  1. Enteroelysis and spiral CT examination in diagnosis and evaluation of small bowel Crohn's disease

    International Nuclear Information System (INIS)

    Mako, E.K.; Mester, A.R.; Tarjan, Zs.; Karlinger, K.; Toth, G.

    2000-01-01

    Introduction: During the last few decades introducing many of new radiologic methods, diagnostic conditions and facilities of Crohn's disease has became markedly improved. Appropriate using of these techniques definitely modifies the management of patients with known or suspected Crohn's disease serving reliable information about extent, severity and possible complications of disease. Enteroclysis and Computed tomography are the two major and basic methods to disclose or confirm diagnosis of Crohn's disease, obtain appropriate inforination about disease either with mucosal, transmural or extraintestinal manifestation. Methods and patients: We evaluated 281 patients who were referred in our institution under suspicion of Crohn's disease. Enteroclysis and abdominal spiral CT in all cases were carried out usually within 1 week. The 172 patients underwent abdominal spiral CT as the primary examination to evaluate diagnostic value of spiral CT in this entity, while 109 patients had enteroclysis followed by abdominal CT. In 11 cases we also perforined CT enteroclysis with administration of 0.5% methylcellulose solution thorough nasojejunal tube controlled by electric motor driven contrast pump. Results were compared with final clinical, pathological or surgical data were available. Results: From the 281 patients eventually 74 proved Crohn's disease; sensitivity and specificity of enteroclysis proved to be 96 and 98%, while spiral CT sensitivity and specificity was 94 and 95%, respectively. Enteroclysis was superior to the spiral CT in demonstration of early lesions and functional disorders, while spiral CT proved to be essential in evaluation of transmural and extraintestinal complications. Conclusions: Regarding enteroclysis and spiral CT as complementary methods, they provide excellent results in diagnosis of Crohn's disease

  2. [Effective dose in X-ray examinations: comparison between spiral CT and urography in the study of renal colic].

    Science.gov (United States)

    De Denaro, M; Bregant, P; Cupardo, F; De Guarrini, F; Rimondini, A; Pozzi Mucelli, R

    2001-10-01

    The aim of this study was to calculate the effective dose in patients with renal colic undergoing spiral CT examination and IVU examination, and to verify the ability of the systems to measure the effective dose. Dose measurements were carried out for both diagnostic techniques by employing an anthropomorphic phantom with thermoluminescence detectors (TLDs) fitted inside the phantom. The data so obtained were compared with dose estimations based on published tables, which allow to obtain the effective dose on the basis of the experimental value of common dose indicators, the performance of the equipment and the setting of the acquisition parameters for such examinations. The absorbed dose inside the phantom had an homogeneous distribution during the spiral CT examination, while during the IVU there were significant differences in the absorbed dose between different zones of the body, due to the geometry of the x-ray beam. The mean effective dose, which corresponds to the average of values absorbed by males and females, measured by TLD dosimeters for spiral CT examination was 3.3 time that for IVU. For both spiral CT and IVU the dose to the male was significantly lower than that to the female, owing to the anatomic position of female gonads that are completely exposed to the x-ray radiations during the study, while male gonads lie outside of the exposed area. Both methods for estimating the effective dose in spiral CT, based on CTDI value, significantly underestimated the value derived from experimental TLDs measurement. The evaluation of effective dose in IVU, based on the measurement of the skin dose in air, overestimated the measurement performed by TLDs. Dose measurement performed by TLD dosimeters fitted inside an anthropomorphic phantom has the advantage of calculating experimentally the absorbed dose in different anatomic districts. However, the method is quite difficult, and introduces some imprecisions due to the simplified morphology of the phantom and the

  3. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Baum, Ulrich E-mail: baum@idr.med.uni-erlangen.de; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-03-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  4. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  5. To evaluate vascular complications of transplant kidney examined by multislice spiral CT angiograph

    International Nuclear Information System (INIS)

    Peng Qian; Fan Miao; Luo Xiaomei

    2008-01-01

    Objective: To evaluate the value of multislice CT angiography (MSCTA) in vascular complications of transplant kidney. Methods: Six transplant kidneys were undergone enhanced MSCT scanning postoperation. MPR, CPR, VR and VP reformation were performed to observe transplant kidney's parenchyma, renal artery, and renal vein. To analysis all the reconstruction technique and find the advantage and shortage of them. Results: One case showed enhanced function of transplant kidney decreased. Vascular stenosis was found in one case and false aneurysm was found in another transplant kidney. Transplant kidney were enhanced normal in the left three cases. MPR couldn't reconstruct all the tortuous vessel of renal hilus in one plane. But all six cases could expose the vessel of renal hilus very clearly in coronal section and sagittal plane of CPR. Six cases of VR could observe the vessel direction and lesions outside vessel through rotate the reconstruction image. VP could see through inside the vessel of transplant kidney. Conclusion: MSCTA has an important role as an imaging technique to evaluate vascular complications of transplant kidney, it can replace DSA. (authors)

  6. Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography

    International Nuclear Information System (INIS)

    Villari, N.; Stecco, A.; Zatelli, G.

    1999-01-01

    The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations [it

  7. Lung studies with spiral CT. pitch 1 versus pitch 2

    International Nuclear Information System (INIS)

    Sartoni Galloni, S.; Miceli, M.; Lipparino, M.; Burzi, M.; Gigli, F.; Rossi, M.S.; Santoli, G.; Guidarelli, G.

    1999-01-01

    In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality [it

  8. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  9. Spiral CT for cervical lymph node enlargement. Early clinical results

    International Nuclear Information System (INIS)

    Steinkamp, H.J.; Keske, U.; Schedel, J.; Hosten, N.; Felix, R.

    1994-01-01

    Spiral CT was performed before treatment in 35 patients with suspected cervical lymph node enlargement. By coronary and sagittal reconstruction it is possible to utilise the M/Q quotient which has become accepted as the result of sonographic and MRI examinations. It is now possible to obtain high diagnostic accuracy (97%) for distinguishing between reactive change from metastatic infiltration of lymph nodes (>8 mm) by using CT. Using spiral CT with 5 mm table movement, three patients diagnosed as stage N1 by axial CT were shown to be N2b. This represents a highly sensitive and highly specific method of lymph node diagnosis. Further diagnostic improvement derives from the ability to relate the lymph nodes to surrounding tissues. Spiral CT is also suitable for defining other space occupying lesions, e.g., the exact extent of retropharyngeal abscesses, abnormalities of the salivary glands or laryngocoeles. (orig.)

  10. Virtual bronchoscopy based on spiral CT images

    Science.gov (United States)

    Englmeier, Karl-Hans; Haubner, Michael; Krapichler, Christian; Schuhmann, Dietrich; Seemann, Mark; Fuerst, H.; Reiser, Maximilian

    1998-06-01

    Purpose: To improve the diagnosis of pathologic modified airways, a visualization system has been developed and tested based on the techniques of digital image analysis, synthesis of spiral CT and the visualization by methods of virtual reality. Materials and Methods: 20 patients with pathologic modifications of the airways (tumors, obstructions) were examined with Spiral-CT. The three-dimensional shape of the airways and the lung tissue is defined by a semiautomatic volume growing method and a following geometric surface reconstruction. This is the basis of a multidimensional display system which visualizes volumes, surfaces and computation results simultaneously. To enable the intuitive and immersive inspection of the airways a virtual reality system, consisting of two graphic engines, a head mounted display system, data gloves and specialized software was integrated. Results: In 20 cases the extension of the pathologic modification of the airways could be visualized with the virtual bronchoscopy. The user interacts with and manipulates the 3D model of the airways in an intuitive and immersive way. In contrast to previously proposed virtual bronchoscopy systems the described method permits truly interactive navigation and detailed exploration of anatomic structures. The system enables a user oriented and fast inspection of the volumetric image data. Conclusion: To support radiological diagnosis with additional information in an easy to use and fast way a virtual bronchoscopy system was developed. It enables the immersive and intuitive interaction with 3D Spiral CTs by truly 3D navigation within the airway system. The complex anatomy of the central tracheobronchial system could be clearly visualized. Peripheral bronchi are displayed up to 5th degree.

  11. Dynamic study of the larynx with spiral CT

    International Nuclear Information System (INIS)

    Park, Jong Yeon; Choi, Chang Ho; Yoon, Chi Soon; Kim, Yoon Gyoo; Nam, Sang Hwa; Kim, Kun Il; Kim, Byung Soo; Wang, Soo Guen

    1994-01-01

    It is essential to know the functional and morphologic changes of the larynx in the evaluation of laryngeal lesions. Conventional CT which has relatively long examination time is not suitable for this aim. The purposes of this study are to evaluate the capability of spiral CT in the dynamic study of the larynx and to know whether this new technique can replace conventional laryngography or not. Five healthy volunteers and 20 patients with laryngeal lesions underwent spiral dynamic CT scans with 3-dimensional reconstruction of the mucosal surface. A series of spiral CT scans were done while the volunteers performed various laryngeal positions to obtain the functional and morphologic information. The maneuvers used were: quite breathing, 'E' phonation, Valsalva maneuver, modified Valsalva maneuver, and a new method of our own, 'modified breath holding' technique. The patients were scanned when in quite breathing. Additional scans were obtained by using the 'modified breath holding' technique. The dynamic study with spiral CT could provide high resolutional images which nicely depicted the mobility of vocal cords and the mucosal changes of the laryngeal cavity in both healthy volunteer and patient groups. In patient group, the new 'modified breath holding' technique was easier and more reproducible than other maneuvers. Spiral CT allows a dynamic study of the larynx and can be a new alternative of laryngography

  12. Spiral CT manifestations of spherical pneumonia

    International Nuclear Information System (INIS)

    Li Xiaohong; Yang Hongwei; Xu Chunmin; Qin Xiu

    2008-01-01

    Objective: To explore the Spiral CT manifestations and differential diagnosis of spherical pneumonia. Methods: 18 cases of spherical pneumonia and 20 cases of peripheral pulmonary carcinoma were selected, both of them were confirmed by clinic and/or pathology. The SCT findings of both groups were compared retrospectively. Results: Main spiral CT findings of spherical pneumonia were showed as followings: square or triangular lesions adjacent to pleura; with irregular shape, blurry, slightly lobulated margin, sometimes with halo sign. Small inflammatory patches and intensified vascular markings around the lesions were seen. Lesions became smaller or vanished after short-term anti-inflammatory treatment. Conclusion: Spherical pneumonia showed some characteristics on Spiral CT scan, which are helpful in diagnosis and differential diagnosis of this disease. (authors)

  13. Initial clinical experience with spiral CT angiography in the abdomen

    International Nuclear Information System (INIS)

    Gaa, J.; Stehling, M.K.; Costello, P.

    1993-01-01

    The latest developments in modern CT instruments, offering scanning times of a second, opened up new possibilities in CT imaging in combination with the spiral technique. The data set normally taken with single-breath-hold technique is free of respiratory artefacts and thus is a good basis for accurate 3D image reconstruction. Spiral CTA allows a non-invasive 3D imaging of various blood vessels. Patients with abdominal aortic aneurysms of aorto-iliac bypass can be examined as outpatients within 15 minutes. (orig.) [de

  14. Multislice spiral CT of the paranasal sinuses; Mehrschicht-Spiral-CT der Nasennebenhoehlen: Erste Erfahrungen unter besonderer Beruecksichtigung der Strahlenexposition

    Energy Technology Data Exchange (ETDEWEB)

    Dammann, F.; Bode, A.; Heuschmid, M.; Kopp, A.; Georg, C.; Pereira, P.L.; Claussen, C.D. [Tuebingen Univ. (Germany). Radiologische Universitaetsklinik

    2000-08-01

    Purpose: To evaluate the potential of multislice CT in the diagnosis of the paranasal sinuses. Methods: Dose measurements were performed exposing an Alderson Rando phantom in a four-slice spiral CT (MS-CT) while applying a variety of scan parameters. Additionally, 30 consecutive patients underwent a transversal examination by the MS-CT using 1/1/3.5/0.5 mm spiral parameters and an additional transversal or coronal scan on a conventional single slice spiral CT (SS-CT) with 2/3/1 mm. Coronal reformations of the MS-CT were compared with the primary coronal SS-CT, or coronal reformations of the transversal SS-CT, respectively, with regard to image quality and depiction of relevant anatomical details of the region. Results: Superficial exposure values at the level of the eye lenses as well as for the thyroid gland were superior for MS-CT (3.62 mGy, and 0.12 mGy, resp.) as compared to SS-CT (2.96 mGy, and 0.07 mGy). Image quality was equal or superior for MS-CT as compared to SS-CT in all but one case. Drawbacks of SS-CT, such as dental amalgam artifacts, stair step artifacts or partial volume artifacts did not notably affect the coronal reformations of MS-CT. Conclusions: MS-CT seems to have the potential to replace primary coronal CT of the paranasal sinuses without any loss of image quality, but may even improve the overall diagnostic value. Radiation doses may still have to be reduced. (orig.) [German] Ziel: Erprobung eines Multislice-CT (MS-CT) zur Diagnostik der Nasennebenhoehlen (NNH). Methode: An einem Alderson Rando Phantom wurden Dosismessungen bei der Spiral-CT der NNH mit einem Mehrschicht-CT (MS-CT) unter Verwendung unterschiedlicher Scanparameter durchgefuehrt. Anschliessend wurden 30 konsekutive Patienten an dem MS-CT mit den Spiralparametern 1/1/3,5/0,5 mm und einem konventionellen Einzeilen Spiral-CT (SS-CT; 2/3/1 mm) untersucht. Die koronaren Rekonstruktionen der transversalen MS-CT wurden mit den koronaren Rekonstruktionen bzw. den primaeren koronaren

  15. Diagnosis of pulmonary embolism with spiral and electron-beam CT; Diagnostik der Lungenembolie mit Spiral- und Elektronenstrahl-CT

    Energy Technology Data Exchange (ETDEWEB)

    Schoepf, U.J.; Bruening, R.D.; Becker, C.R.; Konschitzky, H.; Muehling, O.; Staebler, A.; Helmberger, T.; Holzknecht, N.; Reiser, M.F. [Muenchen Univ. (Germany). Inst. fuer Radiologische Diagnostik; Knez, A.; Haberl, R. [Muenchen Univ. (Germany). Medizinische Klinik 1

    1998-12-01

    Purpose: To compare spiral (SCT) and electron-beam CT (EBT) for the diagnosis of pulmonary embolism (PE). Materials and methods: From June 1997 to June 1998 188 patients with suspected acute or chronic thrombembolism of the pulmonary arteries were examined. A total of 108 patients were scanned using SCT and 80 patients using EBT. On each scanner two different scan protocols were evaluated. Conclusions: Advanced CT scanning techniques allow the highly accurate diagnosis of central and peripheral PE. Other potentially life-threatening underlying diseases are also readily recognized. (orig./AJ) [Deutsch] Fragestellung: Spiral-CT (SCT) und Elektronenstrahlcomputertomographie (EBT) sollten hinsichtlich ihrer Eignung fuer die Diagnostik der Lungenembolie (LE) verglichen werden. Methode: Von Juni 1997 bis Juni 1998 wurden 188 Patienten mit Verdacht auf akute oder chronische thrombembolische Veraenderungen der Lungenarterien untersucht. Die CT-Diagnostik erfolgte dabei bei 108 Patienten mit Spiral-CT und bei 80 Patienten mit EBT. Schlussfolgerungen: Moderne CT-Scan-Verfahren erlauben mit hoher Genauigkeit die Diagnose der zentralen und peripheren Lungenembolie. Die EBT bietet Vorteile in der Darstellung herznaher peripherer Lungenarterien. Andere lebendsbedrohliche Ursachen fuer die Beschwerden des Patienten werden mit der CT sicher erkannt. (orig./AJ)

  16. Spiral CT angiography of the abdominal aorta and its branches

    Energy Technology Data Exchange (ETDEWEB)

    Costello, P. [Dept. of Radiology, Deaconess Hospital and Harvard Medical School, Boston, MA (United States); Gaa, J. [Dept. of Radiology, Deaconess Hospital and Harvard Medical School, Boston, MA (United States)

    1993-08-01

    Spiral CT angiography (CTA) was performed on 19 patients for the pre-operative assessment of abdominal aortic aneurysms and in 3 post-operative renal artery bypass patients. Spiral CTA performed during intravenous contrast infusion provided a volume of data that was reconstructed at thin increments. Images were edited and reformatted either as surface rendered three-dimensional or maximum intensity projection (MIP) displays. Final images were viewed in a cine-loop presentation of quality comparable to conventional angiograms. The entire aorta can be examined from the coeliac axis to mid-pelvis with only 107 ml of 60% contrast. (orig.)

  17. Pulmonary embolism: spiral CT evaluation; Embolie pulmonaire: apport de la tomodensitometrie helicoidale

    Energy Technology Data Exchange (ETDEWEB)

    Senac, J.P.; Vernhet, H.; Bousquet, C.; Giron, J.; Pieuchot, P.; Durand, G.; Benezet, O.; Aubas, P. [Centre Hospitalier Universitaire, 34 - Montpellier (France)

    1995-06-01

    Purpose: Spiral computed tomography was compared retrospectively with digital substraction pulmonary angiography (PA) in 45 patients suspected of having acute or chronic pulmonary embolism. Materials and method : 45 patients in whom the presence of acute or chronic pulmonary embolism was suspected underwent examination by spiral CT and PA. Diagnosis of pulmonary embolism was based on the direct visualization of intraluminal clots. The study of the agreement between the two methods was based on the Kappa test. In 35 cases, pulmonary emboli were proved. Acute pulmonary emboli were present in 28 cases and chronic in 7 cases. Results: Spiral computed tomography represents an excellent way to detect acute pulmonary embolism. In the chronic form, spiral CT is better than PA to detect intraluminal clots. However, Spiral CT can fail to detect small emboli in the peripheral arterial bed. In the 10 patients without pulmonary embolism, the spiral CT proved diagnosis pulmonary oedema (n=3), lymphangi-carcinoma (n=4), pleural effusion (n=3). Conclusion: This study suggest that the spiral CT examination is accurate for diagnosis of pulmonary embolism specifically in case of suspected important embolism. The advantages of spiral CT are multiple (non invasive, wide diagnosis spectrum). However, may be a limitation to is use is insufficient distal thrombi detection. This eventuality (5 to 10% in the Pioped study) justify the practice of pulmonary angiography. Spiral CT improvements should reduce this insufficiency in the next future. (Authors). 16 refs., 4 figs., 3 tabs.

  18. Three-dimensional spiral CT for neurosurgical planning

    International Nuclear Information System (INIS)

    Klein, H.M.; Bertalanffy, H.; Mayfrank, L.; Thron, A.; Guenther, R.W.; Gilsbach, J.M.

    1994-01-01

    We carried out 22 examinations to determine the value of three-dimensional (3D) volumetric CT (spiral CT) for planning neurosurgical procedures. All examinations were carried out on a of the first generation spiral CT. A tube model was used to investigate the influence of different parameter settings. Bolus injection of nonionic contrast medium was used when vessels or strongly enhancing tumours were to be delineated. 3D reconstructions were carried out using the integrated 3D software of the scanner. We found a table feed of 3 mm/s with a slice thickness of 2 mm and an increment of 1 mm to be suitable for most purposes. For larger regions of interest a table feed of 5 mm was the maximum which could be used without blurring of the 3D images. Particular advantages of 3D reconstructed spiral scanning were seen in the planning of approaches to the lower clivus, acquired or congenital bony abnormalities and when the relationship between vessels, tumour and bone was important. (orig.)

  19. Pancreatic adenocarcinoma : usefulness of two and three phase spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyeong Ah; Kim, Hyung Soo; Park, Cheol Min; Cha, In Ho [Korea Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-10-01

    To evaluate the efficacy of each phases in two and three phase spiral CT in the detection of pancreatic adenocarcinoma. Two phase spiral CT images of 18 patients and three phase spiral CT images of 12 patients with pathologically-proven pancreatic ductal adenocarcinoma were retrospectively compared. Using a single spiral scan, images of early and delayed phases were obtained at 43 seconds and 2{approx}3minutes respectively initiating the after administration of 100-120cc of contrast material (2{approx}3cc/sec), Images of arterial, portal and delayed phases were also obtained at 25 and 60 seconds, and 3{approx}4minutes, respectively, by the use of a double spiral scan. CT scans were performed with 10mm collimation at 1:1 pitch table speed. Contrast between the tumor and adjacent pancreatic parenchyma were compared and graded and enhancement pattern of the tumor were analysed together. In 12 patients (66.7%), images of the early phase were superior to those of the delayed phase. images of the portal phase were superior to those of the arterial phase. Enhancement of tumor was seen in four patients;all tumors were less than 3cm in size. The early phase of two phase spiral CT is superior to the delayed phase and the portal phase of three phase spiral CT is superior to the arterial phase. Both arterial and portal phases are superior to the delayed phase.

  20. Spiral CT colonography in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Tarjan, Zsolt; Zagoni, Tamas; Gyoerke, Tamas; Mester, Adam; Karlinger, Kinga; Mako, Erno K.

    2000-01-01

    Objective: Most of the studies on virtual colonoscopy are dealing with the role of detecting colorectal polyps or neoplasms. We have undertaken this study to evaluate the value of CT colonography in patients with colonic Crohn's disease. Methods and material: Five patients (three males, two females, 23-51 years, mean age 42 years) with known (4) or suspected (1) Crohn's disease of the colon underwent fiberoptic colonoscopy and CT colonography in the same day or during a 1-week period. The images were evaluated with the so called zoomed axial slice movie technique and in some regions intra- and extraluminal surface shaded and volume rendered images were generated on a separate workstation. The results were compared to those of a colonoscopy. Results: The final diagnosis was Crohn's disease in four patients and colitis ulcerosa in one. Total examination was possible by colonoscopy in two cases, and with CT colonography in all five cases. The wall of those segments severely affected by the disease were depicted by the axial CT scans to be thickened. The thick walled, segments with narrow lumen seen on CT colonography corresponded to the regions where colonoscopy was failed to pass. Air filled sinus tracts, thickening of the wall of the terminal ileum, loss of haustration pseudopolyps and deep ulcers were seen in CT colonography. Three dimensional (3D) endoluminal views demonstrated pseudopolyps similar to endoscopic images None of the colonoscopically reported shallow ulcerations or aphtoid ulcerations or granular mucosal surface were observed on 2- or 3D CT colonographic images. Conclusion: CT colonography by depicting colonic wall thickening seems to be a useful tool in the diagnosis of Crohn's colitis, which could be a single examination depicting the intraluminal, and transmural extent of the disease

  1. Three-dimensional dental imaging by spiral CT

    Science.gov (United States)

    Vannier, Michael W.; Hildebolt, Charles F.; Conover, Gary; Knapp, Robert H.; Yokoyama-Crothers, Naoko; Wang, Ge

    1995-05-01

    Three-dimensional image acquisition, display, and analysis of dental structures was performed and validated using spiral computed tomography (SCT) with metal artifact suppression. Isolated extracted teeth, a dry mandible, cadaver mandible, and cadaver head were scanned and reconstructed using a spiral CT scanner (Siemens Somatom PLUS-S) with 1 mm detector collimation, 1-mm table feed, and 0.1 - 1 mm reconstruction interval using specially developed software. Algorithms for metal artifact reduction including extended attenuation range and interpolation of missing projections were applied. Volumetric rendering of voxel sum images was performed to synthesize images comparable to conventional intraoral dental radiographs. Direct comparison of voxel-based synthetic and digitized film images was made. Several isolated, extracted teeth were sectioned with a diamond saw and submitted for histomorphometric analysis to aid in direct comparison with CT slice images obtained by multiplanar reconstruction. Metal artifact reduction was successful in markedly reducing the streaks and star patterns that usually accompany metallic restorations and intraoral appliances. Individual teeth were comparable to CT slice images. Voxel sum images were comparable to dental radiographs; however, for the SCT images, the spatial resolution was higher within the plane of section than it was orthogonal to the plane of section. Serial examinations were obtained by SCT, registered by surface matching, and interval change measured by 3D subtraction. Simulated lesions and restorations were introduced and quantitatively evaluated pre- and post-interventionally to assess imaging method performance.

  2. The value of spiral CT scan on fracture of ankle joint and tarsal bones

    International Nuclear Information System (INIS)

    Li Zhaoli; Liang Jingyin; Pan Zhifeng

    2009-01-01

    Objective: To study the value of spiral CT scan on the fracture of ankle joint and tarsal bones. Methods: 43 cases with the fracture of ankle joint and tarsal bones were collected and analyzed. All the cases were examined by plain film radiography and spiral CT thin slice scan. Multi-planar reformation (MPR), surface shaded display (SSD) and other techniques of image post-processing were performed in 35 cases of them. Results: Spiral CT scan could demonstrate more fractures than plain film radiography in 28 cases(65.1%). There are 15 cases (34.9%) which are normal in plain film radiography but abnormal in Spiral CT scan. Spiral CT could demonstrate the different length, width, direction and number of linear low density shadow. SSD and MPR were performed again in the cases with avulsion fracture and fragmental fracture to demonstrate the fracture direction and the shape, size and location of fragments more clearly. Conclusion: Spiral CT thin slice scan with image post-processing techniques can play an important role in fracture of ankle joint and tarsal bones. (authors)

  3. Spiral CT pneumocolon: applications, status and limitations

    International Nuclear Information System (INIS)

    Harvey, C.J.; Renfrew, I.; Taylor, S.; Gillams, A.R.; Lees, W.R.

    2001-01-01

    CT pneumocolon is a promising new technique in the diagnosis and management of colon pathology. CT pneumocolon can detect (sensitivity >95%) and stage (accuracy 79%) colorectal cancer and is very accurate in the differentiation of malignant from benign colonic pathologies. It has excellent detection rates for polyps >10 mm in diameter. Several studies using 3D virtual colonoscopy have already proven its high sensitivity and specificity in polyp detection making this technique robust as a screening tool. The combined results for virtual colonoscopy, from all centres, show a sensitivity of >85% in the detection of polyps 10 mm or greater in size, 70-80% for 5-9 mm polyps and an overall specificity of 90%. CT pneumocolon is a safe, non-invasive and cost-effective method for detecting colonic carcinomas and adenomas and correctly identifying which patients need further colonoscopy. The technique is quick, well tolerated and non-operator dependent. It can also image the proximal colon when distal stenoses prevent endoscopic and barium examination. CT pneumocolon is able to identify the features and complications of inflammatory bowel disease. Further research is warranted to fully assess its impact in terms of a screening tool, acceptability, availability and cost benefit. (orig.)

  4. Multi-slice spiral CT diagnosis of carotid body tumor

    International Nuclear Information System (INIS)

    Li Peiling; Leng Renli; Li Shu; Xie Xiuli; Xu Ke

    2006-01-01

    Objective: to explore the Multi-slice spiral CT (MSCT) findings of carotid body tumor (CBT). Methods: Twelve cases of CBT proved by surgery were collected in this study and all patients accepted contrast-enhanced MSCT examination. Two-dimensional and three-dimensional post-processing were performed at diagnostic workstation using Aquilion 1.42. The CT features of CBT were analyzed. Results Each of 12 patients had one lesion. All lesions demonstrated well-marginated masses of homogeneous soft- tissue density with CT value within 29-48 HU on pre-enhanced images. All lesions were markedly enhanced with CT value over 200 HU on arterial-phase images, and the density of lesions decreased rapidly on delay- phase images. Twelve lesions were all located at the level of carotid artery bifurcation, 3 of them enveloping common carotid artery and internal/external carotid artery, and other 9 of them riding right on the carotid bifurcation. Internal carotid artery usually were shifted toward posterior-lateral, and external carotid artery toward anterior or anterior-medial. Conclusion: Contrast-enhanced MSCT examination not only can make a qualitative diagnosis of CBT, but determine its accurate location. It plays an importantly instructional role in clinical diagnosis and treatment. (authors)

  5. Multidetector spiral CT arthrography of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Lecouvet, Frederic E. [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)], E-mail: frederic.lecouvet@uclouvain.be; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)

    2008-10-15

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings.

  6. Multidetector spiral CT arthrography of the shoulder

    International Nuclear Information System (INIS)

    Lecouvet, Frederic E.; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile

    2008-01-01

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings

  7. Abdominal wall hernias: imaging with spiral CT

    International Nuclear Information System (INIS)

    Stabile Ianora, A.A.; Midiri, M.; Vinci, R.; Rotondo, A.; Angelelli, G.

    2000-01-01

    Computed tomography is an accurate method of identifying the various types of abdominal wall hernias, especially if they are clinically occult, and of distinguishing them from other diseases such as hematomas, abscesses and neoplasia. In this study we examined the CT images of 94 patients affected by abdominal wall hernias observed over a period of 6 years. Computed tomography clearly demonstrates the anatomical site of the hernial sac, the content and any occlusive bowel complications due to incarceration or strangulation. Clinical diagnosis of external hernias is particularly difficult in obese patients or in those with laparotic scars. In these cases abdominal imaging is essential for a correct preoperative diagnosis and to determine the most effective treatment. (orig.)

  8. Evaluation of spiral CT in the diagnosis of ureteral diseases

    International Nuclear Information System (INIS)

    Li Jiansheng; Li Kangyin; Chen Huyi; Qiang Haixia; Shen Guoqiang; Li Jing

    2001-01-01

    Objective: To discuss the diagnostic value of spiral CT in ureteral diseases. Methods: Spiral CT urography (SCTU) was performed in 27 cases with ureteral diseases, including 9 cases of ureteral calculus, 5 carcinomas, 9 stenosis, 1 malformation, 1 inflammation and 2 fistula. Of the 27 cases,15 also underwent non-enhanced spiral CT scan and 10 received intravenous urography(IVU). Results: (1) Eight cases of radiolucent ureteral calculus were clearly showed by non-enhanced spiral CT. (2) On SCTU, the location and diameter of 9 ureteral calculus (8 radiolucent, 1 radiopaque) and enlargement of renal pelvis and ureter were displayed. Irregular ureteral wall, local rarefaction or obstruction of contrast medium in ureter were detected in 5 case of tumor. Ureteral lumen was narrowed gradually in 7 cases of simple ureteral stenosis without thickening of the wall. Two cases with ectopic vessel compression were clarified at the boundary of ureter and pelvis. 1 malformation with double renal pelvis and ureter was demonstrated. The location and direction of ureteral fistula were notified. Conclusion: SCTU is superior to IVU and conventional CT in improving diagnostic accuracy of ureteral disease

  9. Renal colic: comparison of spiral CT, US and IVU in the detection of ureteral calculi.

    Science.gov (United States)

    Yilmaz, S; Sindel, T; Arslan, G; Ozkaynak, C; Karaali, K; Kabaalioğlu, A; Lüleci, E

    1998-01-01

    The aim of our study was to compare non-contrast spiral CT, US and intravenous urography (IVU) in the evaluation of patients with renal colic for the diagnosis of ureteral calculi. During a period of 17 months, 112 patients with renal colic were examined with spiral CT, US and IVU. Fifteen patients were lost to follow-up and excluded. The remaining 97 patients were defined to be either true positive or negative for ureterolithiasis based on the follow-up data. Sensitivity, specificity, positive and negative predictive value and accuracy of spiral CT, US and IVU were determined, and secondary signs of ureteral stones and other pathologies causing renal colic detected with these modalities were noted. Of 97 patients, 64 were confirmed to have ureteral calculi based on stone recovery or urological interventions. Thirty-three patients were proved not to have ureteral calculi based on failure to recover a stone and diagnoses unrelated to ureterolithiasis. Spiral CT was found to be the best modality for depicting ureteral stones with a sensitivity of 94 % and a specificity of 97 %. For US and IVU, these figures were 19, 97, 52, and 94 %, respectively. Spiral CT is superior to US and IVU in the demonstration of ureteral calculi in patients with renal colic, but because of its high cost, higher radiation dose and high workload, it should be reserved for cases where US and IVU do not show the cause of symptoms.

  10. Hepatic spiral CT in children: scan delay time-enhancement analysis

    International Nuclear Information System (INIS)

    Luker, G.D.; Siegel, M.J.; Bradley, D.A.; Baty, J.D.

    1996-01-01

    Purpose. To compare the effect of different time delays between contrast administration and the start of spiral CT scanning on hepatic enhancement in children. Materials and methods. Forty-five children (2-9 years old, mean 6 years) with no evidence of hepatic disease were examined with spiral CT. Sequential spiral scans through the entire liver were performed following a uniphasic injection of nonionic contrast medium. In group 1 scanning started at 80 % of the contrast injection time, in group 2 scanning started at 100 % of injection time, and in group 3 scanning started at 150 % of injection time. Mean hepatic, aortic, and inferior vena caval enhancement were determined using regions-of-interest measurements. Results. Mean hepatic enhancement was 41.4, 47.0, and 40.6 HU for the 80 %, 100 %, and 150 % injection times, respectively. Enhancement was significantly greater in the 100 % injection time group (p < 0.05). A mean aortocaval difference of greater than 10 HU was present in all examinations. Conclusion. Our results suggest that delaying the initiation of spiral CT scanning until the completion of the contrast injection increases hepatic enhancement in children. These data should help to improve the quality of hepatic spiral CT in pediatric patients. (orig.). With 2 tabs

  11. Helical CT defecography; La defecografia con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M. [Genua Univ., Genua (Italy). Ist. di Radiologia, Cattedra R; Tornago, S. [Genua Univ. Genua (Italy). 2 Clinica Ortopedica

    1999-11-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases. [Italian] Scopo di questo lavoro e' ricercare un ruolo per la defeco-TC con apparecchiatura elicoidale nello studio delle malattie del pavimento pelvico confrontandola con i risultati consolidati della defecografia tradizionale. Si sono visionati 90 pazienti, 62 femmine e 28 maschi, con eta' compresa tra 24 e 82 anni, con defecografia tradizionale; di questi, 18 casi con diagnosi dubbia sono stati studiati anche con defeco-TC spirale

  12. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  13. Synchronized control of spiral CT scan for security inspection device

    International Nuclear Information System (INIS)

    Wang Jue; Jiang Zenghui; Wang Fuquan

    2008-01-01

    In security inspection system of spiral CT, the synchronization between removing and rotating, and the scan synchronization between rotating and sampling influence quality of image reconstruction, so it is difficulty and important that how to realize synchronized scan. According to the controlling demand of multi-slice Spiral CT, the method to realize synchronized scan is given. a synchronized control system is designed, in which we use a industrial PC as the control computer, use magnetic grids as position detectors, use alternating current servo motor and roller motor as drivers respectively drive moving axis and rotating axis. This method can solve the problem of synchronized scan, and has a feasibility and value of use. (authors)

  14. Acute cholecystitis: two-phase spiral CT finding

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Eung Young; Yoon, Myung Hwan; Yang, Dal Mo; Chun Seok; Bae, Jun Gi; Kim, Hak Soo; Kim, Hyung Sik [Chungang Ghil Hospital, Incheon (Korea, Republic of)

    1998-07-01

    To describe the two-phase spiral CT findings of acute cholecystitis. Materials and Methods : CT scans of nine patients with surgically-proven acute cholecystitis were retrospectively reviewed for wall thickening, enhancement pattern of the wall, attenuation of the liver adjacent to the gallbladder, gallstones,gallbladder distension, gas collection within the gallbladder, pericholecystic fluid and infiltration of pericholecystic fat. Results : In all cases, wall thickening of the gallbladder was seen, though this was more distinct on delayed images, Using high-low-high attenuation, one layer was seen in five cases, nd three layers in four. On arterial images, eight cases showed transient focal increased attenuation of the liver adjacent to the gall bladder;four of these showed curvilinear attenuation and four showed subsegmental attenuation. One case showed curvilinear decreased attenuation between increased attenuation of the liver and the gallbladder, and during surgery, severe adhesion between the liver and gallbladder was confirmed. Additional CT findings were infiltration of pericholecystic fat (n=9), gallstones (n=7), gallbladder distension (n=6), pericholecystic fluid(n=3), and gas collection within the gallbladder (n=2). Conclusion : In patients with acute cholecystitis,two-phase spiral CT revealed wall thickening in one or three layers ; on delayed images this was more distinct. In many cases, arterial images showed transient focal increased attenuation of the liver adjacent to the gallbladder.

  15. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  16. Virtual gastroscopy using spiral CT in gastric lesions

    International Nuclear Information System (INIS)

    Shin, Sang Soo; Kang, Heoung Keun; Jeong, Yong Yeon; Yoon, Man Won; Song, Sang Gook; Jeong, Gwang Woo

    1998-01-01

    To compare virtual gastroscopy using spiral CT with conventional endoscopy for the detection and evaluation of gastric lesions. During a previous six-month period, 30 patients with pathologically-proven gastric lesions underwent conventional endoscopy and virtual gastroscopy using spiral CT. There were 18 cases of advanced gastric carcinoma, eight benign ulcers, and four submucosal tumors(two leiomyomas, two lymphomas). Source images of virtual gastroscopy were three-dim-ensionally reconstructed within an Advantage Windows Workstation and virtual gastroscopic images were obtained using Navigator Software. On analysis, images were graded according to their quality(excellent, good, poor). Virtual gastroscopic images were interpreted by two radiologists blinded to conventional endoscopic findings, and were subsequently compared with endoscopic findings in terms of detectability and findings. In the cases of advanced gastric carcinoma, lesions were classified according to Borrmann's system. For virtual gastroscopy, overall image quality was excellent in 21 cases(70%), good in five(17%), and poor in four(13%). Lesions were detected in 25 cases(83%). Among the 18 advanced gastric carcinomas, virtual gastroscopy image quality was excellent in 14 cases(78%), good in two(11%), and poor in two(11%). Lesions were detected in 16 cases(89%). Two Borrmann type IV cases were not detected. Among the eight benign ulcers, virtual gastroscopy image quality was excellent in three cases(38%), good in three(38%), and poor in two(25%). The detection of lesion was possible in five cases(63%). In all submucosal tumors, virtual gastroscopy image quality was excellent. Lesions were detected in all cases. Virtual gastroscopy using spiral CT is safe and noninvasive, and for the evaluation of gastric lesions may be complementary to axial CT. It successfully detects gastric lesions, and in depicting the pattern of gastric folds its image quality is excellent.=20

  17. Unenhanced spiral CT in Urolithiasis: indication, performance and interpretation; Native Spiral-CT bei Urolithiasis: Indikation, Durchfuehrung und Interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Thoeny, H.C. [Universitaetsspital Bern, Institut fuer Diagnostische Radiologie (Switzerland); Hoppe, H.

    2003-07-01

    Unenhanced spiral computed tomography is now applied in the investigation of patients with acute flank pain to search for suspected urinary tract calculi. Spiral CT can depict urinary calculi more accurately than plain radiographs, sonography or excretory urography, and can be performed using a low dose protocol. Almost all urinary calculi, including calculi composed of uric acid, xanthine and cystine, can be detected. In addition to determining size and location of the stone, unenhanced helical CT can predict its composition. Furthermore, it reveals secondary signs of obstruction, such as dilatation of the renal collecting system and perinephric stranding. In the absence of urolithiasis, CT can frequently detect or exclude other causes of acute flank pain, thus guiding subsequent imaging and the therapeutic management. (orig.) [German] Die Computertomographie (CT) ohne Kontrastmittelgabe findet heute bei Patienten mit akutem Flankenschmerz zunehmend Verwendung zur Abklaerung eines Konkrementes im harnableitenden System. Bezueglich ihrer Erkennungsrate von Konkrementen uebertrifft die Nativ-CT andere Untersuchungsmethoden wie die konventionelle Roentgenaufnahme, den Ultraschall oder die intravenoese Urographie und ist auch in der Niedrigdosistechnik durchfuehrbar. Nahezu saemtliche Konkremente, einschliesslich jener aus Harnsaeure, Xanthin und Cystin, koennen computertomographisch nachgewiesen werden. Neben einer Bestimmung der Konkrementgroesse und -lokalisation kann mit der Nativ-CT zusaetzlich eine Aussage ueber die Steinbeschaffenheit getroffen werden. Ferner sind auch sekundaere Zeichen einer Obstruktion wie eine Dilatation des Nierenbeckenkelchsystems oder perirenale Veraenderungen nachweisbar. Wenn kein Konkrement nachweisbar ist, lassen sich mittels der Nativ-CT-haeufig auch andere Ursachen akuter Flankenschmerzen nachweisen oder ausschliessen, wodurch eine zusaetzlich Bildgebung und das weitere therapeutische Management in die richtige Richtung gelenkt

  18. Spiral CT during pharmacoangiography with angiotensin II in patients with pancreatic disease. Technique and diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, C.; Mihara, N.; Hosomi, N.; Inoue, E.; Fujita, M. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Diagnostic Radiology; Ohigashi, H.; Ishikawa, O. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Surgery; Nakaizumi, A. [Osaka Medical Center for Cancer and Cardiovascular Deseases (Japan). Dept. of Internal Medicine; Ishiguro, S. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Pathology

    1998-03-01

    Purpose: To compare the diagnostic efficacy of pancreatic pharmacoangiographic CT using angiotensin II with conventional angiographic CT. Material and Methods: Eighteen patients with space-occupying pancreatic disease were examined in this study. Pharmacoangiographic CT was performed with a 1-3-{mu}/6-ml solution of angiotensin II injected through a catheter into the celiac artery during spiral CT. Results: In 17 of the 18 (94%) patients, the area of pancreatic parenchymal enhancement was the same or larger at pharmacoangiographic CT than at conventional angiographic CT. The attenuation value of the pancreatic parenchyma was significantly increased at pharmacoangiographic CT (p=0.0010). Although the attenuation value of tumors was also increased on images obtained after the injection of angiotensin II, the tumor-to-pancreas contrast was significantly greater at pharmacoangiographic CT (p=0.0479). The mean differences in attenuation between tumor and pancreas at angiographic CT with and without angiotensin II were respectively 182 HU and 115 HU. Conclusion: Pharmacoangiographic CT with angiotensin II proved superior to conventional angiographic CT in the diagnosis of pancreatic disease. We therefore recommend it as a supplementary technique at the angiographic examination of patients with suspected pancreatic tumor. (orig.).

  19. Visual classification of emphysema heterogeneity compared with objective measurements: HRCT vs spiral CT in candidates for lung volume reduction surgery

    International Nuclear Information System (INIS)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B.; Bergstrand, L.; Tylen, U.; Aspelin, P.

    2002-01-01

    The aim of this study was to investigate whether spiral CT is superior to high-resolution computed tomography (HRCT) in evaluating the radiological morphology of emphysema, and whether the combination of both CT techniques improves the evaluation in patients undergoing lung volume reduction surgery (LVRS). The material consisted of HRCT (with 2-mm slice thickness) and spiral CT (with 10-mm slice thickness) of 94 candidates for LVRS. Selected image pairs from these examinations were evaluated. Each image pair consisted of one image from the cranial part of the lung and one image from the caudal part. The degree of emphysema in the two images was calculated by computer. The difference between the images determined the degree of heterogeneity. Five classes of heterogeneity were defined. The study was performed by visual classification of 95 image pairs (spiral CT) and 95 image pairs (HRCT) into one of five different classes of emphysema heterogeneity. This visual classification was compared with the computer-based classification. Spiral CT was superior to HRCT with 47% correct classifications of emphysema heterogeneity compared with 40% for HRCT-based classification (p<0.05). The combination of the techniques did not improve the evaluation (42%). Spiral CT is superior to HRCT in determining heterogeneity of emphysema visually, and should be included in the pre-operative CT evaluation of LVRS candidates. (orig.)

  20. Visual classification of emphysema heterogeneity compared with objective measurements: HRCT vs spiral CT in candidates for lung volume reduction surgery

    Energy Technology Data Exchange (ETDEWEB)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B. [Department of Thoracic Radiology, Karolinska Hospital, Stockholm (Sweden); Bergstrand, L. [Department of Radiology, Danderyds Hospital, Danderyd (Sweden); Tylen, U. [Deparment of Radiology, Sahlgrenska University Hospital, Gothenberg (Sweden); Aspelin, P. [Department of Radiology, Huddinge University Hospital, Huddinge (Sweden)

    2002-05-01

    The aim of this study was to investigate whether spiral CT is superior to high-resolution computed tomography (HRCT) in evaluating the radiological morphology of emphysema, and whether the combination of both CT techniques improves the evaluation in patients undergoing lung volume reduction surgery (LVRS). The material consisted of HRCT (with 2-mm slice thickness) and spiral CT (with 10-mm slice thickness) of 94 candidates for LVRS. Selected image pairs from these examinations were evaluated. Each image pair consisted of one image from the cranial part of the lung and one image from the caudal part. The degree of emphysema in the two images was calculated by computer. The difference between the images determined the degree of heterogeneity. Five classes of heterogeneity were defined. The study was performed by visual classification of 95 image pairs (spiral CT) and 95 image pairs (HRCT) into one of five different classes of emphysema heterogeneity. This visual classification was compared with the computer-based classification. Spiral CT was superior to HRCT with 47% correct classifications of emphysema heterogeneity compared with 40% for HRCT-based classification (p<0.05). The combination of the techniques did not improve the evaluation (42%). Spiral CT is superior to HRCT in determining heterogeneity of emphysema visually, and should be included in the pre-operative CT evaluation of LVRS candidates. (orig.)

  1. [Evaluation of non-enhanced spiral CT in the assessment of renal colic: prospective series of 81 patients].

    Science.gov (United States)

    Anfossi, Eric; Eghazarian, Christophe; Portier, François; Prost, Jérôme; Ragni, Evelyne; Daou, Nabil; Rossi, Dominique

    2003-02-01

    For many years, intravenous urography has been the first-line investigation for renal colic. Since the middle of the 1990s, non-enhanced spiral CT has become a more efficient, less invasive and less expensive alternative to IVU. The aim of this study was to compare non-enhanced spiral CT and IVU in the assessment of renal colic and to evaluate the possibility of exclusive CT assessment in this disease. Prospective study including 81 patients all undergoing urgent non-enhanced spiral CT, while the first 30 patients were investigated by non-enhanced spiral CT and IVU. Comparison of IVU versus CT: better sensitivity of CT for the diagnosis of renal colic (96% vs 92%) and for the detection of stones (95% vs 59%). CT diagnosis: A definitive diagnosis of renal colic was established in 72/81 patients: stone visualized in 64 cases and post colic syndrome in 8 cases, while the other 9 patients presented a non-urological abdominal disease. Comparison of our series with results reported in the literature confirms the superiority of CT over IVU with better visualization of the stone at a lower cost, with a shorter examination time, without injection and allowing the detection of non-urological disease. Analysis of CT signs emphasizes the importance of secondary signs for the diagnosis of renal colic (dilatation, perirenal or ureteric oedema, rim sign). Delayed excretion demonstrated by IVU and not directly evaluable by non-enhanced CT is no longer an argument in favour of IVU as first-line examination for the assessment of renal colic. The superiority of CT for the diagnosis of renal colic has now been demonstrated. Renal colic can now be assessed exclusively by first-line non-enhanced helical CT. IVU or contrast-enhanced CT may be indicated in rare cases when there is a doubt about the diagnosis on non-enhanced CT.

  2. Three-dimensional spiral CT of craniofacial malformations in children

    International Nuclear Information System (INIS)

    Binaghi, S.; Gudinchet, F.

    2000-01-01

    Objective. To assess the value of three-dimensional CT (3D CT) in the diagnosis and management of suspected paediatric craniofacial malformations. Materials and methods. Twenty-eight children (12 girls, 16 boys) with a mean age of 4 years, suffering from craniofacial or cervical malformations, underwent craniofacial spiral CT. 3D reformatting was performed using an independent workstation. Results. 3D CT allowed the preoperative evaluation of 16 patients with craniosynostosis and the post-surgical management of 2 patients. 3D CT clearly depicted malformations of the skull base involving the petrous bone in seven patients (four cases of Goldenhar-Gorlin syndrome, one case of Treacher-Collins syndrome and two cases of Crouzon's disease). Four patients with craniofacial clefts were also evaluated. Radiological findings were confirmed by the clinical and intraoperative findings in all patients that underwent surgical treatment. Movement artefacts and ''Lego effect'' related to abrupt change of cranial vault border were encountered and are discussed. Conclusions. 3D CT of the skull can safely and reliably identify paediatric craniofacial malformations involving bone, and it should be used as morphological mapping to help the surgeon in planning surgical treatment. (orig.)

  3. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  4. Comparison and analysis on patient dose of gemston spectral CT and ordinary spiral CT in a hospital

    International Nuclear Information System (INIS)

    Cheng Xiaojun; Ding Li

    2014-01-01

    This article compared the difference of CTDI and DLP in chest routine scan detected by dose testing system between gemston spectral CT and 16-slice spiral CT in a hospital, the result showed there was no significant difference. (authors)

  5. Establishment of an orthotopic lung cancer model in nude mice and its evaluation by spiral CT.

    Science.gov (United States)

    Liu, Xiang; Liu, Jun; Guan, Yubao; Li, Huiling; Huang, Liyan; Tang, Hailing; He, Jianxing

    2012-04-01

    To establish a simple and highly efficient orthotopic animal model of lung cancer cell line A549 and evaluate the growth pattern of intrathoracic tumors by spiral CT. A549 cells (5×10(6) mL(-1)) were suspended and inoculated into the right lung of BALB/c nude mice via intrathoracic injection. Nude mice were scanned three times each week by spiral CT after inoculation of lung cancer cell line A549. The survival time and body weight of nude mice as well as tumor invasion and metastasis were examined. Tissue was collected for subsequent histological assay after autopsia of mice. The tumor-forming rate of the orthotopic lung cancer model was 90%. The median survival time was 30.7 (range, 20-41) days. The incidence of tumor metastasis was 100%. The mean tumor diameter and the average CT value gradually increased in a time-dependent manner. The method of establishing the orthotopic lung cancer model through transplanting A549 cells into the lung of nude mice is simple and highly successful. Spiral CT can be used to evaluate intrathoracic tumor growth in nude mice vividly and dynamically.

  6. Spiral CT in diagnosing of heavier forms of lung tuberculosis in childhood

    International Nuclear Information System (INIS)

    Miladinovska, S.; Grunevski, M.; Temelkovska, S; Dilberovska, M.; Jovanovski, D.

    2003-01-01

    Purpose: We show several cases od severe forms of tuberculosis of the lung, diagnosed with spiral CT. Material and methods: We elaborated selected material of heavier forms of lung tuberculosis for a period of 5 years (1998 - 2002( in children at the age 0 - 16 years that we treated at our hospital at the department for lung TBC. Among other examinations such as laboratory, microbiological, Mantu test, also conventional X ray in PA and lateral projection was done in all patients. In the more severe form of lung TBC also spiral CT was performed for achieving the precise diagnose. Results: From totally 761 diagnosed patients with primary and post-primary TBC in 14 patients it was necessary to perform spiral CT. The results were as follows: We proved specific endo bronchitis in 5 cases; cavernous hollowness in 9 cases; pleural exudation in 6 cases. In 1 patient besides TBC we diagnosed a congenital anomaly of the lung. In 1 patient besides TBC of the lung we diagnosed TBC on the vertebral body with kyphosis. Discussion: Tuberculosis is of great economical and social importance. The conventional x ray test is often sufficient when diagnosing TBC. In exceptional cases in the initial forms, for confirming of the diagnose, it is necessary to perform also CT

  7. Borrmann type IV adenocarcinoma versus gastric lymphoma : spiral CT evaluation

    International Nuclear Information System (INIS)

    Seo, Bo Kyoung; Kim, Yun Hwan; Shin, Kue Hee; Hong, Suk Joo; Kim, Hong Weon; Park, Cheol Min; Chung, Kyoo Byung; Cho, Hyun Deuk

    1999-01-01

    To distinguish the spiral CT findings of Borrmann type IV adenocarcinoma from those of gastric lymphoma with diffuse gastric wall thickening. We retrospectively reviewed the spiral CT scans of 30 patients with Borrmann type IV adenocarcinoma and nine with gastric lymphoma with diffuse gastric wall thickening. In all patients the respective condition was pathologically confirmed by gastrectomy. CT scanning was performed after peroral administration of 500-700ml of water. A total of 120-140 ml bolus of nonionic contrast material was administered intravenously at a flow rate of 3 ml/sec and two-phase images were obtained at 35-45 sec(early phase) and 180 sec(delayed phase) after the start of bolus injection. Spiral CT was performed with 10mm collimation, 10mm/sec table feed and 10mm reconstruction. We evaluated the degree and homogeneity of enhancement of thickened entire gastric wall, and the enhancement pattern of gastric inner layer, as seen on early-phase CT scans. On early and delayed views, the thickness of gastric wall and the presence of perigastric fat infiltration were determined. The enhancement patterns of gastric inner layer were classified as either continuous or discontinuous thick enhancement, thin enhancement, or nonenhancement. The thickness of gastric wall was 1.2-3.5cm(mean 2.2cm) in cases of adenocarcinoma and 1.2-7.6cm(mean 4cm) in lymphoma. Perigastric fat infiltration was seen in 24 patients with adenocarcinoma(80%) and four with lymphoma(44%). In those with adenocarcinoma, the degree of enhancement of entire gastric wall was hyperdense in fifteen patients(50%) and isointense in eleven (37%). Seven patients with lymphoma(78%)showed hypodensity. In those with adenocarcinoma, continuous thick enhancement of gastric inner layer was seen in 18 patients(60%) and discontinuous thick enhancement in nine(30%). In lymphoma cases, no thick enhancement was observed. Thin enhancement of gastric inner layer was demonstrated in three patients with

  8. Virtual endoscopy using spiral CT in patients with carcinomas of the hypopharynx and larynx

    International Nuclear Information System (INIS)

    Song, Sang Gook; Seo, Jeong Jin; Chung, Tae Woong; Kim, Hyeong Kil; Jeong, Gwang Woo; Jeong, Yong Yeon; Kang, Heoung Keun; Cho, Jae Sik

    2000-01-01

    To compare the usefulness of virtual endoscopy using spiral CT with that of laryngoscopy in the detection and evaluation of laryngeal and pharyngeal carcinomas. Twenty-four patients with pathologically proven laryngeal and pharyngeal carcinomas underwent laryngoscopy and virtual endoscopy using spiral CT. Eleven of the carcinomas were supraglottic, five were glottic, and eight were hypopharyngeal. Source images obtained by spiral CT were transmitted to an independent workstation and virtual endoscopic images were obtained using Navigator software. These were graded according to their quality (good, fair, bad), and were interpreted by two radiologists who were blinded to the conventional endoscopic findings. These latter were subsequently compared with the virtual endoscopic findings in terms of similarity to laryngoscopic examination and detectability of lesions. The overall image quality of virtual endoscopy was good in 16 cases (67%), fair in eight (33%), and bad in no case. Among the 11 supraglottic carcinomas, image quality was good in seven cases (64%), and fair in four (36%). In four of the five glottic carcinomas (80%) quality was good, and in one case (20%) it was fair, while among the eight hypopharyngeal carcinomas, quality was good in five cases (63%), and fair in three (37%). Overall, detection of the lesion was possible in 23 cases (96%). Due to the small size of the lesion, the one case of glottic carcinoma was not detected. Virtual endoscopy using spiral CT is a safe and noninvasive method, and also successfully detects laryngeal and pharyngeal lesions, with good image quality. For the evaluation of laryngeal and hypopharyngeal carcinoma, its use ma complement that of axial CT. (author)

  9. Comparison of spiral CT angiography vs digital subtraction angiography in the evaluation of living kidney donors

    Directory of Open Access Journals (Sweden)

    Santosh Kumar

    2002-01-01

    Full Text Available Recent reports suggest that spiral computed tomographic (CT angiography could replace conventional angiogra-phy and intravenous urography (IVU for the assessment of potential live kidney donors. The purpose of this study was to assess the accuracy of spiral CT in kidney donor workup. 10 consecutive renal donors had IVU, percutane-ous transfemoral selective renal angiography and spiral CT angiography between January and March 2001. The spiral CT and renal angiograms were assessed independ-ently by two radiologists. The number of renal arteries, pres-ence or absence of renal artery stenoses and associated parenchymal abnormalities were assessed. A total of 27 renal arteries were detected. Transverse scans viewed in a tine loop format with maximum intensity projection and shaded surface display detected all 27 vessels. All 27 ves-sels were detected by conventional catheter angiography. A simple renal cyst was noted in both spiral CT and con-ventional angiogram. Venous anatomy including a retroaortic renal vein was visualized in spiral CT angiogram but not visualized by conventional angiography. Spiral CT angiography performed as an outpatient procedure is less invasive, less expensive, and provides good images of the arterial and venous anatomy in addition to the visualiza-tion of the other abdominal viscera. A plain X-ray of the abdomen was taken 15 rains after injection of contrast to acquire an IVU like image. Spiral CT angiography has the potential to replace conventional catheter angiography and IVU in the assessment of renal donors.

  10. Detection of colorectal liver metastases: a prospective multicenter trial comparing unenhanced MRI, MnDPDP-enhanced MRI, and spiral CT

    International Nuclear Information System (INIS)

    Bartolozzi, Carlo; Donati, Francescamaria; Cioni, Dania; Lencioni, Riccardo; Procacci, Carlo; Morana, Giovanni; Chiesa, Antonio; Grazioli, Luigi; Cittadini, Giorgio; Cittadini, Giuseppe; Giovagnoni, Andrea; Gandini, Giovanni; Maass, Jochen

    2004-01-01

    The aim of this study was to compare unenhanced MRI, MnDPDP-enhanced MRI, and spiral CT in the detection of hepatic colorectal metastases. Forty-four patients with hepatic colorectal metastases were examined with unenhanced and MnDPDP-enhanced MRI and with unenhanced and contrast-enhanced spiral CT. The MR examination protocol included baseline T1-weighted spin-echo (SE), T1-weighted gradient-recalled-echo (GRE), and T2-weighted fast-SE sequences; and T1-weighted SE and T1-weighted GRE sequences obtained 30-60 min after administration of 0.5 μmol/kg (0.5 ml/kg) mangafodipir trisodium (MnDPDP). Images were interpreted by three blinded readers. Findings at CT and MRI were compared with those at intraoperative US, which were used as term of reference. Intraoperative US detected 128 metastases. In a lesion-by-lesion analysis, the overall detection rate was 71% (91 of 128) for spiral CT, 72% (92 of 128) for unenhanced MRI, and 90% (115 of 128) for MnDPDP-enhanced MRI. MnDPDP-enhanced MRI was more sensitive than either unenhanced MRI (p<0.0001) or spiral CT (p=0.0007). In a patient-by-patient analysis, agreement with gold standard was higher for MnDPDP-enhanced MRI (33 of 44 cases) than for spiral CT (22 of 44 cases, p=0.0023) and unenhanced MRI (21 of 44 cases, p=0.0013). MnDPDP-enhanced MRI is superior to unenhanced MRI and spiral CT in the detection of hepatic colorectal metastases. (orig.)

  11. The anal verge: localization with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Wang Wei; Tang Guangjian

    2010-01-01

    Objective: To determine and evaluate the method of localization of anal verge by multislice spiral CT. To provide an imaging reference for operative guidance of low-rectal cancer. Methods Forty eight consecutive adult patients suspected of abnormalities other than rectal disease were evaluated with abdominal and pelvic CT scans since August, 2009. They were divided into two groups based on sex and age. There were 23 men and 25 women. The ages of young group were 28 to 50 years and the average age was 41 years. The ages of elderly group were 52 to 81 years and the average age was 64 years. A small cotton ball dipped with contrast media was put at the anal verge as a marker and CT scans were performed with 64-slice spiral CT scanner. The distances between the cotton balls and the lower margin of the pubis combination (La), the lower margin of the Sth sacral vertebra (Lb), the inferior aperture of minor pelvis (Lc) and the lower margin of the basement of external anal sphincter (Ld) were measured on the mid- sagittal images obtained by MPR. The averages, the standard deviations (s), the 95% and 80% confidence intervals of La, Lb, Lc and Ld were calculated. We took the intervals of ±1.96 s or ±1.28 s 0.05) between two different sex groups [male group, (10.0±1.2) mm], female group, (9.6±1.2) mm and between two age groups [young group, (9.6±1.2) mm, elderly group, (9.9±1.3) mm]. Conclusions: The lower margin of the basement of external anal sphincter was a useful anatomic landmark for localizing the anal verge, and could be definitely identified on the middle sagittal pelvic CT image. The distance between the structure and anal verge is constant enough and can be used in measuring distance from low rectal lesion to the anal verge. (authors)

  12. Motion estimation and compensation in dynamic spiral CT reconstruction

    International Nuclear Information System (INIS)

    Kimdon, J.; Grangeat, P.; Koenig, A.; Bonnet, St.

    2004-01-01

    Respiratory and cardiac motion causes blurring in dynamic X-ray Computed Tomography (CT). Fast scans reduce this problem, but they require a higher radiation dose per time period to maintain the signal to noise ratio of the resulting images, thereby magnifying the health risk to the patient. As an alternative to increased radiation, our team has already developed a cone-beam reconstruction algorithm based on a dynamic particle model that estimates, predicts, and compensates for respiratory motion in circular X-ray CT. The current paper presents an extension of this method to spiral CT, applicable to modern multi-slice scanners that take advantage of the speed and dose benefits of helical trajectories. We adapted all three main areas of the algorithm: backprojection, prediction, and compensation/accumulation. In backprojection, we changed the longitudinal re-binning technique, filter direction, and the method of enforcing the data sufficiency requirements. For prediction, we had to be careful of objects appearing and disappearing as the scanner bed advanced. For compensation/accumulation, we controlled the reconstruction time and combined images to cover a greater longitudinal extent for each phase in the respiratory or cardiac cycle. Tests with moving numerical phantoms demonstrate that the algorithm successfully improves the temporal resolution of the images without increasing the dose or reducing the signal-to-noise ratio. (authors)

  13. Hypoxic-ischemic encephalopathy in neonates and infants: an evaluation with spiral CT

    International Nuclear Information System (INIS)

    Zhu Linghua

    2006-01-01

    Objective: To evaluate spiral CT imaging in the diagnosis of hypoxic-ischemic encephalopathy (HIE) in the neonates and infants. Methods: 112 children with history of asphyxia in peri-natal period and evident clinical symptoms were evaluated with Spiral CT. CT findings were studied. Results: 46 minor cases, 57 moderate cases and 9 severe cases were found out of 112 patients. Intracranial hemorrhage was revealed in 38 cases. Mortality occurred in 1 case. Conclusion: Spiral CT is helpful for evaluating brain damage and predicting prognosis in neonates with HIE. (authors)

  14. Induced pneumoperitoneum in spiral CT evaluation of gastric cancer

    International Nuclear Information System (INIS)

    Guo Hua; Gao Jianbo; Li Yintai; Yang Xuehua; Chen Xuejun; Guan Sheng

    2001-01-01

    Objective: To evaluate the diagnostic value and clinical significance of preoperative staging in gastric cancer with induced pneumoperitoneum in spiral CT (SCTPP). Methods: Both routine SCT and SCTPP were performed in 52 lean patients suffered from gastric cancers, and comparison was made between SCT findings and surgical and histopathologic findings. Results: The accuracy of routine SCT and SCTPP in determining the T-staging was 72% and 96%, respectively (x 2 = 8.0, P 2 = 0.006, P > 0.05). The sensitivity in determining M-staging was 61% and 100%, respectively (x 2 = 0.04, P 2 6.03, P < 0.05). Conclusion: The accuracy of SCTPP in determining preoperative staging of gastric cancer was significantly higher than that of routine SCT. SCTPP has important guiding significance for the selection of the treatment strategy in gastric cancer

  15. Nonfunctioning endocrine tumors of the pancreas: possibilities of spiral CT characterization

    Energy Technology Data Exchange (ETDEWEB)

    Procacci, C.; Carbognin, G.; Biasiutti, C.; Bicego, E.; Romano, L.; Guarise, A.; Minniti, S.; Pagnotta, N. [Dept. of Radiology, University of Verona Medical School (Italy); Accordini, S. [Div. of Medical Statistics, University of Verona Medical School (Italy); Falconi, M. [Dept. of Surgical Sciences, University of Verona Medical School (Italy)

    2001-07-01

    The aim of this study was to assess the ability of spiral CT to adequately characterize the nonfunctioning endocrine tumors (NFETs) of the pancreas, distinguishing this lesion from the other pancreatic tumors. The spiral CT examinations of 21 cases of histologically proven NFETs, along with those of 29 cases of other pancreatic tumors and tumor-like lesions, were retrospectively reviewed in a blinded fashion by two radiologists, in order to correctly classify the lesions, highlighting the typical signs reported in the literature. Discordant cases were further analyzed in the presence of a third radiologist. The final diagnosis was acquired by means of a majority or overall consensus. The histopathologic examination was considered the gold standard. The sensitivity, specificity, and positive and negative predictive values of CT were calculated. After the consensus evaluation, the correct diagnosis was reached in 72% of cases, with 10% of nonspecific diagnoses of solid pancreatic tumor and 18% of wrong diagnoses. The sensitivity and specificity of spiral CT in identifying NFETs were 66.6 and 82.7%, respectively. The positive and negative predictive values were 73.7 and 77.4%, respectively. In up to 70% of cases the NFET demonstrates a typical aspect of a mass hyperdense in the arterial contrastographic phase eventually associated with hyperdense hepatic metastases in more than half of the patients. This finding does allow the diagnosis of NFET but without certainty indeed, since other tumors can show a similar densitometric behavior and among them particularly the ductal adenocarcinoma. On the other hand, both the solid, hypovascularized NFETs, and the cystic form, cannot be differentiated from the other solid and cystic tumors of the pancreas. (orig.)

  16. Spiral CT of the neck: When do neck malignancies delineate best during contrast enhancement?

    International Nuclear Information System (INIS)

    Keberle, M.; Tschammler, A.; Hahn, D.; Berning, K.

    2001-01-01

    The aim of this study was to determine the time of best contrast of neck malignancies in contrast-enhanced CT. The CT was done in 20 patients with squamous cell carcinoma using a standard protocol (100 ml contrast agent at 2 ml/s). Dynamic series of the tumors were performed (scan interval 6 s). In all relevant structures of the neck, densities were measured to obtain time-density curves. The best tumor contrast was measured ≥50 s after the start of the injection, and the best contrast of lymph nodes ≤75 s. For staging and volume measurements of neck primaries the best achievable contrast is necessary. Using the examined single-bolus technique, spiral CT allows a combination of perfect tumor contrast with a good contrast between lymph nodes and neck vessels between 50 and 75 s after starting the injection. (orig.)

  17. Evaluation of spiral CT in staging of colon and rectum carcinoma

    International Nuclear Information System (INIS)

    Hundt, W.; Braunschweig, R.; Reiser, M.

    1999-01-01

    The purpose of our study was to evaluate the capability of a subsecond spiral-CT scanner using two contrast medium phases in staging of colorectal cancer. In our study we included 37 patients with proven rectum or colon carcinoma. Spiral CT was performed following tap-water enema of the colon in the arterial and venous phases of contrast medium enhancement. Our results were compared with the findings of pathological examination after surgery. The tumor's size and extension were evaluated in the arterial and venous phases, the lymph nodes in the venous phase of the CT scan. The tumor was in the rectum (n = 14), sigma (n = 11), descending colon (n = 6), and cecum (n = 6). Two-phase spiral CT had a sensitivity of 97.2 % in the arterial phase and 89.1 % in the venous phase in detecting the carcinoma. The staging results were in the arterial phase in 30 of 37 cases (81.0 %) and in the venous phase in 24 of 37 cases (64.8 %) according to pathology. In 27 of 32 patients (84.3 %) lymph nodes were detected. The correct classification of the N-stage was possible in 23 of 34 cases (67.6 %). The combined use of arterial and venous phases in staging of colorectal cancer can improve the T- and N-stage classification in comparison with using only one contrast medium phase. The arterial phase is superior compared with the venous phase for local tumor staging and the venous phase is used for lymph node assessment. (orig.) (orig.)

  18. CT examination of the kidneys

    International Nuclear Information System (INIS)

    Handa, Youji; Ishida, Ken; Arita, Takeshi; Ishine, Kenji; Tezen, Takashi; Ohta, Nobuhiro

    1985-01-01

    Plain CT scanning of the kidney was performed in 16 patients with renal failure whose basic renal disorder had been not necessarily known beforehand. The findings of the CT examination were composed of renal atrophy of various degree (12 cases), cystic lesions (8 cases), polycystic renal disease (one case), nephrosclerosis (2 cases), hydronephrosis (2 cases), ureter and renal stones (one case), and normal CT profile (2 cases). Being based on these CT findings and other clinical informations, basic renal disorders could be either presumed or confirmed. It was concluded that plain CT scanning of the kidney was useful to decide a method of treatment and to estimate prognosis in patients with renal failure. (author)

  19. Segmental and subsegmental pulmonary arteries: evaluation with electron-beam versus spiral CT.

    Science.gov (United States)

    Schoepf, U J; Helmberger, T; Holzknecht, N; Kang, D S; Bruening, R D; Aydemir, S; Becker, C R; Muehling, O; Knez, A; Haberl, R; Reiser, M F

    2000-02-01

    To compare contrast agent-enhanced spiral and electron-beam computed tomography (CT) for the analysis of segmental and subsegmental pulmonary arteries. CT angiography of the pulmonary arteries was performed in 56 patients to rule out pulmonary embolism. Electron-beam CT was performed in 28 patients. The other 28 patients underwent spiral CT with comparable scanning protocols. The depiction of segmental and subsegmental arteries was analyzed by three independent readers. The contrast enhancement in the main pulmonary artery was measured in each patient. Analysis was performed in 1,120 segmental and 2, 240 subsegmental arteries. One segmental (RA7, P =.010) and two subsegmental (LA7b, P =.029; RA6a+b, P =.038) arteries in paracardiac and basal segments of the lung were depicted significantly better with electron-beam CT. There was no statistically significant difference between electron-beam and spiral CT in the total number of analyzable peripheral arteries depicted. The mean contrast enhancement in the main pulmonary artery was 362 HU in electron-beam CT studies versus 248 HU in spiral CT studies. Detailed visualization of peripheral pulmonary arteries is well within the scope of advanced CT techniques. Electron-beam CT has minor advantages in analyzing paracardiac arteries, probably because of reduction of motion artifacts and higher contrast enhancement. Further studies are needed to establish whether electron-beam CT allows a more confident diagnosis of emboli in these vessels.

