WorldWideScience

Sample records for specific diagnostic test

  1. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Guogen Shan

    2015-01-01

    Full Text Available Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003. However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization.

  2. Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.

    Science.gov (United States)

    Papa, Frank J.; Schumacker, Randall E.

    Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…

  3. Diagnostic Value of ELISA Tests for the Detection of Specific Antibodies in Cats and Rabbits with Dermatophytosis

    Directory of Open Access Journals (Sweden)

    Marinka Drobnič-Košorok

    2002-01-01

    Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.

  4. Development of a Culture Specific Critical Thinking Ability Test and Using It as a Supportive Diagnostic Test for Giftedness

    Science.gov (United States)

    Köksal, Mustafa Serdar

    2016-01-01

    The purposes of this study were to develop a culture specific critical thinking ability test for 6, 7, and 8. grade students in Turkey and to use it as an assessment instrument for giftedness. For these purposes, item pool involving 22 items was formed by writing items focusing on the current and common events presented in (Turkish) media from…

  5. Diagnostic value of scratch-chamber test, skin prick test, histamine release and specific IgE in birch-allergic patients with oral allergy syndrome to apple

    DEFF Research Database (Denmark)

    Osterballe, M; Scheller, R; Stahl Skov, P

    2003-01-01

    BACKGROUND: The aim of the study was to examine the diagnostic value of skin prick test (SPT), scratch-chamber test (SCT), histamine release (HR) and specific immunoglobulin E (IgE) in birch-allergic patients with oral allergy syndrome to apple. METHODS: Ten birch-allergic patients with oral...... a detailed case history about symptoms of oral allergy syndrome combined with a SPT with fresh apple peel or A72 will be useful....

  6. 1968 Prototype Diagnostic Test.

    Science.gov (United States)

    Veterans Administration Hospital, Bedford, MA.

    This true-false diagnostic test was used for pretesting of employees at a Veterans Administration Hospital. The test is comprised of 20 items. An alternate test--Classification Questionnaire--was used for testing after remedial training. (For related document, see TM 002 334.) (DB)

  7. Prenatal Genetic Diagnostic Tests

    Science.gov (United States)

    ... are available for many inherited disorders. The main disadvantage is that diagnostic testing carries a very small ... chromosomes, arranged in order of size. Microarray: A technology that examines all of a person’s genes to ...

  8. Substitution of Pichia pastoris-derived recombinant proteins with mannose containing O- and N-linked glycans decreases specificity of diagnostic tests

    NARCIS (Netherlands)

    van Oort, Erica; Lerouge, Patrice; de Heer, Pleuni G.; Séveno, Martial; Coquet, Laurent; Modderman, Piet W.; Faye, Loïc; Aalberse, Rob C.; van Ree, Ronald

    2004-01-01

    Background: Recombinant proteins from Pichia pastoris need to be fully evaluated before used as diagnostic tools. Objective: The objective of this study was to investigate whether glycosylation by P. pastoris interferes with the specificity of diagnostic tests. Methods: An autoantigen involved in

  9. Diagnosis of asthma: diagnostic testing.

    Science.gov (United States)

    Brigham, Emily P; West, Natalie E

    2015-09-01

    Asthma is a heterogeneous disease, encompassing both atopic and non-atopic phenotypes. Diagnosis of asthma is based on the combined presence of typical symptoms and objective tests of lung function. Objective diagnostic testing consists of 2 components: (1) demonstration of airway obstruction, and (2) documentation of variability in degree of obstruction. A review of current guidelines and literature was performed regarding diagnostic testing for asthma. Spirometry with bronchodilator reversibility testing remains the mainstay of asthma diagnostic testing for children and adults. Repetition of the test over several time points may be necessary to confirm airway obstruction and variability thereof. Repeated peak flow measurement is relatively simple to implement in a clinical and home setting. Bronchial challenge testing is reserved for patients in whom the aforementioned testing has been unrevealing but clinical suspicion remains, though is associated with low specificity. Demonstration of eosinophilic inflammation, via fractional exhaled nitric oxide measurement, or atopy, may be supportive of atopic asthma, though diagnostic utility is limited particularly in nonatopic asthma. All efforts should be made to confirm the diagnosis of asthma in those who are being presumptively treated but have not had objective measurements of variability in the degree of obstruction. Multiple testing modalities are available for objective confirmation of airway obstruction and variability thereof, consistent with a diagnosis of asthma in the appropriate clinical context. Providers should be aware that both these characteristics may be present in other disease states, and may not be specific to a diagnosis of asthma. © 2015 ARS-AAOA, LLC.

  10. Estimation of Sensitivity and Specificity of Three Conditionally Dependent Diagnostic Tests in the Absence of a Gold Standard

    NARCIS (Netherlands)

    Engel, B.; Swildens, B.; Stegeman, J.A.; Buist, W.G.; Jong, de M.

    2006-01-01

    This article presents a model to evaluate the accuracy of diagnostic tests. Data from three tests for the detection of EF-positive Streptococcus suis serotype 2 strains in sows were analyzed. The data were collected in a field study in the absence of a gold standard, that is, the true disease status

  11. The Sensitivity, Specificity and Predictive Values of Snellen Chart Compared to the Diagnostic Test in Amblyopia Screening Program in Iran

    Directory of Open Access Journals (Sweden)

    Fatemeh Rivakani

    2015-12-01

    Full Text Available Introduction Amblyopia is a leading cause of visual impairment in both childhood and adult populations. Our aim in this study was to assess the epidemiological characteristics of the amblyopia screening program in Iran. Materials and Methods A cross-sectional study was done on a randomly selected sample of 4,636 Iranian children who were referred to screening program in 2013 were participated in validity study, too. From each provinces the major city were selected. Screening and diagnostic tests were done by instructors in first stage and optometrists in second stage, respectively. Finally data were analyzed by Stata version 13. Results The sensitivity was ranged from 74% to 100% among the various provinces such that Fars and Ardabil province had maximum and minimum values, respectively. The pattern of specificity was differ and ranged 44% to 84% among the provinces; Hormozgan and Fars had maximum and minimum values, respectively. The positive predictive value was also ranged from 35% to %81 which was assigned to Khuzestan and Ardabil provinces, respectively. The range of Negative Predictive value was 61% to 100% which was belonged to Ardabil and Fars provinces. Conclusion The total sensitivity (89% and negative predictive values (93% of screening test among children aged 3-6 years is acceptable, but only 51% of children refereed to second stage are true positive and this imposes considerable cost to health system.

  12. Rapid diagnostic tests as a source of DNA for Plasmodium species-specific real-time PCR

    Directory of Open Access Journals (Sweden)

    Van Esbroeck Marjan

    2011-03-01

    Full Text Available Abstract Background This study describes the use of malaria rapid diagnostic tests (RDTs as a source of DNA for Plasmodium species-specific real-time PCR. Methods First, the best method to recover DNA from RDTs was investigated and then the applicability of this DNA extraction method was assessed on 12 different RDT brands. Finally, two RDT brands (OptiMAL Rapid Malaria Test and SDFK60 malaria Ag Plasmodium falciparum/Pan test were comprehensively evaluated on a panel of clinical samples submitted for routine malaria diagnosis at ITM. DNA amplification was done with the 18S rRNA real-time PCR targeting the four Plasmodium species. Results of PCR on RDT were compared to those obtained by PCR on whole blood samples. Results Best results were obtained by isolating DNA from the proximal part of the nitrocellulose component of the RDT strip with a simple DNA elution method. The PCR on RDT showed a detection limit of 0.02 asexual parasites/μl, which was identical to the same PCR on whole blood. For all 12 RDT brands tested, DNA was detected except for one brand when a low parasite density sample was applied. In RDTs with a plastic seal covering the nitrocellulose strip, DNA extraction was hampered. PCR analysis on clinical RDT samples demonstrated correct identification for single species infections for all RDT samples with asexual parasites of P. falciparum (n = 60, Plasmodium vivax (n = 10, Plasmodium ovale (n = 10 and Plasmodium malariae (n = 10. Samples with only gametocytes were detected in all OptiMAL and in 10 of the 11 SDFK60 tests. None of the negative samples (n = 20 gave a signal by PCR on RDT. With PCR on RDT, higher Ct-values were observed than with PCR on whole blood, with a mean difference of 2.68 for OptiMAL and 3.53 for SDFK60. Mixed infections were correctly identified with PCR on RDT in 4/5 OptiMAL tests and 2/5 SDFK60 tests. Conclusions RDTs are a reliable source of DNA for Plasmodium real-time PCR. This study demonstrates the

  13. The interpretation of diagnostic tests

    International Nuclear Information System (INIS)

    Lamk, M.; Lamki, M.D.

    1987-01-01

    The progress of nuclear and other diagnostic imaging is near rampant. With almost every issue of the major journals in this field, a new diagnostic test, or at least a new utility of an old test is described. Before we accept these innovations, we have to have a clear understanding of the clinical performance of the test. The major criteria are the sensitivity and the specificity of the test. From these derived other statistical parameters such as accuracy or efficiency of that test; also, the receiver operating characteristic (ROC) curves may then be evaluated and used in comparison of different tests. When we know the prevalence of the disease tested in the population we are investigating, we can then derive the predictive value of a positive or a negative result. This introduction tries to explain these parameters to help the reader understand the literature dealing with the subject of efficacy of imaging procedures. It is not intended as a critical review of the literature on the subject or a comprehensive overview of the subject matter. The benefit derived from explaination of statistical concepts to physicians is documented in a recent publication. Explaination of these basic statistical parameters will be followed by a demonstration of the utility of multiple testing with these parameters. The reader is thereby introduced to relevant statistical concepts that must be grasped for full comprehension of published results of a new diagnostic imaging modality, or before clinical decision making

  14. Pearls and pitfalls of allergy diagnostic testing: report from the American College of Allergy, Asthma and Immunology/American Academy of Allergy, Asthma and Immunology Specific IgE Test Task Force.

    Science.gov (United States)

    Cox, Linda; Williams, Brock; Sicherer, Scott; Oppenheimer, John; Sher, Larry; Hamilton, Robert; Golden, David

    2008-12-01

    The intended purpose of this monograph is to provide a general overview of allergy diagnostics for health care professionals who care for patients with allergic disease. For a more comprehensive review of allergy diagnostic testing, readers can refer to the Allergy Diagnostic Practice Parameters. A key message is that a positive allergy test result (skin or blood) indicates only the presence of allergen specific IgE (called sensitization). It does not necessarily mean clinical allergy (ie, allergic symptoms with exposure). It is important for this reason that the allergy evaluation be based on the patient's history and directed by a health care professional with sufficient understanding of allergy diagnostic testing to use the information obtained from his/her evaluation of the patient to determine (1) what allergy diagnostic tests to order, (2) how to interpret the allergy diagnostic test results, and (3) how to use the information obtained from the allergy evaluation to develop an appropriate therapeutic treatment plan.

  15. Empirical likelihood-based confidence intervals for the sensitivity of a continuous-scale diagnostic test at a fixed level of specificity.

    Science.gov (United States)

    Gengsheng Qin; Davis, Angela E; Jing, Bing-Yi

    2011-06-01

    For a continuous-scale diagnostic test, it is often of interest to find the range of the sensitivity of the test at the cut-off that yields a desired specificity. In this article, we first define a profile empirical likelihood ratio for the sensitivity of a continuous-scale diagnostic test and show that its limiting distribution is a scaled chi-square distribution. We then propose two new empirical likelihood-based confidence intervals for the sensitivity of the test at a fixed level of specificity by using the scaled chi-square distribution. Simulation studies are conducted to compare the finite sample performance of the newly proposed intervals with the existing intervals for the sensitivity in terms of coverage probability. A real example is used to illustrate the application of the recommended methods.

  16. Sensitivity, Specificity, Predictive Values, and Accuracy of Three Diagnostic Tests to Predict Inferior Alveolar Nerve Blockade Failure in Symptomatic Irreversible Pulpitis

    Directory of Open Access Journals (Sweden)

    Daniel Chavarría-Bolaños

    2017-01-01

    Full Text Available Introduction. The inferior alveolar nerve block (IANB is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP. Methodology. A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results. IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.. A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p<0.05. Conclusion. None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure.

  17. Comparing diagnostic tests on benefit-risk.

    Science.gov (United States)

    Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott

    2016-01-01

    Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.

  18. What Is Diagnostic Testing?

    Science.gov (United States)

    ... your family Plan for the future Insurance and financial planning Transition for children Emergency preparedness Testing & Services Testing ... Support Genetic Disease Information Find a Support Group Financial Planning Who Should I Tell? Genetic Testing & Counseling Compensation ...

  19. Methodology of diagnostic tests in hepatology

    DEFF Research Database (Denmark)

    Christensen, Erik

    2009-01-01

    The performance of diagnostic tests can be assessed by a number of methods. These include sensitivity, specificity,positive and negative predictive values, likelihood ratios and receiver operating characteristic (ROC) curves. This paper describes the methods and explains which information...... they provide. Sensitivity and specificity provides measures of the diagnostic accuracy of a test in diagnosing the condition. The positive and negative predictive values estimate the probability of the condition from the test-outcome and the condition's prevalence. The likelihood ratios bring together......' and plotting sensitivity as a function of 1-specificity. The ROC-curve can be used to define optimal cut-off values for a test, to assess the diagnostic accuracy of the test, and to compare the usefulness of different tests in the same patients. Under certain conditions it may be possible to utilize a test...

  20. Modelling the Impact and Cost-Effectiveness of Biomarker Tests as Compared with Pathogen-Specific Diagnostics in the Management of Undifferentiated Fever in Remote Tropical Settings.

    Directory of Open Access Journals (Sweden)

    Yoel Lubell

    Full Text Available Malaria accounts for a small fraction of febrile cases in increasingly large areas of the malaria endemic world. Point-of-care tests to improve the management of non-malarial fevers appropriate for primary care are few, consisting of either diagnostic tests for specific pathogens or testing for biomarkers of host response that indicate whether antibiotics might be required. The impact and cost-effectiveness of these approaches are relatively unexplored and methods to do so are not well-developed.We model the ability of dengue and scrub typhus rapid tests to inform antibiotic treatment, as compared with testing for elevated C-Reactive Protein (CRP, a biomarker of host-inflammation. Using data on causes of fever in rural Laos, we estimate the proportion of outpatients that would be correctly classified as requiring an antibiotic and the likely cost-effectiveness of the approaches.Use of either pathogen-specific test slightly increased the proportion of patients correctly classified as requiring antibiotics. CRP testing was consistently superior to the pathogen-specific tests, despite heterogeneity in causes of fever. All testing strategies are likely to result in higher average costs, but only the scrub typhus and CRP tests are likely to be cost-effective when considering direct health benefits, with median cost per disability adjusted life year averted of approximately $48 USD and $94 USD, respectively.Testing for viral infections is unlikely to be cost-effective when considering only direct health benefits to patients. Testing for prevalent bacterial pathogens can be cost-effective, having the benefit of informing not only whether treatment is required, but also as to the most appropriate antibiotic; this advantage, however, varies widely in response to heterogeneity in causes of fever. Testing for biomarkers of host inflammation is likely to be consistently cost-effective despite high heterogeneity, and can also offer substantial reductions in

  1. Modelling the Impact and Cost-Effectiveness of Biomarker Tests as Compared with Pathogen-Specific Diagnostics in the Management of Undifferentiated Fever in Remote Tropical Settings.

    Science.gov (United States)

    Lubell, Yoel; Althaus, Thomas; Blacksell, Stuart D; Paris, Daniel H; Mayxay, Mayfong; Pan-Ngum, Wirichada; White, Lisa J; Day, Nicholas P J; Newton, Paul N

    2016-01-01

    Malaria accounts for a small fraction of febrile cases in increasingly large areas of the malaria endemic world. Point-of-care tests to improve the management of non-malarial fevers appropriate for primary care are few, consisting of either diagnostic tests for specific pathogens or testing for biomarkers of host response that indicate whether antibiotics might be required. The impact and cost-effectiveness of these approaches are relatively unexplored and methods to do so are not well-developed. We model the ability of dengue and scrub typhus rapid tests to inform antibiotic treatment, as compared with testing for elevated C-Reactive Protein (CRP), a biomarker of host-inflammation. Using data on causes of fever in rural Laos, we estimate the proportion of outpatients that would be correctly classified as requiring an antibiotic and the likely cost-effectiveness of the approaches. Use of either pathogen-specific test slightly increased the proportion of patients correctly classified as requiring antibiotics. CRP testing was consistently superior to the pathogen-specific tests, despite heterogeneity in causes of fever. All testing strategies are likely to result in higher average costs, but only the scrub typhus and CRP tests are likely to be cost-effective when considering direct health benefits, with median cost per disability adjusted life year averted of approximately $48 USD and $94 USD, respectively. Testing for viral infections is unlikely to be cost-effective when considering only direct health benefits to patients. Testing for prevalent bacterial pathogens can be cost-effective, having the benefit of informing not only whether treatment is required, but also as to the most appropriate antibiotic; this advantage, however, varies widely in response to heterogeneity in causes of fever. Testing for biomarkers of host inflammation is likely to be consistently cost-effective despite high heterogeneity, and can also offer substantial reductions in over-use of

  2. Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; Reitsma, Johannes B.; Linnet, Kristian; Moons, Karel G. M.

    2012-01-01

    Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical

  3. [The comparative study of specificity of test-systems in diagnostic of HIV-infection on categories of samples of blood serum of pregnant women].

    Science.gov (United States)

    Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I

    2015-03-01

    The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.

  4. Urine specific gravity test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003587.htm Urine specific gravity test To use the sharing features on this page, please enable JavaScript. Urine specific gravity is a laboratory test that shows the concentration ...

  5. Local Sensitivity and Diagnostic Tests

    NARCIS (Netherlands)

    Magnus, J.R.; Vasnev, A.L.

    2004-01-01

    In this paper we confront sensitivity analysis with diagnostic testing.Every model is misspecified, but a model is useful if the parameters of interest (the focus) are not sensitive to small perturbations in the underlying assumptions. The study of the e ect of these violations on the focus is

  6. Understanding the properties of diagnostic tests - Part 2: Likelihood ratios.

    Science.gov (United States)

    Ranganathan, Priya; Aggarwal, Rakesh

    2018-01-01

    Diagnostic tests are used to identify subjects with and without disease. In a previous article in this series, we examined some attributes of diagnostic tests - sensitivity, specificity, and predictive values. In this second article, we look at likelihood ratios, which are useful for the interpretation of diagnostic test results in everyday clinical practice.

  7. Sensitivity and Specificity of a Prototype Rapid Diagnostic Test for the Detection of Trypanosoma brucei gambiense Infection: A Multi-centric Prospective Study.

    Science.gov (United States)

    Bisser, Sylvie; Lumbala, Crispin; Nguertoum, Etienne; Kande, Victor; Flevaud, Laurence; Vatunga, Gedeao; Boelaert, Marleen; Büscher, Philippe; Josenando, Theophile; Bessell, Paul R; Biéler, Sylvain; Ndung'u, Joseph M

    2016-04-01

    A major challenge in the control of human African trypanosomiasis (HAT) is lack of reliable diagnostic tests that are rapid and easy to use in remote areas where the disease occurs. In Trypanosoma brucei gambiense HAT, the Card Agglutination Test for Trypanosomiasis (CATT) has been the reference screening test since 1978, usually on whole blood, but also in a 1/8 dilution (CATT 1/8) to enhance specificity. However, the CATT is not available in a single format, requires a cold chain for storage, and uses equipment that requires electricity. A solution to these challenges has been provided by rapid diagnostic tests (RDT), which have recently become available. A prototype immunochromatographic test, the SD BIOLINE HAT, based on two native trypanosomal antigens (VSG LiTat 1.3 and VSG LiTat 1.5) has been developed. We carried out a non-inferiority study comparing this prototype to the CATT 1/8 in field settings. The prototype SD BIOLINE HAT, the CATT Whole Blood and CATT 1/8 were systematically applied on fresh blood samples obtained from 14,818 subjects, who were prospectively enrolled through active and passive screening in clinical studies in three endemic countries of central Africa: Angola, the Democratic Republic of the Congo and the Central African Republic. One hundred and forty nine HAT cases were confirmed by parasitology. The sensitivity and specificity of the prototype SD BIOLINE HAT was 89.26% (95% confidence interval (CI) = 83.27-93.28) and 94.58% (95% CI = 94.20-94.94) respectively. The sensitivity and specificity of the CATT on whole blood were 93.96% (95% CI = 88.92-96.79) and 95.91% (95% CI = 95.58-96.22), and of the CATT 1/8 were 89.26% (95% CI = 83.27-93.28) and 98.88% (95% CI = 98.70-99.04) respectively. After further optimization, the prototype SD BIOLINE HAT could become an alternative to current screening methods in primary healthcare settings in remote, resource-limited regions where HAT typically occurs.

  8. Comparative Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

     This document includes a definition of the comparative test cases DSF200_3 and DSF200_4, which previously described in the comparative test case specification for the test cases DSF100_3 and DSF200_3 [Ref.1]....... This document includes a definition of the comparative test cases DSF200_3 and DSF200_4, which previously described in the comparative test case specification for the test cases DSF100_3 and DSF200_3 [Ref.1]....

  9. Molecular Diagnostic Tests for Microsporidia

    Directory of Open Access Journals (Sweden)

    Kaya Ghosh

    2009-01-01

    Full Text Available The Microsporidia are a ubiquitous group of eukaryotic obligate intracellular parasites which were recognized over 100 years ago with the description of Nosema bombycis, a parasite of silkworms. It is now appreciated that these organisms are related to the Fungi. Microsporidia infect all major animal groups most often as gastrointestinal pathogens; however they have been reported from every tissue and organ, and their spores are common in environmental sources such as ditch water. Several different genera of these organisms infect humans, but the majority of infections are due to either Enterocytozoon bieneusi or Encephalitozoon species. These pathogens can be difficult to diagnose, but significant progress has been made in the last decade in the development of molecular diagnostic reagents for these organisms. This report reviews the molecular diagnostic tests that have been described for the identification of the microsporidia that infect humans.

  10. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  11. Comparative Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

    This document includes the specification on the IEA task of evaluation building energy simulation computer programs for the Double Skin Facades (DSF) constructions. There are two approaches involved into this procedure, one is the comparative approach and another is the empirical one. In the comp....... In the comparative approach the outcomes of different software tools are compared, while in the empirical approach the modelling results are compared with the results of experimental test cases. The comparative test cases include: ventilation, shading and geometry....

  12. Empirical Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

    This document includes the empirical specification on the IEA task of evaluation building energy simulation computer programs for the Double Skin Facades (DSF) constructions. There are two approaches involved into this procedure, one is the comparative approach and another is the empirical one. I....... In the comparative approach the outcomes of different software tools are compared, while in the empirical approach the modelling results are compared with the results of experimental test cases....

  13. Immunochromatographic diagnostic test analysis using Google Glass.

    Science.gov (United States)

    Feng, Steve; Caire, Romain; Cortazar, Bingen; Turan, Mehmet; Wong, Andrew; Ozcan, Aydogan

    2014-03-25

    We demonstrate a Google Glass-based rapid diagnostic test (RDT) reader platform capable of qualitative and quantitative measurements of various lateral flow immunochromatographic assays and similar biomedical diagnostics tests. Using a custom-written Glass application and without any external hardware attachments, one or more RDTs labeled with Quick Response (QR) code identifiers are simultaneously imaged using the built-in camera of the Google Glass that is based on a hands-free and voice-controlled interface and digitally transmitted to a server for digital processing. The acquired JPEG images are automatically processed to locate all the RDTs and, for each RDT, to produce a quantitative diagnostic result, which is returned to the Google Glass (i.e., the user) and also stored on a central server along with the RDT image, QR code, and other related information (e.g., demographic data). The same server also provides a dynamic spatiotemporal map and real-time statistics for uploaded RDT results accessible through Internet browsers. We tested this Google Glass-based diagnostic platform using qualitative (i.e., yes/no) human immunodeficiency virus (HIV) and quantitative prostate-specific antigen (PSA) tests. For the quantitative RDTs, we measured activated tests at various concentrations ranging from 0 to 200 ng/mL for free and total PSA. This wearable RDT reader platform running on Google Glass combines a hands-free sensing and image capture interface with powerful servers running our custom image processing codes, and it can be quite useful for real-time spatiotemporal tracking of various diseases and personal medical conditions, providing a valuable tool for epidemiology and mobile health.

  14. [Diagnostic test scale SI5: Assessment of sacroiliac joint dysfunction].

    Science.gov (United States)

    Acevedo González, Juan C; Quintero Oliveros, Silvia

    2015-01-01

    Sacroiliac joint dysfunction is a known cause of low back pain. We think that a diagnostic score scale (SI5) may be performed to assess diagnostic utility of clinical signs of sacroiliac joint dysfunction. The primary aim of the present study was to conduct the pilot study of our new diagnostic score scale, the SI5, for sacroiliac joint syndrome. We reviewed the literature on clinical characteristics, diagnostic tests and imaging most commonly used in diagnosing sacroiliac joint dysfunction. Our group evaluated the diagnostic utility of these aspects and we used those considered most representative to develop the SI5 diagnostic scale. The SI5 scale was applied to 22 patients with low back pain; afterwards, the standard test for diagnosing this pathology (selective blockage of the SI joint) was also performed on these patients. The sensitivity and specificity for each sign were also assessed and the diagnostic scale called SI5 was then proposed, based on these data. The most sensitive clinical tests for diagnosing SI joint dysfunction were 2 patient-reported clinical characteristics, the Laguerre Test, sacroiliac rocking test and Yeomans test (greater than 80% sensitivity). The tests with greatest diagnostic specificity (>80%) were the Lewitt test, Piedallu test and Gillet test. The proposed SI5 test score scale showed sensitivity of 73% and specificity of 71%. Sacroiliac joint syndrome has been shown to produce low back pain frequently; however, the diagnostic value of examination tests for sacroiliac joint pain has been questioned by other authors. The pilot study on the SI5 diagnostic score scale showed good sensitivity and specificity. However, the process of statistical validation of the SI5 needs to be continued. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  15. Diagnostic Tests in Human Brucellosis

    Directory of Open Access Journals (Sweden)

    Hamid Reza Nouri

    2014-07-01

    Full Text Available Context: Brucellosis represents a zoonotic bacterial disease, caused by a gram negative bacterium called Brucella. Between the diverses pecies of this bacteria, B. melitensis, B. abortus, B. suis and B. canis consist the main causes of the disease in humans.More than half a million new cases of Brucellosis are reported annually. Consequently, brucellosis is a remarkable threat for the health of society. Because of the multiple nonspecific clinical signs of this infection, such as fever (60% of cases, night sweating, insomnia and anorexia, which are similar to other diseases, the detection of brucellosis is time-consuming and needs more scrutiny. Evidence Acquisition: Blood culture is considered the gold standard for the detection of brucellosis and the sensitivity of this test in the acute form is high. However, for the chronic type of disease, it is remarkably low, in addition, in some cases, it needs long reaction times. Nevertheless, today, some kinds of tests like automatic culturing system and serological methods, such as Rose Bengal (RB test, serum agglutination test (SAT, 2-mercaptoethanol (2ME and coombs, which are operated based on agglutination, are useful for the problems mentioned earlier. Conclusion: Although serological methods are common for the diagnosis of brucellosis, false results are observable for several methods, such as the SAT method. Tests like the enzyme-linked immunosorbent assay (ELISA, for the screening of specific traits, although confirmed, have their advantages and defects. The lateral flow assay (LFA shows promising evidence to be effective in the diagnosis of brucellosis. The polymerase chain reaction (PCR is more prevalent than other common tests, according to sensitivity and fast answering potency in case of molecular diagnosis. Also, PCR is proper for patients' follow-up during the period of treatment and crimination of relapse by this method is easier compared to others.

  16. How to appraise a diagnostic test

    Directory of Open Access Journals (Sweden)

    Ramanitharan Manikandan

    2011-01-01

    Full Text Available Urologists frequently encounter problems in making a clinical diagnosis whose resolution requires the use of diagnostic tests. With an ever increasing choice of investigations being available, the urologist often has to decide which diagnostic test(s will best resolve the patient′s diagnostic problem. In this article, we aim to help the urologist understand how to critically appraise studies on diagnostic tests and make a rational choice. This article presents the guiding principles in scientifically assessing studies on diagnostic tests by proposing a clinical scenario. The authors describe a standardized protocol to assess the validity of the test and its relevance to the clinical problem that can help the urologist in decision making. The three important issues to be considered when evaluating the validity of the study are to identify how the study population was chosen, how the test was performed and whether there is a comparison to the gold standard test so as to confirm or refute the diagnosis. Then, the urologist would need to know the probability of the test in providing the correct diagnosis in an individual patient in order to decide about its utility in solving the diagnostic dilemma. By performing the steps described in this article, the urologist would be able to critically appraise diagnostic studies and draw meaningful conclusions about the investigations in terms of validity, results and its applicability to the patient′s problem. This would provide a scientific basis for using diagnostic tests for improving patient care.

  17. The diagnostic odds ratio: a single indicator of test performance

    NARCIS (Netherlands)

    Glas, Afina S.; Lijmer, Jeroen G.; Prins, Martin H.; Bonsel, Gouke J.; Bossuyt, Patrick M. M.

    2003-01-01

    Diagnostic testing can be used to discriminate subjects with a target disorder from subjects without it. Several indicators of diagnostic performance have been proposed, such as sensitivity and specificity. Using paired indicators can be a disadvantage in comparing the performance of competing

  18. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  19. Optimizing diagnostic tests for persulphate

    DEFF Research Database (Denmark)

    Foss-Skiftesvik, Majken H; Winther, Lotte; Mosbech, Holger Fausbøll

    2016-01-01

    for both rhinitis and asthma simultaneously in 1 day. In addition, we assessed the suitability of SPTs and HRTs for detecting persulphate-induced respiratory diseases. METHODS: The study population included 19 hairdressers with a history of work-related rhinitis and/or asthma symptoms, 12 symptomatic...... showed nonspecific non-IgE mediated histamine release to persulphates in HRT. CONCLUSIONS: The proposed method for performing SIC showed a high specificity for detecting persulphate-induced asthma and rhinitis. The rapid SIC was able to produce positive nasal and bronchial responses in symptomatic...

  20. Variation of a test's sensitivity and specificity with disease prevalence

    NARCIS (Netherlands)

    Leeflang, Mariska M. G.; Rutjes, Anne W. S.; Reitsma, Johannes B.; Hooft, Lotty; Bossuyt, Patrick M. M.

    2013-01-01

    Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. We used data from 23

  1. Diagnostic tests based on human basophils

    DEFF Research Database (Denmark)

    Kleine-Tebbe, Jörg; Erdmann, Stephan; Knol, Edward F

    2006-01-01

    -maximal responses, termed 'intrinsic sensitivity'. These variables give rise to shifts in the dose-response curves which, in a diagnostic setting where only a single antigen concentration is employed, may produce false-negative data. Thus, in order to meaningfully utilize the current basophil activation tests....... Diagnostic studies using CD63 or CD203c in hymenoptera, food and drug allergy are critically discussed. Basophil-based tests are indicated for allergy testing in selected cases but should only be performed by experienced laboratories....

  2. Tumor specific lung cancer diagnostics with multiplexed FRET immunoassays

    Science.gov (United States)

    Geißler, D.; Hill, D.; Löhmannsröben, H.-G.; Thomas, E.; Lavigne, A.; Darbouret, B.; Bois, E.; Charbonnière, L. J.; Ziessel, R. F.; Hildebrandt, N.

    2010-02-01

    An optical multiplexed homogeneous (liquid phase) immunoassay based on FRET from a terbium complex to eight different fluorescent dyes is presented. We achieved highly sensitive parallel detection of four different lung cancer specific tumor markers (CEA, NSE, SCC and CYFRA21-1) within a single assay and show a proof-of-principle for 5- fold multiplexing. The method is well suited for fast and low-cost miniaturized point-of-care testing as well as for highthroughput screening in a broad range of in-vitro diagnostic applications.

  3. Systematic reviews of diagnostic test accuracy

    DEFF Research Database (Denmark)

    Leeflang, Mariska M G; Deeks, Jonathan J; Gatsonis, Constantine

    2008-01-01

    More and more systematic reviews of diagnostic test accuracy studies are being published, but they can be methodologically challenging. In this paper, the authors present some of the recent developments in the methodology for conducting systematic reviews of diagnostic test accuracy studies....... Restrictive electronic search filters are discouraged, as is the use of summary quality scores. Methods for meta-analysis should take into account the paired nature of the estimates and their dependence on threshold. Authors of these reviews are advised to use the hierarchical summary receiver...

  4. Analysis of the Astronomy Diagnostic Test

    Science.gov (United States)

    Brogt, Erik; Sabers, Darrell; Prather, Edward E.; Deming, Grace L.; Hufnagel, Beth; Slater, Timothy F.

    2007-01-01

    Seventy undergraduate class sections were examined from the database of Astronomy Diagnostic Test (ADT) results of Deming and Hufnagel to determine if course format correlated with ADT normalized gain scores. Normalized gains were calculated for four different classroom scenarios: lecture, lecture with discussion, lecture with lab, and lecture…

  5. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    Science.gov (United States)

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Results of Drug addiction Test and its Correlation With the Demographic Specifications Among People Referred to Yazd Addiction Diagnostic Laboratory Centre

    Directory of Open Access Journals (Sweden)

    2014-05-01

    Full Text Available Abstract Introduction: Addiction changes people from positive, active and healthy beings to consuming and negative patients. This study was carried out with the aim of determining the prevalence of the abuse of epioid substances among people referring to Yazd Addiction Diagnosis Laboratory using Rapid Test and Chromatography. Methods: In this descriptive cross-sectional study, all people who attended Yazd Addiction Diagnosis Laboratory for any reason, that is, marriage, employment or obtaining job license between 1386 and 1388, were examined. Totally, 2790 individuals were selected randomly. First, their demographic information was entered in the questionnaire. Then, urine samples were collected at the presence of a laboratory technician and tested using Ennissan Strip Rapid Test if the result was positive, the rest of the sample was tested with Chromatography. Results: Totally, 2790 individuals were surveyed in this study. The mean age of the participants was 25.9±7.2 years. About 62.9% were male and the rest were female. In addition, the reason for taking the test was marriage in 73.2%, employment in 15.5%, obtaining job license in 3.3% and other reasons for others. The prevalence of the abuse of opioid substances was 5.3% (95% CI 4.5% - 6.1%. Conclusions: Many test takers are aware of the fact that the result of the drug test becomes negative after three days of withdrawal, which might be the reason for the low prevalence of addiction in this study. However, prenuptial testing for addiction is quite prudent and necessary. Moreover, calculation of OR showed a male to female ratio of 15 to 1 for opioid abuse which was significant. Higher age, lower education level, labor work and working freelance, smoking and history of addiction in family were other risk factors for opioid substance abuse. Keywords: Addiction test, Addiction prevalence rate, Rapid test, Yazd

  7. Antiphospholipid Syndrome Laboratory Testing and Diagnostic Strategies

    Science.gov (United States)

    Ortel, Thomas L.

