WorldWideScience

Sample records for spii hip system

  1. Hip Implant Systems

    Science.gov (United States)

    ... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...

  2. Hip Inflammation MRI Scoring System (HIMRISS) to predict response to hyaluronic acid injection in hip osteoarthritis

    DEFF Research Database (Denmark)

    Deseyne, Nicolas; Conrozier, Thierry; Lellouche, Henri

    2018-01-01

    OBJECTIVE: To assess predictors of response, according to hip MRI inflammatory scoring system (HIMRISS), in a sample of patients with hip osteoarthritis (OA) treated by hyaluronic acid (HA) injection. METHOD: Sixty patients with hip OA were included. Clinical outcomes were assessed at baseline...... SP=0.97, sensitivity SN=0.39, and positive and negative predictive values of 0.91 and 0.64, respectively. CONCLUSION: HIMRISS is reliable for total scores and sub-domains. It permits identification of responders to HA injection in hip OA patients........64, 0.83 and 0.78. Associations between MRI features and clinical data were assessed. Logistic regression (univariate and multivariate) was used to explore associations between MRI features and response to HA injection, according to WOMAC50 response at three months. RESULTS: In total, 45.5% of patients...

  3. Hip resurfacing in a district general hospital: 6-year clinical results using the ReCap hip resurfacing system

    Directory of Open Access Journals (Sweden)

    van der Weegen Walter

    2012-12-01

    Full Text Available Abstract Background The purpose of our study was to prospectively report the clinical results of 280 consecutive hips (240 patients who received a ReCap Hip Resurfacing System implant (Biomet Inc., Warsaw, USA in a single district general hospital. Literature reports a large variation in clinical results between different resurfacing designs and published results using this particular design are scarce. Methods Mean follow up was 3.3 years (1.0 to 6.3 and four patients were lost to follow-up. All patients were diagnosed with end-stage hip osteoarthritis, their mean age was 54 years and 76.4% of all patients were male. Results There were 16 revisions and four patients reported a Harris Hip Score Conclusions This independent series confirms that hip resurfacing is a demanding procedure, and that implant survival of the ReCap hip resurfacing system is on a critical level in our series. In non-revised patients, reported outcomes are generally excellent. Trial registration ClinicalTrials.gov Identifier: NCT00603395

  4. Effect of component design in retrieved bipolar hip hemiarthroplasty systems.

    Science.gov (United States)

    Hess, Matthew D; Baker, Erin A; Salisbury, Meagan R; Kaplan, Lige M; Greene, Ryan T; Greene, Perry W

    2013-09-01

    Primary articulation of bipolar hemiarthroplasty systems is at the femoral head-liner interface. The purpose of this study was to compare observed damage modes on 36 retrieved bipolar systems with implant, demographic, intraoperative, and radiographic data to elucidate the effects of component design, specifically locking mechanism, on clinical performance. Retrieved bipolar hip hemiarthroplasty systems of 3 different design types were obtained, disassembled, and evaluated macro- and microscopically for varying modes of wear, including abrasion, burnishing, embedding, scratching, and pitting. Clinical record review and radiographic analysis were performed by a senior orthopedic surgery resident. Average bipolar hip hemiarthroplasty system term of service was 46 months (range, 0.27-187 months). All devices contained wear debris captured within the articulating space between the femoral head and liner. In 31% of patients without infection, lucency was observed on immediate prerevision radiographs. The system with a leaf locking mechanism showed significantly increased radiographically observed osteolysis (P=.03) compared with a system with a stopper ring locking mechanism. In addition, implant design and observed damage modes, including pitting and third-body particle embedding, were significantly associated with radiographically observed osteolysis. Copyright 2013, SLACK Incorporated.

  5. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    OpenAIRE

    Hirokazu Takai, MD; Tomoki Takahashi, MD, PhD

    2017-01-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used ...

  6. Validation of a standardized mapping system of the hip joint for radial MRA sequencing

    International Nuclear Information System (INIS)

    Klenke, Frank M.; Hoffmann, Daniel B.; Cross, Brian J.; Siebenrock, Klaus A.

    2015-01-01

    Intraarticular gadolinium-enhanced magnetic resonance arthrography (MRA) is commonly applied to characterize morphological disorders of the hip. However, the reproducibility of retrieving anatomic landmarks on MRA scans and their correlation with intraarticular pathologies is unknown. A precise mapping system for the exact localization of hip pathomorphologies with radial MRA sequences is lacking. Therefore, the purpose of the study was the establishment and validation of a reproducible mapping system for radial sequences of hip MRA. Sixty-nine consecutive intraarticular gadolinium-enhanced hip MRAs were evaluated. Radial sequencing consisted of 14 cuts orientated along the axis of the femoral neck. Three orthopedic surgeons read the radial sequences independently. Each MRI was read twice with a minimum interval of 7 days from the first reading. The intra- and inter-observer reliability of the mapping procedure was determined. A clockwise system for hip MRA was established. The teardrop figure served to determine the 6 o'clock position of the acetabulum; the center of the greater trochanter served to determine the 12 o'clock position of the femoral head-neck junction. The intra- and inter-observer ICCs to retrieve the correct 6/12 o'clock positions were 0.906-0.996 and 0.978-0.988, respectively. The established mapping system for radial sequences of hip joint MRA is reproducible and easy to perform. (orig.)

  7. Actis Total Hip System 2 Year Follow-up

    Science.gov (United States)

    2017-08-14

    Osteoarthritis; Traumatic Arthritis; Rheumatoid Arthritis; Congenital Hip Dysplasia; Avascular Necrosis of the Femoral Head; Acute Traumatic Fracture of the Femoral Head or Neck; Certain Cases of Ankylosis; Non-union of Femoral Neck Fractures; Certain High Sub-Capital & Femoral Neck Fractures in Elderly

  8. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system.

    Science.gov (United States)

    Takai, Hirokazu; Takahashi, Tomoki

    2017-09-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  9. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system

    Directory of Open Access Journals (Sweden)

    Hirokazu Takai, MD

    2017-09-01

    Full Text Available Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  10. Compact Hip-Force Sensor for a Gait-Assistance Exoskeleton System.

    Science.gov (United States)

    Choi, Hyundo; Seo, Keehong; Hyung, Seungyong; Shim, Youngbo; Lim, Soo-Chul

    2018-02-13

    In this paper, we propose a compact force sensor system for a hip-mounted exoskeleton for seniors with difficulties in walking due to muscle weakness. It senses and monitors the delivered force and power of the exoskeleton for motion control and taking urgent safety action. Two FSR (force-sensitive resistors) sensors are used to measure the assistance force when the user is walking. The sensor system directly measures the interaction force between the exoskeleton and the lower limb of the user instead of a previously reported force-sensing method, which estimated the hip assistance force from the current of the motor and lookup tables. Furthermore, the sensor system has the advantage of generating torque in the walking-assistant actuator based on directly measuring the hip-assistance force. Thus, the gait-assistance exoskeleton system can control the delivered power and torque to the user. The force sensing structure is designed to decouple the force caused by hip motion from other directional forces to the sensor so as to only measure that force. We confirmed that the hip-assistance force could be measured with the proposed prototype compact force sensor attached to a thigh frame through an experiment with a real system.

  11. Compact Hip-Force Sensor for a Gait-Assistance Exoskeleton System

    Directory of Open Access Journals (Sweden)

    Hyundo Choi

    2018-02-01

    Full Text Available In this paper, we propose a compact force sensor system for a hip-mounted exoskeleton for seniors with difficulties in walking due to muscle weakness. It senses and monitors the delivered force and power of the exoskeleton for motion control and taking urgent safety action. Two FSR (force-sensitive resistors sensors are used to measure the assistance force when the user is walking. The sensor system directly measures the interaction force between the exoskeleton and the lower limb of the user instead of a previously reported force-sensing method, which estimated the hip assistance force from the current of the motor and lookup tables. Furthermore, the sensor system has the advantage of generating torque in the walking-assistant actuator based on directly measuring the hip-assistance force. Thus, the gait-assistance exoskeleton system can control the delivered power and torque to the user. The force sensing structure is designed to decouple the force caused by hip motion from other directional forces to the sensor so as to only measure that force. We confirmed that the hip-assistance force could be measured with the proposed prototype compact force sensor attached to a thigh frame through an experiment with a real system.

  12. Outcome of total hip arthroplasty for avascular necrosis of the femoral head in systemic lupus erythematosus.

    Science.gov (United States)

    Woo, Min Su; Kang, Joon Soon; Moon, Kyoung Ho

    2014-12-01

    This study evaluated the result of total hip arthroplasty (THA) for avascular necrosis of the femur head (AVNFH) in systemic lupus erythematosus (SLE) patients. Nineteen THAs were performed on 13 patients with SLE. The results of these patients were compared with the results of the control group (19 patients) who had THR due to AVNFH with none-SLE conditions. The Harris hip score increased from a preoperative average of 65.3 points to 94.9 at the most recent follow-up. In the control group, the mean HHS was 67.2 preoperatively and 96.1 postoperatively at the last follow-up. No significant difference was found between SLE patients and non-SLE patients who underwent hip arthroplasty. In conclusion, THA is an acceptable treatment for achieving functional improvement in patients who had SLE and AVNFH. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Automatic measurement system for congenital hip dislocation using a computed radiography

    International Nuclear Information System (INIS)

    Komori, M.; Minato, K.; Hirakawa, A.; Kuwahara, M.

    1988-01-01

    Acetabular angle which is a diagnostic parameter of congenital hip dislocation has been measured manually in conventional X-ray film system. Using digital image directly provided from a computed radiography, an automatic measurement system was developed for this parameter. The process of the measurement was completed within a reasonable time, and accurate enough. The system was combined with an image database, so that it would be a measurement tool of PACS

  14. TREATMENT OF HIP DYSPLASIA

    OpenAIRE

    Iulian ICLEANU; Mariana CORDUN

    2015-01-01

    In this thesis, our purpose is to show that using physiotherapy on patients with hip dysplasia from the very beginning, in the first months of life, helps treating them faster. Common literature proposes to use physiotherapy on patients with hip dysplasia either after their recovery or in the terminal phase of recovery, claiming that any earlier intervention will prolong the hip recovery. The effects of hip dysplasia reflect over the whole musculoskeletal system, while it hinders the knees (g...

  15. Hip, Hip, Soret!

    Science.gov (United States)

    Müller-Plathe, Florian

    Many years ago, Ludwig did detect the behaviour now called the Soret effect. Sodium sulphate in eighteen-fifty-six did not obediently follow Fick's first law. But if he cooled down one side the salt went left, the water to the right. He was surprised in every way. Hip, hip, Soret!

  16. A quantitative assessment of facial protection systems in elective hip arthroplasty.

    Science.gov (United States)

    Hirpara, Kieran Michael; O'Halloran, Emily; O'Sullivan, Michael

    2011-06-01

    We aimed to assess the risk to surgeons of blood splatter during total hip arthroplasty. Hoods from personal protection systems used in 34 consecutive total hip replacements were collected and the area of blood splatter was measured and compared to goggles and visors. Thirty one primary THA's (13 cemented, 4 hybrid, 14 uncemented) and 3 revisions (1 hybrid, 2 uncemented) were collected. Splashes were detected on all of the masks with a mean of 034% cover. Splatter was greatest for the operating surgeon, followed by the first assistant, though the difference was not statistically significant. Operating personnel were at greater risk of contamination during uncemented arthroplasty (p blood cover was outside the area protected by goggles and visors respectively. There was a significant difference between the Personal Protection Systems (PPS) and goggles (p = 0.0231; 95% CI) as well as between the PPS and visors (p = 0.0293; 95% CI).

  17. Rapidly destructive arthrosis of the hip joint in a young adult with systemic lupus erythematosus.

    Science.gov (United States)

    Lee, Yongseung; Motomura, Goro; Yamamoto, Takuaki; Nakashima, Yasuharu; Ohishi, Masanobu; Hamai, Satoshi; Iura, Kunio; Iwamoto, Yukihide

    2015-10-01

    A 37-year-old female had been treated with corticosteroids for systemic lupus erythematosus clinically diagnosed at age 10. She suddenly had right hip pain without any antecedent trauma. Four months after the onset of pain, she visited her primary care physician. On magnetic resonance imaging, joint space narrowing at the weight-bearing area was already seen with bone marrow edematous lesions in both the femoral head and acetabulum. She was treated non-operatively; however, her pain continued to worsen in severity. Thirteen months after the onset of pain, she was referred to our hospital. A plain radiograph showed subluxation of the collapsed femoral head accompanied by destruction of the acetabular rim. Because of her severe intractable pain, she underwent total hip arthroplasty 1 month after her first visit. Histological examination of the resected femoral head revealed pseudogranulomatous lesions along with prominent callus formation, suggesting rapid destruction of the femoral head.

  18. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    Science.gov (United States)

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  19. A Medical Wireless Measurement System for Hip Prosthesis Loosening Detection Based on Vibration Analysis

    Directory of Open Access Journals (Sweden)

    Sebastian Sauer

    2013-01-01

    Full Text Available Vibration analysis is a promising approach in order to detect early hip prosthesis loosening, with the potential to extend the range of diagnostic tools currently available in clinical routine. Ongoing research efforts and developments in the area of multi-functional implants, which integrate sensors, wireless power supply, communication and signal processing, provide means to obtain valuable in vivo information otherwise not available. In the current work a medical wireless measurement system is presented, which is integrated in the femoral head of a hip prosthesis. The passive miniaturized system includes a 3-axis acceleration sensor and signal pre-processing based on a lock-in amplifier circuit. Bidirectional data communication and power supply is reached through inductive coupling with an operating frequency of 125 kHz in accordance with the ISO 18000-2 protocol standard. The system allows the acquisition of the acceleration frequency response of the femur-prosthesis system between 500 to 2500 Hz. Applied laboratory measurements with system prototypes on artificial bones and integrated prostheses demonstrate the feasibility of the measurement system approach, clearly showing differences in the vibration behavior due to an implant loosening. In addition a possibility to evaluate the non-linear mechanic system behavior is presented.

  20. Verification of the Robin and Graham classification system of hip disease in cerebral palsy using three-dimensional computed tomography.

    Science.gov (United States)

    Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Akiyama, Keisuke; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2011-12-01

    We evaluated the validity of the Robin and Graham classification system of hip disease in cerebral palsy (CP) using three-dimensional computed tomography in young people with CP. A total of 91 hips in 91 consecutive children with bilateral spastic CP (57 males, 34 females; nine classified at Gross Motor Function Classification System level II, 42 at level III, 32 at level IV, and eight at level V; mean age 5 y 2 mo, SD 11 mo; range 2-6 y) were investigated retrospectively using anteroposterior plain radiographs and three-dimensional computed tomography (3D-CT) of the hip. The migration percentage was calculated on plain radiographs and all participants were classified into four groups according to migration percentage: grade II, migration percentage ≥ 10% but ≤ 15%, (four hips), grade III, migration percentage >15% but ≤ 30%, (20 hips); grade IV, migration percentage >30% but <100%, (63 hips); and grade V, migration percentage ≥ 100%, (four hips). The lateral opening angle and the sagittal inclination angle of the acetabulum, the neck-shaft angle, and the femoral anteversion of the femur were measured on 3D-CT. The three-dimensional quantitative evaluation indicated that there were significant differences in the lateral opening angle and the neck-shaft angle between the four groups (Kruskal-Wallis test, p ≤ 0.001). This three-dimensional evaluation supports the validation of the Robin and Graham classification system for hip disease in 2- to 7-year-olds with CP. © The Authors. Developmental Medicine & Child Neurology © 2011 Mac Keith Press.

  1. Three cases of systemic amyloidosis successfully diagnosed by subcutaneous fat tissue biopsy of the hip

    Directory of Open Access Journals (Sweden)

    Arahata M

    2016-08-01

    Full Text Available Masahisa Arahata,1 Shigeru Shimadoi,1 Satosi Yamatani,1 Shin-ichi Hayashi,2 Shigeharu Miwa,2 Hidesaku Asakura,3 Shinji Nakao4 1Department of Internal Medicine, Nanto Municipal Hospital, Nanto, 2Department of Diagnostic Pathology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, 3Department of Internal Medicine (III, 4Department of Cellular Transplantation Biology, Division of Cancer Medicine, Graduate School of Medical Science, Kanazawa University, Kanazawa, Japan Abstract: Fine-needle aspiration biopsy of the abdominal fat pad is considered to be a minimally invasive procedure for diagnosing systemic amyloidosis. However, this procedure is sometimes difficult and can be dangerous for elderly patients whose abdominal fat layer is thin because of malnutrition. In such cases, alternative diagnostic methods are required. We report three elderly patients with heart failure complicated by malnutrition. In all cases, electrocardiogram showed low voltage in the limb leads and a pseudoinfarct pattern in the chest leads, and echocardiography showed left ventricular wall thickening with granular sparkling appearance. These patients were suspected of having amyloid cardiomyopathy but could not undergo myocardial biopsies because of their poor conditions. After failed attempts at biopsy of the abdominal fat pad or the other organs, subcutaneous fat tissue biopsy over the hip led to the diagnosis of systemic amyloidosis with cardiomyopathy. The resultant diagnosis guided us to choose the appropriate treatment for the patients. This article illustrates that subcutaneous fat tissue biopsy of the hip could be a useful procedure for diagnosing systemic amyloidosis in elderly patients, particularly when a fat tissue biopsy of the abdomen is associated with a high risk of complications because of malnutrition. Keywords: systemic amyloidosis, amyloid cardiomyopathy, fine-needle aspiration biopsy, subcutaneous fat tissue, hip

  2. Hip Fracture

    Science.gov (United States)

    ... hip fractures in people of all ages. In older adults, a hip fracture is most often a result of a fall from a standing height. In people with very weak bones, a hip fracture can occur simply by standing on the leg and twisting. Risk factors The rate of hip fractures increases substantially with ...

  3. M2K. II. A TRIPLE-PLANET SYSTEM ORBITING HIP 57274

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Debra A.; Giguere, Matthew J.; Moriarty, John; Brewer, John; Spronck, Julien F. P.; Schwab, Christian; Szymkowiak, Andrew [Department of Astronomy, Yale University, New Haven, CT 06511 (United States); Gaidos, Eric [Department of Geology and Geophysics, University of Hawaii, Honolulu, HI 96822 (United States); Howard, Andrew W.; Marcy, Geoffrey W. [Department of Astronomy, University of California at Berkeley, Berkeley, CA 94720 (United States); Johnson, John A. [Department of Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Wright, Jason T. [Center for Exoplanets and Habitable Worlds, 525 Davey Lab, The Pennsylvania State University, University Park, PA 16803 (United States); Valenti, Jeff A. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Piskunov, Nikolai [Department of Astronomy and Space Physics, Uppsala University, Box 515, 751 20 Uppsala (Sweden); Clubb, Kelsey I.; Isaacson, Howard [Pufendorf Institute for Advanced Studies, Lund University, Lund (Sweden); Apps, Kevin [75B Cheyne Walk, Surrey RH6 7LR (United Kingdom); Lepine, Sebastien [American Museum of Natural History, New York, NY 10023 (United States); Mann, Andrew, E-mail: debra.fischer@yale.edu [Institute for Astronomy, University of Hawaii, Honolulu, HI 96822 (United States)

    2012-01-20

    Doppler observations from Keck Observatory have revealed a triple-planet system orbiting the nearby K4V star, HIP 57274. The inner planet, HIP 57274b, is a super-Earth with Msin i = 11.6 M{sub Circled-Plus} (0.036 M{sub Jup}), an orbital period of 8.135 {+-} 0.004 days, and slightly eccentric orbit e = 0.19 {+-} 0.1. We calculate a transit probability of 6.5% for the inner planet. The second planet has Msin i = 0.4 M{sub Jup} with an orbital period of 32.0 {+-} 0.02 days in a nearly circular orbit (e = 0.05 {+-} 0.03). The third planet has Msin i = 0.53 M{sub Jup} with an orbital period of 432 {+-} 8 days (1.18 years) and an eccentricity e = 0.23 {+-} 0.03. This discovery adds to the number of super-Earth mass planets with M sin i < 12 M{sub Circled-Plus} that have been detected with Doppler surveys. We find that 56% {+-} 18% of super-Earths are members of multi-planet systems. This is certainly a lower limit because of observational detectability limits, yet significantly higher than the fraction of Jupiter mass exoplanets, 20% {+-} 8%, that are members of Doppler-detected, multi-planet systems.

  4. M2K. II. A TRIPLE-PLANET SYSTEM ORBITING HIP 57274

    International Nuclear Information System (INIS)

    Fischer, Debra A.; Giguere, Matthew J.; Moriarty, John; Brewer, John; Spronck, Julien F. P.; Schwab, Christian; Szymkowiak, Andrew; Gaidos, Eric; Howard, Andrew W.; Marcy, Geoffrey W.; Johnson, John A.; Wright, Jason T.; Valenti, Jeff A.; Piskunov, Nikolai; Clubb, Kelsey I.; Isaacson, Howard; Apps, Kevin; Lepine, Sebastien; Mann, Andrew

    2012-01-01

    Doppler observations from Keck Observatory have revealed a triple-planet system orbiting the nearby K4V star, HIP 57274. The inner planet, HIP 57274b, is a super-Earth with Msin i = 11.6 M ⊕ (0.036 M Jup ), an orbital period of 8.135 ± 0.004 days, and slightly eccentric orbit e = 0.19 ± 0.1. We calculate a transit probability of 6.5% for the inner planet. The second planet has Msin i = 0.4 M Jup with an orbital period of 32.0 ± 0.02 days in a nearly circular orbit (e = 0.05 ± 0.03). The third planet has Msin i = 0.53 M Jup with an orbital period of 432 ± 8 days (1.18 years) and an eccentricity e = 0.23 ± 0.03. This discovery adds to the number of super-Earth mass planets with M sin i ⊕ that have been detected with Doppler surveys. We find that 56% ± 18% of super-Earths are members of multi-planet systems. This is certainly a lower limit because of observational detectability limits, yet significantly higher than the fraction of Jupiter mass exoplanets, 20% ± 8%, that are members of Doppler-detected, multi-planet systems.

  5. Isolated hip fracture care in an inclusive trauma system : A trauma system wide evaluation

    NARCIS (Netherlands)

    van Laarhoven, J. J E M; van Lammeren, G. W.; Houwert, R. M.; van Laarhoven, Constance; Hietbrink, F.; Leenen, L. P H; Verleisdonk, E. J M M

    2015-01-01

    Introduction: Elderly patients with a hip fracture represent a large proportion of the trauma population; however, little is known about outcome differences between different levels of trauma care for these patients. The aim of this study is to analyse the outcome of trauma care in patients with a

  6. Stem Migration and Fretting Corrosion of the Antirotation Pin in the K2/Apex Hip System.

    Science.gov (United States)

    Kent, Michael; Edmondson, Mark; Ebert, Jay; Nivbrant, Nils; Kop, Alan; Wood, David; De Steiger, Richard

    2016-03-01

    Many exchangeable neck hip systems have been withdrawn because of fretting corrosion at the neck/stem coupling. Our prospective randomized study evaluating stem stability (Roentgen stereophotogrammetric analysis, dual-energy x-ray absorptiometry) and clinical outcomes between the K2/Apex hip systems was ceased early because of a withdrawal of the stems which had an unfavorably high early revision rate reported in the Australian Orthopaedic Association National Joint Registry (9.3% at 3 years). At 2 years, there are no clinical differences between the stems. Roentgen stereophotogrammetric analysis has identified a high proportion of potentially concerning subsidence and retroversion in both groups, more marked in the K2 stem, although mostly in asymptomatic patients. Dual-energy x-ray absorptiometry has shown similar bone density around the stems. Retrieval analysis of 3 study patients showed fretting corrosion of the antirotation pin and aseptic lymphocyte-dominated vasculitis-associated lesion, with no relationship to bearing type or size. Analysis of 7 further nonstudy K2/Apex stems confirmed similar corrosion. This study shows potentially concerning subsidence of both stems and is the first to describe corrosion at the neck-stem interface and a relationship to metal-related pathology. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  7. A quantitative assessment of facial protection systems in elective hip arthroplasty.

    LENUS (Irish Health Repository)

    Hirpara, Kieran Michael

    2011-06-01

    We aimed to assess the risk to surgeons of blood splatter during total hip arthroplasty. Hoods from personal protection systems used in 34 consecutive total hip replacements were collected and the area of blood splatter was measured and compared to goggles and visors. Thirty one primary THA\\'s (13 cemented, 4 hybrid, 14 uncemented) and 3 revisions (1 hybrid, 2 uncemented) were collected. Splashes were detected on all of the masks with a mean of 034% cover. Splatter was greatest for the operating surgeon, followed by the first assistant, though the difference was not statistically significant. Operating personnel were at greater risk of contamination during uncemented arthroplasty (p < 0.0001; 95% CI). On average 50.60% and 45.40% of blood cover was outside the area protected by goggles and visors respectively. There was a significant difference between the Personal Protection Systems (PPS) and goggles (p = 0.0231; 95% CI) as well as between the PPS and visors (p = 0.0293; 95% CI).

  8. Hip pain

    Science.gov (United States)

    ... from a chair, walking, climbing stairs, and driving Hamstring strain Iliotibial band syndrome Hip flexor strain Hip ... and cool down afterward. Stretch your quadriceps and hamstrings. Avoid running straight down hills. Walk down instead. ...

  9. Hip joint replacement

    Science.gov (United States)

    Hip arthroplasty; Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... Your hip joint is made up of 2 major parts. One or both parts may be replaced during surgery: ...

  10. Post-market Surveillance Study With the HYPERION Hip Endoprosthesis System in Defect Reconstruction

    Science.gov (United States)

    2017-12-19

    Osteoarthritis; Avascular Necrosis; Rheumatoid Arthritis; Functional Deformities; Pseudoarthrosis; Revision of Endoprosthesis-treated Hips; Fracture, Proximal Humeral; Provision of Non-endoprosthetic Previous Operations of the Hip Joint (e.g., Transposition Osteotomies); Femur Fracture; Pseudarthrosis; Trochanteric Fractures; Bridging of Large Bone Defects; Revisions

  11. TREATMENT OF HIP DYSPLASIA

    Directory of Open Access Journals (Sweden)

    Iulian ICLEANU

    2015-11-01

    Full Text Available In this thesis, our purpose is to show that using physiotherapy on patients with hip dysplasia from the very beginning, in the first months of life, helps treating them faster. Common literature proposes to use physiotherapy on patients with hip dysplasia either after their recovery or in the terminal phase of recovery, claiming that any earlier intervention will prolong the hip recovery. The effects of hip dysplasia reflect over the whole musculoskeletal system, while it hinders the knees (genu valgum, the ankles (ankle valgus, calcaneal valgus and the spine (scoliosis especially at the lumbar level. The most spectacular are at the hip level, that is why we made an analytical evaluation only for this joint. To show the importance of physiotherapy for children with hip dysplasia we started from the hypothesis: untimely treatment for children with hip dysplasia has improved results in functional recovery and in obtaining a better stability, without the necessity of orthopedics or surgical interventions. The research methods used in this study are: the observation method, the bibliographic study method, the experimental method, the graphics method and the statistical mathematical method to process the data and to represent the results graphically. In the end, the results obtained are significantly different from the initial evaluations and we came to the conclusion that starting an untimely analytical kinetic treatment and globally personalizing it to every patient improves stability and biomechanical parameters for the hip.

  12. Pigmented villonodular synovitis of the hip in systemic lupus erythematosus: a case report

    Directory of Open Access Journals (Sweden)

    Anders Hans-Joachim

    2011-09-01

    Full Text Available Abstract Introduction Pigmented villonodular synovitis is a rare disease of unknown etiology mostly affecting the knee and foot. Until now an association with autoimmune diseases has not been reported. Case presentation The diagnosis of systemic lupus erythematosus was made in a 15-year-old Caucasian girl based on otherwise unexplained fatigue, arthralgia, tenosynovitis, leukopenia, low platelets and the presence of antinuclear and deoxyribonucleic antibodies. At the age of 20 a renal biopsy revealed lupus nephritis class IV and she went into complete remission with mycophenolate mofetil and steroids. She was kept on mycophenolate mofetil for maintenance therapy. At the age of 24 she experienced a flare-up of lupus nephritis with nephrotic syndrome and new onset of pain in her right hip. Magnetic resonance imaging, arthroscopy and subtotal synovectomy identified pigmented villonodular synovitis as the underlying diagnosis. Although her systemic lupus erythematosus went into remission with another course of steroids and higher doses of mycophenolate mofetil, the pigmented villonodular synovitis persisted and she had to undergo open synovectomy to control her symptoms. Conclusion Systemic lupus erythematosus is associated with many different musculoskeletal manifestations including synovitis and arthritis. Pigmented villonodular synovitis has not previously been reported in association with systemic lupus erythematosus, but as its etiology is still unknown, the present case raises the question about a causal relationship between systemic lupus erythematosus and pigmented villonodular synovitis.

  13. Preliminary validation of 2 magnetic resonance image scoring systems for osteoarthritis of the hip according to the OMERACT filter.

    Science.gov (United States)

    Maksymowych, Walter P; Cibere, Jolanda; Loeuille, Damien; Weber, Ulrich; Zubler, Veronika; Roemer, Frank W; Jaremko, Jacob L; Sayre, Eric C; Lambert, Robert G W

    2014-02-01

    Development of a validated magnetic resonance image (MRI) scoring system is essential in hip OA because radiographs are insensitive to change. We assessed the feasibility and reliability of 2 previously developed scoring methods: (1) the Hip Inflammation MRI Scoring System (HIMRISS) and (2) the Hip Osteoarthritis MRI Scoring System (HOAMS). Six readers (3 radiologists, 3 rheumatologists) participated in 2 reading exercises. In Reading Exercise 1, MRI of the hip of 20 subjects were read at a single time point followed by further standardization of methodology. In Reading Exercise 2, MRI of the hip of 18 subjects from a randomized controlled trial, assessed at 2 timepoints, and 27 subjects from a cross-sectional study were read for HIMRISS and HOAMS bone marrow lesions (BML) and synovitis. Reliability was assessed using intraclass correlation coefficient (ICC) and kappa statistics. Both methods were considered feasible. For Reading 1, HIMRISS ICC were 0.52, 0.61, 0.70, and 0.58 for femoral BML, acetabular BML, effusion, and total scores, respectively; and for HOAMS, summed BML and synovitis ICC were 0.52 and 0.46, respectively. For Reading 2, HIMRISS and HOAMS ICC for BML and synovitis-effusion improved substantially. Interobserver reliability for change scores was 0.81 and 0.71 for HIMRISS femoral and HOAMS summed BML, respectively. Responsiveness and discrimination was moderate to high for synovitis-effusion. Significant associations were noted between BML or synovitis scores and Western Ontario and McMaster Universities Osteoarthritis Index pain scores for baseline values (p ≤ 0.001). The BML and synovitis-effusion components of both HIMRISS and HOAMS scoring systems are feasible and reliable, and should be validated further.

  14. A multi-modality tracking, navigation and calibration for a flexible robotic drill system for total hip arthroplasty.

    Science.gov (United States)

    Ahmad Fuad, Ahmad Nazmi Bin; Deep, Kamal; Yao, Wei

    2018-02-01

    This paper presents a novel multi-modality tracking and navigation system that provides a unique capability to guild a flexible drill tip inside the bone with accurate curved tunnelling. As the flexible drill tip cannot be tracked optically inside the bone, this research focuses on developing a hybrid tracking and navigation system for tracking a flexible drill tip by using both optical and kinematic tracking. The tracking information is used to guide the THA (total hip arthroplasty) procedure, providing a real-time virtual model of the flexible drill. The flexible and steerable drill tip system is then tested on total hip arthroplasty followed by evaluation of the positioning and orientation of femoral stem placement by femoral milling. Based on this study, we conclude that the tracking and navigation system is able to guide the flexible drill to mill inside femoral canal. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Understanding Total Hip Replacement Recovery towards the Design of a Context-Aware Systems

    NARCIS (Netherlands)

    Jimenez Garcia, Juan

    2011-01-01

    Total Hip Replacement (THR) is a common procedure to improve the mobility of elderly with osteoarthritis. Presently information about the recovery process after discharge is unclear. As consequence patients and physiotherapists face uncertainties to follow an adequate trajectory for recovery.

  16. Total hip arthroplasty outcomes assessment using functional and radiographic scores to compare canine systems.

    Science.gov (United States)

    Iwata, D; Broun, H C; Black, A P; Preston, C A; Anderson, G I

    2008-01-01

    A retrospective multi-centre study was carried out in order to compare outcomes between cemented and uncemented total hip arthoplasties (THA). A quantitative orthopaedic outcome assessment scoring system was devised in order to relate functional outcome to a numerical score, to allow comparison between treatments and amongst centres. The system combined a radiographic score and a clinical score. Lower scores reflect better outcomes than higher scores. Consecutive cases of THA were included from two specialist practices between July 2002 and December 2005. The study included 46 THA patients (22 uncemented THA followed for 8.3 +/- 4.7M and 24 cemented THA for 26.0 +/- 15.7M) with a mean age of 4.4 +/- 3.3 years at surgery. Multi-variable linear and logistical regression analyses were performed with adjustments for age at surgery, surgeon, follow-up time, uni- versus bilateral disease, gender and body weight. The differences between treatment groups in terms of functional scores or total scores were not significant (p > 0.05). Radiographic scores were different between treatment groups. However, these scores were usually assessed within two months of surgery and proved unreliable predictors of functional outcome (p > 0.05). The findings reflect relatively short-term follow-up, especially for the uncemented group, and do not include clinician-derived measures, such as goniometry and thigh circumference. Longer-term follow-up for the radiographic assessments is essential. A prospective study including the clinician-derived outcomes needs to be performed in order to validate the outcome instrument in its modified form.

  17. A Stereophotogrammetric System For The Detection Of Prosthesis Loosening In Total Hip Arthroplasty

    Science.gov (United States)

    Baumrind, Sheldon; Genant, Harry K.; Hunter, John; Miller, David; Moffitt, Francis; Murray, William R.; Ross, Steven E.

    1980-07-01

    Loosening of the prosthetic device occurs in about 5% of cases following placement of total hip prostheses (THP). Early detection of loosening is much desired but is difficult to achieve using conventional methods. Due to errors of projection, it is quite possible to fail to detect mobility of even as much as 5 mm on single x-ray films. We are attempting to develop a simplified photogrammetric system suitable for general hospital use which could detect loosening of 0.8 mm at the 95 % level of confidence without use of complex stereoplotting equipment. Metal reference markers are placed in the shaft of the femur and in the acetabular region of the pelvis at the time of surgery. The distances between these reference markers and certain unambiguous points on the prostheses are computed analytically using an X-Y acoustical digitizer (accuracy ± 0.1 mm) and software developed previously for craniofacial measurement. Separate stereopairs of the joint region are taken under weight-bearing and nonweight-bearing conditions. Differences in the measured distances between the bo-ne markers and the prosthetic components on the two stereopairs are taken as indicators of prosthesis loosening. Measurements on a phantom using ten different x-ray stereopairs taken from as many different perspectives have established that true linear distances between reference points and prostheses can be measured at the desired reliability with the present low precision system. Preliminary in vivo measurements indicate that the main unresolved problem is the movement of the subject between the two exposures of each single stereopair. Two possible solutions to this problem are discussed.

  18. Hip ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Martinoli, Carlo, E-mail: carlo.martinoli@libero.it [Radiologia, DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Garello, Isabella; Marchetti, Alessandra; Palmieri, Federigo; Altafini, Luisa [Radiologia, DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Valle, Maura [Radiologia, Gaslini Children Hospital, Genova (Italy); Tagliafico, Alberto [Radiologia, National Institute for Cancer Research, Genoa (Italy)

    2012-12-15

    In newborns, US has an established role in the detection and management of developmental dysplasia of the hip. Later in childhood, when the limping child is a major diagnostic dilemma, US is extremely helpful in the identification of the varied disease processes underlying this condition, as transient synovitis, septic arthritis, Perthes disease and slipped femoral capital epiphysis. In adolescent practicing sporting activities, US is an excellent means to identify apophyseal injures about the pelvic ring, especially when avulsions are undisplaced and difficult-to-see radiographically. Later on, in the adulthood, US is an effective modality to diagnose tendon and muscle injuries about the hip and pelvis, identify effusion or synovitis within the hip joint or its adjacent bursae and guide the treatment of these findings. The aim of this article is to provide a comprehensive review of the most common pathologic conditions about the hip, in which the contribution of US is relevant for the diagnostic work-up.

  19. Hip arthroscopy

    Directory of Open Access Journals (Sweden)

    Henrique Antônio Berwanger de Amorim Cabrita

    2015-06-01

    Full Text Available Hip arthroscopy is a safe method for treating a variety of pathological conditions that were unknown until a decade ago. Femoroacetabular impingement is the commonest of these pathological conditions and the one with the best results when treated early on. The instruments and surgical technique for hip arthroscopy continue to evolve. New indications for hip arthroscopy has been studied as the ligamentum teres injuries, capsular repair in instabilities, dissection of the sciatic nerve and repair of gluteal muscles tears (injuries to the hip rotator cuff, although still with debatable reproducibility. The complication rate is low, and ever-better results with fewer complications should be expected with the progression of the learning curve.

  20. Spine–hip relations in patients with hip osteoarthritis

    Science.gov (United States)

    Rivière, Charles; Lazic, Stefan; Dagneaux, Louis; Van Der Straeten, Catherine; Cobb, Justin; Muirhead-Allwood, Sarah

    2018-01-01

    Patients with hip osteoarthritis often have an abnormal spine-hip relation (SHR), meaning the presence of a clinically deleterious spine-hip and/or hip-spine syndrome. Definition of the individual SHR is ideally done using the EOS® imaging system or, if not available, with conventional lumbopelvic lateral radiographs. By pre-operatively screening patients with abnormal SHR, it is possible to refine total hip replacement (THR) surgical planning, which may improve outcomes. An important component of the concept of kinematically aligned total hip arthroplasty (KA THA) consists of defining the optimal acetabular cup design and orientation based on the assessment of an individual’s SHR, and use of the transverse acetabular ligament to adjust the cup positioning. The Bordeaux classification might advance the understanding of SHR and hopefully help improve THR outcomes. Cite this article: EFORT Open Rev 2018;3:39-44. DOI: 10.1302/2058-5241.3.170020 PMID:29657844

  1. THE SYSTEM OF TREATMENT OF HIP DYSPLASIA IN CHILDREN (CONCEPTION OF SRICO N.A. H.I. TURNER

    Directory of Open Access Journals (Sweden)

    Mikhail Mikhailovich Kamosko

    2013-03-01

    Full Text Available The system of treatment of hip dysplasia that is developed, applied and perfected at FSBI "Scientific and Research Institute for Children's Orthopedics n.a. H. Turner" involves the early entirely functional treatment (Lorenz method, other methods are similar in gist, providing immobilization with a cast or other devices, are not applied. The operative therapy is performed in primary patients with intrauterine or teratogenic dislocations of the hip. Technology of operative treatment is extremely gentle, sparing. Operations on deepening of socket, iatrogenic affection on cartilage cover, capsular arthroplasty are excluded from the arsenal of surgeons. Anatomy of a children’s dysplastic of hip joints (not subjected to inappropriate conservative or surgical treatment has several fairly standard options. For each option, there is a combination of classical operational techniques (tenomyotomy of lumbar-iliac muscle, capsulotomy, detorsion, varization, shortening, medialization, changes in the spatial orientation of the arch or of the whole acetabulum, which have proven on the vast clinical material to be very effective with the right technical performance.

  2. Dose attenuation effect of hip prostheses in a 9-MV photon beam. Commercial treatment planning system versus Monte Carlo calculations

    International Nuclear Information System (INIS)

    Mesbahi, A.; Nejad, F.S.

    2007-01-01

    The purpose of this study was to investigate the dosimetric effect of various hip prostheses on pelvis lateral fields treated by a 9-MV photon beam using Monte Carlo (MC) and effective path-length (EPL) methods. The head of the Neptun 10 pc linac was simulated using the MCNP4C MC code. The accuracy of the MC model was evaluated using measured dosimetric features including depth dose values and dose profiles in a water phantom. The Alfard treatment planning system (TPS) was used for EPL calculations. A virtual water phantom with dimensions of 30 x 30 x 30 cm 3 and a cube with dimensions of 4 x 4 x 4 cm 3 made of various metals centered in 12 cm depth was used for MC and EPL calculations. Various materials including titanium, Co-Cr-Mo, and steel alloys were used as hip prostheses. Our results showed significant attenuation in absorbed dose for points after and inside the prostheses. Attenuations of 32%, 54% and 55% were seen for titanium, Co-Cr-Mo, and steel alloys, respectively, at a distance of 5 cm from the prosthesis. Considerable dose increase (up to 18%) was found at the water-prosthesis interface due to back-scattered electrons using the MC method. The results of EPL calculations for the titanium implant were comparable to the MC calculations. This method, however, was not able to predict the interface effect or calculate accurately the absorbed dose in the presence of the Co-Cr-Mo and steel prostheses. The dose perturbation effect of hip prostheses is significant and cannot be predicted accurately by the EPL method for Co-Cr-Mo or steel prostheses. The use of MC-based TPS is recommended for treatments requiring fields passing through hip prostheses. (author)

  3. The stability of the femoral component of a minimal invasive total hip replacement system.

    NARCIS (Netherlands)

    Willems, M.M.M.; Kooloos, J.G.M.; Gibbons, P.; Minderhoud, N.; Weernink, T.; Verdonschot, N.J.J.

    2006-01-01

    In this study, the initial stability of the femoral component of a minimal invasive total hip replacement was biomechanically evaluated during simulated normal walking and chair rising. A 20 mm diameter canal was created in the femoral necks of five fresh frozen human cadaver bones and the femoral

  4. Ten different hip resurfacing systems: biomechanical analysis of design and material properties.

    Science.gov (United States)

    Heisel, Christian; Kleinhans, Jennifer A; Menge, Michael; Kretzer, Jan Philippe

    2009-08-01

    This study gives an overview of the main macro- and microstructural differences of ten commercially available total hip resurfacing implants. The heads and cups of resurfacing hip implants from ten different manufacturers were analysed. The components were measured in a coordinate measuring machine. The microstructure of the heads and cups was inspected by scanning electron microscopy. The mean radial clearance was 84.86 microm (range: 49.47-120.93 microm). The implants were classified into three groups (low, medium and high clearance). All implants showed a deviation of roundness of less than 10 microm. It was shown that all implants differ from each other and a final conclusion about the ideal design and material combination cannot be given based on biomechanical data. Widespread use of specific designs can only be recommended if clinical long-term follow-up studies are performed and analysed for each design.

  5. THE USE OF SPECIALIST SYSTEMS FOR SUPPORT TO ORGANIZATION IN ORTHOPEDICAL EXAMS OF THE HIP, KNEE AND ANKLE

    Directory of Open Access Journals (Sweden)

    Jefferson Paixão Cardoso

    2005-09-01

    Full Text Available This study aims at, mainly, to show that expert systems can be used for support to the systenmatization in orthopedic exams. In that perspective, a prototype of expert system was generated for orthopedic exams of hip, knee and ankle starting from Shell of Artificial Intelligence Expert SINTA, seeking to evaluate as the expert systems can contribute in practice of the professional as well as of the student in Physiotherapy. With that, initially the proposal was divided in two stages: development of the expert system prototype and evaluation of the system for professionals and discentes of the Course of Physiotherapy of the Universidade Estadual do Sudoeste da Bahia - UESB - Campus of Jequié. In that study we will present the results obtained in the first stage, development of the prototype of the expert system. For accomplishment of the work it was necessary the involvement of teachers of the computation area and health and students of the Course of Physiotherapy.

  6. Novel anthropomorphic hip phantom corrects systemic interscanner differences in proximal femoral vBMD

    International Nuclear Information System (INIS)

    Bonaretti, S; Saeed, I; Burghardt, A J; Lang, T; Carpenter, R D; Yu, L; Bruesewitz, M; Khosla, S

    2014-01-01

    Quantitative computed tomography (QCT) is increasingly used in osteoporosis studies to assess volumetric bone mineral density (vBMD), bone quality and strength. However, QCT is confronted by technical issues in the clinical research setting, such as potentially confounding effects of body size on vBMD measurements and lack of standard approaches to scanner cross-calibration, which affects measurements of vBMD in multicenter settings. In this study, we addressed systematic inter-scanner differences and subject-dependent body size errors using a novel anthropomorphic hip phantom, containing a calibration hip to estimate correction equations, and a contralateral test hip to assess the quality of the correction. We scanned this phantom on four different scanners and we applied phantom-derived corrections to in vivo images of 16 postmenopausal women scanned on two scanners. From the phantom study, we found that vBMD decreased with increasing phantom size in three of four scanners and that inter-scanner variations increased with increasing phantom size. In the in vivo study, we observed that inter-scanner corrections reduced systematic inter-scanner mean vBMD differences but that the inter-scanner precision error was still larger than expected from known intra-scanner precision measurements. In conclusion, inter-scanner corrections and body size influence should be considered when measuring vBMD from QCT images. (paper)

  7. Ultrasonography of the painful hip in childhood

    NARCIS (Netherlands)

    S.G.F. Robben (Simon)

    1999-01-01

    textabstractThere are many diseases in childhood that affect the hip joint. Some diseases are systemic in origin and initially may present themselves as hip disorders, such as rheumatoid arthritis. other diseases are localized specifically in the hip joint, such as transient synovitis and Perthes'

  8. Osteosynthesis of femoral neck fractures: dynamic hip screw (DHS or mini-invasive Targon FN system?

    Directory of Open Access Journals (Sweden)

    A. K. Dulaev

    2015-01-01

    Full Text Available Objectives: to investigate the long-term outcomes of femoral neck fractures that were surgically fixed using various types of extramedullary implants in patients aged 65 years and younger. Material and methods: We analyzed the clinical results of surgical treatment of femoral neck fractures by extramedullary osteosynthesis in 94 patients aged 38 to 65 years old (71 women and 23 men. The patients were divided into 3 groups according to AO/ASIF fracture classification. We used different techniques of osteosynthesis: with DHS or with Targon FN. In all patients the mental status rate SPMSQ, osteoporosis degree (Singh index, general somatic status (WHO scale were evaluated in the preoperative period. We also evaluated next intraoperative parameters: duration of surgery, blood loss, quality of reduction, long of incision. In a year after surgery we assessed functional results (Harris Hip Score and analysed postoperative complications. Results: It was found the inverse correlation (r = -0,8 of total preoperative parameters (WHO scale, the Singh index and mental status SPMSQ and postoperative functional results on Harris Hip Score. With the reliability of p<0.05 the average rate of blood loss and length of skin incision were less in patients operated with Targon FN. In 12 months unsatisfactory results rate on Harris Hip Score was 12.7% in all study groups, great - 22,3%, good - 52.1%, and satisfactory - 12,9%. Complications rate in patients operated with DHS was 17,02%, and in patients operated with Targon FN - 18.1%. Conclusion: Minimally invasive osteosynthesis of femoral neck fractures (type B1 and B2 on AO/ASIF classification allows to achieve the best results in compare with DHS osteosynthesis. Revealed complications such as screw migration, false joint formation and femoral head avascular necrosis were determined by impaired surgical technique and inadequate reduction.

  9. Hip dysplasia and congenital hip dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Lingg, G.; Nebel, G.; von Torklus, D.

    1981-11-01

    In human genetics and orthopedics quite different answers have been given to the question of hereditary transmission and frequency of hip dysplasia in families of children with congenital hip dislocation. We therefore have made roentgenometric measurements of 110 parents of children with congenital hip dislocation. In 25% we found abnormal flat acetabulae, whereas 12% had pathologic deep hips. This may propose a new concept of morphology of congenital hip dysplasia.

  10. Different hip and knee priority score systems: are they good for the same thing?

    Science.gov (United States)

    Escobar, Antonio; Quintana, Jose Maria; Espallargues, Mireia; Allepuz, Alejandro; Ibañez, Berta

    2010-10-01

    The aim of the present study was to compare two priority tools used for joint replacement for patients on waiting lists, which use two different methods. Two prioritization tools developed and validated by different methodologies were used on the same cohort of patients. The first, an IRYSS hip and knee priority score (IHKPS) developed by RAND method, was applied while patients were on the waiting list. The other, a Catalonia hip-knee priority score (CHKPS) developed by conjoint analysis, was adapted and applied retrospectively. In addition, all patients fulfilled pre-intervention the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Correlation between them was studied by Pearson correlation coefficient (r). Agreement was analysed by means of intra-class correlation coefficient (ICC), Kendall coefficient and Cohern kappa. The relationship between IHKPS, CHKPS and baseline WOMAC scores by r coefficient was studied. The sample consisted of 774 consecutive patients. Pearson correlation coefficient between IHKPS and CHKPS was 0.79. The agreement study showed that ICC was 0.74, Kendall coefficient 0.86 and kappa 0.66. Finally, correlation between CHKPS and baseline WOMAC ranged from 0.43 to 0.64. The results according to the relationship between IHKPS and WOMAC ranged from 0.50 to 0.74. Results support the hypothesis that if the final objective of the prioritization tools is to organize and sort patients on the waiting list, although they use different methodologies, the results are similar. © 2010 Blackwell Publishing Ltd.

  11. Grave fraudulence in medical device research: a narrative review of the PIN seeding study for the Pinnacle hip system.

    Science.gov (United States)

    Steffen, Joan E; Fassler, Ella A; Reardon, Kevin J; Egilman, David S

    2018-01-01

    In 2001, DePuy, a wholly-owned subsidiary of Johnson & Johnson (J&J/DePuy), initiated a seeding study called the "Multi-center, Prospective, Clinical Evaluation of Pinnacle Acetabular Implants in Total Hip Arthroplasty" (PIN Study). J&J/DePuy designed this study to develop new business opportunities during the launch of their Pinnacle Hip System (PHS) and generate survivorship data for marketing. This article, the first review of a seeding trial for a medical device, examines internal company documents relating to the PIN Study; the analysis herein focuses on the integrity of J&J/DePuy's research practices in conception, implementation, and analysis. J&J/DePuy violated the study protocol and manipulated data; consented participants in violation of standards protecting human subjects; and did not secure Institutional Review Board approval for all study sites. J&J/DePuy used PIN Study results as the "fundamental selling point" for the PHS. Medical device seeding trials are distinct from previously-documented pharmaceutical seeding trials because companies can profit directly from device sales and because these studies may be the first clinical evaluation of the device (as was the case for the PIN Study). Seeding trials are malleable marketing projects, not rigorous scientific studies. Regulatory bodies, physicians, and others should be vigilant for persuasive marketing accounts disguised as science.

  12. Support for total hip replacement surgery: Structures modeling, Gait Data Analysis and Report system

    Directory of Open Access Journals (Sweden)

    Gianluca Mario Izzo

    2012-03-01

    Full Text Available For the treatment of advanced damages of hip joints, Total Hip Arthroplasty is well proven. Due to the different mechanical properties of the prosthesis material and the bone tissue, a partial unloading of the periprosthetic bone occurs. The bone cement causes reduction in bone density as a result of removal of normal stress from the bone, leading to weakening of the bone in that area and the fracture risk increases. Bone loss is identified as one of the main reasons for loosening of the stem. Otherwise, thanks to the press-fit of the non-cemented stem achieved by surgery, the bone layers immediately adjacent to the stem are preloaded, thus encouraged growing, and the bone getting stronger. The non-cemented stem would be the better choice for every patient, but the question remains if the femur can handle the press- fitting surgery. This studies aim to develop a monitoring techniques based on Gait analysis and bone density changes to assess patient recovery after Total Hip Arthroplasty. Furthermore, to validate computational processes based on 3D modeling and Finite Element Methods for optimizing decision making in the operation process and selecting the suited surgical procedure. A vision could be minimizing risk of periprosthetic fracture during and after surgery. Patients: The sample presents 11 patients receiving cemented implant and 13 for the uncemented. Patients are grouped by type of implant. Three checkpoints were considered: before, after operation and one year later. CT scans, gaitrite and kinepro measurements have been realized. Main outcome measures: Fracture risk probability is higher in bone with low bone mineral density; therefore bones are more fragile in elderly people. BMD is indeed one parameter considered among all the observations. Periprosthetic fracture of the femur is a rare but complex complication of THA, and requires demanding surgery. As such, they result in considerable morbidity and dysfunction. Thus, tests of

  13. Systemic distribution of wear debris after hip replacement. A cause for concern?

    Science.gov (United States)

    Langkamer, V G; Case, C P; Heap, P; Taylor, A; Collins, C; Pearse, M; Solomon, L

    1992-11-01

    The production of particulate wear debris is a recognised complication of joint arthroplasty, but interest has concentrated on local tissue reactions and a possible association with implant loosening. The fate of wear products in the body remains unknown, although some of the metals used in the construction of orthopaedic implants are known to have toxic and oncogenic properties. We report histological and electron-microscopic evidence from two cases which shows that metallic debris can be identified in the lymphoreticular tissues of the body distant from the hip some years after joint replacement. The increase in the use of total arthroplasty in younger patients, the development of new alloys and the use of porous coatings must raise concern for the long-term effects of the accumulation of wear debris in the body.

  14. Hip Injuries and Disorders

    Science.gov (United States)

    Your hip is the joint where your femur (thigh bone) meets your pelvis (hip bone). There are two main parts: a ball ... fits in a socket in the pelvis. Your hip is known as a ball-and-socket joint. ...

  15. Hip Replacement Surgery

    Science.gov (United States)

    ... Outreach Initiative Breadcrumb Home Health Topics English Español Hip Replacement Surgery Basics In-Depth Download Download EPUB ... PDF What is it? Points To Remember About Hip Replacement Surgery Hip replacement surgery removes damaged or ...

  16. Femoral head fracture without hip dislocation

    Directory of Open Access Journals (Sweden)

    Aggarwal Aditya K

    2013-10-01

    Full Text Available 【Abstract】Femoral head fractures without dislocation or subluxation are extremely rare injuries. We report a neglected case of isolated comminuted fracture of femoral head without hip dislocation or subluxation of one year duration in a 36-year-old patient who sustained a high en- ergy trauma due to road traffic accident. He presented with painful right hip and inability to bear full weight on right lower limb with Harris hip score of 39. He received cementless total hip replacement. At latest follow-up of 2.3 years, functional outcome was excellent with Harris hip score of 95. Such isolated injuries have been described only once in the literature and have not been classified till now. The purpose of this report is to highlight the extreme rarity, possible mechanism involved and a novel classification system to classify such injuries. Key words: Femur head; Hip dislocation; Classification; Arthroplasty, replacement, hip

  17. Benefits of Hot Isostatic Pressure/Powdered Metal (HIP/PM) and Additive Manufacturing (AM) To Fabricate Advanced Energy System Components

    Energy Technology Data Exchange (ETDEWEB)

    Horton, Nancy [Energy Industries of Ohio, Cleveland, OH (United States); Sheppard, Roy [Energy Industries of Ohio, Cleveland, OH (United States)

    2016-12-31

    Advanced Energy systems require large, complex components produced from materials capable of withstanding severe operating environments (high temperature, pressure, corrosivity). Such parts can be difficult to source, as conventional material processing technologies must be tailored to ensure a safe and cost effective approach to large-scale manufacture of quality structural advanced alloy components that meet the performance specifications of AE systems. (HIP/PM) has shown advantages over other manufacturing methods when working with these materials. For example, using HIP’ing in lieu of casting means significant savings in raw material costs, which for expensive, high-nickel alloys can be considerable for large-scale production. Use of HIP/PM also eliminates the difficulties resulting from reactivity of these materials in the molten state and facilitates manufacture of the large size requirements of the AE industry, producing a part that is defect and porosity free, thus further reducing or eliminating time and expense of post processing machining and weld repair. New advances in Additive Manufacturing (AM) techniques make it possible to further expand the benefits of HIP/PM in producing AE system components to create an even more robust manufacturing approach. Traditional techniques of welding and forming sheet metal to produce the HIP canisters can be time consuming and costly, with limitations on the complexity of part which can be achieved. A key benefit of AM is the freedom of design that it offers, so use of AM could overcome such challenges, ultimately enabling redesign of complete energy systems. A critical step toward this goal is material characterization of the required advanced alloys, for use in AM. Using Haynes 282, a high nickel alloy of interest to the Fossil Energy community, particularly for Advanced-UltraSuperCritical (AUSC) operating environments, as well as the crosscutting interests of the aerospace, defense and medical markets, this

  18. IMU-based Real-time Pose Measurement system for Anterior Pelvic Plane in Total Hip Replacement Surgeries.

    Science.gov (United States)

    Zhe Cao; Shaojie Su; Hao Tang; Yixin Zhou; Zhihua Wang; Hong Chen

    2017-07-01

    With the aging of population, the number of Total Hip Replacement Surgeries (THR) increased year by year. In THR, inaccurate position of the implanted prosthesis may lead to the failure of the operation. In order to reduce the failure rate and acquire the real-time pose of Anterior Pelvic Plane (APP), we propose a measurement system in this paper. The measurement system includes two parts: Initial Pose Measurement Instrument (IPMI) and Real-time Pose Measurement Instrument (RPMI). IPMI is used to acquire the initial pose of the APP, and RPMI is used to estimate the real-time pose of the APP. Both are composed of an Inertial Measurement Unit (IMU) and magnetometer sensors. To estimate the attitude of the measurement system, the Extended Kalman Filter (EKF) is adopted in this paper. The real-time pose of the APP could be acquired together with the algorithm designed in the paper. The experiment results show that the Root Mean Square Error (RMSE) is within 1.6 degrees, which meets the requirement of THR operations.

  19. Technical note: validation of a motion analysis system for measuring the relative motion of the intermediate component of a tripolar total hip arthroplasty prosthesis.

    Science.gov (United States)

    Chen, Qingshan; Lazennec, Jean Yves; Guyen, Olivier; Kinbrum, Amy; Berry, Daniel J; An, Kai-Nan

    2005-07-01

    Tripolar total hip arthroplasty (THA) prosthesis had been suggested as a method to reduce the occurrence of hip dislocation and microseparation. Precisely measuring the motion of the intermediate component in vitro would provide fundamental knowledge for understanding its mechanism. The present study validates the accuracy and repeatability of a three-dimensional motion analysis system to quantitatively measure the relative motion of the intermediate component of tripolar total hip arthroplasty prostheses. Static and dynamic validations of the system were made by comparing the measurement to that of a potentiometer. Differences between the mean system-calculated angle and the angle measured by the potentiometer were within +/-1 degrees . The mean within-trial variability was less than 1 degrees . The mean slope was 0.9-1.02 for different angular velocities. The dynamic noise was within 1 degrees . The system was then applied to measure the relative motion of an eccentric THA prosthesis. The study shows that this motion analysis system provides an accurate and practical method for measuring the relative motion of the tripolar THA prosthesis in vitro, a necessary first step towards the understanding of its in vivo kinematics.

  20. HIP JOINT AND HIP ENDOPROSTHESIS BIOMECHANICS

    OpenAIRE

    Jakub Gryka

    2017-01-01

    This article contains a description of the basic issues related to anatomy, loading of hip joint and its endoprosthesis research methods. The methods of testing and simulating hip joint loads, factors that influence the selection of parameters during the design of prostheses, typical solutions to engineering problems related to this topic are presented. The article concludes with short summary of the finite element method for the design of hip replacements.

  1. Assessment of the hip reduction angle for predicting osteoarthritis of the hip in the Labrador Retriever.

    Science.gov (United States)

    Corfield, G S; Read, R A; Eastley, K A; Richardson, J L; Robertson, I D; Day, R

    2007-06-01

    Hip palpation has been used to provide semiquantitative information regarding passive joint laxity and susceptibility to hip dysplasia. The purpose of this study was to: (1) evaluate the intra- and inter-examiner repeatability of the hip reduction angle measured at 4 months of age by three examiners using manual goniometry and an electromagnetic tracking system; (2) compare the hip reduction angle measured with manual goniometry to the hip reduction angle measured with the electromagnetic tracking system; and (3) evaluate the hip reduction angle, distraction index and Ortolani manoeuvre at 4 months of age as predictors of the development of hip osteoarthritis at 12 months of age in 11 Labrador Retriever dogs. Intra- and inter-examiner repeatability was demonstrated for both the manual and electromagnetic goniometric measurement of the hip reduction angle (coefficient of variation goniometry was moderately correlated to the hip reduction angle measured by the electromagnetic tracking system (r = 0.603, P goniometry was a poor predictor of osteoarthritis at 12 months of age (r = 0.231, P < 0.062, and r = 0.321, P < 0.01). The distraction index was moderately correlated with the development of osteoarthritis by 12 months of age (r = 0.493, P < 0.0000). The Ortolani sign was sensitive (100%) but not specific (41%) for the development of osteoarthritis at 12 months of age. The hip reduction angle did not further quantify the Ortolani manoeuvre as a predictor of osteoarthritis in Labrador Retrievers.

  2. The association between eccentric hip abduction strength and hip and knee angular movements in recreational male runners

    DEFF Research Database (Denmark)

    Brund, René B. Korsgaard; Rasmussen, Sten; Nielsen, Rasmus O.

    2018-01-01

    Weak hip abductors may be related with increased hip adduction and knee abduction angular movement, which may be risk factors of lower extremity injuries. As the role of eccentric hip abduction strength (EHAS) on hip adduction angular movement and knee abduction angular movement (KABD) remains...... and Codamotion active marker system. Using multiple linear regression models (n=186 legs), no relationships between EHAS and hip and knee kinematics were found. A possible reason for the lack of relationship between EHAS and hip and knee kinematics may be owing to differences in the running kinematics. Some...

  3. Do illness rating systems predict discharge location, length of stay, and cost after total hip arthroplasty?

    Directory of Open Access Journals (Sweden)

    Sarah E. Rudasill, BA

    2018-06-01

    Conclusions: These findings suggest that although ASA classifications predict discharge location and SOI scores predict length of stay and total costs, other factors beyond illness rating systems remain stronger predictors of discharge for THA patients.

  4. Hip fracture - discharge

    Science.gov (United States)

    ... neck fracture repair - discharge; Trochanteric fracture repair - discharge; Hip pinning surgery - discharge ... in the hospital for surgery to repair a hip fracture, a break in the upper part of ...

  5. Hip joint replacement - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100006.htm Hip joint replacement - series—Normal anatomy To use the ... to slide 5 out of 5 Overview The hip joint is made up of two major parts: ...

  6. Hip Labral Tear

    Science.gov (United States)

    ... that joint in the future. Prevention Hip labral tears are often associated with sports participation. If your sport puts a lot of strain on your hips, condition the surrounding muscles with strength and flexibility exercises. Try to avoid ...

  7. HPLC/DAD Intercomparison on Phytoplankton Pigments (HIP-1, HIP-2, HIP-3 and HIP-4)

    OpenAIRE

    CANUTI Elisabetta; RAS Josephine; GRUNG Merete; ROTTGERS Rudiger; COSTA GOELA Priscilla; ARTUSO Florinda; CATALDI Dario

    2016-01-01

    From 2009 to 2015, in the context of the MERIS (Medium Resolution Imaging Spectrometer) validation activities, the JRC Marine Optical Laboratory organised four HPLC Intercomparison exercises for Phytoplankton Pigment measurements (HIP-1, HIP-2, HIP-3 and HIP-4), involving seven European accredited and reference laboratories. The objectives of these intercomparison exercises were: creating a reference community at European level for phytoplankton pigment analysis capable of supporting satel...

  8. Hip supporting device

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a device for limiting movements in one or more anatomical joints, such as a device for limiting movement in the human hip joint after hip replacement surgery. This is provided by a device for limiting movement in the human hip joint, said device comprising: at least...

