WorldWideScience

Sample records for spectrometric techniques etude

  1. Spectrometric techniques 4

    CERN Document Server

    Vanasse, George A

    2013-01-01

    Spectrometric Techniques, Volume IV discusses three widely diversified areas of spectrometric techniques. The book focuses on three spectrometric methods. Chapter 1 discusses the phenomenology and applications of Coherent Anti-Stokes Raman Spectroscopy (CARS), the most commonly used optical technique that exploit the Raman effect. The second chapter is concerned with diffraction gratings and mountings for the Vacuum Ultraviolet Spectral Region. Chapter 3 accounts the uses of mass spectrometry, detectors, types of spectrometers, and ion sources. Physicists and chemists will find the book a go

  2. Spectrometric techniques 3

    CERN Document Server

    Vanasse, George A

    2013-01-01

    Spectrometric Techniques, Volume III presents the applications of spectrometric techniques to atmospheric and space studies. This book reviews the spectral data processing and analysis techniques that are of broad applicability.Organized into five chapters, this volume begins with an overview of the instrumentation used for obtaining field data. This text then reviews the contribution that space-borne spectroscopy in the thermal IR has made to the understanding of the planets. Other chapters consider the instruments that have recorded the planetary emission spectra. This book discusses as well

  3. Spectrometric techniques 2

    CERN Document Server

    Vanasse, George A

    2013-01-01

    Spectrometric Techniques, Volume II provides information pertinent to vacuum ultraviolet techniques to complete the demonstration of the diversity of methods available to the spectroscopist interested in the ultraviolet visible and infrared spectral regions. This book discusses the specific aspects of the technique of Fourier transform spectroscopy.Organized into five chapters, this volume begins with an overview of the large number of systematic effects in the recording of an interferogram. This text then examines the design approach for a Fourier transform spectrometer with focus on optics.

  4. Commercial Applications of X Ray Spectrometric Techniques

    International Nuclear Information System (INIS)

    Wegrzynek, D.

    2013-01-01

    In the 21st century, the X-ray fluorescence (XRF) technique is widely used in process control, industrial applications and for routine elemental analysis. The technique has a multielement capability capable of detecting elements with Z ≥ 10, with a few instruments capable of detecting also elements with Z ≥ 5. It is characterized by a non-destructive analysis process and relatively good detection limits, typically one part per million, for a wide range of elements. The first commercial XRF instruments were introduced to the market about 50 years ago. They were the wavelength dispersive X ray fluorescence (WDXRF) spectrometers utilizing Bragg’s law and reflection on crystal lattices for sequential elemental analysis of sample composition. The advances made in radiation detector technology, especially the introduction of semiconductor detectors, improvements in signal processing electronics, availability and exponential growth of personal computer market led to invention of energy dispersive X ray fluorescence (EDXRF) technique. The EDXRF is more cost effective as compared to WDXRF. It also allows for designing compact instruments. Such instruments can be easily tailored to the needs of different customers, integrated with industrial installations, and also miniaturized for the purpose of in-situ applications. The versatility of the technique has been confirmed in a spectacular way by using the XRF and X-ray spectrometric techniques, among few others, during the NASA and ESA missions in search for the evidence of life and presence of water on the surface of Mars. The XRF technique has achieved its strong position within the atomic spectroscopy group of analytical techniques not only due to its versatility but also due to relatively low running costs, as compared to the commonly used methods, e.g., atomic absorption spectrometry (AAS) or inductively coupled plasma atomic emission/mass spectrometry (ICP-AES/MS). Presently, the XRF technique together with X ray

  5. Commercial Applications of X Ray Spectrometric Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wegrzynek, D., E-mail: D.Wedgrznek@iaea.org [International Atomic Energy Agency, The IAEA Laboratories, Seibersdorf, Vienna (Austria)

    2013-07-15

    In the 21st century, the X-ray fluorescence (XRF) technique is widely used in process control, industrial applications and for routine elemental analysis. The technique has a multielement capability capable of detecting elements with Z {>=} 10, with a few instruments capable of detecting also elements with Z {>=} 5. It is characterized by a non-destructive analysis process and relatively good detection limits, typically one part per million, for a wide range of elements. The first commercial XRF instruments were introduced to the market about 50 years ago. They were the wavelength dispersive X ray fluorescence (WDXRF) spectrometers utilizing Bragg's law and reflection on crystal lattices for sequential elemental analysis of sample composition. The advances made in radiation detector technology, especially the introduction of semiconductor detectors, improvements in signal processing electronics, availability and exponential growth of personal computer market led to invention of energy dispersive X ray fluorescence (EDXRF) technique. The EDXRF is more cost effective as compared to WDXRF. It also allows for designing compact instruments. Such instruments can be easily tailored to the needs of different customers, integrated with industrial installations, and also miniaturized for the purpose of in-situ applications. The versatility of the technique has been confirmed in a spectacular way by using the XRF and X-ray spectrometric techniques, among few others, during the NASA and ESA missions in search for the evidence of life and presence of water on the surface of Mars. The XRF technique has achieved its strong position within the atomic spectroscopy group of analytical techniques not only due to its versatility but also due to relatively low running costs, as compared to the commonly used methods, e.g., atomic absorption spectrometry (AAS) or inductively coupled plasma atomic emission/mass spectrometry (ICP-AES/MS). Presently, the XRF technique together with X ray

  6. Development of a gas-ionization {beta}-spectrometer; Etude et realisation d'un spectrometre {beta} a ionisation gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Le Du, R [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1968-05-15

    We intend to develop in our laboratory a {beta}-spectrometer. This apparatus will have two main objectives: 1 - the determination of the nature and the degree of purity of certain {beta}-emitting radioactive substances; 2 - the study of an activity calibration process for {beta}-emitting radioactive sources. (author) [French] Nous nous proposons d'etudier et de realiser dans notre laboratoire un spectrometre {beta}. Cet appareil aura deux buts principaux: 1 - determiner la nature et le degre de purete de certains corps radioactifs emetteurs {beta}; 2 - permettre l'etude d'un procede d'etalonnage en activite de sources radioactives emetteurs {beta}. (auteur)

  7. Theoretical study, and construction, of a spherical electrostatic beta spectrometer; Etude theorique et realisation d'un spectrometre beta electrostatique spherique

    Energy Technology Data Exchange (ETDEWEB)

    Moret, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1964-03-15

    After a literature survey showing the importance of an electrostatic spectrometer with spherical electrodes for studying disintegration processes, the theoretical characteristics of such an apparatus are derived (determination of the trajectory equations calculation of the transmission and of the resolving power the case of a point source and of an extended source). The apparatus built as a result of these calculations is described. The electrostatic field distribution outside the electrodes is derived. As well as giving electron spectra ({beta} disintegration and conversion electrons) the apparatus make s it possible to study e-{gamma}, e-{beta}, e-e-{gamma} and e-e-{beta} coincidences. In the last part are given experimental characteristics and the results of the first measurements made on conversion electron spectra ({sup 161}Tb, {sup 151}Pm, {sup 155}Eu) and on coincidences ({sup 170}Tm) using this spectrometer. (author) [French] Apres une etude bibliographique montrant l'interet que presente un spectrometre electrostatique a electrodes spheriques pour l'etude des schemas de desintegration, l'auteur etablit les caracteristiques theoriques d'un tel appareil (determination de l'equation des trajectoires calcul de la transmission et du pouvoir de resolution cas d'une source ponctuelle et d'une source etendue). On decrit l'appareil realise d'apres ces calculs. On etablit la repartition du champ electrostatique a l'exterieur des electrodes. Outre le trace des spectres d'electrons (desintegration {beta} et electrons de conversion), l'appareil permet l'etude de coincidences e-{gamma}, e-{beta}, e-e-{gamma} and e-e-{beta}. Dans la derniere partie, sont donnees les caracteristiques experimentales et les premieres etudes de spectres d'electrons de conversion ({sup 161}Tb, {sup 151}Pm, {sup 155}Eu) et de coincidences ({sup 170}Tm) faites a l'aide de ce spectrometre. (auteur)

  8. Mass Spectrometric C-14 Detection Techniques: Progress Report

    Science.gov (United States)

    Synal, H.

    2013-12-01

    Accelerator Mass Spectrometry (AMS) has been established as the best-suited radiocarbon detection technique. In the past years, significant progress with AMS instrumentation has been made resulting in a boom of new AMS facilities around the World. Today, carbon only AMS systems predominantly utilize 1+ charge state and molecule destruction in multiple ion gas collisions in stripper gas cell. This has made possible a significant simplification of the instruments, a reduction of ion energies and related to this less required space of the installations. However, state-of-the-art AMS instruments have still not reached a development stage where they can be regarded as table-top systems. In this respect, more development is needed to further advance the applicability of radiocarbon not only in the traditional fields of dating but also in biomedical research and new fields in Earth and environmental sciences. In a the proof-of-principle experiment the feasibility of radiocarbon detection over the entire range of dating applications was demonstrated using a pure mass spectrometer and ion energies below 50 keV. Now an experimental platform has been completed to test performance and to explore operation and measurement conditions of pure mass spectrometric radiocarbon detection. This contribution will overview the physical principles, which make this development possible and discuss key parameters of the instrumental design and performance of such an instrument.

  9. Review of procedures involving separation and preconcentration for the determination of cadmium using spectrometric techniques

    International Nuclear Information System (INIS)

    Ferreira, Sergio L.C.; Andrade, Jailson B. de; Korn, Maria das Gracas A.; Pereira, Madson de G.; Lemos, Valfredo A.; Santos, Walter N.L. dos; Rodrigues, Frederico de Medeiros; Souza, Anderson S.; Ferreira, Hadla S.; Silva, Erik G.P. da

    2007-01-01

    Spectrometric techniques for the analysis of trace cadmium have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, such as electrochemical deposition, precipitation, coprecipitation, solid phase extraction, liquid-liquid extraction (LLE) and cloud point extraction (CPE), and consider the features of the their application with several spectrometric techniques

  10. Theoretical study and construction of a multichannel {beta} spectrometer with uniform magnetic field; Etude et realisation d'un spectrometre {beta} multivoies a champ magnetique uniforme

    Energy Technology Data Exchange (ETDEWEB)

    Schussler, F [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-09-01

    After a brief survey of the interest of a multichannel beta spectrometer for studying decay schemes of short lived nuclides (30 seconds minimum, the theoretically well known characteristics of uniform magnetic field analyser (image of a large source, transmission and resolution) are briefly remembered. In the second part, the apparatus built as a result of these calculations is described. This apparatus allows the determination of beta spectra by simultaneous determination of the beta spectra in coincidence with four gamma rays predetermined in the gamma spectrum of the studied nuclide. Finally, in the last part, the experimental characteristics of the spectrometer (calibration in energy and transmission) and the first measurement of beta spectra ({sup 155}Sm) and of coincidences ({sup 24}Na), are given. (author) [French] Apres avoir brievement souligne l'interet pratique que presente un spectrometre multivoies pour l'etude des schemas de desintegration des corps radioactifs de courtes periodes (30 secondes au maximum), l'auteur effectue un rappel des caracteristiques theoriques bien connues d'un analyseur magnetique a champ uniforme (image d'une source etendue) calcul de la transmission et du pouvoir de resolution. Une deuxieme partie est consacree a la description de l'appareil realise d'apres ces calculs. Cet appareil permet le releve des spectres beta par detection, simultanee de dix groupes d'electrons d'energies differentes; il permet egalement le releve simultane des spectres beta en coincidence avec quatre rayonnements gammas preselectionnes a l'avance dans le spectre gamma du corps etudie. Dans une derniere partie enfin, sont donnees les caracteristiques experimentales du spectrometre (etalonnage en energie et en transmission) ainsi que les premiers resultats des etudes de spectre beta ({sup 155}Sm) et de coincidence ({sup 24}Na). (auteur)

  11. Low-activity spectrometric gamma-ray logging technique for delineation of coal/rock interfaces in dry blast holes

    International Nuclear Information System (INIS)

    Asfahani, J.; Borsaru, M.

    2007-01-01

    A low-activity spectrometric gamma-ray logging technique is proposed in this paper as a sensitive tool for the delineation of coal/rock interfaces in dry blast holes. The advantages and superiority of this technique over traditional micro-density non-spectrometric gamma-ray tools are demonstrated

  12. Uranium determination using atomic spectrometric techniques: An overview

    International Nuclear Information System (INIS)

    Santos, Juracir S.; Teixeira, Leonardo S.G.; Santos, Walter N.L. dos; Lemos, Valfredo A.; Godoy, Jose M.; Ferreira, Sergio L.C.

    2010-01-01

    This review focuses on the determination of uranium using spectroanalytical techniques that are aimed at total determination such as flame atomic absorption spectrometry (FAAS), electrothermal atomic absorption spectrometry (ETAAS), inductively coupled plasma optical emission spectrometry (ICP-OES); and inductively coupled plasma mass spectrometry (ICP-MS) that also enables the determination of uranium isotopes. The advantages and shortcomings related to interferences, precision, accuracy, sample type and equipment employed in the analysis are taken into account, as well as the complexity and costs (i.e., acquisition, operation and maintenance) associated with each of the techniques. Strategies to improve their performance that employ separation and/or preconcentration steps are considered, with an emphasis given to solid-phase extraction because of its advantages compared to other preconcentration procedures.

  13. Characterization of used lubricating oil by spectrometric techniques

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Andressa Moreira de, E-mail: andressa@ctaa.embrapa.br [Embrapa Agroindustria de Alimentos, Guaratiba, Rio de Janeiro, RJ (Brazil); Correa, Sergio Machado [Faculdade de Engenharia. Universidade do Estado do Rio de Janeiro (UERJ), Resende, RJ (Brazil); Silva, Glauco Correa da [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Full text: The engine lubricating oil drags all kinds of impurities generated by wear of internal components. Thus, it is necessary to monitor the physical and chemical properties and concentration of metals in lubricants used to determine the appropriate time to replace them. Moreover, one can monitor the wear of the engines through the levels of metals in oils. To achieve these goals, some detection techniques such as Flame atomic absorption spectrometry (FAAS), Inductively coupled plasma optical emission spectrometry (ICP-OES) and X-ray fluorescence (XRF), have been widely used to determine metals in lubricating oils and also in other oil derivatives. Thus, some of these techniques were used in this study. Also the technique used was Gas chromatography mass spectrometry (GC / MS) for characterization of chromatographic profile of the engine lubricating oil after use. Through the technique of ICP-OES for method of United States Environmental Protection Agency (USEPA) METHOD 6010B - Inductively coupled plasma optical emission spectrometry was performed to characterize metals in lubricating oil motor, using equipment from ICP-OES Perkin-Elmer{sup R} OPTIMA 3000 ICP-Winlab and software, obtaining the following identification of metals: barium (Ba), calcium (Ca), lead (Pb), copper (Cu), Chromium (Cr), iron (Fe), magnesium (Mg), molybdenum (Mo) and zinc (Zn). Using the XRF technique, through the equipment EDFRX Shimadzu{sup R} model 800HS EDX, Rh tube, applied voltage of 50kV, amperage 100{mu}A, detector Si (Li) cooled with liquid nitrogen and collimator 10mm, we analyzed all the components comprised in the range of Ti to U and Na to SC, identified the following metals: calcium (Ca), zinc (Zn), iron (Fe), copper (Cu), molybdenum (Mo) and nickel (Ni). The characterization was performed by chromatographic methods: USEPA METHOD 5021A - Volatile organic compounds in various sample matrices using equilibrium headspace analysis, USEPA METHOD 8015B - Nonhalogenated Organics

  14. Characterization of used lubricating oil by spectrometric techniques

    International Nuclear Information System (INIS)

    Souza, Andressa Moreira de; Correa, Sergio Machado; Silva, Glauco Correa da

    2011-01-01

    Full text: The engine lubricating oil drags all kinds of impurities generated by wear of internal components. Thus, it is necessary to monitor the physical and chemical properties and concentration of metals in lubricants used to determine the appropriate time to replace them. Moreover, one can monitor the wear of the engines through the levels of metals in oils. To achieve these goals, some detection techniques such as Flame atomic absorption spectrometry (FAAS), Inductively coupled plasma optical emission spectrometry (ICP-OES) and X-ray fluorescence (XRF), have been widely used to determine metals in lubricating oils and also in other oil derivatives. Thus, some of these techniques were used in this study. Also the technique used was Gas chromatography mass spectrometry (GC / MS) for characterization of chromatographic profile of the engine lubricating oil after use. Through the technique of ICP-OES for method of United States Environmental Protection Agency (USEPA) METHOD 6010B - Inductively coupled plasma optical emission spectrometry was performed to characterize metals in lubricating oil motor, using equipment from ICP-OES Perkin-Elmer R OPTIMA 3000 ICP-Winlab and software, obtaining the following identification of metals: barium (Ba), calcium (Ca), lead (Pb), copper (Cu), Chromium (Cr), iron (Fe), magnesium (Mg), molybdenum (Mo) and zinc (Zn). Using the XRF technique, through the equipment EDFRX Shimadzu R model 800HS EDX, Rh tube, applied voltage of 50kV, amperage 100μA, detector Si (Li) cooled with liquid nitrogen and collimator 10mm, we analyzed all the components comprised in the range of Ti to U and Na to SC, identified the following metals: calcium (Ca), zinc (Zn), iron (Fe), copper (Cu), molybdenum (Mo) and nickel (Ni). The characterization was performed by chromatographic methods: USEPA METHOD 5021A - Volatile organic compounds in various sample matrices using equilibrium headspace analysis, USEPA METHOD 8015B - Nonhalogenated Organics Using GC

  15. Sequential mass spectrometric analysis of uranium and plutonium employing resin bead technique

    International Nuclear Information System (INIS)

    Ramakumar, K.L.; Aggarwal, S.K.; Chitambar, S.A.; Jain, H.C.

    1985-01-01

    Sequential mass spectrometric analysis of uranium and plutonium employing anion exchange resin bead technique is reported using a high sensitive single stage magnetic analyser instrument, the routinely employed rhenium double filament assembly and 0.5M HNO 3 as a wetting agent for loading the resin beads. A precision of bettter than 0.3per cent (2sigma) is obtained on the isotopic ratio measurements. However, extreme care has to be exercised to carry the resin bead experiments under ultra clean conditions so as to avoid pick up of contamination. (author)

  16. Determination of trace quantities of uranium in rocks mass spectrometric isotope dilution technique

    International Nuclear Information System (INIS)

    Kakazu, Mauricio Hiromitu

    1980-01-01

    A detailed experimental investigation on the thermionic emission of uranium deposited on a single flat type rhenium filament has been carried out. The study was aimed at determining the influence of various forms of deposition on the emission sensitivity and thermal stability of U + , UO + and UO 2 + ions. Based on these investigations, a technique, involving an addition of a small quantity of colloidal suspension of graphite on top of the uranyl nitrate sample deposited, was chosen because of its higher, emission sensitivity for uranium metal ions. The experimental parameters of the technique were optimised and the technique was employed in the determination of trace quantities of uranium in rock samples using mass spectrometric isotope dilution method. For the mass spectrometric isotope dilution analysis National Bureau of Standards uranium isotopic standard NBS-U 970 was employed as a tracer, where as the mass discrimination effect in the uranium isotope analysis was corrected using the uranium isotopic standard NBS-U500. Uranium was determined in each of the seven granite samples from Wyoming, USA and two USGS standard rocks. The precision of the analysis was found to be ±1% . The uranium values obtained on the rock samples were compared with the analyses of other investigators. Influence of the sample splitting on the uranium analysis was discussed in the light of the analytical results obtained.(author)

  17. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    International Nuclear Information System (INIS)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H.

    2005-12-01

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here

  18. Separation Techniques for Uranium and Plutonium at Trace Levels for the Thermal Ionization Mass Spectrometric Determination

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Han, S. H.; Kim, J. G.; Park, Y. J.; Kim, W. H

    2005-12-15

    This report describes the state of the art and the progress of the chemical separation and purification techniques required for the thermal ionization mass spectrometric determination of uranium and plutonium in environmental samples at trace or ultratrace levels. Various techniques, such as precipitation, solvent extraction, extraction chromatography, and ion exchange chromatography, for separation of uranium and plutonium were evaluated. Sample preparation methods and dissolution techniques for environmental samples were also discussed. Especially, both extraction chromatographic and anion exchange chromatographic procedures for uranium and plutonium in environmental samples, such as soil, sediment, plant, seawater, urine, and bone ash were reviewed in detail in order to propose some suitable methods for the separation and purification of uranium and plutonium from the safeguards environmental or swipe samples. A survey of the IAEA strengthened safeguards system, the clean room facility of IAEA's NWAL(Network of Analytical Laboratories), and the analytical techniques for safeguards environmental samples was also discussed here.

  19. Mass Spectrometric Calibration of Controlled Fluoroform Leak Rate Devices Technique and Uncertainty Analysis

    CERN Document Server

    Balsley, S D; Laduca, C A

    2003-01-01

    Controlled leak rate devices of fluoroform on the order of 10 sup - sup 8 atm centre dot cc sec sup - sup 1 at 25 C are used to calibrate QC-1 War Reserve neutron tube exhaust stations for leak detection sensitivity. Close-out calibration of these tritium-contaminated devices is provided by the Gas Dynamics and Mass Spectrometry Laboratory, Organization 14406, which is a tritium analytical facility. The mass spectrometric technique used for the measurement is discussed, as is the first principals calculation (pressure, volume, temperature and time). The uncertainty of the measurement is largely driven by contributing factors in the determination of P, V and T. The expanded uncertainty of the leak rate measurement is shown to be 4.42%, with a coverage factor of 3 (k=3).

  20. A comparative study of carbocyanine dyes measured with TOF-SIMS and other mass spectrometric techniques

    International Nuclear Information System (INIS)

    Adriaensen, L.; Vangaever, F.; Gijbels, R.

    2004-01-01

    A series of cationic, zwitterionic and anionic carbocyanine dyes have been measured with TOF-SIMS under Ga + bombardment. In contrast to the cationic dyes, which give very intense molecular ion and characteristic fragment signals in the positive mode, the anionic dyes produce only a few fragment signals of low intensity. Even in the negative mode no molecular ions of the anionic dyes are seen in the recorded spectra. Actually, none of the studied molecules produces negative SIMS spectra containing molecular information. A comparative study was made between TOF-SIMS and other mass spectrometric techniques, namely, fast atom bombardment (FAB), electro spray ionization (ESI) and matrix assisted laser desorption ionization (MALDI). The measurements show that MALDI, ESI as well as FAB all give rise to spectra containing molecular ion signals, either in the positive, in the negative or in both modes. Unlike with TOF-SIMS, this observation also applies to the anionic dyes. Characteristic fragments of the dyes are present in all the recorded spectra. However, TOF-SIMS appears to induce more fragment ions in comparison with the other techniques. ESI, for instance, produces hardly any molecular fragments. Finally, the kind of fragment ions recorded depends upon the technique used, though some signals are produced by various techniques. For these carbocyanine dyes there is no clear correlation between the mass spectra obtained with TOF-SIMS and spectra obtained with the other techniques. This points to different desorption/ionization mechanisms, and makes it difficult, in practice, to make predictions on the feasibility of TOF-SIMS, starting from results of the other MS techniques

  1. Vapor generation – atomic spectrometric techniques. Expanding frontiers through specific-species preconcentration. A review

    International Nuclear Information System (INIS)

    Gil, Raúl A.; Pacheco, Pablo H.; Cerutti, Soledad; Martinez, Luis D.

    2015-01-01

    This article reviews 120 articles found in SCOPUS and specific Journal cites corresponding to the terms ‘preconcentration’; ‘speciation’; ‘vapor generation techniques’ and ‘atomic spectrometry techniques’ in the last 5 years. - Highlights: • Recent advances in vapor generation and atomic spectrometry were reviewed. • Species-specific preconcentration strategies after and before VG were discussed. • New preconcentration and speciation analysis were evaluated within this framework. - Abstract: We review recent progress in preconcentration strategies associated to vapor generation techniques coupled to atomic spectrometric (VGT-AS) for specific chemical species detection. This discussion focuses on the central role of different preconcentration approaches, both before and after VG process. The former was based on the classical solid phase and liquid–liquid extraction procedures which, aided by automation and miniaturization strategies, have strengthened the role of VGT-AS in several research fields including environmental, clinical, and others. We then examine some of the new vapor trapping strategies (atom-trapping, hydride trapping, cryotrapping) that entail improvements in selectivity through interference elimination, but also they allow reaching ultra-low detection limits for a large number of chemical species generated in conventional VG systems, including complete separation of several species of the same element. This review covers more than 100 bibliographic references from 2009 up to date, found in SCOPUS database and in individual searches in specific journals. We finally conclude by giving some outlook on future directions of this field

  2. Vapor generation – atomic spectrometric techniques. Expanding frontiers through specific-species preconcentration. A review

    Energy Technology Data Exchange (ETDEWEB)

    Gil, Raúl A.; Pacheco, Pablo H.; Cerutti, Soledad [Área de Química Analítica, Facultad de Química Bioquímica y Farmacia, Universidad Nacional de San Luis, Ciudad de San Luis 5700 (Argentina); Instituto de Química de San Luis, INQUISAL, Centro Científico-Tecnológico de San Luis (CCT-San Luis), Consejo Nacional de Investigaciones Científicas y Universidad Nacional de San Luis, Ciudad de San Luis 5700 (Argentina); Martinez, Luis D., E-mail: ldm@unsl.edu.ar [Área de Química Analítica, Facultad de Química Bioquímica y Farmacia, Universidad Nacional de San Luis, Ciudad de San Luis 5700 (Argentina); Instituto de Química de San Luis, INQUISAL, Centro Científico-Tecnológico de San Luis (CCT-San Luis), Consejo Nacional de Investigaciones Científicas y Universidad Nacional de San Luis, Ciudad de San Luis 5700 (Argentina)

    2015-05-22

    This article reviews 120 articles found in SCOPUS and specific Journal cites corresponding to the terms ‘preconcentration’; ‘speciation’; ‘vapor generation techniques’ and ‘atomic spectrometry techniques’ in the last 5 years. - Highlights: • Recent advances in vapor generation and atomic spectrometry were reviewed. • Species-specific preconcentration strategies after and before VG were discussed. • New preconcentration and speciation analysis were evaluated within this framework. - Abstract: We review recent progress in preconcentration strategies associated to vapor generation techniques coupled to atomic spectrometric (VGT-AS) for specific chemical species detection. This discussion focuses on the central role of different preconcentration approaches, both before and after VG process. The former was based on the classical solid phase and liquid–liquid extraction procedures which, aided by automation and miniaturization strategies, have strengthened the role of VGT-AS in several research fields including environmental, clinical, and others. We then examine some of the new vapor trapping strategies (atom-trapping, hydride trapping, cryotrapping) that entail improvements in selectivity through interference elimination, but also they allow reaching ultra-low detection limits for a large number of chemical species generated in conventional VG systems, including complete separation of several species of the same element. This review covers more than 100 bibliographic references from 2009 up to date, found in SCOPUS database and in individual searches in specific journals. We finally conclude by giving some outlook on future directions of this field.

  3. Contribution to the study of 14 MeV neutron scattering by {sup 12}C using a time-of-flight spectrometer (1963); Contribution a l'etude de la diffusion des neutrons de 14 MeV par {sup 12}C, a l'aide d'un spectrometre a temps de vol (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Perrin, P [Commisariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-07-15

    Experimental measurements of 14 MeV fast neutrons scattering by {sup 12}C by time-flight spectrometer, with a 1.7 n. sec over-all resolution. The excitation of the 7.65 MeV level is observed. (author) [French] Etude experimentate de la diffusion par {sup 12}C des neutrons rapides de 14 MeV a l'aide d'un spectrometre de resolution totale de 17 n/s. Observation de l'excitation du niveau 0+ de 7,65 MeV. (auteur)

  4. Exploring Blueberry Aroma Complexity by Chromatographic and Direct-Injection Spectrometric Techniques

    Science.gov (United States)

    Farneti, Brian; Khomenko, Iuliia; Grisenti, Marcella; Ajelli, Matteo; Betta, Emanuela; Algarra, Alberto Alarcon; Cappellin, Luca; Aprea, Eugenio; Gasperi, Flavia; Biasioli, Franco; Giongo, Lara

    2017-01-01

    , for the most aldehydes, alcohols, terpenoids, and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma. PMID:28491071

  5. Exploring Blueberry Aroma Complexity by Chromatographic and Direct-Injection Spectrometric Techniques

    Directory of Open Access Journals (Sweden)

    Brian Farneti

    2017-04-01

    pull of VOCs, for the most aldehydes, alcohols, terpenoids, and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma.

  6. Exploring Blueberry Aroma Complexity by Chromatographic and Direct-Injection Spectrometric Techniques.

    Science.gov (United States)

    Farneti, Brian; Khomenko, Iuliia; Grisenti, Marcella; Ajelli, Matteo; Betta, Emanuela; Algarra, Alberto Alarcon; Cappellin, Luca; Aprea, Eugenio; Gasperi, Flavia; Biasioli, Franco; Giongo, Lara

    2017-01-01

    , and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma.

  7. Study of semi-conductor spectrometers for high counting rates. Application to the study of the reaction {sup 31}P (p, {alpha}{sub 0}): E{sub p} < 2 MeV; Etude de spectrometres a semi-conducteurs pour forts taux de comptage application a l'etude de la reaction {sup 31}P (p, {alpha}0): E{sub p} < 2 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Ligeon, E [Commissariat a l' Energie Atomique, 38 - Grenoble (France). Centre d' Etudes Nucleaires

    1967-10-01

    The study of nuclear reactions involving particles of low charge (E < 2 MeV) calls for spectrometers of high resolving power. In many experiments however, the counting rate is high because of Coulomb scattering at the target: this results in a distortion of the experimental spectra and a loss of resolving power in the detection equipment. The first part of the work is devoted to an evaluation of the resolving power obtained with silicon-detector spectrometers. A study of the elastic scattering of protons by {sup 31}P shows which are the factors limiting the resolving power. In the second part we examine the various types of spectrometer which can be used in the case of a high count-rate. We have built an apparatus which can be used for carrying out spectrometry on particles produced by nuclear reactions, for a total, count-rate of 10{sup 5} counts/sec. (author) [French] L'etude des reactions nucleaires avec particules chargees a basse energie (E < 2 MeV) exige des spectrometres de haute resolution. Cependant, dans de nombreuses experiences le taux de comptage est eleve, par suite de la diffusion coulombienne sur la cible; on observe alors une distorsion des spectres experimentaux et une perte de resolution de l'ensemble de detection. La premiere partie de ce travail est consacree a l'evaluation de la resolution obtenue avec des spectrometres utilisant des detecteurs au silicium. L'etude de la diffusion elastique des protons sur le {sup 31}P montre quels sont les facteurs qui limitent la resolution. Dans une deuxieme partie, nous etudions les differents types de spectrometres que l'on peut utiliser dans le cas d'un taux de comptage eleve. Nous avons construit un appareil qui permet de faire la spectrometrie de particules, provenant de reactions nucleaires, pour un taux de comptage total de 10{sup 5} c/s. (auteur)

  8. Study of semi-conductor spectrometers for high counting rates. Application to the study of the reaction {sup 31}P (p, {alpha}{sub 0}): E{sub p} < 2 MeV; Etude de spectrometres a semi-conducteurs pour forts taux de comptage application a l'etude de la reaction {sup 31}P (p, {alpha}0): E{sub p} < 2 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Ligeon, E. [Commissariat a l' Energie Atomique, 38 - Grenoble (France). Centre d' Etudes Nucleaires

    1967-10-01

    The study of nuclear reactions involving particles of low charge (E < 2 MeV) calls for spectrometers of high resolving power. In many experiments however, the counting rate is high because of Coulomb scattering at the target: this results in a distortion of the experimental spectra and a loss of resolving power in the detection equipment. The first part of the work is devoted to an evaluation of the resolving power obtained with silicon-detector spectrometers. A study of the elastic scattering of protons by {sup 31}P shows which are the factors limiting the resolving power. In the second part we examine the various types of spectrometer which can be used in the case of a high count-rate. We have built an apparatus which can be used for carrying out spectrometry on particles produced by nuclear reactions, for a total, count-rate of 10{sup 5} counts/sec. (author) [French] L'etude des reactions nucleaires avec particules chargees a basse energie (E < 2 MeV) exige des spectrometres de haute resolution. Cependant, dans de nombreuses experiences le taux de comptage est eleve, par suite de la diffusion coulombienne sur la cible; on observe alors une distorsion des spectres experimentaux et une perte de resolution de l'ensemble de detection. La premiere partie de ce travail est consacree a l'evaluation de la resolution obtenue avec des spectrometres utilisant des detecteurs au silicium. L'etude de la diffusion elastique des protons sur le {sup 31}P montre quels sont les facteurs qui limitent la resolution. Dans une deuxieme partie, nous etudions les differents types de spectrometres que l'on peut utiliser dans le cas d'un taux de comptage eleve. Nous avons construit un appareil qui permet de faire la spectrometrie de particules, provenant de reactions nucleaires, pour un taux de comptage total de 10{sup 5} c/s. (auteur)

  9. Laser-induced spectrometric techniques to investigate the speciation of Eu in organic media

    International Nuclear Information System (INIS)

    Couston, L.; Roudil, D.; Charbonnel, M.Ch.; Delage, J.; Flandin, J.L.; Mesmin, C.; Rivasseau, C.

    2000-01-01

    Laser-induced spectrometric techniques provide both selectivity and sensitivity. The extremely low detection limits are ideal for assessing the extraction mechanisms involved in enhanced reprocessing applications through detailed speciation studies. Although time-resolved laser-induced fluorescence spectroscopy (TRLIF) is one of the most sensitive spectroscopy techniques, with the optical spectrum and its lifetime constituting two sources of data, it is limited to a few fluorescing actinides and lanthanides. This drawback warrants the development of an additional, complementary spectroscopic system with greater sensitivity than UV-Visible-near IR absorptiometry, based on measuring the pressure wave caused by the deexcitation of non-fluorescing species. Laser-induced photoacoustic spectroscopy (LIPAS) is based on measuring the characteristics of the pressure wave emitted during non-radiative relaxation of the absorbed energy. This speciation technique should allow investigation of compounds that absorb in the UV-visible range and are present at low concentrations in solution. It provides data on the nature and concentration of the species, including its oxidation, complexation and even colloidal states. The two techniques with a common laser source OPO were recently installed at Marcoule. TRLIF speciation studies are generally based on analyzing modifications in the fluorescence spectrum following a short laser pulse. They are related to the characteristic spectral pattern and relaxation rate of each species in solution. In the particular case of fluorescent decay of trivalent Am, Cm, Sm, Eu, Tb and Dy ions, the metallic cation deexcitation constant is closely related to the number of water molecules in the primary coordination sphere. This property helps to obtain more information on the structure around the metal ion. The first study was an investigation of the complexation of Eu(III) by TEMA (N, N'-tetra-ethyl-malonamide (C 2 H 5 ) 2 NCO-CH 2 CON(C 2 H 5 ) 2 ) in

  10. Analysis of hairy root culture of Rauvolfia serpentina using direct analysis in real time mass spectrometric technique.

    Science.gov (United States)

    Madhusudanan, K P; Banerjee, Suchitra; Khanuja, Suman P S; Chattopadhyay, Sunil K

    2008-06-01

    The applicability of a new mass spectrometric technique, DART (direct analysis in real time) has been studied in the analysis of the hairy root culture of Rauvolfia serpentina. The intact hairy roots were analyzed by holding them in the gap between the DART source and the mass spectrometer for measurements. Two nitrogen-containing compounds, vomilenine and reserpine, were characterized from the analysis of the hairy roots almost instantaneously. The confirmation of the structures of the identified compounds was made through their accurate molecular formula determinations. This is the first report of the application of DART technique for the characterization of compounds that are expressed in the hairy root cultures of Rauvolfia serpentina. Moreover, this also constitutes the first report of expression of reserpine in the hairy root culture of Rauvolfia serpentina. Copyright (c) 2008 John Wiley & Sons, Ltd.

  11. Study of non-validity of mixture rule near K-absorption edges by X-ray spectrometric technique

    International Nuclear Information System (INIS)

    Sharanabasappa; Chitralekha, A.; Kerur, B.R.; Anilkumar, S.

    2012-01-01

    X-ray spectrometric technique has been described to determine the X-ray mass attenuation coefficient, μ/ρ, of X-rays employing HPGe X-ray detector and radioactive sources. The photon intensity is measured by gating the channel of the spectrometer at FWHM/photo peak. Using the technique the 'best value' values of μ/ρ were obtained for those thicknesses which lie in the transmission (T) range 0.5 ≥ T ≥ 0.02. Total attenuation cross sections for other elements and lead compounds were measured at photon energies from 17 to 88 keV to study the Bragg's additivity law near the absorption edge of the lead. The measured values of mass attenuation coefficient values are compared with theoretical values obtained using Winxcom (programme). This study suggests that measured mass attenuation coefficient values at and near absorption edges differ from the theoretical value by about 17-23%. (author)

  12. A spectrometer using semi-conductor detectors; study and applications (1963); Spectrometre utilisant les detecteurs a semi-conducteur: etudes et applications (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Roux, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The low average energy, 2.5 to 3.5 eV, required to produce one hole-electron pair in a semiconductor allows an accurate measurement of the energy of the ionizing particles. A high resolution spectrometer has been built using semiconductor detectors. The limit of resolution, due to electronics associated to the detector, to the detector itself and to the source of particles is studied here. The present practical limit of resolution of the spectrometer is 1700 elementary electric charges (full width at half maximum of a ray of a spectrum) or 6 keV in terms of energy lost by a particle in a silicon detector. The physical resolution usually obtained is 20 keV (0.33 per cent) with {alpha} particles of the {sup 212}Bi (6.087 MeV). It depends a lot of the kind of detector used. Some results, concerning the background of the detectors and limit of measurements for low energies are given. Various applications are presented: spectrometry {beta}, spectrometry {gamma} and X, spectrometry of mixtures of {alpha} radioactive elements, collection of {alpha} spectra. (author) [French] La faible energie moyenne, 2,5 a 3,5 eV, necessaire pour produire une paire electron-trou dans un semi-conducteur, permet une mesure precise de l'energie des particules ionisantes. Un spectrometre a haute resolution a ete construit utilisant des detecteurs a semi-conducteur. La limitation en resolution due a l'electronique associee au detecteur, au detecteur lui-meme et a la source de particules, est etudiee. La resolution pratique limite actuelle du spectrometre est 1700 charges electriques elementaires (largeur a mi-hauteur d'une raie de spectre) ou 6 keV exprimee en energie perdue par une particule dans un detecteur au silicium. La resolution physique couramment obtenue est de 20 keV (0,33 pour cent) pour les particules {alpha} du bismuth 212 (6,087 MeV). Elle depend beaucoup du detecteur utilise. Quelques resultats sont donnes concernant le mouvement propre des detecteurs et la limitation des

  13. Detection, characterization and quantification of salicylic acid conjugates in plant extracts by ESI tandem mass spectrometric techniques.

    Science.gov (United States)

    Pastor, Victoria; Vicent, Cristian; Cerezo, Miguel; Mauch-Mani, Brigitte; Dean, John; Flors, Victor

    2012-04-01

    An approach for the detection and characterization of SA derivatives in plant samples is presented based on liquid chromatography coupled to electrospray ionization (ESI) tandem mass spectrometric techniques. Precursor ion scan methods using an ESI triple quadrupole spectrometer for samples from plants challenged with the virulent Pseudomonas syringae pv tomato DC3000 allowed us to detect two potential SA derivatives. The criterion used to consider a potential SA derivative is based on the detection of analytes in the precursor ion scan chromatogram upon selecting m/z 137 and m/z 93 that correspond to the salicylate and its main product ion, respectively. Product ion spectra of the newly-detected analytes as well as accurate m/z determinations using an ESI Q-time-of-flight instrument were registered as means of characterization and strongly suggest that glucosylated forms of SA at the carboxylic and at the phenol functional groups are present in plant samples. The specific synthesis and subsequent chromatography of salicylic glucosyl ester (SGE) and glucosyl salicylate (SAG) standards confirmed the chemical identity of both peaks that were obtained applying different tandem mass spectrometric techniques and accurate m/z determinations. A multiple reaction monitoring method has been developed and applied to plant samples. The advantages of this LC-ESI-MS/MS methods with respect to the traditional analysis of glucosyl conjugates are also discussed. Preliminary results revealed that SA and the glucosyl conjugates are accumulated in Arabidopsis thaliana in a time dependent manner, accordingly to the up-regulation of SA-dependent defenses following P. syringae infection. This technique applied to plant hormones or fragment ions may be useful to obtain chemical family members of plant metabolites and help identify their contribution in the signaling of plant defenses. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  14. Characterization of plant polysaccharides from Dendrobium officinale by multiple chromatographic and mass spectrometric techniques.

    Science.gov (United States)

    Ma, Huiying; Zhang, Keke; Jiang, Qing; Dai, Diya; Li, Hongli; Bi, Wentao; Chen, David Da Yong

    2018-04-27

    Plant polysaccharides have numerous medicinal functions. Due to the differences in their origins, regions of production, and cultivation conditions, the quality and the functions of polysaccharides can vary significantly. They are macromolecules with large molecular weight (MW) and complex structure, and pose great challenge for the analytical technology used. Taking Dendrobium officinale (DO) from various origins and locations as model samples. In this investigation, mechanochemical extraction method was used to successfully extract polysaccharides from DO using water as solvent, the process is simple, fast (40 s) and with high yield. The MWs of the intact saccharides from calibration curve and light scattering measurement were determined and compared after separation with size exclusion chromatography (SEC). The large polysaccharide was acid hydrolyzed to oligosaccharides and the products were efficiently separated and identified using liquid chromatography coupled to a high resolution tandem mass spectrometry (LC-MS 2 ). Obvious differences were observed among LC-MS 2 chromatograms of digested products, and the chemical structures for the products were proposed based on accurate mass values. More importantly, isomeric digested carbohydrate compounds were explored and characterized. All the chromatographic and mass spectrometric results in this study provided a multi-dimensional characterization, fingerprint analysis, and molecular structure level assessment of plant polysaccharides. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Application and evaluation of the mass spectrometric isotope dilution technique in the determination of rare earths in geological materials

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de.

    1988-01-01

    Establishment of the experimental procedures employed in the rare earth element determination of geological samples by mass spectrometric isotope dilution analysis is discussed in the present work. The procedures involve preparation and calibration of the isotope tracers isotope dilution, dissolution in a teflon pressure vessel, chemical separation and isotope analysis using a fully automated Micromass VG ISOTOPES model 354 thermal ionization mass spectrometer. For the initial chemical separation of total rare earths the cationic resin was employed and HC1 and HNO 3 acids as eluents. In the second step rare earths elements were separated into individual (La, Ce and Nd) and subgroups (Sm-Eu-Gd, Yb-Er-Dy) fractions using the same cationic resin and α-HIBA as eluent. Nine elements La, Ce, Nd, Sm, Eu, Gd, Dy, Er and Yb are determined by this method in the ''United States Geological Survey'' (USGS) standard samples GSP-1, AGV-1 and G-2, with an overall precision of +- 1 to 2% and an accuracy of 5%. The concentration of rare earth element determined in the standard sample PCC-1 showed that the total analytical blanks are in submicrogram levels. The concentration of rare earth elements in the same USGS standard samples were also determined by Instrumental neutron activation analysis, neutron activation analysis with chemical separation before irradiation and inductively coupled argon plasma spectroscopy. The chemical procedures employed for these methods are the same as that used for mass spectrometric isotope dilution. Based on the results obtained, each method was evaluated pointing out their merits and defects. The study clearly showed that the chemical procedure employed for all these techniques was satisfactory. (author) [pt

  16. A review of micro-wave techniques in plasma studies; Survol des techniques micro-ondes pour l'etude des plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, T [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    The problem of the application of micro-wave techniques to the study of plasma properties is considered in this report. In section I, the author summarizes a few fundamental laws concerning the theory of waves in an ionised medium as well as measurable effects of transverse and longitudinal propagation. Section II is a rapid review of the experimental methods and of the various measurements which may be effected in very high frequency plasmas. Only recent experimental work carried out since the last U. R.S.I. Assembly is considered. Section III is devoted to micro-wave techniques developed during this period in the laboratories of the Applied Physics Service. These techniques deal with longitudinal propagation and in particular with the propagation along a right mode. Section IV is a general view of similar studies undertaken in European Research Centres working on plasma physics or controlled fusion. Section V is a contribution concerning three particular topics from the Juelich and Max Planck Institute laboratories. (author) [French] On etudie dans ce rapport le probleme de l'application des techniques micro-ondes a l'etude des proprietes d'un plasma. Dans la section I, l'auteur rappelle rapidement quelques lois fondamentales de la theorie des ondes dans un milieu ionise ainsi que les effets mesurables en propagation transversale et longitudinale. La section II est une revue rapide des methodes experimentales et des diverses mesures qui peuvent etre faites dans les plasmas aux tres hautes frequences. On ne considere seulement que les etudes experimentales recentes depuis la derniere assemblee de l'U.R.S.I. La section III est consacree aux techniques hyperfrequences developpees durant la meme periode dans les laboratoires des Services de Physique Appliquee. Ces techniques se rapportent a la propagation longitudinale et particulierement a la propagation suivant le mode droit. La section IV est un panorama de travaux similaires entrepris dans les centres europeens

  17. Development and miniaturization of a photoacoustic silicon integrated spectrometer for trace gas analysis; Etude et developpement d`un spectrometre photoacoustique integre sur silicium pour analyse de gaz

    Energy Technology Data Exchange (ETDEWEB)

    Jourdain, A.

    1998-10-29

    The study deals with the integration on silicon wafers of an infrared spectrometer for carbon dioxide measurements. Photoacoustic detection that measures a differential pressure in a cavity turns out to be the best spectroscopic technique for miniaturization and integration. The micro-system is composed of two main components: an infrared light source on a silicon nitride membrane and a component integrating a tunable optical filter, a microphone for detection and a micro-cavity. After a theoretical study of the different components, each element is realized with the microelectronic techniques such as photolithography, thin films deposits and dry and wet etching. A resin sealing of all the different elements realizes the final micro-spectrophotometer. A characterization of the components is done thanks to the realization of an electronic specific set-up. (author) 107 refs.

  18. Practical aspects of the resin bead technique for mass spectrometric sample loading

    International Nuclear Information System (INIS)

    Walker, R.L.; Pritchard, C.A.; Carter, J.A.; Smith, D.H.

    1976-07-01

    Using an anion resin bead as a loading vehicle for uranium and plutonium samples which are to be analyzed isotopically in a mass spectrometer has many advantages over conventional techniques. It is applicable to any laboratory routinely performing such analyses, but should be particularly relevant for Safeguards' purposes. Because the techniques required differ markedly from those of conventional methods, this report has been written to describe them in detail to enable those unfamiliar with the technique to master it with a minimum of trouble

  19. Analysis of local salts using x-ray spectrometric techniques | Umar ...

    African Journals Online (AJOL)

    Local salts namely: Mangul, Kantu and Manda have been analysed using x-ray diffraction and x-ray fluorescence techniques. X-ray diffraction has shown that Mangul and Kantu consist of mainly sodium chloride while Manda consists of mainly calcium potassium silicate. The major elements determined using x-ray ...

  20. Technique for mass-spectrometric determination of moisture content in fuel elements and fuel element claddings

    International Nuclear Information System (INIS)

    Kurillovich, A.N.; Pimonov, Yu.I.; Biryukov, A.S.

    1988-01-01

    A technique for mass-spectroimetric determination of moisture content in fuel elements and fuek claddings in the 2x10 -4 -1.5x10 -2 g range is developed. The relative standard deviation is 0.13. A character of moisture extraction from oxide uranium fuels in the 20-700 deg C temperature range is studied. Approximately 80% of moisture is extracted from the fuels at 300 deg C. The moisture content in fuel elements with granular uranium oxide fuels is measured. Dependence of fuel element moisture content on conditions of hot vacuum drying is shown. The technique permits to optimize the fuel element fabrication process to decrease the moisture content in them. 4 refs.; 3 figs.; 2 tabs

  1. Determination of toxic elements in beauty creams by X-ray spectrometric techniques (2001-2002)

    International Nuclear Information System (INIS)

    War-War-Myo-Aung

    2002-01-01

    This paper is carried out to examine the contents of toxic heavy metals in various kinds of beauty creams by using Energy Dispersive X-ray Fluorescence Technique (EDXRF). By applying EDXRF system, it si found that most of the beauty creams contained titanium and zinc, and some of the beauty creams contained lead, bismuth, iron and mercury. Among the heavy toxic metals, mercury is the most harmful to human's health. (author)

  2. Some techniques for studying actomyosin by electron microscopy; Quelques techniques d'etude de l'actomyosine par microscopie electronique

    Energy Technology Data Exchange (ETDEWEB)

    Herzberg, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement de Biologie

    1967-07-01

    A method has been developed for shadowing using a platinum-carbon alloy; it has been applied to the study of the interaction of actomyosin with its substrate ATP. The results obtained seem to favour the hypothesis of a dissociation of the actomyosin into its two components: actin and myosin. Pictures have been obtained showing particles resembling non-polymerized myosin but no rigorous proof of this exists. (author) [French] Une methode d'ombrage par un alliage de platine et carbone a ete mise au point et appliquee a l'etude de l'interaction de l'actomyosine et de son substrat l'ATP. Les resultats obtenus semblent pencher en faveur de la these d'une dissociation de l'actomyosine en ses deux constituants: l'actine et la myosine. Des images ont ete obtenues montrant des particules dont l'identite avec la myosine non polymerisee reste a demontrer plus rigoureusement. (auteur)

  3. Profiling of Piper betle Linn. cultivars by direct analysis in real time mass spectrometric technique.

    Science.gov (United States)

    Bajpai, Vikas; Sharma, Deepty; Kumar, Brijesh; Madhusudanan, K P

    2010-12-01

    Piper betle Linn. is a traditional plant associated with the Asian and southeast Asian cultures. Its use is also recorded in folk medicines in these regions. Several of its medicinal properties have recently been proven. Phytochemical analysis showed the presence of mainly terpenes and phenols in betel leaves. These constituents vary in the different cultivars of Piper betle. In this paper we have attempted to profile eight locally available betel cultivars using the recently developed mass spectral ionization technique of direct analysis in real time (DART). Principal component analysis has also been employed to analyze the DART MS data of these betel cultivars. The results show that the cultivars of Piper betle could be differentiated using DART MS data. Copyright © 2010 John Wiley & Sons, Ltd.

  4. Development of a technique for mass spectrometric measurement of δ18O of aqueous sulphate

    International Nuclear Information System (INIS)

    Kulkarni, U.P.; Sharma, Suman

    2003-01-01

    Application of stable isotopes of hydrogen and oxygen as tracers in hydrology for studying the origin of water is well established. δ 18 O of water molecule itself is used for identifying the source of water whereas δ 18 O of dissolved oxy anions (such as carbonate, phosphate, sulphate, nitrate and silicate) present in the same water reveal their source of origin. δ 18 O of SO 4 finds applications in identifying the origin of sulfate i.e. marine, marine evaporite or non-marine in nature and as a geothermometer in determining subsurface temperature of geothermal waters. A vacuum line of glass was fabricated to measure δ 18 O of aqueous sulfate. This paper deals with the technique and results of a trial with NBS-127, Sea water barium sulfate

  5. Characterization of spent nuclear fuels by an online combination of chromatographic and mass spectrometric techniques

    International Nuclear Information System (INIS)

    Guenther-Leopold, Ines; Wernli, Beat; Kopajtic, Zlatko

    2003-01-01

    The determination of the burn-up is one of the essential parts in post-irradiation examinations on nuclear fuel samples. In the frame of national and international research programs the analysis of the isotopic vectors of uranium, plutonium, neodymium and some other fission products and actinides was carried out in the Hot lab of the Paul Scherrer Institute in the last years by using high-performance liquid chromatography coupled online with an inductively coupled plasma quadrupole mass spectrometer. In the meantime a multicollector ICP-MS, suitable for high precision isotope ratio measurements, was installed within the Hot lab and has been used now in combination with a chromatographic separation system for the first time for burn-up determinations of nuclear fuel samples. The results of these investigations, a comparison of both methods with the classical technique for burn-up analyses (thermal ionization mass spectrometry), the advantages and limitations of the methods and the accuracy and precision of this type of analyses are presented in the paper. (author)

  6. Near infrared spectrometric technique for testing fruit quality: optimisation of regression models using genetic algorithms

    Science.gov (United States)

    Isingizwe Nturambirwe, J. Frédéric; Perold, Willem J.; Opara, Umezuruike L.

    2016-02-01

    Near infrared (NIR) spectroscopy has gained extensive use in quality evaluation. It is arguably one of the most advanced spectroscopic tools in non-destructive quality testing of food stuff, from measurement to data analysis and interpretation. NIR spectral data are interpreted through means often involving multivariate statistical analysis, sometimes associated with optimisation techniques for model improvement. The objective of this research was to explore the extent to which genetic algorithms (GA) can be used to enhance model development, for predicting fruit quality. Apple fruits were used, and NIR spectra in the range from 12000 to 4000 cm-1 were acquired on both bruised and healthy tissues, with different degrees of mechanical damage. GAs were used in combination with partial least squares regression methods to develop bruise severity prediction models, and compared to PLS models developed using the full NIR spectrum. A classification model was developed, which clearly separated bruised from unbruised apple tissue. GAs helped improve prediction models by over 10%, in comparison with full spectrum-based models, as evaluated in terms of error of prediction (Root Mean Square Error of Cross-validation). PLS models to predict internal quality, such as sugar content and acidity were developed and compared to the versions optimized by genetic algorithm. Overall, the results highlighted the potential use of GA method to improve speed and accuracy of fruit quality prediction.

  7. Chemometric profile of root extracts of Rhodiola imbricata Edgew. with hyphenated gas chromatography mass spectrometric technique.

    Directory of Open Access Journals (Sweden)

    Amol B Tayade

    Full Text Available Rhodiola imbricata Edgew. (Rose root or Arctic root or Golden root or Shrolo, belonging to the family Crassulaceae, is an important food crop and medicinal plant in the Indian trans-Himalayan cold desert. Chemometric profile of the n-hexane, chloroform, dichloroethane, ethyl acetate, methanol, and 60% ethanol root extracts of R. imbricata were performed by hyphenated gas chromatography mass spectrometry (GC/MS technique. GC/MS analysis was carried out using Thermo Finnigan PolarisQ Ion Trap GC/MS MS system comprising of an AS2000 liquid autosampler. Interpretation on mass spectrum of GC/MS was done using the NIST/EPA/NIH Mass Spectral Database, with NIST MS search program v.2.0g. Chemometric profile of root extracts revealed the presence of 63 phyto-chemotypes, among them, 1-pentacosanol; stigmast-5-en-3-ol, (3β,24S; 1-teracosanol; 1-henteracontanol; 17-pentatriacontene; 13-tetradecen-1-ol acetate; methyl tri-butyl ammonium chloride; bis(2-ethylhexyl phthalate; 7,8-dimethylbenzocyclooctene; ethyl linoleate; 3-methoxy-5-methylphenol; hexadecanoic acid; camphor; 1,3-dimethoxybenzene; thujone; 1,3-benzenediol, 5-pentadecyl; benzenemethanol, 3-hydroxy, 5-methoxy; cholest-4-ene-3,6-dione; dodecanoic acid, 3-hydroxy; octadecane, 1-chloro; ethanone, 1-(4-hydroxyphenyl; α-tocopherol; ascaridole; campesterol; 1-dotriacontane; heptadecane, 9-hexyl were found to be present in major amount. Eventually, in the present study we have found phytosterols, terpenoids, fatty acids, fatty acid esters, alkyl halides, phenols, alcohols, ethers, alkanes, and alkenes as the major group of phyto-chemotypes in the different root extracts of R. imbricata. All these compounds identified by GC/MS analysis were further investigated for their biological activities and it was found that they possess a diverse range of positive pharmacological actions. In future, isolation of individual phyto-chemotypes and subjecting them to biological activity will definitely prove fruitful

  8. Determination of long-lived radionuclides at ultratrace level using advanced mass spectrometric techniques

    International Nuclear Information System (INIS)

    Zoriy, M.

    2005-11-01

    Determination of long-lived radionuclides at sub-fg concentration level is a challenging task in analytical chemistry. Inductively coupled plasma mass spectrometry (ICP-MS) with its ability to provide the sensitive and fast multielemental analysis is one of the most suitable method for the measurements of long lived radionuclides in the trace and ultra trace concentration range. In present the Ph.D. study a variety of procedures have been developed permitting the sub fg ml-1 determination of long-lived radionuclides (e.g. U, Th, Pu) as well as 226 Ra (T 1/2 = 1600 y) and 90 Sr (T 1/2 = 28.1 y) in different samples. In order to avoid isobaric interferences, to increase the sensitivity, precision and accuracy of the methods the application of different techniques: pre-concentration of the sample, off-line separation on the crown resin, measurements under cold plasma conditions, using microconcentric nebulizers (e.g DIHEN, DS-5) or the application of LA-ICP-MS for sample introduction have been studied. The limits of detection for different radionuclides was significantly improved in comparison to the ones reported in the literature, and, depending on the method applied, was varied from 10 -15 to 10 -18 g ml -1 concentration range. In addition to the analysis of long lived radionuclides, some other elements, that can present potential interest to the analyzed sample, were measured within the framework of the present study. Laser ablation inductively coupled plasma mass spectrometry (LAICP- MS) was used to produce images of element distribution in 20μm m thin sections of human brain tissue. The sample surface was scanned (raster area ∝80 mm 2 ) with a focused laser beam (wavelength 213 nm, diameter of laser crater 50μm, and laser power density 3x10 9 W cm -2 ) in a cooled laser ablation chamber developed for these measurements. Cross sections of human brain samples - hippocampus as well as brain tissues infected and non-infected with Glioblastoma Multiforme (tumor

  9. Isotopic Determination of Nuclear Materials Using Nuclear Fission Track Registration Technique and Thermal Ionization Mass Spectrometric Technique

    International Nuclear Information System (INIS)

    Jeon, Young Sin; Pyo, Hyeong Yeol; Park, Yong Joon; Song, Kyu Seok; Kim, Won Ho; Jee, Kwang Yong

    2007-05-01

    It is very important to develope the technology for the determination of isotopic ratios of hot particles( 234 U, 235 U, 236 U etc.) detected from swipe samples of various nuclear facilities. This technology is highly competitive internationally and has to be established independently as long as our government maintains atomic energy and treats nuclear materials. In this text, sample pretreatment procedure, gamma-ray counting, alpha or fission track techniques, isotopic analysis of U and Pu, background problems and detection limits for mass determination, and their application to the real swipe sample were described with detailed procedure. This technology would contribute to the Korean economy's high growth rate as well as to superiority of government's leading research and development programs if successfully established

  10. Evaluation of radioactive environmental hazards in Area-3, Northern Palmyrides, Central Syria using airborne spectrometric gamma technique

    International Nuclear Information System (INIS)

    Asfahani, J.; Aissa, M.; Al-Hent, R.

    2016-01-01

    Airborne spectrometric gamma data are used in this paper to estimate the degree of radioactive hazard on humanity in Area-3, Northern Palmyrides, Central Syria. Exposure Rate (ER), Absorbed Dose Rate (ADR), Annual Effective Dose Rate (AEDR), and Heat Production (HP) of the eleven radiometric units included in the established lithological scored map in the study area have been computed to evaluate the radiation background influence in humans. The results obtained indicate that a human body in Area-3 is subjected to radiation hazards in the acceptable limits for long duration exposure. The highest radiogenetic heat production values in Area-3 correspond to the phosphatic locations characterized by relatively high values of uranium and thorium. - Highlights: • Degree of radioactive hazard has been estimated by using airborne spectrometric gamma data. • ER, ADR, AEDR, and HP of the eleven radiometric units have been computed. • Comparison of AEDR of Area-3 with the AEDR of Area-1. • Human body in Area-3 is subjected to radiation hazards in the acceptable limits for long duration exposure. • The highest heat production in Area-3 correspond to the phosphatic locations.

  11. Processing of data issued from {gamma} spectrometer. Application to the study of decay schemes; Traitement des informations issues d'un spectrometre {gamma}. Application a l'etude de schemas de desintegration

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, J P; Legrand, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The main purpose of the following report is the study of a generation method of {gamma} spectra corresponding to any energy, from a library of some basic spectra. Then we point out how to establish the decay scheme of a radio-nuclide, in using an accurate analysis of full-energy peaks which appear in its complex spectrum, followed by a generation of plain spectra corresponding to the energies of the different transitions, and ending with a least-squares fitting procedure of the complex spectrum. The accuracy of the process is examined comparing the calculated spectra to the ones issued from two kinds of spectrometers (Na I(Tl) and Ge(Li)). The method is then applied to the study of {sup 134}Cs and {sup 95}Zr - {sup 95}Nb. (authors) [French] Le present rapport a pour principal objet l'etude d'une methode de generation de spectres {gamma} correspondant a n'importe quelle energie, a partir d'une bibliotheque de quelques spectres de reference. On montre ensuite comment on peut etablir le schema de desintegration d'un radionucleide, a l'aide d'une analyse precise des pics d'absorption totale apparaissant dans son spectre complexe, suivie d'une generation des spectres simples correspondant aux energies des diverses transitions, et en terminant par une decomposition du spectre complexe par la methode des moindres carres. On examine la validite du procede en comparant les spectres calcules a ceux obtenus avec deux types de detecteurs (scintillateurs et semi-conducteurs). On applique alors la methode a l'etude du {sup 134}Cs et du {sup 95}Zr - {sup 95}Nb. (auteurs)

  12. Applications of prospecting geochemical techniques to the search for and to the study of uranium deposits in metropolitan France; Applications des techniques geochimiques de prospection a la recherche et a l'etude des gites uraniferes en France metropolitaine

    Energy Technology Data Exchange (ETDEWEB)

    Grimbert, Arnold

    1957-07-01

    After having recalled facts which leaded the CEA to use new geochemical techniques for the prospecting of uranium deposits through sampling and analysis of soils and waters, the author describes the organisation and methods implemented for this prospecting activity: team composition for sampling and analysis, role of each engineer and technician in the prospecting stages (preliminary study, routine prospecting, result interpretation), sampling and analysis processes. He also reports campaigns of geochemical prospecting: study of the La Chapelle Largeau deposit (objectives, geological context, preliminary study, routine prospecting, study of geochemical anomalies), tactical research on Verneix indices (study of radioactivity anomaly discovered by radio-prospecting), strategical searches in a non prospected area in the South of Avallon. The author discusses the issues of efficiency and cost price of this geochemical prospecting technique in soils and in waters. Appendices present the equipment and operation modality for soil sampling, and for soil sample preparation, and principles, equipment and products for soil analysis and for water analysis [French] A la suite des resultats satisfaisants obtenus dans la recherche de methodes de dosage adaptees au cas de l'uranium, la Direction des Recherches Minieres du Commissariat a l'Energie atomique a decide, en decembre 1954, d'utiliser, conjointement avec les methodes classiques de prospection, les techniques geochimiques pour la recherche et l'etude des gites uraniferes. Ces applications pratiques ont ete confiees a une Section de Geochimie dont l'organisation, les moyens en personnel et en materiel, ainsi que les methodes de travail, font l'objet d'un expose detaille. Quelques exemples de prospection, en France metropolitaine, montrent la nature des problemes poses (etude d'un gisement connu, recherche tactique sur des indices, recherche strategique dans une region non prospectee), les methodes utilisees pour les

  13. The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis.

    Science.gov (United States)

    Rosenberg, Erwin

    2003-06-06

    The use of mass spectrometry based on atmospheric pressure ionisation techniques (atmospheric pressure chemical ionisation, APCI, and electrospray ionisation, ESI) for speciation analysis is reviewed with emphasis on the literature published in and after 1999. This report accounts for the increasing interest that atmospheric pressure ionisation techniques, and in particular ESI, have found in the past years for qualitative and quantitative speciation analysis. In contrast to element-selective detectors, organic mass spectrometric techniques provide information on the intact metal species which can be used for the identification of unknown species (particularly with MS-MS detection) or the confirmation of the actual presence of species in a given sample. Due to the complexity of real samples, it is inevitable in all but the simplest cases to couple atmospheric pressure MS detection to a separation technique. Separation in the liquid phase (capillary electrophoresis or liquid chromatography in reversed phase, ion chromatographic or size-exclusion mode) is particularly suitable since the available techniques cover a very wide range of analyte polarities and molecular mass. Moreover, derivatisation can normally be avoided in liquid-phase separation. Particularly in complex environmental or biological samples, separation in one dimension is not sufficient for obtaining adequate resolution for all relevant species. In this case, multi-dimensional separation, based on orthogonal separation techniques, has proven successful. ESI-MS is also often used in parallel with inductively coupled plasma MS detection. This review is structured in two parts. In the first, the fundamentals of atmospheric pressure ionisation techniques are briefly reviewed. The second part of the review discusses recent applications including redox species, use of ESI-MS for structural elucidation of metal complexes, characterisation and quantification of small organometallic species with relevance to

  14. Analysis of antioxidants in insulation cladding of copper wire: a comparison of different mass spectrometric techniques (ESI-IT, MALDI-RTOF and RTOF-SIMS).

    Science.gov (United States)

    Schnöller, Johannes; Pittenauer, Ernst; Hutter, Herbert; Allmaier, Günter

    2009-12-01

    Commercial copper wire and its polymer insulation cladding was investigated for the presence of three synthetic antioxidants (ADK STAB AO412S, Irganox 1010 and Irganox MD 1024) by three different mass spectrometric techniques including electrospray ionization-ion trap-mass spectrometry (ESI-IT-MS), matrix-assisted laser desorption/ionization reflectron time-of-flight (TOF) mass spectrometry (MALDI-RTOF-MS) and reflectron TOF secondary ion mass spectrometry (RTOF-SIMS). The samples were analyzed either directly without any treatment (RTOF-SIMS) or after a simple liquid/liquid extraction step (ESI-IT-MS, MALDI-RTOF-MS and RTOF-SIMS). Direct analysis of the copper wire itself or of the insulation cladding by RTOF-SIMS allowed the detection of at least two of the three antioxidants but at rather low sensitivity as molecular radical cations and with fairly strong fragmentation (due to the highly energetic ion beam of the primary ion gun). ESI-IT- and MALDI-RTOF-MS-generated abundant protonated and/or cationized molecules (ammoniated or sodiated) from the liquid/liquid extract. Only ESI-IT-MS allowed simultaneous detection of all three analytes in the extract of insulation claddings. The latter two so-called 'soft' desorption/ionization techniques exhibited intense fragmentation only by applying low-energy collision-induced dissociation (CID) tandem MS on a multistage ion trap-instrument and high-energy CID on a tandem TOF-instrument (TOF/RTOF), respectively. Strong differences in the fragmentation behavior of the three analytes could be observed between the different CID spectra obtained from either the IT-instrument (collision energy in the very low eV range) or the TOF/RTOF-instrument (collision energy 20 keV), but both delivered important structural information. Copyright 2009 John Wiley & Sons, Ltd.

  15. The leakage problem in vacuum system. Realization of a mass spectrometer detecting leaks; Le probleme des fuites en technique du vide. Realisation d'un spectrometre de masse detecteur de fuite

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1954-11-15

    In the first part of this paper we consider the problem of leaks in vacuum systems, and their detection. We consider in particular the method of detection by means of a helium spectrometer. The second part deals with the experimental set p. The analyser and the ion source have been studied in great detail, and we have also discussed the technological and mechanical aspects of the apparatus and its performances. (author) [French] Dans la premiere partie de ce travail, nous traitons le probleme des fuites en technique du vide et leur detection en general. La methode de detection par spectrometre a helium y est envisagee plus particulierement. La deuxieme partie de l'article est consacree a la realisation du spectrometre. Le tube analyseur et la source d'ions y sont etudies en detail. Nous exposons de meme les conceptions technologiques et mecaniques de l'appareil ainsi que ses performances. (auteur)

  16. Determination of trace elements in various kinds of bean by X-ray spectrometric techniques (1995-96)

    International Nuclear Information System (INIS)

    U Tin Maung Kyi; U Wai Zin Oo

    2001-01-01

    Various kinds of bean such as Peanut, Gram Whole, Black Eye Bean, Small Red Bean, Lab Lab Bean, Green Mung Bean, Filed Pea, Seasame Seed, Sultani, Maize, Butter Bean, Dolichos Lab Lab, Toor Whole, Small Yellow Bean, Cow Pea have been collected and analysed by EDXRF analysis for trace elements. The measurement system consists of a Cd-109 annual excitation source, a Si (Li) detector, H V power supply, a spectrometry amplifier, a multichannel analyser and a personal computer. The samples were prepared as pressed pellets and measured by Emission Transmission Technique. The accuracy was determined by analysing standard reference material, SOIL-7 form IAEA. (author)

  17. Surfactant sodium lauryl sulfate enhances skin vaccination: molecular characterization via a novel technique using ultrafiltration capillaries and mass spectrometric proteomics.

    Science.gov (United States)

    Huang, Chun-Ming; Wang, Chao-Cheng; Kawai, Mikako; Barnes, Stephen; Elmets, Craig A

    2006-03-01

    The skin is a highly accessible organ and thus provides an attractive immune environment for cost-effective, simple, and needle-free delivery of vaccines and immunomodulators. In this study, we pretreated mouse skin with an anionic surfactant, sodium lauryl sulfate (SLS), for a short period of time (10 min) followed by epicutaneous vaccination with hen egg lysozyme antigen. We demonstrated for the first time that pretreatment of skin with surfactant SLS significantly enhances the production of antibody to hen egg lysozyme. Short term pretreatment with SLS disorganized the stratum corneum, extracted partial lamellar lipids, induced the maturation of Langerhans cells, and did not result in epidermis thickening. To reveal the mechanism underlying these changes, particularly at the molecular level, we used a novel proteomic technique using ultrafiltration capillaries and mass spectrometry to identify in vivo proteins/peptides secreted in the SLS-pretreated skin. Two secretory proteins, named as calcium-binding protein S100A9 and thymosin beta4, were identified by this novel technique. These two proteins thus may provide new insight into the enhancing effect of surfactants on skin vaccination.

  18. Application of the spectrometric and radiochemical techniques in analyzing environmental samples from the Bulgarian Black Sea region

    International Nuclear Information System (INIS)

    Veleva, B.S.; Mungov, G.; Galabov, N.; Kolarova, M.; Guenchev, T.

    1999-01-01

    Development of the appropriate methods and techniques for marine and atmospheric radioactivity measurements in the NIMH-BAS during the last 5 years is presented. Approaches for pre-concentration of the radionuclides from the atmosphere and sea water samples followed with reliable radiochemical methods for radionuclides separation and low level counting are discussed. Dissolved radiocesium concentrations measured in a period of time starting in 1993 show some decrease with years and spatial variations probably due to the hydrophysical features of the sampling sides - the lower measured concentrations during 1995 and 1998 correspond to the lower salinity. Application of the radiochemical separation of Plutonium, Thorium, 90 Sr and Americium on the samples from the Bulgarian Black Sea coastal region is reported. (author)

  19. Folds and Etudes

    Science.gov (United States)

    Bean, Robert

    2007-01-01

    In this article, the author talks about "Folds" and "Etudes" which are images derived from anonymous typing exercises that he found in a used copy of "Touch Typing Made Simple". "Etudes" refers to the musical tradition of studies for a solo instrument, which is a typewriter. Typing exercises are repetitive attempts to type words and phrases…

  20. Identification of organic sulfur compounds in coal bitumen obtained by different extraction techniques using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Maria Elisabete; Cappelli Fontanive, Fernando; Bastos Caramao, Elina; Alcaraz Zini, Claudia [Universidade Federal do Rio Grande do Sul, Instituto de Quimica, Porto Alegre, RS (Brazil); Oliveira, Jose Vladimir de [URI, Universidade Regional Integrada do Alto Uruguai e das Missoes, Erechim, RS (Brazil)

    2011-11-15

    The determination of organic sulfur compounds (OSC) in coal is of great interest. Technically and operationally these compounds are not easily removed and promote corrosion of equipment. Environmentally, the burning of sulfur compounds leads to the emission of SO{sub x} gases, which are major contributors to acid rain. Health-wise, it is well known that these compounds have mutagenic and carcinogenic properties. Bitumen can be extracted from coal by different techniques, and use of gas chromatography coupled to mass spectrometric detection enables identification of compounds present in coal extracts. The OSC from three different bitumens were tentatively identified by use of three different extraction techniques: accelerated solvent extraction (ASE), ultrasonic extraction (UE), and supercritical-fluid extraction (SFE). Results obtained from one-dimensional gas chromatography (1D GC) coupled to quadrupole mass spectrometric detection (GC-qMS) and from two-dimensional gas chromatography with time-of-flight mass spectrometric detection (GC x GC-TOFMS) were compared. By use of 2D GC, a greater number of OSC were found in ASE bitumen than in SFE and UE bitumens. No OSC were identified with 1D GC-qMS, although some benzothiophenes and dibenzothiophenes were detected by use of EIM and SIM modes. GC x GC-TOFMS applied to investigation of OSC in bitumens resulted in analytical improvement, as more OSC classes and compounds were identified (thiols, sulfides, thiophenes, naphthothiophenes, benzothiophenes, and benzonaphthothiophenes). The roof-tile effect was observed for OSC and PAH in all bitumens. Several co-elutions among analytes and with matrix interferents were solved by use of GC x GC. (orig.)

