WorldWideScience

Sample records for spme solid phase

  1. Use of solid phase microextraction (SPME) for profiling the volatile metabolites produced by Glomerella cingulata.

    Science.gov (United States)

    Miyazawa, Mitsuo; Kimura, Minako; Yabe, Yoshito; Tsukamoto, Daisuke; Sakamoto, Masaya; Horibe, Isao; Okuno, Yoshiharu

    2008-01-01

    The profile of volatile organic compounds (VOCs) released from Glomerella cingulata using solid phase microextraction (SPME) with different fibers, Polydimethylsiloxane (PDMS), Polydimethylsiloxane/Divinylbenzene (PDMS/DVB), Carboxen/Polydimethylsiloxane (CAR/PDMS) and Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), was investigated. C4-C6 aliphatic alcohols were the predominant fraction of VOCs isolated by CAR/PDMS fiber. Sesquiterpene hydrocarbons represented 20.3% of VOCs isolated by PDMS fiber. During the growth phase, Ochracin was produced in the large majority of VOCs. 3-Methylbutanol and phenylethyl alcohol were found in the log phase of it. Alcohols were found in cultures of higher age, while sesquiterpenes were found to be characteristic of initial growth stage of G. cingulata.

  2. Freeze-thaw method improves the detection of volatile compounds in insects using Headspace Solid-Phase Microextraction (HS-SPME)

    Science.gov (United States)

    Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography–mass spectrometry (GC-MS) is commonly used in analyzing insect volatiles. In order to improve the detection of volatiles in insects, a freeze-thaw method was applied to insect samples before the HS-SPME-GC-MS analysis. ...

  3. Recent Developments and Applications of Solid Phase Microextraction (SPME in Food and Environmental Analysis—A Review

    Directory of Open Access Journals (Sweden)

    Sybille Merkle

    2015-06-01

    Full Text Available Solid-phase microextraction (SPME is a simple, sensitive, rapid and solvent-free technique for the extraction of analytes from gaseous, liquid and solid samples and takes a leading position among microextraction methods. Application of SPME in sample preparation has been increasing continuously over the last decade. It is most often used as an automatized fiber injection system coupled to chromatographic separation modules for the extraction of volatile and semivolatile organic compounds and also allows for the trace analysis of compounds in complex matrices. Since SPME was first introduced in the early 1990s, several modifications have been made to adapt the procedure to specific application requirements. More robust fiber assemblies and coatings with higher extraction efficiencies, selectivity and stability have been commercialized. Automation and on-line coupling to analytical instruments have been achieved in many applications and new derivatization strategies as well as improved calibration procedures have been developed to overcome existing limitations regarding quantitation. Furthermore, devices using tubes, needles or tips for extraction instead of a fiber have been designed. In the field of food analysis, SPME has been most often applied to fruit/vegetables, fats/oils, wine, meat products, dairy and beverages whereas environmental applications focus on the analysis of air, water, soil and sediment samples.

  4. A Headspace Solid Phase Microextraction (HS-SPME method for the chromatographic determination of alkylpyrazines in cocoa samples

    Directory of Open Access Journals (Sweden)

    Pini Gláucia F.

    2004-01-01

    Full Text Available A Headspace Solid Phase Microextraction (HS-SPME procedure for isolation and determination of alkylpyrazines in cocoa liquor, using Gas Chromatography with Flame Ionization Detection (GC-FID for the separation and detection of the analytes, is presented here. The HS-SPME operational conditions were optimized using extractions of samples spiked with known amounts of alkylpyrazines typically found on cocoa products. The maximum extraction efficiency was obtained using SPME fibers coated with 65 µm Carbowax/divinylbenzene. Additionally, the best results were achieved with extraction temperature of 60 ºC, 15 min of sample/headspace equilibration time and 45 min extraction time. It was also observed that suspending the samples in saturated aqueous NaCl solution during extractions resulted in a significant increment on the peak areas. This procedure was found to be effective to determine the so-called pyrazinic ratios (quotient between peak areas of alkylpyrazines, which are useful as quality parameters for cocoa liquor.

  5. Quantitative Analysis of Bisphenol A Leached from Household Plastics by Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry (SPME-GC-MS)

    Science.gov (United States)

    Johnson, Bettie Obi; Burke, Fernanda M.; Harrison, Rebecca; Burdette, Samantha

    2012-01-01

    The measurement of trace levels of bisphenol A (BPA) leached out of household plastics using solid-phase microextraction (SPME) with gas chromatography-mass spectrometry (GC-MS) is reported here. BPA is an endocrine-disrupting compound used in the industrial manufacture of polycarbonate plastic bottles and epoxy resin can liners. This experiment…

  6. Comparison between solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HFLPME) for determination of extractables from post-consumer recycled PET into food simulants.

    Science.gov (United States)

    Oliveira, Éder Costa; Echegoyen, Yolanda; Cruz, Sandra Andrea; Nerin, Cristina

    2014-09-01

    Hollow fiber liquid phase microextraction (HFLPME) and solid phase microextraction (SPME) methods for pre-concentration of contaminants (toluene, benzophenone, tetracosane and chloroform) in food simulants were investigated. For HFLPME 1-heptanol, 2-octanone and dibutyl-ether were studied as extracting solvents. Analysis by gas chromatography coupled to mass spectrometry (GC-MS), flame ionization (GC-FID) and electron capture detectors (GC-ECD) were carried out. In addition, the methods were employed to evaluate the safety in use of a PET material after the recycling process (comprising washing, extrusion and solid state polymerization (SSP)) through extractability studies of the contaminants using 10% (v/v) ethanol in deionized water and 3% (w/v) acetic acid in deionized water as food simulants in different conditions: 10 days at 40°C and 2h at 70°C. The HFLPME preconcentration method provided increased sensitivity when compared to the SPME method and allowed to analyze concentration levels below 10 µg surrogate per kg food simulant. The results of the extractability studies showed considerable reductions after the extrusion and SSP processes and indicated the compliance with regulations for using recycled PET in contact with food. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Ultra trace analysis of PAHs by designing simple injection of large amounts of analytes through the sample reconcentration on SPME fiber after magnetic solid phase extraction.

    Science.gov (United States)

    Khodaee, Nader; Mehdinia, Ali; Esfandiarnejad, Reyhaneh; Jabbari, Ali

    2016-01-15

    A simple solventless injection method was introduced based on the using of a solid-phase microextraction (SPME) fiber for injection of large amounts of the analytes extracted by the magnetic solid phase extraction (MSPE) procedure. The resulted extract from MSPE procedure was loaded on a G-coated SPME fiber, and then the fiber was injected into the gas chromatography (GC) injection port. This method combines the advantages of exhaustive extraction property of MSPE and the solvent-less injection of SPME to improve the sensitivity of the analysis. In addition, the analytes were re-concentrated prior to inject into the gas chromatography (GC) inlet because of the organic solvent removing from the remaining extract of MSPE technique. Injection of the large amounts of analytes was made possible by using the introduced procedure. Fourteen polycyclic aromatic hydrocarbons (PAHs) with different volatility were used as model compounds to investigate the method performance for volatile and semi-volatile compounds. The introduced method resulted in the higher enhancement factors (5097-59376), lower detection limits (0.29-3.3pgmL(-1)), and higher sensitivity for the semi-volatile compounds compared with the conventional direct injection method. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Determination of organotin compounds by headspace solid-phase microextraction-gas chromatography-pulsed flame-photometric detection (HS-SPME-GC-PFPD)

    Energy Technology Data Exchange (ETDEWEB)

    Bravo, Manuel [Universite de Pau et des Pays de L' Adour, Laboratoire de Chimie Analytique, LCABIE, UMR CNRS 5034, Pau (France); Pontificia Universidad Catolica de Valparaiso, Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Valparaiso (Chile); Lespes, Gaetane; Gautier, Martine Potin [Pontificia Universidad Catolica de Valparaiso, Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Valparaiso (Chile); Gregori, Ida de; Pinochet, Hugo [Universite de Pau et des Pays de L' Adour, Laboratoire de Chimie Analytique, LCABIE, UMR CNRS 5034, Pau (France)

    2005-12-01

    A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 {mu}m PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L{sup -1} in water and close to ng (Sn) kg{sup -1} in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME-GC-PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices. (orig.)

  9. Determination of organotin compounds by headspace solid-phase microextraction-gas chromatography-pulsed flame-photometric detection (HS-SPME-GC-PFPD).

    Science.gov (United States)

    Bravo, Manuel; Lespes, Gaëtane; De Gregori, Ida; Pinochet, Hugo; Gautier, Martine Potin

    2005-12-01

    A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 mum PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L(-1) in water and close to ng (Sn) kg(-1) in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME-GC-PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices.

  10. Determination of different recreational drugs in sweat by headspace solid-phase microextraction gas chromatography mass spectrometry (HS-SPME GC/MS): Application to drugged drivers.

    Science.gov (United States)

    Gentili, Stefano; Mortali, Claudia; Mastrobattista, Luisa; Berretta, Paolo; Zaami, Simona

    2016-09-10

    A procedure based on headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) has been developed for the determination of most commonly used drugs of abuse in sweat of drivers stopped during roadside controls. DrugWipe 5A sweat screening device was used to collect sweat by a specific pad rubbed gently over forehead skin surface. The procedure involved an acid hydrolysis, a HS-SPME extraction for drugs of abuse but Δ(9)-tetrahydrocannabinol, which was directly extracted in alkaline medium HS-SPME conditions, a GC separation of analytes by a capillary column and MS detection by electron impact ionisation. The method was linear from the limit of quantification (LOQ) to 50ng drug per pad (r(2)≥0.99), with an intra- and inter-assay precision and accuracy always less than 15% and an analytical recovery between 95.1% and 102.8%, depending on the considered analyte. Using the validated method, sweat from 60 apparently intoxicated drivers were found positive to one or more drugs of abuse, showing sweat patches testing as a viable economic and simple alternative to conventional (blood and/or urine) and non conventional (oral fluid) testing of drugs of abuse in drugged drivers. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Headspace solid-phase microextraction (HS-SPME) combined with GC-MS as a process analytical technology (PAT) tool for monitoring the cultivation of C. tetani.

    Science.gov (United States)

    Ghader, Masoud; Shokoufi, Nader; Es-Haghi, Ali; Kargosha, Kazem

    2018-02-06

    Vaccine production is a biological process in which variation in time and output is inevitable. Thus, the application of Process Analytical Technologies (PAT) will be important in this regard. Headspace solid - phase microextraction (HS-SPME) coupled with GC-MS can be used as a PAT for process monitoring. This method is suitable to chemical profiling of volatile organic compounds (VOCs) emitted from microorganisms. Tetanus is a lethal disease caused by Clostridium tetani (C. tetani) bacterium and vaccination is an ultimate way to prevent this disease. In this paper, SPME fiber was used for the investigation of VOCs emerging from C. tetani during cultivation. Different types of VOCs such as sulfur-containing compounds were identified and some of them were selected as biomarkers for bioreactor monitoring during vaccine production. In the second step, the portable dynamic air sampling (PDAS) device was used as an interface for sampling VOCs by SPME fibers. The sampling procedure was optimized by face-centered central composite design (FC-CCD). The optimized sampling time and inlet gas flow rates were 10 min and 2 m L s -1 , respectively. PDAS was mounted in exhausted gas line of bioreactor and 42 samples of VOCs were prepared by SPME fibers in 7 days during incubation. Simultaneously, pH and optical density (OD) were evaluated to cultivation process which showed good correlations with the identified VOCs (>80%). This method could be used for VOCs sampling from off-gas of a bioreactor to monitoring of the cultivation process. Copyright © 2018. Published by Elsevier B.V.

  12. Optimization of total vaporization solid-phase microextraction (TV-SPME) for the determination of lipid profiles of Phormia regina, a forensically important blow fly species.

    Science.gov (United States)

    Kranz, William; Carroll, Clinton; Dixon, Darren; Picard, Christine; Goodpaster, John

    2017-11-01

    A new method has been developed for the determination of fatty acids, sterols, and other lipids which naturally occur within pupae of the blow fly Phormia regina. The method relies upon liquid extraction in non-polar solvent, followed by derivatization using N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) w/ 1% trimethylchlorsilane (TMCS) carried out inside the sample vial. The analysis is facilitated by total vaporization solid-phase microextraction (TV-SPME), with gas chromatography-mass spectrometry (GC-MS) serving as the instrumentation for analysis. The TV-SPME delivery technique is approximately a factor of five more sensitive than traditional liquid injection, which may alleviate the need for rotary evaporation, reconstitution, collection of high performance liquid chromatography fractions, and many of the other pre-concentration steps that are commonplace in the current literature. Furthermore, the ability to derivatize the liquid extract in a single easy step while increasing sensitivity represents an improvement over current derivatization methods. The most common lipids identified in fly pupae were various saturated and unsaturated fatty acids ranging from lauric acid (12:0) to arachinoic acid (20:4), as well as cholesterol. The concentrations of myristic acid (14:0), palmitelaidic acid (16:2), and palmitoleic acid (16:1) were the most reliable indicators of the age of the pupae. Graphical abstract Blow fly pupae were extracted prior to emerging as adults. The extracts were analyzed via total vaporization solid-phase microextraction (TV-SPME), revealing a complex mixture of lipids that could be associated with the age of the insect. This information may assist in determining a post-mortum interval (PMI) in a death investigation.

  13. Solid phase microextraction (SPME) for extraction of volatile oxidation products from complex food systems – Pros and cons

    DEFF Research Database (Denmark)

    Jacobsen, Charlotte; Horn, Anna Frisenfeldt; Lu, Henna Fung Sieng

    efficiency obtained with the SPME method can be affected by different factors such as fiber type, stirring of sample versus not stirring, extraction temperature and time. These factors can easily be controlled and optimized to obtain the highest possible extraction efficiency. However, extraction efficiency...... can also be affected by uncontrollable factors such as batch to batch variation between fibers of the same type and presence of compounds in the sample matrix, which competes with the compounds of interest for adsorption to the SPME fiber. The latter factor is particularly a problem when SPME is used...... for analysis of lipid oxidation during storage of complex food matrices. Examples on how uncontrollable factors have affected results obtained with the SPME method in the authors’ lab will be given and the appropriateness of the SPME method for the analysis of volatile oxidation products in selected food...

  14. Is Solid Phase Microextraction (SPME) an appropriate method for extraction of volatile oxidation products from complex food systems

    DEFF Research Database (Denmark)

    Jacobsen, Charlotte; Horn, Anna Frisenfeldt; Lu, Henna Fung Sieng

    efficiency obtained with the SPME method can be affected by different factors such as fiber type, stirring of sample versus not stirring, extraction temperature and time. These factors can easily be controlled and optimized to obtain the highest possible extraction efficiency. However, extraction efficiency...... can also be affected by uncontrollable factors such as batch to batch variation between fibers of the same type and presence of compounds in the sample matrix, which competes with the compounds of interest for adsorption to the SPME fiber. The latter factor is particularly a problem when SPME is used...... for analysis of lipid oxidation during storage of complex food matrices. Examples on how uncontrollable factors have affected results obtained with the SPME method in the authors’ lab will be given and the appropriateness of the SPME method for the analysis of volatile oxidation products in selected food...

  15. Use of solid-phase microextraction (SPME) for the determination of methadone and EDDP in human hair by GC-MS.

    Science.gov (United States)

    Lucas, A C; Bermejo, A M; Tabernero, M J; Fernández, P; Strano-Rossi, S

    2000-01-10

    Solid-phase microextraction (SPME) is a new extraction technique with many advantages: small sample volume, simplicity, quickness and solvent-free. It is mainly applied to environmental analysis, but is also useful for the extraction of drugs from biological samples. In this paper the use of SPME is proposed for the determination of methadone and its main metabolite EDDP in hair by GC-MS. The hair samples were washed, cut into 1-mm segments, and incubated with Pronase E for 12 h. A 100-micron polydimethylsiloxane (PDMS) film fibre was submerged for 30 min in a diluted solution of the hydrolysis liquid (1:4 with borax buffer) containing methadone-d3 and EDDP-d3 as internal standards. Once the microextraction was concluded the fibre was directly inserted into the CG injection port. Linearity was found for methadone and EDDP in the range studied, 1.0-50 ng/mg hair, with correlation coefficients higher than 0.99. Interassay relative standard deviation (R.S.D) was determined to be less than 13.30% for methadone and less than 8.94% for EDDP, at 3.0 and 30.0 ng/mg. Analytical recoveries were close to 100% for both compounds on spiked samples. The method was applied to the analysis of real hair samples from eight patients of a methadone maintenance programme. The concentration of methadone in hair ranged from 2.45 to 78.10 ng/mg, and for EDDP from 0.98 to 7.76 ng/mg of hair.

  16. Extração em fase sólida (SPE e micro extração em fase sólida (SPME de piretróides em água Solid-phase extraction (SPE and solid-phase microextraction of pyrethroids in water

    Directory of Open Access Journals (Sweden)

    Wilma Regina Barrionuevo

    2001-04-01

    Full Text Available The pyrethroids bifenthrin, permethrin, cypermethrin and deltamethrin were extracted by solid phase extraction (SPE and solid phase microextraction (SPME. The analysis were performed on a gas chromatograph with electron capture detection (GC-ECD. Octadecil Silano-C18, Florisil and Silica stationary phases were studied for SPE. Better results were obtained for Florisil which gave recoveries from 80% to 108%. Pyrethroids extraction by SPME showed a linear response and a detection limit of 10 pg ml-1. Although the data showed that the two extraction methods were able to isolate the pesticide residues from water samples, the best results were obtained by using SPME which is more sensitive, faster, cheeper, being a more useful technique for the analysis of pyrethroids in drinking water.

  17. Volatiles profiling in medicinal licorice roots using steam distillation and solid-phase microextraction (SPME) coupled to chemometrics.

    Science.gov (United States)

    Farag, Mohamed A; Wessjohann, Ludger A

    2012-11-01

    Licorice (Glycyrrhiza glabra L.) is a plant of considerable commercial importance in traditional medicine and for the flavor and sweets industry. Although Glycyrrhiza species are very competitive targets for phytochemical studies, very little is known about the volatiles composition within that genus, although such knowledge can be suspected to be relevant for understanding the olfactory and taste properties. To provide insight into Glycyrrhiza species aroma composition and for its use in food and pharmaceutical industry, volatile constituents from G. glabra, G. inflata, and G. echinata roots were profiled using steam distillation and solid-phase microextraction. Two phenols, thymol and carvacrol, were found exclusively in essential oil and headspace samples of G. glabra, and with highest amounts for samples that originated from Egypt. In G. echinata oil, (2E, 4E)-decadienal (21%) and β-caryophyllene oxide (24%) were found as main constituents, whereas 1α, 10α-epoxyamorpha-4-ene (13%) and β-dihydroionone (8%) predominated G. inflata. Principal component and hierarchical cluster analyses clearly separated G. echinata and G. inflata from G. glabra; with phenolics and aliphatic aldehydes contributing mostly for species segregation. Licorice (Glycyrrhiza glabra) has large economic, nutritional, and medicinal values. The data presented in this article help in licorice quality control analysis to identify G. glabra from its closely allied species. The presence of thymol and carvacrol exclusively in G. glabra suggests that these volatiles could serve as chemotaxonomic markers and also might be considered as potentially relevant for taste. © 2012 Institute of Food Technologists®

  18. Determination of methyl ethyl ketone in urine samples by headspace solid phase micro extraction (SPME) sampling associated to gas chromatography with flame-ionization detectoR (GC-FID)

    OpenAIRE

    Antunes, Marina Venzon; Linden, Rafael

    2008-01-01

    Methyl ethyl ketone (MEK) is a solvent commonly used in chemical, paint and shoe industry. The aim of this study was to develop and validate a method for urinary quantification of MEK, employing headspace solid phase micro extraction sampling (SPME) coupled to gas chromatography with flame ionization detection (GC-FID). The calibration curve (y=4.6851x-0.0011) presented good linearity with r²=0.9993. Accuracy (94-109%), intra-assay precision (4.07-5.91%) and inter-assay precision (3.03-5.62%)...

  19. Simultaneous analysis of organochlorine pesticides and polychlorinated biphenyls in air samples by using accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) coupled to gas chromatography dual electron capture detection.

    Science.gov (United States)

    Mokbel, Haifaa; Al Dine, Enaam Jamal; Elmoll, Ahmad; Liaud, Céline; Millet, Maurice

    2016-04-01

    An analytical method associating accelerated solvent extraction (ASE) and solid-phase micro-extraction (SPME) in immersion mode combined with gas chromatography dual electrons capture detectors (SPME-GC-2ECD) has been developed and studied for the simultaneous determination of 19 organochlorine pesticides (OCPs) and 22 polychlorinated biphenyls (PCBs) in air samples (active and XAD-2 passive samplers). Samples were extracted with ASE with acetonitrile using the following conditions: temperature, 150 °C; pressure, 1500 psi; static, 15 min; cycles, 3; purge, 300 s; flush, 100 %. Extracts were reduced to 1 mL, and 500 μL of this extract, filled with deionised water, was subject to SPME extraction. Experimental results indicated that the proposed method attained the best extraction efficiency under the optimised conditions: extraction of PCB-OCP mixture using 100-μm PDMS fibre at 80 °C for 40 min with no addition of salt. The performance of the proposed ASE-SPME-GC-2ECD methodology with respect to linearity, limit of quantification and detection was evaluated by spiking of XAD-2 resin with target compounds. The regression coefficient (R (2)) of most compounds was found to be high of 0.99. limits of detection (LODs) are between 0.02 and 4.90 ng m(-3), and limits of quantification (LOQs) are between 0.05 and 9.12 ng m(-3) and between 0.2 and 49 ng/sampler and 0.52 and 91 ng/sampler, respectively, for XAD-2 passive samplers. Finally, a developed procedure was applied to determine selected PCBs and OCPs in the atmosphere.

  20. Analysis of enantiomeric and non-enantiomeric monoterpenes in plant emissions using portable dynamic air sampling/solid-phase microextraction (PDAS-SPME) and chiral gas chromatography/mass spectrometry

    Science.gov (United States)

    Yassaa, Noureddine; Williams, Jonathan

    A portable dynamic air sampler (PDAS) using a porous polymer solid-phase microextraction (SPME) fibre has been validated for the determination of biogenic enantiomeric and non-enantiomeric monoterpenes in air. These compounds were adsorbed in the field, and then thermally desorbed at 250 °C in a gas chromatograph injector port connected via a β-cyclodextrin capillary separating column to a mass spectrometer. The optimized method has been applied for investigating the emissions of enantiomeric monoterpenes from Pseudotsuga menziesii (Douglas-fir), Rosmarinus officinalis (Rosemary) and Lavandula lanata (Lavender) which were selected as representative of coniferous trees and aromatic plants, respectively. The enantiomers of α-pinene, sabinene, camphene, δ-3-carene, β-pinene, limonene, β-phellandrene, 4-carene and camphor were successfully determined in the emissions from the three plants. While Douglas-fir showed a strong predominance toward (-)-enantiomers, Rosemary and Lavender demonstrated a large variation in enantiomeric distribution of monoterpenes. The simplicity, rapidity and sensitivity of dynamic sampling with porous polymer coated SPME fibres coupled to chiral capillary gas chromatography/mass spectrometry (GC/MS) makes this method potentially useful for in-field investigations of atmosphere-biosphere interactions and studies of optically explicit atmospheric chemistry.

  1. SOLID PHASE MICRO EXTRACTION (SPME) FLAVOR ANALYSIS OF APPLE JUICE AND COFFEE MIXTURES USING GAS CHROMATOGRAPHY-MASS SPECTROMETRY (GC-MS)

    OpenAIRE

    Mi Ja Kim; Jeehyun Lee; Jaeyoung Byun; Sunmi Choi; Wonsik Choi

    2016-01-01

    This research was conducted to evaluate the flavor of apple juice and coffee mixtures and the sensory quality of SPME extracts using gas chromatography-mass spectrometry (GC-MS). Three samples with different compositions were examined. Sample A1 contained85% apple juiceand 15% coffee, sample A2 had87.5% apple and 12.5% coffee, and sample A3 had90% apple juiceand 10% coffee. The sensory analysis involved 100 panelists and a sequential monadic test. Sample presentation orders were balanced in ...

  2. Headspace sorptive solid phase microextraction (HS-SPME) combined with a spectrophotometry system: A simple glass devise for extraction and simultaneous determination of cyanide and thiocyanate in environmental and biological samples.

    Science.gov (United States)

    Al-Saidi, H M; Al-Harbi, Sami A; Aljuhani, E H; El-Shahawi, M S

    2016-10-01

    A simple, low cost and efficient headspace sorptive solid phase microextraction (HS-SPME) method for determination of cyanide has been developed. The system comprises of a glass tube with two valves and a moveable glass slide fixed at its centre. It includes an acceptor phase polyurethane foam treated mercury (II) dithizonate [Hg(HDz)2-PUF] complex fixed inside by a septum cap in a cylindrical configuration (5.0cm length and 1.0cm diameter). The extraction is based upon the contact of the acceptor phase to the headspace and subsequently measuring the absorbance of the recovered mercury (II) dithizonate from PUFs sorbent. Unlike other HSSE, extraction and back - extractions was carried out in a closed system, thereby improving the analytical performance by preventing the analyte loss. Under the optimized conditions, a linear calibration plot in the range of 1.0-50.0µmolL(-1) was achieved with limits of detection (LOD) and quantification (LOQ) of 0.34, 1.2µmolL(-1) CN(-), respectively. Simultaneous analysis of cyanide and thiocyanate in saliva was also performed with satisfactory recoveries. Copyright © 2016. Published by Elsevier B.V.

  3. Determination of styrene content in Gorgonzola PDO cheese by headspace solid phase micro-extraction (HS-SPME) and gas-chromatography mass-spectrometry (GC-MS).

    Science.gov (United States)

    Chiesa, L M; Panseri, S; Soncin, S; Vallone, L; Dragoni, I

    2010-06-01

    Control of the composition of products that are intended for use as packaging material is essential, particularly when these products come into direct contact with food. It is well known that plastics are not inert and that their residual monomers, starting substances, and additives are able to migrate into the food they contact. Among plastics, styrene is a common compound found in many plastic containers that can also be produced by the oxidation of Penicillium roqueforti used in gorgonzola Protected Denomination of Origin cheese manufacturing. Therefore, solid-phase microextraction combined with gas chromatography/mass spectrometry was applied in the present work to determine the styrene content in packaged and unpackaged gorgonzola cheese samples to understand styrene migration phenomena from plastic containers.

  4. SPME applied to the study of volatile organic compounds emitted by three species of Eucalyptus in situ. Solid-phase micro extraction.

    Science.gov (United States)

    Zini, Cláudia A; Augusto, Fabio; Christensen, Eva; Caramão, Elina B; Pawliszyn, Janusz

    2002-12-04

    Headspace solid-phase microextraction coupled to gas chromatography/ion trap mass spectrometry-65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) was used to identify and monitor the emission patterns of biogenic volatile organic compounds from leaves of Eucalyptus dunnii, Eucalyptus saligna, and Eucalyptus citriodora in situ. Short extractions (1 min) were performed every 30 min for periods of 8-10 h during 24 days taking advantage of the high capacity of this porous polymer coating. Forty-two compounds were detected and 20 identified in the headspace of E. saligna leaves, and 19 of 27 compounds were identified in the headspace of E. dunnii leaves. The emission pattern of (E)-beta-ocimene and rose oxide suggests that they may play a bioactive role in Eucalyptus.

  5. Influence of harvest maturity and fruit logistics on pineapple (Ananas comosus [L.] Merr.) volatiles assessed by headspace solid phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC/MS).

    Science.gov (United States)

    Steingass, Christof B; Grauwet, Tara; Carle, Reinhold

    2014-05-01

    Profiling of volatiles from pineapple fruits was performed at four ripening stages using headspace solid-phase microextraction and gas chromatography-mass spectrometry (HS-SPME-GC/MS). In total, 142 volatiles were detected, of which 132 were identified. Multivariate data analysis was carried out to assess the effect of post-harvest storage on volatiles composition of green-ripe sea-freighted pineapple in comparison to air-freighted fruits harvested at full maturity. The latter fruits were characterised by volatiles described as potent odorants in pineapples, such as δ-octalactone, γ-lactones, 1-(E,Z)-3,5-undecatriene and 1,3,5,8-undecatetraene, as well as various methyl esters. In contrast, post-harvest storage of green-ripe sea-freighted fruits resulted in an increased formation of ethyl esters, acetates, acetoxy esters and alcohols, thus allowing the authentication of sea- and air-freighted pineapples, respectively. Particularly, compounds presumably derived from methyl-branched amino acid catabolism were identified in the fruits at later post-harvest stages. In addition, physicochemical traits were determined to characterise the fruit maturity stages. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. Quantification of selected volatile organic compounds in human urine by gas chromatography selective reagent ionization time of flight mass spectrometry (GC-SRI-TOF-MS) coupled with head-space solid-phase microextraction (HS-SPME).

    Science.gov (United States)

    Mochalski, Paweł; Unterkofler, Karl

    2016-08-07

    Selective reagent ionization time of flight mass spectrometry with NO(+) as the reagent ion (SRI-TOF-MS(NO(+))) in conjunction with gas chromatography (GC) and head-space solid-phase microextraction (HS-SPME) was used to determine selected volatile organic compounds in human urine. A total of 16 volatiles exhibiting high incidence rates were quantified in the urine of 19 healthy volunteers. Amongst them there were ten ketones (acetone, 2-butanone, 3-methyl-2-butanone, 2-pentanone, 3-methyl-2-pentanone, 4-methyl-2-pentanone, 2-hexanone, 3-hexanone, 2-heptanone, and 4-heptanone), three volatile sulphur compounds (dimethyl sulfide, allyl methyl sulfide, and methyl propyl sulfide), and three heterocyclic compounds (furan, 2-methylfuran, 3-methylfuran). The concentrations of the species under study varied between 0.55 nmol L(-1) (0.05 nmol mmol(-1)creatinine) for allyl methyl sulfide and 11.6 μmol L(-1) (1.54 μmol mmol(-1)creatinine) for acetone considering medians. Limits of detection (LODs) ranged from 0.08 nmol L(-1) for allyl methyl sulfide to 1.0 nmol L(-1) for acetone and furan (with RSDs ranging from 5 to 9%). The presented experimental setup assists both real-time and GC analyses of volatile organic compounds, which can be performed consecutively using the same analytical system. Such an approach supports the novel concept of hybrid volatolomics, an approach which combines VOC profiles obtained from two or more body fluids to improve and complement the chemical information on the physiological status of an individual.

  7. Magnetic in-tube solid phase microextraction.

    Science.gov (United States)

    Moliner-Martínez, Y; Prima-Garcia, Helena; Ribera, Antonio; Coronado, Eugenio; Campíns-Falcó, P

    2012-08-21

    We report a new in-tube solid phase microextraction approach named magnetic in-tube solid phase microextraction, magnetic-IT-SPME. Magnetic-IT-SPME has been developed, taking advantage of magnetic microfluidic principles with the aim to improve extraction efficiency of IT-SPME systems. First, a magnetic hybrid material formed by Fe(3)O(4) nanoparticles supported on SiO(2) was synthesized and immobilized in the surface of a bared fused silica capillary column to obtain a magnetic adsorbent extraction phase. The capillary column was placed inside a magnetic coil that allowed the application of a variable magnetic field. Acetylsalicylic acid, acetaminophen, atenolol, diclofenac, and ibuprofen were tested as target analytes. The application of a controlled magnetic field resulted in quantitative extraction efficiencies of the target analytes between 70 and 100%. These results demonstrated that magnetic forces solve the low extraction efficiency (10-30%) of IT-SPME systems, which is one of their main drawbacks.

  8. Headspace solid-phase microextraction and gas chromatography ...

    African Journals Online (AJOL)

    Purpose: To extract and analyze the volatile components of Chrysanthemum morifolium Ramat. 'huaiju' by headspace solid-phase microextraction (HS-SPME) and gas chromatography–mass spectrometry. (GC–MS). Methods: Volatile components were extracted by HS-SPME and identified by GC–MS. The relative contents ...

  9. Solid-phase microextraction for the analysis of biological samples

    NARCIS (Netherlands)

    Theodoridis, G; Koster, EHM; de Jong, GJ

    2000-01-01

    Solid-phase microextraction (SPME) has been introduced for the extraction of organic compounds from environmental samples. This relatively new extraction technique has now also gained a lot of interest in a broad field of analysis including food, biological and pharmaceutical samples. SPME has a

  10. Headspace solid-phase microextraction and gas chromatography ...

    African Journals Online (AJOL)

    Purpose: To extract and analyze the volatile components of Chrysanthemum morifolium Ramat. 'huaiju' by headspace solid-phase microextraction (HS-SPME) and gas chromatography–mass spectrometry (GC–MS). Methods: Volatile components were extracted by HS-SPME and identified by GC–MS. The relative contents ...

  11. Headspace Solid-Phase Microextraction Coupled with Gas ...

    African Journals Online (AJOL)

    contact temperature measurement system (ONTMS). Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was used to analyze the volatile composition of raw FCP and its various ...

  12. Solid phase microextraction.

    Science.gov (United States)

    Pawliszyn, J

    2001-01-01

    Solid Phase Microextraction (SPME) uses a small volume of sorbent dispersed typically on the surface of small fibres, to isolate and concentrate analytes from sample matrix. After contact with sample, analytes are absorbed or adsorbed by the fibre phase (depending on the nature of the coating) until an equilibrium is reached in the system. The amount of an analyte extracted by the coating at equilibrium is determined by the magnitude of the partition coefficient of the analyte between the sample matrix and the coating material. After the extraction step, the fibres are transferred, with the help of a syringe-like handling device, to analytical instrument, for separation and quantitation of target analytes. This technique integrates sampling, extraction and sample introduction and is a simple way of facilitating on-site monitoring. Applications of this technique include environmental monitoring, industrial hygiene, process monitoring, clinical, forensic, food, flavour, fragrance and drug analyses, in laboratory and on-site analysis.

  13. Feeding Essential Oils and 2-Heptanone in Sugar Syrup and Protein Diets to Honey Bees (Apis mellifera L.) as Potential Varroa Mite (Varroa destructor) Controls and Traced by SPME (Solid Phase Micro Extraction) Fibers

    Science.gov (United States)

    Essential oils and oil components were fed to honey bees in a sugar syrup and liquid protein diet in order to determine if the oils were being incorporated into the bee larvae and could be traced by means of SPME. The compounds used were origanum, 2-heptanone, thymol and connamon oil. The main com...

  14. Improving the On-Line Extraction of Polar Compounds by IT-SPME with Silica Nanoparticles Modified Phases

    Directory of Open Access Journals (Sweden)

    Pascual Serra-Mora

    2018-02-01

    Full Text Available In the present work the extraction efficiency of in-tube solid-phase microextraction (IT-SPME for polar herbicides has been evaluated using extractive capillaries coated with different polymeric sorbents. For this purpose, aqueous solutions of herbicides with a wide range of polarities, including some highly polar compounds (log Kow < 1, have been directly processed by IT-SPME coupled on-line to capillary liquid chromatography with UV-diode array detection. For extraction, commercially available capillary columns coated with polydimethylsiloxane (PDMS and polyetilenglicol (PEG-based phases have been used, and the results have been compared with those obtained with a synthesized tetraethyl orthosilicate (TEOS-trimethoxyethylsilane (MTEOS polymer, as well as the same polymer reinforced with silica nanoparticles (SiO2 NPs. The SiO2 NPs functionalized TEOS-MTEOS coating provided the best results for most herbicides, especially for the most polar compounds. On the basis of the results obtained, conditions for the quantification of the herbicides tested are described using a SiO2 NPs reinforced TEOS-MTEOS coated capillary. The proposed method provided satisfactory linearity up to concentrations of 200 μg/L. The precision was also suitable, with relative standard deviations (RSDs values ≤9% (n = 3, and the limits of detection (LODs were within the 0.5–7.5 µg/L range. The method has been applied to different water samples and the extract obtained from an agricultural soil.

  15. Critical micelle concentration values for different surfactants measured with solid-phase microextraction fibers

    NARCIS (Netherlands)

    Haftka, Joris J H; Scherpenisse, Peter; Oetter, G??nter; Hodges, Geoff; Eadsforth, Charles V.; Kotthoff, Matthias; Hermens, Joop L M

    The amphiphilic nature of surfactants drives the formation of micelles at the critical micelle concentration (CMC). Solid-phase microextraction (SPME) fibres were used in the present study to measure CMC values of twelve nonionic, anionic, cationic and zwitterionic surfactants. The SPME derived CMC

  16. Application of solid-phase microextraction in analytical toxicology.

    Science.gov (United States)

    Pragst, Fritz

    2007-08-01

    Solid-phase microextraction (SPME) is a miniaturized and solvent-free sample preparation technique for chromatographic-spectrometric analysis by which the analytes are extracted from a gaseous or liquid sample by absorption in, or adsorption on, a thin polymer coating fixed to the solid surface of a fiber, inside an injection needle or inside a capillary. In this paper, the present state of practical performance and of applications of SPME to the analysis of blood, urine, oral fluid and hair in clinical and forensic toxicology is reviewed. The commercial coatings for fibers or needles have not essentially changed for many years, but there are interesting laboratory developments, such as conductive polypyrrole coatings for electrochemically controlled SPME of anions or cations and coatings with restricted-access properties for direct extraction from whole blood or immunoaffinity SPME. In-tube SPME uses segments of commercial gas chromatography (GC) capillaries for highly efficient extraction by repeated aspiration-ejection cycles of the liquid sample. It can be easily automated in combination with liquid chromatography but, as it is very sensitive to capillary plugging, it requires completely homogeneous liquid samples. In contrast, fiber-based SPME has not yet been performed automatically in combination with high-performance liquid chromatography. The headspace extractions on fibers or needles (solid-phase dynamic extraction) combined with GC methods are the most advantageous versions of SPME because of very pure extracts and the availability of automatic samplers. Surprisingly, substances with quite high boiling points, such as tricyclic antidepressants or phenothiazines, can be measured by headspace SPME from aqueous samples. The applicability and sensitivity of SPME was essentially extended by in-sample or on-fiber derivatization. The different modes of SPME were applied to analysis of solvents and inhalation narcotics, amphetamines, cocaine and metabolites

  17. Determinação de metil-etil-cetona em amostras de urina com amostragem por micro extração em fase sólida (MEFS em headspace associada à cromatografia gasosa com detector de ionização de chama (CG-DIC Determination of methyl ethyl ketone in urine samples by headspace solid phase micro extraction (SPME sampling associated to gas chromatography with flame-ionization detectoR (GC-FID

    Directory of Open Access Journals (Sweden)

    Marina Venzon Antunes

    2008-01-01

    Full Text Available Methyl ethyl ketone (MEK is a solvent commonly used in chemical, paint and shoe industry. The aim of this study was to develop and validate a method for urinary quantification of MEK, employing headspace solid phase micro extraction sampling (SPME coupled to gas chromatography with flame ionization detection (GC-FID. The calibration curve (y=4.6851x-0.0011 presented good linearity with r²=0.9993. Accuracy (94-109%, intra-assay precision (4.07-5.91% and inter-assay precision (3.03-5.62% were acceptable. The quantification limit was 0.19 mg/L. This low cost method can be used routinely in the biological monitoring of occupational exposure to MEK, according to the requirements of the Brazilian legislation.

  18. Air sampling with solid phase microextraction

    Science.gov (United States)

    Martos, Perry Anthony

    There is an increasing need for simple yet accurate air sampling methods. The acceptance of new air sampling methods requires compatibility with conventional chromatographic equipment, and the new methods have to be environmentally friendly, simple to use, yet with equal, or better, detection limits, accuracy and precision than standard methods. Solid phase microextraction (SPME) satisfies the conditions for new air sampling methods. Analyte detection limits, accuracy and precision of analysis with SPME are typically better than with any conventional air sampling methods. Yet, air sampling with SPME requires no pumps, solvents, is re-usable, extremely simple to use, is completely compatible with current chromatographic equipment, and requires a small capital investment. The first SPME fiber coating used in this study was poly(dimethylsiloxane) (PDMS), a hydrophobic liquid film, to sample a large range of airborne hydrocarbons such as benzene and octane. Quantification without an external calibration procedure is possible with this coating. Well understood are the physical and chemical properties of this coating, which are quite similar to those of the siloxane stationary phase used in capillary columns. The log of analyte distribution coefficients for PDMS are linearly related to chromatographic retention indices and to the inverse of temperature. Therefore, the actual chromatogram from the analysis of the PDMS air sampler will yield the calibration parameters which are used to quantify unknown airborne analyte concentrations (ppb v to ppm v range). The second fiber coating used in this study was PDMS/divinyl benzene (PDMS/DVB) onto which o-(2,3,4,5,6- pentafluorobenzyl) hydroxylamine (PFBHA) was adsorbed for the on-fiber derivatization of gaseous formaldehyde (ppb v range), with and without external calibration. The oxime formed from the reaction can be detected with conventional gas chromatographic detectors. Typical grab sampling times were as small as 5 seconds

  19. Solid-phase microextraction and the human fecal VOC metabolome.

    Directory of Open Access Journals (Sweden)

    Emma Dixon

    2011-04-01

    Full Text Available The diagnostic potential and health implications of volatile organic compounds (VOCs present in human feces has begun to receive considerable attention. Headspace solid-phase microextraction (SPME has greatly facilitated the isolation and analysis of VOCs from human feces. Pioneering human fecal VOC metabolomic investigations have utilized a single SPME fiber type for analyte extraction and analysis. However, we hypothesized that the multifarious nature of metabolites present in human feces dictates the use of several diverse SPME fiber coatings for more comprehensive metabolomic coverage. We report here an evaluation of eight different commercially available SPME fibers, in combination with both GC-MS and GC-FID, and identify the 50/30 µm CAR-DVB-PDMS, 85 µm CAR-PDMS, 65 µm DVB-PDMS, 7 µm PDMS, and 60 µm PEG SPME fibers as a minimal set of fibers appropriate for human fecal VOC metabolomics, collectively isolating approximately 90% of the total metabolites obtained when using all eight fibers. We also evaluate the effect of extraction duration on metabolite isolation and illustrate that ex vivo enteric microbial fermentation has no effect on metabolite composition during prolonged extractions if the SPME is performed as described herein.

  20. Headspace solid-phase microextraction for wine volatile analysis.

    Science.gov (United States)

    Azzi-Achkouty, Samar; Estephan, Nathalie; Ouaini, Naïm; Rutledge, Douglas N

    2017-07-03

    The most commonly used technique to prepare samples for the analysis of wine volatile is the headspace solid-phase microextraction (HS-SPME). This method has gained popularity in last few years, as it is a unique solventless preparation technique. In this paper, a summary of recently published studies using HS-SPME for the analysis of wine aromas, with special emphasis on the method developed, has been compiled. Several papers are discussed in detail, mainly with respect to the SPME conditions used. A brief summary of the reviews related to HS-SPME analysis is given and discussed. Several parameters affecting the HS-SPME, such as the salt concentration and the agitation conditions, are used in the same way as used in several papers. The HS-SPME extraction proved to be sufficiently sensitive to satisfy legislative requirements related to low detection and quantification limits as well as method accuracy and precision requirements. However, in order to achieve the best performance and precision, the protocol needs to be optimized for each case. The effect of different parameters must be well characterized to ensure correct extraction and desorption to ensure the transfer of extracted compounds into the analytical system. The operating parameters, such as time, temperature, and agitation, must then be kept constant for all the samples.

  1. Application of head-space solid-phase microextraction for the analysis of volatile metabolites emitted by Penicillium species

    DEFF Research Database (Denmark)

    Nilsson, Torben; Larsen, Thomas Ostenfeld; Montanarella, Luca

    1996-01-01

    Head-space solid-phase microextraction (HS-SPME) has been used to collect volatile organic compounds (VOCs) emitted from fungi of the genus Penicillium. Gas chromatography combined with mass spectrometry (GC-MS) was employed for the analysis of the profiles of volatile metabolites characteristic ......-SPME has a great potential use in the analysis of biogenic VOC emissions, including chemotaxonomical studies....

  2. Analysis of tetramethylene disulfotetramine in foods using solid-phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    De Jager, Lowri S; Perfetti, Gracia A; Diachenko, Gregory W

    2008-05-23

    An automated solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method for the determination of tetramethylene disulfotetramine in foods was developed. A comparison of direct immersion (DI) and headspace (HS) extraction techniques using a 70microm carbowax/divinylbenzene (CW/DVB) fiber is presented. The optimized DI-SPME method provided an aqueous extraction limit of detection (LOD) of 9.0ng/g while the HS-SPME LOD was 2.7ng/g. In both SPME modes, recovery was highly matrix dependent and quantification requires standard addition calibrations. Analysis of foods using DI-SPME encountered many obstacles including fiber fouling, low recovery and poor reproducibility. HS-SPME was successfully applied to food analysis with minimal interferences. Standard addition calibration curves for foods gave high linearity (R2>0.98), reproducibility (RSD<12%) and sensitivity with LODs ranging from 0.9 to 4.3ng/g.

  3. Comparison of membrane assisted solvent extraction, stir bar sorptive extraction, and solid phase microextraction in analysis of tetramine in food.

    Science.gov (United States)

    De Jager, Lowri S; Perfetti, Gracia A; Diachenko, Gregory W

    2009-04-01

    Three environmentally friendly extraction techniques, membrane assisted solvent extraction (MASE), stir bar sorptive extraction (SBSE), and headspace solid phase microextraction (HS-SPME), were compared for the direct analysis of the highly toxic rodenticide tetramine in food. The optimized MASE method was applied to seven foods fortified with tetramine and compared to previously reported SBSE and HS-SPME results. Parameters such as the standard addition linearity (MASE (0.964-0.999), SBSE (0.966-0.999), HS-SPME (0.955-0.999)), recovery (MASE (12-86%), SBSE (36-130%), HS-SPME (50-200%)), reproducibility (MASE (3.0-30%), SBSE (4.4-9.6%), HS-SPME (1-12%)), and LOD (MASE (1.6-6.4 ng/g), SBSE (0.2-2.1 ng/g), HS-SPME (0.9-4.3 ng/g)) were compared.

  4. UPTAKE OF RADIONUCLIDE METALS BY SPME FIBERS

    Energy Technology Data Exchange (ETDEWEB)

    Duff, M; S Crump, S; Robert02 Ray, R; Keisha Martin, K; Donna Beals, D

    2006-08-28

    The Federal Bureau of Investigation (FBI) Laboratory currently does not have on site facilities for handling radioactive evidentiary materials and there are no established FBI methods or procedures for decontaminating high explosive (HE) and fire debris (FD) evidence while maintaining evidentiary value. One experimental method for the isolation of HE and FD residue involves using solid phase microextraction or SPME fibers to remove residue of interest. Due to their high affinity for organics, SPME fibers should have little affinity for most metals. However, no studies have measured the affinity of radionuclides for SPME fibers. The focus of this research was to examine the affinity of dissolved radionuclide ({sup 239/240}Pu, {sup 238}U, {sup 237}Np, {sup 85}Sr, {sup 133}Ba, {sup 137}Cs, {sup 60}Co and {sup 226}Ra) and stable radionuclide surrogate metals (Sr, Co, Ir, Re, Ni, Ba, Cs, Nb, Zr, Ru, and Nd) for SPME fibers at the exposure conditions that favor the uptake of HE and FD residues. Our results from radiochemical and mass spectrometric analyses indicate these metals have little measurable affinity for these SPME fibers during conditions that are conducive to HE and FD residue uptake with subsequent analysis by liquid or gas phase chromatography with mass spectrometric detection.

  5. Solid phase radioimmunoassays

    International Nuclear Information System (INIS)

    Wide, L.

    1977-01-01

    Solid phase coupled antibodies were introduced to facilitate the separation of bound and free labelled ligand in the competitive inhibition radioimmunoassay. Originally, the solid matrix used was in the form of small particles and since then a number of different matrices have been used such as very fine powder particles, gels, paper and plastic discs, magnetic particles and the inside surface of plastic tubes. The coupling of antibodies may be that of a covalent chemical binding, a strong physical adsorbtion, or an immunological binding to a solid phase coupled antigen. New principles of radioimmunoassay such as the solid phase sandwich techniques and the immunoradiometric assay were developped from the use of solid phase coupled antigens and antibodies. The solid phase sandwich techniques are reagent excess methods with a very wide applicability. Several of the different variants of solid phase techniques are suitable for automation. Advantages and disadvantages of solid phase radioimmunoassays when compared with those using soluble reagents are discussed. (orig.) [de

  6. Determination of parathion in biological fluids by means of direct Solid Phase Microextraction.

    OpenAIRE

    Gallardo, Eugenia; Barroso, Mário; Margalho, C.; Cruz, Angelines; Vieira, Duarte Nuno; López-Rivadulla, Manuel

    2010-01-01

    A new and simple procedure for the determination of parathion in human whole blood and urine using direct immersion (DI) solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. This technique was developed using only 100 ìL of sample, and ethion was used as internal standard (IS). A 65-ìm Carbowax/divinylbenzene (CW/DVB) SPME fibre was selected for sampling, and the main parameters affecting the SPME process such as extraction ...

  7. Critical micelle concentration values for different surfactants measured with solid-phase microextraction fibers.

    Science.gov (United States)

    Haftka, Joris J-H; Scherpenisse, Peter; Oetter, Günter; Hodges, Geoff; Eadsforth, Charles V; Kotthoff, Matthias; Hermens, Joop L M

    2016-09-01

    The amphiphilic nature of surfactants drives the formation of micelles at the critical micelle concentration (CMC). Solid-phase microextraction (SPME) fibers were used in the present study to measure CMC values of 12 nonionic, anionic, cationic, and zwitterionic surfactants. The SPME-derived CMC values were compared to values determined using a traditional surface tension method. At the CMC of a surfactant, a break in the relationship between the concentration in SPME fibers and the concentration in water is observed. The CMC values determined with SPME fibers deviated by less than a factor of 3 from values determined with a surface tension method for 7 out of 12 compounds. In addition, the fiber-water sorption isotherms gave information about the sorption mechanism to polyacrylate-coated SPME fibers. A limitation of the SPME method is that CMCs for very hydrophobic cationic surfactants cannot be determined when the cation exchange capacity of the SPME fibers is lower than the CMC value. The advantage of the SPME method over other methods is that CMC values of individual compounds in a mixture can be determined with this method. However, CMC values may be affected by the presence of compounds with other chain lengths in the mixture because of possible mixed micelle formation. Environ Toxicol Chem 2016;35:2173-2181. © 2016 SETAC. © 2016 SETAC.

  8. Solid-phase microextraction

    DEFF Research Database (Denmark)

    Nilsson, Torben

    and organophosphate pesticides and triazine herbicides together with their metabolites in aqueous samples. SPME combined with gas chromatography proved to be a precise, accurate and sensitive technique for water analysis. Also SPME combined with high performance liquid chromatography was tested, and a method...

  9. Solid phase microextraction speciation analysis of triclosan in aqueous mediacontaining sorbing nanoparticles

    NARCIS (Netherlands)

    Zielinska, K.

    2014-01-01

    Solid phase microextraction (SPME) is applied in the speciation analysis of the hydrophobic compound triclosan in an aqueous medium containing sorbing SiO2 nanoparticles (NPs). It is found that these NPs, as well as their complexes with triclosan, partition between the bulk medium and the solid

  10. Determination of Trichloroethylene in Water by Liquid–Liquid Microextraction Assisted Solid Phase Microextraction

    Directory of Open Access Journals (Sweden)

    Mengliang Zhang

    2015-02-01

    Full Text Available A method for the determination of trichloroethylene (TCE in water using portable gas chromatography/mass spectrometry (GC/MS was developed. A novel sample preparation method, liquid–liquid microextraction assisted solid phase microextraction (LLME–SPME, is introduced. In this method, 20 µL of hexane was added to 10 mL of TCE contaminated aqueous samples to assist headspace SPME. The extraction efficiency of SPME was significantly improved with the addition of minute amounts of organic solvents (i.e., 20 µL hexane. The absolute recoveries of TCE at different concentrations were increased from 11%–17% for the samples extracted by SPME to 29%–41% for the samples extracted by LLME–SPME. The method was demonstrated to be linear from 10 to 1000 ng mL−1 for TCE in water. The improvements on extraction efficiencies were also observed for toluene and 1, 2, 4-trichlorobenzene in water by using LLME–SPME method. The LLME–SPME method was optimized by using response surface modeling (RSM.

  11. Headspace-solid-phase microextraction in the analysis of the volatile fraction of aromatic and medicinal plants.

    Science.gov (United States)

    Belliardo, Flavio; Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara

    2006-08-01

    Headspace (HS)-solid-phase microextraction (SPME) has assumed an ever increasing importance as a technique for HS sampling to study the composition of the HS of medicinal and aromatic plants. HS-SPME has mainly been applied for (a) studying the composition of the volatile fraction, including in addition to or as an alternative to other sampling techniques; (b) monitoring the biological phenomena involved with the volatile fraction of a plant; (c) discriminating between species, subspecies, varieties, cultivars, or chemotypes; and (d) quality control of plant samples. A review of 108 articles published during 2000-2005 is presented covering the use of HS-SPME in the field of aromatic and medicinal plants, selection of the most effective fiber and sampling conditions, comparison of HS-SPME and other volatile fraction sample preparation techniques, and the advantages and limits of HS-SPME when applied to medicinal and aromatic plants.

  12. SIMPLE METHOD FOR ESTIMATING POLYCHLORINATED BIPHENYL CONCENTRATIONS ON SOILS AND SEDIMENTS USING SUBCRITICAL WATER EXTRACTION COUPLED WITH SOLID-PHASE MICROEXTRACTION. (R825368)

    Science.gov (United States)

    A rapid method for estimating polychlorinated biphenyl (PCB) concentrations in contaminated soils and sediments has been developed by coupling static subcritical water extraction with solid-phase microextraction (SPME). Soil, water, and internal standards are placed in a seale...

  13. Comparison of solid-phase microextraction, supercritical fluid extraction, steam distillation, and solvent extraction techniques for analysis of volatile consituents in Fructus Amomi.

    Science.gov (United States)

    Shen, Shun; Sha, Yunfei; Deng, Chunhui; Fu, Daxi; Chen, Jiakuan; Zhang, Xiangmin

    2005-01-01

    Four sampling techniques, solid-phase microextraction (SPME), supercritical fluid extraction (SFE), steam distillation (SD), and solvent extraction (SE), were compared for the analysis of volatile constituents from a traditional Chinese medicine (TCM) of the dried ripe fruit of Fructus Amomi (Sha Ren). A total of 38 compounds were identified by gas chromatography/mass spectrometry. Different SFE and SPME parameters (modifier content, extraction pressure, and temperature for SFE and fibers, extraction temperature, and time for SPME) were studied. The results by SFE and SPME were compared with those obtained by conventional SD and SE methods. The results showed that SFE and SPME are better sample preparation techniques than SD and SE. Due to SFE's requirement for expensive specialized instrumentation, the simplicity, low cost, and speed of SPME make it a more appropriate technique for extraction of volatile constituents in TCMs.

  14. Evaluation of in vivo solid phase microextraction for minimally invasive analysis of nonvolatile phytochemicals in Amazonian plants.

    Science.gov (United States)

    Musteata, Florin Marcel; Sandoval, Manuel; Ruiz-Macedo, Juan C; Harrison, Kathleen; McKenna, Dennis; Millington, William

    2016-08-24

    Although solid phase microextraction (SPME) has been used extensively for fingerprinting volatile compounds emitted by plants, there are very few such reports for direct insertion SPME. In this research, direct contact of SPME probes with the interstitial fluid of plants was investigated as a method for phytochemical analysis. Medicinal plants from the Amazon have been the source of numerous drugs used in western medicine. However, a large number of species used in traditional medicine have not been characterized chemically, partly due to the difficulty of field work. In this project, the phytochemical composition of plants from several genera was fingerprinted by combining convenient field sampling by solid phase microextraction (SPME) with laboratory analysis by LC-MS. The new method was compared with classical sampling followed by liquid extraction (LE). SPME probes were prepared by coating stainless steel wires with a mixture of polyacrylonitrile and either RP-amide or HS-F5 silica particles. Sampling was performed by inserting the microextraction probes into various tissues of living plants in their natural environment. After in vivo extraction, the probes were sealed under vacuum and refrigerated until analyzed. The probes were desorbed in mobile phase and analyzed on a Waters Acquity UPLC with triple quadrupole mass spectrometer in positive ion mode. Twenty Amazonian plant species were sampled and unique metabolomic fingerprints were obtained. In addition, quantitative analysis was performed for previously identified compounds in three species. Comparison of the fingerprints obtained by in vivo SPME with those obtained by LE showed that 27% of the chromatographic features were unique to SPME, 57% were unique to LE, and 16% were common to both methods. In vivo SPME caused minimal damage to the plants, was much faster than traditional liquid extraction, and provided unique fingerprints for all investigated plants. SPME revealed unique chromatographic

  15. Speciation analysis of aqueous nanoparticulate diclofenac complexes by solid-phase microextraction

    NARCIS (Netherlands)

    Zielinska, K.; Leeuwen, van H.P.; Thibault, S.; Town, R.M.

    2012-01-01

    The dynamic sorption of an organic compound by nanoparticles (NPs) is analyzed by solid-phase microextraction (SPME) for the example case of the pharmaceutical diclofenac in dispersions of impermeable (silica, SiO(2)) and permeable (bovine serum albumin, BSA) NPs. It is shown that only the

  16. Determination of lidocaine in plasma by direct solid-phase microextraction combined with gas chromatography

    NARCIS (Netherlands)

    Koster, EHM; Wemes, C; Morsink, JB; de Jong, GJ

    2000-01-01

    Direct-immersion solid-phase microextraction (SPME) has been used to extract the local anesthetic lidocaine from human plasma. A simplified model shows the relationship between the total amount of drug in plasma and the amount of drug extracted. The model takes into account that the drug

  17. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  18. New Methyltrimethoxysilane-(3-Mercaptopropyl)- Trimethoxysilane Coated Hollow Fiber-Solid Phase Micro extraction for Hexanal and Heptanal Analysis

    International Nuclear Information System (INIS)

    Siti Munirah Abd Wahib; Mohd Marsin Sanagi

    2016-01-01

    Determination of volatile organic compounds (VOCs) in various matrices is often accomplished using solid phase micro extraction (SPME) as a superior mode of extraction. Alternatively, another configuration of solid phase micro extraction (SPME) namely hollow fiber-solid phase micro extraction (HF-SPME) is a great approach to redress some limitations of the ordinary SPME fibers including fiber breakage, coating stripping and sample carry over. The HF-SPME technique highlights the use of hollow polypropylene (PP) membrane to hold and protect the adsorbent inside its lumen. Unlike the conventional SPME, the inexpensive HF device can be disposed after single use. Introducing extracting phase via sol-gel technology has gained great interest owing to its simple preparation method and promising way to obtain materials with good characteristics. In the present work, a new hybrid silica material based on methyltrimethoxysilane-(3-mercaptopropyl)trimethoxysilane (MTMOS-MPTMOS) was introduced as a new extractant of HF-SPME and the effectiveness of the proposed method was tested for analysis of hexanal and heptanal as the target VOC analytes. Preparation of the HF-SPME MTMOS-MPTMOS was simple in which the hybrid material was synthesized via sol-gel method and was self-polymerized in small segments of HF. Parameters affecting the efficiency of the HF-SPME MTMOS-MPTMOS in extracting both aldehydes were thoroughly investigated and analyzed by gas chromatography-flame ionization detection (GC-FID). It was found that the highest efficiency was achieved as the extraction was conducted in 30 min at a stirring rate of 1000 rpm in a 10 mL of sample solution whereby the back-extraction was performed via vortex for 3 min using 100 μL methanol as desorption solvent. Under the optimal conditions, linearity was observed over a range of 0.020-10.00 μg mL -1 with detection limits of 0.015 μg mL -1 and 0.010 μg mL -1 for hexanal and heptanal, respectively. The applicability of the HF-SPME

  19. Análise de fármacos em material biológico: acoplamento microextração em fase sólida "no tubo" e cromatografia líquida de alta eficiência Analysis of drugs in biological samples: automated "in-tube" solid-phase microextraction and high performance liquid chromatography

    Directory of Open Access Journals (Sweden)

    Maria Eugênia C. Queiroz

    2005-10-01

    Full Text Available A new solid phase microextraction (SPME system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.

  20. Solid phase transformations

    CERN Document Server

    Čermák, J

    2008-01-01

    This special-topic book, devoted to ""Solid Phase Transformations"" , covers a broad range of phenomena which are of importance in a number of technological processes. Most commercial alloys undergo thermal treatment after casting, with the aim of imparting desired compositions and/or optimal morphologies to the component phases. In spite of the fact that the topic has lain at the center of physical metallurgy for a long time, there are numerous aspects which are wide open to potential investigative breakthroughs. Materials with new structures also stimulate research in the field, as well as n

  1. Solid phase extraction membrane

    Science.gov (United States)

    Carlson, Kurt C [Nashville, TN; Langer, Roger L [Hudson, WI

    2002-11-05

    A wet-laid, porous solid phase extraction sheet material that contains both active particles and binder and that possesses excellent wet strength is described. The binder is present in a relatively small amount while the particles are present in a relatively large amount. The sheet material is sufficiently strong and flexible so as to be pleatable so that, for example, it can be used in a cartridge device.

  2. Analysis of volatile compositions of Magnolia biondii pamp by steam distillation and headspace solid phase micro-extraction.

    Science.gov (United States)

    Zeng, Zhi; Xie, Runqian; Zhang, Tao; Zhang, Han; Chen, Jie Yu

    2011-01-01

    The chemical compositions of volatile components from Magnolia biondii Pamp were determined by steam distillation (SD) and headspace solid phase micro-extraction (HS-SPME) followed by gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) analysis. Fifty-six compounds were identified and the major volatile components were d-camphor (0.18-43.26%), 1,8-cineol (13.23-38.02%), α-terpineol (6.57-12.29%) and α-cadinene (5.53-15.15%). The comparison of the volatile components from M. biondii Pamp harvested in three regions of China was investigated. Also, the comparison of volatile components by SD and HS-SPME methods in term of isolation time, plant-consuming and chemical compositions was discussed as well. The percentages of the volatile components by HS-SPME method were found to be large difference from the corresponding one by SD method. HS-SPME technique was much faster than SD (60 min (HS-SPME)/420 min (SD)). Although the aromatic profiles between HS-SPME and SD methods showed several quantitative differences, HS-SPME may be applied routinely to analyze aromatic and medicinal plants.

  3. Sampling atmospheric pesticides with SPME: Laboratory developments and field study

    Energy Technology Data Exchange (ETDEWEB)

    Wang Junxia [EPCA-Institut des Sciences Moleculaires, UMR 5255 CNRS-Universite Bordeaux 1, ISM, Site universitaire, 24019 Perigueux Cedex (France); Tuduri, Ludovic [EPCA-Institut des Sciences Moleculaires, UMR 5255 CNRS-Universite Bordeaux 1, ISM, Site universitaire, 24019 Perigueux Cedex (France)], E-mail: l.tuduri@ism.u-bordeaux1.fr; Mercury, Maud [EPCA-Institut des Sciences Moleculaires, UMR 5255 CNRS-Universite Bordeaux 1, ISM, Site universitaire, 24019 Perigueux Cedex (France); Universites d' Aix-Marseille I, II et III-CNRS UMR 6264: Laboratoire Chimie Provence, Equipe Instrumentation et Reactivite Atmospherique (IRA), Universite de Provence Centre de Saint Jerome, Avenue Escadrille Normandie Niemen, 13397 Marseille Cedex 20 (France); Millet, Maurice [Centre de Geochimie de la Surface UMR 7517 CNRS-Universite Louis Pasteur (ULP), LPCA, 1 rue Blessig, 67084 Strasbourg Cedex (France); Briand, Olivier [AFSSET, 253 avenue du General Leclerc, 94701 Maisons-Alfort Cedex (France); Montury, Michel [EPCA-Institut des Sciences Moleculaires, UMR 5255 CNRS-Universite Bordeaux 1, ISM, Site universitaire, 24019 Perigueux Cedex (France)

    2009-02-15

    To estimate the atmospheric exposure of the greenhouse workers to pesticides, solid phase microextraction (SPME) was used under non-equilibrium conditions. Using Fick's law of diffusion, the concentrations of pesticides in the greenhouse can be calculated using pre-determined sampling rates (SRs). Thus the sampling rates (SRs) of two modes of SPME in the lab and in the field were determined and compared. The SRs for six pesticides in the lab were 20.4-48.3 mL min{sup -1} for the exposed fiber and 0.166-0.929 mL min{sup -1} for the retracted fiber. In field sampling, two pesticides, dichlorvos and cyprodinil were detected with exposed SPME. SR with exposed SPME for dichlorvos in the field (32.4 mL min{sup -1}) was consistent with that in the lab (34.5 mL min{sup -1}). SR for dichlorvos in the field (32.4 mL min{sup -1}) was consistent with that in the lab (34.5 mL min{sup -1}). The trends of temporal concentration and the inhalation exposure were also obtained. - SPME was proved to be a powerful and simple tool for determining pesticides' atmospheric concentration.

  4. Sampling atmospheric pesticides with SPME: Laboratory developments and field study

    International Nuclear Information System (INIS)

    Wang Junxia; Tuduri, Ludovic; Mercury, Maud; Millet, Maurice; Briand, Olivier; Montury, Michel

    2009-01-01

    To estimate the atmospheric exposure of the greenhouse workers to pesticides, solid phase microextraction (SPME) was used under non-equilibrium conditions. Using Fick's law of diffusion, the concentrations of pesticides in the greenhouse can be calculated using pre-determined sampling rates (SRs). Thus the sampling rates (SRs) of two modes of SPME in the lab and in the field were determined and compared. The SRs for six pesticides in the lab were 20.4-48.3 mL min -1 for the exposed fiber and 0.166-0.929 mL min -1 for the retracted fiber. In field sampling, two pesticides, dichlorvos and cyprodinil were detected with exposed SPME. SR with exposed SPME for dichlorvos in the field (32.4 mL min -1 ) was consistent with that in the lab (34.5 mL min -1 ). SR for dichlorvos in the field (32.4 mL min -1 ) was consistent with that in the lab (34.5 mL min -1 ). The trends of temporal concentration and the inhalation exposure were also obtained. - SPME was proved to be a powerful and simple tool for determining pesticides' atmospheric concentration

  5. Solid phases of tenoxicam.

    Science.gov (United States)

    Cantera, Rodrigo G; Leza, María G; Bachiller, Carmen M

    2002-10-01

    In this report we describe the preparation and characterization of four polymorphic forms of tenoxicam; they are, three 1:1 stoichiometric solvates with acetonitrile, dioxane, and N,N-dimethylformamide, and an amorphous phase obtained by recrystallization in various solvents. Polymorph IV and solvates with dioxane and N,N-dimethylformamide are reported for the first time in this paper. In addition, three solvates were crystallized in acetone, ethyl acetate, and isopropyl alcohol. These solid forms were characterized by X-ray powder diffraction, differential scanning calorimetry, infrared spectroscopy, thermogravimetry, optical microscopy, and elemental analysis. Solid-state properties, intrinsic dissolution rate, and dissolution kinetics from formulated tablets are also provided. Copyright 2002 Wiley-Liss Inc. and the American Pharmaceutical Association

  6. Rapid determination of volatile organic compounds in environmentally hazardous wastewaters using solid phase microextraction

    Energy Technology Data Exchange (ETDEWEB)

    James, K.J.; Stack, M.A. [Ecotoxicology Research Unit, Chemistry Department, Cork RTC, Bishopstown, Cork (Ireland)

    1997-08-01

    Solid phase micro-extraction (SPME) was applied to the determination of volatile organic compounds (VOC) in wastewater discharges. Environmentally significant samples, typical of those subject to regulatory control, were examined and included discharges from pharmaceutical, petrochemical and municipal sewerage treatment plants. Analysis was performed using gas chromatography - mass spectrometry (GC-MS) following sampling using headspace or immersion SPME. Fused silica fibres, coated with either poly(dimethylsiloxane) or poly(acrylate), were examined to determine VOC which included chloroform, saturated carboxylic acids, alkylbenzenes, phenol, benzonitrile and benzofuran. Detection limits varied from 10 to 170 ng/ml and satisfactory relative standard deviations (%RSD < 10) were obtained. For most samples, headspace sampling was preferred to immersion. SPME was found to be a useful technique for the rapid screening of wastewaters for VOC. (orig.) With 2 figs., 3 tabs.

  7. Headspace solid-phase microextraction procedures for gas chromatographic analysis of biological fluids and materials.

    Science.gov (United States)

    Mills, G A; Walker, V

    2000-12-01

    Solid-phase microextraction (SPME) is a new solventless sample preparation technique that is finding wide usage. This review provides updated information on headspace SPME with gas chromatographic separation for the extraction and measurement of volatile and semivolatile analytes in biological fluids and materials. Firstly the background to the technique is given in terms of apparatus, fibres used, extraction conditions and derivatisation procedures. Then the different matrices, urine, blood, faeces, breast milk, hair, breath and saliva are considered separately. For each, methods appropriate for the analysis of drugs and metabolites, solvents and chemicals, anaesthetics, pesticides, organometallics and endogenous compounds are reviewed and the main experimental conditions outlined with specific examples. Then finally, the future potential of SPME for the analysis of biological samples in terms of the development of new devices and fibre chemistries and its coupling with high-performance liquid chromatography is discussed.

  8. Use of solid-phase microextraction for the detection of acetic acid by ion-trap gas chromatography-mass spectrometry and application to indoor levels in museums.

    Science.gov (United States)

    Godoi, Ana F L; Van Vaeck, Luc; Van Grieken, René

    2005-03-04

    A simple and efficient method using solid-phase microextraction (SPME) and gas chromatography-ion trap mass spectrometry (GC-ITMS) was developed for the analysis of acetic acid in air. The choice of the SPME fibre revealed to be critical as well as the sampling and desorption time. A dilution vessel was used for calibration. The precision of the method was found to be 4.7% relative standard deviation (RSD) and the detection limit 5.7 microg m(-3). The SPME-GC-MS technique was applied to the analysis of acetic acid in museum atmospheres.

  9. Solid-phase spectrophotometry

    International Nuclear Information System (INIS)

    Brykina, G.D.; Marchenko, D.Yu.; Shpigun, O.A.

    1995-01-01

    Solid-phase spectrophotometry (SPS), which is based on the direct measurement of light absorption of an ion exchanger containing a substance of interest, was reviewed. Since 1976, it has been known that aborbance of an ion exchanger is directly proportional to the concentration of a particular ion in solution. A similar dependence can also be followed for other sorbents, as well as for foams, membranes, films, etc., which do not exhibit ion exchange properties. One can use absorption, diffuse reflection, and luminescence spectra parameters as an analytical signal. Thus, SPS of ion exchangers is among the analytical techniques that combine the sorption concentration and surface determination of the substance of interest. This review summarizes the advancements in SPS over the last six years and demonstrates the prospects for its development. Special attention is paid to experimental methods for measuring solid-phase absorption and to the basic procedures of sample preparation, including new ones. These two facets are of great importance for obtaining precise results and extending the capabilities of SPS

  10. Polyelectrolyte coatings prevent interferences from charged nanoparticles in SPME speciation analysis

    NARCIS (Netherlands)

    Zielinska, K.; Leeuwen, van H.P.

    2014-01-01

    In this work we present a new approach for protection of the fiber in solid phase microextraction (SPME) from interfering charged particles present in the sample medium. It involves coating of commercial poly(dimethylsiloxane) extraction phase with polyelectrolyte layer composed of

  11. Passive sampling of ambient ozone by solid phase microextraction with on-fiber derivatization.

    Science.gov (United States)

    Lee, I-Su; Tsai, Shih-Wei

    2008-03-10

    The solid phase microextraction (SPME) device with the polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used as a passive sampler for ambient ozone. Both O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) and 1,2-di-(4-pyridyl)ethylene (DPE) were loaded onto the fiber before sampling. The SPME fiber assembly was then inserted into a PTFE tubing as a passive sampler. Known concentrations of ozone around the ambient ground level were generated by a calibrated ozone generator. Laboratory validations of the SPME passive sampler with the direct-reading ozone monitor were performed side-by-side in an exposure chamber at 25 degrees C. After exposures, pyriden-4-aldehyde was formed due to the reaction between DPE and ozone. Further on-fiber derivatizations between pyriden-4-aldehyde and PFBHA were followed and the derivatives, oximes, were then determined by portable gas chromatography with electron capture detector. The experimental sampling rate of the SPME ozone passive sampler was found to be 1.10 x 10(-4) cm(3) s(-1) with detection limit of 58.8 microg m(-3) h(-1). Field validations with both SPME device and the direct-reading ozone monitor were also performed. The correlations between the results from both methods were found to be consistent with r=0.9837. Compared with other methods, the current designed sampler provides a convenient and sensitive tool for the exposure assessments of ozone.

  12. Solid-phase microextraction-based cuticular hydrocarbon profiling for intraspecific delimitation in Acyrthosiphon pisum.

    Directory of Open Access Journals (Sweden)

    Nan Chen

    Full Text Available Insect cuticular hydrocarbons (CHCs play critical roles in reducing water loss and chemical communication. Species-specific CHC profiles have been used increasingly as an excellent character for species classification. However, considerably less is known about their potential for population delimitation within species. The aims of this study were to develop a solid-phase microextraction (SPME-based CHC collection method and to investigate whether CHC profiles could serve as potential chemotaxonomic tools for intraspecific delimitation in Acyrthosiphon pisum. Optimization of fibers for SPME sampling revealed that 7 μm polydimethylsiloxane (PDMS demonstrated the most efficient adsorption of CHCs among five different tested fibers. SPME sampling showed good reproducibility with repeated collections of CHCs from a single aphid. Validation of SPME was performed by comparing CHC profiles with those from conventional hexane extractions. The two methods showed no qualitative differences in CHCs, although SPME appeared to extract relatively fewer short-chained CHCs. While CHC profiles of a given population differed among developmental stages, wing dimorphism types, and host plants, wingless adult aphids showed very low variance in relative proportions of individual CHC components. Reproducibility of CHC profiles was explored further to classify wingless adult morphs of A. pisum from five different geographic regions that showed no variation in mitochondrial COI gene sequences. Our results demonstrate that CHC profiles are useful in intraspecific delimitation in the field of insect chemotaxonomy.

