WorldWideScience

Sample records for speckle tracking echocardiographic

  1. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy.

    Science.gov (United States)

    Khan, Sitara G; Klettas, Dimitris; Kapetanakis, Stam; Monaghan, Mark J

    2016-03-01

    Cardiac resynchronisation therapy (CRT) can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain) has conventionally been assessed using tissue Doppler imaging (TDI), which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference ('speckles') in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT. © 2016 The authors.

  2. Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Ryohei Suzuki

    2018-02-01

    Full Text Available Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI. The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed abnormalities in myocardial deformations, including decreased early-to-late diastolic strain rate ratios in longitudinal, radial and circumferential directions, and deteriorated segmental systolic longitudinal strain. At the follow-up examinations, the cat exhibited echocardiographic left ventricular hypertrophy and was diagnosed with hypertrophic cardiomyopathy using conventional echocardiography. Relevance and novel information This is the first report on the use of two-dimensional speckle tracking echocardiography for the early detection of myocardial dysfunction in a cat with hypertrophic cardiomyopathy; the myocardial dysfunction was detected before the development of hypertrophy. The findings from this case suggest that two-dimensional speckle tracking echocardiography can be useful for myocardial assessment when conventional echocardiographic and Doppler findings are ambiguous.

  3. Feasibility, Reproducibility, and Agreement between Different Speckle Tracking Echocardiographic Techniques for the Assessment of Longitudinal Deformation

    Directory of Open Access Journals (Sweden)

    Sergio Buccheri

    2013-01-01

    Full Text Available Background. Left ventricular (LV longitudinal deformation can be assessed with new echocardiographic techniques like triplane echocardiography (3PE and four-dimensional echocardiography (4DE. We aimed to assess the feasibility, reproducibility, and agreement between these different speckle-tracking techniques for the assessment of longitudinal deformation. Methods. 101 consecutive subjects underwent echocardiographic examination. 2D cine loops from the apical views, a triplane view, and an LV 4D full volume were acquired in all subjects. LV longitudinal strain was obtained for each imaging modality. Results. 2DE analysis of LV strain was feasible in 90/101 subjects, 3PE strain in 89/101, and 4DE strain in 90/101. The mean value of 2DE and 3PE longitudinal strains was significantly higher with respect to 4DE. The relationship between 2DE and 3PE derived strains (r=0.782 was significantly higher (z=3.72, P<0.001 than that between 2DE and 4DE (r=0.429 and that between 3PE and 4DE (r=0.510; z=3.09, P=0.001. The mean bias between 2DE and 4DE strains was -6.61±7.31% while -6.42±6.81% between 3PE and 4DE strains; the bias between 2DE and 3PE strain was of 0.21±4.16%. Intraobserver and interobserver variabilities were acceptable among the techniques. Conclusions. Echocardiographic techniques for the assessment of longitudinal deformation are not interchangeable, and further studies are needed to assess specific reference values.

  4. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy

    Directory of Open Access Journals (Sweden)

    Sitara G Khan

    2016-05-01

    Full Text Available Cardiac resynchronisation therapy (CRT can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain has conventionally been assessed using tissue Doppler imaging (TDI, which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference (‘speckles’ in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT.

  5. Speckle tracking echocardiography in mature Irish Wolfhound dogs

    DEFF Research Database (Denmark)

    Westrup, Ulrik; McEvoy, Fintan

    2013-01-01

    Two-dimensional strain measurements obtained by speckle tracking echocardiography (STE) have been reported in both humans and dogs. Incorporation of this technique into canine clinical practice requires the availability of measurements from clinically normal dogs, ideally of the same breed, taken...... under normal clinical conditions.The aims of this prospective study were to assess if it is possible to obtain STE data during a routine echocardiographic examination in Irish Wolfhound dogs and that these data will provide reference values and an estimation of measurement error....

  6. Evaluation of Subclinical Left Ventricular Systolic Dysfunction in Chronic Asymptomatic Alcoholics by Speckle Tracking Echocardiography

    Directory of Open Access Journals (Sweden)

    Murathan Kucuk

    2017-01-01

    Full Text Available By using two-dimensional speckle tracking echocardiography, we aimed to investigate the structural and functional changes on myocardium in chronic asymptomatic alcoholics without any cardiovascular disease. Forty-one consecutive asymptomatic male alcoholics who were admitted to the outpatient alcoholism unit and 30 age matched healthy male volunteers selected as the control group were enrolled in the study. The study group were investigated by using standard two-dimensional echocardiography and speckle tracking echocardiography. The left ventricular (LV global longitudinal strain and LV global circumferential strain were significantly lower in alcoholics when compared with control subjects. There was no difference in global radial strain between the two groups. To demonstrate the effect of total life time dose of ethanol (TLDE on echocardiographic abnormalities, we assessed the correlation analysis. There was a nonsignificant weak correlation between global LV circumferential strain and TLDE (r=0.27, p=0.083. Speckle tracking echocardiography derived left ventricular systolic function was impaired in chronic alcoholic patients when compared with healthy controls.

  7. Type I Diabetic Akita Mouse Model is Characterized by Abnormal Cardiac Deformation During Early Stages of Diabetic Cardiomyopathy with Speckle-Tracking Based Strain Imaging.

    Science.gov (United States)

    Zhou, Yingchao; Xiao, Hong; Wu, Jianfei; Zha, Lingfeng; Zhou, Mengchen; Li, Qianqian; Wang, Mengru; Shi, Shumei; Li, Yanze; Lyu, Liangkun; Wang, Qing; Tu, Xin; Lu, Qiulun

    2018-01-01

    Diabetes mellitus (DM) has been demonstrated to have a strong association with heart failure. Conventional echocardiographic analysis cannot sensitively monitor cardiac dysfunction in type I diabetic Akita hearts, but the phenotype of heart failure is observed in molecular levels during the early stages. Male Akita (Ins2WT/C96Y) mice were monitored with echocardiographic imaging at various ages, and then with conventional echocardiographic analysis and speckle-tracking based strain analyses. With speckle-tracking based strain analyses, diabetic Akita mice showed changes in average global radial strain at the age of 12 weeks, as well as decreased longitudinal strain. These changes occurred in the early stage and remained throughout the progression of diabetic cardiomyopathy in Akita mice. Speckle-tracking showed that the detailed and precise changes of cardiac deformation in the progression of diabetic cardiomyopathy in the genetic type I diabetic Akita mice were uncoupled. We monitored early-stage changes in the heart of diabetic Akita mice. We utilize this technique to elucidate the underlying mechanism for heart failure in Akita genetic type I diabetic mice. It will further advance the assessment of cardiac abnormalities, as well as the discovery of new drug treatments using Akita genetic type I diabetic mice. © 2018 The Author(s). Published by S. Karger AG, Basel.

  8. Tracking speckle displacement by double Kalman filtering

    Institute of Scientific and Technical Information of China (English)

    Donghui Li; Li Guo

    2006-01-01

    @@ A tracking technique using two sequentially-connected Kalman filter for tracking laser speckle displacement is presented. One Kalman filter tracks temporal speckle displacement, while another Kalman filter tracks spatial speckle displacement. The temporal Kalman filter provides a prior for the spatial Kalman filter, and the spatial Kalman filter provides measurements for the temporal Kalman filter. The contribution of a prior to estimations of the spatial Kalman filter is analyzed. An optical analysis system was set up to verify the double-Kalman-filter tracker's ability of tracking laser speckle's constant displacement.

  9. X-ray pulse wavefront metrology using speckle tracking

    International Nuclear Information System (INIS)

    Berujon, Sebastien; Ziegler, Eric; Cloetens, Peter

    2015-01-01

    The theoretical description and experimental implementation of a speckle-tracking-based instrument which permits the characterisation of X-ray pulse wavefronts. An instrument allowing the quantitative analysis of X-ray pulsed wavefronts is presented and its processing method explained. The system relies on the X-ray speckle tracking principle to accurately measure the phase gradient of the X-ray beam from which beam optical aberrations can be deduced. The key component of this instrument, a semi-transparent scintillator emitting visible light while transmitting X-rays, allows simultaneous recording of two speckle images at two different propagation distances from the X-ray source. The speckle tracking procedure for a reference-less metrology mode is described with a detailed account on the advanced processing schemes used. A method to characterize and compensate for the imaging detector distortion, whose principle is also based on speckle, is included. The presented instrument is expected to find interest at synchrotrons and at the new X-ray free-electron laser sources under development worldwide where successful exploitation of beams relies on the availability of an accurate wavefront metrology

  10. MODERN POSSIBILITIES OF SPECKLE TRACKING ECHOCARDIOGRAPHY IN CLINICAL PRACTICE

    Directory of Open Access Journals (Sweden)

    V. S. Nikiforov

    2017-01-01

    Full Text Available Speckle-tracking echocardiography is promising modern technique for evaluation of structural and functional changes in the myocardium. It evaluates the indicator of global longitudinal myocardial deformation, which is more sensitive than ejection fraction to early changes of left ventricular contractility. The diagnostic capabilities of speckle tracking echocardiography are reflected in clinical recommendations and consensus statements of European Society of Cardiology (ESC, European Association of Cardiovascular Imaging (EACVI and American Society of Echocardiography (ASE. The aim of this paper is describe basic principles of speckle tracking echocardiography and clinical applications of this new technology. Attention is paid to the use of speckle tracking echocardiography in such heart pathologies as heart failure, coronary heart disease and myocardial infarction, left ventricular hypertrophy in arterial hypertension, hypertrophic cardiomyopathy and amyloidosis of the heart, valvular heart disease, constrictive pericarditis and cancer therapy-induced cardiotoxicity.

  11. Speckle Tracking and Transthyretin Amyloid Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Alexandre Marins Rocha

    Full Text Available Abstract Background: Amyloidosis is a disease caused by deposits of insoluble fibrils in extracellular spaces. The most common type of familial amyloidosis is mediated by mutation of transthyretin, especially Val30Met. Symptoms and ejection fraction decrease may occur in cardiac amyloidosis only in case of poor prognosis. Myocardial strain detected by two-dimensional speckle tracking echocardiography can indicate changes in myocardial function at early stages of the disease. Objective: To determine the accuracy of left ventricular longitudinal strain by two-dimensional speckle tracking echocardiography in patients with familial amyloidosis caused by Val30Met transthyretin mutation. Methods: Eighteen consecutive patients, carriers of transthyretin mutation, were evaluated by two-dimensional speckle tracking echocardiography, by which myocardial strain curves were obtained, following the American Society of Echocardiography recommendations. Results: Patients were divided into three groups: 1- Val30Met with cardiac amyloidosis; 2-Val30Met with extracardiac amyloidosis; 3 - Val30Met without evidence of disease. As the three groups were compared by the Mann-Whitney test, we found a statistically significant difference between groups 1 and 2 in the mean longitudinal tension (p=0.01, mean basal longitudinal strain (p=0.014; in mean longitudinal tension and mean longitudinal strain between groups 1 and 3 (p=0.005; and in the ratio of longitudinal strain of apical septum segment to longitudinal strain of basal septum (p=0.041 between groups 2 and 3. Conclusion: Left ventricular longitudinal strain detected by two-dimensional speckle tracking echocardiography is able to diagnose left ventricular dysfunction in early stages of familial amyloidosis caused by transthyretin Val30Met mutation.

  12. Changes in Speckle Tracking Echocardiography Measures of Ventricular Function after Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve in the Pulmonary Position

    Science.gov (United States)

    Chowdhury, Shahryar M.; Hijazi, Ziyad M.; Rhodes, John F.; Kar, Saibal; Makkar, Raj; Mullen, Michael; Cao, Qi-Ling; Mandinov, Lazar; Buckley, Jason; Pietris, Nicholas P.; Shirali, Girish S.

    2015-01-01

    Background Patients with free pulmonary regurgitation or mixed pulmonary stenosis and regurgitation and severely dilated right ventricles (RV) show little improvement in ventricular function after pulmonary valve replacement when assessed by traditional echocardiographic markers. We evaluated changes in right and left ventricular (LV) function using speckle tracking echocardiography in patients after SAPIEN transcatheter pulmonary valve (TPV) placement. Methods Echocardiograms were evaluated at baseline, discharge, 1 and 6 months after TPV placement in 24 patients from 4 centers. Speckle tracking measures of function included peak longitudinal strain, strain rate, and early diastolic strain rate. RV fractional area change, tricuspid annular plane systolic excursion, and left ventricular LV ejection fraction were assessed. Routine Doppler and tissue Doppler velocities were measured. Results At baseline, all patients demonstrated moderate to severe pulmonary regurgitation; this improved following TPV placement. No significant changes were detected in conventional measures of RV or LV function at 6 months. RV longitudinal strain (−16.9% vs. −19.6%, P echocardiography may be more sensitive than traditional measures in detecting changes in systolic function after TPV implantation. (Echocardiography 2015;32:461–469) PMID:25047063

  13. Usefulness of right ventricular and right atrial two-dimensional speckle tracking strain to predict late arrhythmic events in adult patients with repaired Tetralogy of Fallot.

    Science.gov (United States)

    Timóteo, Ana T; Branco, Luísa M; Rosa, Sílvia A; Ramos, Ruben; Agapito, Ana F; Sousa, Lídia; Galrinho, Ana; Oliveira, José A; Oliveira, Mário M; Ferreira, Rui C

    2017-01-01

    To determine whether right ventricular and/or atrial speckle tracking strain is associated with previous arrhythmic events in patients with repaired tetralogy of Fallot. We studied right ventricular and atrial strain in 100 consecutive patients with repaired tetralogy of Fallot referred for routine echocardiographic evaluation. Patients were divided into two groups, one with previous documentation of arrhythmias (n=26) and one without arrhythmias, in a median follow-up of 22 years. Patients with arrhythmias were older (pFallot, although a prospective study is required. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  14. Speckle-Tracking Echocardiography in Dogs With Patent Ductus Arteriosus: Effect of Percutaneous Closure on Cardiac Mechanics.

    Science.gov (United States)

    Spalla, I; Locatelli, C; Zanaboni, A M; Brambilla, P; Bussadori, C

    2016-05-01

    Patent ductus arteriosus (PDA) is 1 of the most common congenital heart defects in dogs and percutaneous closure is effective in achieving ductal closure; PDA closure is associated with abrupt hemodynamic changes. A marked decrease in standard parameters of systolic function as assessed by M- or B-mode echocardiography after PDA closure was identified in previous studies. Speckle tracking echocardiography can provide further insight into the effect of PDA closure on cardiac mechanics in dogs affected by PDA. Twenty-five client-owned dogs with PDA. Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed before and 24 hours after PDA closure, including standard (end-diastolic volumes indexed to body surface area in B- and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B- and M-mode [ESVIB /M ], allometric scaling in diastole [AlloD] and systole [AlloS], pulmonary flow to systemic flow [Qs/Qp], ejection fraction [EF], and fractional shortening [FS]), and advanced speckle-tracking echocardiography (STE): global longitudinal, radial, circumferential and transverse strain (S), and strain rate (SR). Patent ductus arteriosus closure was associated with statistically significant decreases in EDVIM /B and ESVIM /B , AlloD and AlloS, SI, EF, and FS. A statistically significant decrease in the absolute values of radial, transverse, and circumferential S and SR was observed, whereas longitudinal S and SR did not change significantly. Patent ductus arteriosus closure by percutaneous approach is associated with marked decreases of conventional echocardiographic parameters as a result of the changes in loading conditions, but no evidence of systolic dysfunction was identified by means of STE, as none of the S and SR values were below reference ranges. In the short term, contractility is enhanced in the long axis (long S/SR values were not statistically different before and after closure) and

  15. Archeological Echocardiography: Digitization and Speckle-Tracking Analysis of Archival Echocardiograms in the HyperGEN Study

    Science.gov (United States)

    Aguilar, Frank G.; Selvaraj, Senthil; Martinez, Eva E.; Katz, Daniel H.; Beussink, Lauren; Kim, Kwang-Youn A.; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R.; Arnett, Donna K.; Shah, Sanjiv J.

    2015-01-01

    Background Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle-tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. Methods In the NHLBI HyperGEN study (N=2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter/intraobserver agreement was calculated. Accuracy was evaluated in (1) a separate second study (N=50) comparing prospective digital strain vs. post-hoc analog-to-digital strain; and (2) in a third study (N=95) comparing prospectively-obtained TDI e′ velocities with post-hoc STE e′ velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Results Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intraobserver agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post-hoc STE to prospective digital STE for strain analysis. STE-derived e′ velocities correlated with, but systematically underestimated, TDI e′ velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β =−2.4 [95% CI −3.6,−1.2]% per 1-SD increase in fasting glucose; Pechocardiography, the digitization and speckle-tracking analysis of archival echocardiograms, is feasible and generates parameters of cardiac mechanics similar to contemporary studies. PMID

  16. Archeological Echocardiography: Digitization and Speckle Tracking Analysis of Archival Echocardiograms in the HyperGEN Study.

    Science.gov (United States)

    Aguilar, Frank G; Selvaraj, Senthil; Martinez, Eva E; Katz, Daniel H; Beussink, Lauren; Kim, Kwang-Youn A; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R; Arnett, Donna K; Shah, Sanjiv J

    2016-03-01

    Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. In the NHLBI HyperGEN study (N = 2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter-/intra-observer agreement was calculated. Accuracy was evaluated in: (1) a separate second study (N = 50) comparing prospective digital strain versus post hoc analog-to-digital strain, and (2) in a third study (N = 95) comparing prospectively obtained TDI e' velocities with post hoc STE e' velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intra-observer agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post hoc STE to prospective digital STE for strain analysis. STE-derived e' velocities correlated with, but systematically underestimated, TDI e' velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β = -2.4 [95% CI -3.6, -1.2]% per 1-SD increase in fasting glucose; P echocardiography, the digitization and speckle tracking analysis of archival echocardiograms, is feasible and generates indices of cardiac mechanics similar to contemporary studies. © 2015, Wiley Periodicals, Inc.

  17. Left ventricular strain and strain rate by 2D speckle tracking in chronic thromboembolic pulmonary hypertension before and after pulmonary thromboendarterectomy

    Directory of Open Access Journals (Sweden)

    Waltman Thomas J

    2010-09-01

    Full Text Available Abstract Background Echocardiographic evaluation of left ventricular (LV strain and strain rate (SR by 2D speckle tracking may be useful tools to assess chronic thromboembolic pulmonary hypertension (CTEPH severity as well as response to successful pulmonary thromboendarterectomy (PTE. Methods We evaluated 30 patients with CTEPH before and after PTE using 2D speckle tracking measurements of LV radial and circumferential strain and SR in the short axis, and correlated the data with right heart catheterization (RHC. Results PTE resulted in a decrease in mean PA pressure (44 ± 15 to 29 ± 9 mmHg, decrease in PVR (950 ± 550 to 31 ± 160 [dyne-sec]/cm5, and an increase in cardiac output (3.9 ± 1.0 to 5.0 ± 1.0 L/min, p change in circumferential strain and change in posterior wall radial strain correlated moderately well with changes in PVR, mean PA pressure and cardiac output (r = 0.69, 0.76, and 0.51 for circumferential strain [p Conclusions LV circumferential and posterior wall radial strain change after relief of pulmonary arterial obstruction in patients with CTEPH, and these improvements occur rapidly. These changes in LV strain may reflect effects from improved LV diastolic filling, and may be useful non-invasive markers of successful PTE.

  18. Optimal Analysis of Left Atrial Strain by Speckle Tracking Echocardiography: P-wave versus R-wave Trigger.

    Science.gov (United States)

    Hayashi, Shuji; Yamada, Hirotsugu; Bando, Mika; Saijo, Yoshihito; Nishio, Susumu; Hirata, Yukina; Klein, Allan L; Sata, Masataka

    2015-08-01

    Left atrial (LA) strain analysis using speckle tracking echocardiography is useful for assessing LA function. However, there is no established procedure for this method. Most investigators have determined the electrocardiographic R-wave peak as the starting point for LA strain analysis. To test our hypothesis that P-wave onset should be used as the starting point, we measured LA strain using 2 different starting points and compared the strain values with the corresponding LA volume indices obtained by three-dimensional (3D) echocardiography. We enrolled 78 subjects (61 ± 17 years, 25 males) with and without various cardiac diseases in this study and assessed global longitudinal LA strain by two-dimensional speckle tracking strain echocardiography using EchoPac software. We used either R-wave peak or P-wave onset as the starting point for determining LA strains during the reservoir (Rres, Pres), conduit (Rcon, Pcon), and booster pump (Rpump, Ppump) phases. We determined the maximum, minimum, and preatrial contraction LA volumes, and calculated the LA total, passive, and active emptying fractions using 3D echocardiography. The correlation between Pres and LA total emptying fraction was better than the correlation between Rres and LA total emptying fraction (r = 0.458 vs. 0.308, P = 0.026). Pcon and Ppump exhibited better correlation with the corresponding 3D echocardiographic parameters than Rcon (r = 0.560 vs. 0.479, P = 0.133) and Rpump (r = 0.577 vs. 0.345, P = 0.003), respectively. LA strain in any phase should be analyzed using P-wave onset as the starting point rather than R-wave peak. © 2014, Wiley Periodicals, Inc.

  19. [Speckle tracking--a new ultrasound tool for the assessment of fetal myocardial function].

    Science.gov (United States)

    Willruth, A; Geipel, A; Merz, W; Gembruch, U

    2012-06-01

    Speckle tracking is a new ultrasound tool to assess 2D ventricular global and segmental myocardial velocity and deformation (strain, strain rate). Multiple factors such as fetal motion, high heart rates, low blood pressure, small size of the heart, physiological cardiac translation, filling and maturational changes of myocardium, polyhydramnion, maternal obesity and aortic pulsation can degrade the image quality and result in artifacts and measurement errors which may have an impact on the final analysis. Therefore deformation indices such as strain and strain rate offer a quantitative technique for the estimation of global and segmental myocardial function and contractility. At present longitudinal peak systolic strain is the most commonly applied deformation parameter used to analyse segmental and global myocardial contractility in adults. When obtained using Doppler methods, these measurements are angle dependent, whereas speckle tracking techniques overcome the limitations of Doppler echocardiography which is a particular advantage in foetal echocardiography. Nevertheless, the time and training necessary to acquire high-quality video clips limit the implementation of speckle tracking into clinical routine. It is not yet clear whether this new technique will identify subclinical myocardial impairment earlier than with current techniques or allow for better discrimination between healthy fetuses and fetuses with congenital heart disease. The clinical use of speckle tracking will have to be demonstrated in larger groups of complicated pregnancies. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Real-time three-dimensional speckle tracking echocardiography: technical aspects and clinical applications

    Directory of Open Access Journals (Sweden)

    Sorrentino R

    2016-11-01

    Full Text Available Regina Sorrentino, Roberta Esposito, Enrica Pezzullo, Maurizio Galderisi Department of Advanced Biomedical Sciences, Interdepartmental Laboratory of Cardiac Imaging, Federico II University Hospital, Naples, Italy Abstract: Three-dimensional speckle tracking echocardiography (3D STE is a novel technique for the quantification of cardiac deformation based on tracking of ultrasonic speckles in gray scale full-volume 3D images. Developments in ultrasound technologies have made 3D speckle tracking widely available. Two-dimensional echocardiography has intrinsic limitations regarding estimation of left ventricular (LV volumes, ejection fraction, and LV mechanics, due to its inherent foreshortening errors and dependency on geometric models. The development of 3D echocardiography has improved reproducibility and accuracy. Data regarding the feasibility, accuracy, and clinical applications of 3D STE are rapidly assembling. From the tracking results, 3D STE derives several parameters, including longitudinal, circumferential and radial strain, as well as a combined assessment of longitudinal and circumferential strain, termed area strain. 3D STE can also quantify LV rotational movements such as rotation, twist, and torsion. 3D STE provides a better insight on global and regional myocardial deformation. Main applications include detection of subclinical myocardial involvement in heart failure, arterial hypertension, dyssynchrony, and ischemic heart disease. Emerging areas of application include a large spectrum of heart-involving systemic conditions, such as prediction of rejection in heart transplant patients, early detection of cardiotoxicity in patients receiving chemotherapy for cancer, and deeper physiological understanding of LV contraction mechanics in different types of athletes. Aim of this review is to discuss background, technical acquisition and processing aspects as well as recognized and developing clinical applications of this emerging

  1. Impact of transducer frequency setting on speckle tracking measures

    DEFF Research Database (Denmark)

    Olsen, Flemming Javier; Svendsen, Jesper Hastrup; Køber, Lars

    2018-01-01

    .5/3.0 MHz. The images were obtained immediately after each other at the exact same position for the two settings. Speckle tracking was performed in three apical projections, allowing for acquisition of layered global longitudinal strain (GLS) and strain rate measures. Concordance between the frequency...

  2. Speckle-tracking echocardiography for predicting outcome in chronic aortic regurgitation during conservative management and after surgery

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; Søgaard, Peter; Larsson, Henrik B W

    2011-01-01

    Objectives The aim of this study was to test myocardial deformation imaging using speckle-tracking echocardiography for predicting outcomes in chronic aortic regurgitation. Background In chronic aortic regurgitation, left ventricular (LV) dysfunction must be detected early to allow timely surgery....... Speckle-tracking echocardiography has been proposed for this purpose, but the clinical value of this method in aortic regurgitation has not been established. Methods A longitudinal study was performed in 64 patients with moderate to severe aortic regurgitation. Thirty-five patients were managed...... conservatively with frequent clinical visits and sequential echocardiography and followed for an average of 19 ± 8 months, while 29 patients underwent surgery for the valve lesion and were followed for 6 months post-operatively. Baseline LV function by speckle-tracking and conventional echocardiography...

  3. Speckle tracking echocardiography in acute lupus myocarditis: comparison to conventional echocardiography

    Directory of Open Access Journals (Sweden)

    Riëtte Du Toit

    2017-07-01

    Full Text Available Aims: Lupus myocarditis occurs in 5–10% of patients with systemic lupus erythematosus (SLE. No single feature is diagnostic of lupus myocarditis. Speckle tracking echocardiography (STE can detect subclinical left ventricular dysfunction in SLE patients, with limited research on its utility in clinical lupus myocarditis. We report on STE in comparison to conventional echocardiography in patients with clinical lupus myocarditis. Methods and results: A retrospective study was done at a tertiary referral hospital in South Africa. SLE patients with lupus myocarditis were included and compared to healthy controls. Echocardiographic images were reanalyzed, including global longitudinal strain through STE. A poor echocardiographic outcome was defined as final left ventricular ejection fraction (LVEF <40%. 28 SLE patients fulfilled the criteria. Global longitudinal strain correlated with global (LVEF: r = −0.808; P = 0.001 and regional (wall motion score: r = 0.715; P < 0.001 function. In patients presenting with a LVEF ≥50%, global longitudinal strain (P = 0.023, wall motion score (P = 0.005 and diastolic function (P = 0.004 were significantly impaired vs controls. Following treatment, LVEF (35–47% (P = 0.023 and wall motion score (1.88–1.5 (P = 0.017 improved but not global longitudinal strain. Initial LVEF (34%; P = 0.046 and global longitudinal strain (−9.5%; P = 0.095 were lower in patients with a final LVEF <40%. Conclusions: This is the first known report on STE in a series of patients with clinical lupus myocarditis. Global longitudinal strain correlated with regional and global left ventricular function. Global longitudinal strain, wall motion score and diastolic parameters may be more sensitive markers of lupus myocarditis in patients presenting with a preserved LVEF ≥50%. A poor initial LVEF and global longitudinal strain were associated with a persistent LVEF <40%. Echocardiography is a non-invasive tool with diagnostic and

  4. Speckle tracking echocardiography in chronic obstructive pulmonary disease and overlapping obstructive sleep apnea.

    Science.gov (United States)

    Pizarro, Carmen; van Essen, Fabian; Linnhoff, Fabian; Schueler, Robert; Hammerstingl, Christoph; Nickenig, Georg; Skowasch, Dirk; Weber, Marcel

    2016-01-01

    COPD and congestive heart failure represent two disease entities of growing global burden that share common etiological features. Therefore, we aimed to identify the degree of left ventricular (LV) dysfunction in COPD as a function of COPD severity stages and concurrently placed particular emphasis on the presence of overlapping obstructive sleep apnea (OSA). A total of 85 COPD outpatients (64.1±10.4 years, 54.1% males) and 20 controls, matched for age, sex, and smoking habits, underwent speckle tracking echocardiography for LV longitudinal strain imaging. Complementary 12-lead electrocardiography, laboratory testing, and overnight screening for sleep-disordered breathing using the SOMNOcheck micro(®) device were performed. Contrary to conventional echocardiographic parameters, speckle tracking echocardiography revealed significant impairment in global LV strain among COPD patients compared to control smokers (-13.3%±5.4% vs -17.1%±1.8%, P=0.04). On a regional level, the apical septal LV strain was reduced in COPD (P=0.003) and associated with the degree of COPD severity (P=0.02). With regard to electrocardiographic findings, COPD patients exhibited a significantly higher mean heart rate than controls (71.4±13.0 beats per minute vs 60.3±7.7 beats per minute, P=0.001) that additionally increased over Global Initiative for Chronic Obstructive Lung Disease stages (P=0.01). Albeit not statistically significant, COPD led to elevated N-terminal pro-brain natriuretic peptide levels (453.2±909.0 pg/mL vs 96.8±70.0 pg/mL, P=0.08). As to somnological testing, the portion of COPD patients exhibiting overlapping OSA accounted for 5.9% and did not significantly vary either in comparison to controls (P=0.07) or throughout the COPD Global Initiative for Chronic Obstructive Lung Disease stages (P=0.49). COPD-OSA overlap solely correlated with nocturnal hypoxemic events, whereas LV performance status was unrelated to coexisting OSA. To conclude, COPD itself seems to be

  5. Strain dyssynchrony index determined by three-dimensional speckle area tracking can predict response to cardiac resynchronization therapy

    Directory of Open Access Journals (Sweden)

    Onishi Tetsuari

    2011-04-01

    Full Text Available Abstract Background We have previously reported strain dyssynchrony index assessed by two-dimensional speckle tracking strain, and a marker of both dyssynchrony and residual myocardial contractility, can predict response to cardiac resynchronization therapy (CRT. A newly developed three-dimensional (3-D speckle tracking system can quantify endocardial area change ratio (area strain, which coupled with the factors of both longitudinal and circumferential strain, from all 16 standard left ventricular (LV segments using complete 3-D pyramidal datasets. Our objective was to test the hypothesis that strain dyssynchrony index using area tracking (ASDI can quantify dyssynchrony and predict response to CRT. Methods We studied 14 heart failure patients with ejection fraction of 27 ± 7% (all≤35% and QRS duration of 172 ± 30 ms (all≥120 ms who underwent CRT. Echocardiography was performed before and 6-month after CRT. ASDI was calculated as the average difference between peak and end-systolic area strain of LV endocardium obtained from 3-D speckle tracking imaging using 16 segments. Conventional dyssynchrony measures were assessed by interventricular mechanical delay, Yu Index, and two-dimensional radial dyssynchrony by speckle-tracking strain. Response was defined as a ≥15% decrease in LV end-systolic volume 6-month after CRT. Results ASDI ≥ 3.8% was the best predictor of response to CRT with a sensitivity of 78%, specificity of 100% and area under the curve (AUC of 0.93 (p Conclusions ASDI can predict responders and LV reverse remodeling following CRT. This novel index using the 3-D speckle tracking system, which shows circumferential and longitudinal LV dyssynchrony and residual endocardial contractility, may thus have clinical significance for CRT patients.

  6. Variability of global left ventricular deformation analysis using vendor dependent and independent two-dimensional speckle-tracking software in adults

    DEFF Research Database (Denmark)

    Risum, Niels; Ali, Sophia; Olsen, Niels T

    2012-01-01

    Evaluation of myocardial deformation by two-dimensional speckle-tracking is useful for clinical and research purposes. However, differences may exist among different ultrasound machines, software packages, frame rates, and observers.......Evaluation of myocardial deformation by two-dimensional speckle-tracking is useful for clinical and research purposes. However, differences may exist among different ultrasound machines, software packages, frame rates, and observers....

  7. Acute myocarditis with normal wall motion detected with 2D speckle tracking echocardiography

    Directory of Open Access Journals (Sweden)

    Thomas Sturmberger

    2016-05-01

    Full Text Available We present the case of a 26-year-old male with acute tonsillitis who was referred for coronary angiography because of chest pain, elevated cardiac biomarkers, and biphasic T waves. The patient had no cardiovascular risk factors. Echocardiography showed no wall motion abnormalities and no pericardial effusion. 2D speckle tracking revealed distinct decreased regional peak longitudinal systolic strain in the lateral and posterior walls. Ischemic disease was extremely unlikely in view of his young age, negative family history regarding coronary artery disease, and lack of regional wall motion abnormalities on the conventional 2D echocardiogram. Coronary angiography was deferred as myocarditis was suspected. To confirm the diagnosis, cardiac magnetic resonance tomography (MRT was performed, showing subepicardial delayed hyperenhancement in the lateral and posterior walls correlating closely with the strain pattern obtained by 2D speckle tracking echocardiography. With a working diagnosis of acute myocarditis associated with acute tonsillitis, we prescribed antibiotics and nonsteroidal anti-inflammatory drugs. The patient’s clinical signs resolved along with normalization of serum creatine kinase (CK levels, and the patient was discharged on the third day after admission. Learning points: • Acute myocarditis can mimic acute coronary syndromes. • Conventional 2D echocardiography lacks specific features for detection of subtle regional wall motion abnormalities. • 2D speckle tracking expands the scope of echocardiography in identifying myocardial dysfunction derived from edema in acute myocarditis.

  8. Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.

    Science.gov (United States)

    Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T

    2013-04-01

    Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Usefulness of left ventricular speckle tracking echocardiography and novel measures of left atrial structure and function in diagnosing paroxysmal atrial fibrillation in ischemic stroke and transient ischemic attack patients.

    Science.gov (United States)

    Skaarup, Kristoffer Grundtvig; Christensen, Hanne; Høst, Nis; Mahmoud, Masti Mahdy; Ovesen, Christian; Olsen, Flemming Javier; Jensen, Jan Skov; Biering-Sørensen, Tor

    2017-12-01

    Asymptomatic paroxysmal atrial fibrillation (PAF) is often assumed to be the cause of cryptogenic ischemic strokes (IS) and transient ischemic attacks (TIA). We examined the usefulness of measures obtained by 2D speckle tracking echocardiography and novel left atrial measurements, in the diagnosis of PAF in patients with IS and TIA. We retrospectively included 205 patients who after acute IS or TIA underwent an echocardiogram in sinus rhythm. Patients were designated as PAF-patients if they had one or more reported incidents of AF before or after their echocardiographic examination. None of the conventional echocardiographic parameters were significantly associated with PAF. Of the speckle tracking measurements, only early diastolic strain rate (0.7±0.2 s -1 vs. 0.8±0.3 s -1 , p = 0.048) and global longitudinal displacement (GLD) (3.15 ± 1.40 mm vs. 3.87 ± 1.56 mm, p = 0.007) proved significantly different. Of the left atrial parameters both minimal and maximal left atrium volume divided by left ventricular length (min LAV/LVL and max LAV/LVL, respectively) were significantly impaired (min LAV/LVL: 3.7 ± 2.1 cm 2 vs. 2.8 ± 1.11 cm 2 , p = 0.012; max LAV/LVL: 6.6 ± 3.1 cm 2 vs. 5.6 ± 1.7 cm 2 , p = 0.012). GLD, min max LAV/LVL proved significant after adjustment for age, gender, CHA 2 DS 2 -VASc and NIHSS. By combining information regarding age, GLD, min and max LAV/LVL the diagnostic accuracy of PAF improved, resulting in a significantly increased area under the curve (p = 0.037). In patients with IS and TIA GLD, min and max LAV/LVL were independently associated with the presence of PAF.

  10. Mechanical dispersion and global longitudinal strain by speckle tracking echocardiography: Predictors of appropriate implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy.

    Science.gov (United States)

    Candan, Ozkan; Gecmen, Cetin; Bayam, Emrah; Guner, Ahmet; Celik, Mehmet; Doğan, Cem

    2017-06-01

    In this study, we investigated whether mechanical dispersion which reflects electrical abnormality and other echocardiographic and clinic parameters predict appropriate ICD shock in patients undergone ICD implantation for hypertrophic cardiomyopathy. Sixty-three patients who received ICD implantation for primary or secondary prevention were included in the study. Patients' clinical, electrocardiographic, 2D classic, and speckle tracking echocardiographic data were collected. Mechanical dispersion was defined as the standard deviation of time to peak negative strain in 18 left ventricular segments. Appropriate ICD therapy was defined as cardioversion or defibrillation due to ventricular tachycardia or fibrillation. Patients were divided into two groups as occurrence or the absence of appropriate ICD therapy. A total of 17 (26.9%) patients were observed to have an appropriate ICD therapy during follow-up periods. In patients who performed appropriate ICD therapy, a larger left atrial volume index, higher sudden cardiac death (SCD)-Risk Score, longer mechanical dispersion, and decreased global longitudinal peak strain (GLPS) were observed. In multivariate logistic regression analysis, including (GLPS, mechanical dispersion, LAVi, and SCD-Risk Score) was used to determine independent predictors of occurrence of appropriate ICD therapy during the follow-up. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be independent predictors of occurrence of appropriate ICD therapy. Mechanical dispersion, GLPS, and SCD-Risk Score were found to be predictive for appropriate ICD therapy in patients receiving ICD implantation. Readily measurable mechanical dispersion and GLPS could be helpful to distinguish patients at high risk who could optimally benefit from ICD therapy. © 2017, Wiley Periodicals, Inc.

  11. Estudo da Mecânica Cardíaca pelo Speckle Tracking

    Directory of Open Access Journals (Sweden)

    Maria Cristina Donadio Abduch

    2014-04-01

    Full Text Available Speckles, ou marcadores naturais do miocárdio, originam se da interferência construtiva e destrutiva do feixe de ultrassom que incide sobre os tecidos, podem fornecer um diagnóstico precoce das alterações miocárdicas e atuar na predição de certos eventos cardíacos. Devido à sua relativa estabilidade temporal, os speckles podem ser rastreados durante o ciclo cardíaco por software dedicados, promovendo a análise da função sistólica e diastólica. São identificados tanto pela escala de cinza da ecocardiografia 2D convencional quanto pela ecocardiografia 3D, sendo independentes do ângulo de incidência do ultrassom, permitindo assim a avaliação da mecânica cardíaca nos três planos espaciais: longitudinal, circunferencial e radial. O objetivo do presente artigo é discutir o papel e o significado da deformação cardíaca obtida por meio do speckle tracking durante a avaliação da fisiologia cardíaca, e discutir as aplicações clínicas desta tecnologia ecocardiográfica inovadora.

  12. Quantification of global myocardial function by cine MRI deformable registration-based analysis: Comparison with MR feature tracking and speckle-tracking echocardiography.

    Science.gov (United States)

    Lamacie, Mariana M; Thavendiranathan, Paaladinesh; Hanneman, Kate; Greiser, Andreas; Jolly, Marie-Pierre; Ward, Richard; Wintersperger, Bernd J

    2017-04-01

    To evaluate deformable registration algorithms (DRA)-based quantification of cine steady-state free-precession (SSFP) for myocardial strain assessment in comparison with feature-tracking (FT) and speckle-tracking echocardiography (STE). Data sets of 28 patients/10 volunteers, undergoing same-day 1.5T cardiac MRI and echocardiography were included. LV global longitudinal (GLS), circumferential (GCS) and radial (GRS) peak systolic strain were assessed on cine SSFP data using commercially available FT algorithms and prototype DRA-based algorithms. STE was applied as standard of reference for accuracy, precision and intra-/interobserver reproducibility testing. DRA showed narrower limits of agreement compared to STE for GLS (-4.0 [-0.9,-7.9]) and GCS (-5.1 [1.1,-11.2]) than FT (3.2 [11.2,-4.9]; 3.8 [13.9,-6.3], respectively). While both DRA and FT demonstrated significant differences to STE for GLS and GCS (all pcine MRI. • Inverse DRA demonstrated superior reproducibility compared to feature-tracking (FT) methods. • Cine MR DRA and FT analysis demonstrate differences to speckle-tracking echocardiography • DRA demonstrated better correlation with STE than FT for MR-derived global strain data.

  13. Speckle-tracking strain assessment of left ventricular dysfunction in synthetic cannabinoid and heroin users.

    Science.gov (United States)

    Demirkıran, Aykut; Albayrak, Neslihan; Albayrak, Yakup; Zorkun, Cafer Sadık

    2018-06-01

    There is growing evidence regarding the numerous adverse effects of synthetic cannabinoids (SCBs) on the cardiovascular system; however, no studies have shown the cardiovascular effects of opioids using strain echocardiography. This study examines the cardiac structure and function using echocardiographic strain imaging in heroin and synthetic cannabinoid users. This double-blind study included patients who were admitted or referred to a rehabilitation center for heroin (n=31) and synthetic cannabinoid users (n=30). Heroin users and synthetic cannabinoid users were compared with healthy volunteers (n=32) using two-dimensional (2D) speckle-tracking (ST) echocardiography. No differences were found in the baseline characteristics and 2D echocardiography values. The mean global longitudinal strain value was -20.5%±2.4% for SCB users, -22.3%±2.4% for opioid users, and -22.5%±2.2% for healthy volunteers (p=0.024). The mean apical 2-chamber (AP2C) L-strain values were -20.1%±3.1%, -22.4%±3.0%, and -22.3%±2.8% for SCB users, opioid users, and healthy volunteers, respectively (p=0.032). The mean apical 4-chamber (AP4C) L-strain values were -20.7%±2.5% for SCB users, -23.2%±3.2% for opioid users, and -23.8%±3.1% for healthy volunteers (p<0.001). SCBs are potential causes of subclinical left ventricular dysfunction.

  14. The septal bulge--an early echocardiographic sign in hypertensive heart disease.

    Science.gov (United States)

    Gaudron, Philipp Daniel; Liu, Dan; Scholz, Friederike; Hu, Kai; Florescu, Christiane; Herrmann, Sebastian; Bijnens, Bart; Ertl, Georg; Störk, Stefan; Weidemann, Frank

    2016-01-01

    Patients in the early stage of hypertensive heart disease tend to have normal echocardiographic findings. The aim of this study was to investigate whether pathology-specific echocardiographic morphologic and functional parameters can help to detect subclinical hypertensive heart disease. One hundred ten consecutive patients without a history and medication for arterial hypertension (AH) or other cardiac diseases were enrolled. Standard echocardiography and two-dimensional speckle-tracking-imaging analysis were performed. Resting blood pressure (BP) measurement, cycle ergometer test (CET), and 24-hour ambulatory BP monitoring (ABPM) were conducted. Patients were referred to "septal bulge (SB)" group (basal-septal wall thickness ≥ 2 mm thicker than mid-septal wall thickness) or "no-SB" group. Echocardiographic SB was found in 48 (43.6%) of 110 patients. In this SB group, 38 (79.2%) patients showed AH either by CET or ABPM. In contrast, in the no-SB group (n = 62), 59 (95.2%) patients had no positive test for AH by CET or ABPM. When AH was solely defined by resting BP, SB was a reasonable predictive sign for AH (sensitivity 73%, specificity 76%). However, when AH was confirmed by CET or ABPM the echocardiographic SB strongly predicted clinical AH (sensitivity 93%, specificity 86%). In addition, regional myocardial deformation of the basal-septum in SB group was significantly lower than in no-SB group (14 ± 4% vs. 17 ± 4%; P heart disease. Sophisticated BP evaluation including resting BP, ABPM, and CET should be performed in all patients with an accidental finding of a SB in echocardiography. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  15. 2D-speckle tracking right ventricular strain to assess right ventricular systolic function in systolic heart failure. Analysis of the right ventricular free and posterolateral walls.

    Science.gov (United States)

    Mouton, Stéphanie; Ridon, Héléne; Fertin, Marie; Pentiah, Anju Duva; Goémine, Céline; Petyt, Grégory; Lamblin, Nicolas; Coisne, Augustin; Foucher-Hossein, Claude; Montaigne, David; de Groote, Pascal

    2017-10-15

    Right ventricular (RV) systolic function is a powerful prognostic factor in patients with systolic heart failure. The accurate estimation of RV function remains difficult. The aim of the study was to determine the diagnostic accuracy of 2D-speckle tracking RV strain in patients with systolic heart failure, analyzing both free and posterolateral walls. Seventy-six patients with dilated cardiopathy (left ventricular end-diastolic volume≥75ml/m 2 ) and left ventricular ejection fraction≤45% had an analysis of the RV strain. Feasibility, reproducibility and diagnostic accuracy of RV strain were analyzed and compared to other echocardiographic parameters of RV function. RV dysfunction was defined as a RV ejection fraction≤40% measured by radionuclide angiography. RV strain feasibility was 93.9% for the free-wall and 79.8% for the posterolateral wall. RV strain reproducibility was good (intra-observer and inter-observer bias and limits of agreement of 0.16±1.2% [-2.2-2.5] and 0.84±2.4 [-5.5-3.8], respectively). Patients with left heart failure have a RV systolic dysfunction that can be unmasked by advanced echocardiographic imaging: mean RV strain was -21±5.7% in patients without RV dysfunction and -15.8±5.1% in patients with RV dysfunction (p=0.0001). Mean RV strain showed the highest diagnostic accuracy to predict depressed RVEF (area under the curve (AUC) 0.75) with moderate sensitivity (60.5%) but high specificity (87.5%) using a cutoff value of -16%. RV strain seems to be a promising and more efficient measure than previous RV echocardiographic parameters for the diagnosis of RV systolic dysfunction. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. SU-D-210-05: The Accuracy of Raw and B-Mode Image Data for Ultrasound Speckle Tracking in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    O’Shea, T; Bamber, J; Harris, E [The Institute of Cancer Research & Royal Marsden, Sutton and London (United Kingdom)

    2015-06-15

    Purpose: For ultrasound speckle tracking there is some evidence that the envelope-detected signal (the main step in B-mode image formation) may be more accurate than raw ultrasound data for tracking larger inter-frame tissue motion. This study investigates the accuracy of raw radio-frequency (RF) versus non-logarithmic compressed envelope-detected (B-mode) data for ultrasound speckle tracking in the context of image-guided radiation therapy. Methods: Transperineal ultrasound RF data was acquired (with a 7.5 MHz linear transducer operating at a 12 Hz frame rate) from a speckle phantom moving with realistic intra-fraction prostate motion derived from a commercial tracking system. A normalised cross-correlation template matching algorithm was used to track speckle motion at the focus using (i) the RF signal and (ii) the B-mode signal. A range of imaging rates (0.5 to 12 Hz) were simulated by decimating the imaging sequences, therefore simulating larger to smaller inter-frame displacements. Motion estimation accuracy was quantified by comparison with known phantom motion. Results: The differences between RF and B-mode motion estimation accuracy (2D mean and 95% errors relative to ground truth displacements) were less than 0.01 mm for stable and persistent motion types and 0.2 mm for transient motion for imaging rates of 0.5 to 12 Hz. The mean correlation for all motion types and imaging rates was 0.851 and 0.845 for RF and B-mode data, respectively. Data type is expected to have most impact on axial (Superior-Inferior) motion estimation. Axial differences were <0.004 mm for stable and persistent motion and <0.3 mm for transient motion (axial mean errors were lowest for B-mode in all cases). Conclusions: Using the RF or B-mode signal for speckle motion estimation is comparable for translational prostate motion. B-mode image formation may involve other signal-processing steps which also influence motion estimation accuracy. A similar study for respiratory-induced motion

  17. Left Atrial Deformation Analysis in Patients with Corrected Tetralogy of Fallot by 3D Speckle-Tracking Echocardiography (from the MAGYAR-Path Study)

    Science.gov (United States)

    Havasi, Kálmán; Domsik, Péter; Kalapos, Anita; McGhie, Jackie S.; Roos-Hesselink, Jolien W.; Forster, Tamás; Nemes, Attila

    2017-01-01

    Background Three-dimensional (3D) echocardiography coupled with speckle-tracking echocardiographic (STE) capability is a novel methodology which has been demontrated to be useful for the assessment of left atrial (LA) volumes and functional properties. There is increased scientific interest on myocardial deformation analysis in adult patients with corrected tetralogy of Fallot (cTOF). Objectives To compare LA volumes, volume-based functional properties and strain parameters between cTOF patients and age- and gender-matched healthy controls. Methods The study population consisted of 19 consecutive adult patients with cTOF in sinus rhythm nursing at the University of Szeged, Hungary (mean age: 37.9 ± 11.3 years, 8 men, who had repair at the age of 4.1 ± 2.5 years). They all had undergone standard transthoracic two-dimensional Doppler echocardiographic study extended with 3DSTE. Their results were compared to 23 age- and gender-matched healthy controls (mean age: 39.2 ± 10.6 years, 14 men). Results Increased LA volumes and reduced LA emptying fractions respecting cardiac cycle could be demonstrated in cTOF patients compared to controls. LA stroke volumes featuring all LA functions showed no differences between the 2 groups examined. LA global and mean segmental uni- and multidirectional peak strains featuring LA reservoir function were found to be diminished in adult patients with cTOF as compared to controls. Similarly to peak strains reduced global and mean segmental LA strains at atrial contraction characterizing atrial booster pump function could be demonstrated in cTOF patients as compared to controls. Conclusions Significant deterioration of all LA functions could be demonstrated in adult patients with cTOF late after repair. PMID:28327874

  18. Left Atrial Deformation Analysis in Patients with Corrected Tetralogy of Fallot by 3D Speckle-Tracking Echocardiography (from the MAGYAR-Path Study

    Directory of Open Access Journals (Sweden)

    Kálmán Havasi

    Full Text Available Abstract Background: Three-dimensional (3D echocardiography coupled with speckle-tracking echocardiographic (STE capability is a novel methodology which has been demontrated to be useful for the assessment of left atrial (LA volumes and functional properties. There is increased scientific interest on myocardial deformation analysis in adult patients with corrected tetralogy of Fallot (cTOF. Objectives: To compare LA volumes, volume-based functional properties and strain parameters between cTOF patients and age- and gender-matched healthy controls. Methods: The study population consisted of 19 consecutive adult patients with cTOF in sinus rhythm nursing at the University of Szeged, Hungary (mean age: 37.9 ± 11.3 years, 8 men, who had repair at the age of 4.1 ± 2.5 years. They all had undergone standard transthoracic two-dimensional Doppler echocardiographic study extended with 3DSTE. Their results were compared to 23 age- and gender-matched healthy controls (mean age: 39.2 ± 10.6 years, 14 men. Results: Increased LA volumes and reduced LA emptying fractions respecting cardiac cycle could be demonstrated in cTOF patients compared to controls. LA stroke volumes featuring all LA functions showed no differences between the 2 groups examined. LA global and mean segmental uni- and multidirectional peak strains featuring LA reservoir function were found to be diminished in adult patients with cTOF as compared to controls. Similarly to peak strains reduced global and mean segmental LA strains at atrial contraction characterizing atrial booster pump function could be demonstrated in cTOF patients as compared to controls. Conclusions: Significant deterioration of all LA functions could be demonstrated in adult patients with cTOF late after repair.

  19. Wall-motion tracking in fetal echocardiography-Influence of frame rate on longitudinal strain analysis assessed by two-dimensional speckle tracking.

    Science.gov (United States)

    Enzensberger, Christian; Achterberg, Friederike; Graupner, Oliver; Wolter, Aline; Herrmann, Johannes; Axt-Fliedner, Roland

    2017-06-01

    Frame rates (FR) used for strain analysis assessed by speckle tracking in fetal echocardiography show a considerable variation. The aim of this study was to investigate the influence of the FR on strain analysis in 2D speckle tracking. Fetal echocardiography was performed prospectively on a Toshiba Aplio 500 system and a Toshiba Artida system, respectively. Based on an apical or basal four-chamber view of the fetal heart, cine loops were stored with a FR of 30 fps (Aplio 500) and 60 fps (Artida/Aplio 500). For both groups (30fps and 60fps), global and segmental longitudinal peak systolic strain (LPSS) values of both, left (LV) and right ventricle (RV), were assessed by 2D wall-motion tracking. A total of 101 fetuses, distributed to three study groups, were included. The mean gestational age was 25.2±5.0 weeks. Mean global LPSS values for RV in the 30 fps group and in the 60 fps group were -16.07% and -16.47%, respectively. Mean global LPSS values for LV in the 30 fps group and in the 60 fps group were -17.54% and -17.06%, respectively. Comparing global and segmental LPSS values of both, the RV and LV, did not show any statistically significant differences within the two groups. Performance of myocardial 2D strain analysis by wall-motion tracking was feasible with 30 and 60 fps. Obtained global and segmental LPSS values of both ventricles were relatively independent from acquisition rate. © 2017, Wiley Periodicals, Inc.

  20. Adult echocardiographic nomograms: overview, critical review and creation of a software for automatic, fast and easy calculation of normal values.

    Science.gov (United States)

    Cantinotti, Massimiliano; Giordano, Raffaele; Paterni, Marco; Saura, Daniel; Scalese, Marco; Franchi, Eliana; Assanta, Nadia; Koestenberg, Martin; Dulgheru, Raluca; Sugimoto, Tadafumi; Bernard, Anne; Caballero, Luis; Lancellotti, Patrizio

    2017-12-01

    There is a crescent interest on normal adult echocardiographic values and the introduction of new deformation imaging and 3D parameters pose the issue of normative data. A multitude of nomograms has been recently published, however data are often fragmentary, difficult to find, and their strengths/limitations have been never evaluated. (I) to provide a review of current echocardiographic nomograms; (II) to generate a tool for easy and fast access to these data. A literature search was conducted accessing the National Library of Medicine using the keywords: 2D/3D echocardiography, strain, left/right ventricle, atrial, mitral/tricuspid valve, aorta, reference values/nomograms/normal values. Adding the following keywords, the results were further refined: range/intervals, myocardial velocity, strain rate and speckle tracking. Forty one published studies were included. Our study reveals that for several of 2D/3D parameters sufficient normative data exist, however, a few limitations still persist. For some basic parameters (i.e., mitral/tricuspid/pulmonary valves, great vessels) and for 3D valves data are scarce. There is a lack of studies evaluating ethnic differences. Data have been generally expressed as mean values normalised for gender and age instead of computing models incorporating different variables (age/gender/body sizes) to calculate z scores. To summarize results a software ( Echocardio-Normal Values ) who automatically calculate range of normality for a broad range of echocardiographic measurements according to age/gender/weight/height, has been generated. We provide an up-to-date and critical review of strengths/limitation of current adult echocardiographic nomograms. Furthermore we generated a software for automatic, easy and fast access to multiple echocardiographic normative data.

  1. Quantification of biventricular myocardial function using cardiac magnetic resonance feature tracking, endocardial border delineation and echocardiographic speckle tracking in patients with repaired tetralogy of fallot and healthy controls

    Science.gov (United States)

    2012-01-01

    Background Parameters of myocardial deformation have been suggested to be superior to conventional measures of ventricular function in patients with tetralogy of Fallot (ToF), but have required non-routine, tagged cardiovascular magnetic resonance (CMR) techniques. We assessed biventricular myocardial function using CMR cine-based feature tracking (FT) and compared it to speckle tracking echocardiography (STE) and to simple endocardial border delineation (EBD). In addition, the relation between parameters of myocardial deformation and clinical parameters was assessed. Methods Overall, 28 consecutive adult patients with repaired ToF (age 40.4 ± 13.3 years) underwent standard steady-state-free precession sequence CMR, echocardiography, and cardiopulmonary exercise testing. In addition, 25 healthy subjects served as controls. Myocardial deformation was assessed by CMR based FT (TomTec Diogenes software), CMR based EBD (using custom written software) and STE (TomTec Cardiac Performance Analysis software). Results Feature tracking was feasible in all subjects. A close agreement was found between measures of global left (LV) and right ventricular (RV) global strain. Interobserver agreement for FT and STE was similar for longitudinal LV global strain, but FT showed better inter-observer reproducibility than STE for circumferential or radial LV and longitudinal RV global strain. Reproducibility of regional strain on FT was, however, poor. The relative systolic length change of the endocardial border measured by EBD yielded similar results to FT global strain. Clinically, biventricular longitudinal strain on FT was reduced compared to controls (P < 0.0001) and was related to the number of previous cardiac operations. In addition, FT derived RV strain was related to exercise capacity and VE/VCO2-slope. Conclusions Although neither the inter-study reproducibility nor accuracy of FT software were investigated, and its inter-observer reproducibility for regional

  2. Gestational changes in left ventricular myocardial contractile function: new insights from two-dimensional speckle tracking echocardiography.

    Science.gov (United States)

    Sengupta, Shantanu P; Bansal, Manish; Hofstra, Leonard; Sengupta, Partho P; Narula, Jagat

    2017-01-01

    The goal of this study was to evaluate the impact of pregnancy and labor on left ventricular (LV) myocardial mechanics using speckle tracking echocardiography (STE). Pregnancy is characterized by profound hormonal and hemodynamic alterations that directly or indirectly influence cardiac structure and function. However, the impact of these changes on left ventricular (LV) myocardial contractile function has not been fully elucidated. In this prospective, longitudinal study, 35 pregnant women underwent serial clinical and echocardiographic evaluation during each trimester and at labor. Two dimensional STE was performed to measure global LV longitudinal, circumferential and radial strain (GLS, GCS and GRS, respectively). Similar data obtained from 20 nulliparous, age-matched women were used as control. All strain values during pregnancy were adjusted for age and hemodynamic parameters. There was a progressive increase in heart rate, systolic and diastolic blood pressure, cardiac output and LV stroke-work during pregnancy. LV end-diastolic and end-systolic volumes also increased progressively but LV ejection fraction remained unaltered, except for slight reduction during the second trimester. Compared to the controls, GLS and GCS were reduced in the first trimester itself (GLS -22.39 ± 5.43 % vs. -18.66 ± 0.64 %, P 0.0002; GCS -20.84 ± 3.20 vs. -17.88 ± 0.09, P counterbalancing changes in the myocardial mechanics. LV longitudinal and circumferential strain are reduced whereas radial strain is increased. These counterbalancing changes serve to maintain overall LV ejection performance within a normal range and enable the maternal heart to meet the hemodynamic demands of pregnancy and labor.

  3. Assessment of atrial fibrillation and vulnerability in patients with Wolff-Parkinson-White syndrome using two-dimensional speckle tracking echocardiography.

    Science.gov (United States)

    Li, Jing-Jie; Wei, Fang; Chen, Ju-Gang; Yu, Yan-Wei; Gu, Hong-Yue; Jiang, Rui; Wu, Xiu-Li; Sun, Qian

    2014-01-01

    The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both Psyndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period.

  4. Left ventricular torsion assessed by two-dimensional echocardiography speckle tracking as a predictor of left ventricular remodeling and short-term outcome following primary percutaneous coronary intervention for acute myocardial infarction: A single-center experience.

    Science.gov (United States)

    Awadalla, Hany; Saleh, Mohamed Ayman; Abdel Kader, Mohamed; Mansour, Amr

    2017-08-01

    Left ventricular (LV) torsion is a novel method to assess systolic LV function. This study aimed at exploring the utility of 2D speckle tracking-based assessment of left ventricular torsion in patients with acute myocardial infarction (AMI) undertaking primary percutaneous intervention (pPCI) in predicting left ventricular remodeling. The study included 115 patients (mean±SD, age 52.2±9.67, males 84.3%) who underwent pPCI for AMI. Echocardiographic assessment of LV torsion by two-dimensional speckle tracking was performed early after the index pPCI. Patients underwent repeat echocardiography at 6 months to detect remodeling. LV torsion in the acute setting was significantly lower in those who demonstrated LV remodeling at follow-up compared to those without remodeling (7.56±1.95 vs 15.16±4.65; P<.005). Multivariate analysis identified peak CK & CK-MB elevation (β=-0.767 and -0.725; P<.001), SWMA index (β=-0.843; P<.001), and Simpson's derived LV ejection fraction (LVEF; β=0.802; P<.001) as independent predictors of baseline LV torsion. It also identified peak LV torsion (β: 0.27; 95% CI: 0.15-0.5, P=.001) and SWMA index (β: 1.07, 95% CI: 1.03-1.12, P=.005) as independent predictors of LV remodeling. Baseline Killip's grades II and higher (β: 48.6; 95% CI 5.5-428, P<.001) and diabetes mellitus (β: 29.7; 95% CI 1.1-763, P<.05) were independent predictors of mortality. Left ventricular torsion in acute MI setting is impaired and predicts subsequent LV remodeling at 6-month follow-up. © 2017, Wiley Periodicals, Inc.

  5. Speckle tracking analysis: a new tool for left atrial function analysis in systemic hypertension: an overview.

    Science.gov (United States)

    Cameli, Matteo; Ciccone, Marco M; Maiello, Maria; Modesti, Pietro A; Muiesan, Maria L; Scicchitano, Pietro; Novo, Salvatore; Palmiero, Pasquale; Saba, Pier S; Pedrinelli, Roberto

    2016-05-01

    Speckle tracking echocardiography (STE) is an imaging technique applied to the analysis of left atrial function. STE provides a non-Doppler, angle-independent and objective quantification of left atrial myocardial deformation. Data regarding feasibility, accuracy and clinical applications of left atrial strain are rapidly gathering. This review describes the fundamental concepts of left atrial STE, illustrates its pathophysiological background and discusses its emerging role in systemic arterial hypertension.

  6. Three-dimensional Speckle Tracking Echocardiography in Light Chain Cardiac Amyloidosis: Examination of Left and Right Ventricular Myocardial Mechanics Parameters.

    Science.gov (United States)

    Urbano-Moral, Jose Angel; Gangadharamurthy, Dakshin; Comenzo, Raymond L; Pandian, Natesa G; Patel, Ayan R

    2015-08-01

    The study of myocardial mechanics has a potential role in the detection of cardiac involvement in patients with amyloidosis. This study aimed to characterize 3-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics in light chain amyloidosis and examine their relationship with brain natriuretic peptide. In patients with light chain amyloidosis, left ventricular longitudinal and circumferential strain (n=40), and right ventricular longitudinal strain and radial displacement (n=26) were obtained by 3-dimensional-speckle tracking echocardiography. Brain natriuretic peptide levels were determined. All myocardial mechanics measurements showed differences when compared by brain natriuretic peptide level tertiles. Left and right ventricular longitudinal strain were highly correlated (r=0.95, P<.001). Left ventricular longitudinal and circumferential strain were reduced in patients with cardiac involvement (-9±4 vs -16±2; P<.001, and -24±6 vs -29±4; P=.01, respectively), with the most prominent impairment at the basal segments. Right ventricular longitudinal strain and radial displacement were diminished in patients with cardiac involvement (-9±3 vs -17±3; P<.001, and 2.7±0.8 vs 3.8±0.3; P=.002). On multivariate analysis, left ventricular longitudinal strain was associated with the presence of cardiac involvement (odds ratio = 1.6; 95% confidence interval, 1.04 to 2.37; P=.03) independent of the presence of brain natriuretic peptide and troponin I criteria for cardiac amyloidosis. Three-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics are increasingly altered as brain natriuretic peptide increases in light chain amyloidosis. There appears to be a strong association between left ventricular longitudinal strain and cardiac involvement, beyond biomarkers such as brain natriuretic peptide and troponin I. Copyright © 2015 Sociedad Española de Cardiología. Published by

  7. Myocardial function in long distance runners: Assessment by echocardiography, tissue Doppler and speckle tracking

    OpenAIRE

    Pons, Jaume; Forteza, Josep Francesc; Riverso, Daniel; Aceña, Marta; Rodriguez, Antonio; Gómez, Alfredo; Fernández-Palomeque, Carlos; Bethencourt, Armando

    2014-01-01

    Introducción y objetivos: El ejercicio físico provoca respuestas adaptativas y cambios morfológico-funcionales en el corazón del atleta. El objetivo del presente estudio es caracterizar dichos cambios mediante ecocardiografía convencional y las nuevas técnicas de deformación miocárdica mediante speckle tracking. Material y métodos: Se estudiaron prospectivamente a 68 varones, 38 corredores de fondo (42±8 años), y 30 controles (40±7 años). Se les realizó estudio ecocardiográfico convencional m...

  8. Abnormal biventricular performance in asymptomatic adolescents late after repaired Tetralogy of Fallot: Combined two-dimensional speckle tracking and three-dimensional echocardiography study

    Directory of Open Access Journals (Sweden)

    Ken-Pen Weng

    2018-02-01

    Conclusion: Our results suggest asymptomatic adolescents with repaired TOF had abnormal biventricular myocardial performance, as demonstrated by combined 2D speckle-tracking and 3D echocardiography. The implications of these findings for management of adolescents late after repaired TOF remain to be determined.

  9. Left ventricular rigid body rotation in a diffuse large B-cell lymphoma patient with cardiac involvement: A case from the three-dimensional speckle-tracking echocardiographic MAGYAR-Path Study.

    Science.gov (United States)

    Földeák, Dóra; Kalapos, Anita; Domsik, Péter; Sinkó, Mária; Szeleczki, Nóra; Bagdi, Enikő; Krenács, László; Forster, Tamás; Borbényi, Zita; Nemes, Attila

    2017-02-01

    Secondary myocardial involvement by diffuse large B-cell lymphoma is a rare occurrence. Left ventricular (LV) twist is considered an essential part of LV function. In normal circumstances LV twist results from the movement of two orthogonally oriented muscular bands of a helical myocardial structure with consequent clockwise rotation of the base and counterclockwise rotation of the apex. Three-dimensional (3D) speckle-tracking echocardiography (3DSTE) has been found to be feasible for non-invasive 3D quantification of LV wall motion and rotational mechanics. The present report aimed to assess LV twisting motion in a patient with diffuse large B-cell lymphoma with positron emission tomography/computer tomography-proven cardiac involvement by 3DSTE. During 3DSTE, reduction in some segmental radial, longitudinal, circumferential, area and 3D LV strains were found. Apical and basal LV rotations were found to be in the same counterclockwise direction, confirming near absence of LV twist - so-called rigid body rotation. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Energy Technology Data Exchange (ETDEWEB)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L [Clinical Physics Laboratory-833, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); De Boode, W P [Neonatology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Huisman, H J [Department of Radiology, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands); Kapusta, L [Pediatric Cardiology, Department of Pediatrics, Radboud University Nijmegen Medical Centre, Nijmegen (Netherlands)], E-mail: m.m.nillesen@cukz.umcn.nl

    2009-04-07

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  11. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    International Nuclear Information System (INIS)

    Nillesen, M M; Lopata, R G P; Gerrits, I H; Thijssen, J M; De Korte, C L; De Boode, W P; Huisman, H J; Kapusta, L

    2009-01-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  12. In vivo validation of cardiac output assessment in non-standard 3D echocardiographic images

    Science.gov (United States)

    Nillesen, M. M.; Lopata, R. G. P.; de Boode, W. P.; Gerrits, I. H.; Huisman, H. J.; Thijssen, J. M.; Kapusta, L.; de Korte, C. L.

    2009-04-01

    Automatic segmentation of the endocardial surface in three-dimensional (3D) echocardiographic images is an important tool to assess left ventricular (LV) geometry and cardiac output (CO). The presence of speckle noise as well as the nonisotropic characteristics of the myocardium impose strong demands on the segmentation algorithm. In the analysis of normal heart geometries of standardized (apical) views, it is advantageous to incorporate a priori knowledge about the shape and appearance of the heart. In contrast, when analyzing abnormal heart geometries, for example in children with congenital malformations, this a priori knowledge about the shape and anatomy of the LV might induce erroneous segmentation results. This study describes a fully automated segmentation method for the analysis of non-standard echocardiographic images, without making strong assumptions on the shape and appearance of the heart. The method was validated in vivo in a piglet model. Real-time 3D echocardiographic image sequences of five piglets were acquired in radiofrequency (rf) format. These ECG-gated full volume images were acquired intra-operatively in a non-standard view. Cardiac blood flow was measured simultaneously by an ultrasound transit time flow probe positioned around the common pulmonary artery. Three-dimensional adaptive filtering using the characteristics of speckle was performed on the demodulated rf data to reduce the influence of speckle noise and to optimize the distinction between blood and myocardium. A gradient-based 3D deformable simplex mesh was then used to segment the endocardial surface. A gradient and a speed force were included as external forces of the model. To balance data fitting and mesh regularity, one fixed set of weighting parameters of internal, gradient and speed forces was used for all data sets. End-diastolic and end-systolic volumes were computed from the segmented endocardial surface. The cardiac output derived from this automatic segmentation was

  13. Realistic Vendor-Specific Synthetic Ultrasound Data for Quality Assurance of 2-D Speckle Tracking Echocardiography: Simulation Pipeline and Open Access Database.

    Science.gov (United States)

    Alessandrini, Martino; Chakraborty, Bidisha; Heyde, Brecht; Bernard, Olivier; De Craene, Mathieu; Sermesant, Maxime; D'Hooge, Jan

    2018-03-01

    Two-dimensional (2-D) echocardiography is the modality of choice in the clinic for the diagnosis of cardiac disease. Hereto, speckle tracking (ST) packages complement visual assessment by the cardiologist by providing quantitative diagnostic markers of global and regional cardiac function (e.g., displacement, strain, and strain-rate). Yet, the reported high vendor-dependence between the outputs of different ST packages raises clinical concern and hampers the widespread dissemination of the ST technology. In part, this is due to the lack of a solid commonly accepted quality assurance pipeline for ST packages. Recently, we have developed a framework to benchmark ST algorithms for 3-D echocardiography by using realistic simulated volumetric echocardiographic recordings. Yet, 3-D echocardiography remains an emerging technology, whereas the compelling clinical concern is, so far, directed to the standardization of 2-D ST only. Therefore, by building upon our previous work, we present in this paper a pipeline to generate realistic synthetic sequences for 2-D ST algorithms. Hereto, the synthetic cardiac motion is obtained from a complex electromechanical heart model, whereas realistic vendor-specific texture is obtained by sampling a real clinical ultrasound recording. By modifying the parameters in our pipeline, we generated an open-access library of 105 synthetic sequences encompassing: 1) healthy and ischemic motion patterns; 2) the most common apical probe orientations; and 3) vendor-specific image quality from seven different systems. Ground truth deformation is also provided to allow performance analysis. The application of the provided data set is also demonstrated in the benchmarking of a recent academic ST algorithm.

  14. Computer vision elastography: speckle adaptive motion estimation for elastography using ultrasound sequences.

    Science.gov (United States)

    Revell, James; Mirmehdi, Majid; McNally, Donal

    2005-06-01

    We present the development and validation of an image based speckle tracking methodology, for determining temporal two-dimensional (2-D) axial and lateral displacement and strain fields from ultrasound video streams. We refine a multiple scale region matching approach incorporating novel solutions to known speckle tracking problems. Key contributions include automatic similarity measure selection to adapt to varying speckle density, quantifying trajectory fields, and spatiotemporal elastograms. Results are validated using tissue mimicking phantoms and in vitro data, before applying them to in vivo musculoskeletal ultrasound sequences. The method presented has the potential to improve clinical knowledge of tendon pathology from carpel tunnel syndrome, inflammation from implants, sport injuries, and many others.

  15. Left Ventricular Myocardial Deformation Parameters Are Affected by Coronary Slow Flow Phenomenon: A Study of Speckle Tracking Echocardiography.