    2016-01-01

    The Antiphospholipid Syndrome (APS) is diagnosed in patients with recurrent thromboembolic events and/or pregnancy loss in the presence of persistent laboratory evidence for antiphospholipid antibodies. Diagnostic tests for the detection of antiphospholipid antibodies include laboratory assays that detect anticardiolipin antibodies, lupus anticoagulants, and anti-β2-glycoprotein I antibodies. These assays have their origins beginning more than sixty years ago, with the identification of the biologic false positive test for syphilis, the observation of ‘circulating anticoagulants’ in certain patients with systemic lupus erythematosus, the identification of cardiolipin as a key component in the serologic test for syphilis, and the recognition and characterization of a ‘cofactor’ for antibody binding to phospholipids. Although these assays have been used clinically for many years, there are still problems with the accurate diagnosis of patients with this syndrome. For example, lupus anticoagulant testing can be difficult to interpret in patients receiving anticoagulant therapy, but most patients with a thromboembolic event will already be anticoagulated before the decision to perform the tests has been made. In addition to understanding limitations of the assays, clinicians also need to be aware of which patients should be tested and not obtain testing on patients unlikely to have APS. New tests and diagnostic strategies are in various stages of development and should help improve our ability to accurately diagnose this important clinical disorder. PMID:22473619

  8. The evaluation and impact of diagnostic tests

    International Nuclear Information System (INIS)

    Royal, H.D.; McNeil, B.J.

    1989-01-01

    The authors describe the usefulness of the techniques that are applied to study the role of tests and point out their limitations. In many instances, complex tasks must be oversimplified in order to use currently available analytic tools. Certain tools, such as decision analysis, are useful not only because they can provide insight regarding the most favorable diagnostic/therapeutic strategies but also because they can identify areas where present knowledge is inadequate and thereby help put priorities on areas of research

  9. Molecular diagnostic testing for primary biliary cholangitis.

    Science.gov (United States)

    Gatselis, Nikolaos K; Dalekos, George N

    2016-09-01

    A reliable liver autoimmune serology for the diagnosis of primary biliary cholangitis (PBC) is of particular importance. Recognition of patients at early stages and prompt treatment initiation may alter the outcome, slow progression, delays liver failure, and improves survival. In this review, we summarize and discuss the published data obtained from literature searches from PubMed and The National Library of Medicine (USA) and our own experience on the current and potential molecular based approaches to the diagnosis of PBC. Expert commentary: Standardization of liver diagnostic serology and clinical governance are two major points as antimitochondrial antibodies are the diagnostic hallmark of the disease and PBC-specific antinuclear antibodies could assist in the diagnosis and estimation of prognosis. New biomarkers such as novel autoantibodies, genetic polymorphisms, metabolomic profiling, micro-RNA and epigenetics may assist to the understanding, diagnosis and management of the disease.

  10. The Evaluation of Diagnostic Tests for Sexually Transmitted Infections

    Directory of Open Access Journals (Sweden)

    Max A Chernesky

    2005-01-01

    Full Text Available Diagnostic tests should receive method- and use-effectiveness evaluations. Method-effectiveness evaluations determine sensitivity, specificity and predictive values for new tests. Use-effectiveness evaluations determine how practical or convenient a new test will be in a specific setting and may not be performed in a formal way in North American laboratories. To perform a clinical method evaluation of diagnostic tests, a good relationship between laboratory and clinical personnel is essential. Studies are usually conducted separately on populations of men and women, and should include sampling from different prevalence groups. Test performance comparisons may be made on a single specimen type or on more than one specimen from the same patient, which allows for the expansion of a reference standard and includes the ability of a particular assay, performed on a specimen type to diagnose an infected individual. The following components of the evaluation should be standardized and carefully followed: specimen identification; collection; transportation; processing; quality control; reading; proficiency testing; confirmatory testing; discordant analysis -- sensitivity, specificity and predictive value calculations; and record keeping. Methods are available to determine whether sample results are true or false positives or negatives. Use-effectiveness evaluations might determine the stability or durability of supplies and equipment; the logistics of shipping, receiving and storing supplies; the clarity and completeness of test instructions; the time and effort required to process and read results; the subjectivity factors in interpretation and reporting; and the costs. These determinations are usually more apparent for commercial assays than for homemade tests.

  11. Divergence-based tests for model diagnostic

    Czech Academy of Sciences Publication Activity Database

    Hobza, Tomáš; Esteban, M. D.; Morales, D.; Marhuenda, Y.

    2008-01-01

    Roč. 78, č. 13 (2008), s. 1702-1710 ISSN 0167-7152 R&D Projects: GA MŠk 1M0572 Grant - others:Instituto Nacional de Estadistica (ES) MTM2006-05693 Institutional research plan: CEZ:AV0Z10750506 Keywords : goodness of fit * devergence statistics * GLM * model checking * bootstrap Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.445, year: 2008 http://library.utia.cas.cz/separaty/2008/SI/hobza-divergence-based%20tests%20for%20model%20diagnostic.pdf

  12. Beam Diagnostics for the BNL Energy Recovery Linac Test Facility

    International Nuclear Information System (INIS)

    Cameron, Peter; Ben-Zvi, Ilan; Blaskiewicz, Michael; Brennan, Michael; Connolly, Roger; Dawson, William; Degen, Chris; DellaPenna, Al; Gassner, David; Kesselman, Martin; Kewish, Jorg; Litvinenko, Vladimir; Mead, Joseph; Oerter, Brian; Russo, Tom; Vetter, Kurt; Yakimenko, Vitaly

    2004-01-01

    An Energy Recovery Linac (ERL) test facility is presently under construction at BNL. The goals of this test facility are first to demonstrate stable intense CW electron beam with parameters typical for the RHIC e-cooling project (and potentially for eRHIC), second to test novel elements of the ERL (high current CW photo-cathode, superconducting RF cavity with HOM dampers, and feedback systems), and finally to test lattice dependence of stability criteria. Planned diagnostics include position monitors, loss monitors, transverse profile monitors (both optical and wires), scrapers/halo monitors, a high resolution differential current monitor, phase monitors, an energy spread monitor, and a fast transverse monitor (for beam break-up studies and the energy feedback system). We discuss diagnostics challenges that are unique to this project, and present preliminary system specifications. In addition, we include a brief discussion of the timing system

  13. SPECIFICITY OF MANIFACTURING PROCESS VALIDATION FOR DIAGNOSTIC SEROLOGICAL DEVICES

    Directory of Open Access Journals (Sweden)

    O. Yu. Galkin

    2018-02-01

    Full Text Available The aim of this research was to analyze recent scientific literature, as well as national and international legislature on manifacturing process validation of biopharmaceutical production, in particular devices for serological diagnostics. Technology validation in the field of medical devices for serological diagnostics is most influenced by the Technical Regulation for Medical Devices for in vitro Diagnostics State Standards of Ukraine – SSU EN ISO 13485:2015 “Medical devices. Quality management system. Requirements for regulation”, SSU EN ISO 14971:2015 “Medical devices. Instructions for risk management”, Instruction ST-N of the Ministry of Healthcare of Ukraine 42-4.0:2014 “Medications. Suitable industrial practice”, State Pharmacopoeia of Ukraine and Instruction ICH Q9 on risk management. Current recommendations for validations of drugs manufacturing process, including biotechnological manufacturing, can not be directly applied to medical devices for in vitro diagnostics. It was shown that the specifics of application and raw materials require individual validation parameters and process validations for serological diagnostics devices. Critical parameters to consider in validation plans were provided for every typical stage of production of in vitro diagnostics devices on the example of immunoassay kits, such as obtaining protein antigens, including recombinant ones, preparations of mono- and polyclonal antibodies, immunoenzyme conjugates and immunosorbents, chemical reagents etc. The bottlenecks of technologies for in vitro diagnostics devices were analyzed from the bioethical and biosafety points of view.

  14. Testing of badminton specific endurance

    DEFF Research Database (Denmark)

    Madsen, Christian Møller; Højlyng, Mads; Nybo, Lars

    2016-01-01

    In the present study, a novel intermittent badminton endurance test (B-ENDURANCE) was developed and tested in elite (n=17) and skilled (n=9) badminton players as well as in age-matched physically active men (non-badminton players; n=8). In addition, B-ENDURANCE test-retest reproducibility...... was evaluated in nine badminton players.B-ENDURANCE is an incremental test where each level consists of repeated sequences of badminton specific actions towards the four corners on the court. The subject starts in the center of the court in front of a computer screen and within each sequence he must...... decreases until the subjects cannot follow the dictated tempo.B-ENDURANCE performance for elite players was better (Pbadminton players. In addition, B-ENDURANCE performance correlated (r=0.8; P

  15. Laboratory development and testing of spacecraft diagnostics

    Science.gov (United States)

    Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric

    2017-10-01

    The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.

  16. Mirror fusion test facility plasma diagnostics system

    International Nuclear Information System (INIS)

    Thomas, S.R. Jr.; Coffield, F.E.; Davis, G.E.; Felker, B.

    1979-01-01

    During the past 25 years, experiments with several magnetic mirror machines were performed as part of the Magnetic Fusion Energy (MFE) Program at LLL. The latest MFE experiment, the Mirror Fusion Test Facility (MFTF), builds on the advances of earlier machines in initiating, stabilizing, heating, and sustaining plasmas formed with deuterium. The goals of this machine are to increase ion and electron temperatures and show a corresponding increase in containment time, to test theoretical scaling laws of plasma instabilities with increased physical dimensions, and to sustain high-beta plasmas for times that are long compared to the energy containment time. This paper describes the diagnostic system being developed to characterize these plasma parameters

  17. Technology diffusion and diagnostic testing for prostate cancer.

    Science.gov (United States)

    Schroeck, Florian R; Kaufman, Samuel R; Jacobs, Bruce L; Skolarus, Ted A; Miller, David C; Weizer, Alon Z; Montgomery, Jeffrey S; Wei, John T; Shahinian, Vahakn B; Hollenbeck, Brent K

    2013-11-01

    While the dissemination of robotic prostatectomy and intensity modulated radiotherapy may fuel the increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with the receipt of prostate specific antigen testing and prostate biopsy. In this retrospective cohort study we included 117,857 men 66 years old or older from the 5% sample of Medicare beneficiaries living in Surveillance, Epidemiology and End Results (SEER) areas from 2003 to 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or intensity modulated radiotherapy per population in a health care market, ie hospital referral region. We assessed the association of technology penetration with the prostate specific antigen testing rate and prostate biopsy using generalized estimating equations. High technology penetration was associated with an increased rate of prostate specific antigen testing (442 vs 425/1,000 person-years, pimpact of technology penetration on prostate specific antigen testing and prostate biopsy was much less than the effect of age, race and comorbidity, eg the prostate specific antigen testing rate per 1,000 person-years was 485 vs 373 for men with only 1 vs 3+ comorbid conditions (ppenetration is associated with a slightly higher rate of prostate specific antigen testing and no change in the prostate biopsy rate. Collectively, our findings temper concerns that adopting new technology accelerates diagnostic testing for prostate cancer. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Privacy and equality in diagnostic genetic testing.

    Science.gov (United States)

    Nyrhinen, Tarja; Hietala, Marja; Puukka, Pauli; Leino-Kilpi, Helena

    2007-05-01

    This study aimed to determine the extent to which the principles of privacy and equality were observed during diagnostic genetic testing according to views held by patients or child patients' parents (n = 106) and by staff (n = 162) from three Finnish university hospitals. The data were collected through a structured questionnaire and analysed using the SAS 8.1 statistical software. In general, the two principles were observed relatively satisfactorily in clinical practice. According to patients/parents, equality in the post-analytic phase and, according to staff, privacy in the pre-analytic phase, involved the greatest ethical problems. The two groups differed in their views concerning pre-analytic privacy. Although there were no major problems regarding the two principles, the differences between the testing phases require further clarification. To enhance privacy protection and equality, professionals need to be given more genetics/ethics training, and patients individual counselling by genetics units staff, giving more consideration to patients' world-view, the purpose of the test and the test result.

  19. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever.

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-05-26

    hypothetical cohort of 1000 patients presenting with fever where 30% (300 patients) have enteric fever, on average Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results will miss the diagnosis in 66 patients with enteric fever, TUBEX will miss 66, and Test-It Typhoid and prototype (KIT) tests will miss 93. In the 700 people without enteric fever, the number of people incorrectly diagnosed with enteric fever would be 161 with Typhidot tests, 91 with TUBEX, and 70 with Test-It Typhoid and prototype (KIT) tests. The CIs around these estimates were wide, with no difference in false positive results shown between tests.The quality of the data for each study was evaluated using a standardized checklist called QUADAS-2. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low. In 37 studies that evaluated the diagnostic accuracy of RDTs for enteric fever, few studies were at a low risk of bias. The three main RDT tests and variants had moderate diagnostic accuracy. There was no evidence of a difference between the average sensitivity and specificity of the three main RDT tests. More robust evaluations of alternative RDTs for enteric fever are needed.

  20. Modern diagnostic capabilities for vasospastic angina diagnostics (intracoronary provocative testing

    Directory of Open Access Journals (Sweden)

    А. А. Обединский

    2017-04-01

    Full Text Available This review is devoted to a topical problem of modern cardiology – techniques of diagnosing vasospastic angina. The results of retrospective and prospective studies on the efficacy and safety of vasospastic angina diagnostics are reviewed. The literature on the prevalence, progression and treatment of this pathology is discussed.Received 13 January 2017. Accepted 6 February 2017.Financing: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest.

  1. Diagnostic accuracy of patch test in children with food allergy.

    Science.gov (United States)

    Caglayan Sozmen, Sule; Povesi Dascola, Carlotta; Gioia, Edoardo; Mastrorilli, Carla; Rizzuti, Laura; Caffarelli, Carlo

    2015-08-01

    The gold standard test for confirming whether a child has clinical hypersensitivity reactions to foods is the oral food challenge. Therefore, there is increasing interest in simpler diagnostic markers of food allergy, especially in children, to avoid oral food challenge. The goal of this study was to assess the diagnostic accuracy of atopy patch test in comparison with oral food challenge. We investigated 243 children (mean age, 51 months) referred for evaluation of suspected egg or cow's milk allergy. Skin prick test and atopy patch test were carried out, and after a 2 weeks elimination diet, oral food challenge was performed. Two hundred and forty-three children underwent OFC to the suspected food. We found clinically relevant food allergies in 40 (65%) children to egg and in 22 (35%) to cow's milk. The sensitivity of skin prick test for both milk and egg was 92%, specificity 91%, positive predictive value 35%, and negative predictive value of 93%. Sensitivity, specificity, positive predictive value, and negative predictive value of atopy patch test for both milk and egg were 21%, 73%, 20%, and 74%, respectively. Our study suggests that there is insufficient evidence for the routine use of atopy patch test for the evaluation of egg and cow's milk allergy. OFC remains gold standard for the diagnosis of egg and milk allergy even in the presence of high costs in terms of both time and risks during application. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-01-01

    % CI 2% to 28%), but other comparisons did not show a difference at the 95% level of CIs. In a hypothetical cohort of 1000 patients presenting with fever where 30% (300 patients) have enteric fever, on average Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results will miss the diagnosis in 66 patients with enteric fever, TUBEX will miss 66, and Test-It Typhoid and prototype (KIT) tests will miss 93. In the 700 people without enteric fever, the number of people incorrectly diagnosed with enteric fever would be 161 with Typhidot tests, 91 with TUBEX, and 70 with Test-It Typhoid and prototype (KIT) tests. The CIs around these estimates were wide, with no difference in false positive results shown between tests. The quality of the data for each study was evaluated using a standardized checklist called QUADAS-2. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low. Authors' conclusions In 37 studies that evaluated the diagnostic accuracy of RDTs for enteric fever, few studies were at a low risk of bias. The three main RDT tests and variants had moderate diagnostic accuracy. There was no evidence of a difference between the average sensitivity and specificity of the three main RDT tests. More robust evaluations of alternative RDTs for enteric fever are needed. The accuracy of rapid diagnostic tests for detecting typhoid and paratyphoid (enteric) fever Cochrane researchers assessed the accuracy of commercially-available rapid diagnostic tests and their prototypes (including TUBEX, Typhidot, Typhidot-M, Test-it Typhoid, and other tests) for detecting typhoid and paratyphoid (enteric) fever in people living in countries where the estimated number of individuals with the disease at any one time is greater than 10 per 100,000 population. If accurate, they could replace the current World Health Organization (WHO)-recommended diagnostic test: culture (growing the bacteria that causes the

  3. Diagnostic accuracy of the Rivalta test for feline infectious peritonitis.

    Science.gov (United States)

    Fischer, Yvonne; Sauter-Louis, Carola; Hartmann, Katrin

    2012-12-01

    The Rivalta test has been used routinely in Europe to diagnose feline infectious peritonitis (FIP) in cats with effusions, but its diagnostic accuracy is uncertain. The objectives of this study were to calculate sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values of the Rivalta test for FIP and to identify correlations between a positive Rivalta test and variables measured in effusion fluid and peripheral blood. In this retrospective study, medical records of cats with effusions were reviewed, and cats with conclusive results for the Rivalta test were included. The prevalence of FIP in this population was determined, and sensitivity, specificity, and PPV and NPV of the Rivalta test were calculated. Variables measured in effusion fluid and peripheral blood were compared between cats that had positive or negative Rivalta tests using the Mann-Whitney U-test and multivariate analysis. Of 851 cats with effusions, 782 had conclusively positive or negative results for the Rivalta test. A definitive final diagnosis was made in 497 of these cats. Prevalence of FIP in cats with effusion and a conclusive Rivalta test result was 34.6%. The Rivalta test had a sensitivity of 91.3%, specificity of 65.5%, PPV of 58.4%, and NPV of 93.4% for the diagnosis of FIP. These values increased when cats with lymphoma or bacterial infections were excluded, or when only cats ≤ 2 years were considered. Increased effusion cholesterol concentration and specific gravity as well as decreased serum albumin:globulin ratio and hyperbilirubinemia were positively correlated with positive Rivalta test results. Sensitivity, specificity, and PPV of the Rivalta test for the diagnosis of FIP were lower than previously reported except when used in young cats. The components in effusions that lead to a positive Rivalta test remain unknown, but the positivity is not simply related to high total protein concentration. © 2012 American Society for Veterinary Clinical Pathology.

  4. Technology diffusion and diagnostic testing for prostate cancer

    Science.gov (United States)

    Schroeck, Florian R.; Kaufman, Samuel R.; Jacobs, Bruce L.; Skolarus, Ted A.; Miller, David C.; Weizer, Alon Z.; Montgomery, Jeffrey S.; Wei, John T.; Shahinian, Vahakn B.; Hollenbeck, Brent K.

    2013-01-01

    Purpose While the dissemination of robotic prostatectomy and intensity-modulated radiotherapy (IMRT) may fuel increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with receipt of prostate specific antigen (PSA) testing and prostate biopsy. Methods In this retrospective cohort study, we included 117,857 men age 66 and older from the 5% sample of Medicare beneficiaries living in the Surveillance Epidemiology and End Results (SEER) areas from 2003 – 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or IMRT per population in a healthcare market (i.e., hospital referral region). We assessed the association of technology penetration with rates of PSA testing and prostate biopsy with generalized estimating equations. Results High technology penetration was associated with increased rates of PSA testing (442 versus 425 per 1,000 person-years, pimpact of technology penetration on PSA testing and prostate biopsy was much smaller than the effect of age, race, and comorbidity (e.g., PSA testing rate per 1,000 person-years: 485 versus 373 for men with only one versus 3+ co-morbid conditions, ppenetration was associated with slightly higher rates of PSA testing and no change in prostate biopsy rates. Collectively, our findings temper concerns that adoption of new technology accelerates diagnostic testing for prostate cancer. PMID:23669564

  5. Concordance in diagnostic testing for respiratory pathogens of bighorn sheep

    Science.gov (United States)

    Walsh, Daniel P.; Cassirer, E. Frances; Bonds, Michael D.; Brown, Daniel R.; Edwards, William H.; Weiser, Glen C.; Drew, Mark L.; Briggs, Robert E.; Fox, Karen A.; Miller, Michael W.; Shanthalingam, Sudarvili; Srikumaran, Subramaniam; Besser, Thomas E.

    2016-01-01

    Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack of appropriate standardized commercial kits. Results of diagnostic testing may also be called into question when investigators report different etiologies for disease outbreaks, despite similar clinical and pathologic findings. To evaluate reliability of diagnostic testing for respiratory pathogens of bighorn sheep (Ovis canadensis), we conducted a series of ring tests across 6 laboratories routinely involved in detection of Mycoplasma ovipneumoniae, Pasteurellaceae, lktA (the Pasteurellaceae gene encoding leukotoxin), and 3 reference laboratories. Consistency of results for replicate samples within laboratories was high (median agreement = 1.0). Agreement between laboratories was high for polymerase chain reaction (PCR) detection of M. ovipneumoniae and culture isolation of Mannheimia spp. and Bibersteinia trehalosi(median agreement = 0.89–0.95, Kappa = 0.65–0.74), and lower for PCR detection of Mannheimiaspp. lktA (median agreement = 0.58, Kappa = 0.12). Most errors on defined status samples were false negatives, suggesting test sensitivity was a greater problem than specificity. However, tests for M. haemolytica and lktA yielded some false positive results. Despite differences in testing protocols, median agreement among laboratories and correct classification of controls for most agents was ≥0.80, meeting or exceeding the standard required by federal proficiency testing programs. This information is valuable for interpreting test results, laboratory quality assessments, and advancing diagnosis of respiratory disease in wild sheep. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  6. Diagnostic validation of selected serological tests for detecting scrub typhus.

    Science.gov (United States)

    Koraluru, Munegowda; Bairy, Indira; Varma, Muralidhar; Vidyasagar, Sudha

    2015-07-01

    Clinical diagnosis of scrub typhus is often difficult because the symptoms are very similar to those of other febrile illness such as dengue, leptospirosis, malaria and other viral hemorrhagic fevers. Though better diagnostic tests are available for rickettsial diseases and scrub typhus elsewhere, the Weil-Felix test is still commonly used in India, mainly because microimmunofluorescence assays (M-IFA) were not available in India till recently and relevant staff had insufficient training. The present study was performed to investigate the performance of M-IFA, IgM ELISA, and Weil-Felix test on 546 non-repeated serum samples from subjects suspected of having scrub typhus. One hundred and forty-three of these 546 samples were positive by M-IFA; these cases were also confirmed clinically to have scrub typhus based on their dramatic responses to doxycycline therapy. IgM ELISA was positive in 122 of the 143 M-IFA positive cases and the Weil-Felix test in 96. Though the Weil-Felix test is a heterophile agglutination test, it was found in this study to have good specificity but far too little sensitivity to use as a routine diagnostic test. IgM ELISA can be a good substitute for M-IFA. Incorporation of multiple prototype antigens on M-IFA slides is likely one of the reasons for its superior performance. As newer and better diagnostic assays become available for scrub typhus diagnosis in developed countries, it will be imperative to also use such tests in other endemic countries to prevent over- or under-diagnosis of scrub typhus. © 2015 The Societies and Wiley Publishing Asia Pty Ltd.

  7. Progeria Research Foundation Diagnostic Testing Program

    Science.gov (United States)

    ... Share the DVD Meet the Kids in the Movie Bring LATS to the classroom! Close News/Events ... this could severely affect their research results and interpretation. Through the PRF Diagnostics Program, each cell line ...

  8. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    Science.gov (United States)

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  9. Remote Testing of Timed Specifications

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Mikucionis, Marius

    2013-01-01

    We present a study and a testing framework on black box remote testing of real-time systems using UPPAAL TIGA. One of the essential challenges of remote testing is the communication latency between the Tester and the System Under Test (IUT) that may lead to interleaving of inputs and outputs. Thi...

  10. Quantifying the Accuracy of a Diagnostic Test or Marker

    NARCIS (Netherlands)

    Linnet, Kristian; Bossuyt, Patrick M. M.; Moons, Karel G. M.; Reitsma, Johannes B. R.

    2012-01-01

    BACKGROUND: In recent years, increasing focus has been directed to the methodology for evaluating (new) tests or biomarkers. A key step in the evaluation of a diagnostic test is the investigation into its accuracy. CONTENT: We reviewed the literature on how to assess the accuracy of diagnostic

  11. YOUTH BASKETBALL SPECIFIC EFFORT TEST

    Directory of Open Access Journals (Sweden)

    Philippe Campillo

    2004-12-01

    Full Text Available The test, as it is presented, must be modified to produce more pertinent results. The measure before the maximum jumps in RJ can also show at what intensity the athletes produce the jump repetitions. The knowledge of the maximal performance during a jump constitutes a reference with which one can evaluate a subject's commitment and efficiency during the test. The results of the study show that this type of test protocol can be a good method to evaluate the physical condition of an athlete during training.

  12. In Search of Optimal Cognitive Diagnostic Model(s) for ESL Grammar Test Data

    Science.gov (United States)

    Yi, Yeon-Sook

    2017-01-01

    This study compares five cognitive diagnostic models in search of optimal one(s) for English as a Second Language grammar test data. Using a unified modeling framework that can represent specific models with proper constraints, the article first fit the full model (the log-linear cognitive diagnostic model, LCDM) and investigated which model…

  13. Diagnostic Tests for Entering and Departing Undergraduate Students

    Science.gov (United States)

    Waltham, Chris; Kotlicki, A.

    2006-12-01

    A diagnostic test administered at the start of a class should test basic concepts which are recognized as course prerequisites. The questions should not be over-packaged: e.g. students should be required to create models, rather than this being done for them each time. Students should be allowed great latitude in their answers, so we can discover what they are thinking. When administered at the end of a class the goals should be similar: testing concepts taught in the class itself and the retention of necessary concepts from previous classes. Great care has to be taken to avoid teaching to the test. In assessing an entire program, for example an undergraduate majors degree in physics, then one looks for very general skills and knowledge not specific to any one course. The purpose of an undergraduate degree in physics (or indeed any science) is to equip the students with a set of problem-solving skills and basic knowledge which can be applied in a large variety of workplace settings and to allow that student to contribute to civic society as a science-literate person. The creator of any diagnostic test should always have these big goals in mind. We have developed a set of questions which we think fulfill these criteria, yet are not specific to any particular level of science education. They have been administered to students in secondary schools across Canada, incoming first-year science students and final-year physics students at the University of British Columbia. The results will be presented.

  14. What is the role of clinical tests and ultrasound in acetabular labral tear diagnostics?

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mechlenburg, Inger; Gelineck, John

    2009-01-01

    BACKGROUND AND PURPOSE: An acetabular labral tear is a diagnostic challenge. Various clinical tests have been described, but little is known about their diagnostic sensitivity and specificity. We investigated the diagnostic validity of clinical tests and ultrasound as compared with MR arthrography...... no or only slight signs of osteoarthritis (Tönnis grade 0-1). RESULTS: MR arthrography identified labral tears in 17 of the 18 hips. Ultrasound had a sensitivity of 94%, a positive predictive value of 94%, and was false negative in only 1 case compared to MR arthrography. The impingement test had the best...... diagnostic ability of the clinical tests, with a sensitivity of 59% and a specificity of 100%. The positive predictive value was 100% while the negative predictive value was 13%. INTERPRETATION: The impingement test is helpful in identifying acetabular labral tears. If this test is negative and if a labral...

  15. Final Empirical Test Case Specification

    DEFF Research Database (Denmark)

    Kalyanova, Olena; Heiselberg, Per

    This document includes the empirical specification on the IEA task of evaluation building energy simulation computer programs for the Double Skin Facades (DSF) constructions. There are two approaches involved into this procedure, one is the comparative approach and another is the empirical one....

  16. Better Tests, Better Care: Improved Diagnostics for Infectious Diseases

    Science.gov (United States)

    Caliendo, Angela M.; Gilbert, David N.; Ginocchio, Christine C.; Hanson, Kimberly E.; May, Larissa; Quinn, Thomas C.; Tenover, Fred C.; Alland, David; Blaschke, Anne J.; Bonomo, Robert A.; Carroll, Karen C.; Ferraro, Mary Jane; Hirschhorn, Lisa R.; Joseph, W. Patrick; Karchmer, Tobi; MacIntyre, Ann T.; Reller, L. Barth; Jackson, Audrey F.

    2013-01-01

    In this IDSA policy paper, we review the current diagnostic landscape, including unmet needs and emerging technologies, and assess the challenges to the development and clinical integration of improved tests. To fulfill the promise of emerging diagnostics, IDSA presents recommendations that address a host of identified barriers. Achieving these goals will require the engagement and coordination of a number of stakeholders, including Congress, funding and regulatory bodies, public health agencies, the diagnostics industry, healthcare systems, professional societies, and individual clinicians. PMID:24200831

  17. A Ribeiroia spp. (Class: Trematoda) - Specific PCR-based diagnostic

    Science.gov (United States)

    Reinitz, David M.; Yoshino, T.P.; Cole, Rebecca A.

    2007-01-01

    Increased reporting of amphibian malformations in North America has been noted with concern in light of reports that amphibian numbers and species are declining worldwide. Ribeiroia ondatrae has been shown to cause a variety of types of malformations in amphibians. However, little is known about the prevalence of R. ondatrae in North America. To aid in conducting field studies of Ribeiroia spp., we have developed a polymerase chain reaction (PCR)-based diagnostic. Herein, we describe the development of an accurate, rapid, simple, and cost-effective diagnostic for detection of Ribeiroia spp. infection in snails (Planorbella trivolvis). Candidate oligonucleotide primers for PCR were designed via DNA sequence analyses of multiple ribosomal internal transcribed spacer-2 regions from Ribeiroia spp. and Echinostoma spp. Comparison of consensus sequences determined from both genera identified areas of sequence potentially unique to Ribeiroia spp. The PCR reliably produced a diagnostic 290-base pair (bp) product in the presence of a wide concentration range of snail or frog DNA. Sensitivity was examined with DNA extracted from single R. ondatrae cercaria. The single-tube PCR could routinely detect less than 1 cercariae equivalent, because DNA isolated from a single cercaria could be diluted at least 1:50 and still yield a positive result via gel electrophoresis. An even more sensitive nested PCR also was developed that routinely detected 100 fg of the 290-bp fragment. The assay did not detect furcocercous cercariae of certain Schistosomatidae, Echinostoma sp., or Sphaeridiotrema globulus nor adults of Clinostomum sp. or Cyathocotyle bushiensis. Field testing of 137 P. trivolvis identified 3 positives with no overt environmental cross-reactivity, and results concurred with microscopic examinations in all cases. ?? American Society of Parasitologists 2007.

  18. Diagnostic tests in gastroesophageal reflux disease (GERD)

    International Nuclear Information System (INIS)

    Hani de Ardila, Albis

    2009-01-01

    The true prevalence of gastroesophageal reflux disease (GERD) is difficult to establish despite that an estimated 11% of the U.S. population experiencing heartburn daily or 30% every three days (1), perhaps due to that the disease can cause many symptoms, both typical and atypical as heartburn or chest pain, among others. Multiple techniques for measuring reflux have been used, and many authors (1-3) have asked why this situation, possibly because the techniques measure and quantify the basic pathophysiologic problem disease, the time of exposure of the esophagus distal to the gastric juice, because the measures are quantitatively related to the degree of esophageal mucosal injury, or because the episodes of exposure to gastric juice correlated with the patient's symptoms. As said Richter (4) m any times these studies are unnecessary because the history is sufficiently revealing to identify the presence of GERD. But the clinician must decide which test you choose to carry a diagnosis of a reliable, timely and cost-effective . But we cannot rely on the presence of symptoms to diagnosis, because we incur the overdiagnosis in a considerable number of individuals, the sensitivity set for the typical symptoms as heartburn is 68% and specificity was 63% (2), which leads us to conclude that atypical symptoms should be investigated as they may relate to functional dyspepsia rather than GERD. It is also clear that the severity and frequency of symptoms in any way correlates with the presence or absence of esophagitis, patients with erosive esophagitis are more severe disease and increased risk of developing complications. The persistent exposure of the esophagus to gastric juice does not cause mucosal injury in all individuals, therefore, it is possible to define the disease by the presence of mucosal injury, while endoscopy is able to define the mucosal injury caused by the reflux can also lead to false conclusions, such as those patients with symptoms of GERD who have no

  19. The diagnostic adaptive behavior scale: evaluating its diagnostic sensitivity and specificity.

    Science.gov (United States)

    Balboni, Giulia; Tassé, Marc J; Schalock, Robert L; Borthwick-Duffy, Sharon A; Spreat, Scott; Thissen, David; Widaman, Keith F; Zhang, Dalun; Navas, Patricia

    2014-11-01

    The Diagnostic Adaptive Behavior Scale (DABS) was constructed with items across three domains--conceptual, social, and practical adaptive skills--and normed on a representative sample of American individuals from 4 to 21 years of age. The DABS was developed to focus its assessment around the decision point for determining the presence or absence of significant limitations of adaptive behavior for the diagnosis of Intellectual Disability (ID). The purpose of this study, which was composed of 125 individuals with and 933 without an ID-related diagnosis, was to determine the ability of the DABS to correctly identify the individuals with and without ID (i.e., sensitivity and specificity). The results indicate that the DABS sensitivity coefficients ranged from 81% to 98%, specificity coefficients ranged from 89% to 91%, and that the Area Under the Receiver Operating Characteristic Curve were excellent or good. These results indicate that the DABS has very good levels of diagnostic efficiency. Copyright © 2014. Published by Elsevier Ltd.

  20. Diagnostic accuracy of temporomandibular disorder pain tests: a multicenter study

    NARCIS (Netherlands)

    Visscher, C.M.; Naeije, M.; de Laat, A.; Michelotti, A.; Nilner, M.; Craane, B.; Ekberg, E.; Farella, M.; Lobbezoo, F.

