we argue that the losses and use efficiency of phosphorus are key parts of a circular economy.

  5. Carbocation lifetimes and entropy of water addition to carbocations ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 115; Issue 1. Carbocation lifetimes and entropy of water addition to carbocations dependent on their stability. V Jagannadham. Organic Volume 115 ... Author Affiliations. V Jagannadham1. Department of Chemistry, Osmania University, Hyderabad 500 007, India ...

  6. Parity lifetime of bound states in a proximitized semiconductor nanowire

    DEFF Research Database (Denmark)

    Higginbotham, Andrew Patrick; Albrecht, Sven Marian; Kirsanskas, Gediminas

    2015-01-01

    superconductor layer, yielding an isolated, proximitized nanowire segment. We identify Andreev-like bound states in the semiconductor via bias spectroscopy, determine the characteristic temperatures and magnetic fields for quasiparticle excitations, and extract a parity lifetime (poisoning time) of the bound...

  7. Precision lifetime measurements of Ar II 4p doublet levels

    International Nuclear Information System (INIS)

    Marger, D.; Schmoranzer, H.

    1990-01-01

    The lifetimes of the Ar II 4p doublet fine-structure levels 4p 2 D 0 5/2 , 4p' 2 F 0 5/2 and 4p' 2 F 0 7/2 were measured by beam-dye laser spectroscopy. The experimental uncertainty was reduced to below 1%. (orig.)

  8. Determination of Lifetimes of Carbocations in Aqueous Solution ...

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 12; Issue 6. Determination of Lifetimes of Carbocations in Aqueous Solution by Azide Clock: A Simple Physical-Organic Chemistry Experiment. V Jagannadham. Classroom Volume 12 Issue 6 June 2007 pp 76-82 ...

  9. The Effect of Polymer Pipe Weld Geometry on Creep Lifetime

    Czech Academy of Sciences Publication Activity Database

    Ševčík, Martin; Knésl, Zdeněk; Hutař, Pavel; Náhlík, Luboš

    2011-01-01

    Roč. 465, - (2011), s. 175-178 ISSN 1013-9826 R&D Projects: GA ČR GC101/09/J027 Institutional research plan: CEZ:AV0Z20410507 Keywords : creep * stress concentration factor * lifetime * triaxiality Subject RIV: JL - Materials Fatigue, Friction Mechanics

  10. Efficient redistribution of lifetime income through welfare accounts

    NARCIS (Netherlands)

    Bovenberg, A.L.; Sorensen, P.B.; Hansen, M.I.

    2012-01-01

    Compared with a conventional tax–transfer system, individual welfare accounts can redistribute lifetime incomes at a lower efficiency cost. These welfare accounts employ mandatory contributions rather than taxes to finance social transfers to people of working age. We describe a design for welfare

  11. Lifetime mental disorders and suicidal behaviour in South Africa ...

    African Journals Online (AJOL)

    This study examines the relationship between lifetime mental disorders, and subsequent suicide ideation, plans, and suicide attempts in South Africa. Method: A national survey of 4185 South African adults was conducted using the World Health Organization Composite International Diagnostic Interview (CIDI) to generate ...

  12. Precision measurement of the Λb(0) baryon lifetime.

    Science.gov (United States)

    Aaij, R; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amerio, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Andrews, J E; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Baalouch, M; Bachmann, S; Back, J J; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bauer, Th; Bay, A; Beddow, J; Bedeschi, F; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Burducea, I; Bursche, A; Busetto, G; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Castillo Garcia, L; Cattaneo, M; Cauet, Ch; Cenci, R; Charles, M; Charpentier, Ph; Chen, P; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Couturier, B; Cowan, G A; Craik, D C; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; Davis, A; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Del Buono, L; Déléage, N; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Dijkstra, H; Dogaru, M; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Durante, P; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Falabella, A; Färber, C; Fardell, G; Farinelli, C; Farry, S; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Giubega, L; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gorbounov, P; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Griffith, P; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hamilton, B; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Hartmann, T; He, J; Head, T; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicheur, A; Hicks, E; Hill, D; Hoballah, M; Hombach, C; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jans, E; Jaton, P; Jawahery, A; Jing, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Kaballo, M; Kandybei, S; Kanso, W; Karacson, M; Karbach, T M; Kenyon, I R; Ketel, T; Keune, A; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leo, S; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lohn, S; Longstaff, I; Lopes, J H; Lopez-March, N; Lu, H; Lucchesi, D; Luisier, J; Luo, H; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Maratas, J; Marconi, U; Marino, P; Märki, R; Marks, J; Martellotti, G; Martens, A; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Maurice, E; Mazurov, A; Mc Skelly, B; McCarthy, J; McNab, A; McNulty, R; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M-N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mordà, A; Morello, M J; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neubert, S; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pal, B K; Palano, A; Palczewski, T; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pescatore, L; Pesen, E; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, A; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Roberts, D A; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rouvinet, J; Ruf, T; Ruffini, F; Ruiz, H; Ruiz Valls, P; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salustino Guimaraes, V; Sanmartin Sedes, B; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M-H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Sirendi, M; Skwarnicki, T; Smith, N A; Smith, E; Smith, J; Smith, M; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stevenson, S; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Sun, L; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urner, D; Ustyuzhanin, A; Uwer, U; Vagnoni, V; Valenti, G; Vallier, A; Van Dijk, M; Vazquez Gomez, R; Vazquez Regueiro, P; Vázquez Sierra, C; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, C; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiechczynski, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wimberley, J; Wishahi, J; Wislicki, W; Witek, M; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, Z; Yang, Z; Young, R; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2013-09-06

    The ratio of the Λb(0) baryon lifetime to that of the B(0) meson is measured using 1.0  fb(-1) of integrated luminosity in 7 TeV center-of-mass energy pp collisions at the LHC. The Λb(0) baryon is observed for the first time in the decay mode Λb(0)→J/ψpK-, while the B(0) meson decay used is the well known B(0)→J/ψπ+ K- mode, where the π+ K- mass is consistent with that of the K(*0)(892) meson. The ratio of lifetimes is measured to be 0.976±0.012±0.006, in agreement with theoretical expectations based on the heavy quark expansion. Using previous determinations of the B(0) meson lifetime, the Λb(0) lifetime is found to be 1.482±0.018±0.012  ps. In both cases, the first uncertainty is statistical and the second systematic.

  13. Size effect on strength and lifetime probability distributions of ...

    Indian Academy of Sciences (India)

    The safety factors required to ensure it are still determined empirically, even though they represent much larger and much more uncertain corrections to ... The theory is shown to match the experimentally observed systematic deviations of strength and lifetime histograms of industrial ceramics from the Weibull distribution.

  14. Predicting Customer Lifetime Value in Multi-Service Industries

    NARCIS (Netherlands)

    A.C.D. Donkers (Bas); P.C. Verhoef (Peter); M.G. de Jong (Martijn)

    2003-01-01

    textabstractCustomer lifetime value (CLV) is a key-metric within CRM. Although, a large number of marketing scientists and practitioners argue in favor of this metric, there are only a few studies that consider the predictive modeling of CLV. In this study we focus on the prediction of CLV in

  15. Profiling lifetime episodes of upper gastrointestinal bleeding among ...

    African Journals Online (AJOL)

    Profiling lifetime episodes of upper gastrointestinal bleeding among patients from rural Sub-Saharan Africa where schistosoma mansoni is endemic. ... female sex, history of blood transfusion, abdominal collaterals, esophageal varices, pattern x periportal fibrosis, anemia, and thrombocytopenia) significantly associated ...

  16. 2012 Next Generation Experiments to Measure the Neutron Lifetime Workshop

    CERN Document Server

    2014-01-01

    There is a great interest in improving the limits on neutron lifetime to the level of a precision of 0.1 s. The neutron lifetime is both an important fundamental quantity as well as a parameter influencing important processes such as nucleosynthesis (Helium production in the early universe) and the rate of energy production in the Sun. Aiming to create a roadmap of R&D for a next generation neutron lifetime experiment that can be endorsed by the North American neutron community, the focus of the workshop was on experiments using traps that utilize ultracold neutrons and confinement by a combination of magnetic and/or gravitational interaction in order to avoid systematic uncertainties introduced by neutron interactions with material walls. The papers in this volume summarize the limitations of present experiments, the discussion of new experiments in planning stage, and the discussion of systematic effects that must be addressed to achieve a lifetime measurement at an accuracy of 0.1 second.

