WorldWideScience

Sample records for spinal wide-dynamic range

  1. Wide dynamic range beam profile monitor

    International Nuclear Information System (INIS)

    Lee, D.M.; Brown, D.; Hardekopf, R.; Bilskie, J.R.; van Dyck, O.B.V.

    1985-01-01

    An economical harp multiplexer system has been developed to achieve a wide dynamic range. The harp system incorporates a pneumatically actuated harp detector with ceramic boards and carbon wires; a high-sensitivity multiplexer packaged in a double-wide NIM module; and flat, shielded ribbon cable consisting of individual twisted pairs. The system multiplexes 30 wires in each of the x and y planes simultaneously and operates with or without computer control. The system has operated in beams of 100 nA to 1 mA, 1- to 120-Hz repetition rate, with a signal-to-noise ratio of greater than 10/1

  2. High speed, wide dynamic range analog signal processing for avalanche photodiode

    CERN Document Server

    Walder, J P; Pangaud, P

    2000-01-01

    A wide dynamic range multi-gain analog transimpedance amplifier integrated circuit has been developed for avalanche photodiode signal processing. The 96 dB input dynamic range is divided into four ranges of 12-bits each in order to provide 40 MHz analog sampled data to a 12-bits ADC. This concept which has been integrated in both BiCMOS and full complementary bipolar technology along with fitted design techniques will be presented.

  3. High speed, wide dynamic range analog signal processing for avalanche photodiode

    International Nuclear Information System (INIS)

    Walder, J.P.; El Mamouni, Houmani; Pangaud, Patrick

    2000-01-01

    A wide dynamic range multi-gain analog transimpedance amplifier integrated circuit has been developed for avalanche photodiode signal processing. The 96 dB input dynamic range is divided into four ranges of 12-bits each in order to provide 40 MHz analog sampled data to a 12-bits ADC. This concept which has been integrated in both BiCMOS and full complementary bipolar technology along with fitted design techniques will be presented

  4. High speed, wide dynamic range analog signal processing for avalanche photodiode

    Energy Technology Data Exchange (ETDEWEB)

    Walder, J.P. E-mail: walder@in2p3.fr; El Mamouni, Houmani; Pangaud, Patrick

    2000-03-11

    A wide dynamic range multi-gain analog transimpedance amplifier integrated circuit has been developed for avalanche photodiode signal processing. The 96 dB input dynamic range is divided into four ranges of 12-bits each in order to provide 40 MHz analog sampled data to a 12-bits ADC. This concept which has been integrated in both BiCMOS and full complementary bipolar technology along with fitted design techniques will be presented.

  5. A high speed, wide dynamic range digitizer circuit for photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Yarema, R.J.; Foster, G.W.; Knickerbocker, K.; Sarraj, M.; Tschirhart, R.; Whitmore, J.; Zimmerman, T. [Fermi National Accelerator Lab., Batavia, IL (United States); Lindgren, M. [Univ. of California, Los Angeles, CA (United States). Physics Dept.

    1994-06-01

    High energy physics experiments running at high interaction rates frequently require long record lengths for determining a level 1 trigger. The easiest way to provide a long event record is by digital means. In applications requiring wide dynamic range, however, digitization of an analog signal to obtain the digital record has been impossible due to lack of high speed, wide range FADCs. One such application is the readout of thousands of photomultiplier tubes in fixed target and colliding beam experiment calorimeters. A circuit has been designed for digitizing PMT signals over a wide dynamic range (17--18 bits) with 8 bits of resolution at rates up to 53 MHz. Output from the circuit is in a floating point format with a 4 bit exponent and an 8 bit mantissa. The heart of the circuit is a full custom integrated circuit called the QIE (Charge Integrator and Encoder). The design of the QIE and associated circuitry reported here permits operation over a 17 bit dynamic range. Tests of the circuit with a PMT input and a pulsed laser have provided respectable results with little off line correction. Performance of the circuit for demanding applications can be significantly enhanced with additional off line correction. Circuit design, packaging issues, and test results of a multirange device are presented for the first time.

  6. A high speed, wide dynamic range digitizer circuit for photomultiplier tubes

    International Nuclear Information System (INIS)

    Yarema, R.J.; Foster, G.W.; Knickerbocker, K.; Sarraj, M.; Tschirhart, R.; Whitmore, J.; Zimmerman, T.; Lindgren, M.

    1994-06-01

    High energy physics experiments running at high interaction rates frequently require long record lengths for determining a level 1 trigger. The easiest way to provide a long event record is by digital means. In applications requiring wide dynamic range, however, digitization of an analog signal to obtain the digital record has been impossible due to lack of high speed, wide range FADCs. One such application is the readout of thousands of photomultiplier tubes in fixed target and colliding beam experiment calorimeters. A circuit has been designed for digitizing PMT signals over a wide dynamic range (17--18 bits) with 8 bits of resolution at rates up to 53 MHz. Output from the circuit is in a floating point format with a 4 bit exponent and an 8 bit mantissa. The heart of the circuit is a full custom integrated circuit called the QIE (Charge Integrator and Encoder). The design of the QIE and associated circuitry reported here permits operation over a 17 bit dynamic range. Tests of the circuit with a PMT input and a pulsed laser have provided respectable results with little off line correction. Performance of the circuit for demanding applications can be significantly enhanced with additional off line correction. Circuit design, packaging issues, and test results of a multirange device are presented for the first time

  7. Multi-input wide dynamic range ADC system for use with nuclear detectors

    Energy Technology Data Exchange (ETDEWEB)

    Austin, R W [National Aeronautics and Space Administration, Huntsville, Ala. (USA). George C. Marshall Space Flight Center

    1976-04-15

    A wide dynamic range, eight input analog-to-digital converter system has been developed for use in nuclear experiments. The system consists of eight dual-range sample and hold modules, an eight input multiplexer, a ten-bit analog-to-digital converter, and the associated control logic.

  8. A high speed, wide dynamic range digitizer circuit for photomultiplier tubes

    International Nuclear Information System (INIS)

    Yarema, R.J.; Foster, G.W.; Knickerbocker, K.; Sarraj, M.; Tschirhart, R.; Whitmore, J.; Zimmerman, T.; Lindgren, M.

    1995-01-01

    A circuit has been designed for digitizing PMT signals over a wide dynamic range (17-18 bits) with 8 bits of resolution at rates up to 53 MHz. Output from the circuit is in a floating point format with a 4 bit exponent and an 8 bit mantissa. The heart of the circuit is a full custom integrated circuit called the QIE (Charge Integrator and Encoder). The design of the QIE and associated circuitry reported here permits operation over a 17 bit dynamic range. Test results of a multirange device are presented for the first time. (orig.)

  9. Dynamics of intrinsic electrophysiological properties in spinal cord neurones

    DEFF Research Database (Denmark)

    Russo, R E; Hounsgaard, J

    1999-01-01

    The spinal cord is engaged in a wide variety of functions including generation of motor acts, coding of sensory information and autonomic control. The intrinsic electrophysiological properties of spinal neurones represent a fundamental building block of the spinal circuits executing these tasks. ....... Specialised, cell specific electrophysiological phenotypes gradually differentiate during development and are continuously adjusted in the adult animal by metabotropic synaptic interactions and activity-dependent plasticity to meet a broad range of functional demands....

  10. A high linearity current mode multiplier/divider with a wide dynamic range

    International Nuclear Information System (INIS)

    Liao Pengfei; Luo Ping; Zhang Bo; Li Zhaoji

    2012-01-01

    A high linearity current mode multiplier/divider (CMM/D) with a wide dynamic range is presented. The proposed CMM/D is based on the voltage—current characteristic of the diode, thus wide dynamic range is achieved. In addition, high linearity is achieved because high accuracy current mirrors are adopted and the output current is insensitive to the temperature and device parameters of the fabrication process. Furthermore, no extra bias current for all input signals is required and thus power saving is realized. With proper selection of establishing the input terminal, the proposed circuit can perform as a multifunction circuit to be operated as a multiplier/divider, without changing its topology. The proposed circuit is implemented in a 0.25 μm BCD process and the chip area is 0.26 × 0.24 mm 2 . The simulation and measurement results show that the maximum static linearity error is ±1.8% and the total harmonic distortion is 0.4% while the input current ranges from 0 to 200 μA. (semiconductor integrated circuits)

  11. Lithium-ion battery dynamic model for wide range of operating conditions

    DEFF Research Database (Denmark)

    Stroe, Ana-Irina; Stroe, Daniel-Ioan; Swierczynski, Maciej Jozef

    2017-01-01

    In order to analyze the dynamic behavior of a Lithium-ion (Li-ion) battery and to determine their suitability for various applications, battery models are needed. An equivalent electrical circuit model is the most common way of representing the behavior of a Li-ion battery. There are different...... characterization tests performed for a wide range of operating conditions (temperature, load current and state-of-charge) on a commercial available 13Ah high-power lithium titanate oxide battery cell. The obtained results were used to parametrize the proposed dynamic model of the battery cell. To assess...

  12. A high gain wide dynamic range transimpedance amplifier for optical receivers

    International Nuclear Information System (INIS)

    Liu Lianxi; Zou Jiao; Liu Shubin; Niu Yue; Zhu Zhangming; Yang Yintang; En Yunfei

    2014-01-01

    As the front-end preamplifiers in optical receivers, transimpedance amplifiers (TIAs) are commonly required to have a high gain and low input noise to amplify the weak and susceptible input signal. At the same time, the TIAs should possess a wide dynamic range (DR) to prevent the circuit from becoming saturated by high input currents. Based on the above, this paper presents a CMOS transimpedance amplifier with high gain and a wide DR for 2.5 Gbit/s communications. The TIA proposed consists of a three-stage cascade pull push inverter, an automatic gain control circuit, and a shunt transistor controlled by the resistive divider. The inductive-series peaking technique is used to further extend the bandwidth. The TIA proposed displays a maximum transimpedance gain of 88.3 dBΩ with the −3 dB bandwidth of 1.8 GHz, exhibits an input current dynamic range from 100 nA to 10 mA. The output voltage noise is less than 48.23 nV/√Hz within the −3 dB bandwidth. The circuit is fabricated using an SMIC 0.18 μm 1P6M RFCMOS process and dissipates a dc power of 9.4 mW with 1.8 V supply voltage. (semiconductor integrated circuits)

  13. Automatic Generation of Wide Dynamic Range Image without Pseudo-Edge Using Integration of Multi-Steps Exposure Images

    Science.gov (United States)

    Migiyama, Go; Sugimura, Atsuhiko; Osa, Atsushi; Miike, Hidetoshi

    Recently, digital cameras are offering technical advantages rapidly. However, the shot image is different from the sight image generated when that scenery is seen with the naked eye. There are blown-out highlights and crushed blacks in the image that photographed the scenery of wide dynamic range. The problems are hardly generated in the sight image. These are contributory cause of difference between the shot image and the sight image. Blown-out highlights and crushed blacks are caused by the difference of dynamic range between the image sensor installed in a digital camera such as CCD and CMOS and the human visual system. Dynamic range of the shot image is narrower than dynamic range of the sight image. In order to solve the problem, we propose an automatic method to decide an effective exposure range in superposition of edges. We integrate multi-step exposure images using the method. In addition, we try to erase pseudo-edges using the process to blend exposure values. Afterwards, we get a pseudo wide dynamic range image automatically.

  14. The effect of spinal manipulative therapy on spinal range of motion

    DEFF Research Database (Denmark)

    Millan, Mario; Leboeuf-Yde, Charlotte; Budgell, Brian

    2012-01-01

    Spinal manipulative therapy (SMT) has been shown to have an effect on spine-related pain, both clinically and in experimentally induced pain. However, it is unclear if it has an immediate noticeable biomechanical effect on spinal motion that can be measured in terms of an increased range of motion...

  15. High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera Tracking

    Science.gov (United States)

    Liss, J.; Dunagan, S. E.; Johnson, R. R.; Chang, C. S.; LeBlanc, S. E.; Shinozuka, Y.; Redemann, J.; Flynn, C. J.; Segal-Rosenhaimer, M.; Pistone, K.; Kacenelenbogen, M. S.; Fahey, L.

    2016-12-01

    High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera TrackingThe NASA Ames Sun-photometer-Satellite Group, DOE, PNNL Atmospheric Sciences and Global Change Division, and NASA Goddard's AERONET (AErosol RObotic NETwork) team recently collaborated on the development of a new airborne sunphotometry instrument that provides information on gases and aerosols extending far beyond what can be derived from discrete-channel direct-beam measurements, while preserving or enhancing many of the desirable AATS features (e.g., compactness, versatility, automation, reliability). The enhanced instrument combines the sun-tracking ability of the current 14-Channel NASA Ames AATS-14 with the sky-scanning ability of the ground-based AERONET Sun/sky photometers, while extending both AATS-14 and AERONET capabilities by providing full spectral information from the UV (350 nm) to the SWIR (1,700 nm). Strengths of this measurement approach include many more wavelengths (isolated from gas absorption features) that may be used to characterize aerosols and detailed (oversampled) measurements of the absorption features of specific gas constituents. The Sky Scanning Sun Tracking Airborne Radiometer (3STAR) replicates the radiometer functionality of the AATS-14 instrument but incorporates modern COTS technologies for all instruments subsystems. A 19-channel radiometer bundle design is borrowed from a commercial water column radiance instrument manufactured by Biospherical Instruments of San Diego California (ref, Morrow and Hooker)) and developed using NASA funds under the Small Business Innovative Research (SBIR) program. The 3STAR design also incorporates the latest in robotic motor technology embodied in Rotary actuators from Oriental motor Corp. having better than 15 arc seconds of positioning accuracy. Control system was designed, tested and simulated using a Hybrid-Dynamical modeling methodology. The design also replaces the classic quadrant detector tracking sensor with a

  16. An operating principle of the turtle utricle to detect wide dynamic range.

    Science.gov (United States)

    Nam, Jong-Hoon

    2018-03-01

    The utricle encodes both static information such as head orientation, and dynamic information such as vibrations. It is not well understood how the utricle can encode both static and dynamic information for a wide dynamic range (from 2 times the gravitational acceleration; from DC to > 1000 Hz vibrations). Using computational models of the hair cells in the turtle utricle, this study presents an explanation on how the turtle utricle encodes stimulations over such a wide dynamic range. Two hair bundles were modeled using the finite element method-one representing the striolar hair cell (Cell S), and the other representing the medial extrastriolar hair cell (Cell E). A mechano-transduction (MET) channel model was incorporated to compute MET current (i MET ) due to hair bundle deflection. A macro-mechanical model of the utricle was used to compute otoconial motions from head accelerations (a Head ). According to known anatomical data, Cell E has a long kinocilium that is embedded into the stiff otoconial layer. Unlike Cell E, the hair bundle of Cell S falls short of the otoconial layer. Considering such difference in the mechanical connectivity between the hair cell bundle and the otoconial layer, three cases were simulated: Cell E displacement-clamped, Cell S viscously-coupled, and Cell S displacement-clamped. Head accelerations at different amplitude levels and different frequencies were simulated for the three cases. When a realistic head motion was simulated, Cell E was responsive to head orientation, while the viscously-coupled Cell S was responsive to fast head motion imitating the feeding strike of a turtle. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Logarithmic circuit with wide dynamic range

    Science.gov (United States)

    Wiley, P. H.; Manus, E. A. (Inventor)

    1978-01-01

    A circuit deriving an output voltage that is proportional to the logarithm of a dc input voltage susceptible to wide variations in amplitude includes a constant current source which forward biases a diode so that the diode operates in the exponential portion of its voltage versus current characteristic, above its saturation current. The constant current source includes first and second, cascaded feedback, dc operational amplifiers connected in negative feedback circuit. An input terminal of the first amplifier is responsive to the input voltage. A circuit shunting the first amplifier output terminal includes a resistor in series with the diode. The voltage across the resistor is sensed at the input of the second dc operational feedback amplifier. The current flowing through the resistor is proportional to the input voltage over the wide range of variations in amplitude of the input voltage.

  18. A wide dynamic range BF3 neutron monitor with front-end electronics based on a logarithmic amplifier

    International Nuclear Information System (INIS)

    Ferrarini, M.; Varoli, V.; Favalli, A.; Caresana, M.; Pedersen, B.

    2010-01-01

    This paper describes a wide dynamic range neutron monitor based on a BF 3 neutron detector. The detector is used in current mode, and front-end electronics based on a logarithmic amplifier are used in order to have a measurement capability ranging over many orders of magnitude. The system has been calibrated at the Polytechnic of Milan, CESNEF, with an AmBe neutron source, and has been tested in a pulsed field at the PUNITA facility at JRC, Ispra. The detector has achieved a dynamic range of over 6 orders of magnitude, being able to measure single neutron pulses and showing saturation-free response for a reaction rate up to 10 6 s -1 . It has also proved effective in measuring the PUNITA facility pulse integral fluence.

  19. Wide-spectral/dynamic-range skin-compatible phototransistors enabled by floated heterojunction structures with surface functionalized SWCNTs and amorphous oxide semiconductors.

    Science.gov (United States)

    Hwang, Insik; Kim, Jaehyun; Lee, Minkyung; Lee, Min-Wook; Kim, Hee-Joong; Kwon, Hyuck-In; Hwang, Do Kyung; Kim, Myunggil; Yoon, Haeyoung; Kim, Yong-Hoon; Park, Sung Kyu

    2017-11-09

    Purified semiconducting single-walled carbon nanotubes (sc-SWCNTs) have been researched for optoelectronic applications due to their high absorption coefficient from the visible to even the near-infrared (NIR) region. Nevertheless, the insufficient electrical characteristics and incompatibility with conventional CMOS processing have limited their wide utilization in this emerging field. Here, we demonstrate highly detective and wide spectral/dynamic range phototransistors incorporating floated heterojunction active layers which are composed of low-temperature sol-gel processed n-type amorphous indium gallium zinc oxide (a-IGZO) stacked with a purified p-type sc-SWCNT layer. To achieve a high and broad spectral/dynamic range photo-response of the heterogeneous transistors, photochemically functionalized sc-SWCNT layers were carefully implemented onto the a-IGZO channel area with a floating p-n heterojunction active layer, resulting in the suppression of parasitic charge leakage and good bias driven opto-electrical properties. The highest photosensitivity (R) of 9.6 × 10 2 A W -1 and a photodetectivity (D*) of 4 × 10 14 Jones along with a dynamic range of 100-180 dB were achieved for our phototransistor in the spectral range of 400-780 nm including continuous and minimal frequency independent behaviors. More importantly, to demonstrate the diverse application of the ultra-flexible hybrid photosensor platform as skin compatible electronics, the sc-SWCNT/a-IGZO phototransistors were fabricated on an ultra-thin (∼1 μm) polyimide film along with a severe static and dynamic electro-mechanical test. The skin-like phototransistors showed excellent mechanical stability such as sustainable good electrical performance and high photosensitivity in a wide dynamic range without any visible cracks or damage and little noise interference after being rolled-up on the 150 μm-thick optical fiber as well as more than 1000 times cycling.

  20. Intelligibility and Clarity of Reverberant Speech: Effects of Wide Dynamic Range Compression Release Time and Working Memory

    Science.gov (United States)

    Reinhart, Paul N.; Souza, Pamela E.

    2016-01-01

    Purpose: The purpose of this study was to examine the effects of varying wide dynamic range compression (WDRC) release time on intelligibility and clarity of reverberant speech. The study also considered the role of individual working memory. Method: Thirty older listeners with mild to moderately-severe sloping sensorineural hearing loss…

  1. THE EFFECTS OF BACK EXTENSION TRAINING ON BACK MUSCLE STRENGTH AND SPINAL RANGE OF MOTION IN YOUNG FEMALES

    Directory of Open Access Journals (Sweden)

    Yıldız Yaprak

    2013-04-01

    Full Text Available The objective of this study was to determine the effects of a 10-week dynamic back extension training programme and its effects on back muscle strength, back muscle endurance and spinal range of motion (ROM for healthy young females. Seventy-three young females (age: 19.32±1.80 years, height: 158.89±4.71 cm, body weight: 55.67±6.30 kg volunteered for the study. Prior to the training period, all participants completed anthropometric measurements, back muscle strength and endurance test, lateral bending and spinal ROM measurements. After measurements, the participants were divided into two groups. The exercise group (N:35 performed the dynamic back extension exercise 3 days per week for 10 weeks. The control group (N:38 did not participate in any type of exercise. The mixed design ANOVA (group x time was used to determine the difference in pre- and post-training values. The present findings show that there were significant differences between pre-training and post-training values for back muscle strength and spinal ROM in the exercise group. Following the dynamic strength training programme, back muscle strength and spine ROM values except flexion of the lumbar 5-sacrum 1 (L5-S1 segment of the exercise group showed a significant increase when compared with the pre test values. The control group did not show any significant changes when compared with the pre-training values. The results demonstrate that the 10-week dynamic strength training programme was effective for spinal extension ROM and back muscle strength, but there was no change in back muscle endurance. In this context, this programme could potentially be used to prevent the decrease of spinal ROM as well as provide an increase in the fitness parameters of healthy individuals.

  2. Nonlinear dynamic range transformation in visual communication channels.

    Science.gov (United States)

    Alter-Gartenberg, R

    1996-01-01

    The article evaluates nonlinear dynamic range transformation in the context of the end-to-end continuous-input/discrete processing/continuous-display imaging process. Dynamic range transformation is required when we have the following: (i) the wide dynamic range encountered in nature is compressed into the relatively narrow dynamic range of the display, particularly for spatially varying irradiance (e.g., shadow); (ii) coarse quantization is expanded to the wider dynamic range of the display; and (iii) nonlinear tone scale transformation compensates for the correction in the camera amplifier.

  3. A wide dynamic range BF{sub 3} neutron monitor with front-end electronics based on a logarithmic amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Ferrarini, M., E-mail: michele.ferrarini@polimi.i [Politecnico di Milano, Dipartimento Energia, via G. Ponzio 34/3, I-20133 Milano (Italy); Fondazione CNAO, via Caminadella 16, 20123 Milano (Italy); Varoli, V. [Politecnico di Milano, Dipartimento Energia, via G. Ponzio 34/3, I-20133 Milano (Italy); Favalli, A. [European Commission, Joint Research Centre, Institute for the Protection and Security of Citizen, TP 800, Via E. Fermi, 21027 Ispra (Vatican City State, Holy See) (Italy); Caresana, M. [Politecnico di Milano, Dipartimento Energia, via G. Ponzio 34/3, I-20133 Milano (Italy); Pedersen, B. [European Commission, Joint Research Centre, Institute for the Protection and Security of Citizen, TP 800, Via E. Fermi, 21027 Ispra (Italy)

    2010-02-01

    This paper describes a wide dynamic range neutron monitor based on a BF{sub 3} neutron detector. The detector is used in current mode, and front-end electronics based on a logarithmic amplifier are used in order to have a measurement capability ranging over many orders of magnitude. The system has been calibrated at the Polytechnic of Milan, CESNEF, with an AmBe neutron source, and has been tested in a pulsed field at the PUNITA facility at JRC, Ispra. The detector has achieved a dynamic range of over 6 orders of magnitude, being able to measure single neutron pulses and showing saturation-free response for a reaction rate up to 10{sup 6} s{sup -1}. It has also proved effective in measuring the PUNITA facility pulse integral fluence.

  4. Fast negative feedback enables mammalian auditory nerve fibers to encode a wide dynamic range of sound intensities.

    Directory of Open Access Journals (Sweden)

    Mark Ospeck

    Full Text Available Mammalian auditory nerve fibers (ANF are remarkable for being able to encode a 40 dB, or hundred fold, range of sound pressure levels into their firing rate. Most of the fibers are very sensitive and raise their quiescent spike rate by a small amount for a faint sound at auditory threshold. Then as the sound intensity is increased, they slowly increase their spike rate, with some fibers going up as high as ∼300 Hz. In this way mammals are able to combine sensitivity and wide dynamic range. They are also able to discern sounds embedded within background noise. ANF receive efferent feedback, which suggests that the fibers are readjusted according to the background noise in order to maximize the information content of their auditory spike trains. Inner hair cells activate currents in the unmyelinated distal dendrites of ANF where sound intensity is rate-coded into action potentials. We model this spike generator compartment as an attenuator that employs fast negative feedback. Input current induces rapid and proportional leak currents. This way ANF are able to have a linear frequency to input current (f-I curve that has a wide dynamic range. The ANF spike generator remains very sensitive to threshold currents, but efferent feedback is able to lower its gain in response to noise.

  5. Particle identification in a wide dynamic range based on pulse-shape analysis with solid-state detectors

    International Nuclear Information System (INIS)

    Pausch, G.; Hilscher, D.; Ortlepp, H.G.

    1994-04-01

    Heavy ions detected in a planar silicon detector were identified by exploiting a recently proposed combination of the pulse-shape and the time-of-flight techniques. We were able to resolve charge numbers up to Z = 16 within a wide dynamic range of ∼ 1:5, and to identify even isotopes for the elements up to Magnesium. The simple scheme of signal processing is based on conventional electronics and cheap enough to be exploited in large multidetector arrays. (orig.)

  6. Ultrafast dynamic computed tomography myelography for the precise identification of high-flow cerebrospinal fluid leaks caused by spiculated spinal osteophytes.

    Science.gov (United States)

    Thielen, Kent R; Sillery, John C; Morris, Jonathan M; Hoxworth, Joseph M; Diehn, Felix E; Wald, John T; Rosebrock, Richard E; Yu, Lifeng; Luetmer, Patrick H

    2015-03-01

    Precise localization and understanding of the origin of spontaneous high-flow spinal CSF leaks is required prior to targeted treatment. This study demonstrates the utility of ultrafast dynamic CT myelography for the precise localization of high-flow CSF leaks caused by spiculated spinal osteophytes. This study reports a series of 14 patients with high-flow CSF leaks caused by spiculated spinal osteophytes who underwent ultrafast dynamic CT myelography between March 2009 and December 2010. There were 10 male and 4 female patients, with an average age of 49 years (range 37-74 years). The value of ultrafast dynamic CT myelography in depicting the CSF leak site was qualitatively assessed. In all 14 patients, ultrafast dynamic CT myelography was technically successful at precisely demonstrating the site of the CSF leak, the causative spiculated osteophyte piercing the dura, and the relationship of the implicated osteophyte to adjacent structures. Leak sites included 3 cervical, 11 thoracic, and 0 lumbar levels, with 86% of the leaks occurring from C-5 to T-7. Information obtained from the ultrafast dynamic CT myelogram was considered useful in all treated CSF leaks. Spinal osteophytes piercing the dura are a more frequent cause of high-flow CSF leaks than previously recognized. Ultrafast dynamic CT myelography adds value beyond standard dynamic myelography or digital subtraction myelography in the diagnosis and anatomical characterization of high-flow spinal CSF leaks caused by these osteophytes. This information allows for appropriate planning for percutaneous or surgical treatment.

  7. ATMOSPHERIC DYNAMICS OF TERRESTRIAL EXOPLANETS OVER A WIDE RANGE OF ORBITAL AND ATMOSPHERIC PARAMETERS

    Energy Technology Data Exchange (ETDEWEB)

    Kaspi, Yohai [Department of Earth and Planetary Sciences, Weizmann Institute of Science, 234 Herzl st., 76100, Rehovot (Israel); Showman, Adam P., E-mail: yohai.kaspi@weizmann.ac.il [Department of Planetary Sciences and Lunar and Planetary Laboratory, The University of Arizona, 1629 University Blvd., Tucson, AZ 85721 (United States)

    2015-05-01

    The recent discoveries of terrestrial exoplanets and super-Earths extending over a broad range of orbital and physical parameters suggest that these planets will span a wide range of climatic regimes. Characterization of the atmospheres of warm super-Earths has already begun and will be extended to smaller and more distant planets over the coming decade. The habitability of these worlds may be strongly affected by their three-dimensional atmospheric circulation regimes, since the global climate feedbacks that control the inner and outer edges of the habitable zone—including transitions to Snowball-like states and runaway-greenhouse feedbacks—depend on the equator-to-pole temperature differences, patterns of relative humidity, and other aspects of the dynamics. Here, using an idealized moist atmospheric general circulation model including a hydrological cycle, we study the dynamical principles governing the atmospheric dynamics on such planets. We show how the planetary rotation rate, stellar flux, atmospheric mass, surface gravity, optical thickness, and planetary radius affect the atmospheric circulation and temperature distribution on such planets. Our simulations demonstrate that equator-to-pole temperature differences, meridional heat transport rates, structure and strength of the winds, and the hydrological cycle vary strongly with these parameters, implying that the sensitivity of the planet to global climate feedbacks will depend significantly on the atmospheric circulation. We elucidate the possible climatic regimes and diagnose the mechanisms controlling the formation of atmospheric jet streams, Hadley and Ferrel cells, and latitudinal temperature differences. Finally, we discuss the implications for understanding how the atmospheric circulation influences the global climate.

  8. ATMOSPHERIC DYNAMICS OF TERRESTRIAL EXOPLANETS OVER A WIDE RANGE OF ORBITAL AND ATMOSPHERIC PARAMETERS

    International Nuclear Information System (INIS)

    Kaspi, Yohai; Showman, Adam P.

    2015-01-01

    The recent discoveries of terrestrial exoplanets and super-Earths extending over a broad range of orbital and physical parameters suggest that these planets will span a wide range of climatic regimes. Characterization of the atmospheres of warm super-Earths has already begun and will be extended to smaller and more distant planets over the coming decade. The habitability of these worlds may be strongly affected by their three-dimensional atmospheric circulation regimes, since the global climate feedbacks that control the inner and outer edges of the habitable zone—including transitions to Snowball-like states and runaway-greenhouse feedbacks—depend on the equator-to-pole temperature differences, patterns of relative humidity, and other aspects of the dynamics. Here, using an idealized moist atmospheric general circulation model including a hydrological cycle, we study the dynamical principles governing the atmospheric dynamics on such planets. We show how the planetary rotation rate, stellar flux, atmospheric mass, surface gravity, optical thickness, and planetary radius affect the atmospheric circulation and temperature distribution on such planets. Our simulations demonstrate that equator-to-pole temperature differences, meridional heat transport rates, structure and strength of the winds, and the hydrological cycle vary strongly with these parameters, implying that the sensitivity of the planet to global climate feedbacks will depend significantly on the atmospheric circulation. We elucidate the possible climatic regimes and diagnose the mechanisms controlling the formation of atmospheric jet streams, Hadley and Ferrel cells, and latitudinal temperature differences. Finally, we discuss the implications for understanding how the atmospheric circulation influences the global climate

  9. Wide Dynamic Range Multiband Infrared Radiometer for In-Fire Measurements of Wildland Fire Radiant Flux Density

    Science.gov (United States)

    Kremens, R.; Dickinson, M. B.; Hardy, C.; Skowronski, N.; Ellicott, E. A.; Schroeder, W.

    2016-12-01

    We have developed a wide dynamic range (24-bit) data acquisition system for collection of radiant flux density (FRFD) data from wildland fires. The data collection subsystem was designed as an Arduino `shield' and incorporates a 24-bit analog-to-digital converter, precision voltage reference, real time clock, microSD card interface, audible annuciator and interface for various digital communication interfaces (RS232, I2C, SPI, etc.). The complete radiometer system consists of our custom-designed `shield', a commercially available Arduino MEGA computer circuit board and a thermopile sensor -amplifier daughter board. Software design and development is greatly assisted by the availability of a library of public-domain, user-implemented software. The daughter board houses a 5-band radiometer using thermopiles designed for this experiment (Dexter Research Corp., Dexter, MI) to allow determination of the total FRFD from the fire (using a wide band thermopile with a KRS-5 window, 0.1 - 30 um), the FRFD as would be received by an orbital asset like MODIS (3.95 um center wavelength (CWL) and 10.95 CWL, corresponding to MODIS bands 21/22 and 31, respectively) and wider bandpass (0.1-5.5 um and 8-14 um) corresponding to the FRFD recorded by `MWIR' and `LWIR' imaging systems. We required a very wide dynamic range system in order to be able to record the flux density from `cold' ground before the fire, through the `hot' flaming combustion stage, to the `cool' phase after passage of the fire front. The recording dynamic range required (with reasonable resolution at the lowest temperatures) is on the order of 106, which is not currently available in commercial instrumentation at a price point, size or feature set that is suitable for wildland fire investigations. The entire unit, along with rechargeable battery power supply is housed in a fireproof aluminum chassis box, which is then mounted on a mast at a height of 5 - 7 m above the fireground floor. We will report initial

  10. A wide-range model of two-group gross sections in the dynamics code HEXTRAN

    International Nuclear Information System (INIS)

    Kaloinen, E.; Peltonen, J.

    2002-01-01

    In dynamic analyses the thermal hydraulic conditions within the reactor core may have a large variation, which sets a special requirement on the modeling of cross sections. The standard model in the dynamics code HEXTRAN is the same as in the static design code HEXBU-3D/MODS. It is based on a linear and second order fitting of two-group cross sections on fuel and moderator temperature, moderator density and boron density. A new, wide-range model of cross sections developed in Fortum Nuclear Services for HEXBU-3D/MOD6 has been included as an option into HEXTRAN. In this model the nodal cross sections are constructed from seven state variables in a polynomial of more than 40 terms. Coefficients of the polynomial are created by a least squares fitting to the results of a large number of fuel assembly calculations. Depending on the choice of state variables for the spectrum calculations, the new cross section model is capable to cover local conditions from cold zero power to boiling at full power. The 5. dynamic benchmark problem of AER is analyzed with the new option and results are compared to calculations with the standard model of cross sections in HEXTRAN (Authors)

  11. Screening variability and change of soil moisture under wide-ranging climate conditions: Snow dynamics effects.

    Science.gov (United States)

    Verrot, Lucile; Destouni, Georgia

    2015-01-01

    Soil moisture influences and is influenced by water, climate, and ecosystem conditions, affecting associated ecosystem services in the landscape. This paper couples snow storage-melting dynamics with an analytical modeling approach to screening basin-scale, long-term soil moisture variability and change in a changing climate. This coupling enables assessment of both spatial differences and temporal changes across a wide range of hydro-climatic conditions. Model application is exemplified for two major Swedish hydrological basins, Norrström and Piteälven. These are located along a steep temperature gradient and have experienced different hydro-climatic changes over the time period of study, 1950-2009. Spatially, average intra-annual variability of soil moisture differs considerably between the basins due to their temperature-related differences in snow dynamics. With regard to temporal change, the long-term average state and intra-annual variability of soil moisture have not changed much, while inter-annual variability has changed considerably in response to hydro-climatic changes experienced so far in each basin.

  12. Development of wide range charge integration application specified integrated circuit for photo-sensor

    Energy Technology Data Exchange (ETDEWEB)

    Katayose, Yusaku, E-mail: katayose@ynu.ac.jp [Department of Physics, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa 240-8501 (Japan); Ikeda, Hirokazu [Institute of Space and Astronautical Science (ISAS)/Japan Aerospace Exploration Agency (JAXA), 3-1-1 Yoshinodai, Chuo-ku, Sagamihara, Kanagawa 252-5210 (Japan); Tanaka, Manobu [National Laboratory for High Energy Physics, KEK, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Shibata, Makio [Department of Physics, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama, Kanagawa 240-8501 (Japan)

    2013-01-21

    A front-end application specified integrated circuit (ASIC) is developed with a wide dynamic range amplifier (WDAMP) to read-out signals from a photo-sensor like a photodiode. The WDAMP ASIC consists of a charge sensitive preamplifier, four wave-shaping circuits with different amplification factors and Wilkinson-type analog-to-digital converter (ADC). To realize a wider range, the integrating capacitor in the preamplifier can be changed from 4 pF to 16 pF by a two-bit switch. The output of a preamplifier is shared by the four wave-shaping circuits with four gains of 1, 4, 16 and 64 to adapt the input range of ADC. A 0.25-μm CMOS process (of UMC electronics CO., LTD) is used to fabricate the ASIC with four-channels. The dynamic range of four orders of magnitude is achieved with the maximum range over 20 pC and the noise performance of 0.46 fC + 6.4×10{sup −4} fC/pF. -- Highlights: ► A front-end ASIC is developed with a wide dynamic range amplifier. ► The ASIC consists of a CSA, four wave-shaping circuits and pulse-height-to-time converters. ► The dynamic range of four orders of magnitude is achieved with the maximum range over 20 pC.

  13. Characterization of a wide dynamic-range, radiation-tolerant charge-digitizer asic for monitoring of Beam losses

    CERN Document Server

    Guido Venturini, G G; Dehning, B; Kayal, M

    2012-01-01

    An Application Specific Integrated Circuit (ASIC) has been designed and fabricated to provide a compact solution to digitize current signals from ionization chambers and diamond detectors, employed as beam loss monitors at CERN and several other high energy physics facilities. The circuit topology has been devised to accept positive and negative currents, to have a wide dynamic range (above 120 dB), withstand radiation levels over 10 Mrad and offer different modes of operation, covering a broad range of applications. Furthermore, an internal conversion reference is employed in the digitization, to provide an accurate absolute measurement. This paper discusses the detailed characterization of the first prototype: linearity, radiation tolerance and temperature dependence of the conversion, as well as implications and system-level considerations regarding its use for beam instrumentation applications in a high energy physics facility.

  14. A wide range and high speed automatic gain control

    International Nuclear Information System (INIS)

    Tacconi, E.; Christiansen, C.

    1993-05-01

    Automatic gain control (AGC) techniques have been largely used since the beginning of electronics, but in most of the applications the dynamic response is slow compared with the carrier frequency. The problem of developing an automatic gain control with high dynamic response and wide control range simultaneously is analyzed in this work. An ideal gain control law, with the property that the total loop gain remains constant independent of the carrier amplitude, is obtained. The resulting AGC behavior is compared by computer simulations with a linear multiplier AGC. The ideal gain control law can be approximated using a transconductance amplifier. A practical circuit that has been used at CERN in the radio frequency loops of the Booster Synchrotron is presented. The circuit has high speed and 80-dB gain control range

  15. Optimization of nonimaging focusing heliostat in dynamic correction of astigmatism for a wide range of incident angles.

    Science.gov (United States)

    Chong, Kok-Keong

    2010-05-15

    To overcome astigmatism has always been a great challenge in designing a heliostat capable of focusing the sunlight on a small receiver throughout the year. In this Letter, a nonimaging focusing heliostat with a dynamic adjustment of facet mirrors in a group manner has been analyzed for optimizing the astigmatic correction in a wide range of incident angles. This what is to the author's knowledge a new heliostat is not only designed to serve the purpose of concentrating sunlight to several hundreds of suns, but also to significantly reduce the variation of the solar flux distribution with the incident angle.

  16. Directional Wide-Angle Range Finder (DWARF)

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation, the Directional Wide-Angle Range Finder (DWARF) is the creation of a laser range-finder with a wide field-of-view (FOV) and a directional...

  17. Fast, Highly-Sensitive, and Wide-Dynamic-Range Interdigitated Capacitor Glucose Biosensor Using Solvatochromic Dye-Containing Sensing Membrane.

    Science.gov (United States)

    Khan, Md Rajibur Rahaman; Khalilian, Alireza; Kang, Shin-Won

    2016-02-20

    In this paper, we proposed an interdigitated capacitor (IDC)-based glucose biosensor to measure different concentrations of glucose from 1 μM to 1 M. We studied four different types of solvatochromic dyes: Auramine O, Nile red, Rhodamine B, and Reichardt's dye (R-dye). These dyes were individually incorporated into a polymer [polyvinyl chloride (PVC)] and N,N-Dimethylacetamide (DMAC) solution to make the respective dielectric/sensing materials. To the best of our knowledge, we report for the first time an IDC glucose biosensing system utilizing a solvatochromic-dye-containing sensing membrane. These four dielectric or sensing materials were individually placed into the interdigitated electrode (IDE) by spin coating to make four IDC glucose biosensing elements. The proposed IDC glucose biosensor has a high sensing ability over a wide dynamic range and its sensitivity was about 23.32 mV/decade. It also has fast response and recovery times of approximately 7 s and 5 s, respectively, excellent reproducibility with a standard deviation of approximately 0.023, highly stable sensing performance, and real-time monitoring capabilities. The proposed IDC glucose biosensor was compared with an IDC, potentiometric, FET, and fiber-optic glucose sensor with respect to response time, dynamic range width, sensitivity, and linearity. We observed that the designed IDC glucose biosensor offered excellent performance.

  18. Wide-Range Adaptive RF-to-DC Power Converter for UHF RFIDs

    KAUST Repository

    Ouda, Mahmoud H.

    2016-07-27

    A wide-range, differential, cross-coupled rectifier is proposed with an extended dynamic range of input RF power that enables wireless powering from varying distances. The proposed architecture mitigates the reverse-leakage problem in conven- tional, cross-coupled rectifiers without degrading sensitivity. A prototype is designed for UHF RFID applications, and is imple- mented using 0.18 μ m CMOS technology. On-chip measurements demonstrate a sensitivity of − 18 dBm for 1 V output over a 100 k Ω load and a peak RF-to-DC power conversion efficiency of 65%. A conventional, fully cross-coupled rectifier is fabricated along- side for comparison and the proposed rectifier shows more than 2 × increase in dynamic range and a 25% boosting in output voltage than the conventional rectifier

  19. An emittance measurement system for a wide range of bunch charges

    International Nuclear Information System (INIS)

    Dunham, B.; Engwall, D.; Hofler, A.; Keesee, M.; Legg, R.

    1997-01-01

    As a part of the emittance measurements planned for the FEL injector at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), the authors have developed an emittance measurement system that covers the wide dynamic range of bunch charges necessary to fully characterize the high-DC-voltage photocathode gun. The measurements are carried out with a variant of the classical two-slit method using a slit to sample the beam in conjunction with a wire scanner to measure the transmitted beam profile. The use of commercial, ultra-low noise picoammeters makes it possible to cover the wide range of desired bunch charges, with the actual measurements made over the range of 0.25 pC to 125 pC. The entire system, including its integration into the EPICS control system, is discussed

  20. High Dynamic Velocity Range Particle Image Velocimetry Using Multiple Pulse Separation Imaging

    Directory of Open Access Journals (Sweden)

    Tadhg S. O’Donovan

    2010-12-01

    Full Text Available The dynamic velocity range of particle image velocimetry (PIV is determined by the maximum and minimum resolvable particle displacement. Various techniques have extended the dynamic range, however flows with a wide velocity range (e.g., impinging jets still challenge PIV algorithms. A new technique is presented to increase the dynamic velocity range by over an order of magnitude. The multiple pulse separation (MPS technique (i records series of double-frame exposures with different pulse separations, (ii processes the fields using conventional multi-grid algorithms, and (iii yields a composite velocity field with a locally optimized pulse separation. A robust criterion determines the local optimum pulse separation, accounting for correlation strength and measurement uncertainty. Validation experiments are performed in an impinging jet flow, using laser-Doppler velocimetry as reference measurement. The precision of mean flow and turbulence quantities is significantly improved compared to conventional PIV, due to the increase in dynamic range. In a wide range of applications, MPS PIV is a robust approach to increase the dynamic velocity range without restricting the vector evaluation methods.

  1. High dynamic velocity range particle image velocimetry using multiple pulse separation imaging.

    Science.gov (United States)

    Persoons, Tim; O'Donovan, Tadhg S

    2011-01-01

    The dynamic velocity range of particle image velocimetry (PIV) is determined by the maximum and minimum resolvable particle displacement. Various techniques have extended the dynamic range, however flows with a wide velocity range (e.g., impinging jets) still challenge PIV algorithms. A new technique is presented to increase the dynamic velocity range by over an order of magnitude. The multiple pulse separation (MPS) technique (i) records series of double-frame exposures with different pulse separations, (ii) processes the fields using conventional multi-grid algorithms, and (iii) yields a composite velocity field with a locally optimized pulse separation. A robust criterion determines the local optimum pulse separation, accounting for correlation strength and measurement uncertainty. Validation experiments are performed in an impinging jet flow, using laser-Doppler velocimetry as reference measurement. The precision of mean flow and turbulence quantities is significantly improved compared to conventional PIV, due to the increase in dynamic range. In a wide range of applications, MPS PIV is a robust approach to increase the dynamic velocity range without restricting the vector evaluation methods.

  2. Nogo-A expression dynamically varies after spinal cord injury

    Directory of Open Access Journals (Sweden)

    Jian-wei Wang

    2015-01-01

    Full Text Available The mechanism involved in neural regeneration after spinal cord injury is unclear. The myelin-derived protein Nogo-A, which is specific to the central nervous system, has been identified to negatively affect the cytoskeleton and growth program of axotomized neurons. Studies have shown that Nogo-A exerts immediate and chronic inhibitory effects on neurite outgrowth. In vivo, inhibitors of Nogo-A have been shown to lead to a marked enhancement of regenerative axon extension. We established a spinal cord injury model in rats using a free-falling weight drop device to subsequently investigate Nogo-A expression. Nogo-A mRNA and protein expression and immunoreactivity were detected in spinal cord tissue using real-time quantitative PCR, immunohistochemistry and western blot analysis. At 24 hours after spinal cord injury, Nogo-A protein and mRNA expression was low in the injured group compared with control and sham-operated groups. The levels then continued to drop further and were at their lowest at 3 days, rapidly rose to a peak after 7 days, and then gradually declined again after 14 days. These changes were observed at both the mRNA and protein level. The transient decrease observed early after injury followed by high levels for a few days indicates Nogo-A expression is time dependent. This may contribute to the lack of regeneration in the central nervous system after spinal cord injury. The dynamic variation of Nogo-A should be taken into account in the treatment of spinal cord injury.

  3. Fast, Highly-Sensitive, and Wide-Dynamic-Range Interdigitated Capacitor Glucose Biosensor Using Solvatochromic Dye-Containing Sensing Membrane

    Directory of Open Access Journals (Sweden)

    Md. Rajibur Rahaman Khan

    2016-02-01

    Full Text Available In this paper, we proposed an interdigitated capacitor (IDC-based glucose biosensor to measure different concentrations of glucose from 1 μM to 1 M. We studied four different types of solvatochromic dyes: Auramine O, Nile red, Rhodamine B, and Reichardt’s dye (R-dye. These dyes were individually incorporated into a polymer [polyvinyl chloride (PVC] and N,N-Dimethylacetamide (DMAC solution to make the respective dielectric/sensing materials. To the best of our knowledge, we report for the first time an IDC glucose biosensing system utilizing a solvatochromic-dye-containing sensing membrane. These four dielectric or sensing materials were individually placed into the interdigitated electrode (IDE by spin coating to make four IDC glucose biosensing elements. The proposed IDC glucose biosensor has a high sensing ability over a wide dynamic range and its sensitivity was about 23.32 mV/decade. It also has fast response and recovery times of approximately 7 s and 5 s, respectively, excellent reproducibility with a standard deviation of approximately 0.023, highly stable sensing performance, and real-time monitoring capabilities. The proposed IDC glucose biosensor was compared with an IDC, potentiometric, FET, and fiber-optic glucose sensor with respect to response time, dynamic range width, sensitivity, and linearity. We observed that the designed IDC glucose biosensor offered excellent performance.

  4. CFD comparison with centrifugal compressor measurements on a wide operating range

    Directory of Open Access Journals (Sweden)

    Arnou D.

    2013-04-01

    Full Text Available Centrifugal compressors are widely used in industrial applications thanks to their high efficiency. They are able to provide a wide operating range before reaching the flow barrier or surge limits. Performances and range are described by compressor maps obtained experimentally. After a description of performance test rig, this article compares measured centrifugal compressor performances with computational fluid dynamics results. These computations are performed at steady conditions with R134a refrigerant as fluid. Navier-Stokes equations, coupled with k-ε turbulence model, are solved by the commercial software ANSYS-CFX by means of volume finite method. Input conditions are varied in order to calculate several speed lines. Theoretical isentropic efficiency and theoretical surge line are finally compared to experimental data.

  5. Assessment of stability during gait in patients with spinal deformity-A preliminary analysis using the dynamic stability margin.

    Science.gov (United States)

    Simon, Anne-Laure; Lugade, Vipul; Bernhardt, Kathie; Larson, A Noelle; Kaufman, Kenton

    2017-06-01

    Daily living activities are dynamic, requiring spinal motion through space. Current assessment of spinal deformities is based on static measurements from full-spine standing radiographs. Tools to assess dynamic stability during gait might be useful to enhance the standard evaluation. The aim of this study was to evaluate gait dynamic imbalance in patients with spinal deformity using the dynamic stability margin (DSM). Twelve normal subjects and 17 patients with spinal deformity were prospectively recruited. A kinematic 3D gait analysis was performed for the control group (CG) and the spinal deformity group (SDG). The DSM (distance between the extrapolated center of mass and the base of support) and time-distance parameters were calculated for the right and left side during gait. The relationship between DSM and step length was assessed using three variables: gait stability, symmetry, and consistency. Variables' accuracy was validated by a discriminant analysis. Patients with spinal deformity exhibited gait instability according to the DSM (0.25m versus 0.31m) with decreased velocity (1.1ms -1 versus 1.3ms -1 ) and decreased step length (0.32m versus 0.38m). According to the discriminant analysis, gait stability was the more accurate variable (area under the curve AUC=0.98) followed by gait symmetry and consistency. However, gait consistency showed 100% of specificity, sensitivity, and accuracy of precision. The DSM showed that patients with spinal malalignment exhibit decreased gait stability, symmetry, and consistency besides gait time-distance parameter changes. Additional work is required to determine how to apply the DSM for preoperative and postoperative spinal deformity management. Copyright © 2017. Published by Elsevier B.V.

  6. Wide range neutron flux monitor

    International Nuclear Information System (INIS)

    Endo, Yorimasa; Fukushima, Toshiki.

    1983-01-01

    Purpose: To provide a wide range neutron-flux monitor adapted such that the flux monitoring function and alarming function can automatically by shifted from pulse counting system to cambel method system. Constitution: A wide range neutron-flux monitor comprises (la) pulse counting system and (lb) cambel-method system for inputting detection signals from neutron detectors and separating them into signals for the pulse measuring system and the cambel measuring system, (2) overlap detection and calculation circuit for detecting the existence of the overlap of two output signals from the (la) and (lb) systems, and (3) trip circuit for judging the abnormal state of neutron detectors upon input of the detection signals. (Seki, T.)

  7. Repeated touch and needle-prick stimulation in the neonatal period increases the baseline mechanical sensitivity and postinjury hypersensitivity of adult spinal sensory neurons.

    Science.gov (United States)

    van den Hoogen, Nynke J; Patijn, Jacob; Tibboel, Dick; Joosten, Bert A; Fitzgerald, Maria; Kwok, Charlie H T

    2018-03-08

    Noxious stimulation at critical stages of development has long-term consequences on somatosensory processing in later life, but it is not known whether this developmental plasticity is restricted to nociceptive pathways. Here, we investigate the effect of repeated neonatal noxious or innocuous hind paw stimulation on adult spinal dorsal horn cutaneous mechanical sensitivity. Neonatal Sprague-Dawley rats of both sexes received 4 unilateral left hind paw needle pricks (NPs, n = 13) or 4 tactile (cotton swab touch) stimuli, per day (TC, n = 11) for the first 7 days of life. Control pups were left undisturbed (n = 17). When adult (6-8 weeks), lumbar wide-dynamic-range neuron activity in laminae III-V was recorded using in vivo extracellular single-unit electrophysiology. Spike activity evoked by cutaneous dynamic tactile (brush), pinch and punctate (von Frey hair) stimulation, and plantar receptive field areas were recorded, at baseline and 2 and 5 days after left plantar hind paw incision. Baseline brush receptive fields, von Frey hair, and pinch sensitivity were significantly enhanced in adult NP and TC animals compared with undisturbed controls, although effects were greatest in NP rats. After incision, injury sensitivity of adult wide-dynamic-range neurons to both noxious and dynamic tactile hypersensitivity was significantly greater in NP animals compared with TC and undisturbed controls. We conclude that both repeated touch and needle-prick stimulation in the neonatal period can alter adult spinal sensory neuron sensitivity to both innocuous and noxious mechanical stimulation. Thus, spinal sensory circuits underlying touch and pain processing are shaped by a range of early-life somatosensory experiences.This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  8. Changes in spinal range of motion after a flexibility training program in elderly women

    Directory of Open Access Journals (Sweden)

    Battaglia G

    2014-04-01

    Full Text Available Giuseppe Battaglia,1,2 Marianna Bellafiore,1,2 Giovanni Caramazza,2 Antonio Paoli,3 Antonino Bianco,1,2 Antonio Palma1,2 1Department of Law, Society, and Sport Sciences, University of Palermo, Palermo, Italy; 2Sicilian Regional Sports School of Italian National Olympic Committee (CONI, Sicily, Italy; 3Department of Biomedical Sciences, University of Padova, Padova, Italy Background: Aging-related reduced spinal mobility can interfere with the execution of important functional skills and activities in elderly women. Although several studies have shown positive outcomes in response to spinal flexibility training programs, little is known about the management of sets and repetitions in training protocols. The purpose of this study was to investigate the effects of an 8-week specific and standardized flexibility training program on the range of spinal motion in elderly women. Methods: Participants were recruited in a senior center of Palermo and randomly assigned in two groups: trained group (TG and control group (CG, which included 19 and 18 women, respectively. TG was trained for 8 weeks at two sessions/week. In particular, every session included three phases: warm up (~10 minutes, central period (~50 minutes, and cool down (~10 minutes. CG did not perform any physical activity during the experimental period. Spinal ranges of motion (ROM were measured from neutral standing position to maximum bending position and from neutral standing position to maximum extension position before and after the experimental period, using a SpinalMouse® device (Idiag, Volkerswill, Switzerland. Results: After the training period, TG showed an increase in spinal inclination by 16.4% (P<0.05, in sacral/hip ROM by 29.2% (P<0.05, and in thoracic ROM by 22.5% (P>0.05 compared with CG from maximum extension position to maximum bending position. We did not observe any significant difference in TG's lumbar ROM compared with CG after the training period (P>0.05. Conclusion

  9. Neural network for adapting nuclear power plant control for wide-range operation

    International Nuclear Information System (INIS)

    Ku, C.C.; Lee, K.Y.; Edwards, R.M.

    1991-01-01

    A new concept of using neural networks has been evaluated for optimal control of a nuclear reactor. The neural network uses the architecture of a standard backpropagation network; however, a new dynamic learning algorithm has been developed to capture the underlying system dynamics. The learning algorithm is based on parameter estimation for dynamic systems. The approach is demonstrated on an optimal reactor temperature controller by adjusting the feedback gains for wide-range operation. Application of optimal control to a reactor has been considered for improving temperature response using a robust fifth-order reactor power controller. Conventional gain scheduling can be employed to extend the range of good performance to accommodate large changes in power where nonlinear characteristics significantly modify the dynamics of the power plant. Gain scheduling is developed based on expected parameter variations, and it may be advantageous to further adapt feedback gains on-line to better match actual plant performance. A neural network approach is used here to adapt the gains to better accommodate plant uncertainties and thereby achieve improved robustness characteristics

  10. Image dynamic range test and evaluation of Gaofen-2 dual cameras

    Science.gov (United States)

    Zhang, Zhenhua; Gan, Fuping; Wei, Dandan

    2015-12-01

    In order to fully understand the dynamic range of Gaofen-2 satellite data and support the data processing, application and next satellites development, in this article, we evaluated the dynamic range by calculating some statistics such as maximum ,minimum, average and stand deviation of four images obtained at the same time by Gaofen-2 dual cameras in Beijing area; then the maximum ,minimum, average and stand deviation of each longitudinal overlap of PMS1,PMS2 were calculated respectively for the evaluation of each camera's dynamic range consistency; and these four statistics of each latitudinal overlap of PMS1,PMS2 were calculated respectively for the evaluation of the dynamic range consistency between PMS1 and PMS2 at last. The results suggest that there is a wide dynamic range of DN value in the image obtained by PMS1 and PMS2 which contains rich information of ground objects; in general, the consistency of dynamic range between the single camera images is in close agreement, but also a little difference, so do the dual cameras. The consistency of dynamic range between the single camera images is better than the dual cameras'.

  11. ISSLS PRIZE IN BIOENGINEERING SCIENCE 2018: dynamic imaging of degenerative spondylolisthesis reveals mid-range dynamic lumbar instability not evident on static clinical radiographs.

    Science.gov (United States)

    Dombrowski, Malcolm E; Rynearson, Bryan; LeVasseur, Clarissa; Adgate, Zach; Donaldson, William F; Lee, Joon Y; Aiyangar, Ameet; Anderst, William J

    2018-04-01

    Degenerative spondylolisthesis (DS) in the setting of symptomatic lumbar spinal stenosis is commonly treated with spinal fusion in addition to decompression with laminectomy. However, recent studies have shown similar clinical outcomes after decompression alone, suggesting that a subset of DS patients may not require spinal fusion. Identification of dynamic instability could prove useful for predicting which patients are at higher risk of post-laminectomy destabilization necessitating fusion. The goal of this study was to determine if static clinical radiographs adequately characterize dynamic instability in patients with lumbar degenerative spondylolisthesis (DS) and to compare the rotational and translational kinematics in vivo during continuous dynamic flexion activity in DS versus asymptomatic age-matched controls. Seven patients with symptomatic single level lumbar DS (6 M, 1 F; 66 ± 5.0 years) and seven age-matched asymptomatic controls (5 M, 2 F age 63.9 ± 6.4 years) underwent biplane radiographic imaging during continuous torso flexion. A volumetric model-based tracking system was used to track each vertebra in the radiographic images using subject-specific 3D bone models from high-resolution computed tomography (CT). In vivo continuous dynamic sagittal rotation (flexion/extension) and AP translation (slip) were calculated and compared to clinical measures of intervertebral flexion/extension and AP translation obtained from standard lateral flexion/extension radiographs. Static clinical radiographs underestimate the degree of AP translation seen on dynamic in vivo imaging (1.0 vs 3.1 mm; p = 0.03). DS patients demonstrated three primary motion patterns compared to a single kinematic pattern in asymptomatic controls when analyzing continuous dynamic in vivo imaging. 3/7 (42%) of patients with DS demonstrated aberrant mid-range motion. Continuous in vivo dynamic imaging in DS reveals a spectrum of aberrant motion with significantly greater

  12. Overreaching in coordination dynamics therapy in an athlete with a spinal cord injury.

    Science.gov (United States)

    Schalow, G; Vaher, I; Jaigma, P

    2008-03-01

    A motocross athlete suffered a clinically complete spinal cord injury (SCI) during competition. Although MRIs (magnetic resonance imaging) showed a complete spinal cord injury at the Thoracic 11/12 levels, surface EMG recordings indicated the survival of few tract fibres across the injury site. Six weeks after the accident the subject began intensive Coordination Dynamics Therapy (CDT) at an up-to-date therapy centre. The subject trained at his physical limits to induce structural and functional repair. Exercising at variable loads between 20 and 200N (on a special CDT and recording device) generated periods of overreaching and super-compensation. By plotting coordination dynamics values (kinesiology), including high-load exertion (200N) and hysteresis curves, periods of overreaching and super-compensation were made graphically visible. It was found that symmetrical improvements of central nervous system (CNS) functioning occurred during overreaching. Improvements in spinal cord functioning were achieved throughout one year of CDT in this chronically injured subject with an almost anatomically complete SCI. It is discussed that the measuring of CNS functions by means of recording coordination dynamics is a powerful and non-invasive tool ideal for exact quantitative and qualitative measurements of improvement (or change) in CNS functioning. Such diagnostics may be of particular importance in sport during training and before competition. Also, coordination dynamics might be used to measure the effects of prolonged exposure to reduced gravitational conditions on CNS functions, such as faced by astronauts.

  13. Calibration device for wide range monitor

    International Nuclear Information System (INIS)

    Kodoku, Masaya; Sato, Toshifumi.

    1989-01-01

    The calibration device for a wide range monitor according to the present invention can continuously calibrate the entire counting regions of a wide range monitor. The wide range monitor detect the reactor power in the neutron source region by means of a pulse counting method and detects the reactor power in the intermediate region by means of a cambell method. A calibration signal outputting means is disposed for continuously outputting, as such calibration signals, pulse number varying signals in which the number of pulses per unit time varies depending on the reactor power in the neutron source region to be simulated and amplitude square means varying signal in which the mean square value of amplitude varies depending on the reactor power in the intermediate region to be simulated. By using both of the calibration signals, calibration can be conducted for the nuclear reactor power in the neutron source region and the intermediate region even if the calibration is made over two regions, further, calibration for the period present over the two region can be conducted easily as well. (I.S.)

  14. Brain abscess as a manifestation of spinal dermal sinus

    Directory of Open Access Journals (Sweden)

    Parisa Emami-Naeini

    2008-09-01

    Full Text Available Parisa Emami-Naeini, Ali Mahdavi, Hamed Ahmadi, Nima Baradaran, Farideh NejatDepartment of Neurosurgery, Children’s Hospital Medical Center, Medical Sciences/University of Tehran, Tehran, IranAbstract: Dermal sinuses have been associated with a wide spectrum of clinical manifestations ranging from asymptomatic to drainage of purulent material from the sinus tract, inclusion tumors, meningitis, and spinal abscess. To date, there has been no documented report of brain abscess as a complication of spinal dermal sinus. Here, we report an 8-month-old girl who was presented initially with a brain abscess at early infancy but lumbar dermal sinus and associated spinal abscess were discovered afterwards. The probable mechanisms of this rare association have been discussed.Keywords: brain abscess, spinal dermal sinus, spinal abscess

  15. Volumetric dynamic contrast enhanced Computed Tomography (DCE-CT) for preoperative assessment of the vascularity of spinal metastases

    DEFF Research Database (Denmark)

    Lauridsen, Carsten Ammitzbøl

    Purpose To investigate the feasibility of measuring and grading the vascularity of spinal metastases using dynamic contrast enhanced CT (DCE-CT). Materials and methods Prior to surgical treatment of symptomatic metastatic spinal cord compression, 20 patients were examined using DCE-CT. The 320......–detector row CT scanner allowed a volumetric acquisition over a range of 16 cm, covering three to four vertebrae. Image analysis was performed at a dedicated workstation, encompassing quantitative and qualitative measurement of the arterial flow (AF) in mL/min/100mL of the vertebrae. The perfusion values...... were analysed using a single input, maximum slope model. The AF assessed by DCE-CT of affected and non-affected vertebrae will be compared, and furthermore, the correlation between AF and intraoperative blood loss will be examined. Results Preliminary results for 5 patients: In two patients the AF...

  16. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique.

    Science.gov (United States)

    Khan, Md Rajibur Rahaman; Kang, Shin-Won

    2016-11-09

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal's pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R² is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry-Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.

  17. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique

    Science.gov (United States)

    Khan, Md. Rajibur Rahaman; Kang, Shin-Won

    2016-01-01

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal’s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R2 is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry–Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors. PMID:27834865

  18. 2.5 Gbit/s Optical Receiver Front-End Circuit with High Sensitivity and Wide Dynamic Range

    Science.gov (United States)

    Zhu, Tiezhu; Mo, Taishan; Ye, Tianchun

    2017-12-01

    An optical receiver front-end circuit is designed for passive optical network and fabricated in a 0.18 um CMOS technology. The whole circuit consists of a transimpedance amplifier (TIA), a single-ended to differential amplifier and an output driver. The TIA employs a cascode stage as the input stage and auxiliary amplifier to reduce the miller effect. Current injecting technique is employed to enlarge the input transistor's transconductance, optimize the noise performance and overcome the lack of voltage headroom. To achieve a wide dynamic range, an automatic gain control circuit with self-adaptive function is proposed. Experiment results show an optical sensitivity of -28 dBm for a bit error rate of 10-10 at 2.5 Gbit/s and a maxim input optical power of 2 dBm using an external photodiode. The chip occupies an area of 1×0.9 mm2 and consumes around 30 mW from single 1.8 V supply. The front-end circuit can be used in various optical receivers.

  19. Dynamic oscillatory signatures of central neuropathic pain in spinal cord injury.

    Science.gov (United States)

    Vuckovic, Aleksandra; Hasan, Muhammad A; Fraser, Matthew; Conway, Bernard A; Nasseroleslami, Bahman; Allan, David B

    2014-06-01

    Central neuropathic pain (CNP) is believed to be accompanied by increased activation of the sensorimotor cortex. Our knowledge of this interaction is based mainly on functional magnetic resonance imaging studies, but there is little direct evidence on how these changes manifest in terms of dynamic neuronal activity. This study reports on the presence of transient electroencephalography (EEG)-based measures of brain activity during motor imagery in spinal cord-injured patients with CNP. We analyzed dynamic EEG responses during imaginary movements of arms and legs in 3 groups of 10 volunteers each, comprising able-bodied people, paraplegic patients with CNP (lower abdomen and legs), and paraplegic patients without CNP. Paraplegic patients with CNP had increased event-related desynchronization in the theta, alpha, and beta bands (16-24 Hz) during imagination of movement of both nonpainful (arms) and painful limbs (legs). Compared to patients with CNP, paraplegics with no pain showed a much reduced power in relaxed state and reduced event-related desynchronization during imagination of movement. Understanding these complex dynamic, frequency-specific activations in CNP in the absence of nociceptive stimuli could inform the design of interventional therapies for patients with CNP and possibly further understanding of the mechanisms involved. This study compares the EEG activity of spinal cord-injured patients with CNP to that of spinal cord-injured patients with no pain and also to that of able-bodied people. The study shows that the presence of CNP itself leads to frequency-specific EEG signatures that could be used to monitor CNP and inform neuromodulatory treatments of this type of pain. Copyright © 2014 American Pain Society. Published by Elsevier Inc. All rights reserved.

  20. Differential diagnoses of spinal tumors; Differenzialdiagnose spinaler Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, U. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2011-12-15

    A wide variety of degenerative, inflammatory and vascular diseases can resemble the clinical presentation and imaging findings of spinal tumors. This article provides an overview of the most frequent diseases which are important to recognize for diagnostic imaging of the spine. (orig.) [German] Eine Vielzahl degenerativer, entzuendlicher und vaskulaerer Erkrankungen kann das klinische Bild und radiologische Befunde spinaler Tumoren imitieren. Dieser Artikel dient der Uebersicht ueber die haeufigsten dieser Erkrankungen, deren Kenntnis wichtig fuer die spinale Bildgebung ist. (orig.)

  1. High-dynamic-range imaging for cloud segmentation

    Science.gov (United States)

    Dev, Soumyabrata; Savoy, Florian M.; Lee, Yee Hui; Winkler, Stefan

    2018-04-01

    Sky-cloud images obtained from ground-based sky cameras are usually captured using a fisheye lens with a wide field of view. However, the sky exhibits a large dynamic range in terms of luminance, more than a conventional camera can capture. It is thus difficult to capture the details of an entire scene with a regular camera in a single shot. In most cases, the circumsolar region is overexposed, and the regions near the horizon are underexposed. This renders cloud segmentation for such images difficult. In this paper, we propose HDRCloudSeg - an effective method for cloud segmentation using high-dynamic-range (HDR) imaging based on multi-exposure fusion. We describe the HDR image generation process and release a new database to the community for benchmarking. Our proposed approach is the first using HDR radiance maps for cloud segmentation and achieves very good results.

  2. Inhibitory effects of aspirin-triggered resolvin D1 on spinal nociceptive processing in rat pain models.

    Science.gov (United States)

    Meesawatsom, Pongsatorn; Burston, James; Hathway, Gareth; Bennett, Andrew; Chapman, Victoria

    2016-09-02

    Harnessing the actions of the resolvin pathways has the potential for the treatment of a wide range of conditions associated with overt inflammatory signalling. Aspirin-triggered resolvin D1 (AT-RvD1) has robust analgesic effects in behavioural models of pain; however, the potential underlying spinal neurophysiological mechanisms contributing to these inhibitory effects in vivo are yet to be determined. This study investigated the acute effects of spinal AT-RvD1 on evoked responses of spinal neurones in vivo in a model of acute inflammatory pain and chronic osteoarthritic (OA) pain and the relevance of alterations in spinal gene expression to these neurophysiological effects. Pain behaviour was assessed in rats with established carrageenan-induced inflammatory or monosodium iodoacetate (MIA)-induced OA pain, and changes in spinal gene expression of resolvin receptors and relevant enzymatic pathways were examined. At timepoints of established pain behaviour, responses of deep dorsal horn wide dynamic range (WDR) neurones to transcutaneous electrical stimulation of the hind paw were recorded pre- and post direct spinal administration of AT-RvD1 (15 and 150 ng/50 μl). AT-RvD1 (15 ng/50 μl) significantly inhibited WDR neurone responses to electrical stimuli at C- (29 % inhibition) and Aδ-fibre (27 % inhibition) intensities. Both wind-up (53 %) and post-discharge (46 %) responses of WDR neurones in carrageenan-treated animals were significantly inhibited by AT-RvD1, compared to pre-drug response (p < 0.05). These effects were abolished by spinal pre-administration of a formyl peptide receptor 2 (FPR2/ALX) antagonist, butoxy carbonyl-Phe-Leu-Phe-Leu-Phe (BOC-2) (50 μg/50 μl). AT-RvD1 did not alter evoked WDR neurone responses in non-inflamed or MIA-treated rats. Electrophysiological effects in carrageenan-inflamed rats were accompanied by a significant increase in messenger RNA (mRNA) for chemerin (ChemR23) receptor and 5-lipoxygenase

  3. Gain control mechanisms in spinal motoneurons

    Directory of Open Access Journals (Sweden)

    Michael David Johnson

    2014-07-01

    Full Text Available Motoneurons provide the only conduit for motor commands to reach muscles. For many years, motoneurons were in fact considered to be little more than passive wires. Systematic studies in the past 25 years however have clearly demonstrated that the intrinsic electrical properties of motoneurons are under strong neuromodulatory control via multiple sources. The discovery of potent neuromodulation from the brainstem and its ability to change the gain of motoneurons shows that the passive view of the motor output stage is no longer tenable. A mechanism for gain control at the motor output stage makes good functional sense considering our capability of generating an enormous range of forces, from very delicate (e.g. putting in a contact lens to highly forceful (emergency reactions. Just as sensory systems need gain control to deal with a wide dynamic range of inputs, so to might motor output need gain control to deal with the wide dynamic range of the normal movement repertoire. Two problems emerge from the potential use of the brainstem monoaminergic projection to motoneurons for gain control. First, the projection is highly diffuse anatomically, so that independent control of the gains of different motor pools is not feasible. In fact, the system is so diffuse that gain for all the motor pools in a limb likely increases in concert. Second, if there is a system that increases gain, probably a system to reduce gain is also needed. In this review, we summarize recent studies that show local inhibitory circuits within the spinal cord, especially reciprocal and recurrent inhibition, have the potential to solve both of these problems as well as constitute another source of gain modulation.

  4. Mitochondrial uncouplers with an extraordinary dynamic range.

    Science.gov (United States)

    Lou, Phing-How; Hansen, Birgit S; Olsen, Preben H; Tullin, Søren; Murphy, Michael P; Brand, Martin D

    2007-10-01

    We have discovered that some weak uncouplers (typified by butylated hydroxytoluene) have a dynamic range of more than 10(6) in vitro: the concentration giving measurable uncoupling is less than one millionth of the concentration causing full uncoupling. They achieve this through a high-affinity interaction with the mitochondrial adenine nucleotide translocase that causes significant but limited uncoupling at extremely low uncoupler concentrations, together with more conventional uncoupling at much higher concentrations. Uncoupling at the translocase is not by a conventional weak acid/anion cycling mechanism since it is also caused by substituted triphenylphosphonium molecules, which are not anionic and cannot protonate. Covalent attachment of the uncoupler to a mitochondrially targeted hydrophobic cation sensitizes it to membrane potential, giving a small additional effect. The wide dynamic range of these uncouplers in isolated mitochondria and intact cells reveals a novel allosteric activation of proton transport through the adenine nucleotide translocase and provides a promising starting point for designing safer uncouplers for obesity therapy.

  5. Investigating Circadian Rhythmicity in Pain Sensitivity Using a Neural Circuit Model for Spinal Cord Processing of Pain

    DEFF Research Database (Denmark)

    Crodelle, Jennifer; Piltz, Sofia Helena; Booth, Victoria

    2017-01-01

    Primary processing of painful stimulation occurs in the dorsal horn of the spinal cord. In this article, we introduce mathematical models of the neural circuitry in the dorsal horn responsible for processing nerve fiber inputs from noxious stimulation of peripheral tissues and generating the resu......Primary processing of painful stimulation occurs in the dorsal horn of the spinal cord. In this article, we introduce mathematical models of the neural circuitry in the dorsal horn responsible for processing nerve fiber inputs from noxious stimulation of peripheral tissues and generating...... the resultant pain signal. The differential equation models describe the average firing rates of excitatory and inhibitory interneuron populations, as well as the wide dynamic range (WDR) neurons whose output correlates with the pain signal. The temporal profile of inputs on the different afferent nerve fibers...

  6. Design of a Dynamic Spinal Implant for the treatment of Early Onset Scoliosis

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Alvarez, A.; Shepherd, D.; Dearn, K.