    2009-01-01

    AIMS: To estimate the diagnostic accuracy of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) clinical examination and of the dynamic/static tests for the recognition of TMD pain. Since the diagnosis of TMD pain is especially complicated in persistent orofacial pain

  1. Diagnostic tests for Helicobacter pylori : A prospective evaluation of their accuracy, without selecting a single test as the gold standard

    NARCIS (Netherlands)

    Thijs, J C; van Zwet, A A; Thijs, W J; Oey, H B; Karrenbeld, A; Stellaard, F; Luijt, D S; Meyer, B C; Kleibeuker, J H

    1996-01-01

    OBJECTIVE: To assess the accuracy of six commonly used diagnostic tests for Helicobacter pylori in a prospective study without using any specific test as the gold standard (the patient was regarded as H. pylori-infected if two or more tests, whatever their nature, were positive). METHODS: In 105

  2. Prostate-specific antigen testing accuracy in community practice

    Directory of Open Access Journals (Sweden)

    Adams-Cameron Meg

    2002-10-01

    Full Text Available Abstract Background Most data on prostate-specific antigen (PSA testing come from urologic cohorts comprised of volunteers for screening programs. We evaluated the diagnostic accuracy of PSA testing for detecting prostate cancer in community practice. Methods PSA testing results were compared with a reference standard of prostate biopsy. Subjects were 2,620 men 40 years and older undergoing (PSA testing and biopsy from 1/1/95 through 12/31/98 in the Albuquerque, New Mexico metropolitan area. Diagnostic measures included the area under the receiver-operating characteristic curve, sensitivity, specificity, and likelihood ratios. Results Cancer was detected in 930 subjects (35%. The area under the ROC curve was 0.67 and the PSA cutpoint of 4 ng/ml had a sensitivity of 86% and a specificity of 33%. The likelihood ratio for a positive test (LR+ was 1.28 and 0.42 for a negative test (LR-. PSA testing was most sensitive (90% but least specific (27% in older men. Age-specific reference ranges improved specificity in older men (49% but decreased sensitivity (70%, with an LR+ of 1.38. Lowering the PSA cutpoint to 2 ng/ml resulted in a sensitivity of 95%, a specificity of 20%, and an LR+ of 1.19. Conclusions PSA testing had fair discriminating power for detecting prostate cancer in community practice. The PSA cutpoint of 4 ng/ml was sensitive but relatively non-specific and associated likelihood ratios only moderately revised probabilities for cancer. Using age-specific reference ranges and a PSA cutpoint below 4 ng/ml improved test specificity and sensitivity, respectively, but did not improve the overall accuracy of PSA testing.

  3. Emerging diagnostic tests for vitreoretinal lymphoma.

    Science.gov (United States)

    Dawson, Abby C; Williams, Keryn A; Appukuttan, Binoy; Smith, Justine R

    2018-04-19

    Vitreoretinal lymphoma, which most commonly is diffuse large B cell non-Hodgkin in type, is a rare cancer with high morbidity and high mortality. Making a tissue diagnosis of vitreoretinal lymphoma is a major challenge for clinicians due to biological and technical factors. Yet, the delay in start of treatment may have vision- and life- threatening consequences, and there is considerable interest in the application of molecular assays to improve the accuracy of the diagnostic process: detection of a clonal immunoglobulin heavy chain rearrangements in lymphoma cells by polymerase chain reaction; measurement of vitreous or aqueous interleukin-10 protein levels in ocular fluids; and identification of mutations in the myeloid differentiation primary response gene 88 in tumour cells. In this article, we review the historical development and current application of each of these molecular methods. We also discuss future opportunities for the molecular diagnosis of vitreoretinal lymphoma through next generation sequencing technologies. This article is protected by copyright. All rights reserved.

  4. Learning Digital Test and Diagnostics via Internet

    Directory of Open Access Journals (Sweden)

    Heinz-Dietrich Wuttke

    2007-02-01

    Full Text Available An environment targeted to e-learning is presented for teaching design and test of electronic systems. The environment consists of a set of Java applets, and of web based access to the hardware equipments, which can be used in the classroom, for learning at home, in laboratory research and training, or for carrying out testing of students during exams. The tools support university courses on digital electronics, computer hardware, testing and design for testability to learn by hands-on exercises how to design digital systems, how to make them testable, how to build self-testing systems, how to generate test patterns, how to analyze the quality of tests, and how to localize faults in hardware. The tasks chosen for hands-on training represent simultaneously research problems, which allow to fostering in students critical thinking, problem solving skills and creativity.

  5. Concordance in diagnostic testing for respiratory pathogens of Bighorn Sheep

    Science.gov (United States)

    Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack ...

  6. Formaldehyde concentration in diagnostic patch testing

    DEFF Research Database (Denmark)

    Trattner, A; Johansen, J D; Menné, T

    1998-01-01

    Exposure to formaldehyde is common from both consumer products and industry. The reliability of the patch test is essential for the diagnosis of formaldehyde allergy as it is difficult to suspect from the patient's history. The recommended formaldehyde patch test concentration has been reduced over...

  7. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  8. New diagnostic tests of GH reserve.

    Science.gov (United States)

    Martul, P; Pineda, J; Pombo, M; Peñalva, A; Bokser, L; Dieguez, C

    1993-01-01

    Pharmacological tests are essential for the diagnosis of growth hormone (GH) insufficiency. Obesity is a pathological state associated with blunted GH response to all the classical stimuli tested. In the present study, three new pharmacological stimuli for GH reserve were evaluated in three groups of subjects: Normal, GH-insufficient and normal growing obese children. Dexamethasone provokes a clear GH-response in normal children, whereas the response in the other 2 groups of patients is significantly diminished. Galanin-induced GH-secretion is significantly higher in normal than in obese children. GHRP-6 causes a potent GH release in normal children, higher than in GH-insufficiency or obesity. The overlap shown between GH-insufficient patients and normal children reduces the usefulness of the tests. Similar to the classical stimuli, the response to these new tests is also decreased in obesity.

  9. Role of diagnostic tests in esophageal evaluation

    International Nuclear Information System (INIS)

    Silverstein, B.D.; Pope, C.E. II

    1980-01-01

    In the evaluation of esophageal disease, the appropriate question must be asked before the correct tests can be selected. Reflux can be demonstrated by radiologic methods, pH testing or radioisotopic techniques. Esophageal mucosal damage is best evaluated by x-ray, endoscopy, or biopsy. Chest pain is demonstrated by acid infusion or by manometry. Two algorithms are presented for the evaluation of chest pain and reflux symptoms

  10. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    Science.gov (United States)

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  11. Prostate-Specific Antigen (PSA) Test

    Science.gov (United States)

    ... Cancer Prostate Cancer Screening Research Prostate-Specific Antigen (PSA) Test On This Page What is the PSA ... parts of the body before being detected. The PSA test may give false-positive or false-negative ...

  12. Efficient strategies to find diagnostic test accuracy studies in kidney journals.

    Science.gov (United States)

    Rogerson, Thomas E; Ladhani, Maleeka; Mitchell, Ruth; Craig, Jonathan C; Webster, Angela C

    2015-08-01

    Nephrologists looking for quick answers to diagnostic clinical questions in MEDLINE can use a range of published search strategies or Clinical Query limits to improve the precision of their searches. We aimed to evaluate existing search strategies for finding diagnostic test accuracy studies in nephrology journals. We assessed the accuracy of 14 search strategies for retrieving diagnostic test accuracy studies from three nephrology journals indexed in MEDLINE. Two investigators hand searched the same journals to create a reference set of diagnostic test accuracy studies to compare search strategy results against. We identified 103 diagnostic test accuracy studies, accounting for 2.1% of all studies published. The most specific search strategy was the Narrow Clinical Queries limit (sensitivity: 0.20, 95% CI 0.13-0.29; specificity: 0.99, 95% CI 0.99-0.99). Using the Narrow Clinical Queries limit, a searcher would need to screen three (95% CI 2-6) articles to find one diagnostic study. The most sensitive search strategy was van der Weijden 1999 Extended (sensitivity: 0.95; 95% CI 0.89-0.98; specificity 0.55, 95% CI 0.53-0.56) but required a searcher to screen 24 (95% CI 23-26) articles to find one diagnostic study. Bachmann 2002 was the best balanced search strategy, which was sensitive (0.88, 95% CI 0.81-0.94), but also specific (0.74, 95% CI 0.73-0.75), with a number needed to screen of 15 (95% CI 14-17). Diagnostic studies are infrequently published in nephrology journals. The addition of a strategy for diagnostic studies to a subject search strategy in MEDLINE may reduce the records needed to screen while preserving adequate search sensitivity for routine clinical use. © 2015 Asian Pacific Society of Nephrology.

  13. A diagnostic test for apraxia in stroke patients: internal consistency and diagnostic value.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, F.C.; Kinebanian, A.

    1999-01-01

    The internal consistency and the diagnostic value of a test for apraxia in patients having had a stroke are presented. Results indicate that the items of the test form a strong and consistent scale: Cronbach's alpha as well as the results of a Mokken scale analysis present good reliability and good

  14. Rapid Diagnostic Tests for Malaria: A Review

    Science.gov (United States)

    2005-06-01

    4.92% 0% 100% [25] France** 557 15.5% 1.3%*** 100% 14.3% 1.3%*** 100% [26] Kuwait** 240 0% - 75.4% - - - [27] Peru 72 - - - 7.7% 0% 100% [28...expression of aldolase isoenzymes in the rodent malaria parasite Plasmodium berghei. Mol. Biochem. Parasitol., 52, 15-27. [21] Cloonan, N., Fischer...R. L. (2003). Performance of an immunochromatography test for vivax malaria in the Amazon region, Brazil. Rev. Saude Publica, 37, 390-392. [69

  15. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false

  16. Characterization of the Goubau line for testing beam diagnostic instruments

    Science.gov (United States)

    Kim, S. Y.; Stulle, F.; Sung, C. K.; Yoo, K. H.; Seok, J.; Moon, K. J.; Choi, C. U.; Chung, Y.; Kim, G.; Woo, H. J.; Kwon, J.; Lee, I. G.; Choi, E. M.; Chung, M.

    2017-12-01

    One of the main characteristics of the Goubau line is that it supports a low-loss, non-radiated surface wave guided by a dielectric-coated metal wire. The dominant mode of the surface wave along the Goubau line is a TM01 mode, which resembles the pattern of the electromagnetic fields induced in the metallic beam pipe when the charged particle beam passes through it. Therefore, the Goubau line can be used for the preliminary bench test and performance optimization of the beam diagnostic instruments without requiring charged particle beams from the accelerators. In this paper, we discuss the basic properties of the Goubau line for testing beam diagnostic instruments and present the initial test results for button-type beam position monitors (BPMs). The experimental results are consistent with the theoretical estimations, which indicates that Goubau line allows effective testing of beam diagnostic equipment.

  17. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    Science.gov (United States)

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  18. Nonparametric predictive inference for combining diagnostic tests with parametric copula

    Science.gov (United States)

    Muhammad, Noryanti; Coolen, F. P. A.; Coolen-Maturi, T.

    2017-09-01

    Measuring the accuracy of diagnostic tests is crucial in many application areas including medicine and health care. The Receiver Operating Characteristic (ROC) curve is a popular statistical tool for describing the performance of diagnostic tests. The area under the ROC curve (AUC) is often used as a measure of the overall performance of the diagnostic test. In this paper, we interest in developing strategies for combining test results in order to increase the diagnostic accuracy. We introduce nonparametric predictive inference (NPI) for combining two diagnostic test results with considering dependence structure using parametric copula. NPI is a frequentist statistical framework for inference on a future observation based on past data observations. NPI uses lower and upper probabilities to quantify uncertainty and is based on only a few modelling assumptions. While copula is a well-known statistical concept for modelling dependence of random variables. A copula is a joint distribution function whose marginals are all uniformly distributed and it can be used to model the dependence separately from the marginal distributions. In this research, we estimate the copula density using a parametric method which is maximum likelihood estimator (MLE). We investigate the performance of this proposed method via data sets from the literature and discuss results to show how our method performs for different family of copulas. Finally, we briefly outline related challenges and opportunities for future research.

  19. A comparison of rapid diagnostic testing (by plasmodium lactate ...

    African Journals Online (AJOL)

    Background: The World Health Organization (WHO) considers early and rapid diagnosis as one of the strategies to control malaria. This study compared the performance of Quantitative Buffy Coat (QBC) test and the Plasmodium lactate dehydrogenase (pLDH) rapid diagnostic test (RDT) with microscopy as the gold ...

  20. Diagnostic value of serologic tests in celiac screening

    Directory of Open Access Journals (Sweden)

    Hosein Saneian

    2012-01-01

    Conclusions: According to our study results, there is no correlation between gastrointestinal symptoms such as vomiting diarrhea, anorexia, bulimia, and failure to thrive (FFT with celiac. TTG was the best screening test method to diagnose celiac disease and other tests such as AGA and EMA do not have high diagnostic value.

  1. SPS Dipole Multipactor Test and TEWave Diagnostics

    CERN Document Server

    Caspers, F; Edwards, P; Federmann, S; Holz, M; Taborelli, M

    2013-01-01

    Electron cloud accumulation in particle accelerators can be mitigated by coating the vacuum beam pipe with thin films of low secondary electron yield (SEY) material. The SEY of small coated samples are usually measured in the laboratory. To further test the properties of different coating materials, RF-induced multipacting in a coaxial waveguide configuration can be performed. The technique is applied to two main bending dipoles of the SPS, where the RF power is fed through a tungsten wire stretched along the vacuum chamber (6.4 m). A dipole with a bare stainless steel chamber shows a clear power threshold initiating an abrupt rise in reflected power and pressure. The effect is enhanced at RF frequencies corresponding to electron cyclotron resonances for given magnetic fields. Preliminary results show that the dipole with a carbon coated vacuum chamber does not exhibit any pressure rise or reflected RF power up to the maximum available input power. In the case of a large scale coating production this techniqu...

  2. A coproantigen diagnostic test for Strongyloides infection.

    Directory of Open Access Journals (Sweden)

    Alex M Sykes

    Full Text Available Accurate diagnosis of infection with the parasite Strongyloides stercoralis is hampered by the low concentration of larvae in stool, rendering parasitological diagnosis insensitive. Even if the more sensitive agar plate culture method is used repeated stool sampling is necessary to achieve satisfactory sensitivity. In this manuscript we describe the development of a coproantigen ELISA for diagnosis of infection. Polyclonal rabbit antiserum was raised against Strongyloides ratti excretory/secretory (E/S antigen and utilized to develop an antigen capture ELISA. The assay enabled detection of subpatent rodent S. ratti and human S. stercoralis infection. No cross-reactivity was observed with purified E/S from Schistosoma japonicum, the hookworms Ancylostoma caninum, A. ceylanicum, nor with fecal samples collected from rodents harboring Trichuris muris or S. mansoni infection. Strongyloides coproantigens that appear stable when frozen as formalin-extracted fecal supernatants stored at -20 °C remained positive up to 270 days of storage, whereas supernatants stored at 4 °C tested negative. These results indicate that diagnosis of human strongyloidiasis by detection of coproantigen is an approach worthy of further development.

  3. Project NEO Specific Impulse Testing Solutions

    Science.gov (United States)

    Baffa, Bill

    2018-01-01

    The Neo test stand is currently configured to fire a horizontally mounted rocket motor with up to 6500 lbf thrust. Currently, the Neo test stand can measure flow of liquid propellant and oxidizer, pressures residing in the closed system up to the combustion chamber. The current configuration does not have the ability to provide all data needed to compute specific impulse. This presents three methods to outfit the NEO test fixture with instrumentation allowing for calculation of specific impulse.

  4. UREA BREATH TEST – ITS ROLE IN DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    Joško Osredkar

    2004-01-01

    Full Text Available Background. Each year many patients visit their physicians complaining of digestive symptoms, most commonly functional dyspepsia (»indigestion« or gastroesophageal reflux (»heartburn«. However, many patients with abdominal discomfort are actually suffering from gastric or duodenal ulcers that are commonly caused by H. pylori and thus are curable. Clearing the infection usually heals the ulcer and prevents relapse, so an accurate diagnosis is important. There are several options for diagnosing H. pylori infection: serology to detect antibodies against the bacterium; endoscopic biopsy for urease testing (H. pylori produce a urease that breaks down urea to ammonia and carbon dioxide; histology with special stains; or culture. Unfortunately, these procedures are invasive, expensive and not always accurate. Serological tests require a blood sample and tell only that a patient has been exposed to H. pylori at some time in the past, but not whether the patient is currently infected. Endoscopy and biopsy can detect current infection — the CLO test urease test allows rapid detection of H. pylori in gastric biopsy specimens — but endoscopy and biopsy are unpleasant medical procedures.Recently, noninvasive, sensitive, specific, easy to perform and patient’s well accepted methods had been developed known as urea breath test (UBT. When an infected person swallows a dose of urea labeled with an isotope of carbon — carbon-13 (13C or carbon-14 (14C – H. pylori in the gastric mucosa break down the labeled urea to form ammonia and labeled carbon dioxide. The carbon dioxide is absorbed into the bloodstream and excreted via the lungs. The patient then exhales into a device that measures the level of carbon dioxide. The urea breath test is specific for H. pylori (it detects only urease-producing bacteria, it is sensitive (the labeled urea reaches a large area of the stomach and thus reflects total gastric urease activity and the results can be

  5. Variation of a test's sensitivity and specificity with disease prevalence.

    Science.gov (United States)

    Leeflang, Mariska M G; Rutjes, Anne W S; Reitsma, Johannes B; Hooft, Lotty; Bossuyt, Patrick M M

    2013-08-06

    Anecdotal evidence suggests that the sensitivity and specificity of a diagnostic test may vary with disease prevalence. Our objective was to investigate the associations between disease prevalence and test sensitivity and specificity using studies of diagnostic accuracy. We used data from 23 meta-analyses, each of which included 10-39 studies (416 total). The median prevalence per review ranged from 1% to 77%. We evaluated the effects of prevalence on sensitivity and specificity using a bivariate random-effects model for each meta-analysis, with prevalence as a covariate. We estimated the overall effect of prevalence by pooling the effects using the inverse variance method. Within a given review, a change in prevalence from the lowest to highest value resulted in a corresponding change in sensitivity or specificity from 0 to 40 percentage points. This effect was statistically significant (p disease prevalence; there was no such systematic effect for sensitivity. The sensitivity and specificity of a test often vary with disease prevalence; this effect is likely to be the result of mechanisms, such as patient spectrum, that affect prevalence, sensitivity and specificity. Because it may be difficult to identify such mechanisms, clinicians should use prevalence as a guide when selecting studies that most closely match their situation.

  6. Broadband Liner Optimization for the Source Diagnostic Test Fan

    Science.gov (United States)

    Nark, Douglas M.; Jones, Michael G.

    2012-01-01

    The broadband component of fan noise has grown in relevance with the utilization of increased bypass ratio and advanced fan designs. Thus, while the attenuation of fan tones remains paramount, the ability to simultaneously reduce broadband fan noise levels has become more appealing. This paper describes a broadband acoustic liner optimization study for the scale model Source Diagnostic Test fan. Specifically, in-duct attenuation predictions with a statistical fan source model are used to obtain optimum impedance spectra over a number of flow conditions for three liner locations in the bypass duct. The predicted optimum impedance information is then used with acoustic liner modeling tools to design liners aimed at producing impedance spectra that most closely match the predicted optimum values. Design selection is based on an acceptance criterion that provides the ability to apply increased weighting to specific frequencies and/or operating conditions. Typical tonal liner designs targeting single frequencies at one operating condition are first produced to provide baseline performance information. These are followed by multiple broadband design approaches culminating in a broadband liner targeting the full range of frequencies and operating conditions. The broadband liner is found to satisfy the optimum impedance objectives much better than the tonal liner designs. In addition, the broadband liner is found to provide better attenuation than the tonal designs over the full range of frequencies and operating conditions considered. Thus, the current study successfully establishes a process for the initial design and evaluation of novel broadband liner concepts for complex engine configurations.

  7. A systematic review of the diagnostic performance of orthopedic physical examination tests of the hip.

    Science.gov (United States)

    Rahman, Labib Ataur; Adie, Sam; Naylor, Justine Maree; Mittal, Rajat; So, Sarah; Harris, Ian Andrew

    2013-08-30

    Previous reviews of the diagnostic performances of physical tests of the hip in orthopedics have drawn limited conclusions because of the low to moderate quality of primary studies published in the literature. This systematic review aims to build on these reviews by assessing a broad range of hip pathologies, and employing a more selective approach to the inclusion of studies in order to accurately gauge diagnostic performance for the purposes of making recommendations for clinical practice and future research. It specifically identifies tests which demonstrate strong and moderate diagnostic performance. A systematic search of Medline, Embase, Embase Classic and CINAHL was conducted to identify studies of hip tests. Our selection criteria included an analysis of internal and external validity. We reported diagnostic performance in terms of sensitivity, specificity, predictive values and likelihood ratios. Likelihood ratios were used to identify tests with strong and moderate diagnostic utility. Only a small proportion of tests reported in the literature have been assessed in methodologically valid primary studies. 16 studies were included in our review, producing 56 independent test-pathology combinations. Two tests demonstrated strong clinical utility, the patellar-pubic percussion test for excluding radiologically occult hip fractures (negative LR 0.05, 95% Confidence Interval [CI] 0.03-0.08) and the hip abduction sign for diagnosing sarcoglycanopathies in patients with known muscular dystrophies (positive LR 34.29, 95% CI 10.97-122.30). Fifteen tests demonstrated moderate diagnostic utility for diagnosing and/or excluding hip fractures, symptomatic osteoarthritis and loosening of components post-total hip arthroplasty. We have identified a number of tests demonstrating strong and moderate diagnostic performance. These findings must be viewed with caution as there are concerns over the methodological quality of the primary studies from which we have extracted our

  8. Diagnostic efficacy of in vitro methods vs. skin testing in patients with inhalant allergies

    International Nuclear Information System (INIS)

    Corey, J.P.; Liudahl, J.J.; Young, S.A.; Rodman, S.M.

    1991-01-01

    The purpose of our study was to investigate the diagnostic efficacy of two selected methods of in vitro allergy testing. Specifically, the PRIST/modified RAST I125 isotope systems and the Quantizyme/modified EAST alkaline phosphatase method were compared. The time, expense, convenience, and diagnostic efficacy of the two procedures are discussed. Special attention is given to the practicality of each method for the practicing physician

  9. Assessing Old and New Diagnostic Tests for Gastroesophageal Reflux Disease.

    Science.gov (United States)

    Vaezi, Michael F; Sifrim, Daniel

    2018-01-01

    A detailed critique of objective measurements of gastroesophageal reflux disease (GERD) would improve management of patients suspecting of having reflux, leading to rational selection of treatment and better outcomes. Many diagnostic tests for GERD have been developed over the past decades. We analyze their development, positive- and negative-predictive values, and ability to predict response to treatment. These features are important for development of medical, surgical, and endoscopic therapies for GERD. We discuss the value of available diagnostic tests and review their role in management of patients with persistent reflux symptoms despite adequate medical or surgical treatment. This is becoming a significant health economic problem, due to the widespread use of proton pump inhibitors. GERD is believed to cause nonesophageal symptoms, such as those provoked by ear, nose, throat, or respiratory disorders. We analyze the value of GERD diagnostic tests in evaluation of these troublesome, nonesophageal symptoms. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  10. Diagnostic development and support of MHD test facilities

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL) at Mississippi State University (MSU) is developing diagnostic instruments for MHD power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for Heat Recovery/Seed Recovery support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with DIAL's computers. Technical support for the diagnostic needs of the national MHD research effort is being provided. DIAL personnel will also cooperate with government agencies and private industries to improve the transformation of research and development results into processes, products and services applicable to their needs. 25 figs., 6 tabs.

  11. Diagnostic development and support of MHD test facilities

    International Nuclear Information System (INIS)

    Shepard, W.S.; Cook, R.L.

    1990-01-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL) at Mississippi State University (MSU) is developing diagnostic instruments for MHD power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for Heat Recovery/ Seed Recovery support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with DIAL's computers. Technical support for the diagnostic needs of the national MHD research effort is being provided. DIAL personnel will also cooperate with government agencies and private industries to improve the transformation of research and development results into processes, products and services applicable to their needs

  12. Evaluation of coproexamination as a diagnostic test for avian botulism

    Science.gov (United States)

    Jensen, Wayne I.

    1981-01-01

    Fecal extracts and blood sera from 113 ducks showing clinical signs of botulism were examined for Clostridium botulinum type C toxin by means of the mouse toxicity test to evaluate coproexamination as a diagnostic procedure, as compared with demonstration of toxin in serum. When death of test mice unprotected with type specific antitoxin (while protected controls survived) was the criterion, 78.8% of the sera and 5.3% of the fecal extracts were positive. When characteristic signs of intoxication in the unprotected mice was included as evidence of toxin in the specimens, these percentages increased to 86.7 and 6.2, respectively.Fecal specimens were collected hourly for the first 6 h after peroral dosing of eight mallards (Anas platyrhynchos) with 1.0 LD50, of type C toxin and at 24, 48, and 72 h from birds surviving that long. From 2 to 4 toxin-positive specimens were passed by all eight ducks during the first 6 h, five specimens were positive at 24 h, and three were positive at 48 h. Only three specimens were collected at 72 h, all of which were negative. These findings suggest that attempts to detect toxin in the feces of wild ducks might have been more successful had the birds been captured earlier in the course of the disease.

  13. [Critical reading of articles about diagnostic tests (part I): Are the results of the study valid?].

    Science.gov (United States)

    Arana, E

    2015-01-01

    In the era of evidence-based medicine, one of the most important skills a radiologist should have is the ability to analyze the diagnostic literature critically. This tutorial aims to present guidelines for determining whether primary diagnostic articles are valid for clinical practice. The following elements should be evaluated: whether the study can be applied to clinical practice, whether the technique was compared to the reference test, whether an appropriate spectrum of patients was included, whether expectation bias and verification bias were limited, the reproducibility of the study, the practical consequences of the study, the confidence intervals for the parameters analyzed, the normal range for continuous variables, and the placement of the test in the context of other diagnostic tests. We use elementary practical examples to illustrate how to select and interpret the literature on diagnostic imaging and specific references to provide more details. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  14. Mixed Portmanteau Test for Diagnostic Checking of Time Series Models

    Directory of Open Access Journals (Sweden)

    Sohail Chand

    2014-01-01

    Full Text Available Model criticism is an important stage of model building and thus goodness of fit tests provides a set of tools for diagnostic checking of the fitted model. Several tests are suggested in literature for diagnostic checking. These tests use autocorrelation or partial autocorrelation in the residuals to criticize the adequacy of fitted model. The main idea underlying these portmanteau tests is to identify if there is any dependence structure which is yet unexplained by the fitted model. In this paper, we suggest mixed portmanteau tests based on autocorrelation and partial autocorrelation functions of the residuals. We derived the asymptotic distribution of the mixture test and studied its size and power using Monte Carlo simulations.

  15. Drug sensitivity testing platforms for gastric cancer diagnostics.

    Science.gov (United States)

    Lau, Vianne; Wong, Andrea Li-Ann; Ng, Christopher; Mok, Yingting; Lakshmanan, Manikandan; Yan, Benedict

    2016-02-01

    Gastric cancer diagnostics has traditionally been histomorphological and primarily the domain of surgical pathologists. Although there is an increasing usage of molecular and genomic techniques for clinical diagnostics, there is an emerging field of personalised drug sensitivity testing. In this review, we describe the various personalised drug sensitivity testing platforms and discuss the challenges facing clinical adoption of these assays for gastric cancer. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Heritability of specific language impairment depends on diagnostic criteria.

    Science.gov (United States)

    Bishop, D V M; Hayiou-Thomas, M E

    2008-04-01

    Heritability estimates for specific language impairment (SLI) have been inconsistent. Four twin studies reported heritability of 0.5 or more, but a recent report from the Twins Early Development Study found negligible genetic influence in 4-year-olds. We considered whether the method of ascertainment influenced results and found substantially higher heritability if SLI was defined in terms of referral to speech and language pathology services than if defined by language test scores. Further analysis showed that presence of speech difficulties played a major role in determining whether a child had contact with services. Childhood language disorders that are identified by population screening are likely to have a different phenotype and different etiology from clinically referred cases. Genetic studies are more likely to find high heritability if they focus on cases who have speech difficulties and who have been referred for intervention.

  17. Background review for diagnostic test development for Zika virus infection.

    Science.gov (United States)

    Charrel, Rémi N; Leparc-Goffart, Isabelle; Pas, Suzan; de Lamballerie, Xavier; Koopmans, Marion; Reusken, Chantal

    2016-08-01

    To review the state of knowledge about diagnostic testing for Zika virus infection and identify areas of research needed to address the current gaps in knowledge. We made a non-systematic review of the published literature about Zika virus and supplemented this with information from commercial diagnostic test kits and personal communications with researchers in European preparedness networks. The review covered current knowledge about the geographical spread, pathogen characteristics, life cycle and infection kinetics of the virus. The available molecular and serological tests and biosafety issues are described and discussed in the context of the current outbreak strain. We identified the following areas of research to address current knowledge gaps: (i) an urgent assessment of the laboratory capacity and capability of countries to detect Zika virus; (ii) rapid and extensive field validation of the available molecular and serological tests in areas with and without Zika virus transmission, with a focus on pregnant women; (iii) monitoring the genomic diversity of circulating Zika virus strains; (iv) prospective studies into the virus infection kinetics, focusing on diagnostic sampling (specimen types, combinations and timings); and (v) developing external quality assessments for molecular and serological testing, including differential diagnosis for similar viruses and symptom clusters. The availability of reagents for diagnostic development (virus strains and antigens, quantified viral ribonucleic acid) needs to be facilitated. An international laboratory response is needed, including preparation of protocols for prospective studies to address the most pressing information needs.

  18. Screening for Wilson disease in acute liver failure: a comparison of currently available diagnostic tests

    DEFF Research Database (Denmark)

    Korman, J.D.; Volenberg, I.; Balko, J.

    2008-01-01

    a diagnostic sensitivity of 21% and specificity of 84% while, by nephelometry, a sensitivity of 56% and specificity of 63%. Serum copper levels exceeded 200 microg/dL in all ALF-WD patients measured (13/16), but were also elevated in non-WD ALF. An alkaline phosphatase (AP) to total bilirubin (TB) ratio ... and specificity of 100%. CONCLUSION: Conventional WD testing utilizing serum ceruloplasmin and/or serum copper levels are less sensitive and specific in identifying patients with ALF-WD than other available tests. More readily available laboratory tests including alkaline phosphatase, bilirubin and serum...

  19. Structured approach to design of diagnostic test evaluation studies for chronic progressive infections in animals

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils; Gardner, Ian Andrew

    2011-01-01

    Diagnostic test evaluations (DTEs) for chronic infections are challenging because a protracted incubation period has to be considered in the design of the DTE, and the adverse effects of infection may be widespread and progressive over an animal's entire life. Frequently, the specific purpose......) than originally intended. The objective of this paper is to outline a structured approach to the design and conduct of a DTE for diagnostic tests used for chronic infections in animals, and intended for different purposes. We describe the process from reflections about test purpose and the underlying...... of the test is not formally considered when a test is evaluated. Therefore, the result is often a DTE where test sensitivity and specificity estimates are biased, either because of problems with establishing the true infection status or because the test detects another aspect of the infection (and analyte...

  20. Optimal Combinations of Diagnostic Tests Based on AUC.

    Science.gov (United States)

    Huang, Xin; Qin, Gengsheng; Fang, Yixin

    2011-06-01

    When several diagnostic tests are available, one can combine them to achieve better diagnostic accuracy. This article considers the optimal linear combination that maximizes the area under the receiver operating characteristic curve (AUC); the estimates of the combination's coefficients can be obtained via a nonparametric procedure. However, for estimating the AUC associated with the estimated coefficients, the apparent estimation by re-substitution is too optimistic. To adjust for the upward bias, several methods are proposed. Among them the cross-validation approach is especially advocated, and an approximated cross-validation is developed to reduce the computational cost. Furthermore, these proposed methods can be applied for variable selection to select important diagnostic tests. The proposed methods are examined through simulation studies and applications to three real examples. © 2010, The International Biometric Society.

  1. Testing of Badminton-Specific Endurance.

    Science.gov (United States)

    Madsen, Christian M; Højlyng, Mads; Nybo, Lars

    2016-09-01

    Madsen, CM, Højlyng, M, and Nybo, L. Testing of badminton-specific endurance. J Strength Cond Res 30(9): 2582-2590, 2016-In the present study, a novel intermittent badminton endurance (B-ENDURANCE) test was developed and tested in elite (n = 17) and skilled (n = 9) badminton players and in age-matched physically active men (nonbadminton players; n = 8). In addition, B-ENDURANCE test-retest reproducibility was evaluated in 9 badminton players. The B-ENDURANCE test is an incremental test where each level consists of repeated sequences of badminton-specific actions toward the 4 corners of the court. The subject starts in the center of the court in front of a computer screen and within each sequence, he must, in a randomized order, complete 8 actions as dictated by the computer, providing the audiovisual input and verifying that the appropriate sensor is activated within the allocated time. Recovery time between each sequence is 10 seconds throughout the test, but the time to complete each sequence is gradually decreased until the subjects cannot follow the dictated tempo. The B-ENDURANCE test performance for elite players was better (p ≤ 0.05) compared with the skilled players and nonbadminton players. In addition, the B-ENDURANCE test performance correlated (r = 0.8 and p badminton-specific endurance but at least 1 familiarization trial is recommended if the test is used for evaluation of longitudinal changes, e.g., tracking training effects.

  2. NIF small optics laser damage test specifications

    International Nuclear Information System (INIS)

    Sheehan, L

    1999-01-01

    The Laser Damage Group is currently conducting tests on small optics samples supplied for initial evaluation of potential NIF suppliers. This document is meant to define the specification of laser-induced damage for small optics and the test methods used to collect the data. A rating system which will be applied for vendor selection is presented

  3. Comparative analysis of two rapid diagnostic tests for diagnosis of ...

    African Journals Online (AJOL)

    This study aims at comparing the diagnostic efficiencies of two commercially available kits for detecting Plasmodium falciparum infection in urine and blood of febrile patients for malaria diagnosis. This was an observational study in which matched blood and urine from symptomatic patients were tested for malaria using two ...

  4. Classification of chronic orofacial pain using an intravenous diagnostic test

    NARCIS (Netherlands)

    Tjakkes, G. -H. E.; De Bont, L. G. M.; van Wijhe, M.; Stegenga, B.