  17. Size effect on strength and lifetime probability distributions of ...

    Indian Academy of Sciences (India)

    Size effect on strength and lifetime probability distributions of quasibrittle structures. #. ZDEN ˇEK P BAŽANT1,∗ and JIA-LIANG LE2. 1Department of Civil and Environmental Engineering, Northwestern University,. 2145 Sheridan Road, CEE/A135, Evanston, Illinois 60208, USA. 2Department of Civil Engineering, University ...

  18. Enhancing SOEC system lifetime by controlling inlet gas composition

    DEFF Research Database (Denmark)

    2015-01-01

    In a method for enhancing the lifetime of a solid oxide electrolysis cell system by counteracting nitridation of the threads of the in-line electrical heaters of the system, the start-up, shut-down and trip operations are done in a humidified nitrogen atmosphere on the fuel side to achieve a dew...

  19. Silica nanodisks as platforms for fluorescence lifetime-based ...

    Indian Academy of Sciences (India)

    Department of Chemistry, Indian Institute of Technology Bombay, Powai, Mumbai 400 076, India e-mail: anindya@chem.iitb.ac.in. Abstract. Core–shell conjugates of silica nanodisks and ..... the pre-exponential factors are treated as local parame- ters. It is observed that the longer global lifetime (τ1) increases in a sigmoidal ...

  20. Lifetime psychiatric comorbidity in hospitalized alcoholics: subject and familial correlates.

    Science.gov (United States)

    Hasin, D S; Grant, B F; Endicott, J

    1988-08-01

    We classified 123 alcohol rehabilitation patients by their histories of lifetime psychiatric comorbidity, and examined the demographic, social, occupational, treatment, and familial variables characterizing the groups. Diagnostic assessments were made with the SADS-L/RDC. High lifetime prevalences of major depressive disorder and drug use disorder were found. Aspects of treatment history distinguished between patient groups with and without lifetime major depression, but not other personal or familial variables. Patients with lifetime drug use disorders were younger and experienced an earlier onset of alcohol problems and treatment. Those with numerous childhood antisocial symptoms were younger, more likely to be male and unmarried, and less educated, and they had presented earlier for treatment. Subjects with two or more adult antisocial symptoms which occurred when subjects were not drinking or using drugs had a significant increase in family history of antisocial personality disorder. However, adult antisocial behaviors which were not separated from the effects of alcohol or drug use were unrelated to a family history of antisocial personality disorder. Implications of these findings are discussed.

  1. Catalyst deterioration over the lifetime of small utility engines.

    Science.gov (United States)

    Doll, Nicholas J; Reisel, John R

    2007-10-01

    In this paper, the deterioration of catalysts in small, four-stroke, spark-ignition engines is described. The laboratory testing performed followed a proven test method that mimics the lifetime of a small air-cooled utility engine operating under normal field conditions. The engines used were single-cylinder, 6.5-hp, side-valve engines. These engines have a nominal 125-hr lifetime. The effectiveness of the catalysts was determined by testing exhaust emissions before and after the catalyst to determine the catalyst's efficiency. This was done several times during the lifetime of the engines to determine the deterioration in the performance of the catalysts at lowering pollutant emissions. Additional testing was performed on the catalysts to determine wear patterns, contamination, and recoverable activity. The results indicate that considerable catalyst deterioration is occurring over the lifetime of the engine. The results reveal that soot buildup, poisons, and active surface loss appear to be the contributing factors to the deterioration. These results were determined after analyzing the exhaust emissions data, scanning electron microscope results analysis, and the impact of regeneration attempts. An ANOVA statistical analysis was performed, and it was determined that the emissions are also impacted, to some degree, by time and the engine itself.

  2. Lifetime Impact Identification for Continuous Improvement of Wind Farm Performance

    DEFF Research Database (Denmark)

    Petersen, Kristian R.; Ruitenburg, Richard J.; Madsen, Erik Skov

    2015-01-01

    in the offshore wind industry. In order to identify where to focus CI efforts, we turn to the theory of Asset Life Cycle Management which shows that a shared multidisciplinary understanding of the complete lifetime of a windfarm is critical. Based on a case study at a leading offshore wind farm company...

  3. Extending lifetime of wireless sensor networks using multi-sensor ...

    Indian Academy of Sciences (India)

    SOUMITRA DAS

    dissemination;. • explores the topology, communication structure, com- putational resources, fusion levels and optimization of. MSDF system architectures; also. • MSDF can be applied to any field of application where there is a need for prolongation of network lifetime;. • the new concept of having a node doing the dual role.

  4. Beam lifetime measurement and analysis in Indus-2 electron ...

    Indian Academy of Sciences (India)

    In this paper, the beam lifetime measurement and its theoretical analysis are presented using measured vacuum pressure and applied radio frequency (RF) cavity voltage in Indus-2 electron storage ring at 2 GeV beam energy. Experimental studies of the effect of RF cavity voltage and bunched beam filling pattern on beam ...

  5. Suicidal ideation and lifetime attempts in substance and gambling disorders.

    Science.gov (United States)

    Manning, Victoria; Koh, Puay Kee; Yang, Yi; Ng, Andrew; Guo, Song; Kandasami, Gomathinayagam; Wong, Kim Eng

    2015-02-28

    Suicidality is more commonly reported among individuals with addictions relative to the general population, though data from Asian countries remain scarce. The medical records of 2187 Singaporean patients with drug (n=879), alcohol (n=754) or gambling (n=554) disorders entering an outpatient treatment service were examined to explore differences in suicidal ideation and lifetime attempts between substance and gambling addictions. The relationship between suicidality, co-morbidity and addiction severity were also examined. 25.0% reported thoughts of suicide in the past month, 11.8% had a suicide plan and 12.2% reported lifetime attempts. Rates of suicidal ideation (thoughts, and plan) but not lifetime attempts were significantly higher among gambling than substance use patients. Co-morbid (DSM-IV axis-1) disorders were found among 32.5%, 38% and 40% of those reporting thoughts, plan and lifetime attempts respectively. Addiction severity was higher and quality of life lower among those reporting suicidal behaviors. Logistic regression revealed co-morbidity, debt, gender (being female) and being a gambling patient as significant predictors of suicidal behaviors. The findings highlight the importance of screening for suicidality, even in the absence of co-morbidity, particularly among gambling disorder patients with debts. Suicide risk should be assessed periodically and referral to suicidal prevention interventions routinely offered to this vulnerable population. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Carbocation lifetimes and entropy of water addition to carbocations ...

    Indian Academy of Sciences (India)

    Unknown

    effect of temperature on ksolv and ks the activation parameters are determined and discussed. Keywords. Nucleophilic solvation; carbocation lifetimes; entropy of water addition; α-azidobenzyl carbocations. 1. ... involves rearrangement with loss of molecular nitrogen from the putative imino- diazonium ions stabilized by an ...

  7. Network lifetime-aware data collection in Underwater Sensor ...

    Indian Academy of Sciences (India)

    Jalaja Janardanan Kartha

    2017-09-07

    Sep 7, 2017 ... We model the problem as a constrained optimization prob- lem, considering the peculiarities of the underwater environ- ment, resource limitations and application requirements. In particular, we formulate an optimization problem that maxi- mizes the lifetime of the UWSN, subject to node energy con- straints ...

  8. Fine-structure energy levels, oscillator strengths and lifetimes of ...

    Indian Academy of Sciences (India)

    We have done relativistic calculations for the evaluation of energy levels, oscillator strengths, transition probabilities and lifetimes for Cr VIII ion. Use has been made of configuration interaction technique by including Briet–Pauli approximation. The energies of various levels from the ground state to excited levels of 3s3p6, ...