  1. Trigger system study of the dimuon spectrometer in the ALICE experiment at CERN-LHC; Etude du systeme de declenchement du spectrometre dimuons de l'experience alice au Cern-LHC

    Energy Technology Data Exchange (ETDEWEB)

    Roig, O

    1999-12-01

    This work is a contribution to the study of nucleus-nucleus collisions at the LHC with ALICE. The aim of this experiment is to search for a new phase of matter, the quark-gluon plasma (QGP). The dimuon forward spectrometer should measure one of the most promising probes of the QGP, the production of heavy quark vector mesons (J/{psi}, {gamma}, {gamma}', {gamma}'') through their muonic decays. The dimuon trigger selects the interesting events performing a cut on the transverse momentum of the tracks. The trigger decision is taken by a dedicated electronics using RPC (''Resistive Plate Chambers'') detector information. We have made our own R and D program on the RPC detector with various beam tests. We show the performances obtained during these tests of a low resistivity RPC operating in streamer mode. The ALICE requirements concerning the rate capability, the cluster size and the time resolution are fulfilled. We have optimised the trigger with simulations which include a complete description of the read-out planes and the trigger logic (algorithm). In particular, a technique of clustering is proposed and validated. A method called ''Ds reduction'' is introduced in order to limit the effects of combinatorial background on the trigger rates. The efficiencies and the trigger rates are calculated for Pb-Pb, Ca-Ca, p-p collisions at the LHC. Other more sophisticated cuts, on the invariant mass for example, using again the RPC information have been simulated but have not shown significant improvements of the trigger rates. (author)

  2. Study and construction of a {beta}-spectrometer of uniform axial magnetic field fitted with a {beta}-{gamma} coincidence selector. Study of the {beta} spectra of {sup 32}P, {sup 203}Hg, {sup 198}Au. Measurement of the conversion coefficients of {sup 203}Ti and of {sup 198}Hg; Etude et realisation d'un spectrometre-{beta} a champ magnetique axial uniforme, muni d'un selecteur de coincidence {beta}-{gamma}. Etude des spectres {beta} du {sup 32}p, {sup 203}Hg, {sup 198}Au. Mesure des coefficients de conversion du {sup 203}Ti et du {sup 198}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Parsignault, D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    various elements of the matrix. (author) [French] Dans une premiere partie est rappele le principe du spectrometre beta a champ axial uniforme en employant systematiquement la notion de caustique. L'appareil est decrit et ses proprietes comparees a celles deduites du calcul des trajectoires. Les detecteurs des rayons beta et des rayons gamma et le dispositif de selection des co cidences avec une resolution 2 {tau} de 5 nanosecondes sont egalement presentes. Dans une seconde partie, le spectrometre est employe a l'etude de corps de reference et on confirme les resultats obtenus avec la meilleure precision. Le spectre beta du {sup 60}Co a la forme statistique avec une precision de 1 pour cent, l'energie maximale E{sub 0} est de 316,5 {+-} 1,5 keV. Celui de la transition 7/2 + {yields} 11/2 du {sup 137}Cs possede la forme unique, une fois interdite. E{sub 0} = 522 {+-} 3 keV. Coefficients de conversion {alpha}{sub k} = 96 {+-} 1 X 10{sup -3} {alpha}L + M + N 20,9 {+-} 0,5 X 10{sup -3}. Les deux spectres beta du {sup 59}Fe, separes par coincidence avec le gamma ont la forme statistique E{sub 0} = 462 {+-} 2 keV (55,1 + 0,3 pour cent) et E{sub 1} = 275 {+-} 4 keV (44,9 {+-} 0,3 pour cent). On se propose ensuite d'examiner si la regle de selection l se manifeste dans la forme du spectre beta du phosphore 32. On constate, en effet, qu'elle s'ecarte de la forme statistique et on determine son coefficient de forme. L'interpretation theorique exige l'emploi de meilleures approximations que celles habituellement employees et elle n'est pas unique. Cette etude permet egalement de mettre en evidence la legere proportion de {sup 33}P que contient la source. L'etude du spectre beta de {sup 203}Hg suivi du gamma de 279 keV a pour but de determiner les coefficients de conversion. Le spectre interieur de l'or 198 n'a pas non plus la forme statistique. Le coefficient de forme est determine ainsi que les coefficients de conversion qui presentent un leger desaccord avec ceux calcules par Rose

  3. Study and construction of a {beta}-spectrometer of uniform axial magnetic field fitted with a {beta}-{gamma} coincidence selector. Study of the {beta} spectra of {sup 32}P, {sup 203}Hg, {sup 198}Au. Measurement of the conversion coefficients of {sup 203}Ti and of {sup 198}Hg; Etude et realisation d'un spectrometre-{beta} a champ magnetique axial uniforme, muni d'un selecteur de coincidence {beta}-{gamma}. Etude des spectres {beta} du {sup 32}p, {sup 203}Hg, {sup 198}Au. Mesure des coefficients de conversion du {sup 203}Ti et du {sup 198}Hg

    Energy Technology Data Exchange (ETDEWEB)

    Parsignault, D. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-06-01

    various elements of the matrix. (author) [French] Dans une premiere partie est rappele le principe du spectrometre beta a champ axial uniforme en employant systematiquement la notion de caustique. L'appareil est decrit et ses proprietes comparees a celles deduites du calcul des trajectoires. Les detecteurs des rayons beta et des rayons gamma et le dispositif de selection des co cidences avec une resolution 2 {tau} de 5 nanosecondes sont egalement presentes. Dans une seconde partie, le spectrometre est employe a l'etude de corps de reference et on confirme les resultats obtenus avec la meilleure precision. Le spectre beta du {sup 60}Co a la forme statistique avec une precision de 1 pour cent, l'energie maximale E{sub 0} est de 316,5 {+-} 1,5 keV. Celui de la transition 7/2 + {yields} 11/2 du {sup 137}Cs possede la forme unique, une fois interdite. E{sub 0} = 522 {+-} 3 keV. Coefficients de conversion {alpha}{sub k} = 96 {+-} 1 X 10{sup -3} {alpha}L + M + N 20,9 {+-} 0,5 X 10{sup -3}. Les deux spectres beta du {sup 59}Fe, separes par coincidence avec le gamma ont la forme statistique E{sub 0} = 462 {+-} 2 keV (55,1 + 0,3 pour cent) et E{sub 1} = 275 {+-} 4 keV (44,9 {+-} 0,3 pour cent). On se propose ensuite d'examiner si la regle de selection l se manifeste dans la forme du spectre beta du phosphore 32. On constate, en effet, qu'elle s'ecarte de la forme statistique et on determine son coefficient de forme. L'interpretation theorique exige l'emploi de meilleures approximations que celles habituellement employees et elle n'est pas unique. Cette etude permet egalement de mettre en evidence la legere proportion de {sup 33}P que contient la source. L'etude du spectre beta de {sup 203}Hg suivi du gamma de 279 keV a pour but de determiner les coefficients de conversion. Le spectre interieur de l'or 198 n'a pas non plus la forme statistique. Le coefficient de forme est determine ainsi que les coefficients de conversion

  4. Marine gamma spectrometric survey

    International Nuclear Information System (INIS)

    Kostoglodov, V.V.

    1979-01-01

    Presented are theoretical problems physical and geochemical prerequisites and possibilities of practical application of the method of continuous submarine gamma-spectrometric survey and radiometric survey destined for rapid study of the surface layer of marine sediments. Shown is high efficiency and advantages of this method in comparison with traditional and widely spread in marine geology methods of bottom sediments investigation

  5. Mobile spectrometric laboratory

    International Nuclear Information System (INIS)

    Isajenko, K.A.; Lipinski, P.

    2002-01-01

    The article presents the Mobile Spectrometric Laboratory used by Central Laboratory for Radiological Protection since year 2000. The equipment installed in the Mobile Laboratory and its uses is described. The results of international exercises and intercalibrations, in which the Laboratory participated are presented. (author)

  6. EXIGENCES TECHNIQUES DANS LA CONSTRUCTION ET REGLEMENTATION : ETUDE D’UN EXEMPLE DE LOGEMENT COLLECTIF A AIN-SMARA (ALGERIE

    Directory of Open Access Journals (Sweden)

    B BENRACHI

    2002-12-01

    Full Text Available La construction d’un édifice de qualité standard et répondant aux exigences techniques est   obtenue grâce au développement du savoir-faire et au respect des règles de l’art et de la réglementation en vigueur.  Une étude détaillée sur les  exigences techniques et le respect de la réglementation  d’un logement en collectif  nouvellement construit et inhabité à Ain-Smara, nous a montré  qu’il y a une satisfaction pour certaines d'entre-elles et une non-conformité pour d’autres. Il en résulte que le degré de satisfaction de ce logement est inférieur à celui recommandé dans le cadre de la réglementation, ce qui diminue sa qualité par rapport au standard exigé.

  7. Studies on solid-state physics carried out with the Saclay reactor (1962); Etudes de physique du solide realisees a la pile de Saclay (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Herpin, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    This paper deals only with solid-state physics experiments carried out on outgoing beams: rather than giving a general review of the work performed, if refers to only a few of the most important studies or those nearest completion. These are being made with the experimental beams of the two Saclay reactors EL-2, with a central flux of 10{sup 13} n/cm{sup 2}, and - since 1958 - EL-3, whose central flux is equal ta 10{sup 14} n/cm{sup 2}. The experiments are being carried out by two separate groups of physicists, employing different techniques, namely neutron diffraction using a crystal spectrometer, and inelastic scattering using a time-of-flight spectrometer. (author) [French] Cet expose ne relate que des experiences de physique du solide faites sur des faisceaux sortis; plutot que de donner une revue de l'ensemble des travaux effectues, on ne cite que quelques etudes que l'on peut considerer comme plus essentielles ou mieux achevees. On utilise les faisceaux experimentaux des deux piles de Saclay, EL-2 dont le flux au centre est de 10{sup 13}n/cm{sup 2} et, depuis 1958, EL-3 pour laquelle il est egal a 10{sup 14} n/cm{sup 2}. Les experiences sont realisees par deux groupes de physiciens distincts, employant des techniques differentes, la diffraction des neutrons qui utilise un spectrometre a cristal, et la diffusion inelastique avec un spectrometre a temps de vol. (auteur)

  8. Emission spectrometric isotope analyzer

    International Nuclear Information System (INIS)

    Mauersberger, K.; Meier, G.; Nitschke, W.; Rose, W.; Schmidt, G.; Rahm, N.; Andrae, G.; Krieg, D.; Kuefner, W.; Tamme, G.; Wichlacz, D.

    1982-01-01

    An emission spectrometric isotope analyzer has been designed for determining relative abundances of stable isotopes in gaseous samples in discharge tubes, in liquid samples, and in flowing gaseous samples. It consists of a high-frequency generator, a device for defined positioning of discharge tubes, a grating monochromator with oscillating slit and signal converter, signal generator, window discriminator, AND connection, read-out display, oscillograph, gas dosing device and chemical conversion system with carrier gas source and vacuum pump

  9. Study of heterogeneous multiplying and non-multiplying media by the neutron pulsed source technique; Etude des milieux heterogenes multiplicateurs et non-multiplicateurs par la technique de la source pulsee de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Deniz, V [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-06-01

    The pulsed neutron technique consists essentially in sending in the medium to be studied a short neutron pulse and in determining the asymptotic decay constant of the generated population. The variation of the decay constant as a function of the size of the medium allows the medium characteristics to be defined. This technique has been largely developed these last years and has been applied as well to moderator as to multiplying media, in most cases homogeneous ones. We considered of interest of apply this technique to lattices, to see if useful informations could be collected for lattice calculations. We present here a general theoretical study of the problem, and results and interpretation of a series of experiments made on graphite lattices. There is a good agreement for non-multiplying media. In the case of multiplying media, it is shown that the age value used until now in graphite lattices calculations is over-estimated by about 10 per cent. [French] La technique de la pulsation neutronique consiste essentiellement a envoyer dans le milieu a etudier une courte bouffee de neutrons et a determiner la constante de decroissance asymptotique de la population engendree. La variation de cette constante de decroissance en fonction des dimensions du milieu permet de determiner ses caracteristiques. Cette technique a connu ces dernieres annees un grand essor et a ete appliquee a des moderateurs et des milieux multiplicateurs. Il s'agissait dans la plupart des cas de milieux homogenes. Il nous a semble interessant de l'utiliser dans le cas des reseaux, afin de voir si ces experiences peuvent fournir des renseignements utiles aux calculs. Nous presentons ici une etude theorique generale du probleme, ainsi que les resultats et l'interpretation d'une serie d'experiences faites sur des reseaux a graphite. L'accord est bon dans le cas des reseaux non-multiplicateurs. Dans le cas des reseaux multiplicateurs, on montre que la valeur de l'age utilisee jusqu'ici dans les calculs

  10. Study of superconductors with high critical temperature by using the vibrating blade technique: anelastic properties, vortices dynamics; Etude des supraconducteurs a haute temperature critique par la technique de la lame vibrante: - proprietes anelastiques, - dynamique des vortex

    Energy Technology Data Exchange (ETDEWEB)

    De Brion, Sophie

    1991-10-04

    This research thesis reports the application of the vibrating blade technique to the study of high critical temperature superconductors, first for the anelastic properties, and then for vortices dynamics. As far as the study of anelastic properties is concerned, the author reports the measurement of dissipation and of Young modulus, between 4 K and 300 K and at about 1 khz, in YbaCuO ceramics with various oxygen content. A detailed study of the tetragonal phase reveals the existence of a single relaxation process, the magnitude of which depends on the compound oxygen content and on its thermal treatment. In the second part, the author reports the measurement, under magnetic field and within a temperature range lower than the superconducting critical temperature, of a YbaCuO crystal with two different oxygen concentrations. At low temperature, the author studies the contribution of vortices trapped in an irreversible state. At high temperature, this contribution disappears and thus defines an irreversibility line beyond which vortices are in a reversible regime. This line is studied for different magnetic field orientations with respect to CuO planes. It is interpreted in terms of de-trapping thermally activated by vortices [French] La technique de la lame vibrante a ete appliquee a l'etude des supraconducteurs a haute temperature critique, pour leurs proprietes anelastiques d'abord, pour la dynamique des vortex ensuite. Dans la gamme de temperature 4 K - 300 K, nous avons mesure la dissipation et le module d'Young, a une frequence de 1 kHz environ, dans des ceramiques YBaCuO (phase 123) de differentes teneurs en oxygene (variant de O{sub 6} a O{sub 7}). Nous avons observe plusieurs pics de dissipation. Une etude detaillee de la phase tetragonale (de O{sub 6} a O{sub 6,4}) a mis en evidence un seul processus de relaxation, active thermiquement avec une energie de 0,1 eV et dont l'ampleur depend de la teneur en oxygene du compose et de son traitement thermique. Cette

  11. The study of hard microporous material using the ultrafine section technique (1961); Etude des materiaux microporeux durs par la technique des coupes ultraminces (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Magdalena, Th [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    The conventional replica techniques for the examination of surfaces or fractures with the electron microscope are unsuitable for refractories or microporous bodies. The method of cutting ultrafine sections with a diamond cutter, the sample being impregnated with methyl methacrylate, has the advantage of making possible the direct examination by transmission of the sample. (author) [French] Les techniques classiques de repliques pour l'examen de surfaces ou de fractures au microscope electronique sont difficilement applicables aux refractaires et aux microporeux. Les coupes ultraminces au couteau de diamant d'echantillons enrobes dans le methyl-methacrylate ont l'avantage de permettre l'examen direct par transmission des corps etudies. (auteur)

  12. Uranium chemistry in blood and aqueous media. Techniques of studies; Chimie de l`uranium en milieux aqueux et sanguin. Techniques d`etudes

    Energy Technology Data Exchange (ETDEWEB)

    Scapolan, St

    1996-11-01

    The object of this report in a first step, is to understand the chemistry of uranium in aqueous phase by specifying the behavior of this element in function of several parameters such PH, concentration of present species, temperature, ionic force. In a second step, investigation techniques are reviewed: X rays diffraction, potentiometric titrations, polarography, spectrophotometry, NMR of {sup 13}C, {sup 31}P, {sup 17}O, capillary electrophoresis, laser detection. The third part brings elements to understand the uranium complexation in blood medium.

  13. Kinetic ion exchange studies in ultramarines by the radioactive tracer method; Etudes cinetiques d'echanges d'ions dans les outremers par la technique des traceurs radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    May, S; Goenvec, H; Pinte, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The possibility of ion exchanges in various ultramarines has been studied in the aqueous phase. The kinetics of the exchange reactions is followed by studying the behaviour of a radioactive ion, either in the solution of the exchanging salt or in the ultramarine itself. The sodium in the make-up of the ultramarine, is found to exchange with various ions in solution. The reaction speeds appear to be governed by a diffusion process inside the grains of ultramarine. The diffusion coefficients and the activation energies are determined for the exchanges studied. Several exchange studies were carried out in an organic medium. The kinetics of ion exchange is also investigated in ultramarines from which most of the constituent sulphur has been eliminated. The results obtained in these ultramarines are compared with the exchange kinetics of the same ions in ordinary ultramarine. (author) [French] Nous avons etudie la possibilite d'echanges ioniques dans differents outremers, en phase aqueuse. L'etude cinetique des reactions d'echanges est suivie en etudiant le comportement d'ion radioactif, soit dans la solution du sel echangeant, soit dans l'outremer lui-meme. C'est le sodium de constitution de l'outremer qui s'echange avec differents ions en solution. Les vitesses de reactions semblent etre controlees par un processus de diffusion a l'interieur des grains d'outremer. Les coefficients de diffusion et les energies d'activation sont determines pour les echanges etudies. Quelques etudes sont realisees en milieu organique ou quelques echanges ont ete etudies. La cinetique d'echange d'ions est egalement etudie dans des outremers dans lesquels la majorite du soufre de constitution a ete eliminee. On compare les resultats obtenus dans ces outremers avec les cinetiques d'echanges des memes ions dans l'outremer ordinaire. (auteur)

  14. NASVD and MNF techniques and your application noise reduction in gamma-ray spectrometric data; As tecnicas NASVD e MNF e sua aplicacao na reducao de ruidos em dados gamaespectrometricos

    Energy Technology Data Exchange (ETDEWEB)

    Cavallaro, Francisco de Assis, E-mail: assisfc@yahoo.com.br, E-mail: assis@agp-la.org [Departamento de Geologia Sedimentar e Ambiental, DGSA, Instituto de Geociencias, IG, Universidade de Sao Paulo, SP (Brazil); AGPLA, AeroGeoPhysica Latinoamerica, Sao Paulo, SP (Brazil); Portugal, Rodrigo S.; Bizuti, Ariathemis M., E-mail: portugal@ige.unicamp.br, E-mail: ambizuti@ige.unicamp.br [Departamento de Geologia e Recursos Naturais, DGRN, Instituto de Geociencias, IG, Universidade Estadual de Campinas, SP (Brazil); Silva, Adalene M., E-mail: adalene@unb.br [Universidade de Brasilia (UnB), DF (Brazil). Inst. de Geociencias. Dept. de Geoquimica e Recursos Minerais (GRM)

    2009-04-15

    The radioactive decay is a random process, and the measurement precision is ruled by statistical laws. The counting ratios of the profiles are always noisy when analyzed for short periods, such as one second per measurement. Corrections made at the end of conventional processing in the airborne gamma-ray spectrometric method data are not enough to remove and minimize, or even reduce considerably, the spectrum's originated noise. Two statistic methods that act locally in collected data, in the spectrum domain, have been suggested by literature to remove such remaining noises, the Noise-Adjusted Singular Value Decomposition - NASVD and Maximum Noise Fraction - MNF. These methods produce a significantly noise reduction. In this work both methods were applied in an area comprehended by two blocks, I and II, of the airborne survey that covers the west area of Mineral Province of Tapajos between Para and Amazon states. The filtered and non-filtered data with the NASVD and MNF techniques were processed with the Lasa's parameters. The comparison of results between maps and profiles shows that both methods are valuable, since there was resolution gain in these products. (author)

  15. Comparison of different tandem mass spectrometric techniques (ESI-IT, ESI- and IP-MALDI-QRTOF and vMALDI-TOF/RTOF) for the analysis of crocins and picrocrocin from the stigmas of Crocus sativus L.

    Science.gov (United States)

    Koulakiotis, Nikolaos Stavros; Pittenauer, Ernst; Halabalaki, Maria; Tsarbopoulos, Anthony; Allmaier, Günter

    2012-03-30

    The expensive spice saffron originating from the stigmas of Crocus sativus L. and also applied in traditional Chinese medicine (TCM) constitutes a complex mixture of glycoconjugates varying not only in the aglycon structure, but also in glycosylation pattern. Therefore, various tandem mass spectrometric techniques were evaluated for their usefulness in structural elucidation. Three selected constituents of the stigmas of Crocus sativus L., trans- and cis-crocin-4 as well as picrocrocin, were isolated and purified by HPLC and finally analyzed by ESI-MS (ion trap, QqRTOF), IP-MALDI-MS (QqRTOF) and vMALDI-MS (TOF/RTOF) in combination with tandem mass spectrometry in collision energy regimes ranging from a few eV (LE) to 20 keV (HE) collisions for the first time. These data aid in structurally elucidating minor, unknown glycoconjugates originating from this plant-derived spice. LE-CID of isomeric crocins on either an ion trap with ESI or a QqRTOF-instrument with ESI or IP-MALDI as desorption/ionization technique only yielded a limited number of structurally diagnostic sodiated product ions related to the carbohydrate moiety as well as to the intact aglycon in contrast to true HE-CID. The low MW constituent picrocrocin did not yield useful LE-CID spectra, but showed a high number of structurally diagnostic product ions by HE-CID utilizing a vMALDI TOF/RTOF-instrument. The highest number of structurally diagnostic product ions allowing also determination of the carbohydrate linkage of the gentiobiose-moiety of isomeric crocins ((0,4)A(2), (3,5)A(2) product ions indicating a 1→6 carbohydrate linkage) was only achievable by HE-CID. Fragmentation of the aglycon was not observed by any collision energy regime applied. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Study of radionuclides speciation with biological molecules of interest by spectrometric techniques; Etude de la speciation des radionucleides avec les molecules d'interet biologique par approche spectrometrique

    Energy Technology Data Exchange (ETDEWEB)

    Lourenco, V

    2007-07-15

    Mechanisms of complexation and accumulation of the radionuclides at the cellular and molecular level are complex and poorly known because the studies on these subjects are scarce. Within the framework of this thesis, we studied the interactions of these cations with biological molecules of interest. We chose to focus on an actinide: uranium (VI) as well as europium as an analogue of trivalent actinides. The selected biological molecules are the phyto-chelatins: their role is to protect cells against intrusions from nonessential heavy metals (thus toxic). These proteins are likely to be implied in the mechanisms of sequestration of radionuclides in living organisms. However, their structure is complex, this is why, in order to better include/understand their reactivity, we extended our studies to lower entities which constitute them (amino acid: glycine, glutamic acid and cysteine; polypeptides: glutathione reduced and oxidized forms). In particular, we determined solution speciation (stoichiometry, structure) as well as the complexing constants associated with the formation with these species. These studies were undertaken by Time Resolved Laser induced Fluorescence (TRLIF), Electro-Spray-Mass Spectrometry (ES-MS), Nuclear Magnetic Resonance (NMR), Fourier Transform Infra-Rouge spectroscopy (FTIR) and Extended X-ray Absorption Fine Structure Spectroscopy (EXAFS).The determination of the complexation constants enabled us to conclude that the complexing capacity of these molecules with respect to radionuclides was moderate (log{sub 10}K{sub 1} {<=} 3, pH 3 or 6), the formed species are mononuclear with only one ligand molecule (1:1). The interaction is performed via oxygenated (hard) groups. The direct complexation of europium with phyto-chelatins at acidic pH was studied jointly by TRLIF and ES-MS. The complexing capacity of these molecules is much higher than that of GSH from which they result. The interaction of europium with metallothioneins is, on the contrary, lower than with phyto-chelatins. In addition to studies undertaken on synthetic solutions reproducing the 'biological' conditions (pH close to neutrality, ionic strength 0,1 mol/L, etc), tests of cellular contamination were realized. We let cells grow in culture media comprising various europium concentrations. The quantification of integrated europium (by million cells) showed that those are able to incorporate europium significantly. (author)

  17. Applying a low energy HPGe detector gamma ray spectrometric technique for the evaluation of Pu/Am ratio in biological samples.

    Science.gov (United States)

    Singh, I S; Mishra, Lokpati; Yadav, J R; Nadar, M Y; Rao, D D; Pradeepkumar, K S

    2015-10-01

    The estimation of Pu/(241)Am ratio in the biological samples is an important input for the assessment of internal dose received by the workers. The radiochemical separation of Pu isotopes and (241)Am in a sample followed by alpha spectrometry is a widely used technique for the determination of Pu/(241)Am ratio. However, this method is time consuming and many times quick estimation is required. In this work, Pu/(241)Am ratio in the biological sample was estimated with HPGe detector based measurements using gamma/X-rays emitted by these radionuclides. These results were compared with those obtained from alpha spectroscopy of sample after radiochemical analysis and found to be in good agreement. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Mass Spectrometric Study of Some Fluoroquinolone Drugs Using Electron Ionization and Chemical Ionization Techniques in Combination With Semi-Empirical Calculations

    International Nuclear Information System (INIS)

    Abd EL Kareem, M.S.M.

    2013-01-01

    A mass spectrometer of the type QMS (SSQ710) is used to record the electron ionization mass spectra of some 6-fluoroquinolones molecules, namely: Norfloxacin, Pefloxacin, Ciprofloxacin and Levofloxacin.While the chemical ionization mass spectra of these compounds are recorded using Thermo Finnigan TRACE DSQ GC/MS system.In EI mass spectra, the relative intensities for the molecular ions [M] +. of the studied compounds and the prominent fragment ions are reported and discussed. Furthermore, fragmentation patterns for the four compounds have been suggested and discussed and the most important fragmentation processes such as [M-CO 2 ] +. , [M-C 2 H 4 N] + and [M-CO 2 -C 2 H 4 N] + are investigated.On the other hand, the chemical ionization (CI) mass spectra of the compounds have been recorded using methane as the reagent gas. These spectra are discussed in terms of the structure of the compounds, with particular reference to their conventional electron ionization mass spectra. The protonated molecules [M + H] + are more relatively intense than [M] +. ions in the recorded EI mass spectra indicating higher stability in the case of [M + H] + .Also, fragmentation patterns for the four compounds have been suggested and discussed (using chemical ionization technique) and the most important fragmentation processes such as [MH-CO 2 ] +. , [MH-C 2 H 4 N] + and [MH-H 2 O] + are investigated.

  19. Spectrometric control of radionuclides production parameters

    International Nuclear Information System (INIS)

    Zhuk, I.; Potarenko, A.; Yarochevich, O.; Hluboky, N.; Kerko, P.; Bogdanov, V.; Dyatel, N.

    2006-01-01

    Full text: A radioactive preparations and sources are widely used all over the world for scientific, industrial and medical purposes. These preparations in Belarus are planned to produce by the Joint Belarussian-Russian Closed Joint Stock Company 'Isotope technologies' (CJSC IT). The company was created in 1998 by two leading scientific centers-SSI 'Joint Institute of Power and Nuclear Research-Sosny' the National Academy of Sciences of Belarus and the State Center of Science of the Russian Federation 'Scientific research institute of nuclear reactors'. One of the mainstream directions in CJSC IT activities is production of radioactive preparations for the industrial and scientific application (such as 133 Ba, 109 Cd, 63 Ni, 60 Co) and for the medical purposes (such as 19 '2Ir, 60 Co). All radioactive preparations have a good export potential and adequate to modern technical and consumer requirements. X-γ spectrometric analysis of considered radioactive sources is one of the basic methods for quality control of radioactive sources. At present, we are developing x-γ spectrometric support of purification process from contaminating radionuclides of 109 Cd -γ preparation and 63 Ni - β preparation. Work on x-γ spectrometric quality control of 133 Ba preparation is carried out. The description of the used equipment is given. Techniques of contaminating radionuclides determination (contents ∼10 - '6 from activity of the basic radionuclide) are presented. Problems of the choice of geometry of measurements of sources with activity about 10 7 -10 9 Bq and possible sources of errors are discussed. (author)

  20. NZG 201 portable spectrometric unit

    International Nuclear Information System (INIS)

    Jursa, P.; Novakova, O.; Slezak, V.

    The NZG 201 spectrometric unit is a portable single-channel processing unit supplied from the mains or a battery which allows the qualitative and quantitative measurement of different types of ionizing radiation when connected to a suitable detection unit. The circuit layout and the choice of control elements makes the spectrometric unit suitable for use with scintillation detector units. The spectrometric unit consists of a pulse amplifier, an amplitude pulse analyzer, a pulse counter, a pulse rate counter with an output for a recorder, a high voltage source and a low voltage source. The block diagram is given. All circuits are modular and are mounted on PCB's. The apparatus is built in a steel cabinet with a raised edge which protects the control elements. The linear pulse amplifier has a maximum gain of 1024, the pulse counter has a maximum capacity of 10 6 -1 imp and time resolution better than 0.5 μs. The temperature interval at which the apparatus is operational is 0 to 45 degC, its weight is 12.5 kg and dimensions 36x280x310 mm, energy range O.025 to 2.5 MeV, for 137 Cs the energy resolution is 8 to 10%. The spectrometric unit NZG 2O1 may, with regard to its parameters, number and range of control elements, be used as a universal measuring unit. (J.P.)

  1. Mass Spectrometric Analysis for Nuclear Safeguards

    International Nuclear Information System (INIS)

    Boulyga, S.

    2013-01-01

    The release of man-made radionuclides into the environment results in contamination that carries specific isotopic signatures according to the release scenarios and the previous usage of materials and facilities. In order to trace the origin of such contamination and/or to assess the potential impact on the public and environmental health, it is necessary to determine the isotopic composition and activity concentrations of radionuclides in environmental samples in an accurate and timely fashion. Mass spectrometric techniques, such as thermal ionization mass spectrometry (TIMS), secondary ion mass spectrometry (SIMS), and inductively coupled plasma mass spectrometry (ICP-MS) belong to the most powerful methods for analysis of nuclear and related samples in nuclear safeguards, forensics, and environmental monitoring. This presentation will address the potential of mass spectrometric analysis of actinides at ultra-trace concentration levels, isotopic analysis of micro-samples, age determination of nuclear materials as well as identification and quantification of elemental and isotopic signatures of nuclear samples in general. (author)

  2. Spectrometric microbiological analyzer

    Science.gov (United States)

    Schlager, Kenneth J.; Meissner, Ken E.

    1996-04-01

    Currently, there are four general approaches to microbiological analysis, i.e., the detection, identification and quantification of micro-organisms: (1) Traditional culturing and staining procedures, metabolic fermentations and visual morphological characteristics; (2) Immunological approaches employing microbe-specific antibodies; (3) Biotechnical techniques employing DNA probes and related genetic engineering methods; and (4) Physical measurement techniques based on the biophysical properties of micro-organisms. This paper describes an instrumentation development in the fourth of the above categories, physical measurement, that uses a combination of fluorometric and light scatter spectra to detect and identify micro-organisms at the species level. A major advantage of this approach is the rapid turnaround possible in medical diagnostic or water testing applications. Fluorometric spectra serve to define the biochemical characteristics of the microbe, and light scatter spectra the size and shape morphology. Together, the two spectra define a 'fingerprint' for each species of microbe for detection, identification and quantification purposes. A prototype instrument has been developed and tested under NASA sponsorship based on fluorometric spectra alone. This instrument demonstrated identification and quantification capabilities at the species level. The paper reports on test results using this instrument, and the benefits of employing a combination of fluorometric and light scatter spectra.

  3. Realisation of a {beta} spectrometer solenoidal and a double {beta} spectrometer at coincidence; Realisation d'un spectrometre {beta} solenoidal et d'un double spectrometre {beta} a coincidence

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-06-15

    {alpha}{sub K} / {alpha}{sub L} et il est particulierement designe pour la determination precise des energies des rayons {gamma} par effet photoelectrique. Le double spectrometre a coincidence a ete concu pour obtenir une bonne efficacite en coincidence: en effet, la somme des angles solides utilises d'emission {beta} et {gamma} est assez peu inferieure a 4{pi} steradians. Pour obtenir cette efficacite, on a du sacrifier un peu la resolution qui est inferieure a celle obtenue au spectrometre solenoidal pour une meme luminosite. Chacun des elements du spectrometre double peut aussi etre adapte a l'etude des correlations angulaires {beta}{gamma} et e{sup -}{gamma}. Dans cet emploi, il est superieur aux lentilles magnetiques minces utilisees jusqu'ici. Le double spectrometre permet aussi l'etude des coincidences e{sup -}e{sup -}, e{sup -}{beta} d'une facon equivalente a une double lentille; on peut egalement envisager une adaptation pour l'etude des correlations angulaires e{sup -}e{sup -}, e{sup -}{beta}. Enfin, nous avons applique les methodes d'analyse par spectrometrie simple et par spectrometrie en coincidence, a l'etude des rayonnements des radioelements suivants: {sup 76}As (26 h), {sup 122}Sb (2,8 j), {sup 124}Sb (60 j), {sup 125}Sb (2,7 ans). (M.B.)

  4. Spectrometric assembly for portable installations

    International Nuclear Information System (INIS)

    Kluger, A.; Popescu, C.

    1997-01-01

    The components of the portable spectrometric assembly are: - the detecting probe with Na I(Tl) crystal and air-tight case of industrial type; - a microcomputer; - a unit of analogical processing of the signal from the detecting probe; - a single-channel analyzer with adjustable threshold; - commands and display module; - a source of high voltage; - an electrical supply battery. The device uses the method of gamma photons detection in energetic windows. Through theoretical and experimental studies carried out during the prototype development phase, the superiority of this method has been proved as compared with the installations which make use of the classical principle of photon integral detection. The achieved prototype has a basic program enabling the setting of all working parameters (measuring time, discriminating thresholds, discriminators operating conditions, etc.). Through the included interface RS232 it is possible to transmit the data to a more powerful computer in order to continually process the results. The spectrometric assembly, realized on the basis of micro-computers, can be used in a wide range of applications: measurement of thickness and erosion of walls and tubes, measurement of level in closed containers, of soil density, etc. The adjustment for specific application is performed only through a program modification. (authors)

  5. The atomic energy course of the 'Institut National des Sciences et Techniques nucleaires' at the centre d'Etudes Nucleaires at Saclay; L'enseignement de genie atomique de l'Institut national des Sciences et Techniques nucleaires au Centre d'Etudes nucleaires de Saclay

    Energy Technology Data Exchange (ETDEWEB)

    Baissas, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    foreign students. 8- Annexe: list of courses, practical work, pile projects drawn up by the 1957 students. (author)Fren. [French] 1- Les raisons de sa creation. L'electricite de France et l'industrie interessee par le developpement de l'Energie atomique ont demande au Commissariat a l'Energie atomique de former des ingenieurs capables d'etudier des projets de piles et de diriger leur construction. 2- Recrutement et Droits d'inscription. Les demandes d'inscription ont toujours depasse les possibilites. Cette annee, les cours sont suivis par 74 eleves permanents, dont 20 etrangers, et une centaine d'auditeurs libres. Tous les elevont deja ingenieurs ou nantis de grades universitaires eleves. Droit d'inscription: 250 000 F pour les eleves, 125 000 F pour les auditeurs. 3- Organisation de l'Enseignement. II comprend deux options: physique et chimie et dans chaque option: une centaine de conferences, une trentaine de travaux pratiques, des stages dans les services, l'etude d'un projet de reacteur par un groupe de 4 ou 5 eleves. L'ensemble occupe l'annee universitaire du 1 novembre au 14 juillet. 4- Sanction. Un examen final combinant les notes de deux epreuves theoriques, des travaux pratiques, du stage, et du projet conduit a un diplome d'ingenieur en genie atomique. Il n'est pas cree en realite de nouveaux ingenieurs; une mention nouvelle est seulement ajoutee a un diplome deja acquis. Les resultats ont toujours ete excellents. Le pourcentage des echecs est tres faible. 5- Placement des Diplomes. Ils reviennent tous dans leurs industries d'origine qui ont paye leurs salaires et les droits d'inscription en se privant de leurs services pendant les neuf mois de duree des cours. 6- Creations analogues. Un cours analogue a ete cree au Centre d'Etudes Nucleaires de Grenoble. Tandis que celui de SACLAY s'adresse plus specialement aux ingenieurs deja en fonctions, celui de Grenoble est, en principe, destine aux jeunes ingenieurs sortant des ecoles. 7- Conclusion. L

  6. Contribution to the study of protein deficiency: Use of radioisotope techniques; Contribution a l'etude des etats de malnutrition proteique utilisation de méthodes isotopiques

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, J.; Colard, J.; Vis, H. L. [Université libre de Bruxelles, Brussels (Belgium); Centre d' étude de l' énergie nucléaire, Mol (Belgium)

    1970-01-15

    Research methods based on the use of radioisotopes have already been used for some time to study the physiopathogenesis of malnutritional and denutritional conditions in childhood. Two very specific aspects of malnutrition are studied primarily by means of these techniques: plasma protein metabolism proper and hydroelectrolytic disorders, which are an integral part of the physiopathogenetic picture of the disease. The authors have attempted, in so far as is possible, to define the clinical condition of children from along Lake Kivu, in the east of Kivu Province, who are suffering from protein and calorie deficiency. (author) [French] Les méthodes d'investigation à l'aide de radioisotopes ont été, depuis un certain temps déjà, utilisées pour l'étude de la physiopathogénie des états de malnutrition et de dénutrition de l'enfance. Deux aspects bien particuliers de la malnutrition sont surtout étudiés à l'aide de ces méthodes: le métabolisme propre des protéines plasmatiques et les troubles hydro-électrolytiques qui font partie intégrante du tableau physiopathogénique de l'affection. Les auteurs ont essayé de définir, le mieux possible, l'état clinique des enfants de l'est de la province du Kivu, le long du lac Kivu, souffrant de malnutrition protéo-calorique. (author)

  7. Application of radioisotope techniques to the study of endemic goitre on Idjwi Island; Utilisation de methodes radioisotopiques dans l' etude du goitre endemique de l'Ile Idjwi

    Energy Technology Data Exchange (ETDEWEB)

    Delange, F.; Thilly, C.; Pourbadc, P.; Ermans, A. M. [CEMUBAC auprès de l' IRSAC, Lwiro (Congo, The Democratic Republic of the); Université libre de Bruxelles, Brussels (Belgium)

    1970-01-15

    On a world-wide scale endemic goitre represents one of the major problems of public health inasmuch as at least 200 million people are affected by this disease. Endemic goitre is particularly prevalent in Africa. The authors have recently undertaken a study of endemic goitre on Idjwi Island (Lake Kivu). The inhabitants of this island comprise an isolated population group. The island is geographically divided into a north and south zone with only occasional contact between the populations of the two zones. The entire population of the island has been examined and three zones can be distinguished as far as the prevalence of goitre is concerned: in the north of the island the number of cases is very high (averaging 54.4% of the population), whereas it drops to 5.3% in a limited region in the south-west; in the south and south-east of the island it is somewhere between the two. Radioisotope techniques have been applied to the study of three basic public health aspects of the disease. (author) [French] Le goitre endémique constitue à l’échelle mondiale un des problèmes majeurs de la santé publique puisque 200 millions de sujets au moins sont atteints par la maladie. Les endémies goitreuses sont particulièrement importantes en Afrique. Les auteurs ont entrepris récemment l'étude de l’endémie goitreuse de l'îleIdjwi (lac Kivu). Cette île constitue un groupe isolé de population. Elle est séparée géographiquement en deux zones: nord et sud. Les contacts entre les populations de ces deux zones sont épisodiques. La totalité de la population de l’île a été examinée. Trois zones peuvent être distinguées en ce qui concerne la prévalence du goitre: dans le nord de l’île elle est très élevée (valeur moyenne 54,4% de la population); par contre elle tombe à 5,3% dans une région limitée du sud-ouest; dans le sud et le sud-est de l’île elle est intermédiaire entre les deux premières. Des méthodes radioisotopiques ont été appliquées à l

  8. Significance of Airborne Gamma-ray spectrometric data of Umm bisilla Area, central Eastern Desert, Egypt

    Energy Technology Data Exchange (ETDEWEB)

    Rabie, S I [Nuclear materials authority, Maadi, Cairo, (Egypt)

    1995-10-01

    Umm bisilla area, located in the Central Eastern Desert of Egypt, consists mainly of basement rocks. The present investigation of the airborne spectrometric data is to define the meaningful anomalies from the raw data by applying the significance factor techniques, by calculating the significant radioactive provinces. Determination of the gross structural pattern and broad variations in composition of the crystalline basement, to define the relationships between the tectonic features of the area as interpreted from aeromagnetic data, with the significant anomalies revealed from spectrometric data was carried out through the application of different magnetic techniques. Five significant uraniferous zones were detected associated with Umm Bisilla granite, amphibolite, and grey granite. The intersection of the structural lineaments interpreted from aeromagnetic data illustrated good correlation with the significant uranium anomalous zones interpreted from spectrometric data, and indicated that the concentration is structurally. 15 figs.

  9. Thermogravimetric-quadrupole mass-spectrometric analysis of geochemical samples.

    Science.gov (United States)

    Gibson, E. K., Jr.; Johnson, S. M.

    1972-01-01

    Thermogravimetric-quadrupole mass-spectrometric-analysis techniques can be used to study a wide variety of problems involving decomposition processes and identification of released volatile components. A recording vacuum thermoanalyzer has been coupled with a quadrupole mass spectrometer. The rapid scan capabilities of the quadrupole mass spectrometer are used to identify the gaseous components released. The capability of the thermogravimetric-quadrupole mass spectrometer to provide analytical data for identification of the released volatile components, for determination of their sequence of release and for correlation of thermal-decomposition studies is illustrated by an analysis of the Orgueil carbonaceous chondrite.

  10. The application study on the prospecting for gold by car-borne gamma-ray spectrometric method in northern Hebei and other areas

    International Nuclear Information System (INIS)

    Ma Zhongxiang; Liu Tengyao; Zhang Peng; Lu Shili; Zhai Yugui; Ma Yanfang

    1995-01-01

    The prospecting method for gold by car-borne gamma-ray spectrometric survey is a new geophysical and geochemical technique in the search for concealed gold deposits which can be used to effectively predict the regional gold metallogenetic potential area. The method of car-borne gamma-ray spectrometric survey was adopted and 63416 data at gamma-ray spectrometric measuring sites from rock masses (or strata) in northern Hebei and other areas (49100 km 2 ) are obtained. On the basis of the size of geological bodies, the sliding filtering technique was applied to process the gamma-ray spectrometric data from regional geological bodies and maps showing the parameter distribution characteristics were plotted (11 sheets). In accordance with the thorough on the distribution characteristics of gamma-ray spectrometric parameters that reflect the regional geological environment of gold metallogenesis, a set of gamma-ray spectrometric combination parameters in correlation with regional gold metallogenesis has been established and the characteristic information of gamma-ray spectrometric parameters has been extracted. Combined with geological information, the gold metallogenetic geological environment in the working area was studied, and two potential areas were predicted. After verification, gold mineralization was encountered in some areas. The study results show that the car-borne gamma-ray spectrometric method used for regional gold prospecting is a rapid, economical and effective one

  11. Criticality studies; Etudes de criticite

    Energy Technology Data Exchange (ETDEWEB)

    Breton, D; Lecorche, P; Clouet d' Orval, Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    Criticality studies made at the Commissariat a l'Energie atomique deal on the one hand with experiments on plutonium and uranium solutions, on the other hand with theoretical work on the development and use of computation, methods for the resolution of problems concerning the nuclear safety of chemical and metallurgical plants. I - Since 1958 the experimental studies have dealt with homogeneous media constituted by a fissile salt dissolved in light water. Developed using the reactor Proserpine, the experiments have been carried on at Saclay on the Alecto assemblies where solutions of plutonium or of 90 p.100 - enriched uranium can be made critical. The results already obtained relate to critical masses of cylindrical tanks of diameters from 20 to 50 cm. reflected in several ways (water, concrete, etc. . ) at concentrations up to 100 g/liter. Physical measurements (spectra, reactor noises) and interaction measurements complete the results. Other experiments relating to plutonium solutions were begun in 1963, at the Valduc Center. They deal with the study of critical masses of annular vessels of external diameter 50 cm and internal diameter varying from 10 to 30 cm. These vessels can be water reflected internally, externally, or both. Two of these vessels have been studied in interaction for various geometries. Slabs of various thicknesses were also studied. II - The studies thus undertaken allowed the development of methods of computation which have been tested on several experiments. Particular use has been made of the possibilities of calculations based on transport theory and on Monte Carlo methods. All these theoretical studies are applied to the design and control of industrial plants from the point of view of safety. (authors) [French] Les etudes de criticite effectuees au CEA comportent d'une part des experiences sur des solutions de plutonium et d'uranium enrichi, d'autre part des travaux theoriques portant sur la mise au point et l'exploitation de methodes

  12. Development of gallium arsenide gamma spectrometric detector

    International Nuclear Information System (INIS)

    Kobayashi, T.; Kuru, I.

    1975-03-01

    GaAs semiconductor material has been considered to be a suitable material for gamma-ray spectrometer operating at room temperature since it has a wid-band gap, larger than that of silicon and germanium. The basic objective of this work is to develop a GaAs gamma-ray spectrometric detector which could be used for gamma spectrometric measurement of uranium and plutonium in nuclear fuel safeguards. Liquid phase epitaxial techniques using iron (Fe) as dopant have been developed in making high purity GaAs crystals suitable for gamma-ray spectrometer operating at room temperature. Concentration of Fe in the epitaxial crystal was controlled by initial growth temperature. The best quality epitaxial crystal was obtained under the following conditions: starting temperature is about 800degC, the proportion of Fe to Ga solvent is 1 to 300. Carrier concentration of epitaxial crystals grown distributed in the ranges of 10 12 cm -3 to 10 14 cm -3 at room temperature. The thickness of the crystals ranged from 38 μm to 120 μm. Au-GaAs surface barrier detector was made of epitaxial crystal. Some of the detector were encapsulated in a can with a 50 μm Be window by welding a can to the detector holder. The detector with high energy resolution and good charge collecting characteristics was selected by alpha spectrometry at room temperature. Energy resolution of the detector for gamma-rays up to about 200 keV was very good at room temperature operation. The best energy resolutions taken with a GaAs detector were 3 keV (fwhm) and 3.8 keV for 241 Am 59.6 keV and 57 Co 122 keV, respectively, at room temperature. In order to study the applicability of the detector for nuclear safeguards, the measurements of 235 U gamma-ray spectrum have been carried out at room temperature. It was clarified that the gamma-ray spectrum of enriched U sample could be measured in high resolution with GaAs detector at room temperature, and that the content of 235 U in enriched U sources could be determined by

  13. Liquid chromatographic-mass spectrometric method for ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... Purpose: To develop and validate a simple, efficient and reliable Liquid chromatographic-mass spectrometric (LC-MS/MS) method for the quantitative determination of two dermatological drugs, ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  14. Mass spectrometric researches in isotope cosmochemistry

    International Nuclear Information System (INIS)

    Gopalan, K.

    1979-01-01

    Recent advances in the understanding of solar system processes, past and present, based on mass spectrometric researches on meteorites and moon samples are reviewed. The topics include the following : (1) Duration of nebular condensation, (2) Terminal stages of nucleosynthesis, (3) Planetary formation and evolution, (4) Heterogeneities in the solar nebula and (5) Solar wind composition. (auth.)

  15. The influence of the PDMS technique in the study of the induced modifications of polymers used in nuclear environment; Apport de la technique PDMS a l`etude des modifications induites dans des polymeres utilises en ambiance nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Nsouli, B [Lyon-1 Univ., 69 - Villeurbanne (France). Inst. de Physique Nucleaire

    1995-07-20

    The PDMS technique (Particle Induced Desorption Mass Spectrometry) combined with a TOF detection (Time of Flight) is the main tool used in this study of polymer degradation in nuclear environment. Ar{sup 3+} ions with a 9 MeV energy have been used to induce the secondary ion emission, and the study was devoted to two stresses typical of this type of environment. The first part of the work concerned with the structural modifications induced by gamma irradiation on ion exchange resin, used for nuclear effluents reprocessing, namely the poly(4-vinylpyridine), or P-4PV. For such a material, the negative fragment emission is particularly sensitive to structural modifications. Difficult physical measurements in such an insoluble and infusible material (IR, UV - Vis, EPR, TGA, dielectric measurements) became consistent after the degradation mechanisms were elucidated. These effects, interpreted in terms of scissions and recombinations, enabled us to explicit different modes of energy deposition, and shed light on some discrepancies between SIMS and PDMS. The second part of the study is devoted to the thermal ageing of an elastomer, used in fabrication of valve gaskets submitted to high temperatures. First of all, we studied the constituents of the polymeric material, i. e. copolymer, homo polymers, and also additives. This last component proved useful to analyze, as a superficial lubricant layer can mask the conformational rearrangements which seem to occur after few hours of thermal treatment (PE blocks are prevailing at the surface). Here too, the PDMS information is important to account for static SIMS and ESCA results, as its probed layer thickness lies in-between. (author) 187 refs.

  16. Novel atomic absorption spectrometric and rapid spectrophotometric methods for the quantitation of paracetamol in saliva: application to pharmacokinetic studies.

    Science.gov (United States)

    Issa, M M; Nejem, R M; El-Abadla, N S; Al-Kholy, M; Saleh, Akila A

    2008-01-01

    A novel atomic absorption spectrometric method and two highly sensitive spectrophotometric methods were developed for the determination of paracetamol. These techniques based on the oxidation of paracetamol by iron (III) (method I); oxidation of p-aminophenol after the hydrolysis of paracetamol (method II). Iron (II) then reacts with potassium ferricyanide to form Prussian blue color with a maximum absorbance at 700 nm. The atomic absorption method was accomplished by extracting the excess iron (III) in method II and aspirates the aqueous layer into air-acetylene flame to measure the absorbance of iron (II) at 302.1 nm. The reactions have been spectrometrically evaluated to attain optimum experimental conditions. Linear responses were exhibited over the ranges 1.0-10, 0.2-2.0 and 0.1-1.0 mug/ml for method I, method II and atomic absorption spectrometric method, respectively. A high sensitivity is recorded for the proposed methods I and II and atomic absorption spectrometric method value indicate: 0.05, 0.022 and 0.012 mug/ml, respectively. The limit of quantitation of paracetamol by method II and atomic absorption spectrometric method were 0.20 and 0.10 mug/ml. Method II and the atomic absorption spectrometric method were applied to demonstrate a pharmacokinetic study by means of salivary samples in normal volunteers who received 1.0 g paracetamol. Intra and inter-day precision did not exceed 6.9%.

  17. Mass spectrometric methods for trace analysis of metals

    International Nuclear Information System (INIS)

    Bahr, U.; Schulten, H.R.

    1981-01-01

    A brief outline is given of the principles of mass spectrometry (MS) and the fundamentals of qualitative and quantitative mass spectrometric analysis emphasizing recent developments and results. Classical methods of the analysis of solids, i.e. spark-source MS and thermal ionization MS, as well as recent methods of metal analysis are described. Focal points in this survey of recently developed techniques include secondary ion MS, laser probe MS, plasma ion source MS, gas discharge MS and field desorption MS. Here, a more detailed description is given and the merits of these emerging methods are discussed more explicitly. In particular, the results of the field desorption techniques in elemental analyses are reviewed and critically evaluated

  18. 5th colloquium on atomic spectrometric trace analysis

    International Nuclear Information System (INIS)

    Welz, B.

    1989-01-01

    This book deals with apparatus, use-oriented and theoretical aspects of trace analysis and spectroscopy. General articles are concerned with the analysis of environmentally relevant samples; a comparison of modern spectroscopic techniques, the coupling of hydride production, chromatography and spectrometry; chemical modifiers for graphite tube furnace atomic absorption spectroscopy (AAS), and possible applications of flow injection to atomic spectrometric trace analysis - one of the outstanding subjects of the colloquium. About one quarter of the 85 contributions deals with new techniques including flow injection. Other priority subjects are the theory and application of graphite tube furnace AAS, and a comparison between different dissolution methods and direct solid analysis. Medicine and toxicology, analysis of biological materials and environmentally relevant samples are in the foreground of use-oriented papers. (orig./BBR) [de

  19. Processing of gamma-ray spectrometric logs

    International Nuclear Information System (INIS)

    Umiastowski, K.; Dumesnil, P.

    1984-10-01

    CEA (Commissariat a l'Energie Atomique) has developped a gamma-ray spectrometric tool, containing an analog-to-digital converter. This new tool permits to perform very precise uranium logs (natural gamma-ray spectrometry), neutron activation logs and litho-density logs (gamma-gamma spectrometric logs). Specific processing methods were developped to treate the particular problems of down-hole gamma-ray spectrometry. Extraction of the characteristic gamma-ray peak, even if they are superposed on the background radiation of very high intensity, is possible. This processing methode enables also to obtain geological informations contained in the continuous background of the spectrum. Computer programs are written in high level language for SIRIUS (VICTOR) and APOLLO computers. Exemples of uranium and neutron activation logs treatment are presented [fr

  20. Electronic equipment for spectrometric data processing

    International Nuclear Information System (INIS)

    Antonov, L.J.; Trenev, A.M.; Todorova, E.I.; Dimitrov, V.D.

    1978-01-01

    Electronic equipment carrying out logical operations and a full set of the arithmetic operations was developed for spectrometric data processing. The flowsheet of the computing part of the device, made on the basis of a specialized integral circuit, is given. The device includes input registers, multiplexor, matrix commutator, arithmetic unit and indication unit. The equipment is rated to carry out calculations according to comparatively complex formulae in several seconds

  1. ETUDE - European Trade Union Distance Education.

    Science.gov (United States)

    Creanor, Linda; Walker, Steve

    2000-01-01

    Describes transnational distance learning activities among European trade union educators carried out as part of the European Trade Union Distance Education (ETUDE) project, supported by the European Commission. Highlights include the context of international trade union distance education; tutor training course; tutors' experiences; and…

  2. An Attempt to automate the lithological classification of rocks using geological, gamma-spectrometric and satellite image datasets

    International Nuclear Information System (INIS)

    Fouad, M. K.; Mielik, M. L.; Gharieb, A. N.

    2004-01-01

    The present study aims essentially at proving that the application of the integrated airborne gamma spectrometric and satellite image data is capable of refining the mapped surface geology, and identification of anomalous zones of radioelement content that could provide favorable exploration targets for radioactive mineralizations.The application of the appropriate statistical technique to correlate between satellite image data and gamma-spectrometric data is of great significance in this respect. Experience shows that Landsat T M data in 7 spectral bands are successfully used in such studies rather than MSS. Multivariate statistical analysis techniques are applied to airborne spectrometric and different spectral Landsat T M data. Reduction of the data from n-dimensionality, both qualitatively as color composite image, and quantitatively, as principal component analysis, is performed using some statistical control parameters. This technique shows distinct efficiency in defining areas where different lit ho facies occur. An area located at the north of the Eastern Desert of Egypt, north of Hurgada town, was chosen to test the proposed technique of integrated interpretation of data of different physical nature. The reduced data are represented and interpreted both qualitatively and quantitatively. The advantages and limitations of applying such technique to the different airborne spectrometric, and Landsat T M data are identified. (authors)

  3. Aspects of optical fibers and spectrometric sensors in chemical process and industrial environments

    International Nuclear Information System (INIS)

    Boisde, G.; Perez, J.J.

    1988-01-01

    For on-line control, the two alternatives of automatic sample transfer and in situ remote analysis are discussed. New concepts are emerging from the possibilities offered by optical fibers. Absorption in the visible, UV and IR, fluorescence and Raman spectrometric techniques are examined. The state of the art of optodes and devices in chemical process control are given, with some examples of applications in nuclear plants

  4. Sensitive emission spectrometric method for the analysis of airborne particulate matter

    International Nuclear Information System (INIS)

    Sugimae, A.

    1975-01-01

    A rapid and sensitive emission spectrometric method for the routine analysis of airborne particulate matter collected on the glass fiber filter is reported. The method is a powder--dc arc technique involving no chemical pre-enrichment procedures. The elements--Ag, BA: Be, Bi, Cd, Co, Cr, Cu, Fe, Ga, La, Mn, Ni, Pb, Sn, V, Y, Yb, and Zn--were determined. (U.S.)

  5. A measuring generator for testing spectrometric channels

    International Nuclear Information System (INIS)

    Dinh Sy Hien; Kalinkin, A.I.

    1984-01-01

    A measuring generator for testing and tuning an amplitude spectrometric channel is described. The device consists of a pseudo random pulse generator, constructed on shifters, a sawtooth wave generator and a shaper of stable amplitude pulses with exponential decay times. The device is made as CAMAC unit width modules and has the following specifications: average pulse repetition rate of pseudo random pulses is 3.1; 25; 50; 100; 200 kHz; peak amplitude of 2 Hz pulse repetition of saw tooth pulses is 6 V; peak amplitude of exponential shape pulses is 5 V. The block-diagram and basic circuits of the device are given

  6. The fast gamma spectrometric method of the Am-241 determination in Chernobyl restricted zone soils

    International Nuclear Information System (INIS)

    Gleisberg, B.; Lukachina, V.V.; Kirsenko, V.N.; Tepikin, V.E.; Rajevsky, V.S.; Libman, V.A.; Stoljarevsky, I.P.; Isajev, A.G.

    1997-01-01

    The known methods of the 241 Am contents determination in environmental objects, as a rule, is based on ion-chromatographic or extraction separation techniques. This approach reflects widespread opinion, that only the α-spectrometric analysis termination is suitable to ensure necessary sensitivity of the overall method of 241 Am actively determination. Really, the minimal detectable activity for such methods is about 0.05 Bq/kg (considering that Am is usually concentrated during separation procedure). However, because of α-spectrometry does not permit to separate the α-peaks of the 241 Am, and 238 Pu, but also in view of high requests to the α-spectrometric specimen purity, the multistage and laborious chemical procedures to separate 241 Am from plutonium radionuclides and other elements (with a thorough control of each separation stage) are needed

  7. Revue d'Information Scientifique et Technique - Vol 1, No 2 (1992)

    African Journals Online (AJOL)

    La Lexicometrie Documentaire: Contribution a l'utilisation des Techniques Documentaires comme Methodologie d'Etude en Sciences Sociales · EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Abdelkrim Abdoun ...

  8. Theoretical and experimental study of a calorimetric technique for measuring energy deposition in materials caused by complex pile irradiation; Etude theorique et experimentale d'une technique calorimetrique de mesure des depots d'energie dans les materiaux dus au rayonnement complexe de pile

    Energy Technology Data Exchange (ETDEWEB)

    Mas, P; Sciers, P; Droulers, Y [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires, 38 - Grenoble (France)

    1962-07-01

    Calorimetric methods may be used to measure gamma fluxes greater than 10{sup 6} r/h near the cores of swimming pool reactors. The theory, design, and properties of isothermal calorimeters are discussed, and experimental results obtained with two types are presented. Measurement of energy deposition in materials and the long term integration of energy depositions are other uses of these devices. Results of measurements on heat deposition in steel and water are given. Fluxes were also measured. (authors) [French] Une premiere partie traite de la theorie des calorimetres isothermes mis en oeuvre au C.K.N. Grenoble. La puissance deposee dans le calorimetre par les flux de rayonnement echauffe celui-ci. L'echauffement est mesure a l'aide d'un thermocouple. On montre que l'on a ainsi une mesure absolue de cette puissance. Une deuxieme partie traite de l'etude experimentale de: deux types d'appareils utilises: leur construction, les resultats experimentaux, leurs utilisations. Trois de celles-ci sont particulierement interessantes: - la mesure des hauts flux gamma, - la mesure du depot d'energie dans les materiaux, - l'integration pendant une longue duree des depots d'energie (un modele de calorimetre a fonctionne a ce jour 2 500 heures et a integre 9 x 10 puissance 10 rads gamma et 6 x 10 puissance 18 neutrons rapides). La troisieme partie est consacree a l'etude des qualites de l'appareil: robustesse, fidelite, precision, sensibilite, gamme de mesure. Enfin dans la derniere partie sont decrites deux applications de la methode calorimetrique a la mesure du depot d'energie dans un acier special et dans l'eau. (auteurs)

  9. Automatic device for compensating the earths, magnetic field around a {beta} spectrometer; Ensemble automatique de compensation du champ terrestre autour d'un spectrometre

    Energy Technology Data Exchange (ETDEWEB)

    Ristori, Ch [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-02-15

    This paper shows how the earth magnetic field inside a double focusing, {pi}{radical}2, iron free, beta ray spectrometer (radius 50 cm ) has been compensated. Three orthogonal magnetic fields are generated by three square coils sets. Each stabilized power supply is regulated through its own magnetometer (of the fluxgate type) and the earth field inside the spectrometer is compensated to 10{sup -4} Oe whatever the earth field or power supply oscillation could be. (author) [French] Cette etude a pour but de compenser le champ magnetique terrestre autour d'un spectrometre beta {pi}{radical}2 a double focalisation, a bobines sans fer et de rayon moyen des trajectoires de 50 cm. Le champ magnetique terrestre est compense par superposition de trois champs orthogonaux, chacun cree par un ensemble de cadres carres. Chacune de ces composantes est mesuree par un magnetometre. Cet ensemble permet de travailler en regulation de courant ou en regulation de champ. En regulation de courant, l'operation est manuelle. En regulation de champ, pour chaque groupe de cadres, l'alimentation stabilisee est asservie par son magnetometre et malgre les variations du champ terrestre ou de la tension secteur, la compensation du champ terrestre se fait toujours correctement au niveau du spectrometre, a 10{sup -4} Oe pres. (auteur)

  10. Moessbauer spectrometric data acquisition based on FPGA

    International Nuclear Information System (INIS)

    Zhang Yuan; Li Shimin; Chen Nan; Zhu Jingbo; Xia Yuanfu

    2008-01-01

    FPGA(Field Programmable Gate Array) is a programmable device with strong logical function and timing control ability. It is extremely potent in acquiring and processing timing signals. By replacing the traditional used SCM (Single-Chip Microcomputer) with FPGA, counting speed of Moessbauer spectrometric data acquisition can be improved markedly with significantly decreased size of the spectrometer. The counter, RAM and RS-232 communication of the module are developed on Altera Cyclone series chip EP1C6T144C8 with Quartus II. EP1C6T144C8 has 5980 logical units accompanied by 92160 bits of memory space. It is so powerful that all needs in data acquisition of the Moessbauer spectrometer can be perfectly satisfied while allowing modifications in functions and parameters. (authors)

  11. Mass Spectrometric Analysis of Synthetic Organic Pigments.

    Science.gov (United States)

    Sugaya, Naeko; Takahashi, Mitsuko; Sakurai, Katsumi; Tanaka, Nobuko; Okubo, Ichiro; Kawakami, Tsuyoshi

    2018-04-18

    Though synthetic organic colorants are used in various applications nowadays, there is the concern that impurities by-produced during the manufacturing and degradation products in some of these colorants are persistent organic pollutants and carcinogens. Thus, it is important to identify the synthetic organic colorants in various products, such as commercial paints, ink, cosmetics, food, textile, and plastics. Dyes, which are soluble in water and other solvents, could be analyzed by chromatographic methods. In contrast, it is difficult to analyze synthetic organic pigments by these methods because of their insolubility. This review is an overview of mass spectrometric analysis of synthetic organic pigments by various ionization methods. We highlight a recent study of textile samples by atmospheric pressure solid analysis probe MS. Furthermore, the mass spectral features of synthetic organic pigments and their separation from other components such as paint media and plasticizers are discussed.

  12. Mirion--a software package for automatic processing of mass spectrometric images.

    Science.gov (United States)

    Paschke, C; Leisner, A; Hester, A; Maass, K; Guenther, S; Bouschen, W; Spengler, B

    2013-08-01

    Mass spectrometric imaging (MSI) techniques are of growing interest for the Life Sciences. In recent years, the development of new instruments employing ion sources that are tailored for spatial scanning allowed the acquisition of large data sets. A subsequent data processing, however, is still a bottleneck in the analytical process, as a manual data interpretation is impossible within a reasonable time frame. The transformation of mass spectrometric data into spatial distribution images of detected compounds turned out to be the most appropriate method to visualize the results of such scans, as humans are able to interpret images faster and easier than plain numbers. Image generation, thus, is a time-consuming and complex yet very efficient task. The free software package "Mirion," presented in this paper, allows the handling and analysis of data sets acquired by mass spectrometry imaging. Mirion can be used for image processing of MSI data obtained from many different sources, as it uses the HUPO-PSI-based standard data format imzML, which is implemented in the proprietary software of most of the mass spectrometer companies. Different graphical representations of the recorded data are available. Furthermore, automatic calculation and overlay of mass spectrometric images promotes direct comparison of different analytes for data evaluation. The program also includes tools for image processing and image analysis.

  13. Energy dispersive X-Ray fluorescence spectrometric study of ...

    African Journals Online (AJOL)

    Energy dispersive X-Ray fluorescence spectrometric study of compositional differences in trace elements in dried Moringa oleifera leaves grown in two different agro-ecological locations in Ebonyi State, Nigeria.

  14. Gas Chromatography-Mass Spectrometric Analysis and Insecticidal ...

    African Journals Online (AJOL)

    HP

    Original Research Article. Gas Chromatography-Mass Spectrometric Analysis and ... into a natural fumigant/insecticide for the control of stored product insects. Keywords: Mallotus ..... stability as well as reduce cost. ACKNOWLEDGEMENT.

  15. Gas Chromatography-Mass Spectrometric Analysis of Nematicidal ...

    African Journals Online (AJOL)

    Gas Chromatography-Mass Spectrometric Analysis of Nematicidal Essential Oil of Valeriana ... Tropical Journal of Pharmaceutical Research ... have a potential to be developed to natural nematicides for the control of cereal cyst nematodes.

  16. Gas Chromatography-Mass Spectrometric Analysis and Insecticidal ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... apelta aerial parts was analyzed by gas chromatography/mass spectrometric (GC/MS) to determine its composition. ... into a natural fumigant/insecticide for the control of stored product insects.

  17. Instrumental performance of an etude after three methods of practice.

    Science.gov (United States)

    Vanden Ark, S

    1997-12-01

    For 80 fifth-grade students three practice conditions (mental, mental with physical simulation, and physical with singing) produced significant mean differences in instrumental performance of an etude. No significant differences were found for traditional, physical practice.

  18. Study of the texture of porous solids using a technique of {gamma} ray absorption; Application de l'absorption du rayonnement {gamma} a l'etude de la texture des solides poreux

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, M. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-01-01

    A technique, which enables us to measure locally total porosity, open porosity and pore size distribution is developed. The total porosity is calculated from the bulk density. A gamma absorption gauge is set up fitted with a Cs137 source. This enables the determination of the density by layers of carbonaceous samples in a practically automatic way. By taking adequate precautions it is possible to obtain the density with a maximum error {delta}{rho} {<=} 0,005 g/cm{sup 3}. The open porosity is evaluated by the absorption method after impregnation with bromoform. A new mercury porosimeter is developed using the absorption probe for the measurement of mercury infiltrated into the porous sample. Due to the localized character of exploration by this technique, the variations of porous texture in a heterogeneous sample can be studied. Used as a classical porosimeter, in the case of homogeneous samples, this apparatus is capable of exploring the equivalent diameters of pores between 500 {mu} and 0.14 {mu} with a maximum error {delta}P {<=} 0.002. The possibility of exploration of heterogeneous samples, with the facility of determination of porosities due to macro-pores combined with the non-limiting character of the method in the field of high pressures differentiates this apparatus from all the porosimeters of former conception. Examples of utilization of this technique in the case of graphite-gas reactions are presented. (author) [French] On a developpe une technique permettant la mesure localisee de la porosite totale, de la porosite ouverte et de la repartition de la taille de pores. La porosite totale est calculee a partir de la densite apparente. On a mis au point une jauge d'absorption du rayonnement gamma munie d'une source de Cs137. Celle-ci nous a permis de determiner la densite par couches d'echantillons cylindriques carbones d'une facon pratiquement automatique. En prenant les precautions adequates, il est possible d'obtenir la densite

  19. Study of the texture of porous solids using a technique of {gamma} ray absorption; Application de l'absorption du rayonnement {gamma} a l'etude de la texture des solides poreux

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-01-01

    A technique, which enables us to measure locally total porosity, open porosity and pore size distribution is developed. The total porosity is calculated from the bulk density. A gamma absorption gauge is set up fitted with a Cs137 source. This enables the determination of the density by layers of carbonaceous samples in a practically automatic way. By taking adequate precautions it is possible to obtain the density with a maximum error {delta}{rho} {<=} 0,005 g/cm{sup 3}. The open porosity is evaluated by the absorption method after impregnation with bromoform. A new mercury porosimeter is developed using the absorption probe for the measurement of mercury infiltrated into the porous sample. Due to the localized character of exploration by this technique, the variations of porous texture in a heterogeneous sample can be studied. Used as a classical porosimeter, in the case of homogeneous samples, this apparatus is capable of exploring the equivalent diameters of pores between 500 {mu} and 0.14 {mu} with a maximum error {delta}P {<=} 0.002. The possibility of exploration of heterogeneous samples, with the facility of determination of porosities due to macro-pores combined with the non-limiting character of the method in the field of high pressures differentiates this apparatus from all the porosimeters of former conception. Examples of utilization of this technique in the case of graphite-gas reactions are presented. (author) [French] On a developpe une technique permettant la mesure localisee de la porosite totale, de la porosite ouverte et de la repartition de la taille de pores. La porosite totale est calculee a partir de la densite apparente. On a mis au point une jauge d'absorption du rayonnement gamma munie d'une source de Cs137. Celle-ci nous a permis de determiner la densite par couches d'echantillons cylindriques carbones d'une facon pratiquement automatique. En prenant les precautions adequates, il est possible d'obtenir la densite avec une erreur maximale

  20. Alecto 2 - interaction studies; Alecto 2 - etudes d'interaction

    Energy Technology Data Exchange (ETDEWEB)

    Brunet, J P; Clouet d' Orval, Ch; Mougniot, J C; Penet, F [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    Weak interactions were experimentally studies with the tank of the critical assembly Alecto II and one, two or three bottles containing solutions of various concentrations. In particular, was studied the validity of certain classical assumptions, shielding effects, screening and semi-reflexion effects, importance of thermal coupling. The method of the 'k{sub eff}, solid angle' is shown to apply to such a system. The determination by divergence and pulsed neutron technique of the reactivity related to a millimeter of solution level affords the obtention of critical heights in terms of reactivity. (authors) [French] Une etude experimentale d'interactions faibles a ete faite entre la cuve de l'experience critique ALECTO II et une, deux ou trois bouteilles contenant des concentrations variees. On etudie, en particulier, la validite de certaines hypotheses classiques, effets d'ombre, d'ecrans, de semi-reflexion, importance du couplage thermique. On montre d'autre part que la methode du 'K{sub eff}, angle solide' peut s'appliquer a un tel systeme. La determination par divergence et neutrons pulses de la reactivite liee au millimetre de solution permet de traduire les hauteurs critiques obtenues, en terme de reactivite. (auteurs)

  1. Study of the mechanical stability of superconducting cavities and stiffening of these cavities by copper coating performed with thermal spray techniques; Etudes de la stabilite mecanique des cavites supraconductrices et de la methode de rigidification par projection thermique de cuivre

    Energy Technology Data Exchange (ETDEWEB)

    Gassot, H

    2001-12-01

    Today's research in nuclear physics and in particle physics needs high energy or high intensity accelerators; the use of superconducting cavities constitutes a very important technological advance for the design of such facilities, allowing high accelerating gradient with few dissipation. One of the major problems is the frequency shift under Lorentz forces: since the quality factor of the superconducting cavities is much higher than the external factor depending on the beam charge, their bandwidths are very narrow (several Hertz). Even very small mechanical deformations under Lorentz forces could induce a frequency shift which exceeds the bandwidth when the accelerating gradient becomes very high. The contribution of this thesis consists at first in a numerical analysis of this problem, then in a mechanical study of a new method for stiffening superconducting cavities: a copper coating over their external surface by thermal spray techniques. As it was a new experiment, the choice of the process and the optimization of the parameters have been carried out. An important part of this thesis has been dedicated to the systematic mechanical characterizations of the copper coatings since they are indispensable for the evaluation of the stiffening efficiency, some links between copper coating properties and thermal projection parameters have been established. The mechanical calculations are a prerequisite to obtain an effective reduction of mechanical deformations under Lorentz forces: they permit to localize the maximum deformations, to find the ideal position and the optimised shape of the stiffener. The methods implemented in this thesis allow to compare the different kinds of coating design and then to propose an interesting solution. Finally, an original approach concerning the frequency shift in pulsed mode has been developed recently, allowing to interpret some experimental observations. (author)

  2. In vivo dosimetry study of semi-conductors EPD-20 in total body irradiation technique; Etude de la dosimetrie in vivo par semi-conducteurs EPD-20 dans les conditions de l'irradiation corporelle totale

    Energy Technology Data Exchange (ETDEWEB)

    Besbes, M.; Kochbati, L.; Ben Abdennabi, A.; Abdessaied, S.; Salem, L.; Frikha, H.; Nasr Ben Ammar, C.; Hentati, D.; Gargouri, W.; Messai, T.; Benna, F.; Maalej, M. [Institut Salah-Azaiz, Service de radiotherapie oncologique, Tunis (Tunisia); Mahjoubi, H. [Institut superieur des technologies medicales de Tunis, Dept. de biophysique, Tunis (Tunisia); Farhat, L. [CHU Habib-Bourguiba, Service de radiotherapie oncologique, Sfax (Tunisia)

    2010-01-15

    Purpose: The objective of this work was the study of in vivo dosimetry performed in a series of 54 patients receiving total body irradiation (T.B.I.) at the Salah-Azaiz Institute of Tunis since 2004. In vivo dosimetry measurements were compared to analytically calculated doses from monitor units delivered. Patients and method: The irradiation was conducted by a linear accelerator (Clinac 1800, Varian, Palo Alto, USA) using nominal X-rays energies of 6 MV and 18 MV, depending on the thickness of the patient at the abdomen. The dose was measured by semi-conductors p-type E.P.D.-20. These diodes were calibrated in advance with an ionization chamber 'P.T.W. Farmer' type of 0.6 cm{sup 3} and were placed on the surface of plexiglas phantom in the same T.B.I. conditions. A study of dosimetric characteristics of semi-conductors E.P.D.-20 was carried out as a function of beam direction and temperature. Afterwards, we conducted a comparative analysis of doses measured using these detectors during irradiation to those calculated retrospectively from monitor units delivered to each patient conditioned by T.B.I.. Results: Experience showed that semi-conductors are sensitive to the angle of beam radiation (0-90 degrees) and the temperature (22-40 Celsius degrees). The maximum variation is respectively 5 and 7%, but in our irradiation conditions these correction factors are less than 1%. The analysis of the results of the in vivo dosimetry had shown that the ratio of the average measured doses and analytically calculated doses at the abdomen, mediastinum, right lung and head are 1.005, 1.007, 1.0135 and 1.008 with a standard deviation 'type A' respectively of 3.04, 2.37, 7.09 et 4.15%. Conclusion: In vivo dosimetry by semi-conductors is in perfect agreement with dosimetry by calculation. However, in vivo dosimetry using semiconductors is the only technique that can reflect the dose actually received instantly by the patient during T.B.I. given the many factors

  3. Etude des phenomenes dynamiques ultrarapides et des caracteristiques impulsionnelles d'emission terahertz du supraconducteur YBCO

    Science.gov (United States)

    Savard, Stephane

    Les premieres etudes d'antennes a base de supraconducteurs a haute temperature critique emettant une impulsion electromagnetique dont le contenu en frequence se situe dans le domaine terahertz remontent a 1996. Une antenne supraconductrice est formee d'un micro-pont d'une couche mince supraconductrice sur lequel un courant continu est applique. Un faisceau laser dans le visible est focalise sur le micro-pont et place le supraconducteur dans un etat hors-equilibre ou des paires sont brisees. Grace a la relaxation des quasiparticules en surplus et eventuellement de la reformation des paires supraconductrices, nous pouvons etudier la nature de la supraconductivite. L'analyse de la cinetique temporelle du champ electromagnetique emis par une telle antenne terahertz supraconductrice s'est averee utile pour decrire qualitativement les caracteristiques de celle-ci en fonction des parametres d'operation tels que le courant applique, la temperature et la puissance d'excitation. La comprehension de l'etat hors-equilibre est la cle pour comprendre le fonctionnement des antennes terahertz supraconductrices a haute temperature critique. Dans le but de comprendre ultimement cet etat hors-equilibre, nous avions besoin d'une methode et d'un modele pour extraire de facon plus systematique les proprietes intrinseques du materiau qui compose l'antenne terahertz a partir des caracteristiques d'emission de celle-ci. Nous avons developpe une procedure pour calibrer le spectrometre dans le domaine temporel en utilisant des antennes terahertz de GaAs bombarde aux protons H+ comme emetteur et detecteur. Une fois le montage calibre, nous y avons insere une antenne emettrice dipolaire de YBa 2Cu3O7-delta . Un modele avec des fonctions exponentielles de montee et de descente du signal est utilise pour lisser le spectre du champ electromagnetique de l'antenne de YBa 2Cu3O7-delta, ce qui nous permet d'extraire les proprietes intrinseques de ce dernier. Pour confirmer la validite du modele

  4. Interpretation of Spectrometric Measurements of Active Geostationary Satellites

    Science.gov (United States)

    Bedard, D.; Wade, G.