    Science.gov (United States)

    Gulel, Okan; Akcay, Murat; Soylu, Korhan; Aksan, Gokhan; Yuksel, Serkan; Zengin, Halit; Meric, Murat; Sahin, Mahmut

    2016-05-01

    The coronary slow flow phenomenon (CSFP) is defined as a delayed distal vessel contrast opacification in the absence of obstructive epicardial coronary artery disease during coronary angiography. There is conflicting data in medical literature regarding the effects of CSFP on the left ventricular functions assessed by conventional echocardiography or tissue Doppler imaging. Therefore, we aimed to evaluate whether there is any abnormality in the myocardial deformation parameters (strain, strain rate (SR), rotation, twist) of the left ventricle obtained by speckle tracking echocardiography (STE) in patients with CSFP. Twenty patients with CSFP were included prospectively in the study. Another 20 patients with similar demographics and cardiovascular risk factors as well as normal coronary angiography were used as the control group. Two-dimensional echocardiographic images of the left ventricle from the apical long-axis, two-chamber, four-chamber, and parasternal short-axis views were used for STE analysis. The analysis of left ventricular circumferential deformation parameters showed that the averaged peak systolic strain, systolic SR, and early diastolic SR values were significantly lower in patients with CSFP (P = 0.009, P = 0.02, and P = 0.02, respectively). Among the left ventricular rotation and twist values, apical rotation was significantly lower in patients with CSFP (P = 0.02). Further, the mean thrombolysis in myocardial infarction frame count value was found to be negatively correlated with the averaged peak circumferential early diastolic SR (r = -0.35, P = 0.03). It was positively correlated with the averaged peak circumferential systolic strain (r = 0.47, P = 0.003) and circumferential systolic SR (r = 0.46, P = 0.005). Coronary slow flow phenomenon leads to significant alterations in the myocardial deformation parameters of the left ventricle as assessed by STE. Specifically, circumferential deformation parameters are affected in CSFP patients. © 2015

  16. Determination of multidirectional myocardial deformations in cats with hypertrophic cardiomyopathy by using two-dimensional speckle-tracking echocardiography.

    Science.gov (United States)

    Suzuki, Ryohei; Mochizuki, Yohei; Yoshimatsu, Hiroki; Teshima, Takahiro; Matsumoto, Hirotaka; Koyama, Hidekazu

    2017-12-01

    Objectives Hypertrophic cardiomyopathy, a primary disorder of the myocardium, is the most common cardiac disease in cats. However, determination of myocardial deformation with two-dimensional speckle-tracking echocardiography in cats with various stages of hypertrophic cardiomyopathy has not yet been reported. This study was designed to measure quantitatively multidirectional myocardial deformations of cats with hypertrophic cardiomyopathy. Methods Thirty-two client-owned cats with hypertrophic cardiomyopathy and 14 healthy cats serving as controls were enrolled and underwent assessment of myocardial deformation (peak systolic strain and strain rate) in the longitudinal, radial and circumferential directions. Results Longitudinal and radial deformations were reduced in cats with hypertrophic cardiomyopathy, despite normal systolic function determined by conventional echocardiography. Cats with severely symptomatic hypertrophic cardiomyopathy also had lower peak systolic circumferential strain, in addition to longitudinal and radial strain. Conclusions and relevance Longitudinal and radial deformation may be helpful in the diagnosis of hypertrophic cardiomyopathy. Additionally, the lower circumferential deformation in cats with severe hypertrophic cardiomyopathy may contribute to clinical findings of decompensation, and seems to be related to severe cardiac clinical signs. Indices of multidirectional myocardial deformations by two-dimensional speckle-tracking echocardiography may be useful markers and help to distinguish between cats with hypertrophic cardiomyopathy and healthy cats. Additionally, they may provide more detailed assessment of contractile function in cats with hypertrophic cardiomyopathy.

  17. Breast cancer early detection via tracking of skin back-scattered secondary speckle patterns

    Science.gov (United States)

    Bennett, Aviya; Sirkis, Talia; Beiderman, Yevgeny; Agdarov, Sergey; Beiderman, Yafim; Zalevsky, Zeev

    2018-02-01

    Breast cancer has become a major cause of death among women. The lifetime risk of a woman developing this disease has been established as one in eight. The most useful way to reduce breast cancer death is to treat the disease as early as possible. The existing methods of early diagnostics of breast cancer are mainly based on screening mammography or Magnetic Resonance Imaging (MRI) periodically conducted at medical facilities. In this paper the authors proposing a new approach for simple breast cancer detection. It is based on skin stimulation by sound waves, illuminating it by laser beam and tracking the reflected secondary speckle patterns. As first approach, plastic balls of different sizes were placed under the skin of chicken breast and detected by the proposed method.

  18. 3D Characterization of corneal deformation using ultrasound speckle tracking

    Directory of Open Access Journals (Sweden)

    Keyton Clayson

    2017-11-01

    Full Text Available The three-dimensional (3D mechanical response of the cornea to intraocular pressure (IOP elevation has not been previously reported. In this study, we use an ultrasound speckle tracking technique to measure the 3D displacements and strains within the central 5.5mm of porcine corneas during the whole globe inflation. Inflation tests were performed on dextran-treated corneas (treated with a 10% dextran solution and untreated corneas. The dextran-treated corneas showed an inflation response expected of a thin spherical shell, with through-thickness thinning and in-plane stretch, although the strain magnitudes exhibited a heterogeneous spatial distribution from the central to more peripheral cornea. The untreated eyes demonstrated a response consistent with swelling during experimentation, with through-thickness expansion overriding the inflation response. The average volume ratios obtained in both groups was near 1 confirming general incompressibility, but local regions of volume loss or expansion were observed. These results suggest that biomechanical measurements in 3D provide important new insight to understand the mechanical response of ocular tissues such as the cornea.

  19. Speckle reduction in echocardiography by temporal compounding and anisotropic diffusion filtering

    Science.gov (United States)

    Giraldo-Guzmán, Jader; Porto-Solano, Oscar; Cadena-Bonfanti, Alberto; Contreras-Ortiz, Sonia H.

    2015-01-01

    Echocardiography is a medical imaging technique based on ultrasound signals that is used to evaluate heart anatomy and physiology. Echocardiographic images are affected by speckle, a type of multiplicative noise that obscures details of the structures, and reduces the overall image quality. This paper shows an approach to enhance echocardiography using two processing techniques: temporal compounding and anisotropic diffusion filtering. We used twenty echocardiographic videos that include one or three cardiac cycles to test the algorithms. Two images from each cycle were aligned in space and averaged to obtain the compound images. These images were then processed using anisotropic diffusion filters to further improve their quality. Resultant images were evaluated using quality metrics and visual assessment by two medical doctors. The average total improvement on signal-to-noise ratio was up to 100.29% for videos with three cycles, and up to 32.57% for videos with one cycle.

  20. 2D speckle tracking echocardiography of the right ventricle free wall in SCUBA divers after single open sea dive.

    Science.gov (United States)

    Susilovic-Grabovac, Zora; Obad, Ante; Duplančić, Darko; Banić, Ivana; Brusoni, Denise; Agostoni, Piergiuseppe; Vuković, Ivica; Dujic, Zeljko; Bakovic, Darija

    2018-03-01

    The presence of circulating gas bubbles and their influence on pulmonary and right heart hemodynamics was reported after uncomplicated self-contained underwater breathing apparatus (SCUBA) dive(s). Improvements in cardiac imaging have recently focused great attention on the right ventricle (RV). The aim of our study was to evaluate possible effects of a single air SCUBA dive on RV function using 2D speckle tracking echocardiography in healthy divers after single open sea dive to 18 meters of seawater, followed by bottom stay of 47 minutes with a direct ascent to the surface. Twelve experienced male divers (age 39.5 ± 10.5 years) participated in the study. Echocardiographic assessment of the right ventricular function (free wall 2 D strain, tricuspid annular planes systolic excursion [TAPSE], lateral tricuspid annular peak systolic velocity [RV s`] and fractional area change [FAC]) was performed directly prior to and 30, 60, 90 and 120 minutes after surfacing. Two-dimensional strain of all three segments of free right ventricular wall showed a significant increase in longitudinal shortening in post-dive period for maximally 26% (basal), 15.4% (mid) and 16.3% (apical) as well as TAPSE (11.6%), RV FAC (19.2%), RV S` (12.7%) suggesting a rise in systolic function of right heart. Mean pulmonary arterial pressure (mean PAP) increased post-dive from 13.3 mmHg to maximally 23.5 mmHg (P = .002), indicating increased RV afterload. Our results demonstrated that single dive with significant bubble load lead to increase in systolic function and longitudinal strain of the right heart in parallel with increase in mean PAP. © 2017 John Wiley & Sons Australia, Ltd.

  1. Right heart function in impaired left ventricular diastolic function: 2D speckle tracking echocardiography-based and Doppler tissue imaging-based analysis of right atrial and ventricular function.

    Science.gov (United States)

    Brand, Anna; Bathe, Marny; Oertelt-Prigione, Sabine; Seeland, Ute; Rücke, Mirjam; Regitz-Zagrosek, Vera; Stangl, Karl; Knebel, Fabian; Stangl, Verena; Dreger, Henryk

    2018-01-01

    The aim of our study was to describe right atrial (RA) and right ventricular (RV) function, assessed by Doppler tissue imaging and 2D speckle tracking echocardiography (2DSTE), in women with signs of early impaired left ventricular diastolic function (DD). In a cross-sectional trial, standard parameters of diastolic and right heart function were investigated in 438 women of the Berlin Female Risk Evaluation (BEFRI) study. In a subset of women, average peak systolic RA strain (RAS), as well as the average peak systolic RV strain of the free wall (RVS free wall) and of all RV segments (average RV strain; RVS Avg), was analyzed using 2DSTE. Compared to women with normal diastolic function (DD0), RAS, RVS free wall and RVS Avg were significantly reduced in DD (43.1% ± 11.9%, -26.7% ± 5.6%, and -23.3% ± 3.5% in DD0; vs 35.1% ± 10.4%, -23.9% ± 5.5%, and -20.6% ± 3.8% in DD; P right heart function is significantly altered in DD. DTI as well as 2DSTE constitute sensitive echocardiographic tools that enable the diagnosis of impaired right heart mechanics in early-staged DD. © 2017 Wiley Periodicals, Inc.

  2. Evaluation of right atrial dysfunction in patients with corrected tetralogy of Fallot using 3D speckle-tracking echocardiography. Insights from the CSONGRAD Registry and MAGYAR-Path Study.

    Science.gov (United States)

    Nemes, Attila; Havasi, Kálmán; Domsik, Péter; Kalapos, Anita; Forster, Tamás

    2015-11-01

    In recent studies, alterations in ventricular deformations were demonstrated in adult patients with corrected tetralogy of Fallot by three-dimensional speckle-tracking echocardiography. The present study was designed to assess three-dimensional speckle-tracking echocardiography-derived right atrial volumetric and strain parameters in corrected tetralogy of Fallot. A total of 17 patients with corrected tetralogy of Fallot were included in the study. Their results were compared with 18 age- and gender-matched healthy controls. Complete two-dimensional echocardiography and three-dimensional speckle-tracking echocardiography were performed in all cases. Significantly increased right atrial volumes respecting heart cycle were detected in patients with corrected tetralogy of Fallot. Total and passive atrial emptying fractions proved to be significantly decreased in patients with corrected tetralogy of Fallot (26.4 ± 12.4 % vs. 39.1 ± 8.8 %, p = 0.001 and 11.2 ± 6.8 % vs. 19.8 ± 9.0 %, p = 0.003, respectively). Global and mean segmental peak longitudinal (17.3 ± 9.2 % vs. 30.8 ± 11.2 %, p = 0.0007 and 20.6 ± 10.7 % vs. 34.4 ± 10.5 %, p = 0.0005) and area strains (20.1 ± 17.6 % vs. 41.0 ± 19.8 %, p = 0.004 and 28.1 ± 19.8 % vs. 49.1 ± 19.7 %, p = 0.004) as well as global radial peak strain (-9.1 ± 5.1 % vs. -15.0 ± 10.0 %, p = 0.05) were reduced in patients with corrected tetralogy of Fallot compared with controls. The complexity of right atrial dysfunction can be demonstrated by three-dimensional speckle-tracking echocardiography in patients with corrected tetralogy of Fallot.

  3. Fractional order integration and fuzzy logic based filter for denoising of echocardiographic image.

    Science.gov (United States)

    Saadia, Ayesha; Rashdi, Adnan

    2016-12-01

    Ultrasound is widely used for imaging due to its cost effectiveness and safety feature. However, ultrasound images are inherently corrupted with speckle noise which severely affects the quality of these images and create difficulty for physicians in diagnosis. To get maximum benefit from ultrasound imaging, image denoising is an essential requirement. To perform image denoising, a two stage methodology using fuzzy weighted mean and fractional integration filter has been proposed in this research work. In stage-1, image pixels are processed by applying a 3 × 3 window around each pixel and fuzzy logic is used to assign weights to the pixels in each window, replacing central pixel of the window with weighted mean of all neighboring pixels present in the same window. Noise suppression is achieved by assigning weights to the pixels while preserving edges and other important features of an image. In stage-2, the resultant image is further improved by fractional order integration filter. Effectiveness of the proposed methodology has been analyzed for standard test images artificially corrupted with speckle noise and real ultrasound B-mode images. Results of the proposed technique have been compared with different state-of-the-art techniques including Lsmv, Wiener, Geometric filter, Bilateral, Non-local means, Wavelet, Perona et al., Total variation (TV), Global Adaptive Fractional Integral Algorithm (GAFIA) and Improved Fractional Order Differential (IFD) model. Comparison has been done on quantitative and qualitative basis. For quantitative analysis different metrics like Peak Signal to Noise Ratio (PSNR), Speckle Suppression Index (SSI), Structural Similarity (SSIM), Edge Preservation Index (β) and Correlation Coefficient (ρ) have been used. Simulations have been done using Matlab. Simulation results of artificially corrupted standard test images and two real Echocardiographic images reveal that the proposed method outperforms existing image denoising techniques

  4. Normal left ventricular mechanics by two-dimensional speckle-tracking echocardiography. Reference values in healthy adults.

    Science.gov (United States)

    Kocabay, Gonenc; Muraru, Denisa; Peluso, Diletta; Cucchini, Umberto; Mihaila, Sorina; Padayattil-Jose, Seena; Gentian, Denas; Iliceto, Sabino; Vinereanu, Dragos; Badano, Luigi P

    2014-08-01

    Two-dimensional speckle-tracking echocardiography is a novel tool to assess myocardial function. The purpose of this study was to evaluate left ventricular myocardial strain and rotation parameters by two-dimensional speckle-tracking echocardiography in a large group of healthy adults across a wide age range to establish their reference values and to assess the influence of age, sex, and hemodynamic factors. Transthoracic echocardiograms were acquired in 247 healthy volunteers (139 women, 44 years [standard deviation, 16 years old] (range, 18-80 years). We measured longitudinal, circumferential, and radial peak systolic strain values, and left ventricular rotation and twist. Average values of global longitudinal, radial, and circumferential strain were -21.5% (standard deviation, 2.0%), 40.1% (standard deviation, 11.8%) and -22.2% (standard deviation, 3.4%), respectively. Longitudinal strain was significantly more negative in women, whereas radial and circumferential strain and rotational parameters were similar in both sexes. Accordingly, lower limits of normality for the strain components were -16.9% in men and -18.5% in women for longitudinal strain, and -15.4% for circumferential and 24.6% for radial strain, irrespective of sex. Longitudinal strain values were more negative at the base than at apical segments. Mean rotational values were -6.9° (standard deviation, 3.5°) for the base, 13.0° (standard deviation, 6.5°) for apical rotation, and 20.0° (standard deviation, 7.3°) for net twist. We report the comprehensive assessment of normal myocardial deformation and rotational mechanics in a large cohort of healthy volunteers. We found that women have more negative longitudinal strain, accounting for their higher left ventricular ejection fraction. Availability of reference values for these parameters may foster their implementation in the clinical routine. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  5. Changes in cardiac function and structure in newly diagnosed Graves' disease. A conventional and 2D-speckle tracking echocardiography study.

    Science.gov (United States)

    Aroditis, K; Pikilidou, M; Vourvouri, E; Hadjistavri, L; Zebekakis, P; Yovos, J; Efthimiadis, G; Karvounis, H

    2017-02-01

    Overproduction of thyroid hormones leads to structural as well as functional cardiac changes. Conventional echocardiography but also recently developed sophisticated two-dimensional echocardiography speckle (2D-STE) tracking allow elaborate evaluation of these changes. Our purpose was to investigate the effects of thyroid hormones overproduction on the heart in patients with Graves' disease and changes that occur after 6 months thyrostatic therapy. We conducted a prospective, case-control study of 6 months duration. Full echocardiographic assessment at diagnosis and after 6 months of thyrostatic therapy were performed in 44 patients with Graves' disease, aged 37.6 ± 9.1 years. Additionally, 43 euthyroid controls were studied for the same time period. Left ventricular end diastolic diameter (LVEDD) and left ventricular end systolic diameter (LVESD) were higher in the patient group while triscupid annular plane systolic excursion (TAPSE) was lower in the patient group. Moreover, left ventricular (LV) mass index and left atrium (LA) volume index were higher in the Graves' disease group. Diastolic impairment as assessed with conventional echocardiography including tissue Doppler was present in the patient group (E/A ratio 0.87 ± 0.10,). 2D-STE analysis, revealed an increase in the strain rate at the isovolumic relaxation time (SRIVRT, 0.310 ± 0.07 patients versus 0.298 ± 0.09 s -1 controls). Improvement in diastolic and right systolic function as well as in left ventricular structural parameters was observed after restoration of euthyroidism (E/A ratio from 0.87 ± 0.10 versus 0.9 ± 0.08, p < 0.05). Patients with newly diagnosed Graves' showed an improvement in diastolic function, right systolic function and structural parameters after 6 months of thyrostatic treatment.

  6. Early Impairment of Cardiac Function and Asynchronization of Systemic Amyloidosis with Preserved Ejection Fraction Using Two-Dimensional Speckle Tracking Echocardiography.

    Science.gov (United States)

    Huang, He; Jing, Xian-chao; Hu, Zhang-xue; Chen, Xi; Liu, Xiao-qin

    2015-12-01

    To observe the ventricular global and regional function of the patients with systemic amyloidosis using two-dimensional speckle tracking echocardiography. The study enrolled 31 consecutive biopsy-proved patients with systemic amyloidosis who underwent echocardiographic examination and EF ≥ 55% and 37 age- and gender-matched healthy controls. We compared systolic strain and strain rate, diastolic strain rate, time to peak strain, peak delay time in longitudinal, radial, circumferential directions in 16 left ventricular segments. The global peak systolic longitudinal and radial strain of left ventricle, peak systolic longitudinal strain and strain rate, diastolic strain rate of right ventricular free wall were also compared. (1) Global peak systolic longitudinal strain (GPSLS), peak systolic longitudinal strain (PSLS) and strain rate (PSLSR), peak early diastolic longitudinal strain rate (PELSR) in 16 segments were decreased in case (P < 0.05). (2) Peak systolic radial strain and strain rate of inferoseptum and inferolateral at the level of papillary muscle were lower (P < 0.05), and peak early diastolic radial strain rate (PERSR) was reduced (P < 0.05). (3) Peak early diastolic circumferential strain rate was lower (P < 0.05). (4) Time to peak systolic longitudinal, radial, circumferential strain was longer, and peak delay time at the same level retarded (P < 0.05). (5) Into right ventricular wall, PSLS and PSLSR at mid-segment, and PSLSR, PELSR, peak atrial systolic longitudinal strain rate (PALSR) at basal were reduced (P < 0.05). (6) Inverse correlation between interventricular septum (IVS) thickness and GPSLS and GPSRS was found (P < 0.05). Systolic and diastolic dysfunction existed in systemic amyloidosis with preserved EF. Mechanical contraction disorder may be one reason for systolic dysfunction. GPLSR and GPRSR were negatively related to IVS thickness. © 2015, Wiley Periodicals, Inc.

  7. Modeled and Measured Partially Coherent Illumination Speckle Effects from Sloped Surfaces for Tactical Tracking

    Science.gov (United States)

    2015-03-26

    the number of speckle samples obtained, laser power and coherence length, spot size, target reflectance, speckle size, and pixels per speckle width...gated imaging systems,” Proc. SPIE, 6542: 654218, April 2007. 90 St. Pierre, Randall J. and others. “Active Tracker Laser (ATLAS),” IEEE J. Sel...numerical model developed here and existing theory developed by Hu. A 671 nm diode laser source with coherence length of 259 +/- 7 µm is reflected

  8. Speckle Interferometry

    Science.gov (United States)

    Chiang, F. P.; Jin, F.; Wang, Q.; Zhu, N.

    Before the milestone work of Leedertz in 1970 coherent speckles generated from a laser illuminated object are considered noise to be eliminated or minimized. Leedertz shows that coherent speckles are actually information carriers. Since then the speckle technique has found many applications to fields of mechanics, metrology, nondestructive evaluation and material sciences. Speckles need not be coherent. Artificially created socalled white light speckles can also be used as information carriers. In this paper we present two recent developments of speckle technique with applications to micromechanics problems using SIEM (Speckle Interferometry with Electron Microscopy), to nondestructive evaluation of crevice corrosion and composite disbond and vibration of large structures using TADS (Time-Average Digital Specklegraphy).

  9. Cognitive Machine-Learning Algorithm for Cardiac Imaging: A Pilot Study for Differentiating Constrictive Pericarditis From Restrictive Cardiomyopathy.

    Science.gov (United States)

    Sengupta, Partho P; Huang, Yen-Min; Bansal, Manish; Ashrafi, Ali; Fisher, Matt; Shameer, Khader; Gall, Walt; Dudley, Joel T

    2016-06-01

    Associating a patient's profile with the memories of prototypical patients built through previous repeat clinical experience is a key process in clinical judgment. We hypothesized that a similar process using a cognitive computing tool would be well suited for learning and recalling multidimensional attributes of speckle tracking echocardiography data sets derived from patients with known constrictive pericarditis and restrictive cardiomyopathy. Clinical and echocardiographic data of 50 patients with constrictive pericarditis and 44 with restrictive cardiomyopathy were used for developing an associative memory classifier-based machine-learning algorithm. The speckle tracking echocardiography data were normalized in reference to 47 controls with no structural heart disease, and the diagnostic area under the receiver operating characteristic curve of the associative memory classifier was evaluated for differentiating constrictive pericarditis from restrictive cardiomyopathy. Using only speckle tracking echocardiography variables, associative memory classifier achieved a diagnostic area under the curve of 89.2%, which improved to 96.2% with addition of 4 echocardiographic variables. In comparison, the area under the curve of early diastolic mitral annular velocity and left ventricular longitudinal strain were 82.1% and 63.7%, respectively. Furthermore, the associative memory classifier demonstrated greater accuracy and shorter learning curves than other machine-learning approaches, with accuracy asymptotically approaching 90% after a training fraction of 0.3 and remaining flat at higher training fractions. This study demonstrates feasibility of a cognitive machine-learning approach for learning and recalling patterns observed during echocardiographic evaluations. Incorporation of machine-learning algorithms in cardiac imaging may aid standardized assessments and support the quality of interpretations, particularly for novice readers with limited experience. © 2016

  10. Left Ventricular Deformation by Speckle Tracking Echocardiography at 2-year Follow-up in Treatment Naive Rheumatoid Arthritis Patients

    DEFF Research Database (Denmark)

    Løgstrup, Brian Bridal; Masic, D; Laurberg, Trine Bay

    2015-01-01

    -CCP titers were evaluated by standardized techniques at baseline and 2-year follow-up. We performed a novel advanced echocardiography by speckle tracking in means of global LV systolic deformation (GLS) imaging. One experienced senior rheumatologist and one experienced cardiologist performed all the clinical...... assessments as well as all the echocardiography including the LV deformation analysis at baseline and by 2-year follow-up. Results: Disease activity scores before treatment at baseline and at 2-year follow-up were respectively: number of swollen joints (28): 7.1+/-2.9 (SD) and 0.4+/-0.3, number of tender...

  11. Assessment of inter-atrial, inter-ventricular, and atrio-ventricular interactions in tetralogy of Fallot patients after surgical correction. Insights from two-dimensional speckle tracking and three-dimensional echocardiography.

    Science.gov (United States)

    Abd El Rahman, Mohamed; Raedle-Hurst, Tanja; Rentzsch, Axel; Schäfers, Hans-Joachim; Abdul-Khaliq, Hashim

    2015-10-01

    We aimed to assess biatrial size and function, interactions on atrial and ventricular levels, and atrio-ventricular coupling in patients after tetralogy of Fallot repair. A total of 34 patients with a mean age of 20.9±9 years, and 35 healthy controls, underwent two-dimensional speckle tracking echocardiography for ventricular and atrial strain measurements and real-time three-dimensional echocardiography to assess ventricular and atrial volumes. When compared with controls, tetralogy of Fallot patients had significantly reduced right atrial peak atrial longitudinal strain (ptetralogy of Fallot group, left ventricular ejection fraction was negatively related to the right ventricular end-systolic volume normalised to body surface area (r=-0.62, ptetralogy of Fallot patients, biatrial dysfunction exists and can be quantified via two-dimensional speckle tracking echocardiography as well as real-time three-dimensional echocardiography. Different forms of interactions on atrial and ventricular levels are evident among such cohorts.

  12. Assessment of strain and strain rate by two-dimensional speckle tracking in mice: comparison with tissue Doppler echocardiography and conductance catheter measurements.

    Science.gov (United States)

    Ferferieva, V; Van den Bergh, A; Claus, P; Jasaityte, R; La Gerche, A; Rademakers, F; Herijgers, P; D'hooge, J

    2013-08-01

    This study was designed in order to compare the strain and strain rate deformation parameters assessed by speckle tracking imaging (STI) with those of tissue Doppler imaging (TDI) and conductance catheter measurements in chronic murine models of left ventricular (LV) dysfunction. Twenty-four male C57BL/6J mice were assigned to wild-type (n = 8), myocardial infarction (n = 8) and transaortic constriction (n = 8) groups. Echocardiographic and conductance measurements were simultaneously performed at rest and during dobutamine infusion (5 µg/kg/min) in all animals 10 weeks post-surgery. The LV circumferential strain (Scirc) and the strain rate (SRcirc) were derived from grey scale and tissue Doppler data at frame rates of 224 and 375 Hz, respectively. Scirc and SRcirc by TDI/STI correlated well with the preload recruitable stroke work (PRSW) (r = -0.64 and -0.71 for TDI; r = -0.46 and -0.50 for STI, P < 0.05). Both modalities showed a good agreement with respect to Scirc and SRcirc (r = 0.60 and r = 0.63, P < 0.05). During stress, however, TDI-estimated Scirc and SRcirc values were predominantly higher than those measured by STI (P < 0.05). The similarity of Scirc and SRcirc measurements with respect to the STI/TDI data was examined by the Bland-Altman analysis. In mice, the STI- and TDI-derived strain and strain rate deformation parameters relate closely to intrinsic myocardial function. At low heart rate-to-frame rate ratios (HR/FR), both STI and TDI are equally acceptable for assessing the LV function non-invasively in these animals. At HR/FR (e.g. dobutamine challenge), however, these methods cannot be used interchangeably as STI underestimates S and SR at high values.

  13. Left Ventricular Function in Patients with Pulmonary Arterial Hypertension: The Role of Two-Dimensional Speckle Tracking Strain.

    Science.gov (United States)

    de Amorim Corrêa, Ricardo; de Oliveira, Fernanda Brito; Barbosa, Marcia M; Barbosa, Jose Augusto A; Carvalho, Taís Soares; Barreto, Michele Campos; Campos, Frederico Thadeu A F; Nunes, Maria Carmo Pereira

    2016-09-01

    Pulmonary arterial hypertension (PAH) is characterized by elevated mean pulmonary arterial pressure with abnormal right ventricular (RV) pressure overload that may alter left ventricular (LV) function. The aim of this study was to assess the impact of RV pressure overload on LV function in PAH patients using two-dimensional (2D) speckle tracking strain. The study enrolled 37 group 1 PAH patients and 38 age- and gender-matched healthy controls. LV longitudinal and radial 2D strains were measured with and without including the ventricular septum. Six-minute walk test (6MWT) and brain natriuretic peptide (BNP) levels were also obtained in patients with PAH. The mean age of patients was 46.4 ± 14.8 years, 76% women, and 16 patients (43%) had schistosomiasis. Sixteen patients (43%) were in WHO class III or IV under specific treatment for PAH. The overall 6MWT distance was 441 meters, and the BNP levels were 80 pg/mL. Patients with PAH more commonly presented with LV diastolic dysfunction and impairment of RV function when compared to controls. LV global longitudinal and radial strains were lower in patients than in controls (-17.9 ± 2.8 vs. -20.5 ± 1.9; P < 0.001 and 30.8 ± 10.5 vs. 49.8 ± 15.4; P < 0.001, respectively). After excluding septal values, LV longitudinal and radial strains remained lower in patients than in controls. The independent factors associated with global LV longitudinal strain were LV ejection fraction, RV fractional area change, and tricuspid annular systolic motion. This study showed impaired LV contractility in patients with PAH assessed by speckle tracking strain, irrespective of ventricular septal involvement. Global LV longitudinal strain was associated independently with RV fractional area change and tricuspid annular systolic motion, after adjustment for LV ejection fraction. © 2016, Wiley Periodicals, Inc.

  14. Development of left ventricular longitudinal speckle tracking echocardiography in very low birth weight infants with and without bronchopulmonary dysplasia during the neonatal period.

    Directory of Open Access Journals (Sweden)

    Christoph Czernik

    Full Text Available OBJECTIVES: In preterm infants, postnatal myocardial adaptation may be complicated by bronchopulmonary dysplasia (BPD. We aimed to describe the development of left ventricular function by serial 2D, Doppler, and speckle tracking echocardiography (2D-STE in infants with and without BPD during the neonatal period and compare these to anthropometric and conventional hemodynamic parameters. STUDY DESIGN: Prospective echocardiography on day of life (DOL 1, 7, 14, and 28 in 119 preterm infants 10% were seen for the apical segment. While anthropometric parameters show rapid development during the first 4 weeks of life, the speckle tracking parameters did not differ statistically significantly during the neonatal period. Infants with and without BPD differed significantly (p<0.001 in the development of anthropometric parameters, conventional hemodynamic parameters except for heart rate, and 2D-STE parameters: global longitudinal systolic strain rate (GLSSR and longitudinal systolic strain for the mid left wall (LSSR. The largest differences were seen at DOL 1 and 7 in GLSSR (p<0.001 and in LSSR (p<0.01. CONCLUSIONS: Reproducible 2D-STE measurements are possible in preterm infants <1500 g. Cardiac deformation reveals early (DOL 1 and 7 ventricular changes (GLSSR and LSSR in very low birth weight infants who develop BPD.

  15. Measurement of left ventricular torsion using block-matching-based speckle tracking for two-dimensional echocardiography

    Science.gov (United States)

    Sun, Feng-Rong; Wang, Xiao-Jing; Wu, Qiang; Yao, Gui-Hua; Zhang, Yun

    2013-01-01

    Left ventricular (LV) torsion is a sensitive and global index of LV systolic and diastolic function, but how to noninvasively measure it is challenging. Two-dimensional echocardiography and the block-matching based speckle tracking method were used to measure LV torsion. Main advantages of the proposed method over the previous ones are summarized as follows: (1) The method is automatic, except for manually selecting some endocardium points on the end-diastolic frame in initialization step. (2) The diamond search strategy is applied, with a spatial smoothness constraint introduced into the sum of absolute differences matching criterion; and the reference frame during the search is determined adaptively. (3) The method is capable of removing abnormal measurement data automatically. The proposed method was validated against that using Doppler tissue imaging and some preliminary clinical experimental studies were presented to illustrate clinical values of the proposed method.

  16. Assessment of atrial fibrillation and vulnerability in patients with Wolff-Parkinson-White syndrome using two-dimensional speckle tracking echocardiography.

    Directory of Open Access Journals (Sweden)

    Jing-Jie Li

    Full Text Available PURPOSE: The aim was to assess atrial fibrillation (AF and vulnerability in Wolff-Parkinson-White (WPW syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE. METHODS: All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. RESULTS: Results showed significant differences in both body mass index (BMI and supraventricular tachycardia (SVT duration between WPW patients and DAVNP patients (both P<0.05. Echocardiography revealed that the maximum left atrial volume (LAVmax and the left ventricular mass index (LVMI in diastole increased noticeably in patients with WPW compared to patients with DAVNP both before and after ablation (all P<0.05. Before ablation, there were obvious differences in the levels of SRs, SRe, and SRa from the 4-chamber view (LA in the WPW patients group compared with patients in the DAVNP group (all P<0.05. In the AF group, there were significant differences in the levels of systolic strain rate (SRs, early diastolic strain rate (SRe, and late diastolic strain rate (SRa from the 4-chamber view (LA both before and after ablation (all P<0.05. In the non-AF group, there were decreased SRe levels from the 4-chamber view (LA/RA pre-ablation compared to post-ablation (all P<0.05. CONCLUSION: Our findings provide convincing evidence that WPW syndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period.

  17. Potential of the McMath-Pierce 1.6-Meter Solar Telescope for Speckle Interferometry

    Science.gov (United States)

    Harshaw, Richard; Jones, Gregory; Wiley, Edward; Boyce, Patrick; Branston, Detrick; Rowe, David; Genet, Russell

    2015-09-01

    We explored the aiming and tracking accuracy of the McMath-Pierce 1.6 m solar telescope at Kitt Peak National Observatory as part of an investigation of using this telescope for speckle interferometry of close visual double stars. Several slews of various lengths looked for hysteresis in the positioning system (we found none of significance) and concluded that the 1.6 m telescope would make a useful telescope for speckle interferometry.

  18. Simulations of x-ray speckle-based dark-field and phase-contrast imaging with a polychromatic beam

    Energy Technology Data Exchange (ETDEWEB)

    Zdora, Marie-Christine, E-mail: marie-christine.zdora@diamond.ac.uk [Lehrstuhl für Biomedizinische Physik, Physik-Department & Institut für Medizintechnik, Technische Universität München, 85748 Garching (Germany); Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom); Department of Physics & Astronomy, University College London, London WC1E 6BT (United Kingdom); Thibault, Pierre [Department of Physics & Astronomy, University College London, London WC1E 6BT (United Kingdom); Pfeiffer, Franz [Lehrstuhl für Biomedizinische Physik, Physik-Department & Institut für Medizintechnik, Technische Universität München, 85748 Garching (Germany); Zanette, Irene [Lehrstuhl für Biomedizinische Physik, Physik-Department & Institut für Medizintechnik, Technische Universität München, 85748 Garching (Germany); Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2015-09-21

    Following the first experimental demonstration of x-ray speckle-based multimodal imaging using a polychromatic beam [I. Zanette et al., Phys. Rev. Lett. 112(25), 253903 (2014)], we present a simulation study on the effects of a polychromatic x-ray spectrum on the performance of this technique. We observe that the contrast of the near-field speckles is only mildly influenced by the bandwidth of the energy spectrum. Moreover, using a homogeneous object with simple geometry, we characterize the beam hardening artifacts in the reconstructed transmission and refraction angle images, and we describe how the beam hardening also affects the dark-field signal provided by speckle tracking. This study is particularly important for further implementations and developments of coherent speckle-based techniques at laboratory x-ray sources.

  19. Quantification of global myocardial function by cine MRI deformable registration-based analysis: Comparison with MR feature tracking and speckle-tracking echocardiography

    International Nuclear Information System (INIS)

    Lamacie, Mariana M.; Thavendiranathan, Paaladinesh; Hanneman, Kate; Greiser, Andreas; Jolly, Marie-Pierre; Ward, Richard; Wintersperger, Bernd J.

    2017-01-01

    To evaluate deformable registration algorithms (DRA)-based quantification of cine steady-state free-precession (SSFP) for myocardial strain assessment in comparison with feature-tracking (FT) and speckle-tracking echocardiography (STE). Data sets of 28 patients/10 volunteers, undergoing same-day 1.5T cardiac MRI and echocardiography were included. LV global longitudinal (GLS), circumferential (GCS) and radial (GRS) peak systolic strain were assessed on cine SSFP data using commercially available FT algorithms and prototype DRA-based algorithms. STE was applied as standard of reference for accuracy, precision and intra-/interobserver reproducibility testing. DRA showed narrower limits of agreement compared to STE for GLS (-4.0 [-0.9,-7.9]) and GCS (-5.1 [1.1,-11.2]) than FT (3.2 [11.2,-4.9]; 3.8 [13.9,-6.3], respectively). While both DRA and FT demonstrated significant differences to STE for GLS and GCS (all p<0.001), only DRA correlated significantly to STE for GLS (r=0.47; p=0.006). However, good correlation was demonstrated between MR techniques (GLS:r=0.74; GCS:r=0.80; GRS:r=0.45, all p<0.05). Comparing DRA with FT, intra-/interobserver coefficient of variance was lower (1.6 %/3.2 % vs. 6.4 %/5.7 %) and intraclass-correlation coefficient was higher. DRA GCS and GRS data presented zero variability for repeated observations. DRA is an automated method that allows myocardial deformation assessment with superior reproducibility compared to FT. (orig.)

  20. Quantification of global myocardial function by cine MRI deformable registration-based analysis: Comparison with MR feature tracking and speckle-tracking echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Lamacie, Mariana M. [University Health Network, Department of Medical Imaging, Toronto, Ontario (Canada); Thavendiranathan, Paaladinesh [University Health Network, Department of Medical Imaging, Toronto, Ontario (Canada); University of Toronto, Department of Medicine, Division of Cardiology, Toronto, Ontario (Canada); Hanneman, Kate [University Health Network, Department of Medical Imaging, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Greiser, Andreas [Siemens Healthcare, Erlangen (Germany); Jolly, Marie-Pierre [Medical Imaging Technologies, Siemens Healthcare, Princeton, NJ (United States); Ward, Richard [University of Toronto, Department of Medicine, Division of Cardiology, Toronto, Ontario (Canada); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-04-15

    To evaluate deformable registration algorithms (DRA)-based quantification of cine steady-state free-precession (SSFP) for myocardial strain assessment in comparison with feature-tracking (FT) and speckle-tracking echocardiography (STE). Data sets of 28 patients/10 volunteers, undergoing same-day 1.5T cardiac MRI and echocardiography were included. LV global longitudinal (GLS), circumferential (GCS) and radial (GRS) peak systolic strain were assessed on cine SSFP data using commercially available FT algorithms and prototype DRA-based algorithms. STE was applied as standard of reference for accuracy, precision and intra-/interobserver reproducibility testing. DRA showed narrower limits of agreement compared to STE for GLS (-4.0 [-0.9,-7.9]) and GCS (-5.1 [1.1,-11.2]) than FT (3.2 [11.2,-4.9]; 3.8 [13.9,-6.3], respectively). While both DRA and FT demonstrated significant differences to STE for GLS and GCS (all p<0.001), only DRA correlated significantly to STE for GLS (r=0.47; p=0.006). However, good correlation was demonstrated between MR techniques (GLS:r=0.74; GCS:r=0.80; GRS:r=0.45, all p<0.05). Comparing DRA with FT, intra-/interobserver coefficient of variance was lower (1.6 %/3.2 % vs. 6.4 %/5.7 %) and intraclass-correlation coefficient was higher. DRA GCS and GRS data presented zero variability for repeated observations. DRA is an automated method that allows myocardial deformation assessment with superior reproducibility compared to FT. (orig.)

  1. Functional assessment of the diaphragm by speckle tracking ultrasound during inspiratory loading

    NARCIS (Netherlands)

    Mos-Oppersma, Eline; Hatam, Nima; Doorduin, Jonne; van der Hoeven, Johannes G.; Marx, Gernot; Goetzenich, Andreas; Fritsch, Sebastian; Heunks, Leo M.A.; Bruells, Christian S.

    2017-01-01

    Assessment of diaphragmatic effort is challenging, especially in critically ill patients in the phase of weaning. Fractional thickening during inspiration assessed by ultrasound has been used to estimate diaphragm effort. It is unknown whether more sophisticated ultrasound techniques such as speckle

  2. Prognosis of Light Chain Amyloidosis With Preserved LVEF: Added Value of 2D Speckle-Tracking Echocardiography to the Current Prognostic Staging System.

    Science.gov (United States)

    Barros-Gomes, Sergio; Williams, Brittney; Nhola, Lara F; Grogan, Martha; Maalouf, Joseph F; Dispenzieri, Angela; Pellikka, Patricia A; Villarraga, Hector R

    2017-04-01

    This study evaluated whether 2-dimensional speckle-tracking echocardiography (2D-STE) has incremental value for prognosis over traditional clinical, echocardiographic, and serological markers-with main focus on the current prognostic staging system-in light-chain (AL) amyloidosis patients with preserved left ventricular ejection fraction. Cardiac amyloidosis (CA) is the major determinant of outcome in AL amyloidosis. The current prognostic staging system is based primarily on serum levels of cardiac troponin T (cTnT), N-terminal pro-B-type natriuretic peptide (NT-proBNP), and free light chain differential (FLC-diff). Consecutive patients with biopsy-proven AL amyloidosis and left ventricular ejection fraction ≥55% were divided into group 1 with CA (n = 63) and group 2 without CA (n = 87). Global longitudinal strain (GLS) by 2D-STE was performed with Vivid E9 (GE Healthcare Co., Milwaukee, Wisconsin) and syngo Velocity Vector Imaging (VVI) software (Siemens Medical Solutions USA, Inc., Malvern, Pennsylvania) (GLS GE and GLS VVI , respectively). Thirty-two deaths (51%) occurred in group 1 and 13 (15%) in group 2 (p ≤ 0.001). Group 1 had thicker walls, lower early diastolic tissue Doppler velocity at septal mitral annulus, and greater left ventricular mass, left atrial volume, glomerular filtration rate, FLC-diff, cTnT, and NT-proBNP (p value over cTnT, NT-proBNP, and FLC-diff. For survival analysis limited to group 2 (non-CA), GLS GE and GLS VVI both predicted all-cause mortality (GLS GE HR: 1.23; 95% CI: 1.03 to 1.47 [p = 0.02]; GLS VVI HR: 1.22; 95% CI: 1.01 to 1.49 [p = 0.04], respectively). 2D-STE predicted outcome and provided incremental prognostic information over the current prognostic staging system, especially in the group without CA. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Clinical feasibility and validation of 3D principal strain analysis from cine MRI: comparison to 2D strain by MRI and 3D speckle tracking echocardiography.

    Science.gov (United States)

    Satriano, Alessandro; Heydari, Bobak; Narous, Mariam; Exner, Derek V; Mikami, Yoko; Attwood, Monica M; Tyberg, John V; Lydell, Carmen P; Howarth, Andrew G; Fine, Nowell M; White, James A

    2017-12-01

    Two-dimensional (2D) strain analysis is constrained by geometry-dependent reference directions of deformation (i.e. radial, circumferential, and longitudinal) following the assumption of cylindrical chamber architecture. Three-dimensional (3D) principal strain analysis may overcome such limitations by referencing intrinsic (i.e. principal) directions of deformation. This study aimed to demonstrate clinical feasibility of 3D principal strain analysis from routine 2D cine MRI with validation to strain from 2D tagged cine analysis and 3D speckle tracking echocardiography. Thirty-one patients undergoing cardiac MRI were studied. 3D strain was measured from routine, multi-planar 2D cine SSFP images using custom software designed to apply 4D deformation fields to 3D cardiac models to derive principal strain. Comparisons of strain estimates versus those by 2D tagged cine, 2D non-tagged cine (feature tracking), and 3D speckle tracking echocardiography (STE) were performed. Mean age was 51 ± 14 (36% female). Mean LV ejection fraction was 66 ± 10% (range 37-80%). 3D principal strain analysis was feasible in all subjects and showed high inter- and intra-observer reproducibility (ICC range 0.83-0.97 and 0.83-0.98, respectively-p analysis is feasible using routine, multi-planar 2D cine MRI and shows high reproducibility with strong correlations to 2D conventional strain analysis and 3D STE-based analysis. Given its independence from geometry-related directions of deformation this technique may offer unique benefit for the detection and prognostication of myocardial disease, and warrants expanded investigation.

  4. Entendue invariance in speckle fields

    International Nuclear Information System (INIS)

    Medina, F.F.; Garcia-Sucerquia, J.; Henao, R.; Trivi, M.

    2000-04-01

    Experimental evidence is shown that confirms the Entendue invariance in speckle fields. Because of this condition, the coherence patch of the speckle field can be significantly greater than the mean size of the speckles, as is shown by double exposure speckle interferometry. (author)

  5. Assessment of Subclinical Doxorubicin-induced Cardiotoxicity in a Rat Model by Speckle-Tracking Imaging.

    Science.gov (United States)

    Kang, Yu; Wang, Wei; Zhao, Hang; Qiao, Zhiqing; Shen, Xuedong; He, Ben

    2017-07-10

    Despite their clear therapeutic benefits, anthracycline-induced cardiotoxicity is a major concern limiting the ability to reduce morbidity and mortality associated with cancers. The early identification of anthracycline-induced cardiotoxicity is of vital importance to assess the cardiac risk against the potential cancer treatment. To investigate whether speckle-tracking analysis can provide a sensitive and accurate measurement when detecting doxorubicin-induced left ventricular injury. Wistar rats were divided into 4 groups with 8 rats each, given doxorubicin intraperitoneally at weekly intervals for up to 4 weeks. Group 1: 2.5 mg/kg/week; group 2: 3 mg/kg/week; group 3: 3.5mg/kg/week; group 4: 4mg/kg/week. An additional 5 rats were used as controls. Echocardiographic images were obtained at baseline and 1 week after the last dose of treatment. Radial (Srad) and circumferential (Scirc) strains, radial (SRrad) and circumferential (SRcirc) strain rates were analyzed. After the experiment, cardiac troponin I (cTnI) was analyzed and the heart samples were histologically evaluated. After doxorubicin exposure, LVEF was significantly reduced in group 4 (p = 0.006), but remained stable in the other groups. However, after treatment, Srads were reduced in groups 2, 3 and 4 (p all grupos de 8 ratos cada, e doxorrubicina foi administrada intraperitonealmente em intervalos semanais de até 4 semanas. Grupo 1: 2,5 mg/kg/semana; Grupo 2: 3 mg/kg/semana; Grupo 3: 3,5 mg/kg/semana; Grupo 4: 4 mg/kg/semana. Foram utilizados 5 ratos adicionais como controles. As imagens ecocardiográficas foram obtidas na linha basal e 1 semana após a última dose do tratamento. Foram analisados o strain radial (Srad) e circunferencial (Scirc) e as taxas de strain radial (TSrad) e circunferencial (TScirc). Após o experimento, a troponina cardíaca I (cTnI) foi analisada e as amostras cardíacas foram avaliadas histologicamente. Após a exposição à doxorrubicina, a FEVE foi significativamente

  6. Postsystolic Shortening by Speckle Tracking Echocardiography Is an Independent Predictor of Cardiovascular Events and Mortality in the General Population

    DEFF Research Database (Denmark)

    Brainin, Philip; Biering-Sørensen, Sofie Reumert; Møgelvang, Rasmus

    2018-01-01

    BACKGROUND: Postsystolic shortening (PSS) has been proposed as a novel marker of contractile dysfunction in the myocardium. Our objective was to assess the prognostic potential of PSS on cardiovascular events and death in the general population. METHODS AND RESULTS: The study design consisted...... of a prospective cohort study of 1296 low-risk participants from the general population, who were examined by speckle tracking echocardiography. The primary end point was the composite of heart failure, myocardial infarction, and cardiovascular death, defined as major adverse cardiovascular events (MACEs...... as having MACEs and 236 participants (18%) died. Increasing number of walls with PSS predicted both end points, an association that persisted after adjustment for age, sex, estimated glomerular filtration rate, global longitudinal strain, hypertension, heart rate, left ventricular ejection fraction, LV mass...

  7. [Assessment of the right ventricular anatomy and function by advanced echocardiography: pathological and physiological insights].

    Science.gov (United States)

    Lakatos, Bálint; Kovács, Attila; Tokodi, Márton; Doronina, Alexandra; Merkely, Béla

    2016-07-01

    Accurate assessment of right ventricular geometry and function is of high clinical importance. However, several limitations have to be taken into consideration if using conventional echocardiographic parameters. Advanced echocardiographic techniques, such as speckle-tracking analysis or 3D echocardiography are reliable and simple tools providing a cost-effective and non-invasive alternative of current modalities used to characterize the right ventricle. There is a growing interest in the diagnostic and prognostic value of these methods regarding pathological (right ventricular infarction, pulmonary hypertension, arrhythmogenic right ventricular dysplasia, follow-up of heart transplantation) and even physiological (athlete's heart) alterations of the right ventricle. Orv. Hetil., 2016, 157(29), 1139-1146.

  8. Speckle interferometry

    Science.gov (United States)

    Sirohi, Rajpal S.

    2002-03-01

    Illumination of a rough surface by a coherent monochromatic wave creates a grainy structure in space termed a speckle pattern. It was considered a special kind of noise and was the bane of holographers. However, its information-carrying property was soon discovered and the phenomenon was used for metrological applications. The realization that a speckle pattern carried information led to a new measurement technique known as speckle interferometry (SI). Although the speckle phenomenon in itself is a consequence of interference among numerous randomly dephased waves, a reference wave is required in SI. Further, it employs an imaging geometry. Initially SI was performed mostly by using silver emulsions as the recording media. The double-exposure specklegram was filtered to extract the desired information. Since SI can be configured so as to be sensitive to the in-plane displacement component, the out-of-plane displacement component or their derivatives, the interferograms corresponding to these were extracted from the specklegram for further analysis. Since the speckle size can be controlled by the F number of the imaging lens, it was soon realized that SI could be performed with electronic detection, thereby increasing its accuracy and speed of measurement. Furthermore, a phase-shifting technique can also be incorporated. This technique came to be known as electronic speckle pattern interferometry (ESPI). It employed the same experimental configurations as SI. ESPI found many industrial applications as it supplements holographic interferometry. We present three examples covering diverse areas. In one application it has been used to measure residual stress in a blank recordable compact disk. In another application, microscopic ESPI has been used to study the influence of relative humidity on paint-coated figurines and also the effect of a conservation agent applied on top of this. The final application is to find the defects in pipes. These diverse applications

  9. Two-dimensional speckle-tracking strain echocardiography in long-term heart transplant patients: a study comparing deformation parameters and ejection fraction derived from echocardiography and multislice computed tomography.

    Science.gov (United States)

    Syeda, Bonni; Höfer, Peter; Pichler, Philipp; Vertesich, Markus; Bergler-Klein, Jutta; Roedler, Susanne; Mahr, Stephane; Goliasch, Georg; Zuckermann, Andreas; Binder, Thomas

    2011-07-01

    Longitudinal strain determined by speckle tracking is a sensitive parameter to detect systolic left ventricular dysfunction. In this study, we assessed regional and global longitudinal strain values in long-term heart transplants and compared deformation indices with ejection fraction as determined by transthoracic echocardiography (TTE) and multislice computed tomographic coronary angiography (MSCTA). TTE and MSCTA were prospectively performed in 31 transplant patients (10.6 years post-transplantation) and in 42 control subjects. Grey-scale apical views were recorded for speckle tracking (EchoPAC 7.0, GE) of the 16 segments of the left ventricle. The presence of coronary artery disease (CAD) was assessed by MSCTA. Strain analysis was performed in 1168 segments [496 in transplant patients (42.5%), 672 in control subjects (57.7%)]. Global longitudinal peak systolic strain was significantly lower in the transplant recipients than in the healthy population (-13.9 ± 4.2 vs. -17.4 ± 5.8%, PSimpsons method) was 60.7 ± 10.1%/60.2 ± 6.7% in transplant recipients vs. 64.7 ± 6.4%/63.0 ± 6.2% in the healthy population, P=ns. Even though 'healthy' heart transplants without CAD exhibit normal ejection fraction, deformation indices are reduced in this population when compared with control subjects. Our findings suggests that strain analysis is more sensitive than assessment of ejection fraction for the detection of abnormalities of systolic function.

  10. [Assessment of left ventricular twist in type 2 diabetes mellitus by using two-dimensional ultrasound speckle tracking imaging].

    Science.gov (United States)

    Zhu, Pei-hua; Huang, Jing-yuan; Ye, Meng; Zheng, Zhe-lan

    2014-09-01

    To evaluate the left ventricular twist characteristics in patients with type 2 diabetes by using two-dimensional speckle tracking imaging (STI). Ninety-three patients with type 2 diabetes admitted in Zhejiang Hospital from May 2012 to September 2013 were enrolled. According to left ventricular ejection fraction (LVEF), patients were divided into two groups: normal left ventricular systolic function group (group A, LVEF≥0.50, n=46) and abnormal left ventricular systolic function group (group B, LVEF Consistency check for STI was conducted to assess its stability and reliability. The Peaktw, AVCtw, and MVOtw in group A were significantly elevated than those in normal controls (Pconsistency limit=-2.8-2.7; within measurer: R=0.964, bias=-0.2, 95% consistency limits=-2.7-2.2). STI can be used for early recognition of abnormal changes of cardiac function in type 2 diabetic mellitus patients, with high stability and reliability.

  11. Added clinical value of applying myocardial deformation imaging to assess right ventricular function.

    Science.gov (United States)

    Sokalskis, Vladislavs; Peluso, Diletta; Jagodzinski, Annika; Sinning, Christoph

    2017-06-01

    Right heart dysfunction has been found to be a strong prognostic factor predicting adverse outcome in various cardiopulmonary diseases. Conventional echocardiographic measurements can be limited by geometrical assumptions and impaired reproducibility. Speckle tracking-derived strain provides a robust quantification of right ventricular function. It explicitly evaluates myocardial deformation, as opposed to tissue Doppler-derived strain, which is computed from tissue velocity gradients. Right ventricular longitudinal strain provides a sensitive tool for detecting right ventricular dysfunction, even at subclinical levels. Moreover, the longitudinal strain can be applied for prognostic stratification of patients with pulmonary hypertension, pulmonary embolism, and congestive heart failure. Speckle tracking-derived right atrial strain, right ventricular longitudinal strain-derived mechanical dyssynchrony, and three-dimensional echocardiography-derived strain are emerging imaging parameters and methods. Their application in research is paving the way for their clinical use. © 2017, Wiley Periodicals, Inc.

  12. Three-dimensional speckle tracking imaging assessment of left ventricular change in patient with coronary heart disease and its correlation with serum indexes

    Directory of Open Access Journals (Sweden)

    Jian-Li Fu

    2016-10-01

    Full Text Available Objective: To analyze the three-dimensional speckle tracking imaging assessment of left ventricular change in patient with coronary heart disease and its correlation with serum indexes. Methods: A total of 152 patients first diagnosed with coronary heart disease were the observation group of the study and 117 healthy subjects were the control group. Threedimensional speckle tracking imaging (3D-STI was used to evaluate the left ventricular function parameters of two groups, the serum content of endothelial function indexes and platelet function indexes were detected, and the correlation between left ventricular function parameters under 3D-STI and serum indexes was further analyzed. Results: Absolute values of left ventricular function parameters LVGLS, LVGRS, LVGCS and LVGAS from 3D-STI of observation group were significantly less than those of control group while Ptw and Torsion levels were greater than those of control group; endothelial function indexes vWF, sICAM-1, sVCAM-1 and ET-1 content in serum were significantly higher than those of control group while vWF-cp and NO content were significantly lower than those of control group; platelet function indexes CD62P, GMP-140, CD63, sP-selectin, sCD40L and PAC-1 content in serum were significantly higher than those of control group. The levels of left ventricular function parameters from 3D-STI in patients with coronary heart disease were directly correlated with serum indexes. Conclusion: 3D-STI can accurately assess the left ventricular function and the overall disease severity in patients with coronary heart disease, and it is expected to become an effective method for early diagnosis of diseases and guidance of clinical treatment.

  13. Digital Speckle Photography of Subpixel Displacements of Speckle Structures Based on Analysis of Their Spatial Spectra

    Science.gov (United States)

    Maksimova, L. A.; Ryabukho, P. V.; Mysina, N. Yu.; Lyakin, D. V.; Ryabukho, V. P.

    2018-04-01

    We have investigated the capabilities of the method of digital speckle interferometry for determining subpixel displacements of a speckle structure formed by a displaceable or deformable object with a scattering surface. An analysis of spatial spectra of speckle structures makes it possible to perform measurements with a subpixel accuracy and to extend the lower boundary of the range of measurements of displacements of speckle structures to the range of subpixel values. The method is realized on the basis of digital recording of the images of undisplaced and displaced speckle structures, their spatial frequency analysis using numerically specified constant phase shifts, and correlation analysis of spatial spectra of speckle structures. Transformation into the frequency range makes it possible to obtain quantities to be measured with a subpixel accuracy from the shift of the interference-pattern minimum in the diffraction halo by introducing an additional phase shift into the complex spatial spectrum of the speckle structure or from the slope of the linear plot of the function of accumulated phase difference in the field of the complex spatial spectrum of the displaced speckle structure. The capabilities of the method have been investigated in natural experiment.

  14. Left ventricular systolic dysfunction in asymptomatic Marfan syndrome patients is related to the severity of gene mutation: insights from the novel three dimensional speckle tracking echocardiography.

    Directory of Open Access Journals (Sweden)

    Mohamed Abd El Rahman

    Full Text Available In asymptomatic Marfan syndrome (MFS patients we evaluated the relationship between the types of fibrillin-1 (FBN1 gene mutation and possible altered left ventricular (LV function as assessed by three-dimensional speckle tracking echocardiography (3D-STE.Forty-five MFS patients (mean age 24 ± 15 years and 40 age-matched healthy controls were studied. Genetic evaluation for the FBN1 gene was carried on 32 MFS patients. Gene mutation (n = 15, 47% was classified as mild when the mutation resulted in nearly normally functioning protein, while mutations resulting in abnormally function protein were considered to be severe (n = 17, 53%. All patients and controls underwent 3D-STE for evaluation of LV function by an echocardiographer blinded to the results of the genetic testing. Compared to controls, MFS patients had significantly lower 3D-STE derived LV ejection fraction (EF, 57.43 ± 7.51 vs. 62.69 ± 4.76%, p = 0.0001, global LV longitudinal strain (LS, 14.85 ± 2.89 vs. 17.90 ± 2.01%, p = 0.0001, global LV circumferential strain (CS, 13.93 ± 2.81 vs. 16.82 ± 2.17%, p = 0.0001 and global LV area strain (AS, 25.76 ± 4.43 vs. 30.51 ± 2.61%, p = 0.0001. Apart from the global LV LS all these parameters were significantly lower in patients with severe gene mutation than in those with mild mutation (p < 0.05. In the multivariate linear regression analysis only the type of mutation had a significant influence on the 3D-STE derived LVEF (p = 0.017, global CS (p = 0.005 and global AS (p = 0.03.In asymptomatic MFS patients latent LV dysfunction can be detected using 3D STE. The LV dysfunction is mainly related to the severity of gene mutation, suggesting possible primary cardiomyopathy in MFS patients.

  15. Speckle-based spectrometer

    DEFF Research Database (Denmark)

    Chakrabarti, Maumita; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2015-01-01

    A novel spectrometer concept is analyzed and experimentally verified. The method relies on probing the speckle displacement due to a change in the incident wavelength. A rough surface is illuminated at an oblique angle, and the peak position of the covariance between the speckle patterns observed...

  16. Global Longitudinal Strain Using Speckle-Tracking Echocardiography as a Mortality Predictor in Sepsis: A Systematic Review.

    Science.gov (United States)

    Vallabhajosyula, Saraschandra; Rayes, Hamza A; Sakhuja, Ankit; Murad, Mohammad Hassan; Geske, Jeffrey B; Jentzer, Jacob C

    2018-01-01

    The data on speckle-tracking echocardiography (STE) in patients with sepsis are limited. This systematic review from 1975 to 2016 included studies in adults and children evaluating cardiovascular dysfunction in sepsis, severe sepsis, and septic shock utilizing STE for systolic global longitudinal strain (GLS). The primary outcome was short- or long-term mortality. Given the significant methodological and statistical differences between published studies, combining the data using meta-analysis methods was not appropriate. A total of 120 studies were identified, with 5 studies (561 patients) included in the final analysis. All studies were prospective observational studies using the 2001 criteria for defining sepsis. Three studies demonstrated worse systolic GLS to be associated with higher mortality, whereas 2 did not show a statistically significant association. Various cutoffs between -10% and -17% were used to define abnormal GLS across studies. This systematic review revealed that STE may predict mortality in patients with sepsis; however, the strength of evidence is low due to heterogeneity in study populations, GLS technologies, cutoffs, and timing of STE. Further dedicated studies are needed to understand the optimal application of STE in patients with sepsis.

  17. Development of Speckle Interferometry Algorithm and System

    International Nuclear Information System (INIS)

    Shamsir, A. A. M.; Jafri, M. Z. M.; Lim, H. S.

    2011-01-01

    Electronic speckle pattern interferometry (ESPI) method is a wholefield, non destructive measurement method widely used in the industries such as detection of defects on metal bodies, detection of defects in intergrated circuits in digital electronics components and in the preservation of priceless artwork. In this research field, this method is widely used to develop algorithms and to develop a new laboratory setup for implementing the speckle pattern interferometry. In speckle interferometry, an optically rough test surface is illuminated with an expanded laser beam creating a laser speckle pattern in the space surrounding the illuminated region. The speckle pattern is optically mixed with a second coherent light field that is either another speckle pattern or a smooth light field. This produces an interferometric speckle pattern that will be detected by sensor to count the change of the speckle pattern due to force given. In this project, an experimental setup of ESPI is proposed to analyze a stainless steel plate using 632.8 nm (red) wavelength of lights.

  18. Objective speckle velocimetry for autonomous vehicle odometry.

    Science.gov (United States)

    Francis, D; Charrett, T O H; Waugh, L; Tatam, R P

    2012-06-01

    Speckle velocimetry is investigated as a means of determining odometry data with potential for application on autonomous robotic vehicles. The technique described here relies on the integration of translation measurements made by normalized cross-correlation of speckle patterns to determine the change in position over time. The use of objective (non-imaged) speckle offers a number of advantages over subjective (imaged) speckle, such as a reduction in the number of optical components, reduced modulation of speckles at the edges of the image, and improved light efficiency. The influence of the source/detector configuration on the speckle translation to vehicle translation scaling factor for objective speckle is investigated using a computer model and verified experimentally. Experimental measurements are presented at velocities up to 80  mm s(-1) which show accuracy better than 0.4%.

  19. Speckle pattern processing by digital image correlation

    Directory of Open Access Journals (Sweden)

    Gubarev Fedor

    2016-01-01

    Full Text Available Testing the method of speckle pattern processing based on the digital image correlation is carried out in the current work. Three the most widely used formulas of the correlation coefficient are tested. To determine the accuracy of the speckle pattern processing, test speckle patterns with known displacement are used. The optimal size of a speckle pattern template used for determination of correlation and corresponding the speckle pattern displacement is also considered in the work.

  20. Speckle: Friend or foe?

    Science.gov (United States)

    Goodman, Joseph W.

    2013-05-01

    Speckle appears whenever coherent radiation of any kind is used. We review here the basic properties of speckle, the negative effects it has on imaging systems of various kinds, and the positive benefits it offers in certain nondestructive testing and metrology problems.

  1. Regional Longitudinal Deformation Improves Prediction of Ventricular Tachyarrhythmias in Patients With Heart Failure With Reduced Ejection Fraction

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Knappe, Dorit; Pouleur, Anne-Catherine

    2017-01-01

    BACKGROUND: Left ventricular dysfunction is a known predictor of ventricular arrhythmias. We hypothesized that measures of regional longitudinal deformation by speckle-tracking echocardiography predict ventricular tachyarrhythmias and provide incremental prognostic information over clinical...... in the model, only a decreasing myocardial function in the inferior myocardial wall predicted VT/VF (hazard ratio, 1.05 [1.00-1.11]; P=0.039). Only strain obtained from the inferior myocardial wall provided incremental prognostic information for VT/VF over clinical and echocardiographic parameters (C statistic...... 0.71 versus 0.69; P=0.005). CONCLUSIONS: Assessment of regional longitudinal myocardial deformation in the inferior region provided incremental prognostic information over clinical and echocardiographic risk factors in predicting ventricular tachyarrhythmias. CLINICAL TRIAL REGISTRATION: URL: http...

  2. Machine-Learning Algorithms to Automate Morphological and Functional Assessments in 2D Echocardiography.

    Science.gov (United States)

    Narula, Sukrit; Shameer, Khader; Salem Omar, Alaa Mabrouk; Dudley, Joel T; Sengupta, Partho P

    2016-11-29

    Machine-learning models may aid cardiac phenotypic recognition by using features of cardiac tissue deformation. This study investigated the diagnostic value of a machine-learning framework that incorporates speckle-tracking echocardiographic data for automated discrimination of hypertrophic cardiomyopathy (HCM) from physiological hypertrophy seen in athletes (ATH). Expert-annotated speckle-tracking echocardiographic datasets obtained from 77 ATH and 62 HCM patients were used for developing an automated system. An ensemble machine-learning model with 3 different machine-learning algorithms (support vector machines, random forests, and artificial neural networks) was developed and a majority voting method was used for conclusive predictions with further K-fold cross-validation. Feature selection using an information gain (IG) algorithm revealed that volume was the best predictor for differentiating between HCM ands. ATH (IG = 0.24) followed by mid-left ventricular segmental (IG = 0.134) and average longitudinal strain (IG = 0.131). The ensemble machine-learning model showed increased sensitivity and specificity compared with early-to-late diastolic transmitral velocity ratio (p 13 mm. In this subgroup analysis, the automated model continued to show equal sensitivity, but increased specificity relative to early-to-late diastolic transmitral velocity ratio, e', and strain. Our results suggested that machine-learning algorithms can assist in the discrimination of physiological versus pathological patterns of hypertrophic remodeling. This effort represents a step toward the development of a real-time, machine-learning-based system for automated interpretation of echocardiographic images, which may help novice readers with limited experience. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Strain and strain rate by two-dimensional speckle tracking echocardiography in a maned wolf

    Directory of Open Access Journals (Sweden)

    Matheus M. Mantovani

    2012-12-01

    Full Text Available The measurement of cardiovascular features of wild animals is important, as is the measurement in pets, for the assessment of myocardial function and the early detection of cardiac abnormalities, which could progress to heart failure. Speckle tracking echocardiography (2D STE is a new tool that has been used in veterinary medicine, which demonstrates several advantages, such as angle independence and the possibility to provide the early diagnosis of myocardial alterations. The aim of this study was to evaluate the left myocardial function in a maned wolf by 2D STE. Thus, the longitudinal, circumferential and radial strain and strain rate were obtained, as well as, the radial and longitudinal velocity and displacement values, from the right parasternal long axis four-chamber view, the left parasternal apical four chamber view and the parasternal short axis at the level of the papillary muscles. The results of the longitudinal variables were -13.52±7.88, -1.60±1.05, 4.34±2.52 and 3.86±3.04 for strain (%, strain rate (1/s, displacement (mm and velocity (cm/s, respectively. In addition, the radial and circumferential Strain and Strain rate were 24.39±14.23, 1.86±0.95 and -13.69±6.53, -1.01±0.48, respectively. Thus, the present study provides the first data regarding the use of this tool in maned wolves, allowing a more complete quantification of myocardial function in this species.

  4. Color speckle in laser displays

    Science.gov (United States)

    Kuroda, Kazuo

    2015-07-01

    At the beginning of this century, lighting technology has been shifted from discharge lamps, fluorescent lamps and electric bulbs to solid-state lighting. Current solid-state lighting is based on the light emitting diodes (LED) technology, but the laser lighting technology is developing rapidly, such as, laser cinema projectors, laser TVs, laser head-up displays, laser head mounted displays, and laser headlamps for motor vehicles. One of the main issues of laser displays is the reduction of speckle noise1). For the monochromatic laser light, speckle is random interference pattern on the image plane (retina for human observer). For laser displays, RGB (red-green-blue) lasers form speckle patterns independently, which results in random distribution of chromaticity, called color speckle2).

  5. Speckle perception and disturbance limit in laser based projectors

    Science.gov (United States)

    Verschaffelt, Guy; Roelandt, Stijn; Meuret, Youri; Van den Broeck, Wendy; Kilpi, Katriina; Lievens, Bram; Jacobs, An; Janssens, Peter; Thienpont, Hugo

    2016-04-01

    We investigate the level of speckle that can be tolerated in a laser cinema projector. For this purpose, we equipped a movie theatre room with a prototype laser projector. A group of 186 participants was gathered to evaluate the speckle perception of several, short movie trailers in a subjective `Quality of Experience' experiment. This study is important as the introduction of lasers in projection systems has been hampered by the presence of speckle in projected images. We identify a speckle disturbance threshold by statistically analyzing the observers' responses for different values of the amount of speckle, which was monitored using a well-defined speckle measurement method. The analysis shows that the speckle perception of a human observer is not only dependent on the objectively measured amount of speckle, but it is also strongly influenced by the image content. As is also discussed in [Verschaffelt et al., Scientific Reports 5, art. nr. 14105, 2015] we find that, for moving images, the speckle becomes disturbing if the speckle contrast becomes larger than 6.9% for the red, 6.0% for the green, and 4.8% for the blue primary colors of the projector, whereas for still images the speckle detection threshold is about 3%. As we could not independently tune the speckle contrast of each of the primary colors, this speckle disturbance limit seems to be determined by the 6.9% speckle contrast of the red color as this primary color contains the largest amount of speckle. The speckle disturbance limit for movies thus turns out to be substantially larger than that for still images, and hence is easier to attain.

  6. Early Detection of Subclinical Uremic Cardiomyopathy Using Two-Dimensional Speckle Tracking Echocardiography.

    Science.gov (United States)

    Hassanin, Noha; Alkemary, Alkhateeb

    2016-04-01

    Overhydration has a deleterious effect on cardio myocytes. This study was designated to evaluate left ventricular (LV) systolic and diastolic dysfunction in patients with various stages of chronic kidney disease (CKD) using conventional, tissue Doppler and two-dimensional speckle tracking echocardiography (2DSTE). Forty controls and 90 CKD patients, aged 49.3 ± 14 years old, were enrolled in the study. Patients were divided into 3 groups depending on their glomerular filtration rate. Group 1 (≥60 mL/min per 1.73 m(2) ), group 2 (≤60 mL/min per 1.73 m(2) ), and group 3 (≤60 mL/min per 1.73 m(2) and on regular dialysis for at least 12 months). Pulsed-Doppler and tissue Doppler studies were used to estimate LV filling pressure E/E'. Using 2DSTE, circumferential, radial, and longitudinal functions of the LV have been measured. LV longitudinal systolic strain, early, and late diastolic strain rates were significantly reduced in CKD patients (-16.9 ± 3.8%, 1.6 ± 0.5%, and 1.3 ± 0.4% in CKD vs. -22.5 ± 0.6%, 2.3 ± 0.2%, and 1.9 ± 0.1% in controls, P < 0.001 for all), and no difference was observed in terms of the circumferential LV functions (-22.4 ± 1.7 vs. -22.5 ± 1.4, P = 0.567). Severity of the kidney dysfunction appears to parallel with the rise of E/E' significantly (P < 0.001). In CKD, although the longitudinal and radial systolic functions were reduced, LV ejection fraction may remain within normal limits due to the preservation of the circumferential functions. Early detection of uremic cardiomyopathy might provide useful information for the risk stratification and decide the proper dialysis therapy in these patients. © 2015, Wiley Periodicals, Inc.

  7. Role of Three-Dimensional Speckle Tracking Echocardiography in the Quantification of Myocardial Iron Overload in Patients with Beta-Thalassemia Major.