  20. Application of multislice spiral CT in children urinary tract injuries

    International Nuclear Information System (INIS)

    Feng Hui; Chen Jing

    2012-01-01

    Objective: To investigate the application value of three-dimensional reconstruction technique of multislice spiral CT(MSCT) in children urinary tract injuries. Methods: Forty-three patients with urinary tract injury performed MSCT scan, and three-dimensional reconstruction technique was used for volume rendering, maximum intensity projection and multi-planar reformation, urinary tract imaging was acquired completely. The images were reviewed by two experienced radiologists. Results: Of the 43 cases,there were 5 simple contusion of kidney, 5 contusion and laceration of kidney accompanied with subcapsular haematoma, 4 contusion and laceration of kidney accompanied with perinephric haematoma, 2 contusion and laceration of kidney accompanied with adrenal haematoma, 13 shattered kidney accompanied with extravasation of urine, 3 shattered kidney accompanied with renal pedicle injury, 6 shattered kidney accompanied with ureter injury, 2 pelvic fracture accompanied with posterior urethra split, 3 contusion of urinary bladder wall accompanied with blood clot in the urinary bladder. Conclusion: MSCT has the characteristic of high scanning speed, wide overlay scope,high image quality and thin slice scan. It is an effective modality in the evaluation of children urinary tract injuries. (authors)

  1. Improvement in printing technique of spiral CT three-dimensional colour image

    International Nuclear Information System (INIS)

    Wang Yicheng; Liu Feng; Zhang Ling

    2005-01-01

    Objective: To investigate the printing technique of spiral CT three-dimensional (3D) colour image. Methods: The 3D colour images of 136 patients were printed, with the equipment of Marconi spiral CT, personnel computer, colour ink printer, and network switchboard. Results: All printed images were satisfied by this method. Conclusion: This technique is economic, simple, and useful, and can meet the need for clinical diagnosis and operation. (authors)

  2. Value of spiral CT in the treatment of aortic dissection with endovascular exclusion

    International Nuclear Information System (INIS)

    Zhao Jun; Jing Zaiping; Xiao Yi; Wang Peijun

    2001-01-01

    Objective: To discuss the value of spiral CT in the preoperative evaluation of Stanford type B dissections before treated with endovascular exclusion. Methods: Thirty-one cases of consecutive Stanford type B dissecting thoracic aortic aneurysms were retrospectively studied by reviewing of the multi-reconstructive Spiral CT images. The image reconstruction methods were dimensional transverse enhanced scanning, maximum-pixel-intensity projection (MIP), surface rendered display (SSD), curved planer reformatting (CPR), and Virtual Endoscopic Imaging (VEI). Results: Sensitivity of revealing the tears of the dissection by Spiral CT was 100%. The ratio of identifying the true and false lumen was 100%. Location of the proximal tears in 29 of the 31 cases displayed on Spiral CT images were the same as that of on digital subtracting angiography, which achieved an accurate ratio of 93.5%. though the location of the proximal tears in two of the 31 cases detected by CT scanning did not match to that of DSA, the operation decision or stent-grafts selection were not affected. The detection of the range of the dissections by CT achieved a ratio of 100%, and the size chosen of the stent-graft based on CT parameters was all correct that in a ratio of 100%. Conclusion: The spiral CT is of high value in the preoperative evaluation of endovascular exclusion for thoracic aortic dissection. It can act as the routine method of choice

  3. Diagnosis and staging of carcinoma localized in the antral part of the stomach with spiral CT

    International Nuclear Information System (INIS)

    Pomakov, P.; Grudeva, V.; Mlachkova, D.

    2009-01-01

    The aim of the study was to characterize CT images and stages of carcinomas localized in the antral part of the stomach obtained with spiral CT. Seven men aged from 54 years old to 81 years old inclusive, with subjective complaints and clinical suspicion of a neoplasm in the upper gastrointestinal tract were examine Examinations were performed following stomach wall re relaxation with Buscolysin.The stomach is distended by drinking 600 ml of water. Upper abdomen scans were performed with spiral CT/e General Electric with the following parameters: slice thickness 3-5 mm, spacing 3 mm, pitch 1,5, reconstruction index 3 mm. After the pre-contrast scans, 100 ml of non-ionic contrast media is administered intravenously with an injection rate of 30 ml/sec. Scan delay time - 30 seconds after start of injection. Exposition data-120 kV, 180 mAs. Carcinoma localized in the antral part of the stomach was demonstrated in 7 patients. The staging showed: I stage - one patient, II stage - 2, III stage - 1 and IV stage - three patients. According to the macro morphological characteristic: exophytic type - 4, endophytic tumor - 1, ulcerous tumor - 1 and early carcinoma - 1 patient. In our material only male patients were present. Early carcinoma was demonstrated in a male patient at an age of 80 years old. An enhancing nodular local thickness was visualized. Differential diagnosis between malignant and benign ulcer is necessary in certain cases. It is performed on the contrast scans, the malignant process enhances twice its density, When performing a purposive CT examination it is possible to diagnose neoplasms in the antral part of the stomach, from stage i to IV with different macro morphologic characteristic

  4. The role of spiral CT in patients with intermediate probability V/Q scans: can spiral CT replace pulmonary angiography?

    International Nuclear Information System (INIS)

    Vu, T.; Glenn, D.; Lovett, I.; Moses, J.; Wadhwa, S.S.; Nour, R.

    2000-01-01

    Full text: Spiral CT (SCT) has been advocated as a replacement for pulmonary angiography (PA)in patients with intermediate probability (IP) ventilation-perfusion lung scans (V/Q). More generally it has been proposed as a replacement for V/Q to detect Pulmonary Embolism. This study investigates the accuracy of SCT in the IP patient group 31 patients with IP scans (Modified PIOPED criteria) who were not at high risk of contrast nephrotoxicity were enrolled to have both SCT and PA within the 24 hours following their V/Q. Patients were classified as IP due to a single segmental mismatch (n=7) or a matched V/Q abnormality corresponding to CXR opacity (n=21), or both (n=3). PA is the gold standard for the detection of PE. SCT was read by an experienced radiologist blinded to the PA results. SCT was performed according to standard protocol. All SCT were technically satisfactory for interpretation. Pulmonary embolism was present in 9/31 patients (29%). Of the patients with PE detected by PA, SCT was positive in 4 (44% sensitivity). Of the 22 patients who did not have PE, SCT was negative in 21 and positive in one (96% specificity). In conclusion SCT has limited sensitivity for the detection of PE in patients with IP lung scans. SCT may not be an adequate replacement for PA. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. Three-dimensional computed display of otosurgical operation sites by spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, O. [Department of Otorhinolaryngology, University of Heidelberg Medical School, Heidelberg (Germany); Sartor, K. [Department of Neuroradiology, University of Heidelberg Medical School (Germany); Forsting, M. [Department of Neuroradiology, University of Heidelberg Medical School (Germany); Reisser, C. [Department of Otorhinolaryngology, University of Heidelberg Medical School, Heidelberg (Germany)

    1996-10-01

    We studied the usefulness of spiral CT for preoperative information on the individual anatomy of the temporal bone in a computed three-dimensional (3D) display. In 87 patients with various otological diseases, 3D reconstructions were performed based on spiral high-resolution CT (HR-CT) by volume-rendering on an independent workstation. The positions of the ossicles, facial nerve, labyrinth and vestibular aqueduct relative to reference points were comprehensively demonstrated by thresholding or interactive segmentation. Spiral CT enables 3D display of otosurgical operation sites in a shorter scan time than conventional CT. 3D reconstructions improve the surgeon`s understanding of individual anatomy and thus help in surgical planning. This is particularly important for surgery of temporal bone tumours, middle ear deformities, cochlear implants and saccotomy. (orig.). With 6 figs.

  6. Three-dimensional computed display of otosurgical operation sites by spiral CT

    International Nuclear Information System (INIS)

    Schubert, O.; Sartor, K.; Forsting, M.; Reisser, C.

    1996-01-01

    We studied the usefulness of spiral CT for preoperative information on the individual anatomy of the temporal bone in a computed three-dimensional (3D) display. In 87 patients with various otological diseases, 3D reconstructions were performed based on spiral high-resolution CT (HR-CT) by volume-rendering on an independent workstation. The positions of the ossicles, facial nerve, labyrinth and vestibular aqueduct relative to reference points were comprehensively demonstrated by thresholding or interactive segmentation. Spiral CT enables 3D display of otosurgical operation sites in a shorter scan time than conventional CT. 3D reconstructions improve the surgeon's understanding of individual anatomy and thus help in surgical planning. This is particularly important for surgery of temporal bone tumours, middle ear deformities, cochlear implants and saccotomy. (orig.). With 6 figs

  7. [Complex maxillofacial trauma: diagnostic contribution of multiplanar and tridimensional spiral CT imaging].

    Science.gov (United States)

    Preda, L; La Fianza, A; Di Maggio, E M; Dore, R; Schifino, M R; Mevio, E; Campani, R

    1998-09-01

    Adequate radiologic assessment of the maxillofacial trauma patient is the basis for planning reparative surgery. We investigated the yield of the integration of axial CT with multiplanar (MP) and three-dimensional (3D) reconstructions with the Spiral technique. Thirty-five patients (21 men and 14 women, mean age: 31.2 years) with complex maxillofacial traumas were submitted to Spiral CT. Images were acquired with 2-3-mm collimation, 1:1 to 2:1 pitch, 210 mAs, 120 kV, 15-24 s Spiral scan, RI = 1. 3D reconstructions were always obtained and used to guide MPRs targeted on the single injury. The examinations were retrospectively given a score, namely 1 if 3D and MPR yielded no more important diagnostic information than axial CT, 2 if 3D and MPR permitted better detailing of some axial CT findings and thus improved image reading, and 3 if 3D and MPR showed new injuries missed on axial images. Then, a radiologist and a maxillofacial surgeon reviewed the 3D images together only to assess in which cases they were useful to optimize surgical planning. Nine cases (25.7%) scored 1, seventeen (48.6%) scored 2 and nine (25.7%) scored 3. MP and 3D reconstructions were useful or determinant (2 + 3) in over 74% of cases. 3D images made surgical planning easier in 15 of 32 surgical patients (46.8%), allowing the surgeon a better panoramic view of the complex fracture. The greatest advantage of multiplanar imaging is the improved depiction of skeletal injuries along a horizontal plane, paralleling that of axial scans. The depiction of fractures of cribrum and of orbital roof and floor was particularly useful from a clinical viewpoint. MPRs clearly depicted herniation and incarceration of the lower rectus muscle in blow-out fractures. MP and 3D reconstructions better defined the presence and grade of displaced bone fragments in nearly vertical structures, such as the upward branches and coronoid apophysis of the mandible. 3D images alone never showed any more fractures than those

  8. Enhancement pattern of small hepatic hemangioma: findings on multiphase spiral CT and dynamic MRI

    International Nuclear Information System (INIS)

    Choi, Byung In; Lee, Seung Koo; Kim, Myeong Jin; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To compare the enhancement characteristics of small hemangiomas seen on multiphase spiral CT and dynamic MR imaging. Thirteen patients with 20 hepatic hemangiomas less than 25mm in diameter underwent both multiphase spiral CT and dynamic MR imaging. All lesions were assigned to one of three classified into 3 categories according to the enhancement pattern seen on multiphase spiral CT : typical delayed pooling, atypical early enhancement, or continuous low attenuation. The enhancement patterns seen on spiral CT and on dynamic MRI were correlated. On CT scans, ten lesions (50%) showed delayed pooling. Six (30%) showed early arterial enhancement and four (20%) showed continuous low attenuation. On delayed-phase MRI, all lesions showed delayed high signal intensity compared to adjacent liver parenchyma. Four of six lesions with early enhancement on CT showed peripheral globular enhancement on early arterial-phase MRI. On multiphase spiral CT scans, small hemangiomas can show variable atypical enhancement features. In this situation, contrast-enhanced dynamic MRI is helpful for the diagnosis of hemangiomas

  9. Multi-slice spiral CT appearances of pulmonary infections after liver transplantation

    International Nuclear Information System (INIS)

    Xie Lixuan; Liu Shiyuan; Chen Yousan; Gao Xiaogang

    2009-01-01

    Objective: To investigate multi-slice spiral CT (MSCT) appearances of pulmonary infections after liver transplantation (LT) and the diagnostic values of MSCT. Methods: The clinical data and CT images of liver transplantation receptors were reviewed from 2001 August to 2007 June, the types, onset time and CT appearances of pulmonary infections were analyzed retrospectively. Chi square test was used for the statistics. Results: The incidence rate of pulmonary infections after LT was 32.9% (174/529), the mortality was 9.8% (17/174), The incidence of bacterial infection, fungus or associated fungus infection, and virus or associated virus infection were 17.2% (n=91), 14.7% (n=78)and 2.3% (n=12)respectively, the pulmonary infections were seen in 64.7%, 28.7% and 6.6% of patients 1 to 30 days, 31-90 days and after 90 days following LT. Consolidations (n=32), ground-glass opacities (n= 22), nodules (n=10), reticular or lineal opacities (n=4) were found in 45 patients who had CT examination, there were no statistic differences in incidence rate between bacterial infection and mycotic infection (P>0.05). Conclusion: Pulmonary bacterial and fungus infection are common after LT, and often present as the mixed infection, the high risk period for infection is within 30 days after LT, thoracic CT scan is very important for characterizing the pulmonary infections after LT. (authors)

  10. Morphological and functional diagnosis in the head and neck with multiplanar spiral CT; Morphologische und funktionelle Diagnostik der Kopf-Hals-Region mit Mehrzeilen-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Lell, M.; Baum, U.; Noemayr, A.; Greess, H.; Lenz, M.; Bautz, W. [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. fuer Diagnostische Radiologie; Koester, M. [Erlangen-Nuernberg Univ., Erlangen (Germany). Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenkranke

    1999-11-01

    Purpose: To evaluate the improvement of multislice-spiral CT in the assessment of head and neck tumors. Material and methods: 80 patients with suspected tumor in the head and neck region were examined with MSCT (Somatom Plus 4 VZ) after the administration of i.v. contrast material. Slice collimation was 4x1 mm with a pitch factor of 6. Additional multiplanar reformations were calculated in each case. Results: The specific anatomy and pathways of tumor spread is difficult to demonstrate in cross-sectional imaging. Tumor infiltration of the base of the skull or the palate could be depicted or excluded on coronal MPR, additional coronal scanning was not necessary. The detection of pathologic lymph nodes was improved with MPR in 7 patients. Discussion: The exact determination of tumor margins is mandatory for modern therapy concepts of limited surgery. High resolution datasets are basis for reformations in arbitrary planes, making additional coronal scanning not necessary. Functional imaging of the larynx and hypopharynx improve the diagnostic accuracy of CT, a short scantime is necessary to reduce motion artifacts. Conclusive assessment of tumor infiltration, lymphatic spread and functional alterations is improved with MSCT. (orig.) [German] Zielsetzung: Die Mehrzeilen-Spiral-CT (MSCT) bietet den Vorteil kurzer Untersuchungszeiten bei verbesserter Aufloesung in der Koerperlaengsachse (z-Richtung). Die daraus resultierenden Verbesserungen fuer die Bildgebung in der Kopf-Hals-Diagnostik sollen aufgezeigt werden. Material und Methoden: 80 Patienten mit Tumorverdacht im Kopf-Hals-Bereich wurden an einem MSCT (Somatom Plus 4 VZ) mit einer Schichtkollimation von 4x1 mm und pitch 6 nach i.v.-Kontrastmittelgabe untersucht. In allen Faellen wurden zusaetzlich zu den axialen Schnittbildern Sekundaerrekonstruktionen angefertigt. Ergebnisse: Die besonderen anatomischen Verhaeltnisse dieser Region sowie die Lage der bevorzugten Ausbreitungswege von Kopf-Hals-Tumoren koennen in

  11. Measurement of total lung capacity : a comparison of spiral CT and spirometry

    International Nuclear Information System (INIS)

    Chung, Kyung Il; Park, Kyung Ju; Lee, Eh Hyung; Yune, Heun Young; Suh, Jung Ho; Choe, Kyu Ok; Lim, Tae Hwan; Chung, In Hyuk

    1996-01-01

    To determine the potential of spiral CT as a functional imaging modality of the lung aside from its proven value in morphological depiction. Spiral CT scan was performed in ten normal female and nine normal male adults (mean age: 39, height: 163 cm, weight: 62 kg ) after single full breath-holding. Three dimensional lung images were reconstructed(minimal threshold value: -1,000HU, maximal threshold values: -150, 250, -350, -450 HU) to obtain total lung volume(TLV) on a histogram. Total lung volume measured by spiral CT was compared with TLV obtained by spirometry. Mean TLV measured by spirometry was 5.62L and TLV measured by CT at maximal threshold values of -150, -250, -350, and -450 HU was 5.53, 5.33, 5.15, and 4.98L, respectively. Mean absolute differences between the modalities of 0.17L(3%), 0.32L(5.6%), 0.48L(8.5%), 0.65L(11.5%) were statistically significant(p<0.001). Linear regression coefficients between the modalities were 0.99, 0.97, 095, and 0.94 and no statistically significant differences in accuracy of threshold levels in the estimation of lung volume(r=0.99, standard error=0.034L in all) were seen. TLV measured by spiral CT closely approximated that measured by spirometry. Spiral CT may be useful as a means of evaluating lung function

  12. Spiral CT scanning plan to generate accurate Fe models of the human femur

    International Nuclear Information System (INIS)

    Zannoni, C.; Testi, D.; Capello, A.

    1999-01-01

    In spiral computed tomography (CT), source rotation, patient translation, and data acquisition are continuously conducted. Settings of the detector collimation and the table increment affect the image quality in terms of spatial and contrast resolution. This study assessed and measured the efficacy of spiral CT in those applications where the accurate reconstruction of bone morphology is critical: custom made prosthesis design or three dimensional modelling of the mechanical behaviour of long bones. Results show that conventional CT grants the highest accuracy. Spiral CT with D=5 mm and P=1,5 in the regions where the morphology is more regular, slightly degrades the image quality but allows to acquire at comparable cost an higher number of images increasing the longitudinal resolution of the acquired data set. (author)

  13. The value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice

    International Nuclear Information System (INIS)

    Huang Zhi; Liu Zhang; Yang Chaoxiang; Lin Chengye; Zhang Li; Li Yuxiang; Ma Yunyan; Xiao Haisong; Lu Zhifeng; Wang Bo; Zhou Yunhong

    2009-01-01

    Objective: To approach the value of spiral CT thin imaging reconstruction in the diagnosis of obstructive jaundice in order to improve the correctness of the diagnosis. Methods: Analysis the cases' clinical manifestation and the CT images, who were diagnosed as obstructive jaundice by operation. All of cases had high-resolution computed tomograyhy scan. The thickness and the interval is 5mm, reconstructed the thickness and the interval to 1 mm and 1.5 mm, then send the images to the workstation and MRR were processed. Analysis the date with the pathology. Results: Spiral CT thin imaging reconstruction have 98% and 93% in the accuracy of location and characterization in the obstruction. Conclusion: The spiral CT thin imaging reconstruction is a good method to improve the accuracy of location and characterization in the obstructive jaundice. (authors)

  14. First results of spiral CT angiography in the evaluation of carotid artery stenosis

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Brossmann, J.; Grabener, M.; Voss, C.; Heller, M.

    1995-01-01

    To determine the value of spiral CT angiography in Maximum Intensity Projection (MIP)-technique for evaluation of carotid artery stenosis. A comparison of the MIP technique with intraarterial DSA was done in 24 patients with 40 stenoses. Quantification of stenosis was determined according to the NASCET study: mild (0-29%), moderate (30-69%), severe (70-99%) and occlusion (100%). Totally the correlation of spiral CT angiography with DSA was 80% (r=0.93; p=0.0001). In the moderate stenosis group (r=1; p=0.1573), severe stenosis group (r=0.89; p=0.002) and the occlusion group (r=1; p=0.0009) there was a good correlation with DSA. In the mild stenosis group (r=0.55; p=0.0704) correlation of spiral CT angiography with DSA was poor. Spiral CT angiography allows an excellent delineation of calcifications. Tandem lesions and collateral flow cannot be shown with spiral CT angiography. (orig./MG) [de

  15. Correlation between spiral CT features of pericolic infiltration and tumor angiogenesis in colorectal carcinoma

    International Nuclear Information System (INIS)

    Zhang Ruiping; Li Jianding

    2007-01-01

    Objective: To investigate the correlation of spiral CT (SCT) features with pathology, microvessel density (MVD), expression of vascular endothelial growth factor (VEGF), matrix metalloproteinase-2( MMP-2) in colorectal carcinoma. Methods: Forty patients with colorectal carcinoma confirmed by operation were examined by SCT. The resected tumor specimens were immunohistochemically stained for the expression of VEGF, MMP-2 and the calculation of MVD. Results: The accuracy of SCT in depicting the pericolic and wall infiltration was 92.5%. The metastasis rates of colorectal cancer with pericolic infiltration and wall infiltration were 75.0% and 33.3%, respectively, the differences were statistically significant between the two groups (P<0.05). The differences of CT enhancement value, MVD, expressions of VEGF and MMP-2 between the two groups were statistically significant (P<0.05). The enhancement degree of CT had a positive correlation with MVD (P<0.05). Conclusion: SCT is accurate for depicting pericolic and wall infiltration, pericolic infiltration in colorectal carcinoma indicates the tendency of metastasis. The enhancement degree of CT might be used to quantitatively evaluate the tumor angiogenesis, expressions of VEGF and MMP-2 and MVD are closely correlated with the infiltration of colorectal cancer. (authors)

  16. Paired inspiratory/expiratory spiral CT and continuous respiration cine CT in the diagnosis of tracheal instability

    International Nuclear Information System (INIS)

    Heussel, C.P.; Schreiber, W.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2001-01-01

    In tracheo- and bronchomalacia, localisation and determination of collapse is necessary for planning of surgical procedure. We compared inspiratory and expiratory spiral CT, cine CT, bronchoscopy, exemplary cine MR, and evaluated the clinical relevance. Twenty-nine patients (2 follow-ups; mean age 61 years, age range 27-85 years) with suspected or verified tracheal stenosis or collapse (post-tracheotomy: n=17; neoplasm: n=5; other: n=7) underwent paired breath-hold inspiratory and expiratory spiral CT. Forty-five additional cine CT were performed at 1-4 levels (mean 1.5) during continuous respiration (increment 100 ms) to clarify respiratory collapse. The tracheal cross-sectional diameters of both techniques were calculated. Comparison with bronchoscopy, follow-up, and influence upon therapy were evaluated retrospectively. Exemplary comparison with cine MR (8 frames/s) was done in 3 cases. In addition to bronchoscopy, further information concerning localisation, extent, collapse, stability of the tracheal wall, distal portions of the stenosis and extraluminal compressions were obtained. A significantly higher degree and more pathological collapses (>50%) were seen using cine CT (38%) compared with paired spiral CT (13%; degree: p<0.0001; number: p<0.001). The findings changed the further therapeutic procedure in 16 of 29 patients. Further stenoses were excluded and bronchoscopy was verified in another 13 of 29. Temporal resolution of cine CT and cine MR is sufficient; however, spatial resolution of cine MR is inferior. Paired inspiratory and expiratory spiral CT localises tracheal stenoses and demonstrates relevant extraluminal compression. Significantly improved evaluation of respiratory collapse and further information of localised tracheal instability is obtained by cine CT. Cine MR promises more functional information especially due to free choice of imaging plane. (orig.)

  17. Exact cone beam CT with a spiral scan

    International Nuclear Information System (INIS)

    Tam, K.C.; Samarasekera, S.; Sauer, F.

    1998-01-01

    A method is developed which makes it possible to scan and reconstruct an object with cone beam x-rays in a spiral scan path with area detectors much shorter than the length of the object. The method is mathematically exact. If only a region of interest of the object is to be imaged, a top circle scan at the top level of the region of interest and a bottom circle scan at the bottom level of the region of interest are added. The height of the detector is required to cover only the distance between adjacent turns in the spiral projected at the detector. To reconstruct the object, the Radon transform for each plane intersecting the object is computed from the totality of the cone beam data. This is achieved by suitably combining the cone beam data taken at different source positions on the scan path; the angular range of the cone beam data required at each source position can be determined easily with a mask which is the spiral scan path projected on the detector from the current source position. The spiral scan algorithm has been successfully validated with simulated cone beam data. (author)

  18. A computer-assisted method for 3D subtraction angiography based on spiral CT

    International Nuclear Information System (INIS)

    Englmeier, K.H.; Fink, U.; Haubner, M.; Becker, C.; Seemann, M.; Capeller, W.; Reiser, M.

    1996-01-01

    The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the disparities, which manifest as bright spots, the real shift of the two subsignals can be calculated. Translation of the corresponding image volume pairs to their correct positions improves the subtraction process. In all cases the size of the aneurysm and the abdominal organs could be better segmented and visualized. Application of the cepstrum filter and subtraction of the image volumes before, and after contrast medium injection completely removes the bony structures in the image data and results in superior visualization results. (orig./MG) [de

  19. Clinical value of 64-slice spiral CT for classification of femoral neck fracture

    International Nuclear Information System (INIS)

    Zhu Jiangtao; Gong Jianping; Cai Wu; Zhu Jianbing; Chen Guangqiang; Qian Minghui

    2011-01-01

    Objective: To evaluate the clinical application of 64-slice spiral CT for classification of femoral neck fracture. Methods: The survey was comprised of 46 patients with femoral neck fractures detected with plain radiographs and CT images. Cases were randomly presented in 2 formats: plain radiographs and CT. Garden classification was queried. Modification of garden classification (nondisplaced vs displaced) was taken to compare with plain radiographs and CT in the study. Results: The results of classification for plain radiographs were 2 cases of Garden Ⅰ, 10 cases of Ⅱ, 22 cases of Ⅲ, and 12 cases of Ⅳ. Those for CT were 1 cases of Garden Ⅰ, 4 cases of Ⅱ, 26 cases of Ⅲ, and 15 cases of Ⅳ. CT improved the accuracy of Garden Classification (P<0.05). Conclusion: Garden classification using CT images shows good conformation with results of surgery. 64-Slic CT is better plain radiographs for Garden classification of femoral neck fracture. (authors)

  20. Detection of hepatocellular carcinoma with multi-slice spiral CT by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-06-07

    Jun 7, 2010 ... spiral CT by using double-arterial phase and portal venous phase enhanced scanning: Effect of iodine concentration of contrast material. Jian-shou Zhou1, Yi Huan1*, Meng-qi Wei1 and Xin-qing Jiang2. 1Department of Radiology, Xijing Hospital, Fourth Military Medical University, Chang Le Western Road ...

  1. Spiral hydro-CT of the pancreas in the thin-slice method; Hydrospiral-CT des Pankreas in Duennschichttechnik

    Energy Technology Data Exchange (ETDEWEB)

    Richter, G.M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Simon, C. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)]|[Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Hoffmann, V. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); DeBernardinis, M. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Seelos, R. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Senninger, N. [Abt. Allgemeine Chirurgie, Chirurgische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. fuer Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-05-01

    In an open prospective study, 151 patients with a suspected pancreatic neoplasm based on clinical, laboratory or other imaging data were examined between May 94 and October 95. Our newly developed Hydro-CT methodology included intravenous injection of 40 mg N-butylscopolaminium bromide (Buscopan) for intestinal paralysis, gastric and duodenal wall distension by oral administration of an average of 1.5 l warm tap water, 30 RAO patient positioning, an individualized contrast injection technique as determined beforehand by time-to-peak measurement in the portal vein and thin-slice spiral CT (3 mm increment, 6 mm table feed and 3 mm secondary reconstruction). A detailed evaluation form was used to assess (1) tumor detection rate, (2) differentiation of malignant versus benign disease, (3) differential diagnosis, and (4) accuracy of assessment of resectability by identification of infiltration into adjacent organs and vessel structures relevant for resectability such as splenic, superior mesenteric, portal vein and celiac trunk, superior mesenteric, splenic and hepatic arteries. As the gold standard for positive tumor detection surgery and microscopic diagnosis were used, and for negative tumor detection an event-free survival of 6 months. Almost all examinations were well tolerated. In only 4% was on-site administration of a gastric tube required because of vomiting. In 2% of the patients a slight allergic reaction to be contrast medium was seen. The prevalence of a pancreatic neoplasm was 38%. In tumor detection Hydro-CT reached an overall accuracy of 97.4% with a sensitivity of 100% and a specificity of 95.9%. In the differentiation of benign versus malignant disease Hydro-CT reached an overall accuracy of 89.7% with a sensitivity of 92.5% and a specificity of 83.3%. The prevalence of a pancreatic carcinoma was 24%; 4% other malignant tumors were found (distal common bile duct carcinoma, cystadenocarcinoma). (orig./MG) [Deutsch] Von Mai 1994 bis Oktober 1995 wurden

  2. Spiral CT angiography of splanchnic artery aneurysms. Technique and results

    International Nuclear Information System (INIS)

    Squillaci, E.; Ciolfi, M.G.; Maspes, F.; Simonetti, G.

    1999-01-01

    The aneurysm of visceral vessel are characterized by few or no symptoms and the diagnosis is often occasional. The authors investigated the usefulness of CT angiography in the diagnosis and preoperative assessment in this conditions. In the experience of the authors CT angiography can replace digital subtraction angiography in the diagnosis and preoperative work-up of visceral vessel aneurysms. CT angiography was superior to digital angiography to the evaluation of the lesion exact dimensions in case with large thrombotic component and diffuse wall calcifications [it

  3. The findings and the role of axial CT imaging and 3D imaging of gastric lesion by spiral CT

    International Nuclear Information System (INIS)

    Lee, Dong Ho; Ko, Young Tae

    1996-01-01

    The purpose of this study is to assess the efficacy of axial CT imaging and 3D imaging by spiral CT in the detection and evaluation of gastric lesion. Seventy-seven patients with pathologically-proven gastric lesions underwent axial CT and 3D imaging by spiral CT. There were 49 cases of advanced gastric carcinoma(AGC), 21 of early gastric carcinoma (EGC), three of benign ulcers, three of leiomyomas, and one case of lymphoma. Spiral CT was performed with 3-mm collimation, 4.5mm/sec table feed, and 1-1.5-mm reconstruction interval after the ingestion of gas. 3D imaging was obtained using the SSD technique, and on analysis a grade was given(excellent, good, poor). Axial CT scan was performed with 5-mm collimation, 7mm/sec table feed, and 5-mm reconstruction interval after the ingestion of water. Among 49 cases of AGC, excellent 3D images were obtained in seven patients (14.3%), good 3D images in 30(61.2%), and poor 3D images in 12(24.5%). Among the 12 patients with poor images, the cancers were located at the pyloric antrum in eight cases, were AGC Borrmann type 4 in three cases, and EGC-mimicking lesion in one case. Using axial CT scan alone, Borrmann's classification based tumor morphology were accurately identified in 67.3% of cases, but using 3D imaging, the corresponding figure was 85.7%. In 33 cases receiving surgery, good correlation between axial CT scan and pathology occurred in 72.7% of T class, and 69.7% of N class. Among 21 cases of EGC, excellent 3D images were obtained in three patients (14.3%), good 3D images in 14 (66.7%), and poor 3D images in two (9.5%). The other two cases of EGC were not detected. By axial CT scan, no tumor was detected in four cases, and there were two doubtful cases. 3D images of three benign ulcers were excellent in one case and good in two. 3D images of three leiomyomas and one lymphoma were excellent. Combined axial CT imaging and 3D imaging by spiral CT has the potential to accurately diagnose gastric lesions other than AGC

  4. Radiation exposure from CT examinations in Japan.

    Science.gov (United States)

    Tsushima, Yoshito; Taketomi-Takahashi, Ayako; Takei, Hiroyuki; Otake, Hidenori; Endo, Keigo

    2010-11-02

    Computed tomography (CT) is the largest source of medical radiation exposure to the general population, and is considered a potential source of increased cancer risk. The aim of this study was to assess the current situation of CT use in Japan, and to investigate variations in radiation exposure in CT studies among institutions and scanners. Data-sheets were sent to all 126 hospitals and randomly selected 14 (15%) of 94 clinics in Gunma prefecture which had CT scanner(s). Data for patients undergoing CT during a single month (June 2008) were obtained, along with CT scan protocols for each institution surveyed. Age and sex specific patterns of CT examination, the variation in radiation exposure from CT examinations, and factors which were responsible for the variation in radiation exposure were determined. An estimated 235.4 patients per 1,000 population undergo CT examinations each year, and 50% of the patients were scanned in two or more anatomical locations in one CT session. There was a large variation in effective dose among hospitals surveyed, particularly in lower abdominal CT (range, 2.6-19.0 mSv). CT examinations of the chest and upper abdomen contributed to approximately 73.2% of the collective dose from all CT examinations. It was estimated that in Japan, approximately 29.9 million patients undergo CT annually, and the estimated annual collective effective dose in Japan was 277.4 *103 Sv person. The annual effective dose per capita for Japan was estimated to be 2.20 mSv. There was a very large variation in radiation exposure from CT among institutions surveyed. CT examinations of the chest and upper abdomen were the predominant contributors to the collective dose.

  5. Multi-slice spiral CT of aortocoronary grafts and internal mammary artery bypasses: Assessment of bypasses and their anastomoses

    International Nuclear Information System (INIS)

    Froehner, S.; Wagner, M.; Schmitt, R.; Christopoulos, G.; Coblenz, G.; Brunn, J.; Mueller, M.; Kerber, S.; Urbanski, P.

    2002-01-01

    Objective: To assess aortocoronary grafts and internal mammary artery bypasses by means of EKG-triggered contrast-enhanced multi-slice spiral CT, and to evaluate the diagnostic accuracy of this new imaging modality. Material and methods: 59 patients with up to 5 aortocoronary grafts and/or internal mammary artery bypasses per patient were examined with regard to bypass morphology, the free passage, and the proximal as well as the distal anastomoses using multi-slice computed tomography. Axial source images were calculated by means of retrospective triggering at different diastolic delay times, and were postprocessed in several planes with the multiplanar volume reconstruction (MPVR) software. Results: On the pre-condition that data sets were acquired at sinus rhythm and at a heart rate lower than 65/min, aortocoronary grafts and internal mammary artery bypasses could be depicted in adequate diagnostic quality in about 80% of all cases with contrast-enhanced multi-slice spiral CT. Both, the free passage of the bypasses as well as the morphology of the proximal anastomoses were sufficiently assessed with multiplanar volume reconstruction (MPVR), whereas the distal anastomoses couldn't be depicted sufficiently in 20% of all cases. Conclusion: As a non-invasive method, contrast-enhanced and ECG-triggered multi-slice spiral computed tomography has gained diagnostic potential for the accurate visualization of aortocoronary grafts and the internal mammary artery bypasses. (orig.) [de

  6. Three phase spiral liver Scanning

    International Nuclear Information System (INIS)

    Kanyanja, T.A.

    2006-01-01

    The ability to perform rapid back-to-back spiral acquisitions is an important recent technical advantage of spiral CT. this allows imaging of the upper abdomen (liver) during peak arterial enhancement (arterial phase) and during peak hepatic parenchymal enhancement (portal venous phase). Breatheld spiral CT has completely replaced dynamic incremental CT for evaluation of the liver. in selected patients with hyper vascular metastasis (hepatoma, neuroendocrine tumors, renal cell carcinoma, etc.) a biphasic examination is performed with one spiral acquisition obtained during the hepatic arterial phase and a second acquisition during the portal venous phase

  7. Intracranial CT angiography obtained from a cerebral CT perfusion examination

    NARCIS (Netherlands)

    Gratama van Andel, H. A. F.; Venema, H. W.; Majoie, C. B.; den Heeten, G. J.; Grimbergen, C. A.; Streekstra, G. J.

    2009-01-01

    CT perfusion (CTP) examinations of the brain are performed increasingly for the evaluation of cerebral blood flow in patients with stroke and vasospasm after subarachnoid hemorrhage. Of the same patient often also a CT angiography (CTA) examination is performed. This study investigates the

  8. Evaluation of 16 detector row spiral CT in diagnosing pulmonary embolism

    International Nuclear Information System (INIS)

    Yu Xiaokun; Li Lei

    2008-01-01

    Objective: To investigate the value of 16 detector row spiral CT in the diagnosis of pulmonary embolism(PE). Methods: Imaging data of 20 patients (plain 16 detector row spiral CT scanning plus enhanced scanning imaging) highly suspected of PE was retrospectively analyzed. Results: Among the 20 cases, embolism was showed in 13 patients on 16 detector row spiral CT pulmonary angiography (MSCTPA). 6 cases of the 13 PE's patients have masculine findings on plain MSCT scanning images. Localized tenuous lung markings, dilated pulmonary artery, 'mosaic' sign, pleural or pericardial effusion, local high attenuation centrally in the pulmonary arteries and lung infarction occurred respectively. Conclusion: MSCTPA may be an effective, simple and safe technique for the diagnosis of PE. It was a reliable means in defecting PE However, for the cases unfit for contrast media and cases only suitable for unenhanced CT because of nonspecific heart-pulmonary symptom, noticeable abnormal signs of plain MSCT scanning could suggest the occurrence of pulmonary embolism. (authors)

  9. Clinical application of the three-dimensional reconstruction of spiral CT pneumocolon

    International Nuclear Information System (INIS)

    Yu Shenping; Li Ziping; Xu Dasheng; Lin Erjian; Lin Peizhang; Xu Qiaolan

    2000-01-01

    Objective: To evaluate the clinical role of the 3 types of reconstruction of the spiral CT pneumocolon in the diagnosis of colon lesions. Methods: Three types of reconstruction with spiral CT pneumocolon including air cast imaging (ACI), CT virtual endoscopy (CTVE), and multiple planner reconstruction (MPR) in 34 patients with colorectal cancer or polyps were correlated with surgical pathology respectively. Results: Among the 34 patients, 30 was colorectal cancer and 6 was polyps (2 of which in the proximal lumen of 2 colon cancer). (1) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal cancer. 1) ACI: tumor patterns: coincide (n =22), anti-coincide (n = 8); tumor extension: coincide (n = 24), anti-coincide (n = 6); tumor size: coincide (n = 28), anti-coincide (n = 2). 2) CTVE: tumor patterns: coincide (n = 26), anti-coincide (n = 4); tumor extension: coincide (n = 25), anti-coincide ( n 5); tumor size: coincide (n = 23), anti-coincide (n = 7). 3) MPR: tumor patterns: coincide (n = 24), anti-coincide (n = 6); tumor extension: coincide (n = 30), anti-coincide (n = 0); tumor size: coincide (n = 26), anti-coincide (n = 4). (2) Comparison between the 3 types of the spiral CT pneumocolon reconstruction and pathology in colorectal polyps: the lesions were displayed in 4 (ACI) and in 6 (CTVE and MPR). Conclusion: (1) For the diagnosis of colorectal cancers: CTVE was the best means to display the tumor patterns, MPR most correct to judge the tumor extension, and ACI most suitable to measure the tumor size. (2) For the diagnosis of colorectal polyps, ACI can be used for oriented diagnosis, CTVE can well display the intra-luminal three-dimensional structure and can be used for characteristic diagnosis, MPR can be used for differential diagnosis

  10. Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience

    International Nuclear Information System (INIS)

    Wang, Q.; Qin, J.; He, B.; Zhou, Y.; Yang, J.-J.; Hou, X.-L.; Yang, X.-B.; Chen, J.-H.; Chen, Y.-D.

    2013-01-01

    Aim: To evaluate the feasibility of double prospectively electrocardiogram (ECG)-triggered high-pitch spiral acquisition mode (double high-pitch mode) for coronary computed tomography angiography (CTCA). Materials and methods: One hundred and forty-nine consecutive patients [40 women, 109 men; mean age 58.2 ± 9.2 years; sinus rhythm ≤70 beats/min (bpm) after pre-medication, body weight ≤100 kg] were enrolled for CTCA examinations using a dual-source CT system with 2 × 128 × 0.6 mm collimation, 0.28 s rotation time, and a pitch of 3.4. Double high-pitch mode was prospectively triggered first at 60% and later at 30% of the R–R interval within two cardiac cycles. Image quality was evaluated using a four-point scale (1 = excellent, 4 = non-assessable). Results: From 2085 coronary artery segments, 86.4% (1802/2085) were rated as having a score of 1, 12.3% (257/2085) as score of 2, 1.2% (26/2085) as score of 3, and none were rated as “non-assessable”. The average image quality score was 1.15 ± 0.26 on a per-segment basis. The effective dose was calculated by multiplying the coefficient factor of 0.028 by the dose–length product (DLP); the mean effective dose was 3.5 ± 0.8 mSv (range 1.7–7.6 mSv). The total dosage of contrast medium was 78.7 ± 2.9 ml. Conclusion: Double prospectively ECG-triggered high-pitch spiral acquisition mode provides good image quality with an average effective dose of less than 5 mSv in patients with a heart rate ≤70 bpm

  11. SPECT/spiral-CT hybrid imaging in unclear foci of increased bone metabolism: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Roemer, W.; Kuwert, T. [Nuklearmedizinische Klinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Beckmann, M.W. [Frauenklinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Forst, R. [Lehrstuhl fuer Orthopaedie mit Orthopaedischer Chirurgie, Friedrich-Alexander Univ. Erlangen/Nuernberg (Germany); Bautz, W. [Radiologisches Inst., Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany)

    2005-07-01

    In bone scintigraphy, the differentiation between degenerative processes and bone metastases is still difficult. Therefore, additional radiological studies are regularly needed after bone scintigraphy. The now introduced hybrid-cameras combining single-photon emission computed tomography (SPECT) and spiral-CT are unique in the sense that they offer the opportunity to correlate the functional information with morphology in one session. We herein present two patients in whom this technological setup allowed a definite diagnosis in scintigraphically unclear vertebral lesions. In a patient with breast cancer, hypermetabolic lesions were clearly correlated with osteolyses. In another patient with synovial carcinoma, spondylosis and spondylarthrosis caused focal tracer uptake in the lumbar spine. In addition to an improved diagnostic accuracy, SPECT/Spiral-CT will considerably abbreviate the diagnostic process. (orig.)

  12. Spiral CT aortography: an efficient technique for the diagnosis of traumatic aortic injury

    International Nuclear Information System (INIS)

    Wicky, S.; Capasso, P.; Meuli, R.; Schnyder, P.; Fischer, A.; Segesser, L. von

    1998-01-01

    The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients. (orig.)

  13. ACCURACY OF SPIRAL CT RENAL ANGIOGRAPHY OVER CONVENTIONAL ANGIOGRAPHY IN LIVING RENAL DONORS

    Directory of Open Access Journals (Sweden)

    Malle Vijaya Kumar

    2016-10-01

    Full Text Available BACKGROUND Potential donors for renal transplantation undergo an exhaustive pretty operative examination including medical assessment, laboratory testing and radiological imaging. The goal of imaging in these subjects is to delineate the kidneys and their vascular anatomy to determine if the subject is a suitable donor nephrectomy candidate and if so to assess which kidney maybe technically easier to transplant. This traditional imaging workup has consisted of two examinations, the IV Urogram (IVU and renal arteriography. MATERIALS AND METHODS Totally 18 healthy adults who were potential renal donors were taken for spiral CT angiography. The study was conducted in Viswabharathi Medical College, Penchikalapadu, Kurnool, Andhra Pradesh, between May 2015 and May 2016. RESULTS In the present study, supernumerary renal arteries were present in 7 cases (38.8% and consisted of one artery in 4 cases (11.1% two arteries in 3 cases (16.6%. Early branching of the main renal artery was seen in one case (2.7% venous anomaly in the form of retroaortic renal vein. Nonvascular abnormality noted in one case in the form of simple renal cyst in right upper pole (2.7%. Overall, CTA sensitivity, specificity and accuracy are 100%. In one case, axial sections could not find early branching, however, it was depicted in MIPS. CONCLUSION It is superior to conventional angiography in demonstrating accessory renal artery when it is arising from aorta immediately behind the main renal artery in anteroposterior direction and incidental findings like aortic calcifications, renal vein anomalies and renal cysts.

  14. Peripheral pulmonary arteries: identification at multi-slice spiral CT with 3D reconstruction

    International Nuclear Information System (INIS)

    Coche, Emmanuel; Pawlak, Sebastien; Dechambre, Stephane; Maldague, Baudouin

    2003-01-01

    Our objective was to analyze the peripheral pulmonary arteries using thin-collimation multi-slice spiral CT. Twenty consecutive patients underwent enhanced-spiral multi-slice CT using 1-mm collimation. Two observers analyzed the pulmonary arteries by consensus on a workstation. Each artery was identified on axial and 3D shaded-surface display reconstruction images. Each subsegmental artery was measured at a mediastinal window setting and compared with anatomical classifications. The location and branching of every subsegmental artery was recorded. The number of well-visualized sub-subsegmental arteries at a mediastinal window setting was compared with those visualized at a lung window setting. Of 800 subsegmental arteries, 769 (96%) were correctly visualized and 123 accessory subsegmental arteries were identified using the mediastinal window setting. One thousand ninety-two of 2019 sub-subsegmental arteries (54%) identified using the lung window setting were correctly visualized using the mediastinal window setting. Enhanced multi-slice spiral CT with thin collimation can be used to analyze precisely the subsegmental pulmonary arteries and may identify even more distal pulmonary arteries. (orig.)

  15. Spiral CT in kidney: assumption of renal function by objective evaluation of renal cortical enhancement

    International Nuclear Information System (INIS)

    Choi, Bo Yoon; Lee, Jong Seok; Lee, Joon Woo; Myung, Jae Sung; Sim, Jung Suk; Seong, Chang Kyu; Kim, Seung Hyup; Choi, Guk Myeong; Chi, Seong Whi

    2000-01-01

    To correlate the degree of renal cortical enhancement, objectively evaluated by means of spiral CT with the serum level of creatinine, and to determine the extent to which this degree of enhancement may be used to detect renal parenchymal disease. Eighty patients (M:F = 50:30; age + 25-19, (mean 53) years) with available serum level of creatinine who underwent spiral CT between September and October 1999 were included in this study. In fifty patients the findings suggested hepatic or biliary diseases such as hepatoma, biliary cancer, or stone, while in thirty, renal diseases such as cyst, hematoma, or stone appeared to be present. Spiral CT imaging of the cortical phase was obtained at 30-40 seconds after the injection of 120 ml of non-ionic media at a rate of 3 ml/sec. The degree of renal cortical enhancement was calculated by dividing the CT attenuation number of renal cortex at the level of the renal hilum by the CT attenuation number of aorta at the same level. The degree of renal cortical enhancement was compared with the serum level of creatinine, and the degree of renal cortical enhancement in renal parenchymal disease with that of the normal group. Among eighty patients there were five with renal parenchymal disease and 75 with normal renal function. The ratio of the CT attenuation number of renal cortex to that of aorta at the level of the renal hilum ranged between 0.49 and 0.99 (mean, 0.79; standard deviation, 0.15). while the serum level of creatinine ranged between 0.6 and 3.2 mg/dl. There was significant correlation (coefficient of -0.346) and a statistically significant probability of 0.002 between the ratio of the CT attenuation numbers and the serum level of creatinine. There was a significant difference (statistically significant probability of less than 0.01) between those with renal parenchymal disease and the normal group. The use of spiral CT to measure the degree of renal cortical enhancement provides not only an effective index for

  16. Pulmonary spheral tuberculosis: features and clinical significance of spiral dynamic CT

    International Nuclear Information System (INIS)

    Xie Ruming; Ma Daqing; Li Tieyi; Chen Yi; Lu Fudong; Zhou Xinhua

    2001-01-01

    Objective: To assess the features and clinical significance of spiral dynamic CT in patients with pulmonary spheral tuberculosis. Methods: The 54 foci in 42 patients with pulmonary spheral tuberculosis were studied. Thin-sections at 2 mm thickness and 2 mm interval through the nodular center were obtained before and after administration of contrast material. Results: In 54 pulmonary spheral tuberculosis, maximum enhanced CT value in 51 (94.4%, 51/54) foci was less than 20 HU, and more than 20 HU in the other 3(5.6%, 3/54) foci. 27(50.0%, 27/54) foci showed no any enhancement, 24, (44%, 24/54) foci showed capsular enhancement, 1(1.9%, 1/54) focus showed peripheral enhancement and 2(3.7%, 2/54) foci showed extensive enhancement. The accuracy of the correct diagnosis was 25.9% in terms of plain CT and 94.4% in terms of enhanced CT scanning. The difference was significant (x 2 = 50.1, P < 0.05). The curative effect of extensive enhanced foci and peripheral enhanced foci was optimal, capsular enhanced foci was second, and non-enhanced foci was barely satisfactory. Conclusion: Spiral dynamic CT technique may improve the accuracy of diagnosing pulmonary spheral tuberculosis. No enhancement and/or capsular enhancement were suggestive of tuberculosis. The enhancing character of foci might contribute to assess the curative effect of anti-tuberculosis

  17. Noninvasive diagnosis of suspected severe pulmonary embolism. Trans-esophageal echocardiography vs spiral CT

    International Nuclear Information System (INIS)

    Pruszczyk, P.; Torbicki, A.; Pacho, R.

    1998-01-01

    Patients with pulmonary embolism (PE) and echocardiographic signs of right ventricular over-lead have worse prognosis and may be require aggressive therapy. Unequivocal confirmation of PE is required before thrombolysis or embolectomy. This study compares the value of trans-esophageal echocardiography (TEE) and spiral CT (sCT) in direct visualization of pulmonary artery thrombo-emboli in patients with suspected PE and echocardiographic signs of right ventricular over-lead. Because of high prevalence of bilateral central pulmonary thrombo-emboli in patients with hemo-dynamically significant PE, both sCT and TEE allow its definitive confirmation in most cases. Thrombi reported by sCT distally to lobar arteries should be interpreted with caution. (author)

  18. Spiral CT biliary virtual endoscopy: preliminary clinical applications in the detection of biliary calculus

    International Nuclear Information System (INIS)

    Xiong Minghui; Wang Dong; Song Yunlong; Zhang Wanshi; Xu Jiaxing

    2000-01-01

    Objective: To evaluate imaging features and clinical value of CT biliary virtual endoscopy in the detection of biliary calculus. Methods: Eighteen patients with biliary calculi underwent volume scanning using spiral CT (Hispeed Advantage CT/i GE ). All data were transferred to computer workstation, and CT biliary virtual endoscopy images with pseudocolor encoding were generated from the volumetric data using the Navigator Smooth soft-ware. All cases were proved by ultrasound, axial CT or operation. Results: Among 18 cases, gallstones were found 8 in cases, common bile duct stones in 2 cases, gallstones and bile duct stones in 6 cases. The stones were 0.3-3.2 cm in size. CT biliary virtual endoscopy correctly demonstrated the surface details of stones which were viewed from extra- or intraluminal orientation in a 3D fashion. The findings were consistent with those of US, CT or operation. Conclusion: The CT virtual biliary endoscopy is a further development of virtual endoscopy for observing biliary calculus from intra- and extra-luminal views and providing three dimensional information of stone

  19. Skeletal and total body volumes of human fetuses: assessment of reference data by spiral CT

    International Nuclear Information System (INIS)

    Braillon, Pierre M.; Buenerd, Annie; Bouvier, Raymonde; Lapillonne, Alexandre

    2002-01-01

    Objective: To define reference data for skeletal and total body volumes of normal human fetuses. Materials and methods: Spiral CT was used to assess the skeletal and total body volumes of 31 normal human stillborn infants with gestational age (GA) and body weight (BW) ranging from 14 to 41.5 weeks and 22 to 3,760 g, respectively. CT scans (slice thickness 2.7 mm, pitch 0.7) were performed within the first 24 h after delivery. Precise bone and soft-tissue windows were defined from analysis of the density along the diaphysis of the fetal long bones and from the measurement of a phantom that mimics soft tissues. Lengths and volumes were obtained from 3D reconstructions. The femur lengths measured from CT images (FLct) were compared with those provided by US studies (FLus). Results: Significant correlations (r>0.9) were found between BW, measured volumes of the entire skeleton or head, long-bone lengths, biparietal diameter and GA. Strong linear correlations (r>0.98) were observed between FLct and FLus. Conclusions: Skeletal and total body volume values obtained using spiral CT were significantly correlated with fetal biometric measurements. These data could complement those obtained in obstetric investigations with US. (orig.)

  20. Diagnostic value of multi-slice spiral CT for atlantoaxial spine injuries in children

    International Nuclear Information System (INIS)

    Xia Chengde; Qin Hongwei; Li Junhong

    2009-01-01

    Objective: To evaluate the diagnostic value of multi-slice spiral CT (MSCT) for the atlantoaxial spine injuries in children. Methods: The CT findings of 21 cases with the atlantoaxial spine injuries in children were reviewed retrospectively. Results: Fractures of dens occurred in 4 cases, isolated atlantoaxial dislocation in 15 cases, subluxation of the C2/3 right vertebra facet in 1 and atlanto-occipital subluxation in 1. CT diagnosis was correct in all cases. And plain film diagnosis was correct ia 13. Conclusion: MSCT could clearly demonstrate the fractures and dislocations of the atlantoaxial spine injuries in children and correctly determine the type of the atlantoaxial spine injuries in children, MSCT is the modality of choice in diagnosis of the atlantoaxial spine injuries in children and should be performed routinely. (authors)

  1. Tilted plane Feldkamp type reconstruction algorithm for spiral cone beam CT

    International Nuclear Information System (INIS)

    Yan Ming; Zhang Cishen

    2005-01-01

    An approximate image reconstruction method for spiral cone beam computed tomography (CT), called tilted plane Feldkamp type reconstruction algorithm (TPFR), is presented in this paper, which extends Feldkamp cone beam reconstruction algorithm to deal with its inaccuracy and artifact problems caused by large cone angle. This is done by tilting the reconstructing planes to minimize the cone angle and optimally fit the spiral segment of the source. The tilted plane image reconstruction requires reforming the three-dimensional projection data set for the tilted plane and application of Feldkamp algorithm to the reformed data set. Analytical and computational results can show that the image reconstruction performance of the proposed TPFR algorithm is superior to that of the Feldkamp reconstruction algorithm in the image quality, volume coverage speed, maximum achievable pitch value, and slice sensitivity profiles. Moreover, it provides more accurate image reconstruction than the existing two-dimensional reconstruction algorithms

  2. Ancillary lung parenchymal findings at spiral CT scanning in pulmonary embolism. Relationship to chest sonography

    International Nuclear Information System (INIS)

    Reissig, Angelika; Heyne, Jens-Peter; Kroegel, Claus

    2004-01-01

    Introduction/objective: The aim of the study was to compare findings of transthoracic sonography (TS) and of spiral computed tomography (sCT) in patients with suspected pulmonary embolism (PE). Methods and patients: Peripheral parenchymal and pleural findings of TS and sCT were compared in 62 patients (25 females, 37 males; mean age 62.2 years) with suspected PE. Results: In 39 patients PE was established, of whose pleura-based lesions could be detected by TS in 30 patients and by sCT in 31 patients. Whilst in three of the patients parenchymal lesions were exclusively detected by sonography, no peripheral abnormalities could be discovered with either technique in five patients. Among the nine patients lacking peripheral abnormalities on sonography, four revealed peripheral lesions in sCT. In 23 patients without PE, peripheral consolidations at CT were detected in six patients whereas two showed lesions on TS. With respect to the appearance, pleura-based wedge-shaped consolidations were the main parenchymal alterations (82.4% at TS, 66.1% at sCT) as compared with non-wedge-shaped consolidations (17.6% at TS, 33.9% at sCT). Peripheral lesions were located preferentially within the lower lobes. In addition, both localised and basal pleural effusion associated with PE could be demonstrated in 58.9% at TS and in 23.1% by sCT. Discussions and conclusion: The study shows that in PE parenchymal and pleural changes are detectable by TS and sCT. If parenchymal findings are present at sCT, peripheral PE should be considered, even in the absence of directly visible emboli

  3. Differential diagnosis of gallbladder wall thickening by two phase spiral CT : gallbladder carcinoma versus cholicystitis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sun; Cho, Soon Gu; Kim, Mi Young; Woo, Je Hong; Shin, Seok Hwan; Lee, Kykung Hee; Suh, Chang Hae [Inha Univ. College of Medicine, Inchon (Korea, Republic of)

    2001-04-01

    To determine whether an analysis of two-phase CT features provides a sound basis for differential diagnosis between gallbladder carcinoma and cholecystitis. We reviewed a total of 89 cases of gallbladder carcinoma (n=35) or cholecystitis (n=54) in patients who had undergone two-phase spiral CT. For this, a GE Highspeed Advantage scanner (GE Medical Systems, Milwaukee, U . S . A .) was used. A total of 120ml of contrast material was injected at a rate of 2-3 ml/sec. Arterial and venous phase scans were obtained 35 and 65 seconds, respectively, after the initiation of contrast infusion. All cases of gallbladder carcinoma and 468 of cholecystitis (of a total of 482) were confirmed by histopathology. We reviewed the two phase spiral CT features, analyzing and assessing thickness of the lesion, the enhancement pattern seen during the arterial and the venous phase, invasion of liver, pericholecystic fat infiltration, dilatation of intrahepatic ducts, and other associated findings. Mean wall thickness was 12.6 mm in the gallbladder carcinoma group, and 7.2 mm in the cholecystitis group. The common enhancement patterns seen in gallbladder carcinoma were 1) a highly enhanced thick inner wall layer during the arterial phase which became iso attenuated with adjacent liver parenchyma during the venous phase (16/35; 45.7%) and 2) highly enhanced thick inner wall layer during both the arterial and venous phase (8/35; 22.9%). The most common enhancement pattern in cholecystitis cases was an iso attenuated thin inner wall layer during both the arterial and the venous phase (44/54; 81.5%). Findings of intrahepatic mass formation by direct invasion (9/35), lymph node enlargement (12/35), and metastasis to other organs (7/35) occurred only in cases of gallbladder carcinoma (18/35, 51.4%) than of cholecystitis (10/54, 18.5%). The incidence of pericholecystic fat infiltration and fluid collection was not significantly different between the gallbladder cancer and cholecystitis groups

  4. Post-mortem CT examination - own experiences

    International Nuclear Information System (INIS)

    Urbanik, A.; Chrzan, R.; Wozniak, K.; Moskala, A.

    2009-01-01

    The aim of the work was to present the possibilities and usefulness of the post - mortem CT examination in the evaluation of human corpses for the purposes of the forensic medicine. The examinations were performed with the use of the multidetector-row CT Somatom 16 (Siemens) unit, and involved 32 human corpses of people who died of unnatural causes (various causes, mostly injuries). CT examination made it possible to highlight the changes in the osseous system (skeletal system), parenchymatous organs (parenchymal organs, solid organs) and in the soft tissues, in every case. The CT images were useful in directing the performance of the traditional autopsy. When comparing the results of the virtual and the traditional autopsy, a high correlation of the results was affirmed. (authors)

  5. Study on application of spiral CT perfusion technology in the diagnosis of acute pancreatitis

    Directory of Open Access Journals (Sweden)

    Xiao-Sen Zhou

    2017-06-01

    Full Text Available Objective: To explore the application value of spiral CT perfusion technology in the diagnosis of acute pancreatitis (AP. Methods: A total of 78 patients with AP who were admitted in our hospital from September, 2014 to September, 2016 were included in the study. The velocity method was used to detect S-Amy and U-Amy. The emulsion enhancement velocity scattering turbidimetry was used to detect CRP. ELISA was used to detect D-D. The patients in the control group were performed with abdomen CT, while AP patients were performed with 64 slice spiral CT. The most integrated layer of pancreas display was regarded as the perfusion weighted imaging scanning layer, and CT perfusion scanning was performed. BF, BV, MTT, and PS were calculated. Results: S-Amy, U-Amy, CRP, and D-D in AP patients were significantly higher than those in the control group. With the disease progression, S-Amy and U-Amy were significantly reduced, while CRP and D-D were significantly elevated. BF and BV in AP patients were significantly lower than those in the control group, and those in SAP patients were significantly lower than those in MAP patients. With the elevation of CT grading, BF and BV were significantly reduced, while the comparison of MTT and PS among the various grading was not statistically significant. Conclusions: The pancreas perfusion in AP patients is in a low perfusion state. BF and BV are negatively correlated with the severity degree of AP, which can predict the prognosis. BF and BV in combined with the serum S-Amy, U-Amy, CRP, and D-D can provide a forceful evidence for the diagnosis, treatment, and condition evaluation of AP.

  6. [Clinical application of computer assisted technology based spiral CT scan for locating impacted tooth].

    Science.gov (United States)

    Zhang, Xing; Zhang, Jie-mei; Chen, Song-ling; Chen, Jian-ling

    2009-10-01

    To evaluate clinical value of computer assisted technology for locating the impacted tooth. Thirty-five patients with impacted tooth were received spiral CT scan. The DICOM data were processed by Simplant software for locating the impacted tooth. The reconstruction images clearly showed detail of the impacted teeth, including 3D surface image, eruption orientation, buccal and lingual location, medial and distal location and relationship with dentition and circumambient anatomic structure. The computer assisted technology can localize the impacted tooth precisely and provide valuable information for clinical treatment.

  7. The Role of Spiral Multidetector Dynamic CT in the Study of Williams-Campbell Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Scioscio, V. di; Zompatori, M.; Mistura, I.; Montanari, P.; Santilli, L.; Luccaroni, R.; Sverzellati, N. [Medical Univ. of Bologna, S. Orsola-Malpighi Policlinic (Italy). Dept. of Radiology

    2006-10-15

    Williams-Campbell syndrome is a cystic bronchiectatic disease secondary to deficiency or defect of cartilaginous plates in the wall of the airways. In the literature, two main forms are suggested: congenital and acquired (post-infectious). The most frequent symptoms are represented by recurrent pulmonary infections from childhood. Multislice spiral dynamic CT has a major role in the study of cystic pulmonary disease and in differentiating Williams-Campbell syndrome from the other causes of cystic bronchiectasis, in which even lung function tests can give deceptive results.

  8. Multi-slice spiral CT diagnosis of ovarian malignancy: report of 61 cases

    International Nuclear Information System (INIS)

    Wu Qiaoxiong; Chen Hong; Xu Maosheng

    2011-01-01

    Objective: To determine the value of multi-slice spiral CT (MSCT) for diagnosing ovarian malignancy. Methods: CT scans of 61 patients with pathologically proven ovarian malignancy were reviewed to assess the imaging appearances and accuracy of diagnosis. Results: MSCT demonstrated clearly the imaging features of all 61 cases of ovarian malignancy. 53 cases were correctly diangosed by MSCT before surgery with accuracy rate of 86.9%. The tumors included serous cystadenocarcinoma (35, 66%), mucinous cystadenocarcinoma (15, 28%), serous-mucinous cystadenocarcinoma (1, 1.8%), endometrioid carcinoma (3, 5.7%), embryonal carcinoma (2, 3.8%), and immature teratoma (5, 9.4%). Conclusion: MSCT displays the imaging features of ovarian malignancy cleary, thus enabling accurate diagnosis. It can provide comprehensive information for treatment planning and prognosis. (authors)

  9. The value of multislice spiral CT in the pre-operative diagnosis of cleft palate

    International Nuclear Information System (INIS)

    Tang Guangxi; Sun Lianfen; Zhang Xiaolin; Yu Chengxin; Lu Ji; Wang Xiaopeng; Li Liya; Yang Cheng; Wang Jun; Tian Yiqing

    2004-01-01

    Objective: To evaluate the practical value of multislice spiral CT (MSCT) in the preoperative diagnosis of cleft palate. Methods: Twenty patients with cleft palate were examined by using thin-slice (1.25 mm/4i) axial MSCT scanning and CT virtual endoscope (CTVE) imaging before and after operations. The cleft of each lesion was measured in the primary axial images. Results: Of the 20 cases, soft-and-hard cleft palate (grade II) was detected in 10 cases, with the clefts of soft palate between 1.5 cm and 2.2 cm, and the clefts of soft-and-hard palate between 1.2 cm and 2.0 cm. The right utter cleft palates were found in 3 cases with the clefts of soft palate between 2.0 cm and 2.5 cm, the clefts of soft-and-hard palate between 2.0 cm and 2.4 cm, and the clefts of hard palate between 1.8 cm and 2.2 cm. The left utter cleft palates (grade III) were found in 5 cases with the clefts of soft palate between 1.2 cm and 1.8 cm, the clefts of soft-and-hard palate between 0.9 cm and 2.0 cm, and the clefts of hard palate between 0.9 cm and 1.8 cm. The bilateral utter cleft palates (grade III) were detected in 2 cases with the clefts of soft palate between 2.1 cm and 2.3 cm, the clefts of soft-and-hard palate between 1.8 cm and 2.0 cm, and the clefts of hard palate between 1.9 cm and 2.3 cm. Conclusion: MSCT could excellently display the shape of all lesions before operation, especially the splitting degree of hard cleft palates in the axial images. Accurate measurements could be done for the cleft of different lesions in MSCT images. CTVE could clearly and directly show the shape of the lesion's interior surface. The pre-operative and post-operative images of each case could be perfectly compared by the combination of MSCT and CTVE

  10. Use of spiral CT in demonstrating early carcinoma of the stomach - I stage

    International Nuclear Information System (INIS)

    Pomakov, P.

    2009-01-01

    Full text: The aim of this lecture is to provide practical information about the methodology and technique of spiral computed tomography, which provide maximum diagnostic efficiency in early gastric cancer - I stage, and to present the semiotics of CT images seen in early gastric cancer stage I - a own and literature data. Methodology of the study covers optimal drug muscle relaxation of the abdominal wall by injection of 2 sg buskolizin intravenous; maximum distension of the stomach lumen by ingestion of 3 effervescent disintegrated tablets Vit. C with 1-2 sips of water, necessarily using of non-ionic contrast media - 100 ml / 300 mg iodine / 1 ml liquid bolus introduced for 30 seconds. Start scanning - 30 seconds of the start of injection - to visualize the arterial phase, use of slices with a thickness of 3 mm and 2 mm interval; exponential data 120 kV, 160 mAc. Earlier form of gastric cancer have to be presented by 5 CT image: unequal unsmooth, scallop or polycyclic contours of the lining, thinning the complete disappearance of the lining; undulating thickening of the lining; nodal formation like a polyp on a broad basis with a 2-5 mm, double contour of the lining - like a wave. These amendments are localized only in a limited segment of the gastric mucosa. Spiral CT is an effective diagnostic performance in gastric cancer, including the early stage I of cancer development. This is realized only by using the specific methodology of the study as well as good knowledge of the CT images semiology for carcinoma, localized only within a certain perimeter of the stomach lining

  11. Standardized CT examination of the multitraumatized patient

    Energy Technology Data Exchange (ETDEWEB)

    Leidner, B. [Department of Diagnostic Radiology, Oskarshamn Hospital (Sweden)]|[Department of Diagnostic Radiology, Huddinge University Hospital (Sweden); Adiels, M. [Department of Diagnostic Radiology, Oskarshamn Hospital (Sweden); Aspelin, P. [Department of Diagnostic Radiology, Huddinge University Hospital (Sweden); Gullstrand, P.; Wallen, S. [Department of Surgery, Oskarshamn Hospital (Sweden)

    1998-12-01

    The aim of this study was to develop a standardized non-helical-CT protocol including head, body and proximal extremities in order to achieve a good time efficiency and diagnostic accuracy in the initial radiological evaluation of the multitraumatized patient. A total of 111 circulatory stable blunt trauma patients, brought in to a trauma level II-III hospital, were examined according to a standardized CT protocol. After examining the head with contiguous 10-mm slices without IV contrast medium injection, the trunk was examined with 10-mm slices every 30 mm through thorax-abdomen-pelvis with IV contrast medium enhancement (occasionally modified). All data in the medical reports were collected and used as ``end-point``, and the outcome of the CT examination was compared with this final diagnosis. Mean examination time was 20 min (range 12-32 min). In total, 55 head injuries, 89 thoracic injuries, 27 abdominal/pelvic injuries and 62 fractures were found. Computed tomography correctly identified the injuries, except one brain stem injury, one contusion/rupture of the heart, one hepatic injury, two intestinal injuries, eight vertebral injuries and one joint dislocation. A standardized non-helical-CT examination of the head and body may be achieved in 20 min. Its diagnostic accuracy was high, except for vertebral column injuries, which is why we recommend it as the method of choice for initial radiological examination of multitraumatized patients. When available, helical scanning would improve both examination speed and accuracy. (orig.) With 6 figs., 40 refs.

  12. Spiral CT features of abdomen after whipple's operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. H.; Lee, K. Y.; Shin, K. H.; Jung, M. H.; Park, C. M.; Cha, I. H. [Korea Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-04-01

    To assess the CT features of postoperative anatomical changes, surgical complications, and patterns of tumor recurrence after Whipple's operation. 42 spiral CT scans of 31 patients who had undergone Whipple's operation were retrospectively reviewed. Postoperative diagnoses were distal CBD cancer in 13 patients, cancer of the ampulla of Vater in ten, cancer of the head of the pancreas in seven, and microcystic cystadenocarcinoma of the pancreas in one. Time intervals between surgery and CT ranged from 1 week to 5 years. CT features of postoperative anastomotic changes, surgical complications, and patterns of tumor recurrence were analyzed. Gastro- or duodeno-jejunal anastomosis was seen in 32 CT scans(74%), pancreaticojejunostomy in 27(64%), and choledochojejunostomy in 24(57%). Pneumobilia was seen in ten patients(34%). Abnormal fluid collections in the peripancreatic and perihepatic space were demonstrated in two patients who underwent CT scans within 3 weeks after operation. Other complications included wound abscess(n=2), and portal vein occlusion(n=1). The most common site of metastasis was the lymph node(n=8)(retroperitoneal:n=5; mesentery root:n=4; and celiac:n=2), followed by the liver(n=6), peritoneum(n=3), adrenal gland(n=2), and afferent loop(n=1). In three cases, there was local recurrence in the pancreatic bed. To reduce possible diagnostic errors during CT interpretation, a Knowledge of normal postoperative anatomy, common complications, and patterns of disease recurrence following Whipple's operation is important.

  13. Evaluation of an exposed-radiation dose on a dual-source cardiac computed tomography examination with a prospective electrocardiogram-gated fast dual spiral scan

    International Nuclear Information System (INIS)

    Matsubara, Kosuke; Koshida, Kichiro; Koshida, Haruka; Sakuta, Keita; Hayashi, Hiroyuki; Takata, Tadanori; Horii, Junsei; Kawai, Keiichi; Yamamoto, Tomoyuki

    2012-01-01

    We evaluated exposed-radiation doses on dual-source cardiac computed tomography (CT) examinations with prospective electrocardiogram (ECG)-gated fast dual spiral scans. After placing dosimeters at locations corresponding to each of the thoracic organs, prospective ECG-gated fast dual spirals and retrospective ECG-gated dual spiral scans were performed to measure the absorbed dose of each organ. In the prospective ECG-gated fast dual spiral scans, the average absorbed doses were 5.03 mGy for the breast, 9.96 mGy for the heart, 6.60 mGy for the lung, 6.48 mGy for the bone marrow, 9.73 mGy for the thymus, and 4.58 mGy for the skin. These values were about 5% of the absorbed doses for the retrospective ECG-gated dual spiral scan. However, the absorbed dose differed greatly at each scan, especially in the external organs such as the breast. For effective and safe use of the prospective ECG-gated fast dual spiral scan, it is necessary to understand these characteristics sufficiently. (author)

  14. [Evaluation of the blood flow in common hepatic tumors by multi-slice spiral CT whole-liver perfusion imaging].