  9. Studying membrane properties using Fluorescence Lifetime Imaging Microscopy (FLIM)

    NARCIS (Netherlands)

    Stöckl, M.T.; Bizzarri, R.; Subramaniam, Vinod; Mely, Y.; Duportail, G.

    2012-01-01

    Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool to investigate the structure and composition of biological membranes. A wide variety of fluorescent probes suitable for FLIM experiments have been described. These compounds differ strongly in the details of their incorporation into

  10. Lifetime Prediction of IGBT Modules based on Linear Damage Accumulation

    DEFF Research Database (Denmark)

    Choi, Uimin; Blaabjerg, Frede; Ma, Ke

    2017-01-01

    In this paper, the lifetime prediction of power device modules based on the linear damage accumulation in conjunction with real mission profile assessment is studied. Four tests are performed under two superimposed power cycling conditions using an advanced power cycling test setup with 600 V, 30...

  11. Precision measurement of the $\\Lambda_b^0$ baryon lifetime

    CERN Document Server

    INSPIRE-00258707; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves Jr, A A; Amato, S; Amerio, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Andrews, J E; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Baalouch, M; Bachmann, S; Back, J J; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bauer, Th; Bay, A; Beddow, J; Bedeschi, F; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M -O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Burducea, I; Bursche, A; Busetto, G; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Castillo Garcia, L; Cattaneo, M; Cauet, Ch; Cenci, R; Charles, M; Charpentier, Ph; Chen, P; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Couturier, B; Cowan, G A; Craik, D C; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; Davis, A; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Del Buono, L; Déléage, N; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Dijkstra, H; Dogaru, M; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Durante, P; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Falabella, A; Färber, C; Fardell, G; Farinelli, C; Farry, S; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Giubega, L; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gorbounov, P; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Griffith, P; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hamilton, B; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Hartmann, T; He, J; Head, T; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicheur, A; Hicks, E; Hill, D; Hoballah, M; Hombach, C; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jans, E; Jaton, P; Jawahery, A; Jing, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Kaballo, M; Kandybei, S; Kanso, W; Karacson, M; Karbach, T M; Kenyon, I R; Ketel, T; Keune, A; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J -P; Lefèvre, R; Leflat, A; Lefrançois, J; Leo, S; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lohn, S; Longstaff, I; Lopes, J H; Lopez-March, N; Lu, H; Lucchesi, D; Luisier, J; Luo, H; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Maratas, J; Marconi, U; Marino, P; Märki, R; Marks, J; Martellotti, G; Martens, A; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Maurice, E; Mazurov, A; Mc Skelly, B; McCarthy, J; McNab, A; McNulty, R; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M -N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Mordà, A; Morello, M J; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neubert, S; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pal, B K; Palano, A; Palczewski, T; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pescatore, L; Pesen, E; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, A; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Roberts, D A; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rouvinet, J; Ruf, T; Ruffini, F; Ruiz, H; Ruiz Valls, P; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salustino Guimaraes, V; Sanmartin Sedes, B; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Sirendi, M; Skwarnicki, T; Smith, N A; Smith, E; Smith, J; Smith, M; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stevenson, S; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Sun, L; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urner, D; Ustyuzhanin, A; Uwer, U; Vagnoni, V; Valenti, G; Vallier, A; Van Dijk, M; Vazquez Gomez, R; Vazquez Regueiro, P; Vázquez Sierra, C; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, C; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiechczynski, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wimberley, J; Wishahi, J; Wislicki, W; Witek, M; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, Z; Yang, Z; Young, R; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2013-01-01

    The ratio of the $\\Lambda_b^0$ baryon lifetime to that of the $\\overline{B}^0$ meson is measured using 1.0 fb$^{-1}$ of integrated luminosity in 7 TeV center-of-mass energy $pp$ collisions at the LHC. The $\\Lambda_b^0$ baryon is observed for the first time in the decay mode $\\Lambda_b^0 \\to J/\\psi p K^-$, while the $\\overline{B}^0$ meson decay used is the well known $\\overline{B}^0 \\to J/\\psi \\pi^+ K^-$ mode, where the $\\pi^+K^-$ mass is consistent with that of the $\\bar{K}^{*0}(892)$ meson. The ratio of lifetimes is measured to be $0.976\\pm0.012\\pm0.006$, in agreement with theoretical expectations based on the heavy quark expansion. Using previous determinations of the $\\overline{B}^0$ meson lifetime, the $\\Lambda_b^0$ lifetime is found to be $1.482 \\pm 0.018 \\pm 0.012$ ps. In both cases the first uncertainty is statistical and the second systematic.

  12. Effect of material environment on a class of nuclear lifetimes

    International Nuclear Information System (INIS)

    Perlow, G.J.

    1988-01-01

    The connection between internal conversion of a nuclear transition and EXAFS is pointed out. A prediction is made of sizable variations of lifetimes of nuclear states depending on the surrounding material environment, provided that the transition energy is just above threshold and the internal conversion coefficient is appreciable. 12 refs., 2 figs

  13. Incorporating Customer Lifetime Value into Marketing Simulation Games

    Science.gov (United States)

    Cannon, Hugh M.; Cannon, James N.; Schwaiger, Manfred

    2010-01-01

    Notwithstanding the emerging prominence of customer lifetime value (CLV) and customer equity (CE) in the marketing literature during the past decade, virtually nothing has been done to address these concepts in the literature on simulation and gaming. This article addresses the failing, discussing the nature of CLV and CE and demonstrating how…

  14. Silica nanodisks as platforms for fluorescence lifetime-based ...

    Indian Academy of Sciences (India)

    These dyes exhibit pH-dependent fluorescence properties. The nanoconjugates are found to sense the pH of the medium, through systematic variation of the fluorescence intensity ratios of the reporter dye at the surface and the reference dye at the core. Moreover, the fluorescence lifetimes and corresponding amplitudes of ...

  15. MEASUREMENT OF MINORITY-ARRIER LIFETIME IN SILICON ...

    African Journals Online (AJOL)

    Dr Obe

    1982-09-01

    Sep 1, 1982 ... In thermal equilibrium, the voltage drop along the section of the specimen to be illumated is Vo for a given constant current. When illumination starts, the voltage decreases, since additional carriers are being provided to support the current. The excess carrier lifetime can be determined from observations.

  16. Endogenous fertility and development traps with endogenous lifetime

    OpenAIRE

    Fanti, Luciano; Gori, Luca

    2010-01-01

    We extend the literature on endogenous lifetime and economic growth by Chakraborty (2004) and Bunzel and Qiao (2005) to endogenous fertility. We show that development traps due to underinvestments in health cannot appear when fertility is an economic decision variable and the costs of children are represented by a constant fraction of the parents' income used for their upbringing.

  17. Using Sport Education to Teach the Lifetime Sport of Golf

    Science.gov (United States)

    Scarboro, Shot; Pritchard, Tony

    2015-01-01

    Golf is a lifetime sport activity that can be taught in physical education classes. How one teaches golf in physical education could influence whether students will want to continue to participate outside of physical education. The sport education model (SEM) is an instructional model that promotes student learning in all three domains by ensuring…

  18. Mathematical Model of Lifetime Duration at Insulation of Electrical Machines

    Directory of Open Access Journals (Sweden)

    Mihaela Răduca

    2009-10-01

    Full Text Available Abstract. This paper present a mathematical model of lifetime duration at hydro generator stator winding insulation when at hydro generator can be appear the damage regimes. The estimation to make by take of the programming and non-programming revisions, through the introduction and correlation of the new defined notions.

  19. 50 CFR 600.760 - Fishery Negotiation Panel lifetime.

    Science.gov (United States)

    2010-10-01

    ... § 600.760 Fishery Negotiation Panel lifetime. (a) An FNP shall terminate upon either: (1) Submission of... FNP to the Council or NMFS that no consensus can be reached. (b) In no event shall an FNP exist for... the FNP to the Council or NMFS, and written authorization from the Council or NMFS (whichever is...

  20. Integrated tool for NPP lifetime management in Spain

    International Nuclear Information System (INIS)

    Francia, L.; Lopez de Santa Maria, J.; Cardoso, A.