    2014-09-01

    Over 5000 visible near-infrared (VNIR) spectrometric measurements of active geostationary satellites have been collected with the National Research Council (NRC) 1.8m Plaskett telescope located at the Dominion Astrophysical Observatory (DAO) in Victoria, Canada. The objective of this ongoing experiment is to study how reflectance spectroscopy can be used to reliably identify specific material types on the surface of artificial Earth-orbiting objects. Active geostationary satellites were selected as the main subjects for this experiment since their orientation is stable and can be estimated to a high-level of confidence throughout a night of observation. Furthermore, for most geostationary satellites, there is a wide variety of sources that can provide some level of information as to their external surface composition. Notwithstanding the high number of measurements that have been collected to date, it was assumed that the experimenters would have a much greater success rate in material identification given the choice experimental subjects. To date, only the presence of aluminum has been confidently identified in some of the reflectance spectra that have been collected. Two additional material types, namely photovoltaic cells and polyimide film, the first layer of multi-layer insulation (MLI), have also been possibly identified. However uncertainties in the reduced spectral measurements prevent any definitive conclusion with respect to these materials at this time. The surprising lack of results with respect to material identification have forced the experimenters to use other data interpretation methods to characterize the spectral scattering characteristics of the studied satellites. The results from this study have already led to improvements in the ways that reflectance spectra from spacecraft are collected and analysed. Equally important, the data interpretation techniques elaborated over the course of this experiment will also serve to increase the body of

  5. Methods for studying the radioactive contamination of plants (1963); Methodes d'etude de la contamination radioactive des vegetaux (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Coulon, R; Jeanmaire, L; Michon, G [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1963-07-01

    The authors first define the doctrine which led to the devising of a method for studying the radioactive pollution of plants, based on the use of simple techniques, having the possibility of being adapted for routine work, and so devised that each stage is proceeded with only if the preceding one justifies it. For each stage a study is effected comparing the results obtained by the use of more exact techniques. The second part describes in detail the techniques used. (authors) [French] Dans une premiere partie lea auteurs definissent la doctrine qui leur a permis d'elaborer une methode d'etude de la pollution radioactive des vegetaux, basee sur l'utilisation de techniques simples, se pretant au travail de serie et concues de telle maniere que chaque etape n'est abordee que si la precedente le justifie. Chaque etape fait l'objet d'une etude qui compare les resultats a ceux obtenue par des techniques plus precises. La deuxieme partie decrit dans le detail les techniques utilisees. (auteurs)

  6. The formation of scientists and technicians at the 'Centre d'Etudes Nucleaires' at Saclay; Formation des scientifiques et des techniciens au Centre d'Etudes Nucleaires de Saclay

    Energy Technology Data Exchange (ETDEWEB)

    Debiesse, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The considerable needs in research workers and scientists which are asked by the nuclear energy obliged the Commissariat a l'Energie atomique to deal with a particular effort to increase the quantitative and qualitative formation of scientists. Most various ways have been used. 1- A National Institute of Nuclear Sciences and Nuclear Techniques was created, by a joint decree of the Prime Minister and the Minister for National Education (june 18, 1957). This Institute of Higher Teaching (250 students) indulges in the following matters: atomic engineering, quantum mechanics, theory and technic of particle accelerators, special metallurgy, radiobiology, thermic and mechanics of fluids. 2- An associated centre of the 'Conservatoire National des Arts et Metiers' waeated (200 students) for technical assistants, drawers, etc. 3- In contribution with both electronic industry and Ministry of Work, the Centre d'Etudes Nucleaires contributes to an accelerated formation of technical assistants into Professional Centres. Conclusion: Training of scientists and research workers is one of the most important activities of the Centre d'Etudes Nucleaires de Saclay. Without losing its technical efficiency, it has supplied and varied means adapted to the various purposes that we shall reach. (author)Fren. [French] Les besoins considerables actuels et previsibles en chercheurs et scientifiques necessites par l'avevement de l'energie nucleaire imposaient au Commissariat a I'Energie atomique un effort particulier pour augmenter la formation quantitative et qualitative des scientifiques. Les moyens les plus divers ont ete mis en oeuvre: 1- Creation de l'Institut National des Sciences et Techniques Nucleaires par decret de la Presidence du Conseil et de l'Education Nationale en date du 18.6.57. Cet Institut d'Enseignement Superieur (250 etudiants) donne des cours en: genie atomique, mecanique quantique, theorie et technique des Accelerateurs de particules, metallurgie speciale, radiobiologie

  7. The formation of scientists and technicians at the 'Centre d'Etudes Nucleaires' at Saclay

    International Nuclear Information System (INIS)

    Debiesse, J.

    1958-01-01

    The considerable needs in research workers and scientists which are asked by the nuclear energy obliged the Commissariat a l'Energie atomique to deal with a particular effort to increase the quantitative and qualitative formation of scientists. Most various ways have been used. 1- A National Institute of Nuclear Sciences and Nuclear Techniques was created, by a joint decree of the Prime Minister and the Minister for National Education (june 18, 1957). This Institute of Higher Teaching (250 students) indulges in the following matters: atomic engineering, quantum mechanics, theory and technic of particle accelerators, special metallurgy, radiobiology, thermic and mechanics of fluids. 2- An associated centre of the 'Conservatoire National des Arts et Metiers' was created (200 students) for technical assistants, drawers, etc. 3- In contribution with both electronic industry and Ministry of Work, the Centre d'Etudes Nucleaires contributes to an accelerated formation of technical assistants into Professional Centres. Conclusion: Training of scientists and research workers is one of the most important activities of the Centre d'Etudes Nucleaires de Saclay. Without losing its technical efficiency, it has supplied and varied means adapted to the various purposes that we shall reach. (author) [fr

  8. In situ gamma-ray spectrometric analysis of radionuclide distributions at a commercial shallow land burial site

    International Nuclear Information System (INIS)

    Kirby, L.J.; Campbell, R.M.

    1984-10-01

    Gamma-ray spectrometric analysis conducted at the Maxey Flats, Kentucky (USA) shallow land burial site confirmed that the waste radionuclides have been retained largely within the restricted area of the burial site. Concentrations of 137 Cs and 60 Co were comparable with those originating from global fallout and lower than concentrations measured in several other areas having similar rainfall. In-situ spectrometric analyses, corroborated by soil sample and vegetation analyses, indicate that the site has influenced 60 Co levels slightly in the west drainage channel, but 137 Cs did not originate from the site. Concentrations of 60 Co, 90 Sr and 137 Cs determined in subsurface soils by well logging techniques confirmed that subsurface migration of waste-derived radionuclides to points outside the restricted area has not been a significant source of contamination of the environs adjacent to the site. 8 references, 8 figures

  9. Mass spectrometric investigation of vinyl-substituted organic boron compounds

    International Nuclear Information System (INIS)

    Tarielashvili, V.O.; Ordzhonikidze, K.G.; Parulava, L.P.; Vakhaniya, G.V.

    1992-01-01

    Mass spectrometric investigation of vinyl-substituted organic compounds was conducted. Ionization was performed by electron shock. Possibility of determining boron isotope content is all analyzed organic boron vinyl-substituted compounds by direct method is shown. This simplifies sufficiently and lowers the price of analysis, improves its accuracy and rapidity

  10. Spectrometric determination of ammonium-nitrogen with quinol in ...

    African Journals Online (AJOL)

    Quinol is proposed as a reagent for the spectrometric determination of ammonium-nitrogen (NH4+-N) in aqueous medium. Quinol forms a pink complex with ammonium salt in aqueous medium. Hydrogen peroxide is needed for colour accentuation. The quinol/ammonium charge transfer complex has absorption maximum ...

  11. Preparation and spectrometric identification of amide derivatives with antimalaric

    International Nuclear Information System (INIS)

    Ferreira, E.J.

    1987-01-01

    The structures of polymeric compounds using spectrometric analysis of infrared, ultraviolet and protonic magnetic resonance and 13 C nuclear magnetic resonance are studied. Some structural models are used such as antimalaric-sulfones and pyrimidinic derivatives, and non-polymeric derivatives of active compounds. A comparative analysis on structures less complexes is shown. (M.J.C.). Spectrums 186 p [pt

  12. Determination of actinides by alpha spectrometric methods

    International Nuclear Information System (INIS)

    Galanda, D.

    2011-01-01

    defined attributes of mass activities of radionuclides in oyster mushroom's sporocarps compared to their sub-base. We used two methods to separate the monitored radionuclides in a radiochemical analyse. The first of them was an extraction fluid - fluid with Aliquat-336 to separate Pu and TOPO to separate Am. The second method was a proceeding modified by us and utilizing principles of an extraction chromatography with TRU Resin and DGA Resin sorbents made by Eichrom Company. An effectivity and a suitability of both applied methods were monitored following the attributes of radiochemical extractions used in tracer's radionuclides 242 Pu a 243 Am in this particular type of environmental samples. The reliability of the modified methodology, in accordance to selected criteria for validation of analytical method, was proved by comparison of both above mentioned methods. material delivered from IAEA, which presented a soil sample with code identification Soil IAEA-375. The obtained values of mass activities of 239 + 240 Pu, 239 Pu and 241 Am used in reference material, demonstrated a conformity with IAEA values, whereby we fulfilled one of the significant conditions of validate process. At the end of this thesis we applied the modified method of extraction chromatography with UTEVA Resin sorbent to define mass activities of uranium on soil and water samples where we monitored attributes of radiochemical extractions of 232 U tracer's radionuclide as the criteria of utilizability. The reliability of our modified method was verified by participation in international interlaboratory comparative proficiency tests and our results were in accordance with results of the reference laboratory. It means also a fulfilment of notable standard of the validate process. The results of all realized experimentations of radionuclides separation whether by extraction fluid - fluid or by extraction chromatography were determined by alpha-spectrometric measurements. (author)

  13. Analysis of solids by spark-source mass spectrometry; Analyse des solides au spectrometre de masse a etincelles

    Energy Technology Data Exchange (ETDEWEB)

    Stefani, R; Desjardins, M; Brun, J C; Cornu, A; Bourguillot, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-07-01

    Spark source mass spectrometer MS7 has been designed to determine traces of impurities in solids without standards. An atlas of 12 000 lines, assembled in the Grenoble laboratory, allows a quick investigation of mass spectra, notwithstanding their complexity due to multiply charged and polyatomic darkening. Photometric measurements increase accuracy calibration curve is known for each photo-plate. Further, reproducibility is better, if random fluctuations of matrix line darkening are corrected. So far, in a concentration range of 0,01 to 1 000 ppm (atomic), reproducibility is approximately 20 per cent, but absolute value of results depends on 'sensitivity coefficients'. (authors) [French] Le spectrometre de masse a etincelles, de type MS7, est destine a l'analyse chimique de traces dans les solides, sans echantillons etalons. L'emploi de catalogues de 12 000 raies, elabores au laboratoire, permet un depouillement rapide des spectres, malgre leur complexite due aux ionisations multiples et aux associations d'atomes. Le niveau d'apparition d'une impurete donne une estimation de sa teneur, mais la valeur du renseignement depend de la preparation des electrodes et de la connaissance plus ou moins approfondie des processus d'ionisation dans l'etincelle et de noircissement des emulsions photographiques. Les mesures photometriques augmentent la precision des resultats, si l'on determine systematiquement la courbe de noircissement de chaque plaque. De meme la reproductibilite est amelioree si l'on tient compte des fluctuations statistiques du noircissement de l'emulsion par les ions de la matrice. Actuellement, les concentrations mesurees dans le domaine de 0,01 a 1000 ppm atomiques sont reproductibles a 20 pour cent pres, mais leur valeur absolue n'est assuree qu'a un coefficient 3 pres. Des etudes sont en cours pour calibrer l'appareil en valeur absolue, par une determination des coefficients de sensibilite a partir d'echantillons etalons. (auteurs)

  14. A superheterodyne spectrometer for electronic paramagnetic. Resonance; Spectrometre superheterodyne de resonance paramagnetique electronique

    Energy Technology Data Exchange (ETDEWEB)

    Laffon, J L [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1963-12-15

    After a few generalities about electron paramagnetic resonance, a consideration of different experimental techniques authorises the choice of a particular type of apparatus. An EPR superheterodyne spectrometer built in the laboratory and having a novel circuit is described in detail. With this apparatus, many experimental results have been obtained and some of these are described as example. (author) [French] Apres quelques generalites sur le phenomene de resonance paramagnetique electronique, une synthese des differentes techniques experimentales, permet de fixer le choix d'un type d'appareillage. Un spectrometre de RPE superheterodyne realise en laboratoire et comportant un circuit original est expose dans le detail. Cet appareil a permis de nombreux resultats experimentaux dont quelques-uns sont decrits a titre d'exemple. (auteur)

  15. PENULISAN ETUDE-ETUDE MUSIK TALEMPONG UNGGAN (Sebuah Usaha Pembelajaran Musik Tradisi Berbasis Literatur

    Directory of Open Access Journals (Sweden)

    Asri MK

    2014-12-01

    Full Text Available “Talempong unggan”, a traditional music from Minangkabau community particularly in Unggan, Sumpur Kudus, Sijunjung Regency, West Sumatera Indonesia is classified into genre of “talempong duduak” (rea. Due to its special musical concept and the playing technics, this traditional music is selected as a practising course in the Karawitan Department of Indonesian Institute of Art (ISI Padang Panjang since 1993 till now. In a system of class learning with many students, Talempong Unggan definitely needs supporting methods and learning technics suitable for the course where the students can reach their maximum skills. All the melody of “talempong unggan” that has been made as a material of practice is transcribed to the system of numeric notation and rhythm motive of “gendang” and “aguang” which is written into signs and special notation. All of qualitative data is formulated into finding methods, technics and etude of learning ensamble of Talempong Unggan the traditional music that learned in Karawitan Department of ISI Padang Panjang. Key words: Talempong Unggan, Methods, Technics, Etude

  16. Stabilization of spectra provided by a gamma-ray spectrometer. Application to the construction of a stabilizer; Stabilisation des spectres fournis par un spectrometre a rayons gamma. Application a la realisation d'un stabilisateur

    Energy Technology Data Exchange (ETDEWEB)

    Detourne, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-06-15

    This research is concerned with the stabilization of spectra provided by a gamma-ray spectrometer. It is required to hold the calibration straight line of the spectrometer in a position which is fixed initially to better than 5x10{sup -5} channel. A prototype numerical stabilizer has been constructed : the SPECTROSTAB; it is made up of two independent control loops; one of these makes the spectrometer gain depend on the derivatives of a reference peak at high energies; the other makes the origin of the energy scale depend on the derivatives of a second reference peak at low energies A theoretical study of the behaviour of a control loop shows that a direct action stabilizer gives the most accurate stabilization; the loss in resolving power on the theoretical peaks of the spectra attains about 1 % with a scintillation detector, and 10 % with a semi-conductor detector. Various tests show that the expected results are obtained and that the displacement of the spectral peaks produced by the derivatives are hidden by errors in the calculation of the peak abscissae. (author) [French] Cette etude a pour objet la stabilisation des spectres fournis par un spectrometre a rayons gamma. On veut maintenir la droite d'etalonnage du spectrometre dans une position fixee initialement a mieux de 6.10{sup -5} canal pres. On realise un prototype de stabilisateur numerique, le SPECTROSTAB; il comprend deux boucles d'asservissement independantes; l'une d'elles asservit le gain du spectrometre aux derives d'un pic de reference aux hautes energies; l'autre asservit l'origine de l'echelle des energies aux derives d'un second pic de reference aux basses energies. Une etude theorique du comportement d'une boucle d'asservissement montre qu'un stabilisateur a action directe permet la stabilisation la plus precise; la perte en resolution sur les pics theoriques des spectres atteint environ 1 % avec un detecteur a scintillateur et 10 % avec un detecteur a semi-conducteur. Divers essais montrent

  17. Neutron spin echo spectroscopy. Its application to the study of the dynamics of polymers in solution; La spectrometrie par echos de spins de neutrons. Application a l'etude de la dynamique des polymeres en solution

    Energy Technology Data Exchange (ETDEWEB)

    Papoular, Robert

    1992-06-15

    This work focuses on Neutron Spin Echo (NSE) spectroscopy and on the NSE spectrometer MESS, which we have built at the L.L.B. (CE Saclay). After analyzing in detail the classical and quantum principles of this type of instrument, and illustrated them with optical analogies, we expound a simple formalism for the interpretation of polarized neutron experiments of the most general type. In a second part, we describe the MESS spectrometer extensively; its characteristics and performances as well as the first results obtained with this instrument. In particular, we include two papers showing how the neutron depolarization, spin rotation and echoes can be used to investigate high-Tc superconductors. The last part deals with the dynamics of Polymer-Polymer-Solvent ternary solutions and demonstrates how the Neutron Spin Echo technique becomes a privileged tool for such physico-chemical studies thanks to the joint use of NSE and contrast variation methods, coupled with the adequate ranges of time and scattering vectors accessible. Finally, we describe the specific case of partially deuterated polydimethyl-siloxane (PDMS) in semi-dilute solution in Toluene. We have experimentally and separately evidenced the cooperative and inter-diffusive diffusion modes predicted by the theory of Akcasu, Benoit, Benmouna et al. These results, obtained at the L.L.B. (CE Saclay) are the subject matter of the last paper included in this work. (author) [French] Ce memoire est centre sur la spectroscopie par echos de spins de neutrons, et plus particulierement, sur le spectrometre a echos de spins MESS que nous avons construit au L.L.B (CE/Saclay). Apres avoir detaille les principes classique et quantique de ce type d'instrument et les avoir illustres par des analogies optiques, nous detaillons un formalisme simple permettant d'interpreter les experiences utilisant les neutrons polarises dans le cas le plus general. Une seconde partie decrit de maniere approfondie le spectrometre MESS de Saclay

  18. The use of radiotracer techniques to study lubrication and wear in large diesel engines; Emploi des indicateurs radioactifs pour l'etude de la lubrification et de l'usure dans les moteurs diesel de grande puissance; Ispol'zovanie metodov radioaktivnykh indikatorov dlya izucheniya smazki i iznosa bol'shikh dizel'nykh motorov; Aplicacion de los indicadores radiactivos al estudio de la lubricacion y desgaste de los motores diesel de gran potencia

    Energy Technology Data Exchange (ETDEWEB)

    Howes, Jr, J E; Braun, W J; Sunderman, D N [Battelle Memorial Institute, Columbus, OH (United States)

    1962-01-15

    Radiotracer techniques have been applied to the study of lubrication and wear in large diesel engines on a scale not before considered practical, with perfect safety and with unique technological results. Both lubricating-oil consumption and cylinderliner wear have been evaluated as a function of operating conditions on diesel engines in the 1000 HP range. Techniques were developed for tapping 200 gal (US) of lubricating oil with 60 mc of zinc-65 and determining oil consumption by sampling exhaust gas during operation under a variety of conditions. Measurement of the rate of lubeoil consumption could be made in 10 min rather than the 24 to 48 h previously required. Irradiation techniques were developed for neutron activation of the lower cylinder portion of a 48-in long, 8-in diam. cylinder liner. Suitable thermal-neutron shielding allowed production of 300-d manganese-54 which resulted in extending the useful life of the liner for wear studies by a factor of six to eight over that of a comparable liner thermally activated to produce iron-59. The fact that studies with such large quantities of radioactive material can be carried out in standard research facilities in the diesel engine field opens an entirely new area to tracer applications. Selective activation and judicious use of thermalneutron shielding increases the versatility of the tracer technique in localizing measurement to areas of interest, reducing the total quantity of radioactive material required in wear studies of large parts, and facilitating simultaneous wear-measurement on engine parts of identical chemical composition. (author) [French] On s'est servi d'indicateurs radioactifs pour l'etude de la lubrification et de l'usure des moteurs diesel de grande puissance, et cela a une echelle qui jusqu'a present n'etait pas consideree comme pratiquement realisable, avec m e securite parfaite et des resultats technologiques sans precedent. La consommation de l'huile de graissage et l'usure des chemises

  19. Mass-spectrometric measurements for nuclear safeguards

    International Nuclear Information System (INIS)

    Carter, J.A.; Smith, D.H.; Walker, R.L.

    1982-01-01

    The need of an on-site inspection device to provide isotopic ratio measurements led to the development of a quadrupole mass spectrometer mounted in a van. This mobile laboratory has the ability, through the use of the resin bead technique, to acquire, prepare, and analyze samples of interest to nuclear safeguards. Precision of the measurements is about 1 to 2%

  20. System for Gamma an X rays fluorescence spectrometric

    International Nuclear Information System (INIS)

    Alonso Abad, D.; Arista Romeu, E.; Bolanos Perez, L. and others

    1997-01-01

    A system for spectrometry of gamma or fluorescence X rays is presented. It sis composed by a Si(Li) semiconductors detector, a charge sensitive preamplifier, a high voltage power supply, a spectrometric amplifier and a monolithic 1024 channels multichannel analyzers or an IBM compatible 4096 channels add - on- card multichannel analyzer. The system can be configured as a 1024 or 4096 channels gamma or fluorescent X rays spectrometer

  1. Electrospray Ionization Mass Spectrometric Analysis of Highly Reactive Glycosyl Halides

    Directory of Open Access Journals (Sweden)

    Lajos Kovács

    2012-07-01

    Full Text Available Highly reactive glycosyl chlorides and bromides have been analysed by a routine mass spectrometric method using electrospray ionization and lithium salt adduct-forming agents in anhydrous acetonitrile solution, providing salient lithiated molecular ions [M+Li]+, [2M+Li]+ etc. The role of other adduct-forming salts has also been evaluated. The lithium salt method is useful for accurate mass determination of these highly sensitive compounds.

  2. Mass spectrometric detection of radiocarbon for dating applications

    OpenAIRE

    Synal Hans-Arno

    2013-01-01

    Radiocarbon is still the most important nuclide measured by accelerator mass spectrometry (AMS). The related capabilities for dating and tracer studies are eminent not only in archaeology but also drive important applications in the earth and environmental sciences as well as in biomedical research. So far standard mass spectrometric systems have not been capable of radiocarbon dating because of interfering molecular isobars which however can be completely eliminated in charge changing proces...

  3. Gamma spectrometric system based on the personal computer Pravetz-83

    International Nuclear Information System (INIS)

    Yanakiev, K; Grigorov, T.; Vuchkov, M.

    1985-01-01

    A gamma spectrometric system based on a personal microcomputer Pravets-85 is described. The analog modules are NIM standard. ADC data are stored in the memory of the computer via a DMA channel and a real-time data processing is possible. The results from a series of tests indicate that the performance of the system is comparable with that of comercially avalable computerized spectrometers Ortec and Canberra

  4. Neutron activation and mass spectrometric measurement of /sup 129/I

    International Nuclear Information System (INIS)

    Strebin, R.S. Jr.; Brauer, F.P.; Kaye, J.H.; Rapids, M.S.; Stoffels, J.J.

    1987-11-01

    An integrated procedure has been developed for measurement of /sup 129/I by neutron activation analysis and mass spectrometry. An iodine isolation procedure previously used for neutron activation has been modified to provide separated iodine suitable for mass spectrometric measurement as well. Agreement between both methods has been achieved within error limits. The measurement limit by each method is about 10/sup 7/ atoms (2 fg) of /sup 129/I. 13 refs,. 4 figs., 1 tab

  5. Gamma spectrometrical examination of irradiated fuel

    International Nuclear Information System (INIS)

    Kristof, Edvard; Pregl, Gvido

    1988-01-01

    Gamma scanning is the only non-destructive technique for quantitative measuring of fission or activation products in spent fuel. The negligence of local variation of the linear attenuation coefficient of gamma rays in the irradiated fuel remains the main source of systematic error. To eliminate it we combine the (single) emission gamma ray scanning technique with a transmission measurement. Mathematical procedure joined with the experiment is particularly convenient for fuel elements of circular cross-section. In such a manner good results are obtainable even for relatively small number of measuring data. Accomplished routines enable to esteem the finite width of the collimation slit. The experiment has been partially automated. Trial measurements were carried out, and the measured data were successfully processed

  6. Gamma spectrometric methods for measuring plutonium

    International Nuclear Information System (INIS)

    Gunnink, R.

    1978-01-01

    Nondestructive analyses of plutonium can be made by detecting and measuring the gamma rays emitted by a sample. Although qualitative and semiquantitative assays can be performed with relative ease, only recently have methods been developed, using computer analysis techniques, that provide quantitative results. This paper reviews some new techniques developed for measuring plutonium. The features of plutonium gamma-ray spectra are reviewed and some of the computer methods used for spectrum analysis are discussed. The discussion includes a description of a powerful computer method of unfolding complex peak multiplets that uses the standard linear least-squares techniques of data analysis. This computer method is based on the generation of response profiles for the isotopes composing a plutonium sample and requires a description of the peak positions, relative intensities, and line shapes. The principles that plutonium isotopic measurements are based on are also developed, followed by illustrations of the measurement procedures as applied to the quantitative analysis of plutonium liquid and solid samples

  7. Development of analytical techniques for determining rare earth elements in geological materials

    International Nuclear Information System (INIS)

    Moraes, Noemia M.P. de; Kakazu, M.H.; Iyer, S.S.

    1987-01-01

    This work presents a comparative study between instrumental neutron activation analysis, inductively coupled plasma emission spectrometry and mass spectrometric isotope dilution techniques. Some advantages and disadvantages of the techniques are presented, depending on the type of the analysis required. Emphasis in give upon mass spectrometric isotope dilution, and some procedures for the development of this technique are presented. This methodology is being established by the nuclear and isotopic geology group of the IPEN. (author) [pt

  8. Gas Chromatographic Mass Spectrometric Determination of Myo-inositol in Humans Utilizing a Deuterated Internal Standard

    DEFF Research Database (Denmark)

    Andersen, Jan Rud; Larsen, Elfinn; Harbo, Helge

    1982-01-01

    The isotopic dilution technique was used for determining the content of myo-inositol in human urine, plasma and haemolysed erythrocyte samples. A deuterated myo-inositol, synthesized from inosose-2 by base-catalysed exchange of hydrogens by deuterium, followed by reduction of the inosose with 2H2......, was added as internal standard to the samples at an early stage in the analytical procedure. After separation and derivatization to the hexa-acetate, the gas chromatographic mass spectrometric analysis was carried out. A 25 m fused silica capillary column coated with methyl silicone was used, and the ions...... selected for monitoring were m/z 210 and m/z 214, which are characteristic and abundant fragment ions from unlabelled and hexadeuterated myo-inositolhexa-acetate, respectively. Calibration curves from water, urine, plasma and haemolysed erythrocytes show parallel, linear responses in the ratio between...

  9. Identification of volatiles by headspace gas chromatography with simultaneous flame ionization and mass spectrometric detection.

    Science.gov (United States)

    Tiscione, Nicholas B; Yeatman, Dustin Tate; Shan, Xiaoqin; Kahl, Joseph H

    2013-10-01

    Volatiles are frequently abused as inhalants. The methods used for identification are generally nonspecific if analyzed concurrently with ethanol or require an additional analytical procedure that employs mass spectrometry. A previously published technique utilizing a capillary flow technology splitter to simultaneously quantitate and confirm ethyl alcohol by flame ionization and mass spectrometric detection after headspace sampling and gas chromatographic separation was evaluated for the detection of inhalants. Methanol, isopropanol, acetone, acetaldehyde, toluene, methyl ethyl ketone, isoamyl alcohol, isobutyl alcohol, n-butyl alcohol, 1,1-difluoroethane, 1,1,1-trifluoroethane, 1,1,1,2-tetrafluoroethane (Norflurane, HFC-134a), chloroethane, trichlorofluoromethane (Freon®-11), dichlorodifluoromethane (Freon®-12), dichlorofluoromethane (Freon®-21), chlorodifluoromethane (Freon®-22) and 1,2-dichlorotetrafluoroethane (Freon®-114) were validated for qualitative identification by this method. The validation for qualitative identification included evaluation of matrix effects, sensitivity, carryover, specificity, repeatability and ruggedness/robustness.

  10. Mass spectrometric isotope dilution analyses of palladium, silver, cadmium and tellurium in carbonaceous chondrites

    International Nuclear Information System (INIS)

    Loss, R.D.; Rosman, K.J.R.; De Laeter, J.

    1984-01-01

    The mass spectrometric isotope dilution technique was used to measure the elemental abundances of Pd, Ag, Cd and Te in Orgueil (C1), Ivuna (C1), Murray (C2) and Allende (C3) chondrites. The Pd abundance of 554 ppb for the Cl chondrites is almost identical to the recommended value of Anders and Ebihara (1982); that for Cd (712 ppb) is approximately 5% higher, whereas that for Ag (198 ppb) is approximately 10% lower than the recommended values. A smooth distribution for the abundances of the odd-A nuclides between 65 128 Te and 130 Te to lie approximately 30% above the r-process peak at A = 130, whereas the new value fits smoothly into the general trend. (author)

  11. MASS SPECTROMETRIC ANALYSIS FOR THE IDENTIFICATION OF THUNNUS GENUS FOUR SPECIES

    Directory of Open Access Journals (Sweden)

    T. Pepe

    2011-01-01

    Full Text Available An accurate identification of similar fish species is necessary to prevent illegal substitution and is imposed by labeling regulations in UE countries (1. The genus Thunnus comprises many species of different quality and commercial value. The increasing trade of fish preparations of the species included in this genus and the consequent loss of the external anatomical and morphological features enables fraudulent substitutions. This study reports data relating to the proteomic analysis of four tuna species (T. thynnus, T. alalunga, T. albacares, T. obesus. Sarcoplasmic proteins were studied by mono and two dimensional electrophoresis. The most significant proteins for the characterization of the species were analyzed by mass spectrometric techniques. As reported in a previous study (2, an accurate identification of the species seems possible, owing to the polymorphism displayed by the species of the Thunnus genus.

  12. Mass-Spectrometric Studies of Catalytic Chemical Vapor Deposition Processes of Organic Silicon Compounds Containing Nitrogen

    Science.gov (United States)

    Morimoto, Takashi; Ansari, S. G.; Yoneyama, Koji; Nakajima, Teppei; Masuda, Atsushi; Matsumura, Hideki; Nakamura, Megumi; Umemoto, Hironobu

    2006-02-01

    The mechanism of catalytic chemical vapor deposition (Cat-CVD) processes for hexamethyldisilazane (HMDS) and trisdimethylaminosilane (TDMAS), which are used as source gases to prepare SiNx or SiCxNy films, was studied using three different mass spectrometric techniques: ionization by Li+ ion attachment, vacuum-ultraviolet radiation and electron impact. The results for HMDS show that Si-N bonds dissociate selectively, although Si-C bonds are weaker, and (CH3)3SiNH should be one of the main precursors of deposited films. This decomposition mechanism did not change when NH3 was introduced, but the decomposition efficiency was slightly increased. Similar results were obtained for TDMAS.

  13. Mass spectrometric 230Th-234U-238U dating of the Devils Hole calcite vein

    International Nuclear Information System (INIS)

    Ludwig, K.R.; Simmons, K.R.; Szabo, B.J.; Riggs, A.C.; Winograd, I.J.; Landwehr, J.M.; Hoffman, R.J.

    1992-01-01

    The Devils Hole calcite vein contains a long-term climatic record, but requires accurate chronologic control for its interpretation. Mass-spectrometric U-series ages for samples from core DH-11 yielding 230 Th ages with precisions ranging from less than 1,000 years (2σ) for samples younger than ∼140 ka (thousands of years ago) to less than 50,000 years for the oldest samples (∼566 ka). The 234 U/ 238 U ages could be determined to a precision of ∼20,000 years for all ages. Calcite accumulated continuously from 566 ka until ∼60 ka at an average rate of 0.7 millimeter per 10 3 years. The precise agreement between replicate analyses and the concordance of the 230 Th/ 238 U and 234 U/ 238 U ages for the oldest samples indicate that the DH-11 samples were closed systems and validate the dating technique in general

  14. Implementing Formative Assessment in Engineering Education: The Use of the Online Assessment System Etude

    Science.gov (United States)

    Dopper, Sofia M.; Sjoer, Ellen

    2004-01-01

    This article describes the possibilities offered by the online assessment system Etude to achieve the benefits of formative assessment. In order to find out the way this works in practice, we carried out an experiment with the use of Etude for formative assessment in the course on collaborative report writing. Results show that online formative…

  15. A review on the mass spectrometric studies of americium: Present status and future perspective.

    Science.gov (United States)

    Aggarwal, Suresh Kumar

    2018-01-01

    The manuscript reviews the various mass spectrometric techniques for analysis and chemical studies of Americium. These methods include thermal ionization mass spectrometry (TIMS), and inductively coupled plasma source mass spectrometry (ICPMS) for the determination of Am isotope ratios and concentration in nuclear fuel samples of interest in nuclear technology, and in complex biological and environmental samples. Ultra-sensitive mass spectrometric techniques of resonance-ionization mass spectrometry (RIMS), and accelerator-based mass spectrometry (AMS) are also discussed. The novel applications of electrospray ionization mass spectrometry (ESIMS) to understand the solution chemistry of Am and other actinides are presented. These studies are important in view of the world-wide efforts to develop novel complexing agents to separate lanthanides and minor actinides (Am, Np, and Cm) for partitioning and transmutation of minor actinides from the point of view of nuclear waste management. These mass spectrometry experiments are also of great interest to examine the covalent character of actinides with increasing atomic number. Studies on gas-phase chemistry of Am and its oxides with Knudsen effusion mass spectrometry (KEMS), Fourier-transform ion cyclotron resonance mass spectrometry (FTICR-MS), and laser-based experiments with reflectron time-of-flight mass spectrometer (R-ToF) are highlighted. These studies are important to understand the fundamental chemistry of 5f electrons in actinides. Requirement of certified isotopic reference materials of Am to improve the accuracy of experimental nuclear data (e.g., the half-life of 243 Am) is emphasized. © 2016 Wiley Periodicals, Inc. Mass Spec Rev. © 2016 Wiley Periodicals, Inc.

  16. Point-of-care ultrasonography adoption in Canada: using diffusion theory and the Evaluation Tool for Ultrasound skills Development and Education (ETUDE).

    Science.gov (United States)

    Woo, Michael Y; Frank, Jason R; Lee, A Curtis

    2014-09-01

    Point-of-care ultrasonography (PoCUS) first appeared in the 1980s in North America, but the extent of the diffusion of its adoption is unknown. We characterized early PoCUS adoption by emergency physicians in Canada and its barriers to use using Rogers' diffusion of innovations theory. We developed a questionnaire based on a pilot study and literature review to assess past, current, and potential use of PoCUS and potential barriers to adoption. A Dillman technique for electronic surveys was used for dissemination. Using Rogers' diffusion of innovations theory, we developed and validated the Evaluation Tool for Ultrasound skills Development and Education (ETUDE). ETUDE scores allowed categorization of respondents into innovators, early adopters, majority, and nonadopters. Descriptive statistics, correlations, and χ² statistics were used to analyze the data. The 296 respondents (36.4% of 814 surveyed) had a median age of 40 and were 72.5% male. Adoption scores using ETUDE revealed nonadopters (18.8%), majority (28.7%), early adopters (34.5%), and innovators (18.0%). Respondents endorsed "always" using PoCUS currently and in the future for focused assessment with sonography in trauma (FAST) (current 41.8%/future 88.4%), first trimester pregnancy (current 23.3%/future 73.7%), suspected abdominal aortic aneurysm (current 32.7%/future 92.6%), basic cardiac indications (current 30.7%/future 87.5%), and central venous catheterization (current 17.0%/future 80.3%). Several barriers to PoCUS were identified for part-time emergency physicians and those working in inner-city/urban/suburban settings. This is the first study to determine the state of adoption and barriers to the introduction of PoCUS in Canadian emergency medicine practice. The novel validated ETUDE instrument should be used to evaluate the uptake of PoCUS over time.

  17. Particle desorption mass spectrometric surface characterization

    International Nuclear Information System (INIS)

    Summers, W.R.

    1986-01-01

    The feasibility of utilizing 252 Cf-Particle Desorption Mass Spectrometry (PDMS) to characterize the surface region of solid samples has been evaluated. The PDMS experiment was adapted to an ultrahigh vacuum (UHV) environment and was configured so as to allow the analysis of thick as well as thin samples. This apparatus included an in situ sputter cleaning/depth profiling facility. The mass resolution was variable from 300 to 200 at 133 daltons by changing the drift length from 27 cm to 20 cm. Desorbed ions were focused by using either a dual grid assembly or an einzel lens. The overall instrumental transmission efficiency with the einzel lens operative was approximately 50%. The applicability of 252 Cf-PDMS to samples that were thick and insulating was demonstrated in the analysis of geological specimens. Pollucite, Microcline, Amblygonite, and Lepidolite were analyzed without complications associated with sample thickness or charge accumulation. Substitution occurring between the alkali metals in the environment was observed by PDMS and was corroborated by SIMS, XPS, and EMP analyses. The analysis of NBM SRM glasses addressed the suitability of combining the PDMS technique was sputter etching. This application demonstrated the ability of this technique to sense changes in the chemical environment brought about by sputter cleaning. The analysis of these samples also allowed the estimation of detection limits for lithium, rubidium, and cesium in a glass matrix as 300 ppm, 400 ppm, and 400 ppm, respectively. Sputter depth profiling combined with 252 Cf-PDMS analysis of an aluminum layer on a silicon substrate established the utility of the PDMS technique in surface characterization

  18. Mass spectrometric methods for studying nutrient mineral and trace element absorption and metabolism in humans using stable isotopes: a review

    International Nuclear Information System (INIS)

    Crews, H.M.; Eagles, J.; Mellon, F.A.; Luten, J.B.; McGaw, B.A.

    1994-01-01

    Mass spectrometric methods for determining stable isotopes of nutrient minerals and trace elements in human metabolic studies are described and discussed. The advantages and disadvantages of the techniques of electron ionization, fast atom bombardment, thermal ionization, and inductively coupled plasma and gas chromatography mass spectrometry are evaluated with reference to their accuracy, precision, sensitivity, and convenience, and the demands of human nutrition research. Examples of specific applications are described and the significance of current developments in mass spectrometry are discussed with reference to present and probable future research needs. (Author)

  19. Speciation and detection of arsenic in aqueous samples: A review of recent progress in non-atomic spectrometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Jian [State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen 361102 (China); Department of Chemistry and Biochemistry, University of Texas, 700 Planetarium Place, Arlington, TX 76019 (United States); Sengupta, Mrinal K. [Department of Chemistry and Biochemistry, University of Texas, 700 Planetarium Place, Arlington, TX 76019 (United States); Thermo Fisher Scientific, Dionex Products, 445 Lakeside Drive, Sunnyvale, CA, 94085 (United States); Yuan, Dongxing [State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen 361102 (China); Dasgupta, Purnendu K., E-mail: Dasgupta@uta.edu [Department of Chemistry and Biochemistry, University of Texas, 700 Planetarium Place, Arlington, TX 76019 (United States)

    2014-06-01

    Highlights: • Compilation of principal official documents and major review articles, including the toxicology and chemistry of As. • Review of non-atomic spectrometric methods for speciation and detection of arsenic in aqueous samples (2005–2013) of the performance of field-usable methods. - Abstract: Inorganic arsenic (As) displays extreme toxicity and is a class A human carcinogen. It is of interest to both analytical chemists and environmental scientists. Facile and sensitive determination of As and knowledge of the speciation of forms of As in aqueous samples are vitally important. Nearly every nation has relevant official regulations on permissible limits of drinking water As content. The size of the literature on As is therefore formidable. The heart of this review consists of two tables: one is a compilation of principal official documents and major review articles, including the toxicology and chemistry of As. This includes comprehensive official compendia on As speciation, sample treatment, recommended procedures for the determination of As in specific sample matrices with specific analytical instrument(s), procedures for multi-element (including As) speciation and analysis, and prior comprehensive reviews on arsenic analysis. The second table focuses on the recent literature (2005–2013, the coverage for 2013 is incomplete) on As measurement in aqueous matrices. Recent As speciation and analysis methods based on spectrometric and electrochemical methods, inductively coupled plasma-mass spectrometry, neutron activation analysis and biosensors are summarized. We have deliberately excluded atomic optical spectrometric techniques (atomic absorption, atomic fluorescence, inductively coupled plasma-optical emission spectrometry) not because they are not important (in fact the majority of arsenic determinations are possibly carried out by one of these techniques) but because these methods are sufficiently mature and little meaningful innovation has been

  20. Speciation and detection of arsenic in aqueous samples: A review of recent progress in non-atomic spectrometric methods

    International Nuclear Information System (INIS)

    Ma, Jian; Sengupta, Mrinal K.; Yuan, Dongxing; Dasgupta, Purnendu K.

    2014-01-01

    Highlights: • Compilation of principal official documents and major review articles, including the toxicology and chemistry of As. • Review of non-atomic spectrometric methods for speciation and detection of arsenic in aqueous samples (2005–2013) of the performance of field-usable methods. - Abstract: Inorganic arsenic (As) displays extreme toxicity and is a class A human carcinogen. It is of interest to both analytical chemists and environmental scientists. Facile and sensitive determination of As and knowledge of the speciation of forms of As in aqueous samples are vitally important. Nearly every nation has relevant official regulations on permissible limits of drinking water As content. The size of the literature on As is therefore formidable. The heart of this review consists of two tables: one is a compilation of principal official documents and major review articles, including the toxicology and chemistry of As. This includes comprehensive official compendia on As speciation, sample treatment, recommended procedures for the determination of As in specific sample matrices with specific analytical instrument(s), procedures for multi-element (including As) speciation and analysis, and prior comprehensive reviews on arsenic analysis. The second table focuses on the recent literature (2005–2013, the coverage for 2013 is incomplete) on As measurement in aqueous matrices. Recent As speciation and analysis methods based on spectrometric and electrochemical methods, inductively coupled plasma-mass spectrometry, neutron activation analysis and biosensors are summarized. We have deliberately excluded atomic optical spectrometric techniques (atomic absorption, atomic fluorescence, inductively coupled plasma-optical emission spectrometry) not because they are not important (in fact the majority of arsenic determinations are possibly carried out by one of these techniques) but because these methods are sufficiently mature and little meaningful innovation has been

  1. 98 Etude Comparative du Systeme Phonematique et Tonal des ...

    African Journals Online (AJOL)

    98. Etude Comparative du Systeme Phonematique et Tonal des. Deux Parlers: Le Yoruba du Nigeria et L'itsa Parle en. Republique du Benin. Ajani Akinwumi Lateef et Ayuba G. Ajibabi http://dx.doi./org/10.4314/ujah.v18i3.5. Résume. En ce début de l'époque ou la mondialisation et la coexistence des peuples dans le ...

  2. Nuclear study of Melusine; Etude nucleaire de Melusine

    Energy Technology Data Exchange (ETDEWEB)

    Cherot, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    In this report are reviewed - with respect to starting of experiments - the main nuclear characteristics of a 20 per cent enriched uranium lattice, with light water as moderator and reflector. The reactor is to operate at 1 MW. 1) Study of various critical masses. 2) Control. Effectiveness of cadmium. Control rods and of a stainless steel regulating rod. 3) Study of the effect on reactivity of disturbances in the core center. 4) Study of xenon and samarium poisoning. 5) Temperature factor. 6) Heat exchanges in a fuel element. (author) [French] On etudie, dans ce rapport, les principales proprietes nucleaires d'un reseau a uranium enrichi (20 pour cent), dont le moderateur et le reflecteur sont l'eau legere en vue des experiences de demarrage. Ce reacteur devra fonctionner a 1 MW. 1) Etude de diverses masses critiques. 2) Controle. Efficacite des barres de controle en cadmium et d'une barre de reglage en acier inoxydable. 3) Etude de l'effet sur la reactivite de perturbation au centre du coeur. 4) Etude de l'empoisonnement xenon et samarium. 5) Coefficient de temperature. 6) Echanges thermiques dans un element. (auteur)

  3. Mass spectrometric analysis of simple hydrogen compounds; Analyse de composes hydrogenes simples au spectrometre de masse

    Energy Technology Data Exchange (ETDEWEB)

    Nief, C; Botter, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    A uranium furnace is inserted in the gas inlet line of a mass spectrometer between the leak and the source. The line is fed with simple hydrogen compounds (H{sub 2}O, NH{sub 3}, H{sub 2}S) which are in this way reduced to hydrogen gas. Memory effects are largely avoided by heating the sample line to 90 deg. C. The speed of the isotopic analysis is only slightly less than that of hydrogen gas itself; the accuracy is better due to the reduction of fractionating effects in the leak. For the absolute measurements of deuterium in water, the presence of H{sub 3}{sup +} is a problem. Water samples, prepared by mixing an unknown light water sample with different amounts of heavy water, are equilibrated with hydrogen sulphide and analysis of the two phases of each sample enables the zero of the concentration scale to be determined from the point of intersection of the two curves obtained by plotting mixture composition against the observed isotope ratio in the two phases. The whole experiment can be carried out in the apparatus described which analyses hydrogen in H{sub 2}S and H{sub 2}O in the same way. (author) [French] Un four a uranium est insere dans la ligne d'introduction de gaz d'un spectrometre de masse entre la fuite et la source. La ligne est alimentee par des composes hydrogenes simples (H{sub 2}O, NH{sub 3}, H{sub 2}S) qui sont de cette facon transformes en hydrogene gazeux. On evite dans une large mesure les effets de memoire en chauffant la ligne de l'echantillon jusqu'a 90 deg. C. La vitesse de l'analyse isotopique est seulement legerement inferieure a celle de l'hydrogene gazeux lui-meme; la precision est meilleure du fait de la reduction des effets de fractionnement dans la fuite. Pour les mesures absolues du deuterium dans l'eau, la presence de H{sub 3}{sup +} pose un probleme. Les echantillons d'eau, prepares en melangeant un echantillon inconnu d'eau legere a differentes quantites d'eau lourde, sont equilibres par de l'hydrogene sulfure et l'analyse de

  4. Challenges and recent advances in mass spectrometric imaging of neurotransmitters

    Science.gov (United States)

    Gemperline, Erin; Chen, Bingming; Li, Lingjun

    2014-01-01

    Mass spectrometric imaging (MSI) is a powerful tool that grants the ability to investigate a broad mass range of molecules, from small molecules to large proteins, by creating detailed distribution maps of selected compounds. To date, MSI has demonstrated its versatility in the study of neurotransmitters and neuropeptides of different classes toward investigation of neurobiological functions and diseases. These studies have provided significant insight in neurobiology over the years and current technical advances are facilitating further improvements in this field. neurotransmitters, focusing specifically on the challenges and recent Herein, we advances of MSI of neurotransmitters. PMID:24568355

  5. Photometric and emission-spectrometric determination of boron in steels

    International Nuclear Information System (INIS)

    Thierig, D.

    1982-01-01

    A method for the photometric determination of boron in unalloyed and alloyed steels is described, in which Curcumine is used as reagent. A separation of boron is not necessary. Limit of detection: 0.0003% B. The decomposition of boron nitride in the steel is achieved by heating the whole sample in fuming sulphuric acid/phosphoric acid. For the emission spectrometric investigation of solid steel samples and for the spectrochemical analysis of solutions with plasma excitation working parameters are given and possibilities of interferences are demonstrated. (orig.) [de

  6. Mass spectrometric study of Nd2S3 vaporization

    International Nuclear Information System (INIS)

    Fenochka, B.V.

    1987-01-01

    The authors conduct a mass-spectrometric study of neodymium(III) sulfide vaporization. The chemical composition of the samples was stoichiometric and the samples were vaporized from tantalum effusion cells. When the vapor over Nd 2 S 3 is ionized by electrons the mass spectra shows monovalent cations of Nd, S, NdS, and NdO. The enthalpy of vaporization if Nd atoms from Nd 2 S 3 at average experimental temperatures and the standard enthalpy of reaction is shown. Also presented is the enthalpy of vaporization of NdS molecules from Nd 2 S 3 at average experimental temperatures and the standard enthalpy of reaction

  7. Gamma spectrometric analyses of environmental samples at PINSTECH

    International Nuclear Information System (INIS)

    Faruq, M.U.; Parveen, N.; Ahmed, B.; Aziz, A.

    1979-01-01

    Gamma spectrometric analyses of air and other environmental samples from PINSTECH were carried out. Air particulate samples were analyzed by a Ge(Li) detector on a computer-based multichannel analyzer. Other environmental samples were analyzed by a Na(T1) scintillation detector spectrometer and a multichannel analyzer with manual analysis. Concentration of radionuclides in the media was determined and the sources of their production were identified. Age of the fall out was estimated from the ratios of the fission products. (authors)

  8. Mass spectrometric investigation of fluorated europium. beta. -diketonates. [Electrons

    Energy Technology Data Exchange (ETDEWEB)

    Khomenko, V.S.; Lozinskij, M.O.; Fialkov, Yu.A.; Rasshinina, T.A.; Suboch, V.P. (AN Belorusskoj SSR, Minsk. Inst. Fiziki; AN Ukrainskoj SSR, Kiev. Inst. Organicheskoj Khimii)

    Ternary complexes of europium with two organic ligands - fluorated ..beta..-diketone and organic base - in the aqueous phase at electron shock are investigated; regroupings that take place in them are established. Mass-spectrometric investigation has shown that complexes with ..beta..-diketones, containing in oxygen atom in a fluorated radical, eliminate stable molecules of difluorophosgen, CoF/sub 2/. For the complexes studied under the above conditions the Co molecule elimination is also typical which is accompanied by the formation of ions with a metal-carbon bond.

  9. Mass spectrometric investigation of fluorated europium β-diketonates

    International Nuclear Information System (INIS)

    Khomenko, V.S.; Lozinskij, M.O.; Fialkov, Yu.A.; Rasshinina, T.A.; Suboch, V.P.; AN Ukrainskoj SSR, Kiev. Inst. Organicheskoj Khimii)

    1983-01-01

    Ternary complexes of europium with two organic lidands - fluorated β-diketone and organic base - in the aqueous phase at electron shock are investigated; regroupings that take place in them are established. Mass-spectrometric investigation has shown that complexes with β-diketones, containing in oxygen atom in a fluorated radical, eliminate stable molecules of difluorophosgen, CoF 2 . For the complexes studied under the above conditions the Co molecule elimination is also typical which is accompanied by the formation of ions with a metal-carbon bond

  10. Determination of uranium enrichment by using gamma-spectrometric methods

    International Nuclear Information System (INIS)

    Kutnyj, D.V.; Telegin, Yu.N.; Odejchuk, N.P.; Mikhailov, V.A.; Tovkanets, V.E.

    2009-01-01

    By using commercial analysis programs MGAU (LLNL, USA) and FRAM (LANL, USA) the summary error of gamma-spectrometric uranium enrichment measurements was investigated. Uranium samples with enrichments of 0,71; 4,46 and 20,1 % were measured. The coaxial high purity germanium detector (type GC) and the planar germanium detector (type LEGe) were used as gamma-radiation detectors. It was shown that experimental equipment and mathematical software available in NSC KIPT allow us to measure uranium enrichment by nondestructive method with accuracy of not worse than 2%.

  11. A gas/liquid chromatographic-mass spectrometric method for the rapid screening of 250 pesticides in aqueous matrices

    Energy Technology Data Exchange (ETDEWEB)

    Chandramouli, B.; Harvan, D.; Brittain, S.; Hass, R. [Eno River Labs, LLC. Durham, NC (United States)

    2004-09-15

    Pesticide residues in food present a potentially serious and significant cause for concern. Many pesticides have been associated with significant health effects to the nervous and endocrine systems and some have been deemed carcinogenic. There are many well-established techniques for pesticide analysis. However, commercial pesticide methods have traditionally only been available for specific pesticide families, such as chlorinated pesticides or herbicides, and at detection limits ranging from 0.05 ppb to 1 ppm in aqueous matrices. Techniques that can quickly screen for the presence/absence of pesticide residues in food matrices are critical in ensuring the safety of food and water. This paper outlines a combined Gas Chromatographic-High Resolution Mass Spectrometric (GC-HRMS) and Liquid Chromatographic Tandem Mass Spectrometric (LC-MS/MS) screening assay for 250 pesticides that was developed for use in water, and soda samples at screening levels ranging from 0.1-5 ppb. The pesticides selected have been identified by the European Union as being of concern and the target of possible legislation. The list encompasses a variety of pesticide classes and compound groupings.

  12. Quantitative mass-spectrometric analysis of hydrogen helium isotope mixtures

    International Nuclear Information System (INIS)

    Langer, U.

    1998-12-01

    This work deals with the mass-spectrometric method for the quantitative analysis of hydrogen-helium-isotope mixtures, with special attention to fusion plasma diagnostics. The aim was to use the low-resolution mass spectrometry, a standard measuring method which is well established in science and industry. This task is solved by means of the vector mass spectrometry, where a mass spectrum is repeatedly measured, but with stepwise variation of the parameter settings of a quadruple mass spectrometer. In this way, interfering mass spectra can be decomposed and, moreover, it is possible to analyze underestimated mass spectra of complex hydrogen-helium-isotope mixtures. In this work experimental investigations are presented which show that there are different parameters which are suitable for the UMS-method. With an optimal choice of the parameter settings hydrogen-helium-isotope mixtures can be analyzed with an accuracy of 1-3 %. In practice, a low sensitivity for small helium concentration has to be noted. To cope with this task, a method for selective hydrogen pressure reduction has been developed. Experimental investigations and calculations show that small helium amounts (about 1 %) in a hydrogen atmosphere can be analyzed with an accuracy of 3 - 10 %. Finally, this work deals with the effects of the measuring and calibration error on the resulting error in spectrum decomposition. This aspect has been investigated both in general mass-spectrometric gas analysis and in the analysis of hydrogen-helium-mixtures by means of the vector mass spectrometry. (author)

  13. Spectrometric properties and radiation damage of BGO crystals

    Science.gov (United States)

    Kim, Gen C.; Gasanov, Eldar M.

    1997-07-01

    Spectrometric properties, such as light output, energy resolution BGO crystals before and after (superscript 60)Co gamma-ray (dose 10(superscript 4) - 10(superscript 6) R) and neutron irradiation (fluence 10(superscript 14) cm(superscript -2)) are investigated. Condition for degradation of spectrometric properties and their recovering after irradiation are studied. The energy spectrum of the photons emitted from BGO crystals irradiated with neutron fluence contains the long living background peak which is caused by self-irradiation with radioactive isotopes produced in the crystals. The defect production was studied in crystals under the high dose gamma-irradiation with (superscript 60)Co isotope. It was found that after doses above 10(superscript 8) R the color center at 365 nm and doses higher than 10(superscript 9) R a wide absorption band in the region of 300 - 350 nm occur. Comparison of these results with those of reactor irradiation has shown that under the high dose gamma-irradiation the structure defect production takes place.

  14. Mass spectrometric detection of radiocarbon for dating applications

    Energy Technology Data Exchange (ETDEWEB)

    Synal, H.-A., E-mail: synal@phys.ethz.ch [ETH Zurich, Laboratory of Ion Beam Physics, Building HPK, 8093 Zurich (Switzerland); Schulze-Koenig, T.; Seiler, M.; Suter, M.; Wacker, L. [ETH Zurich, Laboratory of Ion Beam Physics, Building HPK, 8093 Zurich (Switzerland)

    2013-01-15

    Radiocarbon is still the most important nuclide measured by accelerator mass spectrometry (AMS). The related capabilities for dating and tracer studies are eminent not only in archaeology but also drive important applications in the earth and environmental sciences as well as in biomedical research. So far, standard mass spectrometric systems have not been capable of radiocarbon dating because of interfering molecular isobars which, however, can be completely eliminated in charge changing processes at high ion beam energies (MeV) [1,2]. Here, we present a novel type mass spectrometry system for radiocarbon analyses. Radiocarbon dating was performed using 45 keV {sup 14}C ions from the ion source and a molecule dissociation unit kept at ground potential. This proof-of-principle experiment demonstrates for the first time the feasibility of mass spectrometric radiocarbon dating without an accelerator. The results obtained will be the basis of an optimized design for a radiocarbon dating instrument comparable in size, complexity and cost to standard mass spectrometers.

  15. Mass spectrometric detection of radiocarbon for dating applications

    International Nuclear Information System (INIS)

    Synal, H.-A.; Schulze-König, T.; Seiler, M.; Suter, M.; Wacker, L.

    2013-01-01

    Radiocarbon is still the most important nuclide measured by accelerator mass spectrometry (AMS). The related capabilities for dating and tracer studies are eminent not only in archaeology but also drive important applications in the earth and environmental sciences as well as in biomedical research. So far, standard mass spectrometric systems have not been capable of radiocarbon dating because of interfering molecular isobars which, however, can be completely eliminated in charge changing processes at high ion beam energies (MeV) [1,2]. Here, we present a novel type mass spectrometry system for radiocarbon analyses. Radiocarbon dating was performed using 45 keV 14 C ions from the ion source and a molecule dissociation unit kept at ground potential. This proof-of-principle experiment demonstrates for the first time the feasibility of mass spectrometric radiocarbon dating without an accelerator. The results obtained will be the basis of an optimized design for a radiocarbon dating instrument comparable in size, complexity and cost to standard mass spectrometers.

  16. Mass spectrometric detection of radiocarbon for dating applications

    Science.gov (United States)

    Synal, H.-A.; Schulze-König, T.; Seiler, M.; Suter, M.; Wacker, L.

    2013-01-01

    Radiocarbon is still the most important nuclide measured by accelerator mass spectrometry (AMS). The related capabilities for dating and tracer studies are eminent not only in archaeology but also drive important applications in the earth and environmental sciences as well as in biomedical research. So far, standard mass spectrometric systems have not been capable of radiocarbon dating because of interfering molecular isobars which, however, can be completely eliminated in charge changing processes at high ion beam energies (MeV) [1,2]. Here, we present a novel type mass spectrometry system for radiocarbon analyses. Radiocarbon dating was performed using 45 keV 14C ions from the ion source and a molecule dissociation unit kept at ground potential. This proof-of-principle experiment demonstrates for the first time the feasibility of mass spectrometric radiocarbon dating without an accelerator. The results obtained will be the basis of an optimized design for a radiocarbon dating instrument comparable in size, complexity and cost to standard mass spectrometers.

  17. From the coupling between ion beam analysis techniques and physico-chemical characterization methods to the study of irradiation effects on materials behaviour; Du couplage des techniques d'analyse par faisceaux d'ions et des methodes de caracterisation physico-chimique a l'etude des effets d'irradiation sur le comportement des materiaux

    Energy Technology Data Exchange (ETDEWEB)

    Millard-Pinard, N

    2003-07-01

    The general purpose of my research work is to follow and to interpret the surface evolution of materials, which have received several treatments. During my PhD and my post-doc work, my field of research was tribology. Since I arrived in the 'Aval du Cycle Electronucleaire' group of the Institut de Physique Nucleaire de Lyon, my research activities are in line with the CNRS program 'PACE ' (Programme sur l'Aval du Cycle Electronucleaire) within the ACTINET network. They are coordinated by the PARIS (Physico-chimie des actinides et autres radioelements en solution et aux interfaces) and NOMADE (NOuveaux MAteriaux pour les DEchets) GDR with ANDRA (Agence Nationale pour la gestion des Dechets RAdioactifs), EDF and IRSN (Institut de Radioprotection et de Surete Nucleaire) as partner organisations. My work focused on the study of fission products and actinides migration in barrier materials, which may be capable of assuring the long term safety of deep geological repositories. Until now, it was necessary to use the coupling of ion beam analysis techniques and physico-chemical characterization techniques. During the last few months, I have became interested in understanding radiolytic effects. This new orientation has led us to use ion beams as an irradiating tool. These irradiation experiments are pursued in three major projects. The study of cobalt sulfide inhibition effects of radiolysis gas production during the irradiation of model organic molecules. This is a collaboration with the IRSN, the Institut de Recherche sur la Catalyse and the Ecole Nationale Superieure des Mines de Saint-Etienne. A PhD, co-directed by M. Pijolat from ENSMSE and myself, concerning this study will start in October 2003. Water radiolysis effects on iron corrosion are also studied in the particular case of vitrified nuclear waste containers, which will be stored in deep geological repositories. One ANDRA financed PhD, co-directed by Nathalie Moncoffre and myself, is dedicated to this study

  18. From the coupling between ion beam analysis techniques and physico-chemical characterization methods to the study of irradiation effects on materials behaviour; Du couplage des techniques d'analyse par faisceaux d'ions et des methodes de caracterisation physico-chimique a l'etude des effets d'irradiation sur le comportement des materiaux

    Energy Technology Data Exchange (ETDEWEB)

    Millard-Pinard, N

    2003-07-01

    The general purpose of my research work is to follow and to interpret the surface evolution of materials, which have received several treatments. During my PhD and my post-doc work, my field of research was tribology. Since I arrived in the 'Aval du Cycle Electronucleaire' group of the Institut de Physique Nucleaire de Lyon, my research activities are in line with the CNRS program 'PACE ' (Programme sur l'Aval du Cycle Electronucleaire) within the ACTINET network. They are coordinated by the PARIS (Physico-chimie des actinides et autres radioelements en solution et aux interfaces) and NOMADE (NOuveaux MAteriaux pour les DEchets) GDR with ANDRA (Agence Nationale pour la gestion des Dechets RAdioactifs), EDF and IRSN (Institut de Radioprotection et de Surete Nucleaire) as partner organisations. My work focused on the study of fission products and actinides migration in barrier materials, which may be capable of assuring the long term safety of deep geological repositories. Until now, it was necessary to use the coupling of ion beam analysis techniques and physico-chemical characterization techniques. During the last few months, I have became interested in understanding radiolytic effects. This new orientation has led us to use ion beams as an irradiating tool. These irradiation experiments are pursued in three major projects. The study of cobalt sulfide inhibition effects of radiolysis gas production during the irradiation of model organic molecules. This is a collaboration with the IRSN, the Institut de Recherche sur la Catalyse and the Ecole Nationale Superieure des Mines de Saint-Etienne. A PhD, co-directed by M. Pijolat from ENSMSE and myself, concerning this study will start in October 2003. Water radiolysis effects on iron corrosion are also studied in the particular case of vitrified nuclear waste containers, which will be stored in deep geological repositories. One ANDRA financed PhD, co-directed by Nathalie Moncoffre and myself, is

  19. Carbon nanotubes as solid-phase extraction sorbents prior to atomic spectrometric determination of metal species: A review

    Energy Technology Data Exchange (ETDEWEB)

    Herrero Latorre, C., E-mail: carlos.herrero@usc.es [Universidad de Santiago de Compostela, Dpto. Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Alfonso X el Sabio s/n, 27002 Lugo (Spain); Alvarez Mendez, J.; Barciela Garcia, J.; Garcia Martin, S.; Pena Crecente, R.M. [Universidad de Santiago de Compostela, Dpto. Quimica Analitica, Nutricion y Bromatologia, Facultad de Ciencias, Alfonso X el Sabio s/n, 27002 Lugo (Spain)

    2012-10-24

    Highlights: Black-Right-Pointing-Pointer The use of CNTs as sorbent for metal species in solid phase extraction has been described. Black-Right-Pointing-Pointer Physical and chemical strategies for functionalization of carbon nanotubes have been discussed. Black-Right-Pointing-Pointer Published analytical methods concerning solid phase extraction and atomic spectrometric determination have been reviewed. - Abstract: New materials have significant impact on the development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes - due to their high adsorption and desorption capacities - have been employed as sorption substrates in solid-phase extraction for the preconcentration of metal species from diverse matrices. Looking for successive improvements in sensitivity and selectivity, in the past few years, carbon nanotubes have been utilized as sorbents for solid phase extraction in three different ways: like as-grown, oxidized and functionalized nanotubes. In the present paper, an overview of the recent trends in the use of carbon nanotubes for solid phase extraction of metal species in environmental, biological and food samples is presented. The determination procedures involved the adsorption of metals on the nanotube surface, their quantitative desorption and subsequent measurement by means of atomic spectrometric techniques such as flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry/mass spectrometry, among others. Synthesis, purification and types of carbon nanotubes, as well as the diverse chemical and physical strategies for their functionalization are described. Based on 140 references, the performance and general properties of the applications of solid phase extraction based on carbon nanotubes for metal species atomic spectrometric determination are discussed.

  20. Carbon nanotubes as solid-phase extraction sorbents prior to atomic spectrometric determination of metal species: A review

    International Nuclear Information System (INIS)

    Herrero Latorre, C.; Álvarez Méndez, J.; Barciela García, J.; García Martín, S.; Peña Crecente, R.M.

    2012-01-01

    Highlights: ► The use of CNTs as sorbent for metal species in solid phase extraction has been described. ► Physical and chemical strategies for functionalization of carbon nanotubes have been discussed. ► Published analytical methods concerning solid phase extraction and atomic spectrometric determination have been reviewed. - Abstract: New materials have significant impact on the development of new methods and instrumentation for chemical analysis. From the discovery of carbon nanotubes in 1991, single and multi-walled carbon nanotubes – due to their high adsorption and desorption capacities – have been employed as sorption substrates in solid-phase extraction for the preconcentration of metal species from diverse matrices. Looking for successive improvements in sensitivity and selectivity, in the past few years, carbon nanotubes have been utilized as sorbents for solid phase extraction in three different ways: like as-grown, oxidized and functionalized nanotubes. In the present paper, an overview of the recent trends in the use of carbon nanotubes for solid phase extraction of metal species in environmental, biological and food samples is presented. The determination procedures involved the adsorption of metals on the nanotube surface, their quantitative desorption and subsequent measurement by means of atomic spectrometric techniques such as flame atomic absorption spectrometry, electrothermal atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry/mass spectrometry, among others. Synthesis, purification and types of carbon nanotubes, as well as the diverse chemical and physical strategies for their functionalization are described. Based on 140 references, the performance and general properties of the applications of solid phase extraction based on carbon nanotubes for metal species atomic spectrometric determination are discussed.

  1. Mass Spectrometric Identification and Differentiation of Botulinum Neurotoxins through Toxin Proteomics.

    Science.gov (United States)

    Kalb, Suzanne R; Barr, John R

    2013-08-01

    Botulinum neurotoxins (BoNTs) cause the disease botulism, which can be lethal if untreated. There are seven known serotypes of BoNT, A-G, defined by their response to antisera. Many serotypes are distinguished into differing subtypes based on amino acid sequence and immunogenic properties, and some subtypes are further differentiated into toxin variants. Toxin characterization is important as different types of BoNT can respond differently to medical countermeasures for botulism, and characterization of the toxin can aid in epidemiologic and forensic investigations. Proteomic techniques have been established to determine the serotype, subtype, or toxin variant of BoNT. These techniques involve digestion of the toxin into peptides, tandem mass spectrometric (MS/MS) analysis of the peptides, and database searching to identify the BoNT protein. These techniques demonstrate the capability to detect BoNT and its neurotoxin-associated proteins, and differentiate the toxin from other toxins which are up to 99.9% identical in some cases. This differentiation can be accomplished from toxins present in a complex matrix such as stool, food, or bacterial cultures and no DNA is required.

  2. Contribution to the study of the sintering of ex-carbonyl iron in the {alpha} and {gamma} phases using the micro-fractographic technique; Contribution a l'etude du frittage du fer ex-carbonyle en phases {alpha} et {gamma} par examen des surfaces de rupture au microscope electronique

    Energy Technology Data Exchange (ETDEWEB)

    Oxley Gaborit de Montjou, M.Th. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    The micro-fractographic study of the sintering of ex-carbonyl iron has shown or confirmed a number of phenomena of which the principal are as followed: Sintering in the a phase: -) existence of two stages of sintering differentiated by the type of rupture (inter or trans-crystalline); -) marked influence of the content of oxygen in the atmosphere and in the initial compressed sample on the speed of sintering; -) formation of striations on the grain-boundary surfaces and on the inner surface of pores caused by the presence of oxygen. Sintering in the {gamma} phase: -) a pronounced decrease in the speed of sintering: the grains in the initial powder remain in the granular state within the final {alpha} crystal in the iron sintered in the lower {gamma} range even after several hours of sintering; -) this granular structure can be eliminated by intermediate compression thus enabling the sintering process to proceed. A considerable decrease in the speed of sintering if the A{sub 3} point is passed one or more times in the {alpha} range sintering. A high speed sintering if the treatment in the {gamma} range is carried out at or above 1300 C. The results of this study agree with micrographic investigation as well as with dilatometric measurements and known auto-diffusion coefficients. (author) [French] L'etude microfractographique du frittage du fer ex-carbonyle a permis de mettre en evidence ou verifier plusieurs phenomenes dont les principaux sont les suivants: Pour le frittoge en phase {alpha}: -) existence de deux stades de frittage differencies par le type de rupture (inter et transcristalline); -) importance de la teneur en oxygene dans l'atmosphere et dans le comprime initial sur la vitesse de frittage; -) formation de stries dues a la presence d'oxygene sur les plans de joints et a l'interieur des pores. Pour le frittage en phase {gamma}: -) un ralentissement tres prononce de la cinetique du frittage: les granules de la poudre initiale demeurent a l'etat de

  3. A Theoretical and Experimental Study of the Subtraction of Two Scintigraphic Images - As Applied to Visualization of the Pancreas; Etude Theorique et Experimentale de la Soustraction de Deux Images Scintigraphiques

    Energy Technology Data Exchange (ETDEWEB)

    Desgrez, A.; Razafindramamba, V.; Saint-Laurent, J. de; Kellershohn, C. [CEA, Service Hospitalier Frederic Joliot, Orsay (France)

    1969-05-15

    Some scintigraphic studies are limited because the tissue being depicted is not selective with respect to the radioactive product available. For example, the radioactivity of the circulating blood interferes with mercury scanning of bucco-pharyngeal tumours. Scintigraphy of the pancreas is likewise impeded by localization of selenomethionine in the liver. Similarly, certain types of liver incorporation impair the visualization of insufficiency in the right kidney. One solution to this problem is to use two different labelled compounds to produce two images and then subtract one from the other so as to separate out the tissue to be depicted. The paper deals with the various problems involved in such subtraction. For example, exact spatial coincidence ofthedata to be subtracted can be ensured only by simultaneous recording of the two images; aconsecutive recording, even if it is fast, may be detrimental. The operation often consists in a double technique: suppression of the unwanted tissue by subtraction and amplification of the contrast between the tissue under investigation and residual background noise. These two operations, subtraction and amplification, relate to variable magnitudes; the resolution of the final image is thus a function of certain statistical parameters, which are also discussed. In studies carried out on the pancreas, attention is paid to the respective advantages and conditions of spectrometric separation of the various products which can be used for subtraction; the value of labelled rose bengal, which can also be used for eliminating certain intestinal loops, is stressed. A description is given of two types of apparatus which can be used in making the subtraction. The first and cheaper device involves storing the data obtained on four-track magnetic tape; the second and more rapid method utilizes the memory of a 4096-channel analyser. With both of these devices it is possible to make several subtractions during a single examination and the

  4. Mineralogical and physico-chemical study of slags from municipal wastes incineration with a view to a use in road making technique; Etude mineralogique et physico-chimique des machefers d'incineration des ordures menageres (M.I.O.M.) en vue d'une utilisation en technique routiere

    Energy Technology Data Exchange (ETDEWEB)

    Delville, N.

    2003-01-01

    The evolution of waste management regulations now urges to valorize the slags resulting from municipal wastes incineration. However, their long-term environmental and mechanical behaviour is not always well-controlled and some reserve still exist about their use in roadway techniques. A mineralogical and physico-chemical characterization of the slags from Rosiers d'Egletons has been carried out in order to determine the way of formation of their constituents and to understand their nature and evolution. These slags, assimilated to a D{sub 22} soil-type, can be used as backfilling or foundation layer material but their hydric characteristics make their comparison with natural soils delicate. It is a siliceous material (50%) containing calcium (15%), aluminium (10%), iron (7%) and sodium (6%) and characterized by a significant enrichment in lead, copper and zinc (x 100) but showing a satisfactory behaviour with respect to leaching. Its chemical behaviour does not change much with seasons and remains close to other French and European slags coming from grid furnaces. It is made of 35% of relict phases, 40% of primary phases and 25% of secondary phases. The heavy metals are distributed in these three families and with various shapes. An experimental study of the primary phases has permitted to establish a model of crystallisation at the equilibrium to which any slag can be compared in order to know its conditions of making inside the furnace. The high temperature blending present in the Rosiers d'Egletons slags come from the partial fusion of the wastes but are equivalent to experimental blending and seems to crystallize in reductive conditions. An experimental roadway has been made with the Rosiers d'Egletons slag as foundation bed and followed up during two years in order to study the mineralogical, chemical and geo-technical evolution of the material. No deformation of the roadway has been noticed and a hardening seems to develop with time. No noxious

  5. Mass spectrometer introduction line: application to the analysis of impurities in uranium hexafluoride; Ligne d'introduction pour spectrometre de masse: application a l'analyse des impuretes contenues dans l'UF{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Besson, M. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement de physico-chimie, service des isotopes stables, section de spectrometrie de masse

    1967-01-01

    The continuous mass-spectrometric analysis of impurities in UF{sub 6} is possible industrially if certain conditions imposed by the nature of the gas are respected. The gas introduction line arriving at the spectrometer's source makes it possible to fix the flow-rate, to control the inlet pressure and to selectively destroy the gas containing the impurities. The operational conditions for the line are defined and a description is given of the theoretical and experimental study of the various elements of which it is composed, i.e. the leak valve, the flow-meter, the chemical trap and the servo-mechanism making it possible to regulate and control the gas flow. The dynamic characteristics of the line's various components and the performance of the equipment in the case of the analyses considered are given. (author) [French] L'analyse en continu par spectrometrie de masse des impuretes contenus dans l'UF{sub 6} est possible industriellement moyennant certaines conditions imposees par la nature du gaz. La ligne d'introduction des gaz dans la source du spectrometre permet de regler le debit, de controler la pression d'introduction et de detruire selectivement le gaz porteur d'impuretes. Les conditions de fonctionnement de la ligne etant definies, on decrit l'etude theorique et experimentale des differents elements qui la composent, c'est-a-dire: le robinet a fuite, le debitmetre, le piege chimique et l'ensemble d'asservissement permettant la regulation et le controle du debit. On donne les caracteristiques dynamiques des differents constituants de la ligne et les performances de l'ensemble pour les analyses considerees. (auteur)

  6. Mass spectrometer introduction line: application to the analysis of impurities in uranium hexafluoride; Ligne d'introduction pour spectrometre de masse: application a l'analyse des impuretes contenues dans l'UF{sub 6}

    Energy Technology Data Exchange (ETDEWEB)

    Besson, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement de physico-chimie, service des isotopes stables, section de spectrometrie de masse

    1967-01-01

    The continuous mass-spectrometric analysis of impurities in UF{sub 6} is possible industrially if certain conditions imposed by the nature of the gas are respected. The gas introduction line arriving at the spectrometer's source makes it possible to fix the flow-rate, to control the inlet pressure and to selectively destroy the gas containing the impurities. The operational conditions for the line are defined and a description is given of the theoretical and experimental study of the various elements of which it is composed, i.e. the leak valve, the flow-meter, the chemical trap and the servo-mechanism making it possible to regulate and control the gas flow. The dynamic characteristics of the line's various components and the performance of the equipment in the case of the analyses considered are given. (author) [French] L'analyse en continu par spectrometrie de masse des impuretes contenus dans l'UF{sub 6} est possible industriellement moyennant certaines conditions imposees par la nature du gaz. La ligne d'introduction des gaz dans la source du spectrometre permet de regler le debit, de controler la pression d'introduction et de detruire selectivement le gaz porteur d'impuretes. Les conditions de fonctionnement de la ligne etant definies, on decrit l'etude theorique et experimentale des differents elements qui la composent, c'est-a-dire: le robinet a fuite, le debitmetre, le piege chimique et l'ensemble d'asservissement permettant la regulation et le controle du debit. On donne les caracteristiques dynamiques des differents constituants de la ligne et les performances de l'ensemble pour les analyses considerees. (auteur)

  7. Studies of magnetism with inelastic scattering of cold neutrons; Etudes de magnetisme realisees a l'aide de la diffusion inelastique de neutrons froids

    Energy Technology Data Exchange (ETDEWEB)

    Jacrot, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    Inelastic scattering of cold neutrons can be used to study some aspects of magnetism: spins waves, exchange integrals, vicinity of Curie point. After description of the experimental set-up, several experiments, in the fields mentioned above, are analysed. (author) [French] La technique de diffusion inelastique des neutrons froids est utilisee pour etudier certains aspects du magnetisme: ondes de spins, integrales d'echange, etude au voisinage du point de Curie, etc. Apres une description de l'appareillage, on analyse diverses experiences effectuees dans les domaines enumeres plus haut. (auteur)

  8. Probes and their application to the study of H.F. plasmoids; Les sondes et leur application dans l'etude des plasmoides H.F

    Energy Technology Data Exchange (ETDEWEB)

    Brunet, A; Geller, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    In the first part of this paper, we study the single Langmuir probe and the double-probe method. In the second part, we describe the probe-technique in connection with R.F. plasmoids. (author) [French] Dans la premiere partie de cet article, nous rappelons les principes d'utilisation de la sonde simple de Langmuir ainsi que la methode de la sonde double. La seconde partie est consacree a la pratique des sondes dans l'etude des plasmoides H.F. (auteur)

  9. The theoretical study of full spectrum analysis method for airborne gamma-ray spectrometric data

    International Nuclear Information System (INIS)

    Ni Weichong

    2011-01-01

    Spectra of airborne gamma-ray spectrometry was found to be the synthesis of spectral components of radioelement sources by analyzing the constitution of radioactive sources for airborne gamma-ray spectrometric survey and establishing the models of gamma-ray measurement. The mathematical equation for analysising airborne gamma-ray full spectrometric data can be expressed into matrix and related expansions were developed for the mineral resources exploration, environmental radiation measurement, nuclear emergency monitoring, and so on. Theoretical study showed that the atmospheric radon could be directly computed by airborne gamma-ray spectrometric data with full spectrum analysis without the use of the accessional upward-looking detectors. (authors)

  10. Liquid chromatography/mass spectrometric determination of patulin in apple juice using atmospheric pressure photoionization.