    Science.gov (United States)

    Li, Mengdi; Chen, Yong; Gao, Zhiling; Zhu, Kai; Yin, Xin

    2015-12-01

    To study the characteristics of blood flow in common hepatic tumors by 256-slice spiral CT whole-liver perfusion imaging. Seventy-one patients with hepatic tumors were examined retrospectively by 256-slice spiral CT whole-liver perfusion. Among them, twenty-seven cases were of primary hepatic cancer, twenty-four cases of hepatic hemangioma, and twenty cases of hepatic metastases.Regions of interest (ROIs) were placed in the tumor parenchyma (Area A), peritumoral hepatic parenchyma (Area B), and normal hepatic parenchyma (Area C), respectively. The time density curves (TDC) were drawn, and perfusion parameters including hepatic arterial perfusion(HAP), portal venous perfusion(PVP), total liver perfusion(TLP) and hepatic erfusion index(HPI) were obtained. The values of ROIs were measured, and the perfusion parameters in the areas A, B, C of different hepatic tumors were statistically analyzed. The values of HAP, PVP, HPI in the tumor parenchyma of primary hepatic carcinoma were (20.00 ± 11.41)ml · min(-1) · 100 ml(-1,) (32.31 ± 21.06)ml · min(-1) · 100 ml(-1,) (52.31 ± 30.55)ml · min(-1) · 100 ml(-1,) and (39.67 ± 11.19)%, showing significant difference as compared with those in peritumoral hepatic parenchyma and in normal hepatic parenchyma(PHAP, TLP, and HPI in the tumor parenchyma of hepatic hemangioma were (40.39 ± 29.23)ml · min(-1) · 100 ml(-1,) (132.72 ± 132.65) ml · min(-1) · 100 ml(-1,) and (35.51 ± 15.12)%, were significantly different as compared with those in the peritumoral hepatic parenchyma and in normal hepatic parenchyma(PHAP, PVP, HPI in the tumor parenchyma of hepatic metastases were (17.43 ± 12.27)ml · min(-1) · 100 ml(-1,) (36.19 ± 34.99) ml · min(-1) · 100 ml(-1,) and (37.86 ± 14.49)%, significantly different as compared normal hepatic parenchyma (PHAP, PVP, and TLP of tumor tissue and the PVP and HPI of peritumoral tissue in different hepatic tumors were statistically significantly different (P<0.05). The multi

  15. The usefulness of levin tube inserted drip infusion spiral CT: comparison with conventional method in subtotal gastrectomy patients

    International Nuclear Information System (INIS)

    Park, Young Jin; Kim, Young Hwan; Yoon, Jung Hee; Cha, Soon Joo; Kim, Jeong Sook; Kim, Sung Rok; Hur, Gham; Rhim, Hyun Chul

    1998-01-01

    The purpose of this study is to access the usefulness of newly designed Levin tube inserted drip infusion spiral CT for the evaluation of remnant stomach and anastomosis site in patients who have undergone subtotal gastrectomy for stomach cancer. A new technique named Levin tube inserted drip infusion spiral CT was used to prospectively study 23 patients. A 16Fr Levin tube was inserted into the remnant stomach; 500 ml of tap water was drip infused just before CT scanning and an additional 500 ml of water was infused during IV contrast injection. Water was infused by gravity, using a water bottle suspended at a height of 90 cm (Group A). The 31 patients who underwent conventional spiral CT scanning immediately after the divided ingestion of 900 ml diluted gastrografin were selected as a control group (Group B). The anatomic delineation of the anastomosis site was graded by two radiologists as excellent (3), good(2), fair (1) or poor (0). To evaluate the degree of distension, the maximal diameters of remnant stomach and the anastomosis site, and the thickness of the stomach wall, were also measured. In patients who had undergone subtobal gastrectomy, Levin tube inserted drip infusion spiral CT showed excellent anatomic delineation of the site of anastomosis and remnant stomach. We found that because it increases the distension of remnant stomach and the anastomosis site, this technique is effective for the evaluation of postoperative stomach. (author). 10 refs., 2 tabs., 3 figs

  16. Detection of lung nodules with low-dose spiral CT: comparison with conventional dose CT

    International Nuclear Information System (INIS)

    Zhu Tianzhao; Tang Guangjian; Jiang Xuexiang

    2004-01-01

    Objective: To investigate the effect of reducing scan dose on the lung nodules detection rate by scanning a lung nodule model at low dose and conventional dose. Methods: The lung and the thoracic cage were simulated by using a cyst filled with water surrounded by a roll bandage. Flour, butter, and paraffin wax were mixed together by a certain ratio to simulate lung nodules of 10 mm and 5 mm in diameter with the CT values ranging from -10 to 50 HU. Conventional-dose scan (240 mA, 140 kV) and low-dose scan of three different levels (43 mA, 140 kV; 50 mA, 120 kV; 75 mA, 80 kV) together with three different pitches (1.0, 1.5, and 2.0) were performed. The images of the simulated nodules were combined with the CT images of a normal adult's upper, middle, and inferior lung. Three radiologists read the images and the number of the nodules they detected including both the real ones and the false-positive ones was calculated to investigate weather there was any difference among different doses, pitch groups, and different locations. Results: The detection rate of the 10 mm and 5 mm nodules was 100% and 89.6% respectively by the low-dose scan. There was no difference between low-dose and conventional-dose CT (χ 2 =0.6907, P>0.70). The detection rate of 5 mm nodules declined when large pitch was used. Conclusion: The detection rates of 10 mm and 5 mm nodules had no difference between low-dose CT and conventional-dose CT. As the pitch augmented, the detection rate for the nodules declined

  17. Detection of hepatocellular carcinoma with multi-slice spiral CT by ...

    African Journals Online (AJOL)

    Ninety-four (94) patients with hepatocellular carcinoma (HCC) were examined by hepatic plain CT and contrast-enhanced CT including early arterial phase (EAP), late arterial phase (LAP) and portal venous phase (PVP) scanning. Patients were randomized into two groups to receive Iopamidol 370 mg /ml (47 patients) and ...

  18. Use of spiral CT angiography to judge central pulmonary vascular involvement from lung cancer

    International Nuclear Information System (INIS)

    Tan Qunyou; Zhao Shaohong; Wang Fangze; Cai Zulong

    2000-01-01

    Objective: To evaluate the accuracy of spiral CT angiography (SCTA) in judging central pulmonary vascular involvement from lung cancer located in the hilum and correlate the resultant images with pathologic and surgical findings. Methods: SCTA was done in 33 patients who were preoperatively diagnosed as having lung carcinoma located in the hilum. Contrast medium was injected at a rate of 3 ml/sec with a power injector. The delay time was from 20 to 25 seconds. The pitch was 1 with 3 mm-collimation. Images of central pulmonary arteries and veins were reconstructed with shaded surface display (SSD), maximum intensity projection (MIP), curved planar reformation (CPR), and multi-planar reformation (MPR). Then the relation between tumor and vessels was assessed prospectively on both 3 mm interval axial CT and SCTA images with comparison to subsequent pathologic or surgical findings. Results: (1) In showing the integrity of central pulmonary arteries and veins, images reconstructed by different ways of SCTA had different strong and weak points. (2) The grading standard in this study, with which the relation between vessels and tumor was judged, reflected the basic and common characters of central pulmonary vascular involvement by tumor located in the hilum. compared with axial CT images, SCTA was more accurate in judging the relation between central pulmonary vessels and tumor, and the correlation of SCTA imaging features with pathological patterns and surgical findings was better than that of axial CT images, P < 0.05 and P < 0.0001, respectively. Conclusion: It was feasible to show the relation between central pulmonary vessel and lung cancer located in the hilum with SCTA. And the accuracy of judging the vascular involvement with SCTA was higher than that with axial CT

  19. The spiral CT manifestations of the blood supply of primary hepatocellular carcinoma: correlation with pathological findings

    International Nuclear Information System (INIS)

    Huang Juan; Zhou Xiangping; Liu Rongbo; Chen Xian; Xu Chongyong; Yan Zhihan; Xu Jianying

    2000-01-01

    Objective: To study the correlation between the CT features of tumor blood supplies and the pathological changes in primary hepatocellular carcinoma (PHCC). Methods: Fifty cases with surgically and pathologically proved PHCC underwent spiral CT scanning (plain + dual-phase). One research group blindly evaluated the CT films obtained. According to tumor contrast enhancement and signals showed on CT, the patterns of PHCC was divided into 4 types: arterial blood supplying, portal blood supplying, arterial combining with portal blood supplying, and poorly blood supplying. Microscopically, PHCC was respectively classified into grade I to IV with Edmonson's standard, and into 4 types (trabecular, pseudo-glandular, compact, scirrhous) with WHO histological grading standard. At last, the CT features of tumor blood supplies were correlated with pathologic changes. Results: 36(72%) cases were supplied by hepatic arterial blood, 6(12%) by arterial combining with portal blood supplying, 4(8%) by portal, and 4(8%) were poorly blood supplying. The patterns of tumor blood supplies in PHCC correlated with tumor cells differentiation (P<0.05). PHCC with better tumor cells differentiation was more associated with portal blood supplies. The patterns of tumor blood supplying in PHCC correlated with the histological type of the tumor cell (P < 0.05). All of the scirrhous PHCC were lack of blood supplies, the entire compact and most of the trabecular PHCC were supplied by a arterial blood. Conclusion: The most of PHCC were supplied by hepatic arterial blood and others were supplied by portal blood, arterial combining with portal blood or lack of blood supplies. Evaluation of tumor blood supplies in PHCC is considered to be useful in differential diagnosis and treatment of PHCC

  20. Intracranial CT angiography obtained from a cerebral CT perfusion examination

    International Nuclear Information System (INIS)

    Gratama van Andel, H. A. F.; Venema, H. W.; Majoie, C. B.; Den Heeten, G. J.; Grimbergen, C. A.; Streekstra, G. J.

    2009-01-01

    CT perfusion (CTP) examinations of the brain are performed increasingly for the evaluation of cerebral blood flow in patients with stroke and vasospasm after subarachnoid hemorrhage. Of the same patient often also a CT angiography (CTA) examination is performed. This study investigates the possibility to obtain CTA images from the CTP examination, thereby possibly obviating the CTA examination. This would save the patient exposure to radiation, contrast, and time. Each CTP frame is a CTA image with a varying amount of contrast enhancement and with high noise. To improve the contrast-to-noise ratio (CNR) we combined all 3D images into one 3D image after registration to correct for patient motion between time frames. Image combination consists of weighted averaging in which the weighting factor of each frame is proportional to the arterial contrast. It can be shown that the arterial CNR is maximized in this procedure. An additional advantage of the use of the time series of CTP images is that automatic differentiation between arteries and veins is possible. This feature was used to mask veins in the resulting 3D images to enhance visibility of arteries in maximum intensity projection (MIP) images. With a Philips Brilliance 64 CT scanner (64x0.625 mm) CTP examinations of eight patients were performed on 80 mm of brain using the toggling table technique. The CTP examination consisted of a time series of 15 3D images (2x64x0.625 mm; 80 kV; 150 mAs each) with an interval of 4 s. The authors measured the CNR in images obtained with weighted averaging, images obtained with plain averaging, and images with maximal arterial enhancement. The authors also compared CNR and quality of the images with that of regular CTA examinations and examined the effectiveness of automatic vein masking in MIP images. The CNR of the weighted averaged images is, on the average, 1.73 times the CNR of an image at maximal arterial enhancement in the CTP series, where the use of plain averaging

  1. Clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot

    International Nuclear Information System (INIS)

    Wang Ximing; Wu Lebin; Sun Cong; Liu Cheng; Chao, Bao-Ting; Han Bo; Zhang Yunting; Chen Haisong; Li Zhenjia

    2007-01-01

    Objective: To explore the clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot. Methods: Eighteen patients with diagnosed Tetralogy of Fallot underwent cardiac CT angiography with 64-slice CT (CTA). Two- and three-dimensional images were used for diagnosing in all cases by means of MPR (coronal, sagital and oblique), cMPR, MIP and VRT. Results: All patients had ventricular septal defect, pulmonary stenosis and hypertrophy of right ventricle. The morphologic features of Tetralogy of Fallot were equal to echocardiography. Patent ductus arteriosus (PDA) were detected on eight patients. Main coronary artery branches and partial sub-branches were visualized in all patients. Abnormal coronary arteries were found in seven cases: both left and right main coronary artery arising from the right aortic sinus one case, right main coronary artery and circumflex (CX) arising from the right aortic sinus one case, left anterior descending (LAD) and CX arising from left aortic sinus directly one case, left and right coronary artery arising from back and front of the aortic sinus, respectively, three cases. Pulmonary artery branch stenosis was found in 12 cases and branch pulmonary artery dilation noticed in 1 case. Double superior vena cava was also found in one case. According to the surgery the diagnostic accuracy of CT and Echocardiography was 95.45 and 83.33%, respectively. Conclusion: Two- and three-dimensional 64-slice CTA not only show the overall anatomical structure of the heart, but also show coronary and pulmonary arteries. With these results, evaluation of coronary anomalies and pulmonary artery stenosis with 64-MSCT is extremely valuable for planning the operative procedure on the patients with Tetralogy of Fallot

  2. Clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot

    Energy Technology Data Exchange (ETDEWEB)

    Wang Ximing [Tianjin Medical University, Tianjin City (China) and Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China)], E-mail: wxming369@163.com.cn; Wu Lebin [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China); Sun Cong [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China); Shandong University Medical College, Shandong Jinan 250012 (China); Liu Cheng [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China); Chao, Bao-Ting [Shandong University Medical College, Shandong Jinan 250012 (China); Han Bo [Shandong Provincial Hospital Pediatric Department, Shandong, Jinan 250021 (China); Zhang Yunting [Tianjin Medical University, General Hospital MR Department, Tianjin City (China); Chen Haisong [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China); Shandong University Medical College, Shandong Jinan 250012 (China); Li Zhenjia [Shandong Medical Imaging Research Institute, Jinan City, Shandong Province 250021 (China)

    2007-11-15

    Objective: To explore the clinical application of 64-slice spiral CT in the diagnosis of the Tetralogy of Fallot. Methods: Eighteen patients with diagnosed Tetralogy of Fallot underwent cardiac CT angiography with 64-slice CT (CTA). Two- and three-dimensional images were used for diagnosing in all cases by means of MPR (coronal, sagital and oblique), cMPR, MIP and VRT. Results: All patients had ventricular septal defect, pulmonary stenosis and hypertrophy of right ventricle. The morphologic features of Tetralogy of Fallot were equal to echocardiography. Patent ductus arteriosus (PDA) were detected on eight patients. Main coronary artery branches and partial sub-branches were visualized in all patients. Abnormal coronary arteries were found in seven cases: both left and right main coronary artery arising from the right aortic sinus one case, right main coronary artery and circumflex (CX) arising from the right aortic sinus one case, left anterior descending (LAD) and CX arising from left aortic sinus directly one case, left and right coronary artery arising from back and front of the aortic sinus, respectively, three cases. Pulmonary artery branch stenosis was found in 12 cases and branch pulmonary artery dilation noticed in 1 case. Double superior vena cava was also found in one case. According to the surgery the diagnostic accuracy of CT and Echocardiography was 95.45 and 83.33%, respectively. Conclusion: Two- and three-dimensional 64-slice CTA not only show the overall anatomical structure of the heart, but also show coronary and pulmonary arteries. With these results, evaluation of coronary anomalies and pulmonary artery stenosis with 64-MSCT is extremely valuable for planning the operative procedure on the patients with Tetralogy of Fallot.

  3. Reduction of breathing irregularity-related motion artifacts in low-pitch spiral 4D CT by optimized projection binning.

    Science.gov (United States)

    Werner, René; Hofmann, Christian; Mücke, Eike; Gauer, Tobias

    2017-06-19

    Respiration-correlated CT (4D CT) is the basis of radiotherapy treatment planning of thoracic and abdominal tumors. Current clinical 4D CT images suffer, however, from artifacts due to unfulfilled assumptions concerning breathing pattern regularity. We propose and evaluate modifications to existing low-pitch spiral 4D CT reconstruction protocols to counteract respective artifacts. The proposed advanced reconstruction (AR) approach consists of two steps that build on each other: (1) statistical analysis of the breathing signal recorded during CT data acquisition and extraction of a patient-specific reference breathing cycle for projection binning; (2) incorporation of an artifact measure into the reconstruction. 4D CT data of 30 patients were reconstructed by standard phase- and local amplitude-based reconstruction (PB, LAB) and compared with images obtained by AR. The number of artifacts was evaluated and artifact statistics correlated to breathing curve characteristics. AR reduced the number of 4D CT artifacts by 31% and 27% compared to PB and LAB; the reduction was most pronounced for irregular breathing curves. We described a two-step optimization of low-pitch spiral 4D CT reconstruction to reduce artifacts in the presence of breathing irregularity and illustrated that the modifications to existing reconstruction solutions are effective in terms of artifact reduction.

  4. The use of CT-scanning at the medicolegal external postmortem examination and at the forensic autopsy

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2006-01-01

    Introduction: Can CT-scanning of deceased at the medico legal external examination improve the selection of cases to autopsy? Is CT-scanning a substitute or a supplement to the traditional forensic autopsy? Material: In 2006 60 deceased individuals from Southern Denmark (counties of Fyn and Sønde......Introduction: Can CT-scanning of deceased at the medico legal external examination improve the selection of cases to autopsy? Is CT-scanning a substitute or a supplement to the traditional forensic autopsy? Material: In 2006 60 deceased individuals from Southern Denmark (counties of Fyn...... and Sønderjylland) (15 females and 45 males) were CT-scanned before autopsy. Method: A double-blind prospective investigation of CT-scanning in autopsy cases. A multislice spiral CT-scanner (Siemens Somatom Spirit) was used. Data from the CT-scanning and the autopsy were registered in a computer database...

  5. Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemoembolization; Tomografia Computerizzata spirale multifasica dell'epatocarcinoma. Valutazione dopo chemioembolizzazione

    Energy Technology Data Exchange (ETDEWEB)

    Catalano, O.; Esposito, M.; Sandomenico, F.; Siani, A. [Ospedale S. Maria delle Grazie, Pozzuoli, NA (Italy). Servizio di Radiologia; Nunziata, A. [Ospedale S. Maria delle Grazie, Naples (Italy). Area di Diagnostica per Immagini

    2000-06-01

    The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to global chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower than 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively homogeneous areas with hyper attenuation in the arterial phase and hypo-iso attenuation in the portal and/or delayed phase, or with hypo-iso attenuation in the arterial phase and in the portal and/or delayed phase. Lipiodol CT permitted to recognize 65 nodules (1-5/patient, mean 1.5), namely 15 grade I, 21 grade II, 20 grade III and 9 grade IV. Multiphase CT identified 6 additional nodules in 5 patients, 5 hyper vascular and 1 hypo vascular, and better assessed the correct morphology and volume of grade I nodules. Only 4 of 6 nodules missed on Lipiodol CT showed oily agent uptake after a new chemo embolization session. Moreover after retreatment, carried out in 6 of 9 patients with grade I uptake (11 nodules in all), it has been found persistence of the grade I pattern in 5 nodules, grade II in 5, and grade III in 1. Lipiodol CT may miss liver nodules and underestimate the volume of nodules with poor uptake. Though Lipiodol CT should still be considered slightly more sensitive than multiphase CT, in the general opinion this

  6. Measurement and analysis of cardiopulmonary vascular in Lanzhou healthy adults with multislice spiral CT

    International Nuclear Information System (INIS)

    Shi Xiaonan; Guo Shunlin

    2013-01-01

    Objective: To constitute a normal standard of cardiopulmonary vascular diameter and size of normal adult in Lanzhou, and to compared with the other's data reported in the previous bibliography by measuring diameter and area of cardiopulmonary artery lumen of the healthy adults in Lanzhou with multislice spiral CT (MSCT). Methods: Three hundred Lanzhou adults with no cardiopulmonary disease were equally assigned to 3 groups according to their age (A group: 18-39 years, B group: 40-60 years, C group: 61-80 years; 50 females and 50 males in each group). CT data were acquired at the end of deep inspiration phase and measurements were done on 3D reconstruction image with precise landmarks. All the results were statistically analyzed. Results: The diameters and areas of the main pulmonary artery left pulmonary artery right pulmonary artery ascending aorta and descending aorta differed significantly among the 3 groups (P<0.05). In groups B and C, there were significant differences in diameters and areas of pulmonary artery left pulmonary artery and right pulmonary between different genders (P<0.05). Conclusion: Imaging standard is provided for Lanzhou adult in early diagnosis of cardiopulmonary disease. The diameters and areas of main pulmonary artery left pulmonary artery and right pulmonary artery of Lanzhou healthy adults are different from that of other regions. It may be related to the geographical environment and the state of air pollution in Lanzhou. (authors)

  7. Effect of the degree of sternal depression on the cardiac rotation in pectus excavatum: evaluation with spiral CT

    International Nuclear Information System (INIS)

    Yu Jianqun; Yang Zhigang; Li Zhenlin; Guo Yingkun; Lu Chunyan; Zhang Mei

    2004-01-01

    Objective: To evaluate the effects of the degree of sternal depression on the cardiac rotation in pectus excavatum by using spiral CT. Methods: Spiral CT features of 32 patients with surgically corrected pectus excavatum were retrospectively reviewed. They included 27 males and 5 females ranging in age from 6 months to 17 years (mean, 6.3 years). Analysis was based on relationship among the degree of sternal depression, CT depression index, cardiac rotation angle, and PV angle. Results: 32 cases of pectus excavatum presented the sternal depression (21 ± 7) mm, CT depression index 2.9 ± 1.8, cardiac rotation angle (55.9 ± 9.8) degree, and PV angle (49.8 ± 14.0) degree, respectively. The sternal depression (17 mm) in cases with CT depression index less than 2.4 was smaller than those with CT depression index 2.4-2.9 (21 mm) and CT depression index larger than 2.9 (27 mm) (F 5.39, P<0.01). Cardiac rotation angle (49.7 degree) in cases with CT depression index less than 2.4 was smaller than those with CT depression index 2.4-2.9 (55.5 degree) and CT depression index larger than 2.9 (66.9 degree) (F=7.44, P<0.01). PV angle (58.7 degree) in cases with CT depression index less than 2.4 was larger than those with CT depression index 2.4-2.9 (46.5 degree) and CT depression index more than 2.9 (42.4 degree) ( F=3.33, P<0.05). Cardiac rotation angle of pectus excavatum had positive correlation with the CT depression index (γ=0.73, P<0.01). Conclusion: Spiral CT is a better tool for revealing chest deformity and corresponding cardiac rotation. The degree of sternal depression in pectus excavatum directly influences the cardiac rotation, and they had positive correlation. (authors)

  8. [Diagnostic values of bronchoscopy and multi-slice spiral CT for congenital dysplasia of the respiratory system in infants: a comparative study].

    Science.gov (United States)

    Wang, Xing-Lu; Huang, Ying; Li, Qu-Bei; Dai, Ji-Hong

    2013-09-01

    To investigate and compare the diagnostic values of bronchoscopy and multi-slice spiral computed tomography (CT) for congenital dysplasia of the respiratory system in infants. Analysis was performed on the clinical data, bronchoscopic findings and multi-slice spiral CT findings of 319 infants (≤1 years old) who underwent bronchoscopy and/or multi-slice spiral CT and were diagnosed with congenital dysplasia of the respiratory system. A total of 476 cases of congenital dysplasia of the respiratory system were found in the 319 infants, including primary dysplasia of the respiratory system (392 cases) and compressive dysplasia of the respiratory system (84 cases). Of the 392 cases of primary dysplasia of the respiratory system, 225 (57.4%) were diagnosed by bronchoscopy versus 167 (42.6%) by multi-slice spiral CT. There were significant differences in etiological diagnosis between bronchoscopy and multi-slice spiral CT in infants with congenital dysplasia of the respiratory system (Prespiratory system caused by tracheobronchomalacia were diagnosed by bronchoscopy and all 17 cases of primary dysplasia of the respiratory system caused by lung tissue dysplasia were diagnosed by multi-slice spiral CT. Of the 84 cases of compressive dysplasia of the respiratory system, 74 cases were diagnosed by multi-slice spiral CT and only 10 cases were diagnosed by bronchoscopy. Compared with multi-slice spiral CT, bronchoscopy can detect primary dysplasia of the respiratory system more directly. Bronchoscopy is valuable in the confirmed diagnosis of tracheobronchomalacia. Multi-slice spiral CT has a higher diagnostic value for lung tissue dysplasia than bronchoscopy.

  9. Utility of dual source CT with ECG-triggered high-pitch spiral acquisition (Flash Spiral Cardio mode) to evaluate morphological features of ventricles in children with complex congenital heart defects.

    Science.gov (United States)

    Nakagawa, Motoo; Ozawa, Yoshiyuki; Nomura, Norikazu; Inukai, Sachiko; Tsubokura, Satoshi; Sakurai, Keita; Shimohira, Masashi; Ogawa, Masaki; Shibamoto, Yuta

    2016-04-01

    We evaluated the ability of dual source CT (DSCT) with ECG-triggered high-pitch spiral acquisition (Flash Spiral Cardio mode) to depict the morphological features of ventricles in pediatric patients with congenital heart defects (CHD). Between July 2013 and April 2015, 78 pediatric patients with CHD (median age 4 months) were examined using DSCT with the Flash Spiral Cardio mode. The types of ventricular abnormalities were ventricular septal defect (VSD) in 42 (the malaligned type in 11, perimembranous type in 23, supracristal type in 2, atrioventricular type in 2, and muscular type in 4), single ventricle (SV) in 11, and congenital corrected transposition of the great arteries (ccTGA) in 4. We evaluated the accuracy of the diagnosis of the VSD type. In cases of SV and ccTGA, we assessed the detectability of the anatomical features of both ventricles for a diagnosis of ventricular situs. DSCT confirmed the diagnoses for all VSDs. The type of defect was precisely diagnosed for all patients. The anatomical features of both ventricles were also depicted and ventricular situs of SV and ccTGA was correctly diagnosed. The results suggest that DSCT has the ability to clearly depict the configuration of ventricles.

  10. Clinical application of 16-slice spiral CT in reconstruction imaging of coronary artery for diagnosing coronary disense

    International Nuclear Information System (INIS)

    Mao Xinbo; Zhu Xinjin; Zeng Huiliang; Chen Xueguang

    2005-01-01

    Objective: An evaluation of the reconstructed imaging of coronary arteries with 16-slice spiral CT in diagnosis of coronary disease. Methods: The reconstructed images of coronary arteries obtained on a 16-slice spiral CT scanner were reviewed in 60 cases, on which the following techniques were applied: retrospective ECG-gating, Segment method with 75% R-R interval, volume rendering technique (VRT), maximum intensity projection (MIP), mulfiplanar reconstruction (MPR), curved planar reconstruction (CPR) and CT virtual endoscopy (CTVE). Results: In all 60 cases, different stages of CHD were revealed in 21 cases; none abnormality was found in 33; and images were in poor quality in 2 cases, which was available for diagnosis. There were 4 stents planted in 4 cases: soft plaque suspected in lcase, patent in 2 and occlude in 1. Conclusion: The reconstructed imaging of coronary arteries with 16-slice spiral CT is superior modality in evaluation of severe coronary stenosis, plaques, and the pantency of the intra-luminal stents, which is an efficient and non-invasive imaging in diagnosis of early-stage CHD and screening in high risk population. (authors)

  11. MR appearance of cartilage defects of the knee: preliminary results of a spiral CT arthrography-guided analysis

    International Nuclear Information System (INIS)

    Berg, B.C. vande; Lecouvet, F.E.; Maldague, B.; Malghem, J.

    2004-01-01

    The aim of this study was to determine signal intensity patterns of cartilage defects at MR imaging. The MR imaging (3-mm-thick fat-suppressed intermediate-weighted fast spin-echo images) was obtained in 31 knees (21 male and 10 female patients; mean age 45.5 years) blindly selected from a series of 252 consecutive knees investigated by dual-detector spiral CT arthrography. Two radiologists determined in consensus the MR signal intensity of the cartilage areas where cartilage defects had been demonstrated on the corresponding reformatted CT arthrographic images. There were 83 cartilage defects at spiral CT arthrography. In 52 (63%) lesion areas, the MR signal intensity was higher than that of adjacent normal cartilage with signal intensity equivalent to (n=31) or lower than (n=21) that of articular fluid. The MR signal intensity was equivalent to that of adjacent normal cartilage in 17 (20%) lesion areas and lower than that of adjacent cartilage in 8 (10%) lesion areas. In 6 (7%) lesion areas, mixed low and high signal intensity was observed. The MR signal intensity of cartilage defects demonstrated on spiral CT arthrographic images varies from low to high on fat-suppressed intermediate-weighted fast spin-echo MR images obtained with our equipment and MR parameters. (orig.)

  12. The use of CT-scanning at the medicolegal external postmortem examination and at the forensic autopsy

    DEFF Research Database (Denmark)

    Leth, Peter Mygind

    2006-01-01

    Introduction: Can CT-scanning of deceased at the medico legal external examination improve the selection of cases to autopsy? Is CT-scanning a substitute or a supplement to the traditional forensic autopsy? Material: In 2006 60 deceased individuals from Southern Denmark (counties of Fyn...... and Sønderjylland) (15 females and 45 males) were CT-scanned before autopsy. Method: A double-blind prospective investigation of CT-scanning in autopsy cases. A multislice spiral CT-scanner (Siemens Somatom Spirit) was used. Data from the CT-scanning and the autopsy were registered in a computer database...... and compared. Results: The scanning could be performed in 10 minutes per case. In approximately a third of the cases the cause of death could be established by CT-scanning alone. CT-scanning was found to be most useful in cases of traumatic death, and was superior to autopsy in visualizing fractures...

  13. The usefulness of three-dimensional imaging with spiral CT in the evaluation of upper airway stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Won Ho; Yoon, Dae Young; Bae, Sang Hoon; Rho, Young Soo; Jung, Yin Gyo [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-01-01

    To assess the usefulness of three-dimensional (3D) spiral CT imaging in patients with upper airway stenosis. We performed 3D spiral CT imagings in ten patients in whom upper airway stenosis was clinically suspected. Eight of these patients had upper airway stenosis caused by intubation or tracheostomy (n-6), tuberculosis (n=1), or extrinsic compression by a thyroid mass (n=1). Spiral CT scanning (30-second continuous exposure and 90-mm length) was performed with a table speed of 3mm/sec and a section thickness of 3mm. The selected starting point was the epiglottis. The resulting data were reformatted by multiplanar reformation (MPR) and shaded surface display (SSD) with peeling after reconstruction of 2mm interval. In the evaluation of location and extent of stenosis, we compared fidings of 3D imaging with those of baseline axial images (n=10), endoscopy (n=9) and operation (n=4). The locations of stenosis in eight patients were as follows;tracheostoma (n=4), subglottic region (n=3), and larynx (n=1). In all eight, 3D imaging demonstrated the location and extent of stenosis, which exactly correlated with endoscopic and operative findings. In one patient, however, another stenotic area in the tracheal bifurcation was not discovered because this lesion was not included in the field of CT scan. In two patients, the diagnosis on 3D images of no 'stenosis' was comfirmed by clinical findings or operation. No differences in diagnostic accuracy were noted between axial images, MPR, and SSD when evalvating the location and extent of stenosis; vertical extent was shown more easily by 3D imaging than by axial images, however. 3D imaging with spiral CT may be an useful adjunctive method in the evaluation of upper airway stenosis with variable causes.

  14. The usefulness of three-dimensional imaging with spiral CT in the evaluation of upper airway stenosis

    International Nuclear Information System (INIS)

    Jang, Won Ho; Yoon, Dae Young; Bae, Sang Hoon; Rho, Young Soo; Jung, Yin Gyo

    1996-01-01

    To assess the usefulness of three-dimensional (3D) spiral CT imaging in patients with upper airway stenosis. We performed 3D spiral CT imagings in ten patients in whom upper airway stenosis was clinically suspected. Eight of these patients had upper airway stenosis caused by intubation or tracheostomy (n-6), tuberculosis (n=1), or extrinsic compression by a thyroid mass (n=1). Spiral CT scanning (30-second continuous exposure and 90-mm length) was performed with a table speed of 3mm/sec and a section thickness of 3mm. The selected starting point was the epiglottis. The resulting data were reformatted by multiplanar reformation (MPR) and shaded surface display (SSD) with peeling after reconstruction of 2mm interval. In the evaluation of location and extent of stenosis, we compared fidings of 3D imaging with those of baseline axial images (n=10), endoscopy (n=9) and operation (n=4). The locations of stenosis in eight patients were as follows;tracheostoma (n=4), subglottic region (n=3), and larynx (n=1). In all eight, 3D imaging demonstrated the location and extent of stenosis, which exactly correlated with endoscopic and operative findings. In one patient, however, another stenotic area in the tracheal bifurcation was not discovered because this lesion was not included in the field of CT scan. In two patients, the diagnosis on 3D images of no 'stenosis' was comfirmed by clinical findings or operation. No differences in diagnostic accuracy were noted between axial images, MPR, and SSD when evalvating the location and extent of stenosis; vertical extent was shown more easily by 3D imaging than by axial images, however. 3D imaging with spiral CT may be an useful adjunctive method in the evaluation of upper airway stenosis with variable causes

  15. A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT

    International Nuclear Information System (INIS)

    Vembar, M.; Garcia, M.J.; Heuscher, D.J.; Haberl, R.; Matthews, D.; Boehme, G.E.; Greenberg, N.L.

    2003-01-01

    In this investigation, we describe a quantitative technique to measure coronary motion, which can be correlated with cardiac image quality using multislice computed tomography (MSCT) scanners. MSCT scanners, with subsecond scanning, thin-slice imaging (sub-millimeter) and volume scanning capabilities have paved the way for new clinical applications like noninvasive cardiac imaging. ECG-gated spiral CT using MSCT scanners has made it possible to scan the entire heart in a single breath-hold. The continuous data acquisition makes it possible for multiple phases to be reconstructed from a cardiac cycle. We measure the position and three-dimensional velocities of well-known landmarks along the proximal, mid, and distal regions of the major coronary arteries [left main (LM), left anterior descending (LAD), right coronary artery (RCA), and left circumflex (LCX)] during the cardiac cycle. A dynamic model (called the 'delay algorithm') is described which enables us to capture the same physiological phase or 'state' of the anatomy during the cardiac cycle as the instantaneous heart rate varies during the spiral scan. The coronary arteries are reconstructed from data obtained during different physiological cardiac phases and we correlate image quality of different parts of the coronary anatomy with phases at which minimum velocities occur. The motion characteristics varied depending on the artery, with the highest motion being observed for RCA. The phases with the lowest mean velocities provided the best visualization. Though more than one phase of relative minimum velocity was observed for each artery, the most consistent image quality was observed during mid-diastole ('diastasis') of the cardiac cycle and was judged to be superior to other reconstructed phases in 92% of the cases. In the process, we also investigated correlation between cardiac arterial states and other measures of motion, such as the left ventricular volume during a cardiac cycle, which earlier has been

  16. Intravenous spiral CT angiography for assessment before orthotopic liver transplantation: Comparison between tomography, MIP, 3-dimensional surface imaging and intraarterial DSA; Intravenoese Spiral-CT-Angiographie zur Evaluation vor orthotoper Lebertransplantation: Vergleiche zwischen Schnittbilddarstellung, MIP, dreidimensionaler Oberflaechendarstellung und intraarterieller DSA

    Energy Technology Data Exchange (ETDEWEB)

    Hidajat, N. [Medizinische Fakultaet der Humboldt-Univ., Berlin (Germany). Strahlenklinik und Poliklinik; Vogl, T.J. [Medizinische Fakultaet der Humboldt-Univ., Berlin (Germany). Strahlenklinik und Poliklinik; Moeller, M. [Medizinische Fakultaet der Humboldt-Univ., Berlin (Germany). Strahlenklinik und Poliklinik; Bechstein, W.O. [Medizinische Fakultaet der Humboldt-Univ., Berlin (Germany). Klinik und Poliklinik fuer Allgemein- und Transplantationschirurgie; Felix, R. [Medizinische Fakultaet der Humboldt-Univ., Berlin (Germany). Strahlenklinik und Poliklinik

    1996-11-01

    Purpose: To analyse the efficacy of intravenous spiral CT angiography (SCTA) for the evaluation before orthotopic liver transplantation (oLT) compared with DSA. Methods: Spiral CT was performed on 31 potential recipients of a liver graft in order to examine hepatic vessels, coeliac axis, splenic artery and superior mesenteric artery. The arterial vessels were reconstructed in `Maximum Intensity Projection (MIP)` and `Shaded Surface Display (SSD)`-technique. The axial images, MIP and SSD were compared in 25 patients with DSA with regard to the visualisation of the vascular anatomy, detectability of stenosis and vascular diameters. Results: The type of arterial liver supply could be determined via SCTA in all patients. Stenosis of the coeliac axis was seen in ten patients on the DSA, MIP and SSD and in eight patients on the axial images. Occlusion of the hepatic artery was clearly visualised in two patients on the DSA, axial images and MIP and in one patient on the SSD. There was no false positive diagnosis with SCTA. SSD was seen as the best technique to visualise the vessels without overshadowing. There were no significant differences between the diamters measured from the axial images, MIP and SSD images in transversal direction and the DSA images (p>0.05). Conclusion: SCTA is a greatly promising method for the imaging of vessels supplying the liver before oLT, and may convey more diagnostic information than DSA. (orig.) [Deutsch] Ziel: Bewertung der Einsetzbarkeit in intravenoesen Spiral-CT-Angiographie (SCTA) zur Evaluation vor orthotoper Lebertransplantation (oLT) im Vergleich zur DSA. Methoden: Es wurde bei 31 Patienten vor moeglicher oLT eine SCTA der Lebergefaesse einschliesslich des Truncus coeliacus, der A. lienalis und A. mesenterica superior durchgefuehrt. Die arteriellen Gefaesse wurden mittels `Maximum-Intensitaets-Projektion (MIP)`- und `Oberflaechenschattierungs(SSD)`-Technik rekonstruiert. Die Schnittbilder, MIP und SSD, wurden bei 25 Patienten

  17. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    International Nuclear Information System (INIS)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B.; Bergstrand, L.

    2001-01-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  18. Thin-section CT vs spiral CT in candidates for lung volume reduction surgery: a comparison based on radiologists' subjective preferences

    Energy Technology Data Exchange (ETDEWEB)

    Cederlund, K.; Hoegberg, S.; Rasmussen, E.; Svane, B. [Dept. of Thoracic Radiology, Karolinska Hospital, Stockholm (Sweden); Bergstrand, L. [Dept. of Radiology, Danderyds Hospital (Sweden)

    2001-03-01

    The aim of this study was to investigate whether high-resolution (HRCT) or spiral CT was preferred in evaluating severe emphysema in patients undergoing lung volume reduction surgery (LVRS), whether there is any difference in this regard between the cranial and caudal part of the lung, and whether the degree of emphysema has an impact on the radiologists' preference. The study was performed by letting four radiologists compare images obtained with the two techniques (film pairs) and decide which technique they preferred or if the techniques were considered as equal in evaluating emphysema. In evaluation of 188 film pairs, the HRCT images were preferred in 56 %, spiral CT in 19 % and the techniques considered as equal in 25 %. Spiral CT images were preferred more often in the caudal part of the lung and in more advanced emphysema compared with the HRCT images. The study confirms our clinical assumption that use of both CT techniques are valuable in evaluating advanced emphysema and there may be technical as well as histopathological reasons for this. (orig.)

  19. CT-guided brachytherapy of prostate cancer: reduction of effective dose from X-ray examination

    Science.gov (United States)

    Sanin, Dmitriy B.; Biryukov, Vitaliy A.; Rusetskiy, Sergey S.; Sviridov, Pavel V.; Volodina, Tatiana V.

    2014-03-01

    Computed tomography (CT) is one of the most effective and informative diagnostic method. Though the number of CT scans among all radiographic procedures in the USA and European countries is 11% and 4% respectively, CT makes the highest contribution to the collective effective dose from all radiographic procedures, it is 67% in the USA and 40% in European countries [1-5]. Therefore it is necessary to understand the significance of dose value from CT imaging to a patient . Though CT dose from multiple scans and potential risk is of great concern in pediatric patients, this applies to adults as well. In this connection it is very important to develop optimal approaches to dose reduction and optimization of CT examination. International Commission on Radiological Protection (ICRP) in its publications recommends radiologists to be aware that often CT image quality is higher than it is necessary for diagnostic confidence[6], and there is a potential to reduce the dose which patient gets from CT examination [7]. In recent years many procedures, such as minimally invasive surgery, biopsy, brachytherapy and different types of ablation are carried out under guidance of computed tomography [6;7], and during a procedures multiple CT scans focusing on a specific anatomic region are performed. At the Clinics of MRRC different types of treatment for patients with prostate cancer are used, incuding conformal CT-guided brachytherapy, implantation of microsources of I into the gland under guidance of spiral CT [8]. So, the purpose of the study is to choose optimal method to reduce radiation dose from CT during CT-guided prostate brachytherapy and to obtain the image of desired quality.

  20. Primary research on direct multi-slice spiral CT venography in inferior vena cava

    International Nuclear Information System (INIS)

    Gong Peiyou; Liu Fengli; Ma Xianying; Zhao Li; Wang Liping; Li Xuehua; Li Jian

    2010-01-01

    Objective: To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods: Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results: Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion: The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method. (authors)

  1. Multiplanar spiral CT enterography in patients with Crohn's disease using a negative oral contrast material: initial results of a noninvasive imaging approach

    International Nuclear Information System (INIS)

    Reittner, Pia; Goritschnig, Toria; Doerfler, Otto; Petritsch, Wolfgang; Hinterleitner, Thomas; Preidler, Klaus W.; Szolar, Dieter H.

    2002-01-01

    The aim of this study was to prospectively define the role of multiplanar spiral CT enterography with a new negative oral contrast material for noninvasive assessment of the small bowel in patients with Crohn's disease. Thirty patients with established Crohn's disease prospectively underwent spiral CT enterography at 45-60 min after distension of the small bowel with 1400 ml of a negative oral contrast material (Mucofalk water enema). Spiral CT scans were obtained 50 s after administration of intravenous contrast material with the following parameters: 5-mm collimation; 7.5-mm/s table feed; and 3-mm reconstruction interval. The adequacy of bowel opacification, luminal distension, and the contribution of two-dimensional multiplanar reformatted imaging were assessed by two observers. Spiral CT imaging findings were compared with results of enteroclysis as well as endoscopic and histological findings in all patients. Spiral CT enterography with Mucofalk water enema was well tolerated in 29 of 30 patients. Findings on spiral CT enterography were comparable with those of barium studies in 25 of 30 patients, superior to those on barium studies in 4 patients, and inferior in 1 patient (p<0.05). The addition of multiplanar reformatted images to axial spiral CT scans significantly improved observers' confidence in image interpretation (p<0.05) but did not reveal additional abnormalities. Multiplanar spiral CT enterography with Mucofalk excellently provides information in patients with Crohn's disease. This technique accurately depicts the level of small bowel obstruction and the extent of inflammatory small bowel disease and its extraluminal complications. (orig.)

  2. Dose conversion coefficients for CT examinations of adults with automatic tube current modulation

    Science.gov (United States)

    Schlattl, H.; Zankl, M.; Becker, J.; Hoeschen, C.

    2010-10-01

    Automatic tube current modulation (TCM) is used in modern CT devices. This is implemented in the numerical calculation of dose conversion coefficients for CT examinations. For four models of adults, the female and male reference models of ICRP and ICRU and a lighter and a heavier female model, dose conversion coefficients normalized to CTDIvol (DCCCT) have been computed with a Monte Carlo transport code for CT scans with and without TCM. It could be shown for both cases that reliable values for spiral CT scans are obtained when combining the results from an appropriate set of axial scans. The largest organ DCCCT are presented for typical CT examinations for all four models. The impact of TCM is greatest for chest, pelvis and whole-trunk CT examinations, where with TCM the effective DCCCT can be 20-25% lower than without TCM. Typical organs with strong dependence on TCM are thyroid, urinary bladder, lungs and oesophagus. While the DCCCT of thyroid and urinary bladder are mainly sensitive to angular TCM, the DCCCT of lungs and oesophagus are influenced primarily by longitudinal TCM. The impact of the body stature on the effective DCCCT is of the same order as the effect of TCM. Thus, for CT scans in the trunk region, accurate dose values can only be obtained when different sets of DCCCT are employed that are appropriate for the patient's sex and stature and the actual TCM settings.

  3. Radiation Exposure from CT Examinations in Japan

    OpenAIRE

    Tsushima, Yoshito; Taketomi-Takahashi, Ayako; Takei, Hiroyuki; Otake, Hidenori; Endo, Keigo

    2010-01-01

    Abstract Background Computed tomography (CT) is the largest source of medical radiation exposure to the general population, and is considered a potential source of increased cancer risk. The aim of this study was to assess the current situation of CT use in Japan, and to investigate variations in radiation exposure in CT studies among institutions and scanners. Methods Data-sheets were sent to all 126 hospitals and randomly selected 14 (15%) of 94 clinics in Gunma prefecture which had CT scan...

  4. Comparison of contrast-enhanced spiral CT scan and pulmonary angiography in diagnosing pulmonary embolism: an experimental study in pig models

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyae Young; Lee, Sun Wha [Ewha Womans University Mokdong Hospital, Seoul (Korea, Republic of); Im, Jung Gi; Goo, Jin Mo; Seo, Joon Beom; Park, Sun Won; Lee, Whal [Seoul National University College of Medicine and the Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2000-01-01

    The purpose of our study was to compare the diagnostic value of contrast-enhanced spiral CT scanning and pulmonary angiography in detecting central and peripheral pulmonary embolism (PE) in pigs. Experiments were performed in a porcine model of acute pulmonary embolism. Five pigs underwent contrast-enhanced spiral CT and pulmonary angiography after central venous administration of embolic material (Konyak). Three thoracic radiologists read the films and the results were compared with the findings of pathologic specimens. Of 85 cases of PE detected pathologically, 78 (91.8%) were visible with spiral CT and 65 (76.5%) with pulmonary angiography. Sensitivity and specificity for the detection of central emboli were 95% and 100%, respectively, with spiral CT, and 89% and 100%, respectively, with pulmonary angiography. Sensitivity and specificity for the detection peripheral emboli were 88% and 99%, respectively, with spiral CT, and 64% and 100%, respectively, with pulmonary angiography. Contrast-enhanced spiral CT is a very useful method for the diagnosis of both peripheral and central pulmonary embolism. Compared to pulmonary angiography its sensitivity and specificity are high. (author)

  5. Prevalence of emphysematous changes as shown by low-dose spiral CT screening images in 6144 healthy subjects

    International Nuclear Information System (INIS)

    Nawa, Takeshi

    2002-01-01

    We assessed the prevalence of emphysematous changes among healthy workers and retired persons, using subjective evaluations of low-dose spiral CT images obtained during thoracic CT screenings for lung cancer. Among 6144 male participants (50-69 years old; mean age, 57), we detected 686 cases (11.2%) with emphysematous changes. The majority (95.3%) of CT-detected emphysema cases were in current or former smokers, and 169 cases (24.6%) showed significant obstructive impairment. Of 236 cases with emphysematous changes in the internal region (more than 20 mm from the costal margin), 98 (41.5%) had significant obstructive impairment. Smoking was found to be the major risk factor for CT-detected emphysema. Longitudinal observation of the emphysema cases, as well as health care support for cessation of smoking, is very important. (author)

  6. Screenings of lung cancer with low dose spiral CT: results of a three year pilot study and design of the randomised controlled trial Italung-CT

    International Nuclear Information System (INIS)

    Picozzi, Giulia; Paci, Enrico; Lopes Pegna, Andrea

    2005-01-01

    Purpose: To report the results of a three-year observational pilot study of lung cancer screening with low dose computed tomography (CT) and to present the study design of a randomised clinical trial named as Italung CT. Materials and methods: Sixty (47 males and 13 females, mean age 64±4.5 years) heavy smokers (at least 20 packs-year) underwent three low-dose spiral CT screening tests one year apart on a single slice or multislice CT scanner. Indeterminate nodules were managed according to the recommendations of the Early Lung Cancer Action Project. Results: Indeterminate nodules were observed in 33 (55%) of the subjects (60% at the baseline screening test, 24% at the first annual test and 16% at the second annual test). The size of the largest indeterminate nodule was [it

  7. Differentiation between sarcoidosis and Hodgkin’s lymphoma based on mediastinal lymph node involvement pattern: Evaluation using spiral CT scan

    International Nuclear Information System (INIS)

    Mehrian, Payam; Ebrahimzadeh, Seyed Amir

    2013-01-01

    The purpose of this study was to determine the specific and detailed anatomic sites and morphologic characteristics of mediastinal lymph nodes on spiral computed tomography for the purpose of differentiation between sarcoidosis and Hodgkin’s lymphoma. Anatomical distribution of mediastinal lymph nodes on spiral CT was reviewed in 39 patients with sarcoidosis and 37 patients with Hodgkin’s lymphoma using the International Association for the Study of Lung Cancer (IASLC) lymph node map. Other morphologic features such as lymph node calcification or coalescence of adjacent lymph nodes were also compared. Zone 10 was involved more often in sarcoidosis than in Hodgkin’s lymphoma. On the other hand, there was a higher tendency for presence of zone 1 and 3 as well as retrocrural and internal mammary lymphadenopathy in Hodgkin’s lymphoma than in sarcoidosis. Sarcoidosis presented with intranodal calcifications more often than Hodgkin’s lymphoma. Coalescence, pressure effect on adjacent structures and central cavitations were significantly more common in Hodgkin’s lymphoma. Findings of the present study indicate that specific anatomical distribution and morphological patterns of mediastinal lymph nodes, as demonstrated on spiral CT, can be useful in differentiating sarcoidosis from Hodgkin’s lymphoma

  8. The influence factors in image quality of multi-slice spiral CT coronary angiography (MSCTA)

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Jianhao; Zhong Yingze; Chen Xueguang; Ou Weiqian; Wen Haomao; Li Peiwen

    2007-01-01

    Objective: To evaluate the influence of heart rate on image quality of multi-slice spiral CT coronary angiography(MSCTA) and the optimization of image reconstruction windows. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 67 cases. The cases were divided into four groups by heart rate, groupl with heart rate less than 60 beats per minute(bpm), group 2 with heart rate 61-70 bpm, group 3 with heart rate 71-80 bpm and group 4 with heart rate over 81 bpm. The impact of heart rate on image quality of MSCTA and the optimization of image reconstruction windows were evaluated. Results: 4 coronary (RCA,LM,LAD,LCX) segments were analyzed in each patients with regard to image quality. 86.7%(112/128) of the coronary segments were sufficient for analysis in patients with heart rate less than 60 bpm,62.5%(55/88) with 61-70 bpm,40%(8/20) with 71-80 bpm and 12.5%(2/16) with heart rate over 81 bpm, respectively. There were statistically significances between every coronary segments of group 1 and 2, group 3 and 4 (P<0.05). All coronary segments of group 1 were optimally visualized on the image reconstructed at 75% image reconstruction window of' cardiac cycle; 89.5% cases at 75% in group 2; for group 3.55% of coronary artery were best presented at 75% image reconstruction window, 45% of coronary artery at 45%; All coronary segments of group 4 were optimally visualized on the image reconstructed at 45% image reconstruction window. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate. Coronary artery is usually best shown at 75% image reconstruction window of cardiac cycle for those with heart rate less than 70 bpm. 30%-90% image reconstruction should be performed when heart rate is over 71 bpm. (authors)

  9. Multidetector spiral CT renal angiography in the diagnosis of renal artery fibromuscular dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Sabharwal, Rohan [Department of Radiology, Westmead Hospital, Sydney, NSW (Australia)]. E-mail: rohan50000@yahoo.com; Vladica, Philip [Department of Radiology, Westmead Hospital, Sydney, NSW (Australia); Coleman, Patrick [Department of Renal Medicine, Westmead Hospital, Sydney, NSW (Australia)

    2007-03-15

    Objective: The aim of this study was to evaluate the role and detection rate of multidetector spiral CT renal angiography (CTA) as compared with conventional angiography (CA), the commonly accepted gold standard, in the diagnosis of renal artery fibromuscular dysplasia (FMD). In addition, the role of CTA reconstructions (multiplanar reformatted images (MPR), maximum intensity projections (MIP) and shaded-surface display (SSD)) in the detection of FMD was also evaluated. Materials and methods: CTA results were retrospectively reviewed in 21 hypertensive patients with CA-proven FMD. Clinical indications for referral included resistant hypertension (requiring greater than three antihypertensive medications), labile hypertension, hypertension in combination with renal impairment and the presence of abdominal bruits in the context of systemic hypertension. In some cases, these clinical indications were supplemented by positive results in other tests, including plasma renin assay, captopril scintigraphy and/or Doppler ultrasound. The findings of CA in these 21 patients were compared to CTA. Results: Mean patient age was 62.33 + 14.32 years (range 24-85 years). CTA identified all 42 main renal arteries (100%) and all 10 accessory renal arteries (100%) visualized on CA. In the diagnosis of FMD, CTA detected all 40 (100%) lesions detected by CA. No single CTA reconstruction technique was able to detect all lesions noted on corresponding CA, however, upon review of all CTA reconstructions (MPR, MIP and SSD) in each case, every lesion was correctly identified by CTA. Conclusion: Our experience suggests that CTA is a non-invasive, reliable and accurate method for the diagnosis of renal artery fibromuscular dysplasia. Moreover, in our experience CTA has many advantages as a diagnostic screening tool over CA, including accessibility, speed, lower complication profile, versatility and cost-effectiveness. CTA shows great potential as a guiding tool for directing subsequent

  10. Correlation between spiral CT signs and PTEN expression in gastric cancer infiltration and metastasis

    International Nuclear Information System (INIS)

    Chen Jianfeng; Fei Lun; Wang Peiyun; Wu Maozhu; Chen Yiming; Zhang Caineng; Liang Xuefeng

    2011-01-01

    Objective: To evaluate the potential link between spiral CT (SCT) signs and PTEN expression in gastric cancer and the correlation with clinico pathology. Methods: Sixty patients with advanced gastric cancer were selected. SCT three-phase enhanced scan was conducted on them a week before surgery. HE staining, smearing and SP immunohistochemical staining were conducted on specimens after surgery to detect PTEN expression. Results: SCT showed the accuracy of determining serosal invasion was 91.66% (55/60), that of determining lymph node metastases was 78.95% (45/57), and that of determining distant metastases was 100% (4/4), of which, four patients with distant metastases combined with lymph node metastases. SCT diagnosis and pathological diagnosis of serosal invasion (T3 + T4) and lymph node metastasis (including distant metastasis) showed a good consistency (P values were 0.00013 and 0.00011, respectively). Diagnosed by SCT, the positive rate of PTEN expression in patients with no serosal invasion was 75.00%, significantly higher than that (27.08%) of patients with serosal invasion (P<0.05); that of patients with no lymph node metastasis was 100.00%, significantly higher than that (33.33%) of patients with lymph node metastasis (P<0.05); that of patients with no distant metastasis was 39.29%, and of 4 patients with distant metastasis, the two groups showed significant differences (P<0.05). Conclusion: PTEN is an important biological indicator to predict the metastatic potential of gastric cancer cells. Gastric cancer patients who have low PTEN expression possessed a higher metastatic potential, while SCT signs is closely related to PTEN expression in tumor cells. Clinically, biological characteristics of gastric cancer can be speculated by SCT signs noninvasively,and thus a reasonable assessment is conducted on the invasion,metastasis and prognosis of gastric cancer to guide and develop rational treatment plans. (authors)

  11. The value of 64-slice spiral CT perfusion imaging in the treatment of liver cancer with argon-helium cryoablation.

    Science.gov (United States)

    Lv, Yinggang; Jin, Yurong; Yan, Qiaohuan; Yuan, Dingling; Wang, Yanling; Li, Xianping; Shen, Yanfeng

    2016-12-01

    We analyzed the effectiveness of using 64-slice spiral computed tomography (CT) and perfusion imaging to guide argon-helium cryoablation treatment of liver cancer. In total, 60 cases of advanced hepatocellular carcinoma before surgery treated with argon-helium cryoablation were inlcuded in the present study. Retrospective summary of the 60 cases of metaphase and advanced liver cancer were used as the control group. The control group were treated using cryoablation with argon-helium knife. We used enhanced scanning with 64-slice spiral CT to define the extent of their lesions and prepared a plan of percutaneous cryoablation for the treatment. Intraoperatively, we used the dynamics of CT perfusion imaging to observe the frozen ablation range and decreased the rate of complications. After surgery, the patients were followed-up regularly by 64-slice CT. We used conventional X-ray, CT and magnetic resonance imaging (MRI) for pre-operative lateralization. Intraoperative X-ray or ultrasound guidance and follow-up with CT or MTI were added to determine the clinical effectiveness and prognosis. The results showed that the total effective rate was improved significantly and incidence rate of overall complications decreased markedly in the observation group. Following treatment, AFP decreased significantly while the total freezing area and time were reduced significantly. The median survival time was increased significantly in the observation group. The numeric values of hepatic arterial perfusion, portal vein perfusion and hepatic arterial perfusion index were all markedly lowered after treatment. Differences were statistically significant (PCT perfusion imaging may considerably improve the effects of liver cancer treatment using the argon-helium cryoablation. It extended the survival time and reduced complications.

  12. Measuring of the airway dimensions with spiral CT images: an experimental study in Japanese white big-ear rabbits

    International Nuclear Information System (INIS)

    Han Xinwei; Lu Huibin; Ma Ji; Wu Gang; Wang Nan; Si Jiangtao

    2009-01-01

    Objective: To measure the length, angle and their correlation of the main anatomical dimensions of the trachea and bronchus in experimental Japanese white big-ear rabbits with the help of spiral CT 3D images, in order to lay the foundation of treating the airway disorders with stenting in animal experiment. Methods: Multi-slice CT scanning of cervico-thoracic region was performed in 30 healthy adult Japanese white big-ear rabbits, the longitudinal, transversal dimensions of the trachea, the glottis-carina length, the inner diameter and length of bronchi, and the angle formed by bronchial long axis and sagittal section were measured. Results: No significant difference was found in the inner diameters of various parts of the trachea and upper apical bronchi. The angle formed by bronchial long axis and sagittal section were smaller than that of the left ones. And the inner diameters of the right main bronchus was bigger than the left ones. Conclusion: The complex branching structure of the rabbit airway tree can be well displayed on spiral CT 3D images. Through measuring and statistical analysis of the results the authors have got a regressive equation for estimating the value of the inner diameter, length, angle, etc. concerning the airway tree, which is very helpful for providing the useful anatomical parameters in rabbit experiment. (authors)

  13. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography; Die Rolle der Ganzkoerper-Spiral-CT bei der Primaerdiagnostik polytraumatisierter Patienten - Vergleich mit konventioneller Radiographie und Abdomensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J. [Klinik und Poliklinik fuer Radiologie und Nuklearmedizin, Charite - Campus Benjamin Franklin (Germany); Stahel, P.F.; Ertel, W. [Klinik fuer Unfall- und Wiederherstellungschirurgie, Charite - Campus Benjamin Franklin (Germany)

    2004-08-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  14. [Detection of tibial condylar fractures using 3D imaging with a mobile image amplifier (Siemens ISO-C-3D): Comparison with plain films and spiral CT].

    Science.gov (United States)

    Kotsianos, D; Rock, C; Wirth, S; Linsenmaier, U; Brandl, R; Fischer, T; Euler, E; Mutschler, W; Pfeifer, K J; Reiser, M

    2002-01-01

    To analyze a prototype mobile C-arm 3D image amplifier in the detection and classification of experimental tibial condylar fractures with multiplanar reconstructions (MPR). Human knee specimens (n = 22) with tibial condylar fractures were examined with a prototype C-arm (ISO-C-3D, Siemens AG), plain films (CR) and spiral CT (CT). The motorized C-arm provides fluoroscopic images during a 190 degrees orbital rotation computing a 119 mm data cube. From these 3D data sets MP reconstructions were obtained. All images were evaluated by four independent readers for the detection and assessment of fracture lines. All fractures were classified according to the Müller AO classification. To confirm the results, the specimens were finally surgically dissected. 97 % of the tibial condylar fractures were easily seen and correctly classified according to the Müller AO classification on MP reconstruction of the ISO-C-3D. There is no significant difference between ISO-C and CT in detection and correct classification of fractures, but ISO-CD-3D is significant by better than CR. The evaluation of fractures with the ISO-C is better than with plain films alone and comparable to CT scans. The three-dimensional reconstruction of the ISO-C can provide important information which cannot be obtained from plain films. The ISO-C-3D may be useful in planning operative reconstructions and evaluating surgical results in orthopaedic surgery of the limbs.

  15. [Application of computed tomography (CT) examination for forensic medicine].

    Science.gov (United States)

    Urbanik, Andrzej; Chrzan, Robert

    2013-01-01

    The aim of the study is to present a own experiences in usage of post mortem CT examination for forensic medicine. With the help of 16-slice CT scanner 181 corpses were examined. Obtained during acquisition imaging data are later developed with dedicated programmes. Analyzed images were extracted from axial sections, multiplanar reconstructions as well as 3D reconstructions. Gained information helped greatly when classical autopsy was performed by making it more accurate. A CT scan images recorded digitally enable to evaluate corpses at any time, despite processes of putrefaction or cremation. If possible CT examination should precede classical autopsy.

  16. Comparison of laterally condensed, vertically compacted thermoplasticized, cold free-flow GP obturations – A volumetric analysis using spiral CT

    Science.gov (United States)

    Kandaswamy, Deivanayagam; Venkateshbabu, Nagendrababu; Krishna, Reddy Gopi; Hannah, Rosaline; Arathi, Ganesh; Roohi, Riaz

    2009-01-01

    Aim/Objective: To compare the laterally condensed gutta-percha, vertically compacted thermoplastized gutta-percha (E and Q Plus system) and cold free-flow gutta–percha (GuttaFlow). This is a volumetric analysis using spiral CT, an in vitro study. Materials and Methods: Access cavities were prepared in 60 single rooted anterior teeth; cleaning and shaping was done and obturated with three of the different techniques: group A: cold lateral; group B: vertically compacted thermoplasticized and group C: cold free-flow obturation techniques. Volume analysis was done using spiral computed tomography (CT). The percentage difference was calculated and statistically analyzed using one-way ANOVA and post hoc multiple comparison Tukey HSD tests. Results: There were statistical significant differences between group A (0.183cm3) and group B (0.136cm3); group A (0.183cm3) and group C (0.128cm3). But there was no statistical significance between group B (0.136cm3) and group C (0.128cm3). Conclusion: Within the limitations of this in vitro study it can be concluded that cold free-flow obturation technique showed the highest volume of obturation, followed by the vertically condensed thermoplasticized technique. The least volume of obturation was observed in cold lateral condensation technique. PMID:20543923

  17. Gastric wall thickening on spiral CT after subtotal gastrectomy for gastric cancer: comparision between recurrent caner and benign thickening

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chang Sook; Choi, Jong Cheol; Yoon, Sung Kuk; Kim, Jae Ik; Oh, Jong Young; Kang, Myung Jin; Lee, Ki Nam; Nam, Kyuung Jin [Donga Univ. College of Medicine, Pusan (Korea, Republic of)

    2000-12-01

    To determine the features revealed by two-phase spiral CT scanning useful for differential diagnosis between recurrent cancer and benign wall thickening in patients who have undergone subtotal gastrectomy for stomach cancer. We retrospectively reviewed 25 cases in which wall thickening of more than 1cm in the remnant stomach after subtotal gastrectomy was revealed by two-phase spiral CT scanning. All cases were confirmed: 11 were recurrent cancer, and in 14, benign wall thickening was demonstrated. We analyzed the CT findings including maximal thickness of the gastric wall, patterns of wall thickening, degree of contrast enhancement seen during the arterial and portal phases, and the presence of perigastric strands. Maximal wall thickness was classified as either more or less than 15mm, and as either focal or diffuse. We also determined whether lymphadenopathy was present. Mean maximal gastric wall thickness was 18.4mm in the recurrent cancer group ({sup g}roup A{sup )} and 12.6mm in the benign group ({sup g}roup B{sup )}. The gastric wall was thicker than 15mm in 10 of 11 group A cases and in 3 of 14 in group B; wall thickening was focal (n=3) or diffuse (n=8) in group A, and focal (n=13) or diffuse (n=1) in group B, while the enhancement patterns seen during the arterial and portal phase, respectively, were high/high (n=8), low/high (n=1) and low/low (n=2) in group A, and low/low (n=7), low/high (n=4), high/low (n=1) and high/high (n=2) in group B. Perigastric strands were observed in nine cases in group A, but in none in group B, while lymphadenopathy was combined with wall thickening in seven group A cases but in none of those in group B. In patients who have undergone subtotal gastrectomy for gastric cancer, two-phase spiral CT findings including maximal thickness of the gastric wall, patterns of wall thickening, degree of contrast enhancement seen during the arterial and portal phase, the presence of perigastric strands, and lymphadenopathy are useful for

  18. Hemodynamic change by portal tumor thrombus in hepatocellular carcinoma; evaluation by combined spiral CT hepatic arteriography and CT arterial portography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mee Ran; Kim, Yun Hwan; Kim, Kyung A; Seol, Hae Young; Chung, Kyoo Byung; Suh, Won Hyuk [Korea Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-01-01

    To evaluate the hemodynamioc change by portal tumor thrombus in hepatocellular carcinoma(HCC). We reviewed 35 cases of combined spiral CTHA and CTAP in 25 HCC patients with portal tumor thrombus from April 1993 to October 1994, regarding to portal tumor thrombus, the involved area of arterioportal(AP) shunt and the development of cavernous transformation of portal vein, in comparison with hepatic and superior mesenteric arteriography. Spiral CTHA showed hyperattenuating tumor, portal tumor thrombus and hyperattenuating peritumoral parenchymal area. Spiral CTAP showed perfusion defect area including tumor, portal tumor thrombus and peritumoral area distal to portal vein obstruction. In 15 cases, portal tumor thrombus showed intraluminal and marginal hyperattenuating linear structures on CTHA due to transvasal AP shunt and tumor feeding arteries, which were corresponding to thread and streaks sign on hepatic arteriography. Cavernous transformation of portal vein was demonstrated in 15 cases as irregular periportal hyperattenuating collateral vessels on spiral CTAP. In 32 cases, portal vein was visualized on CTHA due to AP shunt. And according to shunt amount, we classified AP shunt into 4 grades. Grade I means only the presence of portal tumor thrombus without Ap shunt, grade II with segmental AP shunt, grade III with one lobar AP shunt, and grade IV with both lobar AP shunt or the presence of cavernous transformation of portal vein. Grade I was seen in 3, grade II in 4, grade III in 13 and grade IV in 15 cases. Variable CTHA and CTAP findings were shown in HCC patients with portal tumor thrombus according to the amount of AP shunt and the presence of cavernous transformation of portal vein. Combined CTHA and CTAP are useful to differentiate the tumor thrombus from simple thrombus and are very sensitive method for detecting AP shunt. Understanding these findings related with portal tumor thrombus is important to predict patient's prognosis and to decide

  19. Severity of acute pulmonary embolism: evaluation of a new spiral CT angiographic score in correlation with echocardiographic data

    Energy Technology Data Exchange (ETDEWEB)

    Mastora, Ioana; Remy-Jardin, Martine; Masson, Pascal; Remy, Jacques [Department of Radiology, University Center Hospital Calmette, Boulevard Jules Leclerc, 59037 Lille Cedex (France); Medical Research Group ' ' Equipe d' Accueil no. 2682' ' , Boulevard Jules Leclerc, 59037 Lille Cedex (France); Galland, Eric; Bauchart, Jean-Jacques [Department of Cardiology, University Center Cardiology Hospital; Boulevard Jules Leclerc, 59037 Lille Cedex (France); Delannoy, Valerie [Department of Medical Statistics, University of Lille, Place de Verdun, 59037 Lille Cedex (France)

    2003-01-01

    The purpose of this study was to investigate whether the severity of acute pulmonary embolism (PE) could be quantitatively assessed with spiral CT angiography (SCTA). Thirty-six consecutive patients without underlying cardiopulmonary disease and high clinical suspicion of PE underwent prospectively thin-collimation SCTA and echocardiography at the time of the initial diagnosis (T0) and after initial therapy (T1; mean interval of time T1-T2: 32 days). The CT severity score was based on the percentage of obstructed surface of each central and peripheral pulmonary arterial section using a 5-point scale (1: <25%; 2: 25-49%; 3: 50-74%; 4: 75-99%; 5: 100%). The sum of the detailed scores attributed to 5 mediastinal, 6 lobar and 20 segmental arteries per patient led to the determination of central, peripheral and global CT severity scores and subsequent determination of percentages of obstruction of the pulmonary circulation. Echocardiographic severity criteria included the presence of signs of acute cor pulmonale and/or systolic pulmonary hypertension (>40 mm Hg). The SCTA depicted acute PE in all patients at T0 with complete resolution of endovascular clots in 10 patients at T1. At T0, the mean percentage of obstruction of the pulmonary arterial bed was significantly higher in the 22 patients with echocardiographic signs of severity (56{+-}13 vs 28{+-}32%; p<0.001). A significant reduction in the mean percentage of pulmonary artery obstruction was observed in the 19 patients with resolution of echocardiographic criteria of severity between T0 and T1 T0: 57{+-}14%; T1: 7{+-}11%; p<0.001. The threshold value for severe PE on CT angiograms was 49% (sensitivity: 0.773; specificity: 0.214). The mean ({+-}SD) pulmonary artery pressure was significantly higher in the 26 patients with more than 50% obstruction of the pulmonary artery bed (45{+-}15 mm Hg) than in the 10 patients with less than 50% obstruction of pulmonary artery bed at T0 (31{+-}11 mm Hg; p<0.01). The CT

  20. Examination of jaws and teeth using Dental CT

    International Nuclear Information System (INIS)

    Nikolov, Vl.

    2001-01-01

    The aim of the present work was to establish a new method for dental imaging using Dental CT. Dental computer assisted tomography represents valuable addition to the diagnostics spectrum for planning oral and maxillofacial surgery. High resolution spiral CT and specially designed computer software allow representation of the jaws in different planes that are easy to match. The further allow the display of very small structures relevant to oral surgical interventions and reveal their spatial relationship in three dimensions. Dental CT is indicated, when clinical and conventional radiological techniques will not allow exact interpretation of the situation. It is modern oral implantology that primarily benefits from computer software enabling the assessment of surgical sites in the pre surgical phase. Such planning was not yet possible using two dimensional radiographic techniques. The dental-implantological part expects from radiography sharply defined contours of the external bony contours and the mandibular canal, exactly defined relation between slices and planes, no distortion in the ortho-radial planes, tools for reliable measurements of distances, angles and volumes, possibility to transmit pictures electronically or on hardcopy without loss of quality. Thus communication between dentists and radiologists may and must be intensified and supported by usage of modern telecommunication systems. (author)

  1. Virtual reality publication of spiral ct-derived three-dimensional models: or, creation of spiral, CT-derived, three-dimensional VRML objects.

    Science.gov (United States)

    Tyszka, J M

    1997-01-01

    Three-dimensional models can be generated from slice images, such as those obtained from computed tomography (CT) and magnetic resonance imaging (MRI) using a variety of techniques. A popular method for rendering 3D anatomical models is the creation of polygonal mesh surfaces representing the boundary between tissues. Mesh surfaces can be rendered extremely quickly using conventional personal computers, without recourse to more expensive graphic workstations. The dissemination of three-dimensional (3D) models across the Internet has been made significantly easier by the definition of the Virtual Reality Markup Language (VRML) format. The VRML definition allows the parameters and relationships of 3D objects to be described in a text format. The text file can be transfered from a host computer to a remote client computer through the World Wide Web and viewed using readily available software (See Appendix). VRML is based on the definition of primitive 3D objects such as polygons and spheres. Consequently, the transition from a mesh surface derived from a clinical image data set to a VRML object is relatively simple, allowing for convenient and cost-effective dissemination of 3D clinical models across the internet.

  2. On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations.

    Science.gov (United States)

    Perisinakis, Kostas; Tzedakis, Antonis; Damilakis, John

    2008-05-01

    The purpose of this work was to investigate the applicability and appropriateness of Monte Carlo-derived normalized data to provide accurate estimations of patient dose from computed tomography (CT) exposures. Monte Carlo methodology and mathematical anthropomorphic phantoms were used to simulate standard patient CT examinations of the head, thorax, abdomen, and trunk performed on a multislice CT scanner. Phantoms were generated to simulate the average adult individual and two individuals with different body sizes. Normalized dose values for all radiosensitive organs and normalized effective dose values were calculated for standard axial and spiral CT examinations. Discrepancies in CT dosimetry using Monte Carlo-derived coefficients originating from the use of: (a) Conversion coefficients derived for axial CT exposures, (b) a mathematical anthropomorphic phantom of standard body size to derive conversion coefficients, and (c) data derived for a specific CT scanner to estimate patient dose from CT examinations performed on a different scanner, were separately evaluated. The percentage differences between the normalized organ dose values derived for contiguous axial scans and the corresponding values derived for spiral scans with pitch = 1 and the same total scanning length were up to 10%, while the corresponding percentage differences in normalized effective dose values were less than 0.7% for all standard CT examinations. The normalized organ dose values for standard spiral CT examinations with pitch 0.5-1.5 were found to differ from the corresponding values derived for contiguous axial scans divided by the pitch, by less than 14% while the corresponding percentage differences in normalized effective dose values were less than 1% for all standard CT examinations. Normalized effective dose values for the standard contiguous axial CT examinations derived by Monte Carlo simulation were found to considerably decrease with increasing body size of the mathematical

  3. Motion estimation and compensation in dynamic spiral CT reconstruction; Estimation et compensation de mouvement en reconstruction dynamique de tomodensitometrie helicoidale

    Energy Technology Data Exchange (ETDEWEB)

    Kimdon, J.; Grangeat, P.; Koenig, A.; Bonnet, St

    2004-07-01

    Respiratory and cardiac motion causes blurring in dynamic X-ray Computed Tomography (CT). Fast scans reduce this problem, but they require a higher radiation dose per time period to maintain the signal to noise ratio of the resulting images, thereby magnifying the health risk to the patient. As an alternative to increased radiation, our team has already developed a cone-beam reconstruction algorithm based on a dynamic particle model that estimates, predicts, and compensates for respiratory motion in circular X-ray CT. The current paper presents an extension of this method to spiral CT, applicable to modern multi-slice scanners that take advantage of the speed and dose benefits of helical trajectories. We adapted all three main areas of the algorithm: backprojection, prediction, and compensation/accumulation. In backprojection, we changed the longitudinal re-binning technique, filter direction, and the method of enforcing the data sufficiency requirements. For prediction, we had to be careful of objects appearing and disappearing as the scanner bed advanced. For compensation/accumulation, we controlled the reconstruction time and combined images to cover a greater longitudinal extent for each phase in the respiratory or cardiac cycle. Tests with moving numerical phantoms demonstrate that the algorithm successfully improves the temporal resolution of the images without increasing the dose or reducing the signal-to-noise ratio. (authors)

  4. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: a phantom study.