  9. Bursitis of the Hip

    Science.gov (United States)

    ... difficile (C. diff.) InfectionHerpes Home Diseases and Conditions Bursitis of the Hip Condition Bursitis of the Hip Share Print Table of Contents1. ... Prevention5. Treatment6. Everyday Life7. Questions8. Resources What is bursitis of the hip? Bursitis is the painful swelling ...

  10. HIPs at Ten

    Science.gov (United States)

    Kuh, George; O'Donnell, Ken; Schneider, Carol Geary

    2017-01-01

    2017 is the anniversary of the introduction of what are now commonly known as high-impact practices (HIPs). Many of the specific activities pursued under the HIPs acronym have been around in some form for decades, such as study abroad, internships, and student-faculty research. It was about ten years ago that, after conferring HIPs at Ten with…

  11. [Evaluation of selected parameters of blood coagulation and fibrinolysis system in patients undergoing total hip replacement surgery with normovolemic hemodilution procedure and standard enoxaparine prophylaxis].

    Science.gov (United States)

    Piecuch, Wiesław; Sokołowska, Bozena; Dmoszyńska, Anna; Furmanik, Franciszek

    2003-01-01

    The aim of the study was to evaluate selected blood coagulation and fibrinolysis parameters in patients undergoing total hip replacement surgery with normovolemic hemodilution and standard enoksaparine profilaxis. The study included 66 patients undergoing hip replacement surgery. The group consisted of 51 women and 15 men, within the age range of 47-78, the mean age was 64. In 32 (subgroup II) patients the surgery was performed with the use of normovolemic hemodilution, in 34 (subgroup I) the hemodilution procedure was not applied. The enoksaparine as prophylaxis started 12 hours prior to surgery and continued during hospitalisation. The examination of the coagulation system was performed: on the day of the operation in the morning, on the day of the operation in the evening and on the first day after operation. We determined the concentrations of TAT and PAP complexes, prothrombin fragments 1 + 2 (F1 + 2) and d-dimers (DD). 1) during total hip replacement surgery and particularly in the period of the first 12 hours after the procedure marked activation of coagulation and fibrinolysis occurRed; 2) the application of the hemodilution procedure does not influence significantly the degree of coagulation and fibrinolysis disorders in the perioperative period, but could reduced incidence of thromboembolic complications in the postoperative period.

  12. The skill of surface registration in CT-based navigation system for total hip arthroplasty

    International Nuclear Information System (INIS)

    Hananouchi, T.; Sugano, N.; Nishii, T.; Miki, H.; Sakai, T.; Yoshikawa, H.; Iwana, D.; Yamamura, M.; Nakamura, N.

    2007-01-01

    Surface registration of the CT-based navigation system, which is a matching between computational and real spatial spaces, is a key step to guarantee the accuracy of navigation. However, it has not been well described how the accuracy is affected by the registration skill of surgeon. Here, we reported the difference of the registration error between eight surgeons with the experience of navigation and six apprentice surgeons. A cadaveric pelvic model with an acetabular cup was made to measure the skill and learning curve of registration. After surface registration, two cup angles (inclination and anteversion) were recorded in the navigation system and the variance of these cup angles in ten trials were compared between the experienced surgeons and apprentices. In addition, we investigated whether the accuracy of registration by the apprentices was improved by visual information on how to take the surface points. The results showed that there was statistically significant difference in the accuracy of registration between the two groups. The accuracy of the second ten trials after getting the visual information showed great improvements. (orig.)

  13. Timing of surgery for hip fracture and in-hospital mortality: a retrospective population-based cohort study in the Spanish National Health System

    Directory of Open Access Journals (Sweden)

    Librero Julián

    2012-01-01

    Full Text Available Abstract Background While the benefits or otherwise of early hip fracture repair is a long-running controversy with studies showing contradictory results, this practice is being adopted as a quality indicator in several health care organizations. The aim of this study is to analyze the association between early hip fracture repair and in-hospital mortality in elderly people attending public hospitals in the Spanish National Health System and, additionally, to explore factors associated with the decision to perform early hip fracture repair. Methods A cohort of 56,500 patients of 60-years-old and over, hospitalized for hip fracture during the period 2002 to 2005 in all the public hospitals in 8 Spanish regions, were followed up using administrative databases to identify the time to surgical repair and in-hospital mortality. We used a multivariate logistic regression model to analyze the relationship between the timing of surgery ( Results Early surgery was performed on 25% of the patients. In the unadjusted analysis early surgery showed an absolute difference in risk of mortality of 0.57 (from 4.42% to 3.85%. However, patients undergoing delayed surgery were older and had higher comorbidity and severity of illness. Timeliness for surgery was not found to be related to in-hospital mortality once confounding factors such as age, sex, chronic comorbidities as well as the severity of illness were controlled for in the multivariate analysis. Conclusions Older age, male gender, higher chronic comorbidity and higher severity measured by the Risk Mortality Index were associated with higher mortality, but the time to surgery was not.

  14. Direct costs of osteoporosis and hip fracture: an analysis for the Mexican Social Insurance Health Care System.

    Science.gov (United States)

    Carlos, Fernando; Clark, Patricia; Maciel, Humberto; Tamayo, Juan A

    2009-01-01

    To compare costs of diagnosis and annual treatment of osteoporosis and hip fracture between the Instituto Nacional de Rehabilitación (INR) and the protocol used by the Seguro Popular de Salud (SPSS). Direct costs gathered in a prospective study with real cases at the INR are presented, and then this data is re-analyzed with the methodology and protocol for the SPSS to estimate the costs of those cases if treated with the SPSS protocol. Important differences were found in the cost of hip fracture: the SPSS estimates ($37,363.73 MXN) almost double the INR cost ($20,286.86 MXN ). This discrepancy was caused by the different types of surgeries the INR and SPSS protocols call for (the SPSS assumes that all hip fractures will necessitate a hip replacement) and the cost of subsequent hospitalization. A prospective study at the SPSS is needed to validate these results. Important differences were found between treatment of the same osteoporosis related problems at the INR and SPSS. We recommend revising the SPSS protocol to include less costly surgical treatments.

  15. Hip Resurfacing: An Alternative to Conventional Hip Replacement?

    Science.gov (United States)

    ... Is hip resurfacing a good alternative to hip replacement? Answers from Mark Spangehl, M.D. Hip resurfacing has lost favor with many surgeons ... women with poor bone quality. Unlike traditional hip replacement, hip resurfacing doesn't completely replace the "ball" ...

  16. Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion.

    Science.gov (United States)

    Charlton, Paula C; Mentiplay, Benjamin F; Pua, Yong-Hao; Clark, Ross A

    2015-05-01

    Traditional methods of assessing joint range of motion (ROM) involve specialized tools that may not be widely available to clinicians. This study assesses the reliability and validity of a custom Smartphone application for assessing hip joint range of motion. Intra-tester reliability with concurrent validity. Passive hip joint range of motion was recorded for seven different movements in 20 males on two separate occasions. Data from a Smartphone, bubble inclinometer and a three dimensional motion analysis (3DMA) system were collected simultaneously. Intraclass correlation coefficients (ICCs), coefficients of variation (CV) and standard error of measurement (SEM) were used to assess reliability. To assess validity of the Smartphone application and the bubble inclinometer against the three dimensional motion analysis system, intraclass correlation coefficients and fixed and proportional biases were used. The Smartphone demonstrated good to excellent reliability (ICCs>0.75) for four out of the seven movements, and moderate to good reliability for the remaining three movements (ICC=0.63-0.68). Additionally, the Smartphone application displayed comparable reliability to the bubble inclinometer. The Smartphone application displayed excellent validity when compared to the three dimensional motion analysis system for all movements (ICCs>0.88) except one, which displayed moderate to good validity (ICC=0.71). Smartphones are portable and widely available tools that are mostly reliable and valid for assessing passive hip range of motion, with potential for large-scale use when a bubble inclinometer is not available. However, caution must be taken in its implementation as some movement axes demonstrated only moderate reliability. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty: A Clinical and Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Fırat Ozan

    2014-01-01

    Full Text Available The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA. Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%, good in 17 patients (53.1%, average in 5 patients (15.6%, and poor in 1 patient (9.3%. Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%, fibrous union in 12 (37.5%, and no union in 6 (18.7%. FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery.

  18. Greater Trochanteric Fixation Using a Cable System for Partial Hip Arthroplasty: A Clinical and Finite Element Analysis

    Science.gov (United States)

    Ozan, Fırat; Koyuncu, Şemmi; Pekedis, Mahmut; Altay, Taşkın; Yıldız, Hasan; Toker, Gökhan

    2014-01-01

    The aim of the study was to investigate the efficacy of greater trochanteric fixation using a multifilament cable to ensure abductor lever arm continuity in patients with a proximal femoral fracture undergoing partial hip arthroplasty. Mean age of the patients (12 men, 20 women) was 84.12 years. Mean follow-up was 13.06 months. Fixation of the dislocated greater trochanter with or without a cable following load application was assessed by finite element analysis (FEA). Radiological evaluation was based on the distance between the fracture and the union site. Harris hip score was used to evaluate final results: outcomes were excellent in 7 patients (21.8%), good in 17 patients (53.1%), average in 5 patients (15.6%), and poor in 1 patient (9.3%). Mean abduction angle was 20.21°. Union was achieved in 14 patients (43.7%), fibrous union in 12 (37.5%), and no union in 6 (18.7%). FEA showed that the maximum total displacement of the greater trochanter decreased when the fractured bone was fixed with a cable. As the force applied to the cable increased, the displacement of the fractured trochanter decreased. This technique ensures continuity of the abductor lever arm in patients with a proximal femoral fracture who are undergoing partial hip arthroplasty surgery. PMID:25177703

  19. A biomechanical testing system to determine micromotion between hip implant and femur accounting for deformation of the hip implant: Assessment of the influence of rigid body assumptions on micromotions measurements.

    Science.gov (United States)

    Leuridan, Steven; Goossens, Quentin; Roosen, Jorg; Pastrav, Leonard; Denis, Kathleen; Mulier, Michiel; Desmet, Wim; Vander Sloten, Jos

    2017-02-01

    Accurate pre-clinical evaluation of the initial stability of new cementless hip stems using in vitro micromotion measurements is an important step in the design process to assess the new stem's potential. Several measuring systems, linear variable displacement transducer-based and other, require assuming bone or implant to be rigid to obtain micromotion values or to calculate derived quantities such as relative implant tilting. An alternative linear variable displacement transducer-based measuring system not requiring a rigid body assumption was developed in this study. The system combined advantages of local unidirectional and frame-and-bracket micromotion measuring concepts. The influence and possible errors that would be made by adopting a rigid body assumption were quantified. Furthermore, as the system allowed emulating local unidirectional and frame-and-bracket systems, the influence of adopting rigid body assumptions were also analyzed for both concepts. Synthetic and embalmed bone models were tested in combination with primary and revision implants. Single-legged stance phase loading was applied to the implant - bone constructs. Adopting a rigid body assumption resulted in an overestimation of mediolateral micromotion of up to 49.7μm at more distal measuring locations. Maximal average relative rotational motion was overestimated by 0.12° around the anteroposterior axis. Frontal and sagittal tilting calculations based on a unidirectional measuring concept underestimated the true tilting by an order of magnitude. Non-rigid behavior is a factor that should not be dismissed in micromotion stability evaluations of primary and revision femoral implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Reliability of sagittal plane hip, knee, and ankle joint angles from a single frame of video data using the GAITRite camera system.

    Science.gov (United States)

    Ross, Sandy A; Rice, Clinton; Von Behren, Kristyn; Meyer, April; Alexander, Rachel; Murfin, Scott

    2015-01-01

    The purpose of this study was to establish intra-rater, intra-session, and inter-rater, reliability of sagittal plane hip, knee, and ankle angles with and without reflective markers using the GAITRite walkway and single video camera between student physical therapists and an experienced physical therapist. This study included thirty-two healthy participants age 20-59, stratified by age and gender. Participants performed three successful walks with and without markers applied to anatomical landmarks. GAITRite software was used to digitize sagittal hip, knee, and ankle angles at two phases of gait: (1) initial contact; and (2) mid-stance. Intra-rater reliability was more consistent for the experienced physical therapist, regardless of joint or phase of gait. Intra-session reliability was variable, the experienced physical therapist showed moderate to high reliability (intra-class correlation coefficient (ICC) = 0.50-0.89) and the student physical therapist showed very poor to high reliability (ICC = 0.07-0.85). Inter-rater reliability was highest during mid-stance at the knee with markers (ICC = 0.86) and lowest during mid-stance at the hip without markers (ICC = 0.25). Reliability of a single camera system, especially at the knee joint shows promise. Depending on the specific type of reliability, error can be attributed to the testers (e.g. lack of digitization practice and marker placement), participants (e.g. loose fitting clothing) and camera systems (e.g. frame rate and resolution). However, until the camera technology can be upgraded to a higher frame rate and resolution, and the software can be linked to the GAITRite walkway, the clinical utility for pre/post measures is limited.

  1. Imaging of hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Theodore T., E-mail: millertt@hss.edu [Department of Radiology and Imaging, Hospital for Special Surgery, 535 E. 70th Street, New York, NY 10021 (United States)

    2012-12-15

    The imaging evaluation of the prosthetic hip begins with radiography, but arthrography, aspiration, scintigraphy, sonography, CT and MR imaging all have roles in the evaluation of the painful prosthesis. This article will review the appearance of normal hip arthroplasty including hemiarthroplasty, total arthroplasty, and hip resurfacing, as well as the appearances of potential complications such as aseptic loosening and osteolysis, dislocation, infection, periprosthetic fracture, hardware failure, and soft tissue abnormalities.

  2. Robotic hip arthroscopy in human anatomy.

    Science.gov (United States)

    Kather, Jens; Hagen, Monika E; Morel, Philippe; Fasel, Jean; Markar, Sheraz; Schueler, Michael

    2010-09-01

    Robotic technology offers technical advantages that might offer new solutions for hip arthroscopy. Two hip arthroscopies were performed in human cadavers using the da Vinci surgical system. During both surgeries, a robotic camera and 5 or 8 mm da Vinci trocars with instruments were inserted into the hip joint for manipulation. Introduction of cameras and working instruments, docking of the robotic system and instrument manipulation was successful in both cases. The long articulating area of 5 mm instruments limited movements inside the joint; an 8 mm instrument with a shorter area of articulation offered an improved range of motion. Hip arthroscopy using the da Vinci standard system appears a feasible alternative to standard arthroscopy. Instruments and method of application must be modified and improved before routine clinical application but further research in this area seems justified, considering the clinical value of such an approach. Copyright 2010 John Wiley & Sons, Ltd.

  3. Intravenous versus topical tranexamic acid in primary total hip replacement: A systemic review and meta-analysis.

    Science.gov (United States)

    Sun, Xiang; Dong, Qiang; Zhang, Yin-Guang

    2016-08-01

    Total hip arthroplasty (THA) is associated with substantial blood loss. Tranexamic acid (TXA) could reduce perioperative blood loss. The optimal administration routine of TXA remains controversial. The objective of the present systemic review and meta-analysis was to compare the effectiveness and safety of various application methods of tranexamic acid in primary THA. Potential relevant literature was identified from electronic databases including Medline, PubMed, Embase, ScienceDirect, web of science and Cochrane Library. Grey academic studies were also identified from the references of the included literature. There was no language restriction. The pooling of data was carried out by using RevMan 5.1. Three randomized controlled trials (RCTs) and two non-RCTs involving 1614 patients met the inclusion criteria. Current meta-analysis indicated that there were no significant differences in terms of total blood loss (MD = -30.04, 95% CI: -114.67 to 54.59, P = 0.49), postoperative hemoglobin level (MD = -0.29, 95% CI: -0.68 to 0.10, P = 0.14), transfusion rate (RD = -0.02, 95% CI: -0.5 to -0.00, P = 0.09), length of stay ((MD = -0.14, 95% CI: -0.30 to 0.01, P = 0.07) or operation time ((MD = 1.00, 95% CI: -0.31 to 2.31, P = 0.14) between treatment groups. No significant differences were found regarding the incidence of adverse effects such as wound infection (RD = -0.01, 95% CI: -0.06 to 0.04, P = 0.66), myocardial infarction (MI) (RD = -0.01, 95% CI: -0.04 to 0.02, P = 0.61), deep venous thrombosis (DVT) (RD = 0.00, 95% CI: -0.01 to 0.01, P = 0.51) or pulmonary embolism (PE) (RD = RD = 0.00, 95% CI: -0.01 to 0.01, P = 0.63) between groups. The topical administration of TXA in THA carried similar hemostasis effects compared with intravenous use without an increased risk of thrombotic complications. No other adverse effect was identified. Topical TXA application was a simple, safe, effective and cost-effective adjunct for

  4. Hip arthroplasty for ochronosis

    International Nuclear Information System (INIS)

    Kerimoglu, S.; Onder, C.; Aynaci, O.; Malkoc, C. H.

    2005-01-01

    Alkaptonuria is a metabolic disorder in which homogentisic acid oxidase is absent. Therefore, homogentisic acid accumulates in cartilage and connective tissues. We can diagnose ochronotic arthropathy, a manifestation of long standing alkaptonuria, through careful radiological, physical, and laboratory examination. In this report, we describe 4 cases of ochronotic arthropathy to which we applied cementless total hip prosthesis due to severe hip involvement. (author)

  5. Atraumatic Anterior Dislocation of the Hip Joint

    Directory of Open Access Journals (Sweden)

    Tadahiko Ohtsuru

    2015-01-01

    Full Text Available Dislocation of the hip joint in adults is usually caused by high-energy trauma such as road traffic accidents or falls from heights. Posterior dislocation is observed in most cases. However, atraumatic anterior dislocation of the hip joint is extremely rare. We present a case of atraumatic anterior dislocation of the hip joint that was induced by an activity of daily living. The possible causes of this dislocation were anterior capsule insufficiency due to developmental dysplasia of the hip, posterior pelvic tilt following thoracolumbar kyphosis due to vertebral fracture, and acetabular anterior coverage changes by postural factor. Acetabular anterior coverage changes in the sagittal plane were measured using a tomosynthesis imaging system. This system was useful for elucidation of the dislocation mechanism in the present case.

  6. Taking care of your new hip joint

    Science.gov (United States)

    Hip arthroplasty - precautions; Hip replacement - precautions; Osteoarthritis - hip; Osteoarthritis - knee ... After you have hip replacement surgery, you will need to be careful how you move your hip, especially for the first few months ...

  7. Early experience with dual mobility acetabular systems featuring highly cross-linked polyethylene liners for primary hip arthroplasty in patients under fifty five years of age: an international multi-centre preliminary study.

    Science.gov (United States)

    Epinette, Jean-Alain; Harwin, Steven F; Rowan, Fiachra E; Tracol, Philippe; Mont, Michael A; Chughtai, Morad; Westrich, Geoffrey H

    2017-03-01

    To evaluate early performance of contemporary dual mobility acetabular systems with second generation annealed highly cross-linked polyethylene for primary hip arthroplasty of patients under 55 years of age. A prospective observational five years study across five centers in Europe and the USA of 321 patients with a mean age of 48.1 years was performed. Patients were assessed for causes of revision, hip instability, intra-prosthetic dissociation, Harris hip score and radiological signs of osteolysis. There were no dislocations and no intra-prosthetic dissociations. Kaplan Meier analysis demonstrated 97.51% survivorship for all cause revision and 99.68% survivorship for acetabular component revision at five years. Mean Harris hip score was 93.6. Two acetabular shells were revised for neck-rim implant impingement without dislocation and ten femoral stems were revised for causes unrelated to dual mobility implants. Contemporary highly cross-linked polyethylene dual mobility systems demonstrate excellent early clinical, radiological, and survivorship results in a cohort of patients that demand high performance from their implants. It is envisaged that DM and second generation annealed HXLPE may reduce THA instability and wear, the two most common causes of THA revision in hip arthroplasty.

  8. Transient osteoporosis of the hip

    International Nuclear Information System (INIS)

    McWalter, Patricia; Hassan Ahmed

    2007-01-01

    Transient osteoporosis of the hip is an uncommon cause of hip pain, mostly affecting healthy middle-aged men and also women in the third trimester of pregnancy. We present a case of transient osteoporosis of the hip in a 33-year-old non-pregnant female patient. This case highlights the importance of considering a diagnosis of transient osteoporosis of the hip in patients who present with hip pain. (author)

  9. Transient osteoporosis of hip

    Directory of Open Access Journals (Sweden)

    Mahesh M Choudhary

    2015-01-01

    Full Text Available We report a case of transient osteoporosis of the hip (TOH in a 50-year-old man including the clinical presentation, diagnostic studies, management, and clinical progress. TOH is a rare self-limiting condition that typically affects middle-aged men or, less frequently, women in the third trimester of pregnancy. Affected individuals present clinically with acute hip pain, limping gait, and limited ranges of hip motion. TOH may begin spontaneously or after a minor trauma. Radiographs are typically unremarkable but magnetic resonance (MR imaging studies yield findings consistent with bone marrow edema. TOH is referred to as regional migratory osteoporosis (RMO if it travels to other joints or the contralateral hip. TOH often resembles osteonecrosis but the two conditions must be differentiated due to different prognoses and management approaches. The term TOH is often used interchangeably and synonymously with transient bone marrow edema (TBME.

  10. Danish Hip Arthroscopy Registry

    DEFF Research Database (Denmark)

    Mygind-Klavsen, Bjarne; Grønbech Nielsen, Torsten; Maagaard, Niels

    2016-01-01

    Danish Hip Arthroscopy Registry (DHAR) was initiated in 2012 as a web-based prospective registry. The purpose of this study was to evaluate and report the epidemiologic and perioperative data of the first 2000 procedures in a Danish hip arthroscopy population and to describe the development of DHAR...... was 0.65 and HAGOS sub-scores were 51 (pain), 49 (symptoms), 53 (ADL), 35 (sport), 20 (physical activity) and 29, respectively. We conclude that patients undergoing hip arthroscopy report considerable pain, loss of function, reduced level of activity and reduced quality-of-life prior to surgery....... The problems with development and maintaining a large clinical registry are described and further studies are needed to validate data completeness. We consider the development of a national clinical registry for hip arthroscopy as a successful way of developing and maintaining a valuable clinical...

  11. A computer-aided system for automatic extraction of femur neck trabecular bone architecture using isotropic volume construction from clinical hip computed tomography images.

    Science.gov (United States)

    Vivekanandhan, Sapthagirivasan; Subramaniam, Janarthanam; Mariamichael, Anburajan

    2016-10-01

    Hip fractures due to osteoporosis are increasing progressively across the globe. It is also difficult for those fractured patients to undergo dual-energy X-ray absorptiometry scans due to its complicated protocol and its associated cost. The utilisation of computed tomography for the fracture treatment has become common in the clinical practice. It would be helpful for orthopaedic clinicians, if they could get some additional information related to bone strength for better treatment planning. The aim of our study was to develop an automated system to segment the femoral neck region, extract the cortical and trabecular bone parameters, and assess the bone strength using an isotropic volume construction from clinical computed tomography images. The right hip computed tomography and right femur dual-energy X-ray absorptiometry measurements were taken from 50 south-Indian females aged 30-80 years. Each computed tomography image volume was re-constructed to form isotropic volumes. An automated system by incorporating active contour models was used to segment the neck region. A minimum distance boundary method was applied to isolate the cortical and trabecular bone components. The trabecular bone was enhanced and segmented using trabecular enrichment approach. The cortical and trabecular bone features were extracted and statistically compared with dual-energy X-ray absorptiometry measured femur neck bone mineral density. The extracted bone measures demonstrated a significant correlation with neck bone mineral density (r > 0.7, p computed tomography images scanned with low dose could eventually be helpful in osteoporosis diagnosis and its treatment planning. © IMechE 2016.

  12. Osteoarthritis of the hip

    International Nuclear Information System (INIS)

    Kokubo, Takashi; Takatori, Yoshio; Sasaki, Yasuhito

    1993-01-01

    Magnetic resonance imaging (MRI) is the modality of choice for evaluation of joint disease. Forty-one hips in 33 patients with osteoarthritis of the hip joint were examined by MRI and the features were analyzed. MR examinations were performed on a 1.5 T superconducting unit using the spin echo (SE) technique with short TR (600 ms)/short TE (23, 28, 35 ms) and short TR (600 ms)/long TE (70, 75 ms) sequences. MRI revealed deformity of the femoral head in all hips. Some outgrowths, which were isointense with normal bone marrow, were shown on the periphery of the femoral head in 22 hips (54%). These outgrowths represented marginal osteophytes. Short TE images showed hypointense areas, which varied in size, in the superior or supero-anterior aspect of the femoral head in all hips, and in the opposite position of the acetabulum in 38 hips (93%). These lesions showed a heterogenous signal with predominant low signal on long TE images. These images may indicate the presence of several components including subchondral cysts, bony sclerosis and fibrous tissue. In the joint space, areas of low signal intensity were shown on short TE images, which were high to intermediate signal intensity on long TE images in 16 hips (39%). These areas were presumably consistent with synovial proliferation, cartilageous hypertrophy or joint effusion. Both MR images revealed a mass locating just anterior to the femoral head in 2 hips (5%). The mass showed a low signal on short TE images and a high signal on long TE images, representing the distended iliopsoas bursa. (author)

  13. Athletic Hip Injuries.

    Science.gov (United States)

    Lynch, T Sean; Bedi, Asheesh; Larson, Christopher M

    2017-04-01

    Historically, athletic hip injuries have garnered little attention; however, these injuries account for approximately 6% of all sports injuries and their prevalence is increasing. At times, the diagnosis and management of hip injuries can be challenging and elusive for the team physician. Hip injuries are seen in high-level athletes who participate in cutting and pivoting sports that require rapid acceleration and deceleration. Described previously as the "sports hip triad," these injuries consist of adductor strains, osteitis pubis, athletic pubalgia, or core muscle injury, often with underlying range-of-motion limitations secondary to femoroacetabular impingement. These disorders can happen in isolation but frequently occur in combination. To add to the diagnostic challenge, numerous intra-articular disorders and extra-articular soft-tissue restraints about the hip can serve as pain generators, in addition to referred pain from the lumbar spine, bowel, bladder, and reproductive organs. Athletic hip conditions can be debilitating and often require a timely diagnosis to provide appropriate intervention.

  14. A comparison of two fixation methods for femoral trochanteric fractures: a new generation intramedullary system vs sliding hip screw.

    Science.gov (United States)

    Carulli, Christian; Piacentini, Federico; Paoli, Tommaso; Civinini, Roberto; Innocenti, Massimo

    2017-01-01

    Trochanteric fractures are frequent and generally associated with bone fragility. There is still debate on the best fixation device to treat stable or rather stable trochanteric fractures: we report our clinical and radiological results of fixation with Proximal Femoral Nail "antirotation" (PFNa) in a population of patients compared to a control group treated by Sliding Hip Screw (SHS). A prospective study was conducted in 71 consecutive patients treated by PFNa (group A), and 69 by a SHS (group B), with a mean age of 81.6 and 83.4 years respectively. Short Form 12 was administered to check postoperative results, and the following parameters were evaluated: range of motion, evaluation of pain, gait ability, X-rays, and Tip Apex Distance Index. A minimum follow-up was conducted in 128 patients: 66 subjects belonging to the PFNa group and 62 to the DHS group. All patients in the group A were able to reach partial or full weight-bearing on the operated leg before leaving the hospital. Forty-four patients (63.8%) of the group B were able to walk with partial weight-bearing before discharge. We recorded 17 complications with a final overall percentage of 17.2% on the overall study population with one single case of failure in both the two groups. A statistical significance (ptrochanteric fractures as well as DHS. The light superiority of PFNa may be principally related to its mechanical advantages.

  15. Material development in the SI sub 3 N sub 4 system using glass encapsulated Hip'ing

    Energy Technology Data Exchange (ETDEWEB)

    Corbin, N.D.; Sundberg, G.J.; Siebein, K.N.; Willkens, C.A.; Pujari, V.K.; Rossi, G.A.; Hansen, J.S.; Chang, C.L.; Hammarstrom, J.L.

    1992-04-01

    This report covers a two-year program to develop fully dense Si{sub 3}N{sub 4} matrix SiC whisker composites with enhanced properties over monolithic Si{sub 3}N{sub 4} materials. The primary goal was to develop a composite with a fracture toughness > 10 MPa{radical}m, capable of using high pressure glass encapsulated HIP'ing. Coating methods were developed to apply thin (<150nm) stoichiometric BN layers to SiC whiskers and also to apply a dual coating of SiC over carbon to the whiskers. Fracture toughness of the composites was determined to increase as the quantity of whiskers (or elongated grains) with their axis perpendicular to the crack plane increased. Of the interface compositions evaluated in this effort, carbon was determined to be the most effective for increasing toughness. The highest toughnesses (6.8--7.0 MPa{radical}m) were obtained with uniaxially aligned carbon coated whiskers. There was no evidence of the carbon coating compromising the oxidation resistance of the composites at 1370{degree}C.

  16. Establishing consensus on the definition of an isolated hip fracture for trauma system performance evaluation: A systematic review

    Directory of Open Access Journals (Sweden)

    Judith Tiao

    2014-01-01

    Full Text Available Background: Risk-adjusted mortality is widely used to benchmark trauma center care. Patients presenting with isolated hip fractures (IHFs are usually excluded from these evaluations. However, there is no standardized definition of an IHF. We aimed to evaluate whether there is consensus on the definition of an IHF used as an exclusion criterion in studies evaluating the performance of trauma centers in terms of mortality. Materials and Methods: We conducted a systematic review of observational studies. We searched the electronic databases MEDLINE, EMBASE, BIOSIS, The Cochrane Library, CINAHL, TRIP Database, and PROQUEST for cohort studies that presented data on mortality to assess the performance of trauma centers and excluded IHF. A standardized, piloted data abstraction form was used to extract data on study settings, IHF definitions and methodological quality of included studies. Consensus was considered to be reached if more than 50% of studies used the same definition of IHF. Results: We identified 8,506 studies of which 11 were eligible for inclusion. Only two studies (18% used the same definition of an IHF. Three (27% used a definition based on Abbreviated Injury Scale (AIS Codes and five (45% on International Classification of Diseases (ICD codes. Four (36% studies had inclusion criteria based on age, five (45% on secondary injuries, and four (36% on the mechanism of injury. Eight studies (73% had good overall methodological quality. Conclusions: We observed important heterogeneity in the definition of an IHF used as an exclusion criterion in studies evaluating the performance of trauma centers. Consensus on a standardized definition is needed to improve the validity of evaluations of the quality of trauma care.

  17. The Hyperflexible Hip

    Science.gov (United States)

    Weber, Alexander E.; Bedi, Asheesh; Tibor, Lisa M.; Zaltz, Ira; Larson, Christopher M.

    2015-01-01

    Context: Dance, gymnastics, figure skating, and competitive cheerleading require a high degree of hip range of motion. Athletes who participate in these sports use their hips in a mechanically complex manner. Evidence Acquisition: A search of the entire PubMed database (through December 2013) and additional searches of the reference lists of pertinent articles. Study Design: Systematic review. Level of Evidence: Level 3. Results: Whether innate or acquired, dancers and gymnasts have some hypermobility that allows their hips to be placed in potentially impinging or unstable positions required for their given activity. Such extremes of motion can result in both intra-articular and extra-articular impingement as well as compensatory osseous and muscular pathology. In addition, dancers and gymnasts are susceptible to impingement-induced instability. Dancers with innate generalized hyperlaxity are at increased risk of injury because of their activities and may require longer recovery times to return to play. Both nonoperative and operative treatments (arthroscopic and open) have an important role in returning flexibility athletes to their preoperative levels of sport and dance. Conclusion: Because of the extreme hip motion required and the compensatory soft tissue laxity in dancers and gymnasts, these athletes may develop instability, impingement, or combinations of both. This frequently occurs in the setting of subtle pathoanatomy or in patients with normal bony anatomy. With appropriate surgical indications and the correct operative technique, the treating surgeon can anticipate high levels of return to play for the gymnast and dancer with hip pain. PMID:26137181

  18. Complications in Hip Arthroscopy

    Science.gov (United States)

    Nakano, Naoki; Khanduja, Vikas

    2016-01-01

    Summary Background Recent developments in hip arthroscopic techniques and technology have made it possible in many cases to avoid open surgical dislocation for treating a variety of pathology in the hip. Although early reports suggest favourable results’ using hip arthroscopy and it has been shown to be a relatively safe procedure, complications do exist and can sometimes lead to significant morbidity. Methods This is a review article. The aim of this manuscript is to present the most frequent and/or serious complications that could occur at or following hip arthroscopy and some guidelines to avoid these complications. Conclusion Most complications of hip arthroscopy are minor or transient but serious complications can occur as well. A lot of complication e.g. acetabular labral puncture go unreported. Appropriate education and training, precise and meticulous surgical technique with correct instrumentation, the right indication in the right patient and adherence to advice from mentors and experienced colleagues are all essential factors for a successful outcome. Level of evidence: V. PMID:28066747

  19. Hip Replacement: MedlinePlus Health Topic

    Science.gov (United States)

    ... invasive hip replacement (Medical Encyclopedia) Also in Spanish Topic Image MedlinePlus Email Updates Get Hip Replacement updates ... replacement - precautions Minimally invasive hip replacement Related Health Topics Hip Injuries and Disorders National Institutes of Health ...

  20. Characteristics of children with hip displacement in cerebral palsy

    Directory of Open Access Journals (Sweden)

    Wagner Philippe

    2007-10-01

    Full Text Available Abstract Background Hip dislocation in children with cerebral palsy (CP is a common and severe problem. The dislocation can be avoided, by screening and preventive treatment of children with hips at risk. The aim of this study was to analyse the characteristics of children with CP who develop hip displacement, in order to optimise a hip surveillance programme. Methods In a total population of children with CP a standardised clinical and radiological follow-up of the hips was carried out as a part of a hip prevention programme. The present study is based on 212 children followed until 9–16 years of age. Results Of the 212 children, 38 (18% developed displacement with Migration Percentage (MP >40% and further 19 (9% MP between 33 and 39%. Mean age at first registration of hip displacement was 4 years, but some hips showed MP > 40% already at two years of age. The passive range of hip motion at the time of first registration of hip displacement did not differ significantly from the findings in hips without displacement. The risk of hip displacement varied according to CP-subtype, from 0% in children with pure ataxia to 79% in children with spastic tetraplegia. The risk of displacement (MP > 40% was directly related to the level of gross motor function, classified according to the gross motor function classification system, GMFCS, from 0% in children in GMFCS level I to 64% in GMFCS level V. Conclusion Hip displacement in CP often occurs already at 2–3 years of age. Range of motion is a poor indicator of hips at risk. Thus early identification and early radiographic examination of children at risk is of great importance. The risk of hip displacement varies according to both CP-subtype and GMFCS. It is sometimes not possible to determine subtype before 4 years of age, and at present several definitions and classification systems are used. GMFCS is valid and reliable from 2 years of age, and it is internationally accepted. We recommend a hip

  1. Sonography for hip joint effusion in adults with hip pain

    NARCIS (Netherlands)

    Bierma-Zeinstra, S. M.; Bohnen, A. M.; Verhaar, J. A.; Prins, A.; Ginai-Karamat, A. Z.; Laméris, J. S.

    2000-01-01

    To study the prevalence of ultrasonic hip joint effusion and its relation with clinical, radiological and laboratory (ESR) findings in adults with hip pain. Patients (n = 224) aged 50 years or older with hip pain, referred by the general practitioner for radiological investigation, underwent a

  2. Sonography for hip joint effusion in adults with hip pain

    NARCIS (Netherlands)

    S.M. Bierma-Zeinstra (Sita); A.M. Bohnen (Arthur); J.A.N. Verhaar (Jan); A. Prins (Ad); J.S. Lameris; A.Z. Ginai (Abida)

    2000-01-01

    textabstractOBJECTIVE: To study the prevalence of ultrasonic hip joint effusion and its relation with clinical, radiological and laboratory (ESR) findings in adults with hip pain. METHODS: Patients (n = 224) aged 50 years or older with hip pain, referred by the general

  3. The application of MR imaging in the detection of hip involvement in patients with ankylosing spondylitis

    International Nuclear Information System (INIS)

    Huang, Zhen-Guo; Zhang, Xue-Zhe; Hong, Wen; Wang, Guo-Chun; Zhou, Hui-Qiong; Lu, Xin; Wang, Wu

    2013-01-01

    Objective: To investigate the changes in hip MR imaging, evaluate the frequency of hip involvement and compare the value of clinical symptoms, radiographs, and MR imaging in the detection of hip involvement in patients with ankylosing spondylitis (AS). Methods: Anteroposterior radiographs of the pelvis, MR imaging of the hip and clinical evaluation were undertaken in 58 patients with definite AS. All patients were followed up 3 years. Annual radiographs and clinical evaluation were carried out. The imaging data were independently assessed by two experienced radiologists who were blinded to patient identity and clinical characteristics. Based on the Bath Ankylosing Spondylitis Radiology Hip Index (BASRI-hip) scoring system, BASRI-hip scores ≥2 were defined as radiological hip involvement. On MR imaging, both acute and chronic inflammatory changes were considered positive signs for hip involvement. Symptomatic hip involvement was defined as current or past pain or limitation of the hip movement. The statistical analysis was performed using the χ 2 test for comparison of sensitivity among clinical symptoms, radiographs, and MR imaging in the detection of hip involvement and the Student's t-test for comparison of disease duration between with and without hip involvement. A P value <0.05 was considered to be statistically significant. For interpreting MRI and radiographs, the percentage of agreement between the two assessors and the kappa coefficients were calculated. Results: On MR imaging, positive changes were detected in 86 (74.1%) hips among 116 hips in all 58 patients. Joint effusion was observed in 73 (62.9%) hips; 23 out of 27 patients who underwent fat-saturated contrast-enhanced T 1 -weighted sequences had abnormal synovial enhancement in bilateral hips. The other abnormal MR findings included subchondral bone marrow edema in 35 (30.2%) hips, enthesitis in 22 (19.0%) hips, fatty accumulation of the bone marrow in 28 (24.1%) hips, bone erosive

  4. Hip joint pathology

    DEFF Research Database (Denmark)

    Tijssen, M; van Cingel, R E H; de Visser, E

    2017-01-01

    The purpose of this retrospective cohort study was to (a) describe the clinical presentation of femoroacetabular impingement (FAI) and hip labral pathology; (b) describe the accuracy of patient history and physical tests for FAI and labral pathology as confirmed by hip arthroscopy. Patients (18......-65 years) were included if they were referred to a physical therapist to gather pre-operative data and were then diagnosed during arthroscopy. Results of pre-operative patient history and physical tests were collected and compared to arthroscopy. Data of 77 active patients (mean age: 37 years) were...

  5. X-Ray Exam: Hip

    Science.gov (United States)

    ... for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What It Is Why ... You Have Questions Print What It Is A hip X-ray is a safe and painless test ...

  6. Do diagnosis-related groups appropriately explain variations in costs and length of stay of hip replacement? A comparative assessment of DRG systems across 10 European countries.

    Science.gov (United States)

    Geissler, Alexander; Scheller-Kreinsen, David; Quentin, Wilm

    2012-08-01

    This paper assesses the variations in costs and length of stay for hip replacement cases in Austria, England, Estonia, Finland, France, Germany, Ireland, Poland, Spain and Sweden and examines the ability of national diagnosis-related group (DRG) systems to explain the variation in resource use against a set of patient characteristic and treatment specific variables. In total, 195,810 cases clustered in 712 hospitals were analyzed using OLS fixed effects models for cost data (n=125,698) and negative binominal models for length-of-stay data (n=70,112). The number of DRGs differs widely across the 10 European countries (range: 2-14). Underlying this wide range is a different use of classification variables, especially secondary diagnoses and treatment options are considered to a different extent. In six countries, a standard set of patient characteristics and treatment variables explain the variation in costs or length of stay better than the DRG variables. This raises questions about the adequacy of the countries' DRG system or the lack of specific criteria, which could be used as classification variables. Copyright © 2012 John Wiley & Sons, Ltd.

  7. Danish Hip Arthroscopy Registry

    DEFF Research Database (Denmark)

    Mygind-Klavsen, Bjarne; Lund, Bent; Nielsen, Torsten Grønbech

    2018-01-01

    PURPOSE: Predictors of outcome after femoroacetabular impingement (FAI) surgery are not well-documented. This study presents data from the Danish Hip Arthroscopy Registry (DHAR) for such analyses. The purpose of this study was to identify predictors of poor outcome after FAI surgery in a Danish FAI...

  8. Mechanical evaluation of hip pads to protect against fracture of elderly femurs in falls.

    Science.gov (United States)

    Tadano, Shigeru; Nakatsuchi, Hiroki; Goto, Naoko; Fujisaki, Kazuhiro; Nakatsuchi, Yukio

    2011-01-01

    Hip fracture in the aged easily occurs by falls and may cause these persons to become bedridden. Hip pads are effective in protecting hip fracture as they directly deflect and absorb the impact forces by falls. It is necessary for the material and the structure of hip pads to be designed to realize both high impact absorption and compliance (comfort during wearing). In this report, an impact testing system was developed to test the impact absorbing performance of hip pad with air cushions designed by the research group. The impact absorbing performance was evaluated by the impact load, collision time, and maximum load. To confirm the effectiveness in protecting against hip fracture, an impact force was applied to the greater trochanter of the human femur and the degree of fracture was measured by X-ray examination. As a result, the hip pad with air cushions had a high impact absorbing performance and was sufficiently effective to protect against hip fracture.

  9. The relationship between acute changes in the systemic inflammatory response and plasma ascorbic acid, alpha-tocopherol and lipid peroxidation after elective hip arthroplasty.

    Science.gov (United States)

    Conway, F J S; Talwar, D; McMillan, D C

    2015-08-01

    Vitamin C (ascorbic acid, AA) is a water soluble vitamin with many functions including antioxidative properties, haemostasis, hormone synthesis, collagen synthesis, carnitine synthesis, bile salt production and enhancing iron absorption. There is some evidence that there is a negative inverse relationship between plasma vitamin C concentration and the systemic inflammatory response as measured by C-reactive protein (CRP). The aim of the present study was to examine, in the context of a longitudinal study, the change in plasma concentrations of ascorbic acid (AA) and Vitamin E (α-tocopherol, AT) and their relationship to free radical damage during the evolution of the systemic inflammatory response. Venous blood samples were obtained pre-operatively and at 1, 2, 3 and 90 days post-operatively from 11 patients undergoing elective hip arthroplasty at Glasgow Royal Infirmary. AA, AT, cholesterol, MDA (marker of free radical damage), CRP and albumin were measured in plasma. Plasma AA fell significantly by 74% (P < 0.01), AT fell by 36% (P < 0.01), cholesterol by 40% (P < 0.01), MDA by 38% (P < 0.01), albumin by 29% (P < 0.01) and CRP increased significantly by 160 fold (P < 0.01) during the systemic inflammatory response. The fall in plasma AA remained significant when adjusted for albumin (P < 0.01). Plasma AT adjusted for cholesterol did not change significantly during the study period. The fall in plasma MDA remained significant when adjusted for albumin (P 0.01). At 3 months post-operatively, all measurements (including AA) except albumin had returned to baseline values. Plasma AA levels are unlikely to be a reliable measurement of Vitamin C where there is evidence of a systemic inflammatory response. The decrease in plasma AA concentration is likely to be secondary to increased consumption, increased usage neutralising free radicals, increased utilisation in supporting AT regeneration and increased urinary excretion. Copyright © 2014 Elsevier Ltd and European

  10. Studies on coagulation, fibrinolysis, kallikrein-kinin and complement activation in systemic and pulmonary circulation during hip arthroplasty with acrylic cement.

    Science.gov (United States)

    Dahl, O E; Molnar, I; Vinje, A; Rø, J S; Kierulf, P; Andersen, A B; Dalaker, K; Prydz, H

    1988-06-15

    This study was designed to evaluate the contribution of the plasma cascade systems to the cardiopulmonary complications, occasionally leading to sudden death during hip arthroplasty using acrylic cement. The intraoperative pattern following uneventful surgery was therefore investigated in 8 patients with osteoarthrosis with frequent sampling from the radial and pulmonary arteries. The following general findings emerged: A gradual consumption of coagulation factors (platelets, fibrinogen, factor VII, antithrombin III), fibrinolytic components (plasminogen, alpha-2-antiplasmin), kallikrein-kinin factors (prekallikrein, kallikrein inhibitor) and complement factors (C3c, C4) was observed. Some intrapulmonary proteolytic inhibition was noticed as evidenced by lower arterial than mixed venous blood levels of alpha-2-antiplasmin and kallikrein inhibitor. Insignificant changes occurred for factor VII-phospholipid complex. A rapid, massive and transient increase in fibrinopeptide A (FPA) values in the radial artery, as opposed to the moderate increase in the pulmonary artery, was found immediately after reaming and broaching of bone. This probably reflected intrapulmonary fibrinogen to fibrin conversion, reaching a maximum 15-20 minutes before the femoral implantation. As estimated from the FPA arterial peak values and the fall in fibrinogen concentrations, approximately 5-10% of the circulating fibrinogen molecules were devoided of FPA during this intraoperative phase. The marked a-v difference in FPA level supports earlier findings of intrapulmonary fibrin formation and deposition. This process, however preceded the critical period of cardiorespiratory collapse (CRC) by at least 15 minutes, and may thus predispose to this complication.

  11. Geometry Modeling Program Implementation of Human Hip Tissue

    Directory of Open Access Journals (Sweden)

    WANG Mo-nan

    2017-10-01

    Full Text Available Abstract:Aiming to design a simulate software of human tissue modeling and analysis,Visual Studio 2010 is selected as a development tool to develop a 3 D reconstruction software of human tissue with language C++.It can be used alone. It also can be a module of the virtual surgery systems. The system includes medical image segmentation modules and 3 D reconstruction modules,and can realize the model visualization. This software system has been used to reconstruct hip muscles,femur and hip bone accurately. The results show these geometry models can simulate the structure of hip tissues.

  12. Geometry Modeling Program Implementation of Human Hip Tissue

    Directory of Open Access Journals (Sweden)

    WANG Monan

    2017-04-01

    Full Text Available Aiming to design a simulate software of human tissue modeling and analysis,Visual Studio 2010 is selected as a development tool to develop a 3 D reconstruction software of human tissue with language C++.It can be used alone. It also can be a module of the virtual surgery systems. The system includes medical image segmentation modules and 3 D reconstruction modules,and can realize the model visualization. This software system has been used to reconstruct hip muscles,femur and hip bone accurately. The results show these geometry models can simulate the structure of hip tissues.

  13. Avascular necrosis of the hip

    International Nuclear Information System (INIS)

    Lang, P.; Genant, H.K.; Lindquist, T.; Chafetz, N.; Steiger, P.; Sanny, J.; Rhodes, M.L.; Rothman, S.L.G.; Delamarter, R.; Kilgus, D.

    1988-01-01

    T1-weighted (repetition time [TR] = 450 msec, echo time [TE] = 20 msec), T2-weighted (TR = 1,800 msec, TE = 20 and 80 msec), and T2*-weighted gradient-echo gradient recalled acquisition in a steady state, TR = 70 msec, TE = 30 msec, theta = 15 0 ) MR images (General Electric Signa, 1.5 T) were generated in 11 patients with avascular necrosis of the hip. Three-dimensional MR image reconstruction was performed on an independent imaging system (IIS, Dimensional Medicine Inc). Pelvic and femoral bone contours were computed based on either the T1-weighted or the T2*-weighted images. Three-dimensional displays of necrotic zones and areas of granulation tissue were computed on the basis of the T2-weighted images. The tissues were simultaneously displayed in the three-dimensional images using different colors and transparencies. The three-dimensional MR images generated demonstrated the extent of the necrotic zone and adjacent granulation tissue and their position relative to the weight-bearing surface. They may soon prove to be useful in preoperative planning and intraoperative localization of complex surgical interventions in avascular necrosis of the hip

  14. Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Helen; Cahir, John G.; Goodwin, Richard W. [Norfolk and Norwich University Hospital, Department of Radiology, Norwich, Norfolk (United Kingdom); Toms, Andoni Paul [Norfolk and Norwich University Hospital, Department of Radiology, Norwich, Norfolk (United Kingdom); Norwich Radiology Academy, Norwich (United Kingdom); Wimhurst, James; Nolan, John F. [Norfolk and Norwich University Hospital, Department of Orthopaedics, Norwich, Norfolk (United Kingdom)

    2011-03-15

    Metal-on-metal (MoM) soft tissue reactions or aseptic lymphocytic vasculitis-associated lesions (ALVAL) are being recognised using metal artefact reduction (MAR) MR with increasing frequency following the advent of second generation metal-on-metal bearings, but there is no standardised technique for reporting of MR appearances in this disease. The aim of this study was to measure the reliability of a grading system designed for scoring the severity of MoM disease on MRI. MRI examinations of 73 hips in 59 patients were retrospectively selected and then anonymised, randomised and reviewed by three independent observers (musculoskeletal radiologists). Each MR examination was scored as either A: normal, B: infection, C1: mild MoM disease, C2: moderate MoM disease or C3: severe MoM disease according to pre-defined criteria. Kappa correlation statistics were used to compare the observations. There was substantial agreement among all three observers; the correlation coefficient between the two most experienced observers was {kappa} = 0.78 [95% confidence intervals (CI): 0.68-0.88] and when compared with the least experienced observer coefficients were {kappa} = 0.69 (95% CI: 0.57-0.80) and {kappa} = 0.66 (95% CI: 0.54-0.78). The strongest correlation occurred for grades A, C2 and C3. The weakest correlations occurred for grades B and C1. The grading system described in this study is reliable for evaluating ALVAL in MoM prostheses using MR but is limited in differentiating mild disease from infection. (orig.)

  15. A new system of computer-assisted navigation leading to reduction in operating time in uncemented total hip replacement in a matched population.

    Science.gov (United States)

    Chaudhry, Fouad A; Ismail, Sanaa Z; Davis, Edward T

    2018-05-01

    Computer-assisted navigation techniques are used to optimise component placement and alignment in total hip replacement. It has developed in the last 10 years but despite its advantages only 0.3% of all total hip replacements in England and Wales are done using computer navigation. One of the reasons for this is that computer-assisted technology increases operative time. A new method of pelvic registration has been developed without the need to register the anterior pelvic plane (BrainLab hip 6.0) which has shown to improve the accuracy of THR. The purpose of this study was to find out if the new method reduces the operating time. This was a retrospective analysis of comparing operating time in computer navigated primary uncemented total hip replacement using two methods of registration. Group 1 included 128 cases that were performed using BrainLab versions 2.1-5.1. This version relied on the acquisition of the anterior pelvic plane for registration. Group 2 included 128 cases that were performed using the newest navigation software, BrainLab hip 6.0 (registration possible with the patient in the lateral decubitus position). The operating time was 65.79 (40-98) minutes using the old method of registration and was 50.87 (33-74) minutes using the new method of registration. This difference was statistically significant. The body mass index (BMI) was comparable in both groups. The study supports the use of new method of registration in improving the operating time in computer navigated primary uncemented total hip replacements.

  16. Revision hip preservation surgery with hip arthroscopy: clinical outcomes.

    Science.gov (United States)

    Domb, Benjamin G; Stake, Christine E; Lindner, Dror; El-Bitar, Youseff; Jackson, Timothy J

    2014-05-01

    To analyze and report the clinical outcomes of a cohort of patients who underwent revision hip preservation with arthroscopy and determine predictors of positive and negative outcomes. During the study period from April 2008 to December 2010, all patients who underwent revision hip preservation with arthroscopy were included. This included patients who had previous open surgery and underwent revision with arthroscopy. Patient-reported outcome (PRO) scores were obtained preoperatively and at 3-month, 1-year, 2-year, and 3-year follow-up time points. Any revision surgeries and conversions to total hip arthroplasty were noted. A multiple regression analysis was performed to look for positive and negative predictive factors for improvement in PROs after revision hip arthroscopy. Forty-seven hips in 43 patients had completed 2 years' follow-up or needed total hip arthroplasty. The mean length of follow-up was 29 months (range, 24 to 47 months). Of the hips, 31 (66%) had either unaddressed or incompletely treated femoroacetabular impingement. There was a significant improvement in all PRO scores at a mean of 29 months after revision (P arthroscopy can achieve moderately successful outcomes and remains a viable treatment strategy after failed primary hip preservation surgery. Preoperative predictors of success after revision hip arthroscopy include segmental labral defects, unaddressed or incompletely addressed femoroacetabular impingement, heterotopic ossification, and previous open surgery. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Synovial plicae of the hip: evaluation using MR arthrography in patients with hip pain

    International Nuclear Information System (INIS)

    Bencardino, Jenny T.; La Rocca Vieira, Renata; Kassarjian, Ara; Schwartz, Richard; Mellado, Jose M.; Kocher, Mininder

    2011-01-01

    The appearance and distribution of the intra-articular plicae of the hip have been addressed in few reports in the anatomic and radiological literature. This study aims to determine the prevalence of visible synovial hip plicae using MR arthrography and to measure the association of visible synovial hip plicae with MR arthrographic diagnosis of labral tears, femoroacetabular impingement, and osteoarthritis. Following institutional review board approval, 63 direct MR arthrographic examinations of the hip in 61 patients with a clinical history of hip pain were retrospectively reviewed by two experienced musculoskeletal radiologists in consensus. The following variables were measured using a binary system (0 = absent; 1 = present): labral plica, neck plica, ligamental plica, labral tear, femoroacetabular impingement, and osteoarthritis. The surgical reports and arthroscopic images of 10 patients were reviewed. Statistical analysis was performed using the Fisher's exact test. In all 63 cases at least one plica was visualized on MR-arthrographic images. Labral, neck, and ligamental plicae were found with a prevalence of 76, 97, and 78%, respectively. There was no statistically significant association between the presence of labral tears, femoroacetabular impingement, and osteoarthritis among patients with visible labral, neck, and ligamental plicae. The prevalence of labral tears, femoroacetabular impingement, and osteoarthritis in our patient population was 79, 28, and 28%, respectively. The presence of intra-articular plicae was the only MR-arthrographic finding in 5 of our 63 symptomatic cases. Visible labral, neck, and/or ligamental plicae are highly prevalent on MR-arthrographic images of the hip performed in the setting of hip pain. There was no statistically significant association between the presence of labral tears, femoroacetabular impingement, and osteoarthritis and visible labral, neck, and ligamental plicae. (orig.)

  18. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic cemented or... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted...

  19. 21 CFR 888.3400 - Hip joint femoral (hemi-hip) metallic resurfacing prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic resurfacing... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3400 Hip joint femoral (hemi-hip) metallic resurfacing prosthesis. (a) Identification. A hip joint femoral (hemi-hip...

  20. 21 CFR 888.3370 - Hip joint (hemi-hip) acetabular metal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint (hemi-hip) acetabular metal cemented... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3370 Hip joint (hemi-hip) acetabular metal cemented prosthesis. (a) Identification. A hip joint (hemi-hip) acetabular...

  1. Social inequality and hip fracture

    DEFF Research Database (Denmark)

    Harvey, N. C.; Hansen, L.; Judge, A.

    2015-01-01

    Social inequality appears to be increasing in many countries. We explored whether risk of hip fracture was associated with markers of inequality and whether these relationships changed with time, using data from Danish Health Registries. Methods: All patients 60 years or older with a primary hip...... fracture (ICD10: S720, S721, S722 and S729) were identified from 1 January 1995 to 31 December 2011. Hip fracture patients were matched 1:1 on age, gender and year of fracture to a non-hip fracture control. An individual's education attainment was defined as basic, secondary or higher, and their income...

  2. Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty.

    Science.gov (United States)

    Czech, Szymon; Hermanson, Jacek; Rodak, Piotr; Stołtny, Tomasz; Rodak, Łukasz; Kasperczyk, Sławomir; Koczy, Bogdan; Mielnik, Michał

    2017-12-01

    An adequate level of physical activity has a substantial effect on both mental and physical human health. Physical activity is largely dependent on the function of the musculoskeletal and articular system. One of the most frequent diseases of this system is degenerative joint disease. Due to the changing and more demanding lifestyles and patients' willingness to be involved in sports activity, the expectations of hip joint arthroplasty are becoming increasingly high. Alleviating pain ceases to be the only reason for which patients choose surgical interventions, while the expectations often include involvement in various sports. Only few studies contain recommendations concerning the frequency, type and intensity of sports activity which are acceptable after hip joint arthroplasty. The aim of the study was to evaluate function and physical activity of people following cementless short-stem hip joint arthroplasty in the observation of at least five years. The study group comprised 106 patients who underwent total hip arthroplasty due to degenerative joint diseases, chosen according to inclusion criteria. Patients underwent routine physical examinations following the Harris Hip Score protocol, responded to the UCLA scale and questionnaires concerning pre-surgical and current physical activity. Our results demonstrated that hip joint arthroplasty in people suffering from degenerative joint diseases has a beneficial effect on their level of functioning and physical activity. Although physical activity and the level of functioning obviously reduced as a person aged, the level of physical activity continued to be very high in both groups, with function of the hip joint evaluated as very good.

  3. Interobserver and intraobserver reliability and validity of the Vancouver classification system of periprosthetic femoral fractures after hip arthroplasty.

    LENUS (Irish Health Repository)

    Naqvi, Gohar A

    2012-06-01

    The Vancouver classification system of periprosthetic fractures has been revalidated in this study, using the radiographs of 45 patients. Three consultants and 3 trainees reviewed the radiographs independently, on 2 separate occasions, at least 2 weeks apart. Interobserver and intraobserver agreement and validity were analyzed, using weighted κ statistics. The mean κ value for interobserver agreement was found to be 0.69 (0.63-0.72) for consultants and 0.61 (0.56-0.65) for the trainees, both representing substantial agreement. Intraobserver κ values ranged from 0.74 to 0.90, showing substantial agreement. Validity analysis of 37 type B cases revealed 81% agreement within B1, B2, and B3 subgroups with a κ value of 0.68 (substantial agreement). This study has reconfirmed the reliability and validity of the Vancouver classification while it also emphasizes the intraoperative assessment of implant stability.

  4. Pain in the hip joint

    Directory of Open Access Journals (Sweden)

    Yuri Aleksandrovich Olyunin

    2013-01-01

    Full Text Available Pathological changes that develop in the hip joints (HJ have different origins and mechanisms of development, but their main manifestation is pain. The nature of this pain cannot be well established on frequent occasions. The English-language medical literature currently classifies such disorders as greater trochanter pain syndrome (GTPS. Its major signs are chronic pain and local palpatory tenderness in the outer part of HJ. The development of GTPS may be associated with inflammation of the synovial bursae situated in the greater tronchanter, as well as with tendinitis, myorrhexis, iliotibial band syndrome, and other local changes in the adjacent tissues or with systemic diseases. So GTPS may be characterized as regional pain syndrome that frequently mimics pain induced by different diseases, including myofascial pain syndrome, osteoarthrosis, spinal diseases, etc.

  5. Gluteal tendinopathy and hip osteoarthritis: Different pathologies, different hip biomechanics.

    Science.gov (United States)

    Allison, Kim; Hall, Michelle; Hodges, Paul W; Wrigley, Tim V; Vicenzino, Bill; Pua, Yong-Hao; Metcalf, Ben; Grimaldi, Alison; Bennell, Kim L

    2018-03-01

    Gluteal tendinopathy (GT) and hip osteoarthritis (OA) are the most common causes of hip pain and associated disability in older adults. Pain and altered walking biomechanics are common to both conditions. This study aimed to compare three-dimensional walking biomechanics between individuals with unilateral, symptomatic GT and HOA. Sixty individuals with symptomatic unilateral GT confirmed by magnetic-resonance-imaging and 73 individuals with symptomatic unilateral HOA (Kellgren-Lawrence Grade ≥ 2) underwent three-dimensional gait analysis. Maximum and minimum values of the external sagittal hip moment, the first peak, second peak and mid-stance minimum of the hip adduction moment (HAM), sagittal plane hip excursion and hip joint angles, pelvic obliquity and trunk lean, at the three HAM time points during stance phase of walking were compared between groups. Compared to individuals with HOA, those with GT exhibited a greater hip peak extension moment (P < 0.001) and greater HAM throughout the stance phase of walking (P = 0.01-P < 0.001), greater hip adduction (P < 0.001) and internal rotation (P < 0.01-P < 0.001) angles and lower hip flexion angles and excursion (P = 0.02 - P < 0.001). Individuals with HOA exhibited a greater forward trunk lean (P ≤ 0.001) throughout stance, and greater ipsilateral trunk lean in the frontal plane (P < 0.001) than those with GT. Despite presence of pain in both conditions, hip kinematics and kinetics differ between individuals with symptomatic unilateral GT and those with symptomatic unilateral HOA. These condition-specific impairments may be targets for optimization of management of HOA and GT. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Hip-Hop Education Resources

    Science.gov (United States)

    Hall, Marcella Runell

    2009-01-01

    Hip-hop music and culture are often cited as being public pedagogy, meaning the music itself has intrinsic educational value. Non-profit organizations and individual educators have graciously taken the lead in utilizing hip-hop to educate. As the academy continues to debate its effectiveness, teachers and community organizers are moving forward.…

  7. Total hip arthroplasty in Denmark

    DEFF Research Database (Denmark)

    Pedersen, Alma Becic; Johnsen, Søren Paaske; Overgaard, Søren

    2005-01-01

    The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs.......The annual number of total hip arthroplasties (THA) has increased in Denmark over the past 15 years. There is, however, limited detailed data available on the incidence of THAs....

  8. The Danish Hip Arthroplasty Register

    DEFF Research Database (Denmark)

    Gundtoft, Per Hviid; Varnum, Claus; Pedersen, Alma Becic

    2016-01-01

    AIM OF DATABASE: The aim of the Danish Hip Arthroplasty Register (DHR) is to continuously monitor and improve the quality of treatment of primary and revision total hip arthroplasty (THA) in Denmark. STUDY POPULATION: The DHR is a Danish nationwide arthroplasty register established in January 1995...

  9. Hip sonography in the newborn

    International Nuclear Information System (INIS)

    Riboni, G.; Serantoni, S.; De Simoni, M.; Bascape', P.; Facchini, R.; Pirovano, G.

    1991-01-01

    The authors report the data relative to 1507 cases studied with clinical and US examinations, in the neonatal period, in order to exclude hip dysplasia dislocation. US examination was carried out according to Graf's technique and the newborns were classified according to US hip type, to clinical examination and to possible risk factors. The patients were included in a protocol including orthopedic and US controls. Seventeen treated infants were considered as pathologic. Ten of them had IIc or D hips ar birth; the other 7, with IIa hips at birth, presented a X-ray pathologic hip after the 4th months of life. At about one year of age all infants could normally walk, excpet for one who was being treated with herness. No statistically significant differences were observed between the number of pathologic infants in the risk group (1.7%) and that in the no-risk group (0.8%). Clinical examination of the newborn has low sensitivity in detecting pathologic hips. On the basis of their results, thw authors belive US examination of the newborn to be a valuable screening method to diagnose hip dysplasia/dislocation. Moreover, Graf's morphologic method is the best one for US screening of the hip in the neonatal period

  10. Clinical Evaluation of Fused/Ankylosed Hip with Severe Flexion Deformity after Conversion to Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Saroj Kumar Suwal

    2016-06-01

    Conclusions: THA is an effective treatment for ankylosed hip with severe flexion deformity although complications are noted more than routine hip arthroplasties. Keywords: ankylosed hip; fused hip; severe flexion deformity; total hip arthroplasty. | PubMed

  11. Grading and quantification of hip osteoarthritis severity by analyzing the spectral energy distribution of radiographic hip joint space

    International Nuclear Information System (INIS)

    Boniatis, I; Costaridou, L; Panayiotakis, G; Panagiotopoulos, E

    2009-01-01

    An image analysis system is proposed for the assessment of hip osteoarthritis (OA) severity. Sixty four hips (18 normal, 46 osteoarthritic), corresponding to 32 patients of unilateral or bilateral hip OA were studied. Employing custom developed software, 64 Region Of Interest (ROI) images of Hip Joint Spaces (HJSs) were delineated on patients' digitized radiographs. The Fourier spectrum of each HJS-ROI was computed and expressed in polar coordinates. Spectral signatures, quantifying the radial and angular distribution of HJS spectral energy were formed. Signature descriptors were generated and utilized in the design of a two-level hierarchical decision tree, used for the grading of the severity of the disease. Accordingly, at Level 1, implemented by a multiple classifier system, the discrimination between normal and osteoarthritic hips was performed. At Level 2, the hips that had been successfully characterized as osteoarthritic at Level 1, were further characterized as of 'Mild / Moderate' or 'Severe' OA, by the Bayes classifier. A signature descriptors based regression model was designed, so as to quantify OA-severity. The system graded OA reliably, given that the accomplished classification accuracies for Level 1 and Level 2 were 98.4% and 100%, respectively. OA-severity values, expressed by HJS-narrowing, correlated highly (r = 0.9, p < 0.001) with values predicted by the model. The system may contribute to OA-patient management.