    2016-07-01

    GSDyn (Growing Spine Dynamic) is a novel implant that has been designed and manufactured to mechanically correct three dimensional spinal deformities in children with Early Onset Scoliosis (EOS). The innovative element of the implant is the lengthening mechanism that allows the elongation surgeries to be easier, faster and less invasive procedures than with other mechanical implants on the market, as they can be performed under local anaesthetics and with a surgical incision of less than one centimetre. It also includes a dynamic system to prevent implant breakage and anchor loosening, two of the most common complications occurring in this treatment. The development of the implant has been guided by spinal surgeons. Finite Element Analysis has been performed to evaluate the behaviour of the device under different loading conditions and two working prototypes have been successfully manufactured. (Author)

  7. Evaluation of color encodings for high dynamic range pixels

    Science.gov (United States)

    Boitard, Ronan; Mantiuk, Rafal K.; Pouli, Tania

    2015-03-01

    Traditional Low Dynamic Range (LDR) color spaces encode a small fraction of the visible color gamut, which does not encompass the range of colors produced on upcoming High Dynamic Range (HDR) displays. Future imaging systems will require encoding much wider color gamut and luminance range. Such wide color gamut can be represented using floating point HDR pixel values but those are inefficient to encode. They also lack perceptual uniformity of the luminance and color distribution, which is provided (in approximation) by most LDR color spaces. Therefore, there is a need to devise an efficient, perceptually uniform and integer valued representation for high dynamic range pixel values. In this paper we evaluate several methods for encoding colour HDR pixel values, in particular for use in image and video compression. Unlike other studies we test both luminance and color difference encoding in a rigorous 4AFC threshold experiments to determine the minimum bit-depth required. Results show that the Perceptual Quantizer (PQ) encoding provides the best perceptual uniformity in the considered luminance range, however the gain in bit-depth is rather modest. More significant difference can be observed between color difference encoding schemes, from which YDuDv encoding seems to be the most efficient.

  8. A micro-controller based wide range survey meter

    International Nuclear Information System (INIS)

    Bhingare, R.R.; Bajaj, K.C.; Kannan, S.

    2004-01-01

    Wide range survey meters (1μSv/h -10 Sv/h) with the detector(s) mounted at the end of a two-to-four meter-long extendable tube are widely used for radiation protection survey of difficult to reach locations and high dose rate areas, The commercially available survey meters of this type use two GM counters to cover a wide range of dose rate measurement. A new micro-controller based wide range survey meter using two Si diode detectors has been developed. The use of solid state detectors in the survey meter has a number of advantages like low power consumption, lighter battery powered detector probe, elimination of high voltage for the operation of the detectors, etc. The design uses infrared communication between the probe and the readout unit through a light-weight collapsible extension tube for high reliability. The design details and features are discussed in detail. (author)

  9. Wide range neutron detection system

    International Nuclear Information System (INIS)

    Todt, W.H. Sr.

    1978-01-01

    A neutron detection system for reactor control is described which is operable over a wide range of neutron flux levels. The system includes a fission type ionization chamber neutron detector, means for gamma and alpha signal compensation, and means for operating the neutron detector in the pulse counting mode for low neutron flux levels, and in the direct current mode for high neutron flux levels

  10. Spontaneous Spinal Epidural Hematoma as a Potentially Important Stroke Mimic

    Directory of Open Access Journals (Sweden)

    Tetsu Akimoto

    2014-01-01

    Full Text Available Hemiparesis develops in response to a wide range of neurological disorders, such as stroke, neoplasms and several inflammatory processes. Occasionally, it may also occur due to a lesion located in the high cervical spinal cord. In this concise review, we describe the features of spontaneous spinal epidural hematoma, which should be included in the large list of stroke mimics. Various concerns regarding the diagnostic and therapeutic conundrums relating to the condition are also discussed.

  11. A Wide Spectral Range Reflectance and Luminescence Imaging System

    Directory of Open Access Journals (Sweden)

    Tapani Hirvonen

    2013-10-01

    Full Text Available In this study, we introduce a wide spectral range (200–2500 nm imaging system with a 250 μm minimum spatial resolution, which can be freely modified for a wide range of resolutions and measurement geometries. The system has been tested for reflectance and luminescence measurements, but can also be customized for transmittance measurements. This study includes the performance results of the developed system, as well as examples of spectral images. Discussion of the system relates it to existing systems and methods. The wide range spectral imaging system that has been developed is however highly customizable and has great potential in many practical applications.

  12. Stability diagrams for continuous wide-range control of two mutually delay-coupled semiconductor lasers

    International Nuclear Information System (INIS)

    Junges, Leandro; Gallas, Jason A C

    2015-01-01

    The dynamics of two mutually delay-coupled semiconductor lasers has been frequently studied experimentally, numerically, and analytically either for weak or strong detuning between the lasers. Here, we present a systematic numerical investigation spanning all detuning ranges. We report high-resolution stability diagrams for wide ranges of the main control parameters of the laser, as described by the Lang–Kobayashi model. In particular, we detail the parameter influence on dynamical performance and map the distribution of chaotic pulsations and self-generated periodic spiking with arbitrary periodicity. Special attention is given to the unfolding of regular pulse packages for both symmetric and non-symmetric configurations with respect to detuning. The influence of the delay –time on the self-organization of periodic and chaotic laser phases as a function of the coupling and detuning is also described in detail. (paper)

  13. Radiographic Incidence of Spinal Osteopathologies in Captive Rhesus Monkeys (Macaca mulatta)

    OpenAIRE

    Hernández-Godínez, Braulio; Ibáñez-Contreras, Alejandra; Perdigón-Castañeda, Gerardo; Galván-Montaño, Alfonso; de Oca, Guadalupe García-Montes; Zapata-Valdez, Carinthia; Tena-Betancourt, Eduardo

    2010-01-01

    Degenerative spinal disease is a leading cause of chronic disability both in humans and animals. Although widely seen as a normal occurrence of aging, degenerative spinal disease can be caused by various genetic, iatrogenic, inflammatory, and congenital factors. The objective of this study was to characterize the degenerative spine-related diseases and the age at onset in a random subpopulation of 20 captive rhesus monkeys (Macaca mulatta; male, 13; female, 7; age: range, 4 to 27 y; median, 1...

  14. Spinal injury in sport

    Energy Technology Data Exchange (ETDEWEB)

    Barile, Antonio [Department of Radiology, University of L' Aquila, S. Salvatore Hospital, Via Vetoio, Coppito, 67100 L' Aquila (Italy)]. E-mail: antonio.barile@cc.univaq.it; Limbucci, Nicola [Department of Radiology, University of L' Aquila, S. Salvatore Hospital, Via Vetoio, Coppito, 67100 L' Aquila (Italy); Splendiani, Alessandra [Department of Radiology, University of L' Aquila, S. Salvatore Hospital, Via Vetoio, Coppito, 67100 L' Aquila (Italy); Gallucci, Massimo [Department of Radiology, University of L' Aquila, S. Salvatore Hospital, Via Vetoio, Coppito, 67100 L' Aquila (Italy); Masciocchi, Carlo [Department of Radiology, University of L' Aquila, S. Salvatore Hospital, Via Vetoio, Coppito, 67100 L' Aquila (Italy)

    2007-04-15

    Spinal injuries are very common among professional or amateur athletes. Spinal sport lesions can be classified in overuse and acute injuries. Overuse injuries can be found after years of repetitive spinal load during sport activity; however specific overuse injuries can also be found in adolescents. Acute traumas are common in contact sports. Most of the acute injuries are minor and self-healing, but severe and catastrophic events are possible. The aim of this article is to review the wide spectrum of spinal injuries related to sport activity, with special regard to imaging finding.

  15. Spinal injury in sport

    International Nuclear Information System (INIS)

    Barile, Antonio; Limbucci, Nicola; Splendiani, Alessandra; Gallucci, Massimo; Masciocchi, Carlo

    2007-01-01

    Spinal injuries are very common among professional or amateur athletes. Spinal sport lesions can be classified in overuse and acute injuries. Overuse injuries can be found after years of repetitive spinal load during sport activity; however specific overuse injuries can also be found in adolescents. Acute traumas are common in contact sports. Most of the acute injuries are minor and self-healing, but severe and catastrophic events are possible. The aim of this article is to review the wide spectrum of spinal injuries related to sport activity, with special regard to imaging finding

  16. MR imaging of spinal factors and compression of the spinal cord in cervical myelopathy

    International Nuclear Information System (INIS)

    Kokubun, Shoichi; Ozawa, Hiroshi; Sakurai, Minoru; Ishii, Sukenobu; Tani, Shotaro; Sato, Tetsuaki.

    1992-01-01

    Magnetic resonance (MR) images of surgical 109 patients with cervical spondylotic myelopathy were retrospectively reviewed to examine whether MR imaging would replace conventional radiological procedures in determining spinal factors and spinal cord compression in this disease. MR imaging was useful in determining spondylotic herniation, continuous type of ossification of posterior longitudinal ligament, and calcification of yellow ligament, probably replacing CT myelography, discography, and CT discography. When total defect of the subarachnoid space on T2-weighted images and block on myelograms were compared in determining spinal cord compression, the spinal cord was affected more extensively by 1.3 intervertebral distance (IVD) on T2-weighted images. When indentation of one third or more in anterior and posterior diameter of the spinal cord was used as spinal cord compression, the difference in the affected extension between myelography and MR imaging was 0.2 IVD on T1-weighted images and 0.6 IVD on T2-weighted images. However, when block was seen in 3 or more IVD on myelograms, the range of spinal cord compression tended to be larger on T1-weighted images. For a small range of spinal cord compression, T1-weighted imaging seems to be helpful in determining the range of decompression. When using T2-weighted imaging, the range of decompression becomes large, frequently including posterior decompression. (N.K.)

  17. Wide-Range Highly-Efficient Wireless Power Receivers for Implantable Biomedical Sensors

    KAUST Repository

    Ouda, Mahmoud

    2016-11-01

    Wireless power transfer (WPT) is the key enabler for a myriad of applications, from low-power RFIDs, and wireless sensors, to wirelessly charged electric vehicles, and even massive power transmission from space solar cells. One of the major challenges in designing implantable biomedical devices is the size and lifetime of the battery. Thus, replacing the battery with a miniaturized wireless power receiver (WPRx) facilitates designing sustainable biomedical implants in smaller volumes for sentient medical applications. In the first part of this dissertation, we propose a miniaturized, fully integrated, wirelessly powered implantable sensor with on-chip antenna, designed and implemented in a standard 0.18μm CMOS process. As a batteryless device, it can be implanted once inside the body with no need for further invasive surgeries to replace batteries. The proposed single-chip solution is designed for intraocular pressure monitoring (IOPM), and can serve as a sustainable platform for implantable devices or IoT nodes. A custom setup is developed to test the chip in a saline solution with electrical properties similar to those of the aqueous humor of the eye. The proposed chip, in this eye-like setup, is wirelessly charged to 1V from a 5W transmitter 3cm away from the chip. In the second part, we propose a self-biased, differential rectifier with enhanced efficiency over an extended range of input power. A prototype is designed for the medical implant communication service (MICS) band at 433MHz. It demonstrates an efficiency improvement of more than 40% in the rectifier power conversion efficiency (PCE) and a dynamic range extension of more than 50% relative to the conventional cross-coupled rectifier. A sensitivity of -15.2dBm input power for 1V output voltage and a peak PCE of 65% are achieved for a 50k load. In the third part, we propose a wide-range, differential RF-to-DC power converter using an adaptive, self-biasing technique. The proposed architecture doubles

  18. Spinal Trauma is Never without Sin: A Tetraplegia Patient Presented Without any Symptoms

    OpenAIRE

    EFEOGLU, Melis; AKOGLU, Haldun; AKOGLU, Tayfun; EROGLU, Serkan Emre; ONUR, Ozge Ecmel; DENIZBASI, Arzu

    2016-01-01

    SUMMARY: Spinal cord injuries are amongst the most dangerous injuries, leading to high mortality and morbidity. Injured patients are occasionally faced with life-threatening complications and quality-of-life changing neurological deficits. Thoracic and cervical spinal segments are the most effected sites of injury and a wide range of complications including paraplegia, respiratory and cardiovascular compromise secondary to autonomic dysfunction or tetraplegia may ensue. We aim to draw attenti...

  19. Wide-range voltage modulation

    International Nuclear Information System (INIS)

    Rust, K.R.; Wilson, J.M.

    1992-06-01

    The Superconducting Super Collider's Medium Energy Booster Abort (MEBA) kicker modulator will supply a current pulse to the abort magnets which deflect the proton beam from the MEB ring into a designated beam stop. The abort kicker will be used extensively during testing of the Low Energy Booster (LEB) and the MEB rings. When the Collider is in full operation, the MEBA kicker modulator will abort the MEB beam in the event of a malfunction during the filling process. The modulator must generate a 14-μs wide pulse with a rise time of less than 1 μs, including the delay and jitter times. It must also be able to deliver a current pulse to the magnet proportional to the beam energy at any time during ramp-up of the accelerator. Tracking the beam energy, which increases from 12 GeV at injection to 200 GeV at extraction, requires the modulator to operate over a wide range of voltages (4 kV to 80 kV). A vacuum spark gap and a thyratron have been chosen for test and evaluation as candidate switches for the abort modulator. Modulator design, switching time delay, jitter and pre-fire data are presented

  20. Organization of hyperactive microglial cells in trigeminal spinal subnucleus caudalis and upper cervical spinal cord associated with orofacial neuropathic pain.

    Science.gov (United States)

    Shibuta, Kazuo; Suzuki, Ikuko; Shinoda, Masamichi; Tsuboi, Yoshiyuki; Honda, Kuniya; Shimizu, Noriyoshi; Sessle, Barry J; Iwata, Koichi

    2012-04-27

    The aim of this study was to evaluate spatial organization of hyperactive microglial cells in trigeminal spinal subnucleus caudalis (Vc) and upper cervical spinal cord (C1), and to clarify the involvement in mechanisms underlying orofacial secondary hyperalgesia following infraorbital nerve injury. We found that the head-withdrawal threshold to non-noxious mechanical stimulation of the maxillary whisker pad skin was significantly reduced in chronic constriction injury of the infraorbital nerve (ION-CCI) rats from day 1 to day 14 after ION-CCI. On day 3 after ION-CCI, mechanical allodynia was obvious in the orofacial skin areas innervated by the 1st and 3rd branches of the trigeminal nerve as well as the 2nd branch area. Hyperactive microglial cells in Vc and C1 were observed on days 3 and 7 after ION-CCI. On day 3 after ION-CCI, a large number of phosphorylated extracellular signal-regulated kinase (pERK)-immunoreactive (IR) cells were observed in Vc and C1. Many hyperactive microglial cells were also distributed over a wide area of Vc and C1 innervated by the trigeminal nerve. The intraperitoneal administration of minocycline significantly reduced the activation of microglial cells and the number of pERK-IR cells in Vc and C1, and also significantly attenuated the development of mechanical allodynia. Furthermore, enhanced background activity and mechanical evoked responses of Vc wide dynamic range neurons in ION-CCI rats were significantly reversed following minocycline administration. These findings suggest that activation of microglial cells over a wide area of Vc and C1 is involved in the enhancement of Vc and C1 neuronal excitability in the early period after ION-CCI, resulting in the neuropathic pain in orofacial areas innervated by the injured as well as uninjured nerves. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. A wide temperature range irradiation cryostat for reasearch on solid state targets

    Energy Technology Data Exchange (ETDEWEB)

    Reeve, Scott; Dutz, Hartmut; Goertz, Stefan; Runkel, Stefan; Voge, Thomas [Physikalisches Institut, Universitaet Bonn (Germany)

    2012-07-01

    To qualitatively improve the data obtained in asymmetry measurements of scattering experiments the figure of merit (FOM) plays a major role and can reduce the data acquisition time when a certain precision in the measurement is needed. One of the defining factors for the improvement of the polarised experiment lies in the target choice and preparation, in particular the method employed to introduce the paramagnetic defects for the use of dynamic nuclear polarisation (DNP). To this end the Polarized Target Group in Bonn has developed a wide range temperature cryostat for the irradiation of potential target materials in which materials can be irradiated to varying doses at specified temperatures. The stable irradiation temperature of the materials can be controlled to within {+-}1 K over a range of 90 K

  2. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  3. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  4. Dynamic changes in the dural space and spinal cord cross-sectional area during flexion and extension in patients with cervical spondylotic myelopathy

    International Nuclear Information System (INIS)

    Machino, Masaaki; Yukawa, Yasutsugu; Ito, Keigo; Nakashima, Hiroaki; Kato, Fumihiko

    2009-01-01

    The number of patients with cervical spondylotic myelopathy (CSM) is increasing with the aging of the population. The patients' during spinal cord tends to be compressed neck extension, because the yellow ligaments and intervertebral discs protrude into the spinal canal during neck extension (pincer mechanism). A total of 100 patients with CSM were prospectively enrolled in this study. After preoperative myelography, multi-detector-row CT (MDCT) scans were acquired in flexion and extension, and the dural space and spinal cord cross-sectional area at each disc level from C2/3 to C7/Th1 were measured by using Scion imaging software. The average dural space and average spinal cord cross-sectional area were smaller in extension than in flexion from the C3/4 to C7/Th1 disc level, and the greatest dynamic changes were seen at the C5/6 level. MDCT demonstrated dynamic factors in patients with CSM. The spinal cord cross-sectional area became narrower during extension in patients with CSM. (author)

  5. Effect of ship motion on spinal loading during manual lifting

    NARCIS (Netherlands)

    Faber, G.S.; Kingma, I.; Delleman, N.; Dieën, J. van

    2008-01-01

    This study investigated the effects of ship motion on peak spinal loading during lifting. All measurements were done on a ship at sea. In 1-min trials, which were repeated over a wide range of sailing conditions, subjects lifted an 18 kg box five times. Ship motion, whole body kinematics, ground

  6. Electrophysiological characterization of activation state-dependent Ca(v)2 channel antagonist TROX-1 in spinal nerve injured rats.

    Science.gov (United States)

    Patel, R; Rutten, K; Valdor, M; Schiene, K; Wigge, S; Schunk, S; Damann, N; Christoph, T; Dickenson, A H

    2015-06-25

    Prialt, a synthetic version of Ca(v)2.2 antagonist ω-conotoxin MVIIA derived from Conus magus, is the first clinically approved voltage-gated calcium channel blocker for refractory chronic pain. However, due to the narrow therapeutic window and considerable side effects associated with systemic dosing, Prialt is only administered intrathecally. N-triazole oxindole (TROX-1) is a novel use-dependent and activation state-selective small-molecule inhibitor of Ca(v)2.1, 2.2 and 2.3 calcium channels designed to overcome the limitations of Prialt. We have examined the neurophysiological and behavioral effects of blocking calcium channels with TROX-1. In vitro, TROX-1, in contrast to state-independent antagonist Prialt, preferentially inhibits Ca(v)2.2 currents in rat dorsal root ganglia (DRG) neurons under depolarized conditions. In vivo electrophysiology was performed to record from deep dorsal horn lamina V/VI wide dynamic range neurons in non-sentient spinal nerve-ligated (SNL) and sham-operated rats. In SNL rats, spinal neurons exhibited reduced responses to innocuous and noxious punctate mechanical stimulation of the receptive field following subcutaneous administration of TROX-1, an effect that was absent in sham-operated animals. No effect was observed on neuronal responses evoked by dynamic brushing, heat or cold stimulation in SNL or sham rats. The wind-up response of spinal neurons following repeated electrical stimulation of the receptive field was also unaffected. Spinally applied TROX-1 dose dependently inhibited mechanically evoked neuronal responses in SNL but not sham-operated rats, consistent with behavioral observations. This study confirms the pathological state-dependent actions of TROX-1 through a likely spinal mechanism and reveals a modality selective change in calcium channel function following nerve injury. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Spinal motor control system incorporates an internal model of limb dynamics.

    Science.gov (United States)

    Shimansky, Y P

    2000-10-01

    The existence and utilization of an internal representation of the controlled object is one of the most important features of the functioning of neural motor control systems. This study demonstrates that this property already exists at the level of the spinal motor control system (SMCS), which is capable of generating motor patterns for reflex rhythmic movements, such as locomotion and scratching, without the aid of the peripheral afferent feedback, but substantially modifies the generated activity in response to peripheral afferent stimuli. The SMCS is presented as an optimal control system whose optimality requires that it incorporate an internal model (IM) of the controlled object's dynamics. A novel functional mechanism for the integration of peripheral sensory signals with the corresponding predictive output from the IM, the summation of information precision (SIP) is proposed. In contrast to other models in which the correction of the internal representation of the controlled object's state is based on the calculation of a mismatch between the internal and external information sources, the SIP mechanism merges the information from these sources in order to optimize the precision of the controlled object's state estimate. It is demonstrated, based on scratching in decerebrate cats as an example of the spinal control of goal-directed movements, that the results of computer modeling agree with the experimental observations related to the SMCS's reactions to phasic and tonic peripheral afferent stimuli. It is also shown that the functional requirements imposed by the mathematical model of the SMCS comply with the current knowledge about the related properties of spinal neuronal circuitry. The crucial role of the spinal presynaptic inhibition mechanism in the neuronal implementation of SIP is elucidated. Important differences between the IM and a state predictor employed for compensating for a neural reflex time delay are discussed.

  8. Suppressive Effects of Bee Venom Acupuncture on Paclitaxel-Induced Neuropathic Pain in Rats: Mediation by Spinal α2-Adrenergic Receptor

    Directory of Open Access Journals (Sweden)

    Jiho Choi

    2017-10-01

    Full Text Available Paclitaxel, a chemotherapy drug for solid tumors, induces peripheral painful neuropathy. Bee venom acupuncture (BVA has been reported to have potent analgesic effects, which are known to be mediated by activation of spinal α-adrenergic receptor. Here, we investigated the effect of BVA on mechanical hyperalgesia and spinal neuronal hyperexcitation induced by paclitaxel. The role of spinal α-adrenergic receptor subtypes in the analgesic effect of BVA was also observed. Administration of paclitaxel (total 8 mg/kg, intraperitoneal on four alternate days (days 0, 2, 4, and 6 induced significant mechanical hyperalgesic signs, measured using a von Frey filament. BVA (1 mg/kg, ST36 relieved this mechanical hyperalgesia for at least two hours, and suppressed the hyperexcitation in spinal wide dynamic range neurons evoked by press or pinch stimulation. Both melittin (0.5 mg/kg, ST36 and phospholipase A2 (0.12 mg/kg, ST36 were shown to play an important part in this analgesic effect of the BVA, as they significantly attenuated the pain. Intrathecal pretreatment with the α2-adrenergic receptor antagonist (idazoxan, 50 µg, but not α1-adrenergic receptor antagonist (prazosin, 30 µg, blocked the analgesic effect of BVA. These results suggest that BVA has potent suppressive effects against paclitaxel-induced neuropathic pain, which were mediated by spinal α2-adrenergic receptor.

  9. Suppressive Effects of Bee Venom Acupuncture on Paclitaxel-Induced Neuropathic Pain in Rats: Mediation by Spinal α₂-Adrenergic Receptor.

    Science.gov (United States)

    Choi, Jiho; Jeon, Changhoon; Lee, Ji Hwan; Jang, Jo Ung; Quan, Fu Shi; Lee, Kyungjin; Kim, Woojin; Kim, Sun Kwang

    2017-10-31

    Paclitaxel, a chemotherapy drug for solid tumors, induces peripheral painful neuropathy. Bee venom acupuncture (BVA) has been reported to have potent analgesic effects, which are known to be mediated by activation of spinal α-adrenergic receptor. Here, we investigated the effect of BVA on mechanical hyperalgesia and spinal neuronal hyperexcitation induced by paclitaxel. The role of spinal α-adrenergic receptor subtypes in the analgesic effect of BVA was also observed. Administration of paclitaxel (total 8 mg/kg, intraperitoneal) on four alternate days (days 0, 2, 4, and 6) induced significant mechanical hyperalgesic signs, measured using a von Frey filament. BVA (1 mg/kg, ST36) relieved this mechanical hyperalgesia for at least two hours, and suppressed the hyperexcitation in spinal wide dynamic range neurons evoked by press or pinch stimulation. Both melittin (0.5 mg/kg, ST36) and phospholipase A2 (0.12 mg/kg, ST36) were shown to play an important part in this analgesic effect of the BVA, as they significantly attenuated the pain. Intrathecal pretreatment with the α₂-adrenergic receptor antagonist (idazoxan, 50 µg), but not α₁-adrenergic receptor antagonist (prazosin, 30 µg), blocked the analgesic effect of BVA. These results suggest that BVA has potent suppressive effects against paclitaxel-induced neuropathic pain, which were mediated by spinal α₂-adrenergic receptor.

  10. Non-uniform sampling and wide range angular spectrum method

    International Nuclear Information System (INIS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Lee, JaeWon; Pi, Jae-Eun; Heon Kim, Gi; Lee, Myung-Lae; Ryu, Hojun; Chu, Hye-Yong; Hwang, Chi-Sun

    2014-01-01

    A novel method is proposed for simulating free space field propagation from a source plane to a destination plane that is applicable for both small and large propagation distances. The angular spectrum method (ASM) was widely used for simulating near field propagation, but it caused a numerical error when the propagation distance was large because of aliasing due to under sampling. Band limited ASM satisfied the Nyquist condition on sampling by limiting a bandwidth of a propagation field to avoid an aliasing error so that it could extend the applicable propagation distance of the ASM. However, the band limited ASM also made an error due to the decrease of an effective sampling number in a Fourier space when the propagation distance was large. In the proposed wide range ASM, we use a non-uniform sampling in a Fourier space to keep a constant effective sampling number even though the propagation distance is large. As a result, the wide range ASM can produce simulation results with high accuracy for both far and near field propagation. For non-paraxial wave propagation, we applied the wide range ASM to a shifted destination plane as well. (paper)

  11. Directly measuring spinal cord blood flow and spinal cord perfusion pressure via the collateral network: correlations with changes in systemic blood pressure.

    Science.gov (United States)

    Kise, Yuya; Kuniyoshi, Yukio; Inafuku, Hitoshi; Nagano, Takaaki; Hirayasu, Tsuneo; Yamashiro, Satoshi

    2015-01-01

    During thoracoabdominal surgery in which segmental arteries are sacrificed over a large area, blood supply routes from collateral networks have received attention as a means of avoiding spinal cord injury. The aim of this study was to investigate spinal cord blood supply through a collateral network by directly measuring spinal cord blood flow and spinal cord perfusion pressure experimentally. In beagle dogs (n = 8), the thoracoabdominal aorta and segmental arteries L1-L7 were exposed, and a temporary bypass was created for distal perfusion. Next, a laser blood flow meter was placed on the spinal dura mater in the L5 region to measure the spinal cord blood flow. The following were measured simultaneously when the direct blood supply from segmental arteries L2-L7 to the spinal cord was stopped: mean systemic blood pressure, spinal cord perfusion pressure (blood pressure within the aortic clamp site), and spinal cord blood flow supplied via the collateral network. These variables were then investigated for evidence of correlations. Positive correlations were observed between mean systemic blood pressure and spinal cord blood flow during interruption of segmental artery flow both with (r = 0.844, P flow with and without distal perfusion (r = 0.803, P network from outside the interrupted segmental arteries, and high systemic blood pressure (∼1.33-fold higher) was needed to obtain the preclamping spinal cord blood flow, whereas 1.68-fold higher systemic blood pressure was needed when distal perfusion was halted. Spinal cord blood flow is positively correlated with mean systemic blood pressure and spinal cord perfusion pressure under spinal cord ischemia caused by clamping a wide range of segmental arteries. In open and endovascular thoracic and thoracoabdominal surgery, elevating mean systemic blood pressure is a simple and effective means of increasing spinal cord blood flow, and measuring spinal cord perfusion pressure seems to be useful for monitoring

  12. Modelling of monovacancy diffusion in W over wide temperature range

    International Nuclear Information System (INIS)

    Bukonte, L.; Ahlgren, T.; Heinola, K.

    2014-01-01

    The diffusion of monovacancies in tungsten is studied computationally over a wide temperature range from 1300 K until the melting point of the material. Our modelling is based on Molecular Dynamics technique and Density Functional Theory. The monovacancy migration barriers are calculated using nudged elastic band method for nearest and next-nearest neighbour monovacancy jumps. The diffusion pre-exponential factor for monovacancy diffusion is found to be two to three orders of magnitude higher than commonly used in computational studies, resulting in attempt frequency of the order 10 15 Hz. Multiple nearest neighbour jumps of monovacancy are found to play an important role in the contribution to the total diffusion coefficient, especially at temperatures above 2/3 of T m , resulting in an upward curvature of the Arrhenius diagram. The probabilities for different nearest neighbour jumps for monovacancy in W are calculated at different temperatures

  13. Technique for increasing dynamic range of space-borne ion composition instruments

    International Nuclear Information System (INIS)

    Burch, J.L.; Miller, G.P.; Santos, A. de los; Pollock, C.J.; Pope, S.E.; Valek, P. W.; Young, D.T.

    2005-01-01

    The dynamic range of ion composition spectrometers is limited by several factors, including saturation of particle counters and spillover of signals from highly dominant species into channels tuned to minor species. Instruments designed for composition measurements of hot plasmas in space can suffer greatly from both of these problems because of the wide energy range required and the wide disparity in fluxes encountered in various regions of interest. In order to detect minor ions in regions of very weak fluxes, geometry factors need to be as large as possible within the mass and volume resources available. As a result, problems with saturation by the dominant fluxes and spillover to minor-ion channels in plasma regions with intense fluxes become especially acute. This article reports on a technique for solving the dynamic-range problem in the few eV to several keV energy/charge range that is of central importance for space physics research where the dominant ion is of low mass/charge (typically H + ), and the minor ions are of higher mass/charge (typically O + ). The technique involves employing a radio-frequency modulation of the deflection electric field in the back section of an electrostatic analyzer in a time-of-flight instrument. This technique is shown to reduce H + counts by a controllable amount of up to factors of 1000 while reducing O + counts by only a few percent that can be calibrated

  14. The MOLDY short-range molecular dynamics package

    Science.gov (United States)

    Ackland, G. J.; D'Mellow, K.; Daraszewicz, S. L.; Hepburn, D. J.; Uhrin, M.; Stratford, K.

    2011-12-01

    We describe a parallelised version of the MOLDY molecular dynamics program. This Fortran code is aimed at systems which may be described by short-range potentials and specifically those which may be addressed with the embedded atom method. This includes a wide range of transition metals and alloys. MOLDY provides a range of options in terms of the molecular dynamics ensemble used and the boundary conditions which may be applied. A number of standard potentials are provided, and the modular structure of the code allows new potentials to be added easily. The code is parallelised using OpenMP and can therefore be run on shared memory systems, including modern multicore processors. Particular attention is paid to the updates required in the main force loop, where synchronisation is often required in OpenMP implementations of molecular dynamics. We examine the performance of the parallel code in detail and give some examples of applications to realistic problems, including the dynamic compression of copper and carbon migration in an iron-carbon alloy. Program summaryProgram title: MOLDY Catalogue identifier: AEJU_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEJU_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public License version 2 No. of lines in distributed program, including test data, etc.: 382 881 No. of bytes in distributed program, including test data, etc.: 6 705 242 Distribution format: tar.gz Programming language: Fortran 95/OpenMP Computer: Any Operating system: Any Has the code been vectorised or parallelized?: Yes. OpenMP is required for parallel execution RAM: 100 MB or more Classification: 7.7 Nature of problem: Moldy addresses the problem of many atoms (of order 10 6) interacting via a classical interatomic potential on a timescale of microseconds. It is designed for problems where statistics must be gathered over a number of equivalent runs, such as

  15. The dynamic evaluation of the cervical spinal canal and spinal cord by magnetic resonance imaging during movement

    International Nuclear Information System (INIS)

    Koschorek, F.; Jensen, H.P.; Terwey, B.

    1987-01-01

    The authors present results of in vivo measurements of the cervical canal and spinal cord. They indicate that tension in the spinal cord increases during flexion. They conclude that, as the dorsal approach avoids this increased tension of the spinal cord, the surgical treatment in chronic cervical myelopathy using this route seems to be preferable

  16. High Precision Stokes Polarimetry for Scattering Light using Wide Dynamic Range Intensity Detector

    Directory of Open Access Journals (Sweden)

    Shibata Shuhei

    2015-01-01

    Full Text Available This paper proposes a Stokes polarimetry for scattering light from a sample surface. To achieve a high accuracy measurement two approaches of an intensity detector and analysis algorism of a Stokes parameter were proposed. The dynamic range of this detector can achieve up to 1010 by combination of change of neutral-density (ND filters having different density and photon counting units. Stokes parameters can be measured by dual rotating of a retarder and an analyzer. The algorism of dual rotating polarimeter can be calibrated small linear diattenuation and linear retardance error of the retarder. This system can measured Stokes parameters from −20° to 70° of its scattering angle. It is possible to measure Stokes parameters of scattering of dust and scratch of optical device with high precision. This paper shows accuracy of this system, checking the polarization change of scattering angle and influence of beam size.

  17. Soil Compressibility Models for a Wide Stress Range

    KAUST Repository

    Chong, Song-Hun; Santamarina, Carlos

    2016-01-01

    Soil compressibility models with physically correct asymptotic void ratios are required to analyze situations that involve a wide stress range. Previously suggested models and other functions are adapted to satisfy asymptotic void ratios at low

  18. Picosecond X-ray streak camera dynamic range measurement

    Energy Technology Data Exchange (ETDEWEB)

    Zuber, C., E-mail: celine.zuber@cea.fr; Bazzoli, S.; Brunel, P.; Gontier, D.; Raimbourg, J.; Rubbelynck, C.; Trosseille, C. [CEA, DAM, DIF, F-91297 Arpajon (France); Fronty, J.-P.; Goulmy, C. [Photonis SAS, Avenue Roger Roncier, BP 520, 19106 Brive Cedex (France)

    2016-09-15

    Streak cameras are widely used to record the spatio-temporal evolution of laser-induced plasma. A prototype of picosecond X-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to answer the Laser MegaJoule specific needs. The dynamic range of this instrument is measured with picosecond X-ray pulses generated by the interaction of a laser beam and a copper target. The required value of 100 is reached only in the configurations combining the slowest sweeping speed and optimization of the streak tube electron throughput by an appropriate choice of high voltages applied to its electrodes.

  19. Spinal fusion limits upper body range of motion during gait without inducing compensatory mechanisms in adolescent idiopathic scoliosis patients.

    Science.gov (United States)

    Holewijn, R M; Kingma, I; de Kleuver, M; Schimmel, J J P; Keijsers, N L W

    2017-09-01

    Previous studies show a limited alteration of gait at normal walking speed after spinal fusion surgery for adolescent idiopathic scoliosis (AIS), despite the presumed essential role of spinal mobility during gait. This study analyses how spinal fusion affects gait at more challenging walking speeds. More specifically, we investigated whether thoracic-pelvic rotations are reduced to a larger extent at higher gait speeds and whether compensatory mechanisms above and below the stiffened spine are present. 18 AIS patients underwent gait analysis at increasing walking speeds (0.45 to 2.22m/s) before and after spinal fusion. The range of motion (ROM) of the upper (thorax, thoracic-pelvic and pelvis) and lower body (hip, knee and ankle) was determined in all three planes. Spatiotemporal parameters of interest were stride length and cadence. Spinal fusion diminished transverse plane thoracic-pelvic ROM and this difference was more explicit at higher walking speeds. Transversal pelvis ROM was also decreased but this effect was not affected by speed. Lower body ROM, step length and cadence remained unaffected. Despite the reduction of upper body ROM after spine surgery during high speed gait, no altered spatiotemporal parameters or increased compensatory ROM above or below the fusion (i.e. in the shoulder girdle or lower extremities) was identified. Thus, it remains unclear how patients can cope so well with such major surgery. Future studies should focus on analyzing the kinematics of individual spinal levels above and below the fusion during gait to investigate possible compensatory mechanisms within the spine. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Use of a dynamic gait trainer for a child with thoracic level spinal cord injury.

    Science.gov (United States)

    Altizer, Wendy; Noritz, Garey; Paleg, Ginny

    2017-10-10

    Paediatric spinal cord injury (SCI) can result in permanent mobility impairment with consequences for activity, participation and quality of life. This case documents the effect of an overground supported stepping intervention using a dynamic gait trainer. To our knowledge, there are no published studies on this intervention for children with SCI and similar interventions have only been reported in children at American Spinal Injury Association Impairment Scale (AIS) levels B and C.A child with a T10 (thoracic level, vertebra 10), AIS level A injury, sustained at 2 years of age, continued to make gains in all areas including participation, activity, body structure and function over the following 4 years. Use of a dynamic gait trainer improved the participant's ability to be active and participate despite lack of further neuromuscular recovery. This novel approach with a commonly available device allowed the child to be active and participate in the absence of neural recovery. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. High voltage wide range marx generator design and construction

    International Nuclear Information System (INIS)

    Thompson, J.E.

    1976-01-01

    A wide range, long pulse, Marx generator has been designed and constructed for the purpose of exciting a thermionic electron gun utilized for quasi-cw gas laser medium ionization. The Marx generator has been specifically designed to operate over a voltage range variable from 100 kV to 200 kV into a resistive load of between 83 kΩ and open circuit. This wide operating range, both in voltage and load impedance, was obtained using interstage coupling capacitors to assure overvoltage and subsequent breakdown of the three element spark gap switches used. This paper will discuss the motivation and specific application for the Marx generator and will present the relevant design procedure with particular emphasis on the interstage coupling and triggering techniques employed. Experimental data regarding the measured Marx generator performance will also be presented

  2. Anatomy of the Spinal Meninges.

    Science.gov (United States)

    Sakka, Laurent; Gabrillargues, Jean; Coll, Guillaume

    2016-06-01

    The spinal meninges have received less attention than the cranial meninges in the literature, although several points remain debatable and poorly understood, like their phylogenesis, their development, and their interactions with the spinal cord. Their constancy among the chordates shows their crucial importance in central nervous system homeostasis and suggests a role far beyond mechanical protection of the neuraxis. This work provides an extensive study of the spinal meninges, from an overview of their phylogenesis and embryology to a descriptive and topographic anatomy with clinical implications. It examines their involvement in spinal cord development, functioning, and repair. This work is a review of the literature using PubMed as a search engine on Medline. The stages followed by the meninges along the phylogenesis could not be easily compared with their development in vertebrates for methodological aspects and convergence processes throughout evolution. The distinction between arachnoid and pia mater appeared controversial. Several points of descriptive anatomy remain debatable: the functional organization of the arterial network, and the venous and lymphatic drainages, considered differently by classical anatomic and neuroradiological approaches. Spinal meninges are involved in neurodevelopment and neurorepair producing neural stem cells and morphogens, in cerebrospinal fluid dynamics and neuraxis functioning by the synthesis of active molecules, and the elimination of waste products of central nervous system metabolism. The spinal meninges should be considered as dynamic functional formations evolving over a lifetime, with ultrastructural features and functional interactions with the neuraxis remaining not fully understood.

  3. Seasonality in cholera dynamics: A rainfall-driven model explains the wide range of patterns in endemic areas

    Science.gov (United States)

    Baracchini, Theo; King, Aaron A.; Bouma, Menno J.; Rodó, Xavier; Bertuzzo, Enrico; Pascual, Mercedes

    2017-10-01

    Seasonal patterns in cholera dynamics exhibit pronounced variability across geographical regions, showing single or multiple peaks at different times of the year. Although multiple hypotheses related to local climate variables have been proposed, an understanding of this seasonal variation remains incomplete. The historical Bengal region, which encompasses the full range of cholera's seasonality observed worldwide, provides a unique opportunity to gain insights on underlying environmental drivers. Here, we propose a mechanistic, rainfall-temperature driven, stochastic epidemiological model which explicitly accounts for the fluctuations of the aquatic reservoir, and analyze with this model the historical dataset of cholera mortality in the Bengal region. Parameters are inferred with a recently developed sequential Monte Carlo method for likelihood maximization in partially observed Markov processes. Results indicate that the hydrological regime is a major driver of the seasonal dynamics of cholera. Rainfall tends to buffer the propagation of the disease in wet regions due to the longer residence times of water in the environment and an associated dilution effect, whereas it enhances cholera resurgence in dry regions. Moreover, the dynamics of the environmental water reservoir determine whether the seasonality is unimodal or bimodal, as well as its phase relative to the monsoon. Thus, the full range of seasonal patterns can be explained based solely on the local variation of rainfall and temperature. Given the close connection between cholera seasonality and environmental conditions, a deeper understanding of the underlying mechanisms would allow the better management and planning of public health policies with respect to climate variability and climate change.

  4. Correlation of shoulder range of motion limitations at discharge with limitations in activities and participation one year later in persons with spinal cord injury.

    Science.gov (United States)

    Eriks-Hoogland, Inge E; de Groot, Sonja; Post, Marcel W M; van der Woude, Lucas H V

    2011-02-01

    To study the correlation between limited shoulder range of motion in persons with spinal cord injury at discharge and the performance of activities, wheeling performance, transfers and participation one year later. Multicentre prospective cohort study. A total of 146 newly injured subjects with spinal cord injury. Shoulder range of motion was measured at discharge. One year later, Functional Independence Measure (FIM), transfer ability, wheelchair circuit and Physical Activity Scale for Individuals with Physical Disabilities (PASIPD) were assessed. Corrections were made for possible confounding factors (age, gender, level and completeness of injury, time since injury and shoulder pain). All subjects with limited shoulder range of motion at discharge had a lower FIM motor score and were less likely (total group 5 times, and subjects with tetraplegia 10 times less likely) to be able to perform an independent transfer one year later. Subjects with limited shoulder range of motion in the total group needed more time to complete the wheelchair circuit. No significant associations with the PASIPD were found in either group. Persons with spinal cord injury and limited shoulder range of motion at discharge are more limited in their activities one year later than those without limited shoulder range of motion.

  5. Simulating range-wide population and breeding habitat dynamics for an endangered woodland warbler in the face of uncertainty

    Science.gov (United States)

    Adam Duarte,; Hatfield, Jeffrey; Todd M. Swannack,; Michael R. J. Forstner,; M. Clay Green,; Floyd W. Weckerly,

    2015-01-01

    Population viability analyses provide a quantitative approach that seeks to predict the possible future status of a species of interest under different scenarios and, therefore, can be important components of large-scale species’ conservation programs. We created a model and simulated range-wide population and breeding habitat dynamics for an endangered woodland warbler, the golden-cheeked warbler (Setophaga chrysoparia). Habitat-transition probabilities were estimated across the warbler's breeding range by combining National Land Cover Database imagery with multistate modeling. Using these estimates, along with recently published demographic estimates, we examined if the species can remain viable into the future given the current conditions. Lastly, we evaluated if protecting a greater amount of habitat would increase the number of warblers that can be supported in the future by systematically increasing the amount of protected habitat and comparing the estimated terminal carrying capacity at the end of 50 years of simulated habitat change. The estimated habitat-transition probabilities supported the hypothesis that habitat transitions are unidirectional, whereby habitat is more likely to diminish than regenerate. The model results indicated population viability could be achieved under current conditions, depending on dispersal. However, there is considerable uncertainty associated with the population projections due to parametric uncertainty. Model results suggested that increasing the amount of protected lands would have a substantial impact on terminal carrying capacities at the end of a 50-year simulation. Notably, this study identifies the need for collecting the data required to estimate demographic parameters in relation to changes in habitat metrics and population density in multiple regions, and highlights the importance of establishing a common definition of what constitutes protected habitat, what management goals are suitable within those protected

  6. A High Dynamic-Range Beam Position Measurement System for ELSA-2

    CERN Document Server

    Balleyguier, P; Guimbal, P; Borrion, H

    2003-01-01

    New beamlines are presently under construction for ELSA, a 20 MeV electron linac located at Bruyères-le-Châtel. These lines need a beam position measurement system filling the following requirements: small footprint, wide dynamic range, single-bunch/multi-bunch capability, simple design. We designed a compact 4-stripline sensor and an electronic treatment chain based on logarithmic amplifiers. This paper presents the design, cold and hot test results.

  7. Wide and Fast Wavelength-Swept Fiber Laser Based on Dispersion Tuning for Dynamic Sensing

    Directory of Open Access Journals (Sweden)

    Shinji Yamashita

    2009-01-01

    Full Text Available We have developed a unique wide and fast wavelength-swept fiber laser for dynamic and accurate fiber sensing. The wavelength tuning is based on the dispersion tuning technique, which simply modulates the loss/gain in the dispersive laser cavity. By using wideband semiconductor optical amplifiers (SOAs, the sweep range could be as wide as ∼180 nm. Since the cavity contains no mechanical components, such as tunable filters, we could achieve very high sweep rate, as high as ∼200 kHz. We have realized the swept lasers at three wavelength bands, 1550 nm, 1300 nm, and 800 nm, using SOAs along with erbium-doped fiber amplifiers (EDFAs, and in two laser configurations, ring and linear ones. We also succeeded in applying the swept laser for a dynamic fiber-Bragg grating (FBG sensor system. In this paper, we review our researches on the wide and fast wavelength-swept fiber lasers.

  8. Highly Sensitive and Wide-Dynamic-Range Multichannel Optical-Fiber pH Sensor Based on PWM Technique

    OpenAIRE

    Md. Rajibur Rahaman Khan; Shin-Won Kang

    2016-01-01

    In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal?s pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The...

  9. Soil Compressibility Models for a Wide Stress Range

    KAUST Repository

    Chong, Song-Hun

    2016-03-03

    Soil compressibility models with physically correct asymptotic void ratios are required to analyze situations that involve a wide stress range. Previously suggested models and other functions are adapted to satisfy asymptotic void ratios at low and high stress levels; all updated models involve four parameters. Compiled consolidation data for remolded and natural clays are used to test the models and to develop correlations between model parameters and index properties. Models can adequately fit soil compression data for a wide range of stresses and soil types; in particular, models that involve the power of the stress σ\\'β display higher flexibility to capture the brittle response of some natural soils. The use of a single continuous function avoids numerical discontinuities or the need for ad hoc procedures to determine the yield stress. The tangent stiffness-readily computed for all models-should not be mistaken for the small-strain constant-fabric stiffness. © 2016 American Society of Civil Engineers.

  10. High dynamic range image acquisition based on multiplex cameras

    Science.gov (United States)

    Zeng, Hairui; Sun, Huayan; Zhang, Tinghua

    2018-03-01

    High dynamic image is an important technology of photoelectric information acquisition, providing higher dynamic range and more image details, and it can better reflect the real environment, light and color information. Currently, the method of high dynamic range image synthesis based on different exposure image sequences cannot adapt to the dynamic scene. It fails to overcome the effects of moving targets, resulting in the phenomenon of ghost. Therefore, a new high dynamic range image acquisition method based on multiplex cameras system was proposed. Firstly, different exposure images sequences were captured with the camera array, using the method of derivative optical flow based on color gradient to get the deviation between images, and aligned the images. Then, the high dynamic range image fusion weighting function was established by combination of inverse camera response function and deviation between images, and was applied to generated a high dynamic range image. The experiments show that the proposed method can effectively obtain high dynamic images in dynamic scene, and achieves good results.

  11. Localization of Brain Natriuretic Peptide Immunoreactivity in Rat Spinal Cord

    Directory of Open Access Journals (Sweden)

    Essam M Abdelalim

    2016-12-01

    Full Text Available Brain natriuretic peptide (BNP exerts its functions through natriuretic peptide receptors. Recently, BNP has been shown to be involved in a wide range of functions. Previous studies reported BNP expression in the sensory afferent fibers in the dorsal horn of the spinal cord. However, BNP expression and function in the neurons of the central nervous system are still controversial. Therefore, in this study, we investigated BNP expression in the rat spinal cord in detail using RT-PCR and immunohistochemistry. RT-PCR analysis showed that BNP mRNA was present in the spinal cord and DRG. BNP immunoreactivity was observed in different structures of the spinal cord, including the neuronal cell bodies and neuronal processes. BNP immunoreactivity was observed in the dorsal horn of the spinal cord and in the neurons of the intermediate column and ventral horn. Double-immunolabeling showed a high level of BNP expression in the afferent fibers (laminae I-II labeled with calcitonin gene-related peptide (CGRP, suggesting BNP involvement in sensory function. In addition, BNP was co-localized with CGRP and choline acetyltransferase in the motor neurons of the ventral horn. Together, these results indicate that BNP is expressed in sensory and motor systems of the spinal cord, suggesting its involvement in several biological actions on sensory and motor neurons via its binding to NPR-A and/or NPR-B in the DRG and spinal cord.

  12. Pediatric spinal infections

    Directory of Open Access Journals (Sweden)

    Raj Kumar

    2014-01-01

    Full Text Available The infections of the spinal axis in children are rare when compared with adults. They encompass a large spectrum of diseases ranging from relatively benign diskitis to spinal osteomyleitis and to the rapidly progressive, rare, and potentially devastating spinal epidural, subdural, and intramedullary spinal cord infections. We present a comprehensive review of the literature pertaining to these uncommon entities, in light of our experience from northern India. The most prevalent pediatric spinal infection in Indian scenario is tuberculosis, where an extradural involvement is more common than intradural. The craniovertebral junction is not an uncommon site of involvement in children of our milieu. The majority of pyogenic infections of pediatric spine are associated with congenital neuro-ectodermal defects such as congenital dermal sinus. The clinico-radiological findings of various spinal infections commonly overlap. Hence the endemicity of certain pathogens should be given due consideration, while considering the differential diagnosis. However, early suspicion, rapid diagnosis, and prompt treatment are the key factors in avoiding neurological morbidity and deformity in a growing child.

  13. Doped silicene: Evidence of a wide stability range

    KAUST Repository

    Cheng, Yingchun; Zhu, Zhiyong; Schwingenschlö gl, Udo

    2011-01-01

    to the carrier concentration, it is stable in a wide doping range. The frequencies of the E2g-Γ and A′-K Raman modes can be used to probe the carrier concentration. In addition, the phonon dispersion displays Kohn anomalies at the Γ and K points which are reduced

  14. Design, commissioning and operational results of wide dynamic range BPM switched electrode electronics

    International Nuclear Information System (INIS)

    Powers, T.; Doolittle, L.; Ursic, R.; Wagner, J.

    1997-01-01

    The Continuous Electron Beam Accelerator Facility (CEBAF) is a high-intensity, continuous-wave electron accelerator for nuclear physics. Total acceleration of 4 GeV is achieved by recirculating the beam through two 400-MeV linacs. The operating currents over which the linac beam position monitoring system must meet specifications are 1 μA to 1000 μA. A system was developed in 1994 and installed in the spring of 1995 that switches four electrode signals at 120 kHz through two signal-conditioning chains that use computer-controlled variable gain amplifiers with a dynamic range greater than 80 dB. The system timing was tuned to the machine recirculation period of 4.2 μs so that components of the multipass beam could be resolved in the linacs. Other features of this VME-based system include long-term stability and high-speed data acquisition, which make it suitable for use as both a time-domain diagnostic tool and as part of a variety of beam feedback systems. The computer interface has enough control over the hardware to make a thorough self-calibration and verification-of-operation routine possible. copyright 1997 American Institute of Physics

  15. Modulation of neuronal dynamic range using two different adaptation mechanisms

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2017-01-01

    Full Text Available The capability of neurons to discriminate between intensity of external stimulus is measured by its dynamic range. A larger dynamic range indicates a greater probability of neuronal survival. In this study, the potential roles of adaptation mechanisms (ion currents in modulating neuronal dynamic range were numerically investigated. Based on the adaptive exponential integrate-and-fire model, which includes two different adaptation mechanisms, i.e. subthreshold and suprathreshold (spike-triggered adaptation, our results reveal that the two adaptation mechanisms exhibit rather different roles in regulating neuronal dynamic range. Specifically, subthreshold adaptation acts as a negative factor that observably decreases the neuronal dynamic range, while suprathreshold adaptation has little influence on the neuronal dynamic range. Moreover, when stochastic noise was introduced into the adaptation mechanisms, the dynamic range was apparently enhanced, regardless of what state the neuron was in, e.g. adaptive or non-adaptive. Our model results suggested that the neuronal dynamic range can be differentially modulated by different adaptation mechanisms. Additionally, noise was a non-ignorable factor, which could effectively modulate the neuronal dynamic range.

  16. The analysis on dynamic range of industrial CT system

    International Nuclear Information System (INIS)

    Wang Huiqian; Wang Jue; Tan Hui

    2011-01-01

    Concerning the limitations of the definition of the dynamic range of industrial computed tomography (ICT) system, it researches the definition, measuring method and influencing factors of the dynamic range of industrial computed tomography (ICT) system from the concept of quantization and system. First, the character of the input-output curve was analyzed, and the method of obtaining the dynamic range of industrial computed tomography (ICT) system was proposed. Then, an experiment model was designed to gain dynamic range, based on 6 MeV high-energy industrial computed tomography (ICT) system. The results show that the larger the photosurface is, the smaller the dynamic range is, when the other parameters are unchanged. (authors)

  17. Multi-exposure high dynamic range image synthesis with camera shake correction

    Science.gov (United States)

    Li, Xudong; Chen, Yongfu; Jiang, Hongzhi; Zhao, Huijie

    2017-10-01

    Machine vision plays an important part in industrial online inspection. Owing to the nonuniform illuminance conditions and variable working distances, the captured image tends to be over-exposed or under-exposed. As a result, when processing the image such as crack inspection, the algorithm complexity and computing time increase. Multiexposure high dynamic range (HDR) image synthesis is used to improve the quality of the captured image, whose dynamic range is limited. Inevitably, camera shake will result in ghost effect, which blurs the synthesis image to some extent. However, existed exposure fusion algorithms assume that the input images are either perfectly aligned or captured in the same scene. These assumptions limit the application. At present, widely used registration based on Scale Invariant Feature Transform (SIFT) is usually time consuming. In order to rapidly obtain a high quality HDR image without ghost effect, we come up with an efficient Low Dynamic Range (LDR) images capturing approach and propose a registration method based on ORiented Brief (ORB) and histogram equalization which can eliminate the illumination differences between the LDR images. The fusion is performed after alignment. The experiment results demonstrate that the proposed method is robust to illumination changes and local geometric distortion. Comparing with other exposure fusion methods, our method is more efficient and can produce HDR images without ghost effect by registering and fusing four multi-exposure images.

  18. Spinal cord injuries among paragliders in Norway.

    Science.gov (United States)

    Rekand, T; Schaanning, E E; Varga, V; Schattel, U; Gronning, M

    2008-06-01

    A national retrospective descriptive study. To study the clinical effects of spinal cord injuries (SCIs) caused by paragliding accidents in Norway. Spinal cord units at Haukeland University Hospital, Sunnaas Rehabilitation Hospital and St Olav Hospital in Norway. We studied the medical files for nine patients with SCI caused by paragliding accidents to evaluate the circumstances of the accidents, and clinical effects of injury. We obtained the data from hospital patient files at all three spinal units in Norway and crosschecked them through the Norwegian Paragliding Association's voluntary registry for injuries. All patients were hospitalized from 1997 to 2006, eight men and one woman, with mean age 30.7 years. The causes of the accidents were landing problems combined with unexpected wind whirls, technical problems and limited experience with unexpected events. All patients contracted fractures in the thoracolumbal junction of the spine, most commonly at the L1 level. At clinical follow-up, all patients presented clinically incomplete SCI (American Spinal Injury Association impairment scores B-D). Their main health problems differed widely, ranging from urinary and sexual disturbances to neuropathic pain and loss of motor functioning. Only three patients returned to full-time employment after rehabilitation. Paragliding accidents cause spinal fractures predominantly in the thoracolumbal junction with subsequent SCIs and increased morbidity. All patients experienced permanent health problems that influenced daily activities and required long-time clinical follow-up and medical intervention. Better education in landing techniques and understanding of aerodynamics may reduce the risk of paragliding accidents.

  19. Iso-effect table for radiation tolerance of the human spinal cord

    International Nuclear Information System (INIS)

    Cohen, L.; Creditor, M.

    1981-01-01

    Available literature on radiation injury to the human spinal cord was collected into a comprehensive data set relating the incidence of myelopathy to dosage, number of fractions and total treatment time. The data was analyzed using a search program (RAD3) to derive best-fitting cell kinetic parameters on the assumption that radiation myelopathy arises from cellular depletion in the irradiated tissues. From these parameters iso-effect tables were constructed for a wide range of treatment schedules, including daily treatment as well as fractionation at longer intervals. The tables provide a set of limiting doses, above which the risk of radiation injury to the spinal cord becomes substantial. General application of NSD tolerance limits could lead to systematic overdosage of the spinal cord, especially with large individual fractions or short treatment times. We conclude that the computed iso-effect tables provide a more reliable clinical guide than conventional time-dose equations

  20. Formalin-induced behavioural hypersensitivity and neuronal hyperexcitability are mediated by rapid protein synthesis at the spinal level

    Science.gov (United States)

    Asante, Curtis O; Wallace, Victoria C; Dickenson, Anthony H

    2009-01-01

    Background The mammalian target of rapamycin (mTOR) is a key regulator of mRNA translation whose action can be inhibited by the drug rapamycin. Forms of long-term plasticity require protein synthesis and evidence indicates that mRNA in dendrites, axon terminals and cell bodies is essential for long-term synaptic plasticity. Specific to pain, shifts in pain thresholds and responsiveness are an expression of neuronal plasticity and this likely contributes to persistent pain. We investigated this by inhibiting the activity of mTOR with rapamycin at the spinal level, of rats that were subjected to the formalin test, using both behavioural and electrophysiological techniques. Results For in vivo electrophysiology, Sprague Dawley rats were fully anaesthetised and single-unit extracellular recordings were obtained from lamina V wide dynamic range (WDR) dorsal horn spinal neurones at the region where input is received from the hind paw. Neuronal responses from naive rats showed that rapamycin-sensitive pathways were important in nociceptive-specific C-fibre mediated transmission onto WDR neurones as well mechanically-evoked responses since rapamycin was effective in attenuating these measures. Formalin solution was injected into the hind paw prior to which, rapamycin or vehicle was applied directly onto the exposed spinal cord. When rapamycin was applied to the spinal cord prior to hind paw formalin injection, there was a significant attenuation of the prolonged second phase of the formalin test, which comprises continuing afferent input to the spinal cord, neuronal hyperexcitability and an activated descending facilitatory drive from the brainstem acting on spinal neurones. In accordance with electrophysiological data, behavioural studies showed that rapamycin attenuated behavioural hypersensitivity elicited by formalin injection into the hind paw. Conclusion We conclude that mTOR has a role in maintaining persistent pain states via mRNA translation and thus protein

  1. Formalin-induced behavioural hypersensitivity and neuronal hyperexcitability are mediated by rapid protein synthesis at the spinal level

    Directory of Open Access Journals (Sweden)

    Wallace Victoria C

    2009-06-01

    Full Text Available Abstract Background The mammalian target of rapamycin (mTOR is a key regulator of mRNA translation whose action can be inhibited by the drug rapamycin. Forms of long-term plasticity require protein synthesis and evidence indicates that mRNA in dendrites, axon terminals and cell bodies is essential for long-term synaptic plasticity. Specific to pain, shifts in pain thresholds and responsiveness are an expression of neuronal plasticity and this likely contributes to persistent pain. We investigated this by inhibiting the activity of mTOR with rapamycin at the spinal level, of rats that were subjected to the formalin test, using both behavioural and electrophysiological techniques. Results For in vivo electrophysiology, Sprague Dawley rats were fully anaesthetised and single-unit extracellular recordings were obtained from lamina V wide dynamic range (WDR dorsal horn spinal neurones at the region where input is received from the hind paw. Neuronal responses from naive rats showed that rapamycin-sensitive pathways were important in nociceptive-specific C-fibre mediated transmission onto WDR neurones as well mechanically-evoked responses since rapamycin was effective in attenuating these measures. Formalin solution was injected into the hind paw prior to which, rapamycin or vehicle was applied directly onto the exposed spinal cord. When rapamycin was applied to the spinal cord prior to hind paw formalin injection, there was a significant attenuation of the prolonged second phase of the formalin test, which comprises continuing afferent input to the spinal cord, neuronal hyperexcitability and an activated descending facilitatory drive from the brainstem acting on spinal neurones. In accordance with electrophysiological data, behavioural studies showed that rapamycin attenuated behavioural hypersensitivity elicited by formalin injection into the hind paw. Conclusion We conclude that mTOR has a role in maintaining persistent pain states via m

  2. Non-contiguous spinal injury in cervical spinal trauma: evaluation with cervical spine MRI

    International Nuclear Information System (INIS)

    Choi, Soo Jung; Shin, Myung Jin; Kim, Sung Moon; Bae, Sang Jin

    2004-01-01

    We wished to evaluate the incidence of non-contiguous spinal injury in the cervicothoracic junction (CTJ) or the upper thoracic spines on cervical spinal MR images in the patients with cervical spinal injuries. Seventy-five cervical spine MR imagings for acute cervical spinal injury were retrospectively reviewed (58 men and 17 women, mean age: 35.3, range: 18-81 years). They were divided into three groups based on the mechanism of injury; axial compression, hyperflexion or hyperextension injury, according to the findings on the MR and CT images. On cervical spine MR images, we evaluated the presence of non-contiguous spinal injury in the CTJ or upper thoracic spine with regard to the presence of marrow contusion or fracture, ligament injury, traumatic disc herniation and spinal cord injury. Twenty-one cases (28%) showed CTJ or upper thoracic spinal injuries (C7-T5) on cervical spinal MR images that were separated from the cervical spinal injuries. Seven of 21 cases revealed overt fractures in the CTJs or upper thoracic spines. Ligament injury in these regions was found in three cases. Traumatic disc herniation and spinal cord injury in these regions were shown in one and two cases, respectively. The incidence of the non-contiguous spinal injuries in CTJ or upper thoracic spines was higher in the axial compression injury group (35.5%) than in the hyperflexion injury group (26.9%) or the hyperextension (25%) injury group. However, there was no statistical significance (ρ > 0.05). Cervical spinal MR revealed non-contiguous CTJ or upper thoracic spinal injuries in 28% of the patients with cervical spinal injury. The mechanism of cervical spinal injury did not significantly affect the incidence of the non-contiguous CTJ or upper thoracic spinal injury

  3. Non-contiguous spinal injury in cervical spinal trauma: evaluation with cervical spine MRI

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Soo Jung; Shin, Myung Jin; Kim, Sung Moon [University of Ulsan College of Medicine, Seoul (Korea, Republic of); Bae, Sang Jin [Sanggyepaik Hospital, Inje University, Seoul (Korea, Republic of)

    2004-12-15

    We wished to evaluate the incidence of non-contiguous spinal injury in the cervicothoracic junction (CTJ) or the upper thoracic spines on cervical spinal MR images in the patients with cervical spinal injuries. Seventy-five cervical spine MR imagings for acute cervical spinal injury were retrospectively reviewed (58 men and 17 women, mean age: 35.3, range: 18-81 years). They were divided into three groups based on the mechanism of injury; axial compression, hyperflexion or hyperextension injury, according to the findings on the MR and CT images. On cervical spine MR images, we evaluated the presence of non-contiguous spinal injury in the CTJ or upper thoracic spine with regard to the presence of marrow contusion or fracture, ligament injury, traumatic disc herniation and spinal cord injury. Twenty-one cases (28%) showed CTJ or upper thoracic spinal injuries (C7-T5) on cervical spinal MR images that were separated from the cervical spinal injuries. Seven of 21 cases revealed overt fractures in the CTJs or upper thoracic spines. Ligament injury in these regions was found in three cases. Traumatic disc herniation and spinal cord injury in these regions were shown in one and two cases, respectively. The incidence of the non-contiguous spinal injuries in CTJ or upper thoracic spines was higher in the axial compression injury group (35.5%) than in the hyperflexion injury group (26.9%) or the hyperextension (25%) injury group. However, there was no statistical significance ({rho} > 0.05). Cervical spinal MR revealed non-contiguous CTJ or upper thoracic spinal injuries in 28% of the patients with cervical spinal injury. The mechanism of cervical spinal injury did not significantly affect the incidence of the non-contiguous CTJ or upper thoracic spinal injury.

  4. High efficiency RF amplifier development over wide dynamic range for accelerator application

    Science.gov (United States)

    Mishra, Jitendra Kumar; Ramarao, B. V.; Pande, Manjiri M.; Joshi, Gopal; Sharma, Archana; Singh, Pitamber

    2017-10-01

    Superconducting (SC) cavities in an accelerating section are designed to have the same geometrical velocity factor (βg). For these cavities, Radio Frequency (RF) power needed to accelerate charged particles varies with the particle velocity factor (β). RF power requirement from one cavity to other can vary by 2-5 dB within the accelerating section depending on the energy gain in the cavity and beam current. In this paper, we have presented an idea to improve operating efficiency of the SC RF accelerators using envelope tracking technique. A study on envelope tracking technique without feedback is carried out on a 1 kW, 325 MHz, class B (conduction angle of 180 degrees) tuned load power amplifier (PA). We have derived expressions for the efficiency and power output for tuned load amplifier operating on the envelope tracking technique. From the derived expressions, it is observed that under constant load resistance to the device (MOSFET), optimum amplifier efficiency is invariant whereas output power varies with the square of drain bias voltage. Experimental results on 1 kW PA module show that its optimum efficiency is always greater than 62% with variation less than 5% from mean value over 7 dB dynamic range. Low power amplifier modules are the basic building block for the high power amplifiers. Therefore, results for 1 kW PA modules remain valid for the high power solid state amplifiers built using these PA modules. The SC RF accelerators using these constant efficiency power amplifiers can improve overall accelerator efficiency.

  5. Spinal Cord Independence Measure, version III: applicability to the UK spinal cord injured population.

    Science.gov (United States)

    Glass, Clive A; Tesio, Luigi; Itzkovich, Malka; Soni, Bakul M; Silva, Pedro; Mecci, Munawar; Chadwick, Raymond; el Masry, Waghi; Osman, Aheed; Savic, Gordana; Gardner, Brian; Bergström, Ebba; Catz, Amiram

    2009-09-01

    To examine the validity, reliability and usefulness of the Spinal Cord Independence Measure for the UK spinal cord injury population. Multi-centre cohort study. Four UK regional spinal cord injury centres. Eighty-six people with spinal cord injury. Spinal Cord Independence Measure and Functional Independence Measure on admission analysed using inferential statistics, and Rasch analysis of Spinal Cord Independence Measure. Internal consistency, inter-rater reliability, discriminant validity; Spinal Cord Independence Measure subscale match between distribution of item difficulty and patient ability measurements; reliability of patient ability measures; fit of data to Rasch model; unidimensionality of subscales; hierarchical ordering of categories within items; differential item functioning across patient groups. Scale reliability (kappa coefficients range 0.491-0.835; (p Spinal Cord Independence Measure subscales compatible with stringent Rasch requirements; mean infit indices high; distinct strata of abilities identified; most thresholds ordered; item hierarchy stable across clinical groups and centres. Misfit and differences in item hierarchy identified. Difficulties assessing central cord injuries highlighted. Conventional statistical and Rasch analyses justify the use of the Spinal Cord Independence Measure in clinical practice and research in the UK. Cross-cultural validity may be further improved.

  6. Dynamic range meter for radiofrequency amplifiers

    Directory of Open Access Journals (Sweden)

    Drozd S. S.

    2009-04-01

    Full Text Available The new measurement setup having increased on 20…30 dB the own dynamic range in comparison with the standard circuit of the dynamic range meter is offered and the rated value of an error bringing by setup in the worst case does not exceed ± 2,8 dB. The measurement setup can be applied also to determinate levels of intermodulation components average power amplifiers and powerful amplifiers of a low-frequency at replacement of the quartz filter on meeting low-frequency the LC-filter and the spectrum analyzer.

  7. Post-traumatic recto-spinal fistula

    International Nuclear Information System (INIS)

    Lantsberg, L.; Greenberg, G.; Laufer, L.; Hertzanu, Y.

    2000-01-01

    Acquired recto-spinal fistula has been described elsewhere as a rare complication of colorectal malignancy and Crohn's enterocolitis. We treated a young man who developed a recto-spinal fistula as a result of a high fall injury. The patient presented with meningeal signs, sepsis and perianal laceration. Computerized axial tomography revealed air in the supersellar cistern. Gastrografin enema showed that contrast material was leaking from the rectum into the spinal canal. Surgical management included a diverting sigmoid colostomy, sacral bone curettage and wide presacral drainage. To the best of our knowledge, rectospinal fistula of traumatic origin has not been previously reported in the English literature. (orig.)

  8. Post-traumatic recto-spinal fistula

    Energy Technology Data Exchange (ETDEWEB)

    Lantsberg, L.; Greenberg, G. [Department of Surgery A, Soroka University Medical Center, Beer-Sheva (Israel); Laufer, L.; Hertzanu, Y. [Department of Diagnostic Radiology, Soroka University Medical Center, Beer-Sheva (Israel)

    2000-01-01

    Acquired recto-spinal fistula has been described elsewhere as a rare complication of colorectal malignancy and Crohn's enterocolitis. We treated a young man who developed a recto-spinal fistula as a result of a high fall injury. The patient presented with meningeal signs, sepsis and perianal laceration. Computerized axial tomography revealed air in the supersellar cistern. Gastrografin enema showed that contrast material was leaking from the rectum into the spinal canal. Surgical management included a diverting sigmoid colostomy, sacral bone curettage and wide presacral drainage. To the best of our knowledge, rectospinal fistula of traumatic origin has not been previously reported in the English literature. (orig.)

  9. Territorial dynamics and stable home range formation for central place foragers.

    Directory of Open Access Journals (Sweden)

    Jonathan R Potts

    Full Text Available Uncovering the mechanisms behind territory formation is a fundamental problem in behavioural ecology. The broad nature of the underlying conspecific avoidance processes are well documented across a wide range of taxa. Scent marking in particular is common to a large range of terrestrial mammals and is known to be fundamental for communication. However, despite its importance, exact quantification of the time-scales over which scent cues and messages persist remains elusive. Recent work by the present authors has begun to shed light on this problem by modelling animals as random walkers with scent-mediated interaction processes. Territories emerge as dynamic objects that continually change shape and slowly move without settling to a fixed location. As a consequence, the utilisation distribution of such an animal results in a slowly increasing home range, as shown for urban foxes (Vulpes vulpes. For certain other species, however, home ranges reach a stable state. The present work shows that stable home ranges arise when, in addition to scent-mediated conspecific avoidance, each animal moves as a central place forager. That is, the animal's movement has a random aspect but is also biased towards a fixed location, such as a den or nest site. Dynamic territories emerge but the probability distribution of the territory border locations reaches a steady state, causing stable home ranges to emerge from the territorial dynamics. Approximate analytic expressions for the animal's probability density function are derived. A programme is given for using these expressions to quantify both the strength of the animal's movement bias towards the central place and the time-scale over which scent messages persist. Comparisons are made with previous theoretical work modelling central place foragers with conspecific avoidance. Some insights into the mechanisms behind allometric scaling laws of animal space use are also given.

  10. Targeting Lumbar Spinal Neural Circuitry by Epidural Stimulation to Restore Motor Function After Spinal Cord Injury.

    Science.gov (United States)

    Minassian, Karen; McKay, W Barry; Binder, Heinrich; Hofstoetter, Ursula S

    2016-04-01

    Epidural spinal cord stimulation has a long history of application for improving motor control in spinal cord injury. This review focuses on its resurgence following the progress made in understanding the underlying neurophysiological mechanisms and on recent reports of its augmentative effects upon otherwise subfunctional volitional motor control. Early work revealed that the spinal circuitry involved in lower-limb motor control can be accessed by stimulating through electrodes placed epidurally over the posterior aspect of the lumbar spinal cord below a paralyzing injury. Current understanding is that such stimulation activates large-to-medium-diameter sensory fibers within the posterior roots. Those fibers then trans-synaptically activate various spinal reflex circuits and plurisegmentally organized interneuronal networks that control more complex contraction and relaxation patterns involving multiple muscles. The induced change in responsiveness of this spinal motor circuitry to any residual supraspinal input via clinically silent translesional neural connections that have survived the injury may be a likely explanation for rudimentary volitional control enabled by epidural stimulation in otherwise paralyzed muscles. Technological developments that allow dynamic control of stimulation parameters and the potential for activity-dependent beneficial plasticity may further unveil the remarkable capacity of spinal motor processing that remains even after severe spinal cord injuries.

  11. On Dynamic Range Limitations of CMOS Current Conveyors

    DEFF Research Database (Denmark)

    Bruun, Erik

    1999-01-01

    frequency band and for the situation where the conveyor is used over the full bandwidth achievable. Finally, the optimisation of the current input range is related to the distortion characteristics and it is pointed out that to a first order approximation the distortion is independent of the current range.......This paper is concerned with the dynamic range of continuous time CMOS current mode circuits. As a representative current mode device a class AB current conveyor is examined. First, the voltage input range of the high impedance Y input is investigated. Next, the current input range of the low...... impedance X input is investigated. It is compared to the thermal noise in the X to Z signal path in order to evaluate the dynamic range, and the dependencies of the dynamic range on the supply voltage and the transistor lay-out is derived, both for the situation where the conveyor is used over a narrow...