    2001-01-01

    The project for the Integrated Nuclear Power Plant Lifetime Management System SIGEVI (Sistema Integrado de GEstion de VIda de Centrales Nucleares) was initiated in April 1998 and finalized in December 2000, the main objective of the project being to develop a computer application facilitating the assessment of the condition and lifetime of nuclear power plant components. This constituted the second phase of a further-reaching project on NPP Lifetime Management. During the first phase of this project, carried out between 1992 and 1995, the methodology and strategy for the lifetime management of the Spanish NPP's were developed. Among others, degradation phenomena were assessed and the most adequate methods for their monitoring were defined. The SIGEVI Project has been performed under the management of UNESA (Spanish Electricity Association) and with the collaboration of different engineering firms and research institutes (Tecnatom, Empresarios Agrupados, Ufisa, Initec and IIT), with Vandellos II as the pilot plant. The rest of the Spanish NPP's have also actively participated through the Project Steering Committee. The following sections describe the scope, the structure and the main functionalities of the system SIGEVI. (authors)

  1. Integrated tool for NPP lifetime management in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Francia, L. [UNESA, Madrid (Spain); Lopez de Santa Maria, J. [ASCO-Vandellos 2 NPPs l' Hospitalet de l' Infant, Tarragona (Spain); Cardoso, A. [Tecnatom SA, Madrid (Spain)

    2001-07-01

    The project for the Integrated Nuclear Power Plant Lifetime Management System SIGEVI (Sistema Integrado de GEstion de VIda de Centrales Nucleares) was initiated in April 1998 and finalized in December 2000, the main objective of the project being to develop a computer application facilitating the assessment of the condition and lifetime of nuclear power plant components. This constituted the second phase of a further-reaching project on NPP Lifetime Management. During the first phase of this project, carried out between 1992 and 1995, the methodology and strategy for the lifetime management of the Spanish NPP's were developed. Among others, degradation phenomena were assessed and the most adequate methods for their monitoring were defined. The SIGEVI Project has been performed under the management of UNESA (Spanish Electricity Association) and with the collaboration of different engineering firms and research institutes (Tecnatom, Empresarios Agrupados, Ufisa, Initec and IIT), with Vandellos II as the pilot plant. The rest of the Spanish NPP's have also actively participated through the Project Steering Committee. The following sections describe the scope, the structure and the main functionalities of the system SIGEVI. (authors)

  2. Development of an NPP residual lifetime evaluation system

    International Nuclear Information System (INIS)

    Regano, M.; Ibanez, M.; Hevia, F.

    1993-01-01

    Various reasons have given rise to the need for residual life management of Spain's nuclear power plants which lead to the a project for the development of a residual lifetime evaluation system managed by UNESA and supported by the owner groups. This project is described. 1 fig

  3. Carbocation lifetimes and entropy of water addition to carbocations ...

    Indian Academy of Sciences (India)

    Unknown

    Carbocation lifetimes and entropy of water addition to carbocations dependent on their stability. V JAGANNADHAM. Department of Chemistry, Osmania University, Hyderabad 500 007, India e-mail: jvandanapu@hotmail.com. MS received 11 January 2002. Abstract. Iminodiazonium ions (α-azidobenzyl carbocations) were ...

  4. On random age and remaining lifetime for populations of items

    DEFF Research Database (Denmark)

    Finkelstein, M.; Vaupel, J.

    2015-01-01

    develop the population studies approach to the problem and generalize the setting in terms of stationary and stable populations of items. We obtain new stochastic comparisons for the corresponding population ages and remaining lifetimes that can be useful in applications. Copyright (c) 2014 John Wiley...

  5. Lifetime prevalence rates of sleep paralysis: a systematic review.

    Science.gov (United States)

    Sharpless, Brian A; Barber, Jacques P

    2011-10-01

    To determine lifetime prevalence rates of sleep paralysis. Keyword term searches using "sleep paralysis", "isolated sleep paralysis", or "parasomnia not otherwise specified" were conducted using MEDLINE (1950-present) and PsychINFO (1872-present). English and Spanish language abstracts were reviewed, as were reference lists of identified articles. Thirty five studies that reported lifetime sleep paralysis rates and described both the assessment procedures and sample utilized were selected. Weighted percentages were calculated for each study and, when possible, for each reported subsample. Aggregating across studies (total N=36,533), 7.6% of the general population, 28.3% of students, and 31.9% of psychiatric patients experienced at least one episode of sleep paralysis. Of the psychiatric patients with panic disorder, 34.6% reported lifetime sleep paralysis. Results also suggested that minorities experience lifetime sleep paralysis at higher rates than Caucasians. Sleep paralysis is relatively common in the general population and more frequent in students and psychiatric patients. Given these prevalence rates, sleep paralysis should be assessed more regularly and uniformly in order to determine its impact on individual functioning and better articulate its relation to psychiatric and other medical conditions. Copyright © 2011. Published by Elsevier Ltd.

  6. Microstructures and their lifetimes in acetamide/electrolyte deep ...

    Indian Academy of Sciences (India)

    CH₃CONH₂) and lithium salts (LiX) have been performed at 303 K and 350 K to identify the solution-phase microstructures in these media and investigate the anion dependence of the size and lifetime distributions of these microstructures.

  7. Healthy and Creative Tap Dance: Teaching a Lifetime Physical Activity

    Science.gov (United States)

    Hernandez, Barbara L. Michiels; Ozmun, Michelle; Keeton, Gladys

    2013-01-01

    As a result of competitive dance television shows, interest in tap dance seems to have increased in the past few years. Tap dance is a challenging and fun lifetime physical activity that is appropriate for people of all ages. It is an excellent activity for K-12 physical education programs, higher education, parks and recreation facilities,…

  8. Mechanical stretch influence on lifetime of dielectric elastomer films

    NARCIS (Netherlands)

    Iannarelli, A.; Ghaffarian Niasar, M.; Bar-Cohen, Yoseph

    2017-01-01

    Film pre-stretching is a widely adopted solution to improve dielectric strength of the DEA systems. However, to date, long term reliability of this solution has not been investigated. In this work it is explored how the dielectric elastomer lifetime is affected by film pre-stretching. The dielectric

  9. Charmed-Particle Lifetimes from Neutrino Interactions Experiment #531

    Energy Technology Data Exchange (ETDEWEB)

    Reay, W. N. [Ohio State University

    1980-01-01

    Detection of charm in several Fermilab experiments, among them E-531, was discussed by L. Hand, L. Voyvodic, and the author in Fermilab Report in March 1979. Since that time, there have been significant new results from E-531 on charmed particles and their lifetimes and a discussion of these results is useful at this time.

  10. Interlaboratory comparison of positron and positronium lifetimes in polymers

    DEFF Research Database (Denmark)

    Wastlund, C.; Eldrup, Morten Mostgaard; Maurer, F.H.J.

    1998-01-01

    A comparison of the results of a series of positron annihilation lifetime measurements performed in 12 laboratories is presented. The measurements were conducted on three different polymer samples, all prepared in one laboratory under standard conditions. The objective of the work was to gain...

  11. [Spontaneous renal artery dissection: a case report].

    Science.gov (United States)

    Maehana, Takeshi; Nishida, Sachiyo; Shindo, Tetsuya; Miyamoto, Shintaro; Muranaka, Takashi; Suzuki, Kazuhiro; Yanase, Masahiro

    2008-01-01

    A 65-year-old female was admitted to our hospital complaining of left upper abdominal pain. Although the symptom improved with observation, serum creatinine rose to 2.0 mg/dl. Slight atrophy of the left kidney was seen on abdominal plain computed tomography. In order to examine the possibility of renal infarction from thrombosis with angiography, we consulted the department of cardiovascular medicine. Even though we did not detect thrombosis with left renal angiography or intravascular ultrasound, there was a dissection finding localized at the left renal artery. Based on this finding, we made a diagnosis of spontaneous renal artery dissection and performed stent placement. Spontaneous renal artery dissection is extremely rare and the frequency of occurrence is reported to be less than 0.05%. Recently, however the frequency of detection has risen with the development of clinical imaging. We must keep in mind that the condition has the possibility of leading to renal blood circulation disorders.