  12. Acetabular component positioning in total hip arthroplasty with and without a computer-assisted system: a prospective, randomized and controlled study.

    Science.gov (United States)

    Gurgel, Henrique M C; Croci, Alberto T; Cabrita, Henrique A B A; Vicente, José Ricardo N; Leonhardt, Marcos C; Rodrigues, João Carlos

    2014-01-01

    In a study of the acetabular component in total hip arthroplasty, 20 hips were operated on using imageless navigation and 20 hips were operated on using the conventional method. The correct position of the acetabular component was evaluated with computed tomography, measuring the operative anteversion and the operative inclination and determining the cases inside Lewinnek's safe zone. The results were similar in all the analyses: a mean anteversion of 17.4° in the navigated group and 14.5° in the control group (P=.215); a mean inclination of 41.7° and 42.2° (P=.633); a mean deviation from the desired anteversion (15°) of 5.5° and 6.6° (P=.429); a mean deviation from the desired inclination of 3° and 3.2° (P=.783); and location inside the safe zone of 90% and 80% (P=.661). The acetabular component position's tomography analyses were similar whether using the imageless navigation or performing it conventionally. Published by Elsevier Inc.

  13. Evaluating healthcare resource utilization and outcomes for surgical hip dislocation and hip arthroscopy for femoroacetabular impingement.

    Science.gov (United States)

    de Sa, Darren; Horner, Nolan S; MacDonald, Austin; Simunovic, Nicole; Slobogean, Gerard; Philippon, Marc J; Belzile, Etienne L; Karlsson, Jon; Ayeni, Olufemi R

    2016-12-01

    Surgical hip dislocation (SHD) and hip arthroscopy are surgical methods used to correct deformity associated with femoroacetabular impingement (FAI). Though both of these approaches appear to benefit patients, no studies exist comparing healthcare resource utilization of the two surgical approaches. This systematic review examines the literature and the records of two surgeons to evaluate the resource utilization associated with treating symptomatic FAI via these two methods. EMBASE, MEDLINE and PubMed were searched for relevant articles. The articles were systematically screened, and data was abstracted in duplicate. To further supplement resource utilization data, a retrospective chart review of two surgeon's patient data (one using SHD and another using an arthroscopic approach) was completed. Experts in pharmacy, physiotherapy, radiology, anaesthesia, physiatry and the local hospital finance department were also consulted. There were 52 studies included with a total of 460 patients (535 hips) and 3886 patients (4147 hips) who underwent SHD and arthroscopic surgery for FAI, respectively. Regardless of approach, most patients treated for symptomatic FAI improved across various outcomes measures with low complication rates. Surgical time across all approaches was similar, averaging 118 ± 2 min. On a per patient basis, hip arthroscopy ($10,976) uses approximately 41 % of the resources of SHD ($24,379). There were no significant differences in outcomes for FAI treated with SHD or arthroscopy. However, with regard to healthcare resource utilization based on the OHIP healthcare system, hip arthroscopy uses substantially less resources than SHD within the first post-operative year. Systematic Review of Level IV Studies, Level IV.

  14. Muscle atrophy and metal-on-metal hip implants: a serial MRI study of 74 hips.

    Science.gov (United States)

    Berber, Reshid; Khoo, Michael; Cook, Erica; Guppy, Andrew; Hua, Jia; Miles, Jonathan; Carrington, Richard; Skinner, John; Hart, Alister

    2015-06-01

    Muscle atrophy is seen in patients with metal-on-metal (MOM) hip implants, probably because of inflammatory destruction of the musculo-tendon junction. However, like pseudotumors, it is unclear when atrophy occurs and whether it progresses with time. Our objective was to determine whether muscle atrophy associated with MOM hip implants progresses with time. We retrospectively reviewed 74 hips in 56 patients (32 of them women) using serial MRI. Median age was 59 (23-83) years. The median time post-implantation was 83 (35-142) months, and the median interval between scans was 11 months. Hip muscles were scored using the Pfirrmann system. The mean scores for muscle atrophy were compared between the first and second MRI scans. Blood cobalt and chromium concentrations were determined. The median blood cobalt was 6.84 (0.24-90) ppb and median chromium level was 4.42 (0.20-45) ppb. The median Oxford hip score was 34 (5-48). The change in the gluteus minimus mean atrophy score between first and second MRI was 0.12 (p = 0.002). Mean change in the gluteus medius posterior portion (unaffected by surgical approach) was 0.08 (p = 0.01) and mean change in the inferior portion was 0.10 (p = 0.05). Mean pseudotumor grade increased by 0.18 (p = 0.02). Worsening muscle atrophy and worsening pseudotumor grade occur over a 1-year period in a substantial proportion of patients with MOM hip implants. Serial MRI helps to identify those patients who are at risk of developing worsening soft-tissue pathology. These patients should be considered for revision surgery before irreversible muscle destruction occurs.

  15. The pelvis and hips

    International Nuclear Information System (INIS)

    Berquist, T.H.; Coventry, M.B.

    1985-01-01

    Radiographic evaluation of joint replacements requires close communication between the radiologist and referring physician. Routine films, radioisotope scans, and subtraction arthrography (including aspiration and injection of the pseudocapsule) may be indicated in different clinical situations. This paper summarizes the accuracy of these modalities. Most patients present with pain. One must exclude loosening, infection, and other problems. The arthrogram is most useful in defining anatomy and most causes of hip pain. Culture studies and diagnostic injections add to the versatility of subtraction arthrography and increase its accuracy. If plain films are negative, a Tc-99m scan can be obtained. If this is negative, loosening is unlikely. If pain persists or if the scan is positive, an arthrogram should be performed. Pain may be secondary to bursitis rather than loosening, and the arthrogram will assist in diagnosis and treatment. When films suggest loosening, arthrography is the procedure of choice to confirm the diagnosis and to exclude infection

  16. Hip complications following chemoradiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, P.J.; Sebag Montefiore, D.J.; Arnott, S.J. [Saint Bartholomew`s Hospital, London (United Kingdom)

    1995-12-01

    Chemoradiotherapy protocols are a recent development in the management of tumours where preservation of organ function is important. It is now recognized that such combined treatment may produce adverse effects below the accepted dose thresholds for either modality. This enhancement of toxicity is generally thought to reflect depletion of stem cells within the tissue concerned. We report four patients who have developed avascular necrosis or fractures of the hip following chemoradiotherapy for carcinoma of the vulva or anus. These complications developed after a radiation dose of 4500 cGy in 20 fractions. The possible role of cytotoxic agents in sensitizing bone to radiation damage is discussed, and a novel mechanism is proposed to account for this phenomenon. (author).

  17. Hip complications following chemoradiotherapy

    International Nuclear Information System (INIS)

    Jenkins, P.J.; Sebag Montefiore, D.J.; Arnott, S.J.

    1995-01-01

    Chemoradiotherapy protocols are a recent development in the management of tumours where preservation of organ function is important. It is now recognized that such combined treatment may produce adverse effects below the accepted dose thresholds for either modality. This enhancement of toxicity is generally thought to reflect depletion of stem cells within the tissue concerned. We report four patients who have developed avascular necrosis or fractures of the hip following chemoradiotherapy for carcinoma of the vulva or anus. These complications developed after a radiation dose of 4500 cGy in 20 fractions. The possible role of cytotoxic agents in sensitizing bone to radiation damage is discussed, and a novel mechanism is proposed to account for this phenomenon. (author)

  18. Chronic infections in hip arthroplasties

    DEFF Research Database (Denmark)

    Lange, Jeppe; Troelsen, Anders; Thomsen, Reimar W

    2012-01-01

    Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two-stage revisi......Two-stage revision is regarded by many as the best treatment of chronic infection in hip arthroplasties. Some international reports, however, have advocated one-stage revision. No systematic review or meta-analysis has ever compared the risk of reinfection following one-stage and two......-stage revisions for chronic infection in hip arthroplasties....

  19. Traumatic injuries of the hip.

    LENUS (Irish Health Repository)

    Marshall, Nina

    2009-11-01

    Traumatic lesions of the hip in athletes may be clinically challenging because of the overlap in clinical presentation due to differing pathologies and the presence of multiple injuries. Imaging of the hip in the athlete has undergone a recent resurgence of interest and understanding related to the increasing accessibility and use of hip arthroscopy, which expands the treatment options available for intra-articular pathology. MR imaging and MR arthrography have a unique role in diagnosis of these pathologies, guiding the surgeon, arthroscopist, and referring clinician in their management of bony and soft tissue injury.

  20. Primary total hip replacement versus hip resurfacing - hospital considerations.

    Science.gov (United States)

    Ward, William G; Carter, Christina J; Barone, Marisa; Jinnah, Riyaz

    2011-01-01

    Multiple factors regarding surgical procedures and patient selection affect hospital staffing needs as well as hospital revenues. In order to better understand the potential impact on hospitals that hip arthroplasty device selection (standard total hip arthroplasty vs. resurfacing) creates, a review of all primary hip arthroplasties performed at one institution was designed to identify factors that impacted hospital staffing needs and revenue generation. All primary hip arthroplasties undertaken over three fiscal years (2008 to 2010) were reviewed, utilizing only hospital business office data and medical records data that had been previously extracted prior for billing purposes. Analysis confirmed differing demographics for two hip arthroplasty populations, with the resurfacing patients (compared to the conventional total hip arthroplasty population) consisting of younger patients (mean age, 50 vs. 61 years), who were more often male (75% vs. 45%), were more likely to have osteoarthritis as their primary diagnosis (83 vs. 67%) and were more often covered by managed care or commercial insurance (83 vs. 34%). They also had shorter hospital stays (mean length of stay, 2.3 vs. 4.1 days) and consequently provided a more favorable financial revenue stream to the hospital on a per patient basis. Several trends appeared during the study periods. There was a steady increase in all procedures in all groups except for the resurfacings, which decreased 26% in males and 53% in females between 2009 and 2010. Differences were observed in the demographics of patients presenting for resurfacing, compared to those presenting for conventional total hip arthroplasty. In addition to the revenue stream considerations, institutions undertaking a resurfacing program must commit the resources and planning in order to rehabilitate these patients more expeditiously than is usually required with conventional hip arthroplasty patients.

  1. [Bone surgery for unstable hips in patients with cerebral palsy].

    Science.gov (United States)

    Poul, J; Pesl, M; Pokorná, M

    2004-01-01

    The aim of this retrospective study was to compare the efficacy of femoral osteotomy alone with that of osteotomy combined with an acetabular procedure in patients with unstable hips due to spastic cerebral palsy. Sixty-one hip joints in 50 patients who had shown distinct subluxation or dislocation of the joint were operated on. Eleven patients underwent bilateral surgery. Before bone surgery, soft-tissue release involving both the flexors and adductors was performed on 19 hips. Femoral osteotomy alone was performed on 29 hip joints and combined femoral and pelvic osteotomy was carried out on 32 joints.Twelve resections of the proximal femur in seven patients were evaluated as a separate group. All treated hip joints were assessed by clinical and radiographic examination at a follow-up of more than 5 years. The skiagraphs taken in a strictly neutral position of the lower limbs before surgery and at the final examination were evaluated on the basis of Reimers's migration index and Wiberg's centre-edge angle. The locomotor abilities of each child were categorized according to the Vojta scoring system for locomotor development. The range of motion in the treated hip joint was assessed using the standard S. F. T. R. method. The results obtained were statistically analyzed by the Kruskal- Wallis, one-way ANOVA test. A comparison of the results of femoral osteotomy alone with those of combined femoral and pelvic osteotomy showed that the post-operative values of the migration index and centre-edge angle, as compared with the pre-operative ones, were statistically higher (pVojta rating system. There was no change in the range of motion in the treated hip joints after the operation. In 28, out of the 32 joints treated by combined femoral and pelvic osteotomy, Salter osteotomy was performed and it showed a high efficacy in providing hip joint stability. The main emphasis during surgery was placed on the maximum acetabular rotation laterally. Femoral osteotomy alone was less

  2. Friction measurement in a hip wear simulator.

    Science.gov (United States)

    Saikko, Vesa

    2016-05-01

    A torque measurement system was added to a widely used hip wear simulator, the biaxial rocking motion device. With the rotary transducer, the frictional torque about the drive axis of the biaxial rocking motion mechanism was measured. The principle of measuring the torque about the vertical axis above the prosthetic joint, used earlier in commercial biaxial rocking motion simulators, was shown to sense only a minor part of the total frictional torque. With the present method, the total frictional torque of the prosthetic hip was measured. This was shown to consist of the torques about the vertical axis above the joint and about the leaning axis. Femoral heads made from different materials were run against conventional and crosslinked polyethylene acetabular cups in serum lubrication. Regarding the femoral head material and the type of polyethylene, there were no categorical differences in frictional torque with the exception of zirconia heads, with which the lowest values were obtained. Diamond-like carbon coating of the CoCr femoral head did not reduce friction. The friction factor was found to always decrease with increasing load. High wear could increase the frictional torque by 75%. With the present system, friction can be continuously recorded during long wear tests, so the effect of wear on friction with different prosthetic hips can be evaluated. © IMechE 2016.

  3. A three-dimensional finite element model for biomechanical analysis of the hip.

    Science.gov (United States)

    Chen, Guang-Xing; Yang, Liu; Li, Kai; He, Rui; Yang, Bin; Zhan, Yan; Wang, Zhi-Jun; Yu, Bing-Nin; Jian, Zhe

    2013-11-01

    The objective of this study was to construct a three-dimensional (3D) finite element model of the hip. The images of the hip were obtained from Chinese visible human dataset. The hip model includes acetabular bone, cartilage, labrum, and bone. The cartilage of femoral head was constructed using the AutoCAD and Solidworks software. The hip model was imported into ABAQUS analysis system. The contact surface of the hip joint was meshed. To verify the model, the single leg peak force was loaded, and contact area of the cartilage and labrum of the hip and pressure distribution in these structures were observed. The constructed 3D hip model reflected the real hip anatomy. Further, this model reflected biomechanical behavior similar to previous studies. In conclusion, this 3D finite element hip model avoids the disadvantages of other construction methods, such as imprecision of cartilage construction and the absence of labrum. Further, it provides basic data critical for accurately modeling normal and abnormal loads, and the effects of abnormal loads on the hip.

  4. Danish Hip Arthroscopy Registry (DHAR)

    DEFF Research Database (Denmark)

    Lund, Bent; Mygind-Klavsen, Bjarne; Grønbech Nielsen, Torsten

    2017-01-01

    The Danish Hip Arthroscopy Registry (DHAR) was initiated in January 2012 as a web-based prospective registry. The purpose of this study was to evaluate and report the first registry based outcome data of a national population with radiological and clinical femoroacetabular impingement (FAI......) undergoing hip arthroscopic treatment. Our primary hypothesis was that patients undergoing hip arthroscopy would improve significantly in pain, quality of life and sports related outcome measurements in Patient Related Outcome Measures (PROM). Peri-operative data and Patient Reported Outcome Measures (PROM......-5 D demonstrated improvement after 1 and 2 years from 0.66 pre-op to 0.78 at 2 years. HSAS improved significantly from 2.5 to 3.3. Pain score data demonstrated improvement in NRS-rest 39 to 17 and NRS Walk 49 to 22 at follow-up. We conclude that patients with FAI undergoing hip arthroscopy...

  5. Imaging of the hip

    International Nuclear Information System (INIS)

    Karantanas, A.

    2012-01-01

    Full text: Standard radiographs represent the basic tool of hip joint imaging. For detailed analysis of abnormalities related to bone marrow, articular cartilage, labrum and periarticular soft tissues, MRI has become the method of choice. MR arthrography is superior to standard MRI with regard to depicting the intra-articular abnormalities. CT is supporting plain radiographs for accurate depiction of subtle bone details. Ultrasound is commonly used in postoperative hematoma, bursitis, initial diagnosis of cysts and solid soft tissue tumors as well as for image guided injections and biopsies. Bone scintigraphy is suitable for the mapping of multifocal disease, such as osseous metastatic deposits. PET and PET/CT may be able to differentiate malignant neoplasm and infection from other abnormalities. A common disorder often requested for evaluation, is osteoarthritis. MRI is able to depict early degenerative changes which are occult on plain radiographs. CT- or MR arthrography provide a better evaluation of these changes but should only be performed in cases in which conservative surgery is considered to offer a significant clinical improvement for the patient. These cases include cam type femoroacetabular impingement and traumatic chondrolysis. MRI is an imaging technique that allows direct visualization of the bone marrow. Marrow disorders of the hip may induce a variety of imaging findings and frequently are not detected by conventional radiographic techniques until they have reached an advanced clinical stage. The excellent spatial and contrast resolution provided by MRI facilitates early detection and evaluation of various disorders allowing thus prompt treatment. Imaging findings may alter or guide the correct treatment. In addition, the association of marrow changes and pain such as in osteonecrosis and osteoarthritis is clinically relevant. For imaging the bone marrow, we use a combination of pulse sequences, including T1-w spin echo, PD/T2-w turbo spin echo

  6. Hip morphology predicts posterior hip impingement in a cadaveric model.

    Science.gov (United States)

    Morris, William Z; Fowers, Cody A; Weinberg, Douglas S; Millis, Michael B; Tu, Leigh-Anne; Liu, Raymond W

    2018-05-01

    Posterior hip impingement is a recently-identified cause of hip pain. The purpose of this study is to characterise posterior femoroacetabular and ischiofemoral impingement and identify its predisposing morphologic traits. Two hundred and six cadaveric hips were randomly selected and taken through controlled motion in two pure axes associated with posterior hip impingement: external rotation (through the mechanical axis) and adduction (coronal plane). The range of motion and location of impingement was noted for each specimen. Morphologic traits including femoral/acetabular version, and true neck-shaft angle (TNSA) were also measured. External rotation impingement occurred between the femoral neck and acetabulum in 83.0% of hips, and between the lesser trochanter and ischial tuberosity in 17.0%. Adduction impingement occurred between the lesser trochanter and ischial tuberosity in 78.6% of hips, and between the femoral neck and acetabulum in 21.4%. Multiple regression revealed that increased femoral/acetabular version predicted earlier external rotation and adduction impingement. Unstandardised betas ranging from -0.39 to -0.64 reflect that each degree of increased femoral/acetabular version individually accounts for a loss of external rotation or adduction of approximately half a degree before impingement ( p < 0.001 for each). Increased TNSA was associated with earlier adduction impingement only (unstandardised beta -0.35, p = 0.005). Relative femoral/acetabular anteversion was associated with earlier posterior hip impingement. Coxa valga was associated with earlier adduction impingement, but protective against external rotation impingement. These findings highlight the importance of monitoring correction during femoral/acetabular osteotomies, as overcorrection of retroversion may predispose to earlier posterior impingement.

  7. Has the Reform of the Japanese Healthcare Provision System Improved the Value in Healthcare? A Cost-Consequence Analysis of Organized Care for Hip Fracture Patients.

    Science.gov (United States)

    Fukuda, Haruhisa; Shimizu, Sayuri; Ishizaki, Tatsuro

    2015-01-01

    To assess the value of organized care by comparing the clinical outcomes and healthcare expenditure between the conventional Japanese "integrated care across specialties within one hospital" mode of providing healthcare and the prospective approach of "organized care across separate facilities within a community". Retrospective cohort study. Two groups of hospitals were categorized according to healthcare delivery approach: the first group included 3 hospitals autonomously providing integrated care across specialties, and the second group included 4 acute care hospitals and 7 rehabilitative care hospitals providing organized care across separate facilities. Patients aged 65 years and above who had undergone hip fracture surgery. Regression models adjusting for patient characteristics and clinical variables were used to investigate the impact of organized care on the improvements to the mobility capability of patients before and after hospitalization and the differences in healthcare resource utilization. The sample for analysis included 837 hip fracture surgery cases. The proportion of patients with either unchanged or improved mobility capability was not statistically associated with the healthcare delivery approaches. Total adjusted mean healthcare expenditure for integrated care and organized care were US$28,360 (95% confidence interval: 27,787-28,972) and US$21,951 (21,511-22,420), respectively, indicating an average increase of US$6,409 in organized care. Our cost-consequence analysis underscores the need to further investigate the actual contribution of organized care to the provision of efficient and high-quality healthcare.

  8. Hip Hip Hurrah! Hip size inversely related to heart disease and total mortality

    DEFF Research Database (Denmark)

    Heitmann, B L; Lissner, L

    2011-01-01

    During the past decade a series of published reports have examined the value of studying the relation between hip circumferences and cardiovascular end points. Specifically, in a series of recent studies the independent effects of hip circumference have been studied after adjustment for general o...... for women than men, but is evident in both genders. In this 'viewpoint', we wish to draw attention to the emerging body of evidence and to encourage researchers to continue collecting measures of lower body size in their surveys....... obesity and/or waist circumference. These studies have been remarkable in terms of their consistency, and in the unexpected finding of an adverse effect of small hip size, after statistically correcting for differences in general and abdominal size. The hazard related to a small hip size may be stronger...

  9. Influence of Different Hip Joint Centre Locations on Hip and Knee Joint Kinetics and Kinematics During the Squat

    Directory of Open Access Journals (Sweden)

    Sinclair Jonathan

    2014-12-01

    Full Text Available Identification of the hip joint centre (HJC is important in the biomechanical examination of human movement. However, there is yet to be any published information regarding the influence of different HJC locations on hip and knee joint kinetics during functional tasks. This study aimed to examine the influence of four different HJC techniques on 3- D hip and knee joint kinetics/kinematics during the squat. Hip and knee joint kinetics/kinematics of the squat were obtained from fifteen male participants using an eight camera motion capture system. The 3-D kinetics/kinematics of the squat were quantified using four hip joint centre estimation techniques. Repeated measures ANOVAs were used to compare the discrete parameters as a function of each HJC location. The results show that significant differences in joint angles and moment parameters were evident at both the hip and knee joint in the coronal and transverse planes. These observations indicate that when calculating non-sagittal joint kinetics/kinematics during the squat, researchers should carefully consider their HJC method as it may significantly affect the interpretation of their data.

  10. Combined influence of leisure time physical activity and hip circumference on all-cause mortality

    DEFF Research Database (Denmark)

    Østergaard, Jane Nautrup; Grønbæk, Morten; Ängquist, Lars Henrik

    2013-01-01

    Hip circumference has been shown to be inversely associated with mortality. Muscle atrophy in the gluteofemoral region may be a possible explanation and thus physical activity is likely to play an important role. We aimed to estimate the combined effects of hip circumference and physical activity...... followed to 2009 in the Danish Civil Registration System, with 1.3% loss to follow-up and 2513 deaths. Hazard ratios (HR) were estimated for combinations of physical activity and hip circumference. Hip circumference was inversely associated with mortality irrespective of being physically active or not....... However, being physically active seemed to counterbalance some of the adverse health effects of a small hip circumference; when comparing inactive to active, the excess mortality at the 25(th) percentile of hip circumference is 40% in men (HR= 1.40, 95% CI: 1.14-1.72) and 33% in women (HR= 1.33, CI: 1...

  11. Osteochondritis Dissecans of the Hip

    International Nuclear Information System (INIS)

    Linden, B.; Jonsson, K.; Redlund-Johnell, I.

    2003-01-01

    Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended

  12. Osteochondritis Dissecans of the Hip

    Energy Technology Data Exchange (ETDEWEB)

    Linden, B. [Hoeglands Hospital, Eksjoe (Sweden). Dept. of Orthopedic Surgery; Jonsson, K. [Univ. Hospital, Lund (Sweden). Center for Medical Imaging and Physiology; Redlund-Johnell, I. [Univ. Hospital, Malmoe (Sweden). Dept. of Diagnostic Radiology

    2003-03-01

    Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended.

  13. Cardiac transplant due to metal toxicity associated with hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Sheldon Moniz, MBBS (UWA

    2017-09-01

    Full Text Available Concerns regarding metal-on-metal (MoM bearing couples in total hip arthroplasty are well documented in the literature with cobalt (Co and chromium (Cr toxicity causing a range of both local and systemic adverse reactions. We describe the case of a patient undergoing cardiac transplantation as a direct result of Co and Cr toxicity following a MoM hip replacement. Poor implant positioning led to catastrophic wear generating abundant wear particles leading to Co and Cr toxicity, metallosis, bony destruction, elevated metal ion levels, and adverse biological responses. Systemic symptoms continued for 3 years following cardiac transplantation with resolution only after revision hip arthroplasty. There was no realization in the initial cardiac assessment and subsequent transplant workup that the hip replacement was the likely cause of the cardiac failure, and the hip replacement was not recognized as the cause until years after the heart transplant. This case highlights the need for clinicians to be aware of systemic MoM complications as well as the importance of positioning when using these prostheses.

  14. Sports Activity Following Cementless Metaphyseal Hip Joint Arthroplasty

    Directory of Open Access Journals (Sweden)

    Czech Szymon

    2017-12-01

    Full Text Available An adequate level of physical activity has a substantial effect on both mental and physical human health. Physical activity is largely dependent on the function of the musculoskeletal and articular system. One of the most frequent diseases of this system is degenerative joint disease. Due to the changing and more demanding lifestyles and patients’ willingness to be involved in sports activity, the expectations of hip joint arthroplasty are becoming increasingly high. Alleviating pain ceases to be the only reason for which patients choose surgical interventions, while the expectations often include involvement in various sports. Only few studies contain recommendations concerning the frequency, type and intensity of sports activity which are acceptable after hip joint arthroplasty. The aim of the study was to evaluate function and physical activity of people following cementless short-stem hip joint arthroplasty in the observation of at least five years. The study group comprised 106 patients who underwent total hip arthroplasty due to degenerative joint diseases, chosen according to inclusion criteria. Patients underwent routine physical examinations following the Harris Hip Score protocol, responded to the UCLA scale and questionnaires concerning pre-surgical and current physical activity. Our results demonstrated that hip joint arthroplasty in people suffering from degenerative joint diseases has a beneficial effect on their level of functioning and physical activity. Although physical activity and the level of functioning obviously reduced as a person aged, the level of physical activity continued to be very high in both groups, with function of the hip joint evaluated as very good.

  15. Emerging topics on the hip: Ligamentum teres and hip microinstability

    International Nuclear Information System (INIS)

    Cerezal, Luis; Arnaiz, Javier; Canga, Ana; Piedra, Tatiana; Altónaga, José R.; Munafo, Ricardo; Pérez-Carro, Luis

    2012-01-01

    Microinstability and ligament teres lesions are emergent topics on the hip pathology. These entities are an increasingly recognized cause of persistent hip pain and should be considered in the differential diagnosis of the patient with hip pain. Conventional (non-arthrographic) CT and MR have a very limited role in the evaluation of these entities. CTa and MRa have emerged as the modalities of choice for pre-operative imaging of ligamentum teres injuries and microinstability. To date, pre-operative imaging detection of these pathologies is not widespread but with appropriate imaging and a high index of suspicion, preoperative detection should improve. This article discusses current concepts regarding anatomy, biomechanics, clinical findings, diagnosis and treatment of ligament teres lesions and microinstability.

  16. Brief concept of hip preservation

    Directory of Open Access Journals (Sweden)

    Sanjeev S. Madan

    2017-12-01

    Full Text Available Restoration of the anatomy of the hip joint and biomechanics across it, carry the immense importance to prevent future osteoarthritis of the joint. The aim of this review is to provide the brief concept of the methods to preserve the hip, especially in young adults. Attempts to preserve the hips start with the intense preoperative planning of the corrective procedure. Different parameters regarding the femur and acetabulum in all 3 dimensions need to be assessed. Especially, measurement of the anteversion of the femur and acetabulum is a significant step to avoid osteoarthritis. In addition, the suprapelvic and infrapelvic (spine and lower limb lengths alignment needs to be considered in the planning. Correction of the femoral side of the hip needs the understanding of the blood supply of the proximal femur which carries the risk of avascular necrosis more so with intracapsular osteotomies. Acetabular reorientation, to re-distribute the forces over the weight bearing part, can be carried out with re-directional osteotomy such as periacetabular osteotomy. It needs the understanding of the acetabular anatomy and the force distribution in it. To conclude, correction of both femoral and acetabular side parameters need to be considered in decision making depending on the alterations due to various etiologies causing the hip disorders.

  17. Traumatic hip dislocations in children

    International Nuclear Information System (INIS)

    Minhas, M.S.

    2010-01-01

    Objectives: To evaluate clinical features, treatment and relationship to the time period between dislocation, reduction and early complications of traumatic dislocation of hip in children. Methods: Case series conducted at Jinnah Post Graduate Medical Centre Karachi from July 2005 to August 2009. Children with traumatic hip dislocation up to fifteen years of age who presented in last four years were included in this study. Their clinical information, etiology, associated injuries, duration, method of reduction and early complications are evaluated through emergency room proforma and indoor record. Follow up of patient was updated in outpatient department. Results: We had eight patients, six boys and two girls. Youngest 2.4 years and eldest was 12 years with mean age of 6.2 +- 3.8 years. All presented with posterior hip dislocation. Etiology was road traffic accident in two and history of fall in remaining six patients. Average duration of time between dislocation and reduction was 19 hours range 3-72 hours. Dislocated hips were reduced under General Anaesthesia in two patients and under sedation analgesia in six patients. No complications were noted in eight cases with mean 18.75 +- 13.23 months follows up. Conclusion: Traumatic hip dislocation in children is not rare. Slight trauma causes dislocation in younger age and immediate closed reduction and Immobilization reduces complications. (author

  18. Hip joint torques during the golf swing of young and senior healthy males.

    Science.gov (United States)

    Foxworth, Judy L; Millar, Audrey L; Long, Benjamin L; Way, Michael; Vellucci, Matthew W; Vogler, Joshua D

    2013-09-01

    Descriptive, laboratory study. To compare the 3-D hip torques during a golf swing between young and senior healthy male amateur golfers. The secondary purpose was to compare the 3-D hip joint torques between the trail leg and lead leg. The generation of hip torques from the hip musculature is an important aspect of the golf swing. Golf is a very popular activity, and estimates of hip torques during the golf swing have not been reported. Twenty healthy male golfers were divided into a young group (mean ± SD age, 25.1 ± 3.1 years) and a senior group (age, 56.9 ± 4.7 years). All subjects completed 10 golf swings using their personal driver. A motion capture system and force plates were used to obtain kinematic and kinetic data. Inverse dynamic analyses were used to calculate 3-D hip joint torques of the trail and lead limbs. Two-way analyses of covariance (group by leg), with club-head velocity as a covariate, were used to compare peak hip torques between groups and limbs. Trail-limb hip external rotator torque was significantly greater in the younger group compared to the senior group, and greater in the trail leg versus the lead leg. When adjusting for club-head velocity, young and senior healthy male amateur golfers generated comparable hip torques during a golf swing, with the exception of the trail-limb hip external rotator torque. The largest hip torque found was the trail-limb hip extensor torque.

  19. Fascia iliaca compartment blockade for acute pain control in hip fracture patients

    DEFF Research Database (Denmark)

    Foss, Nicolai B; Kristensen, Billy B; Bundgaard, Morten

    2007-01-01

    Hip fracture patients are in severe pain upon arrival at the emergency department. Pain treatment is traditionally based on systemic opioids. No study has examined the effect of fascia iliaca compartment blockade (FICB) in acute hip fracture pain management within a double-blind, randomized setup....

  20. Cementless Hydroxyapatite Coated Hip Prostheses

    Science.gov (United States)

    Herrera, Antonio; Mateo, Jesús; Gil-Albarova, Jorge; Lobo-Escolar, Antonio; Ibarz, Elena; Gabarre, Sergio; Más, Yolanda

    2015-01-01

    More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality. PMID:25802848

  1. Developmental hip dysplasia in adolescence

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2009-01-01

    Full Text Available The authors define adolescence and developmental dysplasia of the hip (DDH. Special attention is paid to pathological findings characteristic of DDH in adolescence (unrecognized and untreated DDH; treated DDH, but non-terminated treatment; DDH diagnosed with delay, inadequately treated, with complications. The authors emphasise that DDH treatment has to be successfully terminated well before the adolescence; possibilities are explained on management modes at the time of adolescence, and possible persons guilty for the persistence of later hip problems are indicated. Based on the authors' experience and having in mind all surgical possibilities for the treatment (pelvic osteotomies, femoral osteotomies, trochanteroplasties, leg length equalization procedures the authors propose treatment protocols. The intention is to provide better treatment results and to prevent secondary hip arthrosis. Furthermore, how to improve the struggle against DDH is suggested.

  2. MRI of the hip joint

    International Nuclear Information System (INIS)

    Czerny, C.; Noebauer-Huhmann, I.M.; Imhof, H.

    2005-01-01

    Magnetic resonance imaging (MRI) is performed to diagnose many pathologic conditions affecting the hip joint. Either conventional MRI (without contrast enhancement of the joint cavity) or MR arthrography is used to detect and most accurately differentiate hip joint pathologies. Conventional MRI is performed in cases of bone marrow edema, necrosis, arthrosis and especially the so-called ''activated arthrosis'', as well as in inflammatory and tumorous entities. MR arthography, which has only recently become available for use, is excellently suited for diagnosing lesions of the acetabular labrum, cartilage lesions, and free articular bodies. This article provides an overview about MRI characteristics and their accuracy of hip joint diseases and the impact on the therapeutic procedure. (orig.)

  3. Cementless Hydroxyapatite Coated Hip Prostheses

    Directory of Open Access Journals (Sweden)

    Antonio Herrera

    2015-01-01

    Full Text Available More than twenty years ago, hydroxyapatite (HA, calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality.

  4. Risks of hip and knee replacement

    Science.gov (United States)

    ... is normal to lose blood during and after hip or knee replacement surgery. Some people need a ... clot form are higher during and soon after hip or knee replacement surgery. Sitting or lying down ...

  5. Exercise therapy may postpone total hip replacement surgery in patients with hip osteoarthritis

    DEFF Research Database (Denmark)

    Svege, Ida; Nordsletten, Lars; Fernandes, Linda

    2015-01-01

    Exercise treatment is recommended for all patients with hip osteoarthritis (OA), but its effect on the long-term need for total hip replacement (THR) is unknown.......Exercise treatment is recommended for all patients with hip osteoarthritis (OA), but its effect on the long-term need for total hip replacement (THR) is unknown....

  6. Reverse hybrid total hip arthroplasty

    DEFF Research Database (Denmark)

    Wangen, Helge; Havelin, Leif I.; Fenstad, Anne M

    2017-01-01

    Background and purpose - The use of a cemented cup together with an uncemented stem in total hip arthroplasty (THA) has become popular in Norway and Sweden during the last decade. The results of this prosthetic concept, reverse hybrid THA, have been sparsely described. The Nordic Arthroplasty....... Patients and methods - From the NARA, we extracted data on reverse hybrid THAs from January 1, 2000 until December 31, 2013. 38,415 such hips were studied and compared with cemented THAs. The Kaplan-Meier method and Cox regression analyses were used to estimate the prosthesis survival and the relative risk...

  7. Computed tomography in abnormalities of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Visser, J.D.; Jonkers, A.; Klasen, H.J. (Rijksuniversiteit Groningen (Netherlands). Academisch Ziekenhuis); Hillen, B. (Rijksuniversiteit Groningen (Netherlands). Lab. voor Anatomie en Embryologie)

    1982-06-26

    The value of computed tomography in the assessment of abnormalities of the hip is demonstrated with the aid of an anatomical preparation and in patients with, respectively, congenital dislocation of a hip, dislocation of the hip in spina bifida, an acetabular fracture and a Ewing tumour. The anteversion of the acetabulum and femur and the instability index of the hip joint can be measured by means of computed tomography.

  8. Adventure sports and sexual freedom hip replacement: the tripolar hip.

    Science.gov (United States)

    Pritchett, James W

    2018-01-01

    Certain athletic activities and lifestyles require a completely stable and very mobile hip. Total hip replacement with a natural femoral head size and two mobile-bearing surfaces (i.e., a "tripolar" prosthesis) is the most stable prosthesis. Elegant design and wear-resistant bearing surfaces are the keys to long-term implant survivorship. The hypothesis is that a ceramic-coated tripolar prosthesis using highly cross-linked polyethylene can provide full function and complete stability with low wear. This study sought to determine: (1) patient-reported outcomes, (2) functional outcomes, (3) implant survivorship and complications, and (4) postoperative sexual limitations. Between 1998 and 2011, the author performed 160 primary total hip replacements using tripolar prostheses in patients participating in adventure sports and other physically demanding activities. The institutional review board approved this study. The inclusion criteria were patients who needed unrestricted activity and who were not candidates for or did not choose hip resurfacing. Patients were followed every second year and assessed with radiographs, Harris Hip Score, WOMAC, SF-12, and UCLA functional outcome scores. Patients were asked about symptoms of instability and satisfaction with their hip replacement. Patients were asked both preoperatively and 2 years postoperatively four questions about their sexual activity. Mean follow-up was 11 years. At 2 years' postoperatively, 98% of patients reported their satisfaction as excellent or good and 99% were not limited for sexual activity following surgery. Seventy-four percent of patients reported they were recovered within 6 weeks of surgery. There were no dislocations. There were three revision procedures for implant loosening, infection, and periprosthetic fracture, but there were no failures of the tripolar articulation. The mean postoperative UCLA score was the highly athletic score of 8. There were no signs of osteolysis, wear, or metal

  9. Treatment of tuberculosis of the hip.

    African Journals Online (AJOL)

    The common presentation was a swollen hip, a limp, decreased range of hip movements, fixed flexion deformity and pain. Three patients had protrusio acetabuli and three had subluxed or dislocated hips. Twenty-three patients were anaemic and the erythrocyte sedimentation rate (ESR) was raised in all (mean. 6 5 d h r ...

  10. Hip-Hop and the Academic Canon

    Science.gov (United States)

    Abe, Daudi

    2009-01-01

    Over the last 30 years, the hip-hop movement has risen from the margins to become the preeminent force in US popular culture. In more recent times academics have begun to harness the power of hip-hop culture and use it as a means of infusing transformative knowledge into the mainstream academic discourse. On many college campuses, hip-hop's…

  11. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  12. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) trunnion-bearing... Devices § 888.3380 Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis is a two...

  13. Net-Shape HIP Powder Metallurgy Components for Rocket Engines

    Science.gov (United States)

    Bampton, Cliff; Goodin, Wes; VanDaam, Tom; Creeger, Gordon; James, Steve

    2005-01-01

    True net shape consolidation of powder metal (PM) by hot isostatic pressing (HIP) provides opportunities for many cost, performance and life benefits over conventional fabrication processes for large rocket engine structures. Various forms of selectively net-shape PM have been around for thirty years or so. However, it is only recently that major applications have been pursued for rocket engine hardware fabricated in the United States. The method employs sacrificial metallic tooling (HIP capsule and shaped inserts), which is removed from the part after HIP consolidation of the powder, by selective acid dissolution. Full exploitation of net-shape PM requires innovative approaches in both component design and materials and processing details. The benefits include: uniform and homogeneous microstructure with no porosity, irrespective of component shape and size; elimination of welds and the associated quality and life limitations; removal of traditional producibility constraints on design freedom, such as forgeability and machinability, and scale-up to very large, monolithic parts, limited only by the size of existing HIP furnaces. Net-shape PM HIP also enables fabrication of complex configurations providing additional, unique functionalities. The progress made in these areas will be described. Then critical aspects of the technology that still require significant further development and maturation will be discussed from the perspective of an engine systems builder and end-user of the technology.

  14. [Multidisciplinary approach of hip fractures based on Hungarian data].

    Science.gov (United States)

    Juhász, Krisztina; Turchányi, Béla; Mintál, Tibor; Somogyi, Péter

    2016-09-01

    Hip fractures are described by increased mortality, loss of quality of life, functional decline and burden of diseases. They show a growing number worldwide. The aim of the present study is to summarise the existing data on the incidence, mortality, complications and rehabilitation of hip fractures, which relevance is reported only by few studies. To reduce mortality and complications of hip fractures the authors emphasize the importance of primary treatment within 12 hours, appropriate selection of surgical methods corresponding to the fracture type after the assessment of femoral head viability, vitamin D supplementation, same conditions for primary treatment during everyday of the week, and an adequate acute treatment and rehabilitation for patient's general health status. In the future integrated processing of multidisciplinary results of hip fractures based on Hungarian data can support the development of efficient treatment and prevention strategies, which can be advantageous for the patient, families, health care system, and the society, too, by the reduction of costly complications of hip fracture healing and mortality. Orv. Hetil., 2016, 157(37), 1469-1475.

  15. Dose reduction of radiographs of the pediatric pelvis for diagnosing hip dysplasia using a digital flat-panel detector system; Dosisreduktion bei Roentgenaufnahmen des kindlichen Beckenskelettes zur Diagnostik der Hueftgelenksdysplasie unter Verwendung eines digitalen Flachdetektorsystems

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, K.; Ahlers, K.; Kloska, S.; Vieth, V.; Meier, N.; Heindel, W. [Inst. fuer Klinische Radiologie, Westfaelische Wilhelms-Univ. Muenster (Germany); Sandmann, C.; Gosheger, G. [Orthopaedische Klinik, Westfaelische Wilhelms-Univ. Muenster (Germany)

    2003-01-01

    Purpose: To evaluate a possible dose reduction in pediatric pelvic radiographs in congenital hip dysplasia using a digital flat-panel system instead of a phosphor-storage system. Materials and Methods: During a six-month period, all pediatric patients referred for pelvic radiography for the evaluation of congenital hip dysplasia were randomely assigned to be examined by either a phosphor-storage system or a digital flat-panel system, whereby the latter system was operated with half the radiation dose. Thirty pairs of radiographs were assessed for the visibility of 16 anatomic details and for 5 orthopedic-radiographic measurements (5-point scale with 1 = excellent; three independent observers). The projection indices of Ball and Kommenda and of Toennis and Brunken were calculated for all radiographs. The Student's t-test was used to compare the flat-panel and the phosphor-storage radiographs for observers' assessments, patients' age and projection indices. Results: In a total of 7560 observations, the scores for the visibility of anatomic details and orthopedic-radiographic measurements were respectively 2.72 and 2.64 for the flat-panel system and 2.93 and 2.79 for the phosphor-storage system. No significant differences were found between both systems (p > 0.05) and between patient age and projection indices (p > 0.05). Conclusion: Pediatric pelvic radiographs can be obtained with a digital flat-panel system using half the radiation dose instead of a phosphor-storage system without sacrificing relevant information in the diagnosis of congenital hip dysplasia. (orig.) [German] Zielsetzung: Evaluation einer moeglichen Dosisreduktion bei kindlichen Beckenroentgenaufnahmen zur Diagnostik der Hueftgelenksdysplasie mit einem digitalen Flachdetektorsystem im Vergleich zu einem digitalen Speicherfoliensystem. Material und Methoden: Prospektiv wurden alle ueber einen Zeitraum von 6 Monaten zur Roentgenaufnahme des Beckenskelettes im Rahmen der Diagnostik der

  16. Hip-Hop Pop Art

    Science.gov (United States)

    Talley, Clarence, Sr.

    2011-01-01

    Art has a way of helping students better understand and appreciate the world around them, particularly the things that are most important to them. Hip hop is one of those generational genres that capture the attention of young students like few other things do. Drawing on this genre to get students to create art is an excellent way to demonstrate…

  17. Improving hip surgery patients’ outcomes:

    DEFF Research Database (Denmark)

    Bagger, Bettan; Poulsen, Dorthe Varning; Taylor Kelly, Hélène

    This presentation focuses upon the improvement of hip surgery patients’ outcomes with respect to health promotion and rehabilitation. The overall aims of the EU financed orthopedic nursing project will be introduced. Speakers highlight the project’s contribution to: -the development of nurse...

  18. Imaging of hip joint arthroplasty

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Fruehwald-Pallamar, J.; Czerny, C.

    2009-01-01

    The hip joint is the largest joint in the human body and consequently, its evaluation by diagnostic imaging is highly important. This includes imaging of hip joint arthroplasty, which is used to avoid joint immobility following a wide spectrum of diseases, such as end-stage degenerative disease, avascular necrosis of the femoral head or post-traumatic fractures. Conventional radiography is still the standard imaging modality for the evaluation of hip arthroplasty both directly following surgery and for periodical follow-up. In the majority of cases conventional radiography enables adequate assessment of early and late complications that can arise following hip arthroplasty, such as loosening, prosthetic or periprosthetic fracture, luxation, infection and soft tissue calcification. If the diagnosis cannot be established by means of radiography, advanced imaging methods such as computed tomography (CT) and magnetic resonance imaging (MRI), with or without injection of contrast media, may provide additional information. This is particularly true for the depiction of inflammatory processes. Regardless of the imaging modality used patients' clinical symptoms must also be taken into account in order to establish the correct diagnosis. (orig.) [de

  19. The tribology of metal-on-metal total hip replacements.

    Science.gov (United States)

    Scholes, S C; Unsworth, A

    2006-02-01

    Total hip surgery is an effective way of alleviating the pain and discomfort caused by diseased or damaged joints. However, in the majority of cases, these joints have a finite life. The main reason for failure is osteolysis (bone resorption). It is well documented that an important cause of osteolysis, and therefore the subsequent loosening and failure of conventional metal- or ceramic-on-ultra-high molecular weight polyethylene joints, is the body's immunological response to the polyethylene wear particles. To avoid this, interest has been renewed in metal-on-metal joints. The intention of this paper is to review the studies that have taken place within different laboratories to determine the tribological performance of new-generation metal-on-metal total hip replacements. These types of joint offer a potential solution to enhance the longevity of prosthetic hip systems; however, problems may arise owing to the effects of metal ion release, which are, as yet, not fully understood.

  20. Periprosthetic fungal infection of a hip caused by Trichosporon inkin

    Directory of Open Access Journals (Sweden)

    Federico José Burgo, MD

    2018-03-01

    Full Text Available An immunocompromised patient with a history of multiple hip implant revisions extended courses of empiric antibiotic treatment, and a retained metallic rod in the femoral medullary canal was transferred for diagnostic studies and treatment. A high suspicion of fungal infection and utilization of extended and specific fungal cultures were the diagnostic keys for infection with Trichosporon inkin. The treatment consisted in a debridement surgery with the use of a functional spacer with cement supplemented with voriconazole and vancomycin plus a 6-month systemic treatment with voriconazole. After 2 years of follow-up, the patient is free of symptoms. Keywords: Hip arthroplasty, Periprosthetic fungal infection, Trichosporon inkin

  1. HiPS - Hierarchical Progressive Survey Version 1.0

    Science.gov (United States)

    Fernique, Pierre; Allen, Mark; Boch, Thomas; Donaldson, Tom; Durand, Daniel; Ebisawa, Ken; Michel, Laurent; Salgado, Jesus; Stoehr, Felix; Fernique, Pierre

    2017-05-01

    This document presents HiPS, a hierarchical scheme for the description, storage and access of sky survey data. The system is based on hierarchical tiling of sky regions at finer and finer spatial resolution which facilitates a progressive view of a survey, and supports multi-resolution zooming and panning. HiPS uses the HEALPix tessellation of the sky as the basis for the scheme and is implemented as a simple file structure with a direct indexing scheme that leads to practical implementations.

  2. Recurrent Hip Fracture Prevention With Osteoporosis Management

    Directory of Open Access Journals (Sweden)

    A. Shahla

    2007-02-01

    Full Text Available Background:Osteoporosis is a major public health threat,and hip fracture is a serious consequence of osteoporosis.Apatient with an osteoporosis-related hip fracture has an increased risk for a second hip fracture.The effect of osteoporosis management on the risk of recurrent hip fracture was evaluated in this study.Methods:58 hip fracture patients older than 50yr and BMD < 2.5 were discharged from hospital with Ca-Vitamin D- Alendronate prescriptions, and followed up for 4 years to determine the rate of recurrent hip fractures. Rate of second hip fractures was compared with 58 hip fractures in the control group (without osteoporosis treatment which were also followed for 4 years. Results:72% of patients continued treatment for 2 years. There were no second hip fractures in the critical first 12 months in the treated group.Overall second hip fractures in osteoporosis treated and control groups were 3.4% and 8.6%(p<0.03, respectively.Conclusion:Management of hip fractures in the elderly should include bone mineral density determination and osteoporosis treatment to prevent further fractures.

  3. Hip Imaging in Athletes: Sports Imaging Series.

    Science.gov (United States)

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.

  4. Evolution of the hip and pelvis.

    Science.gov (United States)

    Hogervorst, Tom; Bouma, Heinse W; de Vos, John

    2009-08-01

    Man's evolution features two unique developments: growing a huge brain and upright gait. Their combination makes the pelvis the most defining skeletal element to read human evolution. Recent revival in joint preserving hip surgery have brought to attention morphological variations of the human hip that appear similar to hips of extant mammals. In man, such variations can produce hip osteoarthrosis through motion. We reviewed the evolution of the hip and pelvis with special interest in morphology that can lead to motion induced osteoarthrosis in man. The combination of giving birth to big brained babies and walking upright has produced marked differences between the sexes in pelvis and hip morphology, each having their characteristic mode of hip impingement and osteoarthrosis.

  5. Hip fractures. Epidemiology, risk factors, falls, energy absorption, hip protectors, and prevention

    DEFF Research Database (Denmark)

    Lauritzen, J B

    1997-01-01

    have a high risk of hip fracture (annual rate of 5-6%), and the incidence of falls is about 1,500 falls/1,000 persons/year. Most hip fractures are a result of a direct trauma against the hip. The incidence of falls on the hip among nursing home residents is about 290 falls/1,000 persons/year and about......%, corresponding to 9 out of 247 residents saved from sustaining a hip fracture. The review points to the essentials of the development of hip fracture, which constitutes; risk of fall, type of fall, type of impact, energy absorption, and lastly bone strength, which is the ultimate and last permissive factor......The present review summarizes the pathogenic mechanisms leading to hip fracture based on epidemiological, experimental, and controlled studies. The estimated lifetime risk of hip fracture is about 14% in postmenopausal women and 6% in men. The incidence of hip fractures increases exponentially...

  6. Implementation of a Total Hip Arthroplasty Care Pathway at a High-Volume Health System: Effect on Length of Stay, Discharge Disposition, and 90-Day Complications.

    Science.gov (United States)

    Featherall, Joseph; Brigati, David P; Faour, Mhamad; Messner, William; Higuera, Carlos A

    2018-06-01

    Standardized care pathways are evidence-based algorithms for optimizing an episode of care. Despite the theoretical promise of care pathways, there is an inconsistent literature demonstrating improvements in patient care. The authors hypothesized that implementing a care pathway, across 11 hospitals, would decrease hospital length of stay (LOS), decrease postoperative complications at 90 days, and increase discharges to home. A multidisciplinary team developed an evidence-based care pathway for total hip arthroplasty (THA) perioperative care. All patients receiving THA in 2013 (pre-protocol, historical control), 2014 (transition), and 2015 (full protocol implementation) were included in the analysis. Multivariable regression assessed the relationship of the care pathway to 90-day postoperative complications, LOS, and discharge disposition. Cost savings were estimated using previously published postarthroplasty episode and per diem hospital costs. A total of 6090 primary THAs were conducted during the study period. After adjusting for the covariates, the full protocol implementation was associated with a decrease in LOS (mean ratio, 0.747; 95% confidence interval [CI; 0.727, 0.767]) and an increase in discharges to home (odds ratio, 2.079; 95% CI [1.762, 2.456]). The full protocol implementation was not associated with a change in 90-day complications (odds ratio, 1.023; 95% CI [0.841, 1.245]). Payer-perspective-calculated theoretical cost savings, including both index admission and postdischarge costs, were $2533 per patient. The THA care pathway implementation was successful in reducing LOS and increasing discharges to home. The care pathway was not associated with a change in 90-day complications; further targeted interventions in this area are needed. Despite care standardization efforts, high-volume hospitals and surgeons had higher performance. Extrapolation of theoretical cost savings indicates that widespread THA care pathway adoption could lead to national

  7. Hip dysplasia: a significant risk factor for the development of hip osteoarthritis. A cross-sectional survey

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Sonne-Holm, Stig

    2005-01-01

    joint space width (JSW) /=60 yr of age. Of factors entered into logistic regression analyses, only age (P LT 0.001 for right hips and P LT 0.001 for left hips) and hip dysplasia (P LT 0.001 for right hips and P = 0.004 for left hips) were significantly associated with hip OA prevalence in women. In men......, only hip dysplasia was associated with hip OA prevalence, P LT 0.001 in right hips and P = 0.001 in left hips. CONCLUSIONS: Of the individual risk factors investigated in this study, only age and hip dysplasia were associated with the development of hip osteoarthritis.......OBJECTIVES: The aim of this cross-sectional survey of 2232 women and 1336 men (age range 20-91 yr) was to investigate individual risk factors for hip joint osteoarthritis (OA). METHODS: Standardized, weight-bearing pelvic radiographs were evaluated. Radiological hip joint OA was defined as minimum...

  8. [Range of Hip Joint Motion and Weight of Lower Limb Function under 3D Dynamic Marker].

    Science.gov (United States)

    Xia, Q; Zhang, M; Gao, D; Xia, W T

    2017-12-01

    To explore the range of reasonable weight coefficient of hip joint in lower limb function. When the hip joints of healthy volunteers under normal conditions or fixed at three different positions including functional, flexed and extension positions, the movements of lower limbs were recorded by LUKOtronic motion capture and analysis system. The degree of lower limb function loss was calculated using Fugl-Meyer lower limb function assessment form when the hip joints were fixed at the aforementioned positions. One-way analysis of variance and Tamhane's T2 method were used to proceed statistics analysis and calculate the range of reasonable weight coefficient of hip joint. There were significant differences between the degree of lower limb function loss when the hip joints fixed at flexed and extension positions and at functional position. While the differences between the degree of lower limb function loss when the hip joints fixed at flexed position and extension position had no statistical significance. In 95% confidence interval, the reasonable weight coefficient of hip joint in lower limb function was between 61.05% and 73.34%. Expect confirming the reasonable weight coefficient, the effects of functional and non-functional positions on the degree of lower limb function loss should also be considered for the assessment of hip joint function loss. Copyright© by the Editorial Department of Journal of Forensic Medicine

  9. Unconstrained tripolar hip implants: effect on hip stability.

    Science.gov (United States)

    Guyen, Olivier; Chen, Qing Shan; Bejui-Hugues, Jacques; Berry, Daniel J; An, Kai-Nan

    2007-02-01

    Tripolar implants were developed to treat unstable total hip arthroplasties. However, there is limited confirmation that they achieve this purpose despite their increasing use. Because they have a larger effective head size, these implants are expected to increase range of motion to impingement and improve stability in situations at risk for impingement compared with conventional implants. We assessed the range of motion to impingement using a tripolar implant mounted to an automated hip simulator using 22.2-mm and 28-mm femoral head sizes. The 22 and 28-mm tripolar implants provided increases of 30.5 degrees in flexion, 15.4 degrees in adduction, and 22.4 degrees in external rotation compared with the conventional 22.2-mm femoral head diameter implant. At the critical position of 90 degrees hip flexion, there was an increase of 45.2 degrees in internal rotation. At 0 degrees and 30 degrees external rotation, extension increases were 18.8 degrees and 7.8 degrees, respectively. Bony impingement was the limiting factor. Tripolar implants increased the arc of motion before impingement in positions at risk for dislocation and are expected to provide greater stability.

  10. SU-E-J-230: Effect of Metal Hip Prosthesis On the Accuracy of Electromagnetic Localization and Tracking

    International Nuclear Information System (INIS)

    Butler, W; Merrick, G; Kurko, B; Bittner, N

    2014-01-01

    Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from the phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible

  11. BILATERAL PATHOLOGICAL HIP DISLOCATION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Yuriy E. Garkavenko

    2017-03-01

    Full Text Available Introduction. Pathological dislocation of the hip is one of the most severe complications of acute hematogenous osteomyelitis. The program of treatment for children with pathological hip dislocation is complex, but it has been sufficiently developed and implemented very successfully. At the same time, the available literature provides no cases of treating children with bilateral pathological hip dislocations after hematogenous osteomyelitis. There is no information on the incidence of such cases or in regards to remote functional results. Materials and methods. The results of the treatment of 18 children with bilateral pathological dislocation of the hip after hematogenous osteomyelitis are presented, which constituted 23.1% of the total number of patients (78 who underwent surgery in 2000–2016 for the diagnosis of pathological hip dislocation. Both hip joints were surgically operated on in 12 patients, while one hip joint was operated on in 6 patients. To assess the anatomical and functional state of hip joints, the clinical and roentgenological diagnostic techniques were used. Results and discussion. To stabilize and restore the function of the hip joints, 18 children underwent 30 surgical interventions: simple open hip reduction (19 and open hip reduction with hip arthroplasty with one (6 or two (5 demineralized osteochondral allogeneic grafts. The decision regarding the possibility of performing surgical intervention on the second hip joint was made only after a child's check-up examination was complete and after positive information about the anatomical and functional state of the operated hip joint was obtained. According to these criteria, 14 (77.8% children underwent surgical treatment of the second hip joint 1–1.5 years after the course of conservative measures to restore the range of motion in the previously operated hip joint. Over a period of 1–12 years, 17 patients were examined, 10 of which underwent an operation on both

  12. Anchorage strategies in geriatric hip fracture management

    Directory of Open Access Journals (Sweden)

    Knobe Matthias

    2016-12-01

    Full Text Available There is an enormous humanitarian and socioeconomic need to improve the quality and effectiveness of care for patients with hip fracture. To reduce mechanical complications in the osteosynthesis of proximal femoral fractures, improved fixation techniques have been developed including blade or screw-anchor devices, locked minimally invasive or cement augmentation strategies. However, despite numerous innovations and advances regarding implant design and surgical techniques, systemic and mechanical complication rates remain high. Treatment success depends on secure implant fixation in often-osteoporotic bone as well as on patient-specific factors (fracture stability, bone quality, comorbidity, and gender and surgeon-related factors (experience, correct reduction, and optimal screw placement in the head/neck fragment. For fracture fixation, the anchorage of the lag screw within the femoral head plays a crucial role depending on the implant’s design. Meta-analyses and randomized controlled studies demonstrate that there is a strong trend towards arthroplasty treating geriatric femoral neck fractures. However, for young adults as well as older patients with less compromised bone quality, or in undisplaced fractures, head-preserving therapy is preferred as it is less invasive and associated with good functional results. This review summarizes the evidence for the internal fixation of femoral neck fractures and trochanteric femoral fractures in elderly patients. In addition, biomechanical considerations regarding implant anchorage in the femoral head including rotation, migration, and femoral neck shortening are made. Finally, cement augmentation strategies for hip fracture implants are evaluated critically.

  13. Economic viability of geriatric hip fracture centers.

    Science.gov (United States)

    Clement, R Carter; Ahn, Jaimo; Mehta, Samir; Bernstein, Joseph

    2013-12-01

    Management of geriatric hip fractures in a protocol-driven center can improve outcomes and reduce costs. Nonetheless, this approach has not spread as broadly as the effectiveness data would imply. One possible explanation is that operating such a center is not perceived as financially worthwhile. To assess the economic viability of dedicated hip fracture centers, the authors built a financial model to estimate profit as a function of costs, reimbursement, and patient volume in 3 settings: an average US hip fracture program, a highly efficient center, and an academic hospital without a specific hip fracture program. Results were tested with sensitivity analysis. A local market analysis was conducted to assess the feasibility of supporting profitable hip fracture centers. The results demonstrate that hip fracture treatment only becomes profitable when the annual caseload exceeds approximately 72, assuming costs characteristic of a typical US hip fracture program. The threshold of profitability is 49 cases per year for high-efficiency hip fracture centers and 151 for the urban academic hospital under review. The largest determinant of profit is reimbursement, followed by costs and volume. In the authors’ home market, 168 hospitals offer hip fracture care, yet 85% fall below the 72-case threshold. Hip fracture centers can be highly profitable through low costs and, especially, high revenues. However, most hospitals likely lose money by offering hip fracture care due to inadequate volume. Thus, both large and small facilities would benefit financially from the consolidation of hip fracture care at dedicated hip fracture centers. Typical US cities have adequate volume to support several such centers.

  14. Hip fractures in old men

    International Nuclear Information System (INIS)

    Martinez Rondanelli, Alfredo

    2005-01-01

    Describe 289 hip fractures that were admitted at Hospital Universitario del Valle between November 1, 2003 and June 30, 2004. The patients had the first appointment at 2.7 days after the fallen, 60% the patients were women, at he age average were 75 years. In the hospital 228 patients were operated (79%). The surgery was realized in average at the twelve days after than they were admitted at the hospital. The days in the hospital were in average 17.5 days. The index of Katz at the admission was 3.96 and the Parker index was 6.56. The mortality in the hospital was of 30 patients (11%). The following during six months was in 114 patients of the people that were operated; we found loss of initial reduction the hip fracture in 10% and infection in 4%

  15. Pathogenesis of osteoporotic hip fractures.

    Science.gov (United States)

    McClung, Michael R

    2003-01-01

    Osteoporosis is characterized late in the course of the disease by an increased risk of fracture, particularly in the elderly. It occurs in both sexes, affecting approximately 8 million women and 2 million men aged > or = 50 years (1). While low bone density is a predictor of fractures, it is not the only determinant of fracture risk. Other factors include advanced age, altered bone quality, a personal or family history of falls, frailty, poor eyesight, debilitating diseases, and high bone turnover. A diet with sufficient calcium and vitamin D is important to minimize bone loss and, along with regular exercise, to maintain muscle strength. Bisphosphonates have been shown to reduce the risk of hip fracture. For elderly patients, the use of hip protectors may be used as a treatment of last resort. Regardless of the age of the patient, individual patient risk factors must be considered to target appropriate treatment and prevent fracture.

  16. Osteoporotic Hip and Spine Fractures

    OpenAIRE

    Cannada, Lisa K.; Hill, Brian W.

    2014-01-01

    Hip and spine fractures represent just a portion of the burden of osteoporosis; however, these fractures require treatment and often represent a major change in lifestyle for the patient and their family. The orthopedic surgeon plays a crucial role, not only in the treatment of these injuries but also providing guidance in prevention of future osteoporotic fractures. This review provides a brief epidemiology of the fractures, details the surgical techniques, and outlines the current treatment...