  12. HEVC for high dynamic range services

    Science.gov (United States)

    Kim, Seung-Hwan; Zhao, Jie; Misra, Kiran; Segall, Andrew

    2015-09-01

    Displays capable of showing a greater range of luminance values can render content containing high dynamic range information in a way such that the viewers have a more immersive experience. This paper introduces the design aspects of a high dynamic range (HDR) system, and examines the performance of the HDR processing chain in terms of compression efficiency. Specifically it examines the relation between recently introduced Society of Motion Picture and Television Engineers (SMPTE) ST 2084 transfer function and the High Efficiency Video Coding (HEVC) standard. SMPTE ST 2084 is designed to cover the full range of an HDR signal from 0 to 10,000 nits, however in many situations the valid signal range of actual video might be smaller than SMPTE ST 2084 supported range. The above restricted signal range results in restricted range of code values for input video data and adversely impacts compression efficiency. In this paper, we propose a code value remapping method that extends the restricted range code values into the full range code values so that the existing standards such as HEVC may better compress the video content. The paper also identifies related non-normative encoder-only changes that are required for remapping method for a fair comparison with anchor. Results are presented comparing the efficiency of the current approach versus the proposed remapping method for HM-16.2.

  13. Specific involvement of atypical PKCζ/PKMζ in spinal persistent nociceptive processing following peripheral inflammation in rat

    Directory of Open Access Journals (Sweden)

    Marchand Fabien

    2011-11-01

    Full Text Available Abstract Background Central sensitization requires the activation of various intracellular signalling pathways within spinal dorsal horn neurons, leading to a lowering of activation threshold and enhanced responsiveness of these cells. Such plasticity contributes to the manifestation of chronic pain states and displays a number of features of long-term potentiation (LTP, a ubiquitous neuronal mechanism of increased synaptic strength. Here we describe the role of a novel pathway involving atypical PKCζ/PKMζ in persistent spinal nociceptive processing, previously implicated in the maintenance of late-phase LTP. Results Using both behavioral tests and in vivo electrophysiology in rats, we show that inhibition of this pathway, via spinal delivery of a myristoylated protein kinase C-ζ pseudo-substrate inhibitor, reduces both pain-related behaviors and the activity of deep dorsal horn wide dynamic range neurons (WDRs following formalin administration. In addition, Complete Freund's Adjuvant (CFA-induced mechanical and thermal hypersensitivity was also reduced by inhibition of PKCζ/PKMζ activity. Importantly, this inhibition did not affect acute pain or locomotor behavior in normal rats and interestingly, did not inhibited mechanical allodynia and hyperalgesia in neuropathic rats. Pain-related behaviors in both inflammatory models coincided with increased phosphorylation of PKCζ/PKMζ in dorsal horn neurons, specifically PKMζ phosphorylation in formalin rats. Finally, inhibition of PKCζ/PKMζ activity decreased the expression of Fos in response to formalin and CFA in both superficial and deep laminae of the dorsal horn. Conclusions These results suggest that PKCζ, especially PKMζ isoform, is a significant factor involved in spinal persistent nociceptive processing, specifically, the manifestation of chronic pain states following peripheral inflammation.

  14. Dynamic Range Across Music Genres and the Perception of Dynamic Compression in Hearing-Impaired Listeners

    Directory of Open Access Journals (Sweden)

    Martin Kirchberger

    2016-02-01

    Full Text Available Dynamic range compression serves different purposes in the music and hearing-aid industries. In the music industry, it is used to make music louder and more attractive to normal-hearing listeners. In the hearing-aid industry, it is used to map the variable dynamic range of acoustic signals to the reduced dynamic range of hearing-impaired listeners. Hence, hearing-aided listeners will typically receive a dual dose of compression when listening to recorded music. The present study involved an acoustic analysis of dynamic range across a cross section of recorded music as well as a perceptual study comparing the efficacy of different compression schemes. The acoustic analysis revealed that the dynamic range of samples from popular genres, such as rock or rap, was generally smaller than the dynamic range of samples from classical genres, such as opera and orchestra. By comparison, the dynamic range of speech, based on recordings of monologues in quiet, was larger than the dynamic range of all music genres tested. The perceptual study compared the effect of the prescription rule NAL-NL2 with a semicompressive and a linear scheme. Music subjected to linear processing had the highest ratings for dynamics and quality, followed by the semicompressive and the NAL-NL2 setting. These findings advise against NAL-NL2 as a prescription rule for recorded music and recommend linear settings.

  15. Dynamic Range Across Music Genres and the Perception of Dynamic Compression in Hearing-Impaired Listeners

    Science.gov (United States)

    Kirchberger, Martin

    2016-01-01

    Dynamic range compression serves different purposes in the music and hearing-aid industries. In the music industry, it is used to make music louder and more attractive to normal-hearing listeners. In the hearing-aid industry, it is used to map the variable dynamic range of acoustic signals to the reduced dynamic range of hearing-impaired listeners. Hence, hearing-aided listeners will typically receive a dual dose of compression when listening to recorded music. The present study involved an acoustic analysis of dynamic range across a cross section of recorded music as well as a perceptual study comparing the efficacy of different compression schemes. The acoustic analysis revealed that the dynamic range of samples from popular genres, such as rock or rap, was generally smaller than the dynamic range of samples from classical genres, such as opera and orchestra. By comparison, the dynamic range of speech, based on recordings of monologues in quiet, was larger than the dynamic range of all music genres tested. The perceptual study compared the effect of the prescription rule NAL-NL2 with a semicompressive and a linear scheme. Music subjected to linear processing had the highest ratings for dynamics and quality, followed by the semicompressive and the NAL-NL2 setting. These findings advise against NAL-NL2 as a prescription rule for recorded music and recommend linear settings. PMID:26868955

  16. Dynamic Range Across Music Genres and the Perception of Dynamic Compression in Hearing-Impaired Listeners.

    Science.gov (United States)

    Kirchberger, Martin; Russo, Frank A

    2016-02-10

    Dynamic range compression serves different purposes in the music and hearing-aid industries. In the music industry, it is used to make music louder and more attractive to normal-hearing listeners. In the hearing-aid industry, it is used to map the variable dynamic range of acoustic signals to the reduced dynamic range of hearing-impaired listeners. Hence, hearing-aided listeners will typically receive a dual dose of compression when listening to recorded music. The present study involved an acoustic analysis of dynamic range across a cross section of recorded music as well as a perceptual study comparing the efficacy of different compression schemes. The acoustic analysis revealed that the dynamic range of samples from popular genres, such as rock or rap, was generally smaller than the dynamic range of samples from classical genres, such as opera and orchestra. By comparison, the dynamic range of speech, based on recordings of monologues in quiet, was larger than the dynamic range of all music genres tested. The perceptual study compared the effect of the prescription rule NAL-NL2 with a semicompressive and a linear scheme. Music subjected to linear processing had the highest ratings for dynamics and quality, followed by the semicompressive and the NAL-NL2 setting. These findings advise against NAL-NL2 as a prescription rule for recorded music and recommend linear settings. © The Author(s) 2016.

  17. High-dynamic-range coherent diffractive imaging: ptychography using the mixed-mode pixel array detector

    Energy Technology Data Exchange (ETDEWEB)

    Giewekemeyer, Klaus, E-mail: klaus.giewekemeyer@xfel.eu [European XFEL GmbH, Hamburg (Germany); Philipp, Hugh T. [Cornell University, Ithaca, NY (United States); Wilke, Robin N. [Georg-August-Universität Göttingen, Göttingen (Germany); Aquila, Andrew [European XFEL GmbH, Hamburg (Germany); Osterhoff, Markus [Georg-August-Universität Göttingen, Göttingen (Germany); Tate, Mark W.; Shanks, Katherine S. [Cornell University, Ithaca, NY (United States); Zozulya, Alexey V. [Deutsches Elektronen-Synchrotron DESY, Hamburg (Germany); Salditt, Tim [Georg-August-Universität Göttingen, Göttingen (Germany); Gruner, Sol M. [Cornell University, Ithaca, NY (United States); Cornell University, Ithaca, NY (United States); Kavli Institute of Cornell for Nanoscience, Ithaca, NY (United States); Mancuso, Adrian P. [European XFEL GmbH, Hamburg (Germany)

    2014-08-07

    The advantages of a novel wide dynamic range hard X-ray detector are demonstrated for (ptychographic) coherent X-ray diffractive imaging. Coherent (X-ray) diffractive imaging (CDI) is an increasingly popular form of X-ray microscopy, mainly due to its potential to produce high-resolution images and the lack of an objective lens between the sample and its corresponding imaging detector. One challenge, however, is that very high dynamic range diffraction data must be collected to produce both quantitative and high-resolution images. In this work, hard X-ray ptychographic coherent diffractive imaging has been performed at the P10 beamline of the PETRA III synchrotron to demonstrate the potential of a very wide dynamic range imaging X-ray detector (the Mixed-Mode Pixel Array Detector, or MM-PAD). The detector is capable of single photon detection, detecting fluxes exceeding 1 × 10{sup 8} 8-keV photons pixel{sup −1} s{sup −1}, and framing at 1 kHz. A ptychographic reconstruction was performed using a peak focal intensity on the order of 1 × 10{sup 10} photons µm{sup −2} s{sup −1} within an area of approximately 325 nm × 603 nm. This was done without need of a beam stop and with a very modest attenuation, while ‘still’ images of the empty beam far-field intensity were recorded without any attenuation. The treatment of the detector frames and CDI methodology for reconstruction of non-sensitive detector regions, partially also extending the active detector area, are described.

  18. Marine: a new wide range neutron monitoring system concept

    Energy Technology Data Exchange (ETDEWEB)

    Trama, J.C.; Lescop, B.; Lefevre, J.; Nguyen, T.; Sudres, C. [CEA Saclay, 91 - Gif sur Yvette (France). Dept. d' Electronique et d' Instrumentation Nucleaire; Pasdeloup, P. [Technicatome, 13 - Les Milles (France)

    2001-07-01

    In a Nuclear Power Plant, the developed power is proportional to the emitted neutron flux. The 10 to 11 decades measurement range from source to power generally needs 3 distinct neutron measurement chains to be monitored. A wide range neutron monitoring system may cover this range with only one sensor followed by adequate electronics. In the past this concept has been developed with an analogue technology which was presenting some drawbacks (slow log amplifier, components perenniality). In this paper, we introduce a completely new design, that makes use of a recent technology, including full linear input electronics, and advanced digital signal processing. As far as the sensor is concerned, both a well known commercial fission chamber, or an innovative wide range sensor presenting a high sensitivity may be used. The basic concept is that the single signal is continuously processed by three different electronic stages, each one being dedicated to approximately one third of the full range: pulse, Campbelling and current modes. After amplification, appropriate shaping, this signal is numerically filtered by a Kalman filter algorithm to compute the neutron flux as well as the reactor period. A specifically developed test module allows the surveillance of the sensor and the electronics via stimuli injections and characteristic curves plotting. A computerised simulation of the whole chain is used to validate the signal processing algorithms evolutions. In the paper we will specifically develop the metrological performances of this chain and the general agreement that exists between simulated and measured values. (authors)

  19. Imaging of extradural spinal lesions

    International Nuclear Information System (INIS)

    Ahlhelm, F.; Schulte-Altedorneburg, G.; Naumann, N.; Reith, W.; Nabhan, A.

    2006-01-01

    There is a wide variety of spinal extradural tumors. In addition to real neoplasms, degenerative diseases, congenital abnormalities and inflammatory disorders can be causes of extradural masses. Due to the bony boundary of the spinal canal, both benign as well as malignant masses can cause progressive neurological deficits including paraplegia. Most of the spinal tumors are benign (hemangioma of the vertebral body, degenerative diseases). In younger patients congenital abnormalities and primary tumors of the spine have to be considered, whereas in adults the list of differential diagnoses should include secondary malignancies such as metastases and lymphomas as well as metabolic disorders such as osteoporotic vertebral compression fracture and Paget's disease. Cross-sectional imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT) of the spine often help to make a specific diagnosis of extradural spinal lesions and represent important tools for tumor staging and preoperative evaluation. (orig.) [de

  20. Note: A wide temperature range MOKE system with annealing capability.

    Science.gov (United States)

    Chahil, Narpinder Singh; Mankey, G J

    2017-07-01

    A novel sample stage integrated with a longitudinal MOKE system has been developed for wide temperature range measurements and annealing capabilities in the temperature range 65 K temperatures without adversely affecting the cryostat and minimizes thermal drift in position. In this system the hysteresis loops of magnetic samples can be measured simultaneously while annealing the sample in a magnetic field.

  1. High dynamic range coding imaging system

    Science.gov (United States)

    Wu, Renfan; Huang, Yifan; Hou, Guangqi

    2014-10-01

    We present a high dynamic range (HDR) imaging system design scheme based on coded aperture technique. This scheme can help us obtain HDR images which have extended depth of field. We adopt Sparse coding algorithm to design coded patterns. Then we utilize the sensor unit to acquire coded images under different exposure settings. With the guide of the multiple exposure parameters, a series of low dynamic range (LDR) coded images are reconstructed. We use some existing algorithms to fuse and display a HDR image by those LDR images. We build an optical simulation model and get some simulation images to verify the novel system.

  2. Respiration and the watershed of spinal CSF flow in humans.

    Science.gov (United States)

    Dreha-Kulaczewski, Steffi; Konopka, Mareen; Joseph, Arun A; Kollmeier, Jost; Merboldt, Klaus-Dietmar; Ludwig, Hans-Christoph; Gärtner, Jutta; Frahm, Jens

    2018-04-04

    The dynamics of human CSF in brain and upper spinal canal are regulated by inspiration and connected to the venous system through associated pressure changes. Upward CSF flow into the head during inspiration counterbalances venous flow out of the brain. Here, we investigated CSF motion along the spinal canal by real-time phase-contrast flow MRI at high spatial and temporal resolution. Results reveal a watershed of spinal CSF dynamics which divides flow behavior at about the level of the heart. While forced inspiration prompts upward surge of CSF flow volumes in the entire spinal canal, ensuing expiration leads to pronounced downward CSF flow, but only in the lower canal. The resulting pattern of net flow volumes during forced respiration yields upward CSF motion in the upper and downward flow in the lower spinal canal. These observations most likely reflect closely coupled CSF and venous systems as both large caval veins and their anastomosing vertebral plexus react to respiration-induced pressure changes.

  3. Extension of photomultiplier tube dynamic range for the LHAASO-KM2A electromagnetic particle detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Hongkui, E-mail: lvhk@ihep.ac.cn [Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); University of Chinese Academy of Sciences, Beijing 100049 (China); Sheng, Xiangdong; He, Huihai; Liu, Jia [Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Zhang, Zhongquan [Shandong University, Jinan 250100 (China); Hou, Chao; Zhao, Jing [Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2015-05-01

    In the Large High Altitude Air Shower Observatory (LHAASO), the 1 km{sup 2} array (KM2A) requires linear measurement of optical intensity with a wide dynamic range. Over 5000 photomultiplier tubes (PMTs) are employed in this experiment and developed as “two outputs” device (anode and dynode) to meet the relevant requirements. In this study, the linearity of the anode and the eighth dynode (DY8), which is limited by space charge effects and mainly related to the relative dynode voltage ratios of the PMT divider, is examined. A voltage divider for the Hamamatsu R11102 PMT is designed and a dramatically enhanced linearity is demonstrated. Test results show that this design can cover a wide dynamic range from 20 to 2×10{sup 5} photoelectrons and achieve a peak anode current of 380 mA at a PMT gain of 10{sup 5}, which satisfies the requirements of KM2A electromagnetic particle detectors. The circuit design has been successfully simulated using the simulation software Multisim. The details of PMT performance tests and simulations are described.

  4. Extension of photomultiplier tube dynamic range for the LHAASO-KM2A electromagnetic particle detectors

    Science.gov (United States)

    Lv, Hongkui; Sheng, Xiangdong; He, Huihai; Liu, Jia; Zhang, Zhongquan; Hou, Chao; Zhao, Jing

    2015-05-01

    In the Large High Altitude Air Shower Observatory (LHAASO), the 1 km2 array (KM2A) requires linear measurement of optical intensity with a wide dynamic range. Over 5000 photomultiplier tubes (PMTs) are employed in this experiment and developed as "two outputs" device (anode and dynode) to meet the relevant requirements. In this study, the linearity of the anode and the eighth dynode (DY8), which is limited by space charge effects and mainly related to the relative dynode voltage ratios of the PMT divider, is examined. A voltage divider for the Hamamatsu R11102 PMT is designed and a dramatically enhanced linearity is demonstrated. Test results show that this design can cover a wide dynamic range from 20 to 2×105 photoelectrons and achieve a peak anode current of 380 mA at a PMT gain of 105, which satisfies the requirements of KM2A electromagnetic particle detectors. The circuit design has been successfully simulated using the simulation software Multisim. The details of PMT performance tests and simulations are described.

  5. Extension of photomultiplier tube dynamic range for the LHAASO-KM2A electromagnetic particle detectors

    International Nuclear Information System (INIS)

    Lv, Hongkui; Sheng, Xiangdong; He, Huihai; Liu, Jia; Zhang, Zhongquan; Hou, Chao; Zhao, Jing

    2015-01-01

    In the Large High Altitude Air Shower Observatory (LHAASO), the 1 km 2 array (KM2A) requires linear measurement of optical intensity with a wide dynamic range. Over 5000 photomultiplier tubes (PMTs) are employed in this experiment and developed as “two outputs” device (anode and dynode) to meet the relevant requirements. In this study, the linearity of the anode and the eighth dynode (DY8), which is limited by space charge effects and mainly related to the relative dynode voltage ratios of the PMT divider, is examined. A voltage divider for the Hamamatsu R11102 PMT is designed and a dramatically enhanced linearity is demonstrated. Test results show that this design can cover a wide dynamic range from 20 to 2×10 5 photoelectrons and achieve a peak anode current of 380 mA at a PMT gain of 10 5 , which satisfies the requirements of KM2A electromagnetic particle detectors. The circuit design has been successfully simulated using the simulation software Multisim. The details of PMT performance tests and simulations are described

  6. RADIANCE DOMAIN COMPOSITING FOR HIGH DYNAMIC RANGE IMAGING

    Directory of Open Access Journals (Sweden)

    M.R. Renu

    2013-02-01

    Full Text Available High dynamic range imaging aims at creating an image with a range of intensity variations larger than the range supported by a camera sensor. Most commonly used methods combine multiple exposure low dynamic range (LDR images, to obtain the high dynamic range (HDR image. Available methods typically neglect the noise term while finding appropriate weighting functions to estimate the camera response function as well as the radiance map. We look at the HDR imaging problem in a denoising frame work and aim at reconstructing a low noise radiance map from noisy low dynamic range images, which is tone mapped to get the LDR equivalent of the HDR image. We propose a maximum aposteriori probability (MAP based reconstruction of the HDR image using Gibb’s prior to model the radiance map, with total variation (TV as the prior to avoid unnecessary smoothing of the radiance field. To make the computation with TV prior efficient, we extend the majorize-minimize method of upper bounding the total variation by a quadratic function to our case which has a nonlinear term arising from the camera response function. A theoretical justification for doing radiance domain denoising as opposed to image domain denoising is also provided.

  7. Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

    International Nuclear Information System (INIS)

    Abernathy, D. L.; Stone, M. B.; Loguillo, M. J.; Lucas, M. S.; Delaire, O.; Tang, X.; Lin, J. Y. Y.; Fultz, B.

    2012-01-01

    The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of 3 He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

  8. Effects of dynamic-range compression on temporal acuity

    DEFF Research Database (Denmark)

    Wiinberg, Alan; Jepsen, Morten Løve; Epp, Bastian

    2016-01-01

    Some of the challenges that hearing-aid listeners experience with speech perception in complex acoustic environments may originate from limitations in the temporal processing of sounds. To systematically investigate the influence of hearing impairment and hearing-aid signal processing on temporal...... processing, temporal modulation transfer functions (TMTFs) and “supra-threshold” modulation-depth discrimination (MDD) thresholds were obtained in normal-hearing (NH) and hearing-impaired (HI) listeners with and without wide-dynamic range compression (WDRC). The TMTFs were obtained using tonal carriers of 1...... with the physical compression of the modulation depth due to the WDRC. Indications of reduced temporal resolution in the HI listeners were observed in the TMTF patterns for the 5 kHz carrier. Significantly higher MDD thresholds were found for the HI group relative to the NH group. No relationship was found between...

  9. Wide-Range Probing of Dzyaloshinskii-Moriya Interaction

    Science.gov (United States)

    Kim, Duck-Ho; Yoo, Sang-Cheol; Kim, Dae-Yun; Min, Byoung-Chul; Choe, Sug-Bong

    2017-03-01

    The Dzyaloshinskii-Moriya interaction (DMI) in magnetic objects is of enormous interest, because it generates built-in chirality of magnetic domain walls (DWs) and topologically protected skyrmions, leading to efficient motion driven by spin-orbit torques. Because of its importance for both potential applications and fundamental research, many experimental efforts have been devoted to DMI investigation. However, current experimental probing techniques cover only limited ranges of the DMI strength and have specific sample requirements. Thus, there are no versatile methods to quantify DMI over a wide range of values. Here, we present such an experimental scheme, which is based on the angular dependence of asymmetric DW motion. This method can be used to determine values of DMI much larger than the maximum strength of the external magnetic field strength, which demonstrates that various DMI strengths can be quantified with a single measurement setup. This scheme may thus prove essential to DMI-related emerging fields in nanotechnology.

  10. Climate driven range divergence among host species affects range-wide patterns of parasitism

    Directory of Open Access Journals (Sweden)

    Richard E. Feldman

    2017-01-01

    Full Text Available Species interactions like parasitism influence the outcome of climate-driven shifts in species ranges. For some host species, parasitism can only occur in that part of its range that overlaps with a second host species. Thus, predicting future parasitism may depend on how the ranges of the two hosts change in relation to each other. In this study, we tested whether the climate driven species range shift of Odocoileus virginianus (white-tailed deer accounts for predicted changes in parasitism of two other species from the family Cervidae, Alces alces (moose and Rangifer tarandus (caribou, in North America. We used MaxEnt models to predict the recent (2000 and future (2050 ranges (probabilities of occurrence of the cervids and a parasite Parelaphostrongylus tenuis (brainworm taking into account range shifts of the parasite’s intermediate gastropod hosts. Our models predicted that range overlap between A. alces/R. tarandus and P. tenuis will decrease between 2000 and 2050, an outcome that reflects decreased overlap between A. alces/R. tarandus and O. virginianus and not the parasites, themselves. Geographically, our models predicted increasing potential occurrence of P. tenuis where A. alces/R. tarandus are likely to decline, but minimal spatial overlap where A. alces/R. tarandus are likely to increase. Thus, parasitism may exacerbate climate-mediated southern contraction of A. alces and R. tarandus ranges but will have limited influence on northward range expansion. Our results suggest that the spatial dynamics of one host species may be the driving force behind future rates of parasitism for another host species.

  11. High Dynamic Range Imaging Using Multiple Exposures

    Science.gov (United States)

    Hou, Xinglin; Luo, Haibo; Zhou, Peipei; Zhou, Wei

    2017-06-01

    It is challenging to capture a high-dynamic range (HDR) scene using a low-dynamic range (LDR) camera. This paper presents an approach for improving the dynamic range of cameras by using multiple exposure images of same scene taken under different exposure times. First, the camera response function (CRF) is recovered by solving a high-order polynomial in which only the ratios of the exposures are used. Then, the HDR radiance image is reconstructed by weighted summation of the each radiance maps. After that, a novel local tone mapping (TM) operator is proposed for the display of the HDR radiance image. By solving the high-order polynomial, the CRF can be recovered quickly and easily. Taken the local image feature and characteristic of histogram statics into consideration, the proposed TM operator could preserve the local details efficiently. Experimental result demonstrates the effectiveness of our method. By comparison, the method outperforms other methods in terms of imaging quality.

  12. Tribological behavior and self-healing functionality of TiNbCN-Ag coatings in wide temperature range

    Energy Technology Data Exchange (ETDEWEB)

    Bondarev, A.V., E-mail: abondarev88@gmail.com; Kiryukhantsev-Korneev, Ph.V.; Levashov, E.A.; Shtansky, D.V., E-mail: shtansky@shs.misis.ru

    2017-02-28

    Highlights: • TiNbCN–Ag coatings for wide temperature range tribological applications. • Alloying with Nb and Ag improve tribological properties and oxidation resistance. • Ag-rich TiNbCN coatings show friction coefficient below 0.45 in range of 25–700 °C. • Ag-doped coatings show active oxidation protection and self-healing functionality. - Abstract: Ag- and Nb-doped TiCN coatings with about 2 at.% of Nb and Ag contents varied between 4.0 and 15.1 at.% were designed as promising materials for tribological applications in a wide temperature range. We report on the structure, mechanical, and tribological properties of TiNbCN-Ag coatings fabricated by simultaneous co-sputtering of TiC{sub 0.5} + 10%Nb{sub 2}C and Ag targets in comparison with those of Ag-free coating. The tribological characteristics were evaluated during constant-temperature tests both at room temperature and 300 °C, as well as during dynamic temperature ramp tests in the range of 25–700 °C. The coating structure and elemental composition were studied by means of X-ray diffraction, scanning and transmission electron microscopy, and glow discharge optical emission spectroscopy. The coating microstructures and elemental compositions inside wear tracks, as well as the wear products, were examined by scanning electron microscopy, energy-dispersive spectroscopy, and Raman spectroscopy. We demonstrate that simultaneous alloying with Nb and Ag permits to overcome the main drawbacks of TiCN coatings such as their relatively high values of friction coefficient at elevated temperatures and low oxidation resistance. It is shown that a relatively high amount of Ag (15 at.%) is required to provide enhanced tribological behavior in a wide temperature range of 25–700 °C. In addition, the prepared Ag-doped coatings demonstrated active oxidation protection and self-healing functionality due to the segregation of Ag metallic particles in damage areas such as cracks, pin-holes, or oxidation sites.

  13. Effects of core instability strength training on trunk muscle strength, spinal mobility, dynamic balance and functional mobility in older adults.

    Science.gov (United States)

    Granacher, Urs; Lacroix, Andre; Muehlbauer, Thomas; Roettger, Katrin; Gollhofer, Albert

    2013-01-01

    Age-related postural misalignment, balance deficits and strength/power losses are associated with impaired functional mobility and an increased risk of falling in seniors. Core instability strength training (CIT) involves exercises that are challenging for both trunk muscles and postural control and may thus have the potential to induce benefits in trunk muscle strength, spinal mobility and balance performance. The objective was to investigate the effects of CIT on measures of trunk muscle strength, spinal mobility, dynamic balance and functional mobility in seniors. Thirty-two older adults were randomly assigned to an intervention group (INT; n = 16, aged 70.8 ± 4.1 years) that conducted a 9-week progressive CIT or to a control group (n = 16, aged 70.2 ± 4.5 years). Maximal isometric strength of the trunk flexors/extensors/lateral flexors (right, left)/rotators (right, left) as well as of spinal mobility in the sagittal and the coronal plane was measured before and after the intervention program. Dynamic balance (i.e. walking 10 m on an optoelectric walkway, the Functional Reach test) and functional mobility (Timed Up and Go test) were additionally tested. Program compliance was excellent with participants of the INT group completing 92% of the training sessions. Significant group × test interactions were found for the maximal isometric strength of the trunk flexors (34%, p training-related improvements were found for spinal mobility in the sagittal (11%, p velocity (9%, p velocity (31%, p training regimen could be used as an adjunct or even alternative to traditional balance and/or resistance training. Copyright © 2012 S. Karger AG, Basel.

  14. Maladaptive spinal plasticity opposes spinal learning and recovery in spinal cord injury

    Directory of Open Access Journals (Sweden)

    Adam R Ferguson

    2012-10-01

    Full Text Available Synaptic plasticity within the spinal cord has great potential to facilitate recovery of function after spinal cord injury (SCI. Spinal plasticity can be induced in an activity-dependent manner even without input from the brain after complete SCI. The mechanistic basis for these effects is provided by research demonstrating that spinal synapses have many of the same plasticity mechanisms that are known to underlie learning and memory in the brain. In addition, the lumbar spinal cord can sustain several forms of learning and memory, including limb-position training. However, not all spinal plasticity promotes recovery of function. Central sensitization of nociceptive (pain pathways in the spinal cord may emerge with certain patterns of activity, demonstrating that plasticity within the spinal cord may contribute to maladaptive pain states. In this review we discuss interactions between adaptive and maladaptive forms of activity-dependent plasticity in the spinal cord. The literature demonstrates that activity-dependent plasticity within the spinal cord must be carefully tuned to promote adaptive spinal training. Stimulation that is delivered in a limb position-dependent manner or on a fixed interval can induce adaptive plasticity that promotes future spinal cord learning and reduces nociceptive hyper-reactivity. On the other hand, stimulation that is delivered in an unsynchronized fashion, such as randomized electrical stimulation or peripheral skin injuries, can generate maladaptive spinal plasticity that undermines future spinal cord learning, reduces recovery of locomotor function, and promotes nociceptive hyper-reactivity after spinal cord injury. We review these basic phenomena, discuss the cellular and molecular mechanisms, and discuss implications of these findings for improved rehabilitative therapies after spinal cord injury.

  15. Wide Range Portable Radiation Survey Meter for Emergency Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gangadharan, P.; Bhave, D. G.; Gokarn, R. S.; Khadake, R. G. [Directorate Of Radiation Protection, Bhabha Atomic Research Centre, Trombay, Bombay (India)

    1969-05-15

    The paper describes a portable battery-operated radiation survey meter for monitoring a wide range of X- and gamma-ray exposure rates from 1 mR/h to 100 R/h. The instrument Incorporates a halogen GM tube as the detector and a count-rate meter for indication. A transistorized d.c. -d.c. converter supplies the necessary high voltage to the GM counter. The instrument response has been made energy independent in the energy range 80 keV to 1.25 MeV. Further, the response is linear over the entire range of exposure rates. Suitable extension rods have been designed to provide sufficient separation between the probe and the meter in cases where remote monitoring is necessary because of high fields. (author)

  16. Benchmarking novel approaches for modelling species range dynamics.

    Science.gov (United States)

    Zurell, Damaris; Thuiller, Wilfried; Pagel, Jörn; Cabral, Juliano S; Münkemüller, Tamara; Gravel, Dominique; Dullinger, Stefan; Normand, Signe; Schiffers, Katja H; Moore, Kara A; Zimmermann, Niklaus E

    2016-08-01

    Increasing biodiversity loss due to climate change is one of the most vital challenges of the 21st century. To anticipate and mitigate biodiversity loss, models are needed that reliably project species' range dynamics and extinction risks. Recently, several new approaches to model range dynamics have been developed to supplement correlative species distribution models (SDMs), but applications clearly lag behind model development. Indeed, no comparative analysis has been performed to evaluate their performance. Here, we build on process-based, simulated data for benchmarking five range (dynamic) models of varying complexity including classical SDMs, SDMs coupled with simple dispersal or more complex population dynamic models (SDM hybrids), and a hierarchical Bayesian process-based dynamic range model (DRM). We specifically test the effects of demographic and community processes on model predictive performance. Under current climate, DRMs performed best, although only marginally. Under climate change, predictive performance varied considerably, with no clear winners. Yet, all range dynamic models improved predictions under climate change substantially compared to purely correlative SDMs, and the population dynamic models also predicted reasonable extinction risks for most scenarios. When benchmarking data were simulated with more complex demographic and community processes, simple SDM hybrids including only dispersal often proved most reliable. Finally, we found that structural decisions during model building can have great impact on model accuracy, but prior system knowledge on important processes can reduce these uncertainties considerably. Our results reassure the clear merit in using dynamic approaches for modelling species' response to climate change but also emphasize several needs for further model and data improvement. We propose and discuss perspectives for improving range projections through combination of multiple models and for making these approaches

  17. Reconstructing Interlaced High-Dynamic-Range Video Using Joint Learning.

    Science.gov (United States)

    Inchang Choi; Seung-Hwan Baek; Kim, Min H

    2017-11-01

    For extending the dynamic range of video, it is a common practice to capture multiple frames sequentially with different exposures and combine them to extend the dynamic range of each video frame. However, this approach results in typical ghosting artifacts due to fast and complex motion in nature. As an alternative, video imaging with interlaced exposures has been introduced to extend the dynamic range. However, the interlaced approach has been hindered by jaggy artifacts and sensor noise, leading to concerns over image quality. In this paper, we propose a data-driven approach for jointly solving two specific problems of deinterlacing and denoising that arise in interlaced video imaging with different exposures. First, we solve the deinterlacing problem using joint dictionary learning via sparse coding. Since partial information of detail in differently exposed rows is often available via interlacing, we make use of the information to reconstruct details of the extended dynamic range from the interlaced video input. Second, we jointly solve the denoising problem by tailoring sparse coding to better handle additive noise in low-/high-exposure rows, and also adopt multiscale homography flow to temporal sequences for denoising. We anticipate that the proposed method will allow for concurrent capture of higher dynamic range video frames without suffering from ghosting artifacts. We demonstrate the advantages of our interlaced video imaging compared with the state-of-the-art high-dynamic-range video methods.

  18. A design of an on-orbit radiometric calibration device for high dynamic range infrared remote sensors

    Science.gov (United States)

    Sheng, Yicheng; Jin, Weiqi; Dun, Xiong; Zhou, Feng; Xiao, Si

    2017-10-01

    With the demand of quantitative remote sensing technology growing, high reliability as well as high accuracy radiometric calibration technology, especially the on-orbit radiometric calibration device has become an essential orientation in term of quantitative remote sensing technology. In recent years, global launches of remote sensing satellites are equipped with innovative on-orbit radiometric calibration devices. In order to meet the requirements of covering a very wide dynamic range and no-shielding radiometric calibration system, we designed a projection-type radiometric calibration device for high dynamic range sensors based on the Schmidt telescope system. In this internal radiometric calibration device, we select the EF-8530 light source as the calibration blackbody. EF-8530 is a high emittance Nichrome (Ni-Cr) reference source. It can operate in steady or pulsed state mode at a peak temperature of 973K. The irradiance from the source was projected to the IRFPA. The irradiance needs to ensure that the IRFPA can obtain different amplitude of the uniform irradiance through the narrow IR passbands and cover the very wide dynamic range. Combining the internal on-orbit radiometric calibration device with the specially designed adaptive radiometric calibration algorithms, an on-orbit dynamic non-uniformity correction can be accomplished without blocking the optical beam from outside the telescope. The design optimizes optics, source design, and power supply electronics for irradiance accuracy and uniformity. The internal on-orbit radiometric calibration device not only satisfies a series of indexes such as stability, accuracy, large dynamic range and uniformity of irradiance, but also has the advantages of short heating and cooling time, small volume, lightweight, low power consumption and many other features. It can realize the fast and efficient relative radiometric calibration without shielding the field of view. The device can applied to the design and

  19. Wide range optofluidically tunable multimode interference fiber laser

    International Nuclear Information System (INIS)

    Antonio-Lopez, J E; LiKamWa, P; Sanchez-Mondragon, J J; May-Arrioja, D A

    2014-01-01

    An optofluidically tunable fiber laser based on multimode interference (MMI) effects with a wide tuning range is proposed and demonstrated. The tunable mechanism is based on an MMI fiber filter fabricated using a special fiber known as no-core fiber, which is a multimode fiber (MMF) without cladding. Therefore, when the MMI filter is covered by liquid the optical properties of the no-core fiber are modified, which allow us to tune the peak wavelength response of the MMI filter. Rather than applying the liquid on the entire no-core fiber, we change the liquid level along the no-core fiber, which provides a highly linear tuning response. In addition, by selecting the adequate refractive index of the liquid we can also choose the tuning range. We demonstrate the versatility of the optofluidically tunable MMI filter by wavelength tuning two different gain media, erbium doped fiber and a semiconductor optical amplifier, achieving tuning ranges of 55 and 90 nm respectively. In both cases, we achieve side-mode suppression ratios (SMSR) better than 50 dBm with output power variations of less than 0.76 dBm over the whole tuning range. (paper)

  20. Defining spinal instability and methods of classification to optimise care for patients with malignant spinal cord compression: A systematic review

    International Nuclear Information System (INIS)

    Sheehan, C.

    2016-01-01

    The incidence of Malignant Spinal Cord Compression (MSCC) is thought to be increasing in the UK due to an aging population and improving cancer survivorship. The impact of such a diagnosis requires emergency treatment. In 2008 the National Institute of Clinical Excellence produced guidelines on the management of MSCC which includes a recommendation to assess spinal instability. However, a lack of guidelines to assess spinal instability in oncology patients is widely acknowledged. This can result in variations in the management of care for such patients. A spinal instability assessment can influence optimum patient care (bed rest or encouraged mobilisation) and inform the best definitive treatment modality (surgery or radiotherapy) for an individual patient. The aim of this systematic review is to attempt to identify a consensus definition of spinal instability and methods by which it can be classified. - Highlights: • A lack of guidance on metastatic spinal instability results in variations of care. • Definitions and assessments for spinal instability are explored in this review. • A Spinal Instability Neoplastic Scoring (SINS) system has been identified. • SINS could potentially be adopted to optimise and standardise patient care.

  1. Wide Range Vacuum Pumps for the SAM Instrument on the MSL Curiosity Rover

    Science.gov (United States)

    Sorensen, Paul; Kline-Schoder, Robert; Farley, Rodger

    2014-01-01

    Creare Incorporated and NASA Goddard Space Flight Center developed and space qualified two wide range pumps (WRPs) that were included in the Sample Analysis at Mars (SAM) instrument. This instrument was subsequently integrated into the Mars Science Laboratory (MSL) "Curiosity Rover," launched aboard an Atlas V rocket in 2011, and landed on August 6, 2012, in the Gale Crater on Mars. The pumps have now operated for more than 18 months in the Gale Crater and have been evacuating the key components of the SAM instrument: a quadrupole mass spectrometer, a tunable laser spectrometer, and six gas chromatograph columns. In this paper, we describe the main design challenges and the ways in which they were solved. This includes the custom design of a miniaturized, high-speed motor to drive the turbo drag pump rotor, analysis of rotor dynamics for super critical operation, and bearing/lubricant design/selection.

  2. Polymer Nanoparticle-Based Chemotherapy for Spinal Malignancies

    Directory of Open Access Journals (Sweden)

    Hongyun Ma

    2016-01-01

    Full Text Available Malignant spinal tumors, categorized into primary and metastatic ones, are one of the most serious diseases due to their high morbidity and mortality rates. Common primary spinal tumors include chordoma, chondrosarcoma, osteosarcoma, Ewing’s sarcoma, and multiple myeloma. Spinal malignancies are not only locally invasive and destructive to adjacent structures, such as bone, neural, and vascular structures, but also disruptive to distant organs (e.g., lung. Current treatments for spinal malignancies, including wide resection, radiotherapy, and chemotherapy, have made significant progress like improving patients’ quality of life. Among them, chemotherapy plays an important role, but its potential for clinical application is limited by severe side effects and drug resistance. To ameliorate the current situation, various polymer nanoparticles have been developed as promising excipients to facilitate the effective treatment of spinal malignancies by utilizing their potent advantages, for example, targeting, stimuli response, and synergetic effect. This review overviews the development of polymer nanoparticles for antineoplastic delivery in the treatment of spinal malignancies and discusses future prospects of polymer nanoparticle-based treatment methods.

  3. MRI findings on iatrogenic spinal infection following various pain management procedures

    International Nuclear Information System (INIS)

    Kim, Yu Jin; Lee, Jee Young; Kim, Bong Man; Min, Sang Hyuk

    2014-01-01

    The aim of this study was to investigate and report magnetic resonance imaging (MRI) findings of iatrogenic spinal infection (ISI). We retrospectively reviewed the clinical and MRI findings on 18 patients diagnosed with ISI. The MRI findings were evaluated for the number of spinal segments showing inflammation in the longitudinal span and affected vertebral bodies and discs, the presence of abscess in the epidural or paravertebral space, paravertebral myositis, and skip lesions. Among the 18 patients, the range of the longitudinal span of spinal inflammation was 2-11 (mean = 5.84) vertebral segments. 17 of the 18 patients had three or more contiguous vertebral segments. The osteomyelitis and disc destruction was apparent in 77.8% and 66.7% of the patients, and 78% of patients with osteomyelitis showed involvement of one or two vertebrae; 91.7% of patients with disc destruction showed involvement of single disc. The incidence of epidural or paravertebral abscesses, and paravertebral myositis were 88.9%, and 94.4%. There were no spinal skip lesions. MRI findings of those are wide longitudinal span of infection, involvement of no more than one or two vertebral bodies and a single disc, large abscesses, extensive myositis and no skip lesions, can be a useful ISI-diagnostic tool.

  4. MRI findings on iatrogenic spinal infection following various pain management procedures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yu Jin; Lee, Jee Young; Kim, Bong Man [Dept. of Radiology, Dankook University Hospital, Cheonan (Korea, Republic of); Min, Sang Hyuk [Dept. of Orthopedic Surgery, Dankook University Hospital, Cheonan (Korea, Republic of)

    2014-12-15

    The aim of this study was to investigate and report magnetic resonance imaging (MRI) findings of iatrogenic spinal infection (ISI). We retrospectively reviewed the clinical and MRI findings on 18 patients diagnosed with ISI. The MRI findings were evaluated for the number of spinal segments showing inflammation in the longitudinal span and affected vertebral bodies and discs, the presence of abscess in the epidural or paravertebral space, paravertebral myositis, and skip lesions. Among the 18 patients, the range of the longitudinal span of spinal inflammation was 2-11 (mean = 5.84) vertebral segments. 17 of the 18 patients had three or more contiguous vertebral segments. The osteomyelitis and disc destruction was apparent in 77.8% and 66.7% of the patients, and 78% of patients with osteomyelitis showed involvement of one or two vertebrae; 91.7% of patients with disc destruction showed involvement of single disc. The incidence of epidural or paravertebral abscesses, and paravertebral myositis were 88.9%, and 94.4%. There were no spinal skip lesions. MRI findings of those are wide longitudinal span of infection, involvement of no more than one or two vertebral bodies and a single disc, large abscesses, extensive myositis and no skip lesions, can be a useful ISI-diagnostic tool.

  5. Real-time high dynamic range laser scanning microscopy

    Science.gov (United States)

    Vinegoni, C.; Leon Swisher, C.; Fumene Feruglio, P.; Giedt, R. J.; Rousso, D. L.; Stapleton, S.; Weissleder, R.

    2016-04-01

    In conventional confocal/multiphoton fluorescence microscopy, images are typically acquired under ideal settings and after extensive optimization of parameters for a given structure or feature, often resulting in information loss from other image attributes. To overcome the problem of selective data display, we developed a new method that extends the imaging dynamic range in optical microscopy and improves the signal-to-noise ratio. Here we demonstrate how real-time and sequential high dynamic range microscopy facilitates automated three-dimensional neural segmentation. We address reconstruction and segmentation performance on samples with different size, anatomy and complexity. Finally, in vivo real-time high dynamic range imaging is also demonstrated, making the technique particularly relevant for longitudinal imaging in the presence of physiological motion and/or for quantification of in vivo fast tracer kinetics during functional imaging.

  6. Maladaptive spinal plasticity opposes spinal learning and recovery in spinal cord injury

    Science.gov (United States)

    Ferguson, Adam R.; Huie, J. Russell; Crown, Eric D.; Baumbauer, Kyle M.; Hook, Michelle A.; Garraway, Sandra M.; Lee, Kuan H.; Hoy, Kevin C.; Grau, James W.

    2012-01-01

    Synaptic plasticity within the spinal cord has great potential to facilitate recovery of function after spinal cord injury (SCI). Spinal plasticity can be induced in an activity-dependent manner even without input from the brain after complete SCI. A mechanistic basis for these effects is provided by research demonstrating that spinal synapses have many of the same plasticity mechanisms that are known to underlie learning and memory in the brain. In addition, the lumbar spinal cord can sustain several forms of learning and memory, including limb-position training. However, not all spinal plasticity promotes recovery of function. Central sensitization of nociceptive (pain) pathways in the spinal cord may emerge in response to various noxious inputs, demonstrating that plasticity within the spinal cord may contribute to maladaptive pain states. In this review we discuss interactions between adaptive and maladaptive forms of activity-dependent plasticity in the spinal cord below the level of SCI. The literature demonstrates that activity-dependent plasticity within the spinal cord must be carefully tuned to promote adaptive spinal training. Prior work from our group has shown that stimulation that is delivered in a limb position-dependent manner or on a fixed interval can induce adaptive plasticity that promotes future spinal cord learning and reduces nociceptive hyper-reactivity. On the other hand, stimulation that is delivered in an unsynchronized fashion, such as randomized electrical stimulation or peripheral skin injuries, can generate maladaptive spinal plasticity that undermines future spinal cord learning, reduces recovery of locomotor function, and promotes nociceptive hyper-reactivity after SCI. We review these basic phenomena, how these findings relate to the broader spinal plasticity literature, discuss the cellular and molecular mechanisms, and finally discuss implications of these and other findings for improved rehabilitative therapies after SCI. PMID

  7. Dynamic Planar Range Maxima Queries

    DEFF Research Database (Denmark)

    Brodal, Gerth Stølting; Tsakalidis, Konstantinos

    2011-01-01

    We consider the dynamic two-dimensional maxima query problem. Let P be a set of n points in the plane. A point is maximal if it is not dominated by any other point in P. We describe two data structures that support the reporting of the t maximal points that dominate a given query point, and allow...... for insertions and deletions of points in P. In the pointer machine model we present a linear space data structure with O(logn + t) worst case query time and O(logn) worst case update time. This is the first dynamic data structure for the planar maxima dominance query problem that achieves these bounds...... are integers in the range U = {0, …,2 w  − 1 }. We present a linear space data structure that supports 3-sided range maxima queries in O(logn/loglogn+t) worst case time and updates in O(logn/loglogn) worst case time. These are the first sublogarithmic worst case bounds for all operations in the RAM model....

  8. Development of a wide-range tritium-concentration detector

    International Nuclear Information System (INIS)

    Jun, F.; Zhe, L.; Shicheng, L.; Jiangfeng, S.; Deli, L.

    2015-01-01

    According to the requirements of the tritium related systems of the TBM (Test Blanket Module) for monitoring the on-line tritium concentration, a wide-range tritium-concentration detector has been developed to measure the tritium concentration in the range of 10 4 Bq/ml - 5*10 8 Bq/ml. This detector is combined with a low-memory helium ionization chamber. The weak current signal collected in the ionization chamber is converted to the voltage signal by an I-V converter. The minimum weak current which the detector could be measured is 10 -14 A. The performance of the background current and the current response linearity of the prototype have been tested. The test result indicates that the linear response of the current signal of the prototype without connecting the ionization chamber is good. The linear correlation coefficient is R 2 = 0.998

  9. A Wide Lock-Range Referenceless CDR with Automatic Frequency Acquisition

    OpenAIRE

    Seon-Kyoo Lee; Young-Sang Kim; Hong-June Park; Jae-Yoon Sim

    2011-01-01

    A wide lock-range referenceless CDR circuit is proposed with an automatic tracking of data rate. For efficient frequency acquisition, a DLL-based loop is used with a simple phase/frequency detector to extract 1-bit period of input data stream. The CDR, implemented in a 65 nm CMOS, shows a lock range of 650 Mb/s-to-8 Gb/s and BER of less than 10-12 at 8 Gb/s with low power consumption.

  10. A Wide Lock-Range Referenceless CDR with Automatic Frequency Acquisition

    Directory of Open Access Journals (Sweden)

    Seon-Kyoo Lee

    2011-01-01

    Full Text Available A wide lock-range referenceless CDR circuit is proposed with an automatic tracking of data rate. For efficient frequency acquisition, a DLL-based loop is used with a simple phase/frequency detector to extract 1-bit period of input data stream. The CDR, implemented in a 65 nm CMOS, shows a lock range of 650 Mb/s-to-8 Gb/s and BER of less than 10-12 at 8 Gb/s with low power consumption.

  11. Wide Operating Voltage Range Fuel Cell Battery Charger

    DEFF Research Database (Denmark)

    Hernandez Botella, Juan Carlos; Mira Albert, Maria del Carmen; Sen, Gokhan

    2014-01-01

    DC-DC converters for fuel cell applications require wide voltage range operation due to the unique fuel cell characteristic curve. Primary parallel isolated boost converter (PPIBC) is a boost derived topology for low voltage high current applications reaching an efficiency figure up to 98...... by two the converter input-to-output voltage gain. This allows covering the conditions when the fuel cell stack operates in the activation region (maximum output voltage) and increases the degrees of freedom for converter optimization. The transition between operating modes is studied because represents...

  12. Spinal endoscopy combined with selective CT myelography for dural closure of the spinal dural defect with superficial siderosis: technical note.

    Science.gov (United States)

    Arishima, Hidetaka; Higashino, Yoshifumi; Yamada, Shinsuke; Akazawa, Ayumi; Arai, Hiroshi; Tsunetoshi, Kenzo; Matsuda, Ken; Kodera, Toshiaki; Kitai, Ryuhei; Awara, Kousuke; Kikuta, Ken-Ichiro

    2018-01-01

    The authors describe a new procedure to detect the tiny dural hole in patients with superficial siderosis (SS) and CSF leakage using a coronary angioscope system for spinal endoscopy and selective CT myelography using a spinal drainage tube. Under fluoroscopy, surgeons inserted the coronary angioscope into the spinal subarachnoid space, similar to the procedure of spinal drainage, and slowly advanced it to the cervical spine. The angioscope clearly showed the small dural hole and injured arachnoid membrane. One week later, the spinal drainage tube was inserted, and the tip of the drainage tube was located just below the level of the dural defect found by the spinal endoscopic examination. This selective CT myelography clarifies the location of the dural defect. During surgery, the small dural hole could be easily located, and it was securely sutured. It is sometimes difficult to detect the actual location of the small dural hole even with thin-slice MRI or dynamic CT myelography in patients with SS. The use of a coronary angioscope for the spinal endoscopy combined with selective CT myelography may provide an effective examination to assess dural closure of the spinal dural defect with SS in cases without obvious dural defects on conventional imaging.

  13. Focal Anterior Displacement of the Thoracic Spinal Cord without Evidence of Spinal Cord Herniation or an Intradural Mass

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Yoon; Lee, Joon Woo; Lee, Guen Young; Kang, Heung Sik [Department of Radiology, Seoul National University Bundang Hospital, Seongnam 463-707 (Korea, Republic of)

    2014-07-01

    We report magnetic resonance imaging (MRI) findings on focal anterior displacement of the thoracic spinal cord in asymptomatic patients without a spinal cord herniation or intradural mass. We identified 12 patients (male:female = 6:6; mean age, 51.7; range, 15-83 years) between 2007 and 2011, with focal anterior displacement of the spinal cord and without evidence of an intradural mass or spinal cord herniation. Two radiologists retrospectively reviewed the MRI findings in consensus. An asymmetric spinal cord deformity with a focal dented appearance was seen on the posterior surface of the spinal cord in all patients, and it involved a length of 1 or 2 vertebral segments in the upper thoracic spine (thoracic vertebrae 1-6). Moreover, a focal widening of the posterior subarachnoid space was also observed in all cases. None of the patients had myelopathy symptoms, and they showed no focal T2-hyperintensity in the spinal cord with the exception of one patient. In addition, cerebrospinal fluid (CSF) flow artifacts were seen in the posterior subarachnoid space of the affected spinal cord level. Computed tomography myelography revealed preserved CSF flow in the two available patients. Focal anterior spinal cord indentation can be found in the upper thoracic level of asymptomatic patients without a spinal cord herniation or intradural mass.

  14. Focal Anterior Displacement of the Thoracic Spinal Cord without Evidence of Spinal Cord Herniation or an Intradural Mass

    International Nuclear Information System (INIS)

    Lee, Jong Yoon; Lee, Joon Woo; Lee, Guen Young; Kang, Heung Sik

    2014-01-01

    We report magnetic resonance imaging (MRI) findings on focal anterior displacement of the thoracic spinal cord in asymptomatic patients without a spinal cord herniation or intradural mass. We identified 12 patients (male:female = 6:6; mean age, 51.7; range, 15-83 years) between 2007 and 2011, with focal anterior displacement of the spinal cord and without evidence of an intradural mass or spinal cord herniation. Two radiologists retrospectively reviewed the MRI findings in consensus. An asymmetric spinal cord deformity with a focal dented appearance was seen on the posterior surface of the spinal cord in all patients, and it involved a length of 1 or 2 vertebral segments in the upper thoracic spine (thoracic vertebrae 1-6). Moreover, a focal widening of the posterior subarachnoid space was also observed in all cases. None of the patients had myelopathy symptoms, and they showed no focal T2-hyperintensity in the spinal cord with the exception of one patient. In addition, cerebrospinal fluid (CSF) flow artifacts were seen in the posterior subarachnoid space of the affected spinal cord level. Computed tomography myelography revealed preserved CSF flow in the two available patients. Focal anterior spinal cord indentation can be found in the upper thoracic level of asymptomatic patients without a spinal cord herniation or intradural mass

  15. Delayed radiation necrosis of a spinal nerve root presenting as an intra-spinal mass

    International Nuclear Information System (INIS)

    Mikhael, M.A.

    1979-01-01

    Details are given of the case history of a 16 year old male with a six week history of progressive weakness of the arms and legs seven years after his last course of radiotherapy for Hodgkin's disease. Histopathological examination of an excised hard fibrotic mass revealed delayed radiation necrosis of a spinal root nerve with no evidence of Hodgkin's disease. The mass recurred seven months later and was removed by wide excision. The spinal cord had probably received less than 2000 rad during one course of radiotherapy. The 15 MeV electron beam of the second course of radiotherapy would not have penetrated the spinal cord itself, but the nerve roots would have received a much higher dose. Nerve roots should therefore be shielded whenever possible during radiotherapy, and the possibility of radiation necrosis considered in the differential diagnosis of intraspinal masses in the field of earlier radiation therapy. (UK)

  16. Development of a wide-range tritium-concentration detector

    Energy Technology Data Exchange (ETDEWEB)

    Jun, F.; Zhe, L.; Shicheng, L.; Jiangfeng, S.; Deli, L. [China Academy of Engineering Physics, Mianyang (China)

    2015-03-15

    According to the requirements of the tritium related systems of the TBM (Test Blanket Module) for monitoring the on-line tritium concentration, a wide-range tritium-concentration detector has been developed to measure the tritium concentration in the range of 10{sup 4} Bq/ml - 5*10{sup 8} Bq/ml. This detector is combined with a low-memory helium ionization chamber. The weak current signal collected in the ionization chamber is converted to the voltage signal by an I-V converter. The minimum weak current which the detector could be measured is 10{sup -14} A. The performance of the background current and the current response linearity of the prototype have been tested. The test result indicates that the linear response of the current signal of the prototype without connecting the ionization chamber is good. The linear correlation coefficient is R{sup 2} = 0.998.

  17. Spinal deformity in patients with Sotos syndrome (cerebral gigantism).

    Science.gov (United States)

    Tsirikos, Athanasios I; Demosthenous, Nestor; McMaster, Michael J

    2009-04-01

    Retrospective review of a case series. To present the clinical characteristics and progression of spinal deformity in patients with Sotos syndrome. There is limited information on the development of spinal deformity and the need for treatment in this condition. The medical records and spinal radiographs of 5 consecutive patients were reviewed. All patients were followed to skeletal maturity (mean follow-up: 6.6 y). The mean age at diagnosis of spinal deformity was 11.9 years (range: 5.8 to 14.5) with 4 patients presenting in adolescence. The type of deformity was not uniform. Two patients presented in adolescence with relatively small and nonprogressive thoracolumbar and lumbar scoliosis, which required observation but no treatment until the end of spinal growth. Three patients underwent spinal deformity correction at a mean age of 11.7 years (range: 6 to 15.4). The first patient developed a double structural thoracic and lumbar scoliosis and underwent a posterior spinal arthrodesis extending from T3 to L4. Five years later, she developed marked degenerative changes at the L4/L5 level causing symptomatic bilateral lateral recess stenosis and affecting the L5 nerve roots. She underwent spinal decompression at L4/L5 and L5/S1 levels followed by extension of the fusion to the sacrum. The second patient developed a severe thoracic kyphosis and underwent a posterior spinal arthrodesis. The remaining patient presented at the age of 5.9 years with a severe thoracic kyphoscoliosis and underwent a 2-stage antero-posterior spinal arthrodesis. The development of spinal deformity is a common finding in children with Sotos syndrome and in our series it occurred in adolescence in 4 out of 5 patients. There is significant variability on the pattern of spine deformity, ranging from a scoliosis through kyphoscoliosis to a pure kyphosis, and also the age at presentation and need for treatment.

  18. Face recognition based on matching of local features on 3D dynamic range sequences

    Science.gov (United States)

    Echeagaray-Patrón, B. A.; Kober, Vitaly

    2016-09-01

    3D face recognition has attracted attention in the last decade due to improvement of technology of 3D image acquisition and its wide range of applications such as access control, surveillance, human-computer interaction and biometric identification systems. Most research on 3D face recognition has focused on analysis of 3D still data. In this work, a new method for face recognition using dynamic 3D range sequences is proposed. Experimental results are presented and discussed using 3D sequences in the presence of pose variation. The performance of the proposed method is compared with that of conventional face recognition algorithms based on descriptors.

  19. Spinal Cord Stimulation

    DEFF Research Database (Denmark)

    Meier, Kaare

    2014-01-01

    Spinal cord stimulation (SCS) is a surgical treatment for chronic neuropathic pain that is refractory to other treatment. Originally described by Shealy et al. in 1967(1), it is used to treat a range of conditions such as complex regional pain syndrome (CRPS I)(2), angina pectoris(3), radicular...... pain after failed back surgery syndrome (FBSS)(4), pain due to peripheral nerve injury, stump pain(5), peripheral vascular disease(6) and diabetic neuropathy(7,8); whereas phantom pain(9), postherpetic neuralgia(10), chronic visceral pain(11), and pain after partial spinal cord injury(12) remain more...

  20. Magnetic resonance imaging of acute spinal-cord injury

    International Nuclear Information System (INIS)

    Yamamoto, Hideki; Nakagawa, Hiroshi; Yamada, Takahisa; Iwata, Kinjiro; Okumura, Terufumi; Hoshino, Daisaku.

    1992-01-01

    Magnetic resonance imaging (MRI) provides a noninvasive and very important method of investigating spinal-cord injuries. By means of MRI we examined 36 patients with spinal injuries, 34 of them in the acute stage. 19 cases had complete spinal-cord injury with paraplegia, while 17 cases had incomplete spinal-cord injury. MRI showed the injured spinal-cord in the acute stage to be partially swollen, with a high signal intensity in the T 2 -weighted images. In the chronic stage, the injured cord may show atrophic changes with a post-traumatic cavity or myelomalacia, which appears as a high-signal-intensity lesion in the T 2 -weighted images and as a low-signal intensity in the T 1 -weighted images. The cases with complete spinal injuries showed a high signal intensity at the wide level, and these prognoses were poor. The cases with incomplete injuries showed normal findings or a high-signal-intensity spot. In the Gd-DTPA enhanced images, the injured cords were enhanced very well in the subchronic stage. MRI is thus found to be useful in the diagnosis of spinal injuries; it also demonstrates a potential for predicting the neurological prognosis. (author)

  1. Management of Pediatric Spinal Cord Astrocytomas: Outcomes With Adjuvant Radiation

    International Nuclear Information System (INIS)

    Guss, Zachary D.; Moningi, Shalini; Jallo, George I.; Cohen, Kenneth J.; Wharam, Moody D.; Terezakis, Stephanie A.

    2013-01-01

    Purpose: Pediatric intramedullary spinal cord tumors are exceedingly rare; in the United States, 100 to 200 cases are recognized annually, of these, most are astrocytomas. The purpose of this study is to report the outcomes in pediatric patients with spinal cord astrocytomas treated at a tertiary care center. Methods and Materials: An institutional review board-approved retrospective single-institution study was performed for pediatric patients with spinal cord astrocytomas treated at our hospital from 1990 to 2010. The patients were evaluated on the extent of resection, progression-free survival (PFS), and development of radiation-related toxicities. Kaplan-Meier curves and multivariate regression model methods were used for analysis. Results: Twenty-nine patients were included in the study, 24 with grade 1 or 2 (low-grade) tumors and 5 with grade 3 or 4 (high-grade) tumors. The median follow-up time was 55 months (range, 1-215 months) for patients with low-grade tumors and 17 months (range, 10-52 months) for those with high-grade tumors. Thirteen patients in the cohort received chemotherapy. All patients underwent at least 1 surgical resection. Twelve patients received radiation therapy to a median radiation dose of 47.5 Gy (range, 28.6-54.0 Gy). Fifteen patients with low-grade tumors and 1 patient with a high-grade tumor exhibited stable disease at the last follow-up visit. Acute toxicities of radiation therapy were low grade, whereas long-term sequelae were infrequent and manageable when they arose. All patients with low-grade tumors were alive at the last follow-up visit, compared with 1 patient with a high-grade tumor. Conclusion: Primary pediatric spinal cord astrocytomas vary widely in presentation and clinical course. Histopathologic grade remains a major prognostic factor. Patients with low-grade tumors tend to have excellent disease control and long-term survival compared to those with high-grade tumors. This experience suggests that radiation therapy

  2. Management of Pediatric Spinal Cord Astrocytomas: Outcomes With Adjuvant Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Guss, Zachary D.; Moningi, Shalini [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Hospital, Baltimore, Maryland (United States); Jallo, George I. [Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland (United States); Cohen, Kenneth J. [Division of Pediatric Oncology, Johns Hopkins Hospital, Baltimore, Maryland (United States); Wharam, Moody D. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Hospital, Baltimore, Maryland (United States); Terezakis, Stephanie A., E-mail: stereza1@jhmi.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Hospital, Baltimore, Maryland (United States)

    2013-04-01

    Purpose: Pediatric intramedullary spinal cord tumors are exceedingly rare; in the United States, 100 to 200 cases are recognized annually, of these, most are astrocytomas. The purpose of this study is to report the outcomes in pediatric patients with spinal cord astrocytomas treated at a tertiary care center. Methods and Materials: An institutional review board-approved retrospective single-institution study was performed for pediatric patients with spinal cord astrocytomas treated at our hospital from 1990 to 2010. The patients were evaluated on the extent of resection, progression-free survival (PFS), and development of radiation-related toxicities. Kaplan-Meier curves and multivariate regression model methods were used for analysis. Results: Twenty-nine patients were included in the study, 24 with grade 1 or 2 (low-grade) tumors and 5 with grade 3 or 4 (high-grade) tumors. The median follow-up time was 55 months (range, 1-215 months) for patients with low-grade tumors and 17 months (range, 10-52 months) for those with high-grade tumors. Thirteen patients in the cohort received chemotherapy. All patients underwent at least 1 surgical resection. Twelve patients received radiation therapy to a median radiation dose of 47.5 Gy (range, 28.6-54.0 Gy). Fifteen patients with low-grade tumors and 1 patient with a high-grade tumor exhibited stable disease at the last follow-up visit. Acute toxicities of radiation therapy were low grade, whereas long-term sequelae were infrequent and manageable when they arose. All patients with low-grade tumors were alive at the last follow-up visit, compared with 1 patient with a high-grade tumor. Conclusion: Primary pediatric spinal cord astrocytomas vary widely in presentation and clinical course. Histopathologic grade remains a major prognostic factor. Patients with low-grade tumors tend to have excellent disease control and long-term survival compared to those with high-grade tumors. This experience suggests that radiation therapy

  3. Pain relief by Cyberknife radiosurgery for spinal metastasis.

    Science.gov (United States)

    Lee, Sunyoung; Chun, Mison

    2012-01-01

    To report pain relief effect in patients with spinal metastases treated with Cyberknife® and to analyze the factors associated with pain relapse after initial pain relief. We retrospectively analyzed patients with spinal metastasis treated with stereotactic body radiosurgery between April 2007 and June 2009. A total of 57 patients with 73 lesions were available for analysis with a median follow-up of 6.8 months (range, 1-30). Pain was assessed by a verbal/visual analogue scale at each visit: from 0 to 10. Pain relief was defined as a decrease of at least three levels of the pain score without an increase in analgesic use. Complete relief was defined as no analgesics or a score 0 or 1. Pain relief was achieved in 88% of the lesions, with complete relief in 51% within 7 days from the start of radiosurgery. The median duration of pain relief was 3.2 months (range, 1-30). Pain reappeared in 16 patients (27%). Spinal cord compression (P = 0.001) and performance status (P = 0.01) were predictive of pain relapse by multivariate Cox analysis. All 6 patients treated with solitary spinal metastasis experienced pain relief; 5 of them were alive without evidence of disease at a median of 16 months (range, 7-30). As previous studies have shown, our study confirms that pain relief with spinal radiosurgery is around 90%. In particular, long-term pain relief and disease control was observed in patients with solitary spinal metastasis.

  4. Development and testing of a fast Fourier transform high dynamic-range spectral diagnostics for millimeter wave characterization

    International Nuclear Information System (INIS)

    Thoen, D. J.; Bongers, W. A.; Westerhof, E.; Baar, M. R. de; Berg, M. A. van den; Beveren, V. van; Goede, A. P. H.; Graswinckel, M. F.; Schueller, F. C.; Oosterbeek, J. W.; Buerger, A.; Hennen, B. A.

    2009-01-01

    A fast Fourier transform (FFT) based wide range millimeter wave diagnostics for spectral characterization of scattered millimeter waves in plasmas has been successfully brought into operation. The scattered millimeter waves are heterodyne downconverted and directly digitized using a fast analog-digital converter and a compact peripheral component interconnect computer. Frequency spectra are obtained by FFT in the time domain of the intermediate frequency signal. The scattered millimeter waves are generated during high power electron cyclotron resonance heating experiments on the TEXTOR tokamak and demonstrate the performance of the diagnostics and, in particular, the usability of direct digitizing and Fourier transformation of millimeter wave signals. The diagnostics is able to acquire 4 GHz wide spectra of signals in the range of 136-140 GHz. The rate of spectra is tunable and has been tested between 200 000 spectra/s with a frequency resolution of 100 MHz and 120 spectra/s with a frequency resolution of 25 kHz. The respective dynamic ranges are 52 and 88 dB. Major benefits of the new diagnostics are a tunable time and frequency resolution due to postdetection, near-real time processing of the acquired data. This diagnostics has a wider application in astrophysics, earth observation, plasma physics, and molecular spectroscopy for the detection and analysis of millimeter wave radiation, providing high-resolution spectra at high temporal resolution and large dynamic range.

  5. Novel methodology for wide-ranged multistage morphing waverider based on conical theory

    Science.gov (United States)

    Liu, Zhen; Liu, Jun; Ding, Feng; Xia, Zhixun

    2017-11-01

    This study proposes the wide-ranged multistage morphing waverider design method. The flow field structure and aerodynamic characteristics of multistage waveriders are also analyzed. In this method, the multistage waverider is generated in the same conical flowfield, which contains a free-stream surface and different compression-stream surfaces. The obtained results show that the introduction of the multistage waverider design method can solve the problem of aerodynamic performance deterioration in the off-design state and allow the vehicle to always maintain the optimal flight state. The multistage waverider design method, combined with transfiguration flight strategy, can lead to greater design flexibility and the optimization of hypersonic wide-ranged waverider vehicles.

  6. Multi-stage LLC resonant converters designed for wide output voltage ranges

    OpenAIRE

    Tsang, C.-W.; Bingham, C. M.; Foster, M. P.; Stone, D. A.; Leech, J. M.

    2016-01-01

    The paper describes a novel multi-stage LLC resonant converter topology for facilitating wide output voltage ranges. This is achieved by combining the gain range of a capacitor-diode clamped LLC resonant converter with that of a traditional LLC resonant converter. A prototype converter is designed and commissioned to illustrate the design procedure and demonstrate resulting operational characteristics. Experimental results are used to show operational characteristics of the proposed conver...

  7. Tribological behavior and self-healing functionality of TiNbCN-Ag coatings in wide temperature range

    Science.gov (United States)

    Bondarev, A. V.; Kiryukhantsev-Korneev, Ph. V.; Levashov, E. A.; Shtansky, D. V.

    2017-02-01

    Ag- and Nb-doped TiCN coatings with about 2 at.% of Nb and Ag contents varied between 4.0 and 15.1 at.% were designed as promising materials for tribological applications in a wide temperature range. We report on the structure, mechanical, and tribological properties of TiNbCN-Ag coatings fabricated by simultaneous co-sputtering of TiC0.5 + 10%Nb2C and Ag targets in comparison with those of Ag-free coating. The tribological characteristics were evaluated during constant-temperature tests both at room temperature and 300 °C, as well as during dynamic temperature ramp tests in the range of 25-700 °C. The coating structure and elemental composition were studied by means of X-ray diffraction, scanning and transmission electron microscopy, and glow discharge optical emission spectroscopy. The coating microstructures and elemental compositions inside wear tracks, as well as the wear products, were examined by scanning electron microscopy, energy-dispersive spectroscopy, and Raman spectroscopy. We demonstrate that simultaneous alloying with Nb and Ag permits to overcome the main drawbacks of TiCN coatings such as their relatively high values of friction coefficient at elevated temperatures and low oxidation resistance. It is shown that a relatively high amount of Ag (15 at.%) is required to provide enhanced tribological behavior in a wide temperature range of 25-700 °C. In addition, the prepared Ag-doped coatings demonstrated active oxidation protection and self-healing functionality due to the segregation of Ag metallic particles in damage areas such as cracks, pin-holes, or oxidation sites.

  8. Multibloc system electronic equipment: D.C. linear - logarithmic amplifier and periodmeter and wide range (pulses, fluctuations and direct current) measuring set

    International Nuclear Information System (INIS)

    Guerre, J.; Plaige, Y.; Vaux, C.

    1974-01-01

    The requirements which have led to the design of a specific equipment for reactor neutron control (Multibloc system) are briefly recalled. It is shown how, for reasons of saving the cost of installation, the development tended towards a multifunction performance from signals delivered by one detector. Two major achievments in accordance with the above trend are described: the D.C. linear - logarithmic amplifier and periodmeter, and the wide dynamics range measuring set [fr

  9. The Lesioned Spinal Cord Is a “New” Spinal Cord: Evidence from Functional Changes after Spinal Injury in Lamprey

    Science.gov (United States)

    Parker, David

    2017-01-01

    Finding a treatment for spinal cord injury (SCI) focuses on reconnecting the spinal cord by promoting regeneration across the lesion site. However, while regeneration is necessary for recovery, on its own it may not be sufficient. This presumably reflects the requirement for regenerated inputs to interact appropriately with the spinal cord, making sub-lesion network properties an additional influence on recovery. This review summarizes work we have done in the lamprey, a model system for SCI research. We have compared locomotor behavior (swimming) and the properties of descending inputs, locomotor networks, and sensory inputs in unlesioned animals and animals that have received complete spinal cord lesions. In the majority (∼90%) of animals swimming parameters after lesioning recovered to match those in unlesioned animals. Synaptic inputs from individual regenerated axons also matched the properties in unlesioned animals, although this was associated with changes in release parameters. This suggests against any compensation at these synapses for the reduced descending drive that will occur given that regeneration is always incomplete. Compensation instead seems to occur through diverse changes in cellular and synaptic properties in locomotor networks and proprioceptive systems below, but also above, the lesion site. Recovery of locomotor performance is thus not simply the reconnection of the two sides of the spinal cord, but reflects a distributed and varied range of spinal cord changes. While locomotor network changes are insufficient on their own for recovery, they may facilitate locomotor outputs by compensating for the reduction in descending drive. Potentiated sensory feedback may in turn be a necessary adaptation that monitors and adjusts the output from the “new” locomotor network. Rather than a single aspect, changes in different components of the motor system and their interactions may be needed after SCI. If these are general features, and where

  10. Central nociceptive sensitization vs. spinal cord training: Opposing forms of plasticity that dictate function after complete spinal cord injury

    Directory of Open Access Journals (Sweden)

    Adam R Ferguson

    2012-10-01

    Full Text Available The spinal cord demonstrates several forms of plasticity that resemble brain-dependent learning and memory. Among the most studied form of spinal plasticity is spinal memory for noxious (nociceptive stimulation. Numerous papers have described central pain as a spinally-stored memory that enhances future responses to cutaneous stimulation. This phenomenon, known as central sensitization, has broad relevance to a range of pathological conditions. Work from the spinal cord injury (SCI field indicates that the lumbar spinal cord demonstrates several other forms of plasticity, including formal learning and memory. After complete thoracic SCI, the lumbar spinal cord can be trained by delivering stimulation to the hindleg when the leg is extended. In the presence of this response-contingent stimulation the spinal cord rapidly learns to hold the leg in a flexed position, a centrally mediated effect that meets the formal criteria for instrumental (response-outcome learning. Instrumental flexion training produces a central change in spinal plasticity that enables future spinal learning on both the ipsilateral and contralateral leg. However, if stimulation is given in a response-independent manner, the spinal cord develops central maladaptive plasticity that undermines future spinal learning on both legs. The present paper tests for interactions between spinal cord training and central nociceptive sensitization after complete spinal cord transection. We found that spinal training alters future central sensitization by intradermal formalin (24 h post-training. Conversely intradermal formalin impaired future spinal learning (24 h post-injection. Because the NMDA receptor has been implicated in formalin-induced central sensitization, we tested whether pretreatment with NMDA affects spinal learning. We found intrathecal NMDA impaired learning in a dose-dependent fashion, and that this effect endures for at least 24h. These data provide strong evidence for an

  11. Correlation of shoulder range of motion limitations at discharge with limitations in activities and participation one year later in persons with spinal cord injury

    NARCIS (Netherlands)

    Eriks-Hoogland, Inge E.; de Groot, Sonja; Post, Marcel W. M.; van der Woude, Lucas H. V.

