WorldWideScience

Sample records for specimen holders

  1. Structural analysis of 177-FA redesigned surveillance specimen holder tube

    Pryor, C.W.; Thoren, D.E.; Vames, G.J.; Harris, R.J.

    1976-08-01

    Because of in-service operational problems, the surveillance specimen holder tubes described in B and W topical report BAW-10051 have been redesigned. This report describes the new design and structural analysis for normal operation and upset loading conditions. The results of the analysis demonstrate the adequacy of the new surveillance specimen holder tubes for their design life of 40 years

  2. 16 CFR Figure 3 to Part 1610 - Specimen Holder Supported in Specimen Rack

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Specimen Holder Supported in Specimen Rack 3 Figure 3 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Holder Supported in Specimen Rack ER25MR08.002 ...

  3. A cylindrical specimen holder for electron cryo-tomography

    Palmer, Colin M.; Löwe, Jan

    2014-01-01

    The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the “missing wedge” problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the problem, since they allow imaging from a full range of viewing angles around the tilt axis. Such specimens have been used before for tomography of radiation-insensitive samples at room temperature, but never for frozen-hydrated specimens. Here, we demonstrate the use of thin-walled carbon tubes as specimen holders, allowing the preparation of cylindrical frozen-hydrated samples of ribosomes, liposomes and whole bacterial cells. Images acquired from these cylinders have equal quality at all viewing angles, and the accessible tilt range is restricted only by the physical limits of the microscope. Tomographic reconstructions of these specimens demonstrate that the effects of the missing wedge are substantially reduced, and could be completely eliminated if a full tilt range was used. The overall quality of these tomograms is still lower than that obtained by existing methods, but improvements are likely in future. - Highlights: • The missing wedge is a serious problem for electron cryo-tomography. • Cylindrical specimens allow the missing wedge to be eliminated. • Carbon nanopipettes can be used as cylindrical holders for tomography of frozen-hydrated specimens. • Cryo-tomography of cylindrical biological samples demonstrates a reduction of deleterious effects associated with the missing wedge

  4. Specimen holder for an electron microscope and device and method for mounting a specimen in an electron microscope

    Zandbergen, H.W.; Latenstein van Voorst, A.; Westra, C.; Hoveling, G.H.

    1996-01-01

    A specimen holder for an electron microscope, comprising a bar-shaped body provided adjacent one end with means for receiving a specimen, with means being present for screening the specimen from the environment at least temporarily in airtight and moisture-proof manner in a first position, which

  5. An X-ray diffractometer specimen holder for use with reactive and toxic materials

    Huyton, A.; Munden, A.B.

    1979-04-01

    An X-ray diffractometer specimen holder has been designed for analysis of reactive sodium compounds which will satisfactorily seal the sample from the atmosphere. The holder can be readily filled in a glove-box and is easily transported for mounting on a vertical Philips PW 1051 X-ray diffractometer. It is considered that this holder could also be applied to a wide range of other reactive and toxic materials, e.g. plutonium or its compounds. (author)

  6. A simple cryo-holder facilitates specimen observation under a conventional scanning electron microscope.

    Tang, Chih-Yuan; Huang, Rong-Nan; Kuo-Huang, Ling-Long; Kuo, Tai-Chih; Yang, Ya-Yun; Lin, Ching-Yeh; Jane, Wann-Neng; Chen, Shiang-Jiuun

    2012-02-01

    A pre-cryogenic holder (cryo-holder) facilitating cryo-specimen observation under a conventional scanning electron microscope (SEM) is described. This cryo-holder includes a specimen-holding unit (the stub) and a cryogenic energy-storing unit (a composite of three cylinders assembled with a screw). After cooling, the cryo-holder can continue supplying cryogenic energy to extend the observation time for the specimen in a conventional SEM. Moreover, the cryogenic energy-storing unit could retain appropriate liquid nitrogen that can evaporate to prevent frost deposition on the surface of the specimen. This device is proved feasible for various tissues and cells, and can be applied to the fields of both biology and material science. We have employed this novel cryo-holder for observation of yeast cells, trichome, and epidermal cells in the leaf of Arabidopsis thaliana, compound eyes of insects, red blood cells, filiform papillae on the surface of rat tongue, agar medium, water molecules, penicillium, etc. All results suggested that the newly designed cryo-holder is applicable for cryo-specimen observation under a conventional SEM without cooling system. Most importantly, the design of this cryo-holder is simple and easy to operate and could adapt a conventional SEM to a plain type cryo-SEM affordable for most laboratories. Copyright © 2011 Wiley Periodicals, Inc.

  7. Development of a versatile TEM specimen holder for the characterization of photocatalytic materials

    Cavalca, Filippo; Langhammer, C.; Hansen, Thomas Willum

    2011-01-01

    conventional TEM analysis on photocatalysts with several in situ TEM techniques including environmental TEM (ETEM), in situ photo activation and localized surface plasmon resonance (LSPR) spectroscopy [3-4]. These experiments are facilitated by the construction of a specimen holder capable of illuminating....../on nanomaterials and thin films. We present results from combined ETEM-LSPR studies of thermally-induced catalytic phenomena and on metal nanoparticle sintering, an important process in catalysis, which we study in situ in both real and model systems by means of indirect nanoplasmonic sensing and ETEM....

  8. Specimen loading list for the varying temperature experiment

    Qualls, A.L.; Sitterson, R.G.

    1998-01-01

    The varying temperature experiment HFIR-RB-13J has been assembled and inserted in the reactor. Approximately 5300 specimens were cleaned, inspected, matched, and loaded into four specimen holders. A listing of each specimen loaded into the steady temperature holder, its position in the capsule, and the identification of the corresponding specimen loaded into the varying temperature holder is presented in this report

  9. Preset pivotal tool holder

    Asmanes, Charles

    1979-01-01

    A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.

  10. ADJUSTABLE CHIP HOLDER

    2009-01-01

    An adjustable microchip holder for holding a microchip is provided having a plurality of displaceable interconnection pads for connecting the connection holes of a microchip with one or more external devices or equipment. The adjustable microchip holder can fit different sizes of microchips...

  11. Automatic grinding apparatus to control uniform specimen thicknesses

    Bryner, Joseph S.

    1982-01-01

    This invention is directed to a new and improved grinding apparatus comprising (1) a movable grinding surface, (2) a specimen holder, (3) a displacing device for moving the holder and/or grinding surface toward one another, and (4) at least three devices for limiting displacement of the holder to the grinding surface.

  12. Improvements in appliance holders

    Chapman, J.E.

    1977-01-01

    Reference is made to appliance holders for locating tools, instruments, etc. in operative relationship to workpieces and accessible through passageways of restricted transverse dimensions. The appliance holder described comprises an elongated external frame provided with transversely, outwardly expanding frictional gripping means in two longitudinally spaced sets and with a ring of spur teeth. An inner elongated frame is held within the external frame in two longitudinally spaced rotary bearings and carries a spur wheel which engages the ring of the spur teeth. A motor is arranged to rotate the spur wheel and hence the inner frame in relation to the external frame. A carriage is carried by the inner frame, longitudinally movable by a motor in relation thereto, and a further carriage is mounted on this first carriage. This second cariage is transversely movable in relation to the inner frame and is provided with a face plate for attachment of tools, instruments, etc. A motor is mounted on the first carriage for moving the second carriage. (U.K.)

  13. Controlled Environment Specimen Transfer

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Hansen, Thomas Willum

    2014-01-01

    an environmental transmission electron microscope to an in situ X-ray diffractometer through a dedicated transmission electron microscope specimen transfer holder, capable of sealing the specimen in a gaseous environment at elevated temperatures. Two catalyst material systems have been investigated; Cu/ZnO/Al2O3...... transferred in a reactive environment to the environmental transmission electron microscope where further analysis on the local scale were conducted. The Co/Al2O3 catalyst was reduced in the environmental microscope and successfully kept reduced outside the microscope in a reactive environment. The in situ......Specimen transfer under controlled environment conditions, such as temperature, pressure, and gas composition, is necessary to conduct successive complementary in situ characterization of materials sensitive to ambient conditions. The in situ transfer concept is introduced by linking...

  14. Freeze Protection in Gas Holders

    Hjorth, Poul G.; Duursma, Gail

    In cold weather, the water seals of gasholders need protection from freez- ing to avoid compromising the seal. These holders have a large reservoir of “tank water” at the base which is below ground. At present freeze- protection is achieved by external heating of the seal water which...

  15. National Recordal System IK holder catalogue process

    Pretorius, R

    2012-10-01

    Full Text Available good, based on IK.? Subsequently, the South African Department of Science and Technology (DST) created a National Indigenous Knowledge Systems Office (NIKSO) that is taking the lead on interfacing IKS with other recognised knowledge holders... is to illustrate the South African National Recordal Systems (NRS) process whereby Indigenous Knowledge (IK) holder?s information is captured in a registry, as specified in South Africa?s Indigenous Knowledge Systems (IKS) Policy, through an IK cataloguing...

  16. Diffeomorphisms Holder conjugate to Anosov diffeomorphisms

    Gogolev, Andrey

    2008-01-01

    We show by means of a counterexample that a $C^{1+Lip}$ diffeomorphism Holder conjugate to an Anosov diffeomorphism is not necessarily Anosov. The counterexample can bear higher smoothness up to $C^3$. Also we include a result from the 2006 Ph.D. thesis of T. Fisher: a $C^{1+Lip}$ diffeomorphism Holder conjugate to an Anosov diffeomorphism is Anosov itself provided that Holder exponents of the conjugacy and its inverse are sufficiently large.

  17. Improved sample holders for the PMMA dosimeters

    Kobayashi, Toshikazu; Sone, Koji; Iso, Katsuaki

    1994-01-01

    PMMA dosimeters are widely used for high dose dosimetry. Dose is determined by measuring the change in optical density of the irradiated PMMA dosimeter element. Measurement precision depends on the mounting method of a dosimeter element in the sample room of a spectrophotometer. We tried to prepare three types of holders, (holders A, B and C in Figs. 1-3), according to the shape of PMMA dosimeter elements. We measured optical density of the irradiated PMMA dosimeter elements by using the three types of holders. It is revealed that the holder of the type A gives more precise results for the Red 4034 or Gammachrome YR dosimeter than that of the type B. The measurements with a spectrophotometer using the type C holder gives better results for the Red acrylic dosimeter than the case of the measurements by the exclusive reader. (author)

  18. Report on the Installation and Preparedness of a Protochips Fusion in-situ Heating Holder for TEM

    Edmondson, Philip D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    This brief report documents the procurement and installation of a Protochips Fusion (formerly Aduro) high-temperature, high stability transmission electron microscopy (TEM) specimen holder that allows for the high spatial resolution characterization of material specimens at high temperature in situ of an electron microscope. This specimen holder was specifically procured for use with The FEI Talos F200X Scanning/Transmission Electron Microscope (STEM) in Oak Ridge National Laboratory’s (ORNL’s) Low Activation Materials Development and Analysis (LAMDA) Laboratory. The Protochips Fusion holder will enable high-resolution structural and chemical analysis of irradiated materials at high temperature, becoming a unique capability worldwide, and would encourage high-quality in situ experiments to be conducted on irradiated materials.

  19. 19 CFR 10.7 - Substantial containers or holders.

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Substantial containers or holders. 10.7 Section 10... Exported and Returned § 10.7 Substantial containers or holders. (a) Substantial containers or holders... domestic products exported and returned. When such containers or holders are imported not containing or...

  20. A triple axes multiple target holder assembly

    Tribedi, L.C.; Narvekar, S.D.; Pillay, R.G.; Tandon, P.N.

    1993-01-01

    We have designed and fabricated a rotatable target holder assembly capable of accommodating 27 targets. The target foils are mounted along two concentric circles on a ss wheel. On the outer circle 18 targets can be mounted each 20deg apart, and on the inner circle the remaining targets are positioned each 40deg apart. The self supporting or carbon backed targets are mounted on thin frames and are placed concentrically at the targets are mounted on thin frames and are placed concentrically at the target position on the wheel. Three degrees of freedom are provided to the target holder assembly. (author). 1 fig

  1. The effectiveness of an endotracheal tube holder

    Byung Gun Lim

    2016-01-01

    Full Text Available The security of the endotracheal tube (ETT is important in the anesthesia and intensive care settings. Recently, an ETT holder instead of an adhesive tape is frequently used to provide the fixation of the ETT. There are some studies that focused on the effectiveness of the ETT holder in preventing displacement of ETT compared to an adhesive tape (1, 2. I have experienced the use of an ETT holder (E-holder, KS medical, Bucheon, Korea in many different anesthesia settings and recognized its usefulness and convenience other than ETT security in the following specific settings.  Firstly, the ETT holder is definitely effective for patients undergoing procedures that frequently require the adjustment of ETT (or double lumen tube location including thoracic surgery. The location of double lumen tube needed for lung separation can be modified for effective ventilation during anesthetic induction or surgery, and after position changes. The tube can be easily relocated to the proper place for lung separation and effective ventilation by unlocking/relocking the button of the ETT holder under flexible bronchoscopic guidance (Fig. 1A, which can facilitate the operative procedure to be performed easily and quickly. Secondly, the ETT holder can be useful in procedures requiring the prone position (3. Especially, it is useful in all circumstances requiring the adjustment of ETT in the prone position. For instance, it is definitely useful for patients with Duchene muscular dystrophy undergoing scoliosis surgery under prone position. Adolescent patients with Duchene muscular dystrophy frequently have tracheobronchial malacia. If so, the airway pressure can be elevated due to the narrowing of the lesion of malacia when changed to the prone position (4. To overcome this problem, a reinforced ETT should be relocated so that it passes the narrowed tracheal lesion under flexible bronchoscopic guidance (Fig. 1B. However, the approach for this management is somewhat

  2. Acceptance Testing of Thermoluminescent Dosimeter Holders.

    Romanyukha, Alexander; Grypp, Matthew D; Sharp, Thad J; DiRito, John N; Nelson, Martin E; Mavrogianis, Stanley T; Torres, Jeancarlo; Benevides, Luis A

    2018-05-01

    The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS). The dosimeter consists of four LiF:Mg,Cu,P elements, mounted in Teflon® on an aluminum card and placed in a plastic holder. The holder contains a unique filter for each chip made of copper, acrylonitrile butadiene styrene (ABS), Mylar®, and tin. For accredited dosimetry labs, the ISO/IEC 17025:2005(E) requires an acceptance procedure for all new equipment. The Naval Dosimetry Center (NDC) has developed and tested a new non-destructive procedure, which enables the verification and the evaluation of embedded filters in the holders. Testing is based on attenuation measurements of low-energy radiation transmitted through each filter in a representative sample group of holders to verify that the correct filter type and thickness are present. The measured response ratios are then compared with the expected response ratios. In addition, each element's measured response is compared to the mean response of the group. The test was designed and tested to identify significant nonconformities, such as missing copper or tin filters, double copper or double tin filters, or other nonconformities that may impact TLD response ratios. During the implementation of the developed procedure, testing revealed a holder with a double copper filter. To complete the evaluation, the impact of the nonconformities on proficiency testing was examined. The evaluation revealed failures in proficiency testing categories III and IV when these dosimeters were irradiated to high-energy betas.

  3. Zaria Universal Oxygenator Holder phase I

    Sunday Adoga Edaigbini

    2014-01-01

    Full Text Available Introduction: The conduct of cardiopulmonary bypass surgery requires the use of equipment and devices like the oxygenator. The oxygenator comes in different makes and each manufacturer customizes the carrier or ′holder′ of this device specific to their design. Aim: This paper presents an innovation designed to overcome the need to purchase a different holder for every oxygenator thereby cutting the cost. Materials and Methods: A sheet of iron measuring 1.9 cm (width × 0.1 cm (thickness was used to design the holder circular main frame. Another sheet measuring 2 cm (width × 0.6 cm (thickness × 24 cm (length was used to construct a V-shaped handle with the arms of the V attached to the main frame 7 cm apart. At the narrow base of the handle is a latch requiring two 13-gauge screws to attach the holder to the heart-lung machine. Within the circumference of the main frame are four T-shaped side arms which grip the oxygenator; located at 2, 5, 7 and 11 O′clock positions. The stem of the T consist of a 0.6 cm (thickness × 13 cm (length rod drilled through the main frame. The cross of the T consists of variable lengths of the same sheet as the mainframe attached to the stem by a screw mechanism. At the base of the T, is attached a circular handle (4 cm in diameter made of 0.4 cm iron rod. Result: An oxygenator holder which weighs 1.75 kg with a total length of 54 cm (the diameter of the mainframe is 30 cm. Its advantages include (i affordability, (ii materials are locally accessible, (iii versatility (iv reproducibility. The disadvantages include, (i it requires some time to fit, (ii caution is required in fitting the oxygenator to avoid breakage, (iii a spanner is required to lock the latch. Conclusion: The concept of a universal holder is pertinent, especially in resource poor environments to avoid purchasing a new holder whenever the usual oxygenator common to the centre is unavailable. This device is amenable to further modifications to

  4. Manipulator for rotating and translating a sample holder

    van de Water, Jeroen [Breugel, NL; van den Oetelaar, Johannes [Eindhoven, NL; Wagner, Raymond [Gorinchem, NL; Slingerland, Hendrik Nicolaas [Venlo, NL; Bruggers, Jan Willem [Eindhoven, NL; Ottevanger, Adriaan Huibert Dirk [Malden, NL; Schmid, Andreas [Berkeley, CA; Olson, Eric A [Champaign, IL; Petrov, Ivan G [Champaign, IL; Donchev, Todor I [Urbana, IL; Duden, Thomas [Kensington, CA

    2011-02-08

    A manipulator for use in e.g. a Transmission Electron Microscope (TEM) is described, said manipulator capable of rotating and translating a sample holder (4). The manipulator clasps the round sample holder between two members (3A, 3B), said members mounted on actuators (2A, 2B). Moving the actuators in the same direction results in a translation of the sample holder, while moving the actuators in opposite directions results in a rotation of the sample holder.

  5. Lexan Linear Shaped Charge Holder with Magnets and Backing Plate

    Maples, Matthew W.; Dutton, Maureen L.; Hacker, Scott C.; Dean, Richard J.; Kidd, Nicholas; Long, Chris; Hicks, Robert C.

    2013-01-01

    A method was developed for cutting a fabric structural member in an inflatable module, without damaging the internal structure of the module, using linear shaped charge. Lexan and magnets are used in a charge holder to precisely position the linear shaped charge over the desired cut area. Two types of charge holders have been designed, each with its own backing plate. One holder cuts fabric straps in the vertical configuration, and the other charge holder cuts fabric straps in the horizontal configuration.

  6. Harmonising and Matching IPR Holders at IP Australia

    T’Mir D. Julius; Gaétan de Rassenfosse

    2014-01-01

    This document describes the methodology developed by the Melbourne Institute to: (i) harmonise holders of intellectual property rights (IPRs) at IP Australia (applications for patent, designs, trademarks and plant breeder’s rights); (ii) match Australian IPRs holders to the Australian business register; (iii) identify the ultimate owners within Australia; and (iv) identify which holders are small and medium size enterprises.

  7. 38 CFR 36.4341 - Death or insolvency of holder.

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... applicable in the event of: (1) Insolvency of holder; (2) Initiation of any bankruptcy or reorganization, or...

  8. 21 CFR 882.4460 - Neurosurgical head holder (skull clamp).

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...

  9. Urine culture - catheterized specimen

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  10. Glove holder system for containment shell

    Picco, B.

    1993-01-01

    A glove holder for an isolated chamber used e.g. for handling toxic or radioactive materials and made with at least one access port in its wall, equipped with a ring to which the glove is attached, has a sleeve which connects the ring to the glove proper and protects the forarm. The sleeve is in at least two sections, a first corrugated section and a second, supple section which is able to fold inside the first section. ADVANTAGE - Reduced costs and quantity of waste produced by enabling glove proper only to be replaced. (author)

  11. Head-positioning scintillation camera and head holder therefor

    Kay, T.D.

    1976-01-01

    A holder for immobilizing the head of a patient undergoing a vertex brain scan by a Gamma Scintillation Camera is described. The holder has a uniquely designed shape capable of comfortably supporting the head. In addition, this holder can be both adjustably and removably utilized in combination with the scintillation camera so as to enable the brain scan operation to take place while the patient is in the seated position

  12. 3D printing scanning electron microscopy sample holders: A quick and cost effective alternative for custom holder fabrication.

    Gabriel N Meloni

    Full Text Available A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.

  13. 12 CFR 569.3 - Holders of proxies.

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Holders of proxies. 569.3 Section 569.3 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY PROXIES § 569.3 Holders of proxies. No proxy of a mutual savings association with a term greater than eleven months or solicited at...

  14. Transmission electron microscope sample holder with optical features

    Milas, Mirko [Port Jefferson, NY; Zhu, Yimei [Stony Brook, NY; Rameau, Jonathan David [Coram, NY

    2012-03-27

    A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.

  15. Tomographic Heating Holder for In Situ TEM

    Gontard, Lionel C.; Dunin-Borkowski, Rafal E.; Fernández, Asunción

    2014-01-01

    distributions and changes in active surface area are quantified from tilt series of images acquired after subjecting the specimens to increasing temperatures. The porosity of the alumina support and the sintering mechanisms of the catalysts are shown to depend on distance from the heating filament....

  16. Laparoscopic specimen retrieval bags.

    Smorgick, Noam

    2014-10-01

    Specimen retrieval bags have long been used in laparoscopic gynecologic surgery for contained removal of adnexal cysts and masses. More recently, the concerns regarding spread of malignant cells during mechanical morcellation of myoma have led to an additional use of specimen retrieval bags for contained "in-bag" morcellation. This review will discuss the indications for use retrieval bags in gynecologic endoscopy, and describe the different specimen bags available to date.

  17. Ergonomic design and evaluation of a diagnostic ultrasound transducer holder.

    Ghasemi, Mohamad Sadegh; Hosseinzadeh, Payam; Zamani, Farhad; Ahmadpoor, Hossein; Dehghan, Naser

    2017-12-01

    Work-related musculoskeletal disorders (WMSDs) are injuries and disorders that affect the body's movement and musculoskeletal system. Awkward postures represent one of the major ergonomic risk factors that cause WMSDs among sonographers while working with an ultrasound transducer. This study aimed to design and evaluate a new holder for the ultrasound transducer. In the first phase a new holder was designed for the transducer, considering design principles. Evaluation of the new holder was then carried out by electrogoniometry and a locally perceived discomfort (LPD) scale. The application of design principles to the new holder resulted in an improvement of wrist posture and comfort. Wrist angles in extension, flexion, radial deviation and ulnar deviation were lower with utilization of the new holder. The severity of discomfort based on the LPD method in the two modes of work with and without the new holder was reported with values of 1.3 and 1.8, respectively (p ergonomics design principles was effective in minimizing wrist deviation and increasing comfort while working with the new holder.

  18. Georeferencing Animal Specimen Datasets

    van Erp, M.G.J.; Hensel, R.; Ceolin, D.; van der Meij, M.

    2014-01-01

    For biodiversity research, the field of study that is concerned with the richness of species of our planet, it is of the utmost importance that the location of an animal specimen find is known with high precision. Due to specimens often having been collected over the course of many years, their

  19. Practical aspects of the use of the X(2) holder for HRTEM-quality TEM sample preparation by FIB.

    van Mierlo, Willem; Geiger, Dorin; Robins, Alan; Stumpf, Matthias; Ray, Mary Louise; Fischione, Paul; Kaiser, Ute

    2014-12-01

    The X(2) holder enables the effective production of thin, electron transparent samples for high-resolution transmission electron microscopy (HRTEM). Improvements to the X(2) holder for high-quality transmission electron microscopy (TEM) sample preparation are presented in this paper. We discuss the influence of backscattered electrons (BSE) from the sample holder in determining the lamella thickness in situ and demonstrate that a significant improvement in thickness determination can be achieved by comparatively simple means using the relative BSE intensity. We show (using Monte Carlo simulations) that by taking into account the finite collection angle of the electron backscatter detector, an approximately 20% underestimation of the lamella thickness in a silicon sample can be avoided. However, a correct thickness determination for light-element lamellas still remains a problem with the backscatter method; we introduce a more accurate method using the energy dispersive X-ray spectroscopy (EDX) signal for in situ thickness determination. Finally, we demonstrate how to produce a thin lamella with a nearly damage-free surface using the X(2) holder in combination with sub-kV polishing in the Fischione Instruments׳ NanoMill(®) TEM specimen preparation system. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Darfur and the flaws of Holder v HLP

    Christopher Thornton

    2011-03-01

    Full Text Available When US Chief Justice Roberts handed down the judgment in Holder v Humanitarian Law Project, he revealed the Supreme Court’s tragic under-estimation of the potential of engagement with non-state armed groups....

  1. 21 CFR 892.1920 - Radiographic head holder.

    2010-04-01

    ...) Identification. A radiographic head holder is a device intended to position the patient's head during a... device is also exempt from the current good manufacturing practice requirements of the quality system...

  2. Tem holder for sample transfer under reaction conditions

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Wagner, Jakob Birkedal

    Environmental transmission electron microscopy (ETEM) studies are usually performed using conventional sample holders in a dedicated ETEM [1] or in a traditional TEM by use of a dedicated high-pressure cell sample holder [2]. In both cases, the setup defines the conditions regarding gas, pressure......]. Furthermore, dedicated transfer holders have been used to transfer catalyst samples between reactor set-ups and TEM at room temperature in inert atmosphere [5]. To take the full advantage of complementary in situ techniques, transfer under reactions conditions is essential. This study introduces the in situ...... transfer concept by use of a dedicated TEM transfer holder capable of enclosing the sample in a gaseous environment at temperatures up to approx. 900C. By oxidation and reduction experiments of Cu nanoparticles it is shown possible to keep the reaction conditions during transfer outside the microscope...

  3. Lathe tool bit and holder for machining fiberglass materials

    Winn, L. E. (Inventor)

    1972-01-01

    A lathe tool and holder combination for machining resin impregnated fiberglass cloth laminates is described. The tool holder and tool bit combination is designed to accommodate a conventional carbide-tipped, round shank router bit as the cutting medium, and provides an infinite number of cutting angles in order to produce a true and smooth surface in the fiberglass material workpiece with every pass of the tool bit. The technique utilizes damaged router bits which ordinarily would be discarded.

  4. Preserve specimens for reproducibility

    Krell, F.-T.; Klimeš, Petr; Rocha, L. A.; Fikáček, M.; Miller, S. E.

    2016-01-01

    Roč. 539, č. 7628 (2016), s. 168 ISSN 0028-0836 Institutional support: RVO:60077344 Keywords : reproducibility * specimen * biodiversity Subject RIV: EH - Ecology, Behaviour Impact factor: 40.137, year: 2016 http://www.nature.com/nature/journal/v539/n7628/full/539168b.html

  5. Knife - Holders in Ancient Egyptian Tombs (Religious and Artistic Study

    dr.Rasha Omran

    2015-01-01

    Full Text Available Studying ancient Egyptian tombs have long been an important source of information regarding many aspects of Egyptian religion. Walls of New Kingdom tombs are often decorated with plenty of painted religious scenes. While they were primarily private structures containing images selected by the person who expected to be housed there for eternity, the funerary monuments also reflect religious beliefs. While numerous researches focused on many of the religious scenes depicted on the walls of ancient Egyptian tombs, no one focused on the knife - holders' scenes. Hence, the current study focused on knife - holders scenes depicted on the walls of both royal and private tombs dating back to the New Kingdom at Thebes. The current study was undertaken to shed light on the meaning and the function of knife in Ancient Egypt. To study the role of the knife-holders in Ancient Egypt. To spot light on the actions and behaviors and locations of the knife-holders in Ancient Egyptian civilization. To spot light on the representations of the knife-holders on the walls of the ancient Egyptians tombs in the Valley of the Kings and Valley of the Queens as well as the private tombs at western Thebes. To focus on the shapes and positions of the Knife-holders in Ancient Egypt. To explain the difference between Knife - Holders and Demons. To achieve the objectives of the study, the required data were collected from periodicals, references presenting Knife Holders scenes. Preserving the scenes of knife - holders on the walls of the royal tombs in the Valley of the Kings and Valley of the Queens dating back to the New Kingdom as well as the private tombs at western Thebes that contributed to the interpretation of all the data gathered from literature. The preliminary results indicated that the term (Knife-Holders is an expression which indicates to tomb-guardians, demons or minor divinities. These minor deities were subordinate to the major gods and goddesses. They

  6. Equipment for linking source stand and film holder carriage

    Fajt, P.; Zeman, M.

    1987-01-01

    A device is described for precision link-up of a source stand provided with a spring-loaded cam and a film holder carriage provided with an arm with catches. The catches are mechanically connected to a control device firmly connected to the bottom part of the film holder carriage arm. The cam whose extended part is slidably mounted in the cover guide is secured in position with springs fitted from both sides. The control device consists of an electromagnet with armature connected to the control device pull-rod. The pull-rod provides mechanical connection of the catches and the control device. Upon pressing the pushbutton, the catches automatically engage the film holder cariage arm so that the motorized source stand operates without connection to the carriage. This significantly facilitates the operation of the equipment and reduces physical effort of the technician. The most significant advantage is the possibility of immediate change in operation mode. (J.B.). 5 figs

  7. Broadband sample holder for microwave spectroscopy of superconducting qubits

    Averkin, A. S.; Karpov, A.; Glushkov, E.; Abramov, N.; Shulga, K.; Huebner, U.; Il'ichev, E.; Ustinov, A. V.

    2014-01-01

    We present a practical design and implementation of a broadband sample holder suitable for microwave experiments with superconducting integrated circuits at millikelvin temperatures. Proposed design can be easily integrated in standard dilution cryostats, has flat pass band response in a frequency range from 0 to 32 GHz, allowing the RF testing of the samples with substrate size up to 4 × 4 mm 2 . The parasitic higher modes interference in the holder structure is analyzed and prevented via design considerations. The developed setup can be used for characterization of superconducting parametric amplifiers, bolometers, and qubits. We tested the designed sample holder by characterizing of a superconducting flux qubit at 20 mK temperature

  8. Biaxial Creep Specimen Fabrication

    JL Bump; RF Luther

    2006-01-01

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments

  9. Biaxial Creep Specimen Fabrication

    JL Bump; RF Luther

    2006-02-09

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments.

  10. Implementation of a Light Source in a TEM Sample Holder for In-situ Studies of Photocatalytic Materials

    Cavalca, Filippo; Hansen, Thomas Willum; Wagner, Jakob Birkedal

    can be used inside an environmental TEM (ETEM) allowing specimens to be analyzed during exposure to a controlled gas atmosphere and illumination. The holder is presently being used to study a variety of photoreactive materials and structures, including photocatalysts, photonic devices and solar cells....... For example, electron holography is being used to study p-n junctions both in the presence and in the absence of light in order to assess electron beam induced charging and discharging effects during laser light exposure [3]. Here, we present results from ETEM studies of light-induced phenomena that include...

  11. Research on the tool holder mode in high speed machining

    Zhenyu, Zhao; Yongquan, Zhou; Houming, Zhou; Xiaomei, Xu; Haibin, Xiao

    2018-03-01

    High speed machining technology can improve the processing efficiency and precision, but also reduce the processing cost. Therefore, the technology is widely regarded in the industry. With the extensive application of high-speed machining technology, high-speed tool system has higher and higher requirements on the tool chuck. At present, in high speed precision machining, several new kinds of clip heads are as long as there are heat shrinkage tool-holder, high-precision spring chuck, hydraulic tool-holder, and the three-rib deformation chuck. Among them, the heat shrinkage tool-holder has the advantages of high precision, high clamping force, high bending rigidity and dynamic balance, etc., which are widely used. Therefore, it is of great significance to research the new requirements of the machining tool system. In order to adapt to the requirement of high speed machining precision machining technology, this paper expounds the common tool holder technology of high precision machining, and proposes how to select correctly tool clamping system in practice. The characteristics and existing problems are analyzed in the tool clamping system.

  12. Gender differentials in market participation among small-holder ...

    Gender differentials in market participation among small-holder cassava farmers ... The results showed that the female farmers participated and sold more cassava in the market than their male counterparts. ... facilitate faster delivery of farm produce especially perishable commodities such as ... AJOL African Journals Online.

  13. Small holder farmers coping strategies to household food insecurity ...

    This study has aimed at examining the small holder farmers' coping strategies to sustained household food insecurity and hunger in Southern Ethiopia (Sidama Zone). In order to collect the required input data, a comprehensive interview schedule was developed. The data were collected from 614 households who were ...

  14. Punishability of office-holders in environmental law

    Papier, H.J.

    1988-01-01

    The author deals with the question of criminal responsibility of office-holders in the field of environmental law. The provisions in secs. 324-330 of the Penal Code do not grant independent or origin protection from violation of the law. They depend on administrative law regulations. (WG) [de

  15. Small holder farmers coping strategies to household food insecurity ...

    Small holder farmers coping strategies to household food insecurity and hunger in Southern Ethiopia. ... Ethiopian Journal of Environmental Studies and Management ... The study further showed that households in the study area employ a range of coping strategies to respond to the high and sustained food insecurity and ...

  16. Socio-economic characteristics of small-holder farmers influencing ...

    Socio-economic characteristics of small-holder farmers influencing their utilisation of microcredit in the central agricultural zone of Cross River state. ... The findings revealed that about thirty – four percent (33.6%) of the crop farmers fell between 41-50 years while about 51% of the livestock farmers fell between 31-40 years.

  17. Failure analysis of vise jaw holders for hacksaw machine

    Essam Ali Al-Bahkali

    2018-01-01

    Full Text Available Failure analysis in mechanical components has been investigated in many studies in the last few years. Failure analysis and prevention are important functions in all engineering disciplines. Materials engineers are often the lead role in the analysis of failures, where a component or product fails in service or if a failure occurs during manufacturing or production processing. In any case, one must determine the cause of the failure to prevent future occurrences and/or to improve the performance of the device, component or structure. For example, the vise jaw holders of hacksaws can break due to accidental heavy loads or machine misuse. The parts that break are the stationary and movable vise jaw holders and the connecter power screw between the holders. To investigate the failure of these components, a three-dimensional finite element model for stress analysis was performed. First, the analysis identified the broken components of the hacksaw machine. In addition, the type of materials of the broken parts was identified, a CAD model was built, and the hacksaw mechanism was analyzed to determine the accurate applied loads on the broken parts. After analyzing the model using Abaqus CAE software, the results showed that the location of the high stresses was identical with the high-stress locations in the original, broken parts. Furthermore, the power screw was subjected to a high load, which deformed the power screw. Also, the stationary vise jaw holder was broken by impact because it was not touched by the power screw until the movable vise jaw holder broke. A conclusion is drawn from the failure analysis and a way to improve the design of the broken parts is suggested.

  18. NASA Biological Specimen Repository

    McMonigal, K. A.; Pietrzyk, R. A.; Sams, C. F.; Johnson, M. A.

    2010-01-01

    The NASA Biological Specimen Repository (NBSR) was established in 2006 to collect, process, preserve and distribute spaceflight-related biological specimens from long duration ISS astronauts. This repository provides unique opportunities to study longitudinal changes in human physiology spanning may missions. The NBSR collects blood and urine samples from all participating ISS crewmembers who have provided informed consent. These biological samples are collected once before flight, during flight scheduled on flight days 15, 30, 60, 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days after landing. The number of in-flight sessions is dependent on the duration of the mission. Specimens are maintained under optimal storage conditions in a manner that will maximize their integrity and viability for future research The repository operates under the authority of the NASA/JSC Committee for the Protection of Human Subjects to support scientific discovery that contributes to our fundamental knowledge in the area of human physiological changes and adaptation to a microgravity environment. The NBSR will institute guidelines for the solicitation, review and sample distribution process through establishment of the NBSR Advisory Board. The Advisory Board will be composed of representatives of all participating space agencies to evaluate each request from investigators for use of the samples. This process will be consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. Operations supporting the NBSR are scheduled to continue until the end of U.S. presence on the ISS. Sample distribution is proposed to begin with selections on investigations beginning in 2017. The availability of the NBSR will contribute to the body of knowledge about the diverse factors of spaceflight on human physiology.

  19. Rotating specimen rack repair

    Miller, G.E.; Rogers, P.J.; Nabor, W.G.; Bair, H.

    1984-01-01

    In 1980, an operator at the UCI TRIGA Reactor noticed difficulties with the rotation of the specimen rack. Investigations showed that the drive bearing in the rack had failed and allowed the bearings to enter the rack. After some time of operation in static mode it was decided that installation of a bearing substitute - a graphite sleeve - would be undertaken. Procedures were written and approved for removal of the rack, fabrication and installation of the sleeve, and re-installation of the rack. This paper describes these procedures in some detail. Detailed drawings of the necessary parts may be obtained from the authors

  20. Method for thinning specimen

    Follstaedt, David M.; Moran, Michael P.

    2005-03-15

    A method for thinning (such as in grinding and polishing) a material surface using an instrument means for moving an article with a discontinuous surface with an abrasive material dispersed between the material surface and the discontinuous surface where the discontinuous surface of the moving article provides an efficient means for maintaining contact of the abrasive with the material surface. When used to dimple specimens for microscopy analysis, a wheel with a surface that has been modified to produce a uniform or random discontinuous surface significantly improves the speed of the dimpling process without loss of quality of finish.

  1. Multilevel stake holder consensus building in radioactive waste management

    Dreimanis, Andrejs

    2008-01-01

    Full text: The increased demand of our society to its quality of life, global security and environmental safety as well as to observing a basic ethical principle of equity have advanced our attitude towards the recent proposals to develop shared multinational projects in the use of nuclear energy technologies, in particular, to: a) Siting of shared deep repositories for high-level radioactive waste (RW) and spent nuclear fuel safe disposal. In turn, arrangement of multinational facilities requires to gain more complex consensus between all involved parties. Method: We propose an interdisciplinary synergetic approach to multilevel consensus building for siting and construction of shared multinational repositories for RW deep disposal, based on self-organization (SO) of various stake holders, chaos and fuzziness concepts as well as Ashby principle of requisite variety. In the siting of a multi-national repository there appears an essential novel component of stake holder consensus building, namely: to reach consent - political, social, economic, ecological - among international partners, in addition to solving the whole set of intra-national consensus building items. An entire partnering country is considered as a national stake holder, represented by the national government, being faced to simultaneous seeking an upward (international) and a downward (intra-national) consensus in a psychologically stressed environment, having possibly diverse political, economic and social interests. Main Results: Following inferences about building of multilevel consensus are developed: 1) The basis of synergetic approach to stake holder interaction - informational SO, by forming a knowledge-creating stake holder community via cooperation and competition among individuals, public bodies/groups, companies, institutions; 2) Building of international stake holder consensus could be promoted by activating and diversifying multilateral interactions between intra- and international stake

  2. 30 CFR 250.1010 - General requirements for pipeline right-of-way holders.

    2010-07-01

    ... United States or its lessees or right-of-way holders, as the case may be, the full value of all damages...). The right-of-way holder shall make available all records relative to the design, construction... site. Furthermore, the holder is responsible for accidents or damages which might occur as a result of...

  3. 77 FR 69650 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    2012-11-20

    ... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... information collection requirement concerning the Holders or Containers which Enter the United States Duty... concerning the following information collection: Title: Holders or Containers which Enter the United States...

  4. Smart Farming: Including Rights Holders for Responsible Agricultural Innovation

    Kelly Bronson

    2018-01-01

    This article draws on the literature of responsible innovation to suggest concrete processes for including rights holders in the “smart” agricultural revolution. It first draws upon historical agricultural research in Canada to highlight how productivist values drove seed innovations with particular consequences for the distribution of power in the food system. Next, the article uses document analysis to suggest that a similar value framework is motivating public investment in smart farming i...

  5. Recent validation tests of the Edelweiss II detector holders

    Schwamm, F.; Chapellier, M.; Herve, S.; Karolak, M.; Navick, X.-F.

    2006-01-01

    A very good understanding of noise sources is highly important for the sensitivity of a dark matter search experiment. One of these noise contributions in the Edelweiss experiment could be the microphonics and temperature variations caused by vibrations of the cryostat. Recent studies complement an earlier work in describing the effect of the Edelweiss II detector holders on the amplitude of the vibrations seen by the detector. The results of these studies will be presented in this article

  6. Towards a compact and precise sample holder for macromolecular crystallography.

    Papp, Gergely; Rossi, Christopher; Janocha, Robert; Sorez, Clement; Lopez-Marrero, Marcos; Astruc, Anthony; McCarthy, Andrew; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent

    2017-10-01

    Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of mini

  7. Sample holder for studying temperature dependent particle guiding

    Bereczky, R.J.; Toekesi, K.; Kowarik, G.; Aumayr, F.

    2011-01-01

    Complete text of publication follows. The so called guiding effect is a complex process involving the interplay of a large number of charged particles with a solid. Although many research groups joined this field and carried out various experiments with insulator capillaries many details of the interactions are still unknown. We investigated the temperature dependence of the guiding since it opens new possibilities both for a fundamental understanding of the guiding phenomenon and for applications. For the temperature dependent guiding experiments a completely new heatable sample holder was designed. We developed and built such a heatable sample holder to make accurate and reproducible studies of the temperature dependence of the ion guiding effect possible. The target holder (for an exploded view see Fig. 1) consists of two main parts, the front and the back plates. The two plates of the sample holder, which function as an oven, are made of copper. These parts surround the capillary in order to guarantee a uniform temperature along the whole tube. The temperature of the copper parts is monitored by a K-Type thermocouple. Stainless steel coaxial heaters surrounding the oven are used for heating. The heating power up to a few watts is regulated by a PID controller. Cooling of the capillary is achieved by a copper feed-through connected to a liquid nitrogen bath outside the UHV chamber. This solution allows us to change the temperature of the sample from -30 deg C up to 90 deg C. Our experiments with this newly developed temperature regulated capillary holder show that the glass temperature (i.e. conductivity) can be used to control the guiding properties of the glass capillary and adjust the conditions from guiding at room temperature to simple geometrical transmission at elevated temperatures. This holds the promise to investigate the effect of conductivity on particle transport (build-up and removal of charge patches) through capillaries in more details

  8. Splitting tests on rock specimens

    Davies, J D; Stagg, K G

    1970-01-01

    Splitting tests are described for a square-section sandstone specimens line loaded through steel or timber packings on the top face and supported on the bottom face either on similar packings (type A specimen) or directly on the lower platen plate of the testing machine (type B specimens). The stress distribution across the vertical central plane and the horizontal central plane were determined from a linear elastic finite element analysis for both types. Two solutions were obtained for the type B specimen: one assuming no friction between the base of the specimen and the platen plate and the other assuming no relative slip between the surfaces. Vertical and horizontal strains were measured at the center of the specimens for all loads up to failure.

  9. Janka hardness using nonstandard specimens

    David W. Green; Marshall Begel; William Nelson

    2006-01-01

    Janka hardness determined on 1.5- by 3.5-in. specimens (2×4s) was found to be equivalent to that determined using the 2- by 2-in. specimen specified in ASTM D 143. Data are presented on the relationship between Janka hardness and the strength of clear wood. Analysis of historical data determined using standard specimens indicated no difference between side hardness...

  10. Smart Farming: Including Rights Holders for Responsible Agricultural Innovation

    Kelly Bronson

    2018-02-01

    Full Text Available This article draws on the literature of responsible innovation to suggest concrete processes for including rights holders in the “smart” agricultural revolution. It first draws upon historical agricultural research in Canada to highlight how productivist values drove seed innovations with particular consequences for the distribution of power in the food system. Next, the article uses document analysis to suggest that a similar value framework is motivating public investment in smart farming innovations. The article is of interest to smart farming’s decision makers (from farmers to governance actors and a broader audience – anyone interested in engendering equity through innovation-led societal transitions.

  11. Holder pasteurization affects S100B concentrations in human milk.

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Visser, Gerard H A; Gazzolo, Diego

    2018-02-01

    Donor milk (DM) represents an important nutrition source for high-risk newborns. Holder pasteurization (HoP) is the most recommended procedure for DM treatment, providing a good compromise between microbiological safety and biological quality. HoP was previously shown to affect DM cytokines, growth factors and hormones levels, whilst no data concerning the possible effects of HoP on neurobiomarkers (NB) are available. Therefore, our study investigated whether the concentration in DM of a well-known NB involved in brain development/damage, namely S100B, changes due to HoP. We conducted a pretest-test study in 11 mothers, whose DM samples were sub-divided into two parts: the first was immediately frozen (-80 °C); the second was pasteurized with Holder method before freezing. S100B DM levels were measured using a commercially available immunoluminometric assay. S100B protein was detected in all milk samples. Results showed significant differences between groups (p pasteurization stresses and the need to develop new storage techniques to preserve the biological quality of human milk.

  12. Note: A scanning electron microscope sample holder for bidirectional characterization of atomic force microscope probe tips

    Eisenstein, Alon; Goh, M. Cynthia [Department of Chemistry and Institute for Optical Sciences, University of Toronto, 80 St. George Street, Toronto M5S 3H6 (Canada)

    2012-03-15

    A novel sample holder that enables atomic force microscopy (AFM) tips to be mounted inside a scanning electron microscopy (SEM) for the purpose of characterizing the AFM tips is described. The holder provides quick and easy handling of tips by using a spring clip to hold them in place. The holder can accommodate two tips simultaneously in two perpendicular orientations, allowing both top and side view imaging of the tips by the SEM.

  13. An automated tensile machine for small specimens heavily neutron irradiated in FFTF/MOTA

    Kohyama, Akira; Sato, Shinji; Hamada, Kenichi

    1993-01-01

    The objective of this work is to develop a fully automated tensile machine for post-irradiation examination (PIE) of Fast Flux Test Facility (FFTF)/Materials Open Test Assembly (MOTA) irradiated miniature tension specimens. The anticipated merit of the automated tensile machine is to reduce damage to specimens during specimen handling for PIE and to reduce exposure to radioactive specimens. This machine is designed for testing at elevated temperatures, up to 873 K, in a vacuum or in an inert gas environment. Twelve specimen assemblies are placed in the vacuum chamber that can be tested successively in a fully automated manner. A unique automated tensile machine for the PIE of FFTF/MOTA irradiated specimens, the Monbusho Automated Tensile Machine (MATRON) consists of a test frame with controlling units and an automated specimen-loading apparatus. The qualification of the test frame has been completed, and the results have satisfied the machine specifications. The capabilities of producing creep and relaxation data have been demonstrated for Cu, Al, 316SS, and ferritic steels. The specimen holders for the three-point bending test and the small bulge test (small punch test; SP test) were also designed and produced

  14. Screen-film specimen radiography

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  15. DNA extraction from herbarium specimens.

    Drábková, Lenka Záveská

    2014-01-01

    With the expansion of molecular techniques, the historical collections have become widely used. Studying plant DNA using modern molecular techniques such as DNA sequencing plays an important role in understanding evolutionary relationships, identification through DNA barcoding, conservation status, and many other aspects of plant biology. Enormous herbarium collections are an important source of material especially for specimens from areas difficult to access or from taxa that are now extinct. The ability to utilize these specimens greatly enhances the research. However, the process of extracting DNA from herbarium specimens is often fraught with difficulty related to such variables as plant chemistry, drying method of the specimen, and chemical treatment of the specimen. Although many methods have been developed for extraction of DNA from herbarium specimens, the most frequently used are modified CTAB and DNeasy Plant Mini Kit protocols. Nine selected protocols in this chapter have been successfully used for high-quality DNA extraction from different kinds of plant herbarium tissues. These methods differ primarily with respect to their requirements for input material (from algae to vascular plants), type of the plant tissue (leaves with incrustations, sclerenchyma strands, mucilaginous tissues, needles, seeds), and further possible applications (PCR-based methods or microsatellites, AFLP).

  16. 19 CFR 134.22 - General rules for marking of containers or holders.

    2010-04-01

    ... required for any good of a NAFTA country which is a usual container. (c) Containers or holders bearing a U.S. address. Containers or holders of imported merchandise bearing the name and address of an... shaped or fitted to contain a specific good or set of goods such as a camera case or an eyeglass case, or...

  17. A sample holder for the study of isothermal heat of hydration of cement

    Hansen, Per Freiesleben; Jensen, Ole Mejlhede

    1998-01-01

    Different techniques for measuring heat of hydration of cement are discussed, and a sample holder designed specially for measuring isothermal heat of hydration is described. A particular characteristic of the sample holder is the vacuum mixing technique which ensures a momentary and homogeneous...

  18. 7 CFR 1463.105 - Base quota levels for eligible quota holders.

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Base quota levels for eligible quota holders. 1463.105 Section 1463.105 Agriculture Regulations of the Department of Agriculture (Continued) COMMODITY... TRANSITION PROGRAM Tobacco Transition Payment Program § 1463.105 Base quota levels for eligible quota holders...

  19. 78 FR 9720 - Agency Information Collection Activities: Holders or Containers Which Enter the United States...

    2013-02-11

    ... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... or Containers which enter the United States Duty Free. This is a proposed extension of an information..., or other technological techniques or other forms of information. Title: Holders or Containers which...

  20. 7 CFR 762.144 - Repurchase of guaranteed portion from a secondary market holder.

    2010-01-01

    ... discrepancy is resolved. (iii) In the case of a request for Agency purchase, the Agency will only pay interest... and the amount due the holder. (ii) Any discrepancy between the amount claimed by the holder and the... approved by the Agency. The Agency will not participate in resolution of any such discrepancy. When there...

  1. 14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Holders of type certificates: Fuel tank... Tank Flammability § 26.33 Holders of type certificates: Fuel tank flammability. (a) Applicability. This... part 25 of this chapter. (2) Exception. This paragraph (b) does not apply to— (i) Fuel tanks for which...

  2. 26 CFR 1.860C-1 - Taxation of holders of residual interests.

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.860C-1 Taxation of holders...

  3. 14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders

    2010-01-01

    ... K of this chapter. The training requirements for various categories of persons are defined by job... to persons actually performing the job function. Training requirements for certificate holders.... The method of delivering the training will be determined by the certificate holder. The certificate...

  4. A MEMS-based heating holder for the direct imaging of simultaneous in-situ heating and biasing experiments in scanning/transmission electron microscopes.