  17. Hip arthroscopy for femoroacetabular impingement

    Science.gov (United States)

    Nasser, Rima; Domb, Benjamin

    2018-01-01

    The purpose of this article is to give a general overview of femoroacetabular impingement (FAI) and how it could be treated arthroscopically, with some details about indications, the procedure itself and some of the complications associated with the surgery. FAI is a dynamic condition of the hip that can be a source of pain and disability and could potentially lead to arthritis. When symptomatic, and if conservative treatment fails, FAI can be addressed surgically. The goal of surgical treatment for FAI is to recreate the spherical contour of the femoral head, improve femoral offset, normalize coverage of the acetabulum, repair/reconstruct chondral damage and repair/reconstruct the labrum to restore normal mechanics and joint sealing. Advances in equipment and technique have contributed to an increase in the number of hip arthroscopy procedures performed worldwide and have made it one of the more common treatment options for symptomatic FAI. Hip arthroscopy is a procedure with an extremely steep and long learning curve. Cite this article: EFORT Open Rev 2018;3:121-129. DOI: 10.1302/2058-5241.3.170041 PMID:29780619

  18. [Technology of cementless hip endoprosthetics].

    Science.gov (United States)

    Ungethüm, M; Blömer, W

    1987-06-01

    The success achieved with non-cemented hip arthroplasty depends mainly on the stability of the fixation, the quality of the stabilizing bone being just as important as favourable biomechanical conditions. The results of the intensive research and development with respect to the particular features of a non-cemented hip endoprosthesis can be divided into the following basic categories: Biomechanical aspects with special reference to bone related to the design of the prosthesis; material characteristics, such as fatigue strength, tribology, corrosion resistance, and biocompatibility; and development of new materials and coatings to permit direct bonding of implant and bone. With regard to the stem of hip prostheses, the different design parameters of various types are examined to determine their typical design characteristics, such as bearing surface of the collar, geometry of cross section, anatomically adapted shaping, and surface of the implant forming the contact with the bone. The latter can be divided into macroprofiles and macro- and micro-porous coated surfaces. On the other hand, the methods of cementless fixation of acetabular cups can be primarily divided into conical and spherical screw fixation and pegged fixation with additional macroprofiles of porous surfaces. In a separate study of the biomechanical aspects of screwed sockets, the special importance of socket shape and thread geometry are presented with reference to primary stability and long-term fixation of prostheses.

  19. A Hip Implant Energy Harvester

    Science.gov (United States)

    Pancharoen, K.; Zhu, D.; Beeby, S. P.

    2014-11-01

    This paper presents a kinetic energy harvester designed to be embedded in a hip implant which aims to operate at a low frequency associated with body motion of patients. The prototype is designed based on the constrained volume available in a hip prosthesis and the challenge is to harvest energy from low frequency movements (< 1 Hz) which is an average frequency during free walking of a patient. The concept of magnetic-force-driven energy harvesting is applied to this prototype considering the hip movements during routine activities of patients. The magnetic field within the harvester was simulated using COMSOL. The simulated resonant frequency was around 30 Hz and the voltage induced in a coil was predicted to be 47.8 mV. A prototype of the energy harvester was fabricated and tested. A maximum open circuit voltage of 39.43 mV was obtained and the resonant frequency of 28 Hz was observed. Moreover, the power output of 0.96 μW was achieved with an optimum resistive load of 250Ω.

  20. A Hip Implant Energy Harvester

    International Nuclear Information System (INIS)

    Pancharoen, K; Zhu, D; Beeby, S P

    2014-01-01

    This paper presents a kinetic energy harvester designed to be embedded in a hip implant which aims to operate at a low frequency associated with body motion of patients. The prototype is designed based on the constrained volume available in a hip prosthesis and the challenge is to harvest energy from low frequency movements (< 1 Hz) which is an average frequency during free walking of a patient. The concept of magnetic-force-driven energy harvesting is applied to this prototype considering the hip movements during routine activities of patients. The magnetic field within the harvester was simulated using COMSOL. The simulated resonant frequency was around 30 Hz and the voltage induced in a coil was predicted to be 47.8 mV. A prototype of the energy harvester was fabricated and tested. A maximum open circuit voltage of 39.43 mV was obtained and the resonant frequency of 28 Hz was observed. Moreover, the power output of 0.96 μW was achieved with an optimum resistive load of 250Ω

  1. Planetary Suit Hip Bearing Model for Predicting Design vs. Performance

    Science.gov (United States)

    Cowley, Matthew S.; Margerum, Sarah; Harvil, Lauren; Rajulu, Sudhakar

    2011-01-01

    Designing a planetary suit is very complex and often requires difficult trade-offs between performance, cost, mass, and system complexity. In order to verifying that new suit designs meet requirements, full prototypes must eventually be built and tested with human subjects. Using computer models early in the design phase of new hardware development can be advantageous, allowing virtual prototyping to take place. Having easily modifiable models of the suit hard sections may reduce the time it takes to make changes to the hardware designs and then to understand their impact on suit and human performance. A virtual design environment gives designers the ability to think outside the box and exhaust design possibilities before building and testing physical prototypes with human subjects. Reductions in prototyping and testing may eventually reduce development costs. This study is an attempt to develop computer models of the hard components of the suit with known physical characteristics, supplemented with human subject performance data. Objectives: The primary objective was to develop an articulating solid model of the Mark III hip bearings to be used for evaluating suit design performance of the hip joint. Methods: Solid models of a planetary prototype (Mark III) suit s hip bearings and brief section were reverse-engineered from the prototype. The performance of the models was then compared by evaluating the mobility performance differences between the nominal hardware configuration and hardware modifications. This was accomplished by gathering data from specific suited tasks. Subjects performed maximum flexion and abduction tasks while in a nominal suit bearing configuration and in three off-nominal configurations. Performance data for the hip were recorded using state-of-the-art motion capture technology. Results: The results demonstrate that solid models of planetary suit hard segments for use as a performance design tool is feasible. From a general trend perspective

  2. Gait symmetry and hip strength in women with developmental dysplasia following hip arthroplasty compared to healthy subjects: A cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Ruud A Leijendekkers

    Full Text Available Untreated unilateral developmental dysplasia of the hip (DDH results in asymmetry of gait and hip strength and may lead to early osteoarthritis, which is commonly treated with a total hip arthroplasty (THA. There is limited knowledge about the obtained symmetry of gait and hip strength after the THA. The objectives of this cross-sectional study were to: a identify asymmetries between the operated and non-operated side in kinematics, kinetics and hip strength, b analyze if increased walking speed changed the level of asymmetry in patients c compare these results with those of healthy subjects.Women (18-70 year with unilateral DDH who had undergone unilateral THA were eligible for inclusion. Vicon gait analysis system was used to collect frontal and sagittal plane kinematic and kinetic parameters of the hip joint, pelvis and trunk during walking at comfortable walking speed and increased walking speed. Furthermore, hip abductor and extensor muscle strength was measured.Six patients and eight healthy subjects were included. In the patients, modest asymmetries in lower limb kinematics and kinetics were present during gait, but trunk lateral flexion asymmetry was evident. Patients' trunk lateral flexion also differed compared to healthy subjects. Walking speed did not significantly influence the level of asymmetry. The hip abduction strength asymmetry of 23% was not statistically significant, but the muscle strength of both sides were significantly weaker than those of healthy subjects.In patients with a DDH treated with an IBG THA modest asymmetries in gait kinematics and kinetics were present, with the exception of a substantial asymmetry of the trunk lateral flexion. Increased walking speed did not result in increased asymmetries in gait kinematics and kinetics. Hip muscle strength was symmetrical in patients, but significantly weaker than in healthy subjects. Trunk kinematics should be included as an outcome measure to assess the biomechanical

  3. Segmental blood pressure after total hip replacement

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Soelberg, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Twenty-nine patients due to have a total hip replacement had their systemic systolic and segmental blood pressures measured prior to operation and 1 and 6 weeks postoperatively. No patients had signs of ischemia. The segmental blood pressure was measured at the ankle and at the toes. A significant...... drop was found in all pressures 1 week postoperatively. The decrease followed the systemic pressure and was restored to normal after 6 weeks. In a group of six patients with preoperatively decreased ankle pressure, a significant transient further decrease in the ankle-toe gradient pressure was found...... on the operated side. None of the patients had symptoms from the lowered pressure. We conclude that in patients without signs of ischemia, the postoperative segmental pressure decrease is reversible and therefore not dangerous....

  4. Cost-effectiveness of hip protectors in frail institutionalized elderly

    NARCIS (Netherlands)

    van Schoor, N.M.; de Bruyne, M.C.; van der Roer, N.; Lommerse, E.; van Tulder, M.; Bouter, L.M.; Lips, P.T.A.M.

    2004-01-01

    A randomized controlled trial was performed to examine the cost-effectiveness of external hip protectors in the prevention of hip fractures. Since the hip protectors were not effective in preventing hip fractures in our study, the main objective became to examine whether the use of hip protectors

  5. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain

    DEFF Research Database (Denmark)

    Rafn, Bolette S; Tang, Lars; Nielsen, Peter Martin

    2016-01-01

    OBJECTIVE: To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. DESIGN: Cross-sectional study. SETTING: Clinical assessments at Sports Orthopaedic Research...... Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. PARTICIPANTS: Twenty-four male soccer players with unilateral long-standing hip and groin pain. INTERVENTIONS: The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion...... strength (Spearman rho = -0.44, P = 0.016). CONCLUSIONS: Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain....

  6. Kinematic relationship between rotation of lumbar spine and hip joints during golf swing in professional golfers.

    Science.gov (United States)

    Mun, Frederick; Suh, Seung Woo; Park, Hyun-Joon; Choi, Ahnryul

    2015-05-14

    Understanding the kinematics of the lumbar spine and hip joints during a golf swing is a basic step for identifying swing-specific factors associated with low back pain. The objective of this study was to examine the kinematic relationship between rotational movement of the lumbar spine and hip joints during a golf swing. Fifteen professional golfers participated in this study with employment of six infrared cameras to record their golf swings. Anatomical reference system of the upper torso, pelvis and thigh segments, and the location of each hip and knee joint were defined by the protocols of the kinematic model of previous studies. Lumbar spine and hip joint rotational angle was calculated utilizing the Euler angle method. Cross-correlation and angle-angle plot was used to examine the degree of kinematic relationship between joints. A fairly strong coupling relationship was shown between the lumbar spine and hip rotational movements with an average correlation of 0.81. Leading hip contribution to overall rotation was markedly high in the early stage of the downswing, while the lumbar spine contributed greater towards the end of the downswing; however, the relative contributions of the trailing hip and lumbar spine were nearly equal during the entire downswing. Most of the professional golfers participated in this study used a similar coordination strategy when moving their hips and lumbar spine during golf swings. The rotation of hips was observed to be more efficient in producing the overall rotation during the downswing when compared to the backswing. These results provide quantitative information to better understand the lumbar spine and hip joint kinematic characteristics of professional golfers. This study will have great potential to be used as a normal control data for the comparison with kinematic information among golfers with low back pain and for further investigation of golf swing-specific factors associated with injury.

  7. Imaging findings of anterior hip dislocations

    Energy Technology Data Exchange (ETDEWEB)

    Pfeifer, Kyle [Mallinckrodt Institute of Radiology, Department of Radiology, St. Louis, MO (United States); Leslie, Michael [Yale School of Medicine, Department of Orthopedics and Rehabilitation, New Haven, CT (United States); Menn, Kirsten; Haims, Andrew [Yale University School of Medicine, Department of Radiology and Biomedical Imaging, New Haven, CT (United States)

    2017-06-15

    Anterior hip dislocations are rare orthopedic emergencies resulting from high-energy trauma and have unique imaging characteristics on radiography, computed tomography (CT), and magnetic resonance imaging (MRI). Imaging findings on CT and MRI allow for the prompt recognition and classification of anterior hip dislocations, which guides patient management and reduces complications. The purpose of this article is to review imaging findings of anterior hip dislocations, specifically focusing on CT and MRI. (orig.)

  8. Hip biomechanics during stair ascent and descent in people with and without hip osteoarthritis.

    Science.gov (United States)

    Hall, Michelle; Wrigley, Tim V; Kean, Crystal O; Metcalf, Ben R; Bennell, Kim L

    2017-07-01

    Hip osteoarthritis (OA) is often associated with pain and impaired function. Understanding biomechanical alterations in patients with hip OA during challenging activities such as stair use is important to inform treatments. The aim of this study was to determine whether kinematics and kinetics during stair ambulation differed between people with hip OA and healthy controls. Fifteen participants with symptomatic and radiographic hip OA and 15 asymptomatic healthy controls underwent 3-D motion analysis during stair ascent and descent. Trunk, pelvis, and hip kinematics as well as hip kinetics were evaluated. Analyses were performed unadjusted and adjusted for speed and leg length. In both the unadjusted and adjusted analyses, participants with hip OA ascended stairs with less hip range of motion in all three planes and a lower peak external rotation moment compared to controls. In the unadjusted analysis, hip OA participants descended stairs with greater ipsilateral trunk lean, less sagittal plane range of motion, lower peak extension moment, lower peak external rotation moment, and greater hip adduction moment impulse compared to controls. In the adjusted results, peak internal rotation moment and hip adduction moment impulse were greater in hip OA participants compared to controls. Findings show that individuals with hip OA display limited range of hip joint movement, particularly during stair ascent, and overall indicate the use of strategies (e.g., trunk lean; lower peak external rotation moment; higher adduction moment impulse) that implicate altered hip abductor function. Future research is required to further understand the implications of these findings on hip OA. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1505-1514, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  9. Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    van Raaij Jos JAM

    2008-10-01

    Full Text Available Abstract Background Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation. Methods A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA, serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score, physician reported functional status and range of motion (Harris hip score, number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years. Discussion

  10. COMPLEX FUNCTIONAL ASSESSMENT OF THE HIP JOINT.

    Directory of Open Access Journals (Sweden)

    Maya S. Krastanova

    2015-09-01

    Full Text Available Introduction: In relation to the study reporting the effects of applying phased complex rehabilitation in patients with total hip arthroplasty, it has been concluded that the everyday clinical practice in Bulgaria does not apply complex examination, giving an objective picture about the extent of functional status of patients with trauma and diseases of the hip. Aim: The main goal of this report is to present a test which incorporates all known and routine research and in which the total number of points determines the functional status of patients with trauma and diseases of the hip. Material and Methods: Based on the Hip dysfunction and Osteoarthritis Outcome Score, the Harris Hip Score modified test, scale D’Aubigne and Postel and Iowa’s test for complex functional evaluation of the hip joint, we have developed a test including information about the degree of pain; goniometry and manual muscle testing of the hip; locomotor test – type of gait and adjuvants; test for Daily Activities of Life. The test has been developed on the basis of expert assessment by doctors and physiotherapists of the proposed indicators for evaluation and determination of the weighting factors’ contribution to the general condition of the patient. Conclusion: The developed and tested method of complex functional assessment of the hip joint enables our colleagues, dealing with trauma and diseases of the hip, to use it in various research and scientific projects, as well as in general medical practice.

  11. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2015-07-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  12. Hip dislocations after 2,734 elective unilateral fast-track total hip arthroplasties

    DEFF Research Database (Denmark)

    Jørgensen, Christoffer Calov; Kjærsgaard-Andersen, Per; Kehlet, Henrik

    2014-01-01

    STUDY DESIGN: Retrospective review of prospectively collected data. OBJECTIVE: To investigate the incidence of hip dislocation 90 days after total hip arthroplasty in relation to time after surgery, mechanism of dislocation and predisposing factors. METHODS: Prospective data on preoperative patient.......31-3.40)] but not hospital stay of hip...

  13. Resolving controversies in hip fracture care: the need for large collaborative trials in hip fractures

    NARCIS (Netherlands)

    Bhandari, Mohit; Sprague, Sheila; Schemitsch, Emil H.; Einhorn, Thomas; Guyatt, Gordon H.; Haidukewych, George; Keating, John; Koval, Kenneth; Rosen, Clifford; Swiontkowski, Marc; Tornetta, Paul; Walter, Stephen D.; Motsitsi, Silas; Pei, Fuxing; Yang, Tian-fu; Zhou, Zong-ke; Arora, Shobha; Babhulkar, Sushrut; Bhargava, Rakesh; Desai, Mohan M.; Dhillon, Mandeep S.; Gill, Harpreet Singh; Goel, S. C.; Reddy, A. V. Gurava; Jain, Anil K.; Kalore, Niraj V.; Kammatkar, Nitin; Kumar, Vijay; Malhorta, Rajesh; Marthandam, S. S. K.; Pankaj, Amite; Patinharayil, Gopinathan; Rai, B. Sachidanand; Ramteke, Alankar Ambadas; Sancheti, Parag K.; Thakkar, Navin N.; Thomas, George S.; Robinson, Dror; Steinberg, Ely; Higuchi, Fujio; Kawamura, Sumito; Ohashi, Hirotsugu; Sawaguchi, Takeshi; Park, Myung-Sik; Yun, Ho Hyun; Poduval, Murali; Siddiqui, Ahmed; Chang, Je-Ken; Wang, Gwo-Jaw; Goslings, J. Carel

    2009-01-01

    Hip fractures are a significant cause of morbidity and mortality worldwide and the burden of disability associated with hip fractures globally vindicate the need for high-quality research to advance the care of patients with hip fractures. Historically, large, multi-centre randomized controlled

  14. Influence of hip dysplasia on the development of osteoarthritis of the hip

    NARCIS (Netherlands)

    A.M. Lievense (Annet); S.M. Bierma-Zeinstra (Sita); A.P. Verhagen (Arianne); J.A.N. Verhaar (Jan); B.W. Koes (Bart)

    2004-01-01

    textabstractBackground: It has been suggested that in some patients with primary hip osteoarthritis (OA), the disease occurs as a consequence of acetabular dysplasia or hip dysplasia (HD). Objective: To carry out a systematic review to investigate the association between acetabular dysplasia and hip

  15. THE NATURE OF THE HYPER-RUNAWAY CANDIDATE HIP 60350

    International Nuclear Information System (INIS)

    Irrgang, Andreas; Przybilla, Norbert; Heber, Ulrich; Fernanda Nieva, M.; Schuh, Sonja

    2010-01-01

    Young, massive stars in the Galactic halo are widely supposed to be the result of an ejection event from the Galactic disk forcing some stars to leave their place of birth as so-called runaway stars. Here, we present a detailed spectroscopic and kinematic analysis of the runaway B star HIP 60350 to determine which runaway scenario-a supernova explosion disrupting a binary system or dynamical interaction in star clusters-may be responsible for HIP 60350's peculiar orbit. Based on a non-local thermodynamic equilibrium approach, a high-resolution optical echelle spectrum was examined to revise spectroscopic quantities and for the first time to perform a differential chemical abundance analysis with respect to the B-type star 18 Peg. The results together with proper motions from the Hipparcos Catalog further allowed the three-dimensional kinematics of the star to be studied numerically. The abundances derived for HIP 60350 are consistent with a slightly supersolar metallicity agreeing with the kinematically predicted place of birth ∼6 kpc away from the Galactic center. However, they do not exclude the possibility of an α-enhanced abundance pattern expected in the case of the supernova scenario. Its outstanding high Galactic rest-frame velocity of 530 ± 35 km s -1 is a consequence of ejection in the direction of Galactic rotation and slightly exceeds the local Galactic escape velocity in a standard Galactic potential. Hence, HIP 60350 may be unbound to the Galaxy.

  16. Surgical hip dislocation for treatment of cam femoroacetabular impingement

    Directory of Open Access Journals (Sweden)

    Milind M Chaudhary

    2015-01-01

    Conclusion: Cam femoroacetabular Impingement causing pain and limitation of hip movements was treated by open osteochondroplasty after surgical hip dislocation. This reduced pain, improved hip motion and gave good to excellent results in the short term.

  17. Comparison of the responsiveness of the Harris Hip Score with generic measures for hip function in osteoarthritis of the hip.

    NARCIS (Netherlands)

    Hoeksma, H.L.; Ende, C.H.M. van den; Ronday, H.K.; Heering, A.; Breedveld, F.C.; Dekker, J.

    2003-01-01

    OBJECTIVE: To compare responsiveness of the Harris Hip Score with generic measures (that is, the Short Form-36 (SF-36), and a test of walking speed and pain during walking) in patients with osteoarthritis (OA) of the hip. METHOD: The first 75 cases within the population of a randomised clinical

  18. Unilateral hip osteoarthritis: can we predict the outcome of the other hip?

    International Nuclear Information System (INIS)

    Vossinakis, I.C.; Georgiades, G.; Hartofilakidis, G.; Kafidas, D.

    2008-01-01

    The objective of this study was to define, in unilateral hip osteoarthritis (OA), factors predicting the outcome of the other hip. We examined the anteroposterior radiographs of the pelvis of 95 white patients with unilateral idiopathic (56 patients) or secondary to congenital hip diseases (39 patients) OA. The other hip was free from symptoms (pain or limping) at the initial examination and without radiographic evidence of OA; it was what we call a ''normal'' hip. Two parameters were evaluated: (1) the type of osteoarthritis of the involved hip and (2) the range of four radiographic indices of the contralateral hip: the sourcil inclination (weight-bearing surface), the acetabular angle, the Wiberg's center-edge angle, and the neck-shaft angle. Follow-up radiographs for the hips that remained OA-free were available for 10 to 35 years and for those that developed OA, at the time of initial symptoms, range 2 to 31 years. Logistic regression analysis showed that the presence of idiopathic OA in one hip had a statistically significant effect on the development of OA on the other hip (p<0.001). Minor deviations of radiographic indices of the contralateral hip is not a predictive factor for its outcome. When the radiographic indices are examined together with the pathology of the involved hip, only WBS was shown to have a significant effect to the development of OA and its type (p < 0.001). The following conclusions can be drawn from this study: 1. Patient with idiopathic OA of one hip is at increased risk of developing OA in the other hip. 2. The outcome of the other hip cannot be predicted only on the basis of the evaluation of its radiographic indices. 3. Among the different indices, WBS seems to have a strong influence toward the development of OA. (orig.)

  19. Fasilitas Pelatihan dan Pergelaran Seni Tari Hip Hop di Surabaya

    OpenAIRE

    Yanuar, Sandy

    2014-01-01

    Fasilitas Pelatihan dan Pergelaran Seni Tari Hip Hop di Surabaya merupakan fasilitas yang disediakan bagi semua penari Hip Hop di Surabaya untuk berlatih menari dan mempertunjukan tarian Hip Hop. Fasilitas ini tersedia bagi semua penari Hip Hop termasuk penari difable, mengingat kaum difable juga dapat menari Hip Hop. Namun karena di Surabaya belum memiliki fasilitas yang memadai bagi semua penari Hip Hop termasuk penari difable untuk menari dan memiliki tempat pertunjukan yang berkarakter Hi...

  20. Conversion total hip arthroplasty: Primary or revision total hip arthroplasty

    Science.gov (United States)

    Schwarzkopf, Ran; Baghoolizadeh, Mahta

    2015-01-01

    Total hip arthroplasty (THA) is an increasingly common procedure among elderly individuals. Although conversion THA is currently bundled in a diagnosis related group (DRG) with primary THA, there is a lack of literature supporting this classification and it has yet to be identified whether conversion THA better resembles primary or revision THA. This editorial analyzed the intraoperative and postoperative factors and functional outcomes following conversion THA, primary THA, and revision THA to understand whether the characteristics of conversion THA resemble one procedure or the other, or are possibly somewhere in between. The analysis revealed that conversion THA requires more resources both intraoperatively and postoperatively than primary THA. Furthermore, patients undergoing conversion THA present with poorer functional outcomes in the long run. Patients undergoing conversion THA better resemble revision THA patients than primary THA patients. As such, patients undergoing conversion THA should not be likened to patients undergoing primary THA when determining risk stratification and reimbursement rates. Conversion THA procedures should be planned accordingly with proper anticipation of the greater needs both in the operating room, and for in-patient and follow-up care. We suggest that conversion THA be reclassified in the same DRG with revision THA as opposed to primary THA as a step towards better allocation of healthcare resources for conversion hip arthroplasties. PMID:26601055

  1. STUDY OF FUNCTIONAL RESULTS OF CEMENTED TOTAL HIP REPLACEMENT BY MOORE’S APPROACH

    Directory of Open Access Journals (Sweden)

    Arunim

    2016-02-01

    Full Text Available INTRODUCTION The total hip replacement (THR has probably become the surgical procedure of choice for vide variety of hip joint disabling diseases. The prosthesis used for THR is often grouped into cemented, cement-less and hybrid ones. There has been increasing trends in use of cement-less components citing more number of complications namely loosening, increased infection rate etc. however with additional cost factors as well. We conducted this study to ascertain whether in a developing country like ours should we really switch over to un-cemented hip replacements dreading such complications or can we still use cemented prosthesis with equally good if not better results. METHODS A study of functional results of cemented total hip replacement was done in patients with varied age groups ranging from 40 years to 75 years with the average age being 54.8 years. 20 patients with 21 diseased hips were treated with cemented total hip replacement by Moore’s posterior approach at NSCB Subharti medical college, Meerut, UP from December 2010 to December 2013 and reviewed thereafter with an average follow-up period of 4.2 years. Average surgical time required was one and half hour. Patients were asked to come for follow up on 1st month, 3rd month and 6th month and then every 6 months and were assessed as per modified Harris Hip Score. RESULTS All the patients were evaluated according to the Modified Harris Hip Scoring system. The results showed 14(67% hips with excellent results, 4(19% with good results, and 3(14% hips with fair results. No poor outcome was noted in this study. 2 cases of dislocation (10% were noted one on the 5th post-operative day and the other occurred after the patient was discharged from the institution. CONCLUSIONS The management of diseased and destroyed hips with chronic pain with cemented total hip replacement is effective and gives stable, mobile and painless hip joint to the patient. Functional results are excellent and

  2. Outcomes After Diagnostic Hip Injection.

    Science.gov (United States)

    Lynch, T Sean; Steinhaus, Michael E; Popkin, Charles A; Ahmad, Christopher S; Rosneck, James

    2016-08-01

    To provide a comprehensive review of outcomes associated with local anesthetic (LA) or LA and corticosteroid (CS) diagnostic hip injections, and how well response predicts subsequent operative success. A systematic review from database (PubMed, Medline, Scopus, Embase) inception to January 2015 for English-language articles reporting primary patient outcomes data was performed, excluding studies with >50% underlying osteoarthritis. Studies were assessed by 2 reviewers who collected pertinent data. Seven studies were included, reporting on a total 337 patients undergoing diagnostic hip injection. The mean age was 34.4 years, with 5 studies reporting 94 (35.2%) males and 173 (64.8%) females. One study examined the rate of pain relief with LA (92.5%); 2 CS studies reported relief on a scale from 0% to 100% (no to complete relief), ranging from 61% to 82.3%; and 3 studies used 10-point pain scales, with a CS study noting a pain score of 1.0, an LA study with a score of 3.03, and 1 study using either CS or LA scores of 3 to 5.6. Duration of pain relief was 9.8 (CS) and 2.35 days (LA). By pathology, greatest relief was achieved in acetabular chondral injury (93.3%) and least in cam impingement (81.6%), with clinical and imaging findings being unreliable predictors of relief. One study showed nonresponse to be a strong predictor of negative surgical outcome for femoroacetabular impingement. Diagnostic hip injections provide substantial pain relief for patients with various hip pathologies, with limited data to suggest greatest relief for those with chondral injury. Clinical and imaging findings are unreliable predictors of injection response, and nonresponse to injection is a strong negative predictor of surgical outcome. Future research should focus on elucidating differences by underlying pathology and predicting future operative success. Level IV, systematic review. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights

  3. Danish Hip Arthroscopy Registry (DHAR)

    DEFF Research Database (Denmark)

    Lund, Bent; Mygind-Klavsen, Bjarne; Grønbech Nielsen, Torsten

    2017-01-01

    The Danish Hip Arthroscopy Registry (DHAR) was initiated in January 2012 as a web-based prospective registry. The purpose of this study was to evaluate and report the first registry based outcome data of a national population with radiological and clinical femoroacetabular impingement (FAI......) data from DHAR between January 2012 and November 2015 were extracted. Radiological pincer-type FAI was defined as LCE > 35° and cam FAI as alpha-angle > 55°. These data were combined with FAI surgical data such as osteochondroplasty and labral repair or resection. PROMs consisting of HAGOS, EQ-5 D...

  4. Kinematic analysis of hip and knee rotation and other contributors to ballet turnout.

    Science.gov (United States)

    Quanbeck, Amy E; Russell, Jeffrey A; Handley, Sara C; Quanbeck, Deborah S

    2017-02-01

    Turnout, or external rotation (ER) of the lower extremities, is essential in ballet. The purpose of this study was to utilise physical examination and a biomechanical method for obtaining functional kinematic data using hip and knee joint centres to identify the relative turnout contributions from hip rotation, femoral anteversion, knee rotation, tibial torsion, and other sources. Ten female dancers received a lower extremity alignment assessment, including passive hip rotation, femoral anteversion, tibial torsion, weightbearing foot alignment, and Beighton hypermobility score. Next, turnout was assessed using plantar pressure plots and three-dimensional motion analysis; participants performed turnout to ballet first position on both a plantar pressure mat and friction-reducing discs. A retro-reflective functional marker motion capture system mapped the lower extremities and hip and knee joint centres. Mean total turnout was 129±15.7° via plantar pressure plots and 135±17.8° via kinematics. Bilateral hip ER during turnout was 49±10.2° (36% of total turnout). Bilateral knee ER during turnout was 41±5.9° (32% of total turnout). Hip ER contribution to total turnout measured kinematically was less than expected compared to other studies, where hip ER was determined without functional kinematic data. Knee ER contributed substantially more turnout than expected or previously reported. This analysis method allows precise assessment of turnout contributors.

  5. TREATMENT OF NEUROLOGICAL CONGENITAL HIP LUXATION

    Directory of Open Access Journals (Sweden)

    Iulian ICLEANU

    2015-11-01

    Full Text Available Congenital hip luxation is a disorder which evolves in time. Teratological hip dislocation is a distinct form of hip luxation, which usually appears with other disorders. These hips are dislocated before birth. In this thesis we will try to elaborate a recovery program, through physical exercises, which will help us realize our treatment objectives: diminishing articular stiffness, increasing articular mobility, increasing muscle strength, recalibration of agonist and antagonist balances and reeducating gait. The specific objectives of the study consist of the particularization of the recovery programs based on age, illness stage (dysplasia or luxation and either surgical or non-surgical intervention. To show the importance of physiotherapy in gait rehabilitation of a child with hip dislocation we started from the hypothesis: using an adequate rehabilitation program after an individualized methodology, optimizes the functional recovery and ensures the gains of hip stability and the formation of an engram of gait as close as it could be to the normal one. We present a case of neurological congenital hip dislocation where the treatment initiated early is showing good results. Results obtained are significantly different and we came to the conclusion that starting an untimely analytical kinetic treatment and globally personalizing it to every patient has better biomechanical results for the hip.

  6. Maximum potential preventive effect of hip protectors

    NARCIS (Netherlands)

    van Schoor, N.M.; Smit, J.H.; Bouter, L.M.; Veenings, B.; Asma, G.B.; Lips, P.T.A.M.

    2007-01-01

    OBJECTIVES: To estimate the maximum potential preventive effect of hip protectors in older persons living in the community or homes for the elderly. DESIGN: Observational cohort study. SETTING: Emergency departments in the Netherlands. PARTICIPANTS: Hip fracture patients aged 70 and older who

  7. Simultaneous and staged bilateral total hip arthroplasty

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Joergensen, Christoffer Calov; Husted, Henrik

    2013-01-01

    Bilateral total hip arthroplasty (BTHA) and bilateral simultaneous total hip arthroplasty (BSTHA) are done increasingly. Previous studies evaluating outcomes after bilateral procedures have found different results. The aim of this study was to investigate length of hospital stay (LOS), 30 days...

  8. CT and MRI of hip arthroplasty

    International Nuclear Information System (INIS)

    Cahir, J.G.; Toms, A.P.; Marshall, T.J.; Wimhurst, J.; Nolan, J.

    2007-01-01

    Plain films are the initial imaging method of choice for evaluation of hip arthroplasty. Recent advances in technology and imaging techniques have largely overcome the problems of beam hardening in computed tomography (CT) and magnetic susceptibility artefact in magnetic resonance imaging (MRI). CT and MRI have now become useful imaging techniques in the assessment of hip arthroplasty

  9. Pressure ulcer risk in hip fracture patients

    NARCIS (Netherlands)

    Houwing, R. H.; Rozendaal, M; Wouters-Wesseling, W; Buskens, E.; Keller, P; Haalboom, JRE

    Hip fracture patients have a high risk of pressure ulcers (PU). We followed 121 hip fracture patients for the development of pressure ulcers and evaluated a risk assessment tool for sensitivity and specificity. More than half of the patients presented with PU, mostly stage I. Risk factors for PU

  10. Total hip arthroplasty for giant cell tumour.

    Directory of Open Access Journals (Sweden)

    Kulkarni S

    1996-07-01

    Full Text Available A 32 month follow up of an uncommon case of a Giant Cell Tumour affecting the proximal end of femur is presented. Following a wide excision, the hip was reconstructed using Charnley type of low friction total hip arthroplasty. At a 32 month review, there was no recurrence and the function was good.

  11. Pertunjukan Teater Karo Hip Hop Kontemporer KAI

    Directory of Open Access Journals (Sweden)

    Silvia Anggreni Purba

    2013-11-01

    Pertunjukan Teater Karo Hip Hop Kontemporer KAI. The performance of Karo Theater collaborated with Hip Hop stems from a simple idea to collaborate Karo cultural traditions with popular culture. The performances can be enjoyed without having limitation on the language and culture. The process of combining two different cultures is a form of hybrid culture, and it may occur due to the globalization process. Through the process of deposition of the observations and strong impression, this performance is then brought into the form of Hip Hop as a preferred form which is energetic, personal and global. This performance is part of a modern tragedy with its destructive character which has explored the emotion and has presented it to the audiences. The exploration of Karo cultural tradition and Hip Hop dance as a language of symbols is able to reinforce words. The movement is not revealed by the verbal phrase but is presented through the movement of Hip Hop dance. The interpretation of the legend and texts into movement is carried out through the training process at the laboratory as a searching process and experiment, and afterward can be realized by considering the basic elements of Hip Hop, Karo cultural elements and performance. Karo Hip Hop Theatre is expected to become a preferred aesthetic form of a modern theater without losing its tradition form. Keyword: a contemporary Karo theater, Hip Hop, hybrid culture.

  12. Hip-hop and urban studies

    NARCIS (Netherlands)

    Jaffe, R.

    2014-01-01

    How can urban studies research engage fruitfully with hip-hop? This contribution responds to the essays by David Beer and Martin Lamotte on ‘street music’, urban ethnography and ghettoized communities. It discusses how a social science engagement with hip-hop texts might differ from cultural studies

  13. Mortality Following Periprosthetic Proximal Femoral Fractures Versus Native Hip Fractures.

    Science.gov (United States)

    Boylan, Matthew R; Riesgo, Aldo M; Paulino, Carl B; Slover, James D; Zuckerman, Joseph D; Egol, Kenneth A

    2018-04-04

    The number of periprosthetic proximal femoral fractures is expected to increase with the increasing prevalence of hip arthroplasties. While native hip fractures have a well-known association with mortality, there are currently limited data on this outcome among the subset of patients with periprosthetic proximal femoral fractures. Using the New York Statewide Planning and Research Cooperative System, we identified patients from 60 to 99 years old who were admitted to a hospital in the state with a periprosthetic proximal femoral fracture (n = 1,655) or a native hip (femoral neck or intertrochanteric) fracture (n = 97,231) between 2006 and 2014. Within the periprosthetic fracture cohort, the indication for the existing implant was not available in the data set. We used mixed-effects regression models to compare mortality at 1 and 6 months and 1 year for periprosthetic compared with native hip fractures. The risk of mortality for patients who sustained a periprosthetic proximal femoral fracture was no different from that for patients who sustained a native hip fracture at 1 month after injury (3.2% versus 4.6%; odds ratio [OR], 0.90; 95% confidence interval [CI], 0.68 to 1.19; p = 0.446), but was lower at 6 months (3.8% versus 6.5%; OR, 0.74; 95% CI, 0.57 to 0.95; p = 0.020) and 1 year (9.7% versus 15.9%; OR, 0.71; 95% CI, 0.60 to 0.85; p accounting for age and comorbidities. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  14. Lumbar lordosis angle and trunk and lower-limb electromyographic activity comparison in hip neutral position and external rotation during back squats.

    Science.gov (United States)

    Oshikawa, Tomoki; Morimoto, Yasuhiro; Kaneoka, Koji

    2018-03-01

    [Purpose] To compare the lumbar lordosis angle and electromyographic activities of the trunk and lower-limb muscles in the hip neutral position and external rotation during back squats. [Subjects and Methods] Ten healthy males without severe low back pain or lower-limb injury participated in this study. The lumbar lordosis angle and electromyographic activities were measured using three-dimensional motion-capture systems and surface electrodes during four back squats: parallel back squats in the hip neutral position and external rotation and full back squats in the hip neutral position and external rotation. A paired t-test was used to compare parallel and full back squats measurements in the hip neutral position and external rotation, respectively. [Results] During parallel back squats, the average lumbar lordosis angle was significantly larger in hip external rotation than in the hip neutral position. During full back squats, lumbar erector spinae and multifidus activities were significantly lower in hip external rotation than in the hip neutral position, whereas gluteus maximus activity was significantly higher in hip external rotation than in the hip neutral position. [Conclusion] The back squat in hip external rotation induced improvement of lumbar kyphosis, an increasing of the gluteus maximus activity and a decrease of both lumbar erector spinae and multifidus activities.

  15. Hip fracture in hospitalized medical patients

    Directory of Open Access Journals (Sweden)

    Zapatero Antonio

    2013-01-01

    Full Text Available Abstract Background The aim of the present study is to analyze the incidence of hip fracture as a complication of admissions to internal medicine units in Spain. Methods We analyzed the clinical data of 2,134,363 adults who had been admitted to internal medicine wards. The main outcome was a diagnosis of hip fracture during hospitalization. Outcome measures included rates of in-hospital fractures, length of stay and cost. Results A total of 1127 (0.057% admittances were coded with an in-hospital hip fracture. In hospital mortality rate was 27.9% vs 9.4%; p  Conclusions In-hospital hip fracture notably increased mortality during hospitalization, doubling the mean length of stay and mean cost of admission. These are reasons enough to stress the importance of designing and applying multidisciplinary plans focused on reducing the incidence of hip fractures in hospitalized patients.

  16. [The hip joint in neuromuscular disorders].

    Science.gov (United States)

    Strobl, W M

    2009-07-01

    Physiologic motor and biomechanical parameters are prerequisites for normal hip development and hip function. Disorders of muscle activity and lack of weight bearing due to neuromuscular diseases may cause clinical symptoms such as an unstable hip or reduced range of motion. Disability and handicap because of pain, hip dislocation, osteoarthritis, gait disorders, or problems in seating and positioning are dependent on the severity of the disease, the time of occurrence, and the means of prevention and treatment. Preservation of pain-free and stable hip joints should be gained by balancing muscular forces and by preventing progressive dislocation. Most important is the exact indication of therapeutic options such as movement and standing therapy as well as drugs and surgery.

  17. Hip Resurfacing Arthroplasty and Perioperative Blood Testing

    Directory of Open Access Journals (Sweden)

    Andrew Cook

    2014-01-01

    Full Text Available It is standard practice in many institutions to routinely perform preoperative and postoperative haemoglobin level testing in association with hip joint arthroplasty procedures. It is our observation, however, that blood transfusion after uncomplicated primary hip arthroplasty in healthy patients is uncommon and that the decision to proceed with blood transfusion is typically made on clinical grounds. We therefore question the necessity and clinical value of routine perioperative blood testing about the time of hip resurfacing arthroplasty. We present analysis of perioperative blood tests and transfusion rates in 107 patients undertaking unilateral hybrid hip resurfacing arthroplasty by the senior author at a single institution over a three-year period. We conclude that routine perioperative testing of haemoglobin levels for hip resurfacing arthroplasty procedures does not assist in clinical management. We recommend that postoperative blood testing only be considered should the patient demonstrate clinical signs of symptomatic anaemia or if particular clinical circumstances necessitate.

  18. Hip strength and range of motion

    DEFF Research Database (Denmark)

    Mosler, Andrea B.; Crossley, Kay M.; Thorborg, Kristian

    2017-01-01

    Objectives To determine the normal profiles for hip strength and range of motion (ROM) in a professional football league in Qatar, and examine the effect of leg dominance, age, past history of injury, and ethnicity on these profiles. Design Cross-sectional cohort study. Methods Participants...... values are documented for hip strength and range of motion that can be used as reference profiles in the clinical assessment, screening, and management of professional football players. Leg dominance, recent past injury history and ethnicity do not need to be accounted for when using these profiles...... included 394 asymptomatic, male professional football players, aged 18–40 years. Strength was measured using a hand held dynamometer with an eccentric test in side-lying for hip adduction and abduction, and the squeeze test in supine with 45° hip flexion. Range of motion measures included: hip internal...

  19. [Radiographic appraisal between metal and bone interosculate backfill after total hip arthroplasty with trabecular metal cup].

    Science.gov (United States)

    Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie

    2009-02-15

    To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no

  20. Incidence and direct hospitalisation costs of hip fractures in Vilnius, capital of Lithuania, in 2010

    Directory of Open Access Journals (Sweden)

    Tamulaitiene Marija

    2012-07-01

    Full Text Available Abstract Background Few epidemiological data on hip fractures were previously available in Lithuania. The aim of this study was to estimate the incidence and hospital costs of hip fractures in Vilnius in 2010. Methods Data were collected from the medical charts of all patients admitted to hospitals in Vilnius (population, 548,835 due to new low-energy trauma hip fracture, during 2010. The estimated costs included ambulance transportation and continuous hospitalisation immediately after a fracture, which are covered by the Lithuanian healthcare system. Results The incidence of new low-energy trauma hip fractures was 252 (308 women and 160 men per 100,000 inhabitants of Vilnius aged 50-years or more. There was an exponential increase in the incidence with increasing age. The overall estimated cost of hip fractures in Vilnius was 1,114,292 EUR for the year 2010. The greatest part of the expenditure was accounted for by fractures in individuals aged 65-years and over. The mean cost per case was 2,526.74 EUR, and cost varied depending on the treatment type. Hip replacement did not affect the overall mean costs of hip fracture. The majority of costs were incurred for acute (53% and long-term care (35% hospital stays, while medical rehabilitation accounted for only 12% of the overall cost. The costs of hip fracture were somewhat lower than those found in other European countries. Conclusion The data on incidence and costs of hip fractures will help to assess the importance of interventions to reduce the number of fractures and associated costs.

  1. YouTube provides irrelevant information for the diagnosis and treatment of hip arthritis.

    Science.gov (United States)

    Koller, Ulrich; Waldstein, Wenzel; Schatz, Klaus-Dieter; Windhager, Reinhard

    2016-10-01

    YouTube is increasingly becoming a key source for people to satisfy the need for additional information concerning their medical condition. This study analyses the completeness of accurate information found on YouTube pertaining to hip arthritis. The present study analyzed 133 YouTube videos using the search terms: hip arthritis, hip arthritis symptoms, hip arthritis diagnosis, hip arthritis treatment and hip replacement. Two quality assessment checklists with a scale of 0 to 12 points were developed to evaluate available video content for the diagnosis and the treatment of hip arthritis. Videos were grouped into poor quality (grade 0-3), moderate quality (grade 4-7) and excellent quality (grade 8-12), respectively. Three independent observers assessed all videos using the new grading system and independently scored all videos. Discrepancies regarding the categories were clarified by consensus discussion. For intra-observer reliabilities, grading was performed at two occasions separated by four weeks. Eighty-four percent (n = 112) had a poor diagnostic information quality, 14% (n = 19) a moderate quality and only 2% (n = 2) an excellent quality, respectively. In 86% (n = 114), videos provided poor treatment information quality. Eleven percent (n = 15) of videos had a moderate quality and only 3% (n = 4) an excellent quality, respectively. The present study demonstrates that YouTube is a poor source for accurate information pertaining to the diagnosis and treatment of hip arthritis. These finding are of high relevance for clinicians as videos are going to become the primary source of information for patients. Therefore, high quality educational videos are needed to further guide patients on the way from the diagnosis of hip arthritis to its proper treatment.

  2. Outcomes of Hip Arthroscopy in Competitive Athletes.

    Science.gov (United States)

    Perets, Itay; Hartigan, David E; Chaharbakhshi, Edwin O; Ashberg, Lyall; Ortiz-Declet, Victor; Domb, Benjamin G

    2017-08-01

    To evaluate the minimum 2-year postoperative clinical outcomes and the rate of return to sports in athletes who underwent capsular plication for the treatment of ligamentous laxity and/or borderline dysplasia during hip arthroscopy for the treatment of femoroacetabular impingement and labral pathology. Since 2008, data were prospectively collected on patients who underwent hip arthroscopy for the treatment of femoroacetabular impingement and/or labral tears. Inclusion criteria were as follows: athlete at the high school, collegiate, or professional levels preoperatively, underwent capsular plication, and preoperatively recorded patient-reported outcome scores including modified Harris hip score (mHHS), nonarthritic athletic hip score (NAHS), hip outcome score-sports-specific subscale (HOS-SSS), and visual analog scale (VAS). Exclusion criteria were as follows: 1, and previous hip conditions. Sports activity and competitive levels were collected at a minimum of 2 years postoperatively. Fifty-one hips (49 patients) met the inclusion criteria, and 41 hips (39 patients) had minimum 2-year follow-up (80.4% follow-up). Mean mHHS increased from 67.1 preoperatively to 83.5 (P arthroscopies allowed the patients to return to sports at follow-up. Thirty-four (82.9%) hip arthroscopies allowed the patients to maintain their competitive physical abilities at follow-up. Patient-reported outcomes and VAS in athletes significantly improved at a minimum of 2 years after capsular plication as a part of hip arthroscopy addressing varying pathologies. In addition, most patients returned to sports at similar or higher competitive levels. These results suggest that capsular plication is a favorable treatment option in athletes with ligamentous laxity and/or borderline dysplasia. Level IV, therapeutic case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. Design and Control of a Powered Hip Exoskeleton for Walking Assistance

    OpenAIRE

    Wu, Qingcong; Wang, Xingsong; Du, Fengpo; Zhang, Xiaobo

    2015-01-01

    The wearable powered exoskeleton is a human-robot cooperation system that integrates the strength of a robot with human intelligence. This paper presents the research results into a powered hip exoskeleton (PH-EXOS) designed to provide locomotive assistance to individuals with walking impediments. The Bowden cable actuated exoskeleton has an anthropomorphic structure with six degrees of freedom (DOF) in order to match the human hip anatomy and enable natural interaction with the user. The mec...

  4. Metal-on-Metal Total Hip Resurfacing Arthroplasty

    Science.gov (United States)

    2006-01-01

    Oxford hip scores, but no preoperative values were reported. None of the reviewed studies reported procedure-related deaths. Four studies reported implant survival rates ranging from 94.4% to 99.7% for a follow-up period of 2.8 to 3.5 years. Three studies reported on the range of motion. One reported improvement in all motions including flexion, extension, abduction-adduction, and rotation, and another reported improvement in flexion. Yet another reported improvement in range of motion for flexion abduction-adduction and rotation arc. However, the author reported a decrease in the range of motion in the arc of flexion in patients with Brooker class III or IV heterotopic bone (all patients were men). Safety of Metal-on-Metal Hip Resurfacing Arthroplasty There is a concern about metal wear debris and its systemic distribution throughout the body. Detectable metal concentrations in the serum and urine of patients with metal hip implants have been described as early as the 1970s, and this issue is still controversial after 35 years. Several studies have reported high concentration of cobalt and chromium in serum and/or urine of the patients with metal hip implants. Potential toxicological effects of the elevated metal ions have heightened concerns about safety of MOM bearings. This is of particular concern in young and active patients in whom life expectancy after implantation is long. Since 1997, 15 studies, including 1 randomized clinical trial, have reported high levels of metal ions after THR with metal implants. Some of these studies have reported higher metal levels in patients with loose implants. Adverse Biological Effects of Cobalt and Chromium Because patients who receive a MOM hip arthroplasty are shown to be exposed to high concentrations of metallic ions, the Medical Advisory Secretariat searched the literature for reports of adverse biological effects of cobalt and chromium. Cobalt and chromium make up the major part of the metal articulations; therefore, they

  5. Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur

    OpenAIRE

    Shyam Kumar, A. J.; Parmar, V.; Bankart, J.; Williams, S. C.; Harper, W. M.

    2006-01-01

    This study compared the accuracy of lag screw placement between extracapsular femoral fractures fixed with sliding hip screw plate systems and those fixed with cephalocondylic nails. It involved 75 retrospective radiographs of fractures fixed with either a cephalocondylic nail (32) or a sliding hip screw plate system (43). Postoperative anteroposterior and lateral radiographs of the hip were scanned using a digital X-ray scanner and measured using computer software. Measurements were conducte...

  6. The Role of Hip Arthroscopy in Investigating and Managing the Painful Hip Resurfacing Arthroplasty.

    Science.gov (United States)

    Mei-Dan, Omer; Pascual-Garrido, Cecilia; Moreira, Brett; McConkey, Mark O; Young, David A

    2016-03-01

    To determine the safety and efficacy of hip arthroscopy performed in the peripheral compartment as a diagnostic and therapeutic treatment option for patients with hip pain after hip resurfacing surgery. Indications for hip arthroscopy after hip resurfacing included patients with a symptomatic hip-resurfaced arthroplasties who did not respond to nonoperative treatment. Patients who underwent a hip arthroscopy after a painful hip resurfacing were included with a minimum of 1 year follow-up. Subgroup analysis was performed according to whether an established diagnosis was made before arthroscopic intervention or not. Subjective measures were based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores, and results were calculated and analyzed. We included 68 patients (26 male [38%] and 42 female [62%]) who underwent subsequent hip arthroscopy from a population of 978 consecutive hip-resurfaced arthroplasties performed between 1999 and 2010. The average age was 58 (range, 37 to 78 years). The mean follow-up after hip arthroscopy was 3.4 years (range, 12 months to 5.8 years). Patients who had an established diagnosis (n = 41) before hip arthroscopy showed statistical improvement in their WOMAC scores (7 to 2, P arthroscopy showed statistical worsening of the WOMAC (15 to 21, P = .002). Ten (37%) of these 27 patients without a diagnosis failed and needed to be converted to a THR. A significant correlation was found between the collections found on ultrasound (psoas bursa and/or in the hip joint) and the need for synovectomy (P = .01). The overall revision rate to THR after hip resurfacing in our group of patients was 1.3% (n = 13). Female patients were more likely to require postresurfacing hip arthroscopy with 42 (60%) female to only 26 (40%) male patients undergoing this procedure. In our study population, 70% (14/21, P arthroscopy. Hip arthroscopy is a safe surgical treatment option for those patients with a painful hip resurfacing

  7. Reconstruction of the Acetabulum in Developmental Dysplasia of the Hip in Total Hip Replacement

    Directory of Open Access Journals (Sweden)

    Vasileios Sakellariou

    2014-09-01

    Full Text Available Developmental dysplasia of the hip (DDH or congenital hip dysplasia (CDH is the most prevalent developmental childhood hip disorder. It includes a wide spectrum of hip abnormalities ranging from dysplasia to subluxation and complete dislocation of the hip joint. The natural history of neglected DDH in adults is highly variable. The mean age of onset of symptoms is 34.5 years for dysplastic DDH, 32.5 years for low dislocation, 31.2 years for high dislocation with a false acetabulum, and 46.4 years for high dislocation without a false acetabulum. Thorough understanding of the bony and soft tissue deformities induced by dysplasia is crucial for the success of total hip arthroplasty. It is important to evaluate the existing acetabular deformity three-dimensionally, and customize the correction in accordance with the quantity and location of ace tabular deficiencies. Acetabular reconstruction in patients with DDH is hallenging. Interpretation of published data is difficult and should be done with caution because most series include patients with different types of hip disease. In general, the complication rate associated with THA is higher in patients with hip dysplasia than it is in patients with osteoarthritis. Overall, clinical and functional outcomes following THA in patients hip dysplasia (DDH differ from those treated for primary hip osteoarthritis, possibly due to the lower age and level of activity. Although function scores decline with age, the scores for pain and range of motion presented with a statistically significant improvement in the long-term.

  8. Hip instability: a review of hip dysplasia and other contributing factors

    Science.gov (United States)

    Kraeutler, Matthew J.; Garabekyan, Tigran; Pascual-Garrido, Cecilia; Mei-Dan, Omer

    2016-01-01

    Summary Background Hip instability has classically been associated with developmental dysplasia of the hip (DDH) in newborns and children. However, numerous factors may contribute to hip instability in children, adolescents, and adults. Purpose This review aims to concisely present the literature on hip instability in patients of all ages in order to guide health care professionals in the appropriate diagnosis and treatment of the various disorders which may contribute to an unstable hip. Methods We reviewed the literature on the diagnosis and surgical management of hip dysplasia and other causes of hip instability. Conclusions Multiple intra- and extra-articular variables may contribute to hip instability, including acetabular bony coverage, femoral torsion, femoroacetabular impingement, and soft tissue laxity. Physical examination and advanced imaging studies are essential to accurately diagnose the pathology contributing to a patient’s unstable hip. Conservative management, including activity modification and physical therapy, may be used as a first-line treatment in patients with intra-articular hip pathology. Patients who continue to experience symptoms of pain or instability should proceed with arthroscopic or open surgical treatment aimed at correcting the underlying pathology. Level of evidence V. PMID:28066739

  9. Analysis of hip perfusion at early and reversible stages of aseptic hip necrosis

    International Nuclear Information System (INIS)

    Predic, P.; Dodig, D.; Karner, I.

    2002-01-01

    Aim: A proper early diagnosis of aseptic hip necrosis is very important for further therapy.Since there has always been a question of the amount of perfusion in hips at different stages of aseptic hip necrosis we tried to impartially examine the perfusion in hips at early and reversible stages of aseptic hip necrosis. Material and Methods:Study included 143 patients with aseptic hip necrosis.The 550-740 MBq of Tc-99m-DPD were on bolus injected.All patients were subjected to 3-phase scintigraphy of hips and quantitative calculation of relative perfusion in the artery phase (3T) at early and repeated at reversible stages of aseptic hip necrosis. Results: At the early stage of aseptic hip necrosis the obtained 3T was decreased from 0.94-0.69 (3T=0.80).Scintigrams showed a moderate increase or diffuse accumulation. At the reversible stages we obtained 3T decreased from 0.92-0.71 (3T=0.79) thus evidencing hypoperfusion.Scintigrams showed an diffuse increased accumulation. Conclusion: With the aseptic hip necrosis quantitative analysis of perfusion in the artery phase-3T indicates that the perfusion is decreased at all stages of the process which however shows a significantly falling trend with the progress of the disease

  10. The effects of therapeutic hip exercise with abdominal core activation on recruitment of the hip muscles.

    Science.gov (United States)

    Chan, Mandy Ky; Chow, Ka Wai; Lai, Alfred Ys; Mak, Noble Kc; Sze, Jason Ch; Tsang, Sharon Mh

    2017-07-21

    Core stabilization has been utilized for rehabilitation and prevention of lower limb musculoskeletal injuries. Previous studies showed that activation of the abdominal core muscles enhanced the hip muscle activity in hip extension and abduction exercises. However, the lack of the direct measurement and quantification of the activation level of the abdominal core muscles during the execution of the hip exercises affect the level of evidence to substantiate the proposed application of core exercises to promote training and rehabilitation outcome of the hip region. The aim of the present study was to examine the effects of abdominal core activation, which is monitored directly by surface electromyography (EMG), on hip muscle activation while performing different hip exercises, and to explore whether participant characteristics such as gender, physical activity level and contractile properties of muscles, which is assessed by tensiomyography (TMG), have confounding effect to the activation of hip muscles in enhanced core condition. Surface EMG of bilateral internal obliques (IO), upper gluteus maximus (UGMax), lower gluteus maximus (LGMax), gluteus medius (GMed) and biceps femoris (BF) of dominant leg was recorded in 20 young healthy subjects while performing 3 hip exercises: Clam, side-lying hip abduction (HABD), and prone hip extension (PHE) in 2 conditions: natural core activation (NC) and enhanced core activation (CO). EMG signals normalized to percentage of maximal voluntary isometric contraction (%MVIC) were compared between two core conditions with the threshold of the enhanced abdominal core condition defined as >20%MVIC of IO. Enhanced abdominal core activation has significantly promoted the activation level of GMed in all phases of clam exercise (P recruitment in Clam, HABD and PHE exercises, and this enhancement is correlated with higher physical activity and stiffer hip muscle. Our results suggest the potential application of abdominal core activation for

  11. Trunk and hip biomechanics influence anterior cruciate loading mechanisms in physically active participants.

    Science.gov (United States)

    Frank, Barnett; Bell, David R; Norcross, Marc F; Blackburn, J Troy; Goerger, Benjamin M; Padua, Darin A

    2013-11-01

    Excessive trunk motion and deficits in neuromuscular control (NMC) of the lumbopelvic hip complex are risk factors for anterior cruciate ligament (ACL) injury. However, the relationship between trunk motion, NMC of the lumbopelvic hip complex, and triplanar knee loads during a sidestep cutting task has not been examined. To determine if there is an association between multiplanar trunk motion, NMC of the lumbopelvic hip complex, and triplanar knee loads with ACL injury during a sidestep cutting task. Descriptive laboratory study. The hip and knee biomechanics and trunk motion of 30 participants (15 male, 15 female) were analyzed during a sidestep cutting task using an optoelectric camera system interfaced to a force plate. Trunk and lower extremity biomechanics were calculated from the kinematic and ground-reaction force data during the first 50% of the stance time during the cutting task. Pearson product moment correlation coefficients were calculated between trunk and lower extremity biomechanics. Multiple linear regression analyses were carried out to determine the amount of variance in triplanar knee loading explained by trunk motion and hip moments. A greater internal knee varus moment (mean, 0.11 ± 0.12 N·m/kg*m) was associated with less transverse-plane trunk rotation away from the stance limb (mean, 20.25° ± 4.42°; r = -0.46, P = .011) and a greater internal hip adduction moment (mean, 0.33 ± 0.25 N·m/kg*m; r = 0.83, P < .05). A greater internal knee external rotation moment (mean, 0.11 ± 0.08 N·m/kg*m) was associated with a greater forward trunk flexion (mean, 7.62° ± 5.28°; r = 0.42, P = .020) and a greater hip internal rotation moment (mean, 0.15 ± 0.16 N·m/kg*m; r = 0.59, P = .001). Trunk rotation and hip adduction moment explained 81% (P < .05) of the variance in knee varus moment. Trunk flexion and hip internal rotation moment explained 48% (P < .05) of the variance in knee external rotation moment. Limited trunk rotation displacement

  12. Hip joint mobility in dancers: preliminary report.

    Science.gov (United States)

    Drężewska, Marlena; Gałuszka, Renata; Sliwiński, Zbigniew

    2012-01-01

    The aim of this study was to evaluate the impact of dancing on hip joint mobility and to assess the relationship between active movements of the hips and injuries among dancers, which may be important in planning rehabilitation in this group. The sample comprised 49 dancers (37 women and 12 men) aged 15 to 32 years. The participants were the professional dancers of the Kielce Dance Theatre and members of two youth jazz dance teams from the Kielce Dance Theatre. The active range of motion of the hips was measured in three planes using a goniometer in order to assess the influence of dance training on hip joint mobility. A questionnaire-based survey was also conducted. The range of flexion, extension and external rotation was significantly greater in the group of long-time dancers (p <0.05). There was a significantly greater range of flexion, abduction and external rotation in previously injured hip joints (p<0.05). 1. Injuries to hip joints in dancers may result in increased ranges of motion, which may lead to disturbances of joint stability. 2. Being a long-time dancer and the female gender were associated with an increased range of hip joint motion.

  13. Mechanical Evaluation of Polymer Composite Hip Protectors

    Directory of Open Access Journals (Sweden)

    Jose Daniel Diniz Melo

    2010-01-01

    Full Text Available Hip fractures often result in serious health implications, particularly in the geriatric population, and have been related to long-term morbidity and death. In most cases, these fractures are caused by impact loads in the area of the greater trochanter, which are produced in a fall. This work is aimed at developing hip protectors using composite materials and evaluating their effectiveness in preventing hip fractures under high impact energy (120 J. The hip protectors were developed with an inner layer of energy absorbing soft material and an outer rigid shell of fiberglass-reinforced polymer composite. According to the experimental results, all tested configurations proved to be effective at reducing the impact load to below the average fracture threshold of proximal femur. Furthermore, an addition of Ethylene Vinyl Acetate (EVA to the impacted area of the composite shell proved to be beneficial to increase impact strength of the hip protectors. Thus, composite hip protectors proved to be a viable alternative for a mechanically efficient and cost-effective solution to prevent hip fractures.

  14. Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density. A 2-year RSA and 8-year radiographic follow-up study of 34 patients.

    Science.gov (United States)

    Finnilä, Sami; Moritz, Niko; SvedströM, Erkki; Alm, Jessica J; Aro, Hannu T

    2016-02-01

    Low bone mineral density (BMD) may jeopardize the initial component stability and delay osseointegration of uncemented acetabular cups in total hip arthroplasty (THA). We measured the migration of uncemented cups in women with low or normal BMD. We used radiostereometric analysis (RSA) to measure the migration of hydroxyapatite-coated titanium alloy cups with alumina-on-alumina bearings in THA of 34 female patients with a median age of 64 (41-78) years. 10 patients had normal BMD and 24 patients had low systemic BMD (T-score ≤ -1) based on dual-energy X-ray absorptiometry (DXA). Cup migration was followed with RSA for 2 years. Radiographic follow-up was done at a median of 8 (2-10) years. Patients with normal BMD did not show a statistically significant cup migration after the settling period of 3 months, while patients with low BMD had a continuous proximal migration between 3 and 12 months (p = 0.03). These differences in cup migration persisted at 24 months. Based on the perceived risk of cup revision, 14 of the 24 cases were "at risk" (proximal translation of 0.2 to 1.0 mm) in the low-BMD group and 2 of the 10 cases were "at risk" in the normal-BMD group (odds ratio (OR) = 8.0, 95% CI: 1.3-48). The radiographic follow-up showed no radiolucent lines or osteolysis. 2 cups have been revised for fractures of the ceramic bearings, but none for loosening. Low BMD contributed to cup migration beyond the settling period of 3 months, but the migrating cups appeared to osseointegrate eventually.

  15. Instability after total hip arthroplasty

    Science.gov (United States)

    Werner, Brian C; Brown, Thomas E

    2012-01-01

    Instability following total hip arthroplasty (THA) is an unfortunately frequent and serious problem that requires thorough evaluation and preoperative planning before surgical intervention. Prevention through optimal index surgery is of great importance, as the management of an unstable THA is challenging even for an experienced joints surgeon. However, even after well-planned surgery, a significant incidence of recurrent instability still exists. Non-operative management is often successful if the components are well-fixed and correctly positioned in the absence of neurocognitive disorders. If conservative management fails, surgical options include revision of malpositioned components; exchange of modular components such as the femoral head and acetabular liner; bipolar arthroplasty; tripolar arthroplasty; use of a larger femoral head; use of a constrained liner; soft tissue reinforcement and advancement of the greater trochanter. PMID:22919568

  16. Risk factors for osteoarthritis of the hip

    Directory of Open Access Journals (Sweden)

    Filipović Karmela

    2013-01-01

    Full Text Available INTRODUCTION: Osteoarthritis of the hip is a degenerative disease of hip unknown origin, with pain, stiffness and diminished joint function. AIM: determine the influence of the load of the hip joint during professional activity and BMI as risk factors for the hip osteoarthritis. MATERIAL AND METHOD: We analysed 148 patients. Patients were divided into two groups ( I group with osteoarthritis of the hip, II group without osteoarthritis of the hip. In all, performed diagnostic procedure: anamnesis, physical examination (estimate of walking and hip joint movement, laboratory blood test and urine test radiological examination and taking data on the height and weight to calculated BMI. We assessed the data that is related to the load of the hip joint during professional activities (mostly sitting work and mostly standing job with carrying load. Statistical analysis was done using the software package SPSS 14.0, Microsoft Office Word 2003. RESULTS: In the first group, average age was 67.76 years, with females prevailing (67.6%. In this group the larger body mass was noted (81.82 ± 12.18, with statistically significant difference (T-test 2.923, p<0.01; the average BMI was higher the average BMI was higher (30.18 ± 4.6, with statistically significant difference (T-test 3.832, p<0.01. This group had more overweight patients (87.7%,with statistically significant difference (Fisher test, p<0.01. In I group 62,2% of patients were doing hard physical work (standing job with repeated carrying load and we found statistically significant difference between groups (Fisher test p<0,01. CONCLUSION: Patients with osteoarthritis of the hip had a higher body weight, higher BMI. Also we found the influence of hard physical labor at work, and they were performed mostly standing job with carrying load.