    Objective: To study the correlation between limited shoulder range of motion in persons with spinal cord injury at discharge and the performance of activities, wheeling performance, transfers and participation one year later. Design: Multicentre prospective cohort study. Subjects: A total of 146

  12. Cervical spinal canal narrowing and cervical neurologi-cal injuries

    Directory of Open Access Journals (Sweden)

    ZHANG Ling

    2012-04-01

    Full Text Available 【Abstract】Cervical spinal canal narrowing can lead to injury of the spinal cord and neurological symptoms in-cluding neck pain, headache, weakness and parasthesisas. According to previous and recent clinical researches, we investigated the geometric parameters of normal cervical spinal canal including the sagittal and transverse diameters as well as Torg ratio. The mean sagittal diameter of cervical spinal canal at C 1 to C 7 ranges from 15.33 mm to 20.46 mm, the mean transverse diameter at the same levels ranges from 24.45 mm to 27.00 mm and the mean value of Torg ratio is 0.96. With respect to narrow cervical spinal canal, the following charaterstics are found: firstly, extension of the cervical spine results in statistically significant stenosis as compared with the flexed or neutral positions; secondly, females sustain cervical spinal canal narrowing more easily than males; finally, the consistent narrowest cervical canal level is at C 4 for all ethnicity, but there is a slight variation in the sagittal diameter of cervical spinal stenosis (≤14 mm in Whites, ≤ 12 mm in Japanese, ≤13.7 mm in Chinese. Narrow sagittal cervical canal diameter brings about an increased risk of neurological injuries in traumatic, degenerative and inflam-matory conditions and is related with extension of cervical spine, gender, as well as ethnicity. It is hoped that this re-view will be helpful in diagnosing spinal cord and neuro-logical injuries with the geometric parameters of cervical spine in the future. Key words: Spinal cord injuries; Spinal stenosis; Trauma, nervous system

  13. Enhanced pre-synaptic glutamate release in deep-dorsal horn contributes to calcium channel alpha-2-delta-1 protein-mediated spinal sensitization and behavioral hypersensitivity

    Directory of Open Access Journals (Sweden)

    Dickenson Anthony H

    2009-02-01

    Full Text Available Abstract Nerve injury-induced expression of the spinal calcium channel alpha-2-delta-1 subunit (Cavα2δ1 has been shown to mediate behavioral hypersensitivity through a yet identified mechanism. We examined if this neuroplasticity modulates behavioral hypersensitivity by regulating spinal glutamatergic neurotransmission in injury-free transgenic mice overexpressing the Cavα2δ1 proteins in neuronal tissues. The transgenic mice exhibited hypersensitivity to mechanical stimulation (allodynia similar to the spinal nerve ligation injury model. Intrathecally delivered antagonists for N-methyl-D-aspartate (NMDA and α-amino-3-hydroxyl-5-methylisoxazole-4-propionic acid (AMPA/kainate receptors, but not for the metabotropic glutamate receptors, caused a dose-dependent allodynia reversal in the transgenic mice without changing the behavioral sensitivity in wild-type mice. This suggests that elevated spinal Cavα2δ1 mediates allodynia through a pathway involving activation of selective glutamate receptors. To determine if this is mediated by enhanced spinal neuronal excitability or pre-synaptic glutamate release in deep-dorsal horn, we examined wide-dynamic-range (WDR neuron excitability with extracellular recording and glutamate-mediated excitatory postsynaptic currents with whole-cell patch recording in deep-dorsal horn of the Cavα2δ1 transgenic mice. Our data indicated that overexpression of Cavα2δ1 in neuronal tissues led to increased frequency, but not amplitude, of miniature excitatory post synaptic currents mediated mainly by AMPA/kainate receptors at physiological membrane potentials, and also by NMDA receptors upon depolarization, without changing the excitability of WDR neurons to high intensity stimulation. Together, these findings support a mechanism of Cavα2δ1-mediated spinal sensitization in which elevated Cavα2δ1 causes increased pre-synaptic glutamate release that leads to reduced excitation thresholds of post-synaptic dorsal

  14. Enhanced pre-synaptic glutamate release in deep-dorsal horn contributes to calcium channel alpha-2-delta-1 protein-mediated spinal sensitization and behavioral hypersensitivity

    Science.gov (United States)

    Nguyen, David; Deng, Ping; Matthews, Elizabeth A; Kim, Doo-Sik; Feng, Guoping; Dickenson, Anthony H; Xu, Zao C; Luo, Z David

    2009-01-01

    Nerve injury-induced expression of the spinal calcium channel alpha-2-delta-1 subunit (Cavα2δ1) has been shown to mediate behavioral hypersensitivity through a yet identified mechanism. We examined if this neuroplasticity modulates behavioral hypersensitivity by regulating spinal glutamatergic neurotransmission in injury-free transgenic mice overexpressing the Cavα2δ1 proteins in neuronal tissues. The transgenic mice exhibited hypersensitivity to mechanical stimulation (allodynia) similar to the spinal nerve ligation injury model. Intrathecally delivered antagonists for N-methyl-D-aspartate (NMDA) and α-amino-3-hydroxyl-5-methylisoxazole-4-propionic acid (AMPA)/kainate receptors, but not for the metabotropic glutamate receptors, caused a dose-dependent allodynia reversal in the transgenic mice without changing the behavioral sensitivity in wild-type mice. This suggests that elevated spinal Cavα2δ1 mediates allodynia through a pathway involving activation of selective glutamate receptors. To determine if this is mediated by enhanced spinal neuronal excitability or pre-synaptic glutamate release in deep-dorsal horn, we examined wide-dynamic-range (WDR) neuron excitability with extracellular recording and glutamate-mediated excitatory postsynaptic currents with whole-cell patch recording in deep-dorsal horn of the Cavα2δ1 transgenic mice. Our data indicated that overexpression of Cavα2δ1 in neuronal tissues led to increased frequency, but not amplitude, of miniature excitatory post synaptic currents mediated mainly by AMPA/kainate receptors at physiological membrane potentials, and also by NMDA receptors upon depolarization, without changing the excitability of WDR neurons to high intensity stimulation. Together, these findings support a mechanism of Cavα2δ1-mediated spinal sensitization in which elevated Cavα2δ1 causes increased pre-synaptic glutamate release that leads to reduced excitation thresholds of post-synaptic dorsal horn neurons to innocuous

  15. Context-dependent JPEG backward-compatible high-dynamic range image compression

    Science.gov (United States)

    Korshunov, Pavel; Ebrahimi, Touradj

    2013-10-01

    High-dynamic range (HDR) imaging is expected, together with ultrahigh definition and high-frame rate video, to become a technology that may change photo, TV, and film industries. Many cameras and displays capable of capturing and rendering both HDR images and video are already available in the market. The popularity and full-public adoption of HDR content is, however, hindered by the lack of standards in evaluation of quality, file formats, and compression, as well as large legacy base of low-dynamic range (LDR) displays that are unable to render HDR. To facilitate the wide spread of HDR usage, the backward compatibility of HDR with commonly used legacy technologies for storage, rendering, and compression of video and images are necessary. Although many tone-mapping algorithms are developed for generating viewable LDR content from HDR, there is no consensus of which algorithm to use and under which conditions. We, via a series of subjective evaluations, demonstrate the dependency of the perceptual quality of the tone-mapped LDR images on the context: environmental factors, display parameters, and image content itself. Based on the results of subjective tests, it proposes to extend JPEG file format, the most popular image format, in a backward compatible manner to deal with HDR images also. An architecture to achieve such backward compatibility with JPEG is proposed. A simple implementation of lossy compression demonstrates the efficiency of the proposed architecture compared with the state-of-the-art HDR image compression.

  16. Time course of dynamic range adaptation in the auditory nerve

    Science.gov (United States)

    Wang, Grace I.; Dean, Isabel; Delgutte, Bertrand

    2012-01-01

    Auditory adaptation to sound-level statistics occurs as early as in the auditory nerve (AN), the first stage of neural auditory processing. In addition to firing rate adaptation characterized by a rate decrement dependent on previous spike activity, AN fibers show dynamic range adaptation, which is characterized by a shift of the rate-level function or dynamic range toward the most frequently occurring levels in a dynamic stimulus, thereby improving the precision of coding of the most common sound levels (Wen B, Wang GI, Dean I, Delgutte B. J Neurosci 29: 13797–13808, 2009). We investigated the time course of dynamic range adaptation by recording from AN fibers with a stimulus in which the sound levels periodically switch from one nonuniform level distribution to another (Dean I, Robinson BL, Harper NS, McAlpine D. J Neurosci 28: 6430–6438, 2008). Dynamic range adaptation occurred rapidly, but its exact time course was difficult to determine directly from the data because of the concomitant firing rate adaptation. To characterize the time course of dynamic range adaptation without the confound of firing rate adaptation, we developed a phenomenological “dual adaptation” model that accounts for both forms of AN adaptation. When fitted to the data, the model predicts that dynamic range adaptation occurs as rapidly as firing rate adaptation, over 100–400 ms, and the time constants of the two forms of adaptation are correlated. These findings suggest that adaptive processing in the auditory periphery in response to changes in mean sound level occurs rapidly enough to have significant impact on the coding of natural sounds. PMID:22457465

  17. Transcutaneous Spinal Direct Current Stimulation (tsDCS

    Directory of Open Access Journals (Sweden)

    Filippo eCogiamanian

    2012-07-01

    Full Text Available In the past ten years renewed interest has centered on non-invasive transcutaneous weak direct currents applied over the scalp to modulate cortical excitability (brain polarization or transcranial direct current stimulation, tDCS. Extensive literature shows that tDCS induces marked changes in cortical excitability that outlast stimulation.Aiming at developing a new, non invasive, approach to spinal cord neuromodulation we assessed the after-effects of thoracic transcutaneous spinal DC stimulation (tsDCS on somatosensory potentials (SEPs evoked in healthy subjects by posterior tibial nerve (PTN stimulation. Our findings showed that thoracic anodal tsDCS depresses the cervico-medullary PTN-SEP component (P30 without eliciting adverse effects. tsDCS also modulates post-activation H-reflex dynamics. Later works further confirmed that transcutaneous electric fields modulate spinal cord function. Subsequent studies in our laboratory showed that tsDCS modulates the flexion reflex in the human lower limb. Besides influencing the laser evoked potentials, tsDCS increases pain tolerance in healthy subjects. Hence, though the underlying mechanisms remain speculative, tsDCS modulates activity in lemniscal, spinothalamic and segmental motor systems.Here we review currently available experimental evidence that non-invasive spinal cord stimulation influences spinal function in humans and argue that, by focally modulating spinal excitability, tsDCS could provide a novel therapeutic tool complementary to drugs and invasive spinal cord stimulation in managing various pathologic conditions, including pain.

  18. A high sensitive 66 dB linear dynamic range receiver for 3-D laser radar

    Science.gov (United States)

    Ma, Rui; Zheng, Hao; Zhu, Zhangming

    2017-08-01

    This study presents a CMOS receiver chip realized in 0.18 μm standard CMOS technology and intended for high precision 3-D laser radar. The chip includes an adjustable gain transimpedance pre-amplifier, a post-amplifier and two timing comparators. An additional feedback is employed in the regulated cascode transimpedance amplifier to decrease the input impedance, and a variable gain transimpedance amplifier controlled by digital switches and analog multiplexer is utilized to realize four gain modes, extending the input dynamic range. The measurement shows that the highest transimpedance of the channel is 50 k {{Ω }}, the uncompensated walk error is 1.44 ns in a wide linear dynamic range of 66 dB (1:2000), and the input referred noise current is 2.3 pA/\\sqrt{{Hz}} (rms), resulting in a very low detectable input current of 1 μA with SNR = 5.

  19. The transformation of spinal curvature into spinal deformity: pathological processes and implications for treatment

    Directory of Open Access Journals (Sweden)

    Hawes Martha C

    2006-03-01

    Full Text Available Abstract Background This review summarizes what is known about the pathological processes (e.g. structural and functional changes, by which spinal curvatures develop and evolve into spinal deformities. Methods Comprehensive review of articles (English language only published on 'scoliosis,' whose content yielded data on the pathological changes associated with spinal curvatures. Medline, Science Citation Index and other searches yielded > 10,000 titles each of which was surveyed for content related to 'pathology' and related terms such as 'etiology,' 'inheritance,' 'pathomechanism,' 'signs and symptoms.' Additional resources included all books published on 'scoliosis' and available through the Arizona Health Sciences Library, Interlibrary Loan, or through direct contact with the authors or publishers. Results A lateral curvature of the spine–'scoliosis'–can develop in association with postural imbalance due to genetic defects and injury as well as pain and scarring from trauma or surgery. Irrespective of the factor that triggers its appearance, a sustained postural imbalance can result, over time, in establishment of a state of continuous asymmetric loading relative to the spinal axis. Recent studies support the longstanding hypothesis that spinal deformity results directly from such postural imbalance, irrespective of the primary trigger, because the dynamics of growth within vertebrae are altered by continuous asymmetric mechanical loading. These data suggest that, as long as growth potential remains, evolution of a spinal curvature into a spinal deformity can be prevented by reversing the state of continuous asymmetric loading. Conclusion Spinal curvatures can routinely be diagnosed in early stages, before pathological deformity of the vertebral elements is induced in response to asymmetric loading. Current clinical approaches involve 'watching and waiting' while mild reversible spinal curvatures develop into spinal deformities with

  20. Spatiotemporal dynamics of rhythmic spinal interneurons measured with two-photon calcium imaging and coherence analysis.

    Science.gov (United States)

    Kwan, Alex C; Dietz, Shelby B; Zhong, Guisheng; Harris-Warrick, Ronald M; Webb, Watt W

    2010-12-01

    In rhythmic neural circuits, a neuron often fires action potentials with a constant phase to the rhythm, a timing relationship that can be functionally significant. To characterize these phase preferences in a large-scale, cell type-specific manner, we adapted multitaper coherence analysis for two-photon calcium imaging. Analysis of simulated data showed that coherence is a simple and robust measure of rhythmicity for calcium imaging data. When applied to the neonatal mouse hindlimb spinal locomotor network, the phase relationships between peak activity of >1,000 ventral spinal interneurons and motor output were characterized. Most interneurons showed rhythmic activity that was coherent and in phase with the ipsilateral motor output during fictive locomotion. The phase distributions of two genetically identified classes of interneurons were distinct from the ensemble population and from each other. There was no obvious spatial clustering of interneurons with similar phase preferences. Together, these results suggest that cell type, not neighboring neuron activity, is a better indicator of an interneuron's response during fictive locomotion. The ability to measure the phase preferences of many neurons with cell type and spatial information should be widely applicable for studying other rhythmic neural circuits.

  1. Morphological study of the spinal canal content for subarachnoid endoscopy.

    Science.gov (United States)

    Zaaroor, M; Kósa, G; Peri-Eran, A; Maharil, I; Shoham, M; Goldsher, D

    2006-08-01

    This study was designed to examine the morphology of the spinal dural sac and contents, using magnetic resonance imaging in order to define the inner geometrical dimensions that confine the manoeuvre of an endoscope inserted in the lumbar region and along the thoracic and cervical spine. The morphology of the spine has been studied since the development of myelography. However, most studies have measured the diameters of the spinal cord only, not the size of the subarachnoid space. In addition, the few studies available on the subarachnoid space have focused on the cervical spine, leaving a near-complete dearth of data on the subarachnoid space dimensions along the thoracic spine. Based on MRI images of the spine from 42 patients, the dimensions of the spinal cord, dural sac, and subarachnoid space were measured at mid-vertebral and inter-vertebral disc levels. It was found that at each selected transverse level, the subarachnoid space tends to be symmetrical on the right and left sides of the cord, and measures 2.5 mm on average. However, the posterior and anterior segments, measured on the mid-sagittal plane, are generally asymmetrical and vary widely in size, ranging from 1 to 5 mm. These measurements match those found in previous studies, where these are available. The coefficient of variance for the dimensions of the subarachnoid space is as high as 42.4%, while that for the dimensions of the spinal cord is 10-15%. The findings presented here expand our knowledge of the spinal canal's morphology, and show that an endoscope designed to travel within the subarachnoid space must be smaller than 2.5 mm in diameter.

  2. Twiddler's syndrome in spinal cord stimulation.

    Science.gov (United States)

    Al-Mahfoudh, Rafid; Chan, Yuen; Chong, Hsu Pheen; Farah, Jibril Osman

    2016-01-01

    The aims are to present a case series of Twiddler's syndrome in spinal cord stimulators with analysis of the possible mechanism of this syndrome and discuss how this phenomenon can be prevented. Data were collected retrospectively between 2007 and 2013 for all patients presenting with failure of spinal cord stimulators. The diagnostic criterion for Twiddler's syndrome is radiological evidence of twisting of wires in the presence of failure of spinal cord stimulation. Our unit implants on average 110 spinal cord stimulators a year. Over the 5-year study period, all consecutive cases of spinal cord stimulation failure were studied. Three patients with Twiddler's syndrome were identified. Presentation ranged from 4 to 228 weeks after implantation. Imaging revealed repeated rotations and twisting of the wires of the spinal cord stimulators leading to hardware failure. To the best of our knowledge this is the first reported series of Twiddler's syndrome with implantable pulse generators (IPGs) for spinal cord stimulation. Hardware failure is not uncommon in spinal cord stimulation. Awareness and identification of Twiddler's syndrome may help prevent its occurrence and further revisions. This may be achieved by implanting the IPG in the lumbar region subcutaneously above the belt line. Psychological intervention may have a preventative role for those who are deemed at high risk of Twiddler's syndrome from initial psychological screening.

  3. Spinal Cord Subependymoma Surgery : A Multi-Institutional Experience.

    Science.gov (United States)

    Yuh, Woon Tak; Chung, Chun Kee; Park, Sung-Hye; Kim, Ki-Jeong; Lee, Sun-Ho; Kim, Kyoung-Tae

    2018-03-01

    A spinal cord subependymoma is an uncommon, indolent, benign spinal cord tumor. It is radiologically similar to a spinal cord ependymoma, but surgical findings and outcomes differ. Gross total resection of the tumor is not always feasible. The present study was done to determine the clinical, radiological and pathological characteristics of spinal cord subependymomas. We retrospectively reviewed the medical records of ten spinal cord subependymoma patients (M : F=4 : 6; median 38 years; range, 21-77) from four institutions. The most common symptoms were sensory changes and/or pain in eight patients, followed by motor weakness in six. The median duration of symptoms was 9.5 months. Preoperative radiological diagnosis was ependymoma in seven and astrocytoma in three. The tumors were located eccentrically in six and were not enhanced in six. Gross total resection of the tumor was achieved in five patients, whereas subtotal or partial resection was inevitable in the other five patients due to a poor dissection plane. Adjuvant radiotherapy was performed in two patients. Neurological deterioration occurred in two patients; transient weakness in one after subtotal resection and permanent weakness after gross total resection in the other. Recurrence or regrowth of the tumor was not observed during the median 31.5 months follow-up period (range, 8-89). Spinal cord subependymoma should be considered when the tumor is located eccentrically and is not dissected easily from the spinal cord. Considering the rather indolent nature of spinal cord subependymomas, subtotal removal without the risk of neurological deficit is another option.

  4. Doped silicene: Evidence of a wide stability range

    KAUST Repository

    Cheng, Yingchun

    2011-06-17

    The effects of doping on the lattice structure, electronic structure, phonon spectrum, and electron-phonon coupling of low-buckling silicene are studied by first-principles calculations. Although the lattice is found to be very sensitive to the carrier concentration, it is stable in a wide doping range. The frequencies of the E2g-Γ and A′-K Raman modes can be used to probe the carrier concentration. In addition, the phonon dispersion displays Kohn anomalies at the Γ and K points which are reduced by doping. This implies that the electron-phonon coupling cannot be neglected in field-effect transistor applications. Copyright © 2011 EPLA.

  5. Driving Safety after Spinal Surgery: A Systematic Review.

    Science.gov (United States)

    Alhammoud, Abduljabbar; Alkhalili, Kenan; Hannallah, Jack; Ibeche, Bashar; Bajammal, Sohail; Baco, Abdul Moeen

    2017-04-01

    This study aimed to assess driving reaction times (DRTs) after spinal surgery to establish a timeframe for safe resumption of driving by the patient postoperatively. The MEDLINE and Google Scholar databases were analyzed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) Statement for clinical studies that investigated changes in DRTs following cervical and lumbar spinal surgery. Changes in DRTs and patients' clinical presentation, pathology, anatomical level affected, number of spinal levels involved, type of intervention, pain level, and driving skills were assessed. The literature search identified 12 studies that investigated postoperative DRTs. Six studies met the inclusion criteria; five studies assessed changes in DRT after lumbar spine surgery and two studies after cervical spina surgery. The spinal procedures were selective nerve root block, anterior cervical discectomy and fusion, and lumbar fusion and/ordecompression. DRTs exhibited variable responses to spinal surgery and depended on the patients' clinical presentation, spinal level involved, and type of procedure performed. The evidence regarding the patients' ability to resume safe driving after spinal surgery is scarce. Normalization of DRT or a return of DRT to pre-spinal intervention level is a widely accepted indicator for safe driving, with variable levels of statistical significance owing to multiple confounding factors. Considerations of the type of spinal intervention, pain level, opioid consumption, and cognitive function should be factored in the assessment of a patient's ability to safely resume driving.

  6. A rare complication of spinal anesthesia: Intracranial subdural hemorrhage

    Directory of Open Access Journals (Sweden)

    Cengiz Kaplan

    2015-02-01

    Full Text Available Spinal (subarachnoid anesthesia (SA is a widely used general-purpose anesthesia. Postdural Puncture Headaches (PDPHs represent one of the principal complications of spinal anesthesia. A 21-year-old man underwent inguinal herniorrhaphy and orchiectomy using spinal anesthesia. Postoperatively, our patient started to have a headache with nausea. The patient received symptomatic therapy, but the severe headache persisted even in the supine position, with his vital signs and neurological examination being normal. Cranial MRI showed a bilateral subdural hematoma from his frontal to temporal region. A postdural puncture headache is a frequent complication after spinal anesthesia. However, serious complications, such as an intracranial subdural hemorrhage, can rarely occur. [Arch Clin Exp Surg 2015; 4(1.000: 54-56

  7. Electrophysiological evidence for voltage-gated calcium channel 2 (Cav2) modulation of mechano- and thermosensitive spinal neuronal responses in a rat model of osteoarthritis.

    Science.gov (United States)

    Rahman, W; Patel, R; Dickenson, A H

    2015-10-01

    Osteoarthritis (OA) remains one of the greatest healthcare burdens in western society, with chronic debilitating pain-dominating clinical presentation yet therapeutic strategies are inadequate in many patients. Development of better analgesics is contingent on improved understanding of the molecular mechanisms mediating OA pain. Voltage-gated calcium channels 2.2 (Cav2.2) play a critical role in spinal nociceptive transmission, therefore blocking Cav2.2 activity represents an attractive opportunity for OA pain treatment, but the only available licensed Cav2.2 antagonist ziconitide (PrilatTM) is of limited use. TROX-1 is an orally available, use dependent and state-selective Cav2 antagonist, exerting its analgesic effect primarily via Cav2.2 blockade, with an improved therapeutic window compared with ziconitide. Using a rat model of monosodium iodoacetate (MIA), 2 mg, induced OA we used in vivo electrophysiology to assess the effects of spinal or systemic administration of TROX-1 on the evoked activity of wide dynamic range spinal dorsal horn neurons in response to electrical, natural mechanical (dynamic brush and von Frey 2, 8, 26 and 6 g) and thermal (40, 45 and 45 °C) stimuli applied to the peripheral receptive field. MIA injection into the knee joint resulted in mechanical hypersensitivity of the ipsilateral hind paw and weight-bearing asymmetry. Spinal administration of TROX-1 (0.1 and 1 μg/50 μl) produced a significant dose-related inhibition of dynamic brush, mechanical (von Frey filament (vF) 8, 26 and 60 g) and noxious thermal-(45 and 48 °C) evoked neuronal responses in MIA rats only. Systemic administration of TROX-1 produced a significant inhibition of the mechanical-(vF 8, 26 and 60 g) evoked neuronal responses in MIA rats. TROX-1 did not produce any significant effect on any neuronal measure in Sham controls. Our in vivo electrophysiological results demonstrate a pathological state-dependent effect of TROX-1, which suggests an increased functional

  8. A wide range gamma monitor with digital display for remote monitoring

    International Nuclear Information System (INIS)

    Risbud, V.H.; Thiagarajan, A.; Gangadharan, P.

    1976-01-01

    A wide range gamma monitor designed for remote monitoring in nuclear facilities is described. The instrument consists of two GM detectors and pre-amplifiers connected by a long coaxial cable to the power supply, scalers and timers and display devices. Automatic selection of detectors range of exposure rate and display (nixie) are achieved with this set up, radiation levels in active areas can easily be displayed in the control room. Other advantages are also pointed out. (A.K.)

  9. Electrophysiological characterization of spinal neurons in different models of diabetes type 1- and type 2-induced neuropathy in rats.

    Science.gov (United States)

    Schuelert, N; Gorodetskaya, N; Just, S; Doods, H; Corradini, L

    2015-04-16

    Diabetic polyneuropathy (DPN) is a devastating complication of diabetes. The underlying pathogenesis of DPN is still elusive and an effective treatment devoid of side effects presents a challenge. There is evidence that in type-1 and -2 diabetes, metabolic and morphological changes lead to peripheral nerve damage and altered central nociceptive transmission, which may contribute to neuropathic pain symptoms. We characterized the electrophysiological response properties of spinal wide dynamic range (WDR) neurons in three diabetic models. The streptozotocin (STZ) model was used as a drug-induced model of type-1 diabetes, and the BioBreeding/Worcester (BB/Wor) and Zucker diabetic fatty (ZDF) rat models were used for genetic DPN models. Data were compared to the respective control group (BB/Wor diabetic-resistant, Zucker lean (ZL) and saline-injected Wistar rat). Response properties of WDR neurons to mechanical stimulation and spontaneous activity were assessed. We found abnormal response properties of spinal WDR neurons in all diabetic rats but not controls. Profound differences between models were observed. In BB/Wor diabetic rats evoked responses were increased, while in ZDF rats spontaneous activity was increased and in STZ rats mainly after discharges were increased. The abnormal response properties of neurons might indicate differential pathological, diabetes-induced, changes in spinal neuronal transmission. This study shows for the first time that specific electrophysiological response properties are characteristic for certain models of DPN and that these might reflect the diverse and complex symptomatology of DPN in the clinic. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  10. Ischemic spinal cord infarction in children without vertebral fracture

    OpenAIRE

    Nance, Jessica R.; Golomb, Meredith R.

    2007-01-01

    Spinal cord infarction in children is a rare condition which is becoming more widely recognized. There are few reports in the pediatric literature characterizing etiology, diagnosis, treament and prognosis. The risk factors for pediatric ischemic spinal cord infarction include obstruction of blood flow associated with cardiovascular compromise or malformation, iatrogenic or traumatic vascular inujury, cerebellar herniation, thrombotic or embolic disease, infection, and vasculitis. In many chi...

  11. Ab initio calculation of the shear viscosity of neon in the liquid and hypercritical state over a wide pressure and temperature range

    Science.gov (United States)

    Eggenberger, Rolf; Gerber, Stefan; Huber, Hanspeter; Searles, Debra; Welker, Marc

    1992-08-01

    The shear viscosity is calculated ab initio for the liquid and hypercritical state, i.e. a previously published potential for Ne 2, obtained from ab initio calculations including electron correlation, is used in classical equilibrium molecular dynamics simulations to obtain the shear viscosity from a Green-Kubo integral. The quality of the results is quite uniform over a large pressure range up to 1000 MPa and a wide temperature range from 26 to 600 K. In most cases the calculated shear viscosity deviates by less than 10% from the experimental value, in general the error being only a few percent.

  12. Tolerance of the Spinal Cord to Stereotactic Radiosurgery: Insights From Hemangioblastomas

    International Nuclear Information System (INIS)

    Daly, Megan E.; Choi, Clara Y.H.; Gibbs, Iris C.; Adler, John R.; Chang, Steven D.; Lieberson, Robert E.; Soltys, Scott G.

    2011-01-01

    Purpose: To evaluate spinal cord dose-volume effects, we present a retrospective review of stereotactic radiosurgery (SRS) treatments for spinal cord hemangioblastomas. Methods and Materials: From November 2001 to July 2008, 27 spinal hemangioblastomas were treated in 19 patients with SRS. Seventeen tumors received a single fraction with a median dose of 20 Gy (range, 18-30 Gy). Ten lesions were treated using 18-25 Gy in two to three sessions. Cord volumes receiving 8, 10, 12, 14, 16, 18, 20, 22, and 24 Gy and dose to 10, 100, 250, 500, 1000, and 2000 mm 3 of cord were determined. Multisession treatments were converted to single-fraction biologically effective dose (SFBED). Results: Single-fraction median cord D max was 22.7 Gy (range, 17.8-30.9 Gy). Median V10 was 454 mm 3 (range, 226-3543 mm 3 ). Median dose to 500 mm 3 cord was 9.5 Gy (range, 5.3-22.5 Gy). Fractionated median SFBED 3 cord D max was 14.1 Gy 3 (range, 12.3-19.4 Gy 3 ). Potential toxicities included a Grade 2 unilateral foot drop 5 months after SRS and 2 cases of Grade 1 sensory deficits. The actuarial 3-year local tumor control estimate was 86%. Conclusions: Despite exceeding commonly cited spinal cord dose constraints, SRS for spinal hemangioblastomas is safe and effective. Consistent with animal experiments, these data support a partial-volume tolerance model for the human spinal cord. Because irradiated cord volumes were generally small, application of these data to other clinical scenarios should be made cautiously. Further prospective studies of spinal radiosurgery are needed.

  13. Re-irradiation of the human spinal cord

    International Nuclear Information System (INIS)

    Sminia, P.; Oldenburger, F.; Hulshof, M.C.C.M.; Slotman, B.J.; Schneider, J.J.

    2002-01-01

    Purpose: Experimental animal data give evidence of long-term recovery of the spinal cord after irradiation. By extrapolation of these data, re-irradiation regimes were designed for eight patients who required palliative radiotherapy. As a consequence of reirradiation, their spinal cords were exposed to cumulative doses exceeding the tolerance dose. Radiobiological and clinical data are presented. Patients and method: Eight patients were re-irradiated on the cervical (n=1), thoracic (n=5) and lumbar (n=2) spinal cord. The time interval between the initial and re-treatment ranged from 4 months to 12.7 years (median: 2.5 years). (Re-)treatment schemes were designed and analyzed on basis of the biologically effective dose (BED) according to the linear-quadratic model. The repair capacity (α/β ratio) for the cervico-thoracic and lumbar spinal cord was assumed to be 2 Gy and 4 Gy, with a BED tolerance of 100 Gy and 84 Gy, respectively. Results: The cumulative irradiation dose applied to the spinal cord varied between 125 and 172% of the BED tolerance . During follow-up, ranging from 33 days to >4.5 years (median: 370 days) none of the patients developed neurological complications. Seven patients died from tumor progression, and one patient is still alive. Conclusion: Long-term recovery of the spinal cord from radiation injury, which has been demonstrated in rodents and primates, may also occur in humans. (orig.) [de

  14. Transplantation dose alters the dynamics of human neural stem cell engraftment, proliferation and migration after spinal cord injury

    Directory of Open Access Journals (Sweden)

    Katja M. Piltti

    2015-09-01

    Full Text Available The effect of transplantation dose on the spatiotemporal dynamics of human neural stem cell (hNSC engraftment has not been quantitatively evaluated in the central nervous system. We investigated changes over time in engraftment/survival, proliferation, and migration of multipotent human central nervous system-derived neural stem cells (hCNS-SCns transplanted at doses ranging from 10,000 to 500,000 cells in spinal cord injured immunodeficient mice. Transplant dose was inversely correlated with measures of donor cell proliferation at 2 weeks post-transplant (WPT and dose-normalized engraftment at 16 WPT. Critically, mice receiving the highest cell dose exhibited an engraftment plateau, in which the total number of engrafted human cells never exceeded the initial dose. These data suggest that donor cell expansion was inversely regulated by target niche parameters and/or transplantation density. Investigation of the response of donor cells to the host microenvironment should be a key variable in defining target cell dose in pre-clinical models of CNS disease and injury.

  15. MRI Evaluation of Spinal Length and Vertebral Body Angle During Loading with a Spinal Compression Harness

    Science.gov (United States)

    Campbell, James A.; Hargens, Alan R.; Murthy, G.; Ballard, R. E.; Watenpaugh, D. E.; Hargens, Alan, R.; Sanchez, E.; Yang, C.; Mitsui, I.; Schwandt, D.; hide

    1998-01-01

    Weight bearing by the spinal column during upright posture often plays a role in the common problem of low back pain. Therefore, we developed a non-ferromagnetic spinal compression harness to enable MRI investigations of the spinal column during axial loading. Human subjects were fitted with a Nest and a footplate which were connected by adjustable straps to an analog load cell. MRI scans of human subjects (5 males and 1 female with age range of 27-53 yrs) during loaded and unloaded conditions were accomplished with a 1.5 Tesla GE Signa scanner. Studies of two subjects undergoing sequentially increasing spinal loads revealed significant decreases (r(sup 2) = 0.852) in spinal length between T4 and L5 culminating in a 1.5 to 2% length decrease during loading with 75% body weight. Sagittal vertebral body angles of four subjects placed under a constant 50% body weight load for one hour demonstrated increased lordotic and kyphotic curvatures. In the lumbar spine, the L2 vertebral body experienced the greatest angular change (-3 deg. to -5 deg.) in most subjects while in the thoracic spine, T4 angles increased from the unloaded state by +2 deg. to +9 deg. Overall, our studies demonstrate: 1) a progressive, although surprisingly small, decrease in spinal length with increasing load and 2) relatively large changes in spinal column angulation with 50% body weight.

  16. Dynamic Pain Phenotypes are Associated with Spinal Cord Stimulation-Induced Reduction in Pain: A Repeated Measures Observational Pilot Study.

    Science.gov (United States)

    Campbell, Claudia M; Buenaver, Luis F; Raja, Srinivasa N; Kiley, Kasey B; Swedberg, Lauren J; Wacnik, Paul W; Cohen, Steven P; Erdek, Michael A; Williams, Kayode A; Christo, Paul J

    2015-07-01

    Spinal cord stimulation (SCS) has become a widely used treatment option for a variety of pain conditions. Substantial variability exists in the degree of benefit obtained from SCS and patient selection is a topic of expanding interest and importance. However, few studies have examined the potential benefits of dynamic quantitative sensory testing (QST) to develop objective measures of SCS outcomes or as a predictive tool to help patient selection. Psychological characteristics have been shown to play an important role in shaping individual differences in the pain experience and may aid in predicting responses to SCS. Static laboratory pain-induction measures have also been examined in their capacity for predicting SCS outcomes. The current study evaluated clinical, psychological and laboratory pain measures at baseline, during trial SCS lead placement, as well as 1 month and 3 months following permanent SCS implantation in chronic pain patients who received SCS treatment. Several QST measures were conducted, with specific focus on examination of dynamic models (central sensitization and conditioned pain modulation [CPM]) and their association with pain outcomes 3 months post SCS implantation. Results suggest few changes in QST over time. However, central sensitization and CPM at baseline were significantly associated with clinical pain at 3 months following SCS implantation, controlling for psycho/behavioral factors and pain at baseline. Specifically, enhanced central sensitization and reduced CPM were associated with less self-reported pain 3 months following SCS implantation. These findings suggest a potentially important role for dynamic pain assessment in individuals undergoing SCS, and hint at potential mechanisms through which SCS may impart its benefit. Wiley Periodicals, Inc.

  17. An electrically driven terahertz metamaterial diffractive modulator with more than 20 dB of dynamic range

    International Nuclear Information System (INIS)

    Karl, N.; Reichel, K.; Mendis, R.; Mittleman, D. M.; Chen, H.-T.; Taylor, A. J.; Brener, I.; Benz, A.; Reno, J. L.

    2014-01-01

    We design and experimentally demonstrate a switchable diffraction grating for terahertz modulation based on planar active metamaterials, where a Schottky gate structure is implemented to tune the metamaterial resonances in real-time via the application of an external voltage bias. The diffraction grating is formed by grouping the active split-ring resonators into an array of independent columns with alternate columns biased. We observe off-axis diffraction over a wide frequency band in contrast to the narrow-band resonances, which permits operation of the device as a relatively high-speed, wide-bandwidth, high-contrast modulator, with more than 20 dB of dynamic range

  18. Wide-Field Imaging Using Nitrogen Vacancies

    Science.gov (United States)

    Englund, Dirk Robert (Inventor); Trusheim, Matthew Edwin (Inventor)

    2017-01-01

    Nitrogen vacancies in bulk diamonds and nanodiamonds can be used to sense temperature, pressure, electromagnetic fields, and pH. Unfortunately, conventional sensing techniques use gated detection and confocal imaging, limiting the measurement sensitivity and precluding wide-field imaging. Conversely, the present sensing techniques do not require gated detection or confocal imaging and can therefore be used to image temperature, pressure, electromagnetic fields, and pH over wide fields of view. In some cases, wide-field imaging supports spatial localization of the NVs to precisions at or below the diffraction limit. Moreover, the measurement range can extend over extremely wide dynamic range at very high sensitivity.

  19. Cobalt catalyzed hydroesterification of a wide range of olefins

    Energy Technology Data Exchange (ETDEWEB)

    Van Rensburg, H.; Hanton, M.; Tooze, R.P.; Foster, D.F. [Sasol Technology UK, St Andrews (United Kingdom)

    2011-07-01

    Petrochemical raw materials are an essential raw material for the production of detergents with a substantial portion of synthetic fatty alcohols being produced via hydroformylation of oil or coal derived olefins. Carbonylation processes other than hydroformylation have to date not been commercially employed for the production of fatty esters or alcohols. In this document we highlight the opportunities of converting olefins to esters using cobalt catalyzed alkoxycarbonylation. This process is highly versatile and applicable to a wide range of olefins, linear or branched, alpha or internal in combination with virtually any chain length primary or secondary alcohol allowing the synthesis of a diverse array of compounds such as ester ethoxylated surfactants, methyl branched detergents, lubricants and alkyl propanoates. Furthermore, alkoxycarbonylation of a broad olefin/paraffin hydrocarbon range could be used to produce the corresponding broad cut detergent alcohols. (orig.)

  20. Preliminary assessment of the ecological risks to wide-ranging wildlife species on the Oak Ridge Reservation

    Energy Technology Data Exchange (ETDEWEB)

    Sample, B.E.; Baron, L.A.; Jackson, B.L.

    1995-08-01

    Historically, ecological risk assessment at CERCLA sites [such as the Oak Ridge Reservation (ORR)], has focused on species that may be definitively associated with a contaminated area or source operable unit. Consequently the species that are generally considered are those with home ranges small enough such that multiple individuals or a distinct population can be expected to reside within the boundaries of the contaminated site. This approach is adequate for sites with single, discrete areas of contamination that only provide habitat for species with limited requirements. This approach is not adequate however for large sites with multiple, spatially separated contaminated areas that provide habitat for wide-ranging wildlife species. Because wide-ranging wildlife species may travel between and use multiple contaminated sites they may be exposed to and be at risk from contaminants from multiple locations. Use of a particular contaminated site by wide-ranging species will be dependent upon the amount of suitable habitat available at that site. Therefore to adequately evaluate risks to wide-ranging species at the ORR-wide scale, the use of multiple contaminated sites must be weighted by the amount of suitable habitat on OUs. This reservation-wide ecological risk assessment is intended to identify which endpoints are significantly at risk; which contaminants are responsible for this risk; and which OUs significantly contribute to risk.

  1. Injury-induced ctgfa directs glial bridging and spinal cord regeneration in zebrafish

    Science.gov (United States)

    Mokalled, Mayssa H.; Patra, Chinmoy; Dickson, Amy L.; Endo, Toyokazu; Stainier, Didier Y. R.; Poss, Kenneth D.

    2016-01-01

    Unlike mammals, zebrafish efficiently regenerate functional nervous system tissue after major spinal cord injury. Whereas glial scarring presents a roadblock for mammalian spinal cord repair, glial cells in zebrafish form a bridge across severed spinal cord tissue and facilitate regeneration, a relatively unexplored process. Here, we performed a genome-wide profiling screen for secreted factors that are upregulated during zebrafish spinal cord regeneration. We find that connective tissue growth factor a (ctgfa) is induced in and around glial cells that participate in initial bridging events. Mutations in ctgfa disrupt spinal cord repair, while transgenic ctgfa overexpression and local human CTGF recombinant protein delivery accelerate bridging and functional regeneration. Our study reveals that CTGF is necessary and sufficient to stimulate glial bridging and natural spinal cord regeneration. PMID:27811277

  2. Human spinal locomotor control is based on flexibly organized burst generators.

    Science.gov (United States)

    Danner, Simon M; Hofstoetter, Ursula S; Freundl, Brigitta; Binder, Heinrich; Mayr, Winfried; Rattay, Frank; Minassian, Karen

    2015-03-01

    samples of rhythmic patterns. The basic activation patterns can be interpreted as central drives implemented by spinal burst generators that impose specific spatiotemporally organized activation on the lumbosacral motor neuron pools. Our data thus imply that the human lumbar spinal cord circuits can form burst-generating elements that flexibly combine to obtain a wide range of locomotor outputs from a constant, repetitive input. It may be possible to use this flexibility to incorporate specific adaptations to gait and stance to improve locomotor control, even after severe central nervous system damage. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. The risk associated with spinal manipulation

    DEFF Research Database (Denmark)

    Nielsen, Sabrina Mai; Tarp, Simon; Christensen, Robin

    2017-01-01

    BACKGROUND: Spinal manipulative therapy (SMT) is a widely used manual treatment, but many reviews exist with conflicting conclusions about the safety of SMT. We performed an overview of reviews to elucidate and quantify the risk of serious adverse events (SAEs) associated with SMT. METHODS: We...

  4. Long-Range Coulomb Effect in Intense Laser-Driven Photoelectron Dynamics.

    Science.gov (United States)

    Quan, Wei; Hao, XiaoLei; Chen, YongJu; Yu, ShaoGang; Xu, SongPo; Wang, YanLan; Sun, RenPing; Lai, XuanYang; Wu, ChengYin; Gong, QiHuang; He, XianTu; Liu, XiaoJun; Chen, Jing

    2016-06-03

    In strong field atomic physics community, long-range Coulomb interaction has for a long time been overlooked and its significant role in intense laser-driven photoelectron dynamics eluded experimental observations. Here we report an experimental investigation of the effect of long-range Coulomb potential on the dynamics of near-zero-momentum photoelectrons produced in photo-ionization process of noble gas atoms in intense midinfrared laser pulses. By exploring the dependence of photoelectron distributions near zero momentum on laser intensity and wavelength, we unambiguously demonstrate that the long-range tail of the Coulomb potential (i.e., up to several hundreds atomic units) plays an important role in determining the photoelectron dynamics after the pulse ends.

  5. Video Enhancement and Dynamic Range Control of HDR Sequences for Automotive Applications

    Directory of Open Access Journals (Sweden)

    Giovanni Ramponi

    2007-01-01

    Full Text Available CMOS video cameras with high dynamic range (HDR output are particularly suitable for driving assistance applications, where lighting conditions can strongly vary, going from direct sunlight to dark areas in tunnels. However, common visualization devices can only handle a low dynamic range, and thus a dynamic range reduction is needed. Many algorithms have been proposed in the literature to reduce the dynamic range of still pictures. Anyway, extending the available methods to video is not straightforward, due to the peculiar nature of video data. We propose an algorithm for both reducing the dynamic range of video sequences and enhancing its appearance, thus improving visual quality and reducing temporal artifacts. We also provide an optimized version of our algorithm for a viable hardware implementation on an FPGA. The feasibility of this implementation is demonstrated by means of a case study.

  6. An Optimized Control for LLC Resonant Converter with Wide Load Range

    Science.gov (United States)

    Xi, Xia; Qian, Qinsong

    2017-05-01

    This paper presents an optimized control which makes LLC resonant converters operate with a wider load range and provides good closed-loop performance. The proposed control employs two paralleled digital compensations to guarantee the good closed-loop performance in a wide load range during the steady state, an optimized trajectory control will take over to change the gate-driving signals immediately at the load transients. Finally, the proposed control has been implemented and tested on a 150W 200kHz 400V/24V LLC resonant converter and the result validates the proposed method.

  7. Spinal cord evolution in early Homo.

    Science.gov (United States)

    Meyer, Marc R; Haeusler, Martin

    2015-11-01

    The discovery at Nariokotome of the Homo erectus skeleton KNM-WT 15000, with a narrow spinal canal, seemed to show that this relatively large-brained hominin retained the primitive spinal cord size of African apes and that brain size expansion preceded postcranial neurological evolution. Here we compare the size and shape of the KNM-WT 15000 spinal canal with modern and fossil taxa including H. erectus from Dmanisi, Homo antecessor, the European middle Pleistocene hominins from Sima de los Huesos, and Pan troglodytes. In terms of shape and absolute and relative size of the spinal canal, we find all of the Dmanisi and most of the vertebrae of KNM-WT 15000 are within the human range of variation except for the C7, T2, and T3 of KNM-WT 15000, which are constricted, suggesting spinal stenosis. While additional fossils might definitively indicate whether H. erectus had evolved a human-like enlarged spinal canal, the evidence from the Dmanisi spinal canal and the unaffected levels of KNM-WT 15000 show that unlike Australopithecus, H. erectus had a spinal canal size and shape equivalent to that of modern humans. Subadult status is unlikely to affect our results, as spinal canal growth is complete in both individuals. We contest the notion that vertebrae yield information about respiratory control or language evolution, but suggest that, like H. antecessor and European middle Pleistocene hominins from Sima de los Huesos, early Homo possessed a postcranial neurological endowment roughly commensurate to modern humans, with implications for neurological, structural, and vascular improvements over Pan and Australopithecus. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Simultaneous wide-range stopping power determination for several ions

    Energy Technology Data Exchange (ETDEWEB)

    Alanko, T. E-mail: tommi.alanko@phys.jyu.fi; Trzaska, W.H.; Lyapin, V.; Raeisaenen, J.; Tiourine, G.; Virtanen, A

    2002-05-01

    A new procedure to extract simultaneously continuous stopping power curves for several ions and several absorbers over a wide energy range and with statistical errors reduced to negligible level is presented. The method combines our novel time-of-flight based method with the capability of our K130 cyclotron and ECR ion-source to produce the so-called ion cocktails. The potential of the method is demonstrated with a 6.0 MeV/u cocktail consisting of {sup 16}O{sup 4+}, {sup 28}Si{sup 7+} and {sup 40}Ar{sup 10+} ions. The stopping power in polycarbonate in the energy range of 0.35-5 MeV/u has been determined with absolute uncertainty of less than 2.3% and with relative below 0.2%. The results are compared with literature data and with SRIM2000 parameterisation including cores and bonds corrections.

  9. Age-related changes of the spinal cord: A biomechanical study.

    Science.gov (United States)

    Okazaki, Tomoya; Kanchiku, Tsukasa; Nishida, Norihiro; Ichihara, Kazuhiko; Sakuramoto, Itsuo; Ohgi, Junji; Funaba, Masahiro; Imajo, Yasuaki; Suzuki, Hidenori; Chen, Xian; Taguchi, Toshihiko

    2018-03-01

    Although it is known that aging plays an important role in the incidence and progression of cervical spondylotic myelopathy (CSM), the underlying mechanism is unclear. Studies that used fresh bovine cervical spinal cord report the gray matter of the cervical spinal cord as being more rigid and fragile than the white matter. However, there are no reports regarding the association between aging an tensile and Finite Element Method (FEM). Therefore, FEM was used based on the data pertaining to the mechanical features of older bovine cervical spinal cord to explain the pathogenesis of CSM in elderly patients. Tensile tests were conducted for white and gray matter separately in young and old bovine cervical spinal cords, and compared with their respective mechanical features. Based on the data obtained, FEM analysis was further performed, which included static and dynamic factors to describe the internal stress distribution changes of the spinal cord. These results demonstrated that the mechanical strength of young bovine spinal cords is different from that of old bovine spinal cords. The gray matter of the older spinal cord was significantly softer and more resistant to rupture compared with that of younger spinal cords (Pspinal cords in response to similar compression, when compared with young spinal cords. These results demonstrate that in analyzing the response of the spinal cord to compression, the age of patients is an important factor to be considered, in addition to the degree of compression, compression speed and parts of the spinal cord compression factor.

  10. Arteriovenous malformations of the cervical spinal cord

    International Nuclear Information System (INIS)

    Nagasawa, Shiro; Yoshida, Shinzo; Ishikawa, Masatsune; Yonekawa, Yasuhiro; Handa, Hajime

    1984-01-01

    Arteriovenous malformation (AVM) of the cervical spinal cord has been known to constitute 5-13% of all spinal AVMs. In contrast to the AVMs located in thoracic or thoraco-lumbar regions, cervical AVM has several characteristic features such as preponderance in younger generation, high incidence of subarachnoid hemorrhage, intramedullary location of the nidus usually fed by the anterior spinal arterial system. We reported three cases of cervical AVMs, which located intramedullary at the levels of C 4 -C 6 , C 1 -C 4 and C 1 -C 2 , respectively. Although selective angiography (vertebral artery, thyrocervical artery, costocervical artery) was essential for the diagnosis of these lesions, computerized tomographic (CT) study with both intrathecal injection of metrizamide and intravenous infusion of contrast material (dynamic and static study) was found to be extremely advantageous in detecting the topography of AVMs in the concerned horizontal planes of the spinal cord. Removal of AVM was given up in one case because of its possible involvement of the anterior spinal artery and central artery shown by CT scan. Removal of AVMs were performed in other two cases. A lateral approach was tried in one case with the AVM located in C 1 -C 2 level, in which CT scan revealed not only an intramedullary but the associated extramedullary AVM in ventrolateral surface of the spinal cord. This operative approach was found to involve less bone removal and markedly reduce spinal cord manipulation necessary to deal with ventrally situated high cervical lesions, compared with a posterior approach with laminectomy. (author)

  11. Factors associated with myelopathy in spinal tuberculosis

    International Nuclear Information System (INIS)

    Kitada, Yuki; Izawa, Kazutaka; Imoto, Kazuhiko; Yonenobu, Kazuo

    2009-01-01

    To identity factors associated with Pott's disease, 49 spinal tuberculosis patients were classified into a group of 22 patients with a neurological deficit and a group of 27 patients with no neurological deficits, and their clinical findings (gender, age, pulmonary tuberculosis, antituberculous chemotherapy, C reactive protein (CRP), nutritional status, and duration of disease) and radiographic findings (degree of canal encroachment, pathology and level of dural compression, number of affected vertebral bodies, range of paravertebral abscesses, signals in the spinal cord on MRI, kyphotic angle, and spinal instability) were compared. The results showed that malnutrition, severe canal encroachment, and abnormal signal within the spinal cord on MRI were associated with neurological complications. Factors associated with the degree of neurological deficit were unclear because the study population was too small. (author)

  12. Management of unstable spinal fractures with segmental spinal instrumentation (VSP System : Results at 5 year follow up

    Directory of Open Access Journals (Sweden)

    Sen Dipankar

    2005-01-01

    Full Text Available Background: Pedicle screw instrumentation has been widely used for spinal stabilisation following spinal injury with variable results. The controversial points associated with spinal injury are effects of canal compromise and decompression on neurological status. Methods: Thirty four patients of unstable thoraco-lumbar fracture with or without neuro-deficit were treated by decompression and stabilisation with VSP system and followed up for 22 - 39 months (mean 29 months. The results were evaluated by neurological recovery (ASIA score, pain relief, loss of surgical correction and functional rehabilitation (FIM score. Results: We achieved a mean post-operative correction of the kyphotic deformity by 14 degrees and an average gain of 30.2% in the canal diameter by decompression. However no correlation was established between degree of canal compromise before or after the surgery with the final neurological outcome. Conclusion: Although the infrastructure for spinal injury management in developing countries is inadequate in many aspects, we find that it is still possible to achieve results, which are comparable with standard literature by adequate decompression and stabilisation followed by appropriate rehabilitation according to the social and cultural demands of the patients.

  13. Range-wide assessment of livestock grazing across the sagebrush biome

    Science.gov (United States)

    Veblen, Kari E.; Pyke, David A.; Jones, Christopher A.; Casazza, Michael L.; Assal, Timothy J.; Farinha, Melissa A.

    2011-01-01

    Domestic livestock grazing occurs in virtually all sagebrush habitats and is a prominent disturbance factor. By affecting habitat condition and trend, grazing influences the resources required by, and thus, the distribution and abundance of sagebrush-obligate wildlife species (for example, sage-grouse Centrocercus spp.). Yet, the risks that livestock grazing may pose to these species and their habitats are not always clear. Although livestock grazing intensity and associated habitat condition may be known in many places at the local level, we have not yet been able to answer questions about use, condition, and trend at the landscape scale or at the range-wide scale for wildlife species. A great deal of information about grazing use, management regimes, and ecological condition exists at the local level (for individual livestock management units) under the oversight of organizations such as the Bureau of Land Management (BLM). However, the extent, quality, and types of existing data are unknown, which hinders the compilation, mapping, or analysis of these data. Once compiled, these data may be helpful for drawing conclusions about rangeland status, and we may be able to identify relationships between those data and wildlife habitat at the landscape scale. The overall objective of our study was to perform a range-wide assessment of livestock grazing effects (and the relevant supporting data) in sagebrush ecosystems managed by the BLM. Our assessments and analyses focused primarily on local-level management and data collected at the scale of BLM grazing allotments (that is, individual livestock management units). Specific objectives included the following: 1. Identify and refine existing range-wide datasets to be used for analyses of livestock grazing effects on sagebrush ecosystems. 2. Assess the extent, quality, and types of livestock grazing-related natural resource data collected by BLM range-wide (i.e., across allotments, districts and regions). 3. Compile and

  14. Changes in spinal mobility with increasing age in women.

    Science.gov (United States)

    Einkauf, D K; Gohdes, M L; Jensen, G M; Jewell, M J

    1987-03-01

    The purpose of our study was to determine changes in spinal mobility for women aged 20 to 84 years. Anterior flexion, right and left lateral flexion, and extension were measured on 109 healthy women. The modified Schober method was used to measure anterior flexion. Standard goniometry was used to measure lateral flexion and extension. The results of the study indicated that spinal mobility decreases with advancing age. The most significant (p less than .05) differences occurred between the two youngest and the two oldest age categories. Data gathered in this study indicate that physical therapists should consider the effects of age on spinal mobility when assessing spinal range of motion. A simple, objective method for measuring spinal mobility is presented. Suggestions for future research are given.

  15. Temporal components of the motor patterns expressed by the human spinal cord reflect foot kinematics.

    Science.gov (United States)

    Ivanenko, Yuri P; Grasso, Renato; Zago, Myrka; Molinari, Marco; Scivoletto, Giorgio; Castellano, Vincenzo; Macellari, Velio; Lacquaniti, Francesco

    2003-11-01

    What are the building blocks with which the human spinal cord constructs the motor patterns of locomotion? In principle, they could correspond to each individual activity pattern in dozens of different muscles. Alternatively, there could exist a small set of constituent temporal components that are common to all activation patterns and reflect global kinematic goals. To address this issue, we studied patients with spinal injury trained to step on a treadmill with body weight support. Patients learned to produce foot kinematics similar to that of healthy subjects but with activity patterns of individual muscles generally different from the control group. Hidden in the muscle patterns, we found a basic set of five temporal components, whose flexible combination accounted for the wide range of muscle patterns recorded in both controls and patients. Furthermore, two of the components were systematically related to foot kinematics across different stepping speeds and loading conditions. We suggest that the components are related to control signals output by spinal pattern generators, normally under the influence of descending and afferent inputs.

  16. Management of traumatic spinal column injury: A tertiary hospital experience

    Directory of Open Access Journals (Sweden)

    Md. Kamrul Ahsan

    2016-07-01

    Full Text Available Background: Trauma is the leading cause of disability in the first four decades of life and third most common cause of death. Spinal trauma poses considerable threats to survival and quality of life.Objective: Aims of this study is to assess the demographics, mode of trauma, hospital stay, complications, neurological improvement and mortality.Methods: Retrospective Cross sectional analysis of the records of spinal injury patients admitted in the Spine Unit of Bangabandhu Sheikh Mujib Medical University (BSMMU Hospital from October 2003 to December 2013 was carried out. The demo­graphics, mode of trauma, involved vertebral level, co-morbid factors; neurological status and its improvement by Ameri­can Spinal Injury Association (ASIA Score, duration of hospital stay and complications during hospital stay was assessed. Results were analyzed by SPSS.Results: Out of 1288 patients admitted, 192(14.90% patients(range, 8-72 years sustained spinal injuries and most (63.02%of them were young (range, 21-40 years. Male to female ratio was 5:1. Cervical spine was most commonly ( 44.66% affected followed by lumbar (35 .41 % , thoracic (13 .54% , thoraco-lumbar (06.25% and Cervico-thoracic (03.13% region. Fracture through intervertebral disc was most common in cervical spine. Among the common causes were road traffic accidents (44.47%, fall from height (29.69%, heavy weight bearing (14.58% and assault with gunshot (07.29%. Paraparesis was most frequent (51.05% clinical presentation followed by quadriparesis (45.83%. Significant number of patients (83.33% required operative treatment (p<0.05 and 09.89% were managed conservatively. Mortality rate (03.64% was insignificant (p>0.05% and 03.12% patient refused to take treatment. Of these patients, 77.01 % had shown neurological improvement of at least one grade according to ASIA Score.Conclusion: Wide varieties of patients are encountered and managed varying from conservative to surgery. Carefully selected

  17. Robust wide-range control of nuclear reactors by using the feedforward-feedback concept

    International Nuclear Information System (INIS)

    Weng, C.K.; Edwards, R.M.; Ray, A.

    1994-01-01

    A robust feedforward-feedback controller is proposed for wide-range operations of nuclear reactors. This control structure provides (a) optimized performance over a wide operating range resulting form the feedforward element and (b) guaranteed robust stability and performance resulting from the feedback element. The feedforward control law is synthesized via nonlinear programming, which generates an optimal control sequence over a finite-time horizon under specified constraints. The feedback control is synthesized via the structured singular value μ approach to guarantee robustness in the presence of disturbances and modeling uncertainties. The results of simulation experiments are presented to demonstrate efficacy of the proposed control structure for a large rapid power reduction to avoid unnecessary plant trips

  18. Diffusion tensor imaging of spinal cord parenchyma lesion in rat with chronic spinal cord injury.

    Science.gov (United States)

    Zhao, Can; Rao, Jia-Sheng; Pei, Xiao-Jiao; Lei, Jian-Feng; Wang, Zhan-Jing; Zhao, Wen; Wei, Rui-Han; Yang, Zhao-Yang; Li, Xiao-Guang

    2018-04-01

    Adequate evaluation of spinal cord parenchyma and accurate identification of injury range are considered two premises for the research and treatment of chronic spinal cord injury (SCI). Diffusion tensor imaging (DTI) provides information about water diffusion in spinal cord, and thus makes it possible to realize these premises. In this study, we conducted magnetic resonance imaging (MRI) for Wistar rats 84days after spinal cord contusion. DTI metrics including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) from different positions of the injured cord were collected, analyzed, and compared with the histological results and locomotor outcomes. Moreover, we performed fiber tractography, and examined the difference in cavity percentage obtained respectively via conventional MRI, DTI and histology. Results showed that the chronic SCI rats had the largest changes of all DTI metrics at the epicenter; the farther away from the epicenter, the smaller the variation. FA, AD and RD were all influenced by SCI in a greater space range than MD. The good consistency of FA values and histological results in specific regions evidenced FA's capability of reflecting Wallerian degeneration after SCI. DTI metrics at the epicenter in ventral funiculus also showed a close correlation with the BBB scores. Additionally, supported by the histological results, DTI enables a more accurate measurement of cavity percentage compared to the conventional MRI. DTI parameters might comprehensively reflect the post-SCI pathological status of spinal cord parenchyma at the epicenter and distal parts during the chronic stage, while showing good consistency with locomotor performance. DTI combined with tractography could intuitively display the distribution of spared fibers after SCI and accurately provide information such as cavity area. This may shed light on the research and treatment of chronic SCI. Copyright © 2017 Elsevier Inc. All rights

  19. Motor Integrated Permanent Magnet Gear with a Wide Torque-Speed Range

    DEFF Research Database (Denmark)

    Rasmussen, Peter Omand; Matzen, Torben N.; Jahns, T. M.

    2009-01-01

    This paper present a new motor integrated permanent magnet gear with a wide torque-speed range. In the paper a 35 kW permanent magnet motor with a base speed of 4000 rpm and a top speed of 14000 rpm is integrated into a permanent magnetic gear with a gearing ratio of 8.67. The design process...

  20. Entanglement Growth in Quench Dynamics with Variable Range Interactions

    Directory of Open Access Journals (Sweden)

    J. Schachenmayer

    2013-09-01

    Full Text Available Studying entanglement growth in quantum dynamics provides both insight into the underlying microscopic processes and information about the complexity of the quantum states, which is related to the efficiency of simulations on classical computers. Recently, experiments with trapped ions, polar molecules, and Rydberg excitations have provided new opportunities to observe dynamics with long-range interactions. We explore nonequilibrium coherent dynamics after a quantum quench in such systems, identifying qualitatively different behavior as the exponent of algebraically decaying spin-spin interactions in a transverse Ising chain is varied. Computing the buildup of bipartite entanglement as well as mutual information between distant spins, we identify linear growth of entanglement entropy corresponding to propagation of quasiparticles for shorter-range interactions, with the maximum rate of growth occurring when the Hamiltonian parameters match those for the quantum phase transition. Counterintuitively, the growth of bipartite entanglement for long-range interactions is only logarithmic for most regimes, i.e., substantially slower than for shorter-range interactions. Experiments with trapped ions allow for the realization of this system with a tunable interaction range, and we show that the different phenomena are robust for finite system sizes and in the presence of noise. These results can act as a direct guide for the generation of large-scale entanglement in such experiments, towards a regime where the entanglement growth can render existing classical simulations inefficient.

  1. A high dynamic range pulse counting detection system for mass spectrometry.

    Science.gov (United States)

    Collings, Bruce A; Dima, Martian D; Ivosev, Gordana; Zhong, Feng

    2014-01-30

    A high dynamic range pulse counting system has been developed that demonstrates an ability to operate at up to 2e8 counts per second (cps) on a triple quadrupole mass spectrometer. Previous pulse counting detection systems have typically been limited to about 1e7 cps at the upper end of the systems dynamic range. Modifications to the detection electronics and dead time correction algorithm are described in this paper. A high gain transimpedance amplifier is employed that allows a multi-channel electron multiplier to be operated at a significantly lower bias potential than in previous pulse counting systems. The system utilises a high-energy conversion dynode, a multi-channel electron multiplier, a high gain transimpedance amplifier, non-paralysing detection electronics and a modified dead time correction algorithm. Modification of the dead time correction algorithm is necessary due to a characteristic of the pulse counting electronics. A pulse counting detection system with the capability to count at ion arrival rates of up to 2e8 cps is described. This is shown to provide a linear dynamic range of nearly five orders of magnitude for a sample of aprazolam with concentrations ranging from 0.0006970 ng/mL to 3333 ng/mL while monitoring the m/z 309.1 → m/z 205.2 transition. This represents an upward extension of the detector's linear dynamic range of about two orders of magnitude. A new high dynamic range pulse counting system has been developed demonstrating the ability to operate at up to 2e8 cps on a triple quadrupole mass spectrometer. This provides an upward extension of the detector's linear dynamic range by about two orders of magnitude over previous pulse counting systems. Copyright © 2013 John Wiley & Sons, Ltd.

  2. Microbiome-wide association studies link dynamic microbial consortia to disease

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, Jack A.; Quinn, Robert A.; Debelius, Justine; Xu, Zhenjiang Z.; Morton, James; Garg, Neha; Jansson, Janet K.; Dorrestein, Pieter C.; Knight, Rob

    2016-07-06

    Rapid advances in DNA sequencing, metabolomics, proteomics and computational tools are dramatically increasing access to the microbiome and identification of its links with disease. In particular, time-series studies and multiple molecular perspectives are facilitating microbiome-wide association studies, which are analogous to genome-wide association studies. Early findings point to actionable outcomes of microbiome-wide association studies, although their clinical application has yet to be approved. An appreciation of the complexity of interactions among the microbiome and the host's diet, chemistry and health, as well as determining the frequency of observations that are needed to capture and integrate this dynamic interface, is paramount for developing precision diagnostics and therapies that are based on the microbiome.

  3. Evaluation of pre and post-operative spinal plain CT and CT-myelography

    International Nuclear Information System (INIS)

    Nagase, Joji; Inoue, Shunichi; Miyasaka, Hitoshi; Kamata, Sakae; Shinohara, Hiroyasu.

    1983-01-01

    Confirmation of the level of scan slices is essential for the CT diagnosis of spinal and spinal-cord diseases. Pre- and postoperative comparison should be made on the same level. For reading of plain CT and CTM, window levels should be identical pre- and postoperatively. Both methods demonstrated the spinal canal, morphology of the spinal cord, and three-Fdimensional pathologic pictures inside and outside the spinal cord. Preoperative CT contributed useful information on the pathologic conditions and selection of surgical procedures and routes. Postoperative plain CT confirmed surgical results, and CTM revealed the spinal cord and the subarachnoid space, as well as the range and degree of decompression from the spinal cord. (Chiba, N.)

  4. Characterization of advanced piezoelectric materials in the wide temperature range

    Energy Technology Data Exchange (ETDEWEB)

    Burianova, L.; Kopal, A.; Nosek, J

    2003-05-25

    We report about methods and results of our measurements of piezoelectric, dielectric and elastic properties of piezoelectric materials like crystals, ceramics, composites, polymers and thin layer composites. Among the methods, used in our laboratories are: the resonance method working in the temperature range 208-358 K, hydrostatic methods, both static and dynamic in the range 273-333 K, laser interferometric methods, using single and double-beam interferometer, working at room temperature, single and double-beam micro-interferometers, working inside of optical cryostat in the range 150-330 K, and pulse echo method for measurements of elastic coefficients, using ultrasonic set, working at room temperature. In our earlier papers we reported about some of our results of piezoelectric measurements of PZT ceramics using resonance method and laser interferometric method. The results of both methods were in good agreement. Now, the measurements are realized on 0-3 ceramic-polymer composites and thin layer composites. It is well known, that both intrinsic (material) and extrinsic (domain structure) contributions to properties of ferroelectric samples have characteristic, sometimes rather strong, temperature dependence. Therefore, any extension of temperature range of the above mentioned methods is welcomed.

  5. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    Energy Technology Data Exchange (ETDEWEB)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan, E-mail: lining@fudan.edu.c [State Key Laboratory of ASIC and System, Fudan University, Shanghai 201203 (China)

    2009-05-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 mum RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm{sup 2}. The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  6. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    International Nuclear Information System (INIS)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan

    2009-01-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 μm RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm 2 . The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  7. An ultrasensitive strain sensor with a wide strain range based on graphene armour scales.

    Science.gov (United States)

    Yang, Yi-Fan; Tao, Lu-Qi; Pang, Yu; Tian, He; Ju, Zhen-Yi; Wu, Xiao-Ming; Yang, Yi; Ren, Tian-Ling

    2018-06-12

    An ultrasensitive strain sensor with a wide strain range based on graphene armour scales is demonstrated in this paper. The sensor shows an ultra-high gauge factor (GF, up to 1054) and a wide strain range (ε = 26%), both of which present an advantage compared to most other flexible sensors. Moreover, the sensor is developed by a simple fabrication process. Due to the excellent performance, this strain sensor can meet the demands of subtle, large and complex human motion monitoring, which indicates its tremendous application potential in health monitoring, mechanical control, real-time motion monitoring and so on.

  8. Dual spinal lesion paradigm in the cat: evolution of the kinematic locomotor pattern.

    Science.gov (United States)

    Barrière, Grégory; Frigon, Alain; Leblond, Hugues; Provencher, Janyne; Rossignol, Serge

    2010-08-01

    The recovery of voluntary quadrupedal locomotion after an incomplete spinal cord injury can involve different levels of the CNS, including the spinal locomotor circuitry. The latter conclusion was reached using a dual spinal lesion paradigm in which a low thoracic partial spinal lesion is followed, several weeks later, by a complete spinal transection (i.e., spinalization). In this dual spinal lesion paradigm, cats can express hindlimb walking 1 day after spinalization, a process that normally takes several weeks, suggesting that the locomotor circuitry within the lumbosacral spinal cord had been modified after the partial lesion. Here we detail the evolution of the kinematic locomotor pattern throughout the dual spinal lesion paradigm in five cats to gain further insight into putative neurophysiological mechanisms involved in locomotor recovery after a partial spinal lesion. All cats recovered voluntary quadrupedal locomotion with treadmill training (3-5 days/wk) over several weeks. After the partial lesion, the locomotor pattern was characterized by several left/right asymmetries in various kinematic parameters, such as homolateral and homologous interlimb coupling, cycle duration, and swing/stance durations. When no further locomotor improvement was observed, cats were spinalized. After spinalization, the hindlimb locomotor pattern rapidly reappeared, but left/right asymmetries in swing/stance durations observed after the partial lesion could disappear or reverse. It is concluded that, after a partial spinal lesion, the hindlimb locomotor pattern was actively maintained by new dynamic interactions between spinal and supraspinal levels but also by intrinsic changes within the spinal cord.

  9. Development and regulation of response properties in spinal cord motoneurons

    DEFF Research Database (Denmark)

    Perrier, J F; Hounsgaard, J

    2000-01-01

    vertebrates in terms of both phylogeny and ontogeny. Spinal motoneurons in adults are remarkably similar in many respects ranging from the resting membrane potential to pacemaker properties. Apart from the axolotls, spinal motoneurons from all species investigated have latent intrinsic response properties...

  10. Ozone formation in pulsed SDBD in a wide pressure range

    Science.gov (United States)

    Starikovskiy, Andrey; Nudnova, Maryia; mipt Team

    2011-10-01

    Ozone concentration in surface anode-directed DBD for wide pressure range (150 - 1300 torr) was experimentally measured. Voltage and pressure effect were investigated. Reduced electric field was measured for anode-directed and cathode-directed SDBD. E/n values in cathode-directed SDBD is higher than in cathode-directed on 50 percent at atmospheric pressure. E/n value increase leads to decrease the rate of oxygen dissociation and Ozone formation at lower pressures. Radiating region thickness of sliding discharge was measured. Typical thickness of radiating zone is 0.4-1.0 mm within pressure range 220-740 torr. It was shown that high-voltage pulsed nanosecond discharge due to high E/n value produces less Ozone with compare to other discharges. Kinetic model was proposed to describe Ozone formation in the pulsed nanosecond SDBD.

  11. High dynamic range imaging sensors and architectures

    CERN Document Server

    Darmont, Arnaud

    2013-01-01

    Illumination is a crucial element in many applications, matching the luminance of the scene with the operational range of a camera. When luminance cannot be adequately controlled, a high dynamic range (HDR) imaging system may be necessary. These systems are being increasingly used in automotive on-board systems, road traffic monitoring, and other industrial, security, and military applications. This book provides readers with an intermediate discussion of HDR image sensors and techniques for industrial and non-industrial applications. It describes various sensor and pixel architectures capable

  12. Subdural Thoracolumbar Spine Hematoma after Spinal Anesthesia: A Rare Occurrence and Literature Review of Spinal Hematomas after Spinal Anesthesia.