    Mele, Luigi; Konings, Stan; Dona, Pleun; Evertz, Francis; Mitterbauer, Christoph; Faber, Pybe; Schampers, Ruud; Jinschek, Joerg R

    2016-04-01

    The introduction of scanning/transmission electron microscopes (S/TEM) with sub-Angstrom resolution as well as fast and sensitive detection solutions support direct observation of dynamic phenomena in-situ at the atomic scale. Thereby, in-situ specimen holders play a crucial role: accurate control of the applied in-situ stimulus on the nanostructure combined with the overall system stability to assure atomic resolution are paramount for a successful in-situ S/TEM experiment. For those reasons, MEMS-based TEM sample holders are becoming one of the preferred choices, also enabling a high precision in measurements of the in-situ parameter for more reproducible data. A newly developed MEMS-based microheater is presented in combination with the new NanoEx™-i/v TEM sample holder. The concept is built on a four-point probe temperature measurement approach allowing active, accurate local temperature control as well as calorimetry. In this paper, it is shown that it provides high temperature stability up to 1,300°C with a peak temperature of 1,500°C (also working accurately in gaseous environments), high temperature measurement accuracy (in-situ S/TEM imaging experiments, but also elemental mapping at elevated temperatures using energy-dispersive X-ray spectroscopy (EDS). Moreover, it has the unique capability to enable simultaneous heating and biasing experiments. © 2016 Wiley Periodicals, Inc.

  5. Remote replacement of materials open-test assembly specimens at the FFTF/IEM cell

    Gibbons, P.W.; Ramsey, E.B.

    1990-01-01

    The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and materials experiments. The materials open-test assembly (MOTA) is brought to the IEM cell for materials test specimen removal. The specimens are shipped to the materials laboratory for sorting and installation in new specimen holders and then returned within 10 days to the IEM cell where they are installed in a new MOTA vehicle for further irradiation. Reconstituting a MOTA is a challenging remote operation involving dozens of steps and two separate facilities. Handling and disassembling sodium-wetted components pose interesting handling, cleaning, and disposal challenges. The success of this system is evidenced by its timely completion in the critical path of FFTF outage schedules

  6. Fatigue damage observed non-destructively in fibre composite coupon test specimens by X-ray CT

    Jespersen, Kristine Munk; Mikkelsen, Lars Pilgaard

    2016-01-01

    This study presents a method for monitoring the 3D fatigue damage progression on a micro-structural level in a glass fibre/polymer coupon test specimen by means of laboratory X-ray Computed Tomography (CT). A modified mount and holder made for the standard test samples to fit into the X-ray CT...... scanner along with a tension clamp solution is presented. Initially, the same location of the test specimen is inspected by ex-situ X-ray CT during the fatigue loading history, which shows the damage progression on a micro-structural level. The openings of individual uni-directional (UD) fibre fractures...

  7. STATISTICAL ASSESSMENT OF CAREERS OF DOCTORATE HOLDERS SURVEY BY CORRESPONDENCE ANALYSIS: THE CASE OF TURKEY

    Zerrin AŞAN GREENACRE

    2018-01-01

    Nowadays, doctorate holders are not only academician and researcher, also they play roles across a wide range of working areas within society. These areas are increasing multiway. The aim of this study is to give statistical evaluation careers of doctorate holders survey using  the correspondence analysis with supplementary variables. In this paper  we focused on careers of doctorate holders  in Turkey. It was held a survey by  Turkish   Statistical Institute on this s...

  8. Investigation of a flame holder geometry effect on flame structure in non-premixed combustion

    Hashemi, S. A.; Hajialigol, N.; Fattahi, A.; Heydari, R.; Mazaheri, K.

    2013-01-01

    In this paper the effect of flame holder geometry on flame structure is studied. The obtained numerical results using realizable k-ε and β-PDF models show a good agreement with experimental data. The results show that increasing in flame holder length decreases flame length and increases flame temperature. Additionally, it is observed that flame lengths decrease by increasing in flame holder radius and increase for larger radii. Furthermore in various radii, the flame temperature is higher for smaller flame lengths. It was found that behavior of flame structure is mainly affected by the mass flow rate of hot gases that come near the reactant by the recirculation zone.

  9. Investigation of a flame holder geometry effect on flame structure in non-premixed combustion

    Hashemi, S. A.; Hajialigol, N.; Fattahi, A.; Heydari, R. [University of Kashan, Kashan (Iran, Islamic Republic of); Mazaheri, K. [University of Tarbiat Moddares, Tehran (Iran, Islamic Republic of)

    2013-11-15

    In this paper the effect of flame holder geometry on flame structure is studied. The obtained numerical results using realizable k-ε and β-PDF models show a good agreement with experimental data. The results show that increasing in flame holder length decreases flame length and increases flame temperature. Additionally, it is observed that flame lengths decrease by increasing in flame holder radius and increase for larger radii. Furthermore in various radii, the flame temperature is higher for smaller flame lengths. It was found that behavior of flame structure is mainly affected by the mass flow rate of hot gases that come near the reactant by the recirculation zone.

  10. A new holder and surface MRI coil for the examination of the newborn infant hip

    Krasny, R. (Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany)); Casser, H.R. (Dept. of Orthopedics, Univ. of Technology, Aachen (Germany)); Requardt, H. (Siemens AG, Erlangen (Germany)); Botschek, A. (Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany))

    1993-11-01

    A special holder was developed for examination of the infant hip joint using MRI. This holder allows the infant hip joint to be examined both in a neutral position and in various defined functional positions. A special integrated surface coil, also developed for this purpose, provides the high spatial resolution required for assessment of the fine joint structures. Thirty infants were examined and the new device has proved useful in advanced hip dysplasia, therapy-resistant subluxation and luxation, and for operative therapy planning (reconstruction of the acetabular roof, redirectional osteotomies). Interpretation errors due to misprojection can be eliminated to a large extent since the holder allows standardized and reproducible positioning. (orig.)

  11. Automatic gamma radiation scanning device and feed mechanism for plural sample holders

    Byrd, W.J.

    1976-01-01

    Apparatus is disclosed for measuring the level of gamma radiation contained in a plurality of biological samples which are located on the fibrous sheet member carried by a sample holder. The apparatus is adapted to count the radiation level of the number of closely spaced samples located in rows and columns on the sheet by automatically sequencing through the individual samples within the rows and to advance the holder to bring successive rows into proximity with the detector. The detector is moved from sample to sample within the rows, although a number of detectors can be employed. A plurality of sample holders are automatically advanced to the detector. 25 claims, 5 drawing figures

  12. Gasket-holder to put in place gaskets for connection of pipes with clamp fittings

    Fiori, R.

    1989-01-01

    Gasket-holder comprising 2 arms with tongues holding the gasket and fixing devices on a pipe clamp fitting and centering means. Application is made to fit circular gaskets on pipe with conic end in adverse environment [fr

  13. 32 CFR 767.9 - Content of permit holder's final report.

    2010-07-01

    ... RULES APPLICATION GUIDELINES FOR ARCHEOLOGICAL RESEARCH PERMITS ON SHIP AND AIRCRAFT WRECKS UNDER THE.... The permit holder's final report shall include the following: (a) A site history and a contextual...

  14. EFFECTIVELY SEARCHING SPECIMEN AND OBSERVATION DATA WITH TOQE, THE THESAURUS OPTIMIZED QUERY EXPANDER

    Anton Güntsch

    2009-09-01

    Full Text Available Today’s specimen and observation data portals lack a flexible mechanism, able to link up thesaurus-enabled data sources such as taxonomic checklist databases and expand user queries to related terms, significantly enhancing result sets. The TOQE system (Thesaurus Optimized Query Expander is a REST-like XML web-service implemented in Python and designed for this purpose. Acting as an interface between portals and thesauri, TOQE allows the implementation of specialized portal systems with a set of thesauri supporting its specific focus. It is both easy to use for portal programmers and easy to configure for thesaurus database holders who want to expose their system as a service for query expansions. Currently, TOQE is used in four specimen and observation data portals. The documentation is available from http://search.biocase.org/toqe/.

  15. Laser Plasma Soft X-ray Microscope with Wolter Mirrors for Observation of Biological Specimens in Air

    Hoshino, Masato; Aoki, Sadao

    2006-02-01

    A laser plasma soft X-ray microscope with Wolter mirrors was developed so that specimens could be set in the atmosphere. Silicon nitride membranes 100 nm thick were used as vacuum-tight windows. Using relatively large windows (0.46× 0.46 mm2), an adequate working distance for samples, which was approximately 1.2 mm, was assured. The endurance of the vacuum-tight window was measured briefly. Dry biological cells could be observed with resolution better than 100 nm. A preliminary observation of wet biological cells was carried out using a wet environmental sample holder which was composed of only two sheets of silicon nitride membrane. An X-ray micrograph of wet red blood cells from a chicken was obtained without apparent effects of radiation damage. The properties of a vacuum-tight window and a wet sample holder are discussed.

  16. Laser plasma soft x-ray microscope with Wolter mirrors for observation of biological specimens in air

    Hoshino, Masato; Aoki, Sadao

    2006-01-01

    A laser plasma soft X-ray microscope with Wolter mirrors was developed so that specimens could be set in the atmosphere. Silicon nitride membranes 100 nm thick were used as vacuum-tight windows. Using relatively large windows (0.46 x 0.46 mm 2 ), an adequate working distance for samples, which was approximately 1.2 mm, was assured. The endrance of the vacuum-tight window was measured briefly. Dry biological cells could be observed with resolution better than 100 nm. A preliminary observation of wet biological cells was carried out using a wet environmental sample holder which was composed of only two sheets of silicon nitride membrane. An X-ray micrograph of wet red blood cells from a chicken was obtained without apparent effects of radiation damage. The properties of a vacuum-tight window and a wet sample holder are discussed. (author)

  17. Collagen Quantification in Tissue Specimens.

    Coentro, João Quintas; Capella-Monsonís, Héctor; Graceffa, Valeria; Wu, Zhuning; Mullen, Anne Maria; Raghunath, Michael; Zeugolis, Dimitrios I

    2017-01-01

    Collagen is the major extracellular protein in mammals. Accurate quantification of collagen is essential in the biomaterials (e.g., reproducible collagen scaffold fabrication), drug discovery (e.g., assessment of collagen in pathophysiologies, such as fibrosis), and tissue engineering (e.g., quantification of cell-synthesized collagen) fields. Although measuring hydroxyproline content is the most widely used method to quantify collagen in biological specimens, the process is very laborious. To this end, the Sircol™ Collagen Assay is widely used due to its inherent simplicity and convenience. However, this method leads to overestimation of collagen content due to the interaction of Sirius red with basic amino acids of non-collagenous proteins. Herein, we describe the addition of an ultrafiltration purification step in the process to accurately determine collagen content in tissues.

  18. Notch effects in uniaxial tension specimens

    Delph, T.J.

    1979-03-01

    Results of a literature survey on the effect of notches on the time-dependent failure of uniaxial tension specimens at elevated temperatures are presented. Particular attention is paid to the failure of notched specimens containing weldments

  19. Measurements and Counts for Notacanthidae Specimens

    National Oceanic and Atmospheric Administration, Department of Commerce — Taxonomic data were collected for specimens of deep-sea spiny eels (Notacanthidae) from the Hawaiian Ridge by Bruce C. Mundy. Specimens were collected off the north...

  20. Brittle Fracture Behaviors of Large Die Holders Used in Hot Die Forging

    Weifang Zhang

    2017-05-01

    Full Text Available Brittle fracture of large forging equipment usually leads to catastrophic consequences. To avoid this kind of accident, the brittle fracture behaviors of a large die holder were studied by simulating the practical application. The die holder is used on the large die forging press, and it is made of 55NiCrMoV7 hot-work tool steel. Detailed investigations including mechanical properties analysis, metallographic observation, fractography, transmission electron microscope (TEM analysis and selected area electron diffraction (SAED were conducted. The results reveal that the material generated a large quantity of large size polyhedral M23C6 (M: Fe and Cr mainly and elongated M3C (M: Fe mainly carbides along the martensitic lath boundaries when the die holder was recurrently tempered and water-cooled at 250 °C during the service. The large size carbides lead to the material embrittlement and impact toughness degradation, and further resulted in the brittle fracture of the die holder. Therefore, the operation specification must be emphasized to avoid the die holder being cooled by using water, which is aimed at accelerating the cooling.

  1. Evaluation of the uncertainty associated with sample holders in NAA measurements in LAN/IPEN

    Zahn, Guilherme S.; Ticianelli, Regina B.; Saiki, Mitiko; Genezini, Frederico A., E-mail: ticianelli@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In IPEN's Neutron Activation Laboratory (LAN/IPEN), thin stainless steel sample holders are used for gamma spectrometry in NAA measurements. This material is very practical, but its chemical composition may be troublesome, as it presents large amounts of elements with intermediate atomic number, with attenuation factors for low-energy gamma-rays that must not be neglected. In this study, count rates obtained using different sample holders were compared. To accomplish that, an Am-241 source, with 59-keV gamma emission, was used so that low-energy gamma attenuation differences can be determined. Moreover, in order to study the energy dependence of these differences, a Ho-166m source was also used. From these results, it was possible to analyze the experimental error associated to the variations between sample holders, with the aim of introducing an addictive term to the uncertainty analysis of comparative Neutron Activation Analysis results. (author)

  2. Thermal Stress FE Analysis of Large-scale Gas Holder Under Sunshine Temperature Field

    Li, Jingyu; Yang, Ranxia; Wang, Hehui

    2018-03-01

    The temperature field and thermal stress of Man type gas holder is simulated by using the theory of sunshine temperature field based on ASHRAE clear-sky model and the finite element method. The distribution of surface temperature and thermal stress of gas holder under the given sunshine condition is obtained. The results show that the thermal stress caused by sunshine can be identified as one of the important factors for the failure of local cracked oil leakage which happens on the sunny side before on the shady side. Therefore, it is of great importance to consider the sunshine thermal load in the stress analysis, design and operation of large-scale steel structures such as the gas holder.

  3. Stability of Cortisol and Cortisone in Human Breast Milk During Holder Pasteurization.

    van der Voorn, Bibian; de Waard, Marita; Dijkstra, Lisette R; Heijboer, Annemieke C; Rotteveel, Joost; van Goudoever, Johannes B; Finken, Martijn J J

    2017-12-01

    Human donor milk is the feeding of choice for preterm infants, when own mother's milk is not available. Holder pasteurization is necessary to secure the safety of donor milk, although it can affect milk quality by reduction of nutritional and bioactive components. Recently, research has focused on the potential role of breast milk glucocorticoids for infant development. At this moment, it is unknown whether pasteurization affects milk glucocorticoid levels. Therefore, we assessed whether Holder pasteurization, the most frequently used method nowadays, reduces breast milk cortisol and cortisone levels, using breast milk samples from 30 women who delivered at term. We found tight correlations between pre- and postpasteurization levels of cortisol (R = 0.99) and cortisone (R = 0.98), and good agreement in Passing and Bablok regression analysis. In conclusion, cortisol and cortisone in human term breast milk are not significantly affected by Holder pasteurization.

  4. Position of document holder and work related risk factors for neck pain among computer users: a narrative review.

    Ambusam, S; Baharudin, O; Roslizawati, N; Leonard, J

    2015-01-01

    Document holder is used as a remedy to address occupational neck pain among computer users. An understanding on the effects of the document holder along with other work related risk factors while working in computer workstation requires attention. A comprehensive knowledge on the optimal location of the document holder in computer use and associated work related factors that may contribute to neck pain reviewed in this article. A literature search has been conducted over the past 14 years based on the published articles from January 1990 to January 2014 in both Science Direct and PubMed databases. Medical Subject Headings (MeSH) keywords for search were neck muscle OR head posture OR muscle tension' OR muscle activity OR work related disorders OR neck pain AND/OR document location OR document holder OR source document OR copy screen holder.Document holder placed lateral to the screen was most preferred to reduce neck discomfort among occupational typists. Document without a holder was placed flat on the surface is least preferred. The head posture and muscle activity increases when the document is placed flat on the surface compared to when placed on the document holder. Work related factors such as static posture, repetitive movement, prolong sitting and awkward positions were the risk factors for chronic neck pain. This review highlights the optimal location for document holder for computer users to reduce neck pain. Together, the importance of work related risk factors for to neck pain on occupational typist is emphasized for the clinical management.

  5. Naval Reserve Force: Cost and Benefit Analysis of Reducing the Number of Naval Surface Reserve Force Operating Budget Holders

    Young, Eric

    1997-01-01

    .... This thesis examines one of Commander Naval Surface Reserve Force's initiatives for reducing the current number of Operating Budget holder's Comptroller Departments without sacrificing efficiency...

  6. Development of Reconstitution Technology for Surveillance Specimens

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  7. Increasing the Deep Drawability of Al-1050 Aluminum Sheet using Multi-Point Blank Holder

    Gavas, M.

    2006-01-01

    Full Text Available Aluminum alloys have been widely used in the fields of automobile and aerospace industries. Due to their bad cold-formability in deep drawing, a lot of forming methods have been implemented to increase the drawing height and the limiting drawing rate (LDR. The conventional deep drawing process is limited to a certain limit drawing ratio beyond which failure will ensue. The purpose of this experimental study is to examine the possibilities of increasing this limitation using the multi-point blank holder. The results from the experiments showed that the multi-point blank holder is effective way to promote deep drawability of Al-1050 sheet.

  8. Modeling returns to education and labour market outcomes of doctoral degree holders in Bulgaria

    Simeonova-Ganeva, Ralitsa; Panayotova, Nataliya; Ganev, Kaloyan

    2013-01-01

    In this study we present the theoretical framework of the so called Mincerian equations used for modelling returns to education. Then, we construct a conceptual framework which allows us to answer the question “What happens to doctoral degree holders in the labour market?”. We analyse data for about 45,000 PhD graduates in Bulgaria from the NSI survey Career development of PhD degree holders run in 2007, 2009, and 2010. An attempt is made to measure pay gaps in terms of gender and major of st...

  9. Research Amplitudo Vibration On Holder Due To The Process Of Lathe Nozzle Rocket RX 450

    Ediwan; Budi Djatmiko, Agus; Dody Arisandi, EfFendy; Purnomo, Heri; Ibadi, Mahfud

    2018-04-01

    The main function of the rocket nozzle is to convert the enthalpy efficiency from combustion gas to kinetic energy and also to make high velocity out of the gas. The rocket nozzle usually consists of a converging and diverging part. With a smaller area on the neck and enlarged at the exit area. The velocity flow through the nozzle enlarges into the speed of sound through the neck and then becomes super sonic in the divergent part. Nozzle making or machining using conventional lathes, first performed is drilling on a massive metal that is bonded to the veneer, then after a sufficient gap is done deep-boring. At the time of the process of lathe in the nozzle RX 450 there is an obstacle that is vibrating tool holder chisel or holder so it is worried about not precision of the process of lathe. This should not happen because it can cause failure in the latter for it needs to be studied and studied further so that the lathe process goes accordingly. The holder material of ST 60 with a modulus of elasticity 200 GPa and a nozzle material of AISI 4340 alloy steel with σyield = 470 MPa, Shear Modulus G = 80 GPa. The purpose of this research is to observe the amplitude of vibration on the holder due to RX- 450 nozzle lathe processing for the purpose of amplitude that occurs in accordance with the desired so that the nozzle structure is no damage process. The result of the research was obtained holder with length (L) 80cm, profile width (B) 5 cm, height of profile (H) 10 cm, turning machine ω = 8.98 rad / sec and natural holder frequency ωn = 89.8 rad / second, Amplitude of vibration of δ = 1.21 mm, while the amplitude of the design X = 1.22 mm From the results of this study it can be said that the holder of a chisel or holder can be used as a tool at the time of RX nozzle retrieval process and is quite safe because it works under the condition ω/ω n Rocket Payload "AKPV Engineering University of Wyoming 2009 )

  10. Design and burn-up analyses of new type holder for silicon neutron transmutation doping.

    Komeda, Masao; Arai, Masaji; Tamai, Kazuo; Kawasaki, Kozo

    2016-07-01

    We have developed a new silicon irradiation holder with a neutron filter to increase the irradiation efficiency. The neutron filter is made of an alloy of aluminum and B4C particles. We fabricated a new holder based on the results of design analyses. This filter has limited use in applications requiring prolonged use due to a decrease in the amount of (10)B in B4C particles. We investigated the influence of (10)B reduction on doping distribution in a silicon ingot by using the Monte Carlo Code MVP. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. A sample holder for in-house X-ray powder diffraction studies of protein powders

    Frankær, Christian Grundahl; Harris, Pernille; Ståhl, Kenny

    2011-01-01

    A sample holder for handling samples of protein for in-house X-ray powder diffraction (XRPD) analysis has been made and tested on lysozyme. The use of an integrated pinhole reduced the background, and good signal-to-noise ratios were obtained from only 7 l of sample, corresponding to approximatel...... 2-3 mg of dry protein. The sample holder is further adaptable to X-ray absorption spectroscopy (XAS) measurements. Both XRPD and XAS at the Zn K-edge were tested with hexameric Zn insulin....

  12. Histopathologic analysis of appendectomy specimens

    R Shrestha

    2012-03-01

    Full Text Available Background: Acute appendicitis is one of the common conditions requiring emergency surgery. A retrospective study was performed to determine various histopathological diagnoses, their demographics and the rates of perforated appendicitis, negative appendectomy and incidental appendectomy. Materials and Methods: Histopathological records of resected appendices submitted to histopathology department Chitwan medical college teaching hospital over the period of 2 yrs from May, 2009 to April 2011 were reviewed retrospectively. Results: Out of 930 specimens of appendix, appendicitis accounted for 88.8% with peak age incidence in the age group of 11 to 30 yrs in both sexes. Histopathologic diagnoses included acute appendicitis (45.6%, acute suppurative (20.8%, gangrenous (16.3%, perforated (1.7%, resolving /recurrent/non specific chronic appendicitis (2.5%, acute eosinophilic appendicitis (1.2%, periappendicitis (0.2%, and carcinoid tumour (0.1%. Other important coexisting pathologies were parasitic infestation (0.2% and Meckel’s diverticulum (0.2%. Negative appendectomy rate was 10.8% and three times more common in females with peak occurrence in the age group of 21-30 yrs. There were 10 cases of acute appendicitis in incidental appendectomies (2.5%, 24 cases with 7 times more common in females of age group of 31- 60 yrs. Conclusion: There is a high incidence of appendicitis in adolescents and young adults in central south region of Nepal. Negative appendectomy is also very common in females. Incidental appendectomy in elderly females may have preventive value. DOI: http://dx.doi.org/10.3126/jpn.v2i3.6025 JPN 2012; 2(3: 215-219

  13. Specimen size effects in Charpy impact testing

    Alexander, D.J.; Klueh, R.L.

    1989-01-01

    Full-size , half-size, and third-size specimens from several different steels have been tested as part of an ongoing alloy development program. The smaller specimens permit more specimens to be made from small trail heats and are much more efficient for irradiation experiments. The results of several comparisons between the different specimen sizes have shown that the smaller specimens show qualitatively similar behavior to large specimens, although the upper-shelf energy level and ductile-to-ductile transition temperature are reduced. The upper-shelf energy levels from different specimen sizes can be compared by using a simple volume normalization method. The effect of specimen size and geometry on the ductile-to-ductile transition temperature is more difficult to predict, although the available data suggest a simple shift in the transition temperature due to specimen size changes.The relatively shallower notch used in smaller specimens alters the deformation pattern, and permits yielding to spread back to the notched surface as well as through to the back. This reduces the constraint and the peak stresses, and thus the initiation of cleavage is more difficult. A better understanding of the stress and strain distributions is needed. 19 refs., 3 figs., 3 tabs

  14. Preliminary investigation of candidate specimens for the Egyptian environmental specimen bank

    Shawky, S.; Amer, H.; Schladot, J.D.; Ostapczuk, P.; Emons, H.; Abou El-Nour, F.

    2000-01-01

    In the frame of establishing an environmental monitoring program related to environmental specimen banking in egypt, some candidate specimens from the aquatic environment (Fish muscle, fish liver; mussels) were investigated. The selection of specimens and sampling sites is described. Specimens are chemically characterised with respect to some major and trace elements and the results are compared with data obtained from comparable specimens collected in aquatic ecosystems of germany

  15. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    Walker, B. J.; Miller, D. T.

    2017-01-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  16. Influence of endodontic instrument-holder on sterilization efficacy. A pilot in-vitro study.

    Angelo Carrizo

    2013-08-01

    Full Text Available Infection control is crucial in dentistry and various methods have been designed to assure its efficacy. However, little information exists regarding the influence it could have the instrument-holder of endodontic files. The aim of this research was to determine the influence of three instruments-holders on sterilization efficacy of endodontic files. Methods: A pilot in-vitro study. 60 endodontic files were contaminated by biomechanical preparation of extracted molars with periapical abscess, then processed according to the standard washing method. The endodontic files were divided into 3 groups (n=20 and assigned to 3 instrument-holders: Metallic box (MB, surgical gauze (SG and synthetic sponge (SS. Then, the files were packaged and sterilized by autoclaving (134°C/45min. Microbiological culture was performed in thioglycolate solution for each endodontic file (37ºC/5days. Results: The overall sterilization efficacy was 91.7%, 80% for MB, 100% for SS, and 95% for SG, with no statistically significant differences (p=0.06 between the groups. Conclusions: The lack of differences in the efficacy of sterilization may be due to the reduced sample; therefore, a full-size study is necessary to confirm this outcomes. The results of this study discourage the use of the MB as instrument-holder until a full-size study can confirm this data.

  17. Landscape effects on pollinator communities and pollination services in small-holder agroecosystems

    Zou, Yi; Bianchi, Felix J.J.A.; Jauker, Frank; Xiao, Haijun; Chen, Junhui; Cresswell, James; Luo, Shudong; Huang, Jikun; Deng, Xiangzheng; Hou, Lingling; Werf, van der Wopke

    2017-01-01

    Pollination by insects is key for the productivity of many fruit and non-graminous seed crops, but little is known about the response of pollinators to landscapes dominated by small-holder agriculture. Here we assess the relationships between landscape context, pollinator communities (density and

  18. 12 CFR 611.1210 - Advance notices-commencement resolution and notice to equity holders.

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Advance notices-commencement resolution and notice to equity holders. 611.1210 Section 611.1210 Banks and Banking FARM CREDIT ADMINISTRATION FARM..., within 10 days of adopting the commencement resolution, your bank and the other Farm Credit banks must...

  19. 13 CFR 120.651 - Claim to FTA by Registered Holder to replace Certificate.

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Claim to FTA by Registered Holder to replace Certificate. 120.651 Section 120.651 Business Credit and Assistance SMALL BUSINESS ADMINISTRATION BUSINESS LOANS Secondary Market Miscellaneous Provisions § 120.651 Claim to FTA by Registered...

  20. Assessing the authority of political office-holders : The leadership capital index

    Bennister, Mark; t Hart, Paul; Worthy, Benjamin

    2015-01-01

    This article argues that the extent to which political office-holders can effectively attain and wield authority is a function of the stock of ‘leadership capital’. Drawing on the concept of political capital, the article defines leadership capital as aggregate authority composed of three

  1. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 160A

    Walker, B. J. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, D. T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-06-06

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 160A which were measured by the Radiation Measurements Laboratory (RML).

  2. Do people really want freedom of choice? : Assessing preferences of pension holders

    van Dalen, Harry; Henkens, Kene

    2018-01-01

    Reforms of private pension plans across the world are involving the introduction of more options for pension holders to make choices to suit their preferences. Freedom of choice is not, however, a unidimensional concept despite being commonly perceived as such by policy makers. Using a unique panel

  3. 48 CFR 252.205-7000 - Provision of information to cooperative agreement holders.

    2010-10-01

    ... has an agreement with the Defense Logistics Agency to furnish procurement technical assistance to business entities. (b) The Contractor shall provide cooperative agreement holders, upon their request, with... defense contracts. The list shall include the business address, telephone number, and area of...

  4. Stability of Cortisol and Cortisone in Human Breast Milk During Holder Pasteurization

    van der Voorn, Bibian; de Waard, Marita; Dijkstra, Lisette R.; Heijboer, Annemieke C.; Rotteveel, Joost; van Goudoever, Johannes B.; Finken, Martijn J. J.

    2017-01-01

    Human donor milk is the feeding of choice for preterm infants, when own mother's milk is not available. Holder pasteurization is necessary to secure the safety of donor milk, although it can affect milk quality by reduction of nutritional and bioactive components. Recently, research has focused on

  5. Ebola Virus and Marburg Virus in Human Milk Are Inactivated by Holder Pasteurization.

    Hamilton Spence, Erin; Huff, Monica; Shattuck, Karen; Vickers, Amy; Yun, Nadezda; Paessler, Slobodan

    2017-05-01

    Potential donors of human milk are screened for Ebola virus (EBOV) using standard questions, but testing for EBOV and Marburg virus (MARV) is not part of routine serological testing performed by milk banks. Research aim: This study tested the hypothesis that EBOV would be inactivated in donor human milk (DHM) by standard pasteurization techniques (Holder) used in all North American nonprofit milk banks. Milk samples were obtained from a nonprofit milk bank. They were inoculated with EBOV (Zaire strain) and MARV (Angola strain) and processed by standard Holder pasteurization technique. Plaque assays for EBOV and MARV were performed to detect the presence of virus after pasteurization. Neither EBOV nor MARV was detectable by viral plaque assay in DHM or culture media samples, which were pasteurized by the Holder process. EBOV and MARV are safely inactivated in human milk by standard Holder pasteurization technique. Screening for EBOV or MARV beyond questionnaire and self-deferral is not needed to ensure safety of DHM for high-risk infants.

  6. CFD analysis of a scramjet combustor with cavity based flame holders

    Kummitha, Obula Reddy; Pandey, Krishna Murari; Gupta, Rajat

    2018-03-01

    Numerical analysis of a scramjet combustor with different cavity flame holders has been carried out using ANSYS 16 - FLUENT tool. In this research article the internal fluid flow behaviour of the scramjet combustor with different cavity based flame holders have been discussed in detail. Two dimensional Reynolds-Averaged Navier-Stokes governing(RANS) equations and shear stress turbulence (SST) k - ω model along with finite rate/eddy dissipation chemistry turbulence have been considered for modelling chemical reacting flows. Due to the advantage of less computational time, global one step reaction mechanism has been used for combustion modelling of hydrogen and air. The performance of the scramjet combustor with two different cavities namely spherical and step cavity has been compared with the standard DLR scramjet. From the comparison of numerical results, it is found that the development of recirculation regions and additional shock waves from the edge of cavity flame holder is increased. And also it is observed that with the cavity flame holder the residence time of air in the scramjet combustor is also increased and achieved stabilized combustion. From this research analysis, it has been found that the mixing and combustion efficiency of scramjet combustor with step cavity design is optimum as compared to other models.

  7. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Standard Procedure for Dose Assessment using the film holder NRPB/AERE and the film AGFA Monitoring 2/10

    Guillen, J.A.

    1998-07-01

    This paper describes the calculation method to assess dose and energy using the film holder from NRPB/AERE and the film Agfa Monitoring 2/10. Also includes all the steps since preparing the standard curve, fitting of calibration curve, dose assesment, description of filtration of the film holder and the form of the calibration curve

  9. Dose computation of Ti activated products for its qualification as a material for the sample holder in FBTR

    Ashok Kumar, G.V.S.; Kumar, R.; Venkatasubramani, C.R.; Acharya, R.; Reddy, A.V.R.

    2014-01-01

    Development of a Fast flux experimental facility with a sample holder facility in FBTR has been envisaged to carry out the studies on i) fast neutron activation analysis and ii) fission studies. This paper describes the facility in detail and dose computations that are to be generated due to long irradiation of the material of the sample holder i.e. titanium. (author)

  10. Bacteriological, biochemical, and immunological modifications in human colostrum after Holder pasteurisation.

    Espinosa-Martos, I; Montilla, A; de Segura, A Gómez; Escuder, D; Bustos, G; Pallás, C; Rodríguez, J M; Corzo, N; Fernández, L

    2013-05-01

    The objective of this work was to evaluate the effect of Holder pasteurisation of human colostrum on a variety of microbiological, biochemical, and immunological parameters. Colostrum samples from 10 donors, and 8 samples of mature milk used as controls, were heated at 62.5°C for 30 minutes. Bacterial counts and the concentration of furosine, lactose, myoinositol, glucose, lactulose, cytokines, and immunoglobulins were determined before and after the heat treatment. Mean bacterial counts in nonpasteurised colostrum samples oscillated between 2.72 and 4.13 log10 colony-forming units per millilitre in the agar media tested. Holder pasteurisation led to the destruction of the bacteria originally present in the samples. Furosine was detected in all samples before pasteurisation and increased significantly after the heat treatment (from 6.60 to 20.59 mg/100 g protein). Lactulose content was below the detection limit in nonpasteurised colostrum, but it was detected in all samples and quantified in 7 of them (from 10.68 to 38.02 mg/L) after Holder pasteurisation. Lactose, glucose, and myoinositol concentrations did not change after Holder pasteurisation. The concentrations of most cytokines and immunoglobulins were significantly higher in colostrum than in mature milk samples. Immunoglobulin content, both in colostrum and in milk samples, was reduced during pasteurisation, whereas, among cytokines, only macrophage inflammatory protein-1β, interleukin-7, and granulocyte-macrophage-colony-stimulating factor concentrations were affected by this heat treatment. Lactulose and furosine content could be used as heat treatment indicators in colostrum samples. Holder pasteurisation modified the immunological profile of both colostrum and mature milk.

  11. Highly identified power-holders feel responsible: The interplay between social identification and social power within groups.

    Scholl, Annika; Sassenberg, Kai; Ellemers, Naomi; Scheepers, Daan; de Wit, Frank

    2018-01-01

    Power relations affect dynamics within groups. Power-holders' decisions not only determine their personal outcomes, but also the outcomes of others in the group that they control. Yet, power-holders often tend to overlook this responsibility to take care of collective interests. The present research investigated how social identification - with the group to which both the powerful and the powerless belong - alters perceived responsibility among power-holders (and the powerless). Combining research on social power and social identity, we argue that power-holders perceive more responsibility than the powerless when strongly (rather than when weakly) identifying with the group. A study among leaders and an experiment supported this, highlighting that although power-holders are often primarily concerned about personal outcomes, they do feel responsible for considering others' interests when these others are included in the (social) self. © 2017 The British Psychological Society.

  12. 7 CFR 97.8 - Specimen requirements.

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Specimen requirements. 97.8 Section 97.8 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... required by the examiner to furnish representative specimens of the variety, or its flower, fruit, or seeds...

  13. Recent advances on Charpy specimen reconstitution techniques

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J., E-mail: aandrade@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  14. Recent advances on Charpy specimen reconstitution techniques

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J.

    2017-01-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  15. LPTR irradiation of LLL vanadium tensile specimens and LLL Nb--1Zr tensile specimens

    MacLean, S.C.; Rowe, C.L.

    1977-01-01

    The LPTR irradiation of 14 LLL vanadium tensile specimens and 14 LLL Nb-1Zr tensile specimens is described. Sample packaging, the irradiation schedule and neutron fluences for three energy ranges are given

  16. Common criteria among States for storage and use of dried blood spot specimens after newborn screening

    Carlo Petrini

    2012-06-01

    Full Text Available Biological samples collected in biobanks are a resource with significant research potential. The Italian Joint Group cNB - cNBBSV (National committee of Bioethics - National committee for Biosecurity, Biotechnologies and Life Sciences published a document reporting recommendations on storage and use of dried blood spot (DBS and on the development of a National Network of Regional Newborn Screening Repositories for collection of residual DBS. Several ethical questions (about consent, possible use of genetic information, unanticipated possible usages for research purposes rise from residual newborn screening specimens collections. Moreover, legal and ethical controversies are accentuated by the conflicts between the interests of sample donors, biobank holders, researchers and the public. To overcome these difficulties the identification of a few criteria for storage and research usage of DBS is crucial.

  17. 17 CFR 240.14a-7 - Obligations of registrants to provide a list of, or mail soliciting material to, security holders.

    2010-04-01

    ..., form of proxy or other communication to such holders, including to the extent known or reasonably... provided for under applicable state law identifying the proposal or other corporate action that will be the subject of the security holder's solicitation or communication and attesting that: (i) The security holder...

  18. Handling of biological specimens for electron microscopy

    Bullock, G.

    1987-01-01

    There are many different aspects of specimen preparation procedure which need to be considered in order to achieve good results. Whether using the scanning or transmission microscope, the initial handling procedures are very similar and are selected for the information required. Handling procedures and techniques described are: structural preservation; immuno-and histo-chemistry; x-ray microanalysis and autoradiography; dehydration and embedding; mounting and coating specimens for scanning electron microscopy; and sectioning of resin embedded material. With attention to detail and careful choice of the best available technique, excellent results should be obtainable whatever the specimen. 6 refs

  19. Evaluation of irradiated coating material specimens

    Lee, Yong Jin; Nam, Seok Woo; Cho, Lee Moon

    2007-12-01

    Evaluation result of irradiated coating material specimens - Coating material specimens radiated Gamma Energy(Co 60) in air condition. - Evaluation conditions was above 1 X 10 4 Gy/hr, and radiated TID 2.0 X 10 6 Gy. - The radiated coating material specimens, No Checking, Cracking, Flaking, Delamination, Peeling and Blistering. - Coating system at the Kori no. 1 and APR 1400 Nuclear power plant, evaluation of irradiated coating materials is in accordance with owner's requirement(2.0 X 10 6 Gy)

  20. Preparation and characterization of porous Mg-Zn-Ca alloy by space holder technique

    Annur, D.; Lestari, Franciska P.; Erryani, A.; Sijabat, Fernando A.; G. P. Astawa, I. N.; Kartika, I.

    2018-04-01

    Magnesium had been recently researched as a future biodegradable implant material. In the recent study, porous Mg-Zn-Ca alloys were developed using space holder technique in powder metallurgy process. Carbamide (10-20%wt) was added into Mg-6Zn-1Ca (in wt%) alloy system as a space holder to create porous structure material. Sintering process was done in a tube furnace under Argon atmosphere in 610 °C for 5 hours. Porous structure of the resulted alloy was examined using Scanning Electron Microscope (SEM), while the phase formation was characterized by X-ray diffraction analysis (XRD). Further, mechanical properties of porous Mg-Zn-Ca alloy was examined through compression testing. Microstructure characterization showed higher content of Carbamide in the alloy would give different type of pores. However, compression test showed that mechanical properties of Mg-Zn-Ca alloy would decrease significantly when higher content of carbamide was added.

  1. Head holder using negative pressure bag packed with plastic beads in xenon CT CBF study

    Araki, Yuzo; Sakai, Noboru

    2003-01-01

    Employing analysis of cerebral blood flow (CBF) confidence maps, we investigated the usefulness of a head holder using a negative pressure bag packed with plastic beads in a xenon CT CBF study. A total of 272 consecutive patients for the CBF study were enrolled and classified into 3 groups: 88 patients with a negative pressure bag (M group), 87 patients with an air pillow (A group), and 97 patients with a sponge pillow (S group). The degree of effect of head movements on the CBF measurement in each patient was expressed as a confidence value (mean of the confidence values at one CT slice). The mean of confidence value in the M group (0.461) was statistically lower than that in the A group (0.866) and that in the S group (1.043). These findings showed that the head holder described here was useful for obtaining CBF maps of high quality in a xenon CT CBF study. (author)

  2. Successive measurements of streaming potential and electroosmotic pressure with the same core-holder

    Yin, Chenggang; Hu, Hengshan; Yu, Chunhao; Wang, Jun

    2018-05-01

    Successive measurements of the streaming potential and electroosmotic pressure of each core sample are important for understanding the mechanisms of electrokinetic effects. In previous studies, one plug of the core-holder needs to be replaced in these two experiments, which causes the change of the fluid parameters and the boundary conditions in the core. We design a new core-holder to permit successive experiments without plug replacement, which ensures the consistency of the measurement environment. A two-direction harmonic pressure-driving source is accordingly designed. Using this new equipment, electrokinetic experiments conducted ten core samples at 0.4 mol/L NaCl solution. The results show good agreement between the electrokinetically deduced permeability and premeasured gas permeability. For high salinity saturated samples, the permeability can be inverted from electroosmotic effect instead of the streaming potential.

  3. Breeding snow: an instrumented sample holder for simultaneous tomographic and thermal studies

    Pinzer, B; Schneebeli, M

    2009-01-01

    To study the recrystallization processes during temperature gradient metamorphism of snow, we developed a sample holder that allows applying well-defined and stable thermal gradients to a snow sample while it is scanned in an x-ray micro-tomograph. To this end, both the thermal insulation of the sample as well as image contrast and resolution of the tomography had to be optimized. We solved this conflict by using thin aluminum cylinders in combination with highly insulating foam. This design is light, does not corrupt image quality and provides very good thermal decoupling from the environment. The sample holder was instrumented to measure the effective conductivity of the snow sample and calibrated using five materials of known conductivity. Finite element simulations were consistent with the calibration measurements and gave insight into the internal temperature and heat flux fields. With this setup, geometric and thermal evolution of snow under realistic thermal boundary conditions like alternating temperature gradients can be measured

  4. Experimental verification of a deep drawing tool system for adaptive blank holder pressure distribution

    Tommerup, Søren; Endelt, Benny Ørtoft

    2012-01-01

    In deep drawing, the strain path in the blank during the forming process can be significantly affected by application of temporal and spatial variation of the blank holder force. In this study, an active tool system capable of controlling the distribution of the blank holder force is presented...... which can be integrated into existing stacked deep drawing tools without need for modification of the press. A working system is presented consisting of a controller, designated volume displacement cavity pressure supply units and a shimming plate. It is applied to the deep drawing of a rectangular...... to the conventional shimming method using paper or metal shims between the tool plates. The tool system’s ability to influence the material flow is investigated by performing a series of deep drawing experiments. Eight different cavity pressure schemes are applied during the punch stroke and the scheme’s effects...

  5. A Modeling approach for analysis and improvement of spindle-holder-tool assembly dynamics

    Budak, Erhan; Ertürk, A.; Erturk, A.; Özgüven, H. N.; Ozguven, H. N.

    2006-01-01

    The most important information required for chatter stability analysis is the dynamics of the involved structures, i.e. the frequency response functions (FRFs) which are usually determined experimentally. In this study, the tool point FRF of a spindle-holder-tool assembly is analytically determined by using the receptance coupling and structural modification techniques. Timoshenko’s beam model is used for increased accuracy. The spindle is also modeled analytically with elastic supports repre...

  6. Research on scholarships holders who studied abroad and returned to Serbia

    Nena A. Vasojevic

    2017-10-01

    Full Text Available Knowledge has become the most valuable resource of the new era and the resource of the future. The intention of this study is to improve knowledge about the problem of migration of educated people from Serbia from the perspective of scholarship holders who, after being abroad, returned to their country. The aim of this research is to show the profile of the scholarship holders of post-academic and post-graduate students, who studied abroad and then returned to Serbia. Their motives for departure and return, as well as their perception of integration into the work environment in Serbia and utilization of their knowledge is presented. Methods: For the purpose of this research a questionnaire was constructed which was distributed online. Collected data were analysed using statistical tools. Results: This research has shown that the primary motive for education abroad is the desire for personal development. It has also been shown that an important factor for the return of students from abroad is their expectation of comparative advantage in the labour market and their belief of getting a desired job. Apart from this, it is shown that the scholarship holders only partially used the acquired knowledge and thus, do not have enough influence in the development of their organizations.Conclusion: The main research contribution is reflected in the improvement of the knowledge about the motivation of scholars to return from developed countries and highlighted problems which scholarship holders have after returning.Implications and research limitation: the results obtained can be generalised to countries that are passing or have recently moved a transition, and are similar in cultural characteristics. The present contains certain limitations that must be taken into account while interpreting final results. The most significant constraint is the sample size, but the obtained results, especially the motives of the scientific experts for a return to the country

  7. 50 CFR 14.24 - Scientific specimens.

    2010-10-01

    ..., POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS... international mail system. Provided, that this exception will not apply to any specimens or parts thereof taken...

  8. Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.

    Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak

    2018-01-01

    Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.

  9. An MR/MRI compatible core holder with the RF probe immersed in the confining fluid

    Shakerian, M.; Balcom, B. J.

    2018-01-01

    An open frame RF probe for high pressure and high temperature MR/MRI measurements was designed, fabricated, and tested. The open frame RF probe was installed inside an MR/MRI compatible metallic core holder, withstanding a maximum pressure and temperature of 5000 psi and 80 °C. The open frame RF probe was tunable for both 1H and 19F resonance frequencies with a 0.2 T static magnetic field. The open frame structure was based on simple pillars of PEEK polymer upon which the RF probe was wound. The RF probe was immersed in the high pressure confining fluid during operation. The open frame structure simplified fabrication of the RF probe and significantly reduced the amount of polymeric materials in the core holder. This minimized the MR background signal detected. Phase encoding MRI methods were employed to map the spin density of a sulfur hexafluoride gas saturating a Berea core plug in the core holder. The SF6 was imaged as a high pressure gas and as a supercritical fluid.

  10. New tool holder design for cryogenic machining of Ti6Al4V

    Bellin, Marco; Sartori, Stefano; Ghiotti, Andrea; Bruschi, Stefania

    2017-10-01

    The renewed demand of increasing the machinability of the Ti6Al4V titanium alloy to produce biomedical and aerospace parts working at high temperature has recently led to the application of low-temperature coolants instead of conventional cutting fluids to increase both the tool life and the machined surface integrity. In particular, the liquid nitrogen directed to the tool rake face has shown a great capability of reducing the temperature at the chip-tool interface, as well as the chemical interaction between the tool coating and the titanium to be machined, therefore limiting the tool crater wear, and improving, at the same time, the chip breakability. Furthermore, the nitrogen is a safe, non-harmful, non-corrosive, odorless, recyclable, non-polluting and abundant gas, characteristics that further qualify it as an environmental friendly coolant to be applied to machining processes. However, the behavior of the system composed by the tool and the tool holder, exposed to the cryogenics temperatures may represent a critical issue in order to obtain components within the required geometrical tolerances. On this basis, the paper aims at presenting the design of an innovative tool holder installed on a CNC lathe, which includes the cryogenic coolant provision system, and which is able to hinder the part possible distortions due to the liquid nitrogen adduction by stabilizing its dimensions through the use of heating cartridges and appropriate sensors to monitor the temperature evolution of the tool holder.

  11. Inactivation of high-risk human papillomaviruses by Holder pasteurization: implications for donor human milk banking.

    Donalisio, Manuela; Cagno, Valeria; Vallino, Marta; Moro, Guido E; Arslanoglu, Sertac; Tonetto, Paola; Bertino, Enrico; Lembo, David

    2014-01-01

    Several studies have recently reported the detection of oncogenic human papillomaviruses (HPV) in human milk of a minority of lactating mothers. These findings raised safety concerns in the context of human donor milk banking given the potential risk of HPV transmission to recipient infants. The aim of this study was to investigate whether the Holder pasteurization, a procedure currently in use in human donor milk banks for milk pasteurization, completely inactivates high-risk and low-risk HPV. HPV pseudoviruses (PsV) were generated, spiked into cell culture medium or donor human milk and subjected to thermal inactivation. HPV PsV infectivity and morphological integrity was analyzed by cell-based assay and by electron microscopy, respectively. The Holder pasteurization completely inactivated the infectivity of high-risk (types 16 and 18) and low-risk (type 6) HPV both in cell culture medium and in human milk causing PsV particle disassembly. The results presented here indicate that the Holder pasteurization is an efficient procedure to inactivate high-risk and low-risk HPV thus preventing the potential risk of their transmission through human donor milk.

  12. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  13. Specimen environments in thermal neutron scattering experiments

    Cebula, D.J.

    1980-11-01

    This report is an attempt to collect into one place outline information concerning the techniques used and basic design of sample environment apparatus employed in neutron scattering experiments. Preliminary recommendations for the specimen environment programme of the SNS are presented. The general conclusion reached is that effort should be devoted towards improving reliability and efficiency of operation of specimen environment apparatus and developing systems which are robust and easy to use, rather than achieving performance at the limits of technology. (author)

  14. Thermal property testing technique on micro specimen

    Baba, Tetsuya; Kishimoto, Isao; Taketoshi, Naoyuki

    2000-01-01

    This study aims at establishment of further development on some testing techniques on the nuclear advanced basic research accumulated by the National Research Laboratory of Metrology for ten years. For this purpose, a technology to test heat diffusion ratio and specific heat capacity of less than 3 mm in diameter and 1 mm in thickness of micro specimen and technology to test heat diffusion ratio at micro area of less than 1 mm in area along cross section of less than 10 mm in diameter of column specimen were developed to contribute to common basic technology supporting the nuclear power field. As a result, as an element technology to test heat diffusion ratio and specific heat capacity of the micro specimen, a specimen holding technique stably to hold a micro specimen with 3 mm in diameter could be developed. And, for testing the specific heat capacity by using the laser flush differential calorimetry, a technique to hold two specimen of 5 mm in diameter at their proximities was also developed. In addition, by promoting development of thermal property data base capable of storing thermal property data obtained in this study and with excellent workability in this 1998 fiscal year a data in/out-put program with graphical user interface could be prepared. (G.K.)

  15. Comparative study on Charpy specimen reconstitution techniques

    Bourdiliau, B.; Decroix, G.-M.; Averty, X.; Wident, P.; Bienvenu, Y.

    2011-01-01

    Highlights: → Welding processes are used to reconstitute previously tested Charpy specimens. → Stud welding is preferred for a quick installation, almost immediately operational. → Friction welding produces better quality welds, but requires a development effort. - Abstract: Reconstitution techniques are often used to allow material from previously fractured Charpy-V specimens to be reused for additional experiments. This paper presents a comparative experimental study of various reconstitution techniques and evaluates the feasibility of these methods for future use in shielded cells. The following techniques were investigated: arc stud welding, 6.0 kW CO 2 continuous wave laser welding, 4.5 kW YAG continuous wave laser welding and friction welding. Subsize Charpy specimens were reconstituted using a 400 W YAG pulsed wave laser. The best result was obtained with arc stud welding; the resilience of the reconstituted specimens and the load-displacement curves agreed well with the reference specimens, and the temperature elevation caused by the welding process was limited to the vicinity of the weld. Good results were also obtained with friction welding; this process led to the best quality welds. Laser welding seems to have affected the central part of the specimens, thus leading to different resilience values and load-displacement curves.