    Science.gov (United States)

    Feng, Shi-Ting; Law, Martin Wai-Ming; Huang, Bingsheng; Ng, Sherry; Li, Zi-Ping; Meng, Quan-Fei; Khong, Pek-Lan

    2010-11-01

    To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. The effective doses for head, thorax, abdomen and pelvis CT, were 0.7mSv, 3.5mSv, 3.0mSv, 1.3mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33mGy); for thorax CT, breast (7.89mGy); for abdomen CT, colon (6.62mGy); for pelvis CT, bladder (4.28mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). The effective doses from these common pediatric CT examinations ranged from 0.7mSv to 3.5mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  5. Techniques and radiation dose in CT examinations of adult patients

    International Nuclear Information System (INIS)

    Elameen, S. E. A.

    2010-06-01

    The use of CT in medical diagnosis delivers radiation dose to patients that are higher than those from other radiological procedures. Lake of optimized protocols could be an additional source of increased dose. The aim of this study was to measure radiation doses in CT examination of the adults in three Sudanese hospitals. Details were obtained from approximately 160 CT examination carried out in 3 hospitals (3 CT scanners). Effective dose was calculated for each examination using CT dose indices. exposure related parameters and CT D1- to- effective dose conversion factors. CT air kerma index (CT D1) and dose length products (DLP) determined were below the established international reference dose levels. The mean effective doses in this study for the head, chest, and abdomen are 0.82, 3.7 and 5.4 mGy respectively. These values were observed that the effective dose per examination was lower in Sudan than in other countries. The report of a CT survey done in these centers indicates that the mean DLP values for adult patients were ranged from 272-460 mGy cm (head) 195-995 mGy cm (chest), 270-459 mGy cm (abdomen). There are a number of observed parameters that greatly need optimization, such as minimize the scan length, without missing any vital anatomical regions, modulation of exposure parameters (kV, mA, exposure time, and slice thickness) based on patient size and age. Another possible method is through use of contrast media only to optimize diagnostic yield. The last possible method is the use of radio protective materials for protection however, in order to achieve the above optimization strategies: there is great demand to educate CT personnel on the effects of scan parameter settings on radiation dose to patients and image quality required for accurate diagnosis. (Author)

  6. Characterization of liver lesions with mangafodipir trisodium-enhanced MR imaging: multicenter study comparing MR and dual-phase spiral CT

    NARCIS (Netherlands)

    M. Oudkerk (Matthijs); C.G. Torres; B. Song; M. Konig; J. Grimm; J. Fernandez-Cuadrado; B. op de Beeck; M. Marquardt; P. van Dijk (Pieter); J.C. de Groot (Jan Cees)

    2002-01-01

    textabstractPURPOSE: To evaluate whether mangafodipir trisodium (Mn-DPDP)-enhanced magnetic resonance (MR) imaging surpasses dual-phase spiral computed tomography (CT) in differentiating focal liver lesions. MATERIALS AND METHODS: One hundred forty-five patients who had or were

  7. Multi-slice spiral CT coronary angiography: influence of heart rate and reconstruction window on image quality

    International Nuclear Information System (INIS)

    Mao Dingbiao; Hua Yanqing; Wang Mingpeng; Zhang Guozhen; Wu Weilan; Hu Fei; Ge Xiaojun; Ding Qiyong

    2004-01-01

    Objective: To evaluate the influence of heart rate and reconstruction window on image quality of multi-slice spiral CT coronary angiography. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 80 healthy cases. Results: Four coronary (RCA, LM, LAD, LCX) segments were analyzed in each patient with regard to image quality. 82.1% (46/56) of the coronary segments were sufficient for analysis in patients with heart rate ≤60 bpm, 63.4% (104/164) with 61-70 bpm, 41.2%(28/68) with 71-80 bpm, and 31.2%(10/32) with>80 bpm, respectively. The left anterior descending artery, left circumflex artery, and the right coronary artery were best visualized when the reconstruction window was 60%-70%, 50%-60%, and 50%-70%, respectively. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate and reconstruction window

  8. Estimating cancer risks to adults undergoing body CT examinations.

    Science.gov (United States)

    Huda, Walter; He, Wenjun

    2012-06-01

    The purpose of the study is to estimate cancer risks from the amount of radiation used to perform body computed tomography (CT) examination. The ImPACT CT Patient Dosimetry Calculator was used to compute values of organ doses for adult body CT examinations. The radiation used to perform each examination was quantified by the dose-length product (DLP). Patient organ doses were converted into corresponding age and sex dependent cancer risks using data from BEIR VII. Results are presented for cancer risks per unit DLP and unit effective dose for 11 sensitive organs, as well as estimates of the contribution from 'other organs'. For patients who differ from a standard sized adult, correction factors based on the patient weight and antero-posterior dimension are provided to adjust organ doses and the corresponding risks. At constant incident radiation intensity, for CT examinations that include the chest, risks for females are markedly higher than those for males, whereas for examinations that include the pelvis, risks in males were slightly higher than those in females. In abdominal CT scans, risks for males and female patients are very similar. For abdominal CT scans, increasing the patient age from 20 to 80 resulted in a reduction in patient risks of nearly a factor of 5. The average cancer risk for chest/abdomen/pelvis CT examinations was ∼26 % higher than the cancer risk caused by 'sensitive organs'. Doses and radiation risks in 80 kg adults were ∼10 % lower than those in 70 kg patients. Cancer risks in body CT can be estimated from the examination DLP by accounting for sex, age, as well as patient physical characteristics.

  9. JOURNAL CLUB: CT dose optimization for whole-body PET/CT examinations.

    Science.gov (United States)

    Tonkopi, Elena; Ross, Andrew A; MacDonald, Anita

    2013-08-01

    OBJECTIVE. The objective of this study was to optimize CT protocols for whole-body PET/CT by reducing radiation dose while minimizing effects on image quality. MATERIALS AND METHODS. Before protocol optimization, a survey of 140 consecutive patients was conducted to establish the baseline dose from a whole-body PET/CT examination. Another sample of 100 patients was surveyed to evaluate the reduction of radiation dose after implementation of the new protocol. Effective dose from the CT component of the examination was estimated using dose-length product (DLP) values from reports generated by the scanner and anatomy-specific conversion factors. Twenty-six patients who underwent studies before and after the optimization were included in an analysis of image quality. All 26 patients had maintained the same weight between the examinations and were scanned in the same position using a similar technique except for the changes made for CT dose optimization. The studies were randomized and blinded for an experienced PET and CT reader who graded the imaging quality of anatomic structures. RESULTS. CT protocol optimization resulted in a 32% reduction of the mean CT radiation dose: The mean effective dose was reduced from 8.1 to 5.5 mSv. The blinded analysis of image quality showed no clinically significant degradation of the lower-dose studies. The only structures visualized statistically better on the higher-dose CT scans were the carotid arteries and the region of the posterior triangle. CONCLUSION. The results of this study showed that optimization of CT acquisition can effectively reduce radiation dose in a whole-body PET/CT examination without significantly sacrificing image quality.

  10. Congenital intrahepatic arterioportal and portosystemic venous fistulae with jejunal arteriovenous malformation depicted on multislice spiral CT

    International Nuclear Information System (INIS)

    Chae, Eun Jin; Goo, Hyun Woo; Yoon, Chong Hyun; Kim, Seong-Chul

    2004-01-01

    We report a symptomatic infant with very rare congenital arterioportal and portosystemic venous fistulae in the liver. Multislice CT after partial transcatheter embolisation revealed not only the complicated vascular architecture of the lesion, but also an incidental jejunal arteriovenous malformation which explained the patient's melena. The patient underwent ligation of the hepatic artery and resection of the jejunal arteriovenous malformation. Postoperative multislice CT clearly demonstrated the success of the treatment. (orig.)

  11. Contrast-Enhanced Ultrasound (CEUS for Echographic Detection of Hepato Cellular Carcinoma in Cirrhotic Patients Previously Treated with Multiple Techniques: Comparison of Conventional US, Spiral CT and 3-Dimensional CEUS with Navigator Technique (3DNav CEUS

    Directory of Open Access Journals (Sweden)

    Francesco Giangregorio

    2011-03-01

    Full Text Available A commercially available technique named “NAVIGATOR” (Esaote, Italy easily enables a 3-D reconstruction of a single 2-D acquisition of Contrast Enhanced Ultrasound (CEUS imaging of the whole liver (with a volumetric correction thanks to the electromagnetic device of NAVIGATOR. Aim of the study was to evaluate this “panoramic” technique in comparison with conventional US and spiral CT in the detection of new hepatic lesions. 144 cirrhotic patients (previously treated for hepato cellular carcinoma (HCC in follow-up with detection of 98 new nodules (N, 28 multinodular (Nmulti, 14 loco-regional regrowth (LR 94 efficaciously treated without new nodules (neg and four multinodular without new nodules, were submitted to 200 examinations with this new technique from November 2008 to November 2009. 3DNavCEUS was performed using SonoVue (Bracco, as contrast agent, and a machine (Technos MPX, Esaote. Spiral CT and 3DNav CEUS were performed in the same month during follow up. Sens.,Spec.,diagn.-Acc.,PPV and NPV were evaluated; comparison and differences between the techniques were obtained with chi-square (SPSS release-15. Final diagnosis was: 98 new lesions (N (one to three, 28 multinodular HCC (Nmulti and 14 loco-regional regrowth (LR; in 94 no more lesions were observed during follow-up; conventional US obtained: 58 N (+18 multinodularN and 8 LR, 40 false negative (+10 Nmulti and 6 LR (sens:59.2, spec:100%, Diagn Accur:73.6, PPV:100; NPV:70.1; spiral CT obtained: 84N (+26-multinodularN and 14-LR, 14 false-negative (+2-Nmulti, and one false-positive (sens:85.7, spec:97.9%, Diagn Accur:90.9, PPV:97.7; NPV:86.8; 3DNAV obtained: 92N (+28 multinodularN and 14LR, 6 false-negative, and two false-positives (sens:93.9, spec:97.9%, Diagn Accur:95.6, PPV:97.9; NPV:93.9. 3-DNav CEUS is significantly better than US and almost similar to spiral CT for detection of new HCC. This technique, in particular, showed the presence of lesions even in the cases not

  12. Contrast-Enhanced Ultrasound (CEUS) for Echographic Detection of Hepato Cellular Carcinoma in Cirrhotic Patients Previously Treated with Multiple Techniques: Comparison of Conventional US, Spiral CT and 3-Dimensional CEUS with Navigator Technique (3DNav CEUS)

    Energy Technology Data Exchange (ETDEWEB)

    Giangregorio, Francesco [Department of Gastroenterology, Guglielmo da Saliceto Hospital, Via Taverna 49, Piacenza 29121 (Italy)

    2011-03-30

    A commercially available technique named “NAVIGATOR” (Esaote, Italy) easily enables a 3-D reconstruction of a single 2-D acquisition of Contrast Enhanced Ultrasound (CEUS) imaging of the whole liver (with a volumetric correction thanks to the electromagnetic device of NAVIGATOR). Aim of the study was to evaluate this “panoramic” technique in comparison with conventional US and spiral CT in the detection of new hepatic lesions. 144 cirrhotic patients (previously treated for hepato cellular carcinoma (HCC)) in follow-up with detection of 98 new nodules (N), 28 multinodular (Nmulti), 14 loco-regional regrowth (LR) 94 efficaciously treated without new nodules (neg) and four multinodular without new nodules, were submitted to 200 examinations with this new technique from November 2008 to November 2009. 3DNavCEUS was performed using SonoVue (Bracco), as contrast agent, and a machine (Technos MPX, Esaote). Spiral CT and 3DNav CEUS were performed in the same month during follow up. Sens.,Spec.,diagn.-Acc.,PPV and NPV were evaluated; comparison and differences between the techniques were obtained with chi-square (SPSS release-15). Final diagnosis was: 98 new lesions (N) (one to three), 28 multinodular HCC (Nmulti) and 14 loco-regional regrowth (LR); in 94 no more lesions were observed during follow-up; conventional US obtained: 58 N (+18 multinodularN and 8 LR), 40 false negative (+10 Nmulti and 6 LR) (sens:59.2, spec:100%, Diagn Accur:73.6, PPV:100; NPV:70.1); spiral CT obtained: 84N (+26-multinodularN and 14-LR), 14 false-negative (+2-Nmulti), and one false-positive (sens:85.7, spec:97.9%, Diagn Accur:90.9, PPV:97.7; NPV:86.8); 3DNAV obtained: 92N (+28 multinodularN and 14LR), 6 false-negative, and two false-positives (sens:93.9, spec:97.9%, Diagn Accur:95.6, PPV:97.9; NPV:93.9). 3-DNav CEUS is significantly better than US and almost similar to spiral CT for detection of new HCC. This technique, in particular, showed the presence of lesions even in the cases not

  13. Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT. Editor`s note

    Energy Technology Data Exchange (ETDEWEB)

    Coakley, F.V. [Abdominal Imaging Section, Department of Radiology, University of California, San Francisco, CA (United States); Cohen, M.D. [Department of Radiology, Riley Hospital for Children, Indianapolis, IN (United States); Waters, D.J. [Department of Veterinary Clinical Sciences, Purdue University, West Lafayette, IN (United States); Davis, M.M. [Department of Pathology, Riley Hospital for Children, Indianapolis, IN (United States); Karmazyn, B. [Department of Radiology, Riley Hospital for Children, Indianapolis, IN (United States); Gonin, R. [Division of Biostatistics, Department of Medicine, Riley Hospital for Children, Indianapolis, IN (United States); Hanna, M.P. [Division of Biostatistics, Department of Medicine, Riley Hospital for Children, Indianapolis, IN (United States)

    1997-07-01

    Background. CT of the chest for suspected pulmonary metastases in adults is generally performed using a breath-hold technique. The results may not be applicable to young children in whom breath-holding may be impossible. Objective. Determine the effect of breathing on the accuracy of pulmonary metastasis detection by spiral CT (SCT). Materials and methods. Prior to euthanasia four anesthetized dogs with metastatic osteosarcoma underwent SCT with a collimation of 5 mm and a pitch of 2, during both induced breath-hold and normal quiet breathing. Images were reconstructed as contiguous 5-mm slices. Macroscopically evident metastases were noted at postmortem. Hard-copy SCT images were reviewed by ten radiologists, each of whom circled all suspected metastases. SCT images were compared with postmortem results to determine true and false positives. Results. The pathologist identified 132 macroscopically evident pulmonary metastases. For metastasis detection, there was no significant difference between breath-hold SCT and breathing SCT. Conclusion. In our animal model, SCT can be performed during normal resting breathing without significant loss of accuracy in the detection of pulmonary metastases. (orig.). With 3 tabs.

  14. Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT. Editor's note

    International Nuclear Information System (INIS)

    Coakley, F.V.; Cohen, M.D.; Waters, D.J.; Davis, M.M.; Karmazyn, B.; Gonin, R.; Hanna, M.P.

    1997-01-01

    Background. CT of the chest for suspected pulmonary metastases in adults is generally performed using a breath-hold technique. The results may not be applicable to young children in whom breath-holding may be impossible. Objective. Determine the effect of breathing on the accuracy of pulmonary metastasis detection by spiral CT (SCT). Materials and methods. Prior to euthanasia four anesthetized dogs with metastatic osteosarcoma underwent SCT with a collimation of 5 mm and a pitch of 2, during both induced breath-hold and normal quiet breathing. Images were reconstructed as contiguous 5-mm slices. Macroscopically evident metastases were noted at postmortem. Hard-copy SCT images were reviewed by ten radiologists, each of whom circled all suspected metastases. SCT images were compared with postmortem results to determine true and false positives. Results. The pathologist identified 132 macroscopically evident pulmonary metastases. For metastasis detection, there was no significant difference between breath-hold SCT and breathing SCT. Conclusion. In our animal model, SCT can be performed during normal resting breathing without significant loss of accuracy in the detection of pulmonary metastases. (orig.). With 3 tabs

  15. The comparative study of various oral contrast media in 3D display of gastric lesions in spiral CT

    International Nuclear Information System (INIS)

    Wu Dong; Zhou Kangrong; Peng Weijun

    2001-01-01

    Objective: To optimize the oral contrast media in three-dimensional display of gastric lesions. Methods: 41 cases were randomly divided into 3 groups according to different oral contrast media administered: No. 1 air contrast group (n = 17), No. 2 fat emulsion group (n = 7) and No. 3 positive contrast group (n = 25). The 3D CT images were reconstructed using MPR, SSD, RaySum display and virtual endoscopic techniques, and compared with gastric endoscopy and/or conventional barium study. Results: The detectability of gastric lesions using fat emulsion and air contrast was 42.8%(3/7) and 80.0%(20/25), respectively, both were significantly lower than that using positive contrast (100%, 30/30) (x 2 = 19.22, P 2 = 6.60, P 2 = 17.04, P < 0.01). Conclusion: It is very important to choose the appropriate oral contrast media for 3D display of gastric lesions in spiral CT, the positive contrast agent is the optimal choice

  16. Malignant hepatic tumors treated with percutaneous radio-frequency ablation: Comparison between contrast-enhanced color Doppler ultrasound and spiral CT in evaluating the therapeutic efficacy

    International Nuclear Information System (INIS)

    Yoon, Jung Hee; Han, Sang Suk; Cha, Sung Sook

    2002-01-01

    To compare contrast-enhanced color Doppler ultrasound (CECDUS) with spiral CT in the evaluation of the therapeutic efficacy of malignant hepatic tumors after radio-frequency ablation (RFA). During a recent 2 year period (April 1999 to March 2001). One hundred fifteen hepatic tumors (95 hepatocellular carcinomas and 20 metastases; mean diameter, 2.7 cm) from 83 consecutive patients (60 men and 23 women; mean age, 57 years) that were treated with RFA were included in this study. Both CECDUS and two-or three phase spiral CT were performed a day after RFA as the immediate follow-up study in most cases. Afterward, both imaging studies were alternatively performed on monthly basis, but when incomplete ablation was suspected on one follow-up imaging study, the other imaging study was performed within a week for comparison. For ultrasound contrast agent, a suspension of 2.5 g or 4.0 g Levovist (Schering AG, Berlin, Germany) with a concentration of 300 mg/mL was used. For evaluating the therapeutic efficacy, the presence of viable portion, either residual or recurrent, within the ablated tumor was determined on each imaging study. The criteria for viable portion were defined as focal or irregular enhancement at the periphery of the ablated tumor on the arterial or portal phase spiral CT images and intratumoral vascularities on CECDUS. The correspondence rate between both imaging studies was assessed to compare the diagnostic accuracy of both studies in evaluating a residual or recurrent tumor. In addition, their imaging findings were analyzed. Analyzing both imaging findings of 116 malignant hepatic tumors, the correspondence rate between CECDUS and CT obtained after 116 times of imaging studies was 91.4% (106/116). For the diagnosis of residual or recurrent tumors, the sensitivity, specificity and diagnostic accuracy of spiral CT were 71%, 99%, and 94%, respectively, while those of CECDUS were 87%, 99%, and 97%, respectively. As the immediate follow-up study, CECDUS seemed

  17. Evaluation of head examinations produced with a mobile CT unit.

    Science.gov (United States)

    Matson, M B; Jarosz, J M; Gallacher, D; Malcolm, P N; Holemans, J A; Leong, C; Seed, P T; Ayers, A B; Rankin, S C

    1999-07-01

    Recent years have seen the development of mobile CT units, designed for use in operating theatres, intensive care units and accident and emergency departments. One such unit is the Tomoscan M (Philips, Utrecht, The Netherlands). It operates with a maximum tube voltage of 130 kV, and a maximum tube current of only 50 mA. This study tested whether acceptable quality CT images of the brain could be produced on the mobile unit with these parameters. 44 consecutive normal head examinations performed on the mobile scanner were compared with 35 examinations from two conventional CT units. Two independent readers scored the examinations for noise and artefact. CT dose index (CTDI) values for the three CT units were obtained in free air as an estimate of patient dose. Differences in artefact score between CT units were generally small, but noise scores were worse when using the Tomoscan M with a 2 s slice time. The lowest CTDI values were obtained with the Somatom DRH (Siemens, Erlangen, Germany) unit and the highest with the SR 7000 (Philips, Utrecht, The Netherlands), with values from Tomoscan M, in all except one case, falling between these values for the protocols used in the study. The measured scattered radiation doses from the Tomoscan M are presented.

  18. Perforated colorectal neoplasms: Correlation of clinical, barium, and CT examinations

    International Nuclear Information System (INIS)

    Hulnick, D.H.; Megibow, A.J.; Gordon, R.; Balthazar, E.J.

    1986-01-01

    Findings on clinical, barium enema, and CT examinations in 24 patients with perforated colorectal neoplasms were retrospectively reviewed. In 12 patients with fever and leukocytosis, the clinical diagnoses were diverticulitis (n=8), appendicitis (n=2), pelvic inflammatory disease (n=2), and perforation of a known carcinoma (n=1). In 12 nontoxic patients, the clinical diagnoses were malignancy (n=8), obstruction (n=3) and an abdominal mass (n=1). In 18 barium enema examinations, the radiologic impression was uncomplicated carcinoma (n=9), perforated carcinoma (n=6), and diverticulitis (n=3). Twenty-two CT examinations revealed pericolic inflammation in all cases and macroperforation in 12. The primary tumor was evident in 14 patients, liver metastases were found in six, and ascites was present in three. CT findings influenced the management of patients initially suspected of having inflammatory conditions

  19. Estimates of effective dose in adult CT examinations

    International Nuclear Information System (INIS)

    Mohamed, Mustafa Awad Elhaj.

    2015-12-01

    The goal of study was to estimate effective dose (E) in adult CT examinations for Toshiba X64 slice using CT. Exp version 2.5 software in Sudan. Using of CT in medical diagnosis delivers radiation doses to patients that are higher than those from other radiological procedures. lack of optimized protocols could be an additional source of increased dose in developing countries. In order to achieve these objectives, data of CT-scanner has been collected from three hospitals ( ANH, ZSH and MMH). Data collected included equipment information and scan parameters for individual patients, who were used to asses. 300 adult patients underwent head, chest, abdomen-pelvis and peivis CT examinations. The CT1 w , CTD1 v ol, DLP, patient effective dos and organ doses were estimated, using CT exposure parameters and CT Exp version 2.5 software. A large variation of mean effective dose and organ doses among hospitals was observed for similar CT examinations. These variations largely originated from different CT scanning protocols used in different hospitals and scan length. The mean effective dose in this study in the Brain, PNS, Chest, pulmonary, Abdomen-pelvis, Pelvis, KUB and CTU were 3.2 mSv, 2.6 mSv, 18.9 mSv 17.6 mSv 27.1 mSv, 11.2 mSv, 9.6 mSv and 23.7 mSv respectively, and organ equivalent, doses presented in this study in this study for the eye lens (for head), lungs and thymus ( for chest) , liver, kidney and small intest ( for abdomen t-pelvis), bladder, uterus and gonads ( for pelvis), were 62.9 mSv, 39.5 mSv, 34.1 mSv, 53.9 mSv, 52.6 mSv, 58.1 mSv, 37 mSv, and 34.6 mSv, respectively. These values were mostly comparable to and slightly higher than the values of effective doses reported from similar studies the United Kingdom, Tanzania, Australia, Canada and Sudan. It was concluded that patient effective dose and organ doses could be substantially minimized through careful selection of scanning parameters based on clinical indications of study, patient size, and body

  20. Aortic non communicating dissections. A study with helical CT; Studio dell'ematoma intramurale aortico. Aspetti con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Midiri, M.; Strada, A.; Stabile Ianora, A.A.; Rotondo, A.; Angelelli, G. [Bari Univ., Bari (Italy). Dipt. di Medicina Interna e Medicina Pubblica, Sez. di Diagnostica per Immagini; Scialpi, M. [Ospedale SS. Annunziata, Taranto (Italy); D' Agostino, D.; De Luca Tupputi Schinosa, L. [Bari Univ., Bari (Italy). Dipt. Emergenze Trapianto d' Organo, Sez. di Cardiochirurgia

    2000-09-01

    The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low density on enhanced images in all patients. Thickening was eccentric in 14/18 patients and concentric in 4/18 only; it always exceeded 4 mm. It was found some intimal calcifications in 8 patients and hemo thorax and/or hemo mediastinum in 9 patients. A patient with type A hematoma died of cardiac tamponade a few hours after CT diagnosis. Six patients (5 type B and 1 type A) underwent anti-hypertensive treatment and radiological follow-up. Eleven patients (6 type A and 5 type B) underwent prosthesis replacement and 5 of them (3 type A and 2 type B) died of postoperative complications. In the 5 type B patients surgery was performed because of treatment-resistant pain and of the onset of ischemic complications to abdominal organs caused by involvement of the main collateral branches of the aorta. One patient with type A hematoma was submitted to drug treatment because it was judged unresectable. Intramural hematoma of the aorta is a distinct pathological entity, which should not be

  1. Patient doses in chest CT examinations: Comparison of various CT scanners

    OpenAIRE

    Božović Predrag; Ciraj-Bjelac Olivera; Aranđić Danijela; Hadnađev Darka; Stojanović Sanja

    2013-01-01

    This paper presents results from study on patient exposure level in chest CT examinations. CT scanners used in this study were various Siemens and General Electric (GE) models. Data on patient doses were collected for adult and pediatric patients. Doses measured for adult patients were lower then those determined as Diagnostic Reference Levels (DRL) for Europe, while doses for pediatric patients were similar to those found in published data. As for the manu...

  2. Low-dose 16-slice spiral CT thoracic angiography using Z-axis modulation

    International Nuclear Information System (INIS)

    Li Huimin; Yu Hong; Xiao Xiangsheng; Yu Lingwei

    2011-01-01

    Objective: To explore the feasibility of low dose in MSCT thoracic angiography using Z-axis modulation. Methods: The consecutive 60 patients were averagely divided into 3 groups and underwent thoracic angiography with a Toshiba Aquilion 16 scanner. The whole chest acquisition was commenced in automatic exposure control with Z-axis modulation 20-25 seconds after the contrast material was administered at the rate of 3.5-4.0 ml/s. With the noise index (SD) as the variable, three study groups were classified as A (SD=12), B (SD=15), and C (SD=18). The mAs value per slice and the number of slices were recorded. The noises and artifacts of the axial images and the acceptability of CT angiogram were evaluated. The difference among the groups was compared by using ANOVA or nonparametric Kruskal-Wallis test. The threshold of the P value was 0.05. Results: The mean mAs value (46.4± 15.6) mAs in group A was the highest but the SD value (21.6±7.7) was the lowest. The mean mAs value (37.0±13.5) and the SD value (24.0±5.4) in group B were the mediate. The mean mAs value (20.7± 6.3) mAs in group C was the lowest but the SD value (30.7±6.9) was the highest (H=31.390, P= 0.000). The middle slice images in all patients had the smallest mAs (40.9, 31.3, 17.1 for group A, B, C, respectively; F=9.578, H=22.230, F=21.180, P=0.000) and SD values (16.3, 20.0, 25.4 for group A, B, C, respectively; H=28.982, H=20.824, H=24.396, P=0.000). The acceptability of CT angiogram in all patients was excellent. The CT value of descending aorta in group A, B, and C was (335±85) HU, (334±56) HU, and (427±63) HU, respectively. Conclusion: Low dose in MSCT thoracic angiography using Z-axis modulation is feasible. We can use low dose (20 mAs, etc.) for CT angiography when the contrast is significant. (authors)

  3. Extravasation of contrast medium during CT examination: An ...

    African Journals Online (AJOL)

    Introduction: extravasation is an adverse reaction to intravenous injection of contrast medium (CM) during CT examination. The objectives of this study are to determine the frequency, management and outcomes of extravasations and to assess risk factors for extravasation. Methods: every incident of extravasation which ...

  4. Choice ofoptimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Fang Hong; Song Yunlong; Bi Yongmin; Wang Dong; Shi Huiping; Zhang Wanshi; Zhu Hongxian; Yang Hua; Ji Xudong; Fan Hongxia

    2008-01-01

    Objective: To evaluate the efficacy of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning. Methods: MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups. In group A (n=59), the scan delay time was set according to the subjective experiences of operators; in group B (n=128), the scan delay time was determined by test bolus technique. Abdominal aorta and superior mesenteric, vein were selected as target blood vessels, and 50 HU was set as enhancement threshold value. 20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained, then HA-PV scanning delay time were calculated respectively. The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion. Results: For hepatic artery phase, the images of group A are: excellent in 34 (58%), good in 17 (29%), and poor in 8 (13%), while those of group B are excellent in 128(100%), good in 0(0%), and poor in 0(0%). For portal vein phase, the images of group A are: excellent in 23 (39%), good in 27 (46%), and poor in 9 (15%), while those of group B are excellent in 96 (75%), good in 28 (22%), and poor in 4 (3%) respectively. There was statistically significant difference between the ratios of image quality in group A and group B (χ 2 =14.97, 9.18, P< 0.05). Conclusion: Accurate scan delay time was best determined by using test bolus technique, which can improve the image quality of liver angiography and multi-phase scanning. (authors)

  5. Primitive experience of three dimensional multi-slice spiral CT angiography for the follow-up of intracranial aneurysm clipping

    International Nuclear Information System (INIS)

    Yang Yunjun; Chen Weijian; Hu Zhangyong; Wu Enfu; Wang Meihao; Zhuge Qichuan; Zhongming; Cheng Jingliang; Ren Cuiping; Zhang Yong

    2008-01-01

    Objective To evaluate multi-slice three-dimensional CT angiography (MS 3D-CTA) for the follow-up of intracranial aneurysm clipping. Methods: MS 3D-CTA of 16 patients with intracranial aneurysm clipping were retrospectively analyzed. The patients were scanned on a 16-slice spiral CT (GE Lightspeed pro). Volume rendering(VR), thin maximum intensity projection(thin MIP) and multi-planar reconstruction (MPR) were employed in image postprocessing in all cases. Results: There were 17 clips in the 16 patients with aneurysm clipping. Six clips were located at the posterior communicating artery, 5 at the anterior communicating artery, 4 at the middle cerebral artery, and the remaining 2 clips were located at the pericallosal artery, in 1 patient. There were no abnormalities found in the aneurysm clipping region in 7 cases by MS 3D- CTA. There were residual aneurysm in 2 cases, parent artery stenosis in 4 cases, and artery spasm in 3 eases. There was no parent artery occlusion and clip displacement in all cases. VR showed excellent 3D spacial relations between the clip and parent artery in 12 cases, and showed good relations in 3 cases. The 1 case with 2 clips in the pericallosal artery showed heavy beam-hardening artifacts. The size and shape of aneurysm clips were clearly depicted by MPR and thin MIP, while 3D spacial relation of aneurysm clip and parent artery were poorly showed. Conclusion: MS 3D-CTA is a safe and efficient method for the follow-up of intracranialaneurysm clipping. Combined VR with MPR or thin MIP can well reveal postoperative changes after aneurysm clipping. (authors)

  6. Is primary care access to CT brain examinations effective?

    International Nuclear Information System (INIS)

    Benamore, R.E.; Wright, D.; Britton, I.

    2005-01-01

    AIM: Primary care access to CT head examinations could enable common neurological conditions to be managed within primary care. Outcome data from the first 8 years of a local service were used to identify effective referral criteria. METHODS: Primary care head CT results from 1 March 1995 to 31 October 2003 were categorized as normal, incidental or significant findings. Normal reports were cross-referenced for referral to secondary care. Case notes with incidental or significant CT findings were reviewed for secondary care attendance and outcome. RESULTS: Records of 1403/1645 CT head examinations (85%) were available for review. Of these 1403, 951 (67.8%) returned normal findings, 317 (22.6%) incidental findings and 135 (9.6%) significant findings. The commonest indication for referral was investigation of headaches (46.6%). Of the total 533 patients under 50 years of age, 13 (2.4%) yielded significant findings and all 13 showed other features in addition to headache. Of 314 cases presenting with focal neurology, 83 (26.4%) showed significant findings. 314 patients were referred from primary to secondary care. 189 had normal scans and 74 had findings described as incidental. 60% of secondary care referrals were for normal CT scans. In patients with focal neurology, 90 of 314 were referred, allowing 71% to be managed in primary care. Yield was also 0% for headaches, dizziness, visual disturbance or nausea and vomiting. CONCLUSION: Primary care access to CT brain examinations is effective for patients with focal neurology, neurological symptoms or a known malignancy, but not for patients aged less than 50 years, or with uncomplicated headaches, dizziness or diplopia

  7. A comparison between ventilation/perfusion scintigraphy and multislice spiral CT in the diagnosis of chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Fang Wei; Wang Feng; He Zuoxiang; Lu Jinguo; Lv Bing; He Jianguo; Liu Zhihong

    2008-01-01

    Objective: Chronic thromboembolic pulmonary hypertension (CTEPH) is one of the important causes of pulmonary hypertension with poor prognosis. Several imaging techniques had been used to identify CTEPH. The aim of this study was to assess the reliability of ventilation/perfusion (V/Q) scintigraphy and multislice spiral CT pulmonary angiography (CTPA) in the diagnosis of chronic thromboembolic pulmonary hypertension, and the concordance rate (or 'agreement' as in the original article) between the two techniques. Methods: Forty-nine in-patients with pulmonary hypertension without history of con- genital heart disease, valvular heart disease and acute pulmonary embolism were included in this study. All these patients underwent V/Q scintigraphy as well as CTPA for detecting CTEPH. The final diagnosis was confirmed by pulmonary angiograpy. The results of V/Q scintigraphy and CTPA were compared with the χ 2 test. Results: The sensitivity, specificity and accuracy of V/Q scintigraphy in diagnosis of CTEPH was 100.0% (17/17), 71.9% (23/32) and 81.6% (40/49), respectively, and those of CTPA was 94.1% (16/17), 81.2% (26/32) and 85.7% (42/49), respectively. The concordance rate was 75.5% (37/49, Kappa=0.513), no statistically significant difference (χ 2 =0.75, P > 0.05 ) was found between V/Q scintigraphy and CTPA. Conclusion: Both V/Q scintigraphy and CTPA are reliable to diagnose CTEPH. (authors)

  8. Multi-detector spiral CT study of the relationships between pulmonary ground-glass nodules and blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Feng; Li, Ming; Ge, Xiaojun; Ren, Qingguo; Hua, Yanqing [Huadong Hospital Fudan University, Department of Radiology, Shanghai (China); Zheng, Xiangpeng [Huadong Hospital Fudan University, Department of Radiation Oncology, Shanghai (China); Chen, Yan [Huadong Hospital Fudan University, Department of Pathology, Shanghai (China); Lv, Fangzhen [Huadong Hospital Fudan University, Department of Thoracic Surgery, Shanghai (China)

    2013-12-15

    To investigate the relationships between pulmonary ground-glass nodules (GGN) and blood vessels and their diagnostic values in differentiating GGNs. Multi-detector spiral CT imaging of 108 GGNs was retrospectively reviewed. The spatial relationships between GGNs and supplying blood vessels were categorized into four types: I, vessels passing by GGNs; II, intact vessels passing through GGNs; III, distorted, dilated or tortuous vessels seen within GGNs; IV, more complicated vasculature other than described above. Relationship types were correlated to pathologic and/or clinical findings of GGNs. Of 108 GGNs, 10 were benign, 24 preinvasive nodules and 74 adenocarcinomas that were pathologically proven. Types I, II, III and IV vascular relationships were observed in 9, 58, 21 and 20 GGNs, respectively. Type II relationship was the dominating relationship for each GGN group, but significant differences were shown among them. Correlation analysis showed strong correlation between invasive adenocarcinoma and type III and IV relationships. Subgroup analysis indicated that type III was more commonly seen in IAC with comparison to type IV more likely seen in MIA. Different GGNs have different relationships with vessels. Understanding and recognising characteristic GGN-vessel relationships may help identify which GGNs are more likely to be malignant. (orig.)

  9. Comparative study of paranasal sinus between 16-slice spiral CT coronary reforming imagines and scanning images

    International Nuclear Information System (INIS)

    Lei Ziqiao; Han Ping; Yu Jianming; Chen Yan; Shi Heshui; Liu Yonghua; Yu Qun; Wu Hongying

    2007-01-01

    Objective: To explore the effect of different scanning methods and different constructive arithmetic on displaying the anatomy of ostiomeatal complex (OMC). Methods: Fifty-six patients undergoing paranasal sinus CT were divided into normal group (34 cases) and inflammation group (22 cases). According to scanning methods, all the cases reconstructed with soft tissue arithmetic were divided into coronary reforming group and coronary scanning group. Among 56 cases, 18 normal cases and 16 inflammation cases were reconstructed using high resolution arithmetic simultaneously. The imaging quality of OMC was assessed with different scanning methods and different constructive arithmetic. Results: There are no significant difference between coronary reforming images and coronary scanning images in two groups. There are significant difference between high resolution arithmetic and soft tissue arithmetic in normal group, but not in inflammation group. Conclusions: The information of axial images and coronary reforming images with 16-slice CT is superior to coronary scanning images on displaying the anatomy of OMC. High resolution arithmetic is better in displaying the tiny structure of OMC than soft tissue arithmetic in normal group. (authors)

  10. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  11. The selection of window width and levels for measuring the airway dimensions with spiral CT scan: an experimental study in Japanese white big-ear rabbits

    International Nuclear Information System (INIS)

    Han Xinwei; Lu Huuibing; Wu Gang; Ma Ji; Wang Nan; Si Jiangtao

    2009-01-01

    Objective: To investigate the optimal window width and window level for measuring the airway dimensions with spiral CT scan in Japanese white big-ear rabbits so as to lay the foundation for airway stenting in animal experiments. Methods: Multi-slice spiral CT scanning of cervico-thoracic region was performed in 30 healthy adult Japanese white big-ear rabbits, the anteroposterior and transversal diameter of the thoracic trachea, the anteroposterior diameter of the right and left bronchus were measured with lung window, mediastinum window and special fat window separately. The revealing rate of the tracheal wall and the measuring results in different windows and levels were recorded and compared with the anatomical data. The differences of the relevant data were statistically analyzed. Results: With lung window, the tracheal wall was well demonstrated, but the relevant data were smaller than that with mediastinum window. With mediastinum window, the data were bigger and the tracheal wall border appeared blurred. The results obtained with fat window were close to the actual anatomical data. Conclusion: For accurately measuring the anteroposterior and transversal diameter of the thoracic trachea in Japanese white big-ear rabbits with multi- slice spiral CT scan, fat window should be adopted, which is helpful for the preparation of tracheal and bronchial stents. (authors)

  12. Screenings of lung cancer with low dose spiral CT: results of a three year pilot study and design of the randomised controlled trial Italung-CT; Screening della neoplasia polmonare con TC spirale a bassa dose: risultati di uno studio pilota triennale e disegno dello studio clinico randomizzato Italung-CT

    Energy Technology Data Exchange (ETDEWEB)

    Picozzi, Giulia [Firenze Univ., Firenze (Italy). Radiodiagnostica I-Dipartimento di Fisiopatologia Clinica; Paci, Enrico [Azienda Ospedaliera Universitaria di Careggi, Firenze (Italy). Unita' di Epidemiologia Clinica e Descrittiva Centro per lo Studio e la Prevenzione Oncologica; Lopes Pegna, Andrea [Azienda Ospedaliera Universitaria di Careggi, Firenze (Italy). U.O. Pneumologia] [and others

    2005-02-01

    Purpose: To report the results of a three-year observational pilot study of lung cancer screening with low dose computed tomography (CT) and to present the study design of a randomised clinical trial named as Italung CT. Materials and methods: Sixty (47 males and 13 females, mean age 64{+-}4.5 years) heavy smokers (at least 20 packs-year) underwent three low-dose spiral CT screening tests one year apart on a single slice or multislice CT scanner. Indeterminate nodules were managed according to the recommendations of the Early Lung Cancer Action Project. Results: Indeterminate nodules were observed in 33 (55%) of the subjects (60% at the baseline screening test, 24% at the first annual test and 16% at the second annual test). The size of the largest indeterminate nodule was <5mm in diameter in 20 subjects. 10 of whom showed the nodule at the baseline test. Forty-five subjects (75%) completed the first annual test and 42 (70%) the second annual test. One (1.6%) prevalent lung cancer (adenosquamous carcinoma) and one (2.2%) incident lung cancer (small cell cancer at the first annual examination) were observed, as well as pulmonary localisation of Hodgkin's lymphoma (at the second annual test). In addition, one subject underwent lung surgery for a chondromatous hamartoma. Conclusions: The results of the pilot study are substantially in line with those of other observational studies of greater sample size. This justifies optimism about the reliability of the results in the screened arm of the Italung Ct trial which hast just began. [Italian] Scopo: Riportare i risultati di uno studio pilota osservazionale di screening della neoplasia polmonare con TC a bassa dose della durata di tre anni e presentare il disegno dello studio clinico randomizzato Italung-CT. Materiale e metodi: Sessanta (47 uomini e 13 donne, eta' media 64{+-}4,5 anni) forti fumatori (almeno 20 pacchetti/anno) sono stati sottoposti ad un esame basale e a due controlli annuali con TC single o

  13. CT and MR findings in retinoblastoma : correlation with histopathologic examination

    Energy Technology Data Exchange (ETDEWEB)

    Park, Son Won; Han, Moon Hee; Chi, Je G.; Yu, Young Suk; Kim, Yeon Mee; Chung, Jin Haeng; Yu, In Kyu; Chang, Kee Hyun; Yeon, Kyung Mo [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-06-01

    To evaluate histopathologic correlation of the component of the lesion on CT and MR of retinoblastomas. Gross pathologic findings of 24 enucleated eyeballs in 24 patients with retinoblastomas were compared with preoperative CT (n=19) and MR (n=5) findings. In eight eyeballs, in which there were findings other than mass, histopathologic findings were reviewed and correlated with image findings. Retinal detachment and subretinal hemorrhage which were not detected on CT were demonstrated in two of eight eyeballs on histopathologic examination. In one eyeball, retinal detachment and subretinal effusion were detected on both CT and in a pathologic specimen. In two eyeballs with peripheral heterogeneous MR enhancement of the masses, tumor necrosis and calcification were demonstrated in the central non-emhancing portion of the mass, In two eveballs, linear soft tissue along the retina apart from the main mass were revealed as tumor spread along the retinal surface. In one patient, retinal thickening on MR was presumed to be an MR artifact and no lesion was found in the gross specimen. On CT, retinal detachment and subretinal hemorrhage associated with retinoblastoma can mimic mass, and tumor spread along the retinal surface can be seen as a linear retinal lesion. On MR, tumor necrosis and calcification can be a cause of heterogeneous enhancement.

  14. CT and MR findings in retinoblastoma : correlation with histopathologic examination

    International Nuclear Information System (INIS)

    Park, Son Won; Han, Moon Hee; Chi, Je G.; Yu, Young Suk; Kim, Yeon Mee; Chung, Jin Haeng; Yu, In Kyu; Chang, Kee Hyun; Yeon, Kyung Mo

    1997-01-01

    To evaluate histopathologic correlation of the component of the lesion on CT and MR of retinoblastomas. Gross pathologic findings of 24 enucleated eyeballs in 24 patients with retinoblastomas were compared with preoperative CT (n=19) and MR (n=5) findings. In eight eyeballs, in which there were findings other than mass, histopathologic findings were reviewed and correlated with image findings. Retinal detachment and subretinal hemorrhage which were not detected on CT were demonstrated in two of eight eyeballs on histopathologic examination. In one eyeball, retinal detachment and subretinal effusion were detected on both CT and in a pathologic specimen. In two eyeballs with peripheral heterogeneous MR enhancement of the masses, tumor necrosis and calcification were demonstrated in the central non-emhancing portion of the mass, In two eveballs, linear soft tissue along the retina apart from the main mass were revealed as tumor spread along the retinal surface. In one patient, retinal thickening on MR was presumed to be an MR artifact and no lesion was found in the gross specimen. On CT, retinal detachment and subretinal hemorrhage associated with retinoblastoma can mimic mass, and tumor spread along the retinal surface can be seen as a linear retinal lesion. On MR, tumor necrosis and calcification can be a cause of heterogeneous enhancement

  15. Optimization of pediatric examinations in a multislice helical CT

    International Nuclear Information System (INIS)

    Ombada, T. H. A.

    2010-12-01

    Radiological protection of pediatric patients undergoing medical imaging procedures involving ionizing radiation has always received special attention. This is due to the fact that children have higher radiation sensitivity and increased likelihood for radiation-induced cancer manifesting in many more years of their life than adults. In computed tomography (CT), such attention is more important because of the potential of relatively higher radiation doses during these procedures. Such high doses are possible with technological developments where volume scanning using faster multi-slice CT systems is now preferred to conventional CT equipment. The task of this study is to assess the optimization of paediatric doses in multi-slice CT examinations. It was carried out in Alrebat University Hospital for 31 pediatric patients, 43 examinations (27 head examination and 16 body (chest, abdomen and pelvis) examinations). Data were collected for scan parameters (kV, m As, pitch, scan length, number of slices and slice thickness) and doses displayed in monitor (CTDI v ol and DLP) for head examinations and body (chest, abdomen and pelvis) examinations. For head CT, displayed CTDI v ol ranged from 1.56 to 69.12 mGy, calculated value from 2.10 to 70.93 mGy. Displayed DLP ranged from 53 to 1817 mGy.cm, calculated from 95.30 to 1532.16 mGy. cm. For body examination, the range of displayed CTDI from 1.63 to 3.92 mGy, calculated value from 2.22 to 5.34 mGy. Displayed DLP ranged from 34 to 194 mGy.cm, for calculated from 45.89 to 161.98 mGy. cm. The calculated values are in agreement with reference study dose values although there are some high values in this study for some examinations, this variation or difference may attribute to variation in pediatric ages (9 days- 15 years), scan length and m As values. There is variation between calculated and displayed values. more optimization for CT doses is needed. (Author)

  16. Computing effective doses to pediatric patients undergoing body CT examinations.

    Science.gov (United States)

    Huda, Walter; Ogden, Kent M

    2008-04-01

    The computation of patient effective doses to children is of particular interest given the relatively high doses received from this imaging modality, as well as the increased utilization of CT in all areas of medicine. Current methods for computing effective doses to children are relatively complex, and it would be useful to develop a simple method of computing pediatric effective doses for clinical purposes that could be used by radiologists and technologists. To obtain pediatric effective doses for body CT examinations by the use of adult effective doses obtained from effective dose (E) per unit dose length product (DLP) coefficients, and energy imparted to a child relative to an adult. Adult E/DLP coefficients were obtained at 120 kV using the ImPACT CT dosimetry spreadsheet. Patients were modeled as cylinders of water, and values of energy imparted to cylinders of varying radii were generated using Monte Carlo modeling. The amounts of energy imparted to the chest and abdomen of children relative to adults (R(en)) were obtained. Pediatric effective doses were obtained using scaling factors that accounted for scan length, mAs, patient weight, and relative energy imparted (R(en)). E/DLP values were about 16 microSv/mGy cm for males and about 19 microSv/mGy cm for females. R(en) at 120 kV for newborns was 0.35 for the chest and 0.49 for the abdomen. At constant mAs, the effective dose to 6-month-old patients undergoing chest CT examinations was found to be about 50% higher than that to adults, and for abdominal examinations about 100% higher. Adult effective doses can be obtained using DLP data and can be scaled to provide corresponding pediatric effective doses from body examinations on the same CT scanner.

  17. Estimation of absorbed dose of radiosensitive organs and effective sose in patients underwent abdominopelvic spiral CT scan using impact CT patient dosimetry

    Directory of Open Access Journals (Sweden)

    Ayoub Amirnia

    2017-05-01

    Full Text Available Background: Due to the presence of radiosensitive organs in the abdominopelvic region and increasing the number of requests for CT scan examinations, concerns about increasing radiation doses in patients has been greatly elevated. Therefore, the goal of this study was to determine the absorbed dose of radiosensitive organs and the effective dose in patients underwent abdominopelvic CT scan using ImPACT CT patient dosimetry Calculator (version 1.0.4, Imaging Performance Assessment on Computed Tomography, www.impactscan.org. Methods: This prospective cross-sectional study was conducted in Imam Reza Hospital from November to February 2015 February 2015 in the Imam Reza Hospital, in Urmia, Iran. The demographic and dosimetric information of 100 patients who underwent abdominopelvic CT scan in a 6-slice CT scanner were obtained through the data collection forms. The demographic data of the patients included age, weight, gender, and BMI. The dosimetric parameters included pitch value, CT dose volume index (CTDIvol, dose-length product (DLP, tube voltage, tube current, exposure time, collimation size, scan length, and scan time. To determine the absorbed dose of radiosensitive organs and also the effective dose in patients, ImPACT CT patient dosimetry calculator was used. Results: The results of this study demonstrated that the mean and standard deviation (SD of patients' effective dose in abdominopelvic CT scan was 4.927±0.164 mSv. The bladder in both genders had the greatest mean organ dose, which was 64.71±17.15 mGy for men and 77.56±18.48 mGy for women (P<0.001. Conclusion: The effective dose values of this examination are in the same range as previous studies, as well as International Commission on Radiological Protection (ICRP recommendations. However, the radiation dose from CT scan has the largest contribution to the medical imaging. According to the ALARA principle, it is recommended that the scan parameters, especially mAs, should be

  18. Effect of imaging parameters of spiral CT scanning on image quality for the dental implants. Visual evaluation using a semi-anthropomorphic mandible phantom

    International Nuclear Information System (INIS)

    Morita, Yasuhiko; Indou, Hiroko; Honda Eiichi

    2002-01-01

    The purpose of this study was to evaluate the effect of parameters of spiral CT scanning on the image quality required for the planning of dental implants operations. A semi-anthropomorphic mandible phantom which has artificial mandibular canals and teeth roots was used as a standard object for imaging. Spiral CT scans for the phantom settled in water phantom with diameters of 20 and 16 cm were performed. Visibility of the artificial mandibular canal made of a Teflon tube and gaps between tooth apex and canal in the mandibular phantom was evaluated for various combinations of the slice thickness, tables speeds, angles to the canal, and x-ray tube currents. Teeth roots were made of PVC (poly vinyl chloride). The artificial mandibular canal was clearly observed on the images of 1 mm slice thickness. At the same table speed of 2 mm /rotation, the images of thin slice (1 mm) were superior to that of thick slice (2 mm). The gap between teeth apex and canal was erroneously diagnosed on the images with table speeds of 3 mm/rotation. Horizontal scanning in parallel to the canal result in poor image quality for observation of mandibular canals because of the partial volume effect. A relatively high x-ray tube current (125 mA) at thin slice (1 mm) scanning was required for scanning the mandibular phantom in 20 cm water vessel. Spiral scanning with slice thickness of 1 mm and table speeds of 1 of 2 mm/rotation seemed to be suitable for dental implants. The result of this study suggested that diagnosis from two independent spiral scans with a different angle to the object was more accurate and more efficient than single spiral scanning. (author)

  19. The Spiral of Euroscepticism

    DEFF Research Database (Denmark)

    Galpin, Charlotte; Trenz, Hans-Jörg

    2017-01-01

    Media scholars have increasingly examined the effects of a negativity bias that applies to political news. In the ‘spiral of cynicism’, journalist preferences for negative news correspond to public demands for sensational news. We argue that this spiral of cynicism in EU news results in a ‘spiral...

  20. Value of 3D-Volume Rendering in the Assessment of Coronary Arteries with Retrospectively Ecg-Gated Multislice Spiral CT

    International Nuclear Information System (INIS)

    Mahnken, A.H.; Wildberger, J.E.; Dedden, K.; Schmitz-Rode, T.; Guenther, R.W.; Sinha, A.M.; Hoffmann, R.; Stanzel, S.

    2003-01-01

    Purpose: To assess the diagnostic value and measurement precision of 3D volume rendering technique (3D-VRT) from retrospectively ECG-gated multislice spiral CT (MSCT) data sets for imaging of the coronary arteries. Material and Methods: In 35 patients, retrospectively ECG-gated MSCT of the heart using a four detector row MSCT scanner with a standardized examination protocol was performed as well as quantitative X-ray coronary angiography (QCA). The MSCT data was assessed on segmental basis using 3D-VRT exclusively. The coronary artery diameters were measured at the origin of each main coronary branch and 1 cm, 3 cm and 5 cm distally. The minimum, maximum and mean diameters were determined from MSCT angiography and compared to QCA. Results: A total of 353 of 525 (67.2%) coronary artery segments were assessable by MSCT angiography. The proximal segments were more often assessable when compared to the distal segments. Stenoses were detected with a sensitivity of 82.6% and a specificity of 92.8%. According to the Bland-Altman method the mean differences between QCA and MSCT ranged from 0.55 to 1.07 mm with limits of agreement from 2.2 mm to 2.7 mm. Conclusion: When compared to QCA, the ability of 3D-VRT to quantitatively assess coronary artery diameters and coronary artery stenoses is insufficient for clinical purposes

  1. Classification of CT examinations for COPD visual severity analysis

    Science.gov (United States)

    Tan, Jun; Zheng, Bin; Wang, Xingwei; Pu, Jiantao; Gur, David; Sciurba, Frank C.; Leader, J. Ken

    2012-03-01

    In this study we present a computational method of CT examination classification into visual assessed emphysema severity. The visual severity categories ranged from 0 to 5 and were rated by an experienced radiologist. The six categories were none, trace, mild, moderate, severe and very severe. Lung segmentation was performed for every input image and all image features are extracted from the segmented lung only. We adopted a two-level feature representation method for the classification. Five gray level distribution statistics, six gray level co-occurrence matrix (GLCM), and eleven gray level run-length (GLRL) features were computed for each CT image depicted segment lung. Then we used wavelets decomposition to obtain the low- and high-frequency components of the input image, and again extract from the lung region six GLCM features and eleven GLRL features. Therefore our feature vector length is 56. The CT examinations were classified using the support vector machine (SVM) and k-nearest neighbors (KNN) and the traditional threshold (density mask) approach. The SVM classifier had the highest classification performance of all the methods with an overall sensitivity of 54.4% and a 69.6% sensitivity to discriminate "no" and "trace visually assessed emphysema. We believe this work may lead to an automated, objective method to categorically classify emphysema severity on CT exam.

  2. Study on the correlation between spiral CT features and expression of phosphatase and tensin homology deleted on chromosome ten, basic fibroblast growth factor in gastric carcinoma

    International Nuclear Information System (INIS)

    Gao Jianbo; Chen Xuejun; Yang Xuehua; Guo Hua; Zhou Zhigang; Yue Songwei; Li Hui

    2006-01-01

    Objective: To investigate the spiral CT features of gastric carcinoma in the invasion and metastasis and its correlation with the expression of phosphatase and tensin homology deleted on chromosome ten (PTEN) and basic fibroblast growth factor (bFGF). Methods: Spiral CT plain scan and triphasic enhanced scans were performed in 83 patients. The postoperative specimens were embedded with paraffin to obtain 5 μm thickness tissues and stained with HE and immunohistochemistry. Spiral CT findings were compared with the expression of phosphatase and tensin homology deleted on chromosome ten (PTEN) and basic fibroblast growth factor (bFGF). Results: (1) The accuracy of spiral CT in T and N staging of gastric carcinoma was 94.0% (78/83) and 89.2% (74/83), respectively. (2) The expression of PTEN was 47.0% (39/83) in gastric carcinoma. The expression of PTEN in T 3-4 (40.8%, 29/71) and N 1+2 (38.3%, 23/60) gastric carcinoma was significantly lower than that of T 2 (10/12) and N 0 (16/23)gastric carcinoma, respectively (χ 2 =7.439, P=0.006; χ 2 =6.511, P=0.011). (3) The expression of bFGF was 63.9% (53/83) in gastric carcinoma. The expression of bFGF in T 3-4 (70.4%, 50/71 )and N 1+2 (71.7%, 43/60) gastric carcinoma was significantly higher than that of T 2 (3/12) and N 0 (10/23) gastric carcinoma, respectively (χ 2 =7.314, P=0.007; χ 2 =5.724, P=0.017). (4) Both PTEN-positive expression and bFGF-positive expression were detected in 16 specimens. The expression of PTEN (41.0%, 16/39) was negatively correlated with that of bFGF (30.2%, 16/53) (r=-0.447, P=0.000). Conclusion: Spiral CT triphasic enhanced scans combined with biologic characteristics can improve diagnostic accuracy of gastric carcinoma in the invasion, metastasis and prognosis. (authors)

  3. Analytical examination of a spiral beam scanning method for uniform irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Mitsuhiro; Okumura, Susumu; Arakawa, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A new circular beam scanning method for uniform irradiation of high-energy, intense ion beams over a large area has been developed. A sweeping speed and a trajectory density in a radial direction are kept constant to obtain uniform fluence distribution. A radial position of a beam spot on a target and an angular frequency of the circular motion are expressed by an irrational function of time. The beam is swept continuously, and a beam trajectory becomes spiral. More than 90 % uniformity of the fluence distribution can been achieved over a large area. (author)

  4. Assessment of effective dose in paediatric CT examinations.

    Science.gov (United States)

    Dougeni, E; Chapple, C L; Willis, J; Panayiotakis, G

    2011-09-01

    Current concerns focus on the high doses encountered in computed tomography (CT) examinations as they are extending towards younger and more radiosensitive patients. Previous work produced conversion coefficients for effective dose (E) from dose-length product (DLP) for four anatomical body regions applicable to any patient size. This work aims to update the earlier work, incorporating the new ICRP 2007 tissue-weighting factors and testing the methodology on modern scanners. For each age and body region, E was determined relative to DLP. Measurements were carried out on a 64-slice scanner to test this methodology. The conversion coefficients show exponential decrease with patient size. Conversion factors for the pelvis region are lower than before (30-40 %), those for the chest increased (by up to 25 %) whereas those for the head and abdomen remained fairly similar. Application of the coefficients to modern scanners verified the results, so that this methodology can be applied for a wide range of paediatric CT examinations.

  5. Patient doses in chest CT examinations: Comparison of various CT scanners

    Directory of Open Access Journals (Sweden)

    Božović Predrag

    2013-01-01

    Full Text Available This paper presents results from study on patient exposure level in chest CT examinations. CT scanners used in this study were various Siemens and General Electric (GE models. Data on patient doses were collected for adult and pediatric patients. Doses measured for adult patients were lower then those determined as Diagnostic Reference Levels (DRL for Europe, while doses for pediatric patients were similar to those found in published data. As for the manufactures, slightly higher doses were measured on GE devices, both for adult and pediatric patients.

  6. Diagnosis of bronchiectasis with multislice spiral CT: accuracy of 3-mm-thick structured sections

    Energy Technology Data Exchange (ETDEWEB)

    Remy-Jardin, Martine; Amara, Assia; Campistron, Philippe; Mastora, Ioana; Remy, Jacques [Department of Radiology, Hospital Calmette, University Center of Lille, Boulevard Jules Leclerc, 59037, Lille Cedex (France); Delannoy, Valerie; Duhamel, Alain [Department of Medical Statistics, University of Lille, Place de Verdun, 59037, Lille Cedex (France)

    2003-05-01

    The aim of this study was to evaluate the accuracy of 3-mm-thick reconstructed sections in the diagnosis of bronchiectasis with multislice CT (MSCT). Forty consecutive patients suspected of bronchiectasis (23 females, 17 males; mean age 51 years) underwent MSCT of the entire thorax with a 4 x 1-mm collimation (120 kV, 0.5 s/rotation, 80 mAs/slice) and a pitch of 1.75. From each data set (mean z-axis coverage: 257 mm; mean duration: 21 s), two series of images were systematically generated: 1-mm (group 1) and 3-mm (group 2)-thick reconstructed scans. Both series of images were obtained at 10-mm intervals and reconstructed with a high-spatial-frequency algorithm. Two observers independently analyzed the presence of bronchiectasis and associated abnormalities in group-1 and group-2 lung images. No significant difference between group 1 and group 2 was found in: (a) the detection of bronchiectasis, identified in 24 patients (60%) in group 1 and in 23 patients (57.5%) in group 2 (p=0.08); (b) the evaluation of the extent of bronchiectasis, identifying focal bronchiectasis in 10 patients (25%) in group 1 and 7 patients (17.5%) in group 2 (p=0.39) and multifocal bronchiectasis in 16 patients (40%) in both groups; (c) the characterisation of bronchiectasis (cylindral bronchiectasis: group 1, n=24, 60%; group 2, n=21, 53%, p=0.08); varicose bronchiectasis: group 1, n=5, 12.5%; group 2, n=6, 15%, p=0.56; and cystic bronchiectasis: group 1, n=2, 5%; group 2, n=2, 5%. Apart from the identification of abnormal bronchial wall thickening (group 2, n=35, 87.5%, vs group 1, n=31, 77.5%, p<0.05), recognition of associated bronchopulmonary anomalies did not differ between the two groups. This study demonstrates a comparable accuracy of the 3- and 1-mm-thick reconstructed scans in the detection and characterization of bronchiectasis. These results suggest the potential usefulness of 3-mm-thick scans generated from 4 x 2.5-mm acquisitions in the screening of bronchiectasis, which would

  7. National Survey on Justification of CT-examinations in Sweden

    International Nuclear Information System (INIS)

    Almen, Anja; Leitz, Wolfram; Richter, Sven

    2009-02-01

    All examinations in diagnostic radiology shall be justified to avoid unnecessary irradiation of the patients. The objective of the study was to investigate the degree of justification for CT-examinations in Sweden. Referrals for all examinations performed during one day were retrospectively evaluated by a group of physicians. The study was designed and conducted by a project group lead by prof. Haakan Jorulf. The authors of this report have derived the results and conclusions on the basis of the data and are responsible for the content of this report. The principle result was that approximately 20 % of all examinations were not justified. The degree of justification varied strongly with organ examined, moderately with prescriber affiliation and weakly with geographical region. If unjustified examinations could be avoided a large dose reduction for the population would be achieved. This study shows that there is a need for improvements and the authority will continue to work with this issue

  8. National Survey on Justification of CT-examinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Almen, Anja; Leitz, Wolfram; Richter, Sven

    2009-02-15

    All examinations in diagnostic radiology shall be justified to avoid unnecessary irradiation of the patients. The objective of the study was to investigate the degree of justification for CT-examinations in Sweden. Referrals for all examinations performed during one day were retrospectively evaluated by a group of physicians. The study was designed and conducted by a project group lead by prof. Haakan Jorulf. The authors of this report have derived the results and conclusions on the basis of the data and are responsible for the content of this report. The principle result was that approximately 20 % of all examinations were not justified. The degree of justification varied strongly with organ examined, moderately with prescriber affiliation and weakly with geographical region. If unjustified examinations could be avoided a large dose reduction for the population would be achieved. This study shows that there is a need for improvements and the authority will continue to work with this issue

  9. CT angiography in case of occlusion of the basilar artery; Angiographische Diagnostik mittels Mehrzeilen-Spiral-CT beim Akutverschluss der Arteria basilaris

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, R.; Christopoulos, G.; Brunner, H.; Wedell, E. [Inst. fuer Diagnostische und Interventionelle Radiologie, Herz- und Gefaessklinik GmbH, Bad Neustadt an der Saale (Germany); Salveter, E.; Ziegler, V.; Griewing, B. [Neurologische Klinik GmbH, Bad Neustadt an der Saale (Germany)

    2004-07-01

    Objective: to evaluate the diagnostic efficiency of CT angiography in case of clinical signs of acute brainstem infarction for the therapeutic management of catheter-based local thrombolysis. Material and methods: 3 patients (2 males, 1 female) suffering from an acute onset of brainstem symptoms and being suspicious of an occluded basilar artery were included into this report. 1 patient underwent selective vertebral arteriography. 2 patients were initially examined with CT angiography using a 4-row scanner and 100ml intravenous contrast agent. Results: in one patient, an occlusion of the basilar artery was excluded with catheter-based angiography. Sub-sequently, the patient was treated with systemic thrombolysis using r-tPA because of a thalamus infarction seen in MRI. 2 patients who have been initially examined with CT angiography presented with complete occlusions of the basilar arteries. These patients underwent r-tPA thrombolysis by means of superselective micro-catheter approaches of the vertebrobasilar vessels. CT angiography was very useful for determinating the occlusion length of the basilar artery pre-therapeutically, and in 1 case for ruling out an occluded vertrebral artery for catheterization. All patients recovered well under thrombolytic therapy applied systemically or selectively. (orig.)

  10. Radiation doses in head CT examinations in Serbia: comparison among different CT units

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Bozovic, P.; Stankovic, J.; Hadnadjev, D.; Stojanovic, S.

    2012-01-01

    A rapid increase in number of Computed Tomography (CT) examinations has been observed world wide. As haed CT is the most frequent CT examination, the purpose of this study was to collect and analyse patient doses in children and adults in different CT units for this procedure. The study included 8 CT units from three manufacturers (Siemens, Toshiba and General Electric). Data for adults and pediatric patients were collected in terms of CTDIvol and DLP values. The doses were estimated as a mean value of 10 patients on each CT unit. For pediatrics, doses were collected for four age groups (0-1year, >1-5years, >5-10years and >10-15years). Comparing different manufacturers and the same number of detector rows it was observed that, in case of 16 slices units, doses were very similar on Siemens and General Electric scanner. CTDIvol and DLP on Siemens scanner were 60 mGy and 1066 mGy·cm, respectively, while on General Electric those values were 66 mGy and 1050 mGy·cm. However, this trend was not observed in case of 64 slices units. CTDIvol and DLP values collected on Toshiba were much higher (177 mGy and 2109 mGy·cm) than in case of Siemens scanner (59 mGy and 1060 mGy·cm). Doses on 16 and 64 slices Siemens scanners were very similar, while on 4 slices were higher. Except in two units, doses were were in line with DRLs. In case of pediatrics, doses increase with patient age and again Siemens scanner showed the lowest values while the highest were observed on Toshiba. (authors)

  11. Assessment of Patient Dose from CT Examinations in Khorasan, Iran

    Directory of Open Access Journals (Sweden)

    Mohammad Taghi Bahreyni Toossi

    2013-03-01

    Full Text Available Introduction Computed Tomography scans are a very important tool for diagnosis and assessment of response to treatment in the practice of medicine. Ionizing radiation in medical imaging is undoubtedly one of the most powerful diagnostic tools in medicine. Yet, as with all medical interventions, there are potential risks in addition to the clear potential benefits. Materials and Methods Two reference dose quantities have been defined in order to promote the use of good technique in CT. These are weighted CT dose index (CTDIw in (mGy for a single slice in serial scanning or per rotation in helical scanning, and dose–length product (DLP per complete examination (mGy.cm, All measurements were performed using a pencil shaped ionization chamber introduced into polymethyl methacrylate cylindrical brain and body phantoms. This survey was performed on 7 CT scanners in Khorasan Province-Iran. Results DLP for brain, chest, abdomen and pelvic examinations had a range of 255 - 1026, 76-1277, 48-737, 69-854 mGy.cm, respectively. Conclusion The results obtained in this study show that the DLP values obtained in this province are lower than European Commission reference dose levels (EC RDL, in other words performance of all the scanners were satisfactory.

  12. Automated extraction of radiation dose information for CT examinations.

    Science.gov (United States)

    Cook, Tessa S; Zimmerman, Stefan; Maidment, Andrew D A; Kim, Woojin; Boonn, William W

    2010-11-01

    Exposure to radiation as a result of medical imaging is currently in the spotlight, receiving attention from Congress as well as the lay press. Although scanner manufacturers are moving toward including effective dose information in the Digital Imaging and Communications in Medicine headers of imaging studies, there is a vast repository of retrospective CT data at every imaging center that stores dose information in an image-based dose sheet. As such, it is difficult for imaging centers to participate in the ACR's Dose Index Registry. The authors have designed an automated extraction system to query their PACS archive and parse CT examinations to extract the dose information stored in each dose sheet. First, an open-source optical character recognition program processes each dose sheet and converts the information to American Standard Code for Information Interchange (ASCII) text. Each text file is parsed, and radiation dose information is extracted and stored in a database which can be queried using an existing pathology and radiology enterprise search tool. Using this automated extraction pipeline, it is possible to perform dose analysis on the >800,000 CT examinations in the PACS archive and generate dose reports for all of these patients. It is also possible to more effectively educate technologists, radiologists, and referring physicians about exposure to radiation from CT by generating report cards for interpreted and performed studies. The automated extraction pipeline enables compliance with the ACR's reporting guidelines and greater awareness of radiation dose to patients, thus resulting in improved patient care and management. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Clinically relevant incidental cardiovascular findings in CT examinations; Klinisch relevante kardiovaskulaere Zufallsbefunde bei CT-Untersuchungen

    Energy Technology Data Exchange (ETDEWEB)

    Voigt, P.; Fahnert, J.; Kahn, T.; Surov, A. [Universitaetsklinikum Leipzig, Klinik fuer Diagnostische und Interventionelle Radiologie, Leipzig (Germany); Schramm, D.; Bach, A.G. [Universitaetsklinikum Halle (Saale), Klinik fuer Radiologie, Halle (Germany)

    2017-04-15

    Incidental cardiovascular findings are a frequent phenomenon in computed tomography (CT) examinations. As the result of a dedicated PubMed search this article gives a systemic overview of the current literature on the most important incidental cardiovascular findings, their prevalence and clinical relevance. The majority of incidental cardiovascular findings are of only low clinical relevance; however, highly relevant incidental findings, such as aortic aneurysms, thromboses and thromboembolic events can also occasionally be found, especially in oncology patients. The scans from every CT examination should also be investigated for incidental findings as they can be of decisive importance for the further clinical management of patients, depending on their clinical relevance. (orig.) [German] Inzidentelle kardiovaskulaere Befunde sind ein haeufiges Phaenomen bei CT-Untersuchungen. Mit dieser Arbeit soll nach gezielter PubMed-Recherche ein systematischer Literaturueberblick ueber die wichtigsten kardiovaskulaeren Zufallsbefunde sowie deren Haeufigkeit und klinische Relevanz gegeben werden. Die Mehrzahl der inzidentellen kardiovaskulaeren Befunde sind klinisch nur von untergeordneter Bedeutung, allerdings werden immer wieder auch hochgradig relevante Zufallsbefunde wie beispielsweise Aortenaneurysmata oder - gerade bei onkologischen Patienten - Thrombosen und thrombembolische Ereignisse detektiert. Jede CT-Untersuchung sollte gezielt nach inzidentellen Befunden durchsucht werden, da diese je nach klinischer Relevanz von entscheidender Bedeutung fuer das weitere klinische Management des Patienten sein koennen. (orig.)