    Science.gov (United States)

    Maddali, Prasanthi; Walker, Blake; Fisahn, Christian; Page, Jeni; Diaz, Vicki; Zwillman, Michael E; Oskouian, Rod J; Tubbs, R Shane; Moisi, Marc

    2017-02-16

    Spinal hematomas are a rare but serious complication of spinal epidural anesthesia and are typically seen in the epidural space; however, they have been documented in the subdural space. Spinal subdural hematomas likely exist within a traumatically induced space within the dural border cell layer, rather than an anatomical subdural space. Spinal subdural hematomas present a dangerous clinical situation as they have the potential to cause significant compression of neural elements and can be easily mistaken for spinal epidural hematomas. Ultrasound can be an effective modality to diagnose subdural hematoma when no epidural blood is visualized. We have reviewed the literature and present a full literature review and a case presentation of an 82-year-old male who developed a thoracolumbar spinal subdural hematoma after spinal epidural anesthesia. Anticoagulant therapy is an important predisposing risk factor for spinal epidural hematomas and likely also predispose to spinal subdural hematomas. It is important to consider spinal subdural hematomas in addition to spinal epidural hematomas in patients who develop weakness after spinal epidural anesthesia, especially in patients who have received anticoagulation.

  13. Image-guided robotic radiosurgery for spinal metastases

    International Nuclear Information System (INIS)

    Gibbs, Iris C.; Kamnerdsupaphon, Pimkhuan; Ryu, Mi-Ryeong; Dodd, Robert; Kiernan, Michaela; Chang, Steven D.; Adler, John R.

    2007-01-01

    Background and Purpose: To determine the effectiveness and safety of image-guided robotic radiosurgery for spinal metastases. Materials/Methods: From 1996 to 2005, 74 patients with 102 spinal metastases were treated using the CyberKnife TM at Stanford University. Sixty-two (84%) patients were symptomatic. Seventy-four percent (50/68) of previously treated patients had prior radiation. Using the CyberKnife TM , 16-25 Gy in 1-5 fractions was delivered. Patients were followed clinically and radiographically for at least 3 months or until death. Results: With mean follow-up of 9 months (range 0-33 months), 36 patients were alive and 38 were dead at last follow-up. No death was treatment related. Eighty-four (84%) percent of symptomatic patients experienced improvement or resolution of symptoms after treatment. Three patients developed treatment-related spinal injury. Analysis of dose-volume parameters and clinical parameters failed to identify predictors of spinal cord injury. Conclusions: Robotic radiosurgery is effective and generally safe for spinal metastases even in previously irradiated patients

  14. Wearable Wide-Range Strain Sensors Based on Ionic Liquids and Monitoring of Human Activities

    Directory of Open Access Journals (Sweden)

    Shao-Hui Zhang

    2017-11-01

    Full Text Available Wearable sensors for detection of human activities have encouraged the development of highly elastic sensors. In particular, to capture subtle and large-scale body motion, stretchable and wide-range strain sensors are highly desired, but still a challenge. Herein, a highly stretchable and transparent stain sensor based on ionic liquids and elastic polymer has been developed. The as-obtained sensor exhibits impressive stretchability with wide-range strain (from 0.1% to 400%, good bending properties and high sensitivity, whose gauge factor can reach 7.9. Importantly, the sensors show excellent biological compatibility and succeed in monitoring the diverse human activities ranging from the complex large-scale multidimensional motions to subtle signals, including wrist, finger and elbow joint bending, finger touch, breath, speech, swallow behavior and pulse wave.

  15. Spinal cord contusion.

    Science.gov (United States)

    Ju, Gong; Wang, Jian; Wang, Yazhou; Zhao, Xianghui

    2014-04-15

    Spinal cord injury is a major cause of disability with devastating neurological outcomes and limited therapeutic opportunities, even though there are thousands of publications on spinal cord injury annually. There are two major types of spinal cord injury, transaction of the spinal cord and spinal cord contusion. Both can theoretically be treated, but there is no well documented treatment in human being. As for spinal cord contusion, we have developed an operation with fabulous result.

  16. Transport properties of gaseous ions over a wide energy range, IV

    International Nuclear Information System (INIS)

    Viehland, L.A.; Mason, E.A.

    1995-01-01

    This paper updates three previous papers entitled open-quotes Transport Properties of Gaseous Ions over a Wide Energy Range.close quotes. These papers referred to as Parts I, II, and III, were by H.W.Ellis, P.Y. Pai, E.W. McDaniel, E.A. Mason, and L.A. Viehland, S.L. Lin, M.G. Thackston. Part IV contains compilations of experimental data on ionic mobilities and diffusion coefficients (both longitudinal and transverse) for ions in neutral gases in an externally applied electrostatic field, at various gas temperatures; the data are tabulated as a function of the ionic energy parameter E/N, where E is the electric field strength and N is the number density of the neutral gas. Part IV also contains a locator key to ionic mobilities and diffusion coefficients compiled in Parts I-IV. The coverage of the literature extends into 1994. The criteria for selection of the data are; (1) the measurements must cover a reasonably wide range of E/N; (2) the identity of the ions must be well established; and (3) the accuracy of the data must be good. 26 refs., 6 tabs

  17. Can the human lumbar posterior columns be stimulated by transcutaneous spinal cord stimulation? A modeling study

    OpenAIRE

    Danner, Simon M.; Hofstoetter, Ursula S.; Ladenbauer, Josef; Rattay, Frank; Minassian, Karen

    2011-01-01

    Stimulation of different spinal cord segments in humans is a widely developed clinical practice for modification of pain, altered sensation and movement. The human lumbar cord has become a target for modification of motor control by epidural and more recently by transcutaneous spinal cord stimulation. Posterior columns of the lumbar spinal cord represent a vertical system of axons and when activated can add other inputs to the motor control of the spinal cord than stimulated posterior roots. ...

  18. Genetically encoded ratiometric fluorescent thermometer with wide range and rapid response.

    Directory of Open Access Journals (Sweden)

    Masahiro Nakano

    Full Text Available Temperature is a fundamental physical parameter that plays an important role in biological reactions and events. Although thermometers developed previously have been used to investigate several important phenomena, such as heterogeneous temperature distribution in a single living cell and heat generation in mitochondria, the development of a thermometer with a sensitivity over a wide temperature range and rapid response is still desired to quantify temperature change in not only homeotherms but also poikilotherms from the cellular level to in vivo. To overcome the weaknesses of the conventional thermometers, such as a limitation of applicable species and a low temporal resolution, owing to the narrow temperature range of sensitivity and the thermometry method, respectively, we developed a genetically encoded ratiometric fluorescent temperature indicator, gTEMP, by using two fluorescent proteins with different temperature sensitivities. Our thermometric method enabled a fast tracking of the temperature change with a time resolution of 50 ms. We used this method to observe the spatiotemporal temperature change between the cytoplasm and nucleus in cells, and quantified thermogenesis from the mitochondria matrix in a single living cell after stimulation with carbonyl cyanide 4-(trifluoromethoxyphenylhydrazone, which was an uncoupler of oxidative phosphorylation. Moreover, exploiting the wide temperature range of sensitivity from 5°C to 50°C of gTEMP, we monitored the temperature in a living medaka embryo for 15 hours and showed the feasibility of in vivo thermometry in various living species.

  19. Radiographic Predictors for Mechanical Failure After Adult Spinal Deformity Surgery

    DEFF Research Database (Denmark)

    Hallager, Dennis W; Karstensen, Sven; Bukhari, Naeem

    2017-01-01

    spinal deformity surgery range 12% to 37% in literature. Although the importance of spinal and spino-pelvic alignment is well documented for surgical outcome and ideal alignment has been proposed as sagittal vertical axis (SVA) lordosis (LL) = pelvic incidence ± 9...

  20. Potent spinal parenchymal AAV9-mediated gene delivery by subpial injection in adult rats and pigs

    Directory of Open Access Journals (Sweden)

    Atsushi Miyanohara

    2016-01-01

    Full Text Available Effective in vivo use of adeno-associated virus (AAV-based vectors to achieve gene-specific silencing or upregulation in the central nervous system has been limited by the inability to provide more than limited deep parenchymal expression in adult animals using delivery routes with the most clinical relevance (intravenous or intrathecal. Here, we demonstrate that the spinal pia membrane represents the primary barrier limiting effective AAV9 penetration into the spinal parenchyma after intrathecal AAV9 delivery. We develop a novel subpial AAV9 delivery technique and AAV9-dextran formulation. We use these in adult rats and pigs to show (i potent spinal parenchymal transgene expression in white and gray matter including neurons, glial and endothelial cells after single bolus subpial AAV9 delivery; (ii delivery to almost all apparent descending motor axons throughout the length of the spinal cord after cervical or thoracic subpial AAV9 injection; (iii potent retrograde transgene expression in brain motor centers (motor cortex and brain stem; and (iv the relative safety of this approach by defining normal neurological function for up to 6 months after AAV9 delivery. Thus, subpial delivery of AAV9 enables gene-based therapies with a wide range of potential experimental and clinical utilizations in adult animals and human patients.

  1. MRI and neurological findings in patients with spinal metastases

    International Nuclear Information System (INIS)

    Switlyk, M.D.; Hole, K.H.; Knutstad, K.; Skjeldal, S.; Zaikova, O.; Hald, J.K.; Seierstad, T.

    2012-01-01

    Background. Magnetic resonance imaging (MRI) is the recommended primary investigation method for metastatic spinal cord compression (MSCC). Initiating treatment before the development of motor deficits is essential to preserve neurological function. However, the relationship between MRI-assessed grades of spinal metastatic disease and neurological status has not been widely investigated. Purpose. To analyze the association between neurological function and MRI-based assessment of the extent of spinal metastases using two different grading systems. Material and Methods. A total of 284 patients admitted to our institution for initial radiotherapy or surgery for symptomatic spinal metastases were included in the study. Motor and sensory deficits were categorized according to the Frankel classification system. Pre-treatment MRI evaluations of the entire spine were scored for the extent of spinal metastases, presence and severity of spinal cord compression, and nerve root compression. Two MRI-based scales were used to evaluate the degree of cord compression and spinal canal narrowing and relate these findings to neurological function. Results. Of the patients included in the study, 28 were non-ambulatory, 49 were ambulatory with minor motor deficits, and 207 had normal motor function. Spinal cord compression was present in all patients with Frankel scores of B or C, 23 of 35 patients with a Frankel score of D (66%), and 48 of 152 patients with a Frankel score of E (32%). The percentage of patients with severe spinal canal narrowing increased with increasing Frankel grades. The grading according to the scales showed a significant association with the symptoms according to the Frankel scale (P < 0.001). Conclusion. In patients with neurological dysfunction, the presence and severity of impairment was associated with the epidural tumor burden. A significant number of patients had radiological spinal cord compression and normal motor function (occult MSCC)

  2. Nuclear magnetic imaging for MTRA. Spinal canal and spinal cord

    International Nuclear Information System (INIS)

    Fritzsch, Dominik; Hoffmann, Karl-Titus

    2011-01-01

    The booklet covers the following topics: (1) Clinical indications for NMR imaging of spinal cord and spinal canal; (2) Methodic requirements: magnets and coils, image processing, contrast media: (3) Examination technology: examination conditions, sequences, examination protocols; (4) Disease pattern and indications: diseases of the myelin, the spinal nerves and the spinal canal (infections, tumors, injuries, ischemia and bleedings, malformations); diseases of the spinal cord and the intervertebral disks (degenerative changes, infections, injuries, tumors, malformations).

  3. Regulation of Cortical Dynamic Range by Background Synaptic Noise and Feedforward Inhibition.

    Science.gov (United States)

    Khubieh, Ayah; Ratté, Stéphanie; Lankarany, Milad; Prescott, Steven A

    2016-08-01

    The cortex encodes a broad range of inputs. This breadth of operation requires sensitivity to weak inputs yet non-saturating responses to strong inputs. If individual pyramidal neurons were to have a narrow dynamic range, as previously claimed, then staggered all-or-none recruitment of those neurons would be necessary for the population to achieve a broad dynamic range. Contrary to this explanation, we show here through dynamic clamp experiments in vitro and computer simulations that pyramidal neurons have a broad dynamic range under the noisy conditions that exist in the intact brain due to background synaptic input. Feedforward inhibition capitalizes on those noise effects to control neuronal gain and thereby regulates the population dynamic range. Importantly, noise allows neurons to be recruited gradually and occludes the staggered recruitment previously attributed to heterogeneous excitation. Feedforward inhibition protects spike timing against the disruptive effects of noise, meaning noise can enable the gain control required for rate coding without compromising the precise spike timing required for temporal coding. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  4. Decreased spinal synaptic inputs to phrenic motor neurons elicit localized inactivity-induced phrenic motor facilitation

    Science.gov (United States)

    Streeter, K.A.; Baker-Herman, T.L.

    2014-01-01

    Phrenic motor neurons receive rhythmic synaptic inputs throughout life. Since even brief disruption in phrenic neural activity is detrimental to life, on-going neural activity may play a key role in shaping phrenic motor output. To test the hypothesis that spinal mechanisms sense and respond to reduced phrenic activity, anesthetized, ventilated rats received micro-injections of procaine in the C2 ventrolateral funiculus (VLF) to transiently (~30 min) block axon conduction in bulbospinal axons from medullary respiratory neurons that innervate one phrenic motor pool; during procaine injections, contralateral phrenic neural activity was maintained. Once axon conduction resumed, a prolonged increase in phrenic burst amplitude was observed in the ipsilateral phrenic nerve, demonstrating inactivity-induced phrenic motor facilitation (iPMF). Inhibition of tumor necrosis factor alpha (TNFα) and atypical PKC (aPKC) activity in spinal segments containing the phrenic motor nucleus impaired ipsilateral iPMF, suggesting a key role for spinal TNFα and aPKC in iPMF following unilateral axon conduction block. A small phrenic burst amplitude facilitation was also observed contralateral to axon conduction block, indicating crossed spinal phrenic motor facilitation (csPMF). csPMF was independent of spinal TNFα and aPKC. Ipsilateral iPMF and csPMF following unilateral withdrawal of phrenic synaptic inputs were associated with proportional increases in phrenic responses to chemoreceptor stimulation (hypercapnia), suggesting iPMF and csPMF increase phrenic dynamic range. These data suggest that local, spinal mechanisms sense and respond to reduced synaptic inputs to phrenic motor neurons. We hypothesize that iPMF and csPMF may represent compensatory mechanisms that assure adequate motor output is maintained in a physiological system in which prolonged inactivity ends life. PMID:24681155

  5. Using dogs to find cats: detection dogs as a survey method for wide-ranging cheetah

    OpenAIRE

    Becker, M. S.; Durant, S. M.; Watson, F. G. R.; Parker, M.; Gottelli, D.; M Soka, J.; Droge, E.; Nyirenda, M.; Schuette, P.; Dunkley, P.; Brummer, R.

    2017-01-01

    Rapid global large carnivore declines make evaluations of remaining populations critical. Yet landscape-scale evaluations of presence, abundance and distribution are difficult, as many species are wide-ranging, occur only at low densities and are elusive. Insufficient information-gathering tools for many large carnivore species compounds these challenges. Specially trained detection dogs have demonstrated effectiveness for carnivore surveys, but are untested on extremely sparse, wide-ranging ...

  6. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Spinal Cord Injury Facts and Figures Care and Treatment After SCI Spinal Cord Injury Rehabilitation Pediatric Spinal ... Spinal Cord Injury Facts and Figures Care and Treatment After SCI Spinal Cord Injury Rehabilitation Pediatric Spinal ...

  7. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Animated Spinal Cord Injury Chart Spinal Cord Injury Facts and Figures Care and Treatment After SCI Spinal ... Animated Spinal Cord Injury Chart Spinal Cord Injury Facts and Figures Care and Treatment After SCI Spinal ...

  8. Boost Half-Bridge DC-DC Converter with Reconfigurable Rectifier for Ultra-Wide Input Voltage Range Applications

    DEFF Research Database (Denmark)

    Vinnikov, Dmitri; Chub, Andrii; Liivik, Elizaveta

    2018-01-01

    This paper introduces a novel galvanically isolated boost half-bridge dc-dc converter intended for modern power electronic applications where ultra-wide input voltage regulation range is needed. A reconfigurable output rectifier stage performs a transition between the voltage doubler and the full......-bridge diode rectifiers and, by this means, extends the regulation range significantly. The converter features a low number of components and resonant soft switching of semiconductors, which result in high power conversion efficiency over a wide input voltage and load range. The paper presents the operating...

  9. Wide-range stiffness gradient PVA/HA hydrogel to investigate stem cell differentiation behavior.

    Science.gov (United States)

    Oh, Se Heang; An, Dan Bi; Kim, Tae Ho; Lee, Jin Ho

    2016-04-15

    Although stiffness-controllable substrates have been developed to investigate the effect of stiffness on cell behavior and function, the use of separate substrates with different degrees of stiffness, substrates with a narrow range stiffness gradient, toxicity of residues, different surface composition, complex fabrication procedures/devices, and low cell adhesion are still considered as hurdles of conventional techniques. In this study, a cylindrical polyvinyl alcohol (PVA)/hyaluronic acid (HA) hydrogel with a wide-range stiffness gradient (between ∼20kPa and ∼200kPa) and cell adhesiveness was prepared by a liquid nitrogen (LN2)-contacting gradual freezing-thawing method that does not use any additives or specific devices to produce the stiffness gradient hydrogel. From an in vitro cell culture using the stiffness gradient PVA/HA hydrogel, it was observed that human bone marrow mesenchymal stem cells have favorable stiffness ranges for induction of differentiation into specific cell types (∼20kPa for nerve cell, ∼40kPa for muscle cell, ∼80kPa for chondrocyte, and ∼190kPa for osteoblast). The PVA/HA hydrogel with a wide range of stiffness spectrum can be a useful tool for basic studies related with the stem cell differentiation, cell reprogramming, cell migration, and tissue regeneration in terms of substrate stiffness. It is postulated that the stiffness of the extracellular matrix influences cell behavior. To prove this concept, various techniques to prepare substrates with a stiffness gradient have been developed. However, the narrow ranges of stiffness gradient and complex fabrication procedures/devices are still remained as limitations. Herein, we develop a substrate (hydrogel) with a wide-range stiffness gradient using a gradual freezing-thawing method which does not need specific devices to produce a stiffness gradient hydrogel. From cell culture experiments using the hydrogel, it is observed that human bone marrow mesenchymal stem cells have

  10. Microbiome-wide association studies link dynamic microbial consortia to disease

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, Jack A.; Quinn, Robert A.; Debelius, Justine; Xu, Zhenjiang Z.; Morton, James; Garg, Neha; Jansson, Janet K.; Dorrestein, Pieter C.; Knight, Rob

    2016-07-06

    Rapid advances in DNA sequencing, metabolomics, proteomics and computation dramatically increase accessibility of microbiome studies and identify links between the microbiome and disease. Microbial time-series and multiple molecular perspectives enable Microbiome-Wide Association Studies (MWAS), analogous to Genome-Wide Association Studies (GWAS). Rapid research advances point towards actionable results, although approved clinical tests based on MWAS are still in the future. Appreciating the complexity of interactions between diet, chemistry, health and the microbiome, and determining the frequency of observations needed to capture and integrate this dynamic interface, is paramount for addressing the need for personalized and precision microbiome-based diagnostics and therapies.

  11. Stereotactic Body Radiation Therapy in Spinal Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Kamran A. [Mayo Medical School, College of Medicine, Mayo Clinic, Rochester, MN (United States); Stauder, Michael C.; Miller, Robert C.; Bauer, Heather J. [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States); Rose, Peter S. [Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN (United States); Olivier, Kenneth R. [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States); Brown, Paul D. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Brinkmann, Debra H. [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States); Laack, Nadia N., E-mail: laack.nadia@mayo.edu [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States)

    2012-04-01

    Purpose: Based on reports of safety and efficacy, stereotactic body radiotherapy (SBRT) for treatment of malignant spinal tumors was initiated at our institution. We report prospective results of this population at Mayo Clinic. Materials and Methods: Between April 2008 and December 2010, 85 lesions in 66 patients were treated with SBRT for spinal metastases. Twenty-two lesions (25.8%) were treated for recurrence after prior radiotherapy (RT). The mean age of patients was 56.8 {+-} 13.4 years. Patients were treated to a median dose of 24 Gy (range, 10-40 Gy) in a median of three fractions (range, 1-5). Radiation was delivered with intensity-modulated radiotherapy (IMRT) and prescribed to cover 80% of the planning target volume (PTV) with organs at risk such as the spinal cord taking priority over PTV coverage. Results: Tumor sites included 48, 22, 12, and 3 in the thoracic, lumbar, cervical, and sacral spine, respectively. The mean actuarial survival at 12 months was 52.2%. A total of 7 patients had both local and marginal failure, 1 patient experienced marginal but not local failure, and 1 patient had local failure only. Actuarial local control at 1 year was 83.3% and 91.2% in patients with and without prior RT. The median dose delivered to patients who experienced local/marginal failure was 24 Gy (range, 18-30 Gy) in a median of three fractions (range, 1-5). No cases of Grade 4 toxicity were reported. In 1 of 2 patients experiencing Grade 3 toxicity, SBRT was given after previous radiation. Conclusion: The results indicate SBRT to be an effective measure to achieve local control in spinal metastases. Toxicity of treatment was rare, including those previously irradiated. Our results appear comparable to previous reports analyzing spine SBRT. Further research is needed to determine optimum dose and fractionation to further improve local control and prevent toxicity.

  12. Darwin: Dose monitoring system applicable to various radiations with wide energy ranges

    International Nuclear Information System (INIS)

    Sato, T.; Satoh, D.; Endo, A.; Yamaguchi, Y.

    2007-01-01

    A new radiation dose monitor, designated as DARWIN (Dose monitoring system Applicable to various Radiations with Wide energy ranges), has been developed for real-time monitoring of doses in workspaces and surrounding environments of high-energy accelerator facilities. DARWIN is composed of a Phoswitch-type scintillation detector, which consists of liquid organic scintillator BC501A coupled with ZnS(Ag) scintillation sheets doped with 6 Li, and a data acquisition system based on a Digital-Storage-Oscilloscope. DARWIN has the following features: (1) capable of monitoring doses from neutrons, photons and muons with energies from thermal energy to 1 GeV, 150 keV to 100 MeV and 1 MeV to 100 GeV, respectively, (2) highly sensitive with precision and (3) easy to operate with a simple graphical user-interface. The performance of DARWIN was examined experimentally in several radiation fields. The results of the experiments indicated the accuracy and wide response range of DARWIN for measuring dose rates from neutrons, photons and muons with wide energies. It was also found from the experiments that DARWIN enables us to monitor small fluctuations of neutron dose rates near the background level because of its high sensitivity. With these properties, DARWIN will be able to play a very important role for improving radiation safety in high-energy accelerator facilities. (authors)

  13. [Neuronal control of posture and locomotion in decerebrated and spinalized animals].

    Science.gov (United States)

    Musienko, P E; Gorskiĭ, O V; Kilimnik, V A; Kozlovskaia, I B; Courtine, G; Edgerton, V R; Gerasimenko, Iu P

    2013-03-01

    We have found that the brainstem-spinal cord circuitry of decerebrated cats actively maintain the equilibrium during standing, walking and imposed mechanical perturbations similar to that observed in intact animals. The corrective hindlimb motor responses during standing included redistribution of the extensor activity ipsilateral and contralateral to perturbation. The postural corrections in walking cats were due to considerable modification of EMG pattern in the limbs as well as changing of the swing-stance phases of the step cycle and ground reaction forces depending of perturbation side. Thus the basic mechanisms for balance control of decerebrated animals in these two forms of motor behavior are different. Balance-related adjustments relied entirely on the integration of somatosensory information arising from the moving hindquarters because of the suppression of vestibular, visual, and head-neck-trunk sensory input. We propose that the somatosensory input from the hindquarters in concert with the lumbosacral spinal circuitry can control the dynamics of the hindquarters sufficient to sustain balance. We found that, after isolation from the brainstem or forebrain, lumbosacral circuits receiving tonic epidural electrical stimulation can effectively control equilibrium during standing and stepping. Detailed analyses of the relationships among muscle activity, trunk kinematics, and limb kinetics indicate that spinal motor systems utilize a combination of feedback and feedforward strategies to maintain dynamic equilibrium during walking. The unexpected ability of spinal circuitries to exert efficient postural control in the presence of epidural electrical stimulation in decerebrated and spinal cats have significant implications for the potential of humans with a severe spinal cord injury to regain a significant level of functional standing and walking capacities.

  14. Anatomical Recruitment of Spinal V2a Interneurons into Phrenic Motor Circuitry after High Cervical Spinal Cord Injury.

    Science.gov (United States)

    Zholudeva, Lyandysha V; Karliner, Jordyn S; Dougherty, Kimberly J; Lane, Michael A

    2017-11-01

    More than half of all spinal cord injuries (SCIs) occur at the cervical level, often resulting in impaired respiration. Despite this devastating outcome, there is substantial evidence for endogenous neuroplasticity after cervical SCI. Spinal interneurons are widely recognized as being an essential anatomical component of this plasticity by contributing to novel neuronal pathways that can result in functional improvement. The identity of spinal interneurons involved with respiratory plasticity post-SCI, however, has remained largely unknown. Using a transgenic Chx10-eGFP mouse line (Strain 011391-UCD), the present study is the first to demonstrate the recruitment of excitatory interneurons into injured phrenic circuitry after a high cervical SCI. Diaphragm electromyography and anatomical analysis were used to confirm lesion-induced functional deficits and document extent of the lesion, respectively. Transneuronal tracing with pseudorabies virus (PRV) was used to identify interneurons within the phrenic circuitry. There was a robust increase in the number of PRV-labeled V2a interneurons ipsilateral to the C2 hemisection, demonstrating that significant numbers of these excitatory spinal interneurons were anatomically recruited into the phrenic motor pathway two weeks after injury, a time known to correspond with functional phrenic plasticity. Understanding this anatomical spinal plasticity and the neural substrates associated with functional compensation or recovery post-SCI in a controlled, experimental setting may help shed light onto possible cellular therapeutic candidates that can be targeted to enhance spontaneous recovery.

  15. Does inter-vertebral range of motion increase after spinal manipulation? A prospective cohort study.

    Science.gov (United States)

    Branney, Jonathan; Breen, Alan C

    2014-01-01

    Spinal manipulation for nonspecific neck pain is thought to work in part by improving inter-vertebral range of motion (IV-RoM), but it is difficult to measure this or determine whether it is related to clinical outcomes. This study undertook to determine whether cervical spine flexion and extension IV-RoM increases after a course of spinal manipulation, to explore relationships between any IV-RoM increases and clinical outcomes and to compare palpation with objective measurement in the detection of hypo-mobile segments. Thirty patients with nonspecific neck pain and 30 healthy controls matched for age and gender received quantitative fluoroscopy (QF) screenings to measure flexion and extension IV-RoM (C1-C6) at baseline and 4-week follow-up between September 2012-13. Patients received up to 12 neck manipulations and completed NRS, NDI and Euroqol 5D-5L at baseline, plus PGIC and satisfaction questionnaires at follow-up. IV-RoM accuracy, repeatability and hypo-mobility cut-offs were determined. Minimal detectable changes (MDC) over 4 weeks were calculated from controls. Patients and control IV-RoMs were compared at baseline as well as changes in patients over 4 weeks. Correlations between outcomes and the number of manipulations received and the agreement (Kappa) between palpated and QF-detected of hypo-mobile segments were calculated. QF had high accuracy (worst RMS error 0.5o) and repeatability (highest SEM 1.1o, lowest ICC 0.90) for IV-RoM measurement. Hypo-mobility cut offs ranged from 0.8o to 3.5o. No outcome was significantly correlated with increased IV-RoM above MDC and there was no significant difference between the number of hypo-mobile segments in patients and controls at baseline or significant increases in IV-RoMs in patients. However, there was a modest and significant correlation between the number of manipulations received and the number of levels and directions whose IV-RoM increased beyond MDC (Rho=0.39, p=0.043). There was also no agreement

  16. A High-Dynamic-Range Optical Remote Sensing Imaging Method for Digital TDI CMOS

    Directory of Open Access Journals (Sweden)

    Taiji Lan

    2017-10-01

    Full Text Available The digital time delay integration (digital TDI technology of the complementary metal-oxide-semiconductor (CMOS image sensor has been widely adopted and developed in the optical remote sensing field. However, the details of targets that have low illumination or low contrast in scenarios of high contrast are often drowned out because of the superposition of multi-stage images in digital domain multiplies the read noise and the dark noise, thus limiting the imaging dynamic range. Through an in-depth analysis of the information transfer model of digital TDI, this paper attempts to explore effective ways to overcome this issue. Based on the evaluation and analysis of multi-stage images, the entropy-maximized adaptive histogram equalization (EMAHE algorithm is proposed to improve the ability of images to express the details of dark or low-contrast targets. Furthermore, in this paper, an image fusion method is utilized based on gradient pyramid decomposition and entropy weighting of different TDI stage images, which can improve the detection ability of the digital TDI CMOS for complex scenes with high contrast, and obtain images that are suitable for recognition by the human eye. The experimental results show that the proposed methods can effectively improve the high-dynamic-range imaging (HDRI capability of the digital TDI CMOS. The obtained images have greater entropy and average gradients.

  17. Ischemic Tolerance of the Brain and Spinal Cord: A Review.

    Science.gov (United States)

    Yunoki, Masatoshi; Kanda, Takahiro; Suzuki, Kenta; Uneda, Atsuhito; Hirashita, Koji; Yoshino, Kimihiro

    2017-11-15

    Ischemic tolerance is an endogenous neuroprotective phenomenon induced by sublethal ischemia. Ischemic preconditioning (IPC), the first discovered form of ischemic tolerance, is widely seen in many species and in various organs including the brain and the spinal cord. Ischemic tolerance of the spinal cord is less familiar among neurosurgeons, although it has been reported from the viewpoint of preventing ischemic spinal cord injury during aortic surgery. It is important for neurosurgeons to have opportunities to see patients with spinal cord ischemia, and to understand ischemic tolerance of the spinal cord as well as the brain. IPC has a strong neuroprotective effect in animal models of ischemia; however, clinical application of IPC for ischemic brain and spinal diseases is difficult because they cannot be predicted. In addition, one drawback of preconditioning stimuli is that they are also capable of producing injury with only minor changes to their intensity or duration. Numerous methods to induce ischemic tolerance have been discovered that vary in their timing and the site at which short-term ischemia occurs. These methods include ischemic postconditioning (IPoC), remote ischemic preconditioning (RIPC), remote ischemic perconditioning (RIPerC) and remote ischemic postconditioning (RIPoC), which has had a great impact on clinical approaches to treatment of ischemic brain and spinal cord injury. Especially RIPerC and RIPoC to induce spinal cord tolerance are considered clinically useful, however the evidence supporting these methods is currently insufficient; further experimental or clinical research in this area is thus necessary.

  18. Proximal spinal muscular atrophy: current orthopedic perspective

    Directory of Open Access Journals (Sweden)

    Haaker G

    2013-11-01

    Full Text Available Gerrit Haaker, Albert Fujak Department of Orthopaedic Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany Abstract: Spinal muscular atrophy (SMA is a hereditary neuromuscular disease of lower motor neurons that is caused by a defective "survival motor neuron" (SMN protein that is mainly associated with proximal progressive muscle weakness and atrophy. Although SMA involves a wide range of disease severity and a high mortality and morbidity rate, recent advances in multidisciplinary supportive care have enhanced quality of life and life expectancy. Active research for possible treatment options has become possible since the disease-causing gene defect was identified in 1995. Nevertheless, a causal therapy is not available at present, and therapeutic management of SMA remains challenging; the prolonged survival is increasing, especially orthopedic, respiratory and nutritive problems. This review focuses on orthopedic management of the disease, with discussion of key aspects that include scoliosis, muscular contractures, hip joint disorders, fractures, technical devices, and a comparative approach of conservative and surgical treatment. Also emphasized are associated complications including respiratory involvement, perioperative care and anesthesia, nutrition problems, and rehabilitation. The SMA disease course can be greatly improved with adequate therapy with established orthopedic procedures in a multidisciplinary therapeutic approach. Keywords: spinal muscular atrophy, scoliosis, contractures, fractures, lung function, treatment, rehabilitation, surgery, ventilation, nutrition, perioperative management

  19. Radiation effects in brain and spinal cord

    International Nuclear Information System (INIS)

    Franke, H.D.; Lierse, W.

    1978-01-01

    Radiation sensitivity of both the brain and spinal cord in prenatal and postnatal stages, in infancy and adult age is represented also in consideration of a combined treatment with methotrexate. In adults, application of important doses of high-energy radiation increases the risk of injurious effects to the central nervous system. If the spinal cord is involved, more than 60% of the radiolesions have a progredient course ending with death. The pathogenesis and disposing factors are referred to, and the incidence of radiation necrosis with regard to age and sex, the degrees of injury and their frequence within different ranges of dosage are analyzed on the basis of data from universal literature. An examination of 'tolerance doses' for the spinal cord is made by means of Strandquist-diagrams and of the Ellis-formula. The slopes of regression lines are reported for various 'degrees of response' in skin, brain and spinal cord following radiation therapy. In the Strandquist-diagram, slopes of regression lines are dependent on the 'degree of response', flattening if skin and spinal cord are affected by radiation in the same degree, necroses having the same slope for both the organs. (orig./MG) [de

  20. Prenatal exposure to fenugreek impairs sensorimotor development and the operation of spinal cord networks in mice.

    Directory of Open Access Journals (Sweden)

    Loubna Khalki

    Full Text Available Fenugreek is a medicinal plant whose seeds are widely used in traditional medicine, mainly for its laxative, galactagogue and antidiabetic effects. However, consumption of fenugreek seeds during pregnancy has been associated with a range of congenital malformations, including hydrocephalus, anencephaly and spina bifida in humans. The present study was conducted to evaluate the effects of prenatal treatment of fenugreek seeds on the development of sensorimotor functions from birth to young adults. Pregnant mice were treated by gavage with 1 g/kg/day of lyophilized fenugreek seeds aqueous extract (FSAE or distilled water during the gestational period. Behavioral tests revealed in prenatally treated mice a significant delay in righting, cliff avoidance, negative geotaxis responses and the swimming development. In addition, extracellular recording of motor output in spinal cord isolated from neonatal mice showed that the frequency of spontaneous activity and fictive locomotion was reduced in FSAE-exposed mice. On the other hand, the cross-correlation coefficient in control mice was significantly more negative than in treated animals indicating that alternating patterns are deteriorated in FSAE-treated animals. At advanced age, prenatally treated mice displayed altered locomotor coordination in the rotarod test and also changes in static and dynamic parameters assessed by the CatWalk automated gait analysis system. We conclude that FSAE impairs sensorimotor and coordination functions not only in neonates but also in adult mice. Moreover, spinal neuronal networks are less excitable in prenatally FSAE-exposed mice suggesting that modifications within the central nervous system are responsible, at least in part, for the motor impairments.

  1. Tolerance of the human spinal cord to single dose radiosurgery

    International Nuclear Information System (INIS)

    Ryu, S.; Zhu, G.; Yin, F.-F.; Ajlouni, M.; Kim, J.H.

    2003-01-01

    Tolerance of the spinal cord to the single dose of radiation is not well defined. Although there are cases of human spinal cord tolerance from re-irradiation to the same cord level, the information about the tolerance of human spinal cord to single large dose of radiosurgery is not available. We carried out spinal radiosurgery to treat spinal metastasis and studied the single dose tolerance of the human spinal cord in an ongoing dose escalation paradigm. A total of 39 patients with 48 lesions of spinal metastasis were treated with single dose radiosurgery at Henry Ford Hospital. The radiosurgery dose was escalated from 8 Gy to 16 Gy at 2 Gy increment. The radiation dose was prescribed to periphery of the spinal tumor. The radiation dose to the spinal cord was estimated by computerized dosimetry. The median follow-up time was 10 months (range 6-18 months) from the radiosurgery. The endpoint of the study was to demonstrate the efficacy of the spinal radiosurgery and to determine the tolerance of human spinal cord to single dose radiosurgery. The dose to the spinal cord was generally less than 50 % of the prescribed radiation dose. The volume of the spinal cord that received higher than this dose was less than 20 % of the anterior portion of the spinal cord. Maximum single dose of 8 Gy was delivered to the anterior 20 % of the spinal cord in this dose escalation study. The dose volume histogram will be presented. There was no acute or subacute radiation toxicity detected clinically and radiologically during the maximum follow-up of 20 months. Further dose escalation is in progress. The single tolerance dose of the human spinal cord appears to be at least 8 Gy when it was given to the 20 % of the cord volume, although the duration of follow up is not long enough to detect severe late cord toxicity. This study offers a valuable radiobiological basis of the normal spinal cord tolerance, and opens spinal radiosurgery as a safe treatment for spinal metastasis

  2. Computed tomography of the spinal canal for the cervical spine and spinal cord injury

    International Nuclear Information System (INIS)

    Kimura, Isao; Niimiya, Hikosuke; Nasu, Kichiro; Shioya, Akihide; Ohhama, Mitsuru

    1983-01-01

    The cervical spinal canal and cervical spinal cord were measured in normal cases and 34 cases of spinal or spinal cord injury. The anteroposterior diameter and area of the normal cervical spinal canal showed a high correlation. The area ratio of the normal cervical spinal canal to the cervical spinal cord showed that the proportion of the cervical spinal cord in the spinal canal was 1/3 - 1/5, Csub(4,5) showing a particularly large proportion. In acute and subacute spinal or spinal cord injury, CT visualized in more details of the spinal canal in cases that x-ray showed definite bone injuries. Computer assisted myelography visualized more clearly the condition of the spinal cord in cases without definite findings bone injuries on x-ray. Demonstrating the morphology of spinal injury in more details, CT is useful for selection of therapy for injured spines. (Chiba, N.)

  3. A low-power high dynamic range front-end ASIC for imaging calorimeters

    CERN Document Server

    Bagliesi, M G; Marrocchesi, P S; Meucci, M; Millucci, V; Morsani, F; Paoletti, R; Pilo, F; Scribano, A; Turini, N; Valle, G D

    2002-01-01

    High granularity calorimeters with shower imaging capabilities require dedicated front-end electronics. The ICON 4CH and VA4 PMT chip-set is suitable for very high dynamic range systems with strict noise requirements. The ICON 4CH is a 4 channel input, 12 channel output ASIC designed for use in a multi-anode photomultiplier system with very large dynamic range and low-noise requirements. Each of the four input signals to the ASIC is split equally into three branches by a current conveyor. Each of the three branches is scaled differently: 1:1, 1:8 and 1:80. The signal is read out by a 12 channel low noise/low power high dynamic range charge sensitive preamplifier-shaper circuit (VA4-PMT chip), with simultaneous sample- and-hold, multiplexed analog read-out, calibration facilities. Tests performed in our lab with a PMT are reported in terms of linearity, dynamic range and cross-talk of the system. (5 refs).

  4. Extending the Dynamic Range of a Time Projection Chamber

    Science.gov (United States)

    Estee, Justin; S πRIT Collaboration

    2017-09-01

    The use of Time Projection Chambers (TPCs) in intermediate heavy ion reactions faces some challenges in addressing the energy losses that range from the small energy loss of relativistic pions to the large energy loss of slow moving heavy ions. A typical trade-off can be to set the smallest desired signals to be well within the lower limits of the dynamic range of the electronics while allowing for some larger signals to saturate the electronics. With wire plane anodes, signals from readout pads further away from the track remain unsaturated and allow signals from tracks with saturated pads to be accurately recovered. We illustrate this technique using data from the SAMURAI Pion-Reconstruction and Ion-Tracker (S πRIT) TPC , which recently measured pions and light charged particles in collisions of Sn+Sn isotopes. Our method exploits knowledge of how the induced charge distribution depends on the distance from the track to smoothly extend dynamic range even when some of the pads in the track are saturated. To accommodate the analysis of slow moving heavy ions, we have extended the Bichsel energy loss distributions to handle slower moving ions as well. In this talk, I will discuss a combined approach which successfully extends the dynamic range of the TPC electronics. This work is supported by the U.S. DOE under Grant Nos. DE-SC0014530, DE-NA0002923, US NSF Grant No. PHY-1565546 and the Japan MEXT KAKENHI Grant No. 24105004.

  5. Surface impedance of superconductors in wide frequency ranges for wake field calculations

    International Nuclear Information System (INIS)

    Davidovskii, V.G.

    2006-01-01

    The problem of the surface impedance of superconductors in wide frequency ranges for calculations of wake fields, generated by bunches of charged particles moving axially inside a metallic vacuum chambers, is solved. The case of specular electron reflection at the superconductor surface is considered. The expression for the surface impedance of superconductors suitable for numerical computation is derived [ru

  6. Forcing mechanisms and hydrodynamics in Loch Linnhe, a dynamically wide Scottish estuary

    Science.gov (United States)

    Rabe, Berit; Hindson, Jennifer

    2017-09-01

    Hydrodynamic conditions in Loch Linnhe, a dynamifcally wide estuary on the west coast of Scotland, are primarily influenced by wind forcing, freshwater input, and tides. Winds in the region are orographically steered along the axis of the estuary due to surrounding mountains. A large rainfall catchment area results in a large freshwater inflow into Loch Linnhe which in turn produces low salinity waters at the head of the estuary. This, combined with a connection to the open sea with coastal salinities, leads to salinity gradients in the horizontal and vertical. Even though a range of observational programmes have focussed on Loch Linnhe, the literature still lacks an evaluation of its physical dynamics. Here we present a first description of the hydrodynamics in Loch Linnhe based on observations. Wind stress predominantly influences the surface layer, especially at low frequencies and with a stronger influence than tides during neap tides. The buoyancy-driven flow due to the large river runoff influences the circulation independent of wind stress. Seasonal (spring, autumn) and interannual (2011, 2012) variability of water masses occur especially in the surface layer. Tides are dominated by the semi-diurnal constituent M2 with tidal ellipses aligned in the along-estuary direction and a stronger influence during spring tides compared to wind. An evaluation of dimensionless numbers reveal laterally and vertically sheared exchange flows. Compared to other Scottish estuaries Loch Linnhe is wide enough to be influenced by the Earth's rotation and demonstrates an enhanced freshwater outflow along its north-western coast as the freshwater is diverted to the right in the direction of the flow. These observed patterns are important for the sustainable environmental management of this socio-economically valuable region, e.g. through their relevance to aquaculture pathogen transmission patterns. A thorough understanding of the dynamics of the system is essential for a

  7. Spinal Cord Injury 101

    Medline Plus

    Full Text Available menu Understanding Spinal Cord Injury What is a Spinal Cord Injury Levels of Injury and What They Mean Animated Spinal Cord Injury Chart Spinal Cord Injury Facts and Figures Care and Treatment After SCI Spinal ...

  8. Wide range neutron monitoring device

    International Nuclear Information System (INIS)

    Okido, Fumiyasu; Arita, Setsuo; Ishii, Kazuhiko; Matsumiya, Shoichi; Furusato, Ken-ichiro; Nishida, Akira.

    1994-01-01

    The present invention has a function of reliably switching measuring values between a pulse method and a Cambel method even if noise level and saturated level are fluctuated. That is, a proportional range judging means always monitors neutron flux measuring values in a start-up region and neutron flux measuring values in an intermediate power region, so that the proportional range is detected depending on whether the difference or a variation coefficient of both of the measured values is constant or not. A switching value determining means determines a switching value by the result of judgement of the proportional range judging means. A selection/output means selects and outputs measuring signals at a neutron flux level in the start-up region or the intermediate power region by the output of the switching value determining means. With such procedures, since the measuring value is switched after confirming that arrival at the proportional range where the difference or a variation coefficient of the measured value between the pulse processing method and the measured value by the Cambel method is constant, an accurate neutron flux level containing neither noise level nor saturated level can be outputted. (I.S.)

  9. A Bidirectional Resonant DC-DC Converter Suitable for Wide Voltage Gain Range

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Al-Durra, Ahmed

    2018-01-01

    This paper proposes a new bidirectional resonant dc-dc converter suitable for wide voltage gain range applications (e.g., energy storage systems). The proposed converter overcomes the narrow voltage gain range of conventional resonant dc-dc converters, and meanwhile achieves high efficiency...... losses. The operation principles and characteristics of the proposed converter are firstly analyzed in this paper. Then the analytical solutions for the voltage gain, soft-switching, and rms currents are derived, which facilitates the parameters design and optimization. Finally, the proposed topology...... and analysis are verified with experimental results obtained from a 1-kW converter prototype....

  10. Understanding synthesis imaging dynamic range

    Science.gov (United States)

    Braun, R.

    2013-03-01

    We develop a general framework for quantifying the many different contributions to the noise budget of an image made with an array of dishes or aperture array stations. Each noise contribution to the visibility data is associated with a relevant correlation timescale and frequency bandwidth so that the net impact on a complete observation can be assessed when a particular effect is not captured in the instrumental calibration. All quantities are parameterised as function of observing frequency and the visibility baseline length. We apply the resulting noise budget analysis to a wide range of existing and planned telescope systems that will operate between about 100 MHz and 5 GHz to ascertain the magnitude of the calibration challenges that they must overcome to achieve thermal noise limited performance. We conclude that calibration challenges are increased in several respects by small dimensions of the dishes or aperture array stations. It will be more challenging to achieve thermal noise limited performance using 15 m class dishes rather than the 25 m dishes of current arrays. Some of the performance risks are mitigated by the deployment of phased array feeds and more with the choice of an (alt,az,pol) mount, although a larger dish diameter offers the best prospects for risk mitigation. Many improvements to imaging performance can be anticipated at the expense of greater complexity in calibration algorithms. However, a fundamental limitation is ultimately imposed by an insufficient number of data constraints relative to calibration variables. The upcoming aperture array systems will be operating in a regime that has never previously been addressed, where a wide range of effects are expected to exceed the thermal noise by two to three orders of magnitude. Achieving routine thermal noise limited imaging performance with these systems presents an extreme challenge. The magnitude of that challenge is inversely related to the aperture array station diameter.

  11. Modal density of rectangular structures in a wide frequency range

    Science.gov (United States)

    Parrinello, A.; Ghiringhelli, G. L.

    2018-04-01

    A novel approach to investigate the modal density of a rectangular structure in a wide frequency range is presented. First, the modal density is derived, in the whole frequency range of interest, on the basis of sound transmission through the infinite counterpart of the structure; then, it is corrected by means of the low-frequency modal behavior of the structure, taking into account actual size and boundary conditions. A statistical analysis reveals the connection between the modal density of the structure and the transmission of sound through its thickness. A transfer matrix approach is used to compute the required acoustic parameters, making it possible to deal with structures having arbitrary stratifications of different layers. A finite element method is applied on coarse grids to derive the first few eigenfrequencies required to correct the modal density. Both the transfer matrix approach and the coarse grids involved in the finite element analysis grant high efficiency. Comparison with alternative formulations demonstrates the effectiveness of the proposed methodology.

  12. Decreased spinal synaptic inputs to phrenic motor neurons elicit localized inactivity-induced phrenic motor facilitation.

    Science.gov (United States)

    Streeter, K A; Baker-Herman, T L

    2014-06-01

    Phrenic motor neurons receive rhythmic synaptic inputs throughout life. Since even brief disruption in phrenic neural activity is detrimental to life, on-going neural activity may play a key role in shaping phrenic motor output. To test the hypothesis that spinal mechanisms sense and respond to reduced phrenic activity, anesthetized, ventilated rats received micro-injections of procaine in the C2 ventrolateral funiculus (VLF) to transiently (~30min) block axon conduction in bulbospinal axons from medullary respiratory neurons that innervate one phrenic motor pool; during procaine injections, contralateral phrenic neural activity was maintained. Once axon conduction resumed, a prolonged increase in phrenic burst amplitude was observed in the ipsilateral phrenic nerve, demonstrating inactivity-induced phrenic motor facilitation (iPMF). Inhibition of tumor necrosis factor alpha (TNFα) and atypical PKC (aPKC) activity in spinal segments containing the phrenic motor nucleus impaired ipsilateral iPMF, suggesting a key role for spinal TNFα and aPKC in iPMF following unilateral axon conduction block. A small phrenic burst amplitude facilitation was also observed contralateral to axon conduction block, indicating crossed spinal phrenic motor facilitation (csPMF). csPMF was independent of spinal TNFα and aPKC. Ipsilateral iPMF and csPMF following unilateral withdrawal of phrenic synaptic inputs were associated with proportional increases in phrenic responses to chemoreceptor stimulation (hypercapnia), suggesting iPMF and csPMF increase phrenic dynamic range. These data suggest that local, spinal mechanisms sense and respond to reduced synaptic inputs to phrenic motor neurons. We hypothesize that iPMF and csPMF may represent compensatory mechanisms that assure adequate motor output is maintained in a physiological system in which prolonged inactivity ends life. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Trophodynamics of inorganic pollutants in a wide-range feeder: The relevance of dietary inputs and biomagnification in the Yellow-legged gull (Larus michahellis)

    International Nuclear Information System (INIS)

    Ramos, Raül; Ramírez, Francisco; Jover, Lluís

    2013-01-01

    The suitability of sentinel species to monitor environmental pollution is often hampered by an insufficient knowledge on pollutant trophodynamics. We simultaneously evaluated the influence of individuals' trophic position (as revealed by δ 15 N values) and dietary exploitation of particular systems (using δ 13 C and δ 34 S as proxies) on inorganic pollutant concentrations measured on fledglings' feathers of a wide-range feeder, the Yellow-legged Gull (Larus michahellis), sampled at four locations throughout the Western Mediterranean. Concentrations of total Hg and Se in fledgling feathers (2.43 ± 1.30 and 1.16 ± 0.43 μg/g, respectively) were under the threshold points for deleterious effects on seabirds. On the contrary, alarming Pb concentrations were found in one colony (mean: 1.57 ± 2.46 μg/g, range: 0.16–12.13). With the exception of Pb, pollutant concentrations were positively influenced by consumption of marine resources (as suggested by the positive relationship with δ 34 S values), whereas trophic position played a minor role in determining pollutant body burdens. - Graphical abstract: Individual feeding behaviours in wide-range feeders may represent unavoidable knowledge for an appropriate understanding of contaminant acquisition, adding complexity to the study of the dynamic of contaminants throughout food chains. In this case study, pollutant body burden of Yellow-legged gull (Larus michahellis) chicks was highly influenced by dietary exposure, whereas the influence of trophic position was relatively low. Display Omitted Highlights: ► Diet origin (δ 34 S) and trophic position (δ 15 N) were tested relative to Hg, Se, and Pb levels. ► Hg and Se concentrations in gull feathers were highly influenced by δ 34 S signatures. ► Exploited habitat influenced pollutant levels to a greater extent than trophic position. ► Biomagnification processes contribute less to contamination exposure in wide-range feeders. - Pollutant body burden of a wide-range

  14. Dynamic range studies of the RCA streak tube in the LLL streak camera

    International Nuclear Information System (INIS)

    Thomas, S.W.; Phillips, G.E.

    1979-01-01

    As indicated by tests on several cameras, the dynamic range of the Lawrence Livermore Laboratory streak-camera system appears to be about two orders of magnitude greater than those reported for other systems for 10- to 200-ps pulses. The lack of a fine mesh grid in the RCA streak tube used in these cameras probably contributes to a lower system dynamic noise and therefore raises the dynamic range. A developmental tube with a mesh grid was tested and supports this conjecture. Order-of-magnitude variations in input slit width do not affect the spot size on the phosphor or the dynamic range of the RCA tube. (author)

  15. Dynamic range compression in a liquid argon calorimeter

    International Nuclear Information System (INIS)

    Cleland, W.E.; Lissauer, D.; Radeka, V.; Rescia, S.; Takai, H.; Wingerter-Seez, I.

    1996-01-01

    The anticipated range of particle energies at the LHC, coupled with the need for precision, low noise calorimetry makes severe demands on the dynamic range of the calorimeter readout. A common approach to this problem is to use shapers with two or more gain scales. In this paper, the authors describe their experience with a new approach in which a preamplifier with dynamic gain compression is used. An unavoidable consequence of dynamic gain adjustment is that the peaking time of the shaper output signal becomes amplitude dependent. The authors have carried out a test of such a readout system in the RD3 calorimeter, a liquid argon device with accordion geometry. The calibration system is used to determine both the gain of the individual channels as well as to map the shape of the waveform as a function of signal amplitude. A new procedure for waveform analysis, in which the fitted parameters describe the impulse response of the system, permits a straightforward translation of the calibration waveform to the waveform generated by a particle crossing the ionization gap. They find that the linearity and resolution of the calorimeter is equivalent to that obtained with linear preamplifiers, up to an energy of 200 GeV

  16. A digitized wide range channel for new instrumentation and control system of PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Zareen Khan Abdul Jalil Khan; Izhar Abu Hussin; Mohd Idris Taib; Nurfarhana Ayuni Joha; Roslan Md Dan

    2010-01-01

    Wide Range Channel is one of very important part of Reactor Instrumentation and Control system. Current system is using all analog system. The main functions of the new system are to provide Wide-log power and Multi-range linear power. The other functions are to provide Percent power and Power rate of change. The linear power level range is up to 125 % and the log power system to cover from below source level to 150 %. The main function of digital signal processor is for pulse shaping, pulse counting and root mean square signal processing. The system employs automatic on-line self diagnostics and calibration verification. (author)

  17. Wide Temperature Range DC-DC Boost Converters for Command/Control/Drive Electronics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We shall develop wide temperature range DC-DC boost converters that can be fabricated using commercial CMOS foundries. The boost converters will increase the low...

  18. Dynamic range extension of BPM at the NSLS

    International Nuclear Information System (INIS)

    Bordoley, M.

    1993-01-01

    In order to overcome range limitations, the existing Beam Position Monitor (BPM) receiver was modified, extending the dynamic range from 35 dB to 60 dB. The modifications include the insertion of an RF PIN attenuator, RF amplifier, and control circuitry in line with the RF link to add an extra 25dB to the existing AGC loop. This stand alone 25dB RF gain control stage is integrated into the present system without any change to the existing receiver

  19. Comparisons of MR findings of the spinal metastasis and the spinal tuberculosis

    International Nuclear Information System (INIS)

    Hong, Myung Sun; Lee, Kil Woo; Kang, Ik Won; Yun, Ku Sub; Choi, Chul Sun; Bae, Sang Hoon

    1994-01-01

    MR findings of the spinal metastasis and the tuberculosis are well known, but sometimes it might be difficult to differentiate these lesions. Therefore we reviewed and analyzed the MR findings which would be useful for the differentiation. T1- and T2- weighted spin echo images and gadolinium-enhanced T1- weighted images were obtained with 1.5 T and 1.0 T superconductive MR imager. We reviewed MR findings in 16 cases of spinal metastases and 24 cases of spinal tuberculosis in terms of signal intensity, contrast enhancement pattern, disc space involvement, spinal canal compressing feature and paraspinal soft tissue mass. The signal intensities of both lesions were hypointense on T1WI and hyperintense on T2WI except those of the metastatic lesions from the prostatic carcinoma. Heterogeneous enhancement was noted in 63% of metastasis, whereas peripheral rim enhancement was noted 83% of spinal tuberculosis(p < .001). Spinal canal compression by collapsed vertebra was only noted in spinal metastasis, and that by paraspinal soft tissue was noted in both spinal metastasis and tuberculosis(p<.001). Disc space invasion was noted in 19% of spinal metastasis and 88% of spinal tuberculosis. Spinal tuberculosis was common at lower thoracic spine(T10) and typically involved two or more adjacent vertebral bodies(96%). The important differential point between spinal metastasis and tuberculosis was the enhancement pattern, involvement of two or more contiguous vertebral bodies and the feature of spinal canal compressing. The secondary importance was the disc space involvement pattern

  20. Evo-engineering and the cellular and molecular origins of the vertebrate spinal cord.

    Science.gov (United States)

    Steventon, Ben; Martinez Arias, Alfonso

    2017-12-01

    The formation of the spinal cord during early embryonic development in vertebrate embryos is a continuous process that begins at gastrulation and continues through to the completion of somitogenesis. Despite the conserved usage of patterning mechanisms and gene regulatory networks that act to generate specific spinal cord progenitors, there now exists two seemingly disparate models to account for their action. In the first, a posteriorly localized signalling source transforms previously anterior-specified neural plate into the spinal cord. In the second, a population of bipotent stem cells undergo continuous self-renewal and differentiation to progressively lay down the spinal cord and axial mesoderm by posterior growth. Whether this represents fundamental differences between the experimental model organisms utilised in the generation of these models remains to be addressed. Here we review lineage studies across four key vertebrate models: mouse, chicken, Xenopus and zebrafish and relate them to the underlying gene regulatory networks that are known to be required for spinal cord formation. We propose that by applying a dynamical systems approach to understanding how distinct neural and mesodermal fates arise from a bipotent progenitor pool, it is possible to begin to understand how differences in the dynamical cell behaviours such as proliferation rates and cell movements can map onto conserved regulatory networks to generate diversity in the timing of tissue generation and patterning during development. Copyright © 2017. Published by Elsevier Inc.

  1. Dynamic Contrast Enhanced Magnetic Resonance Imaging of Diffuse Spinal Bone Marrow Infiltration in Patients with Hematological Malignancies

    International Nuclear Information System (INIS)

    Zha, Yunfei; Li, Maojin; Yang, Jianyong

    2010-01-01

    To investigate the significance of the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) parameters of diffuse spinal bone marrow infiltration in patients with hematological malignancies. Dynamic gadolinium-enhanced MR imaging of the lumbar spine was performed in 26 patients with histologically proven diffuse bone marrow infiltration, including multiple myeloma (n = 6), acute lymphoblastic leukemia (n = 6), acute myeloid leukemia (n = 5), chronic myeloid leukemia (n = 7), and non-Hodgkin lymphoma (n = 2). Twenty subjects whose spinal MRI was normal, made up the control group. Peak enhancement percentage (E max ), enhancement slope (ES), and time to peak (TTP) were determined from a time intensity curve (TIC) of lumbar vertebral bone marrow. A comparison between baseline and follow-up MR images and its histological correlation were evaluated in 10 patients. The infiltration grade of hematopoietic marrow with plasma cells was evaluated by a histological assessment of bone marrow. Differences in E max , ES, and TTP values between the control group and the patients with diffuse bone marrow infiltration were significant (t = -11.51, -9.81 and 3.91, respectively, p max , ES, and TTP values were significantly different between bone marrow infiltration groups Grade 1 and Grade 2 (Z = -2.72, -2.24 and -2.89 respectively, p max , ES and TTP values were not significantly different between bone marrow infiltration groups Grade 2 and Grade 3 (Z = -1.57, -1.82 and -1.58 respectively, p > 0.05). A positive correlation was found between E max , ES values and the histological grade of bone marrow infiltration (r = 0.86 and 0.84 respectively, p max and ES values was observed with increased TTP values after treatment in all of the 10 patients who responded to treatment (t = -7.92, -4.55, and 5.12, respectively, p max , ES, and TTP can reflect the malignancies' histological grade

  2. Gastrocnemius muscle contracture after spinal cord injury: a longitudinal study.

    Science.gov (United States)

    Diong, Joanna; Harvey, Lisa A; Kwah, Li Khim; Clarke, Jillian L; Bilston, Lynne E; Gandevia, Simon C; Herbert, Robert D

    2013-07-01

    The aim of this study was to examine changes in passive length and stiffness of the gastrocnemius muscle-tendon unit in people after spinal cord injury. In a prospective longitudinal study, eight wheelchair-dependent participants with severe paralysis were assessed 3 and 12 mos after spinal cord injury. Passive torque-angle data were obtained as the ankle was slowly rotated through range at six knee angles. Differences in passive ankle torque-angle data recorded at different knee angles were used to derive passive length-tension curves of the gastrocnemius muscle-tendon unit. Ultrasound imaging was used to determine fascicle and tendon contributions to the muscle-tendon unit length-tension curves. The participants had ankle contractures (mean [SD] maximum passive ankle dorsiflexion angle, 88 [9] degrees) 3 mos after spinal cord injury. Ankle range did not worsen significantly during the subsequent 9 mos (mean change, -5 degrees; 95% confidence interval, -16 to 6 degrees). There were no changes in the mean slack length or the stiffness of the gastrocnemius muscle-tendon unit or in the slack lengths of the fascicles or the tendon between 3 and 12 mos after spinal cord injury. There were no consistent patterns of the change in slack length or stiffness with the changes in ankle range in the data from the individual participants. This study, the first longitudinal study of muscle length and stiffness after spinal cord injury, showed that the length and the stiffness of the gastrocnemius did not change substantially between 3 and 12 mos after injury.

  3. Congenital spine anomalies: the closed spinal dysraphisms

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Erin Simon [University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Perelman School of Medicine, Philadelphia, PA (United States); Rossi, Andrea [G. Gaslini Children' s Hospital, Department of Radiology, Genoa (Italy)

    2015-09-15

    The term congenital spinal anomalies encompasses a wide variety of dysmorphology that occurs during early development. Familiarity with current terminology and a practical, clinico-radiologic classification system allows the radiologist to have a more complete understanding of malformations of the spine and improves accuracy of diagnosis when these entities are encountered in practice. (orig.)

  4. A wide-frequency range AC magnetometer to measure the specific absorption rate in nanoparticles for magnetic hyperthermia

    International Nuclear Information System (INIS)

    Garaio, E.; Collantes, J.M.; Garcia, J.A.; Plazaola, F.; Mornet, S.; Couillaud, F.; Sandre, O.

    2014-01-01

    Measurement of specific absorption rate (SAR) of magnetic nanoparticles is crucial to assert their potential for magnetic hyperthermia. To perform this task, calorimetric methods are widely used. However, those methods are not very accurate and are difficult to standardize. In this paper, we present AC magnetometry results performed with a lab-made magnetometer that is able to obtain dynamic hysteresis-loops in the AC magnetic field frequency range from 50 kHz to 1 MHz and intensities up to 24 kA m −1 . In this work, SAR values of maghemite nanoparticles dispersed in water are measured by AC magnetometry. The so-obtained values are compared with the SAR measured by calorimetric methods. Both measurements, by calorimetry and magnetometry, are in good agreement. Therefore, the presented AC magnetometer is a suitable way to obtain SAR values of magnetic nanoparticles. - Highlights: • We propose AC magnetometry as a method to measure the specific absorption rate (SAR) of magnetic nanoparticles suitable for magnetic hyperthermia therapy. • We have built a lab-made AC magnetometer, which is able to measure magnetic dynamic hysteresis-loops of nanoparticle dispersions. • The device works with AC magnetic field intensities up to 24 kA m −1 in a frequency range from 75 kHz to 1 MHz. • The SAR values of maghemite nanoparticles around 12 nm in magnetic diameter dispersed in water are measured by the lab-made magnetometer and different calorimetric methods. • Although all methods are in good agreement, several factors (probe location, thermal inertia, losses, etc.) make calorimetric method less accurate than AC magnetometry

  5. GaN-based High Power High Frequency Wide Range LLC Resonant Converter, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — SET Group will design, build and demonstrate a Gallium Nitride (GaN) based High Power High Frequency Wide Range LLC Resonant Converter capable of handling high power...

  6. Are existing outcome instruments suitable for assessment of spinal trauma patients?

    Science.gov (United States)

    Stadhouder, Agnita; Buckens, Constantinus F M; Holtslag, Herman R; Oner, F Cumhur

    2010-11-01

    Valid outcome assessment tools specific for spinal trauma patients are necessary to establish the efficacy of different treatment options. So far, no validated specific outcome measures are available for this patient population. The purpose of this study was to assess the current state of outcome measurement in spinal trauma patients and to address the question of whether this group is adequately served by current disease-specific and generic health-related quality-of-life instruments. A number of widely used outcome measures deemed most appropriate were reviewed, and their applicability to spinal trauma outcome discussed. An overview of recent movements in the theoretical foundations of outcome assessment, as it pertains to spinal trauma patients has been attempted, along with a discussion of domains important for spinal trauma. Commonly used outcome measures that are recommended for use in trauma patients were reviewed from the perspective of spinal trauma. The authors further sought to select a number of spine trauma-relevant domains from the WHO's comprehensive International Classification of Functioning, Disability and Health (ICF) as a benchmark for assessing the content coverage of the commonly used outcome measurements reviewed. The study showed that there are no psychometrically validated outcome measurements for the spinal trauma population and there are no commonly used outcome measures that provide adequate content coverage for spinal trauma domains. Spinal trauma patients are currently followed either as a subset of the polytrauma population in the acute and early postacute setting or as a subset of neurological injury in the long-term revalidation medicine setting.

  7. Constitutive modeling of polycarbonate over a wide range of strain rates and temperatures

    Science.gov (United States)

    Wang, Haitao; Zhou, Huamin; Huang, Zhigao; Zhang, Yun; Zhao, Xiaoxuan

    2017-02-01

    The mechanical behavior of polycarbonate was experimentally investigated over a wide range of strain rates (10^{-4} to 5× 103 s^{-1}) and temperatures (293 to 353 K). Compression tests under these conditions were performed using a SHIMADZU universal testing machine and a split Hopkinson pressure bar. Falling weight impact testing was carried out on an Instron Dynatup 9200 drop tower system. The rate- and temperature-dependent deformation behavior of polycarbonate was discussed in detail. Dynamic mechanical analysis (DMA) tests were utilized to observe the glass (α ) transition and the secondary (β ) transition of polycarbonate. The DMA results indicate that the α and β transitions have a dramatic influence on the mechanical behavior of polycarbonate. The decompose/shift/reconstruct (DSR) method was utilized to decompose the storage modulus into the α and β components and extrapolate the entire modulus, the α-component modulus and the β-component modulus. Based on three previous models, namely, Mulliken-Boyce, G'Sell-Jonas and DSGZ, an adiabatic model is proposed to predict the mechanical behavior of polycarbonate. The model considers the contributions of both the α and β transitions to the mechanical behavior, and it has been implemented in ABAQUS/Explicit through a user material subroutine VUMAT. The model predictions are proven to essentially coincide with the experimental results during compression testing and falling weight impact testing.

  8. A Fixed-Frequency Bidirectional Resonant DC-DC Converter Suitable for Wide Voltage Gain Range

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Blaabjerg, Frede

    2017-01-01

    This paper proposes a new bidirectional resonant dc-dc converter suitable for wide voltage gain range applications (e.g., energy storage systems). The proposed converter overcomes the narrow voltage gain range of conventional resonant DC-DC converters, and meanwhile achieves high efficiency...... and characteristics of the proposed converter are analyzed. Finally, a 1-kW converter prototype is built and the experimental results verify the theoretical analyses....

  9. Evaluating the impact of a wide range of vegetation densities on river channel pattern

    Science.gov (United States)

    Pattison, Ian; Roucou, Ron

    2016-04-01

    Braided rivers are very dynamic systems which have complex controls over their planform and flow dynamics. Vegetation is one variable which influences channel geometry and pattern, through its effect on local flow hydraulics and the process continuum of sediment erosion-transport-deposition. Furthermore, where in the braided floodplain stable vegetation develops depends on the temporal sequencing of the river discharge i.e. floods. Understanding the effect of vegetation in these highly dynamic systems has multiple consequences for human activity and floodplain management. This paper focusses on the specific role of vegetation density in controlling braided river form and processes. Previous research in this field has been contradictory; with Gran and Paola (2001) finding that increasing vegetation density decreased the number of active channels. In contrast, Coulthard (2005] observed that as vegetation become denser there was an increase in the number of channels. This was hypothesized to be caused by flow separation around vegetation and the development of bars immediately downstream of the plant. This paper reports the results from a set of experiments in a 4m by 1m flume, where discharge, slope and sediment size were kept constant. Artificial grass was used to represent vegetation with a density ranging from 50 plants/m2 to 400 plants/m2. Digital photographs, using a GoPro camera with a fish eye lens, were taken from ~1m above the flume at an interval of 30 seconds during the 3 hour experiment. The experiments showed that as the vegetation density increased from 50 to 150 plants/m2, the number of channel bars developing doubled from 12 to 24. At vegetation densities greater than 150 plants/m2 there was a decline in the number of bars created to a minimum of 8 bars for a density of 400 plants/m2. We attribute these patterns to the effect that the vegetation has on flow hydraulics, sediment transport processes and the spatial patterns of erosion and deposition. We

  10. Dynamical arrest in dense short-ranged attractive colloids

    International Nuclear Information System (INIS)

    Foffi, G; Sciortino, F; Zaccarelli, E; Tartaglia, P

    2004-01-01

    We study thermodynamic and dynamic properties of model colloidal systems interacting with a hard core repulsion and a short-range attraction, and provide an overall picture of their phase diagrams which shows a very rich phenomenology. We focus on the slow dynamic properties of this model, investigating in detail the glass transition lines (both repulsive and attractive), the glass-glass transitions and the location of the higher order singularities. We discuss the relative location of the glass lines and of the metastable liquid-gas binodal, an issue relevant for the understanding of low density arrested states of matter

  11. Smartphone apps for spinal surgery: is technology good or evil?

    Science.gov (United States)

    Robertson, Greg A J; Wong, Seng Juong; Brady, Richard R; Subramanian, Ashok S

    2016-05-01

    The increased utilization of smartphones together with their downloadable applications (apps) provides opportunity for doctors, including spinal surgeons, to integrate such technology into clinical practice. However, the clinical reliability of the medical app sector remains questionable. We reviewed available apps themed specifically towards spinal surgery and related conditions and assessed the level of medical professional involvement in their design and content. The most popular smartphone app stores (Android, Apple, Blackberry, Windows, Samsung, Nokia) were searched for spinal surgery-themed apps, using the disease terms Spinal Surgery, Back Surgery, Spine, Disc Prolapse, Sciatica, Radiculopathy, Spinal Stenosis, Scoliosis, Spinal Fracture and Spondylolisthesis. A total of 78 individual spinal surgery themed apps were identified, of which there were six duplicates (N = 72). According to app store classifications, there were 57 (79 %) medical themed apps, 11 (15 %) health and fitness themed apps, 1 (1 %) business and 3 (4 %) education themed apps. Forty-five (63 %) apps were available for download free of charge. For those that charged access, the prices ranged from £0.62 to £47.99. Only 44 % of spinal surgery apps had customer satisfaction ratings and 56 % had named medical professional involvement in their development or content. This is the first study to specifically address the characteristics of apps related to spinal surgery. We found that nearly half of spinal surgery apps had no named medical professional involvement, raising concerns over app content and evidence base for their use. We recommend increased regulation of spinal surgical apps to improve the accountability of app content.

  12. Exploring the dynamics of phase separation in colloid-polymer mixtures with long range attraction.

    Science.gov (United States)

    Sabin, Juan; Bailey, Arthur E; Frisken, Barbara J

    2016-06-28

    We have studied the kinetics of phase separation and gel formation in a low-dispersity colloid - non-adsorbing polymer system with long range attraction using small-angle light scattering. This system exhibits two-phase and three-phase coexistence of gas, liquid and crystal phases when the strength of attraction is between 2 and 4kBT and gel phases when the strength of attraction is increased. For those samples that undergo macroscopic phase separation, whether to gas-crystal, gas-liquid or gas-liquid-crystal coexistence, we observe dynamic scaling of the structure factor and growth of a characteristic length scale that behaves as expected for phase separation in fluids. In samples that gel, the power law associated with the growth of the dominant length scale is not equal to 1/3, but appears to depend mainly on the strength of attraction, decreasing from 1/3 for samples near the coexistence region to 1/27 at 8kBT, over a wide range of colloid and polymer concentrations.

  13. Radiological diagnosis of chronic spinal cord compressive lesion at thoraco-lumbar junction

    Energy Technology Data Exchange (ETDEWEB)

    Koyanagi, Izumi; Isu, Toyohiko; Iwasaki, Yoshinobu; Akino, Minoru; Abe, Hiroshi; Tashiro, Kunio; Miyasaka, Kazuo; Abe, Satoru; Kaneda, Kiyoshi

    1988-10-01

    Radiological findings in five cases with chronic spinal cord compressive lesion at thoraco-lumbar junction were reported. Three cases had spondylosis and two cases had ossification of yellow ligament (OYL). The levels of the lesions were T12/L1 in three cases and T11/12 in two cases. Two out of three spondylotic patients had also OYL at the same level. The five cases consisted of three men and two women. The ages ranged from 42 to 60 years old with a mean age of 53 years old. Neurologically, every patient showed flaccid paresis and sensory disturbance of the legs. Two cases had sensory disturbance of stocking type. The intervals from the onset of the symptoms to the final diagnosis were 6 months, 7 years, 8 years, 11 years and 12 years. Myelography showed anterior spinal cord compression by bony spur in spondylotic patients, and posterior compression by OYL in other cases. Myelography in flexion posture disclosed the cord compression by bony spur more clearly in two out of three spondylotic patients. Delayed CT-myelography showed intramedullary filling of contrast material in two cases, which indicated degenerative change or microcavitation due to long term compression of the spinal cord. MRI was taken in three spondylotic patients and could directly show compression of the spinal cord. Difficulty in detecting abnormality at thoraco-lumbar junction on plain roentgenogram, and similarity of the symptoms to peripheral nerve disease often lead to a delay in diagnosis. The significance of dynamic myelography and delayed CT-myelography when dealing with such a lesion was discussed here. MRI is also a useful method for diagnosing a compressive lesion at the thoraco-lumbar junction.