  16. Resistor holder

    Broadhurst, John H.

    1989-01-01

    A resistor device for use with electrostatic particle accelerators includes a resistor element positioned within a tubular housing having a fixed end cap at one end thereof and a movable end cap at the other end thereof. The tubular housing, fixed end cap, and movable end cap serve as an electromagnetic field for the resistor element. Conductive disks engage opposite ends of the resistor element and concentrically position the resistor element within the tubular housing. Helical springs engage the conductive disks and the end caps to yieldably support the movable end caps and resistor element for yieldable axial movement relative to the tubular housing. An annular conducting ring is secured to the tubular housing and is spaced radially from the movable end cap and cooperates with the latter to define an annular spark gap.

  17. 42 CFR 60.43 - Limitation, suspension, or termination of the eligibility of a HEAL lender or holder.

    2010-10-01

    ... notice, sent by certified mail, specifying his or her intention to terminate the lender or holder's... that a HEAL lender fails to meet the statutory definition of an “eligible lender.” (d) This section...

  18. Closeout of JOYO-1 Specimen Fabrication Efforts

    ME Petrichek; JL Bump; RF Luther

    2005-01-01

    Fabrication was well under way for the JOYO biaxial creep and tensile specimens when the NR Space program was canceled. Tubes of FS-85, ASTAR-811C, and T-111 for biaxial creep specimens had been drawn at True Tube (Paso Robles, CA), while tubes of Mo-47.5 Re were being drawn at Rhenium Alloys (Cleveland, OH). The Mo-47.5 Re tubes are now approximately 95% complete. Their fabrication and the quantities produced will be documented at a later date. End cap material for FS-85, ASTAR-811C, and T-111 had been swaged at Pittsburgh Materials Technology, Inc. (PMTI) (Large, PA) and machined at Vangura (Clairton, PA). Cutting of tubes, pickling, annealing, and laser engraving were in process at PMTI. Several biaxial creep specimen sets of FS-85, ASTAR-811C, and T-111 had already been sent to Pacific Northwest National Laboratory (PNNL) for weld development. In addition, tensile specimens of FS-85, ASTAR-811C, T-111, and Mo-47.5 Re had been machined at Kin-Tech (North Huntington, PA). Actual machining of the other specimen types had not been initiated. Flowcharts 1-3 detail the major processing steps each piece of material has experienced. A more detailed description of processing will be provided in a separate document [B-MT(SRME)-51]. Table 1 lists the in-process materials and finished specimens. Also included are current metallurgical condition of these materials and specimens. The available chemical analyses for these alloys at various points in the process are provided in Table 2

  19. Insider patent holder licensing in an oligopoly market with different cost structures: Fixed-fee, royalty, and auction

    Ming-Chung Chang

    2010-01-01

    The issue of the optimal licensing contract in firms having different cost structures is studied when the innovator is a producing patent holder who has three alternative licensing strategies, namely, the fixed-fee, royalty rate, and auction strategies. We conclude that the auction licensing strategy is not the best strategy when the innovator is a producing patent holder. This finding differs from that of Kabiraj (2004) where the auction licensing method is the optimal licensing strategy whe...

  20. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  1. Sequencing historical specimens: successful preparation of small specimens with low amounts of degraded DNA.

    Sproul, John S; Maddison, David R

    2017-11-01

    Despite advances that allow DNA sequencing of old museum specimens, sequencing small-bodied, historical specimens can be challenging and unreliable as many contain only small amounts of fragmented DNA. Dependable methods to sequence such specimens are especially critical if the specimens are unique. We attempt to sequence small-bodied (3-6 mm) historical specimens (including nomenclatural types) of beetles that have been housed, dried, in museums for 58-159 years, and for which few or no suitable replacement specimens exist. To better understand ideal approaches of sample preparation and produce preparation guidelines, we compared different library preparation protocols using low amounts of input DNA (1-10 ng). We also explored low-cost optimizations designed to improve library preparation efficiency and sequencing success of historical specimens with minimal DNA, such as enzymatic repair of DNA. We report successful sample preparation and sequencing for all historical specimens despite our low-input DNA approach. We provide a list of guidelines related to DNA repair, bead handling, reducing adapter dimers and library amplification. We present these guidelines to facilitate more economical use of valuable DNA and enable more consistent results in projects that aim to sequence challenging, irreplaceable historical specimens. © 2017 John Wiley & Sons Ltd.

  2. Evaluation of the effect of a laparoscopic robotized needle holder on ergonomics and skills.

    Bensignor, Thierry; Morel, Guillaume; Reversat, David; Fuks, David; Gayet, Brice

    2016-02-01

    Laparoscopy generates technical and ergonomics difficulties due to limited degrees of freedom (DOF) of forceps. To reduce this limitation, a new 5-mm robotized needle holder with two intracorporeal DOF, Jaimy(®), has been developed. The aim of this study was to evaluate its effects on ergonomics and skills. Fourteen surgeons including eight senior and six residents were crossover randomized and stratified based on experience. Three suturing tasks were performed with both Jaimy(®) and a classic needle holder (NH): task 1: Peg-Board; task 2: hexagonal suture; task 3: frontal suture. Postural ergonomics of the dominant arm were evaluated with an ergonomics score (RULA score) thanks to motion capture, and muscular ergonomics with electromyography of six muscular groups (flexor and extensor carpis, biceps, triceps, deltoid, trapeze). Performance outcomes are a quantitative and qualitative score, and skills outcomes are the measurement of the number of movements and the path length travelled by the instrument. The RULA score showed a statistically improved posture with Jaimy(®) (p < 0.001). The cumulative muscular workload (CMW) of four muscles was not different. However, the CMW was in favor of the NH for the flexor carpi ulnaris (p < 0.001) and the triceps (p = 0.027). The number of movements was not different (p = 0.39) although the path length was shorter with Jaimy(®) (p = 0.012). The score for task 1 was in favor of the NH (p = 0.006) with a higher quantity score. Task 2 score was not different (p = 0.086): The quality part of the score was in favor of Jaimy(®) (p = 0.009) and the quantity part was higher with the NH (p = 0.04). The score for task 3 was higher with Jaimy(®) (p = 0.001). This study suggests that the use of a robotized needle holder improves both posture and the quality of laparoscopic sutures.

  3. Effect of Holder pasteurization and frozen storage on macronutrients and energy content of breast milk.

    García-Lara, Nadia Raquel; Vieco, Diana Escuder; De la Cruz-Bértolo, Javier; Lora-Pablos, David; Velasco, Noelia Ureta; Pallás-Alonso, Carmen Rosa

    2013-09-01

    The aim of this study was to explore the effect of Holder pasteurization and frozen storage at -20°C after pasteurization on fat, total nitrogen, lactose, and energy content of breast milk. Both procedures are routinely practiced in human milk banks. A total of 34 samples of frozen breast milk, donated by 28 women, were collected. Once thawed, an aliquot of each sample was analyzed before pasteurization; the remaining milk was pasteurized (Holder method) and split into 8 aliquots. One aliquot was analyzed after pasteurization and the remainder frozen at -20°C and analyzed 30, 60, 90, 120, and 180 days later. For every aliquot, fat, total nitrogen, lactose, and energy content were determined using the device human Milk Analyzer. We observed a significant reduction in fat (3.5%; -0.17 (-0.29; -0.04) g/dL) and energy content (2.8%; -2.03 (-3.60; -0.46) g/dL) after pasteurization. A significant decrease over time was observed for fat, lactose and energy content. No significant changes were observed for nitrogen content. Mean differences between day 0 postpasteurization and day 180 were -0.13 (-0.21; -0.06) g/dL for fat, -0.08 (-0.13; -0.03) g/dL for lactose, and -1.55 (-2.38; -0.71) kcal/dL for energy content. The relative decreases were 2.8%, 1.7%, and 2.2%, respectively. Overall (postpasteurization + frozen storage), a 6.2% and 5% decrease were observed for fat and energy, respectively. Holder pasteurization decreased fat and energy content of human milk. Frozen storage at -20°C of pasteurized milk significantly reduced fat, lactose, and energy content of human milk.

  4. Update of NIST half-life results corrected for ionization chamber source-holder instability.

    Unterweger, M P; Fitzgerald, R

    2014-05-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. © 2013 Published by Elsevier Ltd.

  5. Development technique for deep drawing without blank holder to produce circular cup of brass alloy

    Ali Hassan Saleh; Ammer Khalaf Ali

    2015-01-01

    Of this technique compared to the conventional deep drawing is that the circular cup can be carried out in single action press with limit In this paper a new mechanism for deep drawing was proposed to produce circular cup from thin plate without blank holder. In this technique the die assembly includes punch, die and die-punch. A 2D axisymmetric finite element model was built using DEFORM software. Effect of die geometry (half- cone angle) on maximum load, thickness distribution, strain distr...

  6. A large deviation principle in H\\"older norm for multiple fractional integrals

    Sanz-Solé, Marta; Torrecilla-Tarantino, Iván

    2007-01-01

    For a fractional Brownian motion $B^H$ with Hurst parameter $H\\in]{1/4},{1/2}[\\cup]{1/2},1[$, multiple indefinite integrals on a simplex are constructed and the regularity of their sample paths are studied. Then, it is proved that the family of probability laws of the processes obtained by replacing $B^H$ by $\\epsilon^{{1/2}} B^H$ satisfies a large deviation principle in H\\"older norm. The definition of the multiple integrals relies upon a representation of the fractional Brownian motion in t...

  7. Repositioning accuracy: Comparison of a noninvasive head holder with thermoplastic mask for fractionated radiotherapy and a case report

    Sweeney, Reinhart; Bale, Reto; Vogele, Michael; Nevinny-Stickel, Meinhart; Bluhm, Anja; Auer, Thomas; Hessenberger, Gerhart; Lukas, Peter

    1998-01-01

    Purpose: To compare accuracy, clinical feasibility, and subjective patient impression between a noninvasive head holder (Vogele Bale Hohner [VBH]; Wellhoefer Dosimetry, Schwarzenbruck, Germany) developed at the University of Innsbruck and the thermoplastic mask fixation system for use in fractionated external radiotherapy. We present a case report of an actual patient fixated in the VBH head holder during radiation therapy. Materials and Methods: The VBH head holder consists of an individualized vacuum dental cast connected to a head plate via two hydraulic arms allowing noninvasive, reproducible head fixation of even uncooperative patients. Accuracy was tested and compared with that of the thermoplastic mask using the Phillips EasyGuide navigation system on five volunteers. Specific external registration points served as landmarks and their positions were compared after each repositioning. System and operator inaccuracy were also taken into account. The times taken for production and repositioning of the respective fixation devices were compared, and subjective impressions were noted. Results: Mean VBH head holder repositioning accuracy was 1.02 mm while that of the thermoplastic mask was 3.05 mm. 69% of mask repositionings showed a deviation > 2 mm and 41% > 3 mm (as opposed to 8% and 1% respectively for the VBH head holder) Those points located farthest away from the respective plane of fixation showed the largest deviations. Both production and repositioning times were similar between the systems; depending upon the patient, the VBH head holder was generally better tolerated than the mask system. Conclusion: Due to its significantly better repositioning accuracy compared to that of the thermoplastic mask, the VBH head holder is especially suited for external radiation requiring precise repositioning due to critical tissues in immediate surrounding of the area to be irradiated

  8. Virus isolation: Specimen type and probable transmission

    First page Back Continue Last page Overview Graphics. Virus isolation: Specimen type and probable transmission. Over 500 CHIK virus isolations were made. 4 from male Ae. Aegypti (?TOT). 6 from CSF (neurological involvement). 1 from a 4-day old child (transplacental transmission.

  9. Some recent innovations in small specimen testing

    Odette, G.R.; He, M.; Gragg, D.; Klingensmith, D.; Lucas, G.E.

    2002-01-01

    New innovative small specimen test techniques are described. Finite element simulations show that combinations of cone indentation pile-up geometry and load-penetration depth relations can be used to determine both the yield stress and strain-hardening behavior of a material. Techniques for pre-cracking and testing sub-miniaturized fracture toughness bend bars, with dimensions of 1.65x1.65x9 mm 3 , or less, are described. The corresponding toughness-temperature curves have a very steep transition slope, primarily due to rapid loss of constraint, which has advantages in some experiments to characterize the effects of specified irradiation variables. As one example of using composite specimens, an approach to evaluating helium effects is proposed, involving diffusion bonding small wires of a 54 Fe-based ferritic-martensitic alloy to a surrounding fracture specimen composed of an elemental Fe-based alloy. Finally, we briefly outline some potential approaches to multipurpose specimens and test automation

  10. Rehydration of forensically important larval Diptera specimens.

    Sanford, Michelle R; Pechal, Jennifer L; Tomberlin, Jeffery K

    2011-01-01

    Established procedures for collecting and preserving evidence are essential for all forensic disciplines to be accepted in court and by the forensic community at large. Entomological evidence, such as Diptera larvae, are primarily preserved in ethanol, which can evaporate over time, resulting in the dehydration of specimens. In this study, methods used for rehydrating specimens were compared. The changes in larval specimens with respect to larval length and weight for three forensically important blow fly (Diptera: Calliphoridae) species in North America were quantified. Phormia regina (Meigen), Cochliomyia macellaria (F.), and Chrysomya rufifacies (Macquart) third-instar larvae were collected from various decomposing animals and preserved with three preservation methods (80% ethanol, 70% isopropyl alcohol, and hot-water kill then 80% ethanol). Preservative solutions were allowed to evaporate. Rehydration was attempted with either of the following: 80% ethanol, commercial trisodium phosphate substitute solution, or 0.5% trisodium phosphate solution. All three methods partially restored weight and length of specimens recorded before preservation. Analysis of variance results indicated that effects of preservation, rehydration treatment, and collection animal were different in each species. The interaction between preservative method and rehydration treatment had a significant effect on both P. regina and C. macellaria larval length and weight. In addition, there was a significant interaction effect of collection animal on larval C. macellaria measurements. No significant effect was observed in C. rufifacies larval length or weight among the preservatives or treatments. These methods could be used to establish a standard operating procedure for dealing with dehydrated larval specimens in forensic investigations.

  11. Simultaneous specimen and stage cleaning device for analytical electron microscope

    Zaluzec, Nestor J.

    1996-01-01

    An improved method and apparatus are provided for cleaning both a specimen stage, a specimen and an interior of an analytical electron microscope (AEM). The apparatus for cleaning a specimen stage and specimen comprising a plasma chamber for containing a gas plasma and an air lock coupled to the plasma chamber for permitting passage of the specimen stage and specimen into the plasma chamber and maintaining an airtight chamber. The specimen stage and specimen are subjected to a reactive plasma gas that is either DC or RF excited. The apparatus can be mounted on the analytical electron microscope (AEM) for cleaning the interior of the microscope.

  12. Evaluation of the maxillary premolar roots dissociation using radiographic holders with conventional and digital radiography

    Marcia Regina Ramalho da Silva Bardauil

    2010-09-01

    Full Text Available This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP, and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA and digital radiography (Kodak RVG 6100, Kodak, Rochester, USA. The study sample was comprised of 20 patients with a total of 20 maxillary premolars that were radiographed, using the paralleling angle technique (GP, with a 20º variation of the horizontal angle (GM and 25º variation of the horizontal angle combined with 15º vertical angle (GMV. Each image was independently analyzed by two experienced examiners. These examiners assigned a score to the diagnostic capability of root dissociation and the measurement of the distance between the apexes. Statistical data was derived using the Wilcoxon Signed Rank test, Friedman and T test. The means of the measured distances between buccal and lingual root apexes were greater for the GMV, which ranged from 2.3 mm to 3.3 mm. A statistically significant difference was found between GM and GMV when compared to GP with p < 0.01. An established best diagnostic dissociation roots image was found in the GMV. These results support the use of the anterior X-ray holders which offer a better combined deviation (GMV to dissociate maxillary premolar roots in both radiography systems.

  13. Custom Fit 3D-Printed Brain Holders for Comparison of Histology with MRI in Marmosets

    Guy, Joseph R.; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C.; Reich, Daniel S.

    2015-01-01

    Background MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. New Method 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. Results The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Comparison with Existing Methods Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. Conclusions The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. PMID:26365332

  14. Raising awareness about protection and control of nuclear materials held by 'small-scale holders'

    Ladsous, D.; Coulie, E.; Giorgio, M.

    2013-01-01

    In France, the activities carried out by the 'small-scale holders' of nuclear materials are organized by a specific regulatory system which defines in a detailed way their obligations and the means of control of the government. The first part of the article presents the legal framework relating to the use of nuclear materials by small-scale holders in civilian fields. The importance of the declaration of the nuclear material inventory is clearly emphasized and must be prepared and transmitted to the Institute for Radiological Protection and Nuclear Safety (IRSN) every year. The second part describes how this declaration is used to provide basic information for the competent Ministry and the inspectors to check the correct application of the regulatory requirements relating to physical protection and to the control of nuclear materials. Finally, the last part presents the on-site inspections carried out by sworn and accredited inspectors under the authority of the competent Authority, which provide an overall picture and allow an evaluation of the risks of theft, loss or diversion of these materials. (authors)

  15. Effect of Holder pasteurization on macronutrients and immunoglobulin profile of pooled donor human milk.

    Adhisivam, B; Vishnu Bhat, B; Rao, Krishna; Kingsley, S M; Plakkal, Nishad; Palanivel, C

    2018-03-27

    The objective of this study was to study the effect of Holder pasteurization on macronutrients and immunoglobulin profile of pooled donor human milk. This descriptive study was conducted in a Human Milk Bank of a tertiary care teaching institute in south India. Thirty random paired pooled donor human milk samples (before and after pasteurization) were analyzed for macronutrients (protein, fat, carbohydrates) using infrared spectroscopy. Similarly, immunoglobulin profile (IgA and IgG) before and after pasteurization was quantified using ELISA. The mean values of protein, fat, and carbohydrates in pooled donor milk pre-pasteurization were 1.6, 3.6, and 6.1 g/dl compared with post-pasteurization values 1.4, 2.7, and 5.9 g/dl, respectively. Pasteurization reduced protein, fat, and energy content of pooled donor milk by 12.5%, 25%, and 16%, respectively. However, carbohydrates were not significantly reduced. Pasteurization decreased IgA by 30% and IgG by 60%. Holder pasteurization of pooled donor human milk decreases protein, fat, and energy content and also reduces the levels of IgA and IgG.

  16. Choosing health: qualitative evidence from the experiences of personal health budget holders.

    Davidson, Jacqueline; Baxter, Kate; Glendinning, Caroline; Irvine, Annie

    2013-10-01

    Personal health budgets were piloted in the English National Health Service between 2009 and 2012. Semi-structured interviews with a sub-sample of early budget holders aimed to explore their experiences of receiving and using a budget. Over 2000 people from 20 pilot sites were recruited to a multi-method evaluation of the personal health budget pilots. A sub-sample of 58 people was selected for qualitative interviews three months after the offer of a budget; 52 were re-interviewed six months later. The purposively selected sample reflected a range of health conditions, locality, age and gender. Personal health budgets were reported to have positive impacts on health, health care and relatives/family. Benefits often extended beyond the condition for which the budget had been awarded. However, interviewees rarely knew the level of their budget; some reported difficulty in agreeing acceptable uses for their budget; and delays could occur in procuring chosen services or equipment. Patients' experiences offer valuable insights for the roll-out of personal health budgets beyond the pilot phase. Flexibility in how budgets are used may allow maximum benefits to be derived. Clear information about what budgets can and cannot be used for, with suggestions offered, will be useful. People with newly diagnosed or recent sudden onset conditions may need more help to plan their support, but all budget holders are likely to benefit from regular contact with staff for reassurance and continued motivation.

  17. Running Mechanics and Metabolic Responses with Water Bottles and Bottle Belt Holders.

    Vincent, Heather K; Zdziarski, Laura A; Fallgatter, Kyle; Negron, Giorgio; Chen, Cong; Leavitt, Trevor; Horodyski, MaryBeth; Wasser, Joseph G; Vincent, Kevin R

    2018-01-18

    This study determined whether differential kinematics, kinetics, rates of energy use and cardiopulmonary responses occurred during running with water bottles and bottle belt holders compared to running only. Trained runners (N=42; 27.2±6.4 yr) ran on an instrumented treadmill for four conditions in a randomized order: 1) control run (CON); 2) hand-held full water bottle (FULL, 16.9 fluid oz; 454 g); 3) hand-held half-full water bottle (HALF, 8.4 fluid oz.; 227 g); and 4) waist-worn bottle belt holder (BELT; hydration belt; 676 g). Gas exchange was measured using a portable gas analyzer. Kinetic and kinematic responses were determined via standard 3D videographic techniques. Interactions of limb side (right, left) by study condition (CON, FULL, HALF, BELT) were tested for rates of oxygen use and energy expenditure, and kinematic and kinetic parameters. No significant limb side × condition interactions existed for rates of oxygen use or energy expenditure. A significant interaction occurred with sagittal elbow flexion (pwater by hand or on the waist does not significantly change kinematics of running motion, rates of oxygen use and energy expenditure or cardiopulmonary measures over short durations. Runners are likely making adjustments to joint moments and powers that preserve balance and protect the lower extremity joints while maintaining the rates of oxygen use and energy expenditure.

  18. Effects of Holder pasteurization on the protein profile of human milk.

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Cavaletto, Maria; Spertino, Stefano; Icardi, Sara; Tortone, Claudia; Visser, Gerard H A; Gazzolo, Diego

    2016-04-07

    The most widespread method for the treatment of donor milk is the Holder pasteurization (HoP). The available literature data show that HoP may cause degradation of some bioactive components. The aim of this study was to determine the effect of HoP on the protein profile of human milk (HM) using a GeLC-MS method, a proteomic approach and a promising technique able to offer a qualitative HM protein profile. HM samples were collected by standardized methods from 20 mothers carrying both preterm and term newborns. A aliquot of each sample was immediately frozen at -80 °C, whilst another one was Holder pasteurized and then frozen. All samples were then analyzed by GeLC-MS. The protein bands of interest were excised from the gel, digested with trypsin and identified by nano-HPLC-MS/MS analysis. The protein profile before and after HoP showed qualitative differences only in 6 samples out of 20, while in the remaining 14 no detectable differences were found. The differences interested only colostrums and transitional milk samples and regarded the decrease of the electrophoretic bands corresponding to alpha and beta-casein, tenascin, lactoferrin and immunoglobulin. In the majority of samples, HoP did not cause any modification, thereby preserving the biological activity of HM proteins.

  19. Impact of the Flame-Holder Heat-Transfer Characteristics on the Onset of Combustion Instability

    Hong, Seunghyuck

    2013-10-03

    In this article, we investigate the impact of heat transfer between the flame and the flameholder on the dynamic stability characteristics of a 50-kW backward-facing step combustor. We conducted a series of tests where two backward step blocks were used, made of ceramic and stainless steel, whose thermal conductivities are 1.06 and 12 W/m/K, respectively. Stability characteristics of the two flame-holder materials were examined using measurements of the dynamic pressure and flame chemiluminescence over a range of operating conditions. Results show that with the ceramic flameholder, the onset of instability is significantly delayed in time and, for certain operating conditions, disappears altogether, whereas with the higher conductivity material, the combustor becomes increasingly unstable over a range of operating conditions. We explain these trends using the heat flux through the flameholder and the change in the burning velocity near the step wall. Results suggest a potential approach using low-thermal-conductivity material near the flame-holder as passive dynamics suppression methods. Copyright © Taylor & Francis Group, LLC.

  20. Volatile Constituents, Inorganic Elements and Primary Screening of Bioactivity of Black Coral Cigarette Holders

    Ganggang Shi

    2011-05-01

    Full Text Available Black corals (BC have been used for a long time in Chinese medicine, and may have some pharmaceutical functions when used as material for cigarette holders in southeast China. This study is aimed to investigate the bioactivities of volatile constituents in BC and to explore the folklore behind the use of BC cigarette holders (BCCHs. We extracted the volatile constituents of BC by supercritical fluid extraction (SFE with carbon dioxide (CO2-SFE, then identified and analyzed the constituents by gas chromatography-mass spectrometry (GC-MS. In total, 15 components were reliably identified in BC and found to be biologically active. These included triethyl phosphate, butylated hydroxytoluene, cedrol, n-hexadecanoic acid, squalene, and cholesterol. Meanwhile 13 inorganic elements (P, Ca, Mg, S, B, Si, Fe, Cu, Zn, Ba, etc. were determined by inductively coupled plasma spectrometer (ICPS. In the bioactivity tests, the BC extract (BCE showed a scavenging activity of 2,2-diphenyl-1-picrylhydrazyl free radicals and hydroxyl radicals by phenanthroline-Fe (II oxidation and moderate inhibition of Gram-positive microorganisms. The antioxidant and antimicrobial activities of BC, which are related to the active chemical composition, may explain the perceived benefit for cigarette smokers who use BCCHs.

  1. Custom fit 3D-printed brain holders for comparison of histology with MRI in marmosets.

    Guy, Joseph R; Sati, Pascal; Leibovitch, Emily; Jacobson, Steven; Silva, Afonso C; Reich, Daniel S

    2016-01-15

    MRI has the advantage of sampling large areas of tissue and locating areas of interest in 3D space in both living and ex vivo systems, whereas histology has the ability to examine thin slices of ex vivo tissue with high detail and specificity. Although both are valuable tools, it is currently difficult to make high-precision comparisons between MRI and histology due to large differences inherent to the techniques. A method combining the advantages would be an asset to understanding the pathological correlates of MRI. 3D-printed brain holders were used to maintain marmoset brains in the same orientation during acquisition of ex vivo MRI and pathologic cutting of the tissue. The results of maintaining this same orientation show that sub-millimeter, discrete neuropathological features in marmoset brain consistently share size, shape, and location between histology and ex vivo MRI, which facilitates comparison with serial imaging acquired in vivo. Existing methods use computational approaches sensitive to data input in order to warp histologic images to match large-scale features on MRI, but the new method requires no warping of images, due to a preregistration accomplished in the technique, and is insensitive to data formatting and artifacts in both MRI and histology. The simple method of using 3D-printed brain holders to match brain orientation during pathologic sectioning and MRI acquisition enables rapid and precise comparison of small features seen on MRI to their underlying histology. Published by Elsevier B.V.

  2. Social Perception of Hydrogen Technologies: The View of Spanish Stake holders

    Ferri Anglada, S.

    2013-01-01

    This technical report presents an overview of the social perception and vision of a sample of Spanish stake holders on hydrogen technologies. The study is based on the implementation of a survey, combining both quantitative and qualitative data. An ad hoc electronic survey was design to collect views and perceptions on several key factors regarding this innovative energy alternative. The group of experts participating (N=130) in the study, comes mainly from research centers, universities and private companies. The survey addresses three major themes: expert views, social acceptability, and contextual factors of hydrogen technologies. The aim is to capture both the current and the future scene as viewed by the experts on hydrogen technologies, identifying key factors in terms of changes, uncertainties, obstacles and opportunities. The objective is to identify potential key features for the introduction, development, promotion, implementation, and large-scale deployment of a highly successful energy proposal in countries such as Iceland, one of the pioneers in base its economy on hydrogen technologies. To conclude, this report illustrates the positive engagement of a sample of Spanish stake holders towards hydrogen technologies that may prove vital in the transition towards the Hydrogen Economy in Spain. (Author)

  3. Material selection for the tool holder working under hard milling conditions using different multi criteria decision making methods

    Çalışkan, Halil; Kurşuncu, Bilal; Kurbanoğlu, Cahit; Güven, Şevki Yılmaz

    2013-01-01

    Highlights: ► The material selection problem for tool holders used in hard milling was solved. ► EXPROM2, TOPSIS and VIKOR methods were used for ranking the alternative materials. ► The weighting of criteria was performed by compromised weighting method. ► The best material for the tool holder was selected as Fe–5Cr–Mo–V aircraft steel. -- Abstract: Nowadays machining of materials in their hardened state, also called hard machining, is a challenge in production of tools and molds. It has some advantages such as lower process time and lower manufacturing cost when compared to conventional machining. In machining of hard workpiece materials, however, very high stresses act on the tool holder through the cutting tool. These stresses necessitate the tool holder to have some specific properties. Especially in hard milling, the tool holder should have high stiffness and should be able to dissipate the energy generated during interrupted cutting. Material cost of the tool holder is also important since lower costs provide a competitive advantage for manufacturers. The material selection for the tool holder should be conducted considering aforementioned requirements. To tackle the difficulty of the material selection with specific properties from a large number of alternatives, multi-criteria decision-making (MCDM) methods have been used. In this paper a decision model including extended PROMETHEE II (EXPROM2) (preference ranking organization method for enrichment evaluation), TOPSIS (technique for order performance by similarity to ideal solution) and VIKOR (VIšekriterijumsko KOmpromisno Rangiranje) methods were used for the selection of the best material for the tool holder used in hard milling. The criteria weighting was performed by compromised weighting method composed of AHP (analytic hierarchy process) and Entropy methods. The candidate materials were ranked by using these methods and the results obtained by each method were compared. It was confirmed

  4. A Study on consensus development through stake holder engagement for the use of nuclear energy in Japan

    Aoyama, Yoshiko; Sawada, Tetsuo; Fujii, Yasuhiko

    2008-01-01

    In order to alleviate the distrust surrounding the use of nuclear energy and operation of nuclear facilities, as well as to foster trust and find better ways to live in harmony with society, it is essential for the state and electric power utilities not to provide one-sided information, but to formulate adequate bilateral communication and dialogue with stake holders. In this study, we conducted a case study focused on four stake holder meetings with a view to ensuring safety in the use of nuclear energy and operation of nuclear facilities in Japan; the 'Community Meeting for Securing the Transparency of Kashiwazaki-Kariwa Nuclear Power Station (Chiiki-no-kai)'; the 'Monitoring and Evaluation Conference on Environmental Radiation', established by communities where nuclear facilities are installed; the 'Round-Table Conference on Nuclear Power Policy' and the 'Conference for Public Participation and Decision Making for Nuclear Energy Policy' organized by Japan Atomic Energy Commission. As a consequence, it has been observed that in each case varying opinions were summarized through stake holder meetings, but the fact that no system exists to reflect these opinions in design of the nuclear energy policy has emerged as a controversial point. This study suggests future efforts in regard to the requirements in Japan for stake holder meetings that are necessary for fostering trust and mutual understanding among stake holders including the state and local government, electric power utilities and local residents. (author)

  5. Warm Deep Drawing of Rectangular Parts of AZ31 Magnesium Alloy Sheet Adopting Variable Blank Holder Force

    Peng Yinghong; Chang Qunfeng; Li Dayong; Zeng Xiaoqin

    2007-01-01

    AZ31 magnesium alloy sheet with good shape and formability is fabricated by warm cross rolling. Uniaxial tensile tests are conducted using a Gleeble 3500 thermal - mechanical simulator, and the mechanical properties of AZ31 magnesium alloy sheet are analyzed. A warm deep drawing process of square part is also simulated by the finite element method. The influences of blank holder force on the formability are numerically investigated. A double-action hydraulic press that can realize adjustable blank holder forces is developed and its working principle and control system are introduced. Some warm deep drawing experiments of square parts of AZ31 magnesium alloy sheet are also performed. Different variation schemes of the blank holder force with the stroke of the punch are tested, and the experiment results are compared. Results show that the suitable blank holder force variation scheme is a ladder curve with the punch stroke. Adopting the variable blank holder force technique can improve 13.2% of the drawing depth of square parts of AZ31 magnesium alloy sheet

  6. Standard guide for preparation of metallographic specimens

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 The primary objective of metallographic examinations is to reveal the constituents and structure of metals and their alloys by means of a light optical or scanning electron microscope. In special cases, the objective of the examination may require the development of less detail than in other cases but, under nearly all conditions, the proper selection and preparation of the specimen is of major importance. Because of the diversity in available equipment and the wide variety of problems encountered, the following text presents for the guidance of the metallographer only those practices which experience has shown are generally satisfactory; it cannot and does not describe the variations in technique required to solve individual specimen preparation problems. Note 1—For a more extensive description of various metallographic techniques, refer to Samuels, L. E., Metallographic Polishing by Mechanical Methods, American Society for Metals (ASM) Metals Park, OH, 3rd Ed., 1982; Petzow, G., Metallographic Etchin...

  7. Natural History Specimen Digitization: Challenges and Concerns

    Ana Vollmar

    2010-10-01

    Full Text Available A survey on the challenges and concerns invovled with digitizing natural history specimens was circulated to curators, collections managers, and administrators in the natural history community in the Spring of 2009, with over 200 responses received. The overwhelming barrier to digitizing collections was a lack of funding, based on a limited number of sources, leaving institutions mostly responsible for providing the necessary support. The uneven digitization landscape leads to a patchy accumulation of records at varying qualities, and based on different priorities, ulitimately influencing the data's fitness for use. The survey also found that although the kind of specimens found in collections and their storage can be quite varible, there are many similar challenges when digitizing including imaging, automated text scanning and parsing, geo-referencing, etc. Thus, better communication between domains could foster knowledge on digitization leading to efficiencies that could be disseminated through documentation of best practices and training.

  8. Thermal endurance tests on silicone rubber specimens

    Warburton, C.

    1977-07-01

    Thermal endurance tests have been performed on a range of silicone rubber specimens at temperature above 300 0 C. It is suggested that the rubber mix A2426, the compound from which Wylfa sealing rings are manufactured, will fail at temperatures above 300 0 C within weeks. Hardness measurements show that this particular rubber performs in a similar manner to Walker's S.I.L./60. (author)

  9. The working procedure of human autopsy specimens

    Chen Rusong; Liu Guodong

    2000-01-01

    In order to perform the Coordinated Research Program for the Reference Asian Man (phase 2): Ingestion and body content of trace elements of importance in Radiation Protection, study on elemental content in organs of normal Chinese has been worked by China Institute for Radiation Protection and Institute of Radiation Medicine - CAMS in recent two years. Sampling and sample collection of human tissues and the procedures of sample preparation of human autopsy specimens are enlisted

  10. Bireflectance imaging of coal and carbon specimens

    Crelling, J.C. [Department of Geology, 1259 Lincoln Drive, Southern Illinois University, Carbondale, Illinois 62901 (United States); Glasspool, I.J.; Gibbins, J.R.; Seitz, M. [Department of Mechanical Engineering, Imperial College, Exhibition Road, London, SW7 2BX (United Kingdom)

    2005-11-10

    Although bireflectance measurements are routine, to date they have been limited to selected single point measurements. This study uses a 360{sup o} rotating polarizer in the incident light path combined with digital imaging to map the optical bireflectance of a polished specimen over the complete field of view, a system herein referred to as 'Bireflectance Imaging of Coal and Carbon Specimens' (BRICCS). True maximum reflectance maps and maps of polarizer angle for maximum reflectance (to identify co-ordered regions) are obtainable from the same data. A variety of coal, coke, char, graphite, and carbon/carbon specimens have been examined with the BRICCS system and the results demonstrate that the system can produce accurate maximum and apparent minimum reflectance, bireflectance, and extinction angle images. For example, flakes of natural graphite show no bireflectance along their long axis except in areas that have been strained. The images are maps showing the value of every pixel that has been calibrated by mineral reflectance standards. The maps are unique in that they show fields of view that cannot be seen by normal viewing through the microscope. For example, the bireflectance maps show the maximum difference between the maximum and apparent minimum reflectance for each of the million pixels at twenty orientations of the polarizer. (author)

  11. Investigation of holder pressure and size effects in micro deep drawing of rectangular work pieces driven by piezoelectric actuator.

    Aminzahed, Iman; Mashhadi, Mahmoud Mosavi; Sereshk, Mohammad Reza Vaziri

    2017-02-01

    Micro forming is a manufacturing process to fabricate micro parts with high quality and a cost effective manner. Deep drawing could be a favorable method for production of complicated parts in macro and micro sizes. In this paper piezoelectric actuator is used as a novel approach in the field of micro manufacturing. Also, in current work, investigations are conducted with four rectangular punches and blanks with various thicknesses. Blank holder pressure effects on thickness distributions, punch force, and springback are studied. According to the results of this work, increasing of blank holder pressure in scaled deep drawing, in contrast to thickness of drawn part, leads to decrease in the punch forces and springback. Furthermore, it is shown that in micro deep drawing, the effects of holder pressure on mentioned parameters can be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. HMSRP Hawaiian Monk Seal Specimen Data (includes physical specimens, collection information, status, storage locations, and laboratory results associated with individual specimens)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set includes physical specimens, paper logs and Freezerworks database of all logged information on specimens collected from Hawaiian monk seals since 1975....

  13. 15N tracer technique for studying efficiency of deep placed fertilizer through nutriseed holder in direct seeded rice

    Asha, V.S.; Arulmozhiselvan, K.

    2006-01-01

    In order to estimate N use efficiency in deep placement of NPK straight fertilizers, two pot experiments were conducted in high clay soil with direct seeded rice. 15 N urea was used as a tracer. A newly designed 'Nutriseed Holder' was used for simultaneous deep placement of fertilizers and sowing of seeds. Each holder had two cavities, one on top for holding seed and another one at bottom for holding fertilizer material. By implanting a holder in puddled soil, a rice hill was established. The length (5 or 10 cm) and width (8 or 12 mm) of nutriseed holder was standardized while evaluating the effect of Azolla, neem and seed inoculants. Appreciably, deep placement of plain NPK fertilizer in 12 mm holder placed at 5 cm depth recorded the highest grain yield with a yield increase of 81.8 per cent during rabi 2002 (cv CO 43) and 84.8 per cent during summer 2003 (cv CO 47) over broadcast application. Further, it increased recovery of added JSN in grain + straw to the tune of 57.1 per cent in rabi and 54.7 per cent in summer as compared to broadcast application (26.1% in rabi, 34.2 in summer). Deep placement enhanced more retention in soil (up to 9.0% in rabi, 14.6% in summer) whereas broadcast application enhanced more retention in Azolla biomass that was grown in floodwater (up to 2.3 % in rabi, 4.3 % in summer). Use of 12 mm width nutriseed holder aiding deep placement at 5 cm depth was found suitable for deriving high yield and N use efficiency. (author)

  14. Use of globally unique identifiers (GUIDs) to link herbarium specimen records to physical specimens.

    Nelson, Gil; Sweeney, Patrick; Gilbert, Edward

    2018-02-01

    With the advent of the U.S. National Science Foundation's Advancing Digitization of Biodiversity Collections program and related worldwide digitization initiatives, the rate of herbarium specimen digitization in the United States has expanded exponentially. As the number of electronic herbarium records proliferates, the importance of linking these records to the physical specimens they represent as well as to related records from other sources will intensify. Although a rich and diverse literature has developed over the past decade that addresses the use of specimen identifiers for facilitating linking across the internet, few implementable guidelines or recommended practices for herbaria have been advanced. Here we review this literature with the express purpose of distilling a specific set of recommendations especially tailored to herbarium specimen digitization, curation, and management. We argue that associating globally unique identifiers (GUIDs) with physical herbarium specimens and including these identifiers in all electronic records about those specimens is essential to effective digital data curation. We also address practical applications for ensuring these associations.

  15. Development of fatigue life evaluation technique using miniature specimen

    Nogami, Shuhei; Nishimura, Arata; Fujiwara, Masaharu; Hisaka, Tomoaki

    2012-01-01

    To develop the fatigue life evaluation technique using miniature specimen, the investigation of the effect of specimen size and specimen shape on the fatigue life and the development of the fatigue testing machine, especially the extensometer, were carried out. The effect of specimen size on the fatigue life was almost negligible for the round-bar specimens. The shorter fatigue life at relatively low strain range conditions for the hourglass specimen that the standard specimen were observed. Therefore the miniature round-bar specimen was considered to be adequate for the fatigue life evaluation using small specimen. Several types of the extensometer system using a strain gauge and a laser has been developed for realizing the fatigue test of the miniature round-bar specimen at high temperature in vacuum. (author)

  16. A new sample holder for laser-excited pump-probe magnetic measurements on a Focus photoelectron emission microscope

    Miguel, Jorge; Bernien, Matthias; Kuch, Wolfgang; Bayer, Daniela; Aeschlimann, Martin; Sanchez-Barriga, Jaime; Kronast, Florian; Duerr, Hermann A.

    2008-01-01

    A custom-made Omicron-compatible sample holder for time-resolved photoelectron emission microscopy experiments is presented. It comprises a sample plate with four contacts that hosts a chip carrier where the semiconductor substrate is mounted. Covering the sample holder, a 6 mm diameter mask protects electrostatically the sample from the extractor lens voltage while keeping the imaging quality unperturbed. The improvements are a greater sample lifetime and the ability to withstand much higher currents in the stripline that provides the magnetic pulse to the magnetic microstructure

  17. Update of NIST half-life results corrected for ionization chamber source-holder instability

    Unterweger, M.P.; Fitzgerald, R.

    2014-01-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties. - Highlights: • The NIST half-life data is corrected for sample positioning variations and refitted. • These results are reported and increased errors in the reported values are given. • Longer lived radionuclides are discussed

  18. Measured Thermal and Fast Neutron Fluence Rates for ATF-1 Holders During ATR Cycle 157D

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 157D which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution.

  19. Monosyllabic Place Holders in Child Acquisition of Spanish as a Second Language

    Estrella Nicolás

    2018-03-01

    Full Text Available Monosyllabic place holders (MPHs have been studied extensively in first-language (L1 acquisition of Spanish and other Romance languages. However, the study of MPHs in second-language (L2 acquisition, both by children and adults, has received much less attention. This study provides evidence for the presence of MPHs in the L2 Spanish of two L1 Moroccan Arabic children living in Spain. The age difference between the children (10;9 for Rachida and 6;10 for Khalid allows us to address the issue of whether the younger child would use MPHs, as is the case in L1 acquisition. However, what the data show is that both children used MPHs, although Khalid’s MPH rate was slightly higher than Rachida’s. Therefore, based on these findings we argue that MPHs can constitute a strategy available for all child learners of Spanish.

  20. Moving Object Detection Using Scanning Camera on a High-Precision Intelligent Holder

    Chen, Shuoyang; Xu, Tingfa; Li, Daqun; Zhang, Jizhou; Jiang, Shenwang

    2016-01-01

    During the process of moving object detection in an intelligent visual surveillance system, a scenario with complex background is sure to appear. The traditional methods, such as “frame difference” and “optical flow”, may not able to deal with the problem very well. In such scenarios, we use a modified algorithm to do the background modeling work. In this paper, we use edge detection to get an edge difference image just to enhance the ability of resistance illumination variation. Then we use a “multi-block temporal-analyzing LBP (Local Binary Pattern)” algorithm to do the segmentation. In the end, a connected component is used to locate the object. We also produce a hardware platform, the core of which consists of the DSP (Digital Signal Processor) and FPGA (Field Programmable Gate Array) platforms and the high-precision intelligent holder. PMID:27775671

  1. Moving Object Detection Using Scanning Camera on a High-Precision Intelligent Holder

    Shuoyang Chen

    2016-10-01

    Full Text Available During the process of moving object detection in an intelligent visual surveillance system, a scenario with complex background is sure to appear. The traditional methods, such as “frame difference” and “optical flow”, may not able to deal with the problem very well. In such scenarios, we use a modified algorithm to do the background modeling work. In this paper, we use edge detection to get an edge difference image just to enhance the ability of resistance illumination variation. Then we use a “multi-block temporal-analyzing LBP (Local Binary Pattern” algorithm to do the segmentation. In the end, a connected component is used to locate the object. We also produce a hardware platform, the core of which consists of the DSP (Digital Signal Processor and FPGA (Field Programmable Gate Array platforms and the high-precision intelligent holder.

  2. The role of stake holders in the Italian debate on the national radioactive waste deposit

    Cantone, Marie C.

    2008-01-01

    Full text: In early 2003, following an increased concern about the international terrorist threat, the Italian Government declared an emergency status for national nuclear installations, and in particular for radioactive waste deposits. A working group of experts - mainly from the Society for the Management of Nuclear Installations (SOGIN) and the Agency for New Technologies, Energy and Environment (ENEA) - was appointed and charged with the analysis of the technical aspects implied in the creation of a repository to host permanently LLRW and MLRW as well as to host temporarily HLRW. In November 2003 the Italian Government passed a decree to authorize the creation of a national nuclear waste repository within a geological salt deposit in the territory of Scanzano Jonico, in the Basilicata Region. The decision was made without any negotiation with the local population and the authorities of Scanzano Jonico. The lack of transparent communication and the attempt to impose the project 'from the top' was perceived as a 'deceptive strategy'. The population of the entire region spontaneously organized a mass protest movement against the project; blockades were carried out on the major highway connecting Northern to Southern Italy and the controversy gained the attention of the national mass media. Two weeks later, the Italian government withdrew the decree. Presently, the Italian nuclear waste is distributed over more than 20 locations in 11 different Regions, and the creation of a national disposal site has been postponed. The present study aims at highlighting the reasons behind social conflicts on nuclear waste risks. We will examine the attitudes and the communication strategies of the different stake holders which took part in the public debate on the Italian nuclear waste dump. Drawing on methodologies used in media studies, we are carrying out a quantitative and qualitative analysis of the main national and local newspapers in order to draw a 'map' of the

  3. Holder continuity of bounded weak solutions to generalized parabolic p-Laplacian equations II: singular case

    Sukjung Hwang

    2015-11-01

    Full Text Available Here we generalize quasilinear parabolic p-Laplacian type equations to obtain the prototype equation $$ u_t - \\hbox{div} \\Big(\\frac{g(|Du|}{|Du|} Du\\Big = 0, $$ where g is a nonnegative, increasing, and continuous function trapped in between two power functions $|Du|^{g_0 -1}$ and $|Du|^{g_1 -1}$ with $1Holder continuous with some degree of commonality between degenerate and singular types. By using geometric characters, our proof does not rely on any of alternatives which is based on the size of solutions.

  4. Safeguards-relevant information collection from small holders – experiences and challenges

    Sundén, Erika; Dufva, Martina; Dahlberg, Joakim

    2015-01-01

    A number of universities, research institutions, hospitals, and other businesses are in possession of relatively small amounts of nuclear material. In some cases the material is in activities related to the nuclear fuel cycle, but there is also a wide variety of other applications. Regardless of application, material accountancy must be reported to the European Commission (EC) and, in Sweden, to the Swedish Radiation Safety Authority (SSM). However, checking the completeness and correctness of the reports from operators with very small amounts of nuclear material can easily be forgotten or viewed as being less important. Starting in the beginning of 2013 SSM increased its effort in this area and began working more actively gathering information and checking its correctness. Informing the operators in possession of nuclear material of the rules and regulations is a major part of this work, as it has been noted that the knowledge level of safeguarding nuclear material in many locations is very low. This paper will give a description of the work being performed by SSM to ensure that information related to the possession of nuclear material are gathered and correctly declared. It will give an overview of the different procedures that are applied to different categories of small holders in Sweden (where the differences are mostly due to historical reasons). It will also entail some of the challenges met along the way; such as explaining to radiographers that for nuclear non-proliferation purposes it is the shielding uranium container which is of interest, not the isotope emitting the radiation. What we have experienced being the major differences between collecting information from small holders as compared to larger nuclear facilities will also be outlined. The paper ends with an outline for future work.

  5. The Effect of Holder Pasteurization on Activin A Levels in Human Milk.

    Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Barbagallo, Ignazio; Visser, Gerard H A; Gazzolo, Diego

    2016-11-01

    There is evidence that mother's own milk is the best nutrient in terms of multiorgan protection and infection prevention. However, when maternal milk is scarce, the solution can be represented by donor milk (DM), which requires specific storage procedures such as Holder Pasteurization (HoP). HoP is not free from side effects since it is widely known that it causes qualitative/quantitative changes in milk composition, particularly in the protein content. Therefore, the aim of this study is to investigate the effects of HoP on Activin A, a neurobiomarker known to play an important role in the development and protection of the central nervous system. In 24 mothers who delivered preterm (n = 12) and term (n = 12) healthy newborns, we conducted a pretest/test study where the milk donors acted as their own controls. Each sample was divided into two parts: the first was frozen at -80°C (Group 1); the second was Holder-pasteurized before freezing at -80°C (Group 2). Activin A was quantified using an ELISA test. Activin A was detected in all samples. There were no significant differences (p > 0.05) between the two groups, also when the analysis was stratified for gestational age at delivery and milk maturation degree (p > 0.05, for both). The present findings on the absence of any side effects of HoP on the milk concentration of Activin A offer additional support to the efficacy of HoP in DM storage. Our data open up to further investigations on neurobiomarkers' assessment in human milk and their preanalytical stability according to storage procedures.

  6. Histological evaluation of 400 cholecystectomy specimens

    H Kumar

    2015-09-01

    Full Text Available Background: A majority of gallbladder specimens show changes associated with chronic cholecystitis; however few harbour a highly lethal carcinoma. This study was conducted to review the significant histopathological findings encountered in gallbladder specimens received in our laboratory.Materials and Methods: Four hundred cholecystectomy specimens were studied over a period of five years (May, 2002 to April, 2007 received at department of pathology, Kasturba Medical College, Mangalore, India. Results: Gallstones and associated diseases were more common in women in the 4th to 5th decade as compared to men with M: F ratio of 1:1.33. Maximum number of patients (28.25% being 41 to 50 years old. Histopathologically, the most common diagnosis was chronic cholecystitis (66.75%, followed by chronic active cholecystitis (20.25%, acute cholecystitis (6%, gangrenous cholecystitis (2.25%,xanthogranulomatous cholecystitis (0.50%, empyema (1%, mucocele (0.25%, choledochal cyst (0.25%, adenocarcinoma gallbladder (1.25% and  normal  gallbladders (1%.Conclusion: All lesions were found more frequently in women except chronic active cholecystitis. Gallstones were present in (80.25% cases, and significantly associated with various lesions (P value 0.009. Pigment stones were most common, followed by cholesterol stones and mixed stones. Adequate  sectioning  is  mandatory  in  all  cases  to  assess  epithelial changes arising from cholelithiasis and chronic cholecystitis as it has been known to progress to malignancy in some cases.

  7. Wildlife specimen collection, preservation, and shipment

    White, C. LeAnn; Dusek, Robert J.; Franson, J. Christian; Friend, Milton; Gibbs, Samantha E.J.; Wild, Margaret A.