  14. Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kai; Ma, Rui; Wang, Li Jun [Dept. of Radiology, Baotou Central Hospital, Baotou (China); Li, Li Gang; Chen, Jiu Hong [CT BM Clinic Marketing, Siemens Healthcare, Beijing (China)

    2012-11-15

    To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 {+-} 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed. There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 {+-} 0.306 [group A] vs. 1.084 {+-} 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 {+-} 0.16 mSv in group A and 7.1 {+-} 1.05 mSv in group B (p = 0.001). In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

  15. Visualization of normal and abnormal inner ear with volume rendering technique using multislice spiral CT

    International Nuclear Information System (INIS)

    Ma Hui; Han Ping; Liang Bo; Lei Ziqiao; Liu Fang; Tian Zhiliang

    2006-01-01

    Objective: To evaluate the ability of the volume rendering technique to display the normal and abnormal inner ear structures. Methods: Forty normal earand 61 abnormal inner ears (40 congenital inner ear malformations, 7 labyrinthitis ossificans, and 14 inner ear erosion caused by cholesteatomas) were examined with a MSCT scanner. Axial imaging were performed using the following parameters: 120 kV, 100 mAs, 0.75 mm slice thickness, a pitch factor of 1. The axial images of interested ears were reconstructed with 0.1 mm reconstruction increment and a FOV of 50 mm. The 3D reconstructions were done with volume rendering technique on the workstation. Results: In the subjects without ear disorders a high quality 3D visualization of the inner ear could be achieved. In the patients with inner ear' disorders all inner ear malformations could be clearly displayed on 3D images as follows: (1) Michel deformity (one ear): There was complete absence of all cochlear and vestibular structures. (2) common cavity deformity (3 ears): The cochlea and vestibule were represented by a cystic cavity and couldn't be differentiated from each other. (3)incomplete partition type I (3 ears): The cochlea lacked the entire modiolus and cribriform area, resulting in a cystic appearance. (4) incomplete partition type II (Mondini deformity) (5 ears): The cochlea consisted of 1.5 turns, in which the middle and apical turns coalesced to form a cystic apex. (5) vestibular and semicircular canal malformations (14 ears): Cochlea was normal, vestibule dilated, semicircular canals were absent, hypoplastic or enlarged. (6) dilated vestibular aqueduct (14 ears): The vestibular aqueduct was bell-mouthed. In 7 patients with labyrinthifis ossificans, 3D images failed to clearly show the completeinner ears in 4 ears because of too high ossifications in the membranous labyrinth. In the other 3 ears volume rendering could display the thin cochlea basal turn and the intermittent semicircular canals. In the patients

  16. Usefulness of air as oraI contrast material at CT examination in patient with post-operative gastric cancer

    International Nuclear Information System (INIS)

    Chung, Jae Joon; Kim, Myeong Jin; Kim, Joo Hee; Kim, Ki Whang

    2004-01-01

    To evaluate the usefulness of multidetector-row CT (MDCT) with gastric luminal distention using effervescent granules in patients with previous subtotal gastrectomy for the evaluation of the stomach, anastomotic site and jejunum, and to compare its findings with those of spiral CT using oral contrast media in the same patients. Thirty-one patients (M:F = 25:6, mean age; 58 years) with previous subtotal gastrectomy, who underwent both spiral CT using oral contrast media and MDCT using effervescent granules, were studied. The distensibility of the gastric lumen, anastomotic site and jejunal lumen was graded as either poor, fair or good. The thickening or mass of the gastric and small bowel wall was also evaluated. The distensibility of the gastric lumen, anastomotic site and jejunal lumen were better demonstrated by MDCT using effervescent granules than by spiral CT using an oral contrast agent (p<0.005). The distensibility of the stomach and jejunum was similar in 14 cases (45.2%) on spiral CT and 16 cases (51.6%) on MDCT. The anastomotic site was better demonstrated when effervescent granules were used than when oral contrast media was used in 21 cases (67.7%). No cases of poor distention of the stomach or anastomotic site were detected when using effervescent granules. Follow-up MDCT using effervescent granules showed better distensibility of the gastric lumen, anastomotic site and jejunal lumen than spiral CT using oral contrast media in all of the patients having undergone subtotal gastrectomy

  17. Angiogenesis in hepatocellular carcinoma: correlation of single-level dynamic spiral CT scans in arterial phase and expression of α-smooth muscle actin

    International Nuclear Information System (INIS)

    Liu Yan; Min Pengqiu; Chen Weixia; Zhang Lin

    2005-01-01

    Objective: To investigate the correlation between the single-level dynamic spiral CT scans (SDCT) of hepatocellular carcinoma (HCC) in arterial phase (AP) and the immunohistochemistry expression of α-smooth muscle actin (ASMA). Methods: 33 cases of suspected HCC undergoing spiral CT plain scan of the whole liver, the single-level dynamic scan of the target level of lesion in AP and finally the whole liver scan in portal-venous phase before operations and proved after were included into the study. After the SDCT, a time-density curve (T-DC) was drawn according to the density change of the region of interest (ROI) of the tumor parenchyma with some parameters calculated, and signs of enhancement evaluated. Slices of post-operation specimen underwent hemotoxylin-eosin (HE) and ASMA immunohistochemistry staining. Then the slices were evaluated with emphases on the ASMA-positive neovasculatures in the parenchyma and mesenchyma of carcinomas, and the average count in a low microscopic field (x 100) was recorded (5 low microscopic field were observed and then an average was calculated.). Finally the immunohistochemistry and histologic results were correlated with image findings. Results: According to the PV of the tumor parenchyma, T-DC was divided into type I, II and III in which the criteria were PV>80, 40 HU< PV< 80 HU and PV<40 HU respectively. In the 33 cases, type I, II and III of T-DC were 3, 17 and 13 cases with PV of 103.30, 57.65 and 33.55 HU respectively. In ASMA immunohistochemistry study, ASMA-positive neovasculatures were devided into type A with a thick wall and B with a thin wall. The mean count of neovasculatures of tumor parenchyma in type I, II and III of T-DC were 10, 4.59 and 1 respectively. Statistically, different types of T-DC were significantly correlated with the count of neovasculatures in the parenchyma of carcinomas (r=-0.567, P<0.01). Homogeneous and inhomogeneous enhancement of carcinomas during SDCT in AP were correlated with the

  18. Sprial CT cholangiography. A new technique in the examination of the biliary tract

    International Nuclear Information System (INIS)

    Cabada, T.; Martinez-Berganza, M.T.; Cozcolluela, R.; Sarria, L.; Soto, J.A.

    1997-01-01

    A number of techniques, including ultrasonography, intravenous cholangiography, endoscopic retrograde cholangiopancreatorgraphy, intraoperative cholangiography and conventional computerized tomography, have been employed in the study of the biliary tract. CT cholangiography involves a spiral technique used to study the hepatobiliary region after administration of a cholangiographic contrast material, which permits subsequent multiplanar and three-dimensional reconstructions. Spiral CT cholangiography is a recently introduced, noninvasive technique that provides a good image of the complex biliary anatomy, and it is a reliable method for the detection of both choledocholithiasis and intrahepatic calculi. This technique may play an important role in the preoperative study of patients scheduled to underg laparoscopic cholecystectomy and in the assessment of the complications that develop after cholecystectomy. (Author) 42 refs

  19. Effective dose from cone beam CT examinations in dentistry.

    Science.gov (United States)

    Roberts, J A; Drage, N A; Davies, J; Thomas, D W

    2009-01-01

    Cone beam CT (CBCT) is becoming an increasingly utilized imaging modality for dental examinations in the UK. Previous studies have presented little information on patient dose for the range of fields of view (FOVs) that can be utilized. The purpose of the study was therefore to calculate the effective dose delivered to the patient during a selection of CBCT examinations performed in dentistry. In particular, the i-CAT CBCT scanner was investigated for several imaging protocols commonly used in clinical practice. A Rando phantom containing thermoluminescent dosemeters was scanned. Using both the 1990 and recently approved 2007 International Commission on Radiological Protection recommended tissue weighting factors, effective doses were calculated. The doses (E(1990), E(2007)) were: full FOV head (92.8 microSv, 206.2 microSv); 13 cm scan of the jaws (39.5 microSv, 133.9 microSv); 6 cm high-resolution mandible (47.2 microSv, 188.5 microSv); 6 cm high-resolution maxilla (18.5 microSv, 93.3 microSv); 6 cm standard mandible (23.9 microSv, 96.2 microSv); and 6 cm standard maxilla (9.7 microSv, 58.9 microSv). The doses from CBCT are low compared with conventional CT but significantly higher than conventional dental radiography techniques.

  20. Blood flow patterns of solitary pulmonary nodules with enhancement: clinical value of multi-slice spiral CT

    International Nuclear Information System (INIS)

    Li Shenjiang; Xiao Xiangsheng; Liu Shiyuan; Liu Huimin; Li Yuli; Li Huimin; Li Chengzhou; Zhang Chenshi; Tao Zhiwei; Yang Chunshan; Jiang Qingjun; Ouyang Lin; Yu Hong

    2004-01-01

    Objective: To evaluate the efficacy of dynamic multi-slice spiral computed tomography (MSCT) for providing quantitative information about blood flow patterns of solitary pulmonary nodules (SPNs) and the correlation of vascular endothelial growth factor (VEGF)-positive tumor angiogenesis and the quantifiable parameters of blood flow pattern in solitary bronchogenic adenocarcinoma. Methods Seventy-eight patients with SPNs (with strong enhancement) (diameter ≤4 cm; 68 malignant; 10 active inflammatory) underwent multi-location dynamic contrast enhanced (nonionic contrast material was administrated via the antecubital vein at a rate of 4 ml/s by using an autoinjector) serial CT. Precontrast and postcontrast attenuation on every scan was recorded. Perfusion, peak height, and ratio of peak height of the SPN to that of the aorta were calculated. Perfusion was calculated from the maximum gradient of the time-attenuation curve and the peak height of the aorta. The quantifiable parameters (perfusion, peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta and mean transit time) of blood flow pattern in 30 VEGF-positive solitary bronchogenic adenocarcinoma were compared with microvessel densities (MVD) and VEGF expression by immunohistochemistry. Results: No statistically significant difference in the peak height was found between malignant (35.79 ± 10.76) HU and active inflammatory (39.76 ± 4.59) HU nodules (t=1.148, P=0.255). SPN-to-aorta ratio (14.27 ± 4.37)% and perfusion value (3.02 ± 0.96)ml -1 ·min -1 ·kg -1 in malignant SPNs were significantly lower than those of active inflammatory nodules(18.51 ± 2.71)%, (6.34 ± 4.39)ml -1 ·min -1 ·kg -1 (t=2.978, P=0.004, t=5.590, P -1 ·min -1 ·kg -1 , mean transit time (14.86 ± 5.84) s, and MVD (70.15 ± 20.03). Each of peak height, ratio of peak height of the bronchogenic adenocarcinoma to that of the aorta, and perfusion correlated positively with MVD (r=0.781, P<0.0001; r=0

  1. Value of 64-slice spiral CT angiography for follow-up of young children with coronary artery aneurysms due to Kawasaki disease

    International Nuclear Information System (INIS)

    Peng Yun; Zeng Jinjin; Liu Shichen; Du Zhongdong; Sun Guoqiang; Guo Huiling

    2008-01-01

    Objective: To assess the value and feasibility of 64-slice spiral CT in diagnosis of coronary artery aneurysm in the follow-up of young children with previous Kawasaki disease. Methods Twelve boys (mean age 5.1 years) for follow-up (ranged 1.1 to 5.1 years) with known Kawasaki disease and coronary artery aneurysms underwent coronary CT angiography using 64-slice spiral CT. The number, location, shape and size of each coronary artery, aneurysm were recorded and compared with those of echocardiography performed simutaneously. Results: A total of 30 coronary artery aneurysms were identified with mean diameter of (7.5±3.8) mm, and mean maximum length of (12.4±9.1)mm. 10 aneurysms were small in size,7 aneurysms were medium in size and 13 were giant aneurysms. Fourteen aneurysms were saccular, and the remaining 16 were fusiform. Among the aneurysms in left coronary artery, 7 of them were located in the main branch, 9 were located in the proximal segment of the anterior descending branch, 4 were located at the middle segment of the anterior descending branch, and 2 were located in the circumflex branch. Among the aneurysms in right coronary artery, 6 of them were located in the proximal segment, 9 were located in the middle segment, and 4 were located at the distal segment. Nine of the aneurysms involved 2 segments of the coronary arteries, and one involved 3 segments. Six stenotic segments were found. Calcification was found in 5 aneurysms and 3 of them had thrombosis. Echocardiography failed to detect 8 aneurysms of small size and located in the middle or distal segments of the coronary arterys. Conclusion: The 64-slice CT angiography proved valuable for monitoring young children with Kawasaki disease. (authors)

  2. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: image reconstruction and assessment of image quality.

    Science.gov (United States)

    Flohr, Thomas G; Leng, Shuai; Yu, Lifeng; Aiimendinger, Thomas; Bruder, Herbert; Petersilka, Martin; Eusemann, Christian D; Stierstorfer, Karl; Schmidt, Bernhard; McCollough, Cynthia H

    2009-12-01

    To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. No significant differences in quantitative measures of image quality were found between single-source scans at pitch = 1.0 and dual-source scans at pitch = 3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6 pitch 3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch = 3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom

  3. An evaluation of the feasibility of assessment of volume perfusion for the whole lung by 128-slice spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Haitao [Imaging Center of Taian Central Hospital, Taian, Shandong (China); Gao, Fei; Li, Ning; Liu, Cheng [Shandong Univ., Shandong Medical Imaging Research Inst., CT Room, Shandong (China)], e-mail: liucheng491025@sina.com

    2013-10-15

    Background: Lung perfusion based on dynamic scanning cannot provide a quantitative assessment of the whole lung because of the limited coverage of the current computed tomography (CT) detector designs. Purpose: To evaluate the feasibility of dynamic volume perfusion CT (VPCT) of the whole lung using a 128-slice CT for the quantitative assessment and visualization of pulmonary perfusion. Material and Methods: Imaging was performed in a control group of 17 subjects who had no signs of disturbance of pulmonary function or diffuse lung disease, and 15 patients (five patients with acute pulmonary embolism and 10 with emphysema) who constituted the abnormal lung group. Dynamic VPCT was performed in all subjects, and pulmonary blood flow (PBF), pulmonary blood volume (PBV), and mean transit time (MTT) were calculated from dynamic contrast images with a coverage of 20.7 cm. Regional and volumetric PBF, PBV, and MTT were statistically evaluated and comparisons were made between the normal and abnormal lung groups. Results: Regional PBF (94.2{+-}36.5, 161.8 {+-}29.6, 185.7 {+-}38.1 and 125.5 {+-}46.1, 161.9 {+-}31.4, 169.3 {+-}51.7), PBV (6.7 {+-}2.8, 10.9 {+-}3.0, 12.9 {+-}4.5 and 9.9 {+-}4.6, 10.3 {+-}2.9, 11.9 {+-}4.5), and MTT (5.8 {+-}2.4, 4.5 {+-}1.3, 4.7 {+-}2.1 and 5.6 {+-}2.3, 4.3 {+-}1.5, 4.9 {+-}1.5) demonstrated significant differences in the gravitational and isogravitational directions in the normal lung group (P < 0.05). The PBF (154.2 {+-}30.6 vs. 94.9 {+-}15.9) and PBV (11.1 {+-}4.0 vs. 6.6 {+-}1.7) by dynamic VPCT showed significant differences between normal and abnormal lungs (P < 0.05), notwithstanding the four large lungs that had coverage > 20.7 cm. Conclusion: Dynamic VPCT of the whole lung is feasible for the quantitative assessment of pulmonary perfusion by 128-slice CT, and may in future permit the evaluation of both morphological and functional features of the whole lung in a single examination.

  4. A new low-dose CT examination compared with standard-dose CT in the diagnosis of acute sinusitis

    Energy Technology Data Exchange (ETDEWEB)

    Hagtvedt, T.; Aaloekken, T.M.; Noetthellen, J.; Kolbenstvedt, A. [Department of Radiology, Rikshospitalet, 0027 Oslo (Norway)

    2003-05-01

    A low-dose CT of the paranasal sinuses was designed with few, thin sections, non-uniform intersection gaps, low milliampere settings and avoidance of direct radiation to the eye lens. The low-dose CT was prospectively compared with standard-dose CT in patients with suspicion of acute sinusitis. Forty-seven patients were examined with low-dose CT immediately after standard-dose CT. The effective dose and the lens dose were calculated and compared. Using standard-dose CT as a gold standard the sensitivity and specificity of low-dose CT was calculated for each sinus group. The effective dose and the lens dose of the low-dose CT were reduced to, respectively, 3 and 2% of the standard-dose CT. The diagnostic yield of the low-dose CT with regard to acute sinusitis was good with a high specificity ({>=}96%) for all sinus groups. The sensitivity was also high ({>=}95%) except for the frontal sinus where the sensitivity was 83%. Low-dose CT offers considerable dose reduction and should be the standard for imaging patients with suspected acute inflammatory paranasal disease. (orig.)

  5. Low contrast media volume in pre-TAVI CT examinations.

    Science.gov (United States)

    Kok, Madeleine; Turek, Jakub; Mihl, Casper; Reinartz, Sebastian D; Gohmann, Robin F; Nijssen, Estelle C; Kats, Suzanne; van Ommen, Vincent G; Kietselaer, Bas L J H; Wildberger, Joachim E; Das, Marco

    2016-08-01

    To evaluate image quality using reduced contrast media (CM) volume in pre-TAVI assessment. Forty-seven consecutive patients referred for pre-TAVI examination were evaluated. Patients were divided into two groups: group 1 BMI  28 kg/m(2) (n = 18). Patients received a combined scan protocol: retrospective ECG-gated helical CTA of the aortic root (80kVp) followed by a high-pitch spiral CTA (group 1: 70 kV; group 2: 80 kVp) from aortic arch to femoral arteries. All patients received one bolus of CM (300 mgI/ml): group 1: volume = 40 ml; flow rate = 3 ml/s, group 2: volume = 53 ml; flow rate = 4 ml/s. Attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the levels of the aortic root (helical) and peripheral arteries (high-pitch). Diagnostic image quality was considered sufficient at attenuation values > 250HU and CNR > 10. Diagnostic image quality for TAVI measurements was obtained in 46 patients. Mean attenuation values and CNR (HU ± SD) at the aortic root (helical) were: group 1: 381 ± 65HU and 13 ± 8; group 2: 442 ± 68HU and 10 ± 5. At the peripheral arteries (high-pitch), mean values were: group 1: 430 ± 117HU and 11 ± 6; group 2: 389 ± 102HU and 13 ± 6. CM volume can be substantially reduced using low kVp protocols, while maintaining sufficient image quality for the evaluation of aortic root and peripheral access sites. • Image quality could be maintained using low kVp scan protocols. • Low kVp protocols reduce contrast media volume by 34-67 %. • Less contrast media volume lowers the risk of contrast-induced nephropathy.

  6. Clinical relevance of multislice CT of the spine after osteosynthesis; Postoperative Kontrolle von osteosynthetischen Versorgungen der Wirbelsaeule mit der Mehrzeilen-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzen, M.; Wedegaertner; Weber, C.; Adam, G.; Lorenzen, J. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Petersen, J.P. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Orthopaedie

    2005-11-15

    Purpose: To examine the clinical relevance of multislice CT (MSCT) scans in postoperative checks of the spine after osteosynthesis. Material and Methods: The results of x-rays (apical lateral) in 30 patients having spinal surgery involving Xosteosynthesis (5 x metastasis, 20 x fractures, 3 x spondylolisthesis, 2 x scoliosis) were correlated to those of MSCT (140 kV, 200 mAs, collimation 4 x 1 mm, pitch 0.75; VolumeZoom, Siemens, Erlangen, Germany) with multiplanar reconstruction. Two radiologists independently checked the conventional X-ray and multislice CT scans for anatomical positioning, damage of osteosynthetic material, and intraspinal dislocation of bone fragments. Results: By correlating conventional spinal X-rays with MSCT, additional diagnostic information was gained. In 9 of 30 patients MSCT revealed the extraosseal location of a screw tip (X-ray, 5/30), in 8/30 patients a narrowing of the spinal canal by osteosynthetic material was detected in MSCT (X-ray, 4/30), in 2/30 patients osteal fragments were detected in the vertebral canal by MSCT (X-ray, 0/30). In MSCT and in conventional X-ray a fracture of the osteosynthesis was correctly diagnosed in 3 patients. One patient underwent corrective surgery for dislocated osteosynthetic material, which was solely diagnosed with MSCT. Conclusion: Due to the high degree of additional diagnostic information MSCT seems to be the method of choice for postoperative spinal surgery involving osteosynthesis. (orig.)

  7. CT examination of the temporal bones for cochlear implantation; Badanie CT kosci skroniowych u osob przygotowanych do operacji wszczepu slimakowego

    Energy Technology Data Exchange (ETDEWEB)

    Szyfter, W.; Szymiec, E.; Pruszewicz, A.; Szmeja, Z.; Paprzycki, W.; Sekula, A.; Przybylska, J. [Klinika Otolaryngologii, Akademia Medyczna, Poznan (Poland)

    1995-12-31

    CT examinations of temporal bones were performed in 31 deaf patients from qualify diagnostic stage prepared for cochlear implants. Essential for surgical treatment anatomic details were estimated, especially canalis spiralis cochleae was paid to attention. In our group, 8 patients had some CT changes (abnormal findings) which corresponded to different stages of obliteration the cochlea. The majority of patients lost the hearing because of meningitis. In 6 implanted patients CT scan was compared with surgical findings. During the operation 1 patient with patent cochlea on CT scan had partially ossified basal turn. (author) 16 refs, 4 figs, 2 tabs

  8. The spiral

    DEFF Research Database (Denmark)

    Bibace, Roger; Kharlamov, Nikita

    2013-01-01

    ’s work with Bernard Kaplan on symbol formation is a primer on this idea. This paper examines the idea of spirality and develops the notion of dynamic coexistence that can clarify the issue of directionality of development; that is, what is the general trajectory or ground plan that development assumes....... Directionality is discussed in terms of the organism-in-environment unfolding over time as the unit of developmental analysis. Thinking on this issue has proceeded from the nature–nurture debates, to recognition of the interaction of external and internal processes, to transactions between the organism...

  9. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.

    Science.gov (United States)

    Jarry, G; DeMarco, J J; Beifuss, U; Cagnon, C H; McNitt-Gray, M F

    2003-08-21

    The purpose of this work is to develop and test a method to estimate the relative and absolute absorbed radiation dose from axial and spiral CT scans using a Monte Carlo approach. Initial testing was done in phantoms and preliminary results were obtained from a standard mathematical anthropomorphic model (MIRD V) and voxelized patient data. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) to simulate the CT x-ray source and movement, and then to calculate absorbed radiation dose in desired objects. The movement of the source in either axial or spiral modes was modelled explicitly while the CT system components were modelled using published information about x-ray spectra as well as information provided by the manufacturer. Simulations were performed for single axial scans using the head and body computed tomography dose index (CTDI) polymethylmethacrylate phantoms at both central and peripheral positions for all available beam energies and slice thicknesses. For comparison, corresponding physical measurements of CTDI in phantom were made with an ion chamber. To obtain absolute dose values, simulations and measurements were performed in air at the scanner isocentre for each beam energy. To extend the verification, the CT scanner model was applied to the MIRD V model and compared with published results using similar technical factors. After verification of the model, the generalized source was simulated and applied to voxelized models of patient anatomy. The simulated and measured absolute dose data in phantom agreed to within 2% for the head phantom and within 4% for the body phantom at 120 and 140 kVp; this extends to 8% for the head and 9% for the body phantom across all available beam energies and positions. For the head phantom, the simulated and measured absolute dose data agree to within 2% across all slice thicknesses at 120 kVp. Our results in the MIRD phantom agree within 11% of all the different organ dose values

  10. Logarithmic Spiral

    Indian Academy of Sciences (India)

    anti-clockwise direction and we get a right-handed spiral. (Figure 2). We know that the derivative of eX is also eX. Various properties of logarithmic spiral depend on this property of eX. Properties of Logarithmic Spiral. 1. The most important property of a logarithmic spiral is that r (i.e. the distance from the origin) increases.

  11. Diagnostic efficacy of gadoxetic acid (Primovist)-enhanced MRI and spiral CT for a therapeutic strategy: comparison with intraoperative and histopathologic findings in focal liver lesions

    International Nuclear Information System (INIS)

    Hammerstingl, Renate; Vogl, Thomas J.; Huppertz, Alexander; Breuer, Josy; Balzer, Thomas; Blakeborough, Anthony; Carter, Rick; Castells Fuste, Lluis; Heinz-Peer, Gertraud; Judmaier, Werner; Laniado, Michael; Manfredi, Riccardo M.; Mathieu, Didier G.; Mueller, Dieter; Mortele, Koenraad; Reimer, Peter; Reiser, Maximilian F.; Robinson, Philip J.; Shamsi, Kohkan; Strotzer, Michael; Taupitz, Matthias; Tombach, Bernd; Valeri, Gianluca; Beers, Bernhard E. van

    2008-01-01

    A multicenter study has been employed to evaluate the diagnostic efficacy of magnetic resonance imaging (MRI) using the new liver-specific contrast agent gadoxetic acid (Gd-EOB-DTPA, Primovist), as opposed to contrast-enhanced biphasic spiral computed tomography (CT), in the diagnosis of focal liver lesions, compared with a standard of reference (SOR). One hundred and sixty-nine patients with hepatic lesions eligible for surgery underwent Gd-EOB-DTPA-enhanced MRI as well as CT within 6 weeks. Pathologic evaluation of the liver specimen combined with intraoperative ultrasound established the SOR. Data sets were evaluated on-site (14 investigators) and off-site (three independent blinded readers). Gd-EOB-DTPA was well tolerated. Three hundred and two lesions were detected in 131 patients valid for analysis by SOR. The frequency of correctly detected lesions was significantly higher on Gd-EOB-DTPA-enhanced MRI compared with CT in the clinical evaluation [10.44%; 95% confidence interval (CI): 4.88, 16.0]. In the blinded reading there was a trend towards Gd-EOB-DTPA-enhanced MRI, not reaching statistical significance (2.14%; 95% CI: -4.32, 8.6). However, the highest rate of correctly detected lesions with a diameter below 1 cm was achieved by Gd-EOB-DTPA-enhanced MRI. Differential diagnosis was superior for Gd-EOB-DTPA-enhanced MRI (82.1%) versus CT (71.0%). A change in surgical therapy was documented in 19 of 131 patients (14.5%) post Gd-EOB-DTPA-enhanced MRI. Gd-EOB-DTPA-enhanced MRI was superior in the diagnosis and therapeutic management of focal liver lesions compared with CT. (orig.)

  12. Diagnostic efficacy of gadoxetic acid (Primovist)-enhanced MRI and spiral CT for a therapeutic strategy: comparison with intraoperative and histopathologic findings in focal liver lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstingl, Renate; Vogl, Thomas J. [Johann Wolfgang Goethe-Univ., Inst. of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Huppertz, Alexander [Imaging Science Inst., Charite - Siemens, Berlin (Germany); Breuer, Josy; Balzer, Thomas [Gobal Clinical Development Diagnostics, Bayer Schering Pharma AG, Berlin (Germany); Blakeborough, Anthony [Royal Hallamshire Hospital, Dept. of Radiology, Sheffield (United Kingdom); Carter, Rick [Bayer Health Care Ltd., Burgess Hill, West Sussex (United Kingdom); Castells Fuste, Lluis [Hospital Vall d' Hebron, Liver Unit, Dept. of Internal Medicine, Barcelona (Spain); Heinz-Peer, Gertraud [Universitaetsklinik fuer Radiodiagnostik, Allg. Krankenhaus der Stadt Wien, Wien (Germany); Judmaier, Werner [Univ. Hospital Innsbruck, Dept. of Magnetic Resonance Imaging and Spectroscopy, Innsbruck (Austria); Laniado, Michael [Universitaetsklinikum Carl Gustav Carus, Technische Univ. Dresden, Inst. for Diagnostic Radiology, Dresden (Germany); Manfredi, Riccardo M. [Univ. of Verona, Dept. of Radiology, Verona (Italy); Mathieu, Didier G. [Centre d' Imagerie, Aix en Provence (France); Mueller, Dieter [Georg-August Univ., Dept. of Radiology, Goettingen (Germany); Mortele, Koenraad [Brigham and Women' s Hospital, Dept. of Radiology (L1), Boston, MA (United States); Reimer, Peter [Klinikum Karlsruhe, Dept. of Radiology, Karlsruhe (Germany); Reiser, Maximilian F. [Ludwig-Maximilians-Univ. Munich - Klinikum Grosshadern, Inst. of Clinical Radiology, Munich (Germany); Robinson, Philip J. [St James' s Univ. Hospital, Dept. of Clinical Radiology, Leeds (United Kingdom); Shamsi, Kohkan [Berlex Labs. Inc., Montville, NJ (United States); Strotzer, Michael [Univ. Hospital, Dept. of Diagnostic Radiology, Regensburg (Germany); Taupitz, Matthias [Universitaetsklinikum Charite, Med. Fakultaet der Humboldt-Univ., Dept. of Radiology, Berlin (Germany); Tombach, Bernd; Valeri, Gianluca; Beers, Bernhard E. van [and others

    2008-03-15

    A multicenter study has been employed to evaluate the diagnostic efficacy of magnetic resonance imaging (MRI) using the new liver-specific contrast agent gadoxetic acid (Gd-EOB-DTPA, Primovist), as opposed to contrast-enhanced biphasic spiral computed tomography (CT), in the diagnosis of focal liver lesions, compared with a standard of reference (SOR). One hundred and sixty-nine patients with hepatic lesions eligible for surgery underwent Gd-EOB-DTPA-enhanced MRI as well as CT within 6 weeks. Pathologic evaluation of the liver specimen combined with intraoperative ultrasound established the SOR. Data sets were evaluated on-site (14 investigators) and off-site (three independent blinded readers). Gd-EOB-DTPA was well tolerated. Three hundred and two lesions were detected in 131 patients valid for analysis by SOR. The frequency of correctly detected lesions was significantly higher on Gd-EOB-DTPA-enhanced MRI compared with CT in the clinical evaluation [10.44%; 95% confidence interval (CI): 4.88, 16.0]. In the blinded reading there was a trend towards Gd-EOB-DTPA-enhanced MRI, not reaching statistical significance (2.14%; 95% CI: -4.32, 8.6). However, the highest rate of correctly detected lesions with a diameter below 1 cm was achieved by Gd-EOB-DTPA-enhanced MRI. Differential diagnosis was superior for Gd-EOB-DTPA-enhanced MRI (82.1%) versus CT (71.0%). A change in surgical therapy was documented in 19 of 131 patients (14.5%) post Gd-EOB-DTPA-enhanced MRI. Gd-EOB-DTPA-enhanced MRI was superior in the diagnosis and therapeutic management of focal liver lesions compared with CT. (orig.)

  13. Characterization of focal liver lesions with a new ultrasound contrast agent using continuous low acoustic power imaging: comparison with contrast enhanced spiral CT; Caratterizzazione delle lesioni focali epatiche con mezzo di contrasto ecografico e metodica di imaging continuo a basso indice meccanico: paragone con la TC spirale con contrasto

    Energy Technology Data Exchange (ETDEWEB)

    Passamonti, Matteo; Vercelli, Alessandro; Azzaretti, Andrea; Rodolico, Giuseppe; Calliada, Fabrizio [Ospedale Maggiore di Lodi, U. O. Radiologia, Lodi (Italy)

    2005-04-01

    Purpose: To evaluate the concordance of the enhancement patterns of a new ultrasound contrast agent (SonoVue) with those obtained with dual-phase contrast-enhanced spiral CT (CE-CT) in the characterization of focal liver lesions (FLLs). Materials and methods: Sitxty-two patients with focal liver lesions discovered at ultrasound and also studied with CECT underwent contrast-enhanced ultrasound using continuous low acoustic power imaging after receiving a 2.4 ml bolus of the new US contrast agent SonoVue, consisting of a dispersion of sulphur hexafluoride micro bubbles. The examinations were made using ATL HDI-5000, Acuson SEQUOIA and Aloka 5500 Prosound ultrasound systems with 5.2 MHz curved-array probes. The concordance between US and CE-CT images was evaluated on site by two radiologists blinded to CT results. The FLLs were assessed in the arterial (20 s after CM injection), portal (after 45-60 s) and late (after 120 s) phases for: 1) presence/absence of enhancement, 2) distribution of enhancement (homogenous or target distribution, centripetal or centrifugal flow, and other), 3) qualitative enhancement pattern (hyper-echoic, hypoechoic, or isoechoic) versus normal liver parenchyma. Results: The concordance between SonoVue-enhanced US and CE-CT was 85%. Moreover during portal venous phase with CEUS it was possible to differentiate between malignancy or benignity of 91% of lesions. Conclusions: The preliminary data obtained in this study suggest that continuous low acoustic power imaging and contrast-enhanced US show similar results to CT in contrast distribution and contrast enhancement patterns. [Italian] Scopo: Valutare la concordanza dei pattern di enhancement ottenuti con un nuovo ecocontrasto, SonoVue, con i noti pattern contrastografici della TC spirale multifasica nella caratterizzazione delle lesioni focali epatiche. Materiale e metodi: Sessantadue pazienti con lesioni focali epatiche diagnosticate ad un esame ecografico e con esame TC con contrasto, sono

  14. Radiation dose evaluation in 64-slice CT examinations with adult and paediatric anthropomorphic phantoms

    OpenAIRE

    Fujii, K; Aoyama, T; Yamauchi-Kawaura, C; Koyama, S; Yamauchi, M; Ko, S; Akahane, K; Nishizawa, K

    2009-01-01

    The objective of this study was to evaluate the organ dose and effective dose to patients undergoing routine adult and paediatric CT examinations with 64-slice CT scanners and to compare the doses with those from 4-, 8- and 16-multislice CT scanners. Patient doses were measured with small (

  15. Noninvasive detection of coronary abnormalities in pediatric patients with Kawassaki disease using multi-slice spiral CT

    International Nuclear Information System (INIS)

    Hou Yang; Guo Wenli; Yue Yong; Chen Liying; Guo Qiyong; Yu Xianyi; Wang Hong

    2006-01-01

    Objective: To evaluate the feasibility and value of detecting coronary artery lesions in Kawasaki disease using multi-slice computed tomography (MSCT). Methods: Thirty-four pediatric patients underwent 16-slice or 64-slice CT coronary, angiography. 18 patients were also examined with 2 dimension echocardiography (2DE). In all cases, visibility of coronary artery segment was recorded. The diameter of the LCA, RCA were measured in MSCTA and compared with 2DE. Correlation coefficient of dimension and coincidence rate of two methods were calculated. Results: Coronary artery lesions were found in 14 patients (22 branches) of the 34 cases with KD on MSCT. Six cases were dialated, 3 cases were dialated with aneurysms, 2 cases had aneurysms without dialation. Coronary artery stenosis in 1 eases, calcification in 2 cases. Three cases had multiple aneurysms with the presence of alternate stenosis that made the artery a bead-like appearance. CC of LM and RCA were 0.85, 0.91, respectively (P>0.05). Three coronary artery aneurysm in the distal RCA was missed by 2DE. MSCT could not detect slight or moderate mitral regurgitation in 2 patients and artery wall thickening in 5 patients. Conclusion: MSCT would be an effective complementary or alternative method for CDEC to evaluate coronary artery lesions non-invasively in pediatric patients with Kawasaki disease. (authors)

  16. Radiation Exposure in X-Ray and CT Examinations

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Radiation Dose in X-Ray and CT Exams What ... page for more information. top of page Measuring radiation dosage The scientific unit of measurement for radiation ...

  17. Screening for early lung cancer with low-dose spiral computed tomography: results of annual follow-up examinations in asymptomatic smokers

    International Nuclear Information System (INIS)

    Diederich, Stefan; Thomas, Michael; Semik, Michael; Lenzen, Horst; Roos, Nikolaus; Weber, Anushe; Heindel, Walter; Wormanns, Dag

    2004-01-01

    The aim of this study was analysis of incidence results in a prospective one-arm feasibility study of lung cancer screening with low-radiation-dose spiral computed tomography in heavy smokers. Eight hundred seventeen smokers (≥40 years, ≥20 pack years of smoking history) underwent baseline low-dose CT. Biopsy was recommended in nodules >10 mm with CT morphology suggesting malignancy. In all other lesions follow-up with low-dose CT was recommended. Annual repeat CT was offered to all study participants. Six hundred sixty-eight (81.8%) of the 817 subjects underwent annual repeat CT with a total of 1735 follow-up years. Follow-up of non-calcified nodules present at baseline CT demonstrated growth in 11 of 792 subjects. Biopsy was performed in 8 of 11 growing nodules 7 of which represented lung cancer. Of 174 new nodules, 3 represented lung cancer. The 10 screen-detected lung cancers were all non-small cell cancer (6 stage IA, 1 stage IB, 1 stage IIIA, 2 stage IV). Five symptom-diagnosed cancers (2 small cell lung cancer: 1 limited disease, 1 extensive disease, 3 central/endobronchial non-small cell lung cancer, 2 stage IIIA, 1 stage IIIB) were diagnosed because of symptoms in the 12-month interval between two annual CT scans. Incidence of lung cancer was lower than prevalence, screen-detected cancers were smaller, and stage I was found in 70% (7 of 10) of screen-detected tumors. Only 27% (4 of 15) of invasive procedures was performed for benign lesions; however, 33% (5 of 15) of all cancers diagnosed in the population were symptom-diagnosed cancers (3 central NSCLC, all stage III, 2 SCLC) demonstrating the limitations of CT screening. (orig.)

  18. Colour-coded three-dimensional reconstruction from spiral CT data sets: Improvement from the physical point of view

    International Nuclear Information System (INIS)

    Wunderlich, A.P.; Lenz, M.; Kirsten, R.; Gerhardt, P.

    1993-01-01

    This paper demonstrates the possibility of improving the spatial depth impression of colour-coded three-dimensional reconstructions by modulation of colour saturation. Patients were observed with spiral computed tomography (slice thickness 10 mm, table feed 10 mm/s, reconstruction of overlapping axial images at 2 mm increment). Interesting anatomical and pathological objects (vessels, organs, tumours, metastases) were segmented, colour-coded, and reconstructed three-dimensionally. Spatial depth impression of the coloured objects could be improved by modulating not only the brightness, but also the colour saturation. (orig.) [de

  19. Added diagnostic benefit of 16-row whole-body spiral CT in patients with multiple trauma differentiated by region and injury severity according to the ATLS registered concept

    International Nuclear Information System (INIS)

    Maurer, M.H.; Knopke, S.; Schroeder, R.J.

    2008-01-01

    Purpose: to determine the added diagnostic benefit of using MS-CT in multiple trauma patients differentiated by severity of injury and affected body region. Materials and methods: a retrospective analysis was performed of the 16-row whole-body spiral CT findings in 275 multiple trauma patients (73% men, 27% women; age 39.6 ± 18.9 years) with regard to additional findings and new findings obtained with CT compared to the findings obtained by conventional projection radiography and abdominal ultrasound in the emergency room. The additional and new findings were differentiated by body region (head, face, chest, pelvis, abdomen, spine) and the degree of severity according to the three classes of injuries distinguished by the ATLS registered concept (class 1: simple injury, class 2: potentially life threatening, class 3: immediately life threatening). Results: a total of 921 additional findings (findings potentially relevant for further diagnosis and therapy in addition to the findings obtained by conventional radiography or ultrasound) were obtained by MS-CT in all patients. The distribution by number of patients and body region was as follows: 22 neck, 76 face, 125 chest, 112 abdomen, 50 pelvis, and 91 spine. Most additional findings were categorized as potentially life threatening (ATLS class 2). In addition, there were 439 completely new findings, involving the head in 128 patients (mostly ATLS class 3), the face in 18, the chest in 47, the abdomen in 26, and the spine in 9 patients. Most new findings involving the face, abdomen, and spine were ATLS class 2 injuries. (orig.)

  20. Real practice radiation dose and dosimetric impact of radiological staff training in body CT examinations.

    Science.gov (United States)

    Paolicchi, Fabio; Faggioni, Lorenzo; Bastiani, Luca; Molinaro, Sabrina; Caramella, Davide; Bartolozzi, Carlo

    2013-04-01

    To evaluate the radiation dose of the main body CT examinations performed routinely in four regional diagnostic centres, the specific contribution of radiologists and technologists in determining CT dose levels, and the role of radiological staff training in reducing radiation doses. We retrospectively evaluated the radiation dose in terms of dose-length product (DLP) values of 2,016 adult CT examinations (chest, abdomen-pelvis, and whole body) collected in four different centres in our region. DLP values for contrast-unenhanced and contrast-enhanced CT examinations performed at each centre were compared for each anatomical area. DLP values for CT examinations performed before and after radiological staff training were also compared. DLP values for the same CT examinations varied among centres depending on radiologists' preferences, variable training of technologists, and diversified CT image acquisition protocols. A specific training programme designed for the radiological staff led to a significant overall reduction of DLP values, along with a significant reduction of DLP variability. Training of both radiologists and technologists plays a key role in optimising CT acquisition procedures and lowering the radiation dose delivered to patients. • The effective dose for similar CT examinations varies significantly among radiological centres. • Staff training can significantly reduce and harmonise the radiation dose. • Training of radiologists and technologists is key to optimise CT acquisition protocols.

  1. Reducing radiation dose in 64-row spiral CT coronary angiography: study based on individualized scan dosage protocol

    International Nuclear Information System (INIS)

    Kang Deqiang; Zhao Jing; Peng Nan; Hua Haiqin; Li Chao; Guo Ying; Shen Yun

    2012-01-01

    Objective: To investigate the methods of reducing radiation dose in CT coronary angiography through optimizing individualized scan dosage protocol. Methods: Two hundred patients (group A) underwent coronary CTA examination which was performed with fixed 120 kV and variable mA according to their BMI. The mA was set as 150-300 mA (BMI < 18.5 kg/m2), 300-500 mA (18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 ), and 500-800 mA (BMI ≥ 25.0 kg/m 2 ). When all examinations were finished, a linear regression was employed to analyze the correlation between mA and BMI, body surface (Suf), image noise (SD) respectively. The results of the analysis were used to formulate a regression equation, which was further used to establish a table list for quick search on how much mA that individualized coronary CTA scan would need. Another 200 patients (group B) enrolled for the individualized scan were scanned under new protocol that previous study established. The tube voltage was 100 and 120 kV. The tube current was variable according to the data in the table list. One-way ANOVA and Kruskal-wallis H test were used for statistics. Results: Regression equation between mA and BMI, Suf, SD was: mA =17.984 × BMI + 169.149 × Suf-2.282 × SD-361.039. The SD (group A: 32.08 ± 5.80, group B: 28.60±4.47), dose index volume (CTDI vol ) [group A: (41.97 ± 11.37) mGy, group B: (33.18±10.07) mGy], effective dose(ED) [group A: (10.91 ±3.07) mSy, group B: (8.83 ±2.72)mSv] had significant differences between the two groups (F=43.45, 63.71, 49.07 respectively, P<0.01 for all). The SD and ED results obtained in group B were better than those in group A. Conclusion: Better performances were obtained when BMI combined Suf was used as a new individualized protocol than when BMI was used only, which means good image quality and lower radiation dosage in coronary CTA examination. (authors)

  2. [3-D imaging with a mobile surgical image enhancement equipment (ISO-C-3D). Initial examples of fracture diagnosis of peripheral joints in comparison with spiral CT and conventional radiography].

    Science.gov (United States)

    Kotsianos, D; Rock, C; Euler, E; Wirth, S; Linsenmaier, U; Brandl, R; Mutschler, W; Pfeifer, K J

    2001-09-01

    To analyze a prototype mobile C-arm image amplifier (Iso-C3D) in the evaluation of different joint fractures of the upper and lower limbs using multiplanar reconstruction (MPR). Different cadaver joint specimens (n = 14) were examined with a prototype (Iso-C3D, Siemens AG, Erlangen, Germany), plain radiographs (CR), and spiral computed tomography (CT). The motorized C-arm provides fluoroscopic images during a 190 degrees orbital rotation computing a 119-mm data cube. These three-dimensional data sets yielded MPR images, which were evaluated by two readers for the detection and extent of fracture lines. Initial data show that fractures were easily depicted and correctly classified on MPR images with the Iso-C3D and that there was no difference between the Iso-C and CT in the detection of fractures. The preliminary results suggest a remarkably good detection of joint fractures with the Iso-C3D. Studies in an adequate number of patients are required to elucidate whether these promising results can also be obtained in a clinical setting.

  3. Real practice radiation dose and dosimetric impact of radiological staff training in body CT examinations

    OpenAIRE

    Paolicchi, Fabio; Faggioni, Lorenzo; Bastiani, Luca; Molinaro, Sabrina; Caramella, Davide; Bartolozzi, Carlo

    2013-01-01

    Objectives To evaluate the radiation dose of the main body CT examinations performed routinely in four regional diagnostic centres, the specific contribution of radiologists and technologists in determining CT dose levels, and the role of radiological staff training in reducing radiation doses. Methods We retrospectively evaluated the radiation dose in terms of dose-length product (DLP) values of 2,016 adult CT examinations (chest, abdomen-pelvis, and whole body) collected in four different c...

  4. Spiral symmetry

    CERN Document Server

    Hargittai, Istvan

    1992-01-01

    From the tiny twisted biological molecules to the gargantuan curling arms of many galaxies, the physical world contains a startling repetition of spiral patterns. Today, researchers have a keen interest in identifying, measuring, and defining these patterns in scientific terms. Spirals play an important role in the growth processes of many biological forms and organisms. Also, through time, humans have imitated spiral motifs in their art forms, and invented new and unusual spirals which have no counterparts in the natural world. Therefore, one goal of this multiauthored book is to stress the c

  5. The investigation of the lateral atlanto-dental interval of atlanto-axial joint by multi-slice spiral CT

    International Nuclear Information System (INIS)

    Cui Wei; Peng Lei; Wang Jincai; Liu Jihua; Feng Weihua

    2010-01-01

    Objective: To explore imaging features of the lateral atlanto-dental interval (LADI) of atlanto-axial joint and its value in the diagnosis of atlanto-axial joint dislocation/subluxation. Methods: Two hundred and forty healthy volunteers without atlanto-axial joint dysfunction and 32 patients with torticollis and/or functional impairment at atlanto-axial.joint were enrolled into this study. All subjects were examined with multi-slice CT in both neutral and max rotation positions to the left/right. Clinical endpoints including VBLADI, variance range of the VBLADI and asymmetric conditions were evaluate. χ 2 test is used to evaluate the variance of incidence of bilateral LADI asymmetry in different age groups, Pearson-test (2-tailed) is used to evaluate the correlation between VBLADI and rotary function of atlanto-axial joint, precise test of fourfold table is used to compare normal group with patient groups. Results: (1) In the normal control group: asymmetry of bilateral LADI were observed in 204 among 240 (85.00%) healthy volunteers including 60 youngsters ( 95% of ∣ VBLADI ∣ were 0.850 mm, 2.450 mm in the young ( 95% in the young and in the adult respectively. There was no correlation between VBLADI(-2.146 to 2.114 mm, Median 0.000 mm) and LA (22.949° to 44.649°, Median 34.500°), RA (25.284° to 45.334°, Median 35.300°), VLRA (-11.643° to 8.623°, median 0.000°) respectively in normal people (r=-0.030, -0.005, 0.026, P>0.05). (2) In the study with 32 patients including 25 youngsters ( 95% in group AALSD and group AACD than in abnormal group (P<0.01), but there is no difference between group AARD and normal group (P=0.738). Conclusion: The imaging finding of 'asymmetry of bilateral LADI' may be either a physiological variation or a pathological condition, clinical manifestations and other imaging findings should be evaluated to make a diagnosis. (authors)

  6. The clinical evaluation of CT and radionuclide examination in renal diseases

    International Nuclear Information System (INIS)

    Kutani, Wataru; Ishida, Hirofumi; Shirakawa, Shigetoshi; Shintaku, Takao; Funaki, Ryo

    1980-01-01

    One hundred and twelve cases of renal diseases were studied by computed tomography (CT) using EMI 5005/12. Of them, 60 were examined by both CT and renal scintigraphy, and comparatively evaluated. The CT units were checked before and after the contrast enhancement. Renal scintigrams were obtained by gamma cameras (PHO/GAMMA HP 6406, PHO/GAMMA LFOV) using 99 M Tc-DMSA. CT was especially useful in diagnosing the renal cysts and the hydronephrosis. Cysts in other organs (liver, spleen and pancreas) were simultaneously ascertained in polycystic diseases. CT was not helpful in diagnosing nephritis and diabetic nephropathy. Floating kidney and horse-shoe kidney were difficult to diagnose with CT. The renal scintigram was the reflection of the renal function, and was relatively more useful than CT in diagnosing horse-shoe kidney, floating kidney and nephritis, while it was not useful for non-functioning kidneys. (author)

  7. Spiral finned crucible pot

    Science.gov (United States)

    Soemowidagdo, Arianto Leman; Tiwan, Widarto, Ardian, Aan

    2018-02-01

    Innovation on a crucible furnace to increase its efficiency in aluminum melting has been done. The innovation was a spiral finned crucible pot. The inclination of the spiral finned was vary of 5, 10, 15, and 20 degrees. The spiral finned effects was determined from the performance test result. A crucible pot without fin was also tested as a control. The crucible pot was examined at the same process condition. The crucible pot with the inclined fin of 10 degrees gives an optimum performance. It gives effective heating rate so that more efficient in LPG consumption. Therefore it saves energy in the aluminum melting process.

  8. Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population

    Directory of Open Access Journals (Sweden)

    Mahmoud Jabalameli

    2016-04-01

    Full Text Available Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational alignment in preoperative CT scans of Iranian patients who were candidates for total knee arthroplasty and the effects of age, gender, and knee alignment on these relationships. Methods: One hundred and eight cases who were admitted to two university hospitals for total knee arthroplasty were included in this study. The rotation of the distal femur was evaluated using single axial CT images through the femoral epicondyle. Four lines were drawn digitally in this view: anatomical and surgical transepicondylar axes, posterior condylar axis and the Whiteside anteroposterior line. The alignment of the extremity was evaluated in the standing alignment view. Then the angles were measured along these lines and their relationship was evaluated. Results: The mean angle between the anatomical transepicondylar axis and posterior condylar axis and between the surgical transepicondylar axis and posterior condylar axis were 5.9 ± 1.6 degrees and 1.6±1.7 degrees respectively. The mean angle between the Whiteside’s anteroposterior line and the line perpendicular to the posterior condylar axis was 3.7±2.1 degrees. Significant differences existed between the two genders in these relationships. No significant correlation between the age of patients and angles of the distal femur was detected. The anatomical surgical transepicondylar axis was in 4.3 degrees external rotation in relation to the surgical transepicondylar axis. Conclusion: Preoperative CT scanning can help accurately determine rotational landmarks of the distal femur. If one of the reference axes cannot be

  9. The diagnostic importance of the recognition of the inferior Vena cava abnormalities on CT-examinations

    International Nuclear Information System (INIS)

    Gouliamos, A.; Striggaris, K.; Haliasos, N.; Vlahos, N.; Pontifex, G.

    1981-01-01

    Two unusual variations of the Vena cava inferior, as shown by CT examinations, are reported and characteristic X-rays, as well as CT scans, are presented. The first case shows an IVC course to the left of the aorta and the second case absence of the intrahepatic portion of the IVC with azygos continuation. Difficulties in the differential diagnosis are analyzed and discussed, both demonstrated by plain X-rays and CT scans. (orig.) [de

  10. Delayed traumatic intracranial hematoma. In view of serial CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hiroki (Tokyo Medical and Dental Univ. (Japan). School of Medicine)

    1984-03-01

    CT was performed serially within 24 hours after head injury in 64 patients having Glasgow Coma Scale of 14 or less or cranial fracture shown on roentgenogram. Delayed traumatic extradural hematoma was observed within 7-12 hours after head injury in 6 cases (9.4%). This was prominent in the frontal and occipital regions (67%). Good recovery was seen in 83.3%. Delayed traumatic intracerebral hematoma was observed within 6-24 hours after head injury in 17 cases (26.6%). This higher incidence was related to contre coup injury. Conservative treatment was possible in 14 of the 17 patients (82.4%), showing good recovery in 70%.

  11. Examination of CT-AEC when the positioning changes after planning of CT scanning

    International Nuclear Information System (INIS)

    Esaki, Tooru; Yamazaki, Shoichi

    2009-01-01

    CT-automatic exposure control (AEC) controls tube current collecting information of the subject from positioning shooting. Because of this, we consider that CT-AEC does not get to operate properly if the body position of the test subject changes after the positioning shooting. However, we often experience in body positions of test subjects after the positioning shooting. In cases like this, we measured by using a phantom again to see how they affect the tube current value and standard deviation (SD) value comparing them to the normal scan where a body position does not change. As a result of the measurement, there was an impact on CT-AEC that optimization of tube current becomes insufficient if the body position of a test subject changes. As the image quality is deteriorated and radiation exposure increases because of this, taking positioning shooting again is required on the part of users and it's desirable on the part of manufacturers to develop CT-AEC that can be controlled with high accuracy. (author)

  12. Examination of venous tumor thrombus with colorectal cancer by enhanced CT

    International Nuclear Information System (INIS)

    Sato, Osamu; Kiba, Maki; Tazoe, Jun

    2010-01-01

    Recently, multi detector row CT (MDCT) has been largely used and enabled to detect drainage vessels of tumors. Then we tried examining the ratio, by using enhanced CT, of the cases that has venous tumor thrombus with colorectal cancer, and found the 3 cases out of 176 to be venous tumor thrombus of mesenteric veins in advanced stage. (author)

  13. Investigation of influence of 16-slice spiral CT electrocardiogram-controlled dose modulation on exposure dosage and image quality of cardiac CT imaging under simulated fluctuant heart rate

    International Nuclear Information System (INIS)

    Yin Yan; Chen Jie; Chai Weiming; Hua Jia; Gao Na; Xu Jianrong; Shen Yun

    2008-01-01

    Objective: To investigate the influence of electrocardiogram (ECG)-controlled dose modulation on exposure dosage and image quality of cardiac CT imaging in a cardiac phantom with simulated fluctuant heart rate. Methods: The basal heart rate of the cardiac pulsating phantom was set as 60 bpm, the experimental situations were divided as 6 groups according to different heart rates. The cardiac imaging was performed on the cardiac phantom when the ECG-controlled dose modulation was firstly turned off. The exposure dosage of each scan sequence was documented. The standard deviation of the CT values of the phantom was measured on the central slice after coronal reformation of the raw data. The quality of 2D and 3D images were scored. Then cardiac imaging was performed when ECG modulation was on and set as four groups according to different modulation parameters. All the data were documented as before. The results from the five groups with and without ECG modulation current were analyzed by F test and comparative rank sum test using the statistical software SPSS 10.0. Results: Statistical analysis showed no significant difference (P>0.05) between the SNR of images (SD value was 27.78 and 26.30) from the groups that full mA output at wide reconstruction phase (69%-99%) when the heart rate was fluctuant(≥7.5 bpm). There was also no significant difference (P>0.05) between the quality of the 2D and 3D images. But there was a significant difference (P 12.5 bpm, the exposure dosage would increase obviously (from 0.6 to 1.7 mSv). Conclusion: For cardiac imaging with 16-slice row CT, the application of ECG modulated current can effectively reduce the exposure dosage without compromising the image quality even if heart rate was fluctuant. (authors)

  14. ASSESSMENT OF EFFECTIVE DOSE FROM CONE BEAM CT IMAGING IN SPECT/CT EXAMINATION IN COMPARISON WITH OTHER MODALITIES.

    Science.gov (United States)

    Tonkopi, Elena; Ross, Andrew A

    2016-12-01

    The aim of this study was to assess radiation dose from the cone beam computed tomography (CBCT) component of single photon emission tomography/computed tomography (SPECT/CT) examinations and to compare it with the radiopharmaceutical related dose as well as dose from multidetector computed tomography (MDCT). Effective dose (ED) from computed tomography (CT) was estimated using dose-length product values and anatomy-specific conversion factors. The contribution from the SPECT component was evaluated using ED per unit administered activity for the radiopharmaceuticals listed in the International Commission on Radiological Protection Publications 80 and 106. With the exception of cardiac studies (0.11 mSv), the CBCT dose (3.96-6.04 mSv) was similar to that from the radiopharmaceutical accounting for 29-56 % of the total ED from the examination. In comparison with MDCT examinations, the CBCT dose was 48 and 42 % lower for abdomen/pelvis and chest/abdomen/pelvis scans, respectively, while in the chest the CBCT scan resulted in higher dose (23 %). Radiation dose from the CT component should be taken into consideration when evaluating total SPECT/CT patient dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Interval lung cancer after a negative CT screening examination: CT findings and outcomes in National Lung Screening Trial participants

    Energy Technology Data Exchange (ETDEWEB)

    Gierada, David S. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, Box 8131, St. Louis, MO (United States); Pinsky, Paul F. [National Cancer Institute, Bethesda, MD (United States); Duan, Fenghai [Brown University School of Public Health, Department of Biostatistics and Center for Statistical Sciences, Providence, RI (United States); Garg, Kavita [University of Colorado School of Medicine, Mail Stop F726, Box 6510, Aurora, CO (United States); Hart, Eric M. [Northwestern University, Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Kazerooni, Ella A. [University of Michigan Health System, Department of Radiology, Ann Arbor, MI (United States); Nath, Hrudaya; Watts, Jubal R. [University of Alabama at Birmingham School of Medicine, Department of Radiology-JTN370, Birmingham, AL (United States); Aberle, Denise R. [David Geffen School of Medicine at UCLA, Department of Radiological Sciences, Los Angeles, CA (United States)

    2017-08-15

    This study retrospectively analyses the screening CT examinations and outcomes of the National Lung Screening Trial (NLST) participants who had interval lung cancer diagnosed within 1 year after a negative CT screen and before the next annual screen. The screening CTs of all 44 participants diagnosed with interval lung cancer (cases) were matched with negative CT screens of participants who did not develop lung cancer (controls). A majority consensus process was used to classify each CT screen as positive or negative according to the NLST criteria and to estimate the likelihood that any abnormalities detected retrospectively were due to lung cancer. By retrospective review, 40/44 cases (91%) and 17/44 controls (39%) met the NLST criteria for a positive screen (P < 0.001). Cases had higher estimated likelihood of lung cancer (P < 0.001). Abnormalities included pulmonary nodules ≥4 mm (n = 16), mediastinal (n = 8) and hilar (n = 6) masses, and bronchial lesions (n = 6). Cancers were stage III or IV at diagnosis in 32/44 cases (73%); 37/44 patients (84%) died of lung cancer, compared to 225/649 (35%) for all screen-detected cancers (P < 0.0001). Most cases met the NLST criteria for a positive screen. Awareness of missed abnormalities and interpretation errors may aid lung cancer identification in CT screening. (orig.)

  16. Radiation dose evaluation in 64-slice CT examinations with adult and paediatric anthropomorphic phantoms.

    Science.gov (United States)

    Fujii, K; Aoyama, T; Yamauchi-Kawaura, C; Koyama, S; Yamauchi, M; Ko, S; Akahane, K; Nishizawa, K

    2009-12-01

    The objective of this study was to evaluate the organ dose and effective dose to patients undergoing routine adult and paediatric CT examinations with 64-slice CT scanners and to compare the doses with those from 4-, 8- and 16-multislice CT scanners. Patient doses were measured with small (effective doses were computed. For the adult phantom, organ doses (for organs within the scan range) and effective doses were 8-35 mGy and 7-18 mSv, respectively, for chest CT, and 12-33 mGy and 10-21 mSv, respectively, for abdominopelvic CT. For the paediatric phantom, organ and effective doses were 4-17 mGy and 3-7 mSv, respectively, for chest CT, and 5-14 mGy and 3-9 mSv, respectively, for abdominopelvic CT. Doses to organs at the boundaries of the scan length were higher for 64-slice CT scanners using large beam widths and/or a large pitch because of the larger extent of over-ranging. The CT dose index (CTDI(vol)), dose-length product (DLP) and the effective dose values using 64-slice CT for the adult and paediatric phantoms were the same as those obtained using 4-, 8- and 16-slice CT. Conversion factors of DLP to the effective dose by International Commission on Radiological Protection 103 were 0.024 mSvmGy(-1)cm(-1) and 0.019 mSvmGy(-1)cm(-1) for adult chest and abdominopelvic CT scans, respectively.

  17. Calculation of Organ Doses for a Large Number of Patients Undergoing CT Examinations.

    Science.gov (United States)

    Bahadori, Amir; Miglioretti, Diana; Kruger, Randell; Flynn, Michael; Weinmann, Sheila; Smith-Bindman, Rebecca; Lee, Choonsik

    2015-10-01

    The objective of our study was to develop an automated calculation method to provide organ dose assessment for a large cohort of pediatric and adult patients undergoing CT examinations. We adopted two dose libraries that were previously published: the volume CT dose index-normalized organ dose library and the tube current-exposure time product (100 mAs)-normalized weighted CT dose index library. We developed an algorithm to calculate organ doses using the two dose libraries and the CT parameters available from DICOM data. We calculated organ doses for pediatric (n = 2499) and adult (n = 2043) CT examinations randomly selected from four health care systems in the United States and compared the adult organ doses with the values calculated from the ImPACT calculator. The median brain dose was 20 mGy (pediatric) and 24 mGy (adult), and the brain dose was greater than 40 mGy for 11% (pediatric) and 18% (adult) of the head CT studies. Both the National Cancer Institute (NCI) and ImPACT methods provided similar organ doses (median discrepancy variety of CT-related studies including retrospective epidemiologic studies and CT dose trend analysis studies.

  18. Three-phase CT examination of the pancreatobiliary region using multislice CT with 1-mm collimation

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Ikeda, Mitsuru; Suzuki, Koujiro; Iwano, Shingo; Satake, Hiroko; Ota, Toyohiro; Ishigaki, Takeo

    2005-01-01

    The purpose of this study was to evaluate the degree of contrast enhancement and accuracy of imaging of the circulatory phase in the first-pass, second-pass, and third-pass acquisitions in the pancreato-biliary region with 1-mm collimation obtained by multislice computed tomography (CT). In 53 patients, two sequential acquisitions from the porta hepatis to the pancreas were performed during a single breath-hold, followed by a third-pass acquisition including the liver beginning 15 sec after the second-pass acquisition. Contrast enhancement in each acquisition was measured in the aorta, portal vein and its branches, and pancreas. Four experienced radiologists graded using four-point scoring whether or not each acquisition was appropriate for imaging of the arterial phase, pancreatic phase, and portal venous phase. Aortic enhancement was highest at the beginning of the second-pass acquisition. The portal and splenic veins and pancreas showed maximum enhancement in the second-pass acquisition, while the superior mesenteric vein showed maximum enhancement in the third-pass acquisition. In the visual assessment, significantly higher grades were achieved in the first-pass, second-pass, and third-pass acquisitions with regard to imaging of the arterial phase, pancreatic phase, and portal venous phase, respectively. Multislice CT permits the acquisition of three distinct circulatory phases (arterial, pancreatic, and portal venous phases) in the pancreatobiliary region with 1-mm collimation. (author)

  19. An estimation of the annual effective dose to the Canadian population from medical CT examinations.

    Science.gov (United States)

    Chen, Jing; Moir, Deborah

    2010-06-01

    This study was carried out to assess the annual per capita effective dose from medical diagnostic procedures using computed tomography (CT) in Canada. Relevant data concerning the nature and the frequency of various diagnostic CT examinations were obtained from the reports on Medical Imaging in Canada and Diagnostic Services in Ontario. Doses associated with examinations of different types were based primarily on typical effective doses used in the National Council on Radiation Protection and Measurements Report 160 with considerations of limited dose information surveyed in Canada. The results show that the per capita annual effective dose from diagnostic CT exams was 0.74 mSv in 2006, up from 0.19 mSv in 1991. This significant increase in population radiation dose from CT scans is due mainly to a more than doubling in the examination rate and to a higher radiation dose per procedure from the newer generation of multi-detector CTs.

  20. Diagnostic Yield of Recommendations for Chest CT Examination Prompted by Outpatient Chest Radiographic Findings

    Science.gov (United States)

    Harvey, H. Benjamin; Gilman, Matthew D.; Wu, Carol C.; Cushing, Matthew S.; Halpern, Elkan F.; Zhao, Jing; Pandharipande, Pari V.; Shepard, Jo-Anne O.

    2015-01-01

    Purpose To evaluate the diagnostic yield of recommended chest computed tomography (CT) prompted by abnormalities detected on outpatient chest radiographic images. Materials and Methods This HIPAA-compliant study had institutional review board approval; informed consent was waived. Reports of all outpatient chest radiographic examinations performed at a large academic center during 2008 (n = 29 138) were queried to identify studies that included a recommendation for a chest CT imaging. The radiology information system was queried for these patients to determine if a chest CT examination was obtained within 1 year of the index radiographic examination that contained the recommendation. For chest CT examinations obtained within 1 year of the index chest radiographic examination and that met inclusion criteria, chest CT images were reviewed to determine if there was an abnormality that corresponded to the chest radiographic finding that prompted the recommendation. All corresponding abnormalities were categorized as clinically relevant or not clinically relevant, based on whether further work-up or treatment was warranted. Groups were compared by using t test and Fisher exact test with a Bonferroni correction applied for multiple comparisons. Results There were 4.5% (1316 of 29138 [95% confidence interval {CI}: 4.3%, 4.8%]) of outpatient chest radiographic examinations that contained a recommendation for chest CT examination, and increasing patient age (P history (P = .001) were associated with increased likelihood of a recommendation for chest CT examination. Of patients within this subset who met inclusion criteria, 65.4% (691 of 1057 [95% CI: 62.4%, 68.2%) underwent a chest CT examination within the year after the index chest radiographic examination. Clinically relevant corresponding abnormalities were present on chest CT images in 41.4% (286 of 691 [95% CI: 37.7%, 45.2%]) of cases, nonclinically relevant corresponding abnormalities in 20.6% (142 of 691 [95% CI: 17

  1. Water enema CT examination of rectum cancer by reduced amount of water

    Energy Technology Data Exchange (ETDEWEB)

    Palko, A.; Gyulai, Cs.; Fedinecz, N. [Szeged Univ. (Hungary). Dept. of Radiology; Balogh, A. [Szeged Univ. (Hungary). Dept. of Surgery; Nagy, F. [Szeged Univ. (Hungary). Faculty of General Medicine

    2000-11-01

    To define whether volume of water, administered during water enema CT (WE-CT) for local staging of rectal cancer, may be reduced without compromising the diagnostic value of the examination. Materials and Methods: 29 patients with rectum cancer underwent preoperative WE-CT. Contrast-enhanced CT (equilibrium phase) measurements were performed after i.v. injection of smooth muscle relaxant and rectal administration of 400 - 500 ml lukewarm tap water. Quality of the obtained scans was evaluated and the images were analyzed for depth of tumor invasion. Results of the CT examinations were compared to findings at surgery. Results: Despite reduced dose of water enema, 19/29 examinations were of excellent quality, 6/29 good, and 4/29 poor, but still diagnostic. We achieved sensitivity (90.1), specificity (70.1) and accuracy (86.2) in differentiating tumors confined to the bowel wall from those extending beyond it. Conclusion: Large volume of water enema administered during CT examination of the rectum may cause complaints and increases the risk of complications. Our results prove that using lower amount of water does not impair the quality of examination and accuracy of local staging of rectum carcinomas. (orig.) [German] Beurteilen, ob die in der Hydro-CT (H-CT) rektal applizierte Wassermenge reduziert werden kann, ohne den diagnostischen Wert der Untersuchung im lokal-Staging des Rektumkarzinoms zu mindern. Material und Methode: 29 Patienten mit Rektumkarzinom wurden praeoperativ mit H-CT untersucht. Nach i.v. Praemedikation zur Darmparalyse wurden rektal ca. 400 - 500 ml lauwarmes Wasser appliziert, und i.v. kontrastverstaerkte CT-Untersuchungen durchgefuehrt. Die Qualitaet der CT-Scans und die Tiefe der invasion des Tumors in die Darmwand wurden analysiert. Die computertomographischen Befunde wurden mit den Operationsbefunden verglichen. Ergebnisse: Trotz der reduzierten Menge des Einlaufswassers, 19/29 Untersuchungen hatten ausgezeichnete, 6/29 gute, und 4/29 schwache

  2. Poor concordance of spiral CT (SCT) and high probability ventilation-perfusion (V/Q) studies in the diagnosis of pulmonary embolism (PE)

    International Nuclear Information System (INIS)

    Roman, M.R.; Angelides, S.; Chen, N.

    2000-01-01

    Full text: Despite its limitations, V/Q scintigraphy remains the favoured non-invasive technique for the diagnosis of pulmonary embolism (PE). PE is present in 85-90% and 30-40% of high and intermediate probability V/Q studies respectively. The value of spiral CT (SCT), a newer imaging modality, has yet to be determined. The aims of this study were to determine the frequency of positive SCT for PE in high and intermediate probability V/Q studies performed within 24hr apart. 15 patients (6M, 9F, mean age - 70.2) with a high probability study were included. Six (40%) SCT were reported as positive (four with emboli present in the main pulmonary arteries), seven as negative, one equivocal and one was technically sub-optimal. Pulmonary angiography was not performed in any patient. In all seven negative studies, the SCT was performed before the V/Q study. Of these, two studies were revised to positive once the result of the V/Q study was known, while, three others had resolving mismatch V/Q defects on follow-up studies (performed 5-14 days later); two of these three also had a positive duplex scan of the lower limbs. One other was most likely due to chronic thromboembolic disease. Only three patients had a V/Q scan prior to the SCT; all were positive for PE on both imaging modalities. Of 26 patients (11M, 15F, mean age - 68.5) with an intermediate probability V/Q study, SCT was positive in only two (8%). Thus the low detection rate of PE by SCT in this albeit small series, raises doubts as to its role in the diagnosis of PE. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  3. Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

    Science.gov (United States)

    Dhalisa, H.; Mohamad, A. S.; Rafidah, Z.

    2016-01-01

    This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dose to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.

  4. Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

    Energy Technology Data Exchange (ETDEWEB)

    Dhalisa, H., E-mail: dhalisa82@gmail.com; Rafidah, Z. [Kluster Oncology Science and Radiology, Advanced Medical Dental Institute, Universiti Sains Malaysia (USM), Bertam, Penang (Malaysia); Mohamad, A. S. [Department of Nuclear Medicine, National Cancer Institute, No 4 Jalan P7, Presint 7, Putrajaya (Malaysia)

    2016-01-22

    This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dose to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.

  5. Effective radiation doses of CT examinations in Japan: a nationwide questionnaire-based study

    Science.gov (United States)

    Kawaguchi, Ai; Kobayashi, Kenichi; Kobayashi, Masanao; Asada, Yasuki; Minami, Kazuyuki; Suzuki, Shoichi; Chida, Koichi

    2016-01-01

    Objective: The aims of this study were to estimate the effective radiation doses from CT examinations of both adults and children in Japan and to study the impact of various scan parameters on the effective doses. Methods: A questionnaire, which contained detailed questions on the CT scan parameters employed, was distributed to 3000 facilities throughout Japan. For each scanner protocol, the effective doses for head (non-helical and helical), chest and upper abdomen acquisitions were estimated using ImPACT CT Patient Dosimetry Calculator software v. 1.0.4 (St George's Hospital, London, UK). Results: The mean effective doses for chest and abdominal examinations using 80–110 kV were significantly lower than those using 120 kV. However, there was no statistically significant difference in the mean effective doses for head scans between facilities employing 80–110 kV and 120 kV. In chest and abdominal examinations, the mean effective doses using CT scanners from Western manufacturers [Siemens (Forchheim, Germany), Philips (Eindhoven, Netherlands) and GE Medical Systems (Milwaukee, WI)] were significantly lower than those of examinations using Japanese scanners [Hitachi (Kashiwa, Japan) and Toshiba (Otawara, Tochigi, Japan)], except for in paediatric chest examinations. Conclusion: The mean effective doses for adult head, chest and abdominal CT examinations were 2.9, 7.7 and 10.0 mSv, respectively, whereas the corresponding mean effective doses for paediatric examinations were 2.6, 7.1 and 7.7 mSv, respectively. Advances in knowledge: Facilities using CT scanners by Western manufacturers commonly adopt low-tube-voltage techniques, and low-tube-voltage CT may be useful for reducing the radiation doses to the patients, particularly for the body region. PMID:26647804

  6. Establishment of diagnostic reference levels for CT trunk examinations in the western region of Saudi Arabia

    International Nuclear Information System (INIS)

    Qurashi, Abdulaziz A.; Rainford, Louise A.; Foley, Shane J.