    Science.gov (United States)

    Li, Shu-Juan; Hwang, Yu-Yan; Ha, Shau-Yin; Chan, Godfrey C F; Mok, Amanda S P; Wong, Sophia J; Cheung, Yiu-Fai

    2016-09-01

    The new three-dimensional speckle tracking echocardiography (3DSTE) may enable comprehensive quantification of global left ventricular (LV) myocardial mechanics. Twenty-four patients aged 29.3 ± 5.2 years and 22 controls were studied. 3DSTE was performed to assess LV 3D global strain, twist and torsion, ejection fraction, and systolic dyssynchrony index (SDI). The LV SDI was calculated as % of SD of times-to-peak strain of 16 segments/RR interval. The global performance index (GPI) was calculated as (global 3D strain·torsion)/SDI. Area under the receiver operating characteristic curve (AUC) was calculated to determine the capability of 3DSTE parameters to discriminate between patients with (cardiac magnetic resonance T2* overload. Compared with controls, patients had significantly lower LV global 3D strain (P overload. The LV composite index of strain, torsion, and dyssynchrony derived from 3DSTE enables sensitive detection of myocardial iron overload in patients with thalassemia. © 2016, Wiley Periodicals, Inc.

  8. Ice Velocity Mapping Using TOPS SAR Data and Offset Tracking

    DEFF Research Database (Denmark)

    Dall, Jørgen; Kusk, Anders; Nielsen, Ulrik

    2015-01-01

    Feature tracking and speckle tracking, are robust techniques to measure the velocity of glaciers and ice sheets. Displacement maps based on TOPS data may have small gaps if the bursts are not handled properly. Ice moving from one burst to a consecutive burst between two observations is not observ...

  9. Three-dimensional speckle tracking echocardiography allows detailed evaluation of left atrial function in hypertrophic cardiomyopathy--insights from the MAGYAR-Path Study.

    Science.gov (United States)

    Domsik, Péter; Kalapos, Anita; Chadaide, Számi; Sepp, Róbert; Hausinger, Péter; Forster, Tamás; Nemes, Attila

    2014-11-01

    Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three-dimensional (3D) speckle tracking echocardiography (STE) has just been introduced for the evaluation of LA. This study was designed to compare 3DSTE-derived LA volumetric and strain parameters in HCM with healthy controls. The study comprised 23 consecutive HCM patients (mean age: 48.5 ± 15.1 years, 14 men). Their results were compared to 23 age- and gender-matched healthy controls. Complete two-dimensional Doppler echocardiography and 3DSTE have been performed in all cases. Calculated LA maximum (66.4 ± 20.4 mL vs. 36.0 ± 6.1 mL, P echocardiography allows detailed evaluation of LA (dys) function in HCM by volumetric and strain measurements. © 2014, Wiley Periodicals, Inc.

  10. X-ray speckle correlation interferometer

    International Nuclear Information System (INIS)

    Eisenhower, Rachel; Materlik, Gerhard

    2000-01-01

    Speckle Pattern Correlation Interferometry (SPCI) is a well-established technique in the visible-light regime for observing surface disturbances. Although not a direct imaging technique, SPCI gives full-field, high-resolution information about an object's motion. Since x-ray synchrotron radiation beamlines with high coherent flux have allowed the observation of x-ray speckle, x-ray SPCI could provide a means to measure strains and other quasi-static motions in disordered systems. This paper therefore examines the feasibility of an x-ray speckle correlation interferometer

  11. Cardiac time intervals and the association with 2D-speckle-tracking, tissue Doppler and conventional echocardiography

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Jensen, Jan Skov; Andersen, Henrik Ullits

    2016-01-01

    Cardiac time intervals (CTI) are prognostic above and beyond conventional echocardiographic measures. The explanation may be that CTI contain information about both systolic and diastolic measures; this is, however, unknown. The relationship between the CTI and systolic and diastolic function...

  12. Blind Source Parameters for Performance Evaluation of Despeckling Filters

    Directory of Open Access Journals (Sweden)

    Nagashettappa Biradar

    2016-01-01

    Full Text Available The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI, and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink embedded with Stein’s unbiased risk estimation (SURE. The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  13. Blind Source Parameters for Performance Evaluation of Despeckling Filters.

    Science.gov (United States)

    Biradar, Nagashettappa; Dewal, M L; Rohit, ManojKumar; Gowre, Sanjaykumar; Gundge, Yogesh

    2016-01-01

    The speckle noise is inherent to transthoracic echocardiographic images. A standard noise-free reference echocardiographic image does not exist. The evaluation of filters based on the traditional parameters such as peak signal-to-noise ratio, mean square error, and structural similarity index may not reflect the true filter performance on echocardiographic images. Therefore, the performance of despeckling can be evaluated using blind assessment metrics like the speckle suppression index, speckle suppression and mean preservation index (SMPI), and beta metric. The need for noise-free reference image is overcome using these three parameters. This paper presents a comprehensive analysis and evaluation of eleven types of despeckling filters for echocardiographic images in terms of blind and traditional performance parameters along with clinical validation. The noise is effectively suppressed using the logarithmic neighborhood shrinkage (NeighShrink) embedded with Stein's unbiased risk estimation (SURE). The SMPI is three times more effective compared to the wavelet based generalized likelihood estimation approach. The quantitative evaluation and clinical validation reveal that the filters such as the nonlocal mean, posterior sampling based Bayesian estimation, hybrid median, and probabilistic patch based filters are acceptable whereas median, anisotropic diffusion, fuzzy, and Ripplet nonlinear approximation filters have limited applications for echocardiographic images.

  14. The SKED: speckle knife edge detector

    International Nuclear Information System (INIS)

    Sharpies, S D; Light, R A; Achamfuo-Yeboah, S O; Clark, M; Somekh, M G

    2014-01-01

    The knife edge detector—also known as optical beam deflection—is a simple and robust method of detecting ultrasonic waves using a laser. It is particularly suitable for detection of high frequency surface acoustic waves as the response is proportional to variation of the local tilt of the surface. In the case of a specular reflection of the incident laser beam from a smooth surface, any lateral movement of the reflected beam caused by the ultrasonic waves is easily detected by a pair of photodiodes. The major disadvantage of the knife edge detector is that it does not cope well with optically rough surfaces, those that give a speckled reflection. The optical speckles from a rough surface adversely affect the efficiency of the knife edge detector, because 'dark' speckles move synchronously with 'bright' speckles, and their contributions to the ultrasonic signal cancel each other out. We have developed a new self-adapting sensor which can cope with the optical speckles reflected from a rough surface. It is inelegantly called the SKED—speckle knife edge detector—and like its smooth surface namesake it is simple, cheap, compact, and robust. We describe the theory of its operation, and present preliminary experimental results validating the overall concept and the operation of the prototype device

  15. The SKED: speckle knife edge detector

    Science.gov (United States)

    Sharpies, S. D.; Light, R. A.; Achamfuo-Yeboah, S. O.; Clark, M.; Somekh, M. G.

    2014-06-01

    The knife edge detector—also known as optical beam deflection—is a simple and robust method of detecting ultrasonic waves using a laser. It is particularly suitable for detection of high frequency surface acoustic waves as the response is proportional to variation of the local tilt of the surface. In the case of a specular reflection of the incident laser beam from a smooth surface, any lateral movement of the reflected beam caused by the ultrasonic waves is easily detected by a pair of photodiodes. The major disadvantage of the knife edge detector is that it does not cope well with optically rough surfaces, those that give a speckled reflection. The optical speckles from a rough surface adversely affect the efficiency of the knife edge detector, because 'dark' speckles move synchronously with 'bright' speckles, and their contributions to the ultrasonic signal cancel each other out. We have developed a new self-adapting sensor which can cope with the optical speckles reflected from a rough surface. It is inelegantly called the SKED—speckle knife edge detector—and like its smooth surface namesake it is simple, cheap, compact, and robust. We describe the theory of its operation, and present preliminary experimental results validating the overall concept and the operation of the prototype device.

  16. Assessment value of 3-dimensional speckle tracking imaging for changes of early left ventricular longitudinal systolic function in patients with primary hypertension

    Directory of Open Access Journals (Sweden)

    Jing Yu

    2016-08-01

    Full Text Available Objective: To study the assessment value of 3-dimensional speckle tracking imaging for changes of early left ventricular longitudinal systolic function in patients with primary hypertension. Methods: Patients with primary hypertension who were treated in our hospital from May 2012 to October 2015 were selected, and 40 patients with left ventricular normal (LVN primary hypertension and 40 patients with left ventricular remodeling (LVR primary hypertension were screened according to Ganau typing and enrolled in the LVN group and LVR group of the study respectively; 40 cases of healthy volunteers who received physical examination in our hospital during the same period were selected as control group. Ultrasonic testing was conducted to determine conventional ultrasonic indicators and 3D-STI parameters, and serum was collected to determine AngII, ALD, TGF-β1 and Ang1-7 levels. Results: LVEDd, LVPWT and LVEF of LVN group were not significantly different from those of control group, LVEF of LVR group was not significantly different from those of LVN group and control group, and LVEDd and LVPWT of LVR group were significantly higher than those of LVN group and control group; absolute values of GLS, GCS, GRS and GAS as well as serum Ang1-7 level of LVN group was significantly lower than those of control group, serum AngII, ALD and TGF-β1 levels were higher than those of control group, absolute values of GLS, GCS, GRS and GAS as well as serum Ang1-7 level of LVR group was significantly lower than those of LVN group and control group, and serum AngII, ALD and TGF-β1 levels were higher than those of LVN group and control group; absolute values of GLS, GCS, GRS and GAS were negatively correlated with serum AngII, ALD and TGF-β1 levels, and positively correlated with serum Ang1-7 level. Conclusion: 3-dimensional speckle tracking imaging can be used for early evaluation of left ventricular longitudinal systolic function in patients with primary

  17. Speckle disturbance limit in laser-based cinema projection systems

    Science.gov (United States)

    Verschaffelt, Guy; Roelandt, Stijn; Meuret, Youri; van den Broeck, Wendy; Kilpi, Katriina; Lievens, Bram; Jacobs, An; Janssens, Peter; Thienpont, Hugo

    2015-09-01

    In a multi-disciplinary effort, we investigate the level of speckle that can be tolerated in a laser cinema projector based on a quality of experience experiment with movie clips shown to a test audience in a real-life movie theatre setting. We identify a speckle disturbance threshold by statistically analyzing the observers’ responses for different values of the amount of speckle, which was monitored using a well-defined speckle measurement method. The analysis shows that the speckle perception of a human observer is not only dependent on the objectively measured amount of speckle, but it is also strongly influenced by the image content. The speckle disturbance limit for movies turns out to be substantially larger than that for still images, and hence is easier to attain.

  18. Speckle dynamics under ergodicity breaking

    Science.gov (United States)

    Sdobnov, Anton; Bykov, Alexander; Molodij, Guillaume; Kalchenko, Vyacheslav; Jarvinen, Topias; Popov, Alexey; Kordas, Krisztian; Meglinski, Igor

    2018-04-01

    Laser speckle contrast imaging (LSCI) is a well-known and versatile approach for the non-invasive visualization of flows and microcirculation localized in turbid scattering media, including biological tissues. In most conventional implementations of LSCI the ergodic regime is typically assumed valid. However, most composite turbid scattering media, especially biological tissues, are non-ergodic, containing a mixture of dynamic and static centers of light scattering. In the current study, we examined the speckle contrast in different dynamic conditions with the aim of assessing limitations in the quantitative interpretation of speckle contrast images. Based on a simple phenomenological approach, we introduced a coefficient of speckle dynamics to quantitatively assess the ratio of the dynamic part of a scattering medium to the static one. The introduced coefficient allows one to distinguish real changes in motion from the mere appearance of static components in the field of view. As examples of systems with static/dynamic transitions, thawing and heating of Intralipid samples were studied by the LSCI approach.

  19. How Does Subclinical Hyperthyroidism Affect Right Heart Function and Mechanics?

    Science.gov (United States)

    Tadic, Marijana; Celic, Vera; Cuspidi, Cesare; Ilic, Sanja; Zivanovic, Vladimir; Marjanovic, Tamara

    2016-02-01

    Right heart function and mechanics have not been investigated in patients with subclinical hyperthyroidism. Our aim was to investigate right ventricular (RV) and right atrial (RA) function and deformation as evaluated by 3-dimensional echocardiography (3DE) and speckle-tracking 2-dimensional echocardiography (2DE) in these individuals. We included 39 untreated women with endogenous subclinical hyperthyroidism and 39 healthy women matched by age. All participants underwent laboratory analyses that included thyroid hormone levels and comprehensive 2DE and 3DE examinations. Three-dimensional echocardiographic RV volumes were significantly elevated in the patients with subclinical hyperthyroidism (P < .05), whereas the 3DE RV ejection fraction was reduced in this group, but with borderline significance. Two-dimensional echocardiographic longitudinal RV and RA strain were significantly reduced in the patients with subclinical hyperthyroidism. Two-dimensional echocardiographic RV systolic and early diastolic strain rates were reduced, whereas late diastolic strain rates were increased in the patients with subclinical hyperthyroidism. The same changes were detected in RA mechanics among the patients with subclinical hyperthyroidism. The thyrotropin (TSH) level correlated with the left ventricular mass index, transmitral early diastolic peak flow velocity (E)/late diastolic flow velocity (A) ratio, tricuspid E/A ratio, 2DE RV global strain, 2DE RA, strain, and 3DE RV end-diastolic volume. A multivariate regression analysis showed that the mitral E/A ratio, 2DE RV global strain, and 3DE RV end-diastolic volume were independently associated with the TSH level. Right ventricular and RA function as evaluated by 3DE and speckle-tracking 2DE is significantly impaired in patients with subclinical hyperthyroidism. The TSH level correlated with parameters for RV function and mechanics in the whole study population. © 2016 by the American Institute of Ultrasound in Medicine.

  20. Two-dimensional speckle tracking echocardiography prognostic parameters in patients after acute myocardial infarction.

    Science.gov (United States)

    Haberka, Maciej; Liszka, Jerzy; Kozyra, Andrzej; Finik, Maciej; Gąsior, Zbigniew

    2015-03-01

    The aim of the study was to evaluate the left ventricle (LV) function with speckle tracking echocardiography (STE) and to assess its relation to prognosis in patients after acute myocardial infarction (AMI). Sixty-three patients (F/M = 16/47 pts; 62.33 ± 11.85 years old) with AMI (NSTEMI/STEMI 24/39 pts) and successful percutaneous coronary intervention (PCI) with stent implantation (thrombolysis in myocardial infarction; TIMI 3 flow) were enrolled in this study. All patients underwent baseline two-dimensional conventional echocardiography and STE 3 days (baseline) and 30 days after PCI. All patients were followed up for cardiovascular clinical endpoints, major adverse cardiovascular endpoint (MACE), and functional status (Canadian Cardiovascular Society and New York Heart Association). During the follow-up (31.9 ± 5.1 months), there were 3 cardiovascular deaths, 15 patients had AMI, 2 patients had cerebral infarction, 24 patients reached the MACE. Baseline LV torsion (P = 0.035), but none of the other strain parameters were associated with the time to first unplanned cardiovascular hospitalization. Univariate analysis showed that baseline longitudinal two-chamber and four-chamber strain (sLa2 0 and sLa4 0) and the same parameters obtained 30 days after the AMI together with transverse four-chamber strain (sLa2 30, sLa4 30, and sTa4 30) were significantly associated with combined endpoint (MACE). The strongest association in the univariate analysis was found for the baseline sLa2. However, in multivariable analysis only a left ventricular remodeling (LVR - 27% pts) was significantly associated with MACE and strain parameters were not associated with the combined endpoint. The assessment of LV function with STE may improve cardiovascular risk prediction in postmyocardial infarction patients. © 2014, Wiley Periodicals, Inc.

  1. Speckle-learning-based object recognition through scattering media.

    Science.gov (United States)

    Ando, Takamasa; Horisaki, Ryoichi; Tanida, Jun

    2015-12-28

    We experimentally demonstrated object recognition through scattering media based on direct machine learning of a number of speckle intensity images. In the experiments, speckle intensity images of amplitude or phase objects on a spatial light modulator between scattering plates were captured by a camera. We used the support vector machine for binary classification of the captured speckle intensity images of face and non-face data. The experimental results showed that speckles are sufficient for machine learning.

  2. Finding small displacements of recorded speckle patterns: revisited

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Jakobsen, Michael Linde; Chakrabarti, Maumita

    2015-01-01

    An analytical expression for the bias effect in digital speckle correlation is derived based on a Gaussian approximation of the spatial pixel size and array extent. The evaluation is carried out having assumed an incident speckle field. The analysis is focused on speckle displacements in the order...

  3. Direct comparison of cardiac magnetic resonance feature tracking and 2D/3D echocardiography speckle tracking for evaluation of global left ventricular strain.

    Science.gov (United States)

    Obokata, Masaru; Nagata, Yasufumi; Wu, Victor Chien-Chia; Kado, Yuichiro; Kurabayashi, Masahiko; Otsuji, Yutaka; Takeuchi, Masaaki

    2016-05-01

    Cardiac magnetic resonance (CMR) feature tracking (FT) with steady-state free precession (SSFP) has advantages over traditional myocardial tagging to analyse left ventricular (LV) strain. However, direct comparisons of CMRFT and 2D/3D echocardiography speckle tracking (2/3DEST) for measurement of LV strain are limited. The aim of this study was to investigate the feasibility and reliability of CMRFT and 2D/3DEST for measurement of global LV strain. We enrolled 106 patients who agreed to undergo both CMR and 2D/3DE on the same day. SSFP images at multiple short-axis and three apical views were acquired. 2DE images from three levels of short-axis, three apical views, and 3D full-volume datasets were also acquired. Strain data were expressed as absolute values. Feasibility was highest in CMRFT, followed by 2DEST and 3DEST. Analysis time was shortest in 3DEST, followed by CMRFT and 2DEST. There was good global longitudinal strain (GLS) correlation between CMRFT and 2D/3DEST (r = 0.83 and 0.87, respectively) with the limit of agreement (LOA) ranged from ±3.6 to ±4.9%. Excellent global circumferential strain (GCS) correlation between CMRFT and 2D/3DEST was observed (r = 0.90 and 0.88) with LOA of ±6.8-8.5%. Global radial strain showed fair correlations (r = 0.69 and 0.82, respectively) with LOA ranged from ±12.4 to ±16.3%. CMRFT GCS showed least observer variability with highest intra-class correlation. Although not interchangeable, the high GLS and GCS correlation between CMRFT and 2D/3DEST makes CMRFT a useful modality for quantification of global LV strain in patients, especially those with suboptimal echo image quality. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  4. Speckle imaging algorithms for planetary imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    I will discuss the speckle imaging algorithms used to process images of the impact sites of the collision of comet Shoemaker-Levy 9 with Jupiter. The algorithms use a phase retrieval process based on the average bispectrum of the speckle image data. High resolution images are produced by estimating the Fourier magnitude and Fourier phase of the image separately, then combining them and inverse transforming to achieve the final result. I will show raw speckle image data and high-resolution image reconstructions from our recent experiment at Lick Observatory.

  5. Improvement of continuous subcutaneous insulin infusion on patients with type 2 diabetes mellitus by 3-dimensional speckle tracking echocardiography.

    Science.gov (United States)

    Luo, Hong-Xia; Zhou, Xiao-Ling; Kou, Hong-Ju; Ni, Xian-Wei; Wu, Qing; Zou, Chun-Peng; Wu, Dao-Zhu; Liu, Yong-Fang

    2018-03-01

    Three-dimensional speckle tracking echocardiography (3D-STE) was used to evaluate the improvement of continuous subcutaneous insulin infusion on the left ventricular (LV) systolic function of patients with type 2 diabetes mellitu (T2DM). We recruited T2DM patients (38 cases, diabetic group) and healthy volunteers (35 cases, control group) to collect LV full volume imaging. TomTec software was used for calculating LV global longitudinal strain (LVGLS), global circumferential strain (LVGCS), peak twist (LVTW), peak apical rotation (LVPAR), ejection fraction (LVEF), and torsion (LVT). All indices were re-tested 2 weeks later after intensive treatment of insulin pump. LVGLS, LVGCS, LVTW and LVPAR in diabetic group were significantly decreased than control group. LVGLS and LVGCS in pre-treatment diabetic group were significantly increased than post-treatment. LVGLS, LVGCS, LVTW and LVPAR had correlations among control, pre-treatment and post-treatment diabetic groups. There were no significant differences in LVEDV, LVESV, LVEF, LVT and R-R. LV systolic function of patients with T2DM complicated with microangiopathy was improved after treatment of continuous subcutaneous insulin infusion. In addition, therapeutic effect could be accurately evaluated by 3D-STE which had vital clinical application.

  6. Assessment of left ventricular regional function in affected and carrier dogs with duchenne muscular dystrophy using speckle tracking echocardiography

    Directory of Open Access Journals (Sweden)

    Yugeta Naoko

    2011-05-01

    Full Text Available Abstract Background Two-dimensional speckle tracking echocardiography (STE is a relatively new method to detect regional myocardial dysfunction. To assess left ventricular (LV regional myocardial dysfunction using STE in Duchenne muscular dystrophy model dogs (CXMDJ without overt clinical signs of heart failure. Methods Six affected dogs, 8 carrier dogs with CXMDJ, and 8 control dogs were used. Conventional echocardiography, systolic and diastolic function by Doppler echocardiography, tissue Doppler imaging (TDI, and strain indices using STE, were assessed and compared among the 3 groups. Results Significant differences were seen in body weight, transmitral E wave and E' wave derived from TDI among the 3 groups. Although no significant difference was observed in any global strain indices, in segmental analysis, the peak radial strain rate during early diastole in posterior segment at chordae the tendineae level showed significant differences among the 3 groups. Conclusions The myocardial strain rate by STE served to detect the impaired cardiac diastolic function in CXMDJ without any obvious LV dilation or clinical signs. The radial strain rate may be a useful parameter to detect early myocardial impairment in CXMDJ.

  7. Two-dimensional speckle tracking echocardiography demonstrates no effect of active acromegaly on left ventricular strain.

    Science.gov (United States)

    Volschan, I C M; Kasuki, L; Silva, C M S; Alcantara, M L; Saraiva, R M; Xavier, S S; Gadelha, M R

    2017-06-01

    Speckle tracking echocardiography (STE) allows for the study of myocardial strain (ε), a marker of early and subclinical ventricular systolic dysfunction. Cardiac disease may be present in patients with acromegaly; however, STE has never been used to evaluate these patients. To evaluate left ventricular (LV) global longitudinal strain in patients with active acromegaly with normal LV systolic function. Cross-sectional clinical study. Patients with active acromegaly with no detectable heart disease and a control group were matched for age, gender, arterial hypertension and diabetes mellitus underwent STE. Global LV longitudinal ε (GLS), left ventricular mass index (LVMi), left ventricular ejection fraction (LVEF) and relative wall thickness (RWT) were obtained via two-dimensional (2D) echocardiography using STE. Thirty-seven patients with active acromegaly (mean age 45.6 ± 13.8; 48.6% were males) and 48 controls were included. The mean GLS was not significantly different between the acromegaly group and the control group (in %, -20.1 ± 3.1 vs. -19.4 ± 2.2, p = 0.256). Mean LVMi was increased in the acromegaly group (in g/m 2 , 101.6 ± 27.1 vs. 73.2 ± 18.6, p Acromegaly patients, despite presenting with a higher LVMi when analyzed by 2D echocardiography, did not present with impairment in the strain when compared to a control group; this finding indicates a low chance of evolution to systolic dysfunction and agrees with recent studies that show a lower frequency of cardiac disease in these patients.

  8. Echocardiographic agreement in the diagnostic evaluation for infective endocarditis

    DEFF Research Database (Denmark)

    Lauridsen, Trine Kiilerich; Selton-Suty, Christine; Tong, Steven Y C

    2016-01-01

    Echocardiography is essential for the diagnosis and management of infective endocarditis (IE). However, the reproducibility for the echocardiographic assessment of variables relevant to IE is unknown. Objectives of this study were: (1) To define the reproducibility for IE echocardiographic...... variables and (2) to describe a methodology for assessing quality in an observational cohort containing site-interpreted data. IE reproducibility was assessed on a subset of echocardiograms from subjects enrolled in the International Collaboration on Endocarditis registry. Specific echocardiographic case...

  9. Twisted speckle entities inside wave-front reversal mirrors

    International Nuclear Information System (INIS)

    Okulov, A. Yu

    2009-01-01

    The previously unknown property of the optical speckle pattern reported. The interference of a speckle with the counterpropagating phase-conjugated (PC) speckle wave produces a randomly distributed ensemble of a twisted entities (ropes) surrounding optical vortex lines. These entities appear in a wide range of a randomly chosen speckle parameters inside the phase-conjugating mirrors regardless to an internal physical mechanism of the wave-front reversal. These numerically generated interference patterns are relevant to the Brillouin PC mirrors and to a four-wave mixing PC mirrors based upon laser trapped ultracold atomic cloud.

  10. Multiple speckle illumination for optical-resolution photoacoustic imaging

    Science.gov (United States)

    Poisson, Florian; Stasio, Nicolino; Moser, Christophe; Psaltis, Demetri; Bossy, Emmanuel

    2017-03-01

    Optical-resolution photoacoustic microscopy offers exquisite and specific contrast to optical absorption. Conventional approaches generally involves raster scanning a focused spot over the sample. Here, we demonstrate that a full-field illumination approach with multiple speckle illumination can also provide diffraction-limited optical-resolution photoacoustic images. Two different proof-of-concepts are demonstrated with micro-structured test samples. The first approach follows the principle of correlation/ghost imaging,1, 2 and is based on cross-correlating photoacoustic signals under multiple speckle illumination with known speckle patterns measured during a calibration step. The second approach is a speckle scanning microscopy technique, which adapts the technique proposed in fluorescence microscopy by Bertolotti and al.:3 in our work, spatially unresolved photoacoustic measurements are performed for various translations of unknown speckle patterns. A phase-retrieval algorithm is used to reconstruct the object from the knowledge of the modulus of its Fourier Transform yielded by the measurements. Because speckle patterns naturally appear in many various situations, including propagation through biological tissue or multi-mode fibers (for which focusing light is either very demanding if not impossible), speckle-illumination-based photoacoustic microscopy provides a powerful framework for the development of novel reconstruction approaches, well-suited to compressed sensing approaches.2

  11. Statistics of spatially integrated speckle intensity difference

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Yura, Harold

    2009-01-01

    We consider the statistics of the spatially integrated speckle intensity difference obtained from two separated finite collecting apertures. For fully developed speckle, closed-form analytic solutions for both the probability density function and the cumulative distribution function are derived...... here for both arbitrary values of the mean number of speckles contained within an aperture and the degree of coherence of the optical field. Additionally, closed-form expressions are obtained for the corresponding nth statistical moments....

  12. ECHOCARDIOGRAPHIC DIAGNOSTICS OF CARCINOID HEART DISEASE

    Directory of Open Access Journals (Sweden)

    Janez Ravnik

    2002-09-01

    Full Text Available Background. Carcinoid heart disease is a rare heart disease which affects endocard and heart valves on the right side of heart. It affects only patients with manifested carcinoid syndrome, which is thought to be the consequence of secretory active metastases of carcinoid tumour. The carcinoid endocardial plaques cause structural changes of tricuspid and pulmonic valve and later on their stenosis and/or insufficiency.Patients and methods. In this article we introduce a carcinoid valve heart disease (CVHD scoring system for easier end exact echocardiographic diagnostics. Four echocardiographic parameters are beeing estimated: structural changes of tricuspid valve, tricuspid valve regurgitation, stenosis of pulmonic valve and pulmonic valve regurgitation.Conclusions. The scoring system allows us to make an early diagnosis and evaluation of progression of carcinoid heart disease, which is very important for planning the treatment process. Our experiences confirm the usefulness of this scoring system in echocardiographic follow–up of patients with carcinoid syndrome.

  13. Echocardiographic abnormalities in hypertensive patients

    International Nuclear Information System (INIS)

    Rodulfo Garcia, Maikel; Tornes Perez, Victor Manuel; Castellanos Tardo, Juan Ramon

    2012-01-01

    A descriptive cross-sectional study was carried out in 120 hypertensive patients with a course of 5 or more years, who went to the emergency room of 'Saturnino Lora' Provincial Teaching Hospital from November 2010 to November 2011 in order to determine the presence or absence of echocardiographic abnormalities typical of hypertension. Of these, 78,3 % was affected, most of whom reported not to continue with regular previous medical treatment, and 21,7 % had not these abnormalities. Age group of 50-60 years, males and blacks prevailed in the case material. The most significant echocardiographic findings were left ventricular hypertrophy and heart failure with ejection fraction of left ventricle preserved

  14. Identification of a chemical inhibitor for nuclear speckle formation: Implications for the function of nuclear speckles in regulation of alternative pre-mRNA splicing

    Energy Technology Data Exchange (ETDEWEB)

    Kurogi, Yutaro; Matsuo, Yota; Mihara, Yuki; Yagi, Hiroaki; Shigaki-Miyamoto, Kaya; Toyota, Syukichi; Azuma, Yuko [Department of Biological Sciences, Graduate School of Science and Technology, Kumamoto University, Chuo-ku, Kumamoto 860-8555 (Japan); Igarashi, Masayuki [Laboratory of Disease Biology, Institute of Microbial Chemistry, Shinagawa-ku, Tokyo 141-0021 (Japan); Tani, Tokio, E-mail: ttani@sci.kumamoto-u.ac.jp [Department of Biological Sciences, Graduate School of Science and Technology, Kumamoto University, Chuo-ku, Kumamoto 860-8555 (Japan)

    2014-03-28

    Highlights: • We identified tubercidin as a compound inducing aberrant formation of the speckles. • Tubercidin causes delocalization of poly (A){sup +}RNAs from nuclear speckles. • Tubercidin induces dispersion of splicing factors from nuclear speckles. • Tubercidin affects alternative pre-mRNA splicing. • Nuclear speckles play a role in regulation of alternative pre-mRNA splicing. - Abstract: Nuclear speckles are subnuclear structures enriched with RNA processing factors and poly (A){sup +} RNAs comprising mRNAs and poly (A){sup +} non-coding RNAs (ncRNAs). Nuclear speckles are thought to be involved in post-transcriptional regulation of gene expression, such as pre-mRNA splicing. By screening 3585 culture extracts of actinomycetes with in situ hybridization using an oligo dT probe, we identified tubercidin, an analogue of adenosine, as an inhibitor of speckle formation, which induces the delocalization of poly (A){sup +} RNA and dispersion of splicing factor SRSF1/SF2 from nuclear speckles in HeLa cells. Treatment with tubercidin also decreased steady-state MALAT1 long ncRNA, thought to be involved in the retention of SRSF1/SF2 in nuclear speckles. In addition, we found that tubercidin treatment promoted exon skipping in the alternative splicing of Clk1 pre-mRNA. These results suggest that nuclear speckles play a role in modulating the concentration of splicing factors in the nucleoplasm to regulate alternative pre-mRNA splicing.

  15. Lagrangian speckle model and tissue-motion estimation--theory.

    Science.gov (United States)

    Maurice, R L; Bertrand, M

    1999-07-01

    It is known that when a tissue is subjected to movements such as rotation, shearing, scaling, etc., changes in speckle patterns that result act as a noise source, often responsible for most of the displacement-estimate variance. From a modeling point of view, these changes can be thought of as resulting from two mechanisms: one is the motion of the speckles and the other, the alterations of their morphology. In this paper, we propose a new tissue-motion estimator to counteract these speckle decorrelation effects. The estimator is based on a Lagrangian description of the speckle motion. This description allows us to follow local characteristics of the speckle field as if they were a material property. This method leads to an analytical description of the decorrelation in a way which enables the derivation of an appropriate inverse filter for speckle restoration. The filter is appropriate for linear geometrical transformation of the scattering function (LT), i.e., a constant-strain region of interest (ROI). As the LT itself is a parameter of the filter, a tissue-motion estimator can be formulated as a nonlinear minimization problem, seeking the best match between the pre-tissue-motion image and a restored-speckle post-motion image. The method is tested, using simulated radio-frequency (RF) images of tissue undergoing axial shear.

  16. Highly porous nanoberyllium for X-ray beam speckle suppression

    Energy Technology Data Exchange (ETDEWEB)

    Goikhman, Alexander, E-mail: agoikhman@ymail.com; Lyatun, Ivan; Ershov, Petr [Immanuel Kant Baltic Federal University, Nevskogo str. 14, Kaliningrad 236041 (Russian Federation); Snigireva, Irina [European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France); Wojda, Pawel [Immanuel Kant Baltic Federal University, Nevskogo str. 14, Kaliningrad 236041 (Russian Federation); Gdańsk University of Technology, 11/12 G. Narutowicza, Gdańsk 80-233 (Poland); Gorlevsky, Vladimir; Semenov, Alexander; Sheverdyaev, Maksim; Koletskiy, Viktor [A. A. Bochvar High-Technology Scientific Research Institute for Inorganic Materials, Rogova str. 5a, Moscow 123098 (Russian Federation); Snigirev, Anatoly [Immanuel Kant Baltic Federal University, Nevskogo str. 14, Kaliningrad 236041 (Russian Federation); European Synchrotron Radiation Facility, BP 220, 38043 Grenoble (France)

    2015-04-09

    A speckle suppression device containing highly porous nanoberyllium is proposed for manipulating the spatial coherence length and removing undesirable speckle structure during imaging experiments. This paper reports a special device called a ‘speckle suppressor’, which contains a highly porous nanoberyllium plate squeezed between two beryllium windows. The insertion of the speckle suppressor in an X-ray beam allows manipulation of the spatial coherence length, thus changing the effective source size and removing the undesirable speckle structure in X-ray imaging experiments almost without beam attenuation. The absorption of the nanoberyllium plate is below 1% for 1 mm thickness at 12 keV. The speckle suppressor was tested on the ID06 ESRF beamline with X-rays in the energy range from 9 to 15 keV. It was applied for the transformation of the phase–amplitude contrast to the pure amplitude contrast in full-field microscopy.

  17. Highly porous nanoberyllium for X-ray beam speckle suppression

    International Nuclear Information System (INIS)

    Goikhman, Alexander; Lyatun, Ivan; Ershov, Petr; Snigireva, Irina; Wojda, Pawel; Gorlevsky, Vladimir; Semenov, Alexander; Sheverdyaev, Maksim; Koletskiy, Viktor; Snigirev, Anatoly

    2015-01-01

    A speckle suppression device containing highly porous nanoberyllium is proposed for manipulating the spatial coherence length and removing undesirable speckle structure during imaging experiments. This paper reports a special device called a ‘speckle suppressor’, which contains a highly porous nanoberyllium plate squeezed between two beryllium windows. The insertion of the speckle suppressor in an X-ray beam allows manipulation of the spatial coherence length, thus changing the effective source size and removing the undesirable speckle structure in X-ray imaging experiments almost without beam attenuation. The absorption of the nanoberyllium plate is below 1% for 1 mm thickness at 12 keV. The speckle suppressor was tested on the ID06 ESRF beamline with X-rays in the energy range from 9 to 15 keV. It was applied for the transformation of the phase–amplitude contrast to the pure amplitude contrast in full-field microscopy

  18. Mitral valve repair: an echocardiographic review: Part 2.

    Science.gov (United States)

    Maslow, Andrew

    2015-04-01

    Echocardiographic imaging of the mitral valve before and immediately after repair is crucial to the immediate and long-term outcome. Prior to mitral valve repair, echocardiographic imaging helps determine the feasibility and method of repair. After the repair, echocardiographic imaging displays the new baseline anatomy, assesses function, and determines whether or not further management is necessary. Three-dimensional imaging has improved the assessment of the mitral valve and facilitates communication with the surgeon by providing the surgeon with an image that he/she might see upon opening up the atrium. Further advancements in imaging will continue to improve the understanding of the function and dysfunction of the mitral valve both before and after repair. This information will improve treatment options, timing of invasive therapies, and advancements of repair techniques to yield better short- and long-term patient outcomes. The purpose of this review was to connect the echocardiographic evaluation with the surgical procedure. Bridging the pre- and post-CPB imaging with the surgical procedure allows a greater understanding of mitral valve repair.

  19. A SIMPLE HETERODYNE TEMPORAL SPECKLE-PATTERN INTERFEROMETER

    International Nuclear Information System (INIS)

    Wong, W. O.; Gao, Z.; Lu, J.

    2010-01-01

    A common light path design of heterodyne speckle pattern interferometer based on temporal speckle pattern interferometry is proposed for non-contact, full-field and real-time continuous displacement measurement. Double frequency laser is produced by rotating a half wave plate. An experiment was carried out to measure the dynamic displacement of a cantilever plate for testing the proposed common path heterodyne speckle pattern interferometer. The accuracy of displacement measurement was checked by measuring the motion at the mid-point of the plate with a point displacement sensor.

  20. Correlation of Spatially Filtered Dynamic Speckles in Distance Measurement Application

    International Nuclear Information System (INIS)

    Semenov, Dmitry V.; Nippolainen, Ervin; Kamshilin, Alexei A.; Miridonov, Serguei V.

    2008-01-01

    In this paper statistical properties of spatially filtered dynamic speckles are considered. This phenomenon was not sufficiently studied yet while spatial filtering is an important instrument for speckles velocity measurements. In case of spatial filtering speckle velocity information is derived from the modulation frequency of filtered light power which is measured by photodetector. Typical photodetector output is represented by a narrow-band random noise signal which includes non-informative intervals. Therefore more or less precious frequency measurement requires averaging. In its turn averaging implies uncorrelated samples. However, conducting research we found that correlation is typical property not only of dynamic speckle patterns but also of spatially filtered speckles. Using spatial filtering the correlation is observed as a response of measurements provided to the same part of the object surface or in case of simultaneously using several adjacent photodetectors. Found correlations can not be explained using just properties of unfiltered dynamic speckles. As we demonstrate the subject of this paper is important not only from pure theoretical point but also from the point of applied speckle metrology. E.g. using single spatial filter and an array of photodetector can greatly improve accuracy of speckle velocity measurements

  1. Advances in speckle metrology and related techniques

    CERN Document Server

    Kaufmann, Guillermo H

    2010-01-01

    Speckle metrology includes various optical techniques that are based on the speckle fields generated by reflection from a rough surface or by transmission through a rough diffuser. These techniques have proven to be very useful in testing different materials in a non-destructive way. They have changed dramatically during the last years due to the development of modern optical components, with faster and more powerful digital computers, and novel data processing approaches. This most up-to-date overview of the topic describes new techniques developed in the field of speckle metrology over the l

  2. Speckle imaging of globular clusters

    International Nuclear Information System (INIS)

    Sams, B.J. III

    1990-01-01

    Speckle imaging is a powerful tool for high resolution astronomy. Its application to the core regions of globular clusters produces high resolution stellar maps of the bright stars, but is unable to image the faint stars which are most reliable dynamical indicators. The limits on resolving these faint, extended objects are physical, not algorithmic, and cannot be overcome using speckle. High resolution maps may be useful for resolving multicomponent stellar systems in the cluster centers. 30 refs

  3. Echocardiographic evaluation of thalassemia intermedia patients in Duhok, Iraq.

    Science.gov (United States)

    Mohammad, Ameen Mosa

    2014-12-11

    Cardiac complications are among the most serious problems of thalassemia intermedia patients. The current study was initiated to address the latter issue through the study of the echocardiographic findings and correlate it with clinical characteristics of thalassemia intermedia patients in Duhok, Kurdistan region, Iraq. An echocardiographic assessment of 61 beta-thalassemia intermedia cases was performed. It included 30 males and 31 females, with a mean age 19.6 ± 7.5 years. The standard echostudy of two-dimension and M-mode measurements of cardiac chambers were done. The continuous doppler regurgitant jet of tricuspid and pulmonary valves were recorded. Left ventricle diastolic function was assessed by pulsed doppler of mitral valve inflow. To correlate the clinical with echocardiographic findings, patients were divided, according to tricuspid regurgitant velocity, into three groups (intermedia patients. Therapeutic trails targeting these complications are indicated, and echocardiographic assessment is necessary to be offered early for thalassemia intermedia.

  4. Understanding the exposure-time effect on speckle contrast measurements for laser displays

    Science.gov (United States)

    Suzuki, Koji; Kubota, Shigeo

    2018-02-01

    To evaluate the influence of exposure time on speckle noise for laser displays, speckle contrast measurement method was developed observable at a human eye response time using a high-sensitivity camera which has a signal multiplying function. The nonlinearity of camera light sensitivity was calibrated to measure accurate speckle contrasts, and the measuring lower limit noise of speckle contrast was improved by applying spatial-frequency low pass filter to the captured images. Three commercially available laser displays were measured over a wide range of exposure times from tens of milliseconds to several seconds without adjusting the brightness of laser displays. The speckle contrast of raster-scanned mobile projector without any speckle-reduction device was nearly constant over various exposure times. On the contrary to this, in full-frame projection type laser displays equipped with a temporally-averaging speckle-reduction device, some of their speckle contrasts close to the lower limits noise were slightly increased at the shorter exposure time due to the noise. As a result, the exposure-time effect of speckle contrast could not be observed in our measurements, although it is more reasonable to think that the speckle contrasts of laser displays, which are equipped with the temporally-averaging speckle-reduction device, are dependent on the exposure time. This discrepancy may be attributed to the underestimation of temporal averaging factor. We expected that this method is useful for evaluating various laser displays and clarify the relationship between the speckle noise and the exposure time for a further verification of speckle reduction.

  5. An adaptive Kalman filter for speckle reductions in ultrasound images

    International Nuclear Information System (INIS)

    Castellini, G.; Labate, D.; Masotti, L.; Mannini, E.; Rocchi, S.

    1988-01-01

    Speckle is the term used to describe the granular appearance found in ultrasound images. The presence of speckle reduces the diagnostic potential of the echographic technique because it tends to mask small inhomogeneities of the investigated tissue. We developed a new method of speckle reductions that utilizes an adaptive one-dimensional Kalman filter based on the assumption that the observed image can be considered as a superimposition of speckle on a ''true images''. The filter adaptivity, necessary to avoid loss of resolution, has been obtained by statistical considerations on the local signal variations. The results of the applications of this particular Kalman filter, both on A-Mode and B-MODE images, show a significant speckle reduction

  6. Ectoparasites and intestinal helminths of speckled pigeon ...

    African Journals Online (AJOL)

    Ectoparasites and intestinal helminths of speckled pigeon ( Columba guinea Hartlaub and Finsch 1870) in Zaria, Nigeria. ... Science World Journal ... A total of 30 (20 males and 10 females) Speckled Pigeons trapped from the wild in Zaria and its environs, Nigeria, were examined for ectoparasites and intestinal helminths, ...

  7. Statistical characterization of speckle noise in coherent imaging systems

    Science.gov (United States)

    Yaroslavsky, Leonid; Shefler, A.

    2003-05-01

    Speckle noise imposes fundamental limitation on image quality in coherent radiation based imaging and optical metrology systems. Speckle noise phenomena are associated with properties of objects to diffusely scatter irradiation and with the fact that in recording the wave field, a number of signal distortions inevitably occur due to technical limitations inherent to hologram sensors. The statistical theory of speckle noise was developed with regard to only limited resolving power of coherent imaging devices. It is valid only asymptotically as much as the central limit theorem of the probability theory can be applied. In applications this assumption is not always applicable. Moreover, in treating speckle noise problem one should also consider other sources of the hologram deterioration. In the paper, statistical properties of speckle due to the limitation of hologram size, dynamic range and hologram signal quantization are studied by Monte-Carlo simulation for holograms recorded in near and far diffraction zones. The simulation experiments have shown that, for limited resolving power of the imaging system, widely accepted opinion that speckle contrast is equal to one holds only for rather severe level of the hologram size limitation. For moderate limitations, speckle contrast changes gradually from zero for no limitation to one for limitation to less than about 20% of hologram size. The results obtained for the limitation of the hologram sensor"s dynamic range and hologram signal quantization reveal that speckle noise due to these hologram signal distortions is not multiplicative and is directly associated with the severity of the limitation and quantization. On the base of the simulation results, analytical models are suggested.

  8. Laser speckle imaging based on photothermally driven convection

    Science.gov (United States)

    Regan, Caitlin; Choi, Bernard

    2016-02-01

    Laser speckle imaging (LSI) is an interferometric technique that provides information about the relative speed of moving scatterers in a sample. Photothermal LSI overcomes limitations in depth resolution faced by conventional LSI by incorporating an excitation pulse to target absorption by hemoglobin within the vascular network. Here we present results from experiments designed to determine the mechanism by which photothermal LSI decreases speckle contrast. We measured the impact of mechanical properties on speckle contrast, as well as the spatiotemporal temperature dynamics and bulk convective motion occurring during photothermal LSI. Our collective data strongly support the hypothesis that photothermal LSI achieves a transient reduction in speckle contrast due to bulk motion associated with thermally driven convection. The ability of photothermal LSI to image structures below a scattering medium may have important preclinical and clinical applications.

  9. Speckle reduction in digital holography with resampling ring masks

    Science.gov (United States)

    Zhang, Wenhui; Cao, Liangcai; Jin, Guofan

    2018-01-01

    One-shot digital holographic imaging has the advantages of high stability and low temporal cost. However, the reconstruction is affected by the speckle noise. Resampling ring-mask method in spectrum domain is proposed for speckle reduction. The useful spectrum of one hologram is divided into several sub-spectra by ring masks. In the reconstruction, angular spectrum transform is applied to guarantee the calculation accuracy which has no approximation. N reconstructed amplitude images are calculated from the corresponding sub-spectra. Thanks to speckle's random distribution, superimposing these N uncorrelated amplitude images would lead to a final reconstructed image with lower speckle noise. Normalized relative standard deviation values of the reconstructed image are used to evaluate the reduction of speckle. Effect of the method on the spatial resolution of the reconstructed image is also quantitatively evaluated. Experimental and simulation results prove the feasibility and effectiveness of the proposed method.

  10. Speckle-modulating optical coherence tomography in living mice and humans

    Science.gov (United States)

    Liba, Orly; Lew, Matthew D.; Sorelle, Elliott D.; Dutta, Rebecca; Sen, Debasish; Moshfeghi, Darius M.; Chu, Steven; de La Zerda, Adam

    2017-06-01

    Optical coherence tomography (OCT) is a powerful biomedical imaging technology that relies on the coherent detection of backscattered light to image tissue morphology in vivo. As a consequence, OCT is susceptible to coherent noise (speckle noise), which imposes significant limitations on its diagnostic capabilities. Here we show speckle-modulating OCT (SM-OCT), a method based purely on light manipulation that virtually eliminates speckle noise originating from a sample. SM-OCT accomplishes this by creating and averaging an unlimited number of scans with uncorrelated speckle patterns without compromising spatial resolution. Using SM-OCT, we reveal small structures in the tissues of living animals, such as the inner stromal structure of a live mouse cornea, the fine structures inside the mouse pinna, and sweat ducts and Meissner's corpuscle in the human fingertip skin--features that are otherwise obscured by speckle noise when using conventional OCT or OCT with current state of the art speckle reduction methods.

  11. Echocardiographic versus histologic findings in Marfan syndrome.

    Science.gov (United States)

    Gu, Xiaoyan; He, Yihua; Li, Zhian; Han, Jiancheng; Chen, Jian; Nixon, J V Ian

    2015-02-01

    This retrospective study attempted to establish the prevalence of multiple-valve involvement in Marfan syndrome and to compare echocardiographic with histopathologic findings in Marfan patients undergoing valvular or aortic surgery. We reviewed echocardiograms of 73 Marfan patients who underwent cardiovascular surgery from January 2004 through October 2009. Tissue histology was available for comparison in 29 patients. Among the 73 patients, 66 underwent aortic valve replacement or the Bentall procedure. Histologic findings were available in 29 patients, all of whom had myxomatous degeneration. Of 63 patients with moderate or severe aortic regurgitation as determined by echocardiography, 4 had thickened aortic valves. The echocardiographic findings in 18 patients with mitral involvement included mitral prolapse in 15. Of 11 patients with moderate or severe mitral regurgitation as determined by echocardiography, 4 underwent mitral valve repair and 7 mitral valve replacement. Histologic findings among mitral valve replacement patients showed thickened valve tissue and myxomatous degeneration. Tricuspid involvement was seen echocardiographically in 8 patients, all of whom had tricuspid prolapse. Two patients had severe tricuspid regurgitation, and both underwent repair. Both mitral and tricuspid involvement were seen echocardiographically in 7 patients. Among the 73 patients undergoing cardiac surgery for Marfan syndrome, 66 had moderate or severe aortic regurgitation, although their valves manifested few histologic changes. Eighteen patients had mitral involvement (moderate or severe mitral regurgitation, prolapse, or both), and 8 had tricuspid involvement. Mitral valves were most frequently found to have histologic changes, but the tricuspid valve was invariably involved.

  12. Laser-induced speckle scatter patterns in Bacillus colonies

    Directory of Open Access Journals (Sweden)

    Huisung eKim

    2014-10-01

    Full Text Available Label-free bacterial colony phenotyping technology called BARDOT (BActerial Rapid Detection using Optical scattering Technology provided successful classification of several different bacteria at the genus, species, and serovar level. Recent experiments with colonies of Bacillus species provided strikingly different characteristics of elastic light scatter (ELS patterns, which were comprised of random speckles compared to other bacteria, which are dominated by concentric rings and spokes. Since this laser-based optical sensor interrogates the whole volume of the colony, 3-D information of micro- and macro-structures are all encoded in the far-field scatter patterns. Here, we present a theoretical model explaining the underlying mechanism of the speckle formation by the colonies from Bacillus species. Except for Bacillus polymyxa, all Bacillus spp. produced random bright spots on the imaging plane, which presumably dependent on the cellular and molecular organization and content within the colony. Our scatter model-based analysis revealed that colony spread resulting in variable surface roughness can modify the wavefront of the scatter field. As the center diameter of the Bacillus spp. colony grew from 500 μm to 900 μm, average speckles area decreased 2-fold and the number of small speckles increased 7-fold. In conclusion, as Bacillus colony grows, the average speckle size in the scatter pattern decreases and the number of smaller speckle increases due to the swarming growth characteristics of bacteria within the colony.

  13. Speckle reduction methods in laser-based picture projectors

    Science.gov (United States)

    Akram, M. Nadeem; Chen, Xuyuan

    2016-02-01

    Laser sources have been promised for many years to be better light sources as compared to traditional lamps or light-emitting diodes (LEDs) for projectors, which enable projectors having wide colour gamut for vivid image, super brightness and high contrast for the best picture quality, long lifetime for maintain free operation, mercury free, and low power consumption for green environment. A major technology obstacle in using lasers for projection has been the speckle noise caused by to the coherent nature of the lasers. For speckle reduction, current state of the art solutions apply moving parts with large physical space demand. Solutions beyond the state of the art need to be developed such as integrated optical components, hybrid MOEMS devices, and active phase modulators for compact speckle reduction. In this article, major methods reported in the literature for the speckle reduction in laser projectors are presented and explained. With the advancement in semiconductor lasers with largely reduced cost for the red, green and the blue primary colours, and the developed methods for their speckle reduction, it is hoped that the lasers will be widely utilized in different projector applications in the near future.

  14. Noninvasive Localization of Accessory Pathways in Wolff-Parkinson-White Syndrome by Three-Dimensional Speckle Tracking Echocardiography.

    Science.gov (United States)

    Ishizu, Tomoko; Seo, Yoshihiro; Igarashi, Miyako; Sekiguchi, Yukio; Machino-Ohtsuka, Tomoko; Ogawa, Kojiro; Kuroki, Kenji; Yamamoto, Masahiro; Nogami, Akihiko; Kawakami, Yasushi; Aonuma, Kazutaka

    2016-06-01

    We have developed a noninvasive isochrone activation imaging (AI) system with 3-dimensional (3D) speckle tracking echocardiography (STE), which allows visualization of the wavefront image of mechanical propagation of the accessory pathway (ACP) in Wolff-Parkinson-White syndrome. Patients with manifest Wolff-Parkinson-White syndrome were imaged in 3D-STE AI mode, which quantified the time from QRS onset to regional endocardial deformation. In 2 patients with left- and right-side ACP, we confirmed that intraoperative contact endocardial electric mapping and the 3D-STE AI system showed comparable images pre- and postablation. In normal heart assessment by 3D-echo AI, the earliest activation sites were found at the attachment of the papillary muscles in the left ventricle and midseptum in the right ventricle, and none showed earliest activation at the peri-atrioventricular valve annuli. An analyzer who was unaware of the clinical information assessed 39 ACP locations in 38 Wolff-Parkinson-White syndrome patients using 3D-STE. All showed abnormal perimitral or tricuspid annular activations, and the location of 34 ACP (87%) showed agreement with the successful ablation sites within a 2-o'clock range. Especially for left free wall ACP, 17/18 (94%) showed consistency with the ablation site within a 2 o'clock range. Among 15 ACP at the ventricular septum, 9 (60%) showed early local activation in both right and left sides of the septum. Isochrone AI with 3D-STE may be a promising noninvasive imaging tool to assess cardiac synchronized activation in normal hearts and detect abnormal breakthrough of mechanical activation from both atrioventricular annuli in Wolff-Parkinson-White syndrome. © 2016 American Heart Association, Inc.

  15. Measurement of eye aberrations in a speckle field

    International Nuclear Information System (INIS)

    Larichev, A V; Ivanov, P V; Iroshnikov, N G; Shmalgauzen, V I

    2001-01-01

    The influence of speckles on the performance of a Shark-Hartmann wavefront sensor is investigated in the eye aberration studies. The dependence of the phase distortion measurement error on the characteristic speckle size is determined experimentally. Scanning of the reference source was used to suppress the speckle structure of the laser beam scattered by the retina. The technique developed by us made it possible to study the time dependence of the human eye aberrations with a resolution of 30 ms. (laser applications and other topics in quantum electronics)

  16. Phase-processing as a tool for speckle reduction in pulse-echo images

    DEFF Research Database (Denmark)

    Healey, AJ; Leeman, S; Forsberg, F

    1991-01-01

    . Traditional speckle reduction procedures regard speckle correction as a stochastic process and trade image smoothing (resolution loss) for speckle reduction. Recently, a new phase acknowledging technique has been proposed that is unique in its ability to correct for speckle interference with no image......Due to the coherent nature of conventional ultrasound medical imaging systems interference artefacts occur in pulse echo images. These artefacts are generically termed 'speckle'. The phenomenon may severely limit low contrast resolution with clinically relevant information being obscured...

  17. Statistical Image Recovery From Laser Speckle Patterns With Polarization Diversity

    Science.gov (United States)

    2010-09-01

    several techniques for speckle suppression in optical imaging [19]. However, averaging nonimaged laser speckle patterns does not yield the same result...Comparison”. Applied Optics , 21(15):2758–2769, August 1982. 13. Fienup, James R. “Image Formation from Nonimaged Laser Speckle Patterns”. S. R. Robinson...6 ν Optical Frequency . . . . . . . . . . . . . . . . . . . . . . 6 t Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 ϕ

  18. Dynamical properties of speckled speckles

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Iversen, Theis Faber Quist; Hansen, Rene Skov

    2010-01-01

    the static diffuser and the plane of observation consist of an optical system that can be characterized by a complex-valued ABCD-matrix (e.g. simple and complex imaging systems, free space propagation in both the near-and far-field, and Fourier transform systems). The use of the complex ABCD-method means...... to be Gaussian but the derived expressions are not restricted to a plane incident beam. The results are applicable for speckle-based systems for determining mechanical displacements, especially for long-range systems, and for analyzing systems for measuring biological activity beyond a diffuse layer, e.g. blood...

  19. Influence of Positive End-Expiratory Pressure on Myocardial Strain Assessed by Speckle Tracking Echocardiography in Mechanically Ventilated Patients

    Directory of Open Access Journals (Sweden)

    Federico Franchi

    2013-01-01

    Full Text Available Purpose. The effects of mechanical ventilation (MV on speckle tracking echocardiography- (STE-derived variables are not elucidated. The aim of the study was to evaluate the effects of positive end-expiratory pressure (PEEP ventilation on 4-chamber longitudinal strain (LS analysis by STE. Methods. We studied 20 patients admitted to a mixed intensive care unit who required intubation for MV and PEEP titration due to hypoxia. STE was performed at three times: (T1 PEEP = 5 cmH2O; (T2 PEEP = 10 cmH2O; and (T3 PEEP = 15 cmH2O. STE analysis was performed offline using a dedicated software (XStrain MyLab 70 Xvision, Esaote. Results. Left peak atrial-longitudinal strain (LS was significantly reduced from T1 to T2 and from T2 to T3 (. Right peak atrial-LS and right ventricular-LS showed a significant reduction only at T3 (. Left ventricular-LS did not change significantly during titration of PEEP. Cardiac chambers’ volumes showed a significant reduction at higher levels of PEEP (. Conclusions. We demonstrated for the first time that incremental PEEP affects myocardial strain values obtained with STE in intubated critically ill patients. Whenever performing STE in mechanically ventilated patients, care must be taken when PEEP is higher than 10 cmH2O to avoid misinterpreting data and making erroneous decisions.

  20. Speckle interferometry of asteroids

    International Nuclear Information System (INIS)

    Drummond, J.

    1988-01-01

    By studying the image two-dimensional power spectra or autocorrelations projected by an asteroid as it rotates, it is possible to locate its rotational pole and derive its three axes dimensions through speckle interferometry under certain assumptions of uniform, geometric scattering, and triaxial ellipsoid shape. However, in cases where images can be reconstructed, the need for making the assumptions is obviated. Furthermore, the ultimate goal for speckle interferometry of image reconstruction will lead to mapping albedo features (if they exist) as impact areas or geological units. The first glimpses of the surface of an asteroid were obtained from images of 4 Vesta reconstructed from speckle interferometric observations. These images reveal that Vesta is quite Moon-like in having large hemispheric-scale albedo features. All of its lightcurves can be produced from a simple model developed from the images. Although undoubtedly more intricate than the model, Vesta's lightcurves can be matched by a model with three dark and four bright spots. The dark areas so dominate one hemisphere that a lightcurve minimum occurs when the maximum cross-section area is visible. The triaxial ellipsoid shape derived for Vesta is not consistent with the notion that the asteroid has an equilibrium shape in spite of its having apparently been differentiated

  1. A decade of innovation with laser speckle metrology

    Science.gov (United States)

    Ettemeyer, Andreas

    2003-05-01

    Speckle Pattern Interferometry has emerged from the experimental substitution of holographic interferometry to become a powerful problem solving tool in research and industry. The rapid development of computer and digital imaging techniques in combination with minaturization of the optical equipment led to new applications which had not been anticipated before. While classical holographic interferometry had always required careful consideration of the environmental conditions such as vibration, noise, light, etc. and could generally only be performed in the optical laboratory, it is now state of the art, to handle portable speckle measuring equipment at almost any place. During the last decade, the change in design and technique has dramatically influenced the range of applications of speckle metrology and opened new markets. The integration of recent research results into speckle measuring equipment has led to handy equipment, simplified the operation and created high quality data output.

  2. Statistical spatial properties of speckle patterns generated by multiple laser beams

    International Nuclear Information System (INIS)

    Le Cain, A.; Sajer, J. M.; Riazuelo, G.

    2011-01-01

    This paper investigates hot spot characteristics generated by the superposition of multiple laser beams. First, properties of speckle statistics are studied in the context of only one laser beam by computing the autocorrelation function. The case of multiple laser beams is then considered. In certain conditions, it is shown that speckles have an ellipsoidal shape. Analytical expressions of hot spot radii generated by multiple laser beams are derived and compared to numerical estimates made from the autocorrelation function. They are also compared to numerical simulations performed within the paraxial approximation. Excellent agreement is found for the speckle width as well as for the speckle length. Application to the speckle patterns generated in the Laser MegaJoule configuration in the zone where all the beams overlap is presented. Influence of polarization on the size of the speckles as well as on their abundance is studied.

  3. Abnormal maternal echocardiographic findings in triplet pregnancies presenting with dyspnoea.

    Science.gov (United States)

    Elhenicky, Marie; Distelmaier, Klaus; Mailath-Pokorny, Mariella; Worda, Christof; Langer, Martin; Worda, Katharina

    2016-03-01

    The objective of our study was to evaluate the prevalence of abnormal maternal echocardiographic findings in triplet pregnancies presenting with dyspnoea. Between 2003 and 2013, patients' records of 96 triplet pregnancies at our department were analysed including maternal and fetal outcome, echocardiographic parameters and N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels. After exclusion of triplet pregnancies with fetal demise before 23 + 0 weeks, selective feticide or missing outcome data, the study population consisted of 60 triplet pregnancies. All women with dyspnoea underwent echocardiography and measurement of NT-proBNP. Dyspnoea towards the end of pregnancy was observed in 13.3% (8/60) of all women with triplet pregnancies, and all of these women underwent echocardiography. The prevalence of abnormal echocardiographic findings in women with dyspnoea was 37.5% (3/8) with peripartum cardiomyopathy in one woman. Median serum NT-proBNP was significantly higher in women with abnormal echocardiographic findings compared with those without (1779 ng/ml, range 1045-6076 ng/ml vs 172 ng/ml, range 50-311 ng/ml; p presenting with dyspnoea show a high prevalence of abnormal echocardiographic findings. Since dyspnoea is a common sign in triplet pregnancies and is associated with a high rate of cardiac involvement, echocardiography and evaluation of maternal NT-proBNP could be considered to improve early diagnosis and perinatal management.

  4. Compound speckles and their statistical and dynamical properties

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner; Jakobsen, Michael Linde; Skov Hansen, Rene

    2008-01-01

    Two issues will be treated in this presentation, both focusing on gaining a deeper understanding of dynamic speckles, aiming at the use for probing dynamical properties of scattering structures. The first issue to be addressed is the dynamics of speckles arising from illuminating a solid surface...

  5. Speckle Suppression by Weighted Euclidean Distance Anisotropic Diffusion

    Directory of Open Access Journals (Sweden)

    Fengcheng Guo

    2018-05-01

    Full Text Available To better reduce image speckle noise while also maintaining edge information in synthetic aperture radar (SAR images, we propose a novel anisotropic diffusion algorithm using weighted Euclidean distance (WEDAD. Presented here is a modified speckle reducing anisotropic diffusion (SRAD method, which constructs a new edge detection operator using weighted Euclidean distances. The new edge detection operator can adaptively distinguish between homogenous and heterogeneous image regions, effectively generate anisotropic diffusion coefficients for each image pixel, and filter each pixel at different scales. Additionally, the effects of two different weighting methods (Gaussian weighting and non-linear weighting of de-noising were analyzed. The effect of different adjustment coefficient settings on speckle suppression was also explored. A series of experiments were conducted using an added noise image, GF-3 SAR image, and YG-29 SAR image. The experimental results demonstrate that the proposed method can not only significantly suppress speckle, thus improving the visual effects, but also better preserve the edge information of images.

  6. The POKEMON Speckle Survey of Nearby M-Dwarfs

    Science.gov (United States)

    van Belle, Gerard; von Braun, Kaspar; Horch, Elliott; Clark, Catherine; DSSI Speckle Team

    2018-01-01

    The POKEMON (Pervasive Overview of Kompanions of Every M-dwarf in Our Neighborhood) survey of nearby M-dwarfs intends to inspect, at diffraction-limited resolution, every low-mass star out to 15pc, along with selected additional objects to 25pc. The primary emphasis of the survey is detection of low-mass companions to these M-dwarfs for refinement of the low-mass star multiplicity rate. The resultant catalog of M-dwarf companions will also guide immediate refinement of transit planet detection results from surveys such as TESS. POKEMON is using Lowell Observatory's 4.3-m Discovery Channel Telescope (DCT) with the Differential Speckle Survey Instrument (DSSI) speckle camera, along with the NN-Explore Exoplanet Stellar Speckle Imager (NESSI) speckle imager on 3.5-m WIYN; the survey takes advantage of the extremely rapid observing cadence rates possible with WIYN and (especially) DCT. The current status and preliminary results from the first 20+ nights of observing will be presented. Gotta observe them all!

  7. Recent advances in echocardiography: strain and strain rate imaging [version 1; referees: 3 approved

    Directory of Open Access Journals (Sweden)

    Oana Mirea

    2016-04-01

    Full Text Available Deformation imaging by echocardiography is a well-established research tool which has been gaining interest from clinical cardiologists since the introduction of speckle tracking. Post-processing of echo images to analyze deformation has become readily available at the fingertips of the user. New parameters such as global longitudinal strain have been shown to provide added diagnostic value, and ongoing efforts of the imaging societies and industry aimed at harmonizing methods will improve the technique further. This review focuses on recent advances in the field of echocardiographic strain and strain rate imaging, and provides an overview on its current and potential future clinical applications.

  8. Strain and strain rate by two-dimensional speckle tracking echocardiography in a maned wolf Strain e strain rate por meio de ecocardiogratia speckle traking bidimensional em um lobo-guará

    Directory of Open Access Journals (Sweden)

    Matheus M. Mantovani

    2012-12-01

    Full Text Available The measurement of cardiovascular features of wild animals is important, as is the measurement in pets, for the assessment of myocardial function and the early detection of cardiac abnormalities, which could progress to heart failure. Speckle tracking echocardiography (2D STE is a new tool that has been used in veterinary medicine, which demonstrates several advantages, such as angle independence and the possibility to provide the early diagnosis of myocardial alterations. The aim of this study was to evaluate the left myocardial function in a maned wolf by 2D STE. Thus, the longitudinal, circumferential and radial strain and strain rate were obtained, as well as, the radial and longitudinal velocity and displacement values, from the right parasternal long axis four-chamber view, the left parasternal apical four chamber view and the parasternal short axis at the level of the papillary muscles. The results of the longitudinal variables were -13.52±7.88, -1.60±1.05, 4.34±2.52 and 3.86±3.04 for strain (%, strain rate (1/s, displacement (mm and velocity (cm/s, respectively. In addition, the radial and circumferential Strain and Strain rate were 24.39±14.23, 1.86±0.95 and -13.69±6.53, -1.01±0.48, respectively. Thus, the present study provides the first data regarding the use of this tool in maned wolves, allowing a more complete quantification of myocardial function in this species.A obtenção de parâmetros cardiovasculares em animais selvagens são importantes de serem avaliados, assim como em animais de companhia, para a obtenção da função miocárdica e determinação precoce de alterações cardíacas que poderiam evoluir para insuficiência cardíaca . A ecocardiografia speckle tracking (2D STE é uma ferramenta nova que tem sido utilizada em medicina veterinária, a qual tem demonstrado várias vantagens quanto ao seu uso, como a independência do ângulo de insonação e a possibilidade de se obter o diagnóstico precoce de altera

  9. Analyzing speckle contrast for HiLo microscopy optimization

    Science.gov (United States)

    Mazzaferri, J.; Kunik, D.; Belisle, J. M.; Singh, K.; Lefrançois, S.; Costantino, S.

    2011-07-01

    HiLo microscopy is a recently developed technique that provides both optical sectioning and fast imaging with a simple implementation and at a very low cost. The methodology combines widefield and speckled illumination images to obtain one optically sectioned image. Hence, the characteristics of such speckle illumination ultimately determine the quality of HiLo images and the overall performance of the method. In this work, we study how speckle contrast influence local variations of fluorescence intensity and brightness profiles of thick samples. We present this article as a guide to adjust the parameters of the system for optimizing the capabilities of this novel technology.

  10. Quantitative Evaluation of the Fetal Right and Left Ventricular Fractional Area Change Using Speckle Tracking Technology.

    Science.gov (United States)

    DeVore, Greggory R; Klas, Berthold; Satou, Gary; Sklansky, Mark

    2018-03-14

    The purpose of this study was to measure the fractional area change (FAC) of the right and left ventricles in normal fetal hearts between 20 and 40 weeks of gestation using speckle-tracking software. The 4-chamber view of the fetal heart was obtained in 200 control fetuses between 20 and 40 weeks of gestation. The FAC was computed from the ventricular areas [((end-diastolic area) - (end-systolic area)/(end-diastolic area)) x 100] for the right and left ventricles and regressed against 7 independent biometric and age variables. The FAC was correlated with longitudinal fractional shortening (LFS) [((end-diastolic longitudinal length) - (end-systolic longitudinal length) /(end-diastolic longitudinal length)) x 100] obtained from the mid ventricular basal-apical lengths of the right and left ventricular chambers and the transverse fractional shortening (TFS) [((end-diastolic transverse length) - (end-systolic transverse length)/(end-diastolic transverse length)) x 100] from three transverse positions (base, mid, apical) located within each ventricular chamber. To evaluate potential clinical utility, the FAC, LFS, and TFS results were examined in 9 fetuses with congenital heart defects (CHD). Regression analysis demonstrated significant associations between the FAC and the biometric and age independent variables (R 2 = 0.13 - 0.15). The FAC was significantly correlated with the LFS (R 2 =0.18 to 0.28) and TFS (R 2 = 0.13 to 0.33). The 9 fetuses with CHD illustrated the interrelationship between the FAC, LFS, and TFS when identifying abnormal ventricular function. This study reports results from measuring the FAC of the right and left ventricles, and demonstrates a correlation with longitudinal fractional shortening (LFS) and transverse fractional shortening (TFS). This article is protected by copyright. All rights reserved.

  11. Applications of polarization speckle in skin cancer detection and monitoring

    Science.gov (United States)

    Lee, Tim K.; Tchvialeva, Lioudmila; Phillips, Jamie; Louie, Daniel C.; Zhao, Jianhua; Wang, Wei; Lui, Harvey; Kalia, Sunil

    2018-01-01

    Polarization speckle is a rapidly developed field. Unlike laser speckle, polarization speckle consists of stochastic interference patterns with spatially random polarizations, amplitudes and phases. We have been working in this exciting research field, developing techniques to generate polarization patterns from skin. We hypothesize that polarization speckle patterns could be used in biomedical applications, especially, for detecting and monitoring skin cancers, the most common neoplasmas for white populations around the world. This paper describes our effort in developing two polarization speckle devices. One of them captures the Stokes parameters So and S1 simultaneously, and another one captures all four Stokes parameters So, S1, S2, and S3 in one-shot, within milliseconds. Hence these two devices could be used in medical clinics and assessed skin conditions in-vivo. In order to validate our hypothesis, we conducted a series of three clinical studies. These are early pilot studies, and the results suggest that the devices have potential to detect and monitor skin cancers.

  12. Speckle Imaging of Binary Stars with Large-Format CCDs

    Science.gov (United States)

    Horch, E.; Ninkov, Z.; Slawson, R. W.; van Altena, W. F.; Meyer, R. D.; Girard, T. M.

    1997-12-01

    In the past, bare (unintensified) CCDs have not been widely used in speckle imaging for two main reasons: 1) the readout rate of most scientific-grade CCDs is too slow to be able to observe at the high frame rates necessary to capture speckle patterns efficiently, and 2) the read noise of CCDs limits the detectability of fainter objects where it becomes difficult to distinguish between speckles and noise peaks in the image. These facts have led to the current supremacy of intensified imaging systems (such as intensified-CCDs) in this field, which can typically be read out at video rates or faster. We have developed a new approach that uses a large format CCD not only to detect the incident photons but also to record many speckle patterns before the chip is read out. This approach effectively uses the large area of the CCD as a physical ``memory cache'' of previous speckle data frames. The method is described, and binary star observations from the University of Toronto Southern Observatory 60-cm telescope and the Wisconsin-Indiana-Yale-NOAO (WIYN) 3.5-m telescope are presented. Plans for future observing and instrumentation improvements are also outlined.

  13. Dynamical speckles in watery surfaces

    International Nuclear Information System (INIS)

    Llovera-Gonzalez, J.J.; Moreno-Yeras, A.; Garcia-Diaz, M.; Alvarez-Salgado, Y.