  12. Thermal influences on spontaneous rock dome exfoliation

    Science.gov (United States)

    Collins, Brian D.; Stock, Greg M.; Eppes, Martha C.; Lewis, Scott W.; Corbett, Skye C.; Smith, Joel B.

    2018-01-01

    Rock domes, with their onion-skin layers of exfoliation sheets, are among the most captivating landforms on Earth. Long recognized as integral in shaping domes, the exact mechanism(s) by which exfoliation occurs remains enigmatic, mainly due to the lack of direct observations of natural events. In August 2014, during the hottest days of summer, a granitic dome in California, USA, spontaneously exfoliated; witnesses observed extensive cracking, including a ~8000 kg sheet popping into the air. Subsequent exfoliation episodes during the following two summers were recorded by instrumentation that captured—for the first time—exfoliation deformation and stress conditions. Here we show that thermal cycling and cumulative dome surface heating can induce subcritical cracking that culminates in seemingly spontaneous exfoliation. Our results indicate that thermal stresses—largely discounted in dome formation literature—can play a key role in triggering exfoliation and therefore may be an important control for shaping domes worldwide.

  13. Spontaneous abortion and physical strain around implantation

    DEFF Research Database (Denmark)

    Hjøllund, Niels Henrik Ingvar; Jensen, T.K.; Bonde, J.P.

    2000-01-01

    Existing studies of physical strain and spontaneous abortion are mainly retrospective or based only on pregnancies that have survived the first trimester. Furthermore, almost all studies have relied on averaged measures of physical strain, which tend to blur an effect if peak values during short...... time periods are the relevant measure. We followed a cohort of first pregnancy planners from termination of birth control until pregnancy for a maximum of six menstrual cycles. The analyses include 181 pregnancies, of which 32 were subclinical pregnancies detected by hCG analysis only. During early...... pregnancy the women recorded physical strain prospectively in a structured diary. Physical strain around the time of implantation was associated with later spontaneous abortion. The adjusted risk ratio for women who reported physical strain higher than average at day 6 to 9 after the estimated date...

  14. Spontaneous Enterocutaneous Fistula Resulting from Richter's Hernia.

    Science.gov (United States)

    Hajong, Ranendra; Khongwar, Donkupar; Komut, Ojing; Naku, Narang; Baru, Kappa

    2017-08-01

    Richter's hernia is due to the entrapment of a part of circumference of the bowel wall. As the bowel continuity is maintained, the patients usually do not have intestinal obstruction. Some patients with Richter's hernia may present with enterocutaneous fistula either spontaneous or due to surgical intervention mistaking the obstructed hernia to be inguinal abscess. This is more so in developing countries due to lack of awareness among the masses or due to the delay in seeking medical attention. Presenting here is a case of a 53-year-old male patient with enterocutaneous fistula which occurred spontaneously and sought medical attention only after about three years of repeated discharge of yellowish fluid from the left inguinal region. Magnetic resonance fistulogram confirmed the diagnosis of enterocutaneous fistula. Laparotomy with resection and primary anastomosis of the fistulous bowel was done. Patient recovered uneventfully without any complications or recurrence.

  15. Spontaneous Coronary Artery Dissection and Pregnancy.

    Science.gov (United States)

    Naderi, Sahar

    2017-09-01

    Spontaneous coronary artery dissection (SCAD) is a non-atherosclerotic, non-traumatic cause of coronary artery dissection. SCAD is the most common cause of myocardial infarction in pregnancy or the postpartum period and results in significant cardiovascular morbidity and mortality in the pregnant population. It is important to consider pregnancy-associated spontaneous coronary artery dissection (PASCAD) high on the differential for a pregnant woman who presents with symptoms consistent with acute coronary syndrome. Management of these patients requires a thoughtful, multidisciplinary approach, with consideration of conservative management if possible. Counseling regarding future pregnancies is also critical and requires compassionate care. Given our limited understanding of SCAD, including PASCAD, more data and research are needed to help guide diagnosis, management, and determination of prognosis.

  16. Spontaneous stress fractures of the femoral neck

    International Nuclear Information System (INIS)

    Dorne, H.L.; Lander, P.H.

    1985-01-01

    The diagnosis of spontaneous stress fractures of the femoral neck, a form of insufficiency stress fracture, can be missed easily. Patients present with unremitting hip pain without a history of significant trauma or unusual increase in daily activity. The initial radiographic features include osteoporosis, minor alterations of trabecular alignment, minimal extracortical or endosteal reaction, and lucent fracture lines. Initial scintigraphic examinations performed in three of four patients showed focal increased radionuclide uptake in two and no focal abnormality in one. Emphasis is placed on the paucity of early findings. Evaluation of patients with persistent hip pain requires a high degree of clinical suspicion and close follow-up; the sequelae of undetected spontaneous fractures are subcapital fracture with displacement, angular deformity, and a vascular necrosis of the femoral head

  17. Motivational Projections of Russian Spontaneous Speech

    Directory of Open Access Journals (Sweden)

    Galina M. Shipitsina

    2017-06-01

    Full Text Available The article deals with the semantic, pragmatic and structural features of words, phrases, dialogues motivation, in the contemporary Russian popular speech. These structural features are characterized by originality and unconventional use. Language material is the result of authors` direct observation of spontaneous verbal communication between people of different social and age groups. The words and remarks were analyzed in compliance with the communication system of national Russian language and cultural background of popular speech. Studies have discovered that in spoken discourse there are some other ways to increase the expression statement. It is important to note that spontaneous speech identifies lacunae in the nominative language and its vocabulary system. It is proved, prefixation is also effective and regular way of the same action presenting. The most typical forms, ways and means to update language resources as a result of the linguistic creativity of native speakers were identified.

  18. Spontaneous pneumomediastinum due to paralytic rabies

    Directory of Open Access Journals (Sweden)

    Wuping Wang

    2013-02-01

    Full Text Available Rabies is a fatal disease resulting from rabies virus infection, causing severe neurological symptoms and ultimately death by destroying the nervous system. In general, a patient tends to see a neurologist or an infectious diseases physician, with very common and typical discipline-related signs and symptoms, such as hydrophobia, aerophobia, and mental disorders. However, we reported a rabies patient who was first admitted to see a thoracic surgeon with spontaneous pneumomediastinum.

  19. Spontaneous pneumomediastinum due to paralytic rabies

    Directory of Open Access Journals (Sweden)

    Wuping Wang

    Full Text Available Rabies is a fatal disease resulting from rabies virus infection, causing severe neurological symptoms and ultimately death by destroying the nervous system. In general, a patient tends to see a neurologist or an infectious diseases physician, with very common and typical discipline-related signs and symptoms, such as hydrophobia, aerophobia, and mental disorders. However, we reported a rabies patient who was first admitted to see a thoracic surgeon with spontaneous pneumomediastinum.

  20. Self energy QED: Multipole spontaneous emission

    International Nuclear Information System (INIS)

    Salamin, Y.I.

    1990-08-01

    Within the context of Barut's self-field approach, we write the exact expression of the spontaneous atomic decay rate (Phys. Rev. A37, 2284 (1988)), in the long wavelength approximation, in terms of electric- and magnetic-like multipole contributions which are related to the matrix elements of the transition charge and current distributions of the relativistic electron. A number of features of these expressions are discussed and their generalization to interacting composite systems is also pointed out. (author). 8 refs

  1. Quantum mechanics with spontaneous localization and experiments

    International Nuclear Information System (INIS)

    Benatti, F.; Grassi, R.

    1994-05-01

    We examine from an experimental point of view the recently proposed models of spontaneous reduction. We compare their implications about decoherence with those of environmental effects. We discuss the treatment, within the considered models, of the so called quantum telegraph phenomenon and we show that, contrary to what has been recently stated, no problems are met. Finally, we review recent interesting work investigating the implications of dynamical reduction for the proton decay. (author). 16 refs, 4 figs, 3 tabs

  2. Spontaneous atlantoaxial subluxation associated with tonsillitis

    OpenAIRE

    Shunmugam, Meenalochani; Poonnoose, Santosh

    2015-01-01

    Atlantoaxial subluxation is a rare condition and requires a high index of suspicion to diagnose and treat in order to avoid long-term sequelae. Here, we present a case of late presentation of a nontraumatic rotatory subluxation of the atlantoaxial joint or atlantoaxial rotatory subluxation. A 17-year-old girl presented 3 months after the onset of nonspecific upper limb sensory symptoms which eventually settled spontaneously. Initial conservative management by the general practitioner had no e...