  17. Romani Music - Roma and the Hip-hop Culture

    OpenAIRE

    Dočkal, Tomáš

    2007-01-01

    This thesis is focused on Romani music and its importance for the Romani culture. It examines the popularity of hip-hop among the young Romani generation and Romani hip- hip production. It attempts to define the role of hip-hop culture in young Romanies' lives.

  18. [Vestibular function, falls and hip fracture in elderly--a relationship study].

    Science.gov (United States)

    Zur, Oz; Carmeli, Eli; Himellfarb, Mordechi; Berner, Yitshal N

    2004-03-01

    Falling is the main reason for which people over 70 arrive at emergency rooms. Over 90% of hip fractures occur as a direct result of falling. To examine the relationship between the function of the vestibular system and hip fractures following falls in elderly. The research group (n = 84) undergone hip surgery as a result of a fall and were then hospitalized in a rehabilitative geriatric care unit at the Meir Hospital in Kfar Sava. The control group (n = 85)--without any history of a hip fracture and living in a retirement home. Four clinical tests were given to each examinee in order to locate any impairment of the vestibular system. Three of the clinical examinations concentrated on testing the VOR while the fourth test was especially used to locate BPPV (Benign Paroxysmal Positional Vertigo). Sociodemographic status and medical history were taken. A significant difference was found between the two groups (those with a hip fracture and those without any hip fracture) with regard to the functioning of the VOR, age, endocrine disease and medications for treating diabetic. However, there was no significant difference found in the appearance of the BPPV. It is important to locate the elderly who are at risk of falling in nursing homes and the community at large by performing the four simple clinical tests. Correct diagnosis and early treatment of the vestibular impairment in elderly patient can prevent the next fall.

  19. Primary total hip replacement for displaced subcapital fractures of the femur.

    Science.gov (United States)

    Taine, W H; Armour, P C

    1985-03-01

    The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.

  20. Routine functional assessment for hip fracture patients

    DEFF Research Database (Denmark)

    Pedersen, Tonny J; Lauritsen, Jens M

    2016-01-01

    Background and purpose - Pre-fracture functional level has been shown to be a consistent predictor of rehabilitation outcomes in older hip fracture patients. We validated 4 overall pre-fracture functional level assessment instruments in patients aged 65 or more, used the prediction of outcome at 4...... months post-fracture, and assessed cutoff values for decision making in treatment and rehabilitation. Patients and methods - 165 consecutive patients with acute primary hip fracture were prospectively included in the study. Pre-fracture Barthel-20, Barthel-100, cumulated ambulation score, and new...... investigation of usage for guidance of clinical and rehabilitation decisions concerning hip fracture patients is warranted....

  1. The hip abductors at MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, A., E-mail: adrienne.hoffmann@balgrist.ch [Department of Radiology, University Hospital Balgrist, Forchstrasse 340, CH-8008 Zürich (Switzerland); Pfirrmann, C.W.A., E-mail: christian.pfirrmann@balgrist.ch [Department of Radiology, University Hospital Balgrist, Forchstrasse 340, CH-8008 Zürich (Switzerland)

    2012-12-15

    Imaging of the hip abductors plays an increasing role for the evaluation of greater trochanteric pain in patients with and without total hip arthroplasty. This review article addresses the anatomy of the hip abductors and their intervening bursae. It highlights different possible imaging appearances such as tendinopathy or partial and full thickness tears of the gluteal tendons. Muscle atrophy or fatty degeneration of the gluteal muscles is an important reason for limping. Inflammatory diseases such as hydroxyapatite crystal deposition disease or spondylarthritis have to be considered. Knowledge of these different entities is important to achieve optimal treatment and outcomes.

  2. Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

    LENUS (Irish Health Repository)

    Brennan, S A

    2009-04-01

    PURPOSE: To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS: 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent uncemented THA using the trident acetabular cup. Obese elderly women at risk of femoral neck fracture and patients with large subchondral pseudocysts or a history of avascular necrosis of the femoral head were assigned to uncemented THA. Acetabular reamings were collected; marginal osteophytes were not included. The reamings were dehydrated, defatted, and weighed. RESULTS: The mean weight of acetabular reamings was not significantly different between patients undergoing hip resurfacing and uncemented THA (p=0.57). CONCLUSION: In hip resurfacing, the use of an appropriately small femoral component avoids oversizing the acetabular component and removal of excessive bone stock.

  3. Hip adduction and abduction strength profiles in elite soccer players

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Serner, Andreas; Petersen, Jesper

    2011-01-01

    An ipsilateral hip adduction/abduction strength ratio of more than 90%, and hip adduction strength equal to that of the contralateral side have been suggested to clinically represent adequate strength recovery of hip adduction strength in athletes after groin injury. However, to what extent side-......-to-side symmetry in isometric hip adduction and abduction strength can be assumed in soccer players remains uncertain.......An ipsilateral hip adduction/abduction strength ratio of more than 90%, and hip adduction strength equal to that of the contralateral side have been suggested to clinically represent adequate strength recovery of hip adduction strength in athletes after groin injury. However, to what extent side...

  4. The prevalence of predisposing deformity in osteoarthritic hip joints

    DEFF Research Database (Denmark)

    Klit, Jakob; Gosvig, Kasper; Jacobsen, Steffen

    2011-01-01

    relationship in both sexes with the clinical presentation. The study cohort which fulfilled these inclusion criteria consisted of 322 females (149 right hips and 173 left hips) and 162 males (77 right hips and 85 left hips) with osteoarthritis. We found an overall prevalence of predisposing hip deformities...... in females of 62.4% and in males of 78.9%. Minor and major deformities showed the same prevalence. Both sexes had a comparable prevalence of minor and major hip joint deformity, except for pistol grip deformity, which was more prevalent in men. We concluded that 'idiopathic osteoarthritis' is uncommon......, and that even minor predisposing deformities are associated with hip osteoarthritis....

  5. High performance sinter-HIP for hard metals

    International Nuclear Information System (INIS)

    Hongxia Chen; Deming Zhang; Yang Li; Jingping Chen

    2001-01-01

    The horizontal sinter-HIP equipment with great charge capacity and high performance, developed and manufactured by Central Iron and Steel Research Institute(CISRI), is mainly used for sintering and condensation of hard metals. This equipment is characterized by large hot zone, high heating speed, good temperature uniformity and fast cooling system. The equipment can provide uniform hot zone with temperature difference less than 6 o C at 1500-1600 o C and 6-10 MPa by controlling temperature, pressure and circulation of gas precisely. Using large scale horizontal sinter-HIP equipment to produce hard matals have many advantages such as stable quality, high efficiency of production, high rate of finished products and low production cost, so this equipment is a good choice for manufacturer of hard metals. (author)

  6. Comparison between the Harris- and Oxford Hip Score to evaluate outcomes one-year after total hip arthroplasty

    NARCIS (Netherlands)

    Weel, Hanneke; Lindeboom, Robert; Kuipers, Sander E.; Vervest, Ton M. J. S.

    2017-01-01

    Harris Hip Score (HHS) is a surgeon administered measurement for assessing hip function before and after total hip arthroplasties (THA). Patient reported outcome measurements (PROMs) such as the Oxford Hip Score (OHS) are increasingly used. HHS was compaired to the OHS assessing whether the HHS can

  7. Vibroacoustography for the assessment of total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Hermes A.S. Kamimura

    2013-04-01

    Full Text Available OBJECTIVES: This paper proposes imaging with 3-dimensional vibroacoustography for postoperatively assessing the uncovered cup area after total hip arthroplasty as a quantitative criterion to evaluate implant fixation. METHODS: A phantom with a bone-like structure covered by a tissue-mimicking material was used to simulate a total hip arthroplasty case. Vibroacoustography images of the uncovered cup region were generated using a two-element confocal ultrasound transducer and a hydrophone inside a water tank. Topological correction based on the geometry of the implant was performed to generate a 3-dimensional representation of the vibroacoustography image and to accurately evaluate the surface. The 3-dimensional area obtained by the vibroacoustography approach was compared to the area evaluated by a 3-dimensional motion capture system. RESULTS: The vibroacoustography technique provided high-resolution, high-contrast, and speckle-free images with less sensitivity to the beam incidence. Using a 3-dimensional-topology correction of the image, we accurately estimated the uncovered area of the implant with a relative error of 8.1% in comparison with the motion capture system measurements. CONCLUSION: Measurement of the cup coverage after total hip arthroplasty has not been well established; however, the covered surface area of the acetabular component is one of the most important prognostic factors. The preliminary results of this study show that vibroacoustography is a 3-dimensional approach that can be used to postoperatively evaluate total hip arthroplasty. The favorable results also provide an impetus for exploring vibroacoustography in other bone or implant surface imaging applications.

  8. Low revision rate after total hip arthroplasty in patients with pediatric hip diseases

    DEFF Research Database (Denmark)

    Engesæter, Lars B; Engesæter, Ingvild Ø; Fenstad, Anne Marie

    2012-01-01

    Background The results of primary total hip arthroplasties (THAs) after pediatric hip diseases such as developmental dysplasia of the hip (DDH), slipped capital femoral epiphysis (SCFE), or Perthes' disease have been reported to be inferior to the results after primary osteoarthritis of the hip (OA.......9%) were operated due to pediatric hip diseases (3.1% for Denmark, 8.8% for Norway, and 1.9% for Sweden) and 288,435 THAs (77.8%) were operated due to OA. Unadjusted 10-year Kaplan-Meier survival of THAs after pediatric hip diseases (94.7% survival) was inferior to that after OA (96.6% survival......). Consequently, an increased risk of revision for hips with a previous pediatric hip disease was seen (risk ratio (RR) 1.4, 95% CI: 1.3-1.5). However, after adjustment for differences in sex and age of the patients, and in fixation of the prostheses, no difference in survival was found (93.6% after pediatric hip...

  9. [Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].

    Science.gov (United States)

    Medenica, Ivica; Luković, Milan; Radoicić, Dragan

    2010-02-01

    The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score--7.1). We performed total rearthroplasty by a custom-made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score--87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specificaly for a patient) and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  10. Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis

    Directory of Open Access Journals (Sweden)

    Medenica Ivica

    2010-01-01

    Full Text Available Background. The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. Case report. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score - 7.1. We performed total rearthroplasty by a custom- made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score - 87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Conclusion. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specifically for a patient and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  11. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

    Science.gov (United States)

    Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki

    2018-06-01

    We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. MR imaging of the hip

    International Nuclear Information System (INIS)

    Kramer, J.

    2006-01-01

    Full text: MRI has been shown to gain increasing importance in recent years in the evaluation of disorders of the hip and pelvis. Nowadays, conventional or fast spin echo (T1, Turbo (Fast) T2 (or PD)) MR imaging sequences are used most commonly to examine the hip and pelvis. Three dimensional (3D) gradient echo (GE) imaging allows acquisition of very thin (1 mm) sections. MR imaging with fat suppression technique (STIR, TIRM, FAT SAT T2) represent an effective screening technique for the assessment of fluid, hemorrhage, pus, or tumor in the marrow, joint or soft tissues. These techniques increase the sensitivity for the detection of a variety of pathologic processes. Fat suppression MR imaging, when combined with intravenous (or intraarticular) administration of a gadolinium compound, also is effective and often is employed when evaluating neoplastic or infectious diseases (intravenous injection), abnormalities of articular cartilage or labrum, or possible intraarticular osteocartilaginous bodies (intraarticular injection). A lesion of the acetabular labrum based is one cause of chronic hip pain in patients with developmental dysplasia of the hips, as well as in patients with a history of hip trauma or femoroacetabular impingement. MR imaging and, in particular, MR arthrography, however, have been shown to be highly accurate in the detection of subtle intraarticular abnormalities such as labral lesion. Conventional MR imaging has shown poor accuracy in detecting labral lesions, due to its inability to depict small tears and the difficulty in determining if intralabral signal abnormalities extend to the surface of the labrum. MR arthrography, however has been shown to overcome these difficulties and to have excellent accuracy in detecting labral pathology. As labral abnormalities are believed to be a precursor of osteoarthritis, orthopedic surgeons believe that surgical intervention will be influenced substantially by the type, extension and location of labral

  13. A new algorithm for hip fracture surgery

    DEFF Research Database (Denmark)

    Palm, Henrik; Krasheninnikoff, Michael; Holck, Kim

    2012-01-01

    Background and purpose Treatment of hip fracture patients is controversial. We implemented a new operative and supervision algorithm (the Hvidovre algorithm) for surgical treatment of all hip fractures, primarily based on own previously published results. Methods 2,000 consecutive patients over 50...... years of age who were admitted and operated on because of a hip fracture were prospectively included. 1,000 of these patients were included after implementation of the algorithm. Demographic parameters, hospital treatment, and reoperations within the first postoperative year were assessed from patient...... by reoperations was reduced from 24% of total hospitalization before the algorithm was introduced to 18% after it was introduced. Interpretation It is possible to implement an algorithm for treatment of all hip fracture patients in a large teaching hospital. In our case, the Hvidovre algorithm both raised...

  14. Traction-related problems after hip arthroscopy

    DEFF Research Database (Denmark)

    Frandsen, Lone; Lund, Bent; Grønbech Nielsen, Torsten

    2017-01-01

    . The questionnaire included questions on patients' perceptions of traction-related problems in the groin area, at the knee and ankle and how patients had coped with these problems. A total of 100 consecutive patients undergoing hip arthroscopy filled out the questionnaire. Primary findings of this study were that 74......% of patients reported some sort of traction-related problems after hip arthroscopy. About 32% of the patients had problems in the groin area and 49% of the patients complained of symptoms in the knee joint. A total of 37% of the patients had experienced problems from the traction boot in the ankle area....... The complications were found to be temporary and disappeared after 2-4 weeks. Five patients still had complaints after 3 months. All five patients had a pre-existing knee injury prior to undergoing hip arthroscopy. Traction-related problems after hip arthroscopy are a challenge and our study showed that 74...

  15. Hip-hop, Onegin - pop! / Tatjana Aleksandrova

    Index Scriptorium Estoniae

    Aleksandrova, Tatjana, 1945-

    2004-01-01

    Erateatrikooli KS, mida juhib Svetlana Krassman, lavastus A. Pushkini poeemi "Jevgeni Onegin" motiividel. Noortelavastuse muusikalises seades kasutatakse klassikalise muusika aranzheeringuid ja räppi, kostüümidraamat koos hip-hop rõivastiiliga

  16. Scintigraphic presentation of hip joint synovial chondromatosis

    Energy Technology Data Exchange (ETDEWEB)

    Zwas, S T; Friedman, B; Nerubay, J

    1988-09-01

    A case of hip joint synovial chondromatosis with an unusual scintigraphic pattern is described. This pattern was suggestive of a hip joint destructive reactive articular process or late manifestations of avascular necrosis of the femoral head. Concurrent radiographs were normal, as were laboratory investigations. Follow-up radiographs six months later showed radiolucencies and erosive bone changes in the diseased joint. Surgical and histopathological findings revealed well developed hip synovial chondromatosis (HSC) with thickened synovium and large, loose, cartilaginous bodies occupying and widening the tightened joint space, with destructive secondary juxta articular pressure and bone erosions. This and other scintigraphic patterns in HSC, and the differential diagnosis of the findings in patients with painful hip presentations are discussed.

  17. Relationship between selected measures of strength and hip and knee excursion during unilateral and bilateral landings in women.

    Science.gov (United States)

    McCurdy, Kevin; Walker, John; Armstrong, Rusty; Langford, George

    2014-09-01

    The purpose of this study was to compare the relationship between several measures of single-joint, isometric, eccentric, and squat strength and unilateral and bilateral landing mechanics at the hip and knee in women. Twenty six healthy female subjects with previous athletic experience (height, 165.1 ± 7.01 cm; mass, 60.91 ± 7.14 kg; age, 20.9 ± 1.62 years) participated in this study. Hip and knee mechanics were measured using the MotionMonitor capture system (Innovative Sports Training, Inc.) with 3-dimensional electromagnetic sensors during bilateral (60 cm) and unilateral drop jumps (30 cm). On a separate day, isometric hip extension, external rotation, and abduction strength (lbs) were measured using a handheld dynamometer (Hoggan Health Industries, Inc.). Eccentric and isometric knee strength were measured on the Biodex IV Isokinetic Dynamometer (Biodex Medical Systems, Inc.). Free weight was used to measure the bilateral squat and a modified single-leg squat. The strongest correlations were found between squat strength and knee valgus (-0.77 ≤ r ≤ -0.83) and hip adduction (-0.5 ≤ r ≤ -0.65). After controlling for squat strength, hip external rotation strength and unilateral knee valgus (-0.41), hip abduction strength and bilateral knee valgus (-0.43), and knee flexion strength and bilateral hip adduction (-0.57) remained significant. Eccentric knee flexion strength and unilateral knee internal rotation was the only significant correlation for eccentric strength (-0.40). Squat strength seems to be the best predictor of knee valgus and was consistently related to hip adduction. Isometric and eccentric measures demonstrated few significant correlations with hip and knee excursion while demonstrating a low-to-moderate relationship. Hip and knee flexion and rotation do not seem to be related to strength. Squat strength should receive consideration during risk assessment for noncontact knee injury.

  18. Epidemiology of hip fracture: Worldwide geographic variation

    Directory of Open Access Journals (Sweden)

    Dinesh K Dhanwal

    2011-01-01

    Full Text Available Osteoporosis is a major health problem, especially in elderly populations, and is associated with fragility fractures at the hip, spine, and wrist. Hip fracture contributes to both morbidity and mortality in the elderly. The demographics of world populations are set to change, with more elderly living in developing countries, and it has been estimated that by 2050 half of hip fractures will occur in Asia. This review conducted using the PubMed database describes the incidence of hip fracture in different regions of the world and discusses the possible causes of this wide geographic variation. The analysis of data from different studies show a wide geographic variation across the world, with higher hip fracture incidence reported from industrialized countries as compared to developing countries. The highest hip fracture rates are seen in North Europe and the US and lowest in Latin America and Africa. Asian countries such as Kuwait, Iran, China, and Hong Kong show intermediate hip fracture rates. There is also a north-south gradient seen in European studies, and more fractures are seen in the north of the US than in the south. The factors responsible of this variation are population demographics (with more elderly living in countries with higher incidence rates and the influence of ethnicity, latitude, and environmental factors. The understanding of this changing geographic variation will help policy makers to develop strategies to reduce the burden of hip fractures in developing countries such as India, which will face the brunt of this problem over the coming decades.

  19. CTXA hip--an extension of classical DXA measurements using quantitative CT.

    Science.gov (United States)

    Cann, Christopher E; Adams, Judith E; Brown, J Keenan; Brett, Alan D

    2014-01-01

    Bone mineral density (BMD) estimates for the proximal femur using Dual Energy X-ray Absorptiometry (DXA) are currently considered the standard for making a diagnosis of osteoporosis in an individual patient using BMD alone. We have compared BMD results from a commercial Quantitative CT (QCT) BMD analysis system, "CTXA Hip", which provides clinical data for the proximal femur, to results from DXA. We have also used CTXA Hip to determine cortical and trabecular contributions to total BMD. Sixty-nine patients were scanned using 3D QCT and DXA. CTXA Hip BMD measurements for Total Hip and Femoral Neck were compared to DXA results. Twenty-two women were scanned at 0, 1, 2 years and CTXA Hip and DXA results analyzed for long-term reproducibility. Long-term reproducibility calculated as root-mean-square averages of SDs in vivo was 0.012 g/cm2 (CV = 1.8%) for CTXA Total Hip and 0.011 g/cm2 (CV = 2.0%) for CTXA Femoral Neck compared to 0.014 g/cm2 (CV = 2.0%) and 0.016 g/cm2 (CV = 2.7%), respectively, for DXA. The correlation of Total Hip BMD CTXA vs. DXA was R = 0.97 and for Femoral Neck was R = 0.95 (SEE 0.044 g/cm2 in both cases). Cortical bone comprised 62±5% (mean ± SD) of total hipbone mass in osteoporotic women. CTXA Hip provides substantially the same clinical information as conventional DXA and in addition provides estimates of BMD in separate cortical and trabecular bone compartments, which may be useful in evaluation of bone strength.

  20. CTXA hip--an extension of classical DXA measurements using quantitative CT.

    Directory of Open Access Journals (Sweden)

    Christopher E Cann

    Full Text Available Bone mineral density (BMD estimates for the proximal femur using Dual Energy X-ray Absorptiometry (DXA are currently considered the standard for making a diagnosis of osteoporosis in an individual patient using BMD alone. We have compared BMD results from a commercial Quantitative CT (QCT BMD analysis system, "CTXA Hip", which provides clinical data for the proximal femur, to results from DXA. We have also used CTXA Hip to determine cortical and trabecular contributions to total BMD. Sixty-nine patients were scanned using 3D QCT and DXA. CTXA Hip BMD measurements for Total Hip and Femoral Neck were compared to DXA results. Twenty-two women were scanned at 0, 1, 2 years and CTXA Hip and DXA results analyzed for long-term reproducibility. Long-term reproducibility calculated as root-mean-square averages of SDs in vivo was 0.012 g/cm2 (CV = 1.8% for CTXA Total Hip and 0.011 g/cm2 (CV = 2.0% for CTXA Femoral Neck compared to 0.014 g/cm2 (CV = 2.0% and 0.016 g/cm2 (CV = 2.7%, respectively, for DXA. The correlation of Total Hip BMD CTXA vs. DXA was R = 0.97 and for Femoral Neck was R = 0.95 (SEE 0.044 g/cm2 in both cases. Cortical bone comprised 62±5% (mean ± SD of total hipbone mass in osteoporotic women. CTXA Hip provides substantially the same clinical information as conventional DXA and in addition provides estimates of BMD in separate cortical and trabecular bone compartments, which may be useful in evaluation of bone strength.

  1. Evaluation of surgical outcome in advanced age patients with developmental hip dysplasia.

    Science.gov (United States)

    Çiçekli, Özgür; Doğan, Metin

    2018-04-01

    This study aimed at determining the efficacy of the surgical treatment conducted on children with delayed presentation developmental dysplasia of the hip (DDH). The objective was to provide a good comparison of functional and radiographic outcomes and to determine various surgical treatment options. In this study, we evaluated the results of 38 hips of 27 patients aged 4 years onset which had been operated due to DDH. Radiographic outcomes were evaluated by using acetabular index, CE angle, Tonnis and the Severin classification system. Clinical evaluation was made by using IOWA hip scores. Degenerative changes were evaluated according to Boyer and avascular necrosis according to Kalamchi-MacEwen criteria. The mean age of the patients at the operation time was 10 years 3 months (range: 4 years 3 months-30 years). While the mean acetabular index was 37.97 preoperatively, in the last follow-up it was 19.92. Thirty-six hips (94%) had an excellent and good outcomes, and two hips (%6) had a fair outcome with respect to the Severin criteria. The mean hip score with respect to IOWA was 93.736 (range: 75-98) and the rate of excellent and good outcomes was 98%. For the treatment of patients with DDH of late onset, a one-staged operative procedure is recommended. This method is applied successfully and enables us to achieve good clinical and radiographic results. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  2. COXA-VERTEBRAL SYNDROME AND ITS SIGNIFICANCE IN HIP ARTHROPLASTY (REVIEW

    Directory of Open Access Journals (Sweden)

    A. O. Denisov

    2012-01-01

    Full Text Available Lumbosacral spine and hip joints is a complex physiological functions of the co-operation of a large number of anatomical structures. Lesions of the links in the system can mutually afflict each other. Combined pathology of the hip and lumbosacral spine is called hip-spine syndrome, or coxa-vertebral syndrome. Symptoms of the joint and spine are very similar and only a careful examination and clinical examination may find the differences. As the disease progresses the hip increases the restriction of movement, there is a contracture of the limbs in a vicious position, which leads to an increase in tilt of the pelvis, increased lumbar lordosis and to functional shortening of limbs on the affected side. This gives rise to functional impairment, and then strain the joints of his spine and disease - osteochondrosis and scoliosis. After the successful operation of total hip replacement is often progressive clinical lesions of vertebral segment, which is manifested pain and is often offset by the results of arthroplasty as the restoration of movement in the hip joint, and the change in length limb after arthroplasty leads to rupture formed a functional stereotype change in the mobility of the lumbar spine, pelvis regression bias that causes the dynamic compression spinal nerve root. Depending on the duration of the existence, severity and nature of changes in the pelvic girdle is suitable correction of equipment replacement surgery, including, for example, in some cases, deliberate shortening or lengthening the preservation of the lower extremity, offset change, etc.

  3. Functional recovery of older people with hip fracture: does malnutrition make a difference?

    Science.gov (United States)

    Li, Hsiao-Juan; Cheng, Huey-Shinn; Liang, Jersey; Wu, Chi-Chuan; Shyu, Yea-Ing Lotus

    2013-08-01

    To report a study of the effects of protein-energy malnutrition on the functional recovery of older people with hip fracture who participated in an interdisciplinary intervention. It is not clear whether protein-energy malnutrition is associated with worse functional outcomes or it affects the interdisciplinary intervention program on the functional recovery of older people with hip fracture. A randomized experimental design. Data were collected between 2002-2006 from older people with hip fracture (N = 162) in Taiwan. The generalized estimating equations approach was used to evaluate the effect of malnutrition on the functional recovery of older people with hip fracture. The majority of older patients with hip fracture were malnourished (48/80, 60% in the experimental group vs. 55/82, 67% in the control group) prior to hospital discharge. The results of the generalized estimating equations analysis demonstrated that subjects suffering from protein-energy malnutrition prior to hospital discharge appeared to have significantly worse performance trajectories for their activities of daily living, instrumental activities of daily living, and recovery of walking ability compared with those without protein-energy malnutrition. In addition, it was found that the intervention is more effective on the performance of activities of daily living and recovery of walking ability in malnourished patients than in non-malnourished patients. Healthcare providers should develop a nutritional assessment/management system in their interdisciplinary intervention program to improve the functional recovery of older people with hip fracture. © 2012 Blackwell Publishing Ltd.

  4. USING CUSTOM TRIFLANGE IMPLANT IN REVISION HIP ARTHROPLASTY IN PATIENT WITH PELVIC DISCONTINUITY (CASE REPORT

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2016-01-01

    Full Text Available Revision hip arthroplasty rate is growing, and pelvic discontinuity rate ranges from 1% to 5% of acetabular component revision reasons. According to AAOS acetabular defects classification, pelvic discontinuity is fourth type defect in which cranial part of hip bone is separated from caudal part at acetabular level. Usually it occurs from bone loss secondary to osteolysis, infection, fracture or aseptic loosening. There are a lot of techniques for pelvis discontinuity treatment. Published results of bulk allografts and antiprotrusion cages have generally been poor. More preferable methods with acceptable rate of good results are cup-cage systems and custom triflange acetabular components(CTAC. CTACs are designed based on preoperative CT scans to build a custom titanium 3D-printed implant to address the patient's specific bone defect and provide secure fixation in the ilium, pubis, and ischium. We faced pelvic discontinuity, in which extensive iliac bone loss was added to caudal hip bone part medial displacement and pelvic ring deformity, in patient with multiple hip surgeries. Preoperative investigation called into question the possibility of using off-the-shelf hip implants, which could restore the biomechanics of the hip and provide reliable primary fixation at the same time. We present case report of the patient with pelvic discontinuity and massive bone loss treatment using a custom triflange component.

  5. No evidence hip joint angle modulates intrinsically produced stretch reflex in human hopping.

    Science.gov (United States)

    Gibson, W; Campbell, A; Allison, G

    2013-09-01

    Motor output in activities such as walking and hopping is suggested to be mediated neurally by purported stretch reflex augmentation of muscle output. Reflex EMG activity during these tasks has been frequently investigated in the soleus muscle; with alterations in reflex amplitude being associated with changes in hip joint angle/phase of the gait cycle. Previous work has focussed on reflex activity induced by an artificial perturbation or by induction of H-reflexes. As such, it is currently unknown if stretch reflex activity induced intrinsically (as part of the task) is modulated by changes in hip joint angle. This study investigated whether hip joint angle modulated reflex EMG 'burst' activity during a hopping task performed on a custom-built partially reclined sleigh. Ten subjects participated; EMG and kinematic data (VICON motor capture system) was collected for each hop cycle. Participants completed 5 sets of 30s of self-paced hopping in (1) hip neutral and (2) hip 60° flexion conditions. There was no difference in EMG 'burst' activity or in sagittal plane kinematics (knee/ankle) in the hopping task between the two conditions. The results indicate that during a functional task such as hopping, changes in hip angle do not alter the stretch reflex-like activity associated with landing. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. The Timing of Hip Arthroscopy After Intra-articular Hip Injection Affects Postoperative Infection Risk.

    Science.gov (United States)

    Wang, Dean; Camp, Christopher L; Ranawat, Anil S; Coleman, Struan H; Kelly, Bryan T; Werner, Brian C

    2017-11-01

    To evaluate the association of preoperative intra-articular hip injection with surgical site infection after hip arthroscopy. A large administrative database was used to identify all patients undergoing hip arthroscopy from 2007 to 2015 within a single private insurer and from 2005 to 2012 within Medicare in the United States. Those that received an ipsilateral preoperative intra-articular hip injection were identified. The patients were then divided into the following groups based on the interval between preoperative injection and ipsilateral hip arthroscopy: (1) 12 months) of preoperative hip injection. Patients developing a surgical site infection within 6 months following hip arthroscopy were identified using International Classification of Diseases, Ninth Revision, and Current Procedural Terminology codes associated with infection. Groups were compared using a multivariate logistic regression analysis to control for age, gender, body mass index, smoking status, alcohol usage, and multiple medical comorbidities including diabetes mellitus, hemodialysis use, inflammatory arthritis, and peripheral vascular disease. In total, 19% of privately insured and 6% of Medicare patients received a hip injection within 12 months of hip arthroscopy. The overall infection rate in privately insured and Medicare patients was 1.19% and 1.10%, respectively. Preoperative hip injection within 3 months of surgery was associated with a significantly higher risk of postoperative infection versus controls (2.16%, odds ratio [OR] 6.1, P arthroscopy increased when preoperative intra-articular hip injections were given within 3 months of surgery. Level III, retrospective comparative study. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. Gait analysis in hip viscosupplementation for osteoarthritis: a case report

    Directory of Open Access Journals (Sweden)

    L. Di Lorenzo

    2013-10-01

    Full Text Available Hip is a site very commonly affected by osteoarthritis and the intra-articular administration of hyaluronic acid in the management of osteoarthritic pain is increasingly used. However, the debate about its usefulness is still ongoing, as not all results of clinical trials confirm its effectiveness. In order to achieve the best outcome, clinical assessment and treatment choices should be based on subjective outcome, pathological and mechanical findings that should be integrated with qualitative analysis of human movement. After viscosupplementation, clinical trials often evaluate as endpoint subjective outcomes (i.e. pain visual analogic scale and static imaging such as radiographs and magnetic resonance imaging. In our clinical practice we use gait analysis as part of rehabilitation protocol to measure performance, enhancement and changes of several biomechanical factors. Taking advantage of available resources (BTS Bioengineering gait analysis Elite System we studied a patient’s gait after ultrasound guided hip injections for viscosupplementation. He showed an early clinical and biomechanical improvement during walking after a single intra articular injection of hyaluronic acid. Gait analysis parameters obtained suggest that the pre-treatment slower speed may be caused by antalgic walking patterns, the need for pain control and muscle weakness. After hip viscosupplementation, the joint displayed different temporal, kinetic and kinematic parameters associated with improved pain patterns.

  8. Postoperative radiotherapy prophylaxis of periarticular ossification after total hip replacement

    International Nuclear Information System (INIS)

    Sauer, R.; Seegenschmiedt, M.H.; Andreas, P.; Goldmann, A.; Beck, H.

    1992-01-01

    Since June 1988, we have treated 77 patients or 80 hips respectively with prophylactic irradiation. Individual risk factors included severe coxarthrosis grade IV, ipsi- or contralateral heterotopic ossification and severe hip trauma. As of July 1991 60 patients with a minimum follow-up of six months could be analyzed using clinical and radiological scoring systems. The patients had been prospectively randomized in two different treatment arms: 32 patients were treated with low dose (LD), five times 2 Gy daily fractions to a total dose of 10 Gy, whereas 28 patients were treated with high dose (HD), ten times 2 Gy (eight patients) or five times 3.5 Gy (20 patients). Operative procedures and individual risk factors were equally distributed in both groups. 23 patients (38% received indometacin three times 25 mg for six weeks, 19 patients (32%) diphosphonate EHDP 20 mg/kg body weight and 18 patients (30%) had no additional medication. 56/60 (93%) patients developed no significant heterotopic ossification and/or remained without impairment of their postoperative radiological and clinical hip status according to the applied Brooker and Harris Scores. Only 4/60 (7%) patients demonstrated treatment failures developing postoperative worsening one grade of Brooker score in two patients and two and three grades of Brooker score in the two others. Only 1/49 patients experienced a treatment failure, when radiotherapy had been initiated before and at postoperative day 4 compared to 3/11 patients initiated after postoperative day 4 (p [de

  9. The characteristics of the mechanoreceptors of the hip with arthrosis

    Science.gov (United States)

    2011-01-01

    Mechanoreceptors have been extensively studied in different joints and distinct signals that convey proprioceptive information to the cortex. Several clinical reports have established a link between the number of mechanoreceptors and a deficient proprioceptive system; however, little or no literature suggest concentration of mechanoreceptors might be affected by hip arthrosis. The purpose of this study is first to determine the existence of mechanoreceptors and free nerve endings in the hip joint and to distinguish between their conditions: those with arthrosis and without arthrosis. Samples of 45 male hips were analyzed: 30 taken from patients with arthrosis that were submitted to total arthroplasty and 15 taken from male cadavers without arthrosis. The patients' ages ranged from 38 to75 years (average 56.5) and the cadavers' ages ranged from 21 to 50 years (average 35.5). The capsule, labrum, and femoral head ligament tissues were obtained during the arthroplasty procedure from 30 patients with arthrosis and from 15 male cadavers. The tissue was cut into fragments of around 3 mm. Each fragment was then immediately stained with gold chloride 1% solution and divided into sections of 6 μm thickness. The Mann-Whitney test was used for two groups and the ANOVA, Friedman and Kruskal-Wallis tests for more than two groups. Results show the mechanoreceptors (Pacini, Ruffini and Golgi corpuscles) and free nerve endings are present in the capsule, femoral head ligament, and labrum of the hip joint. When all the densities of the nerve endings were examined with regard to those with arthrosis and those without arthrosis, the mechanoreceptors of cadavers without arthrosis were found to be more pronounced and an increase in free nerve endings could be observed (p = 0.0082). Further studies, especially electrophysiological studies, need to be carried out to clarify the functions of the mechanoreceptors in the joints. PMID:22087603

  10. Pressure sores and hip fractures.

    Science.gov (United States)

    Haleem, S; Heinert, G; Parker, M J

    2008-02-01

    Development of pressure sores during hospital admission causes morbidity and distress to the patient, increases strain on nursing resources, delaying discharge and possibly increasing mortality. A hip fracture in elderly patients is a known high-risk factor for development of pressure sores. We aimed to determine the current incidence of pressure sores and identify those factors which were associated with an increased risk of pressure sores. We retrospectively analysed prospectively collected data of 4654 consecutive patients admitted to a single unit. One hundred and seventy-eight (3.8%) of our patients developed pressure sores. Patient factors that increased the risk of pressure sores were increased age, diabetes mellitus, a lower mental test score, a lower mobility score, a higher ASA score, lower admission haemoglobin and an intra-operative drop in blood pressure. The risk was higher in patients with an extracapsular neck of femur fracture and patients with an increased time interval between admission to hospital and surgery. Our studies indicate that while co-morbidities constitute a substantial risk in an elderly population, the increase in incidence of pressure sores can be reduced by minimising delays to surgery.

  11. Hip arthroplasty today and tomorrow.

    Science.gov (United States)

    Amstutz, H C

    1987-12-01

    Acrylic-fixed total hip and surface replacement arthroplasty have been very effective in affording immediate relief of pain and providing improved function. Complications have been reduced by improvements in design, materials, and especially technique. They are now very low in the elderly, and the stem type acrylic-fixed design remains the procedure of choice. The failure rates in youthful patients and those with bone-stock deficiencies have been high in both THR and surface types, although the latter had the advantage of preserving femoral stock. On the femoral side, the new "macro" femoral designs from Europe and "micro" femoral porous designs have shown promise, but thigh pain, incomplete and difficult to predict bone ingrowth patterns, coupled with removal problems have influenced design and technique changes. Both press-fit stem types and porous surface replacements have produced promising initial results with less potential downside risks. On the acetabular side, both the cementless hemispherical with screw-type adjuvant fixation, or the chamfered cylinder designs, used primarily with the UCLA porous surface replacements, but also with stem-type devices, appear to achieve best short-term results, while the entire variety of screw rings are disappointing. The future will bring further refinements in technique and specific indications for certain types of replacement stem in specific types of bone stock deficiencies. The all ceramic-ceramic and ceramic-polyethylene bearings show promise of reducing wear and, hence, should improve longevity of implant fixation.

  12. HIP HOP for HIV Awareness: Using Hip Hop Culture to Promote Community-Level HIV Prevention

    Science.gov (United States)

    Hill, Mandy J.; Hallmark, Camden J.; McNeese, Marlene; Blue, Nike; Ross, Michael W.

    2014-01-01

    The goal of this paper was to determine the effectiveness of the HIP HOP for HIV Awareness intervention, an innovative model utilising an exchange of an HIV test for a hip hop concert ticket, in a metropolitan city among African American youth and young adults. A subset of intervention participants participated in standardised testing, sex…

  13. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    Science.gov (United States)

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  14. Don't forget the hip! Hip arthritis masquerading as knee pain

    Directory of Open Access Journals (Sweden)

    Florian F. Dibra, MD

    2018-03-01

    Full Text Available Background: Hip osteoarthritis typically manifests with groin or thigh pain. Other atypical pain patterns, including knee pain, have been described. Except for 2 case reports, there is no literature on this subject. Methods: From our institutional database, between 2011 and 2016, we identified 21 patients who were referred for treatment of knee pain but ultimately diagnosed with hip pathology as the cause of their pain. This group was evaluated for duration of symptoms prior to diagnosis, previous interventions, presence of walking aids, and symptom resolution after treatment of the hip pathology. Results: Fifteen of the 21 patients were referred from musculoskeletal providers (12 from orthopaedic surgeons. Prior to diagnosis of the hip etiology, 16 patients were reduced to major assistive devices including wheelchairs. Twelve of 21 patients had undergone surgical knee interventions, including total knee arthroplasty, with minimal to no relief of their pain. Seventeen of 21 referred patients underwent total hip arthroplasty at our institution. Fourteen patients had complete resolution of knee pain after total hip arthroplasty. Conclusions: Although knee pain referred from hip disease may be considered a basic and common knowledge, it continues to be an overlooked phenomenon. Most of the cases were misdiagnosed by musculoskeletal providers including orthopaedic surgeons and this highlights the need for continued education and awareness of this clinical scenario. Keywords: Hip pain, Knee pain, Referred pain, Delay in diagnosis, Unnecessary surgery

  15. Hip and ankle range of motion and hip muscle strength in young female ballet dancersand controls

    Science.gov (United States)

    Bennell, K.; Khan, K. M.; Matthews, B.; De Gruyter, M.; Cook, E.; Holzer, K.; Wark, J. D.

    1999-01-01

    OBJECTIVES: To compare the hip and ankle range of motion and hip muscle strength in 8-11 year old novice female ballet dancers and controls. METHODS: Subjects were 77 dancers and 49 controls (mean (SD) age 9.6 (0.8) and 9.6 (0.7) years respectively). Supine right active hip external rotation (ER) and internal rotation (IR) were measured using an inclinometer. A turnout protractor was used to assess standing active turnout range. The measure of ER achieved from below the hip during turnout (non-hip ER) was calculated by subtracting hip ER range from turnout range, and hip ER:IR was derived by dividing ER range by IR range. Range of right weight bearing ankle dorsiflexion was measured in a standing lunge using two methods: the distance from the foot to the wall (in centimetres) and the angle of the shank to the vertical via an inclinometer (in degrees). Right calf muscle range was measured in weight bearing using an inclinometer. A manual muscle tester was used to assess right isometric hip flexor, internal rotator, external rotator, abductor, and adductor strength. RESULTS: Dancers had less ER (pballetic training. 


 PMID:10522638

  16. Reliability and Validity of the Hip Stability Isometric Test (HipSIT): A New Method to Assess Hip Posterolateral Muscle Strength.

    Science.gov (United States)

    Almeida, Gabriel Peixoto Leão; das Neves Rodrigues, Helena Larissa; de Freitas, Bruno Wesley; de Paula Lima, Pedro Olavo

    2017-12-01

    Study Design Cross-sectional study. Background The Hip Stability Isometric Test (HipSIT) evaluates the strength of the hip posterolateral stabilizers in a position that favors greater activation of the gluteus maximus and gluteus medius and lower activation of the tensor fascia lata. Objectives To check the validity and reliability of the HipSIT and to evaluate the HipSIT in women with patellofemoral pain (PFP). Methods The HipSIT was evaluated with a handheld dynamometer. During testing, the participants were sidelying, with their legs positioned at 45° of hip flexion and 90° of knee flexion. Participants were instructed to raise the knee of the upper leg while keeping the upper and lower heels in contact. To establish reliability and validity, 49 women were tested with the HipSIT by 2 different evaluators on day 1, and then again 7 days later. The strength of the hip extensors, abductors, and external rotators was also evaluated. Twenty women with unilateral PFP were also evaluated. Results The HipSIT has excellent intrarater and interrater reliability. The standard error of measurement was 0.01 kgf/kg, and the minimal detectable change was 0.036 kgf/kg. The HipSIT showed good validity in isolated hip abduction, external rotation, and extension (Pstrength deficits in women with PFP. J Orthop Sports Phys Ther 2017;47(12):906-913. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7274.

  17. Process optimized minimally invasive total hip replacement

    Directory of Open Access Journals (Sweden)

    Philipp Gebel

    2012-02-01

    Full Text Available The purpose of this study was to analyse a new concept of using the the minimally invasive direct anterior approach (DAA in total hip replacement (THR in combination with the leg positioner (Rotex- Table and a modified retractor system (Condor. We evaluated retrospectively the first 100 primary THR operated with the new concept between 2009 and 2010, regarding operation data, radiological and clinical outcome (HOOS. All surgeries were perfomed in a standardized operation technique including navigation. The average age of the patients was 68 years (37 to 92 years, with a mean BMI of 26.5 (17 to 43. The mean time of surgery was 80 min. (55 to 130 min. The blood loss showed an average of 511.5 mL (200 to 1000 mL. No intra-operative complications occurred. The postoperative complication rate was 6%. The HOOS increased from 43 points pre-operatively to 90 (max 100 points 3 months after surgery. The radiological analysis showed an average cup inclination of 43° and a leg length discrepancy in a range of +/- 5 mm in 99%. The presented technique led to excellent clinic results, showed low complication rates and allowed correct implant positions although manpower was saved.

  18. Hip malformation is a very common finding in young patients scheduled for total hip arthroplasty

    DEFF Research Database (Denmark)

    Karimi, Dennis; Kallemose, Thomas; Troelsen, Anders

    2018-01-01

    and prevalences of hip malformations were; CAM-deformity 50.9 and 25.5%, coxa profunda 33 and 27.4%, acetabular retroversion 33 and 29.2%, and acetabular dysplasia 10.4 and 3.8%. All patients showed minimum of one malformation. Prevalences of Tönnis grade 0-1 were 22.6% and 2-3 were 77.4%. CONCLUSION: All......INTRODUCTION: In Denmark, 20% of all registered total hip arthroplasties (THA) from 1995 to 2014 has been patients younger than 60 years with primary idiopathic osteoarthritis (OA). It is speculated that hip malformations may be a major contributor to early OA development. It has been shown...... that hip malformation may compromise implant position and, therefore, identifying and knowing the incidence of malformations is important. Our aim was to assess the prevalence and type of hip malformations in a cohort of younger patients undergoing THA. MATERIALS AND METHODS: In this prospective two center...

  19. Automatic assessment of volume asymmetries applied to hip abductor muscles in patients with hip arthroplasty

    Science.gov (United States)

    Klemt, Christian; Modat, Marc; Pichat, Jonas; Cardoso, M. J.; Henckel, Joahnn; Hart, Alister; Ourselin, Sebastien

    2015-03-01

    Metal-on-metal (MoM) hip arthroplasties have been utilised over the last 15 years to restore hip function for 1.5 million patients worldwide. Althoug widely used, this hip arthroplasty releases metal wear debris which lead to muscle atrophy. The degree of muscle wastage differs across patients ranging from mild to severe. The longterm outcomes for patients with MoM hip arthroplasty are reduced for increasing degrees of muscle atrophy, highlighting the need to automatically segment pathological muscles. The automated segmentation of pathological soft tissues is challenging as these lack distinct boundaries and morphologically differ across subjects. As a result, there is no method reported in the literature which has been successfully applied to automatically segment pathological muscles. We propose the first automated framework to delineate severely atrophied muscles by applying a novel automated segmentation propagation framework to patients with MoM hip arthroplasty. The proposed algorithm was used to automatically quantify muscle wastage in these patients.

  20. Hip fracture in hospitalized medical patients.

    Science.gov (United States)

    Zapatero, Antonio; Barba, Raquel; Canora, Jesús; Losa, Juan E; Plaza, Susana; San Roman, Jesús; Marco, Javier

    2013-01-08

    The aim of the present study is to analyze the incidence of hip fracture as a complication of admissions to internal medicine units in Spain. We analyzed the clinical data of 2,134,363 adults who had been admitted to internal medicine wards. The main outcome was a diagnosis of hip fracture during hospitalization.Outcome measures included rates of in-hospital fractures, length of stay and cost. A total of 1127 (0.057%) admittances were coded with an in-hospital hip fracture. In hospital mortality rate was 27.9% vs 9.4%; p patients with a hip fracture (20.7 days vs 9.8 days; p hip-fracture patients (6927€ per hospitalization vs 3730€ in non fracture patients). Risk factors related to fracture were: increasing age by 10 years increments (OR 2.32 95% CI 2.11-2.56), female gender (OR 1.22 95% CI 1.08-1.37), admission from nursing home (OR 1.65 95% CI 1.27-2.12), dementia (1.55 OR 95% CI1.30-1.84), malnutrition (OR 2.50 95% CI 1.88-3.32), delirium (OR 1.57 95% CI 1.16-2.14), and anemia (OR 1.30 95%CI 1.12-1.49). In-hospital hip fracture notably increased mortality during hospitalization, doubling the mean length of stay and mean cost of admission. These are reasons enough to stress the importance of designing and applying multidisciplinary plans focused on reducing the incidence of hip fractures in hospitalized patients.

  1. [Efficacy analysis on hip replacement for hip-joint diseases with Parkinson disease].

    Science.gov (United States)

    Sun, Qi-Cai; Ru, Xuan-Liang; Xia, Yan-Fei; Liu, Xiao-Li; Song, Bai-Shan; Qiao, Song; Yan, Shi-Gui; Wang, Xiang-Hua

    2017-12-25

    To explore clinical efficacy of hip replacement for hip-joint diseases with Parkinson disease. From December 2011 to December 2016, 18 patients with hip-joint diseases with Parkinson disease treated by hip replacement, including 8 males and 10 females aged from 59 to 87 years old with an average of 71 years old. Among them, 3 cases were developmental dysplasia of hip, 3 cases were femoral head necrosis and 12 cases were femoral neck fracture. All patients manifested with obvious pain and limitation of stepping ability. Postoperative complications were observed and Harris score were used to compare hip joint function after operation. The incision were healed well, and pain were alleviated or disappeared, and hip joint function were improved. Eighteen patients were followed up from 1 to 3 years with an average of 2.3 years. At the latest follow up, 14 cases recovered freedom-walk, 2 cases could walk with walking stick, 1 case could walk with walking aid and 1 case was died. Among 18 patients, 2 cases were occurred dislocation, and 1 case were died for cardiac disease at 3 months after operation. Four patients were occurred slight pain. There were significant differences in Harris scores among preoperative (41.7±1.4), 6 months after operation(80.1±5.4) and the final follow-up (83.4±2.1), and 10 cases got excellent result, 4 good, 1 fair and 2 poor. Application of hip replacement for hip-joint diseases with Parkinson disease is a safe and effective clinical therapy, and has advantages of less complications and rapid recovery of hip joint function.

  2. Magnetic resonance imaging of hip joint cartilage and labrum

    Directory of Open Access Journals (Sweden)

    Christoph Zilkens

    2011-09-01

    Full Text Available Hip joint instability and impingement are the most common biomechanical risk factors that put the hip joint at risk to develop premature osteoarthritis. Several surgical procedures like periacetabular osteotomy for hip dysplasia or hip arthroscopy or safe surgical hip dislocation for femoroacetabular impingement aim at restoring the hip anatomy. However, the success of joint preserving surgical procedures is limited by the amount of pre-existing cartilage damage. Biochemically sensitive MRI techniques like delayed Gadolinium Enhanced MRI of Cartilage (dGEMRIC might help to monitor the effect of surgical or non-surgical procedures in the effort to halt or even reverse joint damage.

  3. RAZVOJ OBLAČIL V HIP HOP KULTURI

    OpenAIRE

    Marić, Sanja

    2010-01-01

    V diplomskem delu smo raziskovali, kako so se hip hop oblačila razvijala skozi obdobja v hip hop kulturi. V teoretičnem deli smo ugotavljali ozadje in dejavnike, ki so vplivali na razvoj hip hop kulture, v empiričnem delu diplomske naloge pa smo izvedli anketni vprašalnik z glavnimi akterji hip hop kulture na slovenski hip hop sceni. Rezultati, ki smo jih dobili, kažejo da so imela oblačila velik vpliv na prepoznavnost in razvoj hip hop kulture po celem svetu. K temu so največ pripomogli ustv...

  4. Hip morphologic measurements in an Egyptian population.

    Science.gov (United States)

    Aly, Tarek A

    2011-04-11

    The study of acetabular morphology has shown that there are geographic differences in the morphology and prevalence of acetabular dysplasia among different ethnic groups. However, few data exist on the shape of the acetabulum in various populations around the world. In this study, we examined samples of pelvic radiographs from Egyptian adults. Acetabular dysplasia in adults is characterized by a shallow and relatively vertical acetabulum.The aim of this study was to examine acetabular morphology to determine the prevalence of hip dysplasia in adult Egyptians. This included 244 adults, 134 men and 110 women between 18 and 60 years, who were used to measure center edge angle, acetabular Sharp angle, acetabular head index on anteroposterior radiographic views of the hip joints, and vertical center anterior margin angle on false profile views. The radiographs were taken of patients with no hip complaints at Tanta University Hospital.The results were statistically studied according to the age, height, and weight of patients. The prevalence of acetabular dysplasia was 2.25% for Egyptian men and 3.6% for women with respect to center edge angles, vertical center anterior margin angle, and acetabular head index.We concluded that gender variations in the morphology of the acetabulum and sex influences geometrical measurements of the acetabulum. Egyptian women were more dysplastic than men using the 4 parameters of hip measurements. There are also racial variations in hip morphology. Copyright 2011, SLACK Incorporated.

  5. Schizophrenia, antipsychotics and risk of hip fracture

    DEFF Research Database (Denmark)

    Sørensen, Holger J; Jensen, Signe O W; Nielsen, Jimmi

    2013-01-01

    In a nationwide study using linkage of Danish hospital registers we examined predictors of hip fracture (ICD-10: S72) in 15,431 patients with schizophrenia (ICD-10: F20 or ICD-8: 295) and 3,807,597 population controls. Shorter education, disability pension, lifetime alcohol abuse, somatic co......-morbidity, antipsychotics (IRR=1.19; 95% CI 1.15-1.24), antidepressant (IRR=1.18; 95% CI 1.16-1.20), anticholinergics (IRR=1.29; 95% CI 1.22-1.36), benzodiazepines (IRR=1.06; 95% CI 1.04-1.08) and corticosteroids (IRR=1.44; 95% CI 1.36-1.53) were significant predictors. In 556 persons with schizophrenia and hip fracture...... (matched to 1:3 to schizophrenia controls without hip fracture), antipsychotic polypharmacy predicted hip fracture. Analyses among antipsychotic monotherapy patients showed no differential effect of individual antipsychotics. A dose-response relationship of hip fracture and lifetime antipsychotics...

  6. Cystic lesion around the hip joint

    Science.gov (United States)

    Yukata, Kiminori; Nakai, Sho; Goto, Tomohiro; Ikeda, Yuichi; Shimaoka, Yasunori; Yamanaka, Issei; Sairyo, Koichi; Hamawaki, Jun-ichi

    2015-01-01

    This article presents a narrative review of cystic lesions around the hip and primarily consists of 5 sections: Radiological examination, prevalence, pathogenesis, symptoms, and treatment. Cystic lesions around the hip are usually asymptomatic but may be observed incidentally on imaging examinations, such as computed tomography and magnetic resonance imaging. Some cysts may enlarge because of various pathological factors, such as trauma, osteoarthritis, rheumatoid arthritis, or total hip arthroplasty (THA), and may become symptomatic because of compression of surrounding structures, including the femoral, obturator, or sciatic nerves, external iliac or common femoral artery, femoral or external iliac vein, sigmoid colon, cecum, small bowel, ureters, and bladder. Treatment for symptomatic cystic lesions around the hip joint includes rest, nonsteroidal anti-inflammatory drug administration, needle aspiration, and surgical excision. Furthermore, when these cysts are associated with osteoarthritis, rheumatoid arthritis, and THA, primary or revision THA surgery will be necessary concurrent with cyst excision. Knowledge of the characteristic clinical appearance of cystic masses around the hip will be useful for determining specific diagnoses and treatments. PMID:26495246

  7. [Clinical pathway for hip fracture patients].

    Science.gov (United States)

    Sáez López, Pilar; Sánchez Hernández, Natalia; Paniagua Tejo, Sonsoles; Valverde García, José Antonio; Montero Díaz, Margarita; Alonso García, Noelia; Freites Esteve, Alfonso

    2015-01-01

    Hip fracture in the elderly often occurs in patients with high co-morbidity. Effective management requires a comprehensive and multidisciplinary approach. To evaluate the effect of a quality improvement intervention in the detection and treatment of complications in elderly patients admitted for hip fracture. A comparative study was conducted between two groups of patients admitted for hip fracture prior to 2010, and after a quality improvement intervention in 2013. The intervention consisted of implementing improved multidisciplinary measures in accordance with recent scientific evidence. The degree of compliance of the implemented measures was quantified. Patients admitted due to hip fracture in 2010 (216 patients) and 2013 (196 patients) were similar in age, sex, Barthel Index, and a reduced Charlson Index, although there were more comorbidities in 2013. After implementation of the protocols, the detection of delirium, malnutrition, anemia, and electrolyte disturbances increased. A larger number of patients in 2013 were precribed intravenous iron (24% more) and osteoporosis treatment (61.3% more). The average stay was reduced by 45.3% and surgical delay by 29.4%, achieving better functional efficiency. The implementation of a clinical pathway in geriatric patients with hip fracture is useful to detect and treat complications at an early stage, and to reduce pre-operative and overall stay, all without a negative clinical or functional impact. Copyright © 2014 SEGG. Published by Elsevier Espana. All rights reserved.

  8. Concomitant Hip Arthroscopy and Periacetabular Osteotomy.

    Science.gov (United States)

    Domb, Benjamin G; LaReau, Justin M; Hammarstedt, Jon E; Gupta, Asheesh; Stake, Christine E; Redmond, John M

    2015-11-01

    To detail our early experience using concomitant hip arthroscopy and periacetabular osteotomy (PAO) for the treatment of acetabular dysplasia. We prospectively collected and retrospectively reviewed the surgical and outcome data of 17 patients who underwent concomitant hip arthroscopy and PAO between October 2010 and July 2013. Preoperative and postoperative range of motion, outcome and pain scores, and radiographic data were collected. Intraoperative arthroscopic findings and postoperative complications were recorded. The group consisted of 3 male and 14 female patients with a mean follow-up period of 2.4 years. Three patients had undergone previous surgery on the affected hip. Chondrolabral pathology was identified in all 17 patients. Twelve patients underwent labral repair, and five patients underwent partial labral debridement. No patient was converted to total hip arthroplasty or required revision surgery at short-term follow-up. All 4 patient-reported outcome scores showed statistically significant changes from baseline to latest follow-up (P arthroscopy and PAO has been favorable. We noted that all our patients have evidence of chondrolabral damage at the time of PAO when the joint is distracted and evaluated. All patients in this series had intra-articular pathology treated arthroscopically and showed satisfactory mean clinical improvement. Hip arthroscopy with PAO did not appear to introduce complications beyond the PAO alone. Level IV, therapeutic case series. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. Hip and Groin Injuries in Baseball Players.

    Science.gov (United States)

    Mlynarek, Ryan A; Coleman, Struan H

    2018-03-01

    To discuss the clinical significance of the most common hip and groin injuries in baseball players, as well as an algorithmic approach to diagnosis and treatment of these injuries. (a) Limitations in throwing velocity, pitch control, and bat swing speed may be secondary to decreased mobility and strength within the proximal kinetic chain, which must harness power from the lower extremities and core. (b) Approximately 5.5% of all baseball injuries per year involve the hip/groin and may lead to a significant amount of time spent on the disabled list. Injuries involving the hip and groin are relatively common in baseball players. Our knowledge of the mechanics of overhead throwing continues to evolve, as does our understanding of the contribution of power from the lower extremities and core. It is paramount that the team physician be able to accurately diagnose and treat injuries involving the hip/groin, as they may lead to significant disability and inability to return to elite levels of play. This review focuses on hip- and groin-related injuries in the baseball player, including femoroacetabular impingement, core muscle injury, and osteitis pubis.

  10. Screening for congenital dislocation of the hip

    International Nuclear Information System (INIS)

    Fendel, H.

    1987-01-01

    Although the prevalence of (idiopathic) congenital dislocation of the hip (CDH) within the Member States of the European Community is not exactly known, it must be considered as a major problem of public health care and protection. By assessment of available data one can assume that between 1 and 2% of all newborns have dislocation or instability of one or both hips. There is a female predominance of 4:1 and some risk factors are known. The reasons of a higher prevalence in some areas are not yet well understood. Most of instable hips will spontaneously become stable within the first days or weeks of life. However, a considerable number of infants (less than 1%) will remain with instable hips which may dislocate. Dislocation either present at birth or as a result of persistent instability leads to subsequent hip deformation. This is a serious event for each affected individual, and is a heavy load on health care and social costs for the public. Treatment of CDH is easy and usually effective when started early, i.e. before the fourth month of life. The earlier treatment is started the easier, shorter, safer and less expensive it is and its impairment on child development and mother-child interaction can be held to a minimum. Screening for CDH is therefore the most important part of health protection in early infancy. However, this paper concludes that neither sonography nor X-ray examinations are appropriate for CDH screening

  11. Hip arthroscopy: prevalence of intra-articular pathologic findings after traumatic injury of the hip.

    Science.gov (United States)

    Khanna, Vickas; Harris, Adam; Farrokhyar, Forough; Choudur, Hema N; Wong, Ivan H

    2014-03-01

    The purpose of this study was to document and compare the incidence of intra-articular hip pathologic findings identified using arthroscopy versus conventional imaging in patients with acute trauma to the hip. This was a blinded prospective case series study designed to review the incidence of intra-articular pathologic disorders in patients with post-traumatic injury between the ages of 18 and 65 years who were referred to a single surgeon. Injuries included hip dislocation, proximal femur fracture, pelvic ring fracture, acetabular fracture, penetrating injury (gunshot wound), and soft tissue injury. Preoperative radiographs, computed tomographic (CT) scans, or magnetic resonance imaging/magnetic resonance angiography (MRI/MRA) scans (or a combination of these) were obtained. Findings were documented and compared with intraoperative findings. A total of 29 post-traumatic hips were enrolled in this study. Hip arthroscopy identified 17 of 29 hips (59%) as having loose bodies, 11 of 29 (38%) hips as having an intra-articular step deformity, 14 of 29 (49%) hips as having an osteochondral lesion, and 27 of 29 (93%) hips as having a labral tear. Plain radiographs and CT scans yielded low sensitivity when compared with arthroscopy for the identification of loose bodies and step deformities. MRI/MRA comparison with arthroscopic findings suggest that MRI/MRA is an accurate tool for identification of labral tears, because 91% of tears seen on arthroscopy were also identified by MRI/MRA. In 4 hips, however, MRI/MRA failed to identify osteochondral lesions that were subsequently identified by arthroscopy. Traumatic injuries of the hip result in substantial intra-articular pathologic findings, including loose bodies, labral tears, step deformities, and osteochondral lesions. The arthroscope is a powerful tool in identifying these injuries. Plain radiographs and CT scans appear to underestimate the true incidence of loose bodies and step deformities within the joint when

  12. Perioperative glucocorticoids in hip and knee surgery - benefit vs. harm?

    DEFF Research Database (Denmark)

    Lunn, T H; Kehlet, H

    2013-01-01

    with systemic glucocorticoid. Pain was reduced with high-dose systemic and local glucocorticoid, but not with low-dose systemic glucocorticoid. Systemic inflammatory markers were reduced with low-dose and high-dose systemic glucocorticoid, and with local glucocorticoid. Functional recovery was improved...... with local glucocorticoid. All studies were small-sized and none sufficiently powered to meaningfully evaluate uncommon adverse events. Most of the local administration studies had poor scientific quality (high risk of bias). Due to clinical heterogeneity and poor scientific quality, no meta......-analysis was performed. In conclusion, in addition to PONV reduction with low-dose systemic glucocorticoid, this review supports high-dose systemic glucocorticoid to ameliorate post-operative pain after hip and knee surgery. However, large-scale safety and dose-finding studies are warranted before final recommendations....

  13. Abnormal hip physical examination findings in asymptomatic female soccer athletes

    Science.gov (United States)

    Hunt, Devyani; Rho, Monica; Yemm, Ted; Fong, Kathryn; Brophy, Robert H.