    2009-01-01

    Recovery of watery surfaces with monolayer of surfactant substances is of interest in diverse technological applications. The format ion and study of molecular monolayer deposited in these surfaces require the application of measurements techniques that allow evaluating the recovery grade locally without modifying practically the studied surface. In this paper the preliminary results obtained by the authors it plows exposed applying the technique of dynamic speckle interferometry in watery surfaces and their consideration like to possible resource to measure the grade of local recovery of these surfaces on the it bases that the speckles pattern dog reveal the dynamics of evaporation that takes place in the same ones. (Author)

  14. Quantization analysis of speckle intensity measurements for phase retrieval

    DEFF Research Database (Denmark)

    Maallo, Anne Margarette S.; Almoro, Percival F.; Hanson, Steen Grüner

    2010-01-01

    Speckle intensity measurements utilized for phase retrieval (PR) are sequentially taken with a digital camera, which introduces quantization error that diminishes the signal quality. Influences of quantization on the speckle intensity distribution and PR are investigated numerically...... and experimentally in the static wavefront sensing setup. Resultsshowthat 3 to 4 bits are adequate to represent the speckle intensities and yield acceptable reconstructions at relatively fast convergence rates. Computer memory requirements may be eased down by 2.4 times if a 4 bit instead of an 8 bit camera is used...

  15. Effects of silicone expanders and implants on echocardiographic image quality after breast reconstruction.

    Science.gov (United States)

    Pignatti, Marco; Mantovani, Francesca; Bertelli, Luca; Barbieri, Andrea; Pacchioni, Lucrezia; Loschi, Pietro; De Santis, Giorgio

    2013-08-01

    Use of silicone expanders and implants is the most common breast reconstruction technique after mastectomy. Postmastectomy patients often need echocardiographic monitoring of potential cardiotoxicity induced by cancer chemotherapy. The impairment of the echocardiographic acoustic window caused by silicone implants for breast augmentation has been reported. This study investigates whether the echocardiographic image quality was impaired in women reconstructed with silicone expanders and implants. The records of 44 consecutive women who underwent echocardiographic follow-up after breast reconstruction with expanders and implants at the authors' institution from January of 2000 to August of 2012 were reviewed. The population was divided into a study group (left or bilateral breast expanders/implants, n=30) and a control group (right breast expanders/implants, n=14). The impact of breast expanders/implants on echocardiographic image quality was tested (analysis of covariance model). Patients with a breast expander/implant (left or bilateral and right breast expanders/implants) were included. The mean volume of the breast devices was 353.2±125.5 cc. The quality of the echocardiographic images was good or sufficient in the control group; in the study group, it was judged as adequate in only 50 percent of cases (15 patients) and inadequate in the remaining 15 patients (pimplants in postmastectomy left breast reconstruction considerably reduce the image quality of echocardiography. This may have important clinical implications, given the need for periodic echocardiographic surveillance before and during chemotherapy. Therapeutic, III.

  16. Overweight causes left ventricular diastolic asynchrony and diastolic dysfunction: a study based on speckle tracking echocardiography in healthy subjects.

    Science.gov (United States)

    Nakabachi, Masahiro; Mikami, Taisei; Okada, Kazunori; Onozuka, Hisao; Kaga, Sanae; Inoue, Mamiko; Yokoyama, Shinobu; Nishida, Mutsumi; Shimizu, Chikara; Matsuno, Kazuhiko; Iwano, Hiroyuki; Yamada, Satoshi; Tsutsui, Hiroyuki

    2012-09-01

    Left ventricular (LV) diastolic dysfunction is often observed in healthy subjects and can be a cause of heart failure with preserved ejection fraction (EF). We aimed to investigate the role of LV diastolic asynchrony as a cause of diastolic dysfunction in healthy subjects. In 40 healthy subjects, two-dimensional speckle tracking imaging (2DSTI) was performed to measure the peak early diastolic longitudinal strain rates (Esr) of the apical, mid-ventricular, and basal segments of the septum and posterior wall. A mean value of the Esr of the 6 segments (mEsr) was calculated. The time from aortic valve closure to the Esr was measured for each segment, and the standard deviation (SDTEsr) was calculated. The peak global early diastolic strain rate (gEsr) was measured with a region of interest (ROI) on the whole LV myocardium. LV flow propagation velocity (FPV) was measured using conventional Doppler techniques. SDTEsr was not correlated with age, but was significantly correlated with body mass index (BMI) (r = 0.41, p < 0.01). Although no significant correlation was observed between mEsr and FPV, gEsr and SDTEsr significantly correlated with FPV (r = 0.41, p < 0.01; r = -0.54, p < 0.001). As a result of the multiple regression analysis, SDTEsr was the single determinant of FPV. Diastolic asynchrony, associated with overweight but not with aging, may contribute to diastolic dysfunction in healthy subjects.

  17. Modeling laser speckle imaging of perfusion in the skin (Conference Presentation)

    Science.gov (United States)

    Regan, Caitlin; Hayakawa, Carole K.; Choi, Bernard

    2016-02-01

    Laser speckle imaging (LSI) enables visualization of relative blood flow and perfusion in the skin. It is frequently applied to monitor treatment of vascular malformations such as port wine stain birthmarks, and measure changes in perfusion due to peripheral vascular disease. We developed a computational Monte Carlo simulation of laser speckle contrast imaging to quantify how tissue optical properties, blood vessel depths and speeds, and tissue perfusion affect speckle contrast values originating from coherent excitation. The simulated tissue geometry consisted of multiple layers to simulate the skin, or incorporated an inclusion such as a vessel or tumor at different depths. Our simulation used a 30x30mm uniform flat light source to optically excite the region of interest in our sample to better mimic wide-field imaging. We used our model to simulate how dynamically scattered photons from a buried blood vessel affect speckle contrast at different lateral distances (0-1mm) away from the vessel, and how these speckle contrast changes vary with depth (0-1mm) and flow speed (0-10mm/s). We applied the model to simulate perfusion in the skin, and observed how different optical properties, such as epidermal melanin concentration (1%-50%) affected speckle contrast. We simulated perfusion during a systolic forearm occlusion and found that contrast decreased by 35% (exposure time = 10ms). Monte Carlo simulations of laser speckle contrast give us a tool to quantify what regions of the skin are probed with laser speckle imaging, and measure how the tissue optical properties and blood flow affect the resulting images.

  18. Momentum transfer Monte Carlo for the simulation of laser speckle imaging and its application in the skin.

    Science.gov (United States)

    Regan, Caitlin; Hayakawa, Carole; Choi, Bernard

    2017-12-01

    Due to its simplicity and low cost, laser speckle imaging (LSI) has achieved widespread use in biomedical applications. However, interpretation of the blood-flow maps remains ambiguous, as LSI enables only limited visualization of vasculature below scattering layers such as the epidermis and skull. Here, we describe a computational model that enables flexible in-silico study of the impact of these factors on LSI measurements. The model uses Monte Carlo methods to simulate light and momentum transport in a heterogeneous tissue geometry. The virtual detectors of the model track several important characteristics of light. This model enables study of LSI aspects that may be difficult or unwieldy to address in an experimental setting, and enables detailed study of the fundamental origins of speckle contrast modulation in tissue-specific geometries. We applied the model to an in-depth exploration of the spectral dependence of speckle contrast signal in the skin, the effects of epidermal melanin content on LSI, and the depth-dependent origins of our signal. We found that LSI of transmitted light allows for a more homogeneous integration of the signal from the entire bulk of the tissue, whereas epi-illumination measurements of contrast are limited to a fraction of the light penetration depth. We quantified the spectral depth dependence of our contrast signal in the skin, and did not observe a statistically significant effect of epidermal melanin on speckle contrast. Finally, we corroborated these simulated results with experimental LSI measurements of flow beneath a thin absorbing layer. The results of this study suggest the use of LSI in the clinic to monitor perfusion in patients with different skin types, or inhomogeneous epidermal melanin distributions.

  19. Deformation measurements of materials at low temperatures using laser speckle photography method

    International Nuclear Information System (INIS)

    Sumio Nakahara; Yukihide Maeda; Kazunori Matsumura; Shigeyoshi Hisada; Takeyoshi Fujita; Kiyoshi Sugihara

    1992-01-01

    The authors observed deformations of several materials during cooling down process from room temperature to liquid nitrogen temperature using the laser speckle photography method. The in-plane displacements were measured by the image plane speckle photography and the out-of-plane displacement gradients by the defocused speckle photography. The results of measurements of in-plane displacement are compared with those of FEM analysis. The applicability of laser speckle photography method to cryogenic engineering are also discussed

  20. Speckle tracking echocardiography derived 2-dimensional myocardial strain predicts left ventricular function and mass regression in aortic stenosis patients undergoing aortic valve replacement.

    Science.gov (United States)

    Staron, Adam; Bansal, Manish; Kalakoti, Piyush; Nakabo, Ayumi; Gasior, Zbigniew; Pysz, Piotr; Wita, Krystian; Jasinski, Marek; Sengupta, Partho P

    2013-04-01

    Regression of left ventricular (LV) mass in severe aortic stenosis (AS) following aortic valve replacement (AVR) reduces the potential risk of sudden death and congestive heart failure associated with LV hypertrophy. We investigated whether abnormalities of resting LV deformation in severe AS can predict the lack of regression of LV mass following AVR. Two-dimensional speckle tracking echocardiography (STE) was performed in a total of 100 subjects including 60 consecutive patients with severe AS having normal LV ejection fraction (EF > 50 %) and 40 controls. STE was performed preoperatively and at 4 months following AVR, including longitudinal strain assessed from the apical 4-chamber and 2-chamber views and the circumferential and rotational mechanics measured from the apical short axis view. In comparison with controls, the patients with AS showed a significantly lower LV longitudinal (p regression (>10 %) following AVR. In conclusion, STE can quantify the burden of myocardial dysfunction in patients with severe AS despite the presence of normal LV ejection fraction. Furthermore, resting abnormalities in circumferential strain at LV apex is related with a hemodynamic milieu associated with the lack of LV mass regression during short-term follow up after AVR.

  1. Ultrasound speckle reduction based on fractional order differentiation.

    Science.gov (United States)

    Shao, Dangguo; Zhou, Ting; Liu, Fan; Yi, Sanli; Xiang, Yan; Ma, Lei; Xiong, Xin; He, Jianfeng

    2017-07-01

    Ultrasound images show a granular pattern of noise known as speckle that diminishes their quality and results in difficulties in diagnosis. To preserve edges and features, this paper proposes a fractional differentiation-based image operator to reduce speckle in ultrasound. An image de-noising model based on fractional partial differential equations with balance relation between k (gradient modulus threshold that controls the conduction) and v (the order of fractional differentiation) was constructed by the effective combination of fractional calculus theory and a partial differential equation, and the numerical algorithm of it was achieved using a fractional differential mask operator. The proposed algorithm has better speckle reduction and structure preservation than the three existing methods [P-M model, the speckle reducing anisotropic diffusion (SRAD) technique, and the detail preserving anisotropic diffusion (DPAD) technique]. And it is significantly faster than bilateral filtering (BF) in producing virtually the same experimental results. Ultrasound phantom testing and in vivo imaging show that the proposed method can improve the quality of an ultrasound image in terms of tissue SNR, CNR, and FOM values.

  2. Multimode waveguide speckle patterns for compressive sensing.

    Science.gov (United States)

    Valley, George C; Sefler, George A; Justin Shaw, T

    2016-06-01

    Compressive sensing (CS) of sparse gigahertz-band RF signals using microwave photonics may achieve better performances with smaller size, weight, and power than electronic CS or conventional Nyquist rate sampling. The critical element in a CS system is the device that produces the CS measurement matrix (MM). We show that passive speckle patterns in multimode waveguides potentially provide excellent MMs for CS. We measure and calculate the MM for a multimode fiber and perform simulations using this MM in a CS system. We show that the speckle MM exhibits the sharp phase transition and coherence properties needed for CS and that these properties are similar to those of a sub-Gaussian MM with the same mean and standard deviation. We calculate the MM for a multimode planar waveguide and find dimensions of the planar guide that give a speckle MM with a performance similar to that of the multimode fiber. The CS simulations show that all measured and calculated speckle MMs exhibit a robust performance with equal amplitude signals that are sparse in time, in frequency, and in wavelets (Haar wavelet transform). The planar waveguide results indicate a path to a microwave photonic integrated circuit for measuring sparse gigahertz-band RF signals using CS.

  3. Statistics of polarization speckle: theory versus experiment

    DEFF Research Database (Denmark)

    Wang, Wei; Hanson, Steen Grüner; Takeda, Mitsuo

    2010-01-01

    In this paper, we reviewed our recent work on the statistical properties of polarization speckle, described by stochastic Stokes parameters fluctuating in space. Based on the Gaussian assumption for the random electric field components and polar-interferometer, we investigated theoretically...... and experimentally the statistics of Stokes parameters of polarization speckle, including probability density function of Stokes parameters with the spatial degree of polarization, autocorrelation of Stokes vector and statistics of spatial derivatives for Stokes parameters....

  4. Left ventricular noncompaction: Clinical-echocardiographic study

    Directory of Open Access Journals (Sweden)

    Nikolić Aleksandra

    2012-01-01

    Full Text Available Background/Aim. Left ventricular noncompaction (LVNC is a disorder in endomyocardial morphogenesis, seen either isolated (in the absence of other cardiac anomalies or in association with congenital heart disease and some neuromuscular diseases. Intrauterine arrest of the compaction of myocardial fibers is postulated to be the reason of LVNC. Recognition of this condition is extremely important due to its high mortality and morbidity that lead to progressive heart failure, ventricular arrhythmias and thromboembolic events. The aim of this study was to determine the prevalence and clinical presentation of LVNC among consecutive outpatients according to clinical and echocardiographyic findings. Methode. A total of 3,854 consecutive patients examined at the Institute for Cardiovascular Diseases within a period January 2006 - January 2007 were included in the study. All the patients underwent echocardiographic examination using the same equipment (Vivid 7, GE Medical System. Echocardiographic parameters and clinical presentation in patients with echocardiographic criteria for LVNC were analyzed. Results. Analyzing 3,854 consecutive outpatients, using two-dimensional Color Doppler echocardiography from January 2006 to January 2007, 12 patients met the criteria for LVNC. Seven of them were male. The mean age at diagnosis was 45 ± 15 years. Analyzing clinical manifestation of LVNC it was found that seven patients had signs of heart failure, six had arrhythmias with no embolic events. Conclusion. Our results suggest that the real prevalence of LVNC may be higher than expected. New studies have to be done to solve this problem.

  5. An echocardiographic study of healthy Border Collies with normal reference ranges for the breed.

    Science.gov (United States)

    Jacobson, Jake H; Boon, June A; Bright, Janice M

    2013-06-01

    The objectives of this study were to obtain standard echocardiographic measurements from healthy Border Collies and to compare these measurements to those previously reported for a general population of dogs. Standard echocardiographic data were obtained from twenty apparently healthy Border Collie dogs. These data (n = 20) were compared to data obtained from a general population of healthy dogs (n = 69). Border Collies were deemed healthy based on normal history, physical examination, complete blood count, serum biochemical profile, electrocardiogram, and blood pressure, with no evidence of congenital or acquired heart disease on echocardiographic examination. Standard two dimensional, M-mode, and Doppler echocardiographic measurements were obtained and normal ranges determined. The data were compared to data previously obtained at our hospital from a general population of normal dogs. Two dimensional, M-mode, and Doppler reference ranges for healthy Border Collies are presented in tabular form. Comparison of the weight adjusted M-mode echocardiographic means from Border Collies to those from the general population of dogs showed Border Collies to have larger left ventricular systolic and diastolic dimensions, smaller interventricular septal thickness, and lower fractional shortening. There are differences in some echocardiographic parameters between healthy Border Collies and the general dog population, and the echocardiographic reference ranges provided in this study should be used as breed specific reference values for Border Collies. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. 2-D left ventricular flow estimation by combining speckle tracking with Navier-Stokes-based regularization: an in silico, in vitro and in vivo study.

    Science.gov (United States)

    Gao, Hang; Bijnens, Nathalie; Coisne, Damien; Lugiez, Mathieu; Rutten, Marcel; D'hooge, Jan

    2015-01-01

    Despite the availability of multiple ultrasound approaches to left ventricular (LV) flow characterization in two dimensions, this technique remains in its childhood and further developments seem warranted. This article describes a new methodology for tracking the 2-D LV flow field based on ultrasound data. Hereto, a standard speckle tracking algorithm was modified by using a dynamic kernel embedding Navier-Stokes-based regularization in an iterative manner. The performance of the proposed approach was first quantified in synthetic ultrasound data based on a computational fluid dynamics model of LV flow. Next, an experimental flow phantom setup mimicking the normal human heart was used for experimental validation by employing simultaneous optical particle image velocimetry as a standard reference technique. Finally, the applicability of the approach was tested in a clinical setting. On the basis of the simulated data, pointwise evaluation of the estimated velocity vectors correlated well (mean r = 0.84) with the computational fluid dynamics measurement. During the filling period of the left ventricle, the properties of the main vortex obtained from the proposed method were also measured, and their correlations with the reference measurement were also calculated (radius, r = 0.96; circulation, r = 0.85; weighted center, r = 0.81). In vitro results at 60 bpm during one cardiac cycle confirmed that the algorithm properly measures typical characteristics of the vortex (radius, r = 0.60; circulation, r = 0.81; weighted center, r = 0.92). Preliminary qualitative results on clinical data revealed physiologic flow fields. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. Real-time acquisition and display of flow contrast using speckle variance optical coherence tomography in a graphics processing unit.

    Science.gov (United States)

    Xu, Jing; Wong, Kevin; Jian, Yifan; Sarunic, Marinko V

    2014-02-01

    In this report, we describe a graphics processing unit (GPU)-accelerated processing platform for real-time acquisition and display of flow contrast images with Fourier domain optical coherence tomography (FDOCT) in mouse and human eyes in vivo. Motion contrast from blood flow is processed using the speckle variance OCT (svOCT) technique, which relies on the acquisition of multiple B-scan frames at the same location and tracking the change of the speckle pattern. Real-time mouse and human retinal imaging using two different custom-built OCT systems with processing and display performed on GPU are presented with an in-depth analysis of performance metrics. The display output included structural OCT data, en face projections of the intensity data, and the svOCT en face projections of retinal microvasculature; these results compare projections with and without speckle variance in the different retinal layers to reveal significant contrast improvements. As a demonstration, videos of real-time svOCT for in vivo human and mouse retinal imaging are included in our results. The capability of performing real-time svOCT imaging of the retinal vasculature may be a useful tool in a clinical environment for monitoring disease-related pathological changes in the microcirculation such as diabetic retinopathy.

  8. Simulations of multi-contrast x-ray imaging using near-field speckles

    Energy Technology Data Exchange (ETDEWEB)

    Zdora, Marie-Christine [Lehrstuhl für Biomedizinische Physik, Physik-Department & Institut für Medizintechnik, Technische Universität München, 85748 Garching (Germany); Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom and Department of Physics & Astronomy, University College London, London, WC1E 6BT (United Kingdom); Thibault, Pierre [Department of Physics & Astronomy, University College London, London, WC1E 6BT (United Kingdom); Herzen, Julia; Pfeiffer, Franz [Lehrstuhl für Biomedizinische Physik, Physik-Department & Institut für Medizintechnik, Technische Universität München, 85748 Garching (Germany); Zanette, Irene [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE (United Kingdom); Lehrstuhl für Biomedizinische Physik, Physik-Department & Institut für Medizintechnik, Technische Universität München, 85748 Garching (Germany)

    2016-01-28

    X-ray dark-field and phase-contrast imaging using near-field speckles is a novel technique that overcomes limitations inherent in conventional absorption x-ray imaging, i.e. poor contrast for features with similar density. Speckle-based imaging yields a wealth of information with a simple setup tolerant to polychromatic and divergent beams, and simple data acquisition and analysis procedures. Here, we present a simulation software used to model the image formation with the speckle-based technique, and we compare simulated results on a phantom sample with experimental synchrotron data. Thorough simulation of a speckle-based imaging experiment will help for better understanding and optimising the technique itself.

  9. Contour extraction of echocardiographic images based on pre-processing

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Zinah Rajab; Rahmat, Rahmita Wirza; Abdullah, Lili Nurliyana [Department of Multimedia, Faculty of Computer Science and Information Technology, Department of Computer and Communication Systems Engineering, Faculty of Engineering University Putra Malaysia 43400 Serdang, Selangor (Malaysia); Zamrin, D M [Department of Surgery, Faculty of Medicine, National University of Malaysia, 56000 Cheras, Kuala Lumpur (Malaysia); Saripan, M Iqbal

    2011-02-15

    In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

  10. Contour extraction of echocardiographic images based on pre-processing

    International Nuclear Information System (INIS)

    Hussein, Zinah Rajab; Rahmat, Rahmita Wirza; Abdullah, Lili Nurliyana; Zamrin, D M; Saripan, M Iqbal

    2011-01-01

    In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

  11. Signal-to-noise based local decorrelation compensation for speckle interferometry applications

    International Nuclear Information System (INIS)

    Molimard, Jerome; Cordero, Raul; Vautrin, Alain

    2008-01-01

    Speckle-based interferometric techniques allow assessing the whole-field deformation induced on a specimen due to the application of load. These high sensitivity optical techniques yield fringe images generated by subtracting speckle patterns captured while the specimen undergoes deformation. The quality of the fringes, and in turn the accuracy of the deformation measurements, strongly depends on the speckle correlation. Specimen rigid body motion leads to speckle decorrelation that, in general, cannot be effectively counteracted by applying a global translation to the involved speckle patterns. In this paper, we propose a recorrelation procedure based on the application of locally evaluated translations. The proposed procedure implies dividing the field into several regions, applying a local translation, and calculating, in every region, the signal-to-noise ratio (SNR). Since the latter is a correlation indicator (the noise increases with the decorrelation) we argue that the proper translation is that which maximizes the locally evaluated SNR. The search of the proper local translations is, of course, an interactive process that can be facilitated by using a SNR optimization algorithm. The performance of the proposed recorrelation procedure was tested on two examples. First, the SNR optimization algorithm was applied to fringe images obtained by subtracting simulated speckle patterns. Next, it was applied to fringe images obtained by using a shearography optical setup from a specimen subjected to mechanical deformation. Our results show that the proposed SNR optimization method can significantly improve the reliability of measurements performed by using speckle-based techniques

  12. Spatial filtering velocimetry of objective speckles for measuring out-of-plane motion

    DEFF Research Database (Denmark)

    Jakobsen, Michael Linde; Yura, H. T.; Hanson, Steen Grüner

    2012-01-01

    This paper analyzes the dynamics of objective laser speckles as the distance between the object and the observation plane continuously changes. With the purpose of applying optical spatial filtering velocimetry to the speckle dynamics, in order to measure out-of-plane motion in real time......, a rotational symmetric spatial filter is designed. The spatial filter converts the speckle dynamics into a photocurrent with a quasi-sinusoidal response to the out-of-plane motion. The spatial filter is here emulated with a CCD camera, and is tested on speckles arising from a real application. The analysis...

  13. Laser Speckle Contrast Imaging: theory, instrumentation and applications.

    Science.gov (United States)

    Senarathna, Janaka; Rege, Abhishek; Li, Nan; Thakor, Nitish V

    2013-01-01

    Laser Speckle Contrast Imaging (LSCI) is a wide field of view, non scanning optical technique for observing blood flow. Speckles are produced when coherent light scattered back from biological tissue is diffracted through the limiting aperture of focusing optics. Mobile scatterers cause the speckle pattern to blur; a model can be constructed by inversely relating the degree of blur, termed speckle contrast to the scatterer speed. In tissue, red blood cells are the main source of moving scatterers. Therefore, blood flow acts as a virtual contrast agent, outlining blood vessels. The spatial resolution (~10 μm) and temporal resolution (10 ms to 10 s) of LSCI can be tailored to the application. Restricted by the penetration depth of light, LSCI can only visualize superficial blood flow. Additionally, due to its non scanning nature, LSCI is unable to provide depth resolved images. The simple setup and non-dependence on exogenous contrast agents have made LSCI a popular tool for studying vascular structure and blood flow dynamics. We discuss the theory and practice of LSCI and critically analyze its merit in major areas of application such as retinal imaging, imaging of skin perfusion as well as imaging of neurophysiology.

  14. Two-Dimensional Speckle Tracking Echocardiography Detects Subclinical Left Ventricular Systolic Dysfunction among Adult Survivors of Childhood, Adolescent, and Young Adult Cancer

    Directory of Open Access Journals (Sweden)

    Anthony F. Yu

    2016-01-01

    Full Text Available Two-dimensional speckle tracking echocardiography (2DSTE provides a sensitive measure of left ventricular (LV systolic function and may aid in the diagnosis of cardiotoxicity. 2DSTE was performed in a cross-sectional study of 134 patients (mean age: 31.4±8.8 years; 55% male; mean time since diagnosis: 15.4±9.4 years previously treated with anthracyclines (mean cumulative dose: 320±124 mg/m2, with (n=52 or without (n=82 mediastinal radiotherapy. The prevalence of LV systolic dysfunction, defined as fractional shortening < 27%, LV ejection fraction (LVEF < 55%, and global longitudinal strain (GLS ≤ 16%, was 5.2%, 6.0%, and 23.1%, respectively. Abnormal GLS was observed in 24 (18% patients despite a normal LVEF. Indices of LV systolic function were similar regardless of anthracycline dose. However, GLS was worse (18.0 versus 19.0, p=0.003 and prevalence of abnormal GLS was higher (36.5% versus 14.6%, p=0.004 in patients treated with mediastinal radiotherapy. Mediastinal radiotherapy was associated with reduced GLS (p=0.040 after adjusting for sex, age, and cumulative anthracycline dose. In adult survivors of childhood, adolescent, and young adult cancer, 2DSTE frequently detects LV systolic dysfunction despite a normal LVEF and may be useful for the long-term cardiac surveillance of adult cancer survivors.

  15. Strain bidimensional na cardiopatia de Takotsubo Two-dimensional strain in Takotsubo cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Carlos Bellini G. Gomes

    2010-08-01

    Full Text Available Este relato apresenta o seguimento tardio de um caso de cardiomiopatia de Takotsubo com boa evolução clínica e melhora da função sistólica global ventricular esquerda. Contudo, observou-se persistência de significativa disfunção sistólica regional longitudinal que foi avaliada por meio de nova técnica ecocardiográfica (speckle tracking, com as medidas do strain (S e strain rate (SR correspondentes. Ressaltamos a importância desse novo método para o acompanhamento dessa cardiopatia, pois permite identificar os pacientes que persistem com disfunção sistólica e que possivelmente serão beneficiados com a manutenção da terapêutica clínica.This report presents the late follow-up of a case of Takotsubo cardiomyopathy with good clinical outcome and improved left ventricular global systolic function. However, there was persistence of significant regional longitudinal systolic dysfunction evaluated using a new echocardiographic technique (speckle tracking, with corresponding measures of strain (S and strain rate (SR. We emphasize the importance of this new method to monitoring this cardiomyopathy, since it identifies patients with persistent systolic dysfunction who will possibly benefit from maintenance of clinical therapy

  16. Enhanced deterministic phase retrieval using a partially developed speckle field

    DEFF Research Database (Denmark)

    Almoro, Percival F.; Waller, Laura; Agour, Mostafa

    2012-01-01

    A technique for enhanced deterministic phase retrieval using a partially developed speckle field (PDSF) and a spatial light modulator (SLM) is demonstrated experimentally. A smooth test wavefront impinges on a phase diffuser, forming a PDSF that is directed to a 4f setup. Two defocused speckle...... intensity measurements are recorded at the output plane corresponding to axially-propagated representations of the PDSF in the input plane. The speckle intensity measurements are then used in a conventional transport of intensity equation (TIE) to reconstruct directly the test wavefront. The PDSF in our...

  17. The importance of speckle tracking echocardiography in the early detection of left ventricular dysfunction in patients with polycystic ovary syndrome.

    Science.gov (United States)

    Demirelli, Selami; Degirmenci, Husnu; Ermis, Emrah; Inci, Sinan; Nar, Gokay; Ayhan, Mehmet Emin; Fırtına, Serdar; Hamur, Hikmet; Durmaz, Senay Arikan

    2015-10-19

    Polycystic ovary syndrome (PCOS) is characterized by hormonal and metabolic abnormalities and is thought to increase a risk for cardiovascular diseases. In this study we use speckle tracking echocardiography (STE) to evaluate left ventricular (LV) dysfunction in the early period of the disease. We enrolled 31 patients with PCOS and 32 healthy volunteers as a control group. The participants' ages ranged between 18 and 40 years. PCOS was diagnosed according to the Rotterdam criteria. LV strain (LS) and strain rate (SR) were evaluated using apical two-chamber (2C), three-chamber (3C), and four-chamber (4C) imaging. Global LS and SR were calculated as average of three apical views. The waist-to-hip ratio, homeostasis model assessment-insulin resistance (HOMA-IR), and fasting insulin and triglyceride levels were higher in the PCOS group than in the controls (p=0.001, p=0.001, p=0.001, and p=0.005, respectively). In the PCOS group, the mitral A wave, deceleration time (DT), and isovolumetric relaxation time (IVRT) were significantly higher than in the controls (all pPCOS patient group (both p= 0.001). There were strong negative correlations between GLS and both fasting insulin (r=-0.64) and DT (r=-0.62) (both pPCOS patients had decreased LV function using STE. Therefore, STE imaging appears to be useful for the early detection of subclinical LV dysfunction in patients with PCOS.

  18. The Magnetic Nanoparticle Movement in Magnetic Fluid Characterized by the Laser Dynamic Speckle Interferometry

    Directory of Open Access Journals (Sweden)

    Xijun Wang

    2014-01-01

    Full Text Available A dual scanning laser speckle interferometry experiment was designed to observe the dynamic behavior of the magnetic fluid actuated by a magnetic field. In order to improve the spatial resolution of the dynamic speckle measurement, the phase delay scanning was used to compensate the additional phase variation which was caused by the transverse scanning. The correlation coefficients corresponding to the temporal dynamic speckle patterns within the same time interval scattering from the nanoparticles were calculated in the experiment on nanoscale magnetic clusters. In the experiment, the speckle of the magnetic nanoparticle fluid movement has been recorded by the lens unmounted CCD within the interferometry strips, although the speckle led to the distinguished annihilation of the light coherence. The results have showed that the nanoparticle fluid dynamic properties appeared synergistically in the fringe speckles. The analyses of the nanoparticle's relative speed and the speckle pattern moving amount in the fringes have proved the nanoparticle’s movement in a laminar flow in the experiment.

  19. Echocardiographic evaluation during weaning from mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Luciele Medianeira Schifelbain

    2011-01-01

    Full Text Available INTRODUCTION: Echocardiographic, electrocardiographic and other cardiorespiratory variables can change during weaning from mechanical ventilation. OBJECTIVES: To analyze changes in cardiac function, using Doppler echocardiogram, in critical patients during weaning from mechanical ventilation, using two different weaning methods: pressure support ventilation and T-tube; and comparing patient subgroups: success vs. failure in weaning. METHODS: Randomized crossover clinical trial including patients under mechanical ventilation for more than 48 h and considered ready for weaning. Cardiorespiratory variables, oxygenation, electrocardiogram and Doppler echocardiogram findings were analyzed at baseline and after 30 min in pressure support ventilation and T-tube. Pressure support ventilation vs. T-tube and weaning success vs. failure were compared using ANOVA and Student's t-test. The level of significance was p<0.05. RESULTS: Twenty-four adult patients were evaluated. Seven patients failed at the first weaning attempt. No echocardiographic or electrocardiographic differences were observed between pressure support ventilation and T-tube. Weaning failure patients presented increases in left atrium, intraventricular septum thickness, posterior wall thickness and diameter of left ventricle and shorter isovolumetric relaxation time. Successfully weaned patients had higher levels of oxygenation. CONCLUSION: No differences were observed between Doppler echocardiographic variables and electrocardiographic and other cardiorespiratory variables during pressure support ventilation and T-tube. However cardiac structures were smaller, isovolumetric relaxation time was larger, and oxygenation level was greater in successfully weaned patients

  20. A practical approach to optimizing the preparation of speckle patterns for digital-image correlation

    International Nuclear Information System (INIS)

    Lionello, Giacomo; Cristofolini, Luca

    2014-01-01

    The quality of strain measurements by digital image correlation (DIC) strongly depends on the quality of the pattern on the specimen’s surface. An ideal pattern should be highly contrasted, stochastic, and isotropic. In addition, the speckle pattern should have an average size that exceeds the image pixel size by a factor of 3–5. (Smaller speckles cause poor contrast, and larger speckles cause poor spatial resolution.) Finally, the ideal pattern should have a limited scatter in terms of speckle sizes. The aims of this study were: (i) to define the ideal speckle size in relation to the specimen size and acquisition system; (ii) provide practical guidelines to identify the optimal settings of an airbrush gun, in order to produce a pattern that is as close as possible to the desired one while minimizing the scatter of speckle sizes. Patterns of different sizes were produced using two different airbrush guns with different settings of the four most influential factors (dilution, airflow setting, spraying distance, and air pressure). A full-factorial DOE strategy was implemented to explore the four factors at two levels each: 36 specimens were analyzed for each of the 16 combinations. The images were acquired using the digital cameras of a DIC system. The distribution of speckle sizes was analyzed to calculate the average speckle size and the standard deviation of the corresponding truncated Gaussian distribution. A mathematical model was built to enable prediction of the average speckle size in relation to the airbrush gun settings. We showed that it is possible to obtain a pattern with a highly controlled average and a limited scatter of speckle sizes, so as to match the ideal distribution of speckle sizes for DIC. Although the settings identified here apply only to the specific equipment being used, this method can be adapted to any airbrush to produce a desired speckle pattern. (technical design note)

  1. Speckle tracking in a phantom and feature-based tracking in liver in the presence of respiratory motion using 4D ultrasound

    International Nuclear Information System (INIS)

    Harris, Emma J; Miller, Naomi R; Bamber, Jeffrey C; Symonds-Tayler, J Richard N; Evans, Philip M

    2010-01-01

    We have evaluated a 4D ultrasound-based motion tracking system developed for tracking of abdominal organs during therapy. Tracking accuracy and precision were determined using a tissue-mimicking phantom, by comparing tracked motion with known 3D sinusoidal motion. The feasibility of tracking 3D liver motion in vivo was evaluated by acquiring 4D ultrasound data from four healthy volunteers. For two of these volunteers, data were also acquired whilst simultaneously measuring breath flow using a spirometer. Hepatic blood vessels, tracked off-line using manual tracking, were used as a reference to assess, in vivo, two types of automated tracking algorithm: incremental (from one volume to the next) and non-incremental (from the first volume to each subsequent volume). For phantom-based experiments, accuracy and precision (RMS error and SD) were found to be 0.78 mm and 0.54 mm, respectively. For in vivo measurements, mean absolute distance and standard deviation of the difference between automatically and manually tracked displacements were less than 1.7 mm and 1 mm respectively in all directions (left-right, anterior-posterior and superior-inferior). In vivo non-incremental tracking gave the best agreement. In both phantom and in vivo experiments, tracking performance was poorest for the elevational component of 3D motion. Good agreement between automatically and manually tracked displacements indicates that 4D ultrasound-based motion tracking has potential for image guidance applications in therapy.

  2. Multi-wavelength speckle reduction for laser pico-projectors using diffractive optics

    Science.gov (United States)

    Thomas, Weston H.

    Personal electronic devices, such as cell phones and tablets, continue to decrease in size while the number of features and add-ons keep increasing. One particular feature of great interest is an integrated projector system. Laser pico-projectors have been considered, but the technology has not been developed enough to warrant integration. With new advancements in diode technology and MEMS devices, laser-based projection is currently being advanced for pico-projectors. A primary problem encountered when using a pico-projector is coherent interference known as speckle. Laser speckle can lead to eye irritation and headaches after prolonged viewing. Diffractive optical elements known as diffusers have been examined as a means to lower speckle contrast. Diffusers are often rotated to achieve temporal averaging of the spatial phase pattern provided by diffuser surface. While diffusers are unable to completely eliminate speckle, they can be utilized to decrease the resultant contrast to provide a more visually acceptable image. This dissertation measures the reduction in speckle contrast achievable through the use of diffractive diffusers. A theoretical Fourier optics model is used to provide the diffuser's stationary and in-motion performance in terms of the resultant contrast level. Contrast measurements of two diffractive diffusers are calculated theoretically and compared with experimental results. In addition, a novel binary diffuser design based on Hadamard matrices will be presented. Using two static in-line Hadamard diffusers eliminates the need for rotation or vibration of the diffuser for temporal averaging. Two Hadamard diffusers were fabricated and contrast values were subsequently measured, showing good agreement with theory and simulated values. Monochromatic speckle contrast values of 0.40 were achieved using the Hadamard diffusers. Finally, color laser projection devices require the use of red, green, and blue laser sources; therefore, using a

  3. Speckle Interferometry with the McMath-Pierce East Auxiliary Telescope

    Science.gov (United States)

    Harshaw, Richard; Ray, Jimmy; Douglass, David; Prause, Lori; Genet, Russell

    2015-09-01

    Engineering runs and tests on the McMath-Pierce 0.8 meter East Auxiliary telescope successfully configured the telescope for speckle interferometry observations of close visual double stars. This paper reports the procedure and results of the speckle analysis of four double stars.

  4. Clinical Electrocardiographic and Echocardiographic Features of ...

    African Journals Online (AJOL)

    Clinical Electrocardiographic and Echocardiographic Features of Atrial Fibrillation in Nigerians: An Analysis of 39 Patients Seen at the Lagos University Teaching Hospital. ... Congestive cardiac failure was present in 74% of the subjects with a mean NYHA class of about III. Embolic phenomenon was observed in 15% of the ...

  5. Accuracy concerns in digital speckle photography combined with Fresnel digital holographic interferometry

    Science.gov (United States)

    Zhao, Yuchen; Zemmamouche, Redouane; Vandenrijt, Jean-François; Georges, Marc P.

    2018-05-01

    A combination of digital holographic interferometry (DHI) and digital speckle photography (DSP) allows in-plane and out-of-plane displacement measurement between two states of an object. The former can be determined by correlating the two speckle patterns whereas the latter is given by the phase difference obtained from DHI. We show that the amplitude of numerically reconstructed object wavefront obtained from Fresnel in-line digital holography (DH), in combination with phase shifting techniques, can be used as speckle patterns in DSP. The accuracy of in-plane measurement is improved after correcting the phase errors induced by reference wave during reconstruction process. Furthermore, unlike conventional imaging system, Fresnel DH offers the possibility to resize the pixel size of speckle patterns situated on the reconstruction plane under the same optical configuration simply by zero-padding the hologram. The flexibility of speckle size adjustment in Fresnel DH ensures the accuracy of estimation result using DSP.

  6. Simulation of speckle patterns with pre-defined correlation distributions

    Science.gov (United States)

    Song, Lipei; Zhou, Zhen; Wang, Xueyan; Zhao, Xing; Elson, Daniel S.

    2016-01-01

    We put forward a method to easily generate a single or a sequence of fully developed speckle patterns with pre-defined correlation distribution by utilizing the principle of coherent imaging. The few-to-one mapping between the input correlation matrix and the correlation distribution between simulated speckle patterns is realized and there is a simple square relationship between the values of these two correlation coefficient sets. This method is demonstrated both theoretically and experimentally. The square relationship enables easy conversion from any desired correlation distribution. Since the input correlation distribution can be defined by a digital matrix or a gray-scale image acquired experimentally, this method provides a convenient way to simulate real speckle-related experiments and to evaluate data processing techniques. PMID:27231589

  7. Static speckle experiments using white synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Sant, Tushar; Panzner, Tobias; Pietsch, Ullrich [Solid State Physics Group, University of Siegen (Germany)

    2008-07-01

    Static speckle experiments were performed using coherent white X-ray radiation from a bending magnet at BESSYII. Semiconductor and polymer surfaces were investigated under incidence condition smaller than the critical angle of total external reflection. The scattering pattern of the sample results from the illumination function modified by the surface undulations. The periodic oscillations are caused by the illumination function whereas other irregular features are associated with sample surface. The speckle map of reflection from a laterally periodic structure like GaAs grating is studied. Under coherent illumination the grating peaks split into speckles because of fluctuations on the sample surface. It is important to understand which length scales on the sample surface are responsible for the oscillations in reflectivity map. To investigate this experiments are done with a triangular shaped sample. Different parts of the sample are illuminated with the footprint on the sample larger or smaller than the actual sample length. This gives prior information about total illuminated area on the sample. Using this additional information a detailed surface profile of the sample is reconstructed.

  8. Echocardiographic Evaluation of Tricuspid Prosthetic Valves: An Update

    Directory of Open Access Journals (Sweden)

    Dimitrios Maragiannis, MD, FASE, FACC

    2016-05-01

    Full Text Available This review focuses on the diagnostic value of novel echocardiographic techniques and the clinical application of recently described algorithms to assess tricuspid prosthetic valve function.

  9. Speckles generated by skewed, short-coherence light beams

    International Nuclear Information System (INIS)

    Brogioli, D; Salerno, D; Ziano, R; Mantegazza, F; Croccolo, F

    2011-01-01

    When a coherent laser beam impinges on a random sample (e.g. a colloidal suspension), the scattered light exhibits characteristic speckles. If the temporal coherence of the light source is too short, then the speckles disappear, along with the possibility of performing homodyne or heterodyne scattering detection or photon correlation spectroscopy. Here we investigate the scattering of a so-called ‘skewed coherence beam’, i.e. a short-coherence beam modified such that the field is coherent within slabs that are skewed with respect to the wave fronts. We show that such a beam generates speckles and can be used for heterodyne scattering detection, despite its short temporal coherence. Moreover, we show that the heterodyne signal is not affected by multiple scattering. We suggest that the phenomenon presented here can be used as a means of carrying out heterodyne scattering measurement with any short-coherence radiation, including x-rays. (paper)

  10. Ergotamine-derived dopamine agonists and left ventricular function in Parkinson patients: systolic and diastolic function studied by conventional echocardiography, tissue Doppler imaging, and two-dimensional speckle tracking.

    Science.gov (United States)

    Rasmussen, Vibeke Guldbrand; Poulsen, Steen Hvitfeldt; Dupont, Erik; Ostergaard, Karen; Safikhany, Gholamhossein; Egeblad, Henrik

    2008-11-01

    Ergot-derived dopamine agonists (EDDA) induce fibrotic heart valve disease. We aimed to investigate whether EDDA treatment also affects left ventricular (LV) function. Myocardial function was evaluated in 110 Parkinson patients [mean age (63.4 +/- 9.0 years)] treated for at least 6 months with either EDDA (n = 71) or non-EDDA (n = 39). LV ejection fraction did not differ between EDDA and non-EDDA patients [63 +/- 4% vs. 65 +/- 4% (ns)]. There was no difference in prevalence of diastolic dysfunction between EDDA and non-EDDA patients [7% vs. 8% (ns)]. Finally, averaged LV systolic myocardial strain and longitudinal displacement analysed by means of two-dimensional speckle tracking showed no difference between EDDA and non-EDDA patients [strain: 19 +/- 3% vs. 19 +/- 2% (ns) and longitudinal displacement: 12 +/- 2 mm vs. 12 +/- 2 mm (ns)]. Elevated p-NT-proBNP was found in 38% of EDDA patients and in 59% of non-EDDA patients (ns). In contrast to the well-established association between EDDA treatment and valvular fibrosis, EDDA did not have a detectable adverse impact on myocardial systolic and diastolic function.

  11. Three-dimensional displacement measurement by fringe projection and speckle photography

    International Nuclear Information System (INIS)

    Barrientos, B.; Garcia-Marquez, J.; Cerca, M.; Hernandez-Bernal, C.

    2008-01-01

    3D displacement fields are measured by the combination of two optical methods, fringe projection and speckle photography. The use of only one camera recording the necessary information implies that no calibration procedures are necessary as is the case in techniques based on stereoscopy. The out-of-plane displacement is measured by fringe projection whereas speckle photography yields the 2-D in-plane component. To show the feasibility of the technique, we analyze a detailed morphological spatio-temporal evolution of a model of the Earth's crust while subjected to compression forces. The results show that the combination of fringe projection and speckle photography is well suited for this type of studies

  12. Review of speckle observations of Supernova 1987A

    International Nuclear Information System (INIS)

    Meikle, W.P.S.

    1988-01-01

    SN 1987A is sufficiently close to allow a unique examination of the morphology of a supernova, using speckle interferometry. Several groups [Center for Astrophysics (CfA); Imperial College (IC); Mount Stromlo and Siding Spring Observatories/Anglo-Australian Observatory (M/A)] have reported optical speckle observations. At Hα, both CfA and M/A have determined the angular extent of the emission, and reasonable agreement is obtained. The speckle-derived values are consistent with those obtained from line profiles. IC has also succeeded in resolving the supernova at Hα. At wavelengths other than Hα, at early epochs, angular diameters obtained by CfA are larger than those derived from photometric and spectroscopic measurements, possibly due to scattering effects. At later epochs, the diameters exhibit little variation between the wavelengths examined. CfA reports significant asymmetry in the late epoch data. Several attempts have been made to re-observe (at optical wavelengths) the companion object, but none have succeeded. The nature of this phenomenon is still controversial, but the evidence indicates that the companion was real, with emission from dust apparently being the least problematic explanation. Support for this may lie in IR speckle observations (Haute Provence/Lyon) which, on about day 115, indicated the presence of one or more resolved components at an angular displacement comparable to that of the optical companion. 39 refs., 1 fig., 1 tab

  13. Does global longitudinal speckle-tracking strain predict left ventricular remodeling in patients with myocardial infarction? a systematic review

    Directory of Open Access Journals (Sweden)

    Afsoon Fazlinejad

    2016-07-01

    Full Text Available Introduction: Left ventricular remodeling is a relatively prevalent complication of acute myocardial infarction (AMI, and it is associated with higher rates of medical issues and mortality. Left ventricle ejection fraction (LVEF and wall motion score index (WMSI are unable to detect accurately minor lesions following AMI. Global longitudinal strain (GLS, which is obtained through 2D-speckle tracking echocardiography (2D-STE, provides an angle-dependent measurement by which the infarcted area can be assessed as a means of identifying potential dysfunction. The main objective of this study was to evaluate whether GLS could adequately predict LV remodeling in AMI patients. Methods: The MEDLINE database from database inception to May 6th, 2015, was searched for relevant keywords and the reference lists of systematic reviews and eligible studies were also screened. All studies involving patients with their first reported case of AMI were examined for GLS by 2D-STE and were evaluated for LV remodeling at a three-month follow-up point.  Four English-language prospective cohort studies were eligible for inclusion in this study.Result: A total of 291 AMI patients (mean age=57.92 years were investigated across four different studies. The main finding of this study was that the most reliable and consistent measurement for the purposes of predicting LV remodeling in AMI patients is GLS obtained at the time of discharge, especially in STEMI patients.Discussion: In addition to their poor reproducibility, inability to stratify risks, and inter-observer variability, compensatory hyperkinesis of intact myocytes and myocardial stunning after an AMI are among the main reasons why LVEF and WMSI may not be the most effective predictors of LV remodeling in AMI.Conclusion: GLS obtained by 2D-STE at the time of discharge could be used as a reliable predictor of LV remodeling in AMI patients.

  14. Speckle imaging using the principle value decomposition method

    International Nuclear Information System (INIS)

    Sherman, J.W.

    1978-01-01

    Obtaining diffraction-limited images in the presence of atmospheric turbulence is a topic of current interest. Two types of approaches have evolved: real-time correction and speckle imaging. A speckle imaging reconstruction method was developed by use of an ''optimal'' filtering approach. This method is based on a nonlinear integral equation which is solved by principle value decomposition. The method was implemented on a CDC 7600 for study. The restoration algorithm is discussed and its performance is illustrated. 7 figures

  15. The importance of speckle tracking echocardiography in the early detection of left ventricular dysfunction in patients with polycystic ovary syndrome

    Directory of Open Access Journals (Sweden)

    Selami Demirelli

    2015-10-01

    Full Text Available Polycystic ovary syndrome (PCOS is characterized by hormonal and metabolic abnormalities and is thought to increase a risk for cardiovascular diseases. In this study we use speckle tracking echocardiography (STE to evaluate left ventricular (LV dysfunction in the early period of the disease. We enrolled 31 patients with PCOS and 32 healthy volunteers as a control group. The participants’ ages ranged between 18 and 40 years. PCOS was diagnosed according to the Rotterdam criteria. LV strain (LS and strain rate (SR were evaluated using apical two-chamber (2C, three-chamber (3C, and four-chamber (4C imaging. Global LS and SR were calculated as average of three apical views. The waist-to-hip ratio, homeostasis model assessment-insulin resistance (HOMA-IR, and fasting insulin and triglyceride levels were higher in the PCOS group than in the controls (p = 0.001, p = 0.001, p = 0.001, and p = 0.005, respectively. In the PCOS group, the mitral A wave, deceleration time (DT, and isovolumetric relaxation time (IVRT were significantly higher than in the controls (all p< 0.05. The LV global longitudinal strain (GLS and global longitudinal SR systolic (GLSRS were significantly lower in the PCOS patient group (both p = 0.001. There were strong negative correlations between GLS and both fasting insulin (r = −0.64 and DT (r = –0.62 (both p < 0.05. The study demonstrated that PCOS patients had decreased LV function using STE. Therefore, STE imaging appears to be useful for the early detection of subclinical LV dysfunction in patients with PCOS.

  16. A comparison between brachial and echocardiographic systolic time intervals.

    Directory of Open Access Journals (Sweden)

    Ho-Ming Su

    Full Text Available Systolic time interval (STI is an established noninvasive technique for the assessment of cardiac function. Brachial STIs can be automatically determined by an ankle-brachial index (ABI-form device. The aims of this study are to evaluate whether the STIs measured from ABI-form device can represent those measured from echocardiography and to compare the diagnostic values of brachial and echocardiographic STIs in the prediction of left ventricular ejection fraction (LVEF <50%. A total of 849 patients were included in the study. Brachial pre-ejection period (bPEP and brachial ejection time (bET were measured using an ABI-form device and pre-ejection period (PEP and ejection time (ET were measured from echocardiography. Agreement was assessed by correlation coefficient and Bland-Altman plot. Brachial STIs had a significant correlation with echocardiographic STIs (r = 0.644, P<0.001 for bPEP and PEP; r  = 0.850, P<0.001 for bET and ET; r = 0.708, P<0.001 for bPEP/bET and PEP/ET. The disagreement between brachial and echocardiographic STIs (brachial STIs minus echocardiographic STIs was 28.55 ms for bPEP and PEP, -4.15 ms for bET and ET and -0.11 for bPEP/bET and PEP/ET. The areas under the curve for bPEP/bET and PEP/ET in the prediction of LVEF <50% were 0.771 and 0.765, respectively. Brachial STIs were good alternatives to STIs obtained from echocardiography and also helpful in prediction of LVEF <50%. Brachial STIs automatically obtained from an ABI-form device may be helpful for evaluation of left ventricular systolic dysfunction.

  17. Analysis of statistical properties of laser speckles, forming in skin and mucous of colon: potential application in laser surgery

    Science.gov (United States)

    Rubtsov, Vladimir; Kapralov, Sergey; Chalyk, Iuri; Ulianova, Onega; Ulyanov, Sergey

    2013-02-01

    Statistical properties of laser speckles, formed in skin and mucous of colon have been analyzed and compared. It has been demonstrated that first and second order statistics of "skin" speckles and "mucous" speckles are quite different. It is shown that speckles, formed in mucous, are not Gaussian one. Layered structure of colon mucous causes formation of speckled biospeckles. First- and second- order statistics of speckled speckles have been reviewed in this paper. Statistical properties of Fresnel and Fraunhofer doubly scattered and cascade speckles are described. Non-gaussian statistics of biospeckles may lead to high localization of intensity of coherent light in human tissue during the laser surgery. Way of suppression of highly localized non-gaussian speckles is suggested.

  18. Common echocardiographic abnormalities in Nigerians of different ...

    African Journals Online (AJOL)

    2012-09-17

    Sep 17, 2012 ... artery disease, cardiac murmurs, atrial fibrillation, stroke, and transient ischaemic attack.[4,5] In some circumstances, the examination is an appropriate screening test even in the absence of cardiovascular symptoms, especially. Common echocardiographic abnormalities in. Nigerians of different age groups.

  19. Echocardiographic Assessment of Heart Valve Prostheses

    Science.gov (United States)

    Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio

    2014-01-01

    Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917

  20. Vegetation Detection in Stress of Moisture Shortage Based on Laser Speckle Recognition

    Science.gov (United States)

    Ishizawa, Hiroaki; Matsuo, Tsukasa; Miki, Takashi

    This paper describes a new measuring method of plant vigor by using Laser speckle pattern. Furthermore, this proposes a practical application of this presented measurement system. The measuring instrument is consisted by a He-Ne Laser as the light source, and a set of optics, such as reflectors, a beam expander. The speckle pattern could be measured by a CCD camera through lenses. A Pothos (Epiremnum aureum) and Japanese morning glory (Ipomoea nil) were used as the sample plant. Their intact leaves were measured the speckle pattern images. Visible but small vigor veins could be clearly observed in the images obtained by the speckle patterns. On the other hand, withered ones have shown different images. The relationship has been obtained between the feature of the images and the chlorophyll degradation. It would be expected that the symptom of plant against some stress could be detected by measuring the Laser speckle pattern. It could be used as the sensor of the field server system at every field monitoring site.

  1. Speckle Interferometry with the OCA Kuhn 22" Telescope

    Science.gov (United States)

    Wasson, Rick

    2018-04-01

    Speckle interferometry measurements of double stars were made in 2015 and 2016, using the Kuhn 22-inch classical Cassegrain telescope of the Orange County Astronomers, a Point Grey Blackfly CMOS camera, and three interference filters. 272 observations are reported for 177 systems, with separations ranging from 0.29" to 2.9". Data reduction was by means of the REDUC and Speckle Tool Box programs. Equipment, observing procedures, calibration, data reduction, and analysis are described, and unusual results for 11 stars are discussed in detail.

  2. Correcting for motion artifact in handheld laser speckle images

    Science.gov (United States)

    Lertsakdadet, Ben; Yang, Bruce Y.; Dunn, Cody E.; Ponticorvo, Adrien; Crouzet, Christian; Bernal, Nicole; Durkin, Anthony J.; Choi, Bernard

    2018-03-01

    Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.

  3. Dynamic laser speckle for non-destructive quality evaluation of bread

    Science.gov (United States)

    Stoykova, E.; Ivanov, B.; Shopova, M.; Lyubenova, T.; Panchev, I.; Sainov, V.

    2010-10-01

    Coherent illumination of a diffuse object yields a randomly varying interference pattern, which changes over time at any modification of the object. This phenomenon can be used for detection and visualization of physical or biological activity in various objects (e.g. fruits, seeds, coatings) through statistical description of laser speckle dynamics. The present report aims at non-destructive full-field evaluation of bread by spatial-temporal characterization of laser speckle. The main purpose of the conducted experiments was to prove the ability of the dynamic speckle method to indicate activity within the studied bread samples. In the set-up for acquisition and storage of dynamic speckle patterns an expanded beam from a DPSS laser (532 nm and 100mW) illuminated the sample through a ground glass diffuser. A CCD camera, adjusted to focus the sample, recorded regularly a sequence of images (8 bits and 780 x 582 squared pixels, sized 8.1 × 8.1 μm) at sampling frequency 0.25 Hz. A temporal structure function was calculated to evaluate activity of the bread samples in time using the full images in the sequence. In total, 7 samples of two types of bread were monitored during a chemical and physical process of bread's staling. Segmentation of images into matrixes of isometric fragments was also utilized. The results proved the potential of dynamic speckle as effective means for monitoring the process of bread staling and ability of this approach to differentiate between different types of bread.

  4. Spiking cortical model-based nonlocal means method for speckle reduction in optical coherence tomography images

    Science.gov (United States)

    Zhang, Xuming; Li, Liu; Zhu, Fei; Hou, Wenguang; Chen, Xinjian

    2014-06-01

    Optical coherence tomography (OCT) images are usually degraded by significant speckle noise, which will strongly hamper their quantitative analysis. However, speckle noise reduction in OCT images is particularly challenging because of the difficulty in differentiating between noise and the information components of the speckle pattern. To address this problem, the spiking cortical model (SCM)-based nonlocal means method is presented. The proposed method explores self-similarities of OCT images based on rotation-invariant features of image patches extracted by SCM and then restores the speckled images by averaging the similar patches. This method can provide sufficient speckle reduction while preserving image details very well due to its effectiveness in finding reliable similar patches under high speckle noise contamination. When applied to the retinal OCT image, this method provides signal-to-noise ratio improvements of >16 dB with a small 5.4% loss of similarity.

  5. M2 FILTER FOR SPECKLE NOISE SUPPRESSION IN BREAST ULTRASOUND IMAGES

    Directory of Open Access Journals (Sweden)

    E.S. Samundeeswari

    2016-11-01

    Full Text Available Breast cancer, commonly found in women is a serious life threatening disease due to its invasive nature. Ultrasound (US imaging method plays an effective role in screening early detection and diagnosis of Breast cancer. Speckle noise generally affects medical ultrasound images and also causes a number of difficulties in identifying the Region of Interest. Suppressing speckle noise is a challenging task as it destroys fine edge details. No specific filter is designed yet to get a noise free BUS image that is contaminated by speckle noise. In this paper M2 filter, a novel hybrid of linear and nonlinear filter is proposed and compared to other spatial filters with 3×3 kernel size. The performance of the proposed M2 filter is measured by statistical quantity parameters like MSE, PSNR and SSI. The experimental analysis clearly shows that the proposed M2 filter outperforms better than other spatial filters by 2% high PSNR values with regards to speckle suppression.

  6. Spatially resolved speckle-correlometry of sol-gel transition

    Science.gov (United States)

    Isaeva, A. A.; Isaeva, E. A.; Pantyukov, A. V.; Zimnyakov, D. A.

    2018-04-01

    Sol-gel transition was studied using the speckle correlometry method with a localized light source and spatial filtering of backscattered radiation. Water solutions of technical or food gelatin with added TiO2 nanoparticles were used as studied objects. Structural transformation of "sol-gel" system was studied at various temperatures from 25°C to 50°C using analysis of the correlation and structure functions of speckle intensity fluctuations. The characteristic temperatures of "sol - gel" transition were evaluated for studied systems. Obtained results can be used for various applications in biomedicine and food industry.

  7. Role of Echocardiography in the Management and Prognosis of Atrial Fibrillation

    Science.gov (United States)

    Silverman, David I; Ayirala, Srilatha R; Manning, Warren J

    2012-01-01

    Echocardiography plays a longstanding and vital role in the management of atrial fibrillation (AF). Advances in 2D imaging, Doppler echocardiography and strain imaging have all contributed to major progress in AF treatment. Echocardiographically measured left atrial (LA) volume is a powerful predictor of maintenance of sinus rhythm following cardioversion as well as risk of thrombus formation and thromboembolism. Doppler derived parameters of atrial mechanical function including atrial ejection force provide related prognostic information. Transesophageal echocardiocardiograpy (TEE) guided cardioversion of AF allows for rapid conversion to sinus rhythm without prolonged oral anticoagulation, and TEE serves as a useful tool during catheter ablation of AF and atrial flutter. Newer measures derived from speckle tracking offer great promise in further improving the care of patients with AF. PMID:28496715

  8. Echocardiographic evaluation of pre-diagnostic development in young relatives genetically predisposed to hypertrophic cardiomyopathy

    DEFF Research Database (Denmark)

    Jensen, Morten K; Havndrup, Ole; Christiansen, Michael

    2015-01-01

    Identification of the first echocardiographic manifestations of hypertrophic cardiomyopathy may be important for clinical management and our understanding of the pathogenesis. We studied the development of pre-diagnostic echocardiographic changes in young relatives to HCM patients during long...... of relatives with unknown genetic status. Children carrying pathogenic sarcomere gene mutations develop reduced LVEDd and increased E/e' as first pre-diagnostic echocardiographic manifestations during follow-up into adulthood.......-term years follow-up. HCM-relatives not fulfilling the diagnostic criteria for HCM and age of family screening of 11 sarcomere genes, CRYAB, α-GAL, and titin, we evaluated...

  9. New developments in NDT through electronic speckle pattern interferometry

    International Nuclear Information System (INIS)

    Mohan, S.; Murugesan, P; Mas, R.H.

    2007-01-01

    Full text: Optical holography and speckle interferometry are the emerging optical techniques that can be used for the measurements of microscopic parameters such as displacement, strain, stress and slope. These techniques are applied in various fields such as surface studies, non destructive testing, speckle metrology and steller interferometry. Even though many new NDT methods are available, the suitability for a specific application is based on the material property, nature of defects and sensitivity of detection. Difficulty in radiographic technique is that it fails in detecting tight cracks, planar defects and debonds. Microwave techniques has limited sensitivity for the defect detection and it is not suitable for the objects with metallic cases since the metals are perfect reflectors for the microwaves. Low modulus material attenuates the acoustic energy completely, making ultrasonic testing techniques not feasible. The recently evolved optoelectronic technique namely Electronic Speckle Pattern interferometry (ESPI) is a fast developing optical technique widely used for measuring displacement components, their derivatives, surface roughness, surface contours, shape and others. Due to non contact nature and high sensitivity, this technique has been used as a powerful on line inspection tool for non destructive pattern of materials in industrial environment. The salient feature of ESPI is its capability to display the correlation fringes in a real time on a monitor without the need of photographic processing or optical filtering. ESPI is an alternate non destructive technique suitable for propellant grains and other low modulus materials used in space vehicle systems. The optoelectronic technique can be used to detect cracks, voids and residual stresses etc.., in the components in the industrial environment. In the present investigation, speckle non destructive testing has been carried out on some selected low modulus materials used in space vehicles. The

  10. Compensation for the signal processing characteristics of ultrasound B-mode scanners in adaptive speckle reduction.

    Science.gov (United States)

    Crawford, D C; Bell, D S; Bamber, J C

    1993-01-01

    A systematic method to compensate for nonlinear amplification of individual ultrasound B-scanners has been investigated in order to optimise performance of an adaptive speckle reduction (ASR) filter for a wide range of clinical ultrasonic imaging equipment. Three potential methods have been investigated: (1) a method involving an appropriate selection of the speckle recognition feature was successful when the scanner signal processing executes simple logarithmic compressions; (2) an inverse transform (decompression) of the B-mode image was effective in correcting for the measured characteristics of image data compression when the algorithm was implemented in full floating point arithmetic; (3) characterising the behaviour of the statistical speckle recognition feature under conditions of speckle noise was found to be the method of choice for implementation of the adaptive speckle reduction algorithm in limited precision integer arithmetic. In this example, the statistical features of variance and mean were investigated. The third method may be implemented on commercially available fast image processing hardware and is also better suited for transfer into dedicated hardware to facilitate real-time adaptive speckle reduction. A systematic method is described for obtaining ASR calibration data from B-mode images of a speckle producing phantom.

  11. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  12. A Portable Dynamic Laser Speckle System for Sensing Long-Term Changes Caused by Treatments in Painting Conservation.

    Science.gov (United States)

    Pérez, Alberto J; González-Peña, Rolando J; Braga, Roberto; Perles, Ángel; Pérez-Marín, Eva; García-Diego, Fernando J

    2018-01-11

    Dynamic laser speckle (DLS) is used as a reliable sensor of activity for all types of materials. Traditional applications are based on high-rate captures (usually greater than 10 frames-per-second, fps). Even for drying processes in conservation treatments, where there is a high level of activity in the first moments after the application and slower activity after some minutes or hours, the process is based on the acquisition of images at a time rate that is the same in moments of high and low activity. In this work, we present an alternative approach to track the drying process of protective layers and other painting conservation processes that take a long time to reduce their levels of activity. We illuminate, using three different wavelength lasers, a temporary protector (cyclododecane) and a varnish, and monitor them using a low fps rate during long-term drying. The results are compared to the traditional method. This work also presents a monitoring method that uses portable equipment. The results present the feasibility of using the portable device and show the improved sensitivity of the dynamic laser speckle when sensing the long-term process for drying cyclododecane and varnish in conservation.

  13. A Portable Dynamic Laser Speckle System for Sensing Long-Term Changes Caused by Treatments in Painting Conservation

    Science.gov (United States)

    Pérez, Alberto J.; Braga, Roberto; Perles, Ángel; Pérez–Marín, Eva; García-Diego, Fernando J.

    2018-01-01

    Dynamic laser speckle (DLS) is used as a reliable sensor of activity for all types of materials. Traditional applications are based on high-rate captures (usually greater than 10 frames-per-second, fps). Even for drying processes in conservation treatments, where there is a high level of activity in the first moments after the application and slower activity after some minutes or hours, the process is based on the acquisition of images at a time rate that is the same in moments of high and low activity. In this work, we present an alternative approach to track the drying process of protective layers and other painting conservation processes that take a long time to reduce their levels of activity. We illuminate, using three different wavelength lasers, a temporary protector (cyclododecane) and a varnish, and monitor them using a low fps rate during long-term drying. The results are compared to the traditional method. This work also presents a monitoring method that uses portable equipment. The results present the feasibility of using the portable device and show the improved sensitivity of the dynamic laser speckle when sensing the long-term process for drying cyclododecane and varnish in conservation. PMID:29324692

  14. Laser speckle imaging: a novel method for detecting dental erosion.

    Directory of Open Access Journals (Sweden)

    Nelson H Koshoji

    Full Text Available Erosion is a highly prevalent condition known as a non-carious lesion that causes progressive tooth wear due to chemical processes that do not involve the action of bacteria. Speckle images proved sensitive to even minimal mineral loss from the enamel. The aim of the present study was to investigate the use of laser speckle imaging analysis in the spatial domain to quantify shifts in the microstructure of the tooth surface in an erosion model. 32 fragments of the vestibular surface of bovine incisors were divided in for groups (10 min, 20 min. 30 min and 40 min of acid etching immersed in a cola-based beverage (pH approximately 2.5 twice a day during 7 days to create an artificial erosion. By analyzing the laser speckle contrast map (LASCA in the eroded region compared to the sound it was observed that the LASCA map shifts, proportionally to the acid each duration, by: 18%; 23%; 39% and 44% for the 10 min; 20 min; 30 min and 40 min groups, respectively. To the best of our knowledge, this is the first study to demonstrate the correlation between speckle patterns and erosion progression.

  15. Electronic speckle pattern interferometry observation of brick–mortar interface behaviour under compression

    NARCIS (Netherlands)

    Vermeltfoort, A.T.; Martens, D.R.W; Zijl, van G.P.A.G.

    2007-01-01

    The brick–mortar interaction is important in the mechanical behaviour of masonry. It affects the load transfer considerably, as shown by detailed deformation measurements taken using electronic speckle pattern interferometry (ESPI), a laser speckle interference technique. A companion paper [Canadian

  16. Edge Probability and Pixel Relativity-Based Speckle Reducing Anisotropic Diffusion.

    Science.gov (United States)

    Mishra, Deepak; Chaudhury, Santanu; Sarkar, Mukul; Soin, Arvinder Singh; Sharma, Vivek

    2018-02-01

    Anisotropic diffusion filters are one of the best choices for speckle reduction in the ultrasound images. These filters control the diffusion flux flow using local image statistics and provide the desired speckle suppression. However, inefficient use of edge characteristics results in either oversmooth image or an image containing misinterpreted spurious edges. As a result, the diagnostic quality of the images becomes a concern. To alleviate such problems, a novel anisotropic diffusion-based speckle reducing filter is proposed in this paper. A probability density function of the edges along with pixel relativity information is used to control the diffusion flux flow. The probability density function helps in removing the spurious edges and the pixel relativity reduces the oversmoothing effects. Furthermore, the filtering is performed in superpixel domain to reduce the execution time, wherein a minimum of 15% of the total number of image pixels can be used. For performance evaluation, 31 frames of three synthetic images and 40 real ultrasound images are used. In most of the experiments, the proposed filter shows a better performance as compared to the state-of-the-art filters in terms of the speckle region's signal-to-noise ratio and mean square error. It also shows a comparative performance for figure of merit and structural similarity measure index. Furthermore, in the subjective evaluation, performed by the expert radiologists, the proposed filter's outputs are preferred for the improved contrast and sharpness of the object boundaries. Hence, the proposed filtering framework is suitable to reduce the unwanted speckle and improve the quality of the ultrasound images.

  17. Shift-Invariant Image Reconstruction of Speckle-Degraded Images Using Bispectrum Estimation

    Science.gov (United States)

    1990-05-01

    process with the requisite negative exponential pelf. I call this model the Negative Exponential Model ( NENI ). The NENI flowchart is seen in Figure 6...Figure ]3d-g. Statistical Histograms and Phase for the RPj NG EXP FDF MULT METHOD FILuteC 14a. Truth Object Speckled Via the NENI HISTOGRAM OF SPECKLE

  18. Evaluation of Left Ventricular Diastolic Dysfunction with Early Systolic Dysfunction Using Two-Dimensional Speckle Tracking Echocardiography in Canine Heart Failure Model.

    Science.gov (United States)

    Wu, Wei-Chun; Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Tang, Yue; Wang, Hao

    2016-04-01

    This study evaluated the role of two-dimensional speckle tracking echocardiography (2DSTE) for predicting left ventricular (LV) diastolic dysfunction in pacing-induced canine heart failure. Pacing systems were implanted in 8 adult mongrel dogs, and continuous rapid right ventricular pacing (RVP, 240 beats/min) was maintained for 2 weeks. The obtained measurements from 2DSTE included global strain rate during early diastole (SRe) and during late diastole (SRa) in the longitudinal (L-SRe, L-SRa), circumferential (C-SRe, C-SRa), and radial directions (R-SRe, R-SRa). Changes in heart morphology were observed by light microscopy and transmission electron microscopy at 2 weeks. The onset of LV diastolic dysfunction with early systolic dysfunction occurred 3 days after RVP initiation. Most of the strain rate imaging indices were altered at 1 or 3 days after RVP onset and continued to worsen until heart failure developed. Light and transmission electron microscopy showed myocardial vacuolar degeneration and mitochondrial swelling in the left ventricular at 2 weeks after RVP onset. Pearson's correlation analysis revealed that parameters of conventional echocardiography and 2DSTE showed moderate correlation with LV pressure parameters, including E/Esep' (r = 0.58, P echocardiography and strain rate imaging could effectively predict LV diastolic dysfunction (area under the curve: E/Esep' 0.78; L-SRe 0.84; E/L-SRe 0.80; R-SRe 0.80). 2DSTE was a sensitive and accurate technique that could be used for predicting LV diastolic dysfunction in canine heart failure model. © 2015, Wiley Periodicals, Inc.

  19. Granulometry use for the study of dynamics speckles patterns

    International Nuclear Information System (INIS)

    Mavilioa, Adriana; Fernandez, Margarita; Trivi, Marcelo; Rabal, Hector; Arizaga, Ricardo

    2009-01-01

    Dynamic speckle patterns are generated by laser light scattering on surfaces that exhibit some kind of activity, due to physical or biological processes that take place in the illuminated object. The characterization of this dynamic process is carried out by studying the texture changes of auxiliary images: temporal history of the speckle pattern (THSP) obtained from this speckles patterns. The drying process of water borne paint is studied through a method based on mathematical morphology applied to the THSP image processing. It is based on obtaining the granulometry of these images and their characteristic granulometric spectrum. From the granulometric size distribution of each THSP image four parameters are obtained: mean length, standard deviation, asymmetry and kurtosis. These parameters are found to be suitable as texture features. The Mahalanobis distance is calculated between the texture features of the THSP images representative of the temporary stages of the drying process and the features of the final stage or pattern texture. The behavior of the distance function describes satisfactorily the drying process of the water borne paint. Finally, these results are compared with the obtained by other methods. Compared with others, the granulometric method reported in this work distinguished by its simplicity and easy implementation and can be used to characterize the evolution of any process recorded through dynamic speckles. (Author)

  20. Two-dimensional echocardiographic features of right ventricular infarction

    International Nuclear Information System (INIS)

    D'Arcy, B.; Nanda, N.C.