  13. Solid-phase microextraction-based cuticular hydrocarbon profiling for intraspecific delimitation in Acyrthosiphon pisum

    Science.gov (United States)

    Chen, Nan; Bai, Yu; Fan, Yong-Liang

    2017-01-01

    Insect cuticular hydrocarbons (CHCs) play critical roles in reducing water loss and chemical communication. Species-specific CHC profiles have been used increasingly as an excellent character for species classification. However, considerably less is known about their potential for population delimitation within species. The aims of this study were to develop a solid-phase microextraction (SPME)-based CHC collection method and to investigate whether CHC profiles could serve as potential chemotaxonomic tools for intraspecific delimitation in Acyrthosiphon pisum. Optimization of fibers for SPME sampling revealed that 7 μm polydimethylsiloxane (PDMS) demonstrated the most efficient adsorption of CHCs among five different tested fibers. SPME sampling showed good reproducibility with repeated collections of CHCs from a single aphid. Validation of SPME was performed by comparing CHC profiles with those from conventional hexane extractions. The two methods showed no qualitative differences in CHCs, although SPME appeared to extract relatively fewer short-chained CHCs. While CHC profiles of a given population differed among developmental stages, wing dimorphism types, and host plants, wingless adult aphids showed very low variance in relative proportions of individual CHC components. Reproducibility of CHC profiles was explored further to classify wingless adult morphs of A. pisum from five different geographic regions that showed no variation in mitochondrial COI gene sequences. Our results demonstrate that CHC profiles are useful in intraspecific delimitation in the field of insect chemotaxonomy. PMID:28859151

  14. Fast detection of triacetone triperoxide (TATP) from headspace using planar solid-phase microextraction (PSPME) coupled to an IMS detector.

    Science.gov (United States)

    Fan, Wen; Young, Mimy; Canino, Jon; Smith, James; Oxley, Jimmie; Almirall, Jose R

    2012-04-01

    Triacetone triperoxide (TATP) is a high explosive synthesized from easily available reactants making it accessible for illicit uses. In this study, fast detection of TATP is achieved using a novel planar solid-phase microextraction (PSPME) as a preconcentration and sampling device for headspace analysis offering improved sensitivity and reduced sampling time over the conventional fiber-based solid-phase microextraction (SPME) when followed by ion mobility spectrometer (IMS) detection. Quantitation and comparison of the retention capabilities of PSPME as compared to the commercially available SPME were determined using TATP standards and analyzed using gas chromatography-mass spectrometry for SPME analysis and a commercial IMS with no instrumental modification for PSPME. Static and dynamic headspace extractions were used and compared for PSPME extractions, in which low milligram quantities of TATP were detected within 30 s of static mode sampling and less than 5 s in the dynamic mode sampling for PSPME-IMS.

  15. Direct solid-phase microextraction combined with gas and liquid chromatography for the determination of lidocaine in human urine

    NARCIS (Netherlands)

    Koster, E.H M; Hofman, N.S K; de Jong, G.J.

    Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic

  16. Fabrication of novel nanoporous array anodic alumina solid-phase microextraction fiber coating and its potential application for headspace sampling of biological volatile organic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Zhuomin [School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275 (China); Wang Qingtang [Key Laboratory of Analysis and Detection for Food Safety of Ministry of Education, College of Chemistry and Chemical Engineering, Fuzhou University, Fuzhou, Fujian 350002 (China); Li Gongke, E-mail: cesgkl@mail.sysu.edu.cn [School of Chemistry and Chemical Engineering, Sun Yat-sen University, Guangzhou 510275 (China)

    2012-05-21

    Highlights: Black-Right-Pointing-Pointer Nanoporous array anodic alumina (NAAA) SPME coating was originally prepared. Black-Right-Pointing-Pointer NAAA SPME coating achieved excellent enrichment capability and selectivity for VOCs. Black-Right-Pointing-Pointer NAAA SPME coating can be applied for the headspace sampling of biological VOCs. - Abstract: In the study, nanoporous array anodic alumina (NAAA) prepared by a simple, rapid and stable two-step anodic oxidization method was introduced as a novel solid-phase microextraction (SPME) fiber coating. The regular nanoporous array structure and chemical composition of NAAA SPME fiber coating was characterized and validated by scanning electron microscopy and energy dispersive spectroscopy, respectively. Compared with the commercial polydimethylsiloxane (PDMS) SPME fiber coating, NAAA SPME fiber coating achieved the higher enrichment capability (1.7-4.7 folds) for the mixed standards of volatile organic compounds (VOCs). The selectivity for volatile alcohols by NAAA SPME fiber coating demonstrated an increasing trend with the increasing polarity of alcohols caused by the gradually shortening carbon chains from 1-undecanol to 1-heptanol or the isomerization of carbon chains of some typical volatile alcohols including 2-ethyl hexanol, 1-octanol, 2-phenylethanol, 1-phenylethanol, 5-undecanol, 2-undecanol and 1-undecanol. Finally, NAAA SPME fiber coating was originally applied for the analysis of biological VOCs of Bailan flower, stinkbug and orange peel samples coupled with gas chromatography-mass spectrometry (GC-MS) detection. Thirty, twenty-seven and forty-four VOCs of Bailan flower, stinkbug and orange peel samples were sampled and identified, respectively. Moreover, the contents of trace 1-octanol and nonanal of real orange peel samples were quantified for the further method validation with satisfactory recoveries of 106.5 and 120.5%, respectively. This work proposed a sensitive, rapid, reliable and convenient

  17. Fabrication of novel nanoporous array anodic alumina solid-phase microextraction fiber coating and its potential application for headspace sampling of biological volatile organic compounds

    International Nuclear Information System (INIS)

    Zhang Zhuomin; Wang Qingtang; Li Gongke

    2012-01-01

    Highlights: ► Nanoporous array anodic alumina (NAAA) SPME coating was originally prepared. ► NAAA SPME coating achieved excellent enrichment capability and selectivity for VOCs. ► NAAA SPME coating can be applied for the headspace sampling of biological VOCs. - Abstract: In the study, nanoporous array anodic alumina (NAAA) prepared by a simple, rapid and stable two-step anodic oxidization method was introduced as a novel solid-phase microextraction (SPME) fiber coating. The regular nanoporous array structure and chemical composition of NAAA SPME fiber coating was characterized and validated by scanning electron microscopy and energy dispersive spectroscopy, respectively. Compared with the commercial polydimethylsiloxane (PDMS) SPME fiber coating, NAAA SPME fiber coating achieved the higher enrichment capability (1.7–4.7 folds) for the mixed standards of volatile organic compounds (VOCs). The selectivity for volatile alcohols by NAAA SPME fiber coating demonstrated an increasing trend with the increasing polarity of alcohols caused by the gradually shortening carbon chains from 1-undecanol to 1-heptanol or the isomerization of carbon chains of some typical volatile alcohols including 2-ethyl hexanol, 1-octanol, 2-phenylethanol, 1-phenylethanol, 5-undecanol, 2-undecanol and 1-undecanol. Finally, NAAA SPME fiber coating was originally applied for the analysis of biological VOCs of Bailan flower, stinkbug and orange peel samples coupled with gas chromatography–mass spectrometry (GC–MS) detection. Thirty, twenty-seven and forty-four VOCs of Bailan flower, stinkbug and orange peel samples were sampled and identified, respectively. Moreover, the contents of trace 1-octanol and nonanal of real orange peel samples were quantified for the further method validation with satisfactory recoveries of 106.5 and 120.5%, respectively. This work proposed a sensitive, rapid, reliable and convenient analytical method for the potential study of trace and small molecular

  18. Further research on the photo-SPME of triclosan

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Prado, Lucia; Llompart, Maria; Lores, Marta; Fernandez-Alvarez, Maria; Garcia-Jares, Carmen; Cela, Rafael [Universidad de Santiago de Compostela, Departamento de Quimica Analitica, Nutricion y Bromatologia. Facultad de Quimica, Instituto de Investigacion y Analisis Alimentario, Santiago de Compostela (Spain)

    2006-04-15

    In this study the photoinduced degradation of triclosan has been investigated by photo-solid-phase microextraction (photo-SPME). In photo-SPME, photodegradation is carried out on the SPME fibre containing the target compound. Triclosan was extracted from aqueous solutions by use of polydimethylsiloxane SPME fibres and these were subsequently exposed to UV irradiation (power 8 W, wavelength 254 nm) for different times (from 2 to 60 min). The photodegradation kinetics of triclosan were investigated, the photoproducts generated were tentatively identified, and the photochemical behaviour of these products was studied by use of this on-fibre approach followed by gas chromatographic-mass spectrometric analysis. Eight photoproducts were tentatively identified, including chlorinated phenols, chlorohydroxydiphenyl ethers, 2,8-dichlorodibenzo-p-dioxin, and a possible dichlorodibenzodioxin isomer or dichlorohydroxydibenzofuran. The main photodegradation mechanisms were postulated and photodegradation pathways proposed. The effect of pH on triclosan degradation and on triclosan-to-dioxin conversion was also investigated. Triclosan degradation occurred, and generation of 2,8-dichlorodibenzo-p-dioxin was confirmed, throughout the pH range studied (from 3 to 9). (orig.)

  19. Poly(Dimethylsiloxane)-Poly(Vinyl Alcohol) Coated Solid Phase Micro extraction Fiber for Chloropyrifos Analysis

    International Nuclear Information System (INIS)

    Wan Aini Wan Ibrahim; Nor Fairul Zukry Ahmad Rasdy; Norfazilah Muhamad

    2016-01-01

    Traditional liquid - liquid extraction of pesticides consumes large volumes of organic solvent which are hazardous to the operator and is not environment friendly. Solid phase micro extraction (SPME) is a solvent less extraction method which is safer to the operator and is environmental friendly. A sol-gel hybrid fibre coating material, poly(dimethylsiloxane)-poly(vinyl alcohol) (PDMS-PVA) was synthesized and used in head space solid phase micro extraction (HS-SPME) of chloropyrifos. The thickness of the synthesised PDMS-PVA fiber coating was 13.5 μm and it is thermally stable up to 400 degree Celsius. The PDMS-PVA sol-gel hybrid fiber was also stable to two organic solvents tested; acetonitrile and dichloromethane (1 hour dipping) and showed no significant changes in extraction performance for chloropyrifos. Extracted chloropyrifos was analysed using gas chromatography electron capture detector (GC-ECD). Optimum SPME parameters affecting the PDMS-PVA HS-SPME performance namely extraction time (15 min), extraction temperature (50 degree Celsius), desorption time (5 min), desorption temperature (260 degree Celsius) and stirring rate (120 rpm) were used for extraction. It was found that HSSPME using PDMS-PVA sol-gel fiber gave significantly better extraction performance of chloropyrifos compared to commercial 100 μm PDMS fiber. The PDMS-PVA fiber showed excellent operational performances such as temperature stability (up to 380 degree Celsius), coating lifetime (up to 170 times use) and organic solvent stability. The PDMS-PVA-HS-SPME method showed excellent recovery for chloropyrifos from tomatoes (98.0 %, 5.9 % RSD) at 0.01 μg/ g spiked level (5 times lower than maximum residue limit set by European Union). (author)

  20. Cold fiber solid-phase microextraction device based on thermoelectric cooling of metal fiber.

    Science.gov (United States)

    Haddadi, Shokouh Hosseinzadeh; Pawliszyn, Janusz

    2009-04-03

    A new cold fiber solid-phase microextraction device was designed and constructed based on thermoelectric cooling. A three-stage thermoelectric cooler (TEC) was used for cooling a copper rod coated with a poly(dimethylsiloxane) (PDMS) hollow fiber, which served as the solid-phase microextraction (SPME) fiber. The copper rod was mounted on a commercial SPME plunger and exposed to the cold surface of the TEC, which was enclosed in a small aluminum box. A heat sink and a fan were used to dissipate the generated heat at the hot side of the TEC. By applying an appropriate dc voltage to the TEC, the upper part of the copper rod, which was in contact to the cold side of the TEC, was cooled and the hollow fiber reached a lower temperature through heat transfer. A thermocouple was embedded in the cold side of the TEC for indirect measurement of the fiber temperature. The device was applied in quantitative analysis of off-flavors in a rice sample. Hexanal, nonanal, and undecanal were chosen as three off-flavors in rice. They were identified according to their retention times and analyzed by GC-flame ionization detection instrument. Headspace extraction conditions (i.e., temperature and time) were optimized. Standard addition calibration graphs were obtained at the optimized conditions and the concentrations of the three analytes were calculated. The concentration of hexanal was also measured using a conventional solvent extraction method (697+/-143ng/g) which was comparable to that obtained from the cold fiber SPME method (644+/-8). Moreover, the cold fiber SPME resulted in better reproducibility and shorter analysis time. Cold fiber SPME with TEC device can also be used as a portable device for field sampling.

  1. Comparison of solid phase microextraction and hollow fiber liquid phase microextraction for the determination of pesticides in aqueous samples by gas chromatography triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Garrido Frenich, Antonia; Romero-González, R; Martínez Vidal, José Luis; Martínez Ocaña, R; Baquero Feria, P

    2011-02-01

    This work compares two miniaturised sample preparation methods, solid phase microextraction (SPME) and hollow fiber liquid phase microextraction (HF-LPME), in combination with gas chromatography coupled to tandem mass spectrometry with a triple quadrupole analyzer for the determination of 77 pesticides in drinking water. In the case of SPME, extraction temperature and time were optimized by experimental design, although other parameters, as desorption time, pH, and ionic strength, were also evaluated. The extraction and desorption solvents [octanol/dihexyl ether (75:25, v/v) and cyclohexane, respectively], as well as the extraction and desorption time, ionic strength, and pH, were studied for the HF-LPME procedure. Under the optimal conditions, recoveries (70.2-113.5% for SPME and 70.0-119.5% for HF-LPME), intra-day precision (2.1-19.4% for SPME and 4.3-22.5% for HF-LPME), inter-day precision (5.2-21.5% for SPME and 8.4-27.3% for HF-LPME), and limits of detection, between 0.1 and 28.8 ng/L for SPME and 0.2 and 47.1 ng/L for HF-LPME and overall uncertainty (9.6-25.2% for SPME and 13.3-27.5% for HF-LPME) were established for both extraction procedures. Finally, the proposed methods were successfully applied to the analysis of 41 drinking water samples, and similar results were obtained with both extraction approaches.

  2. Determination of steroids, caffeine and methylparaben in water using solid phase microextraction-comprehensive two dimensional gas chromatography-time of flight mass spectrometry.

    Science.gov (United States)

    Lima Gomes, Paulo C F; Barnes, Brian B; Santos-Neto, Álvaro J; Lancas, Fernando M; Snow, Nicholas H

    2013-07-19

    Analysis of several emerging contaminants (steroids, caffeine and methylparaben) in water using automated solid-phase microextraction with comprehensive two dimensional gas chromatography coupled to time of flight mass spectrometry (SPME-GCxGC-ToF/MS) is presented. Experimental design was used to determine the best SPME extraction conditions and the steroids were not derivatized prior to injection. SPME-GCxGC-ToF/MS provided linear ranges from 0.6 to 1200μgL(-1) and limits of detection and quantitation from 0.02 to 100μgL(-1). A series of river water samples obtained locally were subjected to analysis. SPME-GCxGC-ToF/MS is readily automated, straightforward and competitive with other methods for low level analysis of emerging contaminants. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. [Analysis of volatile components in Qingshanlvshui tea using solid-phase microextraction/accelerated solvent extraction-gas chromatography-mass spectrometry].

    Science.gov (United States)

    Zhan, Jiafen; Lu, Sheming; Meng, Zhaoyu; Xiang, Nengjun; Cao, Qiu'e; Miao, Mingming

    2008-05-01

    The volatile components of Qingshanlvshui Tea were extracted using solid phase micro-extraction (SPME) and accelerated solvent extraction (ASE), and then were identified by gas chromatography-mass spectrometry (GC-MS). It showed that ninety-one compounds were identified, including forty-nine by SPME, fifty-six by ASE, and fourteen by both of them. The main constituents were beta-myrcene, 3,5,5-trimethyl-1,5-heptadiene, L-limonene, alpha-ocimene, beta-ocimene, beta-pinene, 2-methylbenzaldehyde, 5-(hydroxymethyl)-2-furfural. Both SPME and ASE have their advantages. SPME is excellent at simplicity, rapidity, solvent-free, high enrichment, low detection limit, environment friendly etc. ASE has characteristics of time and solvent saving, automation, simplicity, as well as high efficiency.

  4. SOLID PHASE MICROEXTRACTION SAMPLING OF HIGH EXPLOSIVE RESIDUES IN THE PRESENCE OF RADIONUCLIDES AND RADIONUCLIDE SURROGATE METALS

    Energy Technology Data Exchange (ETDEWEB)

    Duff, M; S Crump, S; Robert02 Ray, R; Donna Beals, D

    2007-04-13

    The Federal Bureau of Investigation (FBI) Laboratory currently does not have on site facilities for handling radioactive evidentiary materials and there are no established FBI methods or procedures for decontaminating high explosive (HE) evidence while maintaining evidentiary value. One experimental method for the isolation of HE residue involves using solid phase microextraction or SPME fibers to remove residue of interest. Due to their high affinity for organics, SPME fibers should have little affinity for most metals. However, no studies have measured the affinity of radionuclides for SPME fibers. The focus of this research was to examine the affinity of dissolved radionuclide ({sup 239/240}Pu, {sup 238}U, {sup 237}Np, {sup 85}Sr, {sup 133}Ba, {sup 137}Cs, {sup 60}Co and {sup 226}Ra) and stable radionuclide surrogate metals (Sr, Co, Ir, Re, Ni, Ba, Cs, Nb, Zr, Ru, and Nd) for SPME fibers at the exposure conditions that favor the uptake of HE residues. Our results from radiochemical and mass spectrometric analyses indicate these metals have little measurable affinity for these SPME fibers during conditions that are conducive to HE residue uptake with subsequent analysis by liquid or gas phase chromatography with mass spectrometric detection.

  5. Identification of Flavor Components in Perfumes by Headspace Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry

    Science.gov (United States)

    Knupp, Gerd; Kusch, Peter; Neugebauer, Michael

    2002-01-01

    An experiment for identification of flavor components in Original Eau de Cologne by headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS) with electron impact ionization was developed. A new SPME fiber with a dual coating of divinylbenzene and Carboxen, each suspended in polydimethylsiloxane, was used. The compounds were identified by search of the NIST 98 MS Library or by comparison with pure standards. The experiment was developed for second-year chemistry students to learn the principles of analytical instrumentation (GC-MS) and sample preparation techniques (HS-SPME). The students are able to complete this experiment in a single four-hour laboratory session.

  6. Screening for sarin in air and water by solid-phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Schneider, J F; Boparai, A S; Reed, L L

    2001-10-01

    A method of screening air and water samples for the chemical-warfare agent Sarin is developed using solid-phase microextraction (SPME)-gas chromatography (GC)-mass spectrometry (MS). The SPME field kit sampler is ideal for collecting air and water samples in the field and transporting samples safely to the laboratory. The sampler also allows the sample to be introduced into the GC-MS system without further sample preparation. Results of the tests with Sarin using the SPME technique indicate that a sample collection time of 5 min is sufficient to detect 100 ng/L of Sarin in air. For water samples, Sarin is detected at a concentration of 12 microg/mL or higher. This method is ideal for screening samples for quick response situations.

  7. Quantitative Determination of Caffeine in Beverages Using a Combined SPME-GC/MS Method

    Science.gov (United States)

    Pawliszyn, Janusz; Yang, Min J.; Orton, Maureen L.

    1997-09-01

    Solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) has been applied to the analysis of various caffeinated beverages. Unlike the current methods, this technique is solvent free and requires no pH adjustments. The simplicity of the SPME-GC/MS method lends itself to a good undergraduate laboratory practice. This publication describes the analytical conditions and presents the data for determination of caffeine in coffee, tea, and coke. Quantitation by isotopic dilution is also illustrated.

  8. Identification of volatile compounds in Chrysanthemum morifolium by microwave distillation solid-phase microextraction coupled with GC/MS.

    Science.gov (United States)

    Zhou, Tao; Yang, Bei; Zhang, Haiying; Yu, Yingjia; Chen, Bin; Chen, Yile; Duan, Gengli

    2009-01-01

    Microwave distillation with concomitant solid-phase microextraction (MD-SPME) coupled with GC/MS was developed for identifying volatile compounds in the dried flowers of Chrysanthemum morifolium (CM). Different experimental parameters, including SPME fiber coating, microwave power, irradiation time, and water volume were optimized. The best results were obtained using carboxen/polydimethylsiloxane fiber with microwave irradiation at 400 W for 3 min and the addition of 1 mL water into 1.0 g sample. The proposed method allowed the isolation, extraction, and concentration of volatile compounds to be completed in a single step. This MD-SPME-GC/MS method has also been compared to the conventional steam distillation method followed by GC/MS for this identification. Thirty-two volatile compounds were identified using the newly developed MD-SPME-GC/MS process. Relative standard deviation values of steam distillation-GC/MS. Therefore, the proposed MD-SPME-GC/MS method is simple, rapid, and efficient for identifying volatile compounds in CM.

  9. Quantification of synthetic organic chemicals in biological treatment process effluent using solid-phase microextraction and gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Magbanua, B.S. Jr.; Mitchell, D.R.; Fehniger, S.M.; Bowyer, R.L.; Grady, C.P.L. Jr.

    2000-02-01

    Solid-phase microextraction (SPME), a technique that uses a polymer-coated, fused-silica fiber to selectively extract organic analyses from a sample matrix, followed by gas chromatography (GC), was used to quantify selected synthetic organic chemicals (SOCs) in biological reactor effluent. By selecting an appropriate combination of SPME fiber, GC column, and GC detector, assays to quantify either a suite of SOCs or single selected SOCs were developed. Phenol, 4-chlorophenol, 2-nitrophenol, 4-nitrophenol, 2,4,-dinitrophenol, isophorone, m-toluate, m-sylene, and di-n-butylphthalate were quantified simultaneously using an 85-{micro}m polyacrylate SPME fiber, a 5% diphenyl-95% dimethyl polysiloxane capillary column, and a flame ionization detector. m-Xylene was quantified using a 100-{micro}m polydimethylsiloxane SPME fiber, a 5% diphenyl-95% dimethyl polysiloxane capillary column, and a mass spectrometric detector. Dichloromethane was quantified using an 85-{micro}m polyacrylate SPME fiber, a Carbopack B/1% SP-1000 packed column, and an electron capture detector. All three assays enabled detection of the target analyses to low concentrations ({micro}g/L) with minimal sample volume and processing requirements.

  10. Introduction of coiled solid phase microextraction fiber coated by mesoporous silica/cetyltrimethylammonium bromide for ultra-trace environmental analysis.

    Science.gov (United States)

    Razmi, Habib; Khosrowshahi, Elnaz Marzi; Farrokhzadeh, Samaneh

    2017-07-14

    In this study, a tiny coiled cupper wire as a novel solid phase microextraction (SPME) fiber was coated with mesoporous silica/cetyltrimethylammonium bromide (MCM-41/CTAB) as an adsorbent by electrochemically assisted self-assembly method and used for the preconcentration of polycyclic aromatic hydrocarbons (PAHs) as model analytes prior to chromatographic determination. Deposition of MCM-41/CTAB on the coiled SPME (C-SPME) fiber resulted in easily controlled and reproducible SPME coatings. Non-calcined MCM-41/CTAB on C-SPME plays a key role in the adsorption of PAHs. Under the optimized experimental conditions, low detection limits (36-1220pgL -1 ), and wide linear dynamic ranges (R 2 >0.98) were achieved in the range of 0.25-25,000, 0.12-15,000, 0.56-32,000, 4.1-100,000ngL -1 for phenanthrene, anthracene, fluoranthene and pyrene respectively. The reusability of proposed fiber as well as relative standard deviations for repetitive determination of the target analytes was evaluated. The proposed method was successfully applied for determination of PAHs in several real samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Multiple headspace-solid-phase microextraction: An application to quantification of mushroom volatiles

    International Nuclear Information System (INIS)

    Costa, Rosaria; Tedone, Laura; De Grazia, Selenia; Dugo, Paola; Mondello, Luigi

    2013-01-01

    Highlights: ► Multiple headspace extraction-solid phase microextraction (MHS-SPME) has been applied to the analysis of Agaricus bisporus. ► Mushroom flavor is characterized by the presence of compounds with a 8-carbon atoms skeleton. ► Formation of 8-carbon compounds involves a unique fungal biochemical pathway. ► The MHS-SPME allowed to determine quantitatively 5 target analytes of A. bisporus for the first time. -- Abstract: Multiple headspace-solid phase microextraction (MHS-SPME) followed by gas chromatography/mass spectrometry (GC–MS) and flame ionization detection (GC–FID) was applied to the identification and quantification of volatiles released by the mushroom Agaricus bisporus, also known as champignon. MHS-SPME allows to perform quantitative analysis of volatiles from solid matrices, free of matrix interferences. Samples analyzed were fresh mushrooms (chopped and homogenized) and mushroom-containing food dressings. 1-Octen-3-ol, 3-octanol, 3-octanone, 1-octen-3-one and benzaldehyde were common constituents of the samples analyzed. Method performance has been tested through the evaluation of limit of detection (LoD, range 0.033–0.078 ng), limit of quantification (LoQ, range 0.111–0.259 ng) and analyte recovery (92.3–108.5%). The results obtained showed quantitative differences among the samples, which can be attributed to critical factors, such as the degree of cell damage upon sample preparation, that are here discussed. Considerations on the mushrooms biochemistry and on the basic principles of MHS analysis are also presented

  12. Multiple headspace-solid-phase microextraction: An application to quantification of mushroom volatiles

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Rosaria; Tedone, Laura; De Grazia, Selenia [Dipartimento Farmaco-chimico, University of Messina, viale Annunziata, 98168 Messina (Italy); Dugo, Paola [Dipartimento Farmaco-chimico, University of Messina, viale Annunziata, 98168 Messina (Italy); Centro Integrato di Ricerca (C.I.R.), Università Campus-Biomedico, Via Álvaro del Portillo, 21, 00128 Roma (Italy); Mondello, Luigi, E-mail: lmondello@unime.it [Dipartimento Farmaco-chimico, University of Messina, viale Annunziata, 98168 Messina (Italy); Centro Integrato di Ricerca (C.I.R.), Università Campus-Biomedico, Via Álvaro del Portillo, 21, 00128 Roma (Italy)

    2013-04-03

    Highlights: ► Multiple headspace extraction-solid phase microextraction (MHS-SPME) has been applied to the analysis of Agaricus bisporus. ► Mushroom flavor is characterized by the presence of compounds with a 8-carbon atoms skeleton. ► Formation of 8-carbon compounds involves a unique fungal biochemical pathway. ► The MHS-SPME allowed to determine quantitatively 5 target analytes of A. bisporus for the first time. -- Abstract: Multiple headspace-solid phase microextraction (MHS-SPME) followed by gas chromatography/mass spectrometry (GC–MS) and flame ionization detection (GC–FID) was applied to the identification and quantification of volatiles released by the mushroom Agaricus bisporus, also known as champignon. MHS-SPME allows to perform quantitative analysis of volatiles from solid matrices, free of matrix interferences. Samples analyzed were fresh mushrooms (chopped and homogenized) and mushroom-containing food dressings. 1-Octen-3-ol, 3-octanol, 3-octanone, 1-octen-3-one and benzaldehyde were common constituents of the samples analyzed. Method performance has been tested through the evaluation of limit of detection (LoD, range 0.033–0.078 ng), limit of quantification (LoQ, range 0.111–0.259 ng) and analyte recovery (92.3–108.5%). The results obtained showed quantitative differences among the samples, which can be attributed to critical factors, such as the degree of cell damage upon sample preparation, that are here discussed. Considerations on the mushrooms biochemistry and on the basic principles of MHS analysis are also presented.

  13. Application of Microextraction Techniques Including SPME and MESI to the Thermal Degradation of Polymers: A Review.

    Science.gov (United States)

    Kaykhaii, Massoud; Linford, Matthew R

    2017-03-04

    Here, we discuss the newly developed micro and solventless sample preparation techniques SPME (Solid Phase Microextraction) and MESI (Membrane Extraction with a Sorbent Interface) as applied to the qualitative and quantitative analysis of thermal oxidative degradation products of polymers and their stabilizers. The coupling of these systems to analytical instruments is also described. Our comprehensive literature search revealed that there is no previously published review article on this topic. It is shown that these extraction techniques are valuable sample preparation tools for identifying complex series of degradation products in polymers. In general, the number of products identified by traditional headspace (HS-GC-MS) is much lower than with SPME-GC-MS. MESI is particularly well suited for the detection of non-polar compounds, therefore number of products identified by this technique is not also to the same degree of SPME. Its main advantage, however, is its ability of (semi-) continuous monitoring, but it is more expensive and not yet commercialized.

  14. Head-Space Solid Phase Micro-extraction Followed by GC/MS Analysis of the Volatile Components in Seeds of Cinnamonum camphora

    OpenAIRE

    Yang Yong; Tao Wenyi

    2005-01-01

    The volatile components in seeds of Cinnamomum camphora were analyzed by Solid Phase Micro-extraction (SPME) combined with GC/MS. Twenty four main kinds of volatile compounds, among which the Sesquiterpene (29%), 3-Hexen-2-one (25%) and Monoterpene (10.22%), were separated and analyzed.

  15. Negligible depletion solid-phase microextraction with radiolabeled analytes to study free concentrations and protein binding : an example with [3H]Estradiol

    NARCIS (Netherlands)

    Heringa, M.B.; Pastor, D.; Algra, J.; Vaes, W.H.J.; Hemmens, J.L.M.

    2002-01-01

    A new method is presented that enables sensitive measurement of free concentrations of radiolabeled ligands. Additionally, protein binding of radiochemicals in complex matrixes can be determined with this new technique that combines negligible depletion solid-phase microextraction (nd-SPME) with

  16. Field measurements of biogenic volatile organic compounds in the atmosphere using solid-phase microextraction Arrow

    Science.gov (United States)

    Feijó Barreira, Luís Miguel; Duporté, Geoffroy; Rönkkö, Tuukka; Parshintsev, Jevgeni; Hartonen, Kari; Hyrsky, Lydia; Heikkinen, Enna; Jussila, Matti; Kulmala, Markku; Riekkola, Marja-Liisa

    2018-02-01

    Biogenic volatile organic compounds (BVOCs) emitted by terrestrial vegetation participate in a diversity of natural processes. These compounds impact both short-range processes, such as on plant protection and communication, and long-range processes, for example by participating in aerosol particle formation and growth. The biodiversity of plant species around the Earth, the vast assortment of emitted BVOCs, and their trace atmospheric concentrations contribute to the substantial remaining uncertainties about the effects of these compounds on atmospheric chemistry and physics, and call for the development of novel collection devices that can offer portability with improved selectivity and capacity. In this study, a novel solid-phase microextraction (SPME) Arrow sampling system was used for the static and dynamic collection of BVOCs from a boreal forest, and samples were subsequently analyzed on site by gas chromatography-mass spectrometry (GC-MS). This system offers higher sampling capacity and improved robustness when compared to traditional equilibrium-based SPME techniques, such as SPME fibers. Field measurements were performed in summer 2017 at the Station for Measuring Ecosystem-Atmosphere Relations (SMEAR II) in Hyytiälä, Finland. Complementary laboratory tests were also performed to compare the SPME-based techniques under controlled experimental conditions and to evaluate the effect of temperature and relative humidity on their extraction performance. The most abundant monoterpenes and aldehydes were successfully collected. A significant improvement on sampling capacity was observed with the new SPME Arrow system over SPME fibers, with collected amounts being approximately 2 × higher for monoterpenes and 7-8 × higher for aldehydes. BVOC species exhibited different affinities for the type of sorbent materials used (polydimethylsiloxane (PDMS)-carbon wide range (WR) vs. PDMS-divinylbenzene (DVB)). Higher extraction efficiencies were obtained with dynamic

  17. Solid-phase peptide synthesis

    DEFF Research Database (Denmark)

    Jensen, Knud Jørgen

    2013-01-01

    This chapter provides an introduction to and overview of peptide chemistry with a focus on solid-phase peptide synthesis. The background, the most common reagents, and some mechanisms are presented. This chapter also points to the different chapters and puts them into perspective....

  18. Determination of Atrazine, Acetochlor, Clomazone, Pendimethalin and Oxyfluorfen in Soil by a Solid Phase Microextraction Method

    Directory of Open Access Journals (Sweden)

    Rada Đurović

    2008-01-01

    Full Text Available A solid phase microextraction (SPME method for simultaneous determination of atrazine, acetochlor, clomazone, pendimethalin and oxyfluorfen in soil samples was developed. The method is based on a combination of conventional liquid-solid procedure and a following SPME determination of the selected pesticides. Initially, various microextraction conditions, such as the fibre type, desorption temperature and time, extraction time and NaCl content, were investigated and optimized. Then, extraction efficiencies of severalsolvents (water, hexane, acetonitrile, acetone and methanol and the optimum number of extraction steps within the sample preparation step were optimized. According to the results obtained in these two sets of experiments, two successive extractions with methanol as the extraction solvent were the optimal sample preparation procedure, while the following conditions were found to be most efficient for SPME measurements: 100 μm PDMS fibre, desorption for 7 min at 2700C, 30 min extraction time and 5% NaCl content (w/v. Detection and quantification were done by gas chromatography-mass spectrometry(GC/MS. Relative standard deviation (RSD values for multiple analysis of soil samples fortified at 30 μg/kg of each pesticide were below 19%. Limits of detection (LOD for all the compounds studied were less than 2 μg/kg.

  19. Characterization of Fish Sauce Aroma Impact Compounds Using GC-MS, SPME-Osme-GCO, and Stevens' Power Law Exponents

    Science.gov (United States)

    The objectives of this study were to characterize volatile compounds and to determine the characteristic aromas associated with impact compounds in 4 fish sauces using solid-phase micro-extraction, gas chromatography-mass spectrometry, Osme, and gas chromatography olfactometry (SPME-Osme-GCO) couple...

  20. Second order kinetic modeling of headspace solid phase microextraction of flavors released from selected food model systems.

    Science.gov (United States)

    Zhang, Jiyuan; Cheong, Mun-Wai; Yu, Bin; Curran, Philip; Zhou, Weibiao

    2014-09-04

    The application of headspace-solid phase microextraction (HS-SPME) has been widely used in various fields as a simple and versatile method, yet challenging in quantification. In order to improve the reproducibility in quantification, a mathematical model with its root in psychological modeling and chemical reactor modeling was developed, describing the kinetic behavior of aroma active compounds extracted by SPME from two different food model systems, i.e., a semi-solid food and a liquid food. The model accounted for both adsorption and release of the analytes from SPME fiber, which occurred simultaneously but were counter-directed. The model had four parameters and their estimated values were found to be more reproducible than the direct measurement of the compounds themselves by instrumental analysis. With the relative standard deviations (RSD) of each parameter less than 5% and root mean square error (RMSE) less than 0.15, the model was proved to be a robust one in estimating the release of a wide range of low molecular weight acetates at three environmental temperatures i.e., 30, 40 and 60 °C. More insights of SPME behavior regarding the small molecule analytes were also obtained through the kinetic parameters and the model itself.

  1. Second Order Kinetic Modeling of Headspace Solid Phase Microextraction of Flavors Released from Selected Food Model Systems

    Directory of Open Access Journals (Sweden)

    Jiyuan Zhang

    2014-09-01

    Full Text Available The application of headspace-solid phase microextraction (HS-SPME has been widely used in various fields as a simple and versatile method, yet challenging in quantification. In order to improve the reproducibility in quantification, a mathematical model with its root in psychological modeling and chemical reactor modeling was developed, describing the kinetic behavior of aroma active compounds extracted by SPME from two different food model systems, i.e., a semi-solid food and a liquid food. The model accounted for both adsorption and release of the analytes from SPME fiber, which occurred simultaneously but were counter-directed. The model had four parameters and their estimated values were found to be more reproducible than the direct measurement of the compounds themselves by instrumental analysis. With the relative standard deviations (RSD of each parameter less than 5% and root mean square error (RMSE less than 0.15, the model was proved to be a robust one in estimating the release of a wide range of low molecular weight acetates at three environmental temperatures i.e., 30, 40 and 60 °C. More insights of SPME behavior regarding the small molecule analytes were also obtained through the kinetic parameters and the model itself.

  2. Detection of Methyl Salicylate Transforted by Honeybees (Apis mellifera) Using Solid Phase Microextration (SPME) Fibers; TOPICAL

    International Nuclear Information System (INIS)

    BENDER, SUSAN FAE ANN; RODACY, PHILIP J.; BARNETT, JAMES L.; BENDER, GARY L.

    2001-01-01

    The ultimate goal of many environmental measurements is to determine the risk posed to humans or ecosystems by various contaminants. Conventional environmental monitoring typically requires extensive sampling grids covering several media including air, water, soil and vegetation. A far more efficient, innovative and inexpensive tactic has been found using honeybees as sampling mechanisms. Members from a single bee colony forage over large areas ((approx)2 x 10(sup 6) m(sup 2)), making tens of thousands of trips per day, and return to a fixed location where sampling can be conveniently conducted. The bees are in direct contact with the air, water, soil and vegetation where they encounter and collect any contaminants that are present in gaseous, liquid and particulate form. The monitoring of honeybees when they return to the hive provides a rapid method to assess chemical distributions and impacts (1). The primary goal of this technology is to evaluate the efficiency of the transport mechanism (honeybees) to the hive using preconcentrators to collect samples. Once the extent and nature of the contaminant exposure has been characterized, resources can be distributed and environmental monitoring designs efficiently directed to the most appropriate locations. Methyl salicylate, a chemical agent surrogate was used as the target compound in this study

  3. Detection of Methyl Salicylate Transforted by Honeybees (Apis mellifera) Using Solid Phase Microextration (SPME) Fibers

    Energy Technology Data Exchange (ETDEWEB)

    BENDER, SUSAN FAE ANN; RODACY, PHILIP J.; BARNETT, JAMES L.; BENDER, GARY L.

    2001-12-01

    The ultimate goal of many environmental measurements is to determine the risk posed to humans or ecosystems by various contaminants. Conventional environmental monitoring typically requires extensive sampling grids covering several media including air, water, soil and vegetation. A far more efficient, innovative and inexpensive tactic has been found using honeybees as sampling mechanisms. Members from a single bee colony forage over large areas ({approx}2 x 10{sup 6} m{sup 2}), making tens of thousands of trips per day, and return to a fixed location where sampling can be conveniently conducted. The bees are in direct contact with the air, water, soil and vegetation where they encounter and collect any contaminants that are present in gaseous, liquid and particulate form. The monitoring of honeybees when they return to the hive provides a rapid method to assess chemical distributions and impacts (1). The primary goal of this technology is to evaluate the efficiency of the transport mechanism (honeybees) to the hive using preconcentrators to collect samples. Once the extent and nature of the contaminant exposure has been characterized, resources can be distributed and environmental monitoring designs efficiently directed to the most appropriate locations. Methyl salicylate, a chemical agent surrogate was used as the target compound in this study.

  4. Headspace versus direct immersion solid phase microextraction in complex matrixes: investigation of analyte behavior in multicomponent mixtures.

    Science.gov (United States)

    Gionfriddo, Emanuela; Souza-Silva, Érica A; Pawliszyn, Janusz

    2015-08-18

    This work aims to investigate the behavior of analytes in complex mixtures and matrixes with the use of solid-phase microextraction (SPME). Various factors that influence analyte uptake such as coating chemistry, extraction mode, the physicochemical properties of analytes, and matrix complexity were considered. At first, an aqueous system containing analytes bearing different hydrophobicities, molecular weights, and chemical functionalities was investigated by using commercially available liquid and solid porous coatings. The differences in the mass transfer mechanisms resulted in a more pronounced occurrence of coating saturation in headspace mode. Contrariwise, direct immersion extraction minimizes the occurrence of artifacts related to coating saturation and provides enhanced extraction of polar compounds. In addition, matrix-compatible PDMS-modified solid coatings, characterized by a new morphology that avoids coating fouling, were compared to their nonmodified analogues. The obtained results indicate that PDMS-modified coatings reduce artifacts associated with coating saturation, even in headspace mode. This factor, coupled to their matrix compatibility, make the use of direct SPME very practical as a quantification approach and the best choice for metabolomics studies where wide coverage is intended. To further understand the influence on analyte uptake on a system where additional interactions occur due to matrix components, ex vivo and in vivo sampling conditions were simulated using a starch matrix model, with the aim of mimicking plant-derived materials. Our results corroborate the fact that matrix handling can affect analyte/matrix equilibria, with consequent release of high concentrations of previously bound hydrophobic compounds, potentially leading to coating saturation. Direct immersion SPME limited the occurrence of the artifacts, which confirms the suitability of SPME for in vivo applications. These findings shed light into the implementation of in

  5. Modelling of adsorption kinetics and calibration curves of gaseous volatile organic compounds with adsorptive solid-phase microextraction fibre: toluene and acetone for indoor air applications.

    Science.gov (United States)

    Mocho, Pierre; Nicolle, Jérôme; Desauziers, Valérie

    2008-09-01

    Solid-phase microextraction (SPME) with adsorptive Carboxen/PDMS fibre is a powerful sampling device for volatile organic compounds (VOCs) at trace levels in air. However, owing to competitive adsorption, quantification remains a challenging task. In this area, a theoretical model, based on Fick's laws and an extended Langmuir equation, is proposed to deal with the adsorption kinetics of acetone/toluene mixture on SPME fibre under various static extraction conditions. The semipredictive model is first used to determine the axial diffusion coefficients of analytes in the sampling device. The model is then tested with a complex VOC mixture, showing good agreement with experimental data.

  6. Solid phase syntheses of oligoureas

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, K.; Linthicum, D.S.; Russell, D.H.; Shin, H.; Shitangkoon, A.; Totani, R.; Zhang, A.J.; Ibarzo, J. [Texas A& M Univ., College Station, TX (United States)

    1997-02-19

    Isocyanates 7 were formed from monoprotected diamines 3 or 6, which in turn can be easily prepared from commercially available N-BOC- or N-FMOC-protected amino acid derivatives. Isocyanates 7, formed in situ, could be coupled directly to a solid support functionalized with amine groups or to amino acids anchored on resins using CH{sub 2}Cl{sub 2} as solvent and an 11 h coupling time at 25 {degree}C. Such couplings afforded peptidomimetics with an N-phthaloyl group at the N-terminus. The optimal conditions identified for removal of the N-phthaloyl group were to use 60% hydrazine in DMF for 1-3 h. Several sequences of amino acids coupled to ureas (`peptidic ureas`) and of sequential urea units (`oligoureas`) were prepared via solid phase syntheses and isolated by HPLC. Partition coefficients were measured for two of these peptidomimetics, and their water solubilities were found to be similar to the corresponding peptides. A small library of 160 analogues of the YGGFL-amide sequence was prepared via Houghten`s tea bag methodology. This library was tested for binding to the anti-{beta}-endorphin monoclonal antibody. Overall, this paper describes methodology for solid phase syntheses of oligourea derivatives with side chains corresponding to some of the protein amino acids. The chemistry involved is ideal for high-throughput syntheses and screening operations. 51 refs., 3 figs., 2 tabs.

  7. Quantitative and enantioselective analysis of monoterpenes from plant chambers and in ambient air using SPME

    Science.gov (United States)

    Yassaa, N.; Custer, T.; Song, W.; Pech, F.; Kesselmeier, J.; Williams, J.

    2010-11-01

    A headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) system has been developed for quantifying enantiomeric and nonenantiomeric monoterpenes in plant chamber studies and ambient air. Performance of this system was checked using a capillary diffusion system to produce monoterpene standards. The adsorption efficiency, competitive adsorption and chromatographic peak resolution of monoterpene enantiomer pairs were compared for three SPME fibre coatings: 75 μm Carboxen-PDMS (CAR-PDMS), 50/30 μm divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) and 65 μm divinylbenzene-polydimethylsiloxane (DVB-PDMS). Key parameters such as the linearity and reproducibility of the SPME system have been investigated in this work. The best compromise between the enantiomeric separation of monoterpenes and competitive adsorption of the isoprenoids on the solid SPME fibre coating was found for DVB-PDMS fibres. The optimum conditions using DVB-PDMS fibres were applied to measure the exchange rates of monoterpenes in the emission of Quercus ilex using a laboratory whole plant enclosure under light and dark conditions, as well as in ambient air. With 592 and 223 ng m-2 s-1 respectively, β-myrcene and limonene were the predominant monoterpenes in the emission of Q. ilex. These values were closely comparable to those obtained using a zNose and cartridge GC-FID systems.

  8. Electrophoretic deposition of graphene oxide onto carbon fibers for in-tube solid-phase microextraction.

    Science.gov (United States)

    Feng, Juanjuan; Wang, Xiuqin; Tian, Yu; Bu, Yanan; Luo, Chuannan; Sun, Min

    2017-09-29

    Carbon fibers (CFs) were functionalized with graphene oxide (GO) by an electrophoretic deposition (EPD) method for in-tube solid-phase microextraction (SPME). GO-CFs were filled into a poly(ether ether ketone) (PEEK) tube to obtain a fibers-in-tube SPME device, which was connected with high performance liquid chromatography (HPLC) equipment to build online SPME-HPLC system. Compared with CFs, GO-CFs presented obviously better extraction performance, due to excellent adsorption property and large surface area of GO. Using ten polycyclic aromatic hydrocarbons (PAHs) as model analytes, the important extraction conditions were optimized, such as sample flow rate, extraction time, organic solvent content and desorption time. An online analysis method was established with wide linear range (0.01-50μgL -1 ) and low detection limits (0.001-0.004μgL -1 ). Good sensitivity resulted from high enrichment factors (1133-3840) of GO-CFs in-tube device towards PAHs. The analysis method was used to online determination of PAHs in wastewater samples. Some target analytes were detected and relative recoveries were in the range of 90.2-112%. It is obvious that the proposed GO-CFs in-tube device was an efficient extraction device, and EPD could be used to develop nanomaterials functionalized sorbents for sample preparation. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Metal-organic aerogel as a coating for solid-phase microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Saraji, Mohammad, E-mail: saraji@cc.iut.ac.ir; Shahvar, Ali

    2017-06-22

    An iron-based metal-organic aerogel was synthesized using metal-organic framework nanoparticles and applied as a fiber coating for solid-phase microextraction (SPME). Chemical, thermal and morphological characteristics of the material were investigated. Headspace SPME followed by gas chromatography-electron capture detection was used for the determination of chlorobenzenes in the environmental samples. The key experimental factors affecting the extraction efficiency of the analytes, such as ionic strength, extraction and desorption temperature, and extraction time were investigated and optimized. The applicability of the coating for the extraction of chlorobenzenes from the environmental samples including river and tap water, sludge, and coastal soil was evaluated. The detection limits were in the range of 0.1–60 ng L{sup −1}. The relative standard deviations were between 2.0 and 5.0%. The extraction recovery of the analytes was in the range of 88–100%. Compared to the commercial PDMS fiber, the present fiber showed better extraction efficiency. - Highlights: • Metal-organic aerogel was synthesized and used as a novel fiber coating for SPME. • The new coating material showed high surface area and good thermal stability. • GC-ECD was used for determination of chlorobenzenes in environmental samples. • The method showed fast extraction and better efficiency than PDMS commercial fiber.

  10. Identification of volatile compounds in soybean at various developmental stages using solid phase microextraction.

    Science.gov (United States)

    Boué, Stephen M; Shih, Betty Y; Carter-Wientjes, Carol H; Cleveland, Thomas E

    2003-08-13

    Soybean (Glycine max) seed volatiles were analyzed using a solid phase microextraction (SPME) method combined with gas chromatography-mass spectrometry (GC-MS). Thirty volatile compounds already reported for soybean were recovered, and an additional 19 compounds not previously reported were identified or tentatively identified. The SPME method was utilized to compare the volatile profile of soybean seed at three distinct stages of development. Most of the newly reported compounds in soybean seed were aldehydes and ketones. During early periods of development at maturity stage R6, several volatiles were present at relatively high concentrations, including 3-hexanone, (E)-2-hexenal, 1-hexanol, and 3-octanone. At maturity stage R7 and R8, decreased amounts of 3-hexanone, (E)-2-hexenal, 1-hexanol, and 3-octanone were observed. At maturity stage R8 hexanal, (E)-2-heptenal, (E)-2-octenal, ethanol, 1-hexanol, and 1-octen-3-ol were detected at relatively high concentrations. SPME offers the ability to differentiate between the three soybean developmental stages that yield both fundamental and practical information.

  11. Study of complex matrix effect on solid phase microextraction for biological sample analysis.

    Science.gov (United States)

    Jiang, Ruifen; Xu, Jianqiao; Zhu, Fang; Luan, Tiangang; Zeng, Feng; Shen, Yong; Ouyang, Gangfeng

    2015-09-11

    Solid phase microextraction (SPME) has become a useful tool for in vivo monitoring the behavior of environmental organic pollutants in biological species due to its simplicity, relatively non-invasive, and cost-effective manner. However, the complex matrices in biological samples could significantly influence the extraction kinetic, and bias the quantification result. In this study, we investigated the effect of complex matrix on the extraction kinetic of SPME for biological sample analysis. Two sample matrices, phosphate-buffered saline (PBS) with bovine serum albumin (BSA) and agarose gel with BSA were used to simulate the biological fluid and tissue. Results showed that the addition of BSA significantly enhanced the mass transfer of organic compounds onto SPME fiber in both PBS buffer and gel sample. Enhancement factors ranging from 1.3 to 27, and 2.0 to 80 were found for all selected polyaromatic hydrocarbons (PAHs) in PBS buffer and agarose gel with BSA concentration of 0.1-5%, respectively. Then, an improved theoretical model was applied to quantify the observed enhancement effect, and the result showed that the predicted sampling time constant agreed well with the experimental one in complex matrix. Furthermore, a simplified equation was proposed for the real biological sample analysis. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. SPME-GC analysis of THC in saliva samples collected with "EPITOPE" device.

    Science.gov (United States)

    Fucci, N; De Giovanni, N; Chiarotti, M; Scarlata, S

    2001-07-15

    In this study we examined the presence of cannabinoids in saliva samples obtained from 24 drug-abusers. The saliva specimens were collected by "EPITOPE" system and the subsequent elution of samples was achieved by centrifugation. The resulting ultrafiltrates have been directly sampled with solid phase micro-extraction (SPME) and then analyzed by GC/MS. Saliva sampling is less invasive than collection of blood.

  13. Predicting PAH bioaccumulation and toxicity in earthworms exposed to manufactured gas plant soils with solid-phase microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Michiel T.O. Jonker; Stephan A. van der Heijden; Joseph P. Kreitinger; Steven B. Hawthorne [Utrecht University, Utrecht (Netherlands). Institute for Risk Assessment Sciences

    2007-11-01

    Soils from former manufactured gas plant (MGP) sites are often heavily contaminated with polycyclic aromatic hydrocarbons (PAHs). Current risk assessment methods that rely on total PAH concentrations likely overstate adverse effects of such soils since bioavailability is ignored. In this study, solid-phase microextraction (SPME) was applied to estimate bioavailable PAH concentrations and toxicity in earthworms exposed to 15 MGP soils. In addition, PAH sorption to all soils (K{sub oc} values) was determined. The results showed a several orders of magnitude variation in K{sub oc} values, demonstrating that generic organic carbon-normalized sorption coefficients will typically be over-conservative at MGP sites. SPME-predicted bioaccumulation generally was within a factor of 10 of measured bioaccumulation (in earthworm bioassays), in contrast to current risk assessment model estimates that over predicted bioaccumulation 10-10,000 times. Furthermore, on the basis of estimated total body residues of narcotic PAHs, SPME correctly predicted worm mortality observed during bioassays in the majority of cases. For MGP sites where current risk assessment procedures indicate concerns, SPME thus provides a useful tool for performing a refined, site-specific assessment. 35 refs., 4 figs.

  14. Microwave-assisted headspace solid-phase microextraction for the analysis of bioemissions from Eucalyptus citriodora leaves.

    Science.gov (United States)

    Xiong, Guohua; Goodridge, Carolyn; Wang, Limei; Chen, Yong; Pawliszyn, Janusz

    2003-12-31

    Microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) was developed as a simple and effective method for fast sampling of volatile organic compounds (VOCs) from Eucalyptus citriodora Hook (E. citriodora) leaves. During microwave heating, a simple shielding device made of aluminum foil was used to protect the SPME fiber from microwave irradiation while allowing the sample to be heated. A room temperature water bath was also used to allow microwave heating to be conducted in a more controlled manner. The inner heating caused by microwave irradiation dramatically accelerated the emission of VOCs from the sample, but no marked change in headspace temperature in the sample vial was found. Under optimum conditions, the extraction efficiencies obtained with microwave heating were much higher than those obtained without microwave heating for all fibers used, namely, 7-microm polydimethylsiloxane (PDMS), 100-microm polydimethylsiloxane (PDMS), 65-microm polydimethylsiloxane/divinylbenzene (PDMS/DVB), and 75-microm carboxen/polydimethylsiloxane (CAR/PDMS). The improvement of extraction efficiency using MA-HS-SPME allowed more VOC events to be detected, with more balanced extraction of VOCs of lower and higher molecular masses. Moreover, a good linear relationship was found between sample size and GC-FID response (total peak area of VOCs), indicating the usefulness of MA-HS-SPME for quantitative analysis of individual volatile compounds in E. citriodora leaves.

  15. Fabrication of cross-linked hydrazone covalent organic frameworks by click chemistry and application to solid phase microextraction.

    Science.gov (United States)

    Wu, Mingxue; Chen, Gang; Ma, Jiutong; Liu, Ping; Jia, Qiong

    2016-12-01

    Covalent organic frameworks (COFs) are an emerging class of porous organic frameworks with diverse promising applications. Herein, we presented the first example of cross-linked hydrazone COFs (cross-linked COFs) coating via thiol-ene click chemistry for solid phase microextraction (SPME). Strong covalent bonds and interlayer of the prepared networks ensured the adsorption capacity and durability of the novel SPME fiber. π-π conjugated structure existed because of abundant phenyl rings and -C=N groups in the cross-lined COFs. A series of characterizations indicated that the cross-linked COFs possessed large surface areas, high porosities and stabilities as well as hydrophobicities. The fiber was applied to SPME of pesticide residues coupled with gas chromatography with an electron capture detector (GC-ECD). Under the optimum experimental conditions, enhancement factors in the range of 2190-10,998 were obtained, illustrating that the cross-linked COFs possessed remarkable preconcentration ability. The low detection limits of 0.0003-0.0023ngkg -1 were achieved with relative standard deviations (RSDs) in the range of 3.4-7.6% (intra-batch) and 5.7-11.6% (inter-batch), respectively. Recovery values in the range of 78.2-107.0% were obtained when the SPME-GC method was applied to the analysis of pesticides in cucumber samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Development of an in vitro thin-film solid-phase microextraction method to determine the bioavailability of xenoestrogens in soil.

    Science.gov (United States)

    Engler, Katherine Neafsey; Lemley, Ann T

    2013-09-01

    Biosolids applied to agricultural fields, parks, and other areas represent significant sources of estrogen-like endocrine disrupting compound (EEDC) inputs to soil. It is important to determine the bioavailability of EEDCs in soil to inform risk assessment concerning their environmental presence; Eisenia fetida (earthworms) are typically used in traditional in vivo bioavailability experiments. The development of an in vitro bioavailability method will decrease time, expense, and use of solvents in future analyses. A thin-film solid-phase microextraction (TF-SPME) method for determining the bioavailability of several EEDCs detected in biosolids was developed and optimized. It was found that the TF-SPME method could be used to calculate equilibrium porewater concentrations of diethylhexyl phthalate, bisphenol A, benzophenone, and triclosan at environmentally relevant concentrations in artificial soil within 88 min. The potential and limitations of using TF-SPME-generated porewater concentrations to predict E. fetida tissue concentrations are discussed. Copyright © 2013 SETAC.

  17. Determination of Xylene and Toluene by Solid-Phase Microextraction Using Au Nanoparticles-Thiol Silane Film Coupled to Ion Mobility Spectrometry.

    Science.gov (United States)

    Allafchian, Ali Reza; Akhgar, Ava; Ielbeigi, Vahideh; Tabrizchi, Mahmoud

    2016-11-01

    A simple, rapid and sensitive method for analysis of xylene and toluene was developed using the solid-phase microextraction (SPME) combined with ion mobilityspectrometry (IMS). Gold nanoparticles-thiol silane film (Au NPs-TSF) was applied as a newsorbent for SPME. Thiol silane film was formed on the surface of a stainless steel wire through incorporating Au nanoparticles during synthesis using sol-gel technique. The extraction properties of the fiber to xylene and toluene were examined, using a SPME device and thermal desorption ininjection port of IMS. The calibration graphs were linear in the range of 1.10-32.0 and 16.0-112.0 ppb for xylene and toluene, respectively. The detection limits for xylene and toluene were 0.7 and 8.0 ppb, respectively. The proposed method was applied without any considerable sample pretreatment and it was found to be simple enough to be strongly recommended for real sample analysis.

  18. Comparative analysis of the aroma chemicals of Melissa officinalis using hydrodistillation and HS-SPME techniques

    Directory of Open Access Journals (Sweden)

    Shakeel-u- Rehman

    2017-05-01

    Full Text Available Headspace solid-phase micro extraction (HS-SPME coupled with gas chromatography–mass spectrometry (GC–MS has been used for the chemical analysis of Melissa officinalis (leaves cultivated in Institute Germplasm. The HS-SPME analysis led to the identification of 22 components constituting 99.1% of the total volatile constituents present in the leaves whereas its hydrodistillate led to the identification of 24 volatile constituents constituting 98.1% of the volatile material. The chemical composition of the SPME and hydrodistilled extract of M. officinalis leaves comprised mainly of oxygenated monoterpenes (78.5% and 57.8% respectively and sesquiterpene hydrocarbons (14.9% and 29.7% respectively. The major components identified in the HS-SPME extract were citronellal (31.1%, citronellol (18.3%, β-caryophyllene (12.0%, (E-citral (11.9%, (Z-citral (9.6%, geraniol (3.6%, (Z-β-ocimene (3.1% and 1-octen-3-ol (2.0% whereas hydrodistilled essential oil was rich in (Z-citral (19.6%, β-caryophyllene (13.2%, (E-citral (11.2%, citronellal (10.2%, germacrene-d (8.3%, δ-3-carene (5.0%, 6-methyl-5-hepten-2-one (3.7% and citronellyl acetate (3.7%. The comparative analysis of volatile constituents of M. officinalis leaf extract using HS-SPME and hydrodistillation techniques shows both qualitative as well as quantitative differences. The current study is the first report involving rapid analysis of volatile components of M. officinalis by HS-SPME.

  19. Influence of fibre coating in headspace solid-phase microextraction-gas chromatographic analysis of aromatic and medicinal plants.

    Science.gov (United States)

    Bicchi, C; Drigo, S; Rubiolo, P

    2000-09-15

    Solid-phase microextraction (SPME) is a solvent-free technique, which is well established in headspace analysis since it is sensitive, because of the concentration factor achieved by the fibres, and selective, because of different coating materials which can be used. The performance of eight commercially available SPME fibres was compared to evaluate the recoveries of some characteristic components with different polarities and structures present in the headspace of four aromatic and medicinal plants: rosemary (Rosmarinus officinalis L.), sage (Salvia officinalis L.), thyme (Thymus vulgaris L.) and valerian (Valeriana officinalis L.). The relative concentration capacity of each fibre on the same components of each plant was also determined by comparing their abundance with that obtained by classical static-headspace GC. The partition coefficient, K1, between the headspace gaseous phase and SPME polymeric coating, and the relative concentration factors, of some of the characteristic components of the plant investigated dissolved in dibutyl phtalate, were also determined, under rigorously standardised analysis conditions. The results showed that the most effective fibres were those consisting of two components, i.e., a liquid phase (polydimethylsiloxane) and a porous solid (carboxen or divinylbenzene, or both).

  20. Glass bottle sampling solid phase microextraction gas chromatography mass spectrometry for breath analysis of drug metabolites.

    Science.gov (United States)

    Lu, Yan; Niu, Wenqi; Zou, Xue; Shen, Chengyin; Xia, Lei; Huang, Chaoqun; Wang, Hongzhi; Jiang, Haihe; Chu, Yannan

    2017-05-05

    Breath analysis is a non-invasive approach which may be applied to disease diagnosis and pharmacokinetic study. In the case of offline analysis, the exhaled gas needs to be collected and the sampling bag is often used as the storage vessel. However, the sampling bag usually releases some extra compounds, which may interfere with the result of the breath test. In this study, a novel breath sampling glass bottle was developed with a syringe needle sampling port for solid phase microextraction (SPME). Such a glass bottle scarcely liberates compounds and can be used to collect exhaled gas for ensuing analysis by gas chromatography-mass spectrometry (GC-MS). The glass bottle sampling SPME-GC-MS analysis was carried out to investigate the breath metabolites of myrtol, a multicompound drug normally used in the treatment of bronchitis and sinusitis. Four compounds, α-pinene, 2,3-dehydro-1,8-cineole, d-limonene and 1,8-cineole were found in the exhaled breath of all eight volunteers who had taken the myrtol. While for other ten subjects who had not used the myrtol, these compounds were undetectable. In the SPME-GC-MS analysis of the headspace of myrtol, three compounds were detected including α-pinene, d-limonene and 1,8-cineole. Comparing the results of breath and headspace analysis, it indicates that 2,3-dehydro-1,8-cineole in the breath is the metabolite of 1,8-cineole. It is the first time that this metabolite was identified in human breath. The study demonstrates that the glass bottle sampling SPME-GC-MS method is applicable to exhaled gas analysis including breath metabolites investigation of drugs like myrtol. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Estimation of bioavailability and potential risks of naphthalene in soils with solid phase microextraction.

    Science.gov (United States)

    Liu, Hsiang-Chao; Hwu, Ching-Shyung; Chu, Ko-Chiao; Lu, Chih-Jen

    2010-07-01

    A series of batch experiments were conducted to observe the variations of bioavailability of naphthalene in different types of soil with indigenous microorganisms. Solid phase microextraction (SPME) was employed to estimate the bioavailability of naphthalene in the soils. Various soil properties were attained by artificially modifying soil organic matter (SOM) with the addition of bagasse compost and textures with the addition of original silt and clay to determine the correlation between the amount of biodegraded naphthalene after 300 h and the amount of extractable naphthalene by SPME. Experimental results indicated that the biodegradation rate increased from 0.30 (sandy loam) to 0.48 (silty loam) μg g(-1) h(-1) when soils had more silt/clay. In contrast, the biodegradation rate slightly decreased from 0.30 (1.3% SOM) to 0.20 (5.2% SOM) μg g(-1) h(-1) when the SOM was high. Distributions of naphthalene in soils after biodegradation were affected by the addition of bagasse compost. It showed that the bioavailability of naphthalene in soils decreased with an increase in SOM. Sequestration as measured by ultrasonic extractability evidently occurred within 4 months in aged soil samples. However, the amounts extracted by sonication after 4 and 16 months of aging did not statistically differ from each other. The SPME measurements correlated well with the amount of biodegraded naphthalene by indigenous microorganisms. Results of this study demonstrate that SPME is a promising method to estimate the bioremediation efficacy of naphthalene-contaminated soils with various properties.

  2. Volatile phytochemical composition of rhizome of ginger after extraction by headspace solid-phase microextraction, petrol ether extraction and steam distillation extraction

    Directory of Open Access Journals (Sweden)

    Zhan-nan Yang

    2009-06-01

    Full Text Available The sampling techniques headspace solid-phase microextraction (HS-SPME, petrol ether extraction (PEE and steam distillation extraction (SDE were compared for the GC-MS of volatile constituents present in ginger (Zingiber officinale. The effects of different parameters, such as extraction fibers, extraction time, extraction temperature and particle size ranges, on the HSSPME of rhizome of ginger were investigated. Zingiberene (53.12% were predominant components of ginger samples obtained by HS-SPME whereas those levels were 39.01% in the same samples by PEE and 35.05% in those by SDE, respectively. HS-SPME with polydimethylsiloxane (PDMS fiber was more selective and particularly efficient for the isolation of volatile phytochemical composition and afforded a higher yield of total compounds than PEE and SDE. The specifically compound isolated by SPME, which due to effective fiber, was much larger than that isolated by PEE or SDE. HS-SPME is a powerful tool for determining the volatile constitutes present in the traditional Chinese medicines.

  3. Solid Phase Characterization of Solids Recovered from Failed Sluicer Arm

    Energy Technology Data Exchange (ETDEWEB)

    Cooke, Gary A. [Hanford Site (HNF), Richland, WA (United States)

    2015-03-09

    The Enclosure to this memo discusses the solid phase characterization of a solid sample that was retrieved from the single-shell Tank 241-C-111 extended reach sluicer #2. This sluicer, removed from riser #3 on September 25, 2014, was found to have approximately 0.4 gallons of solid tank waste adhering to the nozzle area.

  4. A two-component mass balance model for calibration of solid-phase microextraction fibers for pyrethroids in seawater.

    Science.gov (United States)

    Lao, Wenjian; Maruya, Keith A; Tsukada, David

    2012-11-06

    Determination of the analyte-specific distribution coefficient between the aqueous and sorbing phases is required for estimation of the aqueous-phase concentration of the analyte of interest using polymeric materials. Poly(dimethylsiloxane)-coated solid-phase microextration (PDMS-SPME) fiber-water partition coefficient (K(f)) values for eight common-use pyrethroids were determined using a two-compartment mass balance model and parameters determined in experimental seawater microcosms. Mass balance, epimerization, and aqueous-phase degradation (i.e., hydrolysis) were characterized using gas chromatography-negative chemical ionization mass spectrometry to facilitate K(f) estimation. Of the eight pyrethroids, only bifenthrin exhibited increasing sorption on the SPME fiber over the entire time-series exposure, indicating that its K(f) value could be estimated through a stable-compound model. The remaining pyrethroids were found to be unstable (half-life of 0.98) and the remaining unstable pyrethroids (R(2) > 0.7), leading to estimated values of log K(f) between 5.7 and 6.4, after correcting for residual dissolved organic carbon (DOC) in the experimental seawater. These K(f) values can be used to determine freely dissolved pyrethroid concentrations in the pg/L range using PDMS-SPME in fresh or seawater matrices under equilibrium conditions in laboratory or field applications.

  5. Sample preparation with solid phase microextraction and exhaustive extraction approaches: Comparison for challenging cases.

    Science.gov (United States)

    Boyacı, Ezel; Rodríguez-Lafuente, Ángel; Gorynski, Krzysztof; Mirnaghi, Fatemeh; Souza-Silva, Érica A; Hein, Dietmar; Pawliszyn, Janusz

    2015-05-11

    In chemical analysis, sample preparation is frequently considered the bottleneck of the entire analytical method. The success of the final method strongly depends on understanding the entire process of analysis of a particular type of analyte in a sample, namely: the physicochemical properties of the analytes (solubility, volatility, polarity etc.), the environmental conditions, and the matrix components of the sample. Various sample preparation strategies have been developed based on exhaustive or non-exhaustive extraction of analytes from matrices. Undoubtedly, amongst all sample preparation approaches, liquid extraction, including liquid-liquid (LLE) and solid phase extraction (SPE), are the most well-known, widely used, and commonly accepted methods by many international organizations and accredited laboratories. Both methods are well documented and there are many well defined procedures, which make them, at first sight, the methods of choice. However, many challenging tasks, such as complex matrix applications, on-site and in vivo applications, and determination of matrix-bound and free concentrations of analytes, are not easily attainable with these classical approaches for sample preparation. In the last two decades, the introduction of solid phase microextraction (SPME) has brought significant progress in the sample preparation area by facilitating on-site and in vivo applications, time weighted average (TWA) and instantaneous concentration determinations. Recently introduced matrix compatible coatings for SPME facilitate direct extraction from complex matrices and fill the gap in direct sampling from challenging matrices. Following introduction of SPME, numerous other microextraction approaches evolved to address limitations of the above mentioned techniques. There is not a single method that can be considered as a universal solution for sample preparation. This review aims to show the main advantages and limitations of the above mentioned sample

  6. Direct determination of anabolic steroids in pig urine by a new SPME-GC-MS method.

    Science.gov (United States)

    Zhang, Zhuomin; Duan, Hongbin; Zhang, Lan; Chen, Xi; Liu, Wei; Chen, Guonan

    2009-05-15

    A new solid phase microextraction (SPME) method coupled with gas chromatography-mass spectrometry (GC-MS) was developed for rapid determination of four anabolic steroids such as 3alpha-hydroxy-5alpha-androstane-17-one (HA), dihydrotestosterone (DHT), androstenedione (AD) and methyltestosterone (MT) in pig urine. SPME was used to extract the four anabolic compounds directly without derivatization. The optimum SPME sampling conditions were based on the home-made carbowax-divinylbenzene (CW-DVB) fiber coating during extraction at 40 degrees C for 50 min with 0.18 g/mL NaCl solution and 750 rpm stirring speed. The linear ranges of the proposed method were in the range of 8-640 pg/mL for HA and DHT and 16-510 pg/mL for AD and MT, respectively. The detection limits (S/N=3) were from 2 to 8 pg/mL for the four anabolic steroids. This SPME method provided very high enrichment factors for the four anabolic steroids, which were 1063-fold and 965-fold for HA and DHT at the concentration of 8 pg/mL and 207-fold and 451-fold for AD and MT at the concentration of 16 pg/mL, respectively. The recoveries ranged from 71.3 to 121%, and the RSDs were lower than 12.9%. The method was sensitive and reliable for determination of trace anabolic steroids in biological samples.

  7. A novel polythiophene – ionic liquid modified clay composite solid phase microextraction fiber: Preparation, characterization and application to pesticide analysis

    International Nuclear Information System (INIS)

    Pelit, Füsun Okçu; Pelit, Levent; Dizdaş, Tuğberk Nail; Aftafa, Can; Ertaş, Hasan; Yalçınkaya, E.E.; Türkmen, Hayati; Ertaş, F.N.

    2015-01-01

    Highlights: • A novel polythiophene – ionic liquid modified clay surface has been prepared. • Polymerization was performed electrochemically on a stainless steel wire. • This material was used as a SPME fiber in head space mode. • This new SPME fiber was applied for analysis of pesticides in juice samples. • Fiber adsorption properties were improved by modification of ionic liquids. - Abstract: This report comprises the novel usage of polythiophene – ionic liquid modified clay surfaces for solid phase microextraction (SPME) fiber production to improve the analysis of pesticides in fruit juice samples. Montmorillonite (Mmt) clay intercalated with ionic liquids (IL) was co-deposited with polythiophene (PTh) polymer coated electrochemically on an SPME fiber. The surface of the fibers were characterized by using scanning electron microscopy (SEM). Operational parameters effecting the extraction efficiency namely; the sample volume and pH, adsorption temperature and time, desorption temperature and time, stirring rate and salt amount were optimized. In order to reveal the major effects, these eight factors were selected and Plackett–Burman Design was constructed. The significant parameters detected; adsorption and temperature along with the stirring rate, were further investigated by Box–Behnken design. Under optimized conditions, calibration graphs were plotted and detection limits were calculated in the range of 0.002–0.667 ng mL −1 . Relative standard deviations were no higher than 18%. Overall results have indicated that this novel PTh-IL-Mmt SPME surface developed by the aid of electrochemical deposition could offer a selective and sensitive head space analysis for the selected pesticide residues

  8. A novel polythiophene – ionic liquid modified clay composite solid phase microextraction fiber: Preparation, characterization and application to pesticide analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pelit, Füsun Okçu, E-mail: fusun.okcu@ege.edu.tr; Pelit, Levent; Dizdaş, Tuğberk Nail; Aftafa, Can; Ertaş, Hasan; Yalçınkaya, E.E.; Türkmen, Hayati; Ertaş, F.N.

    2015-02-15

    Highlights: • A novel polythiophene – ionic liquid modified clay surface has been prepared. • Polymerization was performed electrochemically on a stainless steel wire. • This material was used as a SPME fiber in head space mode. • This new SPME fiber was applied for analysis of pesticides in juice samples. • Fiber adsorption properties were improved by modification of ionic liquids. - Abstract: This report comprises the novel usage of polythiophene – ionic liquid modified clay surfaces for solid phase microextraction (SPME) fiber production to improve the analysis of pesticides in fruit juice samples. Montmorillonite (Mmt) clay intercalated with ionic liquids (IL) was co-deposited with polythiophene (PTh) polymer coated electrochemically on an SPME fiber. The surface of the fibers were characterized by using scanning electron microscopy (SEM). Operational parameters effecting the extraction efficiency namely; the sample volume and pH, adsorption temperature and time, desorption temperature and time, stirring rate and salt amount were optimized. In order to reveal the major effects, these eight factors were selected and Plackett–Burman Design was constructed. The significant parameters detected; adsorption and temperature along with the stirring rate, were further investigated by Box–Behnken design. Under optimized conditions, calibration graphs were plotted and detection limits were calculated in the range of 0.002–0.667 ng mL{sup −1}. Relative standard deviations were no higher than 18%. Overall results have indicated that this novel PTh-IL-Mmt SPME surface developed by the aid of electrochemical deposition could offer a selective and sensitive head space analysis for the selected pesticide residues.