    2016-01-01

    Purpose Examination of the hip provides information regarding risk for pre-arthritic hip disorders, knee injuries, and low back pain. The purpose of this study was to report a hip screening examination of asymptomatic female soccer athletes and to test the hypothesis that these findings vary by competition experience. Methods Asymptomatic females from a youth soccer club, a college, and a professional team were evaluated. Passive hip range of motion, hip abduction strength, and hip provocative tests were assessed. Data were compared for the grade/middle school, high school, college, and professional athletes. Results One hundred and seventy-two athletes with a mean age of 16.7 ± 5 years (range 10–30) participated. Professional athletes had less flexion (HF) for both hips (p hips as compared to all other groups (p hip abduction strength as compared to other groups (p hip tests were found in 22 % of all players and 36 % of the professionals. In professionals, a positive provocative test was associated with ipsilateral decreased HF (p = 0.04). Conclusion Asymptomatic elite female soccer athletes with the most competition experience had less bilateral hip flexion and preferred kicking leg IR than less-experienced athletes. Positive provocative hip tests were found in 22 % of athletes. Future studies are needed to show whether these findings link to risk for intra-articular hip or lumbar spine and knee disorders. Level of evidence III. PMID:24150125

  14. Prevalence of hip dislocation among children with cerebral palsy in regions with and without a surveillance programme: a cross sectional study in Sweden and Norway

    Directory of Open Access Journals (Sweden)

    Elkamil Areej I

    2011-12-01

    Full Text Available Abstract Background Hip dislocation is a serious complication among children with cerebral palsy (CP. The aim of this study was to compare the prevalence of hip dislocation among children with CP in an area providing regular care with an area providing hip surveillance services. Methods This is a cross-sectional study in seven Norwegian counties providing regular care and one Swedish healthcare region where a hip surveillance programme was introduced in 1994. Data were provided by the Norwegian Cerebral Palsy Register and the CP Register in Southern Sweden. Children born 1996 - 2003 with moderate to severe CP, defined as Gross Motor Classification System (GMFCS levels III - V, were included. In all, 119 Norwegian and 136 Swedish children fulfilled the criteria. In Norway, data on hip operations and radiographs of the hips were collected from medical records, while these data are collected routinely in the Swedish register. The hip migration percentage was measured on the recent radiographs. Hip dislocation was defined as a migration percent of 100%. Results The proportion of children at GMFCS levels III - V was 34% in the Norwegian and 38% in the Swedish population. In the Norwegian population, hip dislocation was diagnosed in 18 children (15.1%; CI: 9.8 - 22.6 compared with only one child (0.7%; 95% CI: 0.01 - 4.0 in Southern Sweden (p = Conclusions The surveillance programme reduced the number of hip dislocations and the proportion of children undergoing hip surgery was lower. However, with the surveillance programme the first operation was performed at a younger age. Our results strongly support the effectiveness of a specifically designed follow-up programme for the prevention of hip dislocation in children with CP.

  15. Finite element analysis for friction noise of simplified hip joint and its experimental validation

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Jae Hyun; Choi, Hoil; Kang, Jae Young [Div. of Mechanical and Automotive Engineering, College of Engineering, Kongju National University, Cheonan (Korea, Republic of)

    2016-08-15

    In a hip joint system, squeak noise often occurs due to friction between the ball and hemispherical cup. To analyze the dynamic instability induced by friction in the hip joint system, the dynamic ball joint model was constructed by using the finite element method. The results from stability analysis revealed that the mode-coupling type instability occurred for one bending mode and its adjacent composite mode with the axial and transverse displacements with the increase of friction coefficient. The vitro squeak test and vibration modal tests confirmed that squeak arose near the frequency of the mode pair.

  16. Finite-element analysis of failure of the Capital Hip designs.

    NARCIS (Netherlands)

    Janssen, D.; Aquarius, R.J.M.; Stolk, J.; Verdonschot, N.J.J.

    2005-01-01

    The Capital Hip implant was a Charnley-based system which included a flanged and a roundback stem, both of which were available in stainless steel and titanium. The system was withdrawn from the market because of its inferior performance. However, all four of the designs did not produce poor rates

  17. The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

    Science.gov (United States)

    Brokelman, Roy B G; Haverkamp, Daniel; van Loon, Corné; Hol, Annemiek; van Kampen, Albert; Veth, Rene

    2012-06-01

    INTRODUCTION: Patient satisfaction becomes more important in our modern health care system. The assessment of satisfaction is difficult because it is a multifactorial item for which no golden standard exists. One of the potential methods of measuring satisfaction is by using the well-known visual analogue scale (VAS). In this study, we validated VAS for satisfaction. PATIENT AND METHODS: In this prospective study, we studied 147 patients (153 hips). The construct validity was measured using the Spearman correlation test that compares the satisfaction VAS with the Harris hip score, pain VAS at rest and during activity, Oxford hip score, Short Form 36 and Western Ontario McMaster Universities Osteoarthritis Index. The reliability was tested using the intra-class coefficient. RESULTS: The Pearson correlation test showed correlations in the range of 0.40-0.80. The satisfaction VAS had a high correlation between the pain VAS and Oxford hip score, which could mean that pain is one of the most important factors in patient satisfaction. The intra-class coefficient was 0.95. CONCLUSIONS: There is a moderate to mark degree of correlation between the satisfaction VAS and the currently available subjective and objective scoring systems. The intra-class coefficient of 0.95 indicates an excellent test-retest reliability. The VAS satisfaction is a simple instrument to quantify the satisfaction of a patient after total hip arthroplasty. In this study, we showed that the satisfaction VAS has a good validity and reliability.

  18. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    Directory of Open Access Journals (Sweden)

    Haviv Barak

    2010-07-01

    Full Text Available Abstract Objective To assess the incidence of total hip arthroplasty (THA in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years. The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16% of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures.

  19. Results of hip arthroplasty using Paavilainen technique in patients with congenitally dislocated hip

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2014-01-01

    Full Text Available The purpose of the study was to analyze the medium- and long-term results of hip arthroplasty using Paavilainen technique in patients with the congenitally dislocated hip. Methods: From 2001 to 2012 180 operations were carried out were using the Paavilainen technique in 140 patients with high dislocation of the hip (Crowe IV. All patients were clinically evaluated using the Harris Hip Score (HHS, VAS and radiography. Statistical analysis was performed using the Pearson correlation coefficients, multiple regression analysis and classification trees analysis. Results: The average Harris score improved from preoperative 41.6 (40,3-43,5 to 79.3 (77,9-82,7 at final follow-up, and the difference was significant. Early complications were 9% (the most frequent were fractures of the proximal femur, later - 16.7% (pseudoarthrosis of the greater trochanter, 13.9%; disclocations-1,1%, aseptic loosening of the components - 1.7%, reoperation performed in 8.3% of cases. Such factors as age and limb length has statistically significant effect on functional outcomes. Established predictive model allows to get the best possible functional outcome in such patients with severe dysplasia. Conclusions: Total Hip arthroplasty using the Paavilainen technique is an effective method of surgical treatment in patients with the congenitally dislocated hip, but it is technically difficult operation with a high incidence of complications in comparison with standard primary total hip replacement.

  20. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    Science.gov (United States)

    2010-01-01

    Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440

  1. O perfil das internações do SUS para fratura osteoporótica de fêmur em idosos no Brasil: uma descrição do triênio 2006-2008 Characteristics of hospital admissions in the Unified National Health System for osteoporotic hip fracture in elderly people in Brazil, 2006-2008

    Directory of Open Access Journals (Sweden)

    Paula Chagas Bortolon

    2011-04-01

    Full Text Available A osteoporose é uma síndrome multifatorial do esqueleto, sendo a fratura de fêmur a mais séria consequência para idosos, devido à alta mortalidade e ao custo. Este trabalho descreveu as fraturas osteoporóticas de fêmur em idosos para o Brasil, no triênio 2006-2008. A Autorização de Internação Hospitalar (AIH foi utilizada como base secundária de dados e permitiu criar indicadores para fratura de fêmur em idosos. As proporções de idosos internados no Sistema Único de Saúde (SUS por esta causa chegaram a 1%. Os percentuais de internação e óbitos foram maiores no sexo feminino e aumentaram com a idade. Os gastos foram de aproximadamente 2% dos gastos do SUS para pessoas com 60 anos ou mais. A maioria das internações durou de um a sete dias; 50,1% ocorreram em hospitais filantrópicos; e 42,7% aconteceram fora do município de residência. Os resultados reforçam a necessidade de maior atenção para a osteoporose e mostram a relevância dos gastos públicos com internações de idosos por fratura osteoporótica de fêmur. A compreensão de tais internações auxilia a formulação de políticas de saúde para esta causa.Osteoporosis is a multifactorial syndrome of the skeletal system, and hip fracture is the most serious consequence for the elderly, due to the high mortality and cost. This article describes osteoporotic hip fractures in Brazilian elderly in 2006-2008. Secondary data were obtained from the Authorization Forms for Hospital Admissions (AIH and allowed the creation of indicators for hip fracture in elders. The proportion of elderly patients hospitalized for hip fractures in the Unified National Health System was 1%. The percentages of hospital admissions and deaths were higher in females, and increased with age. Hip fractures accounted for approximately 2% of health care expenditures for persons 60 years or older. Length of hospital stay ranged from one to seven days, 50.1% occurred in charity hospitals, and 42

  2. Wear mechanisms in ceramic hip implants.

    Science.gov (United States)

    Slonaker, Matthew; Goswami, Tarun

    2004-01-01

    The wear in hip implants is one of the main causes for premature hip replacements. The wear affects the potential life of the prosthesis and subsequent removals of in vivo implants. Therefore, the objective of this article is to review various joints that show lower wear rates and consequently higher life. Ceramics are used in hip implants and have been found to produce lower wear rates. This article discusses the advantages and disadvantages of ceramics compared to other implant materials. Different types of ceramics that are being used are reviewed in terms of the wear characteristics, debris released, and their size together with other biological factors. In general, the wear rates in ceramics were lower than that of metal-on-metal and metal-on-polyethylene combinations.

  3. Traumatic hip dislocation: early MRI findings

    International Nuclear Information System (INIS)

    Laorr, A.; Greenspan, A.; Anderson, M.W.; Moehring, H.D.; McKinley, T.

    1995-01-01

    Objective of this study was to present the spectrum of early magnetic resonance imaging (MRI) findings following traumatic dislocation of the femoral head, and to identify any associated injuries. Prospective MRI of both hips was performed on 18 patients within 5 weeks of a traumatic femoral head dislocation. The interval between the time of injury and the imaging studies ranged from 2 to 35 days. Posterior dislocation was present in 14 patients and anterior dislocation in 4 patients. In the majority of cases, we performed axial T1, coronal T1, and coronal T2 * (MPGR) sequences. MRI can effectively identify and quantify the muscle injury and joint effusion that invariably accompany traumatic hip dislocations. It is also useful for demonstrating trabecular bone contusion (trabecular injury) and iliofemoral ligament injury, which occur commonly with acute hip dislocation. (orig./VHE)

  4. HIP technologies for fusion reactor blankets fabrication

    International Nuclear Information System (INIS)

    Le Marois, G.; Federzoni, L.; Bucci, P.; Revirand, P.

    2000-01-01

    The benefit of HIP techniques applied to the fabrication of fusion internal components for higher performances, reliability and cost savings are emphasized. To demonstrate the potential of the techniques, design of new blankets concepts and mock-ups fabrication are currently performed by CEA. A coiled tube concept that allows cooling arrangement flexibility, strong reduction of the machining and number of welds is proposed for ITER IAM. Medium size mock-ups according to the WCLL breeding blanket concept have been manufactured. The fabrication of a large size mock-up is under progress. These activities are supported by numerical calculations to predict the deformations of the parts during HIP'ing. Finally, several HIP techniques issues have been identified and are discussed

  5. Acute cognitive dysfunction after hip fracture

    DEFF Research Database (Denmark)

    Bitsch, M S; Foss, N B; Kristensen, B B

    2006-01-01

    hip fracture surgery in an optimized, multimodal, peri-operative rehabilitation regimen. METHODS: One hundred unselected hip fracture patients treated in a well-defined, optimized, multimodal, peri-operative rehabilitation regimen were included. Patients were tested upon admission and on the second......BACKGROUND: Patients undergoing hip fracture surgery often experience acute post-operative cognitive dysfunction (APOCD). The pathogenesis of APOCD is probably multifactorial, and no single intervention has been successful in its prevention. No studies have investigated the incidence of APOCD after......, fourth and seventh post-operative days with the Mini Mental State Examination (MMSE) score. RESULTS: Thirty-two per cent of patients developed a significant post-operative cognitive decline, which was associated with several pre-fracture patient characteristics, including age and cognitive function...

  6. Osteoblastoma in the region of the hip

    Directory of Open Access Journals (Sweden)

    Chen-Yuan Yang

    2013-02-01

    Full Text Available Osteoblastoma occurring in the region of the hip is very rare, and vague symptoms with uncharacteristic radiographic features often lead to misdiagnosis. Because of radiographic and histological similarities, it must be carefully distinguished from osteoid osteoma, aneurysmal bone cyst, giant cell tumor, and osteosarcoma. Computed tomography is the preferred imaging modality as it is able to detect the nidus and images will not exhibit the flare phenomenon caused by surrounding inflammation seen with magnetic resonance imaging. For hip joint lesions in weight-bearing areas, intralesional curettage may achieve satisfactory outcomes as compared with wide resection. We herein report two cases of osteoblastoma in the hip region in which diagnosis was delayed that were successfully treated with curettage and followed by high-speed burring.

  7. Arthroscopic approach and anatomy of the hip.

    Science.gov (United States)

    Aprato, Alessandro; Giachino, Matteo; Masse, Alessandro

    2016-01-01

    Hip arthroscopy has gained popularity among the orthopedic community and a precise assessment of indications, techniques and results is constantly brought on. In this chapter the principal standard entry portals for central and peripheral compartment are discussed. The description starts from the superficial landmarks for portals placement and continues with the deep layers. For each entry point an illustration of the main structures encountered is provided and the principal structures at risk for different portals are accurately examined. Articular anatomical description is carried out from the arthroscope point of view and sub-divided into central and peripheral compartment. The two compartments are systematically analyzed and the accessible articular areas for each portal explained. Moreover, some anatomical variations that can be found in the normal hip are reported. The anatomical knowledge of the hip joint along with a precise notion of the structures encountered with the arthroscope is an essential requirement for a secure and successful surgery. Level of evidence: V.

  8. Resistance training is accompanied by increases in hip strength and changes in lower extremity biomechanics during running.

    Science.gov (United States)

    Snyder, Kelli R; Earl, Jennifer E; O'Connor, Kristian M; Ebersole, Kyle T

    2009-01-01

    Movement and muscle activity of the hip have been shown to affect movement of the lower extremity, and been related to injury. The purpose of this study was to determine if increased hip strength affects lower extremity mechanics during running. Within subject, repeated measures design. Fifteen healthy women volunteered. Hip abduction and external rotation strength were measured using a hand-held dynamometer. Three-dimensional biomechanical data of the lower extremity were collected during running using a high-speed motion capture system. Measurements were made before, at the mid-point, and after a 6-week strengthening program using closed-chain hip rotation exercises. Joint range of motion (rearfoot eversion, knee abduction, hip adduction, and internal rotation), eversion velocity, eversion angle at heel strike, and peak joint moments (rearfoot inversion, knee abduction, hip abduction, and external rotation) were analyzed using repeated measures analysis of variance (P knee abduction moment (P=0.05) decreased by 57% and 10%, respectively. The hip abductors and external rotators were strengthened, leading to an alteration of lower extremity joint loading which may reduce injury risk. These exercises could be used in the rehabilitation, or prevention, of lower extremity injuries.

  9. Validation of gait analysis with dynamic radiostereometric analysis (RSA) in patients operated with total hip arthroplasty.

    Science.gov (United States)

    Zügner, Roland; Tranberg, Roy; Lisovskaja, Vera; Shareghi, Bita; Kärrholm, Johan

    2017-07-01

    We simultaneously examined 14 patients with OTS and dynamic radiostereometric analysis (RSA) to evaluate the accuracy of both skin- and a cluster-marker models. The mean differences between the OTS and RSA system in hip flexion, abduction, and rotation varied up to 9.5° for the skin-marker and up to 11.3° for the cluster-marker models, respectively. Both models tended to underestimate the amount of flexion and abduction, but a significant systematic difference between the marker and RSA evaluations could only be established for recordings of hip abduction using cluster markers (p = 0.04). The intra-class correlation coefficient (ICC) was 0.7 or higher during flexion for both models and during abduction using skin markers, but decreased to 0.5-0.6 when abduction motion was studied with cluster markers. During active hip rotation, the two marker models tended to deviate from the RSA recordings in different ways with poor correlations at the end of the motion (ICC ≤0.4). During active hip motions soft tissue displacements occasionally induced considerable differences when compared to skeletal motions. The best correlation between RSA recordings and the skin- and cluster-marker model was found for studies of hip flexion and abduction with the skin-marker model. Studies of hip abduction with use of cluster markers were associated with a constant underestimation of the motion. Recordings of skeletal motions with use of skin or cluster markers during hip rotation were associated with high mean errors amounting up to about 10° at certain positions. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1515-1522, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Avascular necrosis in children with cerebral palsy after reconstructive hip surgery

    Science.gov (United States)

    Phillips, L.; Hesketh, K.; Schaeffer, E. K.; Andrade, J.; Farr, J.; Mulpuri, K.

    2017-01-01

    Abstract Purpose Progressive hip displacement is one of the most common orthopaedic pathologies in children with cerebral palsy (CP). Reconstructive hip surgery has become the standard treatment of care. Reported avascular necrosis (AVN) rates for hip reconstructive surgery in these patients vary widely in the literature. The purpose of this study is to identify the frequency and associated risk factors of AVN for reconstructive hip procedures. Methods A retrospective analysis was performed of 70 cases of reconstructive hip surgery in 47 children with CP, between 2009 and 2013. All 70 cases involved varus derotation osteotomy (VDRO), with 60% having combined VDRO and pelvic osteotomies (PO), and 21% requiring open reductions. Mean age at time of surgery was 8.82 years and 90% of patients were Gross Motor Function Classification System (GMFCS) 4 and 5. Radiographic dysplasia parameters were analysed at selected intervals, to a minimum of one year post-operatively. Severity of AVN was classified by Kruczynski's method. Bivar- iate statistical analysis was conducted using Chi-square test and Student's t-test. Results There were 19 (27%) noted cases of AVN, all radio- graphically identifiable within the first post-operative year. The majority of AVN cases (63%) were mild to moderate in severity. Pre-operative migration percentage (MP) (p = 0.0009) and post-operative change in MP (p = 0.002) were the most significant predictors of AVN. Other risk factors were: GMFCS level (p = 0.031), post-operative change in NSA (p = 0.02) and concomitant adductor tenotomy (0.028). Conclusion AVN was observed in 27% of patients. Severity of displacement correlates directly with AVN risk and we suggest that hip reconstruction, specifically VDRO, be performed early in the 'hip at risk' group to avoid this complication. PMID:29081846

  11. Avascular necrosis in children with cerebral palsy after reconstructive hip surgery.

    Science.gov (United States)

    Phillips, L; Hesketh, K; Schaeffer, E K; Andrade, J; Farr, J; Mulpuri, K

    2017-10-01

    Progressive hip displacement is one of the most common orthopaedic pathologies in children with cerebral palsy (CP). Reconstructive hip surgery has become the standard treatment of care. Reported avascular necrosis (AVN) rates for hip reconstructive surgery in these patients vary widely in the literature. The purpose of this study is to identify the frequency and associated risk factors of AVN for reconstructive hip procedures. A retrospective analysis was performed of 70 cases of reconstructive hip surgery in 47 children with CP, between 2009 and 2013. All 70 cases involved varus derotation osteotomy (VDRO), with 60% having combined VDRO and pelvic osteotomies (PO), and 21% requiring open reductions. Mean age at time of surgery was 8.82 years and 90% of patients were Gross Motor Function Classification System (GMFCS) 4 and 5. Radiographic dysplasia parameters were analysed at selected intervals, to a minimum of one year post-operatively. Severity of AVN was classified by Kruczynski's method. Bivar- iate statistical analysis was conducted using Chi-square test and Student's t-test. There were 19 (27%) noted cases of AVN, all radio- graphically identifiable within the first post-operative year. The majority of AVN cases (63%) were mild to moderate in severity. Pre-operative migration percentage (MP) (p = 0.0009) and post-operative change in MP (p = 0.002) were the most significant predictors of AVN. Other risk factors were: GMFCS level (p = 0.031), post-operative change in NSA (p = 0.02) and concomitant adductor tenotomy (0.028). AVN was observed in 27% of patients. Severity of displacement correlates directly with AVN risk and we suggest that hip reconstruction, specifically VDRO, be performed early in the 'hip at risk' group to avoid this complication.

  12. Dynamic ultrasound of the external snapping hip syndrome

    International Nuclear Information System (INIS)

    Choi, Yun Sun; Song, Baek Yong; Paik, Sang Hyun; Lee, Tae Gyu; Yoon, Yong Kyu; Lee, Sung Moon

    2002-01-01

    Snapping hip syndrome has been described as a hip pain accompanied by an audible snapping during motion of the hip or while walking. The variable causes of its external, internal, and intra-articular origins have been described. The most common extemal snapping hip has been associated with a thickened posterior border of the iliotibial band or of the anterior border of the gluteus maximus muscle slipping over the greater trochanter. The aim of this study was to evaluate the dynamic ultrasound findings of external snapping hip syndrome with review of the literature. We studied 5 patients (7 cases) with external snapping hip and pain over the greater trochanter during walking or hip motion (3 males and 2 females, age range, 14-32 years; mean, 19 years). Two patients reported bilateral snapping hips.

  13. Getting your home ready - knee or hip surgery

    Science.gov (United States)

    Hip or knee surgery - getting your home ready; Osteoarthritis - knee ... Cabrera JA, Cabrera AL. Total hip replacement. In: Frontera WR, Silver JK, Rizzo TD, eds. Essentials of Physical Medicine and Rehabilitation . 3rd ed. Philadelphia, PA: Elsevier Saunders; ...

  14. Iliotibial band syndrome following hip arthroscopy: An unreported complication

    Directory of Open Access Journals (Sweden)

    Roberto Seijas

    2016-01-01

    Conclusions: This is a newly described observation within followup of hip arthroscopy. These findings may help orthopedic surgeons when planning rehabilitation after hip arthroscopy, including stretching exercises to prevent this syndrome.

  15. Evaluation of the magnitude of hip joint deformation in subjects with avascular necrosis of the hip joint during walking with and without Scottish Rite orthosis.

    Science.gov (United States)

    Karimi, Mohammad Taghi; Mohammadi, Ali; Ebrahimi, Mohammad Hossein; McGarry, Anthony

    2017-02-01

    The femoral head in subjects with leg calve perthes disease (LCPD) is generally considerably deformed. It is debatable whether this deformation is due to an increase in applied loads, a decrease in bone mineral density or a change in containment of articular surfaces. The aim of this study was to determine the influence of these factors on deformation of the femoral head. Two subjects with LCPD participated in this study. Subject motion and the forces applied on the affected leg were recorded using a motion analysis system (Qualsis TM ) and a Kistler force plate. OpenSim software was used to determine joint contact force of the hip joint whilst walking with and without a Scottish Rite orthosis. 3D Models of hip joints of both subjects were produced by Mimics software. The deformation of femoral bone was determined by Abaqus. Mean values of the force applied on the leg increased while walking with the orthosis. There was no difference between bone mineral density (BMD) of the femoral bone of normal and LCPD sides (p-value>0.05) and no difference between hip joint contact force of normal and LCPD sides. Hip joint containment appeared to decrease follow the use of the orthosis. It can be concluded that the deformation of femoral head in LCPD may not be due to change in BMD or applied load. Although the Scottish Rite orthosis is used mostly to increase hip joint containment, it appears to reduce hip joint contact area. It is recommended that a similar study is conducted using a higher number of subjects. Copyright © 2016 IPEM. All rights reserved.

  16. Rehabilitation following hip arthroscopy - A systematic review

    Directory of Open Access Journals (Sweden)

    Jeffrey S Grzybowski

    2015-05-01

    Full Text Available CONTEXT: Rehabilitation following hip arthroscopy is an integral component of the clinical outcome of the procedure. Given the increase in quantity, complexity, and diversity of procedures performed, a need exists to define the role of rehabilitation following hip arthroscopy.OBJECTIVES: 1 To determine the current rehabilitation protocols utilized following hip arthroscopy in the current literature, 2 to determine if clinical outcomes are significantly different based on different post-operative rehabilitation protocols; and 3 to propose the best-available evidence-based rehabilitation program following hip arthroscopy.DATA SOURCES: Per PRISMA guidelines and checklist, Medline, SciVerse Scopus, SportDiscus, and Cochrane Central Register of Controlled Trials were searched.STUDY SELECTION: Level I-IV evidence clinical studies with minimum two-year follow-up reporting outcomes of hip arthroscopy with post-operative rehabilitation protocols described were included. DATA EXTRACTION: All study, subject, and surgery parameters were collected. All elements of rehabilitation were extracted and analyzed. Descriptive statistics were calculated. Study methodological quality was analyzed using the Modified Coleman Methodology Score (MCMS.RESULTS: 18 studies were included (2,092 subjects; 52% male, mean age 35.1 +/- 10.6 years, mean follow-up 3.2 +/- 1.0 years. Labral tear and femoroacetabular impingement were the most common diagnoses treated and labral debridement and femoral/acetabular osteochondroplasty the most common surgical techniques performed. Rehabilitation protocol parameters (weight-bearing, motion, strengthening, and return-to-sport were poorly reported. Differences in clinical outcomes were unable to be assessed given heterogeneity in study reporting. Time-, phase-, goal-, and precaution-based guidelines were extracted and reported.CONCLUSIONS: The current literature of hip arthroscopy rehabilitation lacks high-quality evidence to support a

  17. Patterns of postural deformity in non-ambulant people with cerebral palsy: what is the relationship between the direction of scoliosis, direction of pelvic obliquity, direction of windswept hip deformity and side of hip dislocation?

    Science.gov (United States)

    Porter, David; Michael, Shona; Kirkwood, Craig

    2007-12-01

    To investigate: (a) associations between the direction of scoliosis, direction of pelvic obliquity, direction of windswept deformity and side of hip subluxation/ dislocation in non-ambulant people with cerebral palsy; and (b) the lateral distribution of these postural asymmetries. Cross-sectional observational study. Posture management services in three centres in the UK. Non-ambulant people at level five on the gross motor function classification system for cerebral palsy. Direction of pelvic obliquity and lateral spinal curvature determined from physical examination, direction of windswept hip deformity derived from range of hip abduction/adduction, and presence/side of unilateral hip subluxation defined by hip migration percentage. A total of 747 participants were included in the study, aged 6-80 years (median 18 years 10 months). Associations between the direction of scoliosis and direction of pelvic obliquity, and between the direction of windswept hip deformity and side hip subluxation/dislocation were confirmed. A significant association was also seen between the direction of scoliosis and the direction of the windswept hip deformity (P<0.001) such that the convexity of the lateral spinal curve was more likely to be opposite to the direction of windsweeping. Furthermore, significantly more windswept deformities to the right (P=0.007), hips subluxed on the left (P=0.002) and lateral lumbar/lower thoracic spinal curves convex to the left (P=0.03) were observed. The individual asymmetrical postural deformities are not unrelated in terms of direction and not equally distributed to the left/right. A pattern of postural deformity was observed.

  18. Do hip prosthesis related infection codes in administrative discharge registers correctly classify periprosthetic hip joint infection?

    DEFF Research Database (Denmark)

    Lange, Jeppe; Pedersen, Alma B; Troelsen, Anders

    2015-01-01

    PURPOSE: Administrative discharge registers could be a valuable and easily accessible single-sources for research data on periprosthetic hip joint infection. The aim of this study was to estimate the positive predictive value of the International Classification of Disease 10th revision (ICD-10...... in future single-source register based studies, but preferably should be used in combination with alternate data sources to ensure higher validity....... decreased to 82% (95% CI: 72-89). CONCLUSIONS: Misclassification must be expected and taken into consideration when using administrative discharge registers for epidemiological research on periprosthetic hip joint infection. We believe that the periprosthetic hip joint infection diagnosis code can be of use...

  19. Ideologia hip-hopowa na przykładzie tekstów hip-hopowych

    OpenAIRE

    Kozłowska, Monika

    2012-01-01

    The article is asort of analysis of hip hop lyrics in the context of their importance for identity formation process of young generation. Rap music, as one of the elements of hip hop culture, is a kind of special innovation for its audience. With rising interest for this musical genre and hip hop culture the discussion on formulating the issues through the prism of rap music’s message has been increasing. The article presents certain aspects of making sense to the reality, w...

  20. Radiological evaluation of failed total hip replacement

    International Nuclear Information System (INIS)

    Raspa, V.; Aldrovandi, S.; Pompei, G.

    1988-01-01

    The retrospective study of 50 operated cases of cemented total hip replacement and a review of the literature enabled the authors to define the radiological features of the above-mentioned condition. These features include one or more of the following signs: calcar reabsorption, lacunar erosions, modified relatioships between the prosthesis components, sepsis and loosening, periarticular calcifications dislocation and fracture of prosthesis components. Careful evaluation of these radiological features is extremely important for both an early diagnosis of failed total hip replacement and the choice of an adequate surgical treatment

  1. Hip Arthroscopy: Common Problems and Solutions.

    Science.gov (United States)

    Casp, Aaron; Gwathmey, Frank Winston

    2018-04-01

    The use of hip arthroscopy continues to expand. Understanding potential pitfalls and complications associated with hip arthroscopy is paramount to optimizing clinical outcomes and minimizing unfavorable results. Potential pitfalls and complications are associated with preoperative factors such as patient selection, intraoperative factors such as iatrogenic damage, traction-related complications, inadequate correction of deformity, and nerve injury, or postoperative factors such as poor rehabilitation. This article outlines common factors that contribute to less-than-favorable outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Hip fracture in hospitalized medical patients

    OpenAIRE

    Zapatero Antonio; Barba Raquel; Canora Jesús; Losa Juan E; Plaza Susana; San Roman Jesús; Marco Javier

    2013-01-01

    Abstract Background The aim of the present study is to analyze the incidence of hip fracture as a complication of admissions to internal medicine units in Spain. Methods We analyzed the clinical data of 2,134,363 adults who had been admitted to internal medicine wards. The main outcome was a diagnosis of hip fracture during hospitalization. Outcome measures included rates of in-hospital fractures, length of stay and cost. Results A total of 1127 (0.057%) admittances were coded with an in-hosp...

  3. Innovations in the management of hip fractures.

    Science.gov (United States)

    Teasdall, Robert D; Webb, Lawrence X

    2003-08-01

    Hip fractures include fractures of the head, neck, intertrochanteric, and subtrochanteric regions. Head fractures commonly accompany dislocations. Neck fractures and intertrochanteric fractures occur with greatest frequency in elderly patients with a low bone mineral density and are produced by low-energy mechanisms. Subtrochanteric fractures occur in a predominantly strong cortical osseous region that is exposed to large compressive stresses. Implants used to address these fractures must accommodate significant loads while the fractures consolidate. Complications secondary to hip fractures produce significant morbidity and include infection, nonunion, malunion, decubitus ulcers, fat emboli, deep venous thrombosis, pulmonary embolus, pneumonia, myocardial infarction, stroke, and death.

  4. Hot-isostatic pressing (HIP). Pt. 2

    International Nuclear Information System (INIS)

    Bayer, E.; Moser, G.; Seilstorfer, H.

    1981-01-01

    After the description of the microstructure and strengthening mechanism of nickel- and cobalt-base superalloys, claims for the production of suitable powders for the HIP-technology are pointed out and methods to its realization are discussed. Taking the manufacture of turbine discs (ultrasonic form) as an example the possibilities of the near-net-shape-technology are shown. Investigations on mechanical properties and on microstructures are carried out to determine the effect of HIP-process-parameters on these features. (orig.) [de

  5. Total Hip Arthroplasty in Mucopolysaccharidosis Type IH

    Directory of Open Access Journals (Sweden)

    S. O'hEireamhoin

    2011-01-01

    Full Text Available Children affected by mucopolysaccharidosis (MPS type IH (Hurler Syndrome, an autosomal recessive metabolic disorder, are known to experience a range of musculoskeletal manifestations including spinal abnormalities, hand abnormalities, generalised joint stiffness, genu valgum, and hip dysplasia and avascular necrosis. Enzyme therapy, in the form of bone marrow transplantation, significantly increases life expectancy but does not prevent the development of the associated musculoskeletal disorders. We present the case of a 23-year-old woman with a diagnosis of Hurler syndrome with a satisfactory result following uncemented total hip arthroplasty.

  6. Dosimetric influence of hip prosthesis during radiotherapeutic treatment

    International Nuclear Information System (INIS)

    Gschwind, R.; Buffard, E.; Masset, H.; Makovicka, L.; David, C.; David, C.; Buffard, E.

    2008-01-01

    As the population become aged, many patients with hip prosthesis are treated for a pelvic cancer. The recommended ballistic must avoid to pass in the prosthesis, but sometimes it is inevitable. So it is essential to quantify with accuracy the dose modifications linked to the presence of metallic implant. The aim of this study is to analyze by Monte Carlo method these modifications in simple and complex models (anthropomorphic phantom) which take into account the geometry and the composition of the prosthesis and its coatings. Then, this methodology was used to study the behaviour of a treatment planning system in theses extreme conditions. (authors)

  7. Hip adduction and abduction strength profiles in elite soccer players

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Serner, Andreas; Petersen, Jesper

    2011-01-01

    An ipsilateral hip adduction/abduction strength ratio of more than 90%, and hip adduction strength equal to that of the contralateral side have been suggested to clinically represent adequate strength recovery of hip adduction strength in athletes after groin injury. However, to what extent side-......-to-side symmetry in isometric hip adduction and abduction strength can be assumed in soccer players remains uncertain....

  8. Direct costs of osteoporosis and hip fracture: an analysis for the Mexican Social Insurance Health Care System Costos directos de la osteoporosis y fracturas de cadera: un análisis para el sistema de salud mexicano

    Directory of Open Access Journals (Sweden)

    Fernando Carlos

    2009-01-01

    Full Text Available OBJECTIVE: To compare costs of diagnosis and annual treatment of osteoporosis and hip fracture between the Instituto Nacional de Rehabilitación (INR and the protocol used by the Seguro Popular de Salud (SPSS. METHODS: Direct costs gathered in a prospective study with real cases at the INR are presented, and then this data is re-analyzed with the methodology and protocol for the SPSS to estimate the costs of those cases if treated with the SPSS protocol. RESULTS: Important differences were found in the cost of hip fracture: the SPSS estimates ($37 363.73 MXN almost double the INR cost ($20 286.86 MXN . This discrepancy was caused by the different types of surgeries the INR and SPSS protocols call for (the SPSS assumes that all hip fractures will necessitate a hip replacement and the cost of subsequent hospitalization. A prospective study at the SPSS is needed to validate these results. CONCLUSIONS: Important differences were found between treatment of the same osteoporosis related problems at the INR and SPSS. We recommend revising the SPSS protocol to include less costly surgical treatments.OBJETIVO: Realizar una comparación de costos de diagnóstico y tratamiento anual de la osteoporosis y la fractura de cadera entre el Instituto Nacional de Rehabilitación (INR y el protocolo utilizado por el Seguro Popular de Salud (SPSS. MATERIAL Y MÉTODOS: Los costos directos obtenidos en un estudio prospectivo con casos reales en el INR fueron utilizados para realizar un escenario considerando la metodología y protocolo del SPSS para estimar los costos de este último. RESULTADOS: Existen diferencias importantes en el costo de la fractura de cadera utilizando el escenario de SPSS; los costos estimados en SPSS fueron casi del doble respecto al INR ($37 363.73 vs. $20 286.86 pesos. Las diferencias están dadas por el tipo y costo de la cirugía (el SPSS asume que todas las fracturas de cadera tengan un remplazo total de cadera y el costo de la

  9. Assessment of congruence and impingement of the hip joint in professional ballet dancers: a motion capture study.

    Science.gov (United States)

    Charbonnier, Caecilia; Kolo, Frank C; Duthon, Victoria B; Magnenat-Thalmann, Nadia; Becker, Christoph D; Hoffmeyer, Pierre; Menetrey, Jacques

    2011-03-01

    Early hip osteoarthritis in dancers could be explained by femoroacetabular impingements. However, there is a lack of validated noninvasive methods and dynamic studies to ascertain impingement during motion. Moreover, it is unknown whether the femoral head and acetabulum are congruent in typical dancing positions. The practice of some dancing movements could cause a loss of hip joint congruence and recurrent impingements, which could lead to early osteoarthritis. Descriptive laboratory study. Eleven pairs of female dancer's hips were motion captured with an optical tracking system while performing 6 different dancing movements. The resulting computed motions were applied to patient-specific hip joint 3-dimensional models based on magnetic resonance images. While visualizing the dancer's hip in motion, the authors detected impingements using computer-assisted techniques. The range of motion and congruence of the hip joint were also quantified in those 6 recorded dancing movements. The frequency of impingement and subluxation varied with the type of movement. Four dancing movements (développé à la seconde, grand écart facial, grand écart latéral, and grand plié) seem to induce significant stress in the hip joint, according to the observed high frequency of impingement and amount of subluxation. The femoroacetabular translations were high (range, 0.93 to 6.35 mm). For almost all movements, the computed zones of impingement were mainly located in the superior or posterosuperior quadrant of the acetabulum, which was relevant with respect to radiologically diagnosed damaged zones in the labrum. All dancers' hips were morphologically normal. Impingements and subluxations are frequently observed in typical ballet movements, causing cartilage hypercompression. These movements should be limited in frequency. The present study indicates that some dancing movements could damage the hip joint, which could lead to early osteoarthritis.

  10. patterns of knee, hip and hand osteoarthritis in kenyatta national

    African Journals Online (AJOL)

    studied to determine the prevalence of obesity in this cohort of patients. Results: A total of 201 patients with knee, hip or hand osteoarthritis were studied. Of these participants,. 77% had knee OA, 15% hip OA, 3% hand OA and 5% had combined knee and hip OA. Obese participants were 41% and 32% were overweight.

  11. Superior dislocation hip with anterior column acetabular fracture ...

    African Journals Online (AJOL)

    Superior variety of anterior dislocation of the hip is a rare injury. Its occurrence with acetabular fractures has been documented infrequently. We report a case of superior dislocation of the hip with anterior column acetabular fracture. Open reduction of the hip and internal fixation of the fracture was carried out using a twin ...

  12. Total hip replacement for Mseleni Joint Disease undertaken in a ...

    African Journals Online (AJOL)

    found that hip surgery in this setting is of great benefit to Mseleni Joint Disease ... Conclusions: Hip surgery in this setting is of great benefit to the Mseleni Joint Disease patients but further attention .... The total hip score was divided into pain.

  13. Hip-Hopping across China: Intercultural Formulations of Local Identities

    Science.gov (United States)

    Barrett, Catrice

    2012-01-01

    The linguistic dimensions of globalized hip-hop cannot be understood simply as a byproduct of English as an American export. As hip-hop mobilizes, it is common (and arguably necessary) for global hip-hop communities to struggle through purposeful, semiotically rooted dialectics over what constitutes "authentic" and respectable forms of…

  14. Septic Arthritis of The Hip Joint presenting as Acute Abdomen ...

    African Journals Online (AJOL)

    These cases illustrate the maxim that any painful movement of the hip joint with associated unexplained fever should raise suspicion of septic arthritis. The close relationship of the hip joint to the pelvis sometimes confuses hip diseases with pelvic pathologies. Key Words: Septic arthritis, acute abdomen, pathological ...

  15. Higher incidence of hip fracture in newly diagnosed schizophrenic ...

    African Journals Online (AJOL)

    Higher incidence of hip fracture in newly diagnosed schizophrenic patients in Taiwan. Hip fracture is a major public health concern due to its poor outcome and serious socioeconomic burden in older people (1). Evidence has shown that many factors are related to increased risk of hip fracture, but psychiatric diseases are ...

  16. Large strengthening effect of a hip-flexor training programme

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Bandholm, Thomas Quaade; Zebis, Mette

    2016-01-01

    PURPOSE: To investigate the effect on hip-flexion strength of a 6-week hip-flexor training programme using elastic bands as resistance. We hypothesized that the training group, compared to a control group, would increase their hip-flexion strength more. METHODS: Thirty-three healthy subjects (45 ...

  17. The Amsterdam Hip Protector Study: Compliance and determinants of compliance

    NARCIS (Netherlands)

    van Schoor, N.M.; Asma, G.; Smit, J.H.; Bouter, L.M.; Lips, P.T.A.M.

    2003-01-01

    Hip protectors appear to be effective in reducing the incidence of hip fractures. However, compliance is often poor. Therefore, the objective of this study was to examine the compliance and determinants of compliance with external hip protectors. A prospective study was performed in residents from

  18. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  19. Pain distribution in primary care patients with hip osteoarthritis

    DEFF Research Database (Denmark)

    Poulsen, Erik; Overgaard, Søren; Vestergaard, Jacob T

    2016-01-01

    BACKGROUND: Hip osteoarthritis (OA) is the most common diagnosis in primary care adult patients presenting with hip pain but pain location and pain distribution in primary care patients with hip OA have been reported inadequately. OBJECTIVE: To describe pain location and pain distribution...

  20. Revolutionizing Environmental Education through Indigenous Hip Hop Culture

    Science.gov (United States)

    Gorlewski, Julie; Porfilio, Brad J.

    2012-01-01

    Based upon the life histories of six Indigenous hip hop artists of the Beat Nation artist collective, this essay captures how Indigenous hip hop has the potential to revolutionize environmental education. Hip hop provides Indigenous youth an emancipatory space to raise their opposition to neocolonial controls of Indigenous territories that…

  1. Ensaios estáticos de flexão e rigidez em placas do tipo sistema dinâmico do quadril (DHS Static load test on dynamic hip system (DHS plates

    Directory of Open Access Journals (Sweden)

    Anderson Freitas

    2009-01-01

    Full Text Available OBJETIVO: Avaliar isolada e comparativamente placas do tipo sistema dinâmico do quadril (DHS de dois fabricantes nacionais, analisar estatisticamente seus resultados e demonstrar a falta de determinantes para sua fabricação. MÉTODOS: Foram realizados ensaios estáticos de flexão em cinco placas DHS do fabricante I (grupo I e em igual quantidade do mesmo modelo do fabricante II (grupo II, sendo todas fabricadas em aço inoxidável austenítico ASTM F 138, com quatro furos e angulação de 135º. Utilizou-se máquina servohidráulica MTS, modelo Test Star II®, com capacidade de carga de 10 toneladas e controle de deslocamento. Foram obtidos dados da carga aplicada (P em função do deslocamento vertical do pistão (L, cuja velocidade foi 5 mm/min. Os ensaios foram interrompidos após atingir a deflexão vertical máxima especificada pelas normas dos ensaios. RESULTADOS: Grupo I: resistência de flexão, 161,4 ± 17,2 kgf rigidez, 64,5 ± 1,8 kgf/mm, ductilidade, > 25,4 mm. Grupo II: resistência de flexão, 124,7 ± 4,4, rigidez 59,6 ± 2,3, ductilidade > 25,4 mm. Para análise estatística foi adotado o teste de Mann-Whitney e a determinação de significância foi de 5% (pOBJECTIVE: To evaluate, both individually and comparatively, dynamic hip system-type plates marketed by two local manufacturers, to statistically analyze its results and show the lack of parameters for its manufacturing. METHODS: Static tests of flexion were carried out in five DHS plates of the manufacturer I (I group I and in equal quantity of the same model of the manufacturer II (I group II, being all made in stainless austenitic ASTM F 138 steel, with four holes and a 135º angle. A servo-hydraulic MTS machine, Test Star II model, was used with a load capacity of 10 tons and dislocation control. The data were obtained from the applied load (P as a function of the vertical dislocation of the piston (L, whose speed was 5mm/min. The tests were shutdown after reaching

  2. Inter-joint coordination between hips and trunk during downswings: Effects on the clubhead speed.

    Science.gov (United States)

    Choi, Ahnryul; Lee, In-Kwang; Choi, Mun-Taek; Mun, Joung Hwan

    2016-10-01

    Understanding of the inter-joint coordination between rotational movement of each hip and trunk in golf would provide basic knowledge regarding how the neuromuscular system organises the related joints to perform a successful swing motion. In this study, we evaluated the inter-joint coordination characteristics between rotational movement of the hips and trunk during golf downswings. Twenty-one right-handed male professional golfers were recruited for this study. Infrared cameras were installed to capture the swing motion. The axial rotation angle, angular velocity and inter-joint coordination were calculated by the Euler angle, numerical difference method and continuous relative phase, respectively. A more typical inter-joint coordination demonstrated in the leading hip/trunk than trailing hip/trunk. Three coordination characteristics of the leading hip/trunk reported a significant relationship with clubhead speed at impact (r joint coordination strategies have the great potential to use a biomechanical guideline to improve the golf swing performance of unskilled golfers.

  3. [Hip fracture in older adults: prevalence and costs in two hospitals. Tabasco, Mexico, 2009].

    Science.gov (United States)

    Quevedo-Tejero, Elsy del Carmen; Zavala-González, Marco Antonio; Hernández-Gamas, Arianna del Carmen; Hernández-Ortega, Hilda María

    2011-01-01

    To determine hip fracture prevalence and direct healthcare costs in elderly users of the reference hospitals of the Mexican Institute of Social Insurance (IMSS by spanish initials) and Mexican Oils (PEMEX by spanish initials), from Villahermosa, Tabasco, Mexico, during 2009. This is a cross-sectional study. The information was based on the registers of surgical interventions and institutional reports of the elderly inpatients who had a registered attention in their institution. Descriptive statistical analysis was performed considering the following variables: age, gender, hip fracture type, occurrence month, direct healthcare cost. Out of 10,765 records of hospitalized elderly, 57 hip fracture cases were found (33 in the IMSS and 24 in PEMEX). Hip fracture prevalence was 0.5%, (IMSS 1.1% and PEMEX 0.3%), being more frequent in women and older than 69. The most frequent fracture type was the femur neck one (78.9%). The estimated cost of healthcare in the hospital per patient was USD 5,803 in the IMSS and USD 11,800 in PEMEX. The hip fracture prevalence was higher in the IMSS users. Estimated healthcare costs per patient were higher than the reported in other institutions of the of the mexican health national system.

  4. Hip joint kinetics in the table tennis topspin forehand: relationship to racket velocity.

    Science.gov (United States)

    Iino, Yoichi

    2018-04-01

    The purpose of this study was to determine hip joint kinetics during a table tennis topspin forehand, and to investigate the relationship between the relevant kinematic and kinetic variables and the racket horizontal and vertical velocities at ball impact. Eighteen male advanced table tennis players hit cross-court topspin forehands against backspin balls. The hip joint torque and force components around the pelvis coordinate system were determined using inverse dynamics. Furthermore, the work done on the pelvis by these components was also determined. The peak pelvis axial rotation velocity and the work done by the playing side hip pelvis axial rotation torque were positively related to the racket horizontal velocity at impact. The sum of the work done on the pelvis by the backward tilt torques and the upward joint forces was positively related to the racket vertical velocity at impact. The results suggest that the playing side hip pelvis axial rotation torque exertion is important for acquiring a high racket horizontal velocity at impact. The pelvis backward tilt torques and upward joint forces at both hip joints collectively contribute to the generation of the racket vertical velocity, and the mechanism for acquiring the vertical velocity may vary among players.

  5. Inpatient cost for hip fracture patients managed with an orthogeriatric care model in Singapore.

    Science.gov (United States)

    Tan, Lester Teong Jin; Wong, Seng Joung; Kwek, Ernest Beng Kee

    2017-03-01

    The estimated incidence of hip fractures worldwide was 1.26 million in 1990 and is expected to double to 2.6 million by 2025. The cost of care for hip fracture patients is a significant economic burden. This study aimed to look at the inpatient cost of hip fractures among elderly patients placed under a mature orthogeriatric co-managed system. This study was a retrospective analysis of 244 patients who were admitted to the Department of Orthopaedics of Tan Tock Seng Hospital, Singapore, in 2011 for hip fractures under a mature orthogeriatric hip fracture care path. Information regarding costs, surgical procedures performed and patient demographics was collected. The mean cost of hospitalisation was SGD 13,313.81. The mean cost was significantly higher for the patients who were managed surgically than for the patients who were managed non-surgically (SGD 14,815.70 vs. SGD 9,011.38; p 48 hours was SGD 2,716.63. Reducing the time to surgery and preventing pre- and postoperative complications can help reduce overall costs. A standardised care path that empowers allied health professionals can help to reduce perioperative complications, and a combined orthogeriatric care service can facilitate prompt surgical treatment. Copyright: © Singapore Medical Association

  6. The Formation of "Hip-Hop Academicus"--How American Scholars Talk about the Academisation of Hip-Hop

    Science.gov (United States)

    Soderman, Johan

    2013-01-01

    Social activism and education have been associated with hip-hop since it emerged in New York City 38 years ago. Therefore, it might not be surprising that universities have become interested in hip-hop. This article aims to highlight this "hip-hop academisation" and analyse the discursive mechanisms that manifest in these academisation…

  7. No clinical difference between large metal-on-metal total hip arthroplasty and 28-mm-head total hip arthroplasty?

    NARCIS (Netherlands)

    Zijlstra, Wierd P; van den Akker-Scheek, Inge; Zee, Mark J M; van Raay, Jos J A M

    2011-01-01

    PURPOSE: We aimed to test the claim of greater range of motion (ROM) with large femoral head metal-on-metal total hip arthroplasty. METHODS: We compared 28-mm metal-on-polyethylene (MP) total hip arthroplasty with large femoral head metal-on-metal (MM) total hip arthroplasty in a randomised clinical

  8. Editorial Commentary: Hip Arthroscopy Plays a Role in Painful Hip Resurfacing Arthroplasty but a Prearthroscopy Diagnosis Is Critical to Outcome.

    Science.gov (United States)

    Rossi, Michael J

    2016-03-01

    Whereas hip arthroscopy plays a role in the investigation and treatment of the painful hip resurfacing arthroplasty, a diagnosis before arthroscopy is critical to improved outcome. The rate of conversion to total hip arthroplasty jumps from 7% to 37% when a pre-arthroscopy diagnosis is not known. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. Featherless Dinosaurs and the Hip-Hop Simulacrum: Reconsidering Hip-Hop's Appropriateness for the Music Classroom

    Science.gov (United States)

    Kruse, Adam J.

    2016-01-01

    This article offers considerations for music teachers interested in including hip-hop music in their classrooms but who might feel concerned with or overwhelmed by issues of appropriateness. Two concerns related to hip-hop music are examined: language and negative social themes. Commercial interests in hip-hop music have created a simulacrum (or…

  10. vein thrombosis in elective hip replacement

    African Journals Online (AJOL)

    A consensus forum was convened to evaluate the economic considerations associated with prophylaxis against thrombo-embolic disease in patients undergoing hip replacement therapy in South Africa. This forum consists of orthopaedic surgeons, vascular surgeons and a statistician. Methods. The forum was instructed to ...

  11. Screening for Developmental Dysplasia of the Hip

    NARCIS (Netherlands)

    Boere-Boonekamp, Magdalena M.; Verkerk, Paul H.

    1998-01-01

    The success rates of screening programmes for Developmental Dysplasia of the Hip (DDH) vary widely. Studies on screening programmes for DDH based on a Medline search for the years 1966–1997 are reviewed. The percentage treated in most studies, especially those using ultrasound, are high and suggest

  12. Total hip reconstruction in acetabular dysplasia.

    NARCIS (Netherlands)

    Schller, H.M.; Dalstra, M.; Huiskes, R.; Marti, R.K.

    1993-01-01

    In acetabular dysplasia, fixation of the acetabular component of a cemented total hip prosthesis may be insecure and superolateral bone grafts are often used to augment the acetabular roof. We used finite element analysis to study the mechanical importance of the lateral acetabular roof and found

  13. Recommendations for hip fracture management in Slovenia

    Directory of Open Access Journals (Sweden)

    Radko Komadina

    2012-03-01

    Full Text Available Professional societies for traumatology, osteology and physiatrics have written the recommendations for management of acute hip fracture in the elderly in Slovenia, which include acute surgical treatment, medical rehabilitation and secondary prevention with treatment of osteoporosis. The recommendations were adopted by the Board for Surgery at the Ministry of Health of the Republic of Slovenia in June and September 2011.

  14. Uudised : Ooper. Hip-hop. Madonna

    Index Scriptorium Estoniae

    2005-01-01

    Rumeenia sopran Nelly Miricioiu Vincenzo Bellini ooperi "Norma" nimiosas Nederlandse Operas Amsaterdamis 7.-28. märtsini. 4. märtsil Tallinna klubis Hollywood üritusel "Hip-Hop Café" New Yorgi duo Camp Lo. Ameerika poplaulja Madonna võttis vastu filmirolli

  15. Complications of hip fractures: A review

    Science.gov (United States)

    Carpintero, Pedro; Caeiro, Jose Ramón; Carpintero, Rocío; Morales, Angela; Silva, Samuel; Mesa, Manuel

    2014-01-01

    Nowadays, fracture surgery represents a big part of the orthopedic surgeon workload, and usually has associated major clinical and social cost implications. These fractures have several complications. Some of these are medical, and other related to the surgical treatment itself. Medical complications may affect around 20% of patients with hip fracture. Cognitive and neurological alterations, cardiopulmonary affections (alone or combined), venous thromboembolism, gastrointestinal tract bleeding, urinary tract complications, perioperative anemia, electrolytic and metabolic disorders, and pressure scars are the most important medical complications after hip surgery in terms of frequency, increase of length of stay and perioperative mortality. Complications arising from hip fracture surgery are fairly common, and vary depending on whether the fracture is intracapsular or extracapsular. The main problems in intracapsular fractures are biological: vascularization of the femoral head, and lack of periosteum -a major contributor to fracture healing- in the femoral neck. In extracapsular fractures, by contrast, the problem is mechanical, and relates to load-bearing. Early surgical fixation, the role of anti-thromboembolic and anti-infective prophylaxis, good pain control at the perioperative, detection and management of delirium, correct urinary tract management, avoidance of malnutrition, vitamin D supplementation, osteoporosis treatment and advancement of early mobilization to improve functional recovery and falls prevention are basic recommendations for an optimal maintenance of hip fractured patients. PMID:25232517

  16. Contralateral Total Hip Arthroplasty After Hindquarter Amputation

    Directory of Open Access Journals (Sweden)

    Scott M. M. Sommerville

    2006-01-01

    Full Text Available We describe the management and outcome of a 62-year old lady who developed severe osteoarthritis of the hip, nine years after a hindquarter amputation for radiation-induced sarcoma of the contralateral pelvis. The difficulties of stabilising the pelvis intraoperatively and the problems of postoperative rehabilitation are outlined. The operation successfully relieved her pain and restored limited mobility.

  17. TOTAL HIP REPLACEMENTS AT KIKUYU HOSPITAL, KENYA

    African Journals Online (AJOL)

    equipments, few trained personnel and the high cost of implants. It is mainly in the ..... function more affected than the sensory a day after. There was a foot drop. .... 60: Issue 2, 217-. 220. 13. NIH Consensus Development Panel on Total Hip.

  18. Injury incidence in hip hop dance.

    Science.gov (United States)

    Ojofeitimi, S; Bronner, S; Woo, H

    2012-06-01

    Hip hop dance has rapidly become a popular international art form. There is limited information on injury patterns in this population. The purpose of this study was to determine injury incidence and patterns among three groups of hip hop dancers. Three hundred and twelve intermediate, advanced, and expert hip hop dancers were recruited at battles, dance conferences, clubs, and on dance related web sites within the United States and internationally. A Web-based survey was conducted over a 6-month period. Inclusion criteria included intermediate and advanced level dancers over the age of 13. Dancers were divided into three main categories: Breakers, Popper/Lockers, and New Schoolers. Separate analysis of variances were used to compare injury pattern differences between groups. Two hundred and thirty-two dancers reported a total of 738 injuries. Five hundred and six of these (sustained by 205 dancers) were time-loss (TL) injuries. Annual injury incidence was 237% (162% involving TL). Lower extremity injuries were 52% and upper extremity injuries 32% of total injuries. Breakers had a higher injury incidence compared with Popper/Lockers, and New Schoolers. Hip hop dancers report injury rates that are higher than other dance forms but similar to gymnastics. These dancers should be educated concerning injury prevention, biomechanics, and use of protective equipment. © 2010 John Wiley & Sons A/S.

  19. Symptoms of Nerve Dysfunction After Hip Arthroscopy

    DEFF Research Database (Denmark)

    Dippmann, Christian; Thorborg, Kristian; Kraemer, Otto

    2014-01-01

    PURPOSE: The primary purpose of this study was to analyze the rate, pattern, and severity of symptoms of nerve dysfunction after hip arthroscopy (HA) by reviewing prospectively collected data. The secondary purpose was to study whether symptoms of nerve dysfunction were related to traction time...

  20. Hip adductor muscle function in forward skating.

    Science.gov (United States)

    Chang, Ryan; Turcotte, Rene; Pearsall, David

    2009-09-01

    Adductor strain injuries are prevalent in ice hockey. It has long been speculated that adductor muscular strains may be caused by repeated eccentric contractions which decelerate the leg during a stride. The purpose of this study was to investigate the relationship of skating speed with muscle activity and lower limb kinematics, with a particular focus on the role of the hip adductors. Seven collegiate ice hockey players consented to participate. Surface electromyography (EMG) and kinematics of the lower extremities were measured at three skating velocities 3.33 m/s (slow), 5.00 m/s (medium) and 6.66 m/s (fast). The adductor magnus muscle exhibited disproportionately larger increases in peak muscle activation and significantly prolonged activation with increased speed. Stride rate and stride length also increased significantly with skating velocity, in contrast, hip, knee and ankle total ranges of motion did not. To accommodate for the increased stride rate with higher skating speeds, the rate of hip abduction increased significantly in concert with activations of adductor magnus indicating a substantial eccentric contraction. In conclusion, these findings highlight the functional importance of the adductor muscle group and hip abduction-adduction in skating performance as well as indirectly support the notion that groin strain injury potential increases with skating speed.

  1. The Philippine "Hip Hop Stick Dance"

    Science.gov (United States)

    Lewis, Lisa

    2012-01-01

    This article introduces a dance that blends the traditional cultural heritage of the Philippines with modern music and moves. "Hip Hop Stick Dance" incorporates Tinikling (the Philippine national dance) and Arnis (a Filipino style of martial arts) to create a contemporary combination of rhythm, dance, and fitness. It was designed to introduce…

  2. Structural differences between hip endoprostheses, and implications on a hip kinetics

    Directory of Open Access Journals (Sweden)

    Mirza Biščević

    2005-11-01

    Full Text Available We compared kinetic characteristic of unipolar, bipolar and total hip endoprostheses, implanted after dislocated femoral neck fracture. Ninety patients were divided into three groups (30 patients in each group; a group with unipolar partial hip endoprosthesis (UPEP, a group with bipolar partial hip endoprosthesis (BPEP and a group with total hip endoprosthesis (TEP. The patients from different groups were paired by parameters which could influence the long term functional result: follow up period, comorbidities, functional capabilities before injury, etc. After the average follow up 3.8 +/- 1.9 years, a measuring of range of hip motions (ROM was conducted. The largest mean amplitudes in flexion (104 degrees, extension (13 degrees, abduction (35 degrees and external rotation (38 degrees was achieved BPEP, the largest adduction (14 degrees was achieved UPEP, and internal rotation (34 degrees TEP. Differences in ROMs are partially related to the clinical parameters such as: level of the hip pain, gait pattern, age and rehabilitation period (P < 0.05. Measuring of ROMs is the most reliable part of the clinical exam and it does not depend on subjectivity of patient, as opposed to other clinical parameters (level of pain, walking distance, aids usage, etc. The results obtained are favorable for the bipolar hip endoprosthesis, and they can be related to the biomechanical differences between the three types of hip endoprostheses. Kinetic advantages of the BPEP as compared to the UPEP, can be explained by the BPEP's structure: two-level mobility and a thinner neck which delays impingement in the late motion phase. In comparison to the TEP, clinical advantages of the BPEP can be attributed to less extensive surgery and scarring.

  3. Utility of immediate postoperative hip MRI in developmental hip dysplasia: closed vs. open reduction.

    Science.gov (United States)

    Jadhav, Siddharth P; More, Snehal R; Shenava, Vinitha; Zhang, Wei; Kan, J Herman

    2018-04-25

    Magnetic resonance imaging (MRI) of the hips is being increasingly used to confirm hip reduction after surgery and spica cast placement for developmental dysplasia of the hip (DDH). To review a single institutional experience with post-spica MRI in children undergoing closed or open hip reduction and describe the utility of MRI in directing the need for re-intervention. Seventy-four patients (52 female, 22 male) who underwent post-spica hip MRI over a 6-year period were retrospectively reviewed. One hundred and seven hips were included. Data reviewed included age at intervention, gender, type of intervention performed, MRI findings, the need for re-intervention and the interval between interventions. Gender was compared between the closed and open reduction groups via the Fisher exact test. Age at the first procedure was compared via the Wilcoxon rank test. Rates of re-intervention after closed and open reduction were calculated and the reasons for re-intervention were reviewed. The mean age at the time of the first intervention was 16.4 months (range: 4 to 63 months). Mean age for the closed reduction group was 10.5 months (range: 4-24 months) and for the open reduction group was 23.7 months (range: 5-63 months), which was significant (P-value open reduction, MRI was useful in deciding re-intervention in only 1 (2%). This patient had prior multiple failed closed and open reductions at an outside institute. Post intervention hip spica MRI is useful in determining the need for re-intervention after closed hip reduction, but its role after open reduction is questionable.

  4. A Water Rehabilitation Program in Patients with Hip Osteoarthritis Before and After Total Hip Replacement

    OpenAIRE

    ?yp, Marek; Kaczor, Ryszard; Cabak, Anna; Tederko, Piotr; W?ostowska, Ewa; Stanis?awska, Iwona; Szypu?a, Jan; Tomaszewski, Wies?aw

    2016-01-01

    Background Pain associated with coxarthrosis, typically occurring in middle-aged and elderly patients, very commonly causes considerable limitation of motor fitness and dependence on pharmacotherapy. This article provides an assessment of a rehabilitation program with tailored water exercises in patients with osteoarthritis before and after total hip replacement. Material/Methods A total of 192 patients (the mean age 61.03?10.89) suffering from hip osteoarthritis (OA) were evaluated before an...

  5. [Hip Fracture--Epidemiology, Management and Liaison Service. Risk factor for hip fracture].

    Science.gov (United States)

    Fujiwara, Saeko

    2015-04-01

    Many risk factors have been identified for hip fracture, including female, advanced age, osteoporosis, previous fractures, low body weight or low body mass index, alcohol drinking, smoking, family history of fractures, use of glucocorticoid, factors related to falls, and bone strength. The factors related to falls are number of fall, frail, post stroke, paralysis, muscle weakness, anti-anxiety drugs, anti-depression drugs, and sedatives. Dementia and respiratory disease and others have been reported to be risk factors for secondary hip fracture.

  6. Invariant hip moment pattern while walking with a robotic hip exoskeleton.

    Science.gov (United States)

    Lewis, Cara L; Ferris, Daniel P

    2011-03-15

    Robotic lower limb exoskeletons hold significant potential for gait assistance and rehabilitation; however, we have a limited understanding of how people adapt to walking with robotic devices. The purpose of this study was to test the hypothesis that people reduce net muscle moments about their joints when robotic assistance is provided. This reduction in muscle moment results in a total joint moment (muscle plus exoskeleton) that is the same as the moment without the robotic assistance despite potential differences in joint angles. To test this hypothesis, eight healthy subjects trained with the robotic hip exoskeleton while walking on a force-measuring treadmill. The exoskeleton provided hip flexion assistance from approximately 33% to 53% of the gait cycle. We calculated the root mean squared difference (RMSD) between the average of data from the last 15 min of the powered condition and the unpowered condition. After completing three 30-min training sessions, the hip exoskeleton provided 27% of the total peak hip flexion moment during gait. Despite this substantial contribution from the exoskeleton, subjects walked with a total hip moment pattern (muscle plus exoskeleton) that was almost identical and more similar to the unpowered condition than the hip angle pattern (hip moment RMSD 0.027, angle RMSD 0.134, p<0.001). The angle and moment RMSD were not different for the knee and ankle joints. These findings support the concept that people adopt walking patterns with similar joint moment patterns despite differences in hip joint angles for a given walking speed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Correlation of Hip Fracture with Other Fracture Types: Toward a Rational Composite Hip Fracture Endpoint

    Science.gov (United States)

    Colón-Emeric, Cathleen; Pieper, Carl F.; Grubber, Janet; Van Scoyoc, Lynn; Schnell, Merritt L; Van Houtven, Courtney Harold; Pearson, Megan; Lafleur, Joanne; Lyles, Kenneth W.; Adler, Robert A.