    Science.gov (United States)

    Takino, Masahiko; Daishima, Shigeki; Nakahara, Taketoshi

    2003-01-01

    This paper describes a comparison between atmospheric pressure chemical ionization (APCI) and the recently introduced atmospheric pressure photoionization (APPI) technique for the liquid chromatography/mass spectrometric (LC/MS) determination of patulin in clear apple juice. A column switching technique for on-line extraction of clear apple juice was developed. The parameters investigated for the optimization of APPI were the ion source parameters fragmentor voltage, capillary voltage, and vaporizer temperature, and also mobile phase composition and flow rate. Furthermore, chemical noise and signal suppression of analyte signals due to sample matrix interference were investigated for both APCI and APPI. The results indicated that APPI provides lower chemical noise and signal suppression in comparison with APCI. The linear range for patulin in apple juice (correlation coefficient >0.999) was 0.2-100 ng mL(-1). Mean recoveries of patulin in three apple juices ranged from 94.5 to 103.2%, and the limit of detection (S/N = 3), repeatability and reproducibility were 1.03-1.50 ng mL(-1), 3.9-5.1% and 7.3-8.2%, respectively. The total analysis time was 10.0 min. Copyright 2003 John Wiley & Sons, Ltd.

  11. Mass spectrometric study of vaporization of cesium tellurate and tellurite

    International Nuclear Information System (INIS)

    Semenov, G.A.; Fokina, L.A.; Mouldagalieva, R.A.

    1994-01-01

    The process of vaporization of cesium tellurate and tellurite was studied by the Knudsen effusion method with a mass spectrometric analysis of the vapor composition. The thermal dissociation of Cs 2 TeO 4 to Cs 2 TeO 3 and the congruent vaporization of Cs 2 TeO 3 were established. Thermodynamic functions for gaseous Cs 2 TeO 3 have been calculated. The standard enthalpy of sublimation Δ s H (298.15)=268.1±13.0 kJ mol -1 was determined by the 2nd and 3rd laws of thermodynamics. The enthalpy of formation Δ f H (298.15)=-725.1±13.0 kJ mol -1 for gaseous Cs 2 TeO 3 and the enthalpy of atomization Δ at H (298.15)=1841.3±15.0 kJ mol -1 have been computed. ((orig.))

  12. Modern spectrometric methods for the analysis of labelled compounds

    International Nuclear Information System (INIS)

    Kaspersen, F.M.; Funke, C.W.; Wagenaars, G.N.; Jacobs, P.L.

    1988-01-01

    A proper analysis of chemical compounds should give information about the chemical identity (not only the structure but also enantiomeric form), the chemical purity and chemical composition (e.g. giving information about counter-ions, solvents of crystallization). For labelled compounds information is also needed about isotopic purity (defined as the % of isotope present in the compound), the position/distribution of the isotope in the molecule and degree of labelling/specific activity. In the past ten years the possibilities for spectrometric analyses of labelled compounds have increased enormously and this chapter will give an overview of these methods with the exception of (radio)chromatography that will be dealt with in another chapter. (author)

  13. X-ray fluorescence spectrometric and optical emission spectographic analysis of thoria in thoriated copper metal powder

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.

    1984-01-01

    Two methods, one using the X-ray fluorescence (XRF) spectrometric technique and another using optical emission spectrographic (OES) technique are described for the determination of thoria in the concentration range 0.5-10% in thoriated copper metal powder. The precision of XRF method is superior to OES method but when sample quantity is very small, the OES method is useful. For XRF method, 500 mg sample is mixed with boric acid binding material and converted to a tablet for analysis. For OES method, only 200 mg sample is needed which is glued to the flat ends of two graphite electrodes for excitation by AC arc. The precision obtained in XRF is better than +-1% and in OES it is +-23%. (author)

  14. Study of the age of uranium-containing mineral deposits in the Limouzat, the bois-noir mountains (12963); Etude des ages des mineralisations uraniferes du gisement du Limouzat, Massif des bois-noirs (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Durand, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The present work is concerned with 7 different samples taken at various levels in the Limouzat mine in the Bois-Noirs mountains. It has been possible to show that the uranium dates from 265 M.Y. and that a rearrangement occurred 65 M.Y. ago. A {gamma}-spectrometer study which was originally intended to show the existence of the lack of balance in the radon circulation, has made it possible to show that the {gamma} spectra recorded on various samples could be erroneous. We observed in effect that the presence of lead, iron, etc., had a strong influence on the {gamma} spectrum of the radium family, whereas all research workers have considered that concentrations in the uranium ore were negligible and had no significant effect on the study of the {gamma} spectra of the samples. It is obvious that an interesting study has to be undertaken on the screen effects of the different cations existing in the ores. We believe that it is possible to show the presence of certain elements directly by {gamma}-spectrometry. The ages measured with the mass spectrometer present two types of disagreement but these have been explained by considering that there occurred a first arrival of lead followed by a rearrangement and, at certain points, a second arrival at this date. Finally, the deposit studied undergoes a circulation of uranium and of radon. (author) [French] La presente etude a porte sur 7 prelevements differents effectues a divers niveaux de la mine du Limouzat, massif des Bois-Noirs. Elle a permis de mettre en evidence une premiere venue d'uranium il y a 265 M.A., suivie d'un remaniements il y a 65 M.A. Une etude au spectrometre {gamma} destinee, a l'origine, a prouver les desequilibres dus aux circulations de radon a permis de montrer que les spectres {gamma} enregistres sur divers echantillons pouvaient etre entaches d'erreurs. Nous nous sommes apercus en effet que la presence de plomb, de fer..., avait une forte influence sur le spectre {gamma} de la famille du radium

  15. Dosimeter calibration facilities and methods at the Radiation Measurement Laboratory of the Centre d'etudes nucleaires, Grenoble

    International Nuclear Information System (INIS)

    Choudens, H. de; Herbaut, Y.; Haddad, A.; Giroux, J.; Rouillon, J.; CEA Centre d'Etudes Nucleaires de Grenoble, 38

    1975-01-01

    At the Centre d'etudes nucleaires, Grenoble, the Radiation Measurement Laboratory, which forms part of the Environmental Protection and Research Department, serves the entire Centre for purposes of dosimetry and the calibration of dose meters. The needs of radiation protection are such that one must have facilities for checking periodically the calibration of radiation-monitoring instruments and developing special dosimetry techniques. It was thought a good idea to arrange for the dosimetry and radiation protection team to assist other groups working at the Centre - in particular, the staff of the biology and radiobiology laboratories - and also bodies outside the framework of the French Commissariat a l'energie atomique. Thus, technical collaboration has been established with, for example, Grenoble's Centre hospitalier universitaire (university clinic), which makes use of the facilities and skills available at the Radiation Measurement Laboratory for solving special dosimetry problems. With the Laboratory's facilities it is possible to calibrate dose meters for gamma, beta and neutron measurements

  16. Mass spectrometric identification of isoforms of PR proteins in xylem sap of fungus-infected tomato

    NARCIS (Netherlands)

    Rep, Martijn; Dekker, Henk L.; Vossen, Jack H.; de Boer, Albert D.; Houterman, Petra M.; Speijer, Dave; Back, Jaap W.; de Koster, Chris G.; Cornelissen, Ben J. C.

    2002-01-01

    The protein content of tomato (Lycopersicon esculentum) xylem sap was found to change dramatically upon infection with the vascular wilt fungus Fusarium oxysporum. Peptide mass fingerprinting and mass spectrometric sequencing were used to identify the most abundant proteins appearing during

  17. Study of radio-active ions in the atmosphere; Etude des ions radioactifs de l'atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Renoux, A [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-01-01

    A comparative study is made of active, deposits of radon and thoron in suspension in the atmosphere by means of {alpha} radiation counting, using ZELENY tubes, scattering equipment, filter papers or membranes. It has been possible to show the existence of small and large ions which are negative and positive, as well as of neutral radio-active nuclei; their properties are studied. A theoretical interpretation of the results is presented. The average content of radon (using the Ra A concentration) and of Th B in the air has been determined. The radioactive equilibrium between radon and its daughter products in atmospheric air are examined. The techniques developed for active radon and thoron deposits are applied to the study of artificial radio-activity, the analyses being carried out by means of {gamma} spectrometry. (author) [French] On effectue une etude comparative entre les depots actifs du radon et du thoron en suspension dont l'atmosphere a l'aide de comptages de rayonnement {alpha}, en utilisant des tubes de ZELENY, une batterie de diffusion, des papiers filtres ou des membranes. On met ainsi en evidence la presence de petits et gros ions negatifs et positifs, ainsi que celle de noyaux neutres radioactifs, et on etudie leurs proprietes. Une Interpretation theorique des resultats obtenus est developpee. On determine la teneur moyenne de l'air en radon (a partir de la concentration en Ra A) et en Th B. L'equilibre radioactif entre le radon et ses descendants, dans l'air atmospherique, est examine. Les Techniques mises au point pour les depots actifs du radon et du thoron sont appliquees a l'etude de la radioactivite artificielle, les depouillements s'effectuant par spectrometrie {gamma}. (auteur)

  18. The use radioactive tracers in the study of solid transport in water streams; Emploi de traceurs radioactifs pour l'etude du transport solide dans les cours d'eau

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Jaffry, P; Heuzel, M [Laboratoire National d' Hydraulique de Chatou, 78 (France)

    1960-07-01

    The Laboratoire National d'Hydraulique which has been studying, during the last few years in conjunction with the Centre d'Etudes Nucleaires at Saclay, the development of apparatus and of methods of investigation of sediment transport by radioactive tracer techniques, is at the moment trying to perfect a genuinely quantitative method of investigation. Two experiments have recently been carried out in rivers, the first designed to investigate the transport of pebbles in the river Rhone, the other to investigate the movement of sands in the Niger. This second experiment has been supported by parallel experiments carried out on a reduced scale model of the Niger built at the laboratories of Chatou: in this experiment are used the radiation from {sup 56}Mn and {sup 24}Na obtained by direct activation of the crushed apricot store which represents, in the scale model, the natural sediment on the bed of the Niger. The combined efforts of the laboratories of Chatou and of the Centre d'Etudes Nucleaires at Saclay are at the moment directed to the application of radioactive tracers to studies on the scale models with the double aim: a) of having a single investigational method for the actual experiment and for the model making it possible to control the accuracy of the model in the preliminary stage of calibrating this model; b) of making the most of the possibilities of observation and of direct measurement offered by the scale models for studying the possibility of improving the tracer method, in particular with respect to the collecting of quantitative data. (author) [French] La Laboratoire National d'Hydraulique qui, depuis quelques annees a developpe, en collaboration avec le Centre d'Etudes Nucleaires de Saclay, les appareillages et les techniques d'etudes des mouvements de sediments par la methode des traceurs radioactifs, s'efforce actuellement de mettre au point un moyen d'investigation veritablement quantitatif. Deux experiences ont ete effectuees recemment en

  19. Resolution of a protein sequence ambiguity by X-ray crystallographic and mass spectrometric methods

    International Nuclear Information System (INIS)

    Keefe, L.J.; Lattman, E.E.; Wolkow, C.; Woods, A.; Chevrier, M.; Cotter, R.J.

    1992-01-01

    Ambiguities in amino acid sequences are a potential problem in X-ray crystallographic studies of proteins. Amino acid side chains often cannot be reliably identified from the electron density. Many protein crystal structures that are now being solved are simple variants of a known wild-type structure. Thus, cloning artifacts or other untoward events can readily lead to cases in which the proposed sequence is not correct. An example is presented showing that mass spectrometry provides an excellent tool for analyzing suspected errors. The X-ray crystal structure of an insertion mutant of Staphylococcal nuclease has been solved to 1.67 A resolution and refined to a crystallographic R value of 0.170. A single residue has been inserted in the C-terminal α helix. The inserted amino acid was believed to be an alanine residue, but the final electron density maps strongly indicated that a glycine had been inserted instead. To confirm the observations from the X-ray data, matrix-assisted laser desorption mass spectrometry was employed to verify the glycine insertion. This mass spectrometric technique has sufficient mass accuracy to detect the methyl group that distinguishes glycine from alanine and can be extended to the more common situation in which crystallographic measurements suggest a problem with the sequence, but cannot pinpoint its location or nature. (orig.)

  20. Resolution of a protein sequence ambiguity by X-ray crystallographic and mass spectrometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Keefe, L.J.; Lattman, E.E. (Dept. of Biophysics and Biophysical Chemistry, Johns Hopkins Univ. School of Medicine, Baltimore, MD (United States)); Wolkow, C.; Woods, A.; Chevrier, M.; Cotter, R.J. (Middle Atlantic Mass Spectrometry Lab., Johns Hopkins Univ. School of Medicine, Baltimore, MD (United States))

    1992-04-01

    Ambiguities in amino acid sequences are a potential problem in X-ray crystallographic studies of proteins. Amino acid side chains often cannot be reliably identified from the electron density. Many protein crystal structures that are now being solved are simple variants of a known wild-type structure. Thus, cloning artifacts or other untoward events can readily lead to cases in which the proposed sequence is not correct. An example is presented showing that mass spectrometry provides an excellent tool for analyzing suspected errors. The X-ray crystal structure of an insertion mutant of Staphylococcal nuclease has been solved to 1.67 A resolution and refined to a crystallographic R value of 0.170. A single residue has been inserted in the C-terminal {alpha} helix. The inserted amino acid was believed to be an alanine residue, but the final electron density maps strongly indicated that a glycine had been inserted instead. To confirm the observations from the X-ray data, matrix-assisted laser desorption mass spectrometry was employed to verify the glycine insertion. This mass spectrometric technique has sufficient mass accuracy to detect the methyl group that distinguishes glycine from alanine and can be extended to the more common situation in which crystallographic measurements suggest a problem with the sequence, but cannot pinpoint its location or nature. (orig.).

  1. Mass spectrometric investigation of neutral and charged constituents in saturated vapor over PrI3

    International Nuclear Information System (INIS)

    Motalov, V.B.; Vorobiev, D.E.; Kudin, L.S.; Markus, T.

    2009-01-01

    The Knudsen effusion mass spectrometric technique was used to study vapor species over praseodymium triiodide. The monomer, PrI 3 , and dimer, Pr 2 I 6 , molecules and the negative ions, PrI 4 - and Pr 2 I 7 - , were observed in saturated vapor in the temperature range from 856 K to 1048 K. The partial vapor pressures of neutral constituents were determined and the enthalpies of sublimation obtained using the second and the third laws of thermodynamics (Δ s H deg. (298.15 K) = 291 ± 4 kJ mol -1 for PrI 3 , and Δ s H deg. (298.15 K) = 400 ± 30 kJ mol -1 for Pr 2 I 6 ). The equilibrium constants for various ion molecular reactions were measured and the enthalpies of reactions obtained. The enthalpies of formation, Δ f H deg. (298.15 K) kJ mol -1 , of gaseous molecules and ions were calculated and are as follows: -374 ± 6 (PrI 3 ), -929 ± 30 (Pr 2 I 6 ), -867 ± 30 (PrI 4 - ), -1432 ± 50 (Pr 2 I 7 - )

  2. Spectroscopic and Spectrometric Methods Used for the Screening of Certain Herbal Food Supplements Suspected of Adulteration.

    Science.gov (United States)

    Mateescu, Cristina; Popescu, Anca Mihaela; Radu, Gabriel Lucian; Onisei, Tatiana; Raducanu, Adina Elena

    2017-06-01

    Purpose: This study was carried out in order to find a reliable method for the fast detection of adulterated herbal food supplements with sexual enhancement claims. As some herbal products are advertised as "all natural", their "efficiency" is often increased by addition of active pharmaceutical ingredients such as PDE-5 inhibitors, which can be a real health threat for the consumer. Methodes: Adulterants, potentially present in 50 herbal food supplements with sexual improvement claims, were detected using 2 spectroscopic methods - Raman and Fourier Transform Infrared - known for reliability, reproductibility, and an easy sample preparation. GC-MS technique was used to confirm the potential adulterants spectra. Results: About 22% (11 out of 50 samples) of herbal food supplements with sexual enhancement claims analyzed by spectroscopic and spectrometric methods proved to be "enriched" with active pharmaceutical compounds such as: sildenafil and two of its analogues, tadalafil and phenolphthalein. The occurence of phenolphthalein could be the reason for the non-relevant results obtained by FTIR method in some samples. 91% of the adulterated herbal food supplements were originating from China. Conclusion: The results of this screening highlighted the necessity for an accurate analysis of all alleged herbal aphrodisiacs on the Romanian market. This is a first such a screening analysis carried out on herbal food supplements with sexual enhancement claims.

  3. The interlaboratory experiment IDA-72 on mass spectrometric isotope dilution analysis. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Drosselmeyer, E.

    1975-07-01

    Within the framework of the Safeguards Project of the Federal Republic of Germany at the Nuclear Research Center Karlsruhe an analytical intercomparison program was carried out in cooperation with 22 laboratories of 13 countries or international organizations. The main objective was the acquisition of basic data on the errors involved in the mass spectrometric isotope dilution analysis if it is applied to the determination of uranium and plutonium in diluted active feed solutions of reprocessing plants in routine operation. The results were evaluated by statistical methods mainly in regard to the calculation of the estimates of the variances for the different error components contributing to the total error of this analytical technique. Furthermore, the performance of two new methods for sample conditioning suggested by the International Atomic Energy Agency, Vienna, and the European Institute for Transuranium Elements (EURATOM), Karlsruhe, was successfully tested. The results of some investigations on the stability of diluted high active feed solutions and on comparison analysis by X-ray fluorescence spectrometry are also included. Data on the analytical efforts (manhours) invested in this study are reported as well as general experiences made in the organization and performance of an experiment on such an extended international level. (orig.) [de

  4. Study of point defects in pure iron by means of electrical resistivity; Etude au moyen de la resistivite electrique des defauts ponctuels dans le fer pur

    Energy Technology Data Exchange (ETDEWEB)

    Minier-Cassayre, C [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-04-01

    In the first part of this work, after having reviewed the production, observation and the annealing of point defects In metals, we resume the present state of research. In the second part, we explain the techniques we have employed to produce point defects at low temperatures: irradiation, quenching and cold-work; and go on to the study of their migration and annealing. The experimental results obtained for pure iron and for iron containing certain impurities are presented in the third part. In the fourth part we suggest a model which explains the different stages of annealing observed, and their properties. We then compare the energies of interaction between point defects with the values deduced from the theory of elasticity. (author) [French] Dans la premiere partie de cette etude, apres avoir passe en revue la production, l'observation et les modes de guerison des defauts ponctuels dans les metaux, nous exposons l'etat actuel des recherches. La seconde partie est consacree aux techniques que nous avons employees pour produire des defauts ponctuels a basse temperature: irradiations, trempe et ecrouissage puis a l'etude de leur migration et de leur guerison. Les resultats experimentaux obtenus dans le fer pur et le fer contenant certaines impuretes sont presentes dans le troisieme chapitre. Nous proposons ensuite un modele qui explique les differents stades de guerison observes et leurs nombreuses proprietes: nous comparons les energies d'interaction entre defauts ponctuels aux valeurs que l'on pourrait deduire d'un modele elastique. (auteur)

  5. A novel mass spectrometric strategy "BEMAP" reveals Extensive O-linked protein glycosylation in Enterotoxigenic Escherichia coli

    DEFF Research Database (Denmark)

    Boysen, Anders; Palmisano, Giuseppe; Krogh, Thøger Jensen

    2016-01-01

    The attachment of sugars to proteins via side-chain oxygen atoms (O-linked glycosylation) is seen in all three domains of life. However, a lack of widely-applicable analytical tools has restricted the study of this process, particularly in bacteria. In E. coli, only four O-linked glycoproteins have...... previously been characterized. Here we present a glycoproteomics technique, termed BEMAP, which is based on the beta-elimination of O-linked glycans followed by Michael-addition of a phosphonic acid derivative, and subsequent titanium dioxide enrichment. This strategy allows site-specific mass......-spectrometric identification of proteins with O-linked glycan modifications in a complex biological sample. Using BEMAP we identified cell surface-associated and membrane vesicle glycoproteins from Enterotoxigenic E. coli (ETEC) and non-pathogenic E. coli K-12. We identified 618 glycosylated Serine and Threonine residues...

  6. Vitamin D-metabolites from human plasma and mass spectrometric analysis by fast heavy ion induced desorption

    Energy Technology Data Exchange (ETDEWEB)

    Fohlman, J; Peterson, P A [Uppsala Univ. (Sweden). Dept. of Cell Research; Kamensky, I; Hakansson, P; Sundqvist, B [Tandemacceleratorlaboratoriet, Uppsala (Sweden)

    1982-07-01

    D-vitamin metabolites have been isolated from human serum employing chromatographic techniques. The serum carrier protein for vitamin D (DBP) was first isolated by immunosorbent chromatography. Lipid ligands associated with DBP were then extracted with hexane and separated by high pressure liquid chromatography (HPLC). Detection of vitamin D metabolites by their absorbance of ultraviolet light is not sufficiently sensitive to monitor all vitamin D derivatives from a few millilitres of serum. Therefore, further analyses are necessary to quantitative these compounds. We have begun to develop a mass spectrometric method to achieve a reliable, quantitative procedure. As a first step towards this goal a number of pure samples of vitamin D compounds have been studied in a time-of-flight mass spectrometer based on fast heavy ion induced desorption. All vitamin D compounds examined could be detected and identified by their molecular ion and fragment spectra.

  7. Vitamin D-metabolites from human plasma and mass spectrometric analysis by fast heavy ion induced desorption

    International Nuclear Information System (INIS)

    Fohlman, J.; Peterson, P.A.

    1982-01-01

    D-vitamin metabolites have been isolated from human serum employing chromatographic techniques. The serum carrier protein for vitamin D (DBP) was first isolated by immunosorbent chromatography. Lipid ligands associated with DBP were then extracted with hexane and separated by high pressure liquid chromatography (HPLC). Detection of vitamin D metabolites by their absorbance of ultraviolet light is not sufficiently sensitive to monitor all vitamin D derivatives from a few millilitres of serum. Therefore, further analyses are necessary to quantitative these compounds. We have begun to develop a mass spectrometric method to achieve a reliable, quantitative procedure. As a first step towards this goal a number of pure samples of vitamin D compounds have been studied in a time-of-flight mass spectrometer based on fast heavy ion induced desorption. All vitamin D compounds examined could be detected and identified by their molecular ion and fragment spectra. (orig.)

  8. Mass spectrometric detection of proteins in non-aqueous media : the case of prion proteins in biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Douma, M.D.; Kerr, G.M.; Brown, R.S.; Keller, B.O.; Oleschuk, R.D. [Queen' s Univ., Kingston, ON (Canada). Dept. of Chemistry

    2008-08-15

    This paper presented a filtration method for detecting protein traces in non-aqueous media. The extraction technique used a mixture of acetonitrile, non-ionic detergent and water along with filter disks with embedded C{sub 8}-modified silica particles to capture the proteins from non-aqueous samples. The extraction process was then followed by an elution of the protein from the filter disk and direct mass spectrometric detection and tryptic digestion with peptide mapping and MS/MS fragmentation of protein-specific peptides. The method was used to detect prion proteins in spiked biodiesel samples. A tryptic peptide with the sequence YGQGSPGGNR was used for unambiguous identification. Results of the study showed that the method is suitable for the large-scale testing of protein impurities in tallow-based biodiesel production processes. 33 refs., 6 figs.

  9. Radio spectrometric survey of un-surveyed areas in Syria

    International Nuclear Information System (INIS)

    Aissa, M.; Al-Hent, R; Jubeli, Y.

    2002-11-01

    The values and distribution of the radioelements e U, e Th, % K and Ur units in the surface geological formations of the west and south sectors of Syrian region, were estimated using carbone gamma ray spectrometric survey. The radiometric maps were prepared, as well as, many geological profiles, cross sections studied in different locations and geochemical samples were analyzed by laboratory gamma ray spectrometry and by x-ray diffractometry, the results of the all sets were compared. In general, the survey shows, low radioelement concentrations in the area, especially on basic rocks (Jabal Al-arab, Hawran) south Syria, and on ultra basic rocks (ophiolitic complex) north-west Syria, but there are some separate anomalous spots were connected with phosphate rocks, detected on cretaceous and Palaeogene age. Some times we noticed high radioelement concentrations haloes associated with fractured zones were already arise from secondary uranium mineralization, as a result of solutions movement through fissures in carbonatic and/or chalk like limestone rocks. finally, the obtained concentrations, represent a background values which has no significant importance for uranium exploration point of view. (author)

  10. Study of natural diamond detector spectrometric properties under neutron irradiation

    CERN Document Server

    Alekseyev, A B; Kaschuck, Y; Krasilnikov, A; Portnov, D; Tugarinov, S

    2002-01-01

    Natural diamond detector (NDD) performance was studied up to a neutron fluence of 10 sup 1 sup 5 neutron/cm sup 2. The variations of the NDD spectrometric response to incident alpha-particles from sup 2 sup 4 sup 1 Am source after exposure to fast neutron fluences up to 3x10 sup 1 sup 6 n/cm sup 2 were examined. No significant variations up to the level of 10 sup 1 sup 4 n/cm sup 2 were observed. Degradation of charge collection efficiency at higher fluences is reported. No remarkable increase of the NDD leakage current and count rate change had been observed up to a neutron fluence of 3x10 sup 1 sup 6 n/cm sup 2. The charge collection efficiency variations of neutron irradiated diamond spectrometer were studied ex situ under gamma-rays, beta-radiation and visible light excitation. Charge collection efficiency restoration up to 75% level and the NDD performance stabilization by extrinsic low-intensity visible light (550 nm

  11. Functional proteomics with new mass spectrometric and bioinformatics tools

    International Nuclear Information System (INIS)

    Kesners, P.W.A.

    2001-01-01

    A comprehensive range of mass spectrometric tools is required to investigate todays life science applications and a strong focus is on addressing the needs of functional proteomics. Application examples are given showing the streamlined process of protein identification from low femtomole amounts of digests. Sample preparation is achieved with a convertible robot for automated 2D gel picking, and MALDI target dispensing. MALDI-TOF or ESI-MS subsequent to enzymatic digestion. A choice of mass spectrometers including Q-q-TOF with multipass capability, MALDI-MS/MS with unsegmented PSD, Ion Trap and FT-MS are discussed for their respective strengths and applications. Bioinformatics software that allows both database work and novel peptide mass spectra interpretation is reviewed. The automated database searching uses either entire digest LC-MS n ESI Ion Trap data or MALDI MS and MS/MS spectra. It is shown how post translational modifications are interactively uncovered and de-novo sequencing of peptides is facilitated

  12. Determination of iodine to compliment mass spectrometric measurements

    International Nuclear Information System (INIS)

    Hohorst, F.A.

    1994-11-01

    The dose of iodine-129 to facility personnel and the general public as a result of past, present, and future activities at DOE sites is of continuing interest, WINCO received about 160 samples annually in a variety of natural matrices, including snow, milk, thyroid tissue, and sagebrush, in which iodine-129 is determined in order to evaluate this dose, Currently, total iodine and the isotopic ratio of iodine-127 to iodine-129 are determined by mass spectrometry. These two measurements determine the concentration of iodine-129 in each sample, These measurements require at least 16 h of mass spectrometer operator time for each sample. A variety of methods are available which concentrate and determine small quantities of iodine. Although useful, these approaches would increase both time and cost. The objective of this effort was to determine total iodine by an alternative method in order to decrease the load on mass spectrometry by 25 to 50%. The preparation of each sample for mass spectrometric analysis involves a common step--collection of iodide on an ion exchange bed. This was the focal point of the effort since the results would be applicable to all samples

  13. Status of mass spectrometric radiocarbon detection at ETHZ

    Energy Technology Data Exchange (ETDEWEB)

    Seiler, Martin; Maxeiner, Sascha; Wacker, Lukas; Synal, Hans-Arno

    2015-10-15

    A prototype of a mass spectrometric radiocarbon detection instrument without accelerator stage was built for the first time and set into operation at ETH Zurich. The system is designed as an experimental platform to optimize performance of {sup 14}C detection at low ion energies and to study the most relevant processes that may limit system performance. The optimized stripper unit incorporates differential pumping to maintain a low gas outflow and a revised tube design to better match the phase space volume of the ion beam at low energies. The system is fully operational and has demonstrated true radiocarbon dating capabilities. The overall beam transmission through the stripper tube is about 40% for the 1{sup +} charge state. Radiocarbon analyses with an overall precision of 0.6% were obtained on a single sample under regular measurement conditions. By analyzing multiple targets of the same sample material an uncertainty level of 0.3% has been reached. The background level corresponds to a radiocarbon age of 40,000 years.

  14. Surface acoustic wave nebulization facilitating lipid mass spectrometric analysis.

    Science.gov (United States)

    Yoon, Sung Hwan; Huang, Yue; Edgar, J Scott; Ting, Ying S; Heron, Scott R; Kao, Yuchieh; Li, Yanyan; Masselon, Christophe D; Ernst, Robert K; Goodlett, David R

    2012-08-07

    Surface acoustic wave nebulization (SAWN) is a novel method to transfer nonvolatile analytes directly from the aqueous phase to the gas phase for mass spectrometric analysis. The lower ion energetics of SAWN and its planar nature make it appealing for analytically challenging lipid samples. This challenge is a result of their amphipathic nature, labile nature, and tendency to form aggregates, which readily precipitate clogging capillaries used for electrospray ionization (ESI). Here, we report the use of SAWN to characterize the complex glycolipid, lipid A, which serves as the membrane anchor component of lipopolysaccharide (LPS) and has a pronounced tendency to clog nano-ESI capillaries. We also show that unlike ESI SAWN is capable of ionizing labile phospholipids without fragmentation. Lastly, we compare the ease of use of SAWN to the more conventional infusion-based ESI methods and demonstrate the ability to generate higher order tandem mass spectral data of lipid A for automated structure assignment using our previously reported hierarchical tandem mass spectrometry (HiTMS) algorithm. The ease of generating SAWN-MS(n) data combined with HiTMS interpretation offers the potential for high throughput lipid A structure analysis.

  15. Ground-based intercomparison of two isoprene measurement techniques

    Directory of Open Access Journals (Sweden)

    E. Leibrock

    2003-01-01

    Full Text Available An informal intercomparison of two isoprene (C5H8 measurement techniques was carried out during Fall of 1998 at a field site located approximately 3 km west of Boulder, Colorado, USA. A new chemical ionization mass spectrometric technique (CIMS was compared to a well-established gas chromatographic technique (GC. The CIMS technique utilized benzene cation chemistry to ionize isoprene. The isoprene levels measured by the CIMS were often larger than those obtained with the GC. The results indicate that the CIMS technique suffered from an anthropogenic interference associated with air masses from the Denver, CO metropolitan area as well as an additional interference occurring in clean conditions. However, the CIMS technique is also demonstrated to be sensitive and fast. Especially after introduction of a tandem mass spectrometric technique, it is therefore a candidate for isoprene measurements in remote environments near isoprene sources.

  16. Treatment of effluent at the Saclay Centre d'Etudes Nucleaires (1960); Le traitement des effluents du Centre d'Etudes Nucleaires de Saclay (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Wormser, G [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The Centre d'Etudes Nucleaires at Saclay possesses several installations from which liquid radioactive effluent is rejected, and it has thus been found necessary to construct a station for the purification of radioactive liquids and to settle various chemical, analytical and technological problems. This report describes, in the following order: - the disposal possibilities at the Centre d'Etudes Nucleaires, Saclay, - the effluents produced at the centre, - the set-up for collecting effluent, - treatment of the effluent, - results of these treatments. (author) [French] La presence, au Centre d'Etudes Nucleaires de Saclay, de plusieurs installations susceptibles de rejeter des effluents liquides radioactifs a necessite la construction d'une station d'epuration d'eaux radioactives et la mise au point de differents problemes chimiques, analytiques et technologiques. Dans ce rapport, nous exposerons successivement: - les possibilites de rejet du Centre d'Etudes Nucleaires de Saclay, - les effluents du centre, - le dispositif de collecte des effluents, - le traitement de ces effluents, - les resultats de ces traitements. (auteur)

  17. 2DB: a Proteomics database for storage, analysis, presentation, and retrieval of information from mass spectrometric experiments.

    Science.gov (United States)

    Allmer, Jens; Kuhlgert, Sebastian; Hippler, Michael

    2008-07-07

    The amount of information stemming from proteomics experiments involving (multi dimensional) separation techniques, mass spectrometric analysis, and computational analysis is ever-increasing. Data from such an experimental workflow needs to be captured, related and analyzed. Biological experiments within this scope produce heterogenic data ranging from pictures of one or two-dimensional protein maps and spectra recorded by tandem mass spectrometry to text-based identifications made by algorithms which analyze these spectra. Additionally, peptide and corresponding protein information needs to be displayed. In order to handle the large amount of data from computational processing of mass spectrometric experiments, automatic import scripts are available and the necessity for manual input to the database has been minimized. Information is in a generic format which abstracts from specific software tools typically used in such an experimental workflow. The software is therefore capable of storing and cross analysing results from many algorithms. A novel feature and a focus of this database is to facilitate protein identification by using peptides identified from mass spectrometry and link this information directly to respective protein maps. Additionally, our application employs spectral counting for quantitative presentation of the data. All information can be linked to hot spots on images to place the results into an experimental context. A summary of identified proteins, containing all relevant information per hot spot, is automatically generated, usually upon either a change in the underlying protein models or due to newly imported identifications. The supporting information for this report can be accessed in multiple ways using the user interface provided by the application. We present a proteomics database which aims to greatly reduce evaluation time of results from mass spectrometric experiments and enhance result quality by allowing consistent data handling

  18. 2DB: a Proteomics database for storage, analysis, presentation, and retrieval of information from mass spectrometric experiments

    Directory of Open Access Journals (Sweden)

    Hippler Michael

    2008-07-01

    Full Text Available Abstract Background The amount of information stemming from proteomics experiments involving (multi dimensional separation techniques, mass spectrometric analysis, and computational analysis is ever-increasing. Data from such an experimental workflow needs to be captured, related and analyzed. Biological experiments within this scope produce heterogenic data ranging from pictures of one or two-dimensional protein maps and spectra recorded by tandem mass spectrometry to text-based identifications made by algorithms which analyze these spectra. Additionally, peptide and corresponding protein information needs to be displayed. Results In order to handle the large amount of data from computational processing of mass spectrometric experiments, automatic import scripts are available and the necessity for manual input to the database has been minimized. Information is in a generic format which abstracts from specific software tools typically used in such an experimental workflow. The software is therefore capable of storing and cross analysing results from many algorithms. A novel feature and a focus of this database is to facilitate protein identification by using peptides identified from mass spectrometry and link this information directly to respective protein maps. Additionally, our application employs spectral counting for quantitative presentation of the data. All information can be linked to hot spots on images to place the results into an experimental context. A summary of identified proteins, containing all relevant information per hot spot, is automatically generated, usually upon either a change in the underlying protein models or due to newly imported identifications. The supporting information for this report can be accessed in multiple ways using the user interface provided by the application. Conclusion We present a proteomics database which aims to greatly reduce evaluation time of results from mass spectrometric experiments and enhance

  19. Etudes sur le Portugal au Temps de l'Humanisme

    Directory of Open Access Journals (Sweden)

    J. Cruz Costa

    1953-06-01

    Full Text Available BATAILLON (Marcel. — Etudes sur le Portugal au Temps de l'Humanisme.  Acta Universitatis Conimbrigencis, 1952, 309 pp. (Primeiro Parágrafo do Artigo O Prof. Marcel Bataillon, erudito dos mais inteligentes da França atual, autor de uma obra que é hoje impr:scindível para quem pretenda estudar o humanismo renascentista na Espanha ou em Portugal, diríamos melhor, talvez: para quem pretenda estudar o Humanismo e a Renascença, — acaba de publicar, na coleção Acta Universitatis Conimbrigencis, êste volume no qual reune alguns trabalhos da mais alta importância para o conhecimento de muitos aspectos da vida espiritual portuguêsa do século XVI.

  20. A system design of gamma-ray spectrometric data processing for gold prospecting

    International Nuclear Information System (INIS)

    Yin Xueqin; Cheng Xuchu; Fang Lianxi; Huang Zuofeng.

    1992-01-01

    Based on different correlation between gamma-ray spectrometric data and gold grade in different types of gold deposits, it is necessary and possible to establish a mathematical model of gamma-ray spectrometric data processing for predicting specific gold deposits. A system design of gamma-ray spectrometric data processing for prospecting gold deposits has been worked out according to the mathematical method and procedure of data processing. The prediction effectiveness of commonly used multiple linear regression analysis is always not ideal but regression accuracy will be evidently increased after pre-processing of the calculated weight, deviation and favorability on gamma-ray spectrometric data. This system can establish more than ten models at the same time which enable users to have more choice. Tree structure and Chinese menu prompting are adopted in this system which can be utilized separately, sub-systems at different levels can be also individually operated. It can be transplanted to data processing of other similar geological deposit models (including non-gamma ray spectrometric data). The system is rapid, accurate, simple, convenient and flexible in use, more practical and easily popularized

  1. The use of car-borne gamma-ray spectrometric survey in a basin

    International Nuclear Information System (INIS)

    Liu Tengyao; Lu Shili; Luo Zongquan.

    1985-01-01

    This paper describes the geological results in a basin in the Inner Mongolia which were obtained by using our newly-developed and assembled car-borne gamma-ray spectrometric system. Combined with the work of regional geology and remote sensing, five relatively favourable uranium zones were located within the working area. The field procedures of car-borne gamma-ray spectrometry for less rigid regions is discussed. The gamma-ray spectrometric profiling is mainly used for regional reconnaissance. In the case of enhanced anomalious radioactivity the profiling with varying directions is adopted and the data are plotted on scale 1:50000 topographic map. It is suggested that the car-borne gamma-ray spectrometric system can be calibrated both by the pads specified for portable spectrometers and by testing site when the calibration facility for the car-borne gamma-ray spectrometric system is not available. The effect of rainfall on car-borne gamma-ray spectrometric survey and the simplified field qualitative determination of U-Ra disequilibrium are also briefly discussed

  2. The Combined Use of Autoradiographic and Electron Microscopic Techniques for Studies on Ultra-Thin Sections of Tritium-Labelled Cells of the Intestinal Epithelium; Emploi Combine de l'Autoradiographie et du Microscope Electronique pour L'Etude de Coupes Ultra-Fines de Cellules Tritiees de l'Epithelium Intestinal; 0421 043e 0432 043c 0435 0414 ; Empleo Combinado de Tecnicas de Autorradiografia y de MicroscopiA Electronica para Estudiar Cortes Ultrafinos de Celulas Tritiadas del Epitelio Intestinal

    Energy Technology Data Exchange (ETDEWEB)

    Hampton, J. C. [Division of Experimental Biology, Baylor University College of Medicine, TX (United States); Quastler, H. [Brookhaven National Laboratory, Upton, Long Island, NY (United States)

    1962-02-15

    The high resolution now obtainable in sectioned cells studied in the electron microscope offers some promise of visualizing some of the intracellular events leading to the synthesis of proteins. The specificity of incorporation of tritiated thymidine into DNA provides a system which can be accurately followed with respect to time and localization within the cell. The work to be reported here demonstrates that it is possible to study ultra-thin sections of labelled cells in the electron microscope, to remove the specimen after suitable electron micrographs have been taken, to apply a coating of emulsion sufficiently thick to obtain an autoradiograph but still thin enough' to permit re-examination of the specimen in the electron microscope and to obtain electron micrographic images of autoradiography of cells previously recorded. The autoradiographic emulsion was applied as follows: a thin film was formed by dipping a small wire loop into liquid emulsion and transferring the film by passing the loop over the mounted specimen which was fixed to the top of a small plastic peg. Adequate control can be achieved by taking a one-half micron section after each ultra-thin section during sectioning, mounting it on a glass slide and applying conventional autoradiographic techniques. Because of the fragile nature of ultra-thin sections, the yield of successful autoradiographs is quite low. In spite of this objection it is expected that with improvements in skill and techniques the method will facilitate a better understanding of vital cell processes. (author) [French] Le haut degre de resolution que l'on peut maintenant obtenir dans l'etude des coupes de cellules au microscope electronique offre quelque possiblite d'observer certains des processus intracellulaires qui menent a la synthese des proteines. Le fait que la thymidine tritiee s'incorpore a l'ADN de facon specifique permet de suivre avec precision le deroulement d'un autre processus dans le temps et leur localisation

  3. The ultrasonic copper and brass decontamination study; Etude de la decontamination du cuivre et des laitons en presence d'ultra-sons

    Energy Technology Data Exchange (ETDEWEB)

    Courtault, J; Kerdelleau, J de; Mestre, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    The use of ultra-sounds as a decontamination technic does not bring an absolute solution. As a function of the materials it seemed necessary to find what was the optimum conditions for using the ultra-sounds and to define not only the ultra-sonic factors but also the chemical solutions which bring some appreciable decontamination factors without bringing any too important corrosion processus. This report gives the results of this study applied to copper and brass. This study allowed to select some effective treatment baths on the two types of contamination: plutonium and fission products. (authors) [French] L'emploi des ultra-sons comme technique de decontamination n'amene pas une solution absolue. Il est apparu necessaire de rechercher en fonction de la nature du materiau a decontaminer quelles etaient les conditions optimales d'utilisation des ultra-sons et de definir alors non seulement les facteurs ultrasoniques mais encore les solutions chimiques qui apportent des facteurs de decontamination appreciables sans amener des phenomenes de corrosion trop importants. Ce rapport donne les resultats de cette etude appliquee au cuivre et aux laitons. Cette etude a permis de selectionner des bains de traitement efficaces dans les deux cas de contamination: plutonium et produits de fission. (auteurs)

  4. Atomic absorption spectrometric determination of mineral elements in mammalian bones

    International Nuclear Information System (INIS)

    Udoh, Anthony P.

    2000-01-01

    The phosphorus content of the major bones of male and female selected mammals was determined using the yellow vanadomolybdate colorimetric method. For each animal, the bone with the highest phosphorus content was used as pilot sample. Varying concentrations of strontium were added to solutions of the ashed pilot samples to minimize phosphorus interference in the determination of calcium and magnesium using flame atomic absorption spectrophotometry operated on the air-acetylene mode. At least 6,000 ppm (0.6%) of strontium was required to give optimum results for calcium. The amount of magnesium obtained from the analysis was not affected by the addition of strontium. With the incorporation of strontium in the sample solution, all elements of interest can be determined in the same sample solution. Based on this, a procedure is proposed for the determination of calcium and other elements in bones. Average recoveries of spiked calcium and magnesium were 97.85% and 98.16%, respectively at the 95% confidence level. The coefficients of variation obtained for replicate determinations using one of the samples were 0.00% for calcium, lead and sodium, 2.93% for magnesium, 3.27% for iron and 3.92% for zinc at the concentration levels found in that sample. Results from the proposed procedure compared well with those from classical chemical methods at the 95% confidence level. It is evident that calcium phosphorus, magnesium and sodium which are the most abundant elements in the bones are distributed in varying amounts both in the different types of bones and different animal species, although the general trend is Ca > P > Na > Mg for each bone considered. The calcium - phosphorus ratio is generally 3:1. The work set out to propose an atomic absorption spectrometric method for the multi-element analysis of mammalian bones with a single sample preparation and to study the distribution pattern of these elements in the bones. (Author)

  5. Experimental characterization of the Clear-PEM scanner spectrometric performance

    Energy Technology Data Exchange (ETDEWEB)

    Bugalho, R; Carrico, B; Ferreira, C S; Frade, M; Ferreira, M; Moura, R; Ortigao, C; Pinheiro, J F; Rodrigues, P; Rolo, I; Silva, J C; Trindade, A; Varela, J [Laboratorio de Instrumentacao e Fisica Experimental de Particulas (LIP), Av. Elias Garcia 14-1, 1000-149 Lisboa (Portugal)], E-mail: frade@lip.pt

    2009-10-15

    In the framework of the Clear-PEM project for the construction of a high-resolution and high-specificity scanner for breast cancer imaging, a Positron Emission Mammography tomograph has been developed and installed at the Instituto Portugues de Oncologia do Porto hospital. The Clear-PEM scanner is mainly composed by two planar detector heads attached to a robotic arm, trigger/data acquisition electronics system and computing servers. The detector heads hold crystal matrices built from 2 x 2 x 20 mm{sup 3} LYSO:Ce crystals readout by Hamamatsu S8550 APD arrays. The APDs are optically coupled to both ends of the 6144 crystals in order to extract the DOI information for each detected event. Each one of 12288 APD's pixels is read and controlled by Application Specific Integrated Circuits water-cooled by an external cooling unit. The Clear-PEM frontend boards innovative design results in a unprecedented integration of the crystal matrices, APDs and ASICs, making Clear-PEM the PET scanner with the highest number of APD pixels ever integrated so far. In this paper, the scanner's main technical characteristics, calibration strategies and the first spectrometric performance evaluation in a clinical environment are presented. The first commissioning results show 99.7% active channels, which, after calibration, have inter-pixel and absolute gain distributions with dispersions of, respectively, 12.2% and 15.3%, demonstrating that despite the large number of channels, the system is uniform. The mean energy resolution at 511 keV is of 15.9%, with a 8.8% dispersion, and the mean C{sub DOI}{sup -1} is 5.9%/mm, with a 7.8% dispersion. The coincidence time resolution, at 511 keV, for a energy window between 400 and 600 keV, is 5.2 ns FWHM.

  6. Data processing in gamma spectrometry. Application to the decay schemes study; Traitement des informations en spectrometrie gamma application a l'etude de schemas de desintegration

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires, departement d' electronique generale, service d' instrumentation nucleaire

    1968-06-01

    The purpose of this thesis is the processing of the data issued from a gamma spectrometer, and its applications to the decay schemes study. The mathematical analysis of the full energy peaks, in connection with the very good resolution of semi-conductor detectors, leads to a very accurate determination of the energies. The resolution of complex spectra by the least squares method, completed by a spectra generating process, allows the calculation of branching ratios. Then, the handling of the two dimensional experiments permits the coincidence exam. For each of these methods, the calculation principle, then the systematics tests realized in order to prove their validity and to determine their application ranges as well as some experimental results appropriate to illustrate their possibilities, are presented. The energies of some nuclides, frequently used as standards have been thus measured and the decay schemes of {sup 134}Cs and {sup 110m}Ag determined precisely. (author) [French] Cette these est consacree aux methodes de traitement des informations issues d'un spectrometre {gamma}, et a leur application a l'etude des schemas de desintegration: l'analyse mathematique des pics d'absorption totale, conjuguee avec l'excellent pouvoir de resolution des detecteurs semi-conducteurs, conduit a une determination tres precise des energies. La decomposition des spectres complexes par la methode des moindres carres, completee par un procede de generation de spectres, autorise le calcul des rapports de branchement. Enfin le depouillement des experiences biparametriques permet l'examen des coincidences. Pour chacune de ces methodes, on expose le principe des calculs et les essais systematiques effectues afin d'eprouver leur validite et de definir leurs domaines d'application, ainsi que quelques resultats experimentaux propres a illustrer leurs possibilites. Les energies de quelques isotopes utilises couramment comme etalons ont ainsi ete mesurees, et les schemas de

  7. Spectrometric and Voltammetric Analysis of Urease – Nickel Nanoelectrode as an Electrochemical Sensor

    Directory of Open Access Journals (Sweden)

    Rene Kizek

    2007-07-01

    Full Text Available Urease is the enzyme catalyzing the hydrolysis of urea into carbon dioxide andammonia. This enzyme is substrate-specific, which means that the enzyme catalyzes thehydrolysis of urea only. This feature is a basic diagnostic criterion used in thedetermination of many bacteria species. Most of the methods utilized for detection ofurease are based on analysis of its enzyme activity – the hydrolysis of urea. The aim of thiswork was to detect urease indirectly by spectrometric method and directly by voltammetricmethods. As spectrometric method we used is called indophenol assay. The sensitivity ofdetection itself is not sufficient to analyse the samples without pre-concentration steps.Therefore we utilized adsorptive transfer stripping technique coupled with differential pulse voltammetry to detect urease. The influence of accumulation time, pH of supporting electrolyte and concentration of urease on the enzyme peak height was investigated. Under the optimized experimental conditions (0.2 M acetate buffer pH 4.6 and accumulation time of 120 s the detection limit of urease evaluated as 3 S/N was 200 ng/ml. The activity of urease enzyme depends on the presence of nickel. Thus the influence of nickel(II ions on electrochemical response of the enzyme was studied. Based on the results obtained the interaction of nickel(II ions and urease can be determined using electrochemical methods. Therefore we prepared Ni nanoelectrodes to measure urease. The Ni nanoelectrodes was analysed after the template dissolution by scanning electron microscopy. The results shown vertically aligned Ni nanopillars almost covered the electrode surface, whereas the defect places are minor and insignificant in comparison with total electrode surface. We were able to not only detect urease itself but also to distinguish its native and denatured form.

  8. Spectrometric methods for the determination of chlorine in crude oil and petroleum derivatives — A review

    International Nuclear Information System (INIS)

    Doyle, Adriana; Saavedra, Alvaro; Tristão, Maria Luiza B.; Mendes, Luiz A.N.; Aucélio, Ricardo Q.

    2013-01-01

    Chlorine determination in crude oil is made in order to guarantee that the oil does not contain levels of this element that might cause damages in the oil processing equipment. In petroleum products, the determination of chlorine is made, for instance, to evaluate if there are proper concentrations of organochloride compounds, which are used as additives. Such determinations are currently performed following official guidelines from the ASTM International and from the United States Environmental Protection Agency as well as protocols indicated by the Universal Oil Products. X-ray fluorescence spectroscopy plays an important role in many of these official methods. In contrast, other spectrometric methods based on optical and mass detection are plagued by limitations related to both the fundamental characteristics of non-metals and to the complex sample matrices, which reflects in the small number of articles devoted to these applications. In this review, the current status of the spectrometric methods, especially the role played by X-ray fluorescence spectrometry, is evaluated in terms of the determination of chlorine in crude oil and petroleum derivatives. Comparison of the performance of the methods, limitations and potential new approaches to ensure proper spectrometric determinations of chlorine is indicated. - Highlights: • Critical evaluation of spectrometric methods for chlorine in petroleum products. • Reviews on element determination in petroleum have not address the case of chlorine. • Peculiarities of the spectrometric determination of Cl in petroleum are discussed. • The spectrometric approaches are detailed and compared to the official methods. • New trends in chlorine determination in petroleum products are indicated

  9. Analysis of Low-Pressure Gas-Phase Pyrolytic Reactions by Mass Spectrometric Techniques,

    Science.gov (United States)

    1989-01-01

    with distilled water the assembled filaments were gold plated by electrolysis, the filaments being the anode and pure metallic gold the cathode. The...electrolysis bath contained 8 g of KCN, 4 gof NaPO, 4g of NaGH and 2 gof AuCI 3 per litre. The electrolyses were carried out at 60’C with efficient...stirring, the current being 5-10 mA. Following the electroplating the assembled filaments were thoroughly cleaned with distilled water , separated and

  10. Comparison of extraction techniques and mass spectrometric ionization modes in the analysis of wine volatile carbonyls

    Energy Technology Data Exchange (ETDEWEB)

    Zapata, Julian; Mateo-Vivaracho, Laura; Cacho, Juan [Laboratory for Flavor Analysis and Enology, Institute of Engineering of Aragon, I3A, Department of Analytical Chemistry, Faculty of Sciences, University of Zaragoza, 50009 Zaragoza (Spain); Ferreira, Vicente, E-mail: vferre@unizar.es [Laboratory for Flavor Analysis and Enology, Institute of Engineering of Aragon, I3A, Department of Analytical Chemistry, Faculty of Sciences, University of Zaragoza, 50009 Zaragoza (Spain)

    2010-02-15

    This work presents a comparative study of the analytical characteristics of two methods for the analysis of carbonyl compounds in wine, both based on the derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA). In the first method derivatives are formed in the solid phase extraction (SPE) cartridge in which the analytes have been previously isolated, while in the second method derivatives are formed in a solid phase microextraction (SPME) fibre saturated with vapors of the reagent and exposed to the sample headspace. In both cases detection has been carried out by electron impact (EI) or negative chemical ionization (NCI) mass spectrometry. The possibility of determining haloanisols simultaneously has been also considered. The method based on SPE presents, in general, better analytical properties than the SPME one. Although linearity was satisfactory for both methods (R{sup 2} > 0.99), repeatability of the SPE method (RSD < 10%) was better than that obtained with SPME (9% < RSD < 20%). Detection limits obtained with EI are better for the SPE method except for trihaloanisols, while with NCI detection limits for both strategies are comparable, although the SPME strategy presents worse results for ketones and methional. Detection limits are always lower with NCI, being the improvement most notable for SPME. Recovery experiments show that in the case of SPE, uncertainties are lower than 12% in all cases, while with the SPME method the imprecision plus the existence of matrix effects make the global uncertainty to be higher than 15%.

  11. Comparison of extraction techniques and mass spectrometric ionization modes in the analysis of wine volatile carbonyls

    International Nuclear Information System (INIS)

    Zapata, Julian; Mateo-Vivaracho, Laura; Cacho, Juan; Ferreira, Vicente

    2010-01-01

    This work presents a comparative study of the analytical characteristics of two methods for the analysis of carbonyl compounds in wine, both based on the derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA). In the first method derivatives are formed in the solid phase extraction (SPE) cartridge in which the analytes have been previously isolated, while in the second method derivatives are formed in a solid phase microextraction (SPME) fibre saturated with vapors of the reagent and exposed to the sample headspace. In both cases detection has been carried out by electron impact (EI) or negative chemical ionization (NCI) mass spectrometry. The possibility of determining haloanisols simultaneously has been also considered. The method based on SPE presents, in general, better analytical properties than the SPME one. Although linearity was satisfactory for both methods (R 2 > 0.99), repeatability of the SPE method (RSD < 10%) was better than that obtained with SPME (9% < RSD < 20%). Detection limits obtained with EI are better for the SPE method except for trihaloanisols, while with NCI detection limits for both strategies are comparable, although the SPME strategy presents worse results for ketones and methional. Detection limits are always lower with NCI, being the improvement most notable for SPME. Recovery experiments show that in the case of SPE, uncertainties are lower than 12% in all cases, while with the SPME method the imprecision plus the existence of matrix effects make the global uncertainty to be higher than 15%.

  12. Reference Materials for Trace Element Microanalysis of Carbonates by SIMS and other Mass Spectrometric Techniques

    Science.gov (United States)

    Layne, G. D.

    2009-12-01

    Today, many areas of geochemical research utilize microanalytical determinations of trace elements in carbonate minerals. In particular, there has been an explosion in the application of Secondary Ion Mass Spectrometry (SIMS) to studies of marine biomineralization. SIMS provides highly precise determinations of Mg and Sr at the concentration levels normally encountered in corals, mollusks or fish otoliths. It is also a highly effective means for determining a wide range of other trace elements at ppm levels (e.g., Na, Fe, Mn, Ba, REE, Pb, Th, and U) in a variety of naturally occurring calcite and aragonite matrices - and so is potentially valuable in studies of diagenesis, hydrothermal fluids and carbonatitic magmas. For SIMS, modest time per spot (often sputtered ion yields of most elements with the major element composition of the sample matrix, accuracy of SIMS depends intimately on matrix-matched solid reference materials. Despite its rapidly increasing use for trace element analyses of carbonates, there remains a dearth of certified reference materials suitable for calibrating SIMS. The pressed powders used by some analysts to calibrate LA-ICP-MS do not perform well for SIMS - they are not perfectly dense or homogeneous to the desired level at the micron scale of sampling. Further, they often prove incompatible with the sample high vacuum compatibility requirement for stable SIMS analysis (10-8 to 10-9 torr). Some naturally occurring calcite has apparent utility as a reference material. For example, equigranular calcite from some zones of carbonatite intrusions (sovites) and recrystallized calcites from highly metamorphosed metallic ore deposits. Most calcite marbles, though possibly appropriate as Sr standards, show substantial inhomogeneity in Mg, Mn and Ba. Some hydrothermal “Iceland Spar” calcite may prove useful as a reference for extremely low concentrations of Mg, Sr and Ba. The best carbonatitic calcites currently in use appear homogeneous to better than 2-3% for Sr (and somewhat less homogeneous for Mg). But these standards still require numerous replicate analyses during analytical sessions to reduce the overall uncertainty to <<1.0%.The availability of appropriate certified solid reference materials with a high degree of homogeneity would greatly benefit the utilization and inter-comparison of SIMS determinations in carbonates, while substantially reducing the time consumed in calibration. Some studies would also benefit from the extension of this effort to the characterization of appropriate standards of other rhombohedral carbonates (especially dolomite and Fe-rich calcite).

  13. The application of mercury-containing labels in protein analysis using complementary mass spectrometric techniques

    OpenAIRE

    Kutscher, Daniel Jurgen

    2014-01-01

    En la presente tesis doctoral se desarrollaron nuevas metodologías para el análisis cuantitativo de proteínas basadas en la introducción química de un compuesto de mercurio capaz de unirse a las cisteínas libres de estas biomoléculas. El ácido hidroximercuribenzoico tiene un alto potencial como agente derivatizante, ya que es capaz de actuar de forma selectiva y completa sobre los residuos de cisteína presentes en las proteínas. El objetivo fundamental del proyecto ha sido la utilización d...

  14. Determination of nuclear fuel burn-up using mass spectrometric techniques

    International Nuclear Information System (INIS)

    Saha, B.; Bagyalakshmi, R.; Periaswami, G.; Kavimandan, V.D.; Chitambar, S.A.; Jain, H.C.; Mathews, C.K.

    1977-01-01

    Determination of burn-up using a stable fission product monitor such as 148 Nd and heavy elements, determined by isotope dilution mass spectrometry gives the most accurate data. This report describes the work carried out to standardise the conditions for burn-up determination. Some typical results are given. (author)

  15. Study of radionuclides speciation with biological molecules of interest by spectrometric techniques

    International Nuclear Information System (INIS)

    Lourenco, V.

    2007-07-01

    Mechanisms of complexation and accumulation of the radionuclides at the cellular and molecular level are complex and poorly known because the studies on these subjects are scarce. Within the framework of this thesis, we studied the interactions of europium (analogue of trivalent actinides) and uranium (VI) (actinide) with biological molecules of interest: phyto-chelatins. Their role is to protect cells against intrusions from nonessential heavy metals (thus toxic). These proteins are likely to be implied in the mechanisms of sequestration of radionuclides in living organisms. However, their structure is complex, this is why, in order to better understand their reactivity, we extended our studies to lower entities which constitute them (amino acids and glutathione). We determined solution speciation (stoichiometry, structure) as well as the complexing constants associated with the formation of these species. These studies were undertaken by Time Resolved Laser induced Fluorescence (TRLIF), Electro-Spray Mass Spectrometry (ES-MS), Nuclear Magnetic Resonance (NMR), Fourier Transform Infra-Rouge spectroscopy (FTIR) and Extended X-ray Absorption Fine Structure Spectroscopy (EXAFS). The determination of the complexation constants enabled us to conclude that the complexing capacity of these molecules with respect to radionuclides was moderate (log 10 K 1 < 3, pH 3 or 6), the formed species are mononuclear with only one ligand molecule (1:1). The interaction is performed via oxygenated (hard) groups. The direct complexation of europium with phyto-chelatins at acidic pH was studied jointly by TRLIF and ES-MS. The complexing capacity of these molecules is much higher than that of GSH from which they result. In addition to studies undertaken on synthetic solutions reproducing the 'biological' conditions (pH close to neutrality, ionic strength 0.1 mol/L, etc), tests of cellular contamination were realized. The quantification of integrated europium showed that those are able to incorporate europium significantly. (author)

  16. Study of radionuclides speciation with biological molecules of interest by spectrometric techniques

    International Nuclear Information System (INIS)

    Lourenco, V.

    2007-07-01

    Mechanisms of complexation and accumulation of the radionuclides at the cellular and molecular level are complex and poorly known because the studies on these subjects are scarce. Within the framework of this thesis, we studied the interactions of these cations with biological molecules of interest. We chose to focus on an actinide: uranium (VI) as well as europium as an analogue of trivalent actinides. The selected biological molecules are the phyto-chelatins: their role is to protect cells against intrusions from nonessential heavy metals (thus toxic). These proteins are likely to be implied in the mechanisms of sequestration of radionuclides in living organisms. However, their structure is complex, this is why, in order to better include/understand their reactivity, we extended our studies to lower entities which constitute them (amino acid: glycine, glutamic acid and cysteine; polypeptides: glutathione reduced and oxidized forms). In particular, we determined solution speciation (stoichiometry, structure) as well as the complexing constants associated with the formation with these species. These studies were undertaken by Time Resolved Laser induced Fluorescence (TRLIF), Electro-Spray-Mass Spectrometry (ES-MS), Nuclear Magnetic Resonance (NMR), Fourier Transform Infra-Rouge spectroscopy (FTIR) and Extended X-ray Absorption Fine Structure Spectroscopy (EXAFS).The determination of the complexation constants enabled us to conclude that the complexing capacity of these molecules with respect to radionuclides was moderate (log 10 K 1 ≤ 3, pH 3 or 6), the formed species are mononuclear with only one ligand molecule (1:1). The interaction is performed via oxygenated (hard) groups. The direct complexation of europium with phyto-chelatins at acidic pH was studied jointly by TRLIF and ES-MS. The complexing capacity of these molecules is much higher than that of GSH from which they result. The interaction of europium with metallothioneins is, on the contrary, lower than with phyto-chelatins. In addition to studies undertaken on synthetic solutions reproducing the 'biological' conditions (pH close to neutrality, ionic strength 0,1 mol/L, etc), tests of cellular contamination were realized. We let cells grow in culture media comprising various europium concentrations. The quantification of integrated europium (by million cells) showed that those are able to incorporate europium significantly. (author)

  17. Application of mass spectrometric techniques to delineate the modes-of-action of anticancer metallodrugs

    NARCIS (Netherlands)

    Hartinger, Christian G.; Groessl, Michael; Meier, Samuel M.; Casini, Angela; Dyson, Paul J.

    2013-01-01

    Mass spectrometry (MS) has emerged as an important tool for studying anticancer metallodrugs in complex biological samples and for characterising their interactions with biomolecules and potential targets on a molecular level. The exact modes-of-action of these coordination compounds and especially

  18. A general X-ray fluorescence spectrometric technique based on simple corrections for matrix effects

    International Nuclear Information System (INIS)

    Kruidhof, H.

    1978-01-01

    The method reported, which is relatively simple and generally applicable for most materials, involves a combination of borax fusion with matrix effect corrections. The latter are done with algorithms, which are derived from the intensity formulae, together with empirical coefficients. (Auth.)

  19. Rocket-borne measurements of atmospheric infrared emissions by spectrometric techniques

    Science.gov (United States)

    Brueckelmann, H. G.; Grossmann, K. U.; Offermann, D.

    As part of the MAP/WINE Campaign 1983/84 a liquid-He-cooled IR grating spectrometer measured night zenith radiances of CO2, O3, and H2O in the mesosphere and lower thermosphere. From a comparison of the measured spectral radiances with results from LTE radiative-transfer calculations, atmospheric temperatures and concentration profiles of H2O and O3 were determined, showing some interesting features. The O3 densities appear to contradict model predictions based upon the assumption that O3 is in photochemical equilibrium at mesospheric heights. Since the O3 density distribution shows structures quite similar to the vertical wind profile, transport effects seem to play a major role in the mesospheric O3 formation.

  20. Determination of rhenium in molybdenite by X-ray fluorescence: A combined chemical-spectrometric technique.

    Science.gov (United States)

    Solt, M W; Wahlberg, J S; Myers, A T

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 microg of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods.

  1. Determination of rhenium in molybdenite by X-ray fluorescence. A combined chemical-spectrometric technique

    Science.gov (United States)

    Solt, M.W.; Wahlberg, J.S.; Myers, A.T.

    1969-01-01

    Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 ??g of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods. ?? 1969.

  2. Spectrometric techniques application to study of environmental contamination levels in south Shetland Antarctic

    International Nuclear Information System (INIS)

    Vera Tartaglia, C.; Camarota, R.; Costa, V.

    1993-01-01

    The methodology for studying the behaviour of the toxic pollutant metals (Hg, Pb, Cd, Cr) in the South Shetland region is presented here, toxic pollutants are caused by the urban and industrial activity at the Southern hemisphere and they are pressured to be incorporated to the region though atmospheric transport processes the Cs 137 (refI) was used as a tracing element, which was freed and dispersed in the atmosphere as a result of nuclear bombs testing. During the austral summer samples from ground, sediments, atmospheric and glacier were extracted.

  3. Stability and linearity control of spectrometric channels of the Cherenkov counters using controllable units

    International Nuclear Information System (INIS)

    Kollar, D.; Kollarova, L.; Khorvat, P.

    1976-01-01

    A system is elaborated to control stability and linearity of the Cherenkov counter spectrometric channels in an experiment on a magnetic monopole search. Linearity of a light characteristic of a photoelectric multiplier is checked with the help of the calibrated light-strikings of light emitting diodes with flare intensity adjusted by controlling generator voltage across the mercury body. A program algorithm is presented for checking stability and linearity of the Cherenkov counter spectrometric channels which helps to consider the fatigue effects of the photoelectric multiplier resulting from the considerable loads

  4. Mass Spectrometric Characteristics of Prenylated Indole Derivatives from Marine-Derived Penicillium sp. NH-SL.

    Science.gov (United States)

    Ding, Hui; Ding, Wanjing; Ma, Zhongjun

    2017-03-22

    Two prenylated indole alkaloids were isolated from the ethyl acetate extracts of a marine-derived fungus Penicillium sp. NH-SL and one of them exhibited potent cytotoxic activity against mouse hepa 1c1c7 cells. In order to detect other bioactive analogs, we used liquid chromatogram tandem mass spectrometry (LC-MS/MS) to analyze the mass spectrometric characteristics of the isolated compounds as well as the crude extracts. As a result, three other analogs were detected, and their structures were deduced according to the similar fragmentation patterns. This is the first systematic report on the mass spectrometric characteristics of prenylated indole derivatives.

  5. Spectrometric properties of crystals for low-energy x-ray diagnostics

    International Nuclear Information System (INIS)

    Barrus, D.m.; Blake, R.L.; Felthauser, H.; Fenimore, E.E.

    1981-01-01

    Quantitative diagnostics of fusion and astrophysical plasmas require knowledge of crystal spectrometric properties. To provide more reliable and versatile diagnostics of plasma conditions, increasingly accurate knowledge of crystal spectrometric properties is becoming necessary. A summary is presented of the following accurately measured parameters for the crystals KAP, RbAP, TlAP, NH 4 AP, NaAP, ADP, and EDDT: the interplanar spacing of atoms; the angle correction for normal and anomalous dispersion that is required for application of the Bragg formula; the thermal expansion coefficient near room temperature for commonly used planes; and the integrated coefficient of reflection

  6. iMS2Flux – a high–throughput processing tool for stable isotope labeled mass spectrometric data used for metabolic flux analysis

    Directory of Open Access Journals (Sweden)

    Poskar C Hart

    2012-11-01

    Full Text Available Abstract Background Metabolic flux analysis has become an established method in systems biology and functional genomics. The most common approach for determining intracellular metabolic fluxes is to utilize mass spectrometry in combination with stable isotope labeling experiments. However, before the mass spectrometric data can be used it has to be corrected for biases caused by naturally occurring stable isotopes, by the analytical technique(s employed, or by the biological sample itself. Finally the MS data and the labeling information it contains have to be assembled into a data format usable by flux analysis software (of which several dedicated packages exist. Currently the processing of mass spectrometric data is time-consuming and error-prone requiring peak by peak cut-and-paste analysis and manual curation. In order to facilitate high-throughput metabolic flux analysis, the automation of multiple steps in the analytical workflow is necessary. Results Here we describe iMS2Flux, software developed to automate, standardize and connect the data flow between mass spectrometric measurements and flux analysis programs. This tool streamlines the transfer of data from extraction via correction tools to 13C-Flux software by processing MS data from stable isotope labeling experiments. It allows the correction of large and heterogeneous MS datasets for the presence of naturally occurring stable isotopes, initial biomass and several mass spectrometry effects. Before and after data correction, several checks can be performed to ensure accurate data. The corrected data may be returned in a variety of formats including those used by metabolic flux analysis software such as 13CFLUX, OpenFLUX and 13CFLUX2. Conclusion iMS2Flux is a versatile, easy to use tool for the automated processing of mass spectrometric data containing isotope labeling information. It represents the core framework for a standardized workflow and data processing. Due to its flexibility

  7. Contribution to the study of several chemical hazards in the Centre d'Etudes Nucleaires of Fontenay-aux-Roses; Contribution a l'etude de quelques nuisances chimiques au centre d'etudes nucleaires de Fontenay-aux-Roses

    Energy Technology Data Exchange (ETDEWEB)

    Megemont, C; Grau, C [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-10-01

    From the checking of 2750 index cards of hazards, the study relates the distribution of the chemical hazards in the Centre d'Etudes Nucleaires of Fontenay-aux-Roses. Those concerning the greatest number of agents in the Centre are classified according to the categories corresponding to the different conditions of working. Thus, the most important are put forward. Then, the authors rapidly make a review of hazards which may have some special interest because they appear more specific of the nuclear energy or because they are the most frequently noted on the index cards of hazards. The case of the tributylphosphate is studied more precisely. (authors) [French] A partir de l'examen de 2750 fiches de nuisances, l'etude porte sur la repartition des nuisances chimiques au Centre d'Etudes Nucleaires de Fontenay-aux-Roses. Celles qui concernent le plus grand nombre d'agents du Centre sont classees selon les categories correspondant aux differentes conditions de travail. Les plus importantes d'entre elles sont ainsi mises en evidence. | Les auteurs passent ensuite en revue, rapidement, les nuisances qui peuvent presenter un interet particulier soit parce qu'elles semblent plus specifiques de l'Energie Nucleaire, soit parce qu'on les rencontre le plus frequemment sur les fiches de nuisances. Le cas du tributylphosphate est envisage de facon plus detaillee. (auteurs)

  8. Gamma-spectrometric analysis of river sediments collected around phosphate fertilizer industries

    International Nuclear Information System (INIS)

    Gallardo, M.C.; Garcia-Leon, M.; Mundi, M.; Respaldiza, M.A.

    1993-01-01

    Gamma-ray spectrometric analysis has been carried out on sediments collected in an estuarine system formed by two major rivers in southern Spain. The results show clearly that important amounts of natural radioactivity are accumulating on the bed of both rivers. This radioactivity appears to originate from effluent from several phoshate fertilizer factories adjacent to the estuary. (author)

  9. Spectrometric storage device in VME standard; Spektrometricheskoe zapominayushchee ustrojstvo v standarte VME

    Energy Technology Data Exchange (ETDEWEB)

    Rezaev, V E

    1996-12-31

    Paper describes module of histogram Memory Module designed to implement hardware way of accumulation of spectrometric data in systems based on VME standard equipment. Application of HMM module enables to increase throughput of the system for data acquisition and processing as in this case VME bus trunk is not occupied and may be used to control experiment course. 2 figs.

  10. On the Origin of Microheterogeneity : A Mass Spectrometric Study of Dimethyl Sulfoxide-Water Binary Mixture

    NARCIS (Netherlands)

    Shin, Dong Nam; Wijnen, Jan W.; Engberts, Jan B.F.N.; Wakisaka, Akihiro

    2001-01-01

    We have studied the microscopic solvent structure of dimethyl sulfoxide-water mixtures and its influence on the solvation structure of solute from a clustering point of View, by means of a specially designed mass spectrometric system. It was observed that the propensity to the cluster formation is

  11. Retrospective detection of exposure to organophosphorus anti-cholinesterases: Mass spectrometric analysis of phosphylated human butyrylcholinesterase

    NARCIS (Netherlands)

    Fidder, A.; Hulst, A.G.; Noort, D.; Ruiter, R. de; Schans, M.J. van der; Benschop, H.P.; Langenberg, J.P.

    2002-01-01

    In this paper a novel and general procedure is presented for detection of organophosphate-inhibited human butyrylcholinesterase (HuBuChE), which is based on electrospray tandem mass spectrometric analysis of phosphylated nonapeptides obtained after pepsin digestion of the enzyme. The utility of this

  12. Radiochemical separation and alpha-spectrometric determination of Americium in different matrixes

    International Nuclear Information System (INIS)

    Radenkovic, M.; Joksic, J.; Paligoric, D.