  3. Rapid global fitting of large fluorescence lifetime imaging microscopy datasets.

    Directory of Open Access Journals (Sweden)

    Sean C Warren

    Full Text Available Fluorescence lifetime imaging (FLIM is widely applied to obtain quantitative information from fluorescence signals, particularly using Förster Resonant Energy Transfer (FRET measurements to map, for example, protein-protein interactions. Extracting FRET efficiencies or population fractions typically entails fitting data to complex fluorescence decay models but such experiments are frequently photon constrained, particularly for live cell or in vivo imaging, and this leads to unacceptable errors when analysing data on a pixel-wise basis. Lifetimes and population fractions may, however, be more robustly extracted using global analysis to simultaneously fit the fluorescence decay data of all pixels in an image or dataset to a multi-exponential model under the assumption that the lifetime components are invariant across the image (dataset. This approach is often considered to be prohibitively slow and/or computationally expensive but we present here a computationally efficient global analysis algorithm for the analysis of time-correlated single photon counting (TCSPC or time-gated FLIM data based on variable projection. It makes efficient use of both computer processor and memory resources, requiring less than a minute to analyse time series and multiwell plate datasets with hundreds of FLIM images on standard personal computers. This lifetime analysis takes account of repetitive excitation, including fluorescence photons excited by earlier pulses contributing to the fit, and is able to accommodate time-varying backgrounds and instrument response functions. We demonstrate that this global approach allows us to readily fit time-resolved fluorescence data to complex models including a four-exponential model of a FRET system, for which the FRET efficiencies of the two species of a bi-exponential donor are linked, and polarisation-resolved lifetime data, where a fluorescence intensity and bi-exponential anisotropy decay model is applied to the analysis

  4. A Measurement of the Bs Lifetime at CDF Run II

    Energy Technology Data Exchange (ETDEWEB)

    Farrington, Sinead [Boston Univ., MA (United States)

    2004-01-01

    This thesis describes a measurement of the proper lifetime of the B$0\\atop{s}$ mesons produced in proton-antiproton collisions at a center of mass energy of 1.96 TeV, collected by the CDF experiment at Fermilab. The B$0\\atop{s}$ meson lifetime is measured in its semileptonic decay mode, B$0\\atop{s}$ → ℓ+vD$-\\atop{s}$. The D$-\\atop{s}$ meson candidates are reconstructed in the decay mode D$-\\atop{s}$ → Φπ, with Φ → K+K-, in a trigger sample which requires a muon or an electron and another track which has a large impact parameters. The large impact parameter track is required by the silicon vertex trigger which is an innovative triggering device which has not previously been used in lifetime measurements. A total of 905 ± B$0\\atop{s}$ candidates are reconstructed in a sample which has an integrated luminosity of 140 pb-1 using data gathered between February 2002 and August 2003. The pseudo-proper lifetime distribution of these candidates is fitted with an unbinned maximum likelihood fit. This fit takes into account the missing momentum carried by the neutrino and the bias caused by requiring a track with large impact parameter by modeling these effects in simulations. The fit yields the result for the B$0\\atop{s}$ proper lifetime: cτ(B$0\\atop{s}$) = 419 ± 28$+16\\atop{-13}$ μm and τ(B$0\\atop{s}$) = 1.397 ± 0.093$+0.053\\atop{-0.043}$ ps where the first error is statistical and the second is systematic.

  5. Freezing shortens the lifetime of DNA molecules under tension.

    Science.gov (United States)

    Chung, Wei-Ju; Cui, Yujia; Chen, Chi-Shuo; Wei, Wesley H; Chang, Rong-Shing; Shu, Wun-Yi; Hsu, Ian C

    2017-12-01

    DNA samples are commonly frozen for storage. However, freezing can compromise the integrity of DNA molecules. Considering the wide applications of DNA molecules in nanotechnology, changes to DNA integrity at the molecular level may cause undesirable outcomes. However, the effects of freezing on DNA integrity have not been fully explored. To investigate the impact of freezing on DNA integrity, samples of frozen and non-frozen bacteriophage lambda DNA were studied using optical tweezers. Tension (5-35 pN) was applied to DNA molecules to mimic mechanical interactions between DNA and other biomolecules. The integrity of the DNA molecules was evaluated by measuring the time taken for single DNA molecules to break under tension. Mean lifetimes were determined by maximum likelihood estimates and variances were obtained through bootstrapping simulations. Under 5 pN of force, the mean lifetime of frozen samples is 44.3 min with 95% confidence interval (CI) between 36.7 min and 53.6 min while the mean lifetime of non-frozen samples is 133.2 min (95% CI: 97.8-190.1 min). Under 15 pN of force, the mean lifetimes are 10.8 min (95% CI: 7.6-12.6 min) and 78.5 min (95% CI: 58.1-108.9 min). The lifetimes of frozen DNA molecules are significantly reduced, implying that freezing compromises DNA integrity. Moreover, we found that the reduced DNA structural integrity cannot be restored using regular ligation process. These results indicate that freezing can alter the structural integrity of the DNA molecules.

  6. Societal and Family Lifetime Cost of Dementia: Implications for Policy.

    Science.gov (United States)

    Jutkowitz, Eric; Kane, Robert L; Gaugler, Joseph E; MacLehose, Richard F; Dowd, Bryan; Kuntz, Karen M

    2017-10-01

    To estimate the cost of dementia and the extra cost of caring for someone with dementia over the cost of caring for someone without dementia. We developed an evidence-based mathematical model to simulate disease progression for newly diagnosed individuals with dementia. Data-driven trajectories of cognition, function, and behavioral and psychological symptoms were used to model disease progression and predict costs. Using modeling, we evaluated lifetime and annual costs of individuals with dementia, compared costs of those with and without clinical features of dementia, and evaluated the effect of reducing functional decline or behavioral and psychological symptoms by 10% for 12 months (implemented when Mini-Mental State Examination score ≤21). Mathematical model. Representative simulated U.S. incident dementia cases. Value of informal care, out-of-pocket expenditures, Medicaid expenditures, and Medicare expenditures. From time of diagnosis (mean age 83), discounted total lifetime cost of care for a person with dementia was $321,780 (2015 dollars). Families incurred 70% of the total cost burden ($225,140), Medicaid accounted for 14% ($44,090), and Medicare accounted for 16% ($52,540). Costs for a person with dementia over a lifetime were $184,500 greater (86% incurred by families) than for someone without dementia. Total annual cost peaked at $89,000, and net cost peaked at $72,400. Reducing functional decline or behavioral and psychological symptoms by 10% resulted in $3,880 and $680 lower lifetime costs than natural disease progression. Dementia substantially increases lifetime costs of care. Long-lasting, effective interventions are needed to support families because they incur the most dementia cost. © 2017, Copyright the Authors Journal compilation © 2017, The American Geriatrics Society.

  7. Decreased spontaneous eye blink rates in chronic cannabis users: evidence for striatal cannabinoid-dopamine interactions.

    Directory of Open Access Journals (Sweden)

    Mikael A Kowal

    Full Text Available Chronic cannabis use has been shown to block long-term depression of GABA-glutamate synapses in the striatum, which is likely to reduce the extent to which endogenous cannabinoids modulate GABA- and glutamate-related neuronal activity. The current study aimed at investigating the effect of this process on striatal dopamine levels by studying the spontaneous eye blink rate (EBR, a clinical marker of dopamine level in the striatum. 25 adult regular cannabis users and 25 non-user controls matched for age, gender, race, and IQ were compared. Results show a significant reduction in EBR in chronic users as compared to non-users, suggesting an indirect detrimental effect of chronic cannabis use on striatal dopaminergic functioning. Additionally, EBR correlated negatively with years of cannabis exposure, monthly peak cannabis consumption, and lifetime cannabis consumption, pointing to a relationship between the degree of impairment of striatal dopaminergic transmission and cannabis consumption history.