  9. Improvement of solid phase microextraction fiber assembly and interface for liquid chromatography.

    Science.gov (United States)

    Chen, Yong; Sidisky, Leonard M

    2012-09-19

    Modifications were made on commercial SPME fiber assembly and SPME-LC interface to improve the applicability of SPME for LC. Polyacrylonitrile (PAN)/C18 bonded fuse silica was used as the fiber coating for LC applications because the fiber coating was not swollen in common LC solvents at room temperature. The inner tubing of SPME fiber assembly was replaced with a 457 μm outside diameter (o.d.) solid nitinol rod. And the coated fiber (o.d. 290 μm) was installed onto the nitinol rod. The inner diameter (i.d.) of the through hole of the ferrule in the SPME-LC interface was enlarged to 508 μm to accommodate the nitinol rod. The much larger inner rod protected the fiber coating from being stripped when the fiber was withdrawn from the SPME-LC interface. The system was evaluated in term of pressure test, desorption optimization, peak shape, carryovers, linear range, precision, and limit of detection (LOD) with polycyclic aromatic hydrocarbons (PAHs) as the test analytes. The results demonstrated that the improved system was robust and reliable. It overcame the drawbacks, such as leak of solvents and damage of fiber coatings, associated with current SPME fibers and SPME-LC interface. Another sealing mechanism was proposed by sealing the nitinol rod with a specially designed poly(ether ether ketone) (PEEK) fitting. The device was fabricated and tested for manual use. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.

    2016-03-30

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid-phase extraction (MISPE) polymer. The polymers were functionalized on an interdigital capacitive sensor for selective binding of phthalate molecules from a complex mixture of chemicals. Both polymers owned predetermined selectivity by formation of valuable molecular recognition sites for Bis (2-ethylhexyl) phthalate (DEHP). Polymers were immobilized on planar electrochemical sensor fabricated on a single crystal silicon substrate with 500 nm sputtered gold electrodes fabricated using MEMS fabrication techniques. Impedance spectra were obtained using electrochemical impedance spectroscopy (EIS) to determine sample conductance for evaluation of phthalate concentration in the spiked sample solutions with various phthalate concentrations. Experimental results revealed that the ability of SPME polymer to adsorb target molecules on the sensing surface is better than that of MISPE polymer for phthalates in the sensing system. Testing the extracted samples using high performance liquid chromatography with photodiode array detectors validated the results.

  11. Chemically bonded carbon nanotubes on modified gold substrate as novel unbreakable solid phase microextraction fiber

    International Nuclear Information System (INIS)

    Bagheri, H.; Ayazi, Z.; Sistani, H.

    2011-01-01

    A new technique is introduced for preparation of an unbreakable fiber using gold wire as a substrate for solid phase microextraction (SPME). A gold wire is used as a solid support, onto which a first film is deposited that consists of a two-dimensional polymer obtained by hydrolysis of a self-assembled monolayer of 3-(trimethoxysilyl)-1-propanthiol. This first film is covered with a layer of 3-(triethoxysilyl)-propylamine. Next, a stationary phase of oxidized multi-walled carbon nanotubes was chemically bound to the surface. The synthetic strategy was verified by Fourier transform infrared spectroscopy and scanning electron microscopy. Thermal stability of new fiber was examined by thermogravimetric analysis. The applicability of the novel coating was verified by its employment as a SPME fiber for isolation of diazinon and fenthion, as model compounds. Parameters influencing the extraction process were optimized to result in limits of detection as low as 0.2 ng mL -1 for diazinon, and 0.3 ng mL -1 for fenthion using the time-scheduled selected ion monitoring mode. The method was successfully applied to real water, and the recoveries for spiked samples were 104% for diazinon and 97% for fenthion. (author)

  12. Quantification of 31 volatile organic compounds in whole blood using solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Blount, Benjamin C; Kobelski, Robert J; McElprang, David O; Ashley, David L; Morrow, John C; Chambers, David M; Cardinali, Frederick L

    2006-03-07

    The prevalence of exposure to volatile organic compounds (VOCs) has raised concern about possible health effects resulting from chronic human exposure. To support studies exploring the relation between VOC exposure and health effects, we developed an automated analytical method using solid-phase microextraction (SPME), capillary gas chromatography (GC), and quadrupole mass spectrometry (MS). This method quantifies trace levels (low parts per trillion) of 14 halogenated alkanes, 5 halogenated alkenes, 10 aromatic compounds, and 2 other VOCs in human blood. Detection limits for the SPME-GC-MS method range from 0.005 to 0.12 microg/L, with linear calibration curves spanning three orders of magnitude. The improved throughput of this method will enable us to expand biomonitoring efforts to assess nonoccupational VOC exposure in large epidemiological studies.

  13. Rapid analysis of malathion in blood using head space-solid phase microextraction and selected ion monitoring.

    Science.gov (United States)

    Namera, A; Yashiki, M; Nagasawa, N; Iwasaki, Y; Kojima, T

    1997-08-04

    A simple and rapid method for analysis of malathion in blood was developed using head space-solid phase microextraction (HS-SPME) and gas chromatography mass spectrometry/ electron impact ionization-selected ion monitoring (GC-MS/EI-SIM). A vial containing a blood sample, ammonium sulphate, sulphuric acid and fenitrothion as an internal standard, was heated at 90 degrees C for 15 min. The extraction fiber of the SPME was exposed for 5 min in the head space of the vial. The compounds absorbed on the fiber were detached by exposing the fibre in the injection port of GC-MS. A straight calibration curve was obtained between malathion concentrations of 2.5 to 50.0 micrograms g-1 in blood. No interfering substances were found, and the time for analysis was 40 min for one sample.

  14. Analysis of volatiles in dehydrated carrot samples by solid-phase microextraction followed by GC-MS.

    Science.gov (United States)

    Soria, Ana Cristina; Sanz, Jesús; Villamiel, Mar

    2008-10-01

    A solid-phase microextraction (SPME)-based method for the GC-MS analysis of volatiles in dehydrated carrot root samples has been developed and the effect of the most important factors (fibre coating, extraction temperature, equilibrium time and extraction time) on the fractionation of different volatiles has been studied. GC-MS chromatograms showed terpenoids relevant to carrot aroma such as alpha-pinene, sabinene, beta-myrcene, limonene, gamma-terpinene, terpinolene, trans-caryophyllene and beta-bisabolene, and several furan derivatives whose origin is discussed in this paper. As an example of application, this methodology has been used for the characterization of volatile composition of industrially dehydrated carrots. SPME followed by GC-MS is shown as an affordable, fast and solvent-free technique which can be performed with low sample amounts and be easily implemented at an industry for quality control purposes.

  15. Determination of 2,5-hexanedione in urine by headspace solid-phase microextraction and gas chromatography.

    Science.gov (United States)

    Oliveira, Antônio Felipe F; Maia, Patrícia P; Paiva, Maria José N; Siqueira, Maria Elisa P B

    2009-05-01

    2,5-Hexanedione (2,5-HD) is the most important metabolite of n-hexane and methyl ethyl ketone in human urine. Urinary 2,5-HD is used as a biomarker for biological monitoring of workers exposed to n-hexane. A simple method using headspace solid-phase microextraction (HS-SPME) and gas chromatography (GC) equipped with a flame-ionization detector (FID) was developed. The parameters that affect the HS-SPME-GC-FID process were optimized (i.e., fiber coating, sample volume, adsorption and heating time, salt addition, and extraction temperature). The assay presented linearity in the range of 0.075 to 20.0 mg/L, precision (coefficient of variation L for 2,5-HD in urine. The method was successfully applied to the analysis of 2,5-HD in urine samples from eight workers occupationally exposed to n-hexane in shoemaker's glue.

  16. Determination of some selected pesticide residues in apple juice by solid-phase microextraction coupled to gas chromatography – mass spectrometry

    Directory of Open Access Journals (Sweden)

    Andrea Hercegová

    2011-01-01

    Full Text Available The performance of solid phase microextraction (SPME for enrichment of pesticides from apple juice was investigated. Samples were diluted with water, extracted by solid-phase microextraction and analysed by gas chromatography using mass-spectrometry detector (MSD in selected ion monitoring mode (SIM. The method was tested for the following pesticides used mostly in fruit culturing at Slovakia: tebuthylazine, fenitrothion, chlorpyrifos, myclobutanil, cyprodinil, phosalone, pyrimethanil, tebuconazole, kresoxim-methyl, methidathion, penconazole. All pesticides were extracted with polydimethylsiloxane fibre 100 μm thickness. The linear concentration range of application was 0.05 μg dm−3–10 μg dm−3. The method described provides detectabilities complying with the maximum residue levels (MRLs set by regulatory organizations for pesticides in apple juice matrices. The solvent – free SPME procedure was found to be quicker and more cost effective then the solvent extraction methods commonly used.

  17. SPME as a promising tool in translational medicine and drug discovery: From bench to bedside.

    Science.gov (United States)

    Goryński, Krzysztof; Goryńska, Paulina; Górska, Agnieszka; Harężlak, Tomasz; Jaroch, Alina; Jaroch, Karol; Lendor, Sofia; Skobowiat, Cezary; Bojko, Barbara

    2016-10-25

    Solid phase microextraction (SPME) is a technology where a small amount of an extracting phase dispersed on a solid support is exposed to the sample for a well-defined period of time. The open-bed geometry and biocompatibility of the materials used for manufacturing of the devices makes it very convenient tool for direct extraction from complex biological matrices. The flexibility of the formats permits tailoring the method according the needs of the particular application. Number of studies concerning monitoring of drugs and their metabolites, analysis of metabolome of volatile as well as non-volatile compounds, determination of ligand-protein binding, permeability and compound toxicity was already reported. All these applications were performed in different matrices including biological fluids and tissues, cell cultures, and in living animals. The low invasiveness of in vivo SPME, ability of using very small sample volumes and analysis of cell cultures permits to address the rule of 3R, which is currently acknowledged ethical standard in R&D labs. In the current review systematic evaluation of the applicability of SPME to studies required to be conduct at different stages of drug discovery and development and translational medicine is presented. The advantages and challenges are discussed based on the examples directly showing given experimental design or on the studies, which could be translated to the models routinely used in drug development process. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Multiple headspace-solid-phase microextraction: an application to quantification of mushroom volatiles.

    Science.gov (United States)

    Costa, Rosaria; Tedone, Laura; De Grazia, Selenia; Dugo, Paola; Mondello, Luigi

    2013-04-03

    Multiple headspace-solid phase microextraction (MHS-SPME) followed by gas chromatography/mass spectrometry (GC-MS) and flame ionization detection (GC-FID) was applied to the identification and quantification of volatiles released by the mushroom Agaricus bisporus, also known as champignon. MHS-SPME allows to perform quantitative analysis of volatiles from solid matrices, free of matrix interferences. Samples analyzed were fresh mushrooms (chopped and homogenized) and mushroom-containing food dressings. 1-Octen-3-ol, 3-octanol, 3-octanone, 1-octen-3-one and benzaldehyde were common constituents of the samples analyzed. Method performance has been tested through the evaluation of limit of detection (LoD, range 0.033-0.078 ng), limit of quantification (LoQ, range 0.111-0.259 ng) and analyte recovery (92.3-108.5%). The results obtained showed quantitative differences among the samples, which can be attributed to critical factors, such as the degree of cell damage upon sample preparation, that are here discussed. Considerations on the mushrooms biochemistry and on the basic principles of MHS analysis are also presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Determination of amphetamine-type stimulants (ATSs) and synthetic cathinones in urine using solid phase micro-extraction fibre tips and gas chromatography-mass spectrometry

    OpenAIRE

    Alsenedi, Khalid A.; Morrison, Calum

    2018-01-01

    In recent years, an increasing number of stimulant drugs and new psychoactive substances (NPSs) have caused concern in scientific communities and therefore innovative methods to extract compounds from complex biological samples are required. This work is aimed at developing and validating a clean, convenient and straightforward extraction procedure with microliter amounts of organic solvent using Solid Phase Micro-Extraction tips (SPME tips) and analysis using Gas Chromatography-Mass Spectrom...

  20. Effect of Binding Components in Complex Sample Matrices on Recovery in Direct Immersion Solid-Phase Microextraction: Friends or Foe?

    Science.gov (United States)

    Alam, Md Nazmul; Pawliszyn, Janusz

    2018-02-20

    The development of matrix compatible coatings for solid-phase microextraction (SPME) has enabled direct extraction of analytes from complex sample matrices. The direct immersion (DI) mode of SPME when utilized in conjunction with such extraction phases facilitates extraction of a wide range of analytes from complex matrices without the incurrence of fouling or coating saturation. In this work, mathematical models and computational simulations were employed to investigate the effect of binding components present in complex samples on the recovery of small molecules varying in logP for extractions carried out using the direct immersion approach. The presented findings corroborate that the studied approach indeed enables the extraction of both polar and nonpolar analytes from complex matrices, provided a suitable sorbent is employed. Further results indicated that, in certain cases, the kinetics of extraction of a given analyte in its free form might be dependent on the desorption kinetics of their bound form from matrix components, which might lower total recoveries of analytes with high affinity for the matrix. However, the binding of analytes to matrix components also enables SPME to extract a balanced quantity of different logP analytes, facilitated by multiphase equilibria, with a single extraction device.

  1. Preparation of molecularly imprinted solid-phase microextraction fiber for the selective removal and extraction of the antiviral drug abacavir in environmental and biological matrices

    International Nuclear Information System (INIS)

    Terzopoulou, Zoi; Papageorgiou, Myrsini; Kyzas, George Z.; Bikiaris, Dimitrios N.; Lambropoulou, Dimitra A.

    2016-01-01

    In the present study, a molecularly imprinted solid-phase microextraction fiber (MIP-SPME f ) was synthesized and applied for the selective removal and extraction of the antiviral drug, abacavir (ABA). Morphology and structure characterization of fibers were performed by scanning electron microscopy and Fourier transform infrared spectra, respectively. The effects on the adsorption behavior of the process parameters were studied and the equilibrium data were fitted by the Langmuir, Freundlich and Langmuir-Freundlich models. The maximum adsorption capability (Q max ) was determined by Langmuir- Freundlich model and was 149 mg/g for MIP-SPME f . In the next step, SPME methodology followed by liquid desorption and liquid chromatography with mass spectrometry (LC/MS) has been developed and evaluated for the determination of the target compound in environmental and biological matrices (surface waters, wastewaters and urine). Parameters that could influence SPME efficiency were investigated. Then, optimization of stirring speed, extraction time and salt content was carried out by using a central composite design (CCD) and response surface methodology (RSM). A quadratic model between dependent and independent variables was built. Under the optimum conditions (extraction time 40 min, stirring rate 650 rpm and salt content 0.3% NaCl w/v) the validated method presented a high sensitivity and selectivity with LODs and LOQs in the range of 10.1–13.6 and 33.3–43.9 ng/L, respectively. The developed method was successfully applied to the analysis of ABA in real samples. The percentage extraction efficiency ranged from 88 to 99% revealing good accuracy and absence of matrix effects. - Highlights: • Preparation of a novel SPME MIP fiber with remarkable recognition properties. • Selective removal and extraction of abacavir from environmental & biological media. • Detailed adsorbent characterization and adsorption studies. • Successful application of synthesized MIPs

  2. Comparison of Ultrasound-Assisted Headspace Solid-Phase Microextraction and Hydrodistillation for the Identification of Major Constituents in Two Species of Hypericum.

    Science.gov (United States)

    Ghiasvand, Alireza; Shadabi, Shahriar; Hajipour, Somayeh; Nasirian, Afagh; Borzouei, Mohammad; Hassani-Moghadam, Esfandyar; Hashemi, Payman

    2016-02-01

    Ultrasound-assisted headspace solid-phase microextraction (UA-HS-SPME) and hydrodistillation (HD) methods, coupled to gas chromatography-mass spectrometry (GC-MS), were used for the extraction and analysis of volatile compounds from Hypericum perforatum and Hypericum scabrum collected from two different sites in Iran. In the UA-HS-SPME method, various experimental parameters such as the type of fiber coating, sonication time, extraction time, extraction temperature and desorption time were investigated. The highest extraction efficiency was achieved by a 100-µm polydimethylsiloxane (PDMS) fiber. Consequently, 36 compounds were identified in H. perforatum and H. scabrum samples, using the UA-HS-SPME-GC-MS method, of which 14 were the same in both species. On the other hand, 57 compounds of these species were identified by the HD-GC-MS method, of which 21 were the same. The predominant constituents identified using the UA-HS-SPME method in H. perforatum included β-caryophyllene, α-pinene, γ-cadinene, α-selinene, germacrene-D, limonene and myrcene, and in H. scabrum were α-pinene, nonane, β-pinene and limonene. The common constituents identified by the HD-GC-MS method for H. perforatum involved germacrene-D, limonene, β-caryophyllene, α-pinene, β-pinene and germacrene-B, and for H. scabrum were α-pinene, β-pinene, germacrene-D, nonane, limonene and γ-cadinene. The results about the main constituents of the examined species correspond to the findings of other researchers. Additionally, comparing UA-HS-SPME-GC-MS and HD-GC-MS methods showed that the UA-HS-SPME-GC-MS method is much faster and simpler, and it requires much less sample size and lower temperature. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

    Science.gov (United States)

    Spietelun, Agata; Marcinkowski, Łukasz; de la Guardia, Miguel; Namieśnik, Jacek

    2013-12-20

    Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including practical applications of these techniques and a critical discussion about their advantages and disadvantages. The proposed solutions fulfill the requirements resulting from the concept of sustainable development, and specifically from the implementation of green chemistry principles in analytical laboratories. Therefore, particular attention was paid to the description of possible uses of novel, selective stationary phases in extraction techniques, inter alia, polymeric ionic liquids, carbon nanotubes, and silica- and carbon-based sorbents. The methodological solutions, together with properly matched sampling devices for collecting analytes from samples with varying matrix composition, enable us to reduce the number of errors during the sample preparation prior to chromatographic analysis as well as to limit the negative impact of this analytical step on the natural environment and the health of laboratory employees. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Comparison of SPME Methods for Determining Volatile Compounds in Milk, Cheese, and Whey Powder

    Directory of Open Access Journals (Sweden)

    Michael H. Tunick

    2013-11-01

    Full Text Available Solid phase microextraction and gas chromatography-mass spectrometry (SPME-GC-MS are commonly used for qualitative and quantitative analysis of volatile compounds in various dairy products, but conditions have to be adjusted to maximize release while not generating new compounds that are absent in the original sample. Queso Fresco, a fresh non-melting cheese, may be heated at 60 °C for 30 min; in contrast, compounds are produced in milk when exposed to light and elevated temperatures, so milk samples are heated as little as possible. Products such as dehydrated whey protein are more stable and can be exposed to longer periods (60 min of warming at lower temperature (40 °C without decomposition, allowing for capture and analysis of many minor components. The techniques for determining the volatiles in dairy products by SPME and GC-MS have to be optimized to produce reliable results with minimal modifications and analysis times.

  5. Polyelectrolyte coatings prevent interferences from charged nanoparticles in SPME speciation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zielińska, Katarzyna, E-mail: kzielinska@gmail.com; Leeuwen, Herman P. van

    2014-09-24

    Highlights: • For the first time SPME fiber is coated with polyelectrolyte layer. • Sorption of nanoparticles on the solid phase surface is prevented. • Polyelectrolyte-modified fiber enables extraction of free analyte in presence of sorbing nanoparticles. - Abstract: In this work we present a new approach for protection of the fiber in solid phase microextraction (SPME) from interfering charged particles present in the sample medium. It involves coating of commercial poly(dimethylsiloxane) extraction phase with polyelectrolyte layer composed of poly(diallyldimethylammonium chloride), and poly(sodium 4-styrenesulfonate). The modified fiber provides reproducible, convenient and fast extraction capabilities toward the model analyte, triclosan (TCS). A negatively charged polyelectrolyte coating prevents sorbing oxidic nanoparticles from both partitioning into the PDMS phase and aggregation at its surface. The results for the TCS/nanoparticle sample show that the polyelectrolyte layer-modified solid phase extracts just the free form of the organic compound and enables dynamic speciation analysis of the nanoparticulate target analyte complex.

  6. Polyelectrolyte coatings prevent interferences from charged nanoparticles in SPME speciation analysis

    International Nuclear Information System (INIS)

    Zielińska, Katarzyna; Leeuwen, Herman P. van

    2014-01-01

    Highlights: • For the first time SPME fiber is coated with polyelectrolyte layer. • Sorption of nanoparticles on the solid phase surface is prevented. • Polyelectrolyte-modified fiber enables extraction of free analyte in presence of sorbing nanoparticles. - Abstract: In this work we present a new approach for protection of the fiber in solid phase microextraction (SPME) from interfering charged particles present in the sample medium. It involves coating of commercial poly(dimethylsiloxane) extraction phase with polyelectrolyte layer composed of poly(diallyldimethylammonium chloride), and poly(sodium 4-styrenesulfonate). The modified fiber provides reproducible, convenient and fast extraction capabilities toward the model analyte, triclosan (TCS). A negatively charged polyelectrolyte coating prevents sorbing oxidic nanoparticles from both partitioning into the PDMS phase and aggregation at its surface. The results for the TCS/nanoparticle sample show that the polyelectrolyte layer-modified solid phase extracts just the free form of the organic compound and enables dynamic speciation analysis of the nanoparticulate target analyte complex

  7. Determination of parathion in biological fluids by means of direct solid-phase microextraction.

    Science.gov (United States)

    Gallardo, E; Barroso, M; Margalho, C; Cruz, A; Vieira, D N; López-Rivadulla, M

    2006-11-01

    A new and simple procedure for the determination of parathion in human whole blood and urine using direct immersion (DI) solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. This technique was developed using only 100 microL of sample, and ethion was used as internal standard (IS). A 65-microm Carbowax/divinylbenzene (CW/DVB) SPME fibre was selected for sampling, and the main parameters affecting the SPME process such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH effect were optimized to enhance the sensitivity of the method. This optimization was also performed to allow the qualitative determination of parathion's main metabolite, paraoxon, in blood. The limits of detection and quantitation for parathion were 3 and 10 ng/mL for urine and 25 and 50 ng/mL for blood, respectively. For paraoxon, the limit of detection was 50 ng/mL in blood. The method showed linearity between the LOQ and 50 microg/mL for both matrices, with correlation coefficients ranging from 0.9954 to 0.9999. Precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries were 35.1% for urine and 6.7% for blood. Other parameters such as dilution of sample and stability were also validated. Its simplicity and the fact that only 100 microL of sample is required to accomplish the analysis make this method useful in forensic toxicology laboratories to determine this compound in intoxications, and it can be considered an alternative to other methods normally used for the determination of this compound in biological media.

  8. Evaluation of multiple solid-phase microextraction as a technique to remove the matrix effect in packaging analysis for determination of volatile organic compounds.

    Science.gov (United States)

    Ezquerro, Oscar; Pons, Begoña; Tena, María Teresa

    2003-12-12

    Multiple solid-phase microextraction (SPME) is an useful technique for the direct quantification of solid samples removing any matrix effect. The volatile organic compounds formed in the extrusion-coating process of multilayer packaging materials have already been quantified by multiple HS-SPME coupled to gas chromatography (GC)-mass spectrometry (MS) using volatile organic compound (VOC) solutions in hexadecane for calibration. In this article, water is proposed as solvent to prepare the calibration solutions because it provides a shorter calibration time, better linearity, better reproducibility, and lower detection limits than hexadecane. Besides, the extraction of VOCs from aqueous solutions is exhaustive and avoids the extrapolations needed to calculate the total peak areas, as they can be calculated as the sum of the individual areas of each extraction. Finally, it is checked whether the two solvents provide the same mean values for the total peak areas.

  9. Improving the Sensitivity of Solid-Phase Microextraction by Reducing the Volume of Off-Line Elution Solvent.

    Science.gov (United States)

    Xu, Jianqiao; Liu, Xiwen; Wang, Qi; Huang, Shuyao; Yin, Li; Xu, Jing; Liu, Xianguo; Jiang, Ruifen; Zhu, Fang; Ouyang, Gangfeng

    2018-02-06

    Solid-phase microextraction (SPME) coupled with liquid chromatograph (LC) is widely used to detect polar and ionic organic compounds, including various pharmaceuticals and endogenous bioactive compounds. In this study, a small-sized insert tube for use in the commercial autosampler vial was designed for eluting the extracted analytes from SPME fibers for LC analysis. By using this custom-made insert tube as an alternative to the commercial insert tube, the volume of the elution solvent was reduced by four-fifths. Even though smaller fractions of the analytes were eluted from the fiber coatings, the analyte concentrations in the elution solutions were substantially increased by using the custom-made insert tube. Therefore, larger amounts of the analytes could be injected to LC and higher signal-to-noise ratios could be achieved, even at smaller injection volumes. Since the elution in the custom-made insert tube was nonexhaustive, four strategies were developed to figure out the extracted amounts in the fiber coatings. In combination with the sampling-rate calibration method, these strategies were successfully used to determine the concentrations of fluoxetine in living tilapias. This study provides a simple but effect way for improving the analytical sensitivity when coupling SPME with LC.

  10. Rapid detection of five anesthetics in tilapias by in vivo solid phase microextraction coupling with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Huang, Shuyao; Xu, Jianqiao; Wu, Jiayi; Hong, Haojia; Chen, Guosheng; Jiang, Ruifen; Zhu, Fang; Liu, Yuan; Ouyang, Gangfeng

    2017-06-01

    The concentration of five rapidly metabolized anesthetics in living tilapias was determined in this study, by the presented method coupling in vivo solid phase microextraction (SPME) to gas chromatography-mass spectrometry (GC-MS), which was the first time that in vivo sampling method was adapted in detecting the anesthetic residue in the living aquatic product. The analytical performance of the developed method was evaluated in homogenized tilapia dorsal muscle, and the results demonstrated that the present method possessed low detection limits 1.7-9.4ngg -1 ), wide linear ranges (10 or 30-5000ngg -1 ), and satisfactory reproducibility (relative standard deviations no more than 8.1% and 10.8% for inter-fiber and intra-fiber assays, respectively). Standard curves were established in homogenized tilapia dorsal muscle for calibrating in vivo SPME in living tilapias. And the concentrations determined by in vivo SPME were close to those determined by the liquid extraction. By using the present method, one anesthetic residue was detected above the detection limit in tilapias from the local markets. Comparing to traditional methods, the present one exhibited superior time-efficiency and cost performance, as the extraction time was only ten minutes, which was short to successfully avoid the possible loss of analytes caused by elimination and sample storage. In addition, owing to the time-efficiency of the present method, the elimination of the anesthetics in tilapias was traced successfully in the laboratory. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Determination of benzene, toluene, ethylbenzene and xylenes in air by solid phase micro-extraction/gas chromatography/mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tumbiolo, Simonetta; Gal, Jean-Francois; Maria, Pierre-Charles [Universite de Nice-Sophia Antipolis, Laboratoire de Radiochimie, Sciences Analytiques et Environnement, Faculte des Sciences, Nice Cedex 2 (France); Zerbinati, Orfeo [Universita del Piemonte Orientale ' ' Amedeo Avogadro' ' , Dipartimento di Scienze e Tecnologie Avanzate, Alessandria (Italy)

    2004-11-01

    The aim of the study was to analyse BTEX compounds (benzene, toluene, ethylbenzene, xylenes) in air by solid phase micro-extraction/gas chromatography/mass spectrometry (SPME/GC/MS), and this article presents the features of the calibration method proposed. Examples of real-world air analysis are given. Standard gaseous mixtures of BTEX in air were generated by dynamic dilution. SPME sampling was carried out under non-equilibrium conditions using a Carboxen/PDMS fibre exposed for 30 min to standard gas mixtures or to ambient air. The behaviour of the analytical response was studied from 0 to 65 {mu}g/m{sup 3} by adding increasing amounts of BTEX to the air matrix. Detection limits range from 0.05 to 0.1 {mu}g/m{sup 3} for benzene, depending on the fibre. Inter-fibre relative standard deviations (reproducibility) are larger than 18%, although the repeatability for an individual fibre is better than 10%. Therefore, each fibre should be considered to be a particular sampling device, and characterised individually depending on the required accuracy. Sampling indoor and outdoor air by SPME appears to be a suitable short-delay diagnostic method for volatile organic compounds, taking advantage of short sampling time and simplicity. (orig.)

  12. Analysis of ammonium nitrate headspace by on-fiber solid phase microextraction derivatization with gas chromatography mass spectrometry.

    Science.gov (United States)

    Lubrano, Adam L; Andrews, Benjamin; Hammond, Mark; Collins, Greg E; Rose-Pehrsson, Susan

    2016-01-15

    A novel analytical method has been developed for the quantitation of trace levels of ammonia in the headspace of ammonium nitrate (AN) using derivatized solid phase microextraction (SPME) fibers with gas chromatography mass spectrometry (GC-MS). Ammonia is difficult to detect via direct injection into a GC-MS because of its low molecular weight and extreme polarity. To circumvent this issue, ammonia was derivatized directly onto a SPME fiber by the reaction of butyl chloroformate coated fibers with the ammonia to form butyl carbamate. A derivatized externally sampled internal standard (dESIS) method based upon the reactivity of diethylamine with unreacted butyl chloroformate on the SPME fiber to form butyl diethylcarbamate was established for the reproducible quantification of ammonia concentration. Both of these compounds are easily detectable and separable via GC-MS. The optimized method was then used to quantitate the vapor concentration of ammonia in the headspace of two commonly used improvised explosive device (IED) materials, ammonium nitrate fuel oil (ANFO) and ammonium nitrate aluminum powder (Ammonal), as well as identify the presence of additional fuel components within the headspace. Published by Elsevier B.V.

  13. Preparation by low-temperature nonthermal plasma of graphite fiber and its characteristics for solid-phase microextraction.

    Science.gov (United States)

    Luo, Fan; Wu, Zucheng; Tao, Ping; Cong, Yanqing

    2009-01-05

    Low-temperature nonthermal plasma has been used to prepare solid-phase microextraction (SPME) fibers with high adsorbability, long-term serviceability, and high reproducibility. Graphite rods serving as fiber precursors were treated by an air plasma discharged at 15.2-15.5 kV for a duration of 8 min. Sampling results revealed that the adsorptive capacity of the homemade fiber was 2.5-34.6 times that of a polyacrylate (PA) fiber for alcohols (methanol, ethanol, isopropyl alcohol, n-butyl alcohol), and about 1.4-1.6 times and 2.5-5.1 times that of an activated carbon fiber (ACF) for alcohols and BTEX (benzene, toluene, ethylbenzene, and xylenes), respectively. It is confirmed from FTIR (Fourier transform infrared spectrophotometer) and SEM (scanning electron microscope) analyses that the improvement in the adsorptive performance attributed to increased surface energy and roughness of the graphite fiber. Using gas chromatography (GC)-flame-ionization detector (FID), the limits of detection (LODs) of the alcohols and BTEX ranged between 0.19 and 3.75 microg L(-1), the linear ranges were between 0.6 and 35,619 microg L(-1) with good linearity (R(2)=0.9964-0.9997). It was demonstrated that nonthermal plasma offers a fast and simple method for preparing an efficient graphite SPME fiber, and that SPME using the homemade fiber represents a sensitive and selective extraction method for the analysis of a wide range of organic compounds.

  14. Preparation by low-temperature nonthermal plasma of graphite fiber and its characteristics for solid-phase microextraction

    International Nuclear Information System (INIS)

    Luo Fan; Wu Zucheng; Tao Ping; Cong Yanqing

    2009-01-01

    Low-temperature nonthermal plasma has been used to prepare solid-phase microextraction (SPME) fibers with high adsorbability, long-term serviceability, and high reproducibility. Graphite rods serving as fiber precursors were treated by an air plasma discharged at 15.2-15.5 kV for a duration of 8 min. Sampling results revealed that the adsorptive capacity of the homemade fiber was 2.5-34.6 times that of a polyacrylate (PA) fiber for alcohols (methanol, ethanol, isopropyl alcohol, n-butyl alcohol), and about 1.4-1.6 times and 2.5-5.1 times that of an activated carbon fiber (ACF) for alcohols and BTEX (benzene, toluene, ethylbenzene, and xylenes), respectively. It is confirmed from FTIR (Fourier transform infrared spectrophotometer) and SEM (scanning electron microscope) analyses that the improvement in the adsorptive performance attributed to increased surface energy and roughness of the graphite fiber. Using gas chromatography (GC)-flame-ionization detector (FID), the limits of detection (LODs) of the alcohols and BTEX ranged between 0.19 and 3.75 μg L -1 , the linear ranges were between 0.6 and 35619 μg L -1 with good linearity (R 2 = 0.9964-0.9997). It was demonstrated that nonthermal plasma offers a fast and simple method for preparing an efficient graphite SPME fiber, and that SPME using the homemade fiber represents a sensitive and selective extraction method for the analysis of a wide range of organic compounds

  15. Sodium hyaluronate-functionalized urea-formaldehyde monolithic column for hydrophilic in-tube solid-phase microextraction of melamine.

    Science.gov (United States)

    Wang, Jiabin; Jiang, Nan; Cai, Zhengmiao; Li, Wenbang; Li, Jianhua; Lin, Xucong; Xie, Zenghong; You, Lijun; Zhang, Qiqing

    2017-09-15

    A novel sodium hyaluronate-functionalized urea-formaldehyde (UF) monolithic column has been developed by in-situ polycondensation of urea, formaldehyde and sodium hyaluronate (HA). HA plays both the roles of crosslinking and hydrophilic functionalization. The preparation factors including different molecular weights of HA and different amounts of HA were optimized, and then a uniform monolith with satisfactory permeability and hydrophilic binding capacity was obtained. Due to the excellent hydrophilicity of HA, HA-functionalized UF monolith showed higher hydrophilic extraction efficiency than UF monolith, and was applied for hydrophilic in-tube solid-phase microextraction (SPME) of melamine (MEL). Several factors for hydrophilic in-tube SPME, such as ACN percentage in the sampling solution, salt concentration and pH value of the sampling solution, elution volume, sampling and elution flow rate, were investigated with respect to the extraction efficiency of MEL. Under the optimized SPME conditions, the limit of detection (LOD) of MEL was found to be 0.2ng/mL in the milk formula samples, the recoveries of MEL spiked in milk formula samples ranged from 87.3% to 96.7% with relative standard deviations (RSDs) less than 5.1%. Owing to the excellent hydrophilic extraction ability, the novel HA-functionalized UF monolith could provide a promising tool for the sensitive analysis of polar analytes in complicated samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Preparation and characterization of metal-organic framework MIL-101(Cr)-coated solid-phase microextraction fiber.

    Science.gov (United States)

    Xie, Lijun; Liu, Shuqin; Han, Zhubing; Jiang, Ruifen; Liu, Hong; Zhu, Fang; Zeng, Feng; Su, Chengyong; Ouyang, Gangfeng

    2015-01-01

    Metal-organic frameworks (MOFs) have received great attention as novel sorbents due to their fascinating structures and intriguing potential applications in various fields. In this work, a MIL-101(Cr)-coated solid-phase microextraction (SPME) fiber was fabricated by a simple direct coating method and applied to the determination of volatile compounds (BTEX, benzene, toluene, ethylbenzene, m-xylene and o-xylene) and semi-volatile compounds (PAHs, polycyclic aromatic hydrocarbons) from water samples. The extraction and desorption conditions of headspace SPME (HS-SPME) were optimized. Under the optimized conditions, the established methods exhibited excellent extraction performance. Good precision (<7.7%) and low detection limits (0.32-1.7 ng L(-1) and 0.12-2.1 ng L(-1) for BTEX and PAHs, respectively) were achieved. In addition, the MIL-101(Cr)-coated fiber possessed good thermal stability, and the fiber can be reused over 150 times. The fiber was successfully applied to the analysis of BTEX and PAHs in river water by coupling with gas chromatography-mass spectrometry (GC-MS). The analytes at low concentrations (1.7 and 10 ng L(-1)) were detected, and the recoveries obtained with the spiked river water samples were in the range of 80.0-113% and 84.8-106% for BTEX and PAHs, respectively, which demonstrated the applicability of the self-made fiber. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Novel polystyrene/antibody nanoparticle-coated capillary for immunoaffinity in-tube solid-phase microextraction.

    Science.gov (United States)

    Xu, Bei; Cheng, Shuai; Wang, Xianhua; Wang, Dongmei; Xu, Liang

    2015-04-01

    Antibody-coated polystyrene (PS) nanoparticles (denoted as PS/IgG) were prepared and chemically immobilized for the first time onto a capillary inner wall for immunoaffinity in-tube solid-phase microextraction (SPME) of β2-microglobin (β2MG) and cystatin C (Cys-C). Scanning electron microscopy images of the prepared capillary showed that the nanoparticles were evenly coated onto the capillary inner surface, resulting in the undulating surface of the capillary inner wall. The extraction capacity of the nanoparticle-coated capillary was nearly five times higher than that of a monolayer antibody-immobilized capillary. The in-tube SPME recovery of β2MG (or Cys-C) by the nanoparticle-functionalized capillary was more than 97.8%, whereas that by the monolayer antibody-immobilized tube was 30.5%. In addition, the method quantitation limit obtained by using the nanoparticle-coated capillary was ten times lower than that by the monolayer capillary. Therefore, the capillary coated by PS/IgG nanoparticles is more suitable for immunoaffinity in-tube SPME compared with the commonly used monolayer antibody-immobilized capillary.

  18. Solid-phase microextraction of methadone in urine samples by electrochemically co-deposited sol-gel/Cu nanocomposite fiber.

    Science.gov (United States)

    Mohammadiazar, Sirwan; Hasanli, Fateme; Maham, Mehdi; Payami Samarin, Somayeh

    2017-08-01

    Electrochemically co-deposited sol-gel/Cu nanocomposites have been introduced as a novel, simple and single-step technique for preparation of solid-phase microextraction (SPME) coating to extract methadone (MDN) (a synthetic opioid) in urine samples. The porous surface structure of the sol-gel/Cu nanocomposite coating was revealed by scanning electron microscopy. Direct immersion SPME followed by HPLC-UV determination was employed. The factors influencing the SPME procedure, such as the salt content, desorption solvent type, pH and equilibration time, were optimized. The best conditions were obtained with no salt content, acetonitrile as desorption solvent type, pH 9 and 10 min equilibration time. The calibration graphs for urine samples showed good linearity. The detection limit was about 0.2 ng mL -1 . Also, the novel method for preparation of nanocomposite fiber was compared with previously reported techniques for MDN determination. The results show that the novel nanocomposite fiber has relatively high extraction efficiency. Copyright © 2016 John Wiley & Sons, Ltd.

  19. Analysis of Volatile Components of Adenosma indianum (Lour. Merr. by Steam Distillation and Headspace Solid-Phase Microextraction

    Directory of Open Access Journals (Sweden)

    Zhi Zeng

    2013-01-01

    Full Text Available The essential oil of Adenosma indianum (Lour. Merr. plays an important role in its antibacterial and antiphlogistic activities. In this work, the volatile components were extracted by steam distillation (SD and headspace solid-phase microextraction (HS-SPME and analysed by gas chromatography-mass spectrometry (GC-MS. A total of 49 volatile components were identified by GC-MS, and the major volatile components were α-limonene (20.59–35.07%, fenchone (15.79–31.81%, α-caryophyllene (6.98–10.32%, β-caryophyllene (6.98–10.19%, and piperitenone oxide (1.96–11.63%. The comparison of the volatile components from A. indianum (Lour. Merr. grown in two regions of China was reported. Also, the comparison of the volatile components by SD and HS-SPME was discussed. The results showed that the major volatile components of A. indianum (Lour. Merr. from two regions of China were similar but varied with different extraction methods. These results were indicative of the suitability of HS-SPME method for simple, rapid, and solvent-free analysis of the volatile components of the medicinal plants.

  20. Headspace-solid phase microextraction approach for dimethylsulphoniopropionate quantification in Solanum lycopersicum plants subjected to water stress

    Directory of Open Access Journals (Sweden)

    Stefano Catola

    2016-08-01

    Full Text Available Dimethylsulphoniopropionate (DMSP and dimethyl sulphide (DMS are compounds found mainly in marine phytoplankton and in some halophytic plants. DMS is a globally important biogenic volatile in regulating of global sulphur cycle and planetary albedo, whereas DMSP is involved in the maintenance of plant-environment homeostasis. Plants emit minute amounts of DMS compared to marine phytoplankton and there is a need for hypersensitive analytic techniques to enable its quantification in plants. Solid Phase Micro Extraction from Head Space (HS-SPME is a simple, rapid, solvent-free and cost-effective extraction mode, which can be easily hyphenated with GC-MS for the analysis of volatile organic compounds (VOCs. Using tomato (Solanum lycopersicum plants subjected to water stress as a model system, we standardized a sensitive and accurate protocol for detecting and quantifying DMSP pool sizes, and potential DMS emissions, in cryoextracted leaves. The method relies on the determination of DMS free and from DMSP pools before and after the alkaline hydrolysis via HS-SPME-GC-MS. We found a significant (2.5 time increase of DMSP content in water-stressed leaves reflecting clear stress to the photosynthetic apparatus. We hypothesize that increased DMSP, and in turn DMS, in water-stressed leaves are produced by carbon sources other than direct photosynthesis, and function to protect plants either osmotically or as antioxidants. Finally, our results suggest that SPME is a powerful and suitable technique for the detection and quantification of biogenic gases in trace amounts.

  1. Solid phase microextraction, sand flies, oviposition pheromones, plaster of Paris and siloxanes-What is in common?

    Science.gov (United States)

    Goulart, Thais Marchi; Tosta, Christiann Davis; Machado, Vicente Estevam; da Rocha Silva, Flávia Benini; de Castro, Camila Feitosa; Ortiz, Dennys Ghenry Samillan; Oliveira, Wanderson Henrique Cruz; Pinto, Mara Cristina

    2017-04-01

    Sand flies are natural hosts of various microorganisms. Due to their epidemiological importance, sand fly colonies are kept in laboratories to be studied in terms of their biology and vector/host/parasite interactions. In order to investigate the presence of oviposition pheromones in Nyssomyia neivai, experiments using Solid Phase Microextraction (SPME) were performed. However, siloxanes which is an external class of contamination, present in breeding containers made by plaster used to maintain sand flies in colonies, may be hindered the experiments. Published by Elsevier B.V.

  2. Time-weighted average sampling of airborne propylene glycol ethers by a solid-phase microextraction device.

    Science.gov (United States)

    Shih, H C; Tsai, S W; Kuo, C H

    2012-01-01

    A solid-phase microextraction (SPME) device was used as a diffusive sampler for airborne propylene glycol ethers (PGEs), including propylene glycol monomethyl ether (PGME), propylene glycol monomethyl ether acetate (PGMEA), and dipropylene glycol monomethyl ether (DPGME). Carboxen-polydimethylsiloxane (CAR/PDMS) SPME fiber was selected for this study. A polytetrafluoroethylene (PTFE) tubing was used as the holder, and the SPME fiber assembly was inserted into the tubing as a diffusive sampler. The diffusion path length and area of the sampler were 0.3 cm and 0.00086 cm(2), respectively. The theoretical sampling constants at 30°C and 1 atm for PGME, PGMEA, and DPGME were 1.50 × 10(-2), 1.23 × 10(-2) and 1.14 × 10(-2) cm(3) min(-1), respectively. For evaluations, known concentrations of PGEs around the threshold limit values/time-weighted average with specific relative humidities (10% and 80%) were generated both by the air bag method and the dynamic generation system, while 15, 30, 60, 120, and 240 min were selected as the time periods for vapor exposures. Comparisons of the SPME diffusive sampling method to Occupational Safety and Health Administration (OSHA) organic Method 99 were performed side-by-side in an exposure chamber at 30°C for PGME. A gas chromatography/flame ionization detector (GC/FID) was used for sample analysis. The experimental sampling constants of the sampler at 30°C were (6.93 ± 0.12) × 10(-1), (4.72 ± 0.03) × 10(-1), and (3.29 ± 0.20) × 10(-1) cm(3) min(-1) for PGME, PGMEA, and DPGME, respectively. The adsorption of chemicals on the stainless steel needle of the SPME fiber was suspected to be one of the reasons why significant differences between theoretical and experimental sampling rates were observed. Correlations between the results for PGME from both SPME device and OSHA organic Method 99 were linear (r = 0.9984) and consistent (slope = 0.97 ± 0.03). Face velocity (0-0.18 m/s) also proved to have no effects on the sampler

  3. Novel metal-ion-mediated, complex-imprinted solid-phase microextraction fiber for the selective recognition of thiabendazole in citrus and soil samples.

    Science.gov (United States)

    Lian, Haixian; Hu, Yuling; Li, Gongke

    2014-01-01

    A novel metal-ion-mediated complex-imprinted-polymer-coated solid-phase microextraction (SPME) fiber used to specifically recognize thiabendazole (TBZ) in citrus and soil samples was developed. The complex-imprinted polymer was introduced as a novel SPME coating using a "complex template" constructed with Cu(II) ions and TBZ. The recognition and enrichment properties of the coating in water were significantly improved based on the metal ion coordination interaction rather than relying on hydrogen bonding interactions that are commonly applied for the molecularly imprinting technique. Several parameters controlling the extraction performance of the complex-imprinted-polymer-coated fiber were investigated including extraction solvent, pH value, extraction time, metal ion species, etc. Furthermore, SPME coupled with HPLC was developed for detection of TBZ, and the methods resulted in good linearity in the range of 10.0-150.0 ng/mL with a detection limit of 2.4 ng/mL. The proposed method was applied to the analysis of TBZ in spiked soil, orange, and lemon with recoveries of 80.0-86.9% and RSDs of 2.0-8.1%. This research provides an example to prepare a desirable water-compatible and specifically selective SPME coating to extract target molecules from aqueous samples by introducing metal ions as the mediator. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Studying Plant–Insect Interactions with Solid Phase Microextraction: Screening for Airborne Volatile Emissions Response of Soybeans to the Soybean Aphid, Aphis glycines Matsumura (Hemiptera: Aphididae

    Directory of Open Access Journals (Sweden)

    Lingshuang Cai

    2015-05-01

    Full Text Available Insects trigger plants to release volatile compounds that mediate the interaction with both pest and beneficial insects. Soybean aphids (Aphis glycines induces soybean (Glycine max leaves to produce volatiles that attract predators of the aphid. In this research, we describe the use of solid-phase microextraction (SPME for extraction of volatiles from A. glycines-infested plant. Objectives were to (1 determine if SPME can be used to collect soybean plant volatiles and to (2 use headspace SPME-GC-MS approach to screen compounds associated with A. glycines-infested soybeans, grown in the laboratory and in the field, to identify previously known and potentially novel chemical markers of infestation. A total of 62 plant volatiles were identified, representing 10 chemical classes. 39 compounds had not been found in previous studies of soybean volatile emissions. 3-hexen-1-ol, dimethyl nonatriene, indole, caryophyllene, benzaldehyde, linalool, methyl salicylate (MeSA, benzene ethanol, and farnesene were considered herbivore-induced plant volatiles (HIPVs. For reproductive field-grown soybeans, three compounds were emitted in greater abundance from leaves infested with A. glycines, cis-3-hexen-1-ol acetate, MeSA and farnesene. In summary, SPME can detect the emission of HIPVs from plants infested with insect herbivores.

  5. CODEX-compliant eleven organophosphorus pesticides screening in multiple commodities using headspace-solid phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Sang, Zi-Ye; Wang, Yu-Ting; Tsoi, Yeuk-Ki; Leung, Kelvin Sze-Yin

    2013-01-15

    A headspace-solid phase microextraction-gas chromatography-mass spectrometric (HS-SPME-GC-MS, hereafter abbreviated as "SPME") method was developed for dedicated organophosphorus (OP) pesticides assessment in multiple vegetable and fruit commodities. Specific extraction variables were optimised to achieve harmonised extraction performance of eleven OPs in a great span of seven characteristic commodities cataloged in Codex Alimentarius Commission. Comprehensive validation study confirmed analytical robustness of the SPME treatment in turnip, green cabbage, French beans, eggplant, apple, nectarine and grapes. Based on range-specific evaluation, extraction of individual OPs was characterised by sub-ppb level sensitivity and a wide 0.01-2.5 mg L(-1) dynamic range. Effective sample clean-up afforded precise quantification (0.5-10.9% R.S.D.) within a 70-120% recovery range at the MRL levels specified for individual commodities. Compared to conventional methods currently used, the SPME treatment developed here is quick, accurate, and relatively environmental friendly; it represents an attractive, practical way to deliver international standards in OP screening routines. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Solid-phase microextraction may catalize hydrogenation when using hydrogen as carrier in gas chromatography.

    Science.gov (United States)

    Fiorini, D; Boarelli, M C

    2016-07-01

    When hydrogen is used as carrier gas, carbon-carbon double bonds may be hydrogenated in the hot gas chromatograph (GC) injector if introduced by solid-phase microextraction (SPME). SPME fibers coated with polydimethylsiloxane (PDMS)/carboxen/divinylbenzene (DVB), PDMS/carboxen, polyacrylate, PDMS/DVB and PDMS on fused silica, stableflex or metal alloy core have been tested with fatty acid methyl esters (FAMEs) from olive oil. Using coatings containing DVB, hydrogenation took place with high conversion rates (82.0-92.9%) independently of the core material. With all fibers having a metal core, hydrogenation was observed to a certain extent (27.4-85.3%). PDMS, PDMS/carboxen and polyacrylate coated fibers with a fused silica or stableflex core resulted in negligible hydrogenation (0.2-2.5%). The occurrence of hydrogenation was confirmed also with other substances containing carbon-carbon double bonds (n-alkenes, alkenoic acids, mono- and polyunsaturated fatty acid methyl and ethyl esters). Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Determination of diphenylether herbicides in water samples by solid-phase microextraction coupled to liquid chromatography.

    Science.gov (United States)

    Sheu, Hong-Li; Sung, Yu-Hsiang; Melwanki, Mahaveer B; Huang, Shang-Da

    2006-11-01

    Solid-phase microextraction (SPME) coupled to LC for the analysis of five diphenylether herbicides (aclonifen, bifenox, fluoroglycofen-ethyl, oxyfluorfen, and lactofen) is described. Various parameters of extraction of analytes onto the fiber (such as type of fiber, extraction time and temperature, pH, impact of salt and organic solute) and desorption from the fiber in the desorption chamber prior to separation (such as type and composition of desorption solvent, desorption mode, soaking time, and flush-out time) were studied and optimized. Four commercially available SPME fibers were studied. PDMS/divinylbenzene (PDMS/DVB, 60 microm) and carbowax/ templated resin (CW/TPR, 50 microm) fibers were selected due to better extraction efficiencies. Repeatability (RSD, 0.994), and detection limit (0.33-1.74 and 0.22-1.94 ng/mL, respectively, for PDMS/DVB and CW/TPR) were investigated. Relative recovery (81-104% for PDMS/DVB and 83-100% for CW/TPR fiber) values have also been calculated. The developed method was successfully applied to the analysis of river water and water collected from a vegetable garden.

  8. Solid-phase microextraction of volatile compounds from the chopped leaves of three species of Eucalyptus.

    Science.gov (United States)

    Zini, Cláudia A; Zanin, Kelen D; Christensen, Eva; Caramão, Elina B; Pawliszyn, Janusz

    2003-04-23

    Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography and ion-trap mass spectrometry has been used to identify biogenic volatile organic compounds present in the headspace of chopped leaves of Eucalyptus (E.) dunnii, E. citriodora, and E. saligna. A simple HS-SPME method entailing 30 min of extraction at 30 degrees C was developed for this purpose. Thirty compounds were identified in the headspace of 60 juvenile chopped Eucalyptus leaves, and another 30 were tentatively identified. The presence of compounds such as (E)-4,8-dimethyl-1,3,7-nonatriene (DMNT), (E,E)-4,8,12-trimethyl-1,3,7,11-tridecatetraene (TMNT), (E,E)-alpha-farnesene, (E,E,E)-3,7,11,15-tetramethyl-1,3,6,10,14-hexadecapentaene (TMHP), beta-caryophyllene, alpha-humulene, germacrene D, and beta-cubebene in the headspace of the leaves but not in the essential oils from the same Eucalyptus trees and information about the infochemical roles of some of these compounds in other living plant systems suggest they might play a bioactive role in Eucalyptus leaves.

  9. Knitting aromatic polymers for efficient solid-phase microextraction of trace organic pollutants.

    Science.gov (United States)

    Liu, Shuqin; Hu, Qingkun; Zheng, Juan; Xie, Lijun; Wei, Songbo; Jiang, Ruifen; Zhu, Fang; Liu, Yuan; Ouyang, Gangfeng

    2016-06-10

    A series of knitting aromatic polymers (KAPs) were successfully synthesized using a simple one-step Friedel-Crafts alkylation of aromatic monomers and were characterized by transmission electron microscopy (TEM), Fourier transform infrared (FTIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Then, as-synthesized KAPs with large surface areas, unique pore structures and high thermal stability were prepared as solid-phase microextraction (SPME) coatings that exhibited good extraction abilities for a series of benzene compounds (i.e., benzene, toluene, ethylbenzene and m-xylene, which are referred to as BTEX) and polycyclic aromatic hydrocarbons (PAHs). Under the optimized conditions, the methodologies established for the determination of BTEX and PAHs using the KAPs-triPB and KAPs-B coatings, respectively, possessed wide linear ranges, low limits of detection (LODs, 0.10-1.13ngL(-1) for BTEX and 0.05-0.49ngL(-1) for PAHs) and good reproducibility. Finally, the proposed methods were successfully applied to the determination of BTEX and PAHs in environmental water samples, and satisfactory recoveries (93.6-124.2% for BTEX and 77.2-113.3% for PAHs) were achieved. This study provides a benchmark for exploiting novel microporous organic polymers (MOPs) for SPME applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Solid phase microextraction: measurement of volatile organic compounds (VOCs) in Dhaka City air pollution.

    Science.gov (United States)

    Hussam, A; Alauddin, M; Khan, A H; Chowdhury, D; Bibi, H; Bhattacharjee, M; Sultana, S

    2002-08-01

    A solid phase microextraction (SPME) technique was applied for the sampling of volatile organic compounds (VOCs) in ambient air polluted by two stroke autorickshaw engines and automobile exhausts in Dhaka city, Bangladesh. Analysis was carried out by capillary gas chromatography (GC) and GC-mass spectrometry (MS). The methodology was tested by insitu sampling of an aromatic hydrocarbon mixture gas standard with a precision of +/-5% and an average accuracy of 1-20%. The accuracy for total VOCs concentration measurement was about 7%. VOC's in ambient air were collected by exposing the SPME fiber at four locations in Dhaka city. The chromatograms showed signature similar to that of unburned gasoline (petrol) and weathered diesel containing more than 200 organic compounds; some of these compounds were positively identified. These are normal hydrocarbons pentane (n-C5H2) through nonacosane (n-C29H60), aromatic hydrocarbons: benzene, toluene, ethylbenzene, n-propylbenzene, n-butylbenzene, 1,3,5-trimethylbenzene, xylenes, and 1-isocyanato-3-methoxybenzene. Two samples collected near an autorickshaw station contained 783000 and 1479000 microg/m3 of VOCs. In particular, the concentration of toluene was 50-100 times higher than the threshold limiting value of 2000 microg/m3. Two other samples collected on street median showed 135000 microg/m3 and 180000 microg/m3 of total VOCs. The method detection limit of the technique for most semi-volatile organic compounds was 1 microg/m3.

  11. Analysis of lignocellulose derived phenolic monomers by headspace solid-phase microextraction and gas chromatography.

    Science.gov (United States)

    Kolb, Michaela; Schieder, Doris; Faulstich, Martin; Sieber, Volker

    2013-09-13

    A headspace solid-phase microextraction method with subsequent GC-MS (HS-SPME/GC-MS) was established for the quantitative analysis of volatile lignin derived phenolic monomers in complex aqueous solutions. Extraction was done using a polyacrylate fiber. The optimization of HS-SPME - parameters was performed using a multi component model solution of six representative phenolic monomers identified in liquid hot water (LHW) supernatants of hydrothermally treated lignocellulosic biomass: p-coumaric acid, guaiacol, vanillin, acetosyringone, 4-hydroxy-3-methoxyphenylacetone, and acetophenone. Plackett-Burman design was applied for pre-evaluation and 2(3) central composite designs with star points for parameter optimization. LOQ (S/N>10) and LOD (S/N>3) were determined for 12 phenols yielding LOQ of <0.005-618nM and LOD of <0.005-412nM. Within-day and between-day tests (n=6) showed different results for the tested phenols. RSD ranged from 2% to 30% and recovery rates from 99% to 160% in LHW matrix. Tests on storage of LHW supernatants for several weeks indicated a considerable influence of temperature on the stability of the solutions which may even have to be taken into account for auto sampler handling. All in all the method allows a fast and solvent free analysis requiring low sample volumes making it a powerful tool for screening or high-throughput analysis of aqueous solutions of lignin derived aromatics. Copyright © 2013. Published by Elsevier B.V.

  12. Sampling gaseous compounds from essential oils evaporation by solid phase microextraction devices

    Science.gov (United States)

    Cheng, Wen-Hsi; Lai, Chin-Hsing

    2014-12-01

    Needle trap samplers (NTS) are packed with 80-100 mesh divinylbenzene (DVB) particles to extract indoor volatile organic compounds (VOCs). This study compared extraction efficiency between an NTS and a commercially available 100 μm polydimethylsiloxane-solid phase microextration (PDMS-SPME) fiber sampler used to sample gaseous products in heated tea tree essential oil in different evaporation modes, which were evaporated respectively by free convection inside a glass evaporation dish at 27 °C, by evaporation diffuser at 60 °C, and by thermal ceramic wicks at 100 °C. The experimental results indicated that the NTS performed better than the SPME fiber samplers and that the NTS primarily adsorbed 5.7 ng ethylbenzene, 5.8 ng m/p-xylenes, 11.1 ng 1,2,3-trimethylbenzene, 12.4 ng 1,2,4-trimethylbenzene and 9.99 ng 1,4-diethylbenzene when thermal ceramic wicks were used to evaporate the tea tree essential oil during a 1-hr evaporation period. The experiment also indicated that the temperature used to heat the essential oils should be as low as possible to minimize irritant VOC by-products. If the evaporation temperature does not exceed 100 °C, the concentrations of main by-products trimethylbenzene and diethylbenzene are much lower than the threshold limit values recommended by the National Institute for Occupational Safety and Health (NIOSH).

  13. [Analyze on volatile compounds of Antrodia camphorata using HS-SPME-GC-MS].

    Science.gov (United States)

    He, Zhe; Lu, Zhen-Ming; Xu, Hong-Yu; Shi, Jing-Song; Xu, Zheng-Hong

    2011-11-01

    To analyze the volatile compounds of Antrodia camphorata in solid-state and submerged cultures. A headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry(GC-MS) were used to evaluate the profile of the volatile compounds. 49 volatile compounds were identified in A. camphorata mycelia in submerged culture, while 43 volatile compounds were identified in mycelia in solid-state culture. 1-octen-3-ol, 3-octanone, 1-octen-3-ylacetate, acetic acid octyl ester and ethanol were the main volatile compounds in A. camphorata mycelia in submerged culture, while 1-octen-3-ol, 3-octanone, 3-methyl-butyraldenhyde, gamma-podecalactone and methyl 2-furozte were the most potent key volatile compounds in mycelia in solid-state culture. The volatile compounds in the mycelia of A. camphorata in solid-state and submerged cultures are similar but their relative contents are different.

  14. Phase transitions in solids under high pressure

    CERN Document Server

    Blank, Vladimir Davydovich

    2013-01-01

    Phase equilibria and kinetics of phase transformations under high pressureEquipment and methods for the study of phase transformations in solids at high pressuresPhase transformations of carbon and boron nitride at high pressure and deformation under pressurePhase transitions in Si and Ge at high pressure and deformation under pressurePolymorphic α-ω transformation in titanium, zirconium and zirconium-titanium alloys Phase transformations in iron and its alloys at high pressure Phase transformations in gallium and ceriumOn the possible polymorphic transformations in transition metals under pressurePressure-induced polymorphic transformations in АIBVII compoundsPhase transformations in AIIBVI and AIIIBV semiconductor compoundsEffect of pressure on the kinetics of phase transformations in iron alloysTransformations during deformation at high pressure Effects due to phase transformations at high pressureKinetics and hysteresis in high-temperature polymorphic transformations under pressureHysteresis and kineti...

  15. Silica Modified with Polyaniline as a Potential Sorbent for Matrix Solid Phase Dispersion (MSPD and Dispersive Solid Phase Extraction (d-SPE of Plant Samples

    Directory of Open Access Journals (Sweden)

    Ireneusz Sowa

    2018-03-01

    Full Text Available Polyaniline (PANI is one of the best known conductive polymers with multiple applications. Recently, it was also used in separation techniques, mostly as a component of composites for solid-phase microextraction (SPME. In the present paper, sorbent obtained by in situ polymerization of aniline directly on silica gel particles (Si-PANI was used for dispersive solid phase extraction (d-SPE and matrix solid–phase extraction (MSPD. The efficiency of both techniques was evaluated with the use of high performance liquid chromatography with diode array detection (HPLC-DAD quantitative analysis. The quality of the sorbent was verified by Raman spectroscopy and microscopy combined with automated procedure using computer image analysis. For extraction experiments, triterpenes were chosen as model compounds. The optimal conditions were as follows: protonated Si-PANI impregnated with water, 160/1 sorbent/analyte ratio, 3 min of extraction time, 4 min of desorption time and methanolic solution of ammonia for elution of analytes. The proposed procedure was successfully used for pretreatment of plant samples.

  16. HS-SPME-GC-MS ANALYSIS OF VOLATILE AND SEMI-VOLATILE COMPOUNDS FROM DRIED LEAVES OF Mikania glomerata Sprengel

    Directory of Open Access Journals (Sweden)

    Esmeraldo A. Cappelaro

    2015-03-01

    Full Text Available This paper reports on the identification of volatile and semi-volatile compounds and a comparison of the chromatographic profiles obtained by Headspace Solid-Phase Microextraction/Gas Chromatography with Mass Spectrometry detection (HS-SPME-GC-MS of dried leaves of Mikania glomerata Sprengel (Asteraceae, also known as 'guaco.' Three different types of commercial SPME fibers were tested: polydimethylsiloxane (PDMS, polydimethylsiloxane/divinylbenzene (PDMS/DVB and polyacrylate (PA. Fifty-nine compounds were fully identified by HS-SPME-HRGC-MS, including coumarin, a marker for the quality control of guaco-based phytomedicines; most of the other identified compounds were mono- and sesquiterpenes. PA fibers performed better in the analysis of coumarin, while PDMS-DVB proved to be the best choice for a general and non-selective analysis of volatile and semi-volatile guaco-based compounds. The SPME method is faster and requires a smaller sample than conventional hydrodistillation of essential oils, providing a general overview of the volatile and semi-volatile compounds of M. glomerata.

  17. Separation and identification of volatile constituents in Artemisia argyi flowers by GC-MS with SPME and steam distillation.

    Science.gov (United States)

    Li, Ning; Mao, Yu; Deng, Chunhui; Zhang, Xiangmin

    2008-01-01

    Artemisia argyi leaf is a widely used traditional Chinese medicine (TCM). In this work, for the first time, the separation and identification of volatile constituents in Artemisia argyi flowers is performed. Gas chromatography-mass spectrometry (GC-MS) with solid-phase microextraction (SPME) is developed for the fast analysis of volatile constituents in the flowers. Several headspace SPME parameters, including fiber coating, extraction temperature, and extraction time, are optimized. Forty-nine compounds in the flowers are re-identified by SPME-GC-MS. At the same time, in order to compare with the SPME, steam distillation is used for analysis of the volatile constituents in the flowers, and forty-seven are detected. The total fifty-three compounds in the flowers, which mainly include cylcofenchene, alpha-pinene, alpha-myrcene, D-limonene, caryophyllene, and germacrene D, are identified by the two methods. Compared to the volatile components in Artemisia argyi leaves, the main components (including the two active compounds of borneol and borneol acetate) are also found in Artemisia argyi flowers. These results show that Artemisia argyi flowers as well as leaves might be used as TCM.

  18. Identification of odor signature chemicals in cocaine using solid-phase microextraction-gas chromatography and detector-dog response to isolated compounds spiked on U.S. paper currency.

    Science.gov (United States)

    Furton, Kenneth G; Hong, Yi-Cheng; Hsu, Ya-Li; Luo, Tianying; Rose, Stefan; Walton, John

    2002-03-01

    Solid-phase microextraction (SPME) combined with gas chromatography (GC) is optimized and applied to the analysis of street-cocaine samples followed by the field-testing of isolated chemicals using certified detector dogs. SPME proves to be a very sensitive and rapid method for isolating odor chemicals from street-cocaine samples. SPME-GC and activated charcoal strip (ACS)-SPME-GC signature profile methods are developed for the detection and quantitation of cocaine-odor chemicals, including the optimization of controllable variables such as fiber chemistry, extraction time, and desorption time. The volatile odor chemicals in representative illicit cocaine samples are identified and quantitated by the ACS-SPME-GC signature profile method and direct injection. Field tests with drug detector dogs show methyl benzoate to be the dominant signature odor chemical along with cocaine on U.S. currency at a threshold level of approximately 1-10 microg when spiked or when 10 ng/s methyl benzoate is diffused from polymer bottles, which is required in order to initiate an alert. No other substance studied initiated consistent responses by the drug dogs. The results indicate that the microgram levels of cocaine that have been reported on circulated U.S. currency are insufficient to signal an alert from law-enforcement trained drug detector dogs.

  19. Headspace Solid-Phase Microextraction Analysis of Volatile Components in Phalaenopsis Nobby’s Pacific Sunset

    Directory of Open Access Journals (Sweden)

    Chih-Hsin Yeh

    2014-09-01

    Full Text Available Phalaenopsis is the most important economic crop in the Orchidaceae family. There are currently numerous beautiful and colorful Phalaenopsis flowers, but only a few species of Phalaenopsis have an aroma. This study reports the analysis volatile components present in P. Nobby’s Pacific Sunset by solid-phase microextraction (SPME coupled with gas chromatography (GC and gas chromatography/mass spectrometry (GC-MS. The results show that the optimal extraction conditions were obtained by using a DVB/CAR/PDMS fiber. A total of 31 compounds were identified, with the major compounds being geraniol, linalool and α-farnesene. P. Nobby’s Pacific Sunset had the highest odor concentration from 09:00 to 13:00 on the eighth day of storage. It was also found that in P. Nobby’s Pacific Sunset orchids the dorsal sepals and petals had the highest odor concentrations, whereas the column had the lowest.

  20. Comparative evaluation of liquid-liquid extraction, solid-phase extraction and solid-phase microextraction for the gas chromatography-mass spectrometry determination of multiclass priority organic contaminants in wastewater.

    Science.gov (United States)

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2013-12-15

    The European Water Framework Directive (WFD) 2000/60/EC establishes guidelines to control the pollution of surface water by sorting out a list of priority substances that involves a significant risk to or via the aquatic systems. In this article, the analytical performance of three different sample preparation methodologies for the GC-MS/MS determination of multiclass organic contaminants-including priority comprounds from the WFD-in wastewater samples using gas chromatography-mass spectrometry was evaluated. The methodologies tested were: (a) liquid-liquid extraction (LLE) with n-hexane; (b) solid-phase extraction (SPE) with C18 cartridges and elution with ethyl acetate:dichloromethane (1:1 (v/v)), and (c) headspace solid-phase microextraction (HS-SPME) using two different fibers: polyacrylate and polydimethylsiloxane/carboxen/divinilbenzene. Identification and confirmation of the selected 57 compounds included in the study (comprising polycyclic aromatic hydrocarbons (PAHs), pesticides and other contaminants) were accomplished using gas chromatography tandem mass spectrometry (GC-MS/MS) with a triple quadrupole instrument operated in the multiple reaction monitoring (MRM) mode. Three MS/MS transitions were selected for unambiguous confirmation of the target chemicals. The different advantages and pitfalls of each method were discussed. In the case of both LLE and SPE procedures, the method was validated at two different concentration levels (15 and 150 ng L(-1)) obtaining recovery rates in the range 70-120% for most of the target compounds. In terms of analyte coverage, results with HS-SPME were not satisfactory, since 14 of the compounds tested were not properly recovered and the overall performance was worse than the other two methods tested. LLE, SPE and HS-SPME (using polyacrylate fiber) procedures also showed good linearity and precision. Using any of the three methodologies tested, limits of quantitation obtained for most of the detected compounds were in

  1. SPME GC/MS determination of organochlorine pesticides in water samples

    Directory of Open Access Journals (Sweden)

    Yerbolat Sailaukhanuly

    2013-05-01

    Full Text Available Headspace solid phase microextraction (HS-SPME in combination with gas chromatography and mass-spectrometry (GC/MS was studied for analysis of water samples. The organochlorine pesticides (OCPs, p,p'-DDT, p,p'-DDD, and p,p'-DDE were collected and analyzed by GC/MS. To select of effective fiber coatings four types of SPME fibers were examined and compared. The parameters effecting the efficiency of HS-SPME such as extraction and pre-incubation time and extraction temperature, effect of solvent nature, ionic strength were studied to obtain optimal parameters. The method was developed using spiked water samples in a concentration range  10 - 500 ng/L. The calibration curve was linear over the studied concentration range with r≥0.9925. The detection limits varied from 1.57 to 2.08 ng/L. An authentic water samples from contaminated lake with OCPs were analyzed by developed method.

  2. Quantification of benzene, toluene, ethylbenzene and o-xylene in internal combustion engine exhaust with time-weighted average solid phase microextraction and gas chromatography mass spectrometry.

    Science.gov (United States)

    Baimatova, Nassiba; Koziel, Jacek A; Kenessov, Bulat

    2015-05-11

    A new and simple method for benzene, toluene, ethylbenzene and o-xylene (BTEX) quantification in vehicle exhaust was developed based on diffusion-controlled extraction onto a retracted solid-phase microextraction (SPME) fiber coating. The rationale was to develop a method based on existing and proven SPME technology that is feasible for field adaptation in developing countries. Passive sampling with SPME fiber retracted into the needle extracted nearly two orders of magnitude less mass (n) compared with exposed fiber (outside of needle) and sampling was in a time weighted-averaging (TWA) mode. Both the sampling time (t) and fiber retraction depth (Z) were adjusted to quantify a wider range of Cgas. Extraction and quantification is conducted in a non-equilibrium mode. Effects of Cgas, t, Z and T were tested. In addition, contribution of n extracted by metallic surfaces of needle assembly without SPME coating was studied. Effects of sample storage time on n loss was studied. Retracted TWA-SPME extractions followed the theoretical model. Extracted n of BTEX was proportional to Cgas, t, Dg, T and inversely proportional to Z. Method detection limits were 1.8, 2.7, 2.1 and 5.2 mg m(-3) (0.51, 0.83, 0.66 and 1.62 ppm) for BTEX, respectively. The contribution of extraction onto metallic surfaces was reproducible and influenced by Cgas and t and less so by T and by the Z. The new method was applied to measure BTEX in the exhaust gas of a Ford Crown Victoria 1995 and compared with a whole gas and direct injection method. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Applicability of solid-phase microextraction combined with gas chromatography atomic emission detection (GC-MIP AED) for the determination of butyltin compounds in sediment samples

    Energy Technology Data Exchange (ETDEWEB)

    Carpinteiro, J.; Rodriguez, I.; Cela, R. [Universidad de Santiago de Compostela, Departamento de Quimica Analitica, Nutricion y Bromatologia, Instituto de Investigacion y Analisis Alimentario, Santiago de Compostela 15782 (Spain)

    2004-11-01

    The performance of solid-phase microextraction (SPME) applied to the determination of butyltin compounds in sediment samples is systematically evaluated. Matrix effects and influence of blank signals on the detection limits of the method are studied in detail. The interval of linear response is also evaluated in order to assess the applicability of the method to sediments polluted with butyltin compounds over a large range of concentrations. Advantages and drawbacks of including an SPME step, instead of the classic liquid-liquid extraction of the derivatized analytes, in the determination of butyltin compounds in sediment samples are considered in terms of achieved detection limits and experimental effort. Analytes were extracted from the samples by sonication using glacial acetic acid. An aliquot of the centrifuged extract was placed on a vial where compounds were ethylated and concentrated on a PDMS fiber using the headspace mode. Determinations were carried out using GC-MIP AED. (orig.)

  4. Speciation of mercury compounds by gas chromatography with atomic emission detection. Simultaneous optimization of a headspace solid-phase microextraction and derivatization procedure by use of chemometric techniques

    Energy Technology Data Exchange (ETDEWEB)

    Carro, A.M.; Neira, I.; Rodil, R.; Lorenzo, R. A. [Univ. Santiago de Compostela (Spain). Dpto. Quimica Analitica, Nutricion y Bromatologia

    2003-06-01

    A method is proposed for the extraction and determination of organomercury compounds and Hg(II) in seawater samples by headspace solid-phase microextraction (HS-SPME) combined with capillary gas chromatography-microwave-induced plasma atomic emission spectrometry. The mercury species were derivatized with sodium tetraphenylborate, sorbed on a polydimethylsiloxane-coated fused-silica fibre, and desorbed in the injection port of the GC, in splitless mode. Experimental design methodology was used to evaluate the effect of six HS-SPME-derivatization variables: sample volume, NaBPh{sub 4} volume, pH, sorption time, extraction-derivatization temperature, and rate of stirring. Use of a multicriterion decision-making approach, with the desirability function, enabled determination of the optimum working conditions of the procedure for simultaneous analysis of three mercury species. (orig.)

  5. Cadmium(II)-based metal-organic nanotubes as solid-phase microextraction coating for ultratrace-level analysis of polychlorinated biphenyls in seawater samples.

    Science.gov (United States)

    Sheng, Wan-Ru; Chen, Yue; Wang, Shan-Shan; Wang, Xiao-Li; Wang, Ming-Lin; Zhao, Ru-Song

    2016-11-01

    In this study, stable cadmium(II)-based metal-organic nanotubes (Cd-MONTs) were prepared and used as a coating material for solid-phase microextraction (SPME) of polychlorinated biphenyls (PCBs) from environmental water samples. The as-prepared Cd-MONT SPME coating material was characterized by thermal gravimetric analysis, scanning electron microscopy, and X-ray diffraction. The synthesized Cd-MONTs exhibited high thermal stability (385 °C) and excellent extraction performance toward PCBs. The important conditions were optimized systematically by the response surface method. Under the optimal conditions, the new fiber achieved high enrichment factors (938-3417), low limits of detection (1.80-8.73 pg L -1 ), and wide linearity (10-5000 pg L -1 ). The method developed was used in ultratrace-level analysis of PCBs in seawater samples, with satisfactory results for each sample.