  14. Radiological diagnosis of chronic spinal cord compressive lesion at thoraco-lumbar junction

    International Nuclear Information System (INIS)

    Koyanagi, Izumi; Isu, Toyohiko; Iwasaki, Yoshinobu; Akino, Minoru; Abe, Hiroshi; Tashiro, Kunio; Miyasaka, Kazuo; Abe, Satoru; Kaneda, Kiyoshi

    1988-01-01

    Radiological findings in five cases with chronic spinal cord compressive lesion at thoraco-lumbar junction were reported. Three cases had spondylosis and two cases had ossification of yellow ligament (OYL). The levels of the lesions were T12/L1 in three cases and T11/12 in two cases. Two out of three spondylotic patients had also OYL at the same level. The five cases consisted of three men and two women. The ages ranged from 42 to 60 years old with a mean age of 53 years old. Neurologically, every patient showed flaccid paresis and sensory disturbance of the legs. Two cases had sensory disturbance of stocking type. The intervals from the onset of the symptoms to the final diagnosis were 6 months, 7 years, 8 years, 11 years and 12 years. Myelography showed anterior spinal cord compression by bony spur in spondylotic patients, and posterior compression by OYL in other cases. Myelography in flexion posture disclosed the cord compression by bony spur more clearly in two out of three spondylotic patients. Delayed CT-myelography showed intramedullary filling of contrast material in two cases, which indicated degenerative change or microcavitation due to long term compression of the spinal cord. MRI was taken in three spondylotic patients and could directly show compression of the spinal cord. Difficulty in detecting abnormality at thoraco-lumbar junction on plain roentgenogram, and similarity of the symptoms to peripheral nerve disease often lead to a delay in diagnosis. The significance of dynamic myelography and delayed CT-myelography when dealing with such a lesion was discussed here. MRI is also a useful method for diagnosing a compressive lesion at the thoraco-lumbar junction. (author)

  15. Penetrating spinal injuries and their management

    Directory of Open Access Journals (Sweden)

    A Kumar

    2011-01-01

    Full Text Available Penetrating spinal trauma due to missile/gunshot injuries has been well reported in the literature and has remained the domain of military warfare more often. Civic society′s recent upsurge in gunshot injuries has created a dilemma for the treating neurosurgeon in many ways as their management has always involved certain debatable and controversial issues. Both conservative and surgical management of penetrating spinal injuries (PSI have been practiced widely. The chief neurosurgical concern in these types of firearm injuries is the degree of damage sustained during the bullet traversing through the neural tissue and the after-effects of the same in long term. We had an interesting case of a penetrating bullet injury to cervical spine at C2 vertebral level. He was operated and the bullets were removed from posterior midline approach. Usually, the management of such cases differs from region to region depending on the preference of the surgeon but still certain common principles are followed world over. Thus, we realized the need to review the literature regarding spinal injuries with special emphasis on PSI and to study the recent guidelines for their treatment in light of our case.

  16. Determination of boron over a large dynamic range by prompt-gamma activation analysis

    International Nuclear Information System (INIS)

    Harrison, R.K.; Landsberger, S.

    2009-01-01

    An evaluation of the PGAA method for the determination of boron across a wide dynamic range of concentrations was performed for trace levels up to 5 wt.% boron. This range encompasses a transition from neutron transparency to significant self- shielding conditions. To account for self-shielding, several PGAA techniques were employed. First, a calibration curve was developed in which a set of boron standards was tested and the count rate to boron mass curve was determined. This set of boron measurements was compared with an internal standard self-shielding correction method and with a method for determining composition using PGAA peak ratios. The advantages and disadvantages of each method are analyzed. The boron concentrations of several laboratory-grade chemicals and standard reference materials were measured with each method and compared. The evaluation of the boron content of nanocrystalline transition metals prepared with a boron-containing reducing agent was also performed with each of the methods tested. Finally, the k 0 method was used for non-destructive measurement of boron in catalyst materials for the characterization of new non-platinum fuel cell catalysts.

  17. Regional differences in radiosensitivity across the rat cervical spinal cord

    International Nuclear Information System (INIS)

    Bijl, Hendrik P.; Luijk, Peter van; Coppes, Rob P.; Schippers, Jacobus M.; Konings, Antonius W.T.; Kogel, Albert J. van der

    2005-01-01

    Purpose: To study regional differences in radiosensitivity within the rat cervical spinal cord. Methods and materials: Three types of inhomogeneous dose distributions were applied to compare the radiosensitivity of the lateral and central parts of the rat cervical spinal cord. The left lateral half of the spinal cord was irradiated with two grazing proton beams, each with a different penumbra (20-80% isodoses): lateral wide (penumbra = 1.1 mm) and lateral tight (penumbra = 0.8 mm). In the third experiment, the midline of the cord was irradiated with a narrow proton beam with a penumbra of 0.8 mm. The irradiated spinal cord length (CT-2) was 20 mm in all experiments. The animals were irradiated with variable single doses of unmodulated protons (150 MeV) with the shoot-through method, whereby the plateau of the depth-dose profile is used rather than the Bragg peak. The endpoint for estimating isoeffective dose (ED 50 ) values was paralysis of fore and/or hind limbs within 210 days after irradiation. Histology of the spinal cords was performed to assess the radiation-induced tissue damage. Results: High-precision proton irradiation of the lateral or the central part of the spinal cord resulted in a shift of dose-response curves to higher dose values compared with the homogeneously irradiated cervical cord to the same 20-mm length. The ED 50 values were 28.9 Gy and 33.4 Gy for the lateral wide and lateral tight irradiations, respectively, and as high as 71.9 Gy for the central beam experiment, compared with 20.4 Gy for the homogeneously irradiated 20-mm length of cervical cord. Histologic analysis of the spinal cords showed that the paralysis was due to white matter necrosis. The radiosensitivity was inhomogeneously distributed across the spinal cord, with a much more radioresistant central white matter (ED 50 = 71.9 Gy) compared with lateral white matter (ED 50 values = 28.9 Gy and 33.4 Gy). The gray matter did not show any noticeable lesions, such as necrosis or

  18. Hierarchical tone mapping for high dynamic range image visualization

    Science.gov (United States)

    Qiu, Guoping; Duan, Jiang

    2005-07-01

    In this paper, we present a computationally efficient, practically easy to use tone mapping techniques for the visualization of high dynamic range (HDR) images in low dynamic range (LDR) reproduction devices. The new method, termed hierarchical nonlinear linear (HNL) tone-mapping operator maps the pixels in two hierarchical steps. The first step allocates appropriate numbers of LDR display levels to different HDR intensity intervals according to the pixel densities of the intervals. The second step linearly maps the HDR intensity intervals to theirs allocated LDR display levels. In the developed HNL scheme, the assignment of LDR display levels to HDR intensity intervals is controlled by a very simple and flexible formula with a single adjustable parameter. We also show that our new operators can be used for the effective enhancement of ordinary images.

  19. Care of post-traumatic spinal cord injury patients in India: An analysis

    Directory of Open Access Journals (Sweden)

    Pandey V

    2007-01-01

    Full Text Available Background: The spinal cord injured patients if congregated early in spinal units where better facilities and dedicated expert care exist the outcome of treatment and rehabilitation, can be improved. The objective of this study is to find out the various factors responsible for a delay in the presentation of spinal injury patients to the specialized spinal trauma units and to suggest steps to improve the quality of care of the spinal trauma patients in the Indian setup. Materials and Methods: Sixty patients of traumatic spinal cord injury admitted for rehabilitation between August 2005 and May 2006 were enrolled into the study and their data was analyzed. Results: Eighty-five per cent of the spinal cord injured patients were males and the mean age was 34 years (range 13-56 years. Twenty-nine (48.33% of the spinal injuries occurred due to fall from height. There was an average of 45 days (range 0-188 days of delay in presentation to a specialized spinal unit and most of the time the cause for the delay was unawareness on the part of patients and/or doctors regarding specialized spinal units. In 38 (62.5% cases the mode of transportation of the spinal cord injured patient to the first visited hospital was by their own conveyance and the attendants of the patients did not have any idea about precautions essential to prevent neurological deterioration. Seventeen (28.33% patients were given injection solumedrol with conservative treatment, 35 (60% patients were given only conservative treatment and seven patients were operated (11.66% upon at initially visited hospital. Of the seven patients operated five were fixed with posterior Harrington instrumentation (71.42% and two (28.57% were operated by short segment posterior pedicle screw fixation. None of the patients were subjected to physiotherapy-assisted transfers or wheel chair skills or even basic postural training, proper bladder/ bowel training program and sitting balance. Conclusion: Awareness

  20. Stereotactic Body Radiation Therapy in Spinal Metastases

    International Nuclear Information System (INIS)

    Ahmed, Kamran A.; Stauder, Michael C.; Miller, Robert C.; Bauer, Heather J.; Rose, Peter S.; Olivier, Kenneth R.; Brown, Paul D.; Brinkmann, Debra H.; Laack, Nadia N.

    2012-01-01

    Purpose: Based on reports of safety and efficacy, stereotactic body radiotherapy (SBRT) for treatment of malignant spinal tumors was initiated at our institution. We report prospective results of this population at Mayo Clinic. Materials and Methods: Between April 2008 and December 2010, 85 lesions in 66 patients were treated with SBRT for spinal metastases. Twenty-two lesions (25.8%) were treated for recurrence after prior radiotherapy (RT). The mean age of patients was 56.8 ± 13.4 years. Patients were treated to a median dose of 24 Gy (range, 10–40 Gy) in a median of three fractions (range, 1–5). Radiation was delivered with intensity-modulated radiotherapy (IMRT) and prescribed to cover 80% of the planning target volume (PTV) with organs at risk such as the spinal cord taking priority over PTV coverage. Results: Tumor sites included 48, 22, 12, and 3 in the thoracic, lumbar, cervical, and sacral spine, respectively. The mean actuarial survival at 12 months was 52.2%. A total of 7 patients had both local and marginal failure, 1 patient experienced marginal but not local failure, and 1 patient had local failure only. Actuarial local control at 1 year was 83.3% and 91.2% in patients with and without prior RT. The median dose delivered to patients who experienced local/marginal failure was 24 Gy (range, 18–30 Gy) in a median of three fractions (range, 1–5). No cases of Grade 4 toxicity were reported. In 1 of 2 patients experiencing Grade 3 toxicity, SBRT was given after previous radiation. Conclusion: The results indicate SBRT to be an effective measure to achieve local control in spinal metastases. Toxicity of treatment was rare, including those previously irradiated. Our results appear comparable to previous reports analyzing spine SBRT. Further research is needed to determine optimum dose and fractionation to further improve local control and prevent toxicity.

  1. Magnetic Resonance Imaging Assessment of Spinal Cord and Cauda Equina Motion in Supine Patients With Spinal Metastases Planned for Spine Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Tseng, Chia-Lin [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Sussman, Marshall S. [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Atenafu, Eshetu G. [Department of Biostatistics, University Health Network, University of Toronto, Toronto, Ontario (Canada); Letourneau, Daniel [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Ma, Lijun [Department of Radiation Oncology, University of California San Francisco, San Francisco, California (United States); Soliman, Hany; Thibault, Isabelle [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Cho, B. C. John; Simeonov, Anna [Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada); Yu, Eugene [Department of Medical Imaging, University Health Network, University of Toronto, Toronto, Ontario (Canada); Fehlings, Michael G. [Department of Neurosurgery and Spine Program, Toronto Western Hospital, University of Toronto, Toronto, Ontario (Canada); Sahgal, Arjun, E-mail: arjun.sahgal@sunnybrook.ca [Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Princess Margaret Cancer Centre, University of Toronto, Toronto, Ontario (Canada)

    2015-04-01

    Purpose: To assess motion of the spinal cord and cauda equina, which are critical neural tissues (CNT), which is important when evaluating the planning organ-at-risk margin required for stereotactic body radiation therapy. Methods and Materials: We analyzed CNT motion in 65 patients with spinal metastases (11 cervical, 39 thoracic, and 24 lumbar spinal segments) in the supine position using dynamic axial and sagittal magnetic resonance imaging (dMRI, 3T Verio, Siemens) over a 137-second interval. Motion was segregated according to physiologic cardiorespiratory oscillatory motion (characterized by the average root mean square deviation) and random bulk shifts associated with gross patient motion (characterized by the range). Displacement was evaluated in the anteroposterior (AP), lateral (LR), and superior-inferior (SI) directions by use of a correlation coefficient template matching algorithm, with quantification of random motion measure error over 3 separate trials. Statistical significance was defined according to P<.05. Results: In the AP, LR, and SI directions, significant oscillatory motion was observed in 39.2%, 35.1%, and 10.8% of spinal segments, respectively, and significant bulk motions in all cases. The median oscillatory CNT motions in the AP, LR, and SI directions were 0.16 mm, 0.17 mm, and 0.44 mm, respectively, and the maximal statistically significant oscillatory motions were 0.39 mm, 0.41 mm, and 0.77 mm, respectively. The median bulk displacements in the AP, LR, and SI directions were 0.51 mm, 0.59 mm, and 0.66 mm, and the maximal statistically significant displacements were 2.21 mm, 2.87 mm, and 3.90 mm, respectively. In the AP, LR, and SI directions, bulk displacements were greater than 1.5 mm in 5.4%, 9.0%, and 14.9% of spinal segments, respectively. No significant differences in axial motion were observed according to cord level or cauda equina. Conclusions: Oscillatory CNT motion was observed to be relatively minor. Our results

  2. An abundance of small exoplanets around stars with a wide range of metallicities

    DEFF Research Database (Denmark)

    Buchhave, Lars A.; Latham, David W.; Johansen, Anders

    2012-01-01

    of the host stars of 226 small exoplanet candidates discovered by NASAs Kepler mission, including objects that are comparable in size to the terrestrial planets in the Solar System. We find that planets with radii less than four Earth radii form around host stars with a wide range of metallicities (but...

  3. A sub-circuit MOSFET model with a wide temperature range including cryogenic temperature

    Energy Technology Data Exchange (ETDEWEB)

    Jia Kan; Sun Weifeng; Shi Longxing, E-mail: jiakan.01@gmail.com [National ASIC System Engineering Research Center, Southeast University, Nanjing 210096 (China)

    2011-06-15

    A sub-circuit SPICE model of a MOSFET for low temperature operation is presented. Two resistors are introduced for the freeze-out effect, and the explicit behavioral models are developed for them. The model can be used in a wide temperature range covering both cryogenic temperature and regular temperatures. (semiconductor devices)

  4. Chronic spinal subdural hematoma; Spinales chronisches subdurales Haematom

    Energy Technology Data Exchange (ETDEWEB)

    Hagen, T.; Lensch, T. [Radiologengemeinschaft, Augsburg (Germany)

    2008-10-15

    Compared with spinal epidural hematomas, spinal subdural hematomas are rare; chronic forms are even more uncommon. These hematomas are associated not only with lumbar puncture and spinal trauma, but also with coagulopathies, vascular malformations and tumors. Compression of the spinal cord and the cauda equina means that the patients develop increasing back or radicular pain, followed by paraparesis and bladder and bowel paralysis, so that in most cases surgical decompression is carried out. On magnetic resonance imaging these hematomas present as thoracic or lumbar subdural masses, their signal intensity varying with the age of the hematoma. We report the clinical course and the findings revealed by imaging that led to the diagnosis in three cases of chronic spinal subdural hematoma. (orig.) [German] Spinale subdurale Haematome sind im Vergleich zu epiduralen Haematomen selten, chronische Verlaufsformen noch seltener. Ursaechlich sind neben Lumbalpunktionen und traumatischen Verletzungen auch Blutgerinnungsstoerungen, Gefaessmalformationen und Tumoren. Aufgrund der Kompression von Myelon und Cauda equina kommt es zu zunehmenden Ruecken- oder radikulaeren Schmerzen mit anschliessender Paraparese sowie einer Darm- und Blasenstoerung, weshalb in den meisten Faellen eine operative Entlastung durchgefuehrt wird. Magnetresonanztomographisch stellen sich die Haematome meist als thorakale bzw. lumbale subdurale Raumforderungen dar, die Signalintensitaet variiert mit dem Blutungsalter. Wir berichten ueber den klinischen Verlauf und die bildgebende Diagnostik von 3 Patienten mit spinalen chronischen subduralen Haematomen. (orig.)

  5. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Cord Injury What is a Spinal Cord Injury Levels of Injury and What They Mean Animated Spinal ... Cord Injury What is a Spinal Cord Injury Levels of Injury and What They Mean Animated Spinal ...

  6. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Injury Chart Spinal Cord Injury Facts and Figures Care and Treatment After SCI Spinal Cord Injury Rehabilitation ... Injury Chart Spinal Cord Injury Facts and Figures Care and Treatment After SCI Spinal Cord Injury Rehabilitation ...

  7. Spinal Cord Diseases

    Science.gov (United States)

    Your spinal cord is a bundle of nerves that runs down the middle of your back. It carries signals back ... of the spine, this can also injure the spinal cord. Other spinal cord problems include Tumors Infections such ...

  8. Spinal segmental dysgenesis

    Directory of Open Access Journals (Sweden)

    N Mahomed

    2009-06-01

    Full Text Available Spinal segmental dysgenesis is a rare congenital spinal abnormality , seen in neonates and infants in which a segment of the spine and spinal cord fails to develop normally . The condition is segmental with normal vertebrae above and below the malformation. This condition is commonly associated with various abnormalities that affect the heart, genitourinary, gastrointestinal tract and skeletal system. We report two cases of spinal segmental dysgenesis and the associated abnormalities.

  9. A high resolution large dynamic range TDC circuit implementation

    International Nuclear Information System (INIS)

    Lei Wuhu; Liu Songqiu; Ye Weiguo; Han Hui; Li Pengyu

    2003-01-01

    Time measurement technology is usually used in nuclear experimentation. There are many methods of time measurement. The implementation method of Time to Digital Conversion (TDC) by means of electronic is a classical technology. The range and resolution of TDC is different according with different usage. A wide range and high resolution TDC circuit, including its theory and implementation way, is introduced in this paper. The test result is also given. (authors)

  10. A high resolution large dynamic range TDC circuit implementation

    International Nuclear Information System (INIS)

    Lei Wuhu; Liu Songqiu; Li Pengyu; Han Hui; Ye Yanlin

    2005-01-01

    Time measurement technology is usually used in nuclear experimentation. There are many methods of time measurement. The implementation method of Time to Digital Conversion (TDC) by means of electronics is a classical technology. The range and resolution of TDC is different according with different usage. A wide range and high resolution TDC circuit, including its theory and implementation way, is introduced in this paper. The test result is also given. (authors)

  11. Quantitative high dynamic range beam profiling for fluorescence microscopy

    International Nuclear Information System (INIS)

    Mitchell, T. J.; Saunter, C. D.; O’Nions, W.; Girkin, J. M.; Love, G. D.

    2014-01-01

    Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences

  12. Atrophy and Primary Somatosensory Cortical Reorganization after Unilateral Thoracic Spinal Cord Injury: A Longitudinal Functional Magnetic Resonance Imaging Study

    Directory of Open Access Journals (Sweden)

    Jia-Sheng Rao

    2013-01-01

    Full Text Available The effects of traumatic spinal cord injury (SCI on the changes in the central nervous system (CNS over time may depend on the dynamic interaction between the structural integrity of the spinal cord and the capacity of the brain plasticity. Functional magnetic resonance imaging (fMRI was used in a longitudinal study on five rhesus monkeys to observe cerebral activation during upper limb somatosensory tasks in healthy animals and after unilateral thoracic SCI. The changes in the spinal cord diameters were measured, and the correlations among time after the lesion, structural changes in the spinal cord, and primary somatosensory cortex (S1 reorganization were also determined. After SCI, activation of the upper limb in S1 shifted to the region which generally dominates the lower limb, and the rostral spinal cord transverse diameter adjacent to the lesion exhibited obvious atrophy, which reflects the SCI-induced changes in the CNS. A significant correlation was found among the time after the lesion, the spinal cord atrophy, and the degree of contralateral S1 reorganization. The results indicate the structural changes in the spinal cord and the dynamic reorganization of the cerebral activation following early SCI stage, which may help to further understand the neural plasticity in the CNS.

  13. Dynamic Changes in Nociception and Pain Perception After Spinal Cord Stimulation in Chronic Neuropathic Pain Patients.

    Science.gov (United States)

    Biurrun Manresa, José A; Sörensen, Jan; Andersen, Ole K; Arendt-Nielsen, Lars; Gerdle, Björn

    2015-12-01

    Patients with an implanted spinal cord stimulation (SCS) system for pain management present an opportunity to study dynamic changes in the pain system in a situation where patients are not stimulated (ie, experiencing severe pain) compared with a situation in which patients have just been stimulated (ie, pain free or greatly reduced pain). The aims of this study were (1) to determine if there are differences in nociceptive withdrawal reflex thresholds (NWR-T) and electrical pain thresholds (EP-T) before and after SCS; and (2) to establish if these differences are related to psychological factors associated with chronic pain. Seventeen volunteers with chronic neuropathic pain participated in the experiment. Electrical stimuli were applied to assess the NWR-T and the EP-T. In addition, psychological factors (ie, pain characteristics, depression, anxiety, and disability indexes) were also recorded. The NWR-T and EP-T were assessed with the SCS system off (at least 8 h before the experiment), and then reassessed 1 hour after the SCS system was turned on. Ongoing pain intensity ratings decreased (P=0.018), whereas the NWR-T increased (P=0.028) after the SCS was turned on, whereas no significant difference was found for EP-T (P=0.324). Psychological factors were significant predictors for EP-T but not for NWR-T. The results of this study suggest that pain relief after SCS is partially mediated by a decrease in the excitability of dorsal horn neurons in the spinal cord.

  14. Hyperacute spinal subdural haematoma as a complication of lumbar spinal anaesthesia: MRI

    International Nuclear Information System (INIS)

    Pedraza Gutierrez, S.; Suescun, M.; Rovira Canellas, A.; Coll Masfarre, S.; Castano Duque, C.H.

    1999-01-01

    We report two cases of hyperacute spinal subdural haematoma secondary to lumbar spinal anaesthesia, identified with MRI. Prompt diagnosis of this infrequent, potentially serious complication of spinal anaesthesia is essential, as early surgical evacuation may be needed. Suggestive MRI findings in this early phase include diffuse occupation filling of the spinal canal with poor delineation of the spinal cord on T1-weighted images, and a poorly-defined high-signal lesion with a low-signal rim on T2-weighted images. (orig.)

  15. Neuroprotection and its molecular mechanism following spinal cord injury☆

    Science.gov (United States)

    Liu, Nai-Kui; Xu, Xiao-Ming

    2012-01-01

    Acute spinal cord injury initiates a complex cascade of molecular events termed ‘secondary injury’, which leads to progressive degeneration ranging from early neuronal apoptosis at the lesion site to delayed degeneration of intact white matter tracts, and, ultimately, expansion of the initial injury. These secondary injury processes include, but are not limited to, inflammation, free radical-induced cell death, glutamate excitotoxicity, phospholipase A2 activation, and induction of extrinsic and intrinsic apoptotic pathways, which are important targets in developing neuroprotective strategies for treatment of spinal cord injury. Recently, a number of studies have shown promising results on neuroprotection and recovery of function in rodent models of spinal cord injury using treatments that target secondary injury processes including inflammation, phospholipase A2 activation, and manipulation of the PTEN-Akt/mTOR signaling pathway. The present review outlines our ongoing research on the molecular mechanisms of neuroprotection in experimental spinal cord injury and briefly summarizes our earlier findings on the therapeutic potential of pharmacological treatments in spinal cord injury. PMID:25624837

  16. MRI findings of spinal visceral larva migrans of Toxocara canis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Ho, E-mail: leeinho1974@hanmail.ne [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Department of Radiology, Chungnam National University Hospital, 33 Munhwa-ro, Jung-gu, Daejeon 301-721 (Korea, Republic of); Kim, Sung Tae, E-mail: st7.kim@hotmail.co [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Oh, Dae Kun, E-mail: odk6464@nate.co [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Kim, Hyung-Jin, E-mail: hyungkim@skku.ed [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Kim, Keon Ha, E-mail: somatom@skku.ed [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Jeon, Pyoung, E-mail: drpjeon@gmail.co [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of); Byun, Hong Sik, E-mail: byun5474@skku.ed [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Ilwon-dong, Gangnam-Gu, Seoul 135-710 (Korea, Republic of)

    2010-08-15

    Purpose: The purpose of this study is to investigate the MRI findings of visceral larva migrans (VLS) of Toxocara canis in spinal cord. Materials and methods: We retrospectively reviewed spinal MRI findings in eight patients with serologically proven Toxocara canis between 2005 and 2008. We evaluated the location, length, extent and migration of the lesion, MR signal intensity (SI), enhancement pattern, and swelling of the spinal cord. We evaluated clinical features including presenting symptoms and signs and treatment response. Results: Total 8 patients (M = 8; age range 36-79 years) were included. The lesions were located in the cervical or thoracic spinal cord in all patients. All lesions showed high SI and minimal or mild swelling of involved spinal cord on T2WI and focal nodular enhancement on posterior or posterolateral segment of spinal cord. The length of involved lesion was relatively short in most patients. There was a migration of lesion in one patient. In spite of albendazole or steroid treatment, neurological symptoms or signs were not significantly improved in all patients. Conclusion: Although all lesions show non-specific imaging findings like non-tumorous myelopathy mimicking transverse myelitis, single lesion, focal nodular enhancement on posterior or posterolateral segment of spinal cord, relatively short segmental involvement and migration of lesion may be characteristic findings of spinal VLM of Toxocara canis. In addition, the reluctant response to the treatment may be characteristic of spinal VLM of Toxocara canis.

  17. MRI findings of spinal visceral larva migrans of Toxocara canis

    International Nuclear Information System (INIS)

    Lee, In Ho; Kim, Sung Tae; Oh, Dae Kun; Kim, Hyung-Jin; Kim, Keon Ha; Jeon, Pyoung; Byun, Hong Sik

    2010-01-01

    Purpose: The purpose of this study is to investigate the MRI findings of visceral larva migrans (VLS) of Toxocara canis in spinal cord. Materials and methods: We retrospectively reviewed spinal MRI findings in eight patients with serologically proven Toxocara canis between 2005 and 2008. We evaluated the location, length, extent and migration of the lesion, MR signal intensity (SI), enhancement pattern, and swelling of the spinal cord. We evaluated clinical features including presenting symptoms and signs and treatment response. Results: Total 8 patients (M = 8; age range 36-79 years) were included. The lesions were located in the cervical or thoracic spinal cord in all patients. All lesions showed high SI and minimal or mild swelling of involved spinal cord on T2WI and focal nodular enhancement on posterior or posterolateral segment of spinal cord. The length of involved lesion was relatively short in most patients. There was a migration of lesion in one patient. In spite of albendazole or steroid treatment, neurological symptoms or signs were not significantly improved in all patients. Conclusion: Although all lesions show non-specific imaging findings like non-tumorous myelopathy mimicking transverse myelitis, single lesion, focal nodular enhancement on posterior or posterolateral segment of spinal cord, relatively short segmental involvement and migration of lesion may be characteristic findings of spinal VLM of Toxocara canis. In addition, the reluctant response to the treatment may be characteristic of spinal VLM of Toxocara canis.

  18. Wide Input Range Power Converters Using a Variable Turns Ratio Transformer

    DEFF Research Database (Denmark)

    Ouyang, Ziwei; Andersen, Michael A. E.

    2016-01-01

    A new integrated transformer with variable turns ratio is proposed to enable dc-dc converters operating over a wide input voltage range. The integrated transformer employs a new geometry of magnetic core with “four legs”, two primary windings with orthogonal arrangement, and “8” shape connection...... of diagonal secondary windings, in order to make the transformer turns ratio adjustable by controlling the phase between the two current excitations subjected to the two primary windings. Full-bridge boost dc-dc converter is employed with the proposed transformer to demonstrate the feasibility of the variable...

  19. MULTIPLE SPINAL CANAL MENINGIOMAS

    Directory of Open Access Journals (Sweden)

    Nandigama Pratap Kumar

    2016-10-01

    Full Text Available BACKGROUND Meningiomas of the spinal canal are common tumours with the incidence of 25 percent of all spinal cord tumours. But multiple spinal canal meningiomas are rare in compare to solitary lesions and account for 2 to 3.5% of all spinal meningiomas. Most of the reported cases are both intra cranial and spinal. Exclusive involvement of the spinal canal by multiple meningiomas are very rare. We could find only sixteen cases in the literature to the best of our knowledge. Exclusive multiple spinal canal meningiomas occurring in the first two decades of life are seldom reported in the literature. We are presenting a case of multiple spinal canal meningiomas in a young patient of 17 years, who was earlier operated for single lesion. We analysed the literature, with illustration of our case. MATERIALS AND METHODS In September 2016, we performed a literature search for multiple spinal canal meningiomas involving exclusively the spinal canal with no limitation for language and publication date. The search was conducted through http://pubmed.com, a wellknown worldwide internet medical address. To the best of our knowledge, we could find only sixteen cases of multiple meningiomas exclusively confined to the spinal canal. Exclusive multiple spinal canal meningiomas occurring in the first two decades of life are seldom reported in the literature. We are presenting a case of multiple spinal canal meningiomas in a young patient of 17 years, who was earlier operated for solitary intradural extra medullary spinal canal meningioma at D4-D6 level, again presented with spastic quadriparesis of two years duration and MRI whole spine demonstrated multiple intradural extra medullary lesions, which were excised completely and the histopathological diagnosis was transitional meningioma. RESULTS Patient recovered from his weakness and sensory symptoms gradually and bladder and bowel symptoms improved gradually over a period of two to three weeks. CONCLUSION Multiple

  20. Estimating indices of range shifts in birds using dynamic models when detection is imperfect

    Science.gov (United States)

    Clement, Matthew J.; Hines, James E.; Nichols, James D.; Pardieck, Keith L.; Ziolkowski, David J.

    2016-01-01

    There is intense interest in basic and applied ecology about the effect of global change on current and future species distributions. Projections based on widely used static modeling methods implicitly assume that species are in equilibrium with the environment and that detection during surveys is perfect. We used multiseason correlated detection occupancy models, which avoid these assumptions, to relate climate data to distributional shifts of Louisiana Waterthrush in the North American Breeding Bird Survey (BBS) data. We summarized these shifts with indices of range size and position and compared them to the same indices obtained using more basic modeling approaches. Detection rates during point counts in BBS surveys were low, and models that ignored imperfect detection severely underestimated the proportion of area occupied and slightly overestimated mean latitude. Static models indicated Louisiana Waterthrush distribution was most closely associated with moderate temperatures, while dynamic occupancy models indicated that initial occupancy was associated with diurnal temperature ranges and colonization of sites was associated with moderate precipitation. Overall, the proportion of area occupied and mean latitude changed little during the 1997–2013 study period. Near-term forecasts of species distribution generated by dynamic models were more similar to subsequently observed distributions than forecasts from static models. Occupancy models incorporating a finite mixture model on detection – a new extension to correlated detection occupancy models – were better supported and may reduce bias associated with detection heterogeneity. We argue that replacing phenomenological static models with more mechanistic dynamic models can improve projections of future species distributions. In turn, better projections can improve biodiversity forecasts, management decisions, and understanding of global change biology.

  1. Brain-wide neuronal dynamics during motor adaptation in zebrafish.

    Science.gov (United States)

    Ahrens, Misha B; Li, Jennifer M; Orger, Michael B; Robson, Drew N; Schier, Alexander F; Engert, Florian; Portugues, Ruben

    2012-05-09

    A fundamental question in neuroscience is how entire neural circuits generate behaviour and adapt it to changes in sensory feedback. Here we use two-photon calcium imaging to record the activity of large populations of neurons at the cellular level, throughout the brain of larval zebrafish expressing a genetically encoded calcium sensor, while the paralysed animals interact fictively with a virtual environment and rapidly adapt their motor output to changes in visual feedback. We decompose the network dynamics involved in adaptive locomotion into four types of neuronal response properties, and provide anatomical maps of the corresponding sites. A subset of these signals occurred during behavioural adjustments and are candidates for the functional elements that drive motor learning. Lesions to the inferior olive indicate a specific functional role for olivocerebellar circuitry in adaptive locomotion. This study enables the analysis of brain-wide dynamics at single-cell resolution during behaviour.

  2. Designing double-gap linear accelerators for a wide mass range

    International Nuclear Information System (INIS)

    Lysenko, W.P.; Wadlinger, E.A.; Rusnak, B.; Krawczyk, F.; Saadatmand, K.; Wan, Z.

    1998-01-01

    For applications like ion implantation, rf linacs using double-gap structures with external resonators can be used because they are practical at low frequencies. However, since the two gaps associated with a given resonator cannot be individually phased, it is not obvious how to build a linac that can efficiently accelerate particles having different mass/charge ratios. This paper describes the beam dynamics of double-gap rf linacs and shows how to maximize the range of mass/charge ratios. The theory also tells one how to rescale a linac tune (i.e., reset the voltages and phases) so that a new particle, having a different mass or charge, will behave similarly to the original particle

  3. Precise digital integration in wide time range: theory and realization

    International Nuclear Information System (INIS)

    Batrakov, A.M.; Pavlenko, A.V.

    2017-01-01

    The digital integration method based on using high-speed precision analog-to-digital converters (ADC) has become widely used over the recent years. The paper analyzes the limitations of this method that are caused by the signal properties, ADC sampling rate and noise spectral density of the ADC signal path. This analysis allowed creating digital integrators with accurate synchronization and achieving an integration error of less than 10 −5 in the time range from microseconds to tens of seconds. The structure of the integrator is described and its basic parameters are presented. The possibilities of different ADC chips in terms of their applicability to digital integrators are discussed. A comparison with other integrating devices is presented.

  4. Image Alignment for Multiple Camera High Dynamic Range Microscopy.

    Science.gov (United States)

    Eastwood, Brian S; Childs, Elisabeth C

    2012-01-09

    This paper investigates the problem of image alignment for multiple camera high dynamic range (HDR) imaging. HDR imaging combines information from images taken with different exposure settings. Combining information from multiple cameras requires an alignment process that is robust to the intensity differences in the images. HDR applications that use a limited number of component images require an alignment technique that is robust to large exposure differences. We evaluate the suitability for HDR alignment of three exposure-robust techniques. We conclude that image alignment based on matching feature descriptors extracted from radiant power images from calibrated cameras yields the most accurate and robust solution. We demonstrate the use of this alignment technique in a high dynamic range video microscope that enables live specimen imaging with a greater level of detail than can be captured with a single camera.

  5. Resource selection and its implications for wide-ranging mammals of the brazilian cerrado.

    Science.gov (United States)

    Vynne, Carly; Keim, Jonah L; Machado, Ricardo B; Marinho-Filho, Jader; Silveira, Leandro; Groom, Martha J; Wasser, Samuel K

    2011-01-01

    Conserving animals beyond protected areas is critical because even the largest reserves may be too small to maintain viable populations for many wide-ranging species. Identification of landscape features that will promote persistence of a diverse array of species is a high priority, particularly, for protected areas that reside in regions of otherwise extensive habitat loss. This is the case for Emas National Park, a small but important protected area located in the Brazilian Cerrado, the world's most biologically diverse savanna. Emas Park is a large-mammal global conservation priority area but is too small to protect wide-ranging mammals for the long-term and conserving these populations will depend on the landscape surrounding the park. We employed novel, noninvasive methods to determine the relative importance of resources found within the park, as well as identify landscape features that promote persistence of wide-ranging mammals outside reserve borders. We used scat detection dogs to survey for five large mammals of conservation concern: giant armadillo (Priodontes maximus), giant anteater (Myrmecophaga tridactyla), maned wolf (Chrysocyon brachyurus), jaguar (Panthera onca), and puma (Puma concolor). We estimated resource selection probability functions for each species from 1,572 scat locations and 434 giant armadillo burrow locations. Results indicate that giant armadillos and jaguars are highly selective of natural habitats, which makes both species sensitive to landscape change from agricultural development. Due to the high amount of such development outside of the Emas Park boundary, the park provides rare resource conditions that are particularly important for these two species. We also reveal that both woodland and forest vegetation remnants enable use of the agricultural landscape as a whole for maned wolves, pumas, and giant anteaters. We identify those features and their landscape compositions that should be prioritized for conservation, arguing

  6. Resource selection and its implications for wide-ranging mammals of the brazilian cerrado.

    Directory of Open Access Journals (Sweden)

    Carly Vynne

    Full Text Available Conserving animals beyond protected areas is critical because even the largest reserves may be too small to maintain viable populations for many wide-ranging species. Identification of landscape features that will promote persistence of a diverse array of species is a high priority, particularly, for protected areas that reside in regions of otherwise extensive habitat loss. This is the case for Emas National Park, a small but important protected area located in the Brazilian Cerrado, the world's most biologically diverse savanna. Emas Park is a large-mammal global conservation priority area but is too small to protect wide-ranging mammals for the long-term and conserving these populations will depend on the landscape surrounding the park. We employed novel, noninvasive methods to determine the relative importance of resources found within the park, as well as identify landscape features that promote persistence of wide-ranging mammals outside reserve borders. We used scat detection dogs to survey for five large mammals of conservation concern: giant armadillo (Priodontes maximus, giant anteater (Myrmecophaga tridactyla, maned wolf (Chrysocyon brachyurus, jaguar (Panthera onca, and puma (Puma concolor. We estimated resource selection probability functions for each species from 1,572 scat locations and 434 giant armadillo burrow locations. Results indicate that giant armadillos and jaguars are highly selective of natural habitats, which makes both species sensitive to landscape change from agricultural development. Due to the high amount of such development outside of the Emas Park boundary, the park provides rare resource conditions that are particularly important for these two species. We also reveal that both woodland and forest vegetation remnants enable use of the agricultural landscape as a whole for maned wolves, pumas, and giant anteaters. We identify those features and their landscape compositions that should be prioritized for

  7. Evaluation of a short dynamic 18F-fluoride PET/CT scanning method to assess bone metabolic activity in spinal orthopedics.

    Science.gov (United States)

    Peters, Marloes J M; Wierts, Roel; Jutten, Elisabeth M C; Halders, Servé G E A; Willems, Paul C P H; Brans, Boudewijn

    2015-11-01

    A complication after spinal fusion surgery is pseudarthrosis, but its radiological diagnosis is of limited value. (18)F-fluoride PET with its ability to assess bone metabolism activity could be of value. The goal of this study was to assess the clinical feasibility of calculating the static standardized uptake value (SUV) from a short dynamic scan without the use of blood sampling, thereby obtaining all dynamic and static parameters in a scan of only 30 min. This approach was tested on a retrospective patient population with persisting pain after spinal fusion surgery. In 16 patients, SUVs (SUV max, SUV mean) and kinetic parameters (K 1, k 2, k 3, v b, K i,NLR, K 1/k 2, k 3/(k 2 + k 3), K i,patlak) were derived from static and dynamic PET/CT scans of operated and control regions of the spine, after intravenous administration of 156-214 MBq (18)F-fluoride. Parameter differences between control and operated regions, as well as between pseudarthrosis and fused segments were evaluated. SUVmean at 30 and 60 min was calculated from kinetic parameters obtained from the dynamic data set (SUV mean,2TCM). Agreement between measured and calculated SUVs was evaluated through Bland-Altman plots. Overall, statistically significant differences between control and operated regions were observed for SUV max, SUV mean, K i,NLR, K i,patlak, K 1/k 2 and k 3/(k 2 + k 3). Diagnostic CT showed pseudarthrosis in 6/16 patients, while in 10/16 patients, segments were fused. Of all parameters, only those regarding the incorporation of bone [K i,NLR, K i,patlak, k 3/(k 2 + k 3)] differed statistically significant in the intervertebral disc space between the pseudarthrosis and fused patients group. The mean values of the patient-specific blood clearance rate [Formula: see text] differed statistically significant between the pseudarthrosis and the fusion group, with a p value of 0.011. This may correspond with the lack of statistical significance of the SUV values between pseudarthrosis and

  8. Spinal sagittal imbalance in patients with lumbar disc herniation: its spinopelvic characteristics, strength changes of the spinal musculature and natural history after lumbar discectomy.

    Science.gov (United States)

    Liang, Chen; Sun, Jianmin; Cui, Xingang; Jiang, Zhensong; Zhang, Wen; Li, Tao

    2016-07-22

    Spinal sagittal imbalance is a widely acknowledged problem, but there is insufficient knowledge regarding its occurrence. In some patients with lumbar disc herniation (LDH), their symptom is similar to spinal sagittal imbalance. The aim of this study is to illustrate the spinopelvic sagittal characteristics and identity the role of spinal musculature in the mechanism of sagittal imbalance in patients with LDH. Twenty-five adults with spinal sagittal imbalance who initially came to our clinic for treatment of LDH, followed by posterior discectomy were reviewed. The horizontal distance between C7 plumb line-sagittal vertical axis (C7PL-SVA) greater than 5 cm anteriorly with forward bending posture is considered as spinal sagittal imbalance. Radiographic parameters including thoracic kyphotic angle (TK), lumbar lordotic angle (LL), pelvic tilting angle (PT), sacral slope angle (SS) and an electromyography(EMG) index 'the largest recruitment order' were recorded and compared. All patients restored coronal and sagittal balance immediately after lumbar discectomy. The mean C7PL-SVA and trunk shift value decreased from (11.6 ± 6.6 cm, and 2.9 ± 6.1 cm) preoperatively to (-0.5 ± 2.6 cm and 0.2 ± 0.5 cm) postoperatively, while preoperative LL and SS increased from (25.3° ± 14.0° and 25.6° ± 9.5°) to (42.4° ± 10.2° and 30.4° ± 8.7°) after surgery (P imbalance caused by LDH is one type of compensatory sagittal imbalance. Compensatory mechanism of spinal sagittal imbalance mainly includes a loss of lumbar lordosis, an increase of thoracic kyphosis and pelvis tilt. Spinal musculature plays an important role in spinal sagittal imbalance in patients with LDH.

  9. Development and regulation of response properties in spinal cord motoneurons

    DEFF Research Database (Denmark)

    Perrier, J F; Hounsgaard, J

    2000-01-01

    The intrinsic response properties of spinal motoneurons determine how converging premotor neuronal input is translated into the final motor command transmitted to muscles. From the patchy data available it seems that these properties and their underlying currents are highly conserved in terrestrial...... vertebrates in terms of both phylogeny and ontogeny. Spinal motoneurons in adults are remarkably similar in many respects ranging from the resting membrane potential to pacemaker properties. Apart from the axolotls, spinal motoneurons from all species investigated have latent intrinsic response properties...... mediated by L-type Ca2+ channels. This mature phenotype is reached gradually during development through phases in which A-type potassium channels and T-type calcium channels are transiently expressed. The intrinsic response properties of mature spinal motoneurons are subject to short-term adjustments via...

  10. Spinal Cord Injuries

    Science.gov (United States)

    ... forth between your body and your brain. A spinal cord injury disrupts the signals. Spinal cord injuries usually begin with a blow that fractures or ... down on the nerve parts that carry signals. Spinal cord injuries can be complete or incomplete. With a complete ...

  11. Does Motor Development in Infancy Predict Spinal Pain in Later Childhood?

    DEFF Research Database (Denmark)

    Kamper, Steven J; Williams, Christopher M; Hestbaek, Lise

    2017-01-01

    Study Design Longitudinal cohort study. Background Spinal pain is responsible for a huge personal and societal burden but the aetiology remains unclear. Deficits in motor control have been implicated with spinal pain in adults, and delayed motor development is associated with a range of health...... a child first sits or walks without support does not influence the likelihood that they will experience spinal pain in later childhood. Level of Evidence Etiology 2b. J Orthop Sports Phys Ther, Epub 15 Sep 2017. doi:10.2519/jospt.2017.7484....

  12. Luminescence of high density electron-hole plasma in CdS and CdSe in a wide temperature range

    International Nuclear Information System (INIS)

    Yoshida, H.; Shionoya, S.

    1983-01-01

    Time-resolved spectra of the spontaneous luminescence of the high density electron-hole plasma (EHP) in CdS and CdSe are observed in a wide range of temperature which is surely higher than the calculated critical temperature for electron-hole liquid formation, in order to carry forward discussion on dynamic nature of the EHP previously observed in 4.2 K experiments. Spectra in the late stage are analyzed, and obtained values of the reduced bandgap energy and chemical potential are compared with those theoretically calculated for higher temperatures. The aspects of the change of the spectral shape in the late stage are hard to understand. Unfortunately no clear conclusion is drawn on the nature of the EHP produced at 4.2 K. The only thing one can say is that the condensed electron-hole liquid state, which is in equilibrium with the exciton state, is not realized. (author)

  13. QUANTITATIVE SIZE ASSESSMENT OF THE LUMBAR SPINAL CANAL BY COMPUTED TOMOGRAPHY

    Directory of Open Access Journals (Sweden)

    M. Midia Z. Miabi

    2007-08-01

    Full Text Available By determining normal ranges of spinal canal diameters we can make early diagnosis in persons who have lower diameters of spinal canal. These persons are predisposed to spinal canal stenosis that is a major cause of spinal radiculopathies. In different studies performed in several countries, minimum and maximum ranges of spinal canal diameters were different for each population. In this study, we tried to determine the mean values of normal spinal canal diameters and areas in Tabriz and its suburb. 39 healthy, young to mid-age cases were selected. Our study was focused on L3-L4 and L4-L5. The following parameters were measured: the area of cross-section of the vertebral body, the area of cross-section of the dural sac, interarticular diameter, interligamentous diameter, antero-posterior diameter of the lumbar canal, inter-pedicular diameter, and the area of cross-section of the vertebral canal. A correlation between the parameters studied and the height of subjects was significant for interligamentous diameter (for L3/L4 and L4/L5 and interarticular diameter (only at L3/L4, cross-section area of the vertebrae (both L3 and L4, cross-section area of vertebral canal (only at L5 level, area of dural sac (at L3/L4 and L4. It was suggested that these diameters and areas should be interpreted as a unction of height of the subject. Most of diameters studied had smaller means than those in previous studies. This can be attributed to differences between populations and it can be interpreted as predisposition to spinal canal stenosis in our population.

  14. Probing the role of long-range interactions in the dynamics of a long-range Kitaev chain

    Science.gov (United States)

    Dutta, Anirban; Dutta, Amit

    2017-09-01

    We study the role of long-range interactions (more precisely, the long-range superconducting gap term) on the nonequilibrium dynamics considering a long-range p -wave superconducting chain in which the superconducting term decays with distance between two sites in a power-law fashion characterized by an exponent α . We show that the Kibble-Zurek scaling exponent, dictating the power-law decay of the defect density in the final state reached following a slow (in comparison to the time scale associated with the minimum gap in the spectrum of the Hamiltonian) quenching of the chemical potential μ across a quantum critical point, depends nontrivially on the exponent α as long as α 2 , we find that the exponent saturates to the corresponding well-known value of 1 /2 expected for the short-range model. Furthermore, studying the dynamical quantum phase transitions manifested in the nonanalyticities in the rate function of the return possibility I (t ) in subsequent temporal evolution following a sudden change in μ , we show the existence of a new region; in this region, we find three instants of cusp singularities in I (t ) associated with a single sector of Fisher zeros. Notably, the width of this region shrinks as α increases and vanishes in the limit α →2 , indicating that this special region is an artifact of the long-range nature of the Hamiltonian.

  15. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Abuse and Spinal Cord Injury Allen Heinemann, PhD How Peer Counseling Works Julie Gassaway, MS, RN Pediatric Injuries Pediatric Spinal ... What is a spinal cord injury? play_arrow How does the spinal cord work? play_arrow Why is the level of a ...

  16. Distributing flight dynamics products via the World Wide Web

    Science.gov (United States)

    Woodard, Mark; Matusow, David

    1996-01-01

    The NASA Flight Dynamics Products Center (FDPC), which make available selected operations products via the World Wide Web, is reported on. The FDPC can be accessed from any host machine connected to the Internet. It is a multi-mission service which provides Internet users with unrestricted access to the following standard products: antenna contact predictions; ground tracks; orbit ephemerides; mean and osculating orbital elements; earth sensor sun and moon interference predictions; space flight tracking data network summaries; and Shuttle transport system predictions. Several scientific data bases are available through the service.

  17. Radiation tolerance of the cervical spinal cord

    International Nuclear Information System (INIS)

    McCunniff, A.J.; Liang, M.J.

    1989-01-01

    The incidence of permanent injury to the spinal cord as a complication of radiation therapy generally correlates positively with total radiation dosage. However, several reports in the literature have indicated that fraction size is also an important factor in the development or nondevelopment of late injuries in normal tissue. To determine the effect of fraction size on the incidence of radiation-induced spinal cord injuries, we reviewed 144 cases of head and neck cancer treated at our institution between 1971 and 1980 with radiation greater than 5600 cGy to a portion of the cervical spinal cord. Most of these patients received greater than or equal to 6000 cGy, with fraction sizes ranging from 133 cGy to 200 cGy. Fifty-three of the 144 patients have been followed up for 2 years or more. Nearly half of these (26 patients) received greater than 6000 cGy with fraction sizes of 133 cGy to 180 cGy. Only 1 of the 53 (1.9%) has sustained permanent spinal cord injury; 20 months after completion of radiation treatments he developed Brown-Sequard syndrome. Our experience suggests that radiation injuries to the spinal cord correlate not only with total radiation dosage, but also with fraction size; low fraction sizes appear to decrease the incidence of such injuries

  18. Role of allografts in spinal surgery

    International Nuclear Information System (INIS)

    Aziz Nather

    1999-01-01

    With development of more tissue banks in the region and internationally, allografts are increasingly being used in orthopaedic surgery including spinal surgery. Two groups of patients will particularly benefit from the use of allografts. The first group is young children in whom iliac crest is cartilaginous and cannot provide sufficient quantity of autografts. The second is the elderly where bones from iliac crest are porotic and fatty. Allografts are used to fulfill two distinct functions in Spinal Surgery. One is to act as a buttress for anterior spinal surgery using cortical allografts. The other is to enhance fusion for posterior spinal surgery. Up to December 1997, 71 transplantations have been performed using allografts from NUH Tissue Bank. Anterior Spinal Surgery has been performed in 15 cases. The indications are mainly Trauma-Burst Fractures and Spinal Secondaries to the Spine. All cases are in thoracic and thoracolumbar region. Allografts used are deep frozen and freeze-dried cortical allografts. Femur is used for thoraco-lumbar region and humerus for upper thoracic region. Instrumentation used ranged from anterior devices (Canada, DCP, Synergy etc) to posterior devices (ISOLA). Deep frozen allografts and more recently freeze-dried allografts are preferred especially for osteoporotic spines. Cortical allografts are packed with autografts from ribs in the medullary canal. Allograft-autograft composites are always used to ensure better incorporation. Postero-lateral fusion has been performed for 56 cases. The indications include congenital and idiopathic scoliosis, degenerative stenosis, degenerative spondylolisthesis, spondylolytic spondylolisthesis, fracture-dislocation, osteoporotic burst fracture, spinal secondaries with cord compression and traumatic spondylolisthesis. Deep frozen bone allografts are used in combination with patient's own autografts from spinous processes to provide a 50% mix. Instrumentation used include Hartshill, Steffee, Isola

  19. International Spinal Cord Injury

    DEFF Research Database (Denmark)

    Dvorak, M F; Itshayek, E; Fehlings, M G

    2015-01-01

    STUDY DESIGN: Survey of expert opinion, feedback and final consensus. OBJECTIVE: To describe the development and the variables included in the International Spinal Cord Injury (SCI) Spinal Interventions and Surgical Procedures Basic Data set. SETTING: International working group. METHODS......: A committee of experts was established to select and define data elements. The data set was then disseminated to the appropriate committees and organizations for comments. All suggested revisions were considered and both the International Spinal Cord Society and the American Spinal Injury Association endorsed...... spinal intervention and procedure is coded (variables 1 through 7) and the spinal segment level is described (variables 8 and 9). Sample clinical cases were developed to illustrate how to complete it. CONCLUSION: The International SCI Spinal Interventions and Surgical Procedures Basic Data Set...

  20. Increasing Linear Dynamic Range of a CMOS Image Sensor

    Science.gov (United States)

    Pain, Bedabrata

    2007-01-01

    A generic design and a corresponding operating sequence have been developed for increasing the linear-response dynamic range of a complementary metal oxide/semiconductor (CMOS) image sensor. The design provides for linear calibrated dual-gain pixels that operate at high gain at a low signal level and at low gain at a signal level above a preset threshold. Unlike most prior designs for increasing dynamic range of an image sensor, this design does not entail any increase in noise (including fixed-pattern noise), decrease in responsivity or linearity, or degradation of photometric calibration. The figure is a simplified schematic diagram showing the circuit of one pixel and pertinent parts of its column readout circuitry. The conventional part of the pixel circuit includes a photodiode having a small capacitance, CD. The unconventional part includes an additional larger capacitance, CL, that can be connected to the photodiode via a transfer gate controlled in part by a latch. In the high-gain mode, the signal labeled TSR in the figure is held low through the latch, which also helps to adapt the gain on a pixel-by-pixel basis. Light must be coupled to the pixel through a microlens or by back illumination in order to obtain a high effective fill factor; this is necessary to ensure high quantum efficiency, a loss of which would minimize the efficacy of the dynamic- range-enhancement scheme. Once the level of illumination of the pixel exceeds the threshold, TSR is turned on, causing the transfer gate to conduct, thereby adding CL to the pixel capacitance. The added capacitance reduces the conversion gain, and increases the pixel electron-handling capacity, thereby providing an extension of the dynamic range. By use of an array of comparators also at the bottom of the column, photocharge voltages on sampling capacitors in each column are compared with a reference voltage to determine whether it is necessary to switch from the high-gain to the low-gain mode. Depending upon

  1. High dynamic range vision sensor for automotive applications

    Science.gov (United States)

    Grenet, Eric; Gyger, Steve; Heim, Pascal; Heitger, Friedrich; Kaess, Francois; Nussbaum, Pascal; Ruedi, Pierre-Francois

    2005-02-01

    A 128 x 128 pixels, 120 dB vision sensor extracting at the pixel level the contrast magnitude and direction of local image features is used to implement a lane tracking system. The contrast representation (relative change of illumination) delivered by the sensor is independent of the illumination level. Together with the high dynamic range of the sensor, it ensures a very stable image feature representation even with high spatial and temporal inhomogeneities of the illumination. Dispatching off chip image feature is done according to the contrast magnitude, prioritizing features with high contrast magnitude. This allows to reduce drastically the amount of data transmitted out of the chip, hence the processing power required for subsequent processing stages. To compensate for the low fill factor (9%) of the sensor, micro-lenses have been deposited which increase the sensitivity by a factor of 5, corresponding to an equivalent of 2000 ASA. An algorithm exploiting the contrast representation output by the vision sensor has been developed to estimate the position of a vehicle relative to the road markings. The algorithm first detects the road markings based on the contrast direction map. Then, it performs quadratic fits on selected kernel of 3 by 3 pixels to achieve sub-pixel accuracy on the estimation of the lane marking positions. The resulting precision on the estimation of the vehicle lateral position is 1 cm. The algorithm performs efficiently under a wide variety of environmental conditions, including night and rainy conditions.

  2. Addition of adenosine to hyperbaric bupivacaine in spinal ...

    African Journals Online (AJOL)

    2011-04-17

    Apr 17, 2011 ... cause sedation, hypotension and bradycardia. Intrathecal neostigmine may ... in spinal anaesthesia does not prolong postoperative analgesia in vaginal .... Values are mean ± standard deviation (range). Number of patients.

  3. Spinal cysts. Diagnostic workup and therapy; Spinale Zysten. Diagnostik und Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Simgen, A. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2018-02-15

    Spinal cysts can be classified as meningeal, not meningeal, and tumor-associated cysts. Due to the widespread availability of high-resolution computed tomography and magnet resonance imaging, spinal cysts can be detected with high sensitivity these days. Concerning the variety of potential cystic differential diagnoses, a precise classification is difficult and can often only be realized after surgical inspection or histological examination. Spinal cysts are generally incidental findings during a routine diagnostic workup and need no further therapy. Surgical treatment can be necessary if the spinal cyst reaches a certain size and causes neurological symptoms due to the compression of the spinal cord or the nerve root. (orig.) [German] Spinale Zysten koennen in meningeale, nichtmeningeale und tumorassoziierte Zysten eingeteilt werden. Durch die weite Verbreitung von hochaufloesenden Computer- und Magnetresonanztomographen koennen spinale Zysten heutzutage mit einer hohen Sensitivitaet erkannt werden. Eine genaue Klassifikation kann sich unter der Vielzahl der moeglichen zystischen Differenzialdiagnosen schwierig gestalten und ist haeufig nur durch eine chirurgische Inspektion oder die histologische Untersuchung moeglich. Meistens werden spinale Zysten bei der Routinediagnostik als Zufallsbefunde entdeckt und benoetigen keine weitere Therapie. Erreichen sie allerdings eine gewisse Groesse, koennen sie raumfordernd auf das Myelon oder einzelne Nervenwurzeln wirken und somit ausgepraegte neurologische Symptome verursachen. In solchen Faellen ist ein chirurgisches Vorgehen zur Resektion einer spinalen Zyste notwendig. (orig.)

  4. Minimally Invasive Drainage of a Post-Laminectomy Subfascial Seroma with Cervical Spinal Cord Compression.

    Science.gov (United States)

    Kitshoff, Adriaan Mynhardt; Van Goethem, Bart; Cornelis, Ine; Combes, Anais; Dvm, Ingeborgh Polis; Gielen, Ingrid; Vandekerckhove, Peter; de Rooster, Hilde

    2016-01-01

    A 14 mo old female neutered Doberman pinscher was evaluated for difficulty in rising, a wide based stance, pelvic limb gait abnormalities, and cervical pain of 2 mo duration. Neurologic examination revealed pelvic limb ataxia and cervical spinal hyperesthesia. Spinal reflexes and cranial nerve examination were normal. The pathology was localized to the C1-C5 or C6-T2 spinal cord segments. Computed tomography (CT) findings indicated bony proliferation of the caudal articular processes of C6 and the cranial articular processes of C7, resulting in bilateral dorsolateral spinal cord compression that was more pronounced on the left side. A limited dorsal laminectomy was performed at C6-C7. Due to progressive neurological deterioration, follow-up CT examination was performed 4 days postoperatively. At the level of the laminectomy defect, a subfacial seroma had developed, entering the spinal canal and causing significant spinal cord compression. Under ultrasonographic guidance a closed-suction wound catheter was placed. Drainage of the seroma successfully relieved its compressive effects on the spinal cord and the patient's neurological status improved. CT was a valuable tool in assessing spinal cord compression as a result of a postoperative subfascial seroma. Minimally invasive application of a wound catheter can be successfully used to manage this condition.

  5. Low Power High Dynamic Range A/D Conversion Channel

    DEFF Research Database (Denmark)

    Marker-Villumsen, Niels; Rombach, Pirmin

    in the conversion channel in order to avoid distortion for large input signals. In combination with a low resolution A/D converter (ADC) and a digital gain block, the adaptive A/D conversion channel achieves an extended dynamic range beyond that of the ADC. This in turn reduces the current consumption......This work concerns the analysis of an adaptive analog-to-digital (A/D) conversion channel for use with a micro electromechanical system (MEMS) microphone for audio applications. The adaptive A/D conversion channel uses an automatic gain control (AGC) for adjusting the analog preamplifier gain...... of the conversion channel in comparison to a static A/D conversion channel; this at the cost of a reduced peak signal-to-noise ratio (SNR). The adaptive A/D conversion channel compensates for the change in analog gain by a digital gain, thus achieving a constant channel gain in the full dynamic range. However...

  6. Gamut mapping in a high-dynamic-range color space

    Science.gov (United States)

    Preiss, Jens; Fairchild, Mark D.; Ferwerda, James A.; Urban, Philipp

    2014-01-01

    In this paper, we present a novel approach of tone mapping as gamut mapping in a high-dynamic-range (HDR) color space. High- and low-dynamic-range (LDR) images as well as device gamut boundaries can simultaneously be represented within such a color space. This enables a unified transformation of the HDR image into the gamut of an output device (in this paper called HDR gamut mapping). An additional aim of this paper is to investigate the suitability of a specific HDR color space to serve as a working color space for the proposed HDR gamut mapping. For the HDR gamut mapping, we use a recent approach that iteratively minimizes an image-difference metric subject to in-gamut images. A psychophysical experiment on an HDR display shows that the standard reproduction workflow of two subsequent transformations - tone mapping and then gamut mapping - may be improved by HDR gamut mapping.

  7. Ionic mechanisms of spinal neuronal cold hypersensitivity in ciguatera.

    Science.gov (United States)

    Patel, Ryan; Brice, Nicola L; Lewis, Richard J; Dickenson, Anthony H

    2015-12-01

    Cold hypersensitivity is evident in a range of neuropathies and can evoke sensations of paradoxical burning cold pain. Ciguatoxin poisoning is known to induce a pain syndrome caused by consumption of contaminated tropical fish that can persist for months and include pruritus and cold allodynia; at present no suitable treatment is available. This study examined, for the first time, the neural substrates and molecular components of Pacific ciguatoxin-2-induced cold hypersensitivity. Electrophysiological recordings of dorsal horn lamina V/VI wide dynamic range neurones were made in non-sentient rats. Subcutaneous injection of 10 nm ciguatoxin-2 into the receptive field increased neuronal responses to innocuous and noxious cooling. In addition, neuronal responses to low-threshold but not noxious punctate mechanical stimuli were also elevated. The resultant cold hypersensitivity was not reversed by 6-({2-[2-fluoro-6-(trifluoromethyl)phenoxy]-2-methylpropyl}carbamoyl)pyridine-3-carboxylic acid, an antagonist of transient receptor potential melastatin 8 (TRPM8). Both mechanical and cold hypersensitivity were completely prevented by co-injection with the Nav 1.8 antagonist A803467, whereas the transient receptor potential ankyrin 1 (TRPA1) antagonist A967079 only prevented hypersensitivity to innocuous cooling and partially prevented hypersensitivity to noxious cooling. In naive rats, neither innocuous nor noxious cold-evoked neuronal responses were inhibited by antagonists of Nav 1.8, TRPA1 or TRPM8 alone. Ciguatoxins may confer cold sensitivity to a subpopulation of cold-insensitive Nav 1.8/TRPA1-positive primary afferents, which could underlie the cold allodynia reported in ciguatera. These data expand the understanding of central spinal cold sensitivity under normal conditions and the role of these ion channels in this translational rat model of ciguatoxin-induced hypersensitivity. © 2015 The Authors. European Journal of Neuroscience published by Federation of

  8. Does the application site of spinal manipulative therapy alter spinal tissues loading?

    Science.gov (United States)

    Funabashi, Martha; Nougarou, François; Descarreaux, Martin; Prasad, Narasimha; Kawchuk, Gregory N

    2018-01-31

    Previous studies found that the intervertebral disc (IVD) experiences the greatest loads during spinal manipulation therapy (SMT). Based on that, this study aimed to determine if loads experienced by spinal tissues are significantly altered when the application site of SMT is changed. A biomechanical robotic serial dissection study. Thirteen porcine cadaveric motion segments. Forces experienced by lumbar spinal tissues. A servo-controlled linear actuator provided standardized 300 N SMT simulations to six different cutaneous locations of the porcine lumbar spine: L2-L3 and L3-L4 facet joints (FJ), L3 and L4 transverse processes (TVP), and the space between the FJs and the TVPs (BTW). Vertebral kinematics were tracked optically using indwelling bone pins; the motion segment was removed and mounted in a parallel robot equipped with a six-axis load cell. Movements of each SMT application at each site were replayed by the robot with the intact specimen and following the sequential removal of spinal ligaments, FJs and IVD. Forces induced by SMT were recorded, and specific axes were analyzed using linear mixed models. Analyses yielded a significant difference (p<.05) in spinal structures loads as a function of the application site. Spinal manipulative therapy application at the L3 vertebra caused vertebral movements and forces between L3 and L4 spinal segment in the opposite direction to when SMT was applied at L4 vertebra. Additionally, SMT applications over the soft tissue between adjacent vertebrae significantly decreased spinal structure loads. Applying SMT with a constant force at different spinal levels creates different relative kinetics of the spinal segments and load spinal tissues in significantly different magnitudes. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Modern spinal instrumentation. Part 1: Normal spinal implants

    International Nuclear Information System (INIS)

    Davis, W.; Allouni, A.K.; Mankad, K.; Prezzi, D.; Elias, T.; Rankine, J.; Davagnanam, I.

    2013-01-01

    The general radiologist frequently encounters studies demonstrating spinal instrumentation, either as part of the patient's postoperative evaluation or as incidental to a study performed for another purpose. There are various surgical approaches and devices used in spinal surgery with an increased understanding of spinal and spinal implant biomechanics drives development of modern fixation devices. It is, therefore, important that the radiologist can recognize commonly used devices and identify their potential complications demonstrated on imaging. The aim of part 1 of this review is to familiarize the reader with terms used to describe surgical approaches to the spine, review the function and normal appearances of commonly used instrumentations, and understand the importance of the different fixation techniques. The second part of this review will concentrate on the roles that the different imaging techniques play in assessing the instrumented spine and the recognition of complications that can potentially occur.

  10. Modifications to JLab 12 GeV Refrigerator and Wide Range Mix Mode Performance Testing Results

    Science.gov (United States)

    Knudsen, P.; Ganni, V.; Hasan, N.; Dixon, K.; Norton, R.; Creel, J.

    2017-02-01

    Analysis of data obtained during the spring 2013 commissioning of the new 4.5 K refrigeration system at Jefferson Lab (JLab) for the 12 GeV upgrade indicated a wide capacity range with good efficiency and minimal operator interaction. Testing also showed that the refrigerator required higher liquid nitrogen (LN) consumption for its pre-cooler than anticipated by the design. This does not affect the capacity of the refrigerator, but it does result in an increased LN utility cost. During the summer of 2015 the modifications were implemented by the cold box manufacturer, according to a design similar to the JLab 12 GeV cold box specification. Subsequently, JLab recommissioned the cold box and performed extensive performance testing, ranging from 20% to 100% of the design maximum capacity, and in various modes of operation, ranging from pure refrigeration, pure liquefaction, half-and-half mix mode and at selected design modes using the Floating Pressure - Ganni Cycle. The testing demonstrated that the refrigerator system has a good and fairly constant performance over a wide capacity range and different modes of operation. It also demonstrated the modifications resulted in a LN consumption that met the design for the pure refrigeration mode (which is the most demanding) and was lower than the design for the nominal and maximum capacity modes. In addition, a pulsed-load test, similar to what is expected for cryogenic systems supporting fusion experiments, was conducted to observe the response using the Floating Pressure - Ganni Cycle, which was stable and robust. This paper will discuss the results and analysis of this testing pertaining to the LN consumption, the system efficiency over a wide range of capacity and different modes and the behaviour of the system to a pulsed load.

  11. Glioblastoma with spinal seeding

    International Nuclear Information System (INIS)

    Fakhrai, N.; Fazeny-Doerner, B.; Marosi, C.; Czech, T.; Diekmann, K.; Birner, P.; Hainfellner, J.A.; Prayer, D.

    2004-01-01

    Background: extracranial seeding of glioblastoma multiforme (GBM) is very rare and its development depends on several factors. This case report describes two patients suffering from GBM with spinal seeding. In both cases, the anatomic localization of the primary tumor close to the cerebrospinal fluid (CSF) was the main factor for spinal seeding. Case reports: two patients with GBM and spinal seeding are presented. After diagnosis of spinal seeding, both patients were highly symptomatic from their spinal lesions. Case 1 experienced severe pain requiring opiates, and case 2 had paresis of lower limbs as well as urinary retention/incontinence. Both patients were treated with spinal radiation therapy. Nevertheless, they died 3 months after diagnosis of spinal seeding. Results: in both patients the diagnosis of spinal seeding was made at the time of cranial recurrence. Both tumors showed close contact to the CSF initially. Even though the patients underwent intensive treatment, it was not possible to keep them in a symptom-free state. Conclusion: because of short survival periods, patients deserve optimal pain management and dedicated palliative care. (orig.)

  12. Glioblastoma with spinal seeding

    Energy Technology Data Exchange (ETDEWEB)

    Fakhrai, N.; Fazeny-Doerner, B.; Marosi, C. [Clinical Div. of Oncology, Dept. of Medicine I, Univ. of Vienna (Austria); Czech, T. [Dept. of Neurosurgery, Univ. of Vienna (Austria); Diekmann, K. [Dept. of Radiooncology, Univ. of Vienna (Austria); Birner, P.; Hainfellner, J.A. [Clinical Inst. for Neurology, Univ. of Vienna (Austria); Prayer, D. [Dept. of Neuroradiology, Univ. of Vienna (Austria)

    2004-07-01

    Background: extracranial seeding of glioblastoma multiforme (GBM) is very rare and its development depends on several factors. This case report describes two patients suffering from GBM with spinal seeding. In both cases, the anatomic localization of the primary tumor close to the cerebrospinal fluid (CSF) was the main factor for spinal seeding. Case reports: two patients with GBM and spinal seeding are presented. After diagnosis of spinal seeding, both patients were highly symptomatic from their spinal lesions. Case 1 experienced severe pain requiring opiates, and case 2 had paresis of lower limbs as well as urinary retention/incontinence. Both patients were treated with spinal radiation therapy. Nevertheless, they died 3 months after diagnosis of spinal seeding. Results: in both patients the diagnosis of spinal seeding was made at the time of cranial recurrence. Both tumors showed close contact to the CSF initially. Even though the patients underwent intensive treatment, it was not possible to keep them in a symptom-free state. Conclusion: because of short survival periods, patients deserve optimal pain management and dedicated palliative care. (orig.)

  13. Clustering of quasars in a wide luminosity range at redshift 4 with Subaru Hyper Suprime-Cam Wide-field imaging

    Science.gov (United States)

    He, Wanqiu; Akiyama, Masayuki; Bosch, James; Enoki, Motohiro; Harikane, Yuichi; Ikeda, Hiroyuki; Kashikawa, Nobunari; Kawaguchi, Toshihiro; Komiyama, Yutaka; Lee, Chien-Hsiu; Matsuoka, Yoshiki; Miyazaki, Satoshi; Nagao, Tohru; Nagashima, Masahiro; Niida, Mana; Nishizawa, Atsushi J.; Oguri, Masamune; Onoue, Masafusa; Oogi, Taira; Ouchi, Masami; Schulze, Andreas; Shirasaki, Yuji; Silverman, John D.; Tanaka, Manobu M.; Tanaka, Masayuki; Toba, Yoshiki; Uchiyama, Hisakazu; Yamashita, Takuji

    2018-01-01

    We examine the clustering of quasars over a wide luminosity range, by utilizing 901 quasars at \\overline{z}_phot˜ 3.8 with -24.73 Strategic Program (HSC-SSP) S16A Wide2 date release and 342 more luminous quasars at 3.4 Digital Sky Survey that fall in the HSC survey fields. We measure the bias factors of two quasar samples by evaluating the cross-correlation functions (CCFs) between the quasar samples and 25790 bright z ˜ 4 Lyman break galaxies in M1450 < -21.25 photometrically selected from the HSC dataset. Over an angular scale of 10.0" to 1000.0", the bias factors are 5.93+1.34-1.43 and 2.73+2.44-2.55 for the low- and high-luminosity quasars, respectively, indicating no significant luminosity dependence of quasar clustering at z ˜ 4. It is noted that the bias factor of the luminous quasars estimated by the CCF is smaller than that estimated by the auto-correlation function over a similar redshift range, especially on scales below 40.0". Moreover, the bias factor of the less-luminous quasars implies the minimal mass of their host dark matter halos is 0.3-2 × 1012 h-1 M⊙, corresponding to a quasar duty cycle of 0.001-0.06.

  14. Extending the dynamic range of silicon photomultipliers without increasing pixel count

    International Nuclear Information System (INIS)

    Johnson, Kurtis F.

    2010-01-01

    A silicon photomultiplier, sometimes called 'multipixel photon counter', which we here refer to as a 'SiPM', is a photo-sensitive device built from an avalanche photodiode array of pixels on a common silicon substrate, such that it can detect single photon events. The dimensions of a pixel may vary from 20 to 100 μm and their density can be greater than 1000 per square millimeter. Each pixel in a SiPM operates in Geiger mode and is coupled to the output by a quenching resistor. Although each pixel operates in digital mode, the SiPM is an analog device because all the pixels are read in parallel, making it possible to generate signals within a dynamic range from a single photon to a large number of photons, ultimately limited by the number of pixels on the chip. In this note we describe a simple and general method of increasing the dynamic range of a SiPM beyond that one may naively assume from the shape of the cumulative distribution function of the SiPM response to the average number of photons per pixel. We show that by rendering the incoming flux of photons to be non-uniform in a prescribed manner, a significant increase in dynamic range is achievable. Such re-distribution of the incoming flux may be accomplished with simple, non-focusing lenses, prisms, interference films, mirrors or attenuating films. Almost any optically non-inert interceding device can increase the dynamic range of the SiPM.