    2009-01-01

    A method of separation and alpha-spectrometric determination of americium, developed in VINCA Institute of Nuclear Sciences is described in the paper. The procedure is convenient to be used for 241 Am determination in environmental matrixes as well as samples of human origin if a very small concentrations are expected, using 243 Am as a tracer for radiochemical yield recovery. (author) [sr

  13. Structure elucidation of metabolite x17299 by interpretation of mass spectrometric data.

    Science.gov (United States)

    Zhang, Qibo; Ford, Lisa A; Evans, Anne M; Toal, Douglas R

    2017-01-01

    A major bottleneck in metabolomic studies is metabolite identification from accurate mass spectrometric data. Metabolite x17299 was identified in plasma as an unknown in a metabolomic study using a compound-centric approach where the associated ion features of the compound were used to determine the true molecular mass. The aim of this work is to elucidate the chemical structure of x17299, a new compound by de novo interpretation of mass spectrometric data. An Orbitrap Elite mass spectrometer was used for acquisition of mass spectra up to MS 4 at high resolution. Synthetic standards of N,N,N -trimethyl-l-alanyl-l-proline betaine (l,l-TMAP), a diastereomer, and an enantiomer were chemically prepared. The planar structure of x17299 was successfully proposed by de novo mechanistic interpretation of mass spectrometric data without any laborious purification and nuclear magnetic resonance spectroscopic analysis. The proposed structure was verified by deuterium exchanged mass spectrometric analysis and confirmed by comparison to a synthetic standard. Relative configuration of x17299 was determined by direct chromatographic comparison to a pair of synthetic diastereomers. Absolute configuration was assigned after derivatization of x17299 with a chiral auxiliary group followed by its chromatographic comparison to a pair of synthetic standards. The chemical structure of metabolite x17299 was determined to be l,l-TMAP.

  14. The AS-76 interlaboratory experiment on the alpha spectrometric determination of Pu-238. Pt. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Spannagel, G.

    1979-12-01

    In cooperation with 26 laboratories of 11 countries or international organizations, the Safeguards Project of the Karlsruhe Nuclear Research Center carried out the interlaboratory program AS-76. It focused on the alpha-spectrometric determination of the Pu-238 isotope. The performance of the program as well as the results obtained are described. (orig.) 891 HP/orig. 892 MKO [de

  15. Mass spectrometric identification of isocyanate-induced modifications of keratins in human skin

    NARCIS (Netherlands)

    Hulst, A.G.; Verstappen, D.R.W.; Riet-van Oeveren, D. van der; Vermeulen, N.P.E.; Noort, D.

    2015-01-01

    In the current paper we show that exposure of human callus to isocyanates leads to covalent modifications within keratin proteins. Mass spectrometric analyses of pronase digests of keratin isolated from exposed callus show that both mono- and di-adducts (for di-isocyanates) are predominantly formed

  16. Electron multiplier for the measurement of an ion current on a mass spectrometer; Multiplicateur d'electrons pour la mesure de courant d'ions sur un spectrometre de masse

    Energy Technology Data Exchange (ETDEWEB)

    Lohez, P; Nief, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The apparatus described is designed to measure weak ion currents received at the collector of a mass spectrometer. The report describes successively the study of electron paths in the multiplier by the method of analogy, using rubber membranes, and the practical details of construction of the apparatus. The variation with surface treatment of the secondary emission coefficient of the alloy CuBe containing 2 per cent Be, which makes up the dynodes, and the influence of the voltage on the gain per stage, are discussed. Results of tests regarding: the influence of the ion mass on the gain, the background of the instrument and the energy distribution of the impulses coming out on a high gain multiplier (q.q. 10{sup 7}) are given. Finally the performances of the multiplier are reported. 1- For a low gain (10{sup 4}), precision and reproducibility comparable to the electrometer valve, sensitivity 100 times greater, currents capable of detection 10{sup -17} Ampere. 2- For a high gain (10{sup 7}) and measurement by impulse counting, currents capable of detection 10{sup -19} Ampere. Mounting difficult to use on a mass spectrometer. (author) [French] L'appareil decrit est destine a la mesure des faibles courants d'ions re s au collecteur d'un spectrometre de masse. Le rapport decrit successivement l'etude des trajectoires des electrons dans le multiplicateur, par la methode analogique de la menbrane en caoutchouc, et la realisation pratique de l'appareil. La variation du coefficient d'emission secondaire de l'alliage CuBe a 2 pour cent de Be, constituant les dynodes suivant le traitement des surfaces, et l'influence de la tension sur le gain par etage sont discutees. Des resultats d'essais concernant: l'influence de la masse des ions sur le gain, le bruit de fond de l'appareil et la repartition en energie des impulsions de sortie sur un multiplicateur a gain eleve (q.q. 10{sup 7}) sont donnes. Enfin, sont rapportees les performances du multiplicateur. 1- pour un gain faible

  17. Etude de la qualité physico-chimique et biologique des eaux du ...

    African Journals Online (AJOL)

    Etude de la qualité physico-chimique et biologique des eaux du fleuve Niger à Niamey. ... le récepteur principal des rejets d'eaux usées de la ville de Niamey, capital du ... La description de ces taxons montre une variation de la structure des ...

  18. English Department Reforms at the Hautes Etudes Commerciales: Entering the Nineties.

    Science.gov (United States)

    Shanahan, Daniel

    1993-01-01

    Discusses the reforms made in the fall of 1990 in the English department at the Ecole Hautes Etudes Commerciales (Paris, France), which were based on the basis of a combination of literature-culture and second- and foreign-language acquisition pedagogical biases. (four references) (VWL)

  19. Contribution a l'etude des plantes alimentaires mineures dans la ...

    African Journals Online (AJOL)

    Contribution a l'etude des plantes alimentaires mineures dans la prefecture de Dankpen (Togo). AB Kebenzikato, S Akpavi, K Batawila, K Wala, M Dourma, K Kossi-Titrikou, KS Amouzou, I Butare, H Dantsey-Barry, K Akpagana ...

  20. 152 Etude de cas sur l'impact des amendements organiques vis-à ...

    African Journals Online (AJOL)

    john mukalay

    Etude de cas sur l'impact des amendements organiques vis-à-vis de la salinité en culture de bananier. Michel Mazinga KWEY1, Séverin Kalala BANZE2 et John Banza MUKALAY2*. 1Laboratoire des cultures in vitro, Département de phytotechnie, Faculté des sciences agronomiques,. Université de Lubumbashi, BP 1825, ...

  1. 186 Etude théorique du transport électronique par la simulation ...

    African Journals Online (AJOL)

    youness

    Choukria SAYAH et al. 186. Etude théorique du ... For that we carried out the microscopic simulations, based on the Monte. Carlo method. ... intervalles, piezoelectric as well as the interactions of alloy and on ionized impurities. ..... SAYA et al. 198. [5] - R. W. Hockney, J. W. Eastwood, "Computer simulation using particles",.

  2. Etude comparative de la flore aux abords des cours d'eau dans les ...

    African Journals Online (AJOL)

    Etude comparative de la flore aux abords des cours d'eau dans les zones hypo et hyper endémiques d'ulcère de Buruli en Côte d'Ivoire. C. Cisse Boni, E. Ehouman, D. Soro, M.W. Kone, A. Bakayoko, F. Dembele, K. Bauthire, M Dosso ...

  3. Rapid in situ gamma spectrometric determination of fallout radioactivity in the environment. Progress report

    International Nuclear Information System (INIS)

    Zombori, Peter

    1995-01-01

    The main aim of the present CRP is to identify the existing analytical methods and develop new ones, if possible, which provide rapid, reliable, and detailed information on the radioactive contamination of the environment after a major nuclear accident. Gamma spectrometry has long been regarded as one of the most applicable radioanalytical techniques but its use for environmental studies requires some further considerations. There are two possible approaches to measure environmental radioactivity: (a) taking samples of the different environmental media and measuring them in a laboratory or (b) taking the spectrometer to the place of interest and making in situ measurements. In the former case sampling is a crucial factor hindering the rapid analysis while the latter case is not always reliable due to the problems and uncertainties of the measurement interpretation. The application of in situ gamma spectrometry for the determination of environmental radioactivity has become increasingly attractive since the advent of the high resolution semiconductor gamma detectors, especially, more recently, portable high purity Ge diodes (HpGe). The applicability of this technique was very well proved after the Chernobyl reactor accident when in situ spectrometry played an important role in the rapid evaluation of the fall-out situation. Our measurements provided information on the amount and composition of the radioactive contamination of the ground surface already in the first hours. These measurements enabled us to predict the time variation of the environmental radioactivity after the stabilization of the situation. The portability of the system was an important factor in performing a rapid and efficient survey in different parts of the country. A serious disadvantage of this method is, however, that it requires some knowledge about the radionuclide distribution in the soil, which is normally determined by tedious and time consuming sample analysis of the different soil

  4. Baby fission chambers; Etude de chambres a fission miniatures

    Energy Technology Data Exchange (ETDEWEB)

    Guery, U; Tachon, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The present report is intended, on the one band, as a study of the main types of fission chambers produced to date, and on the other, to deal more generally with this type of detector. Originally, it was with a view to the charting of neutron scatter in 'Proserpine' that the authors undertook the study of these chambers. During the course of the task, it was considered worth tbe trouble of developing its scope to include a more general application: neutron scatter measurement of various energy neutrons within a reduced volume with slight local disturbance. (author) [French] Le present rapport se propose, d'une part, d'exposer les principales realisations de chambres a fission, d'autre part de faire une mise au point a caractere plus general sur ces detecteurs. Au depart, c'est surtout en vue des mesures de densite neutronique dans 'Proserpine' que les auteurs ont etudie ces chambres; au cours de la mise au point, il a paru interessant de developper leur etude pour des applications plus generales: mesures de densites de neutrons de differentes energies dans un element de volume tres reduit et avec faible perturbation locale. (auteur)

  5. SEPA (Service d'etudes, de Procedes et Analyses)

    International Nuclear Information System (INIS)

    2017-01-01

    The SEPA (Service d'etudes, de Procedes et Analyses), is an engineering department specializing in the analysis and processing of uranium ore. It comes from a long tradition of mining in France that began sixty-five years ago with the French Atomic Energy Commission (CEA) and that has been carried on by COGEMA and then Areva. SEPA brings a combination of experience and excellence to its activities thanks to its multidisciplinary staff (mineralogists, chemists, mechanical engineers, instrumentation specialists...), who come from diverse cultural backgrounds. Today, the SEPA draws on its wealth of know-how and expertise to devise and develop new methods for processing and valorizing ores everywhere in the world. Its mission is to: - Develop and conduct laboratory tests on methods for processing uranium and other valuable elements such as molybdenum, vanadium, rare earths, niobium, tantalum and thorium; - Analyze ores obtained during prospecting at locations all over the world; -Serve as an advisor in the commissioning of Areva industrial units and ore processing plants; -Perform environmental analyses during the full period of mining operations; -Conduct audits and provide advice on processes and analysis methods; -Carry out research and development in all aspects of minerals treatment (including the filing of patents). The SEPA combines experience, skills and a global approach to technologies used in ore processing. Its role is to continually improve the processes for extracting, processing and valorizing ores while protecting the environment

  6. Baby fission chambers; Etude de chambres a fission miniatures

    Energy Technology Data Exchange (ETDEWEB)

    Guery, U.; Tachon, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    The present report is intended, on the one band, as a study of the main types of fission chambers produced to date, and on the other, to deal more generally with this type of detector. Originally, it was with a view to the charting of neutron scatter in 'Proserpine' that the authors undertook the study of these chambers. During the course of the task, it was considered worth tbe trouble of developing its scope to include a more general application: neutron scatter measurement of various energy neutrons within a reduced volume with slight local disturbance. (author) [French] Le present rapport se propose, d'une part, d'exposer les principales realisations de chambres a fission, d'autre part de faire une mise au point a caractere plus general sur ces detecteurs. Au depart, c'est surtout en vue des mesures de densite neutronique dans 'Proserpine' que les auteurs ont etudie ces chambres; au cours de la mise au point, il a paru interessant de developper leur etude pour des applications plus generales: mesures de densites de neutrons de differentes energies dans un element de volume tres reduit et avec faible perturbation locale. (auteur)

  7. Selection and optimization of spectrometric amplifiers for gamma spectrometry: part II - linearity, live time correction factors and software

    International Nuclear Information System (INIS)

    Moraes, Marco Antonio Proenca Vieira de; Pugliesi, Reinaldo

    1996-01-01

    The objective of the present work was to establish simple criteria to choose the best combination of electronic modules to achieve an adequate high resolution gamma spectrometer. Linearity, live time correction factors and softwares of a gamma spectrometric system composed by a Hp Ge detector have been studied by using several kinds of spectrometric amplifiers: Canberra 2021, Canberra 2025, Ortec 673 and Tennelec 244 and the MCA cards Ortec and Nucleus. The results showed low values of integral non-linearity for all spectrometric amplifiers connected to the Ortec and Nucleus boards. The MCA card should be able to correct amplifier dead time for 17 kcps count rates. (author)

  8. The IDA-80 measurement evaluation programme on mass spectrometric isotope dilution analysis of uranium and plutonium. Vol. 1

    International Nuclear Information System (INIS)

    Beyrich, W.; Golly, W.; Spannagel, G.; Kernforschungszentrum Karlsruhe G.m.b.H.; Bievre, P. de; Wolters, W.

    1984-12-01

    The main objective was the acquisition of basic data on the uncertainties involved in the mass spectrometric isotope dilution analysis as applied to the determination of uranium and plutonium in active feed solutions of reprocessing plants. The element concentrations and isotopic compositions of all test materials used were determined by CBNM and NBS with high accuracy. The more than 60000 analytical data reported by the participating laboratories were evaluated by statistical methods applied mainly to the calculation of estimates of the variances for the different uncertainty components contributing to the total uncertainty of this analytical technique. Attention was given to such topics as sample ageing, influence of fission products, spike calibration, ion fractionation, Pu-241 decay correction, minor isotope measurement and errors in data transfer. Furthermore, the performance of the 'dried sample' technique and the 'in-situ' spiking method of undiluted samples of reprocessing fuel solution with U-235/Pu-242 metal alloy spikes, were tested successfully. Considerable improvement of isotope dilution analysis in this safeguards relevant application during the last decade is shown as compared to the results obtained in the IDA-72 interlaboratory experiment, organized by KfK in 1972 on the same subject. (orig./HP) [de

  9. Study and development of a method allowing the identification of actinides inside nuclear waste packages, by active neutron or photon interrogation and delayed gamma-ray spectrometry; Etude et developpement d'une technique de dosage des actinides dans les colis de dechets radioactifs par interrogation photonique ou neutronique active et spectrometrie des gamma retardes

    Energy Technology Data Exchange (ETDEWEB)

    Carrel, F

    2007-10-15

    An accurate estimation of the alpha-activity of a nuclear waste package is necessary to select the best mode of storage. The main purpose of this work is to develop a non-destructive active method, based on the fission process and allowing the identification of actinides ({sup 235}U, {sup 238}U, {sup 239}Pu). These three elements are the main alpha emitters contained inside a package. Our technique is based on the detection of delayed gammas emitted by fission products. These latter are created by irradiation with the help of a neutron or photon beam. Performances of this method have been investigated after an Active Photon or Neutron Interrogation (INA or IPA). Three main objectives were fixed in the framework of this thesis. First, we measured many yields of photofission products to compensate the lack of data in the literature. Then, we studied experimental performances of this method to identify a given actinide ({sup 239}Pu in fission, {sup 235}U in photofission) present in an irradiated mixture. Finally, we assessed the application of this technique on different mock-up packages for both types of interrogation (118 l mock-up package containing EVA in fission, 220 l mock-up package with a wall of concrete in photofission). (author)

  10. Beach sediments drift study by means of radioactive tracers; L'etude du transport littoral par la methode des traceurs radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Hours, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Jaffry, P [Electricite de France (EDF), 78 - Chatou (France). Lab. National d' Hydraulique

    1959-07-01

    The present state of the sediments drift studies by means of radioactive tracers is exposed. Various processes of labelling, immersion and detection, used in France and other countries, are reviewed. A more extended analysis of some aspects of the problem by the same authors can be found in 'La Houille Blanche', number 3, may-june 1959 (Rapport C.E.A. number 1269). (author) [French] L'etude du transport littoral des sediments et galets par la methode des traceurs radioactifs est en plein developpement. Le present rapport precise l'etat actuel de la question. Les techniques de marquage, d'immersion et de detection utilisees en France et a l'etranger sont decrites; une analyse plus detaillee de certains aspects de la question est presentee par les memes auteurs dans 'La Houille Blanche', numero 3, mai-juin 1959 (Rapport C.E.A. numero 1269). (auteur)

  11. Realization of a technical and economic referential of units of organic waste processing by methanization with and without biogas valorization. Study report; Realisation d'un referentiel technique et economique d'unites de traitement de dechets organiques par methanisation avec et sans valorisation du biogaz. Rapport d'etude

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Based on a literature survey and on the analysis of results obtained in operating installations in different countries (Germany, Denmark, France, Netherlands, and Switzerland), this study concerns the methanization of different substrates: domestic wastes, sludge from sewage processing plants, industrial wastes and effluents, agricultural wastes and effluents. This synthetic report describes the current status of methanization in terms of regulatory framework (for renewable energies, and for waste management, digestion residues and compost valorization in Europe and in the studied countries), and in terms of actual production and variety of base products. It gives an overview of the available technical solutions, of the products they use, and of the associated investment costs. These techniques are: completely stirred tank reactor (SCTR), upflow anaerobic sludge blanket (UASB), internal circulation (IC), 'piston', batch, percolation, contact, fluidized bed, and anaerobic filter. It reports a synthesis of answers given to a questionnaire about technical and economic aspects

  12. New quantitative and multi-modal approach for in-vivo studies of small animals: coupling of the {beta}-microprobe with magnetic techniques and development of voxelized rat and mouse phantoms; Nouvelle approche multimodale et quantitative pour les etudes in vivo chez le petit animal: couplage de la {beta}-MicroProbe aux techniques magnetiques et developpement de fantomes de rat et de souris voxelises

    Energy Technology Data Exchange (ETDEWEB)

    Desbree, A

    2005-09-15

    For the last 15 years, animal models that mimic human disorders have become ubiquitous participants to understand biological mechanisms and human disorders and to evaluate new therapeutic approaches. The necessity to study these models in the course of time has stimulated the development of instruments dedicated to in vivo small animal studies. To further understand physiopathological processes, the current challenge is to couple simultaneously several of these methods. Given this context, the combination of the magnetic and radioactive techniques remains an exciting challenge since it is still limited by strict technical constraints. Therefore we propose to couple the magnetic techniques with the radiosensitive Beta-Microprobe, developed in the IPB group and which shown to be an elegant alternative to PET measurements. In this context, the thesis was dedicated to the study of the coupling feasibility from a physical point of view, by simulation and experimental characterizations. Then, the determination of a biological protocol was carried out on the basis of pharmacokinetic studies. The experiments have shown the possibility to use the probe for radioactive measurements under intense magnetic field simultaneously to anatomical images acquisitions. Simultaneously, we have sought to improve the quantification of the radioactive signal using a voxelized phantom of a rat brain. Finally, the emergence of transgenic models led us to reproduce pharmacokinetic studies for the mouse and to develop voxelized mouse phantoms. (author)

  13. Etude aerodynamique d'un jet turbulent impactant une paroi concave

    Science.gov (United States)

    LeBlanc, Benoit

    Etant donne la demande croissante de temperatures elevees dans des chambres de combustion de systemes de propulsions en aerospatiale (turbomoteurs, moteur a reaction, etc.), l'interet dans le refroidissement par jets impactant s'est vu croitre. Le refroidissement des aubes de turbine permet une augmentation de temperature de combustion, ce qui se traduit en une augmentation de l'efficacite de combustion et donc une meilleure economie de carburant. Le transfert de chaleur dans les au bages est influence par les aspects aerodynamiques du refroidissement a jet, particulierement dans le cas d'ecoulements turbulents. Un manque de comprehension de l'aerodynamique a l'interieur de ces espaces confinees peut mener a des changements de transfert thermique qui sont inattendus, ce qui augmente le risque de fluage. Il est donc d'interet pour l'industrie aerospatiale et l'academie de poursuivre la recherche dans l'aerodynamique des jets turbulents impactant les parois courbes. Les jets impactant les surfaces courbes ont deja fait l'objet de nombreuses etudes. Par contre des conditions oscillatoires observees en laboratoire se sont averees difficiles a reproduire en numerique, puisque les structures d'ecoulements impactants des parois concaves sont fortement dependantes de la turbulence et des effets instationnaires. Une etude experimentale fut realisee a l'institut PPRIME a l'Universite de Poitiers afin d'observer le phenomene d'oscillation dans le jet. Une serie d'essais ont verifie les conditions d'ecoulement laminaires et turbulentes, toutefois le cout des essais experimentaux a seulement permis d'avoir un apercu du phenomene global. Une deuxieme serie d'essais fut realisee numeriquement a l'Universite de Moncton avec l'outil OpenFOAM pour des conditions d'ecoulement laminaire et bidimensionnel. Cette etude a donc comme but de poursuivre l'enquete de l'aerodynamique oscillatoire des jets impactant des parois courbes, mais pour un regime d'ecoulement transitoire, turbulent

  14. The study and the realization of radiation detectors made from polycrystalline diamond films grown by microwave plasma enhanced chemical vapour deposition technique; Etude et realisation de detecteurs de rayonnements a base de films de diamant polycristallin elabores par depot chimique en phase vapeur assiste par plasma micro-onde

    Energy Technology Data Exchange (ETDEWEB)

    Jany, Ch

    1998-10-29

    The aim of this work was to develop radiation detectors made from polycrystalline diamond films grown by microwave plasma enhanced chemical vapour deposition technique. The influence of surface treatments, contact technology and diamond growth parameters on the diamond detectors characteristics was investigated in order to optimise the detector response to alpha particles. The first part of the study focused on the electrical behaviour of as-deposited diamond surface, showing a p type conduction and its influence on the leakage current of the device. A surface preparation process was established in order to reduce the leakage current of the device by surface dehydrogenation using an oxidising step. Several methods to form and treat electrical contacts were also investigated showing that the collection efficiency of the device decreases after contact annealing. In the second part, we reported the influence of the diamond deposition parameters on the characteristics of the detectors. The increase of the deposition temperature and/or methane concentration was shown to lead {eta} to decrease. In contrast, {eta} was found to increase with the micro-wave power. The evolution of the diamond detector characteristics results from the variation in sp{sup 2} phases incorporation and in the crystallography quality of the films. These defects increase the leakage current and reduce the carrier mobility and lifetime. Measurements carried out on detectors with different thicknesses showed that the physical properties varies along the growth direction, improving with the film thickness. Finally, the addition of nitrogen (> 10 ppm) in the gas mixture during diamond deposition was found to strongly reduce the collection efficiency of the detectors. To conclude the study, we fabricated and characterised diamond devices which were used for thermal neutron detection and for the intensity and shape measurement of VUV and soft X-ray pulses. (author)

  15. High-efficient method for spectrometric data real time processing with increased resolution of a measuring channel

    International Nuclear Information System (INIS)

    Ashkinaze, S.I.; Voronov, V.A.; Nechaev, Yu.I.

    1988-01-01

    Solution of reduction problem as a mean to increase spectrometric tract resolution when it is realized using the digit-by-digit modified method and special strategy, significantly reducing the time of processing, is considered. The results presented confirm that the complex measurement tract plus microcomputer is equivalent to the use of the tract with a higher resolution, and the use of the digit-by-digit modified method permits to process spectrometric information in real time scale

  16. Comparative Ebulliometry: a Simple, Reliable Technique for Accurate Measurement of the Number Average Molecular Weight of Macromolecules. Preliminary Studies on Heavy Crude Fractions Ébulliométrie comparative : technique simple et fiable pour déterminer précisément la masse molaire moyenne en nombre des macromolécules. Etudes préliminaires sur des fractions lourdes de bruts

    Directory of Open Access Journals (Sweden)

    Behar E.

    2006-12-01

    Full Text Available This article is divided into two parts. In the first part, the authors present a comparison of the major techniques for the measurement of the molecular weight of macromolecules. The bibliographic results are gathered in several tables. In the second part, a comparative ebulliometer for the measurement of the number average molecular weight (Mn of heavy crude oil fractions is described. The high efficiency of the apparatus is demonstrated with a preliminary study of atmospheric distillation residues and resins. The measurement of molecular weights up to 2000 g/mol is possible in less than 4 hours with an uncertainty of about 2%. Cet article comprend deux parties. Dans la première, les auteurs présentent une comparaison entre les principales techniques de détermination de la masse molaire de macromolécules. Les résultats de l'étude bibliographique sont rassemblés dans plusieurs tableaux. La seconde partie décrit un ébulliomètre comparatif conçu pour la mesure de la masse molaire moyenne en nombre (Mn des fractions lourdes des bruts. Une illustration de l'efficacité de cet appareil est indiquée avec l'étude préliminaire de résidus de distillation atmosphérique et de résines. En particulier, la mesure de masses molaires pouvant atteindre 2000 g/mol est possible en moins de 4 heures avec une incertitude expérimentale de l'ordre de 2 %.

  17. Neutron scattering techniques for betaine calcium chloride dihydrate under applied external field (temperature, electric field and hydrostatic pressure); Etude par diffusion de neutrons du chlorure de calcium et de betaine dihydrate sous champ externe applique (temperature, champ electrique et pression hydrostatique)

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, O

    1997-11-17

    We have studied with neutron scattering techniques betaine calcium chloride dihydrate (BCCD), a dielectric aperiodic crystal which displays a Devil`s staircase type phase diagram made up of several incommensurate and commensurate phases, having a range of stability very sensitive to temperature, electric field and hydrostatic pressure. We have measured a global hysteresis of {delta}(T) of about 2-3 K in the two incommensurate phases. A structural study of the modulated commensurate phases 1/4 and 1/5 allows us to evidence that the atomic modulation functions are anharmonic. The relevance of the modelization of the modulated structure by polar Ising pseudo-spins is then directly established. On the basis of group theory calculation in the four dimensional super-space, we interpret this anharmonic modulation as a soliton regime with respect to the lowest-temperature non modulated ferroelectric phase. The continuous character of the transition to the lowest-temperature non modulated phase and the diffuse scattering observed in this phase are accounted for the presence of ferroelectric domains separated by discommensurations. Furthermore, we have shown that X-rays induce in BCCD a strong variation with time of irradiation of the intensity of satellite peaks, and more specifically for third order ones. This is why the `X-rays` structural model is found more harmonic than the `neutron` one. Under electric field applied along the vector b axis, we confirm that commensurate phases with {delta} = even/odd are favoured and hence are polar along this direction. We have evidenced at 10 kV / cm two new higher order commensurate phases in the phase INC2, corroborating the idea of a `complete` Devil`s air-case phase diagram. A phenomenon of generalized coexistence of phases occurs above 5 kV / cm. We have characterized at high field phase transitions between `coexisting` phases, which are distinguishable from classical lock-in transitions. Under hydrostatic pressure, our results

  18. The measurement of mass spectrometric peak height ratio of helium isotope in trace samples

    International Nuclear Information System (INIS)

    Sun Mingliang

    1989-01-01

    An experiment study on the measurement of mass spectrometric peak height ratio of helium isotope in the trace gaseous sample is discussed by using the gas purification line designed by the authors and model VG-5400 static-vacuum noble gas mass spectrometer imported and air helium as a standard. The results show that the amount of He and Ne in natural gas sample is 99% after purification. When the amount of He in Mass Spectrometer is more than 4 x 10 -7 cm 3 STP, it's sensitivity remains stable, about 10 -4 A/cm 3 STP He and the precision of 3 He/ 4 He ratio within the following 17 days is 1.32%. The 'ABA' pattern and experiment condition in the measurement of mass spectrometric peak height ratio of He isotope are presented

  19. New FORTRAN computer programs to acquire and process isotopic mass-spectrometric data

    International Nuclear Information System (INIS)

    Smith, D.H.

    1982-08-01

    The computer programs described in New Computer Programs to Acquire and Process Isotopic Mass Spectrometric Data have been revised. This report describes in some detail the operation of these programs, which acquire and process isotopic mass spectrometric data. Both functional and overall design aspects are addressed. The three basic program units - file manipulation, data acquisition, and data processing - are discussed in turn. Step-by-step instructions are included where appropriate, and each subsection is described in enough detail to give a clear picture of its function. Organization of file structure, which is central to the entire concept, is extensively discussed with the help of numerous tables. Appendices contain flow charts and outline file structure to help a programmer unfamiliar with the programs to alter them with a minimum of lost time

  20. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade boron carbide powder and pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Total Carbon by Combustion and Gravimetry 7-17 Total Boron by Titrimetry 18-28 Isotopic Composition by Mass Spectrometry 29-38 Chloride and Fluoride Separation by Pyrohydrolysis 39-45 Chloride by Constant-Current Coulometry 46-54 Fluoride by Ion-Selective Electrode 55-63 Water by Constant-Voltage Coulometry 64-72 Impurities by Spectrochemical Analysis 73-81 Soluble Boron by Titrimetry 82-95 Soluble Carbon by a Manometric Measurement 96-105 Metallic Impurities by a Direct Reader Spectrometric Method 106-114

  1. The interlaboratory experiment IDA-72 on mass spectrometric isotope dilution analysis. Vol. 2

    International Nuclear Information System (INIS)

    Beyrich, W.; Drosselmeyer, E.

    1975-07-01

    Volume II of the report on the IDA-72 experiment contains papers written by different authors on a number of special topics connected with the preparation, performance and evaluation of the interlaboratory test. In detail the sampling procedures for active samples of the reprocessing plant and the preparation of inactive reference and spike solution from standard material are described as well as new methods of sample conditioning by evaporation. An extra chapter is devoted to the chemical sample treatment as a preparation for mass spectrometric analysis of the U and Pu content of the solutions. Special topics are also methods for mass discrimination corrections, α-spectrometer measurements as a supplement for the determination of Pu-238 and the comparison of concentration determinations by mass spectrometric isotope dilution analysis with those performed by X-ray fluorescence spectrometry. The last part of this volume contains papers connected with the computerized statistical evaluation of the high number of data. (orig.) [de

  2. [Determination of trace cobalt in human urine by graphite furnace atomic absorption spectrometr].

    Science.gov (United States)

    Zhong, L X; Ding, B M; Jiang, D; Liu, D Y; Yu, B; Zhu, B L; Ding, L

    2016-05-20

    To establish a method to determine cobalt in human urine by graphite furnace atomic absorption spectrometry. Urine with 2% nitric acid diluted two-fold, to quantify the curve, graphite furnace atomic absorption spectrometric detection. Co was linear within 2.5~40.0 ng/ml with r>0.999. Spike experiment showed that Co received good recovery rate, which was 90.8%~94.8%. Intra-assay precisions were 3.2%~5.1% for Co, inter-assay precisions were 4.4%~5.2% for Co. The method by using graphite furnace atomic absorption spectrometr to determine urine Co was fast, accurate and with low matrix effect. It could meet the requirement in GBZ/T 210.5-2008.

  3. A Multifaceted Mass Spectrometric Method to Probe Feeding Related Neuropeptide Changes in Callinectes sapidus and Carcinus maenas

    Science.gov (United States)

    Zhang, Yuzhuo; DeLaney, Kellen; Hui, Limei; Wang, Junhua; Sturm, Robert M.; Li, Lingjun

    2018-05-01

    Food intake is regulated by various neuromodulators, including numerous neuropeptides. However, it remains elusive at the molecular and cellular level as to how these important chemicals regulate internal processes and which regions of the neuronal organs are responsible for regulating the behavior. Here we report a comparative neuropeptidomic analysis of the brain and pericardial organ (PO) in response to feeding in two well-studied crustacean physiology model organisms, Callinectes sapidus and Carcinus maenas, using mass spectrometry (MS) techniques. A multifaceted MS-based approach has been developed to obtain complementary information on the expression changes of a large array of neuropeptides in the brain and PO. The method employs stable isotope labeling of brain and PO extracts for relative MS quantitation, capillary electrophoresis (CE)-MS for fractionation and high-specificity analysis, and mass spectrometric imaging (MSI) for in-situ molecular mapping of peptides. A number of neuropeptides, including RFamides, B-type allatostatins (AST-B), RYamides, and orcokinins exhibit significant changes in abundance after feeding in this investigation. Peptides from the AST-B family found in PO tissue were shown to have both altered expression and localization changes after feeding, indicating that they may be a class of vital neuropeptide regulators involved in feeding behavior. [Figure not available: see fulltext.

  4. A Multifaceted Mass Spectrometric Method to Probe Feeding Related Neuropeptide Changes in Callinectes sapidus and Carcinus maenas

    Science.gov (United States)

    Zhang, Yuzhuo; DeLaney, Kellen; Hui, Limei; Wang, Junhua; Sturm, Robert M.; Li, Lingjun

    2018-02-01

    Food intake is regulated by various neuromodulators, including numerous neuropeptides. However, it remains elusive at the molecular and cellular level as to how these important chemicals regulate internal processes and which regions of the neuronal organs are responsible for regulating the behavior. Here we report a comparative neuropeptidomic analysis of the brain and pericardial organ (PO) in response to feeding in two well-studied crustacean physiology model organisms, Callinectes sapidus and Carcinus maenas, using mass spectrometry (MS) techniques. A multifaceted MS-based approach has been developed to obtain complementary information on the expression changes of a large array of neuropeptides in the brain and PO. The method employs stable isotope labeling of brain and PO extracts for relative MS quantitation, capillary electrophoresis (CE)-MS for fractionation and high-specificity analysis, and mass spectrometric imaging (MSI) for in-situ molecular mapping of peptides. A number of neuropeptides, including RFamides, B-type allatostatins (AST-B), RYamides, and orcokinins exhibit significant changes in abundance after feeding in this investigation. Peptides from the AST-B family found in PO tissue were shown to have both altered expression and localization changes after feeding, indicating that they may be a class of vital neuropeptide regulators involved in feeding behavior. [Figure not available: see fulltext.

  5. Determination of lithium and potassium in uranium oxide powders and pellets by Flame Atomic Emission Spectrometric method

    International Nuclear Information System (INIS)

    Jat, J.R.; Balaji Rao, Y.; Prasada Rao, G.; Prahlad, B.

    2012-01-01

    The present paper describes a method developed at Control Laboratory, NFC which includes prior separation of lithium and potassium from uranium matrix before their measurements. Solvent extraction, using Tri-n-Butyl Phosphate (TBP) in CCI 4 followed by Tri-n-Octyl Phosphine Oxide (TOPO) in CCI 4 , is employed for prior separation of Li and K. The resultant aqueous solution was analyzed by Flame-Atomic Emission Spectrometric (AES) method. Solvent extraction conditions are optimized for measurement of Li and K in the same aliquot. Experimental conditions such as instrument calibration, flame condition, fuel flow, sample flow rate through nebulizer, burner height etc. are also optimized. Under the optimal condition the detection limits achieved for lithium is 0.02 ppm and 0.2 ppm for potassium. A RSD of ± 3 % for Li at 0.05 ppm and ± 4% for K at 1 ppm level has been achieved in this method. The results of lithium in the sample are compared with the values obtained by Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES). Similarly, values of potassium are compared with Flame-Atomic Absorption Spectrometry (Flame-AAS) technique. The comparisons are in good agreement. The above method is simple, sensitive, reproducible and can be used for measurement of lithium and potassium in UO 2 powder and pellets on regular basis

  6. Gamma-spectrometric examination of hot particles emitted during the Chernobyl accident

    International Nuclear Information System (INIS)

    Balashazy, I.; Szabadine-Szende, G.; Loerinc, M.; Zombori, P.

    1987-05-01

    Ge(Li) gamma-spectrometric examination of hot particles prepared from air filtered dust of Budapest air after the Chernobyl accident is presented. The method of separating hot particles is described and their concentration in the air is determined. The radioactive isotope composition of hot particles is discussed and compared with that of dust samples. Finally, the inhalation probability and radiation burden of hot particles are evaluated. (author)

  7. A method for exploring the distribution of radioelements at depth using gamma-ray spectrometric data

    International Nuclear Information System (INIS)

    Li Qingyang

    1997-01-01

    Based on the inherent relation between radioelements and terrestrial heat flow, theoretically shows the possibility of exploring the distribution of radioelements at depth using gamma-ray spectrometric data, and a data-processing and synthesizing method has been adopted to deduce the calculation formula. The practical application in the uranium mineralized area No. 2801 in Yunnan Province proves that this method is of practical value, and it has been successfully applied to the data processing and good results have been obtained

  8. Mass-spectrometric investigation of rare earth acetylacetonates dipivaloylmethanates and their adducts

    International Nuclear Information System (INIS)

    Gavrishzhuk, E.M.; Dzyubenko, N.G.; Martynenko, L.I.

    1985-01-01

    Peculiarities of fragmentation of molecular ions of rare earth acetylacetonates and dipivaloylmethanates under mass-spectrometric investigation of these compounds as well as their adducts with o-phenanthroline, α,α'-dipyridyl, triphenylphosphine oxide are considered in the given review. Similar data for identical derivants of some transitions metals are presented. Data on potentials of appearance and dissociation energy of basic ions in mass-spectra of the studied β-diketonates are analyzed

  9. Uncertainty assessment in gamma spectrometric measurements of plutonium isotope ratios and age

    Energy Technology Data Exchange (ETDEWEB)

    Ramebaeck, H., E-mail: henrik.ramebeck@foi.se [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden); Nygren, U.; Tovedal, A. [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Ekberg, C.; Skarnemark, G. [Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden)

    2012-09-15

    A method for the assessment of the combined uncertainty in gamma spectrometric measurements of plutonium composition and age was evaluated. Two materials were measured. Isotope dilution inductively coupled plasma sector field mass spectrometry (ID-ICP-SFMS) was used as a reference method for comparing the results obtained with the gamma spectrometric method for one of the materials. For this material (weapons grade plutonium) the measurement results were in agreement between the two methods for all measurands. Moreover, the combined uncertainty in all isotope ratios considered in this material (R{sub Pu238/Pu239}, R{sub Pu240/Pu239}, R{sub Pu241/Pu239}, and R{sub Am241/Pu241} for age determination) were limited by counting statistics. However, the combined uncertainty for the other material (fuel grade plutonium) were limited by the response fit, which shows that the uncertainty in the response function is important to include in the combined measurement uncertainty of gamma spectrometric measurements of plutonium.

  10. Maintenance of stability in γ spectrometric system of low active and environmental samples - a practical experience

    International Nuclear Information System (INIS)

    Ravishankar, R.; Bandyopadhyay, T.; Sarkar, P.K.

    2011-01-01

    Particle Accelerators are becoming part of the society with more and more medical and Industrial types are added every year in addition to research type of accelerators. The outflow of materials to the public domain from such accelerator facilities need to checked carefully and must be released after ensuring the activities of such materials should not exceed the regulatory limits. Health Physics Unit, VECC is involved in analyzing food product samples, seized samples which are suspected to contain Uranium etc and other environmental samples in addition to analyzing radioactive materials evolved from Operational Health Physics work. Most of these analyses involve γ Spectrometric Systems of high efficiency and high resolution types. The efficacy of the analysis and results depends on various parameters of the spectrometric system. The electrical noise from the power supply system and other noises picked up, even in the range of a few milli volts range, have been found to affect the stability of the system. These effects may not be present initially during installation but may creep in due course due to various reasons including weather conditions, wear and tear etc. Unless these problems are attended in regular intervals, the stability of the spectrometric systems and hence the results of analysis of the low active and environmental samples, will not be satisfactory. The work describes the practical problems faced by Health Physics Unit, the methods employed in identifying the problems, the necessary remedial measures taken, the final outcome in the stability and the procedures framed in order to avoid in future. (author)

  11. Spectrometric aerial survey as a new tool for geological survey and mining prospecting

    International Nuclear Information System (INIS)

    Cambon, R.

    1997-01-01

    Airborne survey for radioactive minerals started around 1945. The limited sensitivity of the tools used, the difficulties found for the topographic and training effect corrections, made difficult the evaluation of the results. The technical progresses realized in the recent past years in electronic and computer sciences allowed to overcome these difficulties and gave to the method all its potentialities. With the aerial spectrometric survey, a new step was made, because this method can be used for other topics than radioactive prospection such as geological survey and mining prospection for metallic and industrial minerals. The spectrometric method is based on the possibility to measure photopeak energies (gamma radiation) emitted by radioactive minerals and discriminate between them those emitted by U238, TI 208 and K40 respectively daughter products of uranium, thorium and potassium. For airborne survey, one consider that measuring instruments will allow to pick-up 80% of the radioactive emission concerning the first 15 to 30 centimetres of ground (1 metre maximum). The use of this method for geological and mineral exploration is based on the assumption that different rock types or ore bearing rock types are composed of certain amounts of rock forming minerals which comprise specific quantities of radioactive elements such as potassium, uranium and thorium (cf: Gabelman 77). To be able to evaluate the results of the spectrometric survey it will be necessary to know roughly the behaviour of the different radioactive elements through a complete geological cycle. (author)

  12. Car-borne multichannel gamma-ray spectrometric system model CZD-6

    International Nuclear Information System (INIS)

    Lu Shili; Zhai Yugui; Ma Yanfang; Jiao Cangwen; Zhang Biao

    1998-01-01

    The car-borne multichannel gamma-ray spectrometric system Mode CZD-6 is composed of a HDY-256 of portable multichannel gamma-ray spectrometer developed by the Beijing Research Institute of Uranium Geology and a large volume scintillation detector. the position for each measurement point is determined by the GPS instrument. Its latitude and longitude, as well as measured 256 channels of γ-spectrometric data are collected by a notebook computer, which can show the 256 channels of spectra for each point during measuring processes. The complete system can be loaded in a field car. This system has been used to environmental radioactive monitoring after calibration by airborne radiometric models in Shijiazhuang, Hebei province. A lot of data confirm that the system works stably and reliably, and is a fast and advanced approach for environmental γ-spectrometric monitoring. It can be used not only to determination of contents of natural radioactive elements in environments, but also to monitoring nuclear pollution and emergency treatment in nuclear accidents significantly

  13. Study and installation of concrete shielding in the civil engineering of nuclear construction (1960); Etude et mise en place des betons de protection dans le genie civil des ouvrages nucleaires (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, F [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The object of this report is to give technical information about high density concretes which have become very important for radiation biological shielding. The most generally used heavy aggregates (barytes, ilmenite, ferrophosphorus, limonite, magnetite and iron punching) to make these concretes are investigated from the point of view prospecting and physical and chemical characteristics. At first, a general survey of shielding concretes is made involving the study of components, mixing and placing methods, then, a detailed investigation of some high density concretes: barytes concrete, with incorporation of iron punching or iron shot, ferrophosphorus concrete, ilmenite concrete and magnetite concrete, more particularly with regard to grading and mix proportions and testing process. To put this survey in concrete form, two practical designs are described such as they have been carried out at the Saclay Nuclear Station. Specifications are given for diverse concretes and for making the proton-synchrotron 'Saturne' shielding blocks. (author) [French] Ce rapport a pour objet de donner des precisions techniques au sujet des betons a haute densite qui ont pris une grande importance pour la protection biologique contre les rayonnements. Les agregats lourds les plus couramment utilises (barytine, ilmenite, ferrophosphore, limonite, magnetite et riblons) pour la fabrication de ces betons, sont examines du point de vue prospection et caracteristiques physiques et chimiques. On procede d'abord a une etude generale des betons de protection comprenant l'etude des constituants, de la confection et de la mise en place, ensuite, a un examen detaille de quelques betons a haute densite: betons a base de barytine, avec incorporation de riblons ou de grenaille de fonte, betons au ferrophosphore, a base d'ilmenite ou de magnetite, notamment en ce qui concerne la granulometrie, la composition, le dosage et les processus d'essais. Pour concretiser ces etudes, deux applications pratiques

  14. Study and installation of concrete shielding in the civil engineering of nuclear construction (1960); Etude et mise en place des betons de protection dans le genie civil des ouvrages nucleaires (1960)

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, F. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    The object of this report is to give technical information about high density concretes which have become very important for radiation biological shielding. The most generally used heavy aggregates (barytes, ilmenite, ferrophosphorus, limonite, magnetite and iron punching) to make these concretes are investigated from the point of view prospecting and physical and chemical characteristics. At first, a general survey of shielding concretes is made involving the study of components, mixing and placing methods, then, a detailed investigation of some high density concretes: barytes concrete, with incorporation of iron punching or iron shot, ferrophosphorus concrete, ilmenite concrete and magnetite concrete, more particularly with regard to grading and mix proportions and testing process. To put this survey in concrete form, two practical designs are described such as they have been carried out at the Saclay Nuclear Station. Specifications are given for diverse concretes and for making the proton-synchrotron 'Saturne' shielding blocks. (author) [French] Ce rapport a pour objet de donner des precisions techniques au sujet des betons a haute densite qui ont pris une grande importance pour la protection biologique contre les rayonnements. Les agregats lourds les plus couramment utilises (barytine, ilmenite, ferrophosphore, limonite, magnetite et riblons) pour la fabrication de ces betons, sont examines du point de vue prospection et caracteristiques physiques et chimiques. On procede d'abord a une etude generale des betons de protection comprenant l'etude des constituants, de la confection et de la mise en place, ensuite, a un examen detaille de quelques betons a haute densite: betons a base de barytine, avec incorporation de riblons ou de grenaille de fonte, betons au ferrophosphore, a base d'ilmenite ou de magnetite, notamment en ce qui concerne la granulometrie, la composition, le dosage et les processus d'essais. Pour concretiser ces

  15. Characterization of organic and conventional sweet basil leaves using chromatographic and flow-injection mass spectrometric (FIMS) fingerprints combined with principal component analysis

    Science.gov (United States)

    Lu, Yingjian; Gao, Boyan; Chen, Pei; Charles, Denys; Yu, Liangli (Lucy)

    2014-01-01

    Sweet basil, Ocimum basilicum., is one of the most important and wildly used spices and has been shown to have antioxidant, antibacterial, and anti-diarrheal activities. In this study, high performance liquid chromatographic (HPLC) and flow-injection mass spectrometric (FIMS) fingerprinting techniques were used to differentiate organic and conventional sweet basil leaf samples. Principal component analysis (PCA) of the fingerprints indicated that both HPLC and FIMS fingerprints could effectively detect the chemical differences in the organic and conventional sweet basil leaf samples. This study suggested that the organic basil sample contained greater concentrations of almost all the major compounds than its conventional counterpart on a per same botanical weight basis. The FIMS method was able to rapidly differentiate the organic and conventional sweet basil leaf samples (1 min analysis time), whereas the HPLC fingerprints provided more information about the chemical composition of the basil samples with a longer analytical time. PMID:24518341

  16. Vis-NIR spectrometric determination of Brix and sucrose in sugar production samples using kernel partial least squares with interval selection based on the successive projections algorithm.

    Science.gov (United States)

    de Almeida, Valber Elias; de Araújo Gomes, Adriano; de Sousa Fernandes, David Douglas; Goicoechea, Héctor Casimiro; Galvão, Roberto Kawakami Harrop; Araújo, Mario Cesar Ugulino

    2018-05-01

    This paper proposes a new variable selection method for nonlinear multivariate calibration, combining the Successive Projections Algorithm for interval selection (iSPA) with the Kernel Partial Least Squares (Kernel-PLS) modelling technique. The proposed iSPA-Kernel-PLS algorithm is employed in a case study involving a Vis-NIR spectrometric dataset with complex nonlinear features. The analytical problem consists of determining Brix and sucrose content in samples from a sugar production system, on the basis of transflectance spectra. As compared to full-spectrum Kernel-PLS, the iSPA-Kernel-PLS models involve a smaller number of variables and display statistically significant superiority in terms of accuracy and/or bias in the predictions. Published by Elsevier B.V.

  17. Radiolocation Techniques (Les Techniques de Radiolocalisation

    Science.gov (United States)

    1992-11-01

    Dr R. Klemm DrD Rother FGAN- FFM SEL/LS/E Neuenahrer Strasse 20 Lorenzstrasse 10 D-5307 Wachtberg 7 D-7000 Stuttgart 40 Germany Germany Prof. G...des solutions. accas I lFionograinme, donc: aui profil. Cat article rapporte tine partie des Etudes mendes an La indthodo proposde s’inspirc de cette

  18. Magnetic resonance studies of solid polymers; Etude des polymeres solides par resonance magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Lenk, R [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    This paper is a review of the application of nuclear magnetic resonance (NMR) to solid polymers. In the first, theoretical part, the elements of the theory of NMR, which are necessary for the study of the properties of solid polymers are discussed: the moments method, nuclear relaxation and the distribution of correlation times. In the second part the experimental results are presented. (author) [French] Cette etude est une recherche bibliographique sur l'application de la resonance magnetique nucleaire (RMN) aux polymeres solides. Dans la premiere partie theorique on discute les elements de la theorie de RMN, necessaires pour l'etude des proprietes des polymeres solides: la methode des moments, la relaxation nucleaire et la distribution des temps de correlation. La deuxieme partie presente les resultats des experiences. (auteur)

  19. Mass spectrometric based approaches in urine metabolomics and biomarker discovery.

    Science.gov (United States)

    Khamis, Mona M; Adamko, Darryl J; El-Aneed, Anas

    2017-03-01

    Urine metabolomics has recently emerged as a prominent field for the discovery of non-invasive biomarkers that can detect subtle metabolic discrepancies in response to a specific disease or therapeutic intervention. Urine, compared to other biofluids, is characterized by its ease of collection, richness in metabolites and its ability to reflect imbalances of all biochemical pathways within the body. Following urine collection for metabolomic analysis, samples must be immediately frozen to quench any biogenic and/or non-biogenic chemical reactions. According to the aim of the experiment; sample preparation can vary from simple procedures such as filtration to more specific extraction protocols such as liquid-liquid extraction. Due to the lack of comprehensive studies on urine metabolome stability, higher storage temperatures (i.e. 4°C) and repetitive freeze-thaw cycles should be avoided. To date, among all analytical techniques, mass spectrometry (MS) provides the best sensitivity, selectivity and identification capabilities to analyze the majority of the metabolite composition in the urine. Combined with the qualitative and quantitative capabilities of MS, and due to the continuous improvements in its related technologies (i.e. ultra high-performance liquid chromatography [UPLC] and hydrophilic interaction liquid chromatography [HILIC]), liquid chromatography (LC)-MS is unequivocally the most utilized and the most informative analytical tool employed in urine metabolomics. Furthermore, differential isotope tagging techniques has provided a solution to ion suppression from urine matrix thus allowing for quantitative analysis. In addition to LC-MS, other MS-based technologies have been utilized in urine metabolomics. These include direct injection (infusion)-MS, capillary electrophoresis-MS and gas chromatography-MS. In this article, the current progresses of different MS-based techniques in exploring the urine metabolome as well as the recent findings in providing

  20. Data processing in gamma spectrometry. Application to the decay schemes study; Traitement des informations en spectrometrie gamma application a l'etude de schemas de desintegration

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, J.P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires, departement d' electronique generale, service d' instrumentation nucleaire

    1968-06-01

    The purpose of this thesis is the processing of the data issued from a gamma spectrometer, and its applications to the decay schemes study. The mathematical analysis of the full energy peaks, in connection with the very good resolution of semi-conductor detectors, leads to a very accurate determination of the energies. The resolution of complex spectra by the least squares method, completed by a spectra generating process, allows the calculation of branching ratios. Then, the handling of the two dimensional experiments permits the coincidence exam. For each of these methods, the calculation principle, then the systematics tests realized in order to prove their validity and to determine their application ranges as well as some experimental results appropriate to illustrate their possibilities, are presented. The energies of some nuclides, frequently used as standards have been thus measured and the decay schemes of {sup 134}Cs and {sup 110m}Ag determined precisely. (author) [French] Cette these est consacree aux methodes de traitement des informations issues d'un spectrometre {gamma}, et a leur application a l'etude des schemas de desintegration: l'analyse mathematique des pics d'absorption totale, conjuguee avec l'excellent pouvoir de resolution des detecteurs semi-conducteurs, conduit a une determination tres precise des energies. La decomposition des spectres complexes par la methode des moindres carres, completee par un procede de generation de spectres, autorise le calcul des rapports de branchement. Enfin le depouillement des experiences biparametriques permet l'examen des coincidences. Pour chacune de ces methodes, on expose le principe des calculs et les essais systematiques effectues afin d'eprouver leur validite et de definir leurs domaines d'application, ainsi que quelques resultats experimentaux propres a illustrer leurs possibilites. Les energies de quelques isotopes utilises couramment comme etalons ont ainsi ete

  1. Seminar on Detectors and measurements techniques

    International Nuclear Information System (INIS)

    Holm, E.

    2002-01-01

    A Nordic Seminar on detectors and radionuclide measurement techniques was held in Lund, Sweden, May 3-4, 2001. The objective was to highlight recent progress and problems for techniques to study environmental radioactivity. It covered the aspect of detector sample geometry's and methods for evaluation of gamma gamma pulse height distributions. Within the field of alpha-spectrometric techniques gridded ionisation chambers, semiconductor detectors and a general description for analysis of alpha-particle-spectra were presented. Recent development in mass spectrometric techniques, AMS (Accelerator Mass Spectrometry) and ICPMS (Inductively Coupled Plasma mass Spectrometry) for long-lived radionuclides was described. Principles for analysis of beta particle emitters, especially by liquid scintillation were presented. The seminar also covered radiochemistry such advantages and disadvantages between ion exchange, solvent extraction and extraction chromatography. The use of controlled laboratory conditions for discerning the dynamics of accumulation in organisms was demonstrated. Other techniques such as neutron activation were also shown to be useful analytical tool for certain long-lived radionuclides. The results of the intercalibration exercises within the Nordic countries showed the importance of such analytical quality control. (au)

  2. Seminar on Detectors and measurements techniques

    Energy Technology Data Exchange (ETDEWEB)

    Holm, E. (ed.) [Risoe National Lab., Roskilde (Denmark)

    2002-07-01

    A Nordic Seminar on detectors and radionuclide measurement techniques was held in Lund, Sweden, May 3-4, 2001. The objective was to highlight recent progress and problems for techniques to study environmental radioactivity. It covered the aspect of detector sample geometry's and methods for evaluation of gamma gamma pulse height distributions. Within the field of alpha-spectrometric techniques gridded ionisation chambers, semiconductor detectors and a general description for analysis of alpha-particle-spectra were presented. Recent development in mass spectrometric techniques, AMS (Accelerator Mass Spectrometry) and ICPMS (Inductively Coupled Plasma mass Spectrometry) for long-lived radionuclides was described. Principles for analysis of beta particle emitters, especially by liquid scintillation were presented. The seminar also covered radiochemistry such advantages and disadvantages between ion exchange, solvent extraction and extraction chromatography. The use of controlled laboratory conditions for discerning the dynamics of accumulation in organisms was demonstrated. Other techniques such as neutron activation were also shown to be useful analytical tool for certain long-lived radionuclides. The results of the intercalibration exercises within the Nordic countries showed the importance of such analytical quality control. (au)

  3. Singing as a Therapeutic Agent, inThe Etude, 1891-1949.

    Science.gov (United States)

    Hunter

    1999-01-01

    The Etude music magazine, founded by Theodore Presser, was one of a number of popular music magazines published in the years prior to the establishment of the music therapy profession in 1950. During its publication run from 1883 to 1957, over 100 music therapy related articles appeared, including 13 on the health benefits of singing published between 1891 and 1949. Written by authors with diverse backgrounds, such as the famous Battle Creek, Michigan physician John Harvey Kellogg and Boston music critic Louis C. Elson, the articles contained consistent and adamant support regarding the health benefits of singing. The advantages described were both physical and psychological, and were recommended prophylactically for well persons and therapeutically for ill persons. Although the articles varied in perspective, from philosophical to theoretical to pedagogical, there is a consistent holistic medicine theme that appeared almost ahead of its time and no doubt linked to the push for vocal music education in that era. The importance of The Etude in promulgating ideas that helped shape the early practice of music therapy should not be underestimated. For much of its publication run The Etude was the largest music periodical in print, reaching its peak circulation of 250,000 copies per month in 1924.

  4. Etude du régime alimentaire des carnivores par des techniques moléculaires

    OpenAIRE

    Shehzad , Wasim

    2011-01-01

    Information on food webs is central to understand ecosystem functioning. It also provides information of ecosystem stability by evaluating the resource availability and use. Obtaining information on the diet can be critical especially when dealing with elusive carnivores, which are difficult to observe. However, these large carnivores are keystone species that influence the ecosystem through trophic cascades and maintain biodiversity. Thus, precise knowledge of their diet is a prerequisite fo...

  5. Non-Destructive X-ray Spectrometric and Chromatographic Analysis of Metal Containers and Their Contents, from Ancient Macedonia

    Directory of Open Access Journals (Sweden)

    Christos S. Katsifas

    2018-06-01

    Full Text Available This work describes a holistic archaeometric approach to ancient Macedonian specimens. In the region of the ancient city Lete, the deceased members of a rich and important family were interred in a cluster of seven tombs (4th century BC. Among the numerous grave goods, there was also a set of metal containers preserving their original content. The physico-chemical analysis of the containers and their contents was performed in order to understand the purpose of their use. For the containers, Energy Dispersive micro-X-Ray Fluorescence (EDμXRF spectroscopy was implemented taking advantage of its non-invasive character. The case (B35 and the small pyxis (B37 were made of a binary Cu-Sn alloy accompanied by a slight amount of impurities (Fe, Pb, As and the two miniature bowls were made of almost pure Cu. For the study of the contents, a combination of EDμXRF, X-Ray Diffraction (XRD, and Gas Chromatography—Mass Spectrometry (GC-MS was carried out. Especially for the extraction of the volatile compounds, the Solid Phase Micro-Extraction (SPME technique was used in the headspace mode. Because of the detection of Br, High Pressure Liquid Chromatography coupled to a Diode-Array-Detector (HPLC-DAD was implemented, confirming the existence of the ancient dye shellfish purple (porphyra in Greek. The analytical results of the combined implementation of spectrometric and chromatographic analytical techniques of the metal containers and their contents expand our knowledge about the pharmaceutical practices in Macedonia during the 4th century BC.

  6. Mass-spectrometric determination in individual coated HTR fuel particles

    International Nuclear Information System (INIS)

    Strigl, A.

    1976-11-01

    A method is described which allows the simultaneous determination of fission and reaction gases in individual coated particles at temperatures up to 2000 0 C. The particles are heated under high-vacuum in a micro resistance-furnace up to the desired temperature. After preselected times the particles are crushed by action of a pneumatic cylinder. The gases liberated are fed into a quadrupoleanalyzer where they are analyzed in a dynamic mode. A peak selector allows the simultaneous measurement of up to four gases. The method is used routinely for the determination of fission gases (Kr and Xe) and of carbon monoxide which is formed as a reaction gas from oxide fuel. Precision and accuracy are in the order of a few percent. Detection limits for routine measurements are about 10 -7 cm 3 (STP) for KR and Xe and 2 x 10 -5 cm 3 (STP) for CO but can be lowered by special techniques. (author)

  7. Systematic study of plasma and serum proteins in the pig; Etude systematique des proteines plasmatiques et seriques du porc

    Energy Technology Data Exchange (ETDEWEB)

    Daburon, F; Nizza, P; Hatchikian, C; Schmidt, J -P [Commissariat a l' Energie Atomique (France)

    1966-07-01

    This work has been carried out in the framework of the determination of the physiological constants of a normal pig. The aim was to study the serum and plasma proteins of this animal species, the ultimate object being to discover whether the qualitative and quantitative changes in these proteins can make a significant contribution to the establishment of a biological dosimetry for irradiated pigs. The serum and plasma from a normal pig were analyzed first by various simple electrophoretic methods and then by immuno-electrophoresis. As a result of the particular characteristics of pig serum we have gradually been led to make numerous modifications to the techniques used for human serums or for those of small laboratory animals. Much careful work and patience were required in order to obtain reproducible results. (authors) [French] Ce travail se situe dans le cadre de la determination des constantes physiologiques du porc normal. il s'agissait de proceder a l'etude des proteines seriques et plasmatiques de cette espece animale, le but ulterieur etant de savoir si les modifications qualitatives et quantitatives de ces proteines pourront representer une contribution valable a l'etablissement d'une dosimetrie biologique chez le porc irradie. Le serum et le plasma du porc normal ont ete analyses d'abord par diverses methodes electrophoretiques simples puis par immunoelectrophorese. Les caracteristiques particulieres du serum de porc nous ont conduits a apporter progressivement de nombreuses modifications aux techniques utilisees pour des serums humains ou de petits animaux de laboratoire. L'obtention de resultats reproductible a exige beaucoup de patience et de minutie. (auteurs)

  8. Systematic study of plasma and serum proteins in the pig; Etude systematique des proteines plasmatiques et seriques du porc

    Energy Technology Data Exchange (ETDEWEB)

    Daburon, F.; Nizza, P.; Hatchikian, C.; Schmidt, J.-P. [Commissariat a l' Energie Atomique (France)

    1966-07-01

    This work has been carried out in the framework of the determination of the physiological constants of a normal pig. The aim was to study the serum and plasma proteins of this animal species, the ultimate object being to discover whether the qualitative and quantitative changes in these proteins can make a significant contribution to the establishment of a biological dosimetry for irradiated pigs. The serum and plasma from a normal pig were analyzed first by various simple electrophoretic methods and then by immuno-electrophoresis. As a result of the particular characteristics of pig serum we have gradually been led to make numerous modifications to the techniques used for human serums or for those of small laboratory animals. Much careful work and patience were required in order to obtain reproducible results. (authors) [French] Ce travail se situe dans le cadre de la determination des constantes physiologiques du porc normal. il s'agissait de proceder a l'etude des proteines seriques et plasmatiques de cette espece animale, le but ulterieur etant de savoir si les modifications qualitatives et quantitatives de ces proteines pourront representer une contribution valable a l'etablissement d'une dosimetrie biologique chez le porc irradie. Le serum et le plasma du porc normal ont ete analyses d'abord par diverses methodes electrophoretiques simples puis par immunoelectrophorese. Les caracteristiques particulieres du serum de porc nous ont conduits a apporter progressivement de nombreuses modifications aux techniques utilisees pour des serums humains ou de petits animaux de laboratoire. L'obtention de resultats reproductible a exige beaucoup de patience et de minutie. (auteurs)

  9. Quantitative mass spectrometric analysis of glycoproteins combined with enrichment methods.

    Science.gov (United States)

    Ahn, Yeong Hee; Kim, Jin Young; Yoo, Jong Shin

    2015-01-01

    Mass spectrometry (MS) has been a core technology for high sensitive and high-throughput analysis of the enriched glycoproteome in aspects of quantitative assays as well as qualitative profiling of glycoproteins. Because it has been widely recognized that aberrant glycosylation in a glycoprotein may involve in progression of a certain disease, the development of efficient analysis tool for the aberrant glycoproteins is very important for deep understanding about pathological function of the glycoprotein and new biomarker development. This review first describes the protein glycosylation-targeting enrichment technologies mainly employing solid-phase extraction methods such as hydrizide-capturing, lectin-specific capturing, and affinity separation techniques based on porous graphitized carbon, hydrophilic interaction chromatography, or immobilized boronic acid. Second, MS-based quantitative analysis strategies coupled with the protein glycosylation-targeting enrichment technologies, by using a label-free MS, stable isotope-labeling, or targeted multiple reaction monitoring (MRM) MS, are summarized with recent published studies. © 2014 The Authors. Mass Spectrometry Reviews Published by Wiley Periodicals, Inc.

  10. Contribution to the micrographic study of uranium and its alloys; Contribution a l'etude micrographique de l'uranium et de ses alliages

    Energy Technology Data Exchange (ETDEWEB)

    Monti, H [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-06-15

    The present report is the result of research carried out by the radio metallurgy section, to perfect micrographic techniques applicable to the study of samples of irradiated uranium. In the first part of this work, two polishing baths are developed, having the qualities with a minimum of disadvantages inherent in their respective compositions: they are, on the one hand perchloric acid-ethanol mixtures, and on the other hand a phospho-chromic-ethanol bath. In the chapter following, the micrographic attack of uranium is studied. The only satisfactory process is oxidation by cathode bombardment forming epitaxic layers. In the third chapter, an attempt is made to characterise the different surface states of the uranium by dissolution potential measurements and electronic diffraction. In the fourth chapter are given some examples of the application of these techniques to the micrographic study of various uranium alloys. In an appendix, it is shown how the chemical oxidation after phospho-chromic-alcohol polishing allows the different inclusions present in the molten uranium to be distinguished. By X-ray diffraction, uranium monocarbide and mononitride inclusions in particular are characterised. (author) [French] Le present rapport est le resultat de recherches effectuees au service de radiometallurgie pour la mise au point de techniques micrographiques applicables a l'etude d'echantillons d'uranium irradie. Dans la premiere partie de ce travail, nous mettons au point deux bains de polissage qui presentent les qualites inherentes a leur composition respective, avec le minimum d'inconvenients: ce sont d'une part des melanges acide perchlorique-ethanol, et d'autre part un bain phospho-chromique-ethanol. Dans le chapitre suivant, nous etudions l'attaque micrographique de l'uranium. Seul le procede d'oxydation par bombardement cathodique formant des couches epitaxiques, est satisfaisant. Dans le troisieme chapitre, nous essayons de caracteriser les differents etats de

  11. Contribution to the micrographic study of uranium and its alloys; Contribution a l'etude micrographique de l'uranium et de ses alliages

    Energy Technology Data Exchange (ETDEWEB)

    Monti, H. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-06-15

    The present report is the result of research carried out by the radio metallurgy section, to perfect micrographic techniques applicable to the study of samples of irradiated uranium. In the first part of this work, two polishing baths are developed, having the qualities with a minimum of disadvantages inherent in their respective compositions: they are, on the one hand perchloric acid-ethanol mixtures, and on the other hand a phospho-chromic-ethanol bath. In the chapter following, the micrographic attack of uranium is studied. The only satisfactory process is oxidation by cathode bombardment forming epitaxic layers. In the third chapter, an attempt is made to characterise the different surface states of the uranium by dissolution potential measurements and electronic diffraction. In the fourth chapter are given some examples of the application of these techniques to the micrographic study of various uranium alloys. In an appendix, it is shown how the chemical oxidation after phospho-chromic-alcohol polishing allows the different inclusions present in the molten uranium to be distinguished. By X-ray diffraction, uranium monocarbide and mononitride inclusions in particular are characterised. (author) [French] Le present rapport est le resultat de recherches effectuees au service de radiometallurgie pour la mise au point de techniques micrographiques applicables a l'etude d'echantillons d'uranium irradie. Dans la premiere partie de ce travail, nous mettons au point deux bains de polissage qui presentent les qualites inherentes a leur composition respective, avec le minimum d'inconvenients: ce sont d'une part des melanges acide perchlorique-ethanol, et d'autre part un bain phospho-chromique-ethanol. Dans le chapitre suivant, nous etudions l'attaque micrographique de l'uranium. Seul le procede d'oxydation par bombardement cathodique formant des couches epitaxiques, est satisfaisant. Dans le troisieme chapitre, nous essayons

  12. Contribution to the study of plasmatic fibrinogen and serum albumin: effects of irradiation; Contribution a l'etude du fibrinogene et de la serum-albumine plasmatiques - effets de l'irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Suscillon, M [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Grenoble, 38 (France)

    1967-07-01

    The author studies the modifications of properties and structure of serum albumin and fibrinogen solution when subjected to radiation of low energy (X rays). On the other hand, two original techniques are exposed: 1. Amperometric determination of fibrin stabilizing factor or factor XIII of hemostasis. 2. Spectrophotometric study of fibrin formation kinetics. Then showing off and quantitative determination of platelets fibrinogen is exposed. (author) [French] L'auteur etudie les modifications des proprietes et de la structure des molecules de serum-albumine et de fibrinogene en solution soumise a un flux de RX de basse energie. D'autre part deux techniques originales sont exposees : 1. Dosage amperometrique du facteur stabilisant de la fibrine. 2. Etude spectrophotometrique de la cinetique de la fibro-formation. Enfin une mise en evidence et un dosage du fibrinogene plaquettaire sont presentes. (auteur)

  13. Contribution to the study of plasmatic fibrinogen and serum albumin: effects of irradiation; Contribution a l'etude du fibrinogene et de la serum-albumine plasmatiques - effets de l'irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Suscillon, M. [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Grenoble, 38 (France)

    1967-07-01

    The author studies the modifications of properties and structure of serum albumin and fibrinogen solution when subjected to radiation of low energy (X rays). On the other hand, two original techniques are exposed: 1. Amperometric determination of fibrin stabilizing factor or factor XIII of hemostasis. 2. Spectrophotometric study of fibrin formation kinetics. Then showing off and quantitative determination of platelets fibrinogen is exposed. (author) [French] L'auteur etudie les modifications des proprietes et de la structure des molecules de serum-albumine et de fibrinogene en solution soumise a un flux de RX de basse energie. D'autre part deux techniques originales sont exposees : 1. Dosage amperometrique du facteur stabilisant de la fibrine. 2. Etude spectrophotometrique de la cinetique de la fibro-formation. Enfin une mise en evidence et un dosage du fibrinogene plaquettaire sont presentes. (auteur)

  14. A Caenorhabditis elegans Mass Spectrometric Resource for Neuropeptidomics

    Science.gov (United States)

    Van Bael, Sven; Zels, Sven; Boonen, Kurt; Beets, Isabel; Schoofs, Liliane; Temmerman, Liesbet

    2018-01-01

    Neuropeptides are important signaling molecules used by nervous systems to mediate and fine-tune neuronal communication. They can function as neurotransmitters or neuromodulators in neural circuits, or they can be released as neurohormones to target distant cells and tissues. Neuropeptides are typically cleaved from larger precursor proteins by the action of proteases and can be the subject of post-translational modifications. The short, mature neuropeptide sequences often entail the only evolutionarily reasonably conserved regions in these precursor proteins. Therefore, it is particularly challenging to predict all putative bioactive peptides through in silico mining of neuropeptide precursor sequences. Peptidomics is an approach that allows de novo characterization of peptides extracted from body fluids, cells, tissues, organs, or whole-body preparations. Mass spectrometry, often combined with on-line liquid chromatography, is a hallmark technique used in peptidomics research. Here, we used an acidified methanol extraction procedure and a quadrupole-Orbitrap LC-MS/MS pipeline to analyze the neuropeptidome of Caenorhabditis elegans. We identified an unprecedented number of 203 mature neuropeptides from C. elegans whole-body extracts, including 35 peptides from known, hypothetical, as well as from completely novel neuropeptide precursor proteins that have not been predicted in silico. This set of biochemically verified peptide sequences provides the most elaborate C. elegans reference neurpeptidome so far. To exploit this resource to the fullest, we make our in-house database of known and predicted neuropeptides available to the community as a valuable resource. We are providing these collective data to help the community progress, amongst others, by supporting future differential and/or functional studies.

  15. A Caenorhabditis elegans Mass Spectrometric Resource for Neuropeptidomics

    Science.gov (United States)

    Van Bael, Sven; Zels, Sven; Boonen, Kurt; Beets, Isabel; Schoofs, Liliane; Temmerman, Liesbet

    2018-05-01

    Neuropeptides are important signaling molecules used by nervous systems to mediate and fine-tune neuronal communication. They can function as neurotransmitters or neuromodulators in neural circuits, or they can be released as neurohormones to target distant cells and tissues. Neuropeptides are typically cleaved from larger precursor proteins by the action of proteases and can be the subject of post-translational modifications. The short, mature neuropeptide sequences often entail the only evolutionarily reasonably conserved regions in these precursor proteins. Therefore, it is particularly challenging to predict all putative bioactive peptides through in silico mining of neuropeptide precursor sequences. Peptidomics is an approach that allows de novo characterization of peptides extracted from body fluids, cells, tissues, organs, or whole-body preparations. Mass spectrometry, often combined with on-line liquid chromatography, is a hallmark technique used in peptidomics research. Here, we used an acidified methanol extraction procedure and a quadrupole-Orbitrap LC-MS/MS pipeline to analyze the neuropeptidome of Caenorhabditis elegans. We identified an unprecedented number of 203 mature neuropeptides from C. elegans whole-body extracts, including 35 peptides from known, hypothetical, as well as from completely novel neuropeptide precursor proteins that have not been predicted in silico. This set of biochemically verified peptide sequences provides the most elaborate C. elegans reference neurpeptidome so far. To exploit this resource to the fullest, we make our in-house database of known and predicted neuropeptides available to the community as a valuable resource. We are providing these collective data to help the community progress, amongst others, by supporting future differential and/or functional studies. [Figure not available: see fulltext.

  16. Gamma Spectrometric Determination of U, Th, K and Some Geochemical Applications

    International Nuclear Information System (INIS)

    Dodona, A.; Tashko, A.

    2001-01-01

    The application of 'in situ' gamma-spectrometric method (''infinite'' environment), made possible the simultanious determination of U, Th and K. 4 channel gamma-spectrometric analyser with NaI(TI) scintilation counter crystal detector (103 cm 3 φ=50x50mm) was used to determin U, Th(more than 1-2 ppm) and K (more than 1%) in laboratory conditions. The detector was inserted into a lead camera and calibrated for measurement geometry with vessel of ''Marineli'' type of a 17o cm 3 volume. The study of main factors, which influence in the gamma spectrometric measurements, (the technical, physical, geometrical and time parameters) has been carried out. International standards of U, Th, K and internal monitoring standard samples are used for the calibration. External analytical control has been realized by other radiometric and chemical methods. The detection limits ( 1 ppm Th, 2ppm U and 1% K) and the relative errors (17-20% for 1-10 ppm U, Th and 10-15% for more than 10 ppm U, Th and more than 1% K) guarantee a quantitative analysis that may be used successfully in the geochemical studies. Some geochemical applications, based on the content of Th, U and Th/U ratio in rocks samples that we have we have analyzed with this method, are shown in this paper. U, Th and their ratio are used as trace elements to indicate the differences between the acidic magmatic rocks of Albania (Th/U ratio=2-6 and>10). The bimodal character of Th/U scattering in ignimbrides and monzonites (Korabi zone) shows that in addition to the ''normal'' rocks, there are also some ones enriched with Th, So, the differential analysis of Th, U, and K may be used as geochemical exploration criteria for the radioactive and non-radioactive mineralization, such as REE (Rare Earth Elements), phospghorites, bauxites, placers etc. (authors)

  17. Certification of model spectrometric alpha sources (MSAS) and problems of the MSAS system improvement

    International Nuclear Information System (INIS)

    Belyatskij, A.F.; Gejdel'man, A.M.; Egorov, Yu.S.; Nedovesov, V.G.; Chechev, V.P.

    1984-01-01

    Results of certification of standard spectrometric alpha sources (SSAS) of industrial production are presented: methods for certification by main radiation physical parameters: proper halfwidth of α-lines, activity of radionuclides in the source, energies of α-particle emitting sources and relative intensity of different energy α-particle groups - are analysed. The advantage for the SSAS system improvement - a set of model measures for α-radiation, a collection of interconnected data units on physical, engineering and design characteristics of SSAS, methods for their obtaining and determination, on instruments used, is considered

  18. Anomaly disentanglement on the basis of automatic processing of the aerial gamma-spectrometric survey data

    International Nuclear Information System (INIS)

    Perlovskij, V.A.; Zaika, S.D.; Lomtadze, V.V.