  6. Mesoporous VN prepared by solid-solid phase separation

    Energy Technology Data Exchange (ETDEWEB)

    Yang Minghui, E-mail: m.yang@cornell.edu [Department of Chemistry, Cornell University, Ithaca, New York 14853-1301 (United States); Ralston, Walter T. [Department of Chemistry, Cornell University, Ithaca, New York 14853-1301 (United States); Tessier, Franck [UMR CNRS 6226 ' Sciences Chimiques de Rennes' , Equipe ' Verres et Ceramiques' , Universite de Rennes 1, F-35042 Rennes cedex (France); Allen, Amy J. [Department of Chemistry, Cornell University, Ithaca, New York 14853-1301 (United States); DiSalvo, Francis J., E-mail: fjd3@cornell.edu [Department of Chemistry, Cornell University, Ithaca, New York 14853-1301 (United States)

    2013-01-15

    We recently reported a simple route to prepare mesoporous, conducting nitrides from Zn containing ternary transition metal oxides. Those materials result from the condensation of atomic scale voids created by the loss of Zn by evaporation, the replacement of 3 oxygen anions by 2 nitrogen anions, and in most cases the loss of oxygen to form water on the reduction of the transition metal. In this report, we present a different route to prepare mesoporous VN from K containing vanadium oxides. In this case, ammonolysis results in a multiphase solid product that contains VN, and other water soluble compounds such as KOH or KNH{sub 2}. On removing the K containing products by washing with degassed water, only mesoporous VN remains. VN materials with different pore sizes (10 nm-20 nm) were synthesized at 600 Degree-Sign C by varying the reaction time, while larger pores are obtained at higher temperatures (50 nm at 800 Degree-Sign C). - Graphical Abstract: The synthesis process of mesoporous VN from solid-solid separation. Highlights: Black-Right-Pointing-Pointer Mesoporous VN has been prepared by solid-solid phase separation. Black-Right-Pointing-Pointer Mesoporous VN was characterized by Rietveld refinement of PXRD, SEM and nitrogen physisorption. Black-Right-Pointing-Pointer VN materials with different pore sizes (10 nm-50 nm) were synthesized.

  7. Evaluation of Superparamagnetic Silica Nanoparticles for Extraction of Triazines in Magnetic in-Tube Solid Phase Microextraction Coupled to Capillary Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    R. A. González-Fuenzalida

    2014-04-01

    Full Text Available The use of magnetic nanomaterials for analytical applications has increased in the recent years. In particular, magnetic nanomaterials have shown great potential as adsorbent phase in several extraction procedures due to the significant advantages over the conventional methods. In the present work, the influence of magnetic forces over the extraction efficiency of triazines using superparamagnetic silica nanoparticles (NPs in magnetic in tube solid phase microextraction (Magnetic-IT-SPME coupled to CapLC has been evaluated. Atrazine, terbutylazine and simazine has been selected as target analytes. The superparamagnetic silica nanomaterial (SiO2-Fe3O4 deposited onto the surface of a capillary column gave rise to a magnetic extraction phase for IT-SPME that provided a enhancemment of the extraction efficiency for triazines. This improvement is based on two phenomena, the superparamegnetic behavior of Fe3O4 NPs and the diamagnetic repulsions that take place in a microfluidic device such a capillary column. A systematic study of analytes adsorption and desorption was conducted as function of the magnetic field and the relationship with triazines magnetic susceptibility. The positive influence of magnetism on the extraction procedure was demonstrated. The analytical characteristics of the optimized procedure were established and the method was applied to the determination of the target analytes in water samples with satisfactory results. When coupling Magnetic-IT-SPME with CapLC, improved adsorption efficiencies (60%–63% were achieved compared with conventional adsorption materials (0.8%–3%.

  8. Multiplexed Colorimetric Solid-Phase Extraction

    Science.gov (United States)

    Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.

    2009-01-01

    Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).

  9. Solid phase tube radioimmunoassay for digoxin detection

    International Nuclear Information System (INIS)

    Stellner, K.; Glatz, C.; Linke, R.

    1975-01-01

    A solid phase radioimmunoassay with 125 I is described for cardiac patients. The test for the digoxin determination and the poisoning due to cardiac glycosides can be measured very accurately and carried out easily. In addition, the test determination can be automatically performed in connection with other tests. (GSE/LH) [de

  10. Determination of multi-class herbicides in soil by liquid-solid extraction coupled with headspace solid phase microextraction method

    Directory of Open Access Journals (Sweden)

    Đurović-Pejčev Rada

    2016-01-01

    Full Text Available A method is described for simultaneous determination of five herbicides (metribuzin, acetochlor, clomazone, oxyfluorfen and dimethenamid belonging to different pesticides groups in soil samples. Developed headspace solid phase microextraction method (HS-SPME in combination with liquid-solid sample preparation (LS was optimized and applied in the analysis of some agricultural samples. Optimization of microextraction conditions, such as temperature, extraction time and sodium chloride (NaCl content was perfor-med using 100 μm polydimethyl-siloxane (PDMS fiber. The extraction effi-ciencies of methanol, methanol:acetone=1:1 and methanol:acetone:hexane= =2:2:1 and the optimum number of extraction steps during the sample prepa-ration, were tested, as well. Gas chromatography-mass spectrometry (GC-MS was used for detection and quantification, obtaining relative standard deviation (RSD below 13%, and recovery values higher than 83% for multiple analyses of soil samples fortified at 30 μg kg-1 of each herbicide. Limits of detection (LOD were less than 1.2 μg kg-1 for all the studied herbicides. [Projekat Ministarstva nauke Republike Srbije, br. TR31043 i br. III43005

  11. A comparison of sample preparation methods for extracting volatile organic compounds (VOCs) from equine faeces using HS-SPME.

    Science.gov (United States)

    Hough, Rachael; Archer, Debra; Probert, Christopher

    2018-01-01

    Disturbance to the hindgut microbiota can be detrimental to equine health. Metabolomics provides a robust approach to studying the functional aspect of hindgut microorganisms. Sample preparation is an important step towards achieving optimal results in the later stages of analysis. The preparation of samples is unique depending on the technique employed and the sample matrix to be analysed. Gas chromatography mass spectrometry (GCMS) is one of the most widely used platforms for the study of metabolomics and until now an optimised method has not been developed for equine faeces. To compare a sample preparation method for extracting volatile organic compounds (VOCs) from equine faeces. Volatile organic compounds were determined by headspace solid phase microextraction gas chromatography mass spectrometry (HS-SPME-GCMS). Factors investigated were the mass of equine faeces, type of SPME fibre coating, vial volume and storage conditions. The resultant method was unique to those developed for other species. Aliquots of 1000 or 2000 mg in 10 ml or 20 ml SPME headspace were optimal. From those tested, the extraction of VOCs should ideally be performed using a divinylbenzene-carboxen-polydimethysiloxane (DVB-CAR-PDMS) SPME fibre. Storage of faeces for up to 12 months at - 80 °C shared a greater percentage of VOCs with a fresh sample than the equivalent stored at - 20 °C. An optimised method for extracting VOCs from equine faeces using HS-SPME-GCMS has been developed and will act as a standard to enable comparisons between studies. This work has also highlighted storage conditions as an important factor to consider in experimental design for faecal metabolomics studies.

  12. Optimization of HS-SPME/GC-MS analysis and its use in the profiling of illicit ecstasy tablets (Part 1).

    Science.gov (United States)

    Bonadio, Federica; Margot, Pierre; Delémont, Olivier; Esseiva, Pierre

    2009-05-30

    A headspace solid-phase microextraction procedure (HS-SPME) was developed for the profiling of traces present in 3,4-methylenedioxymethylampethamine (MDMA). Traces were first extracted using HS-SPME and then analyzed by gas chromatography-mass spectroscopy (GC-MS). The HS-SPME conditions were optimized using varying conditions. Optimal results were obtained when 40 mg of crushed MDMA sample was heated at 80 degrees C for 15 min, followed by extraction at 80 degrees C for 15 min with a polydimethylsiloxane/divinylbenzene coated fibre. A total of 31 compounds were identified as traces related to MDMA synthesis, namely precursors, intermediates or by-products. In addition some fatty acids used as tabletting materials and caffeine used as adulterant, were also detected. The use of a restricted set of 10 target compounds was also proposed for developing a screening tool for clustering samples having close profile. 114 seizures were analyzed using an SPME auto-sampler (MultiPurpose Samples MPS2), purchased from Gerstel GMBH & Co. (Germany), and coupled to GC-MS. The data was handled using various pre-treatment methods, followed by the study of similarities between sample pairs based on the Pearson correlation. The results show that HS-SPME, coupled with the suitable statistical method is a powerful tool for distinguishing specimens coming from the same seizure and specimens coming from different seizures. This information can be used by law enforcement personnel to visualize the ecstasy distribution network as well as the clandestine tablet manufacturing.

  13. Phase 2, Solid waste retrieval strategy

    International Nuclear Information System (INIS)

    Johnson, D.M.

    1994-01-01

    Solid TRU retrieval, Phase 1 is scheduled to commence operation in 1998 at 218W-4C-T01 and complete recovery of the waste containers in 2001. Phase 2 Retrieval will recover the remaining buried TRU waste to be retrieved and provide the preliminary characterization by non-destructive means to allow interim storage until processing for disposal. This document reports on researching the characterization documents to determine the types of wastes to be retrieved and where located, waste configurations, conditions, and required methods for retrieval. Also included are discussions of wastes encompassed by Phase 2 for which there are valid reasons to not retrieve

  14. Phase 2, Solid waste retrieval strategy

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, D.M.

    1994-09-29

    Solid TRU retrieval, Phase 1 is scheduled to commence operation in 1998 at 218W-4C-T01 and complete recovery of the waste containers in 2001. Phase 2 Retrieval will recover the remaining buried TRU waste to be retrieved and provide the preliminary characterization by non-destructive means to allow interim storage until processing for disposal. This document reports on researching the characterization documents to determine the types of wastes to be retrieved and where located, waste configurations, conditions, and required methods for retrieval. Also included are discussions of wastes encompassed by Phase 2 for which there are valid reasons to not retrieve.

  15. First results on headspace-solid phase microextraction-gas chromatography/mass spectrometry of volatile organic compounds emitted by wax objects in museums.

    Science.gov (United States)

    Lattuati-Derieux, A; Thao, S; Langlois, J; Regert, M

    2008-04-11

    Sampling volatile organic compounds (VOCs) emitted by a large variety of materials is nowadays a very useful technique for analytical purpose. In the field of cultural heritage, it can be applied to identify some constituents of museum artefacts off-gassing VOCs without sampling on the object itself. In this study, we focused on objects made of wax. First volatiles emitted by a reference beeswax were trapped and identified by headspace-solid phase microextraction (HS-SPME)-gas chromatography and mass spectrometry (GC/MS). This allowed to identify numerous volatile biomarkers, namely saturated n-alkanes from C(10) to C(21), saturated n-carboxylic acids containing 6-12 carbon atoms, benzene and cinnamic derivatives that may be considered as volatile biomarkers of beeswax. The SPME strategy was then performed at the Orsay museum (Paris) in a showcase containing a wax sculpture "Le Mineur de la Loire" by J.-J. Carriès. The use of beeswax in this sculpture was unequivocally confirmed by the VOCs concentrated in the showcase, together with a set of characteristic molecular compounds identified by HT-GC/MS. HS-SPME-GC/MS thus appears to be a powerful in situ and non-invasive analytical technique that allows to identify natural substances in the field of cultural heritage without any sampling of solid matter from the object. The results obtained are promising for orientating the strategy of preventive conservation related to works of art characterised by important emission of VOCs.

  16. SPME-based air sampling method for inhalation exposure assessment studies: case study on perchlorethylene exposure in dry cleaning.

    Science.gov (United States)

    Zare Sakhvidi, Mohammad Javad; Bahrami, Abdul Rahman; Ghiasvand, Alireza; Mahjub, Hossein; Tuduri, Ludovic

    2013-06-01

    Exposure to perchlorethylene, especially for dry cleaning workers and for people living near dry cleaning shops, could lead to several diseases and disorders. This study examines the value of solid-phase microextraction (SPME) for sampling perchlorethylene in the atmosphere of dry cleaning shops. Carboxen/polydimethylsiloxane (CAR/PDMS) in 0.5-cm retracted mode was selected. There were no significant differences between sampling rates at different temperatures (range of 20 to 30 °C) and air velocities (2 to 50 cm/s). On the opposite, relative humidity (RH) had a significant effect on sampling rates. Method reproducibility was realized in the laboratory and field conditions and was 6.2 % and 7 to 11 %, respectively. Repeatability was also determined as 8.9 %. Comparison of the results according to the American Industrial Hygiene Association exposure assessment strategy showed the SPME sampler yields more conservative results in comparison with traditional standard method.

  17. The Determination of Sediment Polycyclic Aromatic Hydrocarbon (PAH) Bioavailability using Direct Pore Water Analysis by Solid-Phase Microextraction (SPME)

    Science.gov (United States)

    2010-08-01

    include metals used in ordnance production and paint-spraying; solvents use in cleaning; cyanide and phenols use in the cooling process; creosote ...carbon dioxide extraction, and field bioremediation . Environ. Sci. Technol. 35:4577-4583. Hawthorne SB, Poppendieck DG, Grabanski CB, Loehr RC. 2002...Supercritical Carbon Dioxide Extraction, and Field Bioremediation ,” Hawthorne, Steven B., et al., Environmental Science & Technology, Vol. 35, No. 22, 2001

  18. Analysis of the volatiles in the headspace above the plasmodium and sporangia of the slime mould (Physarum polycephalum) by SPME-GCMS

    OpenAIRE

    Kateb, Huda al; Costello, Ben de Lacy

    2013-01-01

    Solid phase micro-extraction (SPME) coupled with Gas Chromatography Mass Spectrometry (GC-MS) was used to extract and analyse the volatiles in the headspace above the plasmodial and sporulating stages of the slime mould Physarum Polycephalum. In total 115 compounds were identified from across a broad range of chemical classes. Although more (87) volatile organic compounds (VOCs) were identified when using a higher incubation temperature of 75oC, a large number of compounds (79) were still ide...

  19. Analysis of Odorants in Marking Fluid of Siberian Tiger (Panthera tigris altaica) Using Simultaneous Sensory and Chemical Analysis with Headspace Solid-Phase Microextraction and Multidimensional Gas Chromatography-Mass Spectrometry-Olfactometry

    OpenAIRE

    Simone B. Soso; Jacek A. Koziel

    2016-01-01

    Scent-marking is the most effective method of communication in the presence or absence of a signaler. These complex mixtures result in a multifaceted interaction triggered by the sense of smell. The objective was to identify volatile organic compound (VOC) composition and odors emitted by total marking fluid (MF) associated with Siberian tigers (Panthera tigris altaica). Siberian tiger, an endangered species, was chosen because its MF had never been analyzed. Solid phase microextraction (SPME...

  20. Solid-phase equilibria on Pluto's surface

    Science.gov (United States)

    Tan, Sugata P.; Kargel, Jeffrey S.

    2018-03-01

    Pluto's surface is covered by volatile ices that are in equilibrium with the atmosphere. Multicomponent phase equilibria may be calculated using a thermodynamic equation of state and, without additional assumptions, result in methane-rich and nitrogen-rich solid phases. The former is formed at temperature range between the atmospheric pressure-dependent sublimation and condensation points, while the latter is formed at temperatures lower than the sublimation point. The results, calculated for the observed 11 μbar atmospheric pressure and composition, are consistent with recent work derived from observations by New Horizons.

  1. Solid phase synthesis of purines from pyrimidines.

    Science.gov (United States)

    Di Lucrezia, R; Gilbert, I H; Floyd, C D

    2000-01-01

    In this paper the solid phase synthesis of various substituted purines is described starting from 4,6-dichloro-5-nitropyrimidine. The 4,6-dichloro-5-nitropyrimidine was coupled to Rink amide resin followed by displacement of the second chloride by an amino compound. Reduction of the nitro compound proved to be problematic but was achieved using lithium aluminum hydride/aluminum trichloride. The diamines (13) were then elaborated to purines by three different routes.

  2. DNA Extraction: Organic and Solid-Phase.

    Science.gov (United States)

    Altayari, Wafa

    2016-01-01

    DNA extraction remains a critical step in DNA profiling of biological material recovered from scenes of crime. In the forensic community several methods have gained popularity, including Chelex(®), organic extraction, and solid-phase extraction. While some laboratories streamlined their processes and only use one method we have retained several methods and continue to use these for different sample types. In this chapter we present three methods that have been used for several years in our laboratory.

  3. A star-shaped polythiophene dendrimer coating for solid-phase microextraction of triazole agrochemicals.

    Science.gov (United States)

    Abolghasemi, Mir Mahdi; Habibiyan, Rahim; Jaymand, Mehdi; Piryaei, Marzieh

    2018-02-14

    A nanostructured star-shaped polythiophene dendrimer was prepared and used as a fiber coating for headspace solid phase microextraction of selected triazolic pesticides (tebuconazole, hexaconazole, penconazole, diniconazole, difenoconazole, triticonazole) from water samples. The dendrimer with its large surface area was characterized by thermogravimetric analysis, UV-Vis spectroscopy and field emission scanning electron microscopy. It was placed on a stainless steel wire for use in SPME. The experimental conditions for fiber coating, extraction, stirring rate, ionic strength, pH value, desorption temperature and time were optimized. Following thermal desorption, the pesticides were quantified by GC-MS. Under optimum conditions, the repeatability (RSD) for one fiber (for n = 3) ranges from 4.3 to 5.6%. The detection limits are between 8 and 12 pg mL -1 . The method is fast, inexpensive (in terms of equipment), and the fiber has high thermal stability. Graphical abstract Schematic presentation of a nanostructured star-shaped polythiophene dendrimer for use in headspace solid phase microextraction of the triazolic pesticides (tebuconazole, hexaconazole, penconazole, diniconazole, difenoconazole, triticonazole). They were then quantified by gas chromatography-mass spectrometry.

  4. Recent progress, challenges and trends in trace determination of drug analysis using molecularly imprinted solid-phase microextraction technology.

    Science.gov (United States)

    Ansari, Saeedeh; Karimi, Majid

    2017-03-01

    The quantification of drugs in biological samples is a significant task for determination of the physiological efficiency in evaluated drugs in the drug discovery. To analysis of the chemical compounds at the trace and ultratrace levels, adequate analytical procedures should be applied. Therefore, sample preparation method undoubtedly is the most important stage in the trace determination process. In spite of the great growth of analytical instrumentation during the recent years, sample preparation is still nowadays considered the impasse of the all analytical procedure, especially in drugs analysis. Because of the low concentration level of drugs in blood, plasma, and the diversity of the metabolites, the chosen extraction technique should be almost perfect. Solid-phase microextraction (SPME) is a powerful, simple, fast and an equilibrium-based sample preparation method that permits integration of sampling, sample clean-up, and pre-concentration in a single solvent-free step for chemical analysis. Molecularly imprinted polymers (MIPs) that provided by the presence of a template during their synthesis are the stable polymers with molecular recognition abilities and excellent materials which provide selectivity to sample preparation. Because of its characteristics such as easy preparation, high selectivity, and chemical stability, MIP is widely utilized in many analytical fields. Accordingly, the molecular imprinting and SPME methods combination would prepare a strong analytical instrumentation which comprises simplicity, flexibility, and the selectivity characteristics of both methods. This review focuses on the application of solid-phase microextraction method coupled with molecularly imprinted polymers, namely molecularly imprinted solid-phase microextraction (MISPME), for trace determination in drug analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Rapid determination of 54 pharmaceutical and personal care products in fish samples using microwave-assisted extraction-Hollow fiber-Liquid/solid phase microextraction.

    Science.gov (United States)

    Zhang, Yi; Guo, Wen; Yue, Zhenfeng; Lin, Li; Zhao, Fengjuan; Chen, Peijin; Wu, Weidong; Zhu, Hong; Yang, Bo; Kuang, Yanyun; Wang, Jiong

    2017-04-15

    In this paper, a simple, rapid, solvent-less and environmental friendliness microextraction method, microwave-assisted extraction-hollow fiber-liquid/solid phase microextraction (MAE-HF-L/SME), was developed for simultaneous extraction and enrichment of 54 trace hydrophilic/lipophilic pharmaceutical and personal care products (PPCPs) from fish samples. A solid-phase extraction material, solid-phase microextraction (SPME) fiber, was synthesized. The SPME fiber had a homogeneous, loose structure and good mechanical properties, and they exhibited a good adsorption capacity for most PPCPs selected. The material formed the basis for the method of MAE-HF-L/SME. A method of liquid chromatography-high resolution mass spectroscopy (LC-HRMS) for analysis of 54 PPCPs. Under optimal synthesis and extraction conditions, the limits of detection (LODs, n=3) and the limits of quantitation (LOQs, n=10) for the 54 PPCPs were between 0.01-0.50μg·kg -1 and 0.052.00μg·kg -1 , respectively. Percent recoveries and the relative standard deviations (RSDs) in spiked fish samples (n=6) were between 56.3%-119.9% and 0.3%-17.1%, respectively. The microextraction process of 54 PPCPs in MAE-HF-L/SME took approximately 12min. The method has a low matrix interference and high enrichment factor and may be applicable for determination of 54 different PPCPs in fish samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Preparation and evaluation of graphene-coated solid-phase microextraction fiber

    Energy Technology Data Exchange (ETDEWEB)

    Chen Jinmei; Zou Jing; Zeng Jingbin; Song Xinhong; Ji Jiaojiao; Wang Yiru [Department of Chemistry and the Key Laboratory of Analytical Sciences of the Ministry of Education, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005 (China); Ha, Jaeho [Food Analysis Center, Korea Food Research Institute, San 46-1, Baekhyun, Bundang, Seongnam, Gyonggi Province 463-746 (Korea, Republic of); Chen Xi, E-mail: xichen@xmu.edu.cn [Department of Chemistry and the Key Laboratory of Analytical Sciences of the Ministry of Education, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005 (China); State Key Laboratory of Marine Environmental Science, Xiamen University, Xiamen 361005 (China)

    2010-09-23

    In this paper, a novel graphene (G) based solid-phase microextraction (SPME) fiber was firstly prepared by immobilizing the synthesized G on stainless steel wire as coating. The new fiber possessed a homogeneous, porous and wrinkled surface and showed excellent thermal (over 330 {sup o}C), chemical and mechanical stability, and long lifespan (over 250 extractions). The SPME performance of the G-coated fiber was evaluated in detail through extraction of six pyrethroid pesticides. Although the thickness of G-coated fiber was only 6-8 {mu}m, its extraction efficiencies were higher than those of two commercial fibers (PDMS, 100 {mu}m; PDMS/DVB, 65 {mu}m). This high extraction efficiency may be mainly attributed to huge delocalized {pi}-electron system of G, which shows strong {pi}-stacking interaction with pyrethroid pesticide. The G-coated fiber was applied in the gas chromatographic determination of six pyrethroids, and their limits of detection were found to be ranged from 3.69 to 69.4 ng L{sup -1}. The reproducibility for each single fiber was evaluated and the relative standard deviations (RSDs) were calculated to be in the range from 1.9% to 6.5%. The repeatability of fiber-to-fiber and batch-to-batch was 4.3-9.2% and 4.1-9.9%. The method developed was successfully applied to three pond water samples, and the recoveries were 83-110% at a spiking of 1 {mu}g L{sup -1}.

  7. Elementary excitations and phase transformations in solids

    International Nuclear Information System (INIS)

    Cowley, R.A.

    1985-01-01

    Neutron scattering is and will continue to be a uniquely powerful tool for the study of elementary excitations and phase transformations in solids. The paper examines a few recent experiments on molecular crystals, superionic materials, paramagnetic scattering and phase transitions to see what experimental features made these experiments possible, and hence to make suggestions about future needs. It is concluded that new instruments will extend the scope of neutron scattering studies to new excitations, that there is a need for higher resolution, particularly for phase transition studies, and that it will be important to use intensity information, discrimination against unwanted inelastic processes and polarization analysis to reliably measure the excitations in new materials. (author)

  8. Preparation by low-temperature nonthermal plasma of graphite fiber and its characteristics for solid-phase microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Luo Fan [Department of Environmental Engineering, State Key Laboratory of Clean Energy Utilization, Key Laboratory of Polluted Environment Remediation and Ecological Health, MOE, Zhejiang University, Hangzhou 310027 (China); Wu Zucheng [Department of Environmental Engineering, State Key Laboratory of Clean Energy Utilization, Key Laboratory of Polluted Environment Remediation and Ecological Health, MOE, Zhejiang University, Hangzhou 310027 (China)], E-mail: wuzc@zju.edu.cn; Tao Ping [Institute of Structural Mechanics, China Academy of Engineering Physics, Mianyang 621900 (China); Cong Yanqing [College of Environmental Science and Engineering, Zhejiang Gongshang University, Hangzhou 310012 (China)

    2009-01-05

    Low-temperature nonthermal plasma has been used to prepare solid-phase microextraction (SPME) fibers with high adsorbability, long-term serviceability, and high reproducibility. Graphite rods serving as fiber precursors were treated by an air plasma discharged at 15.2-15.5 kV for a duration of 8 min. Sampling results revealed that the adsorptive capacity of the homemade fiber was 2.5-34.6 times that of a polyacrylate (PA) fiber for alcohols (methanol, ethanol, isopropyl alcohol, n-butyl alcohol), and about 1.4-1.6 times and 2.5-5.1 times that of an activated carbon fiber (ACF) for alcohols and BTEX (benzene, toluene, ethylbenzene, and xylenes), respectively. It is confirmed from FTIR (Fourier transform infrared spectrophotometer) and SEM (scanning electron microscope) analyses that the improvement in the adsorptive performance attributed to increased surface energy and roughness of the graphite fiber. Using gas chromatography (GC)-flame-ionization detector (FID), the limits of detection (LODs) of the alcohols and BTEX ranged between 0.19 and 3.75 {mu}g L{sup -1}, the linear ranges were between 0.6 and 35619 {mu}g L{sup -1} with good linearity (R{sup 2} = 0.9964-0.9997). It was demonstrated that nonthermal plasma offers a fast and simple method for preparing an efficient graphite SPME fiber, and that SPME using the homemade fiber represents a sensitive and selective extraction method for the analysis of a wide range of organic compounds.

  9. Novel Electrosorption-Enhanced Solid-Phase Microextraction Device for Ultrafast In Vivo Sampling of Ionized Pharmaceuticals in Fish.

    Science.gov (United States)

    Qiu, Junlang; Wang, Fuxin; Zhang, Tianlang; Chen, Le; Liu, Yuan; Zhu, Fang; Ouyang, Gangfeng

    2018-01-02

    Decreasing the tedious sample preparation duration is one of the most important concerns for the environmental analytical chemistry especially for in vivo experiments. However, due to the slow mass diffusion paths for most of the conventional methods, ultrafast in vivo sampling remains challenging. Herein, for the first time, we report an ultrafast in vivo solid-phase microextraction (SPME) device based on electrosorption enhancement and a novel custom-made CNT@PPY@pNE fiber for in vivo sampling of ionized acidic pharmaceuticals in fish. This sampling device exhibited an excellent robustness, reproducibility, matrix effect-resistant capacity, and quantitative ability. Importantly, the extraction kinetics of the targeted ionized pharmaceuticals were significantly accelerated using the device, which significantly improved the sensitivity of the SPME in vivo sampling method (limits of detection ranged from 0.12 ng·g -1 to 0.25 ng·g -1 ) and shorten the sampling time (only 1 min). The proposed approach was successfully applied to monitor the concentrations of ionized pharmaceuticals in living fish, which demonstrated that the device and fiber were suitable for ultrafast in vivo sampling and continuous monitoring. In addition, the bioconcentration factor (BCF) values of the pharmaceuticals were derived in tilapia (Oreochromis mossambicus) for the first time, based on the data of ultrafast in vivo sampling. Therefore, we developed and validated an effective and ultrafast SPME sampling device for in vivo sampling of ionized analytes in living organisms and this state-of-the-art method provides an alternative technique for future in vivo studies.

  10. Determination of 3-chloropropane-1,2-diol in liquid hydrolyzed vegetable proteins and soy sauce by solid-phase microextraction and gas chromatography/mass spectrometry.

    Science.gov (United States)

    Huang, Minjia; Jiang, Guibin; He, Bin; Liu, Jingfu; Zhou, Qingxiang; Fu, Wusheng; Wu, Yongning

    2005-11-01

    Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography/mass spectrometry (GC/MS) method was developed to determine 3-chloropropane-1,2-diol (3-MCPD) in hydrolyzed vegetable protein and Chinese soy sauce. The 3-MCPD was firstly derivativized with phenylboronic acid in aqueous solution at 90 degrees C for 10 min, then extracted by HS-SPME and finally detected with GC/MS, parameters related to both the derivative reaction and the HS-SPME process were optimized. The proposed method has a linear range of 0.0194-394 microg g(-1), a detection limit of 3.87 ng g(-1) (S/N = 3), and a precision of RSD = 7.5% (n = 5). Seventeen real samples, including four HVPs and thirteen soy sauce samples, were analyzed to examine the feasibility of the proposed procedure; with a concentration of 3-MCPD and acceptable recoveries at 0.71 microg g(-1) spiked levels were obtained. Being simpler, faster and more environmentally benign than the existing methods, this method is accurate and suitable for routine analysis.

  11. Biocompatible in-tube solid phase microextraction coupled with liquid chromatography-fluorescence detection for determination of interferon α in plasma samples.

    Science.gov (United States)

    Chaves, Andréa R; Silva, Bruno J G; Lanças, Fernando M; Queiroz, Maria Eugênia C

    2011-05-27

    The present work demonstrates the successful application of automated biocompatible in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC) for determination of interferon alpha(2a) (IFN α(2a)) in plasma samples for therapeutic drug monitoring. A restricted access material (RAM, protein-coated silica) was employed for preparation of a lab-made biocompatible in-tube SPME capillary that enables the direct injection of biological fluids as well as the simultaneous exclusion of macromolecules by chemical diffusion barrier and drug pre-concentration. The in-tube SPME variables, such as sample volume, draw/eject volume, number of draw-eject cycles, and desorption mode were optimized, to improve the sensitivity of the proposed method. The IFN α(2a) analyses in plasma sample were carried out within 25min (sample preparation and LC analyses). The response of the proposed method was linear over a dynamic range, from 0.06 to 3.0MIUmL(-1), with correlation coefficient equal to 0.998. The interday precision of the method presented coefficient of variation lower than 8%. The proposed automated method has adequate analytical sensitivity and selectivity for determination of IFN α(2a) in plasma samples for therapeutic drug monitoring. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Determination of residual volatile organic compounds migrated from polystyrene food packaging into food simulant by headspace solid phase micro extraction-gas chromatography

    International Nuclear Information System (INIS)

    Mohd Marsin Sanagi; Ling, Susie Lu; Zalilah Nasir; Wan Aini Wan Ibrahim; Abu Naim, Ahmedy

    2008-01-01

    The residual styrene and other volatile organic compounds (VOCs) present in the polystyrene food packaging are of concern as these compounds have the potential to migrate into the food in contact. This work describes a method for quantitative determination of VOCs, namely styrene, toluene, ethyl benzene, iso-propylbenzene and n-propylbenzene that have migrated from polystyrene food packaging into food stimulant by gas chromatography-flame ionization detection (GC-FID). Headspace solid phase micro extraction (HS-SPME) technique was applied for migration test using water as food stimulant. The effects of extraction variables including sample volume, eluotropic strength, extraction temperature, extraction time, desorption time, sample agitation, and salt addition on the amounts of the extracted analyses were studied to obtain the optimal HS-SPME conditions. The optimized method was applied to test the VOCs migrated from polystyrene bowls and cups at storage temperatures ranging from 24 to 80 degree Celsius for 30 min. Styrene and ethyl benzene were found to migrate from the samples into the food stimulant. The migration of analyze was found to be strongly dependent upon the storage temperature. The HS-SPME is useful as an alternative method to determine the migration of VOCs from food packaging material into food stimulant. (author)

  13. Preparation of C18 composite solid-phase microextraction fiber and its application to the determination of organochlorine pesticides in water samples.

    Science.gov (United States)

    Li, Siyan; Lu, Chengwei; Zhu, Fang; Jiang, Ruifen; Ouyang, Gangfeng

    2015-05-11

    In this work, a C18 composite solid-phase microextraction (SPME) fiber was prepared with a new method and applied to the analysis of organochlorine pesticides (OCPs) in water sample. A stainless steel wire (o.d. 127 μm) was used as the substrate, and a mixture of the C18 particle (3.5 μm) and the 184 silicone was used as the coating material. During the process of fiber preparation, a section of capillary column was used to fix the mixture onto the stainless steel wire and to ensure the constant of coating thickness. The prepared fiber showed excellent thermal stability and solvent resistance. By coupling with gas chromatography-mass spectrometry (GC-MS), the fiber exhibited wide linearity (2-500 ng L(-1)) and good sensitivity for the determination of six OCPs in water samples, the OCPs tested included hexachlorobezene, trans-chlordane, cis-chlordane, o,p-DDT, p,p-DDT and mirex. Not only the extraction performance of the newly prepared fiber was more than seven times higher than those of commercial fibers, the limits of detections (LODs) (0.059-0.151 ng L(-1)) for OCPs achieved under optimized conditions were also lower than those of reported SPME methods. The fiber was successfully applied to the determination of OCPs in real water samples by using developed SPME-GC-MS method. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Preparation of molecularly imprinted solid-phase microextraction fiber for the selective removal and extraction of the antiviral drug abacavir in environmental and biological matrices

    Energy Technology Data Exchange (ETDEWEB)

    Terzopoulou, Zoi [Laboratory of Polymer Chemistry and Technology, Department of Chemistry, Aristotle University of Thessaloniki, GR-541 24, Thessaloniki (Greece); Papageorgiou, Myrsini [Laboratory of Environmental Pollution Control, Department of Chemistry, Aristotle University of Thessaloniki, GR–541 24, Thessaloniki (Greece); Kyzas, George Z.; Bikiaris, Dimitrios N. [Laboratory of Polymer Chemistry and Technology, Department of Chemistry, Aristotle University of Thessaloniki, GR-541 24, Thessaloniki (Greece); Lambropoulou, Dimitra A., E-mail: dlambro@chem.auth.gr [Laboratory of Environmental Pollution Control, Department of Chemistry, Aristotle University of Thessaloniki, GR–541 24, Thessaloniki (Greece)

    2016-03-24

    In the present study, a molecularly imprinted solid-phase microextraction fiber (MIP-SPME{sub f}) was synthesized and applied for the selective removal and extraction of the antiviral drug, abacavir (ABA). Morphology and structure characterization of fibers were performed by scanning electron microscopy and Fourier transform infrared spectra, respectively. The effects on the adsorption behavior of the process parameters were studied and the equilibrium data were fitted by the Langmuir, Freundlich and Langmuir-Freundlich models. The maximum adsorption capability (Q{sub max}) was determined by Langmuir- Freundlich model and was 149 mg/g for MIP-SPME{sub f}. In the next step, SPME methodology followed by liquid desorption and liquid chromatography with mass spectrometry (LC/MS) has been developed and evaluated for the determination of the target compound in environmental and biological matrices (surface waters, wastewaters and urine). Parameters that could influence SPME efficiency were investigated. Then, optimization of stirring speed, extraction time and salt content was carried out by using a central composite design (CCD) and response surface methodology (RSM). A quadratic model between dependent and independent variables was built. Under the optimum conditions (extraction time 40 min, stirring rate 650 rpm and salt content 0.3% NaCl w/v) the validated method presented a high sensitivity and selectivity with LODs and LOQs in the range of 10.1–13.6 and 33.3–43.9 ng/L, respectively. The developed method was successfully applied to the analysis of ABA in real samples. The percentage extraction efficiency ranged from 88 to 99% revealing good accuracy and absence of matrix effects. - Highlights: • Preparation of a novel SPME MIP fiber with remarkable recognition properties. • Selective removal and extraction of abacavir from environmental & biological media. • Detailed adsorbent characterization and adsorption studies. • Successful application of

  15. Sol-gel-based SPME fiber as a reliable sampling technique for studying biogenic volatile organic compounds released from Clostridium tetani.

    Science.gov (United States)

    Ghader, Masoud; Shokoufi, Nader; Es-Haghi, Ali; Kargosha, Kazem

    2017-11-01

    A novel and efficient headspace solid-phase microextraction (HS-SPME) method, followed by gas chromatography mass spectrometry (GC-MS), was developed to study volatile organic compounds (VOCs) emerging from microorganisms. Two homemade SPME fibers, a semi-polar poly (dimethylsiloxane) (PDMS) fiber, and a polar polyethylene glycol (PEG) fiber, along with two commercial fibers (PDMS and PDMS/DVB) were used to collect VOCs emerging from Clostridium tetani which was cultured in different media. The adsorbed VOCs were desorbed and identified, in vitro, using GC-MS. The adsorption efficiency was improved by optimizing the time duration of adsorption and desorption. About 50 components were identified by the proposed method. The main detected compounds appeared to be sulfur containing compounds such as butanethioic acid S-methyl ester, dimethyl trisulfide, and dimethyl tetrasulfide. These volatile sulfur containing compounds are derived from amino acids containing the sulfur element, which probably coexist in the mentioned bacterium or are added to the culture media. The developed HS-SPME-GC-MS method allowed the determination of the chemical fingerprint of Clostridium tetani volatile constituents, and thus provides a new, simple, and reliable tool for studying the growth of microorganisms. Graphical abstract Investigation of biogenic VOCs released from Clostridium tetani using SPME-GC-MS.

  16. Comparison of two extraction techniques, solid-phase microextraction versus continuous liquid-liquid extraction/solvent-assisted flavor evaporation, for the analysis of flavor compounds in gueuze lambic beer.

    Science.gov (United States)

    Thompson-Witrick, Katherine A; Rouseff, Russell L; Cadawallader, Keith R; Duncan, Susan E; Eigel, William N; Tanko, James M; O'Keefe, Sean F

    2015-03-01

    Lambic is a beer style that undergoes spontaneous fermentation and is traditionally produced in the Payottenland region of Belgium, a valley on the Senne River west of Brussels. This region appears to have the perfect combination of airborne microorganisms required for lambic's spontaneous fermentation. Gueuze lambic is a substyle of lambic that is made by mixing young (approximately 1 year) and old (approximately 2 to 3 years) lambics with subsequent bottle conditioning. We compared 2 extraction techniques, solid-phase microextraction (SPME) and continuous liquid-liquid extraction/solvent-assisted flavor evaporation (CCLE/SAFE), for the isolation of volatile compounds in commercially produced gueuze lambic beer. Fifty-four volatile compounds were identified and could be divided into acids (14), alcohols (12), aldehydes (3), esters (20), phenols (3), and miscellaneous (2). SPME extracted a total of 40 volatile compounds, whereas CLLE/SAFE extracted 36 volatile compounds. CLLE/SAFE extracted a greater number of acids than SPME, whereas SPME was able to isolate a greater number of esters. Neither extraction technique proved to be clearly superior and both extraction methods can be utilized for the isolation of volatile compounds found in gueuze lambic beer. © 2015 Institute of Food Technologists®

  17. Characterization of the volatile profiles of beer using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Rossi, Serena; Sileoni, Valeria; Perretti, Giuseppe; Marconi, Ombretta

    2014-03-30

    The objective of this study was a multivariate characterization of the volatile profile of beers. Such a characterization is timely considering the increasing worldwide consumption of beer, the continuous growth of microbreweries and the importance of volatile compounds to beer flavour. A method employing solid-phase microextraction and gas chromatography-mass spectrometry (SPME-GC-MS) was optimized and then applied to a sample set of 36 industrial and craft beers of various styles and fermentation types. The volatile profiles of different beer styles is described, with particular attention paid to the volatile compounds characteristic of a spontaneously fermented lambic raspberry framboise beer. Furthermore, it was also possible to identify which specific volatile compounds are principally responsible for the differences in the volatile profiles of top- and bottom-fermented beers. Moreover, a volatile fingerprint of the craft top-fermented Italian beers was defined, as they show a very similar volatile profile. Finally, the volatile compounds that are characteristic of the bock-style beers are described. The SPME-GC-MS analytical method optimized in this study is suitable for characterizing the volatile fingerprint of different beers, especially on the basis of the kind of fermentation (top, bottom or spontaneous), the method of production and the style of the beer. © 2013 Society of Chemical Industry.

  18. Rapid Determination of Clenbuterol in Pork by Direct Immersion Solid-Phase Microextraction Coupled with Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Ye, Diru; Wu, Susu; Xu, Jianqiao; Jiang, Ruifen; Zhu, Fang; Ouyang, Gangfeng

    2016-02-01

    Direct immersion solid-phase microextraction (DI-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for rapid analysis of clenbuterol in pork for the first time. In this work, a low-cost homemade 44 µm polydimethylsiloxane (PDMS) SPME fiber was employed to extract clenbuterol in pork. After extraction, derivatization was performed by suspending the fiber in the headspace of the 2 mL sample vial saturated with a vapor of 100 µL hexamethyldisilazane. Lastly, the fiber was directly introduced to GC-MS for analysis. All parameters that influenced absorption (extraction time), derivatization (derivatization reagent, time and temperature) and desorption (desorption time) were optimized. Under optimized conditions, the method offered a wide linear range (10-1000 ng g(-1)) and a low detection limit (3.6 ng g(-1)). Finally, the method was successfully applied in the analysis of pork from the market, and recoveries of the method for spiked pork were 97.4-105.7%. Compared with the traditional solvent extraction method, the proposed method was much cheaper and fast. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Polyoxotungstate nanoclusters supported on silica as an efficient solid-phase microextraction fiber of polycyclic aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Abolghasemi, Mir Mahdi; Yousefi, Vahid; Rafiee, Ezzat

    2014-01-01

    A highly porous silica-supported tungstophosphoric acid (PW) nanocluster was prepared for use in solid-phase microextraction (SPME) of polycyclic aromatic hydrocarbons (PAHs). The PWs represent a class of discrete transition metal-oxide nanoclusters and their structures resemble discrete fragments of metal-oxide structures of definite size and shape. Transition metal-oxide nanoclusters display large structural diversity, and their monodisperse sizes can be tuned from several Ångstroms up to 10 nm. The highly porous silica-supported tungstophosphoric acid nanocluster material is found to be capable of efficiently extracting PAHs from aqueous sample solutions. The nanomaterial was immobilized on a stainless steel wire for fabrication of the SPME fiber. Following thermal desorption, the PAHs were quantified by GC-MS. Analytical merits include limits of detection that range from 0.02 to 0.1 pg mL −1 and a dynamic range as wide as from 0.001 to 100 ng mL −1 . Under optimum conditions, the repeatability for one fiber (n = 3), expressed as the relative standard deviation, is between 4.3 % and 8.6 %. The method is simple, rapid, and inexpensive. The thermal stability of the fiber and the high relative recovery make this method superior to conventional methods of extraction. (author)

  20. C12-Ag wire as solid-phase microextraction fiber for determination of benzophenone ultraviolet filters in river water.

    Science.gov (United States)

    Li, Jian; Ma, Liyun; Tang, Minqiong; Xu, Li

    2013-07-12

    In the present study, a novel approach for fabrication of solid-phase microextraction (SPME) fiber based on silver wire was proposed. 3-(Mercaptopropyl) trimethoxysilane (MPTS) was self-assembled on the silver wire by the special interaction between Ag and S, producing MPTS-Ag wire. The MPTS-Ag wire was then functionalized with dodecyltrimethoxysilane via sol-gel approach, giving C12-Ag wire. The preparation conditions were systematically optimized. The prepared fiber was then used as the SPME fiber to extract three benzophenone UV filters from the river water. The developed method showed good linearity between 0.005 and 0.200 μg mL(-1) with regression determination coefficients in the range of 0.9929-0.9988 and detection limits ranging from 0.58 to 1.86 ng mL(-1). The C12-Ag fiber exhibited good stability and long lifetime, and could be an alternative to the traditional fused silica fiber. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Screening of volatile composition of Lavandula hybrida Reverchon II honey using headspace solid-phase microextraction and ultrasonic solvent extraction.

    Science.gov (United States)

    Jerković, Igor; Marijanović, Zvonimir

    2009-03-01

    The volatiles of unifloral Lavandula hybrida Reverchon II honey were isolated by means of headspace solid-phase microextraction (HS-SPME) and ultrasonic solvent extraction (USE) and analyzed by gas chromatography and mass spectrometry (GC, GC/MS). A total of 23 compounds were identified in the headspace with hexan-1-ol, hexanal, acetic acid, hotrienol, and 2-phenylacetaldehyde as the principal components. Three solvents of different polarity were used for USE, and a total of 53 compounds were identified. The extracts with pentane/Et(2)O 1 : 2 (v/v) were the most representative for USE method containing the majority of the honey floral origin compounds and potential biomarkers (hexanol, acetic acid, butane-1,3-diol, butane-2,3-diol, benzoic acid, coumarin, and 2-phenylacetic acid). The total number of identified compounds (USE and HS-SPME) was 59. In general, the comparison with volatiles of other lavandin honeys of different geographic origins indicated several similarities, while acetic and formic acids were identified with high percentages in L. hybrida Reverchon II honey.

  2. Determination of Volatile Compounds in Four Commercial Samples of Japanese Green Algae Using Solid Phase Microextraction Gas Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Masayoshi Yamamoto

    2014-01-01

    Full Text Available Green algae are of great economic importance. Seaweed is consumed fresh or as seasoning in Japan. The commercial value is determined by quality, color, and flavor and is also strongly influenced by the production area. Our research, based on solid phase microextraction gas chromatography mass spectrometry (SPME-GC-MS, has revealed that volatile compounds differ intensely in the four varieties of commercial green algae. Accordingly, 41 major volatile compounds were identified. Heptadecene was the most abundant compound from Okayama (Ulva prolifera, Tokushima (Ulva prolifera, and Ehime prefecture (Ulva linza. Apocarotenoids, such as ionones, and their derivatives were prominent volatiles in algae from Okayama (Ulva prolifera and Tokushima prefecture (Ulva prolifera. Volatile, short chained apocarotenoids are among the most potent flavor components and contribute to the flavor of fresh, processed algae, and algae-based products. Benzaldehyde was predominant in seaweed from Shizuoka prefecture (Monostroma nitidum. Multivariant statistical analysis (PCA enabled simple discrimination of the samples based on their volatile profiles. This work shows the potential of SPME-GC-MS coupled with multivariant analysis to discriminate between samples of different geographical and botanical origins and form the basis for development of authentication methods of green algae products, including seasonings.

  3. Determination of volatile compounds in four commercial samples of Japanese green algae using solid phase microextraction gas chromatography mass spectrometry.

    Science.gov (United States)

    Yamamoto, Masayoshi; Baldermann, Susanne; Yoshikawa, Keisuke; Fujita, Akira; Mase, Nobuyuki; Watanabe, Naoharu

    2014-01-01

    Green algae are of great economic importance. Seaweed is consumed fresh or as seasoning in Japan. The commercial value is determined by quality, color, and flavor and is also strongly influenced by the production area. Our research, based on solid phase microextraction gas chromatography mass spectrometry (SPME-GC-MS), has revealed that volatile compounds differ intensely in the four varieties of commercial green algae. Accordingly, 41 major volatile compounds were identified. Heptadecene was the most abundant compound from Okayama (Ulva prolifera), Tokushima (Ulva prolifera), and Ehime prefecture (Ulva linza). Apocarotenoids, such as ionones, and their derivatives were prominent volatiles in algae from Okayama (Ulva prolifera) and Tokushima prefecture (Ulva prolifera). Volatile, short chained apocarotenoids are among the most potent flavor components and contribute to the flavor of fresh, processed algae, and algae-based products. Benzaldehyde was predominant in seaweed from Shizuoka prefecture (Monostroma nitidum). Multivariant statistical analysis (PCA) enabled simple discrimination of the samples based on their volatile profiles. This work shows the potential of SPME-GC-MS coupled with multivariant analysis to discriminate between samples of different geographical and botanical origins and form the basis for development of authentication methods of green algae products, including seasonings.

  4. Rapid Separation of Elemental Species by Fast Multicapillary Gas Chromatography with Multichannel Optical Spectrometry Detection following Headspace Solid Phase Microextraction

    Directory of Open Access Journals (Sweden)

    Jacek Giersz

    2015-05-01

    Full Text Available A method for conducting fast and efficient gas chromatography based on short multicapillaries in straight alignment combined with atomic emission detection was developed for field analysis. The strategy enables for speciation analysis of organometallic compounds. The analytes are simultaneously ethylated and preconcentrated on a solid phase microextraction (SPME fiber placed in the headspace over the sample for 25 min. The ethylated species are then completely separated and selectively quantified within 25 s under isothermal conditions. A new miniaturized speciation analyzer has been constructed and evaluated. The system consists of a GC injection port and a lab-made miniaturized GC unit directly coupled with miniaturized plasma excitation source. The emitted light is transferred via optical fiber and registered with a miniaturized charged coupled device (CCD based spectrometer. Working parameters for multicapillary column gas chromatography with atomic emission detector, including carrier gas flow rate, desorption temperature, and GC column temperature, were optimized to achieve good separation of analytes. Basic investigations of the fundamental properties of 5 cm-long multicapillary column, to evaluate its potential and limitations as a rapid separation unit, are presented. The adaptation of the technique for use with a SPME system and with a multichannel element-selective plasma-emission detector is highlighted.

  5. A salting out system for improving the efficiency of the headspace solid-phase microextraction of short and medium chain free fatty acids.

    Science.gov (United States)

    Fiorini, Dennis; Pacetti, Deborah; Gabbianelli, Rosita; Gabrielli, Serena; Ballini, Roberto

    2015-08-28

    Given the importance of short and medium chain free fatty acids (FFAs) in several fields, this study sought to improve the extraction efficiency of the solid-phase microextraction (SPME) of FFAs by evaluating salting out agents that appear promising for this application. The salts ammonium sulfate ((NH4)2SO4) and sodium dihydrogen phosphate (NaH2PO4) were tried on their own and in combination (3.7/1), in four different total amounts, as salting out agents in the headspace-SPME-gas chromatographic (HS-SPME-GC) analysis of the FFAs from acetic acid (C2) to decanoic acid (C10). Their performance in a model system of an aqueous standard mixture of FFAs at a pH of 3.5 was compared to that of the more commonly used sodium chloride (NaCl) and sodium sulfate (Na2SO4). All of the salts and salt systems evaluated, in proper amount, gave improved results compared to NaCl (saturated), which instead gave interesting results only for the least volatile FFAs C8 and C10. For C2-C6, the salt system that gave the best results compared to NaCl was (NH4)2SO4/NaH2PO4, in the highest of the four amounts evaluated, with factor increases between 1.2 and 4.1-fold, and NaH2PO4, between 1.0 and 4.3-fold. The SPME extraction efficiency given by the mixture (NH4)2SO4/NaH2PO4 was also assessed on biological and food samples, confirming that overall it performed better than NaCl. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. In vitro evaluation of new biocompatible coatings for solid-phase microextraction: implications for drug analysis and in vivo sampling applications.

    Science.gov (United States)

    Vuckovic, Dajana; Shirey, Robert; Chen, Yong; Sidisky, Len; Aurand, Craig; Stenerson, Katherine; Pawliszyn, Janusz

    2009-04-13

    A new line of solid-phase microextraction (SPME) coatings suitable for use with liquid chromatography applications was recently developed to address the limitations of the currently available coatings. The proposed coatings were immobilized on the metal fiber core and consisted of a mixture of proprietary biocompatible binder and various types of coated silica (octadecyl, polar embedded and cyano) particles. The aim of this research was to perform in vitro assessment of these new SPME fibers in order to evaluate their suitability for drug analysis and in vivo SPME applications. The main parameters examined were extraction efficiency, solvent resistance, preconditioning, dependence of extraction kinetics on coating thickness, carryover, linear range and inter-fiber reproducibility. The performance of the proposed coatings was compared against commercial Carbowax-TPR (CW-TPR) coating, when applicable. The fibers were evaluated for the extraction of drugs of different classes (carbamazepine, propranolol, pseudoephedrine, ranitidine and diazepam) from plasma and urine. The analyses were performed using liquid chromatography-tandem mass spectrometry. The results show that the fibers perform very well for the extraction of biological fluids with no sample pre-treatment required and can also be used for in vivo sampling applications of flowing blood. A coating thickness of 45 microm was found to be a good compromise between extraction capacity and extraction kinetics. Due to the high extraction efficiency of these coatings, pre-equilibrium SPME with very short extraction times (2 min) can be employed to increase sample throughput. Inter-fiber reproducibility was drugs examined in plasma, which is a significant improvement over polypyrrole coatings reported in literature, and permits single fiber use for in vivo applications.

  7. Cobalt oxide nanoparticles as a novel high-efficiency fiber coating for solid phase microextraction of benzene, toluene, ethylbenzene and xylene from aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Gholivand, Mohammad Bagher, E-mail: MB.Gholivand@yahoo.com [Department of Analytical Chemistry, Faculty of Chemistry, Razi University, Kermanshah (Iran, Islamic Republic of); Shamsipur, Mojtaba; Shamizadeh, Mohammad [Department of Analytical Chemistry, Faculty of Chemistry, Razi University, Kermanshah (Iran, Islamic Republic of); Moradian, Rostam; Astinchap, Bandar [Physics Department, Faculty of Science, Razi University, Kermanshah (Iran, Islamic Republic of); Nano Technology Research Laboratory, Razi University, Kermanshah (Iran, Islamic Republic of)

    2014-04-01

    Highlights: • Co{sub 3}O{sub 4} nanoparticles were introduced as a novel SPME fiber coating. • The fiber was evaluated for the extraction of BTEX in combination with GC–MS. • The fiber showed extraction efficiencies better than a PDMS fiber toward BTEX. • The fiber was successfully applied to the determination of BTEX in real samples. - Abstract: In this work cobalt oxide nanoparticles were introduced for preparation of a novel solid phase microextraction (SPME) fiber coating. Chemical bath deposition (CBD) technique was used in order for synthesis and immobilization of the Co{sub 3}O{sub 4} nanomaterials on a Pt wire for fabrication of SPME fiber. The prepared cobalt oxide coating was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. The fiber was evaluated for the extraction of benzene, toluene, ethylbenzene and xylene (BTEX) in combination with GC–MS. A simplex optimization method was used to optimize the factors affecting the extraction efficiency. Under optimized conditions, the proposed fiber showed extraction efficiencies comparable to those of a commercial polydimethylsiloxane (PDMS) fiber toward the BTEX compounds. The repeatability of the fiber and its reproducibility, expressed as relative standard deviation (RSD), were lower than about 11%. No significant change was observed in the extraction efficiency of the new SPME fiber after over 50 extractions. The fiber was successfully applied to the determination of BTEX compounds in real samples. The proposed nanostructure cobalt oxide fiber is a promising alternative to the commercial fibers as it is robust, inexpensive and easily prepared.

  8. Development of a novel graphene/polyaniline electrodeposited coating for on-line in-tube solid phase microextraction of aldehydes in human exhaled breath condensate.

    Science.gov (United States)

    Li, Yu; Xu, Hui

    2015-05-22

    In this work, we introduced a novel graphene/polyaniline (G/PANI) electrodeposited coating for on-line in-tube solid phase microextraction (IT-SPME) for the first time. The G/PANI coating was prepared on the internal surface of stainless steel tube by a facile in-situ electrodeposition method. The morphology and formation of the composite coating were confirmed by scanning electronic microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). Some important experimental parameters that could affect the extraction and separation such as the coating thickness, internal diameter of tube, sampling flow rate as well as sample volume were optimized. The extraction performance of the IT-SPME coating was evaluated systematically. The coating exhibited enhanced mechanical stability, long lifespan, large specific surface area and good biocompatibility compared with polyaniline coating. The on-line IT-SPME method showed higher enrichment efficiency, faster analysis speed and higher automation level than off-line manual mode. Six aldehydes were determined simultaneously with low limits of detection of 0.02-0.04nmolL(-1) and good linearity (R(2)≥0.9920). The method has been applied successfully for the determination of aldehydes in human exhaled breath condensates with good recovery (70-120%) and satisfied reproducibility (relative standard deviation: 1.1-11.9%). This on-line IT-SPME method provides a promising approach for the determination of trace aldehydes with approving sensitivity in human exhaled breath condensates. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Analysis of Volatile Markers for Virgin Olive Oil Aroma Defects by SPME-GC/FID: Possible Sources of Incorrect Data.

    Science.gov (United States)

    Oliver-Pozo, Celia; Aparicio-Ruiz, Ramón; Romero, Inmaculada; García-González, Diego L

    2015-12-09

    The need to explain virgin olive oil (VOO) aroma descriptors by means of volatiles has raised interest in applying analytical techniques for trapping and quantitating volatiles. Static headspace sampling with solid phase microextraction (SPME) as trapping material is one of the most applied solutions for analyzing volatiles. The use of an internal standard and the determination of the response factors of the main volatiles seem to guarantee the correct determination of volatile concentrations in VOOs by SPME-GC/FID. This paper, however, shows that the competition phenomena between volatiles in their adsorption to the SPME fiber, inherent in static headspace sampling, may affect the quantitation. These phenomena are more noticeable in the particular case of highly odorant matrices, such as rancid and vinegary VOOs with high intensity of defect. The competition phenomena can modify the measurement sensitivity, which can be observed in volatile quantitation as well as in the recording of internal standard areas in different matrices. This paper analyzes the bias of the peak areas and concentrations of those volatiles that are markers for each sensory defect of VOOs (rancid, vinegary, musty, and fusty) when the intensity and complexity of aroma are increased. Of the 17 volatile markers studied in this work, 10 presented some anomalies in the quantitation in highly odorant matrices due the competition phenomena. However, quantitation was not affected in the concentration ranges at which each volatile marker is typically found in the defective oils they were characteristic of, validating their use as markers.

  10. Essential oil from Rhaponticum acaule L. roots: Comparative study using HS-SPME/GC/GC–MS and hydrodistillation techniques

    Directory of Open Access Journals (Sweden)

    Batoul Benyelles

    2014-12-01

    Full Text Available The composition of essential oil extracted from Rhaponticum acaule L. roots growing wild in Algeria was studied by hydrodistillation (HD and by Head-Space Solid Phase Micro-Extraction (HS-SPME. Quantitative but not qualitative differences have been found in the chemical composition of both analysed samples depending on the extraction method. However, the oil obtained from R. acaule roots shows that aliphatic alcohols were found to be the major class (69.2%, followed by the terpenes (5.5%, alkenes (5.2% and alkynes (4.0%. In both cases the analysis were carried out using Gas Chromatography (GC and Gas Chromatography–Mass Spectrometry (GC–MS. Our study shows that HS-SPME extraction could be considered as an alternative technique for the isolation of volatiles from plant. 25 components were identified in oil vs. 39 in the HS-SPME. However the oil composition of roots was mainly represented by a variety of aliphatic hydrocarbons (alcohols, aldehydes and ketones and terpenes which are known for their antimicrobial activities.

  11. Development of a Direct Headspace Collection Method from Arabidopsis Seedlings Using HS-SPME-GC-TOF-MS Analysis

    Directory of Open Access Journals (Sweden)

    Kazuki Saito

    2013-04-01

    Full Text Available Plants produce various volatile organic compounds (VOCs, which are thought to be a crucial factor in their interactions with harmful insects, plants and animals. Composition of VOCs may differ when plants are grown under different nutrient conditions, i.e., macronutrient-deficient conditions. However, in plants, relationships between macronutrient assimilation and VOC composition remain unclear. In order to identify the kinds of VOCs that can be emitted when plants are grown under various environmental conditions, we established a conventional method for VOC profiling in Arabidopsis thaliana (Arabidopsis involving headspace-solid-phase microextraction-gas chromatography-time-of-flight-mass spectrometry (HS-SPME-GC-TOF-MS. We grew Arabidopsis seedlings in an HS vial to directly perform HS analysis. To maximize the analytical performance of VOCs, we optimized the extraction method and the analytical conditions of HP-SPME-GC-TOF-MS. Using the optimized method, we conducted VOC profiling of Arabidopsis seedlings, which were grown under two different nutrition conditions, nutrition-rich and nutrition-deficient conditions. The VOC profiles clearly showed a distinct pattern with respect to each condition. This study suggests that HS-SPME-GC-TOF-MS analysis has immense potential to detect changes in the levels of VOCs in not only Arabidopsis, but other plants grown under various environmental conditions.

  12. Analysis of organic micropollutants in drinking water using SPME and GC-MS

    International Nuclear Information System (INIS)

    Guidotti, M.; Ravaioli, G.

    1999-01-01

    In this work the purpose was to develop accurate and reproducible methods for the qualitative and quantitative analysis of pesticides/herbicides, phthalates, chlorinated solvents, trihalomethanes, polycyclic aromatic hydrocarbons (PAHs) and chlorophenols in drinking waters, using solid-phase micro extraction and GC-MS techniques. The SPME developed by J. Pawliszyn and co-workers, consists of an fused silica fibre, coated with an appropriate absorbent phase, hosted inside the needle of a holder that looks like a GC-syringe; the needle pierces the septum of a sealed vial and the fibre is lowered, by depressing the plunger of the holder, into the liquid (or in the headspace, if that is the case) that contains the analytes of interest. After a set period of time, necessary to reach the partitioning equilibrium, the fibre is retracted inside the needle, the needle is inserted into the GC injector port and the fibre pushed in the heated injector. Here the compounds of interest (that have adsorbed onto the fibre) are thermally desorbed and analysed by GC-MS. After three minutes the fibre is extracted and is ready for a new analysis. The SPME technique has already found many applications in food and environmental analysis. Many of the analytes investigated in this research are listed Italian legislation as possible pollutants of drinking waters and their presence and concentrations require monitoring. The list of compounds included in this work is reported in Table 1

  13. SPME-Based Ca-History Method for Measuring SVOC Diffusion Coefficients in Clothing Material.

    Science.gov (United States)

    Cao, Jianping; Liu, Ningrui; Zhang, Yinping

    2017-08-15

    Clothes play an important role in dermal exposure to indoor semivolatile organic compounds (SVOCs). The diffusion coefficient of SVOCs in clothing material (D m ) is essential for estimating SVOC sorption by clothing material and subsequent dermal exposure to SVOCs. However, few studies have reported the measured D m for clothing materials. In this paper, we present the solid-phase microextraction (SPME) based C a -history method. To the best of our knowledge, this is the first try to measure D m with known relative standard deviation (RSD). A thin sealed chamber is formed by a circular ring and two pieces of flat SVOC source materials that are tightly covered by the targeted clothing materials. D m is obtained by applying an SVOC mass transfer model in the chamber to the history of gas-phase SVOC concentrations (C a ) in the chamber measured by SPME. D m 's of three SVOCs, di-iso-butyl phthalate (DiBP), di-n-butyl phthalate (DnBP), and tris(1-chloro-2-propyl) phosphate (TCPP), in a cotton T-shirt can be obtained within 16 days, with RSD less than 3%. This study should prove useful for measuring SVOC D m in various sink materials. Further studies are expected to facilitate application of this method and investigate the effects of temperature, relative humidity, and clothing material on D m .

  14. Headspace solid phase microextraction (HSSPME) for the determination of volatile and semivolatile pollutants in soils

    Energy Technology Data Exchange (ETDEWEB)

    Llompart, Maria [Departamento de Quimica Analitica Nutricion y Bromatologia, Facultad de Quimica, Universidad de Santiago de Compostela, E-15706 Santiago de Compostela (Spain); Li, Ken; Fingas, Merv [Emergencies Science Division, Environment Canada, Environmental Technology Centre, 3439 River Road, Ottawa, ON (Canada)

    1999-02-08

    We have investigated the use of headspace solid phase microextraction (HSSPME) as a sample concentration and preparation technique for the analysis of volatile and semivolatile pollutants in soil samples. Soil samples were suspended in solvent and the SPME fibre suspended in the headspace above the slurry. Finally, the fibre was desorbed in the Gas Chromatograph (GC) injection port and the analysis of the samples was carried out. Since the transfer of contaminants from the soil to the SPME fibre involves four separate phases (soil-solvent-headspace and fibre coating), parameters affecting the distribution of the analytes were investigated. Using a well-aged artificially spiked garden soil, different solvents (both organic and aqueous) were used to enhance the release of the contaminants from the solid matrix to the headspace. It was found that simple addition of water is adequate for the purpose of analysing the target volatile organic chemicals (VOCs) in soil. The addition of 1 ml of water to 1 g of soil yielded maximum response. Without water addition, the target VOCs were almost not released from the matrix and a poor response was observed. The effect of headspace volume on response as well as the addition of salt were also investigated. Comparison studies between conventional static headspace (HS) at high temperature (95C) and the new technology HSSPME at room temperature (=20C) were performed. The results obtained with both techniques were in good agreement. HSSPME precision and linearity were found to be better than automated headspace method and HSSPME also produced a significant enhancement in response. The detection and quantification limits for the target VOCs in soils were in the sub-ng g{sup -1} level. Finally, we tried to extend the applicability of the method to the analysis of semivolatiles. For these studies, two natural soils contaminated with diesel fuel and wood preservative, as well as a standard urban dust contaminated with polyaromatic

  15. Determination of some volatile compounds in alcoholic beverage by headspace solid-phase microextraction gas chromatography - mass spectrometry

    Science.gov (United States)

    Schmutzer, G.; Avram, V.; Feher, I.; David, L.; Moldovan, Z.

    2012-02-01

    The volatile composition of alcoholic beverage was studied by headspace solid-phase microextraction (HSSPME) method and gas chromatography - mass spectrometry (GC-MS). Some volatile compounds, such as alcohols, esters, terpenes and other are mainly responsible for the flavor of fortified wines and their amounts specify the quality of the alcoholic beverages. From this perspective it is interesting to develop a rapid, selective and sensitive analytical method suitable for simultaneous quantification of the main molecules being responsible for the organoleptic characteristic of alcoholic beverages. Vermouth fortified drink was analyzed in order to characterize the volatile profile. Using the HS-SPME/GC-MS a number of twenty-six volatile compounds from a commercial market alcoholic beverage were identified. The most abundant compounds were m-thymol, o-thymol and eugenol, alongside of the ethyl ester compounds.

  16. In situ growth of IRMOF-3 combined with ionic liquids to prepare solid-phase microextraction fibers.

    Science.gov (United States)

    Zheng, Juan; Li, Siyan; Wang, Ying; Li, Lei; Su, Chengyong; Liu, Hong; Zhu, Fang; Jiang, Ruifen; Ouyang, Gangfeng

    2014-06-04

    A superior solid-phase microextraction (SPME) fiber-coating material, IRMOF-3@ILs/PDMS, was prepared by the in situ growth of IRMOF-3 onto stainless-steel wires and protection with ionic liquids (ILs) and polydimethylsiloxane (PDMS). The ILs can efficiently prevent the substantial cracking of IRMOF-3 caused by moisture, and a thin PDMS film can protect the IRMOF-3@ILs material to achieve a much better extraction efficiency as well as excellent resistance to high temperature and high humidity. This IRMOF-3@ILs/PDMS coating possessed a porous structure, a rough surface and an increased lifespan (by at least 100 times) compared with that of IRMOF-3. The coating was evaluated by analyzing four polycyclic aromatic hydrocarbons (PAHs) in water, and good precision (analysis of PAHs in rainwater by coupling it with gas chromatography-mass spectrometry (GC-MS). Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Selective molecularly imprinted polymer combined with restricted access material for in-tube SPME/UHPLC-MS/MS of parabens in breast milk samples

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Israel D.; Melo, Lidervan P. [Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Jardim, Isabel C.S.F. [Instituto de Química, Universidade Estadual de Campinas, Campinas, SP (Brazil); Monteiro, Juliana C.S.; Nakano, Ana Marcia S. [Escola de Enfermagem de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Queiroz, Maria Eugênia C., E-mail: mariaeqn@ffclrp.usp.br [Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2016-08-17

    A new molecularly imprinted polymer modified with restricted access material (a hydrophilic external layer), (MIP-RAM) was synthesized via polymerization in situ in an open fused silica capillary. This stationary phase was used as sorbent for in-tube solid phase microextraction (in-tube SPME) to determine parabens in breast milk samples by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Scanning electron micrographs (SEM) illustrate MIP surface modification after glycerol dimethacrylate (hydrophilic monomer) incorporation. The interaction between parabens and MIP-RAM was investigated by Fourier-transform infrared (FTIR) spectroscopy. The Scatchard plot for MIP-RAM presented two linear parts with different slopes, illustrating binding sites with high- and low-affinity. Endogenous compounds exclusion from the MIP-RAM capillary was demonstrated by in-tube SPME/LC-UV assays carried out with blank milk samples. The in-tube SPME/UHPLC-MS/MS method presented linear range from 10 ng mL{sup −1} (LLOQ) to 400 ng mL{sup −1} with coefficients of determination higher than 0.99, inter-assay precision with coefficient of variation (CV) values ranging from 2 to 15%, and inter-assay accuracy with relative standard deviation (RSD) values ranging from −1% to 19%. Analytical validation parameters attested that in-tube SPME/UHPLC-MS/MS is an appropriate method to determine parabens in human milk samples to assess human exposure to these compounds. Analysis of breast milk samples from lactating women demonstrated that the proposed method is effective. - Highlights: • Molecularly imprinted polymer modified with a hydrophilic external layer (RAM-MIP) was synthesized in a silica capillary. • RAM-MIP capillary, used as sorbent for in-tube SPME, established specific interaction with parabens present in milk samples. • The matrix components that interacted only with the hydrophilic external layer (non-adsorptive network) were excluded.

  18. Rapid sampling of BTEX in air by SPME in the city of Nice and at the Nice-Cote d'Azur airport; Echantillonnage rapide des BTEX dans l'air par SPME dans la ville de Nice et a l'aeroport Nice-Cote d'Azur

    Energy Technology Data Exchange (ETDEWEB)

    Tumbiolo, S.; Gal, J.F.; Maria, P.Ch. [Nice Univ. Sophia Antipolis, Lab. de Radiochimie, Sciences Analytique et Environnement, Faculte des Sciences, 06 (France); Laborde, P.; Teton, S. [Qualitair, Nice Leader, 06 - Nice (France)

    2006-04-15

    This article presents the results of a tentative application of Solid Phase Micro Extraction (SPME) to the analysis of BTEX (benzene, toluene, ethyl-benzene and xylenes) at the {mu}g/m{sup 3} level in indoor and outdoor air. The salient features of the method validation are reported. Sampling by QUALITAIR using Radiello passive samplers, was carried out from 2001 to 2004 in the city of Nice and its airport. Urban traffic impact was proved, but a link between BTX concentrations and the variations of airport activities was not clearly established. During the same period, several samplings were performed using SPME. Taking into account the short (30 minutes) sampling time, rapid changes of BTEX concentrations were evidenced, as for example the start of airplane engines. As field studies have shown, SPME technique appears as a method of choice for fast qualitative analysis and quantitative determination of Volatile Organic Compounds (VOC). The small dimensions of the SPME sampling system and the short sampling time let envisage its utilisation for the rapid diagnostic and the monitoring of indoor air quality. (author)

  19. Ion-pair in-tube solid-phase microextraction and capillary liquid chromatography using a titania-based column: application to the specific lauralkonium chloride determination in water.

    Science.gov (United States)

    Prieto-Blanco, M C; Moliner-Martínez, Y; López-Mahía, P; Campíns-Falcó, P

    2012-07-27

    A quick, miniaturized and on-line method has been developed for the determination in water of the predominant homologue of benzalkonium chloride, dodecyl dimethyl benzyl ammonium chloride or lauralkonium chloride (C(12)-BAK). The method is based on the formation of an ion-pair in both in-tube solid-phase microextraction (IT-SPME) and capillary liquid chromatography. The IT-SPME optimization required the study of the length and nature of the stationary phase of capillary and the processed sample volume. Because to the surfactant character of the analyte both, the extracting and replacing solvents, have played a decisive role in the IT-SPME optimized procedure. Conditioning the capillary with the mobile phase which contains the counter ion (acetate), using an organic additive (tetrabutylammonium chloride) added to the sample and a mixture water/methanol as replacing solvent (processed just before the valve is switched to the inject position), allowed to obtain good precision of the retention time and a narrow peak for C(12)-BAK. A reversed-phase capillary based TiO(2) column and a mobile phase containing ammonium acetate at pH 5.0 for controlling the interactions of cationic surfactant with titania surface were proposed. The optimized procedure provided adequate linearity, accuracy and precision at the concentrations interval of 1.5-300 μg L(-1) .The limit of detection (LOD) was 0.5 μg L(-1) using diode array detection (DAD). The applicability of proposed IT-SPME-capillary LC method has been assessed in several water samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. MQ NMR and SPME analysis of nonlinearity in the degradation of a filled silicone elastomer

    Energy Technology Data Exchange (ETDEWEB)

    Chinn, S C; Alviso, C T; Berman, E S; Harvey, C A; Maxwell, R S; Wilson, T S; Cohenour, R; Saalwachter, K; Chasse, W

    2008-10-10

    Radiation induced degradation of polymeric materials occurs via numerous, simultaneous, competing chemical reactions. Though degradation is typically found to be linear in adsorbed dose, some silicone materials exhibit non-linear dose dependence due to dose dependent dominant degradation pathways. We have characterized the effects of radiative and thermal degradation on a model filled-PDMS system, Sylgard 184 (commonly used as an electronic encapsulant and in biomedical applications), using traditional mechanical testing, NMR spectroscopy, and sample headspace analysis using Solid Phase Micro-Extraction (SPME) followed by Gas Chromatography/Mass Spectrometry (GC/MS). The mechanical data and {sup 1}H spin-echo NMR indicated that radiation exposure leads to predominantly crosslinking over the cumulative dose range studies (0 to 250 kGray) with a rate roughly linear with dose. {sup 1}H Multiple Quantum NMR detected a bimodal distribution in the network structure, as expected by the proposed structure of Sylgard 184. The MQ-NMR further indicated that the radiation induced structural changes were not linear in adsorbed dose and competing chain scission mechanisms contribute more largely to the overall degradation process in the range of 50 -100 kGray (though crosslinking still dominates). The SPME-GC/MS data were analyzed using Principal Component Analysis (PCA), which identified subtle changes in the distributions of degradation products (the cyclic siloxanes and other components of the material) as a function of age that provide insight into the dominant degradation pathways at low and high adsorbed dose.