    2015-01-01

    Diagnostic reference levels (DRLs) are an important optimisation tool, which aid in identifying abnormally high dose levels. These are currently not available in Saudi Arabia, and this research aims to remedy this. CT dose data (DLP and CTDIvol) were collected for a minimum number of 10 adult patients of average size (60-80 kg) presenting for a range of CT examinations from public hospitals in the western region of Saudi Arabia. These include routine chest, high-resolution chest (HRCT), pulmonary angiography (CTPA), abdomen and pelvis (AP) and the combined chest, abdomen and pelvis (CAP) CT examinations. Mean values for each site were calculated, and the 75. percentile of DLP and CTDIvol was used as a basis for DRLs. Data for 550 patients were collected from 14 hospitals over a 7-month period. The rounded third-quartile CTDIvol and DLP were 18 mGy and 630 mGy cm -1 for chest CT, 20 mGy and 600 mGy cm -1 for HRCT, 18 mGy and 480 mGy cm -1 for CTPA, 15 mGy and 800 mGy cm -1 for AP, and 16 mGy and 1040 mGy cm -1 for CAP, respectively. Regional DRLs have been proposed from this study. Dose variations across CT departments have identified an urgent need for optimisation to improve distribution of observed doses for CT examinations. (authors)

  7. Acute renal colic: value of unenhanced spiral computed tomography compared with intravenous urography.

    Science.gov (United States)

    Wong, S K; Ng, L G; Tan, B S; Cheng, C W; Chee, C T; Chan, L P; Lo, H G

    2001-11-01

    The objective of this study was to compare the efficacy of plain spiral computed tomographic (CT) scan with intravenous urography (IVU) in the evaluation of patients with suspected urinary calculi/obstruction. Twenty consecutive patients with acute signs of renal colic were prospectively examined with unenhanced spiral CT followed by an IVU within the same day. The CT scans were reviewed jointly by 2 radiologists blinded to the IVU and a consensus was reached for each finding. The IVU was similarly reviewed by another 2 separate radiologists. Eleven of the 20 patients had signs of urinary obstruction on CT and IVU. Of these 11 patients, 7 had a ureteric calculus that was demonstrated on CT and IVU and 4 had a calculus that was demonstrated on CT only. Two patients had a urinary calculus seen on CT and IVU with no signs of urinary obstruction. One patient had a calculus seen on CT alone with no urinary obstruction. Two patients only had signs of urinary obstruction on CT. The remaining 4 cases had normal findings on CT and IVU. Unenhanced CT is more effective than IVU in identifying ureteric calculi and is equally effective in detecting urinary obstruction. CT is also useful in detecting secondary signs of obstruction even in the absence of any calculus.

  8. The “communication line” suggests occult posterior malleolar fracture associated with a spiral tibial shaft fracture

    International Nuclear Information System (INIS)

    Hou Zhiyong; Zhang Liping; Zhang Qi; Yao Shuangquan; Pan Jinshe; Irgit, Kaan; Zhang Yingze

    2012-01-01

    Objectives: To demonstrate radiographical characteristics of the relationship between distal spiral tibial shaft fractures and associated occult posterior malleolar fractures (PMF) that confirmed by CT and MRI. Materials and methods: X-rays for a ninety-six patients with spiral tibia fracture and associated PMF were reviewed. All patients additionally had an ankle CT. Patients with a negative CT scans underwent an ankle MRI. Radiographic observations included fracture location, characteristics, and a presence of a fracture line between the two injuries. Results: The spiral tibia fracture line was contiguous with PMF in 89 of 96 cases after evaluation with the CT and MRI. The line connecting the two injuries, which occurs between the medial inferior apex of the spiral tibia fracture line and the posterior superior apex of the PMF was identified as the “communication line”. In 47 of the 89 conjunction fractures, the “communication line” was detectable preoperatively and in 12 cases postoperatively by anteroposterior radiograph. By using the CT and MRI scans, we found that no “communication line” was present in only 7 cases. Conclusion: It is important to understand the nature of the association between distal spiral tibial shaft fractures and occult posterior malleolar fractures for optimal stabilization of the fracture and for appropriate rehabilitation. The “communication line” is a useful diagnostic clue for early recognition the occult PMF and alerts a closer evaluation of the lateral view and further CT examination.

  9. Exposure to radiation in whole body and skull CT examinations depending upon parameters determined by the technique of examination

    International Nuclear Information System (INIS)

    Fiebach, B.J.O.; Makoski, H.B.; Ewen, K.

    1983-01-01

    The article gives the organ doses for whole body CT examinations of the thoracic region, the upper abdomen, the mesogastric and pelvic regions as well as of the lumbar vertebral column and for CT scanning of the skull. The examinations were performed using in Alderson-Rando phantom with the whole body computer thomograph Somatom DR2 supplied by Siemens and with the skull computer tomograph Siretom 2000, also supplied by Siemens, It was found that the magnitude of radiation exposure of the patient depends not only on instrument-specific properties, but also to a very large measure on the examination parameters and techniques which can vary considerably from one clinic to another. (orig.) [de

  10. [Results of the Austrian CT dose study 2010: typical effective doses of the most frequent CT examinations].

    Science.gov (United States)

    Homolka, Peter; Leithner, Robert; Billinger, Jochen; Gruber, Michael

    2014-09-01

    To determine typical doses from common CT examinations of standard sized adult patients and their variability between CT operators for common CT indications. In a nationwide Austrian CT dose survey doses from approx. 10,000 common CT examinations of adults during 2009 and 2010 were collected and "typical" radiation doses to the "average patient", which turned out to have 75.6kg body mass, calculated. Conversion coefficients from DLP to effective dose were determined and effective doses calculated according to ICRP 103. Variations of typically applied doses to the "average patient" were expressed as ratios between 90(th) and 10(th) percentile (inter-percentile width, IPW90/10), 1(st) and 3(rd) quartile (IPW75/25), and Maximum/Minimum. Median effective doses to the average patients for standard head and neck scans were 1.8 mSv (cervical spine), 1.9 mSv (brain: trauma/bleeding, stroke) to 2.2 mSv (brain: masses) with typical variation between facilities of a factor 2.5 (IPW90/10) and 1.7 (IPW75/25). In the thorax region doses were 6.4 to 6.8 mSv (pulmonary embolism, pneumonia and inflammation, oncologic scans), the variation between facilities was by a factor of 2.1 (IPW90/10) and 1.5 (IPW75/25), respectively. In the abdominal region median effective doses from 6.5 mSv (kidney stone search) to 22 mSv (liver lesions) were found (acute abdomen, staging/metastases, lumbar spine: 9-12 mSv; oncologic abdomen plus chest 16 mSv; renal tumor 20 mSv). Variation factors between facilities were on average for abdominal scans 2.7 (IPW90/10) and 1.8 (IPW75/25). Variations between CT operators are generally moderate for most operators, but in some indications the ratio between the minimum and the maximum of average dose to the typical standard patients exceeds a factor of 4 or even 5. Therefore, comparing average doses to Diagnostic Reference Levels (DRLs) and optimizing protocols need to be encouraged. Copyright © 2014. Published by Elsevier GmbH.

  11. Value of non-contrast CT examination of the urinary tract (stone ...

    African Journals Online (AJOL)

    Mohamed Samir Shaaban

    2015-09-04

    Sep 4, 2015 ... Abstract Background: Urolithiasis is one of the most common urinary tract diseases worldwide, with a wide range of affected age groups. Non-contrast CT examination of the urinary tract is the gold-standard examination for detection and characterization of urinary tract stones, with great impact upon the ...

  12. Value of non-contrast CT examination of the urinary tract (stone ...

    African Journals Online (AJOL)

    Background: Urolithiasis is one of the most common urinary tract diseases worldwide, with a wide range of affected age groups. Non-contrast CT examination of the urinary tract is the gold-standard examination for detection and characterization of urinary tract stones, with great impact upon the choice of method of ...

  13. The influence of CT control examinations on the irradiation planning for patients with cerebral metastases

    International Nuclear Information System (INIS)

    Haumann, S.

    1986-01-01

    The thesis is aimed at reviewing a therapy plan worked out previously for the treatment of patients with cerebral metastases, and at studying computerized tomography for its potential benefit in the planning and implementation of radiotherapy. 61 patients were irradiated and examined neurologically and by CT before, during and after treatment, thus allowing a thorough-going analysis of the findings. CT evaluations differentiated between the change of volume and the number of metastases as well as the change of the extension of perifocal oedema. Our experience shows a dose of 30 Gy related to the centre of the skull to be sufficient, on the one hand, in order to determine by CT whether or not the existing intracerebral tumour metastases of the patient concerned will be accessible by radiotherapy at all, and, on the other hand, to destroy metastases smaller than 5 mm which cannot be detected by CT. (orig./MG) [de

  14. Significance of pelvic CT examination for the diagnosis of the distal colonic and rectal cancer

    International Nuclear Information System (INIS)

    Shindo, Takeshi

    1984-01-01

    Pelvic CT examination was performed in preoperative 40 patients and postoperrative 51 patients of the distal colonic and rectal carcinoma. CT study expect for the decision of the depth of invasion and the detection of lymphnode metastasis, or the location of recurrence. Diagnostic accuracy rate of the depth of invasion was 68.6% in tumors of sigmoid colon, rectosigmoid, and upper rectum, and 78.9% in lower rectum, and anal canal. These rate were superior to those of selective angiographic examination. Diagnostic accuracy rate for lymphnode metastasis was 73.0%. CT examination could define the lymphnode swelling, but could not define if those were metastasis or not. Furthermore, CT-angiography was beneficial for the estimation of the depth of invasion. The differentiation between local recurrent tumor and granulomatous mass in the perineum after abdomino-perineal resection is the most important problem, however, the further studies are necessary to obtain the definite criteria of differential diagnosis. Above results support that CT examination should be used routinely in the distal colonic and rectal cancer patients. (author)

  15. Consideration of the usefulness of a size-specific dose estimate in pediatric CT examination.

    Science.gov (United States)

    Tsujiguchi, Takakiyo; Obara, Hideki; Ono, Shuichi; Saito, Yoko; Kashiwakura, Ikuo

    2018-04-05

    Computed tomography (CT) has recently been utilized in various medical settings, and technological advances have resulted in its widespread use. However, medical radiation exposure associated with CT scans accounts for the largest share of examinations using radiation; thus, it is important to understand the organ dose and effective dose in detail. The CT dose index and dose-length product are used to evaluate the organ dose. However, evaluations using these indicators fail to consider the age and body type of patients. In this study, we evaluated the effective dose based on the CT examination data of 753 patients examined at our hospital using the size-specific dose estimate (SSDE) method, which can calculate the exposure dose with consideration of the physique of a patient. The results showed a large correlation between the SSDE conversion factor and physique, with a larger exposure dose in patients with a small physique when a single scan is considered. Especially for children, the SSDE conversion factor was found to be 2 or more. In addition, the patient exposed to the largest dose in this study was a 10-year-old, who received 40.4 mSv (five series/examination). In the future, for estimating exposure using the SSDE method and in cohort studies, the diagnostic reference level of SSDE should be determined and a low-exposure imaging protocol should be developed to predict the risk of CT exposure and to maintain the quality of diagnosis with better radiation protection of patients.

  16. U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations.

    Science.gov (United States)

    Kanal, Kalpana M; Butler, Priscilla F; Sengupta, Debapriya; Bhargavan-Chatfield, Mythreyi; Coombs, Laura P; Morin, Richard L

    2017-07-01

    Purpose To develop diagnostic reference levels (DRLs) and achievable doses (ADs) for the 10 most common adult computed tomographic (CT) examinations in the United States as a function of patient size by using the CT Dose Index Registry. Materials and Methods Data from the 10 most commonly performed adult CT head, neck, and body examinations from 583 facilities were analyzed. For head examinations, the lateral thickness was used as an indicator of patient size; for neck and body examinations, water-equivalent diameter was used. Data from 1 310 727 examinations (analyzed by using SAS 9.3) provided median values, as well as means and 25th and 75th (DRL) percentiles for volume CT dose index (CTDI vol ), dose-length product (DLP), and size-specific dose estimate (SSDE). Applicable results were compared with DRLs from eight countries. Results More than 46% of the facilities were community hospitals; 13% were academic facilities. More than 48% were in metropolitan areas, 39% were suburban, and 13% were rural. More than 50% of the facilities performed fewer than 500 examinations per month. The abdomen and pelvis was the most frequently performed examination in the study (45%). For body examinations, DRLs (75th percentile) and ADs (median) for CTDI vol , SSDE, and DLP increased consistently with the patient's size (water-equivalent diameter). The relationships between patient size and DRLs and ADs were not as strong for head and neck examinations. These results agree well with the data from other countries. Conclusion DRLs and ADs as a function of patient size were developed for the 10 most common adult CT examinations performed in the United States. © RSNA, 2017.

  17. Value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression

    Directory of Open Access Journals (Sweden)

    Ai-Jun Wu

    2016-12-01

    Full Text Available Objective: To study the value of preoperative enhanced multi-slice spiral CT scan for judging TNM staging of gastric cancer as well as its relationship with tumor marker and proliferation molecule expression. Methods: A total of 135 patients with gastric cancer who received surgical resection in our hospital between May 2012 and October 2015 were selected as the research subjects, preoperative enhanced multi-slice spiral CT scan was conducted to judge TNM staging, and serum was collected to determine the content of tumor markers; tumor tissue was collected after operation to determine the content of cytokines and pro-proliferation molecules. Results: CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM II, III and IV stage gastric cancer were significantly higher than those of patients with TNM I stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM III and IV stage gastric cancer were significantly higher than those of patients with TNM II stage; CEA, CA199, CA153, CA125 and CA724 content in serum as well as TGFβ1, TGFβ2, VEGF, FGF2, PTP1B, PIK3CD, Survivin, Ezrin and YAP content in gastric cancer tissue of patients with TNM IV stage gastric cancer were significantly higher than those of patients with TNM III stage. Conclusions: TNM staging of gastric cancer decided by preoperative enhanced multi-slice spiral CT scan has good consistency with the content of tumor markers in serum and proliferation molecules in tumor lesion.

  18. Development of age-specific Japanese physical phantoms for dose evaluation in infant CT examinations

    International Nuclear Information System (INIS)

    Yamauchi-Kawaura, C.; Fujii, K.; Imai, K.; Ikeda, M.; Akahane, K.; Obara, S.; Yamauchi, M.; Narai, K.; Katsu, T.

    2016-01-01

    Secondary to the previous development of age-specific Japanese head phantoms, the authors designed Japanese torso phantoms for dose assessment in infant computed tomography (CT) examinations and completed a Japanese 3-y-old head-torso phantom. For design of age-specific torso phantoms (0, 0.5, 1 and 3 y old), anatomical structures were measured from CT images of Japanese infant patients. From the CT morphometry, it was found that rib cages of Japanese infants were smaller than those in Europeans and Americans. Radiophotoluminescence glass dosemeters were used for dose measurement of a 3-y-old head-torso phantom. To examine the validity of the developed phantom, organ and effective doses by the in-phantom dosimetry system were compared with simulation values in a web-based CT dose calculation system (WAZA-ARI). The differences in doses between the two systems were <20 % at the doses of organs within scan regions and effective doses in head, chest and abdomino-pelvic CT examinations. (authors)

  19. DEVELOPMENT OF AGE-SPECIFIC JAPANESE PHYSICAL PHANTOMS FOR DOSE EVALUATION IN INFANT CT EXAMINATIONS.

    Science.gov (United States)

    Yamauchi-Kawaura, C; Fujii, K; Akahane, K; Yamauchi, M; Obara, S; Narai, K; Katsu, T; Imai, K; Ikeda, M

    2016-12-01

    Secondary to the previous development of age-specific Japanese head phantoms, the authors designed Japanese torso phantoms for dose assessment in infant computed tomography (CT) examinations and completed a Japanese 3-y-old head-torso phantom. For design of age-specific torso phantoms (0, 0.5, 1 and 3 y old), anatomical structures were measured from CT images of Japanese infant patients. From the CT morphometry, it was found that rib cages of Japanese infants were smaller than those in Europeans and Americans. Radiophotoluminescence glass dosemeters were used for dose measurement of a 3-y-old head-torso phantom. To examine the validity of the developed phantom, organ and effective doses by the in-phantom dosimetry system were compared with simulation values in a web-based CT dose calculation system (WAZA-ARI). The differences in doses between the two systems were doses of organs within scan regions and effective doses in head, chest and abdominopelvic CT examinations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Adult patient radiation doses from non-cardiac CT examinations: a review of published results

    Science.gov (United States)

    Pantos, I; Thalassinou, S; Argentos, S; Kelekis, N L; Panayiotakis, G; Efstathopoulos, E P

    2011-01-01

    Objectives CT is a valuable tool in diagnostic radiology but it is also associated with higher patient radiation doses compared with planar radiography. The aim of this article is to review patient dose for the most common types of CT examinations reported during the past 19 years. Methods Reported dosimetric quantities were compared with the European diagnostic reference levels (DRLs). Effective doses were assessed with respect to the publication year and scanner technology (i.e. single-slice vs multislice). Results Considerable variation of reported values among studies was attributed to variations in both examination protocol and scanner design. Median weighted CT dose index (CTDIw) and dose length product (DLP) are below the proposed DRLs; however, for individual studies the DRLs are exceeded. Median reported effective doses for the most frequent CT examinations were: head, 1.9 mSv (0.3–8.2 mSv); chest, 7.5 mSv (0.3–26.0 mSv); abdomen, 7.9 mSv (1.4–31.2 mSv); and pelvis, 7.6 mSv (2.5–36.5 mSv). Conclusion The introduction of mechanisms for dose reduction resulted in significantly lower patient effective doses for CT examinations of the head, chest and abdomen reported by studies published after 1995. Owing to the limited number of studies reporting patient doses for multislice CT examinations the statistical power to detect differences with single-slice scanners is not yet adequate. PMID:21266399

  1. Evaluation of the radiation doses in newborn patients submitted to CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    De Souza Santos, William; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear (IPENCNEN/SP), Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, 05508-000 Sao Paulo, SP, (Brazil); Belinato, Walmir [Departamento de Ensino, Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia, Campus Vitoria da Conquista, Zabele, Av. Amazonas 3150, 45030-220 Vitoria da Conquista, BA, (Brazil); Pereira Neves, Lucio; Perini, Ana Paula [Instituto de Fisica, Universidade Federal de Uberlandia, Caixa Postal 593, 38400-902, Uberlandia, MG, (Brazil)

    2015-07-01

    The number of computed tomography (CT) scans available to the population is increasing, as well as the complexity of such exams. As a result, the radiation doses are increasing as well. Considering the population exposed to CT exams, pediatric patients are considerably more sensitive to radiation than adults. They have a longer life expectancy than adults, and may receive a higher radiation dose than necessary if the CT scan settings are not adjusted for their smaller body size. As a result of these considerations, the risk of developing cancer is of great concern when newborn patients are involved. The objective of this work was to study the radiation doses on radiosensitive organs of newborn patients undergoing a whole body CT examination, utilizing Monte Carlo simulations. The novelty of this work is the use of pediatric virtual anthropomorphic phantoms, developed at the Department of Nuclear Energy at the Federal University of Pernambuco (DEN/UFPE). The CT equipment utilized during the simulations was a Discovery VCT GE PET/CT system, with a tube voltage of 140 kVp. The X-ray spectrum of this CT scanner was generated by the SRS-78 software, which takes into account the X-ray beam energy used in PET/CT procedures. The absorbed organ doses were computed employing the F6 tally (MeV/g). The results were converted to dose coefficients (mGy/100 mA) for all the structures, considering all employed beams. The highest dose coefficients values were obtained for the brain and the thyroid. This work provides useful information regarding the risks involving ionizing radiation in newborn patients, employing a new and reliable technique. (authors)

  2. Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination

    International Nuclear Information System (INIS)

    McKnight, Colin D.; Watcharotone, Kuanwong; Ibrahim, Mohannad; Christodoulou, Emmanuel; Baer, Aaron H.; Parmar, Hemant A.

    2014-01-01

    Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited. The objective of our study was to retrospectively compare the image quality and radiation dose of pediatric head CT examinations obtained with ASIR compared to pediatric head CT examinations without ASIR in a large patient population. Retrospective analysis was performed on 82 pediatric head CT examinations. This group included 33 pediatric head CT examinations obtained with ASIR and 49 pediatric head CT examinations without ASIR. Computed tomography dose index (CTDI vol ) was recorded on all examinations. Quantitative analysis consisted of standardized measurement of attenuation and the standard deviation at the bilateral centrum semiovale and cerebellar white matter to evaluate objective noise. Qualitative analysis consisted of independent assessment by two radiologists in a blinded manner of gray-white differentiation, sharpness and overall diagnostic quality. The average CTDI vol value of the ASIR group was 21.8 mGy (SD = 4.0) while the average CTDI vol for the non-ASIR group was 29.7 mGy (SD = 13.8), reflecting a statistically significant reduction in CTDI vol in the ASIR group (P 12-year-old ASIR group as compared to the >12-year-old non-ASIR group (29.7 mGy vs. 49.9 mGy; P = 0.0002). Quantitative analysis revealed no significant difference in the homogeneity of variance in the ASIR group compared to the non-ASIR group. Radiologist assessment of gray-white differentiation, sharpness and overall diagnostic quality in ASIR examinations was not substantially different compared to non-ASIR examinations. The use of ASIR in

  3. Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Colin D.; Watcharotone, Kuanwong; Ibrahim, Mohannad; Christodoulou, Emmanuel; Baer, Aaron H.; Parmar, Hemant A. [University of Michigan, Department of Radiology, Ann Arbor, MI (United States)

    2014-08-15

    Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited. The objective of our study was to retrospectively compare the image quality and radiation dose of pediatric head CT examinations obtained with ASIR compared to pediatric head CT examinations without ASIR in a large patient population. Retrospective analysis was performed on 82 pediatric head CT examinations. This group included 33 pediatric head CT examinations obtained with ASIR and 49 pediatric head CT examinations without ASIR. Computed tomography dose index (CTDI{sub vol}) was recorded on all examinations. Quantitative analysis consisted of standardized measurement of attenuation and the standard deviation at the bilateral centrum semiovale and cerebellar white matter to evaluate objective noise. Qualitative analysis consisted of independent assessment by two radiologists in a blinded manner of gray-white differentiation, sharpness and overall diagnostic quality. The average CTDI{sub vol} value of the ASIR group was 21.8 mGy (SD = 4.0) while the average CTDI{sub vol} for the non-ASIR group was 29.7 mGy (SD = 13.8), reflecting a statistically significant reduction in CTDI{sub vol} in the ASIR group (P < 0.01). There were statistically significant reductions in CTDI for the 3- to 12-year-old ASIR group as compared to the 3- to 12-year-old non-ASIR group (21.5 mGy vs. 30.0 mGy; P = 0.004) as well as statistically significant reductions in CTDI for the >12-year-old ASIR group as compared to the >12-year-old non-ASIR group (29.7 mGy vs. 49.9 mGy; P = 0.0002). Quantitative analysis revealed no significant difference in the

  4. CT coronary angiography: examination technique, clinical results, and outlook on future developments

    International Nuclear Information System (INIS)

    Dewey, M.; Hamm, B.

    2007-01-01

    Multislice computed tomography (MSCT) after intravenous contrast agent administration enables visualization of the coronary arteries with high spatial resolution (voxel sizes down to 0.5 x 0.35 x 0.35 mm3) and a short scan time. Magnetic resonance imaging (MRI) is also intensively studied with respect to the noninvasive detection of coronary artery stenosis and thus the detection of coronary artery disease (CAD) without radiation exposure but is not equal to MSCT at present. This article provides an overview of the historical development of CT coronary angiography from 4-slice CT to 16-slice CT and 64-slice CT. A crucial aspect of this development is the improvement in image quality resulting from shorter breath-hold periods and the reduced gantry rotation time. Other techniques that appear to considerably improve image quality and accuracy and make CT independent of patient heart rates are multisegment reconstruction and dual-source CT. Sublingual nitroglycerin as well as oral or intravenous betablocker administration should be considered in relation to the diagnostic question to be answered and the patient's heart rate. In the studies available CT coronary angiography with at least 12 simultaneous detector rows has a sensitivity of 96.9 % and a specificity of 75.3 % at the patient level. Especially the negative predictive value of CT (94.6 %) emphasizes the idea that this technique may reliably exclude CAD in patients with intermediate pretest likelihood. In the near future, 256-slice CT will allow examination of the entire heart during one heartbeat or even 4D CT scanning with simultaneous assessment of myocardial perfusion. Automatic or semiautomatic software tools will assume a central place in detecting and quantifying coronary artery stenoses and plaques as well as in the analysis of cardiac function in the clinical setting over the next years. Prior to its routine clinical use, the cost-effectiveness of CT coronary angiography must be determined and the

  5. Evaluation of radiation dose in pediatric head CT examination: a phantom study

    Science.gov (United States)

    Norhasrina Nik Din, Nik; Zainon, Rafidah; Rahman, Ahmad Taufek Abdul

    2018-01-01

    The aim of this study was to evaluate the radiation dose in pediatric head Computed Tomography examination. It was reported that decreasing tube voltage in CT examination can reduce the dose to patients significantly. A head phantom was scanned with dual-energy CT at 80 kV and 120 kV. The tube current was set using automatic exposure control mode and manual setting. The pitch was adjusted to 1.4, 1.45 and 1.5 while the slice thickness was set at 5 mm. The dose was measured based on CT Dose Index (CTDI). Results from this study have shown that the image noise increases substantially with low tube voltage. The average dose was 2.60 mGy at CT imaging parameters of 80 kV and 10 - 30 mAs. The dose increases up to 17.19 mGy when the CT tube voltage increases to 120 kV. With the reduction of tube voltage from 120 kV to 80 kV, the radiation dose can be reduced by 12.1% to 15.1% without degradation of contrast-to-noise ratio.

  6. An investigation into CT radiation dose variations for head examinations on matched equipment

    International Nuclear Information System (INIS)

    Zarb, Francis; Foley, Shane; Toomey, Rachel; Rainford, Louise; Holm, Susanne; Evanoff, Michael G.

    2016-01-01

    This study investigated radiation dose and image quality differences for computed tomography (CT) head examinations across centres with matched CT equipment. Radiation dose records and imaging protocols currently employed across three European university teaching hospitals were collated, compared and coded as Centres A, B and C from specification matched CT equipment models. Patient scans (n = 40) obtained from Centres A and C were evaluated for image quality, based on the visualisation of Commission of European Community (CEC) image quality criteria using visual grading characteristic (VGC) analysis, where American Board of Radiology examiners (n = 11) stated their confidence in identifying anatomical criteria. Mean doses in terms of CT dose index (CTDI vol -mGy) and dose length product (DLP-mGy cm) were as follows: Centre A-33.12 mGy and 461.45 mGy cm; Centre B -101 mGy (base)/32 mGy (cerebrum) and 762 mGy cm and Centre C-71.98 mGy and 1047.26 mGy cm, showing a significant difference (p ≤ 0.05) in DLP across centres. VGC analysis indicated better visualisation of CEC criteria on Centre C images (VGC AUC 0.225). All three imaging protocols are routinely used clinically, and image quality is acceptable in each centre. Clinical centres with identical model CT scanners have variously customised their protocols achieving a range of dose savings and still resulting in clinically acceptable image quality. (authors)

  7. Evaluation of the effective dose of cone beam CT and multislice CT for temporomandibular joint examinations at optimized exposure levels.

    Science.gov (United States)

    Kadesjö, N; Benchimol, D; Falahat, B; Näsström, K; Shi, X-Q

    2015-01-01

    To compare the effective dose to patients from temporomandibular joint examinations using a dental CBCT device and a multislice CT (MSCT) device, both before and after dose optimization. A Promax(®) 3D (Planmeca, Helsinki, Finland) dental CBCT and a LightSpeed VCT(®) (GE Healthcare, Little Chalfont, UK) multislice CT were used. Organ doses and effective doses were estimated from thermoluminescent dosemeters at 61 positions inside an anthropomorphic phantom at the exposure settings in clinical use. Optimized exposure protocols were obtained through an optimization study using a dry skull phantom, where four observers rated image quality taken at different exposure levels. The optimal exposure level was obtained when all included criteria were rated as acceptable or better by all observers. The effective dose from a bilateral examination was 184 µSv for Promax 3D and 113 µSv for LightSpeed VCT before optimization. Post optimization, the bilateral effective dose was 92 µSv for Promax 3D and 124 µSv for LightSpeed VCT. At optimized exposure levels, the effective dose from CBCT was comparable to MSCT.

  8. Discrete Event Simulation Models for CT Examination Queuing in West China Hospital

    Science.gov (United States)

    Luo, Li; Tang, Shijun; Shi, Yingkang; Guo, Huili

    2016-01-01

    In CT examination, the emergency patients (EPs) have highest priorities in the queuing system and thus the general patients (GPs) have to wait for a long time. This leads to a low degree of satisfaction of the whole patients. The aim of this study is to improve the patients' satisfaction by designing new queuing strategies for CT examination. We divide the EPs into urgent type and emergency type and then design two queuing strategies: one is that the urgent patients (UPs) wedge into the GPs' queue with fixed interval (fixed priority model) and the other is that the patients have dynamic priorities for queuing (dynamic priority model). Based on the data from Radiology Information Database (RID) of West China Hospital (WCH), we develop some discrete event simulation models for CT examination according to the designed strategies. We compare the performance of different strategies on the basis of the simulation results. The strategy that patients have dynamic priorities for queuing makes the waiting time of GPs decrease by 13 minutes and the degree of satisfaction increase by 40.6%. We design a more reasonable CT examination queuing strategy to decrease patients' waiting time and increase their satisfaction degrees. PMID:27547237

  9. CT examination after intrathecal or intraventricular application of metrizamide in 110 patients for neurosurgery

    International Nuclear Information System (INIS)

    Krakow, D.

    1983-01-01

    The CT scans were done in 110 patients for examination of the liquor carrying cerebral brain compartments, especially the cisterns, after intrathecal application of the radiopaque medium metrizamide. The properties of the medium are explained in detail. (orig./MG) [de

  10. The influence of population aging and size on the number of CT examinations in the Netherlands

    NARCIS (Netherlands)

    Ischa de Waard-Schalkx; Mathieu Pruppers; Harmen Bijwaard

    2014-01-01

    Exposures to ionizing radiation frommedical examinations are on the rise. An important cause for this has been the advent and ever-increasing use of computed tomography (CT) scans for diagnostic purposes. It is often implied that population aging contributes significantly to this rise. Here, the

  11. The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers; Tomografia Computerizzata spirale con elaborazioni tridimensionali di superficie nel trattamento ricostruttivo dei tumori maligni del massiccio facciale

    Energy Technology Data Exchange (ETDEWEB)

    De Rosa, V.; Ziviello, M. [Ospedale Cardarelli, Servizio di Radiodiagnostica, Naples (Italy); Ionna, F.; Mozzillo, N. [Ospedale Cardarelli, Div. di Chirurgia B, Ist. Nazionale Tumori Fondazione G. Pascale, Naples (Italy); Parascandolo, S. [Ospedale Cardarelli, Div. di Chirurgia Maxillo-Facciale, Naples (Italy)

    2000-12-01

    Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micronets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed CT images were obtained preoperatively and at least 6 months postoperatively in all patients. The images were generated on a computer workstation using the shaded surface display (SSD) software with threshold values ranging 425 to 630 HU, and a more closed window for the imaging of titanium mesh/bone interface in the post surgical follow-up. It was obtained an excellent complete spatial depiction of maxillo facial region both before and after surgery, with no artefacts so important as to affect the 3D reconstruction process and the image quality. Together with the head-neck surgical team it could be worked for preoperative planning through CT scans by different 3D points of view. The 3D reconstructed follow-up scans showed good filling of the defect in the area where the titanium mesh had been used. Then efficacious bone modelling and good biocompatibility of the alloplastic material were seen in all patients, with no inflammatory reactions. Titanium is a well-known material, which is widely used for cranioplasty. It is a radiolucent, non

  12. Comparative evaluation of organ and effective doses for paediatric patients with those for adults in chest and abdominal CT examinations.

    Science.gov (United States)

    Fujii, K; Aoyama, T; Koyama, S; Kawaura, C

    2007-08-01

    Patient doses in paediatric and adult CT examinations were investigated for modern multislice CT scanners by using specially constructed in-phantom dose measuring systems. The systems were composed of 32 photodiode dosemeters embedded in various tissue and organ sites within anthropomorphic phantoms representing the bodies of 6-year-old children and adults. Organ and the effective doses were evaluated from dose values measured at these sites. In chest CT examinations, organ doses for organs within the scanning area were 2-21 mGy for children and 7-26 mGy for adults. Thyroid doses for children were frequently the highest with a maximum of 21 mGy. In abdominal CT examinations, organ doses for organs within the scanning area were 3-16 mGy for children and 10-34 mGy for adults. Effective doses evaluated for children and adults were found to be proportional to the effective mAs of CT scanners, where linear coefficients were specific to the types of CT examinations and to the manufacturers of CT scanners. Effective doses in paediatric chest CT and abdominal CT examinations were lower than those in adult examinations by a factor of two or greater on average for the same CT scanners because of the lower effective mAs adopted in paediatric examinations.

  13. Effective and equivalent doses for CT head examinations calculated using the voxelized phantoms MASH and FASH

    Science.gov (United States)

    Ferreira, C. C.; Folly, W. S. D.; Vieira, J. W.; Maia, A. F.

    2011-09-01

    The voxelized phantoms MASH and FASH have been used for calculating conversion coefficients (CCs) for a specific CT head examination performed in a specific Toshiba CT scanner. The X-ray spectrum was selected according to the concordance between the calculated C 100,c and measured C 100,c. For 120 kV, the X-raytbc code presented the smaller deviation, equal to -7.11%. Finally, effective doses calculated for the voxelized phantoms MASH and FASH were 6.1 and 4.5, respectively, smaller than the effective dose obtained though the European guidelines on quality criteria for computed tomography.

  14. Geometric studies on variable radius spiral cone-beam scanning

    International Nuclear Information System (INIS)

    Ye Yangbo; Zhu Jiehua; Wang Ge

    2004-01-01

    The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and uniqueness of PI lines inside the variable radius 3D spiral. These results are necessary steps toward exact cone-beam reconstruction from a 3D spiral scan of variable radius, adapting Katsevich's formula for the standard helical cone-beam scanning. It is shown in the paper that when the longitudinally projected planar spiral is not always convex toward the origin, the PI line may not be unique in the envelope defined by the tangents of the spiral. This situation can be avoided by using planar spirals whose curvatures are always positive. Using such a spiral, a longitudinally homogeneous region inside the corresponding 3D spiral is constructed in which any point is passed by one and only one PI line, provided the angle ω between planar spiral's tangent and radius is bounded by vertical bar ω-90 deg. vertical bar ≤ε for some positive ε≤32.48 deg. If the radius varies monotonically, this region is larger and one may allow ε≤51.85 deg. Examples for 3D spirals based on logarithmic and Archimedean spirals are given. The corresponding generalized Tam-Danielsson detection windows are also formulated

  15. Clinical implications of eye deviation on admission CT examination of acute ischaemic stroke patients.

    Science.gov (United States)

    Payabvash, S; Qureshi, I; Qureshi, A I

    2016-12-01

    To determine the frequency and prognostic value of eye deviation detected on the admission computed tomography (CT) of acute ischaemic stroke patients. The clinical and imaging data from the Albumin in Acute Stroke (ALIAS) Trials 1 and 2 were analysed. Two reviewers evaluated all admission CT images for the presence of eye deviation, and Alberta Stroke Program Early CT Score (ASPECTS). The admission National Institutes of Health Stroke Scale (NIHSS) scores and 3-month modified Rankin scale (mRs) scores were ascertained. Disability or death was defined as mRS score >2, at 3-month follow-up. Of 1,223 patients included in the present series, 352 (28.8%) had rightward and 331 (27.1%) had leftward eye deviation on admission CT. Patients with eye deviation on CT had higher admission NIHSS score and larger middle cerebral artery (MCA) territory infarct volume (based on ASPECTS). The presence of eye deviation on CT was associated with higher rates of haemorrhagic transformation at 24 hours (19.8% versus 13.5%, p=0.004), and higher rates of disability or death at 3-month follow-up (53.1% versus 35.7%, pMediation analysis showed that radiological eye deviation relation with higher rate of disability or death is predominantly due to its association with higher admission NIHSS scores, lower ASPECTS, and to a lesser extent patients' older age. The presence of eye deviation on CT examination of acute ischaemic stroke patients is associated with larger anterior circulation stroke volumes, higher risk of 24-hour haemorrhagic transformation, and 3-month disability or death. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations.

    Science.gov (United States)

    Tzedakis, Antonis; Damilakis, John; Perisinakis, Kostas; Karantanas, Apostolos; Karabekios, Spiros; Gourtsoyiannis, Nicholas

    2007-04-01

    The purpose of this study was to evaluate the effect of z overscanning on normalized effective dose for pediatric patients undergoing multidetector-computed tomography (CT) examinations. Five commercially available mathematical anthropomorphic phantoms representing newborn, 1-, 5-, 10-, and 15-year-old patients and the Monte Carlo N-Particle (MCNP, version 4C2) radiation transport code were employed in the current study to simulate pediatric CT exposures. For all phantoms, axial and helical examinations at 120 kV tube voltage were simulated. Scans performed at 80 kV were also simulated. Sex-specific normalized effective doses were estimated for four standard CT examinations i.e., head-neck, chest, abdomen-pelvis, and trunk, for all pediatric phantoms. Data for both axial and helical mode acquisition were obtained. In the helical mode, z overscanning was taken into account. The validity of the Monte Carlo results was verified by comparison with dose data obtained using thermoluminescence dosimetry and a physical pediatric anthropomorphic phantom simulating a 10-year-old child. In all cases normalized effective dose values were found to increase with increasing z overscanning. The percentage differences in normalized data between axial and helical scans may reach 43%, 70%, 36%, and 26% for head-neck, chest, abdomen-pelvis, and trunk studies, respectively. Normalized data for female pediatric patients was in general higher compared to male patients for all ages, examined regions, and z overscanning values. For both male and female children, the normalized effective dose values were reduced as the age was increased. For the same typical exposure conditions, dose values decreased when lower tube voltage was used; for a 1-year-old child, for example, the effective dose was 3.8 times lower when 80 kV instead of 120 kV was used. Normalized data for the estimation of effective dose to pediatric patients undergoing standard axial and helical CT examinations on an

  17. Patient doses in CT examinations in 18 countries: initial results from International Atomic Energy Agency projects.

    Science.gov (United States)

    Muhogora, W E; Ahmed, N A; Beganovic, A; Benider, A; Ciraj-Bjelac, O; Gershan, V; Gershkevitsh, E; Grupetta, E; Kharita, M H; Manatrakul, N; Milakovic, M; Ohno, K; Ben Omrane, L; Ptacek, J; Schandorf, C; Shabaan, M S; Stoyanov, D; Toutaoui, N; Wambani, J S; Rehani, M M

    2009-09-01

    The purpose of this prospective study at 73 facilities in 18 countries in Africa, Asia and Eastern Europe was to investigate if the CT doses to adult patients in developing countries are higher than international standards. The dose assessment was performed in terms of weighted computed tomography dose index (CTDIw) and dose length product (DLP) for chest, chest (high resolution), lumbar spine, abdomen and pelvis CT examinations using standard methods. Except in one case, the mean CTDIw values were below diagnostic reference level (DRL) while for DLP, 17 % of situations were above DRLs. The resulting CT images were of adequate quality for diagnosis. The CTDIw and DLP data presented herein are largely similar to those from two recent national surveys. The study has shown a stronger need to create awareness and training of radiology personnel as well as monitoring of radiation doses in many developing countries so as to conform to the ALARA principle.

  18. Patient doses in CT examinations in Switzerland: Implementation of national diagnostic reference levels

    International Nuclear Information System (INIS)

    Treier, R.; Aroua, A.; Verdun, F. R.; Samara, E.; Stuessi, A.; Trueb, P. R.

    2010-01-01

    Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland. (authors)

  19. Contrast-enhanced helical CT in sigmoid diverticulitis. Findings and impact on diagnosis and treatment; Ruolo della tomografia computerizzata spirale nella diverticolite del sigma e implicazioni diagnostico-terapeutiche

    Energy Technology Data Exchange (ETDEWEB)

    Scaglione, M.; Romano, L.; Pinto, A.; De Lutio di Castelguidone, E.; Giovine, S.; Pinto, F. [Azienda Ospedaliera di Rilievo Nazionale A. Cardarelli, Naples (Italy). Dipt. di Diagnostica per Immagini; Forner, A.L. [Azienda Ospedaliera di Rilievo Nazionale A. Cardarelli, Naples (Italy). Dipt. di Chirurgia d' Urgenza; Grassi, R. [Naples Univ. II, Naples (Italy). Ist. di Radiologia

    2000-03-01

    Aim of this retrospective study was to assess the capability of contrast-enhanced helical computerised tomography (CT) in sigmoid diverticulitis, especially relative to selection of the appropriate treatment. The findings of 41 patients were reviewed from 1998 to 1999 June. Contrast-enhanced helical CT is the imaging modality of choice in assessing mild or severe acute diverticulitis because it provides useful information for appropriate treatment planning in the emergency setting. This technique is most useful in questionable cases and in patients with suspected severe diverticulitis where a choice must be made between different treatment options. [Italian] Scopo di questo studio retrospettivo e' illustrare i molteplici aspetti radiologici della flogosi diverticolare sigmoidea con tomografia computerizzata (TC) spirale, con specifico riguardo alle implicazioni terapeutiche che scaturiscono dall'analisi e dal confronto dei reperti TC con i riscontri clinici e chirurgici. Sono analizzati e discussi i risultati dello studio di 41 pazienti consecutivi con diverticolite del sigma esaminati dal giugno del 1998 al giugno del 1999. La TC spirale ha fornito dettagli precisi sul danno anatomo-chirurgico dell'ansa e sulle strutture limitrofe coinvolte consentendo di differenziare la diverticolite lieve da quella grave. Il suo ruolo si configura nei pazienti critici difficilmente classificabili e nelle sospette diverticoliti gravi o complicate per la molteplicita' delle scelte terapeutiche.

  20. Frequency and topography of lesions of the femoro-tibial cartilage at spiral CT arthrography of the knee: a study in patients with normal knee radiographs and without history of trauma

    International Nuclear Information System (INIS)

    Vande Berg, B.C.; Lecouvet, F.E.; Malghem, J.

    2002-01-01

    To determine the frequency and topography of cartilage lesions involving the femoro-tibial joints in patients with normal knee radiographs and without a remembered history of trauma.Design and patients. A radiologist retrospectively reviewed the dual-detector spiral CT knee arthrograms performed in 209 consecutive patients (mean age 37.6 years) with normal knee radiographs. Images were analyzed for the presence, grade (Noyes classification system) and location of cartilage lesions, the location being designated by dividing each articular surface into a grid of 16 parts.Results. Fifty-three percent of knees had cartilage lesions of grade 2A or higher that involved articular surfaces to a variable extent: lateral tibial plateau (31%), medial femoral condyle (27%), medial tibial plateau (14%) and lateral femoral condyle (5%). Areas of the posterior half of the lateral tibial plateau and of the inner half of the medial femoral condyle were statistically more frequently involved than their counterparts (P<0.0001). The bare area of the medial tibial plateau, but not that of the lateral tibial plateau, was more frequently involved than the corresponding meniscus-covered area (P<0.0001).Conclusion. Cartilage lesions of grade 2A or higher, detected at spiral CT arthrography in 53% of the knees, predominantly involved the posterior half of the lateral tibial plateau, the inner half of the medial femoral condyle and the bare area of the medial tibial plateau. (orig.)

  1. Thyroid doses and risk to paediatric patients undergoing neck CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Spampinato, Maria Vittoria; Tipnis, Sameer; Huda, Walter [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Tavernier, Joshua [Medical University of South Carolina, College of Medicine, Charleston, SC (United States)

    2015-07-15

    To estimate thyroid doses and cancer risk for paediatric patients undergoing neck computed tomography (CT). We used average CTDI{sub vol} (mGy) values from 75 paediatric neck CT examinations to estimate thyroid dose in a mathematical anthropomorphic phantom (ImPACT Patient CT Dosimetry Calculator). Patient dose was estimated by modelling the neck as mass equivalent water cylinder. A patient size correction factor was obtained using published relative dose data as a function of water cylinder size. Additional correction factors included scan length and radiation intensity variation secondary to tube-current modulation. The mean water cylinder diameter that modelled the neck was 14 ± 3.5 cm. The mathematical anthropomorphic phantom has a 16.5-cm neck, and for a constant CT exposure, would have thyroid doses that are 13-17 % lower than the average paediatric patient. CTDI{sub vol} was independent of age and sex. The average thyroid doses were 31 ± 18 mGy (males) and 34 ± 15 mGy (females). Thyroid cancer incidence risk was highest for infant females (0.2 %), lowest for teenage males (0.01 %). Estimated absorbed thyroid doses in paediatric neck CT did not significantly vary with age and gender. However, the corresponding thyroid cancer risk is determined by gender and age. (orig.)

  2. Thyroid doses and risk to paediatric patients undergoing neck CT examinations

    International Nuclear Information System (INIS)

    Spampinato, Maria Vittoria; Tipnis, Sameer; Huda, Walter; Tavernier, Joshua

    2015-01-01

    To estimate thyroid doses and cancer risk for paediatric patients undergoing neck computed tomography (CT). We used average CTDI vol (mGy) values from 75 paediatric neck CT examinations to estimate thyroid dose in a mathematical anthropomorphic phantom (ImPACT Patient CT Dosimetry Calculator). Patient dose was estimated by modelling the neck as mass equivalent water cylinder. A patient size correction factor was obtained using published relative dose data as a function of water cylinder size. Additional correction factors included scan length and radiation intensity variation secondary to tube-current modulation. The mean water cylinder diameter that modelled the neck was 14 ± 3.5 cm. The mathematical anthropomorphic phantom has a 16.5-cm neck, and for a constant CT exposure, would have thyroid doses that are 13-17 % lower than the average paediatric patient. CTDI vol was independent of age and sex. The average thyroid doses were 31 ± 18 mGy (males) and 34 ± 15 mGy (females). Thyroid cancer incidence risk was highest for infant females (0.2 %), lowest for teenage males (0.01 %). Estimated absorbed thyroid doses in paediatric neck CT did not significantly vary with age and gender. However, the corresponding thyroid cancer risk is determined by gender and age. (orig.)

  3. Indication-based diagnostic reference levels for adult CT-examinations in Finland.

    Science.gov (United States)

    Lajunen, A

    2015-07-01

    A diagnostic reference level (DRL) is a predefined dose level, which should not be exceeded in an examination that is conducted appropriately on an average-sized patient. Since dose from only one examination should not be compared with a DRL, the average dose from a good sample of at least 10 average-sized patients should be compared. The previous DRLs for computed tomography (CT)-examinations for adults in Finland were issued in 2007 and only covered examinations conducted on a particular body region. Because the image quality requirements, and thus the dose needed, vary between different indications, there has been a call for indication-based DRLs for CT. The new indication-based DRLs for CT came into effect on June 2013. They are based on a dose survey performed in 2012. Doses were collected from examinations conducted on a particular body region, based on some indication and from some special examination types. The DRLs were set according to the third quartile approach. On average, the DRLs for a particular body region dropped ∼ 20 % from the previous DRLs. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Development of a method to estimate organ doses for pediatric CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Papadakis, Antonios E., E-mail: apapadak@pagni.gr; Perisinakis, Kostas; Damilakis, John [Department of Medical Physics, University Hospital of Heraklion, Faculty of Medicine, University of Crete, P.O. Box 1352, Iraklion, Crete 71110 (Greece)

    2016-05-15

    Purpose: To develop a method for estimating doses to primarily exposed organs in pediatric CT by taking into account patient size and automatic tube current modulation (ATCM). Methods: A Monte Carlo CT dosimetry software package, which creates patient-specific voxelized phantoms, accurately simulates CT exposures, and generates dose images depicting the energy imparted on the exposed volume, was used. Routine head, thorax, and abdomen/pelvis CT examinations in 92 pediatric patients, ranging from 1-month to 14-yr-old (49 boys and 43 girls), were simulated on a 64-slice CT scanner. Two sets of simulations were performed in each patient using (i) a fixed tube current (FTC) value over the entire examination length and (ii) the ATCM profile extracted from the DICOM header of the reconstructed images. Normalized to CTDI{sub vol} organ dose was derived for all primary irradiated radiosensitive organs. Normalized dose data were correlated to patient’s water equivalent diameter using log-transformed linear regression analysis. Results: The maximum percent difference in normalized organ dose between FTC and ATCM acquisitions was 10% for eyes in head, 26% for thymus in thorax, and 76% for kidneys in abdomen/pelvis. In most of the organs, the correlation between dose and water equivalent diameter was significantly improved in ATCM compared to FTC acquisitions (P < 0.001). Conclusions: The proposed method employs size specific CTDI{sub vol}-normalized organ dose coefficients for ATCM-activated and FTC acquisitions in pediatric CT. These coefficients are substantially different between ATCM and FTC modes of operation and enable a more accurate assessment of patient-specific organ dose in the clinical setting.

  5. Evaluation of the usefulness of bismuth shields in PET/CT examination

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Lee, Ju Young; Kim, Ji Hyeon; Kung, Sik Nam; Lee, Tae Soo

    2014-01-01

    Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered

  6. Effective and organ doses from common CT examinations in one general hospital in Tehran, Iran

    Science.gov (United States)

    Khoramian, Daryoush; Hashemi, Bijan

    2017-09-01

    Purpose: It is well known that the main portion of artificial sources of ionizing radiation to human results from X-ray imaging techniques. However, reports carried out in various countries have indicated that most of their cumulative doses from artificial sources are due to CT examinations. Hence assessing doses resulted from CT examinations is highly recommended by national and international radiation protection agencies. The aim of this research has been to estimate the effective and organ doses in an average human according to 103 and 60 ICRP tissue weighting factor for six common protocols of Multi-Detector CT (MDCT) machine in a comprehensive training general hospital in Tehran/Iran. Methods: To calculate the patients' effective dose, the CT-Expo2.2 software was used. Organs/tissues and effective doses were determined for about 20 patients (totally 122 patients) for every one of six typical CT protocols of the head, neck, chest, abdomen-pelvis, pelvis and spine exams. In addition, the CT dosimetry index (CTDI) was measured in the standard 16 and 32 cm phantoms by using a calibrated pencil ionization chamber for the six protocols and by taking the average value of CT scan parameters used in the hospital compared with the CTDI values displayed on the console device of the machine. Results: The values of the effective dose based on the ICRP 103 tissue weighting factor were: 0.6, 2.0, 3.2, 4.2, 2.8, and 3.9 mSv and based on the ICRP 60 tissue weighting factor were: 0.9, 1.4, 3, 7.9, 4.8 and 5.1 mSv for the head, neck, chest, abdomen-pelvis, pelvis, spine CT exams respectively. Relative differences between those values were -22, 21, 23, -6, -31 and 16 percent for the head, neck, chest, abdomen-pelvis, pelvis, spine CT exams, respectively. The average value of CTDIv calculated for each protocol was: 27.32 ± 0.9, 18.08 ± 2.0, 7.36 ± 2.6, 8.84 ± 1.7, 9.13 ± 1.5, 10.42 ± 0.8 mGy for the head, neck, chest, abdomen-pelvis and spine CT exams, respectively

  7. How accurate is size-specific dose estimate in pediatric body CT examinations?

    Science.gov (United States)

    Karmazyn, Boaz; Ai, Huisi; Klahr, Paul; Ouyang, Fangqian; Jennings, S Gregory

    2016-08-01

    Size-specific dose estimate is gaining increased acceptance as the preferred index of CT dose in children. However it was developed based on non-clinical data. To compare the accuracy of size-specific dose estimate (SSDE) based on geometric and body weight measures in pediatric chest and abdomen CT scans, versus the more accurate [Formula: see text] (mean SSDE based on water-equivalent diameter). We retrospectively identified 50 consecutive children (age CT examination and 50 children who underwent abdomen CT. We measured anteroposterior diameter (DAP) and lateral diameter (DLAT) at the central slice (of scan length) of each patient and calculated DAP+LAT (anteroposterior diameter plus lateral diameter) and DED (effective diameter) for each patient. We calculated the following in each child: (1) SSDEs based on DAP, DLAT, DAP+LAT, DED, and body weight, and (2) SSDE based on software calculation of mean water-equivalent diameter ([Formula: see text] adopted standard within our study). We used intraclass correlation coefficient (ICC) and Bland-Altman analysis to compare agreement between the SSDEs and [Formula: see text]. Gender and age distribution were similar between chest and abdomen CT groups; mean body weight was 37 kg for both groups, with ranges of 6-130 kg (chest) and 8-107 kg (abdomen). SSDEs had very strong agreement (ICC>0.9) with [Formula: see text]. SSDEs based on DLAT had 95% limits of agreement of up to 43% with [Formula: see text]. SSDEs based on other parameters (body weight, DAP, DAP+LAT, DED) had 95% limits of agreement of up to 25%. Differences between SSDEs calculated using various indications of patient size (geometric indices and patient weight) and the more accurate [Formula: see text] calculated using proprietary software were generally small, with the possible exception for lateral diameter, and provide acceptable dose estimates for body CT in children.

  8. Dose reduction using bismuth shielding during paediatric CT examinations in Slovakia

    International Nuclear Information System (INIS)

    Gbelcova, L.; Nikodemova, D.; Horvathova, M.

    2011-01-01

    Considering the massive increase of computer tomography (CT) examinations in Slovakia during the last 10 y, it can be expected that a higher radiation load may be observed in the Slovak population. Since child population is more sensitive to radiation than adult population, a monitoring has started to see how high the radiation dose is for paediatric patients during CT examinations in chosen departments in Slovakia. The CT examination of the head is one of the most frequently done examinations in Slovakian departments and that is why measurements were done to clarify how usage of bismuth shields for eyes and thyroid can affect the eye and thyroid doses. For simulation, 215 thermoluminescent dosimeters were exposed on anthropomorphic phantom of a child with and without usage of bismuth shields. The result was that only two of the three chosen departments confirmed a reduction. On the other hand, one of the departments confirmed that the reduction can be up to 56-65 %, which is significant. (authors)

  9. EFFECTIVE DOSES RADIATION TO THE PATIENTS IN EXAMINATIONS PERFORMED IN THREE CT SCANNERS IN BRAZIL.

    Science.gov (United States)

    Ney, Mônica Silva Costa Janson; Dos Santos, Alair Augusto Sarmet Moreira Damas; Fonseca, GIuliana Vasconcelos De Souza; Lodi, Caio Silva

    2017-11-01

    This work aimed to analyze the effective doses radiation, estimated from the dose-length product, in 4821 examinations carried out in three CT scanners (named as A, B and C) during the period of December 1st 2013 to 30th November 2014 and compare them, with 95% confidence interval, with typical values for the CT practice described in the American Association of Physicists in Medicine (AAPM) Report # 96 (2008). The mean values of effective doses found in the A, B and C equipments were, respectively, 1.55, 2.09 and 1.30 mSv, in head; 7.75, 9.01 and 10.45 mSv in abdomen/pelvis; and 3.87, 7.94 and 3.92 mSv in chest examinations. There were significantly different among each service, except between the A and C equipments in the chest examinations (p = 0.7148). Only the B equipment performed CT scans with effective doses above the US typical values, for head and chest examinations. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    CERN Document Server

    Pavlicek, M

    2000-01-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time ...

  11. Evaluation of changes in vertebral body density following administration of contrast medium during routine CT examination

    International Nuclear Information System (INIS)

    Janicek, M.; Bruna, J.; Stenhova, H.

    1984-01-01

    The possibility is discussed of depicting changes in the density of spongiosis of the vertebral body in normal patients after intravenous administration of a bolus of 40 ml 60% Diazetrizoate in the course of a routine CT examination. The average increase in density immediately after the administration of the contrast medium is 12 H (8%), in the course of 10 minutes is reduced to 5 H (4%) against the initial values in native examination. These average changes are statistically significant, in individual patients, however, the increase in density following the administration of a contrast medium fluctuates considerably (from 0.7% to 10%). Only systematic comparison with various pathological conditions will make it possible to assess the possibilities of the evaluation of the structure of the vertebral body in routine CT with the administration of a contrast medium into the blood flow. (author)

  12. Axial CT of the brain compared with other clinical methods of examination in neuropaediatry

    International Nuclear Information System (INIS)

    Miller, E.

    1979-01-01

    CT of the neurocranium and EEC were carried out in 53 children aged 10 weeks to 15.5 years. In most of the children, also plain-film X-rays of the skull, echoencephalography, scintiscans of the brain, cerebral angiography and, in a few cases, pneumoencephalography were carried out. The methods of examination were comparatively evaluated for neoplastic, inflammatory, congenital and degenerative diseases and cerebral attacks. (APR) [de

  13. The efficacy of low-dose helical CT screening as an option for health examination

    International Nuclear Information System (INIS)

    Kishi, Kazuma; Hara, Shigeko; Kurosaki, Atsuko; Fujii, Takeshi; Yoshimura, Kunihiko

    2007-01-01

    We retrospectively evaluated the results of low-dose helical CT screening as an option for health examinations. From November 2002 to October 2005, CT screening was performed in 2,306 individuals (men 1,766, women 540, mean age 56.1 years). Among them, 71 individuals (3.1%) were diagnosed as having active thoracic diseases consisting of 14 neoplasms and 57 non-neoplastic diseases. Of 14 patients with neoplastic lesions, 13 had lung cancer, 1 of whom had double primary lung cancer, and 1 had atypical adenomatous hyperplasia. The mean diameter of the 14 lung cancers was 14.4 mm. The histology of these lesions was adenocarcinoma in 13 and squamous cell carcinoma in 1. The pathological stage was IA in 12 patients and IIA in 1. All patients underwent surgical resection. On the other hand, emphysema was diagnosed in 40 asymptomatic individuals based on CT and spirometry, and smoking cessation was strongly implemented for those who were current smokers. CT screening is useful for detecting not only early lung cancer but also non-neoplastic lung diseases. (author)

  14. Effective dose evaluation of multidetector CT examinations: influence of the ICRP recommendation in 2007.

    Science.gov (United States)

    Matsubara, Kosuke; Koshida, Kichiro; Suzuki, Masayuki; Shimono, Tetsunori; Yamamoto, Tomoyuki; Matsui, Osamu

    2009-12-01

    We compared effective doses for recent computed tomography (CT) examinations calculated based on International Commission on Radiological Protection publication number 103 (ICRP 103) with those calculated based on ICRP publication number 60 (ICRP 60), and considered the usefulness of the effective dose in CT dose evaluation. After placing radiophotoluminescence glass dosimeters (RPLDs) inside or outside an anthropomorphic phantom, we examined from the chest to the pelvis, cardiac, and cranial regions of the phantom. The absorbed dose was calculated by multiplying calibrated dose values of RPLD by the mass energy coefficient ratio. The effective dose was calculated as the sum total of the value for each tissue, which was multiplied by the equivalent dose according to the tissue weighting factor recommended in ICRP 103 and ICRP 60. Calculated effective doses based on ICRP 103 were different by –11% to +82% compared with those based on ICRP 60. The values of absorbed doses for selective tissues were relatively higher than the values for the effective dose. The effective dose represents only a mean dose value for an average human. Therefore, assessing the absolute dose of particular individuals in CT examinations based exclusively on the effective dose is not recommended.

  15. Spiral tectonics

    Science.gov (United States)

    Hassan Asadiyan, Mohammad

    2014-05-01

    Spiral Tectonics (ST) is a new window to global tectonics introduced as alternative model for Plate Tectonics (PT). ST based upon Dahw(rolling) and Tahw(spreading) dynamics. Analogues to electric and magnetic components in the electromagnetic theory we could consider Dahw and Tahw as components of geodynamics, when one component increases the other decreases and vice versa. They are changed to each other during geological history. D-component represents continental crust and T-component represents oceanic crust. D and T are two arm of spiral-cell. T-arm 180 degree lags behind D-arm so named Retard-arm with respect to D or Forward-arm. It seems primary cell injected several billions years ago from Earth's center therefore the Earth's core was built up first then mantel and finally the crust was build up. Crust building initiate from Arabia (Mecca). As the universe extended gravitation wave swirled the earth fractaly along cycloid path from big to small scale. In global scale (order-0) ST collect continents in one side and abandoned Pacific Ocean in the other side. Recent researches also show two mantels upwelling in opposite side of the Earth: one under Africa (tectonic pose) and the other under Pacific Ocean (tectonic tail). In higher order (order-1) ST build up Africa in one side and S.America in the other side therefore left Atlantic Ocean meandered in between. In order-n e.g. Khoor Musa and Bandar-Deylam bay are seen meandered easterly in the Iranian part but Khoor Abdullah and Kuwait bay meandered westerly in the Arabian part, they are distributed symmetrically with respect to axis of Persian Gulf(PG), these two are fractal components of easterly Caspian-wing and westerly Black Sea-wing which split up from Anatoly. Caspian Sea and Black Sea make two legs of Y-like structure, this shape completely fitted with GPS-velocity map which start from PG and split up in the Catastrophic Point(Anatoly). We could consider PG as remnants of Ancient Ocean which spent up

  16. Projected outcomes using different nodule sizes to define a positive CT lung cancer screening examination.

    Science.gov (United States)

    Gierada, David S; Pinsky, Paul; Nath, Hrudaya; Chiles, Caroline; Duan, Fenghai; Aberle, Denise R

    2014-11-01

    Computed tomography (CT) screening for lung cancer has been associated with a high frequency of false positive results because of the high prevalence of indeterminate but usually benign small pulmonary nodules. The acceptability of reducing false-positive rates and diagnostic evaluations by increasing the nodule size threshold for a positive screen depends on the projected balance between benefits and risks. We examined data from the National Lung Screening Trial (NLST) to estimate screening CT performance and outcomes for scans with nodules above the 4mm NLST threshold used to classify a CT screen as positive. Outcomes assessed included screening results, subsequent diagnostic tests performed, lung cancer histology and stage distribution, and lung cancer mortality. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated for the different nodule size thresholds. All statistical tests were two-sided. In 64% of positive screens (11598/18141), the largest nodule was 7 mm or less in greatest transverse diameter. By increasing the threshold, the percentages of lung cancer diagnoses that would have been missed or delayed and false positives that would have been avoided progressively increased, for example from 1.0% and 15.8% at a 5 mm threshold to 10.5% and 65.8% at an 8 mm threshold, respectively. The projected reductions in postscreening follow-up CT scans and invasive procedures also increased as the threshold was raised. Differences across nodules sizes for lung cancer histology and stage distribution were small but statistically significant. There were no differences across nodule sizes in survival or mortality. Raising the nodule size threshold for a positive screen would substantially reduce false-positive CT screenings and medical resource utilization with a variable impact on screening outcomes. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  17. Doses in pediatric patients undergoing chest and abdomen CT examinations. Preliminary results

    International Nuclear Information System (INIS)

    Jornada, Tiago S.; Silva, Teogenes A. da

    2011-01-01

    Computed tomography (CT) is a non-invasive method of image production that imparts significant doses to a patient, it is expected that pediatric CT examinations will increase the risk of induced cancer in children. In this study the effective doses in a five year-old child submitted to chest or abdomen CT scans were assessed for comparison purposes. The CTEXPO computed program was used with data from routine protocols of a 0 to 13 year-old children in two public hospitals in Belo Horizonte. Hospital A used a Siemens Dual-Slice unit with 80 kV, 41 mA and pitch 2 for chest or abdomen; hospital B used a Multislice GE unit with 120 kV, 45 mA and pitch 1 for chest and 120 kV, 55 mA. and pitch 1 for abdomen. Results of effective doses in a five year-old child were 1.7 and 1.0 mSv in hospital A and 9.1 and 7.2 mSv in hospital B, for chest and abdomen, respectively. Results were compared to the reference effective doses of 7.2 and 5.0 mSv for chest and abdomen respectively that were derived from the air kerma length product values given in ICRP publication 87. Results of hospital A showed that low dose exposures also can be achieved in CT scans of children. Results showed that even a hospital with a modern facility (hospital B) can provided doses higher than reference values if protocols are not adjusted for children. Preliminary results suggested that there is a room for optimizing children exposure submitted to CT scans. (author)

  18. Measurement of four chambers' volumes and ventricular masses by cardiac CT examination

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Motomasa; Naito, Hiroaki; Ohta, Mitsushige; Kozuka, Takahiro; Kito, Yoshitsugu (National Cardiovascular Center, Suita, Osaka (Japan))

    1983-09-01

    Using cardiac computed tomography (CT), the ''mean'' volume of each cardiac chamber and both ventricular masses were calculated from summation of a sliced volume by ungated scans obtained using rapid sequential scanning covering the whole heart. 1. Estimation of a normal value of each chamber's volume was attempted in 20 patients with ischemic heart disease and with normal heart function. The ''mean'' volume of the right atrium (RAMV), right ventricle (RVMV), and left atrium (LAMV) was 22.3 +- 6.5, 40.3 +- 6.5 and 28.7 +- 8.2ml/m/sup 2/, respectively. 2. In 54 patients with valvular heart diseases, each chamber's volume obrained by CT was compared with the grade of tricuspid regurgitation (TR) estimated by ultrasonic Doppler technique or the grade of mitral regurgitation (MR) by left ventriculography (LVG). The RAMV (234 +- 119 ml/m/sup 2/) and the RVMV (101 +- 39 ml/m/sup 2/) were markedly increased in patients with severe TR (grade 3 to 4) (p<0.01). The LAMV (487 +- 231 ml/m/sup 2/) was also increased in patients with severe mitral regurgitation (grade 3 to 4) (p<0.01). 3. In 46 patients with valvular heart diseases, the LVMV by CT was well correlated with end-diastolic volume (EDV) obtained by LVG (r=0.92), and the LVEDVs by ECG gated CT and by LVG showed a fairly good correlation (r=0.95). 4. CT examination was performed before and after surgery in 17 patients with MR or TR for evaluation of the change of chamber volumes. The mean reduction ratio (MRR) of the RAMV after tricuspid annuloplasty, the LVMV after mitral valve plasty, and the LAMV after left atrial plication was 44%, 41%, and 60%, respectively.

  19. Longitudinal tube modulation for chest and abdominal CT examinations: impact on effective patient doses calculations

    Science.gov (United States)

    Zanca, F.; Michielsen, K.; Depuydt, M.; Jacobs, J.; Nens, J.; Lemmens, K.; Oyen, R.; Bosmans, H.

    2011-03-01

    Purpose: In multi-slice CT, manufacturers have implemented automatic tube current modulation (TCM) algorithms. These adjust tube current in the x-y plane (angular modulation) and/or along the z-axis (z-axis modulation) according to the size and attenuation of the scanned body part. Current methods for estimating effective dose (ED) values in CT do not account for such new developments. This study investigated the need to take TCM into account when calculating ED values, using clinical data. Methods: The effect of TCM algorithms as implemented on a GE BrightSpeed 16, a Philips Brilliance 64 and a Siemens Sensation 64 CT scanners was investigated. Here, only z-axis modulation was addressed, considering thorax and abdomen CT examinations collected from 534 adult patients. Commercially available CT dosimetry software (CT expo v.1.7) was used to compute EDTCM (ED accounting for TCM) as the sum of ED of successive slices. A two-step approach was chosen: first we estimated the relative contribution of each slice assuming a constant tube current. Next a weighted average was taken based upon the slice specific tube current value. EDTCM was than compared to patient ED estimated using average mA of all slices. Results and Conclusions: The proposed method is relatively simple and uses as input: the parameters of each protocol, a fitted polynomial function of weighting factors for each slice along the scan length and mA values of the individual patient examination. Results show that z-axis modulation does not have a strong impact on ED for the Siemens and the GE scanner (difference ranges from -4.1 to 3.3 percent); for the Philips scanner the effect was more important, (difference ranges from -8.5 to 6.9 percent), but still all median values approached zero (except for one case, where the median reached -5.6%), suggesting that ED calculation using average mA is in general a good approximation for EDTCM. Higher difference values for the Philips scanner are due to a stronger

  20. Measurements of the ionising radiation level at a nuclear medicine facility performing PET/CT examinations

    International Nuclear Information System (INIS)

    Tulik, P.; Kowalska, M.; Golnik, N.; Budzynska, A.; Dziuk, M.

    2017-01-01

    This paper presents the results of radiation level measurements at workplaces in a nuclear medicine facility performing PET/ CT examinations. This study meticulously determines the staff radiation exposure in a PET/CT facility by tracking the path of patient movement. The measurements of the instantaneous radiation exposure were performed using an electronic radiometer with a proportional counter that was equipped with the option of recording the results on line. The measurements allowed for visualisation of the staff's instantaneous exposure caused by a patient walking through the department after the administration of 18 F-FDG. An estimation of low doses associated with each working step and the exposure during a routine day in the department was possible. The measurements were completed by determining the average radiation level using highly sensitive thermoluminescent detectors. (authors)

  1. Doses from pediatric CT examinations in Norway: are pediatric scan protocols developed and in daily use?

    International Nuclear Information System (INIS)

    Friberg, Eva G.

    2008-01-01

    Doses to pediatric patients from CT examinations are known to be unnecessarily high if scan protocols developed for adult patients are adopted. This overexposure is most often not recognized by the operating radiographer, due to the digital behavior of the imaging system. Use of optimized size-specific pediatric scan protocols is therefore essential to keep the doses at an appropriate level. The aim of this study was to investigate the doses to pediatric patients from CT examinations and to evaluate the level of optimization of the scan protocols. Patient data, applied scan parameters together with the dose parameters volume computed tomography dose index (CTD vol ) and dose length product (DLP) for examinations of the head, chest and abdomen were collected by means of a questionnaire from five university hospitals. The effective dose was estimated from the total DLP by use of region-specific conversion coefficients (E DLP ). Totally 136, 108 and 82 questionnaires were received for examinations of the head, chest and abdomen, respectively. Large variations in patient doses between the hospitals were observed, addressing the need for optimization of the scan protocols in general. Most of the hospitals applied successive lower mAs with decreasing patient age for all scan areas, while the use of lower tube voltage for small patients and a higher tube voltage for large patients were more rarely. This indicates the presence, to a certain level, of size specific scan protocols at some Norwegian hospitals. Focus on developing size-specific scan protocols for pediatric patients are important to reduce the doses and risks associated with pediatric CT examinations. (author)

  2. Diagnostic Reference Levels and Monitoring Practice Can Help Reduce Patient Dose From CT Examinations.

    Science.gov (United States)

    Tonkopi, Elena; Duffy, Susan; Abdolell, Mohamed; Manos, Daria

    2017-05-01

    The purpose of this study is to establish provincial diagnostic reference levels (DRLs) and to determine whether this process may help reduce the patient radiation dose from the most frequently performed CT examinations. We investigated the following CT examinations: head, chest, low-dose chest, abdomen and pelvis, and chest, abdomen, and pelvis examinations. The sample for each protocol included 15 patients of average body weight (mean [± SD], 70 ± 20 kg). The differences in dose between scanners were evaluated using one-way ANOVA. Correlations between dose, scanner age, and the number of detector rows were assessed using the Pearson correlation coefficient. A sample of abdominal and chest examinations were randomized and blinded for review by experienced radiologists who graded diagnostic image quality. Provincial DRLs were calculated as the 75th percentile of patient dose distributions. For hospitals with doses exceeding the DRLs, dose reduction was recommended, followed by another survey. The initial survey included data of 1185 patients, and an additional 180 patients were surveyed after protocol optimization. The differences between the mean values of the dose distributions from each scanner were statistically significant (p examinations. The variation was greatest for low-dose chest CT, with a greater than fivefold difference in the mean dose values noted between scanners. A very weak correlation was found between dose and scanner age or the number of detector rows. Analysis of image quality revealed no statistically significant differences in any scoring categories, with the exception of the noise category in abdominal imaging. Implementation of the DRLs allowed a reduction in patient dose of up to 41% as a result of a protocol change. Establishing provincial DRLs allows an effective reduction in patient dose without resulting in degradation of image quality.