    2015-01-01

    Specimens are used to provide supporting information leading to the determination of the cause of disease or death in wildlife and for disease monitoring or surveillance. Commonly used specimens for wildlife disease investigations include intact carcasses, tissues from carcasses, euthanized or moribund animals, parasites, ingested food, feces, or environmental samples. Samples from live animals or the environment (e.g., contaminated feed) in the same vicinity as a mortality event also may be helpful. The type of specimen collected is determined by availability of samples and biological objectives. Multiple fresh, intact carcasses from affected species are the most useful in establishing a cause for a mortality event. Submission of entire carcasses allows observation of gross lesions and abnormalities, as well as disease testing of multiple tissues. Samples from live animals may be more appropriate when sick animals cannot be euthanized (e.g., threatened or endangered species) or for research and monitoring projects examining disease or agents circulating in apparently healthy animals or those not exhibiting clinical signs. Samples from live animals may include collections of blood, hair, feathers, feces, or ectoparasites, or samples obtained by swabbing lesions or orifices. Photographs and videos are useful additions for recording field and clinical signs and conveying conditions at the site. Collection of environmental samples (e.g., feces, water, feed, or soil) may be appropriate when animals cannot be captured for sampling or the disease agent may persist in the environment. If lethal collection is considered necessary, biologists should refer to the policies, procedures, and permit requirements of their institution/facility and the agency responsible for species management (U.S. Fish and Wildlife Service or State natural resource agency) prior to use in the field. If threatened or endangered species are found dead, or there is evidence of illegal take, field

  8. Bright field electron microscopy of biological specimens

    Johansen, B.V.

    1976-01-01

    A preirradiation procedure is described which preserves negatively stained morphological features in bright field electron micrographs to a resolution of about 1.2 nm. Prior to microscopy the pre-irradiation dose (1.6 x 10 -3 C cm -2 ) is given at low electron optical magnification at five different areas on the grid (the centre plus four 'corners'). This pre-irradiation can be measured either with a Faraday cage or through controlled exposure-developing conditions. Uranyl formate stained T2 bacteriophages and stacked disk aggregates of Tobacco Mosaic Virus (TMV) protein served as test objects. A comparative study was performed on specimens using either the pre-irradiation procedure or direct irradiation by the 'minimum beam exposure' technique. Changes in the electron diffraction pattern of the stain-protein complex and the disappearance of certain morphological features in the specimens were both used in order to compare the pre-irradiation method with the direct exposure technique. After identical electron exposures the pre-irradiation approach gave a far better preservation of specimen morphology. Consequently this procedure gives the microscopist more time to select and focus appropriate areas for imaging before deteriorations take place. The investigation also suggested that microscopy should be carried out between 60,000 and 100,000 times magnification. Within this magnification range, it is possible to take advantage of the phase contrast transfer characteristics of the objective lens while the electron load on the object is kept at a moderate level. Using the pre-irradiation procedure special features of the T2 bacteriophage morphology could be established. (author)

  9. Development of fatigue life evaluation method using small specimen

    Nogami, Shuhei; Nishimura, Arata; Wakai, Eichi; Tanigawa, Hiroyasu; Itoh, Takamoto; Hasegawa, Akira

    2013-01-01

    For developing the fatigue life evaluation method using small specimen, the effect of specimen size and shape on the fatigue life of the reduced activation ferritic/martensitic steels (F82H-IEA, F82H-BA07 and JLF-1) was investigated by the fatigue test at room temperature in air using round-bar and hourglass specimens with various specimen sizes (test section diameter: 0.85–10 mm). The round-bar specimen showed no specimen size and no specimen shape effects on the fatigue life, whereas the hourglass specimen showed no specimen size effect and obvious specimen shape effect on it. The shorter fatigue life of the hourglass specimen observed under low strain ranges could be attributed to the shorter micro-crack initiation life induced by the stress concentration dependent on the specimen shape. On the basis of this study, the small round-bar specimen was an acceptable candidate for evaluating the fatigue life using small specimen

  10. 14 CFR 120.11 - Refusal to submit to a drug or alcohol test by a Part 61 certificate holder.

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Refusal to submit to a drug or alcohol test...: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Individuals Certificated Under Parts 61, 63, and 65 § 120.11 Refusal to submit to a drug or alcohol test by a Part 61 certificate holder. (a) This...

  11. 14 CFR 120.15 - Refusal to submit to a drug or alcohol test by a Part 65 certificate holder.

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Refusal to submit to a drug or alcohol test...: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Individuals Certificated Under Parts 61, 63, and 65 § 120.15 Refusal to submit to a drug or alcohol test by a Part 65 certificate holder. (a) This...

  12. 14 CFR 120.13 - Refusal to submit to a drug or alcohol test by a Part 63 certificate holder.

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Refusal to submit to a drug or alcohol test...: CERTIFICATION AND OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Individuals Certificated Under Parts 61, 63, and 65 § 120.13 Refusal to submit to a drug or alcohol test by a Part 63 certificate holder. (a) This...

  13. 48 CFR 339.7001 - Request for approval to make an award to other than a GSA BPA holder.

    2010-10-01

    ... Use of General Services Administration Blanket Purchase Agreements for Independent Risk Analysis... micro-purchase threshold, that obtaining the required services from a source other than a GSA BPA holder... include additional supporting rationale to document the best value decision, as appropriate. ...

  14. 14 CFR 193.17 - How must design and production approval holders handle information they receive from the FAA...

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false How must design and production approval... REGULATIONS PROTECTION OF VOLUNTARILY SUBMITTED INFORMATION § 193.17 How must design and production approval... under § 193.9(a)(2) to the holders of design approvals of production approvals issued by the FAA, the...

  15. Ultrafine-grained porous titanium and porous titanium/magnesium composites fabricated by space holder-enabled severe plastic deformation

    Qi, Yuanshen, E-mail: yuanshen.qi@monash.edu [Centre for Advanced Hybrid Materials, Department of Materials Engineering, Monash University, Clayton, Victoria 3800 (Australia); Contreras, Karla G. [Monash Institute of Medical Engineering, Faculty of Engineering, Monash University, Clayton, Victoria 3800 (Australia); Jung, Hyun-Do [Liquid Processing & Casting Technology R& D Group, Korea Institute of Industrial Technology, Incheon 406-840 (Korea, Republic of); Department of Materials Science and Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Kim, Hyoun-Ee [Department of Materials Science and Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of); Advanced Institutes of Convergence Technology, Seoul National University, Gwanggyo, Yeongtong-gu, Suwon-si, Gyeonggi-do 443-270 (Korea, Republic of); Lapovok, Rimma [Centre for Advanced Hybrid Materials, Department of Materials Engineering, Monash University, Clayton, Victoria 3800 (Australia); Estrin, Yuri, E-mail: yuri.estrin@monash.edu [Centre for Advanced Hybrid Materials, Department of Materials Engineering, Monash University, Clayton, Victoria 3800 (Australia); Laboratory of Hybrid Nanostructured Materials, NUST MISiS, Moscow 119490 (Russian Federation)

    2016-02-01

    Compaction of powders by equal channel angular pressing (ECAP) using a novel space holder method was employed to fabricate metallic scaffolds with tuneable porosity. Porous Ti and Ti/Mg composites with 60% and 50% percolating porosity were fabricated using powder blends with two kinds of sacrificial space holders. The high compressive strength and good ductility of porous Ti and porous Ti/Mg obtained in this way are believed to be associated with the ultrafine grain structure of the pore walls. To understand this, a detailed electron microscopy investigation was employed to analyse the interface between Ti/Ti and Ti/Mg particles, the grain structures in Ti particles and the topography of pore surfaces. It was found that using the proposed compaction method, high quality bonding between particles was obtained. Comparing with other powder metallurgy methods to fabricate Ti with an open porous structure, where thermal energy supplied by a laser beam or high temperature sintering is essential, the ECAP process conducted at a relatively low temperature of 400 °C was shown to produce unique properties. - Highlights: • Porous Ti and porous Ti/Mg composite scaffolds were fabricated successfully. • Space holder-enabled severe plastic deformation was first used in this application. • Silicon particles as sacrificial space holders were used for the first time. • Ultrafine-grained microstructure and good bonding between particles were obtained. • Good preosteoblast cell response to as-manufactured porous Ti was achieved.

  16. Determinants of Increasing Duration of First Unemployment among First Degree Holders in Rwanda: A Logistic Regression Analysis

    Niragire, François; Nshimyiryo, Alphonse

    2017-01-01

    Unexpectedly, the duration of first unemployment among first degree holders has quickly increased in Rwanda after considerable loss of the skilled labour during the war and Genocide perpetrated against Tutsi in 1994. The time it takes a higher education graduate to land a first employment is a key indicator for the evaluation of and optimal…

  17. Whether power holders construe their power as responsibility or opportunity influences their tendency to take advice from others

    de Wit, F.R.C.; Scheepers, D.; Ellemers, N.; Sassenberg, Kai; Scholl, Annika

    Empirical evidence suggests that power elicits a generic tendency to disregard advice. We examined different responses power holders may show in their tendency to take advice depending on the construal of power. We report a field study and an experiment among managers and other powerful

  18. Measured thermal and fast neutron fluence rates for ATF-1 holders during ATR cycle 158B/159A

    Smith, Larry Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Miller, David Torbet [Idaho National Lab. (INL), Idaho Falls, ID (United States); Walker, Billy Justin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-11-01

    This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 158B/159A which were measured by the Radiation Measurements Laboratory (RML).

  19. Power Holders and Social Dynamics of Participatory Development and Reconstruction: Cases from the Democratic Republic of Congo

    Kyamusugulwa, P.M.; Hilhorst, D.

    2015-01-01

    One of the challenges of participatory development and reconstruction programs is how and where to engage with power holders. This paper analyses the dynamics of power relations within a community-driven reconstruction program in the Democratic Republic of Congo. It shows that, in some

  20. The Two-Year College as a First Choice, Second Chance Institution for Baccalaureate-Degree Holders

    Townsend, Barbara K.

    2009-01-01

    This study focused on degree-seeking baccalaureate-degree holders at one two-year technical institute in the Midsouth to determine why they chose to study at the two-year college and how they compared their two-year college experience with their baccalaureate educational experience. Findings indicated the technical college was their first choice…

  1. Recent advances in FIB-TEM specimen preparation techniques

    Li Jian; Malis, T.; Dionne, S.

    2006-01-01

    Preparing high-quality transmission electron microscopy (TEM) specimens is of paramount importance in TEM studies. The development of the focused ion beam (FIB) microscope has greatly enhanced TEM specimen preparation capabilities. In recent years, various FIB-TEM foil preparation techniques have been developed. However, the currently available techniques fail to produce TEM specimens from fragile and ultra-fine specimens such as fine fibers. In this paper, the conventional FIB-TEM specimen preparation techniques are reviewed, and their advantages and shortcomings are compared. In addition, a new technique suitable to prepare TEM samples from ultra-fine specimens is demonstrated

  2. 17 CFR 270.32a-2 - Exemption for initial period from vote of security holders on independent public accountant for...

    2010-04-01

    ... from vote of security holders on independent public accountant for certain registered separate accounts... from vote of security holders on independent public accountant for certain registered separate accounts... 32(a) of the Act that selection of an independent public accountant shall have been submitted for...

  3. Initial experience using a robotic-driven laparoscopic needle holder with ergonomic handle: assessment of surgeons' task performance and ergonomics.

    Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M

    2017-12-01

    The objective of this study is to assess the surgeons' performance and ergonomics during the use of a robotic-driven needle holder in laparoscopic suturing tasks. Six right-handed laparoscopic surgeons with different levels of experience took part in this study. Participants performed a set of three different intracorporeal suturing tasks organized in ten trials during a period of five weeks. Surgeons used both conventional (Conv) and robotic (Rob) laparoscopic needle holders. Precision using the surgical needle, quality of the intracorporeal suturing performance, execution time and leakage pressure for the urethrovesical anastomosis, as well as the ergonomics of the surgeon's hand posture, were analyzed during the first, fifth and last trials. No statistically significant differences in precision and quality of suturing performance were obtained between both groups of instruments. Surgeons required more time using the robotic instrument than using the conventional needle holder to perform the urethrovesical anastomosis, but execution time was significantly reduced after training ([Formula: see text] 0.05). There were no differences in leakage pressure for the anastomoses carried out by both instruments. After training, novice surgeons significantly improved the ergonomics of the wrist ([Formula: see text] 0.05) and index finger (Conv: 36.381[Formula: see text], Rob: 30.389[Formula: see text]; p = 0.024) when using the robotic instrument compared to the conventional needle holder. Results have shown that, although both instruments offer similar technical performance, the robotic-driven instrument results in better ergonomics for the surgeon's hand posture compared to the use of a conventional laparoscopic needle holder in intracorporeal suturing.

  4. Corrosion testing of uranium silicide fuel specimens

    Bourns, W.T.

    1968-09-01

    U 3 Si is the most promising high density natural uranium fuel for water-cooled power reactors. Power reactors fuelled with this material are expected to produce cheaper electricity than those fuelled with uranium dioxide. Corrosion tests in 300 o C water preceded extensive in-reactor performance tests of fuel elements and bundles. Proper heat-treatment of U-3.9 wt% Si gives a U 3 5i specimen which corrodes at less than 2 mg/cm 2 h in 300 o C water. This is an order of magnitude lower than the maximum corrosion rate tolerable in a water-cooled reactor. U 3 Si in a defected unbonded Zircaloy-2 sheath showed only a slow uniform sheath expansion in 300 o C water. All tests were done under isothermal conditions in an out-reactor loop. (author)

  5. A system for mapping radioactive specimens

    Britten, R.J.; Davidson, E.H.

    1988-01-01

    A system for mapping radioactive specimens comprises an avalanche counter, an encoder, pre-amplifier circuits, sample and hold circuits and a programmed computer. The parallel plate counter utilizes avalanche event counting over a large area with the ability to locate radioactive sources in two dimensions. When a beta ray, for example, enters a chamber, an ionization event occurs and the avalanche effect multiplies the event and results in charge collection on the anode surface for a limited period of time before the charge leaks away. The encoder comprises a symmetrical array of planar conductive surfaces separated from the anode by a dielectric material. The encoder couples charge currents, the amlitudes of which define the relative position of the ionization event. The amplitude of coupled current, delivered to pre-amplifiers, defines the location of the event. (author) 12 figs

  6. Corrosion testing of uranium silicide fuel specimens

    Bourns, W T

    1968-09-15

    U{sub 3}Si is the most promising high density natural uranium fuel for water-cooled power reactors. Power reactors fuelled with this material are expected to produce cheaper electricity than those fuelled with uranium dioxide. Corrosion tests in 300{sup o}C water preceded extensive in-reactor performance tests of fuel elements and bundles. Proper heat-treatment of U-3.9 wt% Si gives a U{sub 3}5i specimen which corrodes at less than 2 mg/cm{sup 2} h in 300{sup o}C water. This is an order of magnitude lower than the maximum corrosion rate tolerable in a water-cooled reactor. U{sub 3}Si in a defected unbonded Zircaloy-2 sheath showed only a slow uniform sheath expansion in 300{sup o}C water. All tests were done under isothermal conditions in an out-reactor loop. (author)

  7. 10 CFR 26.165 - Testing split specimens and retesting single specimens.

    2010-01-01

    ... (c), as applicable. If the specimen in Bottle A is free of any evidence of drugs or drug metabolites... suitable inquiry conducted under the provisions of § 26.63 or to any other inquiry or investigation... records must be provided to personnel conducting reviews, inquiries into allegations, or audits under the...

  8. A non-destructive DNA sampling technique for herbarium specimens.

    Shepherd, Lara D

    2017-01-01

    Herbarium specimens are an important source of DNA for plant research but current sampling methods require the removal of material for DNA extraction. This is undesirable for irreplaceable specimens such as rare species or type material. Here I present the first non-destructive sampling method for extracting DNA from herbarium specimens. DNA was successfully retrieved from robust leaves and/or stems of herbarium specimens up to 73 years old.

  9. Miniature tensile test specimens for fusion reactor irradiation studies

    Klueh, R.L.

    1985-01-01

    Three miniature sheet-type tensile specimens and a miniature rod-type specimen are being used to determine irradiated tensile properties for alloy development for fusion reactors. The tensile properties of type 316 stainless steel were determined with these different specimens, and the results were compared. Reasonably good agreement was observed. However, there were differences that led to recommendations on which specimens are preferred. 4 references, 9 figures, 6 tables

  10. Elastic-plastic analysis of the SS-3 tensile specimen

    Majumdar, S.

    1998-01-01

    Tensile tests of most irradiated specimens of vanadium alloys are conducted using the miniature SS-3 specimen which is not ASTM approved. Detailed elastic-plastic finite element analysis of the specimen was conducted to show that, as long as the ultimate to yield strength ratio is less than or equal to 1.25 (which is satisfied by many irradiated materials), the stress-plastic strain curve obtained by using such a specimen is representative of the true material behavior

  11. Molecular Auditing: An Evaluation of Unsuspected Tissue Specimen Misidentification.

    Demetrick, Douglas J

    2018-06-18

    Context Specimen misidentification is the most significant error in laboratory medicine, potentially accounting for hundreds of millions of dollars in extra health care expenses and significant morbidity in patient populations in the United States alone. New technology allows the unequivocal documentation of specimen misidentification or contamination; however, the value of this technology currently depends on suspicion of the specimen integrity by a pathologist or other health care worker. Objective To test the hypothesis that there is a detectable incidence of unsuspected tissue specimen misidentification among cases submitted for routine surgical pathology examination. Design To test this hypothesis, we selected specimen pairs that were obtained at different times and/or different hospitals from the same patient, and compared their genotypes using standardized microsatellite markers used commonly for forensic human DNA comparison in order to identify unsuspected mismatches between the specimen pairs as a trial of "molecular auditing." We preferentially selected gastrointestinal, prostate, and skin biopsies because we estimated that these types of specimens had the greatest potential for misidentification. Results Of 972 specimen pairs, 1 showed an unexpected discordant genotype profile, indicating that 1 of the 2 specimens was misidentified. To date, we are unable to identify the etiology of the discordance. Conclusions These results demonstrate that, indeed, there is a low level of unsuspected tissue specimen misidentification, even in an environment with careful adherence to stringent quality assurance practices. This study demonstrates that molecular auditing of random, routine biopsy specimens can identify occult misidentified specimens, and may function as a useful quality indicator.

  12. Assessment of conditions of the spent nuclear fuel stored in the stainless steel channel-holders

    Pesic, M.; Sotic, O.; Cupac, S.; Maksin, T.; Dasic, N.

    2003-01-01

    The IAEA technical co-operation project 'Safe Removal of Spent Fuel of the Vinca RA Research Reactor' is carried out at the Vinca Institute of Nuclear Sciences, Belgrade, Serbia and Montenegro, since January 2003. Present activities will provide up-to-date information on the conditions of the spent nuclear fuel, stored in the stainless steel channel-holders ('chekhols') and on the water quality in the storage basins. Water samples taken out from the chekhols and the basins are measured to determine their activity and chemical parameters. Until September 2003, about 1/3 of the chekhols containing spent fuel elements with initial enrichment of 2% and 80% of uranium were inspected. High activity of Cs-137 was found in several water samples taken out from chekhols. All water samples show very high electrical conductivity, while those taken from the basins show the presence of chlorides and aluminium ions, too. Information on established procedures and measuring results are given in this paper. The obtained results, so far, show that the spent nuclear fuel elements are leaking in about 10% of chekhols. (author)

  13. Post-purchase reassessment and improvement of neuroendoscope holder: importance of physician-manufacturer communication.

    Ogawa, Yoshikazu; Nakata, Yusuke; Tominaga, Teiji

    2014-01-01

    Modern medical management requires constant quality improvement of the various instruments used for surgical procedures. Higher quality, less complicated handling, and reduced maintenance are all desirable qualities. However, any improvements in instrumentation require that surgeons must clearly understand the application of the device by adherence to the manufacturer's instructions. The weakness of this one-way information flow depends on the low interest among medical personnel for post-purchase reassessment. Service industries have research departments to investigate the post-purchase behavior of customers, and service recovery is considered essential to retain customers after service failure. All service providers can suffer service failures, and even the best providers may make errors in delivering service. Such an approach has been increasingly adopted in the risk management at medical institutions. We report our clinical trials of the post-purchase reassessment and product improvement of surgical instrumentation. Medical personnel reassessed the use of a newly developed endoscope holder based on the manufacturer's manual and made recommendations for possible improvements, which were examined by the manufacturer. Simple but important improvement was achieved for reducing the instability and uncertainty of instrument fixation. This bi-directional post-purchase communication between medical personnel and manufacturers can improve risk management in medical institutions.

  14. The effect of simulated flash heating pasteurisation and Holder pasteurisation on human milk oligosaccharides.

    Daniels, Brodie; Coutsoudis, Anna; Autran, Chloe; Amundson Mansen, Kimberly; Israel-Ballard, Kiersten; Bode, Lars

    2017-08-01

    Human milk oligosaccharides (HMOs) have important protective functions in human milk. A low-cost remote pasteurisation temperature-monitoring system has been designed using FoneAstra, a cell phone-based networked sensing system to monitor simulated flash heat pasteurisation. To compare the pasteurisation effect on HMOs of the FoneAstra FH method with the current Sterifeed Holder method used by human milk banks. Donor human milk samples (n = 48) were obtained from a human milk bank and pasteurised using the two pasteurisation methods. HMOs were purified from samples and labelled before separation using high-performance liquid chromatography. Concentrations of total HMOs, sialylated and fucosylated HMOs and individual HMOs using the two pasteurisation methods were compared using repeated-measures ANOVA. The study demonstrated no difference in total concentration of HMOs between the two pasteurisation methods and a small but significant increase in the total concentration of HMOs regardless of pasteurisation methods compared with controls (unpasteurised samples) (pmilk and therefore is a possible alternative for providing safely sterilised human milk for low- and middle-income countries.

  15. DIAGNOSIS OF BANKRUPTCY RISK IN THE FURNITURE INDUSTRY USING THE CANON-HOLDER AND ALTMAN MODELS

    Radu MĂRGINEAN

    2015-06-01

    Full Text Available The financial and economic crisis that started in 2008 caused negative effects felt by the entire European economy, affecting more or less all of the world's economies. This paper aims to study the diagnosis of bankruptcy risk using the Canon-Holder and Altman methods, from a theoretical point of view and with practical examples on a company in the furniture industry in Romania. In a context of economic uncertainty, the relevance of such an analysis designed to quantify the risk of bankruptcy for companies is the default. The financial data used is real and descriptively analyzed, we analyzed a period of eight years, between 2006-2013. As a method of analysis complementary to the financial analysis of the background of companies, the diagnosis of bankruptcy risk using the score method, using the specific models known in the specialty literature, brings relevant information concerning the problem of risk assessment. We concluded in the case study the opportunity of such an analysis for the furniture industry through the results obtained in the case studies, the method is a useful tool, especially for the practitioners in the sector.

  16. Quality control and enhancement of microwelds for Ir-192 sample holders

    Lopez, Alcides; Medina, Max; Cavero, Luis

    2013-01-01

    This study shows the micro quality results of tungsten inert gas welds on stainless steel AISI 304 of 5 sample holders for 30 discs by 3 mm diameter and 0.5 mm thick of Ir-192 sources produced in the Radioisotope Production Plant (RPP) of IPEN, generally used in industrial gammagraphy. Macrographic and conventional metallographic analysis were performed to measure the amplitude, thickness and centering parameters of the weld bead, centered data have helped to determine the parameters for welds with good quality, showing defects due to the misaligned glass lens, low magnification image and high visual angle of incidence across the 200 mm security leaded glass giving a low quality weld image due to the low magnification, large chromatic aberration resulting in a weld outside the seam, this problem was solved by changing the old optical visualization system by an external telescope specially designed for this purpose and raising the workbench so that the optical telescope axis and the weld are horizontally, achieving more rapid processes, reliable and reproducible, this new system has proved more convenient, reliable and reproducible. (authors).

  17. Impact of Small Holder Dairy Farm on the Air Quality in Gunungpati District, Semarang Municipality

    Widiastuti, E.; Kustono; Adiarto; Nurliyani; Sugiharto, S.

    2018-02-01

    The study aimed to investigate the impact of small holder dairy farm on the air quality in the farm and surrounding area. The study was conducted in three farmer groups in the District of Gunungpati, including the farmer groups in the villages of Nangkasawit, Plalangan and Sumurejo. Samplings of air quality were conducted in four points (locations), i.e., inside the barn, 100 m, 200 m and 300 m from the area of farm. Parameters observed were emission of NH3 CO2, H2S and CH4. Results showed that the levels of NH3 in the barn, 100 m, 200 m and 300 m from the farm area in Nangkasawit village were 0.211, 0.107, 0.104 and 0,035 ppm, respectively. The levels of NH3 in Plalangan village were 0.289, 0.231, 0.13 and 0.108 ppm, respectively, and in Sumurejo village were 0.109, 0.110, 0.082 and 0.046 ppm, respectively. The levels of H2S in Nangkasawit, Plalangan and Sumurejo villages at the entire points of observations were air quality was better (lower contamination) with the farther distance of locations from the barn.

  18. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders

    Özbilen, Sedat [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); Gazi University, Faculty of Technology, Department of Metallurgical and Materials Engineering, Teknikokullar, Ankara (Turkey); Liebert, Daniela [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); Beck, Tilmann [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany); University of Kaiserslautern, Lehrstuhl für Werkstoffkunde (WKK), D-67663 Kaiserslautern (Germany); Bram, Martin, E-mail: m.bram@fz-juelich.de [Forschungszentrum Jülich, Institute of Energy and Climate Research (IEK), 52425 Jülich (Germany)

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34–0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ{sub min} and σ{sub max} were varied systematically to estimate the fatigue limit (~ 4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. - Highlights: • Systematic variation of the oxygen content from 0.34 to 0.58 wt.%. • Systematic study of the relationship between fatigue limit and oxygen content. • Critical oxygen equivalent seems to be 0.35 wt.% to avoid embrittlement. • Identification of the failure modes by light microscopy, SEM and EBSD.

  19. Shaft seals with an easily removable cylinder holder for low-pressure steam turbines

    Zakharov, A. E.; Rodionov, D. A.; Pimenov, E. V.; Sobolev, A. S.

    2016-01-01

    The article is devoted to the problems that occur at the operation of LPC shaft seals (SS) of turbines, particularly, their bearings. The problems arising from the deterioration of oil-protecting rings of SS and bearings and also the consequences in which they can result are considered. The existing SS housing construction types are considered. Their operational features are specified. A new SS construction type with an easily removable holder is presented. The construction of its main elements is described. The sequence of operations of the repair personnel at the restoration of the new SS type spacings is proposed. The comparative analysis of the new and the existing SS construction types is carried out. The assessment results of the efficiency, the operational convenience, and the economic effect after the installation of the new type seals are given. The conclusions about the offered construction prospects are made by results of the comparative analysis and the carried-out assessment. The main advantage of this design is the possibility of spacings restoration both in SS and in oil-protecting rings during a short-term stop of a turbine, even without its cooling. This construction was successfully tested on the working K-300-23.5 LMP turbine. However, its adaptation for other turbines is quite possible.

  20. A Simple Refining Technique of Coconut Oil for Small Holder Industries

    Sugeng Triyono

    2009-04-01

    Full Text Available A simple refining equipment and process for small holder industries of edible coconut oil has beeninvestigated. The equipment consisted of 20-L filtering and NaOH neutralization bottles. Filtration wasintended to remove impurities such as gums and pigment, while neutralization was to remove free fattyacids (FFA and other non-fat materials. In the experiment, the crude coconut oil was found to have impurityof 0.16%, FFA of 8.02%, saponification number of 270, and water content of 0.33%. The results showed thateither granular activated carbon (GAC or zeolite filtration can be chosen individually to remove physicalimpurity. The GAC or zeolite-filtered coconut oil contained impurity less than the SNI standard of 0.05%.In term of FFA; however, the NaOH neutralized coconut oil did not meet the SNI standard of 0.3%. AfterNaOH neutralization, the GAC filtered oil contained 1.20% FFA; while the zeolite filtered oil contained1.32%. These FFA contents were definitely higher than the SNI standard, but could satisfy APCC standardfor grade IV coconut oil which is 5%. The refined coconut oils could also satisfy the SNI standard ofsaponification number which is 196 – 206 at minimum. In term of water content, either the filtered or theneutralized oil could also satisfy the SNI standard of 0.3%. In short, the proposed technique could helpfarmers refine their raw coconut oil, and hopefully improve its marketability.

  1. Fatigue behavior of highly porous titanium produced by powder metallurgy with temporary space holders.

    Özbilen, Sedat; Liebert, Daniela; Beck, Tilmann; Bram, Martin

    2016-03-01

    Porous titanium cylinders were produced with a constant amount of temporary space holder (70 vol.%). Different interstitial contents were achieved by varying the starting powders (HDH vs. gas atomized) and manufacturing method (cold compaction without organic binders vs. warm compaction of MIM feedstocks). Interstitial contents (O, C, and N) as a function of manufacturing were measured by chemical analysis. Samples contained 0.34-0.58 wt.% oxygen, which was found to have the greatest effect on mechanical properties. Quasi-static mechanical tests under compression at low strain rate were used for reference and to define parameters for cyclic compression tests. Not unexpectedly, increased oxygen content increased the yield strength of the porous titanium. Cyclic compression fatigue tests were conducted using sinusoidal loading in a servo-hydraulic testing machine. Increased oxygen content was concomitant with embrittlement of the titanium matrix, resulting in significant reduction of compression cycles before failure. For samples with 0.34 wt.% oxygen, R, σ(min) and σ(max) were varied systematically to estimate the fatigue limit (~4 million cycles). Microstructural changes induced by cyclic loading were then characterized by optical microscopy, SEM and EBSD. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Design of specimen for weld residual stress simulation

    Kim, Jin Weon; Park, Jong Sun; Lee, Kyung Soo

    2008-01-01

    The objective of this study is to design a laboratory specimen for simulating residual stress of circumferential butt welding of pipe. Specimen type and method for residual stress generation were proposed based on the review of prior studies and parametric finite element simulation. To prove the proposed specimen type and loading method, the residual stress was generated using the designed specimen by applying proposed method and was measured. The measured residual stress using X-ray diffraction reasonably agreed with the results of finite element simulation considered in the specimen design. Comparison of residual strains measured at several locations of specimen and given by finite element simulation also showed good agreement. Therefore, it is indicated that the designed specimen can reasonably simulate the residual stress of circumferential butt welding of pipe

  3. [Complaints by private health insurance policy-holders to the Consumer Protection Bureau in Argentina, 2000-2008].

    Luzuriaga, María José; Spinelli, Hugo

    2014-05-01

    This paper analyzes problems experienced by policy-holders of voluntary private health insurance plans in Argentina when insurance companies fail to comply with the Consumer Protection Code. The sample consisted of consumer complaints filed with the Consumer Protection Bureau and rulings by the Bureau from 2000 to 2008. One striking issue was recurrent non-compliance with services included in the Mandatory Medical Program and the companies' attempts to blame policy-holders. According to the study, the lack of an information system hinders scientific studies to adequately address the problem. Thus, a comparison with studies on health insurance in other Latin American countries highlighted the importance of such research, the relationship to health systems, constraints on use and denial of citizens' rights to healthcare, and the increasing judicialization of healthcare provision.

  4. Precision tool holder with flexure-adjustable, three degrees of freedom for a four-axis lathe

    Bono, Matthew J [Pleasanton, CA; Hibbard, Robin L [Livermore, CA

    2008-03-04

    A precision tool holder for precisely positioning a single point cutting tool on 4-axis lathe, such that the center of the radius of the tool nose is aligned with the B-axis of the machine tool, so as to facilitate the machining of precision meso-scale components with complex three-dimensional shapes with sub-.mu.m accuracy on a four-axis lathe. The device is designed to fit on a commercial diamond turning machine and can adjust the cutting tool position in three orthogonal directions with sub-micrometer resolution. In particular, the tool holder adjusts the tool position using three flexure-based mechanisms, with two flexure mechanisms adjusting the lateral position of the tool to align the tool with the B-axis, and a third flexure mechanism adjusting the height of the tool. Preferably, the flexures are driven by manual micrometer adjusters. In this manner, this tool holder simplifies the process of setting a tool with sub-.mu.m accuracy, to substantially reduce the time required to set the tool.

  5. An optimum source neutron spectrum and holder shape for extra-corporal treatment of liver cancer by BNCT

    Nievaart, Sander; Moss, Ray; Sauerwein, Wolfgang; Malago, Massimo; Kloosterman, Jan Leen; Hagen, Tim van der; Dam, Hugo van

    2006-01-01

    In extra-corporal treatment of liver cancer by BNCT, it is desired to have an as homogeneous as possible thermal neutron field throughout the organ. Previous work has shown that when using an epithermal neutron beam, the shape of the holder in which the liver is placed is the critical factor. This study develops the notion further as to what is the optimum neutron spectrum to perform such treatments. In the design calculations, when using Monte Carlo techniques, it is shown that when the expected contributions of the source neutrons in every part of the liver is calculated, a linear optimization scheme such as the Simplex method results in a mix of thermal and epithermal source neutrons to get the highest homogeneity for the thermal neutron field. This optimisation method is demonstrated in 3 holder shapes: cuboid, cylindrical and spherical with each 3 volumes of 2, 4 and 6 litres. A 10 cm thick cuboid model, irradiated from both sides gives the highest homogeneity. The spherical (rotating) holder has the lowest homogeneity but the highest contribution of every source neutron to the thermal neutrons in the liver. This can be advantageous when using a relatively small sized neutron beam with a low strength. (author)

  6. Improvement of rotary specimen rack design

    Batch, J.M.; Gietzen, A.J.

    1978-01-01

    A redesign and verification test program has been completed on a new Rotary Specimen Rack ('Lazy Susan') design for the TRIGA Mark III. The purpose of the redesign was to solve a rotation problem which occurred at power levels of about 1 MW and above. The previous redesign effort on the Mark II-type lazy susan was made in 1967 when the bearing was changed to use stellite balls, spring-type separators and stainless-steel bearing races. An extensive test program at that time showed that the design gave excellent service under all anticipated operating conditions. Fifteen of these units have been installed in the past ten years and have been essentially trouble-free. Although the bearing design for the Mark III was very similar, the component layout was such that irradiation-induced heating with associated thermal expansion resulted in decreased bearing clearance and an increase in the required driving torque. The solution involved redesign and re-arrangement of the rack drive mechanism. A series of stringent operational proof tests were made under high temperature and temperature differential conditions which proved successful operation of the new design. The severe conditions under which these tests were performed uncovered further difficulties with the bearing and led to a re-evaluation of the bearing design. A new design was developed in which the spring separators were replaced by similar sized, cylindrical graphite spacers. The entire series of operational and life tests were repeated and the performance was outstanding. Acceptable wear characteristics of the spacers were verified and the bearing was noticeably smoother and quieter than with previous designs. A Mark III lazy susan of this new design was installed in a TRIGA about one year ago and operated at power levels up to 2 MW with excellent performance. The Mark II design has now been changed to incorporate the new drive and bearing design proven for the Mark III. (author)

  7. Technique of manufacturing specimen of irradiated fuel rods

    Min, Duck Seok; Seo, Hang Seok; Min, Duck Kee; Koo, Dae Seo; Lee, Eun Pyo; Yang, Song Yeol

    1999-04-01

    Technique of manufacturing specimen of irradiated fuel rods to perform efficient PIE is developed by analyzing the relation between requiring time of manufacturing specimen and manufacturing method in irradiated fuel rods. It takes within an hour to grind 1 mm of specimen thickness under 150 rpm in speed of grinding, 600 g gravity in force using no.120, no.240, no.320 of grinding paper. In case of no.400 of grinding paper, it takes more an hour to grind the same thickness as above. It takes up to a quarter to grind 80-130 μm in specimen thickness using no.400 of grinding paper. When grinding time goes beyond 15 minutes, the grinding thickness of specimen does not exist. The polishing of specimen with 150 Rpms in speed of grinding machine, 600 g gravity in force, 10 minutes in polishing time using diamond paste 15 μm on polishing cloths amounts to 50 μm in specimen thickness. In case of diamond paste 9 μm on polishing cloth, the polishing of specimen amounts to 20 μm. The polishing thickness of specimen with 15 minutes in polishing time using 6 μm, 3 μm, 1 μm, 1/4 μm does not exist. Technique of manufacturing specimen of irradiated fuel rods will have application to the destructive examination of PIE. (author). 6 refs., 1 tab., 10 figs

  8. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    Lalander, Cecilia Helena; Komakech, Allan John; Vinnerås, Björn

    2015-01-01

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies

  9. THE LEGAL PROTECTION FOR REAL LAND RIGHT HOLDER IN CASE OF FORGED RINCIK

    Nirwana Nirwana

    2017-12-01

    Full Text Available The legal Protection For Real Land Right Holder in Case of Forged Rincik. The research aimed to investigate (1 the legal protection for the land owner whose possession was based on rincik evidence, and (2 the legal protection on the good-will buyer based on the forged rincik document used in the land sale transaction. This was the normative legal research, also called the library research or documentary study because the research was only conducted on the written regulations or other legal materials or secondary data consisting of the primary and secondary legal materials. The interview was performed to strengthen the theories and opinions in the research. The research also used the Secondary data. the data were analysed and presented using the qualitative descriptive method. The research result indicate that: (1 the real land owner with rincik possession issued after the year 1960 based on the decision of Indonesian Supreme Court No. 560K / PID / 2008 has not been fully protected due to the fact that the seller is funished for forging the rincik., returning the right to the land owner can not be carried out due to the decision of Indonesian Supreme Court Number. 482 / PK / Pdt / 2014 which make the buyer win, while the real land owner is the directed to sue the land seller to give the compensation: and (2 the legal protection on the good faith buyer based on forget rincik in the land sale transaction has been fully protected and has the ringt to possess the land based on the decision of Indonesian Supreme Court Number. 482/PK/Pdt/2014 because the buyer has bought the land in the presence of Temporary Land Title Registar.

  10. Vermicomposting as manure management strategy for urban small-holder animal farms – Kampala case study

    Lalander, Cecilia Helena, E-mail: cecilia.lalander@slu.se [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Komakech, Allan John [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden); Department of Agricultural & Bio-systems Engineering, Makerere University, Kampala (Uganda); Vinnerås, Björn [Department of Energy and Technology, Swedish University of Agricultural Sciences, Uppsala (Sweden)

    2015-05-15

    Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of worm biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies.

  11. Making mock-FNA smears from fresh surgical pathology specimens to improve smear preparation technique and to create cytohistological correlation series.

    Tibor Mezei

    Full Text Available Fine needle aspiration (FNA cytology is a well-established diagnostic method based on the microscopic interpretation of often scant cytological material; therefore, experience, good technique and smear quality are equally important in obtaining satisfactory results.We studied the use of fresh surgical pathology specimens for making so-called mock-FNA smears with the potential of cytohistological correlation. Additionally, we studied how this process aids the improvement of preparation technique and smear quality.Cytological aspirates from 32 fresh biopsy specimens from various sites: lung (20, lymph nodes (6, and breast (6 were obtained, all with a clinical diagnosis of tumor. Aspiration was performed from grossly palpable tumors. 25 G needle and Cameco-type syringe holder was used with minimal or no suction.Unfixed surgical specimens provided sufficient cytological material that resulted in good quality smears. After standard processing of specimens into microscopic sections from paraffin embedded tissues, cytohistological case-series were created. No significant alteration was reported in tissue architecture on hematoxylin-eosin stained sections after the aspiration procedure. A gradual, but steady improvement was observed in smear quality just after a few preparations.Our study proved that surgical specimens may be used as a source of cytological material to create cytohistological correlation studies and also to improve FNA cytology skills. The use of very fine gauge needle (25 G, 0,6 mm diameter during the sampling process does not alter tissue architecture therefore the final histopathological diagnosis is not compromised. We conclude that by using fresh surgical specimens useful cytohistological collections can be created both as a teaching resource and as improving experience.

  12. Design and construction of a holder to the safety handling of Cs-137 to be used in cervix cancer treatments using intracavitary brachytherapy by afterloading

    Gonzales, E.; Lea, D.

    1996-01-01

    In venezuelan public hospitals where cervix cancer treatments are performed by means of Cs-137 manual afterloading systems, the handling of the sources is done with two type of holders, metallic and plastic, the plastic holders are pieces of induced serious radio-sanitary problem such as loser of the Cs-137 source and radioactive contamination in the treatment area, this has caused the interruption of the treatments in many hospitals. This interruption had a high social cost because of the thousands women waiting for intracavitary therapy. To start again with the treatments, the metallic holders were required but there were not enough funds in the budget, because of this problem in a short time IVIS'S health physics drew and made a low price source holder. (authors). 2 figs., 2 tabs

  13. Laboratory specimens and genetic privacy: evolution of legal theory.

    Lewis, Michelle Huckaby

    2013-03-01

    Although laboratory specimens are an important resource for biomedical research, controversy has arisen when research has been conducted without the knowledge or consent of the individuals who were the source of the specimens. This paper summarizes the most important litigation regarding the research use of laboratory specimens and traces the evolution of legal theory from property claims to claims related to genetic privacy interests. © 2013 American Society of Law, Medicine & Ethics, Inc.

  14. Location specific in situ TEM straining specimens made using FIB

    Field, R.D.; Papin, P.A.

    2004-01-01

    A method has been devised and demonstrated for producing in situ straining specimens for the transmission electron microscope (TEM) from specific locations in a sample using a dual-beam focused ion beam (FIB) instrument. The specimen is removed from a polished surface in the FIB using normal methods and then attached to a pre-fabricated substrate in the form of a modified TEM tensile specimen. In this manner, specific features of the microstructure of a polished optical mount can be selected for in situ tensile straining. With the use of electron backscattered diffraction (EBSD), this technique could be extended to select specific orientations of the specimen as well

  15. Uniaxial compression tests on diesel contaminated frozen silty soil specimens

    Chenaf, D.; Stampli, N.; Bathurst, R.; Chapuis, R.P.

    1999-01-01

    Results of a uniaxial, unconfined compression test on artificial diesel-contaminated and uncontaminated frozen silty soils are discussed. The testing program involved 59 specimens. The results show that for the same fluid content, diesel contamination reduced the strength of the frozen specimens by increasing the unfrozen water content. For example, in specimens containing 50 per cent diesel oil of the fluid content by weight the maximum strength was reduced by 95 per cent compared to the strength of an uncontaminated specimen. Diesel contamination was also shown to contribute to the slippage between soil particles by acting as a lubricant, thus accelerating the loss of compressive strength.13 refs., 18 figs

  16. Quantitative X-ray microanalysis of biological specimens

    Roomans, G.M.

    1988-01-01

    Qualitative X-ray microanalysis of biological specimens requires an approach that is somewhat different from that used in the materials sciences. The first step is deconvolution and background subtraction on the obtained spectrum. The further treatment depends on the type of specimen: thin, thick, or semithick. For thin sections, the continuum method of quantitation is most often used, but it should be combined with an accurate correction for extraneous background. However, alternative methods to determine local mass should also be considered. In the analysis of biological bulk specimens, the ZAF-correction method appears to be less useful, primarily because of the uneven surface of biological specimens. The peak-to-local background model may be a more adequate method for thick specimens that are not mounted on a thick substrate. Quantitative X-ray microanalysis of biological specimens generally requires the use of standards that preferably should resemble the specimen in chemical and physical properties. Special problems in biological microanalysis include low count rates, specimen instability and mass loss, extraneous contributions to the spectrum, and preparative artifacts affecting quantitation. A relatively recent development in X-ray microanalysis of biological specimens is the quantitative determination of local water content

  17. Drone Transport of Microbes in Blood and Sputum Laboratory Specimens.

    Amukele, Timothy K; Street, Jeff; Carroll, Karen; Miller, Heather; Zhang, Sean X

    2016-10-01

    Unmanned aerial vehicles (UAVs) could potentially be used to transport microbiological specimens. To examine the impact of UAVs on microbiological specimens, blood and sputum culture specimens were seeded with usual pathogens and flown in a UAV for 30 ± 2 min. Times to recovery, colony counts, morphologies, and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based identifications of the flown and stationary specimens were similar for all microbes studied. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  18. A Debonded Sandwich Specimen Under Mixed Mode Bending (MMB)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2008-01-01

    Face/core interface crack propagation in sandwich specimens is analyzed. A thorough analysis of the typical failure modes in sandwich composites was performed in order to design the MMB specimen to promote face/core debond fracture. Displacement, compliance and energy release rate expressions...... for the MMB specimen were derived from a superposition analysis. An experimental verification of the methodology proposed was performed using MMB sandwich specimens with H100 PVC foam core and E-glass/polyester non-crimp quadro-axial [0/45/90/-45]s DBLT-850 faces. Different mixed mode loadings were applied...

  19. TEM specimen preparation of semiconductor-PMMA-metal interfaces

    Thangadurai, P.; Lumelsky, Yulia; Silverstein, Michael S.; Kaplan, Wayne D.

    2008-01-01

    Transmission electron microscopy (TEM) cross-section specimens of PMMA in contact with gold and Si were prepared by focused ion beam (FIB) and compared with plan-view PMMA specimens prepared by a dip-coating technique. The specimens were characterized by TEM and electron energy loss spectroscopy (EELS). In the cross-section specimens, the thin films of PMMA were located in a Si-PMMA-Au multilayer. Different thicknesses of PMMA films were spin-coated on the Si substrates. The thickness of the TEM specimens prepared by FIB was estimated using EELS to be 0.65 of the plasmon mean-free-path. Along the PMMA-Au interface, Au particle diffusion into the PMMA was observed, and the size of the Au particles was in the range of 2-4 nm. Dip-coating of PMMA directly on Cu TEM grids resulted in thin specimens with a granular morphology, with a thickness of 0.58 of the plasmon mean-free-path. The dip-coated specimens were free from ion milling induced artifacts, and thus serve as control specimens for comparison with the cross-sectioned specimens prepared by FIB

  20. Feasibility of scaffold production using Ti-13Nb-13Zr alloy and naphthalene as space holder

    Pinto, Persio Mozart; Komorizono, Amanda Akemy; Antonini, Leonardo; Rodrigues Junior, Durval, E-mail: persiomozart@usp.br [Universidade de Sao Paulo (USP), Lorena, SP (Brazil). Escola de Engenharia

    2016-07-01

    Full text: The tissue engineering has as goal the repairing of bone defects, usually using a synthetic structure with pores in three dimensions, named scaffold. The structure of the scaffolds present interconnected pores, with controlled porosity, according to the process used to produce the scaffold. The present work has as main objective the processing of the Ti-13Nb-13Zr alloy (percentages in weight) using the powder metallurgy technique named space-holder, to obtain porous scaffolds for osseointegration. Firstly, elementary powders of Ti, Nb, and Zr were weighted to obtain the composition 74wt.%Ti+13wt.%Nb+13wt.%Zr, such that 3.5g was direct mixed with naphthalene, named 'control' condition, and 3.5g was milled in a SPEX mill for 8h (sample MA8h), using grinding midia of tungsten carbide and isopropyl alcohol as process controlling agent. Both powders, in 'control' and MA8h conditions, were mixed with naphthalene powder (50% in volume and particle size in the range from 500μm to 1mm) for 30 minutes. The powders mixed with naftalen were pressed to obtain green bodies and sintered at 1000°C for 1h in vacuum better than 5 x 10{sup -5} mbar. The sintered samples were characterized using XRD, He picnometry, optical microscopy, SEM-EDX, and microhardness test. From the XRD results, it could be found the presence of titanium α and β phases, also present in the SEM-EDX analyses. The SEM analyses also showed, in the samples, the presence of widmantäten microstructure and a structure of pores, with size in the range from 300μm to 1mm. The observed pores were also interconnected and were connected to the surface. From the results of He picnometry and microscopy, it could be observed that the samples presented porosity in the range from 30% to 50% in volume. It could be concluded that it is possible to obtain scaffolds of the Ti-13Nb-13Zr alloy using the techniques developed in the present work. (author)

  1. Canadian Public and Stake holder Engagement Approach to a Spent Nuclear Fuel Management

    Hwang, Yong Soo; Kim, Youn Ok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Whang, Joo Ho [Kyunghee University, Yongin (Korea, Republic of)

    2008-09-15

    After Canada has struggled with a radioactive waste problem over for 20 years, the Canadian government finally found out that its approach by far has been lack of social acceptance, and needed a program such as public and stake holder engagement (PSE) which involves the public in decision-making process. Therefore, the government made a special law, called Nuclear Fuel Waste Act (NFWA), to search for an appropriate nuclear waste management approach. NFWA laid out three possible approaches which were already prepared in advance by a nuclear expert group, and required Nuclear Waste Management Organization (NWMO) to be established to report a recommendation as to which of the proposed approaches should be adopted. However, NFWA allowed NWMO to consider additional management approach if the other three were not acceptable enough. Thus, NWMO studied and created a fourth management approach after it had undertaken an comparison of the benefits, risks and costs of each management approach: Adaptive Phased Management. This approach was intended to enable the implementers to accept any technological advancement or changes even in the middle of the implementation of the plan. The Canadian PSE case well shows that technological R and D are deeply connected with social acceptance. Even though the developments and technological advancement are carried out by the scientists and experts, but it is important to collect the public opinion by involving them to the decision-making process in order to achieve objective validity on the R and D programs. Moreover, in an effort to ensure the principles such as fairness, public health and safety, security, and adoptability, NWMO tried to make those abstract ideas more specific and help the public understand the meaning of each concept more in detail. Also, they utilized a variety of communication methods from face-to-face meeting to e-dialogue to encourage people to participate in the program as much as possible. Given the fact that Korea

  2. Division of nuclear liabilities between different license holders and owners - 59214

    Lindskog, Staffan; Sjoeblom, Rolf

    2012-01-01

    Sweden was one of the first six countries to build and operate a nuclear power reactor. Thus, there exists a corresponding legacy in terms of liabilities for decommissioning and waste management of the historic facilities. Compliance with the Polluter Pays Principle (PPP) and its corollary on equity between generations implies that plans for decommissioning must be made and funds set aside for its execution. The need for precision in the cost estimates often governs the timing of the technical planning. Cost estimates are treacherous since cost raisers may be identified and evaluated only after considerable efforts have been made. Further complications and challenges arise as a result of changes that take place between construction and decommissioning of facilities in terms of the entities involved as owners, operators, license holders, Authorities and financiers. From this perspective, the present paper summarizes the general legislation as well as the legislation that applies particularly to nuclear activities. It also summarizes the relation between the nuclear decommissioning fund system and financial reporting. Three examples are provided that wholly or partially fall under the Studsvik act (that specifically covers old facilities): - The Aagesta nuclear power plant; - The Ranstad uranium mining and beneficiation facility; - The Neutron Research Laboratory at Studsvik; The findings include the following: - It is important that the legislation be clear as to what is included and not. - The rationale for the legislation should also be clear and well communicated. - Old agreements can be significant for the assessment of liabilities, even in cases where a party may no longer exist. - Support for assessment of when activities are continuing or not (which may have a strong significance for the liability) can be found in court cases on chemically contaminated soil. - Analysis of facilities and the work carried out at different times can be very helpful in

  3. Canadian Public and Stake holder Engagement Approach to a Spent Nuclear Fuel Management

    Hwang, Yong Soo; Kim, Youn Ok; Whang, Joo Ho

    2008-01-01

    After Canada has struggled with a radioactive waste problem over for 20 years, the Canadian government finally found out that its approach by far has been lack of social acceptance, and needed a program such as public and stake holder engagement (PSE) which involves the public in decision-making process. Therefore, the government made a special law, called Nuclear Fuel Waste Act (NFWA), to search for an appropriate nuclear waste management approach. NFWA laid out three possible approaches which were already prepared in advance by a nuclear expert group, and required Nuclear Waste Management Organization (NWMO) to be established to report a recommendation as to which of the proposed approaches should be adopted. However, NFWA allowed NWMO to consider additional management approach if the other three were not acceptable enough. Thus, NWMO studied and created a fourth management approach after it had undertaken an comparison of the benefits, risks and costs of each management approach: Adaptive Phased Management. This approach was intended to enable the implementers to accept any technological advancement or changes even in the middle of the implementation of the plan. The Canadian PSE case well shows that technological R and D are deeply connected with social acceptance. Even though the developments and technological advancement are carried out by the scientists and experts, but it is important to collect the public opinion by involving them to the decision-making process in order to achieve objective validity on the R and D programs. Moreover, in an effort to ensure the principles such as fairness, public health and safety, security, and adoptability, NWMO tried to make those abstract ideas more specific and help the public understand the meaning of each concept more in detail. Also, they utilized a variety of communication methods from face-to-face meeting to e-dialogue to encourage people to participate in the program as much as possible. Given the fact that Korea

  4. Application of subsize specimens in nuclear plant life extension

    Rosinski, S.T.; Kumar, A.S.; Cannon, N.S.; Hamilton, M.L.