  1. Quantification of Polyfunctional Thiols in Wine by HS-SPME-GC-MS Following Extractive Alkylation.

    Science.gov (United States)

    Musumeci, Lauren E; Ryona, Imelda; Pan, Bruce S; Loscos, Natalia; Feng, Hui; Cleary, Michael T; Sacks, Gavin L

    2015-07-06

    Analyses of key odorous polyfunctional volatile thiols in wines (3-mercaptohexanol (3-MH), 3-mercaptohexylacetate (3-MHA), and 4-mercapto-4-methyl-2-pentanone (4-MMP)) are challenging due to their high reactivity and ultra-trace concentrations, especially when using conventional gas-chromatography electron impact mass spectrometry (GC-EI-MS). We describe a method in which thiols are converted to pentafluorobenzyl (PFB) derivatives by extractive alkylation and the organic layer is evaporated prior to headspace solid phase microextraction (HS-SPME) and GC-EI-MS analysis. Optimal parameters were determined by response surface area modeling. The addition of NaCl solution to the dried SPME vials prior to extraction resulted in up to less than fivefold improvement in detection limits. Using 40 mL wine samples, limits of detection for 4-MMP, 3-MH, and 3-MHA were 0.9 ng/L, 1 ng/L, and 17 ng/L, respectively. Good recovery (90%-109%) and precision (5%-11% RSD) were achieved in wine matrices. The new method was used to survey polyfunctional thiol concentrations in 61 commercial California and New York State wines produced from V. vinifera (Riesling, Gewürztraminer, Cabernet Sauvignon, Sauvignon blanc and non-varietal rosé wines), V. labruscana (Niagara), and Vitis spp. (Cayuga White). Mean 4-MMP concentrations in New York Niagara (17 ng/L) were not significantly different from concentrations in Sauvignon blanc, but were significantly higher than 4-MMP in other varietal wines.

  2. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    International Nuclear Information System (INIS)

    Ameli, Akram; Alizadeh, Naader

    2011-01-01

    Highlights: ► Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. ► This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. ► Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 × 10 −8 to 5 × 10 −4 and 1.2 × 10 −6 to 5 × 10 −4 mol mL −1 and the detection limit was 4 × 10 −8 mol L −1 . The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  3. SOLID-PHASE PEPTIDE SYNTHESIS OF ISOTOCIN WITH AMIDE ...

    African Journals Online (AJOL)

    SOLID-PHASE PEPTIDE SYNTHESIS OF ISOTOCIN WITH AMIDE OF ASPARAGINE PROTECTED WITH 1-TETRALINYL. TRIFLUOROMETHANESULPHONIC ACID (TFMSA) DEPROTECTION, CLEAVAGE AND AIR OXIDATION OF MERCAPTO GROUPS TO DISULPHIDE.

  4. Solid-Solid Vacuum Regolith Heat-Exchanger for Oxygen Production, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase-1 project will demonstrate the feasibility of using a novel coaxial counterflow solid-solid heat exchanger to recover heat energy from spent regolith...

  5. Comparison of the atmospheric- and reduced-pressure HS-SPME strategies for analysis of residual solvents in commercial antibiotics using a steel fiber coated with a multiwalled carbon nanotube/polyaniline nanocomposite.

    Science.gov (United States)

    Ghiasvand, Ali Reza; Nouriasl, Kolsoum; Yazdankhah, Fatemeh

    2018-01-01

    A low-cost, sensitive and reliable reduced-pressure headspace solid-phase microextraction (HS-SPME) setup was developed and evaluated for direct extraction of residual solvents in commercial antibiotics, followed by determination by gas chromatography with flame ionization detection (GC-FID). A stainless steel narrow wire was made porous and adhesive by platinization by a modified electrophoretic deposition method and coated with a polyaniline/multiwalled carbon nanotube nanocomposite. All experimental variables affecting the extraction efficiency were investigated for both atmospheric-pressure and reduced-pressure conditions. Comparison of the optimal experimental conditions and the results demonstrated that the reduced-pressure strategy leads to a remarkable increase in the extraction efficiency and reduction of the extraction time and temperature (10 min, 25 °Ϲ vs 20 min, 40 °Ϲ). Additionally, the reduced-pressure strategy showed better analytical performances compared with those obtained by the conventional HS-SPME-GC-FID method. Limit of detections, linear dynamic ranges, and relative standard deviations of the reduced-pressure HS-SPME procedure for benzene, toluene, ethylbenzene, and xylene (BTEX) in injectable solid drugs were obtained over the ranges of 20-100 pg g -1 , 0.02-40 μg g -1 , and 2.8-10.2%, respectively. The procedure developed was successful for the analysis of BTEX in commercial containers of penicillin, ampicillin, ceftriaxone, and cefazolin. Graphical abstract Schematic representation of the developed RP-HS-SPME setup.

  6. Determination of 8 Synthetic Food Dyes by Solid Phase Extraction ...

    African Journals Online (AJOL)

    aminopropyl-modified silica SPE cartridge, and thereafter determined by reverse phase high ... Keywords: Synthetic colors, Food, Fruit flavored drinks, Solid phase extraction, RP-HPLC ..... by thin-layer chromatography-fast atom bombardment.

  7. Fast and robust direct immersion solid phase microextraction coupled with gas chromatography-time-of-flight mass spectrometry method employing a matrix compatible fiber for determination of triazole fungicides in fruits.

    Science.gov (United States)

    Silva, Érica A Souza; Lopez-Avila, Viorica; Pawliszyn, Janusz

    2013-10-25

    A fast and robust method was developed for the determination of ten triazole fungicides in fruit samples using direct immersion solid-phase microextraction coupled to gas chromatography with time-of-flight mass spectrometry detection (DI-SPME-GC-ToFMS). In this work, a newly developed concept of solid-phase microextraction (SPME) sorbent, which allows for direct immersion extraction in complex food matrices, has been applied in the analysis of 10 triazole fungicides in grapes and strawberries pulps. Potential factors affecting the extraction efficiency were investigated and optimized, including extraction temperature, sample pH, and ionic strength, agitation speed, extraction and desorption times. Under optimized conditions, the method was linear for over 4 orders of magnitude in concentration, with linear regression coefficients (R(2)) greater than 0.99 for all test compounds in both matrices. Method reproducibility, as determined by analysis of spiked grapes and strawberries, was better than ±20%. The limits of quantitation objective (LOQs) ranged from 0.25 to 5 ng g(-1) for both matrices, well below the maximum residues levels allowed for those compounds in both matrices. The method was successfully applied in the analysis of commercial samples of grapes and strawberries. Finally, the new SPME method was compared to a modified version of t QuEChERS AOAC method: the limits of quantitation reached by SPME were at least one order of magnitude lower than those achieved by the QuEChERS method, whereas precision and accuracy were comparable for both methods. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Study of aged cognac using solid-phase microextraction and partial least-squares regression.

    Science.gov (United States)

    Watts, Vivian A; Butzke, Christian E; Boulton, Roger B

    2003-12-17

    Headspace solid-phase microextraction (SPME) and GC-MS were used to analyze 17 commercial French Cognac brandies (9 young and 8 well-aged, ranging in age from 3 to 55 years). Sixty-four volatiles were chosen on the basis of chromatographic separation and/or known odor importance. Chromatographic peaks were manually integrated and the peak area data analyzed using partial least-squares (PLS) regression to study relationships between volatile composition (X variables) and age (Y variable). When only those compounds with the highest significance were included and from these selected the variables (a total of 33) with the highest correlation loadings on the first two principal components, principal component 1 explained 82% of the variance of the measured compounds and 85% of the variance in age. These were considered the most important volatiles to distinguish products of different ages because young and old samples were separated along principal component 1. Norisoprenoids, terpenes, and acetate esters had weaker positive and negative loadings and were therefore left out. The PLS model could predict sample age accurately with the optimum 33 volatiles as well as with a smaller subset consisting of ethyl esters and methyl ketones.

  9. Application of solid-phase microextraction for determining phenylurea herbicides and their homologous anilines from vegetables.

    Science.gov (United States)

    Berrada, H; Font, G; Moltó, J C

    2004-07-09

    Residues of metobromuron, monolinuron and linuron herbicides and their aniline homologous were analyzed in carrots, onions and potatoes by solid-phase microextraction (SPME) performed with a polyacrylate fiber. A juice was obtained from food samples that were further diluted, and an aliquot was extracted after sodium chloride (14%) addition and pH control. At pH 4 only the phenylureas were extracted. A new extraction at pH 11 allowed the extraction of phenylureas plus homologous aniline metabolites. Determination was carried out by gas chromatography with nitrogen-phosporus detection (NPD) the identity of the determined compounds was studied by gas chromatography-mass spectrometry. Limits of quantification (LOQs) obtained with NPD and MS (selected-ion monitoring) were in the microg/kg order allowing determination of maximum residue levels (MRLs) established in the Spanish regulations. MRLs ranged from 0.02 to 0.1 mg/kg depending on the kind of food and herbicide. Under the proposed conditions matrix effects were low enough to permit calibration with samples proceeding from ecological (non-pesticide treated) crops. Twelve commercial samples of each carrots, onions and potatoes were analyzed and only three samples of potatoes contained residues of linuron at levels below MRLs.

  10. Zinc oxide/polypyrrole nanocomposite as a novel solid phase microextraction coating for extraction of aliphatic hydrocarbons from water and soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Amanzadeh, Hatam; Yamini, Yadollah [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175 Tehran (Iran, Islamic Republic of); Moradi, Morteza [Department of Semiconductors, Materials and Energy Research Center, Karaj (Iran, Islamic Republic of)

    2015-07-16

    Highlights: • ZnO/polypyrrole (ZNO/PPY) nanocomposite coating was fabricated on stainless steel. • Nanocomposite coating morphology was evaluated using scanning electron microscopy. • It was applied for HS-SPME of aliphatic hydrocarbons in water and soil samples. • Separation and determination of the hydrocarbons were performed by GC-FID. • The method is suitable for routine analysis of n-alkanes in various environmental samples. - Abstract: In this work, ZnO/PPy nanocomposite coating was fabricated on stainless steel and evaluated as a novel headspace solid phase microextraction (HS-SPME) fiber coating for extraction of ultra-trace amounts of environmental pollutants; namely, aliphatic hydrocarbons in water and soil samples. The ZnO/PPy nanocomposite were prepared by a two-step process including the electrochemical deposition of PPy on the surface of stainless steel in the first step, and the synthesis of ZnO nanorods by hydrothermal process in the pores of PPy matrix in the second step. Porous structure together with ZnO nanorods with the average diameter of 70 nm were observed on the surface by using scanning electron microscopy (SEM). The effective parameters on HS-SPME of hydrocarbons (i.e., extraction temperature, extraction time, desorption temperature, desorption time, salt concentration, and stirring rate) were investigated and optimized by one-variable-at-a-time method. Under optimized conditions (extraction temperature, 65 ± 1 °C; extraction time, 15 min; desorption temperature, 250 °C; desorption time, 3 min; salt concentration, 10% w/v; and stirring rate, 1200 rpm), the limits of detection (LODs) were found in the range of 0.08–0.5 μg L{sup −1}, whereas the repeatability and fiber-to-fiber reproducibility were in the range 5.4–7.6% and 8.6–10.4%, respectively. Also, the accuracies obtained for the spiked n-alkanes were in the range of 85–108%; indicating the absence of matrix effects in the proposed HS-SPME method. The results

  11. Development of an SPME-GC-MS/MS method for the determination of pesticides in rainwater: Laboratory and field experiments

    International Nuclear Information System (INIS)

    Sauret-Szczepanski, Nathalie; Mirabel, Philippe; Wortham, Henri

    2006-01-01

    A solid-phase microextraction - coupled to a gas chromatography - ion trap tandem mass spectrometry (SPME-GC-MS/MS) method was developed for the quantitative determination in rainwater of 8 pesticides amongst the most used in France and 3 triazines metabolites. The main factors affecting the SPME process were studied. Using a 3 mL sample, the method developed showed good linearity for concentrations ranging from 0.05 to 50 μg L -1 with correlation coefficients between 0.997 and 0.9999 and relative standard deviations (% RSD) below 14%. The study of matrix effects showed that rainwater was too diluted to have any significant influence on the extraction efficiency. To validate the method, a field campaign was carried out on the rain events, which occurred in Strasbourg during a one-year period. The rain concentrations showed patterns of high pesticide concentrations during spring months, which were correlated to the spraying periods of most of these substances. - Solid-phase microextraction efficiency of pesticides in rainwater was optimized

  12. Development of an SPME-GC-MS/MS method for the determination of pesticides in rainwater: Laboratory and field experiments

    Energy Technology Data Exchange (ETDEWEB)

    Sauret-Szczepanski, Nathalie [Equipe de Physico-chimie de l' Atmosphere, Centre de Geochimie de la Surface (UMR 7517) 1, rue Blessig, 67084 Strasbourg Cedex (France)]. E-mail: nathalie.sauret-szczepanski@alcan.com; Mirabel, Philippe [Equipe de Physico-chimie de l' Atmosphere, Centre de Geochimie de la Surface (UMR 7517) 1, rue Blessig, 67084 Strasbourg Cedex (France); Wortham, Henri [Universite de Provence, Laboratoire Chimie et Environnement, Case 29, 3 Place Victor Hugo, 13331 Marseille Cedex (France)]. E-mail: wortham@up.univ-mrs.fr

    2006-01-15

    A solid-phase microextraction - coupled to a gas chromatography - ion trap tandem mass spectrometry (SPME-GC-MS/MS) method was developed for the quantitative determination in rainwater of 8 pesticides amongst the most used in France and 3 triazines metabolites. The main factors affecting the SPME process were studied. Using a 3 mL sample, the method developed showed good linearity for concentrations ranging from 0.05 to 50 {mu}g L{sup -1} with correlation coefficients between 0.997 and 0.9999 and relative standard deviations (% RSD) below 14%. The study of matrix effects showed that rainwater was too diluted to have any significant influence on the extraction efficiency. To validate the method, a field campaign was carried out on the rain events, which occurred in Strasbourg during a one-year period. The rain concentrations showed patterns of high pesticide concentrations during spring months, which were correlated to the spraying periods of most of these substances. - Solid-phase microextraction efficiency of pesticides in rainwater was optimized.

  13. Optimization of the coating procedure for a high-throughput 96-blade solid phase microextraction system coupled with LC-MS/MS for analysis of complex samples.

    Science.gov (United States)

    Mirnaghi, Fatemeh S; Chen, Yong; Sidisky, Leonard M; Pawliszyn, Janusz

    2011-08-01

    Biocompatible C18-polyacrylonitrile (PAN) coating was used as the extraction phase for an automated 96-blade solid phase microextraction (SPME) system with thin-film geometry. Three different methods of coating preparation (dipping, brush painting, and spraying) were evaluated; the spraying method was optimum in terms of its stability and reusability. The high-throughput sample preparation was achieved by using a robotic autosampler that enabled simultaneous preparation of 96 samples in 96-well-plate format. The increased volume of the extraction phase of the C18-PAN thin film coating resulted in significant enhancement in the extraction recovery when compared with that of the C18-PAN rod fibers. Various factors, such as reusability, reproducibility, pH stability, and reliability of the coating were evaluated. The results showed that the C18-PAN 96-blade SPME coating presented good extraction recovery, long-term reusability, good reproducibility, and biocompatibility. The limits of detection and quantitation were in the ranges of 0.1-0.3 and 0.5-1 ng/mL for all four analytes.

  14. Study on the Solid Phase Extraction and Spectrophotometric ...

    African Journals Online (AJOL)

    NJD

    By solid phase extraction of the. Hg(II)-ABTR chelate with a C18 disk, an enrichment factor of 50 was achieved. Combining the new reagent with solid phase extraction allowed the development of a highly sensitive, selective and rapid method for the determination of mercury in water and biological samples. 2. Experimental.

  15. Solid-Phase Extraction Combined with High Performance Liquid ...

    African Journals Online (AJOL)

    Methods: Solid-phase extraction method was employed for the extraction of the estrogen from milk and ... Solid phase extraction is recognized as the most common sample pre- treatment technique to enhance the concentration of a target in biological samples. [17]. The aim ... pure water (solvent B) in HPLC experiment. The.

  16. Analysis of Mars Analogue Soil Samples Using Solid-Phase Microextraction, Organic Solvent Extraction and Gas Chromatography/Mass Spectrometry

    Science.gov (United States)

    Orzechowska, G. E.; Kidd, R. D.; Foing, B. H.; Kanik, I.; Stoker, C.; Ehrenfreund, P.

    2011-01-01

    Polycyclic aromatic hydrocarbons (PAHs) are robust and abundant molecules in extraterrestrial environments. They are found ubiquitously in the interstellar medium and have been identified in extracts of meteorites collected on Earth. PAHs are important target molecules for planetary exploration missions that investigate the organic inventory of planets, moons and small bodies. This study is part of an interdisciplinary preparation phase to search for organic molecules and life on Mars. We have investigated PAH compounds in desert soils to determine their composition, distribution and stability. Soil samples (Mars analogue soils) were collected at desert areas of Utah in the vicinity of the Mars Desert Research Station (MDRS), in the Arequipa region in Peru and from the Jutland region of Denmark. The aim of this study was to optimize the solid-phase microextraction (SPME) method for fast screening and determination of PAHs in soil samples. This method minimizes sample handling and preserves the chemical integrity of the sample. Complementary liquid extraction was used to obtain information on five- and six-ring PAH compounds. The measured concentrations of PAHs are, in general, very low, ranging from 1 to 60 ng g(sup -1). The texture of soils is mostly sandy loam with few samples being 100% silt. Collected soils are moderately basic with pH values of 8-9 except for the Salten Skov soil, which is slightly acidic. Although the diverse and variable microbial populations of the samples at the sample sites might have affected the levels and variety of PAHs detected, SPME appears to be a rapid, viable field sampling technique with implications for use on planetary missions.

  17. Solid-solid phase transitions in Fe nanowires induced by axial strain

    International Nuclear Information System (INIS)

    Sandoval, Luis; Urbassek, Herbert M

    2009-01-01

    By means of classical molecular-dynamics simulations we investigate the solid-solid phase transition from a bcc to a close-packed crystal structure in cylindrical iron nanowires, induced by axial strain. The interatomic potential employed has been shown to be capable of describing the martensite-austenite phase transition in iron. We study the stress versus strain curves for different temperatures and show that for a range of temperatures it is possible to induce a solid-solid phase transition by axial strain before the elasticity is lost; these transition temperatures are below the bulk transition temperature. The two phases have different (non-linear) elastic behavior: the bcc phase softens, while the close-packed phase stiffens with temperature. We also consider the reversibility of the transformation in the elastic regimes, and the role of the strain rate on the critical strain necessary for phase transition.

  18. Determination of aflatoxins in food samples by automated on-line in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Nonaka, Y; Saito, K; Hanioka, N; Narimatsu, S; Kataoka, H

    2009-05-15

    A simple and sensitive automated method for determination of aflatoxins (B1, B2, G1, and G2) in nuts, cereals, dried fruits, and spices was developed consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-mass spectrometry (LC-MS). Aflatoxins were separated within 8 min by high-performance liquid chromatography using a Zorbax Eclipse XDB-C8 column with methanol/acetonitrile (60/40, v/v): 5mM ammonium formate (45:55) as the mobile phase. Electrospray ionization conditions in the positive ion mode were optimized for MS detection of aflatoxins. The pseudo-molecular ions [M+H](+) were used to detect aflatoxins in selected ion monitoring (SIM) mode. The optimum in-tube SPME conditions were 25draw/eject cycles of 40 microL of sample using a Supel-Q PLOT capillary column as an extraction device. The extracted aflatoxins were readily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME LC-MS with SIM method, good linearity of the calibration curve (r>0.9994) was obtained in the concentration range of 0.05-2.0 ng/mL using aflatoxin M1 as an internal standard, and the detection limits (S/N=3) of aflatoxins were 2.1-2.8 pg/mL. The in-tube SPME method showed >23-fold higher sensitivity than the direct injection method (10 microL injection volume). The within-day and between-day precision (relative standard deviations) at the concentration of 1 ng/mL aflatoxin mixture were below 3.3% and 7.7% (n=5), respectively. This method was applied successfully to analysis of food samples without interference peaks. The recoveries of aflatoxins spiked into nuts and cereals were >80%, and the relative standard deviations were Aflatoxins were detected at <10 ng/g in several commercial food samples.

  19. JV Task 92 - Alcoa/Retec SFE and SPME

    Energy Technology Data Exchange (ETDEWEB)

    Steven Hawthorne

    2009-02-15

    This report summarizes the work performed by the Energy & Environmental Research Center (EERC) under the U.S. Department of Energy Jointly Sponsored Research Program JV Task 92, which is a continuation of JV9. Successful studies performed in 1999 through the end of 2008 demonstrated the potential for using selective supercritical fluid extraction (SFE) and a solid-phase microextraction (SPME) method for measuring sediment pore water polycyclic aromatic hydrocarbons (PAHs) to mimic the bioavailability of PAHs from manufactured gas plant and aluminum smelter soils and sediments both in freshwater and saltwater locations. The studies that the EERC has performed with the commercial partners have continued to generate increased interest in both the regulatory communities and in the industries that have historically produced or utilized coal tar products. Both ASTM International and the U.S. Environmental Protection Agency (EPA) have accepted the pore water method developed at the EERC as standard methods. The studies have demonstrated the effectiveness of our techniques in predicting bioavailability of PAHs from ca. 250 impacted and background field sediments and soils. The field demonstrations from the final years of the project continued to build the foundation data for acceptance of our methods by the regulatory communities. The JV92 studies provide the single largest database in the world that includes measures of PAH bioavailability along with biological end points. These studies clearly demonstrated that present regulatory paradigms based on equilibrium partitioning greatly overpredict bioavailability. These investigations also laid the foundation for present (non-JV) studies being applied to PAHs and polychlorinated biphenyls (PCBs) at EPA Superfund sites, investigations into PAH and PCB bioavailability at U.S Department of Defense sites, and the application of the techniques to investigating the bioavailability of chlorinated dioxins and furans from impacted

  20. Comparative Analyses of the Volatile Components of Citrus Aurantium L. Flowers Using Ultrasonic-Assisted Headspace SPME and Hydrodistillation Combined with GC-MS and Evaluation of their Antimicrobial Activities

    Directory of Open Access Journals (Sweden)

    Akram Rahimi

    2014-12-01

    Full Text Available The volatile components of Citrus aurantium L. flowers were characterized by GC-MS with two different extraction techniques, hydrodistillation (HD and ultrasonic-assisted headspace solid phase microextraction (UA-HS-SPME. In the SPME method, the volatile components of the samples, irradiated by ultrasonic radiation, were collected on a polydimethyl siloxane (PDMS commercial fiber as well as some manually prepared nanoporous fibers from the samples headspace. To reach the better results, the extraction conditions were carefully optimized for the PDMS fiber. Under the optimized conditions (i.e. sonication time 15 min, extraction time 30 min and extraction temperature 55 ºC, 54 compounds were identified by the UA-HS-SPME-GC/MS method. The essential oil components of Citrus aurantium L. flower samples from two different regions of Iran and new and old samples from the same region were compared to one another. The major components identified for the samples with both the SPME and HD methods were linalool, linalyl acetate, limonene, β-myrcene, geranyl acetate, and neryl acetate, respectively. However, a substantial variation in the percentages of the components was identified for different samples and different extraction methods. The antimicrobial activities of the oil were also examined against six standard bacteria. There was some activity against Enterococcus fecalis, Escherichia coli, and Bacillus cereus, indicating important biological activities of the oil.

  1. Selective molecularly imprinted polymer combined with restricted access material for in-tube SPME/UHPLC-MS/MS of parabens in breast milk samples.

    Science.gov (United States)

    Souza, Israel D; Melo, Lidervan P; Jardim, Isabel C S F; Monteiro, Juliana C S; Nakano, Ana Marcia S; Queiroz, Maria Eugênia C

    2016-08-17

    A new molecularly imprinted polymer modified with restricted access material (a hydrophilic external layer), (MIP-RAM) was synthesized via polymerization in situ in an open fused silica capillary. This stationary phase was used as sorbent for in-tube solid phase microextraction (in-tube SPME) to determine parabens in breast milk samples by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Scanning electron micrographs (SEM) illustrate MIP surface modification after glycerol dimethacrylate (hydrophilic monomer) incorporation. The interaction between parabens and MIP-RAM was investigated by Fourier-transform infrared (FTIR) spectroscopy. The Scatchard plot for MIP-RAM presented two linear parts with different slopes, illustrating binding sites with high- and low-affinity. Endogenous compounds exclusion from the MIP-RAM capillary was demonstrated by in-tube SPME/LC-UV assays carried out with blank milk samples. The in-tube SPME/UHPLC-MS/MS method presented linear range from 10 ng mL(-1) (LLOQ) to 400 ng mL(-1) with coefficients of determination higher than 0.99, inter-assay precision with coefficient of variation (CV) values ranging from 2 to 15%, and inter-assay accuracy with relative standard deviation (RSD) values ranging from -1% to 19%. Analytical validation parameters attested that in-tube SPME/UHPLC-MS/MS is an appropriate method to determine parabens in human milk samples to assess human exposure to these compounds. Analysis of breast milk samples from lactating women demonstrated that the proposed method is effective. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Application of β-cyclodextrin-modified, carbon nanotube-reinforced hollow fiber to solid-phase microextraction of plant hormones.

    Science.gov (United States)

    Song, Xin-Yue; Ha, Wei; Chen, Juan; Shi, Yan-Ping

    2014-12-29

    A new, efficient, and environmental friendly solid-phase microextraction (SPME) medium based on β-cyclodextrin (β-CD)-modified carbon nanotubes (CNTs) and a hollow fiber (HF) was prepared. Functionalized β-CD was covalently linked to the surface of the carboxylic CNTs and then the obtained nanocomposite was immobilized into the wall pores of HFs under ultrasonic-assisted effect. The scanning electron microscope was used to inspect surface characteristics of fibers, demonstrating the presence of nanocomposites in their wall pores. The reinforced HF was employed in SPME, and its extraction performance was evaluated by analyzing 1-naphthaleneacetic acid (NAA) and 2-naphthoxyacetic acid (2-NOA) in vegetables. Without any tedious clean-up procedure, analytes were extracted from the sample to the adsorbent and organic solvent immobilized in HFs and then desorbed in acetonitrile prior to chromatographic analysis. Under the optimized extraction conditions, the method provided 275- and 283-fold enrichment factors of NAA and 2-NOA, low limits of detection and quantification (at an ngg(-1) level), satisfactory spiked recoveries, good inter-fiber repeatability, and batch-to-batch reproducibility. The selectivity of the developed fiber was investigated to three structurally similar compounds and two reference compounds with recognition coefficients up to 3.18. The obtained results indicate that the newly developed fiber is a feasible, selective, green, and cost-effective microextraction medium and could be successfully applied for extraction and determination of naphthalene-derived plant hormones in complex matrices. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Ordered mesoporous carbon film as an effective solid-phase microextraction coating for determination of benzene series from aqueous media.

    Science.gov (United States)

    Jiang, Hui; Li, Jiansheng; Jiang, Mingyue; Lu, Rui; Shen, Jinyou; Sun, Xiuyun; Han, Weiqing; Wang, Lianjun

    2015-08-12

    The present work reports preparation of ordered mesoporous carbon (OMC) film supported on a graphite fiber as a new type of solid-phase microextraction (SPME) fiber for determination of benzene series from aqueous media. The strategy for the supported OMC film preparation was combined dip-coating technology with solvent evaporation-induced self-assembly (EISA) approach. A graphite fiber was immersed in an ethanol solution containing phenolic resin and Pluronic triblock copolymer. Upon solvent evaporation and subsequent pyrolysis under 700 °C, the phenolic resin and the surfactant self-assembled on the surface of the graphite fiber to form smooth OMC film. X-ray diffraction (XRD), transmission electron microscopy (TEM) and nitrogen isothermal adsorption results indicate that the resultant OMC film possesses well-ordered two dimensional hexagonal mesostructure with pore diameters of 4.5 nm and BET surfaces of 630 m(2)/g. Scanning electron microscopy (SEM) studies show the supported OMC film with thickness at 8.5 μm is continuous and defect-free. The SPME efficiency of the OMC fiber was evaluated by analysis of five benzene series (benzene, toluene, ethylbenzene, p-xylene and m-xylene) from water samples by gas chromatography-flame ionization detection (GC-FID). The analysis results indicate that the prepared OMC fiber has wide linear ranges (0.5-500 μg/L), low detection limits (0.01-0.05 μg/L) and good repeatabilities (4.0-5.8% for one fiber, 2.9-8.7% for fiber-to-fiber). Compared with commercial counterparts, the OMC fiber exhibits improved extraction efficiency for benzene series and PAHs. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Determination of N,N-dimethyltryptamine in beverages consumed in religious practices by headspace solid-phase microextraction followed by gas chromatography ion trap mass spectrometry.

    Science.gov (United States)

    Gaujac, Alain; Dempster, Nicola; Navickiene, Sandro; Brandt, Simon D; de Andrade, Jailson Bittencourt

    2013-03-15

    A novel analytical approach combining solid-phase microextraction (SPME)/gas chromatography ion trap mass spectrometry (GC-IT-MS) was developed for the detection and quantification N,N-dimethyltryptamine (DMT), a powerful psychoactive indole alkaloid present in a variety of South American indigenous beverages, such as ayahuasca and vinho da jurema. These particular plant products, often used within a religious context, are increasingly consumed throughout the world following an expansion of religious groups and the availability of plant material over the Internet and high street shops. The method described in the present study included the use of SPME in headspace mode combined GC-IT-MS and included the optimization of the SPME procedure using multivariate techniques. The method was performed with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber in headspace mode (70 min at 60 °C) which resulted in good precision (RSD<8.6%) and accuracy values (71-109%). Detection and quantification limits obtained for DMT were 0.78 and 9.5 mg L(-1), respectively and good linearity (1.56-300 mg L(-1), r(2)=0.9975) was also observed. In addition, the proposed method showed good robustness and allowed for the minimization of sample manipulation. Five jurema beverage samples were prepared in the laboratory in order to study the impact of temperature, pH and ethanol on the ability to extract DMT into solution. The developed method was then applied to the analysis of twelve real ayahuasca and vinho da jurema samples, obtained from Brazilian religious groups, which revealed DMT concentration levels between 0.10 and 1.81 g L(-1). Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Fabrication of a polymeric composite incorporating metal-organic framework nanosheets for solid-phase microextraction of polycyclic aromatic hydrocarbons from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Songbo; Lin, Wei; Xu, Jianqiao [MOE Key Laboratory of Aquatic Product of Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275 (China); Wang, Ying [School of Pharmacy, Guiyang Medical University, Guiyang 550004 (China); Liu, Shuqin; Zhu, Fang [MOE Key Laboratory of Aquatic Product of Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275 (China); Liu, Yuan, E-mail: yliu@shou.edu.cn [College of Food Science & Technology, Shanghai Ocean University, Shanghai 201306 (China); Ouyang, Gangfeng, E-mail: cesoygf@mail.sysu.edu.cn [MOE Key Laboratory of Aquatic Product of Safety/KLGHEI of Environment and Energy Chemistry, School of Chemistry, Sun Yat-sen University, Guangzhou 510275 (China)

    2017-06-08

    In this contribution, it was discovered that even distribution of a metal-organic framework (MOF) [e.g. copper 1,4-benzenedicarboxylate (CBDC)] within polymeric matrixes (e.g. polyimide) resulted in a high-efficient coating material on the surface of a stainless steel wire (SSW). Consequently, a home-made solid phase microextraction (SPME) fiber was fabricated for fast determination of target analytes in real water samples. Scanning electron microscope images indicated that the coating possessed homogenously porous surface. Coupled with gas chromatography-mass spectrometry (GC-MS) and direct immersion SPME (DI-SPME) technique, the fiber was evaluated through the analysis of five polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Under optimized extraction and desorption conditions, the established method based on the home-made fiber exhibited good repeatability (4.2–12.7%, n = 6) and reproducibility (0.9–11.7%, n = 3), low limits of detection (LODs, 0.11–2.10 ng L{sup −1}), low limits of quantification (LOQs, 0.36–6.99 ng L{sup −1}) and wide linear ranges (20–5000 ng L{sup −1}). Eventually, the method was proven applicable in the determination of PAHs in real samples, as the recoveries were in a satisfactory range (81.7–116%). - Highlights: • A homogenously porous CBDC@polyimide-coated fiber was fabricated and characterized. • The fiber exhibited highly desired extraction performance towards PAHs. • The fiber was employed for the determination of PAHs in real aqueous samples.

  6. Preliminary construction of integral analysis for characteristic components in complex matrices by in-house fabricated solid-phase microextraction fibers combined with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tang, Zhentao; Hou, Wenqian; Liu, Xiuming; Wang, Mingfeng; Duan, Yixiang

    2016-08-26

    Integral analysis plays an important role in study and quality control of substances with complex matrices in our daily life. As the preliminary construction of integral analysis of substances with complex matrices, developing a relatively comprehensive and sensitive methodology might offer more informative and reliable characteristic components. Flavoring mixtures belonging to the representatives of substances with complex matrices have now been widely used in various fields. To better study and control the quality of flavoring mixtures as additives in food industry, an in-house fabricated solid-phase microextraction (SPME) fiber was prepared based on sol-gel technology in this work. The active organic component of the fiber coating was multi-walled carbon nanotubes (MWCNTs) functionalized with hydroxyl-terminated polydimethyldiphenylsiloxane, which integrate the non-polar and polar chains of both materials. In this way, more sensitive extraction capability for a wider range of compounds can be obtained in comparison with commercial SPME fibers. Preliminarily integral analysis of three similar types of samples were realized by the optimized SPME-GC-MS method. With the obtained GC-MS data, a valid and well-fit model was established by partial least square discriminant analysis (PLS-DA) for classification of these samples (R2X=0.661, R2Y=0.996, Q2=0.986). The validity of the model (R2=0.266, Q2=-0.465) has also approved the potential to predict the "belongingness" of new samples. With the PLS-DA and SPSS method, further screening out the markers among three similar batches of samples may be helpful for monitoring and controlling the quality of the flavoring mixtures as additives in food industry. Conversely, the reliability and effectiveness of the GC-MS data has verified the comprehensive and efficient extraction performance of the in-house fabricated fiber. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Fabrication of a polymeric composite incorporating metal-organic framework nanosheets for solid-phase microextraction of polycyclic aromatic hydrocarbons from water samples

    International Nuclear Information System (INIS)

    Wei, Songbo; Lin, Wei; Xu, Jianqiao; Wang, Ying; Liu, Shuqin; Zhu, Fang; Liu, Yuan; Ouyang, Gangfeng

    2017-01-01

    In this contribution, it was discovered that even distribution of a metal-organic framework (MOF) [e.g. copper 1,4-benzenedicarboxylate (CBDC)] within polymeric matrixes (e.g. polyimide) resulted in a high-efficient coating material on the surface of a stainless steel wire (SSW). Consequently, a home-made solid phase microextraction (SPME) fiber was fabricated for fast determination of target analytes in real water samples. Scanning electron microscope images indicated that the coating possessed homogenously porous surface. Coupled with gas chromatography-mass spectrometry (GC-MS) and direct immersion SPME (DI-SPME) technique, the fiber was evaluated through the analysis of five polycyclic aromatic hydrocarbons (PAHs) in aqueous samples. Under optimized extraction and desorption conditions, the established method based on the home-made fiber exhibited good repeatability (4.2–12.7%, n = 6) and reproducibility (0.9–11.7%, n = 3), low limits of detection (LODs, 0.11–2.10 ng L −1 ), low limits of quantification (LOQs, 0.36–6.99 ng L −1 ) and wide linear ranges (20–5000 ng L −1 ). Eventually, the method was proven applicable in the determination of PAHs in real samples, as the recoveries were in a satisfactory range (81.7–116%). - Highlights: • A homogenously porous CBDC@polyimide-coated fiber was fabricated and characterized. • The fiber exhibited highly desired extraction performance towards PAHs. • The fiber was employed for the determination of PAHs in real aqueous samples.

  8. Graphitic carbon nitrides modified hollow fiber solid phase microextraction for extraction and determination of uric acid in urine and serum coupled with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Sun, Ying-pei; Chen, Juan; Qi, Huan-yang; Shi, Yan-ping

    2015-11-01

    An elevated uric acid (UA) in urine or serum can affect renal function and blood pressure, which is an indicator of gout, cardiovascular and renal diseases, hypertension, etc. In this work, a new type of mixed matrix membrane (MMM), based on graphitic carbon nitrides (g-CNs) and hollow fiber (HF), was prepared and combined with solid phase microextraction (SPME) mode to determine UA in urine and serum followed by gas chromatography-mass spectrometry (GC/MS). The porous g-CNs were dispersed in ammonia, and then the exfoliated g-CNs nanosheets were held in the pores of HF by capillary forces and sonification. The prepared g-CNs modified HF (g-CNs-HF) was immersed in biofluid directly to extract UA with SPME mode and the solvent-free mode is convenient for further derivatization and analysis. To achieve the highest extraction efficiency (EF), main extraction and derivatization parameters, such as g-CNs-HF immobilizing time, sonification power and time of extraction, derivatization and desorption time, were optimized. Under the optimum extraction conditions, a favorable linearity of UA was obtained in the range 0.1-200μgmL(-1) with correlation coefficients higher than 0.9990, and the average recoveries at three spiked levels of UA in urine and serum ranged from 80.7% to 121.6%, from 84.7% to 101.1%, respectively. The obtained results demonstrated the developed g-CNs-HF-SPME is a simple, rapid, cost-effective, solvent-free method for the analysis of UA in biofluid. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Automated determination of aliphatic primary amines in wastewater by simultaneous derivatization and headspace solid-phase microextraction followed by gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Llop, Anna; Pocurull, Eva; Borrull, Francesc

    2010-01-22

    This paper presents a fully automated method for determining ten primary amines in wastewater at ng/L levels. The method is based on simultaneous derivatization with pentafluorobenzaldehyde (PFBAY) and headspace solid-phase microextraction (HS-SPME) followed by gas chromatography coupled to ion trap tandem mass spectrometry (GC-IT-MS-MS). The influence of main factors on the efficiency of derivatization and of HS-SPME is described in detail and optimized by a central composite design. For all species, the highest enrichment factors were achieved using a 85 microm polyacrylate (PA) fiber exposed in the headspace of stirred water samples (750 rpm) at pH 12, containing 360 g/L of NaCl, at 40 degrees C for 15 min. Under optimized conditions, the proposed method achieved detection limits ranging from 10 to 100 ng/L (except for cyclohexylamine). The optimized method was then used to determine the presence of primary amines in various types of wastewater samples, such as influent and effluent wastewater from municipal and industrial wastewater treatment plants (WWTPs) and a potable water treatment plant. Although the analysis of these samples revealed the presence of up to 1500 microg/L of certain primary amines in influent industrial wastewater, the concentration of these compounds in the effluent and in municipal and potable water was substantially lower, at low microg/L levels. The new derivatization-HS-SPME-GC-IT-MS-MS method is suitable for the fast, reliable and inexpensive determination of primary amines in wastewater in an automated procedure. Copyright 2009 Elsevier B.V. All rights reserved.

  10. Molecularly imprinted sol-gel nanofibers based solid phase microextraction coupled on-line with high performance liquid chromatography for selective determination of acesulfame.

    Science.gov (United States)

    Moein, Mohammad Mahdi; Javanbakht, Mehran; Karimi, Mohammad; Akbari-Adergani, Behrouz

    2015-03-01

    Sol-gel based molecularly imprinted polymer (MIP) nanofiber was successfully fabricated by electrospinning technique on the surface of a stainless steel bar. The manufactured tool was applied for on-line selective solid phase microextraction (SPME) and determination of acesulfame (ACF) as an artificial sweetener with high performance liquid chromatography (HPLC). The selective ability of method for the extraction of ACF was investigated in the presence of some selected sweeteners such as saccharine (SCH), aspartame (ASP) and caffeine (CAF). Electrospinning of MIP sol-gel solution on the stainless steel bar provided an unbreakable sorbent with high thermal, mechanical, and chemical stability. Moreover, application of the MIP-SPME tool revealed a unique approach for the selective microextraction of the analyte in beverage samples. In this work, 3-(triethoxysilyl)-propylamine (TMSPA) was chosen as a precursor due to its ability to imprint the analyte by hydrogen bonding, Van der Walls, and dipole-dipole interactions. Nylon 6 was also added as a backbone and support for the precursor in which sol could greatly growth during the sol-gel process and makes the solution electrospinable. Various effective parameters in the extraction efficiency of the MIP-SPME tool such as loading time, flow rate, desorption time, selectivity, and the sample volume were evaluated. The linearity for the ACF in beverage sample was in the range of 0.78-100.5 ng mL(-1). Limit of detection (LOD) and quantification (LOQ) were 0.23 and 0.78 ng mL(-1) respectively. The RSD values (n=5) were all below 3.5%at the 20 ng mL(-1) level. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Direct quantitation of volatile organic compounds in packaging materials by headspace solid-phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Ezquerro, Scar; Pons, Begoña; Tena, María Teresa

    2003-01-24

    The quantification of volatile organic compounds (VOCs) in flexible multilayer packaging materials using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) was studied. The analytes imclude 22 compounds such as aldehydes. ketones, carboxylic acids and hydrocarbons formed by thermooxidative degradation of polyethylene during the extrusion coating process in the manufacture of the packaging, and many of them are involved in the unpleasant and undesirable odour of these materials. External standard calibration using a solution of the analytes in an appropriate solvent was the first approach studied. Aqueous solutions of the analytes provided low reproducibility and the reduction of aldehydes to alcohols under the HS-SPME conditions. Hexadecane was chosen as the solvent since its polarity is similar to that of polyethylene and its volatility is lower than that of the analytes. However, hexadecane should be added to the sample before the analysis as it modifies the absorption capacity of the fibre. A 75-microm Carboxen-poly(dimethylsiloxane) fibre was used to extract the VOCs from the headspace above the packaging in a 15-ml sealed vial at 100 degrees C after 5 min of preincubation. The influence of the extraction time on the amount extracted was studied for a standard solution of the analytes in hexadecane, together with the influence of the volume of the standard solution and the amount of the sample placed in the vial. Standard addition and multiple HS-SPME were also studied as calibration methods and the results obtained in the quantitative analysis of a packaging material were compared.

  12. A simple and automated method to determine macrocyclic musk fragrances in sewage sludge samples by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Vallecillos, Laura; Pocurull, Eva; Borrull, Francesc

    2013-11-01

    For the first time, headspace solid-phase microextraction (HS-SPME) has shown to be a powerful technique to extract macrocyclic musk fragrances directly from sewage sludge. It avoids the need to use additional extraction/preconcentration techniques or clean-up procedure and facilitates the automation of the method. Thus, a simple and fully automated method based on HS-SPME and GC-MS has been developed which allows the determination of eight macrocyclic musk fragrances at ngg(-1) (d.w.) levels. The optimal HS-SPME conditions were achieved when a PDMS/DVB 65μm fibre was exposed for 45min in the headspace of 0.25g sewage sludge samples mixed with 0.5mL of water stirred at 750rpm at 80°C. Optimal desorption conditions were found to be 250°C for 3min. Method detection limits were found in the low pgg(-1) range between 10pgg(-1) (d.w.) and 25pgg(-1) (d.w.) depending on the target analytes. In addition, under optimized conditions, the method gave good levels of intra-day and inter-day repeatabilities in sewage sludge with relative standard deviations varying between 1% to 9% and 6% to 15% respectively (n=5, 1000pgg(-1) d.w.). The applicability of the method was tested with sewage sludge from three urban sewage treatment plants (STPs). The analysis revealed the presence of the macrocyclic musks studied in several samples, with concentrations ranging between below MQL (method quantification limit) and 0.89ngg(-1) (d.w.). Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Solid lubrication design methodology, phase 2

    Science.gov (United States)

    Pallini, R. A.; Wedeven, L. D.; Ragen, M. A.; Aggarwal, B. B.

    1986-01-01

    The high temperature performance of solid lubricated rolling elements was conducted with a specially designed traction (friction) test apparatus. Graphite lubricants containing three additives (silver, phosphate glass, and zinc orthophosphate) were evaluated from room temperature to 540 C. Two hard coats were also evaluated. The evaluation of these lubricants, using a burnishing method of application, shows a reasonable transfer of lubricant and wear protection for short duration testing except in the 200 C temperature range. The graphite lubricants containing silver and zinc orthophosphate additives were more effective than the phosphate glass material over the test conditions examined. Traction coefficients ranged from a low of 0.07 to a high of 0.6. By curve fitting the traction data, empirical equations for slope and maximum traction coefficient as a function of contact pressure (P), rolling speed (U), and temperature (T) can be developed for each lubricant. A solid lubricant traction model was incorporated into an advanced bearing analysis code (SHABERTH). For comparison purposes, preliminary heat generation calculations were made for both oil and solid lubricated bearing operation. A preliminary analysis indicated a significantly higher heat generation for a solid lubricated ball bearing in a deep groove configuration. An analysis of a cylindrical roller bearing configuration showed a potential for a low friction solid lubricated bearing.

  14. Nanorod Array Solid State Neutron Detectors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase I SBIR project, Synkera proposes to develop and commercialize solid-state neutron detectors of a unique architecture that will enable sensor modules...

  15. Insight into solid-liquid phase transfer catalyzed synthesis of ...

    Indian Academy of Sciences (India)

    Insight into solid-liquid phase transfer catalyzed synthesis of Mecoprop ester using K₂CO₃ as base and development of new kinetic model involving liquid product and two solid co-products. GANAPATI D YADAV GUNJAN P DESHMUKH. REGULAR ARTICLE Volume 129 Issue 11 November 2017 pp 1677-1685 ...

  16. Solid phase microextraction-high performance liquid chromatographic determination of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in the presence of sodium dodecyl sulfate surfactant.

    Science.gov (United States)

    Malik, Ashok Kumar; Rai, Parmod Kumar

    2008-07-01

    A simple and sensitive method has been developed using preconcentration technique solid phase microextraction (SPME) and analytical technique HPLC-UV for the determination of octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) from the environmental samples. Aqueous solution of anionic surfactant SDS was used for the extraction of both nitramine high explosives, viz., HMX and RDX from soil samples which were subsequently sorbed on SPME fiber. The static desorption was carried out in the desorption chamber of the SPME-HPLC interface in the presence of mobile phase ACN/methanol/water (30:35:35) and the subsequent chromatographic analysis at a flow rate of 0.5 mL/min and detection at 230 nm. For this purpose, a C(18), 5 microm RP analytical column was used as a separation medium in this method. Several parameters relating to SPME, e.g., adsorption/desorption time, concentration of salt, stirring rate, etc., were optimized. The method was linear over the range of 20-400 ng/mL for HMX and RDX standards in the presence of surfactant in aqueous phase, respectively. The correlation coefficient (R(2)) for HMX and RDX are 0.9998 and 0.9982, respectively. With SPME, the detection limits (S/N = 3) in ng/mL are 0.05 and 0.1 for HMX and RDX, respectively in the presence of the SDS surfactant. The developed method has been applied successfully to the analysis of real environmental samples like bore well water, river water, and ground alluvial soil.

  17. Method for sampling and analysis of volatile biomarkers in process gas from aerobic digestion of poultry carcasses using time-weighted average SPME and GC-MS.

    Science.gov (United States)

    Koziel, Jacek A; Nguyen, Lam T; Glanville, Thomas D; Ahn, Heekwon; Frana, Timothy S; Hans van Leeuwen, J

    2017-10-01

    A passive sampling method, using retracted solid-phase microextraction (SPME) - gas chromatography-mass spectrometry and time-weighted averaging, was developed and validated for tracking marker volatile organic compounds (VOCs) emitted during aerobic digestion of biohazardous animal tissue. The retracted SPME configuration protects the fragile fiber from buffeting by the process gas stream, and it requires less equipment and is potentially more biosecure than conventional active sampling methods. VOC concentrations predicted via a model based on Fick's first law of diffusion were within 6.6-12.3% of experimentally controlled values after accounting for VOC adsorption to the SPME fiber housing. Method detection limits for five marker VOCs ranged from 0.70 to 8.44ppbv and were statistically equivalent (p>0.05) to those for active sorbent-tube-based sampling. The sampling time of 30min and fiber retraction of 5mm were found to be optimal for the tissue digestion process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Investigation of binary solid phases by calorimetry and kinetic modelling

    OpenAIRE

    Matovic, M.

    2007-01-01

    The traditional methods for the determination of liquid-solid phase diagrams are based on the assumption that the overall equilibrium is established between the phases. However, the result of the crystallization of a liquid mixture will typically be a non-equilibrium or metastable state of the solid. For a proper description of the crystallization process the equilibrium approach is insufficient and a kinetic approach is actually required. In this work, we show that during slow crystallizatio...

  19. Combinatorial Solid-Phase Synthesis of Balanol Analogues

    DEFF Research Database (Denmark)

    Nielsen, John; Lyngsø, Lars Ole

    1996-01-01

    The natural product balanol has served as a template for the design and synthesis of a combinatorial library using solid-phase chemistry. Using a retrosynthetic analysis, the structural analogues have been assembled from three relatively accessible building blocks. The solid-phase chemistry...... including MSNT-mediated esterification of both support-bound alcohols and carboxylic acids has been implemented successfully. Copyright (C) 1996 Elsevier Science Ltd....

  20. Determination of Methyl tert-Butyl Ether and tert-Butyl Alcohol in Water by Solid-Phase Microextraction/Head Space Analysis in Comparison to EPA Method 5030/8260B

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Keun-Chan; Stringfellow, William T.

    2003-10-02

    Methyl tert-butyl ether (MTBE) is now one of the most common groundwater contaminants in the United States. Groundwater contaminated with MTBE is also likely to be contaminated with tert-butyl alcohol (TBA), because TBA is a component of commercial grade MTBE, TBA can also be used as a fuel oxygenate, and TBA is a biodegradation product of MTBE. In California, MTBE is subject to reporting at concentrations greater than 3 {micro}g/L. TBA is classified as a ''contaminant of current interest'' and has a drinking water action level of 12 {micro}g/L. In this paper, we describe the development and optimization of a simple, automated solid phase microextraction (SPME) method for the analysis of MTBE and TBA in water and demonstrate the applicability of this method for monitoring MTBE and TBA contamination in groundwater, drinking water, and surface water. In this method, the headspace (HS) of a water sample is extracted with a carboxen/polydimethylsiloxane SPME fiber, the MTBE and TBA are desorbed into a gas chromatograph (GC), and detected using mass spectrometry (MS). The method is optimized for the routine analysis of MTBE and TBA with a level of quantitation of 0.3 {micro}g/L and 4 {micro}g/L, respectively, in water. MTBE quantitation was linear for over two orders of concentration (0.3 {micro}g/L -80 {micro}g/L). TBA was found to be linear within the range of 4 {micro}g/L-7,900 {micro}g/L. The lower level of detection for MTBE is 0.03 {micro}g/L using this method. This SPME method using headspace extraction was found to be advantageous over SPME methods requiring immersion of the fiber into the water samples, because it prolonged the life of the fiber by up to 400 sample analyses. This is the first time headspace extraction SPME has been shown to be applicable to the measurement of both MTBE and TBA at concentrations below regulatory action levels. This method was compared with the certified EPA Method 5030/8260B (purge-and-trap/GC/MS) using split

  1. The Structural Phase Transition in Solid DCN

    DEFF Research Database (Denmark)

    Dietrich, O. W.; Mackenzie, Gordon A.; Pawley, G. S.

    1975-01-01

    Neutron scattering measurements on deuterated hydrogen cyanide have shown that the structural phase change from a tetragonal to an orthorhombic form at 160K is a first-order transition. A transverse acoustic phonon mode, which has the symmetry of the phase change, was observed at very low energies...

  2. Magnetic Solid Phase Extraction Applied to Food Analysis

    Directory of Open Access Journals (Sweden)

    Israel S. Ibarra

    2015-01-01

    Full Text Available Magnetic solid phase extraction has been used as pretreatment technique for the analysis of several compounds because of its advantages when it is compared with classic methods. This methodology is based on the use of magnetic solids as adsorbents for preconcentration of different analytes from complex matrices. Magnetic solid phase extraction minimizes the use of additional steps such as precipitation, centrifugation, and filtration which decreases the manipulation of the sample. In this review, we describe the main procedures used for synthesis, characterization, and application of this pretreatment technique which were applied in food analysis.

  3. Solid-Phase S-Alkylation Promoted by Molecular Sieves.

    Science.gov (United States)

    Calce, Enrica; Leone, Marilisa; Mercurio, Flavia Anna; Monfregola, Luca; De Luca, Stefania

    2015-11-20

    A solid-phase S-alkylation procedure to introduce chemical modification on the cysteine sulfhydryl group of a peptidyl resin is reported. The reaction is promoted by activated molecular sieves and consists of a solid-solid process, since both the catalyst and the substrate are in a solid state. The procedure was revealed to be efficient and versatile, particularly when used in combination with the solution S-alkylation approach, allowing for the introduction of different molecular diversities on the same peptide molecule.

  4. Headspace solid-phase microextraction gas chromatography-mass spectrometry analysis of volatiles in orujo spirits from a defined geographical origin.

    Science.gov (United States)

    Peña, Rosa M; Barciela, Julia; Herrero, Carlos; García-Martín, Sagrario

    2008-04-23

    A headspace solid-phase microextraction (HS-SPME) and gas chromatography-selective ion monitoring/mass spectrometry (GC-SIM/MS) method was optimized for analysis of 22 volatile compounds in orujo spirit samples from the Geographic Denomination "Orujo de Galicia/Augardente de Galicia". HS-SPME experimental conditions, such as fiber coating, extraction temperature, extraction and pre-equilibrium time, sample volume, and the presence of salt, were studied to improve the extraction process. The best results were obtained using a 65 microm Carbowax-divinylbenzene fiber during a headspace extraction at 40 degrees C with constant magnetic stirring for 15 min and after a 5 min period of pre-equilibrium time. The sample volume was 6 mL of orujo containing 25% of NaCl, placed in 12 mL glass vials equipped with a screw cap and PTFE/silicone septum. Desorption was performed directly in the gas chromatograph injector port for 5 min at 250 degrees C using the splitless mode. The proposed method is sensible (with detection limits between 0.0045 and 0.2399 mg/L), precise (with coefficients of variation in the range 0.99-8.18%), and linear over more than 1 order of magnitude. The developed method presented recoveries comprised between 76.0 and 112.4%. The applicability of the new method was demonstrated by determining the considered 22 volatile compounds in nine orujo commercial samples with quality and origin brands.

  5. Polypyrrole nanowire as an excellent solid phase microextraction fiber for bisphenol A analysis in food samples followed by ion mobility spectrometry.

    Science.gov (United States)

    Kamalabadi, Mahdie; Mohammadi, Abdorreza; Alizadeh, Naader

    2016-08-15

    A polypyrrole nanowire coated fiber was prepared and used in head-space solid phase microextraction coupled with ion mobility spectrometry (HS-SPME-IMS) to the analysis of bisphenol A (BPA) in canned food samples, for the first time. This fiber was synthesized by electrochemical oxidation of the monomer in aqueous solution. The fiber characterization by scanning electron microscopy (SEM) revealed that the new fiber exhibited two-dimensional structures with a nanowire morphology. The effects of important extraction parameters on the efficiency of HS-SPME were investigated and optimized. Under the optimum conditions, the linearity of 10-150ngg(-1) and limit of detection (based on S/N=3) of 1ngg(-1) were obtained in BPA analysis. The repeatability (n=5) expressed as the relative standard deviation (RSD%) was 5.8%. At the end, the proposed method was successfully applied to determine BPA in various canned food samples (peas, corns, beans). Relative recoveries were obtained 93-96%. Method validation was conducted by comparing our results with those obtained through HPLC with fluorescence detection (FLD). Compatible results indicate that the proposed method can be successfully used in BPA analysis. This method is simple and cheaper than chromatographic methods, with no need of extra organic solvent consumption and derivatization prior to sample introduction. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Combined solid-phase microextraction and high-performance liquid chromatography with ultroviolet detection for simultaneous analysis of clenbuterol, salbutamol and ractopamine in pig samples.

    Science.gov (United States)

    Du, Wei; Zhang, Siruo; Fu, Qiang; Zhao, Gang; Chang, Chun

    2013-12-01

    A simple and sensitive method based on the combination of solid-phase microextraction (SPME) and high-performance liquid chromatography with ultroviolet detection was developed for the simultaneous determination of clenbuterol, salbutamol and ractopamine in pig samples. Parameters of the SPME procedure affecting extraction efficiency, such as the type of fiber, extraction time, extraction temperature, ion strength, pH of sample and stirring rate, were optimized. The developed method was validated according to the International Conference on Harmonization guidelines. The calibration curves were linear over a range of 0.5-50 µg/L for clenbuterol and ractopamine, and 0.2-20 µg/L for salbutamol. The limits of detection were 0.1 µg/L for clenbuterol, 0.05 µg/L for salbutamol and 0.1 μg/L for ractopamine, respectively. The averages of intra- and inter-day accuracy ranged from 79.8 to 92.4%. The intra-day and inter-day precision were below 9.6% for the three analytes. This method exhibited the advantages of simplicity, rapidity and low solvent consumption, and was suitable for the monitoring of β2 -agonists residue in pig samples. Copyright © 2013 John Wiley & Sons, Ltd.

  7. Monitoring of gamma radiolytic degradation products of methoxychlor pesticide in water by solid phase micro-extraction using hplc and GC-MS (abstract)

    International Nuclear Information System (INIS)

    Butt, S.B.; Zafar, A.

    2011-01-01

    Monitoring, removal and management of toxic chemicals is an essential area of study regarding sustainable progress. Different approaches are adopted to eliminate these water born toxics from water and waste water. Among these gamma radiolytic is an emerging option. This ionization radiation generates highly reactive radicals that reacts with pollutants and hence eliminates these. A solid-phase micro-extraction (SPME) procedure has been developed for the successful preconcentration of organic pollutant irradiated water. A SPME fused-silica fiber coated with Polyacrylate was used as a probe to extract the organic pollutant after irradiation. In this reference, degradation of priority organic pollutant methoxychlor (1, 1, 1-Trichloro 2, 2-bis (p-methoxyphenyl) ethane, in water by gamma irradiation under varied experimental conditions has been investigated. The degree of gamma radiolytic degradation was monitored by HPLC-UV and GC-MS. For 4 kGy and 5 kGy gamma radiation dose at a rate of 200 kGyh/sup -1/ greater or equal to 95 % and 98 % MXC was degraded respectively. The degradation products were identified by Mass Spectrometry after comparing their MS spectras with the NIST 98 library. The major degradation occurs via dechlorination, dehydro chlorination, by the detachment of methoxyphenyl from MXC and by interaction of other radicals generated by the water radiolysis. (author)

  8. Identification of halogenated photoproducts generated after ultraviolet-irradiation of parabens and benzoates in water containing chlorine by solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Alvarez-Rivera, Gerardo; Llompart, Maria; Garcia-Jares, Carmen; Lores, Marta

    2014-07-04

    This work presents a new solid-phase microextraction (SPME)-based approach to investigate the formation of halogenated by-products generated by the UV-induced photodegradation of parabens and their congener benzoates in water containing chlorine. Degradation of parent species, and further identification of their transformation by-products were monitored by gas chromatography coupled to mass spectrometry (GC/MS). In order to improve detectability, SPME was applied as a preconcentration step after UV-irradiation of target preservatives. Experiments performed with dechlorinated water, ultrapure water, and tap water showed that under UV-light, the presence of even low levels of free chlorine, increases the photodegradation rate of target preservatives, enhancing the formation of halogenated photoproducts. Monobrominated, dibrominated and bromochlorinated hydroxybenzoates were identified, and the transformation of benzoates into halogenated parabens was also confirmed. Bromination is expected to occur when free chlorine is present, due to the presence of traces of bromide in water samples. Five halogenated phenols (mainly brominated) were detected as breakdown photoproducts from both families of target preservatives. On the basis of the appearance of the aforementioned by-products, a tentative transformation pathway, consistent with the photoformation-photodecay kinetics of the by-products, is proposed herein for the first time. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Carbon nanotubes@silicon dioxide nanohybrids coating for solid-phase microextraction of organophosphorus pesticides followed by gas chromatography-corona discharge ion mobility spectrometric detection.

    Science.gov (United States)

    Saraji, Mohammad; Jafari, Mohammad Taghi; Mossaddegh, Mehdi

    2016-01-15

    A high efficiency solid-phase microextraction (SPME) fiber coated with porous carbon nanotubes-silicon dioxide (CNTs-SiO2) nanohybrids was synthesized and applied for the determination of some organophosphorus pesticides (OPPs) in vegetables, fruits and water samples. Gas chromatography-corona discharge ion mobility spectrometry was used as the detection system. Glucose, as a biocompatible compound, was used for connecting CNT and SiO2 during a hydrothermal process. The electrospinning technique was also applied for the fiber preparation. The parameters affecting the efficiency of extraction, including stirring rate, salt effect, extraction temperature, extraction time, desorption temperature and desorption time, were investigated and optimized. The developed CNTs@SiO2 fiber presented better extraction efficiency than the commercial SPME fibers (PA, PDMS, and PDMS-DVB). The intra- and inter-day relative standard deviations were found to be lower than 6.2 and 9.0%, respectively. For water samples, the limits of detection were in the range of 0.005-0.020 μg L(-1) and the limits of quantification were between 0.010 and 0.050 μg L(-1). The results showed a good linearity in the range of 0.01-3.0 μg L(-1) for the analytes. The spiking recoveries ranged from 79 (± 9) to 99 (± 8). The method was successfully applied for the determination of OPPs in real samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Simultaneous in-vial acetylation solid-phase microextraction followed by gas chromatography tandem mass spectrometry for the analysis of multiclass organic UV filters in water.

    Science.gov (United States)

    Vila, Marlene; Celeiro, Maria; Lamas, J Pablo; Garcia-Jares, Carmen; Dagnac, Thierry; Llompart, Maria

    2017-02-05

    UV filters are a class of emerging contaminants that are widely used in personal care products (PCPs) and that can be detected at low concentrations in the aquatic environment (ngL -1 ). Sensitive modern analytical methods are then mandatory to accurately analyze them. A methodology based on solid-phase-microextraction (SPME), considered as a 'Green Chemistry' technique, followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for the simultaneous analysis of 14 UV filters of different chemical nature in environmental and recreational waters. In-vial low-cost derivatization was carried out to improve chromatographic performance of phenolic compounds. The extraction parameters (fiber coating, extraction mode, and salt addition) were optimized by means of experimental designs in order to achieve reliable conditions. Finally, the SPME-GC-MS/MS method was validated in terms of linearity, accuracy and precision with LODs in the low ngL -1 level. Its application to the analysis of 28 different samples including sea, river, spa, swimming pool, and aquapark waters, enabled the detection of 11 target UV filters at concentration levels up to 540μgL -1 , highlighting the presence of OCR in all analyzed samples and of 2EHMC (proposed to be considered as priority pollutant) in 79% of them. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Dye-doped nanostructure polypyrrole film for electrochemically switching solid-phase microextraction of Ni(II) and ICP-OES analysis of waste water.

    Science.gov (United States)

    Shamaeli, Ehsan; Alizadeh, Naader

    2012-01-01

    A nanostructure fiber based on conducting polypyrrole synthesized by an electrochemical method has been developed, and used for electrochemically switching solid-phase microextraction (ES-SPME). The ES-SPME was prepared by the doping of eriochrome blue in polypyrrole (PPy-ECB) and used for selectively extracting the Ni(II) cation in the presence of some transition and heavy metal ions. The cation-exchange behavior of electrochemically prepared polypyrrole on stainless-steel with and without eriochrome blue (ECB) dye was characterized using ICP-OES analysis. The effects of the scan rate for electrochemical synthesis, uptake and the release potential on the extraction behavior of the PPy-ECB conductive fiber were studied. Uptake and release time profiles show that the process of electrically switched cation exchange could be completed within 250 s. The results of the present study point concerning the possibility of developing a selective extraction process for Ni(II) from waste water was explored using such a nanostructured PPy-ECB film through an electrically switched cation exchange. 2012 © The Japan Society for Analytical Chemistry

  12. In situ hydrothermal growth of polyaniline coating for in-tube solid-phase microextraction towards ultraviolet filters in environmental water samples.

    Science.gov (United States)

    Bu, Yanan; Feng, Juanjuan; Wang, Xiuqin; Tian, Yu; Sun, Min; Luo, Chuannan

    2017-02-03

    A facile, low cost, sensitive and environmentally friendly polyaniline (PANI) coating was prepared onto the basalt fibers (BFs) by in situ hydrothermal growth method. PANI functionalized BFs were placed into a poly(ether ether ketone) (PEEK) tube as a fibers-in-tube solid-phase microextraction (SPME) device. The extraction and analysis processes were carried out by connecting it to high performance liquid chromatography (HPLC). Three ultraviolet filters including 2-hydroxy-4-methoxybenzophenone, phenyl salicylate and 2,4-dihydroxybenzophenone were employed as model analytes. Under the optimal extraction and desorption conditions, online in-tube SPME-HPLC analysis method was established and afforded satisfactory enrichment factors (1323-1555), wide linear ranges (0.06-100μgL -1 ) with correlation coefficients ranging from 0.9995 to 0.9999, low limits of detection (0.02-0.05μgL -1 ) and acceptable extraction repeatability (RSD<7.8%, n=6) and preparation repeatability (RSD<9.7%, n=3). The proposed method was successfully applied to the determination of the three ultraviolet filters in two environmental water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Simple and sensitive analysis of nereistoxin and its metabolites in human serum using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Namera, A; Watanabe, T; Yashiki, M; Kojima, T; Urabe, T

    1999-03-01

    A simple method for the analysis of nereistoxin and its metabolites in human serum using headspace solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) is developed. A vial containing a serum sample, 5M sodium hydroxide, and benzylacetone (internal standard) is heated to 70 degrees C, and an SPME fiber is exposed for 30 min in the headspace of the vial. The compounds extracted by the fiber are desorbed by exposing the fiber in the injection port of the GC-MS. The calibration curves show linearity in the range of 0.05-5.0 micrograms/mL for nereistoxin and N-methyl-N-(2-methylthio-1-methylthiomethyl)ethylamine, 0.01-5.0 micrograms/mL for S,S'-dimethyl dihydronereistoxin, and 0.5-10 micrograms/mL for 2-methylthio-1-methylthiomethylethylamine in serum. No interferences are found, and the analysis time is 50 min for one sample. In addition, this proposed method is applied to a patient who attempted suicide by ingesting Padan 4R, a herbicide. Padan 4R contains 4% cartap hydrochloride, which is an analogue of nereistoxin. Nereistoxin and its metabolites are detected in the serum samples collected from the patient during hospitalization. The concentration ranges of nereistoxin in the serum are 0.09-2.69 micrograms/mL.

  14. The investigation of exposure to benzene, toluene, ethylbenzene and xylene (BTEX with Solid Phase Microextr action Method in gas station in Yazd province

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Mosaddegh Mehrjerdi

    2014-01-01

    Full Text Available Abstract Background: Benzene, toluene, ethylbenzene and xylene (BTEX are volatile organic compounds which their physical and chemical characteristics are similar. Evaporation of BTEX from gasoline in petrol station into the air causes gasoline station attendants expose to them. A new extraction method of volatile organic compounds is solid phase microextraction (SPME. The aim of this study is to optimize extraction conditions of BTEX from air samples and then determination of gasoline station air contamination with BTEX in Yazd. Material and Methods: In this study air samples were collected using Tedlar bags and then extracted and analyzed with SPME fiber and gas chromatography equipped with a flame ionization detector. Results: Our results indicate that PDMS/CAR has the best peak area in comparison with two other fibers The Optimized extraction and desorption times are estimated 3 and 1 minutes, respectively Mean concentration of benzene, toluene, ethyl benzene and xylene in gas station’s air were 1932±807, 667±405, 148±89, 340±216 µg/m3 respectively. Conclusion: Benzene mean concentration is above threshold limit value (0.5PPM. Whereas, toluene, ethylbenzene and xylene mean concentration are lower than threshold limit values.

  15. Comparison of Spot and Time Weighted Averaging (TWA Sampling with SPME-GC/MS Methods for Trihalomethane (THM Analysis

    Directory of Open Access Journals (Sweden)

    Don-Roger Parkinson

    2016-02-01

    Full Text Available Water samples were collected and analyzed for conductivity, pH, temperature and trihalomethanes (THMs during the fall of 2014 at two monitored municipal drinking water source ponds. Both spot (or grab and time weighted average (TWA sampling methods were assessed over the same two day sampling time period. For spot sampling, replicate samples were taken at each site and analyzed within 12 h of sampling by both Headspace (HS- and direct (DI- solid phase microextraction (SPME sampling/extraction methods followed by Gas Chromatography/Mass Spectrometry (GC/MS. For TWA, a two day passive on-site TWA sampling was carried out at the same sampling points in the ponds. All SPME sampling methods undertaken used a 65-µm PDMS/DVB SPME fiber, which was found optimal for THM sampling. Sampling conditions were optimized in the laboratory using calibration standards of chloroform, bromoform, bromodichloromethane, dibromochloromethane, 1,2-dibromoethane and 1,2-dichloroethane, prepared in aqueous solutions from analytical grade samples. Calibration curves for all methods with R2 values ranging from 0.985–0.998 (N = 5 over the quantitation linear range of 3–800 ppb were achieved. The different sampling methods were compared for quantification of the water samples, and results showed that DI- and TWA- sampling methods gave better data and analytical metrics. Addition of 10% wt./vol. of (NH42SO4 salt to the sampling vial was found to aid extraction of THMs by increasing GC peaks areas by about 10%, which resulted in lower detection limits for all techniques studied. However, for on-site TWA analysis of THMs in natural waters, the calibration standard(s ionic strength conditions, must be carefully matched to natural water conditions to properly quantitate THM concentrations. The data obtained from the TWA method may better reflect actual natural water conditions.

  16. A preconcentrator chip employing μ-SPME array coated with in-situ-synthesized carbon adsorbent film for VOCs analysis.

    Science.gov (United States)

    Wong, Ming-Yee; Cheng, Wei-Rui; Liu, Mao-Huang; Tian, Wei-Cheng; Lu, Chia-Jung

    2012-11-15

    We report the design, fabrication, and evaluation of a μ-preconcentrator chip that utilizes an array of solid-phase microextraction (SPME) needles coated with in-situ-grown carbon adsorbent film. The structure of the SPME needle (diameter=100 μm, height=250 μm) array inside the sampling chamber was fabricated using a deep reactive-ion etching (DRIE) process to enhance the attachable surface area for adsorbent film. Heaters and temperature sensors were fabricated onto the back of a μ-preconcentrator chip using lithography patterning and a metal lift-off process. The devices were sealed by anodic bonding and diced prior to the application of the adsorbent film. An adsorbent precursor, cellulose was dissolved in water and dynamically coated onto the SPME needle array. The coated cellulose film was converted into a porous carbon film via pyrolysis at 600 °C in a N(2) atmosphere. The surface area of the carbon adsorbent film was 308 m(2)/g, which is higher than that of a commercial adsorbent Carbopack X. A preconcentration factor as high as 13,637-fold was demonstrated using toluene. Eleven volatile organic compounds (VOCs) of different volatilities and functional groups were sampled and analyzed by GC-FID, and the desorption peak widths at half height were all less than 2.6 s after elution from a 15m capillary GC column. There was no sign of performance degradation after continuous operation for 50 cycles in air. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. HS-SPME-GC×GC-qMS volatile metabolite profiling of Chrysolina herbacea frass and Mentha spp. leaves.

    Science.gov (United States)

    Cordero, Chiara; Zebelo, Simon Atsbaha; Gnavi, Giorgio; Griglione, Alessandra; Bicchi, Carlo; Maffei, Massimo E; Rubiolo, Patrizia

    2012-02-01

    Headspace solid-phase microextraction (HS-SPME) comprehensive two-dimensional (2D) gas chromatography combined with quadrupole-mass spectrometry (GC×GC-qMS) with dedicated comparative data elaboration was applied to separate chemical patterns arising from the interaction between some Mentha species and the herbivore Chrysolina herbacea, also known as the mint bug. Upon feeding on different Mentha species (Mentha spicata L., Mentha × piperita L. and Mentha longifolia L.), C. herbacea produced frass (faeces) which were characterized by a typical volatile fraction. HS-SPME GC×GC-qMS analysis of the complex volatile fraction of both mint leaf and C. herbacea frass was submitted to advanced fingerprinting analysis of 2D chromatographic data. 1,8-Cineole, found in the leaves of all the Mentha species examined, was oxidized, and C. herbacea frass yielded high rates of several hydroxy-1,8-cineoles, including 2α-hydroxy-, 3α-hydroxy-, 3β-hydroxy- and 9-hydroxy-1,8-cineole. Upon insect feeding, several unknown oxidized monoterpenes, a p-menthane diol and three unknown phenylpropanoids were also detected in the frass volatiles. In M. longifolia, the occurrence of the monoterpene piperitenone oxide was found to be toxic and associated with insect death. The results of this work show that high throughput techniques such as HS-SPME and GC×GC-qMS fingerprint analysis are ideal tools to analyze complex volatile matrices, and provide a sensitive method for the direct comparison and chemical visualization of plant and insect emitted volatile components.