    1982-01-01

    Real-time, two-dimensional echocardiographic studies were performed in 10 patients with acute myocardial infarction who had clinical features suggestive of right ventricular involvement. All patients showed right ventricular wall motion abnormalities. In the four-chamber view, seven patients showed akinesis of the entire right ventricular diaphragmatic wall and three showed akinesis of segments of the diaphragmatic wall. Segmental dyskinetic areas involving the right ventricular free wall were identified in four patients. One patient showed a large right ventricular apical aneurysm. Other echocardiographic features included enlargement of the right ventricle in eight cases, paradoxical ventricular septal motion in seven cases, tricuspid incompetence in eight cases, dilation of the stomach in four cases and localized pericardial effusion in two cases. Right ventricular infarction was confirmed by radionuclide methods in seven patients, at surgery in one patient and at autopsy in two patients

  1. Clinical and echocardiographic features of aorto-atrial fistulas

    Directory of Open Access Journals (Sweden)

    Ananthasubramaniam Karthik

    2005-01-01

    Full Text Available Abstract Aorto-atrial fistulas (AAF are rare but important pathophysiologic conditions of the aorta and have varied presentations such as acute pulmonary edema, chronic heart failure and incidental detection of the fistula. A variety of mechanisms such as aortic dissection, endocarditis with pseudoaneurysm formation, post surgical scenarios or trauma may precipitate the fistula formation. With increasing survival of patients, particularly following complex aortic reconstructive surgeries and redo valve surgeries, recognition of this complication, its clinical features and echocardiographic diagnosis is important. Since physical exam in this condition may be misleading, echocardiography serves as the cornerstone for diagnosis. The case below illustrates aorto-left atrial fistula formation following redo aortic valve surgery with slowly progressive symptoms of heart failure. A brief review of the existing literature of this entity is presented including emphasis on echocardiographic diagnosis and treatment.

  2. Ia diastolic dysfunction: an echocardiographic grade.

    Science.gov (United States)

    Pandit, Anil; Mookadam, Farouk; Hakim, Fayaz A; Mulroy, Eoin; Saadiq, Rayya; Doherty, Mairead; Cha, Stephen; Seward, James; Wilansky, Susan

    2015-01-01

    To demonstrate that a distinct group of patients with Grade Ia diastolic dysfunction who do not conform to present ASE/ESE diastolic grading exists. Echocardiographic and demographic data of the Grade Ia diastolic dysfunction were extracted and compared with that of Grades I and II in 515 patients. The mean of age of the cohort was 75 ± 9 years and body mass index did not differ significantly between the 3 groups (P = 0.45). Measurements of left atrial volume index (28.58 ± 7 mL/m(2) in I, 33 ± 10 mL/m(2) in Ia, and 39 ± 12 mL/m(2) in II P Ia, and 79 ± 15 msec in II P Ia, and 217 ± 57 msec in II P Ia, and 22 ± 8 in II), and lateral E/e' (8 ± 3 in I, 15 ± 6 in Ia, and 18 ± 9 in II P Ia compared with I and II. These findings remained significant even after adjusting for age, gender, diabetes, and smoking. Patients with echocardiographic characteristics of relaxation abnormality (E/A ratio of Ia group. © 2014, Wiley Periodicals, Inc.

  3. Enhanced Right-Chamber Remodeling in Endurance Ultra-Trail Athletes Compared to Marathon Runners Detected by Standard and Speckle-Tracking Echocardiography

    Directory of Open Access Journals (Sweden)

    Kristian Ujka

    2017-07-01

    Full Text Available Background: Strenuous and endurance exercise training have been associated with morphological and functional heart remodeling. Two-dimensional speckle-tracking echocardiography (STE is a novel technique that allows an accurate quantification of global myocardium deformation. Our aim was to evaluate together left and right cardiac remodeling in different long-distance running athletes: marathon runners (42 km (M and endurance mountain runners (>300 Km (UT.Methods: A total of 92 athletes (70 males, 76% including 47 M [age 45 ± 7 years; training: 18 (9–53 years*days/week], 45 UT [age 42 ± 9, training: 30 (15–66 years*days/week] underwent conventional echocardiography and STE (Beyond Diogenes 2.0, AMID during the agonistic season.Results: Right ventricle (RV end-diastolic area (p = 0.026, fractional area changing (FAC (p = 0.008 and RV global longitudinal strain (GLS were significantly increasedin UT athletes. Furthermore, UT showed larger right atrium (RA volume (p = 0.03, reduced RA GLS and significantly increased RA global circumferential strain (GCS compared to M. After adjustment for age, sex, and HR as covariates, UT showed a reduced RA GLS (OR 0.907; CI 0.856–0.961 and increased RV FAC (OR 1.172; CI: 1.044–1.317 compared to M.Conclusion: Athletes enrolled in UT endurance activities showed RV and RA morphological and functional remodeling to increased preload in comparison with M runners characterized by increased RV FAC and reduced RA GLS. Follow-up studies are needed to better assess the long-term clinical impact of these modifications. 2D STE is a useful tool for investigating the deformation dynamic in different sports specialties.

  4. Density of states in an optical speckle potential

    International Nuclear Information System (INIS)

    Falco, G. M.; Fedorenko, A. A.; Giacomelli, J.; Modugno, M.

    2010-01-01

    We study the single-particle density of states of a one-dimensional speckle potential, which is correlated and non-Gaussian. We consider both the repulsive and the attractive cases. The system is controlled by a single dimensionless parameter determined by the mass of the particle, the correlation length, and the average intensity of the field. Depending on the value of this parameter, the system exhibits different regimes, characterized by the localization properties of the eigenfunctions. We calculate the corresponding density of states using the statistical properties of the speckle potential. We find good agreement with the results of numerical simulations.

  5. Speckle reduction in optical coherence tomography images based on wave atoms

    Science.gov (United States)

    Du, Yongzhao; Liu, Gangjun; Feng, Guoying; Chen, Zhongping

    2014-01-01

    Abstract. Optical coherence tomography (OCT) is an emerging noninvasive imaging technique, which is based on low-coherence interferometry. OCT images suffer from speckle noise, which reduces image contrast. A shrinkage filter based on wave atoms transform is proposed for speckle reduction in OCT images. Wave atoms transform is a new multiscale geometric analysis tool that offers sparser expansion and better representation for images containing oscillatory patterns and textures than other traditional transforms, such as wavelet and curvelet transforms. Cycle spinning-based technology is introduced to avoid visual artifacts, such as Gibbs-like phenomenon, and to develop a translation invariant wave atoms denoising scheme. The speckle suppression degree in the denoised images is controlled by an adjustable parameter that determines the threshold in the wave atoms domain. The experimental results show that the proposed method can effectively remove the speckle noise and improve the OCT image quality. The signal-to-noise ratio, contrast-to-noise ratio, average equivalent number of looks, and cross-correlation (XCOR) values are obtained, and the results are also compared with the wavelet and curvelet thresholding techniques. PMID:24825507

  6. Camera-based speckle noise reduction for 3-D absolute shape measurements.

    Science.gov (United States)

    Zhang, Hao; Kuschmierz, Robert; Czarske, Jürgen; Fischer, Andreas

    2016-05-30

    Simultaneous position and velocity measurements enable absolute 3-D shape measurements of fast rotating objects for instance for monitoring the cutting process in a lathe. Laser Doppler distance sensors enable simultaneous position and velocity measurements with a single sensor head by evaluating the scattered light signals. The superposition of several speckles with equal Doppler frequency but random phase on the photo detector results in an increased velocity and shape uncertainty, however. In this paper, we present a novel image evaluation method that overcomes the uncertainty limitations due to the speckle effect. For this purpose, the scattered light is detected with a camera instead of single photo detectors. Thus, the Doppler frequency from each speckle can be evaluated separately and the velocity uncertainty decreases with the square root of the number of camera lines. A reduction of the velocity uncertainty by the order of one magnitude is verified by the numerical simulations and experimental results, respectively. As a result, the measurement uncertainty of the absolute shape is not limited by the speckle effect anymore.

  7. Investigation of Portevin-Le Chatelier band with temporal phase analysis of speckle interferometry

    Science.gov (United States)

    Jiang, Zhenyu; Zhang, Qingchuan; Wu, Xiaoping

    2003-04-01

    A new method combining temporal phase analysis with dynamic digital speckle pattern interferometry is proposed to study Portevin-Le Chatelier effect quantitatively. The principle bases on that the phase difference of interference speckle patterns is a time-dependent function related to the object deformation. The interference speckle patterns of specimen are recorded with high sampling rate while PLC effect occurs, and the 2D displacement map of PLC band and its width are obtained by analyzing the displacement of specimen with proposed method.

  8. Analysis of strain in reinforced concrete components by laser speckle photography

    International Nuclear Information System (INIS)

    Gross, K.P.

    1982-01-01

    Laser speckle photography is an optical process for non-contact measurement of strain in a plane at right angles to the axis of the optical system. The material composition and relief of the surface of a test sample have a great effect on the applicability of the process. Bodies with too smooth or too rough surfaces, and bodies of a transparent structure (salt bearing rocks) cannot be examined by speckle photography without previous surface treatment. The principle of the process and its application to the examination of reinforced concrete components is described. The capability of speckle photography, the accuracy of measurement which can be achieved and possible sources of error are discussed. (orig./RW) [de

  9. A New Approach for Speckle Reduction in Holographic 3D printer

    International Nuclear Information System (INIS)

    Utsugi, Takeru; Yamaguchi, Masahiro

    2013-01-01

    A Holographic 3D printer produces a high quality 3D image reproduced by a full-color, full-parallax holographic stereogram with high-density light-ray recording. But speckle-pattern noise localized behind the reconstructed image is causing a loss of the display quality. This noise is originated from the speckle generated by a diffuser for equalizing the intensity distribution of the object light on the recording medium. We analyze some conventional ways for speckle reduction using a band-limited diffuser, and it is found that these ways cannot reduce the noise sufficiently. Then we propose two methods, one introduces a moving diffuser and the other introduces multiple exposures and a digital diffuser called as 4L-PRPS.

  10. Changes in right ventricular function assessed by echocardiography in dog models of mild RV pressure overload.

    Science.gov (United States)

    Morita, Tomoya; Nakamura, Kensuke; Osuga, Tatsuyuki; Yokoyama, Nozomu; Morishita, Keitaro; Sasaki, Noboru; Ohta, Hiroshi; Takiguchi, Mitsuyoshi

    2017-07-01

    The assessment of hemodynamic change by echocardiography is clinically useful in patients with pulmonary hypertension. Recently, mild elevation of the mean pulmonary arterial pressure (PAP) has been shown to be associated with increased mortality. However, changes in the echocardiographic indices of right ventricular (RV) function are still unknown. The objective of this study was to validate the relationship between echocardiographic indices of RV function and right heart catheterization variables under a mild RV pressure overload condition. Echocardiography and right heart catheterization were performed in dog models of mild RV pressure overload induced by thromboxane A 2 analog (U46619) (n=7). The mean PAP was mildly increased (19.3±1.1 mm Hg), and the cardiac index was decreased. Most echocardiographic indices of RV function were significantly impaired even under a mild RV pressure overload condition. Multivariate analysis revealed that the RV free wall longitudinal strain (RVLS), standard deviation of the time-to-peak longitudinal strain of RV six segments (RV-SD) by speckle-tracking echocardiography, and Tei index were independent echocardiographic predictors of the mean PAP (free wall RVLS, β=-0.60, P<.001; RV-SD, β=0.40, P=.011), pulmonary vascular resistance (free wall RVLS, β=-0.39, P=.020; RV-SD, β=0.47, P=.0086; Tei index, β=0.34, P=.047), and cardiac index (Tei index, β=-0.65, P<.001). Free wall RVLS, RV-SD, and Tei index are useful for assessing the hemodynamic change under a mild RV pressure overload condition. © 2017, Wiley Periodicals, Inc.

  11. ARTIFICIAL INCOHERENT SPECKLES ENABLE PRECISION ASTROMETRY AND PHOTOMETRY IN HIGH-CONTRAST IMAGING

    Energy Technology Data Exchange (ETDEWEB)

    Jovanovic, N.; Guyon, O.; Pathak, P.; Kudo, T. [National Astronomical Observatory of Japan, Subaru Telescope, 650 North A’Ohoku Place, Hilo, HI, 96720 (United States); Martinache, F. [Observatoire de la Cote d’Azur, Boulevard de l’Observatoire, F-06304 Nice (France); Hagelberg, J., E-mail: jovanovic.nem@gmail.com [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822 (United States)

    2015-11-10

    State-of-the-art coronagraphs employed on extreme adaptive optics enabled instruments are constantly improving the contrast detection limit for companions at ever-closer separations from the host star. In order to constrain their properties and, ultimately, compositions, it is important to precisely determine orbital parameters and contrasts with respect to the stars they orbit. This can be difficult in the post-coronagraphic image plane, as by definition the central star has been occulted by the coronagraph. We demonstrate the flexibility of utilizing the deformable mirror in the adaptive optics system of the Subaru Coronagraphic Extreme Adaptive Optics system to generate a field of speckles for the purposes of calibration. Speckles can be placed up to 22.5 λ/D from the star, with any position angle, brightness, and abundance required. Most importantly, we show that a fast modulation of the added speckle phase, between 0 and π, during a long science integration renders these speckles effectively incoherent with the underlying halo. We quantitatively show for the first time that this incoherence, in turn, increases the robustness and stability of the adaptive speckles, which will improve the precision of astrometric and photometric calibration procedures. This technique will be valuable for high-contrast imaging observations with imagers and integral field spectrographs alike.

  12. Fabrication of nanoscale speckle using broad ion beam milling on polymers for deformation analysis

    Directory of Open Access Journals (Sweden)

    Qinghua Wang

    2016-07-01

    Full Text Available We first report a fabrication technique of nanoscale speckle patterns on polymers using broad ion beam milling. The proposed technique is simple and low-cost to produce speckles ranging from dozens of nanometers to less than three micrometers in a large area of several millimeters. Random patterns were successfully produced with an argon (Ar ion beam on the surfaces of four kinds of polymers: the epoxy matrix of carbon fiber reinforced plastic, polyester, polyvinyl formal-acetal, and polyimide. The speckle morphologies slightly vary with different polymers. The fabricated speckle patterns have good time stability and are promising to be used to measure the nanoscale deformations of polymers using the digital image correlation method.

  13. Can echocardiographic findings predict falls in older persons?

    NARCIS (Netherlands)

    N. van der Velde (Nathalie); B.H.Ch. Stricker (Bruno); J.R.T.C. Roelandt (Jos); F.J. ten Cate (Folkert); T.J.M. van der Cammen (Tischa)

    2007-01-01

    textabstractBackground. The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. Method and

  14. Reversal of echocardiographic right-sided heart pathology in a dog with severe pulmonary hypertension: a case report

    Directory of Open Access Journals (Sweden)

    McMahon P

    2015-06-01

    Full Text Available Peggy McMahon,1 Carley Saelinger 2  1Emergency and Critical Care Department, 2Cardiology Department, Animal Specialty and Emergency Center, Los Angeles, CA, USA Abstract: Pathologic right-sided heart changes are a common echocardiographic finding in patients with pulmonary hypertension (PH. Canines with PH may have right heart pathology documented via echocardiographic color Doppler interrogation including tricuspid valve regurgitation, pulmonic valve insufficiency, elevated pulmonary arterial systolic pressure, elevated pulmonary arterial diastolic pressure, and alterations in ejection profiles. Two-dimensional echocardiographic findings may include right ventricular hypertrophy, interventricular septal flattening, paradoxical interventricular septal motion, pulmonary artery dilation, and potentially abnormal left heart dimensions. In veterinary medicine, much confidence is given to the measurement of pulmonary arterial systolic pressure estimated from tricuspid valve regurgitation to grade the severity of PH and monitor its improvement with little emphasis placed on the integration of two-dimensional echocardiographic right and left heart pathology in conjunction with Doppler findings. To the authors’ knowledge, marked improvement and/or resolution of echocardiographic-documented right heart pathology have not been previously reported in the veterinary literature. This case report documents profound echocardiographic improvement of right-sided heart disease in a dog with severe PH. Keywords: canine, pulmonary hypertension, tricuspid valve regurgitation, right heart hypertrophy, sildenafil  

  15. NESSI and `Alopeke: Two new dual-channel speckle imaging instruments

    Science.gov (United States)

    Scott, Nicholas J.

    2018-01-01

    NESSI and `Alopeke are two new speckle imagers built at NASA's Ames Research Center for community use at the WIYN and Gemini telescopes, respectively. The two instruments are functionally similar and include the capability for wide-field imaging in additional to speckle interferometry. The diffraction-limited imaging available through speckle effectively eliminates distortions due to the presence of Earth's atmosphere by `freezing out' changes in the atmosphere by taking extremely short exposures and combining the resultant speckles in Fourier space. This technique enables angular resolutions equal to the theoretical best possible for a given telescope, effectively giving space-based resolution from the ground. Our instruments provide the highest spatial resolution available today on any single aperture telescope.A primary role of these instruments is exoplanet validation for the Kepler, K2, TESS, and many RV programs. Contrast ratios of 6 or more magnitudes are easily obtained. The instrument uses two emCCD cameras providing simultaneous dual-color observations help to characterize detected companions. High resolution imaging enables the identification of blended binaries that contaminate many exoplanet detections, leading to incorrectly measured radii. In this way small, rocky systems, such as Kepler-186b and the TRAPPIST-1 planet family, may be validated and thus the detected planets radii are correctly measured.

  16. Developing and setting up optical methods to study the speckle patterns created by optical beam smoothing

    International Nuclear Information System (INIS)

    Surville, J.

    2005-12-01

    We have developed three main optical methods to study the speckles generated by a smoothed laser source. The first method addresses the measurement of the temporal and spatial correlation functions of the source, with a modified Michelson interferometer. The second one is a pump-probe technique created to shoot a picture of a speckle pattern generated at a set time. And the third one is an evolution of the second method dedicated to time-frequency coding, thanks to a frequency chirped probe pulse. Thus, the speckles can be followed in time and their motion can be described. According to these three methods, the average size and duration of the speckles can be measured. It is also possible to measure the size and the duration of each of them and mostly their velocity in a given direction. All the results obtained have been confronted to the different existing theories. We show that the statistical distributions of the measured speckles'size and speckles'intensity agree satisfactorily with theoretical values

  17. X-ray picture of the heart turn in echocardiographic diagnosis of rheumatic heart disease

    International Nuclear Information System (INIS)

    Grishkevich, A.M.; Goryanina, N.K.

    1986-01-01

    The paper is concerned with X-ray and echocardiographic investigation of the heart in 461 patients with mitral-tricuspidal disease. In 377 (82%) cases a turn of the heart along the longitudinal axis (counter clockwise) to the left and back was revealed. X-ray recognition of the heart turn made it possible to set an echocardiographic sensor to spot some of the cardiac cavities, interventricular septum and valvular apparatus. The correct setting of the echocardiographic sensor resulted in the determination of true sizes of each cardiac cavity, diagnosis of the nature of each valvular lesion and the recognition of such complications of rheumatic heart diseases as valvular calcinosis, left atrial thrombosis and disorder of myocardial contractility

  18. Holographic interferometry and laser speckle photography as aids to assessment of pressurised components

    International Nuclear Information System (INIS)

    Martin, D.J.V.

    1975-01-01

    This summary gives defect detection holographic technique and describes laser speckle photography to evaluate in-plane movement and strain in pressurized components and conclusions. In holography no lens is used, coherent light is reflected from all points of an object to all parts of a photosensitive surface, such as a photographic plate, simultaneously light of the same wave length and coherence is made to illuminate at a different angle the same plate. These two beams, the object and the reference, cause primary fringes. The developed plate when illuminated with the reference reconstructs the original object in three dimensions. If a double exposure is made on the same plate and if parts of the object have moved between exposure the reconstructed object will be lined with secondary fringes, each fringe representing displacement down the line of sight of one wavelength of the light used. Speckle photography is the same as conventional photography excepting, that instead of using daylight or a flash lamp a coherent light beam is used. Minute points on the object illuminated by divergent laser beam act as point sources of light giving the surface a speckled appearance. In speckle photography a camera records on the plate the object and speckles. A double exposure taken on the same plate when the object has moved between exposures will, after development, when illuminated with the laser beam from Youngs fringes. Speckles and fringes are related to points on the object therefore it is possible to obtain movement and strain. The holographic tests show that it is possible to detect on the outside of tube defects in the bore approximately 10% of thickness deep. Speckle photography gives object lateral movement, direction and strain

  19. Speckle Filtering of GF-3 Polarimetric SAR Data with Joint Restriction Principle.

    Science.gov (United States)

    Xie, Jinwei; Li, Zhenfang; Zhou, Chaowei; Fang, Yuyuan; Zhang, Qingjun

    2018-05-12

    Polarimetric SAR (PolSAR) scattering characteristics of imagery are always obtained from the second order moments estimation of multi-polarization data, that is, the estimation of covariance or coherency matrices. Due to the extra-paths that signal reflected from separate scatterers within the resolution cell has to travel, speckle noise always exists in SAR images and has a severe impact on the scattering performance, especially on single look complex images. In order to achieve high accuracy in estimating covariance or coherency matrices, three aspects are taken into consideration: (1) the edges and texture of the scene are distinct after speckle filtering; (2) the statistical characteristic should be similar to the object pixel; and (3) the polarimetric scattering signature should be preserved, in addition to speckle reduction. In this paper, a joint restriction principle is proposed to meet the requirement. Three different restriction principles are introduced to the processing of speckle filtering. First, a new template, which is more suitable for the point or line targets, is designed to ensure the morphological consistency. Then, the extent sigma filter is used to restrict the pixels in the template aforementioned to have an identical statistic characteristic. At last, a polarimetric similarity factor is applied to the same pixels above, to guarantee the similar polarimetric features amongst the optional pixels. This processing procedure is named as speckle filtering with joint restriction principle and the approach is applied to GF-3 polarimetric SAR data acquired in San Francisco, CA, USA. Its effectiveness of keeping the image sharpness and preserving the scattering mechanism as well as speckle reduction is validated by the comparison with boxcar filters and refined Lee filter.

  20. Quantification of mitral regurgitation on cardiac computed tomography: comparison with qualitative and quantitative echocardiographic parameters.

    LENUS (Irish Health Repository)

    Arnous, Samer

    2012-02-01

    PURPOSE: To assess whether cardiac computed tomographic angiography (CCTA) can quantify the severity of chronic mitral regurgitation (MR) compared to qualitative and quantitative echocardiographic parameters. MATERIALS AND METHODS: Cardiac computed tomographic angiography was performed in 23 patients (mean +\\/- SD age, 63 +\\/- 16 years; range, 24-86 years) with MR and 20 patients without MR (controls) as determined by transthoracic echocardiography. Multiphasic reconstructions (20 data sets reconstructed at 5% increments of the electrocardiographic gated R-R interval) were used to analyze the mitral valve. Using CCTA planimetry, 2 readers measured the regurgitant mitral orifice area (CCTA ROA) during systole. A qualitative echocardiographic assessment of severity of MR was made by visual assessment of the length of the regurgitant jet. Quantitative echocardiographic measurements included the vena contracta, proximal isovelocity surface area, regurgitant volume, and estimated regurgitant orifice (ERO). Comparisons were performed using the independent t test, and correlations were assessed using the Spearman rank test. RESULTS: All controls and the patients with MR were correctly identified by CCTA. For patients with mild, moderate, or severe MR, mean +\\/- SD EROs were 0.16 +\\/- 0.03, 0.31 +\\/- 0.08, and 0.52 +\\/- 0.03 cm(2) (P < 0.0001) compared with mean +\\/- SD CCTA ROAs 0.09 +\\/- 0.05, 0.30 +\\/- 0.04, and 0.97 +\\/- 0.26 cm(2) (P < 0.0001), respectively. When echocardiographic measurements were graded qualitatively as mild, moderate, or severe, strong correlations were seen with CCTA ROA (R = 0.89; P < 0.001). When echocardiographic measurements were graded quantitatively, the vena contracta and the ERO showed modest correlations with CCTA ROA (0.48 and 0.50; P < 0.05 for both). Neither the proximal isovelocity surface area nor the regurgitant volume demonstrated significant correlations with CCTA ROA. CONCLUSIONS: Single-source 64-slice CCTA provides a

  1. Monitoring of bread cooling by statistical analysis of laser speckle patterns

    Science.gov (United States)

    Lyubenova, Tanya; Stoykova, Elena; Nacheva, Elena; Ivanov, Branimir; Panchev, Ivan; Sainov, Ventseslav

    2013-03-01

    The phenomenon of laser speckle can be used for detection and visualization of physical or biological activity in various objects (e.g. fruits, seeds, coatings) through statistical description of speckle dynamics. The paper presents the results of non-destructive monitoring of bread cooling by co-occurrence matrix and temporal structure function analysis of speckle patterns which have been recorded continuously within a few days. In total, 72960 and 39680 images were recorded and processed for two similar bread samples respectively. The experiments proved the expected steep decrease of activity related to the processes in the bread samples during the first several hours and revealed its oscillating character within the next few days. Characterization of activity over the bread sample surface was also obtained.

  2. Can echocardiographic findings predict falls in older persons?

    NARCIS (Netherlands)

    van der Velde, Nathalie; Stricker, Bruno H. Ch; Roelandt, Jos R. T. C.; ten Cate, Folkert J.; van der Cammen, Tischa J. M.

    2007-01-01

    BACKGROUND: The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. METHOD AND FINDINGS: In

  3. Multiple rotation assessment through isothetic fringes in speckle photography

    International Nuclear Information System (INIS)

    Angel, Luciano; Tebaldi, Myrian; Bolognini, Nestor

    2007-01-01

    The use of different pupils for storing each speckled image in speckle photography is employed to determine multiple in-plane rotations. The method consists of recording a four-exposure specklegram where the rotations are done between exposures. This specklegram is then optically processed in a whole field approach rendering isothetic fringes, which give detailed information about the multiple rotations. It is experimentally demonstrated that the proposed arrangement permits the depiction of six isothetics in order to measure either six different angles or three nonparallel components for two local general in-plane displacements

  4. Detection of radiation deformation in crystalline polymers using the speckle photography technique

    International Nuclear Information System (INIS)

    El-Ghandoor, H.; Hashem, A.A.; Sharaf, F.

    1995-01-01

    In order to measure the resulting deformation due to gamma irradiation of polymers, a new optical technique, namely speckle-photography, was established and used. Thin films of tetrafluoroethene, with constant thickness were irradiated by different doses of gamma rays and the diffraction patterns of a laser beam passing through these films were recorded using the speckle photography technique. This technique has been applied to detect the radiation deformation in (Teflon) TFE, which is a crystalline polymer. A diffraction pattern due to the TFE thin layer is obtained and superimposed on the interference pattern displaying the speckle pattern pairs recorded on the same emulsion. (author)

  5. Echocardiographic Evaluation of Patent Ductus Arteriosus in Preterm Infants

    Directory of Open Access Journals (Sweden)

    Romaine Arlettaz

    2017-06-01

    Full Text Available Patent ductus arteriosus (PDA is part of the typical morbidity profile of the preterm infant, with a high incidence of 80–90% in extremely low birth weight infants born before 26 weeks of gestation. Whereas spontaneous closure of the ductus arteriosus (DA is likely in term infants, it is less so in preterm ones. PDA is associated with increased mortality and various comorbidities including cardiac failure, need for respiratory support, bronchopulmonary dysplasia, pulmonary or intracranial hemorrhage, and necrotizing enterocolitis; however, there is no proven causality between these morbidities and the presence of DA. Thus, the indication to close PDA remains highly controversial. This paper focuses on echocardiographic evaluation of PDA in the preterm infant and particularly on the echocardiographic signs of hemodynamic significance.

  6. Early detection and treatment of Speckled leukoplakia

    Directory of Open Access Journals (Sweden)

    Selviana Tampoma

    2016-12-01

    Full Text Available Background: Leukoplakia is one of potentially malignant disorders that can be found on oral mucosa. Speckled leukoplakia is a rare type of leukoplakia with a very high risk of premalignant growth. Approximately 3 % of worldwide population has suffered from leukoplakia, 5-25% of which tend to be malignant leukoplakia. Purpose: This case report was aimed to discuss about early detection of speckled leukoplakia as one of potentially malignant disorders. Case: A 62 year old male patient came with chief complaint of bald and painful tongue since one month ago. The patient has a history of allergic reaction, hypertension, uric acid, and hepatitis B. He had been a heavy smoker since young until 10 years ago. Intra oral examination showed a firm, rough, non scrapable white plaque lesion with a size of 1 x 1.5 cm, surrounded by painful erosion with diffuse boundary. Case Management: Based on cytology examination, the patient was reffered to oncologist to get an excisional biopsy. Next, the patient succesfully underwent the excisional biopsy and came for control. The results showed the healing process of the lesion with a minimal complaint of bald tongue, especially when eating spicy or hot meal. To improve healing process, the patient then was given an antibacterial mouth rinse containing zinc and mulvitamin. Conclusion: Speckled leukoplakia could show high malignant transformation rate, therefore, early detection and treatment are necessary.

  7. Theoretical investigations on dual-beam illumination electronic speckle pattern interferometry

    International Nuclear Information System (INIS)

    Goudemand, Nicolas

    2006-01-01

    Contrary to what is found in most of the existing scientific literature,where a specific frame is developed, the theory of speckle interferometry is (conveniently) presented here as a particular case of the more general theory of holographic interferometry. In addition to the intellectual benefit of dealing with a single unified theory, this brings about many advantages when it comes to discuss fundamental topics such as the three-dimensional evolution of the complex amplitude of the diffuse optical wave fronts, the degree of approximation of the leading formulas, the loss of fringe contrast,the decorrelation effects, the real influence of the terms generally neglected in out-of-focus regions. In the same way, the statistical properties of the speckle fields, usually treated as a separate subject matter, are also integrated in the theory, thus providing a comprehensive knowledge of the qualitative features of speckle interferometry methods, otherwise difficult to understand

  8. Theoretical investigations on dual-beam illumination electronic speckle pattern interferometry

    Science.gov (United States)

    Goudemand, Nicolas

    2006-07-01

    Contrary to what is found in most of the existing scientific literature, where a specific frame is developed, the theory of speckle interferometry is (conveniently) presented here as a particular case of the more general theory of holographic interferometry. In addition to the intellectual benefit of dealing with a single unified theory, this brings about many advantages when it comes to discuss fundamental topics such as the three-dimensional evolution of the complex amplitude of the diffuse optical wavefronts, the degree of approximation of the leading formulas, the loss of fringe contrast, the decorrelation effects, the real influence of the terms generally neglected in out-of-focus regions. In the same way, the statistical properties of the speckle fields, usually treated as a separate subject matter, are also integrated in the theory, thus providing a comprehensive knowledge of the qualitative features of speckle interferometry methods, otherwise difficult to understand.

  9. Characteristics of Left Atrial Deformation Parameters and Their Prognostic Impact in Patients with Pathological Left Ventricular Hypertrophy: Analysis by Speckle Tracking Echocardiography.

    Science.gov (United States)

    Iio, Chiharuko; Inoue, Katsuji; Nishimura, Kazuhisa; Fujii, Akira; Nagai, Takayuki; Suzuki, Jun; Okura, Takafumi; Higaki, Jitsuo; Ogimoto, Akiyoshi

    2015-12-01

    The pathological process of left ventricular (LV) hypertrophy is associated with left atrial (LA) remodeling. This study was aimed to evaluate the prognostic value of LA strain parameters in patients with pathological LV hypertrophy. This study included 95 patients with hypertensive heart disease (HHD: n = 24), hypertrophic cardiomyopathy (HCM: n = 56), cardiac amyloidosis (CA: n = 15), and control subjects (n = 20). We used two-dimensional speckle tracking echocardiography (STE) to analyze LA global strain. LA electromechanical conduction time (EMT) at the septal (EMT-septal) and lateral wall (EMT-lateral), and their time difference (EMT-diff) were calculated. The incidence of cardiac death and heart failure hospitalization was defined as major cardiac events and that of atrial fibrillation as secondary outcome. Left atrial volume index was increased and LA booster strain was decreased in the HCM and CA groups compared with the HHD group. EMT-lateral was increased in the diseased groups compared with the control. EMT-diff was prolonged in the CA group compared with the HCM group. During the follow-up period (mean 3.4 years), major cardiac events and atrial fibrillation occurred in 17 and 13 patients, respectively. The occurrence of atrial fibrillation was associated with CA etiology, E/e', LA volume index, LAa, and EMT-lateral. The incidence of major cardiac events was independently correlated with LA volume index and EMT-diff in multivariate analysis. This study suggested that the EMT-diff could discriminate patients with a high risk of cardiac events among patients with pathological LV hypertrophy. © 2015, Wiley Periodicals, Inc.

  10. Tandem-pulsed acousto-optics: an analytical framework of modulated high-contrast speckle patterns

    NARCIS (Netherlands)

    Resink, Steffen; Steenbergen, Wiendelt

    2015-01-01

    Recently we presented acousto-optic (AO) probing of scattering media using addition or subtraction of speckle patterns due to tandem nanosecond pulses. Here we present a theoretical framework for ideal (polarized, noise-free) speckle patterns with unity contrast that links ultrasound-induced optical

  11. Use of three-dimensional speckle tracking to assess left ventricular myocardial mechanics: inter-vendor consistency and reproducibility of strain measurements.

    Science.gov (United States)

    Badano, Luigi P; Cucchini, Umberto; Muraru, Denisa; Al Nono, Osama; Sarais, Cristiano; Iliceto, Sabino

    2013-03-01

    Since there is insufficient data available about the inter-vendor consistency of three-dimensional (3D) speckle-tracking (STE) measurements, we undertook this study to (i) assess the inter-vendor consistency of 3D LV global strain values obtained using two different scanners; (ii) identify the sources of inter-vendor inconsistencies, if any; and (iii) compare their respective intrinsic variability. Sixty patients (38 ± 12 years, 64% males) with a wide range of LV end-diastolic volumes (from 74 to 205 ml) and ejection fractions (from 17 to 70%) underwent two 3D LV data set acquisitions using VividE9 and Artida ultrasound systems. Global longitudinal (Lε), radial (Rε), circumferential (Cε) and area (Aε) strain values were obtained offline using the corresponding 3D STE softwares. Despite being significantly different, Lε showed the closest values between the two platforms (bias = 1.5%, limits of agreement (LOA) from -2.9 to -5.9%, P < 0.05). Artida produced significantly higher values of both Cε and Aε than VividE9 (bias = 6.6, LOA: -14.1 to 0.9%, and bias = 6.0, LOA = -28.2-8.6%, respectively, P < 0.001). Conversely, Rε values obtained with Artida were significantly lower than those measured using VividE9 platform (bias = -24.2, LOA: 1.5-49.9, P < 0.001). All strain components showed good reproducibility (intra-class correlation coefficients: 0.82-0.98), except for Rε by Artida, which showed only a moderate reproducibility. Apart from Lε, the inter-vendor agreement of Rε, Cε and Aε measured with Artida and VividE9 was poor. Reference values should be specific for each system and baseline and follow-up data in longitudinal studies should be obtained using the same 3D STE platform.

  12. Real time processor for array speckle interferometry

    International Nuclear Information System (INIS)

    Chin, G.; Florez, J.; Borelli, R.; Fong, W.; Miko, J.; Trujillo, C.

    1989-01-01

    With the construction of several new large aperture telescopes and the development of large format array detectors in the near IR, the ability to obtain diffraction limited seeing via IR array speckle interferometry offers a powerful tool. We are constructing a real-time processor to acquire image frames, perform array flat-fielding, execute a 64 x 64 element 2D complex FFT, and to average the power spectrum all within the 25 msec coherence time for speckles at near IR wavelength. The processor is a compact unit controlled by a PC with real time display and data storage capability. It provides the ability to optimize observations and obtain results on the telescope rather than waiting several weeks before the data can be analyzed and viewed with off-line methods

  13. Optimized digital speckle patterns for digital image correlation by consideration of both accuracy and efficiency.

    Science.gov (United States)

    Chen, Zhenning; Shao, Xinxing; Xu, Xiangyang; He, Xiaoyuan

    2018-02-01

    The technique of digital image correlation (DIC), which has been widely used for noncontact deformation measurements in both the scientific and engineering fields, is greatly affected by the quality of speckle patterns in terms of its performance. This study was concerned with the optimization of the digital speckle pattern (DSP) for DIC in consideration of both the accuracy and efficiency. The root-mean-square error of the inverse compositional Gauss-Newton algorithm and the average number of iterations were used as quality metrics. Moreover, the influence of subset sizes and the noise level of images, which are the basic parameters in the quality assessment formulations, were also considered. The simulated binary speckle patterns were first compared with the Gaussian speckle patterns and captured DSPs. Both the single-radius and multi-radius DSPs were optimized. Experimental tests and analyses were conducted to obtain the optimized and recommended DSP. The vector diagram of the optimized speckle pattern was also uploaded as reference.

  14. Accelerated numerical processing of electronically recorded holograms with reduced speckle noise.

    Science.gov (United States)

    Trujillo, Carlos; Garcia-Sucerquia, Jorge

    2013-09-01

    The numerical reconstruction of digitally recorded holograms suffers from speckle noise. An accelerated method that uses general-purpose computing in graphics processing units to reduce that noise is shown. The proposed methodology utilizes parallelized algorithms to record, reconstruct, and superimpose multiple uncorrelated holograms of a static scene. For the best tradeoff between reduction of the speckle noise and processing time, the method records, reconstructs, and superimposes six holograms of 1024 × 1024 pixels in 68 ms; for this case, the methodology reduces the speckle noise by 58% compared with that exhibited by a single hologram. The fully parallelized method running on a commodity graphics processing unit is one order of magnitude faster than the same technique implemented on a regular CPU using its multithreading capabilities. Experimental results are shown to validate the proposal.

  15. X-ray speckle contrast variation at a sample-specific absorption edges

    International Nuclear Information System (INIS)

    Retsch, C. C.; Wang, Y.; Frigo, S. P.; Stephenson, G. B.; McNulty, I.

    2000-01-01

    The authors measured static x-ray speckle contrast variation with the incident photon energy across sample-specific absorption edges. They propose that the variation depends strongly on the spectral response function of the monochromator. Speckle techniques have been introduced to the x-ray regime during recent years. Most of these experiments, however, were done at photon energies above 5 keV. They are working on this technique in the 1 to 4 keV range, an energy range that includes many important x-ray absorption edges, e.g., in Al, Si, P, S, the rare-earths, and others. To their knowledge, the effect of absorption edges on speckle contrast has not yet been studied. In this paper, they present their initial measurements and understanding of the observed phenomena

  16. Longitudinal strain bull's eye plot patterns in patients with cardiomyopathy and concentric left ventricular hypertrophy.

    Science.gov (United States)

    Liu, Dan; Hu, Kai; Nordbeck, Peter; Ertl, Georg; Störk, Stefan; Weidemann, Frank

    2016-05-10

    Despite substantial advances in the imaging techniques and pathophysiological understanding over the last decades, identification of the underlying causes of left ventricular hypertrophy by means of echocardiographic examination remains a challenge in current clinical practice. The longitudinal strain bull's eye plot derived from 2D speckle tracking imaging offers an intuitive visual overview of the global and regional left ventricular myocardial function in a single diagram. The bull's eye mapping is clinically feasible and the plot patterns could provide clues to the etiology of cardiomyopathies. The present review summarizes the longitudinal strain, bull's eye plot features in patients with various cardiomyopathies and concentric left ventricular hypertrophy and the bull's eye plot features might serve as one of the cardiac workup steps on evaluating patients with left ventricular hypertrophy.

  17. Echocardiography Practice: Insights into Appropriate Clinical Use, Technical Competence and Quality Improvement Program

    Science.gov (United States)

    Kossaify, Antoine; Grollier, Gilles

    2014-01-01

    Echocardiography accounts for nearly half of all cardiac imaging techniques. It is a widely available and adaptable tool, as well as being a cost-effective and mainly a non-invasive test. In addition, echocardiography provides extensive clinical data, which is related to the presence or advent of different modalities (tissue Doppler imaging, speckle tracking imaging, three-dimensional mode, contrast echo, etc.), different approaches (transesophageal, intravascular, etc.), and different applications (ie, heart failure/resynchronization studies, ischemia/stress echo, etc.). In view of this, it is essential to conform to criteria of appropriate use and to keep standards of competence. In this study, we sought to review and discuss clinical practice of echocardiography in light of the criteria of appropriate clinical use, also we present an insight into echocardiographic technical competence and quality improvement project. PMID:24516342

  18. Left Ventricular Function After Prolonged Exercise in Equine Endurance Athletes

    DEFF Research Database (Denmark)

    Flethøj, M.; Schwarzwald, C. C.; Haugaard, M. M.

    2016-01-01

    Doppler imaging, and two-dimensional speckle tracking. Correlation between echocardiographic variables and cardiac troponin I was evaluated. Results: Early diastolic myocardial velocities decreased significantly in longitudinal (baseline: −17.4 ± 2.4cm/s; end of ride: −15.8 ± 3.2cm/s (P = .013); morning......Background: Prolonged exercise in human athletes is associated with transient impairment of left ventricular (LV) function, known as cardiac fatigue. Cardiac effects of prolonged exercise in horses remain unknown. Objectives :To investigate the effects of prolonged exercise on LV systolic...... and diastolic function in horses. Animals: Twenty-six horses competing in 120–160 km endurance rides. Methods: Cross-sectional field study. Echocardiography was performed before and after rides, and the following morning, and included two-dimensional echocardiography, anatomical M-mode, pulsed-wave tissue...

  19. Childhood acquired heart disease in Nigeria: an echocardiographic ...

    African Journals Online (AJOL)

    Introduction: Acquired heart diseases (AHD) are not uncommon in children. The current multi-center study aims to provide a more representative data of AHD in Nigeria. Methods: Over 42 months, children referred for echocardiographic evaluation who had confirmed AHD in three centers in Nigeria were recruited. The data ...

  20. Analysis of the speckle properties in a laser projection system based on a human eye model.

    Science.gov (United States)

    Cui, Zhe; Wang, Anting; Ma, Qianli; Ming, Hai

    2014-03-01

    In this paper, the properties of the speckle that is observed by humans in laser projection systems are theoretically analyzed. The speckle pattern on the fovea of the human retina is numerically simulated by introducing a chromatic human eye model. The results show that the speckle contrast experienced by humans is affected by the light intensity of the projected images and the wavelength of the laser source when considering the paracentral vision. Furthermore, the image quality is also affected by these two parameters. We believe that these results are useful for evaluating the speckle noise in laser projection systems.

  1. Single-shot speckle reduction in numerical reconstruction of digitally recorded holograms.

    Science.gov (United States)

    Hincapie, Diego; Herrera-Ramírez, Jorge; Garcia-Sucerquia, Jorge

    2015-04-15

    A single-shot method to reduce the speckle noise in the numerical reconstructions of electronically recorded holograms is presented. A recorded hologram with the dimensions N×M is split into S=T×T sub-holograms. The uncorrelated superposition of the individually reconstructed sub-holograms leads to an image with the speckle noise reduced proportionally to the 1/S law. The experimental results are presented to support the proposed methodology.

  2. Anomalous Aortic Origin of Coronary Arteries in the Young: Echocardiographic Evaluation With Surgical Correlation.

    Science.gov (United States)

    Lorber, Richard; Srivastava, Shubhika; Wilder, Travis J; McIntyre, Susan; DeCampli, William M; Williams, William G; Frommelt, Peter C; Parness, Ira A; Blackstone, Eugene H; Jacobs, Marshall L; Mertens, Luc; Brothers, Julie A; Herlong, J René

    2015-11-01

    This study sought to compare findings from institutional echocardiographic reports with imaging core laboratory (ICL) review of corresponding echocardiographic images and operative reports in 159 patients with anomalous aortic origin of a coronary artery (AAOCA). The study also sought to develop a "best practice" protocol for imaging and interpreting images in establishing the diagnosis of AAOCA. AAOCA is associated with sudden death in the young. Underlying anatomic risk factors that can cause ischemia-related events include coronary arterial ostial stenosis, intramural course of the proximal coronary within the aortic wall, interarterial course, and potential compression between the great arteries. Consistent protocols for diagnosing and evaluating these features are lacking, potentially precluding the ability to risk stratify patients based on evidence and plan surgical strategy. For a prescribed set of anatomic AAOCA features, percentages of missing data in institutional echocardiographic reports were calculated. For each feature, agreement among institutional echocardiographic reports, ICL review of images, and surgical reports was evaluated using the weighted kappa statistic. An echocardiographic imaging protocol was developed heuristically to reduce differences between institutional reports and ICL review. A total of 13%, 33%, and 62% of echocardiograms were missing images enabling diagnosis of intra-arterial course, proximal intramural course, and high ostial takeoff, respectively. There was poor agreement between institutional reports and ICL review for diagnosis of origin of coronary artery, interarterial course, intramural course, and acute angle takeoff (kappa = 0.74, 0.11, -0.03, 0.13, respectively). Surgical findings were also significantly different from those of reports, and to a lesser extent ICL reviews. The resulting protocol contains technical recommendations for imaging each of these features. Poor agreement between institutional reports and

  3. Position control of ECRH launcher mirrors by laser speckle sensor

    International Nuclear Information System (INIS)

    Michelsen, Poul K.; Bindslev, Henrik; Hansen, Rene Skov; Hanson, Steen G.

    2003-01-01

    The planned ECRH system for JET included several fixed and steerable mirrors some of which should have been fixed to the building structure and some to the JET vessel structure. A similar system may be anticipated for ITER and for other fusion devices in the future. In order to have high reproducibility of the ECRH beam direction, it is necessary to know the exact positions of the mirrors. This is not a trivial problem because of thermal expansion of the vessel structures and of the launcher itself and of its support structure, the mechanical load on mirrors and support structures, and the accessibility to the various mirrors. We suggest to use a combination of infrared diagnostic of beam spot positions and a new technique published recently, which is based on a non-contact laser speckle sensor for measuring one- and two-dimensional angular displacement. The method is based on Fourier transforming the scattered field from a single laser beam that illuminates the target. The angular distribution of the light field at the target is linearly mapped onto an array image sensor placed in the Fourier plane. Measuring the displacement of this so-called speckle pattern facilitates the determination of the mirror orientation. Transverse target movement can be measured by observing the speckle movement in the image plane of the object. No special surface treatment is required for surfaces having irregularities of the order of or larger than the wavelength of the incident light. For the JET ECRH launcher it is mainly for the last mirror pointing towards the plasma where the technique may be useful. This mirror has to be steerable in order to reflect the microwave beam in the correct direction towards the plasma. Maximum performance of the microwave heating requires that the beam hits this mirror at its centre and that the mirror is turned in the correct angle. Inaccuracies in the positioning of the pull rods for controlling the mirror turning and thermal effects makes it

  4. Echocardiographic study of left atrial myxoma

    Directory of Open Access Journals (Sweden)

    Dalal J

    1979-01-01

    Full Text Available Four cases of left atrial myxoma were diagnosed pre-operatively by echocardiography. All cases showed characteristic echocardio-graphic features of variegated shadows behind the mitral valve in diastole and within the left atrium in systole. In two cases the my-xomas were surgically removed and confirmed on histology. In one case the post-operative echocardiogram showed complete dis-appearance of the abnormal shadows. Echocardiography is the most reliable method today for the diagnosis of a myxoma.

  5. Enhanced diagnostic of skin conditions by polarized laser speckles: phantom studies and computer modeling

    Science.gov (United States)

    Tchvialeva, Lioudmila; Lee, Tim K.; Markhvida, Igor; Zeng, Haishan; Doronin, Alexander; Meglinski, Igor

    2014-03-01

    The incidence of the skin melanoma, the most commonly fatal form of skin cancer, is increasing faster than any other potentially preventable cancer. Clinical practice is currently hampered by the lack of the ability to rapidly screen the functional and morphological properties of tissues. In our previous study we show that the quantification of scattered laser light polarization provides a useful metrics for diagnostics of the malignant melanoma. In this study we exploit whether the image speckle could improve skin cancer diagnostic in comparison with the previously used free-space speckle. The study includes skin phantom measurements and computer modeling. To characterize the depolarization of light we measure the spatial distribution of speckle patterns and analyse their depolarization ratio taken into account radial symmetry. We examine the dependences of depolarization ratio vs. roughness for phantoms which optical properties are of the order of skin lesions. We demonstrate that the variation in bulk optical properties initiates the assessable changes in the depolarization ratio. We show that image speckle differentiates phantoms significantly better than free-space speckle. The results of experimental measurements are compared with the results of Monte Carlo simulation.

  6. Synchronized renal blood flow dynamics mapped with wavelet analysis of laser speckle flowmetry data

    DEFF Research Database (Denmark)

    Brazhe, Alexey R; Marsh, Donald J; von Holstein-Rathlou, Niels-Henrik

    2014-01-01

    of rat kidneys. The regulatory mechanism in the renal microcirculation generates oscillations in arterial blood flow at several characteristic frequencies. Our approach to laser speckle image processing allows detection of frequency and phase entrainments, visualization of their patterns, and estimation......Full-field laser speckle microscopy provides real-time imaging of superficial blood flow rate. Here we apply continuous wavelet transform to time series of speckle-estimated blood flow from each pixel of the images to map synchronous patterns in instantaneous frequency and phase on the surface...... of the extent of synchronization in renal cortex dynamics....

  7. Intravenous carbon dioxide as an echocardiographic contrast agent

    NARCIS (Netherlands)

    R.S. Meltzer (Richard); P.W.J.C. Serruys (Patrick); P.G. Hugenholtz (Paul); J.R.T.C. Roelandt (Jos)

    1981-01-01

    textabstractIntravenous carbon dioxide (CO2) was employed to cause echocardiographic contrast in 40 patients. One to 3 cc of medically pure CO2 were agitated with 5 to 8 cc of 5% dextrose in water and rapidly injected into an upper extremity vein. Contrast was obtained in all patients. In 33

  8. Morphologic-echocardiographic correlates of Ebstein's malformation.

    Science.gov (United States)

    Rusconi, P G; Zuberbuhler, J R; Anderson, R H; Rigby, M L

    1991-07-01

    The cross-sectional echocardiographic findings were analysed retrospectively in 26 patients with Ebstein's malformation in the light of studies of autopsied specimens from different patients showing this lesion. The salient anatomical feature in diagnosis is the finding of the hinge point of the septal and mural leaflets of the valve within the inlet component of the right ventricle rather than at the atrioventricular junction. The other important feature is the nature of the distal attachment of the leaflets, particularly the anterosuperior one, which can either be in focal or linear fashion. The hinge point of the septal leaflet was noted echocardiographically to be displaced in 19 patients but, significantly, the leaflet was absent in the other seven. Also significant was that the hinge point of the mural leaflet at the crux had been visualized in only 15 of the patients. The anterosuperior leaflet had a distal linear attachment in 20 of the patients, with the anteroseptal commissure becoming a keyhole in six of these through which blood passed to the functional right ventricle. The valve remained a competent structure, even though closing at the junction of atrialized and functional components of the right ventricle rather than at the atrioventricular junction. Cross-sectional echocardiography is the technique of choice with which to display the salient morphological features of Ebstein's malformation.

  9. Development and Implementation of a Quality Improvement Process for Echocardiographic Laboratory Accreditation.

    Science.gov (United States)

    Gilliland, Yvonne E; Lavie, Carl J; Ahmad, Homaa; Bernal, Jose A; Cash, Michael E; Dinshaw, Homeyar; Milani, Richard V; Shah, Sangeeta; Bienvenu, Lisa; White, Christopher J

    2016-03-01

    We describe our process for quality improvement (QI) for a 3-year accreditation cycle in echocardiography by the Intersocietal Accreditation Commission (IAC) for a large group practice. Echocardiographic laboratory accreditation by the IAC was introduced in 1996, which is not required but could impact reimbursement. To ensure high-quality patient care and community recognition as a facility committed to providing high-quality echocardiographic services, we applied for IAC accreditation in 2010. Currently, there is little published data regarding the IAC process to meet echocardiography standards. We describe our approach for developing a multicampus QI process for echocardiographic laboratory accreditation during the 3-year cycle of accreditation by the IAC. We developed a quarterly review assessing (1) the variability of the interpretations, (2) the quality of the examinations, (3) a correlation of echocardiographic studies with other imaging modalities, (4) the timely completion of reports, (5) procedure volume, (6) maintenance of Continuing Medical Education credits by faculty, and (7) meeting Appropriate Use Criteria. We developed and implemented a multicampus process for QI during the 3-year accreditation cycle by the IAC for Echocardiography. We documented both the process and the achievement of those metrics by the Echocardiography Laboratories at the Ochsner Medical Institutions. We found the QI process using IAC standards to be a continuous educational experience for our Echocardiography Laboratory physicians and staff. We offer our process as an example and guide for other echocardiography laboratories who wish to apply for such accreditation or reaccreditation. © 2016, Wiley Periodicals, Inc.

  10. Thermoregulation under semi-natural conditions in speckled ...

    African Journals Online (AJOL)

    We recorded body temperature (Tb) in speckled mousebirds (Colius striatus) under semi-natural conditions in outdoor aviaries, and examined interactions between behavioural and metabolic thermoregulation by experimentally manipulating food availability and communal roosting behaviour. When food was available ad ...

  11. Multiresolution edge detection using enhanced fuzzy c-means clustering for ultrasound image speckle reduction

    Energy Technology Data Exchange (ETDEWEB)

    Tsantis, Stavros [Department of Medical Physics, School of Medicine, University of Patras, Rion, GR 26504 (Greece); Spiliopoulos, Stavros; Karnabatidis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion, GR 26504 (Greece); Skouroliakou, Aikaterini [Department of Energy Technology Engineering, Technological Education Institute of Athens, Athens 12210 (Greece); Hazle, John D. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Kagadis, George C., E-mail: gkagad@gmail.com, E-mail: George.Kagadis@med.upatras.gr, E-mail: GKagadis@mdanderson.org [Department of Medical Physics, School of Medicine, University of Patras, Rion, GR 26504, Greece and Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

    2014-07-15

    Purpose: Speckle suppression in ultrasound (US) images of various anatomic structures via a novel speckle noise reduction algorithm. Methods: The proposed algorithm employs an enhanced fuzzy c-means (EFCM) clustering and multiresolution wavelet analysis to distinguish edges from speckle noise in US images. The edge detection procedure involves a coarse-to-fine strategy with spatial and interscale constraints so as to classify wavelet local maxima distribution at different frequency bands. As an outcome, an edge map across scales is derived whereas the wavelet coefficients that correspond to speckle are suppressed in the inverse wavelet transform acquiring the denoised US image. Results: A total of 34 thyroid, liver, and breast US examinations were performed on a Logiq 9 US system. Each of these images was subjected to the proposed EFCM algorithm and, for comparison, to commercial speckle reduction imaging (SRI) software and another well-known denoising approach, Pizurica's method. The quantification of the speckle suppression performance in the selected set of US images was carried out via Speckle Suppression Index (SSI) with results of 0.61, 0.71, and 0.73 for EFCM, SRI, and Pizurica's methods, respectively. Peak signal-to-noise ratios of 35.12, 33.95, and 29.78 and edge preservation indices of 0.94, 0.93, and 0.86 were found for the EFCM, SIR, and Pizurica's method, respectively, demonstrating that the proposed method achieves superior speckle reduction performance and edge preservation properties. Based on two independent radiologists’ qualitative evaluation the proposed method significantly improved image characteristics over standard baseline B mode images, and those processed with the Pizurica's method. Furthermore, it yielded results similar to those for SRI for breast and thyroid images significantly better results than SRI for liver imaging, thus improving diagnostic accuracy in both superficial and in-depth structures. Conclusions: A

  12. Multiresolution edge detection using enhanced fuzzy c-means clustering for ultrasound image speckle reduction

    International Nuclear Information System (INIS)

    Tsantis, Stavros; Spiliopoulos, Stavros; Karnabatidis, Dimitrios; Skouroliakou, Aikaterini; Hazle, John D.; Kagadis, George C.

    2014-01-01

    Purpose: Speckle suppression in ultrasound (US) images of various anatomic structures via a novel speckle noise reduction algorithm. Methods: The proposed algorithm employs an enhanced fuzzy c-means (EFCM) clustering and multiresolution wavelet analysis to distinguish edges from speckle noise in US images. The edge detection procedure involves a coarse-to-fine strategy with spatial and interscale constraints so as to classify wavelet local maxima distribution at different frequency bands. As an outcome, an edge map across scales is derived whereas the wavelet coefficients that correspond to speckle are suppressed in the inverse wavelet transform acquiring the denoised US image. Results: A total of 34 thyroid, liver, and breast US examinations were performed on a Logiq 9 US system. Each of these images was subjected to the proposed EFCM algorithm and, for comparison, to commercial speckle reduction imaging (SRI) software and another well-known denoising approach, Pizurica's method. The quantification of the speckle suppression performance in the selected set of US images was carried out via Speckle Suppression Index (SSI) with results of 0.61, 0.71, and 0.73 for EFCM, SRI, and Pizurica's methods, respectively. Peak signal-to-noise ratios of 35.12, 33.95, and 29.78 and edge preservation indices of 0.94, 0.93, and 0.86 were found for the EFCM, SIR, and Pizurica's method, respectively, demonstrating that the proposed method achieves superior speckle reduction performance and edge preservation properties. Based on two independent radiologists’ qualitative evaluation the proposed method significantly improved image characteristics over standard baseline B mode images, and those processed with the Pizurica's method. Furthermore, it yielded results similar to those for SRI for breast and thyroid images significantly better results than SRI for liver imaging, thus improving diagnostic accuracy in both superficial and in-depth structures. Conclusions: A

  13. Right ventricular strain in heart failure: Clinical perspective.

    Science.gov (United States)

    Tadic, Marijana; Pieske-Kraigher, Elisabeth; Cuspidi, Cesare; Morris, Daniel A; Burkhardt, Franziska; Baudisch, Ana; Haßfeld, Sabine; Tschöpe, Carsten; Pieske, Burket

    2017-10-01

    The number of studies demonstrating the importance of right ventricular remodelling in a wide range of cardiovascular diseases has increased in the past two decades. Speckle-tracking imaging provides new variables that give comprehensive information about right ventricular function and mechanics. In this review, we summarize current knowledge of right ventricular mechanics in heart failure with reduced ejection fraction and preserved ejection fraction. We searched PubMed, MEDLINE, Ovid and Embase databases for studies published from January 2000 to December 2016 in the English language using the following keywords: "right ventricle"; "strain"; "speckle tracking"; "heart failure with reduced ejection fraction"; and "heart failure with preserved ejection fraction". Investigations showed that right ventricular dysfunction is associated with higher cardiovascular and overall mortality in patients with heart failure, irrespective of ejection fraction. The number of studies investigating right ventricular strain in patients with heart failure with reduced ejection fraction is constantly increasing, whereas data on right ventricular mechanics in patients with heart failure with preserved ejection fraction are limited. Given the high feasibility, accuracy and clinical implications of right ventricular strain in the population with heart failure, it is of great importance to try to include the evaluation of right ventricular strain as a regular part of each echocardiographic examination in patients with heart failure. However, further investigations are necessary to establish right ventricular strain as a standard variable for decision-making. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Future Perspectives for Management of Stage A Heart Failure.

    Science.gov (United States)

    Tanaka, Hidekazu

    2018-05-07

    Patients with Stage A heart failure (HF) show no HF symptoms but have related comorbid diseases with a high risk of progressing to HF. Screening for comorbid diseases warrants closer attention because of the growing interest in addressing Stage A HF as the best means of preventing eventual progression to overt HF such as Stages C and D. The identification of individuals of Stage A HF is potentially useful for the implementation of HF-prevention strategies; however, not all Stage A HF patients develop left ventricular (LV) structural heart disease or symptomatic HF, which lead to advanced HF stages. Therefore, Stage A HF requires management with the long-term goal of avoiding HF development; likewise, Stage B HF patients are ideal targets for HF prevention. Although the early detection of subclinical LV dysfunction is, thus, essential for delaying the progression to HF, the assessment of subclinical LV dysfunction can be challenging. Global longitudinal strain (GLS) as assessed by speckle-tracking echocardiography has recently been reported to be a sensitive marker of early subtle LV myocardial abnormalities, helpful for the prediction of the outcomes for various cardiac diseases, and superior to conventional echocardiographic indices. GLS reflects LV longitudinal myocardial systolic function, and can be assessed usually by means of two-dimensional speckle-tracking. This article reviews the importance of the assessment of subclinical LV dysfunction in Stage A HF patients by means of GLS, and its current potential to prevent progression to later stage HF.

  15. Noninvasive model including right ventricular speckle tracking for the evaluation of pulmonary hypertension.

    Science.gov (United States)

    Mahran, Yossra; Schueler, Robert; Weber, Marcel; Pizarro, Carmen; Nickenig, Georg; Skowasch, Dirk; Hammerstingl, Christoph

    2016-08-26

    To find parameters from transthorathic echocardiography (TTE) including speckle-tracking (ST) analysis of the right ventricle (RV) to identify precapillary pulmonary hypertension (PH). Forty-four patients with suspected PH undergoing right heart catheterization (RHC) were consecutively included (mean age 63.1 ± 14 years, 61% male gender). All patients underwent standardized TTE including ST analysis of the RV. Based on the subsequent TTE-derived measurements, the presence of PH was assessed: Left ventricular ejection fraction (LVEF) was calculated by Simpsons rule from 4Ch. Systolic pulmonary artery pressure (sPAP) was assessed with continuous wave Doppler of systolic tricuspid regurgitant velocity and regarded raised with values ≥ 30 mmHg as a surrogate parameter for RA pressure. A concomitantly elevated PCWP was considered a means to discriminate between the precapillary and postcapillary form of PH. PCWP was considered elevated when the E/e' ratio was > 12 as a surrogate for LV diastolic pressure. E/e' ratio was measured by gauging systolic and diastolic velocities of the lateral and septal mitral valve annulus using TDI mode. The results were then averaged with conventional measurement of mitral valve inflow. Furthermore, functional testing with six minutes walking distance (6MWD), ECG-RV stress signs, NT pro-BNP and other laboratory values were assessed. PH was confirmed in 34 patients (precapillary PH, n = 15, postcapillary PH, n = 19). TTE showed significant differences in E/e' ratio (precapillary PH: 12.3 ± 4.4, postcapillary PH: 17.3 ± 10.3, no PH: 12.1 ± 4.5, P = 0.02), LV volumes (ESV: 25.0 ± 15.0 mL, 49.9 ± 29.5 mL, 32.2 ± 13.6 mL, P = 0.027; EDV: 73.6 ± 24.0 mL, 110.6 ± 31.8 mL, 87.8 ± 33.0 mL, P = 0.021) and systolic pulmonary arterial pressure (sPAP: 61.2 ± 22.3 mmHg, 53.6 ± 20.1 mmHg, 31.2 ± 24.6 mmHg, P = 0.001). STRV analysis showed significant differences for apical RV longitudinal strain (RVAS: -7.5% ± 5.6%, -13.3% ± 4.3%, -14

  16. CDKL5 influences RNA splicing activity by its association to the nuclear speckle molecular machinery.

    Science.gov (United States)

    Ricciardi, Sara; Kilstrup-Nielsen, Charlotte; Bienvenu, Thierry; Jacquette, Aurélia; Landsberger, Nicoletta; Broccoli, Vania

    2009-12-01

    Mutations in the human X-linked cyclin-dependent kinase-like 5 (CDKL5) gene have been shown to cause severe neurodevelopmental disorders including infantile spasms, encephalopathy, West-syndrome and an early-onset variant of Rett syndrome. CDKL5 is a serine/threonine kinase whose involvement in Rett syndrome can be inferred by its ability to directly bind and mediate phosphorylation of MeCP2. However, it remains to be elucidated how CDKL5 exerts its function. Here, we report that CDKL5 localizes to specific nuclear foci referred to as nuclear speckles in both cell lines and tissues. These sub-nuclear structures are traditionally considered as storage/modification sites of pre-mRNA splicing factors. Interestingly, we provide evidence that CDKL5 regulates the dynamic behaviour of nuclear speckles. Indeed, CDKL5 overexpression leads to nuclear speckle disassembly, and this event is strictly dependent on its kinase activity. Conversely, its down-regulation affects nuclear speckle morphology leading to abnormally large and uneven speckles. Similar results were obtained for primary adult fibroblasts isolated from CDKL5-mutated patients. Altogether, these findings indicate that CDKL5 controls nuclear speckle morphology probably by regulating the phosphorylation state of splicing regulatory proteins. Nuclear speckles are dynamic sites that can continuously supply splicing factors to active transcription sites, where splicing occurs. Notably, we proved that CDKL5 influences alternative splicing, at least as proved in heterologous minigene assays. In conclusion, we provide evidence that CDKL5 is involved indirectly in pre-mRNA processing, by controlling splicing factor dynamics. These findings identify a biological process whose disregulation might affect neuronal maturation and activity in CDKL5-related disorders.

  17. Speckle reduction techniques in digital holography

    Energy Technology Data Exchange (ETDEWEB)

    Monaghan, David; Kelly, Damien; Hennelly, Bryan [Department of Computer Science, National University of Ireland, Maynooth, Co. Kildare (Ireland); Javidi, Bahram, E-mail: bryanh@cs.nuim.i [University of Connecticut Electrical and Computer Engineering Department 371 Fairfield Road, Unit 2157 Storrs, CT 06269-2157 (United States)

    2010-02-01

    We have studied several speckle reduction techniques, applicable to digital holography. These include the use of optical diffusers, wavelet filtering, simulating temporal incoherence and filtering in the Fourier domain. The Digital Holograms (DHs) used in this study are captured using a Phase Shift Interferometric (PSI) in-line setup and subsequently reconstructed numerically.

  18. Effect of static scatterers in laser speckle contrast imaging: an experimental study on correlation and contrast

    Science.gov (United States)

    Vaz, Pedro G.; Humeau-Heurtier, Anne; Figueiras, Edite; Correia, Carlos; Cardoso, João

    2018-01-01

    Laser speckle contrast imaging (LSCI) is a non-invasive microvascular blood flow assessment technique with good temporal and spatial resolution. Most LSCI systems, including commercial devices, can perform only qualitative blood flow evaluation, which is a major limitation of this technique. There are several factors that prevent the utilization of LSCI as a quantitative technique. Among these factors, we can highlight the effect of static scatterers. The goal of this work was to study the influence of differences in static and dynamic scatterer concentration on laser speckle correlation and contrast. In order to achieve this, a laser speckle prototype was developed and tested using an optical phantom with various concentrations of static and dynamic scatterers. It was found that the laser speckle correlation could be used to estimate the relative concentration of static/dynamic scatterers within a sample. Moreover, the speckle correlation proved to be independent of the dynamic scatterer velocity, which is a fundamental characteristic to be used in contrast correction.

  19. SPECKLE OBSERVATIONS OF BINARY STARS WITH THE WIYN TELESCOPE. VII. MEASURES DURING 2008-2009

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Bahi, Lizzie Anne P.; Gaulin, Joseph R.; Howell, Steve B.; Sherry, William H.; Baena Gallé, Roberto; Van Altena, William F.

    2012-01-01

    Five hundred thirty-one speckle measures of binary stars are reported. These data were taken mainly during the period 2008 June through 2009 October at the WIYN 3.5 m Telescope at Kitt Peak and represent the last data set of single-filter speckle observations taken in the WIYN speckle program prior to the use of the current two-channel speckle camera. The astrometric and photometric precision of these observations is consistent with previous papers in this series: we obtain a typical linear measurement uncertainty of approximately 2.5 mas, and the magnitude differences reported have typical uncertainties in the range of 0.1-0.14 mag. In combination with measures already in the literature, the data presented here permit the revision of the orbit of A 1634AB (= HIP 76041) and the first determination of visual orbital elements for HDS 1895 (= HIP 65982).

  20. Comparison of phase unwrapping algorithms for topography reconstruction based on digital speckle pattern interferometry

    Science.gov (United States)

    Li, Yuanbo; Cui, Xiaoqian; Wang, Hongbei; Zhao, Mengge; Ding, Hongbin

    2017-10-01

    Digital speckle pattern interferometry (DSPI) can diagnose the topography evolution in real-time, continuous and non-destructive, and has been considered as a most promising technique for Plasma-Facing Components (PFCs) topography diagnostic under the complicated environment of tokamak. It is important for the study of digital speckle pattern interferometry to enhance speckle patterns and obtain the real topography of the ablated crater. In this paper, two kinds of numerical model based on flood-fill algorithm has been developed to obtain the real profile by unwrapping from the wrapped phase in speckle interference pattern, which can be calculated through four intensity images by means of 4-step phase-shifting technique. During the process of phase unwrapping by means of flood-fill algorithm, since the existence of noise pollution, and other inevitable factors will lead to poor quality of the reconstruction results, this will have an impact on the authenticity of the restored topography. The calculation of the quality parameters was introduced to obtain the quality-map from the wrapped phase map, this work presents two different methods to calculate the quality parameters. Then quality parameters are used to guide the path of flood-fill algorithm, and the pixels with good quality parameters are given priority calculation, so that the quality of speckle interference pattern reconstruction results are improved. According to the comparison between the flood-fill algorithm which is suitable for speckle pattern interferometry and the quality-guided flood-fill algorithm (with two different calculation approaches), the errors which caused by noise pollution and the discontinuous of the strips were successfully reduced.

  1. En face speckle reduction in optical coherence microscopy by frequency compounding.

    Science.gov (United States)

    Magnain, Caroline; Wang, Hui; Sakadžić, Sava; Fischl, Bruce; Boas, David A

    2016-05-01

    We report the use of frequency compounding to significantly reduce speckle noise in optical coherence microscopy, more specifically on the en face images. This method relies on the fact that the speckle patterns recorded from different wavelengths simultaneously are independent; hence their summation yields significant reduction in noise, with only a single acquisition. The results of our experiments with microbeads show that the narrow confocal parameter, due to a high numerical aperture objective, restricts the axial resolution loss that would otherwise theoretically broaden linearly with the number of optical frequency bands used. This speckle reduction scheme preserves the lateral resolution since it is performed on individual A-scans. Finally, we apply this technique to images of fixed human brain tissue, showing significant improvements in contrast-to-noise ratio with only moderate loss of axial resolution, in an effort to improve automatic three-dimensional detection of cells and fibers in the cortex.

  2. The Study Of Optometry Apparatus Of Laser Speckles

    Science.gov (United States)

    Bao-cheng, Wang; Kun, Yao; Xiu-qing, Wu; Chang-ying, Long; Jia-qi, Shi; Shi-zhong, Shi

    1988-01-01

    Based on the regularity of laser speckles movement the method of exam the uncorrected eyes is determined. The apparatus with micro-computer and optical transformation is made. Its practical function is excellent.

  3. Recruitment of phosphorylated small heat shock protein Hsp27 to nuclear speckles without stress

    International Nuclear Information System (INIS)

    Bryantsev, A.L.; Chechenova, M.B.; Shelden, E.A.