  8. Spontaneous Regression of a Cervical Disk Herniation

    Directory of Open Access Journals (Sweden)

    Emre Delen

    2014-03-01

    Full Text Available A 54 years old female patient was admitted to our outpatient clinic with a two months history of muscle spasms of her neck and pain radiating to the left upper extremity. Magnetic resonance imaging had shown a large left-sided paracentral disk herniation at the C6-C7 disk space (Figure 1. Neurological examination showed no obvious neurological deficit. She received conservative treatment including bed rest, rehabilitation, and analgesic drugs. After 13 months, requested by the patient, a second magnetic resonance imaging study showed resolution of the disc herniation.(Figure 2 Although the literature contains several reports about spontaneous regression of herniated lumbar disc without surgical intervention, that of phenomenon reported for herniated cervical level is rare, and such reports are few[1]. In conclusion, herniated intervertebral disc have the potential to spontaneously regress independently from the spine level. With further studies, determining the predictive signs for prognostic evaluation for spontaneous regression which would yield to conservative treatment would be beneficial.

  9. Spontaneously emerging cortical representations of visual attributes

    Science.gov (United States)

    Kenet, Tal; Bibitchkov, Dmitri; Tsodyks, Misha; Grinvald, Amiram; Arieli, Amos

    2003-10-01

    Spontaneous cortical activity-ongoing activity in the absence of intentional sensory input-has been studied extensively, using methods ranging from EEG (electroencephalography), through voltage sensitive dye imaging, down to recordings from single neurons. Ongoing cortical activity has been shown to play a critical role in development, and must also be essential for processing sensory perception, because it modulates stimulus-evoked activity, and is correlated with behaviour. Yet its role in the processing of external information and its relationship to internal representations of sensory attributes remains unknown. Using voltage sensitive dye imaging, we previously established a close link between ongoing activity in the visual cortex of anaesthetized cats and the spontaneous firing of a single neuron. Here we report that such activity encompasses a set of dynamically switching cortical states, many of which correspond closely to orientation maps. When such an orientation state emerged spontaneously, it spanned several hypercolumns and was often followed by a state corresponding to a proximal orientation. We suggest that dynamically switching cortical states could represent the brain's internal context, and therefore reflect or influence memory, perception and behaviour.

  10. Spontaneous prediction error generation in schizophrenia.

    Directory of Open Access Journals (Sweden)

    Yuichi Yamashita

    Full Text Available Goal-directed human behavior is enabled by hierarchically-organized neural systems that process executive commands associated with higher brain areas in response to sensory and motor signals from lower brain areas. Psychiatric diseases and psychotic conditions are postulated to involve disturbances in these hierarchical network interactions, but the mechanism for how aberrant disease signals are generated in networks, and a systems-level framework linking disease signals to specific psychiatric symptoms remains undetermined. In this study, we show that neural networks containing schizophrenia-like deficits can spontaneously generate uncompensated error signals with properties that explain psychiatric disease symptoms, including fictive perception, altered sense of self, and unpredictable behavior. To distinguish dysfunction at the behavioral versus network level, we monitored the interactive behavior of a humanoid robot driven by the network. Mild perturbations in network connectivity resulted in the spontaneous appearance of uncompensated prediction errors and altered interactions within the network without external changes in behavior, correlating to the fictive sensations and agency experienced by episodic disease patients. In contrast, more severe deficits resulted in unstable network dynamics resulting in overt changes in behavior similar to those observed in chronic disease patients. These findings demonstrate that prediction error disequilibrium may represent an intrinsic property of schizophrenic brain networks reporting the severity and variability of disease symptoms. Moreover, these results support a systems-level model for psychiatric disease that features the spontaneous generation of maladaptive signals in hierarchical neural networks.

  11. Spontaneous Large Serous Retinal Pigment Epithelial Tear

    Directory of Open Access Journals (Sweden)

    Voraporn Chaikitmongkol

    2012-10-01

    Full Text Available Purpose: To report cases of spontaneous retinal pigment epithelial (RPE tear complicating serous pigment epithelial detachment (PED. Methods: The records of 3 Asian patients with spontaneous giant RPE tear were reviewed retrospectively by including clinical presentation, angiography, optical coherence tomography, fundus autofluorescence imaging, and visual outcome. Results: Three patients (4 eyes were included in this study, with a mean age of 48.3 (42–56 years, and a mean follow-up period of 7.75 (4–18 months. Fundus examination in all patients showed giant RPE tear associated with bullous PED. Two cases had a history of prior corticosteroid use, and 1 had no history of medication use. All 3 patients developed spontaneous resolution of subretinal fluid with no treatment. However, in patients who used corticosteroids, initial progression of the tear and subretinal fluid were observed despite ceasing medication. On subsequent follow-up, an incomplete RPE regeneration was demonstrated by fundus autofluorescence imaging, and choroidal neovascularization developed in 1 patient. Conclusion: Large PED with RPE tear is a rare manifestation. When the fovea is spared, visual prognosis is favorable. No specific treatment is required, but careful choroidal neovascularization monitoring should be performed.

  12. Spontaneous fission of the heaviest elements

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, D.C.

    1989-04-01

    Although spontaneous fission was discovered in /sup 238/U in 1940, detailed studies of the process were first made possible in the 1960's with the availability of milligram quantities of /sup 252/Cf. The advent of solid-state detectors made it possible to perform measurements of coincident fission fragments from even very short-lived spontaneous fission activities or those available in only very small quantities. Until 1971 it was believed that the main features of the mass and kinetic-energy distributions were essentially the same as those for thermal neutron-induced fission and that all low-energy fission proceeded via asymmetric mass division with total kinetic energies which could be derived by linear extrapolation from those of lighter elements. In 1971, measurements of /sup 257/Fm showed an increase in symmetric mass division with anomalously high TKE's. Subsequent experiments showed that in /sup 258/Fm and /sup 259/Fm, the most probable mass split was symmetric with very high total kinetic energy. Measurements for the heavier elements have shown symmetric mass distributions with both high and low total kinetic energies. Recent results for spontaneous fission properties of the heaviest elements are reviewed and compared with theory. 31 refs., 8 figs., 1 tab.

  13. Identification of Common Genetic Variants Influencing Spontaneous Dizygotic Twinning and Female Fertility

    Science.gov (United States)

    Mbarek, Hamdi; Steinberg, Stacy; Nyholt, Dale R.; Gordon, Scott D.; Miller, Michael B.; McRae, Allan F.; Hottenga, Jouke Jan; Day, Felix R.; Willemsen, Gonneke; de Geus, Eco J.; Davies, Gareth E.; Martin, Hilary C.; Penninx, Brenda W.; Jansen, Rick; McAloney, Kerrie; Vink, Jacqueline M.; Kaprio, Jaakko; Plomin, Robert; Spector, Tim D.; Magnusson, Patrik K.; Reversade, Bruno; Harris, R. Alan; Aagaard, Kjersti; Kristjansson, Ragnar P.; Olafsson, Isleifur; Eyjolfsson, Gudmundur Ingi; Sigurdardottir, Olof; Iacono, William G.; Lambalk, Cornelis B.; Montgomery, Grant W.; McGue, Matt; Ong, Ken K.; Perry, John R.B.; Martin, Nicholas G.; Stefánsson, Hreinn; Stefánsson, Kari; Boomsma, Dorret I.