  18. Polypyrrole/montmorillonite nanocomposite as a new solid phase microextraction fiber combined with gas chromatography–corona discharge ion mobility spectrometry for the simultaneous determination of diazinon and fenthion organophosphorus pesticides

    International Nuclear Information System (INIS)

    Jafari, Mohammad T.; Saraji, Mohammad; Sherafatmand, Hossein

    2014-01-01

    Graphical abstract: - Highlights: • A novel SPME fiber based on polypyrrole/montmorillonite nanocomposites with highly porous and thermal stability was prepared. • The two-dimensional separation technique, GC–IMS, was used for analysis of complex matrices extracted by SPME. • Direct and simultaneous analysis of diazinon and fenthion in various real samples was successfully accomplished. - Abstract: A novel solid phase microextraction (SPME) fiber was prepared and coupled with gas chromatography corona discharge ion mobility spectrometry (GC–CD–IMS) based on polypyrrole/montmorillonite nanocomposites for the simultaneous determination of diazinon and fenthion. The nanocomposite polymer was coated using a three-electrode electrochemical system and directly deposited on a Ni–Cr wire by applying a constant potential. The scanning electron microscopy images revealed that the new fiber exhibited a rather porous and homogenous surface. The thermal stability of the fabricated fiber was investigated by thermogravimetric analysis. The effects of different parameters influencing the extraction efficiency such as extraction temperature and time, salt addition, stirring rate, the amount of nanoclay, and desorption temperature were investigated and optimized. The method was exhaustively evaluated in terms of sensitivity, recovery, and reproducibility. The linearity ranges of 0.05–10 and 0.08–10 μg L −1 , and the detection limits of 0.020 and 0.035 μg L −1 were obtained for diazinon and fenthion, respectively. The relative standard deviation values were calculated to be lower than 5% and 8% for intra-day and inter-day, respectively. Finally, the developed method was applied to determine the diazinon and fenthion (as model compounds) in cucumber, lettuce, apple, tap and river water samples. The satisfactory recoveries revealed the capability of the two-dimensional separation technique (retention time in GC and drift time in IMS) for the analysis of complex

  19. Chlorophenol's ultra-trace analysis in environmental samples by chitosan-zinc oxide nanorod composite as a novel coating for solid phase micro-extraction combined with high performance liquid chromatography.

    Science.gov (United States)

    Alizadeh, Reza

    2016-01-01

    In this study, a simple, novel, and efficient preconcentration method has been developed for the determination of some chlorophenols (4-chlorophenol, 2,5-dichlorophenol, 2,3-dichlorophenol, and 2,4,6-trichlorophenol) using a direct solid phase microextraction (D-SPME) based on chitosan-ZnO nanorod composite combined with high performance liquid chromatography (HPLC). A one step-novel hydrothermal method was demonstrated on the fabrication of ZnO nanorods arrayed on the fused silica fiber in the chitosan hydrogel solution (CZNC) as a new coating of SPME fiber. The coating was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) instruments. The CZNC coating has combined the merits of both ZnO nanorods and chitosan hydrogel; it has several improvements such as increased extraction efficiency of chlorophenols and longer life time (over 80 cycles of D-SPME-HPLC operation). Experimental design method was used for optimization of extraction conditions and determination of four chlorophenols in water samples by SPME-HPLC-UV method. The calibration curves were linear from 5 to 1000 µg L(-1) for analytes, and the limits of detection were between 0.1 and 2 µg L(-1). Single fiber repeatability and fiber-to-fiber reproducibility were in the range of 5.8-10.2% and 8.8-14.5%, respectively. The spiked recoveries at 50 µg L(-1) for environmental water sample were in the range of 93-102%. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. N-Acyliminium Intermediates in Solid-Phase Synthesis

    DEFF Research Database (Denmark)

    Quement, Sebastian Thordal le; Petersen, Rico; Meldal, M.

    2010-01-01

    N-Acyliminium ions are powerful intermediates in synthetic organic chemistry. Examples of their use are numerous in solution-phase synthesis, but there are unmerited few reports on these highly reactive electrophiles in solid-phase synthesis. The present review covers the literature to date...

  1. Investigation of binary solid phases by calorimetry and kinetic modelling

    NARCIS (Netherlands)

    Matovic, M.

    2007-01-01

    The traditional methods for the determination of liquid-solid phase diagrams are based on the assumption that the overall equilibrium is established between the phases. However, the result of the crystallization of a liquid mixture will typically be a non-equilibrium or metastable state of the

  2. Phase transitions in crystalline solids 1

    International Nuclear Information System (INIS)

    Walker, J.R.

    1993-09-01

    Many crystalline materials of interest to the Canadian Nuclear Program have the potential to undergo phase transitions in their range of application. During such phase transitions, a representation of the space group of the higher symmetry polymorph softens to induce the transition. This report is the first in a series of reports concerned with the group-theoretic properties of phase transitions in crystalline materials. The object of the research is to identify all spectroscopically-active soft modes for the 230 three-dimensional space groups. Identification of these soft modes will enable a detailed examination of phase transitions in materials of interest to the Canadian Nuclear Program and aid in the optimization of material properties. In this report, the group-theoretic properties of crystal structures and phase transitions are reviewed. It is demonstrated that the problem of extending a group reduces to that of determining its automorphisms. The automorphism groups of the crystallographic and icosahedral point groups are derived using a consistent presentation

  3. Heterogeneous Ferroelectric Solid Solutions Phases and Domain States

    CERN Document Server

    Topolov, Vitaly

    2012-01-01

    The book deals with perovskite-type ferroelectric solid solutions for modern materials science and applications, solving problems of complicated heterophase/domain structures near the morphotropic phase boundary and applications to various systems with morphotropic phases. In this book domain state–interface diagrams are presented for the interpretation of heterophase states in perovskite-type ferroelectric solid solutions. It allows to describe the stress relief in the presence of polydomain phases, the behavior of unit-cell parameters of coexisting phases and the effect of external electric fields. The novelty of the book consists in (i) the first systematization of data about heterophase states and their evolution in ferroelectric solid solutions (ii) the general interpretation of heterophase and domain structures at changing temperature, composition or electric field (iii) the complete analysis of interconnection domain structures, unit-cell parameters changes, heterophase structures and stress relief.

  4. Development of a dynamic headspace solid-phase microextraction procedure coupled to GC-qMSD for evaluation the chemical profile in alcoholic beverages

    International Nuclear Information System (INIS)

    Rodrigues, F.; Caldeira, M.; Camara, J.S.

    2008-01-01

    In the present study, a simple and sensitive methodology based on dynamic headspace solid-phase microextraction (HS-SPME) followed by thermal desorption gas chromatography with quadrupole mass detection (GC-qMSD), was developed and optimized for the determination of volatile (VOCs) and semi-volatile (SVOCs) compounds from different alcoholic beverages: wine, beer and whisky. Key experimental factors influencing the equilibrium of the VOCs and SVOCs between the sample and the SPME fibre, as the type of fibre coating, extraction time and temperature, sample stirring and ionic strength, were optimized. The performance of five commercially available SPME fibres was evaluated and compared, namely polydimethylsiloxane (PDMS, 100 μm); polyacrylate (PA, 85 μm); polydimethylsiloxane/divinylbenzene (PDMS/DVB, 65 μm); carboxen TM /polydimethylsiloxane (CAR/PDMS, 75 μm) and the divinylbenzene/carboxen on polydimethylsiloxane (DVB/CAR/PDMS, 50/30 μm) (StableFlex). An objective comparison among different alcoholic beverages has been established in terms of qualitative and semi-quantitative differences on volatile and semi-volatile compounds. These compounds belong to several chemical families, including higher alcohols, ethyl esters, fatty acids, higher alcohol acetates, isoamyl esters, carbonyl compounds, furanic compounds, terpenoids, C13-norisoprenoids and volatile phenols. The optimized extraction conditions and GC-qMSD, lead to the successful identification of 44 compounds in white wines, 64 in beers and 104 in whiskys. Some of these compounds were found in all of the examined beverage samples. The main components of the HS-SPME found in white wines were ethyl octanoate (46.9%), ethyl decanoate (30.3%), ethyl 9-decenoate (10.7%), ethyl hexanoate (3.1%), and isoamyl octanoate (2.7%). As for beers, the major compounds were isoamyl alcohol (11.5%), ethyl octanoate (9.1%), isoamyl acetate (8.2%), 2-ethyl-1-hexanol (5.9%), and octanoic acid (5.5%). Ethyl decanoate (58

  5. The Structural Phase Transition in Solid DCN

    DEFF Research Database (Denmark)

    Dietrich, O. W.; Mackenzie, Gordon A.; Pawley, G. S.

    1976-01-01

    Neutron scattering measurements on deuterated hydrogen cyanide have shown that the structural phase transition from a tetragonal to an orthorhombic form at 160 K is a first order transition. A transverse acoustic phonon mode, which has the symmetry of the transition was observed at very low...

  6. Ordered mesoporous carbon film as an effective solid-phase microextraction coating for determination of benzene series from aqueous media

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Hui [Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); School of Geography Science, Nantong University, Nantong 226001 (China); Li, Jiansheng, E-mail: lijsh@mail.njust.edu.cn [Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); Jiang, Mingyue; Lu, Rui; Shen, Jinyou; Sun, Xiuyun; Han, Weiqing [Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China); Wang, Lianjun, E-mail: wanglj@mail.njust.edu.cn [Jiangsu Key Laboratory of Chemical Pollution Control and Resources Reuse, School of Environmental Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China)

    2015-08-12

    The present work reports preparation of ordered mesoporous carbon (OMC) film supported on a graphite fiber as a new type of solid-phase microextraction (SPME) fiber for determination of benzene series from aqueous media. The strategy for the supported OMC film preparation was combined dip-coating technology with solvent evaporation-induced self-assembly (EISA) approach. A graphite fiber was immersed in an ethanol solution containing phenolic resin and Pluronic triblock copolymer. Upon solvent evaporation and subsequent pyrolysis under 700 °C, the phenolic resin and the surfactant self-assembled on the surface of the graphite fiber to form smooth OMC film. X-ray diffraction (XRD), transmission electron microscopy (TEM) and nitrogen isothermal adsorption results indicate that the resultant OMC film possesses well-ordered two dimensional hexagonal mesostructure with pore diameters of 4.5 nm and BET surfaces of 630 m{sup 2}/g. Scanning electron microscopy (SEM) studies show the supported OMC film with thickness at 8.5 μm is continuous and defect-free. The SPME efficiency of the OMC fiber was evaluated by analysis of five benzene series (benzene, toluene, ethylbenzene, p-xylene and m-xylene) from water samples by gas chromatography-flame ionization detection (GC-FID). The analysis results indicate that the prepared OMC fiber has wide linear ranges (0.5–500 μg/L), low detection limits (0.01–0.05 μg/L) and good repeatabilities (4.0–5.8% for one fiber, 2.9–8.7% for fiber-to-fiber). Compared with commercial counterparts, the OMC fiber exhibits improved extraction efficiency for benzene series and PAHs. - Highlights: • Ordered mesoporous carbon film supported on graphite fiber was first reported as solid-phase microextraction coating. • The strategy for the film preparation was combined dip-coating technology with evaporation-induced self-assembly approach. • The obtained fiber showed enhanced thermal stability and organic solvents resistance. • The

  7. Analysis of heterocyclic amines in hair by on-line in-tube solid-phase microextraction coupled with liquid chromatography−tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kataoka, Hiroyuki, E-mail: hkataoka@shujitsu.ac.jp; Inoue, Tsutomu; Saito, Keita; Kato, Hisato; Masuda, Kazufumi

    2013-07-05

    Graphical abstract: Mutagenic and carcinogenic heterocyclic amines are accumulated in the hair of smoker. -- Highlights: •On-line in-tube solid-phase microextraction of heterocyclic amines was optimized. •Fourteen heterocyclic amines were simultaneously determined by LC–MS/MS. •Pico gram levels of heterocyclic amines could be easily analyzed within 15 min. •Heterocyclic amines could be quantitatively analyzed from several milligrams of hair. •The method is useful for the assessment of long-term exposure to heterocyclic amines. -- Abstract: Mutagenic and carcinogenic heterocyclic amines (HCAs) are formed during heating of various proteinaceous foods, but human exposure to HCAs has not yet been elucidated in detail. To assess long-term exposure to HCAs, we developed a simple and sensitive method for measuring HCAs in hair by automated on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS). Using a Zorbax Eclipse XDB-C8 column, 16 HCAs were analyzed within 15 min. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL sample at a flow rate of 200 μL min{sup −1} using a Supel-Q PLOT capillary column as an extraction device. The extracted HCAs were easily desorbed from the column by passage of the mobile phase, with no carryover observed. This in-tube SPME LC–MS/MS method showed good linearity for HCAs in the range of 10–2000 pg mL{sup −1}, with correlation coefficients above 0.9989 (n = 18), using stable isotope-labeled HCA internal standards. The detection limits (S/N = 3) of 14 HCAs except for MeAαC and Glu-P-1 were 0.10–0.79 pg mL{sup −1}. This method was successfully utilized to analyze 14 HCAs in hair samples without any interference peaks, with quantitative limits (S/N = 10) of about 0.17–1.32 pg mg{sup −1} hair. Using this method, we evaluated the exposure to HCAs in cigarette smoke and the suitability of using hair HCAs as exposure biomarkers.

  8. Analysis of heterocyclic amines in hair by on-line in-tube solid-phase microextraction coupled with liquid chromatography−tandem mass spectrometry

    International Nuclear Information System (INIS)

    Kataoka, Hiroyuki; Inoue, Tsutomu; Saito, Keita; Kato, Hisato; Masuda, Kazufumi

    2013-01-01

    Graphical abstract: Mutagenic and carcinogenic heterocyclic amines are accumulated in the hair of smoker. -- Highlights: •On-line in-tube solid-phase microextraction of heterocyclic amines was optimized. •Fourteen heterocyclic amines were simultaneously determined by LC–MS/MS. •Pico gram levels of heterocyclic amines could be easily analyzed within 15 min. •Heterocyclic amines could be quantitatively analyzed from several milligrams of hair. •The method is useful for the assessment of long-term exposure to heterocyclic amines. -- Abstract: Mutagenic and carcinogenic heterocyclic amines (HCAs) are formed during heating of various proteinaceous foods, but human exposure to HCAs has not yet been elucidated in detail. To assess long-term exposure to HCAs, we developed a simple and sensitive method for measuring HCAs in hair by automated on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS). Using a Zorbax Eclipse XDB-C8 column, 16 HCAs were analyzed within 15 min. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL sample at a flow rate of 200 μL min −1 using a Supel-Q PLOT capillary column as an extraction device. The extracted HCAs were easily desorbed from the column by passage of the mobile phase, with no carryover observed. This in-tube SPME LC–MS/MS method showed good linearity for HCAs in the range of 10–2000 pg mL −1 , with correlation coefficients above 0.9989 (n = 18), using stable isotope-labeled HCA internal standards. The detection limits (S/N = 3) of 14 HCAs except for MeAαC and Glu-P-1 were 0.10–0.79 pg mL −1 . This method was successfully utilized to analyze 14 HCAs in hair samples without any interference peaks, with quantitative limits (S/N = 10) of about 0.17–1.32 pg mg −1 hair. Using this method, we evaluated the exposure to HCAs in cigarette smoke and the suitability of using hair HCAs as exposure biomarkers

  9. Quantification of Polyfunctional Thiols in Wine by HS-SPME-GC-MS Following Extractive Alkylation

    Directory of Open Access Journals (Sweden)

    Lauren E. Musumeci

    2015-07-01

    Full Text Available Analyses of key odorous polyfunctional volatile thiols in wines (3-mercaptohexanol (3-MH, 3-mercaptohexylacetate (3-MHA, and 4-mercapto-4-methyl-2-pentanone (4-MMP are challenging due to their high reactivity and ultra-trace concentrations, especially when using conventional gas-chromatography electron impact mass spectrometry (GC-EI-MS. We describe a method in which thiols are converted to pentafluorobenzyl (PFB derivatives by extractive alkylation and the organic layer is evaporated prior to headspace solid phase microextraction (HS-SPME and GC-EI-MS analysis. Optimal parameters were determined by response surface area modeling. The addition of NaCl solution to the dried SPME vials prior to extraction resulted in up to less than fivefold improvement in detection limits. Using 40 mL wine samples, limits of detection for 4-MMP, 3-MH, and 3-MHA were 0.9 ng/L, 1 ng/L, and 17 ng/L, respectively. Good recovery (90%–109% and precision (5%–11% RSD were achieved in wine matrices. The new method was used to survey polyfunctional thiol concentrations in 61 commercial California and New York State wines produced from V. vinifera (Riesling, Gewürztraminer, Cabernet Sauvignon, Sauvignon blanc and non-varietal rosé wines, V. labruscana (Niagara, and Vitis spp. (Cayuga White. Mean 4-MMP concentrations in New York Niagara (17 ng/L were not significantly different from concentrations in Sauvignon blanc, but were significantly higher than 4-MMP in other varietal wines.

  10. Phase coexistence in ferroelectric solid solutions: Formation of monoclinic phase with enhanced piezoelectricity

    Directory of Open Access Journals (Sweden)

    Xiaoyan Lu

    2016-10-01

    Full Text Available Phase morphology and corresponding piezoelectricity in ferroelectric solid solutions were studied by using a phenomenological theory with the consideration of phase coexistence. Results have shown that phases with similar energy potentials can coexist, thus induce interfacial stresses which lead to the formation of adaptive monoclinic phases. A new tetragonal-like monoclinic to rhombohedral-like monoclinic phase transition was predicted in a shear stress state. Enhanced piezoelectricity can be achieved by manipulating the stress state close to a critical stress field. Phase coexistence is universal in ferroelectric solid solutions and may provide a way to optimize ultra-fine structures and proper stress states to achieve ultrahigh piezoelectricity.

  11. Surface phase transitions in cu-based solid solutions

    Science.gov (United States)

    Zhevnenko, S. N.; Chernyshikhin, S. V.

    2017-11-01

    We have measured surface energy in two-component Cu-based systems in H2 + Ar gas atmosphere. The experiments on solid Cu [Ag] and Cu [Co] solutions show presence of phase transitions on the surfaces. Isotherms of the surface energy have singularities (the minimum in the case of copper solid solutions with silver and the maximum in the case of solid solutions with cobalt). In both cases, the surface phase transitions cause deficiency of surface miscibility: formation of a monolayer (multilayer) (Cu-Ag) or of nanoscale particles (Cu-Co). At the same time, according to the volume phase diagrams, the concentration and temperature of the surface phase transitions correspond to the solid solution within the volume. The method permits determining the rate of diffusional creep in addition to the surface energy. The temperature and concentration dependence of the solid solutions' viscosity coefficient supports the fact of the surface phase transitions and provides insights into the diffusion properties of the transforming surfaces.

  12. Determination of Pyrethroids in Tea Brew by GC-MS Combined with SPME with Multiwalled Carbon Nanotube Coated Fiber

    Directory of Open Access Journals (Sweden)

    Dongxia Ren

    2018-01-01

    Full Text Available A new method has been developed to simultaneously determine 7 pyrethroid residues in tea brew using gas chromatography-mass spectrometry (GC-MS combined with solid phase microextraction (SPME with multiwalled carbon nanotubes (MWCNTs coated fiber. The MWCNTs coated fiber of SPME was homemade by using stainless steel wire as coating carrier and polyacrylonitrile (PAN solution as adhesive glue. Under the optimized conditions, a good linearity was shown for bifenthrin, fenpropathrin, permethrin, and cyfluthrin in 1–50 ng mL−1 and for cypermethrin, fenvalerate, and deltamethrin in 5–50 ng mL−1. The correlation coefficients were in the range of 0.9948–0.9999. The average recoveries of 7 pyrethroids were 94.2%–107.3% and the relative standard deviations (RSDs were less than 15%. The detection limit of the method ranged from 0.12 to 1.65 ng mL−1. The tea brew samples made from some commercial tea samples were analyzed. Among them, bifenthrin, fenpropathrin, and permethrin were found. The results show that the method is rapid and sensitive and requires low organic reagent consumption, which can be well used for the detection of the pyrethroids in tea brew.

  13. Partitioning of the pesticide trifluralin between dissolved organic matter and water using automated SPME-GC/MS

    KAUST Repository

    Caupos, Emilie

    2014-10-04

    Solid-phase microextraction (SPME) was used to determine the equilibrium association constant for a pesticide, trifluralin (TFR), with dissolved organic matter (DOM). After optimization of the SPME method for the analysis of TFR, partition coefficients (K DOM) with three different sources of DOM were determined in buffered solutions at pH 7. Commercial humic acids and DOM fractions isolated from two surface waters were used. The values of log K DOMvaried from 4.3 to 5.8, depending on the nature of the organic material. A good correlation was established between log K DOMand DOM properties (as measured with the H/O atomic ratio and UV absorbance), in agreement with literature data. This is consistent with the effect of polarity and aromaticity for governing DOM-pollutant associations, regardless of the origin of DOM. This association phenomenon is relevant to better understand the behavior of pesticides in the environment since it controls part of pesticide leaching and fate in aquatic systems.

  14. Characterisation of the volatile profile of coconut water from five varieties using an optimised HS-SPME-GC analysis.

    Science.gov (United States)

    Prades, Alexia; Assa, Rebecca Rachel Ablan; Dornier, Manuel; Pain, Jean-Pierre; Boulanger, Renaud

    2012-09-01

    Coconut (Cocos nucifera L.) water is a refreshing tropical drink whose international market has recently been growing. However, little is yet known about its physicochemical composition, particularly its aroma. This study set out to characterise the volatile profile of water from five coconut varieties. Aroma compounds were characterised by headspace solid phase microextraction gas chromatography (HS-SPME-GC) analysis. An experimental design was established to optimise SPME conditions, leading to an equilibration time of 10 min followed by an extraction time of 60 min at 50 °C. Accordingly, immature coconut water from WAT (West African Tall), PB121 (MYD × WAT Hybrid), MYD (Malayan Yellow Dwarf), EGD (Equatorial Guinea Green Dwarf) and THD (Thailand Aromatic Green Dwarf) palms was analysed and described. Ketones were mainly present in the Tall and Hybrid varieties, whereas aldehydes were most abundant in the Dwarf palms. Tall coconut water was characterised by a high lactone content. THD exhibited a high ethyl octanoate level. The cluster analysis of the volatile fraction from the five coconut cultivars was found to be related to their genetic classification. The volatile compounds of immature coconut water from five varieties were characterised for the first time. Volatile profile analysis could be a useful tool for the selection of Dwarf coconut varieties, which are mainly consumed as a beverage. Copyright © 2012 Society of Chemical Industry.

  15. Passive Sampling and Analysis of Naphthalene in Internal Combustion Engine Exhaust with Retracted SPME Device and GC-MS

    Directory of Open Access Journals (Sweden)

    Nassiba Baimatova

    2017-07-01

    Full Text Available Exhaust gases from internal combustion engines are the main source of urban air pollution. Quantification of Polycyclic aromatic hydrocarbons (PAHs in the exhaust gases is needed for emissions monitoring, enforcement, development, and testing of control technologies. The objective was to develop quantification of gaseous naphthalene in diesel engine exhaust based on diffusion-controlled extraction onto a retracted solid-phase microextraction (SPME fiber coating and analysis on gas chromatography-mass spectrometry (GC-MS. Extraction of naphthalene with retracted fibers followed Fick’s law of diffusion. Extracted mass of naphthalene was proportional to Cg, t, Dg, T and inversely proportional to Z. Method detection limit (p = 0.95 was 11.5 ppb (0.06 mg·m−3 at t = 9 h, Z = 10 mm and T = 40 °C, respectively. It was found that the % mass extracted of naphthalene by SPME needle assembly depended on the type of fiber. Storage time at different temperatures did not affect analyte losses extracted by polydimethylsiloxane (PDMS 100 µm fiber. The developed method was tested on exhaust gases from idling pickup truck and tractor, and compared side-by-side with a direct injection of sampled exhaust gas method. Time-weighted average (TWA concentrations of naphthalene in exhaust gases from idling pickup truck and a tractor ranged from 0.08 to 0.3 mg·m−3 (15.3–53.7 ppb.

  16. Stir bar sorptive extraction-gas chromatography-mass spectrometry analysis of tetramethylene disulfotetramine in food: Method development and comparison to solid-phase microextraction.

    Science.gov (United States)

    De Jager, Lowri S; Perfetti, Gracia A; Diachenko, Gregory W

    2009-03-09

    A stir bar sorptive extraction-gas chromatography-mass spectrometry (SBSE-GC-MS) method for the determination of tetramethylene disulfotetramine is presented. The limits of detection (LOD) of the optimized method was 0.2ngg(-1) for extractions from water and 0.3-2.1ngg(-1) for extractions from foods. Recovery was highly matrix dependent (36-130%) and quantification required standard addition calibrations. Standard addition calibration lines had high linearity (R(2)>0.97) and replicate extractions had good reproducibility (R.S.D.=4.4-9.8%). A comparison of the SBSE method and a previously developed headspace (HS)-solid-phase microextraction (SPME) method was performed. Generally, SBSE provided higher sensitivity with decreased analysis time.

  17. Determination of 5-hydroxymethylfurfural in honey, using headspace-solid-phase microextraction coupled with a polyoxometalate-coated piezoelectric quartz crystal.

    Science.gov (United States)

    Veríssimo, Marta I S; Gamelas, José A F; Evtuguin, Dmitry V; Gomes, M Teresa S R

    2017-04-01

    High concentrations of 5-hydroxymethylfurfural (HMF) in honey provide an indication of overheating under inappropriate storage conditions or aging. Conventional methods for determining HMF are cumbersome and require expensive equipment or hazardous reagents. Hence the aim of this study was to propose a new analytical tool for HMF determination in honey, using a low cost acoustic wave sensor. Volatile organic compounds (VOCs) of honey samples were extracted, using the solid phase microextraction (SPME) technique, and HMF was quantified, using a piezoelectric quartz crystal with gold electrodes coated with a layer of decamolybdodivanado phosphoric acid, sensitive to HMF. The reliability of the proposed method was confirmed after comparing the results of HMF quantification with those obtained by the conventional spectrophotometric White method, and no statistical differences were found (α=0.05). Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Solid-phase synthesis of piperazinones via disrupted Ugi condensation.

    Science.gov (United States)

    Treder, Adam P; Tremblay, Marie-Claude; Yudin, Andrei K; Marsault, Eric

    2014-09-05

    The first application of aziridine aldehyde dimers in solid-phase synthesis is reported. The solid-supported disrupted Ugi condensation between an aziridine aldehyde dimer, isonitrile, and backbone-anchored amino acids delivered N-acyl aziridine intermediates, which were reacted with nucleophiles to yield the corresponding piperazinones. Subsequent cleavage from the resin provided a diverse set of 2,3,6-trisubstituted piperazinones starting from various amino acids, aziridine aldehydes, and nucleophiles.

  19. Nanostructured conducting molecularly imprinted polymer for selective extraction of salicylate from urine and serum samples by electrochemically controlled solid-phase micro-extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ameli, Akram [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Alizadeh, Naader, E-mail: alizaden@modares.ac.ir [Department of Chemistry, Faculty of Science, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of)

    2011-11-30

    Highlights: Black-Right-Pointing-Pointer Overoxidized polypyrrole templated with salicylate has been utilized as conducting molecular imprinted polymer for EC-SPME. Black-Right-Pointing-Pointer This first study reported on conducting molecular imprinted polymer was used to EC-SPME of salicylate. Black-Right-Pointing-Pointer Proposed method, is particularly effective in sample clean-up and selective monitoring of salicylate in physiological samples. - Abstract: Overoxidized polypyrrole (OPPy) films templated with salicylate (SA) have been utilized as conducting molecular imprinted polymers (CMIPs) for potential-induced selective solid-phase micro-extraction processes. Various important fabrication factors for controlling the performance of the OPPy films have been investigated using fluorescence spectrometry. Several key parameters such as applied potential for uptake, release, pH of uptake and release solution were varied to achieve the optimum micro-extraction procedure. The film template with SA exhibited excellent selectivity over some interference. The calibration graphs were linear in the ranges of 5 Multiplication-Sign 10{sup -8} to 5 Multiplication-Sign 10{sup -4} and 1.2 Multiplication-Sign 10{sup -6} to 5 Multiplication-Sign 10{sup -4} mol mL{sup -1} and the detection limit was 4 Multiplication-Sign 10{sup -8} mol L{sup -1}. The OPPy film as the solid-phase micro-extraction absorbent has been applied for the selective clean-up and quantification of trace amounts of SA from physiological samples. The results of scanning electron microscopy (SEM) have confirmed the nano-structure morphologies of the films.

  20. Combinatorial solid-phase synthesis of hapalosin mimetics

    DEFF Research Database (Denmark)

    Olsen, Jacob A.; Jensen, Knud J.; Nielsen, John

    2000-01-01

    The solid-phase synthesis of a small library of mimetics of the cyclic depsipeptide hapalosin is described. 3-Amino-4-hydroxy-5-nitrobenzoic acid was anchored through the anilino moiety to a backbone amide linker (BAL) handle support. Using chemoselective reactions and without the need for protec......The solid-phase synthesis of a small library of mimetics of the cyclic depsipeptide hapalosin is described. 3-Amino-4-hydroxy-5-nitrobenzoic acid was anchored through the anilino moiety to a backbone amide linker (BAL) handle support. Using chemoselective reactions and without the need...

  1. Solid-phase synthesis of complex and pharmacologically interesting heterocycles

    DEFF Research Database (Denmark)

    Nielsen, Thomas Eiland

    2009-01-01

    with significant structural complexity and diversity. This review describes some of the most systematic solid-phase approaches that are potentially suited for pharmaceutical applications, that is, the methods described are useful for the synthesis of compound collections, and exhibit tunable stereochemistry......Efficient routes for the creation of heterocycles continue to be one of the primary goals for solid-phase synthesis. Recent advances in this field rely most notably on transition-metal-catalysis and N-acyliminium chemistry to mediate a range of cyclization processes for the generation of compounds...

  2. On-line electrochemically controlled in-tube solid phase microextraction of inorganic selenium followed by hydride generation atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Asiabi, Hamid [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Yamini, Yadollah, E-mail: yyamini@modares.ac.ir [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Seidi, Shahram [Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of); Shamsayei, Maryam; Safari, Meysam; Rezaei, Fatemeh [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of)

    2016-05-30

    In this work, for the first time, a rapid, simple and sensitive microextraction procedure is demonstrated for the matrix separation, preconcentration and determination of inorganic selenium species in water samples using an electrochemically controlled in-tube solid phase microextraction (EC-in-tube SPME) followed by hydride generation atomic absorption spectrometry (HG-AAS). In this approach, in which EC-in-tube SPME and HG-AAS system were combined, the total analysis time, was decreased and the accuracy, repeatability and sensitivity were increased. In addition, to increases extraction efficiency, a novel nanostructured composite coating consisting of polypyrrole (PPy) doped with ethyleneglycol dimethacrylate (EGDMA) was prepared on the inner surface of a stainless-steel tube by a facile electrodeposition method. To evaluate the offered setup and the new PPy-EGDMA coating, it was used to extract inorganic selenium species in water samples. Extraction of inorganic selenium species was carried out by applying a positive potential through the inner surface of coated in-tube under flow conditions. Under the optimized conditions, selenium was detected in amounts as small as 4.0 parts per trillion. The method showed good linearity in the range of 0.012–200 ng mL{sup −1}, with coefficients of determination better than 0.9996. The intra- and inter-assay precisions (RSD%, n = 5) were in the range of 2.0–2.5% and 2.7–3.2%, respectively. The validated method was successfully applied for the analysis of inorganic selenium species in some water samples and satisfactory results were obtained. - Graphical abstract: An electrochemically controlled in-tube solid phase microextraction followed by hydride generation atomic absorption spectrometry was developed for extraction and determination ultra-trace amounts of Se in aqueous solutions. - Highlights: • A nanostructured composite coating consisting of PPy doped with EGDMA was prepared. • The coating was

  3. Solid-phase synthesis of multivalent metal phosphates

    International Nuclear Information System (INIS)

    Konstant, Z.A.

    1984-01-01

    Some multivalent metals (Mg, Zn, Mn, Co, Ni, Sc, Ti, V, Cr, Fe, Ce) are used as examples for considering certain general problems (mechanism, phase formation) of solid-phase synthesis of phosphates from metal oxides and ammonium dihydrophosphate (t=200-1500 deg C). It is noted that the observed phenomena, such as parallel reactionS, formation of several modifications of one compound is characteristic of solid-phase synthesis of condensed phosphates when condensation is determined by the metal-phosphorus ratio, potential cation coordination and thermodynamic characteristics of polymers being prepared. The possibility of oxidation-reduction reactions with multiple changes in the valence of elements is also very important. Complex schemes of interactions, phase diagrams of the systems are presented

  4. Analytical study of solids-gas two phase flow

    International Nuclear Information System (INIS)

    Hosaka, Minoru

    1977-01-01

    Fundamental studies were made on the hydrodynamics of solids-gas two-phase suspension flow, in which very small solid particles are mixed in a gas flow to enhance the heat transfer characteristics of gas cooled high temperature reactors. Especially, the pressure drop due to friction and the density distribution of solid particles are theoretically analyzed. The friction pressure drop of two-phase flow was analyzed based on the analytical result of the single-phase friction pressure drop. The calculated values of solid/gas friction factor as a function of solid/gas mass loading are compared with experimental results. Comparisons are made for Various combinations of Reynolds number and particle size. As for the particle density distribution, some factors affecting the non-uniformity of distribution were considered. The minimum of energy dispersion was obtained with the variational principle. The suspension density of particles was obtained as a function of relative distance from wall and was compared with experimental results. It is concluded that the distribution is much affected by the particle size and that the smaller particles are apt to gather near the wall. (Aoki, K.)

  5. Solid-phase synthesis of complex and pharmacologically interesting heterocycles

    DEFF Research Database (Denmark)

    Nielsen, Thomas Eiland

    2009-01-01

    with significant structural complexity and diversity. This review describes some of the most systematic solid-phase approaches that are potentially suited for pharmaceutical applications, that is, the methods described are useful for the synthesis of compound collections, and exhibit tunable stereochemistry...

  6. Solid Phase Characterization of Tank 241-C-105 Grab Samples

    Energy Technology Data Exchange (ETDEWEB)

    Ely, T. M. [Washington River Protection Solutions LLC, Richland, WA (United States); LaMothe, M. E. [Washington River Protection Solutions LLC, Richland, WA (United States); Lachut, J. S. [Washington River Protection Solutions LLC, Richland, WA (United States)

    2016-01-11

    The solid phase characterization (SPC) of three grab samples from single-shell Tank 241-C-105 (C-105) that were received at the laboratory the week of October 26, 2015, has been completed. The three samples were received and broken down in the 11A hot cells.

  7. Insight into solid-liquid phase transfer catalyzed synthesis of ...

    Indian Academy of Sciences (India)

    Ganapati D Yadav

    2017-11-16

    Nov 16, 2017 ... https://doi.org/10.1007/s12039-017-1368-1. REGULAR ARTICLE. Special Issue on Recent Trends in the Design and Development of Catalysts and their Applications. Insight into solid-liquid phase transfer catalyzed synthesis of. Mecoprop ester using K2CO3 as base and development of new kinetic model ...

  8. Extraction of Pesticides from Plants using Solid Phase ...

    African Journals Online (AJOL)

    NICO

    Extraction of Pesticides from Plants using Solid Phase. Microextraction and QuEChERS. Veronica C. Obusenga*, Beauty M. Mookantsaa, Harriet Okatcha,. Ketlhatlogile Mosepeleb and NelsonTortoc. aDepartment of Chemistry. University of Botswana, Private Bag UB 00704, Gaborone, Botswana. bUniversity of Botswana ...

  9. Solid-phase oligosaccharide and glycopeptide synthesis using glycosynthases

    DEFF Research Database (Denmark)

    Tolborg, Jakob Fjord; Petersen, Lars; Jensen, Knud Jørgen

    2002-01-01

    and the prospect of automatability. Here, we report the first application of glycosynthases to solid-phase oligosaccharide synthesis by use of the 51 kDa serine and glycine mutants of Agrobacterium sp. beta-glucosidase, Abg E358S and E358G. Acceptors were linked to PEGA resin through a backbone amide linker (BAL...

  10. Solid phase extraction method for determination of mitragynine in ...

    African Journals Online (AJOL)

    performance liquid chromatography–tandem mass spectrometry for the blood quantification of thirty-four toxic principles of plant origin. Application to forensic toxicology. J Chromatogr B 2015; 975: 65-76. 16. Żwir-Ferenc A, Biziuk M. Solid phase extraction technique - Trends, opportunities and applications. Polish J Environ ...

  11. after solid phase extraction on modified sawdust s

    African Journals Online (AJOL)

    Preferred Customer

    detection limit and selectivity [1]. Various methods have been used for the ..... The equation of the line was A = 0.0098C + 0.0022 with a regression coefficient of r = 0.9977 (n = 10). The limit of ... In order to evaluate the selectivity of the method, the effects of different ions on the solid phase extraction and determination of ...

  12. A solid-phase-radioimmunoassay for total serum thyroxine

    International Nuclear Information System (INIS)

    Moedder, G.; Sokolowski, G.

    1978-01-01

    A new solid phase radioimmunoassay for total serum thyroxine was evaluated over a longer time under clinical routine conditions and compared with an established test system. The results show up that the T 4 values are precise, reliable and reproducible, the is incomplicate to handle and well suitable for semiautomatic pipetting systems. (orig.) 891 MG [de

  13. Kinetics of solid state phase transformations: Measurement and ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 122; Issue 1. Kinetics of solid state phase transformations: Measurement and modelling of some basic issues. S Raju E ... are enumerated. A simple and general modelling methodology for understanding the kinetics of non-isothermal transformations is outlined.

  14. Solid-phase synthesis of 3-amino-2-pyrazolines

    DEFF Research Database (Denmark)

    Nielsen, John

    1998-01-01

    The development of a solid-phase synthesis of 3-amino-2-pyrazolines is described. Conjugate addition of hydrazines to alpha,beta-unsaturated nitriles followed by cyclization yields 3-amino-2-pyrazolines. Acylation or sulfonation of the free amino-group yields a 24 member library of 3-amino-2...

  15. Solid-phase synthesis of 3-amino-2-pyrazolines

    DEFF Research Database (Denmark)

    Lyngsø, Lars O.; Nielsen, John

    1998-01-01

    The development of a solid-phase synthesis of 3-amino-2-pyrazolines is described. Conjugate addition of hydrazines to α,β-unsaturated nitriles followed by cyclization yields 3-amino-2-pyrazolines. Acylation or sulfonation of the free amino-group yields a 24 member library of 3-amino-2- pyrazolines....

  16. Determination of 8 Synthetic Food Dyes by Solid Phase Extraction ...

    African Journals Online (AJOL)

    Recovery was 94.2 % for Brilliant blue in jelly powder. Conclusion: This method was successfully applied to determine colorants in various (30) water-soluble foods, including fruit flavored drinks, sugar confectionery, sweets, etc. Keywords: Synthetic colors, Food, Fruit flavored drinks, Solid phase extraction, RP-HPLC ...

  17. Development of headspace solid-phase microextraction method for ...

    African Journals Online (AJOL)

    ... analysis of 14 multiclass pesticide residues in fruits and vegetable samples. The gas chromatography mass spectrometry parameters (desorption temperature and time, column flow rate, interface temperature) and solid phase microextraction parameters (fiber coating type, extraction temperature and time, pH, salt addition ...

  18. Insight into solid-liquid phase transfer catalyzed synthesis of ...

    Indian Academy of Sciences (India)

    2-Methyl-4-chlorophenoxy propionic acid (Mecoprop) is a widely used household herbicide. In the current work, a simple synthetic method is developed for Mecoprop methyl ester using solid-liquid phase transfer catalysis (S-L PTC) with K₂CO₃ as mild base and toluene as solvent. Conversion of 95% was achieved with ...

  19. Solid phase separation technique for use in radioimmunoassays

    International Nuclear Information System (INIS)

    Tu, J.I.

    1979-01-01

    A radioimmunoassay procedure, and article of manufacture for carrying out that procedure, are disclosed herein. The solid phase separation technique utilized in the radioimmunoassay of this invention utilizes a test tube, the internal surface of which has been coated with two antibody layers

  20. Solid-Phase Extraction Combined with High Performance Liquid ...

    African Journals Online (AJOL)

    Methods: Solid-phase extraction method was employed for the extraction of the estrogen from milk and high performance liquid chromatography-diode array detector (HPLC-DAD) was used for the determination of estrogen. Results: Optimal chromatographic conditions were achieved on an Eclipse XDB-C18 column at a ...

  1. Analysis of urinary 8-isoprostane as an oxidative stress biomarker by stable isotope dilution using automated online in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Mizuno, Keisuke; Kataoka, Hiroyuki

    2015-08-10

    We have developed a simple and sensitive method for the determination of the oxidative stress biomarker 8-isoprostane (8-IP) in human urine by automated online in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) using a Zorbax Eclipse XDB-8 column and 0.1% formic acid/methanol (25/75, v/v) as a mobile phase. Electrospray MS/MS for 8-IP was performed on an API 4000 triple quadruple mass spectrometer in negative ion mode. The optimum in-tube SPME conditions were 20 draw/eject cycles with a sample size of 40 μL using a Carboxen 1006 PLOT capillary column for the extraction. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Total analysis time of this method including online extraction and analysis was about 30 min for each sample. The in-tube SPME LC-MS/MS method showed good linearity in the concentration range of 20-1000 pg/mL with a correlation coefficient r = 0.9999 for 8-IP using a stable isotope-labeled internal standard, 8-IP-d4. The detection limit of 8-IP was 3.3 pg/mL and the proposed method showed 42-fold higher sensitivity than the direct injection method. The intra-day and inter-day precisions (relative standard deviations) were below 5.0% and 8.5% (n = 5), respectively. This method was applied successfully to the analysis of urine samples without pretreatment or interference peaks. The recovery rates of 8-IP spiked into urine samples were above 92%. This method is useful for assessing the effects of oxidative stress and antioxidant intake. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. The study of actinide solubility limiting solid phases

    International Nuclear Information System (INIS)

    Thomason, H.P.

    1988-01-01

    The literature has been surveyed for information on the identification and ageing of actinide solubility limiting solid phases. References include identification and ageing of actinide solids which do not necessarily relate to the control of solubility or the conditions found in the near-field of a repository. Methods which have been used to characterise actinide solids include X-ray diffraction, electron microscopy, Raman spectroscopy, X-ray photoelectron spectroscopy, electrochemistry and chemical analysis. The techniques most widely used are X-ray and electron diffraction. As well as characterisation, diffraction patterns have been used to monitor changes in the crystallinity of a solid with time. The ageing of alpha active actinide solids involves two conflicting processes. An amorphous actinide precipitate will, like most solids, become more crystalline with time. The recoil energy from the alpha decay of actinides will displace some of the atoms from their lattice sites and cause a decrease in crystallinity. The crystallinity of actinide solids affects solubility and is therefore an important parameter to study. Recommendations have been made for further environmental work. (author)

  3. Determination of anabolic steroids in human urine by automated in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Saito, Keita; Yagi, Katsuharu; Ishizaki, Atsushi; Kataoka, Hiroyuki

    2010-09-05

    A simple, rapid and sensitive method was developed for determining the presence of seven anabolic steroids (boldenone, nandrolone, testosterone, methyltestosterone, epiandrosterone, androsterone, and atnozolol) in human urine. Glucuronide-conjugates of these compounds were hydrolyzed with beta-glucuronidase. The anabolic steroids were analyzed by on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-mass spectrometry (LC-MS). The steroids were separated within 14 min by high performance liquid chromatography using a Chromolith RP-18e column and 5 mM ammonium formate/methanol (35/65, v/v) as a mobile phase at a flow rate of 1.0 mL/min. Electrospray ionization conditions in the positive ion mode were optimized for the MS detection of these compounds. The optimum in-tube SPME conditions were 20 draw/eject cycles with a sample size of 40 microL using a Supel-Q PLOT capillary column for the extraction. The extracted compounds could be desorbed readily from the capillary column by flow of the mobile phase, and no carryover was observed. Using the in-tube SPME LC-MS with SIM mode detection, good linearity of the calibration curve (r>0.995) was obtained in the concentration range of 0.5-20 ng/mL, except for stanozolol. The detection limits (S/N=3) of anabolic steroids were in the range 9-182 pg/mL and the proposed method showed 20-33-fold higher sensitivity than the direct injection method. The within-day and between-day precisions were below 4.0% and 7.3% (n=5), respectively. This method was applied successfully to the analysis of urine samples without the interference peaks. The recovery rates of anabolic steroids spiked into urine samples were above 85%. This method is useful to analyze the urinary levels of these compounds in anti-doping tests. 2010 Elsevier B.V. All rights reserved.

  4. Electropolymerized multiwalled carbon nanotubes/polypyrrole fiber for solid-phase microextraction and its applications in the determination of pyrethroids.

    Science.gov (United States)

    Chen, Liangbi; Chen, Wenfeng; Ma, Chunhua; Du, Dan; Chen, Xi

    2011-03-15

    A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes/polypyrrole (MWCNTs/Ppy) was prepared with an electrochemical method and used for the extraction of pyrethroids in natural water samples. The results showed that the MWCNTs/Ppy coated fiber had high organic stability, and remarkable acid and alkali resistance. In addition, the MWCNTs/Ppy coated fiber was more effective and superior to commercial PDMS and PDMS/DVD fibers in extracting pyrethroids in natural water samples. Under optimized conditions, the calibration curves were found to be linear from 0.001 to 10 μg mL(-1) for five of the six pyrethroids studied, the exception being fenvalerate (which was from 0.005 to 10 μg mL(-1)), and detection limits were within the range 0.12-0.43 ng mL(-1). The recoveries of the pyrethroids spiked in water samples at 10 ng mL(-1) ranged from 83 to 112%. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. A strategy to enhance the thermal stability of a nanostructured polypyrrole-based coating for solid phase microextraction

    International Nuclear Information System (INIS)

    Mehdinia, A.; Bashour, F.; Roohi, F.; Jabbari, A.

    2012-01-01

    We report on a nanostructured self-doped polypyrrole (SPPy) film that was prepared by an electrochemical technique in an electrolyte containing fluorosulfonic acid as the sulfonation reagent. The film was applied as a new fiber material for solid-phase microextraction (SPME) of the pesticides lindane, heptachlor, aldrin, endosulfans I and II prior to their quantitation by GC with electron capture detection. The SPPy nanoparticles have a diameter of 0 C) and satisfactory extraction efficiency. The thermal stability of the SPPy fiber is superior to common polypyrrole fibers. Extraction was optimized by means of the Taguchi orthogonal array experimental design with an OA 16 (4 5 ) matrix including extraction temperature, extraction time, salt concentration, stirring rate, and headspace volume. The method displays good repeatability (RSD -1 ; with an R 2 of >0. 998. The detection limits are -1 . The method was successfully applied to the analysis of the pesticides in skimmed milk and fruit juice samples, and recoveries are from 84 ± 1 to 105 ± 1%. (author)

  6. [Determination of five synthetic musks in perfume by headspace solid-phase microextraction and gas chromatography-mass spectrometry].

    Science.gov (United States)

    Wang, Guannan; Tang, Hua; Chen, Dazhou; Feng, Jie; Li, Lei

    2012-02-01

    A method for headspace solid-phase microextraction (HS-SPME), followed by gas chromatography-mass spectrometry (GC-MS) analysis was established for the determination of five commonly used synthetic musks in perfume. Two polycyclic musks (celestolide and tonalide) and three nitro musks (musk ambrette, musk xylene and musk ketone) were used as analytes in the optimization of the analytical method. Six parameters, such as the extraction temperature, equilibrium time, extraction time, desorption time, injector temperature and solution of salting out, were optimized by exposing the 65 microm polydimethylsiloxane-divinyl-benzene (PDMS-DVB) fiber to the headspace of magnetically stirred (600 r/min) sample. According to the results of the optimization experiments, the following conclusion can be drawn: The water-diluted sample in a 10 mL headspace-vial was efficiently extracted for 20 min after the system was equilibrated for 3 min at 60 degrees C. After extraction, the fiber was immediately inserted into the GC injector and desorbed at 250 degrees C for 3 min. The spiked recoveries were in the range of 82.0% - 103.3% and the relative standard deviations (RSDs) were between 1.8% and 9.4%. Meanwhile, the limits of detection (LODs) ranged from 0.6 ng/g to 2.1 ng/g. This method is characterized by rapidity, high sensitivity, good linearity and repeatability for all the target compounds. It is applicable to the analysis of synthetic musks in perfumes.

  7. Direct solid phase microextraction combined with gas chromatography - Mass spectrometry for the determination of biogenic amines in wine.

    Science.gov (United States)

    Papageorgiou, Myrsini; Lambropoulou, Dimitra; Morrison, Calum; Namieśnik, Jacek; Płotka-Wasylka, Justyna

    2018-06-01

    A direct method based on immersion solid phase microextraction (DI-SPME) gas chromatography mass-spectrometry (GC-MS) was optimized and validated for the determination of 16 biogenic amines in Polish wines. In the analysis two internal standards were used: 1,7-diaminoheptane and bis-3-aminopropylamine. The method allows for simultaneous extraction and derivatization, providing a simple and fast mode of extraction and enrichment. Different parameters which affect the extraction procedure were studied and optimized including ionic strength (0-25%), fiber materials (PDMS/DVB, PDMS/DVD + OC, Polyacrylate, Carboxen/PDMS and DVB/CAR/PDMS) and timings of the extraction, derivatization and desorption processes. Validation studies confirmed the linearity, sensitivity, precision and accuracy of the method. The method was successfully applied to the analysis of 44 wine samples originating from several regions of Poland and 3 wine samples from other countries. Analysis showed that many of the samples contained all examined biogenic amines. The method, assessed using an Eco-Scale tool with satisfactory results, was found to be green in terms of hazardous chemicals and solvents usage, energy consumption and production of waste. Therefore the proposed method can be safely used in the wine industry for routine analysis of BAs in wine samples with a minimal detrimental impact on human health and the environment. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. DETERMINATION AND CLASSIFICATION OF VOLATILE COMPOUNDS OF PASTIRMA USING SOLID PHASE MICROEXTRACTION/GAS CHROMATOGRAPHY/MASS SPECTROMETRY

    Directory of Open Access Journals (Sweden)

    Eda Demirok

    2013-10-01

    Full Text Available Pastırma, a traditional dry cured Turkish meat product, has a great number of specific aroma compounds, which occur as a result of lipid oxidation, protein degradation and formulation of çemen paste. These compounds give characteristic flavor to pastırma and the main objective of this study was to determine the nature of these compounds. Fifty-eight volatile compounds, grouped into nine chemical classes were identified using solid phase microextraction technique (SPME coupled to gas chromatography/mass spectrometry (GC-MS. Aldehydes, mostly lipid oxidation products, were determined as the major chemical group, representing 17.54-78.02% of total volatile compounds. The major volatile aldehyde was hexanal (2.36-55.41%, followed by 2-methyl-2-butenal (0.97-14.69% and then heptanal (0.29-4.77%. Sulfur compounds possibly derived from spices or formed by proteolysis of sulfur-containing amino acids, were the second most abundant group, with concentrations ranging between 6.04 and 50.60%. Other important volatile compounds of pastırma were aliphatic hydrocarbons, aromatic ketones, hydrocarbons, esters, alcohols, acids, terpenes, and furans.

  9. Solid-phase microextraction and gas chromatography-mass spectrometry of volatile compounds from avocado puree after microwave processing.

    Science.gov (United States)

    López, Mercedes G; Guzmán, G R; Dorantes, A L

    2004-05-14

    Microwave processing offers an alternative to blanch fruits and vegetables, since the application of high temperature and short time often results in minimum damage. An experimental design was used to investigate the effect of microwave time, pH, and avocado leaves (independent variables) on avocado flavor (response) using solid-phase microextraction (SPME)-GC-MS. Among the fully characterized flavor volatiles, 19 compounds were derived from lipid oxidation and only 4 from the avocado leaves. The main components derived from lipids were aldehydes, ketones and alcohols. Terpenoids, estragole, and 2-hexenal [E] were volatiles derived from avocado leaves. When leaves were added to fresh and microwaved avocado terpenoids and 2-hexenal [E]/hexanal ratio increased, this behavior was considered to have a positive effect on the sensorial quality of the product. From the statistical analysis of the experimental design, it was possible to determinate that the most important factors influencing the abundance of flavor compounds derived from lipids were microwave time and pH. Maximum values of these compounds were detected at high levels of microwave time and low values of pH. On the other hand, response surface of terpenoids and estragole showed an increment when microwave time and avocado leaf was increased. The region of optimum response was 30 s microwave time, pH 5.5, and 1% of avocado leaf.

  10. Phase field modeling of flexoelectricity in solid dielectrics

    Science.gov (United States)

    Chen, H. T.; Zhang, S. D.; Soh, A. K.; Yin, W. Y.

    2015-07-01

    A phase field model is developed to study the flexoelectricity in nanoscale solid dielectrics, which exhibit both structural and elastic inhomogeneity. The model is established for an elastic homogeneous system by taking into consideration all the important non-local interactions, such as electrostatic, elastic, polarization gradient, as well as flexoelectric terms. The model is then extended to simulate a two-phase system with strong elastic inhomogeneity. Both the microscopic domain structures and the macroscopic effective piezoelectricity are thoroughly studied using the proposed model. The results obtained show that the largest flexoelectric induced polarization exists at the interface between the matrix and the inclusion. The effective piezoelectricity is greatly influenced by the inclusion size, volume fraction, elastic stiffness, and the applied stress. The established model in the present study can provide a fundamental framework for computational study of flexoelectricity in nanoscale solid dielectrics, since various boundary conditions can be easily incorporated into the phase field model.

  11. Determination of volatile organic compounds in water by headspace solid-phase microextraction gas chromatography coupled to tandem mass spectrometry with triple quadrupole analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Cervera, M.I. [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain); Beltran, J., E-mail: joaquim.beltran@uji.es [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain); Lopez, F.J.; Hernandez, F. [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain)

    2011-10-17

    Highlights: {yields} Employing a statistical optimization improves results reducing experiments. {yields} Use of MS (QqQ) allows high sensitivity determination and improves identification capabilities. {yields} Using Q/q intensity ratios is a powerful tool to ensure compound identification. {yields} HS SPME GC-MS/MS method allows determination of VOCs in complex matrix water samples. - Abstract: In the present work, a rapid method with little sample handling has been developed for determination of 23 selected volatile organic compounds in environmental and wastewater samples. The method is based on headspace solid-phase microextraction (SPME) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) determination using triple quadrupole analyzer (QqQ) in electron ionization mode. The best conditions for extraction were optimised with a factorial design taking into account the interaction between different parameters and not only individual effects of variables. In the optimized procedure, 4 mL of water sample were extracted using a 10 mL vial and adding 0.4 g NaCl (final NaCl content of 10%). An SPME extraction with carboxen/polydimethylsiloxane 75 {mu}m fiber for 30 min at 50 deg. C (with 5 min of previous equilibration time) with magnetic stirring was applied. Chromatographic determination was carried out by GC-MS/MS working in Selected Reaction Monitoring (SRM) mode. For most analytes, two MS/MS transitions were acquired, although for a few compounds it was difficult to obtain characteristic abundant fragments. In those cases, a pseudo selected reaction monitoring (pseudo-SRM) with three ions was used instead. The intensity ratio between quantitation (Q) and confirmation (q) signals was used as a confirmatory parameter. The method was validated by means of recovery experiments (n = 6) spiking mineral water samples at three concentration levels (0.1, 5 and 50 {mu}g L{sup -1}). Recoveries between 70% and 120% were generally obtained with

  12. Distribution of Dechlorinating Bacteria between the Aqueous and Solid Phases

    Science.gov (United States)

    Cápiro, N. L.; Hatt, J. K.; Wang, Y.; Loeffler, F. E.; Pennell, K. D.

    2010-12-01

    Microbial monitoring of aquifers relies on nucleic acid biomarker analysis, which is typically performed with biomass recovered from groundwater samples; however, it is unclear what fraction of the target population(s) is associated with groundwater (i.e., planktonic cells) or is attached to solid phases (i.e., biofilms). Understanding how the titer of target organism(s) in groundwater correlates with the true cell titers of the target organism in the aquifer (i.e., planktonic plus attached cells) is critical for a meaningful interpretation of the data, the prediction of bioremediation performance, and the implementation of site management strategies. To evaluate the distribution of active cells between resident solid phase and the aqueous phase, one-dimensional columns were packed under water-saturated conditions with Bio-Dechlor INOCULUM, a PCE-to ethene-dechlorinating bacterial consortium containing both multiple Dehalococcoides (Dhc) strains and Geobacter lovleyi strain SZ (GeoSZ). The columns were packed with two distinct solid matrices: a low organic content sandy Federal Fine Ottawa soil or Appling soil with higher organic matter content. Influent reduced mineral salts medium supplied at a groundwater pore-water velocity of 0.3 m/day contained both 10 mM lactate as electron donor and 0.33 mM PCE as electron acceptor. Routine collection of biomass from column side ports and effluent samples measured the titers of target cells in the aqueous phase and determined when steady state conditions had been reached. A second set of column experiments evaluated delivery and filtration effects by the solid matrix (i.e., Federal Fine Ottawa sand versus Appling soil) under the same conditions except that electron donor or acceptor were omitted (no growth conditions). Quantitative real-time PCR (qPCR) analysis using Dhc and GeoSZ 16S rRNA gene-targeted primer and probe sets determined the planktonic cell counts, and destructive sampling of the columns allowed measurement

  13. Solid phase microextraction (SPME) used for direct fruit- body sampling in comparison with ase-gc-ms to describe pah partitioning in mushroom cultures

    Czech Academy of Sciences Publication Activity Database

    Moder, M.; Cajthaml, Tomáš; Schrader, S.; Šašek, Václav

    2002-01-01

    Roč. 11, č. 6 (2002), s. 284-288 ISSN 1018-4619 R&D Projects: GA MŠk LN00B030 Institutional research plan: CEZ:AV0Z5020903 Keywords : pah * transiocation * mushrooms Subject RIV: EE - Microbiology, Virology Impact factor: 0.309, year: 2002

  14. Characterization of Human Skin Emanations by Solid Phase Microextraction (SPME) Extraction of Volatiles and Subsequent Analysis by Gas Chromatography-Mass Spectrometry (GC-MS)

    Science.gov (United States)

    2005-05-06

    acid γ-C8- lactone (Z)-3-methyl-2- hexenoic acid 2-methyl-2-butenoic 4-ethylpentanoic Heptanoic acid 74 acid acid 3-methyl-2- pentenoic acid (Z...octenoic acid heptanoic acid 2-methylheptanoic acid Nonanoic acid octanoic acid (E)-3-methyl-2-hexenoic acid C9- unsaturated acid nonanoic acid...phenol Decanoic acid decanoic acid γ-C9- lactone Undecanoic acid undecanoic acid n-octanoic acid dodecanoic acid 2-methyloctanoic acid

  15. Studies in Solid Phase Peptide Synthesis: A Personal Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, A R

    2007-06-01

    By the early 1970s it had became apparent that the solid phase synthesis of ribonuclease A could not be generalized. Consequently, virtually every aspect of solid phase peptide synthesis (SPPS) was reexamined and improved during the decade of the 1970s. The sensitive detection and elimination of possible side reactions (amino acid insertion, N{sup {alpha}}-trifluoroacetylation, N{sup {alpha}{var_epsilon}}-alkylation) was examined. The quantitation of coupling efficiency in SPPS as a function of chain length was studied. A new and improved support for SPPS, the 'PAM-resin', was prepared and evaluated. These and many other studies from the Merrifield laboratory and elsewhere increased the general acceptance of SPPS leading to the 1984 Nobel Prize in Chemistry for Bruce Merrifield.

  16. Semi-automated microwave assisted solid-phase peptide synthesis

    DEFF Research Database (Denmark)

    Pedersen, Søren Ljungberg

    measurements during microwave heating. Then we developed protocols for on-resin reductive amination for anchoring of the first amino acids to a BAL handle. Finally, we used the new instrument and the optimized protocols to assist in the synthesis of a range of difficult and long sequences. We believe...... to coupling reagents, resins, solvents etc. We have previously reported on microwave heating to promote a range of solid-phase reactions in SPPS. Here we present a new, flexible semi-automated instrument for the application of precise microwave heating in solid-phase synthesis. It combines a slightly modified...... Biotage Initiator microwave instrument, which is available in many laboratories, with a modified semi-automated peptide synthesizer from MultiSynTech. A custom-made reaction vessel is placed permanently in the microwave oven, thus the reactor does not have to be moved between steps. Mixing is achieved...

  17. Semi-automated microwave assisted solid-phase peptide synthesis

    DEFF Research Database (Denmark)

    Pedersen, Søren Ljungberg

    with microwaves for SPPS has gained in popularity as it for many syntheses has provided significant improvement in terms of speed, purity, and yields, maybe especially in the synthesis of long and "difficult" peptides. Thus, precise microwave heating has emerged as one new parameter for SPPS, in addition...... to coupling reagents, resins, solvents etc. We have previously reported on microwave heating to promote a range of solid-phase reactions in SPPS. Here we present a new, flexible semi-automated instrument for the application of precise microwave heating in solid-phase synthesis. It combines a slightly modified...... Biotage Initiator microwave instrument, which is available in many laboratories, with a modified semi-automated peptide synthesizer from MultiSynTech. A custom-made reaction vessel is placed permanently in the microwave oven, thus the reactor does not have to be moved between steps. Mixing is achieved...

  18. Addition of amines to naphthoquinone in water and solid phase

    International Nuclear Information System (INIS)

    Martinez, Sabrina T.; Silva, Barbara V.; Pinto, Angelo C.; Ferreira, Vitor F.; Silva, Fernando de Carvalho da

    2012-01-01

    Considering all the aspects of the principles of green chemistry, we present herein the addition reactions of amines to 1,4-naphthoquinone in water as solvent and also in solid phase. These reactions resulted in very colorful products that were easily monitored by thin layer chromatography and consequently easy to separate. Therefore, they are interesting experiments for experimental organic chemistry in the classrooms or in the laboratories. (author)

  19. Binding of properdin to solid-phase immune complexes

    DEFF Research Database (Denmark)

    Junker, A; Baatrup, G; Svehag, S E

    1998-01-01

    The capacity of serum to support deposition of C3, properdin and factor B was studied by enzyme-linked immunosorbent assay using solid-phase immune complexes (IC) for activation of complement. Deposition of C3 and properdin occurred in fairly dilute normal human serum (NHS), but factor B uptake...... fixed to IC was the principal ligand for properdin in the assay. The findings could have biological implications relating to complement-mediated modification of immune complexes in disease....

  20. A solid-phase radioimmunoassay for detection of tetanus antibodies

    International Nuclear Information System (INIS)

    Dow, B.C.; Barr, A.; Crawford, R.J.; Mitchell, R.

    1983-01-01

    A solid-phase radioimmunoassay has been developed as a screening technique for tetanus antibodies in blood plasma. It is based on the principle of a commercial test for Hepatitis B antibody. Compared to previous screening techniques, the radioimmunoassay showed better stability with no apparent loss of sensitivity over a 2 month period. This technique has proved useful in determining tetanus immunity and in monitoring free antibody level in treated cases of clinical tetanus. (U.K.)

  1. Determinação de pesticidas organofosforados em água usando microextração em fase sólida e CGAR-EM Determination of organophosphorus pesticides in water using SPME-GC-MS

    Directory of Open Access Journals (Sweden)

    Fernando Carvalho Silva

    1999-04-01

    Full Text Available Solid-phase microextraction (SPME has been applied to direct extraction of 11 organophosphorus pesticides in water using a 100 mm fiber polydimethylsiloxane. The method was evaluated with respect time of exposure, detection limits (LODs, linearity and precision. The detection limits (S/N = 3 depend of each pesticide and varie about ng/L levels. The linearity was satisfactory with coefficients of correlation usually greater than 0.993. The precision of the method was determined by extraction from 4.0 mg/L aqueous standard with coefficients of variation between 5.7 to 17.2%.

  2. Analysis of Five Earthy-Musty Odorants in Environmental Water by HS-SPME/GC-MS

    Directory of Open Access Journals (Sweden)

    Zhen Ding

    2014-01-01

    Full Text Available The pressing issue of earthy and musty odor compounds in natural waters, which can affect the organoleptic properties of drinking water, makes it a public health concern. A simple and sensitive method for simultaneous analysis of five odorants in environmental water was developed by headspace solid-phase microextraction (HS-SPME coupled to chromatography-mass spectrometry (GC-MS, including geosmin (GSM and 2-methylisoborneol (2-MIB, as well as dimethyl trisulfide (DMTS, β-cyclocitral, and β-ionone. Based on the simple modification of original magnetic stirrer purchased from CORNING (USA, the five target compounds can be separated within 23 min, and the calibration curves show good linearity with a correlation coefficient above 0.999 (levels = 5. The limits of detection (LOD are all below 1.3 ng L−1, and the relative standard deviation (%RSD is between 4.4% and 9.9% (n = 7 and recoveries of the analytes from water samples are between 86.2% and 112.3%. In addition, the storage time experiment indicated that the concentrations did not change significantly for GSM and 2-MIB if they were stored in canonical environment. In conclusion, the method in this study could be applied for monitoring these five odorants in natural waters.

  3. Study of flavour compounds from orange juices by HS-SPME and GC-MS

    Science.gov (United States)

    Schmutzer, G.; Avram, V.; Covaciu, F.; Feher, I.; Magdas, A.; David, L.; Moldovan, Z.

    2013-11-01

    The flavour of the orange juices, which gives the taste and odour of the product, is an important criterion about the products quality for consumers. A fresh single strength and two commercial orange juices (obtained from concentrate) flavour profile were studied using a selective and sensitive gas chromatography - mass spectrometry (GC-MS) analytical system, after a solvent free, single step preconcentration and extraction technique, the headspace solid phase microextraction (HP-SPME). In the studied orange juices 55 flavour compounds were detected and classified as belonging to the esters, alcohols, ketones, monoterpenes and sesquiterpenes chemical families. The fresh single strength orange juice was characterized by high amount of esters, monoterpenes and sesquiterpenes. Limonene and valencene were the most abundant flavours in this fresh natural orange juice. Alcohols and ketones were found in higher concentration in the commercial orange juices made from concentrate, than in the single strength products. Nevertheless, in commercial juices the most abundant flavour was limonene and α-terpineol. The results highlight clear differences between fresh singles strength orange juice and juice from concentrate. The orange juices reconstructed from concentrate, made in Romania, present low quantity of flavour compounds, suggesting the absence or a low rearomatization process, but extraneous components were not detected.

  4. Volatile emerging contaminants in melon fruits, analysed by HS-SPME-GC-MS.

    Science.gov (United States)

    Cincotta, Fabrizio; Verzera, Antonella; Tripodi, Gianluca; Condurso, Concetta

    2018-03-01

    The aim of this research was to develop and validate a headspace-solid phase micro-extraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS) method for the determination of volatile emerging contaminants in fruit. The method showed good precision (RSD ≤ 14%) and satisfactory recoveries (99.1-101.7%) and LOD and LOQ values ranging between 0.011-0.033 μg kg -1 and 0.037-0.098 μg kg -1 , respectively. The method was applied to investigate the content of volatile emerging contaminants in two varieties of melon fruit (Cucumis melo L.) cultivated adjoining high-risk areas. Glycol ethers, BHT, BHA and BTEX (benzene, toluene, ethylbenzene and xylene) were determined in melon fruit pulps for the first time, with different sensitivities depending on sample and variety. Although the amount of the volatile contaminants in the melon samples were in the order of µg kg -1 , the safety of vegetable crops cultivated near risk areas should be more widely considered. The results showed that this accurate and reproducible method can be useful for routine safety control of fruits and vegetables.

  5. Fingerprint of volatiles from plant extracts based on SPME-GC-MS

    Directory of Open Access Journals (Sweden)

    Ezequias P. Siqueira

    Full Text Available The Laboratory of Chemistry of Natural Products has an ex situ collection of extracts from organisms of the biodiversity aiming at bioprospecting. Nowadays the collection has about 4000 extracts from 1000 different species. Extracts are used to identify new bioactive compounds that could be useful for developing new drugs against neglected diseases like leishmaniosis, Chagas disease, malaria and tuberculosis. After biologic assays, the bioactive extracts need to be prepared in larger quantity to allow isolation and characterization of the bioactive component. At this time, it is important to not only confirm the bioactivity of new extract but also check if its composition is similar to the old one. It was evaluated the ability of Solid Phase Microextraction and Gas Chromatography-Mass Spectrometry analysis (SPME-GC-MS. It was used the AMDIS (Automatic Mass Spectral Deconvolution and Identification System software as tools to collect and to compare the chromatographic profiles of each extract (fingerprint. Forty six samples were analyzed, it was possible to infer from the composition of each sample and common compounds. Nine groups of samples, collected at different time, were analyzed and seasonal modifications between then could be elucidated. The results showed that this methodology can be used to monitor the composition of extracts, allowing to monitor chemical changes that may occur during storage periods and to investigate the occurrence of a determined component in different extracts.

  6. ANALYTICAL APPROACH OF THE VOLATILE FRACTION OF Solanum quitoense BY HS-SPME/GC-MS

    Directory of Open Access Journals (Sweden)

    EDUARDO CORPAS IGUARÁN

    2017-07-01

    Full Text Available The species of lulo fruit (Solanum quitoense, predominant in Colombia, is a promising fruit for both national and international market due to its flavor and nutritional characteristics, which generated the interest to know the volatile composition of its pulp. After adjusting, the chromatographic conditions necessary to analyze volatile fraction of this fruit, the effect of the temperature and time of adsorption was measured through the headspace - solid phase microextraction (HS-SPME and gas chromatography - mass spectrometry (GC-MS, on the area of volatile compounds of S. quitoense, by applying the experimental design of a factor. The descriptive analysis suggested that the adsorption at 60°C and 30 minutes promoted optimal recovery of volatiles as well as internal standard (1-Octanol, with recovery of 99,66% at 60ºC, while the non-parametric test Kruskal-Wallis showed statistical differences in the effect of time (P= 0,018, but not of the temperature adsorption (P= 0,058 upon the volatiles compounds area. A predominance of esters (48,98%, aldehydes (18,37%, and alcohols (14,29% was observed and also were found compounds of greatest area such as 3-hexen-1-ol acetate, acetic acid methyl ester, and acetic acid hexyl ester. These metabolites determine the characteristic aroma from lulo pulp and influence the consumer preference.

  7. Characterization of the Key Aroma Compounds in Proso Millet Wine Using Headspace Solid-Phase Microextraction and Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jingke Liu

    2018-02-01

    Full Text Available The volatile compounds in proso millet wine were extracted by headspace solid-phase microextraction (85 μm polyacrylate (PA, 100 μm polydimethylsiloxane (PDMS, 75 μm Carboxen (CAR/PDMS, and 50/30 μm divinylbenzene (DVB/CAR/PDMS fibers, and analyzed using gas chromatography-mass spectrometry; the odor characteristics and intensities were analyzed by the odor activity value (OAV. Different sample preparation factors were used to optimize this method: sample amount, extraction time, extraction temperature, and content of NaCl. A total of 64 volatile compounds were identified from the wine sample, including 14 esters, seven alcohols, five aldehydes, five ketones, 12 benzene derivatives, 12 hydrocarbons, two terpenes, three phenols, two acids, and two heterocycles. Ethyl benzeneacetate, phenylethyl alcohol, and benzaldehyde were the main volatile compounds found in the samples. According to their OAVs, 14 volatile compounds were determined to be odor-active compounds (OAV > 1, and benzaldehyde, benzeneacetaldehyde, 1-methyl-naphthalene, 2-methyl-naphthalene, and biphenyl were the prominent odor-active compounds (OAV > 50, having a high OAV. Principal component analysis (PCA showed the difference of distribution of the 64 volatile compounds and 14 odor-active compounds with four solid-phase microextraction (SPME fibers.

  8. Solid phase radioimmunoassays for human C-reactive protein

    International Nuclear Information System (INIS)

    Shine, B.; Beer, F.C. de; Pepys, M.B.

    1981-01-01

    Two new, rapid and sensitive radioimmunoassays for human C-reactive protein (CRP) have been established using antiserum coupled to magnetizable cellulose particles, which facilitate phase separation. A single antibody method, using solid phase anti-CRP, provides a sensitivity of 50 μg/l with a 1-h incubation time and intra- and inter-assay coefficients of variation of 10%. A double antibody method, using fluid phase rabbit anti-CRP serum and solid phase sheep anti-rabbit IgG serum, provides a sensitivity of 3 μg/l with an overnight incubation and intra- and inter-assay coefficients of variation of 10%. Among 468 sera from normal adult volunteer blood donors the median CRP concentration was 800 μg/l, interquartile range 340-1700 μg/l and range 70-29,000 μg/l. Ninety percent of samples contained less than 3 mg/l and 99% less than 10 mg/l. Low levels (14-650 μg/l) of CRP were detected both in amniotic fluids and in cerebrospinal fluids. (Auth.)

  9. Solid phase microextraction as a reliable alternative to conventional extraction techniques to evaluate the pattern of hydrolytically released components in Vitis vinifera L. grapes.