    1993-01-01

    The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missouri-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full-size samples. The program involves the impact testing of unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials, unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) will be tested. The correlation methodology is based on the partitioning of the USE into crack initiation and crack propagation energies. To accomplish this partition, both precracked and notched-only specimens will be used. Whereas the USE of notched-only specimens is the sum of both crack initiation and crack propagation energies, the USE of precracked specimens reflects only the crack propagation component. The difference in the USE of the two types of specimens represents a measure of the crack initiation energy. Normalizing the values of the crack initiation energy to the fracture volume of the sample produces similar values for the full-, half-, and third-size specimens. In addition, the ratios of the USE and the crack propagation energy are also in agreement for full-, half-, and third-size specimens. These two observations will be used to predict the USE of full-size specimens based on subsize USE data. This paper provides details of the program and presents results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full-, half-, and third-size A533 Grade B Charpy V-notch specimens

  5. 46 CFR 57.06-4 - Production testing specimen requirements.

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-4 Production testing specimen requirements. (a) For test... 46 Shipping 2 2010-10-01 2010-10-01 false Production testing specimen requirements. 57.06-4... to welding shall not throw the finished test plate out of line by an angle of over 5°. (c) Where the...

  6. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B.

    2015-01-01

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer

  7. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer.

  8. Design Analysis of the Mixed Mode Bending Sandwich Specimen

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    A design analysis of the mixed mode bending (MMB) sandwich specimen for face–core interface fracture characterization is presented. An analysis of the competing failure modes in the foam cored sandwich specimens is performed in order to achieve face–core debond fracture prior to other failure modes...... for the chosen geometries and mixed mode loading conditions....

  9. Blood specimen labelling errors: Implications for nephrology nursing practice.

    Duteau, Jennifer

    2014-01-01

    Patient safety is the foundation of high-quality health care, as recognized both nationally and worldwide. Patient blood specimen identification is critical in ensuring the delivery of safe and appropriate care. The practice of nephrology nursing involves frequent patient blood specimen withdrawals to treat and monitor kidney disease. A critical review of the literature reveals that incorrect patient identification is one of the major causes of blood specimen labelling errors. Misidentified samples create a serious risk to patient safety leading to multiple specimen withdrawals, delay in diagnosis, misdiagnosis, incorrect treatment, transfusion reactions, increased length of stay and other negative patient outcomes. Barcode technology has been identified as a preferred method for positive patient identification leading to a definitive decrease in blood specimen labelling errors by as much as 83% (Askeland, et al., 2008). The use of a root cause analysis followed by an action plan is one approach to decreasing the occurrence of blood specimen labelling errors. This article will present a review of the evidence-based literature surrounding blood specimen labelling errors, followed by author recommendations for completing a root cause analysis and action plan. A failure modes and effects analysis (FMEA) will be presented as one method to determine root cause, followed by the Ottawa Model of Research Use (OMRU) as a framework for implementation of strategies to reduce blood specimen labelling errors.

  10. On a specimen of Lumbricus terrestris, L. with bifurcated tail

    Horst, R.

    1886-01-01

    In the last number of the »Annals and Magazine of Nat. History” (Dec. 1885), I find a notice of Prof. Jeffrey Bell about two Lumbrici with bifid hinder ends, one specimen belonging to L. terrestris, the other to L. foetidus; moreover he mentions a specimen, presenting a similar remarquable

  11. Thermal Cycling of Uranium Dioxide - Tungsten Cermet Fuel Specimens

    Gripshover, P.J.; Peterson, J.H.

    1969-12-08

    In phase I tungsten clad cermet fuel specimens were thermal cycled, to study the effects of fuel loading, fuel particle size, stablized fuel, duplex coatings, and fabrication techniques on dimensional stability during thermal cycling. In phase II the best combination of the factors studies in phase I were combined in one specimen for evaluation.

  12. Development of adjustable head holder couch in H and H cancer radiation therapy

    Sim, Jae Goo; Song, Ki Won; Kim, Jin Man; Park, Myoung Hwan [Dept. of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2014-06-15

    In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was 0.4±0.8 mm, 0.8±0.4 mm, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was 0.2±0.8 mm, 1.2±0.4 mm, 2.0±0.4 mm. After adjusting position was X,Y,Z axis was 0.2±0.4, 0.4±0.5 mm, 0.4±0.5 mm

  13. Development of adjustable head holder couch in H and H cancer radiation therapy

    Sim, Jae Goo; Song, Ki Won; Kim, Jin Man; Park, Myoung Hwan

    2014-01-01

    In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was 0.4±0.8 mm, 0.8±0.4 mm, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was 0.2±0.8 mm, 1.2±0.4 mm, 2.0±0.4 mm. After adjusting position was X,Y,Z axis was 0.2±0.4, 0.4±0.5 mm, 0.4±0.5 mm

  14. Characterization of YBaCuO films deposited by the sputtering method using a temple-bell-type substrate holder

    Kajikawa, H.; Fukumoto, Y.; Shibutani, K.; Hayashi, S.; Ishibashi, K.; Inoue, K.

    1992-01-01

    The as-grown YBaCuO films deposited by the off-axis sputtering method using a temple-bell type substrate holder showed a good crystalline quality with a minimum yield value x min of 0.9 MeV He ions of 3.8%. The post-annealing degraded the crystalline quality to increase x min up to 11.8%, though it improved both the T c and J c . It was supposed that the degradation was caused by the re-arrangement of oxygen atoms. (orig.)

  15. Compact design of a transmission electron microscope-scanning tunneling microscope holder with three-dimensional coarse motion

    Svensson, K.; Jompol, Y.; Olin, H.; Olsson, E.

    2003-01-01

    A scanning tunneling microscope (STM) with a compact, three-dimensional, inertial slider design is presented. Inertial sliding of the STM tip, in three dimensions, enables coarse motion and scanning using only one piezoelectric tube. Using the same electronics both for scanning and inertial sliding, step lengths of less than 5% of the piezo range were achieved. The compact design, less than 1 cm3 in volume, ensures a low mechanical noise level and enables us to fit the STM into the sample holder of a transmission electron microscope (TEM), while maintaining atomic scale resolution in both STM and TEM imaging

  16. Dose assessment for CEGB users of the Kodak type 2 film used in the NRPB/AERE holder

    Hill, M.J.

    1980-07-01

    Some work, complementary to that of the National Radiological Protection Board (NRPB) and the Atomic Energy Research Establishment (AERE), has been done at Berkeley Nuclear Laboratories (BNL) on the response of the Kodak Type 2 film in the NRPB/AERE holder. Initial results indicate that the combination forms a satisfactory dosemeter. Comparison between the BNL and NRPB results shows differences which appear to be due to the fact that the angle of incidence was 90 0 for the former and 35 0 for the latter. Some conclusions are drawn on dosimetry but in general, for CEGB users, no substantial changes from existing procedures are required. (author)

  17. Solo Intracorporeal Esophagojejunostomy Reconstruction Using a Laparoscopic Scope Holder in Single-Port Laparoscopic Total Gastrectomy for Early Gastric Cancer.

    Ahn, Sang-Hoon; Son, Sang-Yong; Jung, Do Hyun; Park, Young Suk; Shin, Dong Joon; Park, Do Joong; Kim, Hyung-Ho

    2015-06-01

    Single-incision laparoscopic total gastrectomy for gastric cancer has recently been reported by Seoul National University Bundang Hospital. However, this is not a popular procedure primarily because of the technical difficulties involved in achieving consistent intracorporeal esophagojejunostomy. At Seoul National University Bundang Hospital, we recently introduced a simple, easy-to-use, low-profile laparoscopic manual scope holder that enables the maintenance of a stable field of view, the most demanding condition in single-port gastrectomy. In this technical report, we describe in detail the world's first solo single-incision laparoscopic total gastrectomy with D1+ lymph node dissection and intracorporeal esophagojejunostomy for proximal early gastric cancer.

  18. Free at Last: Rejecting Equal Sovereignty and Restoring the Constitutional Right to Vote: Shelby County v. Holder

    Guinier, C. Lani; Blacksher, James

    2014-01-01

    The "equal sovereignty" principle the Supreme Court majority relied on in Shelby County v. Holder to strike down the coverage formula in Section 4 of the Voting Rights Act is rooted in the jurisprudence of slavery. In the infamous 1857 case of Dred Scott v. Sandford, Chief Justice Roger Taney held that black Americans, slave or free, were not members of the sovereign people and could never be "citizens" within the meaning of the Constitution. Otherwise, he said, blacks would be entitled to al...

  19. A novel feedback control system – Controlling the material flow in deep drawing using distributed blank-holder force

    Endelt, Benny Ørtoft; Tommerup, Søren; Danckert, Joachim

    2013-01-01

    The performance of a feedback control system is often limited by the quality of the model on which it is based, and often the controller design is based on trial and error due to insufficient modeling capabilities. A framework is proposed where the controller design is based on classical state...... on a deep drawing operation where the objective was to control material flow throughout the part using only spatial information regarding flange draw-in. The control system controls both the magnitude and distribution of the blank-holder force. The methodology proved stable and flexible with respect...

  20. The Market for Ph.D. Holders in Greece: Probit and Multinomial Logit Analysis of their Employment Status

    Joan Daouli; Eirini Konstantina Nikolatou

    2015-01-01

    The objective of this paper is to investigate the factors influencing the probability that a Ph.D. holder in Greece will work in the academic sector, as well as the probability of his or her choosing employment in various sectors of industry and occupational categories. Probit/multinomial logit models are employed using the 2001 Census data. The empirical results indicate that being young, married, having a Ph.D. in Natural Sciences and/or in Engineering, granted by a Greek university, increa...

  1. Enzymatic detection of formalin-fixed museum specimens for DNA analysis and enzymatic maceration of formalin-fixed specimens

    Sørensen, Margrethe; Redsted Rasmussen, Arne; Simonsen, Kim Pilkjær

    2016-01-01

    % ethanol. The method was subsequently tested on wild-living preserved specimens and an archived specimen. The protease enzyme used was SavinaseH 16 L, Type EX from Novozymes A/S. The enzymatic screening test demands only simple laboratory equipment. The method is useful for natural history collections...

  2. Fracture toughness measurements with subsize disk compact specimens

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods are necessary to facilitate the fracture toughness testing of small disk compact specimens of irradiated candidate materials for first-wall fusion applications. New methods have been developed for both the unloading compliance and potential drop techniques of monitoring crack growth. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hot cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimen 12.7 mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  3. Fracture toughness measurements with subsize disk compact specimens

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (12.5 mm diam by 4.6 mm thick). Both unloading compliance and potential drop methods have been used to monitor crack extension during the J-integral resistance (J-R) curve testing. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hat cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimens 12.7-mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  4. Synchrotron radiation microprobe quantitative analysis method for biomedical specimens

    Xu Qing; Shao Hanru

    1994-01-01

    Relative changes of trace elemental content in biomedical specimens are obtained easily by means of synchrotron radiation X-ray fluorescence microprobe analysis (SXRFM). However, the accurate assignment of concentration on a g/g basis is difficult. Because it is necessary to know both the trace elemental content and the specimen mass in the irradiated volume simultaneously. the specimen mass is a function of the spatial position and can not be weighed. It is possible to measure the specimen mass indirectly by measuring the intensity of Compton scattered peak for normal XRF analysis using a X-ray tube with Mo anode, if the matrix was consisted of light elements and the specimen was a thin sample. The Compton peak is not presented in fluorescence spectrum for white light SXRFM analysis. The continuous background in the spectrum was resulted from the Compton scattering with a linear polarization X-ray source. Biomedical specimens for SXRFM analysis, for example biological section and human hair, are always a thin sample for high energy X-ray, and they consist of H,C,N and O etc. light elements, which implies a linear relationship between the specimen mass and the Compton scattering background in the high energy region of spectrum. By this way , it is possible to carry out measurement of concentration for SXRFM analysis

  5. Instrumented impact testing machine with reduced specimen oscillation effects

    Rintamaa, R.; Rahka, K.; Wallin, K.

    1984-07-01

    Owing to small and inexpensive specimens the Charpy impact test is widely used in quality control and alloy development. Limitations in power reactor survellance capsules it is also widely used for safety analysis purposes. Instrumenting the tup and computerizing data acquisition, makes dynamic fracture mechanics data measurement possible and convenient. However, the dynamic effects (inertia forces, specimen oscillations) in the impact test cause inaccuracies in the recorded load-time diagram and hence diminish the reliability of the calculated dynamic fracture mechanics parameters. To decrease inaccuracies a new pendulum type of instrumented impact test apparatus has been developed and constructed in the Metals Laboratory of the Technical Research Centre of Finland. This tester is based on a new principle involving inverted test geometry. The purpose of the geometry inversion is to reduce inertia load and specimen oscillation effects. Further, the new impact tester has some other novel features: e.g. the available initia impact energy is about double compared to the conventional standard (300 J) impact tester allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. Also, the rotation asix in the three point bending is nearly stationary making COD-measurements possible. An experimental test series is described in which the inertia effects and specimen oscillations are compared in the conventional and new impact tester utilizing Charpy V-notch specimens. Comparison of the two test geometries is also made with the aid of an analytical model using finite element method (FEM) analysis. (author)

  6. Final Report: Posttest Analysis of Omega II Optical Specimens

    Newlander, C D; Fisher, J H

    2007-01-01

    Preliminary posttest analyses have been completed on optical specimens exposed during the Omega II test series conducted on 14 July 2006. The Omega Facility, located at the Laboratory for Laser Energetics (LLE) at the University of Rochester was used to produce X-ray environments through the interaction of intense pulsed laser radiation upon germanium-loaded silica aerogels. The optical specimen testing was supported by GH Systems through experiment design, pre- and post-test analyses, specimen acquisition, and overall technical experience. The test specimens were fabricated and characterized by Surface Optics Corporation (SOC), San Diego, CA and were simple protected gold coatings on silica substrates. Six test specimens were exposed, five filtered with thin beryllium foil filters, and one unfiltered which was exposed directly to the raw environment. The experimental objectives were: (1) demonstrate that tests of optical specimens could be performed at the Omega facility; (2) evaluate the use and survivability of beryllium foil filters as a function of thickness; (3) obtain damage data on optical specimens which ranged from no damage to damage; (4) correlate existing thermal response models with the damage data; (5) evaluate the use of the direct raw environment upon the specimen response and the ability/desirability to conduct sensitive optical specimen tests using the raw environment; and (6) initiate the development of a protocol for performing optical coatings/mirror tests. This report documents the activities performed by GH Systems in evaluating and using the environments provided by LLNL, the PUFFTFT analyses performed using those environments, and the calculated results compared to the observed and measured posttest data

  7. Post-deformation examination of specimens subjected to SCC testing

    Gussev, Maxim N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Busby, Jeremy T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Leonard, Keith J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    This report details the results of post-radiation and post-deformation characterizations performed during FY 2015–FY 2016 on a subset of specimens that had previously been irradiated at high displacement per atom (dpa) damage doses. The specimens, made of commercial austenitic stainless steels and alloys, were subjected to stress-corrosion cracking tests (constant extension rate testing and crack growth testing) at the University of Michigan under conditions typical of nuclear power plants. After testing, the specimens were returned to Oak Ridge National Laboratory (ORNL) for further analysis and evaluation.

  8. The effect of specimen and flaw dimensions on fracture toughness

    Nevalainen, M.J.

    1997-06-01

    The effect of the specimen size and geometry on fracture toughness has been investigated both by experimental tests and computational analyses. The methods for constraint description, namely T-stress, Q-parameter and Small-Scale Yielding Correction (SSYC) have been compared and applied for various geometries. A statistical treatment for the specimen thickness effect on cleavage fracture toughness has been investigated. Elliptical surface cracks were compared with straight-thickness cracks and a method for crack shape correction was presented. Based on the results, the differences in apparent fracture toughness values obtained from various specimen configurations can be better understood and taken into account

  9. Fabrication and testing of prestressed composite rotor blade spar specimens

    Gleich, D.

    1974-01-01

    Prestressed composite spar specimens were fabricated and evaluated by crack propagation and ballistic penetration tests. The crack propagation tests on flawed specimens showed that the prestressed composite spar construction significantly suppresses crack growth. Damage from three high velocity 30 caliber projectile hits was confined to three small holes in the ballistic test specimen. No fragmentation or crack propagation was observed indicating good ballistic damage resistance. Rotor attachment approaches and improved structural performance configurations were identified. Design theory was verified by tests. The prestressed composite spar configuration consisted of a compressively prestressed high strength ARDEFORM 301 stainless steel liner overwrapped with pretensioned S-994 fiberglass.

  10. Fracture mechanics characterisation of medium-size adhesive joint specimens

    Sørensen, Bent F.; Jacobsen, T.K.

    2004-01-01

    Medium-size specimens (glass-fibre beams bonded together by an adhesive layer were tested in four point bending to determine their load carrying capacity. Specimens having different thickness were tested. Except for onespecimen, the cracking occurred as cracking...... along the adhesive layer; initially cracking occurred along the adhesive/laminate interface, but after some crack extension the cracking took place inside the laminate (for one specimen the later part of thecracking occurred unstably along the adhesive/ laminate interface). Crack bridging by fibres...

  11. The effect of alumina particles on the microstructural and mechanical properties of copper foams fabricated by space-holder method

    Salvo, C.; Aguilar, C.; Lascano, S.; Pérez, L.; López, M.; Mangalaraja, R. V.

    2018-05-01

    The copper foam is an interesting field of research because of its several advantages as an engineering material. Powder metallurgy presents an alternative route to obtain a porous structure with high strength to weight ratio and functional properties. The viability of processing copper foam separately with two different space-holders such as ammonium hydrogen carbonate (NH4HCO3) and sodium chloride (NaCl) of 50 vol% was studied. The green compacts obtained under 200 MPa were sintered at different cycles for the complete removal of space-holder. The sintered foams were characterized by optical microscopy (OM), scanning electron microscopy (SEM) and uniaxial testing machine (UTM) to study their structural features and compressive strength, respectively. The results showed that NaCl particles were the best alternative to obtain a porous structure, hence two different sizes (1 and 0.01 μm) of alumina (Al2O3) particles with 2, 4 and 6 vol% were used to fabricate copper foams. As a result, a bimodal structure consisting of macro and micropores with a highly interconnected porosity was achieved. In addition, the smaller size alumina particles promoted a higher density of pores, however, the compressive strength was reduced for the higher volume fraction of alumina particles.

  12. Highly porous open cell Ti-foam using NaCl as temporary space holder through powder metallurgy route

    Jha, Nidhi; Mondal, D.P.; Dutta Majumdar, J.; Badkul, Anshul; Jha, A.K.; Khare, A.K.

    2013-01-01

    Highlights: ► NaCl crystals has been used as space holder. ► Variation of NaCl:Ti ratio varies porosity (65–80%). ► NaCl is cubic but the cells are spherical. ► Two types of pores: micro and macro pores are obtained. ► Foams are suitable for bones scaffolds and engineering applications. - Abstract: Open cell Titanium-foam (Ti-foam) with varying porosities (65–80%) was prepared using sodium chloride (NaCl) particles as space holder through powder metallurgy route. In order to ensure sufficient handling strength in cold compacted pallets, 2 wt.% polyvinyl alcohol (PVA) solutions (5 wt.% PVA in water) was mixed with the mixture of Ti and NaCl powders prior to cold compaction. After sintering, NaCl salt was removed by dissolving it in hot water. Detailed Energy dispersive X-ray (EDX) analysis and X-ray diffraction studies of the prepared Ti-foams were conducted to examine any physical and chemical changes in the phase constituents. The micro-architectural characteristics, density vis-a-vis porosity, and compressive deformation behavior of the synthesized foams were evaluated to examine their suitability as biomaterial and engineering applications

  13. ARCTOS: a relational database relating specimens, specimen-based science, and archival documentation

    Jarrell, Gordon H.; Ramotnik, Cindy A.; McDonald, D.L.

    2010-01-01

    Data are preserved when they are perpetually discoverable, but even in the Information Age, discovery of legacy data appropriate to particular investigations is uncertain. Secure Internet storage is necessary but insufficient. Data can be discovered only when they are adequately described, and visibility increases markedly if the data are related to other data that are receiving usage. Such relationships can be built within (1) the framework of a relational database, or (1) they can be built among separate resources, within the framework of the Internet. Evolving primarily around biological collections, Arctos is a database that does both of these tasks. It includes data structures for a diversity of specimen attributes, essentially all collection-management tasks, plus literature citations, project descriptions, etc. As a centralized collaboration of several university museums, Arctos is an ideal environment for capitalizing on the many relationships that often exist between items in separate collections. Arctos is related to NIH’s DNA-sequence repository (GenBank) with record-to-record reciprocal linkages, and it serves data to several discipline-specific web portals, including the Global Biodiversity Information Network (GBIF). The University of Alaska Museum’s paleontological collection is Arctos’s recent extension beyond the constraints of neontology. With about 1.3 million cataloged items, additional collections are being added each year.

  14. Old Plants, New Tricks: Phenological Research Using Herbarium Specimens.

    Willis, Charles G; Ellwood, Elizabeth R; Primack, Richard B; Davis, Charles C; Pearson, Katelin D; Gallinat, Amanda S; Yost, Jenn M; Nelson, Gil; Mazer, Susan J; Rossington, Natalie L; Sparks, Tim H; Soltis, Pamela S

    2017-07-01

    The timing of phenological events, such as leaf-out and flowering, strongly influence plant success and their study is vital to understanding how plants will respond to climate change. Phenological research, however, is often limited by the temporal, geographic, or phylogenetic scope of available data. Hundreds of millions of plant specimens in herbaria worldwide offer a potential solution to this problem, especially as digitization efforts drastically improve access to collections. Herbarium specimens represent snapshots of phenological events and have been reliably used to characterize phenological responses to climate. We review the current state of herbarium-based phenological research, identify potential biases and limitations in the collection, digitization, and interpretation of specimen data, and discuss future opportunities for phenological investigations using herbarium specimens. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Validity of fracture toughness determined with small bend specimens

    Wallin, K.; Rintamaa, R.; Valo, M.

    1994-02-01

    This report considers the validity of fracture toughness estimates obtained with small bend specimens in relation to fracture toughness estimates obtained with large specimens. The study is based upon the analysis and comparison of actual test results. The results prove the validity of the fracture toughness determined based upon small bend specimens, especially when the results are only used to determine the fracture toughness transition temperature T o . In this case the possible error is typically less than 5 deg C and at most 10 deg C. It can be concluded that small bend specimens are very suitable for the estimation of fracture toughness in the case of brittle fracture, provided the results are corrected for statistical size effects. (orig.). (20 refs., 17 figs.)

  16. Description of Specimens in the Marine Mammal Osteology Reference Collection

    National Oceanic and Atmospheric Administration, Department of Commerce — The NMFS Alaska Fisheries Science Center National Marine Mammal Laboratory (NMML) Marine Mammal Osteology Collection consists of approximately 2500 specimens (skulls...

  17. Elemental microanalysis of botanical specimens using the Melbourne Proton Microprobe

    Mazzolini, A.P.J.; Legge, G.J.F.

    1978-01-01

    A proton microprobe has been used to obtain the distribution of elements of various botanical specimens. This paper presents preliminary results obtained by the irradiation of certain organs of the wheat plant

  18. Replacement/Refurbishment of JSC/NASA POD Specimens

    Castner, Willard L.

    2010-01-01

    The NASA Special NDE certification process requires demonstration of NDE capability by test per NASA-STD-5009. This test is performed with fatigue cracked specimens containing very small cracks. The certification test results are usually based on binomial statistics and must meet a 90/95 Probability of Detection (POD). The assumption is that fatigue cracks are tightly closed, difficult to detect, and inspectors and processes passing such a test are well qualified for inspecting NASA fracture critical hardware. The JSC NDE laboratory has what may be the largest inventory that exists of such fatigue cracked NDE demonstration specimens. These specimens were produced by the hundreds in the late 1980s and early 1990s. None have been produced since that time and the condition and usability of the specimens are questionable.

  19. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  20. Molecular markers: Implications for cytopathology and specimen collection.

    VanderLaan, Paul A

    2015-08-01

    Cytologic specimens obtained through minimally invasive biopsy techniques are increasingly being used as principle diagnostic specimens for tumors arising in multiple sites. The number and scope of ancillary tests performed on these specimens have grown substantially over the past decade, including many molecular markers that not only can aid in formulating accurate and specific diagnoses but also can provide prognostic or therapeutic information to help direct clinical decisions. Thus, the cytopathologist needs to ensure that adequate material is collected and appropriately processed for the study of relevant molecular markers, many of which are specific to tumor site. This brief review covers considerations for effective cytologic specimen collection and processing to ensure diagnostic and testing success. In addition, a general overview is provided of molecular markers pertinent to tumors from a variety of sites. The recognition of these established and emerging molecular markers by cytopathologists is an important step toward realizing the promise of personalized medicine. © 2015 American Cancer Society.

  1. Examination of the fatigue life under combined loading of specimens

    Fojtík F.

    2008-11-01

    Full Text Available This contribution describes experimental results under combined loading of specimens manufactured from common construction steel 11523. Specimens were gradually loaded by amplitude of the torque, then by combination of torque and tension prestress. The last set of specimens was loaded in combination of torque and inner overpressure. To obtain the required input values the stress-strain analysis of specimens by finite element method in software Ansys was performed within the last experiment. For evaluation of the results the Fuxa's criterion was applied. The performed experiments and their results embody a good agreement with bellow mentioned conjugated strength criterion. The experiments were performed on reconstructed testing machine equipped by pressure chamber.

  2. 46 CFR 54.05-5 - Toughness test specimens.

    2010-10-01

    ... shown in Figure 4 of the specification. Special attention is drawn to the fact that the Charpy Keyhole....090-inch. In preparing weld specimens for dropweight testing, weld reinforcement shall be ground flush...

  3. Influence of specimen size on the creep of rock salt

    Senseny, P.E.

    1982-01-01

    Triaxial compression creep data for Avery Island dome salt are analyzed to determine the influence of specimen size on creep deformation. Laboratory experiments were performed on 50- and 100-mm-diameter specimens in the temperature range from 25 to 200 0 C and the axial stress difference range from 2.5 to 31.0 MPa. The strain-vs-time data from each test are divided into transient and steady-state components. Results of statistical analysis of these data show that transient creep of the small specimens is a stronger function of stress, temperature, and time than is transient creep of the larger specimens. Analysis of the steady-state data show no size effect, however. 14 references, 7 figures, 3 tables

  4. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  5. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    Sørensen, Bent F.; Jørgensen, K.; Jacobsen, T.K.

    2004-01-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratiobetween the two applied moments, the full mode...... glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre bridging, eventually reaching asteady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement....

  6. Biaxial Testing of 2195 Aluminum Lithium Alloy Using Cruciform Specimens

    Johnston, W. M.; Pollock, W. D.; Dawicke, D. S.; Wagner, John A. (Technical Monitor)

    2002-01-01

    A cruciform biaxial test specimen was used to test the effect of biaxial load on the yield of aluminum-lithium alloy 2195. Fifteen cruciform specimens were tested from 2 thicknesses of 2195-T8 plate, 0.45 in. and 1.75 in. These results were compared to the results from uniaxial tensile tests of the same alloy, and cruciform biaxial tests of aluminum alloy 2219-T87.

  7. Progress Report on Alloy 617 Notched Specimen Testing

    McMurtrey, Michael David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wright, Richard Neil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lillo, Thomas Martin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Creep behavior of Alloy 617 has been extensively characterized to support the development of a draft Code Case to qualify Alloy 617 in Section III division 5 of the ASME Boiler and Pressure Vessel Code. This will allow use of Alloy 617 in construction of nuclear reactor components at elevated temperatures and longer periods of time (up to 950°C and 100,000 hours). Prior to actual use, additional concerns not considered in the ASME code need to be addressed. Code Cases are based largely on uniaxial testing of smooth gage specimens. In service conditions, components will generally be under multi axial loading. There is also the concern of the behavior at discontinuities, such as threaded components. To address the concerns of multi axial creep behavior and at geometric discontinuities, notched specimens have been designed to create conditions representative of the states that service components experience. Two general notch geometries have been used for these series of tests: U notch and V notch specimens. The notches produce a tri axial stress state, though not uniform across the specimen. Characterization of the creep behavior of the U notch specimens and the creep rupture behavior of the V notch specimens provides a good approximation of the behavior expected of actual components. Preliminary testing and analysis have been completed and are reported in this document. This includes results from V notch specimens tested at 900°C and 800°C. Failure occurred in the smooth gage section of the specimen rather than at the root of the notch, though some damage was present at the root of the notch, where initial stress was highest. This indicates notch strengthening behavior in this material at these temperatures.

  8. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions

    Schmachtenberg, C.; Engelken, F.; Fischer, T.; Bick, U.; Poellinger, A.; Fallenberg, E.M. [Charite, Berlin (Germany). Radiology

    2012-07-15

    Purpose: Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. Materials and Methods: After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Results: Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Conclusion: Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. (orig.)

  9. Thinning of specimens for examination under the electron microscope

    Franks, J.

    1982-01-01

    Heretofore specimens have been thinned to penetration for examination by electron microscopy techniques, by ion erosion techniques. A more rapid technique is disclosed employing a beam or beams comprised solely of neutral particles. In tests carried out using this technique the sputtering rate from a sample specimen has been shown to be several percentages greater using a neutral source than from an ion source with the same flux density. (author)

  10. Improved PID control for triaxial testing liquefied specimen

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    Using a frictionless triaxial apparatus, sand specimens can be tested at relatively high axial strains, even while liquefying. However, liquefying specimens have extremely nonlinear stiffness, thus standard PID control does not perform well. To maintain control over applied loads, the PID...... controller was modified to adapt to disturbed soil states. The proposed methods expand the scope of testing towards options which are otherwise inaccessible by triaxial testing....

  11. Design and construction of OGL-1 Specimen Transfer System

    Nakamura, Kunio; Saruta, Tohru; Nabeya, Hideaki; Nakagaki, Shogo; Nishizaki, Tadashi.

    1977-11-01

    OGL-1 is the first high temperature gas in-pile loop in Japan, which is installed in JMTR of Oarai Research Establishment, JAERI. As the JMTR is the PWR type, specimens must be set in the loop with a remote control system ''OGL-1 Specimen Transfer System'' because of the needs for moisture prevention and radiation shielding. Described in this report are design philosophy, loop development, problems in construction, inspection and operation. (auth.)

  12. Detecting Rickettsia parkeri Infection from Eschar Swab Specimens

    2013-05-01

    Detecting Rickettsia parkeri Infection from Eschar Swab Specimens Todd Myers, Tahaniyat Lalani, Mike Dent, Ju Jiang, Patrick L. Daly, Jason D...Maguire, and Allen L. Richards The typical clinical presentation of several spotted fever group Rickettsia infections includes eschars. Clinical...diagnosis by using an eschar swab specimen from patients infected with Rickettsia parkeri. Until 2004, all confirmed cases of tick-borne spotted

  13. Influence of thermal conditioning media on Charpy specimen test temperature

    Nanstad, R.K.; Swain, R.L.; Berggren, R.G.

    1989-01-01

    The Charpy V-notch (CVN) impact test is used extensively for determining the toughness of structural materials. Research programs in many technologies concerned with structural integrity perform such testing to obtain Charpy energy vs temperature curves. American Society for Testing and Materials Method E 23 includes rather strict requirements regarding determination and control of specimen test temperature. It specifies minimum soaking times dependent on the use of liquids or gases as the medium for thermally conditioning the specimen. The method also requires that impact of the specimen occur within 5 s removal from the conditioning medium. It does not, however, provide guidance regarding choice of conditioning media. This investigation was primarily conducted to investigate the changes in specimen temperature which occur when water is used for thermal conditioning. A standard CVN impact specimen of low-alloy steel was instrumented with surface-mounted and embedded thermocouples. Dependent on the media used, the specimen was heated or cooled to selected temperatures in the range -100 to 100 degree C using cold nitrogen gas, heated air, acetone and dry ice, methanol and dry ice, heated oil, or heated water. After temperature stabilization, the specimen was removed from the conditioning medium while the temperatures were recorded four times per second from all thermocouples using a data acquisition system and a computer. The results show that evaporative cooling causes significant changes in the specimen temperatures when water is used for conditioning. Conditioning in the other media did not result in such significant changes. The results demonstrate that, even within the guidelines of E 23, significant test temperature changes can occur which may substantially affect the Charpy impact test results if water is used for temperature conditioning. 7 refs., 11 figs

  14. Special fracture mechanics specimens for multilayer plastic pipes testing

    Hutař, Pavel; Šestáková, Lucie; Knésl, Zdeněk; Nezbedová, E.; Náhlík, Luboš

    2009-01-01

    Roč. 28, č. 8 (2009), s. 785-792 ISSN 0142-9418 R&D Projects: GA ČR GA106/09/0279; GA ČR GC101/09/J027 Institutional research plan: CEZ:AV0Z20410507 Keywords : Multilayer plastic pipes * C-type specimen * K-calibration * Fracture toughness * Slow crack growth * Non-homogenous specimens Subject RIV: JL - Material s Fatigue, Friction Mechanics Impact factor: 1.667, year: 2009

  15. Failed PCR of Ganoderma type specimens affects nomenclature.

    Paterson, R R M; Lima, N

    2015-06-01

    The nomenclature of Ganoderma used as a Chinese medicine is debated. A group of researchers could not amplify the DNA of type specimens and concluded the DNA was degraded irreparably. New topotypes were used as the type specimens which was premature. The use of internal amplification controls is recommended to determine if other factors were involved as alternative explanations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions.

    Schmachtenberg, C; Engelken, F; Fischer, T; Bick, U; Poellinger, A; Fallenberg, E M

    2012-07-01

    Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions

    Schmachtenberg, C.; Engelken, F.; Fischer, T.; Bick, U.; Poellinger, A.; Fallenberg, E.M.

    2012-01-01

    Purpose: Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. Materials and Methods: After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Results: Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Conclusion: Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. (orig.)

  18. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Yamamoto Sohei

    2010-10-01

    Full Text Available Abstract Background Accurate evaluation of human epidermal growth factor receptor type-2 (HER2 status based on core needle biopsy (CNB specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. Methods A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH, the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. Results In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71 for 3 × 3 categories (0-1+ versus 2+ versus 3+ and 90% (κ = 0.80 for 2 × 2 categories (0-2+ versus 3+. These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77 for 3 × 3 categories and 92% (κ = 0.88 for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77 for 3 × 3 categories, and 94% (κ = 0.83 for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of

  19. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Tsuda, Hitoshi; Kurosumi, Masafumi; Umemura, Shinobu; Yamamoto, Sohei; Kobayashi, Takayuki; Osamura, Robert Yoshiyuki

    2010-01-01

    Accurate evaluation of human epidermal growth factor receptor type-2 (HER2) status based on core needle biopsy (CNB) specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC) and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH), the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71) for 3 × 3 categories (0-1+ versus 2+ versus 3+) and 90% (κ = 0.80) for 2 × 2 categories (0-2+ versus 3+). These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77) for 3 × 3 categories and 92% (κ = 0.88) for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77) for 3 × 3 categories, and 94% (κ = 0.83) for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of 2+ differed among specimens processed at

  20. Reliability of 46,XX results on miscarriage specimens: a review of 1,222 first-trimester miscarriage specimens.

    Lathi, Ruth B; Gustin, Stephanie L F; Keller, Jennifer; Maisenbacher, Melissa K; Sigurjonsson, Styrmir; Tao, Rosina; Demko, Zach

    2014-01-01

    To examine the rate of maternal contamination in miscarriage specimens. Retrospective review of 1,222 miscarriage specimens submitted for chromosome testing with detection of maternal cell contamination (MCC). Referral centers requesting genetic testing of miscarriage specimens at a single reference laboratory. Women with pregnancy loss who desire complete chromosome analysis of the pregnancy tissue. Analysis of miscarriage specimens using single-nucleotide polymorphism (SNP) microarray technology with bioinformatics program to detect maternal cell contamination. Chromosome content of miscarriages and incidence of 46,XX results due to MCC. Of the 1,222 samples analyzed, 592 had numeric chromosomal abnormalities, and 630 were normal 46,XX or 46,XY (456 and 187, respectively). In 269 of the 46,XX specimens, MCC with no embryonic component was found. With the exclusion of maternal 46,XX results, the chromosomal abnormality rate increased from 48% to 62%, and the ratio for XX to XY results dropped from 2.6 to 1.0. Over half of the normal 46,XX results in miscarriage specimens were due to MCC. The use of SNPs in MCC testing allows for precise identification of chromosomal abnormalities in miscarriage as well as MCC, improving the accuracy of products of conception testing. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. AGC-2 Specimen Post Irradiation Data Package Report

    Windes, William Enoch [Idaho National Lab. (INL), Idaho Falls, ID (United States); Swank, W. David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rohrbaugh, David T. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cottle, David L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between

  2. Cross-Cultural Comparative Analysis of Lay and Stake holder Reasoning about Fusion Energy in Spain and the UK

    Prades, A; Horlick-Jones, T; Oltra, C; Navajas, J

    2009-07-01

    This report presents the results of a cross-cultural comparative analysis of two corpora of data from Spain and the UK on lay and stake holders understanding and reasoning about fusion energy. The very same novel methodological approach was applied in Spain and the UK to promote a learning and deliberative process about fusion energy. A brief description of the method is included first, followed by the description of the two corpora of data. Next the main Spanish findings data are discussed in the light of the UK data and then vice versa (in other words, we first interrogate the UK corpus of data to look for resonances or places of tension with the Spanish findings, and then the other way around). Then we present the results of evaluating the Spanish and UK group-based processes as engagement exercises. Finally, the key conclusions of this cross-cultural data analysis are summarized. (Author) 40 refs.

  3. Low conductive support for thermal insulation of a sample holder of a variable temperature scanning tunneling microscope.

    Hanzelka, Pavel; Vonka, Jakub; Musilova, Vera

    2013-08-01

    We have designed a supporting system to fix a sample holder of a scanning tunneling microscope in an UHV chamber at room temperature. The microscope will operate down to a temperature of 20 K. Low thermal conductance, high mechanical stiffness, and small dimensions are the main features of the supporting system. Three sets of four glass balls placed in vertices of a tetrahedron are used for thermal insulation based on small contact areas between the glass balls. We have analyzed the thermal conductivity of the contacts between the balls mutually and between a ball and a metallic plate while the results have been applied to the entire support. The calculation based on a simple model of the setup has been verified with some experimental measurements. In comparison with other feasible supporting structures, the designed support has the lowest thermal conductance.

  4. Ecological Diversity of Soil Fauna as Ecosystem Engineers in Small-Holder Cocoa Plantation in South Konawe

    Laode Muhammad Harjoni Kilowasid

    2012-05-01

    Full Text Available Taxa diversity within soil fauna functional groups can affected ecosystem functioning such as ecosystem engineers,which influence decomposition and nutrient cycling. The objective of this study is to describe ecological diversityvariation within soil fauna as ecosystem engineers in soil ecosystem of cocoa (Theobroma cacao L. plantation.Sampling was conducted during one year period from five different ages of plantation. Soil fauna removed from soilcore using hand sorting methods. A total of 39 genera of soil fauna as ecosystem engineers were found during thesestudies. Thirty five genera belong to the group of Formicidae (ants, three genera of Isoptera (termites, and onegenera of Oligochaeta (earthworms. Ecological diversity variation within ecosystem engineers was detected withSimpson indices for dominance and evenness. The highest diversity of ecosystem engineers was in the young ageof plantation. This study reinforces the importance biotic interaction which contributed to the distribution andabundance within soil fauna community as ecosystem engineers in small-holder cocoa plantation.

  5. Cross-Cultural Comparative Analysis of Lay and Stake holder Reasoning about Fusion Energy in Spain and the UK

    Prades, A.; Horlick-Jones, T.; Oltra, C.; Navajas, J.

    2009-01-01

    This report presents the results of a cross-cultural comparative analysis of two corpora of data from Spain and the UK on lay and stake holders understanding and reasoning about fusion energy. The very same novel methodological approach was applied in Spain and the UK to promote a learning and deliberative process about fusion energy. A brief description of the method is included first, followed by the description of the two corpora of data. Next the main Spanish findings data are discussed in the light of the UK data and then vice versa (in other words, we first interrogate the UK corpus of data to look for resonances or places of tension with the Spanish findings, and then the other way around). Then we present the results of evaluating the Spanish and UK group-based processes as engagement exercises. Finally, the key conclusions of this cross-cultural data analysis are summarized. (Author) 40 refs.

  6. Small specimen technique for assessing mechanical properties of metallic components

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E., E-mail: rmlobo@ipen.br, E-mail: morcelliae@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  7. Single specimen fracture toughness determination procedure using instrumented impact test

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  8. An acceleration test for stress corrosion cracking using humped specimen

    Kamaya, Masayuki; Fukumura, Takuya; Totsuka, Nobuo

    2003-01-01

    By using the humped specimen, which is processed by the humped die, in the slow strain rate technique (SSRT) test, fracture facet due to stress corrosion cracking (SCC) can be observed in relatively short duration. Although the cold work and concentrated stress and strain caused by the characteristic shape of the specimen accelerate the SCC, to date these acceleration effects have not been examined quantitatively. In the present study, the acceleration effects of the humped specimen were examined through experiments and finite element analyses (FEA). The experiments investigated the SCC of alloy 600 in the primary water environment of a pressurized water reactor. SSRT tests were conducted using two kinds of humped specimen: one was annealed after hump processing in order to eliminate the cold work, and the other was hump processed after the annealing treatment. The work ratio caused by the hump processing and stress/strain conditions during SSRT test were evaluated by FEA. It was found that maximum work ratio of 30% is introduced by the hump processing and that the distribution of the work ratio is not uniform. Furthermore, the work ratio is influenced by the friction between the specimen and dies as well as by the shape of dies. It was revealed that not only the cold work but also the concentrated stress and strain during SSRT test accelerate the crack initiation and growth of the SCC. (author)

  9. Demonstration of Laser Cutting System for Tube Specimen

    Jin, Y. G.; Kim, G. S.; Heo, G. S.; Baik, S. J.; Kim, H. M.; Ahn, S. B. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated fuel cladding and components interrupted the applying the electric current during the processing. However, it was found that the mechanical testing data of the irradiated specimens with removal of oxide layer was less reliable than the specimens with oxide layer . The laser cutting system using Nd:YAG with fiber optic beam delivery has great potential in material processing applications of the irradiated fuel cladding and components due to non-contact process. Thus, the oxide layer doesn't interrupt the fabrication process during the laser cutting system. In the present study, the laser cutting system was designed to fabricate the mechanical testing specimens from the unirradiated fuel cladding with and without oxide. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of unirradiated specimens. The effect of surface oxide layer was also investigated for machining process of the zirlo fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer. Based on the feasibility studies and demonstration, the design of the laser cutting machine for fully or partially automatic and remotely operable system will be proposed and made.

  10. Small specimen technique for assessing mechanical properties of metallic components

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E.

    2017-01-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  11. Monolithic integration of nanoscale tensile specimens and MEMS structures

    Yilmaz, Mehmet; Kysar, Jeffrey W

    2013-01-01

    Nanoscale materials often have stochastic material properties due to a random distribution of material defects and an insufficient number of defects to ensure a consistent average mechanical response. Current methods to measure the mechanical properties employ MEMS-based actuators. The nanoscale specimens are typically mounted manually onto the load platform, so the boundary conditions have random variations, complicating the experimental measurement of the intrinsic stochasticity of the material properties. Here we show methods for monolithic integration of a nanoscale specimen co-fabricated with the loading platform. The nanoscale specimen is gold with dimensions of ∼40 nm thickness, 350 ± 50 nm width, and 7 μm length and the loading platform is an interdigitated electrode electrostatic actuator. The experiment is performed in a scanning electron microscope and digital image correlation is employed to measure displacements to determine stress and strain. The ultimate tensile strength of the nanocrystalline nanoscale specimen approaches 1 GPa, consistent with measurements made by other nanometer scale sample characterization methods on other material samples at the nanometer scale, as well as gold samples at the nanometer scale. The batch-compatible microfabrication method can be used to create nominally identical nanoscale specimens and boundary conditions for a broad range of materials. (paper)

  12. Improving the productivity of imported dairy cattle on small-holder farms in Morocco through supplementation with fish silage blocks

    Guerouali, A.

    1999-01-01

    The present study was designed to identify problems that lower the productivity of imported dairy cattle in Morocco. For this purpose, a comprehensive survey was carried out on 8 small-holder farms over a period of two years. Analysis of the data collected indicated that in most of the herds reproductive performance was adequate (calving intervals ranging from 338 ± 11 to 420 ± 31 and services to conception ranging from 1.14 ± 0.13 to 1.91 ± 0.3), but the animals had difficulty in meeting the nutrient requirements for milk production. Although some farmers provided supplements to their animals they were either expensive or not available at the required time. One possible way of alleviating the problem was the introduction of a fish by-product into the dairy cattle ration. Two experiments were conducted, one at the Institute experimental farm and the other at a private farm selected for the survey. In both experiments, fish silage blocks were incorporated into the ration of dairy cattle in replacement of an equal amount of the most commonly used supplements. The introduction of fish silage blocks in the ration did not affect their intake or body condition. In addition, the yield and quality of the milk were maintained. This substitution allowed the farmer to utilize by-products from the fish industry which are readily available and less costly than most conventional supplementary feeds. It is concluded, that the proposed utilization of fish silage blocks will reduce the production costs and improve the economic efficiency of the small-holder farms. (author)

  13. Friction Compensation in the Upsetting of Cylindrical Test Specimens

    Christiansen, Peter; Martins, P. A. F.; Bay, Niels Oluf

    2016-01-01

    This manuscript presents a combined numerical andexperimental methodology for determining the stress-straincurve of metallic materials from the measurements of forceand displacement obtained in the axial compression of cylindrical test specimens with friction between the specimens and the platens....... The methodology is based on minimizing the errorbetween the average surface pressure obtained from the experimental measurements of the force and displacement and thatobtained from the slab method of analysis of metal plasticity.Three different friction models based on Coulomb friction, the constant friction...... model or combined friction models are utilized .Experimental results obtained from cylindrical and Rastegaev test specimens with different lubricants combined with the experimental determination of friction by means of ring compression tests allows compensating the effect of friction...

  14. Thermal expansion of epoxy-fiberglass composite specimens

    McElroy, D.L.; Weaver, F.J.; Bridgman, C.

    1986-01-01

    The thermal expansion behavior of three epoxy-fiberglass composite specimens was measured from 20 to 120 0 C (70 to 250 0 F) using a fused quartz push-rod dilatometer. Billets produced by vacuum impregnating layers of two types of fiberglass cloth with an epoxy resin were core-drilled to produce cylindrical specimens. These were used to study expansion perpendicular and parallel to the fiberglass layers. The dilatometer is held at a preselected temperature until steady-state is indicated by stable length and temperature data. Before testing the composite specimens, a reliability check of the dilatometer was performed using a copper secondary standard. This indicated thermal expansion coefficient (α) values within +-2% of expected values from 20 to 200 0 C

  15. Extraction of ultrashort DNA molecules from herbarium specimens.

    Gutaker, Rafal M; Reiter, Ella; Furtwängler, Anja; Schuenemann, Verena J; Burbano, Hernán A

    2017-02-01

    DNA extracted from herbarium specimens is highly fragmented; therefore, it is crucial to use extraction protocols that retrieve short DNA molecules. Improvements in extraction and DNA library preparation protocols for animal remains have allowed efficient retrieval of molecules shorter than 50 bp. Here, we applied these improvements to DNA extraction protocols for herbarium specimens and evaluated extraction performance by shotgun sequencing, which allows an accurate estimation of the distribution of DNA fragment lengths. Extraction with N-phenacylthiazolium bromide (PTB) buffer decreased median fragment length by 35% when compared with cetyl-trimethyl ammonium bromide (CTAB); modifying the binding conditions of DNA to silica allowed for an additional decrease of 10%. We did not observe a further decrease in length for single-stranded DNA (ssDNA) versus double-stranded DNA (dsDNA) library preparation methods. Our protocol enables the retrieval of ultrashort molecules from herbarium specimens, which will help to unlock the genetic information stored in herbaria.