    2007-01-01

    During stress, the mammalian small heat shock protein Hsp27 enters cell nuclei. The present study examines the requirements for entry of Hsp27 into nuclei of normal rat kidney (NRK) renal epithelial cells, and for its interactions with specific nuclear structures. We find that phosphorylation of Hsp27 is necessary for the efficient entry into nuclei during heat shock but not sufficient for efficient nuclear entry under control conditions. We further report that Hsp27 is recruited to an RNAse sensitive fraction of SC35 positive nuclear speckles, but not other intranuclear structures, in response to heat shock. Intriguingly, Hsp27 phosphorylation, in the absence of stress, is sufficient for recruitment to speckles found in post-anaphase stage mitotic cells. Additionally, pseudophosphorylated Hsp27 fused to a nuclear localization peptide (NLS) is recruited to nuclear speckles in unstressed interphase cells, but wildtype and nonphosphorylatable Hsp27 NLS fusion proteins are not. The expression of NLS-Hsp27 mutants does not enhance colony forming abilities of cells subjected to severe heat shock, but does regulate nuclear speckle morphology. These data demonstrate that phosphorylation, but not stress, mediates Hsp27 recruitment to an RNAse soluble fraction of nuclear speckles and support a site-specific role for Hsp27 within the nucleus

  4. Sound recovery via intensity variations of speckle pattern pixels selected with variance-based method

    Science.gov (United States)

    Zhu, Ge; Yao, Xu-Ri; Qiu, Peng; Mahmood, Waqas; Yu, Wen-Kai; Sun, Zhi-Bin; Zhai, Guang-Jie; Zhao, Qing

    2018-02-01

    In general, the sound waves can cause the vibration of the objects that are encountered in the traveling path. If we make a laser beam illuminate the rough surface of an object, it will be scattered into a speckle pattern that vibrates with these sound waves. Here, an efficient variance-based method is proposed to recover the sound information from speckle patterns captured by a high-speed camera. This method allows us to select the proper pixels that have large variances of the gray-value variations over time, from a small region of the speckle patterns. The gray-value variations of these pixels are summed together according to a simple model to recover the sound with a high signal-to-noise ratio. Meanwhile, our method will significantly simplify the computation compared with the traditional digital-image-correlation technique. The effectiveness of the proposed method has been verified by applying a variety of objects. The experimental results illustrate that the proposed method is robust to the quality of the speckle patterns and costs more than one-order less time to perform the same number of the speckle patterns. In our experiment, a sound signal of time duration 1.876 s is recovered from various objects with time consumption of 5.38 s only.

  5. Echocardiographic screening for subclinical rheumatic heart disease remains a research tool pending studies of impact on prognosis.

    Science.gov (United States)

    Zühlke, Liesl; Mayosi, Bongani M

    2013-03-01

    The application of portable echocardiography to the screening of asymptomatic children and young adults for rheumatic heart disease (RHD) in developing countries indicates that the disease may affect 62 million to 78 million individuals worldwide, which could potentially result in 1.4 million deaths per year from RHD and its complications. The World Heart Federation has developed a guideline for the echocardiographic diagnosis of RHD in asymptomatic individuals without a history of acute rheumatic fever (ARF) in order to ensure the reliability, comparability, and reproducibility of findings of the echocardiographic screening studies. Early studies suggest that a third of individuals with asymptomatic subclinical RHD revert to normal echocardiographic findings on repeat testing after 6-12 months, suggesting that repeat echocardiography may be necessary to confirm the findings prior to consideration of interventions such as antibiotic prophylaxis. It is not known, however, whether echocardiographic screening for asymptomatic subclinical RHD or the introduction of antibiotic prophylaxis for affected individuals improves the prognosis of RHD. Furthermore, the cost-effectiveness of this screening method has not been established in the vast majority of affected countries. Therefore, echocardiographic screening for asymptomatic subclinical RHD remains a research tool until studies of impact on prognosis and cost-effectiveness are conducted.

  6. Complementary Speckle Patterns: Deterministic Interchange of Intrinsic Vortices and Maxima through Scattering Media.

    Science.gov (United States)

    Gateau, Jérôme; Rigneault, Hervé; Guillon, Marc

    2017-01-27

    Intensity maxima and zeros of speckle patterns obtained behind a diffuser are experimentally interchanged by applying a spiral phase delay of charge ±1 to the impinging coherent beam. This transform arises from the expectation that tightly focused beams, which have a planar wave front around the focus, are so changed into vortex beams and vice versa. The statistics of extrema locations and the intensity distribution of the so-generated "complementary" patterns are characterized by numerical simulations. It is demonstrated experimentally that the incoherent superposition of the three "complementary speckle patterns" yield a synthetic speckle grain size enlarged by a factor of sqrt[3]. A cyclic permutation of optical vortices and intensity maxima is unexpectedly observed and discussed.

  7. Echocardiographic right ventricle longitudinal contraction indices cannot predict ejection fraction in post-operative Fallot children.

    Science.gov (United States)

    Bonnemains, Laurent; Stos, Bertrand; Vaugrenard, Thibaud; Marie, Pierre-Yves; Odille, Freddy; Boudjemline, Younes

    2012-03-01

    To examine in a population of post-operative tetralogy of Fallot patients, the correlation between right ventricle (RV) ejection fractions (EF) computed from magnetic resonance imaging (MRI) and three echocardiographic indices of RV function: TAPSE, longitudinal strain and strain rate. Indeed, these patients present a pulmonary regurgitation which is responsible for progressive dilatation of the RV. An echocardiographic assessment of the RV function would be very useful in determining the timing of pulmonary revalvulation for Fallot patients. However, these indices are generally based on the ventricle contraction in the long axis direction which is impaired in this population and does not seem to correlate with the EF. Thirty-five post-operative tetralogy of Fallot patients and 20 patients with normal RVs were included. In both groups, RVEF, assessed by MRI, was compared with the three echocardiographic indices. Longitudinal strain and strain rates were computed both on the free wall and on the whole RV. No correlation was found between the echocardiographic indices and the MRI EF in our Fallot population. The accuracy of those indices as a diagnostic test of an altered RV was low with Younden's indices varying from -0.18 to 0.5 and areas under the Receiver Operating Characterictic (ROC) curves equal to 0.54 for tricuspid annulus plane systolic excursion, 0.59-0.62 for strain and 0.57-0.63 for strain rate. Three conventional echocardiographic indices based on RV longitudinal contraction failed to assess the EF in our population of post-operative tetralogy of Fallot patients.

  8. Echocardiographic Image Quality Deteriorates with Age in Children and Young Adults with Duchenne Muscular Dystrophy.

    Science.gov (United States)

    Power, Alyssa; Poonja, Sabrina; Disler, Dal; Myers, Kimberley; Patton, David J; Mah, Jean K; Fine, Nowell M; Greenway, Steven C

    2017-01-01

    Advances in medical care for patients with Duchenne muscular dystrophy (DMD) have resulted in improved survival and an increased prevalence of cardiomyopathy. Serial echocardiographic surveillance is recommended to detect early cardiac dysfunction and initiate medical therapy. Clinical anecdote suggests that echocardiographic quality diminishes over time, impeding accurate assessment of left ventricular systolic function. Furthermore, evidence-based guidelines for the use of cardiac imaging in DMD, including cardiac magnetic resonance imaging (CMR), are limited. The objective of our single-center, retrospective study was to quantify the deterioration in echocardiographic image quality with increasing patient age and identify an age at which CMR should be considered. We retrospectively reviewed and graded the image quality of serial echocardiograms obtained in young patients with DMD. The quality of 16 left ventricular segments in two echocardiographic views was visually graded using a binary scoring system. An endocardial border delineation percentage (EBDP) score was calculated by dividing the number of segments with adequate endocardial delineation in each imaging window by the total number of segments present in that window and multiplying by 100. Linear regression analysis was performed to model the relationship between the EBDP scores and patient age. Fifty-five echocardiograms from 13 patients (mean age 11.6 years, range 3.6-19.9) were systematically reviewed. By 13 years of age, 50% of the echocardiograms were classified as suboptimal with ≥30% of segments inadequately visualized, and by 15 years of age, 78% of studies were suboptimal. Linear regression analysis revealed a negative correlation between patient age and EBDP score ( r  = -2.49, 95% confidence intervals -4.73, -0.25; p  = 0.032), with the score decreasing by 2.5% for each 1 year increase in age. Echocardiographic image quality declines with increasing age in DMD. Alternate

  9. 3D shape measurement using deterministic phase retrieval and a partially developed speckle field

    DEFF Research Database (Denmark)

    Almoro, Percival F.; Waller, Laura; Agour, Mostafa

    2012-01-01

    Fourier domain. The local variations of the recorded speckle patterns and the defocus distance approximate the axial intensity derivative which, in turn, is required to recover the wavefront phase via the transport of intensity equation (TIE). The SLM setup reduces the speckle recording time and the TIE...

  10. Software phantom with realistic speckle modeling for validation of image analysis methods in echocardiography

    Science.gov (United States)

    Law, Yuen C.; Tenbrinck, Daniel; Jiang, Xiaoyi; Kuhlen, Torsten

    2014-03-01

    Computer-assisted processing and interpretation of medical ultrasound images is one of the most challenging tasks within image analysis. Physical phenomena in ultrasonographic images, e.g., the characteristic speckle noise and shadowing effects, make the majority of standard methods from image analysis non optimal. Furthermore, validation of adapted computer vision methods proves to be difficult due to missing ground truth information. There is no widely accepted software phantom in the community and existing software phantoms are not exible enough to support the use of specific speckle models for different tissue types, e.g., muscle and fat tissue. In this work we propose an anatomical software phantom with a realistic speckle pattern simulation to _ll this gap and provide a exible tool for validation purposes in medical ultrasound image analysis. We discuss the generation of speckle patterns and perform statistical analysis of the simulated textures to obtain quantitative measures of the realism and accuracy regarding the resulting textures.

  11. Phase conjugation of speckle-inhomogeneous radiation in a holographic Nd:YAG laser with a short thermal hologram

    International Nuclear Information System (INIS)

    Yarovoi, V V; Kirsanov, A V

    2002-01-01

    A model of the so-called short hologram, which does not exhibit in-depth diffraction deformation of the fine speckle pattern of the recording fields, is studied. The investigation is performed by the example of a thermal hologram recorded by two speckle waves, which is the output mirror of a ring laser produced as a result of this recording. It is shown that the ability of this short hologram to select a wave conjugated to a speckle signal in the mode of the holographic laser depends both on the degree of mutual mixing of the speckles of recording beams in the hologram volume and on the effects of its saturation by the beams. The maximum accuracy of phase conjugation of speckle radiation in the holographic Nd:YAG laser achieved upon the best selection of the conjugate wave by the short thermal hologram was 93%. (nonlinear optical phenomena)

  12. Intrinsic speckle noise in in-line particle holography due to polydisperse and continuous particle sizes

    Science.gov (United States)

    Edwards, Philip J.; Hobson, Peter R.; Rodgers, G. J.

    2000-08-01

    In-line particle holography is subject to image deterioration due to intrinsic speckle noise. The resulting reduction in the signal to noise ratio (SNR) of the replayed image can become critical for applications such as holographic particle velocimetry (HPV) and 3D visualisation of marine plankton. Work has been done to extend the mono-disperse model relevant to HPV to include poly-disperse particle fields appropriate for the visualisation of marine plankton. Continuous and discrete particle fields are both considered. It is found that random walk statistics still apply for the poly-disperse case. The speckle field is simply the summation of the individual speckle patters due to each scatter size. Therefor the characteristic speckle parameter (which encompasses particle diameter, concentration and sample depth) is alos just the summation of the individual speckle parameters. This reduces the SNR calculation to the same form as for the mono-disperse case. For the continuous situation three distributions, power, exponential and Gaussian are discussed with the resulting SNR calcuated. The work presented here was performed as part of the Holomar project to produce a working underwater holographic camera for recording plankton.

  13. MATLAB for laser speckle contrast analysis (LASCA): a practice-based approach

    Science.gov (United States)

    Postnikov, Eugene B.; Tsoy, Maria O.; Postnov, Dmitry E.

    2018-04-01

    Laser Speckle Contrast Analysis (LASCA) is one of the most powerful modern methods for revealing blood dynamics. The experimental design and theory for this method are well established, and the computational recipie is often regarded to be trivial. However, the achieved performance and spatial resolution may considerable differ for different implementations. We comprise a minireview of known approaches to the spatial laser speckle contrast data processing and their realization in MATLAB code providing an explicit correspondence to the mathematical representation, a discussion of available implementations. We also present the algorithm based on the 2D Haar wavelet transform, also supplied with the program code. This new method provides an opportunity to introduce horizontal, vertical and diagonal speckle contrasts; it may be used for processing highly anisotropic images of vascular trees. We provide the comparative analysis of the accuracy of vascular pattern detection and the processing times with a special attention to details of the used MATLAB procedures.

  14. Speckle Reduction and Structure Enhancement by Multichannel Median Boosted Anisotropic Diffusion

    Directory of Open Access Journals (Sweden)

    Yang Zhi

    2004-01-01

    Full Text Available We propose a new approach to reduce speckle noise and enhance structures in speckle-corrupted images. It utilizes a median-anisotropic diffusion compound scheme. The median-filter-based reaction term acts as a guided energy source to boost the structures in the image being processed. In addition, it regularizes the diffusion equation to ensure the existence and uniqueness of a solution. We also introduce a decimation and back reconstruction scheme to further enhance the processing result. Before the iteration of the diffusion process, the image is decimated and a subpixel shifted image set is formed. This allows a multichannel parallel diffusion iteration, and more importantly, the speckle noise is broken into impulsive or salt-pepper noise, which is easy to remove by median filtering. The advantage of the proposed technique is clear when it is compared to other diffusion algorithms and the well-known adaptive weighted median filtering (AWMF scheme in both simulation and real medical ultrasound images.

  15. Laser speckle technology in stomatology. diagnostics of stresses and strains of hard biotissues and orthodontic and orthopedic structures

    Science.gov (United States)

    Denisova, Yu. L.; Bazylev, N. B.; Rubnikovich, S. P.; Fomin, N. A.

    2013-07-01

    We have investigated the formation and dynamics of speckle biofi elds formed by hard biotissues of the oral cavity irradiated with low-intensity radiation. We present experimental methods for diagnosing the stressed-strained state of the maxillodental system and orthodontic and orthopedic structures based on speckle technologies and crosscorrelation analysis of speckle biofi elds.

  16. Optical design of the comet Shoemaker-Levy speckle camera

    Energy Technology Data Exchange (ETDEWEB)

    Bissinger, H. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    An optical design is presented in which the Lick 3 meter telescope and a bare CCD speckle camera system was used to image the collision sites of the Shoemaker-Levy 9 comet with the Planet Jupiter. The brief overview includes of the optical constraints and system layout. The choice of a Risley prism combination to compensate for the time dependent atmospheric chromatic changes are described. Plate scale and signal-to-noise ratio curves resulting from imaging reference stars are compared with theory. Comparisons between un-corrected and reconstructed images of Jupiter`s impact sites. The results confirm that speckle imaging techniques can be used over an extended time period to provide a method to image large extended objects.

  17. Speckle suppression via sparse representation for wide-field imaging through turbid media.

    Science.gov (United States)

    Jang, Hwanchol; Yoon, Changhyeong; Chung, Euiheon; Choi, Wonshik; Lee, Heung-No

    2014-06-30

    Speckle suppression is one of the most important tasks in the image transmission through turbid media. Insufficient speckle suppression requires an additional procedure such as temporal ensemble averaging over multiple exposures. In this paper, we consider the image recovery process based on the so-called transmission matrix (TM) of turbid media for the image transmission through the media. We show that the speckle left unremoved in the TM-based image recovery can be suppressed effectively via sparse representation (SR). SR is a relatively new signal reconstruction framework which works well even for ill-conditioned problems. This is the first study to show the benefit of using the SR as compared to the phase conjugation (PC) a de facto standard method to date for TM-based imaging through turbid media including a live cell through tissue slice.

  18. Speckle and fringe dynamics in imagingspeckle-pattern interferometry for spatial-filtering velocimetry

    DEFF Research Database (Denmark)

    Jakobsen, Michael Linde; Iversen, Theis F. Q.; Yura, Harold T.

    2011-01-01

    This paper analyzes the dynamics of laser speckles and fringes, formed in an imaging-speckle-pattern interferometer with the purpose of sensing linear three-dimensional motion and out-of-plane components of rotation in real time, using optical spatial-filtering-velocimetry techniques. The ensemble......-average definition of the cross-correlation function is applied to the intensity distributions, obtained in the observation plane at two positions of the object. The theoretical analysis provides a description for the dynamics of both the speckles and the fringes. The analysis reveals that both the magnitude...... and direction of all three linear displacement components of the object movement can be determined. Simultaneously, out-ofplane rotation of the object including the corresponding directions can be determined from the spatial gradient of the in-plane fringe motion throughout the observation plane. The theory...

  19. Differential expression of speckled POZ protein, SPOP: Putative ...

    Indian Academy of Sciences (India)

    2014-05-01

    May 1, 2014 ... In other mouse tissues and human cancer cell lines analysed, only low SPOP ... speckled POZ protein; SRC-3, steroid receptor co-activator-3; TNF, tumour necrosis factor; ...... complexity of primary human prostate cancer.

  20. Observations of binary stars by speckle interferometry

    International Nuclear Information System (INIS)

    Morgan, B.L.; Beckmann, G.K.; Scaddan, R.J.

    1980-01-01

    This is the second paper in a series describing observations of binary stars using the technique of speckle interferometry. Observations were made using the 2.5-m Isaac Newton Telescope and the 1-m telescope of the Royal Greenwich Observatory and the 1.9-m telescope of the South African Astronomical Observatory. The classical Rayleigh diffraction limits are 0.050 arcsec for the 2.5-m telescope, 0.065 arcsec for the 1.9-m telescope and 0.125 arcsec for the 1-m telescope, at a wavelength of 500 nm. The results of 29 measurements of 26 objects are presented. The objects include long period spectroscopic binaries from the 6th Catalogue of Batten, close visual binary systems from the 3rd Catalogue of Finsen and Worley and variable stars. Nine of the objects have not been previously resolved by speckle interferometry. New members are detected in the systems β Cep, p Vel and iota UMa. (author)

  1. Myocardial Deformation Measured by 3-Dimensional Speckle Tracking in Children and Adolescents With Systemic Arterial Hypertension.

    Science.gov (United States)

    Navarini, Susanne; Bellsham-Revell, Hannah; Chubb, Henry; Gu, Haotian; Sinha, Manish D; Simpson, John M

    2017-12-01

    Systemic arterial hypertension predisposes children to cardiovascular risk in childhood and adult life. Despite extensive study of left ventricular (LV) hypertrophy, detailed 3-dimensional strain analysis of cardiac function in hypertensive children has not been reported. The aim of this study was to evaluate LV mechanics (strain, twist, and torsion) in young patients with hypertension compared with a healthy control group and assess factors associated with functional measurements. Sixty-three patients (26 hypertension and 37 normotensive) were enrolled (mean age, 14.3 and 11.4 years; 54% men and 41% men, respectively). All children underwent clinical evaluation and echocardiographic examination, including 3-dimensional strain. There was no difference in LV volumes and ejection fraction between the groups. Myocardial deformation was significantly reduced in those with hypertension compared with controls. For hypertensive and normotensive groups, respectively, global longitudinal strain was -15.1±2.3 versus -18.5±1.9 ( P hypertensive and normotensive children, but children with hypertension had significantly lower strain indices. Whether reduced strain might predict future cardiovascular risk merits further longitudinal study. © 2017 American Heart Association, Inc.

  2. Speckle imaging of active galactic nuclei: NGC 1068 and NGC 4151

    International Nuclear Information System (INIS)

    Ebstein, S.M.

    1987-01-01

    High-resolution images of NGC 1068 and NGC 4151 in the [O III) 5007A line the nearby continuum produced from data taken with the PAPA photon-counting imaging detector using the technique of speckle imaging are presented. The images show an unresolved core of [O III] 5007A emission in the middle of an extended emission region. The extended emission tends to lie alongside the subarcsecond radio structure. In NGC 4151, the extended emission comes from a nearly linear structure extending on both sides of the unresolved core. In NGC 1068, the extended emission is also a linear structure centered on the unresolved core but the emission is concentrated in lobes lying to either side of the major axis. The continuum of NGC 4151 is spatially unresolved. The continuum of NGC 1068 is extended ∼1'' to the SW of the center of the [O III] 5007A emission. Certain aspects of the PAPA detector are discussed, including the variable-threshold discriminators that track the image intensifier pulse height and the camera artifacts. The data processing is described in detail

  3. Echocardiographic and clinical outcomes of central versus noncentral percutaneous edge-to-edge repair of degenerative mitral regurgitation

    DEFF Research Database (Denmark)

    Estévez-Loureiro, Rodrigo; Franzen, Olaf; Winter, Reidar

    2013-01-01

    This study aimed to assess the clinical and echocardiographic results of MitraClip implantation in noncentral degenerative mitral regurgitation (dMR) compared with central dMR.......This study aimed to assess the clinical and echocardiographic results of MitraClip implantation in noncentral degenerative mitral regurgitation (dMR) compared with central dMR....

  4. Robust Myocardial Motion Tracking for Echocardiography: Variational Framework Integrating Local-to-Global Deformation

    Directory of Open Access Journals (Sweden)

    Chi Young Ahn

    2013-01-01

    Full Text Available This paper proposes a robust real-time myocardial border tracking algorithm for echocardiography. Commonly, after an initial contour of LV border is traced at one or two frames from the entire cardiac cycle, LV contour tracking is performed over the remaining frames. Among a variety of tracking techniques, optical flow method is the most widely used for motion estimation of moving objects. However, when echocardiography data is heavily corrupted in some local regions, the errors bring the tracking point out of the endocardial border, resulting in distorted LV contours. This shape distortion often occurs in practice since the data acquisition is affected by ultrasound artifacts, dropouts, or shadowing phenomena of cardiac walls. The proposed method is designed to deal with this shape distortion problem by integrating local optical flow motion and global deformation into a variational framework. The proposed descent method controls the individual tracking points to follow the local motions of a specific speckle pattern, while their overall motions are confined to the global motion constraint being approximately an affine transform of the initial tracking points. Many real experiments show that the proposed method achieves better overall performance than conventional methods.

  5. Speckle correlation resolution enhancement of wide-field fluorescence imaging (Conference Presentation)

    Science.gov (United States)

    Yilmaz, Hasan

    2016-03-01

    Structured illumination enables high-resolution fluorescence imaging of nanostructures [1]. We demonstrate a new high-resolution fluorescence imaging method that uses a scattering layer with a high-index substrate as a solid immersion lens [2]. Random scattering of coherent light enables a speckle pattern with a very fine structure that illuminates the fluorescent nanospheres on the back surface of the high-index substrate. The speckle pattern is raster-scanned over the fluorescent nanospheres using a speckle correlation effect known as the optical memory effect. A series of standard-resolution fluorescence images per each speckle pattern displacement are recorded by an electron-multiplying CCD camera using a commercial microscope objective. We have developed a new phase-retrieval algorithm to reconstruct a high-resolution, wide-field image from several standard-resolution wide-field images. We have introduced phase information of Fourier components of standard-resolution images as a new constraint in our algorithm which discards ambiguities therefore ensures convergence to a unique solution. We demonstrate two-dimensional fluorescence images of a collection of nanospheres with a deconvolved Abbe resolution of 116 nm and a field of view of 10 µm × 10 µm. Our method is robust against optical aberrations and stage drifts, therefore excellent for imaging nanostructures under ambient conditions. [1] M. G. L. Gustafsson, J. Microsc. 198, 82-87 (2000). [2] H. Yilmaz, E. G. van Putten, J. Bertolotti, A. Lagendijk, W. L. Vos, and A. P. Mosk, Optica 2, 424-429 (2015).

  6. Speckle photography applied to measure deformations of very large structures

    Science.gov (United States)

    Conley, Edgar; Morgan, Chris K.

    1995-04-01

    Fundamental principles of mechanics have recently been brought to bear on problems concerning very large structures. Fields of study include tectonic plate motion, nuclear waste repository vault closure mechanisms, the flow of glacier and sea ice, and highway bridge damage assessment and residual life prediction. Quantitative observations, appropriate for formulating and verifying models, are still scarce however, so the need to adapt new methods of experimental mechanics is clear. Large dynamic systems often exist in environments subject to rapid change. Therefore, a simple field technique that incorporates short time scales and short gage lengths is required. Further, the measuring methods must yield displacements reliably, and under oft-times adverse field conditions. Fortunately, the advantages conferred by an experimental mechanics technique known as speckle photography nicely fulfill this rather stringent set of performance requirements. Speckle seemed to lend itself nicely to the application since it is robust and relatively inexpensive. Experiment requirements are minimal -- a camera, high resolution film, illumination, and an optically rough surface. Perhaps most important is speckle's distinct advantage over point-by-point methods: It maps the two dimensional displacement vectors of the whole field of interest. And finally, given the method's high spatial resolution, relatively short observation times are necessary. In this paper we discuss speckle, two variations of which were used to gage the deformation of a reinforced concrete bridge structure subjected to bending loads. The measurement technique proved to be easily applied, and yielded the location of the neutral axis self consistently. The research demonstrates the feasibility of using whole field techniques to detect and quantify surface strains of large structures under load.

  7. The impact of left ventricular deformation and dyssynchrony on improvement of left ventricular ejection fraction following radiofrequency catheter ablation in Wolff-Parkinson-White syndrome: A comprehensive study by speckle tracking echocardiography.

    Science.gov (United States)

    Nagai, Tomoo; Hamabe, Akira; Arakawa, Junko; Tabata, Hirotsugu; Nishioka, Toshihiko

    2017-11-01

    The purpose of this study was to evaluate left ventricular (LV) deformation and LV dyssynchrony in patients with Wolff-Parkinson-White (WPW) syndrome and to identify the factors that affect the efficacy of radiofrequency catheter ablation (RFCA). Thirty patients (26 men, mean age 40 ± 12 years) with WPW syndrome were prospectively recruited for this study. They underwent 2-dimensional transthoracic echocardiography with speckle tracking analysis before RFCA and again within 48 hours after RFCA. Control group consisted of 15 age and sex-matched healthy volunteers. The patients had significantly lower LV ejection fraction (LVEF), global longitudinal strain (S l ), and global circumferential strain (S c ) compared with healthy controls (64% ± 8% vs 68% ± 5%, P = .049; -17.6% ± 3.2% vs -19.9% ± 3.3%, P = .037, -15.2% ± 2.5% vs -19.4% ± 2.5%, P syndrome, impaired LV circumferential deformation can be restored by RFCA with concomitant improvement in LV dyssynchrony and LVEF. © 2017, Wiley Periodicals, Inc.

  8. Acousto-electrical speckle pattern in Lorentz force electrical impedance tomography

    International Nuclear Information System (INIS)

    Grasland-Mongrain, Pol; Destrempes, François; Cloutier, Guy; Mari, Jean-Martial; Souchon, Rémi; Catheline, Stefan; Chapelon, Jean-Yves; Lafon, Cyril

    2015-01-01

    Ultrasound speckle is a granular texture pattern appearing in ultrasound imaging. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasound-based medical imaging technique of the tissue electrical conductivity. It is based on the application of an ultrasound wave in a medium placed in a magnetic field and on the measurement of the induced electric current due to Lorentz force. Similarly to ultrasound imaging, we hypothesized that a speckle could be observed with Lorentz force electrical impedance tomography imaging. In this study, we first assessed the theoretical similarity between the measured signals in Lorentz force electrical impedance tomography and in ultrasound imaging modalities. We then compared experimentally the signal measured in both methods using an acoustic and electrical impedance interface. Finally, a bovine muscle sample was imaged using the two methods. Similar speckle patterns were observed. This indicates the existence of an ‘acousto-electrical speckle’ in the Lorentz force electrical impedance tomography with spatial characteristics driven by the acoustic parameters but due to electrical impedance inhomogeneities instead of acoustic ones as is the case of ultrasound imaging. (paper)

  9. Acousto-electrical speckle pattern in Lorentz force electrical impedance tomography

    Science.gov (United States)

    Grasland-Mongrain, Pol; Destrempes, François; Mari, Jean-Martial; Souchon, Rémi; Catheline, Stefan; Chapelon, Jean-Yves; Lafon, Cyril; Cloutier, Guy

    2015-05-01

    Ultrasound speckle is a granular texture pattern appearing in ultrasound imaging. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasound-based medical imaging technique of the tissue electrical conductivity. It is based on the application of an ultrasound wave in a medium placed in a magnetic field and on the measurement of the induced electric current due to Lorentz force. Similarly to ultrasound imaging, we hypothesized that a speckle could be observed with Lorentz force electrical impedance tomography imaging. In this study, we first assessed the theoretical similarity between the measured signals in Lorentz force electrical impedance tomography and in ultrasound imaging modalities. We then compared experimentally the signal measured in both methods using an acoustic and electrical impedance interface. Finally, a bovine muscle sample was imaged using the two methods. Similar speckle patterns were observed. This indicates the existence of an ‘acousto-electrical speckle’ in the Lorentz force electrical impedance tomography with spatial characteristics driven by the acoustic parameters but due to electrical impedance inhomogeneities instead of acoustic ones as is the case of ultrasound imaging.

  10. Quantitative X-ray dark-field and phase tomography using single directional speckle scanning technique

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hongchang, E-mail: hongchang.wang@diamond.ac.uk; Kashyap, Yogesh; Sawhney, Kawal [Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE (United Kingdom)

    2016-03-21

    X-ray dark-field contrast tomography can provide important supplementary information inside a sample to the conventional absorption tomography. Recently, the X-ray speckle based technique has been proposed to provide qualitative two-dimensional dark-field imaging with a simple experimental arrangement. In this letter, we deduce a relationship between the second moment of scattering angle distribution and cross-correlation degradation of speckle and establish a quantitative basis of X-ray dark-field tomography using single directional speckle scanning technique. In addition, the phase contrast images can be simultaneously retrieved permitting tomographic reconstruction, which yields enhanced contrast in weakly absorbing materials. Such complementary tomography technique can allow systematic investigation of complex samples containing both soft and hard materials.

  11. A new method to estimate left ventricular circumferential midwall systolic function by standard echocardiography: Concordance between models and validation by speckle tracking.

    Science.gov (United States)

    Ballo, Piercarlo; Nistri, Stefano; Bocelli, Arianna; Mele, Donato; Dini, Frank L; Galderisi, Maurizio; Zuppiroli, Alfredo; Mondillo, Sergio

    2016-01-15

    Assessment of left ventricular circumferential (LVcirc) systolic function by standard echocardiography can be performed by estimating midwall fractional shortening (mFS) and stress-corrected mFS (ScmFS). Their determination is based on spherical or cylindrical LV geometric models, which often yield discrepant values. We developed a new model based on a more realistic truncated ellipsoid (TE) LV shape, and explored the concordance between models among hypertensive patients. We also compared the relationships of different mFS and ScmFS estimates with indexes of LVcirc systolic strain. In 364 hypertensive subjects, mFS was determined using the spherical (mFSspher), cylindrical (mFScyl), and TE model (mFSTE). Corresponding values of ScmFSspher, ScmFScyl, and ScmFSTE were obtained. Global circumferential strain (GCS) and systolic strain rate (GCSR) were also measured by speckle tracking. The three models showed poor concordance for the estimation of mFS, with average differences ranging between 11% and 30% and wide limits of agreement. Similar results were found for ScmFS, where reclassification rates for the identification of abnormal LVcirc systolic function ranged between 18% and 29%. When tested against strain indexes, mFSTE and ScmFSTE showed the best correlations (R=0.81 and R=0.51, p<0.0001 for both) with GCS and GCSR. Multivariable analysis confirmed that mFSTE and ScmFSTE showed the strongest independent associations with LVcirc strain measures. Substantial discrepancies in LVcirc midwall systolic indexes exist between different models, supporting the need of model-specific normative data. The use of the TE model might provide indexes that show the best associations with established strain measures of LVcirc systolic function. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Detection of fungi colony growth on bones by dynamic speckle

    Science.gov (United States)

    Vincitorio, F. M.; Budini, N.; Mulone, C.; Spector, M.; Freyre, C.; López Díaz, A. J.; Ramil, A.

    2013-11-01

    In this work we have studied the dynamic speckle patterns of mucor fungi colonies, which were inoculated on different samples. We were interested in analyzing the development of fungi colonies in bones, since during the last two years, a series of infections by mucor fungi have been reported on patients from different hospitals in Argentina. Coincidentally, all of these infections appeared on patients that were subjected to a surgical intervention for implantation of a titanium prosthesis. Apparently, the reason of the infection was a deficient sterilization process in conjunction with an accidental contamination. We observed that fungi growth, activity and death can be distinguished by means of the dynamic speckle technique.

  13. Echocardiography and cardiac resynchronisation therapy, friends or foes?

    Science.gov (United States)

    van Everdingen, W M; Schipper, J C; van 't Sant, J; Ramdat Misier, K; Meine, M; Cramer, M J

    2016-01-01

    Echocardiography is used in cardiac resynchronisation therapy (CRT) to assess cardiac function, and in particular left ventricular (LV) volumetric status, and prediction of response. Despite its widespread applicability, LV volumes determined by echocardiography have inherent measurement errors, interobserver and intraobserver variability, and discrepancies with the gold standard magnetic resonance imaging. Echocardiographic predictors of CRT response are based on mechanical dyssynchrony. However, parameters are mainly tested in single-centre studies or lack feasibility. Speckle tracking echocardiography can guide LV lead placement, improving volumetric response and clinical outcome by guiding lead positioning towards the latest contracting segment. Results on optimisation of CRT device settings using echocardiographic indices have so far been rather disappointing, as results suffer from noise. Defining response by echocardiography seems valid, although re-assessment after 6 months is advisable, as patients can show both continuous improvement as well as deterioration after the initial response. Three-dimensional echocardiography is interesting for future implications, as it can determine volume, dyssynchrony and viability in a single recording, although image quality needs to be adequate. Deformation patterns from the septum and the derived parameters are promising, although validation in a multicentre trial is required. We conclude that echocardiography has a pivotal role in CRT, although clinicians should know its shortcomings.

  14. Hypertonic-induced lamin A/C synthesis and distribution to nucleoplasmic speckles is mediated by TonEBP/NFAT5 transcriptional activator

    International Nuclear Information System (INIS)

    Favale, Nicolas O.; Sterin Speziale, Norma B.; Fernandez Tome, Maria C.

    2007-01-01

    Lamin A/C is the most studied nucleoskeletal constituent. Lamin A/C expression indicates cell differentiation and is also a structural component of nuclear speckles, which are involved in gene expression regulation. Hypertonicity has been reported to induce renal epithelial cell differentiation and expression of TonEBP (NFAT5), a transcriptional activator of hypertonicity-induced gene transcription. In this paper, we investigate the effect of hypertonicity on lamin A/C expression in MDCK cells and the involvement of TonEBP. Hypertonicity increased lamin A/C expression and its distribution to nucleoplasm with speckled pattern. Microscopy showed codistribution of TonEBP and lamin A/C in nucleoplasmic speckles, and immunoprecipitation demonstrated their interaction. TonEBP silencing caused lamin A/C redistribution from nucleoplasmic speckles to the nuclear rim, followed by lamin decrease, thus showing that hypertonicity induces lamin A/C speckles through a TonEBP-dependent mechanism. We suggest that lamin A/C speckles could serve TonEBP as scaffold thus favoring its role in hypertonicity

  15. SPECKLE CAMERA OBSERVATIONS FOR THE NASA KEPLER MISSION FOLLOW-UP PROGRAM

    International Nuclear Information System (INIS)

    Howell, Steve B.; Everett, Mark E.; Sherry, William; Horch, Elliott; Ciardi, David R.

    2011-01-01

    We present the first results from a speckle imaging survey of stars classified as candidate exoplanet host stars discovered by the Kepler mission. We use speckle imaging to search for faint companions or closely aligned background stars that could contribute flux to the Kepler light curves of their brighter neighbors. Background stars are expected to contribute significantly to the pool of false positive candidate transiting exoplanets discovered by the Kepler mission, especially in the case that the faint neighbors are eclipsing binary stars. Here, we describe our Kepler follow-up observing program, the speckle imaging camera used, our data reduction, and astrometric and photometric performance. Kepler stars range from R = 8 to 16 and our observations attempt to provide background non-detection limits 5-6 mag fainter and binary separations of ∼0.05-2.0 arcsec. We present data describing the relative brightness, separation, and position angles for secondary sources, as well as relative plate limits for non-detection of faint nearby stars around each of 156 target stars. Faint neighbors were found near 10 of the stars.

  16. Holographic interferometry and laser speckle photography as aids to assessment of pressurized components

    International Nuclear Information System (INIS)

    Martin, D.J.V.

    1975-01-01

    This paper gives details of the defect detection holographic technique and describes laser speckle photography to evaluate in phase movement and strain in pressurized components. The new fibre optic technique and system appraisal is included. The holographic tests show that it is possible to detect on the outside of tubes defects in the bore approximately 10% of thickness deep. Speckle photography gives object lateral movement, direction and strain. (Auth.)

  17. Echocardiographic reference ranges for sedentary donkeys in the UK.

    Science.gov (United States)

    Roberts, S L; Dukes-McEwan, J

    2016-10-01

    The aim of this study was to provide two-dimensional (2D) and M-mode echocardiographic reference ranges from a sample of the UK population of donkeys including geriatrics (>30 years), owned by The Donkey Sanctuary, and to assess the influence of gender, weight and age on these variables. A total of 36 donkeys with no clinical or echocardiographic evidence of cardiovascular disease were examined; 24 geldings and 12 females, aged 3-45 years old, weighing 130-262 kg. Left atrial to aortic ratio was larger in geldings (P=0.004). There was no significant difference for left ventricular M-mode diastolic diameter between females and geldings (P=0.121) after exclusion of one heavy female outlier. 2D measurements significantly increased with bodyweight including maximal left atrial diameter (R(2)=0.112; P=0.046), aortic diameter at various levels (e.g. annulus: R(2)=0.35; Pdonkeys across a wide age range and shows differences compared with reference ranges from working donkeys. British Veterinary Association.

  18. Echocardiographic evaluation of the right heart.

    Science.gov (United States)

    Schneider, Matthias; Binder, Thomas

    2018-03-19

    Symptoms of right ventricular failure include dyspnea, a reduction in exercise capacity, and fluid retention. Right ventricular (dys)function strongly influences functional state and survival. The right ventricle is directly involved in a variety of diseases. A thorough analysis of right ventricular size and function, as well as estimation of pulmonary artery pressures is an important part of every echocardiographic examination. This review analyses the most commonly used parameters for quantification of right ventricular function. It gives a practical approach for estimation of right ventricular size and function, as well as pulmonary artery pressure.

  19. Analysis of Minute Features in Speckled Imagery with Maximum Likelihood Estimation

    Directory of Open Access Journals (Sweden)

    Alejandro C. Frery

    2004-12-01

    Full Text Available This paper deals with numerical problems arising when performing maximum likelihood parameter estimation in speckled imagery using small samples. The noise that appears in images obtained with coherent illumination, as is the case of sonar, laser, ultrasound-B, and synthetic aperture radar, is called speckle, and it can neither be assumed Gaussian nor additive. The properties of speckle noise are well described by the multiplicative model, a statistical framework from which stem several important distributions. Amongst these distributions, one is regarded as the universal model for speckled data, namely, the 𝒢0 law. This paper deals with amplitude data, so the 𝒢A0 distribution will be used. The literature reports that techniques for obtaining estimates (maximum likelihood, based on moments and on order statistics of the parameters of the 𝒢A0 distribution require samples of hundreds, even thousands, of observations in order to obtain sensible values. This is verified for maximum likelihood estimation, and a proposal based on alternate optimization is made to alleviate this situation. The proposal is assessed with real and simulated data, showing that the convergence problems are no longer present. A Monte Carlo experiment is devised to estimate the quality of maximum likelihood estimators in small samples, and real data is successfully analyzed with the proposed alternated procedure. Stylized empirical influence functions are computed and used to choose a strategy for computing maximum likelihood estimates that is resistant to outliers.

  20. Noise reduction in digital speckle pattern interferometry using bidimensional empirical mode decomposition

    International Nuclear Information System (INIS)

    Bernini, Maria Belen; Federico, Alejandro; Kaufmann, Guillermo H.

    2008-01-01

    We propose a bidimensional empirical mode decomposition (BEMD) method to reduce speckle noise in digital speckle pattern interferometry (DSPI) fringes. The BEMD method is based on a sifting process that decomposes the DSPI fringes in a finite set of subimages represented by high and low frequency oscillations, which are named modes. The sifting process assigns the high frequency information to the first modes, so that it is possible to discriminate speckle noise from fringe information, which is contained in the remaining modes. The proposed method is a fully data-driven technique, therefore neither fixed basis functions nor operator intervention are required. The performance of the BEMD method to denoise DSPI fringes is analyzed using computer-simulated data, and the results are also compared with those obtained by means of a previously developed one-dimensional empirical mode decomposition approach. An application of the proposed BEMD method to denoise experimental fringes is also presented

  1. Non-moving Hadamard matrix diffusers for speckle reduction in laser pico-projectors

    Science.gov (United States)

    Thomas, Weston; Middlebrook, Christopher

    2014-12-01

    Personal electronic devices such as cell phones and tablets continue to decrease in size while the number of features and add-ons keep increasing. One particular feature of great interest is an integrated projector system. Laser pico-projectors have been considered, but the technology has not been developed enough to warrant integration. With new advancements in diode technology and MEMS devices, laser-based projection is currently being advanced for pico-projectors. A primary problem encountered when using a pico-projector is coherent interference known as speckle. Laser speckle can lead to eye irritation and headaches after prolonged viewing. Diffractive optical elements known as diffusers have been examined as a means to lower speckle contrast. This paper presents a binary diffuser known as a Hadamard matrix diffuser. Using two static in-line Hadamard diffusers eliminates the need for rotation or vibration of the diffuser for temporal averaging. Two Hadamard diffusers were fabricated and contrast values measured showing good agreement with theory and simulated values.

  2. Three Dimensional Speckle Imaging Employing a Frequency-Locked Tunable Diode Laser

    Energy Technology Data Exchange (ETDEWEB)

    Cannon, Bret D.; Bernacki, Bruce E.; Schiffern, John T.; Mendoza, Albert

    2015-09-01

    We describe a high accuracy frequency stepping method for a tunable diode laser to improve a three dimensional (3D) imaging approach based upon interferometric speckle imaging. The approach, modeled after Takeda, exploits tuning an illumination laser in frequency as speckle interferograms of the object (specklegrams) are acquired at each frequency in a Michelson interferometer. The resulting 3D hypercube of specklegrams encode spatial information in the x-y plane of each image with laser tuning arrayed along its z-axis. We present laboratory data of before and after results showing enhanced 3D imaging resulting from precise laser frequency control.

  3. Echocardiographic diagnosis of rare pathological patterns of sinus of Valsalva aneurysm.

    Directory of Open Access Journals (Sweden)

    Yali Yang

    Full Text Available To evaluate the value and improve the diagnostic accuracy of echocardiography in the diagnosis of a sinus of Valsalva aneurysm (SVA with rare pathological patterns.Echocardiographic features and surgical findings from 270 Chinese patients with SVA treated in the last 18 years (1995-2013 at the Union Hospital were compared retrospectively; 22 of 270 cases had rare patterns.The patients with SVA, a rare origin, a rare extending position, or a rare course accounted for 3.4%, 7.4%, and 0.4% of the 270 cases, respectively. The three most common aneurysmal complications of the patients with rare patterns were severe aortic regurgitation (16, obstruction of the ventricular outflow tract or valvular orifice (3, and conduction disturbance (3. The origin, course, extending position and rupture status of the SVAs determined by echocardiography were entirely consistent with surgical findings in 81.8% of the 22 cases. With the exception of one failed diagnosis of an aneurysmal wall dissection and one misdiagnosis of a descending aortic dissection, the echocardiographic results of SVA complications and associated cardiovascular lesions were also confirmed.We could accurately diagnose SVAs with rare pathological patterns by echocardiographic identification of distinguishing features. However, for several conditions, we could not accurately identify the origin or course of the aneurysm or define its relationship to adjacent structures using conventional echocardiography alone. Therefore, we recommend combining conventional echocardiography with different imaging techniques, such as transesophageal echocardiography, three-dimensional echocardiography, computed tomography angiography, and aortic angiography.

  4. Echocardiographic findings in haemodialysis patients according to their state of hydration.

    Science.gov (United States)

    Cristina Di Gioia, María; Gascuena, Raul; Gallar, Paloma; Cobo, Gabriela; Camacho, Rosa; Acosta, Nuria; Baranyi, Zsofia; Rodriguez, Isabel; Oliet, Aniana; Ortega, Olimpia; Fernandez, Inmaculada; Mon, Carmen; Ortiz, Milagros; Manzano, Mari C; Herrero, Juan C; Martinez, José I; Palma, Joaquín; Vigil, Ana

    Chronic fluid overload is frequent in hemodialysis patients (P) and it associates with hypertension, left ventricular hypertrophy (LVH) and higher mortality. Moreover, echocardiographic data assessing fluid overload is limited. Our aim was to evaluate the relationship between fluid overload measured by bioimpedance spectroscopy (BIS) and different echocardiographic parameters. Cross-sectional observational study including 76 stable patients. Dry weight was clinically assessed. BIS and echocardiography were performed. Weekly time-averaged fluid overload (TAFO) and relative fluid overload (FO/ECW) were calculated using BIS measurements. Based on TAFO three groups were defined: A- dehydrated, TAFO 1.5 l: 18 (24%). We found significant correlation between TAFO and left atrial volume index (LAVI) (r: 0.29; p=0.013) but not with FO/ECW (r 0.06; p=0.61). TAFO, but not FO/ECW kept a significant relationship with LAVI (p=0.03) using One-Way ANOVA test and linear regression methods. LVH was present in 73.7% (concentric 63.2%, eccentric in 10.5%). No differences between groups in the presence of LVH or left ventricular mass index were found. We found that left atrial volume index determined by echocardiographic Area-length method, but not left ventricle hypertrophy or dimensions of cavities, are related on hydration status based on bioimpedance measured time-averaged fluid overload (TAFO), and not with FO/ECW. Copyright © 2016 Sociedad Española de Nefrología. Published by Elsevier España, S.L.U. All rights reserved.

  5. In-vivo brain blood flow imaging based on laser speckle contrast imaging and synchrotron radiation microangiography

    International Nuclear Information System (INIS)

    Miao, Peng; Feng, Shihan; Zhang, Qi; Lin, Xiaojie; Xie, Bohua; Liu, Chenwei; Yang, Guo-Yuan

    2014-01-01

    Abstract In-vivo imaging of blood flow in the cortex and sub-cortex is still a challenge in biological and pathological studies of cerebral vascular diseases. Laser speckle contrast imaging (LSCI) only provides cortex blood flow information. Traditional synchrotron radiation micro-angiography (SRA) provides sub-cortical vasculature information with high resolution. In this study, a bolus front-tracking method was developed to extract blood flow information based on SRA. Combining LSCI and SRA, arterial blood flow in the ipsilateral cortex and sub-cortex was monitored after experimental intracerebral hemorrhage of mice. At 72 h after injury, a significant blood flow increase was observed in the lenticulostriate artery along with blood flow decrease in cortical branches of the middle cerebral artery. This combined strategy provides a new approach for the investigation of brain vasculature and blood flow changes in preclinical studies. (paper)

  6. Singular trajectories: space-time domain topology of developing speckle fields

    Science.gov (United States)

    Vasil'ev, Vasiliy; Soskin, Marat S.

    2010-02-01

    It is shown the space-time dynamics of optical singularities is fully described by singularities trajectories in space-time domain, or evolution of transverse coordinates(x, y) in some fixed plane z0. The dynamics of generic developing speckle fields was realized experimentally by laser induced scattering in LiNbO3:Fe photorefractive crystal. The space-time trajectories of singularities can be divided topologically on two classes with essentially different scenario and duration. Some of them (direct topological reactions) consist from nucleation of singularities pair at some (x, y, z0, t) point, their movement and annihilation. They possess form of closed loops with relatively short time of existence. Another much more probable class of trajectories are chain topological reactions. Each of them consists from sequence of links, i.e. of singularities nucleation in various points (xi yi, ti) and following annihilation of both singularities in other space-time points with alien singularities of opposite topological indices. Their topology and properties are established. Chain topological reactions can stop on the borders of a developing speckle field or go to infinity. Examples of measured both types of topological reactions for optical vortices (polarization C points) in scalar (elliptically polarized) natural developing speckle fields are presented.

  7. A Cognitive Machine Learning Algorithm for Cardiac Imaging: A Pilot Study for Differentiating Constrictive Pericarditis from Restrictive Cardiomyopathy

    Science.gov (United States)

    Sengupta, Partho P.; Huang, Yen-Min; Bansal, Manish; Ashrafi, Ali; Fisher, Matt; Shameer, Khader; Gall, Walt; Dudley, Joel T

    2016-01-01

    Background Associating a patient’s profile with the memories of prototypical patients built through previous repeat clinical experience is a key process in clinical judgment. We hypothesized that a similar process using a cognitive computing tool would be well suited for learning and recalling multidimensional attributes of speckle tracking echocardiography (STE) data sets derived from patients with known constrictive pericarditis (CP) and restrictive cardiomyopathy (RCM). Methods and Results Clinical and echocardiographic data of 50 patients with CP and 44 with RCM were used for developing an associative memory classifier (AMC) based machine learning algorithm. The STE data was normalized in reference to 47 controls with no structural heart disease, and the diagnostic area under the receiver operating characteristic curve (AUC) of the AMC was evaluated for differentiating CP from RCM. Using only STE variables, AMC achieved a diagnostic AUC of 89·2%, which improved to 96·2% with addition of 4 echocardiographic variables. In comparison, the AUC of early diastolic mitral annular velocity and left ventricular longitudinal strain were 82.1% and 63·7%, respectively. Furthermore, AMC demonstrated greater accuracy and shorter learning curves than other machine learning approaches with accuracy asymptotically approaching 90% after a training fraction of 0·3 and remaining flat at higher training fractions. Conclusions This study demonstrates feasibility of a cognitive machine learning approach for learning and recalling patterns observed during echocardiographic evaluations. Incorporation of machine learning algorithms in cardiac imaging may aid standardized assessments and support the quality of interpretations, particularly for novice readers with limited experience. PMID:27266599

  8. Atrial Fibrillation Ablation in Systolic Dysfunction: Clinical and Echocardiographic Outcomes

    Directory of Open Access Journals (Sweden)

    Tasso Julio Lobo

    2015-01-01

    Full Text Available Background: Heart failure and atrial fibrillation (AF often coexist in a deleterious cycle. Objective: To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF ablation. Methods: Patients with ventricular systolic dysfunction [ejection fraction (EF <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class and echocardiographic (EF, left atrial diameter data were compared (McNemar test and t test before and after ablation. Results: 31 patients (6 women, 25 men, aged 37 to 77 years (mean, 59.8±10.6, underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%. During a mean follow-up of 20.3±17 months, 24 patients (77% were in sinus rhythm, 11 (35% being on amiodarone. Eight patients (26% underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures. Significant NYHA functional class improvement was observed (pre-ablation: 2.23±0.56; postablation: 1.13±0.35; p<0.0001. The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68%±6.02%, post: 59%±13.2%, p=0.0005 and a significant left atrial diameter reduction (pre: 46.61±7.3 mm; post: 43.59±6.6 mm; p=0.026. No major complications occurred. Conclusion: Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement.

  9. Impact of surgical correction of tetralogy of fallot on short-term right and left ventricular function as determined by 2-dimensional speckle tracking echocardiography

    Science.gov (United States)

    Li, Yuman; Wang, Xinfang; Lv, Qing; Wang, Jing; Yang, YaLi; He, Lin; Yuan, Li; Zhang, Li; Xie, Mingxing

    2016-01-01

    Abstract Right ventricular (RV) and left ventricular (LV) dysfunction is an important determinant of poor clinical status in repaired patients with tetralogy of Fallot (TOF). The purpose of our study is to assess the impact of surgical repair on short-term RV and LV function by 2-dimensional speckle tracking echocardiography (STE). Sixty-seven patients (median age 12 months) with TOF before and 6 months after repair and 35 healthy subjects were studied. The patients were divided into the younger (age at surgery ≤12 months) and older (age at surgery >12 months) subgroups. RV and LV global longitudinal systolic strain and strain rate (SR), and LV global circumferential and radial systolic strain and SR were measured by STE. After repair, RV longitudinal strain and SR increased in the younger patients, whereas RV longitudinal SR was decreased in the older patients. LV deformation parameters were unchanged in all patients. In the multivariate analysis, patients with better RV and LV deformation parameters preoperatively were identified to have better RV and LV strain and SR postoperatively (P < 0.05 for all). The surgical approach of the pulmonary valve ring was predictive of RV and LV systolic function postoperatively (P < 0.05 for all). After TOF repair, short-term RV function improvement is identified in the younger but not in the older patients, whereas LV function is unchanged in all patients. The preoperative RV and LV deformational indices are the determinant of postoperative biventricular function improvement. STE appears to be a valuable tool for assessment of biventricular function after congenital heart disease surgery. PMID:27495064

  10. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. I. INSTRUMENT DESCRIPTION AND FIRST RESULTS

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Veillette, Daniel R.; Shah, Sagar C.; O'Rielly, Grant V.; Baena Galle, Roberto; Van Altena, William F.

    2009-01-01

    First results of a new speckle imaging system, the Differential Speckle Survey Instrument, are reported. The instrument is designed to take speckle data in two filters simultaneously with two independent CCD imagers. This feature results in three advantages over other speckle cameras: (1) twice as many frames can be obtained in the same observation time which can increase the signal-to-noise ratio for astrometric measurements, (2) component colors can be derived from a single observation, and (3) the two colors give substantial leverage over atmospheric dispersion, allowing for subdiffraction-limited separations to be measured reliably. Fifty-four observations are reported from the first use of the instrument at the Wisconsin-Indiana-Yale-NOAO 3.5 m Telescope 9 The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories. in 2008 September, including seven components resolved for the first time. These observations are used to judge the basic capabilities of the instrument.

  11. Airplane wing deformation and flight flutter detection method by using three-dimensional speckle image correlation technology.

    Science.gov (United States)

    Wu, Jun; Yu, Zhijing; Wang, Tao; Zhuge, Jingchang; Ji, Yue; Xue, Bin

    2017-06-01

    Airplane wing deformation is an important element of aerodynamic characteristics, structure design, and fatigue analysis for aircraft manufacturing, as well as a main test content of certification regarding flutter for airplanes. This paper presents a novel real-time detection method for wing deformation and flight flutter detection by using three-dimensional speckle image correlation technology. Speckle patterns whose positions are determined through the vibration characteristic of the aircraft are coated on the wing; then the speckle patterns are imaged by CCD cameras which are mounted inside the aircraft cabin. In order to reduce the computation, a matching technique based on Geodetic Systems Incorporated coded points combined with the classical epipolar constraint is proposed, and a displacement vector map for the aircraft wing can be obtained through comparing the coordinates of speckle points before and after deformation. Finally, verification experiments containing static and dynamic tests by using an aircraft wing model demonstrate the accuracy and effectiveness of the proposed method.

  12. Integration of image exposure time into a modified laser speckle imaging method

    Energy Technology Data Exchange (ETDEWEB)

    RamIrez-San-Juan, J C; Salazar-Hermenegildo, N; Ramos-Garcia, R; Munoz-Lopez, J [Optics Department, INAOE, Puebla (Mexico); Huang, Y C [Department of Electrical Engineering and Computer Science, University of California, Irvine, CA (United States); Choi, B, E-mail: jcram@inaoep.m [Beckman Laser Institute and Medical Clinic, University of California, Irvine, CA (United States)

    2010-11-21

    Speckle-based methods have been developed to characterize tissue blood flow and perfusion. One such method, called modified laser speckle imaging (mLSI), enables computation of blood flow maps with relatively high spatial resolution. Although it is known that the sensitivity and noise in LSI measurements depend on image exposure time, a fundamental disadvantage of mLSI is that it does not take into account this parameter. In this work, we integrate the exposure time into the mLSI method and provide experimental support of our approach with measurements from an in vitro flow phantom.

  13. Integration of image exposure time into a modified laser speckle imaging method

    International Nuclear Information System (INIS)

    RamIrez-San-Juan, J C; Salazar-Hermenegildo, N; Ramos-Garcia, R; Munoz-Lopez, J; Huang, Y C; Choi, B

    2010-01-01

    Speckle-based methods have been developed to characterize tissue blood flow and perfusion. One such method, called modified laser speckle imaging (mLSI), enables computation of blood flow maps with relatively high spatial resolution. Although it is known that the sensitivity and noise in LSI measurements depend on image exposure time, a fundamental disadvantage of mLSI is that it does not take into account this parameter. In this work, we integrate the exposure time into the mLSI method and provide experimental support of our approach with measurements from an in vitro flow phantom.

  14. Demonstration of a Speckle Based Sensing with Pulse-Doppler Radar for Vibration Detection.

    Science.gov (United States)

    Ozana, Nisan; Bauer, Reuven; Ashkenazy, Koby; Sasson, Nissim; Schwarz, Ariel; Shemer, Amir; Zalevsky, Zeev

    2018-05-03

    In previous works, an optical technique for extraction and separation of remote static vibrations has been demonstrated. In this paper, we will describe an approach in which RF speckle movement is used to extract remote vibrations of a static target. The use of conventional radar Doppler methods is not suitable for detecting vibrations of static targets. In addition, the speckle method has an important advantage, in that it is able to detect vibrations at far greater distances than what is normally detected in classical optical methods. The experiment described in this paper was done using a motorized vehicle, which engine was turned on and off. The results showed that the system was able to distinguish between the different engine states, and in addition, was able to determine the vibration frequency of the engine. The first step towards real time detection of human vital signs using RF speckle patterns is presented.

  15. Clinical Outcome of Degenerative Mitral Regurgitation: Critical Importance of Echocardiographic Quantitative Assessment in Routine Practice.

    Science.gov (United States)

    Antoine, Clemence; Benfari, Giovanni; Michelena, Hector I; Malouf, Joseph F; Nkomo, Vuyisile T; Thapa, Prabin; Enriquez-Sarano, Maurice

    2018-05-31

    Background -Echocardiographic quantitation of degenerative mitral regurgitation (DMR) is recommended whenever possible in clinical guidelines but is criticized and its scalability to routine clinical practice doubted. We hypothesized that echocardiographic DMR quantitation, performed in routine clinical practice by multiple practitioners predicts independently long-term survival, and thus is essential to DMR management. Methods -We included patients diagnosed with isolated mitral-valve-prolapse 2003-2011 and any degree of MR quantified by any physician/sonographer in routine clinical practice. Clinical/echocardiographic data acquired at diagnosis were retrieved electronically. Endpoint was mortality under medical treatment analyzed by Kaplan-Meir method and Proportional-Hazard models. Results -The cohort included 3914 patients (55% male) aged 62±17 years, with left ventricular ejection fraction (LVEF) 63±8% and routinely measured effective regurgitant orifice area (EROA) 19[0-40] mm 2 During follow-up (6.7±3.1 years) 696 patients died under medical management and 1263 underwent mitral surgery. In multivariate analysis, routinely measured EROA was associated with mortality (adjusted-hazard-ratio 1.19[1.13-1.24] p 40 mm 2 threshold. Conclusions -Echocardiographic DMR quantitation is scalable to routine practice and is independently associated with clinical outcome. Routinely measured EROA is strongly associated with long-term survival under medical treatment. Excess mortality vs. the general population appears in the "moderate" DMR range and steadily increases with higher EROA. Hence, individual EROA values should be integrated into therapeutic considerations, additionally to categorical DMR grading.

  16. Selectivity and balance of spatial filtering velocimetry of objective speckles for measuring out-of-plane motion

    DEFF Research Database (Denmark)

    Jakobsen, Michael Linde; Yura, Hal T.; Hanson, Steen Grüner

    2015-01-01

    We probe the dynamics of objective laser speckles as the axial distance between the object and the observation plane changes. With the purpose of measuring out-of-plane motion in real time, we apply optical spatial filtering velocimetry to the speckle dynamics. To achieve this, a rotationally sym...

  17. Development of principles of two-cascaded laser speckle-microscopy with implication to high-precision express diagnostics of chlamydial infection

    Science.gov (United States)

    Ulianova, Onega; Moiseeva, Yulia; Filonova, Nadezhda; Subbotina, Irina; Zaitsev, Sergey; Saltykov, Yury; Polyanina, Tatiana; Lyapina, Anna; Ulyanov, Sergey; Larionova, Olga; Utz, Sergey; Feodorova, Valentina

    2018-04-01

    Principles of two-cascaded laser speckle-microscopy prospect for application to express diagnostics of chlamydial infection are developed. Prototype of two-cascaded speckle-microscope is designed and tested. Specific case of illumination of bacterial cells by dynamic speckles is considered. Express method of detection of epithelial cells, containing defects, which are caused by Chlamydia trachomatis bacteria, is suggested. Results of improved recognition of C. trachomatis bacteria are discussed.

  18. Echocardiographic findings in haemodialysis patients according to their state of hydration

    Directory of Open Access Journals (Sweden)

    María Cristina Di Gioia

    2017-01-01

    Conclusions: We found that left atrial volume index determined by echocardiographic Area-length method, but not left ventricle hypertrophy or dimensions of cavities, are related on hydration status based on bioimpedance measured time-averaged fluid overload (TAFO, and not with FO/ECW.

  19. Wavelet tree structure based speckle noise removal for optical coherence tomography

    Science.gov (United States)

    Yuan, Xin; Liu, Xuan; Liu, Yang

    2018-02-01

    We report a new speckle noise removal algorithm in optical coherence tomography (OCT). Though wavelet domain thresholding algorithms have demonstrated superior advantages in suppressing noise magnitude and preserving image sharpness in OCT, the wavelet tree structure has not been investigated in previous applications. In this work, we propose an adaptive wavelet thresholding algorithm via exploiting the tree structure in wavelet coefficients to remove the speckle noise in OCT images. The threshold for each wavelet band is adaptively selected following a special rule to retain the structure of the image across different wavelet layers. Our results demonstrate that the proposed algorithm outperforms conventional wavelet thresholding, with significant advantages in preserving image features.

  20. Sensitivity evaluation of dynamic speckle activity measurements using clustering methods

    International Nuclear Information System (INIS)

    Etchepareborda, Pablo; Federico, Alejandro; Kaufmann, Guillermo H.

    2010-01-01

    We evaluate and compare the use of competitive neural networks, self-organizing maps, the expectation-maximization algorithm, K-means, and fuzzy C-means techniques as partitional clustering methods, when the sensitivity of the activity measurement of dynamic speckle images needs to be improved. The temporal history of the acquired intensity generated by each pixel is analyzed in a wavelet decomposition framework, and it is shown that the mean energy of its corresponding wavelet coefficients provides a suited feature space for clustering purposes. The sensitivity obtained by using the evaluated clustering techniques is also compared with the well-known methods of Konishi-Fujii, weighted generalized differences, and wavelet entropy. The performance of the partitional clustering approach is evaluated using simulated dynamic speckle patterns and also experimental data.

  1. Measurement of deformation field in CT specimen using laser speckle

    International Nuclear Information System (INIS)

    Jeon, Moon Chang; Kang, Ki Ju

    2001-01-01

    To obtain A 2 experimentally in the J-A 2 theory, deformation field on the lateral surface of a CT specimen was to be determined using laser speckle method. The crack growth was measured using direct current potential drop method and most procedure of experimental and data reduction was performed according to ASTM Standard E1737-96. Laser speckle images during crack propagation were monitored by two CCD cameras to cancel the effect of rotation and translation of the specimen. An algorithm to pursue displacement of a point from each image was developed and successfully used to measure A 2 continuously as the crack tip was propagated. The effects of specimen thickness on J-R curve and A 2 were explored

  2. Application of laser speckle to randomized numerical linear algebra

    Science.gov (United States)

    Valley, George C.; Shaw, Thomas J.; Stapleton, Andrew D.; Scofield, Adam C.; Sefler, George A.; Johannson, Leif

    2018-02-01

    We propose and simulate integrated optical devices for accelerating numerical linear algebra (NLA) calculations. Data is modulated on chirped optical pulses and these propagate through a multimode waveguide where speckle provides the random projections needed for NLA dimensionality reduction.

  3. Effects of sedation on echocardiographic variables of left atrial and left ventricular function in healthy cats.

    Science.gov (United States)

    Ward, Jessica L; Schober, Karsten E; Fuentes, Virginia Luis; Bonagura, John D

    2012-10-01

    Although sedation is frequently used to facilitate patient compliance in feline echocardiography, the effects of sedative drugs on echocardiographic variables have been poorly documented. This study investigated the effects of two sedation protocols on echocardiographic indices in healthy cats, with special emphasis on the assessment of left atrial size and function, as well as left ventricular diastolic performance. Seven cats underwent echocardiography (transthoracic two-dimensional, spectral Doppler, color flow Doppler and tissue Doppler imaging) before and after sedation with both acepromazine (0.1 mg/kg IM) and butorphanol (0.25 mg/kg IM), or acepromazine (0.1 mg/kg IM), butorphanol (0.25 mg/kg IM) and ketamine (1.5 mg/kg IV). Heart rate increased significantly following acepromazine/butorphanol/ketamine (mean±SD of increase, 40±26 beats/min) and non-invasive systolic blood pressure decreased significantly following acepromazine/butorphanol (mean±SD of decrease, 12±19 mmHg). The majority of echocardiographic variables were not significantly different after sedation compared with baseline values. Both sedation protocols resulted in mildly decreased left ventricular end-diastolic dimension and mildly increased left ventricular end-diastolic wall thickness. This study therefore failed to demonstrate clinically meaningful effects of these sedation protocols on echocardiographic measurements, suggesting that sedation with acepromazine, butorphanol and/or ketamine can be used to facilitate echocardiography in healthy cats.

  4. Statistics on gene-based laser speckles with a small number of scatterers: implications for the detection of polymorphism in the Chlamydia trachomatis omp1 gene

    Science.gov (United States)

    Ulyanov, Sergey S.; Ulianova, Onega V.; Zaytsev, Sergey S.; Saltykov, Yury V.; Feodorova, Valentina A.

    2018-04-01

    The transformation mechanism for a nucleotide sequence of the Chlamydia trachomatis gene into a speckle pattern has been considered. The first and second-order statistics of gene-based speckles have been analyzed. It has been demonstrated that gene-based speckles do not obey Gaussian statistics and belong to the class of speckles with a small number of scatterers. It has been shown that gene polymorphism can be easily detected through analysis of the statistical characteristics of gene-based speckles.

  5. "Porcelain heart" cardiomyopathy secondary to hyperparathyroidism: radiographic, echocardiographic, and cardiac CT appearances.

    LENUS (Irish Health Repository)

    Freeman, James

    2012-02-01

    We report the radiographic, echocardiographic and cardiac CT appearances of \\'porcelain heart\\' in an 85-year-old woman who presented with progressive heart failure. The extensive myocardial calcification was secondary to hyperparathyroidism with renal failure.

  6. "Porcelain heart" cardiomyopathy secondary to hyperparathyroidism: radiographic, echocardiographic, and cardiac CT appearances.

    LENUS (Irish Health Repository)

    Freeman, James

    2010-11-01

    We report the radiographic, echocardiographic and cardiac CT appearances of \\'porcelain heart\\' in an 85-year-old woman who presented with progressive heart failure. The extensive myocardial calcification was secondary to hyperparathyroidism with renal failure.

  7. Demonstration of a Speckle Based Sensing with Pulse-Doppler Radar for Vibration Detection

    Directory of Open Access Journals (Sweden)

    Nisan Ozana

    2018-05-01

    Full Text Available In previous works, an optical technique for extraction and separation of remote static vibrations has been demonstrated. In this paper, we will describe an approach in which RF speckle movement is used to extract remote vibrations of a static target. The use of conventional radar Doppler methods is not suitable for detecting vibrations of static targets. In addition, the speckle method has an important advantage, in that it is able to detect vibrations at far greater distances than what is normally detected in classical optical methods. The experiment described in this paper was done using a motorized vehicle, which engine was turned on and off. The results showed that the system was able to distinguish between the different engine states, and in addition, was able to determine the vibration frequency of the engine. The first step towards real time detection of human vital signs using RF speckle patterns is presented.

  8. Views of physicians in training on the ethical and legal issues in preliminary reporting of echocardiographic data.

    Science.gov (United States)

    McDonald, R W; Rice, M J; Marcella, C P; Reller, M D; Imus, R L

    1991-01-01

    Cardiac sonographers may be pressured by physicians into giving diagnostic interpretations of echocardiographic data. This study investigated the issue of preliminary reporting of echocardiographic data. A questionnaire was sent to 292 physicians; 85 physicians (29%) responded. Seventy-two physicians (87%) thought they had more than a minimal knowledge of echocardiography, 94% wanted a written or verbal preliminary report, and 84% thought that giving a preliminary report should be part of the cardiac sonographer's job. If abnormalities were found, 80% wanted the results before a cardiologist reviewed the study, and 56% would want a diagnostic rather than a descriptive report. Fifty-four physicians (64%) would pressure the cardiac sonographer into giving a preliminary echocardiographic report and would use this information to manage the patient. The majority of the physicians thought that it is legal for the cardiac sonographer to give a preliminary echocardiogram report. Eighty percent said that the cardiac sonographer would not be "practicing medicine without a license," and 82% that the sonographer would not be "aiding and abetting the unauthorized practice of medicine." This data would indicate that physicians at Oregon Health Sciences University want the cardiac sonographer to give preliminary echocardiographic results, even though the sonographer may be breaking state statutes.

  9. Echocardiographic and Fluoroscopic Fusion Imaging for Procedural Guidance: An Overview and Early Clinical Experience.

    Science.gov (United States)

    Thaden, Jeremy J; Sanon, Saurabh; Geske, Jeffrey B; Eleid, Mackram F; Nijhof, Niels; Malouf, Joseph F; Rihal, Charanjit S; Bruce, Charles J

    2016-06-01

    There has been significant growth in the volume and complexity of percutaneous structural heart procedures in the past decade. Increasing procedural complexity and accompanying reliance on multimodality imaging have fueled the development of fusion imaging to facilitate procedural guidance. The first clinically available system capable of echocardiographic and fluoroscopic fusion for real-time guidance of structural heart procedures was approved by the US Food and Drug Administration in 2012. Echocardiographic-fluoroscopic fusion imaging combines the precise catheter and device visualization of fluoroscopy with the soft tissue anatomy and color flow Doppler information afforded by echocardiography in a single image. This allows the interventionalist to perform precise catheter manipulations under fluoroscopy guidance while visualizing critical tissue anatomy provided by echocardiography. However, there are few data available addressing this technology's strengths and limitations in routine clinical practice. The authors provide a critical review of currently available echocardiographic-fluoroscopic fusion imaging for guidance of structural heart interventions to highlight its strengths, limitations, and potential clinical applications and to guide further research into value of this emerging technology. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  10. Temporal Changes in Left Ventricular Mechanics: Impact of Bed Rest and Exercise

    Science.gov (United States)

    Scott, Jessica M.; Matz, Timothy; Caine, Timothy; Martin, David S.; Downs, Meghan; Ploutz-Snyder, Lori

    2014-01-01

    BACKGROUND Current techniques used to assess cardiac function following spaceflight or head-down tilt bed rest (HDTBR) involve invasive and time consuming procedures such as Swan-Ganz catheterization or cardiac magnetic resonance imaging. An alternative approach, echocardiography, can monitor cardiac morphology and function via sequential measurements of left ventricular (LV) mass and ejection fraction (EF). However, LV mass and EF are insensitive measures of early (subclinical) cardiac deconditioning, and a decrease in LV mass and EF become evident only once significant deconditioning has already occurred. The use of more sensitive and specific echocardiographic techniques such as speckle tracking imaging may address the current limitations of conventional cardiac imaging techniques to provide insight into the magnitude and time course of cardiac deconditioning. METHODS Speckle tracking assessment of longitudinal, radial, and circumferential strain and twist was used to evaluate the impact of 70 days of HDTBR (n=7) and HDTBR + exercise (n=11) on temporal changes in LV mechanics. Echocardiograms were performed pre (BR-2), during (BR31, 70), and following (BR+4hr) HDTBR. Multi-level modeling was used to evaluate the effect of HDTBR condition (Control, Exercise) on cardiac variables. RESULTS Compared to BR-2, longitudinal (BR-2: - 19.0 +/- 1.8%; BR31: -15.9 +/- 2.4%; BR70: -14.9 +/- 2.4%; BR+4hr: -16.0 +/- 2.1%) and radial (BR-2: 15.0 +/- 1.9%; BR31: 12.3 +/- 2.4%; BR70: 11.3 +/- 2.2%; BR+4hr: 13.5 +/- 2.5% ) strains were significantly impaired during and following bed rest (pmechanics for longitudinal strain (BR-2: -19.1 +/- 1.5%; BR 31: -19.0 +/- 2.4%; BR70: -19.1 +/- 2.7%; BR+4hr: -17.8 +/- 2.1%), radial strain (BR-2: 13.8 +/- 2.4; BR31: 14.7 +/- 2.4; BR70: 14.4 +/- 1.6; BR+4hr: 14.4 +/- 2.4), and twist (BR-2: 17.8 +/- 3.6deg; BR31: 18.0 +/- 3.6deg; BR70: 18.2 +/- 5.9deg; BR+4hr: 18.3 +/- 4.2deg). CONCLUSIONS Speckle-tracking echocardiography provides important

  11. Value of tissue Doppler-derived Tei index and two-dimensional speckle tracking imaging derived longitudinal strain on predicting outcome of patients with light-chain cardiac amyloidosis.