    2016-01-01

    Purpose With ethical requirements to the enrollment of lower risk subjects, osteoporosis trials are underpowered to detect reduction in hip fractures. Different skeletal sites have different levels of fracture risk and response to treatment. We sought to identify fracture sites which cluster with hip fracture at higher than expected frequency; if these sites respond to treatment similarly, then a composite fracture endpoint could provide a better estimate of hip fracture reduction. Methods Cohort study using Veterans Affairs and Medicare administrative data. Male Veterans (n=5,036,536) aged 50-99 years receiving VA primary care between1999-2009 were included. Fractures were ascertained using ICD9 and CPT codes and classified by skeletal site. Pearson correlation coefficients, logistic regression and kappa statistics, were used to describe the correlation between each fracture type and hip fracture within individuals, without regards to the timing of the events. Results 595,579 (11.8%) men suffered 1 or more fractures and 179,597 (3.6%) suffered 2 or more fractures during the time under study. Of those with one or more fractures, rib was the most common site (29%), followed by spine (22%), hip (21%) and femur (20%). The fracture types most highly correlated with hip fracture were pelvic/acetabular (Pearson correlation coefficient 0.25, p<0.0001), femur (0.15, p<0.0001), and shoulder (0.11, p<0.0001). Conclusions Pelvic, acetabular, femur, and shoulder fractures cluster with hip fractures within individuals at greater than expected frequency. If we observe similar treatment risk reductions within that cluster, subsequent trials could consider use of a composite endpoint to better estimate hip fracture risk. PMID:26151123

  8. Patient reported outcomes in hip arthroplasty registries.

    Science.gov (United States)

    Paulsen, Aksel

    2014-05-01

    PROs are used increasingly in orthopedics and in joint registries, but still many aspects of use in this area have not been examined in depth. To be able to introduce PROs in the DHR in a scientific fashion, my studies were warranted; the feasibility of four often used PROs (OHS, HOOS, EQ-5D and SF-12) was examined in a registry context. Having the PROs in the target language is an absolute necessity, so I translated, cross-culturally adapted and validated a Danish language version of an often used PRO (OHS), since this PRO had no properly developed Danish language version. To minimize data loss and to maximize the data quality I validated our data capture procedure, an up to date AFP system, by comparing scannable, paper-based PROs, with manual single-key- and double-key entered data. To help further registry-PRO studies, I calculated the number of patients needed to discriminate between subgroups of age, sex, diagnosis, and prosthesis type for each of four often used PROs (OHS, HOOS, EQ-5D and SF-12), and to simplify the clinical interpretation of PRO scores and PRO change scores in PRO studies, I estimated MCII and PASS for two often used PROs (EQ-5D and HOOS). The feasibility study included 5,747 THA patients registered in the DHR, and I found only minor differences between the disease-specific and the generic PROs regarding ceiling and floor effects as well as discarded items. The HOOS, the OHS, the SF-12, and the EQ-5D are all appropriate PROs for administration in a hip registry. I found that group sizes from 51 to 1,566 were needed for subgroup analysis, depending on descriptive factors and choice of PRO. The AFP study included 200 THA patients (398 PROs, 4,875 items and 21,887 data fields), and gave excellent results provided use of highly structured questionnaires. OMR performed equally as well as manual double-key entering, and better than single-key entering. The PRO translation and validation study included 2,278 patients (and 212 patients for the test

  9. Phantom studies of triple photon absorptiometry and bone mineral measurement at a hip prosthesis

    International Nuclear Information System (INIS)

    Farrell, T.J.; Webber, C.E.

    1992-01-01

    The feasibility of using triple photon absorptiometry (TPA) for the measurement of bone mineral mass about a hip prosthesis was examined. A theoretical expression describing the variance of TPA measurements was verified using a triple photon source and phantom materials which simulate the soft tissue-bone mineral-metal prosthesis system. The expression for the variance was used to determine an optimized set of photon energies. It was shown that a precision of 3% could be obtained for reasonable measurement times using this optimized set of energies and that TPA should be a feasible approach for measurement of bone mineral about a hip prosthesis. (orig.)

  10. A Water Rehabilitation Program in Patients with Hip Osteoarthritis Before and After Total Hip Replacement.

    Science.gov (United States)

    Łyp, Marek; Kaczor, Ryszard; Cabak, Anna; Tederko, Piotr; Włostowska, Ewa; Stanisławska, Iwona; Szypuła, Jan; Tomaszewski, Wiesław

    2016-07-25

    BACKGROUND Pain associated with coxarthrosis, typically occurring in middle-aged and elderly patients, very commonly causes considerable limitation of motor fitness and dependence on pharmacotherapy. This article provides an assessment of a rehabilitation program with tailored water exercises in patients with osteoarthritis before and after total hip replacement. MATERIAL AND METHODS A total of 192 patients (the mean age 61.03±10.89) suffering from hip osteoarthritis (OA) were evaluated before and after total hip replacement (THR). The clinical study covered measurements of hip active ranges of motion (HAROM) and the forces generated by pelvis stabilizer muscles. Pain intensity was assessed according to analogue-visual scale of pain (VAS) and according to the Modified Laitinen Questionnaire. The patients were divided into 6 groups (4 treatment and 2 control). We compared 2 rehabilitation programs using kinesitherapy and low-frequency magnetic field. One of them also had specially designed exercises in the water. Statistical analysis was carried out at the significance level α=0.05. This was a cross-sectional study. RESULTS A positive effect of water exercises on a number of parameters was found in patients with OA both before and after total hip replacement surgery. We noted a significant reduction of pain (pwater exercises most significantly reduced pain in patients with OA before and after total hip replacement surgery. 2. Inclusion of water exercises in a rehabilitation program can reduce the use of medicines in patient with OA and after THR.

  11. Surgical Dislocation of the Hip for the Treatment of Pre-Arthritic Hip Disease.

    Science.gov (United States)

    Beaulé, Paul E; Singh, Amardeep; Poitras, Stéphane; Parker, Gillian

    2015-09-01

    The purpose of this study was to report the clinical results of surgical dislocation of the hip in the treatment of pre-arthritic hip disease. Between 2005 and 2010, eighty-two patients (89 hips) underwent a surgical dislocation of the hip at a mean age of 30.5 years (range 14.8-51.7); 10 females and 72 males. At a mean follow-up of 7.1 years (range 5-9.6) clinical function improved significantly. 6 patients were converted to total hip arthroplasty and 3 patients underwent an arthroscopy and an additional three patients had >1mm of joint space narrowing at latest follow-up giving us a 9-year cumulative Kaplan-Meier survivorship of 86.4% (CI, 79% to 94%). Thirty-four patients underwent internal fixation removal at a mean of 12.0 months (range 0.3-40.8 months). Although effective in the treatment of early hip disease, the surgical dislocation approach carries a high re-operation rate for removal of internal fixation; consequently, less invasive approaches should be considered for less complex deformities. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Probability and heritability estimates on primary osteoarthritis of the hip leading to total hip arthroplasty

    DEFF Research Database (Denmark)

    Skousgaard, Søren Glud; Hjelmborg, Jacob; Skytthe, Axel

    2015-01-01

    INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk and heritab......INTRODUCTION: Primary hip osteoarthritis, radiographic as well as symptomatic, is highly associated with increasing age in both genders. However, little is known about the mechanisms behind this, in particular if this increase is caused by genetic factors. This study examined the risk...... and heritability of primary osteoarthritis of the hip leading to a total hip arthroplasty, and if this heritability increased with increasing age. METHODS: In a nationwide population-based follow-up study 118,788 twins from the Danish Twin Register and 90,007 individuals from the Danish Hip Arthroplasty Register...... not have had a total hip arthroplasty at the time of follow-up. RESULTS: There were 94,063 twins eligible for analyses, comprising 835 cases of 36 concordant and 763 discordant twin pairs. The probability increased particularly from 50 years of age. After sex and age adjustment a significant additive...

  13. Persistently High Hip Circumference after Bariatric Surgery Is a Major Hurdle to Successful Hip Replacement

    Directory of Open Access Journals (Sweden)

    Menachem M. Meller

    2014-01-01

    Full Text Available The prevalence of class III obesity (BMI≥40 kg/m2 in black women is 18%. As class III obesity leads to hip joint deterioration, black women frequently present for orthopedic care. Weight loss associated with bariatric surgery should lead to enhanced success of hip replacements. However, we present a case of a black woman who underwent Roux-en-Y gastric bypass with the expectation that weight loss would make her a better surgical candidate for hip replacement. Her gastric bypass was successful as her BMI declined from 52.0 kg/m2 to 33.7 kg/m2. However, her hip circumference after weight loss remained persistently high. Therefore, at surgery the soft tissue tunnel geometry presented major challenges. Tunnel depth and immobility of the soft tissue interfered with retractor placement, tissue reflection, and surgical access to the acetabulum. Therefore a traditional cup placement could not be achieved. Instead, a hemiarthroplasty was performed. After surgery her pain and reliance on external support decreased. But her functional independence never improved. This case demonstrates that a lower BMI after bariatric surgery may improve the metabolic profile and decrease anesthesia risk, but the success of total hip arthroplasties remains problematic if fat mass in the operative field (i.e., high hip circumference remains high.

  14. Degeneration in dysplastic hips. A computer tomography study

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Rømer, Lone; Søballe, Kjeld

    2005-01-01

    BACKGROUND: Hip dysplasia is considered pre-osteoarthritic, causing degeneration in young individuals. OBJECTIVE: To determine the pattern of degenerative change in moderate to severely dysplastic hips in young patients. DESIGN AND PATIENTS: One hundred and ninety-three consecutively......-referred younger patients with hip pain believed to be caused by hip dysplasia constituted the study cohort. The average age was 35.5 years (range, 15-61 years). They were examined by close-cut transverse pelvic and knee computed tomography and antero-posterior radiographs (CT). We identified 197 hips...

  15. Comparison of the angles and corresponding moments in the knee and hip during restricted and unrestricted squats.

    Science.gov (United States)

    Lorenzetti, Silvio; Gülay, Turgut; Stoop, Mirjam; List, Renate; Gerber, Hans; Schellenberg, Florian; Stüssi, Edgar

    2012-10-01

    The aim of this study was to compare the angles and corresponding moments in the knee and hip during squats. Twenty subjects performed restricted and unrestricted squats with barbell loads that were 0, ¼, and ½ their body weight. The experimental setup consisted of a motion capture system and 2 force plates. The moments were calculated using inverse dynamics. During the unrestricted squats, the maximum moments in the knee were significantly higher, and those in the hip were significantly lower than during restricted squats. At the lowest position, the maximum knee flexion angles were approximately 86° for the restricted and approximately 106° for the unrestricted techniques, whereas the maximum hip flexion angle was between 95° and 100°. The higher moments in the hip during restricted squats suggest a higher load of the lower back. Athletes who aim to strengthen their quadriceps should consider unrestricted squats because of the larger knee load and smaller back load.

  16. Medical Cost Analysis of the Osteoporotic Hip Fractures

    Directory of Open Access Journals (Sweden)

    Savaş Çamur

    2015-12-01

    Full Text Available Objective: Osteoporotic hip fractures decrease the life expectancy for 20% about 20-50% of the patients become permanently dependent in terms of walking for the rest of their life. Life expectancy is increasing in Turkey in the last 20 years. We investigated the impact of osteoporotic hip fractures which increase the morbidity and mortality on the national economy. Materials and Methods: A total of 81 patients admitted to our emergency department with the diagnosis of femur intertrochanteric fracture and femoral neck fracture between 2008 and 2012 were included in this study. We retrospectively evaluated the medical records and the medical costs of these patients from hospital information management system. Results: Of the 81 patients 32 (39.6% males and 49 (60.4% females meeting the inclusion criteria were included in this study. The mean age was 80.1 years (range, 61-103. Twenty-three (27.5% patients had femoral neck fracture and 58 (72.5% patients had intertrochanteric femur fracture. The mean length of hospital stay was 13.4 days in intertrochanteric femur fracture and 15.5 days in femoral neck fracture; average of the total days of hospitalization of all patients was 13.9 days. The average treatment cost per patient was 5,912.36 TL for intertrochanteric fractures, 5,753.00 TL for neck fractures, and 5,863.09 TL for the whole patient population. Conclusion: Hip fracture is a substantial cause of morbidity and mortality in elderly. Taking preventive measures before the fracture occurs may help to prevent this problem which has a high cost treatment and which is a substantial burden for the national economy.

  17. TOTAL HIP REPLACEMENT IN LEGG-CALVÉ-PERTHES DISEASE

    DEFF Research Database (Denmark)

    Froberg, Lonnie; Christensen, Finn; Pedersen, Niels Wisbech

    2009-01-01

    INTRODUCTION Poor long-time results in patients with Legg-Calvé-Perthes disease (LCP) are most often due to degenerative hip disease. The purpose of this study was to investigate if patients with LCP have an increased rate of total hip replacement (THR) compared to sex- and age-matched persons....... MATERIAL AND METHODS 167 LCP patients presented to our institution from 1941 to 1962. All patients were treated conservatively by a Thomas splint. Retrospectively medical records and radiographs were retrieved. Data from the Danish Hip Replacement Register and the Registries of the National Board of Health...... to follow-up and 3) patients with previous surgery to pelvis or lower limbs. 135 patients (156 hips) were enrolled in this study and 32 patients (35 hips) were excluded. RESULTS 20 hips out of 156 hips in patients with LCP have had a THR. Mean age at operation for the women was 50 years and 44 years...

  18. Refractory pain following hip arthroscopy: evaluation and management

    Science.gov (United States)

    de SA, Darren L; Burnham, Jeremy M; Mauro, Craig S

    2018-01-01

    ABSTRACT With increased knowledge and understanding of hip pathology, hip arthroscopy is rapidly becoming a popular treatment option for young patients with hip pain. Despite improved clinical and radiographic outcomes with arthroscopic treatment, some patients may have ongoing pain and less than satisfactory outcomes. While the reasons leading to failed hip arthroscopy are multifactorial, patient selection, surgical technique and rehabilitation all play a role. Patients with failed hip arthroscopy should undergo a thorough history and physical examination, as well as indicated imaging. A treatment plan should then be developed based on pertinent findings from the workup and in conjunction with the patient. Depending on the etiology of failed hip arthroscopy, management may be nonsurgical or surgical, which may include revision arthroscopic or open surgery, periacetabular osteotomy or joint arthroplasty. Revision surgery may be appropriate in settings including, but not limited to, incompletely treated femoroacetabular impingement, postoperative adhesions, heterotopic ossification, instability, hip dysplasia or advanced degeneration. PMID:29423245

  19. Seasonality of service provision in hip and knee surgery: a possible contributor to waiting times? A time series analysis.

    Science.gov (United States)

    Upshur, Ross E G; Moineddin, Rahim; Crighton, Eric J; Mamdani, Muhammad

    2006-03-01

    The question of how best to reduce waiting times for health care, particularly surgical procedures such as hip and knee replacements is among the most pressing concern of the Canadian health care system. The objective of this study was to test the hypothesis that significant seasonal variation exists in the performance of hip and knee replacement surgery in the province of Ontario. We performed a retrospective, cross-sectional time series analysis examining all hip and knee replacement surgeries in people over the age of 65 in the province of Ontario, Canada between 1992 and 2002. The main outcome measure was monthly hospitalization rates per 100,000 population for all hip and knee replacements. There was a marked increase in the rate of hip and knee replacement surgery over the 10-year period as well as an increasing seasonal variation in surgeries. Highly significant (Fisher Kappa = 16.05, p Holidays and utilization caps appear to exert a significant influence on the rate of service provision. It is expected that waiting times for hip and knee replacement could be reduced by reducing seasonal fluctuations in service provision and benchmarking services to peak delivery. The results highlight the importance of system behaviour in seasonal fluctuation of service delivery.

  20. Seasonality of service provision in hip and knee surgery: A possible contributor to waiting times? A time series analysis

    Directory of Open Access Journals (Sweden)

    Upshur Ross EG

    2006-03-01

    Full Text Available Abstract Background The question of how best to reduce waiting times for health care, particularly surgical procedures such as hip and knee replacements is among the most pressing concern of the Canadian health care system. The objective of this study was to test the hypothesis that significant seasonal variation exists in the performance of hip and knee replacement surgery in the province of Ontario. Methods We performed a retrospective, cross-sectional time series analysis examining all hip and knee replacement surgeries in people over the age of 65 in the province of Ontario, Canada between 1992 and 2002. The main outcome measure was monthly hospitalization rates per 100 000 population for all hip and knee replacements. Results There was a marked increase in the rate of hip and knee replacement surgery over the 10-year period as well as an increasing seasonal variation in surgeries. Highly significant (Fisher Kappa = 16.05, p 2Autoreg = 0.85 seasonality was identified in the data. Conclusion Holidays and utilization caps appear to exert a significant influence on the rate of service provision. It is expected that waiting times for hip and knee replacement could be reduced by reducing seasonal fluctuations in service provision and benchmarking services to peak delivery. The results highlight the importance of system behaviour in seasonal fluctuation of service delivery.

  1. Comparative responsiveness of measures of pain and function after total hip replacement

    DEFF Research Database (Denmark)

    Nilsdotter, A K; Roos, Ewa M.; Westerlund, J P

    2001-01-01

    To compare the responsiveness of the Functional Assessment System (FAS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Medical Outcomes Study 36-item Short Form (SF-36) in patients with osteoarthritis (OA) scheduled for total hip replacement....

  2. Dysplasia epiphysealis multiplex - problems in diagnosis and treatment of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Karski, T.; Ostrowski, J.; Karski, J. [Akademia Medyczna, Lublin (Poland)

    1991-12-31

    Dysplasia epiphysealis multiplex (DEM) is a generalized affection of the skeletal system involving the hips, knees, feet, shoulders, elbows and hands as well as the spine. It presents complex diagnostic problems, especially in babies and small children, in whom the symptoms are not distinctly developed. From the clinical points of view, DEM has to be distinguished from Perthes` disease. (author). 5 refs.

  3. From Rhymes to Resistance: Hip-Hop as a Critical Lens in Promoting Socially Just Teaching

    Science.gov (United States)

    Shelby-Caffey, Crystal; Byfield, Lavern; Solbrig, Stephanie

    2018-01-01

    If an educator is to take a critical stance, teach students to do the same, and design lessons that engage students in thoughtful discussions and actions surrounding issues of social justice, then discussions of politics, race, culture, economics and systems of power are crucial to this work, and the use of hip-hop is a worthwhile endeavour. In…

  4. Periprosthetic hip joint infection with Aspergillus terreus: A clinical case and a review of the literature

    Directory of Open Access Journals (Sweden)

    Rachel Bartash

    2017-12-01

    Full Text Available Fungal periprosthetic joint infections due to Aspergillus species are rare but are associated with significant cost and morbidity. We present a case of Asperigillus terreus prosthetic joint infection of the hip. The patient was successfully treated with a prolonged course of systemic antifungals along with surgical management. Keywords: Fungal prosthetic joint infection, Aspergillus terreus

  5. Estimation of Human Hip and Knee Multi-Joint Dynamics Using the LOPES Gait Trainer

    NARCIS (Netherlands)

    Koopman, Hubertus F.J.M.; van Asseldonk, Edwin H.F.; van der Kooij, Herman

    2016-01-01

    In this study, we present and evaluate a novel method to estimate multi-joint leg impedance, using a robotic gait training device. The method is based on multi-input–multi-output system identification techniques and is designed for continuous torque perturbations at the hip and knee joint

  6. Cerebral oximetry during preoperative resuscitation in elderly patients with hip fracture

    DEFF Research Database (Denmark)

    Clemmesen, C G; Pedersen, L M; Hougaard, S

    2018-01-01

    This study explores the association between postadmission and intraoperative cerebral oxygenation (ScO2), reflecting systemic perfusion, and postoperative mortality and delirium. Forty elderly (age > 65 years) patients with hip fractures were included in this prospective observational study. The ...

  7. Usefulness of Arthroscopic Treatment of Painful Hip after Acetabular Fracture or Hip Dislocation.

    Science.gov (United States)

    Hwang, Jung-Taek; Lee, Woo-Yong; Kang, Chan; Hwang, Deuk-Soo; Kim, Dong-Yeol; Zheng, Long

    2015-12-01

    Painful hip following hip dislocation or acetabular fracture can be an important signal for early degeneration and progression to osteoarthritis due to intraarticular pathology. However, there is limited literature discussing the use of arthroscopy for the treatment of painful hip. The purpose of this retrospective study was to analyze the effectiveness and benefit of arthroscopic treatment for patients with a painful hip after major trauma. From July 2003 to February 2013, we reviewed 13 patients who underwent arthroscopic treatment after acetabular fracture or hip dislocation and were followed up for a minimum of 2 postoperative years. The degree of osteoarthritis based on the Tonnis classification pre- and postoperatively at final follow-up was determined. Clinical outcomes were evaluated using visual analogue scale for pain (VAS) and modified Harris hip score (MHHS), and range of motion (ROM) of the hip pre- and postoperatively at final follow-up. There were nine male and four female patients with a mean age at surgery of 28 years (range, 20 to 50 years). The mean follow-up period of the patients was 59.8 months (range, 24 to 115 months), and the mean interval between initial trauma and arthroscopic treatment was 40.8 months (range, 1 to 144 months). At the final follow-up, VAS and MHHS improved significantly from 6.3 and 53.4 to 3.0 and 88.3, respectively (p = 0.002 and p hip flexion, abduction, adduction, external rotation, and internal rotation as minor improvements from 113.1°, 38.5°, 28.5°, 36.5°, and 22.7° to 118.5°, 39.0°, 29.2°, 38.9°, and 26.5° were observed, respectively (p = 0.070, p = 0.414, p = 0.317, p = 0.084, and p = 0.136, respectively). None of the patients exhibited progression of osteoarthritis of the hip at the final follow-up. Arthroscopic treatment after acetabular fracture or hip dislocation is effective and delays the progression of traumatic osteoarthritis.

  8. The innovation trap: modular neck in total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Samo Karel Fokter

    2017-04-01

    Full Text Available Background: Innovations play the key role in the success of orthopaedic surgery. However, even minor modifications in the established concepts and proven designs may result in disasters. The endemic of modular femoral neck fracture (24 cases of about 4000 implanted in fully modular total hip arthroplasty, popular in our country for the last 20 years, seems to challenge us with such an unfortunate consequences. The aim of this report was to analyze the extent and the causes of the problem on the one hand and to propose possible solutions on the other.Methods: Literature search for problems associated with Profemur Z (or earlier versions with the same taper-cone design fully-modular femoral stem made of titanium alloy (Ti6Al4V was performed, and hip arthroplasty registries were searched to evaluate the failure rates of the mentioned design. Mechanisms of failure were studied to get in-depth understanding of this particular hip reconstruction device.Results: Since 2010 onwards, several case reports on catastrophic modular femoral neck fractures of Profemur Z were published. Te frst Slovenian case was described in 2012. The first two larger series with modular femoral neck fractures were published in 2016. Te Australian Joint Replacement Registry was the first to discover increased revision rates due to fractures of this hip reconstruction system. Public Agency of the Republic of Slovenia for Medicinal Products and Medical Devices (JAZMP received frst two reports regarding Profemur Z modular neck complication from abroad in 2010, the first Slovenian report was received in 2012, and altogether 7 reports from Slovenian hospitals were received until December 2016. Corrosion at the neck-taper interface, where two equal or different materials are subject to constant wear in the presence of body fluids, is assumed to be responsible for the unacceptable high failure rate.Conclusions: Manufacturers are responsible to produce and market only safe devices

  9. [SURGICAL HIP DISLOCATION APPROACH FOR TREATMENT OF FEMORAL HEAD FRACTURE].

    Science.gov (United States)

    Tang, Yanfeng; Liu, Youwen; Zhu, Yingjie; Li, Jianming; Li, Wuyin; Li, Qiyi; Jia, Yudong

    2015-11-01

    To discuss the value of surgical hip dislocation approach in the treatment of femoral head fracture. A retrospectively analysis was made on the clinical data of 15 patients with femoral head fractures treated through surgical hip dislocation approach between January 2010 and February 2013. There were 11 men and 4 women with an average age of 30.8 years (range, 15-63 years). The causes included traffic accident injury in 9 cases, falling injury from height in 5 cases, and sports injury in 1 case. According to Pipkin typing, 2 cases were rated as type I, 7 cases as type II, 1 case as type III, and 5 cases as type IV. The interval of injury and operation was 2-10 days (mean, 4.1 days). Reduction was performed in 10 patients within 6 hours after injury, and then bone traction was given for 4-6 weeks except 5 patients who received reduction in the other hospital. Primary healing of incision was obtained in all patients after surgery without complications of dislocation and lower limbs deep venous thrombosis. The mean follow-up time was 29.9 months (range, 25-36 months). During follow-up, there was no infection, breakage of internal fixation, or nonunion of femoral greater trochanter fracture. In 3 patients having necrosis of the femoral head, 2 had no obvious symptoms [staging as IIa and IIb respectively according to Association Research Circulation Osseous (ARCO) staging system], and 1 (stage IIIb) had nonunion of the femoral neck fracture, who underwent total hip arthroplasty (THA). In 4 patients having myositis ossificans (2 cases of grade I, 1 case of grade II, and 1 case of grade III based on Brooker grading), no treatment was given in 3 cases and the focus was removed during THA in 1 case. According to the Thompson-Epstein scale at last follow-up, the results were excellent in 9 cases, good in 3 cases, fair in 1 case, and poor in 2 cases, and the excellent and good rate was 80%. Surgical hip dislocation approach can not only protect the residual vessels of the

  10. Hip hop jako kulturní styl, jeho spicifika a vliv na teenagery

    OpenAIRE

    POSPÍŠIL, Jan

    2008-01-01

    This thesis involves history of hip hop, its specifics and elements, it talks about influence of hip hip subculture on teenagers and points to positive and negative aspects connected to this culture style. In this way is work sectionalized into chapters. First part talks about history of hip hop, connection between religion and hip hop and also about Czech hip hop. Second part specifies on main elements of hip hop culture as DJing, MCing, breakdance, beatbox and graffiti. Last part focuses on...

  11. Internal Medicine Hospitalists' Perceived Barriers and Recommendations for Optimizing Secondary Prevention of Osteoporotic Hip Fractures.

    Science.gov (United States)

    Tan, Eng Keong; Loh, Kah Poh; Goff, Sarah L

    2017-12-01

    Osteoporosis is a major public health concern affecting an estimated 10 million people in the United States. To the best of our knowledge, no qualitative study has explored barriers perceived by medicine hospitalists to secondary prevention of osteoporotic hip fractures. We aimed to describe these perceived barriers and recommendations regarding how to optimize secondary prevention of osteoporotic hip fracture. In-depth, semistructured interviews were performed with 15 internal medicine hospitalists in a tertiary-care referral medical center. The interviews were analyzed with directed content analysis. Internal medicine hospitalists consider secondary osteoporotic hip fracture prevention as the responsibility of outpatient physicians. Identified barriers were stratified based on themes including physicians' perception, patients' characteristics, risks and benefits of osteoporosis treatment, healthcare delivery system, and patient care transition from the inpatient to the outpatient setting. Some of the recommendations include building an integrated system that involves a multidisciplinary team such as the fracture liaison service, initiating a change to the hospital policy to facilitate inpatient care and management of osteoporosis, and creating a smooth patient care transition to the outpatient setting. Our study highlighted how internal medicine hospitalists perceive their role in the secondary prevention of osteoporotic hip fractures and what they perceive as barriers to initiating preventive measures in the hospital. Inconsistency in patient care transition and the fragmented nature of the existing healthcare system were identified as major barriers. A fracture liaison service could remove some of these barriers.

  12. DIFFICULTIeS OF TOTAL HIP REPLACEMENT IN PATIENTS WITH ANKYLOSING SPONDYLITIS (case report

    Directory of Open Access Journals (Sweden)

    R. M. Tikhilov

    2016-01-01

    Full Text Available A distinctive feature of patients with ankylosing spondylitis is the formation of hip ankylosis in an extremely unfavorable functional position combined with upset of sagittal balance of the body along with a thoracolumbar kyphosis. Treatment of these patients poses considerable technical difficulties and is often associated with complications. The authors report a clinical case of a female 40 years old patient with confirmed rhizomelic spondylitis. The patient mainly complained of fixed malposition of the right lower extremity (hip ankylosis in extreme 1450 flexion and 1500 abduction combined with a severe fixed spine deformity (thoracic kyphosis 920, lumbar lordosis 170. Considering significant sagittal balance disorder it was decided to go for a two-stage procedure. Total hip arthroplasty of the right joint was performed at the first stage. At the second stage the authors corrected thoracolumbar spinal deformity by Th12 (type PSO 4 and L2 (type PSO 3 wedge resections and converging resected vertebral bodies by a multilevel fixation system with transpedicular support elements. The interval between the stages was 11 months. Two-stage treatment of this patient al-lowed to avoid adverse postoperative complications and to achieve a significant functional improvement in one year after treatment started. The sum of points before and after the treat-ment amounted respectively to 46 and 79 on Harris Hip Score, 17 and 38 points on Oxford Hip Score (OHS. To summarize, comprehensive treatment with planning of all subsequent steps prior to hip replacement is the method of choice for avoidance of postoperative complications in patients with ankylosing spondylitis accompanied by a significant upset of sagittal balance.

  13. Magnetic resonance imaging findings compared with histological findings of the labrum in hip osteoarthritis

    International Nuclear Information System (INIS)

    Kanezaki, Shiho; Nakamura, Shigeru; Matsushita, Takashi; Yamamoto, Asako; Osawa, Marie

    2015-01-01

    Patients with disorders such as acetabular dysplasia or femoroacetabular impingement are at risk of developing hip osteoartbritis. Assessment of the cartilage and labrum in the hip joint based on magnetic resonance imaging (MRI) has been challenging because of the low signal-to-noise ratio (SNR) due to its deep location, ball and socket structure, and small volume of those structures compared with the whole joint size. To achieve better imaging assessment, direct MR. arthrography (d-MRA) and other techniques such as T2* mapping, T2 mapping, Tlrho, and delayed gadolinium-enhanced MRI (dGEMRIC) have been developed along with the increasing use of high-field MRI. In patients with no apparent osteoarthritic changes such as joint space narrowing or osteophyte and subchondral cyst formation on radiographs, these techniques can detect early cartilage or labral damage. A recently developed semiquantitative MRI-based scoring system for hip osteoarthritis includes evaluation of the labrum, and its application as a potential therapeutic monitoring tool is anticipated. The labrum shows pathological changes such as macroscopic hypertrophy and histological degeneration in hip osteoartbritis, but the pathological background is not well understood when evaluated by MRI. Kubo et al. compared radial MRI findings with histological changes of the labrum in ll hips with osteoarthritis using 1.5-T MRJ and found that fibrous separation and mucoid deposition occurred in the labrum with a ''diffuse high signal'' or ''obscure'' pattern. However, to the best of our knowledge, no studies have demonstrated a correlation between MRI fmdings and histological evidence of the severity of degeneration of the labrum. We hypothesized that radially reconstructed images of the acetabular labrum acquired by 3-T MRI can depict degenerative changes of the labrum. In this study, we sought to determine the correlation between MRI and histological findings of the

  14. Magnetic resonance imaging findings compared with histological findings of the labrum in hip osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kanezaki, Shiho; Nakamura, Shigeru; Matsushita, Takashi [Teikyo University School of Medicine, Department of Orthopaedic Surgery, Itabashi-ku, Tokyo (Japan); Yamamoto, Asako; Osawa, Marie [Teikyo University School of Medicine, Department of Radiology, Itabashi-ku, Tokyo (Japan)

    2015-06-01

    Patients with disorders such as acetabular dysplasia or femoroacetabular impingement are at risk of developing hip osteoartbritis. Assessment of the cartilage and labrum in the hip joint based on magnetic resonance imaging (MRI) has been challenging because of the low signal-to-noise ratio (SNR) due to its deep location, ball and socket structure, and small volume of those structures compared with the whole joint size. To achieve better imaging assessment, direct MR. arthrography (d-MRA) and other techniques such as T2* mapping, T2 mapping, Tlrho, and delayed gadolinium-enhanced MRI (dGEMRIC) have been developed along with the increasing use of high-field MRI. In patients with no apparent osteoarthritic changes such as joint space narrowing or osteophyte and subchondral cyst formation on radiographs, these techniques can detect early cartilage or labral damage. A recently developed semiquantitative MRI-based scoring system for hip osteoarthritis includes evaluation of the labrum, and its application as a potential therapeutic monitoring tool is anticipated. The labrum shows pathological changes such as macroscopic hypertrophy and histological degeneration in hip osteoartbritis, but the pathological background is not well understood when evaluated by MRI. Kubo et al. compared radial MRI findings with histological changes of the labrum in ll hips with osteoarthritis using 1.5-T MRJ and found that fibrous separation and mucoid deposition occurred in the labrum with a ''diffuse high signal'' or ''obscure'' pattern. However, to the best of our knowledge, no studies have demonstrated a correlation between MRI fmdings and histological evidence of the severity of degeneration of the labrum. We hypothesized that radially reconstructed images of the acetabular labrum acquired by 3-T MRI can depict degenerative changes of the labrum. In this study, we sought to determine the correlation between MRI and histological findings of the

  15. Management of acetabular fractures with modified posterior approach to spare external hip rotators.

    Science.gov (United States)

    Sarlak, Ahmet Y; Selek, Ozgur; Inanir, Murat; Musaoglu, Resul; Baran, Tuncay

    2014-04-01

    In the present study the quality of reduction and incidence of complications in hip external rotator sparing modified posterior approach was assessed in both simple and complex acetabular fractures. This retrospective study includes 37 patients (38 hips) with a mean age of 42.1 years (range 21-60), that had been treated for displaced acetabular fractures from June 2007 through May 2011. They were reviewed at a mean of 3 years (20-67 months). The fractures were classified according to the Letournel-Judet classification. Anatomic reduction and stable fixation of the fracture with less than 2mm residual displacement was achieved in 28 of 38 hips. At the final follow up the patients were evaluated clinically according to Merle d'Aubigne and Postel scoring system which had been modified by Matta and radiologically based on the criteria described by Matta. The clinical results were excellent in 20, good in 8, fair in 8, and poor 2 hips. Complications included two superficial local wound infection and 10 heterotopic ossification with 7 of the cases having grade I heterotopic ossification. Avascular necrosis of the femoral head was not seen in any of the 38 hips. One patient with preoperative sciatic nerve palsy had complete recovery of neurologic function. There were no cases of deep vein thrombosis or pulmonary embolism. The functional outcome was satisfactory in most of the cases and comparable with other larger series. Using the limited part of Henry's sciatic nerve exposure skin incision - working in the plane between gluteus maximus and the tensor fascia lata as in the classical Gibson approach and two portal external rotator hip sparing approach resulted in good fracture reduction without approach related complications. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Use of organic nitrates and the risk of hip fracture: a population-based case-control study.

    Science.gov (United States)

    Pouwels, Sander; Lalmohamed, Arief; van Staa, Tjeerd; Cooper, Cyrus; Souverein, Patrick; Leufkens, Hubertus G; Rejnmark, Lars; de Boer, Anthonius; Vestergaard, Peter; de Vries, Frank

    2010-04-01

    Use of organic nitrates has been associated with increased bone mineral density. Moreover, a large Danish case-control study reported a decreased fracture risk. However, the association with duration of nitrate use, dose frequency, and impact of discontinuation has not been extensively studied. Our objective was to evaluate the association between organic nitrates and hip fracture risk. A case-control study was conducted using the Dutch PHARMO Record Linkage System (1991-2002, n = 6,763 hip fracture cases and 26,341 controls). Cases had their first admission for hip fracture, whereas controls had not sustained any fracture after enrollment. Current users of organic nitrates were patients who had received a prescription within 90 d before the index date. The analyses were adjusted for disease and drug history. Current use of nitrates was not associated with a decreased risk of hip fracture [adjusted odds ratio (OR) = 0.93; 95% confidence interval (CI) = 0.83-1.04]. Those who used as-needed medication only had a lower risk of hip fracture (adjusted OR = 0.83; 95% CI = 0.63-1.08) compared with users of maintenance medication only (adjusted OR = 1.17; 95% CI = 0.97-1.40). No association was found between duration of nitrate use and fracture risk. Our overall analyses showed that risk of a hip fracture was significantly lower among users of as-needed organic nitrates, when compared with users of maintenance medication. Our analyses of hip fracture risks with duration of use did not further support a beneficial effect of organic nitrates on hip fracture, although residual confounding may have masked beneficial effects.

  17. Prometheus payment model: application to hip and knee replacement surgery.

    Science.gov (United States)

    Rastogi, Amita; Mohr, Beth A; Williams, Jeffery O; Soobader, Mah-Jabeen; de Brantes, Francois

    2009-10-01

    The Prometheus Payment Model offers a potential solution to the failings of the current fee-for-service system and various forms of capitation. At the core of the Prometheus model are evidence-informed case rates (ECRs), which include a bundle of typical services that are informed by evidence and/or expert opinion as well as empirical data analysis, payment based on the severity of patients, and allowances for potentially avoidable complications (PACs) and other provider-specific variations in payer costs. We outline the methods and findings of the hip and knee arthroplasty ECRs with an emphasis on PACs. Of the 2076 commercially insured patients undergoing hip arthroplasty in our study, PAC costs totaled $7.8 million (14% of total costs; n = 699 index PAC stays). Similarly, PAC costs were $12.7 million (14% of total costs; n = 897 index PAC stays) for 3403 patients undergoing knee arthroplasty. By holding the providers clinically and financially responsible for PACs, and by segmenting and quantifying the type of PACs generated during and after the procedure, the Prometheus model creates an opportunity for providers to focus on the reduction of PACs, including readmissions, making the data actionable and turn the waste related to PAC costs into potential savings.

  18. Impaired hip muscle strength in patients with femoroacetabular impingement syndrome.

    Science.gov (United States)

    Kierkegaard, Signe; Mechlenburg, Inger; Lund, Bent; Søballe, Kjeld; Dalgas, Ulrik

    2017-12-01

    Patients with femoroacetabular impingement (FAI) experience hip pain as well as decreased function and lowered quality of life. The aim was to compare maximal isometric and isokinetic muscle strength (MVC) during hip flexion and extension and rate of force development (RFD) during extension between patients with FAI and a matched reference group. Secondary, the aim was to compare patient hips and subgroups defined by gender and age as well as to investigate associations between hip muscle strength and self-reported outcomes. Design Cross-sectional, comparative study Methods Sixty patients (36±9 years, 63% females) and 30 age and gender matched reference persons underwent MVC tests in an isokinetic dynamometer. During hip flexion and extension, patients' affected hip showed a strength deficit of 15-21% (phip of the patients was significantly weaker than their contralateral hip. RFD was significantly decreased for both patient hips compared to the reference group (phip muscle strength. Patients with FAI demonstrate decreased hip flexion and extension strength when compared to (1) reference persons and (2) their contralateral hip. There seems to be a gender specific affection which should be investigated further and addressed when planning training protocols. Furthermore, self-reported measures were associated with isometric muscle strength, which underlines the clinical importance of the reduced muscle strength. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  19. CT findings of traumatic posterior hip dislocation after reduction

    International Nuclear Information System (INIS)

    Moon, Sung Kyoung; Park, Ji Seon; Ryu, Kyung Nam; Jin, Wook; Jin Wook

    2008-01-01

    To evaluate the CT images of reduced hips after posterior hip dislocation and to propose specific diagnostic criteria based on the CT results. We retrospectively reviewed the CT findings on 18 reduced hips from 17 patients with radiographs and clinical histories of traumatic posterior hip dislocations by evaluating 18 corresponding CT scans for joint space asymmetry, intra-articular abnormalities (intra-articular fat obliteration, loose bodies, and joint effusion), changes in posterior soft tissue (capsule, muscles, and adjacent fat), the presence, and location of fractures (acetabulum and femoral head). All 18 hips (100%) showed posterior soft tissue changes. In total, 17 hips (94.4%) had intra-articular abnormalities and 15 hips (83.3%) had joint space asymmetries. In addition, 17 hips (94.4%) had fractures involving the acetabula (15 cases, 88.2%) the femoral head (13 cases, 76.5%), or on both sides (11 cases, 64.7%). The most frequent fracture location was in he posterior wall (13/15, 86.7%) of the acetabulum and in the anterior aspect (10/13, 76.9%) of the femoral head. Patients with a prior history of posterior hip dislocation showed specific CT findings after reduction, suggesting the possibility of previous posterior hip dislocations in patients

  20. Relationship between flexible flat foot and developmental hip dysplasia.

    Science.gov (United States)

    Ponce de León Samper, M C; Herrera Ortiz, G; Castellanos Mendoza, C

    2015-01-01

    To evaluate the possible relationship between flexible flat foot and developmental hip dysplasia in children between six and 15 years of age. Cross-sectional study including 65 patients that had undergone surgery due to residual hip dysplasia or hip dislocation and compared against 75 healthy patients. Flexible flat foot prevalence was measured in each group, with the results showing that 61% of the group with residual hip dysplasia or hip dislocation had this condition, vs. 12% in the healthy group. The statistical analysis shows that the chances of suffering from flexible flat foot, are five times greater in the hip dysplasia or hip dislocation group, than in the healthy group. There is no evidence in the literature showing a relationship between these two conditions, even though they have a common etiology. This study shows a potential measurable relation between this two conditions. Patients with hip dysplasia or dislocation may have a higher chance of presenting flexible flat foot during late childhood, adolescence and adulthood, a fact that suggests a relationship between these two pathologies. Also, patients who seek assistance for the first time because of a flexible flat foot condition without having been evaluated during the first year of life for hip dysplasia, would be better off if evaluated for residual hip dysplasia. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  1. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

    Directory of Open Access Journals (Sweden)

    Nussbaumer Silvio

    2010-08-01

    Full Text Available Abstract Background The aims of this study were to evaluate the construct validity (known group, concurrent validity (criterion based and test-retest (intra-rater reliability of manual goniometers to measure passive hip range of motion (ROM in femoroacetabular impingement patients and healthy controls. Methods Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study. Results The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; P P Conclusions The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.

  2. The Influence of Body Mass Index, Sex, & Muscle Activation on Pressure Distribution During Lateral Falls on the Hip.

    Science.gov (United States)

    Pretty, Steven P; Martel, Daniel R; Laing, Andrew C

    2017-12-01

    Hip fracture incidence rates are influenced by body mass index (BMI) and sex, likely through mechanistic pathways that influence dynamics of the pelvis-femur system during fall-related impacts. The goal of this study was to extend our understanding of these impact dynamics by investigating the effects of BMI, sex, and local muscle activation on pressure distribution over the hip region during lateral impacts. Twenty participants underwent "pelvis-release experiments" (which simulate a lateral fall onto the hip), including muscle-'relaxed' and 'contracted' trials. Males and low-BMI individuals exhibited 44 and 55% greater peak pressure, as well as 66 and 56% lower peripheral hip force, compared to females and high-BMI individuals, respectively. Local muscle activation increased peak force by 10%, contact area by 17%, and peripheral hip force by 11% compared to relaxed trials. In summary, males and low-BMI individuals exhibited more concentrated loading over the greater trochanter. Muscle activation increased peak force, but this force was distributed over a larger area, preventing increased localized loading over the greater trochanter. These findings suggest potential value in incorporating sex, gender, and muscle activation-specific force distributions as inputs into computational tissue-level models, and have implications for the design of personalized protective devices including wearable hip protectors.

  3. Second hip fractures at Chiang Mai University Hospital.

    Science.gov (United States)

    Wongtriratanachai, Prasit; Chiewchantanakit, Siripong; Vaseenon, Tanawat; Rojanasthien, Sattaya; Leerapun, Taninnit

    2015-02-01

    Hip fractures are a major public health problem. Patients who have suffered a hip fracture have an increased risk of a subsequent hip fracture. This study examines the incidence ofsecondhip fractures and attempts to identify underlying risk factors. To examine the incidence ofsecond hip fractures in osteoporotic patients at Chiang Mai University Hospital and to identify risk factors related to second hip fractures. A retrospective review was conducted of all low-energy mechanism hip fracture patients admitted during 2008 and 2009. Analysis of second hip fractures was conducted using survival analysis and logistic regression analysis. A total of 191 patients were observed for 391.68 person-years (mean 2.05 person-years per patient). Among that group, nine second hip fractures were identified, an overall incidence rate of 0.023 second fractures per person-year. Second hip fractures tended to occur within the first year following an initial hip fracture. There were no significant differences related to either gender or comorbid medical conditions. Logistic regression analysis revealed that increased risk of a second hip fracture was associated with age (highest between 80 to 89 years) and patients who were not treated for osteoporosis following their initial fracture. The incidence of second hip fractures at Chiang Mai University Hospital was 0.023 per person-year Careful follow-up of older patients, especially those over 80, and treatment ofosteoporosis with bisphosphonate plus vitamin D and calcium supplements was correlated with a reduction in the incidence of second hip fractures.

  4. Ultrasonography of the pediatric hip and spine

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yeo Ryang; Koo, Joon Bun [Dept. of Radiology, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies.

  5. Anatomic and radiographic evaluation of the hip

    Energy Technology Data Exchange (ETDEWEB)

    Llopis, Eva, E-mail: evallopis@gmail.com [Hospital de la Ribera, Carretera de Corbera km1, Alzira 46600, Valencia (Spain); Higueras, Victoria; Vaño, Maria [Hospital de la Ribera, Carretera de Corbera km1, Alzira 46600, Valencia (Spain); Altónaga, José R. [Leon University, 24071 Leon (Spain)

    2012-12-15

    The hip is a challenging joint to study is deeply located in the pelvis and surrounding by a large group of muscles with complex tendinous attachments. Our knowledge has recently increased together with the advent of new surgical techniques but further research is needed to better understand hip biomechanics and the relevance of some of radiological findings. Although recent techniques such as MR show anatomy exquisitely is essential to start with pelvis plain radiography for a good evaluation of bone structures and pelvis alignment. During this chapter we will be give a short overview of pelvis normal structures and some key points of MR and MR arthrography technique, because more detailed description is done on every specific chapter.

  6. Biomimetic Composite-Metal Hip Resurfacing Implant

    Directory of Open Access Journals (Sweden)

    Habiba Bougherara

    2008-01-01

    Full Text Available Hip resurfacing technique is a conservative arthroplasty used in the young patient in which the femoral head is reshaped to accept metal cap with small guide stem. In the present investigation, a hybrid composite-metal resurfacing implant is proposed. The cup is made of carbon fiber/polyamide 12 (CF/PA12 covered with a thin layer of cobalt chrome (Co-Cr. Finite element (FE method was applied to analyze and compare the biomechanical performances of the hybrid hip resurfacing (HHR and the conventional Birmingham (BHR. Results of the finite element analysis showed that the composite implant leads to an increase in stresses in the cancellous bone by more than 15% than BHR, indicating a lower potential for stress shielding and bone fracture and higher potential for bone apposition with the HHR.

  7. Arthrography of the hip in children

    International Nuclear Information System (INIS)

    Loennerholm, T.

    1980-01-01

    A method by which bilateral hip arthrography was performed under general anaesthesia in 130 infants and children 1 month to 7 years of age is described. Significant contractures of the adductor muscles had been corrected before the examination. Most of the children were girls with unilateral congenital idiopathic hip instability detected before the age of one year. From films exposed in standardized projections valuable information was obtained about the configuration of the joint cavity and the size and shape of the femoral head. Criteria for normal appearance in infants of ages 2 to 12 months are presented. More reliable details on the relation between the articular surfaces, the radiographic anatomy of the acetabulum and the distribution of the contrast medium were yielded by stereoradiography. Closed reduction was usually accomplished successfully during the arthrography, which made beginning of definitive treatment under the same anaesthesia possible. (Auth.)

  8. Fast-track hip and knee arthroplasty

    DEFF Research Database (Denmark)

    Husted, Henrik

    2012-01-01

    Fast-track hip and knee arthroplasty aims at giving the patients the best available treatment at all times, being a dynamic entity. Fast-track combines evidence-based, clinical features with organizational optimization including a revision of traditions resulting in a streamlined pathway from...... on clinical and organizational aspects of fast-track hip and knee arthroplasty (I–IX). A detailed description of the fast-track set-up and its components is provided. Major results include identification of patient characteristics to predict length of stay and satisfaction with different aspects...... of the hospital stay (I); how to optimize analgesia by using a compression bandage in total knee arthroplasty (II); the clinical and organizational set-up facilitating or acting as barriers for early discharge (III); safety aspects following fast-track in the form of few readmissions in general (IV) and few...

  9. Ultrasonography of the pediatric hip and spine

    International Nuclear Information System (INIS)

    Kang, Yeo Ryang; Koo, Joon Bun

    2017-01-01

    Ultrasonography (US) is a useful screening method for the diagnosis of developmental dysplasia of the hip (DDH) and congenital spinal anomalies in infants. In addition, US is a useful, noninvasive imaging modality for the diagnosis of transient synovitis in children. The early detection of DDH leads to a better prognosis without surgical intervention. Moreover, spinal US allows the detection of congenital malformations and can also demonstrate normal anatomy and normal variants that may resemble disorders. Therefore, radiologists should be familiar with the sonographic anatomy of the normal infant hip, scanning and measurement techniques for DDH, the US features of transient synovitis in children, spinal US techniques, and the US features of normal anatomical structures, normal variants, and congenital spinal anomalies

  10. Influence of bone mineral density and hip geometry on the different types of hip fracture.

    Science.gov (United States)

    Li, Yizhong; Lin, Jinkuang; Cai, Siqing; Yan, Lisheng; Pan, Yuancheng; Yao, Xuedong; Zhuang, Huafeng; Wang, Peiwen; Zeng, Yanjun

    2016-01-01

    The aim of this study was to assess the influence of bone mineral density and hip geometry on the fragility fracture of femoral neck and trochanteric region. There were 95 menopausal females of age ≥ 50 years with fragility fracture of hip, including 55 cases of femoral neck fracture and 40 cases of trochanteric fracture. Another 63 non-fractured females with normal bone mineral density (BMD) were chosen as control. BMD, hip axis length, neck-shaft angle and structural parameters including cross surface area, cortical thickness and buckling ratio were detected and compared. Compared with control group, the patients with femoral neck fracture or trochanteric fractures had significantly lower BMD of femoral neck, as well as lower cross surface area and cortical thickness and higher buckling ratio in femoral neck and trochanteric region. There were no significant differences of BMD and structural parameters in the femoral neck fracture group and intertrochanteric fracture group. Hip axis length and neck-shaft angle were not significantly different among three groups. The significant changes of BMD and proximal femur geometry were present in the fragility fracture of femoral neck and trochanteric region. The different types of hip fractures cannot be explained by these changes.

  11. Influence of bone mineral density and hip geometry on the different types of hip fracture

    Directory of Open Access Journals (Sweden)

    Yizhong Li

    2016-01-01

    Full Text Available The aim of this study was to assess the influence of bone mineral density and hip geometry on the fragility fracture of femoral neck and trochanteric region. There were 95 menopausal females of age ≥ 50 years with fragility fracture of hip, including 55 cases of femoral neck fracture and 40 cases of trochanteric fracture. Another 63 non-fractured females with normal bone mineral density (BMD were chosen as control. BMD, hip axis length, neck-shaft angle and structural parameters including cross surface area, cortical thickness and buckling ratio were detected and compared. Compared with control group, the patients with femoral neck fracture or trochanteric fractures had significantly lower BMD of femoral neck, as well as lower cross surface area and cortical thickness and higher buckling ratio in femoral neck and trochanteric region. There were no significant differences of BMD and structural parameters in the femoral neck fracture group and intertrochanteric fracture group. Hip axis length and neck-shaft angle were not significantly different among three groups. The significant changes of BMD and proximal femur geometry were present in the fragility fracture of femoral neck and trochanteric region. The different types of hip fractures cannot be explained by these changes.

  12. Arthrodiastasis for stiff hips in young patients

    OpenAIRE

    Cañadell, J.M. (J. M.); Gonzales, F. (F.); Barrios, R.H. (Raúl H.); Amillo, S. (Santiago)

    1993-01-01

    Joint distraction (arthrodiastasis) with a unilateral fixator was used to treat 9 patients with stiffness of the hip which had followed Perthes' disease (3), epiphysiolysis (2), congenital dysplasia (2), tuberculosis (1) and idiopathic chondrolysis (1). Their average age was 14 years, and they all had pain, limp and shortening of the leg. Distraction of 0.5 to 1 cm was maintained for an average of 94 days. The average range of movement subsequently was 65 degrees compared with 20 degrees befo...

  13. Complications of hip fractures: A review

    OpenAIRE

    Carpintero, Pedro; Caeiro, Jose Ramón; Carpintero, Rocío; Morales, Angela; Silva, Samuel; Mesa, Manuel

    2014-01-01

    Nowadays, fracture surgery represents a big part of the orthopedic surgeon workload, and usually has associated major clinical and social cost implications. These fractures have several complications. Some of these are medical, and other related to the surgical treatment itself. Medical complications may affect around 20% of patients with hip fracture. Cognitive and neurological alterations, cardiopulmonary affections (alone or combined), venous thromboembolism, gastrointestinal tract bleedin...

  14. Endotoxins in surgical instruments of hip arthroplasty

    OpenAIRE

    Goveia, Vania Regina; Mendoza, Isabel Yovana Quispe; Guimarães, Gilberto Lima; Ercole, Flavia Falci; Couto, Bráulio Roberto Gonçalves Marinho; Leite, Edna Marilea Meireles; Stoianoff, Maria Aparecida Resende; Ferreira, José Antonio Guimarães

    2016-01-01

    Abstract OBJECTIVE To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. METHOD A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60...

  15. Uudised : Pop-karneval. Hip-hop

    Index Scriptorium Estoniae

    2005-01-01

    Muusika- ja kunstikarnevalist "Beta Bubble" 1. apr. Tallinnas Von Krahlis. Pärnu taasühinenud hip-hop-bänd Noizmakaz (TommyBoy ja Alko) sõlmis lepingu plaadifirmaga Mindnote ja annab selle alt apr. keskel välja oma teise albumi "Valitud mõtted".1. apr. tuleb müügile Noizmakazi singel "Miski muu ei loe", debüüt "Social Poetry" ilmus aastal 2001

  16. Traction-related problems after hip arthroscopy

    Science.gov (United States)

    Lund, Bent; Grønbech Nielsen, Torsten; Lind, Martin

    2017-01-01

    Abstract Traction-related problems are poorly described in the existing literature. The purpose of this prospective study was to describe traction-related problems and how patients perceive these problems. The study was a descriptive cohort study and data were collected from questionnaires and patient files. The questionnaire included questions on patients’ perceptions of traction-related problems in the groin area, at the knee and ankle and how patients had coped with these problems. A total of 100 consecutive patients undergoing hip arthroscopy filled out the questionnaire. Primary findings of this study were that 74% of patients reported some sort of traction-related problems after hip arthroscopy. About 32% of the patients had problems in the groin area and 49% of the patients complained of symptoms in the knee joint. A total of 37% of the patients had experienced problems from the traction boot in the ankle area. The complications were found to be temporary and disappeared after 2–4 weeks. Five patients still had complaints after 3 months. All five patients had a pre-existing knee injury prior to undergoing hip arthroscopy. Traction-related problems after hip arthroscopy are a challenge and our study showed that 74% of the patients reported traction-related problems. This is significantly higher than previously reported. The present study found a high rate of complaints from the knee and ankle joints that have not previously been reported. The presented data suggest the need for more pre-surgery patient information about possible traction-related problems. PMID:28630721

  17. The anatomy of the hip abductor muscles.

    Science.gov (United States)

    Flack, N A M S; Nicholson, H D; Woodley, S J

    2014-03-01

    The anatomy of the hip abductors has not been comprehensively examined, yet is important to understanding function and pathology in the gluteal region. For example, pathology of the hip abductor muscle-tendon complexes can cause greater trochanteric pain syndrome, and may be associated with gluteal atrophy and fatty infiltration. The purpose of this study was to investigate the detailed morphology of gluteus medius (GMed), gluteus minimus (GMin), and tensor fascia lata (TFL), and determine whether the muscles comprised anatomical compartments. The gluteal region from 12 cadavers was dissected and data collected on attachment sites, volume, fascicular and tendinous anatomy, and innervation. Three sites of GMed origin were identified (gluteal fossa, gluteal aponeurosis, and posteroinferior edge of the iliac crest) and the distal tendon had lateral and posterior parts. GMed was the largest in volume (27.6 ± 11.6 cm(3); GMin 14.1 ± 11.1 cm(3); TFL 1.8 ± 0.8 cm(3)). Fascicles of GMin originated from the gluteal fossa, inserting onto the deep surface of its distal tendon and the hip joint capsule. TFL was encapsulated in the fascia lata, having no bony attachment. Primary innervation patterns varied for GMed, with three or four branches supplying different regions of muscle. Distinct secondary nerve branches entered four regions of GMin; no differential innervation was observed for TFL. On the basis of architectural parameters and innervation, GMed, and GMin each comprise of four compartments but TFL is a homogenous muscle. It is anticipated that these data will be useful for future clinical and functional studies of the hip abductors. Copyright © 2013 Wiley Periodicals, Inc.

  18. Rapidly Destructive Inflammatory Arthritis of the Hip

    Directory of Open Access Journals (Sweden)

    Jenny Shu

    2014-01-01

    Full Text Available Rapidly destructive coxarthrosis (RDC is a rare syndrome that involves aggressive hip joint destruction within 6–12 months of symptom onset with no single diagnostic laboratory, pathological, or radiographic finding. We report an original case of RDC as an initial presentation of seronegative rheumatoid arthritis (RA in a 57-year-old Caucasian woman presenting with 6 months of progressive right groin pain and no preceding trauma or chronic steroid use. Over 5 months, she was unable to ambulate and plain films showed complete resorption of the right femoral head and erosion of the acetabulum. There were inflammatory features seen on computed tomography (CT and magnetic resonance imaging (MRI. She required a right total hip arthroplasty, but arthritis in other joints showed improvement with triple disease modifying antirheumatic drugs (DMARD therapy and almost complete remission with the addition of adalimumab. We contrast our case of RDC as an initial presentation of RA to 8 RDC case reports of patients with established RA. Furthermore, this case highlights the importance of obtaining serial imaging to evaluate a patient with persistent hip symptoms and rapid functional deterioration.

  19. Congenital hip dislocation: Radiological screening or diagnosis?

    International Nuclear Information System (INIS)

    Kalifa, G.; Faure, C.

    1987-01-01

    Congenital hip dislocation is a perfect example of public health problems: its incidence is high 0.6, to 2% of newborns in France and an early detection allows an easy and successful treatment. The current situation in our country is not satisfactory for several reasons: - Too many children are treated without reasons because of misleading radiological pictures; - Conversely, some dislocations are discovered only at the walking age, the treatment becoming then more difficult and less effective; - Almost 300,000 radiological examinations of the hip for screening are performed each year and among them 100,000 in newborns. This is not satisfactory as it is commonly admitted now that radiological examination at birth is unreliable and frequently misleading. For all these reasons a special working group has been settled up by the General Direction of Health, including physicians of different practices, from different specialities. The conclusion of this group will be published in a special booklet and can be summarized as follows: The group recommends to perform detection of congenital hip dislocation mainly by the clinical examination. This examination may be difficult but it must be performed very early, the first day of life, repeated several times, at the end of the first week and during the first, second, and third month. Every baby in this country must undergo several clinical examinations up to one year of age

  20. Imaging of neuropathies about the hip

    Energy Technology Data Exchange (ETDEWEB)

    Martinoli, Carlo, E-mail: carlo.martinoli@unige.it [Radiologia – DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Miguel-Perez, Maribel [Unit of Human Anatomy and Embryology, Department of Pathology and Experimental Therapy, Faculty of Medicine (C Bellvitge), University of Barcelona, Barcelona (Spain); Padua, Luca [Fondazione Don Gnocchi Onlus and Department of Neurology, Policlinico “A. Gemelli”, Università Cattolica del Sacro Cuore, Rome (Italy); Gandolfo, Nicola [IM2S – Institut Monégasque de Médecine and Chirurgie Sportive, Montecarlo (Monaco); Zicca, Anna [Radiologia – DISC, Università di Genova, Largo Rosanna Benzi 8, I-16132 Genoa (Italy); Tagliafico, Alberto [Radiologia – National Institute for Cancer Research, Genoa (Italy)

    2013-01-15

    Neuropathies about the hip may be cause of chronic pain and disability. In most cases, these conditions derive from mechanical or dynamic compression of a segment of a nerve within a narrow osteofibrous tunnel, an opening in a fibrous structure, or a passageway close to a ligament or a muscle. Although the evaluation of nerve disorders primarily relies on neurological examination and electrophysiology, diagnostic imaging is currently used as a complement to help define the site and aetiology of nerve compression and exclude other disease possibly underlying the patient’ symptoms. Diagnosis of entrapment neuropathies about the hip with US and MR imaging requires an in-depth knowledge of the normal imaging anatomy and awareness of the anatomic and pathologic factors that may predispose or cause a nerve injury. Accordingly, the aim of this article is to provide a comprehensive review of hip neuropathies with an emphasis on the relevant anatomy, aetiology, clinical presentation, and their imaging appearance. The lateral femoral cutaneous neuropathy (meiralgia paresthetica), femoral neuropathy, sciatic neuropathy, obturator neuropathy, superior and inferior gluteal neuropathies and pudendal neuropathy will be discussed.