    The aim of this study was to evaluate the ability of a preliminary intravenous diagnostic test to classify chronic orofacial pain patients into different subgroups. Patients with chronic orofacial pain conditions that could not be unambiguously diagnosed. A retrospective evaluation of series of

  5. Assessment of the Diagnostic Potential of Clinotech TB Screen Test ...

    African Journals Online (AJOL)

    The Clinotech TB Screen test, a 3rd generation multi-antigen rapid chromatographic immunoassay for detection of IgG antibodies in serum against recombinant protein antigens 38kDa, 16kDa and 6kDa, was assessed for its diagnostic potential for diagnosis of active pulmonary TB in routine TB control programme in Abia ...

  6. Evaluation of microscopy and rapid diagnostic tests in screening ...

    African Journals Online (AJOL)

    Malaria is a life-threatening disease caused by the protozoa of the genus Plasmodium. Infection of individual is through the bites of infected female Anopheles mosquitoes. This study evaluated the performance of microscopy and rapid diagnostic tests (RDTs) in diagnosing malaria. A total of 400 clinically suspected malaria ...

  7. An audit of diagnostic tests performed in medical microbiology, and ...

    African Journals Online (AJOL)

    Clinical audit is an important tool for reviewing and improving the quality of service in clinical laboratories. This is a three year audit of diagnostic test carried out in Medical Microbiology and Immunology laboratories of University of Maiduguri Teaching Hospital, Maiduguri, Nigeria. The objectives were to document and ...

  8. Sensitivity and specificity of the amer dizziness diagnostic scale (adds) for patients with vestibular disorders.

    Science.gov (United States)

    Al Saif, Amer; Alsenany, Samira

    2015-01-01

    [Purpose] To investigate the sensitivity and specificity of a newly developed diagnostic tool, the Amer Dizziness Diagnostic Scale (ADDS), to evaluate and differentially diagnose vestibular disorder and to identify the strengths and weaknesses of the scale and its usefulness in clinical practice. [Subjects and Methods] Two hundred subjects of both genders (72 males, 128 females) aged between 18 to 60 (49.5±7.8) who had a history of vertigo and/or dizziness symptoms for this previous two weeks or less were recruited for the study. All subjects were referred by otolaryngologists, neurologists or family physicians in and around Jeddah, Kingdom of Saudi Arabia. On the first clinic visit, all the patients were evaluated once using the ADDS, following which they underwent routine testing of clinical signs and symptoms, audiometry, and a neurological examination, coupled with tests of Vestibulo-Ocular Reflex function, which often serves as the "gold standard" for determining the probability of a vestibular deficit. [Results] The results show that the ADDS strongly correlated with "true-positive" and "true-negative" responses for determining the probability of a vestibular disorder (r =0.95). A stepwise linear regression was conducted and the results indicate that the ADDS was a significant predictor of "true-positive" and "true-negative" responses in vestibular disorders (R(2) =0.90). Approximately 90% of the variability in the vestibular gold standard test was explained by its relationship to the ADDS. Moreover, the ADDS was found to have a sensitivity of 96% and a specificity of 96%. [Conclusion] This study showed that the Amer Dizziness Diagnostic Scale has high sensitivity and specificity and that it can be used as a method of differential diagnosis for patients with vestibular disorders.

  9. Development of a molecular diagnostic test for Retinitis Pigmentosa in the Japanese population.

    Science.gov (United States)

    Maeda, Akiko; Yoshida, Akiko; Kawai, Kanako; Arai, Yuki; Akiba, Ryutaro; Inaba, Akira; Takagi, Seiji; Fujiki, Ryoji; Hirami, Yasuhiko; Kurimoto, Yasuo; Ohara, Osamu; Takahashi, Masayo

    2018-05-21

    Retinitis Pigmentosa (RP) is the most common form of inherited retinal dystrophy caused by different genetic variants. More than 60 causative genes have been identified to date. The establishment of cost-effective molecular diagnostic tests with high sensitivity and specificity can be beneficial for patients and clinicians. Here, we developed a clinical diagnostic test for RP in the Japanese population. Evaluation of diagnostic technology, Prospective, Clinical and experimental study. A panel of 39 genes reported to cause RP in Japanese patients was established. Next generation sequence (NGS) technology was applied for the analyses of 94 probands with RP and RP-related diseases. After interpretation of detected genetic variants, molecular diagnosis based on a study of the genetic variants and a clinical phenotype was made by a multidisciplinary team including clinicians, researchers and genetic counselors. NGS analyses found 14,343 variants from 94 probands. Among them, 189 variants in 83 probands (88.3% of all cases) were selected as pathogenic variants and 64 probands (68.1%) have variants which can cause diseases. After the deliberation of these 64 cases, molecular diagnosis was made in 43 probands (45.7%). The final molecular diagnostic rate with the current system combining supplemental Sanger sequencing was 47.9% (45 of 94 cases). The RP panel provides the significant advantage of detecting genetic variants with a high molecular diagnostic rate. This type of race-specific high-throughput genotyping allows us to conduct a cost-effective and clinically useful genetic diagnostic test.

  10. Improving prescribing practices with rapid diagnostic tests (RDTs)

    DEFF Research Database (Denmark)

    Burchett, Helen E D; Leurent, Baptiste; Baiden, Frank

    2017-01-01

    OBJECTIVES: The overuse of antimalarial drugs is widespread. Effective methods to improve prescribing practice remain unclear. We evaluated the impact of 10 interventions that introduced rapid diagnostic tests for malaria (mRDTs) on the use of tests and adherence to results in different contexts...... packages, supervision, supplies and community sensitisation. OUTCOME MEASURES: Analysis explored variation in: (1) uptake of mRDTs (% febrile patients tested); (2) provider adherence to positive mRDTs (% Plasmodium falciparum positive prescribed/given Artemisinin Combination Treatment); (3) provider...... characteristics fitted with their own priorities. Goodness of fit of mRDTs with existing consultation and diagnostic practices appeared crucial to maximising the impact of mRDTs on care, as did prior familiarity with malaria testing; adequate human resources and supplies; possible alternative treatments for m...

  11. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India

    Directory of Open Access Journals (Sweden)

    Kiran Pote

    2018-01-01

    Full Text Available Background: Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. Methodology: The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. Results: We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15 than IgM IFA (sensitivity 96.8% and specificity 99.7% for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38% which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. Conclusion: IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  12. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India.

    Science.gov (United States)

    Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep

    2018-01-01

    Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  13. Can Emergency Medicine Residents Predict Cost of Diagnostic Testing?

    Directory of Open Access Journals (Sweden)

    Tainter, Christopher R

    2017-01-01

    Full Text Available Diagnostic testing represents a significant portion of healthcare spending, and cost should be considered when ordering such tests. Needless and excessive spending may occur without an appreciation of the impact on the larger healthcare system. Knowledge regarding the cost of diagnostic testing among emergency medicine (EM residents has not previously been studied. A survey was administered to 20 EM residents from a single ACGME-accredited three-year EM residency program, asking for an estimation of patient charges for 20 commonly ordered laboratory tests and seven radiological exams. We compared responses between residency classes to evaluate whether there was a difference based on level of training. The survey completion rate was 100% (20/20 residents. We noted significant discrepancies between the median resident estimates and actual charge to patient for both laboratory and radiological exams. Nearly all responses were an underestimate of the actual cost. The group median underestimation for laboratory testing was $114, for radiographs $57, and for computed tomography exams was $1,058. There was improvement in accuracy with increasing level of training. This pilot study demonstrates that EM residents have a poor understanding of the charges burdening patients and health insurance providers. In order to make balanced decisions with regard to diagnostic testing, providers must appreciate these factors. Education regarding the cost of providing emergency care is a potential area for improvement of EM residency curricula, and warrants further attention and investigation.

  14. Compare diagnostic tests using transformation-invariant smoothed ROC curves⋆

    Science.gov (United States)

    Tang, Liansheng; Du, Pang; Wu, Chengqing

    2012-01-01

    Receiver operating characteristic (ROC) curve, plotting true positive rates against false positive rates as threshold varies, is an important tool for evaluating biomarkers in diagnostic medicine studies. By definition, ROC curve is monotone increasing from 0 to 1 and is invariant to any monotone transformation of test results. And it is often a curve with certain level of smoothness when test results from the diseased and non-diseased subjects follow continuous distributions. Most existing ROC curve estimation methods do not guarantee all of these properties. One of the exceptions is Du and Tang (2009) which applies certain monotone spline regression procedure to empirical ROC estimates. However, their method does not consider the inherent correlations between empirical ROC estimates. This makes the derivation of the asymptotic properties very difficult. In this paper we propose a penalized weighted least square estimation method, which incorporates the covariance between empirical ROC estimates as a weight matrix. The resulting estimator satisfies all the aforementioned properties, and we show that it is also consistent. Then a resampling approach is used to extend our method for comparisons of two or more diagnostic tests. Our simulations show a significantly improved performance over the existing method, especially for steep ROC curves. We then apply the proposed method to a cancer diagnostic study that compares several newly developed diagnostic biomarkers to a traditional one. PMID:22639484

  15. Diagnostic development and support of MHD (magnetohydrodynamics) test facilities

    Energy Technology Data Exchange (ETDEWEB)

    1989-07-01

    Mississippi State University (MSU) is developing diagnostic instruments for Magnetohydrodynamics (MHD) power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for HRSR support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with MHD Energy Center computers. Technical support for the diagnostic needs of the national MHD research effort is being provided. MSU personnel will also cooperate with government agencies and private industries to improve the transformation of research and development results into processes, products and services applicable to their needs.

  16. Diagnostic accuracy of scapular physical examination tests for shoulder disorders: a systematic review.

    Science.gov (United States)

    Wright, Alexis A; Wassinger, Craig A; Frank, Mason; Michener, Lori A; Hegedus, Eric J

    2013-09-01

    To systematically review and critique the evidence regarding the diagnostic accuracy of physical examination tests for the scapula in patients with shoulder disorders. A systematic, computerised literature search of PubMED, EMBASE, CINAHL and the Cochrane Library databases (from database inception through January 2012) using keywords related to diagnostic accuracy of physical examination tests of the scapula. The Quality Assessment of Diagnostic Accuracy Studies tool was used to critique the quality of each paper. Eight articles met the inclusion criteria; three were considered to be of high quality. Of the three high-quality studies, two were in reference to a 'diagnosis' of shoulder pain. Only one high-quality article referenced specific shoulder pathology of acromioclavicular dislocation with reported sensitivity of 71% and 41% for the scapular dyskinesis and SICK scapula test, respectively. Overall, no physical examination test of the scapula was found to be useful in differentially diagnosing pathologies of the shoulder.

  17. The Hug-up Test: A New, Sensitive Diagnostic Test for Supraspinatus Tears

    Directory of Open Access Journals (Sweden)

    Yu-Lei Liu

    2016-01-01

    Full Text Available Background: The supraspinatus tendon is the most commonly affected tendon in rotator cuff tears. Early detection of a supraspinatus tear using an accurate physical examination is, therefore, important. However, the currently used physical tests for detecting supraspinatus tears are poor diagnostic indicators and involve a wide range of sensitivity and specificity values. Therefore, the aim of this study was to establish a new physical test for the diagnosis of supraspinatus tears and evaluate its accuracy in comparison with conventional tests. Methods: Between November 2012 and January 2014, 200 consecutive patients undergoing shoulder arthroscopy were prospectively evaluated preoperatively. The hug-up test, empty can (EC test, full can (FC test, Neer impingement sign, and Hawkins-Kennedy impingement sign were used and compared statistically for their accuracy in terms of supraspinatus tears, with arthroscopic findings as the gold standard. Muscle strength was precisely quantified using an electronic digital tensiometer. Results: The prevalence of supraspinatus tears was 76.5%. The hug-up test demonstrated the highest sensitivity (94.1%, with a low negative likelihood ratio (NLR, 0.08 and comparable specificity (76.6% compared with the other four tests. The area under the receiver operating characteristic curve for the hug-up test was 0.854, with no statistical difference compared with the EC test (z = 1.438, P = 0.075 or the FC test (z = 1.498, P = 0.067. The hug-up test showed no statistical difference in terms of detecting different tear patterns according to the position (χ2 = 0.578, P = 0.898 and size (Fisher′s exact test, P > 0.999 compared with the arthroscopic examination. The interobserver reproducibility of the hug-up test was high, with a kappa coefficient of 0.823. Conclusions: The hug-up test can accurately detect supraspinatus tears with a high sensitivity, comparable specificity, and low NLR compared with the conventional

  18. Aquifer test interpretation using derivative analysis and diagnostic plots

    Science.gov (United States)

    Hernández-Espriú, Antonio; Real-Rangel, Roberto; Cortés-Salazar, Iván; Castro-Herrera, Israel; Luna-Izazaga, Gabriela; Sánchez-León, Emilio

    2017-04-01

    Pumping tests remain a method of choice to deduce fundamental aquifer properties and to assess well condition. In the oil and gas (O&G) industry, well testing has been the core technique in examining reservoir behavior over the last 50 years. The pressure derivative by Bourdet, it is perhaps, the most significant single development in the history of well test analysis. Recently, the so-called diagnostics plots (e.g. drawdown and drawdown derivative in a log-log plot) have been successfully tested in aquifers. However, this procedure is still underutilized by groundwater professionals. This research illustrates the applicability range, advantages and drawbacks (e.g. smoothing procedures) of diagnostic plots using field examples from a wide spectrum of tests (short/long tests, constant/variable flow rates, drawdown/buildup stages, pumping well/observation well) in dissimilar geological conditions. We analyze new and pre-existent aquifer tests in Mexico, USA, Canada, Germany, France and Saudi Arabia. In constant flow rate tests, our results show that derivative analysis is an easy, robust and powerful tool to assess near-borehole damage effects, formation heterogeneity, boundaries, flow regimes, infinite-acting radial stages, i.e., valid Theisian framework, and fracture-driven flow. In step tests, the effectiveness relies on high-frequency drawdown measurements. Moreover, we adapt O&G analytical solutions to cater for the conditions in groundwater systems. In this context, further parameters can be computed analytically from the plots, such as skin factor, head losses, wellbore storage, distance to the boundary, channel-aquifer and/or fracture zone width, among others. Therefore, diagnostic plots should be considered a mandatory tool for pumping tests analysis among hydrogeologists. This project has been supported by DGAPA (UNAM) under the research project PAPIIT IN-112815.

  19. Surface-specific additive manufacturing test artefacts

    Science.gov (United States)

    Townsend, Andrew; Racasan, Radu; Blunt, Liam

    2018-06-01

    Many test artefact designs have been proposed for use with additive manufacturing (AM) systems. These test artefacts have primarily been designed for the evaluation of AM form and dimensional performance. A series of surface-specific measurement test artefacts designed for use in the verification of AM manufacturing processes are proposed here. Surface-specific test artefacts can be made more compact because they do not require the large dimensions needed for accurate dimensional and form measurements. The series of three test artefacts are designed to provide comprehensive information pertaining to the manufactured surface. Measurement possibilities include deviation analysis, surface texture parameter data generation, sub-surface analysis, layer step analysis and build resolution comparison. The test artefacts are designed to provide easy access for measurement using conventional surface measurement techniques, for example, focus variation microscopy, stylus profilometry, confocal microscopy and scanning electron microscopy. Additionally, the test artefacts may be simply visually inspected as a comparative tool, giving a fast indication of process variation between builds. The three test artefacts are small enough to be included in every build and include built-in manufacturing traceability information, making them a convenient physical record of the build.

  20. The dilemma of diagnostic testing for Prader-Willi syndrome

    Science.gov (United States)

    Hung, Dorothy

    2017-01-01

    Although Prader-Willi syndrome (PWS) is a well-described clinical dysmorphic syndrome, DNA testing is required for a definitive diagnosis. A definitive diagnosis can be made in approximately 99% of cases using DNA testing; there are a number of DNA tests that can be used for this purpose, although there is no set standard algorithm of testing. The dilemma arises because of the complex genetic mechanisms at the basis of PWS, which need to be elucidated. To establish the molecular mechanism with a complete work up, involves at least 2 tests. Here we discuss the commonly used tests currently available and suggest a cost—effective approach to diagnostic testing. PMID:28164030

  1. Beyond the 2×2 -contingency table: a primer on entropies and mutual information in various scenarios involving m diagnostic categories and n categories of diagnostic tests.

    Science.gov (United States)

    Reibnegger, Gilbert

    2013-10-21

    Usual evaluation tools for diagnostic tests such as, sensitivity/specificity and ROC analyses, are designed for the discrimination between two diagnostic categories, using dichotomous test results. Information theoretical quantities such as mutual information allow in depth-analysis of more complex discrimination problems, including continuous test results, but are rarely used in clinical chemistry. This paper provides a primer on useful information theoretical concepts with a strong focus on typical diagnostic scenarios. Information theoretical concepts are shortly explained. Mathematica CDF documents are provided which compute entropies and mutual information as function of pretest probabilities and the distribution of test results among the categories, and allow interactive exploration of the behavior of these quantities in comparison with more conventional diagnostic measures. Using data from a previously published study, the application of information theory to practical diagnostic problems involving up to 4×4 -contingency tables is demonstrated. Information theoretical concepts are particularly useful for diagnostic problems requiring more than the usual binary classification. Quantitative test results can be properly analyzed, and in contrast to popular concepts such as ROC analysis, the effects of variations of pre-test probabilities of the diagnostic categories can be explicitly taken into account. © 2013 Elsevier B.V. All rights reserved.

  2. Genetic test utilization and diagnostic yield in adult patients with neurological disorders.

    Science.gov (United States)

    Bardakjian, Tanya M; Helbig, Ingo; Quinn, Colin; Elman, Lauren B; McCluskey, Leo F; Scherer, Steven S; Gonzalez-Alegre, Pedro

    2018-03-28

    To determine the diagnostic yield of different genetic test modalities in adult patients with neurological disorders, we evaluated all adult patients seen for genetic diagnostic evaluation in the outpatient neurology practice at the University of Pennsylvania between January 2016 and April 2017 as part of the newly created Penn Neurogenetics Program. Subjects were identified through our electronic medical system as those evaluated by the Program's single clinical genetic counselor in that period. A total of 377 patients were evaluated by the Penn Neurogenetics Program in different settings and genetic testing recommended. Of those, 182 (48%) were seen in subspecialty clinic setting and 195 (52%) in a General Neurogenetics Clinic. Genetic testing was completed in over 80% of patients in whom it was recommended. The diagnostic yield was 32% across disease groups. Stratified by testing modality, the yield was highest with directed testing (50%) and array comparative genomic hybridization (45%), followed by gene panels and exome testing (25% each). In conclusion, genetic testing can be successfully requested in clinic in a large majority of adult patients. Age is not a limiting factor for a genetic diagnostic evaluation and the yield of clinical testing across phenotypes (almost 30%) is consistent with previous phenotype-focused or research-based studies. These results should inform the development of specific guidelines for clinical testing and serve as evidence to improve reimbursement by insurance payers.

  3. Diagnostic Accuracy of the Slump Test for Identifying Neuropathic Pain in the Lower Limb.

    Science.gov (United States)

    Urban, Lawrence M; MacNeil, Brian J

    2015-08-01

    Diagnostic accuracy study with nonconsecutive enrollment. To assess the diagnostic accuracy of the slump test for neuropathic pain (NeP) in those with low to moderate levels of chronic low back pain (LBP), and to determine whether accuracy of the slump test improves by adding anatomical or qualitative pain descriptors. Neuropathic pain has been linked with poor outcomes, likely due to inadequate diagnosis, which precludes treatment specific for NeP. Current diagnostic approaches are time consuming or lack accuracy. A convenience sample of 21 individuals with LBP, with or without radiating leg pain, was recruited. A standardized neurosensory examination was used to determine the reference diagnosis for NeP. Afterward, the slump test was administered to all participants. Reports of pain location and quality produced during the slump test were recorded. The neurosensory examination designated 11 of the 21 participants with LBP/sciatica as having NeP. The slump test displayed high sensitivity (0.91), moderate specificity (0.70), a positive likelihood ratio of 3.03, and a negative likelihood ratio of 0.13. Adding the criterion of pain below the knee significantly increased specificity to 1.00 (positive likelihood ratio = 11.9). Pain-quality descriptors did not improve diagnostic accuracy. The slump test was highly sensitive in identifying NeP within the study sample. Adding a pain-location criterion improved specificity. Combining the diagnostic outcomes was very effective in identifying all those without NeP and half of those with NeP. Limitations arising from the small and narrow spectrum of participants with LBP/sciatica sampled within the study prevent application of the findings to a wider population. Diagnosis, level 4-.

  4. The impact of new trends in POCTs for companion diagnostics, non-invasive testing and molecular diagnostics.

    Science.gov (United States)

    Huckle, David

    2015-06-01

    Point-of-care diagnostics have been slowly developing over several decades and have taken on a new importance in current healthcare delivery for both diagnostics and development of new drugs. Molecular diagnostics have become a key driver of technology change and opened up new areas in companion diagnostics for use alongside pharmaceuticals and in new clinical approaches such as non-invasive testing. Future areas involving smartphone and other information technology advances, together with new developments in molecular biology, microfluidics and surface chemistry are adding to advances in the market. The focus for point-of-care tests with molecular diagnostic technologies is focused on advancing effective applications.

  5. Convergent and diagnostic validity of STAVUX, a word and pseudoword spelling test for adults.

    Science.gov (United States)

    Östberg, Per; Backlund, Charlotte; Lindström, Emma

    2016-10-01

    Few comprehensive spelling tests are available in Swedish, and none have been validated in adults with reading and writing disorders. The recently developed STAVUX test includes word and pseudoword spelling subtests with high internal consistency and adult norms stratified by education. This study evaluated the convergent and diagnostic validity of STAVUX in adults with dyslexia. Forty-six adults, 23 with dyslexia and 23 controls, took STAVUX together with a standard word-decoding test and a self-rated measure of spelling skills. STAVUX subtest scores showed moderate to strong correlations with word-decoding scores and predicted self-rated spelling skills. Word and pseudoword subtest scores both predicted dyslexia status. Receiver-operating characteristic (ROC) analysis showed excellent diagnostic discriminability. Sensitivity was 91% and specificity 96%. In conclusion, the results of this study support the convergent and diagnostic validity of STAVUX.

  6. A Highly Sensitive Rapid Diagnostic Test for Chagas Disease That Utilizes a Recombinant Trypanosoma cruzi Antigen

    Science.gov (United States)

    Barfield, C. A.; Barney, R. S.; Crudder, C. H.; Wilmoth, J. L.; Stevens, D. S.; Mora-Garcia, S.; Yanovsky, M. J.; Weigl, B. H.; Yanovsky, J.

    2011-01-01

    Improved diagnostic tests for Chagas disease are urgently needed. A new lateral flow rapid test for Chagas disease is under development at PATH, in collaboration with Laboratorio Lemos of Argentina, which utilizes a recombinant antigen for detection of antibodies to Trypanosoma cruzi. To evaluate the performance of this test, 375 earlier characterized serum specimens from a region where Chagas is endemic were tested using a reference test (the Ortho T. cruzi ELISA, Johnson & Johnson), a commercially available rapid test (Chagas STAT-PAK, Chembio), and the PATH–Lemos rapid test. Compared to the composite reference tests, the PATH–Lemos rapid test demonstrated an optimal sensitivity of 99.5% and specificity of 96.8%, while the Chagas STAT-PAK demonstrated a sensitivity of 95.3% and specificity of 99.5%. These results indicate that the PATH–Lemos rapid test shows promise as an improved and reliable tool for screening and diagnosis of Chagas disease. PMID:21342808

  7. The indication area of a diagnostic test. Part I--discounting gain and loss in diagnostic certainty

    NARCIS (Netherlands)

    Stalpers, Lukas J. A.; Nelemans, Patty J.; Geurts, Sandra M. E.; Jansen, Erik; de Boer, Peter; Verbeek, André L. M.

    2015-01-01

    Test performance is conventionally expressed by gain in diagnostic certainty. We propose net diagnostic gain and indication area as more appropriate measures of test performance; then, the loss in certainty due to misclassification and the information of "no test" would be performed are taken into

  8. [Pathogenic Mechanism and Diagnostic Testing for Drug Allergies].

    Science.gov (United States)

    Uno, Katsuji

    2018-01-01

     Three stages of the pathogenic mechanism of drug allergies can be considered: antigen formation, immune reaction and inflammation/disorder reaction. Drugs are thought to form 4 types of antigens: drug only, polymers, drug-carrier conjugates, and metabolite-carrier complexes. Antigens are recognized by B cell receptors and T cell receptors. Helper T cells (Th) are differentiated into four subsets, namely, Th1, Th2, Th17 and regulatory T cells (Treg). Th1 produces interleukin (IL)-2 and interferon (IFN)-γ, and activates macrophages and cytotoxic T cells (Tc). Macrophages induce type IV allergies, and Tc lead to serious type IV allergies. On the other hand, Th2 produces IL-4, IL-5, and IL-6, etc., and activates B cells. B cells produce IgE antibodies, and the IgE antibody affects mast cells and induces type I allergies. Activated eosinophil leads to the chronic state of type I allergy. Diagnostic testing for allergenic drugs is necessary for patients with drug allergies. Because in vivo diagnostic tests for allergenic drugs are associated with a risk and burden to the patient, in vitro allergy tests are recommended to identify allergenic drugs. In allergy tests performed in vitro, cytological tests are more effective than serological tests, and the leukocyte migration test (LMT) presently has the highest efficacy. An LMT-chamber is better than LMT-agarose in terms of usability and sensitivity, and it can detect about 80% of allergenic drugs.

  9. A Review of Neuropathic Pain: From Diagnostic Tests to Mechanisms

    OpenAIRE

    Truini, Andrea

    2017-01-01

    Neuropathic pain develops when the somatosensory nervous system is affected by a lesion or disease. Diagnostic tests aimed at assessing somatosensory afferent pathway damage are therefore useful for diagnosing neuropathic pain. Neuropathic pain manifests with a range of different symptoms such as ongoing burning pain, squeezing or pressure pain, paroxysmal electric shock-like sensations, stabbing pain, or mechanical dynamic allodynia. The various types of neuropathic pain are associated with ...

  10. Diagnostic accuracy of physical examination tests of the ankle/foot complex: a systematic review.

    Science.gov (United States)

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren; Cook, Chad

    2013-08-01

    Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. 3a.

  11. A general diagnostic model applied to language testing data.

    Science.gov (United States)

    von Davier, Matthias

    2008-11-01

    Probabilistic models with one or more latent variables are designed to report on a corresponding number of skills or cognitive attributes. Multidimensional skill profiles offer additional information beyond what a single test score can provide, if the reported skills can be identified and distinguished reliably. Many recent approaches to skill profile models are limited to dichotomous data and have made use of computationally intensive estimation methods such as Markov chain Monte Carlo, since standard maximum likelihood (ML) estimation techniques were deemed infeasible. This paper presents a general diagnostic model (GDM) that can be estimated with standard ML techniques and applies to polytomous response variables as well as to skills with two or more proficiency levels. The paper uses one member of a larger class of diagnostic models, a compensatory diagnostic model for dichotomous and partial credit data. Many well-known models, such as univariate and multivariate versions of the Rasch model and the two-parameter logistic item response theory model, the generalized partial credit model, as well as a variety of skill profile models, are special cases of this GDM. In addition to an introduction to this model, the paper presents a parameter recovery study using simulated data and an application to real data from the field test for TOEFL Internet-based testing.

  12. The diagnostic accuracy of three rapid diagnostic tests for typhoid fever at Chittagong Medical College Hospital, Chittagong, Bangladesh.

    Science.gov (United States)

    Maude, Rapeephan R; de Jong, Hanna K; Wijedoru, Lalith; Fukushima, Masako; Ghose, Aniruddha; Samad, Rasheda; Hossain, Mohammed Amir; Karim, Mohammed Rezaul; Faiz, Mohammed Abul; Parry, Christopher M

    2015-10-01

    To determine the diagnostic accuracy of three rapid diagnostic tests (RDTs) for typhoid fever in febrile hospitalised patients in Bangladesh. Febrile adults and children admitted to Chittagong Medical College Hospital, Bangladesh, were investigated with Bact/Alert(®) blood cultures and real-time PCR to detect Salmonella enterica Typhi and Paratyphi A and assays for Rickettsia, leptospirosis and dengue fever. Acute serum samples were examined with the LifeAssay (LA) Test-it™ Typhoid IgM lateral flow assay detecting IgM antibodies against S. Typhi O antigen, CTKBiotech Onsite Typhoid IgG/IgM Combo Rapid-test cassette lateral flow assay detecting IgG and IgM antibodies against S. Typhi O and H antigens and SD Bioline line assay for IgG and IgM antibodies against S. Typhi proteins. In 300 malaria smear-negative febrile patients [median (IQR) age of 13.5 (5-31) years], 34 (11.3%) had confirmed typhoid fever: 19 positive by blood culture for S. Typhi (three blood PCR positive) and 15 blood culture negative but PCR positive for S. Typhi in blood. The respective sensitivity and specificity of the three RDTs in patients using a composite reference standard of blood culture and/or PCR-confirmed typhoid fever were 59% and 61% for LifeAssay, 59% and 74% for the CTK IgM and/or IgG, and 24% and 96% for the SD Bioline RDT IgM and/or IgG. The LifeAssay RDT had a sensitivity of 63% and a specificity of 91% when modified with a positive cut-off of ≥2+ and analysed using a Bayesian latent class model. These typhoid RDTs demonstrated moderate diagnostic accuracies, and better tests are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  13. Sensitive KIT D816V mutation analysis of blood as a diagnostic test in mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, Hanne; Bindslev-Jensen, Carsten

    2014-01-01

    The recent progress in sensitive KIT D816V mutation analysis suggests that mutation analysis of peripheral blood (PB) represents a promising diagnostic test in mastocytosis. However, there is a need for systematic assessment of the analytical sensitivity and specificity of the approach in order...... to establish its value in clinical use. We therefore evaluated sensitive KIT D816V mutation analysis of PB as a diagnostic test in an entire case-series of adults with mastocytosis. We demonstrate for the first time that by using a sufficiently sensitive KIT D816V mutation analysis, it is possible to detect...... the mutation in PB in nearly all adult mastocytosis patients. The mutation was detected in PB in 78 of 83 systemic mastocytosis (94%) and 3 of 4 cutaneous mastocytosis patients (75%). The test was 100% specific as determined by analysis of clinically relevant control patients who all tested negative. Mutation...

  14. Standard specification for agencies performing nondestructive testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This specification covers minimum requirements for agencies performing nondestructive testing (NDT). 1.2 When using this specification to assess the capability of, or to accredit NDT agencies, Guide E 1359 shall be used as a basis for the survey. It can be supplemented as necessary with more detail in order to meet the auditor's specific needs. 1.3 This specification can be used as a basis to evaluate testing or inspection agencies, or both, and is intended for use for the qualifying or accrediting, or both, of testing or inspection agencies, public or private. 1.4 The use of SI or inch-pound units, or combination thereof, will be the responsibility of the technical committee whose standards are referred to in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to...

  15. An evaluation of a diagnostic test to identify the sex of farmed rainbow trout, using sex-specific molecular markers Evaluación de un test diagnóstico para identificar el sexo en truchas arcoíris por medio de marcadores moleculares específicos

    Directory of Open Access Journals (Sweden)

    María E López

    2012-11-01

    Full Text Available In trout farming males exhibits lower growth rate and precocious sexual maturation in contrast to females. Since these traits are detrimental for intensive production, all females populations are most appreciated by fish farmers. Molecular markers sex-specific have been developed for rainbow trout that can be useful to diagnose the phenotypic sex of individuals. We evaluated the use of two SCAR markers (OmyP9 & Omy163, which show polymorphisms between males and females in rainbow trout as a diagnostic test for sexing farmed trout. Adult trout (n = 131 were genotyped to assess the association of the SCAR markers with phenotypic sex. To evaluate the correct performance of the SCAR marker in sex diagnosis, each marker and both were analyzed to estimate its specificity (the proportion of males that are correctly identified, sensitivity (the proportion of females that are correctly identified and predictive value (the probability of the correct positive or negative female identification. Significant associations with phenotypic sex of both SCAR markers with sex were found. The sensitivity and predictive (positive and negative indexes show higher values when both SCAR markers were considered (95.7, 77.4 and 94.4%, respectively. For joined SCAR markers a likelihood ratio (LR+ of 3.43 was obtained indicating its utility to establish a diagnostic test for sexing trout by use of marker-based analysis.En el cultivo de truchas los individuos del sexo masculino presentan menor tasa de crecimiento y maduración sexual precoz, características que no presentan las hembras. Debido a estos rasgos indeseables para el cultivo intensivo, el uso de poblaciones todo hembra es una práctica habitual en el cultivo de truchas. Para trucha arcoíris se han desarrollado marcadores moleculares sexo específico que pueden utilizarse en el diagnóstico temprano del sexo, en condiciones de cultivo. Se evaluó la aplicación de dos marcadores SCAR (OmyP9 y Omy163, que muestran

  16. [New Radiopharmaceuticals Based on Prostate-Specific Inhibitors of Membrane Antigen for Diagnostics and Therapy of Metastatic Prostate Cancer].

    Science.gov (United States)

    Vlasova, O P; German, K E; Krilov, V V; Petriev, V M; Epstein, N B

    2015-01-01

    About 10.7% cases of prostate cancer were registered in Russia in 2011 (40,000 patients). More than half of cancer cases were revealed in advanced (III-IV) stages when metastases inevitably developed quickly. Clinical problem of early diagnostics and treatment of metastatic prostate cancer is still not solved. Anatomical imaging techniques have low sensitivity and specificity for the detection of this disease. Metabolic visualization methods which use prostate specific antigen (PSA) as a marker are also ineffective. This article describes prostate-specific membrane antigens (PSMA) that are proposed as a marker for diagnostics and therapy of prostate cancer. The most promising PSMA-based radiopharmaceutical agent for diagnostics has been developed and clinically tested in the European countries. These pharmaceuticals are based on small peptide molecules modified with urea, and have the highest affinity to PSMA. Favorable phannacokinetics, rapid accumulation in the tumor and rapid excretion from the body are beneficial features of these pharmaceuticals.

  17. [Stress-ECG is adequate to detect myocardial ischemia: when are additional diagnostic tests needed?].