  15. Binaural model-based dynamic-range compression.

    Science.gov (United States)

    Ernst, Stephan M A; Kortlang, Steffen; Grimm, Giso; Bisitz, Thomas; Kollmeier, Birger; Ewert, Stephan D

    2018-01-26

    Binaural cues such as interaural level differences (ILDs) are used to organise auditory perception and to segregate sound sources in complex acoustical environments. In bilaterally fitted hearing aids, dynamic-range compression operating independently at each ear potentially alters these ILDs, thus distorting binaural perception and sound source segregation. A binaurally-linked model-based fast-acting dynamic compression algorithm designed to approximate the normal-hearing basilar membrane (BM) input-output function in hearing-impaired listeners is suggested. A multi-center evaluation in comparison with an alternative binaural and two bilateral fittings was performed to assess the effect of binaural synchronisation on (a) speech intelligibility and (b) perceived quality in realistic conditions. 30 and 12 hearing impaired (HI) listeners were aided individually with the algorithms for both experimental parts, respectively. A small preference towards the proposed model-based algorithm in the direct quality comparison was found. However, no benefit of binaural-synchronisation regarding speech intelligibility was found, suggesting a dominant role of the better ear in all experimental conditions. The suggested binaural synchronisation of compression algorithms showed a limited effect on the tested outcome measures, however, linking could be situationally beneficial to preserve a natural binaural perception of the acoustical environment.

  16. Autonomous Vehicles Have a Wide Range of Possible Energy Impacts (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Brown, A.; Repac, B.; Gonder, J.

    2013-07-01

    This poster presents initial estimates of the net energy impacts of automated vehicles (AVs). Automated vehicle technologies are increasingly recognized as having potential to decrease carbon dioxide emissions and petroleum consumption through mechanisms such as improved efficiency, better routing, lower traffic congestion, and by enabling advanced technologies. However, some effects of AVs could conceivably increase fuel consumption through possible effects such as longer distances traveled, increased use of transportation by underserved groups, and increased travel speeds. The net effect on petroleum use and climate change is still uncertain. To make an aggregate system estimate, we first collect best estimates for the energy impacts of approximately ten effects of AVs. We then use a modified Kaya Identity approach to estimate the range of aggregate effects and avoid double counting. We find that depending on numerous factors, there is a wide range of potential energy impacts. Adoption of automated personal or shared vehicles can lead to significant fuel savings but has potential for backfire.

  17. Precise predictions of H2O line shapes over a wide pressure range using simulations corrected by a single measurement

    Science.gov (United States)

    Ngo, N. H.; Nguyen, H. T.; Tran, H.

    2018-03-01

    In this work, we show that precise predictions of the shapes of H2O rovibrational lines broadened by N2, over a wide pressure range, can be made using simulations corrected by a single measurement. For that, we use the partially-correlated speed-dependent Keilson-Storer (pcsdKS) model whose parameters are deduced from molecular dynamics simulations and semi-classical calculations. This model takes into account the collision-induced velocity-changes effects, the speed dependences of the collisional line width and shift as well as the correlation between velocity and internal-state changes. For each considered transition, the model is corrected by using a parameter deduced from its broadening coefficient measured for a single pressure. The corrected-pcsdKS model is then used to simulate spectra for a wide pressure range. Direct comparisons of the corrected-pcsdKS calculated and measured spectra of 5 rovibrational lines of H2O for various pressures, from 0.1 to 1.2 atm, show very good agreements. Their maximum differences are in most cases well below 1%, much smaller than residuals obtained when fitting the measurements with the Voigt line shape. This shows that the present procedure can be used to predict H2O line shapes for various pressure conditions and thus the simulated spectra can be used to deduce the refined line-shape parameters to complete spectroscopic databases, in the absence of relevant experimental values.

  18. Clinical Outcome of Dose-Escalated Image-Guided Radiotherapy for Spinal Metastases

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Goebel, Joachim; Wilbert, Juergen; Baier, Kurt; Richter, Anne; Sweeney, Reinhart A.; Bratengeier, Klaus; Flentje, Michael

    2009-01-01

    Purpose: To evaluate the outcomes after dose-escalated radiotherapy (RT) for spinal metastases and paraspinal tumors. Methods and Materials: A total of 14 patients, 12 with spinal metastases and a long life expectancy and 2 with paraspinal tumors, were treated for 16 lesions with intensity-modulated, image-guided RT. A median biologic effective dose of 74 Gy 10 (range, 55-86) in a median of 20 fractions (range, 3-34) was prescribed to the target volume. The spinal canal was treated to 40 Gy in 20 fractions using a second intensity-modulated RT dose level in the case of epidural involvement. Results: After median follow-up of 17 months, one local recurrence was observed, for an actuarial local control rate of 88% after 2 years. Local control was associated with rapid and long-term pain relief. Of 11 patients treated for a solitary spinal metastasis, 6 developed systemic disease progression. The actuarial overall survival rate for metastatic patients was 85% and 63% after 1 and 2 years, respectively. Acute Grade 2-3 skin toxicity was seen in 2 patients with no late toxicity greater than Grade 2. No radiation-induced myelopathy was observed. Conclusion: Dose-escalated irradiation of spinal metastases was safe and resulted in excellent local control. Oligometastatic patients with a long life expectancy and epidural involvement are considered to benefit the most from fractionated RT.

  19. Long-range correlations and fractal dynamics in C. elegans: Changes with aging and stress

    Science.gov (United States)

    Alves, Luiz G. A.; Winter, Peter B.; Ferreira, Leonardo N.; Brielmann, Renée M.; Morimoto, Richard I.; Amaral, Luís A. N.

    2017-08-01

    Reduced motor control is one of the most frequent features associated with aging and disease. Nonlinear and fractal analyses have proved to be useful in investigating human physiological alterations with age and disease. Similar findings have not been established for any of the model organisms typically studied by biologists, though. If the physiology of a simpler model organism displays the same characteristics, this fact would open a new research window on the control mechanisms that organisms use to regulate physiological processes during aging and stress. Here, we use a recently introduced animal-tracking technology to simultaneously follow tens of Caenorhabdits elegans for several hours and use tools from fractal physiology to quantitatively evaluate the effects of aging and temperature stress on nematode motility. Similar to human physiological signals, scaling analysis reveals long-range correlations in numerous motility variables, fractal properties in behavioral shifts, and fluctuation dynamics over a wide range of timescales. These properties change as a result of a superposition of age and stress-related adaptive mechanisms that regulate motility.

  20. Diffuse radiation models and monthly-average, daily, diffuse data for a wide latitude range

    International Nuclear Information System (INIS)

    Gopinathan, K.K.; Soler, A.

    1995-01-01

    Several years of measured data on global and diffuse radiation and sunshine duration for 40 widely spread locations in the latitude range 36° S to 60° N are used to develop and test models for estimating monthly-mean, daily, diffuse radiation on horizontal surfaces. Applicability of the clearness-index (K) and sunshine fraction (SSO) models for diffuse estimation and the effect of combining several variables into a single multilinear equation are tested. Correlations connecting the diffuse to global fraction (HdH) with K and SSO predict Hd values more accurately than their separate use. Among clearness-index and sunshine-fraction models, SSO models are found to have better accuracy if correlations are developed for wide latitude ranges. By including a term for declinations in the correlation, the accuracy of the estimated data can be marginally improved. The addition of latitude to the equation does not help to improve the accuracy further. (author)

  1. Validity and reliability of the 10-m walk test and the 6-min walk test in spinal cord injury patients.

    Science.gov (United States)

    Scivoletto, G; Tamburella, F; Laurenza, L; Foti, C; Ditunno, J F; Molinari, M

    2011-06-01

    The 10-m walk test (10MWT) and the 6-min walk test (6MWT) have been recommended for assessment of walking in spinal cord injury (SCI) patients. The study was designed on test-retest analysis of the 10MWT and 6MWT. The objective of this study was to assess validity/reliability of different methods of performing the tests. The study was set at an SCI unit of a rehabilitation hospital. A total of 37 patients; whose median age was 58.5 years (interquartile range 40-66, full range 19-77); median time since onset of SCI was 24 months (interquartile range 16.25-70.5, full range 6-109). Non-traumatic etiology in 20 out of 37 patients; level: 12C, 14T and 11L; American Spinal Injury Association Impairment Scale grade: 35D/2C. Assessment with the 10MWT (with or without dynamic start) and the 6MWT (short or long track) by two blinded raters to evaluate inter/intra-rater reliabilities. The 10MWT was performed in a median of 19 s (25th-75th interquartile range 13-28) with the dynamic start and of 18.4 s (25th-75th interquartile range 12.6-29.9) with the static start (P=0.092). The correlation between the results of the two methods was between 0.98 and 0.99. The inter- and intra-rater reliabilities were between 0.95 and 0.99 for both the methods. The 6MWT showed significant differences according to the track length: patients walked a median of 226.7 m (25th-75th interquartile range 123.2-319) on the longer track and of 187.6 m (25th-75th interquartile range 69.7-240.6) on the short one (P<0.001). The correlation between the results of the two methods was between 0.91 and 0.93. The inter- and intra-rater reliabilities were between 0.98 and 0.99. The 10MWT shows high inter/intra-rater reliability and shows comparable results with both dynamic and static start. The different testing conditions of the 6MWT (track/turns) results in significant differences that need standardization for use in future trials.

  2. Human spinal motor control

    DEFF Research Database (Denmark)

    Nielsen, Jens Bo

    2016-01-01

    Human studies in the past three decades have provided us with an emerging understanding of how cortical and spinal networks collaborate to ensure the vast repertoire of human behaviors. We differ from other animals in having direct cortical connections to spinal motoneurons, which bypass spinal...... the central motor command by opening or closing sensory feedback pathways. In the future, human studies of spinal motor control, in close collaboration with animal studies on the molecular biology of the spinal cord, will continue to document the neural basis for human behavior. Expected final online...

  3. Cervical spondylosis with spinal cord encroachment: should preventive surgery be recommended?

    Directory of Open Access Journals (Sweden)

    Murphy Donald R

    2009-08-01

    Full Text Available Abstract Background It has been stated that individuals who have spondylotic encroachment on the cervical spinal cord without myelopathy are at increased risk of spinal cord injury if they experience minor trauma. Preventive decompression surgery has been recommended for these individuals. The purpose of this paper is to provide the non-surgical spine specialist with information upon which to base advice to patients. The evidence behind claims of increased risk is investigated as well as the evidence regarding the risk of decompression surgery. Methods A literature search was conducted on the risk of spinal cord injury in individuals with asymptomatic cord encroachment and the risk and benefit of preventive decompression surgery. Results Three studies on the risk of spinal cord injury in this population met the inclusion criteria. All reported increased risk. However, none were prospective cohort studies or case-control studies, so the designs did not allow firm conclusions to be drawn. A number of studies and reviews of the risks and benefits of decompression surgery in patients with cervical myelopathy were found, but no studies were found that addressed surgery in asymptomatic individuals thought to be at risk. The complications of decompression surgery range from transient hoarseness to spinal cord injury, with rates ranging from 0.3% to 60%. Conclusion There is insufficient evidence that individuals with spondylotic spinal cord encroachment are at increased risk of spinal cord injury from minor trauma. Prospective cohort or case-control studies are needed to assess this risk. There is no evidence that prophylactic decompression surgery is helpful in this patient population. Decompression surgery appears to be helpful in patients with cervical myelopathy, but the significant risks may outweigh the unknown benefit in asymptomatic individuals. Thus, broad recommendations for decompression surgery in suspected at-risk individuals cannot be made

  4. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Topic Resources Peer Counseling Blog About Media Donate Spinal Cord Injury Medical Expert Videos Topics menu Topics Spinal Cord Injury 101 Adult Injuries Spinal Cord Injury 101 ...

  5. Calcium dynamics and buffering in motoneurones of the mouse spinal cord

    Czech Academy of Sciences Publication Activity Database

    Paleček, Jiří; Lips, M. B.; Keller, B. U.

    1999-01-01

    Roč. 520, č. 2 (1999), s. 485-502 ISSN 0928-4257 R&D Projects: GA ČR(CZ) GA305/96/0680 Institutional research plan: CEZ:AV0Z5011922 Keywords : spinal cord * motor neuron toxicity * amyotrophic lateral sclerosis Subject RIV: FH - Neurology Impact factor: 1.130, year: 1999

  6. Spinal tumors

    International Nuclear Information System (INIS)

    Goethem, J.W.M. van; Hauwe, L. van den; Oezsarlak, Oe.; Schepper, A.M.A. de; Parizel, P.M.

    2004-01-01

    Spinal tumors are uncommon lesions but may cause significant morbidity in terms of limb dysfunction. In establishing the differential diagnosis for a spinal lesion, location is the most important feature, but the clinical presentation and the patient's age and gender are also important. Magnetic resonance (MR) imaging plays a central role in the imaging of spinal tumors, easily allowing tumors to be classified as extradural, intradural-extramedullary or intramedullary, which is very useful in tumor characterization. In the evaluation of lesions of the osseous spine both computed tomography (CT) and MR are important. We describe the most common spinal tumors in detail. In general, extradural lesions are the most common with metastasis being the most frequent. Intradural tumors are rare, and the majority is extramedullary, with meningiomas and nerve sheath tumors being the most frequent. Intramedullary tumors are uncommon spinal tumors. Astrocytomas and ependymomas comprise the majority of the intramedullary tumors. The most important tumors are documented with appropriate high quality CT or MR images and the characteristics of these tumors are also summarized in a comprehensive table. Finally we illustrate the use of the new World Health Organization (WHO) classification of neoplasms affecting the central nervous system

  7. MRI study on spinal canal content in Western Maharashtrian population

    Directory of Open Access Journals (Sweden)

    Khanapurkar SV, Kulkarni DO, Bahetee BH, Vahane MI

    2014-07-01

    Full Text Available The morphology of the spinal canal content has been studied since the invention of myelography. However, most studies have measured the diameters of the spinal cord only, not the size of the subarachnoid space. The present study complements the current data on the morphology of the spinal contents, and in particular, the spinal subarachnoid space, by analyzing MRI images. Objective: To study morphology of the dural sac, spinal cord & subarachnoid space using MRI. To define the inner geometrical dimensions of spinal canal content that confine the maneuver of an endoscope inserted in cervical spine. 3. To have comprehensive knowledge of the anatomy of cervical spinal canal. Method: Based on MRI images of the spine from 60 normal patients of age between 25-60 years, the dimensions of spinal cord, dural sac & subarachnoid space were measured at mid-vertebral & intervertebral level from C1-C7 vertebrae. The parameters measured were transverse, sagittal diameter of spinal cord & dural sac. The subarachnoid space was measured as anterior, posterior, right, left distance between spinal cord and dura mater. Results: It was found that at each selected transverse level, the subarachnoid space tends to be symmetrical on the right and left sides of the cord, and measures 3.38 mm on an average. However, the anterior and posterior segment, measured on the mid-sagittal plane are generally asymmetric & varies greatly in size ranging 1mm to 6mm with mean 2.57 of anterior & 2.59 of posterior. These measurements match those found in previous studies. The coefficient of variance for the dimensions of the subarachnoid space is as high as 36.16%, while that for the dimensions of the spinal cord (transverse & sagittal are11.08%&13.28%respectively. Conclusion: The findings presented here, expand our knowledge of morphology of spinal canal and show that a thecaloscope must be smaller than 3.38 mm in diameter.

  8. Sensitivity and Dynamic Range Considerations for Homodyne Detection Systems

    DEFF Research Database (Denmark)

    Jaggard, Dwight L.; King, Ray J

    1973-01-01

    The effects of modulation frequency, RF reference power, and external bias upon the sensitivity and dynamic range of microwave homodyne detection systems was measured for point contact diodes and low l/f noise Schottky and backward diodes. The measurements were made at 4.89 GHz using a signal...... to noise ratio of 3 dB and a detection system bandwidth of 10 Hz. Maximum sensitivities of -135, -150, and -145 dBm, and dynamic ranges of 92, 110, and 124 dB were measured for the point contact, Schottky, and backward diodes at modulation frequencies of 30, 30, and 3 kHz, respectively. It was found...... that the level of RF reference signal needed to obtain the maximum sensitivity was equal to or somewhat above the point where the diode changes from square law to linear detection. The results are significant in that previously reported homodyne sensitivities (not necessarily maximum) were on the order of -90...

  9. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Topic Resources Peer Counseling Blog About Media Donate Spinal Cord Injury Medical Expert Videos Topics menu Topics Spinal Cord Injury 101 Adult Injuries Spinal Cord Injury 101 David ...

  10. Thermal and dynamic range characterization of a photonics-based RF amplifier

    Science.gov (United States)

    Noque, D. F.; Borges, R. M.; Muniz, A. L. M.; Bogoni, A.; Cerqueira S., Arismar, Jr.

    2018-05-01

    This work reports a thermal and dynamic range characterization of an ultra-wideband photonics-based RF amplifier for microwave and mm-waves future 5G optical-wireless networks. The proposed technology applies the four-wave mixing nonlinear effect to provide RF amplification in analog and digital radio-over-fiber systems. The experimental analysis from 300 kHz to 50 GHz takes into account different figures of merit, such as RF gain, spurious-free dynamic range and RF output power stability as a function of temperature. The thermal characterization from -10 to +70 °C demonstrates a 27 dB flat photonics-assisted RF gain over the entire frequency range under real operational conditions of a base station for illustrating the feasibility of the photonics-assisted RF amplifier for 5G networks.

  11. X-γ dose rate continuous monitor with wide range based on single-chip microcomputer

    International Nuclear Information System (INIS)

    Wu Debo; Ling Qiu; Guo Lanying; Yang Binhua

    2007-01-01

    This paper describes a concept about circuit designing of X-γ dose rate continuous monitor with wide range based on single-chip microcomputer, and also presents the design procedure of hardware and software, and gives several methods for solving the design procedure of hardware and software with emphasis. (authors)

  12. Laparoscopic Cholecystectomy under Segmental Thoracic Spinal Anesthesia: A Feasible Economical Alternative.

    Science.gov (United States)

    Kejriwal, Aditya Kumar; Begum, Shaheen; Krishan, Gopal; Agrawal, Richa

    2017-01-01

    Laparoscopic surgery is normally performed under general anesthesia, but regional techniques like thoracic epidural and lumbar spinal have been emerging and found beneficial. We performed a clinical case study of segmental thoracic spinal anaesthesia in a healthy patient. We selected an ASA grade I patient undergoing elective laparoscopic cholecystectomy and gave spinal anesthetic in T10-11 interspace using 1 ml of bupivacaine 5 mg ml -1 mixed with 0.5 ml of fentanyl 50 μg ml -1 . Other drugs were only given (systemically) to manage patient anxiety, pain, nausea, hypotension, or pruritus during or after surgery. The patient was reviewed 2 days postoperatively in ward. The thoracic spinal anesthetia was performed easily in the patient. Some discomfort which was readily treated with 1mg midazolam and 20 mg ketamine intravenously. There was no neurological deficit and hemodynamic parameters were in normal range intra and post-operatively and recovery was uneventful. We used a narrow gauze (26G) spinal needle which minimized the trauma to the patient and the chances of PDPH, which was more if 16 or 18G epidural needle had been used and could have increased further if there have been accidental dura puncture. Also using spinal anesthesia was economical although it should be done cautiously as we are giving spinal anesthesia above the level of termination of spinal cord.

  13. Dynamic range broadening for photomultipliers in kinetic spectrophotometry

    International Nuclear Information System (INIS)

    Rumas, V.K.

    1983-01-01

    The circuit of switching on a photomultiplier with prestage modulation developed for kinetic spectrophotometry purposes is described. Distinguishing features of the scheme are wide range of control pulse duration (40 nc - 2.5 mc) and direct transistor photostart by laser light pulse. In the case of PM prestage modulation for the second dynode modulation depth attains 400 while PM opening time constitutes 40 nc

  14. Modelling seasonal habitat suitability for wide-ranging species: Invasive wild pigs in northern Australia.

    Directory of Open Access Journals (Sweden)

    Jens G Froese

    Full Text Available Invasive wildlife often causes serious damage to the economy and agriculture as well as environmental, human and animal health. Habitat models can fill knowledge gaps about species distributions and assist planning to mitigate impacts. Yet, model accuracy and utility may be compromised by small study areas and limited integration of species ecology or temporal variability. Here we modelled seasonal habitat suitability for wild pigs, a widespread and harmful invader, in northern Australia. We developed a resource-based, spatially-explicit and regional-scale approach using Bayesian networks and spatial pattern suitability analysis. We integrated important ecological factors such as variability in environmental conditions, breeding requirements and home range movements. The habitat model was parameterized during a structured, iterative expert elicitation process and applied to a wet season and a dry season scenario. Model performance and uncertainty was evaluated against independent distributional data sets. Validation results showed that an expert-averaged model accurately predicted empirical wild pig presences in northern Australia for both seasonal scenarios. Model uncertainty was largely associated with different expert assumptions about wild pigs' resource-seeking home range movements. Habitat suitability varied considerably between seasons, retracting to resource-abundant rainforest, wetland and agricultural refuge areas during the dry season and expanding widely into surrounding grassland floodplains, savanna woodlands and coastal shrubs during the wet season. Overall, our model suggested that suitable wild pig habitat is less widely available in northern Australia than previously thought. Mapped results may be used to quantify impacts, assess risks, justify management investments and target control activities. Our methods are applicable to other wide-ranging species, especially in data-poor situations.

  15. MR determination of neonatal spinal canal depth.

    Science.gov (United States)

    Arthurs, Owen; Thayyil, Sudhin; Wade, Angie; Chong, W K Kling; Sebire, Neil J; Taylor, Andrew M

    2012-08-01

    Lumbar punctures (LPs) are frequently performed in neonates and often result in traumatic haemorrhagic taps. Knowledge of the distance from the skin to the middle of the spinal canal (mid-spinal canal depth - MSCD) may reduce the incidence of traumatic taps, but there is little data in extremely premature or low birth weight neonates. Here, we determined the spinal canal depth at post-mortem in perinatal deaths using magnetic resonance imaging (MRI). Spinal canal depth was measured in 78 post-mortem foetuses and perinatal cases (mean gestation 26 weeks; mean weight 1.04kg) at the L3/L4 inter-vertebral space at post-mortem MRI. Both anterior (ASCD) and posterior (PSCD) spinal canal depth were measured; MSCD was calculated and modelled against weight and gestational age. ASCD and PSCD (mm) correlated significantly with weight and gestational age (all r>0.8). A simple linear model MSCD (mm)=3×Weight (kg)+5 was the best fit, identifying an SCD value within the correct range for 87.2% (68/78) (95% CI (78.0, 92.9%)) cases. Gestational age did not add significantly to the predictive value of the model. There is a significant correlation between MSCD and body weight at post-mortem MRI in foetuses and perinatal deaths. If this association holds in preterm neonates, use of the formula MSCD (mm)=3×Weight (kg)+5 could result in fewer traumatic LPs in this population. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. MR determination of neonatal spinal canal depth

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen, E-mail: owenarthurs@uk2.net [Centre for Cardiovascular MR, Great Ormond Street Hospital for Children, London WC1N 3JH (United Kingdom); Thayyil, Sudhin, E-mail: s.thayyil@ucl.ac.uk [Academic Neonatology, Institute for Women' s Health, London WC1E 6AU (United Kingdom); Wade, Angie, E-mail: a.wade@ucl.ac.uk [Centre for Paediatric Epidemiology and Biostatistics, UCL Institute of Child Health, London (United Kingdom); Chong, W.K., E-mail: Kling.Chong@gosh.nhs.uk [Paediatric Neuroradiology, Great Ormond Street Hospital for Children, London (United Kingdom); Sebire, Neil J., E-mail: Neil.Sebire@gosh.nhs.uk [Histopathology, Great Ormond Street Hospital for Children, London WC1E 6AU (United Kingdom); Taylor, Andrew M., E-mail: a.taylor76@ucl.ac.uk [Centre for Cardiovascular MR, Cardiorespiratory Unit, Great Ormond Street Hospital for Children and UCL Institute of Cardiovascular Science, London WC1E 6AU (United Kingdom)

    2012-08-15

    Objectives: Lumbar punctures (LPs) are frequently performed in neonates and often result in traumatic haemorrhagic taps. Knowledge of the distance from the skin to the middle of the spinal canal (mid-spinal canal depth - MSCD) may reduce the incidence of traumatic taps, but there is little data in extremely premature or low birth weight neonates. Here, we determined the spinal canal depth at post-mortem in perinatal deaths using magnetic resonance imaging (MRI). Patients and methods: Spinal canal depth was measured in 78 post-mortem foetuses and perinatal cases (mean gestation 26 weeks; mean weight 1.04 kg) at the L3/L4 inter-vertebral space at post-mortem MRI. Both anterior (ASCD) and posterior (PSCD) spinal canal depth were measured; MSCD was calculated and modelled against weight and gestational age. Results: ASCD and PSCD (mm) correlated significantly with weight and gestational age (all r > 0.8). A simple linear model MSCD (mm) = 3 Multiplication-Sign Weight (kg) + 5 was the best fit, identifying an SCD value within the correct range for 87.2% (68/78) (95% CI (78.0, 92.9%)) cases. Gestational age did not add significantly to the predictive value of the model. Conclusion: There is a significant correlation between MSCD and body weight at post-mortem MRI in foetuses and perinatal deaths. If this association holds in preterm neonates, use of the formula MSCD (mm) = 3 Multiplication-Sign Weight (kg) + 5 could result in fewer traumatic LPs in this population.

  17. Thoracolumbar spine model with articulated ribcage for the prediction of dynamic spinal loading.

    Science.gov (United States)

    Ignasiak, Dominika; Dendorfer, Sebastian; Ferguson, Stephen J

    2016-04-11

    Musculoskeletal modeling offers an invaluable insight into the spine biomechanics. A better understanding of thoracic spine kinetics is essential for understanding disease processes and developing new prevention and treatment methods. Current models of the thoracic region are not designed for segmental load estimation, or do not include the complex construct of the ribcage, despite its potentially important role in load transmission. In this paper, we describe a numerical musculoskeletal model of the thoracolumbar spine with articulated ribcage, modeled as a system of individual vertebral segments, elastic elements and thoracic muscles, based on a previously established lumbar spine model and data from the literature. The inverse dynamics simulations of the model allow the prediction of spinal loading as well as costal joints kinetics and kinematics. The intradiscal pressure predicted by the model correlated well (R(2)=0.89) with reported intradiscal pressure measurements, providing a first validation of the model. The inclusion of the ribcage did not affect segmental force predictions when the thoracic spine did not perform motion. During thoracic motion tasks, the ribcage had an important influence on the predicted compressive forces and muscle activation patterns. The compressive forces were reduced by up to 32%, or distributed more evenly between thoracic vertebrae, when compared to the predictions of the model without ribcage, for mild thoracic flexion and hyperextension tasks, respectively. The presented musculoskeletal model provides a tool for investigating thoracic spine loading and load sharing between vertebral column and ribcage during dynamic activities. Further validation for specific applications is still necessary. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. The use of new facility by means internal balance with sting support for wide range Angle of Attack aircraft

    Science.gov (United States)

    Subagyo; Daryanto, Yanto; Risnawan, Novan

    2018-04-01

    The development of facilities for the testing of wide range angle of attack aircraft in the wind tunnel at subsonic regime has done and implemented. Development required to meet the test at an angle of attack from -20 ° to 40 °. Testing the wide range angle of attack aircraft with a wide variation of the angle of attack become important needs. This can be done simply by using the sting support-equipped by internal balance to measure the forces and moments component aerodynamics. The results of development and use on the wide range angle of attack aircraft testing are aerodynamics characteristics in the form of the coefficient three components forces and the three components of the moment. A series of test aircraft was successfully carried out and the results are shown in the form of graphs of characteristic of aerodynamics at wind speed 70 m/s.

  19. Vertebral hemangioma: an important differential in the evaluation of locally aggressive spinal lesions.

    Science.gov (United States)

    Alexander, Justin; Meir, Adam; Vrodos, Nikitas; Yau, Yun-Hom

    2010-08-15

    A case report and a discussion of recent published data. To highlight the importance of vertebral hemangioma (VH) as a differential diagnosis in the evaluation of locally aggressive spinal lesions. VH commonly occur as incidental findings, however, locally aggressive VH have been described. Difficulties in diagnosing these lesions are well reported and relate to changes in fat content causing uncharacteristic appearances on imaging. The management options for these lesions include a combination of observation, embolization, sclerotherapy, surgical decompression, or stabilization and radiotherapy. A 45-year-old patient who was previously well presented with back pain and rapidly progressive paraparesis. Imaging confirmed the presence of an extensive lesion centered within the right T3 vertebral pedicle with intrusion into the spinal canal. Urgent surgical decompression was undertaken and was complicated by extensive intraoperative hemorrhage requiring massive transfusion. Histologically, the lesion was shown to be a cavernous VH with no evidence of malignancy. Following radiation oncology review, he was offered adjuvant radiotherapy to minimize the risks of recurrence. He achieved a near full neurologic recovery within 2 weeks and had a full recovery by 12 months. VH should be considered in the evaluation of locally aggressive spinal lesions. Angiography is a useful adjunct in the evaluation of these lesions, both as a diagnostic and therapeutic tool. After diagnosed correctly a wide range of treatment options exist that may prevent the patient from undergoing major surgical resection and reconstruction procedures, which may be associated with high rates of morbidity.

  20. Large-scale synchronized activity in the embryonic brainstem and spinal cord

    Directory of Open Access Journals (Sweden)

    Yoko eMomose-Sato

    2013-04-01

    Full Text Available In the developing central nervous system, spontaneous activity appears well before the brain responds to external sensory inputs. One of the earliest activities is observed in the hindbrain and spinal cord, which is detected as rhythmic electrical discharges of cranial and spinal motoneurons or oscillations of Ca2+- and voltage-related optical signals. Shortly after the initial expression, the spontaneous activity appearing in the hindbrain and spinal cord exhibits a large-scale correlated wave that propagates over a wide region of the central nervous system, maximally extending to the lumbosacral cord and to the forebrain. In this review, we describe several aspects of this synchronized activity by focusing on the basic properties, development, origin, propagation pattern, pharmacological characteristics, and possible mechanisms underlying the generation of the activity. These profiles differ from those of the respiratory and locomotion pattern generators observed in the mature brainstem and spinal cord, suggesting that the wave is primordial activity that appears during a specific period of embryonic development and plays some important roles in the development of the central nervous system.

  1. Thermotaxis of human sperm cells in extraordinarily shallow temperature gradients over a wide range.

    Directory of Open Access Journals (Sweden)

    Anat Bahat

    Full Text Available On the basis of the finding that capacitated (ready to fertilize rabbit and human spermatozoa swim towards warmer temperatures by directing their movement along a temperature gradient, sperm thermotaxis has been proposed to be one of the processes guiding these spermatozoa to the fertilization site. Although the molecular mechanism underlying sperm thermotaxis is gradually being revealed, basic questions related to this process are still open. Here, employing human spermatozoa, we addressed the questions of how wide the temperature range of thermotaxis is, whether this range includes an optimal temperature or whether spermatozoa generally prefer swimming towards warmer temperatures, whether or not they can sense and respond to descending temperature gradients, and what the minimal temperature gradient is to which they can thermotactically respond. We found that human spermatozoa can respond thermotactically within a wide temperature range (at least 29-41°C, that within this range they preferentially accumulate in warmer temperatures rather than at a single specific, preferred temperature, that they can respond to both ascending and descending temperature gradients, and that they can sense and thermotactically respond to temperature gradients as low as <0.014°C/mm. This temperature gradient is astonishingly low because it means that as a spermatozoon swims through its entire body length (46 µm it can sense and respond to a temperature difference of <0.0006°C. The significance of this surprisingly high temperature sensitivity is discussed.

  2. Comprehensive Measurement of Atmospheric Aerosols with a Wide Range Aerosol Spectrometer

    International Nuclear Information System (INIS)

    Keck, L; Pesch, M; Grimm, H

    2011-01-01

    A wide range aerosol spectrometer (WRAS) was used for comprehensive long term measurements of aerosol size distributions. The system combines the results of an optical aerosol spectrometer with the results of a Scanning Mobility Particle Sizer (SMPS) to record essentially the full size range (5 nm - 32 μm) of atmospheric particles in 72 channels. Measurements were carried out over one year (2009) at the Global Atmospheric Watch (GAW)-Station Hohenpeissenberg, Bavaria. Total particle number concentrations obtained from the aerosol size distributions were compared to the total number concentrations measured by a Condensation Particle Counter (CPC). The comparison showed an excellent agreement of the data. The high time resolution of 5 minutes allows the combination of the measured size distributions with meteorological data and correlations to gaseous pollutants (CO, NOx and SO2). A good correlation of particle number and CO concentrations was found for long distance transported small particles, which were probably mainly soot particles. Correlations to NOx were observed for aerosols from local sources such as traffic emissions. The formation of secondary aerosols from gaseous precursors was also observed. Episodes of relatively high concentration of particles in the range of 2-3 μm were probably caused by pollen.

  3. A Low-Power High-Dynamic-Range Receiver System for In-Probe 3-D Ultrasonic Imaging.

    Science.gov (United States)

    Attarzadeh, Hourieh; Xu, Ye; Ytterdal, Trond

    2017-10-01

    In this paper, a dual-mode low-power, high dynamic-range receiver circuit is designed for the interface with a capacitive micromachined ultrasonic transducer. The proposed ultrasound receiver chip enables the development of an in-probe digital beamforming imaging system. The flexibility of having two operation modes offers a high dynamic range with minimum power sacrifice. A prototype of the chip containing one receive channel, with one variable transimpedance amplifier (TIA) and one analog to digital converter (ADC) circuit is implemented. Combining variable gain TIA functionality with ADC gain settings achieves an enhanced overall high dynamic range, while low power dissipation is maintained. The chip is designed and fabricated in a 65 nm standard CMOS process technology. The test chip occupies an area of 76[Formula: see text] 170 [Formula: see text]. A total average power range of 60-240 [Formula: see text] for a sampling frequency of 30 MHz, and a center frequency of 5 MHz is measured. An instantaneous dynamic range of 50.5 dB with an overall dynamic range of 72 dB is obtained from the receiver circuit.

  4. Changes in lumbosacral spinal nerve roots on diffusion tensor imaging in spinal stenosis

    Directory of Open Access Journals (Sweden)

    Zhong-jun Hou

    2015-01-01

    Full Text Available Lumbosacral degenerative disc disease is a common cause of lower back and leg pain. Conventional T1-weighted imaging (T1WI and T2-weighted imaging (T2WI scans are commonly used to image spinal cord degeneration. However, these modalities are unable to image the entire lumbosacral spinal nerve roots. Thus, in the present study, we assessed the potential of diffusion tensor imaging (DTI for quantitative assessment of compressed lumbosacral spinal nerve roots. Subjects were 20 young healthy volunteers and 31 patients with lumbosacral stenosis. T2WI showed that the residual dural sac area was less than two-thirds that of the corresponding normal area in patients from L 3 to S 1 stenosis. On T1WI and T2WI, 74 lumbosacral spinal nerve roots from 31 patients showed compression changes. DTI showed thinning and distortion in 36 lumbosacral spinal nerve roots (49% and abruption in 17 lumbosacral spinal nerve roots (23%. Moreover, fractional anisotropy values were reduced in the lumbosacral spinal nerve roots of patients with lumbosacral stenosis. These findings suggest that DTI can objectively and quantitatively evaluate the severity of lumbosacral spinal nerve root compression.

  5. Changes in lumbosacral spinal nerve roots on diffusion tensor imaging in spinal stenosis.

    Science.gov (United States)

    Hou, Zhong-Jun; Huang, Yong; Fan, Zi-Wen; Li, Xin-Chun; Cao, Bing-Yi

    2015-11-01

    Lumbosacral degenerative disc disease is a common cause of lower back and leg pain. Conventional T1-weighted imaging (T1WI) and T2-weighted imaging (T2WI) scans are commonly used to image spinal cord degeneration. However, these modalities are unable to image the entire lumbosacral spinal nerve roots. Thus, in the present study, we assessed the potential of diffusion tensor imaging (DTI) for quantitative assessment of compressed lumbosacral spinal nerve roots. Subjects were 20 young healthy volunteers and 31 patients with lumbosacral stenosis. T2WI showed that the residual dural sac area was less than two-thirds that of the corresponding normal area in patients from L3 to S1 stenosis. On T1WI and T2WI, 74 lumbosacral spinal nerve roots from 31 patients showed compression changes. DTI showed thinning and distortion in 36 lumbosacral spinal nerve roots (49%) and abruption in 17 lumbosacral spinal nerve roots (23%). Moreover, fractional anisotropy values were reduced in the lumbosacral spinal nerve roots of patients with lumbosacral stenosis. These findings suggest that DTI can objectively and quantitatively evaluate the severity of lumbosacral spinal nerve root compression.

  6. Skipping Posterior Dynamic Transpedicular Stabilization for Distant Segment Degenerative Disease

    Directory of Open Access Journals (Sweden)

    Bilgehan Solmaz

    2012-01-01

    Full Text Available Objective. To date, there is still no consensus on the treatment of spinal degenerative disease. Current surgical techniques to manage painful spinal disorders are imperfect. In this paper, we aimed to evaluate the prospective results of posterior transpedicular dynamic stabilization, a novel surgical approach that skips the segments that do not produce pain. This technique has been proven biomechanically and radiologically in spinal degenerative diseases. Methods. A prospective study of 18 patients averaging 54.94 years of age with distant spinal segment degenerative disease. Indications consisted of degenerative disc disease (57%, herniated nucleus pulposus (50%, spinal stenosis (14.28%, degenerative spondylolisthesis (14.28%, and foraminal stenosis (7.1%. The Oswestry Low-Back Pain Disability Questionnaire and visual analog scale (VAS for pain were recorded preoperatively and at the third and twelfth postoperative months. Results. Both the Oswestry and VAS scores showed significant improvement postoperatively (P<0.05. We observed complications in one patient who had spinal epidural hematoma. Conclusion. We recommend skipping posterior transpedicular dynamic stabilization for surgical treatment of distant segment spinal degenerative disease.

  7. Dimensions of the lumbar spinal canal: variations and correlations with somatometric parameters using CT

    International Nuclear Information System (INIS)

    Karantanas, A.H.; Zibis, A.H.; Papaliaga, M.; Georgiou, E.; Rousogiannis, S.

    1998-01-01

    The aim of this study was to investigate the correlation of vertebral dimensions with somatometric parameters in patients without clinical symptoms and radiological signs of central lumbar spinal stenosis. One hundred patients presenting with low back pain or sciatica were studied with CT. In each of the L3, L4 and L5 vertebra three slices were taken with the following measurements: 1. Slice through the intervertebral disc: (a) spinal canal area; (b) interarticular diameter; (c) interligamentous diameter. 2. Slice below the vertebral arcus: (a) dural sac area; (b) vertebral body area. 3. Pediculolaminar level: (a) anteroposterior diameter and interpedicular diameter of the spinal canal; (b) spinal canal area; (c) width of the lateral recesses. The Jones-Thomson index was also estimated. The results of the present study showed that there is a statistically significant correlation of height, weight and age with various vertebral indices. The conventional, widely accepted, anteroposterior diameter of 11.5 mm of the lumbar spinal canal is independent of somatometric parameters, and it is the only constant measurement for the estimation of lumbar spinal stenosis with a single value. The present study suggests that there are variations of the dimensions of the lumbar spinal canal and correlations with height, weight and age of the patient. (orig.)

  8. Electrolytes for Use in High Energy Lithium-ion Batteries with Wide Operating Temperature Range

    Science.gov (United States)

    Smart, Marshall C.; Ratnakumar, B. V.; West, W. C.; Whitcanack, L. D.; Huang, C.; Soler, J.; Krause, F. C.

    2012-01-01

    Met programmatic milestones for program. Demonstrated improved performance with wide operating temperature electrolytes containing ester co-solvents (i.e., methyl butyrate) containing electrolyte additives in A123 prototype cells: Previously demonstrated excellent low temperature performance, including 11C rates at -30 C and the ability to perform well down to -60 C. Excellent cycle life at room temperature has been displayed, with over 5,000 cycles being demonstrated. Good high temperature cycle life performance has also been achieved. Demonstrated improved performance with methyl propionate-containing electrolytes in large capacity prototype cells: Demonstrated the wide operating temperature range capability in large cells (12 Ah), successfully scaling up technology from 0.25 Ah size cells. Demonstrated improved performance at low temperature and good cycle life at 40 C with methyl propionate-based electrolyte containing increasing FEC content and the use of LiBOB as an additive. Utilized three-electrode cells to investigate the electrochemical characteristics of high voltage systems coupled with wide operating temperature range electrolytes: From Tafel polarization measurements on each electrode, it is evident the NMC-based cathode displays poor lithium kinetics (being the limiting electrode). The MB-based formulations containing LiBOB delivered the best rate capability at low temperature, which is attributed to improved cathode kinetics. Whereas, the use of lithium oxalate as an additive lead to the highest reversible capacity and lower irreversible losses.

  9. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Cord Injury Diane M. Rowles, MS, NP How Family Life Changes After Spinal Cord Injury Nancy Rosenberg, ... Children with Spinal Cord Injury Patricia Mucia, RN Family Life After Pediatric Spinal Injury Dawn Sheaffer, MSW ...

  10. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... spinal cord injury? play_arrow What kind of surgery is common after a spinal cord injury? play_ ... How soon after a spinal cord injury should surgery be performed? play_arrow Is it common to ...

  11. Spinal sensory projection neuron responses to spinal cord stimulation are mediated by circuits beyond gate control.

    Science.gov (United States)

    Zhang, Tianhe C; Janik, John J; Peters, Ryan V; Chen, Gang; Ji, Ru-Rong; Grill, Warren M

    2015-07-01

    Spinal cord stimulation (SCS) is a therapy used to treat intractable pain with a putative mechanism of action based on the Gate Control Theory. We hypothesized that sensory projection neuron responses to SCS would follow a single stereotyped response curve as a function of SCS frequency, as predicted by the Gate Control circuit. We recorded the responses of antidromically identified sensory projection neurons in the lumbar spinal cord during 1- to 150-Hz SCS in both healthy rats and neuropathic rats following chronic constriction injury (CCI). The relationship between SCS frequency and projection neuron activity predicted by the Gate Control circuit accounted for a subset of neuronal responses to SCS but could not account for the full range of observed responses. Heterogeneous responses were classifiable into three additional groups and were reproduced using computational models of spinal microcircuits representing other interactions between nociceptive and nonnociceptive sensory inputs. Intrathecal administration of bicuculline, a GABAA receptor antagonist, increased spontaneous and evoked activity in projection neurons, enhanced excitatory responses to SCS, and reduced inhibitory responses to SCS, suggesting that GABAA neurotransmission plays a broad role in regulating projection neuron activity. These in vivo and computational results challenge the Gate Control Theory as the only mechanism underlying SCS and refine our understanding of the effects of SCS on spinal sensory neurons within the framework of contemporary understanding of dorsal horn circuitry. Copyright © 2015 the American Physiological Society.

  12. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Counseling Blog About Media Donate Spinal Cord Injury Medical Expert Videos Topics menu Topics Spinal Cord Injury ... Jennifer Piatt, PhD David Chen, MD Read Bio Medical Director, Spinal Cord Injury Rehabilitation Program, Rehabilitation Institute ...

  13. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... L Sarah Harrison, OT Anne Bryden, OT The Role of the Social Worker after Spinal Cord Injury ... a spinal cord injury important? play_arrow What role does “compression” play in a spinal cord injury? ...

  14. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Blog About Media Donate Spinal Cord Injury Medical Expert Videos Topics menu Topics Spinal Cord Injury 101 ... arrow What is the “Spinal Cord Injury Model Systems” program? play_arrow What are the most promising ...

  15. The French 35-hour workweek: a wide-ranging social change.

    Science.gov (United States)

    Prunier-Poulmaire, S; Gadbois, C

    2001-12-01

    The reduction of the legal working week to 35 hours in France has generated wide-ranging social change. We examine the resulting changes in working-time patterns as well as their repercussions on the use of the time gained and on the quality of life and health. To compensate the reduction in the length of the working week, companies have modified the working-time patterns, by extending operation time (shiftwork, atypical schedules) and by matching the on-site workforce to production requirements (flexible working hours). They have sought to make more efficient use of working time: job intensification or job compression. The effects on the off-the-job life and health are linked to the shiftwork and atypical schedules designed to increase the company's operating time, and adjustments to the company's need for flexibilization impose working time/free time patterns that are at odds with biological rhythms and social life patterns. Changes to working-time patterns have unexpected consequences for work organization: heightened difficulties for the individual and the crew. These changes may generate a range of health problems related to overwork and stress. The way some companies have adapted may call into question the usefulness of work done by employees, thus damaging their social identity and mental well-being.

  16. Radiation therapy for primary spinal cord tumors in adults

    International Nuclear Information System (INIS)

    Jeremic, B.; Grujicic, D.; Jovanovic, D.; Djuric, L.; Mijatovic, L.

    1990-01-01

    This paper evaluates the role of radiation therapy in management of primary spinal cord tumors in adults. Records of 21 patients with primary spinal cord tumors treated with radiation therapy after surgery were retrospectively reviewed. Histologic examination showed two diffuse and 10 localized ependymomas, six low-grade gliomas, and three malignant gliomas. Surgery consisted of gross tumor resection in six patients, subtotal resection in three patients, and biopsy in 12 patients. Three patients also received chemotherapy. Radiation dose range from 45 to 55 Cy

  17. Trauma: Spinal Cord Injury.

    Science.gov (United States)

    Eckert, Matthew J; Martin, Matthew J

    2017-10-01

    Injuries to the spinal column and spinal cord frequently occur after high-energy mechanisms of injury, or with lower-energy mechanisms, in select patient populations like the elderly. A focused yet complete neurologic examination during the initial evaluation will guide subsequent diagnostic procedures and early supportive measures to help prevent further injury. For patients with injury to bone and/or ligaments, the initial focus should be spinal immobilization and prevention of inducing injury to the spinal cord. Spinal cord injury is associated with numerous life-threatening complications during the acute and long-term phases of care that all acute care surgeons must recognize. Published by Elsevier Inc.

  18. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... Spinal Cord Injury 101 Lawrence Vogel, MD The Basics of Pediatric SCI Rehabilitation Sara Klaas, MSW Transitions for Children with Spinal Cord Injury Patricia Mucia, RN Family Life After Pediatric Spinal Injury Dawn Sheaffer, MSW Rehabilitation ...

  19. Real time analysis of electromagnetic radiation in a very wide frequency range

    Energy Technology Data Exchange (ETDEWEB)

    Peralta, J.A.; Reyes L, P.; Yepez, E. [Escuela Superior de Fisica y Matematicas, Instituto Politecnico Nacional, Edificio 9, U.P. Adolfo Lopez Mateos, Zacatenco, 07738 Mexico D.F. (Mexico)

    2001-07-01

    In this work, we present an electronic apparatus that facilitates the monitoring and analysis of electromagnetic radiation in a very wide frequency range. The device is a combination of real and virtual instruments, taking advantage of new hardware and software; the measurable range of frequencies depends on the speed of an analog/digital converter, reaching tens of Megahertz. The device has been successfully used to monitor the environmental electromagnetic radiation at very low frequency, a very useful parameter in the research of electromagnetic precursors of earthquakes. The apparatus is a new configuration and has advantages with respect to those previously used: when the attached computer is fast, Fourier analysis can be done in real time, can display simultaneously several bands, the digitized data allow a variety of methods of analysis, and the apparatus is very cheap. (Author)

  20. Real time analysis of electromagnetic radiation in a very wide frequency range

    International Nuclear Information System (INIS)

    Peralta, J.A.; Reyes L, P.; Yepez, E.

    2001-01-01

    In this work, we present an electronic apparatus that facilitates the monitoring and analysis of electromagnetic radiation in a very wide frequency range. The device is a combination of real and virtual instruments, taking advantage of new hardware and software; the measurable range of frequencies depends on the speed of an analog/digital converter, reaching tens of Megahertz. The device has been successfully used to monitor the environmental electromagnetic radiation at very low frequency, a very useful parameter in the research of electromagnetic precursors of earthquakes. The apparatus is a new configuration and has advantages with respect to those previously used: when the attached computer is fast, Fourier analysis can be done in real time, can display simultaneously several bands, the digitized data allow a variety of methods of analysis, and the apparatus is very cheap. (Author)

  1. Properties of Wide-dose-range GafChromic Films for Synchrotron Radiation Facility

    International Nuclear Information System (INIS)

    Nariyama, Nobuteru

    2007-01-01

    GafChromic films have been used at SPring-8 to detect the intensively irradiated parts and protect them from damage by being covered with shield or moved. To extend the usable dose range more widely, a new type of sensitive film EBT was investigated for the introduction. Calibration curves were obtained irradiated with 60Co γ rays and compared with those of other GafChromic films. For the application, these films were set in the white x-ray hutch and the dose distribution was measured. Ratio of doses given by EBT and XT-R indicated the degree of the photon spectrum hardness, which depended on the positions. As a result, dose range from 50 mGy to 300 kGy became available for dose distribution measurements, and a set of films having different energy responses was found to give information of photon spectra

  2. Generalized weighted ratio method for accurate turbidity measurement over a wide range.

    Science.gov (United States)

    Liu, Hongbo; Yang, Ping; Song, Hong; Guo, Yilu; Zhan, Shuyue; Huang, Hui; Wang, Hangzhou; Tao, Bangyi; Mu, Quanquan; Xu, Jing; Li, Dejun; Chen, Ying

    2015-12-14

    Turbidity measurement is important for water quality assessment, food safety, medicine, ocean monitoring, etc. In this paper, a method that accurately estimates the turbidity over a wide range is proposed, where the turbidity of the sample is represented as a weighted ratio of the scattered light intensities at a series of angles. An improvement in the accuracy is achieved by expanding the structure of the ratio function, thus adding more flexibility to the turbidity-intensity fitting. Experiments have been carried out with an 850 nm laser and a power meter fixed on a turntable to measure the light intensity at different angles. The results show that the relative estimation error of the proposed method is 0.58% on average for a four-angle intensity combination for all test samples with a turbidity ranging from 160 NTU to 4000 NTU.

  3. Characterizing the location of spinal and vertebral levels in the human cervical spinal cord.

    Science.gov (United States)

    Cadotte, D W; Cadotte, A; Cohen-Adad, J; Fleet, D; Livne, M; Wilson, J R; Mikulis, D; Nugaeva, N; Fehlings, M G

    2015-04-01

    Advanced MR imaging techniques are critical to understanding the pathophysiology of conditions involving the spinal cord. We provide a novel, quantitative solution to map vertebral and spinal cord levels accounting for anatomic variability within the human spinal cord. For the first time, we report a population distribution of the segmental anatomy of the cervical spinal cord that has direct implications for the interpretation of advanced imaging studies most often conducted across groups of subjects. Twenty healthy volunteers underwent a T2-weighted, 3T MRI of the cervical spinal cord. Two experts marked the C3-C8 cervical nerve rootlets, C3-C7 vertebral bodies, and pontomedullary junction. A semiautomated algorithm was used to locate the centerline of the spinal cord and measure rostral-caudal distances from a fixed point in the brain stem, the pontomedullary junction, to each of the spinal rootlets and vertebral bodies. Distances to each location were compared across subjects. Six volunteers had 2 additional scans in neck flexion and extension to measure the effects of patient positioning in the scanner. We demonstrated that substantial variation exists in the rostral-caudal position of spinal cord segments among individuals and that prior methods of predicting spinal segments are imprecise. We also show that neck flexion or extension has little effect on the relative location of vertebral-versus-spinal levels. Accounting for spinal level variation is lacking in existing imaging studies. Future studies should account for this variation for accurate interpretation of the neuroanatomic origin of acquired MR signals. © 2015 by American Journal of Neuroradiology.

  4. Disorders of spinal blood circulation

    OpenAIRE

    Hevyak, O.M.; Kuzminskyy, A.P.

    2017-01-01

    Spinal strokes are rare. The most common causes of the haemorrhage are spinal cord trauma, vasculitis with signs of haemorrhagic diathesis, spinal vascular congenital anomalies (malformations) and haemangioma. By localization, haemorrhagic strokes are divided into three groups: haematomyelia, spinal subarachnoid haemorrhage, epidural hematoma. Most cavernous malformations are localized at the cervical level, fewer — at thoracic and lumbar levels of the spinal cord. The clinical case of diagno...

  5. A dynamic range upgrade for neutron backscattering spectroscopy

    International Nuclear Information System (INIS)

    Cook, J.C.; Petry, W.; Heidemann, A.; Barthelemy, J.F.

    1992-01-01

    We report on an instrumental development of the cold neutron backscattering spectrometer IN10 at the Institut Laue-Langevin which has led to a significant increase in its dynamic range. Thermal expansion of a variety of neutron monochromator crystals is used instead of a mechanical oscillation of the monochromator, yielding an increase in the energy transfer range by nearly two orders of magnitude in an elastic wave vector transfer range of 0.07≤Q (A -1 )≤2.0. Using this new configuration, first inelastic measurements have been performed using the (200) reflections from KCl and NaCl monochromators with crystal temperatures between 80 K and 700 K. The thermal expansion of these crystals in this temperature range gives rise to energy transfer ranges (neutron energy gain) of -16<ℎω(μeV)<+83 for KCl and -530<ℎω(μeV)<-420 for NaCl with energy resolution (FWHM) of around 0.6 and 1.4 μeV for KCl and NaCl respectively. These figures represent the highest energy resolution currently available at these energy and wave vector transfers. (orig.)

  6. Modelling of the CSF flow in the spinal canal in cervical stenosis

    Czech Academy of Sciences Publication Activity Database

    Kaczmarská, A.; Štěpáník, Z.; Vaněk, P.; Maršík, František; Převorovská, Světlana; Otáhal, J.

    2007-01-01

    Roč. 40, - (2007), s. 477-477 ISSN 0021-9290 Institutional research plan: CEZ:AV0Z20760514 Keywords : cerebrospinal fluid flow * spinal canal * cervical stenosis Subject RIV: BK - Fluid Dynamics Impact factor: 2.897, year: 2007

  7. Diagnosis and surgical treatment of terminal syringomyelia within spinal cord combined with tethered cord syndrome

    Directory of Open Access Journals (Sweden)

    Jing-cheng XIE

    2016-04-01

    Full Text Available Objective To summarize the clinical manifestations, imaging characteristics and experience of surgical treatment of spinal cord terminal syringomyelia with tethered cord syndrome (TCS.  Methods and Results Clinical data of 10 patients with spinal cord syringomyelia combined with TCS surgically treated under microscope from January 1999 to March 2014 in our hospital were retrospectively analyzed. There were 3 males and 7 females with average age of 15.06 years old (ranged from 2 to 35 years old. The course of disease ranged from 3 months to 20 years (average 42.17 months. Among those patients, one patient presented hydromyelia, 8 patients suffered from meningeal cyst within the sacral canal, and one patient were concurrent with sacral dermal sinus. The weakness of lower extremities, especially distal limbs, was the main clinical manifestation. Five patients were accompanied with bowel and bladder dysfunction and 5 patients with sensory disturbance below the level of syringomyelia, especially hypesthesia. Preoperative MRI showed conus medullaris disappeared at the end of spinal cord, and there was fluid signal in the lower spinal cord with hypo-intensity signal in T1WI and hyper-intensity signal in T2WI without enhancement. All patients underwent surgical procedures. Under microscope, filum terminale was cut off, drainage was performed, meningeal cyst within the sacral canal was removed, and tethered cord was released. The success rate of operations was 100%. The duration of surgery ranged from 1.52 to 3.07 h (average 2.15 h, with average intraoperative blood loss 220 ml (ranged from 100 to 410 ml. The tethering filum had been totally resected and histological examination showed typical filum tissue in all cases. No operative complication was found. Visual Analogue Scale (VAS score was decreased, and the lower limbs weakness as well as bowel and bladder dysfunction was gradually relieved after operation. The period of follow-up was ranged from 6

  8. In Vivo Spinal Posture during Upright and Reclined Sitting in an Office Chair

    Directory of Open Access Journals (Sweden)

    Roland Zemp

    2013-01-01

    Full Text Available Increasing numbers of people spend the majority of their working lives seated in an office chair. Musculoskeletal disorders, in particular low back pain, resulting from prolonged static sitting are ubiquitous, but regularly changing sitting position throughout the day is thought to reduce back problems. Nearly all currently available office chairs offer the possibility to alter the backrest reclination angles, but the influence of changing seating positions on the spinal column remains unknown. In an attempt to better understand the potential to adjust or correct spine posture using adjustable seating, five healthy subjects were analysed in an upright and reclined sitting position conducted in an open, upright MRI scanner. The shape of the spine, as described using the vertebral bodies’ coordinates, wedge angles, and curvature angles, showed high inter-subject variability between the two seating positions. The mean lumbar, thoracic, and cervical curvature angles were 29±15°, -29±4°, and 13±8° for the upright and 33±12°, -31±7°, and 7±7° for the reclined sitting positions. Thus, a wide range of seating adaptation is possible through modification of chair posture, and dynamic seating options may therefore provide a key feature in reducing or even preventing back pain caused by prolonged static sitting.

  9. The minimally invasive spinal deformity surgery algorithm: a reproducible rational framework for decision making in minimally invasive spinal deformity surgery.

    Science.gov (United States)

    Mummaneni, Praveen V; Shaffrey, Christopher I; Lenke, Lawrence G; Park, Paul; Wang, Michael Y; La Marca, Frank; Smith, Justin S; Mundis, Gregory M; Okonkwo, David O; Moal, Bertrand; Fessler, Richard G; Anand, Neel; Uribe, Juan S; Kanter, Adam S; Akbarnia, Behrooz; Fu, Kai-Ming G

    2014-05-01

    Minimally invasive surgery (MIS) is an alternative to open deformity surgery for the treatment of patients with adult spinal deformity. However, at this time MIS techniques are not as versatile as open deformity techniques, and MIS techniques have been reported to result in suboptimal sagittal plane correction or pseudarthrosis when used for severe deformities. The minimally invasive spinal deformity surgery (MISDEF) algorithm was created to provide a framework for rational decision making for surgeons who are considering MIS versus open spine surgery. A team of experienced spinal deformity surgeons developed the MISDEF algorithm that incorporates a patient's preoperative radiographic parameters and leads to one of 3 general plans ranging from MIS direct or indirect decompression to open deformity surgery with osteotomies. The authors surveyed fellowship-trained spine surgeons experienced with spinal deformity surgery to validate the algorithm using a set of 20 cases to establish interobserver reliability. They then resurveyed the same surgeons 2 months later with the same cases presented in a different sequence to establish intraobserver reliability. Responses were collected and tabulated. Fleiss' analysis was performed using MATLAB software. Over a 3-month period, 11 surgeons completed the surveys. Responses for MISDEF algorithm case review demonstrated an interobserver kappa of 0.58 for the first round of surveys and an interobserver kappa of 0.69 for the second round of surveys, consistent with substantial agreement. In at least 10 cases there was perfect agreement between the reviewing surgeons. The mean intraobserver kappa for the 2 surveys was 0.86 ± 0.15 (± SD) and ranged from 0.62 to 1. The use of the MISDEF algorithm provides consistent and straightforward guidance for surgeons who are considering either an MIS or an open approach for the treatment of patients with adult spinal deformity. The MISDEF algorithm was found to have substantial inter- and

  10. Quantum conductance of carbon nanotubes in a wide energy range

    International Nuclear Information System (INIS)

    Zhang, Yong

    2015-01-01

    The differential conductance of armchair and zigzag carbon nanotubes (CNTs) in a wide energy range has been numerically calculated by using the tight-binding model and the Green’s function method. The effects of the contact coupling between CNTs and electrodes on conductance have been explored. The ballistic conductance is proportional to the band numbers and has a ladder-like feature. As the increase of the contact coupling, the conductance oscillations appear and they are robust against the coupling. More importantly, on the first step of the conductance ladder, the armchair CNTs have two quasi-periodic conductance oscillations, i.e. a rapid conductance oscillation superimposed on a slow fluctuation background; while the zigzag CNTs have only one conductance oscillation. But on the second conductance step, all CNTs have two quasi-periodic conductance oscillations. The physical origin of the conductance oscillations has been revealed

  11. Transmission dynamic range in chest radiology

    International Nuclear Information System (INIS)

    Lemmers, H.E.A.S.J.; Schultze Kool, L.J.; van Elburg, H.J.; Boelens, F.

    1989-01-01

    Due to the large difference in transmission between the lung area and the mediastinum, the human chest is a challenging object for radiographic imaging. This study is performed in order to define the dynamic range needed for a chest imaging chain. Eight hundred seventy-five consecutive outpatients were imaged with a prototype AMBER (advanced multiple beam equalization radiography) unit at 141 kVp. The equalization facility was disabled, allowing for the simultaneous capture of a film image and a digital dataset representing the local patient transmission in fields of approximately 2x2 cm. The datasets were analyzed to obtain the relation between the average transmission distribution in a subset of the population and physical parameters characterizing this subset, such as body weight or length

  12. Comparison of linear intrascan and interscan dynamic ranges of Orbitrap and ion-mobility time-of-flight mass spectrometers.

    Science.gov (United States)

    Kaufmann, Anton; Walker, Stephan

    2017-11-30

    The linear intrascan and interscan dynamic ranges of mass spectrometers are important in metabolome and residue analysis. A large linear dynamic range is mandatory if both low- and high-abundance ions have to be detected and quantitated in heavy matrix samples. These performance criteria, as provided by modern high-resolution mass spectrometry (HRMS), were systematically investigated. The comparison included two generations of Orbitraps, and an ion mobility quadrupole time-of-flight (QTOF) system In addition, different scan modes, as provided by the utilized instruments, were investigated. Calibration curves of different compounds covering a concentration range of five orders of magnitude were measured to evaluate the linear interscan dynamic range. The linear intrascan dynamic range and the resulting mass accuracy were evaluated by repeating these measurements in the presence of a very intense background. Modern HRMS instruments can show linear dynamic ranges of five orders of magnitude. Often, however, the linear dynamic range is limited by the detection capability (sensitivity and selectivity) and by the electrospray ionization. Orbitraps, as opposed to TOF instruments, show a reduced intrascan dynamic range. This is due to the limited C-trap and Orbitrap capacity. The tested TOF instrument shows poorer mass accuracies than the Orbitraps. In contrast, hyphenation with an ion-mobility device seems not to affect the linear dynamic range. The linear dynamic range of modern HRMS instrumentation has been significantly improved. This also refers to the virtual absence of systematic mass shifts at high ion abundances. The intrascan dynamic range of the current Orbitrap technology may still be a limitation when analyzing complex matrix extracts. On the other hand, the linear dynamic range is not only limited by the detector technology, but can also be shortened by peripheral devices, where the ionization and transfer of ions take place. Copyright © 2017 John Wiley

  13. Development of dose monitoring system applicable to various radiations with wide energy ranges

    International Nuclear Information System (INIS)

    Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira; Yamaguchi, Yasuhiro

    2005-01-01

    A new inventive radiation dose monitor, designated as DARWIN (Dose monitoring system Applicable to various Radiations with WIde energy raNges), has been developed for monitoring doses in workspaces and surrounding environments of high energy accelerator facilities. DARWIN is composed of a phoswitch-type scintillation detector, which consists of liquid organic scintillator BC501A coupled with ZnS(Ag) scintillation sheets doped with 6 Li, and a data acquisition system based on a Digital-Storage-Oscilloscope. Scintillations from the detector induced by thermal and fast neutrons, photons and muons were discriminated by analyzing their waveforms, and their light outputs were directly converted into the corresponding doses by applying the G-function method. Characteristics of DARWIN were studied by both calculation and experiment. The calculated results indicate that DARWIN gives reasonable estimations of doses in most radiation fields. It was found from the experiment that DARWIN has an excellent property of measuring doses from all particles that significantly contribute to the doses in surrounding environments of accelerator facilities - neutron, photon and muon with wide energy ranges. The experimental results also suggested that DARWIN enables us to monitor small fluctuation of neutron dose rates near the background-level owing to its high sensitivity. (author)

  14. Fractional quantum mechanics on networks: Long-range dynamics and quantum transport.

    Science.gov (United States)

    Riascos, A P; Mateos, José L

    2015-11-01

    In this paper we study the quantum transport on networks with a temporal evolution governed by the fractional Schrödinger equation. We generalize the dynamics based on continuous-time quantum walks, with transitions to nearest neighbors on the network, to the fractional case that allows long-range displacements. By using the fractional Laplacian matrix of a network, we establish a formalism that combines a long-range dynamics with the quantum superposition of states; this general approach applies to any type of connected undirected networks, including regular, random, and complex networks, and can be implemented from the spectral properties of the Laplacian matrix. We study the fractional dynamics and its capacity to explore the network by means of the transition probability, the average probability of return, and global quantities that characterize the efficiency of this quantum process. As a particular case, we explore analytically these quantities for circulant networks such as rings, interacting cycles, and complete graphs.

  15. Bipedal locomotion of bonnet macaques after spinal cord injury.

    Science.gov (United States)

    Babu, Rangasamy Suresh; Anand, P; Jeraud, Mathew; Periasamy, P; Namasivayam, A

    2007-10-01

    Experimental studies concerning the analysis of locomotor behavior in spinal cord injury research are widely performed in rodent models. The purpose of this study was to quantitatively evaluate the degree of functional recovery in reflex components and bipedal locomotor behavior of bonnet macaques (Macaca radiata) after spinal contusive injury. Six monkeys were tested for various reflex components (grasping, righting, hopping, extension withdrawal) and were trained preoperatively to walk in bipedal fashion on the simple and complex locomotor runways (narrow beam, grid, inclined plane, treadmill) of this investigation. The overall performance of the animals'motor behavior and the functional status of limb movements during bipedal locomotion were graded by the Combined Behavioral Score (CBS) system. Using the simple Allen weight-drop technique, a contusive injury was produced by dropping a 13-g weight from a height of 30 cm to the exposed spinal cord at the T12-L1 vertebral level of the trained monkeys. All the monkeys showed significant impairments in every reflex activity and in walking behavior during the early part of the postoperative period. In subsequent periods, the animals displayed mild alterations in certain reflex responses, such as grasping, extension withdrawal, and placing reflexes, which persisted through a 1-year follow-up. The contused animals traversed locomotor runways--narrow beam, incline plane, and grid runways--with more steps and few errors, as evaluated with the CBS system. Eventually, the behavioral performance of all spinal-contused monkeys recovered to near-preoperative level by the fifth postoperative month. The findings of this study reveal the recovery time course of various reflex components and bipedal locomotor behavior of spinal-contused macaques on runways for a postoperative period of up to 1 year. Our spinal cord research in primates is advantageous in understanding the characteristics of hind limb functions only, which possibly

  16. Radiological evaluation of the cervical spinal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Bae, W. K.; Koh, B. H.; Hahm, C. K.; Kim, J. J. [School of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1983-03-15

    Acute injuries of the cervical spine are the most common causes of severe disability following trauma, yet the diagnosis of these injuries are often delayed and the treatment, inadequate. Traumatic injuries of the cervical spine are diagnosed by radiological examinations. And complete evaluations of bony structures and soft tissue changes on conventional radiograms are very important for determining the therapeutic plans and prognoses of the injuries patients. During the period of 5 years from June 1976 to May 1981, the radiological and clinical evaluation had been made on 38 patients suffered from acute cervical spinal injuries which were confirmed by the radiological examinations. The results were as follows. 1. Age distribution of total 38 patients was broad ranging from 19 years to 72 years. 2. The most common cause of injury was traffic accident, next fall down, other accident respectively. 3. Levels of the cervical spinal injuries were as follows: Upper cervical spine in 15.8%, lower cervical spine in 84.2%, and the most common injuries level was C 5. Most of the lower cervical spinal injuries were located in the vertebral body and spinous process. 4. Anatomical sites of the cervical spinal injuries were as follows; vertebral body in 55.5%, spinous process in 23.7%, neural arch in 15.8%, and locked facet in 18.4%, etc. 5. Most of the patients with severe mental changes were injuries in upper cervical spine rather than lower. And most of the patients with quadriplegia or paraplegia were shown marked disruption of spinal canal.

  17. Radiological evaluation of the cervical spinal trauma

    International Nuclear Information System (INIS)

    Bae, W. K.; Koh, B. H.; Hahm, C. K.; Kim, J. J.

    1983-01-01

    Acute injuries of the cervical spine are the most common causes of severe disability following trauma, yet the diagnosis of these injuries are often delayed and the treatment, inadequate. Traumatic injuries of the cervical spine are diagnosed by radiological examinations. And complete evaluations of bony structures and soft tissue changes on conventional radiograms are very important for determining the therapeutic plans and prognoses of the injuries patients. During the period of 5 years from June 1976 to May 1981, the radiological and clinical evaluation had been made on 38 patients suffered from acute cervical spinal injuries which were confirmed by the radiological examinations. The results were as follows. 1. Age distribution of total 38 patients was broad ranging from 19 years to 72 years. 2. The most common cause of injury was traffic accident, next fall down, other accident respectively. 3. Levels of the cervical spinal injuries were as follows: Upper cervical spine in 15.8%, lower cervical spine in 84.2%, and the most common injuries level was C 5. Most of the lower cervical spinal injuries were located in the vertebral body and spinous process. 4. Anatomical sites of the cervical spinal injuries were as follows; vertebral body in 55.5%, spinous process in 23.7%, neural arch in 15.8%, and locked facet in 18.4%, etc. 5. Most of the patients with severe mental changes were injuries in upper cervical spine rather than lower. And most of the patients with quadriplegia or paraplegia were shown marked disruption of spinal canal

  18. Management of Penetrating Spinal Cord Injuries in a Non Spinal ...

    African Journals Online (AJOL)

    Management of Penetrating Spinal Cord Injuries in a Non Spinal Centre: Experience at Enugu, Nigeria. ... The thoracic spine{9(41%)}was most often involved. ... Five (23%) patients with injury at cervical level died from respiratory failure.

  19. Image-guided linear accelerator-based spinal radiosurgery for hemangioblastoma.

    Science.gov (United States)

    Selch, Michael T; Tenn, Steve; Agazaryan, Nzhde; Lee, Steve P; Gorgulho, Alessandra; De Salles, Antonio A F

    2012-01-01

    To retrospectively review the efficacy and safety of image-guided linear accelerator-based radiosurgery for spinal hemangioblastomas. Between August 2004 and September 2010, nine patients with 20 hemangioblastomas underwent spinal radiosurgery. Five patients had von Hipple-Lindau disease. Four patients had multiple tumors. Ten tumors were located in the thoracic spine, eight in the cervical spine, and two in the lumbar spine. Tumor volume varied from 0.08 to 14.4 cc (median 0.72 cc). Maximum tumor dimension varied from 2.5 to 24 mm (median 10.5 mm). Radiosurgery was performed with a dedicated 6 MV linear accelerator equipped with a micro-multileaf collimator. Median peripheral tumor dose and prescription isodose were 12 Gy and 90%, respectively. Image guidance was performed by optical tracking of infrared reflectors, fusion of oblique radiographs with dynamically reconstructed digital radiographs, and automatic patient positioning. Follow-up varied from 14 to 86 months (median 51 months). Kaplan-Meier estimated 4-year overall and solid tumor local control rates were 90% and 95%, respectively. One tumor progressed 12 months after treatment and a new cyst developed 10 months after treatment in another tumor. There has been no clinical or imaging evidence for spinal cord injury. Results of this limited experience indicate linear accelerator-based radiosurgery is safe and effective for spinal cord hemangioblastomas. Longer follow-up is necessary to confirm the durability of tumor control, but these initial results imply linear accelerator-based radiosurgery may represent a therapeutic alternative to surgery for selected patients with spinal hemangioblastomas.

  20. Spinal stenosis

    Science.gov (United States)

    ... in the spine that was present from birth Narrow spinal canal that the person was born with Herniated or slipped disk, which ... when you sit down or lean forward. Most people with spinal stenosis cannot walk for a long ... During a physical exam, your health care provider will try to ...

  1. Neuroprotective effects of Ganoderma lucidum polysaccharides against traumatic spinal cord injury in rats.

    Science.gov (United States)

    Gokce, Emre Cemal; Kahveci, Ramazan; Atanur, Osman Malik; Gürer, Bora; Aksoy, Nurkan; Gokce, Aysun; Sargon, Mustafa Fevzi; Cemil, Berker; Erdogan, Bulent; Kahveci, Ozan

    2015-11-01

    Ganoderma lucidum (G. lucidum) is a mushroom belonging to the polyporaceae family of Basidiomycota and has widely been used as a traditional medicine for thousands of years. G. lucidum has never been studied in traumatic spinal cord injury. The aim of this study is to investigate whether G. lucidum polysaccharides (GLPS) can protect the spinal cord after experimental spinal cord injury. Rats were randomized into five groups of eight animals each: control, sham, trauma, GLPS, and methylprednisolone. In the control group, no surgical intervention was performed. In the sham group, only a laminectomy was performed. In all the other groups, the spinal cord trauma model was created by the occlusion of the spinal cord with an aneurysm clip. In the spinal cord tissue, caspase-3 activity, tumour necrosis factor-alpha levels, myeloperoxidase activity, malondialdehyde levels, nitric oxide levels, and superoxide dismutase levels were analysed. Histopathological and ultrastructural evaluations were also performed. Neurological evaluation was performed using the Basso, Beattie, and Bresnahan locomotor scale and the inclined-plane test. After traumatic spinal cord injury, increases in caspase-3 activity, tumour necrosis factor-alpha levels, myeloperoxidase activity, malondialdehyde levels, and nitric oxide levels were detected. After the administration of GLPS, decreases were observed in tissue caspase-3 activity, tumour necrosis factor-alpha levels, myeloperoxidase activity, malondialdehyde levels, and nitric oxide levels. Furthermore, GLPS treatment showed improved results in histopathological scores, ultrastructural scores, and functional tests. Biochemical, histopathological, and ultrastructural analyses and functional tests reveal that GLPS exhibits meaningful neuroprotective effects against spinal cord injury. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Descending brain neurons in larval lamprey: Spinal projection patterns and initiation of locomotion

    Science.gov (United States)

    Shaw, Albert C.; Jackson, Adam W.; Holmes, Tamra; Thurman, Suzie; Davis, G.R.; McClellan, Andrew D.