    2016-01-01

    Spontaneous dizygotic (DZ) twinning occurs in 1%–4% of women, with familial clustering and unknown physiological pathways and genetic origin. DZ twinning might index increased fertility and has distinct health implications for mother and child. We performed a GWAS in 1,980 mothers of spontaneous DZ twins and 12,953 control subjects. Findings were replicated in a large Icelandic cohort and tested for association across a broad range of fertility traits in women. Two SNPs were identified (rs11031006 near FSHB, p = 1.54 × 10−9, and rs17293443 in SMAD3, p = 1.57 × 10−8) and replicated (p = 3 × 10−3 and p = 1.44 × 10−4, respectively). Based on ∼90,000 births in Iceland, the risk of a mother delivering twins increased by 18% for each copy of allele rs11031006-G and 9% for rs17293443-C. A higher polygenic risk score (PRS) for DZ twinning, calculated based on the results of the DZ twinning GWAS, was significantly associated with DZ twinning in Iceland (p = 0.001). A higher PRS was also associated with having children (p = 0.01), greater lifetime parity (p = 0.03), and earlier age at first child (p = 0.02). Allele rs11031006-G was associated with higher serum FSH levels, earlier age at menarche, earlier age at first child, higher lifetime parity, lower PCOS risk, and earlier age at menopause. Conversely, rs17293443-C was associated with later age at last child. We identified robust genetic risk variants for DZ twinning: one near FSHB and a second within SMAD3, the product of which plays an important role in gonadal responsiveness to FSH. These loci contribute to crucial aspects of reproductive capacity and health. PMID:27132594

  14. Sex in a lifetime: Sexual behaviors in the United States by lifetime number of sex partners, 2006-2010.

    Science.gov (United States)

    Haderxhanaj, Laura T; Leichliter, Jami S; Aral, Sevgi O; Chesson, Harrell W

    2014-06-01

    Using data from the 2006-2010 National Survey of Family Growth, we found that lifetime number of vaginal sex partners is positively associated with the number of sex partners in the past 12 months and negatively associated with age at first vaginal intercourse among 15- to 44-year-old male and female respondents.

  15. Modulated electron-multiplied fluorescence lifetime imaging microscope : All-solid-state camera for fluorescence lifetime imaging

    NARCIS (Netherlands)

    Zhao, Q.; Schelen, B.; Schouten, R.

    2012-01-01

    We have built an all-solid-state camera that is directly modulated at the pixel level for frequency-domain fluorescence lifetime imaging microscopy (FLIM) measurements. This novel camera eliminates the need for an image intensifier through the use of an application-specific charge coupled device

  16. Spontaneous Coronary Artery Dissection Associated With Pregnancy.

    Science.gov (United States)

    Tweet, Marysia S; Hayes, Sharonne N; Codsi, Elisabeth; Gulati, Rajiv; Rose, Carl H; Best, Patricia J M

    2017-07-25

    Spontaneous coronary artery dissection (SCAD) is the most common cause of pregnancy-associated myocardial infarction and remains poorly characterized. This study sought to assess presentation, clinical factors, and outcomes of pregnancy-associated spontaneous coronary artery dissection (P-SCAD) compared with spontaneous coronary artery dissection not associated with pregnancy (NP-SCAD). A Mayo Clinic registry was established in 2010 to include comprehensive retrospective and prospective SCAD data. Records were reviewed to identify women who were pregnant or ≤12 weeks postpartum at time of SCAD. Complete records were available for 323 women; 54 women met criteria for P-SCAD (4 during pregnancy) and they were compared with 269 women with NP-SCAD. Most events occurred within the first month postpartum (35 of 50). Compared with NP-SCAD, P-SCAD patients more frequently presented with ST-segment elevation myocardial infarction (57% vs. 36%; p = 0.009), left main or multivessel SCAD (24% vs. 5%; p vs. 14%; p = 0.0027, respectively), and left ventricular function ≤35% (26% vs. 10%; p = 0.0071). Among women with imaging of other vascular territories, P-SCAD was less likely with a diagnosis of fibromuscular dysplasia and extracoronary vascular abnormalities (42% vs. 64%; p = 0.047; and 46% vs. 77%; p = 0.0032, respectively). Compared with U.S. birth data, women with P-SCAD were more often multiparous (p = 0.0167), had a history of infertility therapies (p = 0.0004), and had pre-eclampsia (p = 0.001). On long-term follow-up (median 2.3 years) recurrent SCAD occurred in 51 patients, with no difference in the Kaplan Meier 5-year recurrence rates (10% vs. 23%; p = 0.18). P-SCAD patients had more acute presentations and high-risk features than women with NP-SCAD did. The highest frequency of P-SCAD occurred during the first postpartum month and P-SCAD patients less often had extracoronary vascular abnormalities. Hormonal, hemodynamic variations, and yet

  17. Remaining lifetime modeling using State-of-Health estimation

    Science.gov (United States)

    Beganovic, Nejra; Söffker, Dirk

    2017-08-01

    Technical systems and system's components undergo gradual degradation over time. Continuous degradation occurred in system is reflected in decreased system's reliability and unavoidably lead to a system failure. Therefore, continuous evaluation of State-of-Health (SoH) is inevitable to provide at least predefined lifetime of the system defined by manufacturer, or even better, to extend the lifetime given by manufacturer. However, precondition for lifetime extension is accurate estimation of SoH as well as the estimation and prediction of Remaining Useful Lifetime (RUL). For this purpose, lifetime models describing the relation between system/component degradation and consumed lifetime have to be established. In this contribution modeling and selection of suitable lifetime models from database based on current SoH conditions are discussed. Main contribution of this paper is the development of new modeling strategies capable to describe complex relations between measurable system variables, related system degradation, and RUL. Two approaches with accompanying advantages and disadvantages are introduced and compared. Both approaches are capable to model stochastic aging processes of a system by simultaneous adaption of RUL models to current SoH. The first approach requires a priori knowledge about aging processes in the system and accurate estimation of SoH. An estimation of SoH here is conditioned by tracking actual accumulated damage into the system, so that particular model parameters are defined according to a priori known assumptions about system's aging. Prediction accuracy in this case is highly dependent on accurate estimation of SoH but includes high number of degrees of freedom. The second approach in this contribution does not require a priori knowledge about system's aging as particular model parameters are defined in accordance to multi-objective optimization procedure. Prediction accuracy of this model does not highly depend on estimated SoH. This model

  18. Prediction of lifetime for ceramic materials in the elastic and viscoelastic region by fracture mechanical methods

    International Nuclear Information System (INIS)

    Fett, T.

    1983-01-01

    The investigation is mainly concerned with the effect of subcritical crack growth of ceramic materials on lifetime in static bending test and lifetime predictions. In the theoretical part the formulas of lifetime and dynamic bending strength are discussed in detail. In case of creep behaviour a procedure is proposed to make predictions possible. The experiments on Al 2 O 3 and HPSN give a good agreement between predicted and measured lifetimes for linear elastic material behaviour. If creep behaviour dominates, the region of expected lifetimes and the qualitative shape of lifetime distribution can be predicted too. (orig.) [de

  19. DEFORMATION INFLUENCE ON A LIFETIME OF WELDING ELECTRODE TIPS

    Directory of Open Access Journals (Sweden)

    Ján Viňáš

    2009-02-01

    Full Text Available The contribution deals with the influence of welding electrode tips deformation on their lifetime. The influence of material properties, production technology and the intensity of welding electrodes load on their lifetime are presented. The electrode tips of the most used type of CuCr1Zr alloy of three basic standard shapes before and after the process of welding are evaluated. The process of welding is realized with low, middle and maximum welding parameters on programmable pneumatic spot welding machine VTS BPK 20. The influence of welding parameters on chosen material characteristics of welding tips is observed. Through the use of upsetting test, dependency of forming strength and deformation of material on used technology of welding tip production is observed.

  20. Lifetime management research trend of Kori-1 nuclear power plant

    International Nuclear Information System (INIS)

    Kim, J. S.; Jeong, I. S.; Hong, S. Y.

    1998-01-01

    KEPRI launched the Nuclear Power Plant Lifetime Management Study(II) for the management of the latter half life of Kori-1. Main goal of LCM-IV study is the detail evaluation of main equipment life and establishment of aging management based on LCM-IV result. The result of LCM-IV on the kori-1 confirmed the technical and economical feasibility of life extension beyond the design life. Owing to absence of The regulatory policy for the life extension in korea, LCM-IV will focus on the minimum study which is essential for the actual lifetime management for the old nuclear power plant. License renewal study is expected after the establishment of Regulatory policy about the life extension of nuclear power plant. LCM trend in korea and abroad, result of technical and economical feasibility study and summary of LCM-IV is described on this paper