    Science.gov (United States)

    Baer, F M

    2007-09-01

    The stress-ECG is the most often adopted and most cost effective initial diagnostic test for the assessment of myocardial ischemia in patients with suspected coronary artery disease (CAD). Prerequisites for the diagnostic usefullness of stress-ECG are a clearly interpretable ST-segment, ability to reach the predicted work load, an intermediate pretest probability for CAD ranging between 10% and 90% and the absence of any contraindications for dynamic exercise. Because of the limited diagnostic sensitivity of about 70%, and a high percentage of patients, who are unable to exercise, a negative stress ECG can definitely not exclude hemodynamically significant CAD. Therefore, stress imaging techniques like myocardial scintigraphy, stress-echocardiography and stress magnetic resonance imaging play a major role in the stepwise diagnostic work-up of patients with suspected CAD. These stress imaging techniques are basically interchangeable since no method is definitely superior to one of the others. However, each method has its specific pros and cons and inherent contraindications. Therefore the choice of the stress imaging method and the form of stress applied should be based on the individual patients characteristics to gain optimal image quality and diagnostic accuracy. Moreover, the decision for one method should take the local availability and institutional expertise of diagnostic centers into account. Although partly substituted by stress imaging techniques the stress-ECG still remains the workhorse for a stepwise diagnostic work-up of patients with suspected CAD.

  18. LeRC rail accelerators: test designs and diagnostic techniques

    International Nuclear Information System (INIS)

    Zana, L.M.; Kerslake, W.R.; Sturman, J.C.; Wang, S.Y.; Terdan, F.F.

    1984-01-01

    The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed. 15 references

  19. Developing and Standardization of a Diagnostic Reading Test

    Directory of Open Access Journals (Sweden)

    Tahereh Sima-Shirazi

    2004-06-01

    Full Text Available Objective: This paper is a report on the development, structure and content of a diagnostic dyslexia reading test. The target population of this test is persian children who have problems in learning reading and may be considered as dyslexic. This diagnostic test is the first reading test developed for the native speakers of persian. Materials & Methods: The theoretical framework of the test is based on two well- established reading tests for the English speaking children, namely Durrell Analysis of Reading and Neale Analysis of Reading Ability. The linguistic content of the subtests is selected from the vocabulary and texts of the textbook used in the primary schools. Both the vocabulary and the sentences of the parrallel passeges were controlled for frequency, phonemic/graphemic regularity, syllable structure, morphology, syntax and semantics. They were also controlled for value judgement by two linguistics and three first grader teachers.The first version of the test is normed on 605 boy and girl first graders from different educational sectors and schools selected randomly.The method used in this research is cross- sectional, descriptive- analytic and the data analysis is based on pearson, and mann-whitney u. Results: Reliability of the test is calculated based on parrallel forms (~ 90% and validity is based on content validity.This test has a supplementary section including spelling, graphem/ phoneme correspondness, nonword reading, irregular word reading, and copy subtests. Conclusion: Considering highreliability and precise validation of the test it can be used to diagnose the dyslexia and related linguistic impairments.

  20. Cost-effectiveness of using a molecular diagnostic test to improve preoperative diagnosis of thyroid cancer.

    Science.gov (United States)

    Najafzadeh, Mehdi; Marra, Carlo A; Lynd, Larry D; Wiseman, Sam M

    2012-12-01

    Fine-needle aspiration biopsy (FNAB) is a safe and inexpensive diagnostic procedure for evaluating thyroid nodules.Up to 25% of the results from an FNAB, however, may not be diagnostic or may be indeterminate, leading to a subsequent diagnostic thyroid surgery. A new molecularly based diagnostic test could potentially reduce indeterminate cytological results and, with high accuracy, provide a definitive diagnosis for cancer in thyroid nodules. The aim of the study was to estimate the cost-effectiveness of utilizing a molecular diagnostic (DX) test as an adjunct to FNAB, compared with NoDX, to improve the preoperative diagnosis of thyroid nodules. We constructed a patient-level simulation model to estimate the clinical and economic outcomes of using a DX test compared with current practice (NoDX) for the diagnosis of thyroid nodules. By using a cost-effectiveness framework, we measured incremental clinical benefits in terms of quality-adjusted life-years and incremental costs over a 10-year time horizon. Assuming 95% sensitivity and specificity of the Dx test when used as an adjunct to FNAB, the utilization of the DX test resulted in a gain of 0.046 quality-adjusted life-years (95% confidence interval 0.019-0.078) and a saving of $1087 (95% confidence interval $691-$1533) in direct costs per patient. If the cost of the Dx test is less than $1087 per test, we expect to save quality-adjusted life-years and reduce costs when it is utilized. Sensitivity of the DX test, compared with specificity, had a larger influence on the overall outcomes. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  1. Tests in Print II: An Index to Tests, Test Reviews, and the Literature on Specific Tests.

    Science.gov (United States)

    Buros, Oscar K., Ed.

    Tests in Print II is a comprehensive, annotated bibliography of all in-print tests published as separates for use with English-speaking subjects. The 1,155 two-column pages list 2,467 tests in print as of early 1974; 16,574 references through 1971 on specific tests; a reprinting of the 1974 APA-AERA-NCME Standards for Educational andPsychological…

  2. 30 CFR 250.522 - When do I have to repeat casing diagnostic testing?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When do I have to repeat casing diagnostic... Operations Casing Pressure Management § 250.522 When do I have to repeat casing diagnostic testing? Casing diagnostic testing must be repeated according to the following table: When * * * you must repeat diagnostic...

  3. Integrated Rapid-Diagnostic-Test Reader Platform on a Cellphone

    Science.gov (United States)

    Mudanyali, Onur; Dimitrov, Stoyan; Sikora, Uzair; Padmanabhan, Swati; Navruz, Isa; Ozcan, Aydogan

    2012-01-01

    We demonstrate a cellphone based Rapid-Diagnostic-Test (RDT) reader platform that can work with various lateral flow immuno-chromatographic assays and similar tests to sense the presence of a target analyte in a sample. This compact and cost-effective digital RDT reader, weighing only ~65 grams, mechanically attaches to the existing camera unit of a cellphone, where various types of RDTs can be inserted to be imaged in reflection or transmission modes under light-emitting-diode (LED) based illumination. Captured raw images of these tests are then digitally processed (within less than 0.2 sec/image) through a smart application running on the cellphone for validation of the RDT as well as for automated reading of its diagnostic result. The same smart application running on the cellphone then transmits the resulting data, together with the RDT images and other related information (e.g., demographic data) to a central server, which presents the diagnostic results on a world-map through geo-tagging. This dynamic spatio-temporal map of various RDT results can then be viewed and shared using internet browsers or through the same cellphone application. We tested this platform using malaria, tuberculosis (TB) as well as HIV RDTs by installing it on both Android based smart-phones as well as an iPhone. Providing real-time spatio-temporal statistics for the prevalence of various infectious diseases, this smart RDT reader platform running on cellphones might assist health-care professionals and policy makers to track emerging epidemics worldwide and help epidemic preparedness. PMID:22596243

  4. Diagnostic Air Quality Model Evaluation of Source-Specific Primary and Secondary Fine Particulate Carbon

    Science.gov (United States)

    Ambient measurements of 78 source-specific tracers of primary and secondary carbonaceous fine particulate matter collected at four midwestern United States locations over a full year (March 2004–February 2005) provided an unprecedented opportunity to diagnostically evaluate...

  5. A web-based test of residents' skills in diagnostic radiology

    International Nuclear Information System (INIS)

    Finlay, K.; Norman, G.R.; Keane, D.R.; Stolberg, H.

    2006-01-01

    To develop an objective, Web-based tool for evaluating residents' knowledge of diagnostic radiology. We developed and tested a Web-based evaluation tool (the Diagnostic Radiology Skills Test) that consists of 3 tests, one in each of 3 domains of diagnostic radiology: chest, gastrointestinal, and musculoskeletal imaging. Each test comprises 30 cases representing a range of difficulty in the domain, including normal states, normal variants, typical cases of common diagnoses, and cases with more subtle findings. Cases are presented with a long menu of domain-specific possible diagnoses (response options), each coded for diagnostic appropriateness. Our subjects were 21 residents in postgraduate year (PGY) 2 to 5 and 11 experts in diagnostic radiology. Subjects accessed the tool via a Web site on our Web server. Residents test results were compared for reliability and validity across domain, case, and training level. In addition, results were correlated with commonly used established and objective evaluation tools. The tool demonstrated consistent monotonic improvement in performance with training level. It showed acceptable reliability in discriminating between residents at different performance levels, both within and across training levels (r = 0.53 within level and 0.69 across levels). Test results also had concurrent validity against the American College of Radiology In-Training Examination, a widely accepted objective assessment tool (r = 0.65, P < 0.01), and 2 Objective Structured Clinical Examinations (OSCEs) focusing on diagnostic skills (r = 0.78 and r 0.69, P < 0.01, respectively). Our study demonstrates the feasibility of a Web-based, standardized, objective assessment method for evaluating residents' performance. (author)

  6. Get the Diagnosis: an evidence-based medicine collaborative Wiki for diagnostic test accuracy.

    Science.gov (United States)

    Hammer, Mark M; Kohlberg, Gavriel D

    2017-04-01

    Despite widespread calls for its use, there are challenges to the implementation of evidence-based medicine (EBM) in clinical practice. In response to the challenges of finding timely, pertinent information on diagnostic test accuracy, we developed an online, crowd-sourced Wiki on diagnostic test accuracy called Get the Diagnosis (GTD, http://www.getthediagnosis.org). Since its launch in November 2008 till October 2015, GTD has accumulated information on 300 diagnoses, with 1617 total diagnostic entries. There are a total of 1097 unique diagnostic tests with a mean of 5.4 tests (range 0-38) per diagnosis. 73% of entries (1182 of 1617) have an associated sensitivity and specificity and 89% of entries (1432 of 1617) have associated peer-reviewed literature citations. Altogether, GTD contains 474 unique literature citations. For a sample of three diagnoses, the search precision (percentage of relevant results in the first 30 entries) in GTD was 100% as compared with a range of 13.3%-63.3% for PubMed and between 6.7% and 76.7% for Google Scholar. GTD offers a fast, precise and efficient way to look up diagnostic test accuracy. On three selected examples, GTD had a greater precision rate compared with PubMed and Google Scholar in identifying diagnostic test information. GTD is a free resource that complements other currently available resources. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. DiagTest3Grp: An R Package for Analyzing Diagnostic Tests with Three Ordinal Groups

    Directory of Open Access Journals (Sweden)

    Jingqin Luo

    2012-10-01

    Full Text Available Medical researchers endeavor to identify potentially useful biomarkers to develop marker-based screening assays for disease diagnosis and prevention. Useful summary measures which properly evaluate the discriminative ability of diagnostic markers are critical for this purpose. Literature and existing software, for example, R packages nicely cover summary measures for diagnostic markers used for the binary case (e.g., healthy vs. diseased. An intermediate population at an early disease stage usually exists between the healthy and the fully diseased population in many disease processes. Supporting utilities for three-group diagnostic tests are highly desired and important for identifying patients at the early disease stage for timely treatments. However, application packages which provide summary measures for three ordinal groups are currently lacking. This paper focuses on two summary measures of diagnostic accuracy—volume under the receiver operating characteristic surface and the extended Youden index, with three diagnostic groups. We provide the R package DiagTest3Grp to estimate, under both parametric and nonparametric assumptions, the two summary measures and the associated variances, as well as the optimal cut-points for disease diagnosis. An omnibus test for multiple markers and a Wald test for two markers, on independent or paired samples, are incorporated to compare diagnostic accuracy across biomarkers. Sample size calculation under the normality assumption can be performed in the R package to design future diagnostic studies. A real world application evaluating the diagnostic accuracy of neuropsychological markers for Alzheimer’s disease is used to guide readers through step-by-step implementation of DiagTest3Grp to demonstrate its utility.

  8. Diagnostic utility of the glucagon stimulation test in comparison to the insulin tolerance test in patients following pituitary surgery

    DEFF Research Database (Denmark)

    Berg, Christian; Meinel, Timo; Lahner, Harald

    2009-01-01

    OBJECTIVE: The glucagon stimulation test (GST) like the insulin tolerance test (ITT) stimulates both ACTH and GH secretion. However, there are limited data with modern assays on sensitivity and specificity for GST in comparison to ITT. The aim of this study was to evaluate the diagnostic utility......). Receiver-operating characteristic (ROC) analysis was performed to identify the thresholds for GST. RESULTS: In ITT, 18/49 cases were classified as AI. ROC analysis revealed a peak cortisol value >599 nmol/l in GST for adrenal sufficiency with 100% specificity and 32% sensitivity, and a peak cortisol

  9. Estimating the true accuracy of diagnostic tests for dengue infection using bayesian latent class models.

    Directory of Open Access Journals (Sweden)

    Wirichada Pan-ngum

    Full Text Available Accuracy of rapid diagnostic tests for dengue infection has been repeatedly estimated by comparing those tests with reference assays. We hypothesized that those estimates might be inaccurate if the accuracy of the reference assays is not perfect. Here, we investigated this using statistical modeling.Data from a cohort study of 549 patients suspected of dengue infection presenting at Colombo North Teaching Hospital, Ragama, Sri Lanka, that described the application of our reference assay (a combination of Dengue IgM antibody capture ELISA and IgG antibody capture ELISA and of three rapid diagnostic tests (Panbio NS1 antigen, IgM antibody and IgG antibody rapid immunochromatographic cassette tests were re-evaluated using bayesian latent class models (LCMs. The estimated sensitivity and specificity of the reference assay were 62.0% and 99.6%, respectively. Prevalence of dengue infection (24.3%, and sensitivities and specificities of the Panbio NS1 (45.9% and 97.9%, IgM (54.5% and 95.5% and IgG (62.1% and 84.5% estimated by bayesian LCMs were significantly different from those estimated by assuming that the reference assay was perfect. Sensitivity, specificity, PPV and NPV for a combination of NS1, IgM and IgG cassette tests on admission samples were 87.0%, 82.8%, 62.0% and 95.2%, respectively.Our reference assay is an imperfect gold standard. In our setting, the combination of NS1, IgM and IgG rapid diagnostic tests could be used on admission to rule out dengue infection with a high level of accuracy (NPV 95.2%. Further evaluation of rapid diagnostic tests for dengue infection should include the use of appropriate statistical models.

  10. A compliance testing program for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Hutchinson, D.E.; Cobb, B.J.; Jacob, C.S.

    1999-01-01

    Compliance testing is nominally that part of a quality assurance program dealing with those aspects of X-ray equipment performance that are subject to radiation control legislation. Quality assurance programs for medical X-ray equipment should be an integral part of the quality culture in health care. However while major hospitals and individual medical centers may implement such programs with some diligence, much X-ray equipment can remain unappraised unless there is a comprehensive regulatory inspection program or some form of compulsion on the equipment owner to implement a testing program. Since the late 1950s all X-ray equipment in the State of Western Australia has been inspected by authorized officers acting on behalf of the Radiological Council, the regulatory authority responsible for administration of the State's Radiation Safety Act. However, economic constraints, coupled with increasing X-ray equipment numbers and a geographically large State have significantly affected the inspection rate. Data available from inspections demonstrate that regular compliance and performance checks are essential in order to ensure proper performance and to minimize unnecessary patient and operator dose. To ensure that diagnostic X-ray equipment complies with accepted standards and performance criteria, the regulatory authority introduced a compulsory compliance testing program for all medical, dental and chiropractic diagnostic X-ray equipment effective from 1 January 1997

  11. Bovine paratuberculosis: a review of the advantages and disadvantages of different diagnostic tests.

    Science.gov (United States)

    Gilardoni, Liliana R; Paolicchi, Fernando A; Mundo, Silvia L

    2012-01-01

    Paratuberculosis (PTB), or Johne's disease, is a chronic infectious granulomatous enteritis of ruminants, caused by Mycobacterium avium subspecies paratuberculosis (Map). It is characterized by diarrhea and progressive cachexia, which may cause the death of the animal. Calves are the most susceptible to infection. Infected animals excrete Map mainly by the feces. PTB is endemic worldwide, with high prevalence levels, strong economic impact and public health relevance because of its possible association with Crohn's disease. Although the current reference diagnostic test is identification of Map in the bacterial culture, there are different diagnostic tests to identify infected individuals and/or herds. The sensitivity and specificity of these tests vary according to the stage of the disease in the animals to be evaluated. The correct choice and application of each of these diagnostic tests will ensure their success and may allow to establish a control program. The aim of this work is to review and discuss the different diagnostic tests used in the detection of Map-infected animals, focusing on their advantages and disadvantages.

  12. Evidence Based Medicine; Positive and Negative Likelihood Ratios of Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Alireza Baratloo

    2015-10-01

    Full Text Available In the previous two parts of educational manuscript series in Emergency, we explained some screening characteristics of diagnostic tests including accuracy, sensitivity, specificity, and positive and negative predictive values. In the 3rd  part we aimed to explain positive and negative likelihood ratio (LR as one of the most reliable performance measures of a diagnostic test. To better understand this characteristic of a test, it is first necessary to fully understand the concept of sensitivity and specificity. So we strongly advise you to review the 1st part of this series again. In short, the likelihood ratios are about the percentage of people with and without a disease but having the same test result. The prevalence of a disease can directly influence screening characteristics of a diagnostic test, especially its sensitivity and specificity. Trying to eliminate this effect, LR was developed. Pre-test probability of a disease multiplied by positive or negative LR can estimate post-test probability. Therefore, LR is the most important characteristic of a test to rule out or rule in a diagnosis. A positive likelihood ratio > 1 means higher probability of the disease to be present in a patient with a positive test. The further from 1, either higher or lower, the stronger the evidence to rule in or rule out the disease, respectively. It is obvious that tests with LR close to one are less practical. On the other hand, LR further from one will have more value for application in medicine. Usually tests with 0.1 < LR > 10 are considered suitable for implication in routine practice.

  13. Systematic Review of Health Economic Evaluations of Diagnostic Tests in Brazil: How accurate are the results?

    Science.gov (United States)

    Oliveira, Maria Regina Fernandes; Leandro, Roseli; Decimoni, Tassia Cristina; Rozman, Luciana Martins; Novaes, Hillegonda Maria Dutilh; De Soárez, Patrícia Coelho

    2017-08-01

    The aim of this study is to identify and characterize the health economic evaluations (HEEs) of diagnostic tests conducted in Brazil, in terms of their adherence to international guidelines for reporting economic studies and specific questions in test accuracy reports. We systematically searched multiple databases, selecting partial and full HEEs of diagnostic tests, published between 1980 and 2013. Two independent reviewers screened articles for relevance and extracted the data. We performed a qualitative narrative synthesis. Forty-three articles were reviewed. The most frequently studied diagnostic tests were laboratory tests (37.2%) and imaging tests (32.6%). Most were non-invasive tests (51.2%) and were performed in the adult population (48.8%). The intended purposes of the technologies evaluated were mostly diagnostic (69.8%), but diagnosis and treatment and screening, diagnosis, and treatment accounted for 25.6% and 4.7%, respectively. Of the reviewed studies, 12.5% described the methods used to estimate the quantities of resources, 33.3% reported the discount rate applied, and 29.2% listed the type of sensitivity analysis performed. Among the 12 cost-effectiveness analyses, only two studies (17%) referred to the application of formal methods to check the quality of the accuracy studies that provided support for the economic model. The existing Brazilian literature on the HEEs of diagnostic tests exhibited reasonably good performance. However, the following points still require improvement: 1) the methods used to estimate resource quantities and unit costs, 2) the discount rate, 3) descriptions of sensitivity analysis methods, 4) reporting of conflicts of interest, 5) evaluations of the quality of the accuracy studies considered in the cost-effectiveness models, and 6) the incorporation of accuracy measures into sensitivity analyses.

  14. Consensus-based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants

    DEFF Research Database (Denmark)

    Gardner, Ian A.; Nielsen, Søren Saxmose; Whittington, Richard

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy...... studies and the finding that incomplete or absent reporting of items in the STARD checklist was associated with overly optimistic estimates of test performance characteristics. Although STARD principles apply broadly, specific guidelines do not exist to account for unique considerations in livestock...... for Reporting of Animal Diagnostic Accuracy Studies for paratuberculosis), should facilitate improved quality of reporting of the design, conduct and results of paratuberculosis test accuracy studies which were identified as “poor” in a review published in 2008 in Veterinary Microbiology...

  15. Translating microarray data for diagnostic testing in childhood leukaemia

    International Nuclear Information System (INIS)

    Hoffmann, Katrin; Firth, Martin J; Beesley, Alex H; Klerk, Nicholas H de; Kees, Ursula R

    2006-01-01

    Recent findings from microarray studies have raised the prospect of a standardized diagnostic gene expression platform to enhance accurate diagnosis and risk stratification in paediatric acute lymphoblastic leukaemia (ALL). However, the robustness as well as the format for such a diagnostic test remains to be determined. As a step towards clinical application of these findings, we have systematically analyzed a published ALL microarray data set using Robust Multi-array Analysis (RMA) and Random Forest (RF). We examined published microarray data from 104 ALL patients specimens, that represent six different subgroups defined by cytogenetic features and immunophenotypes. Using the decision-tree based supervised learning algorithm Random Forest (RF), we determined a small set of genes for optimal subgroup distinction and subsequently validated their predictive power in an independent patient cohort. We achieved very high overall ALL subgroup prediction accuracies of about 98%, and were able to verify the robustness of these genes in an independent panel of 68 specimens obtained from a different institution and processed in a different laboratory. Our study established that the selection of discriminating genes is strongly dependent on the analysis method. This may have profound implications for clinical use, particularly when the classifier is reduced to a small set of genes. We have demonstrated that as few as 26 genes yield accurate class prediction and importantly, almost 70% of these genes have not been previously identified as essential for class distinction of the six ALL subgroups. Our finding supports the feasibility of qRT-PCR technology for standardized diagnostic testing in paediatric ALL and should, in conjunction with conventional cytogenetics lead to a more accurate classification of the disease. In addition, we have demonstrated that microarray findings from one study can be confirmed in an independent study, using an entirely independent patient cohort

  16. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples

    Science.gov (United States)

    Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David

    2017-01-01

    transport of samples from endemic to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65–88%), compared to the sensitivity (91–100%) of the new molecular diagnostic workflow. Conclusions/Significance Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited. PMID:28915255

  17. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples.

    Directory of Open Access Journals (Sweden)

    Nichola Eliza Davies Calvani

    2017-09-01

    to non-endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65-88%, compared to the sensitivity (91-100% of the new molecular diagnostic workflow.Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited.

  18. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples.

    Science.gov (United States)

    Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David; Šlapeta, Jan

    2017-09-01

    -endemic countries without the requirement of a complete cold chain. The commercially-available ELISA displayed poorer sensitivity, even after adjustment of the positive threshold (65-88%), compared to the sensitivity (91-100%) of the new molecular diagnostic workflow. Species-specific assays for sensitive detection of Fasciola spp. enable ante-mortem diagnosis in both human and animal settings. This includes Southeast Asia where there are potentially many undocumented human cases and where post-mortem examination of production animals can be difficult. The new molecular workflow provides a sensitive and quantitative diagnostic approach for the rapid testing of medium to large sample sizes, potentially superseding the traditional sedimentation and FEC technique and enabling surveillance programs in locations where animal and human health funding is limited.

  19. Reactor protection system with automatic self-testing and diagnostic

    International Nuclear Information System (INIS)

    Gaubatz, D.C.

    1996-01-01

    A reactor protection system is disclosed having four divisions, with quad redundant sensors for each scram parameter providing input to four independent microprocessor-based electronic chassis. Each electronic chassis acquires the scram parameter data from its own sensor, digitizes the information, and then transmits the sensor reading to the other three electronic chassis via optical fibers. To increase system availability and reduce false scrams, the reactor protection system employs two levels of voting on a need for reactor scram. The electronic chassis perform software divisional data processing, vote 2/3 with spare based upon information from all four sensors, and send the divisional scram signals to the hardware logic panel, which performs a 2/4 division vote on whether or not to initiate a reactor scram. Each chassis makes a divisional scram decision based on data from all sensors. Automatic detection and discrimination against failed sensors allows the reactor protection system to automatically enter a known state when sensor failures occur. Cross communication of sensor readings allows comparison of four theoretically ''identical'' values. This permits identification of sensor errors such as drift or malfunction. A diagnostic request for service is issued for errant sensor data. Automated self test and diagnostic monitoring, sensor input through output relay logic, virtually eliminate the need for manual surveillance testing. This provides an ability for each division to cross-check all divisions and to sense failures of the hardware logic. 16 figs

  20. [Pilot tests using molecular diagnostic assay cervicovaginal infection during pregnancy].

    Science.gov (United States)

    Beltrán-Montoya, J; Escudero-Gontes, S; Martínez-Huerta, N E; Ávila-Vergara, M A; Morales-Hernández, V; Canchola-Sotelo, C; Palacios-González, B; Vadillo-Ortega, F

    2016-08-01

    The prevalence of cervicovaginal infections during pregnancy has been associated with adverse perinatal outcomes however, the actual approach used for diagnosis is not effective. The aim of this study was to compare the diagnosis of vaginal infections in pregnant women using clinical, molecular diagnostic and traditional microbiological culture in a pilot study, to determine the prevalence and association with the development of preterm labor. We performed a nested cross-sectional study composed by 54 women in a cohort of pregnant women in Mexico City. Cervicovaginal infections were evaluated by clinical methods, microbiology culture and a commercially available molecular biology test. Prevalence of cervicovaginal infections during pregnancy was estimated between 28% and 50% according to methodologies. Considering the clinical diagnosis of preterm labor as the gold standard, all diagnostic tests were poor as predictors of preterm labor. Traditional approaches to establish the significance of cervicovaginal infection in pregnancy are exhausted, so be sought new ways to understand this complex relationship. Meanwhile it is recommended to continue to use traditional methods to identify infections during pregnancy in both knowledge of new methods aimed at understanding these relationships are sophisticated.

  1. The bone diagnostic instrument III: Testing mouse femora

    Science.gov (United States)

    Randall, Connor; Mathews, Phillip; Yurtsev, Eugene; Sahar, Nadder; Kohn, David; Hansma, Paul

    2009-06-01

    Here we describe modifications that allow the bone diagnostic instrument (BDI) [P. Hansma et al., Rev. Sci. Instrum. 79, 064303 (2008); Rev. Sci. Instrum. 77, 075105 (2006)], developed to test human bone, to test the femora of mice. These modifications include reducing the effective weight of the instrument on the bone, designing and fabricating new probe assemblies to minimize damage to the small bone, developing new testing protocols that involve smaller testing forces, and fabricating a jig for securing the smaller bones for testing. With these modifications, the BDI was used to test the hypothesis that short-term running has greater benefit on the mechanical properties of the femur for young growing mice compared to older, skeletally mature mice. We measured elastic modulus, hardness, and indentation distance increase (IDI), which had previously been shown to be the best discriminators in model systems known to exhibit differences in mechanical properties at the whole bone level. In the young exercised murine femora, the IDI was significantly lower than in young control femora. Since IDI has a relation to postyield properties, these results suggest that exercise during bone development increases post yield mechanical competence. We were also able to measure effects of aging on bone properties with the BDI. There was a significant increase in the IDI, and a significant decrease in the elastic modulus and hardness between the young and old groups. Thus, with the modifications described here, the BDI can take measurements on mouse bones and obtain statistically significant results.

  2. Femoroacetabular cam-type impingement: Diagnostic sensitivity and specificity of radiographic views compared to radial MRI

    International Nuclear Information System (INIS)

    Domayer, S.E.; Ziebarth, K.; Chan, J.; Bixby, S.; Mamisch, T.C.; Kim, Y.J.

    2011-01-01

    Purpose: To retrospectively assess the diagnostic sensitivity of 45° Dunn view and cross-table lateral radiographs for the assessment of cam deformity by comparison with radial MRI. Materials and methods: 60 cases with radiographs (38 a–p and 45° Dunn views, 22 a–p and cross-table lateral views) and radial MRI were assessed. Alpha angle measurements were obtained both for radiographs and radial MRI. Statistics included frequency analysis, bivariate linear correlation analyses of MRI and radiograph measurements and cross-table analyses testing for the sensitivity and specificity of radiographs for the detection of an alpha angle larger than 55°. Results: 53.3% had the maximum alpha angle in the superior–anterior aspect of the femoral head–neck junction. Cam deformity was found in 45/60 cases (75%) in radial MRI. Pearson correlation demonstrated the Dunn view was most accurate for the superior–anterior aspect (.772, P < .001). The cross-table lateral views were best suited for the anterior–superior aspect (.511, P < .05). The sensitivity for cam deformity in the Dunn view was 96.4% vs. 70.6% in the cross-table lateral view. Conclusion: The 45° Dunn view can improve the first line of impingement diagnostics. Radial MRI however remains indispensable for pre-operative planning and the evaluation of symptomatic cases without obvious deformity.

  3. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

    Directory of Open Access Journals (Sweden)

    Wilfredo R Matias

    Full Text Available Rapid diagnostic tests (RDT for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7% were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6% and 71.1% (95%CI: 64.7%-76.9%, respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100% and specificity of 69.1% (95%CI: 55.2%-80.9%. SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8% and specificity of 92.8% (95%CI: 88.4%-95.9%. Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

  4. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Science.gov (United States)

    2010-01-01

    ... samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... for diagnostic testing. (b) The authorized laboratory must identify each egg as to the breeding flock...

  5. Usage of Latent Class Analysis in Diagnostic Microbiology in the Absence of Gold Standard Test

    Directory of Open Access Journals (Sweden)

    Gul Bayram Abiha

    2016-12-01

    Full Text Available The evaluation of performance of various tests diagnostic tests in the absence of gold standard is an important problem. Latent class analysis (LCA is a statistical analysis method known for many years, especially in the absence of a gold standard for evaluation of diagnostic tests so that LCA has found its wide application area. During the last decade, LCA method has widely used in for determining sensivity and specifity of different microbiological tests. It has investigated in the diagnosis of mycobacterium tuberculosis, mycobacterium bovis, human papilloma virus, bordetella pertussis, influenza viruses, hepatitis E virus (HEV, hepatitis C virus (HCV and other various viral infections. Researchers have compared several diagnostic tests for the diagnosis of different pathogens with LCA. We aimed to evaluate performance of latent class analysis method used microbiological diagnosis in various diseases in several researches. When we took into account all of these tests' results, we suppose that LCA is a good statistical analysis method to assess different test performances in the absence of gold standard. [Archives Medical Review Journal 2016; 25(4.000: 467-488

  6. Self Diagnostic Accelerometer Testing on the C-17 Aircraft

    Science.gov (United States)

    Tokars, Roger P.; Lekki, John D.

    2013-01-01

    The self diagnostic accelerometer (SDA) developed by the NASA Glenn Research Center was tested for the first time in an aircraft engine environment as part of the Vehicle Integrated Propulsion Research (VIPR) program. The VIPR program includes testing multiple critical flight sensor technologies. One such sensor, the accelerometer, measures vibrations to detect faults in the engine. In order to rely upon the accelerometer, the health of the accelerometer must be ensured. The SDA is a sensor system designed to actively determine the accelerometer structural health and attachment condition, in addition to vibration measurements. The SDA uses a signal conditioning unit that sends an electrical chirp to the accelerometer and recognizes changes in the response due to changes in the accelerometer health and attachment condition. To demonstrate the SDAs flight worthiness and robustness, multiple SDAs were mounted and tested on a C-17 aircraft engine. The engine test conditions varied from engine off, to idle, to maximum power. The SDA attachment conditions were varied from fully tight to loose. The newly developed SDA health algorithm described herein uses cross correlation pattern recognition to discriminate a healthy from a faulty SDA. The VIPR test results demonstrate for the first.

  7. [Diagnostic Accuracy of the LiSe-DaZ for Children with Specific Language Impairment].

    Science.gov (United States)

    Stephan, T; Keilmann, A

    2015-12-01

    Currently, only few tests for the development of speech and language exist for bi- or multilingual children in Germany. One of those, the LiSe-DaZ (Linguistic performance measurement - German as a second language), was examined in a prospective study regarding its practicability and the sensitivity to detect children with specific language impairment in a group of children aged 5 to 7 who suffered from a severe language impairment according to clinical tests. 74 children (mean age: 60 months; 46% monolingual German-speaking; 54% bi- or multilingual) with severe specific language impairment were examined with the LiSe-DaZ in addition to the clinical established diagnostic during their in-patient stay in the hospital. The children, on average, showed in the receptive language abilities (LiSe-DaZ vs. TROG-D), the expressive vocabulary (LiSe-DaZ vs. AWST-R or WWT) and in the use of prepositions (LiSe-DaZ vs. Ravensburger Dysgrammatical clinical trial) significantly (pchildren were diagnosed as language impaired by clinically established tests whereas the LiSe-DaZ considered the children's language development to be normal. This difference was consistently more prominent for children with German as a second language. Compared with the clinically established tests, the informative value of the LiSe-DaZ turned out to be insufficient. The LiSe-DaZ does not detect children with the need of language therapy. Nevertheless, a norming of the established speech tests for bi- or multilingual children would be desirable to avoid unfounded judgements. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Safety of a rapid diagnostic protocol with accelerated stress testing.

    Science.gov (United States)

    Soremekun, Olan A; Hamedani, Azita; Shofer, Frances S; O'Conor, Katie J; Svenson, James; Hollander, Judd E

    2014-02-01

    Most patients at low to intermediate risk for an acute coronary syndrome (ACS) receive a 12- to 24-hour "rule out." Recently, trials have found that a coronary computed tomographic angiography-based strategy is more efficient. If stress testing were performed within the same time frame as coronary computed tomographic angiography, the 2 strategies would be more similar. We tested the hypothesis that stress testing can safely be performed within several hours of presentation. We performed a retrospective cohort study of patients presenting to a university hospital from January 1, 2009, to December 31, 2011, with potential ACS. Patients placed in a clinical pathway that performed stress testing after 2 negative troponin values 2 hours apart were included. We excluded patients with ST-elevation myocardial infarction or with an elevated initial troponin. The main outcome was safety of immediate stress testing defined as the absence of death or acute myocardial infarction (defined as elevated troponin within 24 hours after the test). A total of 856 patients who presented with potential ACS were enrolled in the clinical pathway and included in this study. Patients had a median age of 55.0 (interquartile range, 48-62) years. Chest pain was the chief concern in 86%, and pain was present on arrival in 73% of the patients. There were no complications observed during the stress test. There were 0 deaths (95% confidence interval, 0%-0.46%) and 4 acute myocardial infarctions within 24 hours (0.5%; 95% confidence interval, 0.14%-1.27%). The peak troponins were small (0.06, 0.07, 0.07, and 0.19 ng/mL). Patients who present to the ED with potential ACS can safely undergo a rapid diagnostic protocol with stress testing. © 2013.