    Science.gov (United States)

    Liu, Dan; Hu, Kai; Herrmann, Sebastian; Cikes, Maja; Ertl, Georg; Weidemann, Frank; Störk, Stefan; Nordbeck, Peter

    2017-06-01

    Prognosis of patients with light-chain cardiac amyloidosis (AL-CA) is poor. Speckle tracking imaging (STI) derived longitudinal deformation parameters and Doppler-derived left ventricular (LV) Tei index are valuable predictors of outcome in patients with AL-CA. We estimated the prognostic utility of Tei index and deformation parameters in 58 comprehensively phenotyped patients with AL-CA after a median follow-up of 365 days (quartiles 121, 365 days). The primary end point was all-cause mortality. 19 (33%) patients died during follow-up. Tei index (0.89 ± 0.29 vs. 0.61 ± 0.16, p < 0.001) and E to global early diastolic strain rate ratio (E/GLSR dias ) were higher while global longitudinal systolic strain (GLS sys ) was lower in non-survivors than in survivors (all p < 0.05). Tei index, NYHA functional class, GLS sys and E/GLSR dias were independent predictors of all-cause mortality risk, and Tei index ≥0.9 (HR 7.01, 95% CI 2.43-20.21, p < 0.001) was the best predictor of poor outcome. Combining Tei index and GLS sys yielded the best results on predicting death within 1 year (100% with Tei index ≥0.9 and GLS sys ≤13%) or survival (95% with Tei index ≤0.9 and GLS sys ≥13%). We conclude that 1-year mortality risk in AL-CA patients can be reliably predicted using Tei index or deformation parameters, with combined analysis offering best performance.

  12. The ISWI chromatin remodeler organizes the hsrω ncRNA-containing omega speckle nuclear compartments.

    Directory of Open Access Journals (Sweden)

    Maria C Onorati

    2011-05-01

    Full Text Available The complexity in composition and function of the eukaryotic nucleus is achieved through its organization in specialized nuclear compartments. The Drosophila chromatin remodeling ATPase ISWI plays evolutionarily conserved roles in chromatin organization. Interestingly, ISWI genetically interacts with the hsrω gene, encoding multiple non-coding RNAs (ncRNA essential, among other functions, for the assembly and organization of the omega speckles. The nucleoplasmic omega speckles play important functions in RNA metabolism, in normal and stressed cells, by regulating availability of hnRNPs and some other RNA processing proteins. Chromatin remodelers, as well as nuclear speckles and their associated ncRNAs, are emerging as important components of gene regulatory networks, although their functional connections have remained poorly defined. Here we provide multiple lines of evidence showing that the hsrω ncRNA interacts in vivo and in vitro with ISWI, regulating its ATPase activity. Remarkably, we found that the organization of nucleoplasmic omega speckles depends on ISWI function. Our findings highlight a novel role for chromatin remodelers in organization of nucleoplasmic compartments, providing the first example of interaction between an ATP-dependent chromatin remodeler and a large ncRNA.

  13. Speckle Reduction on Ultrasound Liver Images Based on a Sparse Representation over a Learned Dictionary

    Directory of Open Access Journals (Sweden)

    Mohamed Yaseen Jabarulla

    2018-05-01

    Full Text Available Ultrasound images are corrupted with multiplicative noise known as speckle, which reduces the effectiveness of image processing and hampers interpretation. This paper proposes a multiplicative speckle suppression technique for ultrasound liver images, based on a new signal reconstruction model known as sparse representation (SR over dictionary learning. In the proposed technique, the non-uniform multiplicative signal is first converted into additive noise using an enhanced homomorphic filter. This is followed by pixel-based total variation (TV regularization and patch-based SR over a dictionary trained using K-singular value decomposition (KSVD. Finally, the split Bregman algorithm is used to solve the optimization problem and estimate the de-speckled image. The simulations performed on both synthetic and clinical ultrasound images for speckle reduction, the proposed technique achieved peak signal-to-noise ratios of 35.537 dB for the dictionary trained on noisy image patches and 35.033 dB for the dictionary trained using a set of reference ultrasound image patches. Further, the evaluation results show that the proposed method performs better than other state-of-the-art denoising algorithms in terms of both peak signal-to-noise ratio and subjective visual quality assessment.

  14. Single-shot speckle reduction in numerical reconstruction of digitally recorded holograms: comment.

    Science.gov (United States)

    Maycock, Jonathan; Hennelly, Bryan; McDonald, John

    2015-09-01

    We comment on a recent Letter by Hincapie et al. [Opt. Lett.40, 1623 (2015)], in which the authors proposed a method to reduce the speckle noise in digital holograms. This method was previously published by us in Maycock ["Improving reconstructions of digital holograms," Ph.D. thesis (National University of Ireland, 2012)] and Maycock and Hennelly [Improving Reconstructions of Digital Holograms: Speckle Reduction and Occlusions in Digital Holography (Lambert Academic, 2014)]. We also wish to highlight an important limitation of the method resulting from the superposition of different perspectives of the object/scene, which was not addressed in their Letter.

  15. Laser speckle technique to study the effect of chemical pre-treatment on the quality of minimally processed apples

    International Nuclear Information System (INIS)

    Minz, Preeti D; Nirala, A K

    2016-01-01

    In the present study, the laser speckle technique has been used for the quality evaluation of chemically treated cut apples. Chemical pre-treatment includes 1% (w/v) solution of citric acid (CA), sodium chloride (SC), and a combination of CA and sodium chloride (CS). The variation in weight loss, respiration rate, total soluble solids (TSS), titratable acidity (TA), and absorbance of chemically treated cut apples stored at 5 °C was monitored for 11 d. The speckle grain size was calculated by an autocovariance method from the speckled images of freshly cut chemically treated apples. The effect of chemicals on TSS and the TA content variation of the cut apples were well correlated to the linear speckle grain size. Circular degree of polarization confirms the presence of a small scatterer and hence Rayleigh diffusion region. For all the treated cut apples, a decrease in the concentration of small particles nearly after the mid-period of storage results in the fast decay of circular degree of polarization. For non-invasive and fast analysis of the chemical constituent of fruits during minimal processing, the laser speckle can be practically used in the food industry. (paper)

  16. Laser speckle technique to study the effect of chemical pre-treatment on the quality of minimally processed apples

    Science.gov (United States)

    Minz, Preeti D.; Nirala, A. K.

    2016-04-01

    In the present study, the laser speckle technique has been used for the quality evaluation of chemically treated cut apples. Chemical pre-treatment includes 1% (w/v) solution of citric acid (CA), sodium chloride (SC), and a combination of CA and sodium chloride (CS). The variation in weight loss, respiration rate, total soluble solids (TSS), titratable acidity (TA), and absorbance of chemically treated cut apples stored at 5 °C was monitored for 11 d. The speckle grain size was calculated by an autocovariance method from the speckled images of freshly cut chemically treated apples. The effect of chemicals on TSS and the TA content variation of the cut apples were well correlated to the linear speckle grain size. Circular degree of polarization confirms the presence of a small scatterer and hence Rayleigh diffusion region. For all the treated cut apples, a decrease in the concentration of small particles nearly after the mid-period of storage results in the fast decay of circular degree of polarization. For non-invasive and fast analysis of the chemical constituent of fruits during minimal processing, the laser speckle can be practically used in the food industry.

  17. Estudio de técnicas speckle opto-digitales

    OpenAIRE

    Henao Henao, Rodrigo de Jesús

    1997-01-01

    El presente Trabajo de Tesis se dirigió a la investigación, creación, desarrollo e implementación de técnicas que hacen uso del speckle y de su correlación digital, siendo su representante mas exitoso el DPSI. Doctor en Física(Facultad de Ciencias Exactas)

  18. Speckle contrast diffuse correlation tomography of complex turbid medium flow

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chong; Irwin, Daniel; Lin, Yu; Shang, Yu; He, Lian; Kong, Weikai; Yu, Guoqiang [Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky 40506 (United States); Luo, Jia [Department of Pharmacology and Nutritional Sciences, University of Kentucky, Lexington, Kentucky 40506 (United States)

    2015-07-15

    Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupled to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary

  19. Speckle noise reduction technique for Lidar echo signal based on self-adaptive pulse-matching independent component analysis

    Science.gov (United States)

    Xu, Fan; Wang, Jiaxing; Zhu, Daiyin; Tu, Qi

    2018-04-01

    Speckle noise has always been a particularly tricky problem in improving the ranging capability and accuracy of Lidar system especially in harsh environment. Currently, effective speckle de-noising techniques are extremely scarce and should be further developed. In this study, a speckle noise reduction technique has been proposed based on independent component analysis (ICA). Since normally few changes happen in the shape of laser pulse itself, the authors employed the laser source as a reference pulse and executed the ICA decomposition to find the optimal matching position. In order to achieve the self-adaptability of algorithm, local Mean Square Error (MSE) has been defined as an appropriate criterion for investigating the iteration results. The obtained experimental results demonstrated that the self-adaptive pulse-matching ICA (PM-ICA) method could effectively decrease the speckle noise and recover the useful Lidar echo signal component with high quality. Especially, the proposed method achieves 4 dB more improvement of signal-to-noise ratio (SNR) than a traditional homomorphic wavelet method.

  20. Close Binary Star Speckle Interferometry on the McMath-Pierce 0.8-Meter Solar Telescope

    Science.gov (United States)

    Wiley, Edward; Harshaw, Richard; Jones, Gregory; Branston, Detrick; Boyce, Patrick; Rowe, David; Ridgely, John; Estrada, Reed; Genet, Russell

    2015-09-01

    Observations were made in April 2014 to assess the utility of the 0.8-meter solar telescope at the McMath-Pierce Solar Observatory at Kitt Peak National Observatory for performing speckle interferometry observations of close binary stars. Several configurations using science cameras, acquisition cameras, eyepieces, and flip mirrors were evaluated. Speckle images were obtained and recommendations for further improvement of the acquisition system are presented.

  1. Dynamic laser speckle to detect motile bacterial response of Pseudomonas aeruginosa

    International Nuclear Information System (INIS)

    Sendra, H; Murialdo, S; Passoni, L

    2007-01-01

    This proposal deals with the technique for detection of motile response of Pseudomonas aeruginosa using dynamic laser speckle or biospeckle as an alternative method. The study of bacterial displacement plays an essential role in biocatalysts processes and biodegradation. Hence, some biodegrading enzymes are benign catalytic that could be used for the production of industrially useful compounds as well as in wastewater treatments. This work presents an experimental set up and a computational process using frame sequences of dynamic laser speckle as a novel application. The objective was the detection of different levels of motility in bacteria. The encouraging results were achieved through a direct and non invasive observation method of the phenomenon

  2. Speckle-illuminated fluorescence confocal microscopy, using a digital micro-mirror device

    International Nuclear Information System (INIS)

    Jiang, Shi-Hong; Walker, John G

    2009-01-01

    An implementation of a speckle-illuminated fluorescence confocal microscope using a digital micro-mirror device (DMD) is described. The DMD not only projects a sequence of imaged binary speckle patterns onto the specimen at a very high frame rate but also operates as a spatial light modulator to perform real-time optical data processing. Frame averaging is accomplished by CCD charge accumulation during a single exposure. The recorded time-averaged image is a confocal image plus an unwanted non-confocal image which can be removed by recording a separate image. Experimental results with image acquisition within a fraction of a second are shown. Images of a thin biological sample are also shown to demonstrate practical application of the technique

  3. Polarization speckles and generalized Stokes vector wave: a review [invited

    DEFF Research Database (Denmark)

    Takeda, Mitsuo; Wang, Wei; Hanson, Steen Grüner

    2010-01-01

    We review some of the statistical properties of polarization-related speckle phenomena, with an introduction of a less known concept of polarization speckles and their spatial degree of polarization. As a useful means to characterize twopoint vector field correlations, we review the generalized...... Stokes parameters proposed by Korotkova and Wolf, and introduce its time-domain representation to describe the space-time evolution of the correlation between random electric vector fields at two different space-time points. This time-domain generalized Stokes vector, with components similar to those...... of the beam coherence polarization matrix proposed by Gori, is shown to obey the wave equation in exact analogy to a coherence function of scalar fields. Because of this wave nature, the time-domain generalized Stokes vector is referred to as generalized Stokes vector wave in this paper....

  4. An optical sensor for local strain measuring of an object by means of a speckle correlation method

    Czech Academy of Sciences Publication Activity Database

    Horváth, P.; Šmíd, Petr; Hrabovský, M.; Hamarová, Ivana

    2012-01-01

    Roč. 106, s3 (2012), s. 425-427 ISSN 0009-2770 R&D Projects: GA AV ČR KAN301370701 Institutional research plan: CEZ:AV0Z10100521 Keywords : non-contact measurement * strain * speckle * speckle correlation Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.453, year: 2012

  5. Echocardiographic study of the cardiac state in systemic scleroderma

    International Nuclear Information System (INIS)

    Kotel'nikova, G.P.; Guseva, N.G.

    1986-01-01

    Echocardiographic investigation in 65 patients with systemic scleroderma showed that the left ventricular syes and indices of central hemodynamics were frequently lowered in them; an increase in sizes was observed mainly in the patients with stage 2-3 of disease. Echocardiography made it possible to specify the nature of cardiac pathology and brought to light some additional features of the involvement of different heart membranes in systemic scleroderma

  6. Quantitative, depth-resolved determination of particle motion using multi-exposure, spatial frequency domain laser speckle imaging.

    Science.gov (United States)

    Rice, Tyler B; Kwan, Elliott; Hayakawa, Carole K; Durkin, Anthony J; Choi, Bernard; Tromberg, Bruce J

    2013-01-01

    Laser Speckle Imaging (LSI) is a simple, noninvasive technique for rapid imaging of particle motion in scattering media such as biological tissue. LSI is generally used to derive a qualitative index of relative blood flow due to unknown impact from several variables that affect speckle contrast. These variables may include optical absorption and scattering coefficients, multi-layer dynamics including static, non-ergodic regions, and systematic effects such as laser coherence length. In order to account for these effects and move toward quantitative, depth-resolved LSI, we have developed a method that combines Monte Carlo modeling, multi-exposure speckle imaging (MESI), spatial frequency domain imaging (SFDI), and careful instrument calibration. Monte Carlo models were used to generate total and layer-specific fractional momentum transfer distributions. This information was used to predict speckle contrast as a function of exposure time, spatial frequency, layer thickness, and layer dynamics. To verify with experimental data, controlled phantom experiments with characteristic tissue optical properties were performed using a structured light speckle imaging system. Three main geometries were explored: 1) diffusive dynamic layer beneath a static layer, 2) static layer beneath a diffuse dynamic layer, and 3) directed flow (tube) submerged in a dynamic scattering layer. Data fits were performed using the Monte Carlo model, which accurately reconstructed the type of particle flow (diffusive or directed) in each layer, the layer thickness, and absolute flow speeds to within 15% or better.

  7. Elastic modulus measurements of LDEF glasses and glass-ceramics using a speckle technique

    International Nuclear Information System (INIS)

    Wiedlocher, D.E.; Kinser, D.L.

    1992-01-01

    Elastic moduli of five glass types and the glass-ceramic Zerodur, exposed to a near-earth orbit environment on the Long Duration Exposure Facility (LDEF), were compared to that of unexposed samples. A double exposure speckle photography technique utilizing 633 nm laser light was used in the production of the speckle pattern. Subsequent illumination of a double exposed negative using the same wavelength radiation produces Young's fringes from which the in-plane displacements are measured. Stresses imposed by compressive loading produced measurable strains in the glasses and glass-ceramic

  8. Measurement of elasto-plastic deformations by speckle interferometry

    Science.gov (United States)

    Bova, Marco; Bruno, Luigi; Poggialini, Andrea

    2010-09-01

    In the paper the authors present an experimental equipment for elasto-plastic characterization of engineering materials by tensile tests. The stress state is imposed to a dog bone shaped specimen by a testing machine fixed on the optical table and designed for optimizing the performance of a speckle interferometer. All three displacement components are measured by a portable speckle interferometer fed by three laser diodes of 50 mW, by which the deformations of a surface of about 6×8 mm2 can be fully analyzed in details. All the equipment is driven by control electronics designed and realized on purpose, by which it is possible to accurately modify the intensity of the illumination sources, the position of a PZT actuator necessary for applying phase-shifting procedure, and the overall displacement applied to the specimen. The experiments were carried out in National Instrument LabVIEW environment, while the processing of the experimental data in Wolfram Mathematica environment. The paper reports the results of the elasto-plastic characterization of a high strength steel specimen.

  9. Speckle evolution with multiple steps of least-squares phase removal

    CSIR Research Space (South Africa)

    Chen, M

    2011-08-01

    Full Text Available vortex density and scintillation index. Statistical results show that almost all the optical vortices can be removed from a speckle field, which finally decays into a quasiplane wave after such an iterative process....

  10. Assessment of right ventricular longitudinal strain by 2D speckle tracking imaging compared with RV function and hemodynamics in pulmonary hypertension.

    Science.gov (United States)

    Li, Yidan; Wang, Yidan; Meng, Xiangli; Zhu, Weiwei; Lu, Xiuzhang

    2017-11-01

    The right ventricular longitudinal strain (RVLS) of pulmonary hypertension (PH) patients and its relationship with RV function parameters measured by echocardiography and hemodynamic parameters measured by right heart catheterization was investigated. According to the WHO functional class (FC), 66 PH patients were divided into FC I/II (group 1) and III/IV (group 2). RV function parameters were measured by echocardiographic examinations. Hemodynamic parameters were obtained by right heart catheterization. Patients in group 2 had higher systolic pulmonary artery pressure (sPAP; P good sensitivity and specificity. Evidence has shown that RVLS measurement can provide the much-needed and reliable information on RV function and hemodynamics. Therefore, this qualifies as a patient-friendly approach for the clinical management of PH patients.

  11. Utilization of a pressure sensor guidewire to measure bileaflet mechanical valve gradients: hemodynamic and echocardiographic sequelae.

    Science.gov (United States)

    Doorey, Andrew J; Gakhal, Mandip; Pasquale, Michael J

    2006-04-01

    Suspected prosthetic valve dysfunction is a difficult clinical problem, because of the high risk of repeat valvular surgery. Echocardiographic measurements of prosthetic valvular dysfunction can be misleading, especially with bileaflet valves. Direct measurement of trans-valvular gradients is problematic because of potentially serious catheter entrapment issues. We report a case in which a high-fidelity pressure sensor angioplasty guidewire was used to cross prosthetic mitral and aortic valves in a patient, with hemodynamic and echocardiographic assessment. This technique was safe and effective, refuting the inaccurate non-invasive tests that over-estimated the aortic valvular gradient.

  12. Waveguide generated mitigation of speckle and scintillation on an actively illuminated target

    Science.gov (United States)

    Moore, Trevor D.; Raynor, Robert A.; Spencer, Mark F.; Schmidt, Jason D.

    2016-09-01

    Active illumination is often used when passive illumination cannot produce enough signal intensity to be a reliable imaging method. However, an increase in signal intensity is often achieved by using highly coherent laser sources, which produce undesirable effects such as speckle and scintillation. The deleterious effects of speckle and scintillation are often so immense that the imaging camera cannot receive intelligible data, thereby rendering the active illumination technique useless. By reducing the spatial coherence of the laser beam that is actively illuminating the object, it is possible to reduce the corruption of the received data caused by speckle and scintillation. The waveguide method discussed in this paper reduces spatial coherence through multiple total internal reflections, which create multiple virtual sources of diverse path lengths. The differing path lengths between the virtual sources and the target allow for the temporal coherence properties of the laser to be translated into spatial coherence properties. The resulting partial spatial coherence helps to mitigate the self-interference of the beam as it travels through the atmosphere and reflects off of optically rough targets. This mitigation method results in a cleaner, intelligible image that may be further processed for the intended use, unlike its unmitigated counterpart. Previous research has been done to independently reduce speckle or scintillation by way of spatial incoherence, but there has been no focus on modeling the waveguide, specifically the image plane the waveguide creates. Utilizing a ray-tracing method we can determine the coherence length of the source necessary to create incoherent spots in the image plane, as well as accurately modeling the image plane.

  13. Laser speckle: theory and applications. January 1970-May 1988 (Citations from the Engineering Index data base). Report for January 1970-May 1988

    International Nuclear Information System (INIS)

    1988-05-01

    This bibliography contains citations concerning applications and theoretical considerations pertaining to laser speckle interferometry. Topics include experimental and theoretical investigations, applications in stress and vibrational analysis, velocity and displacement measurement, and surface analysis. Speckle noise-reduction techniques and speckle photography are also treated. (This updated bibliography contains 247 citations, 22 of which are new entries to the previous edition.)

  14. Coherence and Polarization of Polarization Speckle Generated by Depolarizers and Their Changes through Complex ABCD Matrix

    DEFF Research Database (Denmark)

    Ma, Ning; Hanson, Steen Grüner; Lee, Tim K.

    2015-01-01

    Recent research work on speckle patterns indicates a variation of the polarization state during propagation and its nonuniformly spatial distribution. The preliminary step for the investigation of this polarization speckle is the generation of the corresponding field. In this paper, a kind...... of special depolarizer: the random roughness birefringent screen (RRBS) is introduced to meet this requirement. The statistical properties of the field generated by the depolarizer is investigated and illustrated in terms of the 2x2 beam coherence and polarization matrix (BCPM) with the corresponding degree...... of coherence (DoC). and degree of polarization (DoP) P. The changes of the coherence and polarization when the speckle field propagates through any optical system are analysed within the framework of the complex ABCD-matrix theory....

  15. IMAGE ENHANCEMENT AND SPECKLE REDUCTION OF FULL POLARIMETRIC SAR DATA BY GAUSSIAN MARKOV RANDOM FIELD

    Directory of Open Access Journals (Sweden)

    M. Mahdian

    2013-09-01

    Full Text Available In recent years, the use of Polarimetric Synthetic Aperture Radar (PolSAR data in different applications dramatically has been increased. In SAR imagery an interference phenomenon with random behavior exists which is called speckle noise. The interpretation of data encounters some troubles due to the presence of speckle which can be considered as a multiplicative noise affecting all coherent imaging systems. Indeed, speckle degrade radiometric resolution of PolSAR images, therefore it is needful to perform speckle filtering on the SAR data type. Markov Random Field (MRF has proven to be a powerful method for drawing out eliciting contextual information from remotely sensed images. In the present paper, a probability density function (PDF, which is fitted well with the PolSAR data based on the goodness-of-fit test, is first obtained for the pixel-wise analysis. Then the contextual smoothing is achieved with the MRF method. This novel speckle reduction method combines an advanced statistical distribution with spatial contextual information for PolSAR data. These two parts of information are combined based on weighted summation of pixel-wise and contextual models. This approach not only preserves edge information in the images, but also improves signal-to-noise ratio of the results. The method maintains the mean value of original signal in the homogenous areas and preserves the edges of features in the heterogeneous regions. Experiments on real medium resolution ALOS data from Tehran, and also high resolution full polarimetric SAR data over the Oberpfaffenhofen test-site in Germany, demonstrate the effectiveness of the algorithm compared with well-known despeckling methods.

  16. Algorithmic processing of intrinsic signals in affixed transmission speckle analysis (ATSA) (Conference Presentation)

    Science.gov (United States)

    Ghijsen, Michael T.; Tromberg, Bruce J.

    2017-03-01

    Affixed Transmission Speckle Analysis (ATSA) is a method recently developed to measure blood flow that is based on laser speckle imaging miniaturized into a clip-on form factor the size of a pulse-oximeter. Measuring at a rate of 250 Hz, ATSA is capable or obtaining the cardiac waveform in blood flow data, referred to as the Speckle-Plethysmogram (SPG). ATSA is also capable of simultaneously measuring the Photoplethysmogram (PPG), a more conventional signal related to light intensity. In this work we present several novel algorithms for extracting physiologically relevant information from the combined SPG-PPG waveform data. First we show that there is a slight time-delay between the SPG and PPG that can be extracted computationally. Second, we present a set of frequency domain algorithms that measure harmonic content on pulse-by-pulse basis for both the SPG and PPG. Finally, we apply these algorithms to data obtained from a set of subjects including healthy controls and individuals with heightened cardiovascular risk. We hypothesize that the time-delay and frequency content are correlated with cardiovascular health; specifically with vascular stiffening.

  17. DEPENDENCE OF THE SPECKLE-PATTERNS SIZE AND THEIR CONTRAST ON THE BIOPHYSICAL AND STRUCTURAL PARAMETERS OF BIOLOGICAL TISSUES

    Directory of Open Access Journals (Sweden)

    N. D. Abramovich

    2017-01-01

    Full Text Available Speckle fields are widely used in optical diagnostics of biotissues and evaluation of the functional state of bioobjects. The speckle field is formed by laser radiation scattered from the object under study. It bears information about the average dimensions of the scatterers, the degree of surface roughness makes it possible to judge the structural and biophysical characteristics of individual tissue cells (particles, on the one hand, and the integral optical characteristics of the entire biological tissue. The aim of the study was – the determination of connections between the biophysical and structural characteristics of the biotissue and the light fields inside the biotissues.The model developed of the medium gives a direct relationship between the optical and biophysical parameters of the biotissue. Calculations were carried out using known solutions of the radiation transfer equation, taking into account the multilayer structure of the tissue, multiple scattering in the medium, and multiple reflection of irradiation between the layers.With the increase wavelength, the size of speckles formed by the non-scattered component (direct light of laser radiation increases by a factor of 2 from 400 to 800 μm in the stratum corneum and 5 times from 0.6 to 3 μm for the epidermis and from 0.27 to 1.4 μm to the dermis. Typical values of sizes of speckles formed by the diffraction component of laser radiation for the stratum corneum and epidermis range from 0.02 to 0.15 μm. For the dermis typical spot sizes are up to 0.03 μm. The speckle-spot size of the diffusion component in the dermis can vary from ±10 % at 400 nm and up to ±23 % for 800 nm when the volume concentration of blood capillaries changes. Characteristic dependencies are obtained and biophysical factors associated with the volume concentration of blood and the degree of it’s oxygenation that affect the contrast of the speckle structure in the dermis are discussed.The of speckles

  18. Changes in speckle patterns induced by load application onto an optical fiber and its possible application for sensing purpose

    Science.gov (United States)

    Hasegawa, Makoto; Okumura, Jyun-ya; Hyuga, Akio

    2015-08-01

    Speckle patterns to be observed in an output light spot from an optical fiber are known to be changed due to external disturbances applied onto the optical fiber. In order to investigate possibilities of utilizing such changes in speckle patterns for sensing application, a certain load was applied onto a jacket-covered communication-grade multi-mode glass optical fiber through which laser beams emitted from a laser diode were propagating, and observed changes in speckle patterns in the output light spot from the optical fiber were investigated both as image data via a CCD camera and as an output voltage from a photovoltaic panel irradiated with the output light spot. The load was applied via a load application mechanism in which several ridges were provided onto opposite flat plates and a certain number of weights were placed there so that corrugated bending of the optical fiber was intentionally induced via load application due to the ridges. The obtained results showed that the number of speckles in the observed pattern in the output light spot as well as the output voltage from the photovoltaic panel irradiated with the output light spot showed decreases upon load application with relatively satisfactory repeatability. When the load was reduced, i.e., the weights were removed, the number of speckles then showed recovery. These results indicate there is a certain possibility of utilizing changes in speckle patterns for sensing of load application onto the optical fiber.

  19. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  20. NT-proBNP, echocardiographic abnormalities and subclinical coronary artery disease in high risk type 2 diabetic patients

    DEFF Research Database (Denmark)

    Reinhard, Henrik; Hansen, Peter R; Wiinberg, Niels

    2012-01-01

    -NT-proBNP and the putative residual abnormalities in such patients are not well described. This study examined echocardiographic measurements of LV hypertrophy, atrial dilatation and LV dysfunction and their relation to P-NT-proBNP levels or subclinical coronary artery disease (CAD) in type 2 diabetic patients......Intensive multifactorial treatment aimed at prevention of cardiovascular (CV) disease may reduce left ventricular (LV) echocardiographic abnormalities in diabetic subjects. Plasma N-terminal (NT)-proBNP predicts CV mortality in diabetic patients but the association between P...

  1. Becoming-Speckled Warbler: Re/Creating Australian Natural History Pedagogy

    Science.gov (United States)

    Stewart, Alistair

    2011-01-01

    The speckled warbler and other woodland birds of south-eastern Australia have declined dramatically since European settlement; many species are at risk of becoming locally and/or nationally extinct. Coincidently, Australian environmental education research of the last decade has largely been silent on the development of pedagogy that reflects the…

  2. Application of speckle decorrelation method for small translation measurements

    Czech Academy of Sciences Publication Activity Database

    Horváth, Pavel; Hrabovský, Miroslav; Šmíd, Petr

    2004-01-01

    Roč. 34, č. 2 (2004), s. 203-218 ISSN 0078-5466 R&D Projects: GA MŠk LN00A015 Institutional research plan: CEZ:AV0Z1010921 Keywords : speckle * decorrelation * in-plane and normal translation Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.308, year: 2004

  3. Evolution of echocardiography in subclinical detection of cancer therapy-related cardiac dysfunction.

    Science.gov (United States)

    Moudgil, Rohit; Hassan, Saamir; Palaskas, Nicolas; Lopez-Mattei, Juan; Banchs, Jose; Yusuf, Syed Wamique

    2018-05-11

    Cancer therapies have resulted in increased survivorship in oncological patients. However, the benefits have been marred by the development of premature cardiovascular disease. The current definition outlines measurement of ejection fraction as a mean to diagnose cancer therapeutic-related cardiac dysfunction (CTRCD); however, up to 58% of the patients do not regain their cardiac function after the CTRCD diagnosis, despite therapeutic interventions. Therefore, there has been a growing interest in the markers for early myocardial changes (ie, changes with normal left ventricular ejection fraction [LVEF]) that may predict the development of subsequent left ventricular ejection fraction reduction or progression to heart failure. This review will highlight the use of diastolic parameters, tissue Doppler imaging (TDI), and speckle tracking echocardiogram (STE) as emerging technologies which can potentially detect cardiac dysfunction thereby stratifying patients for cardioprotective therapies. The goal of this manuscript was to highlight the concepts and discuss the current controversies surrounding these echocardiographic imaging modalities. © 2018 Wiley Periodicals, Inc.

  4. Detection of white spot lesions by segmenting laser speckle images using computer vision methods.

    Science.gov (United States)

    Gavinho, Luciano G; Araujo, Sidnei A; Bussadori, Sandra K; Silva, João V P; Deana, Alessandro M

    2018-05-05

    This paper aims to develop a method for laser speckle image segmentation of tooth surfaces for diagnosis of early stages caries. The method, applied directly to a raw image obtained by digital photography, is based on the difference between the speckle pattern of a carious lesion tooth surface area and that of a sound area. Each image is divided into blocks which are identified in a working matrix by their χ 2 distance between block histograms of the analyzed image and the reference histograms previously obtained by K-means from healthy (h_Sound) and lesioned (h_Decay) areas, separately. If the χ 2 distance between a block histogram and h_Sound is greater than the distance to h_Decay, this block is marked as decayed. The experiments showed that the method can provide effective segmentation for initial lesions. We used 64 images to test the algorithm and we achieved 100% accuracy in segmentation. Differences between the speckle pattern of a sound tooth surface region and a carious region, even in the early stage, can be evidenced by the χ 2 distance between histograms. This method proves to be more effective for segmenting the laser speckle image, which enhances the contrast between sound and lesioned tissues. The results were obtained with low computational cost. The method has the potential for early diagnosis in a clinical environment, through the development of low-cost portable equipment.

  5. Speckle Noise Reduction for the Enhancement of Retinal Layers in Optical Coherence Tomography Images

    Directory of Open Access Journals (Sweden)

    Fereydoon Nowshiravan Rahatabad

    2015-09-01

    Full Text Available Introduction One of the most important pre-processing steps in optical coherence tomography (OCT is reducing speckle noise, resulting from multiple scattering of tissues, which degrades the quality of OCT images. Materials and Methods The present study focused on speckle noise reduction and edge detection techniques. Statistical filters with different masks and noise variances were applied on OCT and test images. Objective evaluation of both types of images was performed, using various image metrics such as peak signal-to-noise ratio (PSNR, root mean square error, correlation coefficient and elapsed time. For the purpose of recovery, Kuan filter was used as an input for edge enhancement. Also, a spatial filter was applied to improve image quality. Results The obtained results were presented as statistical tables and images. Based on statistical measures and visual quality of OCT images, Enhanced Lee filter (3×3 with a PSNR value of 43.6735 in low noise variance and Kuan filter (3×3 with a PSNR value of 37.2850 in high noise variance showed superior performance over other filters. Conclusion Based on the obtained results, by using speckle reduction filters such as Enhanced Lee and Kuan filters on OCT images, the number of compounded images, required to achieve a given image quality, could be reduced. Moreover, use of Kuan filters for promoting the edges allowed smoothing of speckle regions, while preserving image tissue texture.

  6. Doppler echocardiographic predictors of mortality in female rats after myocardial infarction.

    Science.gov (United States)

    Santos, Alexandra Alberta; Helber, Izzo; Flumignan, Ronald L G; Antonio, Ednei L; Carvalho, Antonio C; Paola, Angelo A; Tucci, Paulo J; Moises, Valdir A

    2009-03-01

    Doppler echocardiogram is useful for the evaluation of anatomical and functional changes in late myocardial infarction (MI) in rats. However, no studies have evaluated the prognostic value of echocardiographic parameters 1 week after MI. Doppler echocardiogram was performed in 84 female Wistar rats 1 week after MI to determine infarction size, left chambers dimensions, fractional area change (FAC) of the left ventricle (LV), mitral inflow and tissue Doppler, myocardial performance index (MPI), and signs of pulmonary hypertension. The 365-day follow-up showed 53.6% mortality rate. Nonsurvivors showed larger (P or=0.60 (RR 3.49, 95% CI, 1.80-6.76), LV systolic area >or=0.26 cm(2) (RR 4.38, 95% CI, 1.88-10.21), E/E' ratio >or=20.3 (RR 2.12, 95% CI, 1.15-4.34), and E/A ratio associated with FAC (RR 2.99, 95% CI, 1.44-6.18). Some diastolic and systolic Doppler echocardiographic parameters in rats may be able to predict late mortality risk after MI.

  7. Pseudo-stokes vector from complex signal representation of a speckle pattern and its applications to micro-displacement measurement

    DEFF Research Database (Denmark)

    Wang, W.; Ishijima, R.; Matsuda, A.

    2010-01-01

    As an improvement of the intensity correlation used widely in conventional electronic speckle photography, we propose a new technique for displacement measurement based on correlating Stokes-like parameters derivatives for transformed speckle patterns. The method is based on a Riesz transform of ...... are presented that demonstrate the validity and advantage of the proposed pseudo-Stokes vector correlation technique over conventional intensity correlation technique....... of the intensity speckle pattern, which converts the original real-valued signal into a complex signal. In closest analogy to the polarisation of a vector wave, the Stokes-like vector constructed from the spatial derivative of the generated complex signal has been applied for correlation. Experimental results...

  8. Body size evolution in insular speckled rattlesnakes (Viperidae: Crotalus mitchellii.

    Directory of Open Access Journals (Sweden)

    Jesse M Meik

    2010-03-01

    Full Text Available Speckled rattlesnakes (Crotalus mitchellii inhabit multiple islands off the coast of Baja California, Mexico. Two of the 14 known insular populations have been recognized as subspecies based primarily on body size divergence from putative mainland ancestral populations; however, a survey of body size variation from other islands occupied by these snakes has not been previously reported. We examined body size variation between island and mainland speckled rattlesnakes, and the relationship between body size and various island physical variables among 12 island populations. We also examined relative head size among giant, dwarfed, and mainland speckled rattlesnakes to determine whether allometric differences conformed to predictions of gape size (and indirectly body size evolving in response to shifts in prey size.Insular speckled rattlesnakes show considerable variation in body size when compared to mainland source subspecies. In addition to previously known instances of gigantism on Angel de la Guarda and dwarfism on El Muerto, various degrees of body size decrease have occurred frequently in this taxon, with dwarfed rattlesnakes occurring mostly on small, recently isolated, land-bridge islands. Regression models using the Akaike information criterion (AIC showed that mean SVL of insular populations was most strongly correlated with island area, suggesting the influence of selection for different body size optima for islands of different size. Allometric differences in head size of giant and dwarf rattlesnakes revealed patterns consistent with shifts to larger and smaller prey, respectively.Our data provide the first example of a clear relationship between body size and island area in a squamate reptile species; among vertebrates this pattern has been previously documented in few insular mammals. This finding suggests that selection for body size is influenced by changes in community dynamics that are related to graded differences in area over

  9. Spatial Behaviour of Singularities in Fractal- and Gaussian Speckle Fields

    DEFF Research Database (Denmark)

    Angelsky, Oleg V.; Maksimyak, Alexander P.; Maksimyak, Peter P.

    2009-01-01

    Peculiarities of the spatial behaviour of the dislocation lines resulting from scattering of coherent radiation from random and fractal rough surfaces are studied. The technique of optical correlation is proposed for diagnostics of phase singularities in a complex speckle field by comparing...

  10. Intensity dependent waiting time for strong electron trapping events in speckle stimulated raman scatter

    Energy Technology Data Exchange (ETDEWEB)

    Rose, Harvey [Los Alamos National Laboratory; Daughton, W [Los Alamos National Laboratory; Yin, L [Los Alamos National Laboratory

    2009-01-01

    The onset of Stimulated Raman scatter from an intense laser speckle is the simplest experimentally realizable laser-plasma-interaction environment. Despite this data and recent 3D particle simulations, the controlling mechanism at the onset of backscatter in the kinetic regime when strong electron trapping in the daughter Langmuir wave is a dominant nonlinearity is not understood. This paper explores the consequences of assuming that onset is controlled by large thermal fluctuations. A super exponential dependence of mean reflectivity on speckle intensity in the onset regime is predicted.

  11. Optical characterization of display screens by speckle patterns

    Science.gov (United States)

    Pozo, Antonio M.; Castro, José J.; Rubiño, Manuel

    2013-10-01

    In recent years, flat-panel display (FPD) technology has undergone great development, and now FPDs appear in many devices. A significant element in FPD manufacturing is the display front surface. Manufacturers sell FPDs with different types of front surfaces, which can be matte (also called anti-glare) or glossy screens. Users who prefer glossy screens consider these displays to show more vivid colors compared with matte-screen displays. However, on the glossy screens, external light sources may cause unpleasant reflections that can be reduced by a matte treatment in the front surface. In this work, we present a method to characterize FPD screens using laser-speckle patterns. We characterize three FPDs: a Samsung XL2370 LCD monitor of 23 in. with matte screen, a Toshiba Satellite A100 LCD laptop of 15.4 in. with glossy screen, and a Grammata Papyre 6.1 electronic book reader of 6 in. with ePaper screen (E-ink technology). The results show great differences in speckle-contrast values for the three screens characterized and, therefore, this work shows the feasibility of this method for characterizing and comparing FPDs that have different types of front surfaces.

  12. Real time speckle monitoring to control retinal photocoagulation

    Science.gov (United States)

    Bliedtner, Katharina; Seifert, Eric; Brinkmann, Ralf

    2017-07-01

    Photocoagulation is a treatment modality for several retinal diseases. Intra- and inter-individual variations of the retinal absorption as well as ocular transmission and light scattering makes it impossible to achieve a uniform effective exposure with one set of laser parameters. To guarantee a uniform damage throughout the therapy a real-time control is highly requested. Here, an approach to realize a real-time optical feedback using dynamic speckle analysis in-vivo is presented. A 532 nm continuous wave Nd:YAG laser is used for coagulation. During coagulation, speckle dynamics are monitored by a coherent object illumination using a 633 nm diode laser and analyzed by a CMOS camera with a frame rate up to 1 kHz. An algorithm is presented that can discriminate between different categories of retinal pigment epithelial damage ex-vivo in enucleated porcine eyes and that seems to be robust to noise in-vivo. Tissue changes in rabbits during retinal coagulation could be observed for different lesion strengths. This algorithm can run on a FPGA and is able to calculate a feedback value which is correlated to the thermal and coagulation induced tissue motion and thus the achieved damage.

  13. Speckle reduction for a laser light sectioning sensor

    Directory of Open Access Journals (Sweden)

    Tutsch Rainer

    2015-01-01

    Full Text Available Automated optical inspection is an important test procedure in electronic circuits assembly. Frequently 3d information is required and laser light sectioning sensors are often applied. However, some effects complicate the reliable automatic detection of the shape of such assemblies and their components. The packages of electronic components often are made of black plastics or ceramics so that the intensity available for the optical detection is quite low, especially in comparison to the surface of the PCBs where the components are mounted on. In addition due to rough surfaces of the components and the coherence length of the laser light speckle structures arise. In the work presented here a piezo actuator is used to oscillate the illuminating laser lines along the direction of the lines. The aim is to reduce the visibility of the speckle structures by averaging while maintaining the geometrical shape of the lines. In addition, image processing methods like segmentation and skeletonization are used to allow the detection of the shape of components and assemblies also if materials with distinct differences in the reflectivity are involved. Investigations include the influence of the parameters amplitude and frequency of the piezo actuator.

  14. Echocardiographic predictors of exercise capacity and mortality in chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Schoos, Mikkel Malby; Dalsgaard, Morten; Kjærgaard, Jesper

    2013-01-01

    Chronic obstructive pulmonary disease (COPD) reduces exercise capacity, but lung function parameters do not fully explain functional class and lung-heart interaction could be the explanation. We evaluated echocardiographic predictors of mortality and six minutes walking distance (6MWD), a marker...... for quality of life and mortality in COPD....

  15. Speckle noise reduction for optical coherence tomography based on adaptive 2D dictionary

    Science.gov (United States)

    Lv, Hongli; Fu, Shujun; Zhang, Caiming; Zhai, Lin

    2018-05-01

    As a high-resolution biomedical imaging modality, optical coherence tomography (OCT) is widely used in medical sciences. However, OCT images often suffer from speckle noise, which can mask some important image information, and thus reduce the accuracy of clinical diagnosis. Taking full advantage of nonlocal self-similarity and adaptive 2D-dictionary-based sparse representation, in this work, a speckle noise reduction algorithm is proposed for despeckling OCT images. To reduce speckle noise while preserving local image features, similar nonlocal patches are first extracted from the noisy image and put into groups using a gamma- distribution-based block matching method. An adaptive 2D dictionary is then learned for each patch group. Unlike traditional vector-based sparse coding, we express each image patch by the linear combination of a few matrices. This image-to-matrix method can exploit the local correlation between pixels. Since each image patch might belong to several groups, the despeckled OCT image is finally obtained by aggregating all filtered image patches. The experimental results demonstrate the superior performance of the proposed method over other state-of-the-art despeckling methods, in terms of objective metrics and visual inspection.

  16. Speckle-based at-wavelength metrology of x-ray optics at Diamond Light Source

    Science.gov (United States)

    Wang, Hongchang; Zhou, Tunhe; Kashyap, Yogesh; Sawhney, Kawal

    2017-08-01

    To achieve high resolution and sensitivity on the nanometer scale, further development of X-ray optics is required. Although ex-situ metrology provides valuable information about X-ray optics, the ultimate performance of X-ray optics is critically dependent on the exact nature of the working conditions. Therefore, it is equally important to perform in-situ metrology at the optics' operating wavelength (`at-wavelength' metrology) to optimize the performance of X-ray optics and correct and minimize the collective distortions of the upstream beamline optics, e.g. monochromator, windows, etc. Speckle-based technique has been implemented and further improved at Diamond Light Source. We have demonstrated that the angular sensitivity for measuring the slope error of an optical surface can reach an accuracy of two nanoradians. The recent development of the speckle-based at-wavelength metrology techniques will be presented. Representative examples of the applications of the speckle-based technique will also be given - including optimization of X-ray mirrors and characterization of compound refraction lenses. Such a high-precision metrology technique will be extremely beneficial for the manufacture and in-situ alignment/optimization of X-ray mirrors for next-generation synchrotron beamlines.

  17. Echocardiographic Parameters and Survival in Chagas Heart Disease with Severe Systolic Dysfunction

    International Nuclear Information System (INIS)

    Rassi, Daniela do Carmo; Vieira, Marcelo Luiz Campos; Arruda, Ana Lúcia Martins; Hotta, Viviane Tiemi; Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador

    2014-01-01

    Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction < 35%. Study with retrospective analysis of pre-specified echocardiographic parameters prospectively collected from 60 patients included in the Multicenter Randomized Trial of Cell Therapy in Patients with Heart Diseases (Estudo Multicêntrico Randomizado de Terapia Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p < 0.0001) and E/Em ratio (HR = 0.95; p = 0.1261) were excluded. The indexed left atrial volume was an independent predictor in relation to the endpoint, and values > 70.71 mL/m 2 were associated with a significant increase in mortality (log rank p < 0.0001). The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction

  18. Echocardiographic reference ranges in older children and adolescents in sub-Saharan Africa.

    Science.gov (United States)

    Majonga, Edith D; Rehman, Andrea M; McHugh, Grace; Mujuru, Hilda A; Nathoo, Kusum; Patel, Mohammad S; Munyati, Shungu; Odland, Jon O; Kranzer, Katharina; Kaski, Juan P; Ferrand, Rashida A

    2017-12-01

    Echocardiographic reference ranges are important to identify abnormalities of cardiac dimensions. Reference ranges for children in sub-Saharan Africa have not been established. The aim of this study was to establish echocardiographic z-score references for Black children in sub-Saharan Africa. 282 healthy subjects aged 6-16years (143 [51%] males) with no known history of cardiac disease were enrolled in the study in Harare, Zimbabwe between 2014 and 2016. Standard M-mode echocardiography was performed and nine cardiac chamber dimensions were obtained. Two non-linear statistical models (gamma weighted model and cubic polynomial model) were tested on the data and the best fitting model was used to calculate z-scores of these cardiac chamber measures. The reference ranges are presented on scatter plots against BSA. Normative data for the following cardiac measures were obtained and z-scores calculated: right ventricular diameter at end diastole (RVEDD); left ventricular diameter at end diastole (LVEDD) and systole (LVESD); interventricular septal wall thickness at end diastole (IVSd) and systole (IVSs); left ventricular posterior wall thickness at end diastole (LVPWd) and systole (LVPWs); left atrium diameter at end systole (LA) and tricuspid annular plane systolic excursion (TAPSE). Girls had higher values for BMI and heart rate than boys (p=0.048 and p=0.001, respectively). Mean interventricular septal and left ventricular posterior walls thickness was higher than published normal values in predominantly Caucasian populations. These are the first echocardiographic reference ranges for children from sub Saharan Africa and will allow accurate assessment of cardiac dimensions in clinical practice. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Echocardiographic Parameters and Survival in Chagas Heart Disease with Severe Systolic Dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Rassi, Daniela do Carmo, E-mail: dani.rassi@hotmail.com [Faculdade de Medicina e Hospital das Clínicas da Universidade Federal de Goiás (UFG), Goiânia, GO (Brazil); Vieira, Marcelo Luiz Campos [Instituto do Coração da Faculdade de Medicina da Universidade de São Paulo (USP), São Paulo, SP (Brazil); Arruda, Ana Lúcia Martins [Instituto de Radiologia da Faculdade de Medicina da Universidade de São Paulo (USP), São Paulo, SP (Brazil); Hotta, Viviane Tiemi [Instituto do Coração da Faculdade de Medicina da Universidade de São Paulo (USP), São Paulo, SP (Brazil); Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador [Faculdade de Medicina e Hospital das Clínicas da Universidade Federal de Goiás (UFG), Goiânia, GO (Brazil)

    2014-03-15

    Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction < 35%. Study with retrospective analysis of pre-specified echocardiographic parameters prospectively collected from 60 patients included in the Multicenter Randomized Trial of Cell Therapy in Patients with Heart Diseases (Estudo Multicêntrico Randomizado de Terapia Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p < 0.0001) and E/Em ratio (HR = 0.95; p = 0.1261) were excluded. The indexed left atrial volume was an independent predictor in relation to the endpoint, and values > 70.71 mL/m{sup 2} were associated with a significant increase in mortality (log rank p < 0.0001). The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction.

  20. Color quality improvement of reconstructed images in color digital holography using speckle method and spectral estimation

    Science.gov (United States)

    Funamizu, Hideki; Onodera, Yusei; Aizu, Yoshihisa

    2018-05-01

    In this study, we report color quality improvement of reconstructed images in color digital holography using the speckle method and the spectral estimation. In this technique, an object is illuminated by a speckle field and then an object wave is produced, while a plane wave is used as a reference wave. For three wavelengths, the interference patterns of two coherent waves are recorded as digital holograms on an image sensor. Speckle fields are changed by moving a ground glass plate in an in-plane direction, and a number of holograms are acquired to average the reconstructed images. After the averaging process of images reconstructed from multiple holograms, we use the Wiener estimation method for obtaining spectral transmittance curves in reconstructed images. The color reproducibility in this method is demonstrated and evaluated using a Macbeth color chart film and staining cells of onion.

  1. Co-localisation studies of Arabidopsis SR splicing factors reveal different types of speckles in plant cell nuclei

    International Nuclear Information System (INIS)

    Lorkovic, Zdravko J.; Hilscher, Julia; Barta, Andrea

    2008-01-01

    SR proteins are multidomain splicing factors which are important for spliceosome assembly and for regulation of alternative splicing. In mammalian nuclei these proteins localise to speckles from where they are recruited to transcription sites. By using fluorescent protein fusion technology and different experimental approaches it has been shown that Arabidopsis SR proteins, in addition to diffuse nucleoplasmic staining, localise into an irregular nucleoplasmic network resembling speckles in mammalian cells. As Arabidopsis SR proteins fall into seven conserved sub-families we investigated co-localisation of members of the different sub-families in transiently transformed tobacco protoplast. Here we demonstrate the new finding that members of different SR protein sub-families localise into distinct populations of nuclear speckles with no, partial or complete co-localisation. This is particularly interesting as we also show that these proteins do interact in a yeast two-hybrid assay as well as in pull-down and in co-immunopreciptiation assays. Our data raise the interesting possibility that SR proteins are partitioned into distinct populations of nuclear speckles to allow a more specific recruitment to the transcription/pre-mRNA processing sites of particular genes depending on cell type and developmental stage

  2. Superpositions of higher-order bessel beams and nondiffracting speckle fields

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2009-08-01

    Full Text Available speckle fields. The paper reports on illuminating a ring slit aperture with light which has an azimuthal phase dependence, such that the field produced is a superposition of two higher-order Bessel beams. In the case that the phase dependence of the light...

  3. A rapid echocardiographic screening protocol for rheumatic heart disease in Samoa: a high prevalence of advanced disease.

    Science.gov (United States)

    Allen, Marvin; Allen, John; Naseri, Take; Gardner, Rebecca; Tolley, Dennis; Allen, Lori

    2017-10-01

    Echocardiography has been proposed as a method to screen children for rheumatic heart disease. The World Heart Federation has established guidelines for echocardiographic screening. In this study, we describe a rapid echocardiogram screening protocol according to the World Heart Federation guidelines in Samoa, endemic for rheumatic heart disease. We performed echocardiogram screening in schoolchildren in Samoa between 2013 and 2015. A brief screening echocardiogram was performed on all students. Children with predefined criteria suspicious for rheumatic hear diseases were referred for a more comprehensive echocardiogram. Complete echocardiograms were classified according to the World Heart Federation guidelines and severity of valve disease. Echocardiographic screening was performed on 11,434 children, with a mean age of 10.2 years; 51% of them were females. A total of 558 (4.8%) children underwent comprehensive echocardiography, including 49 students who were randomly selected as controls. Definite rheumatic heart disease was observed in 115 students (10.0 per 1000): 92 students were classified as borderline (8.0 per 1000) and 23 with CHD. Advanced disease was identified in 50 students (4.4 per 1000): 15 with severe mitral regurgitation, five with severe aortic regurgitation, 11 with mitral stenoses, and 19 with mitral and aortic valve disease. We successfully applied a rapid echocardiographic screening protocol to a large number of students over a short time period - 28 days of screening over a 3-year time period - to identify a high prevalence of rheumatic heart disease. We also reported a significantly higher rate of advanced disease compared with previously published echocardiographic screening programmes.

  4. Evolution of the optical vortex density in phase corrected speckle fields

    CSIR Research Space (South Africa)

    Roux, FS

    2010-09-01

    Full Text Available In an attempt to understand the process whereby the phase modulation due to atmospheric turbulance causes phase singularities (also called optical vortices), the authors investigated the effect of phase perturbations in speckle beams. They perturb...

  5. Speckle interferometry. Data acquisition and control for the SPID instrument.

    Science.gov (United States)

    Altarac, S.; Tallon, M.; Thiebaut, E.; Foy, R.

    1998-08-01

    SPID (SPeckle Imaging by Deconvolution) is a new speckle camera currently under construction at CRAL-Observatoire de Lyon. Its high spectral resolution and high image restoration capabilities open new astrophysical programs. The instrument SPID is composed of four main optical modules which are fully automated and computer controlled by a software written in Tcl/Tk/Tix and C. This software provides an intelligent assistance to the user by choosing observational parameters as a function of atmospheric parameters, computed in real time, and the desired restored image quality. Data acquisition is made by a photon-counting detector (CP40). A VME-based computer under OS9 controls the detector and stocks the data. The intelligent system runs under Linux on a PC. A slave PC under DOS commands the motors. These 3 computers communicate through an Ethernet network. SPID can be considered as a precursor for VLT's (Very Large Telescope, four 8-meter telescopes currently built in Chile by European Southern Observatory) very high spatial resolution camera.

  6. A Nonlinear Diffusion Equation-Based Model for Ultrasound Speckle Noise Removal

    Science.gov (United States)

    Zhou, Zhenyu; Guo, Zhichang; Zhang, Dazhi; Wu, Boying

    2018-04-01

    Ultrasound images are contaminated by speckle noise, which brings difficulties in further image analysis and clinical diagnosis. In this paper, we address this problem in the view of nonlinear diffusion equation theories. We develop a nonlinear diffusion equation-based model by taking into account not only the gradient information of the image, but also the information of the gray levels of the image. By utilizing the region indicator as the variable exponent, we can adaptively control the diffusion type which alternates between the Perona-Malik diffusion and the Charbonnier diffusion according to the image gray levels. Furthermore, we analyze the proposed model with respect to the theoretical and numerical properties. Experiments show that the proposed method achieves much better speckle suppression and edge preservation when compared with the traditional despeckling methods, especially in the low gray level and low-contrast regions.

  7. Which echocardiographic parameter is a better marker of volume status in hemodialysis patients?

    Science.gov (United States)

    Sabaghian, Tahereh; Hajibaratali, Bahareh; Samavat, Shiva

    2016-11-01

    Bio-impedance analysis (BIA) is a preferred method for estimating the volume status. However, it cannot be utilized in daily practice. Since the assessment of the volume status is important and challenging for hemodialysis (HD) patients, the aim of study was to determine the volume status in chronic HD patients using echocardiographic parameters and assess its correlation with BIA. In this cross-sectional analysis, echocardiography and BIA were performed on 30 chronic HD patients 30 min before and 30 min after dialysis. All the cases of dialysis were performed in the middle of the week. This study also assessed the correlation between echocardiographic parameters and BIA parameters. There were significant differences between ECW, TBW, and TBW% (TBW/W) before and after HD. Significant differences were observed between echocardiographic parameters of IVCD, IVCDi min , IVCDi max before and after the HD. LVEDD, LVESD, LA area, mitral valve inflow, E/E', and IVRT, were improved after dialysis, too. There was a significant correlation between IVCDi min as an index of volume status, ECW% and TBW% before HD and IVCDi min change after dialysis had a significant correlation with %ECW change after dialysis. Comparison between hypertensive and non-hypertensive groups indicated IVCDi min was significantly lower in non-hypertensive group after dialysis. Our results showed a correlation between IVCDi min and BIA parameters before HD. So, it seems that IVCDi min can be a good parameter for determining the volume status of HD patients. However, further studies, with larger sample size and with a prospective study design, are required to confirm these results.

  8. A simulation analysis of an extension of one-dimensional speckle correlation method for detection of general in-plane translation

    Czech Academy of Sciences Publication Activity Database

    Hamarová, Ivana; Šmíd, Petr; Horváth, P.; Hrabovský, M.

    2014-01-01

    Roč. 2014, č. 1 (2014), "704368-1"-"704368-12" ISSN 1537-744X R&D Projects: GA ČR GA13-12301S Institutional support: RVO:68378271 Keywords : one-dimensional speckle correlation * speckle * general In-plane translation Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.219, year: 2013

  9. Eleven fetal echocardiographic planes using 4-dimensional ultrasound with spatio-temporal image correlation (STIC): a logical approach to fetal heart volume analysis.

    Science.gov (United States)

    Jantarasaengaram, Surasak; Vairojanavong, Kittipong

    2010-09-15

    Theoretically, a cross-sectional image of any cardiac planes can be obtained from a STIC fetal heart volume dataset. We described a method to display 11 fetal echocardiographic planes from STIC volumes. Fetal heart volume datasets were acquired by transverse acquisition from 200 normal fetuses at 15 to 40 weeks of gestation. Analysis of the volume datasets using the described technique to display 11 echocardiographic planes in the multiplanar display mode were performed offline. Volume datasets from 18 fetuses were excluded due to poor image resolution. The mean visualization rates for all echocardiographic planes at 15-17, 18-22, 23-27, 28-32 and 33-40 weeks of gestation fetuses were 85.6% (range 45.2-96.8%, N = 31), 92.9% (range 64.0-100%, N = 64), 93.4% (range 51.4-100%, N = 37), 88.7%(range 54.5-100%, N = 33) and 81.8% (range 23.5-100%, N = 17) respectively. Overall, the applied technique can favorably display the pertinent echocardiographic planes. Description of the presented method provides a logical approach to explore the fetal heart volumes.

  10. Measurements of 427 Double Stars With Speckle Interferometry: The Winter/Spring 2017 Observing Program at Brilliant Sky Observatory, Part 1

    Science.gov (United States)

    Harshaw, Richard

    2018-04-01

    In the winter and spring of 2017, an aggressive observing program of measuring close double stars with speckle interferometry and CCD imaging was undertaken at Brilliant Sky Observatory, my observing site in Cave Creek, Arizona. A total of 596 stars were observed, 8 of which were rejected for various reasons, leaving 588 pairs. Of these, 427 were observed and measured with speckle interferometry, while the remaining 161 were measured with a CCD. This paper reports the results of the observations of the 427 speckle cases. A separate paper in this issue will report the CCD measurements of the 161 other pairs.

  11. 3-color photometry of a sunspot using speckle masking techniques

    NARCIS (Netherlands)

    Wiehr, E.; Sütterlin, P.

    1998-01-01

    A three-colour photometry is used to deduce the temperature of sunspot fine-structures. Using the Speckle-Masking method for image restoration, the resulting images (one per colour and burst) have a spatial resolution only limited by the telescope's aperture, i.e. 95km (blue), 145 km (red) and

  12. Speckle-based three-dimensional velocity measurement using spatial filtering velocimetry

    DEFF Research Database (Denmark)

    Iversen, Theis Faber Quist; Jakobsen, Michael Linde; Hanson, Steen Grüner

    2011-01-01

    pattern is formed in the observation plane of the imaging system due to reflection from an area of the object illuminated by a coherent light source. The speckle pattern translates in response to in-plane translation of the object, and the presence of an angular offset reference wave coinciding...

  13. Development of an optimized algorithm for the characterization of microflow using speckle patterns present in optical coherence tomography signal; Desenvolvimento de um algoritimo otimizado para caracterizacao de fluxos microfluidicos utilizando padroes de speckle presentes no sinal de tomografia por coerencia optica

    Energy Technology Data Exchange (ETDEWEB)

    Pretto, Lucas Ramos de

    2015-07-01

    This work discusses the Optical Coherence Tomography system (OCT) and its application to the microfluidics area. To this end, physical characterization of microfluidic circuits were performed using 3D (three-dimensional) models constructed from OCT images of such circuits. The technique was thus evaluated as a potential tool to aid in the inspection of microchannels. Going further, this work paper studies and develops analytical techniques for microfluidic flow, in particular techniques based on speckle pattern. In the first instance, existing methods were studied and improved, such as Speckle Variance - OCT, where a gain of 31% was obtained in processing time. Other methods, such as LASCA (Laser Speckle Contrast Analysis), based on speckle autocorrelation, are adapted to OCT images. Derived from LASCA, the developed analysis technique based on intensity autocorrelation motivated the development of a custom OCT system as well as an optimized acquisition software, with a sampling rate of 8 kHz. The proposed method was, then, able to distinguish different flow rates, and limits of detection were tested, proving its feasibility for implementation on Brownian motion analysis and flow rates below 10 μl/min. (author)

  14. Spectral OCT with speckle contrast reduction for evaluation of the healing process after PRK and transepithelial PRK

    OpenAIRE

    Kaluzny, Bartlomiej J.; Szkulmowski, Maciej; Bukowska, Danuta M.; Wojtkowski, Maciej

    2014-01-01

    We evaluate Spectral OCT (SOCT) with a speckle contrast reduction technique using resonant scanner for assessment of corneal surface changes after excimer laser photorefractive keratectomy (PRK) and we compare healing process between conventional PRK and transepithelial PRK. The measurements were performed before and after the surgery. Obtained results show that SOCT with a resonant scanner speckle contrast reduction is capable of providing information regarding the healing process after PRK....

  15. Diameter of the useful diffraction halo in double-exposure speckle photographs recorded under various conditions

    Science.gov (United States)

    Alejo, A.; Marti, L.; Moreno, A.; Ostrovskii, Iu. I.; Serra, R.

    1985-06-01

    Consideration is given to the relationship between the diffraction halo radius Theta(h) and the displacement (Delta) of the object in double exposed speckle photographs taken in various conditions. The numerical values of Theta(h)/Delta were obtained for several speckle recordings having exposure times in the range 0.5-3.8 s. It is shown that long exposure times did not significantly decrease the minimum measureable displacement of the object. The radii of the diffraction halo were the same in the case of both long and short exposure times.

  16. [Early detection of the cardiotoxicity induced by chemotherapy drug through two-dimensional speckle tracking echocardiography combined with high-sensitive cardiac troponin T].

    Science.gov (United States)

    Wang, W; Kang, Y; Shu, X H; Shen, X D; He, B

    2017-11-23

    Objective: To investigate the clinical value of two-dimensional speckle tracking echocardiography(2D-STE) combined with high-sensitive cardiac troponin T (hs-cTnT) in early detection of the cardiotoxicity induced by chemotherapy drug. Methods: Seventy-five non-Hodgkin's lymphoma patients who received the CHOP regimen were recruited in this study. Conventional echocardiography and 2D-STE were performed on these patients before chemotherapy, the second day after the third course of chemotherapy (during chemotherapy) and the second day after the last course of chemotherapy (after chemotherapy). The parameters included left ventricular ejection fraction (LVEF), global longitudinal strain (LS), global circumferential strain (CS) and global radial strain (RS). The serum hs-cTNT levels were tested simultaneously. Results: Three cycles of CHOP were completed in 30 patients and 6-8 cycles of CHOP were completed in 45 patients. The LVEF of 75 patients before, during and after chemotherapy was (63.8±2.6)%, (63.8±2.8)% and (64.0±3.3)%, respectively, without significant difference ( P =0.91). However, the LS of 75 patients before, during and after chemotherapy was (-18.5±1.7)%, (-16.5±1.9)% and (-16.0±1.6)%, respectively. The CS was (-20.9±2.9)%, (-19.3±3.5)% and (-19.2±3.2)%, respectively. The RS was (39.2±6.4)%, (35.3±5.2)% and (35.0±6.2)%, respectively. The hs-cTnT was (0.001 0±0.002 0)ng/ml, (0.006 3±0.008 9)ng/ml and (0.007 3±0.003 8)ng/ml, respectively. The LS, CS and RS were significantly decreased while hs-cTnT was significantly increased during chemotherapy when compared to those before chemotherapy (all of P chemotherapy were marginally different from those during chemotherapy (all of P >0.05). Moreover, T(LS-SD), T(CS-SD) and T(RS-SD) showed no significant difference before, during and after chemotherapy (all of P >0.05). The reduction of LS was positively associated with the enhancement of hs-cTnT after chemotherapy ( r =0.60, P effectively and

  17. Integration of instrumentation and processing software of a laser speckle contrast imaging system

    Science.gov (United States)

    Carrick, Jacob J.

    Laser speckle contrast imaging (LSCI) has the potential to be a powerful tool in medicine, but more research in the field is required so it can be used properly. To help in the progression of Michigan Tech's research in the field, a graphical user interface (GUI) was designed in Matlab to control the instrumentation of the experiments as well as process the raw speckle images into contrast images while they are being acquired. The design of the system was successful and is currently being used by Michigan Tech's Biomedical Engineering department. This thesis describes the development of the LSCI GUI as well as offering a full introduction into the history, theory and applications of LSCI.

  18. Influence of Angiotensin-Converting-Enzyme Gene Polymorphism on Echocardiographic Data of Patients with Ischemic Heart Failure

    Science.gov (United States)

    Duque, Gustavo Salgado; da Silva, Dayse Aparecida; de Albuquerque, Felipe Neves; Schneider, Roberta Siuffo; Gimenez, Alinne; Pozzan, Roberto; Rocha, Ricardo Mourilhe; de Albuquerque, Denilson Campos

    2016-01-01

    Background Association between angiotensin-converting-enzyme (ACE) gene polymorphisms and different clinical and echocardiographic outcomes has been described in patients with heart failure (HF) and coronary artery disease. Studying the genetic profile of the local population with both diseases is necessary to assess the occurrence of that association. Objectives To assess the frequency of ACE gene polymorphisms in patients with ischemic HF in a Rio de Janeiro population, as well as its association with echocardiographic findings. Methods Genetic assessment of I/D ACE polymorphism in association with clinical, laboratory and echocardiographic analysis of 99 patients. Results The allele frequency was: 53 I alleles, and 145 D alleles. Genotype frequencies were: 49.5% DD; 47.48% DI; 3.02% II. Drug treatment was optimized: 98% on beta-blockers, and 84.8% on ACE inhibitors or angiotensin-receptor blocker. Echocardiographic findings: difference between left ventricular diastolic diameters (ΔLVDD) during follow-up: 2.98±8.94 (DD) vs. 0.68±8.12 (DI) vs. -11.0±7.00 (II), p=0.018; worsening during follow-up of the LV systolic diameter (LVSD): 65.3% DD vs. 19.0% DI vs. 0.0% II, p=0.01; of the LV diastolic diameter (LVDD): 65.3% DD vs. 46.8% DI vs. 0.0% II, p=0.03; and of the LV ejection fraction (LVEF): 67.3% DD vs. 40.4% DI vs. 33.3% II, p=0.024. Correlated with D allele: ΔLVEF, ΔLVSD, ΔLVDD. Conclusions More DD genotype patients had worsening of the LVEF, LVSD and LVDD, followed by DI genotype patients, while II genotype patients had the best outcome. The same pattern was observed for ΔLVDD. PMID:27812677

  19. The MUC1 extracellular domain subunit is found in nuclear speckles and associates with spliceosomes.

    Directory of Open Access Journals (Sweden)

    Priyadarsini Kumar

    Full Text Available MUC1 is a large transmembrane glycoprotein and oncogene expressed by epithelial cells and overexpressed and underglycosylated in cancer cells. The MUC1 cytoplasmic subunit (MUC1-C can translocate to the nucleus and regulate gene expression. It is frequently assumed that the MUC1 extracellular subunit (MUC1-N does not enter the nucleus. Based on an unexpected observation that MUC1 extracellular domain antibody produced an apparently nucleus-associated staining pattern in trophoblasts, we have tested the hypothesis that MUC1-N is expressed inside the nucleus. Three different antibodies were used to identify MUC1-N in normal epithelial cells and tissues as well as in several cancer cell lines. The results of immunofluorescence and confocal microscopy analyses as well as subcellular fractionation, Western blotting, and siRNA/shRNA studies, confirm that MUC1-N is found within nuclei of all cell types examined. More detailed examination of its intranuclear distribution using a proximity ligation assay, subcellular fractionation, and immunoprecipitation suggests that MUC1-N is located in nuclear speckles (interchromatin granule clusters and closely associates with the spliceosome protein U2AF65. Nuclear localization of MUC1-N was abolished when cells were treated with RNase A and nuclear localization was altered when cells were incubated with the transcription inhibitor 5,6-dichloro-1-b-d-ribofuranosylbenzimidazole (DRB. While MUC1-N predominantly associated with speckles, MUC1-C was present in the nuclear matrix, nucleoli, and the nuclear periphery. In some nuclei, confocal microscopic analysis suggest that MUC1-C staining is located close to, but only partially overlaps, MUC1-N in speckles. However, only MUC1-N was found in isolated speckles by Western blotting. Also, MUC1-C and MUC1-N distributed differently during mitosis. These results suggest that MUC1-N translocates to the nucleus where it is expressed in nuclear speckles and that MUC1-N and MUC

  20. Impact of revascularization of coronary chronic total occlusion on left ventricular function and electrical stability: analysis by speckle tracking echocardiography and signal-averaged electrocardiogram.