    1976-01-01

    Automated processing airborne gamma spectrometric data has been introduced with the use of the BESM-4 computer. Discrimination of anomalies is effected using a variable interval 200-300 m within which maximum values in the general counting channel and their coordinates are found; reference points are detected too against which one can determine the excess and amplitude of the anomalies. The discriminated anomalies are fixed on printer and charts of anomalies are constructed. The charts and tables characterizing the anomaly help in the identification of its potentialities and hence underlie a decision to start ground works

  19. Efficiency and attenuation correction factors determination in gamma spectrometric assay of bulk samples using self radiation

    International Nuclear Information System (INIS)

    Haddad, Kh.

    2009-02-01

    Gamma spectrometry forms the most important and capable tool for measuring radioactive materials. Determination of the efficiency and attenuation correction factors is the most tedious problem in the gamma spectrometric assay of bulk samples. A new experimental and easy method for these correction factors determination using self radiation was proposed in this work. An experimental study of the correlation between self attenuation correction factor and sample thickness and its practical application was also introduced. The work was performed on NORM and uranyl nitrate bulk sample. The results of proposed methods agreed with those of traditional ones.(author)

  20. Terverticillate Penicillia studied by direct electrospray mass spectrometric profiling of crude extracts: I. Chemosystematics

    DEFF Research Database (Denmark)

    Smedsgaard, Jørn; Frisvad, Jens Christian

    1997-01-01

    ) and Yeast Extract Sucrose agar (YES) directly into the electrospray source of the mass spectrometer. A data matrix was made from each substrate by transferring the complete centroid mass spectrum from 200 to 700 amu as 501 variables to individual columns. No attempt was made to identify ions in the mass......A chemosystematic study of 339 isolates from all known terverticillate Penicillium taxa was performed using electrospray mass spectrometric analysis of extractable metabolites. The mass profiles were made by injecting crude plug extracts made from cultures grown on Czapek Yeast Autolysate agar (CYA...

  1. A spectrometric approach in radiography for detection of materials by their effective atomic number

    CERN Document Server

    Ryzhikov, V D; Onyshchenko, G M; Lecoq, P; Smith, C F

    2009-01-01

    In this paper we report a spectrometric approach to dual-energy digital radiography that has been developed and applied to identify specific organic substances and discern small differences in their effective atomic number. An experimental setup has been designed, and a theoretical description proposed based on the experimental results obtained. The proposed method is based on the application of special reference samples made of materials with different effective atomic number and thickness parameters known to affect X-ray attenuation in the low-energy range. The results obtained can be used in the development of a new generation of multi-energy customs or medical X-ray scanners.

  2. Possibilities and limitations of analogue methods for studying the dynamics of nuclear power stations; Possibilites et limitations du calcul analogique pour les etudes dynamiques de centrales nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Caillet, C; Deat, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    1. Introduction: the present paper is devoted to analog simulation of problems related to nuclear reactors other than the simulation of the kinetic equations which is well known. 2. Thermodynamic problems: various problems relative to temperature evolution in a reactor, in a pipe, in an exchanger, in a turbine, are studied, and simulation techniques used by earlier authors are critically reviewed. 3. Pipe simulators: it is shown that this problem can be solved by the use of specialized simulators which will be described and analysed. 4. Rotating machine simulators: the particular aspect of rotating machine calculations introducing frequent use of diagrams is emphasized. A simulator requiring both digital and analogue methods is described. 5. The study of a nuclear power station: as an example it is proposed to discuss problems a rising in connection with the preceding elements (a, b, c, d) when simulating the behaviour of large nuclear plants. The part played by ordinary computing elements for the simulation of the different servomechanism transfer functions is considered and process of regulation is outlined. 6. Conclusion: the necessity of the use of high quality simulators and computers is underlined and the accuracy of the solutions is discussed. (author)Fren. [French] 1. Cinetique des reacteurs: la simulation des equations cinetiques d'un reacteur nucleaire ne pose desormais plus de probleme. II est donc possible de faire le point des differentes applications de la technique analogique dans ce domaine. 2. Les problemes thermodynamiques: on discute les differents problemes poses par l'evolution des temperatures dans un reacteur, dans une tuyauterie, dans un echangeur, dans une turbine, et on passe en revue les techniques de simulation proposees jusqu'a ce jour. 3s simulateurs de tuyauteries: on montre comment les differents problemes poses ci-dessus peuvent etre resolus, pour une classe tres vaste de reacteurs par l'emploi de simulateurs speciaux que l

  3. Composes inter-halogenes sous pression: etude des transformations structurales dans le monobromure d'iode sous forme dense

    Science.gov (United States)

    Bouchard, Alexandre

    La famille des composes halogenes et inter-halogenes representent des solides moleculaires adoptant des phases denses communes avec des solides moleculaires diatomiques comme l'azote et l'hydrogene. Parmi les transformations structurales et electroniques induites sous haute pression et observees dans ces solides, on note, entre autres, la dissociation moleculaire et la metallisation. De plus, l'etude des phases denses de l'iode a permis recemment l'observation d'une structure cristalline possedant une modulation dite incommensurable, c'est-a-dire une modulation possedant une periodicite differente de celle de la structure cristalline, jetant ainsi une lumiere nouvelle sur le processus de dissociation moleculaire dans les solides halogenes. Dans ce memoire, on propose d'etudier les changements structuraux dans monobromure d'iode (IBr), un compose inter-halogene possedant des proprietes structurales semblables a celles de deux composes halogenes, soit l'iode (I 2) et le brome (Br2) sous leur forme solide. Des experiences de diffraction des rayons X de poudres en utilisant un rayonnement synchrotron ont ete realisees a temperature ambiante sur l'IBr en variant la pression jusqu'aux environs de 60 GPa. La nature chimique particuliere du compose IBr a necessite la mise au point de techniques de chargement d'echantillon destinees a preserver l'integrite chimique de la substance utilisee. On rapporte egalement l'observation d'une phase de l'IBr presentant une modulation incommensurable. Les phases observees dans l'IBr permettent d'etablir des paralleles avec les phases denses rapportees dans I2 et Br2 par le biais d'un modele phenomenologique decrivant la sequence structurale des solides halogenes sous forme condensee.

  4. The downfall of TBA-354 - a possible explanation for its neurotoxicity via mass spectrometric imaging.

    Science.gov (United States)

    Ntshangase, Sphamandla; Shobo, Adeola; Kruger, Hendrik G; Asperger, Arndt; Niemeyer, Dagmar; Arvidsson, Per I; Govender, Thavendran; Baijnath, Sooraj

    2017-10-13

    1. TBA-354 was a promising antitubercular compound with activity against both replicating and static Mycobacterium tuberculosis (M.tb), making it the focal point of many clinical trials conducted by the TB Alliance. However, findings from these trials have shown that TBA-354 results in mild signs of reversible neurotoxicity; this left the TB Alliance with no other choice but to stop the research. 2. In this study, mass spectrometric methods were used to evaluate the pharmacokinetics and spatial distribution of TBA-354 in the brain using a validated liquid chromatography tandem-mass spectrometry (LCMS/MS) and mass spectrometric imaging (MSI), respectively. Healthy female Sprague-Dawley rats received intraperitoneal (i.p.) doses of TBA-354 (20 mg/kg bw). 3. The concentrationtime profiles showed a gradual absorption and tissue penetration of TBA-354 reaching the C max at 6 h post dose, followed by a rapid elimination. MSI analysis showed a time-dependent drug distribution, with highest drug concentration mainly in the neocortical regions of the brain. 4. The distribution of TBA-354 provides a possible explanation for the motor dysfunction observed in clinical trials. These results prove the importance of MSI as a potential tool in preclinical evaluations of suspected neurotoxic compounds.

  5. How mass spectrometric approaches applied to bacterial identification have revolutionized the study of human gut microbiota.

    Science.gov (United States)

    Grégory, Dubourg; Chaudet, Hervé; Lagier, Jean-Christophe; Raoult, Didier

    2018-03-01

    Describing the human hut gut microbiota is one the most exciting challenges of the 21 st century. Currently, high-throughput sequencing methods are considered as the gold standard for this purpose, however, they suffer from several drawbacks, including their inability to detect minority populations. The advent of mass-spectrometric (MS) approaches to identify cultured bacteria in clinical microbiology enabled the creation of the culturomics approach, which aims to establish a comprehensive repertoire of cultured prokaryotes from human specimens using extensive culture conditions. Areas covered: This review first underlines how mass spectrometric approaches have revolutionized clinical microbiology. It then highlights the contribution of MS-based methods to culturomics studies, paying particular attention to the extension of the human gut microbiota repertoire through the discovery of new bacterial species. Expert commentary: MS-based approaches have enabled cultivation methods to be resuscitated to study the human gut microbiota and thus to fill in the blanks left by high-throughput sequencing methods in terms of culturing minority populations. Continued efforts to recover new taxa using culture methods, combined with their rapid implementation in genomic databases, would allow for an exhaustive analysis of the gut microbiota through the use of a comprehensive approach.

  6. Mass spectrometric detection of siRNA in plasma samples for doping control purposes.

    Science.gov (United States)

    Kohler, Maxie; Thomas, Andreas; Walpurgis, Katja; Schänzer, Wilhelm; Thevis, Mario

    2010-10-01

    Small interfering ribonucleic acid (siRNA) molecules can effect the expression of any gene by inducing the degradation of mRNA. Therefore, these molecules can be of interest for illicit performance enhancement in sports by affecting different metabolic pathways. An example of an efficient performance-enhancing gene knockdown is the myostatin gene that regulates muscle growth. This study was carried out to provide a tool for the mass spectrometric detection of modified and unmodified siRNA from plasma samples. The oligonucleotides are purified by centrifugal filtration and the use of an miRNA purification kit, followed by flow-injection analysis using an Exactive mass spectrometer to yield the accurate masses of the sense and antisense strands. Although chromatography and sensitive mass spectrometric analysis of oligonucleotides are still challenging, a method was developed and validated that has adequate sensitivity (limit of detection 0.25-1 nmol mL(-1)) and performance (precision 11-21%, recovery 23-67%) for typical antisense oligonucleotides currently used in clinical studies.

  7. Assessment of current mass spectrometric workflows for the quantification of low abundant proteins and phosphorylation sites

    Directory of Open Access Journals (Sweden)

    Manuel Bauer

    2015-12-01

    Full Text Available The data described here provide a systematic performance evaluation of popular data-dependent (DDA and independent (DIA mass spectrometric (MS workflows currently used in quantitative proteomics. We assessed the limits of identification, quantification and detection for each method by analyzing a dilution series of 20 unmodified and 10 phosphorylated synthetic heavy labeled reference peptides, respectively, covering six orders of magnitude in peptide concentration with and without a complex human cell digest background. We found that all methods performed very similarly in the absence of background proteins, however, when analyzing whole cell lysates, targeted methods were at least 5–10 times more sensitive than directed or DDA methods. In particular, higher stage fragmentation (MS3 of the neutral loss peak using a linear ion trap increased dynamic quantification range of some phosphopeptides up to 100-fold. We illustrate the power of this targeted MS3 approach for phosphopeptide monitoring by successfully quantifying 9 phosphorylation sites of the kinetochore and spindle assembly checkpoint component Mad1 over different cell cycle states from non-enriched pull-down samples. The data are associated to the research article ‘Evaluation of data-dependent and data-independent mass spectrometric workflows for sensitive quantification of proteins and phosphorylation sites׳ (Bauer et al., 2014 [1]. The mass spectrometry and the analysis dataset have been deposited to the ProteomeXchange Consortium (http://proteomecentral.proteomexchange.org via the PRIDE partner repository with the dataset identifier PXD000964.

  8. Determination of plutonium-241 half-life by mass spectrometric measurement

    International Nuclear Information System (INIS)

    Hiyama, Takashi; Wada, Yukio; Onishi, Koichi

    1982-01-01

    Much data for Pu-241 half-life have been reported, but these values range from 13.8 years to 15.1 years depending on investigators. In order to define the half-life of Pu-241, the half-life was calculated by analyzing the mass spectrometry data obtained in the author's laboratory over the past six years on Plutonium Isotopic Standard Reference Materials prepared at the National Bureau of Standards (NBS). The sample used for this work consisted of SRM-947 and SRM-948 prepared at NBS. Before mass spectrometric analysis, the plutonium aliquot was separated from its Am-241 daughter by anion exchange chromatography, since Am-241 is not distinguished from Pu-241 in the mass spectrometer. 241 Pu/ 239 Pu and 241 Pu/ 240 Pu ratios were calculated from the values of mass spectrometric measurement. From the relation of log N to time, the half-life of Pu-241 was determined, based on the slope using a least squares fit. The half-life of Pu-241 was estimated to be 14.29+-0.15 years. (Yoshitake, I.)

  9. Etude de l'impact de la variation de la température sur les activités ...

    African Journals Online (AJOL)

    Etude de l'impact de la variation de la température sur les activités microbiennes : application à une population de Listeria monocytogenes CIP 7831, Listeria monocytogenes Scott A CIP 103575 et Escherichia coli ATCC 25922.

  10. Study of the point defects formed in cobalt by electron bombardment; Etude des defauts ponctuels crees par bombardement electronique dans le cobalt

    Energy Technology Data Exchange (ETDEWEB)

    Sulpice, G [Commissariat a l' Energie Atomique, 38 - Grenoble (France). Centre d' Etudes Nucleaires

    1968-12-01

    A study of the point defects formed in cobalt by electron bombardment is presented. The results are compared with those previously obtained for two other ferromagnetic metals of different structure, iron and nickel. In the first part we give a review of the literature concerning the creation of point defects, their contribution to resistivity and their annihilation mode in the three structure types. We then describe the experimental techniques adapted, in particular the study of the resistivity increase during a linear temperature rise. Our investigations concern the following, essential points : the observation of the successive annihilation stages of the point defects formed in pure cobalt, a study of the variations with respect to the doses and energy of the incident particles, and the determination of the annealing kinetics and the corresponding activation energies. The results are finally compared with the various models of point defect annihilation proposed for other metals: none of these interpretations is in perfect agreement with our results. In the case of cobalt we are thus led to modify the model proposed by our laboratory for iron an nickel. The difference between these three metals is explained by the anisotropic character of the cobalt matrix. (author) [French] Nous presentons une etude des defauts ponctuels crees par bombardement electronique dans le cobalt et comparons nos resultats a ceux obtenus precedemment dans deux autres metaux ferromagnetiques de structure differente, le fer et le nickel. Dans une premiere partie nous faisons une mise au point bibliographique comparee sur la creation des defauts, leur contribution a la resistivite et leur mode d'annihilation dans les trois types de structure. Nous decrivons ensuite les techniques experimentales mises au point, en particulier l'etude du revenu de la resistivite au cours d'une montee lineaire de temperature. Au cours de ce travail, nous avons mis en evidence les stades successifs d

  11. Contribution to the study of point defects formed in nickel by electron bombardment; Contribution a l'etude des defauts ponctuels crees par bombardement electronique dans le nickel

    Energy Technology Data Exchange (ETDEWEB)

    Oddou, J L [Commissariat a l' Energie Atomique, 38 - Grenoble (France). Centre d' Etudes Nucleaires

    1968-12-01

    After a short account of the experimental techniques employed in our studies, the experimental results obtained on pure nickel samples are exposed. The apparition of the successive annihilation stages of point defects created by electron bombardment is established by isochronal heat treatments: the annihilation kinetics and the corresponding activation energies are determined. The effect of the incident particle doses is also studied. The experimental results are then compared with R.A. Johnson's theoretical calculations of the stability and the migration of point defects in nickel, and taking into account the results obtained by Peretto in magnetic after effect measurements. This leads us to a model in good agreement with calculations and experiment for the first stages. In a second chapter the behaviour of nickel doped by certain impurities is studied. First, the results concerning the rate of increase of resistivity (function of sample purity) is investigated. Two possible explanations of the observed phenomenon are proposed: either a deviation with respect to Mathiessen's law, or an increase of the number of defects formed in the presence of impurity atoms. Finally, a study of the resistivity recovery of the doped samples permits us to suggest an order of magnitude for the binding energy interstitial/impurity atom in the nickel matrix. (author) [French] Apres avoir brievement rappele les techniques experimentales que nous avons utilisees pour cette etude, nous exposons les resultats experimentaux obtenus sur des echantillons de nickel pur. Les stades successifs d'annihilation des defauts ponctuels crees par bombardement electronique sont mis en evidence par traitements thermiques isochrones; les cinetiques de disparition, et les energies d'activation correspondantes sont determinees. Nous etudions egalement l'effet de la dose des particules incidentes. Les resultats experimentaux sont ensuite compares avec les calculs theoriques de R.A JOHNSON sur la stabilite

  12. Bio-metric study of pig karyotype; Etude biometrique du caryotype du porc

    Energy Technology Data Exchange (ETDEWEB)

    Haag, J; Lacourly, N; Nizza, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    This study has a twofold purpose, the former is to determine the swine karyotype as accurately as possible, the latter is to try and develop a method of automatic classification and to show its possibilities and limits. (authors) [French] Cette etude a un double objet: d'une part, de definir de la facon aussi precise que possible le caryotype du porc et d'autre part, de tenter une methode de classification automatique et d'en montrer les possibilites ainsi que les limites. (auteurs)

  13. Gas chromatography of organic microcontaminants using atomic emission and mass spectrometric detection combined in one instrument (GC-AED/MS)

    NARCIS (Netherlands)

    Mol, H.G.J.; Hankemeier, T.; Brinkman, U.A.T.

    1999-01-01

    This study describes the coupling of an atomic-emission detector and mass-spectrometric detector to a single gas chromatograph. Splitting of the column effluent enables simultaneous detection by atomic-emission detection (AED) and mass spectrometry (MS) and yields a powerful system for the target

  14. Determination of radium isotopes by BaSO4 coprecipitation for the preparation of alpha-spectrometric sources

    International Nuclear Information System (INIS)

    Lozano, J.C.; Fernandez, F.; Gomez, J.M.G.

    1997-01-01

    A coprecipitation procedure for the preparation of α-spectrometric sources for radium, using BaSO 4 as carrier, has been applied to the determination of alpha radium isotopes in water samples. The use of 133 Ba as a suitable tracer for radium determination and possible losses of radon isotopes from the sources are studied and discussed. (author)

  15. Mass spectrometric confirmation criterion for product-ion spectra generated in flow-injection analysis. Environmental application

    NARCIS (Netherlands)

    Geerdink, R.B.; Niessen, W.M.A.; Brinkman, U.A.T.

    2001-01-01

    The suitability of a confirmation criterion recently recommended in the Netherlands for gas chromatography with mass spectrometric detection (GC-MS), was evaluated for flow-injection analysis (FIA) with atmospheric pressure chemical ionisation MS-MS detection. The main feature of the criterion is

  16. A liquid chromatography-mass spectrometric method for the determination of oak moss allergens atranol and chloroatranol in perfumes

    DEFF Research Database (Denmark)

    Bossi, Rossana; Rastogi, Suresh Chandra; Bernard, Guillaume

    2004-01-01

    This paper describes a validated liquid chromatographic-tandem mass spectrometric method for quantitative analysis of the potential oak moss allergens atranol and chloroatranol in perfumes and similar products. The method employs LC-MS-MS with electrospray ionization (ESI) in negative mode...

  17. Determination of isotope fractionation effect using a double spike (242Pu+240Pu) during the mass spectrometric analysis of plutonium

    International Nuclear Information System (INIS)

    Chitambar, S.A.; Parab, A.R.; Khodade, P.S.; Jain, H.C.

    1986-01-01

    Isotope fractionation effect during the mass spectrometric analysis of plutonium has been investigated using a double spike ( 242 Pu+ 240 Pu) and the determination of concentration of plutonium in dissolver solution of irradiated fuel is reported. (author). 6 refs., 2 tables

  18. Spectrometric gamma radiation of shale cores applied to sweet spot discrimination in Eastern Pomerania, Poland

    Science.gov (United States)

    Skupio, Rafal; de Alemar Barberes, Gabriel

    2017-12-01

    This paper describes the application and calculation of hydrocarbon anomalies in two different boreholes located in Eastern Pomerania (northern Poland). Spectrometric data from borehole geophysical probe (borehole 1) and portable gamma logger (borehole 2) were used to analyze shale formations. The results from borehole 1 presented a statistically significant, moderate correlation between calculated hydrocarbon anomalies and hydrocarbon saturation data obtained from well log interpretation. Borehole 2 has been analyzed focusing on the gamma radiation of the core samples, and the positive results of borehole 1. Hydrocarbon anomalies calculated from spectral gamma radiation are reliable indicators of sweet spots, based solely on a cursory evaluation of core measurements. These preliminary information acquired from gamma-ray measurements could help increase sampling precision of further geochemical analysis.

  19. Mass spectrometric analysis of EPO IEF-PAGE interfering substances in nitrile examination gloves.

    Science.gov (United States)

    Reichel, Christian

    2012-10-01

    Direct detection of doping with recombinant erythropoietins (rhEPO) is accomplished by isoelectric focusing (IEF) or sodium dodecylsulfate (SDS) polyacrylamide gel electrophoresis (PAGE). In a recent publication, Lasne et al. (Electrophoresis 2011, 32, 1444) showed that improper use of nitrile examination gloves during sample collection, sample preparation, and IEF-PAGE may lead to distorted or absent EPO IEF-profiles. In order to clarify which substances are responsible for this observation, a mass spectrometric study on water extractable compounds found in nitrile gloves was performed. Several substance classes were shown to be present, among them polyethylene glycols (PEG), anionic and nonionic surfactants, as well as alcohol ethoxylates and plasticizers. It could be demonstrated that alkylbenzenesulfonates, the main category of detectable anionic detergents, and among them sodium dodecylbenzenesulfonate (SDBS) and its homologs, are the prime reason for the interference of nitrile gloves with EPO IEF-PAGE. Copyright © 2012 John Wiley & Sons, Ltd.

  20. Levelling Airborne and Ground Gamma-Ray Spectrometric Data to Assist Uranium Exploration

    Energy Technology Data Exchange (ETDEWEB)

    Matolin, M., E-mail: matolin@natur.cuni.cz [Charles University, Prague (Czech Republic); Minty, B. [Geoscience Australia, Canberra (Australia)

    2014-05-15

    Geophysical methods can be used for mapping in both 2 and 3 dimensions, as well as the direct detection of ore bodies. The gamma-ray spectrometric method is an efficient method for the regional assessment of uranium potential and the detection of surface mineralization. However, the full potential of the method can only be realized when the data are adequately standardized. Examples of this standardization at both regional and local scales are dealt in this paper. At a regional scale, it is shown how the levelling of airborne gamma-ray spectrometry data over Australia increases the value of the resulting data, and on a local scale a geometrical correction for ground gamma-ray spectrometry in shallow holes that improves the accuracy of measurements is introduced. (author)

  1. Calibration of a leak detection spectrometer; Calibration d'un spectrometre detecteur de fuites

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This paper describes a study of the possible methods for calibrating a leak detection spectrometer, and the estimation of outputs from the leaks is considered. With this in mind the question of sensitivity of leak detection is tackled on a very general level; first the sensitivity of the isolated instrument is determined, and then the sensitivity of an instrument connected to an installation where leaks may be suspected. Finally, practical solutions are proposed. (author) [French] Dans cet article, nous etudions les methodes possibles de calibration d'un spectrometre detecteur de fuites et nous envisageons l'evaluation des debits de fuites trouves. Pour cela, nous abordons la notion de sensibilite de la detection de fuite sur un plan tres general; d'abord nous determinons la sensibilite de l'appareil isole, ensuite la sensibilite d'un appareil connecte sur une installation ou l'on cherche les fuites. Enfin, nous preconisons des solutions pratiques. (auteur)

  2. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover procedures for subsampling and for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride UF6. Most of these test methods are in routine use to determine conformance to UF6 specifications in the Enrichment and Conversion Facilities. 1.2 The analytical procedures in this document appear in the following order: Note 1—Subcommittee C26.05 will confer with C26.02 concerning the renumbered section in Test Methods C761 to determine how concerns with renumbering these sections, as analytical methods are replaced with stand-alone analytical methods, are best addressed in subsequent publications. Sections Subsampling of Uranium Hexafluoride 7 - 10 Gravimetric Determination of Uranium 11 - 19 Titrimetric Determination of Uranium 20 Preparation of High-Purity U3O 8 21 Isotopic Analysis 22 Isotopic Analysis by Double-Standard Mass-Spectrometer Method 23 - 29 Determination of Hydrocarbons, Chlorocarbons, and Partially Substitut...

  3. Characterisation of radioactive contaminated materials by combined radiometric and spectrometric methods

    International Nuclear Information System (INIS)

    Dulama, C.; Toma, A.; Dobrin, R.; Ciocîrlan, C.; Stoica, S.; Valeca, M.; Popescu, I. I.

    2013-01-01

    In the present paper, a combined analytical methodology is described, for characterization of radioactive contaminated materials. The subject of testing activities was a set of solutions provided by the Cernavoda NPP, which are originating from processes of radiological survey of workplaces in the plant. In the introduction section, a theoretical approach was given to the origin and nature of main radionuclides occurring in the primary cooling system of the nuclear power plant, with the aim to establish selection criteria and performance requirements for the analytical methods to be used in the development of the characterization methodology. A combination of radiometric and spectrometric methods was selected, based on gross beta counting, high resolution gamma-ray spectrometry and liquid scintillation counting. (authors)

  4. Anomalies from aerial spectrometric and total count radiometric surveys in the southeastern United States

    International Nuclear Information System (INIS)

    Lee, C.H.; Lawton, D.E.

    1978-01-01

    Aerial radiometric reconnaissance surveys are conducted because of their cost, time, and manpower savings compared to surface studies. Two types of aerial surveys are being flown in the southeastern United States: total count gamma-ray surveys for the Coastal Plains Regional Commission and the US Geological Survey, and differential gamma-ray spectrometric surveys for the US Department of Energy. Anomalous radioactivity detected during aerial surveys is related to higher concentrations of naturally occurring uranium, or to cultural activities, natural causes, or mapping errors which simulate real uranium anomalies. Each anomaly should be ground checked; however, several types of anomalies may be eliminated by evaluation of the aerial data in the office if field time is limited

  5. Absolute analysis of uranium isotopic concentrations with a gas ion source mass spectrometer; Analyses absolues des concentrations isotopiques de l'uranium par spectrometre de masse equipe d'une source a gaz

    Energy Technology Data Exchange (ETDEWEB)

    Chaussy, L.; Boyer, R. [Commissariat a l' Energie Atomique, Pierrelatte (France)

    1969-07-01

    Mass spectrometer with electronic bombardment ions source for routine uranium isotopic analysis are used like relative measurements apparatus. We show that such mass spectrometers can be used for absolute measurements with a very high sensitivity and precision which are ten times better than theses of thermo-ionic ions source mass spectrometer. We examine the causes of systematic errors and we give experimental data. In particular natural uranium sample used as reference give: U{sub 5} = 0.7202 {+-} 0.0005 atoms per cent; U{sub 4} = 0.00552 {+-} 0.0003 atoms per cent. The use of this method is justified for standards control. (authors) [French] Les spectrometres de masse a source par bombardement electronique pour l'analyse de l'uranium sous forme d'hexafluorure, sont utilises en routine comme des appareils de mesure relative. On montre que l'on peut utiliser de tels appareils pour effectuer des mesures absolues avec une excellente sensibilite et reproductibilite, dix fois superieure a celle des spectrometres a source thermoionique. On examine en detail les causes d'erreurs systematiques et on donne des resultats experimentaux. En particulier, l'analyse d'un echantillon d'uranium naturel donne: U{sub 5} = 0.7202 {+-} 0.0005 atomes pour cent; U{sub 4} = 0.00552 {+-} 0.0003 atomes pour cent. La technique de mesure est utile pour le controle d'etalons isotopiques. (auteurs)

  6. Knudsen cell mass spectrometric study of the Cs2IOH(g) molecule thermodynamics

    International Nuclear Information System (INIS)

    Roki, F-Z.; Ohnet, M-N.; Fillet, S.; Chatillon, C.; Nuta, I.

    2013-01-01

    Highlights: • The pronounced ionic character leads to only dissociative ionization processes. • Ions formed are same as those coming from pure dimmers. • De-convolution of the ions origin needs accurate thermodynamic values for the pure gas phase. • Mass spectrometric interpretation has to be performed gradually and as a function of suitable condensed compositions. • Thermal functions have to be fully estimated. -- Abstract: The gas phase of the CsI + CsOH system is analyzed by high temperature Knudsen cell mass spectrometry in order to confirm the existence of the Cs 2 IOH(g) complex molecule. The mass spectrometric analysis is quite complex since such molecules undergo dissociative ionization into fragment ions that mix with the same ions from dimers of the pure compounds in the same vapor phase. Varying the chemical conditions for vaporization by using different CsI + CsOH mixture contents showed that the ionization of the Cs 2 IOH(g) molecule led to five different fragment ions, Cs 2 OH + , Cs 2 I + , Cs + , CsOH + and CsI + . This complex ionization pattern was studied in relation with previous assessed values for the vaporization of CsOH and CsI pure compounds in which monomer and dimer molecules are predominant. The equilibrium constant for the reaction CsI(g) + CsOH(g) = Cs 2 IOH(g) was determined and, after modeling the structure of the Cs 2 IOH molecule, the enthalpy of formation was determined using the third law of thermodynamics, as follows: Δ f H°(Cs 2 IOH, g, 298.15 K) = −578 ± 14.7 kJ · mole −1

  7. GNU polyxmass: a software framework for mass spectrometric simulations of linear (bio-polymeric analytes

    Directory of Open Access Journals (Sweden)

    Rusconi Filippo

    2006-04-01

    Full Text Available Abstract Background Nowadays, a variety of (bio-polymers can be analyzed by mass spectrometry. The detailed interpretation of the spectra requires a huge number of "hypothesis cycles", comprising the following three actions 1 put forth a structural hypothesis, 2 test it, 3 (invalidate it. This time-consuming and painstaking data scrutiny is alleviated by using specialized software tools. However, all the software tools available to date are polymer chemistry-specific. This imposes a heavy overhead to researchers who do mass spectrometry on a variety of (bio-polymers, as each polymer type will require a different software tool to perform data simulations and analyses. We developed a software to address the lack of an integrated software framework able to deal with different polymer chemistries. Results The GNU polyxmass software framework performs common (bio-chemical simulations–along with simultaneous mass spectrometric calculations–for any kind of linear bio-polymeric analyte (DNA, RNA, saccharides or proteins. The framework is organized into three modules, all accessible from one single binary program. The modules let the user to 1 define brand new polymer chemistries, 2 perform quick mass calculations using a desktop calculator paradigm, 3 graphically edit polymer sequences and perform (bio-chemical/mass spectrometric simulations. Any aspect of the mass calculations, polymer chemistry reactions or graphical polymer sequence editing is configurable. Conclusion The scientist who uses mass spectrometry to characterize (bio-polymeric analytes of different chemistries is provided with a single software framework for his data prediction/analysis needs, whatever the polymer chemistry being involved.

  8. Sr isotope geochemistry of East Alpine mineral deposits and mass spectrometric analyses of fluid inclusions

    International Nuclear Information System (INIS)

    Grum, W.

    1995-05-01

    Strontium isotope geochemistry and deformational history of selected carbonate-hosted deposits from different tectonic positions in the Eastern Alps were studied. In this context an equipment has been constructed to analyze the composition of volatile components of fluid inclusions (FI). Based on the results of Sr-isotopic investigations two groups of deposits are discriminated: Deposits formed by formation waters and/or metamorphogenic fluids: Tux (magnesite, scheelite), Otterzug (barite), Lassing (magnesite), Rabenwald (talc), Laussa and Mooseck (fluorite). The mineralizing fluids are derived from different sedimentary rock series and therefore 87 Sr/ 86 Sr-ratios vary between 0.707 and 0.719. Deposits situated along fault zones: Lassing (talc), Gasteiner Tal (Silberpfennig area; gold), Schlaining (stibnite) and Waldenstein (specularite). Sr isotope ratios of the mineralizing fluids from Lassing, Waldenstein and Schlaining ranges from 0.7112 to 0.7127 and are therefore thought to have scavenged the East Alpine crystalline. The mineralizing solutions of the Gasteiner Tal deposit may either have equilibrated with low radiogenic sedimentary or with (ultra-)basic rocks. A cracking chamber has been constructed in order to open FI by cracking for mass spectrometric analysis of volatile components. Gases are analysed using a quadrupole mass spectrometer. The desorption of gas from metal and sample surfaces during cracking can be neglected. The amount of gas released from the mineral lattices was studied. With that fast method ore bearing from barren host rocks have been distinguished by different composition of the FI at the Brixlegg barite mineralization (Eastern Alps). Within the Galway fluorite deposit (Ireland) different fluids were involved and mass spectrometric analysis were carried out to characterize these different fluids and to identify their origin. (author)

  9. Increased Protein Structural Resolution from Diethylpyrocarbonate-based Covalent Labeling and Mass Spectrometric Detection

    Science.gov (United States)

    Zhou, Yuping; Vachet, Richard W.

    2012-04-01

    Covalent labeling and mass spectrometry are seeing increased use together as a way to obtain insight into the 3-dimensional structure of proteins and protein complexes. Several amino acid specific (e.g., diethylpyrocarbonate) and non-specific (e.g., hydroxyl radicals) labeling reagents are available for this purpose. Diethylpyrocarbonate (DEPC) is a promising labeling reagent because it can potentially probe up to 30% of the residues in the average protein and gives only one reaction product, thereby facilitating mass spectrometric analysis. It was recently reported, though, that DEPC modifications are labile for some amino acids. Here, we show that label loss is more significant and widespread than previously thought, especially for Ser, Thr, Tyr, and His residues, when relatively long protein digestion times are used. Such label loss ultimately decreases the amount of protein structural information that is obtainable with this reagent. We find, however, that the number of DEPC modified residues and, thus, protein structural information, can be significantly increased by decreasing the time between the covalent labeling reaction and the mass spectrometric analysis. This is most effectively accomplished using short (e.g., 2 h) proteolytic digestions with enzymes such as immobilized chymotrypsin or Glu-C rather than using methods (e.g., microwave or ultrasonic irradiation) that accelerate proteolysis in other ways. Using short digestion times, we show that the percentage of solvent accessible residues that can be modified by DEPC increases from 44% to 67% for cytochrome c, 35% to 81% for myoglobin, and 76% to 95% for β-2-microglobulin. In effect, these increased numbers of modified residues improve the protein structural resolution available from this covalent labeling method. Compared with typical overnight digestion conditions, the short digestion times decrease the average distance between modified residues from 11 to 7 Å for myoglobin, 13 to 10 Å for

  10. Development of a semiconductor counter telescope with low background for the investigations of charged particles produced in reactions induced by neutrons; Realisation et mise au point d'un telescope a semi-conducteurs et a faible bruit-de-fond pour l'etude des reactions neutronsparticules chargees

    Energy Technology Data Exchange (ETDEWEB)

    Helleboid, J M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1967-08-15

    A AE-E counter telescope for charged particles (p, d, t) produced in reactions with neutrons has been constructed. The semiconductor counter telescope method allows the investigations of two and three-body reactions {sup 6}Li(n,p), D(n,np)n induced by 14 MeV neutrons. By using a coincidence of associated alpha particle pulses with those ({delta}E,E) in the telescope, the background is considerably reduced for all angles outside the coincidence cone, i.e. larger than 15 deg. (L). For forward angles, the same telescope ({delta}E{sub 2}/E) plus a thin semiconductor ({delta}E{sub 1}) allows keeping a low background. The multiparameter analysing method ({delta}E{sub 1}, {delta}E{sub 2}, E) from the experimental range-energy data gives a linearity, an efficiency and an identifying power which are satisfactory. The identification is performed by differed time on a IBM 7044 computer. (author) [French] On a realise un spectrometre de particules chargees (p, d, t) avec identification des particules, pour l'etude des reactions neutrons-particules chargees. La methode du telescope a semi-conducteurs permet d'effectuer l'etude de reactions a deux corps [{sup 6}Li(n,p)] et de reactions a trois corps [D(n,pn)n] a 14 MeV. L'utilisation de la particule alpha associee en coincidence avec les impulsions ({delta}E,E) du telescope permet d'obtenir un bruit-de-fond tres faible pour tous les angles situes en dehors du cone de coincidence, c'est-a-dire superieurs a {approx_equal} 15 deg. (L). Pour les angles avant, le meme telescope ({delta}E{sub 2}/E) plus un semi-conducteur mince ({delta}E{sub 1}) permet de conserver un faible bruit-de-fond. La methode d'analyse multiparametrique ({delta}E{sub 1}, {delta}E{sub 2}, E) a partir des donnees experimentales parcours-energie, donne une linearite, une efficacite et un pouvoir d'identification satisfaisants. L'identification est effectuee en temps differe sur un calculateur numerique IBM 7044. (auteur)

  11. Lead Isotopic Composition in Biogenic Certified Reference Materials Determined by Different ICP-based Mass Spectrometric Techniques

    Czech Academy of Sciences Publication Activity Database

    Ďurišová, Jana; Ackerman, Lukáš; Strnad, L.; Chrastný, V.; Borovička, Jan

    2015-01-01

    Roč. 39, č. 2 (2015), s. 209-220 ISSN 1639-4488 Institutional support: RVO:67985831 Keywords : Pb isotopes * 206 Pb/ 207 Pb * 208 Pb/ 206 Pb * ICP-MS * certified reference materials * vegetation Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.885, year: 2015

  12. Lead Isotopic Composition in Biogenic Certified Reference Materials Determined by Different ICP-based Mass Spectrometric Techniques

    Czech Academy of Sciences Publication Activity Database

    Ďurišová, J.; Ackerman, L.; Strnad, L.; Chrastný, V.; Borovička, Jan

    2015-01-01

    Roč. 39, č. 2 (2015), s. 209-220 ISSN 1639-4488 R&D Projects: GA ČR(CZ) GAP504/11/0484 Institutional support: RVO:61389005 Keywords : Pb isotopes * Pb-206 * Pb-207 * Pb-208 * ICP-MS * certified reference materials * vegetation Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.885, year: 2015

  13. A mass spectrometric study of K39/K41 abundance variations by dual collection and digital measurement technique

    International Nuclear Information System (INIS)

    Bhattacharjee, P.K.; Venkatasubramanian, V.S.

    1977-01-01

    The status of K 39 /K 41 abundance ratios in rocks and minerals is reviewed and the errors and corrections required in such measurements pointed out. A double-collector mass spectrometer with digital recording has been used for K 39 /K 41 measurements in a number of granites, charnockites and zeolites. While the granites do not reveal fractionation effect, K 39 deficiency has been observed in charnockites and zeolites. Possible reasons for such a fractionation are pointed out. (author)

  14. Mass spectrometric method for the determination of the stable isotopic content of nitrous oxide by the technique of direct injection

    International Nuclear Information System (INIS)

    Rahn, T.; Wahlen, M.

    2002-01-01

    A method for the direct isotopic analysis of N 2 O has been developed for VG-Prism H dynamic dual inlet stable isotope mass spectrometer. Tests have shown extreme sensitivity to contamination by carbon dioxide with a dependence of 6.8 per mille per % CO 2 for δ 15 N and 12.4 per mille per % CO 2 for δ 18 O. Trace amounts of CO 2 have proven difficult to eliminate, particularly for small sample sizes. In order to ensure accurate analyses an indicator of CO 2 contamination must be monitored and corrections applied when necessary. We have found that ions with mass to charge ratios of 12 and 22 are excellent proxies for CO 2 contamination. Empirical relationships between these indicator species and CO 2 contamination are documented which allow for corrections to be applied to raw data. Additional corrections required due to the presence of isobaric molecules containing 17 O are described. Issues of standardization are discussed and sample handling procedures described. Finally, these methods and corrections are applied to a suite of stratospheric air samples. (author)

  15. Experimental study of superconductivity induced by proximity effects; Etude experimentale de la supraconductivite induite par effets de proximite

    Energy Technology Data Exchange (ETDEWEB)

    Martinet, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-11-15

    We present a study of the proximity effects between a superconductor (InBi or PbBi alloys) and a 'normal' metal (Zn or Sn respectively, above their critical temperature) using essentially the tunneling techniques. On the N side, some specific properties of such an induced superconductivity are described: linear variation of the pair potential near the critical temperature of the binary layer, T{sub CNS}; reduced energy scale at T{sub CNS}; evidence of a thermodynamic critical field (called breakdown field) presented by N above its critical temperature. On the S side, we study crossing from a gapless to a quasi gapless regime. This gives a proof of a finite coherence length at T{sub CNS}. Experimental details (in particular about the preparation and measurement of tunneling junctions) are given in annexe. Possible applications are suggested. (author) [French] Nous presentons une etude experimentale des effets de proximite entre un supraconducteur (alliages d'InBi ou de PbBi) et un metal 'normal' (Zn ou Sn respectivement, pris au-dessus de leur temperature critique), en utilisant principalement des mesures d'effet tunnel. Du cote N, on met en evidence des proprietes specifiques de cette supraconductivite induite: comportement lineaire du potentiel de paires pres de la temperature critique du bilame, T{sub CNS}; echelle d'energie reduite a T{sub CNS}; apparition d'un champ critique thermodynamique (appele champ de basculement) dans N au-dessus de sa temperature critique. Du cote S, nous etudions le passage continu d'une situation 'sans bande interdite' a basse temperature et en champ fort, a une situation 'pratiquement sans bande interdite' pres de T{sub CNS} en champ nul. Ceci fournit une preuve de la non divergence de la longueur de coherence a T{sub CNS}. Les techniques experimentales (et en particulier la preparation et la mesure de jonctions tunnel) sont decrites en detail dans une annexe. On envisage des applications pratiques possibles. (auteur)

  16. Study of the molecular structure of uranium hexafluoride; Contribution a l'etude de la structure moleculaire de l'hexafluorure d'uranium

    Energy Technology Data Exchange (ETDEWEB)

    Bougon, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-06-01

    The vibrational spectrum of uranium hexafluoride has been studied in both the gaseous and solid states. The study of gaseous UF{sub 6} confirms the regular octahedral structure of the fluorine atoms around the central U atom and makes it possible to evaluate some of the vibrational frequencies. From these, some new force constants have been determined. A tetragonal distortion is observed on solid UF{sub 6}; this distortion has only observed up till now by means of X-ray diffraction and nuclear magnetic resonance techniques. (author) [French] Le spectre de vibration de l'hexafluorure d'uranium UF{sub 6} est etudie sous les formes gazeuse et solide. L'etude de l'UF{sub 6} gaz confirme la structure d'octaedre regulier d'atomes de fluor autour de l'atome central d'uranium et apporte une precision sur certaines frequences de vibration. A partir de ces valeurs, de nouvelles determinations de constantes de force ont ete realisees. L'observation de UF{sub 6} solide confirme la deformation tetragonale de l'octaedre, deformation observee jusqu'a present par les seules methodes de resonance magnetique nucleaire et diffraction des rayons X. (auteur)

  17. Reply to "On Vaporization of liquid Pb-Li eutectic alloy from 1000 K to 1200 K- A high temperature mass spectrometric study"

    Science.gov (United States)

    Jain, Uttam; Mukherjee, Abhishek

    2018-03-01

    This communication is in response to a letter to editor commenting on the authors' earlier paper "Vaporization of liquid Pb-Li eutectic alloy from 1000 K to 1200 K - A high temperature mass spectrometric study".

  18. A laser photofragmentation time-of-flight mass spectrometric study of acetophenone at 193 and 248 nm

    Science.gov (United States)

    Zhao, H.-Q.; Cheung, Y.-S.; Liao, C.-L.; Liao, C.-X.; Ng, C. Y.; Li, Wai-Kee

    1997-11-01

    The photodissociation of acetophenone (C6H5COCH3) at 193 and 248 nm has been studied using the time-of-flight mass spectrometric technique. For hν=193 nm, two major primary channels, C6H5COCH3+hν→C6H5CO+CH3 [channel (1)] and C6H5+CH3CO [channel (2)], are observed with comparable cross sections. Data analysis shows that ≈30%-50% of primary C6H5CO and CH3CO radicals further decomposes, yielding secondary products C6H5+CO and CH3+CO, respectively. The translational energy release measurements indicate that for both channels (1) and (2) at 193 nm, ≈25%-30% of the available energy is channeled into kinetic energies of the primary photofragments. Measurements at hν=248 nm reveal that the branching ratio of channel (2) to channel (1) is ≈0.01. For channel (1) at hν=248 nm, ≈42% of the available energy is directed as the kinetic energy of the photofragments. The observed maximum kinetic energy release for channel (1) at 248 nm yields a value of 85.0±2.2 kcal/mol for the C6H5CO-CH3 bond dissociation energy at 0 K (D0). The photofragment angular distributions are found to be isotropic for both channels (1) and (2) at hν=193 nm and for channel (1) at hν=248 nm. A minor photodissociation channel C6H5COCH3+hν→C6H5CH3+CO is identified at both hν=193 and 248 nm. The energetics for the dissociation reactions of acetophenone have also been investigated using ab initio Gaussian-2-type procedures. The heats of formation at 0 K (ΔfH°0) for C6H5CO and C6H5 calculated using the isodesmic reaction scheme are 33.9±1.3 and 87.6±1.0 kcal/mol, respectively. These results suggest that the literature ΔfH°0 values for C6H5CO and C6H5 are likely to be low by 3-4 kcal/mol. These theoretical ΔfH° values for C6H5CO and C6H5 yield a theoretical D0(C6H5CO-CH3) value of 85.1±1.4 kcal/mol, which is in excellent accord with the experimental results obtained in the present study.

  19. Contribution a l'etude des determinants socioculturels et ...

    African Journals Online (AJOL)

    ... a consisté à l'élaboration des outils de collecte et son administration par les techniques variées ... Les résultats obtenus montrent que les facteurs explicatifs de la ... Thus, within the framework of this research, the comparative analysis of the ...

  20. Novel concepts and strategies in anticancer metallodrug development : towards oral activity, peptide conjugation and mass spectrometric applications

    Energy Technology Data Exchange (ETDEWEB)

    Meier, S.

    2013-07-01

    including top-down electrospray ionization-mass spectrometry (ESI-MS). Mass spectrometry is an invaluable tool in the analysis of molecular interactions between metallodrugs and biomolecules, such as DNA or proteins and their constituents. Furthermore, the molecular reactivity may give insight into the mode of action of a particular metallodrug or family of metallodrugs. Within the frame of this Ph.D. thesis, mass spectrometric techniques have been used to characterize the reactivity of representative (thio)pyr(id)onato RuII–p-cymene metallodrugs towards amino acids, nucleotides and proteins and an inverse correlation was found between extent of protein binding and antiproliferative activity, at least for these families of metallodrugs. Furthermore, the analysis of metallation sites of metallodrugs on proteins by mass spectrometric methods poses significant challenges in many cases due to low adduct detection efficiencies. Top-down mass spectrometric analysis is a promising approach to determine oxaliplatin binding sites on ubiquitin and different fragmentation techniques were investigated with the combination of higher energy C-trap dissociation (HCD) and electron transfer dissociation (ETD) tandem mass spectrometry yielding the highest information content. This approach led to the confirmation of methionine-1 as the primary and histidine-68 as the secondary binding site. (author) [German] Manche auf Ruthenium und Osmium als Zentralatomen basierende Koordinationsverbindungen haben sich als vielversprechende tumorhemmende Wirkstoffkandidaten erwiesen. Derzeit stellen organometallische RuII und OsII Komplexverbindungen—durch einen η6-koordinierenden Arenliganden stabilisiert—die bis dato modernste Forschungsstrategie dar, um solche Wirkstoffe zu erhalten. Im Rahmen dieser Dissertation wurden neuartige, tumorhemmende RuII– und OsII–Aren Verbindungen entdeckt und in Bezug auf ihre molekularen Wechselwirkungen mit Biomolekülen untersucht. Letzteres wurde vorab

  1. Standard test methods for chemical and mass spectrometric analysis of nuclear-grade gadolinium oxide (Gd2O3) powder

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 These test methods cover procedures for the chemical and mass spectrometric analysis of nuclear-grade gadolinium oxide powders to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Carbon by Direct CombustionThermal Conductivity C1408 Test Method for Carbon (Total) in Uranium Oxide Powders and Pellets By Direct Combustion-Infrared Detection Method Total Chlorine and Fluorine by Pyrohydrolysis Ion Selective Electrode C1502 Test Method for Determination of Total Chlorine and Fluorine in Uranium Dioxide and Gadolinium Oxide Loss of Weight on Ignition 7-13 Sulfur by CombustionIodometric Titration Impurity Elements by a Spark-Source Mass Spectrographic C761 Test Methods for Chemical, Mass Spectrometric, Spectrochemical,Nuclear, and Radiochemical Analysis of Uranium Hexafluoride C1287 Test Method for Determination of Impurities In Uranium Dioxide By Inductively Coupled Plasma Mass Spectrometry Gadolinium Content in Gadolinium Oxid...

  2. Comparison of accelerator mass spectrometric measurement with liquid scintillation counting measurement for the determination of 14C in environmental samples

    International Nuclear Information System (INIS)

    Yasuike, Kaeko; Yamada, Yoshimune; Amano, Hikaru

    2010-01-01

    The concentrations of organically-bound 14 C in tree-ring cellulose of a Japanese Black Pine grown in Shika-machi (37.0 deg. N, 136.8 deg. E) and those of a Japanese Cedar grown in Kanazawa (36.5 deg. N, 136.7 deg. E), Japan, were analyzed for the ring-years from 1989 to 1998 by the accelerator mass spectrometric measurement. The results were compared with those of the same samples analyzed by the liquid scintillation counting measurement to determine the reliability of liquid scintillation counting measurement. An important result of this study is that the sensitivity and reproducibility of accelerator mass spectrometric measurement was almost equal to that of liquid scintillation counting measurement.

  3. Measurement of fission yields for 232-Th (n,f) at 14,7 MeV by direct gamma spectrometric method

    International Nuclear Information System (INIS)

    Chouak, K.; Berrada, M.; Embarech, K.

    1994-01-01

    Fission yields for the reaction 232-Th (n,f) were measured at 14,7 MeV using the activation technique with direct gamma spectrometric method. Neutrons were produced via the T(d,n) sup 4 He reaction. The neutron fluences were determined relative to the well-known sup 2 sup 7 Al(n,p) sup 2 sup 7 Mg or sup 2 sup 7 Al(n,alpha) sup 2 sup 4 Na cross section, according to the irradiation time. Yields of fission products were determined by measuring the induced gamma ray activities of the irradiated Th foils, using a calibrated Ge(Li) detector. All necessary corrections were taken into account: self absorption, coincidence losses and natural gamma rays. Fifty six cumulative yields were measured and only twenty one corresponding results were found in the literature (Crouch,1977). A satisfactory agreement is observed between our results and the published data with the exception of the masses:A=134 and A=140. 1 tab., 2 refs. (author)

  4. Graphene oxide membrane as an efficient extraction and ionization substrate for spray-mass spectrometric analysis of malachite green and its metabolite in fish samples.

    Science.gov (United States)

    Wei, Shih-Chun; Fan, Shen; Lien, Chia-Wen; Unnikrishnan, Binesh; Wang, Yi-Sheng; Chu, Han-Wei; Huang, Chih-Ching; Hsu, Pang-Hung; Chang, Huan-Tsung

    2018-03-20

    A graphene oxide (GO) nanosheet-modified N + -nylon membrane (GOM) has been prepared and used as an extraction and spray-ionization substrate for robust mass spectrometric detection of malachite green (MG), a highly toxic disinfectant in liquid samples and fish meat. The GOM is prepared by self-deposition of GO thin film onto an N + -nylon membrane, which has been used for efficient extraction of MG in aquaculture water samples or homogenized fish meat samples. Having a dissociation constant of 2.17 × 10 -9  M -1 , the GOM allows extraction of approximately 98% of 100 nM MG. Coupling of the GOM-spray with an ion-trap mass spectrometer allows quantitation of MG in aquaculture freshwater and seawater samples down to nanomolar levels. Furthermore, the system possesses high selectivity and sensitivity for the quantitation of MG and its metabolite (leucomalachite green) in fish meat samples. With easy extraction and efficient spray ionization properties of GOM, this membrane spray-mass spectrometry technique is relatively simple and fast in comparison to the traditional LC-MS/MS methods for the quantitation of MG and its metabolite in aquaculture products. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Barley husk carbon as the fiber coating for the solid-phase microextraction of twelve pesticides in vegetables prior to gas chromatography-mass spectrometric detection.

    Science.gov (United States)

    Liang, Weiqian; Wang, Juntao; Zang, Xiaohuan; Dong, Wenhuan; Wang, Chun; Wang, Zhi

    2017-03-31

    In this work, a barley husk biomaterial was successfully carbonized by hydrothermal method. The carbon had a high specific surface area and good stability. It was coated onto a stainless steel wire through sol-gel technique to prepare a solid-phase microextraction fiber for the extraction of trace levels of twelve pesticides (tsumacide, fenobucarb, indoxacarb, diethofencarb, thimet, terbufos, malathion, thiamethoxam, imidacloprid, buprofezin, acetamiprid, thiamethoxam) from vegetable samples prior to gas chromatography-mass spectrometric (GC-MS) detection. The main experimental parameters that could influence the extraction efficiency such as extraction time, extraction temperature, sample pH, sample salinity, stirring rate, desorption temperature and desorption time, were investigated. Under the optimized conditions, the linearity was observed in the range of 0.2-75.0μgkg -1 for tomato samples, and 0.3-60.0μgkg -1 for cucumber samples, with the correlation coefficients (r) ranging from 0.9959 to 0.9983. The limits of detection of the method were 0.01-0.05μgkg -1 for tomato samples, and 0.03-0.10μgkg -1 for cucumber samples. The recoveries of the analytes for the method from spiked samples were in the range of 76%-104%, and the precision, expressed as the relative standard deviations, was less than 12%. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements.

    Science.gov (United States)

    Xu, Yihong; Qiao, Jixin; Hou, Xiaolin; Pan, Shaoming; Roos, Per

    2014-02-01

    This paper reports an analytical method for the determination of plutonium isotopes ((238)Pu, (239)Pu, (240)Pu, (241)Pu) in environmental samples using anion exchange chromatography in combination with extraction chromatography for chemical separation of Pu. Both radiometric methods (liquid scintillation counting and alpha spectrometry) and inductively coupled plasma mass spectrometry (ICP-MS) were applied for the measurement of plutonium isotopes. The decontamination factors for uranium were significantly improved up to 7.5 × 10(5) for 20 g soil compared to the level reported in the literature, this is critical for the measurement of plutonium isotopes using mass spectrometric technique. Although the chemical yield of Pu in the entire procedure is about 55%, the analytical results of IAEA soil 6 and IAEA-367 in this work are in a good agreement with the values reported in the literature or reference values, revealing that the developed method for plutonium determination in environmental samples is reliable. The measurement results of (239+240)Pu by alpha spectrometry agreed very well with the sum of (239)Pu and (240)Pu measured by ICP-MS. ICP-MS can not only measure (239)Pu and (240)Pu separately but also (241)Pu. However, it is impossible to measure (238)Pu using ICP-MS in environmental samples even a decontamination factor as high as 10(6) for uranium was obtained by chemical separation. © 2013 Elsevier B.V. All rights reserved.

  7. Quantitative analysis of sodium di-uranate for Al, Ca, Fe, Mg, Mn, Na by flame-atomic absorption spectrometric method

    International Nuclear Information System (INIS)

    Jat, J.R.; Balaji Rao, Y.; Subba Rao, Y.

    2015-01-01

    Nuclear Fuel Complex (NFC) receives Sodium Di-Uranate (SDU) from Uranium Corporation of India Limited (UCIL) for producing sinterable UO 2 pellets for manufacturing fuel sub assemblies. Several impurities present in ore find their way into SDU during its conversion. Stringent specification have been laid down by the reactor designs for achieving the optimum performance of the fuel and several impurity element like Al, Ca, Fe, Mg, Mn, Na among others affects severely performance of UO 2 fuel. Most of the impurity including the above mentioned elements are generally analysed by ICP-OES method. However, determination of Al, Ca, Fe, Mg, Mn and Na by ICP-OES requires lot of dilution as they are present at high levels in SDU. Apart from introducing dilution error, dilution process is very tedious and time consuming work and not a preferred choice in an industrial lab like control lab where large analytical load exists and time bound analysis is a requirement. To avoid these difficulties a simple and reliable Flame Atomic absorption spectrometric technique has been developed for regular analysis. Present method involves dissolution of SDU sample in Conc. HNO 3 and after the complete dissolution the sample solution has been evaporated to near dryness on a hot plate. Subsequently sample solution has been brought into 4N HNO 3 medium

  8. Identification of Polish cochineal (Porphyrophora polonica L.) in historical textiles by high-performance liquid chromatography coupled with spectrophotometric and tandem mass spectrometric detection.

    Science.gov (United States)

    Lech, Katarzyna; Jarosz, Maciej

    2016-05-01

    The present work reports a method for identification of Polish cochineal (Porphyrophora polonica L.) in historical fabrics by the use of high-performance liquid chromatography coupled with diode array and tandem mass spectrometric detection with electrospray ionization (HPLC-DAD-ESI MS/MS). This hyphened technique allows detection and identification of 16 new minor colorants present in the discussed scale insect (including two previously observed by Wouters and Verhecken (Ann Soc Entomol Fr. 1989;25:393-410), but specified only as compounds of unknown structures) that do not occur (e.g., in American cochineal). The MS/MS experiments, complemented with UV-VIS data, enable identification of mono- and di-, C- and O-hexosides of kermesic and flavokermesic acids or their derivatives. The present paper introduces a fingerprint of color compounds present in Polish cochineal and defines them, particularly pp6 (ppI, O-hexoside of flavokermesic acid), as its markers allow distinguishing of Polish-cochineal reds from the American ones. Usefulness of the selected set of markers for identification of Polish cochineal has been demonstrated in the examination of textiles from the collection of the National Museum in Warsaw using the multiple reaction monitoring (MRM) method, originally elaborated on the basis of this study.

  9. Geologic-radiometric techniques applied for uranium prospection at the Hierro-Cayo Largo area

    International Nuclear Information System (INIS)

    Gongora, L.E.; Olivera, J.

    1995-01-01

    Using geologic-radiometric techniques uraniferous anomalies were evaluated at the Hierro-Cayo Largo area located in Pinar del Rio province. During the uranium prospection works at most promising areas, geologic itineraries and gamma ray, radon emanation spectrometric survey were done. Trenches were made and some boreholes were drilled (up to 20-30 m depth). In addition a lot of samples were taken in order to determine the amount of U, Ra, Th, y K by spectrometric techniques. As result of this investigation, a geological placing, a mineralogical and geochemical characteristic of uraniferous mineralization was possible to find out. The appropriate prospection indications for uranium exploration at Esperanza geologic zone were defined

  10. The gas-chromatographic and gas-chromatographic-mass-spectrometric identification of halogen-containing organic compounds

    Science.gov (United States)

    Gidaspov, B. V.; Zenkevich, I. G.; Rodin, A. A.

    1989-09-01

    The problem of identifying halogen-containing organic compounds in their gas-chromatographic and gas-chromatographic-mass-spectrometric (GC-MS) determination in different materials has been examined. Particular attention has been paid not to the complete characterisation of methods for carrying out this analysis but to the most important problem of increasing the selectivity at the stages of sampling, separation, and interpretation of the gas-chromatographic and GC-MS information. The bibliography contains 292 references.

  11. Topic model-based mass spectrometric data analysis in cancer biomarker discovery studies.

    Science.gov (United States)

    Wang, Minkun; Tsai, Tsung-Heng; Di Poto, Cristina; Ferrarini, Alessia; Yu, Guoqiang; Ressom, Habtom W

    2016-08-18

    A fundamental challenge in quantitation of biomolecules for cancer biomarker discovery is owing to the heterogeneous nature of human biospecimens. Although this issue has been a subject of discussion in cancer genomic studies, it has not yet been rigorously investigated in mass spectrometry based proteomic and metabolomic studies. Purification of mass spectometric data is highly desired prior to subsequent analysis, e.g., quantitative comparison of the abundance of biomolecules in biological samples. We investigated topic models to computationally analyze mass spectrometric data considering both integrated peak intensities and scan-level features, i.e., extracted ion chromatograms (EICs). Probabilistic generative models enable flexible representation in data structure and infer sample-specific pure resources. Scan-level modeling helps alleviate information loss during data preprocessing. We evaluated the capability of the proposed models in capturing mixture proportions of contaminants and cancer profiles on LC-MS based serum proteomic and GC-MS based tissue metabolomic datasets acquired from patients with hepatocellular carcinoma (HCC) and liver cirrhosis as well as synthetic data we generated based on the serum proteomic data. The results we obtained by analysis of the synthetic data demonstrated that both intensity-level and scan-level purification models can accurately infer the mixture proportions and the underlying true cancerous sources with small average error ratios (data, we found more proteins and metabolites with significant changes between HCC cases and cirrhotic controls. Candidate biomarkers selected after purification yielded biologically meaningful pathway analysis results and improved disease discrimination power in terms of the area under ROC curve compared to the results found prior to purification. We investigated topic model-based inference methods to computationally address the heterogeneity issue in samples analyzed by LC/GC-MS. We observed

  12. Generalities on the dynamic behaviour of rapid reactors. Preliminary studies on Rapsodie; Generalites sur le comportement dynamique des piles rapides. Etudes preliminaires de rapsodie

    Energy Technology Data Exchange (ETDEWEB)

    Campan, J L; Chaumont, J P; Clauzon, P P; Ghesquiere, G; Leduc, J; Schmitt, A P; Zaleski, C P [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1963-07-01

    The study of the dynamic behaviour of fast reactors may be divided into three section: 1. Stability studies around equilibrium power only the linear case was examining. S. Transient studies in the case of usual reactor operation (shut down, scram, etc.) with thermal shocks evaluation, for instance. 3. Explosion studies, for the maximum credible accidents. This report presents the status of the studies performed at the 'Physics Research Department' at Cadarache. Methods used are detailed and illustrated with the results obtained on a preliminary metallic core of the Rapsodie Reactor. (authors) [French] Le comportement dynamique des piles rapides, se presente tout naturellement sous trois aspects: 1. Etude de stabilite autour d'un regime d'equilibre (nous nous sommes bornes ici au cas lineaire). 2. Etude de regimes transitoires lors des operations normales de pile (arret, arret d'urgence, etc.) avec evaluation des chocs thermiques par exemple. 3. Etude des regimes transitoires de caractere explosif lors des accidents les plus graves possibles. Ce rapport presente l'etat des etudes a la date du 20 decembre 1961 a la Section d'Etudes de Piles Rapides a CADARACHE. Les methodes employees ont ete detaillees et illustrees a partir des resultats obtenus sur une premiere version 'combustible metallique' de Rapsodie. (auteurs)

  13. Etude cinétique de la dégradation de l'Endosufane en solution ...

    African Journals Online (AJOL)

    Etude cinétique de la dégradation de l'Endosufane en solution. S Traore, K Mamadou, A Dembele, V Yao, Y Bekro, P Mazellier, B Legube, P Houenou. Abstract. Les pesticides sont fréquemment utilisés en Côte d'Ivoire. Leur détection dans les eaux de forage témoigne de leur mauvais usage et d'un grave problème ...

  14. Study of the tributyl phosphate - 30% dodecane solvent; Etude du solvant phosphate tributylique - 30 % dodecane

    Energy Technology Data Exchange (ETDEWEB)

    Leroy, P [Commissariat a l' Energie Atomique, Fontenay-aux-Roses. Centre d' Etudes Nucleaires, 92 (France)

    1967-07-01

    This study, originating mainly from a literature survey, gives the principal chemical and physical features of the tributyl-phosphate (TBP) agent diluted at 30 volumes per cent in dodecane. The mixture is a very commonly used extractant in nuclear fuel processing. In this paper, the main following points are reported: -) the components (TBP and diluents) -) the TBP-diluents systems (non-loaded), -) the TBP-diluents-water systems, -) TBP-diluents-water-nitric acid systems, and -) industrial solvents. (author) [French] Cette etude, d'origine bibliographique, regroupe les caracteristiques physico-chimiques essentielles du phosphate tributylique (TBP) dilue a 30% en volume dans du dodecane. Ce melange constitue un agent d'extraction tres utilise dans le traitement des combustibles nucleaires. Les principaux points traites sont les suivants: -) les constituants (TBP et diluants), -) les systemes TBP-diluants non charges, -) les systemes TBP-diluants-eau, -) les systemes TBP-diluants-eau-acide nitrique, et -) les solvants industriels. (auteur)

  15. An economic study of the site of Marcoule; Etude economique du site de Marcoule

    Energy Technology Data Exchange (ETDEWEB)

    Duprat, H [Commissariat a l' Energie Atomique, Marcoule (France). Centre d' Etudes Nucleaires

    1964-07-01

    The study of this site of the Marcoule Center shows that its regional economical influence is limited to the buying power distributed among its personnel. This entails distortions between first this supplementary buying power and the overall markets within the possible Marcoule influence zone, and secondly the concentration on Bagnols-sur-Ceze and this town's normal extension possibilities. (author) [French] L'etude du site de Marcoule demontre que son influence economique se limite, pour la region, au pouvoir d'achat distribue a son personnel. Ceci entraine une disproportion d'une part entre ce pouvoir d'achat supplementaire et l'ensemble des marches contenus dans l'aire d'influence possible de Marcoule, d'autre part entre la concentration realisee a Bagnole-sur-Ceze et la capacite d'extension normale de cette agglomeration. (auteur)

  16. Neutronic study of the two french heavy water reactors; Etude neutronique des deux piles francaises a eau lourde

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    The two french reactors - the reactor of Chatillon, named Zoe, and the reactor of Saclay - P2 - were the object of detailed neutronic studies which the main ideas are exposed in this report. These studies were mostly done by the Department of the Reactor Studies (D.E.P.). We have thus studied the distribution of neutronic fluxes; the factors influencing reactivity; the link between reactivity and divergence with the formula of Nordheim; the mean time life of neutrons; neutron spectra s of P2; the xenon effect; or the effect of the different adjustments of the plates and controls bar. (M.B.) [French] Les deux reacteurs francais - la pile de Chatillon, appelee ZOE, et la pile de Saclay, designee dans la suite par P2 - ont fait l'objet d'etudes neutroniques detaillees dont les principales sont exposees dans ce rapport. Ces etudes ont ete pour la plupart effectuees dans le cadre du Departement des Etudes de Piles (D.E.P.). Nous avons ainsi entre autre etudie la distribution du flux neutronique; les facteurs influencants la reactivite; le lien entre reactivite et divergence par la formule de Nordheim; le temps de vie moyen des neutrons; les spectres de neutrons de P2; l'effet xenon; ou encore l'effet des differents reglages des plaques et barres de controles. (M.B.)

  17. Study of uranium-titanium diffusion; Etude de la diffusion uranium-titane

    Energy Technology Data Exchange (ETDEWEB)

    Adda, Y; Philibert, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Institut de Recherches de la Siderurgie Francaise (IRSID), 78 - Saint-Germain-en-Laye (France)

    1959-07-01

    . (author) [French] Dans le cadre de recherches sur la diffusion chimique de l'uranium et des metaux de transition, nous avons etudie le systeme uranium-titane. Les couples de diffusion sont prepares, suivant une technique que avons deja decrite, par soudage sous pression de plaquettes d'uranium et de titane. Apres traitement de diffusion sous vide, les echantillons sont etudies micrographiquement suivant une section polie. Cet examen nous a permis de mettre en evidence une diffusion intergranulaire au-dessous de 650 deg. C; aux temperatures superieures, la diffusion a lieu uniquement en volume, et la zone de diffusion apparait alors comme une succession de bandes qui se distinguent par leur aspect micrographique. L'etude de la cinetique de croissance de ces bandes nous a permis de mesurer les 'coefficients de penetration' correspondants. En outre, nous avons observe, dans la zone de diffusion, des variations importantes de microdurete, que nous avons cherche a relier a la variation de concentration. Celle-ci est mesuree par analyse ponctuelle au moyen de la microsonde de Castaing. Nous avons ainsi etabli avec precision les courbes concentration-penetration pour des temperatures comprises entre 950 et 1075 deg. C. A partir de ces courbes nous avons calcule le coefficient de diffusion D en fonction de la concentration c par la methode de Matano. La coube D(c) presente a toutes les temperatures une forme en U, deja observee pour le systeme U-Zr. L'energie d'activation passe par un maximum de 42 kcal/g pour une concentration atomique 0,5. Bien que nous n'ayons observe que rarement la presence de pores dans la zone de diffusion, nous avons neanmoins observe un effet Kirkendall important en etudiant les deplacements x{sub i} d'un interface repere au moyen de fils de tungstene. Ces deplacements peuvent s'exprimer en fonction du temps t et de la temperature T par la relation x{sub i} = 0,9 t {sup 1/2} exp ( - 14600/(RT)). Enfin, au moyen des equations de Darken nous avons calcule

  18. Determination of plutonium isotopes (238Pu, 239Pu, 240Pu, 241Pu) in environmental samples using radiochemical separation combined with radiometric and mass spectrometric measurements

    DEFF Research Database (Denmark)

    Xu, Yihong; Qiao, Jixin; Hou, Xiaolin

    2014-01-01

    counting and alpha spectrometry) and inductively coupled plasma mass spectrometry (ICP-MS) were applied for the measurement of plutonium isotopes. The decontamination factors for uranium were significantly improved up to 7.5×105 for 20 g soil compared to the level reported in the literature......, this is critical for the measurement of plutonium isotopes using mass spectrometric technique. Although the chemical yield of Pu in the entire procedure is about 55%, the analytical results of IAEA soil 6 and IAEA-367 in this work are in a good agreement with the values reported in the literature or reference......Pu. However, it is impossible to measure 238Pu using ICP-MS in environmental samples even a decontamination factor as high as 106 for uranium was obtained by chemical separation....

  19. An overview on the study of quark gluon plasma with Alice dimuon spectrometer; Apercu sur l'etude du plasma de Quarks et de gluons a l'aide du spectrometre dimuons d'Alice

    Energy Technology Data Exchange (ETDEWEB)

    Espagnon, B

    2007-10-15

    The Alice experiment is one of the four main LHC (Large Hadron Collider) experiments. It is dedicated to the study of a new state of matter: the quark gluon plasma, where quarks and gluons are no longer confined within hadrons. In this document, the physics issues that led to the construction of Alice dimuon spectrometer, are described. Then, the research and development on the dimuon spectrometer is presented. The different absorbers are described and experimental tests used to determine their dimensions are presented. The dimuon trigger built using the RPC (Resistive Plate Chamber) streamer mode is then described along with the associated beam and cosmic tests and results. Finally, the tracking system is described in detail and more particularly all its electronics and the first station. The physics constraints on the expected performances of all these systems are clearly defined. (author)

  20. Study of the electron-positron annihilation in the galactic center region with the Integral/SPI spectrometer; Etude de l'annihilation electron-positon dans la region du centre galactique avec le spectrometre INTEGRAL/SPI

    Energy Technology Data Exchange (ETDEWEB)

    Sizun, P

    2007-04-15

    A spectral feature was detected in 1970 in the gamma-ray emission from the central regions of the Milky Way, during balloon flight observations. Located near 511 keV, this feature was soon attributed to the gamma-ray line tracing the annihilation of electrons with their anti-particles, positrons. However, none of the multiple astrophysical scenarios contemplated to explain the production of positrons in the Galactic bulge has been able to reproduce the high injection rate deduced from the flux of the 511 keV line, close to 10{sup 43} positrons per second. Launched in 2002, the European gamma-ray satellite INTEGRAL was provided with a spectrometer, SPI, whose unprecedented imaging and spectral capabilities in this energy range enable us to further study the source of the 511 keV line detected in the Galactic centre region. Indeed, a better determination of the spatial extent of the source, the intrinsic width of the line and the fraction of positrons annihilating in-flight, directly or via the formation of ortho-Positronium atoms would improve our knowledge of both the annihilation medium and the initial source of positrons, and could allow us to discriminate between the various explanatory scenarios. The first part of this thesis deals with a key ingredient in the extraction of the annihilation spectrum: the optimization of the instrumental background model. New data screening and tracer selection procedures are presented. Classical multi-linear models are compared to neural and Bayesian networks. Finally, three years of observation are used to constrain the width of the source and derive its spectrum. The second part of the thesis focuses on one of the possible scenarios explaining the high positron injection rate deduced from the flux of the 511 keV line: the annihilation of light dark matter particles into electron-positron pairs. The various radiation mechanisms involved are modeled and confronted to observations in order to set an upper limit on the injection energy of positrons - e.g. on the mass of the light dark matter particle - found to vary between 3 and 7.5 MeV, depending on the degree of ionization of the interstellar medium. (author)

  1. Study of jet production in diffraction at HERA with the VFPS; Etude de la production de jets en diffraction a HERA, a l'aide du spectrometre a protons VFPS

    Energy Technology Data Exchange (ETDEWEB)

    Delvax, Julie

    2010-11-15

    In this thesis the experimental study of the process ep{yields}e{sup '}pX+n jets (N{>=}2) at {radical}(s)=319 GeV is described. Presented are distributions of E, y, p{sub t}, {theta}{sub j1}, {phi}{sub j1}, and {theta}{sub j1}-{theta}{sub j2}, {phi}{sub j1}-{phi}{sub j2}, and M{sub j1j2} for n=2, as well as the total cross section. (HSI)

  2. Study of dimuon spectrometer tracking chambers of the ALICE experiment at LHC; Etude des chambres de trajectoire du spectrometre dimuons de l'experience ALICE aupres du LHC

    Energy Technology Data Exchange (ETDEWEB)

    Kharmandarian, Liliane [Institut de Physique Nucleaire, CNRS - IN2P3, Universite Paris - Sud, 91406 Orsay Cedex (France)

    1999-12-16

    The ALICE (A Large Ion Collider Experiment) experiment will study ultrarelativistic heavy ion collisions at the Large Hadron Collider (LHC) in CERN as of 2005. An extensive R and D programme has been carried out on the dimuon spectrometer tracking chambers at the Nuclear Physics Institute in Orsay. Three multiwire proportional chamber prototypes with segmented cathodes, including a full-scale 1 m{sup 2} version, were constructed. In this thesis, the experimental tests are presented along with the simulations used to understand and optimize the detectors' performances. The prototypes were tested several times at the PS and SPS accelerators. The aims were to validate the choices made in terms of mechanical construction, geometrical parameters, gas mixture and read-out electronics. Analysis of the large amount of data collected has shown that the performances of this type of detector fulfill the required specifications. The results concerning the detectors' characteristics, spatial resolution efficiency, gain and homogeneity are given. Spatial resolutions of less than thirty microns were obtained. In parallel with the in-beam tests, several simulations have been developed in order to gain a better understanding of the detectors' response. They allowed, in particular, to define the segmentation of the cathode plane, to study the position reconstruction algorithm and to establish the future electronics specifications. (author)

  3. Determination of deuterium in metal by vacuum fusion-mass spectrometric method

    International Nuclear Information System (INIS)

    Wada, Yukio; Akiyama, Shigeo; Ochiai, Ken-ichi; Asakura, Toshiro; Tsutsumi, Ken-ichi

    1976-01-01

    A specimen of deuterium-enriched Zircaloy was prepared to study a method for the determination of deuterium in metal. The measuring apparatus consists of vacuum fusion section (10 -5 -10 -4 Torr), gas extracting and collecting section, the section of introducing both standard D 2 and HD gases into a gas holder, and mass spectrometric analysis section. The deuterium in Zircaloy can be extracted by 100% for 5 min. at 1600 0 C. The main components of the extracted gas are H 2 , D 2 , HD, CO, H 2 O and N 2 . Deuterium is determined by the calculation from the determinations of D 2 and HD. The amounts of D 2 and HD gases in the specimen were obtained from the calibration curve prepared and the spectrum intensity of D 2 + and HD + resulted from specimen analysis. As a result of the analysis of D 2 -enriched Zircaloy, it has been found that the precision of the determination is within the coefficient variation of about 3% for the extracted D 2 gas amount of 10 -3 -10 -2 ml (STP), including the deuterium segregation in the specimen, and the determination limit was 1 x 10 -5 ml (STP). (Kobatake, H.)