  9. Recent Progress in the Development of Diagnostic Tests for Malaria.

    Science.gov (United States)

    Krampa, Francis D; Aniweh, Yaw; Awandare, Gordon A; Kanyong, Prosper

    2017-09-19

    The impact of malaria on global health has continually prompted the need to develop effective diagnostic strategies. In malaria endemic regions, routine diagnosis is hampered by technical and infrastructural challenges to laboratories. These laboratories lack standard facilities, expertise or diagnostic supplies; thus, therapy is administered based on clinical or self-diagnosis. There is the need for accurate diagnosis of malaria due to the continuous increase in the cost of medication, and the emergence and spread of drug resistant strains. However, the widely utilized Giemsa-stained microscopy and immunochromatographic tests for malaria are liable to several drawbacks, including inadequate sensitivity and false-positive outcomes. Alternative methods that offer improvements in performance are either expensive, have longer turnaround time or require a level of expertise that makes them unsuitable for point-of-care (POC) applications. These gaps necessitate exploration of more efficient detection techniques with the potential of POC applications, especially in resource-limited settings. This minireview discusses some of the recent trends and new approaches that are seeking to improve the clinical diagnosis of malaria.

  10. Recent Progress in the Development of Diagnostic Tests for Malaria

    Directory of Open Access Journals (Sweden)

    Francis D. Krampa

    2017-09-01

    Full Text Available The impact of malaria on global health has continually prompted the need to develop effective diagnostic strategies. In malaria endemic regions, routine diagnosis is hampered by technical and infrastructural challenges to laboratories. These laboratories lack standard facilities, expertise or diagnostic supplies; thus, therapy is administered based on clinical or self-diagnosis. There is the need for accurate diagnosis of malaria due to the continuous increase in the cost of medication, and the emergence and spread of drug resistant strains. However, the widely utilized Giemsa-stained microscopy and immunochromatographic tests for malaria are liable to several drawbacks, including inadequate sensitivity and false-positive outcomes. Alternative methods that offer improvements in performance are either expensive, have longer turnaround time or require a level of expertise that makes them unsuitable for point-of-care (POC applications. These gaps necessitate exploration of more efficient detection techniques with the potential of POC applications, especially in resource-limited settings. This minireview discusses some of the recent trends and new approaches that are seeking to improve the clinical diagnosis of malaria.

  11. Prospective evaluation of three rapid diagnostic tests for diagnosis of human leptospirosis.

    Directory of Open Access Journals (Sweden)

    Marga G A Goris

    Full Text Available BACKGROUND: Diagnosis of leptospirosis by the microscopic agglutination test (MAT or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively. METHODOLOGY: During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1(st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness. RESULTS: The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1(st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB, but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB. CONCLUSIONS: All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.

  12. Diagnostic significance of haematological testing in patients presenting at the Emergency Department

    Directory of Open Access Journals (Sweden)

    Giuseppe Lippi

    2012-03-01

    Full Text Available The use of simple and economic tests to rule out diseases of sufficient clinical severity is appealing in emergency department (ED, since it would be effective for contrasting ED overcrowding and decreasing healthcare costs. The aim of this study was to assess the diagnostic performance of simple and economic haematological testing in a large sample of adult patients presenting at the ED of the Academic Hospital of Parma during the year 2010 with the five most frequent acute pathologies (i.e., acute myocardial infarction, renal colic, pneumonia, trauma and pancreatitis. Both leukocyte count and hemoglobin showed a good diagnostic performance (Area Under the Curve [AUC] of 0.85 for leukocyte count and 0.76 for hemoglobin; both p < 0.01. Although the platelet count was significantly increased in all patients groups except pancreatitis, the diagnostic performance did not achieve statistical significance (AUC 0.53; p = 0.07. We also observed an increased RDW in all groups, except in those with trauma and the diagnostic performance was acceptable (AUC 0.705; p < 0.01. The mean platelet volume (MPV was consistently lower in all patients groups and also characterized by an efficient diagnostic performance (AUC 0.76; p < 0.01. This evidence led us to design an arbitrary formula, whereby MPV and hemoglobin were multiplied, and further divided by the leukocyte count, obtaining a remarkable AUC (0.91; p < 0.01. We conclude that simple, rapid and cheap hematological tests might provide relevant clinical information for decision making to busy emergency physicians, and the their combination into an arbitrary formula might further increase the specific diagnostic potential of each of them.

  13. Diagnostic Efficacy of Modified Coagglutination Test in the Diagnosis of Human Brucellosis

    Directory of Open Access Journals (Sweden)

    Mohite S.T

    2013-07-01

    Full Text Available Background: Laboratory help is must for thediagnosis of human brucellosis due to proteanclinical manifestations. As culture is hazardous,time consuming and less sensitive, serologicaltests are preferred for the diagnosis. Aggluti-nation tests like Rose Bengal PlateTest (RBPT, Serum Agglutination tests (SAT,2-Mercaptoethanol test (2-ME that are com-monly employed for the diagnosis either lacksensitivity or specificity. Coombs test andBrucellacapt though are sensitive and specific,workout costly. Therefore, modifiedcoagglutination test was developed and its di-agnostic efficacy was evaluated. Aims and Ob-jectives: To develop modified coagglutinationtest for the diagnosis of human brucellosis andcompare it with Coombs test. Materials andMethods: Serum samples collected from 191brucellosis patients and 100 controls were sub-jected to 2-ME, Coombs test and modifiedcoagglutination test (MCOAG. Blood culturewas performed by Castaneda’s method in all thepatients. Results: Significant difference in thepositivity rate was seen between MCOAG and2-ME. The results of MCOAG were compa-rable with Coombs test. Conclusions: Modi-fied coagglutination test is a better option toCoombs test for the serodiagnosis of brucel-losis in resource constrained countries as it issensitive, specific and cost effective.

  14. Applications of optical fibers in nuclear test diagnostics

    International Nuclear Information System (INIS)

    Lyons, P.B.; Hodson, E.K.; Looney, L.D.

    1980-01-01

    Two new plasma diagnostic experiments have been successfully fielded on nuclear device tests at NTS. Both systems rely on the unique advantages provided by optical fiber technology and both systems provide new diagnostic capabilities that previously were beyond the state-of-the-art in coaxial cable systems. One system addresses the need to record e wide bandwidth data on gamma-ray sources. Over the long (< 1 km) distances that characterize NTS testing, the bandwidth of coaxial cable systems is usually limited to < 200 to 400 MHz even with extensive equalization. The new system uses the Cerenkov process to generate light in a converter material. High bandwidth fibers and detectors are used to approach a 1-GHz bandwidth. In this case fibers provided the bandwidth capability. The second system provides time and space resolution of a neutron source on a fast (ns) time scale. Previous systems have utilized either an array of neutron detectors with individual coaxial cables or a fast scintillator viewed by a gated image intensifier. For a large number of channels, the coaxial system becomes very costly and is subject to potentially severe EMI concerns. The gated intensifier system requires complex electronics and accurate timing and can be affected by EMI. An alternative system is described which provides continuous time coverage with limited spatial resolution. Complete freedom from EMI is achieved through the use of optical data collection and transmission. The optical fibers offered a major (2 to 3 times) cost savings and a large weight savings relative to the coax system. Each system is discussed

  15. Review: Diagnostic accuracy of PCR-based detection tests for Helicobacter Pylori in stool samples.

    Science.gov (United States)

    Khadangi, Fatemeh; Yassi, Maryam; Kerachian, Mohammad Amin

    2017-12-01

    Although different methods have been established to detect Helicobacter pylori (H. pylori) infection, identifying infected patients is an ongoing challenge. The aim of this meta-analysis was to provide pooled diagnostic accuracy measures for stool PCR test in the diagnosis of H. pylori infection. In this study, a systematic review and meta-analysis were carried out on various sources, including MEDLINE, Web of Sciences, and the Cochrane Library from April 1, 1999, to May 1, 2016. This meta-analysis adheres to the guidelines provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses report (PRISMA Statement). The clinical value of DNA stool PCR test was based on the pooled false positive, false negative, true positive, and true negative of different genes. Twenty-six of 328 studies identified met the eligibility criteria. Stool PCR test had a performance of 71% (95% CI: 68-73) sensitivity, 96% (95% CI: 94-97) specificity, and 65.6 (95% CI: 30.2-142.5) diagnostic odds ratio (DOR) in diagnosis of H. pylori. The DOR of genes which showed the highest performance of stool PCR tests was as follows: 23S rRNA 152.5 (95% CI: 55.5-418.9), 16S rRNA 67.9 (95%CI: 6.4-714.3), and glmM 68.1 (95%CI: 20.1-231.7). The sensitivity and specificity of stool PCR test are relatively in the same spectrum of other diagnostic methods for the detection of H. pylori infection. In descending order of significance, the most diagnostic candidate genes using PCR detection were 23S rRNA, 16S rRNA, and glmM. PCR for 23S rRNA gene which has the highest performance could be applicable to detect H. pylori infection. © 2017 John Wiley & Sons Ltd.

  16. More than just T₄: diagnostic testing for hyperthyroidism in cats.

    Science.gov (United States)

    Peterson, Mark E

    2013-09-01

    In older cats presenting with clinical features of hyperthyroidism, confirmation of a diagnosis of thyroid disease is usually straightforward. However, the potential for false-negative and false-positive results exists with all thyroid function tests (especially in the context of routine screening of asymptomatic cats) and leads to clinical dilemmas. For example, a high serum T₄ value may be found in a cat that lacks clinical signs of hyperthyroidism, or hyperthyroidism may be suspected in a cat with normal total T₄ concentrations. To avoid unnecessary treatment and potentially adverse effects in a euthyroid cat, thyroid function tests must always be interpreted in the light of the cat's history, clinical signs, physical examination findings and other laboratory findings. In this article the author reviews the use of commonly recommended thyroid function tests, focusing on clinical scenarios that present diagnostic difficulties. In doing so, he draws on the veterinary and comparative literature, his own clinical experience, and data, unpublished to date, obtained from a series of 100 hyperthyroid cats consecutively diagnosed at his clinic.

  17. 30 CFR 250.520 - When do I have to perform a casing diagnostic test?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When do I have to perform a casing diagnostic... Operations Casing Pressure Management § 250.520 When do I have to perform a casing diagnostic test? (a) You must perform a casing diagnostic test within 30 days after first observing or imposing casing pressure...

  18. Reporting Diagnostic Scores in Educational Testing: Temptations, Pitfalls, and Some Solutions

    Science.gov (United States)

    Sinharay, Sandip; Puhan, Gautam; Haberman, Shelby J.

    2010-01-01

    Diagnostic scores are of increasing interest in educational testing due to their potential remedial and instructional benefit. Naturally, the number of educational tests that report diagnostic scores is on the rise, as are the number of research publications on such scores. This article provides a critical evaluation of diagnostic score reporting…

  19. Diagnostic Accuracy of Quantitative Sensory Testing to Discriminate Inflammatory Toothache and Intraoral Neuropathic Pain.

    Science.gov (United States)

    Porporatti, André Luís; Costa, Yuri Martins; Stuginski-Barbosa, Juliana; Bonjardim, Leonardo Rigoldi; Duarte, Marco Antônio Hungaro; Conti, Paulo César Rodrigues

    2015-10-01

    A differential diagnosis between inflammatory toothache (IT) and intraoral neuropathic pain is challenging. The aim of this diagnostic study was to quantify somatosensory function of subjects with IT (acute pulpitis) and atypical odontalgia (AO, intraoral neuropathic pain) and healthy volunteers and to quantify how accurately quantitative sensory testing (QST) discriminates an IT or AO diagnosis. The sample consisted of 60 subjects equally divided (n = 20) into 3 groups: (1) IT, (2) AO, and (3) control. A sequence of 4 QST methods was performed over the dentoalveolar mucosa in the apical maxillar or mandibular area: mechanical detection threshold, pain detection threshold (PDT), dynamic mechanical allodynia, and temporal summation. One-way analysis of variance, Tukey post hoc analyses, and z score transformation were applied to the data. In addition, the receiver operating characteristic curve analysis, diagnostic accuracy, sensitivity, specificity, likelihood ratios, and diagnostic odds ratio of the QST methods were calculated (α = 5%). Somatosensory abnormalities were found for the AO group, which is consistent with a low detection threshold to touch and pain and the presence of mechanical allodynia. For the IT group, no somatosensory abnormality was observed when compared with the control group. The most accurate QST to discriminate the diagnostic differences between IT and healthy individuals is the PDT. The diagnostic differences between AO and healthy individuals and between IT and AO are best discriminated with the mechanical detection threshold, PDT, and dynamic mechanical allodynia. The proposed QST methods may aid in the differential diagnosis between IT and AO with strong accuracy and may be used as complementary diagnostic tests. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  20. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    Science.gov (United States)

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  1. Comparison of diagnostic accuracy of non invasive tests for helicobacter pylori infection in children

    International Nuclear Information System (INIS)

    Hafeez, A.; Haseeb, H.A.H.; Bilal, R.; Latif, Z.

    2007-01-01

    To compare urea breath and stool antigen in children, with histological diagnosis for Helicobacter pylori (H.pylori) infection. Children between 3 and 15 years of age reporting in pediatric outpatient department with upper gastrointestinal symptoms were included. All the participating children underwent an upper gastrointestinal endoscopy and 3 tests namely: histopathological identification of H. pylori (the traditional gold standard), urea breath test and stool antigen test were carried out on each child. The sensitivity, specificity, and positive predictive values were calculated for each noninvasive test used in the study. A total of 54 patients completed the study with a mean age of 8.2 years. On histological examination, 72% (39) were positive for H. pylori infection. On gross endoscopic examination, only 9 patients had signs of gastritis as compared to 39 histological positives. The sensitivity, specificity and positive predictive value of stool antigen test were: 77%, 73% and 89% respectively whereas the same for urea breath test were: 79%, 80% and 91% respectively. Both the noninvasive tests were found to be sensitive and specific as compared with histological identification, for the diagnosis of H. pylori in our pediatric population. The accuracy of urea breath test was better than the stool antigen test but later was easier to perform and could fulfill the criteria for a rapid bedside diagnostic test. (author)

  2. Sensitivity and specificity of proposed DSM-5 diagnostic criteria for autism spectrum disorder.

    Science.gov (United States)

    McPartland, James C; Reichow, Brian; Volkmar, Fred R

    2012-04-01

    This study evaluated the potential impact of proposed DSM-5 diagnostic criteria for autism spectrum disorder (ASD). The study focused on a sample of 933 participants evaluated during the DSM-IV field trial; 657 carried a clinical diagnosis of an ASD, and 276 were diagnosed with a non-autistic disorder. Sensitivity and specificity for proposed DSM-5 diagnostic criteria were evaluated using field trial symptom checklists as follows: individual field trial checklist items (e.g., nonverbal communication); checklist items grouped together as described by a single DSM-5 symptom (e.g., nonverbal and verbal communication); individual DSM-5 criterion (e.g., social-communicative impairment); and overall diagnostic criteria. When applying proposed DSM-5 diagnostic criteria for ASD, 60.6% (95% confidence interval: 57%-64%) of cases with a clinical diagnosis of an ASD met revised DSM-5 diagnostic criteria for ASD. Overall specificity was high, with 94.9% (95% confidence interval: 92%-97%) of individuals accurately excluded from the spectrum. Sensitivity varied by diagnostic subgroup (autistic disorder = 0.76; Asperger's disorder = 0.25; pervasive developmental disorder-not otherwise specified = 0.28) and cognitive ability (IQ criteria could substantially alter the composition of the autism spectrum. Revised criteria improve specificity but exclude a substantial portion of cognitively able individuals and those with ASDs other than autistic disorder. A more stringent diagnostic rubric holds significant public health ramifications regarding service eligibility and compatibility of historical and future research. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  3. Diagnostic validation of three test methods for detection of cyprinid herpesvirus 3 (CyHV-3).

    Science.gov (United States)

    Clouthier, Sharon C; McClure, Carol; Schroeder, Tamara; Desai, Megan; Hawley, Laura; Khatkar, Sunita; Lindsay, Melissa; Lowe, Geoff; Richard, Jon; Anderson, Eric D

    2017-03-06

    Cyprinid herpesvirus 3 (CyHV-3) is the aetiological agent of koi herpesvirus disease in koi and common carp. The disease is notifiable to the World Organisation for Animal Health. Three tests-quantitative polymerase chain reaction (qPCR), conventional PCR (cPCR) and virus isolation by cell culture (VI)-were validated to assess their fitness as diagnostic tools for detection of CyHV-3. Test performance metrics of diagnostic accuracy were sensitivity (DSe) and specificity (DSp). Repeatability and reproducibility were measured to assess diagnostic precision. Estimates of test accuracy, in the absence of a gold standard reference test, were generated using latent class models. Test samples originated from wild common carp naturally exposed to CyHV-3 or domesticated koi either virus free or experimentally infected with the virus. Three laboratories in Canada participated in the precision study. Moderate to high repeatability (81 to 99%) and reproducibility (72 to 97%) were observed for the qPCR and cPCR tests. The lack of agreement observed between some of the PCR test pair results was attributed to cross-contamination of samples with CyHV-3 nucleic acid. Accuracy estimates for the PCR tests were 99% for DSe and 93% for DSp. Poor precision was observed for the VI test (4 to 95%). Accuracy estimates for VI/qPCR were 90% for DSe and 88% for DSp. Collectively, the results show that the CyHV-3 qPCR test is a suitable tool for surveillance, presumptive diagnosis and certification of individuals or populations as CyHV-3 free.

  4. Diagnostic Methods of Helicobacter pylori Infection for Epidemiological Studies: Critical Importance of Indirect Test Validation.

    Science.gov (United States)

    Miftahussurur, Muhammad; Yamaoka, Yoshio

    2016-01-01

    Among the methods developed to detect H. pylori infection, determining the gold standard remains debatable, especially for epidemiological studies. Due to the decreasing sensitivity of direct diagnostic tests (histopathology and/or immunohistochemistry [IHC], rapid urease test [RUT], and culture), several indirect tests, including antibody-based tests (serology and urine test), urea breath test (UBT), and stool antigen test (SAT) have been developed to diagnose H. pylori infection. Among the indirect tests, UBT and SAT became the best methods to determine active infection. While antibody-based tests, especially serology, are widely available and relatively sensitive, their specificity is low. Guidelines indicated that no single test can be considered as the gold standard for the diagnosis of H. pylori infection and that one should consider the method's advantages and disadvantages. Based on four epidemiological studies, culture and RUT present a sensitivity of 74.2-90.8% and 83.3-86.9% and a specificity of 97.7-98.8% and 95.1-97.2%, respectively, when using IHC as a gold standard. The sensitivity of serology is quite high, but that of the urine test was lower compared with that of the other methods. Thus, indirect test validation is important although some commercial kits propose universal cut-off values.

  5. A COMPUTERIZED DIAGNOSTIC COMPLEX FOR RELIABILITY TESTING OF ELECTRIC MACHINES

    Directory of Open Access Journals (Sweden)

    O.О. Somka

    2015-06-01

    Full Text Available Purpose. To develop a diagnostic complex meeting the criteria and requirements for carrying out accelerated reliability test and realizing the basic modes of electric machines operation and performance of the posed problems necessary in the process of such test. Methodology. To determine and forecast the indices of electric machines reliability in accordance with the statistic data of repair plants we have conditionally divided them into structural parts that are most likely to fail. We have preliminarily assessed the state of each of these parts, which includes revelation of faults and deviations of technical and geometric parameters. We have determined the analyzed electric machine controlled parameters used for assessment of quantitative characteristics of reliability of these parts and electric machines on the whole. Results. As a result of the research, we have substantiated the structure of a computerized complex for electric machines reliability test. It allows us to change thermal and vibration actions without violation of the physics of the processes of aging and wearing of the basic structural parts and elements material. The above mentioned makes it possible to considerably reduce time spent on carrying out electric machines reliability tests and improve trustworthiness of the data obtained as a result of their performance. Originality. A special feature of determination of the controlled parameters consists in removal of vibration components in the idle mode and after disconnection of the analyzed electric machine from the power supply with the aim of singling out the vibration electromagnetic component, fixing the degree of sparking and bend of the shaft by means of phototechnique and local determination of structural parts temperature provided by corresponding location of thermal sensors. Practical value. We have offered a scheme of location of thermal and vibration sensors, which allows improvement of parameters measuring accuracy

  6. A simple nomogram for sample size for estimating sensitivity and specificity of medical tests

    Directory of Open Access Journals (Sweden)

    Malhotra Rajeev

    2010-01-01

    Full Text Available Sensitivity and specificity measure inherent validity of a diagnostic test against a gold standard. Researchers develop new diagnostic methods to reduce the cost, risk, invasiveness, and time. Adequate sample size is a must to precisely estimate the validity of a diagnostic test. In practice, researchers generally decide about the sample size arbitrarily either at their convenience, or from the previous literature. We have devised a simple nomogram that yields statistically valid sample size for anticipated sensitivity or anticipated specificity. MS Excel version 2007 was used to derive the values required to plot the nomogram using varying absolute precision, known prevalence of disease, and 95% confidence level using the formula already available in the literature. The nomogram plot was obtained by suitably arranging the lines and distances to conform to this formula. This nomogram could be easily used to determine the sample size for estimating the sensitivity or specificity of a diagnostic test with required precision and 95% confidence level. Sample size at 90% and 99% confidence level, respectively, can also be obtained by just multiplying 0.70 and 1.75 with the number obtained for the 95% confidence level. A nomogram instantly provides the required number of subjects by just moving the ruler and can be repeatedly used without redoing the calculations. This can also be applied for reverse calculations. This nomogram is not applicable for testing of the hypothesis set-up and is applicable only when both diagnostic test and gold standard results have a dichotomous category.

  7. Technical specification of HANARO fuel test loop

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. Y

    1998-03-01

    The design and installation of the irradiation test facility for verification test of the fuel performance are very important in connection with maximization of the utilization of HANARO. HANARO fuel test loop was designed in accordance with the same code and standards of nuclear power plant because HANARO FTL will be operated the high pressure and temperature same as nuclear power plant operation conditions. The objective of this study is to confirm the operation limit, safety limit, operation condition and checking points of HANARO fuel test loop. This results will become guidances for the planning of irradiation testing and operation of HANARO fuel test loop. (author). 13 refs., 13 tabs., 8 figs.

  8. Molecular diagnostic for boll weevil (Coleoptera: Curculionidae) based on amplification of three species-specific microsatellites.

    Science.gov (United States)

    Kim, Kyung Seok; Szendrei, Zsofia; Rodriguez-Saona, Cesar; Mulder, Phillip G; Sappington, Thomas W

    2009-04-01

    The boll weevil, Anthonomus grandis grandis Boheman (Coleoptera: Curculionidae), is a serious pest of cultivated cotton, Gossypium hirsutum L., in the Americas, and reinfestation of zones from which they have been eradicated is of perpetual concern. Extensive arrays of pheromone traps monitor for reintroductions, but occasionally the traps collect nontarget weevils that can be misidentified by scouts. For example, the congeneric pepper weevil, Anthonomus eugenii Cano, and other superficially similar weevils are attracted to components of the boll weevil lure or trap color. Although morphologically distinguishable by trained personnel, the potential for misidentification is compounded when captured weevils are dismembered or partially consumed by ants or ground beetles that sometimes feed on them in the traps. Because misidentification can have expensive consequences, a molecular diagnostic tool would be of great value to eradication managers. We demonstrate that a cocktail of three primer pairs in a single polymerase chain reaction (PCR) amplify species-specific microsatellites that unambiguously distinguish the boll weevil from three other weevil species tested, including pepper weevil; cranberry weevil, Anthonomus eugenii musculus Say; and pecan weevil, Curculio caryae Horn. However, it does not distinguish the boll weevil from the subspecific "thurberia" weevil. A universal internal transcribed spacer primer pair included in the cocktail cross-amplifies DNA from all species, serving as a positive control. Furthermore, the diagnostic primers amplified the target microsatellites from various boll weevil adult body parts, indicating that the PCR technology using the primer cocktail is sensitive enough to positively identify a boll weevil even when the body is partly degraded.

  9. Advantages and disadvantages of current diagnostic tests for the detection of Helicobacter pylori.

    Science.gov (United States)

    Mégraud, F

    1996-01-01

    Current tests used to detect Helicobacter pylori are either invasive (histological detection, culture, the polymerase chain reaction (PCR), smear examination) or non-invasive (serology, 13C-urea breath test). These tests vary in their sensitivity and specificity, and the choice of test will depend on the situation, for example, whether the test is to detect infection or the success of eradication treatment. The accuracy of histological tests depends, to a large degree, on the expertise of the pathologist, while the accuracy of culture can depend on the conditions in which the specimen is transported and processed. When performed under optimal conditions, both techniques give very good results. The PCR test has similar sensitivity and specificity to histological and culture tests but a strict protocol must be followed to avoid contamination with H. pylori DNA. The rapid urease test (with a reading taken 1 hour later) is suitable for diagnosis before treatment but its sensitivity decreases after treatment. Smear examination has limited sensitivity. The urea breath test and serology (specific IgG detected by enzyme-linked immunosorbent assay with purified antigens) have sensitivities close to those using the best of the biopsy methods. Other points to consider when selecting a test are its availability, the rapidity of the results (which can range from a few minutes to 2 weeks), possibilities for retrospective analysis, quantification and the detection of pathogenic properties, the globality of certain tests that present an overall picture of the stomach, thus avoiding errors in sampling, and the cost of the test. Important added value can be gained from certain tests: histology allows evaluation of the status of the mucosa, culture allows strain typing and tests for antibiotic susceptibility, and the breath test can confirm successful eradication without endoscopy. When the diagnostic tests are performed correctly, most of them are highly accurate.

  10. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  11. Accuracy of Triple Diagnostic Test in Patients with Thyroid Nodule at Dr. Cipto Mangunkusumo General Hospital

    Directory of Open Access Journals (Sweden)

    Diani Kartini

    2017-04-01

    Full Text Available The aim of the study is to evaluate the accuracy of triple diagnostic test on thyroid nodules. The data from patients’ medical records who came to Cipto Mangunkusumo General Hospital for the first time or for evaluation of thyroid nodule and patients who underwent thyroidectomy during 2010 to 2011. Clinical examination was scored by McGill Thyroid Nodule Score. ROC procedure was performed to obtain clinical cut-off scores of diagnosis of malignant. Ultrasonography (USG result was considered malignant for TIRADS 4, 5, and 6. If clinical, USG and histopathology examinations of triple diagnostic give positive results, it will be classified as concordant malignant whereas if all those three show benign results, the classification is benign. Thyroid carcinoma was found in 134 out of 161 patients with thyroid nodule. There were 84 patients with concordant results for all three elements of the triple test. Out of 84 patients with concordant triple diagnostic results, there were 53 malignant cases (32.9% and 31 benign cases (19.3%. Main histopathological findings among patients with thyroid carcinoma was papillary (90.3%, follicular (3%, medullary (0.7%, and anaplastic (6%. The sensitivity and specificity of triple diagnostic was 77% and 94%, with positive predictive value of 98%, negative predictive value of 51,6% and accuracy of 80.9%. Combination of clinical findings, USG, and FNAB gave malignant probability of 92%, better than combination of clinical findings and USG (81.6% or clinical findings and FNAB (87%. Triple diagnostic cannot be used as an ideal test to replace frozen section examination in managing thyroid nodule. However, in cases with concordant results of each triple diagnostic’s element, the positive predictive value (98% and malignant probability (92% is high. Keywords: thyroid nodule, triple diagnostic, accuracy.   Akurasi Metode Triple Diagnostic pada Pasien Nodul Tiroid  di RSUPN Dr. Cipto Mangunkusumo   Abstrak Tujuan

  12. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  13. The glucose breath test: a diagnostic test for small bowel stricture(s) in Crohn's disease.

    Science.gov (United States)

    Mishkin, Daniel; Boston, Francis M; Blank, David; Yalovsky, Morty; Mishkin, Seymour

    2002-03-01

    The aim of this study was to determine whether an indirect noninvasive indicator of proximal bacterial overgrowth, the glucose breath test, was of diagnostic value in inflammatory bowel disease. Twenty four of 71 Crohn's disease patients tested had a positive glucose breath test. No statistical conclusions could be drawn between the Crohn's disease activity index and glucose breath test status. Of patients with radiologic evidence of small bowel stricture(s), 96.0% had a positive glucose breath test, while only one of 46 negative glucose breath test patients had a stricture. The positive and negative predictive values for a positive glucose breath test as an indicator of stricture formation were 96.0% and 97.8%, respectively. This correlation was not altered in Crohn's disease patients with fistulae or status postresection of the terminal ileum. The data in ulcerative colitis were nondiagnostic. In conclusion, the glucose breath test appears to be an accurate noninvasive inexpensive diagnostic test for small bowel stricture(s) and secondary bacterial overgrowth in Crohn's disease.

  14. Task specificity of finger dexterity tests

    NARCIS (Netherlands)

    Berger, M.A.M.; Krul, A.; Daanen, H.A.M.

    2009-01-01

    Finger dexterity tests are generally used to assess performance decrease due to gloves, cold and pathology. It is generally assumed that the O’Connor and Purdue Pegboard test yield similar results. In this experiment we compared these two tests for dry conditions without gloves, and for dry and wet

  15. Task specificity of finger dexterity tests

    NARCIS (Netherlands)

    Berger, M.A.M.; Krul, A.J.; Daanen, H.A.M.

    2009-01-01

    Finger dexterity tests are generally used to assess performance decrease due to gloves, cold and pathology. It is generally assumed that the O'Connor and Purdue Pegboard test yield similar results. In this experiment we compared these two tests for dry conditions without gloves, and for dry and wet

  16. Irregular analytical errors in diagnostic testing - a novel concept.

    Science.gov (United States)

    Vogeser, Michael; Seger, Christoph

    2018-02-23

    In laboratory medicine, routine periodic analyses for internal and external quality control measurements interpreted by statistical methods are mandatory for batch clearance. Data analysis of these process-oriented measurements allows for insight into random analytical variation and systematic calibration bias over time. However, in such a setting, any individual sample is not under individual quality control. The quality control measurements act only at the batch level. Quantitative or qualitative data derived for many effects and interferences associated with an individual diagnostic sample can compromise any analyte. It is obvious that a process for a quality-control-sample-based approach of quality assurance is not sensitive to such errors. To address the potential causes and nature of such analytical interference in individual samples more systematically, we suggest the introduction of a new term called the irregular (individual) analytical error. Practically, this term can be applied in any analytical assay that is traceable to a reference measurement system. For an individual sample an irregular analytical error is defined as an inaccuracy (which is the deviation from a reference measurement procedure result) of a test result that is so high it cannot be explained by measurement uncertainty of the utilized routine assay operating within the accepted limitations of the associated process quality control measurements. The deviation can be defined as the linear combination of the process measurement uncertainty and the method bias for the reference measurement system. Such errors should be coined irregular analytical errors of the individual sample. The measurement result is compromised either by an irregular effect associated with the individual composition (matrix) of the sample or an individual single sample associated processing error in the analytical process. Currently, the availability of reference measurement procedures is still highly limited, but LC

  17. Surface enhanced Raman spectroscopy (SERS) for in vitro diagnostic testing at the point of care

    Science.gov (United States)

    Marks, Haley; Schechinger, Monika; Garza, Javier; Locke, Andrea; Coté, Gerard

    2017-06-01

    Point-of-care (POC) device development is a growing field that aims to develop low-cost, rapid, sensitive in-vitro diagnostic testing platforms that are portable, self-contained, and can be used anywhere - from modern clinics to remote and low resource areas. In this review, surface enhanced Raman spectroscopy (SERS) is discussed as a solution to facilitating the translation of bioanalytical sensing to the POC. The potential for SERS to meet the widely accepted "ASSURED" (Affordable, Sensitive, Specific, User-friendly, Rapid, Equipment-free, and Deliverable) criterion provided by the World Health Organization is discussed based on recent advances in SERS in vitro assay development. As SERS provides attractive characteristics for multiplexed sensing at low concentration limits with a high degree of specificity, it holds great promise for enhancing current efforts in rapid diagnostic testing. In outlining the progression of SERS techniques over the past years combined with recent developments in smart nanomaterials, high-throughput microfluidics, and low-cost paper diagnostics, an extensive number of new possibilities show potential for translating SERS biosensors to the POC.

  18. Surface enhanced Raman spectroscopy (SERS for in vitro diagnostic testing at the point of care

    Directory of Open Access Journals (Sweden)

    Marks Haley

    2017-06-01

    Full Text Available Point-of-care (POC device development is a growing field that aims to develop low-cost, rapid, sensitive in-vitro diagnostic testing platforms that are portable, self-contained, and can be used anywhere – from modern clinics to remote and low resource areas. In this review, surface enhanced Raman spectroscopy (SERS is discussed as a solution to facilitating the translation of bioanalytical sensing to the POC. The potential for SERS to meet the widely accepted “ASSURED” (Affordable, Sensitive, Specific, User-friendly, Rapid, Equipment-free, and Deliverable criterion provided by the World Health Organization is discussed based on recent advances in SERS in vitro assay development. As SERS provides attractive characteristics for multiplexed sensing at low concentration limits with a high degree of specificity, it holds great promise for enhancing current efforts in rapid diagnostic testing. In outlining the progression of SERS techniques over the past years combined with recent developments in smart nanomaterials, high-throughput microfluidics, and low-cost paper diagnostics, an extensive number of new possibilities show potential for translating SERS biosensors to the POC.

  19. Continuous-data diagnostic tests for paratuberculosis as a multistage disease

    DEFF Research Database (Denmark)

    Toft, Nils; Nielsen, Søren Saxmose; Jørgensen, Erik

    2005-01-01

    We devised a general method for interpretation of multistage diseases using continuous-data diagnostic tests. As an example, we used paratuberculosis as a multistage infection with 2 stages of infection as well as a noninfected state. Using data from a Danish research project, a fecal culture...... testing scheme was linked to an indirect ELISA and adjusted for covariates (parity, age at first calving, and days in milk). We used the log-transformed optical densities in a Bayesian network to obtain the probabilities for each of the 3 infection stages for a given optical density (adjusted...... for covariates). The strength of this approach was that the uncertainty associated with a test was imposed directly on the individual test result rather than aggregated into the population-based measures of test properties (i.e., sensitivity and specificity)...