  16. Strip specimen tests for pipeline materials and girth welds

    Mohr, William C. [Edison Welding Institute (EWI), Columbus, Ohio (United States)

    2009-07-01

    Strip specimen testing of pipeline materials has been widely applied as a method of getting data relevant to the performance of pipelines under axial direction loading. Comparisons of strip specimen against smaller standard tests (round tensile bar, fracture toughness specimens, polished round bars) and against full-scale or large-scale testing will be explored. Data from early-generation pipe welds from the 1920's to the 1940's to the most recent materials for offshore reeled pipe will be used for examples. Strip samples can provide full thickness information to take account of varying material properties or imperfection distribution through the thickness. Strip samples can also accommodate measurement of effects of the original surface finish or weld surface shape. Strip samples have more design flexibility than standard tests, but must be designed to limit stress concentrations and effects of local bending. (author)

  17. Measurement of deformation field in CT specimen using laser speckle

    Jeon, Moon Chang; Kang, Ki Ju

    2001-01-01

    To obtain A 2 experimentally in the J-A 2 theory, deformation field on the lateral surface of a CT specimen was to be determined using laser speckle method. The crack growth was measured using direct current potential drop method and most procedure of experimental and data reduction was performed according to ASTM Standard E1737-96. Laser speckle images during crack propagation were monitored by two CCD cameras to cancel the effect of rotation and translation of the specimen. An algorithm to pursue displacement of a point from each image was developed and successfully used to measure A 2 continuously as the crack tip was propagated. The effects of specimen thickness on J-R curve and A 2 were explored

  18. JR-curves of wide plates and CT25 specimens

    Aurich, D.; Wobst, K.; Krafka, H.

    1987-01-01

    In connection with the problem of the applicability of the characteristic specimen date - i.e. the initiation and stable crack propagation under maximal loads, together with the elastic-plastic material behaviour - to that of actual components, spot-check type beside tests were conducted using wide-plate central crack, central notch (CCT, CNT) and double external crack (DECT) samples. The material in question was an StE 460 steel. A comparison between the determined values shows that the assessed pressure vessel behaviour differs extensively to the values derived from the CCT and CNT specimens. The corresponding results obtained from the CT25 and DECT specimens vary only slightly in the region of interest and correspond to real vessel values. (orig./DG) [de

  19. The effect of specimen and flaw dimensions on fracture toughness

    Nevalainen, M.J. [VTT Manufacturing Technology, Espoo (Finland)

    1997-06-01

    The effect of the specimen size and geometry on fracture toughness has been investigated both by experimental tests and computational analyses. The methods for constraint description, namely T-stress, Q-parameter and Small-Scale Yielding Correction (SSYC) have been compared and applied for various geometries. A statistical treatment for the specimen thickness effect on cleavage fracture toughness has been investigated. Elliptical surface cracks were compared with straight-thickness cracks and a method for crack shape correction was presented. Based on the results, the differences in apparent fracture toughness values obtained from various specimen configurations can be better understood and taken into account. 64 refs. The thesis includes also four previous publications by author.

  20. Strain Measurement System Developed for Biaxially Loaded Cruciform Specimens

    Krause, David L.

    2000-01-01

    A new extensometer system developed at the NASA Glenn Research Center at Lewis Field measures test area strains along two orthogonal axes in flat cruciform specimens. This system incorporates standard axial contact extensometers to provide a cost-effective high-precision instrument. The device was validated for use by extensive testing of a stainless steel specimen, with specimen temperatures ranging from room temperature to 1100 F. In-plane loading conditions included several static biaxial load ratios, plus cyclic loadings of various waveform shapes, frequencies, magnitudes, and durations. The extensometer system measurements were compared with strain gauge data at room temperature and with calculated strain values for elevated-temperature measurements. All testing was performed in house in Glenn's Benchmark Test Facility in-plane biaxial load frame.

  1. Impregnation of soft biological specimens with thermosetting resins and elastomers.

    von Hagens, G

    1979-06-01

    A new method for impregnation of biological specimens with thermosetting resins and elastomers is described. The method has the advantage that the original relief of the surface is retained. The impregnation is carried out by utilizing the difference between the high vapor tension of the intermedium (e.g., methylene chloride) and the low vapor tension of the solution to be polymerized. After impregnation, the specimen is subject to polymerization conditions without surrounding embedding material. The optical and mechanical properties can be selected by proper choice from various kinds of resins and different procedures, for example, by complete or incomplete impregnation. Acrylic resins, polyester resins, epoxy resins, polyurethanes and silicone rubber have been found suitable for the method. Excellent results have been obtained using transparent silicone rubber since after treatment the specimens are still flexible and resilient, and have retained their natural appearance.

  2. An analysis of forensic entomological specimens by Universiti Kebangsaan Malaysia.

    Syamsa, R A; Ahmad, F M S; Marwi, M A; Zuha, R M; Omar, B

    2010-09-01

    This study reviews forensic entomological specimens analysed by the Department of Parasitology & Medical Entomology, Universiti Kebangsaan Malaysia for the year 2004. A total of 10 cases (6 males and 4 females) were observed for the entomological specimens. Various types of death scenes were obtained including indoor and outdoor area such as bushes field, rubbish dumping site, and aquatic areas. Identified fly species collected from the death sites were blow flies, Chrysomya megacephala, Chrysomya rufifacies and Lucilia cuprina and unknown sarcophagid larvae, with Ch. megacephala being the most common species found in the ecologically varied death scene habitats. The post-mortem interval (PMI) estimation ranged from one to five days, based on the entomological specimens collected.

  3. Cerenkov and radioluminescence imaging of brain tumor specimens during neurosurgery

    Spinelli, Antonello Enrico; Schiariti, Marco P.; Grana, Chiara M.; Ferrari, Mahila; Cremonesi, Marta; Boschi, Federico

    2016-05-01

    We presented the first example of Cerenkov luminescence imaging (CLI) and radioluminescence imaging (RLI) of human tumor specimens. A patient with a brain meningioma localized in the left parietal region was injected with 166 MBq of Y90-DOTATOC the day before neurosurgery. The specimens of the tumor removed during surgery were imaged using both CLI and RLI using an optical imager prototype developed in our laboratory. The system is based on a cooled electron multiplied charge coupled device coupled with an f/0.95 17-mm C-mount lens. We showed for the first time the possibility of obtaining CLI and RLI images of fresh human brain tumor specimens removed during neurosurgery.

  4. Fracture toughness measurements with subsize disk compact specimens

    Alexander, D.J.

    1994-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (1.25 mm diam by 4.6 mm thick). Specimens of European type 316L austenitic stainless steel were irradiated to damage levels of about 3 dpa at nominal irradiation temperatures of either 90 or 250 C and tested over a temperature range from 20 to 250 C. Results show that irradiation to this dose level at these temperatures reduces the fracture toughness but the toughness remains quite high. The toughness decreases as the test temperature increases. Irradiation at 250 C is more damaging than at 90 C, causing larger decreases in the fracture toughness. The testing shows that it is possible to generate useful fracture toughness data with a small disk compact specimens

  5. Catalogue of test specimens for non-destructive examination

    1985-05-01

    One of the key elements in assuring the integrity of reactor primary circuits is the availability of trustworthy non-destructive methods for detecting dangerous defects that may be present. Various approaches to making such examinations are being developed, including the use of ultrasonic and radiographic techniques. To demonstrate their capability and reliability, they must be tested on steel specimens reproducing the various types of faults which may arise in real primary circuit vessels and piping. Such specimens are costly to fabricate. It is therefore clearly desirable that existing specimens should be made accessible to as many organisations as possible for testing. This catalogue contains detailed Information on forty-odd deliberately flawed plates, blocks, vessels, etc. which have been produced in OECD countries, along with the name of a contact person to whom inquiries should be directed in each case

  6. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  7. Gleason Score Correlation Between Prostate Biopsy and Radical Prostatectomy Specimens

    Erdem Öztürk

    2018-04-01

    Full Text Available Objective: Prostate cancer is the most common malignancy in men and the second cause of cancer-related mortality. Prostate biopsy and the Gleason score guide treatment decisions in prostate cancer. Several studies have investigated the correlation between biopsy scores and radical prostatectomy specimen scores. We also evaluated the correlation of Gleason scores of these specimens in our patient series. Materials and Methods: We retrospectively reviewed the data of 468 men who were diagnosed with prostate cancer and underwent radical prostatectomy between 2008 and 2017. Patients’ age, prostate-specific antigen levels at diagnosis, and prostate biopsy and radical prostatectomy specimen Gleason scores were recorded. Upgrading and downgrading were defined as increase or decrease of Gleason score of radical prostate specimen compared to Gleason score of prostate biopsy. Results: A total of 442 men diagnosed with prostate cancer were included in the study. The mean age of the patients was 62.62±6.26 years (44-84 years and mean prostate specific antigen level was 9.01±6.84 ng/mL (1.09-49 ng/mL. Prostate biopsy Gleason score was 7 in 27 (6.1% men. Radical prostatectomy specimen Gleason score was 7 in 62 (14% men. Gleason correlation was highest in the 240 patients (71.6% with score <7 and was lowest in the 31 (38.75% patients with score =7. Conclusion: This study demonstrated that the discordance rate between Gleason scores of prostate biopsy and radical prostatectomy specimens was 35.7%.

  8. Imaging of concrete specimens using inverse synthetic aperture radar

    Rhim, Hong C.; Buyukozturk, Oral

    2000-01-01

    Radar Measurement results of laboratory size concrete specimens are presented in this paper. The purpose of this research work is to study various aspects of the radar method in an effort to develop an improved radar system for nondestructive testing of concrete structures. The radar system used for the study is an Inverse Synthetic Aperture Radar (ISAR), which is capable of transmitting microwaves at three different frequency ranges of 2-3.4, 3.4-5.8, and 8-12 GHz. Radar measurement setup is such that the radar is locates 14.4 m away from a concrete target to satisfy a far-field criterion. The concrete target is rotated for 20 degrees during the measurements for the generation of two-dimensional (cross-range) imagery. Concrete targets used for the measurements have the dimensions of 305 mm (width)x305 mm (height)x92 mm (thickness) with different inside configurations. Comparisons are made for dry and wet specimens, specimens with and without inclusions. Each specimen is made to model various situations that a concrete structure can have in reality. Results show that center frequency, frequency bandwidth, and polarization of the incident wave have different effects on identifying the thickness or inclusions inside concrete specimens. Results also suggest that a certain combination of measurement parameters is suitable for a specific application area. Thus, measurement parameters can be optimized for a specific problem. The findings are presented and discussed in details in the paper. Signal processing schemes implemented for imaging of the specimens are also discussed

  9. Dataset of herbarium specimens of threatened vascular plants in Catalonia.

    Nualart, Neus; Ibáñez, Neus; Luque, Pere; Pedrol, Joan; Vilar, Lluís; Guàrdia, Roser

    2017-01-01

    This data paper describes a specimens' dataset of the Catalonian threatened vascular plants conserved in five public Catalonian herbaria (BC, BCN, HGI, HBIL and MTTE). Catalonia is an administrative region of Spain that includes large autochthon plants diversity and 199 taxa with IUCN threatened categories (EX, EW, RE, CR, EN and VU). This dataset includes 1,618 records collected from 17 th century to nowadays. For each specimen, the species name, locality indication, collection date, collector, ecology and revision label are recorded. More than 94% of the taxa are represented in the herbaria, which evidence the paper of the botanical collections as an essential source of occurrence data.

  10. Centrifuge-operated specimen staining method and apparatus

    Clarke, Mark S. F. (Inventor); Feeback, Daniel L. (Inventor)

    1999-01-01

    A method of staining preselected, mounted specimens of either biological or nonbiological material enclosed within a staining chamber where the liquid staining reagents are applied and removed from the staining chamber using hypergravity as the propelling force. In the preferred embodiment, a spacecraft-operated centrifuge and method of diagnosing biological specimens while in orbit, characterized by hermetically sealing a shell assembly. The assembly contains slide stain apparatus with computer control therefor, the operative effect of which is to overcome microgravity, for example on board an International Space Station.

  11. Pseudolipomatosis in Endometrial Specimens Does Not Represent Uterine Perforation.

    Heller, Alexis

    2017-02-01

    Specimens of endometrial biopsies can sometimes present with an artifact within blood, composed of optically clear vacuoles mimicking adipose tissue, pseudolipomatosis. This artifact can be mistaken for adipose tissue and lead to an overdiagnosis of uterine perforation. We describe the case of pseudolipomatosis seen within the evacuated products of conception from a missed abortion. Areas of vacuolization in the blood clot mimicked adipose tissue. However, the vacuoles varied in size and did not contain adipocytes. Familiarity with this artifact will lead to avoidance of overdiagnosis of adipose tissue and uterine perforation in curettage specimens.

  12. Occurrence of biflavones in leaves of Caesalpinia pyramidalis specimens

    Marcus V. Bahia

    2010-01-01

    Full Text Available The chloroform partition of methanol extract of leaves of Caesalpinia pyramidalis was submitted to different chromatographic procedures which afforded besides agathisflavone and taxifolin, the minor biflavones loniflavone, amentoflavone, 5'- hydroxyamentoflavone and podocarpusflavone A. The structures of the compounds were established on the basis of NMR and MS data analysis. Besides, the content of biflavones of different specimens of C. pyramidalis, which are collected in different habitats of the Brazilian semi-arid region, was determinated by LC-APCI-MS analysis. These analysis demonstrated that only the specimens harvested in Bahia state showed collectively the presence of agathisflavone, amentoflavone, sequoiaflavone and podocarpusflavone A.

  13. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens.

    Guan, Yaoyao; Gravitt, Patti E; Howard, Roslyn; Eby, Yolanda J; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E

    2013-04-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p=0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    Soerensen, B.F.; Joergensen, K.; Oestergaard, R.C. [Risoe National Lab., Materials Dept., Roskilde (Denmark); Jacobsen, T.K. [LM Glasfiber A/S, Lunderskov (Denmark)

    2004-03-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratio between the two applied moments, the full mode mixity range from pure mode I to pure mode II can be generated for the same specimen geometry. The specimen allows stable crack growth. In case of large scale crack bridging, mixed mode cohesive laws can be obtained by a J integral based approach. As a preliminary example, fracture of adhesive joints between two glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre cross over bridging, eventually reaching a steady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement. Cohesive stresses were determined by a J integral approach. The deducted shear stress was found to be relative high ({approx} = 20 MPa) in comparison with the normal stress ({approx} = 1 MPa). (au)

  15. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens

    Guan, YaoYao; Gravitt, Patti E.; Howard, Roslyn; Eby, Yolanda J.; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E.

    2016-01-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p = 0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. PMID:23370404

  16. A matter of focus: Power-holders feel more responsible after adopting a cognitive other-focus, rather than a self-focus

    Scholl, Annika; Sassenberg, Kai; Scheepers, Daan; Ellemers, Naomi|info:eu-repo/dai/nl/086631276; de Wit, Frank

    Social power implies responsibility. Yet, power-holders often follow only their own interests and overlook this responsibility. The present research illuminates how a previously adopted cognitive focus guides perceived responsibility when a person receives high (vs. low) power. In three experiments,

  17. 26 CFR 1.860E-1 - Treatment of taxable income of a residual interest holder in excess of daily accruals.

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Treatment of taxable income of a residual interest holder in excess of daily accruals. 1.860E-1 Section 1.860E-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment...

  18. Who Will Do Science? Trends, and Their Causes in Minority and Female Representation among Holders of Advanced Degrees in Science and Mathematics. A Special Report.

    Berryman, Sue E.

    This paper describes trends in and causes of minority and female representation among holders of advanced science and math degrees. The minority groups studied are Blacks, Hispanic Americans, American Indians, and Asian Americans, all of whom are compared with Whites. The degrees looked at include those in math, the computer sciences, physical…

  19. 17 CFR 270.18f-2 - Fair and equitable treatment for holders of each class or series of stock of series investment...

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Fair and equitable treatment for holders of each class or series of stock of series investment companies. 270.18f-2 Section 270.18f... or series of stock of series investment companies. (a) For purposes of this § 270.18f-2 a series...

  20. Determinants of the Job Satisfaction of PhD Holders: An Analysis by Gender, Employment Sector, and Type of Satisfaction in Spain

    Escardíbul, Josep-Oriol; Afcha, Sergio

    2017-01-01

    We analyze the determinants of job satisfaction of PhD holders in Spain. Specifically, we consider overall job satisfaction as well as basic and motivational satisfaction, following Herzberg's typology (based on Maslow's hierarchy of needs). Using representative data for Spain's PhD population--collected from the Spanish Survey on Human Resources…

  1. The Motivation and Identity Challenges for PhD Holders in the Transition to Science and Mathematics Teaching in Secondary Education: A Pilot Study

    Whannell, Robert; Allen, Bill

    2014-01-01

    Australian secondary education has endured a chronic shortage of qualified mathematics and science teachers for a number of years, particularly in rural and remote areas. A longitudinal research project examining the capacity for the holders of PhD level qualifications in mathematics and science to be utilised as one means of addressing this…

  2. Electron emission of cathode holder of vacuum diode of an intense electron-beam accelerator and its effect on the output voltage

    Xin-Bing Cheng

    2011-04-01

    Full Text Available The vacuum diode which is used to generate relativistic electron beams is one of the most important parts of a pulsed-power modulator. In this paper, the electron emission of cathode holder of a vacuum diode and its effect on the output voltage is investigated by experiments on an intense electron-beam accelerator with 180 ns full width at half maximum and 200–500 kV output voltage. First, the field emission is analyzed and the electric field of the vacuum chamber is calculated. Then, the flatness of the output voltage is discussed before and after adding an insulation plate when a water load is used. It is found that the electron emission at the edges of the cathode holder is the main reason to cause the change of the flatness. Last, a piece of polyester film is used as a target to further show the electron emission of the cathode holder. This analysis shows that decreasing the electron emission of the cathode holder in such a pulse power modulator could be a good way to improve the quality of the output voltage.

  3. Comparison of gross anatomy test scores using traditional specimens vs. QuickTime Virtual Reality animated specimens

    Maza, Paul Sadiri

    In recent years, technological advances such as computers have been employed in teaching gross anatomy at all levels of education, even in professional schools such as medical and veterinary medical colleges. Benefits of computer based instructional tools for gross anatomy include the convenience of not having to physically view or dissect a cadaver. Anatomy educators debate over the advantages versus the disadvantages of computer based resources for gross anatomy instruction. Many studies, case reports, and editorials argue for the increased use of computer based anatomy educational tools, while others discuss the necessity of dissection for various reasons important in learning anatomy, such as a three-dimensional physical view of the specimen, physical handling of tissues, interactions with fellow students during dissection, and differences between specific specimens. While many articles deal with gross anatomy education using computers, there seems to be a lack of studies investigating the use of computer based resources as an assessment tool for gross anatomy, specifically using the Apple application QuickTime Virtual Reality (QTVR). This study investigated the use of QTVR movie modules to assess if using computer based QTVR movie module assessments were equal in quality to actual physical specimen examinations. A gross anatomy course in the College of Veterinary Medicine at Cornell University was used as a source of anatomy students and gross anatomy examinations. Two groups were compared, one group taking gross anatomy examinations in a traditional manner, by viewing actual physical specimens and answering questions based on those specimens. The other group took the same examinations using the same specimens, but the specimens were viewed as simulated three-dimensional objects in a QTVR movie module. Sample group means for the assessments were compared. A survey was also administered asking students' perceptions of quality and user-friendliness of the QTVR

  4. On three specimens of Lagenorhynchus albirostris Gray, 1846 (Mammalia, Cetacea)

    Bree, van P.J.H.; Nijssen, H.

    1964-01-01

    Recently the Zoological Museum in Amsterdam came into possession of three specimens of the White-beaked Dolphin, Lagenorhynchus albirostris. As data on this species are rather scarce, it may be useful to publish a few notes on these animals. The first dolphin, a female, was caught in the North Sea

  5. Finite strain analyses of deformations in polymer specimens

    Tvergaard, Viggo

    2016-01-01

    Analyses of the stress and strain state in test specimens or structural components made of polymer are discussed. This includes the Izod impact test, based on full 3D transient analyses. Also a long thin polymer tube under internal pressure has been studied, where instabilities develop, such as b...

  6. The effect of specimen thickness on the experimental and finite ...

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    as a fracture parameter and the J-CTOD relation for the determination of critical ... fracture behaviour of EDD (0·06%C) steel sheets with CT specimens and using ... On the other hand, in the predominantly plane stress region, if the toughness value ..... (iii) Hardness measurement – The plastic zone size and shape is also ...

  7. 50 CFR 31.12 - Sale of wildlife specimens.

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Sale of wildlife specimens. 31.12 Section 31.12 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM WILDLIFE SPECIES MANAGEMENT Terms and Conditions of Wildlife...

  8. Biology, Ordinary and Higher Grades, Syllabuses and Specimen Question Papers.

    Scottish Certificate of Education Examination Board, Edinburgh.

    Included is the prescribed syllabus in biology for the Scottish Certificate of Education. In two separate sections, the syllabus topics and specimen questions for final examinations are explained. This syllabus is intended to present biology as knowledge about living organisms without making the conventional division between plants and animals.…

  9. Sample handling of clinical specimens for ultratrace element analysis

    Cornelis, R.

    1987-01-01

    Some simple logistics to an improved sample handling of clinical specimens are presented. This comprises clean room conditions, clean laboratory ware, ultra-pure reagents and good analytical practice. Sample handling procedures for blood, urine, soft tissues and pharmaceuticals are briefly discussed. (author) 26 refs

  10. Method of 10B determination in biological specimens

    Nikitina, R.G.; Frolova, E.I.

    1981-01-01

    The paper is concerned with the methods of 10 B determination in biological specimens (blood, skin and tissues of rats). On the basis of investigations conducted there have been proposed films based on cellulose triacetate with optimal characteristics in terms of their possible utilization as solid detectors to record α-particles and recoil nuclei. The conditions of film staining are also discussed

  11. Culturing Stool Specimens for Campylobacter spp., Pennsylvania, USA

    M’ikanatha, Nkuchia M.; Dettinger, Lisa A.; Perry, Amanda; Rogers, Paul; Reynolds, Stanley M.

    2012-01-01

    In 2010, we surveyed 176 clinical laboratories in Pennsylvania regarding stool specimen testing practices for enteropathogens, including Campylobacter spp. Most (96.3%) routinely test for Campylobacter spp. In 17 (15.7%), a stool antigen test is the sole method for diagnosis. We recommend that laboratory practice guidelines for Campylobacter spp. testing be developed. PMID:22377086

  12. Vacuum sealing and cooling as methods to preserve surgical specimens

    Kielsgaard Kristensen, Thomas; Engvad, Birte; Nielsen, Ole

    2011-01-01

    Recently, vacuum-based preservation of surgical specimens has been proposed as a safe alternative to formalin fixation at the surgical theater. The method seems feasible from a practical point of view, but no systematic study has examined the effect of vacuum sealing alone with respect to tissue...

  13. Evaluation of A-1 reactor heavy-water calandria specimens

    Brumovsky, M.

    1976-01-01

    Container chains with surveillance specimens were placed in two special channels of the core peripheral part to test changes in mechanical properties due to reactor operation of caisson tube material. The specimens were made from the caisson tube material and placed by eight pieces on the outer surface of the containers. The first removed specimens were tested for corrosion losses, tensile strength, and fractured surfaces were then assessed. The changes in strength properties were found to be similar in both base material and welded joints. The corrosion film on surveillance specimens did not practically affect strength properties nor ductility. It was found that the Al-Mg-Si alloy used for the heavy water vessel caisson tubes following stabilization annealing was fully stable at operating temperatures of up to 100 degC. Slio.ht changes in properties can be attributed to the effect of a high neutron dose. Thus, the high radiation and temperature stability of the alloy was confirmed. (O.K.)

  14. Specimen rotation system of the WSU TRIGA-fueled reactor

    Lovas, Thomas A.

    1976-01-01

    The specimen rotation system presently in use at the WSU reactor has been designed to provide maximum utilization of the irradiation capabilities achieved through use of TRIGA-type fuel. This paper describes the system with particular emphasis on characteristics which are advantageous to experimenters. (author)

  15. Ion source for thinning of specimen in transmission electron microscopy

    Hammer, K.; Rothe, R.

    1983-01-01

    Thinning of specimen for transmission electron microscopy is carried out by means of sputtering. Construction, design, and operation parameters of an ion source are presented. Because the plasma is produced by means of hollow cathode glow discharges, no special focusing system is used

  16. Polystyrene cryostat facilitates testing tensile specimens under liquid nitrogen

    Shogan, R. P.; Skalka, R. J.

    1967-01-01

    Lightweight cryostat made of expanded polystyrene reduces eccentricity in a tensile system being tested under liquid nitrogen. The cryostat is attached directly to the tensile system by a special seal, reducing misalignment effects due to cryostat weight, and facilitates viewing and loading of the specimens.

  17. 21 CFR 864.3250 - Specimen transport and storage container.

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Specimen transport and storage container. 864.3250 Section 864.3250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Pathology Instrumentation and Accessories § 864...

  18. MR evaluation of postmenopausal ovarian size. Comparison with surgical specimen

    Joja, Ikuo; Ishida, Kana; Matsushita, Toshi; Mimura, Seiichi; Yamaguchi, Takuya; Akagi, Noriaki; Miyagi, Yasunari; Hara, Takeshi; Kanazawa, Susumu

    2008-01-01

    We investigated ovarian size after menopause using magnetic resonance (MR) imaging and gross specimens obtained from patients with uterine cancer after menopause in whom normal ovaries were confirmed at the time of surgery. The relationships between size of ovarian long axis and age, the number of years since menopause, and age at menopause were statistically evaluated for 130 ovaries observed in short-axis T 2 -weighted MR images of the uterine corpus and in 147 ovarian gross specimens. No significant relationships were found between size of ovarian long axis and these 3 factors. When the sizes of the ovaries in MR images were compared with those in gross specimens, the latter were larger, with a statistically significant difference. Similarly, when the sizes of the ovaries observed or not observed in MR images were compared in gross specimens, the former were larger, with a statistically significant difference. These results indicate that the size of the ovarian long axis observed in MR images does not accurately reflect the true size of the long axis, but ovarian size strongly affects visualization of the ovaries in MR images after menopause. In addition, these results indicate that there are no significant relationships between ovarian size after menopause and age, the number of years since menopause, or age at menopause. (author)

  19. Fracture toughness evaluation of Eurofer'97 by testing small specimens

    Serrano, M.; Fernandez, P.; Lapena, J.

    2006-01-01

    The Eurofer'97 is the structural reference material that will be tested in the ITER modules. Its metallurgical properties have been well characterized during the last years. However, more investigations related with the fracture toughness of this material are necessary because this property is one of the most important to design structural components and to study their integrity assessment. In the case of structural materials for fusion reactor the small specimen technology (SSTT) are being actively developed to investigate the fracture toughness among other mechanical properties. The use of small specimens is due to the small available irradiation volume of IFMIF and also due to the high fluence expected in the fusion reactor. The aim of this paper is to determine the fracture toughness of the Eurofer'97 steel by testing small specimens of different geometry in the ductile to brittle transition region, with the application of the Master Curve methodology, and to evaluate this method to assess the decrease in fracture toughness due to neutron irradiation. The tests and data analysis have been performed following the Master Curve approach included in the ASTM Standard E1921-05. Specimen size effect and comparison of the fracture toughness results with data available in the literature are also considered. (author)

  20. Characterization of Two Historic Smallpox Specimens from a Czech Museum

    Pajer, P.; Dresler, J.; Kabickova, H.; Píša, L.; Aganov, P.; Fucik, K.; Elleder, Daniel; Hron, Tomáš; Kuželka, V.; Velemínský, P.; Klimentová, J.; Fučíková, A.; Pejchal, J.; Hrabáková, Rita; Beneš, V.; Rausch, T.; Dundr, P.; Pilin, A.; Čabala, R.; Hubálek, Martin; Stříbrný, J.; Antwerpen, M.H.; Meyer, H.

    2017-01-01

    Roč. 9, č. 8 (2017), č. článku 200. ISSN 1999-4915 Institutional support: RVO:68378050 ; RVO:67985904 ; RVO:61388963 Keywords : smallpox * variola virus * evolution * next generation suquencing * historic specimen * phylogeny Subject RIV: EB - Genetics ; Molecular Biology OBOR OECD: Virology; Virology (UZFG-Y); Virology (UOCHB-X) Impact factor: 3.465, year: 2016

  1. Breast surgical specimen radiographs: How reliable are they?

    Britton, P.D.; Sonoda, L.I.; Yamamoto, A.K.; Koo, B.; Soh, E.; Goud, A.

    2011-01-01

    Radiography of the excised surgical specimen following wire guided localisation of impalpable breast lesions is standard surgical practice. The aims of the study were to establish the reliability of the breast specimen radiograph (SR) in determining lesion excision and to determine whether the radiographic margin correlated with the histological margin. The clinical, imaging, SR and pathological details of 106 patients with a pre-operative diagnosis of breast cancer were retrospectively reviewed. The reliability of orientation was estimated and the appearance and distance from the mammographic abnormality to each radial margin were measured and correlated with surgical histological findings. The overall accuracy of the specimen radiograph in determining whether the mammographic lesion was present was 99%. The SR could be orientated 'very reliably' or 'reliably' in 80% of patients however in only 48% of patients did the closest margin on the SR correspond with the same nearest margin at final histology. A maximum measurement of 11 mm or more from the lesion to the specimen edge was associated with a 77% likelihood of having a clear final histological margin (taken as 5 mm or more) and if <11 mm a 58% chance of having involved final histological margins. There was however a wide overlap in the results with patients having an apparently wide SR margin but histologically involved margins and vice versa. The SR is reliable at determining whether the target lesion has been removed. The correlation of SR margin orientation and measurement with final histological measurement is however far less reliable.

  2. Pathologic diagnoses of appendectomy specimens: a 10-year review.

    A retrospective study was performed to see the pattern of histopathologic diagnoses in appendectomy specimens, their demographics, and the rate of negative appendectomy. Materials and methods: Records of resected appendices with a clinical diagnosis of acute appendicitis submitted to histopathology department of ...

  3. An electronic specimen collection protocol schema (eSCPS). Document architecture for specimen management and the exchange of specimen collection protocols between biobanking information systems.

    Eminaga, O; Semjonow, A; Oezguer, E; Herden, J; Akbarov, I; Tok, A; Engelmann, U; Wille, S

    2014-01-01

    The integrity of collection protocols in biobanking is essential for a high-quality sample preparation process. However, there is not currently a well-defined universal method for integrating collection protocols in the biobanking information system (BIMS). Therefore, an electronic schema of the collection protocol that is based on Extensible Markup Language (XML) is required to maintain the integrity and enable the exchange of collection protocols. The development and implementation of an electronic specimen collection protocol schema (eSCPS) was performed at two institutions (Muenster and Cologne) in three stages. First, we analyzed the infrastructure that was already established at both the biorepository and the hospital information systems of these institutions and determined the requirements for the sufficient preparation of specimens and documentation. Second, we designed an eSCPS according to these requirements. Finally, a prospective study was conducted to implement and evaluate the novel schema in the current BIMS. We designed an eSCPS that provides all of the relevant information about collection protocols. Ten electronic collection protocols were generated using the supplementary Protocol Editor tool, and these protocols were successfully implemented in the existing BIMS. Moreover, an electronic list of collection protocols for the current studies being performed at each institution was included, new collection protocols were added, and the existing protocols were redesigned to be modifiable. The documentation time was significantly reduced after implementing the eSCPS (5 ± 2 min vs. 7 ± 3 min; p = 0.0002). The eSCPS improves the integrity and facilitates the exchange of specimen collection protocols in the existing open-source BIMS.

  4. 21 CFR 866.2900 - Microbiological specimen collection and transport device.

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices... microbiological specimen collection and transport device is a specimen collecting chamber intended for medical...

  5. 3D volume reconstruction from serial breast specimen radiographs for mapping between histology and 3D whole specimen imaging

    Mertzanidou, T.; Hipwell, J.H.; Reis, S.; Hawkes, D.J.; Ehteshami Bejnordi, B.; Dalmis, M.U.; Vreemann, S.; Platel, B.; Laak, J.A. van der; Karssemeijer, N.; Hermsen, M.; Bult, P.; Mann, R.M.

    2017-01-01

    PURPOSE: In breast imaging, radiological in vivo images, such as x-ray mammography and magnetic resonance imaging (MRI), are used for tumor detection, diagnosis, and size determination. After excision, the specimen is typically sliced into slabs and a small subset is sampled. Histopathological

  6. SHOULD EVERY APPENDECECTOMY SPECIMEN BE SUBJECTED TO HISTOPATHOLOGICAL EXAMINATION? A RETROSPECTIVE STUDY OF HISTOLOGICAL FINDINGS IN APPENDICECTOMY SPECIMENS

    Shahanuma Shaik

    2017-12-01

    Full Text Available BACKGROUND Appendicitis is one of the commonest surgical emergencies with a lifetime risk of 7-8%. The appendicectomy specimens operated upon clinically-suspected appendicitis often appear normal on gross examination, but histopathological evaluation may reveal a diverse underlying pathology. Therefore, for accurate diagnosis, histopathological examination of all appendicectomy specimens is mandatory. MATERIALS AND METHODS A retrospective study of 175 appendicectomy cases operated over a period of two years. The clinical data and histopathological reports were reviewed and various histopathological findings are categorised. RESULTS Out of the total 175 appendicectomies, 155 emergency appendicectomy cases were included in the study, while 20 cases of incidental appendicectomy were excluded. The peak incidence was found in the 2nd and 3rd decades with male predominance. Among the 155 specimens, 96.8% had histological features of appendicitis and 1.9% were normal appendix. The unusual histopathological findings were Carcinoid tumour and Enterobius vermicularis. CONCLUSION The definitive diagnoses of appendicitis as well as the unusual incidental findings that were missed intraoperatively are established by histopathological examination. The study supports the histological examination of all resected appendicectomy specimens.

  7. Study of Biological Pigments by Single Specimen Derivative Spectrophotometry

    Goldstein, Jack M.

    1970-01-01

    The single specimen derivative (SSD) method provides an absolute absorption spectrum of a substance in the absence of a suitable reference. Both a reference and a measuring monochromatic beam pass through a single sample, and the specimen itself acts as its own reference. The two monochromatic beams maintain a fixed wavelength difference upon scanning, and the difference in absorbance of the two beams is determined. Thus, the resulting spectrum represents the first derivative of the conventional type absorption spectrum. Tissues and cell fractions have been examined at room and liquid N2 temperature and chromophoric molecules such as the mitochondrial cytochromes and blood pigments have been detectable in low concentrations. In the case of isolated cellular components, the observed effects of substrates and inhibitors confirm similar studies by conventional spectrophotometry. The extension of the SSD concept to the microscopic level has permitted the study of the tissue compartmentalization and function of cytochromes and other pigments within layered tissue. PMID:4392452

  8. Miniature specimen technology for postirradiation fatigue crack growth testing

    Mervyn, D.A.; Ermi, A.M.

    1979-01-01

    Current magnetic fusion reactor design concepts require that the fatigue behavior of candidate first wall materials be characterized. Fatigue crack growth may, in fact, be the design limiting factor in these cyclic reactor concepts given the inevitable presence of crack-like flaws in fabricated sheet structures. Miniature specimen technology has been developed to provide the large data base necessary to characterize irradiation effects on the fatigue crack growth behavior. An electrical potential method of measuring crack growth rates is employed on miniature center-cracked-tension specimens (1.27 cm x 2.54 cm x 0.061 cm). Results of a baseline study on 20% cold-worked 316 stainless steel, which was tested in an in-cell prototypic fatigue machine, are presented. The miniature fatigue machine is designed for low cost, on-line, real time testing of irradiated fusion candidate alloys. It will enable large scale characterization and development of candidate first wall alloys

  9. Design and Realization of Geographic Information System for Plant Specimens

    Zhenran Gao

    2016-03-01

    Full Text Available The thesis research work is based on adopting the combination of theory and technology research. For the unique characteristics of bambusoideae in yunnan province, analyses the characteristics, value and the present situation of resources of bambusoideae plant resources in yunnan province. According to the system requirements of the specimen of bambusoideae in Yunnan province, by Microsoft. Net framework platform, a collection of Web services and ASP.NET technology, based on the data of Microsoft SQL Server2008 and ADO.NET technology support, selecting desktop GIS Arc GIS platform (Arc GIS Desktop and server (Arc GIS Server as a system of GIS secondary development of GIS, and using developed tools of Microsoft Visual Studio 2010 Visual, Finally, the information system of plant specimen which based on GIS integration development of bambusoideae is finished .

  10. Measuring ERCC1 protein expression in cancer specimens

    Smith, David Hersi; Fiehn, Anne-Marie Kanstrup; Fogh, Louise

    2014-01-01

    Platinum chemotherapy remains part of standard therapies in the management of a variety of cancers. Severe side effects and a high degree of resistance to platinum drugs have led numerous researchers to search for predictive biomarkers, which could aid in identifying patients that are the most......, the specificity of antibody 4F9 was tested by immunoblotting, immunohistochemistry and immunofluorescence. Scoring guidelines to aid in the evaluation of ERCC1 tumor expression were developed and evaluated in archival formalin-fixed paraffin embedded colorectal cancer specimens. Antibody 4F9 was found...... to be specific by all methods applied and it was possible to evaluate the ERCC1 expression in the majority (85%) of colorectal cancer tumor specimens....

  11. The Effect of Holder Pasteurization on Nutrients and Biologically-Active Components in Donor Human Milk: A Review.

    Peila, Chiara; Moro, Guido E; Bertino, Enrico; Cavallarin, Laura; Giribaldi, Marzia; Giuliani, Francesca; Cresi, Francesco; Coscia, Alessandra

    2016-08-02

    When a mother's milk is unavailable, the best alternative is donor milk (DM). Milk delivered to Human Milk Banks should be pasteurized in order to inactivate the microbial agents that may be present. Currently, pasteurization, performed at 62.5 °C for 30 min (Holder Pasteurization, HoP), is recommended for this purpose in international guidelines. Several studies have been performed to investigate the effects of HoP on the properties of DM. The present paper has the aim of reviewing the published papers on this topic, and to provide a comparison of the reported variations of biologically-active DM components before and after HoP. This review was performed by searching the MEDLINE, EMBASE, CINHAL and Cochrane Library databases. Studies that clearly identified the HoP parameters and compared the same DM samples, before and after pasteurization, were focused on. A total of 44 articles satisfied the above criteria, and were therefore selected. The findings from the literature report variable results. A possible explanation for this may be the heterogeneity of the test protocols that were applied. Moreover, the present review spans more than five decades, and modern pasteurizers may be able to modify the degradation kinetics for heat-sensitive substances, compared to older ones. Overall, the data indicate that HoP affects several milk components, although it is difficult to quantify the degradation degree. However, clinical practices demonstrate that many beneficial properties of DM still persist after HoP.

  12. Urine specimen detection of zolpidem use in patients with pain.

    Mann, Lindsey M; Atayee, Rabia S; Best, Brookie M; Morello, Candis M; Ma, Joseph D

    2014-01-01

    This study examined zolpidem and concurrent opioid, benzodiazepine, other central nervous system (CNS) depressants, and alcohol use. Urine specimens were analyzed using liquid chromatography-mass spectrometry (LC-MS/MS). Specimens were tested for zolpidem (n = 71,919) and separated into a provider-reported medication list documenting (n = 5,257) or not documenting zolpidem use (n = 66,662). Zolpidem-positive specimens were further separated into reported and unreported use cohorts. The total number of zolpidem-positive specimens in the reported and unreported use cohorts was 3,391 and 3,190, respectively. Non-informed prescribers were 4.4% (3,190/71,919) among the general population and 48.5% (3,190/6,581) when only zolpidem users were considered. In the zolpidem user population, the most common concurrent opioids in both cohorts were hydrocodone and oxycodone. Alprazolam and clonazepam were higher in the unreported use cohort (P ≤ 0.05). The unreported use cohort also had a higher detection of zolpidem plus a benzodiazepine (49.7 vs. 46%; P ≤ 0.05), zolpidem plus an opioid and a benzodiazepine (40.8% vs. 37.4%; P ≤ 0.05) and zolpidem plus an opioid, a benzodiazepine, and an other CNS depressant (12.9 vs. 10.9%; P ≤ 0.05). Concurrent use of zolpidem, an opioid, a benzodiazepine and an other CNS depressant is prevalent in a pain patient population. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Specimen rejection in laboratory medicine: Necessary for patient safety?

    Dikmen, Zeliha Gunnur; Pinar, Asli; Akbiyik, Filiz

    2015-01-01

    The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas. The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected. Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics. We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety.

  14. Evaluation of miniature tension specimen fabrication techniques and performance

    Hamilton, M.L.; Blotter, M.A.; Edwards, D.J.

    1993-01-01

    The confident application of miniature tensile specimens requires adequate control over their fabrication and is facilitated by automated test and analysis techniques. Three fabrication processes -- punching, chemical milling, and electrical discharge machining (EDM) -- were recently evaluated, leading to the replacement of the previously used punching technique with a wire EDM technique. The automated data acquisition system was upgraded, and an interactive data analysis program was developed

  15. Behaviour of soil-cement specimens in unconfined dynamic compression

    Davies, J.; Fendukly, L. M.

    1994-06-01

    The response of the cement-stabilized red marl to dynamic loading in compression has been investigated over a range of cement contents and curing times. Specimens were subjected to different stress levels below unconfined compressive strength, at a frequency of 5 Hz, and a fatigue relationship for the material was developed. The value of resilient modulus was found to be greater than the modulus of elasticity for the same cement content and curing time.

  16. Innovations in macroscopic evaluation of pancreatic specimens and radiologic correlation

    Charikleia Triantopoulou

    2016-01-01

    Full Text Available The purpose of this study was to evaluate the feasibility of a novel dissection technique of surgical specimens in different cases of pancreatic tumors and provide a radiologic pathologic correlation. In our hospital, that is a referral center for pancreatic diseases, the macroscopic evaluation of the pancreatectomy specimens is performed by the pathologists using the axial slicing technique (instead of the traditional procedure with longitudinal opening of the main pancreatic and/or common bile duct and slicing along the plane defined by both ducts. The specimen is sliced in an axial plane that is perpendicular to the longitudinal axis of the descending duodenum. The procedure results in a large number of thin slices (3–4 mm. This plane is identical to that of CT or MRI and correlation between pathology and imaging is straightforward. We studied 70 cases of suspected different solid and cystic pancreatic tumors and we correlated the tumor size and location, the structure—consistency (areas of necrosis—hemorrhage—fibrosis—inflammation, the degree of vessels’ infiltration, the size of pancreatic and common bile duct and the distance from resection margins. Missed findings by imaging or pitfalls were recorded and we tried to explain all discrepancies between radiology evaluation and the histopathological findings. Radiologic-pathologic correlation is extremely important, adding crucial information on imaging limitations and enabling quality assessment of surgical specimens. The deep knowledge of different pancreatic tumors’ consistency and way of extension helps to improve radiologists’ diagnostic accuracy and minimize the radiological-surgical mismatching, preventing patients from unnecessary surgery.

  17. Evaluation of miniature tensile specimen fabrication techniques and performance

    Hamilton, M.L. (Pacific Northwest Lab., Richland, WA (United States)); Blotter, M.A.; Edwards, D.J. (Missouri Univ., Rolla, MO (United States))

    1992-01-01

    The confident application of miniature tensile specimens requires adequate control over their fabrication and is facilitated by automated test and analysis techniques. Three fabrication processes -- punching, chemical, milling, and electrical discharge machining (EDM) -- were recently evaluated, leading to the replacement of the previously used punching technique with a wire EDM technique. The automated data acquisition system was upgraded, and an interactive data analysis program was developed.

  18. Evaluation of miniature tensile specimen fabrication techniques and performance

    Hamilton, M.L.; Blotter, M.A.; Edwards, D.J.

    1992-01-01

    The confident application of miniature tensile specimens requires adequate control over their fabrication and is facilitated by automated test and analysis techniques. Three fabrication processes -- punching, chemical, milling, and electrical discharge machining (EDM) -- were recently evaluated, leading to the replacement of the previously used punching technique with a wire EDM technique. The automated data acquisition system was upgraded, and an interactive data analysis program was developed

  19. High Throughput Analysis of Breast Cancer Specimens on the Grid

    Yang, Lin; Chen, Wenjin; Meer, Peter; Salaru, Gratian; Feldman, Michael D.; Foran, David J.

    2007-01-01

    Breast cancer accounts for about 30% of all cancers and 15% of all cancer deaths in women in the United States. Advances in computer assisted diagnosis (CAD) holds promise for early detecting and staging disease progression. In this paper we introduce a Grid-enabled CAD to perform automatic analysis of imaged histopathology breast tissue specimens. More than 100,000 digitized samples (1200 × 1200 pixels) have already been processed on the Grid. We have analyzed results for 3744 breast tissue ...

  20. A mechanical microcompressor for high resolution imaging of motile specimens

    Zinskie, Jessica A.; Shribak, Michael; Bruist, Michael F.; Aufderheide, Karl J.; Janetopoulos, Chris

    2015-01-01

    In order to obtain fine details in 3 dimensions (3D) over time, it is critical for motile biological specimens to be appropriately immobilized. Of the many immobilization options available, the mechanical microcompressor offers many benefits. Our device, previously described, achieves gentle flattening of a cell, allowing us to image finely detailed structures of numerous organelles and physiological processes in living cells. We have imaged protozoa and other small metazoans using differenti...

  1. NEW TRIASSIC ASTEROIDEA (ECHINODERMATA SPECIMENS AND THEIR EVOLUTIONARY SIGNIFICANCE

    DANIEL B. BLAKE

    2017-04-01

    Full Text Available The Paleozoic-Mesozoic transition saw the disappearance of asteroid stem groups and the ascent of the crown group, but late Paleozoic and Triassic asteroids are rare and transition events are poorly documented. Three new Middle and Late Triassic specimens augment existing data; included are a specimen of Trichasteropsis weissmanni from Germany, a specimen of Trichasteropsis? sp. indet. from Italy, and a possible member of the extant Poraniidae from Slovenia. Presence of a small ossicle at the interbrachial midline and adjacent to the marginal series of the new T. weissmanni specimen is consistent with similar expressions not only of other trichasteropsids but also occurrence of two interbrachial ossicles in Paleozoic, stem-group asterozoans; presence is in turn consistent with a hypothesis of derivation of the axillary/odontophore coupling from two ossicles rather than direct derivation of the crown-group odontophore from a single stem-group axillary. Morphology of Trichasteropsis? sp. indet., including, for example, the evenly-tapering arms are reminiscent of those of diverse crown-group asteroids whereas the enlarged distal arms of T. weissmanni are unique, the morphology of T? sp. indet. thereby potentially indicative of a plesiomorphic, stemward positioning within the Trichasteropsiidae. The range of the Poraniidae is tentatively extended to the Carnian. Similarities shared by the Poraniidae and the Trichasteropsiidae suggest stemward positioning within crown-group diversification; however, known Triassic fossils do not appear closely related to extant taxa identified in recent molecular studies as basal within the crown-group. A temperate climate is suggested as preferred by the Triassic asteroids rather than a tropical, warmer one.

  2. A mechanical microcompressor for high resolution imaging of motile specimens.

    Zinskie, Jessica A; Shribak, Michael; Bruist, Michael F; Aufderheide, Karl J; Janetopoulos, Chris

    2015-10-01

    In order to obtain fine details in 3 dimensions (3D) over time, it is critical for motile biological specimens to be appropriately immobilized. Of the many immobilization options available, the mechanical microcompressor offers many benefits. Our device, previously described, achieves gentle flattening of a cell, allowing us to image finely detailed structures of numerous organelles and physiological processes in living cells. We have imaged protozoa and other small metazoans using differential interference contrast (DIC) microscopy, orientation-independent (OI) DIC, and real-time birefringence imaging using a video-enhanced polychromatic polscope. We also describe an enhancement of our previous design by engineering a new device where the coverslip mount is fashioned onto the top of the base; so the entire apparatus is accessible on top of the stage. The new location allows for easier manipulation of the mount when compressing or releasing a specimen on an inverted microscope. Using this improved design, we imaged immobilized bacteria, yeast, paramecia, and nematode worms and obtained an unprecedented view of cell and specimen details. A variety of microscopic techniques were used to obtain high resolution images of static and dynamic cellular and physiological events. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  4. National Aeronautics and Space Administration Biological Specimen Repository

    McMonigal, Kathleen A.; Pietrzyk, Robert a.; Johnson, Mary Anne

    2008-01-01

    The National Aeronautics and Space Administration Biological Specimen Repository (Repository) is a storage bank that is used to maintain biological specimens over extended periods of time and under well-controlled conditions. Samples from the International Space Station (ISS), including blood and urine, will be collected, processed and archived during the preflight, inflight and postflight phases of ISS missions. This investigation has been developed to archive biosamples for use as a resource for future space flight related research. The International Space Station (ISS) provides a platform to investigate the effects of microgravity on human physiology prior to lunar and exploration class missions. The storage of crewmember samples from many different ISS flights in a single repository will be a valuable resource with which researchers can study space flight related changes and investigate physiological markers. The development of the National Aeronautics and Space Administration Biological Specimen Repository will allow for the collection, processing, storage, maintenance, and ethical distribution of biosamples to meet goals of scientific and programmatic relevance to the space program. Archiving of the biosamples will provide future research opportunities including investigating patterns of physiological changes, analysis of components unknown at this time or analyses performed by new methodologies.