    Science.gov (United States)

    Perestrelo, Rosa; Caldeira, Michael; Câmara, José S

    2012-06-15

    In present research, headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-qMS), was evaluated as a reliable and improved alternative to the commonly used liquid-liquid extraction (LLE) technique for the establishment of the pattern of hydrolytically released components of 7 Vitis vinifera L. grape varieties, commonly used to produce the world-famous Madeira wine. Since there is no data available on their glycosidic fractions, at a first step, two hydrolyse procedures, acid and enzymatic, were carried out using Boal grapes as matrix. Several parameters susceptible of influencing the hydrolytic process were studied. The best results, expressed as GC peak area, number of identified components and reproducibility, were obtained using ProZym M with b-glucosidase activity at 35°C for 42h. For the extraction of hydrolytically released components, HS-SPME technique was evaluated as a reliable and improved alternative to the conventional extraction technique, LLE (ethyl acetate). HS-SPME using DVB/CAR/PDMS as coating fiber displayed an extraction capacity two fold higher than LLE (ethyl acetate). The hydrolyzed fraction was mainly characterized by the occurrence of aliphatic and aromatic alcohols, followed by acids, esters, carbonyl compounds, terpenoids, and volatile phenols. Concerning to terpenoids its contribution to the total hydrolyzed fraction is highest for Malvasia Cândida (23%) and Malvasia Roxa (13%), and their presence according previous studies, even at low concentration, is important from a sensorial point of view (can impart floral notes to the wines), due to their low odor threshold (μg/L). According to the obtained data by principal component analysis (PCA), the sensorial properties of Madeira wines produced by Malvasia Cândida and Malvasia Roxa could be improved by hydrolysis procedure, since their hydrolyzed fraction is mainly characterized by terpenoids (e.g. linalool, geraniol) which are responsible

  10. Full automation of solid-phase microextraction/on-fiber derivatization for simultaneous determination of endocrine-disrupting chemicals and steroid hormones by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Yang, Lihua; Lan, Chongyu; Liu, Hongtao; Dong, Jun; Luan, Tiangang

    2006-09-01

    A fully automated method using direct immersion solid-phase microextraction (DI-SPME) and headspace on-fiber silylation for simultaneous determinations of exogenous endocrine-disrupting chemicals (EDCs) and endogenous steroid hormones in environmental aqueous and biological samples by gas chromatography-mass spectrometry (GC-MS) was developed and compared to a previously reported manual method. Three EDCs and five endocrine steroid hormones were selected to evaluate this method. The extraction and derivatization time, ion strength, pH, incubation temperature, sample volume, and extraction solvent were optimized. Satisfactory results in pure water were obtained in terms of linearity of calibration curve (R2=0.9932-1.0000), dynamic range (3 orders of magnitude), precision (4-9% RSD), as well as LOD (0.001-0.124 microg L(-1)) and LOQ (0.004-0.413 microg L(-1)), respectively. These results were similar to those obtained using a manual method, and moreover, the precision was improved. This new automated method has been applied to the determinations of target compounds in real samples used in our previous study on a manual SPME method. Exogenous octylphenol (OP), technical grade nonylphenol (t-NP), and diethylstilbestrol (DES) were at 0.13, 5.03, and 0.02 microg L(-1) in river water and 3.76, 13.25, and 0.10 microg L(-1) in fish serum, respectively. Natural steroid hormones estrone (E1), 17beta-estradiol (E2), and testosterone (T) were at 0.19, 0.11, and 6.22 microg L(-1) in river water; and in female fish serum E1, E2, and pregnenolone (PREG) were at 1.37, 1.95, and 6.25 microg L(-1), respectively. These results were confirmed by the manual method. The developed fully automated SPME and on-fiber silylation procedures showed satisfactory applications in environmental analysis and the performances show improved precision and a reduced analysis time compared to the manual method.

  11. Validation of an analytical method for analysis of cannabinoids in hair by headspace solid-phase microextraction and gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Emídio, Elissandro Soares; Prata, Vanessa de Menezes; Dórea, Haroldo Silveira

    2010-06-18

    The development of an analytical method for the determination of Delta(9)-tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in samples of human hair is described. Samples were subjected to a procedure based on the combination of headspace solid-phase microextraction (HS-SPME) with gas chromatography linked with mass spectrometry operating in tandem mode (GC-MS/MS). A 10 mg aliquot of sample was firstly decontaminated using petroleum ether, deionized water and dichloromethane (2 mL of each solvent), for 10 min under sonication, and then digested in alkaline solution (1 mol L(-1) NaOH). The method variables evaluated were pH, mass of hair, fiber type, extraction temperature, desorption time, ionic strength, pre-equilibrium time and extraction time. Parameters concerning operation of the tandem mode MS/MS were also assessed and optimized. Validation of the method demonstrated excellent linearity in the range 0.1-8.0 ng mg(-1), with regression coefficients better than 0.994. Precision was determined using two different concentrations (upper and lower limits of the linear range), and RSD values were between 6.6 and 16.4%. Absolute recoveries (measured in triplicate) were in the range 1.1-8.7%, and limits of detection and quantification were 0.007-0.031 ng mg(-1) and 0.012-0.062 ng mg(-1), respectively. The LOQ for THC (0.062 ng mg(-1)) was below the cut-off value (LOQ Toxicologie Analytique (SFTA). The optimized SPME method was applied in analysis of hair samples from Cannabis drug users, showing that CBN and CBD were present in all samples analyzed. 2010 Elsevier B.V. All rights reserved.

  12. Analysis of carbamate and phenylurea pesticide residues in fruit juices by solid-phase microextraction and liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Sagratini, Gianni; Mañes, Jordi; Giardiná, Dario; Damiani, Pietro; Picó, Yolanda

    2007-04-20

    A new analysis method to detect carbamates and phenylurea pesticide residues in fruit juices was developed using solid-phase microextraction (SPME) coupled with liquid chromatography-single quadrupole mass spectrometry (LC/MS) and liquid chromatography-quadrupole ion trap mass spectrometry (LC/QIT-MS). The pesticide residues present in watery matrices as fruit juices were extracted using three types of fibers: 50-microm Carbowax/templated resin (CW/TPR), 60-mum poly(dimethylsiloxane)/divinylbenzene (PDMS/DVB) and 85-microm polyacrylate. The different extraction conditions were evaluated choosing as the best parameters 90 min (time), 20 degrees C (temperature) and 1 ml (volume). After extraction, the desorption (in a static mode) was performed in the specific interface chamber SPME/HPLC, previously filled with 70% methanol and 30% water. The best recoveries, evaluated at two fortification levels (0.2 and 0.5 mg kg(-1)) in fruit juices, were obtained using PDMS/DVB and CW/TPR fibers, and ranged from 25 to 82% (monolinuron, diuron and diethofencarb), with relative standard deviations (RSDs) from 1 to 17%. All the limits of quantification (LOQs) were in the range of 0.005-0.05 microg ml(-1) and, in any case, equal to, or lower than, maximum residue limits (MRLs) established by Italian and Spanish legislations. The mass spectrometry analyses were carried out using an electrospray ionization (ESI) source operating in the positive mode both for single quadrupole and for QIT mass analysers, operating in selected ion monitoring (SIM) and in multiple reaction monitoring (MRM) modes, respectively. The proposed new method can be applied to the determination of selected pesticides in real samples of fruit juices.

  13. A powerful methodological approach combining headspace solid phase microextraction, mass spectrometry and multivariate analysis for profiling the volatile metabolomic pattern of beer starting raw materials.

    Science.gov (United States)

    Gonçalves, João L; Figueira, José A; Rodrigues, Fátima P; Ornelas, Laura P; Branco, Ricardo N; Silva, Catarina L; Câmara, José S

    2014-10-01

    The volatile metabolomic patterns from different raw materials commonly used in beer production, namely barley, corn and hop-derived products - such as hop pellets, hop essential oil from Saaz variety and tetra-hydro isomerized hop extract (tetra hop), were established using a suitable analytical procedure based on dynamic headspace solid-phase microextraction (HS-SPME) followed by thermal desorption gas chromatography-quadrupole mass spectrometry detection (GC-qMS). Some SPME extraction parameters were optimized. The best results, in terms of maximum signal recorded and number of isolated metabolites, were obtained with a 50/30 μm DVB/CAR/PDMS coating fiber at 40 °C for 30 min. A set of 152 volatile metabolites comprising ketones (27), sesquiterpenes (26), monoterpenes (19), aliphatic esters (19), higher alcohols (15), aldehydes (11), furan compounds (11), aliphatic fatty acids (9), aliphatic hydrocarbons (8), sulphur compounds (5) and nitrogen compounds (2) were positively identified. Each raw material showed a specific volatile metabolomic profile. Monoterpenes in hop essential oil and corn, sesquiterpenes in hop pellets, ketones in tetra hop and aldehydes and sulphur compounds in barley were the predominant chemical families in the targeted beer raw materials. β-Myrcene was the most dominant volatile metabolite in hop essential oil, hop pellets and corn samples while, in barley, the predominant volatile metabolites were dimethyl sulphide and 3-methylbutanal and, in tetra hop, 6-methyl-2-pentanone and 4-methyl-2-pentanone. Principal component analysis (PCA) showed natural sample grouping among beer raw materials. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Evaluation of volatile metabolites as markers in Lycopersicon esculentum L. cultivars discrimination by multivariate analysis of headspace solid phase microextraction and mass spectrometry data.

    Science.gov (United States)

    Figueira, José; Câmara, Hugo; Pereira, Jorge; Câmara, José S

    2014-02-15

    To gain insights on the effects of cultivar on the volatile metabolomic expression of different tomato (Lycopersicon esculentum L.) cultivars--Plum, Campari, Grape, Cherry and Regional, cultivated under similar edafoclimatic conditions, and to identify the most discriminate volatile marker metabolites related to the cultivar, the chromatographic profiles resulting from headspace solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-qMS) analysis, combined with multivariate analysis were investigated. The data set composed by the 77 volatile metabolites identified in the target tomato cultivars, 5 of which (2,2,6-trimethylcyclohexanone, 2-methyl-6-methyleneoctan-2-ol, 4-octadecyl-morpholine, (Z)-methyl-3-hexenoate and 3-octanone) are reported for the first time in tomato volatile metabolomic composition, was evaluated by chemometrics. Firstly, principal component analysis was carried out in order to visualise data trends and clusters, and then, linear discriminant analysis in order to detect the set of volatile metabolites able to differentiate groups according to tomato cultivars. The results obtained revealed a perfect discrimination between the different Lycopersicon esculentum L. cultivars considered. The assignment success rate was 100% in classification and 80% in prediction ability by using "leave-one-out" cross-validation procedure. The volatile profile was able to differentiate all five cultivars and revealed complex interactions between them including the participation in the same biosynthetic pathway. The volatile metabolomic platform for tomato samples obtained by HS-SPME/GC-qMS here described, and the interrelationship detected among the volatile metabolites can be used as a roadmap for biotechnological applications, namely to improve tomato aroma and their acceptance in the final consumer, and for traceability studies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Simple determination of hydrazine in waste water by headspace solid-phase micro extraction and gas chromatography-tandem mass spectrometry after derivatization with trifluoro pentanedione.

    Science.gov (United States)

    Oh, Jin-Aa; Shin, Ho-Sang

    2017-01-15

    A headspace solid-phase micro extraction (HS-SPME) and gas chromatography-tandem mass spectrometric (GC-MS/MS) method is described to detect hydrazine after derivatization with 1,1,1-trifluoro-2,4-pentanedione (1,1,1-TFPD) to 3-methyl-5-(trifluoromethyl) pyrazole in industrial waste water. The following optimal HS-SPME conditions were used: 85 μm-carboxen-polydimethylsiloxane fibre, 100 mg L -1 TFPD, saturated NaCl, an extraction/derivatization temperature of 80 °C, a heating time of 40 min, and a pH of 9.5. Under the established conditions, the detection and quantification limits were 0.002 μg L -1 and 0.007 μg L -1  by using 5 mL of waste water and the intra- and inter-day relative standard deviations were less than 10.2% at concentrations of 0.02 and 0.1 μg L -1 . The calibration curve showed good linearity, with r 2  = 0.998; the accuracy was in the range of 98.0-103%; and the precision of the assay was less than 10.2% in industrial waste water. Hydrazine was detected over a concentration range of 0.011-0.074 μg L -1 in 5 of 20 waste water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Determination of caffeine, myosmine, and nicotine in chocolate by headspace solid-phase microextraction coupled with gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Müller, Christoph; Vetter, Florian; Richter, Elmar; Bracher, Franz

    2014-02-01

    The occurrence of the bioactive components caffeine (xanthine alkaloid), myosmine and nicotine (pyridine alkaloids) in different edibles and plants is well known, but the content of myosmine and nicotine is still ambiguous in milk/dark chocolate. Therefore, a sensitive method for determination of these components was established, a simple separation of the dissolved analytes from the matrix, followed by headspace solid-phase microextraction coupled with gas chromatography-tandem mass spectrometry (HS-SPME-GC-MS/MS). This is the first approach for simultaneous determination of caffeine, myosmine, and nicotine with a convenient SPME technique. Calibration curves were linear for the xanthine alkaloid (250 to 3000 mg/kg) and the pyridine alkaloids (0.000125 to 0.003000 mg/kg). Residuals of the calibration curves were lower than 15%, hence the limits of detection were set as the lowest points of the calibration curves. The limits of detection calculated from linearity data were for caffeine 216 mg/kg, for myosmine 0.000110 mg/kg, and for nicotine 0.000120 mg/kg. Thirty samples of 5 chocolate brands with varying cocoa contents (30% to 99%) were analyzed in triplicate. Caffeine and nicotine were detected in all samples of chocolate, whereas myosmine was not present in any sample. The caffeine content ranged from 420 to 2780 mg/kg (relative standard deviation 0.1 to 11.5%) and nicotine from 0.000230 to 0.001590 mg/kg (RSD 2.0 to 22.1%). © 2014 Institute of Food Technologists®

  17. Quantification of 4-hydroxy-2,5-dimethyl-3-furanone in fruit samples using solid phase microextraction coupled with gas chromatography-mass spectrometry.

    Science.gov (United States)

    Chen, Yong; Sidisky, Leonard M

    2011-09-23

    Furaneol is an important aroma compound. It is very difficult to extract furaneol from food matrices and separate it on a gas chromatography column due to its high polarity and instability. A new quantitative method was developed to quantify furaneol in aqueous samples by the use of derivatization/solid phase microextraction (SPME) coupled with gas chromatography/mass spectrometry (GC/MS). The derivatization was carried out by reacting pentafluorobenzyl bromide with furaneol in basic solutions at elevated temperatures. The derivative was stable and less polar so that SPME-GC/MS could be applied for extraction, separation and detection. The automated analytical method had a limit of detection (LOD) of 0.5 ng mL(-1), a limit of quantification (LOQ) of 2 ng mL(-1), a repeatability of 9.5%, and a linear range from 2 to 500 ng mL(-1). The method was applied to analyze fruit samples. And it was found that the concentrations of furaneol in tomato ranged from 95 to 173 μg kg(-1), in strawberries ranged from 1663 to 4852 μg kg(-1). The results were verified with a LC procedure. To facilitate analytical method development, some physico-chemical parameters for furaneol were determined in this work. Its solubility in water was determined as 0.315 g mL(-1) (25°C). Its LogD in water and LogP in 0.1 M phosphate buffer were -0.133 and 0.95 (20 °C), respectively. Its pKa was 8.56 (20 °C). Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Volatile Hydrocarbon Analysis in Blood by Headspace Solid-Phase Microextraction: The Interpretation of VHC Patterns in Fire-Related Incidents.

    Science.gov (United States)

    Waters, Brian; Hara, Kenji; Ikematsu, Natsuki; Takayama, Mio; Kashiwagi, Masayuki; Matsusue, Aya; Kubo, Shin-Ichi

    2017-05-01

    A headspace solid-phase microextraction (HS-SPME) technique was used to quantitate the concentration of volatile hydrocarbons from the blood of cadavers by cryogenic gas chromatography-mass spectroscopy. A total of 24 compounds including aromatic and aliphatic volatile hydrocarbons were analyzed by this method. The analytes in the headspace of 0.1 g of blood mixed with 1.0 mL of distilled water plus 1 µL of an internal standard solution were adsorbed onto a 100-µm polydimethylsiloxane fiber at 0°C for 15 min, and measured using a GC-MS full scan method. The limit of quantitation for the analytes ranged from 6.8 to 10 ng per 1 g of blood. This method was applied to actual autopsy cases to quantitate the level of volatile hydrocarbons (VHCs) in the blood of cadavers who died in fire-related incidents. The patterns of the VHCs revealed the presence or absence of accelerants. Petroleum-based fuels such as gasoline and kerosene were differentiated. The detection of C8-C13 aliphatic hydrocarbons indicated the presence of kerosene; the detection of C3 alkylbenzenes in the absence of C8-C13 aliphatic hydrocarbons was indicative of gasoline; and elevated levels of styrene or benzene in the absence of C3/C4 alkylbenzenes and aliphatic hydrocarbons indicated a normal construction fire. This sensitive HS-SPME method could help aid the investigation of fire-related deaths by providing a simple pattern to use for the interpretation of VHCs in human blood. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Development of new portable miniaturize solid phase microextraction of silver-APDC complex using micropipette tip in-syringe system couple with electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Naeemullah; Kazi, Tasneem Gul; Afridi, Hassan Imran; Shah, Faheem; Arain, Sadaf Sadia; Arain, Salma Aslam; Panhwar, Abdul Haleem; Arain, Mariam Shahzadi; Samoon, Muhammad Kashif

    2016-02-05

    An innovative and simple miniaturized solid phase microextraction (M-SPME) method, was developed for preconcentration and determination of silver(I) in the fresh and waste water samples. For M-SPME, a micropipette tip packed with activated carbon cloth (ACC) as sorbent, in a syringe system. The size, morphology and elemental composition of ACC before and after adsorption of analyte have been characterized by scanning electron microscopy and energy dispersive spectroscopy. The sample solution treated with a complexing reagent, ammonium pyrrolidine dithiocarbamate (APDC), was drawn into the syringe filled with ACC and dispensed manually for 2 to 10 aspirating/dispensing cycle. Then the Ag- complex sorbed on the ACC in micropipette was quantitatively eluted by drawing and dispensing of different concentrations of acids for 2 to 5 aspirating/dispensing cycles. The extracted Ag ions with modifier were injected directly into the electrothermal atomic absorption spectrometry for analysis. The influence of different variables on the extraction efficiency, including the concentration of ligand, pH, sample volume, eluent type, concentration and volume was investigated. Validity and accuracy of the developed method was checked by the standard addition method. Reliability of the proposed methodology was checked by the relative standard deviation (%RSD), which was found to be <5%. Under the optimized experimental variables, the limits of detection (LOD) and enhancement factors (EF), were obtained to be 0.86 ng L(-1) and 120, respectively. The proposed method was successfully applied for the determination of trace levels of silver ions in fresh and waste water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Analysis of volatile compounds emitted from fresh Syringa oblata flowers in different florescence by headspace solid-phase microextraction-gas chromatography-mass spectrometry.

    Science.gov (United States)

    Li, Zu-Guang; Lee, Maw-Rong; Shen, De-Long

    2006-08-18

    In this study, a simple and solvent-free method was developed for determination of the volatile compounds from fresh flowers of Syringa oblata using headspace solid-phase microextraction and gas chromatography-mass spectrometry. The SPME parameters were studied, the optimum conditions of a 65mum polydimethylsiloxan/divinylbenezene (PDMS/DVB), extraction temperature of 25 degrees C and extraction time of 30 min were obtained and applied to extraction of the volatile compounds emitted from fresh flowers of S. oblata. The volatile compounds released from fresh flowers of S. oblata were separated and identified by GC-MS. Lilac aldehyde A, lilac aldehyde B, lilac aldehyde C, lilac aldehyde D, lilac alcohol A, lilac alcohol B, lilac alcohol C, lilac alcohol D, alpha-pinene, sabinene, beta-pinene, myrcene, d-limonene, eucalyptol, cis-ocimene, benzaldehyde, terpinolene, linalool, benzene acetaldehyde, alpha-terpineol, p-methoxyanisole, p-anisaldehyde, (Z,E)-alpha-farnesene and (E,E)-alpha-farnesene were the most abundant volatiles released from fresh flowers of S. oblata var. alba. The relative contents of main volatile fragrance were found to be different in emissions from two varieties of S. oblata flowers (white or purple in color). The four isomers of lilac alcohol and four isomer lilac aldehyde were the characteristic components of the scent of fresh flowers of S. oblata. The main volatile fragrance from fresh flowers of S. oblata var. alba in different florescence ((A) flower buds; (B) at the early stage of flower blooming; (C) during the flower blooming; (D) at the end of flower blooming; (E) senescence) were studied in this paper. The results demonstrated that headspace SPME-GC-MS is a simple, rapid and solvent-free method suitable for analysis of volatile compounds emitted from fresh flowers of S. oblata in different florescence.

  1. Poly(o-anisidine)/graphene oxide nanosheets composite as a coating for the headspace solid-phase microextraction of benzene, toluene, ethylbenzene and xylenes.

    Science.gov (United States)

    Behzadi, Mansoureh; Mirzaei, Mohammad

    2016-04-22

    A poly(o-anisidine)/graphene oxide nanosheets (PoA/GONSs) coating is fabricated by a simple and efficient electrochemical deposition method on steel wire. The incorporation of PoA and GONSs allows preparing a nanocomposite that can successfully integrate the advantages of both. Then, the prepared fiber is applied to the headspace solid-phase microextraction (HS-SPME) and gas chromatographic analysis of benzene, toluene, ethylbenzene and xylenes. In order to obtain an adherent, stable and efficient fiber to extract target analytes, experimental parameters related to the coating process such as deposition potential, deposition time, concentration of the monomer and concentration of GONSs were studied. The prepared composite fiber were characterized by Fourier transform infrared spectroscopy, powder X-ray diffraction and scanning electron microscopy. The effect of various parameters on the efficiency of HS-SPME process consisting of desorption temperature and time, extraction temperature and time and ionic strength were also optimized. Under the optimal conditions, the method was linear for orders of magnitude with correlation coefficients varying from 0.9888 to 0.9993. Intra- and inter-day precisions of the method were determined from mixed aqueous solutions containing 5.0 ng mL(-1) of each BTEX. The intra-day precisions varied from 3.1% for toluene to 5.7% for ethylbenzene, while the inter-day precisions varied from 4.9% for o-xylene to 7.3% for m,p-xylene. Limits of detection were in the range 0.01-0.06 ng mL(-1). The proposed method was applied to monitor BTEX compounds in some water samples and the accuracies found through spiking river water samples showed high recoveries between 92.0 and 101.2%. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. New Solid Phases for Estimation of Hormones by Radioimmunoassay Technique

    International Nuclear Information System (INIS)

    Sheha, R.R.; Ayoub, H.S.M.; Shafik, M.

    2013-01-01

    The efforts in this study were initiated to develop and validate new solid phases for estimation of hormones by radioimmunoassay (RIA). The study argued the successful application of different hydroxy apatites (HAP) as new solid phases for estimation of Alpha fetoprotein (AFP), Thyroid Stimulating hormone (TSH) and Luteinizing hormone (LH) in human serum. Hydroxy apatites have different alkali earth elements were successfully prepared by a well-controlled co-precipitation method with stoichiometric ratio value 1.67. The synthesized barium and calcium hydroxy apatites were characterized using XRD and Ftir and data clarified the preparation of pure structures of both BaHAP and CaHAP with no evidence on presence of other additional phases. The prepared solid phases were applied in various radioimmunoassay systems for separation of bound and free antigens of AFP, TSH and LH hormones. The preparation of radiolabeled tracer for these antigens was carried out using chloramine-T as oxidizing agent. The influence of different parameters on the activation and coupling of the used apatite particles with the polyclonal antibodies was systematically investigated and the optimum conditions were determined. The assay was reproducible, specific and sensitive enough for regular estimation of the studied hormones. The intra-and inter-assay variation were satisfactory and also the recovery and dilution tests indicated an accurate calibration. The reliability of these apatite particles had been validated by comparing the results that obtained by using commercial kits. The results finally authenticates that hydroxyapatite particles would have a great potential to address the emerging challenge of accurate quantitation in laboratory medical application

  3. Thermodynamic phase behavior of API/polymer solid dispersions.

    Science.gov (United States)

    Prudic, Anke; Ji, Yuanhui; Sadowski, Gabriele

    2014-07-07

    To improve the bioavailability of poorly soluble active pharmaceutical ingredients (APIs), these materials are often integrated into a polymer matrix that acts as a carrier. The resulting mixture is called a solid dispersion. In this work, the phase behaviors of solid dispersions were investigated as a function of the API as well as of the type and molecular weight of the carrier polymer. Specifically, the solubility of artemisinin and indomethacin was measured in different poly(ethylene glycol)s (PEG 400, PEG 6000, and PEG 35000). The measured solubility data and the solubility of sulfonamides in poly(vinylpyrrolidone) (PVP) K10 and PEG 35000 were modeled using the perturbed-chain statistical associating fluid theory (PC-SAFT). The results show that PC-SAFT predictions are in a good accordance with the experimental data, and PC-SAFT can be used to predict the whole phase diagram of an API/polymer solid dispersion as a function of the kind of API and polymer and of the polymer's molecular weight. This remarkably simplifies the screening process for suitable API/polymer combinations.

  4. Dynamic headspace solid-phase microextraction combined with one-dimensional gas chromatography-mass spectrometry as a powerful tool to differentiate banana cultivars based on their volatile metabolite profile.

    Science.gov (United States)

    Pontes, Marisela; Pereira, Jorge; Câmara, José S

    2012-10-15

    In this study the effect of the cultivar on the volatile profile of five different banana varieties was evaluated and determined by dynamic headspace solid-phase microextraction (dHS-SPME) combined with one-dimensional gas chromatography-mass spectrometry (1D-GC-qMS). This approach allowed the definition of a volatile metabolite profile to each banana variety and can be used as pertinent criteria of differentiation. The investigated banana varieties (Dwarf Cavendish, Prata, Maçã, Ouro and Platano) have certified botanical origin and belong to the Musaceae family, the most common genomic group cultivated in Madeira Island (Portugal). The influence of dHS-SPME experimental factors, namely, fibre coating, extraction time and extraction temperature, on the equilibrium headspace analysis was investigated and optimised using univariate optimisation design. A total of 68 volatile organic metabolites (VOMs) were tentatively identified and used to profile the volatile composition in different banana cultivars, thus emphasising the sensitivity and applicability of SPME for establishment of the volatile metabolomic pattern of plant secondary metabolites. Ethyl esters were found to comprise the largest chemical class accounting 80.9%, 86.5%, 51.2%, 90.1% and 6.1% of total peak area for Dwarf Cavendish, Prata, Ouro, Maçã and Platano volatile fraction, respectively. Gas chromatographic peak areas were submitted to multivariate statistical analysis (principal component and stepwise linear discriminant analysis) in order to visualise clusters within samples and to detect the volatile metabolites able to differentiate banana cultivars. The application of the multivariate analysis on the VOMs data set resulted in predictive abilities of 90% as evaluated by the cross-validation procedure. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Carbon nanotubes reinforced hollow fiber solid phase microextraction for the determination of strychnine and brucine in urine.

    Science.gov (United States)

    Song, Xin-Yue; Shi, Yan-Ping; Chen, Juan

    2013-11-15

    A mixed matrix membrane (MMM), based on carbon nanotubes (CNTs) and hollow fiber (HF), was prepared and combined with solid phase microextraction (SPME) mode to determine strychnine and brucine in urine. This MMM was prepared by dispersing CNTs in water via surfactant assistance, and then immobilizing CNTs into the pores of HF by capillary forces and sonification. The prepared carbon nanotubes reinforced hollow fiber (CNTs-HF) was subsequently wetted by a few microliters of organic solvent (1-octanol), and then applied to extract the target analytes in direct immersion sampling mode. After extraction, analytes were desorbed via ultrasonic-assisted effect, and then detected via high-performance liquid chromatography (HPLC). To achieve the highest extraction efficiency, main extraction parameters such as the type and amount of surfactant, the diameter and doping level of CNTs, extraction time, desorption condition, pH value, stirring rate and volume of the donor phase were optimized. Under the optimum extraction conditions, the method showed good linearity ranges with correlation coefficients higher than 0.9990, good repeatability and batch-to-batch reproducibility with relative standard deviations (RSDs) less than 6% and 5% for strychnine and brucine, respectively, and low limits of detection (0.7 and 0.9 µg L(-1) for strychnine and brucine, respectively). The recoveries were in the range of 83.81-116.14% at three spiked levels. The developed method was successfully applied to real urine sample with mean relative recoveries of 94.28% and 91.30% for strychnine and brucine, respectively. The developed method shows comparable results against reference methods and is a simple, green, and cost-effective microextraction technique. © 2013 Elsevier B.V. All rights reserved.

  6. Solid State NMR Studies of the Aluminum Hydride Phases

    Science.gov (United States)

    Hwang, Son-Jong; Bowman, R. C., Jr.; Graetz, Jason; Reilly, J. J.

    2006-01-01

    Several solid state NMR techniques including magic-angle-spinning (MAS) and multiple-quantum (MQ) MAS experiments have been used to characterize various AlH3 samples. MAS-NMR spectra for the 1H and 27Al nuclei have been obtained on a variety of AlH3 samples that include the (beta)- and (gamma)- phases as well as the most stable (alpha)-phase. While the dominant components in these NMR spectra correspond to the aluminum hydride phases, other species were found that include Al metal, molecular hydrogen (H2), as well as peaks that can be assigned to Al-O species in different configurations. The occurrence and concentration of these extraneous components are dependent upon the initial AlH3 phase composition and preparation procedures. Both the (beta)-AlH3 and (gamma)-AlH3 phases were found to generate substantial amounts of Al metal when the materials were stored at room temperature while the (alpha)-phase materials do not exhibit these changes.

  7. Novel solidsolid phase change material based on polyethylene glycol and cellulose used for temperature stabilisation

    Directory of Open Access Journals (Sweden)

    Wojda Marta

    2014-01-01

    Full Text Available Thermal management is one of crucial issues in the development of modern electronic devices. In the recent years interest in phase change materials (PCMs as alternative cooling possibility has increased significantly. Preliminary results concerning the research into possibility of the use of solid-solid phase change materials (S-S PCMs for stabilisation temperature of electronic devices has been presented in the paper. Novel solid-solid phase change material based on polyethylene glycol and cellulose has been synthesized. Attempt to improve its thermal conductivity has been taken. Material has been synthesized for the purpose of stabilisation of temperature of electronic devices.

  8. Sensitive and fast mutation detection by solid phase chemical cleavage

    DEFF Research Database (Denmark)

    Hansen, Lise Lotte; Justesen, Just; Kruse, Torben A

    1996-01-01

    We have developed a solid phase chemical cleavage method (SpCCM) for screening large DNA fragments for mutations. All reactions can be carried out in microtiterwells from the first amplification of the patient (or test) DNA through the search for mutations. The reaction time is significantly...... reduced compared to the conventional chemical cleavage method (CCM), and even by using a uniformly labelled probe, the exact position and nature of the mutation can be revealed. The SpCCM is suitable for automatization using a workstation to carry out the reactions and a fluorescent detection-based DNA...

  9. Advances in solid-phase extraction disks for environmental chemistry

    Science.gov (United States)

    Thurman, E.M.; Snavely, K.

    2000-01-01

    The development of solid-phase extraction (SPE) for environmental chemistry has progressed significantly over the last decade to include a number of new sorbents and new approaches to SPE. One SPE approach in particular, the SPE disk, has greatly reduced or eliminated the use of chlorinated solvents for the analysis of trace organic compounds. This article discusses the use and applicability of various SPE disks, including micro-sized disks, prior to gas chromatography-mass spectrometry for the analysis of trace organic compounds in water. Copyright (C) 2000 Elsevier Science B.V.

  10. Measurement of mercury species in human blood using triple spike isotope dilution with SPME-GC-ICP-DRC-MS.

    Science.gov (United States)

    Sommer, Yuliya L; Verdon, Carl P; Fresquez, Mark R; Ward, Cynthia D; Wood, Elliott B; Pan, Yi; Caldwell, Kathleen L; Jones, Robert L

    2014-08-01

    The measurement of different mercury compounds in human blood can provide valuable information about the type of mercury exposure. To this end, our laboratory developed a biomonitoring method for the quantification of inorganic (iHg), methyl (MeHg), and ethyl (EtHg) mercury in whole blood using a triple-spike isotope dilution (TSID) quantification method employing capillary gas chromatography (GC) and inductively coupled dynamic reaction cell mass spectrometry (ICP-DRC-MS). We used a robotic CombiPAL(®) sample handling station featuring twin fiber-based solid-phase microextraction (SPME) injector heads. The use of two SPME fibers significantly reduces sample analysis cycle times making this method very suitable for high sample throughput, which is a requirement for large public health biomonitoring studies. Our sample preparation procedure involved solubilization of blood samples with tetramethylammonium hydroxide (TMAH) followed by the derivatization with sodium tetra(n-propyl)borate (NaBPr(4)) to promote volatility of mercury species. We thoroughly investigated mercury species stability in the blood matrix during the course of sample treatment and analysis. The method accuracy for quantifying iHg, MeHg, and EtHg was validated using NIST standard reference materials (SRM 955c level 3) and the Centre de Toxicologie du Québec (CTQ) proficiency testing (PT) samples. The limit of detection (LOD) for iHg, MeHg, and EtHg in human blood was determined to be 0.27, 0.12, and 0.16 μg/L, respectively.

  11. An Innovative Rapid Method for Analysis of 10 Organophosphorus Pesticide Residues in Wheat by HS-SPME-GC-FPD/MSD.

    Science.gov (United States)

    Du, Xin; Ren, YongLin; Beckett, Stephen J

    2016-01-01

    The rapid detection of pesticide residues in wheat has become a top food security priority. A solvent-free headspace solid-phase microextraction (HS-SPME) has been evaluated for rapid screening of organophosphorus pesticide (OPP) residues in wheat with high sensitivity. Individual wheat samples (1.7 g), spiked with 10 OPPs, were placed in a 4 mL sealed amber glass vial and heated at 60°C for 45 min. During this time, the OPP residues were extracted with a 50 μm/30 μm divinylbenzene (DVB)/carboxen (CAR)/plasma desorption mass spectroscopy polydimethylsiloxane (PDMS) fiber from the headspace above the sample. The fiber was then removed and injected into the GC injection port at 250°C for desorption of the extracted chemicals. The multiple residues were identified by a GC mass spectrometer detector (GC-MSD) and quantified with a GC flame photometric detector (GC-FPD). Seven spiked levels of 10 OPPs on wheat were analyzed. The GC responses for a 50 μm/30 μm DVB/CAR/PDMS fiber increased with increasing spiking levels, yielding significant (R(2) > 0.98) linear regressions. The lowest LODs of the multiple pesticide standards were evaluated under the conditions of the validation study in a range of levels from 0 (control) to 100 ng of pesticide residue per g of wheat that separated on a low-polar GC capillary column (Agilent DB-35UI). The results of the HS-SPME method were compared with the QuEChERS AOAC 2007.01 method and they showed several advantages over the latter. These included improved sensitivity, selectivity, and simplicity.

  12. Development and validation of automatic HS-SPME with a gas chromatography-ion trap/mass spectrometry method for analysis of volatiles in wines.

    Science.gov (United States)

    Paula Barros, Elisabete; Moreira, Nathalie; Elias Pereira, Giuliano; Leite, Selma Gomes Ferreira; Moraes Rezende, Claudia; Guedes de Pinho, Paula

    2012-11-15

    An automated headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-ion trap/mass spectrometry (GC-IT/MS) was developed in order to quantify a large number of volatile compounds in wines such as alcohols, ester, norisoprenoids and terpenes. The procedures were optimized for SPME fiber selection, pre-incubation temperature and time, extraction temperature and time, and salt addition. A central composite experimental design was used in the optimization of the extraction conditions. The volatile compounds showed optimal extraction using a DVB/CAR/PDMS fiber, incubation of 5 ml of wine with 2g NaCl at 45 °C during 5 min, and subsequent extraction of 30 min at the same temperature. The method allowed the identification of 64 volatile compounds. Afterwards, the method was validated successfully for the most significant compounds and was applied to study the volatile composition of different white wines. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. The dynamics of the HS/SPME-GC/MS as a tool to assess the spoilage of minced beef stored under different packaging and temperature conditions.

    Science.gov (United States)

    Argyri, Anthoula A; Mallouchos, Athanasios; Panagou, Efstathios Z; Nychas, George-John E

    2015-01-16

    The aim of the current study was to assess meat spoilage through the evolution of volatile compounds using chemometrics. Microbiological and sensory assessment, pH measurement and headspace solid phase microextraction gas chromatography/mass spectroscopy (headspace SPME-GC/MS) analysis were carried out in minced beef stored aerobically and under modified atmosphere packaging (MAP) at 0, 5, 10, and 15 °C. It was shown that the HS/SPME-GC/MS analysis provided useful information about a great number of volatile metabolic compounds detected during meat storage. Many of the identified and semi-quantified compounds were correlated with the sensory scores through the use of chemometrics, depicting possible spoilage indicators such as 2-pentanone, 2-nonanone, 2-methyl-1-butanol, 3-methyl-1-butanol, ethyl hexanoate, ethyl propanoate, ethyl lactate, ethyl acetate, ethanol, 2-heptanone, 3-octanone, diacetyl, and acetoin. Finally, the applied GC/MS global models were able to estimate the microbial counts of the different microorganisms and the sensory scores of a meat sample regardless of storage conditions (i.e. packaging and temperature). Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Powder metallurgy: Solid and liquid phase sintering of copper

    Science.gov (United States)

    Sheldon, Rex; Weiser, Martin W.

    1993-01-01

    Basic powder metallurgy (P/M) principles and techniques are presented in this laboratory experiment. A copper based system is used since it is relatively easy to work with and is commercially important. In addition to standard solid state sintering, small quantities of low melting metals such as tin, zinc, lead, and aluminum can be added to demonstrate liquid phase sintering and alloy formation. The Taguchi Method of experimental design was used to study the effect of particle size, pressing force, sintering temperature, and sintering time. These parameters can be easily changed to incorporate liquid phase sintering effects and some guidelines for such substitutions are presented. The experiment is typically carried out over a period of three weeks.

  15. Preparation, characterization, and applications of a novel solid-phase microextraction fiber by sol-gel technology on the surface of stainless steel wire for determination of poly cyclic aromatic hydrocarbons in aquatic environmental samples.

    Science.gov (United States)

    Es-haghi, Ali; Hosseininasab, Valiallah; Bagheri, Habib

    2014-02-27

    A novel solid-phase microextraction(SPME) fiber was prepared using sol-gel technology with ethoxylated nonylphenol as a fiber coating material. The fiber was employed to develop a headspace SPME-GC-MS method suitable for quantification of 13 polycyclic aromatic hydrocarbons (PAHs) in water samples. Surface characteristics of the fibers were inspected by energy dispersive X-ray (EDX) spectroscopy as well as by scanning electron microscopy (SEM). The SEM measurements showed the presence of highly porous nano-sized particles in the coating. Important parameters affecting the extraction efficiency such as extraction temperature and time, desorption conditions as well as ionic strength have been evaluated and optimized. In the next step, the validation of the new method have been performed, finding it to be specific in the trace analysis of PAHs, with the limit of detection (LOD) ranging from 0.01 to 0.5 μg L(-1) and the linear range from the respective LOD to 200 μg L(-1) with RSD amounting to less than 8%. The thermal stability of the fibers was investigated as well and they were found to be durable at 280°C for 345 min. Furthermore, the proposed method was successfully applied for quantification of PAHs in real water samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. A new strategy for synthesis of an in-tube molecularly imprinted polymer-solid phase microextraction device: selective off-line extraction of 4-nitrophenol as an example of priority pollutants from environmental water samples.

    Science.gov (United States)

    Zarejousheghani, Mashaalah; Möder, Monika; Borsdorf, Helko

    2013-10-10

    In this study a novel preparation protocol has been developed for the construction of an in-tube molecularly imprinted polymer-solid phase microextraction (MIP-SPME) device. Open tubular capillaries have been molded from a polymer sorbent imprinted for 4-nitrophenol as target molecule. Different parameters like inner diameter and volume of the polymer, porogen volume, swelling and shrinking effects of the polymer tubes, polymerization time, pH of the sample, extraction time, 'salting out' effect and serial connection of the tubes were evaluated and optimized. Particularly, an optimized polymer preparation process and extraction condition enhanced the final extraction recovery of 4-nitrophenol substantially. Using this new MIP-SPME technique with high-performance liquid chromatography-ultraviolet (HPLC-UV) analysis of the extracts, the linear range and the limits of detection and quantification are 0.001-10 mg L(-1), 0.33 μg L(-1) and 1.1 μg L(-1) respectively. At optimized conditions, a mixture of nitrophenols, alkylated and chlorinated phenols spiked into municipal waste water were analyzed to evaluate the matrix effects and cross selectivity of the new MIP capillary tubes. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Covalent Bonding of Metal-Organic Framework-5/Graphene Oxide Hybrid Composite to Stainless Steel Fiber for Solid-Phase Microextraction of Triazole Fungicides from Fruit and Vegetable Samples.

    Science.gov (United States)

    Zhang, Shuaihua; Yang, Qian; Wang, Wenchang; Wang, Chun; Wang, Zhi

    2016-04-06

    A hybrid material of the zinc-based metal-organic framework-5 and graphene oxide (metal-organic framework-5/graphene oxide) was prepared as a novel fiber coating material for solid-phase microextraction (SPME). The SPME fibers were fabricated by covalent bonding via chemical cross-linking between the coating material metal-organic framework-5/graphene oxide and stainless steel wire. The prepared fiber was used for the extraction of five triazole fungicides from fruit and vegetable samples. Gas chromatography coupled with microelectron capture detector (GC-μECD) was used for quantification. The developed method gave a low limit of detection (0.05-1.58 ng g(-1)) and good linearity (0.17-100 ng g(-1)) for the determination of the triazole fungicides in fruit and vegetable samples. The relative standard deviations (RSDs) for five replicate extractions of the triazole fungicides ranged from 3.7 to 8.9%. The method recoveries for spiked fungicides (5, 20, and 50 ng g(-1)) in grape, apple, cucumber, celery cabbage, pear, cabbage, and tomato samples were in the range of 85.6-105.8% with the RSDs ranging from 3.6 to 11.4%, respectively, depending on both the analytes and samples. The metal-organic framework-5/graphene oxide coated fiber was stable enough for 120 extraction cycles without a significant loss of extraction efficiency. The method was suitable for the determination of triazole fungicides in fruit and vegetable samples.

  18. Optimization of a novel method for determination of benzene, toluene, ethylbenzene, and xylenes in hair and waste water samples by carbon nanotubes reinforced sol-gel based hollow fiber solid phase microextraction and gas chromatography using factorial experimental design.

    Science.gov (United States)

    Es'haghi, Zarrin; Ebrahimi, Mahmoud; Hosseini, Mohammad-Saeid

    2011-05-27

    A novel design of solid phase microextraction fiber containing carbon nanotube reinforced sol-gel which was protected by polypropylene hollow fiber (HF-SPME) was developed for pre-concentration and determination of BTEX in environmental waste water and human hair samples. The method validation was included and satisfying results with high pre-concentration factors were obtained. In the present study orthogonal array experimental design (OAD) procedure with OA(16) (4(4)) matrix was applied to study the effect of four factors influencing the HF-SPME method efficiency: stirring speed, volume of adsorption organic solvent, extraction and desorption time of the sample solution, by which the effect of each factor was estimated using individual contributions as response functions in the screening process. Analysis of variance (ANOVA) was employed for estimating the main significant factors and their percentage contributions in extraction. Calibration curves were plotted using ten spiking levels of BTEX in the concentration ranges of 0.02-30,000ng/mL with correlation coefficients (r) 0.989-0.9991 for analytes. Under the optimized extraction conditions, the method showed good linearity (0.3-20,000ng/L), repeatability, low limits of detections (0.49-0.7ng/L) and excellent pre-concentration factors (185-1872). The best conditions which were estimated then applied for the analysis of BTEX compounds in the real samples. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Characterization of the Typical Potent Odorants in Chinese Roasted Sesame-like Flavor Type Liquor by Headspace Solid Phase Microextraction-Aroma Extract Dilution Analysis, with Special Emphasis on Sulfur-Containing Odorants.

    Science.gov (United States)

    Sha, Sha; Chen, Shuang; Qian, Michael; Wang, Chengcheng; Xu, Yan

    2017-01-11

    The aroma profile of Chinese roasted sesame-like flavor type liquor was investigated by means of headspace solid phase microextraction-aroma extract dilution analysis (HS-SPME-AEDA). Sixty-three odor-active regions were detected by HS-SPME-AEDA with flavor dilution (FD) factors >5, and 58 of these were further identified. Among them, ethyl hexanoate, 2-furfurylthiol, dimethyl trisulfide, 3-methylbutanal, ethyl butanoate, ethyl 2-methylbutanoate, ethyl pentanoate, and ethyl 4-methylpentanoate appeared with the highest FD factors. In particular, eight sulfur-containing odorants were identified to be potentially important to roasted sesame-like flavor type liquor. The concentration of these odor-active compounds was further quantitated by combination of four different quantitative measurements, and 36 odorants had concentrations higher than their corresponding odor thresholds. On the basis of the odor activity values (OAVs), 2-furfurylthiol (OAV 1182), dimethyl trisulfide (OAV 220), β-damascenone (OAV 116), and methional (OAV 99) could be responsible for the unique aroma of roasted sesame-like flavor type liquor. An aroma recombination model prepared by mixing 36 aroma compounds with OAVs >1 showed a good similarity to the aroma of the original roasted sesame-like flavor type liquor. For the first time, 2-furfurylthiol was determined to be a typical potent odorant in roasted sesame-like flavor type liquor by omission study.

  20. Determination of Δ9-tetrahydrocannabinol and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in water samples by solid-phase microextraction with on-fiber derivatization and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Racamonde, Inés; Villaverde-de-Sáa, Eugenia; Rodil, Rosario; Quintana, José Benito; Cela, Rafael

    2012-07-06

    A new method for the determination of two cannabinoids, Δ9-tetrahydrocannabinol (THC) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH), in wastewater samples is proposed using solid-phase microextraction (SPME) as extraction technique and gas chromatography coupled to mass spectrometry (GC-MS) as determination technique. Several parameters involved in SPME extraction were studied and optimized (time, temperature, volume, pH and ionic strength of sample, and type of fiber). Moreover two derivatization reagents, N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), were studied in depth, providing MSTFA the best results. The use of internal standard calibration (with their corresponding deuterated analogs) allows avoiding standard addition calibration for the quantification of samples. Under optimal conditions, limits of detection at low nanograms per liter were achieved (1.0 and 2.5 ng L⁻¹ for THC and THCCOOH respectively). Precision (RSDTHC and 50-153 ng L⁻¹ for THCCOOH) and an incomplete removal, which translates into their detection in the receiving river. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. A Simple Method for the Simultaneous Determination of Pharmaceuticals and Personal Care Products in River Sediment by Ultrasound-Assisted Extraction Followed by Solid-Phase Microextraction Coupled with Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Díaz, Alejandro; Peña-Alvarez, Araceli

    2017-10-01

    A simple method was developed using ultrasound-assisted extraction (UAE) combined with solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of eight different pharmaceuticals and personal care products (PPCPs) (ibuprofen, 2-benzyl-4-chlorophenol, naproxen, triclosan, ketoprofen, diclofenac, bisphenol A and estrone) in river sediment. UAE conditions were optimized involving extraction variables such as extraction solvent, extraction time, sample amount, extraction temperature, pH and salt addition. A 100 mg of sediment was extracted by optimized UAE process using 7 mL deionized water (pH 3) + 1% methanol as solvent, room temperature and 1 min extraction at 70% of amplitude. A 5 mL of supernatant was subsequently extracted by SPME; the extracted analytes were derivatized on fiber in head-space mode with N-methyl-N-(tertbutyldimethylsilyl) trifluoroacetamide and then analyzed by GC-MS. The developed method was evaluated by testing: precision (CV 0.98), recoveries (56-108%), limits of detection (simple and environmentally friendly, and provides straightforward analyses of these trace organic pollutants in sediment samples. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Development of a fiber coating based on molecular sol-gel imprinting technology for selective solid-phase micro extraction of caffeine from human serum and determination by gas chromatography/mass spectrometry.

    Science.gov (United States)

    Rajabi Khorrami, Afshin; Rashidpur, Amene

    2012-05-21

    In this work, a molecular sol-gel imprinting approach has been introduced to produce a fiber coating for selective direct immersion solid-phase microextraction (SPME) of caffeine. The polymerization mixture was composed of vinyl trimethoxysilane and methacrylic acid as vinyl sol-gel precursor and functional monomer, respectively. Caffeine was used as template molecule during polymerization process. The prepared fibers could be coupled directly to gas chromatography/mass spectrometry (GC/MS) and used for trace analysis of caffeine in a complex sample such as human serum. The parameters influencing SPME such as time, temperature and stirring speed were optimized. The prepared coating showed good selectivity towards caffeine in the presence of some structurally related compounds. Also, it offered high imprinting capability in comparison to bare fiber and non-imprinted coating. Linear range for caffeine detection was 1-80 μg mL(-1) and the limit of detection was 0.1 μg mL(-1). The intra-day and inter-day precisions of the peak areas for five replicates were 10 and 16%, respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. A platinized stainless steel fiber with in-situ coated polyaniline/polypyrrole/graphene oxide nanocomposite sorbent for headspace solid-phase microextraction of aliphatic aldehydes in rice samples.

    Science.gov (United States)

    Ghiasvand, Alireza; Nasirian, Afagh; Koonani, Samira; Nouriasl, Kolsoum

    2017-12-01

    The surface of a stainless steel fiber was made larger, porous and cohesive by platinizing for tight attachment of its coating. Then it was coated by a polyaniline/polypyrrole/graphene oxide (PANI/PP/GO) nanocomposite film using electrochemical polymerization. The prepared PANI/PP/GO fiber was used for headspace solid-phase microextraction (HS-SPME) of linear aliphatic aldehydes in rice samples followed by GC-FID determination. To achieve the highest extraction efficiency, various experimental parameters including extraction time and temperature, matrix modifier and desorption condition were studied. The linear calibration curves were obtained over the range of 0.05-20 μg g -1 (R 2  > 0.99) for C 4 -C 11 aldehydes. The limits of detection were found to be in the range of 0.01-0.04 μg g -1 . RSD values were calculated to be <7.4 and 10.7% for intra- and inter-day, respectively. The superiority of the prepared nanocomposite SPME fiber was established by comparison of its results with those obtained by polydimethylsiloxane, carbowax-divinylbenzene, divinylbenzene-carboxen-polydimethylsiloxane and polyacrylate commercial ones. Finally, the nanocomposite fiber was used to extract and determine linear aliphatic aldehydes in 18 rice samples. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Determination of fluoroquinolones in eggs using in-tube solid-phase microextraction coupled to high-performance liquid chromatography.

    Science.gov (United States)

    Huang, Jing-Fang; Lin, Bo; Yu, Qiong-Wei; Feng, Yu-Qi

    2006-03-01

    A simple, rapid, and sensitive method using in-tube solid-phase microextraction (in-tube SPME) based on poly(methacrylic acid-ethylene glycol dimethacrylate) (MAA-EGDMA) monolith coupled to HPLC with fluorescence and UV detection was developed for the determination of five fluoroquinolones (FQs). Ofloxacin (OFL), norfloxacin (NOR), ciprofloxacin (CIP), enrofloxacin (ENRO), and sarafloxacin (SARA) can be enriched and determined in the spiked eggs and albumins. CIP/ENRO in eggs and albumins of ENRO-treated hens were also studied using the proposed method. Only homogenization, dilution, and centrifugation were required before the sample was supplied to the in-tube microextraction, and no organic solvents were consumed in the procedures. Under the optimized extraction conditions, good extraction efficiency for the five FQs was obtained with no matrix interference in the process of extraction and the subsequent chromatographic separation. The detection limits (S/N=3) were found to be 0.1-2.6 ng g(-1) and 0.2-2.4 ng g(-1) in whole egg and egg albumin, respectively. Good linearity could be achieved over the range 2-500 ng mL(-1) for the five FQs with regression coefficients above 0.9995 in both whole egg and albumin. The reproducibility of the method was evaluated at three concentration levels, with the resulting relative standard deviations (RSDs) less than 7%. The method was successfully applied to the analysis of ENRO and its primary metabolite CIP in the eggs and albumins of ENRO-treated hens.

  5. Quantitative solid phase microextraction--gas chromatography mass spectrometry analysis of five megastigmatrienone isomers in aged wine.

    Science.gov (United States)

    Slaghenaufi, Davide; Perello, Marie-Claire; Marchand-Marion, Stéphanie; Tempere, Sophie; de Revel, Gilles

    2014-02-27

    Megastigmatrienone is a key flavor compound in tobacco. It has also been detected in wine, where it may contribute to a tobacco/incense aroma, but its importance and concentration in wines had never previously been evaluated. A method was developed and validated for quantifying the five megastigmatrienone isomers in red and white wines. Megastigmatrienone isomers were extracted by headspace solid-phase microextraction (HS-SPME), with a 65 μm film thickness polydimethylsiloxane-divinylbenzene (PDMS-DVB) fiber and analyzed using gas chromatography-mass spectrometry (GC/MS) in selected ion monitoring mode (SIM). Several parameters affecting the length of the adsorption process (i.e., adding salt, extraction time and extraction temperature) were tested. The optimum analytical conditions were established. The LOQ were between 0.06 μg L(-1) and 0.49 μg L(-1) for white wine and 0.11 μg L(-1) and 0.98 μg L(-1) for red wine, repeatability in both types of wine was less than 10% and recovery ranged from 96% for white wine to 94% for red wine. The five isomers of megastigmatrienone were quantified in red and white wines for the first time. Concentrations ranged from 2 μg L(-1) to 41 μg L(-1) in both red and white wines. Initial results revealed a link between wine aging and megastigmatrienone levels, indicating that megastigmatrienone may be a component in wine "bouquet". Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Critical Regimes of Two-Phase Flows with a Polydisperse Solid Phase

    CERN Document Server

    Barsky, Eugene

    2010-01-01

    This book brings to light peculiarities of the formation of critical regimes of two-phase flows with a polydisperse solid phase. A definition of entropy is formulated on the basis of statistical analysis of these peculiarities. The physical meaning of entropy and its correlation with other parameters determining two-phase flows are clearly defined. The interrelations and main differences between this entropy and the thermodynamic one are revealed. The main regularities of two-phase flows both in critical and in other regimes are established using the notion of entropy. This parameter serves as a basis for a deeper insight into the physics of the process and for the development of exhaustive techniques of mass exchange estimation in such flows. The book is intended for graduate and postgraduate students of engineering studying two-phase flows, and to scientists and engineers engaged in specific problems of such fields as chemical technology, mineral dressing, modern ceramics, microelectronics, pharmacology, po...

  7. Coupling of SPME with MCC/UV-IMS as a tool for rapid on-site detection of groundwater and surface water contamination

    Energy Technology Data Exchange (ETDEWEB)

    Walendzik, G.; Baumbach, J.I.; Klockow, D. [ISAS-Institute for Analytical Sciences, Dortmund (Germany)

    2005-08-01

    The combination of headspace solid phase microextraction (HS-SPME) [1] with fast chromatographic pre-separation by means of multi-capillary columns (MCC) coupled to an ion mobility spectrometer equipped with a 10.6 eV photoionisation source was applied to rapid on-site monitoring of ground and surface water contaminations. Under field conditions, water contaminants were directly detectable down to the upper {mu}g/L range. The potential of the developed method is illustrated by measurements of BTEX, naphthalene, chlorinated alkenes and chlorinated benzenes in water. Practical results from investigations of contaminated groundwater at a former gasworks site and groundwater from the site of a metal processing plant, focusing on the key substances benzene, naphthalene and tetrachloroethene, demonstrate the feasibility of the system for field studies. (orig.)

  8. System for exchange of hydrogen between liquid and solid phases

    Science.gov (United States)

    Reilly, J.J.; Grohse, E.W.; Johnson, J.R.; Winsche, W.E.

    1985-02-22

    The reversible reaction M + x/2 H/sub 2/ reversible MH/sub x/, wherein M is a reversible metal hydride former that forms a hydride MH/sub x/ in the presence of H/sub 2/, generally used to store and recall H/sub 2/, is found to proceed under an inert liquid, thereby reducing contamination, providing better temperature control, providing in situ mobility of the reactants, and increasing flexibility in process design. Thus, a slurry of particles of a metal hydride former with an inert solvent is subjected to a temperature and pressure controlled atmosphere containing H/sub 2/, to store hydrogen and to release previously stored hydrogen. The direction of the flow of the H/sub 2/ through the liquid is dependent upon the H/sub 2/ pressure in the gas phase at a given temperature. When the actual H/sub 2/ pressure is above the equilibrium absorption pressure of the respective hydride the reaction proceeds to the right, i.e., the metal hydride is formed and hydrogen is stored in the solid particle. When the actual pressure in the gas phase is below the equilibrium dissociation pressure of the respective hydride the reaction proceeds to the left, the metal hydride is decomposed and hydrogen is released into the gas phase.

  9. Packed in-tube solid phase microextraction with graphene oxide supported on aminopropyl silica: Determination of target triazines in water samples.

    Science.gov (United States)

    De Toffoli, Ana L; Fumes, Bruno H; Lanças, Fernando M

    2018-02-22

    On-line in-tube solid phase microextraction (in-tube SPME) coupled to high performance liquid chromatography and tandem mass spectrometry (HPLC-MS/MS) was successfully applied to the determination of selected triazines in water samples. The method based on the employment of a packed column containing graphene oxide (GO) supported on aminopropyl silica (Si) showed that the extraction phase has a high potential for triazines extraction aiming to its physical-chemical properties including ultrahigh specific surface area, good mechanical and thermal stability and high fracture strength. Injection volume and loading time were both investigated and optimized. The method validation using Si-GO to extract and concentrate the analytes showed satisfactory results, good sensitivity, good linearity (0.2-4.0 µg L -1 ) and low detection limits (1.1-2.9 ng L -1 ). The high extraction efficiency was determined with enrichment factors ranging from 1.2-2.9 for the lowest level, 1.3-4.9 intermediate level and 1.2-3.0 highest level (n = 3). Although the analytes were not detected in the real samples evaluated, the method has demonstrated to be efficient through its application in the analysis of spiked triazines in ground and mineral water samples.

  10. Solid phase microextraction of diclofenac using molecularly imprinted polymer sorbent in hollow fiber combined with fiber optic-linear array spectrophotometry

    Science.gov (United States)

    Pebdani, Arezou Amiri; Shabani, Ali Mohammad Haji; Dadfarnia, Shayessteh; Khodadoust, Saeid

    2015-08-01

    A simple solid phase microextraction method based on molecularly imprinted polymer sorbent in the hollow fiber (MIP-HF-SPME) combined with fiber optic-linear array spectrophotometer has been applied for the extraction and determination of diclofenac in environmental and biological samples. The effects of different parameters such as pH, times of extraction, type and volume of the organic solvent, stirring rate and donor phase volume on the extraction efficiency of the diclofenac were investigated and optimized. Under the optimal conditions, the calibration graph was linear (r2 = 0.998) in the range of 3.0-85.0 μg L-1 with a detection limit of 0.7 μg L-1 for preconcentration of 25.0 mL of the sample and the relative standard deviation (n = 6) less than 5%. This method was applied successfully for the extraction and determination of diclofenac in different matrices (water, urine and plasma) and accuracy was examined through the recovery experiments.

  11. Solid phase microextraction of diclofenac using molecularly imprinted polymer sorbent in hollow fiber combined with fiber optic-linear array spectrophotometry.

    Science.gov (United States)

    Pebdani, Arezou Amiri; Shabani, Ali Mohammad Haji; Dadfarnia, Shayessteh; Khodadoust, Saeid

    2015-08-05

    A simple solid phase microextraction method based on molecularly imprinted polymer sorbent in the hollow fiber (MIP-HF-SPME) combined with fiber optic-linear array spectrophotometer has been applied for the extraction and determination of diclofenac in environmental and biological samples. The effects of different parameters such as pH, times of extraction, type and volume of the organic solvent, stirring rate and donor phase volume on the extraction efficiency of the diclofenac were investigated and optimized. Under the optimal conditions, the calibration graph was linear (r(2)=0.998) in the range of 3.0-85.0 μg L(-1) with a detection limit of 0.7 μg L(-1) for preconcentration of 25.0 mL of the sample and the relative standard deviation (n=6) less than 5%. This method was applied successfully for the extraction and determination of diclofenac in different matrices (water, urine and plasma) and accuracy was examined through the recovery experiments. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Investigation of the kinetics and microscopic mechanism of solid-solid phase transitions in HMX

    Science.gov (United States)

    Bowlan, Pamela; Suvorova, Natalya; Oschwald, Dave; Bowlan, John; Rector, Kirk; Henson, Bryan; Smilowitz, Laura

    2017-06-01

    Although studied intensely in the 2000's, a number of important questions about solid-solid phase transitions in the energetic organic material octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) remain. The mechanism by which one of the four isomorphs, known as δ, γ, α and β, transforms into another, and the conditions (i.e. temperature and pressure) and rates at which these transitions take place are still not fully known, yet important for predicting and controlling energy release phenomena in HMX such as detonation. The theory of virtual melting, by which a liquid forms at the interface of a nucleation site, is necessary to explain transformations between certain of the four different phases of HMX, such as the β to δ transition. However the existence of this disordered intermediate state has never been directly proven due to the need for both spatial (HMX using X-ray diffraction and confocal Raman and near-field infrared microscopy.

  13. Solid-solid synthesis and structural phase transition process of SmF3

    Science.gov (United States)

    Yan, Qi-Cao; Guo, Xing-Min

    2018-04-01

    Mazes of contradictory conclusions have been obtained by previous researches about structural phase transition process of SmF3. In this paper, the single crystals of SmF3 (hexagonal and orthorhombic) were prepared by solid-solid synthesis, which have shown gradual changes in crystal growth modes with the increase temperature and holding time. Furthermore, we propose the phase transition process of in SmF3. Hexagonal symmetry of SmF3 (space group Pnma) was prepared firstly by heating Sm2O3 and NH4HF2 over 40 min at 270 °C. And then orthorhombic symmetry of SmF3 (space group P63mc) was obtained by heating hexagonal symmetry over 10 h at 650 °C. The reaction of SmF3 (hexagonal) = SmF3 (orthorhombic) is extremely sluggish at a low temperature (less than 650 °C), which was seen as a Mixed Grown Region.

  14. Evaluation of stability of enalapril maleate in solid phase.

    Science.gov (United States)

    Stanisz, Beata

    2003-02-26

    The influence of temperature (from 383 to 348 K) and relative humidity (from 25.0 to 76.4%) on the stability of enalapril maleate in the solid phase was investigated. Changes in the concentration enalapril maleate were followed by a HPLC method with UV detection. The kinetic and thermodynamic parameters [E(a) (kJ mol(-1))=168.5+/-27 for RH=0% and 149.1+/-48 for RH=76.4%; deltaH(not equal ) (kJ mol(-1))=166.1+/-30 for RH=0% and 146.6+/-50 for RH=76.4%; deltaS(not equal) (J (K(-1) mol(-1)))=120.3+/-169 for RH=0% and 82.1+/-110 for RH=76.4%) of the decomposition reaction were calculated.

  15. Optimization of biological and instrumental detection of explosives and ignitable liquid residues including canines, SPME/ITMS and GC/MSn

    Science.gov (United States)

    Furton, Kenneth G.; Harper, Ross J.; Perr, Jeannette M.; Almirall, Jose R.

    2003-09-01

    A comprehensive study and comparison is underway using biological detectors and instrumental methods for the rapid detection of ignitable liquid residues (ILR) and high explosives. Headspace solid phase microextraction (SPME) has been demonstrated to be an effective sampling method helping to identify active odor signature chemicals used by detector dogs to locate forensic specimens as well as a rapid pre-concentration technique prior to instrumental detection. Common ignitable liquids and common military and industrial explosives have been studied including trinitrotoluene, tetryl, RDX, HMX, EGDN, PETN and nitroglycerine. This study focuses on identifying volatile odor signature chemicals present, which can be used to enhance the level and reliability of detection of ILR and explosives by canines and instrumental methods. While most instrumental methods currently in use focus on particles and on parent organic compounds, which are often involatile, characteristic volatile organics are generally also present and can be exploited to enhance detection particularly for well-concealed devices. Specific examples include the volatile odor chemicals 2-ethyl-1-hexanol and cyclohexanone, which are readily available in the headspace of the high explosive composition C-4; whereas, the active chemical cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) is not. The analysis and identification of these headspace 'fingerprint' organics is followed by double-blind dog trials of the individual components using certified teams in an attempt to isolate and understand the target compounds to which dogs are sensitive. Studies to compare commonly used training aids with the actual target explosive have also been undertaken to determine their suitability and effectiveness. The optimization of solid phase microextraction (SPME) combined with ion trap mobility spectrometry (ITMS) and gas chromatography/mass spectrometry/mass spectrometry (GC/MSn) is detailed including interface development

  16. Selectivity of solid-phase extraction phases in the determination of biodegradation products.

    Science.gov (United States)

    Bielicka, K; Voelkel, A

    2001-05-18

    The extraction techniques connected with gas chromatography were used to describe quantitatively and qualitatively the biodegradation process. We investigated the biodegradation of hydrocarbons and non-ionic surfactants. Solid-phase extraction (SPE) and liquid-liquid extraction were used for the isolation of the non-degraded compounds and their degradation products. The selectivity of SPE has a significant influence on the isolation and preconcentration of organic compounds from water.

  17. Municipal solid waste development phases: Evidence from EU27.

    Science.gov (United States)

    Vujić, Goran; Gonzalez-Roof, Alvaro; Stanisavljević, Nemanja; Ragossnig, Arne M

    2015-12-01

    Many countries in the European Union (EU) have very developed waste management systems. Some of its members have managed to reduce their landfilled waste to values close to zero during the last decade. Thus, European Union legislation is very stringent regarding waste management for their members and candidate countries, too. This raises the following questions: Is it possible for developing and developed countries to comply with the European Union waste legislation, and under what conditions? How did waste management develop in relation to the economic development in the countries of the European Union? The correlation between waste management practices and economic development was analysed for 27 of the European Union Member States for the time period between 1995 and 2007. In addition, a regression analysis was performed to estimate landfilling of waste in relation to gross domestic product for every country. The results showed a strong correlation between the waste management variables and the gross domestic product of the EU27 members. The definition of the municipal solid waste management development phases followed a closer analysis of the relation between gross domestic product and landfilled waste. The municipal solid waste management phases are characterised by high landfilling rates at low gross domestic product levels, and landfilling rates near zero at high gross domestic product levels. Hence the results emphasize the importance of wider understanding of what is required for developing countries to comply with the European Union initiatives, and highlight the importance of allowing developing countries to make their own paths of waste management development. © The Author(s) 2015.

  18. Development of novel solid-phase protein formulations

    Science.gov (United States)

    Montalvo Ortiz, Brenda Liz

    Proteins are the next-generation drugs for the treatment of several diseases. However, the number of protein drugs is still limited due to the physical or chemical instability of proteins during processing, formulation, storage, and delivery. The formulation of proteins at the solid state has advantages over liquid state, such as improved stability during long-term storage and delivery and decreases transportation costs. In this dissertation, we developed new solid-phase protein formulations in which the integrity of the protein was not compromised. The long term goal of this research was to use these protein formulations to improve protein stability in drug delivery devices, such as poly(lactic-co-glycolic) acid (PLGA). The first solid-phase protein formulation developed in this investigation was named "glassification". We proposed glassification as an alternative protein dehydration technique to the common used one, lyophilization, because this last method involves a series of steps which are detrimental to protein structure and stability. The glassification method consisted on protein dehydration by the use of organic solvents. As a result of the glassification process a small (micrometer size range) protein solid bead was obtained. The proteins used to study the glassification process were lysozyme (LYS), alpha-chymotrypsin (CHYMO) and horseradish peroxidase (HRP). These studies revealed that the glassification process itself did not alter protein structure and the activity was preserved. Ethyl acetate was the most effective organic solvent for protein glassification because it led to the highest protein residual activity, no insoluble aggregate formation and is a relatively non-toxic solvent, which allow the incorporation of these protein microparticles in PLGA microspheres. The incorporation of spherical HRP microparticles into PLGA microspheres resulted in superior properties when compared with encapsulated lyophilized HRP powder, such as improved release

  19. Study on confirmation of Solid-Meal Lag Phase of Gastric Emptying

    International Nuclear Information System (INIS)

    Lee, Ji Young; Lee, Kyoung Soo; Kim, Chang Guhn; Juhng, Seon Kwan; Won, Jong Jin; Nah, Yong Ho

    1991-01-01

    The purpose of this study was to examine the existence of a lag phase of gastric emptying of solid meals. We studied solid phase gastric emptying in 26 normal subject using continuous data acquisition for 30 minutes. Each ingested a 300 g meal containing 99m Tc-labeled scrambled egg (solid 150 g, milk 150 ml). Lag phase was determined by 1) inspection of the gastric emptying curve 2) time to a 2% decrease in stomach activity 3) the time of visual appearance of duodenal activity on computer image. We concluded that solid meal lag phase exist.

  20. Microencapsulated Comb-Like Polymeric Solid-Solid Phase Change Materials via In-Situ Polymerization

    Directory of Open Access Journals (Sweden)

    Wei Li

    2018-02-01

    Full Text Available To enhance the thermal stability and permeability resistance, a comb-like polymer with crystallizable side chains was fabricated as solid-solid phase change materials (PCMs inside the cores of microcapsules and nanocapsules prepared via in-situ polymerization. In this study, the effects on the surface morphology and microstructure of micro/nanocapsules caused by microencapsulating different types of core materials (i.e., n-hexadecane, ethyl hexadecanoate, hexadecyl acrylate and poly(hexadecyl acrylate were systematically studied via field emission scanning electron microscope (FE-SEM and transmission electron microscope (TEM. The confined crystallization behavior of comb-like polymer PCMs cores was investigated via differential scanning calorimeter (DSC. Comparing with low molecular organic PCMs cores, the thermal stability of PCMs microencapsulated comb-like polymer enhanced significantly, and the permeability resistance improved obviously as well. Based on these resultant analysis, the microencapsulated comb-like polymeric PCMs with excellent thermal stability and permeability resistance showed promising foreground in the field of organic solution spun, melt processing and organic coating.

  1. Microwave Enhanced Freeze Drying of Solid Waste, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Development of technology for Microwave Enhanced Freeze Drying of Solid Waste (MEFDSW) is proposed. The present state of the art for solid waste stabilization using...

  2. Polydopamine-based immobilization of a hydrazone covalent organic framework for headspace solid-phase microextraction of pyrethroids in vegetables and fruits.

    Science.gov (United States)

    Wu, Mingxue; Chen, Gang; Liu, Ping; Zhou, Weihong; Jia, Qiong

    2016-07-22

    We designed a novel hydrazone covalent organic framework (COF) and developed a polydopamine (PDA) method to immobilize COF on a stainless steel fiber for headspace solid-phase microextraction (HS-SPME). A series of characterization studies was performed to validate the structure and property of the prepared fiber. The COF-PDA fiber was applied for the extraction of pyrethroids coupled with gas chromatography equipped with an electron capture detector (GC-ECD). Under the optimum experimental conditions, high enhancement factors of 307-2327 were achieved, indicating that the hydrazone COF possessed good extraction efficiency for pyrethroids. The detection limits ranged from 0.11 to 0.23μgkg(-1) with relative standard deviations varying in the range of 3.6-9.2% (intra-batch) and 6.9-12.1% (inter-batch), respectively. The developed method was applied to the determination of pyrethroids in fruit and vegetable samples and the accuracy was assessed through recovery experiments. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Preparation of a polyacrylonitrile/multi-walled carbon nanotubes composite by surface-initiated atom transfer radical polymerization on a stainless steel wire for solid-phase microextraction.

    Science.gov (United States)

    Minet, Isabelle; Hevesi, Laszlo; Azenha, Manuel; Delhalle, Joseph; Mekhalif, Zineb

    2010-04-23

    We report on the fabrication and performances of a solid-phase microextraction (SPME) fiber based on a stainless steel wire coated with a covalently attached polyacrylonitrile (PAN)/multi-walled carbon nanotubes (MWCNTs) composite. This new coating is obtained by atom transfer radical polymerization (ATRP) of acrylonitrile mixed with MWCNTs. ATRP is initiated from 11-(2-bromo-2-methylpropionyloxy)-undecyl-phosphonic acid molecules grafted on the wire surface via the phosphonic acid group. The extraction performances of the fibers are assessed on different classes of compounds (polar, non-polar, aromatic, etc.) from water solutions by headspace extraction. The optimization of the parameters affecting the extraction efficiency of the target compounds was studied as well as the reproducibility and the repeatability of the fiber. The fibers sustain more than 200 extractions during which they remain chemically stable and maintain good performances (detection limits lower than 2 microg/l, repeatability, etc.). Considering their robustness together with their easy and inexpensive fabrication, these fibers could constitute promising alternatives to existing products. Copyright 2010 Elsevier B.V. All rights reserved.

  4. Simultaneous optimization by neuro-genetic approach of a multiresidue method for determination of pesticides in Passiflora alata infuses using headspace solid phase microextraction and gas chromatography.

    Science.gov (United States)

    da Silva, Gilmare Antônia; Augusto, Fabio; Poppi, Ronei Jesus

    2007-01-05

    A simultaneous optimization strategy based on neuro-genetic approach has been applied to a HS-SPME-GC-ECD (Headspace Solid Phase Microextraction coupled to Gas Chromatography with Electron Capture Detection) method for simultaneous determination of the pesticides chlorotalonil, methyl parathion, malathion, alpha-endosulfan and beta-endosulfan in herbal infusions of Passiflora alata (Dryander). Two types of extractive fibers were used: a home-made device coated by sol-gel process with polydimethylsiloxane-poly(vinyl alcohol) (PDMS/PVA) and a commercial PDMS. The effects of extraction parameters such as dilution of the infusion, extraction temperature and time, as well as sample ionic strength were evaluated through the Doehlert design. To find a model that could relate these extraction parameters with the extraction efficiency of all pesticide simultaneously, a Bayesian Regularized Artificial Neural Network (BRANN) approach was employed. Subsequently, Genetic Algorithm (GA) was applied to attain the optimum values from the model developed by the neural network. The use of the proposed approach allowed the determination of a single extraction condition that maximized the peak areas of all pesticides simultaneously, showing a promising and a suitable new procedure to the optimization process of complex analytical problems.

  5. A new and efficient Solid Phase Microextraction approach for analysis of high fat content food samples using a matrix-compatible coating.

    Science.gov (United States)

    De Grazia, Selenia; Gionfriddo, Emanuela; Pawliszyn, Janusz

    2017-05-15

    The current work presents the optimization of a protocol enabling direct extraction of avocado samples by a new Solid Phase Microextraction matrix compatible coating. In order to further extend the coating life time, pre-desorption and post-desorption washing steps were optimized for solvent type, time, and degree of agitation employed. Using optimized conditions, lifetime profiles of the coating related to extraction of a group of analytes bearing different physical-chemical properties were obtained. Over 80 successive extractions were carried out to establish coating efficiency using PDMS/DVB 65µm commercial coating in comparison with the PDMS/DVB/PDMS. The PDMS/DVB coating was more prone to irreversible matrix attachment on its surface, with consequent reduction of its extractive performance after 80 consecutive extractions. Conversely, the PDMS/DVB/PDMS coating showed enhanced inertness towards matrix fouling due to its outer smooth PDMS layer. This work represents the first step towards the development of robust SPME methods for quantification of contaminants in avocado as well as other fatty-based matrices, with minimal sample pre-treatment prior to extraction. In addition, an evaluation of matrix components attachment on the coating surface and related artifacts created by desorption of the coating at high temperatures in the GC-injector port, has been performed by GCxGC-ToF/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Bioinspired Polyelectrolyte-Assembled Graphene-Oxide-Coated C18 Composite Solid-Phase Microextraction Fibers for In Vivo Monitoring of Acidic Pharmaceuticals in Fish.