  20. Non-IgE-related diagnostic methods (LST, patch test).

    Science.gov (United States)

    Matsumoto, Kenji

    2015-01-01

    Although most food allergy patients have immediate-type reactions, some have delayed-type reactions. Unlike for the detection of food-specific IgE antibody in immediate-type (IgE-mediated) food allergies, only a few tests are currently available to aid in the diagnosis of delayed-type (non-IgE-mediated) food allergies. This chapter summarizes our current understanding of one in vitro test and one in vivo test for non-IgE-mediated food allergies: the lymphocyte stimulation test (LST) and the atopy patch test (APT). Although the LST is not yet standardized, a food protein-specific LST might be a useful tool for diagnosing delayed-type food allergies, and especially those manifesting with gastrointestinal symptoms but not skin symptoms. Various remaining issues - including basophil contamination of the peripheral blood mononuclear cell fraction and lipopolysaccharide contamination of food antigen preparations - are also discussed. The APT uses an epicutaneous patch technique to occlusively apply food antigens to the skin to induce inflammatory reactions at the patch application site. Because the APT shows modest sensitivity and specificity, the clinical benefit of the APT in the diagnosis of food allergies in patients with atopic dermatitis is limited. A position paper on the APT issued by the European Academy of Allergy and Clinical Immunology/Global Allergy and Asthma European Network in 2006 is briefly summarized, and several recent APT-related topics, including APT use for the diagnosis of food protein-induced enterocolitis syndrome, are discussed. © 2015 S. Karger AG, Basel.

  1. Diagnostic evaluation of rapid tests for scrub typhus in the Indian population is needed.

    Science.gov (United States)

    Shivalli, Siddharudha

    2016-05-12

    Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is being described as a re-emerging infectious disease in India. Differentiating scrub typhus from other endemic diseases like malaria, leptospirosis, dengue fever, typhoid, etc. is difficult due to overlapping clinical features and a lower positivity for eschars in Asian populations. Hence, the diagnosis heavily relies on laboratory tests. Costs and the need of technical expertise limit the wide use of indirect immunoperoxidase or immunofluorescence assays, ELISA and PCR. The Weil-Felix test is the most commonly used and least expensive serological test, but lacks both sensitivity and specificity. Hence, the diagnosis of scrub typhus is often delayed or overlooked. With due consideration of the cost, rapidity, single test result and simplicity of interpretation, rapid diagnostic tests have come into vogue. However, evaluation of rapid diagnostic tests for scrub typhus in the Indian population is needed to justify or discourage their use. Research studies are needed to find the most suitable test in terms of the rapidity of the result, simplicity of the procedure, ease of interpretation and cost to be used in the Indian populace.

  2. Development, characterization and diagnostic application of a monoclonal antibody specific for a proteinase K resistant Lawsonia intracellularis antigen

    DEFF Research Database (Denmark)

    Boesen, Henriette T.; Jensen, Tim Kåre; Jungersen, Gregers

    2005-01-01

    Proliferative enteropathy (PE) is one of the most important infections in pigs caused by Lawsonia intracellularis, an obligate intracellular bacterium. The purpose of the present investigation was to develop monoclonal antibodies with specificity to L. intracellularis useful both for diagnostic...... (mAb), Law1-DK, isotyped as IgG2b was selected by indirect immunofluorescence antibody test (IFAT). Histological sections of the intestines from pigs affected by proliferative enteropathy and in vitro grown bacteria in cell culture were tested positive for the presence of L. intracellularis...

  3. The meaning of diagnostic test results: A spreadsheet for swift data analysis

    International Nuclear Information System (INIS)

    MacEneaney, Peter M.; Malone, Dermot E.

    2000-01-01

    AIMS: To design a spreadsheet program to: (a) analyse rapidly diagnostic test result data produced in local research or reported in the literature; (b) correct reported predictive values for disease prevalence in any population; (c) estimate the post-test probability of disease in individual patients. MATERIALS AND METHODS: Microsoft Excel TM was used. Section A: a contingency (2 x 2) table was incorporated into the spreadsheet. Formulae for standard calculations [sample size, disease prevalence, sensitivity and specificity with 95% confidence intervals, predictive values and likelihood ratios (LRs)] were linked to this table. The results change automatically when the data in the true or false negative and positive cells are changed. Section B: this estimates predictive values in any population, compensating for altered disease prevalence. Sections C-F: Bayes' theorem was incorporated to generate individual post-test probabilities. The spreadsheet generates 95% confidence intervals, LRs and a table and graph of conditional probabilities once the sensitivity and specificity of the test are entered. The latter shows the expected post-test probability of disease for any pre-test probability when a test of known sensitivity and specificity is positive or negative. RESULTS: This spreadsheet can be used on desktop and palmtop computers. The MS Excel TM version can be downloaded via the Internet from the URL ftp://radiography.com/pub/Rad-data99.xls CONCLUSION: A spreadsheet is useful for contingency table data analysis and assessment of the clinical meaning of diagnostic test results. MacEneaney, P.M., Malone, D.E. (2000)

  4. Wavenumber selection based analysis in Raman spectroscopy improves skin cancer diagnostic specificity at high sensitivity levels (Conference Presentation)

    Science.gov (United States)

    Zhao, Jianhua; Zeng, Haishan; Kalia, Sunil; Lui, Harvey

    2017-02-01

    Background: Raman spectroscopy is a non-invasive optical technique which can measure molecular vibrational modes within tissue. A large-scale clinical study (n = 518) has demonstrated that real-time Raman spectroscopy could distinguish malignant from benign skin lesions with good diagnostic accuracy; this was validated by a follow-up independent study (n = 127). Objective: Most of the previous diagnostic algorithms have typically been based on analyzing the full band of the Raman spectra, either in the fingerprint or high wavenumber regions. Our objective in this presentation is to explore wavenumber selection based analysis in Raman spectroscopy for skin cancer diagnosis. Methods: A wavenumber selection algorithm was implemented using variably-sized wavenumber windows, which were determined by the correlation coefficient between wavenumbers. Wavenumber windows were chosen based on accumulated frequency from leave-one-out cross-validated stepwise regression or least and shrinkage selection operator (LASSO). The diagnostic algorithms were then generated from the selected wavenumber windows using multivariate statistical analyses, including principal component and general discriminant analysis (PC-GDA) and partial least squares (PLS). A total cohort of 645 confirmed lesions from 573 patients encompassing skin cancers, precancers and benign skin lesions were included. Lesion measurements were divided into training cohort (n = 518) and testing cohort (n = 127) according to the measurement time. Result: The area under the receiver operating characteristic curve (ROC) improved from 0.861-0.891 to 0.891-0.911 and the diagnostic specificity for sensitivity levels of 0.99-0.90 increased respectively from 0.17-0.65 to 0.20-0.75 by selecting specific wavenumber windows for analysis. Conclusion: Wavenumber selection based analysis in Raman spectroscopy improves skin cancer diagnostic specificity at high sensitivity levels.

  5. HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites

    Science.gov (United States)

    Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Fransen, Katrien; Page, Anne-Laure

    2017-01-01

    Abstract Introduction: We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. Methods: In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Results: Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. Conclusions: The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy. PMID:28691437

  6. Recent advances in diagnostic testing for gastroesophageal reflux disease.

    Science.gov (United States)

    Naik, Rishi D; Vaezi, Michael F

    2017-06-01

    Gastroesophageal reflux disease (GERD) has a large economic burden with important complications that include esophagitis, Barrett's esophagus, and adenocarcinoma. Despite endoscopy, validated patient questionnaires, and traditional ambulatory pH monitoring, the diagnosis of GERD continues to be challenging. Areas covered: This review will explore the difficulties in diagnosing GERD with a focus on new developments, ranging from basic fundamental changes (histology and immunohistochemistry) to direct patient care (narrow-band imaging, impedance, and response to anti-reflux surgery). We searched PubMed using the noted keywords. We included data from full-text articles published in English. Further relevant articles were identified from the reference lists of review articles. Expert commentary: Important advances in novel parameters in intraluminal impedance monitoring such as baseline impedance monitoring has created some insight into alternative diagnostic strategies in GERD. Recent advances in endoscopic assessment of esophageal epithelial integrity via mucosal impedance measurement is questioning the paradigm of prolonged ambulatory testing for GERD. The future of reflux diagnosis may very well be without the need for currently employed technologies and could be as simple as assessing changes in epithelia integrity as a surrogate marker for GERD. However, future studies must validate such an approach.

  7. Spatial resolution test of a beam diagnostic system for DESIREE

    Science.gov (United States)

    Das, Susanta; Kallberg, A.

    2010-11-01

    A diagnostic system based on the observation of low energy ( ˜ 10 eV) secondary electrons (SE) produced by a beam, striking a metallic foil has been built to monitor and to cover the wide range of beam intensities and energies for Double ElectroStatic Ion Ring ExpEriment [1,2].The system consists of a Faraday cup to measure the beam current, a collimator with circular apertures of different diameters to measure the spatial resolution of the system, a beam profile monitoring system (BPMS), and a control unit. The BPMS, in turn, consists of an aluminim (Al) foil, a grid placed in front of the Al foil to accelerate the SE, position sensitive MCP, fluorescent screen, and a CCD camera to capture the images. The collimator contains a set of circular holes of different diameters and separations (d) between them. The collimator cuts out from the beam areas equal to the holes with separation d mm between the beams centers and creates well separated (distinguishable) narrow beams of approximately same intensity close to each other. A 10 keV proton beam was used. The spatial resolution of the system was tested for different Al plate and MCP voltages and resolution of better than 2 mm was achieved. Ref.: 1. K. Kruglov {et al}., NIM A 441 (2000) 595; 701 (2002) 193c, 2. MSL and Atomic Physics, Stockholm Univ.(www.msl.se, http://www.atom.physto.se/Cederquist/desiree/web/hc.html).

  8. Diagnostic Accuracy of 3 Physical Examination Tests in the Assessment of Hip Microinstability.

    Science.gov (United States)

    Hoppe, Daniel J; Truntzer, Jeremy N; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc R

    2017-11-01

    Hip microinstability is a diagnosis gaining increasing interest. Physical examination tests to identify microinstability have not been objectively investigated using intraoperative confirmation of instability as a reference standard. To determine the test characteristics and diagnostic accuracy of 3 physical examination maneuvers in the detection of hip microinstability. Cohort study (diagnosis); Level of evidence, 2. A review was conducted of 194 consecutive hip arthroscopic procedures performed by a sports medicine surgeon at a tertiary-care academic center. Physical examination findings of interest, including the abduction-hyperextension-external rotation (AB-HEER) test, the prone instability test, and the hyperextension-external rotation (HEER) test, were obtained from prospectively collected data. The reference standard was intraoperative identification of instability based on previously published objective criteria. Test characteristics, including sensitivity, specificity, positive and negative predictive values, and accuracy, were calculated for each test as well as for combinations of tests. A total of 109 patients were included in the analysis. The AB-HEER test was most accurate, with a sensitivity of 80.6% (95% CI, 70.8%-90.5%) and a specificity of 89.4% (95% CI, 80.5%-98.2%). The prone instability test had a low sensitivity (33.9%) but a very high specificity (97.9%). The HEER test performed second in both sensitivity (71.0%) and specificity (85.1%). The combination of multiple tests with positive findings did not yield significantly greater accuracy. All tests had high positive predictive values (range, 86.3%-95.5%) and moderate negative predictive values (range, 52.9%-77.8%). When all 3 tests had positive findings, there was a 95.0% (95% CI, 90.1%-99.9%) chance that the patient had microinstability. The AB-HEER test most accurately predicted hip instability, followed by the HEER test and the prone instability test. However, the high specificity of the

  9. Chemical cleaning specification: few tube test model

    International Nuclear Information System (INIS)

    Hampton, L.V.; Simpson, J.L.

    1979-09-01

    The specification is for the waterside chemical cleaning of the 2 1/4 Cr - 1 Mo steel steam generator tubes. It describes the reagents and conditions for post-chemical cleaning passivation of the evaporator tubes

  10. Interlaboratory diagnostic accuracy of a Salmonella specific PCR-based method

    DEFF Research Database (Denmark)

    Malorny, B.; Hoorfar, Jeffrey; Hugas, M.

    2003-01-01

    A collaborative study involving four European laboratories was conducted to investigate the diagnostic accuracy of a Salmonella specific PCR-based method, which was evaluated within the European FOOD-PCR project (http://www.pcr.dk). Each laboratory analysed by the PCR a set of independent obtained...... presumably naturally contaminated samples and compared the results with the microbiological culture method. The PCR-based method comprised a preenrichment step in buffered peptone water followed by a thermal cell lysis using a closed tube resin-based method. Artificially contaminated minced beef and whole......-based diagnostic methods and is currently proposed as international standard document....

  11. [Diagnostic value of neuropsychological tests in mild cognitive impairment comorbid with Parkinson's disease].

    Science.gov (United States)

    Laskowska, Ilona; Koczorowski, Andrzej; Koziorowski, Dariusz; Gawryś, Ludwika

    2014-01-01

    Mild cognitive impairment (MCI) is present in on average one-fourth of Parkinson's disease (PD) patients with no dementia diagnosis. Only recently has PD-MCI been treated as a new diagnostic entity. In 2012, unified criteria were adopted which allow both diagnosing MCI in Parkinson's disease (PD-MCI) and further classification taking into account the profile of cognitive dysfunctions and the probability of evolution towards dementia. The diagnostic criteria were presented in the form of stipulations and guidelines assuming that diagnostic process is based on the neuropsychological assessment of the patient. The notion of MCI had been borrowed and for a couple of years had been relying on definitions developed in relation to Alzheimer's disease. For the first time, in the proposed criteria memory dysfunction is not the basis of classification. Only two categories of dysfunctions have been retained, single-domain and multiple-domain. Whether the adopted criteria will contribute to an accurate diagnosis of cognitive dysfunctions and PD-specific dementing processes remains an open question. In spite of some limitations, the presented criteria can certainly improve the efficacy of monitoring the patient's state at the same time allowing the hope for an appropriate therapy and a higher quality of life. Moreover, the unification of diagnostic criteria will be crucial in assessing usefulness ofneuropsychological test instruments as a basic method of investigating neurodegenerative processes not only in PD.

  12. A hybrid model for combining case-control and cohort studies in systematic reviews of diagnostic tests

    Science.gov (United States)

    Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao

    2014-01-01

    Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179

  13. Using recruitment source timing and diagnosticity to enhance applicants' occupation-specific human capital.

    Science.gov (United States)

    Campion, Michael C; Ployhart, Robert E; Campion, Michael A

    2017-05-01

    [Correction Notice: An Erratum for this article was reported in Vol 102(5) of Journal of Applied Psychology (see record 2017-14296-001). In the article, the following headings were inadvertently set at the wrong level: Method, Participants and Procedure, Measures, Occupation specific human capital, Symbolic jobs, Relevant majors, Occupation-specific capital hotspots, Source timing, Source diagnosticity, Results, and Discussion. All versions of this article have been corrected.] This study proposes that reaching applicants through more diagnostic recruitment sources earlier in their educational development (e.g., in high school) can lead them to invest more in their occupation-specific human capital (OSHC), thereby making them higher quality candidates. Using a sample of 78,157 applicants applying for jobs within a desirable professional occupation in the public sector, results indicate that applicants who report hearing about the occupation earlier, and applicants who report hearing about the occupation through more diagnostic sources, have higher levels of OSHC upon application. Additionally, source timing and diagnosticity affect the likelihood of candidates applying for jobs symbolic of the occupation, selecting relevant majors, and attending educational institutions with top programs related to the occupation. These findings suggest a firm's recruiting efforts may influence applicants' OSHC investment strategies. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  14. Diagnostic testing for celiac disease among patients with abdominal symptoms: a systematic review.

    Science.gov (United States)

    van der Windt, Daniëlle A W M; Jellema, Petra; Mulder, Chris J; Kneepkens, C M Frank; van der Horst, Henriëtte E

    2010-05-05

    The symptoms and consequences of celiac disease usually resolve with a lifelong gluten-free diet. However, clinical presentation is variable and most patients presenting with abdominal symptoms in primary care will not have celiac disease and unnecessary diagnostic testing should be avoided. To summarize evidence on the performance of diagnostic tests for identifying celiac disease in adults presenting with abdominal symptoms in primary care or similar settings. A literature search via MEDLINE (beginning in January 1966) and EMBASE (beginning in January 1947) through December 2009 and a manual search of references for additional relevant studies. Diagnostic studies were selected if they had a cohort or nested case-control design, enrolled adults presenting with nonacute abdominal symptoms, the prevalence of celiac disease was 15% or less, and the tests used included gastrointestinal symptoms or serum antibody tests. Quality assessment using the Quality Assessment of Diagnostic Accuracy Studies tool and data extraction were performed by 2 reviewers independently. Sensitivities and specificities were calculated for each study and pooled estimates were computed using bivariate analysis if there was clinical and statistical homogeneity. Sixteen studies were included in the review (N = 6085 patients). The performance of abdominal symptoms varied widely. The sensitivity of diarrhea, for example, ranged from 0.27 to 0.86 and specificity from 0.21 to 0.86. Pooled estimates for IgA antiendomysial antibodies (8 studies) were 0.90 (95% confidence interval [CI], 0.80-0.95) for sensitivity and 0.99 (95% CI, 0.98-1.00) for specificity (positive likelihood ratio [LR] of 171 and negative LR of 0.11). Pooled estimates for IgA antitissue transglutaminase antibodies (7 studies) were 0.89 (95% CI, 0.82-0.94) and 0.98 (95% CI, 0.95-0.99), respectively (positive LR of 37.7 and negative LR of 0.11). The IgA and IgG antigliadin antibodies showed variable results, especially for

  15. Development and assessment of molecular diagnostic tests for 15 enteropathogens causing childhood diarrhoea: a multicentre study.

    Science.gov (United States)

    Liu, Jie; Kabir, Furqan; Manneh, Jainaba; Lertsethtakarn, Paphavee; Begum, Sharmin; Gratz, Jean; Becker, Steve M; Operario, Darwin J; Taniuchi, Mami; Janaki, Lalitha; Platts-Mills, James A; Haverstick, Doris M; Kabir, Mamun; Sobuz, Shihab U; Nakjarung, Kaewkanya; Sakpaisal, Pimmada; Silapong, Sasikorn; Bodhidatta, Ladaporn; Qureshi, Shahida; Kalam, Adil; Saidi, Queen; Swai, Ndealilia; Mujaga, Buliga; Maro, Athanasia; Kwambana, Brenda; Dione, Michel; Antonio, Martin; Kibiki, Gibson; Mason, Carl J; Haque, Rashidul; Iqbal, Najeeha; Zaidi, Anita K M; Houpt, Eric R

    2014-08-01

    Childhood diarrhoea can be caused by many pathogens that are difficult to assay in the laboratory. Molecular diagnostic techniques provide a uniform method to detect and quantify candidate enteropathogens. We aimed to develop and assess molecular tests for identification of enteropathogens and their association with disease. We developed and assessed molecular diagnostic tests for 15 enteropathogens across three platforms-PCR-Luminex, multiplex real-time PCR, and TaqMan array card-at five laboratories worldwide. We judged the analytical and clinical performance of these molecular techniques against comparator methods (bacterial culture, ELISA, and PCR) using 867 diarrhoeal and 619 non-diarrhoeal stool specimens. We also measured molecular quantities of pathogens to predict the association with diarrhoea, by univariate logistic regression analysis. The molecular tests showed very good analytical and clinical performance at all five laboratories. Comparator methods had limited sensitivity compared with the molecular techniques (20-85% depending on the target) but good specificity (median 97·3%, IQR 96·5-98·9; mean 95·2%, SD 9·1). Positive samples by comparator methods usually had higher molecular quantities of pathogens than did negative samples, across almost all platforms and for most pathogens (pMolecular diagnostic tests can be implemented successfully and with fidelity across laboratories around the world. In the case of diarrhoea, these techniques can detect pathogens with high sensitivity and ascribe diarrhoeal associations based on quantification, including in mixed infections, providing rich and unprecedented measurements of infectious causes. Bill & Melinda Gates Foundation Next Generation Molecular Diagnostics Project. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Diagnostic test accuracy of nutritional tools used to identify undernutrition in patients with colorectal cancer: a systematic review.

    Science.gov (United States)

    Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela

    2015-05-15

    Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive

  17. Sputum smear negative pulmonary tuberculosis: sensitivity and specificity of diagnostic algorithm

    Directory of Open Access Journals (Sweden)

    Mugusi Ferdinand M

    2011-11-01

    Full Text Available Abstract Background The diagnosis of pulmonary tuberculosis in patients with Human Immunodeficiency Virus (HIV is complicated by the increased presence of sputum smear negative tuberculosis. Diagnosis of smear negative pulmonary tuberculosis is made by an algorithm recommended by the National Tuberculosis and Leprosy Programme that uses symptoms, signs and laboratory results. The objective of this study is to determine the sensitivity and specificity of the tuberculosis treatment algorithm used for the diagnosis of sputum smear negative pulmonary tuberculosis. Methods A cross-section study with prospective enrollment of patients was conducted in Dar-es-Salaam Tanzania. For patients with sputum smear negative, sputum was sent for culture. All consenting recruited patients were counseled and tested for HIV. Patients were evaluated using the National Tuberculosis and Leprosy Programme guidelines and those fulfilling the criteria of having active pulmonary tuberculosis were started on anti tuberculosis therapy. Remaining patients were provided appropriate therapy. A chest X-ray, mantoux test, and Full Blood Picture were done for each patient. The sensitivity and specificity of the recommended algorithm was calculated. Predictors of sputum culture positive were determined using multivariate analysis. Results During the study, 467 subjects were enrolled. Of those, 318 (68.1% were HIV positive, 127 (27.2% had sputum culture positive for Mycobacteria Tuberculosis, of whom 66 (51.9% were correctly treated with anti-Tuberculosis drugs and 61 (48.1% were missed and did not get anti-Tuberculosis drugs. Of the 286 subjects with sputum culture negative, 107 (37.4% were incorrectly treated with anti-Tuberculosis drugs. The diagnostic algorithm for smear negative pulmonary tuberculosis had a sensitivity and specificity of 38.1% and 74.5% respectively. The presence of a dry cough, a high respiratory rate, a low eosinophil count, a mixed type of anaemia and

  18. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  19. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  20. Confirmatory Tests for the Diagnosis of Primary Aldosteronism: A Prospective Diagnostic Accuracy Study.

    Science.gov (United States)

    Song, Ying; Yang, Shumin; He, Wenwen; Hu, Jinbo; Cheng, Qingfeng; Wang, Yue; Luo, Ting; Ma, Linqiang; Zhen, Qianna; Zhang, Suhua; Mei, Mei; Wang, Zhihong; Qing, Hua; Bruemmer, Dennis; Peng, Bin; Li, Qifu

    2018-01-01

    The diagnosis of primary aldosteronism typically requires at least one confirmatory test. The fludrocortisone suppression test is generally accepted as a reliable confirmatory test, but it is cumbersome. Evidence from accuracy studies of the saline infusion test (SIT) and the captopril challenge test (CCT) has provided conflicting results. This prospective study aimed to evaluate the diagnostic accuracy of the SIT and CCT using fludrocortisone suppression test as the reference standard. One hundred thirty-five patients diagnosed with primary aldosteronism and 101 patients diagnosed with essential hypertension who completed the 3 confirmatory tests were included for the diagnostic accuracy analysis. The areas under the receiver-operator characteristics curves of the CCT and SIT were 0.96 (95% confidence interval [CI], 0.92-0.98) and 0.96 (95% CI, 0.92-0.98), respectively, using post-test plasma aldosterone concentration (PAC) for diagnosis. However, the areas under the receiver-operator characteristics curves of the CCT decreased to 0.71 (95% CI, 0.65-0.77) when the PAC suppression percentage was used to diagnose primary aldosteronism. The optimal cutoff of PAC post-CCT was set at 11 ng/dL, resulting in a sensitivity of 0.90 (95% CI, 0.84-0.95) and a specificity of 0.90 (95% CI, 0.83-0.95), which were not significantly different from those of SIT (with PAC post-SIT set at 8 ng/dL, sensitivity: 0.85 [95% CI, 0.78-0.91], P =0.192; specificity: 0.92 [95% CI, 0.85-0.97], P =0.551). In conclusion, both CCT and SIT are accurate alternatives to the more complex fludrocortisone suppression test. Because CCT is safe and much easier to perform, it may serve as a more feasible alternative. When interpreting the results of CCT, PAC post-CCT is highly recommended. © 2017 American Heart Association, Inc.

  1. [Diagnostic capacity of skin prick test in egg and cow's milk allergic infants].

    Science.gov (United States)

    Yan, Jun-mei; Chen, Jing; Li, Hai-qi; Hu, Yan

    2011-05-01

    Mean diameter is the most common used parameter for wheal response assessment after skin prick test. This study aimed to investigate the diagnostic capacity of mean diameter according to the outcome of oral food challenge, and to determine the cut-off points that could render food challenges unnecessary. Data of 173 children referred to the Division of Primary Child Health Care for the evaluation of suspected food allergy were prospectively studied. All children underwent skin prick test and open food challenge to the relevant food(s) in clinic. The mean wheal diameter of skin prick test was measured, and open food challenge was performed to confirm food allergy. The SPSS software package version 13.0 for windows (SPSS, Chicago, IL, USA) was used for all statistical analysis. Open food challenge was taken as the gold standard for diagnosis. Diagnostic capacity of skin prick test, including the sensitivity, specificity, positive predictive value, negative predictive value, was calculated by cross-table. In addition, receiver operating characteristic curve (ROC) was plotted and area under the curve (AUC) was calculated to quantify the accuracy of the parameter. For the 173 children, 271 open food challenges were performed with egg white, egg yolk and cow's milk, In which 123 were positive, 99 children were diagnosed as food allergy. Cutaneous symptoms (87.0%) were most common, followed by gastrointestinal symptoms (9.8%). The AUC of mean diameter was 0.794 for egg white, 0.804 for egg yolk and 0.904 for cow's milk. The sensitivity of skin prick test with a cut-off value of ≥ 3 mm was ranged from 71% to 87%, while the specificity was between 31% and 57%. The authors also defined food specific skin prick test mean diameters that were 100% diagnostic for allergy to egg white (≥ 8.5 mm), egg yolk (≥ 5.5 mm), cow's milk (≥ 5.5 mm). Predictive decision points for a positive outcome of food challenges can be calculated for egg and cow's milk using mean diameter. It

  2. Laboratory evaluation of three dual rapid diagnostic tests for HIV and syphilis in China and Nigeria.

    Science.gov (United States)

    Yin, Yue-Ping; Ngige, Evelyn; Anyaike, Chukwuma; Ijaodola, Gbenga; Oyelade, Taiwo A; Vaz, Rui Gama; Newman, Lori M; Chen, Xiang-Sheng

    2015-06-01

    To determine the laboratory-based performance and operational characteristics of three dual rapid diagnostic tests (RDTs) for testing HIV and syphilis. Three dual RDTs (SD Bioline, Chembio, and MedMira) were evaluated using 1514 serum specimens archived at laboratories or collected from clinics in China and Nigeria to determine sensitivity and specificity, with 95% confidence intervals. Concordance of testing results read by two technicians, stability of testing results read at two time points, and test operation characteristics were also assessed. All three of the evaluated RDTs gave excellent performance with a combined sensitivity ranging from 99.0%-99.6% for HIV and 98.3%-99.0% for syphilis, and a combined specificity ranging from 97.9%-99.0% for HIV and 97.2%-99.6% for syphilis. Concordance of testing results between two technicians and stability of testing results read within and one hour past the recommended reading period showed excellent agreement, with Kappa greater than or equal to 0.98. All the tests were found to be very or fairly easy to use and easy to interpret the results. Further evaluations of these dual RDTs with whole blood in field settings, and more studies on the implication of introduction of these tests in HIV and syphilis control programs are needed. Copyright © 2015. Published by Elsevier Ireland Ltd.

  3. A stochastic model to determine the economic value of changing diagnostic test characteristics for identification of cattle for treatment of bovine respiratory disease.

    Science.gov (United States)

    Theurer, M E; White, B J; Larson, R L; Schroeder, T C

    2015-03-01

    Bovine respiratory disease is an economically important syndrome in the beef industry, and diagnostic accuracy is important for optimal disease management. The objective of this study was to determine whether improving diagnostic sensitivity or specificity was of greater economic value at varied levels of respiratory disease prevalence by using Monte Carlo simulation. Existing literature was used to populate model distributions of published sensitivity, specificity, and performance (ADG, carcass weight, yield grade, quality grade, and mortality risk) differences among calves based on clinical respiratory disease status. Data from multiple cattle feeding operations were used to generate true ranges of respiratory disease prevalence and associated mortality. Input variables were combined into a single model that calculated estimated net returns for animals by diagnostic category (true positive, false positive, false negative, and true negative) based on the prevalence, sensitivity, and specificity for each iteration. Net returns for each diagnostic category were multiplied by the proportion of animals in each diagnostic category to determine group profitability. Apparent prevalence was categorized into low (increasing specificity created more rapid, positive change in net returns than increasing sensitivity. Improvement of diagnostic specificity, perhaps through a confirmatory test interpreted in series or pen-level diagnostics, can increase diagnostic value more than improving sensitivity. Mortality risk was the primary driver for net returns. The results from this study are important for determining future research priorities to analyze diagnostic techniques for bovine respiratory disease and provide a novel way for modeling diagnostic tests.

  4. Common pitfalls in statistical analysis: Understanding the properties of diagnostic tests - Part 1.

    Science.gov (United States)

    Ranganathan, Priya; Aggarwal, Rakesh

    2018-01-01

    In this article in our series on common pitfalls in statistical analysis, we look at some of the attributes of diagnostic tests (i.e., tests which are used to determine whether an individual does or does not have disease). The next article in this series will focus on further issues related to diagnostic tests.

  5. Physical examination tests of the shoulder: a systematic review and meta-analysis of diagnostic test performance.

    Science.gov (United States)

    Gismervik, Sigmund Ø; Drogset, Jon O; Granviken, Fredrik; Rø, Magne; Leivseth, Gunnar

    2017-01-25

    Physical examination tests of the shoulder (PETS) are clinical examination maneuvers designed to aid the assessment of shoulder complaints. Despite more than 180 PETS described in the literature, evidence of their validity and usefulness in diagnosing the shoulder is questioned. This meta-analysis aims to use diagnostic odds ratio (DOR) to evaluate how much PETS shift overall probability and to rank the test performance of single PETS in order to aid the clinician's choice of which tests to use. This study adheres to the principles outlined in the Cochrane guidelines and the PRISMA statement. A fixed effect model was used to assess the overall diagnostic validity of PETS by pooling DOR for different PETS with similar biomechanical rationale when possible. Single PETS were assessed and ranked by DOR. Clinical performance was assessed by sensitivity, specificity, accuracy and likelihood ratio. Six thousand nine-hundred abstracts and 202 full-text articles were assessed for eligibility; 20 articles were eligible and data from 11 articles could be included in the meta-analysis. All PETS for SLAP (superior labral anterior posterior) lesions pooled gave a DOR of 1.38 [1.13, 1.69]. The Supraspinatus test for any full thickness rotator cuff tear obtained the highest DOR of 9.24 (sensitivity was 0.74, specificity 0.77). Compression-Rotation test obtained the highest DOR (6.36) among single PETS for SLAP lesions (sensitivity 0.43, specificity 0.89) and Hawkins test obtained the highest DOR (2.86) for impingement syndrome (sensitivity 0.58, specificity 0.67). No single PETS showed superior clinical test performance. The clinical performance of single PETS is limited. However, when the different PETS for SLAP lesions were pooled, we found a statistical significant change in post-test probability indicating an overall statistical validity. We suggest that clinicians choose their PETS among those with the highest pooled DOR and to assess validity to their own specific clinical

  6. Evaluation of the diagnostic performance and operational characteristics of four rapid immunochromatographic syphilis tests in Burkina Faso.

    Science.gov (United States)

    Bocoum, Fadima Yaya; Ouédraogo, Henri; Tarnagda, Grissoum; Kiba, Alice; Tiendrebeogo, Simon; Bationo, Fabrice; Liestman, Benjamin; Diagbouga, Serge; Zarowsky, Christina; Traoré, Ramata Ouédraogo; Kouanda, Séni

    2015-06-01

    Little information is available on the rapid diagnostic testing for syphilis in Burkina Faso. The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Four rapid syphilis tests commercially available in Burkina Faso were evaluated using archived serum samples and Treponema pallidum hemagglutination assay (TPHA) as the gold standard. Blood samples were collected between November 2011 and June 2012 from blood donors at the Regional Blood Transfusion Center of Ouagadougou. The sensitivity and specificity of the tests were calculated. Evaluation of operational characteristics such as clarity of pamphlet, complexity of technique, duration, was conducted in a first-level healthcare center with health workers in maternity unit. Alere DetermineTM Syphilis was the most sensitive of the four rapid syphilis tests evaluated. It was followed by SD Bioline Syphilis 3.0, Cypress Diagnostics Syphilis Quick test and Accu-Tell ® Rapid Anti-TP, which was the least sensitive. The four tests demonstrated a good diagnostic specificity for syphilis (95-98%), and healthcare workers found them easy to use. The study allowed confirming the good performance of three of four rapid syphilis tests in Burkina Faso. More research will be conducted to assess the feasibility of introducing selected rapid tests for syphilis in antenatal care services.

  7. Field-testing of the ICHD-3 beta diagnostic criteria for classical trigeminal neuralgia

    DEFF Research Database (Denmark)

    Maarbjerg, Stine; Sørensen, Morten Togo; Gozalov, Aydin

    2015-01-01

    INTRODUCTION: We aimed to field-test the beta version of the third edition of the International Classification of Headache Disorders (ICHD-3 beta) diagnostic criteria for classical trigeminal neuralgia (TN). The proposed beta draft of the 11th version of the International Classification of Diseases...... (ICD-11 beta) is almost exclusively based on the ICHD-3 beta classification structure although slightly abbreviated. We compared sensitivity and specificity to ICHD-2 criteria, and evaluated the needs for revision. METHODS: Clinical characteristics were systematically and prospectively collected from...