  5. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  6. Antarctic environmental specimen bank. A tool for chemical monitoring

    Soggia, F.; Dalla Riva, S.; Abelmoschi, M.L.; Frache, R. [Genoa Univ., Genoa (Italy). Dipt. di Chimica e Chimica Industriale

    2000-02-01

    The work illustrates the project on Antarctic Environmental Specimen Bank (BCAA), which is an integral part of the Italian project on the micropollutants chemistry (sector on chemical contamination of the Italian Antarctic Research program, PNRA), begun in 1994 when the BCAA was installed in the department of chemistry and industrial chemistry (Genoa University, Italy). Its objective underlines an emphasis on environmental chemistry and the establishment of baselines similar to the approaches followed by the other environmental specimen banks, begun at the end of Sixties with the aim of long-term storage of representative environmental specimens in order to study the presence and the evolution of dangerous substances, but focus on the chemical characterization of samples. [Italian] Il lavoro illustra le finalita' del Progetto su una Banca Campioni Ambientali Antartici (BCAA), che e' parte integrante del progetto Chmica dei microinquinannti del Settore Contaminazione chimica del Programma Nazionale di ricerche in Antartide (ONRA), nata nel 1994 presso il dipartimento di chimicia e chimica industriale dell'universita' di Genova. A differenza di altri progetti internazionali che enfatizzano gli aspetti biologici, ecologici e medici, il progetto BCAA enfatizza la chimica ambientale.

  7. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-01-01

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  8. Improved specimen reconstruction by Hilbert phase contrast tomography.

    Barton, Bastian; Joos, Friederike; Schröder, Rasmus R

    2008-11-01

    The low signal-to-noise ratio (SNR) in images of unstained specimens recorded with conventional defocus phase contrast makes it difficult to interpret 3D volumes obtained by electron tomography (ET). The high defocus applied for conventional tilt series generates some phase contrast but leads to an incomplete transfer of object information. For tomography of biological weak-phase objects, optimal image contrast and subsequently an optimized SNR are essential for the reconstruction of details such as macromolecular assemblies at molecular resolution. The problem of low contrast can be partially solved by applying a Hilbert phase plate positioned in the back focal plane (BFP) of the objective lens while recording images in Gaussian focus. Images recorded with the Hilbert phase plate provide optimized positive phase contrast at low spatial frequencies, and the contrast transfer in principle extends to the information limit of the microscope. The antisymmetric Hilbert phase contrast (HPC) can be numerically converted into isotropic contrast, which is equivalent to the contrast obtained by a Zernike phase plate. Thus, in-focus HPC provides optimal structure factor information without limiting effects of the transfer function. In this article, we present the first electron tomograms of biological specimens reconstructed from Hilbert phase plate image series. We outline the technical implementation of the phase plate and demonstrate that the technique is routinely applicable for tomography. A comparison between conventional defocus tomograms and in-focus HPC volumes shows an enhanced SNR and an improved specimen visibility for in-focus Hilbert tomography.

  9. Preparation of TEM specimen by cross-section technique

    Hamada, Shozo

    1986-01-01

    Transmission electron microscopy (TEM) is applied to the direct observation of the depth dependent damage structure in ion-irradiated stainless steel by using the cross-section technique; obtaining the TEM specimen from a slice of the irradiated stainless steel with thick Ni plating. Here has been developed the specimen preparation method of cross-section technique without heat treatment, which was necessary in the conventional method to strengthen the bonding between Ni and stainless steel. Nickel plating with good bonding to stainless steel is enabled by the following manner. First, the irradiated stainless steel is immersed in the Wood's nickel solution at room temperature for 60s to activate the surface, followed by the stricking for 300s at a current density of 300 A/m 2 in the solution to make fine and homogeneous nucleation of Ni on the stainless steel. Then, the sample is plated with Ni in the Watt's nickel plating solution at 333 K with current density of 900 ∼ 1,000 A/m 2 . The TEM disc is obtained by mechanical slicing from the specimen with Ni plating of more than 3 mm thickness. Electropolishing is accomplished by using both Ballmann method and jet electropolishing to perforate the disc accurately at the aimed point for the observation of the damage structure. (author)

  10. Electronprobe X-ray microanalysis of biological specimens improvement of a number of quantification procedures

    Boekestein, A.

    1984-01-01

    In this thesis an investigation is described to establish which quantification procedures can be used in the X-ray microanalysis of biological specimens. Two classes of specimens have been distinguished from each other, i.e. thick specimens (opaque to the beam electrons) and thin specimens (transparent to the beam electrons). (Auth.)

  11. Influence of impacts on static and low-cycle fatigue characteristics of composite specimens (Draft)

    Walters, C.L.

    2012-01-01

    This paper describes the effect of impacts on the possible reduction of the structural characteristics and damage growth of graphite-epoxy specimens. The considered specimens are undamaged specimens and specimens impacted with two different energy levels. In particular, barely visible impact damage

  12. The Venice specimen of Ouranosaurus nigeriensis (Dinosauria, Ornithopoda

    Filippo Bertozzo

    2017-06-01

    Full Text Available Ouranosaurus nigeriensis is an iconic African dinosaur taxon that has been described on the basis of two nearly complete skeletons from the Lower Cretaceous Gadoufaoua locality of the Ténéré desert in Niger. The entire holotype and a few bones attributed to the paratype formed the basis of the original description by Taquet (1976. A mounted skeleton that appears to correspond to O. nigeriensis has been on public display since 1975, exhibited at the Natural History Museum of Venice. It was never explicitly reported whether the Venice specimen represents a paratype and therefore, the second nearly complete skeleton reported in literature or a third unreported skeleton. The purpose of this paper is to disentangle the complex history of the various skeletal remains that have been attributed to Ouranosaurus nigeriensis (aided by an unpublished field map of the paratype and to describe in detail the osteology of the Venice skeleton. The latter includes the paratype material (found in 1970 and collected in 1972, with the exception of the left femur, the right coracoid and one manus ungual phalanx I, which were replaced with plaster copies, and (possibly other manus phalanges. Some other elements (e.g., the first two chevrons, the right femur, the right tibia, two dorsal vertebrae and some pelvic bones were likely added from other individual/s. The vertebral column of the paratype was articulated and provides a better reference for the vertebral count of this taxon than the holotype. Several anatomical differences are observed between the holotype and the Venice specimen. Most of them can be ascribed to intraspecific variability (individual or ontogenetic, but some are probably caused by mistakes in the preparation or assemblage of the skeletal elements in both specimens. The body length of the Venice skeleton is about 90% the linear size of the holotype. Osteohistological analysis (the first for this taxon of some long bones, a rib and a dorsal

  13. The Venice specimen of Ouranosaurus nigeriensis (Dinosauria, Ornithopoda).

    Bertozzo, Filippo; Dalla Vecchia, Fabio Marco; Fabbri, Matteo

    2017-01-01

    Ouranosaurus nigeriensis is an iconic African dinosaur taxon that has been described on the basis of two nearly complete skeletons from the Lower Cretaceous Gadoufaoua locality of the Ténéré desert in Niger. The entire holotype and a few bones attributed to the paratype formed the basis of the original description by Taquet (1976). A mounted skeleton that appears to correspond to O. nigeriensis has been on public display since 1975, exhibited at the Natural History Museum of Venice. It was never explicitly reported whether the Venice specimen represents a paratype and therefore, the second nearly complete skeleton reported in literature or a third unreported skeleton. The purpose of this paper is to disentangle the complex history of the various skeletal remains that have been attributed to Ouranosaurus nigeriensis (aided by an unpublished field map of the paratype) and to describe in detail the osteology of the Venice skeleton. The latter includes the paratype material (found in 1970 and collected in 1972), with the exception of the left femur, the right coracoid and one manus ungual phalanx I, which were replaced with plaster copies, and (possibly) other manus phalanges. Some other elements (e.g., the first two chevrons, the right femur, the right tibia, two dorsal vertebrae and some pelvic bones) were likely added from other individual/s. The vertebral column of the paratype was articulated and provides a better reference for the vertebral count of this taxon than the holotype. Several anatomical differences are observed between the holotype and the Venice specimen. Most of them can be ascribed to intraspecific variability (individual or ontogenetic), but some are probably caused by mistakes in the preparation or assemblage of the skeletal elements in both specimens. The body length of the Venice skeleton is about 90% the linear size of the holotype. Osteohistological analysis (the first for this taxon) of some long bones, a rib and a dorsal neural spine

  14. Evaluation of the Behavior of Technova Corporation Rod-Stiffened Stitched Compression Specimens

    Jegley, Dawn C.

    2013-01-01

    Under Space Act Agreement 1347 between NASA and Technova Corporation, Technova designed and fabricated two carbon-epoxy crippling specimens and NASA loaded them to failure in axial compression. Each specimen contained a pultruded rod stiffener which was held to the specimen skin with through-the-thickness stitches. One of these specimens was designed to be nominally the same as pultruded rod stitched specimens fabricated by Boeing under previous programs. In the other specimen, the rod was prestressed in a Technova manufacturing process to increase its ability to carrying compressive loading. Experimental results demonstrated that the specimen without prestressing carried approximately the same load as the similar Boeing specimens and that the specimen with prestressing carried significantly more load than the specimen without prestressing.

  15. Process-response coastal-recession model and its application to the Holderness coast (UK); Modelo proceso-respuesta de recesion de acantilados por variacion del nivel del mar. Aplicacion en la Costa de Holderness (Reino Unido)

    Castedo, R.; Paredes, C.; Fernandez, M.; Vega, R. de la

    2012-11-01

    At the moment the development of predictive cliff-erosion models is limited from a geomorphologic perspective due to the complex interactions existing between coupled processes acting over wide scales of time and space. Current models incorporate a probabilistic framework in order to simulate coastal recession events or cliff failure and tend to assess the effects of climate change through changes in the mean sea lea level. According to this procedure, the resulting simulations of cliffs with different behaviours might produce identical annual retreat characteristics even if their potential response to changing environments may not be the same. Thus, a new process-response model is developed to incorporate the behavioural characteristics of cohesive clay coasts with a protective talus wedge under erosive processes. To this end, the model incorporates dynamic marine processes such as variations in mean sea level, tides and waves together with cliff evolution in the shape of erosion, cliff failure and the formation of foot talus deposits. Cliff erosion is calculated on the basis of sea-level changes, wave incidence, shore platform slope and the uniaxial compressive strength of the rock over each tidal cycle. After each cycle the geomechanical stability against topple movement of the cliff face is evaluated and in the event of failure, a talus wedge is formed. The model has been corroborated by an assessment of profile evolution at various locations along a rapidly retreating area on the coast of Holderness in the UK. The results represent an important step-forward in linking material properties to cliff recession processes and the subsequent long-term coastal response in the face of changing sea-level conditions. (Author) 72 refs.

  16. Assessment of plastic flow and fracture properties with small specimens test techniques for IFMIF-designed specimens

    Spaetig, P.; Campitelli, E.N.; Bonade, R.; Baluc, N.

    2005-01-01

    The primary mission of the International Fusion Material Irradiation Facility (IFMIF) is to generate a material database to be used for the design of various components, for the licensing and for the assessment of the safe operation of a demonstration fusion reactor. IFMIF is an accelerator-based high-energy neutron source whose irradiation volume is quite limited (0.5 l for the high fluence volume). This requires the use of small specimens to measure the irradiation-induced changes on the physical and mechanical properties of materials. In this paper, we developed finite element models to better analyze the results obtained with two different small specimen test techniques applied to the tempered martensitic steel F82H-mod. First, one model was used to reconstruct the load-deflection curves of small ball punch tests, which are usually used to extract standard tensile parameters. It was shown that a reasonable assessment of the overall plastic flow can be done with small ball punch tests. Second, we investigated the stress field sensitivity at a crack tip to the constitutive behavior, for a crack modeled in plane strain, small-scale yielding and fracture mode I conditions. Based upon a local criterion for cleavage, that appears to be the basis to account for the size and geometry effects on fracture toughness, we showed that the details of the constitutive properties play a key role in modeling the irradiation-induced fracture toughness changes. Consequently, we suggest that much more attention and efforts have to be paid in investigating the post-yield behavior of the irradiated specimens and, in order to reach this goal, we recommend the use of not only tensile specimens but also that of compression ones in the IFMIF irradiation matrices. (author)

  17. Preparation and Loading Process of Single Crystalline Samples into a Gas Environmental Cell Holder for In Situ Atomic Resolution Scanning Transmission Electron Microscopic Observation.

    Straubinger, Rainer; Beyer, Andreas; Volz, Kerstin

    2016-06-01

    A reproducible way to transfer a single crystalline sample into a gas environmental cell holder for in situ transmission electron microscopic (TEM) analysis is shown in this study. As in situ holders have only single-tilt capability, it is necessary to prepare the sample precisely along a specific zone axis. This can be achieved by a very accurate focused ion beam lift-out preparation. We show a step-by-step procedure to prepare the sample and transfer it into the gas environmental cell. The sample material is a GaP/Ga(NAsP)/GaP multi-quantum well structure on Si. Scanning TEM observations prove that it is possible to achieve atomic resolution at very high temperatures in a nitrogen environment of 100,000 Pa.

  18. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    Islam, N; Xiong, Z; Vijayan, S; Rudin, S; Bednarek, D

    2015-01-01

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant

  19. Heat Transfer Analysis of an Optimized, Flexible Holder System for Freeze-Drying in Dual Chamber Cartridges Using Different State-of-the-Art PAT Tools.

    Korpus, Christoph; Pikal, Michael; Friess, Wolfgang

    2016-11-01

    The aim of this study was to determine the heat transfer characteristics of an optimized flexible holder device, using Tunable Diode Laser Absorption Spectroscopy, the Pressure Rise Test, and the gravimetric procedure. Two different controlled nucleation methods were tested, and an improved sublimation process, "preheated plate," was developed. Tunable Diode Laser Absorption Spectroscopy identified an initial sublimation burst phase. Accordingly, steady-state equations were adapted for the gravimetric procedure, to account for this initial non-steady-state period. The heat transfer coefficient, K DCC , describing the transfer from the holder to the DCC, was the only heat transfer coefficient showing a clear pressure dependence with values ranging from 3.81E-04 cal/(g·cm 2 ·K) at 40 mTorr to 7.38E-04 cal/(g·cm 2 ·K) at 200 mTorr. The heat transfer coefficient, K tot , reflecting the overall energy transfer via the holder, increased by around 24% from 40 to 200 mTorr. This resulted in a pressure-independent sublimation rate of around 42 ± 1.06 mg/h over the whole pressure range. Hence, this pressure-dependent increase in energy transfer completely compensated the decrease in driving force of sublimation. The "flexible holder" shows a substantially reduced impact of atypical radiation, improved drying homogeneity, and ultimately a better transferability of the freeze-drying cycle for process optimization. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  20. SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

    Islam, N; Xiong, Z; Vijayan, S; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2015-06-15

    Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant.

  1. [The randomized controlled trial of the treatment for clavicular fracture by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation].

    Bi, Hong-zheng; Yang, Mao-qing; Tan, Yuan-chao; Fu, Song

    2008-07-01

    To study the curative effect and safety of rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation in treating clavicular fracture. All 201 cases of clavicular fractures were randomly divided into treatment group (101 cases) and control group (100 cases). The treatment group was treated by rotatory manual reduction with forceps holder and retrograde percutaneous pinning transfixation. The control group was treated by open reduction and internal fixation with Kirschner pin. All cases were followed up for 4 to 21 months (mean 10.6 months). SPSS was used to analyze clinic healing time of fracture and shoulder-joint function in both two groups. After operation, 101 cases of treatment group achieved union of fracture and the clinical healing time was 28 to 49 days (mean 34.5+/-2.7 days). In control group,there were 4 cases with nonunion of fracture,the other 96 cases were union,the clinical healing time was 36 to 92 days (mean 55.3+/-4.8 days). The excellent and good rate of shoulder-joint function was 100% in treatment group and 83% in control group. By t-test and chi2-test, there was significant difference between the two groups in curative effect (Pmanual reduction with forceps holder and retrograde pinning transfixation can be used in various kinds of clavicular shaft fracture, with many virtues such as easy operation, reliable fixation, short union time of fracture, good functional recovery of shoulder-joint and no incision scar affecting appearance.

  2. The preventive Control of White Root Rot Disease in Small Holder Rubber Plantation Using Botanical, Biological and Chemical Agents

    Joko Prasetyo

    2014-03-01

    Full Text Available The preventive control of white root rot disease in small holder plantation using botanical, biological, and chemical agents. A field and laboratory experiment were conducted from June 2008 to December 2009 in Panumangan, Tulang Bawang - Lampung. The  field experiment was intended to evaluate the effect of  botanical plants (Alpinia galanga, Sansiviera auranthii, and Marantha arundinacea, biological agents (organic matter and Trichoderma spp., and chemical agents (lime and natural sulphur on the incidence of white root rot disease and population of some soil microbes. The laboratory experiment was conducted  to observe the mechanism of botanical agents  in controlling white root rot disease. In the field experiment, the treatments were applied  in the experimental plot with cassava plant infection as the indicator. The variables  examined were the incidence of  white root rot and population of soil microbes. In the laboratory experiment, culture of R. microporus was grown in PDA containing root exudate of the antagonistic plant (botanical agent. The variable examined was colony diameter of R. microporus growing in the PDA plates. The results of the  field experiment  showed that planting of the botanical agents, and application of Trichoderma spp., as well as natural sulphur, decreased the incidence of white root rot disease. The effectiveness of M. arundinacea and Trichoderma spp. was comparable to natural  sulphur. The laboratory experiment showed only root exudate of  A. galanga and  S. auranthii that were significantly inhibit the growth of R. microporus.

  3. Dishevelled binds the Discs large 'Hook' domain to activate GukHolder-dependent spindle positioning in Drosophila.

    Joshua D Garcia

    Full Text Available Communication between cortical cell polarity cues and the mitotic spindle ensures proper orientation of cell divisions within complex tissues. Defects in mitotic spindle positioning have been linked to various developmental disorders and have recently emerged as a potential contributor to tumorigenesis. Despite the importance of this process to human health, the molecular mechanisms that regulate spindle orientation are not fully understood. Moreover, it remains unclear how diverse cortical polarity complexes might cooperate to influence spindle positioning. We and others have demonstrated spindle orientation roles for Dishevelled (Dsh, a key regulator of planar cell polarity, and Discs large (Dlg, a conserved apico-basal cell polarity regulator, effects which were previously thought to operate within distinct molecular pathways. Here we identify a novel direct interaction between the Dsh-PDZ domain and the alternatively spliced "I3-insert" of the Dlg-Hook domain, thus establishing a potential convergent Dsh/Dlg pathway. Furthermore, we identify a Dlg sequence motif necessary for the Dsh interaction that shares homology to the site of Dsh binding in the Frizzled receptor. Expression of Dsh enhanced Dlg-mediated spindle positioning similar to deletion of the Hook domain. This Dsh-mediated activation was dependent on the Dlg-binding partner, GukHolder (GukH. These results suggest that Dsh binding may regulate core interdomain conformational dynamics previously described for Dlg. Together, our results identify Dlg as an effector of Dsh signaling and demonstrate a Dsh-mediated mechanism for the activation of Dlg/GukH-dependent spindle positioning. Cooperation between these two evolutionarily-conserved cell polarity pathways could have important implications to both the development and maintenance of tissue homeostasis in animals.

  4. A Tale of Two Majors: Explaining the Gender Gap in STEM Employment among Computer Science and Engineering Degree Holders

    Sharon Sassler

    2017-07-01

    Full Text Available We examine factors contributing to the gender gap in employment in science, technology, engineering, and math (STEM among men and women with bachelor’s degrees in computer science and engineering, the two largest and most male-dominated STEM fields. Data come from the National Science Foundation’s (NSF Scientists and Engineers Statistical Data System (SESTAT from 1995 to 2008. Different factors are associated with persistence in STEM jobs among computer science and engineering degree holders. Conditional on receiving a degree in computer science, women are 14 percentage points less likely to work in STEM than their male counterparts. Controlling for demographic and family characteristics did little to change this gender gap. Women with degrees in engineering are approximately 8 percentage points less likely to work in STEM than men, although about half of this gap is explained by observed differences between men and women. We document a widening gender gap in STEM employment in computer science, but this gender gap narrows across college cohorts among those with degrees in engineering. Among recent computer science graduates, the gender gap in STEM employment for white, Hispanic, and black women relative to white men is even larger than for older graduates. Gender and race gaps in STEM employment for recent cohorts of engineering graduates are generally small, though younger Asian women and men no longer have an employment advantage relative to white men. Our results suggest that a one-size-fits-all approach to increasing women’s representation in the most male-dominated STEM fields may not work.

  5. Specimen-specific modeling of hip fracture pattern and repair.

    Ali, Azhar A; Cristofolini, Luca; Schileo, Enrico; Hu, Haixiang; Taddei, Fulvia; Kim, Raymond H; Rullkoetter, Paul J; Laz, Peter J

    2014-01-22

    Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50% due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59%:41% to 89%:11%, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants. © 2013 Published by Elsevier Ltd.

  6. Effect of ultraviolet light on creatinine measurement in jaundiced specimens

    Nisbet, J.A.; D'Souza, R.

    1986-01-01

    During initial evaluation of a creatinine method using the RA-1000 analyser, experiments with addition of bilirubin indicated negligible interference. However the finding of a 'zero' creatinine value in an extremely jaundiced specimen prompted to re-examine the method. In contrast to earlier findings with normal plasma containing added bilirubin, the authors found that plasma from moderately or severely jaundiced patients gave creatinine values lower than those obtained with a reference method. Since bilirubin has been implicated in the interference, the authors studied the effect of destroying bilirubin with ultraviolet light to see if this provided a practical solution to the problem. (Auth.)

  7. Condition For Strain-Hardening In Ecc Uniaxial Test Specimen

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    and infinite sheets under uniaxial tension. The crack is assumed to be cohesive and the cohesive law applied takes into account fiber as well as mortar properties. It is shown that the maximum crack opening observed during crack propagation in various test specimen geometries is small, 20 m and also small......This paper discusses the adequateness of the steady state flat crack criterion for crack propagation in Engineered Cementitious Composites. The investigation is performed by use of a semi-analytical model as well as a Finite Element Model. The simulations are for one crack propagating in finite...

  8. Miniaturized fatigue crack growth specimen technology and results

    Puigh, R.J.; Bauer, R.E.; Ermi, A.M.; Chin, B.A.

    1981-01-01

    The miniature fatigue crack propagation technology has been extended to in-cell fabrication of irradiated specimens. Baseline testing of selected titanium alloys has been performed at 25 0 C in air. At relatively small values for the stress intensity factor, ΔK, the crack growth rates for all titanium alloys investigated are within a factor of three. The crack growth rates for these titanium alloys are a factor of three greater than the crack growth rates of either 316SS (20% CW) or HT-9. Each of the titanium alloys has observable crack propagation for stress intensity factors as small as 4.2 MPa√m

  9. A new procedure for making TEM specimens of superconductor devices

    Huang, Y.; Merkle, K.L.

    1997-04-01

    A new procedure is developed for making TEM specimens of thin film devices. In this procedure the sample is flatly polished to an overall ion-mill-ready thickness so that any point in the 2-D sample pane can be thinned to an electron-transparent thickness by subsequent ion-milling. Using this procedure, small regions of interest can be easily reached in both cross-section and plan-view samples. This is especially useful in device studies. Applications of this procedure to the study of superconductor devices yield good results. This procedure, using commercially available equipment and relatively cheap materials, is simple and easy to realize

  10. Development of electric discharge equipment for small specimen sampling

    Okamoto, Koji; Kitagawa, Hideaki; Kusumoto, Junichi; Kanaya, Akihiro; Kobayashi, Toshimi

    2009-01-01

    We have developed the on-site electric discharge sampling equipment that can effectively take samples such as small specimens from the surface portion of the plant components. Compared with the conventional sampling equipment, our sampling equipment can take samples that are thinner in depth and larger in area. In addition, the affection to the equipment can be held down to the minimum, and the thermally-affected zone of the material due to electric discharge is small, which is to be ignored. Therefore, our equipment is excellent in taking samples for various tests such as residual life evaluation.

  11. Innovations in macroscopic evaluation of pancreatic specimens and radiologic correlation

    Triantopoulou, Charikleia; Papaparaskeva, Kleo; Agalianos, Christos; Dervenis, Christos

    2016-01-01

    •The axial slicing technique offers many advantages in accurate estimation of tumors extend and staging.•Cross-sectional axial imaging is the best technique for accurate radiologic-pathologic correlation.•Correlation may explain any discrepancies between radiological and histopathological findings.•Pathology correlation may offer a better understanding of the missed findings by imaging or pitfalls The axial slicing technique offers many advantages in accurate estimation of tumors extend and staging. Cross-sectional axial imaging is the best technique for accurate radiologic-pathologic correlation. Correlation may explain any discrepancies between radiological and histopathological findings. Pathology correlation may offer a better understanding of the missed findings by imaging or pitfalls The purpose of this study was to evaluate the feasibility of a novel dissection technique of surgical specimens in different cases of pancreatic tumors and provide a radiologic pathologic correlation. In our hospital, that is a referral center for pancreatic diseases, the macroscopic evaluation of the pancreatectomy specimens is performed by the pathologists using the axial slicing technique (instead of the traditional procedure with longitudinal opening of the main pancreatic and/or common bile duct and slicing along the plane defined by both ducts). The specimen is sliced in an axial plane that is perpendicular to the longitudinal axis of the descending duodenum. The procedure results in a large number of thin slices (3–4 mm). This plane is identical to that of CT or MRI and correlation between pathology and imaging is straightforward. We studied 70 cases of suspected different solid and cystic pancreatic tumors and we correlated the tumor size and location, the structure—consistency (areas of necrosis—hemorrhage—fibrosis—inflammation), the degree of vessels’ infiltration, the size of pancreatic and common bile duct and the distance from resection margins

  12. Dose determination of 600 MeV proton irradiated specimens

    Gavillet, D.

    1991-01-01

    The calculation method for the experimental determination of the atomic production cross section from the γ activity measurements are presented. This method is used for the determination of some isotope production cross sections for 600 MeV proton irradition in MANET steel, copper, tungsten, gold and titanium. The results are compared with some calculation. These values are used to determine the dose of specimens irradiated in the PIREX II facility. The results are discussed in terms of the irradiation parameters. A guide for the use of the production cross section determined in the dosimetry experiment are given. (author) tabs., refs

  13. Improved support films for electron microscopy of beam sensitive specimens

    Taylor, J.R.; Glaeser, R.M.

    1987-01-01

    Preliminary results indicate that technical innovations can address the problem of beam-induced movement and provide improved prospects for high resolution imaging of beam-sensitive specimens. Second-generation experiments with microgrid supports are in progress with efforts focusing on the objectives of maximizing the contact between the carbon film and its microgrid support and on improving the flatness of microgrids. When more robust support films are available they will be used in conjunction with small spot illumination. 4 refs., 2 figs

  14. Fecal specimens preparation methods for PCR diagnosis of human taeniosis

    Nunes Cáris Maroni

    2006-01-01

    Full Text Available Sample preparation and DNA extraction protocols for DNA amplification by PCR, which can be applied in human fecal samples for taeniasis diagnosis, are described. DNA extracted from fecal specimens with phenol/chloroform/isoamilic alcohol and DNAzol® reagent had to be first purified to generate fragments of 170 pb and 600 pb by HDP2-PCR. This purification step was not necessary with the use of QIAmp DNA stool mini kit®. Best DNA extraction results were achieved after eggs disruption with glass beads, either with phenol/chloroform/isoamilic alcohol, DNAzol® reagent or QIAmp DNA stool mini kit®.

  15. Derfor holder stamceller sammen

    Keiding, Johanne

    2013-01-01

    Professor Joshua Brickman fra DanStem har i samarbejde med forskere fra The MRC Centre for Regenerative Medicine (CRM) ved University of Edinburgh identificeret en række faktorer, som regulerer embryonale stamcellers evne til at forny sig selv. Et af de centrale elementer er proteinet Oct4, og...

  16. Patients as Rights Holders.

    Brännmark, Johan

    2017-07-01

    Autonomy and consent have been central values in Western moral and political thought for centuries. One way of understanding the bioethical models that started to develop, especially in the 1970s, is that they were about the fusion of a long-standing professional ethics with the core values underpinning modern political institutions. That there was a need for this kind of fusion is difficult to dispute, especially since the provision of health care has in most developed countries become an ever more important concern of our political institutions, with governments playing a significant role in regulating and facilitating the provision of health care and in many countries even largely organizing it. There is, nevertheless, still room for dispute about how best to achieve this fusion and how to best think about autonomy and consent in a biomedical context. The simplest model we can have is probably about how being a person is largely about having the capacity of autonomous choice and that the main mode through which we exercise autonomy is by providing informed consent. Yet, liberal democracy's core idea that human beings have a high and equal value is also found in other accounts of the person. The human-rights framework provides an alternative model for thinking about personhood and about patient care. The human-rights approach is grounded, not in an account of autonomy (although it has something to say about autonomy), but in an account of the moral and political personhood that people possess merely by being human beings. In this approach, values like dignity and integrity, both highly relevant in a bioethical context, are identified as distinct values rather than being derived from and therefore reduced to respect for autonomous choice. The human-rights approach can supplement the problematic notion of autonomy that has been central to bioethics by placing this notion in a broader, strongly pluralistic framework. © 2017 The Hastings Center.

  17. Review of forensically important entomological specimens collected from human cadavers in Malaysia (2005-2010).

    Kavitha, Rajagopal; Nazni, Wasi Ahmad; Tan, Tian Chye; Lee, Han Lim; Azirun, Mohd Sofian

    2013-07-01

    Forensic entomological specimens collected from human decedents during crime scene investigations in Malaysia in the past 6 years (2005-2010) are reviewed. A total of 80 cases were recorded and 93 specimens were collected. From these specimens, 10 species of cyclorrphagic flies were identified, consisting of Chrysomya rufifacies (Macquart) -38 specimens (40.86%), Chrysomya megacephala (Fabricius) -36 specimens (38.70%), Chrysomya villeneuvi (Patton) -2 specimens (2.15%), Chrysomya nigripes (Aubertin) -2 specimens (2.15%), Chrysomya pinguis (Walker) -1 specimen (1.08%), Hermetia illucens (Linnaeus) -1 specimen (1.08%), Hemipyrellia liguriens (Wiedemann) -5 specimens (5.37%), Synthesiomyia nudiseta (Wulp) -1 specimen (1.08%), Megaselia scalaris (Loew)-1 specimen (1.08%) and Sarcophaga ruficornis (Fabricius) -4 specimens (4.30%). In two specimens (2.15%), the maggots were not identifiable. Ch. megacephala and Ch. rufifacies were the commonest species found in human decedents from three different ecological habitats. S. nudiseta is an uncommon species found only on human cadavers from indoors. A total of 75 cases (93.75%) had a single fly infestation and 5 cases (6.25%) had double fly infestation. In conclusion, although large numbers of fly species were found on human decedents, the predominant species are still those of Chrysomya. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  18. Characterization of Two Historic Smallpox Specimens from a Czech Museum.

    Pajer, Petr; Dresler, Jiri; Kabíckova, Hana; Písa, Libor; Aganov, Pavel; Fucik, Karel; Elleder, Daniel; Hron, Tomas; Kuzelka, Vitezslav; Velemínsky, Petr; Klimentova, Jana; Fucikova, Alena; Pejchal, Jaroslav; Hrabakova, Rita; Benes, Vladimir; Rausch, Tobias; Dundr, Pavel; Pilin, Alexander; Cabala, Radomir; Hubalek, Martin; Stríbrny, Jan; Antwerpen, Markus H; Meyer, Hermann

    2017-07-27

    Although smallpox has been known for centuries, the oldest available variola virus strains were isolated in the early 1940s. At that time, large regions of the world were already smallpox-free. Therefore, genetic information of these strains can represent only the very last fraction of a long evolutionary process. Based on the genomes of 48 strains, two clades are differentiated: Clade 1 includes variants of variola major, and clade 2 includes West African and variola minor (Alastrim) strains. Recently, the genome of an almost 400-year-old Lithuanian mummy was determined, which fell basal to all currently sequenced strains of variola virus on phylogenetic trees. Here, we determined two complete variola virus genomes from human tissues kept in a museum in Prague dating back 60 and 160 years, respectively. Moreover, mass spectrometry-based proteomic, chemical, and microscopic examinations were performed. The 60-year-old specimen was most likely an importation from India, a country with endemic smallpox at that time. The genome of the 160-year-old specimen is related to clade 2 West African and variola minor strains. This sequence likely represents a new endemic European variant of variola virus circulating in the midst of the 19th century in Europe.

  19. Clinicopathologic features of incidental prostatic adenocarcinoma in radical cystoprostatectomy specimens

    Vuruskan Hakan

    2011-07-01

    Full Text Available Abstract Background The aim of this study is to review all features of incidentally discovered prostate adenocarcinoma in patients undergoing radical cystoprostatectomy for bladder cancer. Methods The medical charts of 300 male patients who underwent radical cystoprostatectomy for bladder cancer between 1997 and 2005 were retrospectively reviewed. The mean age of the patients was 62 (range 51-75 years. Results Prostate adenocarcinoma was present in 60 (20% of 300 specimens. All were acinar adenocarcinoma. Of these, 40 (66.7% were located in peripheral zone, 20 (33.3% had pT2a tumor, 12 (20% had pT2b tumor, 22(36.7% had pT2c and, 6 (10% had pT3a tumor. Gleason score was 6 or less in 48 (80% patients. Surgical margins were negative in 54 (90% patients, and tumor volume was less than 0.5 cc in 23 (38.3% patients. Of the 60 incidentally detected cases of prostate adenocarcinoma 40 (66.7% were considered clinically significant. Conclusion Incidentally detected prostate adenocarcinoma is frequently observed in radical cystoprostatectomy specimens. The majority are clinically significant.

  20. Monokinetic electron backsttering from amorphous or polycrystalline specimens

    Ahmed, H.E.D.H.

    1983-06-01

    We have considered the interaction of electrons with thin amorphous specimens: one part of these electrons is transmitted through the substance, the other being backscattered. This last phenomena, which is not perfectly understood, has been studied in the energy range from 0.3 to 3 MeV. First this work deals with the realization of a fully automatic apparatus which has been adapted to the column of the 3 MeV electron microscope of the HVFM laboratory in Toulouse. The variation of the transmission and backscattering coefficients, for amorphous and polycrystalline specimens, is determined. From this coefficient the electron range in this substance can be deduced. In addition the experimental results can be used to understand the image contrast in scanning electron microscopy. A short presentation of the cross-section, introduces the theoretical study of Monte-Carlo calculation. The Monte-Carlo calculation is used to take into account all elementary processus, which take place during electron scattering [fr

  1. Characterization of some biological specimens using TEM and SEM

    Ghosh, Nabarun; Smith, Don W.

    2009-05-01

    The advent of novel techniques using the Transmission and Scanning Electron Microscopes improved observation on various biological specimens to characterize them. We studied some biological specimens using Transmission and Scanning Electron Microscopes. We followed negative staining technique with Phosphotungstic acid using bacterial culture of Bacillus subtilis. Negative staining is very convenient technique to view the structural morphology of different samples including bacteria, phage viruses and filaments in a cell. We could observe the bacterial cell wall and flagellum very well when trapped the negative stained biofilm from bacterial culture on a TEM grid. We cut ultra thin sections from the fixed root tips of Pisum sativum (Garden pea). Root tips were pre fixed with osmium tetroxide and post fixed with uranium acetate and placed in the BEEM capsule for block making. The ultrathin sections on the grid under TEM showed the granular chromatin in the nucleus. The protein bodies and large vacuoles with the storage materials were conspicuous. We followed fixation, critical point drying and sputter coating with gold to view the tissues with SEM after placing on stubs. SEM view of the leaf surface of a dangerous weed Tragia hispida showed the surface trichomes. These trichomes when break on touching releases poisonous content causing skin irritation. The cultured tissue from in vitro culture of Albizia lebbeck, a tree revealed the regenerative structures including leaf buds and stomata on the tissue surface. SEM and TEM allow investigating the minute details characteristic morphological features that can be used for classroom teaching.

  2. Anticorrosion ion implantation of fragments of zirconium fuel can specimens

    Kalin, B.A.; Osipov, V.V.; Volkov, N.V.; Khernov, V.Yu.

    2001-01-01

    Aimed at the study of specific features of oxide film formation in the initial stage of Eh110 and Eh635 alloy fuel can oxidation the modification of tubular specimen surfaces is performed using an ion mixing technique, and the structure of oxide films produced in a steam-water environment is investigated. Using the method of vacuum vapor deposition the outer surface of specimens is coated with alloying element films irradiated by a polyenergetic Ar + ion beam with a 10 keV mean energy up to radiation doses of (7-10) x 10 17 ion/cm 2 . Monatomic (Al, Fe, Cu, Cr, Mo, Sn) or diatomic (Al-Fe, Al-Mo, Al-Sn, Fe-Cu, Fe-Mo, Fe-Sn, Cr-Mo, Cr-Sn) implantation into a zirconium cladding occurs under irradiation effect. The positive influence of combined intrusion of Al and other elements is revealed. The presence of Al atoms enhances the oxide film structure. The least ZeO 2 film thickness is observed when alloying with molybdenum, Al-Fe, Al-Mo and Al-Sn [ru

  3. Photogrammetric analysis of concrete specimens and structures for condition assessment

    D'Amico, Nicolas; Yu, Tzuyang

    2016-04-01

    Deterioration of civil infrastructure in America demands routine inspection and maintenance to avoid catastrophic failures from occurring. Among many other non-destructive evaluations (NDE), photogrammetry is an accessible and realistic approach used for non-destructive evaluation (NDE) of a civil infrastructure systems. The objective of this paper is to explore the capabilities of photogrammetry for locating, sizing, and analyzing the remaining capacity of a specimen or system using point cloud data. Geometric interpretations, composed from up to 70 photographs are analyzed as a mesh or point cloud models. In this case study, concrete, which exhibits a large amount of surface texture features, was thoroughly examined. These evaluative techniques discussed were applied to concrete cylinder models as well as portions of civil infrastructure including buildings, retaining walls, and bridge abutments. In this paper, the aim is to demonstrate the basic analytical functionality of photogrammetry, as well as its applicability to in-situ civil infrastructure systems. In concrete specimens defect length and location can be evaluated in a fully defined model (one with the maximum amount of correctly acquired photographs) with less than 2% error. Error was found to be inversely proportional to the number of acceptable photographs acquired, remaining significantly under 10% error for any model with enough data to render. Furthermore, volumetric stress evaluations were applied using a cross sectional evaluation technique to locate the critical area, and determine the severity of damages. Finally, findings and the accuracy of the results are discussed.

  4. Histopathological analysis of hysterectomy specimens: one year study

    R Baral

    2017-03-01

    Full Text Available Backgound: The uterus is prone to develop several non-neoplastic and neoplastic conditions during the life time of a woman. The aim of this study is to study the histopathological features of varied uterine lesions, their profile and distribution of different lesions in relation of age.Materials and Methods: This is a histopathological database analysis of hysterectomy specimen of one year 2011/12 in Patan Hospital. The variables studied were age and histopathological diagnosis. SPSS version 16 was used as an analytical tool.Results: A total of 3576 histopathology samples were received in this period. There were 1173 gynaecology samples during this period out of which 22% (261 cases were that of hysterectomy. Histopathology diagnosis showed Leiomyoma in 48.6% (127 cases, Adenomyosis was seen in 10.3% (27 cases, Endometrioid Adenocarcinoma was seen in 1.14% (3 cases.Conclusion: A large number of hysterectomy specimens had no significant findings. However, adenomyosis, leiomyomya and adenocarcinoma are also found which may be the cause of abnormal uterine bleeding. 

  5. Correlations between Standard and Miniaturised Charpy-V Specimens

    Lucon, E.; Van Walle, E.; Fabry, A.; Puzzolante, J.-L.; Verstrepen, A.; Vosch, R.; Van de Velde, L.

    1998-12-01

    A total of 565 instrumented impact tests (232 performed on full-size and 333 on sub-size Charpy-V specimens) have been analysed in order to derive meaningful assumptions on the correlations existing between test results obtained on specimens of different size. Nine materials (pressure vessel steels) have been considered, in both as-received and irradiated state, for a total of 19 conditions examined. For the analysis of data, conventional as well novel approaches have been investigated; former ones, based on a review of the existing literature, include predictions of USE values by the use of normalization factors (NF), shifts of index temperatures related to energy/lateral expansion/shear fracture levels, and a combination of both approaches (scaling and shifting of energy curves). More original and recent proposals have also been verified, available in the literature but also proposed by SCK-CEN in the frame of enhanced surveillance of nuclear reactor pressure vessels. Conclusions have been drawn regarding the applicability and reliability of these methodologies, and recommendations have been given for future developments of the activities on this topic

  6. Observation and control of hepatic specimens with MRI and MRS

    Ludescher, B.; Wietek, B.; Machann, J.; Graf, H.; Schick, F.; Subke, J.; Claussen, C.D.

    2004-01-01

    Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with 1 H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weighted images as a band under the liver surface with increasing thickness, penetrating especially fast during the first three days. Spectroscopic measurements revealed the rising formaldehyde concentration in the inner part of the organs. Temperature had no significant influence on the velocity of immersing, but cooling conditions produced less gas-filled caverns due to reduced undesired decomposition processes. Conclusion: The spatial and temporal process of ongoing fixation in the liver can be monitored by MRI. MRS confirms a rising concentration of formaldehyde during ongoing fixation. (orig.) [de

  7. Improving ED specimen TAT using Lean Six Sigma.

    Sanders, Janet H; Karr, Tedd

    2015-01-01

    Lean and Six Sigma are continuous improvement methodologies that have garnered international fame for improving manufacturing and service processes. Increasingly these methodologies are demonstrating their power to also improve healthcare processes. The purpose of this paper is to discuss a case study for the application of Lean and Six Sigma tools in the reduction of turnaround time (TAT) for Emergency Department (ED) specimens. This application of the scientific methodologies uncovered opportunities to improve the entire ED to lab system for the specimens. This case study provides details on the completion of a Lean Six Sigma project in a 1,000 bed tertiary care teaching hospital. Six Sigma's Define, Measure, Analyze, Improve, and Control methodology is very similar to good medical practice: first, relevant information is obtained and assembled; second, a careful and thorough diagnosis is completed; third, a treatment is proposed and implemented; and fourth, checks are made to determine if the treatment was effective. Lean's primary goal is to do more with less work and waste. The Lean methodology was used to identify and eliminate waste through rapid implementation of change. The initial focus of this project was the reduction of turn-around-times for ED specimens. However, the results led to better processes for both the internal and external customers of this and other processes. The project results included: a 50 percent decrease in vials used for testing, a 50 percent decrease in unused or extra specimens, a 90 percent decrease in ED specimens without orders, a 30 percent decrease in complete blood count analysis (CBCA) Median TAT, a 50 percent decrease in CBCA TAT Variation, a 10 percent decrease in Troponin TAT Variation, a 18.2 percent decrease in URPN TAT Variation, and a 2-5 minute decrease in ED registered nurses rainbow draw time. This case study demonstrated how the quantitative power of Six Sigma and the speed of Lean worked in harmony to improve

  8. A proposed standard round compact specimen for plane strain fracture toughness testing

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  9. A Century of Shope Papillomavirus in Museum Rabbit Specimens.

    Clara Escudero Duch

    Full Text Available Sylvilagus floridanus Papillomavirus (SfPV causes growth of large horn-like tumors on rabbits. SfPV was described in cottontail rabbits (probably Sylvilagus floridanus from Kansas and Iowa by Richard Shope in 1933, and detected in S. audubonii in 2011. It is known almost exclusively from the US Midwest. We explored the University of Kansas Natural History Museum for historical museum specimens infected with SfPV, using molecular techniques, to assess if additional wild species host SfPV, and whether SfPV occurs throughout the host range, or just in the Midwest. Secondary aims were to detect distinct strains, and evidence for strain spatio-temporal specificity. We found 20 of 1395 rabbits in the KU collection SfPV symptomatic. Three of 17 lagomorph species (S. nuttallii, and the two known hosts were symptomatic, while Brachylagus, Lepus and eight additional Sylvilagus species were not. 13 symptomatic individuals were positive by molecular testing, including the first S. nuttallii detection. Prevalence of symptomatic individuals was significantly higher in Sylvilagus (1.8% than Lepus. Half of these specimens came from Kansas, though new molecular detections were obtained from Jalisco-Mexico's first-and Nebraska, Nevada, New Mexico, and Texas, USA. We document the oldest lab-confirmed case (Kansas, 1915, pre-dating Shope's first case. SfPV amplification was possible from 63.2% of symptomatic museum specimens. Using multiple methodologies, rolling circle amplification and, multiple isothermal displacement amplification in addition to PCR, greatly improved detection rates. Short sequences were obtained from six individuals for two genes. L1 gene sequences were identical to all previously detected sequences; E7 gene sequences, were more variable, yielding five distinct SfPV1 strains that differing by less than 2% from strains circulating in the Midwest and Mexico, between 1915 and 2005. Our results do not clarify whether strains are host species

  10. Significance of microscopic extention from 1162 esophageal carcinoma specimens

    Wang Jun; Zhu Shuchai; Han Chun; Zhang Xin; Xiao Aiqin; Ma Guoxin

    2007-01-01

    Objective: To examine the subclinical microscopic tumor extention along the long axis in 1162 specimens of esophageal carcinoma so as to help define the clinical target volume(CTV) according to the degree of microscopic extention(ME) for radiotherapy for esophageal carcinoma. Methods: 1162 resected esophageal carcinoma specimens originally located in the neck and thorax were studied with special reference to the correlation between upper and lower resection length from the tumor and positive microscopic margin. Another 52 resected esophageal carcinoma specimens were made into pathological giant sections: the actual resection length of upper and para-esophageal normal tissues was compared with that of the lower nor- mal tissues from the tumor, there by, the ratio of shrinkage was obtained and compared. Results: After fixation, microscopic positive margin ratio of the upper resection border in length ≤0.5 cm group was higher than that in length > 0.5 cm group (16.4% vs 4.1%, P=0.000). Microscopic positive margin ratio of the lower resection border in length ≤1.5 cm group was higher than that in length > 1.5 cm group( 8.1% vs 0.4%, P = 0.000). This showed that the positive margin ratio of the upper border was higher than that of the lower border in resection length > 1.5 cm group(3.5% vs 0.4%, P=0. 000). The actual length of upper and lower normal esophageal tissue after having been made into pathological giant sections in 52 patients, was 30% ± 14% and 44% ± 19% of that measured in the operation. Conclusions: Considering the shrinkage of the normal esophagus during fixation, a CTV margin of 2.0 cm along the upper long axis and 3.5 cm along the lower long axis should be chosen for radiotherapy for esophageal carcinoma, according to the ratio of shrinkage. Ascending invasion proportion is higher than the descending invasion in that tumor. (authors)

  11. Investigation of Asphalt Mixture Creep Behavior Using Thin Beam Specimens

    Zofka, Adam; Marasteanu, Mihai; Turos, Mugur

    2008-01-01

    The asphalt pavement layer consists of two or more lifts of compacted asphalt mixture; the top of the layer is also exposed to aging, a factor that significantly affects the mixture properties. The current testing specifications use rather thick specimens that cannot be used to investigate the gradual change in properties with pavement depth. This paper investigates the feasibility of using the 3-point bending test with thin asphalt mixture beams (127x12.7x6.35 mm) to determine the low-temperature creep compliance of the mixtures. Several theoretical and semi-empirical models, from the theory of composites, are reviewed and evaluated using numerical and experimental data. Preliminary results show that this method can be used for low-temperature mixture characterization but several crucial factors need further inspection and interpretation

  12. Spectrum of histological lesions in 185 consecutive prostatic specimens.

    Mittal B

    1989-07-01

    Full Text Available One hundred and eighty five consecutive prostate specimens were studied. The predominant lesion noted was benign prostatic hyperplasia (B.P.H. (92.97%. The incidence of carcinoma was low, (7.02%. Conditions which can mimic and should be considered in the differential diagnosis of carcinoma, like basal cell hyperplasia, atypical hyperplasia and atrophy associated hyperplasia were noted in 10, 4 and 3 cases of B.P.H. respectively. None of these cases showed evidence of carcinoma. Corpora amylacea were noted in 38.91% of the cases of B.P.H. and were conspicuously absent in cases of carcinoma. Chronic prostatitis was frequently encountered (58% and metaplastic changes were seen in 11% of the cases.

  13. Experimental Behavior of Fatigued Single Stiffener PRSEUS Specimens

    Jegley, Dawn C.

    2009-01-01

    NASA, the Air Force Research Laboratory and The Boeing Company have worked to develop new low-cost, light-weight composite structures for aircraft. A Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept has been developed which offers advantages over traditional metallic structure. In this concept a stitched carbon-epoxy material system has been developed with the potential for reducing the weight and cost of transport aircraft structure by eliminating fasteners, thereby reducing part count and labor. By adding unidirectional carbon rods to the top of stiffeners, the panel becomes more structurally efficient. This combination produces a more damage tolerant design. This document describes the results of experimentation on PRSEUS specimens loaded in unidirectional compression in fatigue and to failure.

  14. Standard practice for preparing, cleaning, and evaluating corrosion test specimens

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers suggested procedures for preparing bare, solid metal specimens for tests, for removing corrosion products after the test has been completed, and for evaluating the corrosion damage that has occurred. Emphasis is placed on procedures related to the evaluation of corrosion by mass loss and pitting measurements. (Warning—In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 1 and 7.2.

  15. Metallographic analysis of irradiated RERTR-3 fuel test specimens

    Meyer, M. K.; Hofman, G. L.; Strain, R. V.; Clark, C. R.; Stuart, J. R.