  3. Evaluating doses of multi-slice CT in brain examinations using various methods.

    Science.gov (United States)

    Lin, Hung-Chih; Lai, Te-Jen; Tseng, Hsien-Chun; Lin, Cheng-Hsun; Tseng, Yen-Ling; Chen, Chien-Yi

    2017-12-01

    The effective dose (H E ) and organ or tissue equivalent dose (H T ) of a Rando phantom undergoing two brain computed tomography (CT) examination protocols were evaluated using thermoluminescent dosimeters (TLD-100H) and dose length product (DLP) methods. TLDs were inserted into the correlated positions of an organ or tissue of Rando phantom, such as thyroid, brain, and salivary gland, using (A) axial scan: scanning the maxillae ranging from external auditory meatus to the parietal bone, and (B) helical scan: scanning from the mandible to the parietal bone. CT examinations were performed on a Philips computer tomography (Brilliance CT) at Lukang Christian Hospital. TLDs were measured using a Harshaw 3500 TLD reader. The HT of organ and tissue during the two protocols was discussed. H E were calculated using ICRP 60 and 103 at 2.67 ± 0.18 and 1.89 ± 0.23 mSv based on an axial scan, and 4.70 ± 0.38 and 4.39 ± 0.37 mSv based on a helical scan, respectively. In the DLP method, H E was estimated from CTDI vol that was recorded directly from the console display of the CT unit and then calculated using AAPM 96. Finally, experimental results are compared with those in literature. Radiologists should choose and adjust protocols to prevent unnecessary radiation to patients and satisfying the as low as reasonably achievable (ALARA) principle. These findings will be valuable to patients, physicians, radiologists, and the public.

  4. Radiation Doses in Consecutive CT Examinations from Five University of California Medical Centers.

    Science.gov (United States)

    Smith-Bindman, Rebecca; Moghadassi, Michelle; Wilson, Nicole; Nelson, Thomas R; Boone, John M; Cagnon, Christopher H; Gould, Robert; Hall, David J; Krishnam, Mayil; Lamba, Ramit; McNitt-Gray, Michael; Seibert, Anthony; Miglioretti, Diana L

    2015-10-01

    To summarize data on computed tomographic (CT) radiation doses collected from consecutive CT examinations performed at 12 facilities that can contribute to the creation of reference levels. The study was approved by the institutional review boards of the collaborating institutions and was compliant with HIPAA. Radiation dose metrics were prospectively and electronically collected from 199 656 consecutive CT examinations in 83 181 adults and 3871 consecutive CT examinations in 2609 children at the five University of California medical centers during 2013. The median volume CT dose index (CTDIvol), dose-length product (DLP), and effective dose, along with the interquartile range (IQR), were calculated separately for adults and children and stratified according to anatomic region. Distributions for DLP and effective dose are reported for single-phase examinations, multiphase examinations, and all examinations. For adults, the median CTDIvol was 50 mGy (IQR, 37-62 mGy) for the head, 12 mGy (IQR, 7-17 mGy) for the chest, and 12 mGy (IQR, 8-17 mGy) for the abdomen. The median DLPs for single-phase, multiphase, and all examinations, respectively, were as follows: head, 880 mGy · cm (IQR, 640-1120 mGy · cm), 1550 mGy · cm (IQR, 1150-2130 mGy · cm), and 960 mGy · cm (IQR, 690-1300 mGy · cm); chest, 420 mGy · cm (IQR, 260-610 mGy · cm), 880 mGy · cm (IQR, 570-1430 mGy · cm), and 550 mGy · cm (IQR 320-830 mGy · cm); and abdomen, 580 mGy · cm (IQR, 360-860 mGy · cm), 1220 mGy · cm (IQR, 850-1790 mGy · cm), and 960 mGy · cm (IQR, 600-1460 mGy · cm). Median effective doses for single-phase, multiphase, and all examinations, respectively, were as follows: head, 2 mSv (IQR, 1-3 mSv), 4 mSv (IQR, 3-8 mSv), and 2 mSv (IQR, 2-3 mSv); chest, 9 mSv (IQR, 5-13 mSv), 18 mSv (IQR, 12-29 mSv), and 11 mSv (IQR, 6-18 mSv); and abdomen, 10 mSv (IQR, 6-16 mSv), 22 mSv (IQR, 15-32 mSv), and 17 mSv (IQR, 11-26 mSv). In general, values for children were approximately 50% those

  5. Estimation of effective dose from limited cone beam X-ray CT examination

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, Kazuo; Arai, Yoshinori; Hashimoto, Koji [Nihon Univ., Tokyo (Japan). School of Dentistry; Nishizawa, Kanae

    2000-12-01

    The limited cone beam X-ray CT (Ortho-CT) was developed on the basis of multi-functional panoramic apparatus, SCANORA (Soredex Co. Helsinki Finland). The imaging intensifier (I.I.) was built in this apparatus as a X-ray detection device instead of X-ray film. The signal provided from I.I. was converted from analog into digital by an analog-digital converter and image reconstitution was done as a three-directional image of the dimensions 3.8 cm of width, 3.0 cm height and 3.8 cm depth with the personal computer. The 3DX Multi image micro CT'' (3DX) was developed along similar lines by MORITA Co., Ltd. (Kyoto, JAPAN). In this study, the stochastic effect on organ and tissue caused by examinations using Ortho-CT and 3DX was measured. The effective dose was estimated according to the recommendation of ICRP60 and was compared with those of panoramic radiography and computed tomography. The irradiation conditions were as follows: 85 kV, 10 mA with the filtration of 3 mmAl and added 1 mmCu for Ortho-CT, and 80 kV, 2 mA and the filtration of 3.1 mmAL for 3DX. The measurement of organ and tissue dose was performed using an anthropomorphic Rando woman phantom (Alderson Research Laboratories Co., Stanfora, CN), as well as by using two different type of thermoluminescent dosimeter (TLD); Panasonic UD-170A (BeO) and UD-110S (CaSO{sub 4}: Tm). The UD-170A was for dose measurement of the inner useful X-ray beams, while the UD-110S was for outer beams. The measured organ and tissue were those recommended with ICRP60 (gonad, breast, bone marrow, lung, thyroid gland, esophagus, stomach, colon, liver, bladder, skin, brain, thymus, adrenal, kidney, spleen, pancrease, upper large intestine, uterus, eyes and major salivary gland). The imaging by Orhto-CT was made in the left maxillary 1st molar, left mandibular 1st molar and temporomandibular joint. 3DX measurement was made in the maxillary incisor region and middle ear regions other than the regions mentioned above. The skin

  6. The Use of CT Scans in Estimating Age at Death by Examining the Extent of Ectocranial Suture Closure

    DEFF Research Database (Denmark)

    Boyd, Kristen Leigh; Villa, Chiara; Lynnerup, Niels

    2015-01-01

    We examined the utility of CT scans in the evaluation of degree of ectocranial suture closure. Five cranial points (left and right midcoronal positions, left and right midlambdoidal positions, and the lambda) were evaluated in 231 CT scans using a three-point scoring system (open, partial closed,...

  7. Estimation of patient dose in 18 F-FDG and 18 F-FDOPA PET/CT examinations

    Directory of Open Access Journals (Sweden)

    Aruna Kaushik

    2013-01-01

    Full Text Available Purpose: To estimate specific organ and effective doses to patients resulting from the 18 F-FDG ( 18 F-2-deoxy-D-glucose and 18 F-FDOPA (6-fluoro-( 18 F-L-3, 4-dihydroxyphenylalanine PET/CT examinations for whole body and brain. Materials and Methods: Three protocols for whole body and three for brain PET/CT were used. The CTDI values were measured using standard head and body CT phantoms and also computed using a software CT-Expo for dose evaluation from the CT component. OLINDA software based on MIRD method was used for estimating doses from the PET component of the PET/CT examination. Results: The organ doses from 18 F-FDG and 18 F-FDOPA whole body and brain PET/CT studies were estimated. The total effective dose from a typical protocol of whole body PET/CT examination was 14.4 mSv for females and 11.8 mSv for male patients from 18 F-FDG, whereas it was 11 mSv for female and 9.1 mSv for male patients from 18 F-FDOPA. The total effective doses from a typical protocol for PET/CT studies of brain was 6.5 mSv for females and 5.1 mSv for males from 18 F-FDG whereas it was 3.7 mSv for females and 2.8 mSv for males from 18 F-FDOPA. Conclusions: The effective radiation doses from whole body PET/CT examination was approximately 4-8 times higher than the background radiation dose from both 18 F-FDG and 18 F-FDOPA scans, while it was 1-3 times the background radiation dose from PET/CT scans of brain.

  8. Estimation of patient dose in (18)F-FDG and (18)F-FDOPA PET/CT examinations.

    Science.gov (United States)

    Kaushik, Aruna; Jaimini, Abhinav; Tripathi, Madhavi; D'Souza, Maria; Sharma, Rajnish; Mishra, Anil K; Mondal, Anupam; Dwarakanath, Bilikere S

    2013-01-01

    To estimate specific organ and effective doses to patients resulting from the (18)F-FDG ((18)F-2-deoxy-D-glucose) and (18)F-FDOPA (6-fluoro-((18)F)-L-3, 4-dihydroxyphenylalanine) PET/CT examinations for whole body and brain. Three protocols for whole body and three for brain PET/CT were used. The CTDI values were measured using standard head and body CT phantoms and also computed using a software CT-Expo for dose evaluation from the CT component. OLINDA software based on MIRD method was used for estimating doses from the PET component of the PET/CT examination. The organ doses from (18)F-FDG and (18)F-FDOPA whole body and brain PET/CT studies were estimated. The total effective dose from a typical protocol of whole body PET/CT examination was 14.4 mSv for females and 11.8 mSv for male patients from (18)F-FDG, whereas it was 11 mSv for female and 9.1 mSv for male patients from (18)F-FDOPA. The total effective doses from a typical protocol for PET/CT studies of brain was 6.5 mSv for females and 5.1 mSv for males from (18)F-FDG whereas it was 3.7 mSv for females and 2.8 mSv for males from (18)F-FDOPA. The effective radiation doses from whole body PET/CT examination was approximately 4-8 times higher than the background radiation dose from both (18)F-FDG and (18)F-FDOPA scans, while it was 1-3 times the background radiation dose from PET/CT scans of brain.

  9. Sensation of smell and taste during intravenous injection of iodinated contrast media in CT examinations

    Science.gov (United States)

    Yamaguchi, Naoto; Yamaguchi, Aiko; Nagasawa, Naoki; Taketomi-Takahashi, Ayako; Suto, Takayuki; Tsushima, Yoshito

    2017-01-01

    Objective: To assess the incidence and types of sensation of smell and taste during i.v. injection of five kinds of contrast media (CM) in CT examinations. Methods: 735 patients who underwent contrast-enhanced CT (CE-CT) between 14 March 2016 and 5 April 2016 were enrolled. Medical staff asked patients whether they felt heat sensation and sensation of smell and taste during i.v. injection of CM (one of the following: iopromide, iomeprol, iopamidol, iohexol and ioversol) after their CE-CT. If the patients stated having felt the sensation of smell or taste, they were also asked what kind of smell or taste they sensed. Next, 30 ml of each CM was poured into high-purity pet cups for radiological technologists to smell directly. Radiological technologists were asked whether or not each CM had any smell. Results: The sensations of smell and taste incidence for iopromide were 24.3% and 18.9%, respectively, which were significantly higher than those for other CM (p < 0.05). The highest incidence of the sensation of smell was medicine-ish, and the most frequently noted taste was bitterness. All radiological technologists could directly smell only iopromide, which has an ether group on a side chain and fewer hydroxyl groups. Conclusion: Iopromide showed a higher incidence of sensation of smell and taste than other CM. Advances in knowledge: This was the first investigation of sensation of smell and taste during i.v. injection of CM, and a specific CM showed a higher incidence, which is suspected to be due to its chemical structure. PMID:27805431

  10. Sensation of smell and taste during intravenous injection of iodinated contrast media in CT examinations.

    Science.gov (United States)

    Yamaguchi, Naoto; Fukushima, Yasuhiro; Yamaguchi, Aiko; Nagasawa, Naoki; Taketomi-Takahashi, Ayako; Suto, Takayuki; Tsushima, Yoshito

    2017-01-01

    To assess the incidence and types of sensation of smell and taste during i.v. injection of five kinds of contrast media (CM) in CT examinations. 735 patients who underwent contrast-enhanced CT (CE-CT) between 14 March 2016 and 5 April 2016 were enrolled. Medical staff asked patients whether they felt heat sensation and sensation of smell and taste during i.v. injection of CM (one of the following: iopromide, iomeprol, iopamidol, iohexol and ioversol) after their CE-CT. If the patients stated having felt the sensation of smell or taste, they were also asked what kind of smell or taste they sensed. Next, 30 ml of each CM was poured into high-purity pet cups for radiological technologists to smell directly. Radiological technologists were asked whether or not each CM had any smell. The sensations of smell and taste incidence for iopromide were 24.3% and 18.9%, respectively, which were significantly higher than those for other CM (p smell was medicine-ish, and the most frequently noted taste was bitterness. All radiological technologists could directly smell only iopromide, which has an ether group on a side chain and fewer hydroxyl groups. Iopromide showed a higher incidence of sensation of smell and taste than other CM. Advances in knowledge: This was the first investigation of sensation of smell and taste during i.v. injection of CM, and a specific CM showed a higher incidence, which is suspected to be due to its chemical structure.

  11. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    Science.gov (United States)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  12. Results of a questionnaire survey on window setting and FOV on CT images of examinations

    International Nuclear Information System (INIS)

    Anzui, Maya; Asano, Kazushige; Goto, Takahiro; Sekitani, Toshinori; Tsujioka, Katsumi; Kawaguchi, Daisuke; Narumi, Tatsuki

    2008-01-01

    The use of CT as a general examination has spread widely and is even used in small institutions. However, it is difficult to determine the current situation of each institution. Therefore, we employed a questionnaire to investigate the current situation of a variety of institutions. From the results of the questionnaire, we determined that the window setting was difficult for beginner technologists. In addition, in many institutions, radiological technologists did not always use the same display field of view (FOV) for the same patient. From this questionnaire, we were able to determine the present conditions in each institution. We consider these results very useful. (author)

  13. Osteometrical and CT examination of the Japanese wolf [Canis hodophilax] skull

    International Nuclear Information System (INIS)

    Endo, H.; Obara, I.; Yoshida, T.; Kurohmaru, M.; Hayshi, Y.; Suzuki, N.

    1997-01-01

    The skulls of Japanese wolf (Canis hodophilax) were osteometrically examined and compared with those of Akita-Inu. The skull total length was not statistically different between two species. However, significant differences were demonstrated between two species in some ratios concerning the frontal bone. CT examination was carried out in the Japanese wolf skull. The data indicated that the frontal sinus is not be largely developed and compressed in the dorso-ventral direction in parasagittal area. The narrow frontal sinus fitted to external shape of the frontal bone. The cribriform plate had a well-developed complicated structure in a caudal part of the ethmoid bone. These data will be useful to examine the respiratory function and the olfactory sense in the Japanese wolf

  14. An assessment of the dose received by children from CT examinations along with the quality control parameters from a conventional CT system

    International Nuclear Information System (INIS)

    Sadeghyani, T.; Hashemi Malayeri, B.; Hashemi, H.; Sharafi, A. A.

    2005-01-01

    In 2000, the UNSCEAR reported that CT constitutes 5% of all the medical x-ray examinations and it contributes 34% of the resultant collective dose worldwide. Children are more sensitive to the ionizing radiations than adults. So, routine quality control tests are expected to be carried out periodically on the CT scanners. The aim of this research was to estimate the effective doses received by the children below two years of age from routine CT examinations carried out at an educational imaging center in Tehran. It was also aimed to evaluate the quality control parameters of the mentioned CT scanner at the same time. Materials and Methods: In this study, the Computed Tomography Dose Index were measured at the central axis of the CT gantry in air and in the standard quality control phantoms of the head and body (as recommended by the FDA) using a pencil ionization chamber and LiF TLD pellets for a single scan. By using the measured Computed Tomography Dose Index values and the IrnPACT software, the effective doses were calculated for every routine CT examination protocol. In this study, the quality control parameters such as noise, CT number calibration, high and low contrast resolution and the flatness of the CT image were also evaluated. These parameters were also measured using standard procedures and test objects. Results: The effective dose estimated in this research ranged from 2.05 to 21.45 and 2.05 to 15.7 mSv for the female and male children, respectively. The measured values of the Computed Tomography Dose Index in the standard head and body phantoms were 20.6) 2.01 and 11.13 f 1.04 mGy1100 mAs, respectively. The high and low contrast resolution was estimated to be 0.8 mm and 1.0 rnm, respectively. Conclusion: The estimated values of the effective doses in this research were less than the values reported for the Netherlands, the USA, Germany and were comparable with the values reported in the UK. The measured Computed Tomography Dose Index values were 11

  15. Multiple mechanisms quench passive spiral galaxies

    Science.gov (United States)

    Fraser-McKelvie, Amelia; Brown, Michael J. I.; Pimbblet, Kevin; Dolley, Tim; Bonne, Nicolas J.

    2018-02-01

    We examine the properties of a sample of 35 nearby passive spiral galaxies in order to determine their dominant quenching mechanism(s). All five low-mass (M⋆ environments. We postulate that cluster-scale gas stripping and heating mechanisms operating only in rich clusters are required to quench low-mass passive spirals, and ram-pressure stripping and strangulation are obvious candidates. For higher mass passive spirals, while trends are present, the story is less clear. The passive spiral bar fraction is high: 74 ± 15 per cent, compared with 36 ± 5 per cent for a mass, redshift and T-type matched comparison sample of star-forming spiral galaxies. The high mass passive spirals occur mostly, but not exclusively, in groups, and can be central or satellite galaxies. The passive spiral group fraction of 74 ± 15 per cent is similar to that of the comparison sample of star-forming galaxies at 61 ± 7 per cent. We find evidence for both quenching via internal structure and environment in our passive spiral sample, though some galaxies have evidence of neither. From this, we conclude no one mechanism is responsible for quenching star formation in passive spiral galaxies - rather, a mixture of mechanisms is required to produce the passive spiral distribution we see today.

  16. Estimation of patient dose in abdominal CT examination in some Sudanese hospitals

    International Nuclear Information System (INIS)

    Adam, Ebthal Adam Shikhalden

    2016-04-01

    The use of CT in medical diagnosis delivers radiation doses to patients that are higher than those from other radiological procedures. The aim of this study was to estimate radiation doses in abdomen CT examinations of patients in two Sudanese hospitals. Details were obtained from approximately 80 CT examinations and included all age groups ( adults and pediatric). The results from the two hospitals were compared with each other as well as with the IAEA guidance level for this particular investigation. The estimation of radiation doses were carried out by calculating volume dose index (CTD1vol), dose length product (DLP), doses to some organs of interest and effective dose (E) using the software program C T EXPO V2.1 . The study showed that the mean DLP of the one hospitals ASH is 1736.7 mGy.cm which is by far much higher than that for the other hospital NMDC which stands at 185.3 mGy.cm, as well as higher than the IAEA level which is 696 mGy.cm. The study showed that the mean CTD1vol for patients in ASH is 36.2 mGy which again higher than that for the other hospital which is 3.9 mGy and higher than the IAEA level which is 10.9 mGy calculating the effective dose for patients in the two hospitals reveals that the mean effective dose of patient in one hospital (ASH) is 26.25 mSv, which is quite high compared with other hospital (NMDC), which has the mean value of 2.8 mGv and also higher than the IAEA level from this investigation which is 7.6 mSv. Regarding organ doses, the study showed that organ doses in hospital ASH are always higher than that calculated in hospital NMDC and the highest doses in both hospital were delivered to the kidneys with mean values of 50.24 mGy and 5045 mGy for the two hospitals respectively. The study showed that there is an urgent need for optimizing patient doses in such CT examinations. This can be ensured by providing training and retraining for workers and conducting quality control measurements and preventive maintenance regularly so

  17. ESTIMATION OF FEMALE RADIATION DOSES AND BREAST CANCER RISK FROM CHEST CT EXAMINATIONS.

    Science.gov (United States)

    Lahham, Adnan; ALMasri, Hussein; Kameel, Saleh

    2017-12-11

    Breast organ doses, effective doses and lifetime attributable risk (LAR) of breast cancer from chest CT scans are presented for 200 female patients surveyed from 10 hospitals in the West Bank and Gaza Strip, Palestine. Patient data were collected and organized in a database from May to November 2016. Data include age (15-80 years), weight, height, and calculated body mass index. Exposure data were also recorded for every examination. Exposure data includes milliampere-second (mAs), X-ray tube kilovoltage (kVp), computed tomography dose index, dose length product, manufacturer, name and type of operated CT scanner. Organ and effective doses were evaluated using a web-based commercially available Monte Carlo software: VirtualDose™CT, a product of Virtual Phantoms, Inc. The software utilizes male and female tissue equivalent phantoms of all ages and sizes including pregnant patients. The corresponding phantom was selected for every patient according to patient's tomographic parameters. Calculated organ doses were used to estimate the LAR of breast cancer according to BEIR VII Phase 2 report. It was found that radiation doses resulting from the same exam vary widely between different hospitals, depending on the parameters used and the type of scanner. For all patients, the breast organ dose ranged from 6.5 to 28 mGy per examination, with an average breast organ dose of 15 mGy. The effective dose from chest CT scan per examination ranged from 3 to 14.7 mSv with an average of 7 mSv. For younger females (15-29 years), the LAR of breast cancer risk was estimated to be around 0.05%. For older female patients (60-79 years), the risk was ~0.001%. It was found that LAR decreases remarkably with patient's age. Values obtained in this study vary between hospitals, they are generally low and consistent with other studies reported worldwide. © The Author(s) 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Does iterative reconstruction lower CT radiation dose: evaluation of 15,000 examinations.

    Science.gov (United States)

    Noël, Peter B; Renger, Bernhard; Fiebich, Martin; Münzel, Daniela; Fingerle, Alexander A; Rummeny, Ernst J; Dobritz, Martin

    2013-01-01

    Evaluation of 15,000 computed tomography (CT) examinations to investigate if iterative reconstruction (IR) reduces sustainably radiation exposure. Information from 15,000 CT examinations was collected, including all aspects of the exams such as scan parameter, patient information, and reconstruction instructions. The examinations were acquired between January 2010 and December 2012, while after 15 months a first generation IR algorithm was installed. To collect the necessary information from PACS, RIS, MPPS and structured reports a Dose Monitoring System was developed. To harvest all possible information an optical character recognition system was integrated, for example to collect information from the screenshot CT-dose report. The tool transfers all data to a database for further processing such as the calculation of effective dose and organ doses. To evaluate if IR provides a sustainable dose reduction, the effective dose values were statistically analyzed with respect to protocol type, diagnostic indication, and patient population. IR has the potential to reduce radiation dose significantly. Before clinical introduction of IR the average effective dose was 10.1±7.8mSv and with IR 8.9±7.1mSv (p*=0.01). Especially in CTA, with the possibility to use kV reduction protocols, such as in aortic CTAs (before IR: average14.2±7.8mSv; median11.4mSv /with IR:average9.9±7.4mSv; median7.4mSv), or pulmonary CTAs (before IR: average9.7±6.2mSV; median7.7mSv /with IR: average6.4±4.7mSv; median4.8mSv) the dose reduction effect is significant(p*=0.01). On the contrary for unenhanced low-dose scans of the cranial (for example sinuses) the reduction is not significant (before IR:average6.6±5.8mSv; median3.9mSv/with IR:average6.0±3.1mSV; median3.2mSv). The dose aspect remains a priority in CT research. Iterative reconstruction algorithms reduce sustainably and significantly radiation dose in the clinical routine. Our results illustrate that not only in studies with a limited

  19. Content analysis of physical examination templates in electronic health records using SNOMED CT.

    Science.gov (United States)

    Gøeg, Kirstine Rosenbeck; Chen, Rong; Højen, Anne Randorff; Elberg, Pia

    2014-10-01

    Most electronic health record (EHR) systems are built on proprietary information models and terminology, which makes achieving semantic interoperability a challenge. Solving interoperability problems requires well-defined standards. In contrast, the need to support clinical work practice requires a local customization of EHR systems. Consequently, contrasting goals may be evident in EHR template design because customization means that local EHR organizations can define their own templates, whereas standardization implies consensus at some level. To explore the complexity of balancing these two goals, this study analyzes the differences and similarities between templates in use today. A similarity analysis was developed on the basis of SNOMED CT. The analysis was performed on four physical examination templates from Denmark and Sweden. The semantic relationships in SNOMED CT were used to quantify similarities and differences. Moreover, the analysis used these identified similarities to investigate the common content of a physical examination template. The analysis showed that there were both similarities and differences in physical examination templates, and the size of the templates varied from 18 to 49 fields. In the SNOMED CT analysis, exact matches and terminology similarities were represented in all template pairs. The number of exact matches ranged from 7 to 24. Moreover, the number of unrelated fields differed a lot from 1/18 to 22/35. Cross-country comparisons tended to have more unrelated content than within-country comparisons. On the basis of identified similarities, it was possible to define the common content of a physical examination. Nevertheless, a complete view on the physical examination required the inclusion of both exact matches and terminology similarities. This study revealed that a core set of items representing the physical examination templates can be generated when the analysis takes into account not only exact matches but also terminology

  20. Cardiac-CT and Cardiac-MR examinations cost analysis, based on data of four Italian Centers.

    Science.gov (United States)

    Centonze, Maurizio; Lorenzin, Giuseppe; Francesconi, Andrea; Cademartiri, Filippo; Casagranda, Giulia; Fusaro, Michele; Ligabue, Guido; Zanetti, Giovanna; Spanti, Demetrio; De Cobelli, Francesco

    2016-01-01

    To establish the appropriate number of Cardiac-CT and Cardio-MR examinations, to determine an economically justified and sustainable investment in these two technologies, for an exclusive cardiologic use. From July 2013 to July 2014, through a survey in four different Italian Departments of Radiology, data on the costs of Cardiac-CT and Cardiac-MR examinations were collected. For the evaluation of the costs of examinations, it was used an analytical accounting system, considering only the direct costs (consumables, health personnel work time, equipment amortization/maintenance) and other costs (utilities, services, etc.). Indirect costs (general costs) were not assessed. It was made a simulation, assuming an exclusive use of the CT and MR equipments for Cardiac-CT and Cardiac-MR examinations, calculating the annual number necessary to arrive at the Break Even Point (BEP: the point at which cost or expenses and revenue are equal). On the basis of the CT costs, in order to reach the BEP, performing only Cardiac-CT examinations, an average of 2641-2752 examinations/year is needed. The annual time commitment of the Medical Professional to ensure the number of examinations to reach the BEP is 2625-2750 h/year, equivalent to two Medical Doctors in a Cardiology Department. The recent Cardiac-CT Italian Registry, in the period January-June 2011, reports a number of examinations of 3455 patients in 47 different Centers, distributed throughout the whole national territory. With regard to MR, in order to reach the BEP, performing only Cardiac-MR examinations, an average of 2435-3123 examinations/year is needed. The annual time commitment of the Medical Professional to ensure the number of examinations to reach the BEP is 2437-3125 h/year, equivalent to two Medical Doctors in a Cardiology Department. The recent Cardiac-MR Italian Registry reports a number of examinations of 3776 patients in 40 Centers, distributed throughout the whole national territory. This research has

  1. Estimating organ doses from tube current modulated CT examinations using a generalized linear model.

    Science.gov (United States)

    Bostani, Maryam; McMillan, Kyle; Lu, Peiyun; Kim, Grace Hyun J; Cody, Dianna; Arbique, Gary; Greenberg, S Bruce; DeMarco, John J; Cagnon, Chris H; McNitt-Gray, Michael F

    2017-04-01

    Currently, available Computed Tomography dose metrics are mostly based on fixed tube current Monte Carlo (MC) simulations and/or physical measurements such as the size specific dose estimate (SSDE). In addition to not being able to account for Tube Current Modulation (TCM), these dose metrics do not represent actual patient dose. The purpose of this study was to generate and evaluate a dose estimation model based on the Generalized Linear Model (GLM), which extends the ability to estimate organ dose from tube current modulated examinations by incorporating regional descriptors of patient size, scanner output, and other scan-specific variables as needed. The collection of a total of 332 patient CT scans at four different institutions was approved by each institution's IRB and used to generate and test organ dose estimation models. The patient population consisted of pediatric and adult patients and included thoracic and abdomen/pelvis scans. The scans were performed on three different CT scanner systems. Manual segmentation of organs, depending on the examined anatomy, was performed on each patient's image series. In addition to the collected images, detailed TCM data were collected for all patients scanned on Siemens CT scanners, while for all GE and Toshiba patients, data representing z-axis-only TCM, extracted from the DICOM header of the images, were used for TCM simulations. A validated MC dosimetry package was used to perform detailed simulation of CT examinations on all 332 patient models to estimate dose to each segmented organ (lungs, breasts, liver, spleen, and kidneys), denoted as reference organ dose values. Approximately 60% of the data were used to train a dose estimation model, while the remaining 40% was used to evaluate performance. Two different methodologies were explored using GLM to generate a dose estimation model: (a) using the conventional exponential relationship between normalized organ dose and size with regional water equivalent diameter

  2. Learning to interpret the extracardiac findings on coronary CT angiography examinations.

    Science.gov (United States)

    Teague, Shawn D; Rissing, Stacy; Mahenthiran, Jothiharan; Achenbach, Stephan

    2012-01-01

    Coronary computed tomography angiography (CTA) plays an important role in the identification of coronary artery disease in low- to intermediate-risk patients. Even with a "restrictive" field of view, coronary CTA data sets will include visualization of structures adjacent to the heart, including the thoracic great vessels, pericardium, mediastinum, lungs, and bones. CT images enable detailed assessment of these structures, at times identifying a potential noncoronary cause of the patient's presenting symptom. The reported incidence of extracardiac findings on coronary CTA is as high as 53%-67%. Complete evaluation of the examination requires scrutiny of the soft tissues, lung tissues, and bones, both in the chest and adjacent abdomen. It is important to adjust the CT window display settings at various stages of the interpretation process to evaluate all potential extracardiac disease. Although in-depth radiology training would be required to correctly identify and interpret all anomalies, this article serves as an overview and guide to evaluation of the extracardiac structures included on a coronary CTA examination. Correct interpretation of extracardiac findings is critical because a false positive interpretation can lead to unnecessary testing and treatment that can be as harmful as a false negative interpretation. Most importantly, if the cardiac findings do not explain the patient's symptoms, an alternative cause should be specifically sought to appropriately manage the patient. Copyright © 2012 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  3. Evaluation of the efficiency of bismuth breast shield in CT chest paediatric examinations

    International Nuclear Information System (INIS)

    Sevillano, D.; Espana, M. L.; Castro, P.; Minguez, C.; Albi, G.; Garcia, E.; Lopez Franco, P.

    2006-01-01

    The aim of this study is to evaluate the efficiency of bismuth breast shield in CT chest paediatric examinations when automatic exposure control techniques are used. The influence in the radiation dose and the image quality has been evaluated with and without the breast shield in the scoutview. In addition the radiation dose in shielded and non-shielded areas has been compared. Measurements were made in a 16 cm diameter cylindrical PMMA phantom simulating a newborn, and older children were simulated controlling the maximum intensities allowed by the automatic exposure control system AutomA. The highest dose reduction (59%) was obtained with AutomA system and when the breast shield is not used in the scoutview. This reduction in the radiation dose does not mean a significant increase of noise level. The use of the breast shield in the scoutview yielded an increase in the radiation dose in non-shielded areas. The use of bismuth breast shield is recommended only after the scoutview in order to optimise the radiation dose in CT chest paediatric examination when using automatic exposure control AutomA. (Author)

  4. Multislice spiral computed tomography imaging in congenital inner ear malformations.

    Science.gov (United States)

    Ma, Hui; Han, Ping; Liang, Bo; Tian, Zhi-liang; Lei, Zi-qiao; Kong, Wei-jia; Feng, Gan-sheng

    2008-01-01

    The purpose of this study is to evaluate the usefulness of multislice spiral computed tomography (CT) in the diagnosis of congenital inner ear malformations. Forty-four patients with sensorineural hearing loss were examined on a Somatom Sensation 16 (Siemens) CT scanner. The 3-dimensional reconstructions and multiplanar reformation (MPR) were performed using the volume-rendering technique (VRT) on the workstation. Of the 44 patients examined for this study, 25 patients were found to be normal and 19 patients (36 ears) were diagnosed with congenital inner ear malformations. Of the malformations, the axial, MPR, and VRT images can all display the site and degree in 33 of the ears. Volume-rendering technique images were superior to the axial images in displaying the malformations in 3 ears with small lateral semicircular canal malformations. The common malformations were Michel deformity (1 ear), common cavity deformity (3 ears), incomplete partition I (3 ears), incomplete partition II (Mondini deformity) (5 ears), vestibular and semicircular canal malformations (14 ears), enlarged vestibular aqueduct (16 ears, 6 of which had other malformations), and internal auditory canal malformation (8 ears, all accompanied by other malformations). Multislice spiral CT allows a comprehensively assessment of various congenital inner ear malformations through high-quality MPR and VRT reconstructions. Volume-rendering technique images can display the site and degree of the malformation 3-dimensionally and intuitionisticly. This is very useful to the cochlear implantation.

  5. [Determination of the effective dose for CT examinations and influence of the setup parameters].

    Science.gov (United States)

    Koller, F; Roth, J

    2007-01-01

    CT examinations are considered to be high dose applications in radiation diagnostics. Consequently, radiation exposure and its potential reduction are an important issue. The aim of this paper is to determine effective doses for CT examinations under clinical conditions. The effective doses were determined from organ dose measurements with an optimal amount of effort. The measured point doses in the various organs in an anthropomorphic phantom were weighted with respect to morphology and location in the radiation field and were averaged to obtain the organ doses. These doses together with the individual radiation sensitivities were able to be used to calculate the effective dose. The following examinations were taken into consideration: thorax, abdomen and skull. Only one parameter was changed for each measurement (the high voltage of the X-ray tube, the pitch, the collimation, or the automatic adjustment of the tube current to correct the individual absorption in the phantom). The effective doses for the thorax examinations were between 5 and 7 mSv, and for the abdomen between 8 and 15 mSv depending on the technique and parameters. In some of the organs the organ doses can be in excess of 25 mSv. Our results were compared to the corresponding results of two commercial computer programs for dose calculations. The calculated effective doses generally showed lower values. It is possible to determine the effective dose from 24-point dose measurements by optimizing the choice of measuring location in the phantom. The individual adaptation of parameters such as tube voltage, exposure, pitch, collimated slice thickness, and investigation volume must be taken into consideration from case to case.

  6. The development of a guidance level for patient dose for CT examinations in Korea

    International Nuclear Information System (INIS)

    Choi, J. H.; Cha, S. H.; Lee, K. Y.; Shin, D. C.; Kang, J. H.; Kim, Y. H.; Kim, K. H.; Cho, P. K.

    2010-01-01

    The primary goal of this study was to analyse the state of patient doses in the field of computed tomography (CT) examinations in the Republic of Korea. All survey data including the CT applications and patient dose details were obtained from general hospitals registered in the Korean Hospital Association. The systematic analysis of the patient dose survey gives target values of the weighted computed tomography dose index (CTDI w ) and the dose-length product (DLP). The targeted CTDI w values were 69, 69, 31, 19, 44, 25, 24, 20, 2, 19 and 19 mGy for the brain non-contrast enhancement (BNCE), brain contrast enhancement (BCE), neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. The targeted DLP values were 1056, 2112, 762, 1234, 1338, 2794, 2742, 2378, 2836, 1844 and 1939 mGy cm for the BNCE, BCE, neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. Comparing with the EUR recommendation, especially in the DLP, the adjustment of the total scan phase frequency and the shortening of the scan phase in each scan phase are needed to reduce the patients radiation exposure to international standards. (authors)

  7. Double reading of current chest CT examinations: Clinical importance of changes to radiology reports.

    Science.gov (United States)

    Lauritzen, Peter M; Stavem, Knut; Andersen, Jack Gunnar; Stokke, Mali Victoria; Tennstrand, Anne Lise; Bjerke, Gisle; Hurlen, Petter; Sandbæk, Gunnar; Dahl, Fredrik A; Gulbrandsen, Pål

    2016-01-01

    Misinterpretation of radiological examinations is an important contributing factor to diagnostic errors. Double reading reduces interpretation errors and increases sensitivity. Consultant radiologists in Norwegian hospitals submit 39% of computed tomography (CT) reports for quality assurance by double reading. Our objective was to estimate the proportion of radiology reports that were changed during double reading and to assess the potential clinical impact of these changes. In this retrospective cross-sectional study we acquired preliminary and final reports from 1023 consecutive double read chest CT examinations conducted at five public hospitals. The preliminary and final reports were compared for changes in content. Three experienced pulmonologists independently rated the clinical importance of these changes. The severity of the radiological findings in clinically important changes was classified as increased, unchanged, or decreased. Changes were classified as clinically important in 91 (9%) of 1023 reports. Of these: 3 were critical (demanding immediate action), 15 were major (implying a change in treatment) and 73 were intermediate (affecting subsequent investigations). More clinically important changes were made to urgent examinations and less to female first readers. Chest radiologist made more clinically important changes than other second readers. The severity of the radiological findings was increased in 73 (80%) of the clinically important changes. A 9% rate of clinically important changes made during double reading may justify quality assurance of radiological interpretation. Using expert second readers and targeting a selection of urgent cases prospectively may increase the yield of discrepant cases and reduce harm to patients. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  8. Results of the Austrian CT dose study 2010. Typical effective doses of the most frequent CT examinations; Ergebnisse der Oesterreichischen CT-Dosisstudie 2010. Effektive Dosen der haeufigsten CT-Untersuchungen und Unterschiede zwischen Anwendern

    Energy Technology Data Exchange (ETDEWEB)

    Homolka, Peter; Leithner, Robert; Billinger, Jochen [Medizinische Universitaet Wien (Austria). Zentrum fuer Medizinische Physik und Biomedizinische Technik; Gruber, Michael [Medizinische Universitaet Wien (Austria). Universitaetsklinik fuer Radiologie und Nuklearmedizin

    2014-10-01

    Purpose: To determine typical doses from common CT examinations of standard sized adult patients and their variability between CT operators for common CT indications. Materials and Methods: In a nationwide Austrian CT dose survey doses from approx. 10,000 common CT examinations of adults during 2009 and 2010 were collected and 'typical' radiation doses to the 'average patient', which turned out to have 75.6 kg body mass, calculated. Conversion coefficients from DLP to effective dose were determined and effective doses calculated according to ICRP 103. Variations of typically applied doses to the 'average patient' were expressed as ratios between 90{sup th} and 10{sup th} percentile (inter-percentile width, IPW90/10), 1st and 3{sup rd} quartile (IPW75/25), and Maximum/Minimum. Results: Median effective doses to the average patients for standard head and neck scans were 1.8 mSv (cervical spine), 1.9 mSv (brain: trauma/bleeding, stroke) to 2.2 mSv (brain: masses) with typical variation between facilities of a factor 2.5 (IPW90/10) and 1.7 (IPW75/25). In the thorax region doses were 6.4 to 6.8 mSv (pulmonary embolism, pneumonia and inflammation, oncologic scans), the variation between facilities was by a factor of 2.1 (IPW90/10) and 1.5 (IPW75/25), respectively. In the abdominal region median effective doses from 6.5 mSv (kidney stone search) to 22 mSv (liver lesions) were found (acute abdomen, staging/metastases, lumbar spine: 9-12 mSv; oncologic abdomen plus chest 16 mSv; renal tumor 20 mSv). Variation factors between facilities were on average for abdominal scans 2.7 (IPW90/10) and 1.8 (IPW75/25). Conclusion: Variations between CT operators are generally moderate for most operators, but in some indications the ratio between the minimum and the maximum of average dose to the typical standard patients exceeds a factor of 4 or even 5. Therefore, comparing average doses to Diagnostic Reference Levels (DRLs) and optimizing protocols need to

  9. Focal breast lesions in clinical CT examinations of the chest. A retrospective analysis; Senologische Befunde bei CT-Untersuchungen des Thorax. Eine retrospektive Auswertung

    Energy Technology Data Exchange (ETDEWEB)

    Krug, Kathrin Barbara; Houbois, Christian; Grinstein, Olga; Borggrefe, Jan; Puesken, Michael; Maintz, David [Cologne Univ. Medical School, Cologne (Germany). Dept. of Diagnostical and Interventional Radiology; Hanstein, Bettina; Malter, Wolfram [Cologne Univ. Medical School, Cologne (Germany). Breast Center and Dept. of Obstetrics and Gynecology; Hellmich, Martin [Cologne Univ. (Germany). Inst. of Medical Statistics, Informatics and Epidemiology

    2017-10-15

    Based on radiological reports, the percentage of breast cancers visualized as incidental findings in routine CT examinations is estimated at ≤2%. In view of the rising number of CT examinations and the high prevalence of breast cancer, it was the goal of the present study to verify the frequency and image morphology of false-negative senological CT findings. All first contrast-enhanced CT examinations of the chest in adult female patients carried out in 2012 were retrospectively included. A senior radiologist systematically assessed the presence of breast lesions on all CT images using the BI-RADS system. All BI-RADS ≥3 notations were evaluated by a second senior radiologist. A consensus was obtained in case of differing BI-RADS assessments. Reference diagnoses were elaborated based on all available clinical, radiological and pathological data. The findings of the CT reports were classified according to the BI-RADS system and were compared with the retrospective consensus findings as well as with the reference diagnoses. The range of indications comprised a broad spectrum including staging and follow-up examinations of solid tumors/lymphoma (N = 701, 59.9 %) and vascular (190, 16.2 %), inflammatory (48, 4.1 %) and pulmonologic (22, 1.9 %) issues. BI-RADS 1/2 classifications were present in 92.5 % and BI-RADS 6 classifications were assessed in 1.7 % of the 1170 included examinations. 68 patients (5.8 %) had at least one lesion retrospectively classified as BI-RADS 3 - 5. The histological potential was known in 57 of these lesions as benign (46, 3.9 %) or malignant (11, 0.9 %). 13 BI-RADS 4/5 consensus assessments (1.1 %) were false-positive. 2 of the 10 lesions classified as being malignant based on the further clinical and radiological course were not mentioned in the written CT reports (0.2 %). Both false-negative CT reports were therapeutically and prognostically irrelevant. The relative frequency of BI-RADS 3 - 5 findings was 5.8 %. It reflects the situation

  10. Improved assessment of mediastinal and pulmonary pathologies in combined staging CT examinations using a fast-speed acquisition dual-source CT protocol.

    Science.gov (United States)

    Braun, Franziska M; Holzner, Veronica; Meinel, Felix G; Armbruster, Marco; Brandlhuber, Martina; Ertl-Wagner, Birgit; Sommer, Wieland H

    2017-12-01

    To demonstrate the feasibility of fast Dual-Source CT (DSCT) and to evaluate the clinical utility in chest/abdomen/pelvis staging CT studies. 45 cancer patients with two follow-up combined chest/abdomen/pelvis staging CT examinations (maximally ±10 kV difference in tube potential) were included. The first scan had to be performed with our standard protocol (fixed pitch 0.6), the second one using a novel fast-speed DSCT protocol (fixed pitch 1.55). Effective doses (ED) were calculated, noise measurements performed. Scan times were compared, motion artefacts and the diagnostic confidence rated in consensus reading. ED for the standard and fast-speed scans was 9.1 (7.0-11.1) mSv and 9.2 (7.4-12.8) mSv, respectively (P = 0.075). Image noise was comparable (abdomen; all P > 0.05) or reduced for fast-speed CTs (trachea, P = 0.001; ascending aorta, P CT examinations is performed within 2 seconds scan time and eliminates relevant intrathoracic motion/breathing artefacts. Mediastinal/pulmonary pathologies can thus be assessed with high diagnostic confidence. Abdominal image quality remains excellent. • Fast dual-source CT provides chest/abdomen/pelvis staging examinations within 2 seconds scan time. • The sevenfold scan time reduction eliminates relevant intrathoracic motion/breathing artefacts. • Mediastinal/pulmonary pathologies can now be assessed with high diagnostic confidence. • The coverage of the peripheral soft tissues is comparable to single-source CT. • Fast and large-volume oncologic DSCT can be performed with 9 mSv effective dose.

  11. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is an x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  12. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  13. Comparing subjective and objective image quality at two different radiation exposure ranges of the paranasal sinus CT examinations using a volumetric 320-row detector CT system.

    Science.gov (United States)

    Pirimoglu, Berhan; Sade, Recep; Sakat, Muhammed Sedat; Ogul, Hayri; Eren, Suat; Kantarci, Mecit

    2017-12-01

    To evaluate image quality of protocol including 135 kVp, 5 mAs and 80 kVp, 5 mAs in the paranasal sinus CT examinations using single volumetric 320-row multidetector CT technique. From September to December 2016, both of our control group including 135 kVp and 5 mAs and our study group including 80 kVp and 5 mAs paranasal CT protocols were simultaneously performed on 40 patients using single volumetric 320-row multidetector CT device. Image quality for bony structures, air-filled structures and soft tissues were independently assessed for each group by three blinded observers using a 3-point grading scale (0 = not diagnostic, 1 = partially diagnostic, 2 = diagnostic). Objective image quality was also performed by region of interests were placed on axial soft tissue reconstructions in both eye bulbs, retrobulbar fat and maxillary sinuses to obtain different values for aqueous tissue, soft tissue and air, respectively. Effective dose was calculated from the dose-length product. The effective radiation dose which calculated for the control group scans was 0.037 ± 0.003 mSv. But, it was 0.0099 ± 0.001 mSv for the study group scans. The effective radiation dose of study group was statistically significant lower than control group (p doses, image qualities were sufficient for evaluating all the bony structures, air-filled structures and soft tissues except for eye muscle, retrobulbar fat and eye bulb. Our results present that our protocols for study and control group provide significant dose reduction without the loss of diagnostic image quality for paranasal sinus CT. Paranasal sinus CT imaging can be performed at very low radiation exposure maintaining high image quality using a single volume 320-row detector CT device using 135 kVp and 5 mAs.

  14. Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, Marcus; Hack, Nicolas; Hahn, Klaus; Tiling, Reinhold; Jakobs, Tobias; Nikolaou, Konstantin; Becker, Christoph; Reiser, Maximilian; Ziegler, Franz von; Knez, Andreas; Koenig, Andreas; Klauss, Volker

    2007-01-01

    The aim of this study was to evaluate spiral multidetector computed tomography (MDCT) angiography using 64-slice technique in the detection of functionally relevant coronary artery stenoses (CAS). Thirty-eight patients (62±11 years, 28 men) with stable angina (26 with suspected and 12 with known coronary artery disease) were investigated using 64-slice MDCT angiography and gated myocardial perfusion SPECT (gated SPECT); a subgroup of 30 patients had additional invasive coronary angiography (ICA). Stenoses with luminal narrowing of ≥50% were defined as ''significant'' in MDCT angiography and ICA. MDCT angiography was compared with gated SPECT and the combination of gated SPECT plus ICA with respect to the detection of functionally relevant CAS. The sensitivity, specificity and negative and positive predictive values of MDCT angiography in detecting reversible perfusion defects on gated SPECT were 63%, 80%, 94% and 32%, respectively, in vessel-based analysis and 71%, 62%, 72% and 60%, respectively, in patient-based analysis. If only reversible perfusion defects on gated SPECT with CAS ≥50% on ICA were considered, the sensitivity, specificity and negative and positive predictive values were, respectively, 85%, 79%, 98% and 33% for vessel-based analysis and 85%, 59%, 83% and 61% for patient-based analysis. Sixty-four slice MDCT angiography failed to predict the functional relevance of CAS, but had a high negative predictive value in the exclusion of functionally relevant CAS in symptomatic patients. (orig.)

  15. Organ dose measurement using Optically Stimulated Luminescence Detector (OSLD) during CT examination

    Science.gov (United States)

    Yusuf, Muhammad; Alothmany, Nazeeh; Abdulrahman Kinsara, Abdulraheem

    2017-10-01

    This study provides detailed information regarding the imaging doses to patient radiosensitive organs from a kilovoltage computed tomography (CT) scan procedure using OSLD. The study reports discrepancies between the measured dose and the calculated dose from the ImPACT scan, as well as a comparison with the dose from a chest X-ray radiography procedure. OSLDs were inserted in several organs, including the brain, eyes, thyroid, lung, heart, spinal cord, breast, spleen, stomach, liver and ovaries, of the RANDO phantom. Standard clinical scanning protocols were used for each individual site, including the brain, thyroid, lung, breast, stomach, liver and ovaries. The measured absorbed doses were then compared with the simulated dose obtained from the ImPACT scan. Additionally, the equivalent doses for each organ were calculated and compared with the dose from a chest X-ray radiography procedure. Absorbed organ doses measured by OSLD in the RANDO phantom of up to 17 mGy depend on the organ scanned and the scanning protocols used. A maximum 9.82% difference was observed between the target organ dose measured by OSLD and the results from the ImPACT scan. The maximum equivalent organ dose measured during this experiment was equal to 99.899 times the equivalent dose from a chest X-ray radiography procedure. The discrepancies between the measured dose with the OSLD and the calculated dose from the ImPACT scan were within 10%. This report recommends the use of OSLD for measuring the absorbed organ dose during CT examination.

  16. Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system in 133 patients

    International Nuclear Information System (INIS)

    Delhaye, Damien; Remy-Jardin, Martine; Salem, Randa; Teisseire, Antoine; Khalil, Chadi; Remy, Jacques; Delannoy-Deken, Valerie; Duhamel, Alain

    2007-01-01

    To evaluate image quality in the assessment of the coronary arteries during routine ECG-gated multidetector CT (MDCT) of the chest. One hundred and thirty three patients in sinus rhythm underwent an ECG-gated CT angiographic examination of the entire chest without β-blockers with a 64-slice CT system. In 127 patients (95%), it was possible to assess the coronary arteries partially or totally; coronary artery imaging failed in six patients (5%), leading to a detailed description of the coronary arteries in 127 patients. Considering ten coronary artery segments per patient, 75% of coronary segments were assessable (948/1270 segments). When the distal segments were excluded from the analysis (i.e., seven coronary segments evaluated per patient), the percentage of assessable segments was 86% (768/889 proximal and mid coronary segments) and reached 93% (474/508) when assessing proximal segments exclusively. The mean number of assessable segments was significantly higher in patients with a heart rate ≤80 bpm (n=95) than in patients with a heart rate >80 bpm (n=38) (p<0.002). Proximal and mid-coronary segments can be adequately assessed during a whole-chest ECG-gated CT angiographic examination without administration of β-blockers in patients with a heart rate below 80 bpm. (orig.)

  17. A minimally interactive method to segment enlarged lymph nodes in 3D thoracic CT images using a rotatable spiral-scanning technique

    Science.gov (United States)

    Wang, Lei; Moltz, Jan H.; Bornemann, Lars; Hahn, Horst K.

    2012-03-01

    Precise size measurement of enlarged lymph nodes is a significant indicator for diagnosing malignancy, follow-up and therapy monitoring of cancer diseases. The presence of diverse sizes and shapes, inhomogeneous enhancement and the adjacency to neighboring structures with similar intensities, make the segmentation task challenging. We present a semi-automatic approach requiring minimal user interactions to fast and robustly segment the enlarged lymph nodes. First, a stroke approximating the largest diameter of a specific lymph node is drawn manually from which a volume of interest (VOI) is determined. Second, Based on the statistical analysis of the intensities on the dilated stroke area, a region growing procedure is utilized within the VOI to create an initial segmentation of the target lymph node. Third, a rotatable spiral-scanning technique is proposed to resample the 3D boundary surface of the lymph node to a 2D boundary contour in a transformed polar image. The boundary contour is found by seeking the optimal path in 2D polar image with dynamic programming algorithm and eventually transformed back to 3D. Ultimately, the boundary surface of the lymph node is determined using an interpolation scheme followed by post-processing steps. To test the robustness and efficiency of our method, a quantitative evaluation was conducted with a dataset of 315 lymph nodes acquired from 79 patients with lymphoma and melanoma. Compared to the reference segmentations, an average Dice coefficient of 0.88 with a standard deviation of 0.08, and an average absolute surface distance of 0.54mm with a standard deviation of 0.48mm, were achieved.

  18. Multi-slice spiral CT in routine diagnosis of suspected acute left-sided colonic diverticulitis: a prospective study of 120 patients

    International Nuclear Information System (INIS)

    Werner, A.; Diehl, S.J.; Dueber, C.; Farag-Soliman, M.

    2003-01-01

    This prospective study evaluated the use of multi-slice CT (MSCT) for detection of clinically suspected left-sided colonic diverticulitis with regard to diagnosis, complications and alternative diagnoses. One hundred twenty patients with clinically suspected acute left-colonic diverticulitis underwent MSCT of the lower abdomen with IV contrast after rectal application of iodic contrast. The MSCT results were compared with histopathological and intraoperative findings or other radiological or endoscopic methods and clinical outcome. Acute diverticulitis was proven in 67 of the 120 (55.8%) patients, which was detected by MSCT with an accuracy of 98% (sensitivity 97%, specificity 98%). Contained perforation or abscess formation were detected with an accuracy of 96% (sensitivity 100%, specificity 91%) and 98% (sensitivity 100%, specificity 97%), respectively. In 31 of 120 (25.8%) patients diagnoses other than diverticulitis caused abdominal pain, which was correctly diagnosed by MSCT in 71%. The MSCT as well as other concurrently performed diagnostic methods showed normal findings and no causes for the patients symptoms in 22 of the 120 (18.4%) patients. Multi-slice CT is reliable in detecting diverticulitis, including extracolic complications, and often reveals other diagnoses; therefore, MSCT is recommended as standard diagnostic procedure in suspected acute diverticulitis. (orig.)

  19. Multi-slice spiral CT in routine diagnosis of suspected acute left-sided colonic diverticulitis: a prospective study of 120 patients

    Energy Technology Data Exchange (ETDEWEB)

    Werner, A.; Diehl, S.J.; Dueber, C. [Institut fuer Klinische Radiologie, Universitaetsklinikum Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim (Germany); Farag-Soliman, M. [Chirurgische Klinik, Universitaetsklinikum Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim (Germany)

    2003-12-01

    This prospective study evaluated the use of multi-slice CT (MSCT) for detection of clinically suspected left-sided colonic diverticulitis with regard to diagnosis, complications and alternative diagnoses. One hundred twenty patients with clinically suspected acute left-colonic diverticulitis underwent MSCT of the lower abdomen with IV contrast after rectal application of iodic contrast. The MSCT results were compared with histopathological and intraoperative findings or other radiological or endoscopic methods and clinical outcome. Acute diverticulitis was proven in 67 of the 120 (55.8%) patients, which was detected by MSCT with an accuracy of 98% (sensitivity 97%, specificity 98%). Contained perforation or abscess formation were detected with an accuracy of 96% (sensitivity 100%, specificity 91%) and 98% (sensitivity 100%, specificity 97%), respectively. In 31 of 120 (25.8%) patients diagnoses other than diverticulitis caused abdominal pain, which was correctly diagnosed by MSCT in 71%. The MSCT as well as other concurrently performed diagnostic methods showed normal findings and no causes for the patients symptoms in 22 of the 120 (18.4%) patients. Multi-slice CT is reliable in detecting diverticulitis, including extracolic complications, and often reveals other diagnoses; therefore, MSCT is recommended as standard diagnostic procedure in suspected acute diverticulitis. (orig.)

  20. The possibility of application of spiral brain computed tomography to traumatic brain injury.

    Science.gov (United States)

    Lim, Daesung; Lee, Soo Hoon; Kim, Dong Hoon; Choi, Dae Seub; Hong, Hoon Pyo; Kang, Changwoo; Jeong, Jin Hee; Kim, Seong Chun; Kang, Tae-Sin

    2014-09-01

    The spiral computed tomography (CT) with the advantage of low radiation dose, shorter test time required, and its multidimensional reconstruction is accepted as an essential diagnostic method for evaluating the degree of injury in severe trauma patients and establishment of therapeutic plans. However, conventional sequential CT is preferred for the evaluation of traumatic brain injury (TBI) over spiral CT due to image noise and artifact. We aimed to compare the diagnostic power of spiral facial CT for TBI to that of conventional sequential brain CT. We evaluated retrospectively the images of 315 traumatized patients who underwent both brain CT and facial CT simultaneously. The hemorrhagic traumatic brain injuries such as epidural hemorrhage, subdural hemorrhage, subarachnoid hemorrhage, and contusional hemorrhage were evaluated in both images. Statistics were performed using Cohen's κ to compare the agreement between 2 imaging modalities and sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT to conventional sequential brain CT. Almost perfect agreement was noted regarding hemorrhagic traumatic brain injuries between spiral facial CT and conventional sequential brain CT (Cohen's κ coefficient, 0.912). To conventional sequential brain CT, sensitivity, specificity, positive predictive value, and negative predictive value of spiral facial CT were 92.2%, 98.1%, 95.9%, and 96.3%, respectively. In TBI, the diagnostic power of spiral facial CT was equal to that of conventional sequential brain CT. Therefore, expanded spiral facial CT covering whole frontal lobe can be applied to evaluate TBI in the future. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Updated estimates of typical effective doses for common CT examinations in the UK following the 2011 national review.

    Science.gov (United States)

    Shrimpton, Paul C; Jansen, Jan T M; Harrison, John D

    2016-01-01

    To investigate the impact of evolving International Commission on Radiological Protection (ICRP) recommendations concerning calculation of effective dose (E) and compare updated typical UK values for common CT examinations with previous data. Monte Carlo simulations have provided normalized organ doses relating to 15 CT scanner models and 5 virtual reference adults. Series of representative E/dose-length product (DLP) coefficients were derived for common examinations on the separate bases of not only older stylized mathematical phantoms and voxel phantoms presently recommended by ICRP, but also the 1977, 1990 and 2007 formulations for E. Updated E/DLP coefficients were applied to typical values of DLP from the 2011 UK survey. Changes in ICRP recommendations that have arisen from improving evidence on stochastic risk, influence values of E by up to a factor two for CT examinations of the head and neck, although differences for the trunk typically amount to ±10%. Adoption of the voxel rather than the mathematical phantoms used previously can lead to further changes in E by a few tens of percent. Updated typical values of E for UK CT examinations range from 2 to 20 mSv. Increases by 20-400% since 2003 arise not only from increases by 30-160% in typical values of DLP, but also increases by 30-90% in relation to E/DLP coefficients for examinations of the trunk. Values of E, including updated typical data for UK CT, should be compared with caution in relation to their purpose and underlying factors concerning their calculation. Updated E/DLP coefficients and typical values of E for UK CT, and an appreciation of factors influencing these data.

  2. The possibilities of spiral computed tomography in evaluating of pathologic changes of the inner surface of the stomach

    International Nuclear Information System (INIS)

    Pomakov, P.; Mlachkova, D.; Naraliev, V.; Lyutckanova, E.

    2006-01-01

    Full text: The aim of the presentation is to determine the possibilities of spiral CT for evaluating pathologic changes, affecting predominantly the stomach mucosa. 20 patients with preliminary clinical diagnosis 'cancer of the stomach' were examined. The patients had different complaints. Gas CT with medical myorelaxation of the stomach was performed. The stomach cavity was inflated by swallowing of three effervescent tablets vitamin C 500 mg with a little water. After the native CT examination a contrast series was performed 20 min. after the beginning of injecting 100 ml nonionic contrast in the arterial phase. 16 patients had no pathologic changes in the stomach. In the rest were established: lymphoma of the stomach - in 1 patient, carcinoma stage I - 1, polyps - 1, erritemoerosive gastritis - 1. CT findings were compared with the histologic ones. Gas CT in arterial contrast phase has possibilities for evaluating changes, affecting predominantly the inner surface (mucosa) of the stomach

  3. Three-dimensional CT examination of the mastication system in the giant anteater.

    Science.gov (United States)

    Endo, Hideki; Niizawa, Nobuharu; Komiya, Teruyuki; Kawada, Shinichiro; Kimura, Junpei; Itou, Takuya; Koie, Hiroshi; Sakai, Takeo

    2007-10-01

    The gross anatomy of the mastication system of the giant anteater (Myrmecophaga tridactyla) was examined by means of three-dimensional image analysis. The anteater rotates the mandibles medially and laterally to control its tongue when it is elongated and to house it when it is relaxed. Three-dimensional CT image analysis demonstrated that the shape and size of the oral cavity changes drastically when the mandibles are rotated. The oral cavity expands bilaterally when the dorsal part of the mandibles bend medially. Macroscopic observations and muscle-weight data supported the observation that the superficial temporal and medial pterygoid muscles act as the main medial and lateral rotators of the mandible, respectively. The low height of the mandibular ramus and the incomplete zygomatic arch in this species represent adaptations for the rotational movement of the mandibles, since they both contribute to the medially oriented transmission of force from the temporal muscles and to preventing collision between the mandibles and the cranium during the rotational movement.

  4. Estimates of effective dose in adult CT examinations using toshiba and Siemens 16 slice scanner in some Khartoum hospitals

    International Nuclear Information System (INIS)

    Mohamed, Suhair Ahmed Al Amin

    2015-08-01

    The aim of this work was to evaluate effective dose (E) in adult CT examinations for toshiba and Siemens 16 slice using CT. Exp version 2.5 software. using of CT in medical diagnosis delivers effective dose (E) to patients which are relatively high in comparison with those of other diagnostic radiology procedures. In order to achieve these objectives, data of CT scanner has been collected from two hospitals (RUH and YH). Data collected included equipment information and scan parameters for individual patients, who were used to assess dose. 252 adult patients underwent head, sinus, abdomen, pelvis and CTU CT examinations. The CTDI w , CTDI v ol, DLP, patient effective dose and organ doses were evaluated, using CT exposure parameters and CT Exp version 2.5 software. A large variation of mean effective dose and organ doses among hospitals was observed for similar CT examinations. These variations largely originated from different CT scanning manufacture and protocols used in different hospitals and scan length. The mean effective dose in this study in the brain, PNS, abdomen, pelvis, and CTU were 3.02 mSv, 0.97 mSv, 5.58 mSv, 3.36 mSv and 15.88 mSv respectively, and organ equivalent doses presented in this study for the eye lens (for head), lungs and thymus, liver, kidney and small intestine (for abdomen), bladder, uterus and gonads (for pelvis), were 62.9 mSv, 39.5 mSv, 34.1 mSv, 35.4 mSv, 53.9 mSv, 52.6 mSv, 58.1 mSv, 37 mSv, and 34.6 mSv, respectively. These values were more mostly comparable to and slightly higher than the values of effective doses reported from similar studies the United Kingdom, Western Australia, Iran and Sudan. It was concluded that patient effective dose and organ doses could be substantially minimized through careful selection of scanning parameters based on clinical indications of study, patient size, and body region being examined. Additional dose reduction to superficial organs would require the use of shielding materials. (Author)

  5. Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination

    Science.gov (United States)

    Zeigler, R. A.; Righter, K.; Allen, C. C.

    2013-01-01

    An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of the PET is to characterize and classify returned samples and make this information available to the larger research community who then conduct more in-depth studies on the samples. The PET tries to minimize the impact their work has on the sample suite, which has in the past limited the PET work to largely visual, nonquantitative measurements (e.g., optical microscopy). More modern techniques can also be utilized by a PET to nondestructively characterize astromaterials in much more rigorous way. Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET. Results: The application of micro computerized tomography (micro-CT) to astromaterials is not a new concept. The technique involves scanning samples with high-energy x-rays and constructing 3-dimensional images of the density of materials within the sample. The technique can routinely measure large samples (up to approx. 2700 cu cm) with a small individual voxel size (approx. 30 cu m), and has the sensitivity to distinguish the major rock forming minerals and identify clast populations within brecciated samples. We have recently run a test sample of a terrestrial breccia with a carbonate matrix and multiple igneous clast lithologies. The test results are promising and we will soon analyze a approx. 600 g piece of Apollo sample 14321 to map out the clast population within the sample. Benchtop micro x-ray fluorescence (micro-XRF) instruments can rapidly scan large areas (approx. 100 sq cm) with a small pixel size (approx. 25 microns) and measure the (semi) quantitative composition of largely unprepared surfaces for all elements between Be and U, often with sensitivity on the order of a approx. 100 ppm. Our recent

  6. Non-trauma-associated additional findings in whole-body CT examinations in patients with multiple trauma

    International Nuclear Information System (INIS)

    Hoffstetter, P.; Herold, T.; Daneschnejad, M.; Zorger, N.; Jung, E.M.; Feuerbach, S.; Schreyer, A.G.

    2008-01-01

    Purpose: whole-body CT scans for patients with multiple trauma represent an increasingly accepted first diagnostic tool. The multidetector approach in particular provides appropriate diagnostic algorithms for detecting nearly all relevant traumatic findings in a short time with a high grade of sensitivity and specificity. Non-trauma-associated additional findings are commonly depicted based on these CT examinations. The aim of this study is to evaluate the number and quality of these additional findings in consecutive patients with multiple trauma. Materials and methods: between 3/04 and 8/06 we scanned 304 patients according to our dedicated multiple trauma protocol. The examination protocol includes a head scan without intravenous contrast followed by a whole-body scan including the neck, thorax and abdomen acquired by a 16-row CT Scanner (Siemens, Sensation 16). The CT scans were retrospectively analyzed by two radiologists with respect to non-trauma-associated findings. Lesions were assessed according to their clinical relevance (highly relevant, moderately relevant, not relevant). For patients with highly relevant findings, additional follow-up research was performed. Results: The average age was 43 years (range 3 - 92). 236 of the patients were male (77.6%), 68 female (22.4%). 153 patients (50.3%) had additional non-trauma-associated findings. In 20 cases (6.6%) lesions with high clinical relevance were detected (e.g. carcinoma of the kidney or the ovary). In 71 patients (23.4%) findings with moderate relevance were described. In 63 patients (20.7%) additional findings without major relevance were diagnosed. Conclusion: Whole-body CT scans of patients randomized by a trauma show a considerable number of non-trauma-associated additional findings. In about 30% of cases, these findings are clinically relevant because further diagnostic workup or treatment in the short or medium-term is needed. The results of these analyses emphasize the diagnostic value of CT

  7. [The clinical application of gene chips combined with CT examination in the diagnosis of large vestibular aqueduct syndrome patients].

    Science.gov (United States)

    Zhou, Feng; Lin, Ying; Luo, Qiong; Chen, Xiaoke; Huang, Lifen; Liang, Zijian; Wang, Haitao; Yu, Feng

    2013-10-01

    To explore the feasibility and superiority of the gene chip method and temporal bone CT in diagnosis of large vestibular aqueduct syndrome. One hundred and eighty-eight cases of deaf students in Guangzhou were selected,the microarray detection of the SLC26A4 gene locus was performed,and the 26 cases of students with detected SLC26A4 gene mutations received temporal bone CT imaging. Among the detected 26 cases of patients with hearing loss, IVS7-2A>G homozygous mutation was found in 7 cases, 17 cases were heterozygous mutation, 2168A>G heterozygous mutation presented in three cases, including one case of IVS7-2A>G and 2168A>G compound heterozygous mutations. Temporal bone CT findings of 25 cases among the 26 patients showed bilateral large vestibular aqueduct,among which 9 cases exhibited bilateral cochlear malformations, and 1 case was normal. Among the different SLC26A4 gene mutations, IVS7-2A>G point mutation rates the highest, followed by 2168A>G. Most of the CT examination prompted the expansion of the vestibular aqueduct. Deafness gene chip hotspot detection of SLC26A4 gene mutations can diagnose such patients before CT examination,which can be used for screening people with high risk of deafness prenatal screening. The early detection and early diagnosis can guide proper precautionary measures in advance to prevent the occurrence of prelingual deafness.

  8. Association between the mean CT value on a scout view and the dependent mA selection method in coronary artery imaging on 64-row multi-slice spiral CT

    International Nuclear Information System (INIS)

    Gao Jianhua; Li Tao; Mi Fengtang; Li Na; Cui Ying; Dai Ruping; Li Jianying

    2009-01-01

    Objective: To characterize the association between the mean CT value on a scout view and the dependent mA selection method, and to evaluate the clinical value of a mA selection method based on scout view mean CT value in obtaining individualized scan protocol and consistent image quality for patient population on 64-row MSCT CT coronary angiography (CTCA). Methods: One hundred patients (group A) underwent CTCA consecutively using standard protocol with a fixed mA. The mean CT value of a fixed ROI (region of interest) from the scout AP view and the CTCA image noise (standard deviation on the root of ascending aorta) were measured. The correlation between CT values and noise was studied to establish a formula and a list to determine the required mA for obtaining a consistent CTCA image noise based on the measured SV CT value. Another 100 patients (group B) were scanned using the same parameters as group A except the mA and the CT value was also measured. The mA was determined by the list established previously. The CTCA image quality (IQ) as well as the image noise (IN) and the effective dose (ED) from the two groups were statistically analyzed using t-test. The CT findings for the 32 patients in the group B were also compared with the selective coronary angiography (SCA) results. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of CTCA for detection of significant stenosis were obtained. Results: The formula between the required mA and the CT value was: XmA=FmA x [(K 1 x CTscout + C 1 )/INa] 2 . The CTCA images in B group had statistically higher IN (27.66±2.57, 22.22±4.17, t=11.33, P=0.000), but no statistical difference between IQ scores for the two groups (3.29±0.66, 3.37±0.67, t=0.009, P=0.990), and ED [(8.72±2.51) versus (12.53±0.90) mSv] was 30% lower for the B group (P<0.01). For the 32 patients in the B group who had SCA, the CTCA sensitivity, specificity, positive predictive value, negative

  9. Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey.

    Science.gov (United States)

    Ekpo, Ernest U; Adejoh, Thomas; Akwo, Judith D; Emeka, Owujekwe C; Modu, Ali A; Abba, Mohammed; Adesina, Kudirat A; Omiyi, David O; Chiegwu, Uche H

    2018-01-29

    To explore doses from common adult computed tomography (CT) examinations and propose national diagnostic reference levels (nDRLs) for Nigeria. This retrospective study was approved by the Nnamdi Azikiwe University and University Teaching Hospital Institutional Review Boards (IRB: NAUTH/CS/66/Vol8/84) and involved dose surveys of adult CT examinations across the six geographical regions of Nigeria and Abuja from January 2016 to August 2017. Dose data of adult head, chest and abdomen/pelvis CT examinations were extracted from patient folders. The median, 75th and 25th percentile CT dose index volume (CTDI vol ) and dose-length-product (DLP) were computed for each of these procedures. Effective doses (E) for these examinations were estimated using the k conversion factor as described in the ICRP publication 103 (E DLP  =  k × DLP ). The proposed 75th percentile CTDI vol for head, chest, and abdomen/pelvis are 61 mGy, 17 mGy, and 20 mGy, respectively. The corresponding DLPs are 1310 mGy.cm, 735 mGy.cm, and 1486 mGy.cm respectively. The effective doses were 2.75 mSv (head), 10.29 mSv (chest), and 22.29 mSv (abdomen/pelvis). Findings demonstrate wide dose variations within and across centres in Nigeria. The results also show CTDI vol comparable to international standards, but considerably higher DLP and effective doses.