  4. Targeted selected reaction monitoring mass spectrometric immunoassay for insulin-like growth factor 1.

    Directory of Open Access Journals (Sweden)

    Eric E Niederkofler

    Full Text Available Insulin-like growth factor 1 (IGF1 is an important biomarker of human growth disorders that is routinely analyzed in clinical laboratories. Mass spectrometry-based workflows offer a viable alternative to standard IGF1 immunoassays, which utilize various pre-analytical preparation strategies. In this work we developed an assay that incorporates a novel sample preparation method for dissociating IGF1 from its binding proteins. The workflow also includes an immunoaffinity step using antibody-derivatized pipette tips, followed by elution, trypsin digestion, and LC-MS/MS separation and detection of the signature peptides in a selected reaction monitoring (SRM mode. The resulting quantitative mass spectrometric immunoassay (MSIA exhibited good linearity in the range of 1 to 1,500 ng/mL IGF1, intra- and inter-assay precision with CVs of less than 10%, and lowest limits of detection of 1 ng/mL. The linearity and recovery characteristics of the assay were also established, and the new method compared to a commercially available immunoassay using a large cohort of human serum samples. The IGF1 SRM MSIA is well suited for use in clinical laboratories.

  5. A spectrometrical method to measure the deuterium content in 2H-enriched water

    International Nuclear Information System (INIS)

    Dumke, I.

    1980-04-01

    A test method and spectrometer has been developed for emission-spectrometrical measurement of the deuterium content in water enriched with deuterium. The water sample is melted into a previously evacuated glas tube and a gas discharge is excited in vapour over the cooled sample to adjust to a low vapour pressure with high frequency. The intensities of the H(α) and D(α) lines appearing in the spectrum determine the D-content. Both lines were resolved by a Fabry-Perot interferometer and geometrically separated fed to two photodetectors. The remaining spectrum is filtered off. Following electronic calculation of the signals, the measured value is indicated which has to be corrected by a standard curve. The relative measuring accuracy is about +-1% for enrichments of over 1% D and less than +-5% in the region of 0.3-1% D. The detection limit is about 0.03% D (sample amount: 50 μl, average of 5 samples). (orig./HP) [de

  6. Gas chromatographic/mass spectrometric determination of carbon isotope composition in unpurified samples: methamphetamine example.

    Science.gov (United States)

    Low, I A; Liu, R H; Legendre, M G; Piotrowski, E G; Furner, R L

    1986-10-01

    A gas chromatograph/quadrupole mass spectrometer system, operated in electron impact/selected ion monitoring mode, is used to determine the intensity ratio of the m/z 59 and the m/z 58 ions of the [C3H8N]+ fragment derived from methamphetamine samples synthesized with varying amounts of 13C-labeled methylamine. Crude products are introduced into the gas chromatograph without prior cleanup. The ratios measured were in excellent agreement with those calculated. A change in 0.25% use of 13C-methylamine is sufficient for product differentiation. The feasibility of using isotope labeling and subsequent mass spectrometric isotope ratio measurement as the basis of a compound tracing mechanism is discussed. Specifically, if methamphetamine samples manufactured from legal sources are asked to incorporate distinct 13C compositions, their sources can be traced when samples are diverted into illegal channels. Samples derived from illicit preparations can also be traced if the manufacturers of a precursor (methylamine in this case) incorporate distinct 13C compositions in their products.

  7. Atomic absorption spectrometric determination of copper, zinc, and lead in geological materials

    Science.gov (United States)

    Sanzolone, R.F.; Chao, T.T.

    1976-01-01

    An atomic absorption spectrometric method is described for the determination of copper, zinc, and lead in geological materials. The sample is digested with HF-HCl-H2O2; the final solution for analysis is in 10 % (v/v) HCl. Copper and zinc are determined directly by aspirating the solution into an air-acetylene flame. A separate aliquot of the solution is used for determination of lead; lead is extracted into TOPO-MIBK from the acidic solution in the presence of iodide and ascorbic acid. For a 0.50-g sample, the limits of determination are 10-2000 p.p.m. for Cu and Zn, and 5-5000 p.p.m. for Pb. As much as 40 % Fe or Ca. and 10 % Al, Mg, or Mn in the sample do not interfere. The proposed method can be applied to the determination of copper, zinc, and lead in a wide range of geological materials including iron- and manganese-rich, calcareous and carbonate samples. ?? 1976.

  8. Mass spectrometric study of rhamnolipid biosurfactants and their interactions with cell membrane phospholipids

    Directory of Open Access Journals (Sweden)

    Pashynska V. A.

    2009-12-01

    Full Text Available Aim. To examine the formation of supramolecular complexes of biogenous rhamnolipids with membrane phospholipids that is considered as a molecular mechanism of the biosurfactants antimicrobial action. Method. In the present work rhamnolipid biosurfactant samples produced by Pseudomonas sp. PS-17 strain have been investigated by electrospray ionization mass spectrometry for the first time. Results. As a result of the study, characteristic mass spectra of the rhamnolipid samples were obtained, that can be used as reference spectra for mass spectrometric identification of the compounds in any biological or industrial samples. At the next stage of the experiments the pair systems, containing the biosurfactants and a membrane phospholipid dipalmitoylphosphatidylcholine, have been tested. The cationized noncovalent complexes of the rhamnolipids with the phospholipid were observed in the spectra. Conclusions. The results obtained testify to the consideration that rhamnolipids (similar to other membranotropic agents can form stable supramolecular complexes with membrane phospholipids that are able to evoke the biosurfactants antimicrobial action. A great potential of electrospray ionization mass spectrometry for the biosurfactants identification and study has been demonstrated in the work.

  9. Quantum dots assisted laser desorption/ionization mass spectrometric detection of carbohydrates: qualitative and quantitative analysis.

    Science.gov (United States)

    Bibi, Aisha; Ju, Huangxian

    2016-04-01

    A quantum dots (QDs) assisted laser desorption/ionization mass spectrometric (QDA-LDI-MS) strategy was proposed for qualitative and quantitative analysis of a series of carbohydrates. The adsorption of carbohydrates on the modified surface of different QDs as the matrices depended mainly on the formation of hydrogen bonding, which led to higher MS intensity than those with conventional organic matrix. The effects of QDs concentration and sample preparation method were explored for improving the selective ionization process and the detection sensitivity. The proposed approach offered a new dimension to the application of QDs as matrices for MALDI-MS research of carbohydrates. It could be used for quantitative measurement of glucose concentration in human serum with good performance. The QDs served as a matrix showed the advantages of low background, higher sensitivity, convenient sample preparation and excellent stability under vacuum. The QDs assisted LDI-MS approach has promising application to the analysis of carbohydrates in complex biological samples. Copyright © 2016 John Wiley & Sons, Ltd.

  10. A Chemical Eight Group Separation Method for Routine Use in Gamma Spectrometric Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Samsahl, K

    1961-04-15

    A method for the separation of chemical elements in 8 groups suitable for gamma spectrometric analysis has been developed. One group of elements is separated by distillation during dissolution of the sample. The other groups are obtained by means of short ion exchange columns coupled in series An anion exchange column saturated with chloride ions separates chloride complexes, peroxides and other anions from a 3-n HCl + 0.3 % H{sub 2}O{sub 2} sample solution. Some of the chloride complexes are eluted with 0.1-n HCl + 0.3 % H{sub 2}O{sub 2} and subsequently adsorbed as cations on a cation exchange column in hydrogen form. A few eluted elements which do not form cations in this case are found in the effluent. Elements passing the anion exchange column in chloride form without adsorption are separated from a H{sub 2}O solution as citrate complexes, hydroxides, cations and hexametaphosphate complexes. This is done by coupling in series two anion exchange columns subsequently in citrate and hydroxide form and followed by a cation exchanger in sodium form. A mixed bed column ends the series. The behaviour in the separation series of most elements forming gamma emitting isotopes with half lives exceeding 10 minutes on irradiation with thermal neutrons has been studied. The method has been used, routinely for one year.

  11. Radiometric and spectrometric analysis of boron-containing rocks in boreholes

    International Nuclear Information System (INIS)

    Vakhtin, B.S.; Ivanov, V.S.; Semenov, V.I.

    1973-01-01

    Gamma-logging, neutron-gamma logging and neutron-resonance logging were carried out when exploring the boron-containing wells. Spectrometry of natural and capture gamma-radiation, of the induced radioactivity was performed in particular points of the wells. Continuous measurements were done with the PRKS-2 logging radiometer, spectrometric measurements - with a simulator of a well rig of 130 mm outer dia. (NaI crystal, 63x63 mm) and the AI-128 pulse analyzer. The time of getting gamma-logging spectra is 16 min, that of neutron-gamma logging is 8 min. When measuring the induced radioactivity, the time of activation is 35 min., the time-out - 1 min., the time of measurement measurement - 32 min.; the neutron gamma- logging probe is 35 cm long, the probe used in activation measurements is 2 cm long. It has been observed that porphyrites and garnetiferous rocks are distinguished by elevated readings on the gamma-logging and neutron-resonance logging curves, whereas boron-containing rocks - by lowered readings in neutron-gamma logging and neutron-resonance logging. In the gamma-logging spectra the lines of uranium-radium, potassium and thorium are observed, in neutron-gamma logging spectra - the lines of silicon, calcium and hydrogen, in the induced radioactivity spectra - Al 28 and Mn 56

  12. Sequence-specific capture of protein-DNA complexes for mass spectrometric protein identification.

    Directory of Open Access Journals (Sweden)

    Cheng-Hsien Wu

    Full Text Available The regulation of gene transcription is fundamental to the existence of complex multicellular organisms such as humans. Although it is widely recognized that much of gene regulation is controlled by gene-specific protein-DNA interactions, there presently exists little in the way of tools to identify proteins that interact with the genome at locations of interest. We have developed a novel strategy to address this problem, which we refer to as GENECAPP, for Global ExoNuclease-based Enrichment of Chromatin-Associated Proteins for Proteomics. In this approach, formaldehyde cross-linking is employed to covalently link DNA to its associated proteins; subsequent fragmentation of the DNA, followed by exonuclease digestion, produces a single-stranded region of the DNA that enables sequence-specific hybridization capture of the protein-DNA complex on a solid support. Mass spectrometric (MS analysis of the captured proteins is then used for their identification and/or quantification. We show here the development and optimization of GENECAPP for an in vitro model system, comprised of the murine insulin-like growth factor-binding protein 1 (IGFBP1 promoter region and FoxO1, a member of the forkhead rhabdomyosarcoma (FoxO subfamily of transcription factors, which binds specifically to the IGFBP1 promoter. This novel strategy provides a powerful tool for studies of protein-DNA and protein-protein interactions.

  13. Vaporization of niobium dioxide by mass-effusion and mass-spectrometric methods

    International Nuclear Information System (INIS)

    Kamegashira, N.; Matsui, T.; Harada, M.; Naito, K.

    1981-01-01

    The congruence of the vaporization process of NbO, NbO 2 , Nb 12 O 29 and Nb 2 O 5 in the niobium-oxygen system was investigated from the phase change of the solid residue after vaporization, and it was observed that only the NbO 2 phase vaporizes congruently. The vapor pressures over NbO 2 (s) were measured by means of a combination of mass-effusion (weight loss measurement) and mass-spectrometric methods in the temperature range 1953-2323 K. By applying the second and the third law treatments of thermodynamics to the partial pressures of the gaseous species NbO 2 (g), NbO(g) and O(g), the enthalpies of vaporization for the reactions NbO 2 (s,1)=NbO 2 (g) and NbO 2 (s,1)=NbO(g)+O(g), were calculated. From these data the enthalpies of formation and the dissociation energies of NbO 2 (g) and NbO(g) were also determined. The uncertainties included in the third law treatment were discussed, and the results calculated by the third law treatment using the most reliable data available at present were presented. (orig.)

  14. Vaporization study on vanadium-oxygen solid solution by mass spectrometric method

    International Nuclear Information System (INIS)

    Banchorndhevakul, W.; Matsui, Tsuneo; Naito, Keiji

    1986-01-01

    The vapor pressures over vanadium-oxygen solid solution (0.001 ≤ O/V ≤ 0.145) were measured by mass-spectrometric method in the temperature range of 1,855 ∼ 2,117 K. The main vapor species were observed to be V(g) and VO(g). The vapor pressure of V(g) is higher than that of VO(g) over the solid solutions with all O/V ratios except for O/V = 0.145. The vapor pressure of V(g) is nearly independent of O/V ratio. The vapor pressure of VO(g) decreases with decreasing O/V ratio. The oxygen partial pressure was calculated as a function of temperature and O/V ratio from the vapor pressures of V(g) and VO(g), from which the partial molar enthalpy and entropy of oxygen in the solid solution were determined. The partial molar enthalpy of oxygen was observed to be independent of composition, suggesting the presence of very weak interaction between interstitial oxygens. The compositional dependence of the partial molar entropy of oxygen can be explained by assuming the occupation of the octahedral site in bcc vanadium lattice by the interstitial oxygens. The excess partial molar entropy of oxygen was compared with the value derived from the sum of the contributions from the volume expansion, electronic heat capacity and vibrational terms. (author)

  15. Mass spectrometric behaviour of carboxylated polyethylene glycols and carboxylated octylphenol ethoxylates.

    Science.gov (United States)

    Frańska, Magdalena; Zgoła, Agnieszka; Rychłowska, Joanna; Szymański, Andrzej; Łukaszewski, Zenon; Frański, Rafał

    2003-01-01

    Mass spectrometric behaviour of mono- and di-carboxylated polyethylene glycols (PEGCs and CPEGCs) and carboxylated octylphenol ethoxylates (OPECs) are discussed. The tendency for ionisation (deprotonation, protonation and cationisation by alkali metal cations) of carboxylated PEGs was compared with that of non-carboxylated correspondents by using both secondary ion mass spectrometry (SIMS) and electrospray ionisation (ESI). The fragmentation of the PEGCs and CPEGCs is discussed and also compared with their neutral correspondents, PEGs. The B/E mass spectra were recorded, using secondary ion mass spectrometry as a method for generation, for deprotonated and protonated molecules and molecules cationised by alkali metal cations. The fragmentation behaviour of PEGs is found to be different from that of CPEGCs, The presence of carboxylic groups may be confirmed not only by the determination of molecular weights of the ethoxylates studied, but also on the basis of the fragment ions formed. The metastable decomposition of the [OPEC-H](-) ions proceed through the cleavage of the bond between the octylphenol moiety and the ethoxylene chain leading to the octylphenoxy anions. It permits determination of the mass of the hydrophobic moiety of the studied carboxylated alkylphenol ethoxylate. ESI mass spectra recorded in the negative ion mode were found to be more suitable for the determination of the average molecular weight of carboxylated ethoxylates than SI mass spectra.

  16. Standard methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of uranium hexafluoride

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    All methods described for subsampling and analysis of UF 6 are in routine use at United States Atomic Energy Commission installations. A gravimetric method is included for U and titrimetric methods, for Cl 2 and U. Mass spectrometric methods are given for both double and single standard procedures for U-isotopic content and for semiquantitative determination of hydrocarbons, chlorocarbons, and partially substituted halohydrocarbons. Spectroscopic methods are described for 232 U, fission products, Pu, and Np. In some instances an ion exchange- or extraction-separation is specified prior to the spectroscopic determination. Mass spectroscopic procedures for 31 trace elements are included, as are spectrophotometric methods for Br 2 , Si, P, Ti, V, W, Th, and Mo. Following a preliminary separation for some elements, emission spectroscopic procedures are described for B, Si, Ru, Hf, Mo, Nb, Ta, Ti, W, Zr, V, Th, rare earths, and other elements. Procedures for the determination of Sb, Ru, Al, Cd, Co, Ca, Cr, Fe, Pb, Mg, Mn, Ni, K, Na, and Zn by atomic absorption methods are included. The preparation of high-purity U 3 O 8 by the hydrolysis of UF 6 to UO 2 F 2 which upon drying and pyrohydrolysis yields U 3 O 8 is described

  17. Validation of a UV Spectrometric Method for the Assay of Tolfenamic Acid in Organic Solvents

    Directory of Open Access Journals (Sweden)

    Sofia Ahmed

    2015-01-01

    Full Text Available The present study has been carried out to validate a UV spectrometric method for the assay of tolfenamic acid (TA in organic solvents. TA is insoluble in water; therefore, a total of thirteen commonly used organic solvents have been selected in which the drug is soluble. Fresh stock solutions of TA in each solvent in a concentration of 1 × 10−4 M (2.62 mg% were prepared for the assay. The method has been validated according to the guideline of International Conference on Harmonization and parameters like linearity, range, accuracy, precision, sensitivity, and robustness have been studied. Although the method was found to be efficient for the determination of TA in all solvents on the basis of statistical data 1-octanol, followed by ethanol and methanol, was found to be comparatively better than the other studied solvents. No change in the stock solution stability of TA has been observed in each solvent for 24 hours stored either at room (25±1°C or at refrigerated temperature (2–8°C. A shift in the absorption maxima has been observed for TA in various solvents indicating drug-solvent interactions. The studied method is simple, rapid, economical, accurate, and precise for the assay of TA in different organic solvents.

  18. Column preconcentration and electrothermal atomic absorption spectrometric determination of rhodium in some food and standard samples.

    Science.gov (United States)

    Taher, Mohammad Ali; Pourmohammad, Fatemeh; Fazelirad, Hamid

    2015-12-01

    In the present work, an electrothermal atomic absorption spectrometric method has been developed for the determination of ultra-trace amounts of rhodium after adsorption of its 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol/tetraphenylborate ion associated complex at the surface of alumina. Several factors affecting the extraction efficiency such as the pH, type of eluent, sample and eluent flow rates, sorption capacity of alumina and sample volume were investigated and optimized. The relative standard deviation for eight measurements of 0.1 ng/mL of rhodium was ±6.3%. In this method, the detection limit was 0.003 ng/mL in the original solution. The sorption capacity of alumina and the linear range for Rh(III) were evaluated as 0.8 mg/g and 0.015-0.45 ng/mL in the original solution, respectively. The proposed method was successfully applied for the extraction and determination of rhodium content in some food and standard samples with high recovery values. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Synoptic view of the different domains of application of airborne radiometric and spectrometric surveys in egypt

    International Nuclear Information System (INIS)

    Fouad, K.M.

    1998-01-01

    Airborne radiometric survey has been applied for more than three decades in egypt. Experience gained from the acquired data over different geological environments has revealed the importance of this geophysical tool in: 1. disclosure of anomalies of potential uranium deposits, 2. geological mapping, 3. environmental monitoring of natural radiometric background around nuclear facilities, as well as the detection of nuclear fallout resulting from local or foreign nuclear activities. The advent of recording of the discriminated gamma ray energies in the airborne 256-channel spectrometer has eventually resulted in the quantitative detection of uranium, thorium, and potassium and their elemental ratios in the rocks. This has greatly widened the scope of geophysical and geochemical application. When this type is coupled with airborne magnetometry, the geological and structural configuration is appreciably revealed in three dimensions. The important role played by the statistical method of analysis is also shown. Case histories from the eastern desert, and sinai peninsula, are exhibited to help manifest the wide variety of applications of radiometric and spectrometric surveys

  20. Analysis of Endocrine Disrupting Pesticides by Capillary GC with Mass Spectrometric Detection

    Directory of Open Access Journals (Sweden)

    Svetlana Hrouzková

    2012-09-01

    Full Text Available Endocrine disrupting chemicals, among them many pesticides, alter the normal functioning of the endocrine system of both wildlife and humans at very low concentration levels. Therefore, the importance of method development for their analysis in food and the environment is increasing. This also covers contributions in the field of ultra-trace analysis of multicomponent mixtures of organic pollutants in complex matrices. With this fact conventional capillary gas chromatography (CGC and fast CGC with mass spectrometric detection (MS has acquired a real importance in the analysis of endocrine disrupting pesticide (EDP residues. This paper provides an overview of GC methods, including sample preparation steps, for analysis of EDPs in a variety of matrices at ultra-trace concentration levels. Emphasis is put on separation method, mode of MS detection and ionization and obtained limits of detection and quantification. Analysis time is one of the most important aspects that should be considered in the choice of analytical methods for routine analysis. Therefore, the benefits of developed fast GC methods are important.

  1. Mass Spectrometric Methodologies for Investigating the Metabolic Signatures of Parkinson's Disease: Current Progress and Future Perspectives.

    Science.gov (United States)

    Gill, Emily L; Koelmel, Jeremy P; Yost, Richard A; Okun, Michael S; Vedam-Mai, Vinata; Garrett, Timothy J

    2018-03-06

    Parkinson's disease (PD) is a neurodegenerative disorder resulting from the loss of dopaminergic neurons of the substantia nigra as well as degeneration of motor and nonmotor basal ganglia circuitries. Typically known for classical motor deficits (tremor, rigidity, bradykinesia), early stages of the disease are associated with a large nonmotor component (depression, anxiety, apathy, etc.). Currently, there are no definitive biomarkers of PD, and the measurement of dopamine metabolites does not allow for detection of prodromal PD nor does it aid in long-term monitoring of disease progression. Given that PD is increasingly recognized as complex and heterogeneous, involving several neurotransmitters and proteins, it is of importance that we advance interdisciplinary studies to further our knowledge of the molecular and cellular pathways that are affected in PD. This approach will possibly yield useful biomarkers for early diagnosis and may assist in the development of disease-modifying therapies. Here, we discuss preanalytical factors associated with metabolomics studies, summarize current mass spectrometric methodologies used to evaluate the metabolic signature of PD, and provide future perspectives of the rapidly developing field of MS in the context of PD.

  2. Contribution to the study of once-forbidden {beta} transitions. Case of {sup 42}K and {sup 86}Rb; Contribution a l'etude des transitions {beta} une fois interdites. Cas de K{sup 42} et Rb{sup 86}

    Energy Technology Data Exchange (ETDEWEB)

    Andre, St [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1965-10-01

    An apparatus has been developed for studying the exact shape of the spectra of {beta} transitions which lead to an excited state of the final nucleus, using a Siegbahn-Slattis {beta} spectrometer. In particular the {beta} spectrum of the 2- {yields} 2+ transition of {sup 42}K has been measured; a considerable deviation has been found with respect to the statistical shape. The six elements of the nuclear matrices for this transition have been determined using this measurement and other results. It is shown that it cannot be explained by a pure f7/2 {yields} d3/2 transition. Furthermore the value obtained for the ratio of the matrix elements {integral}{alpha} and {integral}r is in excellent agreement with that predicted from the theory for the maintained vectorial current. (author) [French] On a realise et mis au point un appareillage permettant l'etude des formes precises des spectres {beta} des transitions aboutissant a un etat excite du noyau final sur un spectrometre {beta} Siegbahn-Slatis. On a mesure notamment le spectre {beta} de la transition 2- {yields} 2+ du K{sup 42}, mettant en evidence une deviation importante par rapport a la forme statistique. A partir de cette mesure et d'autres resultats, on a determine les six elements de matrice nucleaires de cette transition. On montre qu'elle ne peut pas etre expliquee par une transition f7/2 {yields} d3/2 pure. D'autre part, la valeur obtenue pour le rapport des elements de matrice {integral}{alpha} et {integral}r est en excellent accord avec celle qui est prevue a partir de la theorie du courant vectoriel conserve. (auteur)

  3. Experimental techniques; Techniques experimentales

    Energy Technology Data Exchange (ETDEWEB)

    Roussel-Chomaz, P. [GANIL CNRS/IN2P3, CEA/DSM, 14 - Caen (France)

    2007-07-01

    This lecture presents the experimental techniques, developed in the last 10 or 15 years, in order to perform a new class of experiments with exotic nuclei, where the reactions induced by these nuclei allow to get information on their structure. A brief review of the secondary beams production methods will be given, with some examples of facilities in operation or under project. The important developments performed recently on cryogenic targets will be presented. The different detection systems will be reviewed, both the beam detectors before the targets, and the many kind of detectors necessary to detect all outgoing particles after the reaction: magnetic spectrometer for the heavy fragment, detection systems for the target recoil nucleus, {gamma} detectors. Finally, several typical examples of experiments will be detailed, in order to illustrate the use of each detector either alone, or in coincidence with others. (author)

  4. Etudes optiques de nouveaux materiaux laser: Des orthosilicates dopes a l'ytterbium: Le yttrium (lutetium,scandium) pentoxide de silicium

    Science.gov (United States)

    Denoyer, Aurelie

    La decouverte et l'elaboration de nouveaux materiaux laser solides suscitent beaucoup d'interet parmi la communaute scientifique. En particulier les lasers dans la gamme de frequence du micron debouchent sur beaucoup d'applications, en telecommunication, en medecine, dans le domaine militaire, pour la, decoupe des metaux (lasers de puissance), en optique non lineaire (doublage de frequence, bistabilite optique). Le plus couramment utilise actuellement est le Nd:YAG dans cette famille de laser, mais des remplacants plus performants sont toujours recherches. Les lasers a base d'Yb3+ possedent beaucoup d'avantages compares aux lasers Nd3+ du fait de leur structure electronique simple et de leur deterioration moins rapide. Parmi les matrices cristallines pouvant accueillir l'ytterbium, les orthosilicates Yb:Y 2SiO5, Yb:Lu2SiO5 et Yb:Sc2SiO 5 se positionnent tres bien, du fait de leur bonne conductivite thermique et du fort eclatement de leur champ cristallin necessaire a l'elaboration de lasers quasi-3 niveaux. De plus l'etude fine et systematique des proprietes microscopiques de nouveaux materiaux s'avere toujours tres interessante du point de vue de la recherche fondamentale, c'est ainsi que de nouveaux modeles sont concus (par exemple pour le champ cristallin) ou que de nouvelles proprietes inhabituelles sont decouvertes, menant a de nouvelles applications. Ainsi d'autres materiaux dopes a l'ytterbium sont connus pour leurs proprietes de couplage electron-phonon, de couplage magnetique, d'emission cooperative ou encore de bistabilite optique, mais ces proprietes n'ont encore jamais ete mises en evidence dans Yb:Y 2SiO5, Yb:Lu2SiO5 et Yb:Sc2SiO 5. Ainsi, cette these a pour but l'etude des proprietes optiques et des interactions microscopiques dans Yb:Y2SiO 5, Yb:Lu2SiO5 et Yb:Sc2SiO5. Nous utilisons principalement les techniques d'absorption IR et de spectroscopie Raman pour determiner les excitations du champ cristallin et les modes de vibration dans le materiau

  5. The application of radioactive isotopes to the study of motion of silt and pebbles in the rivers and in the sea; Application des isotopes radioactifs a l'etude des mouvements des sediments et des galets dans les cours d'eau et en mer

    Energy Technology Data Exchange (ETDEWEB)

    Hours, R [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Jaffry, P [Electricite de France (EDF), 78 - Chatou (France). Lab. National d' Hydraulique

    1959-07-01

    The application of radioactive tracers to the study of sediments drift has received considerable attention since 1954 in various countries. A comparative review is made of a number of techniques of labelling, immersing and detecting silts, sands, and pebbles. The influence of the burying of the active material is emphasized. The different experiments which have been so far carried out are described. (author) [French] L'application des traceurs radioactifs a l'etude des deplacements de sediments a fait depuis 1954 l'objet de travaux nombreux dans divers pays. On passe en revue et on compare differentes techniques de marquage, d'immersion et de detection des vases, sables et galets; on insiste sur l'influence de l'enfouissement du materiau actif. On decrit les differentes experiences effectuees jusqu'a ce jour. (auteur)

  6. Method Validation for the Gamma-ray Spectrometric Determination of Natural Radioactive Nuclides in NORM Samples - Method Validation for the Gamma-ray Spectrometric Determination of Natural Radionuclides in raw materials and by-products

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Young-Yong; Lim, Jong-Myoung; Jang, Mee; Kim, Chang-Jong; Chung, Kun Ho; Kang, Mun Ja; Choi, Geun-Sik [Environmental Radioactivity Assessment Team, Korea Atomic Energy Research Institute, 111, Daedeok-daero 989, Yuseong, Daejeon, 305-353 (Korea, Republic of)

    2014-07-01

    It has established the 'Act on safety control of radioactive rays around living environment' in Korea, since 2011, to protect the public from natural occurring radioactive materials (NORM) and their by-products. The increasing concerns regarding the radioactivity of those materials therefore dictate many demands for the radioactive analysis for them. There are several methods to determine the concentration of natural radionuclides, such as {sup 235}U, {sup 238}U, {sup 226}Ra, {sup 232}Th, and so on, through a radiochemical analysis using an alpha spectrometer, mass spectrometer and liquid scintillation counter. However, gamma-ray spectroscopy still has an effect on the assessment of radioactive concentration for these nuclides and their progenies. To adapt a gamma spectrometer to the determination of natural radionuclides, the feasibility of their analysis methods should be first verified and validated with respect to accuracy and time and cost constraints. In general, one of the well-known processes in analyzing uranium with a gamma spectrometer is an indirect measurement using the secular equilibrium state with their progenies in a sample. This method, however, demands the time elapsed about 3 weeks to reach the equilibrium state between {sup 226}Ra and {sup 222}Rn and the sufficient integrity of a sample bottle to prevent the leakage of radon isotopes which is a form of noble gas. The simple and quick method is to directly measure a full energy absorption peak of 186.2 keV from {sup 226}Ra without the secular equilibrium state between {sup 226}Ra and {sup 222}Rn in the common sample bottle. However, this direct measurement also has difficulties about the interference with a full energy absorption peak of 185.7 keV from {sup 235}U. In this study, direct measurement with the interference correction technique, which uses several reference peaks for gamma-rays from {sup 235}U and {sup 234}Th, and indirect measurement, which means the identification of {sup

  7. Rapid Mass Spectrometric Analysis of a Novel Fucoidan, Extracted from the Brown Alga Coccophora langsdorfii

    Directory of Open Access Journals (Sweden)

    Stanislav D. Anastyuk

    2014-01-01

    Full Text Available The novel highly sulfated (35% fucoidan fraction Cf2 , which contained, along with fucose, galactose and traces of xylose and uronic acids was purified from the brown alga Coccophora langsdorfii. Its structural features were predominantly determined (in comparison with fragments of known structure by a rapid mass spectrometric investigation of the low-molecular-weight fragments, obtained by “mild” (5 mg/mL and “exhaustive” (maximal concentration autohydrolysis. Tandem matrix-assisted laser desorption/ionization mass spectra (MALDI-TOF/TOFMS of fucooligosaccharides with even degree of polymerization (DP, obtained by “mild” autohydrolysis, were the same as that observed for fucoidan from Fucus evanescens, which have a backbone of alternating (1 → 3- and (1 → 4 linked sulfated at C-2 and sometimes at C-4 of 3-linked α-L-Fucp residues. Fragmentation patterns of oligosaccharides with odd DP indicated sulfation at C-2 and at C-4 of (1 → 3 linked α-L-Fucp residues on the reducing terminus. Minor sulfation at C-3 was also suggested. The “exhaustive” autohydrolysis allowed us to observe the “mixed” oligosaccharides, built up of fucose/xylose and fucose/galactose. Xylose residues were found to occupy both the reducing and nonreducing termini of FucXyl disaccharides. Nonreducing galactose residues as part of GalFuc disaccharides were found to be linked, possibly, by 2-type of linkage to fucose residues and were found to be sulfated, most likely, at position C-2.

  8. Mass spectrometric analysis of electrophoretically separated allergens and proteases in grass pollen diffusates

    Directory of Open Access Journals (Sweden)

    Geczy Carolyn L

    2003-09-01

    Full Text Available Abstract Background Pollens are important triggers for allergic asthma and seasonal rhinitis, and proteases released by major allergenic pollens can injure airway epithelial cells in vitro. Disruption of mucosal epithelial integrity by proteases released by inhaled pollens could promote allergic sensitisation. Methods Pollen diffusates from Kentucky blue grass (Poa pratensis, rye grass (Lolium perenne and Bermuda grass (Cynodon dactylon were assessed for peptidase activity using a fluorogenic substrate, as well as by gelatin zymography. Following one- or two-dimensional gel electrophoresis, Coomassie-stained individual bands/spots were excised, subjected to tryptic digestion and analysed by mass spectrometry, either MALDI reflectron TOF or microcapillary liquid chromatography MS-MS. Database searches were used to identify allergens and other plant proteins in pollen diffusates. Results All pollen diffusates tested exhibited peptidase activity. Gelatin zymography revealed high Mr proteolytic activity at ~ 95,000 in all diffusates and additional proteolytic bands in rye and Bermuda grass diffusates, which appeared to be serine proteases on the basis of inhibition studies. A proteolytic band at Mr ~ 35,000 in Bermuda grass diffusate, which corresponded to an intense band detected by Western blotting using a monoclonal antibody to the timothy grass (Phleum pratense group 1 allergen Phl p 1, was identified by mass spectrometric analysis as the group 1 allergen Cyn d 1. Two-dimensional analysis similarly demonstrated proteolytic activity corresponding to protein spots identified as Cyn d 1. Conclusion One- and two-dimensional electrophoretic separation, combined with analysis by mass spectrometry, is useful for rapid determination of the identities of pollen proteins. A component of the proteolytic activity in Bermuda grass diffusate is likely to be related to the allergen Cyn d 1.

  9. Mass spectrometric identification of phospholipids in human tears and tear lipocalin.

    Science.gov (United States)

    Dean, Austin W; Glasgow, Ben J

    2012-04-02

    The purpose of this article was to identify by mass spectrometry phosphocholine lipids in stimulated human tears and determine the molecules bound to tear lipocalin or other proteins. Tear proteins were separated isocratically from pooled stimulated human tears by gel filtration fast performance liquid chromatography. Separation of tear lipocalin was confirmed by SDS tricine gradient PAGE. Protein fractions were extracted with chloroform/methanol and analyzed with electrospray ionization MS/MS triple quadrupole mass spectrometry in precursor ion scan mode for select leaving groups. For quantification, integrated ion counts were derived from standard curves of authentic compounds of phosphatidylcholine (PC) and phosphatidylserine. Linear approximation was possible from integration of the mass spectrometrically obtained ion peaks at 760 Da for the PC standard. Tears contained 194 ng/mL of the major intact PC (34:2), m/z 758.6. Ten other monoisotopic phosphocholines were found in tears. A peak at 703.3 Da was assigned as a sphingomyelin. Four lysophosphatidylcholines (m/z 490-540) accounted for about 80% of the total integrated ion count. The [M+H](+) compound, m/z 496.3, accounted for 60% of the signal intensity. Only the tear lipocalin-bearing fractions showed phosphocholines (104 ng/mL). Although the intact phospholipids bound to tear lipocalin corresponded precisely in mass and relative signal intensity to that found in tears, we did not identify phosphocholines between m/z 490 and 540 in any of the gel-filtration fractions. Phospholipids, predominantly lysophospholipids, are present in tears. The higher mass intact PCs in tears are native ligands of tear lipocalin.

  10. Mature forms of the major seed storage albumins in sunflower: A mass spectrometric approach.

    Science.gov (United States)

    Franke, Bastian; Colgrave, Michelle L; Mylne, Joshua S; Rosengren, K Johan

    2016-09-16

    Seed storage albumins are abundant, water-soluble proteins that are degraded to provide critical nutrients for the germinating seedling. It has been established that the sunflower albumins encoded by SEED STORAGE ALBUMIN 2 (SESA2), SESA20 and SESA3 are the major components of the albumin-rich fraction of the common sunflower Helianthus annuus. To determine the structure of sunflowers most important albumins we performed a detailed chromatographic and mass spectrometric characterization to assess what post-translational processing they receive prior to deposition in the protein storage vacuole. We found that SESA2 and SESA20 each encode two albumins. The first of the two SESA2 albumins (SESA2-1) exists as a monomer of 116 or 117 residues, differing by a threonine at the C-terminus. The second of the two SESA2 albumins (SESA2-2) is a monomer of 128 residues. SESA20 encodes the albumin SESA20-2, which is a 127-residue monomer, whereas SESA20-1 was not abundant enough to be structurally described. SESA3, which has been partly characterized previously, was found in several forms with methylation of its asparagine residues. In contrast to other dicot albumins, which are generally matured into a heterodimer, all the dominant mature sunflower albumins SESA2, SESA20-2, SESA3 and its post-translationally modified analogue SESA3-a are monomeric. Sunflower plants have been bred to thrive in various climate zones making them favored crops to meet the growing worldwide demand by humans for protein. The abundance of seed storage proteins makes them an important source of protein for animal and human nutrition. This study explores the structures of the dominant sunflower napin-type seed storage albumins to understand what structures evolution has favored in the most abundant proteins in sunflower seed. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  11. Study on the bound water of several high specific surface-area oxides (beryllia, alumina, silica-alumina); Etude de l'eau de constitution de plusieurs oxydes a grande surface specifique (glucine, alumine, silice-alumine)

    Energy Technology Data Exchange (ETDEWEB)

    Rouquerol, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-11-01

    This study is concerned with the bound water of several oxides (beryllia, alumina, silica-alumina) at different steps of their dehydration (heating temperatures between 150 and 1100 deg. C). The following techniques have been used simultaneously: Thermal analysis (a new method has been developed), nitrogen adsorption (study of the texture), Diborane hydrolysis (qualitative and quantitative analysis of surface water), Infra-red spectrography (in the absorption range of water), Nuclear magnetic resonance (in the resonance range of protons). Thanks to these different techniques, five kinds of bound water have been observed. Attention is called on the great influence of the thermal treatment conditions on the evolution of the products resulting from the decomposition of alumina {alpha}-trihydrate Al(OH){sub 3} and beryllium {alpha}-hydroxide, in the course of the dehydration. Moreover, the author emphasizes the peculiar properties of the two kinds of oxides (alumina and beryllia) prepared through a new method of treatment under low pressure and constant speed of decomposition. Such particular features concern mainly texture, bound water, and consequently, also catalytic activity. (author) [French] Ce travail porte sur l'eau de constitution de plusieurs oxydes (glucine, alumine, silice-alumine) aux differents degres de leur deshydratation (temperatures de traitement comprises entre 150 et 1100 deg. C). Cette etude met simultanement en oeuvre: l'analyse thermique (proposition d'une nouvelle methode), l'adsorption d'azote (etude de texture), l'hydrolyse du diborane (analyse qualitative et quantitative de l'eau de surface), la spectrographie infra-rouge (dans le domaine d'absorption de l'eau), la resonance magnetique nucleaire (dans le domaine de resonance des protons). A l'aide de ces differentes techniques, cinq formes d'eau de constitution ont ete observees. L'attention est attiree sur la tres grande influence

  12. Study on the bound water of several high specific surface-area oxides (beryllia, alumina, silica-alumina); Etude de l'eau de constitution de plusieurs oxydes a grande surface specifique (glucine, alumine, silice-alumine)

    Energy Technology Data Exchange (ETDEWEB)

    Rouquerol, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-11-01

    This study is concerned with the bound water of several oxides (beryllia, alumina, silica-alumina) at different steps of their dehydration (heating temperatures between 150 and 1100 deg. C). The following techniques have been used simultaneously: Thermal analysis (a new method has been developed), nitrogen adsorption (study of the texture), Diborane hydrolysis (qualitative and quantitative analysis of surface water), Infra-red spectrography (in the absorption range of water), Nuclear magnetic resonance (in the resonance range of protons). Thanks to these different techniques, five kinds of bound water have been observed. Attention is called on the great influence of the thermal treatment conditions on the evolution of the products resulting from the decomposition of alumina {alpha}-trihydrate Al(OH){sub 3} and beryllium {alpha}-hydroxide, in the course of the dehydration. Moreover, the author emphasizes the peculiar properties of the two kinds of oxides (alumina and beryllia) prepared through a new method of treatment under low pressure and constant speed of decomposition. Such particular features concern mainly texture, bound water, and consequently, also catalytic activity. (author) [French] Ce travail porte sur l'eau de constitution de plusieurs oxydes (glucine, alumine, silice-alumine) aux differents degres de leur deshydratation (temperatures de traitement comprises entre 150 et 1100 deg. C). Cette etude met simultanement en oeuvre: l'analyse thermique (proposition d'une nouvelle methode), l'adsorption d'azote (etude de texture), l'hydrolyse du diborane (analyse qualitative et quantitative de l'eau de surface), la spectrographie infra-rouge (dans le domaine d'absorption de l'eau), la resonance magnetique nucleaire (dans le domaine de resonance des protons). A l'aide de ces differentes techniques, cinq formes d'eau de constitution ont ete observees. L'attention est attiree sur la tres grande influence des conditions de traitement thermique sur l'evolution des

  13. Contribution to the study of the sintering of finely divided alumina; Contribution a l'etude du frittage de l'alumine finement divisee

    Energy Technology Data Exchange (ETDEWEB)

    Vergnon, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    Two crystalline forms of alumina, delta and alpha, were used to prepare compacts. The shrinkage of these compacts was investigated at different temperatures. The samples of alumina are composed of non porous, spherical particles, of a very high purity. Their mean diameter varies between 160 and 1 200 Angstrom for the delta alumina samples and between 400 and 1 200 Angstrom for the alpha alumina samples. The shrinkage of compacts, heated at a linearly increasing temperature (300 deg. C/h, slow heating) was studied in a A.D.A.M.E.L. dilatometer, modified to be used as a retractometer. The kinetics of the isothermal shrinkage of compacts after their rapid introduction (a few seconds, flash heating) in the high temperature zone of the furnace were followed with a photographic technique. It is shown that the heating rate influences the shrinkage of the compacts when they are heated at temperatures over 1 000 deg. C. The kinetics of the isothermal shrinkage, at temperature between 1000 deg. C and 1600 deg. C were thoroughly studied. Values of the apparent activation energy for the different classes of compacts are given. An interpretation of the results is proposed. It takes into account two different but interdependent mechanisms of sintering: the disappearance of porosity as a result of vacancy diffusion and the grain growth as a result of boundary migration. (author) [French] Deux formes cristallines de l'alumine, la forme delta et la forme alpha, ont ete utilisees pour confectionner des comprimes en vue d'une etude cinetique du frittage. Ces alumines d'une tres grande purete sont constituees de particules spheriques non poreuses, sensiblement homodispersees dont le diametre moyen varie entre 160 et 1200 Angstrom pour les echantillons de l'alumine delta et entre 400 et 1200 Angstrom pour ceux de l'alumine alpha. Le retrait des comprimes chauffes a temperature linerairement croissante (300 deg. C/h: chauffage lent) a ete suivi a l'aide du dilotometre A

  14. Contribution to the study of the sintering of finely divided alumina; Contribution a l'etude du frittage de l'alumine finement divisee

    Energy Technology Data Exchange (ETDEWEB)

    Vergnon, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    Two crystalline forms of alumina, delta and alpha, were used to prepare compacts. The shrinkage of these compacts was investigated at different temperatures. The samples of alumina are composed of non porous, spherical particles, of a very high purity. Their mean diameter varies between 160 and 1 200 Angstrom for the delta alumina samples and between 400 and 1 200 Angstrom for the alpha alumina samples. The shrinkage of compacts, heated at a linearly increasing temperature (300 deg. C/h, slow heating) was studied in a A.D.A.M.E.L. dilatometer, modified to be used as a retractometer. The kinetics of the isothermal shrinkage of compacts after their rapid introduction (a few seconds, flash heating) in the high temperature zone of the furnace were followed with a photographic technique. It is shown that the heating rate influences the shrinkage of the compacts when they are heated at temperatures over 1 000 deg. C. The kinetics of the isothermal shrinkage, at temperature between 1000 deg. C and 1600 deg. C were thoroughly studied. Values of the apparent activation energy for the different classes of compacts are given. An interpretation of the results is proposed. It takes into account two different but interdependent mechanisms of sintering: the disappearance of porosity as a result of vacancy diffusion and the grain growth as a result of boundary migration. (author) [French] Deux formes cristallines de l'alumine, la forme delta et la forme alpha, ont ete utilisees pour confectionner des comprimes en vue d'une etude cinetique du frittage. Ces alumines d'une tres grande purete sont constituees de particules spheriques non poreuses, sensiblement homodispersees dont le diametre moyen varie entre 160 et 1200 Angstrom pour les echantillons de l'alumine delta et entre 400 et 1200 Angstrom pour ceux de l'alumine alpha. Le retrait des comprimes chauffes a temperature linerairement croissante (300 deg. C/h: chauffage lent) a ete suivi a l'aide du

  15. A rapid method for α-spectrometric analysis of radium isotopes in natural waters using ion-selective membrane technology

    International Nuclear Information System (INIS)

    Purkl, Stefan; Eisenhauer, Anton

    2003-01-01

    An α-spectrometric method for the rapid determination of radium isotopes ( 223 Ra, 224 Ra and 226 Ra) in environmental samples is presented. Using Empore TM Radium Rad Disks complete separation of the target radionuclides is achieved. The high selectivity of these Rad Disks allows the straightforward use of 225 Ra as yield tracer. Chemical yield is up to 92±9%. The chemical procedure can be accomplished within 5 h. α-Sources show energy resolution in the range of typically 26-40 keV (FWHM). Despite minimal thickness of the sources no significant radon (Rn) losses can be observed

  16. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M., E-mail: mlpena@sgc.gov.co; Orozco, J. [Colombian Geological Survey, Nuclear Affairs Technical Division, Neutron Activation Analysis Laboratory, Bogota D. C. (Colombia)

    2016-07-07

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  17. A Chemical Eight Group Separation Method for Routine Use in Gamma Spectrometric Analysis. II. Detailed analytical schema

    Energy Technology Data Exchange (ETDEWEB)

    Samsahl, K

    1961-06-15

    A detailed ion-exchange procedure for the separation of chemical elements in eight groups suitable for subsequent gamma spectrometric analysis is described. The method has been in use for gamma spectrometry of some inorganic - but mostly organic - samples for one year. The separation time for inorganic samples, is usually about 1.5 hours and for organic samples as least 2 hours. One man can separate and count three samples per day. In comparative measurements of short-lived isotopes in biological material 10-12 elements can be analysed thus making possible 30 - 35 determinations per day for one man.

  18. Units for designing multidetector system for spectrometric data storage on the base of the 16Kx24 bit memory device

    International Nuclear Information System (INIS)

    Vagov, V.A.; Korobchenko, M.L.; Sirotin, A.P.

    1985-01-01

    Main units of the system for spectrometric data accumulation on the base of the 16Kx24 bit memory device are considered. Input units: counter unit and unit for organization of analysis are described. The applied method for multiplexing data removed into the counter unit permits to essentially reduce hardware loading. Application of some special functions in the unit for analysis organization simplifies data accumulation control to a large extent. The unit for analysis organization allows application of the memory with an address field up to 64K

  19. Recent progress in the development of CsI(Tl) crystal-Si-photodiode spectrometric detection assemblies

    International Nuclear Information System (INIS)

    Semynozhenko, V.P.; Grinyov, B.V.; Nekrasov, V.V.; Borodenko, Yu.A.

    2005-01-01

    Highly sensitive spectrometric γ-detection assemblies are developed using a comprehensive approach (optimization of crystal growth conditions as well as of treatment and packing of scintillators, creation of low-noise charge-sensitive preamplifiers and shapers). The detection assemblies with CsI(Tl)≤100 cm 3 have a sensitivity of about 20 pulse/s(mcR/h), their energy resolution with respect to 137 Cs γ-line being ≤8.5%. The assemblies with lesser scintillator volumes (1-5 cm 3 ) provide a resolution lower than 6% with respect to 137 Cs and ≤40% with respect to 241 Am

  20. Stable isotope separation; Separations physicochimiques d'isotopes stables realisations et etudes de petites productions

    Energy Technology Data Exchange (ETDEWEB)

    Botter, F; Molinari, Ph; Dirian, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    which cooling water circulates. Studies are going forward to increase the separation factor of the cascade by using an auxiliary gas. Isotopic Exchange: A series of experiments has been performed to determine the isotopic separation factor between a lithium amalgam and an organic solvent containing a lithium salt. The various parameters which may enter into this exchange were studied: the influence of the type of solvent (the two solvents used were dimethylformamide and tetrahydrofurane), of the temperature, of the concentration and of the nature of the associated halogen. Solutions of Li metal and liquid NH{sub 3} were studied also. A number of tests were carried out to see whether there was a difference between the isotopic compositions of the Li present in the two liquid layers obtained by the dissolution of Li metal in ammonia. No difference was observed between the Li isotopic ratios in the two phases. This was also true in the case of a layer of of Li in liquid NH{sub 3} and a layer of Li I in a similar solvent. Electromigration: The method of counter current electro Migration in fused salts is a powerful isotopic enrichment technique. It can be used successfully to separate the isotopes of elements with strongly metallic character. In the case of alkalis, small quantities of isotopically pure {sup 7}Li have been obtained, while the enrichment factors obtained for potassium are of the order of 10. With regard to the alkaline earths, it has been possible to produce small quantities of calcium enriched 5 times in {sup 46}Ca. However considerable technological difficulties rise up in the way of production on a semi-industrial scale. (authors) [French] Nous avons effectue Ia separation de deuterium pur, a partir de melanges gazeux d'hydrogene et de deuterium, par chromatographie de deplacement de bande sur colonnes de palladium supporte. Les meilleures performances ont ete obtenues par des colonnes de Pd sur fritte d'alumine {alpha}. Avec une colonne de ce type, de

  1. Etudes physiques des mélanges eau-cryoprotecteurs

    Science.gov (United States)

    Vassoille, R.; Perez, J.

    The aim of the following review is to present the most important studies concerning the physical properties of water-solutes mixtures used in cryobiology. Cryobiology is a branch of biology which deals with the very low temperature behaviour of cells. This technique is developed today in several directions. The creation of banks of cells and perhaps in a short time of small organs, is the purpose of much research in this domain. Before freezing, living cells are generally put in a solution containing one or more solutes. The role of these solutes is to protect the cells against damage due to crystallization of water (cryoprotectors). The mechanisms of cryoprotection are not well known ; nevertheless the vitreous state formation during cooling is often invoked. So, it is possible to avoid crystallization damage such as mechanical strain (due to an increase of volume of about 10 %) and salt effects (due to osmotic pressure). The conditions in which the vitreous state is obtained, maintained during cooling, storage at low temperature and rewarming can be defined by physical studies presented in the following review. Le présent travail est essentiellement une revue bibliographique des principales études physiques qui ont été réalisées avec des solutions de composés habituellement employés en cryobiologie. La cryobiologie est une branche de la biologie qui s'intéresse au comportement des cellules à basse température. Cette discipline est actuellement en plein développement dans des domaines très divers. Son principal but est la création de banques de cellules de plus en plus complexes avec comme perspective la conservation des organes. Les cellules vivantes sont généralement placées avant congélation dans une solution contenant divers composés dont le rôle est de protéger les cellules contre les effets de la cristallisation de l'eau. L'action protectrice de ces cryoprotecteurs est encore mal connue; cependant, la formation d'un état vitreux lors du

  2. Autoradiographic methods for studying marked volatile substances (1961); Methode.d'etude autoradiographique de substances marquees volatiles (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Y; Wepierre, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    de Pellerin (1957) evite cette dessication, mais la comparaison a l'echelle histologique de l'autoradiographie avec le document biologique lui-meme est difficile sinon impossible. Cependant, nous nous sommes inspire de certains points de chacune des deux methodes pour proposer la technique suivante d'etude autoradiographique de molecules marquees volatiles: 1- nous preparons la surface du bloc congele a autoradiographier a l'aide d'un microtome a congelation; 2- la derniere coupe de 20 {mu} d'epaisseur, dont les elements histologiques font face a ceux du bloc, est dessechee au froid et sert de document biologique de reference a l'autoradiographie obtenue, comme il est indique en 3; 3- les films radiographiques sont appliques sur le bloc congele a -30 deg. C. Les autoradiographies correspondent a la radioactivite de la molecule volatile et de ses produits de degradation non volatils. 4- De plus, le film radiographique est applique sur la coupe de 20 {mu} prealablement dessechee a -20 deg. C. Cette autoradiographie correspond a la radioactivite des produits de degradation non volatils de la molecule. 5- Nous nous sommes assuree de l'absence de diffusion de la molecule volatile et d'effets pseudo-radiographiques (photochimiques et autres). Cette methode qui nous a permis d'etudier la distribution d'un carbure, le paracymene ({sup 14}C) 7 a l'echelle macroscopique sur la souris entiere et a l'echelle microscopique sur la peau de chien, est susceptible d'une application generale. (auteurs)

  3. Contribution to the study of french pitchblendes; Contribution a l'etude des pechblendes francaises

    Energy Technology Data Exchange (ETDEWEB)

    Geffroy, J [Commissariat a l' Energie Atomique, Lab. de Mineralogie, Centre de Chatillon (France). Centre d' Etudes Nucleaires; Sarcia, J A [Commissariat a l' Energie Atomique, Div. de la Crouzille, Haute Vienne (France). Centre d' Etudes Nucleaires

    1955-07-01

    The authors first review the characteristics of uraninite-pitchblende, as deduced of present literature. They set apart from typical pitchblende a black oxide aspect, which probably corresponds to neo-formations, and a 'para-pitchblende' aspect, which they relate to deep sur-oxidation of normal pitchblende. They insist on the easy replacement of pitchblende by silica. and give indications as to changes in vein stones (fluorite, quartz, etc...). A detailed study of paragenesis and successions in french uranium districts follows (including discussion of uranium of uranium-bearing coals). The authors attempt to classify french pitchblende veins. They are chiefly epithermal and poor in satellite ores. Three types of deposits are identified: massive - pitchblende type, silica type, fluorite type. These deposits, as those of Portugal, are included in granite, Central-European peri-batholitic types where uranium associates which Ni, Co, Bi and Ag, are in France both rare and poor. Finally, the authors attempt to bring out in the european Hercynian area a particular distribution of paragenetic types. (authors) [French] Les auteurs recapitulent d'abord les caracteres et les occurences de l'uraninite - pechblende, tels qu'ils peuvent etre degages de l'actuelle bibliographie. Ils exposent ensuite les faits qui du point de vue mineralogique seulement ressortent de l'etude mineralogique et chalcographique des pechblendes francaises et de leurs satellites. Ils distinguent de la pechblende-type un facies oxyde noir; correspondant probablement a une neoformation, et un facies parapechblende, qui est rapporte a une sur oxydation hypogene de la pechblende proprement dite. Ils insistent sur le facile remaniement de la pechblende par la slice; et donnent quelques precisions sur les modifications des gangues (fluorine, quartz, etc...). Suit l'etude detaillee des parageneses et des successions dans les districts uraniferes francais: Divisions du Limousin, de Grury, de Lachaux et de

  4. Study of some properties of zirconium phosphate; Etude de quelques proprietes du phosphate de zirconium

    Energy Technology Data Exchange (ETDEWEB)

    Prospert, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-05-01

    Zirconium phosphate has been studied with a view to using it as an ion exchanger: the first objective was to develop a method of preparation easy to apply and also reproducible. To this end, several tests were carried out varying the molar ratios of phosphorus and of zirconium. Some physical properties such as the diffraction of X-rays were examined. The work then involved certain chemical properties, particularly the percentages of free water and structural water given by the loss on calcination, the Karl-Fisher method and the weight losses by thermogravimetry. Finally an attempts was made to apply the exchanger to the separation of alkaline ions. The static tests showed that the order of fixation of these ions was Cs{sup +} > Rb{sup +} >> K{sup +} > Na{sup +}. Tests with columns showed that Na{sup +} and K{sup +} were easily separable, as was the Rb{sup +}-Cs{sup +} mixture, this last pair being fairly difficult to dissociate. (author) [French] Le phosphate de zirconium a ete etudie en vue de son utilisation comme echangeur d'ions: le premier but a atteindre a ete de mettre au point une preparation pouvant se reveler facilement utilisable ainsi qu'aisement reproductible. A cet effet, plusieurs essais ont ete effectues en faisant varier les rapports molaires du phosphore et du zirconium. Quelques proprietes physiques, telle la diffraction des rayons X, ont ete abordees. Ensuite, l'etude a porte sur certaines proprietes chimiques, particulierement les pourcentages d'eau libre et d'eau de structure par des pertes au feu, utilisation de la methode de Karl-Fisher, ainsi que des pertes de poids a la thenmobalance. Enfin, on a tente d'utiliser l'echangeur a la separation des ions alcalins. Les etudes statiques ont permis de constater que l'ordre de fixation de ces ions etait Cs{sup +} > Rb{sup +} >> K{sup +} > Na{sup +}. Les essais effectues en colonne ont montre que Na{sup +} et K{sup +} etaient aisement separables entre eux, ainsi que du couple Rb{sup +}-Cs{sup +}, ce

  5. Identifying spectrometric signatures of phosphate deposits and enclosing sediments in Al-Awabed area, Northern Palmyrides, Central Syria, by the use of statistical factor analysis

    International Nuclear Information System (INIS)

    Asfahani, J.; Al-Hent, R.; Aissa, M.

    2007-01-01

    In previous published research, a factor analysis approach has been applied to airborne spectrometric data of Al-Awabed area, Northern Palmyrides, Syria. A model of four factors (F1, F2, F3 and F4) has proven to be sufficient to represent the acquired data, where 94% of the total data variance is explained. A powerful tool for direct differentiation of various rocks units is obtained through the mapping of these four factors, where a scored lithological map including 11 radiometric units is established. Ninety nine rock samples have been taken according to the four factors to be analyzed by the gamma spectrometry technique in order to determine their content of e U, e Th and K%. The analysis of 65 samples according to F1 indicates that uranium concentration varies between 2.74 and 123.3 ppm with an average of 58.85 ppm and a standard deviation of 32.53 ppm. The analysis of 18 samples taken according to F2 indicates that K% concentration varies between 0.001 and 0.324 with an average of 0.145 and a standard deviation of 0.122. The analysis of 16 samples taken according to F3 indicates that K% concentration varies between 0.024 and 0.558 with an average of 0.227 and a standard deviation of 0.133. These gamma-results are expected and fit very well with the results obtained by the factor analysis approach. Therefore, the validity and efficacy of the factor analysis approach, to be widely used as a guide in exploration and smart sampling for mining programs, are well demonstrated. The established phosphate maps show a width extension and distribution, and clearly indicate the potential of the research area, and it merits to be followed by economic exploration

  6. Some magnetic resonance properties of solutions of sodium in liquid ammonia; Contribution a l'etude des solutions de sodium dans l'ammoniac liquide par resonance magnetique

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-02-01

    Dilute solutions of sodium in liquid ammonia are studied by the mean of dynamic polarization techniques, and with the aid of Becker Lindquist and Alder model. Paramagnetic shifts are computed as a function of the 'average spin density', for each of the nuclear spin system. The nuclear contributions to the Overhauser shift are computed in the same way. A theoretical study of the main relaxation processes is carried out for each of the nuclear spin system and for the electronic spin system. The dynamic polarization experiments consist in classical measurement of the Overhauser enhancement for nitrogen, and in direct measurements of nitrogen Knight shift and nuclear contributions to the Overhauser shift by the mean of double irradiation techniques. The results show that, in dilute solutions, the relaxation of nitrogen arises from quadrupole interaction and from hyperfine interaction with unpaired electrons. Both interactions are of the same order of magnitude. Overhauser shift measurements show that the spin density is negative at the proton site, in agreement with Hughes results. (author) [French] Les solutions diluees de sodium dans l'ammoniac sont etudiees au moyen des techniques de la polarisation dynamique, sur la base du modele de Becker Lindquist et Aider. Les deplacements paramagnetiques des raies de resonance nucleaire des differents noyaux sont analyses en faisant appel a la notion de ''densite moyenne de spin'' introduite par l'auteur; et les differentes contributions nucleaires au deplacement d'Overhauser sont calculees en fonction de cette meme grandeur. Une etude theorique de la relaxation de chaque systeme de spin permet d'evaluer l'importance relative des differents mecanismes mis en jeu. Les experiences de polarisation dynamique effectuees au cours de ce travail consistent en mesures classiques de l'effet Overhauser sur l'azote, d'une part, et en la mise en oeuvre de techniques originales pour mesurer le deplacement de Knight de l'azote et les

  7. Mutations des roles techniques et formation. Etude documentaire (Changes in the Roles and Education of Technicians. Documentary Study).

    Science.gov (United States)

    Pinard, Helene

    Drawing from research conducted in 1990-91, this report examines trends affecting the future work of technicians in Quebec, their pre-employment education, and the link between college and work. Part 1 focuses on aspects of the economic, technological, and social environment that will influence the future role of technicians. Economic concerns…

  8. Study of filterable materials and protection instruments by the use of radioactive aerosols; Etude de materiaux filtrants et d'appareils de protection a l'aide des aerosols radioactifs

    Energy Technology Data Exchange (ETDEWEB)

    Billard,; Chevalier,; Pradel, [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Many filtration problems can be studied by means of radioactive aerosols. For the investigations described in this paper we have chosen the solid disintegration products of radon, the radioactive gas formed from radium, because of the facilities of generation and measurement it offers. Radon and its daughters are in fact always present in the atmosphere in sufficient concentration for certain tests. In order to improve the sensitivity of the measurements, radon from uranium ore can be used. The technique of measuring by counting {alpha} particles is rapid and easy to employ. We have thus been able to define a test for filterable substances, and to check filtering installation and individual protection instruments. (author) [French] Les aerosols radioactifs permettent d'etudier de nombreux problemes de filtration. Pour les etudes decrites dans ce document, nous avons choisi les produits solides de desintegration du radon, gaz radioactif forme a partir du radium en raison des facilites de generation et de mesure. Le radon et ses descendants sont, en effet, toujours presents dans l'atmosphere en concentration suffisante pour certains essais. Pour ameliorer la sensibilite des mesures, il suffit d'utiliser le radon provenant de minerai d'uranium. La technique de mesure par comptage des particules {alpha} est rapide et facile a mettre en oeuvre. Nous avons pu ainsi definir un test pour les substances filtrantes et controler les installations de filtration et des appareils de protection individuelle. (auteur)

  9. Continuous flow hydride generation-atomic fluorescence spectrometric determination and speciation of arsenic in wine

    Energy Technology Data Exchange (ETDEWEB)

    Karadjova, Irina B. [Faculty of Chemistry, University of Sofia, 1 James Bourchier Blvd., Sofia 1164 (Bulgaria); Lampugnani, Leonardo [C.N.R. Istituto per i processi chimico-fisici, Area della Ricerca di Pisa, Via Moruzzi 1, 56124 Pisa (Italy)]. E-mail: lampugnani@ipcf.cnr.it; Onor, Massimo [C.N.R. Istituto per i processi chimico-fisici, Area della Ricerca di Pisa, Via Moruzzi 1, 56124 Pisa (Italy); D' Ulivo, Alessandro [C.N.R. Istituto per i processi chimico-fisici, Area della Ricerca di Pisa, Via Moruzzi 1, 56124 Pisa (Italy); Tsalev, Dimiter L. [Faculty of Chemistry, University of Sofia, 1 James Bourchier Blvd., Sofia 1164 (Bulgaria)

    2005-07-15

    Methods for the atomic fluorescence spectrometric (AFS) determination of total arsenic and arsenic species in wines based on continuous flow hydride generation (HG) with atomization in miniature diffusion flame (MDF) are described. For hydride-forming arsenic, L-cysteine is used as reagent for pre-reduction and complexation of arsenite, arsenate, monomethylarsonate and dimethylarsinate. Concentrations of hydrochloric acid and tetrahydroborate are optimized in order to minimize interference by ethanol. Procedure permits determination of the sum of these four species in 5-10-fold diluted samples with limit of detection (LOD) 0.3 and 0.6 {mu}g l{sup -1} As in white and red wines, respectively, with precision between 2% and 8% RSD at As levels within 0.5-10 {mu}g l{sup -1}. Selective arsine generation from different reaction media is used for non-chromatographic determination of arsenic species in wines: citrate buffer at pH 5.1 for As(III); 0.2 mol l{sup -1} acetic acid for arsenite + dimethylarsinate (DMA); 8 mol l{sup -1} HCl for total inorganic arsenic [As(III) + As(V)]; and monomethylarsonate (MMA) calculated by difference. Calibration with aqueous and ethanol-matched standard solutions of As(III) is used for 10- and 5-fold diluted samples, respectively. The LODs are 0.4 {mu}g l{sup -1} for As(III) and 0.3 {mu}g l{sup -1} for the other three As species and precision is within 4-8% RSDs. Arsenic species in wine were also determined by coupling of ion chromatographic separation on an anion exchange column and HG-flame AFS detection. Methods were validated by means of recovery studies and comparative analyses by HG-AFS and electrothermal atomic absorption spectrometry after microwave digestion. The LODs were 0.12, 0.27, 0.15 and 0.13 {mu}g l{sup -1} (as As) and RSDs were 2-6%, 5-9%, 3-7% and 2-5% for As(III), As(V), MMA and DMA arsenic species, respectively. Bottled red and white wines from Bulgaria, Republic of Macedonia and Italy were analyzed by non

  10. Basis material decomposition method for material discrimination with a new spectrometric X-ray imaging detector

    Science.gov (United States)

    Brambilla, A.; Gorecki, A.; Potop, A.; Paulus, C.; Verger, L.

    2017-08-01

    Energy sensitive photon counting X-ray detectors provide energy dependent information which can be exploited for material identification. The attenuation of an X-ray beam as a function of energy depends on the effective atomic number Zeff and the density. However, the measured attenuation is degraded by the imperfections of the detector response such as charge sharing or pile-up. These imperfections lead to non-linearities that limit the benefits of energy resolved imaging. This work aims to implement a basis material decomposition method which overcomes these problems. Basis material decomposition is based on the fact that the attenuation of any material or complex object can be accurately reproduced by a combination of equivalent thicknesses of basis materials. Our method is based on a calibration phase to learn the response of the detector for different combinations of thicknesses of the basis materials. The decomposition algorithm finds the thicknesses of basis material whose spectrum is closest to the measurement, using a maximum likelihood criterion assuming a Poisson law distribution of photon counts for each energy bin. The method was used with a ME100 linear array spectrometric X-ray imager to decompose different plastic materials on a Polyethylene and Polyvinyl Chloride base. The resulting equivalent thicknesses were used to estimate the effective atomic number Zeff. The results are in good agreement with the theoretical Zeff, regardless of the plastic sample thickness. The linear behaviour of the equivalent lengths makes it possible to process overlapped materials. Moreover, the method was tested with a 3 materials base by adding gadolinium, whose K-edge is not taken into account by the other two materials. The proposed method has the advantage that it can be used with any number of energy channels, taking full advantage of the high energy resolution of the ME100 detector. Although in principle two channels are sufficient, experimental measurements show

  11. Dosimetric studies, spectrometric, radiographic, metallographic of a new argentinean seed of 125 I used in brachytherapy

    International Nuclear Information System (INIS)

    Pirchio, R.; Saravi, M.; Banchik, D.; Munoz, C.

    2006-01-01

    A new source of 125 I model Braquibac TM has been developed in Argentina for applications in interstitial brachytherapy. The AAPM Task Group 43 (TG-43) recommends that dosimetric characteristics of new sources of brachytherapy of Iodine-125 have been theoretically and experimentally determined before its clinical use. The objectives outlined in this work were the study of the design of the new seed, the calculation of dosimetric parameters and the photons spectra analysis. Its were carried out radiographic and metallographic studies to determine the physical characteristics of the source. For the realization of the dosimetric calculations it was used the Monte Carlo code MCNP5. Values of the radial dose function, g(r), of the constant of dose rate, Λ, of the function of anisotropy of two dimensions, F(r, θ), of the factor and constant of anisotropy its were obtained simulating the source in water according to the recommended methodology in TG-43. The constant of dose rate is similar to 0,880 ± 0,080 c Gy h -1 U -1 . The kerma in air rate of reference, S K , was calculated as 1,036 c Gy cm 2 h -1 mCi -1 simulating the seed in dry air. Its were carried out spectrometric studies using a semiconductor planar detector of HPGe (high purity germanium). Photons spectra showed characteristic x-rays of 125 I with energies of 27,20 keV, 27,47 keV, 31 keV and 31,70 keV gamma photons of 35,5 keV, and x-ray fluorescent coming from the silver nucleus of 22,10 keV, 24,94 keV and 25,45 keV. The angular dependence of the intensity of photons around the seed and in air it was analyzed with the planar detector. This was carried out to study the anisotropy in the photons flow due to variation in the thickness of the titanium wall and of the welding, movements of the silver tube inside the source and deposition of the radioactive material on the silver tube. (Author)

  12. Continuous flow hydride generation-atomic fluorescence spectrometric determination and speciation of arsenic in wine

    International Nuclear Information System (INIS)

    Karadjova, Irina B.; Lampugnani, Leonardo; Onor, Massimo; D'Ulivo, Alessandro; Tsalev, Dimiter L.

    2005-01-01

    Methods for the atomic fluorescence spectrometric (AFS) determination of total arsenic and arsenic species in wines based on continuous flow hydride generation (HG) with atomization in miniature diffusion flame (MDF) are described. For hydride-forming arsenic, L-cysteine is used as reagent for pre-reduction and complexation of arsenite, arsenate, monomethylarsonate and dimethylarsinate. Concentrations of hydrochloric acid and tetrahydroborate are optimized in order to minimize interference by ethanol. Procedure permits determination of the sum of these four species in 5-10-fold diluted samples with limit of detection (LOD) 0.3 and 0.6 μg l -1 As in white and red wines, respectively, with precision between 2% and 8% RSD at As levels within 0.5-10 μg l -1 . Selective arsine generation from different reaction media is used for non-chromatographic determination of arsenic species in wines: citrate buffer at pH 5.1 for As(III); 0.2 mol l -1 acetic acid for arsenite + dimethylarsinate (DMA); 8 mol l -1 HCl for total inorganic arsenic [As(III) + As(V)]; and monomethylarsonate (MMA) calculated by difference. Calibration with aqueous and ethanol-matched standard solutions of As(III) is used for 10- and 5-fold diluted samples, respectively. The LODs are 0.4 μg l -1 for As(III) and 0.3 μg l -1 for the other three As species and precision is within 4-8% RSDs. Arsenic species in wine were also determined by coupling of ion chromatographic separation on an anion exchange column and HG-flame AFS detection. Methods were validated by means of recovery studies and comparative analyses by HG-AFS and electrothermal atomic absorption spectrometry after microwave digestion. The LODs were 0.12, 0.27, 0.15 and 0.13 μg l -1 (as As) and RSDs were 2-6%, 5-9%, 3-7% and 2-5% for As(III), As(V), MMA and DMA arsenic species, respectively. Bottled red and white wines from Bulgaria, Republic of Macedonia and Italy were analyzed by non-chromatographic and chromatographic procedures and the As

  13. Novel technique for coal pyrolysis and hydrogenation production analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pfefferle, L.D.

    1990-01-01

    The overall objective of this study is to establish vacuum ultraviolet photoionization-MS and VUV pulsed EI-MS as useful tools for a simpler and more accurate direct mass spectrometric measurement of a broad range of hydrocarbon compounds in complex mixtures for ultimate application to the study of the kinetics of coal hydrogenation and pyrolysis processes. The VUV-MS technique allows ionization of a broad range of species with minimal fragmentation. Many compounds of interest can be detected with the 118 nm wavelength, but additional compound selectivity is achievable by tuning the wavelength of the photo-ionization source in the VUV. Resonant four wave mixing techniques in Hg vapor will allow near continuous tuning from about 126 to 106 nm. This technique would facilitate the scientific investigation of coal upgrading processes such as pyrolysis and hydrogenation by allowing accurate direct analysis of both stable and intermediate reaction products.

  14. Validation of a stability-indicating spectrometric method for the determination of sulfacetamide sodium in pure form and ophthalmic preparations

    Directory of Open Access Journals (Sweden)

    Sofia Ahmed

    2017-01-01

    Full Text Available Introduction: Sulfacetamide sodium is a widely used sulfonamide for ophthalmic infections. Objective: A number of analytical methods have been reported for the analysis of sulfacetamide but they lack the ability to determine both the active drug and its major degradation product, sulfanilamide, simultaneously in a sample. Materials and Methods: In the present study a simple, rapid and economical stability-indicating UV spectrometric method has been validated for the simultaneous assay of sulfacetamide sodium and sulfanilamide in pure form and in ophthalmic preparations. Results: The method has been found to be accurate (recovery 100.03 ±0.589% and precise (RSD 0.587% with detectable and quantifiable limits of 1.67×10–6 M (0.04 mg% and 5.07×10–6 M (0.13 mg%, respectively for the assay of pure sulfacetamide sodium. The method is also found to be accurate and precise to small changes in wavelength, pH and buffer concentration as well as to forced degradation. The study further includes the validation of the method for the assay of pure sulfanilamide in solution, which has been found to be accurate, precise and robust. Conclusion: The results indicate that the proposed two-component spectrometric method is stability-indicating and can be used for the simultaneous assay of both sulfacetamide sodium and sulfanilamide in synthetic mixtures and degraded solutions.

  15. In situ monitoring of molecular changes during cell differentiation processes in marine macroalgae through mass spectrometric imaging.

    Science.gov (United States)

    Kessler, Ralf W; Crecelius, Anna C; Schubert, Ulrich S; Wichard, Thomas

    2017-08-01

    Matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI) was employed to discriminate between cell differentiation processes in macroalgae. One of the key developmental processes in the algal life cycle is the production of germ cells (gametes and zoids). The gametogenesis of the marine green macroalga Ulva mutabilis (Chlorophyta) was monitored by metabolomic snapshots of the surface, when blade cells differentiate synchronously into gametangia and giving rise to gametes. To establish MSI for macroalgae, dimethylsulfoniopropionate (DMSP), a known algal osmolyte, was determined. MSI of the surface of U. mutabilis followed by chemometric data analysis revealed dynamic metabolomic changes during cell differentiation. DMSP and a total of 55 specific molecular biomarkers, which could be assigned to important stages of the gametogenesis, were detected. Our research contributes to the understanding of molecular mechanisms underlying macroalgal cell differentiation. Graphical abstract Molecular changes during cell differentiation of the marine macroalga Ulva were visualized by matrix assisted laser desorption/ionization mass spectrometric imaging (MALDI-MSI).