    Science.gov (United States)

    Qiu, Junlang; Chen, Guosheng; Liu, Shuqin; Zhang, Tianlang; Wu, Jiayi; Wang, Fuxin; Xu, Jianqiao; Liu, Yan; Zhu, Fang; Ouyang, Gangfeng

    2016-06-07

    A novel solid-phase microextraction (SPME) fiber was prepared by gluing poly(diallyldimethylammonium chloride) (PDDA) assembled graphene oxide (GO)-coated C18 composite particles (C18@GO@PDDA) onto a quartz fiber with polyaniline (PANI). The fiber surface coating was sequentially modified with bioinspired polynorepinephrine, which provided a smooth biointerface and makes the coating suitable for in vivo sampling. The novel custom-made coating was used to extract acidic pharmaceuticals, and high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) was employed for analysis. The custom-made coating exhibited a much higher extraction efficiency than the previously used commercial polydimethylsiloxane (PDMS) and polyacrylate (PA) coatings. The custom-made coating also possessed satisfactory stability (the relative standard deviations (RSDs) ranged from 1.60% to 10.3% for six sampling-desorption cycles), interfiber reproducibility (the RSDs ranged from 2.61% to 11.5%), and resistance to matrix effects. The custom-made fibers were used to monitor the presence of acid pharmaceuticals in dorsal-epaxial muscle of living fish, and satisfactory sensitivities (limits of detection ranged from 0.13 ng/g to 7.56 ng/g) were achieved. The accuracies were verified by the comparison with liquid extraction. Moreover, the novel fibers were successfully used to monitor the presence of acidic pharmaceuticals in living fish, which demonstrated that the custom-made fibers were feasible for possible long-term in vivo continuous pharmaceutical monitoring.

  7. Automated solid-phase peptide synthesis to obtain therapeutic peptides

    Directory of Open Access Journals (Sweden)

    Veronika Mäde

    2014-05-01

    Full Text Available The great versatility and the inherent high affinities of peptides for their respective targets have led to tremendous progress for therapeutic applications in the last years. In order to increase the drugability of these frequently unstable and rapidly cleared molecules, chemical modifications are of great interest. Automated solid-phase peptide synthesis (SPPS offers a suitable technology to produce chemically engineered peptides. This review concentrates on the application of SPPS by Fmoc/t-Bu protecting-group strategy, which is most commonly used. Critical issues and suggestions for the synthesis are covered. The development of automated methods from conventional to essentially improved microwave-assisted instruments is discussed. In order to improve pharmacokinetic properties of peptides, lipidation and PEGylation are described as covalent conjugation methods, which can be applied by a combination of automated and manual synthesis approaches. The synthesis and application of SPPS is described for neuropeptide Y receptor analogs as an example for bioactive hormones. The applied strategies represent innovative and potent methods for the development of novel peptide drug candidates that can be manufactured with optimized automated synthesis technologies.

  8. Dispersive solid phase micro-extraction of mercury(II from environmental water and vegetable samples with ionic liquid modified graphene oxide nanoparticles

    Directory of Open Access Journals (Sweden)

    Nasrollahpour Atefeh

    2017-01-01

    Full Text Available A new dispersive solid phase micro-extraction (dispersive-SPME method for separation and preconcentration of mercury(II using ionic liquid modified magnetic reduced graphene oxide (IL-MrGO nanoparticles, prior to the measurement by cold vapour atomic absorption spectrometry (CV-AAS has been developed. The IL-MrGO composite was characterized by Brunauer– Emmett–Teller method (BET for adsorption-desorption measurement, thermogravimetric analysis (TGA, powder X-ray diffraction (XRD and X-ray photoelectron spectroscopy (XPS. The method is based on the sorption of mercury( II on IL-MrGO nanoparticles due to electrostatic interaction and complex formation of ionic liquid part of IL-MrGO with mercury(II. The effect of experimental parameters for preconcentration of mercury(II, such as solution type, concentration and volume of the eluent, pH, time of the sorption and desorption, amount of the sorbent and coexisting ion concentration have been optimized. Under the optimized conditions, a linear response was obtained in the concentration range of 0.08–10 ng mL-1 with a determination coefficient of 0.9995. The limit of detection (LOD of the method at a signal to noise ratio of 3 was 0.01 ng mL-1. Intra-day and inter-day precisions were obtained equal to 3.4 and 4.5 %, respectively. The dispersive solid phase micro-extraction of mercury(II on IL-MrGO nanoparticles coupled with cold vapour atomic absorption spectrometry was successfully used for extraction and determination of mercury(II in water and vegetable samples.

  9. Analysis of luwak coffee volatile by using solid phase microextraction and gas chromatography (Analisa senyawa volatil kopi luwak dengan menggunakan mikroekstrasi fase padat dan kromatolgi gas.

    Directory of Open Access Journals (Sweden)

    Ariza Budi Tunjung Sari

    2012-08-01

    Full Text Available The approach to authenticate Luwak coffee is made through analysis of volatile compounds of luwak coffee. Luwak coffee bean from type of arabica obtained from Andungsari Plantation in Bondowoso district, East Java Province Indonesia, was wet processed and sundried prior to roasting step. As many as 120 g green bean was roasted at 170-220°C for 8-12 minutes until reached light brown colour (Agtron scale 65 and was ground prior to extraction. Volatile compounds of roasted Luwak arabica coffee bean were extracted by using solid phase microextraction (SPME at 60°C for 30 minutes. The extracted analyte was subsequently transferred into GC-FID system by splitless injection at 260°C with five minutes sampling time, continued with separation through 50% phenyl 50% dimethylpolysiloxane capillary column and oven temperature programmed from 60°C to 180°C with rate of 5°C/min. Resulted chromatogram shows major peaks mainly in Rt 8.360-9.981, and Rt 9.705-14.778, and minor peaks identified before Rt 10 and after Rt 24. Varied sample quantity ranged within 0.5-2.5 g produced chromatograms which were not significantly different (p=0.08. This research also observed the use of γ-picoline (4-methylpyridine as internal standard. It was showed that γ-picoline appeared at Rt 8.6~ without overlaying other peaks originated from sample. Concentration of γ-picoline at 0.05 μL/g, resulted separable peaks. These findings showed that the use of solid phase microextraction and GC-FID is capable to be apply for identification and quantification of Luwak coffee

  10. Complement fixation by solid phase immune complexes. Reduced capacity in SLE sera

    DEFF Research Database (Denmark)

    Baatrup, G; Jonsson, H; Sjöholm, A

    1988-01-01

    We describe an ELISA for assessment of complement function based on the capacity of serum to support fixation of complement components to solid phase immune complexes (IC). Microplates were coated with aggregated bovine serum albumin (BSA) followed by rabbit anti-BSA IgG. The solid phase IC were...

  11. Immunochemical cross-reactivity between albumin and solid-phase adsorbed histamine

    DEFF Research Database (Denmark)

    Poulsen, L K; Nolte, H; Søndergaard, I

    1990-01-01

    For production of an antibody against histamine, this was coupled to human serum albumin (HSA) and used for immunization of rabbits. To test the antiserum, an immunoradiometric assay was developed comprising solid-phase bound histamine, antisera and radiolabelled protein A. Titration and inhibition...... experiments revealed that histamine adsorbed onto a solid-phase could bind the antiserum. However, neither free histamine nor histamine coupled to unrelated carriers could inhibit the binding of antiserum to the solid-phase histamine. Cross-reactivity was demonstrated between HSA and solid-phase bound...... histamine, as the immunoradiometric assay was inhibited by HSA. This unexpected cross-reactivity was established, as a commercially available antiserum with specificity to HSA without histamine also bound to the solid-phase bound histamine. It is suggested that preparations of antibodies against histamine...

  12. Novel materials and methods for solid-phase extraction and liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Ambrose, Diana [Iowa State Univ., Ames, IA (United States)

    1997-06-24

    This report contains a general introduction which discusses solid-phase extraction and solid-phase micro-extraction as sample preparation techniques for high-performance liquid chromatography, which is also evaluated in the study. This report also contains the Conclusions section. Four sections have been removed and processed separately: silicalite as a sorbent for solid-phase extraction; a new, high-capacity carboxylic acid functionalized resin for solid-phase extraction; semi-micro solid-phase extraction of organic compounds from aqueous and biological samples; and the high-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve.

  13. Utilization of long duration high-volume sampling coupled to SPME-GC-MS/MS for the assessment of airborne pesticides variability in an urban area (Strasbourg, France) during agricultural application.

    Science.gov (United States)

    Liaud, Céline; Brucher, Michel; Schummer, Claude; Coscollà, Clara; Wolff, Hélène; Schwartz, Jean-Jacques; Yusà, Vicent; Millet, Maurice

    2016-10-02

    Atmospheric samples have been collected between 14 March and 12 September 2012 on a 2-week basis (15 days of sampling and exchange of traps each 7 days) in Strasbourg (east of France) for the analysis of 43 pesticides. Samples (particle and gas phases) were separately extracted using Accelerated Solvent Extraction (ASE) and pre-concentrated by Solid Phase Micro-Extraction (SPME) before analysis by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). Four SPME consecutive injections at distinct temperatures were made in order to increase the sensitivity of detection for the all monitored pesticides. Currently used detected pesticides can be grouped in four classes; those used in maize crops (acetochlor, benoxacor, dicamba, s-metolachlor, pendimethalin, and bromoxynil), in cereal crops (benoxacor, chlorothalonil, fenpropimorph, and propiconazole), in vineyards (tebuconazole), and as herbicides for orchards, meadows of green spaces (2,4-MCPA, trichlopyr). This is in accordance with the diversity of crops found in the Alsace region and trends observed are in accordance with the period of application of these pesticides. Variations observed permit also to demonstrate that the long time sampling duration used in this study is efficient to visualize temporal variations of airborne pesticides concentrations. Then, long time high-volume sampling could be a simple method permitting atmospheric survey of atmospheric contamination without any long analysis time and consequently low cost.

  14. MOLECULARLY IMPRINTED SOLID PHASE EXTRACTION FOR TRACE ANALYSIS OF DIAZINON IN DRINKING WATER

    Directory of Open Access Journals (Sweden)

    M. Rahiminejad ، S. J. Shahtaheri ، M. R. Ganjali ، A. Rahimi Forushani ، F. Golbabaei

    2009-04-01

    Full Text Available Amongst organophosphate pesticides, the one most widely used and common environmental contaminant is diazinon; thus methods for its trace analysis in environmental samples must be developed. Use of diazinon imprinted polymers such as sorbents in solid phase extraction, is a prominent and novel application area of molecular imprinted polymers. For diazinon extraction, high performance liquid chromatography analysis was demonstrated in this study. During optimization of the molecular imprinted solid phase extraction procedure for efficient solid phase extraction of diazinon, Plackett-Burman design was conducted. Eight experimental factors with critical influence on molecular imprinted solid phase extraction performance were selected, and 12 different experimental runs based on Plackett-Burman design were carried out. The applicability of diazinon imprinted polymers as the sorbent in solid phase extraction, presented obtained good recoveries of diazinon from LC-grade water. An increase in pH caused an increase in the recovery on molecular imprinted solid phase extraction. From these results, the optimal molecular imprinted solid phase extraction procedure was as follows: solid phase extraction packing with 100 mg diazinon imprinted polymers; conditioning with 5 mL of methanol and 6 mL of LC-grade water; sample loading containing diazinon (pH=10; washing with 1 mL of LC-grade water, 1 mL LC- grade water containing 30% acetonitrile and 0.5 mL of acetonitrile, respectively; eluting with 1 mL of methanol containing 2% acetic acid. The percentage recoveries obtained by the optimized molecular imprinted solid phase extraction were more than 90% with drinking water spiked at different trace levels of diazinon. Generally speaking, the molecular imprinted solid phase extraction procedure and subsequent high performance liquid chromatography analysis can be a relatively fast and proper approach for qualitative and quantitative analysis of diazinon in

  15. Determination of the oxidative stress biomarker urinary 8-hydroxy-2'-deoxyguanosine by automated on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Kataoka, Hiroyuki; Mizuno, Keisuke; Oda, Eri; Saito, Akihiro

    2016-04-15

    A simple and sensitive method for the determination of 8-hydroxy-2'-deoxyguanosine (8-OHdG), a marker of oxidative DNA damage in human urine, was developed using automated on-line in-tube solid-phase microextraction (SPME) coupled with stable isotope-dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS). Creatinine was also analyzed simultaneously to normalize urine volume by the in-tube SPME LC-MS/MS method, and 8-OHdG and creatinine were separated within 3 min using a Zorbax Eclipse XDB-C8 column. Electrospray MS/MS for these compounds was performed on an API 4000 triple quadruple mass spectrometer in the positive ion mode by multiple reaction monitoring. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Carboxen 1006 PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. The calibration curve for 8-OHdG using its stable isotope-labeled internal standard was linear in the range of 0.05-10 ng/mL, and the detection limit was 8.3 pg/mL. The intra-day and inter-day precision (relative standard deviations) were below 3.1% and 9.6% (n=5), respectively. This method was applied successfully to the analysis of urine samples without any other pretreatment and interference peaks, with good recovery rates above 91% in spiked urine samples. The limits of quantification of 8-OHdG and creatinine in 0.1 mL urine samples were about 0.32 and 0.69 ng/mL (S/N=10), respectively. This method was utilized to assess the effects of smoking, green tea drinking and alcohol drinking on the urinary excretion of 8-OHdG. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Multiphase Modeling of Solid Rocket Motor Internal Environment, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Solid rocket motor (SRM) design requires thorough understanding of the slag accumulation process in order to: predict thrust continuity, optimize propellant...

  17. Highly Efficient, Durable Regenerative Solid Oxide Stack, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Precision Combustion, Inc. (PCI) proposes to develop a highly efficient regenerative solid oxide stack design. Novel structural elements allow direct internal...

  18. Analytic escrutineo for plaguicidas organofosforados in blood in forensic cases by means of SPME-GC/NPD

    International Nuclear Information System (INIS)

    Fernandez Quesada, K.; Saenz Ugalde, M. F.

    2003-01-01

    The plaguicidas organophosphorus represent one of the most important causes of intoxication in Costa Rica; 20% of the cases received in the Section of Toxicology of the Department of Forensic Sciences of the Organism of Judicial Investigation (OIJ) are related to these plaguicidas. At the present time, the employed techniques in this institution to carry out the organophosphorus analyses in blood, present important limitations in their analytic potential. As a consequence, it is necessary to look for new methodologies, with the purpose to obtain a great specificity, and to diminish the limits of detection. This would allow a more qualified service that assures the validity and reliability of the results. Besides, it is an ideal instrument for the correct administration of justice of the Judicial Authorities. In this final work of graduation, it develops a methodology for the scrutiny of pesticides organophosphorus, in which a sample of biological origin of forensic importance is used. This employs a technique of quick, simple and clean extraction, using a separation method of detection of high analytic sensibility. In the methodology's development, samples of total blood, and the microextraccion techniques in solid phase will be used (SPME), and detection with gas chromatography by a specific instrumental detector of match and nitrogen (GCINPD) [es

  19. [Difference of volatile constituents contained in female and male flowers of Trichosanthes kirilowii by HS-SPME-GC-MS].

    Science.gov (United States)

    Sun, Wen; Chao, Zhimao; Wang, Chun; Wu, Xiaoyi; Tan, Zhigao

    2012-06-01

    To compare and analyze volatile constituents from flowers of Trichosanthes kirilowii, in order to point out characteristic differences between female and male flowers. Blooming female and male flowers were collected in the same place. Volatile constituents were extracted from the flower by solid phase micro-extraction (SPME), then separated and analyzed by gas chromatography-mass-spectrometry (GC-MS). Fifty-two and forty-five chromatographic peaks were separated from the female and male flowers, respectively. Forty seven constituents were identified and their relative percentage compositions were determined with the peak area normalization method. Linalool, alpha-farnesene, benzene methanol, and (Z)-2-methylbutanal oxime were the main volatile constituents. The contents of linalool and alpha-farnesene in female flower were remarkably higher than those in male. In contrast, the content of benzene methanol in male flower was remarkably higher than that in female. In the first study on chemical constituents from flowers in genus Trichosanthes, 37 compounds are separated from T. kirilowii. Contents of linalool, alpha-farnesene and benzene methanol show the characteristic differences of volatile constituents contained in male and female flowers of T. kirilowii, which enriches the basic studies on dioecious plant.

  20. Experimental design-based isotope-dilution SPME-GC/MS method development for the analysis of smoke flavouring products.

    Science.gov (United States)

    Giri, Anupam; Zelinkova, Zuzana; Wenzl, Thomas

    2017-12-01

    For the implementation of Regulation (EC) No 2065/2003 related to smoke flavourings used or intended for use in or on foods a method based on solid-phase micro extraction (SPME) GC/MS was developed for the characterisation of liquid smoke products. A statistically based experimental design (DoE) was used for method optimisation. The best general conditions to quantitatively analyse the liquid smoke compounds were obtained with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre, 60°C extraction temperature, 30 min extraction time, 250°C desorption temperature, 180 s desorption time, 15 s agitation time, and 250 rpm agitation speed. Under the optimised conditions, 119 wood pyrolysis products including furan/pyran derivatives, phenols, guaiacol, syringol, benzenediol, and their derivatives, cyclic ketones, and several other heterocyclic compounds were identified. The proposed method was repeatable (RSD% method proved to be fit for purpose, allowing the rapid identification and quantification of volatile compounds in liquid smoke flavourings.

  1. Ultrarapid mutation detection by multiplex, solid-phase chemical cleavage

    Energy Technology Data Exchange (ETDEWEB)

    Rowley, G.; Saad, S.; Giannelli, F.; Green, P.M. [Guy`s & St. Thomas`s Hospitals, London (United Kingdom)

    1995-12-10

    The chemical cleavage of mismatches in heteroduplexes formed by probe and test DNA detects and locates any sequence change in long DNA segments ({approximately}1.8 kb), and its efficiency has been well tested in the analysis of both average (e.g., coagulation factor IX) and large, complex genes (e.g., coagulation factor VIII and dystrophin). In the latter application RT/PCR products allow the examination of all essential sequences of the gene in a minimum number of reactions. We use two specific chemical reactants (hydroxylamine and osmium tetroxide) and piperidine cleavage of the above procedure to develop a very fast mutation screening method. This is based on: (1) 5{prime} or internal fluorescent labeling to allow concurrent screening of three to four DNA fragments and (2) solid-phase chemistry to use a microliter format and reduce the time required for the procedure, from amplification of sequence to gel loading inclusive, to one person-working-day. We test the two variations of the method, one entailing 5{prime} labeling of probe DNA and the other uniform labeling of both probe and target DNA, by detecting 114 known hemophilia B (coagulation factor IX) mutations and by analyzing 129 new patients. Uniform labeling of both probe and target DNA prior to formation of the heteroduplexes leads to almost twofold redundancy in the ability to detect mutations. Alternatively, the latter procedure may offer very efficient though less than 100% screening for sequence changes with only hydroxylamine. The full method with two chemical reactions (hydroxylamine and osmium tetroxide) should allow one person to screen with virtually 100% accuracy more than 300 kb of sequence in three ABI 373 gels in 1 day. 26 refs., 7 figs., 1 tab.

  2. Solid phase exchange labeling of I-123-HIPDM

    International Nuclear Information System (INIS)

    Mangner, T.; Rogers, W.L.; Wieland, D.; Clinthorne, N.; Juni, J.; Koral, K.; Mayans, R.; Swanson, D.

    1984-01-01

    Reported brain uptake of the I-123 diamine, HIPDM, ranges from 3.5% to 8.5% of the injected dose. This variability has been attributed to varying purity of the labeled compound produced by published methods. The authors have obtained excellent radioiodide incorporation into HIPDM using a simple, 5-minute, solid-phase exchange reaction in the presence of ammonium sulfate or bisulfate. However, when ammonium sulfate was used, HPLC analysis (μBodapak-phenyl; 1% ammonium acetate (pH 5.5)/methanol, 30/70) revealed the presence of, in addition to labeled HIPDM and unreacted radioiodide, two additional labeled compounds, each comprising 4% of the total activity. Lowering the initial pH of the reaction by the use of ammonium bisulfate resulted in quantitative radioiodide incorporation to give chromatographically pure HIPDM. To date, this preparation has been tested in one normal human. Percent uptake in brain was determined by tomographic imaging with both a single photon ring tomograph (SPRINT) and rotating Anger camera (GE 400-T). In each case high energy background was determined by acquiring data with lead shielding over the collimator. This background was then subtracted from the images. Calibration was performed by imaging a 19 cm diameter uniform cylindrical phantom filled with I-123. Both sets of images were attenuation corrected with the Sorenson method. Total uptake in the brain was between 6.7% and 7.2% depending upon selection of the brain outline. This agrees with values reported previously and is quite comparable to those measured for iodoamphetamine

  3. Effectiveness of different solid-phase microextraction fibres for differentiation of selected Madeira island fruits based on their volatile metabolite profile--identification of novel compounds.

    Science.gov (United States)

    Pereira, João; Pereira, Jorge; Câmara, José S

    2011-01-15

    A headspace solid-phase microextraction (HS-SPME) procedure based on five commercialised fibres (85 μm polyacrylate - PA, 100 μm polydimethylsiloxane - PDMS, 65 μm polydimethylsiloxane/divinylbenzene - PDMS/DVB, 70 μm carbowax/divinylbenzene - CW/DVB and 85 μm carboxen/polydimethylsiloxane - CAR/PDMS) is presented for the characterization of the volatile metabolite profile of four selected Madeira island fruit species, lemon (Citrus limon), kiwi (Actinidia deliciosa), papaya (Carica papaya L.) and Chickasaw plum (Prunus angustifolia). The isolation of metabolites was followed by thermal desorption gas chromatography-quadrupole mass spectrometry (GC-qMS) methodology. The performance of the target fibres was evaluated and compared. The SPME fibre coated with CW/DVB afforded the highest extraction efficiency in kiwi and papaya pulps, while in lemon and plum the same was achieved with PMDS/DVB fibre. This procedure allowed for the identification of 80 compounds, 41 in kiwi, 24 in plums, 23 in papaya and 20 in lemon. Considering the best extraction conditions, the most abundant volatiles identified in kiwi were the intense aldehydes and ethyl esters such as (E)-2-hexenal and ethyl butyrate, while in Chicasaw plum predominate 2-hexenal, 2-methyl-4-pentenal, hexanal, (Z)-3-hexenol and cyclohexylene oxide. The major compounds identified in the papaya pulp were benzyl isothiocyanate, linalool oxide, furfural, hydroxypropanone, linalool and acetic acid. Finally, lemon was shown to be the most divergent of the four fruits, being its aroma profile composed almost exclusively by terpens, namely limonene, γ-terpinene, o-cymene and α-terpinolene. Thirty two volatiles were identified for the first time in the fruit or close related species analysed and 14 volatiles are reported as novel volatile metabolites in fruits. This includes 5 new compounds in kiwi (2-cyclohexene-1,4-dione, furyl hydroxymethyl ketone, 4-hydroxydihydro-2(3H)-furanone, 5-acetoxymethyl-2-furaldehyde and

  4. Headspace solid-phase microextraction-gas chromatographic-time-of-flight mass spectrometric methodology for geographical origin verification of coffee

    International Nuclear Information System (INIS)

    Risticevic, Sanja; Carasek, Eduardo; Pawliszyn, Janusz

    2008-01-01

    Increasing consumer awareness of food safety issues requires the development of highly sophisticated techniques for the authentication of food commodities. The food products targeted for falsification are either products of high commercial value or those produced in large quantities. For this reason, the present investigation is directed towards the characterization of coffee samples according to the geographical origin. The conducted research involves the development of a rapid headspace solid-phase microextraction (HS-SPME)-gas chromatography-time-of-flight mass spectrometry (GC-TOFMS) method that is utilized for the verification of geographical origin traceability of coffee samples. As opposed to the utilization of traditional univariate optimization methods, the current study employs the application of multivariate experimental designs to the optimization of extraction-influencing parameters. Hence, the two-level full factorial first-order design aided in the identification of two influential variables: extraction time and sample temperature. The optimum set of conditions for the two variables was 12 min and 55 deg. C, respectively, as directed by utilization of Doehlert matrix and response surface methodology. The high-throughput automated SPME procedure was completed by implementing a single divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) 50/30 μm metal fiber with excellent durability properties ensuring the completion of overall sequence of coffee samples. The utilization of high-speed TOFMS instrument ensured the completion of one GC-MS run of a complex coffee sample in 7.9 min and the complete list of benefits provided by ChromaTOF software including fully automated background subtraction, baseline correction, peak find and mass spectral deconvolution algorithms was exploited during the data evaluation procedure. The combination of the retention index (RI) system using C 8 -C 40 alkanes and the mass spectral library search was utilized for the

  5. Development of a rapid and sensitive method for the simultaneous determination of 1,2-dibromoethane, 1,4-dichlorobenzene and naphthalene residues in honey using HS-SPME coupled with GC-MS.

    Science.gov (United States)

    Tsimeli, K; Triantis, T M; Dimotikali, D; Hiskia, A

    2008-06-09

    A new method for the simultaneous determination of 1,4-dichlorobenzene (p-DCB), naphthalene and 1,2-dibromoethane (1,2-DBE) residues in honey has been developed. Analysis is carried out using gas chromatography-mass spectrometry (GC/MS) in selected ion monitoring mode (SIM), after extraction and preconcentration of target analytes by headspace solid-phase microextraction (HS-SPME), with a 100 microm film thickness polydimethylsiloxane (PDMS) fiber. Several parameters affecting the extension of the adsorption process (i.e., addition of salt, extraction time, extraction temperature) were studied. The optimal conditions for the determination of these analytes were established. The proposed HS-SPME method showed good sensitivity, without carryover between the samples. Linearity was studied from 5 to 2500 microg kg(-1) for p-DCB, 0.5 to 500 microg kg(-1) for naphthalene and 5 to 500 microg kg(-1) honey for 1,2-DBE with correlation coefficients (r(2)) ranging from 0.9901 to 0.9999. Precision was assessed and both intra and inter-day R.S.D.s (%) were below 6.3%. The detection limits were found to be 1, 0.1 and 2 microg kg(-1) honey for p-DCB, naphthalene and 1,2-DBE, respectively. The percentage recoveries that were evaluated with the proposed HS-SPME method and the standard addition calibration technique gave values among 72.8 and 104.3% for measurements in samples spiked with one target analyte or mixtures of the three. This method has been applied for the analysis of unknown honey samples. The results showed an excellent applicability of the proposed method for the determination of the target compounds in honey samples.

  6. Materials research for passive solar systems: solid-state phase-change materials

    Energy Technology Data Exchange (ETDEWEB)

    Benson, D.K.; Webb, J.D.; Burrows, R.W.; McFadden, J.D.O.; Christensen, C.

    1985-03-01

    A set of solid-state phase-change materials is being evaluated for possible use in passive solar thermal energy storage systems. The most promising materials are organic solid solutions of pentaerythritol (C/sub 5/H/sub 12/O/sub 4/), pentaglycerinve (C/sub 5/H/sub 12/O/sub 3/), and neopentyl glycol (C/sub 5/H/sub 12/O/sub 2/). Solid solution mixtures of these compounds can be tailored so that they exhibit solid-to-solid phase transformations at any desired temperature betweeen 25/sup 0/C and 188/sup 0/C, and have latent heats of transformation between 20 and 70 cal/g. Transformation temperatures, specific heats, and latent heats of transformation have been measured for a number of these materials. Limited cyclic experiments suggest that the solid solutions are stable. These phase-change materials exhibit large amounts of undercooling; however, the addition of certain nucleating agents as particulate dispersions in the solid phase-change material greatly reduces this effect. Computer simulations suggest that the use of an optimized solid-state phase-change material in a Trombe wall could provide better performance than a concrete Trombe wall four times thicker and nine times heavier. Nevertheless, a higher cost of the phase-change materials (approx. =$0.70 per pound) is likely to limit their applicability in passive solar systems unless their performance can be significantly improved through further research.

  7. Monitoring biogenic volatile compounds emitted by Eucalyptus citriodora using SPME.

    Science.gov (United States)

    Zini, C A; Augusto, F; Christensen, T E; Smith, B P; Caramão, E B; Pawliszy, J

    2001-10-01

    A procedure to monitor BVOC emitted by living plants using SPME technique is presented. For this purpose, a glass sampling chamber was designed. This device was employed for the characterization of biogenic volatile compounds emitted by leaves of Eucalyptus citriodora. After extraction with SPME fibers coated with PDMS/ DVB, it was possible to identify or detect 33 compounds emitted by this plant. A semiquantitative approach was applied to monitor the behavior of the emitted BVOC during 9 days. Circadian profiles of the variation in the concentration of isoprene were plotted. Using diffusion-based SPME quantitation, a recently introduced analytical approach, with extraction times as short as 15 s, it was possible to quantify subparts-per-billion amounts of isoprene emitted by this plant.

  8. Solid State MEMS Thrusters Using Electrically Controlled Extinguishable Solid Propellant, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — ET Materials, LLC developed the first ever electrically controlled extinguishable solid propellant (ECESP). The original propellant developed under Air Force SBIR...

  9. Insight into solid-liquid phase transfer catalyzed synthesis of ...

    Indian Academy of Sciences (India)

    Ganapati D Yadav

    2017-11-16

    TEAB) were screened ..... ion-pair with phenoxide species leading to the formation of potassium salt with K and KHCO3. The ..... on solid potassium carbonate surface under PTC circum- stances Heteroatom Chem. 15 447. 15.

  10. Microwave Enhanced Freeze Drying of Solid Waste, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The development of advanced methods for Microwave Enhanced Freeze Drying of Solid Waste (MEFDSW) is proposed. Methods for the recovery of relatively pure water as a...

  11. Solid State Oxygen Concentrator and Compressor, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Sustainable Innovations has developed a novel solid state technology for gas separation and will be applying it for the first time to meet a critical life support...

  12. NMR investigation of acrolein stability in hydroalcoholic solution as a foundation for the valid HS-SPME/GC–MS quantification of the unsaturated aldehyde in beverages

    Energy Technology Data Exchange (ETDEWEB)

    Kächele, Martin [Chemisches und Veterinäruntersuchungsamt (CVUA) Karlsruhe, Weissenburger Strasse 3, D-76187 Karlsruhe (Germany); Hochschule Mannheim, Paul-Wittsack-Strasse 10, D-68163 Mannheim (Germany); Monakhova, Yulia B. [Chemisches und Veterinäruntersuchungsamt (CVUA) Karlsruhe, Weissenburger Strasse 3, D-76187 Karlsruhe (Germany); Bruker Biospin GmbH, Silbersteifen, 76287 Rheinstetten (Germany); Department of Chemistry, Saratov State University, Astrakhanskaya Street 83, 410012 Saratov (Russian Federation); Kuballa, Thomas [Chemisches und Veterinäruntersuchungsamt (CVUA) Karlsruhe, Weissenburger Strasse 3, D-76187 Karlsruhe (Germany); Lachenmeier, Dirk W., E-mail: lachenmeier@web.de [Chemisches und Veterinäruntersuchungsamt (CVUA) Karlsruhe, Weissenburger Strasse 3, D-76187 Karlsruhe (Germany); Ministry of Rural Affairs and Consumer Protection, Kernerplatz 10, 70182 Stuttgart (Germany)

    2014-04-01

    Highlights: • Acrolein in hydroalcoholic solution degrades to 1,3,3-propanetriol and 3-hydroxypropionaldehyde. • Hydroquinone (0.2%) at pH 3.0 stabilizes acrolein solutions. • Quantitative HS-SPME/GC–MS determination of acrolein in alcoholic beverages was developed (LOD 14 μg L⁻¹. • 6 of 117 samples had acrolein levels above the WHO threshold (1500 μg L⁻¹). Abstract: Acrolein (propenal) is found in many foods and beverages and may pose a health hazard due to its cytotoxicity. Considerable knowledge gaps regarding human exposure to acrolein exist, and there is a lack of reliable analytical methods. Hydroalcoholic dilutions prepared for calibration purposes from pure acrolein show considerable degradation of the compound and nuclear magnetic resonance (NMR) spectroscopy showed that 1,3,3-propanetriol and 3-hydroxypropionaldehyde are formed. The degradation can be prevented by addition of hydroquinone as stabilizer to the calibration solutions, which then show linear concentration-response behaviour required for quantitative analysis. The stabilized calibration solutions were used for quantitative headspace solid-phase microextraction/gas chromatography–mass spectrometry (HS-SPME/GC–MS) determination of acrolein in alcoholic beverages with a detection limit of 14 μg L⁻¹. Of 117 tested alcoholic beverages, 64 were tested positive with the highest incidence in grape marc spirits and whiskey (100%, mean 252 μg L⁻¹), followed by fruit spirits (86%, mean 591 μg/L⁻¹), tequila (86%, mean 404 μg L⁻¹), Asian spirits (43%, mean 54 μg L⁻¹) and wine (9%, mean 0.7 μg L⁻¹). Acrolein could not be detected in beer, vodka, absinthe and bottled water. Six of the fruit and grape marc spirits had acrolein levels above the World Health Organization (WHO) provisional tolerable concentration of 1.5 mg L⁻¹.

  13. NMR investigation of acrolein stability in hydroalcoholic solution as a foundation for the valid HS-SPME/GC–MS quantification of the unsaturated aldehyde in beverages

    International Nuclear Information System (INIS)

    Kächele, Martin; Monakhova, Yulia B.; Kuballa, Thomas; Lachenmeier, Dirk W.

    2014-01-01

    Highlights: • Acrolein in hydroalcoholic solution degrades to 1,3,3-propanetriol and 3-hydroxypropionaldehyde. • Hydroquinone (0.2%) at pH 3.0 stabilizes acrolein solutions. • Quantitative HS-SPME/GC–MS determination of acrolein in alcoholic beverages was developed (LOD 14 μg L −1 ). • 6 of 117 samples had acrolein levels above the WHO threshold (1500 μg L −1 ). - Abstract: Acrolein (propenal) is found in many foods and beverages and may pose a health hazard due to its cytotoxicity. Considerable knowledge gaps regarding human exposure to acrolein exist, and there is a lack of reliable analytical methods. Hydroalcoholic dilutions prepared for calibration purposes from pure acrolein show considerable degradation of the compound and nuclear magnetic resonance (NMR) spectroscopy showed that 1,3,3-propanetriol and 3-hydroxypropionaldehyde are formed. The degradation can be prevented by addition of hydroquinone as stabilizer to the calibration solutions, which then show linear concentration-response behaviour required for quantitative analysis. The stabilized calibration solutions were used for quantitative headspace solid-phase microextraction/gas chromatography–mass spectrometry (HS-SPME/GC–MS) determination of acrolein in alcoholic beverages with a detection limit of 14 μg L −1 . Of 117 tested alcoholic beverages, 64 were tested positive with the highest incidence in grape marc spirits and whiskey (100%, mean 252 μg L −1 ), followed by fruit spirits (86%, mean 591 μg/L −1 ), tequila (86%, mean 404 μg L −1 ), Asian spirits (43%, mean 54 μg L −1 ) and wine (9%, mean 0.7 μg L −1 ). Acrolein could not be detected in beer, vodka, absinthe and bottled water. Six of the fruit and grape marc spirits had acrolein levels above the World Health Organization (WHO) provisional tolerable concentration of 1.5 mg L −1

  14. Preparation and application of a poly (ionic liquid)-based molecularly imprinted polymer for multiple monolithic fiber solid-phase microextraction of phenolic acids in fruit juice and beer samples.

    Science.gov (United States)

    Chen, Lei; Huang, Xiaojia

    2017-10-23

    In this work, a new molecularly imprinted polymer (MIP) using a poly (ionic liquid) (PIL) as a functional monomer was prepared and utilized as the extraction medium of multiple monolithic fiber solid-phase microextraction (MMF-SPME). A PIL, 1-ally-3-vinylimidazolium chloride, was used as a functional monomer, and 3,4-dihydroxybenzenepropanoic acid (DBA) and ethylene dimethacrylate were chosen as the template molecule and cross-linker, respectively, to synthesize the PIL/MIP. Under the optimized preparation conditions, the recognition coefficient of PIL-MIP for DBA was as high as 11.6. The combination of PIL/MIP-MMF-SPME and high-performance liquid chromatography with diode array detection (HPLC/DAD) was developed for the sensitive determination of phenolic acids (PAs) in fruit juice and beer samples. Under the optimal conditions which were investigated in detail, the limits of detection (LODs, S/N = 3) for PAs in fruit juice were 0.024-0.24 μg L -1 , and the related values were 0.011-0.052 μg L -1 for the beer sample. The intra-day and inter-day precision (relative standard deviations, n = 4, %) at 1.0 and 100.0 μg L -1 spiking concentration were both less than 10%. In the analysis of PAs in fruit juice and beer samples, satisfactory recoveries and repeatability were achieved. In comparison with reported approaches, the proposed method exhibited some advantages including high selectivity, convenience, satisfactory sensitivity and environmental friendliness.

  15. Online analysis of five organic ultraviolet filters in environmental water samples using magnetism-enhanced monolith-based in-tube solid phase microextraction coupled with high-performance liquid chromatography.

    Science.gov (United States)

    Mei, Meng; Huang, Xiaojia

    2017-11-24

    Due to the endocrine disrupting properties, organic UV filters have been a great risk for humans and other organisms. Therefore, development of accurate and effective analytical methods is needed for the determination of UV filters in environmental waters. In this work, a fast, sensitive and environmentally friendly method combining magnetism-enhanced monolith-based in-tube solid phase microextraction with high-performance liquid chromatography with diode array detection (DAD) (ME-MB-IT/SPME-HPLC-DAD) for the online analysis of five organic UV filters in environmental water samples was developed. To extract UV filters effectively, an ionic liquid-based monolithic capillary column doped with magnetic nanoparticles was prepared by in-situ polymerization and used as extraction medium of online ME-MB-IT/SPME-HPLC-DAD system. Several extraction conditions including the intensity of magnetic field, sampling and desorption flow rate, volume of sample and desorption solvent, pH value and ionic strength of sample matrix were optimized thoroughly. Under the optimized conditions, the extraction efficiencies for five organic UV filters were in the range of 44.0-100%. The limits of detection (S/N=3) and limits of quantification (S/N=10) were 0.04-0.26μg/L and 0.12-0.87μg/L, respectively. The precisions indicated by relative standard deviations (RSDs) were less than 10% for both intra- and inter-day variabilities. Finally, the developed method was successfully applied to the determination of UV filters in three environmental water samples and satisfactory results were obtained. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. New insight on biological interaction analysis: new nanocrystalline mixed metal oxide SPME fiber for GC-FID analysis of BTEX and its application in human hemoglobin-benzene interaction studies.

    Directory of Open Access Journals (Sweden)

    Reza Hosseinzadeh

    Full Text Available Nanocrystalline mixed metal oxides (MMO of various metal cations were synthesized and were used for coating a piece of copper wire as a new high sensitive solid phase micro extraction (SPME fiber in extraction and determination of BTEX compounds from the headspace of aqueous samples prior to GC-FID analysis. Under optimum extraction conditions, the proposed fiber exhibited low detection limits, and quantification limits, good reproducibility, simple and fast preparation method, high fiber capacity and high thermal and mechanical durability. These are some of the most important advantages of the new fiber. The proposed fiber was used for human hemoglobin upon interaction with benzene. Binding isotherm, Scatchard and Klotz logarithmic plots were constructed using HS-SPME-GC data, accurately. The obtained binding isotherm analyzed using Hill method. The Hill parameters have been obtained by calculating saturation parameter from the ratio of measured chromatographic peak areas in the presence and absence of hemoglobin. In this interaction, Hill coefficient and Hill constant determined as (nH = 6.14 and log KH = 6.47 respectively. These results reveal the cooperativity of hemoglobin upon interaction with benzene.

  17. Development and validation of an SPME-GC method for a degradation kinetics study of propiconazole I, propiconazole II and tebuconazole in blueberries in Concordia, the main production area of Argentina.

    Science.gov (United States)

    Munitz, Martín S; Medina, María B; Montti, María I T

    2017-05-01

    An analytical method for the simultaneous determination of propiconazole isomers and tebuconazole residues in blueberries was developed using solid-phase microextraction (SPME) coupled to gas chromatography. Confirmation was performed by gas chromatography-mass spectrometry in selected-ion monitoring mode. The SPME fibre coating selected was CWX-DVB, and the pH was adjusted to 7 with NaOH. The method is selective with adequate precision and high accuracy and sensitivity. Recoveries ranged between 97.4% and 98.9% for all compounds; and detection and quantification limits were respectively 0.21 and 0.49 μg kg -1 for propiconazole I; 0.16 and 0.22 μg kg -1 for propiconazole II; and 0.16 and 0.48 μg kg -1 for tebuconazole. The degradation of these fungicides in blueberries followed first-order rate kinetics. The half-life times for flowering and fruit set applications were respectively 4.0 and 10.3 days for propiconazole I, 4.0 and 11.4 days for propiconazole II, and 3.5 and 12.4 days for tebuconazole.

  18. Preparation and evaluation of a novel molecularly imprinted polymer coating for selective extraction of indomethacin from biological samples by electrochemically controlled in-tube solid phase microextraction

    Energy Technology Data Exchange (ETDEWEB)

    Asiabi, Hamid [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Yamini, Yadollah, E-mail: yyamini@modares.ac.ir [Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran (Iran, Islamic Republic of); Seidi, Shahram; Ghahramanifard, Fazel [Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of)

    2016-03-24

    In the present work, an automated on-line electrochemically controlled in-tube solid-phase microextraction (EC-in-tube SPME) coupled with HPLC-UV was developed for the selective extraction and preconcentration of indomethacin as a model analyte in biological samples. Applying an electrical potential can improve the extraction efficiency and provide more convenient manipulation of different properties of the extraction system including selectivity, clean-up, rate, and efficiency. For more enhancement of the selectivity and applicability of this method, a novel molecularly imprinted polymer coated tube was prepared and applied for extraction of indomethacin. For this purpose, nanostructured copolymer coating consisting of polypyrrole doped with ethylene glycol dimethacrylate was prepared on the inner surface of a stainless-steel tube by electrochemical synthesis. The characteristics and application of the tubes were investigated. Electron microscopy provided a cross linked porous surface and the average thickness of the MIP coating was 45 μm. Compared with the non-imprinted polymer coated tubes, the special selectivity for indomethacin was discovered with the molecularly imprinted coated tube. Moreover, stable and reproducible responses were obtained without being considerably influenced by interferences commonly existing in biological samples. Under the optimal conditions, the limits of detection were in the range of 0.07–2.0 μg L{sup −1} in different matrices. This method showed good linearity for indomethacin in the range of 0.1–200 μg L{sup −1}, with coefficients of determination better than 0.996. The inter- and intra-assay precisions (RSD%, n = 3) were respectively in the range of 3.5–8.4% and 2.3–7.6% at three concentration levels of 7, 70 and 150 μg L{sup −1}. The results showed that the proposed method can be successfully applied for selective analysis of indomethacin in biological samples. - Graphical abstract: An automated on

  19. Utilizing ion-pairing hydrophilic interaction chromatography solid phase extraction for efficient glycopeptide enrichment in glycoproteomics

    DEFF Research Database (Denmark)

    Mysling, Simon; Palmisano, Giuseppe; Højrup, Peter

    2010-01-01

    Glycopeptide enrichment is a prerequisite to enable structural characterization of protein glycosylation in glycoproteomics. Here we present an improved method for glycopeptide enrichment based on zwitter-ionic hydrophilic interaction chromatography solid phase extraction (ZIC-HILIC SPE...

  20. Evaluation of a Solid Phase DNA Binding Matrix for Downstream PCR Analysis

    National Research Council Canada - National Science Library

    Bader, Douglas E; Fisher, Glen R; Stratilo, Chad W

    2005-01-01

    A commercially available solid-phase DNA binding matrix (FTA cards) was evaluated for its ability to capture and release DNA for downstream gene amplification and detection assays using polymerase chain reaction (PCR...

  1. Solid phase extraction of β-N-methylamino-L-alanine (BMAA) from ...

    African Journals Online (AJOL)

    2011-01-25

    N-methylamino-L-alanine, BMAA, cyanobacterial bloom, solid phase extraction. Introduction. The isolation of the neurotoxin BMAA from freshwater and marine cyanobacteria (Cox et al., 2005; Banack et al., 2007;. Esterhuizen ...

  2. Ion-selective solid-phase electrode sensitive to ammonium ions

    International Nuclear Information System (INIS)

    Vlasov, Yu.G.; Milonova, M.S.; Antonov, P.P.; Bychkov, E.A.; Ehfa, A.Ya.

    1983-01-01

    Ammonium phosphomolybdate is investigated for the purpose of using it as membrane material of ammonium-selective solid-phase electrodes. Estimation of proton mobility and ion conductivity of ammonium phosphomolybdate is performed

  3. Solid Phase Peptide Synthesis of Antimicrobial Peptides for cell Binding Studies: Characterization Using Mass Spectrometry

    National Research Council Canada - National Science Library

    Vouros, Paul

    2002-01-01

    ...) in order to determine their anti-microbial activity. To expedite this goal, mass spectrometry was used to identify products of the solid phase synthesis and thereby optimize synthetic conditions...

  4. The Pictet-Spengler reaction in solid-phase combinatorial chemistry

    DEFF Research Database (Denmark)

    Nielsen, Thomas E; Diness, Frederik; Meldal, Morten

    2003-01-01

    The Pictet-Spengler reaction is an important reaction for the generation of tetrahydro-beta-carbolines and tetrahydroisoquinoline ring systems, which exhibit a range of biological and pharmacological properties. This review covers the solid-phase Pictet-Spengler reaction, as employed in solid...

  5. The study of actinide solubility limiting solid phases - a literature survey

    International Nuclear Information System (INIS)

    Thomason, H.P.

    1988-03-01

    It is important to identify the solid phases which control the solubilities of the actinides in a cementitious repository and to determine the effect of ageing on these solid phases. This literature survey contains information on the identification and ageing of actinide solubility limiting solid phases and includes references which do not necessarily relate to the control of solubility or the conditions found in the near-field of a repository of the methods which have been used to characterise actinide solids. The techniques most widely used are X-ray and electron diffraction, although they require a solid to be crystalline in order to identify it. As well as characterisation, diffraction patterns have been used to monitor changes in the crystallinity of a solid with time. The ageing of alpha active actinide solids involves two conflicting processes. An amorphous actinide precipitate will, like most solids, become more crystalline with time. However, the recoil energy from the alpha decay of actinides will displace some of the atoms from their lattice sites and cause a decrease in crystallinity. The crystallinity of actinide solids affects solubility and is therefore an important parameter to study. Recommendations have been made for further experimental work. (author)

  6. Resin Capsules: Permeable Containers for Parallel/Combinatorial Solid-Phase Organic Synthesis

    OpenAIRE

    Bouillon, Isabelle; Soural, Miroslav; Krchňák, Viktor

    2008-01-01

    A resin capsule is a permeable container for resin beads designed for multiple/combinatorial solid-phase organic synthesis. Resin capsules consist of a high density polyethylene ring sealed with peek mesh on both sides. The cylindrical shape of resin capsules enabled space-saving packing into plastic column-like reaction vessels commonly used for solid-phase organic synthesis. Resin capsules have been evaluated for their use in combinatorial synthesis, and a set of model compounds with excell...

  7. Facile synthesis of aliphatic isothiocyanates and thioureas on solid phase using peptide coupling reagents

    DEFF Research Database (Denmark)

    Boas, Ulrik; Andersen, Heidi Gertz; Christensen, Jørn B.

    2004-01-01

    Peptide coupling reagents can be used as versatile reagents for the formation of aliphatic isothiocyanates and thioureas on solid phase from the corresponding solid-phase anchored aliphatic primary amines. The formation of the thioureas is fast and highly chemoselective, and proceeds via formatio...... of the intermediate isothiocyanate. The isothiocyanate and subsequent thiourea formation take place under standard peptide coupling conditions using carbon disulfide as the 'amino acid'. The thioureas are released from the resin and isolated in moderate to high yields....

  8. Experimental investigation of Cs 137 distribution in a system of aquatic solution - solid phase - plant

    International Nuclear Information System (INIS)

    Marchiulioniene, D.; Kiponas, D.; Lukshiene, B.

    2005-01-01

    Investigation of Cs 137 accumulation in the plant Lepidium sativum L. (seeds, roots, aboveground part) and in the solid phase from the aquatic solution under laboratory conditions was performed. According to the obtained results, evaluation of Cs 137 distribution in the system aquatic solution - solid phase - plant and transfer of this radionuclide from the root system to the plant aboveground part during the plant growth process was done. (authors)

  9. Three magnetic particles solid phase radioimmunoassay for T4: Comparison of their results with established methods

    International Nuclear Information System (INIS)

    Bashir, T.

    1996-01-01

    The introduction of solid phase separation techniques is an important improvement in radioimmunoassays and immunoradiometric assays. Magnetic particle solid phase method has additional advantages over others, as the separation is rapid and centrifugation is not required. Three types of magnetic particles have been studied in T 4 RIA and the results have been compared with commercial kits and other established methods. (author). 4 refs, 9 figs, 2 tabs

  10. Expedient protocol for solid-phase synthesis of secondary and tertiary amines

    DEFF Research Database (Denmark)

    Olsen, Christian A; Witt, Matthias; Jaroszewski, Jerzy W

    2004-01-01

    [reaction: see text] An expedient solid-phase synthetic approach to secondary and tertiary amines was developed. The protocol employs conversion of resin-bound amino alcohols to the corresponding iodides, followed by iodide displacement with primary or secondary amines or with unprotected amino a...... alcohols. This two-step procedure, affording products in good to excellent yields, is suitable for solid-phase synthesis of polyamines....

  11. Modeling of liquid phase formation due to the solid zircaloy-4/solid stainless steel interaction

    Energy Technology Data Exchange (ETDEWEB)

    San Martin, G.E.; Piotrkowski, R. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Dept. de Combustibles Nucleares; Moyano, E. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Centro de Calculo Cientifico; Garcia, E.A. [Ente Nacional Regulador Nuclear, Buenos Aires (Argentina). Centro Atomico Ezeiza

    1995-12-31

    A diffusion model that describes the eutectic interaction between both as received and oxidized Zry-4 and AISI 316 stainless steel at temperatures between 1000 to 1300{sup 0} C is presented. The instantaneous positions of the two solid/liquid interfaces, are input data. The interdiffusion coefficients are calculated in the melt and the solid/liquid interfaces concentration values for different temperatures. (author). 7 refs., 3 figs., 1 tab.

  12. Vapour phase synthesis of salol over solid acids via transesterification

    Indian Academy of Sciences (India)

    Administrator

    salicylic acid in phenol is very low, this method requires the use of the latter in higher molar ratios. Hence, the method of transesterification of methyl salicylate with phenol is employed wherein the reac- tants, being mutually soluble in one another, can be mixed in different molar ratios. Also, the solid acid catalysts that have ...

  13. Solid-Phase Synthesis of PEGylated Lipopeptides Using Click Chemistry

    DEFF Research Database (Denmark)

    Jølck, Rasmus Irming; Berg, Rolf Henrik; Andresen, Thomas Lars

    2010-01-01

    A versatile methodology for efficient synthesis of PEGylated lipopeptides via CuAAC “Click” conjugation between alkyne-bearing solid-supported lipopeptides and azido-functionalized PEGs is described. This new and very robust method offers a unique platform for synthesizing PEGylated lipopeptides...

  14. Kinetics of solid state phase transformations: Measurement and ...

    Indian Academy of Sciences (India)

    Administrator

    in the realm of metals and alloys. While thermody- namics classifies phase changes in terms of the nature of .... structural change in uranium. 9. It is interesting to note that the temperature interval of the two phase ... diagram for the α → β transformation in uranium is shown. The dotted lines represent various heating rates,.

  15. Phase transitions of amorphous solid acetone in confined geometry investigated by reflection absorption infrared spectroscopy.

    Science.gov (United States)

    Shin, Sunghwan; Kang, Hani; Kim, Jun Soo; Kang, Heon

    2014-11-26

    We investigated the phase transformations of amorphous solid acetone under confined geometry by preparing acetone films trapped in amorphous solid water (ASW) or CCl4. Reflection absorption infrared spectroscopy (RAIRS) and temperature-programmed desorption (TPD) were used to monitor the phase changes of the acetone sample with increasing temperature. An acetone film trapped in ASW shows an abrupt change in the RAIRS features of the acetone vibrational bands during heating from 80 to 100 K, which indicates the transformation of amorphous solid acetone to a molecularly aligned crystalline phase. Further heating of the sample to 140 K produces an isotropic solid phase, and eventually a fluid phase near 157 K, at which the acetone sample is probably trapped in a pressurized, superheated condition inside the ASW matrix. Inside a CCl4 matrix, amorphous solid acetone crystallizes into a different, isotropic structure at ca. 90 K. We propose that the molecularly aligned crystalline phase formed in ASW is created by heterogeneous nucleation at the acetone-water interface, with resultant crystal growth, whereas the isotropic crystalline phase in CCl4 is formed by homogeneous crystal growth starting from the bulk region of the acetone sample.

  16. Formation of soft magnetic high entropy amorphous alloys composites containing in situ solid solution phase

    Science.gov (United States)

    Wei, Ran; Sun, Huan; Chen, Chen; Tao, Juan; Li, Fushan

    2018-03-01

    Fe-Co-Ni-Si-B high entropy amorphous alloys composites (HEAACs), which containing high entropy solid solution phase in amorphous matrix, show good soft magnetic properties and bending ductility even in optimal annealed state, were successfully developed by melt spinning method. The crystallization phase of the HEAACs is solid solution phase with body centered cubic (BCC) structure instead of brittle intermetallic phase. In addition, the BCC phase can transformed into face centered cubic (FCC) phase with temperature rise. Accordingly, Fe-Co-Ni-Si-B high entropy alloys (HEAs) with FCC structure and a small amount of BCC phase was prepared by copper mold casting method. The HEAs exhibit high yield strength (about 1200 MPa) and good plastic strain (about 18%). Meanwhile, soft magnetic characteristics of the HEAs are largely reserved from HEAACs. This work provides a new strategy to overcome the annealing induced brittleness of amorphous alloys and design new advanced materials with excellent comprehensive properties.

  17. Phase transition of solid bismuth under high pressure

    Science.gov (United States)

    Chen, Hai-Yan; Xiang, Shi-Kai; Yan, Xiao-Zhen; Zheng, Li-Rong; Zhang, Yi; Liu, Sheng-Gang; Bi, Yan

    2016-10-01

    As a widely used pressure calibrator, the structural phase transitions of bismuth from phase I, to phase II, to phase III, and then to phase V with increasing pressure at 300 K have been widely confirmed. However, there are different structural versions for phase III, most of which are determined by x-ray diffraction (XRD) technology. Using x-ray absorption fine structure (XAFS) measurements combined with ab initio calculations, we show that the proposed incommensurate composite structure of bismuth of the three configurations is the best option. An abnormal continuous increase of the nearest-neighbor distance of phase III with elevated pressure is also observed. The electronic structure transformation from semimetal to metal is responsible for the complex behavior of structure transformation. Project supported by the National Natural Science Foundation of China (Grant Nos. 10904133, 11304294, 11274281, 11404006, and U1230201), the Development Foundation of China Academy of Engineering Physics (Grant Nos. 2015B0101004, 2013B0401062, and 2012A0101001), the Research Foundation of the Laboratory of Shock Wave and Detonation, China (Grant No. 9140C670201140C67282).

  18. Solid phase transport in series fluidised bed reactors

    International Nuclear Information System (INIS)

    Hayes, M.R.

    1980-01-01

    In a multistage counter-current fluidised bed column, fluidised bed material is recycled within each stage and a fraction is continuously withdrawn to the next lower stage at a rate dependent only on the rate of removal of the fluidised bed material from the base of the column. It has a particular application to the ion exchange treatment of liquids containing suspended solids, for example leach solutions from uranium ores. (author)

  19. Improvements to solid phase phosphotriester synthesis of deoxyoligonucleotides.

    OpenAIRE

    Patel, T P; Millican, T A; Bose, C C; Titmas, R C; Mock, G A; Eaton, M A

    1982-01-01

    A solution of benzenesulphonic acid (3%, w/v) in a dimethylformamide and dichloromethane mixture (9:1, v/v) is shown to be a very effective reagent for the detritylation of deoxyoligonucleotides attached to a solid support. The levels of depurination with this reagent were lower than those observed with other reagents such as trichloroacetic acid. Coupling reactions are described using above ambient temperatures with no detectable increase in side products. Both procedures have been successfu...

  20. Torrefaction Processing for Human Solid Waste Management, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The NASA SBIR Phase I project addressed the technical feasibility of an innovative torrefaction (mild pyrolysis) processing system that can be used to sterilize...

  1. Non-collinear wave mixing for a bulk wave phase velocity measurement in an isotropic solid

    NARCIS (Netherlands)

    Demcenko, A.

    2013-01-01

    A measurement method is presented to estimate the bulk wave phase velocity in an isotropic solid when longitudinal or shear wave velocity is known. This method is based on the non-collinear plane wave interaction theory and it does not need to estimate the phase time-of-flight and wave propagation

  2. Modeling and Analysis of a Three-Phase Solid-State Var ...

    African Journals Online (AJOL)

    This paper examines the performance of a three-phase solid-state var compensator employed in the power system for reactive power compensation. The principal component of this device is a three-phase pulse-width-modulated voltage source inverter. A mathematical model of the inverter is derived and then used for the ...

  3. Stability Analysis of a Three-Phase Solid-State Var Compensator ...

    African Journals Online (AJOL)

    One of the modern devices employed in reactive power compensation is the three-phase solid-statevar compensator (SSVC). The principal component of this device is a three-phase pulse-width-modulated voltage source inverter. A mathematical model of the inverter is derived in d-q referenceframe and then used to ...

  4. Wave propagation in a condensed medium with N transforming phases: application to solid-I--solid-II-liquid bismuth

    International Nuclear Information System (INIS)

    Hayes, D.B.

    1975-01-01

    Constitutive assumptions of local thermal and pressure equilibrium in a mixture of N transforming phases allow construction of a constitutive equation of a generalized Maxwellian form suitable for studying the kinetics of phase transformations induced by shock-wave loading. This equation relates the pressure rate to the strain rate and the phase change rate, the latter being expressed as the time derivative of a vector which has components equal to the mass fractions of the constituent phases. A separate kinetic equation is required for evolution of this composition vector. Coefficients appearing in the constitutive equation depend only on properties that the mixture displays with a frozen composition which in turn depend directly on properties of the pure-phase components of the mixture. The constitutive equation is applied to solid-I--solid-II--liquid bismuth (N = 3). When wave propagation calculations on bismuth are compared with previous theory and experiments, a lower bound on the melting rate of 4 μsec -1 is found

  5. Strong Isotope Effect in Phase II of Dense Solid Hydrogen and Deuterium

    Science.gov (United States)

    Geneste, Grégory; Torrent, Marc; Bottin, François; Loubeyre, Paul

    2012-10-01

    Quantum nuclear zero-point motions in solid H2 and D2 under pressure are investigated at 80 K up to 160 GPa by first-principles path-integral molecular dynamics calculations. Molecular orientations are well defined in phase II of D2, while solid H2 exhibits large and very asymmetric angular quantum fluctuations in this phase, with possible rotation in the (bc) plane, making it difficult to associate a well-identified single classical structure. The mechanism for the transition to phase III is also described. Existing structural data support this microscopic interpretation.

  6. Practical solid and liquid phase markers for studying gastric emptying in man

    International Nuclear Information System (INIS)

    Thomforde, G.M.; Brown, M.L.; Malagelada, J.R.

    1985-01-01

    This paper presents a method used to evaluate solid and liquid phase markers for radionuclide gastric emptying studies. The authors conducted in vitro and in vivo comparative experiments employing several radiolabeled markers. Among the solid phase markers tested, Tc-99m-sulfur colloid in vivo-labeled liver and I-131-fiber performed optimally. However, Tc-99M sulfur colloid in scrambled egg showed very acceptable performance and it is significantly easier to prepare. Among liquid phase markers, they found In-111-DTPA stabilized with 1% albumin to be a good agent and appropriate for dual isotope emptying studies

  7. Solid phase extraction of actinides using graphene oxide beads

    International Nuclear Information System (INIS)

    Gujar, R.B.; Mohapatra, P.K.

    2014-01-01

    Separation of actinide ions from dilute nitric acid feed solutions is important from radioactive waste remediation point of view. A large number of separation methods are available in the literature using methods such as precipitation, ion-exchange, solvent extraction, etc. Graphene oxide (GO) are reported to be a very good sorbent for actinide ions from weakly acidic feed solutions. However, it is difficult to handle GO fine particles and any chromatographic separation is bound to be difficult as the sorbent material may be finely dispersed in the aqueous phase. It was thus thought of interest to prepare GO-based resin materials in polyether sulphone (PES) by phase inversion technique. Preparation of resins by phase inversion technique has been found to be quite efficient for metal ion separation including actinide ions. In the present work, GO based PES resin beads were prepared by phase inversion technique and the uptake of actinide and lanthanide ions. In the present work, GO based beads were prepared by phase inversion technique and the uptake of actinide and lanthanide ions (such as Am(III), Eu(III), Th(IV), Pu(IV) and U(VI)) has been studied using radiotracers

  8. Improvements to solid phase phosphotriester synthesis of deoxyoligonucleotides.

    Science.gov (United States)

    Patel, T P; Millican, T A; Bose, C C; Titmas, R C; Mock, G A; Eaton, M A

    1982-09-25

    A solution of benzenesulphonic acid (3%, w/v) in a dimethylformamide and dichloromethane mixture (9:1, v/v) is shown to be a very effective reagent for the detritylation of deoxyoligonucleotides attached to a solid support. The levels of depurination with this reagent were lower than those observed with other reagents such as trichloroacetic acid. Coupling reactions are described using above ambient temperatures with no detectable increase in side products. Both procedures have been successfully incorporated into an automated system, which can compete with the rate of synthesis by the phosphite approach.

  9. Use of solid-phase microextraction coupled to gas chromatography-mass spectrometry for determination of urinary volatile organic compounds in autistic children compared with healthy controls.

    Science.gov (United States)

    Cozzolino, Rosaria; De Magistris, Laura; Saggese, Paola; Stocchero, Matteo; Martignetti, Antonella; Di Stasio, Michele; Malorni, Antonio; Marotta, Rosa; Boscaino, Floriana; Malorni, Livia

    2014-07-01

    Autism spectrum disorders (ASDs) are a group of neurodevelopmental disorders which have a severe life-long effect on behavior and social functioning, and which are associated with metabolic abnormalities. Their diagnosis is on the basis of behavioral and developmental signs usually detected before three years of age, and there is no reliable biological marker. The objective of this study was to establish the volatile urinary metabolomic profiles of 24 autistic children and 21 healthy children (control group) to investigate volatile organic compounds (VOCs) as potential biomarkers for ASDs. Solid-phase microextraction (SPME) using DVB/CAR/PDMS sorbent coupled with gas chromatography-mass spectrometry was used to obtain the metabolomic information patterns. Urine samples were analyzed under both acid and alkaline pH, to profile a range of urinary components with different physicochemical properties. Multivariate statistics techniques were applied to bioanalytical data to visualize clusters of cases and to detect the VOCs able to differentiate autistic patients from healthy children. In particular, orthogonal projections to latent structures discriminant analysis (OPLS-DA) achieved very good separation between autistic and control groups under both acidic and alkaline pH, identifying discriminating metabolites. Among these, 3-methyl-cyclopentanone, 3-methyl-butanal, 2-methyl-butanal, and hexane under acid conditions, and 2-methyl-pyrazine, 2,3-dimethyl-pyrazine, and isoxazolo under alkaline pH had statistically higher levels in urine samples from autistic children than from the control group. Further investigation with a higher number of patients should be performed to outline the metabolic origins of these variables, define a possible association with ASDs, and verify the usefulness of these variables for early-stage diagnosis.

  10. Identification and quantification of seven volatile n-nitrosamines in cosmetics using gas chromatography/chemical ionization-mass spectrometry coupled with head space-solid phase microextraction.

    Science.gov (United States)

    Choi, Na Rae; Kim, Yong Pyo; Ji, Won Hyun; Hwang, Geum-Sook; Ahn, Yun Gyong

    2016-01-01

    An analytical method was developed for the identification and quantification of seven volatile n-nitrosamines (n-nitrosodimethylamine [NDMA], n-nitrosoethylmethylamine [NMEA], n-nitrosodiethylamine [NDEA], n-nitrosodipropylamine [NDPA], n-nitrosodibutylamine [NDBA], n-nitrosopiperidine [NPIP], and n-nitrosopyrrolidine [NPYR]) in water insoluble cream type cosmetics. It was found that the head space-solid phase microextraction (HS-SPME) was suitable for extraction, clean up, and pre-concentration of n-nitrosamines in the cream type samples so its optimal conditions were investigated. Identification and quantification of n-nitrosamines using single quadrupole gas chromatography/mass spectrometry (GC/MS) in chemical ionization (CI) mode were carried out with accurate mass measurements. Their accurate masses of protonated molecular ions were obtained within 10 mDa of the theoretical masses when sufficiently high signal was acquired from the unique calibration method using mass and isotope accuracy. For the method validation of quantification, spiking experiments were carried out to determine the linearity, recovery, and method detection limit (MDL) using three deuterated internal standards. The average recovery was 79% within 20% relative standard deviation (RSD) at the concentration of 50 ng/g. MDLs ranged from 0.46 ng/g to 36.54 ng/g, which was satisfactory for the directive limit of 50 ng/g proposed by the European Commission (EC). As a result, it was concluded that the method could be provided for the accurate mass screening, confirmation, and quantification of n-nitrosamines when applied to cosmetic inspection. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. A novel ionic liquid-modified organic-polymer monolith as the sorbent for in-tube solid-phase microextraction of acidic food additives.

    Science.gov (United States)

    Wang, Ting-Ting; Chen, Yi-Hui; Ma, Jun-Feng; Hu, Min-Jie; Li, Ying; Fang, Jiang-Hua; Gao, Hao-Qi

    2014-08-01

    A novel ionic liquid-modified organic-polymer monolithic capillary column was prepared and used for in-tube solid-phase microextraction (SPME) of acidic food additives. The primary amino group of 1-aminopropyl-3-methylimidazolium chloride was reacted with the epoxide group of glycidyl methacrylate. The as-prepared new monomer was then copolymerized in situ with acrylamide and N,N'-methylenebisacrylamide in the presence of polyethylene glycol (PEG)-8000 and PEG-10,000 as porogens. The extraction performance of the developed monolithic sorbent was evaluated for benzoic acid, 3-hydroxybenzoic acid, cinnamic acid, 2,4-dichlorophenoxyacetic acid, and 3-(trifluoromethyl)-cinnamic acid. Such a sorbent, bearing hydrophobic and anion-exchange groups, had high extraction efficiency towards the test compounds. The adsorption capacities for the analytes dissolved in water ranged from 0.18 to 1.74 μg cm(-1). Good linear calibration curves (R(2) > 0.99) were obtained, and the limits of detection (S/N = 3) for the analytes were found to be in the range 1.2-13.5 ng mL(-1). The recoveries of five acidic food additives spiked in Coca-Cola beverage samples ranged from 85.4 % to 98.3 %, with RSD less than 6.9 %. The excellent applicability of the ionic liquid (IL)-modified monolithic column was further tested by the determination of benzoic acid content in Sprite samples, further illustrating its good potential for analyzing food additives in complex samples.

  12. Crystalline-to-plastic phase transitions in molecularly thin n-dotriacontane films adsorbed on solid surfaces

    DEFF Research Database (Denmark)

    Cisternas, Edgardo; Corrales, T. P.; del Campo, V.

    2009-01-01

    Crystalline-to-rotator phase transitions have been widely studied in bulk hydrocarbons, in particular in normal alkanes. But few studies of these transitions deal with molecularly thin films of pure n-alkanes on solid substrates. In this work, we were able to grow dotriacontane (n-C32H66) films...... identify with a solid-solid phase transition. At higher coverages, we observed additional steps in the ellipsometric signal that we identify with a solid-solid phase transition in multilayer islands (similar to 333 K) and with the transition to the rotator phase in bulk crystallites (similar to 337 K...

  13. A review on solid phase extraction of actinides and lanthanides with amide based extractants.

    Science.gov (United States)

    Ansari, Seraj A; Mohapatra, Prasanta K

    2017-05-26

    Solid phase extraction is gaining attention from separation scientists due to its high chromatographic utility. Though both grafted and impregnated forms of solid phase extraction resins are popular, the later is easy to make by impregnating a given organic extractant on to an inert solid support. Solid phase extraction on an impregnated support, also known as extraction chromatography, combines the advantages of liquid-liquid extraction and the ion exchange chromatography methods. On the flip side, the impregnated extraction chromatographic resins are less stable against leaching out of the organic extractant from the pores of the support material. Grafted resins, on the other hand, have a higher stability, which allows their prolong use. The goal of this article is a brief literature review on reported actinide and lanthanide separation methods based on solid phase extractants of both the types, i.e., (i) ligand impregnation on the solid support or (ii) ligand functionalized polymers (chemically bonded resins). Though the literature survey reveals an enormous volume of studies on the extraction chromatographic separation of actinides and lanthanides using several extractants, the focus of the present article is limited to the work carried out with amide based ligands, viz. monoamides, diamides and diglycolamides. The emphasis will be on reported applied experimental results rather than on data pertaining fundamental metal complexation. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Solid phase extraction method for determination of mitragynine in ...

    African Journals Online (AJOL)

    phase high performance liquid chromatography (RP-HPLC) to determine mitragynine (MG) in rat and human urine, and to investigate the influence of caffeine (CF) on urinary excretion of MG in rats. Methods: A two-dimensional wash-elute ...

  15. A molecular dynamics calculation of solid phase of malonic acid ...

    Indian Academy of Sciences (India)

    Recent studies suggest that hydrogen bonds, in particular, hydrogen bond chains play an important role in determining the properties of a substance.We report an investigation into the triclinic phase of crystalline malonic acid. One of two intermolecular interaction potentials proposed here is seen to predict the lattice ...

  16. Kinetics of solid state phase transformations: Measurement and ...

    Indian Academy of Sciences (India)

    Administrator

    This latter quan- tity that may be obtained from equilibrium phase diagram (lever rule) or may be set as an internal ref- erence value which is obtained under very slow heating or cooling conditions. A rough estimate of τ. (assumed to be β independent in the trial estimation) can be obtained from the experimental data using.

  17. Enhanced denitrification of Pseudomonas stutzeri by a bioelectrochemical system assisted with solid-phase humin.

    Science.gov (United States)

    Xiao, Zhixing; Awata, Takanori; Zhang, Dongdong; Zhang, Chunfang; Li, Zhiling; Katayama, Arata

    2016-07-01

    The denitrification reactions performed by Pseudomonas stutzeri JCM20778 were enhanced electrochemically with the use of solid-phase humin, although P. stutzeri itself was incapable of receiving electrons directly from the graphite electrode. Electrochemically reduced humin enhanced the microbial, but not abiotic, denitrification reactions. Electric current and cyclic voltammetry analyses suggested that the solid-phase humin functioned as an electron donor for the denitrification reactions of P. stutzeri. Nitrogen balance study and the estimation of the first-order rate constants of the consecutive denitrification reactions suggested that the solid-phase humin enhanced all reducing reactions from nitrate to nitrogen gas. Considering the wide distribution of humin in the environment, the findings that solid-phase humin can assist in electron transfer, from the electrode to a denitrifying bacterium that has little ability to directly utilize external electrons, has important implications for the widespread application of bioelectrochemical systems assisted by solid-phase humin for enhancing microbial denitrification. Copyright © 2015 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  18. Solid-state phase equilibria in the Fe-Pt-Pr ternary system at 1173 K

    International Nuclear Information System (INIS)

    Ren Jing; Gu Zhengfei; Cheng Gang; Zhou Huaiying

    2005-01-01

    The solid-state phase equilibria in the Fe-Pt-Pr ternary system at 1173 K (Pr ≤ 70%) were investigated by X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersion spectroscopy (EDS) techniques. The 1173 K isothermal section consists of 13 single-phase regions, 22 two-phase regions and 10 three-phase regions. At 1173 K, we have observed that the maximum solid solubility of Pt in α-Fe is below 1.5 at.% and the solid solution region of Pt in γ-Fe is from 2 to 35 at.%; the maximum solid solubility of Fe in Pt is 18 at.%. The maximum solubility of Fe in PrPt 5 , PrPt 3 , PrPt 2 , Pr 3 Pt 4 , PrPt, Pr 3 Pt 2 and Pr 7 Pt 3 is below 1 at.%. The maximum solubility of Pr in α-(Fe, Pt), γ-(Fe, Pt), FePt, FePt 3 and (Pt, Fe) (the solid solution of Fe in Pt) is 6, 2, 4, 4.5 and 1.5 at.%, respectively. In this work, it is found that the phase Pr 3 Pt 4 does not exist in the ternary system. The binary compounds Fe 7 Pr and Fe 2 Pr and any new ternary compounds were not observed

  19. Solid State KA-Band, Solid State W-Band and TWT Amplifiers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Phase I of the proposal describes plans to develop a state of the art transmitter for the W-Band and KA -Band Cloud Radar system. Our focus will be concentrated in...

  20. The synthesis and properties of the phases obtained by solid-solid reactions

    Directory of Open Access Journals (Sweden)

    Blonska-Tabero A.

    2008-01-01

    Full Text Available The presented work encompasses the subject of the studies and the results obtained over the last years by the research workers of the Department of Inorganic Chemistry. They include mainly the studies on the reactivity of metal oxides, searching for new phases in binary and ternary systems of metal oxides as well as describing phase relations establishing in such systems. They also encompass works on the extensive characteristics of physico-chemical properties of the newly obtained compounds.