    Science.gov (United States)

    Sotomi, Yohei; Okamura, Atsunori; Iwakura, Katsuomi; Date, Motoo; Nagai, Hiroyuki; Yamasaki, Tomohiro; Koyama, Yasushi; Inoue, Koichi; Sakata, Yasushi; Fujii, Kenshi

    2017-06-01

    The present study aimed to assess the mechanisms of effects of percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) from two different aspects: left ventricular (LV) systolic function assessed by two-dimensional speckle tracking echocardiography (2D-STE) and electrical stability evaluated by late potential on signal-averaged electrocardiogram (SAECG). We conducted a prospective observational study with consecutive CTO-PCI patients. 2D-STE and SAECG were performed before PCI, and after 1-day and 3-months of procedure. 2D-STE computed global longitudinal strain (GLS) and regional longitudinal strain (RLS) in CTO area, collateral blood-supplying donor artery area, and non-CTO/non-donor area. A total of 37 patients (66 ± 11 years, 78% male) were analyzed. RLS in CTO and donor areas and GLS were significantly improved 1-day after the procedure, but these improvements diminished during 3 months. The improvement of RLS in donor area remained significant after 3-months the index procedure (pre-PCI -13.4 ± 4.8% vs. post-3M -15.1 ± 4.5%, P = 0.034). RLS in non-CTO/non-donor area and LV ejection fraction were not influenced. Mitral annulus velocity was improved at 3-month follow-up (5.0 ± 1.4 vs. 5.6 ± 1.7 cm/s, P = 0.049). Before the procedure, 12 patients (35%) had a late potential. All components of the late potential (filtered QRS duration, root-mean-square voltage in the terminal 40 ms, and duration of the low amplitude signal <40 μV) were not improved. CTO-PCI improved RLS in the donor area at 3-month follow-up without changes of LV ejection fraction. Although higher prevalence of late potential in the current population compared to healthy population was observed, late potential as a surrogate of arrhythmogenic substrate was not influenced by CTO-PCI.

  1. Echocardiographic reference ranges for normal left atrial function parameters: results from the EACVI NORRE study.

    Science.gov (United States)

    Sugimoto, Tadafumi; Robinet, Sébastien; Dulgheru, Raluca; Bernard, Anne; Ilardi, Federica; Contu, Laura; Addetia, Karima; Caballero, Luis; Kacharava, George; Athanassopoulos, George D; Barone, Daniele; Baroni, Monica; Cardim, Nuno; Hagendorff, Andreas; Hristova, Krasimira; Lopez, Teresa; de la Morena, Gonzalo; Popescu, Bogdan A; Penicka, Martin; Ozyigit, Tolga; Rodrigo Carbonero, Jose David; van de Veire, Nico; Von Bardeleben, Ralph Stephan; Vinereanu, Dragos; Zamorano, Jose Luis; Go, Yun Yun; Marchetta, Stella; Nchimi, Alain; Rosca, Monica; Calin, Andreea; Moonen, Marie; Cimino, Sara; Magne, Julien; Cosyns, Bernard; Galli, Elena; Donal, Erwan; Habib, Gilbert; Esposito, Roberta; Galderisi, Maurizio; Badano, Luigi P; Lang, Roberto M; Lancellotti, Patrizio

    2018-02-23

    To obtain the normal ranges for echocardiographic measurements of left atrial (LA) function from a large group of healthy volunteers accounting for age and gender. A total of 371 (median age 45 years) healthy subjects were enrolled at 22 collaborating institutions collaborating in the Normal Reference Ranges for Echocardiography (NORRE) study of the European Association of Cardiovascular Imaging (EACVI). Left atrial data sets were analysed with a vendor-independent software (VIS) package allowing homogeneous measurements irrespective of the echocardiographic equipment used to acquire data sets. The lowest expected values of LA function were 26.1%, 48.7%, and 41.4% for left atrial strain (LAS), 2D left atrial emptying fraction (LAEF), and 3D LAEF (reservoir function); 7.7%, 24.2%, and -0.53/s for LAS-active, LAEF-active, and LA strain rate during LA contraction (SRa) (pump function) and 12.0% and 21.6% for LAS-passive and LAEF-passive (conduit function). Left atrial reservoir and conduit function were decreased with age while pump function was increased. All indices of reservoir function and all LA strains had no difference in both gender and vendor. However, inter-vendor differences were observed in LA SRa despite the use of VIS. The NORRE study provides contemporary, applicable echocardiographic reference ranges for LA function. Our data highlight the importance of age-specific reference values for LA functions.

  2. A stepwise composite echocardiographic score predicts severe pulmonary hypertension in patients with interstitial lung disease.

    Science.gov (United States)

    Bax, Simon; Bredy, Charlene; Kempny, Aleksander; Dimopoulos, Konstantinos; Devaraj, Anand; Walsh, Simon; Jacob, Joseph; Nair, Arjun; Kokosi, Maria; Keir, Gregory; Kouranos, Vasileios; George, Peter M; McCabe, Colm; Wilde, Michael; Wells, Athol; Li, Wei; Wort, Stephen John; Price, Laura C

    2018-04-01

    European Respiratory Society (ERS) guidelines recommend the assessment of patients with interstitial lung disease (ILD) and severe pulmonary hypertension (PH), as defined by a mean pulmonary artery pressure (mPAP) ≥35 mmHg at right heart catheterisation (RHC). We developed and validated a stepwise echocardiographic score to detect severe PH using the tricuspid regurgitant velocity and right atrial pressure (right ventricular systolic pressure (RVSP)) and additional echocardiographic signs. Consecutive ILD patients with suspected PH underwent RHC between 2005 and 2015. Receiver operating curve analysis tested the ability of components of the score to predict mPAP ≥35 mmHg, and a score devised using a stepwise approach. The score was tested in a contemporaneous validation cohort. The score used "additional PH signs" where RVSP was unavailable, using a bootstrapping technique. Within the derivation cohort (n=210), a score ≥7 predicted severe PH with 89% sensitivity, 71% specificity, positive predictive value 68% and negative predictive value 90%, with similar performance in the validation cohort (n=61) (area under the curve (AUC) 84.8% versus 83.1%, p=0.8). Although RVSP could be estimated in 92% of studies, reducing this to 60% maintained a fair accuracy (AUC 74.4%). This simple stepwise echocardiographic PH score can predict severe PH in patients with ILD.

  3. Local scattering property scales flow speed estimation in laser speckle contrast imaging

    International Nuclear Information System (INIS)

    Miao, Peng; Chao, Zhen; Feng, Shihan; Ji, Yuanyuan; Yu, Hang; Thakor, Nitish V; Li, Nan

    2015-01-01

    Laser speckle contrast imaging (LSCI) has been widely used in in vivo blood flow imaging. However, the effect of local scattering property (scattering coefficient µ s ) on blood flow speed estimation has not been well investigated. In this study, such an effect was quantified and involved in relation between speckle autocorrelation time τ c and flow speed v based on simulation flow experiments. For in vivo blood flow imaging, an improved estimation strategy was developed to eliminate the estimation bias due to the inhomogeneous distribution of the scattering property. Compared to traditional LSCI, a new estimation method significantly suppressed the imaging noise and improves the imaging contrast of vasculatures. Furthermore, the new method successfully captured the blood flow changes and vascular constriction patterns in rats’ cerebral cortex from normothermia to mild and moderate hypothermia. (letter)

  4. Implementation of the stress echocardiography in an echocardiographic laboratory

    International Nuclear Information System (INIS)

    Solis Brizuela, Felix

    2013-01-01

    The logistics for the implementation of the stress echocardiography is defined with based on current recommendations, for an echocardiography laboratory. The protocols established to perform the studies and procedures of this diagnostic method are exposed. The elementary conditions to realize with safety the stress echocardiography are established. Recent literature on the evaluation of new echocardiographic techniques is reviewed to determine their usefulness in stress testing. The assessment of stress echocardiography is developed. The stress echocardiography has been the procedure with high sensitivity and specificity for the diagnosis of coronary artery disease [es

  5. Echocardiographic Assessment of Pulmonary Arterial Hypertension for Pediatricians and Neonatologists

    Directory of Open Access Journals (Sweden)

    Gregory James Skinner

    2017-09-01

    Full Text Available There is a growing awareness of the role that increased pulmonary vascular resistance (PVR plays in many pathologies; therefore, assessment of pulmonary artery pressure (PAP is an increasingly requested investigation in the critical care environment. This article will go through the basic concepts regarding PAP and PVR, then will go on to outline the various echocardiographic parameters which are used to assess them. Finally, an outline of how to undertake this assessment will be presented.

  6. The effects of detomidine, romifidine or acepromazine on echocardiographic measurements and cardiac function in normal horses.

    Science.gov (United States)

    Buhl, Rikke; Ersbøll, Annette K; Larsen, Nanna H; Eriksen, Lis; Koch, Jørgen

    2007-01-01

    To evaluate by echo- and electrocardiography the cardiac effects of sedation with detomidine hydrochloride, romifidine hydrochloride or acepromazine maleate in horses. An experimental study using a cross-over design without randomization. Eight clinically normal Standardbred trotters. Echocardiographic examinations (two-dimensional, guided M-mode and colour Doppler) were recorded on five different days. Heart rate (HR) and standard limb lead electrocardiograms were also obtained. Subsequently, horses were sedated with detomidine (0.01 mg kg(-1)), romifidine (0.04 mg kg(-1)) or acepromazine (0.1 mg kg(-1)) administered intravenously and all examinations repeated. Heart rate before treatment with the three drugs did not differ significantly (p = 0.98). Both detomidine and romifidine induced a significant decrease (p detomidine, there was a significant increase in LVIDd (left ventricular internal diameter in diastole; p = 0.034) and LVIDs (left ventricular internal diameter in systole; p detomidine and to a lesser extent romifidine at the doses given in this study has a significant effect on heart function, echocardiographic measurements of heart dimensions and the occurrence of valvular regurgitation. Although the clinical significance of these results may be minimal, the potential effects of sedative drugs should be taken into account when echocardiographic variables are interpreted in clinical cases.

  7. Second-order oriented partial-differential equations for denoising in electronic-speckle-pattern interferometry fringes.

    Science.gov (United States)

    Tang, Chen; Han, Lin; Ren, Hongwei; Zhou, Dongjian; Chang, Yiming; Wang, Xiaohang; Cui, Xiaolong

    2008-10-01

    We derive the second-order oriented partial-differential equations (PDEs) for denoising in electronic-speckle-pattern interferometry fringe patterns from two points of view. The first is based on variational methods, and the second is based on controlling diffusion direction. Our oriented PDE models make the diffusion along only the fringe orientation. The main advantage of our filtering method, based on oriented PDE models, is that it is very easy to implement compared with the published filtering methods along the fringe orientation. We demonstrate the performance of our oriented PDE models via application to two computer-simulated and experimentally obtained speckle fringes and compare with related PDE models.

  8. Echocardiographic findings and joint hypermobility: patients with mitral valve prolapse vs. healthy controls

    Directory of Open Access Journals (Sweden)

    Moradmand S

    2008-11-01

    Full Text Available "nBackground: Mitral valve prolapse is a relatively common valvular abnormality in most communities and joint hypermobility (JHM is also seen in many healthy people as well as in certain clinical disorders, such as Marfan syndrome. The present study was designed to investigate the association between joint hypermobility and mitral valve prolapse (MVP in an Iranian population sample. "nMethods: Fifty-seven patients with nonrheumatic and isolated mitral anterior leaflet prolapse (24 men and 33 women, mean age 23.5 +/-2.3 and 51 healthy subjects (20 men and 31 women, mean age 22.9+/-2.3 were studied. The presence of JHM was evaluated according to the Carter-Wilkinson & Beighton criteria. Echocardiographic examination was performed in all subjects and the correlation between the echocardiographic features of the mitral valve and the hypermobility score were investigated. "nResults: The frequency of JHM in patients with MVP was found to be significantly higher than that of controls (26.3% vs. 7.8%, with mean JHM scores of 3.1+/-2.2 and 1.9+/-1.7, respectively. The patients in the MVP group had significantly increased the anterior mitral leaflet thickness (AMLT, 3.4+/-0.4 mm vs. 3.0+/-0.3 mm; p<0.0005 and maximal leaflet displacement (MLD, 2.4+/-0.3 mm vs. 1.5+/-0.2 mm; p<0.0005 compared to the controls. "nConclusions: We detect a statistically significant relationship between isolated MVP and joint hypermobility as well as between the severity of JHM and echocardiographic features of the mitral leaflets. These results suggest a common etiology for MVP and JHM, which should be investigated in future well-conducted studies.

  9. A Novel Sub-pixel Measurement Algorithm Based on Mixed the Fractal and Digital Speckle Correlation in Frequency Domain

    Directory of Open Access Journals (Sweden)

    Zhangfang Hu

    2014-10-01

    Full Text Available The digital speckle correlation is a non-contact in-plane displacement measurement method based on machine vision. Motivated by the facts that the low accuracy and large amount of calculation produced by the traditional digital speckle correlation method in spatial domain, we introduce a sub-pixel displacement measurement algorithm which employs a fast interpolation method based on fractal theory and digital speckle correlation in frequency domain. This algorithm can overcome either the blocking effect or the blurring caused by the traditional interpolation methods, and the frequency domain processing also avoids the repeated searching in the correlation recognition of the spatial domain, thus the operation quantity is largely reduced and the information extracting speed is improved. The comparative experiment is given to verify that the proposed algorithm in this paper is effective.

  10. Laser speckle velocimetry for robot manufacturing

    Science.gov (United States)

    Charrett, Thomas O. H.; Bandari, Yashwanth K.; Michel, Florent; Ding, Jialuo; Williams, Stewart W.; Tatam, Ralph P.

    2017-06-01

    A non-contact speckle correlation sensor for the measurement of robotic tool speed is presented for use in robotic manufacturing and is capable of measuring the in-plane relative velocities between a robot end-effector and the workpiece or other surface. The sensor performance was assessed in the laboratory with the sensor accuracies found to be better than 0:01 mm/s over a 70 mm/s velocity range. Finally an example of the sensors application to robotic manufacturing is presented where the sensor was applied to tool speed measurement for path planning in the wire and arc additive manufacturing process using a KUKA KR150 L110/2 industrial robot.

  11. Developments In Electronic Speckle Pattern Interferometry For Automotive Vibration Analysis.

    Science.gov (United States)

    Davies, Jeremy C.; Buckberry, Clive H.; Jones, Julian D. C.; Pannell, Chris N.

    1989-01-01

    The incorporation of monomode fibre optics into an argon ion powered Electronic Speckle Pattern Interferometer (ESPI) is reported. The system, consisting of an optics assembly linked to the laser and a CCD camera transceiver, flexibly connected by 40m of monomode fibre optic cable to the optics, has been used to analyse the modal behaviour of structures up to 5m X 3m X 2m in size. Phase modulation of the reference beam in order to operate in a heterodyne mode has been implemented using a piezo-electric crystal operating on the monomode fibre. A new mode of operation - sequential time-average subtraction - and the results of a new processing algorithm are also reported. Their implementation enables speckle free, time-average vibration maps to be generated in real-time on large, unstable structures. Example results for a four cylinder power unit, a vehicle body shell component and an engine oil pan are included. In all cases the analysis was conducted in a general workshop environment without the need for vibration isolation facilities.

  12. Laser speckle velocimetry applied to Rayleigh-Benard convection

    International Nuclear Information System (INIS)

    Arroyo, M.P.; Yonte, T.; Quintanilla, M.; Saviron, J.M.

    1986-01-01

    An application of speckle velocimetry technique to Rayleigh-Benard convection is presented. A 5-mW He-Ne laser allows precise determination of the two-dimensional velocity flow field, up to several mm/sec. The digital techniques used to analyze automatically the multiexposed photographs and to generate velocity and vorticity fields are described. The obtained results are in good agreement with previously reported data. The ability of the technique to cover other experimental conditions is discussed. 14 references

  13. Lensless Photoluminescence Hyperspectral Camera Employing Random Speckle Patterns.

    Czech Academy of Sciences Publication Activity Database

    Žídek, Karel; Denk, Ondřej; Hlubuček, Jiří

    2017-01-01

    Roč. 7, č. 1 (2017), č. článku 15309. ISSN 2045-2322 R&D Projects: GA MŠk(CZ) LO1206; GA ČR(CZ) GJ17-26284Y Institutional support: RVO:61389021 Keywords : compressed sensing * photoluminescence imaging * laser speckles * single-pixel camera Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 4.259, year: 2016 https://www.nature.com/articles/s41598-017-14443-4

  14. Echocardiographic and radiographic findings in a cohort of healthy adult green iguanas (Iguana iguana).

    Science.gov (United States)

    Gustavsen, Kate A; Saunders, Ashley B; Young, Benjamin D; Winter, Randolph L; Hoppes, Sharman M

    2014-09-01

    To describe characteristics of echocardiography and cranial coelomic radiography in a cohort of iguanas. Twenty apparently healthy adult green iguanas (Iguana iguana) from a reptile sanctuary. Physical examination, radiography, two-dimensional and color Doppler echocardiography were performed to assess cardiac structures and function, and any related normal or abnormal findings were recorded. Echocardiographic examination was possible without sedation and allowed visualization of the great vessels, atria, and ventricle. Some structures could not be evaluated in a minority of the iguanas due to individual differences in bony conformation and imaging quality. Suspected abnormal echocardiographic findings in 3 iguanas included pericardial effusion (n = 1) and enlarged caudal vena cava and/or sinus venosus (n = 2). Objective measurements were repeatable as assessed by within-subject coefficient of variation, and reliable as assessed by intra-observer intraclass correlation coefficient. Left atrial and ventricular measurements were significantly correlated with body weight. Valve regurgitation was common, with atrioventricular valve regurgitation present in 53% (9/17) and aortic or pulmonic valve regurgitation in 71% (12/17) of otherwise normal iguanas. A heart murmur was not appreciated during examination of any of the iguanas. Heart size cannot be measured radiographically due to superimposition and silhouetting of other coelomic structures. Echocardiographic or radiographic findings consistent with mineralization of the great vessels were present in 76% of iguanas (13/17). Echocardiography in iguanas is well tolerated without sedation and allowed both subjective evaluation and structural measurements. Valve regurgitation and great vessel mineralization were commonly observed in this cohort of apparently healthy adult iguanas. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Impact of atmospheric turbulence on Van Cittert-Zernike speckle cell area estimates

    International Nuclear Information System (INIS)

    Morris, J.R.

    1995-01-01

    Simulations of laser beam propagation at 3.5 microns wavelength through atmospheric turbulence are used to characterize on-target irradiance profiles and the Van Cittert-Zemike speckle cell areas associated therewith. Results for a 3 km horizontal path with C N 2 values between 2.5 x 10 -14 and 5 x 10 -13 m -2/3 are compared with those for a 20 km near-vertical slant path for a C N 2 versus altitude with a near-ground value of 5 x 10 --13 m -2/3 and a Huffnagel-Valley type shape. The irradiance fluctuations for the slant path are much smaller than for the shorter horizontal path. The speckle cell area for the slant path is approximately the vacuum-path value; for the 3 km horizontal path it is at most 3 times the vacuum-path value

  16. Incidence of mitral valve prolapse in one hundred clinically stable newborn baby girls: an echocardiographic study.

    Science.gov (United States)

    Chandraratna, P A; Vlahovich, G; Kong, Y; Wilson, D

    1979-09-01

    Clinical and echocardiographic examinations were performed on 100 clinically stable, newborn baby girls. Mitral valve prolapse was noted on the echocardiograms of seven babies. Three subjects had systolic clicks, two of whom had systolic murmurs following the click. The four other babies who had echocardiographic evidence of mitral valve prolapse had no abnormal auscultatory signs. Of the 93 babies without evidence of mitral prolapse, 91 had normal echocardiograms and auscultatory features; one was noted to have a murmur consistent with a ventricular septal defect, and another had an eccentric aortic valve on the echocardiogram which was suggestive of a bicuspid aortic valve. Serial studies on our group of subjects will yield useful information regarding the natural history of mitral valve prolapse.

  17. A Study on Residual Stress Measurements by Using Laser Speckle Interferometry

    International Nuclear Information System (INIS)

    Rho, Kyung Wan; Kang, Young June; Hong, Seong Jin; Kang, Hyung Soo

    1999-01-01

    Residual stress is one of the causes which make defects in engineering components and materials. And interest in the measurement of residual stress exists in many industries. There are commonly used methods by which residual stresses are currently measured. But these methods have a little demerits: time consumption and other problems. Therefore we devised a new experimental technique to measure residual stress in materials with a combination of laser speckle pattern interferometry, finite element method and spot heating. The speckle pattern interferometer measures in-plane deformations while the heating provides for very localized stress relief. FEM is used for determining heat temperature and other parameters. The residual stresses are determined by the amount of strain that is measured subsequent to the heating and cool-down of the region being interrogated. A simple model is presented to provide a description of the method. In this paper, the ambiguity problem for the fringe patterns has solved by a phase shifting method

  18. Development of an optimized algorithm for the characterization of microflow using speckle patterns present in optical coherence tomography signal

    International Nuclear Information System (INIS)

    Pretto, Lucas Ramos de

    2015-01-01

    This work discusses the Optical Coherence Tomography system (OCT) and its application to the microfluidics area. To this end, physical characterization of microfluidic circuits were performed using 3D (three-dimensional) models constructed from OCT images of such circuits. The technique was thus evaluated as a potential tool to aid in the inspection of microchannels. Going further, this work paper studies and develops analytical techniques for microfluidic flow, in particular techniques based on speckle pattern. In the first instance, existing methods were studied and improved, such as Speckle Variance - OCT, where a gain of 31% was obtained in processing time. Other methods, such as LASCA (Laser Speckle Contrast Analysis), based on speckle autocorrelation, are adapted to OCT images. Derived from LASCA, the developed analysis technique based on intensity autocorrelation motivated the development of a custom OCT system as well as an optimized acquisition software, with a sampling rate of 8 kHz. The proposed method was, then, able to distinguish different flow rates, and limits of detection were tested, proving its feasibility for implementation on Brownian motion analysis and flow rates below 10 μl/min. (author)

  19. Echocardiographic Screening of Rheumatic Heart Disease in American Samoa.

    Science.gov (United States)

    Huang, Jennifer H; Favazza, Michael; Legg, Arthur; Holmes, Kathryn W; Armsby, Laurie; Eliapo-Unutoa, Ipuniuesea; Pilgrim, Thomas; Madriago, Erin J

    2018-01-01

    While rheumatic heart disease (RHD) is a treatable disease nearly eradicated in the United States, it remains the most common form of acquired heart disease in the developing world. This study used echocardiographic screening to determine the prevalence of RHD in children in American Samoa. Screening took place at a subset of local schools. Private schools were recruited and public schools underwent cluster randomization based on population density. We collected survey information and performed a limited physical examination and echocardiogram using the World Heart Federation protocol for consented school children aged 5-18 years old. Of 2200 students from two private high schools and two public primary schools, 1058 subjects consented and were screened. Overall, 133 (12.9%) children were identified as having either definite (3.5%) or borderline (9.4%) RHD. Of the patients with definitive RHD, 28 subjects had abnormal mitral valves with pathologic regurgitation, three mitral stenosis, three abnormal aortic valves with pathologic regurgitation, and seven borderline mitral and aortic valve disease. Of the subjects with borderline disease, 77 had pathologic mitral regurgitation, 12 pathologic aortic regurgitation, and 7 at least two features of mitral valve disease without pathologic regurgitation or stenosis. Rheumatic heart disease remains a major cause of morbidity and mortality worldwide. The prevalence of RHD in American Samoa (12.9%) is to date the highest reported in the world literature. Echocardiographic screening of school children is feasible, while reliance on murmur and Jones criteria is not helpful in identifying children with RHD.

  20. Can echocardiographic findings predict falls in older persons?

    Directory of Open Access Journals (Sweden)

    Nathalie van der Velde

    Full Text Available BACKGROUND: The European and American guidelines state the need for echocardiography in patients with syncope. 50% of older adults with syncope present with a fall. Nonetheless, up to now no data have been published addressing echocardiographic abnormalities in older fallers. METHOD AND FINDINGS: In order to determine the association between echocardiographic abnormalities and falls in older adults, we performed a prospective cohort study, in which 215 new consecutive referrals (age 77.4, SD 6.0 of a geriatric outpatient clinic of a Dutch university hospital were included. During the previous year, 139 had experienced a fall. At baseline, all patients underwent routine two-dimensional and Doppler echocardiography. Falls were recorded during a three-month follow-up. Multivariate adjustment for confounders was performed with a Cox proportional hazards model. 55 patients (26% fell at least once during follow-up. The adjusted hazard ratio of a fall during follow-up was 1.35 (95% CI, 1.08-1.71 for pulmonary hypertension, 1.66 (95% CI, 1.01 to 2.89 for mitral regurgitation, 2.41 (95% CI, 1.32 to 4.37 for tricuspid regurgitation and 1.76 (95% CI, 1.03 to 3.01 for pulmonary regurgitation. For aortic regurgitation the risk of a fall was also increased, but non-significantly (hazard ratio, 1.57 [95% CI, 0.85 to 2.92]. Trend analysis of the severity of the different regurgitations showed a significant relationship for mitral, tricuspid and pulmonary valve regurgitation and pulmonary hypertension. CONCLUSIONS: Echo (Doppler cardiography can be useful in order to identify risk indicators for falling. Presence of pulmonary hypertension or regurgitation of mitral, tricuspid or pulmonary valves was associated with a higher fall risk. Our study indicates that the diagnostic work-up for falls in older adults might be improved by adding an echo (Doppler cardiogram in selected groups.

  1. 3D polarisation speckle as a demonstration of tensor version of the van Cittert-Zernike theorem for stochastic electromagnetic beams

    Science.gov (United States)

    Ma, Ning; Zhao, Juan; Hanson, Steen G.; Takeda, Mitsuo; Wang, Wei

    2016-10-01

    Laser speckle has received extensive studies of its basic properties and associated applications. In the majority of research on speckle phenomena, the random optical field has been treated as a scalar optical field, and the main interest has been concentrated on their statistical properties and applications of its intensity distribution. Recently, statistical properties of random electric vector fields referred to as Polarization Speckle have come to attract new interest because of their importance in a variety of areas with practical applications such as biomedical optics and optical metrology. Statistical phenomena of random electric vector fields have close relevance to the theories of speckles, polarization and coherence theory. In this paper, we investigate the correlation tensor for stochastic electromagnetic fields modulated by a depolarizer consisting of a rough-surfaced retardation plate. Under the assumption that the microstructure of the scattering surface on the depolarizer is as fine as to be unresolvable in our observation region, we have derived a relationship between the polarization matrix/coherency matrix for the modulated electric fields behind the rough-surfaced retardation plate and the coherence matrix under the free space geometry. This relation is regarded as entirely analogous to the van Cittert-Zernike theorem of classical coherence theory. Within the paraxial approximation as represented by the ABCD-matrix formalism, the three-dimensional structure of the generated polarization speckle is investigated based on the correlation tensor, indicating a typical carrot structure with a much longer axial dimension than the extent in its transverse dimension.

  2. Suppressed speckle contrast of blue light emission out of white lamp with phosphors excited by blue laser diodes for high-brightness lighting applications

    Science.gov (United States)

    Kinoshita, Junichi; Ikeda, Yoshihisa; Takeda, Yuji; Ueno, Misaki; Kawasaki, Yoji; Matsuba, Yoshiaki; Heike, Atsushi

    2012-11-01

    The speckle contrast of blue light emission out of high-brightness white lamps using phosphors excited by InGaN/GaN blue laser diodes is evaluated as a measure of coherence. As a result, speckle contrast of as low as 1.7%, the same level as a blue light emitting diode, is obtained. This implies that the original blue laser light can be converted into incoherent light through lamp structures without any dynamic mechanisms. This unique speckle-free performance is considered to be realized by multiple scattering inside the lamp structure, the multi-longitudinal mode operation of the blue laser diodes, and the use of multiple laser diodes. Such almost-incoherent white lamps can be applied for general lighting without any nuisance of speckle noise and should be categorized as lamps rather than lasers in terms of laser safety regulation.

  3. Diagnostic Value of Selected Echocardiographic Variables to Identify Pulmonary Hypertension in Dogs with Myxomatous Mitral Valve Disease.

    Science.gov (United States)

    Tidholm, A; Höglund, K; Häggström, J; Ljungvall, I

    2015-01-01

    Pulmonary hypertension (PH) is commonly associated with myxomatous mitral valve disease (MMVD). Because dogs with PH present without measureable tricuspid regurgitation (TR), it would be useful to investigate echocardiographic variables that can identify PH. To investigate associations between estimated systolic TR pressure gradient (TRPG) and dog characteristics and selected echocardiographic variables. 156 privately owned dogs. Prospective observational study comparing the estimations of TRPG with dog characteristics and selected echocardiographic variables in dogs with MMVD and measureable TR. Tricuspid regurgitation pressure gradient was significantly (P modeled as linear variables LA/Ao (P modeled as second order polynomial variables: AT/DT (P = .0039) and LVIDDn (P value for the final model was 0.45 and receiver operating characteristic curve analysis suggested the model's performance to predict PH, defined as 36, 45, and 55 mmHg as fair (area under the curve [AUC] = 0.80), good (AUC = 0.86), and excellent (AUC = 0.92), respectively. In dogs with MMVD, the presence of PH might be suspected with the combination of decreased PA AT/DT, increased RVIDDn and LA/Ao, and a small or great LVIDDn. Copyright © 2015 The Authors Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  4. Laser speckle imaging of rat retinal blood flow with hybrid temporal and spatial analysis method

    Science.gov (United States)

    Cheng, Haiying; Yan, Yumei; Duong, Timothy Q.

    2009-02-01

    Noninvasive monitoring of blood flow in retinal circulation will reveal the progression and treatment of ocular disorders, such as diabetic retinopathy, age-related macular degeneration and glaucoma. A non-invasive and direct BF measurement technique with high spatial-temporal resolution is needed for retinal imaging. Laser speckle imaging (LSI) is such a method. Currently, there are two analysis methods for LSI: spatial statistics LSI (SS-LSI) and temporal statistical LSI (TS-LSI). Comparing these two analysis methods, SS-LSI has higher signal to noise ratio (SNR) and TSLSI is less susceptible to artifacts from stationary speckle. We proposed a hybrid temporal and spatial analysis method (HTS-LSI) to measure the retinal blood flow. Gas challenge experiment was performed and images were analyzed by HTS-LSI. Results showed that HTS-LSI can not only remove the stationary speckle but also increase the SNR. Under 100% O2, retinal BF decreased by 20-30%. This was consistent with the results observed with laser Doppler technique. As retinal blood flow is a critical physiological parameter and its perturbation has been implicated in the early stages of many retinal diseases, HTS-LSI will be an efficient method in early detection of retina diseases.

  5. Allometric scaling of echocardiographic measurements in healthy Spanish foals with different body weight.

    Science.gov (United States)

    Rovira, S; Muñoz, A; Rodilla, V

    2009-04-01

    Scaling in biology is usually allometric, and therefore, the size of the heart may be expressed as a power function of body weight (BW). The present research analyses the echocardiographic measurements in 68 healthy Spanish foals weighed between 70 and 347kg in order to determine the correct scaling exponent for the allometric equation. The echocardiographic parameters measured were: left ventricular internal dimensions (LVID), free wall thickness (LVFWT), interventricular septum thickness (IVST) at systole (s) and diastole (d), EPSS (distance between the point E of the mitral valve and the interventricular septum), and aorta diameters at the level of the aortic valve (AOD), base of valve leaflets (ABS), sinus of Valsalva (ASV) and sino-tubular junction (AJT). Indices of left ventricular performance were calculated. It was found that LVIDd, IVSTs, AOD, and ASV have a relationship to BW raised to 0.300-0.368 power, whereas left ventricular end-diastolic volume and stroke volume scaled to BW raised to 0.731-0.712 power. With these data, appropriate values can be calculated for normal Spanish foals.

  6. Correlation analysis of the relationship between B-type natriuretic peptide and selected echocardiographic parameters in patients with permanent pacemakers

    Directory of Open Access Journals (Sweden)

    Janusz Sielski

    2016-01-01

    Full Text Available Introduction: The present study was undertaken to evaluate the practical value of BNP measurements and echocardiographic left ventricular volume index in patients with permanent pacemakers because there are no such reports in the literature. Aim of the research: The aim of the study was to reveal multiple correlations between BNP levels and selected echocardiographic parameters of the left atrium in patients with permanent pacemakers. In the literature there are reports on the significance of BNP values and left atrial size in patients with permanent pacemakers. The results of the present study appear to be of value in the outpatient assessment of these patients. Material and methods: We analysed a group of 117 patients with permanent pacemakers (AAI/R 21 patients, DDD/R 59 patients, VVI/R 37 patients and 48 healthy volunteers serving as the control group. BNP measurements were performed on venous blood samples using Triage meters. The Simpson method and the ellipse method were used to assess the left atrium on echocardiography. Results: There was a significant correlation between BNP and maximum left atrial volume, minimum left atrial volume, and left atrial volume index in patients with AAI/R, DDD/R, and VVI/R pacemakers at 3 and 6 months after the implantation. Conclusions : In patients after implantation of permanent pacemakers there are correlations between BNP values and echocardiographic left atrial parameters, especially in patients with DDD/R pacemakers. Left atrial function improves in patients with DDD/R pacemakers. Pacemaker check-up should be extended to include BNP measurements and echocardiographic assessment of the left atrium.

  7. Intraoperative Hemodynamic and Echocardiographic Measurements Associated With Severe Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Gudejko, Michael D; Gebhardt, Brian R; Zahedi, Farhad; Jain, Ankit; Breeze, Janis L; Lawrence, Matthew R; Shernan, Stanton K; Kapur, Navin K; Kiernan, Michael S; Couper, Greg; Cobey, Frederick C

    2018-06-05

    Severe right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation increases morbidity and mortality. We investigated the association between intraoperative right heart hemodynamic data, echocardiographic parameters, and severe versus nonsevere RVF. A review of LVAD patients between March 2013 and March 2016 was performed. Severe RVF was defined by the need for a right ventricular mechanical support device, inotropic, and/or inhaled pulmonary vasodilator requirements for >14 days. From a chart review, the right ventricular failure risk score was calculated and right heart hemodynamic data were collected. Pulmonary artery pulsatility index (PAPi) [(pulmonary artery systolic pressure - pulmonary artery diastolic pressure)/central venous pressure (CVP)] was calculated for 2 periods: (1) 30 minutes before cardiopulmonary bypass (CPB) and (2) after chest closure. Echocardiographic data were recorded pre-CPB and post-CPB by a blinded reviewer. Univariate logistic regression models were used to examine the performance of hemodynamic and echocardiographic metrics. A total of 110 LVAD patients were identified. Twenty-five did not meet criteria for RVF. Of the remaining 85 patients, 28 (33%) met criteria for severe RVF. Hemodynamic factors associated with severe RVF included: higher CVP values after chest closure (18 ± 9 vs 13 ± 5 mm Hg; P = .0008) in addition to lower PAPi pre-CPB (1.2 ± 0.6 vs 1.7 ± 1.0; P = .04) and after chest closure (0.9 ± 0.5 vs 1.5 ± 0.8; P = .0008). Post-CPB echocardiographic findings associated with severe RVF included: larger right atrial diameter major axis (5.4 ± 0.9 vs 4.9 ± 1.0 cm; P = .03), larger right ventricle end-systolic area (22.6 ± 8.4 vs 18.5 ± 7.9 cm; P = .03), lower fractional area of change (20.2 ± 10.8 vs 25.9 ± 12.6; P = .04), and lower tricuspid annular plane systolic excursion (0.9 ± 0.2 vs 1.1 ± 0.3 cm; P = .008). Right ventricular failure risk score was not a significant predictor of

  8. Early Cardiac Involvement Affects Left Ventricular Longitudinal Function in Females Carrying α-Galactosidase A Mutation: Role of Hybrid Positron Emission Tomography and Magnetic Resonance Imaging and Speckle-Tracking Echocardiography.

    Science.gov (United States)

    Spinelli, Letizia; Imbriaco, Massimo; Nappi, Carmela; Nicolai, Emanuele; Giugliano, Giuseppe; Ponsiglione, Andrea; Diomiaiuti, Tommaso Claudio; Riccio, Eleonora; Duro, Giovanni; Pisani, Antonio; Trimarco, Bruno; Cuocolo, Alberto

    2018-04-01

    Hybrid 18 F-fluorodeoxyglucose (FDG) positron emission tomography and magnetic resonance imaging may differentiate mature fibrosis or scar from fibrosis associated to active inflammation in patients with Anderson-Fabry disease, even in nonhypertrophic stage. This study was designed to compare the results of positron emission tomography and magnetic resonance cardiac imaging with those of speckle-tracking echocardiography in heterozygous Anderson-Fabry disease females. Twenty-four heterozygous females carrying α-galactosidase A mutation and without left ventricular hypertrophy underwent cardiac positron emission tomography and magnetic resonance using 18 F-FDG for glucose uptake and 2-dimensional strain echocardiography. 18 F-FDG myocardial uptake was quantified by measuring the coefficient of variation (COV) of the standardized uptake value using a 17-segment model. Focal 18 F-FDG uptake with COV >0.17 was detected in 13 patients, including 2 patients with late gadolinium enhancement at magnetic resonance. COV was 0.30±0.14 in patients with focal 18 F-FDG uptake and 0.12±0.03 in those without ( P 0.17 compared with those with COV ≤0.17 (-18.5±2.7% versus -22.2±1.8%; P =0.024). For predicting COV >0.17, a global longitudinal strain >-19.8% had 77% sensitivity and 91% specificity and a value >2 dysfunctional segments 92% sensitivity and 100% specificity. In females carrying α-galactosidase A mutation, focal 18 F-FDG uptake represents an early sign of disease-related myocardial damage and is associated with impaired left ventricular longitudinal function. These findings support the hypothesis that inflammation plays an important role in glycosphingolipids storage disorders. © 2018 American Heart Association, Inc.

  9. Application of virtual phase-shifting speckle-interferometry for detection of polymorphism in the Chlamydia trachomatis omp1 gene

    Science.gov (United States)

    Feodorova, Valentina A.; Saltykov, Yury V.; Zaytsev, Sergey S.; Ulyanov, Sergey S.; Ulianova, Onega V.

    2018-04-01

    Method of phase-shifting speckle-interferometry has been used as a new tool with high potency for modern bioinformatics. Virtual phase-shifting speckle-interferometry has been applied for detection of polymorphism in the of Chlamydia trachomatis omp1 gene. It has been shown, that suggested method is very sensitive to natural genetic mutations as single nucleotide polymorphism (SNP). Effectiveness of proposed method has been compared with effectiveness of the newest bioinformatic tools, based on nucleotide sequence alignment.

  10. Measurement of natural convection by speckle photography

    International Nuclear Information System (INIS)

    Wernekinck, U.; Merzkirch, W.

    1986-01-01

    The principle of speckle photography can be applied to the measurement of density variations in fluids. A modification of existing experimental arrangements allows for the measurement of large values of the light deflection angles as they may occur in heat and mass transfer situations. The method is demonstrated for the case of a helium jet exhausting into still air and the natural convective flow along a heated plate. The obtained data are compared with results measured with classical optical interferometers, and good agreement is found. The advantages of the new technique over the classical optical methods are briefly discussed. 11 references

  11. Surface modeling method for aircraft engine blades by using speckle patterns based on the virtual stereo vision system

    Science.gov (United States)

    Yu, Zhijing; Ma, Kai; Wang, Zhijun; Wu, Jun; Wang, Tao; Zhuge, Jingchang

    2018-03-01

    A blade is one of the most important components of an aircraft engine. Due to its high manufacturing costs, it is indispensable to come up with methods for repairing damaged blades. In order to obtain a surface model of the blades, this paper proposes a modeling method by using speckle patterns based on the virtual stereo vision system. Firstly, blades are sprayed evenly creating random speckle patterns and point clouds from blade surfaces can be calculated by using speckle patterns based on the virtual stereo vision system. Secondly, boundary points are obtained in the way of varied step lengths according to curvature and are fitted to get a blade surface envelope with a cubic B-spline curve. Finally, the surface model of blades is established with the envelope curves and the point clouds. Experimental results show that the surface model of aircraft engine blades is fair and accurate.

  12. Simultaneous acquisition of 3D shape and deformation by combination of interferometric and correlation-based laser speckle metrology.

    Science.gov (United States)

    Dekiff, Markus; Berssenbrügge, Philipp; Kemper, Björn; Denz, Cornelia; Dirksen, Dieter

    2015-12-01

    A metrology system combining three laser speckle measurement techniques for simultaneous determination of 3D shape and micro- and macroscopic deformations is presented. While microscopic deformations are determined by a combination of Digital Holographic Interferometry (DHI) and Digital Speckle Photography (DSP), macroscopic 3D shape, position and deformation are retrieved by photogrammetry based on digital image correlation of a projected laser speckle pattern. The photogrammetrically obtained data extend the measurement range of the DHI-DSP system and also increase the accuracy of the calculation of the sensitivity vector. Furthermore, a precise assignment of microscopic displacements to the object's macroscopic shape for enhanced visualization is achieved. The approach allows for fast measurements with a simple setup. Key parameters of the system are optimized, and its precision and measurement range are demonstrated. As application examples, the deformation of a mandible model and the shrinkage of dental impression material are measured.

  13. Predictors of Total Mortality and Echocardiographic Response for Cardiac Resynchronization Therapy: A Cohort Study

    Directory of Open Access Journals (Sweden)

    Guilherme Ferreira Gazzoni

    2017-11-01

    Full Text Available Abstract Background: Clinical studies demonstrate that up to 40% of patients do not respond to cardiac resynchronization therapy (CRT, thus, appropriate patient selection is critical to the success of CRT in heart failure. Objective: Evaluation of mortality predictors and response to CRT in the Brazilian scenario. Methods: Retrospective cohort study including patients submitted to CRT in a tertiary hospital in southern Brazil from 2008 to 2014. Survival was assessed through a database of the State Department of Health (RS. Predictors of echocardiographic response were evaluated using Poisson regression. Survival analysis was performed by Cox regression and Kaplan Meyer curves. A two-tailed p value less than 0.05 was considered statistically significant. Results: A total of 170 patients with an average follow-up of 1011 ± 632 days were included. The total mortality was 30%. The independent predictors of mortality were age (hazard ratio [HR] of 1.05, p = 0.027, previous acute myocardial infarction (AMI (HR of 2.17, p = 0.049 and chronic obstructive pulmonary disease (COPD (HR of 3.13, p = 0.015. The percentage of biventricular stimulation at 6 months was identified as protective factor of mortality ([HR] 0.97, p = 0.048. The independent predictors associated with the echocardiographic response were absence of mitral insufficiency, presence of left bundle branch block and percentage of biventricular stimulation. Conclusion: Mortality in patients submitted to CRT in a tertiary hospital was independently associated with age, presence of COPD and previous AMI. The percentage of biventricular pacing evaluated 6 months after resynchronizer implantation was independently associated with improved survival and echocardiographic response.

  14. Temperature mapping of sunspots and pores from speckle reconstructed three colour photometry

    NARCIS (Netherlands)

    Sütterlin, P.; Wiehr, E.

    1998-01-01

    The two-dimensional temperature distribution in a highly structured sunspot and in two small umbrae is determined from a three-colour photometry in narrow spectral continua. Disturbing influences from the earth’s atmosphere are removed by speckle masking techniques, yielding a spatial resolution

  15. Rat retinal vasomotion assessed by laser speckle imaging

    DEFF Research Database (Denmark)

    Neganova, Anastasiia Y; Postnov, Dmitry D; Sosnovtseva, Olga

    2017-01-01

    Vasomotion is spontaneous or induced rhythmic changes in vascular tone or vessel diameter that lead to rhythmic changes in flow. While the vascular research community debates the physiological and pathophysiological consequence of vasomotion, there is a great need for experimental techniques...... that can address the role and dynamical properties of vasomotion in vivo. We apply laser speckle imaging to study spontaneous and drug induced vasomotion in retinal network of anesthetized rats. The results reveal a wide variety of dynamical patterns. Wavelet-based analysis shows that (i) spontaneous...

  16. Noncontact speckle-based optical sensor for detection of glucose concentration using magneto-optic effect

    Science.gov (United States)

    Ozana, Nisan; Beiderman, Yevgeny; Anand, Arun; Javidi, Baharam; Polani, Sagi; Schwarz, Ariel; Shemer, Amir; Garcia, Javier; Zalevsky, Zeev

    2016-06-01

    We experimentally verify a speckle-based technique for noncontact measurement of glucose concentration in the bloodstream. The final device is intended to be a single wristwatch-style device containing a laser, a camera, and an alternating current (ac) electromagnet generated by a solenoid. The experiments presented are performed in vitro as proof of the concept. When a glucose substance is inserted into a solenoid generating an ac magnetic field, it exhibits Faraday rotation, which affects the temporal changes of the secondary speckle pattern distributions. The temporal frequency resulting from the ac magnetic field was found to have a lock-in amplification role, which increased the observability of the relatively small magneto-optic effect. Experimental results to support the proposed concept are presented.

  17. Visual Detection of Speckles in the Fish Xenotoca variata by the Predatory Snake Thamnophis melanogaster in Water of Different Turbidity.

    Science.gov (United States)

    Manjarrez, Javier; Rivas-González, Eric; Venegas-Barrera, Crystian S; Moyaho, Alejandro

    2015-01-01

    Semi-aquatic snakes integrate visual and chemical stimuli, and prey detection and capture success are therefore linked to the display of visual predatory behavior. The snake Thamnophis melanogaster responds preferentially to individuals of the fish Xenotoca variata with a greater number of bright, colorful spots (lateral speckles) compared with those with a smaller number; however, water turbidity can reduce underwater visibility and effect the vulnerability of fish. In this study, we tested whether the presence of iridescent speckles on the flanks of male X. variata interacted with water turbidity to modify the predatory behavior displayed by the snake T. melanogaster. We predicted that in an experimental laboratory test, the snakes would increase the frequency of their predatory behavior to the extent that the water turbidity decreases. The snakes were tested at six different levels of water turbidity, in combination with three categories of male fish (with few, a median number of, or many speckles). The results showed that in a pool with high or zero turbidity, the number of speckles is not a determining factor in the deployment of the predatory behavior of the snake T. melanogaster toward X. variata. Our findings suggest that snakes can view the fish at intermediate percentages of turbidity, but the number of speckles in male X. variata is irrelevant as an interspecific visual signal in environments with insufficient luminosity. The successful capture of aquatic prey is influenced by integration between chemical and visual signals, according to environmental factors that may influence the recognition of individual traits.

  18. Echocardiographic chamber quantification in a healthy Dutch population.

    Science.gov (United States)

    van Grootel, R W J; Menting, M E; McGhie, J; Roos-Hesselink, J W; van den Bosch, A E

    2017-12-01

    For accurate interpretation of echocardiographic measurements normative data are required, which are provided by guidelines. For this article, the hypothesis was that these cannot be extrapolated to the Dutch population, since in Dutch clinical practice often higher values are found, which may not be pathological but physiological. Therefore this study aimed to 1) obtain and propose normative values for cardiac chamber quantification in a healthy Dutch population and 2) determine influences of baseline characteristics on these measurements. Prospectively recruited healthy subjects, aged 20-72 years (at least 28 subjects per age decade, equally distributed for gender) underwent physical examination and 2D and 3D echocardiography. Both ventricles and atria were assessed and volumes were calculated. 147 subjects were included (age 44 ± 14 years, 50% female). Overall, feasibility was good for both linear and volumetric measurements. Linear and volumetric parameters were consistently higher than current guidelines recommend, while functional parameters were in line with the guidelines. This was more so in the older population. 3D volumes were higher than 2D volumes. Gender dependency was seen in all body surface area (BSA) corrected volumes and with increasing age, ejection fractions decreased. This study provides 2D and 3D echocardiographic reference ranges for both ventricles and atria derived from a healthy Dutch population. BSA indexed volumes are gender-dependent, age did not influence ventricular volumes and a rise in blood pressure was independently associated with increased right ventricular volumes. The higher volumes found may be indicative for the Dutch population being the tallest in the world.

  19. A Speckle survey of Southern Hipparcos Visual Doubles and Geneva-Copenhagen Spectroscopic Binaries

    Science.gov (United States)

    Mendez, R. A.; Tokovinin, A.; Horch, E.

    2018-01-01

    We present a speckle survey of Hipparcos visual doubles and spectroscopic binary stars identified by the Geneva-Copenhagen spectroscopic survey with the SOAR 4m telescope + HRCam. These systems represent our best chance to take advantage of Gaia parallaxes for the purpose of stellar mass determinations. Many of these systems already have mass fractions (although generally no spectroscopic orbit - an astrometric orbit will determine individual masses), metallicity information, and Hipparcos distances. They will be used to improve our knowledge of the mass-luminosity relation, particularly for lower-metallicity stars. Our survey will create the first all-sky, volume-limited, speckle archive for the two primary samples, complementing a similar effort that has been recently been completed at the WIYN 3.5-m telescope in the Northern Hemisphere. This extension to the Southern Hemisphere will fill out the picture for a wider metallicity range.

  20. Estimation of vessel diameter and blood flow dynamics from laser speckle images

    DEFF Research Database (Denmark)

    Postnov, Dmitry D.; Tuchin, Valery V.; Sosnovtseva, Olga

    2016-01-01

    Laser speckle imaging is a rapidly developing method to study changes of blood velocity in the vascular networks. However, to assess blood flow and vascular responses it is crucial to measure vessel diameter in addition to blood velocity dynamics. We suggest an algorithm that allows for dynamical...

  1. Superpositions of higher-order bessel beams and nondiffracting speckle fields - (SAIP 2009)

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2009-07-01

    Full Text Available speckle fields. The paper reports on illuminating a ring slit aperture with light which has an azimuthal phase dependence, such that the field produced is a superposition of two higher-order Bessel beams. In the case that the phase dependence of the light...

  2. Systolic and Diastolic Left Ventricular Mechanics during and after Resistance Exercise.

    Science.gov (United States)

    Stöhr, Eric J; Stembridge, Mike; Shave, Rob; Samuel, T Jake; Stone, Keeron; Esformes, Joseph I

    2017-10-01

    To improve the current understanding of the impact of resistance exercise on the heart, by examining the acute responses of left ventricular (LV) strain, twist, and untwisting rate ("LV mechanics"). LV echocardiographic images were recorded in systole and diastole before, during and immediately after (7-12 s) double-leg press exercise at two intensities (30% and 60% of maximum strength, one-repetition maximum). Speckle tracking analysis generated LV strain, twist, and untwisting rate data. Additionally, beat-by-beat blood pressure was recorded and systemic vascular resistance (SVR) and LV wall stress were calculated. Responses in both exercise trials were statistically similar (P > 0.05). During effort, stroke volume decreased, whereas SVR and LV wall stress increased (P mechanics (P 0.05). Immediately after exercise, systolic LV mechanics returned to baseline levels (P mechanics, but increases diastolic mechanics after exercise, suggesting that resistance exercise has a differential impact on systolic and diastolic heart muscle function. The findings may explain why acute resistance exercise has been associated with reduced stroke volume but chronic exercise training may result in increased LV volumes.

  3. MYOCARDIAL DEFORMATION AND COMPLETE LEFT BUNDLE BRANCH BLOCK

    Directory of Open Access Journals (Sweden)

    E. N. Pavlyukova

    2015-12-01

    Full Text Available Tissue Doppler imaging is evolving as a useful echocardiographic tool for quantitative assessment of left ventricular systolic and diastolic function. Over the last 10 years, myocardial deformation imaging has become possible initially with tissue Doppler , and more recently with myocardial speckle-tracking using 2D echocardiography. Unlike simple tissue velocity measurements, deformation measurements are specific for the region of interest. Strain rate or strain measurements have been used as sensitive indicators for subclinical diseases, and it is the most widely used tool to assess mechanical dyssynchrony. Left bundle branch block is a frequent, etiologically heterogeneous, clinically hostile and diagnostically challenging entity. About 2% of patients underwent cardiac stress testing show stable or intermittent left bundle branch block. Presence of left bundle branch block is associated with a lower and slower diastolic coronary flow velocity especially during hyperemia. Stress echocardiography is the best option for the diagnosis of ischemic heart disease, albeit specificity and sensitivity reduce in patients with left bundle branch block in the territory of left anterior descending artery in presence of initial septum dyskinesia.

  4. Speckle-based at-wavelength metrology of X-ray mirrors with super accuracy.

    Science.gov (United States)

    Kashyap, Yogesh; Wang, Hongchang; Sawhney, Kawal

    2016-05-01

    X-ray active mirrors, such as bimorph and mechanically bendable mirrors, are increasingly being used on beamlines at modern synchrotron source facilities to generate either focused or "tophat" beams. As well as optical tests in the metrology lab, it is becoming increasingly important to optimise and characterise active optics under actual beamline operating conditions. Recently developed X-ray speckle-based at-wavelength metrology technique has shown great potential. The technique has been established and further developed at the Diamond Light Source and is increasingly being used to optimise active mirrors. Details of the X-ray speckle-based at-wavelength metrology technique and an example of its applicability in characterising and optimising a micro-focusing bimorph X-ray mirror are presented. Importantly, an unprecedented angular sensitivity in the range of two nanoradians for measuring the slope error of an optical surface has been demonstrated. Such a super precision metrology technique will be beneficial to the manufacturers of polished mirrors and also in optimization of beam shaping during experiments.

  5. Influence of the number of cones on speckle patterns in the Laser MegaJoule configuration

    International Nuclear Information System (INIS)

    Le Cain, A.; Riazuelo, G.; Sajer, J. M.

    2013-01-01

    This paper investigates statistical properties of hot spots when speckle patterns are generated by the superimposition of multiple laser beams in a 2 cone and a 3 cone Laser MegaJoule configuration in the zone where all the beams overlap. Three different cases of polarizations are investigated: P polarization, S polarization and the case of Double Polarization Smoothing (DPS). It is found that the sizes of the speckles depend on the choice of the polarization and that DPS seems to be the best option in both configurations. It is shown that the longitudinal radius of the hot spots in a 2 cone configuration is bigger than in a 3 cone configuration. (authors)

  6. Prognostic usefulness of repeated echocardiographic evaluation after acute myocardial infarction. TRACE Study Group. TRAndolapril Cardiac Evaluation

    DEFF Research Database (Denmark)

    Korup, E; Køber, L; Torp-Pedersen, C

    1999-01-01

    The prognostic value of repeated echocardiographic measurement of left ventricular function after acute myocardial infarction was evaluated. We found that repeated measurements of wall motion index in survivors of acute myocardial infarction, with no reinfarction, provide important prognostic...

  7. Left Ventricular Function after Arterial Switch Operation as Assessed by Two-Dimensional Speckle-Tracking Echocardiography in Patients with Simple Transposition of the Great Arteries.

    Science.gov (United States)

    Malakan Rad, Elaheh; Ghandi, Yazdan; Kocharian, Armen; Mirzaaghayan, Mohammadreza

    2016-07-06

    Background: The late postoperative course for children with transposition of the great arteries (TGA) with an intact ventricular septum (IVS) is very important because the coronary arteries may be at risk of damage during arterial switch operation (ASO). We sought to investigate left ventricular function in patients with TGA/IVS by echocardiography. Methods: From March 2011 to December 2012, totally 20 infants (12 males and 8 females) with TGA/IVS were evaluated via 2-dimensional speckle-tracking echocardiography (2D STE) more than 6 months after they underwent ASO. A control group of age-matched infants and children was also studied. Left ventricular longitudinal strain (S), strain rate (SR), time to peak systolic longitudinal strain (TPS), and time to peak systolic longitudinal strain rate (TPSR) were measured and compared between the 2 groups. Results: Mean ± SD of age at the time of study in the patients with TGA/IVS was 15 ± 5 months, and also age at the time of ASO was 12 ± 3 days. Weight was 3.13 ± 0.07 kg at birth and 8.83 ± 1.57 kg at the time of ASO. Global strain (S), Time to peak strain rate (TPSR), and Time to peak strain (TPS) were not significantly different between the 2 groups, whereas global strain rate (SR) was significantly different (p value < 0.001). In the 3-chamber view, the values of S in the lateral, septal, inferior, and anteroseptal walls were significantly different between the 2 groups (p value < 0.001), and SR in the posterior wall was significantly different between the 2 groups (p value < 0.001). There were no positive correlations between S and SR in terms of the variables of heart rate, total cardiopulmonary bypass time, and aortic cross-clamp time. There were no statistically significant differences between the 2 groups regarding S, SR, TPS, and TPSR in the anteroseptal and posterior walls in the 3-chamber view and in the lateral and septal walls in the 4-chamber view. Conclusion: We showed that between 6 and 18 months after

  8. Digital speckle correlation for nondestructive testing of corrosion

    Science.gov (United States)

    Paiva, Raul D., Jr.; Soga, Diogo; Muramatsu, Mikiya; Hogert, Elsa N.; Landau, Monica R.; Ruiz Gale, Maria F.; Gaggioli, Nestor G.

    1999-07-01

    This paper describes the use of optical correlation speckle patterns to detect and analyze the metallic corrosion phenomena, and shows the experimental set-up used. We present some new results in the characterization of the corrosion process using a model based in electroerosion phenomena. We also provide valuable information about surface microrelief changes, which is also useful in numerous engineering applications. The results obtained are good enough for showing that our technique is very useful for giving new possibilities to the analysis of the corrosion and oxidation process, particularly in real time.

  9. Speckle techniques for determining stresses in moving objects

    Science.gov (United States)

    Murphree, E. A.; Wilson, T. F.; Ranson, W. F.; Swinson, W. F.

    1978-01-01

    Laser speckle interferometry is a relatively new experimental technique which shows promise of alleviating many difficult problems in experimental mechanics. The method utilizes simple high-resolution photographs of the surface which is illuminated by coherent light. The result is a real-time or permanently stored whole-field record of interference fringes which yields a map of displacements in the object. In this thesis, the time-average theory using the Fourier transform is developed to present the application of this technique to measurement of in-plane displacement induced by the vibration of an object.

  10. Egg Speckling Patterns Do Not Advertise Offspring Quality or Influence Male Provisioning in Great Tits

    Science.gov (United States)

    Stoddard, Mary Caswell; Fayet, Annette L.; Kilner, Rebecca M.; Hinde, Camilla A.

    2012-01-01

    Many passerine birds lay white eggs with reddish brown speckles produced by protoporphyrin pigment. However, the function of these spots is contested. Recently, the sexually selected eggshell coloration (SSEC) hypothesis proposed that eggshell color is a sexually selected signal through which a female advertises her quality (and hence the potential quality of her future young) to her male partner, thereby encouraging him to contribute more to breeding attempts. We performed a test of the SSEC hypothesis in a common passerine, the great tit Parus major. We used a double cross-fostering design to determine whether males change their provisioning behavior based on eggshell patterns they observe at the nest. We also tested the assumption that egg patterning reflects female and/or offspring quality. Because birds differ from humans in their color and pattern perception, we used digital photography and models of bird vision to quantify egg patterns objectively. Neither male provisioning nor chick growth was related to the pattern of eggs males observed during incubation. Although heavy females laid paler, less speckled eggs, these eggs did not produce chicks that grew faster. Therefore, we conclude that the SSEC hypothesis is an unlikely explanation for the evolution of egg speckling in great tits. PMID:22815730

  11. State of the Art of X-ray Speckle-Based Phase-Contrast and Dark-Field Imaging

    Directory of Open Access Journals (Sweden)

    Marie-Christine Zdora

    2018-04-01

    Full Text Available In the past few years, X-ray phase-contrast and dark-field imaging have evolved to be invaluable tools for non-destructive sample visualisation, delivering information inaccessible by conventional absorption imaging. X-ray phase-sensing techniques are furthermore increasingly used for at-wavelength metrology and optics characterisation. One of the latest additions to the group of differential phase-contrast methods is the X-ray speckle-based technique. It has drawn significant attention due to its simple and flexible experimental arrangement, cost-effectiveness and multimodal character, amongst others. Since its first demonstration at highly brilliant synchrotron sources, the method has seen rapid development, including the translation to polychromatic laboratory sources and extension to higher-energy X-rays. Recently, different advanced acquisition schemes have been proposed to tackle some of the main limitations of previous implementations. Current applications of the speckle-based method range from optics characterisation and wavefront measurement to biomedical imaging and materials science. This review provides an overview of the state of the art of the X-ray speckle-based technique. Its basic principles and different experimental implementations as well as the the latest advances and applications are illustrated. In the end, an outlook for anticipated future developments of this promising technique is given.

  12. Egg speckling patterns do not advertise offspring quality or influence male provisioning in great tits.

    Directory of Open Access Journals (Sweden)

    Mary Caswell Stoddard

    Full Text Available Many passerine birds lay white eggs with reddish brown speckles produced by protoporphyrin pigment. However, the function of these spots is contested. Recently, the sexually selected eggshell coloration (SSEC hypothesis proposed that eggshell color is a sexually selected signal through which a female advertises her quality (and hence the potential quality of her future young to her male partner, thereby encouraging him to contribute more to breeding attempts. We performed a test of the SSEC hypothesis in a common passerine, the great tit Parus major. We used a double cross-fostering design to determine whether males change their provisioning behavior based on eggshell patterns they observe at the nest. We also tested the assumption that egg patterning reflects female and/or offspring quality. Because birds differ from humans in their color and pattern perception, we used digital photography and models of bird vision to quantify egg patterns objectively. Neither male provisioning nor chick growth was related to the pattern of eggs males observed during incubation. Although heavy females laid paler, less speckled eggs, these eggs did not produce chicks that grew faster. Therefore, we conclude that the SSEC hypothesis is an unlikely explanation for the evolution of egg speckling in great tits.

  13. Echocardiographic parameters and survival in Chagas heart disease with severe systolic dysfunction.

    Science.gov (United States)

    Rassi, Daniela do Carmo; Vieira, Marcelo Luiz Campos; Arruda, Ana Lúcia Martins; Hotta, Viviane Tiemi; Furtado, Rogério Gomes; Rassi, Danilo Teixeira; Rassi, Salvador

    2014-03-01

    Echocardiography provides important information on the cardiac evaluation of patients with heart failure. The identification of echocardiographic parameters in severe Chagas heart disease would help implement treatment and assess prognosis. To correlate echocardiographic parameters with the endpoint cardiovascular mortality in patients with ejection fraction Celular em Cardiopatias) - Chagas heart disease arm. The following parameters were collected: left ventricular systolic and diastolic diameters and volumes; ejection fraction; left atrial diameter; left atrial volume; indexed left atrial volume; systolic pulmonary artery pressure; integral of the aortic flow velocity; myocardial performance index; rate of increase of left ventricular pressure; isovolumic relaxation time; E, A, Em, Am and Sm wave velocities; E wave deceleration time; E/A and E/Em ratios; and mitral regurgitation. In the mean 24.18-month follow-up, 27 patients died. The mean ejection fraction was 26.6 ± 5.34%. In the multivariate analysis, the parameters ejection fraction (HR = 1.114; p = 0.3704), indexed left atrial volume (HR = 1.033; p 70.71 mL/m2 were associated with a significant increase in mortality (log rank p < 0.0001). The indexed left atrial volume was the only independent predictor of mortality in this population of Chagasic patients with severe systolic dysfunction.

  14. Real time processor for array speckle interferometry

    Science.gov (United States)

    Chin, Gordon; Florez, Jose; Borelli, Renan; Fong, Wai; Miko, Joseph; Trujillo, Carlos

    1989-02-01

    The authors are constructing a real-time processor to acquire image frames, perform array flat-fielding, execute a 64 x 64 element two-dimensional complex FFT (fast Fourier transform) and average the power spectrum, all within the 25 ms coherence time for speckles at near-IR (infrared) wavelength. The processor will be a compact unit controlled by a PC with real-time display and data storage capability. This will provide the ability to optimize observations and obtain results on the telescope rather than waiting several weeks before the data can be analyzed and viewed with offline methods. The image acquisition and processing, design criteria, and processor architecture are described.

  15. Digital Image Speckle Correlation for the Quantification of the Cosmetic Treatment with Botulinum Toxin Type A (BTX-A)

    Science.gov (United States)

    Bhatnagar, Divya; Conkling, Nicole; Rafailovich, Miriam; Dagum, Alexander

    2012-02-01

    The skin on the face is directly attached to the underlying muscles. Here, we successfully introduce a non-invasive, non-contact technique, Digital Image Speckle Correlation (DISC), to measure the precise magnitude and duration of facial muscle paralysis inflicted by BTX-A. Subjective evaluation by clinicians and patients fail to objectively quantify the direct effect and duration of BTX-A on the facial musculature. By using DISC, we can (a) Directly measure deformation field of the facial skin and determine the locus of facial muscular tension(b)Quantify and monitor muscular paralysis and subsequent re-innervation following injection; (c) Continuously correlate the appearance of wrinkles and muscular tension. Two sequential photographs of slight facial motion (frowning, raising eyebrows) are taken. DISC processes the images to produce a vector map of muscular displacement from which spatially resolved information is obtained regarding facial tension. DISC can track the ability of different muscle groups to contract and can be used to predict the site of injection, quantify muscle paralysis and the rate of recovery following BOTOX injection.

  16. Comparison of echocardiographic findings in patients with nonfunctioning adrenal incidentalomas

    Directory of Open Access Journals (Sweden)

    Narin Nasıroglu Imga

    2017-06-01

    Full Text Available Adrenal incidentalomas (AIs are usually discovered incidentally after imaging unrelated to adrenal glands. We aimed to evaluate standard risk factors for systemic atherosclerosis and echocardiographic changes in patients with nonfunctioning AIs and compare them with normal subjects. We evaluated 70 patients diagnosed with AIs and 51 healthy controls. Mean levels were determined for HbA1c, LDL, uric acid, fasting plasma insulin, HOMA, and neutrophil-to-lymphocyte ratio (NLR, and these values were found to be significantly higher in the patients than the controls. The mean left atrial diameter, interventricular septum thickness, posterior wall thickness, left ventricular mass, E-wave deceleration time, isovolumetric relaxation time, and the median ratio of the early transmittal flow velocity to the early diastolic tissue velocity (E/Em were higher in patients with AIs compared to controls. The mitral annular early diastolic velocity was lower in patients with AIs. The mean aortic diastolic diameter, stiffness index (SI, and aortic strain were higher, and aortic distensibility was lower in the patients. The mean right ventricular diameter, right atrial major-axis diameter, and right atrial minor-axis diameter were statistically higher in the patient group than the controls. A negative correlation was found between the NLR and aortic strain and aortic distensibility, while a positive correction was found between the NLR and SI. We found altered left ventricular (LV and right ventricular (RV echocardiographic findings in patients with AIs without known cardiovascular disease. Aortic stiffness was also increased. These changes may be related to an increase in cardiovascular risk factors in AI patients.

  17. Right heart mechanics in untreated normotensive patients with prediabetes and type 2 diabetes mellitus: a two- and three-dimensional echocardiographic study.

    Science.gov (United States)

    Tadic, Marijana; Celic, Vera; Cuspidi, Cesare; Ilic, Sanja; Pencic, Biljana; Radojkovic, Jana; Ivanovic, Branislava; Stanisavljevic, Dejana; Kocabay, Gonenc; Marjanovic, Tamara

    2015-03-01

    The aim of this study was to determine right ventricular (RV) and right atrial (RA) deformation assessed by two-dimensional echocardiographic and three-dimensional echocardiographic (3DE) imaging in patients with prediabetes and type 2 diabetes mellitus. This cross-sectional study included 47 untreated normotensive subjects with prediabetes, 57 recently diagnosed normotensive patients with diabetes, and 54 healthy controls of similar sex and age distributions. All subjects underwent laboratory analyses and complete two-dimensional echocardiographic and 3DE examinations. Three-dimensional echocardiographic RV end-diastolic volume index gradually decreased from controls across patients with diabetes to those with diabetes (69 ± 10 vs 63 ± 8 vs 58 ± 8 mL/m(2), P < .001), whereas 3DE RV end-systolic volume index was higher in controls compared with patients with diabetes and those with diabetes (25 ± 4 vs 23 ± 4 vs 22 ± 4 mL/m(2), P < .001). However, there was no difference in 3DE RV ejection fraction among the three groups (63 ± 4% vs 62 ± 4% vs 61 ± 5%, P = .063). RV and RA global strain and systolic and early diastolic strain rates were decreased in patients with prediabetes and in those with diabetes compared with controls, whereas RV and RA late diastolic strain rates were increased in these patients. Multivariate regression analysis showed that RV global strain was associated with glycated hemoglobin, independent of left ventricular parameters. RV and RA myocardial deformation and function obtained by 3DE and two-dimensional echocardiographic strain, even in normal ranges, were decreased in patients with prediabetes and in those with diabetes compared with controls. The long-term parameter of glucose control was correlated with the right heart mechanics. Copyright © 2015 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  18. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. III. MEASURES BELOW THE DIFFRACTION LIMIT OF THE WIYN TELESCOPE

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Van Altena, William F.; Howell, Steve B.; Sherry, William H.; Ciardi, David R.

    2011-01-01

    In this paper, we study the ability of CCD- and electron-multiplying-CCD-based speckle imaging to obtain reliable astrometry and photometry of binary stars below the diffraction limit of the WIYN 3.5 m Telescope. We present a total of 120 measures of binary stars, 75 of which are below the diffraction limit. The measures are divided into two groups that have different measurement accuracy and precision. The first group is composed of standard speckle observations, that is, a sequence of speckle images taken in a single filter, while the second group consists of paired observations where the two observations are taken on the same observing run and in different filters. The more recent paired observations were taken simultaneously with the Differential Speckle Survey Instrument, which is a two-channel speckle imaging system. In comparing our results to the ephemeris positions of binaries with known orbits, we find that paired observations provide the opportunity to identify cases of systematic error in separation below the diffraction limit and after removing these from consideration, we obtain a linear measurement uncertainty of 3-4 mas. However, if observations are unpaired or if two observations taken in the same filter are paired, it becomes harder to identify cases of systematic error, presumably because the largest source of this error is residual atmospheric dispersion, which is color dependent. When observations are unpaired, we find that it is unwise to report separations below approximately 20 mas, as these are most susceptible to this effect. Using the final results obtained, we are able to update two older orbits in the literature and present preliminary orbits for three systems that were discovered by Hipparcos.

  19. Accelerated speckle imaging with the ATST visible broadband imager

    Science.gov (United States)

    Wöger, Friedrich; Ferayorni, Andrew

    2012-09-01

    The Advanced Technology Solar Telescope (ATST), a 4 meter class telescope for observations of the solar atmosphere currently in construction phase, will generate data at rates of the order of 10 TB/day with its state of the art instrumentation. The high-priority ATST Visible Broadband Imager (VBI) instrument alone will create two data streams with a bandwidth of 960 MB/s each. Because of the related data handling issues, these data will be post-processed with speckle interferometry algorithms in near-real time at the telescope using the cost-effective Graphics Processing Unit (GPU) technology that is supported by the ATST Data Handling System. In this contribution, we lay out the VBI-specific approach to its image processing pipeline, put this into the context of the underlying ATST Data Handling System infrastructure, and finally describe the details of how the algorithms were redesigned to exploit data parallelism in the speckle image reconstruction algorithms. An algorithm re-design is often required to efficiently speed up an application using GPU technology; we have chosen NVIDIA's CUDA language as basis for our implementation. We present our preliminary results of the algorithm performance using our test facilities, and base a conservative estimate on the requirements of a full system that could achieve near real-time performance at ATST on these results.

  20. Spectral OCT with speckle contrast reduction for evaluation of the healing process after PRK and transepithelial PRK.

    Science.gov (United States)

    Kaluzny, Bartlomiej J; Szkulmowski, Maciej; Bukowska, Danuta M; Wojtkowski, Maciej

    2014-04-01

    We evaluate Spectral OCT (SOCT) with a speckle contrast reduction technique using resonant scanner for assessment of corneal surface changes after excimer laser photorefractive keratectomy (PRK) and we compare healing process between conventional PRK and transepithelial PRK. The measurements were performed before and after the surgery. Obtained results show that SOCT with a resonant scanner speckle contrast reduction is capable of providing information regarding the healing process after PRK. The main difference between the healing processes of PRK and TransPRK, assessed by SOCT, was the time to cover the stroma with epithelium, which was shorter in the TransPRK group.