  16. Sensitive Mid-IR Laser Sensor Development and Mass Spectrometric Measurements in Shock Tube and Flames

    KAUST Repository

    Alquaity, Awad

    2016-01-01

    CRDS technique was utilized to develop an ultra-fast, high sensitivity diagnostic to monitor trace concentrations of ethylene in shock tube pyrolysis experiments. This diagnostic represented the first ever successful application of CRDS technique

  17. Preparation and study of dialkyl nitroxide radicals; Preparation et etude de radicaux nitroxydes diacyles

    Energy Technology Data Exchange (ETDEWEB)

    Chenavas, P. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    These radicals are obtained by oxidation of N-hydroxy-imides with lead tetracetate or p-nitro-perbenzoic acid. These imides are prepared by heating dicarboxylic acids anhydrides with benzyloxy-amine followed by catalytic hydrogenation of N-benzyloxy-imides so obtained. Two series of radicals have mainly been studied, the first concerning five-membered cyclic imides, the second six-membered cyclic imides, these molecules having methyls substituents or no on the carbon ring. N. M. R. spectra of some O-benzyl-imides have been analysed. These different results have made it possible to study the conformation and stereochemistry of these imides. (author) [French] Ces radicaux sont obtenus par oxydation d'imides N-hydroxyles par le tetracetate de plomb ou l'acide p-nitroperbenzoique; ces imides sont prepares par chauffage d'anhydrides de diacides en presence de benzyloxyamine suivie d'une hydrogenation catalytique des N-benzyloxyimides ainsi obtenus. Deux series de radicaux ont principalement ete etudies: la premiere relative a des imides cycliques a cinq chainons, la seconde a des imides cycliques a six chainons, ces molecules ayant des substituants methyles ou non sur la chaine carbonee. Les derives O-benzyles de quelques-uns de ces imides ont ete analyses en R. M. N. Ces differents resultats ont permis une etude de la conformation et de la stereochimie de ces imides. (auteur)

  18. The abject gaze and the homosexual body: Flandrin's Figure d'Etude.

    Science.gov (United States)

    Camille, M

    1994-01-01

    This article charts the history of the reception, reproduction and appropriation of a single image that has recently become a kind of "gay icon"--the Figure d'Etude in the Louvre, painted by Hippolyte Flandrin in 1835. Initially no more than a neo-classical academic exercise, the formal emptiness of this picture meant that it could be re-invested and reinscribed with new meanings and new titles at every turn. Emblematic of the anxious visibility/invisibility of the newly discovered homosexual body during a period when the gaze still had to be kept a dark secret, Flandrin's image only "came out" in its later photographic reworkings by Frederick Holland Day and Baron von Gloeden. After being reproduced for a specifically homosexual audience early this century, the popular Romantic pose of the young man curled-up in profile became a standard one, reappearing recently in the photographs of Robert Mapplethorpe. The inactive, abject and inward-turned isolation of the figure with its narcissistic self-absorption makes it, in my view, a profoundly negative stereotype of the gay gaze and the homosexual body. Flandrin's figure nonetheless appears today on gay merchandise world-wide as a sign of our separate and secluded subject positions and our community's unwillingness to radically alter older imposed and inherited classical stereotypes.

  19. Study of copper fluorination; Contribution a l'etude de la fluoruration du cuivre

    Energy Technology Data Exchange (ETDEWEB)

    Gillardeau, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-02-01

    This report deals with the action of fluorine on copper. Comprehensive descriptions are given of the particular technological methods and of the preparation of the reactants. This fluorination reaction has been studied at medium and low fluorine pressures. A nucleation and growth phenomenon is described. The influence of a pollution of the gas phase on the fluorination process is described. The solid-state reaction between cupric fluoride and cooper has also been studied. A special study has been made of the growth of copper deposits by thermal decomposition of gaseous fluorides. (author) [French] Ce rapport traite de la reaction du fluor sur le cuivre. Les methodes technologiques particulieres ainsi que les preparations des reactifs sont largement developpees. Cette reaction de fluoruration est etudiee sous pressions moyennes et sous basses pressions de fluor. Un phenomene de germination et croissance est decrit. L'influence de la pollution de la phase gazeuse sur le processus de fluoruration est rapportee. La reaction a l'etat solide du fluorure cuivrique sur le cuivre a egalement ete etudiee. La croissance de depots de cuivre par decomposition thermique des fluorures de cuivre gazeux fait l'objet d'une etude speciale. (auteur)

  20. Preparation and study of dialkyl nitroxide radicals; Preparation et etude de radicaux nitroxydes diacyles

    Energy Technology Data Exchange (ETDEWEB)

    Chenavas, P [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    These radicals are obtained by oxidation of N-hydroxy-imides with lead tetracetate or p-nitro-perbenzoic acid. These imides are prepared by heating dicarboxylic acids anhydrides with benzyloxy-amine followed by catalytic hydrogenation of N-benzyloxy-imides so obtained. Two series of radicals have mainly been studied, the first concerning five-membered cyclic imides, the second six-membered cyclic imides, these molecules having methyls substituents or no on the carbon ring. N. M. R. spectra of some O-benzyl-imides have been analysed. These different results have made it possible to study the conformation and stereochemistry of these imides. (author) [French] Ces radicaux sont obtenus par oxydation d'imides N-hydroxyles par le tetracetate de plomb ou l'acide p-nitroperbenzoique; ces imides sont prepares par chauffage d'anhydrides de diacides en presence de benzyloxyamine suivie d'une hydrogenation catalytique des N-benzyloxyimides ainsi obtenus. Deux series de radicaux ont principalement ete etudies: la premiere relative a des imides cycliques a cinq chainons, la seconde a des imides cycliques a six chainons, ces molecules ayant des substituants methyles ou non sur la chaine carbonee. Les derives O-benzyles de quelques-uns de ces imides ont ete analyses en R. M. N. Ces differents resultats ont permis une etude de la conformation et de la stereochimie de ces imides. (auteur)

  1. Study of {gamma}'s in Naiade; Etude des gamma de Naiade

    Energy Technology Data Exchange (ETDEWEB)

    Millot, J P; Rastoin, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Following a study of the gamma sources, the flux of gamma of different energies in the swimming pool is investigated. The biological dose can thus be obtained by calculation, and compared with the results given by photographic plates. The influence of photoneutrons is estimated by calculation, and research is being carried out on their influence on the thermal neutron flux curve on the axis of the uranium plate, with the plate emitting neutrons and with the plate protected by boral. (author) [French] Apres l'etude des sources de gamma, l'on etudie le flux de gamma de differentes energies dans la piscine. La dose biologique peut etre obtenue ainsi par le calcul et comparee avec les resultats donnes par les plaques photographiques. L'influence des photoneutrons est estimee par le calcul et l'on recherche leur influence sur la courbe de flux de neutrons thermiques sur l'axe de la plaque d'uranium, la plaque emettant des neutrons et la plaque protegee par du boral. (auteur)

  2. Technological study of organic fluids; Etudes technologiques des fluides caloporteurs organique

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    Under contract to EURATOM (MM. VAN der VENNE and HANNAERT), the C.E.A. and the Progil Society have collaborated on a technological study of the terphenyls. The results obtained from the radiolysis and pyrolysis of the product OM2 (70 p. 100 m-terphenyl, 25 p. 100 o-terphenyl, 5 p. 100 p-terphenyl) are reported. Using two pile loops at temperatures up to 450 deg. C, a phenomena of accelerated pyrolysis on the radiolized material has been demonstrated. Some by-products of the petroleum industry have also been studied, with a view to finding substitutes for terphenyl. (author) [French] Le C.E.A. et la Societe PROGIL ont entrepris en commun sous contrat EURATOM (MM. VAN der VENNE et HANNAERT) une etude technologique des terphenyles. Les resultats de radiolyse et de pyrolyse obtenus sur le produit OM2 (70 p. 100 m-terphenyle, 25 p. 100 o-terphenyle. 5 p. 100 de p-terphenyle) sont exposes. L'exploitation de deux boucles en pile jusqu'a des temperatures de 450 deg. C a mis en evidence un phenomene de pyrolyse acceleree sur le produit radiolyse. On a etudie egalement quelques sous-produits de l'industrie petroliere dans le but de trouver des substituts au terphenyle. (auteur)

  3. Underground nuclear explosions. Geological survey of the cavities; Explosions nucleaires souterraines etude geologique des cavites

    Energy Technology Data Exchange (ETDEWEB)

    Faure, J [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1969-07-01

    A geological survey of underground nuclear explosions makes it possible to determine the main characteristics of the cavity formed. The lower portion is spherical; the same was very likely true of the roof, which collapses in the majority of media with the exception of rock-salt. Its radius, for a given bomb size, can vary by a factor of two according to the type of rock. The lay-out of its contents depends on the characteristics of the solid and liquid products at the moment of the roof collapse; according to the medium involved, mixing of the rubble and the mud-flow occurs (granite) or does not occur (tuff and alluvia). In all media, the average physical properties can be evaluated. (author) [French] L'etude geologique d'explosions nucleaires souterraines permet de determiner les principaux caracteres de la cavite creee. Sa partie inferieure est spherique; il en etait vraisemblablement de meme de sa voute, effondree dans la plupart des milieux a l'exception du sel gemme. Son rayon, a energie d'engin egale, varie selon les roches du simple au double. La disposition de son contenu depend des caracteristiques des produits solides et liquides au moment de la chute du toit; selon le cas, il n'y a pas (tuf et alluvions) ou il y a (granite) melange des eboulis et des laves. Dans tous les milieux, les proprietes physiques moyennes peuvent etre evaluees. (auteur)

  4. Dismantling techniques

    International Nuclear Information System (INIS)

    Wiese, E.

    1998-01-01

    Most of the dismantling techniques used in a Decontamination and Dismantlement (D and D) project are taken from conventional demolition practices. Some modifications to the techniques are made to limit exposure to the workers or to lessen the spread of contamination to the work area. When working on a D and D project, it is best to keep the dismantling techniques and tools as simple as possible. The workers will be more efficient and safer using techniques that are familiar to them. Prior experience with the technique or use of mock-ups is the best way to keep workers safe and to keep the project on schedule

  5. Dismantling techniques

    Energy Technology Data Exchange (ETDEWEB)

    Wiese, E.

    1998-03-13

    Most of the dismantling techniques used in a Decontamination and Dismantlement (D and D) project are taken from conventional demolition practices. Some modifications to the techniques are made to limit exposure to the workers or to lessen the spread of contamination to the work area. When working on a D and D project, it is best to keep the dismantling techniques and tools as simple as possible. The workers will be more efficient and safer using techniques that are familiar to them. Prior experience with the technique or use of mock-ups is the best way to keep workers safe and to keep the project on schedule.

  6. Etude exploratoire des conceptions de la circulation sanguine aupres d'eleves de l'ordre collegial

    Science.gov (United States)

    Robitaille, Jean-Marc

    Il existe peu d'etudes sur les conceptions touchant les domaines de la biologie, notamment sur les conceptions de la circulation sanguine Nous avons observe egalement l'absence de recherche menee aupres d'eleves de l'ordre collegial sur cette question. Nous avons voulu combler une lacune en menant une recherche sur les conceptions de la circulation sanguine aupres d'eleves de l'ordre collegial. Pour mener cette recherche nous nous sommes inspires d'une methode developpee par Treagust (1988). Le premier niveau de formulation didactique etablit l'architecture du systeme et la fonction nutritive de la circulation. Le second niveau de formulation didactique decrit et relie les parametres de la dynamique de la circulation et leur relation: Pression, Debit et Resistance. Le troisieme niveau de formulation didactique s'interesse au controle de la circulation du sang dans un contexte d'homeostasie qui implique la regulation de la pression arterielle. Nous avons construit un questionnaire en nous guidant sur les niveaux de formulation didactique et l'analyse des entrevues menees aupres de dix-huit eleves, representatifs de la population cible. Ce questionnaire fut administre a un echantillon de 2300 eleves disperses dans six colleges de la region de Montreal. Notre echantillon comprend des eleves inscrits a des programmes de l'ordre collegial en Sciences de la nature et en Techniques de la sante et qui n'ont pas suivi le cours sur la circulation sanguine. Notre analyse des reponses des eleves de notre echantillon aux questions sur le premier niveau de formulation didactique revele que la majorite des eleves considerent que le systeme circulatoire relie les organes les uns aux autres dans un circuit en serie. Notre analyse revele egalement que la majorite des eleves estiment que les nutriments sont extraits du sang par les organes selon un processus de selection base sur les besoins determines par la fonction de l'organe. Ces besoins sont differents selon les organes qui ne

  7. INTERLABORATORY STUDY OF A THERMOSPRAY-LIQUID CHROMATOGRAPHIC/MASS SPECTROMETRIC METHOD FOR SELECTED N-METHYL CARBAMATES, N-METHYL CARBAMOYLOXIMES, AND SUBSTITUTED UREA PESTICIDES

    Science.gov (United States)

    A thermospray-liquid chromatographic/mass spectrometric (TS-LC/MS) method was evaluated in an interlaboratory study for determining 3 N-methyl carbamates (bendiocarb, carbaryl, and carbofuran), 3-N-methyl carbamoyloximes (aldicarb, methomyl, and oxamyl), 2 substituted urea pestic...

  8. Alkylation of human serum albumin by sulfur mustard in vitro and in vivo : Mass spectrometric analysis of a cysteine adduct as a sensitive biomarker of exposure

    NARCIS (Netherlands)

    Noort, D.; Hulst, A.G.; Jong, L.P.A. de; Benschop, H.P.

    1999-01-01

    To develop a mass spectrometric assay for the detection of sulfur mustard adducts with human serum albumin, the following steps were performed: quantitation of the binding of the agent to the protein by using [14C] sulfur mustard and analysis of acidic and tryptic digests of albumin from blood after

  9. Liquid chromatography-tandem mass spectrometric assay for the tyrosine kinase inhibitor afatinib in mouse plasma using salting-out liquid-liquid extraction

    NARCIS (Netherlands)

    Sparidans, Rolf W; van Hoppe, Stephanie; Rood, Johannes J M; Schinkel, Alfred H; Schellens, Jan H M; Beijnen, Jos H

    2016-01-01

    A quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay for afatinib, an irreversible inhibitor of the ErbB (erythroblastic leukemia viral oncogene homolog) tyrosine kinase family, was developed and validated. Plasma samples were pre-treated using salting-out

  10. Electronic states and nature of bonding in the molecule YC by all electron ab initio multiconfiguration self-consistent-field calculations and mass spectrometric equilibrium experiments

    DEFF Research Database (Denmark)

    Shim, Irene; Pelino, Mario; Gingerich, Karl A.

    1992-01-01

    , and they hardly contribute to the bonding. The chemical bond in the YC molecule is polar with charge transfer from Y to C giving rise to a dipole moment of 3.90 D at 3.9 a.u. in the 4PI ground state. Mass spectrometric equilibrium investigations in the temperature range 2365-2792 K have resulted...

  11. Translation Techniques

    OpenAIRE

    Marcia Pinheiro

    2015-01-01

    In this paper, we discuss three translation techniques: literal, cultural, and artistic. Literal translation is a well-known technique, which means that it is quite easy to find sources on the topic. Cultural and artistic translation may be new terms. Whilst cultural translation focuses on matching contexts, artistic translation focuses on matching reactions. Because literal translation matches only words, it is not hard to find situations in which we should not use this technique.  Because a...

  12. Preliminary studies on the closed cycle magneto aerodynamic converter; Etudes preliminaires sur les convertisseurs magnetohydrodynamiques fonctionnant hors d'equilibre thermodynamique

    Energy Technology Data Exchange (ETDEWEB)

    Ricateau, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    electron heating in argon-potassium can be achieved by magnetic fields from 1 to 2 Ts. Plans are being made to build an important facility which will work on the principle of hot shots. The gas generator will deliver cesium-seeded helium shots at a temperature of 2100 deg. K. The shot will last 1/ 10 s and the instantaneous thermal power will reach 1 MW. (author) [French] A cote des convertisseurs magnetoaerodynamiques a cycle ouvert qui transforment l'energie thermique contenue dans les gaz de combustion on etudie tres attentivement le convertisseur a cycle ferme qui peut tirer son energie de toute source de chaleur a haute temperature et tout particulierement des sources nucleaires. Avant une etude pratique de l'ensemble de la centrale les performances du convertisseur lui-meme doivent etre bien delimitees. Ces performances sont largement fonction de la conductivite du gaz utilise. Mais cette conductivite ne doit pas etre payee par une temperature techniquement inadmissible pour l'echangeur de chaleur. Dans le fluide de conversion on est amene a associer un gaz porteur, helium ou argon, et une semence facilement ionisable cesium ou potassium. L'ionisation purement thermique n'est efficace qu'a partir de 2500 deg. K, par contre le champ electrique developpe par induction dans le convertisseur peut, sous certaines conditions, accroitre la temperature electronique et developper une ionisation bien superieure a la valeur d'equilibre. Il devient alors possible d'ioniser le gaz a temperature moderee. Des travaux en cours ont pour but de preciser les conditions permettant de creer cette ionisation hors d'equilibre dans les gaz rares ensemenses. Des mesures ont ete faites a l'aide d'un plasmatron triphase do 500 kVA alimente a l'argon ensemence de potassium. On a fait debiter cet appareil dans une cellule permettant de mesurer les composantes tensorielles de la conductivite en presence de champ magnetique. Les valeurs trouvees dans les conditions d'equilibre thermodynamique

  13. Study: control of atomic energy power plant; Etude de la regulation d'une installation atomique productrice d'energie

    Energy Technology Data Exchange (ETDEWEB)

    Dautray, R; Leny, J C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    We are studying the control of a very flexible atomic power plant, able to supply an independent network. Two systems have been examined: in the first the moderator pre-heats the light water, in the second, this preheating is dispensed with, subsequent to a study of the dynamics of the plant. Very complete linear approximation study is being effected on the model of the second system, all effects being taken into account. The reactor is stable at all power levels, though slight reactivity or load variations cause undamped power oscillations around the equilibrium level. (author)Fren. [French] Nous etudions la regulation d'une installation atomique d'une grande souplesse, pouvant eventuellement fournir de l'energie a un reseau isole. Deux versions de l'installation sont etudiees: dans la premiere le moderateur sert a rechauffer l'eau industrielle, mais l'etude dynamique conduit a supprimer ce rechauffage, ce qui donne la deuxieme version. On effectue sur celle-ci une etude en approximation lineaire tres complete ou l'on tient compte de differents effets. L'installation se montre stable a tous les niveaux de puissance. Toutefois, de petites perturbations de reactivite ou de charge entrainent des oscillations de puissance mal amorties autour de la position d'equilibre. (auteur)

  14. Mass spectrometric protein characterization in proteome analysis using GELoader tip micro-columns packed with various chromatographic material

    International Nuclear Information System (INIS)

    Larsen, M.R.

    2001-01-01

    In the early 90'ies mass spectrometry (MS) was introduced as a tool for identifying proteins in protein sequence databases. Since then it has become an integrated tool in protein characterization and is today routinely used to identify proteins separated by gel electrophoresis. A two-tiered mass spectrometric protein identification strategy has recently been proposed. In the first strategy peptide mass maps obtained from the protein of interest are compared with theoretically derived peptide mass maps from proteins in protein sequence databases. If the protein cannot be identified by this strategy, tandem mass spectrometric sequencing is used to generate enough sequence data to identify the protein in protein sequence databases or expressed sequence tag (EST) databases. However, the above strategies primarily identify a protein relatively to the DNA sequence, in which no information about e.g. post-translational modifications (PTMs) is stored. PTMs are known to modify the function, location, solubility and activity of proteins in the cell, and they are therefore very important for understanding living cells. More than 200 different PTMs are known, of which glycosylation, phosphorylation and proteolytic processing are the most common ones. Mass spectrometric analysis of PTMs on gel-separated proteins requires a higher amount of protein than for identification only. In addition, higher sequence coverage from the peptide mass maps or pre-purification of the modified peptides prior to MS analysis, is necessary for detection of putative modified peptides. In this study a multi-tiered strategy, in which GELoader tip micro-columns packed with increasingly more hydrophobic chromatographic material are used in combination with mass spectrometry, is described. The ultimate aim was to gain increased sequence coverage from peptide mixtures derived from gel-separated proteins, in order to locate modified peptides. Graphite powder is described as an alternative to traditional

  15. PPO-ethanol system as wavelength shifter for the Cherenkov counting technique using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Takiue, M.; Fujii, H.; Ishikawa, H.

    1984-01-01

    2,5-diphenyloxazole (PPO) has been proposed as a wavelength shifter for Cherenkov counting. Since PPO is not incorporated with water, we have introduced the fluor into water in the form of micelle using a PPO-ethanol system. This technique makes it possible to obtain a high Cherenkov counting efficiency under stable sample conditions, attributed to the proper spectrometric features of the PPO. The 32 P Cherenkov counting efficiency (68.4%) obtained from this technique is 1.62 times as large as that measured with a conventional Cherenkov technique. (orig.)

  16. Main results obtained in France in the development of the gaseous diffusion process for uranium isotope separation; Principaux resultats obtenus en France dans les etudes sur la separation des isotopes de l'uranium par diffusion gazeuse

    Energy Technology Data Exchange (ETDEWEB)

    Frejacques, C; Bilous, O; Dixmier, J; Massignon, D; Plurien, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The main problems which occur in the study of uranium isotope separation by the gaseous diffusion process, concern the development of the porous barrier, the corrosive nature of uranium hexafluoride and also the chemical engineering problems related to process design and the choice of best plant and stage characteristics. Porous barriers may be obtained by chemical attack of non porous media or by agglomeration of very fine powders. Examples of these two types of barriers are given. A whole set of measurement techniques were developed for barrier structure studies, to provide control and guidance of barrier production methods. Uranium hexafluoride reactivity and corrosive properties are the source of many difficult technological problems. A high degree of plant leak tightness must be achieved. This necessity creates a special problem in compressor bearing design. Barrier lifetime is affected by the corrosive properties of the gas, which may lead to a change of barrier structure with time. Barrier hexafluoride permeability measurements have helped to make a systematic study of this point. Finally an example of a plant flowsheet, showing stage types and arrangements and based on a minimisation of enriched product costs is also given as an illustration of some of the chemical engineering problems present. (author) [French] Les principaux problemes qui se sont poses dans l'etude de la separation des isotopes de l'uranium par diffusion gazeuse, sont ceux relatifs a l'obtention de barrieres poreuses, ceux lies a l'utilisation de l'hexafluorure d'uranium, enfin les problemes de genie chimique relatifs au procede et a l'agencement optimum des etages et des cascades entre elles. On peut obtenir des barrieres poreuses soit par attaque de membranes pleines, soit par agglomeration de poudres de petites dimensions. Des exemples de ces deux types de barrieres seront donnes. L'etude des proprietes de texture des barrieres obtenues, necessaire pour orienter les recherches de

  17. Thermoionic emission characteristics of uranium with application to its determination by MSID technique using 233U tracer

    International Nuclear Information System (INIS)

    Shihomatsu, H.M.; Iyer, S.S.

    1988-01-01

    Experimental details of the uranium determination in geological samples (50-1500 ppm range) by mass spectrometric isotope dilution technique (MSID) employing 233 U tracer are presented. For this purpose the thermoionic emission characteristics of uranium in various filament arrangements like simple plane, filament boat, double, are studied and the most efficient one selected for the isotope dilution analysis. The various experimental procedures involved in the MSID like sample dissolution, chemical separation and mass spectrometric analysis are developed and optimised. The experimental results on the uranium determination by MSID with 233 U tracer yielded precision and accuracy of 0,5% and 1% respectively. The importance of the sampling in the precise and accuracy determination of uranium in geological samples, where it is heterogeneously distributed, is discussed. (author) [pt

  18. Application of the mass spectrometry-isotope dilution technique for the determination of uranium contents in rocks

    International Nuclear Information System (INIS)

    Kakazu, M.H.; Iyer, S.S.

    1980-01-01

    Application of the spectrometric isotope dilution technique for the accurate determination of parts per million range of uranium in rock samples is described. The various aspects of the method like sample dissolution, ion exchange separation, mass spectrometric procedures are discussed. A single filament ionization source was employed for the isotope analysis. A carbon reduction method was used to reduce uranium oxide ions to uranium metal ions. The tracer solution for isotope dilution was prepared from National Bureau of Standards uranium isotopic Standard NBS U-970. Uranium contents are meassured for nine rock samples and the values obtained are compared with the uranium values measured by others workers. Errors caused in the uranium determination due to sample splitting problems as well as the incomplete acid digestion of the samples are discussed. (Author) [pt

  19. Identification of organic iodocompounds in the PUREX process with the help of methods for chromatographic separation and spectrometric detection as well as characterization of their behavior during extraction. Final report

    International Nuclear Information System (INIS)

    Gaul, G.; Gibau, F.; Knoechel, A.

    1993-01-01

    In the system HNO 3 KI, Dodecan and TBP the radiolytic reactive behaviour of the described compounds during the dissolution of nuclear fuel elements was simulated. External γ-irradiation gave the best informations. As a consequence of radiolyticly induced reactions several volatile and non-volatile iodoorganic compounds like iodoalkanes, iodonitroalkanes and iodonitroalkylphosphates are formed. They were separated by gaschromatography (GC) and high performance liquid chromatography (HPLC). For HPLC a special photolytic/electrochemical detector with comparable sensitivity like the electroncapture detector in the GC-field was developed. With the help of the two described chromatographic techniques the different iodoorganic compounds could be separated singularily or in groups of isomers. The separation of all compounds demands two-dimensional chromatographies including the capillary-SFC, which was not available for this project. Most of the iodoorganic compounds could be identified by comparison of the retention times of well known compounds. In the other cases, the compounds were studied mass-spectrometrically. Unfortunately all available ionisation techniques (EI; CI; FAB) were too hard for the labile C-I-bond. Therefore an identification of these compounds was not possible. In any case, instructive fingerprint spectra are available enabling relationships between the generation of the iodoorganic compounds and the reaction conditions during their formation. (orig.) [de

  20. Contribution to the crystallographic study of the uranium-oxygenated system; Contribution a l'etude cristallographique du systeme uranium-oxygene

    Energy Technology Data Exchange (ETDEWEB)

    Perio, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-04-15

    Three uranium oxides, UO{sub 2}, U{sub 3}O{sub 8} and UO{sub 3} are known since a long time. The existence of a fourth, U{sub 2}O{sub 5}, is discussed. The mechanisms of decomposition between UO{sub 3} and U{sub 3}O{sub 8} have even some shadow zones. The aim of this report is the study of the phase relations in an uranium - oxygen system, from the metal until UO{sub 3}. We considered, on the one hand, the equilibrium relations, what should result in a diagram of phases in pressures and temperatures, on the other hand, the transformations bringing one oxide to the other, often by a continuous way and through intermediate of metastable phases. The introduction of the temperature and the consideration of the kinetics effects have permitted to raise the ambiguities. We adopted, to facilitate the presentation of the results, a partition a few arbitrary but convenient, in three chapters,: I - experimental Techniques II - Crystallographic species between U and UO{sub 3}. III - Kinetic of oxidisation of UO{sub 2}. (M.B.) [French] Trois oxydes d'uranium, UO{sub 2}, U{sub 3}O{sub 8} et UO{sub 3} sont connus depuis longtemps. L'existence d'un quatrieme, U{sub 2}O{sub 5}, est en suspend. Les mecanismes de decomposition entre UO{sub 3} et U{sub 3}O{sub 8} possedent encore quelques zones d mbres. Le but propose dans ce memoire est l'etude des relations de phase dans le systeme uranium - oxygene, du metal jusqu'a UO{sub 3}. Nous avons ete amene a considerer, d'une part, les relations a l'equilibre, ce qui devrait se traduire par un diagramme de phases en pressions et temperatures, d'autre part, les transformations amenant, souvent d'une facon continue et par l'intermediaire de phases metastables, d'un oxyde a l'autre. L'introduction de la temperature et la consideration des effets de cinetique ont le plus souvent permis de lever les ambiguites rencontrees. Nous avons adopte, pour faciliter la presentation des resultats, une division un peu arbitraire mais commode, en trois

  1. Contribution to the study of french pitchblendes; Contribution a l'etude des pechblendes francaises

    Energy Technology Data Exchange (ETDEWEB)

    Geffroy, J. [Commissariat a l' Energie Atomique, Lab. de Mineralogie, Centre de Chatillon (France). Centre d' Etudes Nucleaires; Sarcia, J.A. [Commissariat a l' Energie Atomique, Div. de la Crouzille, Haute Vienne (France). Centre d' Etudes Nucleaires

    1955-07-01

    The authors first review the characteristics of uraninite-pitchblende, as deduced of present literature. They set apart from typical pitchblende a black oxide aspect, which probably corresponds to neo-formations, and a 'para-pitchblende' aspect, which they relate to deep sur-oxidation of normal pitchblende. They insist on the easy replacement of pitchblende by silica. and give indications as to changes in vein stones (fluorite, quartz, etc...). A detailed study of paragenesis and successions in french uranium districts follows (including discussion of uranium of uranium-bearing coals). The authors attempt to classify french pitchblende veins. They are chiefly epithermal and poor in satellite ores. Three types of deposits are identified: massive - pitchblende type, silica type, fluorite type. These deposits, as those of Portugal, are included in granite, Central-European peri-batholitic types where uranium associates which Ni, Co, Bi and Ag, are in France both rare and poor. Finally, the authors attempt to bring out in the european Hercynian area a particular distribution of paragenetic types. (authors) [French] Les auteurs recapitulent d'abord les caracteres et les occurences de l'uraninite - pechblende, tels qu'ils peuvent etre degages de l'actuelle bibliographie. Ils exposent ensuite les faits qui du point de vue mineralogique seulement ressortent de l'etude mineralogique et chalcographique des pechblendes francaises et de leurs satellites. Ils distinguent de la pechblende-type un facies oxyde noir; correspondant probablement a une neoformation, et un facies parapechblende, qui est rapporte a une sur oxydation hypogene de la pechblende proprement dite. Ils insistent sur le facile remaniement de la pechblende par la slice; et donnent quelques precisions sur les modifications des gangues (fluorine, quartz, etc...). Suit l'etude detaillee des parageneses et des successions dans les districts uraniferes francais: Divisions du

  2. Multi-element determination in environmental samples by mass spectrometric isotope dilution analysis using thermal ionization. Pt. 2

    International Nuclear Information System (INIS)

    Hilpert, K.; Waidmann, E.

    1988-01-01

    An analytical procedure for the multi-element analysis of the elements Fe, Ni, Cu, Zn, Ga, Rb, Sr, Cd, Ba, Tl, and Pb in pine needles by mass spectrometric isotope dilution analysis using thermal ionization has been reported in Part I of this paper. This procedure is now transferred to the non-vegetable material 'Oyster Tissue' (Standard Reference Material 1566, National Bureau of Standards, USA). By a modification of the analytical procedure, it was possible to determine Cr in this material in addition to the aforementioned elements. No concentrations are certified for the elements Ga, Ba and Tl analyzed in this work. The concentrations of the remaining elements obtained by the multi-element analysis agree well with those certified. (orig.)

  3. Gamma-spectrometric and total alpha-beta counting methods for radioactivity analysis of deuterium depleted water

    International Nuclear Information System (INIS)

    Ferdes, Ov. S.; Mladin, C.; Vladu, Mihaela; Bulubasa, G.; Bidica, N.

    2008-01-01

    According to national regulations, as well as to the EU directive on the quality of drinking water, the radionuclide concentrations represent some of the drinking water quality parameters. Among the most important radioactivity content parameters are: the total alpha and total beta concentration (Bq/l); K-40 content, and the gamma-nuclides volume activities. The paper presents the measuring methods for low-level total alpha and/or beta counting of volume samples, as well as the high-resolution gamma-ray spectrometric method used to measure the volume activity of nuclides in drinking water. These methods are applied to monitor the radioactivity content and quality of the QLARIVIA brand of Deuterium depleted water (DDW). There are discussed the performances of these applied methods as well as some preliminary results. (authors)

  4. Standard test methods for chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade plutonium dioxide powders and pellets

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade plutonium dioxide powders and pellets to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Plutonium Sample Handling 8 to 10 Plutonium by Controlled-Potential Coulometry Plutonium by Ceric Sulfate Titration Plutonium by Amperometric Titration with Iron(II) Plutonium by Diode Array Spectrophotometry Nitrogen by Distillation Spectrophotometry Using Nessler Reagent 11 to 18 Carbon (Total) by Direct Combustion–Thermal Conductivity 19 to 30 Total Chlorine and Fluorine by Pyrohydrolysis 31 to 38 Sulfur by Distillation Spectrophotometry 39 to 47 Plutonium Isotopic Analysis by Mass Spectrometry Rare Earth Elements by Spectroscopy 48 to 55 Trace Elements by Carrier–Distillation Spectroscopy 56 to 63 Impurities by ICP-AES Impurity Elements by Spark-Source Mass Spectrography 64 to 70 Moisture by the Coulomet...

  5. A Double Slow Neutron Spectrometer; Spectrometre double pour neutrons lents; Dvojnoj spektrometr medlennykh nejtronov; Espectrometro doble para neutrones lentos

    Energy Technology Data Exchange (ETDEWEB)

    Bondarenko, I I; Liforov, V G; Nikolaev, M N; Orlov, V V; Parfenov, V A; Semenov, V A; Smirnov, V I; Turchin, V F [Fehi, Moscow, SSSR (Russian Federation)

    1963-01-15

    The neutron spectrometer described in the paper is intended for measurements of the angular and energy distribution of monochromatic slow neutrons, inelasticaily scattered by liquid and solid bodies. Experiments of this type permit detailed information to be obtained concerning the dynamics of the atoms in various aggregate states of a substance. The spectromeeter is based on the time-of-flight method. The pulse source of neutrons is the IBR (1) reactor. A mechanical interrupter, rotating synchronously with the disc of the IBR and having a prescribed phase shift, serves as the monochromator. A special phasing system ensures a phasee stability better than 0.5{sup o}. The neutrons scattered by the sample are recorded by a scintillation detector set at a given angle to the neutron beam. The resolving power of the spectrometer is - 15 {mu}s/m. The paper gives a detailed description of the construction of the spectroscope and its characteristics. (author) [French] Le spectrometre neutronique decrit dans le memoire est destine a mesurer la distribution en energie, la distribution angulaire et la diffusion inelastique des neutrons lents monochromatiques dans des liquides et des solides. Les experiences de ce genre permettent d'obtenir des renseignements detailles sur la dynamique des atomes dans de divers etats de la matiere. Le spectrometre est fonde sur la mesure du temps de vol. Comme source puisee de neutrons on a utilise le reacteur IBR-1. Le systeme monochromateur etait constitue par un interrupteur mecanique en rotation synchronisee avec celle du disque du reacteur IBR, avec un dephasage determine. Un dispositif special de dephasage assure la stabilite de la phase a 0,5{sup o} pres. La diffusion des neutrons par l'echantillon est enregistree a l'aide d'un detecteur a scintillations dispose sous un angle determine par rapport au faisceau de neutrons. Le pouvoir de resolution du spectrometre est d'environ 15 {mu}s/m. Les auteurs decrivent en detail la construction du

  6. Development of a mass spectrometrical isotope dilution analysis for determination of trace iodine levels and its application for food samples

    International Nuclear Information System (INIS)

    Schindlmeier, W.

    1984-01-01

    A mass spectrometrical isotope dilution procedure for the determination of trace amounts of iodine in various materials was developed using 129 I as indicator isotope, based on the determination of the 129 I/ 127 I isotope relationship. Negative thermionization was used as ionization method. The analysis procedure, which worked with a standard deviation of between 0,1 and 10% (depending on material tested), was used to determine the iodine level of table salt - both iodized and normal salt (3-6 ppm and less than 0,006 ppm respectively), and food samples with an organic matrix. For comparison the iodine levels were also measured with an iodine-selective electrode. Special preparation and separation procedures were done to suit the sample material. A comparison of the levels of iodine concentration in various powdered milks which were measured by international collaborators using varying methods shows the superior reproducibility of the MS-IDA. (RB) [de

  7. Rational utilisation of a spectrometer detector for leaks; Utilisation rationnelle d'un spectrometre detecteur de fuites

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1954-07-01

    In this following article, we expose the general problem of the leakage in a vacuum installation. We consider the principles of the detection in general and study especially the conditions of detection by an helium spectrometer. We deduce practical conclusions as for the branching of this last and to its application in the most current cases. (author) [French] Dans l'article qui suit, nous exposons le probleme general des fuites dans une installation a vide. Nous y envisageons les principes de la detection en general et etudions particulierement les conditions de detection par spectrometre a helium. Noue tirons des conclusions pratiques quant au branchement de ce dernier et a son application dans les cas les plus courants. (auteur)

  8. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade uranyl nitrate solutions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade uranyl nitrate solution to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Determination of Uranium 7 Specific Gravity by Pycnometry 15-20 Free Acid by Oxalate Complexation 21-27 Determination of Thorium 28 Determination of Chromium 29 Determination of Molybdenum 30 Halogens Separation by Steam Distillation 31-35 Fluoride by Specific Ion Electrode 36-42 Halogen Distillate Analysis: Chloride, Bromide, and Iodide by Amperometric Microtitrimetry 43 Determination of Chloride and Bromide 44 Determination of Sulfur by X-Ray Fluorescence 45 Sulfate Sulfur by (Photometric) Turbidimetry 46 Phosphorus by the Molybdenum Blue (Photometric) Method 54-61 Silicon by the Molybdenum Blue (Photometric) Method 62-69 Carbon by Persulfate Oxidation-Acid Titrimetry 70 Conversion to U3O8 71-74 Boron by ...

  9. Standard test methods for chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 These test methods cover procedures for the chemical, mass spectrometric, spectrochemical, nuclear, and radiochemical analysis of nuclear-grade plutonium nitrate solutions to determine compliance with specifications. 1.2 The analytical procedures appear in the following order: Sections Plutonium by Controlled-Potential Coulometry Plutonium by Amperometric Titration with Iron(II) Plutonium by Diode Array Spectrophotometry Free Acid by Titration in an Oxalate Solution 8 to 15 Free Acid by Iodate Precipitation-Potentiometric Titration Test Method 16 to 22 Uranium by Arsenazo I Spectrophotometric Test Method 23 to 33 Thorium by Thorin Spectrophotometric Test Method 34 to 42 Iron by 1,10-Phenanthroline Spectrophotometric Test Method 43 to 50 Impurities by ICP-AES Chloride by Thiocyanate Spectrophotometric Test Method 51 to 58 Fluoride by Distillation-Spectrophotometric Test Method 59 to 66 Sulfate by Barium Sulfate Turbidimetric Test Method 67 to 74 Isotopic Composition by Mass Spectrom...

  10. Study of the fluctuations of the partial and total radiative widths by neutron capture resonance method; Etude des fluctuations des largeurs radiatives partielles et totales par la capture des neutrons de resonance

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, V D [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    Radiative capture experiments by neutron time-of-flight methods have been made for following studies: distribution of partial radiative widths, effects of correlation between different radiative transitions, fluctuations of total radiative widths {gamma}{sub {gamma}} from resonance to resonance, variation of {gamma}{sub {gamma}} with number of mass and the search for the existence of potential capture. Also, some other experiments with the use of neutron capture gamma-rays spectra have been investigated. (author) [French] Par la capture des neutrons de resonance dont les energies sont selectionnees a l'aide de la technique du temps de vol, differents types d'experiences ont ete realisees concernant les etudes des distributions des largeurs radiatives partielles, des effets de correlation entre differentes voies de desexcitation, de la fluctuation des largeurs radiatives totales {gamma}{sub {gamma}} de resonance a resonance, de la variation de la quantite {gamma}{sub {gamma}} en fonction du nombre de masse et de la mise en evidence de l'existence du processus de capture potentielle. Quelques autres applications de l'emploi du spectre de rayons gamma ont egalement ete presentees. (auteur)

  11. Study of the fluctuations of the partial and total radiative widths by neutron capture resonance method; Etude des fluctuations des largeurs radiatives partielles et totales par la capture des neutrons de resonance

    Energy Technology Data Exchange (ETDEWEB)

    Huynh, V.D. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-06-01

    Radiative capture experiments by neutron time-of-flight methods have been made for following studies: distribution of partial radiative widths, effects of correlation between different radiative transitions, fluctuations of total radiative widths {gamma}{sub {gamma}} from resonance to resonance, variation of {gamma}{sub {gamma}} with number of mass and the search for the existence of potential capture. Also, some other experiments with the use of neutron capture gamma-rays spectra have been investigated. (author) [French] Par la capture des neutrons de resonance dont les energies sont selectionnees a l'aide de la technique du temps de vol, differents types d'experiences ont ete realisees concernant les etudes des distributions des largeurs radiatives partielles, des effets de correlation entre differentes voies de desexcitation, de la fluctuation des largeurs radiatives totales {gamma}{sub {gamma}} de resonance a resonance, de la variation de la quantite {gamma}{sub {gamma}} en fonction du nombre de masse et de la mise en evidence de l'existence du processus de capture potentielle. Quelques autres applications de l'emploi du spectre de rayons gamma ont egalement ete presentees. (auteur)

  12. Processing of data issued from a {gamma} spectrometer; Traitement des informations issues d'un spectrometre {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Boulanger, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-03-01

    The purpose of the following report is the study of computation method applied to analysis by gamma spectrometry. We first study quantitative analysis by the least-squares method, improved by a gain-shift correction. Then the single full-energy peaks and the resolution of complex peaks are dealt with. In both cases, the calculation principle, then the systematic tests achieved in order to-prove their validity and determine their application ranges are described and finally some experimental results appropriate to illustrate their possibilities are presented. (author) [French] Le present rapport a pour objet l'etude de methodes de calcul applicables a l'analyse par spectrometrie gamma. On etudie d'abord l'analyse quantitative par la methode des moindres carres, completee par une correction de derive du gain. Puis on examine les pics d'absorption totale simples et la resolution des pics complexes. Dans les deux cas, on expose le principe des calculs et les essais systematiques effectues pour eprouver leur validite et definir leurs domaines d'application, ainsi que quelques resultats experimentaux propres a illustrer leurs possibilites.

  13. The dynamic behaviour of heat exchangers; Etude du comportement dynamique des echangeurs de chaleur

    Energy Technology Data Exchange (ETDEWEB)

    Fonteray, J; Rozenholc, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    In order to study the dynamics of nuclear power plants, one needs mathematical models made up of ordinary differential equations. This report deals with models for heat exchangers. These models allow exact evaluations of the temperatures for any steady state. The deformation of the temperature maps during transients is taken into account. To do this, average temperatures are evaluated keeping In mind, on one hand the partial differential equations, on the other hand, the physical phenomenons which are involved. Seven ordinary differential equations at most, are necessary for one heat exchanger. Theses models were compared with mathematically exact ones and also with experimental results, that EDF was able to measure on EDF-1 heat exchangers. The results appear to be correct. (authors) [French] Les etudes de dynamique sur les centrales nucleaires exigent l'elaboration de modeles apparaissant sous forme d'equations differentlelles ordinaires. Ce rapport est consacre a la recherche de modeles d'echangeurs. Dans ces modeles les temperatures sont calculees exactement pour n'importe quel regime permanent. Pour tenir compte de la deformation des distributions de temperature en regime transitoire, on evalue les temperatures moyennes dans l'echangeur en s'appuyant, d'une part, sur les equations aux derivees partielles et, d'autre part, sur une analyse des phenomenes physiques. Les modeles contiennent au plus sept equations differentielles ordinaires. Ces modeles ont ete compares aux modeles mathematiques exacts et aussi a des resultats experimentaux, obtenus par l'EDF, sur les echangeurs d'EDF-1. Les resultats paraissent satisfaisants. (auteurs)

  14. Mass spectrometric identification of proteins that interact through specific domains of the poly(A) binding protein.

    Science.gov (United States)

    Richardson, Roy; Denis, Clyde L; Zhang, Chongxu; Nielsen, Maria E O; Chiang, Yueh-Chin; Kierkegaard, Morten; Wang, Xin; Lee, Darren J; Andersen, Jens S; Yao, Gang

    2012-09-01

    Poly(A) binding protein (PAB1) is involved in a number of RNA metabolic functions in eukaryotic cells and correspondingly is suggested to associate with a number of proteins. We have used mass spectrometric analysis to identify 55 non-ribosomal proteins that specifically interact with PAB1 from Saccharomyces cerevisiae. Because many of these factors may associate only indirectly with PAB1 by being components of the PAB1-mRNP structure, we additionally conducted mass spectrometric analyses on seven metabolically defined PAB1 deletion derivatives to delimit the interactions between these proteins and PAB1. These latter analyses identified 13 proteins whose associations with PAB1 were reduced by deleting one or another of PAB1's defined domains. Included in this list of 13 proteins were the translation initiation factors eIF4G1 and eIF4G2, translation termination factor eRF3, and PBP2, all of whose previously known direct interactions with specific PAB1 domains were either confirmed, delimited, or extended. The remaining nine proteins that interacted through a specific PAB1 domain were CBF5, SLF1, UPF1, CBC1, SSD1, NOP77, yGR250c, NAB6, and GBP2. In further study, UPF1, involved in nonsense-mediated decay, was confirmed to interact with PAB1 through the RRM1 domain. We additionally established that while the RRM1 domain of PAB1 was required for UPF1-induced acceleration of deadenylation during nonsense-mediated decay, it was not required for the more critical step of acceleration of mRNA decapping. These results begin to identify the proteins most likely to interact with PAB1 and the domains of PAB1 through which these contacts are made.

  15. Etude theorique et experimentale des evaporateurs de dioxyde de carbone operant dans des conditions de givrage

    Science.gov (United States)

    Bendaoud, Adlane Larbi

    Les evaporateurs de refrigeration sont surtout du type tube a ailettes, appeles serpentins, et fonctionnent dans l'une des conditions suivantes: seche, humide ou avec formation de givre. Il a ete demontre que la formation du givre sur la paroi exterieure de l'echangeur engendre une surconsommation energetique a cause des operations de degivrage puisque 15 a 20% seulement de la chaleur produite sert au degivrage tandis que le reste est dissipee dans l'environnement [1]. Avec l'avenement des nouveaux refrigerants, moins nocifs envers l'environnement, l'industrie du froid se trouve penalisee du fait que peu ou pas de composantes mecaniques (compresseur, pompe, echangeur...etc.) adaptees sont disponibles [3]. Il s'agit pour la communaute des frigoristes de combler ce retard technologique en redeveloppant ces composantes mecaniques afin qu'elles soient adaptees aux nouveaux refrigerants. Dans cette optique, et afin de mieux comprendre le comportement thermique des evaporateurs au CO2 fonctionnant dans des conditions seches, qu'un groupe de chercheurs du CanmetENERGIE avaient lance, en 2000, un programme de R & D. Dans le cadre de programme un outil de simulation des evaporateurs au CO2 a ete developpe et un banc d'essai contenant une boucle secondaire de refrigeration utilisant le CO2 comme refrigerant a ete construit. Comme continuite de ce travail de recherche, en 2006 ce meme groupe de recherche a lance un nouveau projet qui consiste a faire une etude theorique et experimentale des evaporateurs au CO2 operants dans des conditions de givrage. Et, c'est exactement dans le cadre de ce projet que se positionne ce travail de these. Ce travail de recherche a ete entrepris pour mieux comprendre le comportement thermique et hydrodynamique des serpentins fonctionnant dans des conditions de givrage, l'effet des circuits de refrigerant ainsi que celui des parametres geometriques et d'operation. Pour cela, un travail theorique supporte par une etude experimentale a ete effectue

  16. An approach to automated chromosome analysis; Etudes pour une methode d'automatisation des analyses chromosomiques

    Energy Technology Data Exchange (ETDEWEB)

    Le Go, Roland

    1972-05-03

    d'une automatisation des differentes etapes de l'analyse chromosomique. Il est divise en trois tomes dont la matiere est decrite ci-apres. Dans le tome 1 est decrite l'etude d'un selecteur automatique de metaphases. Cet appareil doit realiser au cours du scanning d'une preparation, un processus de decision aboutissant a rejeter toutes images ininteressantes et a conserver les images pertinentes (bonnes metaphases). Ce probleme a ete aborde au moyen d'une etude sur ordinateur par un programme de simulation. La realisation de ce programme a permis d'etablir des algorithmes de selection dont la replique pourra etre realisee dans des circuits logiques electroniques. Dans le tome 2 est traite le probleme de l'automatisation de l'etude morphologique des chromosomes presents dans une metaphase. Cette automatisation necessite le traitement des photographies de metaphases par un appareil convertisseur optique-numerique qui extrait l'information-image et la transcrit sous la forme d'un fichier numerique. Ce fichier comporte pour une image de metaphase, environ 200 000 valeurs de gris, codees selon une echelle a 16, 32 ou 64 ni veaux. Ce fichier numerique est traite par un programme de reconnaissance de forme, qui isole les chromosomes et en recherche les traits caracteristiques: sommets de bras et region centromerique, dans le but d'obtenir des mensurations equivalentes aux longueurs des quatre bras. Le tome 3 etudie un programme d'etablissement automatique du caryotype humain, par appariement optimise des chromosomes. Les donnees proviennent de la numerisation directe des longueurs de bras, effectuee au moyen d'un lecteur digital BENSON. Le programme etablit une liste des appariements, un document graphique imprime representant les paires constituees, dans l'espace: longueur - index centromerique; enfin un document graphique obtenu sur traceur BENSON dans lequel l'auteur donne une representation personnelle des chromosomes, sous forme de croix a bras orthogonaux, dont chaque

  17. Pegase: safety studies - experimental study of burn-out risks in transient operation; Pegase: etude de surete - etude experimentale des risques de burn out en regime transitoire

    Energy Technology Data Exchange (ETDEWEB)

    Vernier, P [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1968-07-01

    canal chaud se met en etat de calefaction au bout de 0.1 s et que sa temperature atteint 500 C en 0.8 s. Les regimes hydrodynamiques rencontres dans les canaux apres l'accident sont des regimes d'expulsion periodiques de periodes courtes 0.2 a 0.5 s, caracteristiques de l'ebullition a basse pression. L'etude en regime permanent de la redistribution de debit dans un by-pass a donne des flux PHI{sub R} de redistribution de 190 W/cm{sup 2} pour une vitesse de 4.5 m/s a 50 C et de 175 W/cm{sup 2} a 60 C. Ces valeurs sont a majorer de 25 pour cent pour une vitesse de 6 m/s. On a montre la distinction a faire entre flux critique PHI{sub C} en regime periodique d'expulsion et flux de redistribution PHI{sub R} en regime permanent. (auteur)

  18. Diagnostic techniques

    International Nuclear Information System (INIS)

    Berquist, T.H.; Bender, C.E.; James, E.M.; Brown, M.L.; McLeod, R.A.; Broderick, D.F.; Welch, T.J.

    1989-01-01

    Proper application of imaging procedures is essential to obtain needed information for diagnosis and therapy planning in patients with suspected foot and/or ankle pathology. This paper provides basic background data for the numerous imaging techniques

  19. Study of the dynamic behaviour of the reactor Rapsodie; Etude du comportement dynamique de la pile rapsodie

    Energy Technology Data Exchange (ETDEWEB)

    Abdon, R; Chaigne, M [Commissariat a l' Energie Atomique, Cadarache (France). Centre d' Etudes Nucleaires

    1964-07-01

    . The investigation of the control, carried out on analog computer, served to determine the different possible means of starting and changing the conditions of the reactor as well as its automatic control. The calculations were examined in the totality by the construction of a training simulator composed of a board similar to the control board of the reactor, all of whose commands (reactivity and flows) work on an analogue computer which resolves in the real time the dynamic equations of the reactor and which reproduces simultaneously all the parameters representing the state of the installation (power, period, temperatures, etc. ) in the case of various incidents as well as under normal conditions of functioning. (authors) [French] On sait que le developpement des reacteurs surgenerateurs a neutrons rapides pose des problemes nouveaux d'une part dans les domaines mecanique et thermique et d'autre part en ce qui concerne leur comportement dynamique et leur surete. La pile RAPSODIE a ete l'objet de tres nombreuses etudes dynamiques effectuees sur machines analogiques et digitales, pour deux versions du combustible (metal et oxyde). Apres elaboration des modeles mathematiques representatifs de l'ensemble de l'installation (bloc pile et circuit de refroidissement) tant du point de vue neutronique que du point de vue thermodynamique, on a mis au point les schemas analogiques et les codes digitaux utilisables pour mener a bien les simulations d'incidents, de conduite et de stabilite du reacteur. On s'est attache, par rapport aux methodes habituelles a obtenir une precision plus grande, par un decoupage en zones plus fines, par l'emploi de formulations plus representatives du systeme reel, voire solubles analytiquement. Les etudes d'incidents ont ete effectuees par voie analogique pour l'ensemble de l'installation et par voie digitale pour l'etude du bloc pile seul ou de l'installation fonctionnant avec un seul circuit thermique. Un programme complementaire special - qui, a

  20. Collision energy alteration during mass spectrometric acquisition is essential to ensure unbiased metabolomic analysis

    CSIR Research Space (South Africa)

    Madala, NE

    2012-08-01

    Full Text Available Metabolomics entails identification and quantification of all metabolites within a biological system with a given physiological status; as such, it should be unbiased. A variety of techniques are used to measure the metabolite content of living...

  1. Automated mass spectrometric analysis of urinary free catecholamines using on-line solid phase extraction

    NARCIS (Netherlands)

    de Jong, Wilhelmina H. A.; de Vries, Elisabeth G. E.; Wolffenbuttel, Bruce H. R.; Kema, I. P.

    2010-01-01

    Analysis of catecholamines (epinephrine, norepinephrine and dopamine) in plasma and urine is used for diagnosis and treatment of catecholamine-producing tumors Current analytical techniques for catecholamine quantification are laborious, time-consuming and technically demanding Our aim was to

  2. Reduction of beta-interference in gamma-spectrometric measurements of neutron-irradiated geological material

    International Nuclear Information System (INIS)

    Garmann, L.B.

    1986-01-01

    The analytical technique for INAA, when applied to geological materials, is improved by introducing an electromagnetic field between sample and detector. This field lowers the bremsstrahlung background intensity in the gamma-spectrum by reducing the number of beta-particles reaching the detector. Thus precision, accuracy and lower detection limit are improved. The technique was used on alkalisyenite and on meteoritic material, rocks containing high quantities of sodium and iron, respectively. After neutron irradiation, the induced nuclides sup(24)Na and sup(59)Fe are responsible for high bremsstrahlung interference, which under normal analyitical conditions would mask any x-ray or gamma-ray peaks of interest. The technique is easily applied to multielement analysis of geological and biological materials. It can be combined with sophisticated spectrum-treating techniques such as spectrum stripping and spectrum smoothing, or coincidence-anticoincidence circuits. (author)

  3. Airborne gamma spectrometric survey in the Chernobyl exclusion zone based on oktokopter UAV type

    International Nuclear Information System (INIS)

    Zabulonov, Yu.L.; Burtnyak, V.M.; Zolkin, I.O.

    2015-01-01

    The results of field studies of radioactive contamination condition of RWTSP ''Red Forest'' and ''Neftebaza'' in the Chernobyl zone, obtained by the authors in June 2015 are represented. The technique of detection of local inhomogeneities on the soil surface without contrasting borders by airborne gamma spectrometry from the board of oktokopter UAV type is worked through. The technique of searching and contouring of hidden burial of radioactive waste is practiced

  4. A rapid alpha spectrometric method for estimation of 233U in bulk of thorium

    International Nuclear Information System (INIS)

    Rao, K.S.; Sankar, R.; Dhami, P.S.; Tripathi, S.C.; Gandhi, P.M.

    2015-01-01

    Analytical methods play important role in entire nuclear fuel cycle. Almost all the methods find applications in some way or the other in nuclear industry. Methods which cannot be directly used owing to selectivity, find application after chemical separation of analyte from interfering components. The analytical techniques used in PUREX process are almost well matured whereas in THOREX process the analytical techniques are constantly evolving as regards to simplicity, accuracy and time of analysis

  5. Decomposition techniques

    Science.gov (United States)

    Chao, T.T.; Sanzolone, R.F.

    1992-01-01

    Sample decomposition is a fundamental and integral step in the procedure of geochemical analysis. It is often the limiting factor to sample throughput, especially with the recent application of the fast and modern multi-element measurement instrumentation. The complexity of geological materials makes it necessary to choose the sample decomposition technique that is compatible with the specific objective of the analysis. When selecting a decomposition technique, consideration should be given to the chemical and mineralogical characteristics of the sample, elements to be determined, precision and accuracy requirements, sample throughput, technical capability of personnel, and time constraints. This paper addresses these concerns and discusses the attributes and limitations of many techniques of sample decomposition along with examples of their application to geochemical analysis. The chemical properties of reagents as to their function as decomposition agents are also reviewed. The section on acid dissolution techniques addresses the various inorganic acids that are used individually or in combination in both open and closed systems. Fluxes used in sample fusion are discussed. The promising microwave-oven technology and the emerging field of automation are also examined. A section on applications highlights the use of decomposition techniques for the determination of Au, platinum group elements (PGEs), Hg, U, hydride-forming elements, rare earth elements (REEs), and multi-elements in geological materials. Partial dissolution techniques used for geochemical exploration which have been treated in detail elsewhere are not discussed here; nor are fire-assaying for noble metals and decomposition techniques for X-ray fluorescence or nuclear methods be discussed. ?? 1992.

  6. The study of neutron transport by oscillation method; Etude du transport des neutrons par la methode de modulation

    Energy Technology Data Exchange (ETDEWEB)

    Raievski, V

    1959-07-01

    The oscillation method is of very general use for studying the behavior of thermal neutrons in media. The main experiments are described and a general theory of them is given. This theory, which is presented in the first part, is established using the two-group approximation which has proved its efficiency in the case of thermal neutron piles. The validity of the two-group approximation is recalled. This allows definition of the meaning of the parameters used in the theory and which are measured in these experiments. The experiments carried out by this method are described, especially those performed at the Centre d'Etudes Nucleaires de Saclay where the method has been extensively used. These experiments are interpreted by means of the general theory given previously. In this way, the identity of parameters measured by this method and those given by the theory is proved. This is particularly conclusive is the case of the mean life of neutrons in a pile. (author) [French] La methode de modulation est un procede tres general d'etude des proprietes neutroniques des milieux contenant des neutrons thermiques. Le present rapport a pour but de decrire les principales de ces experiences et d'en donner une theorie generale. Cette theorie, exposee dans la premiere partie, est etablie dons le cadre de l'approximation a deux groupes de vitesse qui a prouve son efficacite dons le cas des piles a neutrons thermiques. Le domaine de validite de l'approximation a deux groupes est rappele au debut, ce qui permet de definir avec precision la signification des parametres qui entrent dons la theorie et qui font l'objet de ces mesures. La deuxieme partie decrit les experiences realisees, en particulier celles effectuees au Centre d'Etudes Nucleaires de Saclay ou la methode a ete considerablement developpee. Ces experiences sont interpretees dans le cadre de la theorie generale exposee precedemment. On prouve ainsi l'identite des parametres mesures par cette methode et de ceux figurant

  7. Acetylation and glycation of fibrinogen in vitro occur at specific lysine residues in a concentration dependent manner: A mass spectrometric and isotope labeling study

    International Nuclear Information System (INIS)

    Svensson, Jan; Bergman, Ann-Charlotte; Adamson, Ulf; Blombäck, Margareta; Wallén, Håkan; Jörneskog, Gun

    2012-01-01

    Highlights: ► Fibrinogen was incubated in vitro with glucose or aspirin. ► Acetylations and glycations were found at twelve lysine sites by mass spectrometry. ► The labeling by aspirin and glucose occurred dose-dependently. ► No competition between glucose and aspirin for binding to fibrinogen was found. -- Abstract: Aspirin may exert part of its antithrombotic effects through platelet-independent mechanisms. Diabetes is a condition in which the beneficial effects of aspirin are less prominent or absent – a phenomenon called “aspirin resistance”. We investigated whether acetylation and glycation occur at specific sites in fibrinogen and if competition between glucose and aspirin in binding to fibrinogen occurs. Our hypothesis was that such competition might be one explanation to “aspirin resistance” in diabetes. After incubation of fibrinogen in vitro with aspirin (0.8 mM, 24 h) or glucose (100 mM, 5–10 days), we found 12 modified sites with mass spectrometric techniques. Acetylations in the α-chain: αK191, αK208, αK224, αK429, αK457, αK539, αK562, in the β-chain: βK233, and in the γ-chain: γK170 and γK273. Glycations were found at βK133 and γK75, alternatively γK85. Notably, the lysine 539 is a site involved in FXIII-mediated cross-linking of fibrin. With isotope labeling in vitro, using [ 14 C-acetyl]salicylic acid and [ 14 C]glucose, a labeling of 0.013–0.084 and 0.12–0.5 mol of acetylated and glycated adduct/mol fibrinogen, respectively, was found for clinically (12.9–100 μM aspirin) and physiologically (2–8 mM glucose) relevant plasma concentrations. No competition between acetylation and glycation could be demonstrated. Thus, fibrinogen is acetylated at several lysine residues, some of which are involved in the cross-linking of fibrinogen. This may mechanistically explain why aspirin facilitates fibrin degradation. We find no support for the idea that glycation of fibrin(ogen) interferes with acetylation of

  8. Acetylation and glycation of fibrinogen in vitro occur at specific lysine residues in a concentration dependent manner: A mass spectrometric and isotope labeling study

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Jan, E-mail: jan.svensson@ki.se [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital (Solna), SE-171 76 Stockholm (Sweden); Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, SE-182 88 Stockholm (Sweden); Bergman, Ann-Charlotte [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital (Solna), SE-171 76 Stockholm (Sweden); Adamson, Ulf [Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, SE-182 88 Stockholm (Sweden); Blombaeck, Margareta [Department of Molecular Medicine and Surgery, Karolinska Institutet, Karolinska University Hospital (Solna), SE-171 76 Stockholm (Sweden); Wallen, Hakan; Joerneskog, Gun [Karolinska Institutet, Department of Clinical Sciences, Danderyd Hospital, SE-182 88 Stockholm (Sweden)

    2012-05-04

    Highlights: Black-Right-Pointing-Pointer Fibrinogen was incubated in vitro with glucose or aspirin. Black-Right-Pointing-Pointer Acetylations and glycations were found at twelve lysine sites by mass spectrometry. Black-Right-Pointing-Pointer The labeling by aspirin and glucose occurred dose-dependently. Black-Right-Pointing-Pointer No competition between glucose and aspirin for binding to fibrinogen was found. -- Abstract: Aspirin may exert part of its antithrombotic effects through platelet-independent mechanisms. Diabetes is a condition in which the beneficial effects of aspirin are less prominent or absent - a phenomenon called 'aspirin resistance'. We investigated whether acetylation and glycation occur at specific sites in fibrinogen and if competition between glucose and aspirin in binding to fibrinogen occurs. Our hypothesis was that such competition might be one explanation to 'aspirin resistance' in diabetes. After incubation of fibrinogen in vitro with aspirin (0.8 mM, 24 h) or glucose (100 mM, 5-10 days), we found 12 modified sites with mass spectrometric techniques. Acetylations in the {alpha}-chain: {alpha}K191, {alpha}K208, {alpha}K224, {alpha}K429, {alpha}K457, {alpha}K539, {alpha}K562, in the {beta}-chain: {beta}K233, and in the {gamma}-chain: {gamma}K170 and {gamma}K273. Glycations were found at {beta}K133 and {gamma}K75, alternatively {gamma}K85. Notably, the lysine 539 is a site involved in FXIII-mediated cross-linking of fibrin. With isotope labeling in vitro, using [{sup 14}C-acetyl]salicylic acid and [{sup 14}C]glucose, a labeling of 0.013-0.084 and 0.12-0.5 mol of acetylated and glycated adduct/mol fibrinogen, respectively, was found for clinically (12.9-100 {mu}M aspirin) and physiologically (2-8 mM glucose) relevant plasma concentrations. No competition between acetylation and glycation could be demonstrated. Thus, fibrinogen is acetylated at several lysine residues, some of which are involved in the cross-linking of

  9. Randomized control trial for the assessment of the anti-albuminuric effects of topiroxostat in hyperuricemic patients with diabetic nephropathy (the ETUDE study).

    Science.gov (United States)

    Kato, Sawako; Ando, Masahiko; Mizukoshi, Toshihiro; Nagata, Takanobu; Katsuno, Takayuki; Kosugi, Tomoki; Tsuboi, Naotake; Maruyama, Shoichi

    2016-05-01

    Proteinuria is an established risk factor for diabetic nephropathy. Recent studies indicate that some xanthine oxidase inhibitors have a renoprotective effect. The aim of this study was to assess whether topiroxostat reduces albuminuria in hyperuricemic patients with diabetic nephropathy and overt proteinuria. The ETUDE study is an ongoing 24-week, multicenter, open-label, randomized (1:1), parallel group study involving hyperuricemic patients with diabetic nephropathy (estimated glomerular filtration rate [eGFR] ≥ 20 mL/min/1.73 m(2)) and overt proteinuria (0.3 ≤ urine protein to creatinine ratio (UPCR) ETUDE trial is the first randomized controlled study of topiroxostat in hyperuricemic patients with diabetic nephropathy and overt proteinuria. We will clarify the pleiotropic function of topiroxostat including an anti-albumiuric effect as well as its effects on safely decreasing serum uric acid levels.

  10. Study and development of an optical method for the measurement of convection coefficients; Etude et developpement d'une methode optique pour la mesure du coefficient de convection

    Energy Technology Data Exchange (ETDEWEB)

    Crowther, David J.

    1990-03-06

    This research thesis addresses the field of fluid-wall thermal exchanges in which the notion of exchange coefficient is notably useful to design, size and optimise devices. A first part reports a bibliographical study which gives an overview of solutions envisaged to determine the convection coefficient in permanent regime with the use of flow sensors, as well as in transient regime. Then, the author reports the development of an unsteady method which is based on the analysis of the cooling kinetics of the front face of a convecting wall, after a unique energetic perturbation (an infinitely brief pulse, or a finite duration energy step). This method is applied to the general case (wall with finite thickness) and to the case of a semi-infinite wall which is typical of materials which are weak thermal conductors. This is extended to the case of good thermal conductors by considering a thermally thin wall. After a detailed description of the experimental bench, above-mentioned solutions are applied to insulating and good thermal conducting materials. In order to validate results of an analysis in transient regime, they are compared with measurements performed in permanent regime with a flow-metering technique. The study of the principle of the dissipation-based flow sensor, and its operation are reported. Experimental results are presented for both methods (pulse and flow sensor), and compared in order to highlight the interest of the unsteady method [French] Difficile a mesurer, le coefficient de convection reste cependant une grandeur necessaire au calcul et a l'optimisation de tout systeme thermique. L'amelioration des capteurs thermiques permet aujourd'hui de concevoir une methode optique, utilisable a distance, et non destructive. Nous proposons dans ce but, un procede de mesure en regime transitoire base sur la radiometrie photothermique impulsionnelle. L'analyse du regime de relaxation d'une paroi, apres une brusque elevation de temperature, permet de remonter

  11. Etude de la transition ferroelectrique-ferroelastique du KD2PO4 forme du front de phase en fonction du gradient thermique

    OpenAIRE

    Kvítek, Zdeněk

    2010-01-01

    Etude de la transition ferroelectrique-ferroelastique du KD2PO4 forme du front de phase en fonction du gradient thermique The thesis explores complex process of first order transition of KD2PO4 crystal from tetragonal phase to ferroelectric - ferroelastic orthorhombic phase and back at temperature 209 K. The experimental set up of nitrogeneous cryostat allowes temperature and temperature gradient variations during simultaneous three axes optical sample observations, dielectric measurements. T...

  12. Experimental study of contamination by inhalation of radioactive iodine aerosols. Biological balance; Etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif bilan biologique

    Energy Technology Data Exchange (ETDEWEB)

    Marble, G [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Several articles have been published concerning research into contamination produced by inhalation of radioactive iodine aerosols in monkeys. Results dealing with the biological balance of this contamination are presented and discussed in this report. (author) [French] L'etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif effectuee chez le singe a fait l'objet de plusieurs publications. Les resultats concernant le bilan biologique de cette contamination sont presentes et discutes dans ce rapport. (auteur)

  13. Matrix isolation-infrared and mass spectrometric studies of high-temperature molecules

    International Nuclear Information System (INIS)

    Dickinson, S.

    1987-08-01

    Matrix isolation-infrared spectroscopy and mass spectrometry have been developed at AEE Winfrith to study the high-temperature vapour species which could be generated during a hypothetical severe reactor accident. The principles of the techniques and the instruments are described in detail, and examples of their application to specific systems discussed. Although these examples refer to high-temperature chemical species which are relevant to reactor safety assessments, the techniques are equally applicable to other processes where the characterisation of transient vapour-phase species is required. (author)

  14. Neutron techniques

    International Nuclear Information System (INIS)

    Charlton, J.S.

    1986-01-01

    The way in which neutrons interact with matter such as slowing-down, diffusion, neutron absorption and moderation are described. The use of neutron techniques in industry, in moisture gages, level and interface measurements, the detection of blockages, boron analysis in ore feedstock and industrial radiography are discussed. (author)

  15. Studies of iron carbon alloys; Contribution a l'etude des alliages dilues de carbone dans le fer {alpha}

    Energy Technology Data Exchange (ETDEWEB)

    Anagnostopoulos, T [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1971-07-01

    Precipitation of carbon in {alpha} iron during a thermal treatment was followed using the magnetic after effect. A study was made of the influence of different parameters such as quenching speed, annealing rate, carbon concentration with or without impurity, irradiation effects. A transient sur-saturation occurs during dissolution of carbon in iron at 500 C. (author) [French] La precipitation du carbone dans le fer au cours d'un traitement thermique a ete suivie au moyen du trainage magnetique. L'etude de differents parametres tels que: vitesse de trempe, mode de recuit, concentration en carbone, presence d'impuretes, effet d'une irradiation, ont ete menes a bien. Un phenomene de sursaturation transitoire au cours de la remise en solution a 500 C a ete mis en evidence. (auteur)

  16. Cell for studying electron-adsorbed gas interactions; Cellule d'etudes des interactions electron-gaz adsorbe

    Energy Technology Data Exchange (ETDEWEB)

    Golowacz, H; Degras, D A [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires, Deptartement de Physique des Plasmas et de la Fusion Controlee, Service de Physique Appliquee, Service de Physique des Interractions Electroniques, Section d' Etude des Interactions Gaz-Solides

    1967-07-01

    The geometry and the technology of a cell used for investigations on electron-adsorbed gas interactions are described. The resonance frequencies of the surface ions which are created by the electron impact on the adsorbed gas are predicted by simplified calculations. The experimental data relative to carbon monoxide and neon are in good agreement with these predictions. (authors) [French] Les caracteristiques geometriques et technologiques generales d'une cellule d'etude des interactions entre un faisceau d'electrons et un gaz adsorbe sont donnees. Un calcul simplifie permet de prevoir les frequences de resonance des ions de surface crees par l'impact des electrons sur le gaz adsorbe. Les donnees experimentales sur l'oxyde de carbone et le neon confirment les previsions du calcul. (auteurs)

  17. Development of spectrometric probes for emergency preparedness. Status and way forward; Entwicklung von spektrometrierenden Sonden fuer den Notfallschutz. Stand und Perspektiven

    Energy Technology Data Exchange (ETDEWEB)

    Zaehringer, M.; Bleher, M. [Bundesamt fuer Strahlenschutz (BfS), Salzgitter (Germany); Dambacher, M. [X-Ray Imaging Europe, Freiburg (Germany); and others

    2014-01-20

    Spectrometric probes with medium energy resolution (NaI, LaBr{sub 3}, CZT) have the potential to enhance existing gamma dose rate monitoring networks as a early warning system by increasing the sensitivity and specificity. In an emergency situation nuclide specific information with sufficient spatial resolution can be made available to decision makers. An ongoing research project between BfS and the Freiburg Material Research Centre (FMF) aims at the development of semiconductor detectors based on Cadmium-Zink-Telluride which can be used for low cost ruggedized spectrometric systems suitable for deployment in an environmental network. The new probe contains also a newly developed versatile multi channel analyser. The system has a modular design and is based - where ever possible - on open source components. It is complemented by specific analysis software using established data exchange formats. This facilitates international cooperation and exploits synergies through distributed development of components.

  18. In situ probing of cholesterol in astrocytes at the single-cell level using laser desorption ionization mass spectrometric imaging with colloidal silver.

    Science.gov (United States)

    Perdian, D C; Cha, Sangwon; Oh, Jisun; Sakaguchi, Donald S; Yeung, Edward S; Lee, Young Jin

    2010-04-30

    Mass spectrometric imaging has been utilized to localize individual astrocytes and to obtain cholesterol populations at the single-cell level in laser desorption ionization (LDI) with colloidal silver. The silver ion adduct of membrane-bound cholesterol was monitored to detect individual cells. Good correlation between mass spectrometric and optical images at different cell densities indicates the ability to perform single-cell studies of cholesterol abundance. The feasibility of quantification is confirmed by the agreement between the LDI-MS ion signals and the results from a traditional enzymatic fluorometric assay. We propose that this approach could be an effective tool to study chemical populations at the cellular level. Published in 2010 by John Wiley & Sons, Ltd.

  19. The development of a very high stability electrostatic generator (1962); Etude et realisation d'un generateur electrostatique a tres haute stabilite (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Jonckheere, R E.L. [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1962-07-01

    This thesis deals with the study of an electrostatic high voltage generator having a voltage stability of the order of 10{sup -6} per minute. This equipment should be very useful in electron microscopy. The electrostatic generator is studied as a control system element: transfer function, parasitic signals and noise are determined and a mathematical model is proposed. A theoretical study of the open loop transfer function, stability, transient response, voltage stabilization of five different control systems shows which one should be able to fulfill the requirements There follows a detailed study of drift, a description of the actual system and performance data. (author) [French] Cette etude concerne un generateur electrostatique capable de fournir une tres haute tension continue dont la stabilite relative est de l'ordre de 10{sup -6} pendant une minute. Une telle performance rend cet appareillage tres utile en microscopie electronique. La generatrice electrostatique est etudiee en tant qu'element d'un systeme asservi: on determine successivement la fonction de transfert, les perturbations, le bruit de fond et le modele mathematique. L'etude de cinq differents circuits de regulation en ce qui concerne leur fonction de transfert, stabilite, reponse en regime transitoire, attenuation des perturbations, permettra de choisir le systeme qui semble le mieux repondre aux exigences. Viennent ensuite une etude detaillee de la derive, la description de la realisation pratique et les resultats de mesure. (auteur)

  20. A study of the aptitude of soils under natural conditions to retain radiostrontium; Etude de la vocation des sols en place a la retention du radiostrontium

    Energy Technology Data Exchange (ETDEWEB)

    Bovard, P; Grauby, A [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Independently of the theoretical study of the propagation of radioactivity in the soil as a result of submersions or of radioactive rain, the authors have studied directly and practically how this radioactivity can vary in the actual soil. To this end a simple, rapid method has been perfected; it makes it possible to maintain for each soil sample the natural parameters (structure, humidity, etc.) without introducing boundary effects. In the laboratory, after charging the soil samples, part of the study of the propagation of radioactivity is done by autoradiography; finally, as a practical application, the study of an atomic site illustrates the methods described. (author) [French] Independamment de l'etude theorique de la propagation de la radioactivite dans le sol a la suite de submersions ou de pluies radioactives, les auteurs ont etudie directement et pratiquement comment pourrait evoluer cette radioactivite dans les sols en place. Pour cela, une methode simple et rapide a ete mise au point; elle permet de conserver pour chaque echantillon de sol, les parametres naturels (structure, humidite, etc...), sans introduire d'effets de paroi. En laboratoire, apres mise en charge des massifs preleves, une partie de l'etude de la propagation des radioelements est realisee par autoradiographie; enfin, une application pratique, l'etude d'un site atomique, illustre l'expose. (auteur)