    2010-01-01

    In larval lamprey, partial lesions were made in the rostral spinal cord to determine which spinal tracts are important for descending activation of locomotion and to identify descending brain neurons that project in these tracts. In whole animals and in vitro brain/spinal cord preparations, brain-initiated spinal locomotor activity was present when the lateral or intermediate spinal tracts were spared but usually was abolished when the medial tracts were spared. We previously showed that descending brain neurons are located in eleven cell groups, including reticulospinal (RS) neurons in the mesenecephalic reticular nucleus (MRN) as well as the anterior (ARRN), middle (MRRN), and posterior (PRRN) rhombencephalic reticular nuclei. Other descending brain neurons are located in the diencephalic (Di) as well as the anterolateral (ALV), dorsolateral (DLV), and posterolateral (PLV) vagal groups. In the present study, the Mauthner and auxillary Mauthner cells, most neurons in the Di, ALV, DLV, and PLV cell groups, and some neurons in the ARRN and PRRN had crossed descending axons. The majority of neurons projecting in medial spinal tracts included large identified Müller cells and neurons in the Di, MRN, ALV, and DLV. Axons of individual descending brain neurons usually did not switch spinal tracts, have branches in multiple tracts, or cross the midline within the rostral cord. Most neurons that projected in the lateral/intermediate spinal tracts were in the ARRN, MRRN, and PRRN. Thus, output neurons of the locomotor command system are distributed in several reticular nuclei, whose neurons project in relatively wide areas of the cord. PMID:20510243

  3. Diagnosis of lumbar central spinal stenosis by plain radiography

    International Nuclear Information System (INIS)

    Ilkko, E.

    1989-01-01

    The usefulness of plain radiography in the diagnosis of lumbar central spinal stenosis was studied in 116 patients using computed tomography (CT) as a reference. The most significant signs found in central spinal stenosis were short pedicles, high narrow intervertebral foramina, small interlaminar windows and deep posterior concavity of the vertebral bodies. The sensitivity of plain radiography in the diagnosis of central spinal stenosis as compared to CT was 66%, the specificity was 93% and the accuracy was 86%. The midsagittal and interpedicular diameters were measured from plain radiograms and were compared with corresponding CT diameters. In approximately half of the cases, the sagittal diameters were compatible. The maximum error was 6 mm. On average, the interpedicular distances were measured as too wide. The reliability of CT measurements were established by taking the measurements from the vertebral column of a moose calf, and then comparing these to the real measurements obtained with a calibrated ruler. The maximal differences were 2 mm. (author). 24 refs.; 8 figs.; 3 tabs

  4. Extraordinary tunable dynamic range of electrochemical aptasensor for accurate detection of ochratoxin A in food samples

    Directory of Open Access Journals (Sweden)

    Lin Cheng

    2017-06-01

    Full Text Available We report the design of a sensitive, electrochemical aptasensor for detection of ochratoxin A (OTA with an extraordinary tunable dynamic sensing range. This electrochemical aptasensor is constructed based on the target induced aptamer-folding detection mechanism and the recognition between OTA and its aptamers results in the conformational change of the aptamer probe and thus signal changes for measurement. The dynamic sensing range of the electrochemical aptasensor is successfully tuned by introduction of free assistant aptamer probes in the sensing system. Our electrochemical aptasensor shows an extraordinary dynamic sensing range of 11-order magnitude of OTA concentration from 10−8 to 102 ng/g. Of great significance, the signal response in all OTA concentration ranges is at the same current scale, demonstrating that our sensing protocol in this research could be applied for accurate detections of OTA in a broad range without using any complicated treatment of signal amplification. Finally, OTA spiked red wine and maize samples in different dynamic sensing ranges are determined with the electrochemical aptasensor under optimized sensing conditions. This tuning strategy of dynamic sensing range may offer a promising platform for electrochemical aptasensor optimizations in practical applications.

  5. A Brain–Spinal Interface Alleviating Gait Deficits after Spinal Cord Injury in Primates

    Science.gov (United States)

    Capogrosso, Marco; Milekovic, Tomislav; Borton, David; Wagner, Fabien; Moraud, Eduardo Martin; Mignardot, Jean-Baptiste; Buse, Nicolas; Gandar, Jerome; Barraud, Quentin; Xing, David; Rey, Elodie; Duis, Simone; Jianzhong, Yang; Ko, Wai Kin D.; Li, Qin; Detemple, Peter; Denison, Tim; Micera, Silvestro; Bezard, Erwan; Bloch, Jocelyne; Courtine, Grégoire

    2016-01-01

    Spinal cord injury disrupts the communication between the brain and the spinal circuits that orchestrate movement. To bypass the lesion, brain–computer interfaces1–3 have directly linked cortical activity to electrical stimulation of muscles, which have restored grasping abilities after hand paralysis1,4. Theoretically, this strategy could also restore control over leg muscle activity for walking5. However, replicating the complex sequence of individual muscle activation patterns underlying natural and adaptive locomotor movements poses formidable conceptual and technological challenges6,7. Recently, we showed in rats that epidural electrical stimulation of the lumbar spinal cord can reproduce the natural activation of synergistic muscle groups producing locomotion8–10. Here, we interfaced leg motor cortex activity with epidural electrical stimulation protocols to establish a brain–spinal interface that alleviated gait deficits after a spinal cord injury in nonhuman primates. Rhesus monkeys were implanted with an intracortical microelectrode array into the leg area of motor cortex; and a spinal cord stimulation system composed of a spatially selective epidural implant and a pulse generator with real-time triggering capabilities. We designed and implemented wireless control systems that linked online neural decoding of extension and flexion motor states with stimulation protocols promoting these movements. These systems allowed the monkeys to behave freely without any restrictions or constraining tethered electronics. After validation of the brain–spinal interface in intact monkeys, we performed a unilateral corticospinal tract lesion at the thoracic level. As early as six days post-injury and without prior training of the monkeys, the brain–spinal interface restored weight-bearing locomotion of the paralyzed leg on a treadmill and overground. The implantable components integrated in the brain–spinal interface have all been approved for investigational

  6. Seasonal source-sink dynamics at the edge of a species' range

    Science.gov (United States)

    Kanda, L.L.; Fuller, T.K.; Sievert, P.R.; Kellogg, R.L.

    2009-01-01

    The roles of dispersal and population dynamics in determining species' range boundaries recently have received theoretical attention but little empirical work. Here we provide data on survival, reproduction, and movement for a Virginia opossum (Didelphis virginiana) population at a local distributional edge in central Massachusetts (USA). Most juvenile females that apparently exploited anthropogenic resources survived their first winter, whereas those using adjacent natural resources died of starvation. In spring, adult females recolonized natural areas. A life-table model suggests that a population exploiting anthropogenic resources may grow, acting as source to a geographically interlaced sink of opossums using only natural resources, and also providing emigrants for further range expansion to new human-dominated landscapes. In a geographical model, this source-sink dynamic is consistent with the local distribution identified through road-kill surveys. The Virginia opossum's exploitation of human resources likely ameliorates energetically restrictive winters and may explain both their local distribution and their northward expansion in unsuitable natural climatic regimes. Landscape heterogeneity, such as created by urbanization, may result in source-sink dynamics at highly localized scales. Differential fitness and individual dispersal movements within local populations are key to generating regional distributions, and thus species ranges, that exceed expectations. ?? 2009 by the Ecological Society of America.

  7. Seasonal source-sink dynamics at the edge of a species' range.

    Science.gov (United States)

    Kanda, L Leann; Fuller, Todd K; Sievert, Paul R; Kellogg, Robert L

    2009-06-01

    The roles of dispersal and population dynamics in determining species' range boundaries recently have received theoretical attention but little empirical work. Here we provide data on survival, reproduction, and movement for a Virginia opossum (Didelphis virginiana) population at a local distributional edge in central Massachusetts (USA). Most juvenile females that apparently exploited anthropogenic resources survived their first winter, whereas those using adjacent natural resources died of starvation. In spring, adult females recolonized natural areas. A life-table model suggests that a population exploiting anthropogenic resources may grow, acting as source to a geographically interlaced sink of opossums using only natural resources, and also providing emigrants for further range expansion to new human-dominated landscapes. In a geographical model, this source-sink dynamic is consistent with the local distribution identified through road-kill surveys. The Virginia opossum's exploitation of human resources likely ameliorates energetically restrictive winters and may explain both their local distribution and their northward expansion in unsuitable natural climatic regimes. Landscape heterogeneity, such as created by urbanization, may result in source-sink dynamics at highly localized scales. Differential fitness and individual dispersal movements within local populations are key to generating regional distributions, and thus species ranges, that exceed expectations.

  8. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... arrow What is the “Spinal Cord Injury Model Systems” program? play_arrow What are the most promising new treatments for spinal cord injuries? play_arrow What are the latest developments in the use of electrical stimulation for spinal cord injuries? play_arrow ...

  9. Health conditions in people with spinal cord injury: Contemporary evidence from a population-based community survey in Switzerland.

    Science.gov (United States)

    Brinkhof, Martin W G; Al-Khodairy, Abdul; Eriks-Hoogland, Inge; Fekete, Christine; Hinrichs, Timo; Hund-Georgiadis, Margret; Meier, Sonja; Scheel-Sailer, Anke; Schubert, Martin; Reinhardt, Jan D

    2016-02-01

    Health conditions in people with spinal cord injury are major determinants for disability, reduced well-being, and mortality. However, population-based evidence on the prevalence and treatment of health conditions in people with spinal cord injury is scarce. To investigate health conditions in Swiss residents with spinal cord injury, specifically to analyse their prevalence, severity, co-occurrence, and treatment. Cross-sectional data (n = 1,549) from the community survey of the Swiss Spinal Cord Injury (SwiSCI) cohort study, including Swiss residents with spinal cord injury aged over 16 years, were analysed. Nineteen health conditions and their self-reported treatment were assessed with the spinal cord injury Secondary Conditions Scale and the Self-Administered Comorbidity Questionnaire. Prevalence and severity were compared across demographics and spinal cord injury characteristics. Co-occurrence of health conditions was examined using a binary non-metric dissimilarity measure and multi-dimensional scaling. Treatment rates were also examined. Number of concurrent health conditions was high (median 7; interquartile range 4-9; most frequent: spasticity, chronic pain, sexual dysfunction). Prevalence of health conditions increased with age and was higher in non-traumatic compared with traumatic spinal cord injury. Spinal cord injury specific conditions co-occurred. Relative frequencies of treatment were low (median 44%, interquartile range 25-64%), even for significant or chronic problems. A high prevalence of multimorbidity was found in community-dwelling persons with spinal cord injury. Treatment for some highly prevalent health conditions was infrequent.

  10. Transcutaneous spinal direct current stimulation of the lumbar and sacral spinal cord: a modelling study

    Science.gov (United States)

    Fernandes, Sofia R.; Salvador, Ricardo; Wenger, Cornelia; de Carvalho, Mamede; Miranda, Pedro C.

    2018-06-01

    Objective. Our aim was to perform a computational study of the electric field (E-field) generated by transcutaneous spinal direct current stimulation (tsDCS) applied over the thoracic, lumbar and sacral spinal cord, in order to assess possible neuromodulatory effects on spinal cord circuitry related with lower limb functions. Approach. A realistic volume conductor model of the human body consisting of 14 tissues was obtained from available databases. Rubber pad electrodes with a metallic connector and a conductive gel layer were modelled. The finite element (FE) method was used to calculate the E-field when a current of 2.5 mA was passed between two electrodes. The main characteristics of the E-field distributions in the spinal grey matter (spinal-GM) and spinal white matter (spinal-WM) were compared for seven montages, with the anode placed either over T10, T8 or L2 spinous processes (s.p.), and the cathode placed over right deltoid (rD), umbilicus (U) and right iliac crest (rIC) areas or T8 s.p. Anisotropic conductivity of spinal-WM and of a group of dorsal muscles near the vertebral column was considered. Main results. The average E-field magnitude was predicted to be above 0.15 V m-1 in spinal cord regions located between the electrodes. L2-T8 and T8-rIC montages resulted in the highest E-field magnitudes in lumbar and sacral spinal segments (>0.30 V m-1). E-field longitudinal component is 3 to 6 times higher than the ventral-dorsal and right-left components in both the spinal-GM and WM. Anatomical features such as CSF narrowing due to vertebrae bony edges or disks intrusions in the spinal canal correlate with local maxima positions. Significance. Computational modelling studies can provide detailed information regarding the electric field in the spinal cord during tsDCS. They are important to guide the design of clinical tsDCS protocols that optimize stimulation of application-specific spinal targets.

  11. Effective inactivation of a wide range of viruses by pasteurization.

    Science.gov (United States)

    Gröner, Albrecht; Broumis, Connie; Fang, Randel; Nowak, Thomas; Popp, Birgit; Schäfer, Wolfram; Roth, Nathan J

    2018-01-01

    Careful selection and testing of plasma reduces the risk of blood-borne viruses in the starting material for plasma-derived products. Furthermore, effective measures such as pasteurization at 60°C for 10 hours have been implemented in the manufacturing process of therapeutic plasma proteins such as human albumin, coagulation factors, immunoglobulins, and enzyme inhibitors to inactivate blood-borne viruses of concern. A comprehensive compilation of the virus reduction capacity of pasteurization is presented including the effect of stabilizers used to protect the therapeutic protein from modifications during heat treatment. The virus inactivation kinetics of pasteurization for a broad range of viruses were evaluated in the relevant intermediates from more than 15 different plasma manufacturing processes. Studies were carried out under the routine manufacturing target variables, such as temperature and product-specific stabilizer composition. Additional studies were also performed under robustness conditions, that is, outside production specifications. The data demonstrate that pasteurization inactivates a wide range of enveloped and nonenveloped viruses of diverse physicochemical characteristics. After a maximum of 6 hours' incubation, no residual infectivity could be detected for the majority of enveloped viruses. Effective inactivation of a range of nonenveloped viruses, with the exception of nonhuman parvoviruses, was documented. Pasteurization is a very robust and reliable virus inactivation method with a broad effectiveness against known blood-borne pathogens and emerging or potentially emerging viruses. Pasteurization has proven itself to be a highly effective step, in combination with other complementary safety measures, toward assuring the virus safety of final product. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  12. Spinal cord injury below-level neuropathic pain relief with dorsal root entry zone microcoagulation performed caudal to level of complete spinal cord transection.

    Science.gov (United States)

    Falci, Scott; Indeck, Charlotte; Barnkow, Dave

    2018-06-01

    OBJECTIVE Surgically created lesions of the spinal cord dorsal root entry zone (DREZ) to relieve central pain after spinal cord injury (SCI) have historically been performed at and cephalad to, but not below, the level of SCI. This study was initiated to investigate the validity of 3 proposed concepts regarding the DREZ in SCI central pain: 1) The spinal cord DREZ caudal to the level of SCI can be a primary generator of SCI below-level central pain. 2) Neuronal transmission from a DREZ that generates SCI below-level central pain to brain pain centers can be primarily through sympathetic nervous system (SNS) pathways. 3) Perceived SCI below-level central pain follows a unique somatotopic map of DREZ pain-generators. METHODS Three unique patients with both intractable SCI below-level central pain and complete spinal cord transection at the level of SCI were identified. All 3 patients had previously undergone surgical intervention to their spinal cords-only cephalad to the level of spinal cord transection-with either DREZ microcoagulation or cyst shunting, in failed attempts to relieve their SCI below-level central pain. Subsequent to these surgeries, DREZ lesioning of the spinal cord solely caudal to the level of complete spinal cord transection was performed using electrical intramedullary guidance. The follow-up period ranged from 1 1/2 to 11 years. RESULTS All 3 patients in this study had complete or near-complete relief of all below-level neuropathic pain. The analyzed electrical data confirmed and enhanced a previously proposed somatotopic map of SCI below-level DREZ pain generators. CONCLUSIONS The results of this study support the following hypotheses. 1) The spinal cord DREZ caudal to the level of SCI can be a primary generator of SCI below-level central pain. 2) Neuronal transmission from a DREZ that generates SCI below-level central pain to brain pain centers can be primarily through SNS pathways. 3) Perceived SCI below-level central pain follows a unique

  13. The high dynamic range pixel array detector (HDR-PAD): Concept and design

    Energy Technology Data Exchange (ETDEWEB)

    Shanks, Katherine S.; Philipp, Hugh T.; Weiss, Joel T.; Becker, Julian; Tate, Mark W. [Laboratory of Atomic and Solid State Physics, Cornell University, Ithaca, NY 14853 (United States); Gruner, Sol M., E-mail: smg26@cornell.edu [Laboratory of Atomic and Solid State Physics, Cornell University, Ithaca, NY 14853 (United States); Cornell High Energy Synchrotron Source (CHESS), Cornell University, Ithaca, NY 14853 (United States)

    2016-07-27

    Experiments at storage ring light sources as well as at next-generation light sources increasingly require detectors capable of high dynamic range operation, combining low-noise detection of single photons with large pixel well depth. XFEL sources in particular provide pulse intensities sufficiently high that a purely photon-counting approach is impractical. The High Dynamic Range Pixel Array Detector (HDR-PAD) project aims to provide a dynamic range extending from single-photon sensitivity to 10{sup 6} photons/pixel in a single XFEL pulse while maintaining the ability to tolerate a sustained flux of 10{sup 11} ph/s/pixel at a storage ring source. Achieving these goals involves the development of fast pixel front-end electronics as well as, in the XFEL case, leveraging the delayed charge collection due to plasma effects in the sensor. A first prototype of essential electronic components of the HDR-PAD readout ASIC, exploring different options for the pixel front-end, has been fabricated. Here, the HDR-PAD concept and preliminary design will be described.

  14. Transmitted wavefront testing with large dynamic range based on computer-aided deflectometry

    Science.gov (United States)

    Wang, Daodang; Xu, Ping; Gong, Zhidong; Xie, Zhongmin; Liang, Rongguang; Xu, Xinke; Kong, Ming; Zhao, Jun

    2018-06-01

    The transmitted wavefront testing technique is demanded for the performance evaluation of transmission optics and transparent glass, in which the achievable dynamic range is a key issue. A computer-aided deflectometric testing method with fringe projection is proposed for the accurate testing of transmitted wavefronts with a large dynamic range. Ray tracing of the modeled testing system is carried out to achieve the virtual ‘null’ testing of transmitted wavefront aberrations. The ray aberration is obtained from the ray tracing result and measured slope, with which the test wavefront aberration can be reconstructed. To eliminate testing system modeling errors, a system geometry calibration based on computer-aided reverse optimization is applied to realize accurate testing. Both numerical simulation and experiments have been carried out to demonstrate the feasibility and high accuracy of the proposed testing method. The proposed testing method can achieve a large dynamic range compared with the interferometric method, providing a simple, low-cost and accurate way for the testing of transmitted wavefronts from various kinds of optics and a large amount of industrial transmission elements.

  15. Spinal cord stimulation: Background and clinical application

    DEFF Research Database (Denmark)

    Meier, Kaare

    2014-01-01

    a number of contacts capable of delivering a weak electrical current to the spinal cord, evoking a feeling of peripheral paresthesia. With correct indication and if implanted by an experienced implanter, success rates generally are in the range of about 50–75%. Common indications include complex regional...

  16. Spinal cord stimulation therapy for gait dysfunction in advanced Parkinson's disease patients.

    Science.gov (United States)

    Samotus, Olivia; Parrent, Andrew; Jog, Mandar

    2018-02-14

    Benefits of dopaminergic therapy and deep brain stimulation are limited and unpredictable for axial symptoms in Parkinson's disease. Dorsal spinal cord stimulation may be a new therapeutic approach. The objective of this study was to investigate the therapeutic effect of spinal cord stimulation on gait including freezing of gait in advanced PD patients. Five male PD participants with significant gait disturbances and freezing of gait underwent midthoracic spinal cord stimulation. Spinal cord stimulation combinations (200-500 μs/30-130 Hz) at suprathreshold intensity were tested over a 1- to 4-month period, and the effects of spinal cord stimulation were studied 6 months after spinal cord stimulation surgery. Protokinetics Walkway measured gait parameters. Z scores per gait variable established each participant's best spinal cord stimulation setting. Timed sit-to-stand and automated freezing-of-gait detection using foot pressures were analyzed. Freezing of Gait Questionnaire (FOG-Q), UPDRS motor items, and activities-specific balance confidence scale were completed at each study visit. Spinal cord stimulation setting combinations of 300-400 μs/30-130 Hz provided gait improvements. Although on-medication/on-stimulation at 6 months, mean step length, stride velocity, and sit-to-stand improved by 38.8%, 42.3%, and 50.3%, respectively, mean UPDRS, Freezing of Gait Questionnaire, and activities-specific balance confidence scale scores improved by 33.5%, 26.8%, and 71.4%, respectively. The mean number of freezing-of-gait episodes reduced significantly from 16 presurgery to 0 at 6 months while patients were on levodopa and off stimulation. By using objective measures to detect dynamic gait characteristics, the therapeutic potential of spinal cord stimulation was optimized to each participant's characteristics. This pilot study demonstrated the safety and significant therapeutic outcome of spinal cord stimulation in advanced PD patients, and thus a larger and longer

  17. Experimental study of dynamic diffusion tensor imaging in spinal cord of goats under persistent compression

    International Nuclear Information System (INIS)

    Liu Jicun; Liu Huaijun; He Dan; Huang Boyuan; Cui Caixia; Wang Zhihong; Xu Yingjin

    2009-01-01

    Objective: To explore the dynamic changes of diffusion tensor imaging (DTI) in spinal cord of goats with persistent compression injury. Methods: Eighteen goats weighted 20-25 kg were divided into three groups with completely random design: A, B and C. A balloon catheter was inserted into the epidural space at C3-4 level via intervertabral foramen for each goat. The balloon was inflated by injection of variable volumes of saline in group A and B 10 days following operation. The volume of saline was 0.3 ml in group A and 0.2 ml in group B, respectively. The compression sustained for 40 days. Group C served as uncompressed control without injection of saline. The locomotor rating score was applied to each group. Conventional MRI and DTI were performed. The apparent diffusion coefficient (ADC)and fractional anisotropy(FA) values were measured. Histopathological assessments of the compressed spinal cord were performed 50 days following operation with light microscope and transmission electron microscopy. Results: Before operation, the locomotor rating score was 5, the ADC value was (1.23 ± 0.05) x 10 -3 mm 2 /s and the FA value was (0.72 ± 0.05) each group. Of six goats in Group A, the locomotor rating score severely decreased and reached (1.5 ± 0.4)on the 40 th day after compression. The ADC value at compression site decreased soon and reached the minimum (0.75 ± 0.04) x 10 -3 mm 2 /s on the 5 th day after compression. Then the ADC value increased gradually, restored normal on the 10 th day or so, then became markedly higher than normal and reached (1.61±0.05) x 10 -3 mm 2 /s on the 40 th day. The FA value at compression site decreased soon, reached (0.54±0.04)on the 1st day, then decreased gradually and reached (0.43± 0.05) on the 40 th day. It appeared high signal intensity on T 2 WI on the 10 th day. In Group B, the locomotor rating score was moderately decreased and reached (3.4 ± 0.5) on the 40 th day. The ADC value at compression site decreased slightly

  18. The mechanical behavior of metal alloys with grain size distribution in a wide range of strain rates

    Science.gov (United States)

    Skripnyak, V. A.; Skripnyak, V. V.; Skripnyak, E. G.

    2017-12-01

    The paper discusses a multiscale simulation approach for the construction of grain structure of metals and alloys, providing high tensile strength with ductility. This work compares the mechanical behavior of light alloys and the influence of the grain size distribution in a wide range of strain rates. The influence of the grain size distribution on the inelastic deformation and fracture of aluminium and magnesium alloys is investigated by computer simulations in a wide range of strain rates. It is shown that the yield stress depends on the logarithm of the normalized strain rate for light alloys with a bimodal grain distribution and coarse-grained structure.

  19. Non osseous intra-spinal tumors in children and adolescents: spinal column deformity (in french)

    International Nuclear Information System (INIS)

    Ghanem, I.; Zeller, R.; Dubousset, J.

    1997-01-01

    Purpose of the study. The delay in diagnosis of spinal tumors is not rare. The chief complaint may include pain, walking disability and spinal or limb deformities. The purpose of our study is to analyze the spinal deformities associated with non osseous intra-spinal tumors, to assess the complications of treatment, and to set out a preventive protocol. Methods. The incidence and pattern of spinal deformity was assessed before tumor treatment and ultimately after laminectomy or osteoplastic laminotomy (or lamino-plasty). Results. Among the 9 cases with preexisting spinal deformity, the curve magnitude increased after laminectomy in 4. A kyphotic, kyphoscoliotic or scoliotic deformity developed in 18 cases after surgery for tumor resection. Among these 18 patients, only one had bad an adequate osteoplastic laminotomy. The treatment of spinal deformities was surgical in 12 cases, and done by either posterior or anterior and posterior combined arthrodesis. Discussion. Spinal deformity may be the main complaint of a patient who has intraspinal tumor. Prevention of post-laminectomy spinal deformity is mandatory, and could be done by osteoplastic laminotomy and the use of a brace during a minimum period of 4 to 6 months after surgery. Conclusion. Diagnosis of intraspinal tumors in children and adolescents should be done early, and lamino-arthrectomy should be replaced by osteoplastic laminotomy. (authors)

  20. Calcium imaging of living astrocytes in the mouse spinal cord following sensory stimulation.

    Science.gov (United States)

    Cirillo, Giovanni; De Luca, Daniele; Papa, Michele

    2012-01-01

    Astrocytic Ca(2+) dynamics have been extensively studied in ex vivo models; however, the recent development of two-photon microscopy and astrocyte-specific labeling has allowed the study of Ca(2+) signaling in living central nervous system. Ca(2+) waves in astrocytes have been described in cultured cells and slice preparations, but evidence for astrocytic activation during sensory activity is lacking. There are currently few methods to image living spinal cord: breathing and heart-beating artifacts have impeded the widespread application of this technique. We here imaged the living spinal cord by two-photon microscopy in C57BL6/J mice. Through pressurized injection, we specifically loaded spinal astrocytes using the red fluorescent dye sulforhodamine 101 (SR101) and imaged astrocytic Ca(2+) levels with Oregon-Green BAPTA-1 (OGB). Then, we studied astrocytic Ca(2+) levels at rest and after right electrical hind paw stimulation. Sensory stimulation significantly increased astrocytic Ca(2+) levels within the superficial dorsal horn of the spinal cord compared to rest. In conclusion, in vivo morphofunctional imaging of living astrocytes in spinal cord revealed that astrocytes actively participate to sensory stimulation.

  1. Chronic spinal subdural hematoma

    International Nuclear Information System (INIS)

    Hagen, T.; Lensch, T.

    2008-01-01

    Compared with spinal epidural hematomas, spinal subdural hematomas are rare; chronic forms are even more uncommon. These hematomas are associated not only with lumbar puncture and spinal trauma, but also with coagulopathies, vascular malformations and tumors. Compression of the spinal cord and the cauda equina means that the patients develop increasing back or radicular pain, followed by paraparesis and bladder and bowel paralysis, so that in most cases surgical decompression is carried out. On magnetic resonance imaging these hematomas present as thoracic or lumbar subdural masses, their signal intensity varying with the age of the hematoma. We report the clinical course and the findings revealed by imaging that led to the diagnosis in three cases of chronic spinal subdural hematoma. (orig.) [de

  2. Diversity of sharp-wave–ripple LFP signatures reveals differentiated brain-wide dynamical events

    Science.gov (United States)

    Ramirez-Villegas, Juan F.; Logothetis, Nikos K.; Besserve, Michel

    2015-01-01

    Sharp-wave–ripple (SPW-R) complexes are believed to mediate memory reactivation, transfer, and consolidation. However, their underlying neuronal dynamics at multiple scales remains poorly understood. Using concurrent hippocampal local field potential (LFP) recordings and functional MRI (fMRI), we study local changes in neuronal activity during SPW-R episodes and their brain-wide correlates. Analysis of the temporal alignment between SPW and ripple components reveals well-differentiated SPW-R subtypes in the CA1 LFP. SPW-R–triggered fMRI maps show that ripples aligned to the positive peak of their SPWs have enhanced neocortical metabolic up-regulation. In contrast, ripples occurring at the trough of their SPWs relate to weaker neocortical up-regulation and absent subcortical down-regulation, indicating differentiated involvement of neuromodulatory pathways in the ripple phenomenon mediated by long-range interactions. To our knowledge, this study provides the first evidence for the existence of SPW-R subtypes with differentiated CA1 activity and metabolic correlates in related brain areas, possibly serving different memory functions. PMID:26540729

  3. Diversity of sharp-wave-ripple LFP signatures reveals differentiated brain-wide dynamical events.

    Science.gov (United States)

    Ramirez-Villegas, Juan F; Logothetis, Nikos K; Besserve, Michel

    2015-11-17

    Sharp-wave-ripple (SPW-R) complexes are believed to mediate memory reactivation, transfer, and consolidation. However, their underlying neuronal dynamics at multiple scales remains poorly understood. Using concurrent hippocampal local field potential (LFP) recordings and functional MRI (fMRI), we study local changes in neuronal activity during SPW-R episodes and their brain-wide correlates. Analysis of the temporal alignment between SPW and ripple components reveals well-differentiated SPW-R subtypes in the CA1 LFP. SPW-R-triggered fMRI maps show that ripples aligned to the positive peak of their SPWs have enhanced neocortical metabolic up-regulation. In contrast, ripples occurring at the trough of their SPWs relate to weaker neocortical up-regulation and absent subcortical down-regulation, indicating differentiated involvement of neuromodulatory pathways in the ripple phenomenon mediated by long-range interactions. To our knowledge, this study provides the first evidence for the existence of SPW-R subtypes with differentiated CA1 activity and metabolic correlates in related brain areas, possibly serving different memory functions.

  4. A very rare spinal cord tumor primary spinal oligodendroglioma: A review of sixty cases in the literature

    Directory of Open Access Journals (Sweden)

    Askin Esen Hasturk

    2017-01-01

    Full Text Available Literature review. In this study, we evaluated a case of primary spinal oligodendroglioma (PSO with a rare localization between L3 and S2, and also examined sixty cases in the literature in terms of demographic characteristics, clinical, radiological, and histopathological characteristics, and treatment planning. A case of PSO has been presented, and the relevant literature between 1931 and 2016 was reviewed. A total of 57 papers regarding PSO were found and utilized in this review. The main treatment options include radical surgical excision with neuromonitoring, followed by radiotherapy. Despite these treatment protocols, the relapse rate is high, and treatment does not significantly prolong survival. Oligodendrogliomas are rare among the primary spinal cord tumors. Oligodendrogliomas are predominantly found in the cervical spinal cord, thoracic spinal cord, or junctions during childhood and adulthood. Extension to the sacral region, inferior to the Conus, is very rare. Furthermore, of the sixty cases in the literature, the case we present here is the first to be reported in this particular age group. These localizations usually occur in the pediatric age group and after relapses. While for a limited number of cases the oligodendroglioma initiates in the thoracic region and reaches as far as L2, we encountered a case of an oligodendroglioma within the range of L3 to S2. Clinical findings are observed in accordance with location, and magnetic resonance imaging is the gold standard for diagnosis.

  5. Imaging procedures in spinal infectious diseases

    International Nuclear Information System (INIS)

    Rodiek, S.O.

    2001-01-01

    A targeted successful treatment of spinal infectious diseases requires clinical and laboratory data that are completed by the contribution of imaging procedures. Neuroimaging only provides essential informations on the correct topography, localisation, acuity and differential diagnosis of spinal infectious lesions. MRI with its sensitivity concerning soft tissue lesions is a useful tool in detecting infectious alterations of spinal bone marrow, intervertebral disks, leptomeninges and the spinal cord itself. Crucial imaging patterns of typical spinal infections are displayed and illustrated by clinical case studies. We present pyogenic, granulomatous and postoperative variants of spondylodicitis, spinal epidural abscess, spinal meningitis and spinal cord infections. The importance of intravenous contrastmedia application is pointed out. (orig.) [de

  6. Perceptual Effects of Dynamic Range Compression in Popular Music Recordings

    DEFF Research Database (Denmark)

    Hjortkjær, Jens; Walther-Hansen, Mads

    2014-01-01

    There is a widespread belief that the increasing use of dynamic range compression in music mastering (the loudnesswar) deteriorates sound quality but experimental evidence of perceptual effects is lacking. In this study, normal hearing listeners were asked to evaluate popular music recordings in ...

  7. Dimensions of the lumbar spinal canal: variations and correlations with somatometric parameters using CT

    Energy Technology Data Exchange (ETDEWEB)

    Karantanas, A.H. [Department of CT-MRI, Larissa General Hospital (Greece); Zibis, A.H.; Papaliaga, M.; Georgiou, E.; Rousogiannis, S. [Larissa Medical School, University of Thessaly, Larissa (Greece)

    1998-12-01

    The aim of this study was to investigate the correlation of vertebral dimensions with somatometric parameters in patients without clinical symptoms and radiological signs of central lumbar spinal stenosis. One hundred patients presenting with low back pain or sciatica were studied with CT. In each of the L3, L4 and L5 vertebra three slices were taken with the following measurements: 1. Slice through the intervertebral disc: (a) spinal canal area; (b) interarticular diameter; (c) interligamentous diameter. 2. Slice below the vertebral arcus: (a) dural sac area; (b) vertebral body area. 3. Pediculolaminar level: (a) anteroposterior diameter and interpedicular diameter of the spinal canal; (b) spinal canal area; (c) width of the lateral recesses. The Jones-Thomson index was also estimated. The results of the present study showed that there is a statistically significant correlation of height, weight and age with various vertebral indices. The conventional, widely accepted, anteroposterior diameter of 11.5 mm of the lumbar spinal canal is independent of somatometric parameters, and it is the only constant measurement for the estimation of lumbar spinal stenosis with a single value. The present study suggests that there are variations of the dimensions of the lumbar spinal canal and correlations with height, weight and age of the patient. (orig.) With 1 fig., 6 tabs., 24 refs.

  8. Dose Measurements of Parotid Glands and Spinal Cord in Conventional Treatment of Nasopharyngeal Carcinoma Using RANDO Phantom and Thermoluminescent Dosimeters

    Directory of Open Access Journals (Sweden)

    Mohammad Taghi Bahreyni Toossi

    2015-07-01

    Full Text Available Introduction Radiotherapy is regarded as the first treatment of choice for nasopharyngeal carcinoma. Despite the advantages of radiotherapy, patients may suffer from a wide range of side-effects due to the presence of many sensitive normal tissues in these regions. If the absorbed dose exceeds the tolerance level in parotid glands and the spinal cord, myelopathy, Lhermitte's sign and xerostomia cannot be avoided. Materials and Methods The head and neck of a RANDO phantom (reference man, which was regarded as a hypothetical patient with nasopharyngeal carcinoma was evaluated. The full course of treatment consisted of three phases. At the beginning of each phase, an oncologist marked conventional fields on the RANDO phantom using a simulator. For measuring the absorbed dose, Thermoluminescent Dosimeters(TLD chips (TLD-100 were utilized.The absorbed dose by TLDs was read by Harshaw 3500 TLD reader. Results The total absorbed dose was calculated by measuring the absorbed dose in each phase, multiplied by the fraction numbers of each phase; the obtained values were summed up. The results showed that the received doses by spinal cord ranged from 15.24 to 54.56 Gy. Also, the absorbed dose of parotid glands was approximately 39.23 Gy. Conclusion Considering the minimum tolerance dose the absorbed doses in the spinal cord and parotid glands were above the tolerance level. The incidence rate of xerostomia and myelopathy were higher in patients, treated by conventional methods.

  9. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... the spinal cord work? play_arrow Why is the level of a spinal cord injury important? play_arrow What role does “compression” play in a spinal cord injury? play_arrow Why are high-dose steroids often used right after an injury? play_arrow What is meant ...

  10. Encounter success of free-ranging marine predator movements across a dynamic prey landscape.

    Science.gov (United States)

    Sims, David W; Witt, Matthew J; Richardson, Anthony J; Southall, Emily J; Metcalfe, Julian D

    2006-05-22

    Movements of wide-ranging top predators can now be studied effectively using satellite and archival telemetry. However, the motivations underlying movements remain difficult to determine because trajectories are seldom related to key biological gradients, such as changing prey distributions. Here, we use a dynamic prey landscape of zooplankton biomass in the north-east Atlantic Ocean to examine active habitat selection in the plankton-feeding basking shark Cetorhinus maximus. The relative success of shark searches across this landscape was examined by comparing prey biomass encountered by sharks with encounters by random-walk simulations of 'model' sharks. Movements of transmitter-tagged sharks monitored for 964 days (16754 km estimated minimum distance) were concentrated on the European continental shelf in areas characterized by high seasonal productivity and complex prey distributions. We show movements by adult and sub-adult sharks yielded consistently higher prey encounter rates than 90% of random-walk simulations. Behavioural patterns were consistent with basking sharks using search tactics structured across multiple scales to exploit the richest prey areas available in preferred habitats. Simple behavioural rules based on learned responses to previously encountered prey distributions may explain the high performances. This study highlights how dynamic prey landscapes enable active habitat selection in large predators to be investigated from a trophic perspective, an approach that may inform conservation by identifying critical habitat of vulnerable species.

  11. Development of GM tube electronic personal dosimeter with wide range and multi-purposes

    International Nuclear Information System (INIS)

    Li Jing; Weng Puyu; Chen Mingjun; Hu Zunsu; Huang Chenguang; Lei Jindian

    2003-01-01

    This paper describes the main design features and basic properties of a GM tube electronic personal dosimeter with wide range and multi-purposes. the dosimeter can display dose-rate or accumulative dose or the maximum dose-rate, record accumulative dose and the maximum dose-rate as well as the time of its appearance and at most 160 historical dose values within 8 h. All recorded data can directly be sent to PC by the infrared communication

  12. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  13. Spinal cord stimulation

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007560.htm Spinal cord stimulation To use the sharing features on this page, please enable JavaScript. Spinal cord stimulation is a treatment for pain that uses ...

  14. MANAGEMENT OF LUMBAR SPINAL CANAL STENOSIS

    Directory of Open Access Journals (Sweden)

    Mukhergee G. S

    2016-06-01

    degenerative. This process is most commonly localised to the facet joints and ligamentum flavum, with the resultant arthritic changes in the joints visible on radiographic studies. Frequently, these abnormalities are symmetrical and bilateral. The L4-L5 level is the most commonly involved, followed by L5-S1 and L3-L4 disc herniation and spondylolisthesis may exacerbate the narrowing further. 1. METHODS This study was taken up to evaluate the management of lumbar spinal canal stenosis cases. The study was conducted from May 2012 to October 2014: A total of 86 patients of 55-70 age groups with degenerative LCS were followed prospectively from May 2012 to October 2014. All the treatment methods were explained to patients and treatment method was determined by patient’s choice. The sample is divided into two groups 42 surgical and 44 conservative based on patient’s preference. MEASUREMENT OF OUTCOME Outcomes were measures of bodily pain and physical function on the medical outcomes study 36-item short-Form General Health Study (SF-36 22-25 and on the modified Oswestry Disability Index 26 measured at 6 weeks, 3 months, 6 months, and 1 year and 18 months. SF-36 scores range from 0 to 100 with higher scores indicating less severe symptoms. The Oswestry Disability Index ranges from 0 to 100, with lower scores indicating less severe symptoms. STUDY INTERVENTION The protocol surgery was standard posterior decompressive laminectomy operated by three surgeons. The type of nonsurgical care included physical therapy (68% of patients, epidural injections (56%, the use of anti-inflammatory drugs (55% and use of opioid analgesics (27%. Informed consent was taken from every patient after explaining the particulars of study interventions. In this study, 82% patients (n=70 were in age group 50-59 years with an average age of 50.2 years with a total sample size of 86 patients followed by 60-69 years age group. Both the surgical and conservative groups had similar sex distribution. Initially

  15. Imaging of extradural spinal lesions; Bildgebung extraduraler Raumforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Ahlhelm, F.; Schulte-Altedorneburg, G.; Naumann, N.; Reith, W. (Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar); Nabhan, A. (Universitaetsklinikum des Saarlandes, Homburg/Saar, Klinik fuer Allgemeine und Spezielle Neurochirurgie)

    2006-12-15

    There is a wide variety of spinal extradural tumors. In addition to real neoplasms, degenerative diseases, congenital abnormalities and inflammatory disorders can be causes of extradural masses. Due to the bony boundary of the spinal canal, both benign as well as malignant masses can cause progressive neurological deficits including paraplegia. Most of the spinal tumors are benign (hemangioma of the vertebral body, degenerative diseases). In younger patients congenital abnormalities and primary tumors of the spine have to be considered, whereas in adults the list of differential diagnoses should include secondary malignancies such as metastases and lymphomas as well as metabolic disorders such as osteoporotic vertebral compression fracture and Paget's disease. Cross-sectional imaging techniques such as magnetic resonance imaging (MRI) and computed tomography (CT) of the spine often help to make a specific diagnosis of extradural spinal lesions and represent important tools for tumor staging and preoperative evaluation. (orig.) Das Spektrum der spinalen extraduralen Tumoren ist sehr gross. Neben echten Neoplasien koennen auch degenerative Veraenderungen und Anlagestoerungen sowie entzuendliche Veraenderungen Ursachen einer extraduralen Raumforderung sein. Aufgrund der knoechernen Begrenzung des Spinalkanals koennen neben Malignomen auch benigne Tumoren und degenerative spinale Veraenderungen zu progredienten neurologischen Ausfallsymptomen (einschliesslich Querschnittsymptomatik) fuehren. Die ueberwiegende Mehrzahl der extraduralen Raumforderungen der Wirbelsaeule ist benigne (Haemangiom des Wirbelkoerpers, degenerative Erkrankungen). Bei jungen Patienten sind Anlagestoerungen und primaere Wirbelsaeulentumoren zu beruecksichtigen, wogegen beim Erwachsenen an sekundaere Malignome, wie Metastasen und Lymphome sowie eine metabolische Erkrankung, wie die osteoporotische Wirbelkoerpersinterungsfraktur oder der Morbus Paget, differenzialdiagnostisch gedacht werden

  16. Interactions between vegetation, atmospheric turbulence and clouds under a wide range of background wind conditions

    NARCIS (Netherlands)

    Sikma, M.; Ouwersloot, H.G.; Pedruzo-Bagazgoitia, X.; Heerwaarden, van C.C.; Vilà-Guerau de Arellano, J.

    2018-01-01

    The effects of plant responses to cumulus (Cu) cloud shading are studied from free convective to shear-driven boundary-layer conditions. By using a large-eddy simulation (LES) coupled to a plant physiology embedded land-surface submodel, we study the vegetation-cloud feedbacks for a wide range (44)

  17. Spinal Cord Injury 101

    Medline Plus

    Full Text Available ... injury? play_arrow How does the spinal cord work? play_arrow Why is the level of a spinal cord injury important? play_arrow What role does “compression” play in a spinal cord injury? play_arrow Why are high-dose steroids often used right after an injury? play_arrow What is meant ...

  18. Electron response of some low-Z scintillators in wide energy range

    International Nuclear Information System (INIS)

    Swiderski, L; Marcinkowski, R; Moszynski, M; Czarnacki, W; Szawlowski, M; Szczesniak, T; Pausch, G; Plettner, C; Roemer, K

    2012-01-01

    Light yield nonproportionality and the intrinsic resolution of some low atomic number scintillators were studied by means of the Wide Angle Compton Coincidence (WACC) technique. The plastic and liquid scintillator response to Compton electrons was measured in the energy range of 10 keV up to 4 MeV, whereas a CaF 2 :Eu sample was scanned from 3 keV up to 1 MeV. The nonproportionality of the CaF 2 :Eu light yield has characteristics typical for inorganic scintillators of the multivalent halides group, whereas tested organic scintillators show steeply increasing nonproportionality without saturation point. This is in contrast to the behavior of all known inorganic scintillators having their nonproportionality curves at saturation above energies between tens and several hundred keV.

  19. Electron response of some low-Z scintillators in wide energy range

    Science.gov (United States)

    Swiderski, L.; Marcinkowski, R.; Moszynski, M.; Czarnacki, W.; Szawlowski, M.; Szczesniak, T.; Pausch, G.; Plettner, C.; Roemer, K.

    2012-06-01

    Light yield nonproportionality and the intrinsic resolution of some low atomic number scintillators were studied by means of the Wide Angle Compton Coincidence (WACC) technique. The plastic and liquid scintillator response to Compton electrons was measured in the energy range of 10 keV up to 4 MeV, whereas a CaF2:Eu sample was scanned from 3 keV up to 1 MeV. The nonproportionality of the CaF2:Eu light yield has characteristics typical for inorganic scintillators of the multivalent halides group, whereas tested organic scintillators show steeply increasing nonproportionality without saturation point. This is in contrast to the behavior of all known inorganic scintillators having their nonproportionality curves at saturation above energies between tens and several hundred keV.

  20. Fast, High Resolution, and Wide Modulus Range Nanomechanical Mapping with Bimodal Tapping Mode.

    Science.gov (United States)

    Kocun, Marta; Labuda, Aleksander; Meinhold, Waiman; Revenko, Irène; Proksch, Roger

    2017-10-24

    Tapping mode atomic force microscopy (AFM), also known as amplitude modulated (AM) or AC mode, is a proven, reliable, and gentle imaging mode with widespread applications. Over the several decades that tapping mode has been in use, quantification of tip-sample mechanical properties such as stiffness has remained elusive. Bimodal tapping mode keeps the advantages of single-frequency tapping mode while extending the technique by driving and measuring an additional resonant mode of the cantilever. The simultaneously measured observables of this additional resonance provide the additional information necessary to extract quantitative nanomechanical information about the tip-sample mechanics. Specifically, driving the higher cantilever resonance in a frequency modulated (FM) mode allows direct measurement of the tip-sample interaction stiffness and, with appropriate modeling, the set point-independent local elastic modulus. Here we discuss the advantages of bimodal tapping, coined AM-FM imaging, for modulus mapping. Results are presented for samples over a wide modulus range, from a compliant gel (∼100 MPa) to stiff materials (∼100 GPa), with the same type of cantilever. We also show high-resolution (subnanometer) stiffness mapping of individual molecules in semicrystalline polymers and of DNA in fluid. Combined with the ability to remain quantitative even at line scan rates of nearly 40 Hz, the results demonstrate the versatility of AM-FM imaging for nanomechanical characterization in a wide range of applications.

  1. Spinal Trauma is Never without Sin: A Tetraplegia Patient Presented Without any Symptoms

    Directory of Open Access Journals (Sweden)

    Melis EFEOGLU

    2014-12-01

    Full Text Available SUMMARY: Spinal cord injuries are amongst the most dangerous injuries, leading to high mortality and morbidity. Injured patients are occasionally faced with life-threatening complications and quality-of-life changing neurological deficits. Thoracic and cervical spinal segments are the most effected sites of injury and a wide range of complications including paraplegia, respiratory and cardiovascular compromise secondary to autonomic dysfunction or tetraplegia may ensue. We aim to draw attention to the progressive nature of the neurological deficits in a patient admitted asymptomatically. Also, we would like to discuss the importance of swift diagnosis and management in such patients. In asymptomatic patients in whom no fractures are diagnosed with CT scans, a neurological examination should be repeated several times to exclude any neurological injuries that were missed. MRI should be ordered in an emergency setting even though it is not frequently used as a diagnostic modality. This should be done especially in patients without any fractures on CT but with neurological signs. ÖZET: Spinal kord yaralanmaları yüksek mortalite ve sakatlanma oranlarına neden olan en tehlikeli yaralanmalar arasında sayılmaktadır. Etkilenen hastalarda sıklıkla yaşamı tehdit edici komplikasyonlar ve hastanın hayat kalitesini etkileyen nörolojik bozukluklar gelişebilmektedir. Torakal ve servikal segmentler en sık etkilenen yaralanma yerleri olup, hastalarda otonom disfonksiyona ikincil parapleji, solunumsal ve kardiyovasküler bozukluklar gelişebilir ya da tetrapleji görülebilir. Bu olgu sunumuyla, semptomsuz olarak başvuran bir hastanın nörolojik bozukluklarının ilerleyici doğasına dikkat çekmek istiyoruz. Ayrıca, bu tip hastalarda hızlı tanı ve yönetimin önemini tartışmak istemekteyiz. Semptomsuz olarak başvuran ve bilgisayarlı tomografilerinde kırık saptanmayan hastalarda nörolojik muayene sık aralıklarla tekrarlanarak

  2. Wide wavelength range tunable one-dimensional silicon nitride nano-grating guided mode resonance filter based on azimuthal rotation

    Directory of Open Access Journals (Sweden)

    Ryoji Yukino

    2017-01-01

    Full Text Available We describe wavelength tuning in a one dimensional (1D silicon nitride nano-grating guided mode resonance (GMR structure under conical mounting configuration of the device. When the GMR structure is rotated about the axis perpendicular to the surface of the device (azimuthal rotation for light incident at oblique angles, the conditions for resonance are different than for conventional GMR structures under classical mounting. These resonance conditions enable tuning of the GMR peak position over a wide range of wavelengths. We experimental demonstrate tuning over a range of 375 nm between 500 nm˜875 nm. We present a theoretical model to explain the resonance conditions observed in our experiments and predict the peak positions with show excellent agreement with experiments. Our method for tuning wavelengths is simpler and more efficient than conventional procedures that employ variations in the design parameters of structures or conical mounting of two-dimensional (2D GMR structures and enables a single 1D GMR device to function as a high efficiency wavelength filter over a wide range of wavelengths. We expect tunable filters based on this technique to be applicable in a wide range of fields including astronomy and biomedical imaging.

  3. Seasonality in cholera dynamics : a rainfall-driven model explains the wide range of patterns of an infectious disease in endemic areas

    Science.gov (United States)

    Baracchini, Theo; Pascual, Mercedes; King, Aaron A.; Bouma, Menno J.; Bertuzzo, Enrico; Rinaldo, Andrea

    2015-04-01

    An explanation for the spatial variability of seasonal cholera patterns has remained an unresolved problem in tropical medicine te{pascual_2002}. Previous studies addressing the role of climate drivers in disease dynamics have focused on interannual variability and modelled seasonality as given te{king_nature}. Explanations for seasonality have relied on complex environmental interactions that vary with spatial location (involving regional hydrological models te{bertuzzo_2012}, river discharge, sea surface temperature, and plankton blooms). Thus, no simple and unified theory based on local climate variables has been formulated te{emch_2008}, leaving our understanding of seasonal variations of cholera outbreaks in different regions of the world incomplete. Through the analysis of a unique historical dataset containing 50 years of monthly meteorological, demographic and epidemiological records, we propose a mechanistic, SIR-based stochastic model for the population dynamics of cholera driven by local rainfall and temperature that is able to capture the full range of seasonal patterns in this large estuarine region, which encompasses the variety of patterns worldwide. Parameter inference was implemented via new statistical methods that allow the computation of maximum-likelihood estimates for partially observed Markov processes through sequential Monte-Carlo te{ionides_2011}. Such a model may provide a unprecedented opportunity to gain insights on the conditions and factors responsible for endemicity around the globe, and therefore, to also revise our understanding of the ecology of Vibrio cholerae. Results indicate that the hydrological regime is a decisive driver determining the seasonal dynamics of cholera. It was found that rainfall and longer water residence times tend to buffer the propagation of the disease in wet regions due to a dilution effect, while also enhancing cholera incidence in dry regions. This indicates that overall water levels matter and appear

  4. Useful properties of spinal circuits for learning and performing planar reaches

    Science.gov (United States)

    Tsianos, George A.; Goodner, Jared; Loeb, Gerald E.

    2014-10-01

    Objective. We developed a detailed model of the spinal circuitry plus musculoskeletal system (SC + MS) for the primate arm and investigated its role in sensorimotor control, learning and storing of movement repertoires. Approach. Recently developed models of spinal circuit connectivity, neurons and muscle force/energetics were integrated and in some cases refined to construct the most comprehensive model of the SC + MS to date. The SC + MS’s potential contributions to center-out reaching movement were assessed by employing an extremely simple model of the brain that issued only step commands. Main results. The SC + MS was able to generate physiological muscle dynamics underlying reaching across different directions, distances, speeds, and even in the midst of strong dynamic perturbations (i.e. viscous curl field). For each task, there were many different combinations of brain inputs that generated physiological performance. Natural patterns of recruitment and low metabolic cost emerged for about half of the learning trials when a purely kinematic cost function was used and for all of the trials when an estimate of metabolic energy consumption was added to the cost function. Solutions for different tasks could be interpolated to generate intermediate movement and the range over which interpolation was successful was consistent with experimental reports. Significance. This is the first demonstration that a realistic model of the SC + MS is capable of generating the required dynamics of center-out reaching. The interpolability observed is important for the feasibility of storing motor programs in memory rather than computing them from internal models of the musculoskeletal plant. Successful interpolation of command programs required them to have similar muscle recruitment patterns, which are thought by many to arise from hard-wired muscle synergies rather than learned as in our model system. These properties of the SC + MS along with its tendency to generate

  5. Low-Voltage, Low-Power, and Wide-Tuning-Range Ring-VCO for Frequency ΔΣ Modulator

    DEFF Research Database (Denmark)

    Tuan Vu, Cao; Wisland, Dag T.; Lande, Tor Sverre

    A low-voltage, low-power, and wide-tuning-range VCO which converts an analog input voltage to phase information for a frequency ΔΣ modulator is proposed in this paper. The VCO is based on a differential ring oscillator, which is improved with modified symmetric load and a positive feedback...

  6. Note: A high dynamic range, linear response transimpedance amplifier.

    Science.gov (United States)

    Eckel, S; Sushkov, A O; Lamoreaux, S K

    2012-02-01

    We have built a high dynamic range (nine decade) transimpedance amplifier with a linear response. The amplifier uses junction-gate field effect transistors (JFETs) to switch between three different resistors in the feedback of a low input bias current operational amplifier. This allows for the creation of multiple outputs, each with a linear response and a different transimpedance gain. The overall bandwidth of the transimpedance amplifier is set by the bandwidth of the most sensitive range. For our application, we demonstrate a three-stage amplifier with transimpedance gains of approximately 10(9)Ω, 3 × 10(7)Ω, and 10(4)Ω with a bandwidth of 100 Hz.

  7. Dynamic Contrast Enhanced Magnetic Resonance Imaging of Diffuse Spinal Bone Marrow Infiltration in Patients with Hematological Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Yunfei; Li, Maojin [Renmin Hospital of Wuhan University, Wuhan (China); Yang, Jianyong [the First Affiliated Hospital, Sun Yat-Sen University, Guangzhou (China)

    2010-04-15

    To investigate the significance of the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) parameters of diffuse spinal bone marrow infiltration in patients with hematological malignancies. Dynamic gadolinium-enhanced MR imaging of the lumbar spine was performed in 26 patients with histologically proven diffuse bone marrow infiltration, including multiple myeloma (n = 6), acute lymphoblastic leukemia (n = 6), acute myeloid leukemia (n = 5), chronic myeloid leukemia (n = 7), and non-Hodgkin lymphoma (n = 2). Twenty subjects whose spinal MRI was normal, made up the control group. Peak enhancement percentage (E{sub max}), enhancement slope (ES), and time to peak (TTP) were determined from a time intensity curve (TIC) of lumbar vertebral bone marrow. A comparison between baseline and follow-up MR images and its histological correlation were evaluated in 10 patients. The infiltration grade of hematopoietic marrow with plasma cells was evaluated by a histological assessment of bone marrow. Differences in E{sub max}, ES, and TTP values between the control group and the patients with diffuse bone marrow infiltration were significant (t = -11.51, -9.81 and 3.91, respectively, p < 0.01). E{sub max}, ES, and TTP values were significantly different between bone marrow infiltration groups Grade 1 and Grade 2 (Z = -2.72, -2.24 and -2.89 respectively, p < 0.05). E{sub max}, ES and TTP values were not significantly different between bone marrow infiltration groups Grade 2 and Grade 3 (Z = -1.57, -1.82 and -1.58 respectively, p > 0.05). A positive correlation was found between E{sub max}, ES values and the histological grade of bone marrow infiltration (r = 0.86 and 0.84 respectively, p < 0.01). A negative correlation was found between the TTP values and bone marrow infiltration histological grade (r = -0.54, p < 0.01). A decrease in the E{sub max} and ES values was observed with increased TTP values after treatment in all of the 10 patients who responded to treatment (t

  8. Re-irradiation of the human spinal cord

    Energy Technology Data Exchange (ETDEWEB)

    Sminia, P [VU University Medical Center, Amsterdam (Netherlands); Academic Medical Center, Amsterdam (Netherlands); Oldenburger, F; Hulshof, M C.C.M. [Academic Medical Center, Amsterdam (Netherlands); Slotman, B J [VU University Medical Center, Amsterdam (Netherlands); Schneider, J J [Academic Medical Center, Amsterdam (Netherlands); Netherlands Cancer Inst./Antoni van Leeuwenhoek Hospital, Amsterdam (Germany)

    2002-08-01

    Purpose: Experimental animal data give evidence of long-term recovery of the spinal cord after irradiation. By extrapolation of these data, re-irradiation regimes were designed for eight patients who required palliative radiotherapy. As a consequence of reirradiation, their spinal cords were exposed to cumulative doses exceeding the tolerance dose. Radiobiological and clinical data are presented. Patients and method: Eight patients were re-irradiated on the cervical (n=1), thoracic (n=5) and lumbar (n=2) spinal cord. The time interval between the initial and re-treatment ranged from 4 months to 12.7 years (median: 2.5 years). (Re-)treatment schemes were designed and analyzed on basis of the biologically effective dose (BED) according to the linear-quadratic model. The repair capacity ({alpha}/{beta} ratio) for the cervico-thoracic and lumbar spinal cord was assumed to be 2 Gy and 4 Gy, with a BED{sub tolerance} of 100 Gy and 84 Gy, respectively. Results: The cumulative irradiation dose applied to the spinal cord varied between 125 and 172% of the BED{sub tolerance}. During follow-up, ranging from 33 days to >4.5 years (median: 370 days) none of the patients developed neurological complications. Seven patients died from tumor progression, and one patient is still alive. Conclusion: Long-term recovery of the spinal cord from radiation injury, which has been demonstrated in rodents and primates, may also occur in humans. (orig.) [German] Gegenstand: Tierversuchsdaten belegen eine Langzeiterholung des Rueckenmarks nach Bestrahlung. Nach Extrapolation dieser Daten wurden Wiederbestrahlungsregimes fuer acht Patienten, die eine palliative Radiotherapie benoetigten, entworfen. Als Konsequenz wurde das Rueckenmark dieser Patienten einer kumulativen Dosis ausgesetzt, die die Rueckenmarkstoleranzdosis ueberschritt. Radiobiologische und klinische Daten werden praesentiert. Patienten und Methodik: Bei acht Patienten wurden das zervikale (n=1), thorakale (n=5) und das lumbale (n

  9. Stereo Vision-Based High Dynamic Range Imaging Using Differently-Exposed Image Pair

    Directory of Open Access Journals (Sweden)

    Won-Jae Park

    2017-06-01

    Full Text Available In this paper, a high dynamic range (HDR imaging method based on the stereo vision system is presented. The proposed method uses differently exposed low dynamic range (LDR images captured from a stereo camera. The stereo LDR images are first converted to initial stereo HDR images using the inverse camera response function estimated from the LDR images. However, due to the limited dynamic range of the stereo LDR camera, the radiance values in under/over-exposed regions of the initial main-view (MV HDR image can be lost. To restore these radiance values, the proposed stereo matching and hole-filling algorithms are applied to the stereo HDR images. Specifically, the auxiliary-view (AV HDR image is warped by using the estimated disparity between initial the stereo HDR images and then effective hole-filling is applied to the warped AV HDR image. To reconstruct the final MV HDR, the warped and hole-filled AV HDR image is fused with the initial MV HDR image using the weight map. The experimental results demonstrate objectively and subjectively that the proposed stereo HDR imaging method provides better performance compared to the conventional method.

  10. Spinal cord involvement in tuberculous meningitis.

    Science.gov (United States)

    Garg, R K; Malhotra, H S; Gupta, R

    2015-09-01

    To summarize the incidence and spectrum of spinal cord-related complications in patients of tuberculous meningitis. Reports from multiple countries were included. An extensive review of the literature, published in English, was carried out using Scopus, PubMed and Google Scholar databases. Tuberculous meningitis frequently affects the spinal cord and nerve roots. Initial evidence of spinal cord involvement came from post-mortem examination. Subsequent advancement in neuroimaging like conventional lumbar myelography, computed tomographic myelography and gadolinium-enhanced magnetic resonance-myelography have contributed immensely. Spinal involvement manifests in several forms, like tuberculous radiculomyelitis, spinal tuberculoma, myelitis, syringomyelia, vertebral tuberculosis and very rarely spinal tuberculous abscess. Frequently, tuberculous spinal arachnoiditis develops paradoxically. Infrequently, spinal cord involvement may even be asymptomatic. Spinal cord and spinal nerve involvement is demonstrated by diffuse enhancement of cord parenchyma, nerve roots and meninges on contrast-enhanced magnetic resonance imaging. High cerebrospinal fluid protein content is often a risk factor for arachnoiditis. The most important differential diagnosis of tuberculous arachnoiditis is meningeal carcinomatosis. Anti-tuberculosis therapy is the main stay of treatment for tuberculous meningitis. Higher doses of corticosteroids have been found effective. Surgery should be considered only when pathological confirmation is needed or there is significant spinal cord compression. The outcome in these patients has been unpredictable. Some reports observed excellent recovery and some reported unfavorable outcomes after surgical decompression and debridement. Tuberculous meningitis is frequently associated with disabling spinal cord and radicular complications. Available treatment options are far from satisfactory.

  11. Optogenetics of the Spinal Cord: Use of Channelrhodopsin Proteins for Interrogation of Spinal Cord Circuits.

    Science.gov (United States)

    Rahman, Habibur; Nam, Youngpyo; Kim, Jae-Hong; Lee, Won-Ha; Suk, Kyoungho

    2017-12-29

    Spinal cord circuits play a key role in receiving and transmitting somatosensory information from the body and the brain. They also contribute to the timing and coordination of complex patterns of movement. Under disease conditions, such as spinal cord injury and neuropathic pain, spinal cord circuits receive pain signals from peripheral nerves, and are involved in pain development via neurotransmitters and inflammatory mediators released from neurons and glial cells. Despite the importance of spinal cord circuits in sensory and motor functions, many questions remain regarding the relationship between activation of specific cells and behavioral responses. Optogenetics offers the possibility of understanding the complex cellular activity and mechanisms of spinal cord circuits, as well as having therapeutic potential for addressing spinal cord-related disorders. In this review, we discuss recent findings in optogenetic research employing the channelrhodopsin protein to assess the function of specific neurons and glia in spinal cord circuits ex vivo and in vivo. We also explore the possibilities and challenges of employing optogenetics technology in future therapeutic strategies for the treatment of spinal disorders. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Wavepacket dynamics in one-dimensional system with long-range correlated disorder

    Science.gov (United States)

    Yamada, Hiroaki S.

    2018-03-01

    We numerically investigate dynamical property in the one-dimensional tight-binding model with long-range correlated disorder having power spectrum 1 /fα (α: spectrum exponent) generated by Fourier filtering method. For relatively small α MSD) of the initially localized wavepacket shows ballistic spread and localizes as time elapses. It is shown that α-dependence of the dynamical localization length determined by the MSD exhibits a simple scaling law in the localization regime for the relatively weak disorder strength W. Furthermore, scaled MSD by the dynamical localization length almost obeys an universal function from the ballistic to the localization regime in the various combinations of the parameters α and W.

  13. Spinal Meninges and Their Role in Spinal Cord Injury: A Neuroanatomical Review.

    Science.gov (United States)

    Grassner, Lukas; Grillhösl, Andreas; Griessenauer, Christoph J; Thomé, Claudius; Bühren, Volker; Strowitzki, Martin; Winkler, Peter A

    2018-02-01

    Current recommendations support early surgical decompression and blood pressure augmentation after traumatic spinal cord injury (SCI). Elevated intraspinal pressure (ISP), however, has probably been underestimated in the pathophysiology of SCI. Recent studies provide some evidence that ISP measurements and durotomy may be beneficial for individuals suffering from SCI. Compression of the spinal cord against the meninges in SCI patients causes a "compartment-like" syndrome. In such cases, intentional durotomy with augmentative duroplasty to reduce ISP and improve spinal cord perfusion pressure (SCPP) may be indicated. Prior to performing these procedures routinely, profound knowledge of the spinal meninges is essential. Here, we provide an in-depth review of relevant literature along with neuroanatomical illustrations and imaging correlates.

  14. MR imaging and spinal cord injury

    International Nuclear Information System (INIS)

    Azar-Kia, B.; Fine, M.; Naheedy, M.; Elias, D.

    1987-01-01

    MR imaging has significantly improved diagnostic capability of spinal cord injuries. Other available diagnostic modalities such as plain films, myelography, CT, and post-CT myelography have failed to consistently show the secific evidence of spinal cord injuries and their true extent. The authors are presenting our experiences with MR imaging in spinal column injury. They have found MR imaging to be the procedure of choice for prognostic evaluation of spinal cord trauma. They are showing examples of recent and old spinal cord injury such as hematomyelia, myelomalacia, transection, spinal cord edema, and cavitation

  15. Trans-spinal direct current stimulation for the modulation of the lumbar spinal motor networks

    NARCIS (Netherlands)

    Kuck, Alexander

    2018-01-01

    Trans-spinal Direct Current Stimulation (tsDCS) is a noninvasive neuromodulatory tool for the modulation of the spinal neurocircuitry. Initial studies have shown that tsDCS is able to induce a significant and lasting change in spinal-reflex- and corticospinal information processing. It is therefore

  16. Sorting method to extend the dynamic range of the Shack-Hartmann wave-front sensor

    International Nuclear Information System (INIS)

    Lee, Junwon; Shack, Roland V.; Descour, Michael R.

    2005-01-01

    We propose a simple and powerful algorithm to extend the dynamic range of a Shack-Hartmann wave-front sensor. In a conventional Shack-Hartmann wave-front sensor the dynamic range is limited by the f-number of a lenslet, because the focal spot is required to remain in the area confined by the single lenslet. The sorting method proposed here eliminates such a limitation and extends the dynamic range by tagging each spot in a special sequence. Since the sorting method is a simple algorithm that does not change the measurement configuration, there is no requirement for extra hardware, multiple measurements, or complicated algorithms. We not only present the theory and a calculation example of the sorting method but also actually implement measurement of a highly aberrated wave front from nonrotational symmetric optics

  17. A Comprehensive Analysis of the SRS-Schwab Adult Spinal Deformity Classification and Confounding Variables

    DEFF Research Database (Denmark)

    Hallager, Dennis Winge; Hansen, Lars Valentin; Dragsted, Casper Rokkjær

    2016-01-01

    STUDY DESIGN: Cross-sectional analyses on a consecutive, prospective cohort. OBJECTIVE: To evaluate the ability of the Scoliosis Research Society (SRS)-Schwab Adult Spinal Deformity Classification to group patients by widely used health-related quality-of-life (HRQOL) scores and examine possible...... to confounding. However, age group and aetiology had individual significant effects. CONCLUSION: The SRS-Schwab sagittal modifiers reliably grouped patients graded 0 versus + / +  + according to the most widely used HRQOL scores and the effects of increasing grade level on odds for worse ODI scores remained...... confounding variables. SUMMARY OF BACKGROUND DATA: The SRS-Schwab Adult Spinal Deformity Classification includes sagittal modifiers considered important for HRQOL and the clinical impact of the classification has been validated in patients from the International Spine Study Group database; however, equivocal...

  18. Association of decision-making in spinal surgery with specialty and emotional involvement-the Indications in Spinal Surgery (INDIANA) survey.

    Science.gov (United States)

    Sollmann, Nico; Morandell, Carmen; Albers, Lucia; Behr, Michael; Preuss, Alexander; Dinkel, Andreas; Meyer, Bernhard; Krieg, Sandro M

    2018-03-01

    Although recent trials provided level I evidence for the most common degenerative lumbar spinal disorders, treatment still varies widely. Thus, the Indications in Spinal Surgery (INDIANA) survey explores whether decision-making is influenced by specialty or personal emotional involvement of the treating specialist. Nationwide, neurosurgeons and orthopedic surgeons specialized in spine surgery were asked to answer an Internet-based questionnaire with typical clinical patient cases of lumbar disc herniation (DH), lumbar spinal stenosis (SS), and lumbar degenerative spondylolisthesis (SL). The surgeons were assigned to counsel a patient or a close relative, thus creating emotional involvement. This was achieved by randomly allocating the surgeons to a patient group (PG) and relative group (RG). We then compared neurosurgeons to orthopedic surgeons and the PG to the RG regarding treatment decision-making. One hundred twenty-two spine surgeons completed the questionnaire (response rate 78.7%). Regarding DH and SS, more conservative treatment among orthopedic surgeons was shown (DH: odds ratio [OR] 4.1, 95% confidence interval [CI] 1.7-9.7, p = 0.001; SS: OR 3.9, CI 1.8-8.2, p emotional involvement (PG vs. RG) did not affect these results for any of the three cases (DH: p = 0.213; SS: p = 0.097; SL: p = 0.924). The high response rate indicates how important the issues raised by this study actually are for dedicated spine surgeons. Moreover, there are considerable variations in decision-making for the most common degenerative lumbar spinal disorders, although there is high-quality data from large multicenter trials available. Emotional involvement, though, did not influence treatment recommendations.

  19. Anterior spinal cord syndrome of unknown etiology

    OpenAIRE

    Klakeel, Merrine; Thompson, Justin; Srinivasan, Rajashree; McDonald, Frank

    2015-01-01

    A spinal cord injury encompasses a physical insult to the spinal cord. In the case of anterior spinal cord syndrome, the insult is a vascular lesion at the anterior spinal artery. We present the cases of two 13-year-old boys with anterior spinal cord syndrome, along with a review of the anatomy and vasculature of the spinal cord and an explanation of how a lesion in the cord corresponds to anterior spinal cord syndrome.

  20. Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache

    Science.gov (United States)

    Xu, Hong; Liu, Yang; Song, WenYe; Kan, ShunLi; Liu, FeiFei; Zhang, Di; Ning, GuangZhi; Feng, ShiQing

    2017-01-01

    Abstract Background: Postdural puncture headache (PDPH), mainly resulting from the loss of cerebral spinal fluid (CSF), is a well-known iatrogenic complication of spinal anesthesia and diagnostic lumbar puncture. Spinal needles have been modified to minimize complications. Modifiable risk factors of PDPH mainly included needle size and needle shape. However, whether the incidence of PDPH is significantly different between cutting-point and pencil-point needles was controversial. Then we did a meta-analysis to assess the incidence of PDPH of cutting spinal needle and pencil-point spinal needle. Methods: We included all randomly designed trials, assessing the clinical outcomes in patients given elective spinal anesthesia or diagnostic lumbar puncture with either cutting or pencil-point spinal needle as eligible studies. All selected studies and the risk of bias of them were assessed by 2 investigators. Clinical outcomes including success rates, frequency of PDPH, reported severe PDPH, and the use of epidural blood patch (EBP) were recorded as primary results. Results were evaluated using risk ratio (RR) with 95% confidence interval (CI) for dichotomous variables. Rev Man software (version 5.3) was used to analyze all appropriate data. Results: Twenty-five randomized controlled trials (RCTs) were included in our study. The analysis result revealed that pencil-point spinal needle would result in lower rate of PDPH (RR 2.50; 95% CI [1.96, 3.19]; P < 0.00001) and severe PDPH (RR 3.27; 95% CI [2.15, 4.96]; P < 0.00001). Furthermore, EBP was less used in pencil-point spine needle group (RR 3.69; 95% CI [1.96, 6.95]; P < 0.0001). Conclusions: Current evidences suggest that pencil-point spinal needle was significantly superior compared with cutting spinal needle regarding the frequency of PDPH, PDPH severity, and the use of EBP. In view of this, we recommend the use of pencil-point spinal needle in spinal anesthesia and lumbar puncture. PMID:28383416