  10. Improved assessment of mediastinal and pulmonary pathologies in combined staging CT examinations using a fast-speed acquisition dual-source CT protocol

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Franziska M.; Holzner, Veronica; Meinel, Felix G.; Armbruster, Marco; Brandlhuber, Martina; Ertl-Wagner, Birgit; Sommer, Wieland H. [University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2017-12-15

    To demonstrate the feasibility of fast Dual-Source CT (DSCT) and to evaluate the clinical utility in chest/abdomen/pelvis staging CT studies. 45 cancer patients with two follow-up combined chest/abdomen/pelvis staging CT examinations (maximally ±10 kV difference in tube potential) were included. The first scan had to be performed with our standard protocol (fixed pitch 0.6), the second one using a novel fast-speed DSCT protocol (fixed pitch 1.55). Effective doses (ED) were calculated, noise measurements performed. Scan times were compared, motion artefacts and the diagnostic confidence rated in consensus reading. ED for the standard and fast-speed scans was 9.1 (7.0-11.1) mSv and 9.2 (7.4-12.8) mSv, respectively (P = 0.075). Image noise was comparable (abdomen; all P > 0.05) or reduced for fast-speed CTs (trachea, P = 0.001; ascending aorta, P < 0.001). Motion artefacts of the heart/the ascending aorta (all P < 0.001) and breathing artefacts (P < 0.031) were reduced in fast DSCT. The diagnostic confidence for the evaluation of mediastinal (P < 0.001) and pulmonary (P = 0.008) pathologies was improved for fast DSCT. Fast DSCT for chest/abdomen/pelvis staging CT examinations is performed within 2 seconds scan time and eliminates relevant intrathoracic motion/breathing artefacts. Mediastinal/pulmonary pathologies can thus be assessed with high diagnostic confidence. Abdominal image quality remains excellent. (orig.)

  11. Evaluation of diagnostic reference dose levels in CT- scan examinations of adolescence in Tehran: a brief report

    Directory of Open Access Journals (Sweden)

    Afzalipour R

    2013-05-01

    Full Text Available Background: Today, a CT scan examination play an important role in disease diagnosis and thus allocates a significant dose of medical X-ray examinations. One of the important principles in the use of ionizing radiations is to observe radiation protection principles. Evaluating patient's absorbed dose and implementing the strategies for reducing dose are prior in safety issues. To achieve this purpose, sufficient studies should be performed in this regard. Therefore, patient's absorbed dose and the factors affecting have been studied in this research. This study aims to present and develop an acceptable level of absorbed dose in CT scan examinations.Methods: Diagnostic reference dose level in the adult age group (older than 15 years has been studied in eleven CT scan centers in Tehran. For this purpose, CT scan examinations prevalent in above-mentioned centers were chosen and Weighted Computed Tomography dose index (CTDIw and dose length product (DLP parameters were studied. Standard phantoms with 16 and 32 diameters of Polymethylmethacrylate (PMMA origin have been used in the centers for CT scan calibration process. CTDIw third quartile has been considered as the diagnostic reference dose level (DRL.Results: Rate of diagnostic reference dose in the adult age group (older than 15 years for the head, sinus, lungs, abdomen and pelvis are 50.87, 38.27, 8.05 and 9.11 mg, respectively. Dose measurements made in this survey have been used to set up local DRLs and can be used as a template for national DRLs.Conclusion: Value of diagnostic reference dose for the head examinations is more than the other parts and diagnostic reference dose in Tehran city in the Adult age group and the protocols compared is less than national reference dose.

  12. Incidence of tendon entrapment and dislocation with calcaneus and pilon fractures on CT examination

    Energy Technology Data Exchange (ETDEWEB)

    Tresley, Jonathan [Jackson Memorial Hospital, Department of Diagnostic Radiology, Miami, FL (United States); University of Wisconsin-Madison, Department of Radiology, Madison, WI (United States); Subhawong, Ty K.; Singer, Adam D.; Clifford, Paul D. [Jackson Memorial Hospital, Department of Diagnostic Radiology, Miami, FL (United States)

    2016-07-15

    To examine the association between tibial pilon and calcaneal fracture classification and tendon entrapment or dislocation. After institutional review board approval, we retrospectively reviewed consecutive CT scans with calcaneal or pilon fractures from 5 years at a level 1 trauma center. We categorized calcaneal fractures according to the Sanders classification, and pilon fractures according to the Ruedi and Allgower and the Arbeitsgemeinschaft fuer Osteosynthesefragen-Orthopaedic Trauma Association (AO-OTA) classifications. Ankle tendons were assessed for dislocation or entrapment. Fisher's exact test was used for statistical analysis with significance at p < 0.05. A total of 312 fractures (91 pilon only, 193 calcaneal only, and 14 ankles with ipsilateral pilon and calcaneal fractures) were identified in 273 patients. Twenty-two pilon, 42 calcaneal, and nine combination fractures were associated with 99 occurrences of tendon entrapment or superior peroneal retinacular injury. Such findings were associated with multiple fractures (p = 0.002). Multifragmentary pilon fractures were associated with posterior tibial and flexor digitorum longus tendon entrapment (p < 0.0001 and p = 0.0003 for Ruedi/Allgower and AO-OTA, respectively), and multifragmentary Sanders type 3 or 4 calcaneal fractures were associated with superior peroneal retinacular injury (p = 0.0473) compared to simple fracture patterns. Thirty-nine percent of tendon entrapments or retinacular injuries were prospectively identified, 85 % by musculoskeletal radiologists (p < 0.0001). Approximately 25 % of calcaneal and pilon fractures were retrospectively identified to contain posteromedial tendon entrapment or superior peroneal retinacular injury. Radiologists should meticulously search for such injuries, particularly when analyzing multifragmentary and multiple fractures. (orig.)

  13. Incidence of tendon entrapment and dislocation with calcaneus and pilon fractures on CT examination

    International Nuclear Information System (INIS)

    Tresley, Jonathan; Subhawong, Ty K.; Singer, Adam D.; Clifford, Paul D.

    2016-01-01

    To examine the association between tibial pilon and calcaneal fracture classification and tendon entrapment or dislocation. After institutional review board approval, we retrospectively reviewed consecutive CT scans with calcaneal or pilon fractures from 5 years at a level 1 trauma center. We categorized calcaneal fractures according to the Sanders classification, and pilon fractures according to the Ruedi and Allgower and the Arbeitsgemeinschaft fuer Osteosynthesefragen-Orthopaedic Trauma Association (AO-OTA) classifications. Ankle tendons were assessed for dislocation or entrapment. Fisher's exact test was used for statistical analysis with significance at p < 0.05. A total of 312 fractures (91 pilon only, 193 calcaneal only, and 14 ankles with ipsilateral pilon and calcaneal fractures) were identified in 273 patients. Twenty-two pilon, 42 calcaneal, and nine combination fractures were associated with 99 occurrences of tendon entrapment or superior peroneal retinacular injury. Such findings were associated with multiple fractures (p = 0.002). Multifragmentary pilon fractures were associated with posterior tibial and flexor digitorum longus tendon entrapment (p < 0.0001 and p = 0.0003 for Ruedi/Allgower and AO-OTA, respectively), and multifragmentary Sanders type 3 or 4 calcaneal fractures were associated with superior peroneal retinacular injury (p = 0.0473) compared to simple fracture patterns. Thirty-nine percent of tendon entrapments or retinacular injuries were prospectively identified, 85 % by musculoskeletal radiologists (p < 0.0001). Approximately 25 % of calcaneal and pilon fractures were retrospectively identified to contain posteromedial tendon entrapment or superior peroneal retinacular injury. Radiologists should meticulously search for such injuries, particularly when analyzing multifragmentary and multiple fractures. (orig.)

  14. Discrepancy between absorbed dose estimated from phantom measurements and from estimates using data on individual head sizes in head CT examinations.

    Science.gov (United States)

    Adliene, D; Mockeviciene, S

    2010-01-01

    Patient doses during computed tomography (CT) scanning are relative high, as compared with doses received by patients during conventional X-ray examinations. Owing to this, every possible optimisation of CT examinations is of importance. Dose estimation in CT examinations of patients are normally based on measurements of CT dose index and dose length products in standardised CT phantoms, representing a standard person of 70 kg. Real patients may differ significantly from this standard, and hence the dose values calculated for a phantom are not relevant for the individual patient. In this investigation, the effective dose for 31 patients undergoing a CT examination of their head has been evaluated using measurements on a standard CT head phantom and the data corrected for the real size (perimeter) and exposed volume of the patient's head. It is shown that the actual doses to patients were higher in 50 % cases of all performed head CT examinations, compared with doses estimated from phantom measurements. A dose calculation model for head CT patients based on the individual patient's head size (perimeter) and exposed head volume is proposed and the possibility to optimise head CT examinations of patients is discussed.

  15. Triangular spiral tilings

    International Nuclear Information System (INIS)

    Sushida, Takamichi; Hizume, Akio; Yamagishi, Yoshikazu

    2012-01-01

    The topology of spiral tilings is intimately related to phyllotaxis theory and continued fractions. A quadrilateral spiral tiling is determined by a suitable chosen triple (ζ, m, n), where ζ element of D/R, and m and n are relatively prime integers. We give a simple characterization when (ζ, m, n) produce a triangular spiral tiling. When m and n are fixed, the admissible generators ζ form a curve in the unit disk. The family of triangular spiral tilings with opposed parastichy pairs (m, n) is parameterized by the divergence angle arg (ζ), while triangular spiral tilings with non-opposed parastichy pairs are parameterized by the plastochrone ratio 1/|ζ|. The generators for triangular spiral tilings with opposed parastichy pairs are not dense in the complex parameter space, while those with non-opposed parastichy pairs are dense. The proofs will be given in a general setting of spiral multiple tilings. We present paper-folding (origami) sheets that build spiral towers whose top-down views are triangular tilings. (paper)

  16. Evaluation of shielding capability of controlled area for CT examination room

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Asada, Yasuki; Nakai, Takayo; Takeuchi, Kichito; Kinoshita, Kazuo; Watanabe, Nobuyuki; Koga, Sukehiko

    2002-01-01

    With the revision of the law in April, 2001, the effective dose at the boundary of the controlled area was set at 1.3 mSv/3M. Whether the shielding capability of the CT room satisfied the provisions of the law or not was confirmed by actual measurements. Both thermo luminescence dosemeter (TLD) and electronic dosemeter were used to measure the radiation doses. The shielding capability of the gantry was studied both inside and outside the room for a week as a basic experiment. On the basis of the data thus obtained doses accumulated in 3 months were estimated. According to the results of 3 month-measurement, the doses outside the wall of the CT room were about 200μ Sv. This numerical value was comparable to the background level of the evaluation point. The results above assured that the shielding capability of the CT room satisfied the provisions of the law well. (author)

  17. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Matsumoto, Tomohiro; Hasebe, Terumitsu [Tokai University Hachioji Hospital, Tokai University School of Medicine, Department of Radiology, Hachioji, Tokyo (Japan); Kakizawa, Hideaki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Hiroshima Red Cross Hospital and Atomic-bomb Survivors Hospital, Department of Diagnostic Radiology, Naka-Ku, Hiroshima (Japan); Toyoda, Naoyuki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); National Hospital Organisation Kure Medical Centre, Department of Diagnostic Radiology, Kure, Hiroshima (Japan)

    2014-05-15

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  18. CT examinations to age and sex depended variations of intracranial structures

    International Nuclear Information System (INIS)

    Tellkamp, H. v.; Rosenkranz, G.; Koehler, K.

    1986-01-01

    This paper supplies proof of the age dependence of the physiological cerebral density and ventricle size. The studies are based on the evaluation of normal cerebral computer tomograms of a total of 1100 patients of both sexes. Mathematical statistical calculations yield accurate data on the age-conditioned physiological 'standard ranges' of cerebral density and ventricle width (3rd and 4th ventricle). By means of the graphic representations and calculation formulas it is possible to achieve rapid orientation provided the CT technique employed is the same. The results as communicated in this paper enable further quantification and objectivation of our CT data. (orig.) [de

  19. Do physical examination and CT-scan measures of femoral neck anteversion and tibial torsion relate to each other?

    Science.gov (United States)

    Sangeux, Morgan; Mahy, Jessica; Graham, H Kerr

    2014-01-01

    Informed clinical decision making for femoral and/or tibial de-rotation osteotomies requires accurate measurement of patient function through gait analysis and anatomy through physical examination of bony torsions. Validity of gait analysis has been extensively studied; however, controversy remains regarding the accuracy of physical examination measurements of femoral and tibial torsion. Comparison between CT-scans and physical examination measurements of femoral neck anteversion (FNA) and external tibial torsion (ETT) were retrospectively obtained for 98 (FNA) and 64 (ETT) patients who attended a tertiary hospital for instrumented gait analysis between 2007 and 2010. The physical examination methods studied for femoral neck anteversion were the trochanteric prominence angle test (TPAT) and the maximum hip rotation arc midpoint (Arc midpoint) and for external tibial torsion the transmalleolar axis (TMA). Results showed that all physical examination measurements statistically differed to the CT-scans (bias(standard deviation): -2(14) for TPAT, -10(12) for Arc midpoint and -16(9) for TMA). Bland and Altman plots showed that method disagreements increased with increasing bony torsions in all cases but notably for TPAT. Regression analysis showed that only TMA and CT-scan measurement of external tibial torsion demonstrated good (R(2)=57%) correlation. Correlations for both TPAT (R(2)=14%) and Arc midpoint (R(2)=39%) with CT-scan measurements of FNA were limited. We conclude that physical examination should be considered as screening techniques rather than definitive measurement methods for FNA and ETT. Further research is required to develop more accurate measurement methods to accompany instrumented gait analysis. Copyright © 2013. Published by Elsevier B.V.

  20. A practical approach to radiological evaluation of CT lung cancer screening examinations

    NARCIS (Netherlands)

    Xie, Xueqian; Heuvelmans, Marjolein A.; van Ooijen, Peter M. A.; Oudkerk, Matthijs; Vliegenthart, Rozemarijn

    2013-01-01

    Lung cancer is the most common cause of cancer-related death in the world. The Dutch-Belgian Randomized Lung Cancer Screening Trial (Dutch acronym: NELSON) was launched to investigate whether screening for lung cancer by low-dose multidetector computed tomography (CT) in high-risk patients will lead

  1. Spiral Countercurrent Chromatography

    Science.gov (United States)

    Ito, Yoichiro; Knight, Martha; Finn, Thomas M.

    2013-01-01

    For many years, high-speed countercurrent chromatography conducted in open tubing coils has been widely used for the separation of natural and synthetic compounds. In this method, the retention of the stationary phase is solely provided by the Archimedean screw effect by rotating the coiled column in the centrifugal force field. However, the system fails to retain enough of the stationary phase for polar solvent systems such as the aqueous–aqueous polymer phase systems. To address this problem, the geometry of the coiled channel was modified to a spiral configuration so that the system could utilize the radially acting centrifugal force. This successfully improved the retention of the stationary phase. Two different types of spiral columns were fabricated: the spiral disk assembly, made by stacking multiple plastic disks with single or four interwoven spiral channels connected in series, and the spiral tube assembly, made by inserting the tetrafluoroethylene tubing into a spiral frame (spiral tube support). The capabilities of these column assemblies were successfully demonstrated by separations of peptides and proteins with polar two-phase solvent systems whose stationary phases had not been well retained in the earlier multilayer coil separation column for high-speed countercurrent chromatography. PMID:23833207

  2. Establishment of a comprehensive set of regional DRLs for CT by means of electronic X-ray examination records.

    Science.gov (United States)

    Charnock, P; Dunn, A F; Moores, B M; Murphy, J; Wilde, R

    2015-03-01

    The International Commission on Radiological Protection (ICRP) has indicated that the diagnostic reference level (DRL) has the optimisation of protection as its objective for diagnostic and interventional procedures [International Commission on Radiological Protection. Protection against ionising radiation from external sources: ICRP Report 105 (2007)]. An important aim of this paper was to demonstrate a straightforward and cost-effective mechanism for undertaking patient dose audits that can be employed in the production of local and regional DRLs for use by medical physics experts in the provision of scientific support services to diagnostic radiology. The process developed employs electronic X-ray examination records obtained from multiple hospital sites transferred to a central processing and reporting facility. Results of a large-scale audit of patient doses resulting from CT examinations are presented. Doses are expressed in terms of dose length product (DLP) and were collected by remotely accessing electronic examination records held in hospital radiology information systems. Data were collected from 18 hospital sites involving up to 123 different types of examinations covering an ∼18-month period from July 2011 to December 2012. In total, 177 000 CT examination records were collected. Values have been validated against equivalent records obtained from digital imaging and communications in medicine (DICOM) header data and found to be in excellent statistical agreement. Extremely large variations in DLP values were noted for many examinations when data for all scanners were pooled. Results are discussed in relation to other surveys and differences highlighted in terms of the variations in methodologies employed and the numbers of examination records investigated. A mechanism for establishing DRLs is proposed, which could help to unify mechanisms for establishing DRLs for CT examinations. © The Author 2014. Published by Oxford University Press. All rights

  3. A fully automated calculation of size-specific dose estimates (SSDE) in thoracic and head CT examinations

    Science.gov (United States)

    Anam, C.; Haryanto, F.; Widita, R.; Arif, I.; Dougherty, G.

    2016-03-01

    The purpose of this study is to automatically calculate and then investigate the size- specific dose estimate (SSDE) in thoracic and head CT examinations undertaken using standard imaging protocols. The effective diameter (Deff ), the water equivalent diameter (Dw ), and the SSDE were calculated automatically from patient images. We investigated sixteen adult patients who underwent a CT head examination and thirty adult patients who underwent a CT thorax examination. Our results showed that the Dw value in the thoracic region was 4.5% lower than the value of Deff , while the Dw value in the head region was 8.6% higher than the value of Deff . The relationships between diameter (Deff and Dw ) and CTDIvol were distinctive. In the head region, decreasing the patient diameter resulted in a constant CTDIvol due to the tube current modulation (TCM) being off, while in the thoracic region decreasing the patient diameter resulted in a decrease in value of CTDIvol due to TCM being on. In the head region, decreasing the patient diameter resulted in an increase in the value of SSDE, while in the thoracic region decreasing the patient diameter resulted in a decrease in the value of SSDE.

  4. Computed tomography (CT) findings of the pleural metastasis effusion: the examination of 100 patients

    International Nuclear Information System (INIS)

    Arenas, J. J.; Alonso, S.; Gil, S.; Fernandez, F.; Lloret, M.

    1999-01-01

    To evaluate the computed tomography (CT) findings in a series of 100 pleural metastasis effusions. A retrospective study was carried out that consisted of assessing the CT images of 100 malignant pleural metastasis effusions, evaluating the amount of the effusion, its distribution, the presence of swelling or nodules in the different pleural surfaces, the existence and the characteristics of the extrapleural fat and the changes in other locations different to the pleural cavity, mainly the mediastinum and the pulmonary parenchyma. The effusion was located in 12 patients. The amount of the effusion was slight in 14% and massive in 10% of the sick patients. Pleural nodules were detected in 19% of the studies, in all those that affected the costal parental pleura, being less frequent in the other pleural surfaces. The costal parental pleura was swollen in 43% of the sick patients. 52 sick patients did not have any swelling nor pleural nodules, with the pleural effusion being the only sign of pleural metastasis. Changes in the rest of the thorax were frequent in relation to the malignant illness that causes the effusion and appeared in 67% of the sick patients. The patients with pleural effusions of malignant etiology showed variable CT findings, that in general were non-specific, and in almost half the cases no pleural changes can be seen apart from the effusion. (Author) 13 refs

  5. Spiral 2 Week

    International Nuclear Information System (INIS)

    2007-01-01

    The main goal of this meeting is to present and discuss the current status of the Spiral-2 project at GANIL in front of a large community of scientists and engineers. Different issues have been tackled particularly the equipment around Spiral-2 like injectors, cryo-modules or beam diagnostics, a workshop was devoted to other facilities dedicated to radioactive ion beam production. This document gathers only the slides of the presentations

  6. Spiral 2 Week

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The main goal of this meeting is to present and discuss the current status of the Spiral-2 project at GANIL in front of a large community of scientists and engineers. Different issues have been tackled particularly the equipment around Spiral-2 like injectors, cryo-modules or beam diagnostics, a workshop was devoted to other facilities dedicated to radioactive ion beam production. This document gathers only the slides of the presentations.

  7. Comparison of image quality and radiation dose between high-pitch mode and low-pitch mode spiral chest CT in small uncooperative children: The effect of respiratory rate

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Ho; Choi, Young Hun; Cho, Hyun-Hae; Lee, So Mi [Seoul National University Hospital, Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Shin, Su-Mi [SMG-SNU Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Cheon, Jung-Eun; Kim, Woo Sun; Kim, In-One [Seoul National University Hospital, Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2016-04-15

    To compare image quality and radiation dose between high-pitch mode (HPM) and low-pitch mode (LPM) CT in young children. Forty-seven children (mean age 35.6 months; range, 0-126 months) underwent 49 CT examinations in HPM or LPM and were divided into high or low respiratory rate (RR) groups. A qualitative image quality was compared between the two modes. The volume CT dose index (CTDI{sub vol}) and dose-length product (DLP) were evaluated from the dose reports, and effective doses were assessed using a paediatric phantom. Image quality was generally better for HPM than LPM (diagnostic acceptance score, 4.00 vs. 3.46, P = 0.004); the difference was more prominent in the high RR group (4.00 vs. 3.22, P = 0.001). However, there was no significant difference in the low RR group. The mean DLP value was higher in HPM than LPM (29.48 mGy . cm vs. 23.46 mGy . cm, P = 0.022), while CTDI{sub vol} was not significantly different. The total effective radiation dose was 26 % higher in HPM than LPM (1.82 mSv vs. 1.44 mSv). LPM can be considered for paediatric lung evaluation in young children with low RRs to reduce radiation dose while maintaining favourable image quality. (orig.)

  8. CT colonography for preoperative examination of the proximal colon using a transanal drainage tube for acute malignant colonic obstruction

    International Nuclear Information System (INIS)

    Sasaki, Kazuaki; Hirano, Yuji; Oono, Keisuke; Sasaki, Kazunori; Someya, Tetsufumi; Harada, Keisuke; Ezoe, Eiri; Furuhata, Tomohisa; Hirata, Koichi

    2011-01-01

    The purpose of this study was to evaluate the feasibility of CT colonography for preoperative examination of the proximal colon using a transanal drainage tube in patients with acute colon obstruction caused by colorectal cancer. Ten patients who received initial treatment for acute malignant colon obstruction at our hospital between June 2004 and December 2008 were studied. In these patients, elective surgery was possible after transanal drainage tube insertion, and the colon on the oral side from the cancer lesion was examined using a drainage tube. Air was injected through the tube into the oral side of the colon, and CT colonography was assessed for the presence or absence of lesions on the oral side. The images of the oral side of the colon were good enough to allow adequate interpretation in 9 of the 10 patients. In the first patient, the visualization of the area near the lesion was somewhat fair, although the right side colon was well visualized. There were no complications associated with this examination. The present preoperative examination using a transanal drainage tube was useful for determining the extent of intestinal resection when patients were not candidates for colonoscopy or barium enema examination. (author)

  9. Computed tomography in the detection of pulmonary metastases. Improvement by application of spiral technology

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Hansen, M.; Schweden, F.; Strunk, H.; Mildenberger, P.; Thelen, M.

    1994-01-01

    Computed tomography is the imaging modality of choice for detection or exclusion of pulmonary metastases. In most cases these are spheric, multiple, bilateral, and located in the peripheral areas of the middle and lower fields of the lungs. Differential diagnosis of solitary pulmonary nodules is difficult. Evaluating whether they are malignant or benign is insufficient despite the application of multiple CT criteria. Spiral computed tomography acquiring an imaging volume in a breathhold has led to significant improvement in the sensitivity of detecting pulmonary nodules. Imaging protocols are presented, and the influence of the different parameters is discussed. Although not all pulmonary metastases may be detected with spiral computed tomography, it is the most important examination when considering pulmonary metastasectomy. Computed tomography is the imaging modality of choice when monitoring pulmonary metastases during systemic therapeutic regimens by measuring all nodules or 'indicator lesions'. (orig.) [de

  10. Acute pulmonary embolism: prediction of cor pulmonale and short-term patient survival from assessment of cardiac dimensions in routine multidetector-row CT; Mehrschicht-Spiral-CT bei vermuteter und inzidenteller akuter Lungenembolie: prognostischer Wert morpholoqischer Herzparameter

    Energy Technology Data Exchange (ETDEWEB)

    Engeike, C. [Radiologie, Klinikum rechts der Isar der Technischen Univ. Muenchen (Germany); Rummeny, E.; Marten, K. [Inst. fuer Roentgendiagnostik, Klinikum rechts der Isar der Technischen Univ. Muenchen (Germany)

    2006-10-15

    Purpose: evaluation of the prognostic value of morphological cardiac parameters in patients with suspected and incidental acute pulmonary embolism (PE) using multidetector-row chest CT (MSCT). Materials and methods: 2335 consecutive MSCT scans were evaluated for the presence of PE. The arterial enhancement and analysability of pulmonary arteries and the heart were assessed as parameters of the scan quality. The diastolic right and left ventricular short axes (RV{sub D}, LV{sub D}) and the interventricular septal deviation (ISD) were measured in all PE-positive patients and the echocardiography reports were reviewed. The clinical data assessment included cardio-respiratory and other co-morbidities, systemic anticoagulant therapy (ACT), and the 30-day outcome. Predictors of acute cor pulmonale and the short-term outcome were calculated by univariate and multivariate logistic regressions including odds ratios (OR) and ROC analyses using positive (PPV) and negative predictive values (NPV). Results: 90 patients with acute PE were included (36 with clinically suspected PE, 54 with incidental PE). 26 patients had cardio-respiratory co-morbidities. Four patients underwent systemic thrombolysis, 43 underwent anticoagulation in therapeutic doses, 19 underwent anticoagulation in prophylactic doses, and 24 patients did not undergo ACT. 15 of 41 patients had echocardiographic evidence of acute cor pulmonale. 8 patients died within 30 days. The RV{sub D} was the best independent predictor of acute cor pulmonale (p = 0,002, OR = 9.16, PPV = 0.68, NPV=1 at 4.49 cm cut off) and short-term outcome (p= 0,0005, OR = 2.82, PPV = 0.23, NPV = 0.98 at 4.75 cm cut off). The RV{sub D}/LV{sub D} ratio had a PPV of 0.85 for cor pulmonale. (orig.)

  11. Optimized preoperative planning of calcaneal fractures using spiral computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Freund, M.; Hohendorf, B.; Heller, M. [Department of Radiology, Medical School, University of Kiel (Germany); Thomsen, M. [Department of Orthopedic Surgery, Medical School, University of Heidelberg (Germany); Zenker, W. [Department of Traumatology, Medical School, University of Kiel (Germany)

    1999-06-01

    The aim of this study was the evaluation of spiral-CT examinations in preoperative planning of calcaneal fractures supported by 3D reconstructions after electronic disarticulation. We examined 45 patients with 47 calcaneal fractures with diagnostic spiral-CT examinations in a prospective study. In addition to the conventional axial slices and sagittal reconstructions, 3D reconstructions prior to and after electronic disarticulation were performed and rated by orthopaedic surgeons and radiologists. The following diagnostic criteria were rated: involvement of articular facets, number of fragments and hindfoot deformities. Axial slices were considered to be the gold standard, because not all patients underwent surgical treatment. Axial slices showed involvement of 90 articular facets (100 %). Three-dimensional reformations after electronic disarticulation depicted 82 fractures (82 of 90, 91 %), sagittal reconstructions 63 fractures (63 of 90, 70 %). Three-dimensional reconstructions without electronic disarticulation showed five fractures (5 of 90, 5.5 %). The number of fragments was demonstrated best on sagittal reconstructions (two, three or four fragments); five fragments were diagnosed best on axial slices, and 3D reconstruction without electronic disarticulation showed only a very small number of fragments, due to overlaying bones. Hindfoot deformities (lateralisation, varus deformation, shortening) were demonstrated best on axial slices, except in terms of showing height reduction, which was demonstrated better on sagittal and 3D reconstructions. Three-dimensional reconstructions after electronic disarticulation support a clear understanding of the 3D position of the fragments and of their displacement in comparison with 3D reconstruction without electronic disarticulation, which is essential for an effective surgical reduction. Due to the potential manipulation of surface-oriented 3D reconstructions, regardless of whether electronic disarticulation is used

  12. Ovarian Cancer: Prevalence in Incidental Simple Adnexal Cysts Initially Identified in CT Examinations of the Abdomen and Pelvis.

    Science.gov (United States)

    Boos, Johannes; Brook, Olga R; Fang, Jieming; Brook, Alexander; Levine, Deborah

    2018-01-01

    Purpose To evaluate the rate of malignancy in incidentally detected simple adnexal cysts at computed tomography (CT) to determine if simple-appearing cysts require follow-up. Materials and Methods In this HIPAA-compliant, institutional review board-approved retrospective cohort study, an institutional database was searched for abdominal and pelvic CT studies performed between June 2003 and December 2010 in women reported to have adnexal cysts. Adnexal cyst characterization was determined by prospective report description as well as image review by a research fellow and by a fellowship-trained abdominal radiologist for examinations with disagreement between the original report and the research fellow's assessment. Patients with known ovarian cysts or ovarian cancer at time of the index CT examination were excluded. Clinical outcome was assessed by using follow-up imaging studies, medical records, and the state cancer registry. Benign outcome was determined by benign findings at surgery, a decrease in size or resolution of a simple-appearing cyst at follow-up imaging, or stability of the cyst for at least 1 year. Descriptive statistics and 95% confidence intervals (CIs) were calculated. Results Among 42 111 women who underwent abdominal and pelvic CT examinations in the study period, 2763 (6.6%; 95% CI: 6.3%, 6.8%) (mean age, 48.1 years ± 18.1; range, 15-102 years) had a newly detected finding of ovarian cyst described in the body or impression section of the report. Median cyst size was 3.1 cm (range, 0.8-20.0 cm). Eighteen (0.7%; 95% CI: 0.4%, 1.0%) of 2763 patients were found to have ovarian cancer after an average follow-up of 5.1 years ± 3.8 (range, 0-12.8 years). None (95% CI: 0%, 0.4%) of 1031 women with simple-appearing cysts were given a diagnosis of ovarian cancer. This included none (95% CI: 0%, 0.4%) of 904 women with simple-appearing cysts with an adequate reference standard for benign outcome. Conclusion The prevalence of previously unknown adnexal

  13. Radiation exposure of ovarian cancer patients: contribution of CT examinations performed on different MDCT (16 and 64 slices) scanners and image quality evaluation: an observational study.

    Science.gov (United States)

    Rizzo, Stefania; Origgi, Daniela; Brambilla, Sarah; De Maria, Federica; Foà, Riccardo; Raimondi, Sara; Colombo, Nicoletta; Bellomi, Massimo

    2015-05-01

    The objective of this study is to compare radiation doses given to ovarian cancer patients by different computed tomographies (CTs) and to evaluate association between doses and subjective and objective image quality.CT examinations included were performed either on a 16-slice CT, equipped with automatic z-axis tube current modulation, or on a 64-slice CT, equipped with z-axis, xy-axis modulation, and adaptive statistical iterative algorithm (ASIR). Evaluation of dose included the following dose descriptors: volumetric CT dose index (CTDIvol), dose length product (DLP), and effective dose (E). Objective image noise was evaluated in abdominal aorta and liver. Subjective image quality was evaluated by assessment of image noise, spatial resolution and diagnostic acceptability.Mean and median CTDIvol, DLP, and E; correlation between CTDIvol and DLP and patients' weight; comparison of objective noise for the 2 scanners; association between dose descriptors and subjective image quality.The 64-slice CT delivered to patients 24.5% lower dose (P CT. There was a significant correlation between all dose descriptors (CTDIvol, DLP, E) and weight (P CT scanners. There was a significant correlation between dose descriptors and image noise for the 64-slice CT, and between dose descriptors and spatial resolution for the 16-slice CT.Current dose reduction systems may reduce radiation dose without significantly affecting image quality and diagnostic acceptability of CT exams.

  14. Body Size-Specific Organ and Effective Doses of Chest CT Screening Examinations of the National Lung Screening Trial.

    Science.gov (United States)

    Lee, Choonsik; Flynn, Michael J; Judy, Phillip F; Cody, Dianna D; Bolch, Wesley E; Kruger, Randell L

    2017-05-01

    We calculated body size-specific organ and effective doses for 23,734 participants in the National Lung Screening Trial (NLST) using a CT dose calculator. We collected participant-specific technical parameters of 23,734 participants who underwent CT in the clinical trial. For each participant, we calculated two sets of organ doses using two methods. First, we computed body size-specific organ and effective doses using the National Cancer Institute CT (NCICT) dosimetry program, which is based on dose coefficients derived from a library of body size-dependent adult male and female computational phantoms. We then recalculated organ and effective doses using dose coefficients from reference size phantoms for all examinations to investigate potential errors caused by the lack of body size consideration in the dose calculations. The underweight participants (body mass index [BMI; weight in kilograms divided by the square of height in meters] dose (median, 4.93 mGy) than the obese participants (BMI > 30) (3.90 mGy). Thyroid doses were approximately 1.3- to 1.6-fold greater than the lung doses (6.3-6.5 mGy). The reference phantom-based dose calculation underestimates the body size-specific lung dose by up to 50% for the underweight participants and overestimates that value by up to 200% for the overweight participants. The median effective dose ranges from 2.01 mSv in obese participants to 2.80 mSv in underweight participants. Body size-specific organ and effective doses were computed for 23,734 NLST participants who underwent low-dose CT screening. The use of reference size phantoms can lead to significant errors in organ dose estimates when body size is not considered in the dose assessment.

  15. Evaluation of organ doses and specific k effective dose of 64-slice CT thorax examination using an adult anthropomorphic phantom

    Science.gov (United States)

    Hashim, S.; Karim, M. K. A.; Bakar, K. A.; Sabarudin, A.; Chin, A. W.; Saripan, M. I.; Bradley, D. A.

    2016-09-01

    The magnitude of radiation dose in computed tomography (CT) depends on the scan acquisition parameters, investigated herein using an anthropomorphic phantom (RANDO®) and thermoluminescence dosimeters (TLD). Specific interest was in the organ doses resulting from CT thorax examination, the specific k coefficient for effective dose estimation for particular protocols also being determined. For measurement of doses representing five main organs (thyroid, lung, liver, esophagus and skin), TLD-100 (LiF:Mg, Ti) were inserted into selected holes in a phantom slab. Five CT thorax protocols were investigated, one routine (R1) and four that were modified protocols (R2 to R5). Organ doses were ranked from greatest to least, found to lie in the order: thyroid>skin>lung>liver>breast. The greatest dose, for thyroid at 25 mGy, was that in use of R1 while the lowest, at 8.8 mGy, was in breast tissue using R3. Effective dose (E) was estimated using three standard methods: the International Commission on Radiological Protection (ICRP)-103 recommendation (E103), the computational phantom CT-EXPO (E(CTEXPO)) method, and the dose-length product (DLP) based approach. E103 k factors were constant for all protocols, 8% less than that of the universal k factor. Due to inconsistency in tube potential and pitch factor the k factors from CTEXPO were found to vary between 0.015 and 0.010 for protocols R3 and R5. With considerable variation between scan acquisition parameters and organ doses, optimization of practice is necessary in order to reduce patient organ dose.

  16. Plasma Generator Using Spiral Conductors

    Science.gov (United States)

    Szatkowski, George N. (Inventor); Dudley, Kenneth L. (Inventor); Ticatch, Larry A. (Inventor); Smith, Laura J. (Inventor); Koppen, Sandra V. (Inventor); Nguyen, Truong X. (Inventor); Ely, Jay J. (Inventor)

    2016-01-01

    A plasma generator includes a pair of identical spiraled electrical conductors separated by dielectric material. Both spiraled conductors have inductance and capacitance wherein, in the presence of a time-varying electromagnetic field, the spiraled conductors resonate to generate a harmonic electromagnetic field response. The spiraled conductors lie in parallel planes and partially overlap one another in a direction perpendicular to the parallel planes. The geometric centers of the spiraled conductors define endpoints of a line that is non-perpendicular with respect to the parallel planes. A voltage source coupled across the spiraled conductors applies a voltage sufficient to generate a plasma in at least a portion of the dielectric material.

  17. Evaluation of organ doses and specific k effective dose of 64-slice CT thorax examination using an adult anthropomorphic phantom

    International Nuclear Information System (INIS)

    Hashim, S.; Karim, M.K.A.; Bakar, K.A.; Sabarudin, A.; Chin, A.W; Saripan, M.I.; Bradley, D.A.

    2016-01-01

    The magnitude of radiation dose in computed tomography (CT) depends on the scan acquisition parameters, investigated herein using an anthropomorphic phantom (RANDO®) and thermoluminescence dosimeters (TLD). Specific interest was in the organ doses resulting from CT thorax examination, the specific k coefficient for effective dose estimation for particular protocols also being determined. For measurement of doses representing five main organs (thyroid, lung, liver, esophagus and skin), TLD-100 (LiF:Mg, Ti) were inserted into selected holes in a phantom slab. Five CT thorax protocols were investigated, one routine (R1) and four that were modified protocols (R2 to R5). Organ doses were ranked from greatest to least, found to lie in the order: thyroid>skin>lung>liver>breast. The greatest dose, for thyroid at 25 mGy, was that in use of R1 while the lowest, at 8.8 mGy, was in breast tissue using R3. Effective dose (E) was estimated using three standard methods: the International Commission on Radiological Protection (ICRP)-103 recommendation (E103), the computational phantom CT-EXPO (E(CTEXPO)) method, and the dose-length product (DLP) based approach. E103 k factors were constant for all protocols, ~8% less than that of the universal k factor. Due to inconsistency in tube potential and pitch factor the k factors from CTEXPO were found to vary between 0.015 and 0.010 for protocols R3 and R5. With considerable variation between scan acquisition parameters and organ doses, optimization of practice is necessary in order to reduce patient organ dose. - Highlights: • Using TLD-100 dosimeters and a RANDO phantom 5 CT thorax protocol organ doses were assessed. • The specific k coefficient for effective dose estimation of protocols differed with approach. • Organ dose was observed to decrease in the order: thyroid>skin>lung>liver>breast. • E103 k factors were constant for all protocols, lower by ~8% compared to the universal k factor.

  18. The spinning ball spiral

    Science.gov (United States)

    Dupeux, Guillaume; Le Goff, Anne; Quéré, David; Clanet, Christophe

    2010-09-01

    We discuss the trajectory of a fast revolving solid ball moving in a fluid of comparable density. As the ball slows down owing to drag, its trajectory follows an exponential spiral as long as the rotation speed remains constant: at the characteristic distance L where the ball speed is significantly affected by the drag, the bending of the trajectory increases, surprisingly. Later, the rotation speed decreases, which makes the ball follow a second kind of spiral, also described in the paper. Finally, the use of these highly curved trajectories is shown to be relevant to sports.

  19. Quarkyonic Chiral Spirals

    International Nuclear Information System (INIS)

    Toru, Kojo; Hidaka, Y.; Pisarski, R.; McLerran, L.

    2010-01-01

    We argue the properties of confining dense quark matter, 'quarkyonic' matter, from the viewpoint of both bulk properties and excitation modes. After a brief review of confining aspects, the chiral breaking/restoration will be discussed. We argue that the strong infrared correlations induce the chiral spiral, i.e., the spatial modulation of the chiral condensate which breaks the chiral symmetry locally but restore it globally. The effective dimensional reduction takes place, allowing us to analyzing the system as 2D model in which several exact results can be explicitly derived. We also discuss the excitation spectra, both mesonic and baryonic ones, on the chiral spiral. (author)

  20. Cochlea and other spiral forms in nature and art.

    Science.gov (United States)

    Marinković, Slobodan; Stanković, Predrag; Štrbac, Mile; Tomić, Irina; Ćetković, Mila

    2012-01-01

    The original appearance of the cochlea and the specific shape of a spiral are interesting for both the scientists and artists. Yet, a correlation between the cochlea and the spiral forms in nature and art has been very rarely mentioned. The aim of this study was to investigate the possible correlation between the cochlea and the other spiral objects in nature, as well as the artistic presentation of the spiral forms. We explored data related to many natural objects and examined 13,625 artworks created by 2049 artists. We also dissected 2 human cochleas and prepared histologic slices of a rat cochlea. The cochlea is a spiral, cone-shaped osseous structure that resembles certain other spiral forms in nature. It was noticed that parts of some plants are arranged in a spiral manner, often according to Fibonacci numbers. Certain animals, their parts, or their products also represent various types of spirals. Many of them, including the cochlea, belong to the logarithmic type. Nature created spiral forms in the living world to pack a larger number of structures in a limited space and also to improve their function. Because the cochlea and other spiral forms have a certain aesthetic value, many artists presented them in their works of art. There is a mathematical and geometric correlation between the cochlea and natural spiral objects, and the same functional reason for their formation. The artists' imagery added a new aspect to those domains. Obviously, the creativity of nature and Homo sapiens has no limits--like the infinite distal part of the spiral. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Possibilities for exposure reduction in computed tomography examination of acute chest pain; Moeglichkeiten der Dosisreduktion bei CT-Untersuchungen des akuten Thoraxschmerzes

    Energy Technology Data Exchange (ETDEWEB)

    Becker, H.C. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2012-10-15

    Electrocardiogram-gated (ECG) computed tomography (CT) investigations can be accompanied by high amounts of radiation exposure. This is particularly true for the investigation of patients with unclear and acute chest pain. The common approach in patients with acute chest pain is standard spiral CT of the chest. The chest pain or triple-rule-out CT protocol is a relatively new ECG-gated protocol of the entire chest. This article reviews and discusses different techniques for the CT investigation of patients with acute chest pain. By applying the appropriate scan technique, the radiation exposure for an ECG-gated protocol must not necessarily be higher than a standard chest CT scan Aortic pathologies are far better depicted by ECG-gated scan protocols and depending on the heart rate coronary artery disease can also be detected at the same time. The use of ECG-triggered scans will not support the diagnostics of the pulmonary arteries. However, in unspecific chest pain an ECG-triggered scan protocol can provide information on the differential diagnosis. (orig.) [German] EKG-getriggerte CT-Untersuchungen koennen mit einer relativ hohen Strahlenexposition einhergehen. Dies gilt im besonderen Masse fuer die Untersuchung des gesamten Thorax bei Patienten mit unklarem akutem Thoraxschmerz. Bisher wurden Untersuchungen bei Patienten mit akutem Thoraxschmerz in Spiraltechnik ohne EKG-Triggerung durchgefuehrt. Das ''Chest-pain-'' oder ''Triple-rule-out''-Protokoll ist ein neues EKG-getriggertes Untersuchungsprotokoll des gesamten Thorax. Im vorliegenden Artikel werden verschiedene Techniken zur CT-Untersuchung von Patienten mit akutem Thoraxschmerz vorgestellt und besprochen. Mit der richtigen Untersuchungstechnik muss die Strahlenexposition fuer ein EKG-getriggertes Untersuchungsprotokoll nicht hoeher sein als eine Standarduntersuchung ohne EKG. Mit einem EKG-getriggerten Untersuchungsprotokoll laesst sich die Aorta in Hinblick auf

  2. Tracking Target and Spiral Waves

    DEFF Research Database (Denmark)

    Jensen, Flemming G.; Sporring, Jon; Nielsen, Mads

    2002-01-01

    A new algorithm for analyzing the evolution of patterns of spiral and target waves in large aspect ratio chemical systems is introduced. The algorithm does not depend on finding the spiral tip but locates the center of the pattern by a new concept, called the spiral focus, which is defined by the...

  3. Are spiral galaxies heavy smokers?

    International Nuclear Information System (INIS)

    Davies, J.; Disney, M.; Phillipps, S

    1990-01-01

    The dustiness of spiral galaxies is discussed. Starburst galaxies and the shortage of truly bright spiral galaxies is cited as evidence that spiral galaxies are far dustier than has been thought. The possibility is considered that the dust may be hiding missing mass

  4. Radiation dose evaluation in tomosynthesis and C-arm cone-beam CT examinations with an anthropomorphic phantom.

    Science.gov (United States)

    Koyama, Shuji; Aoyama, Takahiko; Oda, Nobuhiro; Yamauchi-Kawaura, Chiyo

    2010-08-01

    The objective of this study was to evaluate organ dose and the effective dose to patients undergoing tomosynthesis (TS) and C-arm cone-beam computed tomography (CBCT) examinations and to compare the doses to those in multidetector CT (MDCT) scans. Patient doses were measured with small sized silicon-photodiode dosimeters, 48 in number, which were implanted at various tissue and organ positions within an anthropomorphic phantom. Output signals from photodiode dosimeters were read out on a personal computer, from which organ and effective doses were computed. The doses in head, chest, abdomen, and hip-joint TS, and in head and abdomen C-arm CBCT were evaluated for routine protocols on Shimadzu TS and C-arm CBCT systems, and the doses in MDCT with the same scan regions as in TS and CBCT were on Toshiba 64-detector-row CT scanners. In TS examination of the head, chest, abdomen, and hip-joint, organ doses for organs within scan ranges were 1-4 mGy, and effective doses were 0.07 mSv for the head scan and around 1 mSv for other scans. In C-arm CBCT examinations of the head and abdomen, organ doses within scan range were 2-37 mGy, and effective doses were 1.2 mSv for the head scan and 4-5 mSv for abdominal scans. Effective doses in TS examinations were approximately a factor of 10 lower, while the doses in CBCT examinations were nearly the same level, compared to the doses in the corresponding MDCT examinations. TS examinations with low doses and excellent resolutions in coronal images compared to recent MDCT would widely be used in tomographic examinations of the chest, abdomen, pelvis, skeletal-joints, and knee instead of MDCT examinations with significantly high doses. Since patient dose in C-arm CBCT was nearly the same level as that in recent MDCT, the same consideration for high radiation dose would be required for the use of CBCT.

  5. Spiraling into Transformative Learning

    Science.gov (United States)

    Cranton, Patricia

    2010-01-01

    This article explores how technical and vocational learning may spiral into transformative learning. Transformative learning theory is reviewed and the learning tasks of critical theory are used to integrate various approaches to transformative learning. With this as a foundation, the article explores how transformative learning can be fostered in…

  6. Archimedean Voronoi spiral tilings

    Science.gov (United States)

    Yamagishi, Yoshikazu; Sushida, Takamichi

    2018-01-01

    We study the transition of the number of spirals (called parastichy in the theory of phyllotaxis) within a Voronoi tiling for Archimedean spiral lattices. The transition of local parastichy numbers within a tiling is regarded as a transition at the base site point in a continuous family of tilings. This gives a natural description of the quasiperiodic structure of the grain boundaries. It is proved that the number of tiles in the grain boundaries are denominators of rational approximations of the argument (called the divergence angle) of the generator. The local parastichy numbers are non-decreasing functions of the plastochron parameter. The bifurcation diagram of local parastichy numbers has a Farey tree structure. We also prove Richards’ formula of spiral phyllotaxis in the case of Archimedean Voronoi spiral tilings, and show that, if the divergence angle is a quadratic irrational number, then the shapes of tiles in the grain boundaries are close to rectangles. If the divergence angle is linearly equivalent to the golden section, then the shape of tiles in the grain boundaries is close to square.

  7. Properties of spiral resonators

    International Nuclear Information System (INIS)

    Haeuser, J.

    1989-10-01

    The present thesis deals with the calculation and the study of the application possibilities of single and double spiral resonators. The main aim was the development and the construction of reliable and effective high-power spiral resonators for the UNILAC of the GSI in Darmstadt and the H - -injector for the storage ring HERA of DESY in Hamburg. After the presentation of the construction and the properties of spiral resonators and their description by oscillating-circuit models the theoretical foundations of the bunching are presented and some examples of a rebuncher and debuncher and their influence on the longitudinal particle dynamics are shown. After the description of the characteristic accelerator quantities by means of an oscillating-circuit model and the theory of an inhomogeneous λ/4 line it is shown, how the resonance frequency and the efficiency of single and double spiral resonators can be calculated from the geometrical quantities of the structure. In the following the dependence of the maximal reachable resonator voltage in dependence on the gap width and the surface of the drift tubes is studied. Furthermore the high-power resonators are presented, which were built for the different applications for the GSI in Darmstadt, DESY in Hamburg, and for the FOM Institute in Amsterdam. (orig./HSI) [de

  8. Safety and patient comfort with iodixanol: a postmarketing surveillance study in 9515 patients undergoing diagnostic CT examinations

    International Nuclear Information System (INIS)

    Haeussler, Marc D.

    2010-01-01

    Background: Iodinated radiographic contrast media are considered safe diagnostic drugs with a low incidence of adverse drug reactions. Purpose: To determine prospectively the incidence and nature of immediate and delayed adverse drug reactions occurring after administration of iodixanol for contrast-enhanced computed tomography (CT) in routine practice in nonselected patients, and to assess patient comfort (pain and sensations of heat or coldness). Material and Methods: Patient characteristics (including demographics, risk factors, indication for CT, and status of the vein used to administer iodixanol) and aspects of iodixanol administration (including dose and volume) were documented on a standardized case report form. Patients were asked to report immediate (during the visit) or delayed (occurring up to 7 days after administration of iodixanol) adverse reactions; those deemed related or possibly related to iodixanol were documented on a standardized adverse drug reaction form. Discomfort was rated by patients on a scale of 0-10 for pain, heat, and coldness; individual scores were combined into a composite score (0-30). Results: Evaluable documentation was provided for 9515 patients in 77 centers across Germany. Adverse drug reactions were reported in 70 patients (0.74%), including hypersensitivity reactions in 55 patients. Thirty patients experienced immediate reactions and 40 experienced delayed reactions. Serious adverse drug reactions were evident in five patients (0.05%). Patients with allergic diathesis appeared to be at increased risk of immediate and delayed adverse drug reactions. Discomfort was generally mild, with 72% of patients reporting a composite score of 0-3. Conclusion: In the outpatient setting, where it is often difficult to properly assess patients for specific risk factors, it was reassuring that iodixanol demonstrated an excellent safety profile in over 9500 patients undergoing diagnostic CT examinations. There were no unexpected serious

  9. Automated temporal tracking and segmentation of lymphoma on serial CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Xu Jiajing; Greenspan, Hayit; Napel, Sandy; Rubin, Daniel L. [Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States); Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, 69978 (Israel); Department of Electrical Engineering, Stanford University, Stanford, California 94305 and Department of Radiology, Stanford University, Stanford, California 94305 (United States); Department of Radiology, Stanford University, Stanford, California 94305 (United States)

    2011-11-15

    Purpose: It is challenging to reproducibly measure and compare cancer lesions on numerous follow-up studies; the process is time-consuming and error-prone. In this paper, we show a method to automatically and reproducibly identify and segment abnormal lymph nodes in serial computed tomography (CT) exams. Methods: Our method leverages initial identification of enlarged (abnormal) lymph nodes in the baseline scan. We then identify an approximate region for the node in the follow-up scans using nonrigid image registration. The baseline scan is also used to locate regions of normal, non-nodal tissue surrounding the lymph node and to map them onto the follow-up scans, in order to reduce the search space to locate the lymph node on the follow-up scans. Adaptive region-growing and clustering algorithms are then used to obtain the final contours for segmentation. We applied our method to 24 distinct enlarged lymph nodes at multiple time points from 14 patients. The scan at the earlier time point was used as the baseline scan to be used in evaluating the follow-up scan, resulting in 70 total test cases (e.g., a series of scans obtained at 4 time points results in 3 test cases). For each of the 70 cases, a ''reference standard'' was obtained by manual segmentation by a radiologist. Assessment according to response evaluation criteria in solid tumors (RECIST) using our method agreed with RECIST assessments made using the reference standard segmentations in all test cases, and by calculating node overlap ratio and Hausdorff distance between the computer and radiologist-generated contours. Results: Compared to the reference standard, our method made the correct RECIST assessment for all 70 cases. The average overlap ratio was 80.7 {+-} 9.7% s.d., and the average Hausdorff distance was 3.2 {+-} 1.8 mm s.d. The concordance correlation between automated and manual segmentations was 0.978 (95% confidence interval 0.962, 0.984). The 100% agreement in our sample

  10. Examining the subcortical infarcts in the era of acute multimodality CT imaging

    Directory of Open Access Journals (Sweden)

    Mindy Tan

    2016-12-01

    Full Text Available Background: Lacunar infarcts have been characterized as small subcortical infarcts, resulting from in situ microatheroma or lipohyalinosis in small vessels. Based on this hypothesis, such infarcts should not be associated with large areas of perfusion deficits extending beyond subcortical regions to involve cortical regions. By contrast, selected small subcortical infarcts, as defined by MR imaging in the subacute or chronic stage, may initially have large perfusion deficits or related large vessel occlusions. These infarcts with ‘lacunar’ phenotype may also be caused by disease in the parent vessel and may have very different stroke mechanisms from small vessel disease. Our aim was to describe differences in imaging characteristics between patients with small subcortical infarction with ‘lacunar phenotype’ from those with lacunar mechanism. Methods: Patients undergoing acute CT Perfusion/angiography (CTP/CTA within 6 hours of symptom onset and follow-up magnetic resonance imaging (MRI for ischaemic stroke were included (2009-2013. A lacunar infarct was defined as a single subcortical infarct (SSI ≤20 mm on follow-up MRI. Presence of perfusion deficits, vessel occlusion and infarct dimensions were compared between lacunar infarcts and other topographical infarct types. Results: Overall, 182 patients (mean age 66.4±15.3 years, 66% male were included. SSI occurred in 31 (17% patients. Of these, 12 (39% patients had a perfusion deficit compared with those with any cortical infarction (120/142, 67%, and the smallest SSI with a perfusion deficit had a diameter of <5mm. The majority of patients with SSI (8/12, 66.7% had a relevant vessel occlusion. A quarter of SSIs had a large-artery stroke mechanism evident on acute CTP/CTA. Lacunar mechanism was present in 3/8 patients with corona radiata, 5/10 lentiform nucleus, 5/6 posterior limb of internal capsule PLIC, 3/5 thalamic infarcts and 1/2 miscellaneous locations. There was a trend toward

  11. Body packers on your examination table: How helpful are plain x-ray images? A definitive low-dose CT protocol as a diagnosis tool for body packers.

    Science.gov (United States)

    Schulz, B; Grossbach, A; Gruber-Rouh, T; Zangos, S; Vogl, Th J; Eichler, K

    2014-12-01

    To analyze the clinical value and radiation dose of plain x-rays and CT in examining patients suspected of ingesting drug-filled packets. Thirty-eight patients with suspected internal concealment of drug-filled packets who were examined with plain x-rays or CT or both were included in the study. CT studies were performed using low-dose and standard-dose techniques. All radiographic images were analysed by two radiologists regarding identification of the packets and estimating the effective radiation dose from standard- and low-dose CT versus conventional x-ray examinations. Descriptive calculations were made regarding the number and density of packs and radiation dosage. The diagnostic performance of both radiologists with standard- and low-dose CT was calculated by analysing differences in the mean number of packs found. Thirty-one patients were positively identified as body packers with an average of 13 packs (min: n = 1, max: n = 58, total: n = 390); seven patients were not concealing drug packets. X-ray images were taken of 24 patients prior to CT, thus allowing a direct comparison between the two methods. The correct diagnosis was made in 42%, in 33% the radiologists were uncertain, and in 25% of drug packets were either not or wrongly identified. X-ray imaging had a positive predictive value of 20% with a negative predictive value of 81%. A total of 55 CT examinations were performed on all patients with a mean effective dose of 2 mSv (low dose) versus 9.3 mSv (standard dose). The visibility of packets on low-dose CT images compared to high-dose CT was not reduced: the radiologists identified 385 and 381 of the packets, respectively, with no difference regarding the examination technique (p = 0.24 and p = 0.253, respectively). The radiodensity of all drug-filled packets at CT ranged from 26-292 HU (mean 181.2 HU). X-ray imaging of supposed body packers leads to a significant risk of diagnostic errors and additional need for CT. Instead, a single abdominal low

  12. Image quality and age-specific dose estimation in head and chest CT examinations with organ-based tube-current modulation.

    Science.gov (United States)

    Yamauchi-Kawaura, C; Yamauchi, M; Imai, K; Ikeda, M; Aoyama, T

    2013-12-01

    The purpose of this study was to investigate the effects of an organ-based tube-current modulation (OBTCM) system on image quality and age-specific dose in head and chest CT examinations. Image noise, contrast-to-noise ratio (CNR) and image entropy were assessed using statistical and entropy analyses. Radiation doses for newborn, 6-y-old child and adult phantoms were measured with in-phantom dosimetry systems. The quality of CT images obtained with OBTCM was not different from that obtained without OBTCM. In head CT scans, the eye lens dose decreased by 20-33 % using OBTCM. In chest CT scans, breast dose decreased by 5-32 % using OBTCM. Posterior skin dose, however, increased by 11-20 % using OBTCM in head and chest CT scans. The reduction of effective dose using OBTCM was negligibly small. Detailed image quality and dose information provided in this study can be effectively used for OBTCM application.

  13. Photometry and mass modeling of spiral galaxies

    International Nuclear Information System (INIS)

    Kent, S.

    1987-01-01

    Recent estimates of the relative contributions of dark and luminous matter to the mass of spiral galaxies are reviewed. In these studies, the galactic mass distribution is modeled on the basis of photometric and kinematic observational data. The accuracy of current photometry is discussed; the three-dimensional structure of spiral galaxies and the techniques used in bulge-disk decomposition are examined; and mass models incorporating rotation curves are presented. The disk mass/luminosity ratios in the red band (corrected for internal extinction) are found to range from 1.6 to 3.2, with no particular radius at which dark matter dominates. 20 references

  14. Radiation dose from X-ray examinations of impacted canines: cone beam CT vs two-dimensional imaging.

    Science.gov (United States)

    Kadesjö, Nils; Lynds, Randi; Nilsson, Mats; Shi, Xie-Qi

    2018-02-01

    To compare the radiation dose to children examined for impacted canines, using two-dimensional (2D) examinations (panoramic and periapical radiographs) and cone beam CT (CBCT). Organ doses were determined using an anthropomorphic 10-year-old child phantom. Two CBCT devices, a ProMax3D and a NewTom5G, were examined using thermoluminescent dosimeters. For the panoramic radiograph, a Promax device was used and for periapical radiographs, a Prostyle device with a ProSensor digital sensor was used. Both the panoramic and the intraoral devices were examined using Gafchromic-QR2 dosimetric film placed between the phantom slices. ProMax3D and NewTom5G resulted in an effective dose of 88 µSv and 170 µSv respectively. A panoramic radiograph resulted in an effective dose of 4.1 µSv, while a periapical radiograph resulted in an effective dose of 0.6 µSv and 0.7 µSv using a maxillary lateral projection and central maxillary incisor projection respectively. The effective dose from CBCT ranged from 140 times higher dose (NewTom5G compared to two periapical radiographs) to 15 times higher dose (ProMax3D compared to three periapical and one panoramic radiograph) than a 2D examination.

  15. SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Weir, V [Baylor Scott and White Healthcare System, Dallas, TX (United States); Zhang, J [University of Kentucky, Lexington, KY (United States)

    2016-06-15

    Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash in one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.

  16. Research and development of the system for group examination of lung cancer by helical CT

    International Nuclear Information System (INIS)

    2003-03-01

    For the ultimate purpose of heavy particle therapy of lung cancer at an early stage, the system in the title with low dose radiation has been investigated by cooperation of NIRS (as a leading part) and medical/industrial facilities all over the country. The project started essentially in 1984 and has been continuing at 2003. This book described Results hitherto and Materials for application to medical care at disaster (Hanshin-Awaji Earthquake Disaster in 1995) together with reference materials. Results contain all fields of nuclear medicine and of imaging involved in examination/diagnosis of lung cancer, achieved by NIRS, by Health management center and Faculty of Medicine, Chiba University and Japan Anti-Tuberculosis Association in Chiba, by the 3rd Department of Internal Medicine, Fac. Med., Chiba Univ., by Osaka Medical Center for Cancer and Cardiovascular Diseases, by Nippon Med. School, Arakawa-ku cancer protection center and Tokyo Metropolitan Univ. of Health Sciences, by Hitachi health management center, by Fukui Med. College, by Hitachi Medical Corp., by NTT research laboratories, and by Toyohashi Univ. of Technology. The Materials involve Process and summary of conducting the medical care activities, Improvement of the examination automobile, Supplementary equipments and measures for legal problems, System for the medical care activities, Record of the examination automobile activities, Problems in future, and Completion of the medical activities. Reference materials are related with the Materials above. (N.I.)

  17. Are CT Scans a Satisfactory Substitute for the Follow-Up of RSA Migration Studies of Uncemented Cups? A Comparison of RSA Double Examinations and CT Datasets of 46 Total Hip Arthroplasties

    Directory of Open Access Journals (Sweden)

    Volker Otten

    2017-01-01

    Full Text Available As part of the 14-year follow-up of a prospectively randomized radiostereometry (RSA study on uncemented cup fixation, two pairs of stereo radiographs and a CT scan of 46 hips were compared. Tantalum beads, inserted during the primary operation, were detected in the CT volume and the stereo radiographs and used to produce datasets of 3D coordinates. The limit of agreement between the combined CT and RSA datasets was calculated in the same way as the precision of the double RSA examination. The precision of RSA corresponding to the 99% confidence interval was 1.36°, 1.36°, and 0.60° for X-, Y-, and Z-rotation and 0.40, 0.17, and 0.37 mm for X-, Y-, and Z-translation. The limit of agreement between CT and RSA was 1.51°, 2.17°, and 1.05° for rotation and 0.59, 0.56, and 0.74 mm for translation. The differences between CT and RSA are close to the described normal 99% confidence interval for precision in RSA: 0.3° to 2° for rotation and 0.15 to 0.6 mm for translation. We conclude that measurements using CT and RSA are comparable and that CT can be used for migration studies for longitudinal evaluations of patients with RSA markers.

  18. Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

    Science.gov (United States)

    Zeigler, Ryan A.

    2014-01-01

    An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

  19. Theory of spiral structure

    International Nuclear Information System (INIS)

    Lin, C.C.

    1977-01-01

    The density wave theory of galactic spirals has now developed into a form suitable for consideration by experts in Applied Mechanics. On the one hand, comparison of theoretical deductions with observational data has convinced astrophysicists of the validity of the basic physical picture and the calculated results. On the other hand, the dynamical problems of a stellar system, such as those concerning the origin of spiral structure in galaxies, have not been completely solved. This paper reviews the current status of such developments, including a brief summary of comparison with observations. A particularly important mechanism, currently called the mechanism of energy exchange, is described in some detail. The mathematical problems and the physical processes involved are similar to those occurring in certain instability mechanisms in the 'magnetic bottle' designed for plasma containment. Speculations are given on the future developments of the theory and on observational programs. (Auth.)

  20. Spiral 2 workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    The accelerator and experimental facilities at GANIL will be transformed over the next 5-10 years. The centerpiece of the additions to the accelerator complex will be Spiral-2. This is the first phase of a new radioactive beam facility based on the ISOL principle. The main aim of Spiral-2 will be to produce intense, high quality beams of neutron-rich nuclei created in neutron-induced fission of heavy elements and accelerated by the existing CIME cyclotron. The principal aims of this workshop will be a) to publicize the new facilities, b) to discuss and define the science which might be carried out with them, c) to discuss the instrumentation and infrastructure required to exploit the new facilities and d) to help form collaborations of scientists wishing to design and construct the equipment needed to undertake the science programme. This document gathers most of the slides presented in the workshop.

  1. Origin choice and petal loss in the flower garden of spiral wave tip trajectories.

    Science.gov (United States)

    Gray, Richard A; Wikswo, John P; Otani, Niels F

    2009-09-01

    Rotating spiral waves have been observed in numerous biological and physical systems. These spiral waves can be stationary, meander, or even degenerate into multiple unstable rotating waves. The spatiotemporal behavior of spiral waves has been extensively quantified by tracking spiral wave tip trajectories. However, the precise methodology of identifying the spiral wave tip and its influence on the specific patterns of behavior remains a largely unexplored topic of research. Here we use a two-state variable FitzHugh-Nagumo model to simulate stationary and meandering spiral waves and examine the spatiotemporal representation of the system's state variables in both the real (i.e., physical) and state spaces. We show that mapping between these two spaces provides a method to demarcate the spiral wave tip as the center of rotation of the solution to the underlying nonlinear partial differential equations. This approach leads to the simplest tip trajectories by eliminating portions resulting from the rotational component of the spiral wave.

  2. Size-specific, scanner-independent organ dose estimates in contiguous axial and helical head CT examinations.

    Science.gov (United States)

    McMillan, Kyle; Bostani, Maryam; Cagnon, Chris; Zankl, Maria; Sepahdari, Ali R; McNitt-Gray, Michael

    2014-12-01

    AAPM Task Group 204 introduced size-specific dose estimates for pediatric and adult patients undergoing body CT examinations. This investigation extends that work to head CT exams by using Monte Carlo simulations to develop size-specific, scanner-independent CTDIvol-to-organ-dose conversion coefficients. Using eight patient models from the GSF family of voxelized phantoms, dose to the brain and lens of the eye was estimated using Monte Carlo simulations of contiguous axial and helical scans for 64-slice multidetector CT scanners from four major manufacturers. For each patient model and scan mode, scanner-independent CTDIvol-to-organ-dose conversion coefficients were calculated by normalizing organ dose by scanner-specific 16 cm CTDIvol values and averaging across all scanners. Head size was measured using both geometric and attenuation-based size metrics. Head perimeter and effective diameter (ED), both geometric size metrics, were measured directly from the GSF data at the first slice superior to the eyes. Because the GSF models' pixel data are provided in terms of organ identification numbers instead of CT numbers, an indirect estimate of water equivalent diameter (WED), an attenuation-based size metric, was determined based on the relationships between WED and both ED and perimeter for a sample of patient data. Correlations between CTDIvol-to-organ-dose conversion coefficients and the various patient size metrics were then explored. The analysis of the patient data revealed a best-fit linear relationship (R(2) of 0.87) between ED and WED across a wide variety of patient sizes. Using this relationship along with ED determined from the GSF data, WED was estimated for each GSF model. An exponential relationship between CTDIvol normalized organ dose and WED was observed for both contiguous axial and helical scanning. For head perimeter and ED measured directly from the GSF data, an exponential relationship between CTDIvol normalized organ dose and patient size was

  3. CT slice proximity rotary table and elevator for examining large objects

    International Nuclear Information System (INIS)

    Mastronardi, R.; DeCew, A.; McMahon, D.

    1984-01-01

    In a Computerized Tomography system for examining large objects, e.g. rocket motors, the problem of avoiding errors due to the heavy load is met by a support structure comprising a large bearing and an elongated cup-like support attached to the inner race of the bearing and extending coaxially away from the bearing for supporting the object and for rotating that object about the axis of the bearing. Spacers or an elevator are provided adjacent the bottom of the support for selectively translating the object along said axis. An X-ray source is positioned to beam X-rays through the object at a diametral plane closely adjacent to one face of the bearing, and a detector is provided to determine the X-ray opacity of a slice of said object closely adjacent to the bearing. The source and detector, or alternatively the bearing and cup-like support, are mounted for translation in a direction transverse to the beam direction. The support structure may be oriented vertically within a pit located below the floor of a building structure, with the bearing, source and detector being located above the floor. (author)

  4. The Effects of Spiral Taping Treatment on Low Back Pain

    Directory of Open Access Journals (Sweden)

    Hwang Jae-Ok

    2006-02-01

    Full Text Available Objective : The purpose of this study is to estimate the effects of spiral taping treatment on low back pain. Methods : 420 low back pain patients were treated with spiral taping or spiral taping plus herbal medicine, and no other treatments such as acupuncture, herbal acupuncture, and chiropractic therapy were added. We evaluated the improvement by physical examination and pain. Results : 364 patients felt no pain or inconvenience of daily life and 43 patients showed improvement of pain or symptom after 1 month of treatment. 13 patients showed same pain with before treatment. Conclusions : These results suggest spiral taping treatments contribute to the improvement of low back pain. Further study is needed for the confirmation of this effect of spiral taping treatments on low back pain.

  5. Discrepancy in reporting among specialist registrars and the role of a paediatric neuroradiologist in reporting paediatric CT head examinations

    International Nuclear Information System (INIS)

    Nagaraja, S.; Ullah, Q.; Lee, K.J.; Bickle, I.; Hon, L.Q.; Griffiths, P.D.; Raghavan, A.; Flynn, P.; Connolly, D.J.A.

    2009-01-01

    Aim: To evaluate the discrepancy rate among specialist registrars (SPR) to assess whether seniority had a bearing on the discrepancy rate. To investigate which were the commonly missed abnormalities and the consequences for teaching purposes. To investigate the role of a specialist consultant neuroradiologist in reporting paediatric head computed tomography examinations. Materials and methods: The study was carried out over a 9-month period at the regional paediatric hospital during which time 270 CT head examinations were reported. Reporting in the department is carried out by one of the five general paediatric radiologists (GR) and also a specialist paediatric neuroradiologist (NR). The NR was considered the reference standard, who corroborated in areas of discrepancy with a second senior NR for this study. Of the 270 examinations, 260 were reported by the paediatric NR, 160 were reported by the SPR, GR, and NR, and 51 were reported by an SPR and the NR. In addition, four were reported by the GR and the NR, 45 by the NR only, seven by the GR only, and three cases were reported by the GR and an SPR. The discrepancy rates were calculated for GR versus NR, and SPR versus NR. All the discrepancies were re-evaluated by a second senior NR and confirmed in all cases. The reports of the SPR were further scrutinized. The trainees of training years 1-3 were considered junior and 4-5 were considered senior. Results: There was a discrepancy in 26/164 cases (15.9%) reported by the GR and NR. There was a discrepancy in 59/211 cases (28%) reported by an SPR and NR. The chi-squared test (two-sided) showed a significant difference (p = 0.005) between the two groups. There was a discrepancy in 36/118 cases (30.5%) reported by the junior SPR and NR. There was a discrepancy in 23/93 cases (24.7%) reported by a senior SPR and NR. The chi-squared test (two-sided) showed a non-significant difference (p = 0.353) between the two groups. Conclusion: The performance of the SPR was

  6. Thin-section CT in the examination of cervical disc herniation. A prospective study with 1-mm axial and helical images

    Energy Technology Data Exchange (ETDEWEB)

    Ilkko, E. [Dept. of Diagnostic Radiology, Oulu Univ. Central Hospital (Finland); Laehde, S. [Dept. of Diagnostic Radiology, Oulu Univ. Central Hospital (Finland); Heiskari, M. [Dept. of Neurosurgery, Oulu Univ. Central Hospital (Finland)

    1996-03-01

    The aim of the investigation was to determine whether thin-section high-resolution CT imaging could replace MR imaging and/or myelography in preoperative evaluation of radiculopathy and/or myelopathy. A total of 120 patients, referred for cervical myelography (n=107) or MR imaging (n=13), were further examined with 1-mm non-contrast CT of the suspected disc space, including at least the next cephalic and caudal interspaces. Thirty-seven patients underwent Cloward`s operation, at which 32 were found to have disc herniation. The sensitivities of CT (n=37), myelography (n=29), and MR imaging (n=8) were 66%, 84%, and 86%, respectively. The corresponding figures for false-positives were 8%, 10%, and 13%. Artefacts caused by wide shoulders in the 1-mm CT images were estimated to have contributed to a false-negative finding in 8 cases. The remaining 3 false-negatives were retrospectively considered evaluation errors. The true-positive CT findings usually presented with a local disc bulge measuring over 80 HU in density. Local ligamentous hypertropy presented an indistinguishable finding in 3 cases, yielding false-positive CT findings. Conventional thin-section CT is considered a usable alternative for the evaluation of suspected cervical disc herniations in selected patients. Stocky patients with wide shoulders and a short neck are not suitable candidates, even when new generation equipment is available. (orig.).