  1. RELIABILITY AND VALIDITY OF CLINICAL AND ULTRASOUND EXAMINATIONS OF DEVELOPMENTAL HIP DYSPLASIA

    Directory of Open Access Journals (Sweden)

    Predrag Grubor

    2011-03-01

    Full Text Available Developmental dysplasia of the hip (DDH is the most common congenital deformation of the musculoskeletal system and its successful treatment is closely related to early diagnosis. The study is aimed at examining the incidence of developmental dysplasia of the hip (DDH and at analysing the validity of clinical examination, which is used for the early detection of DDH in the neonatal period, compared to ultrasound examination.The study involved 400 neonates born in the Banja Luka Region. A new questionnaire was open during the first regular ultrasound and clinical examination of the neonates’ hips and anamnestic and clinical data were recorded in it: the asymmetry of the gluteal, inguinal and femoral folds (Bade sign, the result of abduction testseparately for each hip, the Ortolani sign of luxation and the Palmen sign of reposition, then hip sonography. A Toshiba ultrasound machine with a 7.5 MHz linear probe was used. The method employed was Professor Reinhard Graf’s. Out of the total number of the children with a positive sonographic finding for DDH, 63.16% of them have one of the clinical signs of DDH. The ability of a clinical finding to identify those patients who do not have DDH and have a negative sonographic finding is 79.8%. Out of the total number of the examined children with a positive clinical finding, only 15.58% of them also have a positive sonographic finding for DDH. This research has showed that clinical examination of the hips is of low sensitivity, specificity and reliability, and that not all types of DDH can be detected. Clinical examination must remain an integral part of every infant’s examination, but it constitutes a complementary diagnostic procedure to ultrasound examination. The ultrasound examination of DDH has created new possibilities and has filled the void that existed due to the deficiency of clinical tests, and at the same time it has reduced the number of X-ray examinations of the hips. This research has

  2. Hip fracture prevention with a multifactorial educational program in elderly community-dwelling Finnish women.

    Science.gov (United States)

    Pekkarinen, T; Löyttyniemi, E; Välimäki, M

    2013-12-01

    Guidelines suggest identification of women at fracture risk by bone density measurement and subsequently pharmacotherapy. However, most women who sustain a hip fracture do not have osteoporosis in terms of bone density. The present non-pharmacological intervention among elderly women unselected for osteoporosis reduced hip fracture risk by 55 % providing an alternative approach to fracture prevention. Hip fractures are expensive for society and cause disability for those who sustain them. We studied whether a multifactorial non-pharmacological prevention program reduces hip fracture risk in elderly women. A controlled trial concerning 60- to 70-year-old community-dwelling Finnish women was undertaken. A random sample was drawn from the Population Information System and assigned into the intervention group (IG) and control group (CG). Of the 2,547 women who were invited to the IG, 1,004 (39 %) and of the 2,120 invited to the CG, 1,174 (55 %) participated. The IG participated in a fracture prevention program for 1 week at a rehabilitation center followed by review days twice. The CG received no intervention. During the 10-year follow-up, both groups participated in survey questionnaire by mail. Outcome of interest was occurrence of hip fractures and changes in bone-health-related lifestyle. During the follow-up, 12 (1.2 %) women in the IG and 29 (2.5 %) in the CG sustained a hip fracture (P = 0.039). The determinants of hip fractures by stepwise logistic regression were baseline smoking (odds ratio (OR) 4.32 (95 % confidence interval [CI] 2.14-8.71), age OR 1.15/year (95 % CI 1.03-1.28), fall history OR 2.7 (95 % CI 1.24-5.9), stroke history OR 2.99 (95 % CI 1.19-7.54) and participating in this program OR 0.45 (95 % CI 0.22-0.93). Starting vitamin D and calcium supplement use was more common in the IG compared with the CG. The results suggest that this non-pharmacological fracture prevention program may reduce the risk of hip fractures in elderly

  3. Hip orthosis powered by pneumatic artificial muscle: voluntary activation in absence of myoelectrical signal.

    Science.gov (United States)

    do Nascimento, Breno Gontijo; Vimieiro, Claysson Bruno Santos; Nagem, Danilo Alves Pinto; Pinotti, Marcos

    2008-04-01

    Powered orthosis is a special class of gait assist device that employs a mechanical or electromechanical actuator to enhance movement of hip, knee, or ankle articulations. Pneumatic artificial muscle (PAM) has been suggested as a pneumatic actuator because its performance is similar to biological muscle. The electromyography (EMG) signal interpretation is the most popular and simplest method to establish the patient voluntary control of the orthosis. However, this technique is not suitable for patients presenting neurological lesions causing absence or very low quality of EMG signal. For those cases, an alternative control strategy should be provided. The aim of the present study is to develop a gait assistance orthosis for lower limb powered by PAMs controlled by a voluntary activation method based on the angular behavior of hip joint. In the present study, an orthosis that has been molded in a patient was employed and, by taking her anthropometric parameters and movement constraints, the adaptation of the existing orthosis to the powered orthosis was planned. A control system was devised allowing voluntary control of a powered orthosis suitable for patients presenting neurological lesions causing absence or very low quality of EMG signal. A pilot clinical study was reported where a patient, victim of poliovirus, successfully tested a hip orthosis especially modified for the gait test evaluation in the parallel bar system. The hip orthosis design and the control circuitry parameters were able to be set to provide satisfactory and comfortable use of the orthosis during the gait cycle.

  4. Rethinking Pedagogy in Urban Spaces: Implementing Hip-Hop Pedagogy in the Urban Science Classroom

    Science.gov (United States)

    Adjapong, Edmund S.; Emdin, Christopher

    2015-01-01

    A significant amount of research regarding Hip-Hop Based Education (HHBE) fails to provide insight on how to incorporate elements of Hip-Hop into daily teaching practices; rather Hip-Hop based educators focus mainly on incorporating Hip-Hop culture into curricula. This study explores the benefits of using two specific Hip-Hop pedagogical practices…

  5. "Tripolar" hip arthroplasty for failed hip resurfacing: nineteen years follow-up.

    Science.gov (United States)

    Scheerlinck, T; Casteleyn, P P

    2001-10-01

    The authors describe the case of a 37-year-old patient who sustained a subcapital femoral neck fracture six months after ICLH double-cup hip resurfacing. As the polyethylene acetabular resurfacing component was undamaged and well fixed, a standard femoral stem with a bipolar head was inserted. The outer diameter of the bipolar head was chosen to fit the resurfacing socket. The "tripolar" hip arthroplasty has functioned well for 19 years and was revised for aseptic cup loosening. The cemented femoral stem was still well fixed and was not revised. Although the "tripolar" hip has functioned well in our case, we believe it is not indicated for metal on metal bearings. In this case the use of an appropriate modular head with a correct head-socket clearance is preferred.

  6. The relationship of hip joint space to self reported hip pain

    DEFF Research Database (Denmark)

    Jacobsen, S.; Holm, S.S.; Lund, B.

    2004-01-01

    OBJECTIVES: (1) To evaluate the effect of pelvic orientation on measurements of hip joint space widths (JSW) in cadaver pelvic radiographs, thereby validating the pelvic radiographs of the Copenhagen City Heart Study: The Osteoarthritis Substudy (CCHS III) cohort of 4.152 subjects, and (2......) to investigate the relationship between minimal JSW and self reported hip pain of the cohort. METHODS: (1) Cadaver pelves and proximal femora of one male and one female donor were mounted in holding devices permitting independent rotation (total arc of 42 degrees), and inclination/reclination (total arc of 24...... degrees). At each 3 degrees increment an anteroposterior radiograph was recorded. Measurements of JSW were performed. (2) Self reported recurrent pain in or around the hip joint during 12 months prior to baseline examinations, and minimum JSW in pelvic radiographs of the cohort were registered...

  7. Bone remodelling of the proximal femur after total hip arthroplasty with 2 different hip implant designs

    DEFF Research Database (Denmark)

    Christiansen, Janus D.; Laursen, Mogens B; Ejaz, Ashir

    2018-01-01

    INTRODUCTION: The thrust plate prosthesis (TPP) was introduced to preserve bone in patients undergoing total hip arthroplasty. We assessed the long-term results of hip arthroplasty in patients who received the TPP compared to a traditional intramedullary stem (Bi-Metric). METHODS......: In this prospective observational cohort study, we evaluated bone mineral density (BMD) using dual-energy X-ray absorptiometry (DXA), radiological imaging and clinical outcome using Harris Hip Score (HHS). Twenty patients received the TPP (group A) and 18 patients received the Bi-Metric stem (group B). Baseline......% (95% confidence interval [CI], 4-16; p = 0.003) and 8% (95% CI, 1-15; p = 0.03) at 8 years. Regarding ROI4, group A had a lesser decrease in general compared to group B. The radiological findings did not reveal any subsidence or detectable implant migration. HHS improved from 53 (23-69) to 93 (55...

  8. Clinical and radiological evaluation of hybrid hip replacement in various disorders of hip

    Directory of Open Access Journals (Sweden)

    Dhaon B

    2005-01-01

    Full Text Available Background: High rates of loosening of cemented implants led to change in technique of fixation of the implant. Methods: Fifty-nine hips were operated in 42 patients with non-cemented acetabular and cemented femoral components between January 1999 and July 2003. The average age of the patient was 45.2 years in our study. Preoperative diagnosis was avascular necrosis (28, ankylosing spondylitis (18, fracture neck femur (9, rheumatoid arthritis (2 and osteoarthritis (2. Results: At an average follow up of 3.6 years (range 1.2-5.8 years excellent to good results were obtained 92% according to Harris hip criteria. No radiological loosening was noted in any femoral or acetabular component on follow up. One poor result was seen in a case of bilateral ankylosing spondylitis operated on one side. Conclusion: Hybrid THA provides a viable and highly acceptable method of treatment of diseases of hip in young patients.

  9. HIP FRACTURES IN THE ELDERLY PATIENT

    Directory of Open Access Journals (Sweden)

    Franci Koglot

    2001-11-01

    Full Text Available Background. Hip fractures are typical of the ageingpopulation. They represent a severe trauma for the elderlypatient due to significant impact on life quality and morbidity.We analyzed the characteristics of patients with hip fractures,the methods and success of treatment. In conclusion, theimportance of continuous team approach and surgical treatmentwithin 24 hours are stressed. Methods. We retrospectively evaluated patients admitted forfemoral neck and intertrochanteric fractures between 1994–1999. The incidence of these fractures, patient age and sex, comorbidity,methods of treatment, hospital stay and success oftreatment with regard to ambulatory status were established.Results. 662 patients were treated in the above mentioned period,yielding a 1‰ annual incidence for the choosen population.The mean patient age was 76 years; there were 426 female(64% and 236 male patients (36%. 336 patients (51%had a history of accompanying disease, in 73 patients (11%additional fractures were diagnosed. 30 patients (4.5% weretreated conservatively, 632 (95.5% underwent surgery. Themean hospital stay length was 17 days. Success of treatmentwas evaluated as good in 441 patients (67%, satisfactory in112 patients (17% and poor in 78 patients (12%. 31 patients(5% died during hospital admission. Conclusions. Patients with hip fractures represent 10% of allin-hospital trauma patients; with hospital stays twice as longas average trauma patients and considering the financial demandsof surgical treatment they are a challenge in traumawards organization and management in the Slovenian environment.Here as well as abroad the number of these patientsis increasing, along with their mean age and co-morbidity. Itis evident that hip fractures, regardless the way of treatment,implicate a partial or complete loss of ambulancy and henceloss of life-quality in one-third of patients. We advise early aspossible surgery –within 24 h– where not absolutely

  10. Evolution of the human hip. Part 1: the osseous framework.

    Science.gov (United States)

    Hogervorst, Tom; Vereecke, Evie E

    2014-10-01

    Extensive osseous adaptations of the lumbar spine, pelvis, hip and femur characterize the emergence of the human bipedal gait with its 'double extension' of the lumbar spine and hip. To accommodate lumbar lordosis, the pelvis was 'compacted', becoming wider and shorter, as compared with the non-human apes. The hip joint acquired a much more extended position, which can be seen in a broader evolutionary context of verticalization of limbs. When loaded in a predominantly vertical position, the femur can be built lighter and longer than when it is loaded more horizontally because bending moments are smaller. Extension of the hip joint together with elongation of the femur increases effective leg length, and hence stride length, which improves energy efficiency. At the hip joint itself, the shift of the hip's default working range to a more extended position influences concavity at the head-neck junction and femoral neck anteversion.

  11. Design of biped hip simulator using SolidWorks

    Science.gov (United States)

    Zainudin, M. R.; Yahya, A.; Fazli, M. I. M.; Syahrom, A.; Harun, F. K. C.; Nazarudin, M. S.

    2017-10-01

    The increasing number of people who underwent both hip implant surgery based on World Health Organization (WHO) has received massive attention from researchers lately to develop various types of hip simulators in order to test the hip implant. Various number of hip simulator have been developed with different functions and capabilities. This paper presents the design development of biped hip simulator using SolidWorks software by taking into consideration some improvement and modifications. The finite element method is used to test the design whether it is safe to be used or not. The biped hip simulator has been successfully designed and ready to be fabricated as the endurance testing shown a positive results. The von Mises stress induced in the material is an alloy steel which is 2,975,862.3 N/m2 lower than the yield strength. Thus, the design is safe to be used as it obey the safety criterion.

  12. Perceived loading and muscle activity during hip strengthening exercises

    DEFF Research Database (Denmark)

    Brandt, Mikkel; Jakobsen, Markus Due; Thorborg, Kristian

    2013-01-01

    hip muscle activity during hip abduction and hip adduction exercises using elastic resistance and isotonic machines, using electromyography (EMG). METHODS: EMG activity was recorded from 11 muscles at the hip, thigh and trunk during hip adduction and hip abduction exercises in 16 untrained women......, using elastic resistance and isotonic exercise machines. These recordings were normalized to maximal voluntary contraction (MVC) EMG (nEMG). The exercises were performed at four levels of perceived loading reported using the Borg CR10: light (Borg ≤2), moderate (Borg >2-... (r =0.62±0.54). The abduction exercise performed with elastic resistance displayed significantly higher gluteus medius nEMG recruitment than the in machine exercise. CONCLUSIONS: The results of this study show that the Borg CR10 scale can be a useful tool for estimating intensity levels during...

  13. Arthroscopy of the Nondistractable Hip: A Novel Extracapsular Approach

    Science.gov (United States)

    Doron, Ran; Amar, Eyal; Rath, Ehud; Sampson, Thomas; Ochiai, Derek; Matsuda, Dean K.

    2014-01-01

    Adequate traction to achieve hip joint distraction is essential for avoiding iatrogenic injury to the joint during hip arthroscopy. An inability to distract the joint is a relative contraindication for hip arthroscopy. This report describes a novel technique involving an extracapsular approach to gain safe access to a hip joint that fails a trial of traction during positioning for hip arthroscopy. The anterolateral portal is established under fluoroscopic guidance. The arthroscope is positioned on the lateral rim of the acetabulum. A shaver, introduced through a modified anterior portal, is used to facilitate capsular exposure. An arthroscopic capsular incision is made proximal to the lateral acetabular rim and extended anteriorly with a radiofrequency probe. Osteoplasty of the anterolateral acetabular rim is carried out with a burr while protecting the labrum. Distraction of the hip is then possible, allowing safe central-compartment access and subsequent chondrolabral procedures. PMID:25685682

  14. Late total hip arthroplasty dislocation due to yoga

    Directory of Open Access Journals (Sweden)

    Murillo Adrados, MD

    2018-06-01

    Full Text Available Yoga has become a popular form of exercise, recreation, and meditation for adults in the United States. As the popularity of both yoga and the incidence of hip replacements have both coincidentally increased over the last 2 decades, we imagine that the number of total hip replacement patients partaking in the practice of yoga has also increased. There are no clear guidelines available for yoga practice following hip replacement. To date, there have been no published reports of prosthetic hip dislocations during yoga. We present 2 cases of late total hip dislocations during yoga and provide a review of the available orthopaedic literature and our recommendations on patient restrictions and education with respect to practicing yoga after a hip replacement.

  15. Anterior Hip Dislocation in a Football Player: A Case Report

    Directory of Open Access Journals (Sweden)

    Alexander Schuh

    2009-01-01

    Full Text Available Hip dislocations during sporting activities represent only 2%–5% of all hip dislocations. Most hip dislocations in sports can be categorised as “less complicated traumatic hip dislocations” by the Stewart-Milford classification due to the fact that minimal force is involved. The incidence of avascular necrosis of the femoral head greatly increases if the time to reduction is more than six hours. We report the case of a 38-year-old football player who suffered hip dislocation while kicking the ball with the medial aspect of the right foot in an external rotated manner of the right hip. Closed reduction was performed within 2 hours; postoperative follow-up was uneventful. Six months later the patient is out of any complaints; there is no sign of AVN of the femoral head.

  16. History and physical examination of hip injuries in elderly adults.

    Science.gov (United States)

    Hamedan Al Maqbali, Mohammed Abdullah

    2014-01-01

    Hip fracture is the most common injury occurring to elderly people and is associated with restrictions of the activities of the patients themselves. The discovery of a hip fracture can be the beginning of a complex journey of care, from initial diagnosis, through operational procedures to rehabilitation. The patient's history and physical examination form the basis of the diagnosis and monitoring of elderly patients with hip problems and dictate the appropriate treatment strategy to be implemented. The aim of this study is to discuss the different diagnoses of hip pain in a case study of an elderly woman who initially complained of pain in her right knee following a fall at home. It shows that musculoskeletal physical examination determined the management of the hip fracture that was found to be present. In addition, the aim of this article is to review diagnostic tests such as radiographs and recommend appropriate management and treatment of hip fractures in elderly patients.

  17. Successful staged hip replacement in septic hip osteoarthritis in osteopetrosis: a case report

    Directory of Open Access Journals (Sweden)

    Manzi Giovanni

    2012-04-01

    Full Text Available Abstract Background Osteopetrosis is a rare, inherited, bone disorder, characterized by osteosclerosis, obliteration of the medullary cavity and calcified cartilage. The autosomal dominant form is compatible with a normal life span, although fractures often result from minimal trauma, due to the pathologic nature of bone. Osteomyelitis is common in patients with osteopetrosis because of a reduced resistance to infection, attributed to the lack of marrow vascularity and impairment of white cell function. Only one case of osteomyelitis of the proximal third of the femur has been previously reported, treated with several repeated debridements and finally with femoral head resection. Here we present for the first time a case of a staged implant of a cementless total hip prosthesis for the treatment of a septic hip in femoral neck nonunion in osteopetrosis. Case presentation A 36-years-old woman, affected by autosomal dominant osteopetrosis was referred to our department because of a septic hip arthritis associated with femoral neck septic non-union, with draining fistulas. The infection occurred early after a plate osteosynthesis for a closed perthrocanteric fracture of the femur and persisted in spite of osteosynthesis removal, surgical debridement and external fixation. In our hospital the patient underwent accurate debridement, femoral head and greater trochanter resection, preparation of the diaphyseal intramedullary canal and implant of an antibiotic-loaded cement spacer. The spacer was exchanged after one month, due to infection recurrence and four months later, a cementless total hip arthroplasty was implanted, with no clinical and laboratory signs of infection recurrence at two years follow-up. Conclusions In case of hip septic arthritis and proximal femur septic non-union, femoral head resection may not be the only option available and staged total hip arthroplasty can be considered.

  18. Quality of life following hip fractures: results from the Norwegian hip fracture register.

    Science.gov (United States)

    Gjertsen, Jan-Erik; Baste, Valborg; Fevang, Jonas M; Furnes, Ove; Engesæter, Lars Birger

    2016-07-07

    Patient-reported health-related quality of life is an important outcome measure when assessing the quality of hip fracture surgery. The frequently used EQ-5D index score has unfortunately important limitations. One alternative can be to assess the distribution of each of the five dimensions of the patients' descriptive health profile. The objective of this paper was to investigate health-related quality of life (HRQoL) after hip fractures. Data from hip fracture operations from 2005 through 2012 were obtained from The Norwegian Hip Fracture Register. Patient reported HRQoL, (EQ-5D-3L) was collected from patients preoperatively and at four and twelve months postoperatively n = 10325. At each follow-up the distribution of the EQ-5D-3L and mean pain VAS was calculated. Generally, a higher proportion of patients reported problems in all 5 dimensions of the EQ-5D-3L at all follow-ups compared to preoperative. Also a high proportion of patients with no preoperative problems reported problems after surgery; At 4 and 12 months follow-ups 71 % and 58 % of the patients reported walking problems, and 65 % and 59 % of the patients reported pain respectively. Patients with femoral neck fractures and the youngest patients (age < 70 years) reported least problems both preoperatively and at all follow-ups. A hip fracture has a dramatic impact on the patients' HRQoL, and the deterioration in HRQoL sustained also one year after the fracture. Separate use of the descriptive profile of the EQ-5D is informative when assessing quality of life after hip fracture surgery.

  19. Psychological factors as risk factors for poor hip function after total hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Benditz A

    2017-02-01

    Full Text Available Achim Benditz,1 Petra Jansen,2 Jan Schaible,1 Christina Roll,1 Joachim Grifka,1 Jürgen Götz1 1Department of Orthopedics, University Medical Center Regensburg, Asklepios Klinikum Bad Abbach, Bad Abbach, 2Department of Sport Science, University of Regensburg, Regensburg, Germany Abstract: Recovery after total hip arthroplasty (THA is influenced by several psychological aspects, such as depression, anxiety, resilience, and personality traits. We hypothesized that preoperative depression impedes early functional outcome after THA (primary outcome measure. Additional objectives were perioperative changes in the psychological status and their influence on perioperative outcome. This observational study analyzed depression, anxiety, resilience, and personality traits in 50 patients after primary unilateral THA. Hip functionality was measured by means of the Harris Hip Score. Depression, state anxiety, and resilience were evaluated preoperatively as well as 1 and 5 weeks postoperatively. Trait anxiety and personality traits were measured once preoperatively. Patients with low depression and anxiety levels had significantly better outcomes with respect to early hip functionality. Resilience and personality traits did not relate to hip functionality. Depression and state anxiety levels significantly decreased within the 5-week stay in the acute and rehabilitation clinic, whereas resilience remained at the same level. Our study suggests that low depression and anxiety levels are positively related to early functionality after THA. Therefore, perioperative measurements of these factors seem to be useful to provide the best support for patients with risk factors. Keywords: total hip arthroplasty, psychological factors, depression, state anxiety, trait anxiety, resilience, personality traits

  20. Total hip arthroplasty using a short-stem prosthesis: restoration of hip anatomy.

    Science.gov (United States)

    Amenabar, Tomas; Marimuthu, Kanniraj; Hawdon, Gabrielle; Gildone, Alessandro; McMahon, Stephen

    2015-04-01

    To evaluate hip parameters such as vertical centre of rotation (VCR), horizontal centre of rotation (HCR), femoral offset, and leg length after total hip arthroplasty (THA) using the Nanos short-stem prosthesis. Medical records of 73 men and 74 women aged 25 to 92 (mean, 63) years who underwent THA using the Nanos short-stem prosthesis by a single surgeon were reviewed. Prior to the surgery, the optimal cup and stem size, head length, and level of the neck osteotomy were determined using radiographs. Intra-operatively, the leg length and femoral offset were checked, and the level of neck resection and head length were adjusted. VCR, HCR, femoral offset, and leg length of the operated and contralateral sides were compared. Functional outcomes were assessed using the Harris Hip Score (HHS). Compared with the normal contralateral hips, the operated hips had a mean increase of 0.4 mm in VCR (p=0.032), a mean decrease of 1.4 mm in HCR (p=0.027), a mean increase of 0.6 mm in femoral offset (p=0.043), and a mean increase of 0.36 mm in leg length (p=0.035). For these respective parameters, the difference between the normal contralateral side and the operated side was within 5 mm in 89%, 80%, 71%, and 96% of patients. The HHS improved from a mean of 53 to 91 at one year (pNanos short-stem prosthesis enabled restoration of hip anatomy (VCR, HCR, femoral offset, and leg length).

  1. Cementless Hip Stem Anteversion in the Dysplastic Hip: A Comparison of Tapered Wedge vs Metaphyseal Filling.

    Science.gov (United States)

    Taniguchi, Naofumi; Jinno, Tetsuya; Koga, Daisuke; Hagino, Tetsuo; Okawa, Atsushi; Haro, Hirotaka

    2017-05-01

    Appropriate stem anteversion is important for achieving stability of the prosthetic joint in total hip arthroplasty. Anteversion of a cementless femoral stem is affected by the femoral canal morphology and varies according to stem geometry. We investigated the difference and variation of the increase in anteversion between 2 types of cementless stems, and the correlation between each stem and the preoperative femoral anteversion. We retrospectively compared 2 groups of hips that underwent total hip arthroplasty using a metaphyseal filling stem (78 hips) or a tapered wedge stem (83 hips). All the patients had osteoarthritis due to hip dysplasia. Computed tomography was used to measure preoperative femoral anteversion at 5 levels and postoperative stem anteversion. The increase in anteversion of the tapered wedge stem group (22.7° ± 11.6°) was more than that of the metaphyseal filling stem group (17.2° ± 8.3°; P = .0007). The variation of the increase in the tapered wedge stem group was significantly larger than that in the metaphyseal filling stem group (P = .0016). The metaphyseal filling stem group was more highly and positively correlated with femoral anteversion than the tapered wedge stem group. Femoral anteversion affects stem anteversion differently according to stem geometry. The tapered wedge stems had greater variation of the increase in anteversion than did the metaphyseal filling stems. Based on the results of this study, it is difficult to preoperatively estimate the increase in stem anteversion for tapered wedge stems. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. The influence of heterotopic ossification on functional status of hip joint following total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Pohl, F.; Seufert, J.; Flentje, M.; Koelbl, O. [Wuerzburg Univ. (Germany). Dept. of Radiotherapy; Tauscher, A.; Springorum, H.W. [Caritas Krankenhaus Bad Mergentheim (Germany). Orthopedic Clinic; Lehmann, H. [Caritas Krankenhaus Bad Mergentheim (Germany). Inst. of Radiology

    2005-08-01

    Purpose: The functional failure induced by heterotopic ossification (HO) following total hip arthroplasty (THA) was analyzed and correlated to the radiologic failure. Patients and methods: From July 1997 to July 2001, 315 patients (345 hips) received THA indicated by a hypertrophic osteoarthritis of higher degree (Kellgren grade III, IV). All patients were irradiated prophylactically for prevention of HO on the evening before surgery with a 7-Gy single fraction. The patients' median age was 66.3 years. Radiologic failure was assessed by comparison of pre- and postoperative hip X-rays (immediately and 6 months after surgery). Analysis of radiographs was performed according to the Brooker Score. Clinical failure was appraised by measurement of passive range of motion (ROM) of the hip joint with a standard goniometer. The t-test was used for statistical analysis. Results: 281 patients (81.5%) did not develop HO. HO of Brooker grade I or II was found in 58 patients (16.8%). Six patients (1.7%) developed HO Brooker grade III or IV. There was a significant negative correlation between the degree of radiologic and clinical failure. ROM differed significantly between patients with HO Brooker grade 0, I, II and patients with HO Brooker grade III, IV. Comparing the pre- and postoperative ROM, all patients with Brooker grade 0, I and II showed a significant improvement of flexion, internal and external rotation, abduction and adduction movement. Patients with HO Brooker grade III and IV showed no improvement of ROM in the postoperative follow-up. Conclusion: The development of HO following THA influences the physical function of the hip joint dependent on the degree of ossification. HO of lower degree (Brooker I, II) does not influence the clinical outcome, whereas HO of higher degree (Brooker III, IV) reduces the function of hip arthroplasty. Therefore, the purpose of a prophylactic therapy must be to reduce HO of higher degree. (orig.)

  3. Rare Cause of Hip Pain: Transient Osteoporosis of the Hip-Two Case Reports

    Directory of Open Access Journals (Sweden)

    Senem Şaş

    2015-12-01

    Full Text Available Transient osteoporosis of the hip (TOH is a rare disease affecting especially middle-aged men and women in the third trimester of pregnancy with unknown etiology. It has a benign course with spontaneous resolution. Transient osteoporosis may be confused with other diseases such as avascular necrosis. Early diagnosis is important to identify and plan correct treatment. In this report, two male cases with complaint of hip pain and difficulty in walking, which were diagnosed with TOH was presented by reviewing current literature.

  4. X-Ray Hip Examination in Patients with Cerebral Palsy

    OpenAIRE

    Holiuk, Ye.L.

    2017-01-01

    Background. X-ray indicators of the hip are important diagnostic factors of spastic hip dislocation in cerebral palsy. Correct X-ray examination has a decisive influence on the treatment strategy. Correct positioning parameters are well known, but their importance is often underestimated. This could be a trigger factor for further diagnostic and treatment errors. Materials and me-thods. The material was radiographs of the hip joints of 126 patients with cerebral palsy aged 2 to 18 years. Retr...

  5. Healing incisional surgical wounds using Rose Hip oil in rats

    OpenAIRE

    Lainy Carollyne da Costa Cavalcante; Thyago Cezar Prado Pessôa; Rubens Fernando Gonçalves Ribeiro Júnior; Edson Yuzur Yasojima; Rosa Helena de Figueiredo Chaves Soares; Marcus Vinicius Henriques Brito; Eduardo Henrique Herbster Gouveia; Lucas Nascimento Galvão; Suzana Rodrigues Ramos; Adan Kristian Almeida Carneiro; Yuri Aarão Amaral Serruya; Mateus Malta de Moraes

    2017-01-01

    Purpose: To evaluate incisional surgical wound healing in rats by using Rose Hip (Rosa rubiginosa L.) oil. Methods: Twenty-one days after the oophorectomy procedure, twenty-seven female, adult, Wistar rats were distributed into three groups: Control group (wound treatment with distilled water); Collagenase group (treatment with collagenase ointment); and Rose Hip group (wound treatment with Rose Hip oil). Each group was distributed according to the date of euthanasia: 7, 14 and 21 days. ...

  6. Studies on hip fracture patients : effects of nutrition and rehabilitation

    OpenAIRE

    Flodin, Lena

    2015-01-01

    Hip fracture in the elderly is a serious condition associated with increased mortality. Survivors experience an increase in morbidity and disability that affect their independence and quality of life; the outcome for patients with dementia is particularly poor. Many hip fracture patients have signs of malnutrition already on admission and this patient group has been shown to have a lower body mass index (BMI) than aged-matched controls. A catabolic state develops following hip fracture, chara...

  7. Hip Dysplasia: Clinical Signs and Physical Examination Findings.

    Science.gov (United States)

    Syrcle, Jason

    2017-07-01

    Hip dysplasia is a common developmental disorder of the dog, consisting of varying degrees of hip laxity, progressive remodeling of the structures of the hip, and subsequent development of osteoarthritis. It is a juvenile-onset condition, with clinical signs often first evident at 4 to 12 months of age. A tentative diagnosis of hip dysplasia can be made based on signalment, history, and physical examination findings. The Ortolani test is a valuable tool for identifying juvenile dogs affected with this condition. Further diagnostics can then be prioritized, contributing to prompt diagnosis and appropriate treatment. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Hip pain in adults: MR imaging appearance of common causes

    Energy Technology Data Exchange (ETDEWEB)

    Mengiardi, Bernard; Pfirrmann, Christian W.A.; Hodler, Juerg [Orthopaedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland)

    2007-07-15

    To determine the exact origin of hip pain can be challenging. Symptoms apparently originating from the hip may arise from the pelvis, the sacroiliac joint, the lumbar spine, periarticular structures such as muscles and bursae, or from unexpected sites such as the abdominal wall, the genitourinary tract, or the retroperitoneal space. This article reviews the differential diagnosis of hip pain arising from the hip and surrounding structures and the role of different imaging methods with emphasis on magnetic resonance imaging where most recent advances have occurred. (orig.)

  9. The role of the acetabular labrum in hip dysplasia

    DEFF Research Database (Denmark)

    Hartig-Andreasen, Charlotte; Søballe, Kjeld; Troelsen, Anders

    2013-01-01

    A periacetabular osteotomy (PAO) is the preferred joint preserving treatment for young adults with symptomatic hip dysplasia and no osteoarthritis. In symptomatic dysplasia of the hip, there is labral pathology in up to 90% of cases. However, no consensus exists as to whether a labral tear should...... be treated before the periacetabular osteotomy (PAO), treated simultaneously with the PAO, or left alone and only treated if symptoms persist after the PAO. This review is an update of aspects of labral anatomy and function, the etiology of labral tears in hip dysplasia, and diagnostic assessment of labral...... tears, and we discuss treatment strategies for coexisting labral tears and hip dysplasia....

  10. MR findings of transient synovitis of the hip

    International Nuclear Information System (INIS)

    Lee, Jong Sea; Na, Jae Boem; Yoo, Jin Jong; Ahn, In Oak; Chung, Sung Hoon

    2000-01-01

    To evaluate the MR findings of transient synovitis of the hip in children. Between 1993 and 1997, MR imaging was performed in 30 children (male:female 22:8) in whom transient synovitis had been clinically diagnosed. In 20 of these 30 patients, Gd-enhanced study was also performed. The signal intensity of bone marrow of the femur, the synovial enhancement pattern and the amount of hip joint effusion in affected hips were evaluated; the last -mentioned was determined using the volume measurement method. In 29 patients (97%), no abnormal signal intensity was seen in bone marrow of the femur in affected hips. Gd-enhanced MR imaging revealed synovial enhancement of affected hip joints, as follows: minimal enhancement in eight patients (40%), moderate enhancement in eight (40%), and strong enhancement in four (20%). No abnormal enhancement was demonstrated in bone marrow of the femur or adjacent soft tissue. The mean amount of joint effusion of affected hips was 2.7±1.7 (range, 0.2-18.9)ml; statistically, this was much greater than that of contralateral hip (p less than 0.01). The MR findings of transient synovitis of the hip in children were normal bone marrow signal intensity of the femoral head, moderate or strong synovial enhancement, and asymmetric hip joint effusion. (author)

  11. Interventions for Hip Pain in the Maturing Athlete

    Science.gov (United States)

    Gomberawalla, M. Mustafa; Kelly, Bryan T.; Bedi, Asheesh

    2014-01-01

    Context: Femoroacetabular impingement (FAI) alters hip mechanics, results in hip pain, and may lead to secondary osteoarthritis (OA) in the maturing athlete. Hip impingement can be caused by osseous abnormalities in the proximal femur or acetabulum. These impingement lesions may cause altered loads within the hip joint, which result in repetitive collision damage or sheer forces to the chondral surfaces and acetabular labrum. These anatomic lesions and resultant abnormal mechanics may lead to early osteoarthritic changes. Evidence Acquisition: Relevant articles from the years 1995 to 2013 were identified using MEDLINE, EMBASE, and the bibliographies of reviewed publications. Level of Evidence: Level 4. Results: Improvements in hip arthroscopy have allowed FAI to be addressed utilizing the arthroscope. Adequately resecting the underlying osseous abnormalities is essential to improving hip symptomatology and preventing further chondral damage. Additionally, preserving the labrum by repairing the damaged tissue and restoring the suction seal may theoretically help normalize hip mechanics and prevent further arthritic changes. The outcomes of joint-preserving treatment options may be varied in the maturing athlete due to the degree of underlying OA. Irreversible damage to the hip joint may have already occurred in patients with moderate to advanced OA. In the presence of preexisting arthritis, these patients may only experience fair or even poor results after hip arthroscopy, with early conversion to hip replacement. For patients with advanced hip arthritis, total hip arthroplasty remains a treatment option to reliably improve symptoms with good to excellent outcomes and return to low-impact activities. Conclusion: Advances in the knowledge base and treatment techniques of intra-articular hip pain have allowed surgeons to address this complex clinical problem with promising outcomes. Traditionally, open surgical dislocations for hip preservation surgery have shown good

  12. US of the hips in skeletal dysplasias and chromosomal aberrations

    International Nuclear Information System (INIS)

    Langer, R.; Langer, M.F.J.; Zwicker, C.

    1987-01-01

    Since January 1984 all newborns and infants with skeletal dysplasias and chromosomal aberrations were investigated by hip US, in addition to plain x-ray surveys. The authors observed one chondroectodermal dysplasia, one congenital spondyloepiphysial dysplasia, one cleidocranial dysplasia, one fibrochondrogenesis, two diastrophic dysplasias, and eight trisomies. The abnormalities of the hip joints could be demonstrated, and were compared with the findings on plain films. Especially skeletal dysplasias with abundant presence of cartilage were well visible. The newborn with trisomies showed normal hip joints. In the authors' opinion, all newborns with skeletal dysplasias should be investigated by hip sonography, in addition to skeletal radiography

  13. Traumatic Anterior Dislocation of Hip in a Child- Case Report

    Directory of Open Access Journals (Sweden)

    S Ahmad

    2015-03-01

    Full Text Available Traumatic hip dislocation in children is relatively rare accounting for about 5% of all hip dislocations. Most of the hip dislocations seen in children are of the posterior type but the much rarer anterior and anterior-inferior (obturator types have also been described. We present the case of an eight years old girl with an obturator type of hip dislocation following trivial trauma. She was treated with closed reduction and immobilisation in skin traction for three weeks. She was followed up closely for one year and did not develop any complications during that period.

  14. Comparison of three methods to diagnose hip dysplasia in dogs

    International Nuclear Information System (INIS)

    Sharma, Vikas; Mohindroo, J.

    2009-01-01

    The present study was designed to compare the usefulness of goniometry, radiography and distraction index in diagnosis of hip dysplasia in dogs. During the study 25 clinical cases (50 joints) suspected for hip dysplasia were evaluated. Norberg angle was found to have a significant positive correlation with extension, flexion, abduction, and adduction angles and a significant negative correlation with distraction index (DI) measurements. It could be inferred that all the six parameters (NA, DI, extension, flexion, abduction, and adduction) were reliable indicators for early diagnosis of hip dysplasia.Goniometry could be used as a safe and easy method for preliminary suspicion of hip dysplasia

  15. Hip pain in adults: MR imaging appearance of common causes

    International Nuclear Information System (INIS)

    Mengiardi, Bernard; Pfirrmann, Christian W.A.; Hodler, Juerg

    2007-01-01

    To determine the exact origin of hip pain can be challenging. Symptoms apparently originating from the hip may arise from the pelvis, the sacroiliac joint, the lumbar spine, periarticular structures such as muscles and bursae, or from unexpected sites such as the abdominal wall, the genitourinary tract, or the retroperitoneal space. This article reviews the differential diagnosis of hip pain arising from the hip and surrounding structures and the role of different imaging methods with emphasis on magnetic resonance imaging where most recent advances have occurred. (orig.)

  16. Early diagnosis of congenital dislocation of the hip

    International Nuclear Information System (INIS)

    Grill, F.

    1984-01-01

    Neonatal hip examination is only effective with the help of a large number of experts. Teamwork between pediatrician, pediatric orthopedic surgeon and general practitioner seems to be essential. Best results can be achieved with a hip examination during the first 4 days of life and controls with 3 months and with 12 months. The technic of clinical examination and diagnosis is described. Because of hip dysplasias without any clinical signs the importance of an x-ray of the hip with an age of 3 months is emphasized. (Author)

  17. Case of Transient Osteoporosis of the Hip in Pregnancy

    Directory of Open Access Journals (Sweden)

    Hamza Sucuoğlu

    2014-12-01

    Full Text Available Transient osteoporosis of the hip is an uncommon disease, the cause is not known. It is usually seen in women in the third trimester of pregnancy and in middle-aged men. Patients present with acute, severe hip pain which generally resulting in gait disorder. Prognosis of transient osteoporosis of the hip is good. Within few months of appropriate conservative aproach and bed rest patient’s complains can be fully recovered. In this article; we present the clinical features, diagnosis and treatment options of patients presented to our clinic with severe bilateral hip pain during the third trimester of pregnancy diagnosed as transient osteoporosis accompanied by literature review.

  18. Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement

    Science.gov (United States)

    Zhang, Dagang; Chen, Long; Wang, Guanglin

    2016-01-01

    Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133

  19. Prosthetic hip joint infection due to Campylobacter fetus.

    OpenAIRE

    Bates, C J; Clarke, T C; Spencer, R C

    1994-01-01

    A case of postoperative prosthetic hip joint infection due to Campylobacter fetus subsp. fetus is described. Difficulties in isolation and antimicrobial susceptibility testing of this organism are discussed.

  20. Material development in the SI{sub 3}N{sub 4} system using glass encapsulated Hip`ing. Final report, Phase 2: DOE/ORNL Ceramic Technology Project

    Energy Technology Data Exchange (ETDEWEB)

    Corbin, N.D.; Sundberg, G.J.; Siebein, K.N.; Willkens, C.A.; Pujari, V.K.; Rossi, G.A.; Hansen, J.S.; Chang, C.L.; Hammarstrom, J.L.

    1992-04-01

    This report covers a two-year program to develop fully dense Si{sub 3}N{sub 4} matrix SiC whisker composites with enhanced properties over monolithic Si{sub 3}N{sub 4} materials. The primary goal was to develop a composite with a fracture toughness > 10 MPa{radical}m, capable of using high pressure glass encapsulated HIP`ing. Coating methods were developed to apply thin (<150nm) stoichiometric BN layers to SiC whiskers and also to apply a dual coating of SiC over carbon to the whiskers. Fracture toughness of the composites was determined to increase as the quantity of whiskers (or elongated grains) with their axis perpendicular to the crack plane increased. Of the interface compositions evaluated in this effort, carbon was determined to be the most effective for increasing toughness. The highest toughnesses (6.8--7.0 MPa{radical}m) were obtained with uniaxially aligned carbon coated whiskers. There was no evidence of the carbon coating compromising the oxidation resistance of the composites at 1370{degree}C.

  1. Dynamic behavior of tripolar hip endoprostheses under physiological conditions and their effect on stability.

    Science.gov (United States)

    Fabry, Christian; Kaehler, Michael; Herrmann, Sven; Woernle, Christoph; Bader, Rainer

    2014-01-01

    Tripolar systems have been implanted to reduce the risk of recurrent dislocation. However, there is little known about the dynamic behavior of tripolar hip endoprostheses under daily life conditions and achieved joint stability. Hence, the objective of this biomechanical study was to examine the in vivo dynamics and dislocation behavior of two types of tripolar systems compared to a standard total hip replacement (THR) with the same outer head diameter. Several load cases of daily life activities were applied to an eccentric and a concentric tripolar system by an industrial robot. During testing, the motion of the intermediate component was measured using a stereo camera system. Additionally, their behavior under different dislocation scenarios was investigated in comparison to a standard THR. For the eccentric tripolar system, the intermediate component demonstrated the shifting into moderate valgus-positions, regardless of the type of movement. This implant showed the highest resisting torque against dislocation in combination with a large range of motion. In contrast, the concentric tripolar system tended to remain in varus-positions and was primarily moved after stem contact. According to the results, eccentric tripolar systems can work well under in vivo conditions and increase hip joint stability in comparison to standard THRs. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. A preliminary biomechanical study of a novel carbon-fibre hip implant versus standard metallic hip implants.

    Science.gov (United States)

    Bougherara, Habiba; Zdero, Rad; Dubov, Anton; Shah, Suraj; Khurshid, Shaheen; Schemitsch, Emil H

    2011-01-01

    Total hip arthroplasty is a widespread surgical approach for treating severe osteoarthritis of the human hip. Aseptic loosening of standard metallic hip implants due to stress shielding and bone loss has motivated the development of new materials for hip prostheses. Numerically, a three-dimensional finite element (FE) model that mimicked hip implants was used to compare a new hip stem to two commercially available implants. The hip implants simulated were a novel CF/PA12 carbon-fibre polyamide-based composite hip stem, the Exeter hip stem (Stryker, Mahwah, NJ, USA), and the Omnifit Eon (Stryker, Mahwah, NJ, USA). A virtual axial load of 3 kN was applied to the FE model. Strain and stress distributions were computed. Experimentally, the three hip stems had their distal portions rigidly mounted and had strain gauges placed along the surface at 3 medial and 3 lateral locations. Axial loads of 3 kN were applied. Measurements of axial stiffness and strain were taken and compared to FE analysis. The overall linear correlation between FE model versus experimental strains showed reasonable results for the lines-of-best-fit for the Composite (Pearson R(2)=0.69, slope=0.82), Exeter (Pearson R(2)=0.78, slope=0.59), and Omnifit (Pearson R(2)=0.66, slope=0.45), with some divergence for the most distal strain locations. From FE analysis, the von Mises stress range for the Composite stem was much lower than that in the Omnifit and Exeter implants by 200% and 45%, respectively. The preliminary experiments showed that the Composite stem stiffness (1982 N/mm) was lower than the metallic hip stem stiffnesses (Exeter, 2460 N/mm; Omnifit, 2543 N/mm). This is the first assessment of stress, strain, and stiffness of the CF/PA12 carbon-fibre hip stem compared to standard commercially-available devices. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Gait symmetry and hip strength in women with developmental dysplasia following hip arthroplasty compared to healthy subjects : A cross-sectional study

    NARCIS (Netherlands)

    Leijendekkers, Ruud A.; Marra, Marco A.; Kolk, Sjoerd; Van Bon, Geert; Schreurs, B. Wim; Weerdesteyn, Vivian; Verdonschot, Nico

    2018-01-01

    Introduction: Untreated unilateral developmental dysplasia of the hip (DDH) results in asymmetry of gait and hip strength and may lead to early osteoarthritis, which is commonly treated with a total hip arthroplasty (THA). There is limited knowledge about the obtained symmetry of gait and hip

  4. Evaluation of formal methods in hip joint center assessment: an in vitro analysis.

    Science.gov (United States)

    Lopomo, Nicola; Sun, Lei; Zaffagnini, Stefano; Giordano, Giovanni; Safran, Marc R

    2010-03-01

    The hip joint center is a fundamental landmark in the identification of lower limb mechanical axis; errors in its location lead to substantial inaccuracies both in joint reconstruction and in gait analysis. Actually in Computer Aided Surgery functional non-invasive procedures have been tested in identifying this landmark, but an anatomical validation is scarcely discussed. A navigation system was used to acquire data on eight cadaveric hips. Pivoting functional maneuver and hip joint anatomy were analyzed. Two functional methods - both with and without using the pelvic tracker - were evaluated: specifically a sphere fit method and a transformation techniques. The positions of the estimated centers with respect to the anatomical center of the femoral head, the influence of this deviation on the kinematic assessment and on the identification of femoral mechanical axis were analyzed. We found that the implemented transformation technique was the most reliable estimation of hip joint center, introducing a - Mean (SD) - difference of 1.6 (2.7) mm from the anatomical center with the pelvic tracker, whereas sphere fit method without it demonstrated the lowest accuracy with 25.2 (18.9) mm of deviation. Otherwise both the methods reported similar accuracy (<3mm of deviation). The functional estimations resulted in the best case to be in an average of less than 2mm from the anatomical center, which corresponds to angular deviations of the femoral mechanical axis smaller than 1.7 (1.3) degrees and negligible errors in kinematic assessment of angular displacements.

  5. Minimum Lateral Bone Coverage Required for Securing Fixation of Cementless Acetabular Components in Hip Dysplasia

    Directory of Open Access Journals (Sweden)

    Masanori Fujii

    2017-01-01

    Full Text Available Objectives. To determine the minimum lateral bone coverage required for securing stable fixation of the porous-coated acetabular components (cups in hip dysplasia. Methods. In total, 215 primary total hip arthroplasties in 199 patients were reviewed. The average follow-up period was 49 months (range: 24–77 months. The lateral bone coverage of the cups was assessed by determining the cup center-edge (cup-CE angle and the bone coverage index (BCI from anteroposterior pelvic radiographs. Further, cup fixation was determined using the modified DeLee and Charnley classification system. Results. All cups were judged to show stable fixation by bone ingrowth. The cup-CE angle was less than 0° in 7 hips (3.3% and the minimum cup-CE angle was −9.2° (BCI: 48.8%. Thin radiolucent lines were observed in 5 hips (2.3%, which were not associated with decreased lateral bone coverage. Loosening, osteolysis, dislocation, or revision was not observed in any of the cases during the follow-up period. Conclusion. A cup-CE angle greater than −10° (BCI > 50% was acceptable for stable bony fixation of the cup. Considering possible errors in manual implantation, we recommend that the cup position be planned such that the cup-CE angle is greater than 0° (BCI > 60%.

  6. Joint angles of the ankle, knee, and hip and loading conditions during split squats.

    Science.gov (United States)

    Schütz, Pascal; List, Renate; Zemp, Roland; Schellenberg, Florian; Taylor, William R; Lorenzetti, Silvio

    2014-06-01

    The aim of this study was to quantify how step length and the front tibia angle influence joint angles and loading conditions during the split squat exercise. Eleven subjects performed split squats with an additional load of 25% body weight applied using a barbell. Each subject's movements were recorded using a motion capture system, and the ground reaction force was measured under each foot. The joint angles and loading conditions were calculated using a cluster-based kinematic approach and inverse dynamics modeling respectively. Increases in the tibia angle resulted in a smaller range of motion (ROM) of the front knee and a larger ROM of the rear knee and hip. The external flexion moment in the front knee/hip and the external extension moment in the rear hip decreased as the tibia angle increased. The flexion moment in the rear knee increased as the tibia angle increased. The load distribution between the legs changed squat execution was varied. Our results describing the changes in joint angles and the resulting differences in the moments of the knee and hip will allow coaches and therapists to adapt the split squat exercise to the individual motion and load demands of athletes.

  7. Bilateral, Misalignment-Compensating, Full-DOF Hip Exoskeleton: Design and Kinematic Validation

    Directory of Open Access Journals (Sweden)

    Karen Junius

    2017-01-01

    Full Text Available A shared design goal for most robotic lower limb exoskeletons is to reduce the metabolic cost of locomotion for the user. Despite this, only a limited amount of devices was able to actually reduce user metabolic consumption. Preservation of the natural motion kinematics was defined as an important requirement for a device to be metabolically beneficial. This requires the inclusion of all human degrees of freedom (DOF in a design, as well as perfect alignment of the rotation axes. As perfect alignment is impossible, compensation for misalignment effects should be provided. A misalignment compensation mechanism for a 3-DOF system is presented in this paper. It is validated by the implementation in a bilateral hip exoskeleton, resulting in a compact and lightweight device that can be donned fast and autonomously, with a minimum of required adaptations. Extensive testing of the prototype has shown that hip range of motion of the user is maintained while wearing the device and this for all three hip DOFs. This allowed the users to maintain their natural motion patterns when they are walking with the novel hip exoskeleton.

  8. Bilateral, Misalignment-Compensating, Full-DOF Hip Exoskeleton: Design and Kinematic Validation

    Science.gov (United States)

    Degelaen, Marc; Lefeber, Nina; Swinnen, Eva; Vanderborght, Bram; Lefeber, Dirk

    2017-01-01

    A shared design goal for most robotic lower limb exoskeletons is to reduce the metabolic cost of locomotion for the user. Despite this, only a limited amount of devices was able to actually reduce user metabolic consumption. Preservation of the natural motion kinematics was defined as an important requirement for a device to be metabolically beneficial. This requires the inclusion of all human degrees of freedom (DOF) in a design, as well as perfect alignment of the rotation axes. As perfect alignment is impossible, compensation for misalignment effects should be provided. A misalignment compensation mechanism for a 3-DOF system is presented in this paper. It is validated by the implementation in a bilateral hip exoskeleton, resulting in a compact and lightweight device that can be donned fast and autonomously, with a minimum of required adaptations. Extensive testing of the prototype has shown that hip range of motion of the user is maintained while wearing the device and this for all three hip DOFs. This allowed the users to maintain their natural motion patterns when they are walking with the novel hip exoskeleton. PMID:28790799

  9. [Association between hip fractures and risk factors for osteoporosis. Multivariate analysis].

    Science.gov (United States)

    Masoni, Ana; Morosano, Mario; Tomat, María Florencia; Pezzotto, Stella M; Sánchez, Ariel

    2007-01-01

    In this observational, case-control study, 376 inpatients were evaluated in order to determine the association of risk factors (RF) and hip fracture; 151 patients had osteoporotic hip fracture (cases); the remaining were controls. Data were obtained from medical charts, and through a standardized questionnaire about RF. Mean age of the sample (+/- SD) was 80.6 +/- 8.1 years, without statistically significant difference between cases and controls; the female:male ratio was 3:1 in both groups. Fractured women were older than men (82.5 +/- 8.1 vs. 79.7 +/- 7.2 years, respectively; p household duties was a RF (p = 0.007), which was absent in males. In multivariate analysis, the following RF were significantly more frequent: Cognitive impairment (p = 0.001), and previous falls (p < 0.0001); whereas the following protective factors were significantly different from controls: Calcium intake during youth (p < 0.0001), current calcium intake (p < 0.0001), and mechanical aid for walking (p < 0.0001). Evaluation of RF and protective factors may contribute to diminish the probability of hip fracture, through a modification of personal habits, and measures to prevent falls among elderly adults. Present information can help to develop local and national population-based strategies to diminish the burden of hip fractures for the health system.

  10. Clinical application of the modified medially-mounted motor-driven hip gear joint for paraplegics.

    Science.gov (United States)

    Sonoda, S; Imahori, R; Saitoh, E; Tomita, Y; Domen, K; Chino, N

    2000-04-15

    This paper describes a motor-driven orthosis for paraplegics which has been developed. This orthosis is composed of a medially-mounted motor-driven hip joint and bilateral knee-ankle-foot orthosis. With the gear mechanism, the virtual axis of the hip joint of this orthosis is almost as high as the anatomical hip joint. A paraplegic patient with an injury level of T10/11 walked using bilateral lofstrand crutches and this new orthosis with or without the motor system. The motor is initiated by pushing a button attached at the edge of the grab of the crutches. Faster cadence and speed and smaller rotation angle of the trunk was obtained in motor walking compared with non-motor walking. The patient did not feel fearful of falling. The benefit of motor orthosis is that it can be used even in patients with lower motor lesions and that it provides stable regulation of hip flexion movement in spastic patients. In conclusion, this motor orthosis will enhance paraplegic walking.

  11. Integrated nutritional intervention in the elderly after hip fracture. A process evaluation.

    Science.gov (United States)

    Breedveld-Peters, José J L; Reijven, Petronella L M; Wyers, Caroline E; van Helden, Svenhjalmar; Arts, J J Chris; Meesters, Berry; Prins, Martin H; van der Weijden, Trudy; Dagnelie, Pieter C

    2012-04-01

    Within a multicentre randomized controlled trial aimed at improving the nutritional status and increase the speed of recovery of elderly hip fracture patients, we performed a process evaluation to investigate the feasibility of the intervention within the present Dutch health care system. Patients in the intervention group received nutritional counseling during 10 contacts. Oral nutritional supplements were advised as needed until three months after hip fracture surgery. The intervention was evaluated with respect to dieticians' adherence to the study protocol, content of nutritional counseling, and patients' adherence to recommendations given. We included 66 patients (mean age of 76, range 55-92 years); 74% women. Eighty-three percent of patients received all 10 contacts as planned, but in 62% of the patients one or more telephone calls had to be replaced by face to face contacts. Nutritional counseling was complete in 91% of contacts. Oral nutritional supplementation was needed for a median period of 76 days; 75% of the patients took the oral nutritional supplements as recommended. Nutritional counseling in elderly hip fracture patients through face to face contacts and telephone calls is feasible. However, individual tailoring of the intervention is recommended. The majority of hip fracture patients needed >2 months oral nutritional supplements to meet their nutritional requirements. The trial was registered at clincialtrails.gov as NCT00523575. Copyright © 2011 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  12. Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty.

    Science.gov (United States)

    Kaipel, Martin; Grabowiecki, Phillip; Sinz, Katrina; Farr, Sebastian; Sinz, Günter

    2015-05-01

    Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10%) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90%) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.

  13. Coordination pays off: a comparison of two models for organizing hip fracture care, outcomes and costs.

    Science.gov (United States)

    Löfgren, Susanne; Rehnberg, Clas; Ljunggren, Gunnar; Brommels, Mats

    2015-01-01

    With the "graying" of the population, hip fractures place an increasing burden on health systems and call for efficient forms of care. The aim was to compare two models of organizing hip fracture care at one university hospital working at two sites. The differences in organization were coordinated care provided in one of the sites and traditional care, divided between different institutions, in the other. The study was conducted at a Swedish university hospital and included all 503 hip fracture patients, admitted during the 1-year period of February 2009 through January 2010. Patient gender, age, type of fracture, admission and discharge dates were documented. The patients were surveyed of their health-related quality of life at the time of admission and at 4 and 12 months after discharge. The costs for the inpatient care episode were estimated using three costing methods. The coordinated care model resulted in a shorter hospital stay and consistently lower costs. There was no difference between patient-reported quality of life. The care of hip fracture patients coordinated by a geriatric ward throughout the whole care episode is more cost-efficient than uncoordinated where patients are transferred to other institutions for rehabilitation. © 2014 The Authors. The International Journal of Health Planning and Management published by John Wiley & Sons Ltd.

  14. Rationing of hip and knee referrals in the public hospital: the true unmet need.

    Science.gov (United States)

    Inglis, Tom; Armour, Paul; Inglis, Grahame; Hooper, Gary

    2017-03-24

    The aim of this paper is to outline the development of a triage system for elective hip and knee referrals to the Orthopaedic Department of the Canterbury District Health Board (CDHB), and to determine the unmet need within this population for accessing first specialist assessment (FSA). Between 1 August 2015 and 31 March 2016 data was collected from all elective hip and knee referrals that underwent triage for a FSA. The number of outpatient appointments available according to the government four-month waiting time is set by the CDHB. Patients were triaged by two consultant surgeons on the basis of their referral letter and radiological imaging into one of five categories: accepted for FSA, insufficient information, no capacity, low priority or direct entry to waiting list (if already seen by a specialist). Those not accepted for an FSA were returned to general practitioner (GP) care. During the study period there were 1,733 referrals (838 hip related referrals and 895 knee related referrals) to the orthopaedic department with a request for FSA. All patients had failed conservative management. Of these referrals 43% of hip and 54% of knee related referrals could not be offered an FSA and were returned, following triage, to general practitioner care unseen. Only 8% and 9% respectively were declined for insufficient information in the referral letter or lack of need. This study details the implementation of a triage system for elective hip and knee referrals to the CDHB and with accurate data we have been able to determine the large number of patients unable to access a specialist opinion. These patients represent the unmet need within our community and highlights the degree of rationing taking place within the public hospital.

  15. Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis 5-year follow-up of 52 patients

    DEFF Research Database (Denmark)

    Gustafson, Klas; Jakobsen, Stig S; Lorenzen, Nina D

    2014-01-01

    to an increased incidence of metal allergy. METHODS: 52 hips in 52 patients (median age 60 (51-64) years, 30 women) were randomized to either a MOM hip resurfacing system (ReCap) or a standard MOP total hip arthoplasty (Mallory Head/Exeter). Spot urine samples were collected preoperatively, postoperatively, after....... RESULTS: A statistically significant 10- to 20-fold increase in urinary levels of cobalt and chromium was observed throughout the entire follow-up in the MOM group. The prevalence of metal allergy was similar between groups. INTERPRETATION: While we observed significantly increased levels of metal ions...

  16. Ultraviolet radiation and air contamination during total hip replacement

    International Nuclear Information System (INIS)

    Carlsson, A.S.; Nilsson, B.; Walder, M.H.; Osterberg, K.

    1986-01-01

    Ultraviolet (uv) radiation of the operating room was assessed bacteriologically in an open randomized study of 30 total hip procedures. Volumetric air-sampling demonstrated that the number of colony forming units (cfu m-3) were significantly reduced (P less than 0.001) by uv light, both close to the wound and in the periphery of the operating room. No adverse effects of the uv-irradiation were observed either in the patients or the staff. In operating rooms fitted with a zonal ventilation system and with an air change rate of about 70 h-1, the addition of uv irradiation during surgery may achieve ultra clean air. However, in conventionally ventilated operating rooms uv-irradiation alone is probably not sufficient to do so

  17. [The Use of Jumbo Cups in Revision Total Hip Arthroplasty].

    Science.gov (United States)

    von Roth, Philipp; Wassilew, Georgi I

    2017-10-01

    Extra-large uncemented jumbo cups are among the most common methods of acetabular revision. Jumbo cups do not contribute to bone stock restoration, and in the case of a subsequent revision, an even larger bone defect is to be expected. Thus, understanding long-term survival is essential. The present article discusses the literature relevant to this topic and addresses technical and implant-specific characteristics of jumbo cups. In summary, jumbo cups show an acceptable long-term survival rate, with aseptic loosening as the most common reason for revision and dislocation being the most common complication. Through the development of alternative revision systems, jumbo cups have lost their importance in today's practice. However, they can serve as a benchmark for studies of newer technologies in revision total hip arthroplasty. Georg Thieme Verlag KG Stuttgart · New York.

  18. Magnetic resonance imaging in children with acute hip pain

    Energy Technology Data Exchange (ETDEWEB)

    Ranner, G.; Ebner, F.; Fotter, R.; Justich, E. (Graz Univ. (Austria). Radiologische Klinik); Linhart, W. (Graz Univ. (Austria). Kinderklinik)

    1989-11-01

    45 children presenting with acute hip pain were prospectively evaluated with conventional radiography, radioisotope bone scan, and magnetic resonance imaging (MRI). The final diagnoses were transient synovitis (n=17), septic arthritis (n=2), Legg-Calve-Perthes disease (LCPD, n=13), epiphyseal dysplasia (n=2), other conditions (n=4), and normal findings (n=7). In the work-up MRI provided more morphologic information than other techniques and enlarged the diagnostic possibilities. It was the only imaging technique able to give an early indication of bone marrow involvement in systemic diseases. For the early diagnosis of LCPD, MRI was as sensitive as isotope bone scan and more precise than conventional radiography. In the follow-up of LCPD patients MRI was not able to indicate the start of revascularisation of the necrotic area, which bone scans showed reliably in six patients: But MRI provided excellent evaluation of the position, form and size of the femoral head and the surrounding soft tissues. (orig.).

  19. Pressure sores following elective total hip arthroplasty: pitfalls of misinterpretation.

    Science.gov (United States)

    Keong, Nicole; Ricketts, David; Alakeson, Nuki; Rust, Philippa

    2004-01-01

    OBJECTIVE: To assess the reliability of reporting protocols regarding pressure sores. METHODS: Retrospective data were collected regarding pressure sore rates following total hip arthroplasty operations carried out during 2001 at two orthopaedic units in an NHS hospital (Princess Royal Hospital) and in a local private hospital. RESULTS: Preliminary results presented in audit and interim reports indicated an alarmingly high pressure sore rate across the two sites (17/172 [9.9%] NHS, 23/71 [32.4%] private hospital). On analysis, the data collection system was revealed to be flawed. Grade 1 areas (erythema with no ulceration) were included, leading to a dramatic discrepancy between reported and confirmed pressure sores. Re-analysis showed the confirmed pressure sore rates to be much lower (2.3% NHS, 1.0% private hospital). CONCLUSIONS: This audit suggests that both poor data collection and education lead to inaccurate audit. This may lead to subsequent inappropriate management and inappropriate NHS star ratings. PMID:15140301

  20. Irrigation and Debridement with Component Retention for Acute Infection After Hip Arthroplasty: Improved Results with Contemporary Management.

    Science.gov (United States)

    Bryan, Andrew J; Abdel, Matthew P; Sanders, Thomas L; Fitzgerald, Steven F; Hanssen, Arlen D; Berry, Daniel J

    2017-12-06

    There are conflicting data on the results of irrigation and debridement with component retention in patients with acute periprosthetic hip infections. The goals of this study were to examine contemporary results of irrigation and debridement with component retention for acute infection after primary hip arthroplasty and to identify host, organism, antibiotic, or implant factors that predict success or failure. Ninety hips (57 total hip arthroplasties and 33 hemiarthroplasties) were diagnosed with acute periprosthetic hip infection (using strict criteria) and were treated with irrigation and debridement and component retention between 2000 and 2012. The mean follow-up was 6 years. Patients were stratified on the basis of McPherson criteria. Hips were managed with irrigation and debridement and retention of well-fixed implants with modular head and liner exchange (70%) or irrigation and debridement alone (30%). Seventy-seven percent of patients were treated with chronic antibiotic suppression. Failure was defined as failure to eradicate infection, characterized by a wound fistula, drainage, intolerable pain, or infection recurrence caused by the same organism strain; subsequent removal of any component for infection; unplanned second wound debridement for ongoing deep infection; and/or occurrence of periprosthetic joint infection-related mortality. Treatment failure occurred in 17% (15 of 90 hips), with component removal secondary to recurrent infection in 10% (9 of 90 hips). Treatment failure occurred in 15% (10 of 66 hips) after early postoperative infection and 21% (5 of 24 hips) after acute hematogenous infection (p = 0.7). Patients with McPherson host grade A had a treatment failure rate of 8%, compared with 16% (p = 0.04) in host grade B and 44% in host grade C (p = 0.006). Most treatment failures (12 of 15 failures) occurred within the initial 6 weeks of treatment; failures subsequent to 6 weeks occurred in 3% of those treated with chronic antibiotic