    2000-01-01

    The RERTR-3 irradiation test was designed to investigate the irradiation behavior of aluminum matrix U-MO alloy dispersion fuels under high-temperature, high-fission-rate conditions. Initial postirradiation examination of RERTR-3 fuel specimens has concentrated on binary U-MO atomized fuels. The rate of matrix aluminum depletion was found to be higher than predictions based on low temperature irradiation data. Wavelength Dispersive X-ray Spectroscopy (WDS) indicates that aluminum is present in the interior of the fuel particles. WDS data is supported by a mass and volume balance calculation performed on the basis of image analysis results. The depletion of matrix aluminum seems to have no detrimental effects on fuel performance under the conditions tested to date

  16. Dual-Energy CT of Rectal Cancer Specimens

    Al-Najami, Issam; Beets-Tan, Regina G H; Madsen, Gunvor

    2016-01-01

    is represented by a certain effective Z value, which allows for information on its composition. OBJECTIVE: We wanted to standardize a method for dual-energy scanning of rectal specimens to evaluate the sensitivity and specificity of benign versus malignant lymph node differentiation. Histopathological evaluation...... cancer. MAIN OUTCOME MEASURES: We measured accuracy of differentiating benign from malignant lymph nodes by investigating the following: 1) gadolinium, iodine, and water concentrations in lymph nodes; 2) dual-energy ratio; 3) dual-energy index; and 4) effective Z value. RESULTS: Optimal discriminations...... between benign and malignant lymph nodes were obtained using the following cutoff values: 1) effective Z at 7.58 (sensitivity, 100%; specificity, 90%; and accuracy, 93%), 2) dual-energy ratio at 1.0 × 10 (sensitivity, 96%; specificity, 87%; and accuracy, 90%), 3) dual-energy index at 0.03 (sensitivity, 97...

  17. Micro Sampling System for Highly Radioactive Specimen by Laser Ablation

    Han, Sun Ho; Ha, Yeong Keong; Han, Ki Chul; Park, Yang Soon; Jee, Kwang Yong; Kim, Won Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2005-03-15

    Shielded laser ablation system composed of laser system, image analyser, XYZ translator with motion controller, ablation chamber, manipulator and various optics was designed. Nd:YAG laser which can be tunable from 1064 nm to 266 nm was selected as light source. CCD camera(< x 200) was chosen to analyze a crater less than 50 un in diameter. XYZ translator was composed of three linear stage which can travel 50 w with a minimum movement of 1 {mu}m and motion controller. Before the performance test, each part of system was optically aligned. To perform the ablation test, the specimen was ablated by 50 {mu}m interval and observed by image analyser The shape of crater was almost round, indicating laser beam has homogeneous energy distribution. The resolution and magnification of image system were compatible with the design.

  18. Signal processing methods for in-situ creep specimen monitoring

    Guers, Manton J.; Tittmann, Bernhard R.

    2018-04-01

    Previous work investigated using guided waves for monitoring creep deformation during accelerated life testing. The basic objective was to relate observed changes in the time-of-flight to changes in the environmental temperature and specimen gage length. The work presented in this paper investigated several signal processing strategies for possible application in the in-situ monitoring system. Signal processing methods for both group velocity (wave-packet envelope) and phase velocity (peak tracking) time-of-flight were considered. Although the Analytic Envelope found via the Hilbert transform is commonly applied for group velocity measurements, erratic behavior in the indicated time-of-flight was observed when this technique was applied to the in-situ data. The peak tracking strategies tested had generally linear trends, and tracking local minima in the raw waveform ultimately showed the most consistent results.

  19. Detection of PCR inhibitors in cervical specimens by using the AMPLICOR Chlamydia trachomatis assay

    R.P.A.J. Verkooyen (Roel); A. Luijendijk (Ad); W.M. Huisman; W.H.F. Goessens (Wil); J.A.J.W. Kluytmans (Jan); J.H. van Rijsoort-Vos; H.A. Verbrugh (Henri)

    1996-01-01

    textabstractTo determine that susceptibility of AMPLICOR Chlamydia trachomatis PCR to inhibitory factors possibly present in cervical specimens, we obtained cervical specimens from 200 gynecology patients attending our outpatient clinic. The prevalence of C. trachomatis

  20. Pseudoangiomatous Stromal Hyperplasia in Core Needle Biopsies of Breast Specimens.

    Kelten Talu, Canan; Boyaci, Ceren; Leblebici, Cem; Hacihasanoglu, Ezgi; Bozkurt, Erol Rustu

    2017-02-01

    Pseudoangiomatous stromal hyperplasia (PASH) is a benign lesion of myofibroblasts that is composed of a network of slit-like channels that resemble vascular spaces. The aims of this study were to document the frequency of PASH in core needle biopsy specimens (CNBS) of the breast, to describe which histopathologic findings coexist with PASH and to examine any endothelial cell differentiation. We reevaluated hematoxylin and eosin-stained sections of all CNBS that were obtained during a 1-year period. First, we performed CD34 and CD31 immunostainings to highlight the areas of PASH, then performed D2-40/podoplanin (lymphatic endothelial marker) and Fli-1 (vascular endothelial cell marker) immunostains. The total number of CNBS was 412. Areas of PASH were noted in 37 of the 412 cases (9%), with a mean age of 38.5 years. The lesions that were described in association with PASH were "benign breast parenchyma with stromal fibrosis" (17/37; 46%), "fibroepithelial tumors" (17/37; 46%), "columnar cell changes (CCC)" (2/37; 5%), and "invasive carcinoma" (1/37; 3%). There were 2 cases of CCC within the foci of PASH (direct contact with PASH), and 8 additional cases of CCC that coexisted in the same specimen but were not in direct contact. There was no staining for D2-40 or Fli-1 within PASH foci. PASH lesions occurred with a frequency of 9% in CNBS and were mostly in association with benign breast lesions in premenopausal women. CCC was determined as an accompanying epithelial lesion within or near PASH areas. No obvious immunopositivity compatible with endothelial cell differentiation was revealed.

  1. Illicit drugs in alternative biological specimens: a case report.

    Margalho, Cláudia; Franco, João; Corte-Real, Francisco; Vieira, Duarte Nuno

    2011-04-01

    Postmortem tissues (e.g. liver, kidney) have been long used in forensic applications especially in those cases where blood is unavailable. The aim of this paper is to demonstrate the importance of the information provided to the forensic toxicologist at the time of carrying out the toxicological analysis, especially in cases where the samples commonly used in forensic toxicology are unavailable. This work describes the toxicological findings in a violent death resulting from a man who was hit by a train. Vitreous humor, liver and kidney were sent for toxicological analysis, once it was not possible to obtain blood and urine. The validated procedures used in the routine casework of Forensic Toxicology Laboratory of the Centre Branch of the National Institute of Legal Medicine, were applied in the analysis of liver, kidney and vitreous humor, using gas chromatography-mass spectrometry after solid-phase extraction and gas chromatography-flame ionization detector for the analysis of drugs of abuse and ethanol, respectively. Morphine, codeine, cocaine, benzoylecgonine and ecgonine methyl ester were found in the liver and in the kidney and no ethanol was found in the vitreous humor. The method validation included the study of specificity, selectivity, limits of detection, recovery and carryover. Although blood and urine are the most common and preferred matrices used for toxicological studies involving drugs of abuse, sometimes the choice of specimen is determined by the case under investigation. The forensic pathologist must be aware that relevant information must be provided so that the toxicological analysis can be conducted in accordance with case history, particularly when the only samples available for analysis are these "unconventional" specimens, since the interpretation of the obtained results is more difficult. Copyright © 2011 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  2. Specimen Machining for the Study of the Effect of Swelling on CGR in PWR Environment.

    Teysseyre, Sebastien Paul [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-06-01

    This report describes the preparation of ten specimens to be used for the study of the effect of swelling on the propagation of irradiation assisted stress corrosion cracking cracks. Four compact tension specimens, four microscopy plates and two tensile specimens were machined from a AISI 304 material that was irradiated up to 33 dpa. The specimens had been machined such as to represent the behavior of materials with 3.7%swelling and <2% swelling.

  3. Effects of Specimen Diameters on the Distribution of Corrosion Fatigue Cracks

    石原, 外美; 塩澤, 和章; 宮尾, 嘉寿

    1988-01-01

    The distribution of corrosion fatigue cracks observed on the un-notched round specimen surface differs with specimen diameter, especially in the low stress amplitude region. At a constant fatigue life ratio, many long cracks are initiated on the larger specimen, 12 mm (diameter), in comparison with the smaller specimen, 6 mm (diameter). On the other hand, in the high stress amplitude region of corrosion fatigue and fatigue in laboratory air, the distribution of cracks during the fatigue proce...

  4. Grips for testing of electrical characteristics of a specimen under a mechanical load

    Briggs, Timothy; Loyola, Bryan

    2018-04-24

    Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

  5. 50 CFR 31.11 - Donation and loan of wildlife specimens.

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Donation and loan of wildlife specimens... of Wildlife Reduction and Disposal § 31.11 Donation and loan of wildlife specimens. Wildlife specimens may be donated or loaned to public institutions for specific purposes. Donation or loans of...

  6. Patient safety in the clinical laboratory: a longitudinal analysis of specimen identification errors.

    Wagar, Elizabeth A; Tamashiro, Lorraine; Yasin, Bushra; Hilborne, Lee; Bruckner, David A

    2006-11-01

    Patient safety is an increasingly visible and important mission for clinical laboratories. Attention to improving processes related to patient identification and specimen labeling is being paid by accreditation and regulatory organizations because errors in these areas that jeopardize patient safety are common and avoidable through improvement in the total testing process. To assess patient identification and specimen labeling improvement after multiple implementation projects using longitudinal statistical tools. Specimen errors were categorized by a multidisciplinary health care team. Patient identification errors were grouped into 3 categories: (1) specimen/requisition mismatch, (2) unlabeled specimens, and (3) mislabeled specimens. Specimens with these types of identification errors were compared preimplementation and postimplementation for 3 patient safety projects: (1) reorganization of phlebotomy (4 months); (2) introduction of an electronic event reporting system (10 months); and (3) activation of an automated processing system (14 months) for a 24-month period, using trend analysis and Student t test statistics. Of 16,632 total specimen errors, mislabeled specimens, requisition mismatches, and unlabeled specimens represented 1.0%, 6.3%, and 4.6% of errors, respectively. Student t test showed a significant decrease in the most serious error, mislabeled specimens (P patient safety projects. Trend analysis demonstrated decreases in all 3 error types for 26 months. Applying performance-improvement strategies that focus longitudinally on specimen labeling errors can significantly reduce errors, therefore improving patient safety. This is an important area in which laboratory professionals, working in interdisciplinary teams, can improve safety and outcomes of care.

  7. 10 CFR 26.159 - Assuring specimen security, chain of custody, and preservation.

    2010-01-01

    ... other entity has reason to question the integrity and identity of the specimens, the specimens may not... identification numbers on the custody-and-control form; (iii) A specimen bottle seal is broken or shows evidence... of the shipping containers are inaccessible without breaking a tamper-evident seal. (g) Couriers...

  8. TESTING OF THE OSCILLATIONS DAMPING CAPABILITY BY EXTERNAL TURNING WITH THE USE OF ALTERNATE BARS IN THE CONSTRUCTION OF THE TURNING TOOL HOLDER

    Marten Madissoo

    2015-09-01

    Full Text Available Modern machinery is highly demanding and the requirement for producing high quality parts is crucial in modern engineering. The most important is the setting of dimensions and tolerances of the surfaces which work together. The shape- and position tolerances may raise the existence of failures and can affect the performance of different machinery. Consequently it is very important that the cutting process is as stable as possible in order to get the best quality parts and to achieve the maximum lifetime of the cutting tool. Unfortunately the machining of complex products from hard materials is accompanied by loss of stability of the cutting process, which leads to tool oscillations, causing an increasing wear of the cutting tools, reducing the lifetime of the machine actuators, which ultimately affects the quality and accuracy of processing responsible products. To avoid this kind of chatter vibrations it is possible to construct specialized cutting tools and tool holder witch reduce this kind of vibrations and can help to increase the manufacturing precision of machine components. In consequence of this the paper focuses on testing the utility effect of a cutting tool holder with alternate bars of different material structure in its construction. The different bars are made from rolled steel and have an anisotropic structure which also has different mechanical properties. This construction is considered as a method to improve the cutting stability of the cutting tool and helps to reduce the oscillations in the finishing turning. The method for the construction of the damper instrument holder with alternate bars is proposed.DOI: http://dx.doi.org/10.5755/j01.ms.21.3.7351

  9. Development and Application of a Sample Holder for In Situ Gaseous TEM Studies of Membrane Electrode Assemblies for Polymer Electrolyte Fuel Cells.

    Kamino, Takeo; Yaguchi, Toshie; Shimizu, Takahiro

    2017-10-01

    Polymer electrolyte fuel cells hold great potential for stationary and mobile applications due to high power density and low operating temperature. However, the structural changes during electrochemical reactions are not well understood. In this article, we detail the development of the sample holder equipped with gas injectors and electric conductors and its application to a membrane electrode assembly of a polymer electrolyte fuel cell. Hydrogen and oxygen gases were simultaneously sprayed on the surfaces of the anode and cathode catalysts of the membrane electrode assembly sample, respectively, and observation of the structural changes in the catalysts were simultaneously carried out along with measurement of the generated voltages.

  10. Altitude Performance Characteristics of Turbojet-engine Tail-pipe Burner with Variable-area Exhaust Nozzle Using Several Fuel Systems and Flame Holders

    Johnson, Lavern A; Meyer, Carl L

    1950-01-01

    A tail-pipe burner with a variable-area exhaust nozzle was investigated. From five configurations a fuel-distribution system and a flame holder were selected. The best configuration was investigated over a range of altitudes and flight Mach numbers. For the best configuration, an increase in altitude lowered the augmented thrust ratio, exhaust-gas total temperature, and tail-pipe combustion efficiency, and raised the specific fuel consumption. An increase in flight Mach number raised the augmented thrust ratio but had no apparent effect on exhaust-gas total temperature, tail-pipe combustion efficiency, or specific fuel consumption.

  11. Electron emission of cathode holder of vacuum diode of an intense electron-beam accelerator and its effect on the output voltage

    Xin-Bing Cheng; Jin-Liang Liu; Hong-Bo Zhang; Zhi-Qiang Hong; Bao-Liang Qian

    2011-01-01

    The vacuum diode which is used to generate relativistic electron beams is one of the most important parts of a pulsed-power modulator. In this paper, the electron emission of cathode holder of a vacuum diode and its effect on the output voltage is investigated by experiments on an intense electron-beam accelerator with 180 ns full width at half maximum and 200–500 kV output voltage. First, the field emission is analyzed and the electric field of the vacuum chamber is calculated. Then, the fla...

  12. Catalog of insect type specimens preserved at the Kunming Institute of Zoology, Chinese Academy of Science with corrections of some specimens.

    Li, Kai-Qin; Wang, Yun-Zhen; Dong, Da-Zhi; Zhang, Li-Kun

    2015-09-18

    This article presents a list of insect types preserved in Kunming Natural History Museum of Zoology (KNHMZ). As of March, 2015, 3 412 type specimens belonging to 266 species/subspecies of 37 families in 9 orders (Odonata, Isoptera, Mantodea, Orthoptera, Hemiptera, Coleoptera, Diptera, Hymenoptera and Lepidoptera) are included. Information corrections of some specimens are provided in this article.

  13. The influence of specimen size on creep crack growth rate in cross-weld CT specimens cut out from a welded component

    Andersson, Peder; Segle, Peter; Samuelson, Lars Aa.

    1999-04-01

    A 3D finite element study of creep crack growth in cross-weld CT specimens with material properties of 2.25Cr1Mo at 550 deg C is carried out, where large strain and displacement theory is used. The creep crack growth rate is calculated using a creep ductility based damage model, in which the creep strain rate perpendicular to the crack plane ahead of the crack tip is integrated, considering the multiaxial stress state. The influence of specimen size on creep crack growth rate under constant load is given special attention, but the possibility to transfer results from cross-weld CT specimens to welded high temperature components is also investigated. The creep crack growth rate of a crack in a circumferentially welded pipe is compared with the creep crack growth rate of cross-weld CT specimens of three different sizes, cut out from the pipe. Although the constraint ahead of the crack tip is higher for a larger CT specimen, the creep crack growth rate is higher for a smaller specimen than for a larger one if they are loaded to attain the same stress intensity factor. If the specimens are loaded to the same C* value, however, a more complicated pattern occurs; depending on the material properties of the weldment constituents, the CT specimen with the intermediate size will either yield the highest or the lowest creep crack growth rate

  14. Prognostic significance of lymphovascular invasion in radical prostatectomy specimens.

    Yee, David S; Shariat, Shahrokh F; Lowrance, William T; Maschino, Alexandra C; Savage, Caroline J; Cronin, Angel M; Scardino, Peter T; Eastham, James A

    2011-08-01

    Study Type - Prognosis (case series). 4. What's known on the subject? and What does the study add? The reported incidence of lymphovascular invasion (LVI) in radical prostatectomy specimens ranges from 5% to 53%. Although LVI has a strong and significant association with adverse clinicopathologic features, it has almost uniformly not been found to be a predictor of biochemical recurrence (BR) on multivariate analysis. This study confirms that LVI is associated with features of aggressive disease and is an independent predictor of BCR. Given that LVI may play a role in the metastatic process, it may be useful in clinical decision-making regarding adjuvant therapy for patients treated with RP. To determine whether lymphovascular invasion (LVI) in radical prostatectomy (RP) specimens has prognostic significance. The study examined whether LVI is associated with clinicopathological characteristics and biochemical recurrence (BCR). LVI was evaluated based on routine pathology reports on 1298 patients treated with RP for clinically localized prostate cancer between 2004 and 2007. LVI was defined as the unequivocal presence of tumour cells within an endothelium-lined space. The association between LVI and clinicopathological features was assessed with univariate logistic regression. Cox regression was used to test the association between LVI and BCR. LVI was identified in 10% (129/1298) of patients. The presence of LVI increased with advancing pathological stage: 2% (20/820) in pT2N0 patients, 16% (58/363) in pT3N0 patients and 17% (2/12) in pT4N0 patients; and was highest in patients with pN1 disease (52%; 49/94). Univariate analysis showed an association between LVI and higher preoperative prostate-specific antigen levels and Gleason scores, and a greater likelihood of extraprostatic extension, seminal vesicle invasion, lymph node metastasis and positive surgical margins (all P < 0.001). With a median follow-up of 27 months, LVI was significantly associated with an

  15. LOCA scenario tests of irradiated fuel rod specimens

    Scott, Harold

    2004-01-01

    Full text: The NRC's cladding performance program at Argonne National Laboratory (ANL) is testing fueled high-burnup segments subjected to LOCA integral phenomena. The data are provided to NRC and the nuclear industry for their independent assessment of the adequacy of licensing criteria for LOCA events. The tests are being conducted with high-burnup 30 cm segments from Limerick (9x9 Zry-2) and H.B. Robinson (15x15 Zry-4) reactors. Prior to testing, sibling samples are characterized with respect to fuel morphology, fuel-cladding bond, cladding oxide layer thickness, hydrogen content and high-temperature steam oxidation kinetics. Specimens that survive quench are subjected to four-point bend tests, followed by local diametral compression tests. The retention of post-quench ductility is a more limiting requirement than surviving thermal stresses during quench. Companion tests are conducted with unirradiated cladding to generate baseline data for comparison with the high-burnup fuel results. LOCA integral tests have the following sequential steps: stabilization of temperature, internal pressure and steam flow at 300 C, ramping of temperature (∼5C/s) through ballooning and burst to 1204 C, hold at 1204 C for 1-5 minutes, slow-cooling (∼3C/s) to 800 C, and water quenching at ∼800C. Two high-burnup tests were completed in 2002 with Limerick BWR rod segments: ramp to burst in argon followed by slow cooling; and the LOCA test with 5-minute hold time at 1204 C, followed by slow cooling. With the exception of burst-opening shape, results for burst temperature, burst pressure, burst length, and ballooning strain profile are more similar to, than different from, results for unirradiated Zry-2 cladding exposed to the same time-temperature history. The 3rd Limerick test with quench was performed in December 2003, and a 4th Limerick test was performed in March 2004. Tests on high-burnup Robinson PWR fuel segments are scheduled to begin in June 2004. The presentation points

  16. Specimen preparation of irradiated materials for examination in the atom probe field ion microscope

    Russell, K.F.; Miller, M.K.

    1994-01-01

    The atom probe field ion microscope (APFIM) requires specimens in the form of ultrasharp needles. Basic protective measures used to reduce exposure druing specimen preparation are discussed. The low-level radioactive specimen blanks may be made using a two-stage electropolishing process using a thin layer of electrolyte floating on a denser inert liquid; this produces a necked region and eventually two specimens from each single blank. The amount of material handled may also be reduced using a micropolishing technique to repolish blunt or fractured specimens. Control of contamination and possible spills is discussed

  17. A test specimen for characterizing the fracture energy of interfaces in composites

    Shaw, L.; Abbaschian, R.

    1993-01-01

    A sandwich-type chevron-notched specimen, which has a phase angle of loading near zero, is proposed to measure interfacial fracture energy arising mainly from chemical bonding. With the specimen configuration of this kind, the advantages from both sandwich test specimens and chevron-notched specimens can be combined to provide an easy and accurate test for the measurement of interfacial fracture energy. The validity of the specimen has been analyzed in terms of the mechanics of sandwich-type specimens and chevron-notched specimens, and demonstrated using the Al 2 O 3 /Nb bimaterial system. The results show that for a phase angle of loading around -7 degrees the Al 2 O 3 /Nb interface has a fracture energy of 9.3 ± 0.2 J/m 2 . 39 refs

  18. Methods and devices for small specimen testing at the Japan Atomic Energy Research Institute

    Jitsukawa, Shiro; Kizaki, Minoru; Umino, Akira; Shiba, Kiyoyuki; Hishinuma, Akimichi

    1993-01-01

    Devices for a punch test on annular notched specimens, small punch (SP) tests, and miniaturized tension tests in hot cells were developed. A micro-manipulator to handle small specimens and an electro-discharge machine (EDM) to extract miniaturized tension specimens and annular notched specimens from transmission electron microscopy (TEM) disks were also fabricated. These devices were designed and made for remote operation in hot cells. Preliminary tests to evaluate the applicability of test methods were carried out. Correlation between SP test results and tensile properties was not strong. Miniaturized tensile results were reasonably similar to the results with larger specimens. The ductile-brittle transition temperature (DBTT) by the punch test on annular notched specimens was higher than that obtained from the SP test. However, materials dependence of the DBTT was different from that measured by standard Charpy V-notch (CVN) tests. This may be due to a specimen size effect

  19. A new shape specimens determined the J1c value of nuclear pressure vessel steel

    Xu, W.Q.

    1989-01-01

    The J integral has two basic definitions, a two-dimensional energy line integral definition and an energy rate definition. The line integral definition cannot be used for this experimental determination. The energy rate definition can be used but the procedure is somewhat laborious. Methods were developed for more easily determining J by approximation formulas. The first of these were where J could be estimated with reasonable accuracy for a deeply cracked bend-type specimen. This method is slightly inaccurate. This paper is concerned with a new shape specimen. It is called the W-shape specimen. The W-shape specimens are smaller volume than the compact specimens. It is convenient to operate the W-shape specimens in hot cell. It can be put into surveillance capsules and can also do specimen irradiation in engineering test reactor

  20. Herbarium specimens show contrasting phenological responses to Himalayan climate.

    Hart, Robbie; Salick, Jan; Ranjitkar, Sailesh; Xu, Jianchu

    2014-07-22

    Responses by flowering plants to climate change are complex and only beginning to be understood. Through analyses of 10,295 herbarium specimens of Himalayan Rhododendron collected by plant hunters and botanists since 1884, we were able to separate these responses into significant components. We found a lack of directional change in mean flowering time over the past 45 y of rapid warming. However, over the full 125 y of collections, mean flowering time shows a significant response to year-to-year changes in temperature, and this response varies with season of warming. Mean flowering advances with annual warming (2.27 d earlier per 1 °C warming), and also is delayed with fall warming (2.54 d later per 1 °C warming). Annual warming may advance flowering through positive effects on overwintering bud formation, whereas fall warming may delay flowering through an impact on chilling requirements. The lack of a directional response suggests that contrasting phenological responses to temperature changes may obscure temperature sensitivity in plants. By drawing on large collections from multiple herbaria, made over more than a century, we show how these data may inform studies even of remote localities, and we highlight the increasing value of these and other natural history collections in understanding long-term change.

  1. West Nile Virus lineage-2 in Culex specimens from Iran.

    Shahhosseini, Nariman; Chinikar, Sadegh; Moosa-Kazemi, Seyed Hassan; Sedaghat, Mohammad Mehdi; Kayedi, Mohammad Hassan; Lühken, Renke; Schmidt-Chanasit, Jonas

    2017-10-01

    Screening of mosquitoes for viruses is an important forecasting tool for emerging and re-emerging arboviruses. Iran has been known to harbour medically important arboviruses such as West Nile virus (WNV) and dengue virus (DENV) based on seroepidemiological data. However, there are no data about the potential mosquito vectors for arboviruses in Iran. This study was performed to provide mosquito and arbovirus data from Iran. A total of 32 317 mosquitos were collected at 16 sites in five provinces of Iran in 2015 and 2016. RT-PCR for detection of flaviviruses was performed. The PCR amplicons were sequenced, and 109 WNV sequences, including one obtained in this study, were used for phylogenetic analyses. The 32 317 mosquito specimens belonging to 25 species were morphologically distinguished and distributed into 1222 pools. Culex pipiens s.l. comprised 56.429%. One mosquito pool (0.08%), containing 46 unfed Cx. pipiens pipiens form pipiens (Cpp) captured in August 2015, was positive for flavivirus RNA. Subsequent sequencing and phylogenetic analyses revealed that the detected Iranian WNV strain belongs to lineage 2 and clusters with a strain recently detected in humans. No flaviviruses other than WNV were detected in the mosquito pools. Cpp could be a vector for WNV in Iran. Our findings indicate recent circulation of WNV lineage-2 strain in Iran and provide a solid base for more targeted arbovirus surveillance programs. © 2017 John Wiley & Sons Ltd.

  2. Self-heating forecasting for thick laminate specimens in fatigue

    Lahuerta, F.; Westphal, T.; Nijssen, R. P. L.

    2014-12-01

    Thick laminate sections can be found from the tip to the root in most common wind turbine blade designs. Obtaining accurate and reliable design data for thick laminates is subject of investigations, which include experiments on thick laminate coupons. Due to the poor thermal conductivity properties of composites and the material self-heating that occurs during the fatigue loading, high temperature gradients may appear through the laminate thickness. In the case of thick laminates in high load regimes, the core temperature might influence the mechanical properties, leading to premature failures. In the present work a method to forecast the self-heating of thick laminates in fatigue loading is presented. The mechanical loading is related with the laminate self-heating, via the cyclic strain energy and the energy loss ratio. Based on this internal volumetric heat load a thermal model is built and solved to obtain the temperature distribution in the transient state. Based on experimental measurements of the energy loss factor for 10mm thick coupons, the method is described and the resulting predictions are compared with experimental surface temperature measurements on 10 and 30mm UD thick laminate specimens.

  3. Three-Dimensional scanning transmission electron microscopy of biological specimens

    De Jonge, Niels

    2010-01-18

    A three-dimensional (3D) reconstruction of the cytoskeleton and a clathrin-coated pit in mammalian cells has been achieved from a focal-series of images recorded in an aberration-corrected scanning transmission electron microscope (STEM). The specimen was a metallic replica of the biological structure comprising Pt nanoparticles 2-3 nm in diameter, with a high stability under electron beam radiation. The 3D dataset was processed by an automated deconvolution procedure. The lateral resolution was 1.1 nm, set by pixel size. Particles differing by only 10 nm in vertical position were identified as separate objects with greater than 20% dip in contrast between them. We refer to this value as the axial resolution of the deconvolution or reconstruction, the ability to recognize two objects, which were unresolved in the original dataset. The resolution of the reconstruction is comparable to that achieved by tilt-series transmission electron microscopy. However, the focal-series method does not require mechanical tilting and is therefore much faster. 3D STEM images were also recorded of the Golgi ribbon in conventional thin sections containing 3T3 cells with a comparable axial resolution in the deconvolved dataset. © 2010 Microscopy Society of America.

  4. Hydrogen embrittlement of titanium tested with fracture mechanics specimens

    Aho-Mantila, I.; Rahko, P.

    1990-11-01

    Titanium is one of the possible canister materials for spent nuclear fuel. The aim of this study is to determine whether the hydrogen embrittlement of titanium could be a possible deterioration mechanism of titanium canisters. This experimental study was preceded by a literature review and an experimental study on crack nucleation. Tests in this study were carried out with hydrogen charged fracture mechanics specimens. The studied hydrogen contents were as received, 100 ppm, 200 ppm, 500 ppm and 700 ppm and the types of the studied titanium were ASTM Grades 2 and 12. Test methods were slow tensile test (0.027 mm/h) and fatigue test (stress ratio 0.7 or 0.8 and frequency 5 Hz). According to the literature titanium may be embrittled by hydrogen at slow strain rates and cracking may occur under sustained load. In this study no evidence of hydrogen embrittlement was noticed in slow strain rate tension with bulk hydrogen contents up to 700 ppm. The fatigue tests of titanium Grades 2 and 12 containing 700 ppm hydrogen showed even slower crack growth compared to the as received condition. Very high hydrogen contents well in eccess of 700 ppm on the surface of titanium can, however, facilitate surface crack nucleation and crack growth, as shown in the previous study

  5. Morphological variants of renal carcinoma in radical nephrectomy specimens

    Humera, A.; Kehar, I.

    2015-01-01

    To determine the morphological variants of Renal Cell Carcinoma (RCC) to detect the commonest histopathological type with special focus to the newly introduced entity Clear Cell Papillary Renal Cell Carcinoma (CCPRCC). Study Design: Case series. Place and Duration of Study: Department of Pathology, Basic Medical Sciences Institute, JPMC, Karachi, from January 2007 to December 2012. Methodology: Paraffin embedded blocks of 32 cases of radical nephrectomy specimens for renal mass were selected from records of Pathology Department, BMSI. Cases were excluded due to inadequate biopsies. Remaining 30 cases of renal cell carcinoma were included in study. H and E staining was done for all cases and PAS stain was employed for a few cases. All cases were reviewed under light microscope. Results: The 30 cases of renal cell carcinoma included 21 (70%) clear cell renal cell carcinoma, 03 (10%) clear cell papillary renal cell carcinoma, 02 (6.6%) papillary renal cell carcinoma and 04 (13.33%) hybrid tumors. Majority of cases (53.3%) found in age range between 40 - 60 years while 23.33% cases were found in 7th and 6.6% in 8th decade of life. While 16.66% cases were in younger age group that is between 31 - 40 years of age. Sixty percent cases of right radical nephrectomies and 40% cases of left radical nephrectomies. Conclusion: CCRCC was most common histopathologic type followed by CCPRCC, hybrid tumors and PRCC. (author)

  6. Classification of breast cancer cytological specimen using convolutional neural network

    Żejmo, Michał; Kowal, Marek; Korbicz, Józef; Monczak, Roman

    2017-01-01

    The paper presents a deep learning approach for automatic classification of breast tumors based on fine needle cytology. The main aim of the system is to distinguish benign from malignant cases based on microscopic images. Experiment was carried out on cytological samples derived from 50 patients (25 benign cases + 25 malignant cases) diagnosed in Regional Hospital in Zielona Góra. To classify microscopic images, we used convolutional neural networks (CNN) of two types: GoogLeNet and AlexNet. Due to the very large size of images of cytological specimen (on average 200000 × 100000 pixels), they were divided into smaller patches of size 256 × 256 pixels. Breast cancer classification usually is based on morphometric features of nuclei. Therefore, training and validation patches were selected using Support Vector Machine (SVM) so that suitable amount of cell material was depicted. Neural classifiers were tuned using GPU accelerated implementation of gradient descent algorithm. Training error was defined as a cross-entropy classification loss. Classification accuracy was defined as the percentage ratio of successfully classified validation patches to the total number of validation patches. The best accuracy rate of 83% was obtained by GoogLeNet model. We observed that more misclassified patches belong to malignant cases.

  7. On impact testing of subsize Charpy V-notch type specimens

    Mikhail, A.S.; Nanstad, R.K.

    1994-01-01

    The potential for using subsize specimens to determine the actual properties of reactor pressure vessel steels is receiving increasing attention for improved vessel condition monitoring that could be beneficial for light-water reactor plant-life extension. This potential is made conditional upon, on the one hand, by the possibility of cutting samples of small volume from the internal surface of the pressure vessel for determination of actual properties of the operating pressure vessel. The plant-life extension will require supplemental surveillance data that cannot be provided by the existing surveillance programs. Testing of subsize specimens manufactured from broken halves of previously tested surveillance Charpy V-notch (CVN) specimens offers an attractive means of extending existing surveillance programs. Using subsize CVN type specimens requires the establishment of a specimen geometry that is adequate to obtain a ductile-to-brittle transition curve similar to that obtained from full-size specimens. This requires the development of a correlation of transition temperature and upper-shelf toughness between subsize and full-size specimens. The present study was conducted under the Heavy-Section Steel Irradiation Program. Different published approaches to the use of subsize specimens were analyzed and five different geometries of subsize specimens were selected for testing and evaluation. The specimens were made from several types of pressure vessel steels with a wide range of yield strengths, transition temperatures, and upper-shelf energies (USEs). Effects of specimen dimensions, including depth, angle, and radius of notch have been studied. The correlation of transition temperature determined from different types of subsize specimens and the full-size specimen is presented. A new procedure for transforming data from subsize specimens was developed and is presented

  8. Is a 10-sow unit economically sustainable? A profitability assessment of productivity amongst small-holder pig farmers, Mpumalanga, South Africa.

    Munzhelele, Priscilla; Oguttu, James W; Fasina, Folorunso O

    2016-05-12

    The majority of small-holder pig farmers in Mpumalanga had between 1- and 10-sow herds. The main aim of this study is to evaluate the current government agricultural intervention (supply of 10 sows and a boar) in terms of technical and economic feasibilities and ascertain whether the small-scale pig value chain system alleviates poverty. Data were obtained from 220 randomly selected small-holder pig farmers using a semi-structured questionnaire. The results showed that 58% farrowed ≤ 10 piglets/born/sow/litter, 44.2% practiced no weaning method and many fed swill and leftovers alone (41.6%). Pair-wise association revealed that the feeding of commercial feeds had a relationship with pigs in relatively good to very good body condition. Pigs in poor body condition were positively correlated with the feeding of swill alone. The economic models for the 10-sow unit proved that pig farming is unprofitable if the current management and feeding systems that operate in the commercial industry are utilised. However, only through a combination of cooperative systems, benefits of economies of scale, reduction of preweaning mortalities and structured government inputs can pig production be profitable at this scale of production.

  9. Is a 10-sow unit economically sustainable? A profitability assessment of productivity amongst small-holder pig farmers, Mpumalanga, South Africa

    Priscilla Munzhelele

    2016-05-01

    Full Text Available The majority of small-holder pig farmers in Mpumalanga had between 1- and 10-sow herds. The main aim of this study is to evaluate the current government agricultural intervention (supply of 10 sows and a boar in terms of technical and economic feasibilities and ascertain whether the small-scale pig value chain system alleviates poverty. Data were obtained from 220 randomly selected small-holder pig farmers using a semi-structured questionnaire. The results showed that 58% farrowed ≤ 10 piglets/born/sow/litter, 44.2% practiced no weaning method and many fed swill and leftovers alone (41.6%. Pair-wise association revealed that the feeding of commercial feeds had a relationship with pigs in relatively good to very good body condition. Pigs in poor body condition were positively correlated with the feeding of swill alone. The economic models for the 10-sow unit proved that pig farming is unprofitable if the current management and feeding systems that operate in the commercial industry are utilised. However, only through a combination of cooperative systems, benefits of economies of scale, reduction of preweaning mortalities and structured government inputs can pig production be profitable at this scale of production. Keywords: piglets; market; profit; economics; feeds

  10. Social Perception of Hydrogen Technologies: The View of Spanish Stake holders; Percepcion Social de las Tecnologias del Hidrogeno. La Vision de los Stakeholders Espanoles

    Ferri Anglada, S.

    2013-07-01

    This technical report presents an overview of the social perception and vision of a sample of Spanish stake holders on hydrogen technologies. The study is based on the implementation of a survey, combining both quantitative and qualitative data. An ad hoc electronic survey was design to collect views and perceptions on several key factors regarding this innovative energy alternative. The group of experts participating (N=130) in the study, comes mainly from research centers, universities and private companies. The survey addresses three major themes: expert views, social acceptability, and contextual factors of hydrogen technologies. The aim is to capture both the current and the future scene as viewed by the experts on hydrogen technologies, identifying key factors in terms of changes, uncertainties, obstacles and opportunities. The objective is to identify potential key features for the introduction, development, promotion, implementation, and large-scale deployment of a highly successful energy proposal in countries such as Iceland, one of the pioneers in base its economy on hydrogen technologies. To conclude, this report illustrates the positive engagement of a sample of Spanish stake holders towards hydrogen technologies that may prove vital in the transition towards the Hydrogen Economy in Spain. (Author)

  11. Robotic Transnasal Endoscopic Skull Base Surgery: Systematic Review of the Literature and Report of a Novel Prototype for a Hybrid System (Brescia Endoscope Assistant Robotic Holder).

    Bolzoni Villaret, Andrea; Doglietto, Francesco; Carobbio, Andrea; Schreiber, Alberto; Panni, Camilla; Piantoni, Enrico; Guida, Giovanni; Fontanella, Marco Maria; Nicolai, Piero; Cassinis, Riccardo

    2017-09-01

    Although robotics has already been applied to several surgical fields, available systems are not designed for endoscopic skull base surgery (ESBS). New conception prototypes have been recently described for ESBS. The aim of this study was to provide a systematic literature review of robotics for ESBS and describe a novel prototype developed at the University of Brescia. PubMed and Scopus databases were searched using a combination of terms, including Robotics OR Robot and Surgery OR Otolaryngology OR Skull Base OR Holder. The retrieved papers were analyzed, recording the following features: interface, tools under robotic control, force feedback, safety systems, setup time, and operative time. A novel hybrid robotic system has been developed and tested in a preclinical setting at the University of Brescia, using an industrial manipulator and readily available off-the-shelf components. A total of 11 robotic prototypes for ESBS were identified. Almost all prototypes present a difficult emergency management as one of the main limits. The Brescia Endoscope Assistant Robotic holder has proven the feasibility of an intuitive robotic movement, using the surgeon's head position: a 6 degree of freedom sensor was used and 2 light sources were added to glasses that were therefore recognized by a commercially available sensor. Robotic system prototypes designed for ESBS and reported in the literature still present significant technical limitations. Hybrid robot assistance has a huge potential and might soon be feasible in ESBS. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Operative outcomes of conventional specimen radiography versus in-operating room specimen radiography in radioactive seed-localized segmental mastectomies.

    Rhee, Daniel; Pockaj, Barbara; Wasif, Nabil; Stucky, Chee-Chee; Pizzitola, Victor; Giurescu, Marina; Patel, Bhavika; McCarthy, Janice; Gray, Richard

    2018-01-01

    In-operating room specimen radiography (ORSR) has not been studied among women undergoing radioactive seed localization (RSL) for breast cancer surgery and had the potential to decrease operative time and perhaps improve intraoperative margin management. One hundred consecutive RSL segmental mastectomies among 98 patients using ORSR were compared to 100 consecutive segmental mastectomies among 98 patients utilizing conventional radiography (CSR) prior to the initiation of ORSR from December 2013 to January 2015 after radioactive seed localization. Final pathologic margins were considered to be 10 mm for all cases of no residual disease after biopsy or neoadjuvant therapy, but such patients were excluded from analyses involving tumor size. All patients' specimens were subjected to intraoperative pathologic consultation in addition to ORSR or CSR. The median age of the cohort was 65 years (range 36-97), and the median tumor size was 1 cm. There were no differences between the ORSR and CSR groups in age, tumor size, percentage of cases with only DCIS, and percentage of cases with microcalcifications. The ORSR group had a statistically significant lower BMI. Mean operative time from cut-to-close was not significantly different (ORSR 77 min, SD 24.8 vs CSR 76 min, SD 24.8, p = 0.75). There was no statistical difference in mean closest final pathologic margin (4.99 mm, SD 3.3 vs 4.88 mm, SD 3.5, p = 0.9). The percentage undergoing intraoperative margin re-excision (ORSR 40%, CR 47%, p = 0.31) and the mean total number of margins excised intraoperatively (ORSR 0.9, CR 1.0 p = 0.65) were similar. The rate of any margin CSR; this difference was not statistically significant (p = 0.25). The mean ratio of segmental mastectomy volume to maximum tumor diameter was less for ORSR (82.7cm2 vs 139.4cm2, p = 0.014). ORSR for RSL breast surgery, in the setting of routine intraoperative pathology consultation, does not significantly impact operative time, the rate or

  13. Fusidic acid resistance among staphylococci strains isolated from clinical specimens

    Özcan Deveci

    2012-03-01

    Full Text Available Objectives: The aim of this study was to investigate in vitrosusceptibility of fusidic acid to clinic isolates of staphylococci.Materials and methods: The forty-one coagulase negativestaphylococci (CNS and 18 Staphylococcus aureusstrains isolated from various clinical specimens were includedin this study. Staphylococci isolates were identifiedby conventional methods such as colony morphologyonto medium, gram staining, catalase and coagulasetests. According to “Clinical and Laboratory Standards Institute(CLSI” criteria, antimicrobial susceptibility testingof isolates was performed by Kirby-Bauer’s disk diffusionmethod.Results: The seventy-two percent of the isolated S.aureuswere defined as methicillin sensitive-S.aureus (MSSA,28% of the isolated S.aureus were defined as methicillinresistant-S.aureus (MRSA. The difference among fusidicacid susceptibility rates of MSSA and MRSA strains wasnot statistically significant (p=0.305. The twenty-nine percentof the isolated CNS were defined as methicillin sensitive-CNS (MS-CNS, 71% of the isolated CNS were definedas methicillin resistant-CNS (MR-CNS. There wasno statistically significant difference between MS-CNSand MR-CNS strains for fusidic acid susceptibility rates(p=0.490. But the difference among fusidic acid susceptibilityrates of CNS and S.aureus strains was statisticallysignificant (p<0.001. CNS strains were found more resistancethan S.aureus strains for fusidic acid.Conclusion: In this study, the resistance rates weredetected to increase for fusidic acid along with methicillinresistance. Among CNS isolates, fusidic acid resistancerates were significantly more elevated than that forS.aureus. Fusidic acid remains as an alternative in thetreatment of infections due to staphylococci.

  14. Does stoma site specimen extraction increase postoperative ileostomy complication rates?

    Li, Wanglin; Benlice, Cigdem; Stocchi, Luca; Kessler, Hermann; Gorgun, Emre; Costedio, Meagan

    2017-09-01

    Minimizing incisions has the potential to decrease hernia formation and wound complications following laparoscopic surgery. It is currently unknown if using the stoma site for specimen extraction affects outcomes. This study aims to evaluate the impact of stoma site extraction on postoperative complication rates in laparoscopic colorectal surgery. After IRB approval, a retrospective comparative review of 738 consecutive patients (405 M) who underwent laparoscopic colorectal surgery with ileostomy between January 2008 and December 2014 was performed. Patients who had a minimally invasive surgery that required an ileostomy were included. Patients were classified into two groups: stoma site extraction (SSE) or non-stoma site extraction (NSSE) and compared by body mass index (BMI), age, comorbidities, American Society of Anesthesiologists score, length of stay, estimated blood loss, parastomal complications, and hernia rate. The parastomal hernia rate was 10.1% for the SSE group (n = 14) and 4.2% for the NSSE group (n = 25) (p = 0.007). The need for additional surgeries was 7/139 (5.0%) for the SSE group and 27/599 (4.5%) for the NSSE group (p = 0.79). There was no difference in the hernia rate after stoma closure in either group. There was no difference in single incision laparoscopic surgery versus conventional laparoscopy or robotic-assisted laparoscopy on stoma site complications in patients with SSE. SSE, transfusion, and BMI >30 were found to be independent factors associated with increased stoma site complications. SSE does increase stoma site complications. SSE should be used with caution, or in conjunction with other techniques to reduce hernias in patients requiring a permanent stoma or with an elevated BMI. The increase in stoma site complications does not translate into additional surgeries or postoperative sequelae following stoma reversal and is a reasonable option in patients requiring a temporary stoma.

  15. Tension test system for irradiated small specimens operated by remote control

    Okada, Akira

    1993-01-01

    A robot-based tension test system has been developed to aid in the mechanical testing of highly radioactive specimens. This system reduces radiation hazards from specimens and allows for the uniform precision of testing results independent of experimenters' skills. The robot system is designed to accommodate a miniaturized tension specimen with a gage section 5.5 by 1.2 mm, with a total length and width of 12.5 and 2.3 mm, respectively, and thickness of about 0.2 mm. The system is composed of a manipulating robot, a vibrational-type specimen feeder, a rotating-type specimen tray, a specimen observation system, a simulated tension text fixture, and a microcomputer for controlling the system. This system accomplishes specimen arrangement in the specimen tray, specimen transportation and loading to the test fixture and testing, and removal of the broken specimen from the fixture. These procedures are performed quickly, safely, and with uniform testing precision by computer control remotely by an unskilled experimenter

  16. Role of specimen US for predicting resection margin status in breast conserving therapy.

    Moschetta, M; Telegrafo, M; Introna, T; Coi, L; Rella, L; Ranieri, V; Cirili, A; Stabile Ianora, A A; Angelelli, G

    2015-01-01

    To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.

  17. Finite element simulations of electrostatic dopant potentials in thin semiconductor specimens for electron holography

    Somodi, P.K.; Twitchett-Harrison, A.C.; Midgley, P.A. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Kardynał, B.E. [Peter Grünberg Institute 9, Forschungszentrum Jülich, D-52425 Jülich (Germany); Barnes, C.H.W. [Department of Physics, University of Cambridge, Madingley Road, Cambridge CB3 0HE (United Kingdom); Dunin-Borkowski, R.E., E-mail: rafaldb@gmail.com [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute 5, Forschungszentrum Jülich, D-52425 Jülich (Germany)

    2013-11-15

    Two-dimensional finite element simulations of electrostatic dopant potentials in parallel-sided semiconductor specimens that contain p–n junctions are used to assess the effect of the electrical state of the surface of a thin specimen on projected potentials measured using off-axis electron holography in the transmission electron microscope. For a specimen that is constrained to have an equipotential surface, the simulations show that the step in the projected potential across a p–n junction is always lower than would be predicted from the properties of the bulk device, but is relatively insensitive to the value of the surface state energy, especially for thicker specimens and higher dopant concentrations. The depletion width measured from the projected potential, however, has a complicated dependence on specimen thickness. The results of the simulations are of broader interest for understanding the influence of surfaces and interfaces on electrostatic potentials in nanoscale semiconductor devices. - Highlights: • Finite element simulations are performed to calculate electrostatic dopant potentials in TEM specimens that contain p–n junctions. • The effect of the electrical state of the specimen surface on the projected potential is assessed for equipotential specimen surfaces. • The step in projected potential is always found to be lower than the step in potential in the bulk device. • The step in projected potential is least sensitive to surface state energy for thicker specimens and higher dopant concentrations. • The depletion width measured from the projected potential has a complicated dependence on specimen thickness.

  18. Finite element simulations of electrostatic dopant potentials in thin semiconductor specimens for electron holography

    Somodi, P.K.; Twitchett-Harrison, A.C.; Midgley, P.A.; Kardynał, B.E.; Barnes, C.H.W.; Dunin-Borkowski, R.E.

    2013-01-01

    Two-dimensional finite element simulations of electrostatic dopant potentials in parallel-sided semiconductor specimens that contain p–n junctions are used to assess the effect of the electrical state of the surface of a thin specimen on projected potentials measured using off-axis electron holography in the transmission electron microscope. For a specimen that is constrained to have an equipotential surface, the simulations show that the step in the projected potential across a p–n junction is always lower than would be predicted from the properties of the bulk device, but is relatively insensitive to the value of the surface state energy, especially for thicker specimens and higher dopant concentrations. The depletion width measured from the projected potential, however, has a complicated dependence on specimen thickness. The results of the simulations are of broader interest for understanding the influence of surfaces and interfaces on electrostatic potentials in nanoscale semiconductor devices. - Highlights: • Finite element simulations are performed to calculate electrostatic dopant potentials in TEM specimens that contain p–n junctions. • The effect of the electrical state of the specimen surface on the projected potential is assessed for equipotential specimen surfaces. • The step in projected potential is always found to be lower than the step in potential in the bulk device. • The step in projected potential is least sensitive to surface state energy for thicker specimens and higher dopant concentrations. • The depletion width measured from the projected potential has a complicated dependence on specimen thickness

  19. Tensile tests and metallography of brazed AISI 316L specimens after irradiation

    Groot, P.; Franconi, E.

    1994-01-01

    Stainless steel type 316L tensile specimens were vacuum brazed with three kinds of alloys: BNi-5, BNi-6, and BNi-7. The specimens were irradiated up to 0.7 dpa at 353 K in the High Flux Reactor at JRC Petten, the Netherlands. Tensile tests were performed at a constant displacement rate of 10 -3 s -1 at room temperature in the ECN hot cell facility. BNi-5 brazed specimens showed ductile behaviour. Necking and fractures were localized in the plate material. BNi-6 and BNi-7 brazed specimens failed brittle in the brazed zone. This was preceded by uniform deformation of the plate material. Tensile test results of irradiated specimens showed higher stresses due to radiation hardening and a reduction of the elongation of the plate material compared to the reference. SEM examination of the irradiated BNi-6 and BNi-7 fracture surfaces showed nonmetallic phases. These phases were not found in the reference specimens. ((orig.))

  20. Development of piezoelectric ceramics driven fatigue testing machine for small specimens

    Saito, S.; Kikuchi, K.; Onishi, Y.; Nishino, T.

    2002-01-01

    A new fatigue testing machine with piezoelectric ceramics actuators was developed and a prototype was manufactured for high-cycle fatigue tests with small specimens. The machine has a simple mechanism and is compact. These features make it easy to set up and to maintain the machine in a hot cell. The excitation of the actuator can be transmitted to the specimen using a lever-type testing jig. More than 100 μm of displacement could be prescribed precisely to the specimen at a frequency of 50 Hz. This was sufficient performance for high-cycle bend fatigue tests on specimens irradiated at the SINQ target in Paul Scherrer Institute. The relationship of a displacement applied to the specimen and the strain of the necking part were obtained by experimental methods and by finite element method (FEM) calculations. Both results showed good agreement. This fact makes it possible to evaluate the strain of irradiated specimens by FEM simulations