  8. Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: A practical review for clinical researchers-Part II. general guidance and tips

    International Nuclear Information System (INIS)

    Kim, Kyung Won; Choi, Sang Hyun; Huh, Jimi; Park, Seong Ho; Lee, June Young

    2015-01-01

    Meta-analysis of diagnostic test accuracy studies differs from the usual meta-analysis of therapeutic/interventional studies in that, it is required to simultaneously analyze a pair of two outcome measures such as sensitivity and specificity, instead of a single outcome. Since sensitivity and specificity are generally inversely correlated and could be affected by a threshold effect, more sophisticated statistical methods are required for the meta-analysis of diagnostic test accuracy. Hierarchical models including the bivariate model and the hierarchical summary receiver operating characteristic model are increasingly being accepted as standard methods for meta-analysis of diagnostic test accuracy studies. We provide a conceptual review of statistical methods currently used and recommended for meta-analysis of diagnostic test accuracy studies. This article could serve as a methodological reference for those who perform systematic review and meta-analysis of diagnostic test accuracy studies

  9. 30 CFR 250.523 - How long do I keep records of casing pressure and diagnostic tests?

    Science.gov (United States)

    2010-07-01

    ... and diagnostic tests? 250.523 Section 250.523 Mineral Resources MINERALS MANAGEMENT SERVICE... casing pressure and diagnostic tests? Records of casing pressure and diagnostic tests must be kept at the field office nearest the well for a minimum of 2 years. The last casing diagnostic test for each casing...

  10. Recall Tests Are Effective to Detect Mild Cognitive Impairment: A Systematic Review and Meta-analysis of 108 Diagnostic Studies.

    Science.gov (United States)

    Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S

    2017-09-01

    Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most

  11. Diagnostic accuracy and optimal use of three tests for tuberculosis in live badgers.

    Directory of Open Access Journals (Sweden)

    Julian A Drewe

    Full Text Available BACKGROUND: Accurate diagnosis of tuberculosis (TB due to infection with Mycobacterium bovis is notoriously difficult in live animals, yet important if we are to understand the epidemiology of TB and devise effective strategies to limit its spread. Currently available tests for diagnosing TB in live Eurasian badgers (Meles meles remain unvalidated against a reliable gold standard. The aim of the present study was to evaluate the diagnostic accuracy and optimal use of three tests for TB in badgers in the absence of a gold standard. METHODOLOGY/PRINCIPAL FINDINGS: A Bayesian approach was used to evaluate the diagnostic accuracy and optimal use of mycobacterial culture, gamma-interferon assay and a commercially available serological test using multiple samples collected from 305 live wild badgers. Although no single test was judged to be sufficiently sensitive and specific to be used as a sole diagnostic method, selective combined use of the three tests allowed guidelines to be formulated that allow a diagnosis to be made for individual animals with an estimated overall accuracy of 93% (range: 75% to 97%. Employing this approach in the study population of badgers resulted in approximately 13 out of 14 animals having their true infection status correctly classified from samples collected on a single capture. CONCLUSIONS/SIGNIFICANCE: This method of interpretation represents a marked improvement on the current procedure for diagnosing M. bovis infection in live badgers. The results should be of use to inform future test and intervention strategies with the aim of reducing the incidence of TB in free-living wild badger populations.

  12. Improvement of the test quality for specific test problems. Proceedings

    International Nuclear Information System (INIS)

    2011-01-01

    This proceedings CD discusses the many factors that are relevant in nearly all tests, as well as their effects on the validity of the test result. Interfaces with technical rules, staff qualification, POD, and validation of test results by supplementary techniques are presented as well. Three of the 17 papers are available as separate records in the ENERGY database. [de

  13. Diagnostic tests and algorithms used in the investigation of haematuria: systematic reviews and economic evaluation.

    Science.gov (United States)

    Rodgers, M; Nixon, J; Hempel, S; Aho, T; Kelly, J; Neal, D; Duffy, S; Ritchie, G; Kleijnen, J; Westwood, M

    2006-06-01

    To determine the most effective diagnostic strategy for the investigation of microscopic and macroscopic haematuria in adults. Electronic databases from inception to October 2003, updated in August 2004. A systematic review was undertaken according to published guidelines. Decision analytic modelling was undertaken, based on the findings of the review, expert opinion and additional information from the literature, to assess the relative cost-effectiveness of plausible alternative tests that are part of diagnostic algorithms for haematuria. A total of 118 studies met the inclusion criteria. No studies that evaluated the effectiveness of diagnostic algorithms for haematuria or the effectiveness of screening for haematuria or investigating its underlying cause were identified. Eighteen out of 19 identified studies evaluated dipstick tests and data from these suggested that these are moderately useful in establishing the presence of, but cannot be used to rule out, haematuria. Six studies using haematuria as a test for the presence of a disease indicated that the detection of microhaematuria cannot alone be considered a useful test either to rule in or rule out the presence of a significant underlying pathology (urinary calculi or bladder cancer). Forty-eight of 80 studies addressed methods to localise the source of bleeding (renal or lower urinary tract). The methods and thresholds described in these studies varied greatly, precluding any estimate of a 'best performance' threshold that could be applied across patient groups. However, studies of red blood cell morphology that used a cut-off value of 80% dysmorphic cells for glomerular disease reported consistently high specificities (potentially useful in ruling in a renal cause for haematuria). The reported sensitivities were generally low. Twenty-eight studies included data on the accuracy of laboratory tests (tumour markers, cytology) for the diagnosis of bladder cancer. The majority of tumour marker studies

  14. Diaphragmatic height index: new diagnostic test for phrenic nerve dysfunction.

    Science.gov (United States)

    Pornrattanamaneewong, Chaturong; Limthongthang, Roongsak; Vathana, Torpon; Kaewpornsawan, Kamolporn; Songcharoen, Panupan; Wongtrakul, Saichol

    2012-11-01

    The diaphragmatic height index (DHI) was developed to measure the difference in diaphragm levels. The purpose of this study was to set definite DHI values and test the accuracy of these values for use as a new diagnostic test for phrenic nerve dysfunction. All data for this study were obtained from medical charts and retrospectively reviewed. One hundred sixty-five patients with brachial plexus injury who had undergone nerve transfers between 2005 and 2008 were divided into Groups A and B. Group A consisted of 40 patients (mean age 28.0 years) who had sustained concomitant injury of the brachial plexus and phrenic nerves. Patients in Group A1 had right phrenic nerve injury and those in Group A2 had left phrenic nerve injury. Intraoperative direct electrical stimulation of the phrenic nerve was considered the gold standard in assessing nerve function in all patients with brachial plexus injury. Group B consisted of 125 patients (mean age 28.7 years) with brachial plexus injury and normal phrenic nerve function. Group C, the control group, consisted of 80 patients with nonbrachial plexus injury (mean age 34.0 years) who had undergone other kinds of orthopedic operations between April and June 2009. Standard posteroanterior chest radiographs were blindly interpreted using the Siriraj inhouse picture archiving and communication system in all 245 patients in the study. First, a reference line (R line) was drawn along the inferior endplate of T-10. Then, 2 lines (lines A and B) were drawn through the highest point of each diaphragm and parallel to the R line. The difference between these 2 lines divided by the height of T-10 was defined as the DHI. The cutoff points of the DHI for diagnosing right and left phrenic nerve dysfunction were analyzed with a receiver operating characteristic curve. The accuracy of these DHI values was then evaluated. The DHI in Group C was 0.64 ± 0.44, slightly higher than the DHI in Group B, with no significant difference. Diaphragmatic

  15. Correcting biases in psychiatric diagnostic practice in Northwest Russia: Comparing the impact of a general educational program and a specific diagnostic training program

    Directory of Open Access Journals (Sweden)

    Rezvyy Grigory

    2008-04-01

    Full Text Available Abstract Background A general education in psychiatry does not necessary lead to good diagnostic skills. Specific training programs in diagnostic coding are established to facilitate implementation of ICD-10 coding practices. However, studies comparing the impact of these two different educational approaches on diagnostic skills are lacking. The aim of the current study was to find out if a specific training program in diagnostic coding improves the diagnostic skills better than a general education program, and if a national bias in diagnostic patterns can be minimised by a specific training in diagnostic coding. Methods A pre post design study with two groups was carried in the county of Archangels, Russia. The control group (39 psychiatrists took the required course (general educational program, while the intervention group (45 psychiatrists were given a specific training in diagnostic coding. Their diagnostic skills before and after education were assessed using 12 written case-vignettes selected from the entire spectrum of psychiatric disorders. Results There was a significant improvement in diagnostic skills in both the intervention group and the control group. However, the intervention group improved significantly more than did the control group. The national bias was partly corrected in the intervention group but not to the same degree in the control group. When analyzing both groups together, among the background factors only the current working place impacted the outcome of the intervention. Conclusion Establishing an internationally accepted diagnosis seems to be a special skill that requires specific training and needs to be an explicit part of the professional educational activities of psychiatrists. It does not appear that that skill is honed without specific training. The issue of national diagnostic biases should be taken into account in comparative cross-cultural studies of almost any character. The mechanisms of such biases are

  16. Clinical review: Distinguishing constitutional delay of growth and puberty from isolated hypogonadotropic hypogonadism: critical appraisal of available diagnostic tests.

    Science.gov (United States)

    Harrington, Jennifer; Palmert, Mark R

    2012-09-01

    Determining the etiology of delayed puberty during initial evaluation can be challenging. Specifically, clinicians often cannot distinguish constitutional delay of growth and puberty (CDGP) from isolated hypogonadotropic hypogonadism (IHH), with definitive diagnosis of IHH awaiting lack of spontaneous puberty by age 18 yr. However, the ability to make a timely, correct diagnosis has important clinical implications. The aim was to describe and evaluate the literature regarding the ability of diagnostic tests to distinguish CDGP from IHH. A PubMed search was performed using key words "puberty, delayed" and "hypogonadotropic hypogonadism," and citations within retrieved articles were reviewed to identify studies that assessed the utility of basal and stimulation tests in the diagnosis of delayed puberty. Emphasis was given to a test's ability to distinguish prepubertal adolescents with CDGP from those with IHH. Basal gonadotropin and GnRH stimulation tests have limited diagnostic specificity, with overlap in gonadotropin levels between adolescents with CDGP and IHH. Stimulation tests using more potent GnRH agonists and/or human chorionic gonadotropin may have better discriminatory value, but small study size, lack of replication of diagnostic thresholds, and prolonged protocols limit clinical application. A single inhibin B level in two recent studies demonstrated good differentiation between groups. Distinguishing IHH from CDGP is an important clinical issue. Basal inhibin B may offer a simple, discriminatory test if results from recent studies are replicated. However, current literature does not allow for recommendation of any diagnostic test for routine clinical use, making this an important area for future investigation.

  17. Estimating diagnostic test accuracies for Brachyspira hyodysenteriae accounting for the complexities of population structure in food animals.

    Directory of Open Access Journals (Sweden)

    Sonja Hartnack

    Full Text Available For swine dysentery, which is caused by Brachyspira hyodysenteriae infection and is an economically important disease in intensive pig production systems worldwide, a perfect or error-free diagnostic test ("gold standard" is not available. In the absence of a gold standard, Bayesian latent class modelling is a well-established methodology for robust diagnostic test evaluation. In contrast to risk factor studies in food animals, where adjustment for within group correlations is both usual and required for good statistical practice, diagnostic test evaluation studies rarely take such clustering aspects into account, which can result in misleading results. The aim of the present study was to estimate test accuracies of a PCR originally designed for use as a confirmatory test, displaying a high diagnostic specificity, and cultural examination for B. hyodysenteriae. This estimation was conducted based on results of 239 samples from 103 herds originating from routine diagnostic sampling. Using Bayesian latent class modelling comprising of a hierarchical beta-binomial approach (which allowed prevalence across individual herds to vary as herd level random effect, robust estimates for the sensitivities of PCR and culture, as well as for the specificity of PCR, were obtained. The estimated diagnostic sensitivity of PCR (95% CI and culture were 73.2% (62.3; 82.9 and 88.6% (74.9; 99.3, respectively. The estimated specificity of the PCR was 96.2% (90.9; 99.8. For test evaluation studies, a Bayesian latent class approach is well suited for addressing the considerable complexities of population structure in food animals.

  18. Prostate-Specific Antigen (PSA) Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... medlineplus.gov/labtests/prostatespecificantigenpsatest.html Prostate-Specific Antigen (PSA) Test To use the sharing features on this ... enable JavaScript. What is a prostate-specific antigen (PSA) test? A prostate-specific antigen (PSA) test measures ...

  19. Optical diagnostics in the advanced test accelerator (ATA) environment

    International Nuclear Information System (INIS)

    Chong, Y.P.; Cornish, J.P.; Donnelly, D.

    1987-05-01

    The ATA is a 50-MeV, 10-kA, 70-ns pulsed electron beam accelerator that generates an extremely harsh environment for diagnostic measurements. Diagnostic targets placed in the beamline are subject to damage, frequently being destroyed by a single pulse. High radiation (x-ray, gamma, and neutron) and electromagnetic interference levels preclude placing components near the beamline that are susceptible to radiation damage. Examples of such components are integrated circuit elements, hydrocarbons such as Teflon insulation, and optical components that darken, resulting in transmission loss. Optical diagnostics play an important part in measuring experimental parameters such as the beam current density profile. A large number of optical lines of sight (LOS) are routinely deployed along the experimental beamlines that use the ATA beam. Gated TV cameras are located outside the accelerator tunnel, because the tunnel is inaccessible during operations. We will describe and discuss the difficulties, problems, and solutions encountered in making optical measurements in the ATA environment

  20. Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.

    Science.gov (United States)

    Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won

    2016-08-01

    Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.

  1. Elimination of pain improves specificity of clinical diagnostic criteria for adult chronic rhinosinusitis.

    Science.gov (United States)

    Hirsch, Scott D; Reiter, Evan R; DiNardo, Laurence J; Wan, Wen; Schuman, Theodore A

    2017-05-01

    Determine whether the elimination of pain improves accuracy of clinical diagnostic criteria for adult chronic rhinosinusitis. Retrospective cohort study. History, symptoms, nasal endoscopy, and computed tomography (CT) results were analyzed for 1,186 adults referred to an academic otolaryngology clinic with presumptive diagnosis of chronic rhinosinusitis. Clinical diagnosis was rendered using the 1997 Rhinosinusitis Taskforce (RSTF) Guidelines and a modified version eliminating facial pain, ear pain, dental pain, and headache. Four hundred seventy-nine subjects (40%) met inclusion criteria. Among subjects positive by RSTF guidelines, 45% lacked objective evidence of sinonasal inflammation by CT, 48% by endoscopy, and 34% by either modality. Applying modified RSTF diagnostic criteria, 39% lacked sinonasal inflammation by CT, 38% by endoscopy, and 24% by either modality. Using either abnormal CT or endoscopy as the reference standard, modified diagnostic criteria yielded a statistically significant increase in specificity from 37.1% to 65.1%, with a nonsignificant decrease in sensitivity from 79.2% to 70.3%. Analysis of comorbidities revealed temporomandibular joint disorder, chronic cervical pain, depression/anxiety, and psychiatric medication use to be negatively associated with objective inflammation on CT or endoscopy. Clinical diagnostic criteria overestimate the prevalence of chronic rhinosinusitis. Removing facial pain, ear pain, dental pain, and headache increased specificity without a concordant loss in sensitivity. Given the high prevalence of sinusitis, improved clinical diagnostic criteria may assist primary care providers in more accurately predicting the presence of inflammation, thereby reducing inappropriate antibiotic use or delayed referral for evaluation of primary headache syndromes. 4. Laryngoscope, 127:1011-1016, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  2. Testing the validity and acceptability of the diagnostic criteria for Hoarding Disorder: a DSM-5 survey.

    Science.gov (United States)

    Mataix-Cols, D; Fernández de la Cruz, L; Nakao, T; Pertusa, A

    2011-12-01

    The DSM-5 Obsessive-Compulsive Spectrum Sub-Workgroup is recommending the creation of a new diagnostic category named Hoarding Disorder (HD). The validity and acceptability of the proposed diagnostic criteria have yet to be formally tested. Obsessive-compulsive disorder/hoarding experts and random members of the American Psychiatric Association (APA) were shown eight brief clinical vignettes (four cases meeting criteria for HD, three with hoarding behaviour secondary to other mental disorders, and one with subclinical hoarding behaviour) and asked to decide the most appropriate diagnosis in each case. Participants were also asked about the perceived acceptability of the criteria and whether they supported the inclusion of HD in the main manual. Altogether, 211 experts and 48 APA members completed the survey (30% and 10% response rates, respectively). The sensitivity and specificity of the HD diagnosis and the individual criteria were high (80-90%) across various types of professionals, irrespective of their experience with hoarding cases. About 90% of participants in both samples thought the criteria would be very/somewhat acceptable for professionals and sufferers. Most experts (70%) supported the inclusion of HD in the main manual, whereas only 50% of the APA members did. The proposed criteria for HD have high sensitivity and specificity. The criteria are also deemed acceptable for professionals and sufferers alike. Training of professionals and the development and validation of semi-structured diagnostic instruments should improve diagnostic accuracy even further. A field trial is now needed to confirm these encouraging findings with real patients in real clinical settings.

  3. Rapid diagnostic tests for diagnosing uncomplicated non-falciparum or Plasmodium vivax malaria in endemic countries

    Science.gov (United States)

    Abba, Katharine; Kirkham, Amanda J; Olliaro, Piero L; Deeks, Jonathan J; Donegan, Sarah; Garner, Paul; Takwoingi, Yemisi

    2014-01-01

    Background In settings where both Plasmodium vivax and Plasmodium falciparum infection cause malaria, rapid diagnostic tests (RDTs) need to distinguish which species is causing the patients' symptoms, as different treatments are required. Older RDTs incorporated two test lines to distinguish malaria due to P. falciparum, from malaria due to any other Plasmodium species (non-falciparum). These RDTs can be classified according to which antibodies they use: Type 2 RDTs use HRP-2 (for P. falciparum) and aldolase (all species); Type 3 RDTs use HRP-2 (for P. falciparum) and pLDH (all species); Type 4 use pLDH (fromP. falciparum) and pLDH (all species). More recently, RDTs have been developed to distinguish P. vivax parasitaemia by utilizing a pLDH antibody specific to P. vivax. Objectives To assess the diagnostic accuracy of RDTs for detecting non-falciparum or P. vivax parasitaemia in people living in malaria-endemic areas who present to ambulatory healthcare facilities with symptoms suggestive of malaria, and to identify which types and brands of commercial test best detect non-falciparum and P. vivax malaria. Search methods We undertook a comprehensive search of the following databases up to 31 December 2013: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; MEDION; Science Citation Index; Web of Knowledge; African Index Medicus; LILACS; and IndMED. Selection criteria Studies comparing RDTs with a reference standard (microscopy or polymerase chain reaction) in blood samples from a random or consecutive series of patients attending ambulatory health facilities with symptoms suggestive of malaria in non-falciparum endemic areas. Data collection and analysis For each study, two review authors independently extracted a standard set of data using a tailored data extraction form. We grouped comparisons by type of RDT (defined by the combinations of antibodies used), and combined in meta-analysis where appropriate. Average sensitivities and

  4. Performance and Pain Tolerability of Current Diagnostic Allergy Skin Prick Test Devices.

    Science.gov (United States)

    Tversky, Jody R; Chelladurai, Yohalakshmi; McGready, John; Hamilton, Robert G

    2015-01-01

    Allergen skin prick testing remains an essential tool for diagnosing atopic disease and guiding treatment. Sensitivity needs to be defined for newly introduced devices. Our aim was to compare the performance of 10 current allergy skin prick test devices. Single- and multiheaded skin test devices (n = 10) were applied by a single operator in a prospective randomized manner. Histamine (1 and 6 mg/mL) and control diluent were introduced at 6 randomized locations onto the upper and lower arms of healthy subjects. Wheal and flare reactions were measured independently by 2 masked technicians. Twenty-four subjects provided consent, and 768 skin tests were placed. Mean wheal diameter among devices differed from 3.0 mm (ComforTen; Hollister-Stier, Spokane, Wash) to 6.8 mm (UniTest PC; Lincoln Diagnostics, Decatur, Ill) using 1 mg/mL histamine (P Diagnostics, Decatur, Ill; and Sharp-Test; Panatrex, Placentia, Calif) using 6 mg/mL histamine (P pain score of less than 4 on a 10-point visual analog scale. Pain scores were higher among women, but this did not reach statistical significance. The Multi-Test PC and the UniTest PC had the lowest pain scores compared with the other devices. All 10 skin prick test devices displayed good analytical sensitivity and specificity; however, 3 mm cannot arbitrarily be used as a positive threshold. The use of histamine at 1 mg/mL is unacceptable for certain devices but may be preferable for the most sensitive devices. On average, there was no pain score difference between multiheaded and single-head devices. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  5. A Comparison of Salivary Steroid Levels during Diagnostic Tests for Adrenal Insufficiency

    Directory of Open Access Journals (Sweden)

    Michaela Dušková

    2016-01-01

    Full Text Available Numerous diagnostic tests are used to evaluate the hypothalamic-pituitary-adrenal axis (HPA axis. The gold standard is still considered the insulin tolerance test (ITT, but this test has many limitations. Current guidelines therefore recommend the Synacthen test first when an HPA axis insufficiency is suspected. However, the dose of Synacthen that is diagnostically most accurate and sensitive is still a matter of debate. We investigated 15 healthy men with mean/median age 27.4/26 (SD ±4.8 years, and mean/median BMI (body mass index 25.38/24.82 (SD ±3.2 kg/m2. All subjects underwent 4 dynamic tests of the HPA axis, specifically 1 μg, 10 μg, and 250 μg Synacthen (ACTH tests and an ITT. Salivary cortisol, cortisone, pregnenolone, and DHEA (dehydroepiandrosterone were analysed using liquid chromatography-tandem mass spectrometry. During the ITT maximum salivary cortisol levels over 12.5 nmol/l were found at 60 minutes. Maximum cortisol levels in all of the Synacthen tests were higher than this; however, demonstrating that sufficient stimulation of the adrenal glands was achieved. Cortisone reacted similarly as cortisol, i.e. we did not find any change in the ratio of cortisol to cortisone. Pregnenolone and DHEA were higher during the ITT, and their peaks preceded the cortisol peak. There was no increase of pregnenolone or DHEA in any of the Synacthen tests. We demonstrate that the 10 μg Synacthen dose is sufficient stimulus for testing the HPA axis and is also a safe and cost-effective alternative. This dose also largely eliminates both false negative and false positive results.

  6. [Joint diagnostic value of four temperature sensation tests in elderly patients with type 2 diabetic peripheral neuropathy].

    Science.gov (United States)

    Guo, Wei; Li, Yun-Ming; Ai, Zhi-Hua; You, Zhi-Qing; Wan, Yong; Cheng, Ying; Lang, Hong-Mei

    2013-07-01

    To explore the joint diagnostic value of four temperature sensation tests in elderly patients with type 2 diabetic peripheral neuropathy. Thermal sensory analyzer-II were applied to measure cool sensation (CS), warm sensation (WS), cold pain sensation (CP)and heat pain sensation (HP) of 308 elderly patients with type 2 diabetes. Logistic regression model was adopted to create the new variable Temp4 from four temperature sensation tests to diagnose type 2 diabetic peripheral neuropathy. The ROC curve analysis was used to determine the best cut-off points of the four temperature sensation and Temp4, and the diagnostic value of it was evaluated. The means of temperature sensation tests of the diabetic peripheral neuropathy (DPN) group were significantly different from those of the non-DPN group (P sensation tests to diagnose the DPN, the sensitivity of WS test was the highest, and the value was 0.710; but the specificity, positive predictive value, negative predictive value, Youden index, diagnostic accuracy and Kappa value of cold sensation test were the highest, and the values were 0.842, 0.746, 0.799, 0.528, 77.92% and 0.535, respectively; the Kappa values of the other three temperature sensation tests were all greater than 0.4 (P sensation tests (P sensation quantitative tests were in good agreementand could be applied to diagnose DPN; the new variable Temp4 could be used for diagnosis of DPN with a higher diagnostic accuracy.

  7. Evaluation of a rapid diagnostic test for yaws infection in a community surveillance setting.

    Directory of Open Access Journals (Sweden)

    Michael Marks

    2014-09-01

    Full Text Available Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA setting.

  8. Species-specific nested PCR as a diagnostic tool for Brucella ovis infection in rams

    Directory of Open Access Journals (Sweden)

    L.F. Costa

    2013-02-01

    Full Text Available The aim of the present study was to evaluate a species-specific nested PCR based on a previously described species-specific PCR for detection of B. ovis in semen and urine samples of experimentally infected rams. The performance of the species-specific nested PCR was compared with the results of a genus-specific PCR. Fourteen rams were experimentally infected with the Brucella ovis REO 198 strain and samples of semen and urine were collected every week up to 180 days post infection. Out of 83 semen samples collected, 42 (50.6% were positive for the species-specific nested PCR, and 23 (27.7% were positive for the genus-specific PCR. Out of 75 urine samples, 49 (65.3% were positive for the species-specific nested PCR, whereas 11 (14.6% were genus-specific PCR positive. Species-specific nested PCR was significantly more sensitive (P<0.001 than the genus-specific PCR in semen and urine from experimentally infected rams. In conclusion, the species-specific nested PCR developed in this study may be used as a diagnostic tool for the detection of B. ovis in semen and urine samples from suspected rams.

  9. Field evaluation of a dual rapid diagnostic test for HIV infection and syphilis in Lima, Peru.

    Science.gov (United States)

    Bristow, Claire C; Leon, Segundo R; Huang, Emily; Brown, Brandon J; Ramos, Lourdes B; Vargas, Silver K; Flores, Juan A; Caceres, Carlos F; Klausner, Jeffrey D

    2016-05-01

    Screening for HIV and syphilis in key populations is recommended by the WHO to reduce the morbidity, mortality and transmission associated with undiagnosed and untreated infections. Rapid point-of-care tests that can detect multiple infections with a single fingerprick whole blood specimen using a single device are gaining popularity. We evaluated the field performance of a rapid dual HIV and syphilis test in people at high risk of HIV and syphilis infections. Participants included men who have sex with men and transgender women recruited in Lima, Peru. Reference standard testing for detection of HIV and syphilis infections, conducted using blood samples from venipuncture, included Treponema pallidum particle agglutination and fourth-generation HIV enzyme immunoassay for which positive results had a confirmation HIV Western blot test. For the evaluation test, SD BIOLINE HIV/Syphilis Duo test (Standard Diagnostics, Korea), a fingerprick blood specimen was used. Sensitivity and specificity were calculated and the exact binomial method was used to determine 95% CIs. A total of 415 participants were recruited for the study. The dual test sensitivity for detection of T. pallidum infection was 89.2% (95% CI 83.5% to 93.5%) and specificity 98.8% (95% CI 96.5% to 99.8%). For detection of HIV infection, the sensitivity of the dual test was 99.1% (95% CI 94.8% to 100%) and specificity 99.4% (95% CI 97.7% to 99.9%). This high performing dual test should be considered for the use in clinical settings to increase uptake of simultaneous testing of HIV and syphilis and accelerate time to treatment for those who need it. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Specification and acceptance testing of nuclear medicine equipment

    International Nuclear Information System (INIS)

    Wegst, A.V.; Erickson, J.J.

    1984-01-01

    The purchase of nuclear medicine equipment is of prime importance in the operation of a clinical service. Failure to properly evaluate the potential uses of the instrumentation and the various operational characteristics of the equipment can often result in the purchase of inappropriate or inferior instruments. The magnitude of the purchase in terms of time and financial investments make it imperative that the purchase be approached in a systematic manner. Consideration of both the intended clinical functions and personnel requirements is important. It is necessary also to evaluate the ability of the equipment vendor to support the instrumentation after the purchase has been completed and the equipment installed in the clinical site. The desired specifications of the instrument characteristics should be stated in terms that can be verified by acceptance testing. The complexity of modern instrumentation and the sensitivity of it to the environment require the buyer to take into account the potential problems of controlling the temperature, humidity, and electrical power of the installation site. If properly and systematically approached, the purchase of new nuclear medicine instrumentation can result in the acquisition of a powerful diagnostic tool which will have a useful lifetime of many years. If not so approached, it may result in the expenditure of a large amount of money and personnel time without the concomitant return in useful clinical service. (author)

  11. The diagnostic value of specific IgE to Ara h 2 to predict peanut allergy in children is comparable to a validated and updated diagnostic prediction model.

    Science.gov (United States)

    Klemans, Rob J B; Otte, Dianne; Knol, Mirjam; Knol, Edward F; Meijer, Yolanda; Gmelig-Meyling, Frits H J; Bruijnzeel-Koomen, Carla A F M; Knulst, André C; Pasmans, Suzanne G M A

    2013-01-01

    A diagnostic prediction model for peanut allergy in children was recently published, using 6 predictors: sex, age, history, skin prick test, peanut specific immunoglobulin E (sIgE), and total IgE minus peanut sIgE. To validate this model and update it by adding allergic rhinitis, atopic dermatitis, and sIgE to peanut components Ara h 1, 2, 3, and 8 as candidate predictors. To develop a new model based only on sIgE to peanut components. Validation was performed by testing discrimination (diagnostic value) with an area under the receiver operating characteristic curve and calibration (agreement between predicted and observed frequencies of peanut allergy) with the Hosmer-Lemeshow test and a calibration plot. The performance of the (updated) models was similarly analyzed. Validation of the model in 100 patients showed good discrimination (88%) but poor calibration (P original model: sex, skin prick test, peanut sIgE, and total IgE minus sIgE. When building a model with sIgE to peanut components, Ara h 2 was the only predictor, with a discriminative ability of 90%. Cutoff values with 100% positive and negative predictive values could be calculated for both the updated model and sIgE to Ara h 2. In this way, the outcome of the food challenge could be predicted with 100% accuracy in 59% (updated model) and 50% (Ara h 2) of the patients. Discrimination of the validated model was good; however, calibration was poor. The discriminative ability of Ara h 2 was almost comparable to that of the updated model, containing 4 predictors. With both models, the need for peanut challenges could be reduced by at least 50%. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  12. Diagnostic accuracy of triage tests to exclude pulmonary embolism

    NARCIS (Netherlands)

    Mac Gillavry, M. R.; Lijmer, J. G.; Sanson, B. J.; Büller, H. R.; Brandjes, D. P.

    2001-01-01

    We performed a study in 403 prospectively included patients with suspected pulmonary embolism to compare the accuracy of a combination of the SimpliRED D-dimer assay and an intuitive clinical probability estimate with either one alone. Based on a conjoint diagnostic refer, ence standard, including

  13. Comparison of Rapid Diagnostic Tests and Microscopy for Malaria ...

    African Journals Online (AJOL)

    Presumptive treatment of malaria results in significant overuse of antimalarials. This study compared the diagnostic accuracy of Histidine Rich Protein II and plasmodium lactate dehydrogenase (pLDH)-based Rapid Kits( RDTs)and using expert microscopy as the gold standard for the detection of falciparum and ...

  14. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    Science.gov (United States)

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  15. Using molecular diagnostic testing to personalize the treatment of patients with gastrointestinal stromal tumors.

    Science.gov (United States)

    Bannon, Amber E; Klug, Lillian R; Corless, Christopher L; Heinrich, Michael C

    2017-05-01

    The diagnosis and treatment of gastrointestinal stromal tumor (GIST) has emerged as a paradigm for modern cancer treatment ('precision medicine'), as it highlights the importance of matching molecular defects with specific therapies. Over the past two decades, the molecular classification and diagnostic work up of GIST has been radically transformed, accompanied by the development of molecular therapies for specific subgroups of GIST. This review summarizes the developments in the field of molecular diagnosis of GIST, particularly as they relate to optimizing medical therapy. Areas covered: Based on an extensive literature search of the molecular and clinical aspects of GIST, the authors review the most important developments in this field with an emphasis on the differential diagnosis of GIST including mutation testing, therapeutic implications of each molecular subtype, and emerging technologies relevant to the field. Expert commentary: The use of molecular diagnostics to classify GIST has been shown to be successful in optimizing patient treatment, but these methods remain under-utilized. In order to facilitate efficient and comprehensive molecular testing, the authors have developed a decision tree to aid clinicians.

  16. The diagnostic accuracy of the rapid dipstick test to predict asymptomatic urinary tract infection of pregnancy.

    Science.gov (United States)

    Eigbefoh, J O; Isabu, P; Okpere, E; Abebe, J

    2008-07-01

    Untreated urinary tract infection can have devastating maternal and neonatal effects. Thus, routine screening for bacteriuria is advocated. This study was designed to evaluate the diagnostic accuracy of the rapid dipstick test to predict urinary tract infection in pregnancy with the gold standard of urine microscopy, culture and sensitivity acting as the control. The urine dipstick test uses the leucocyte esterase, nitrite and test for protein singly and in combination. The result of the dipstick was compared with the gold standard, urine microscopy, culture and sensitivity using confidence interval for proportions. The reliability and validity of the urine dipstick was also evaluated. Overall, the urine dipstick test has a poor correlation with urine culture (p = 0.125, CI 95%). The same holds true for individual components of the dipstick test. The overall sensitivity of the urine dipstick test was poor at 2.3%. Individual sensitivity of the various components varied between 9.1% for leucocyte esterase and the nitrite test to 56.8% for leucocyte esterase alone. The other components of the dipstick test, the test of nitrite, test for protein and combination of the test (leucocyte esterase, nitrite and proteinuria) appear to decrease the sensitivity of the leucocyte esterase test alone. The ability of the urine dipstick test to correctly rule out urinary tract infection (specificity) was high. The positive predictive value for the dipstick test was high, with the leucocyte esterase test having the highest positive predictive value compared with the other components of the dipstick test. The negative predictive value (NPV) was expectedly highest for the leucocyte esterase test alone with values higher than the other components of the urine dipstick test singly and in various combinations. Compared with the other parameters of the urine dipstick test, singly and in combination, leucocyte esterase appears to be the most accurate (90.25%). The dipstick test has a

  17. Predictive diagnostic value of the tourniquet test for the diagnosis of dengue infection in adults

    Science.gov (United States)

    Mayxay, Mayfong; Phetsouvanh, Rattanaphone; Moore, Catrin E; Chansamouth, Vilada; Vongsouvath, Manivanh; Sisouphone, Syho; Vongphachanh, Pankham; Thaojaikong, Thaksinaporn; Thongpaseuth, Soulignasack; Phongmany, Simmaly; Keolouangkhot, Valy; Strobel, Michel; Newton, Paul N

    2011-01-01

    Objective To examine the accuracy of the admission tourniquet test in the diagnosis of dengue infection among Lao adults. Methods Prospective assessment of the predictive diagnostic value of the tourniquet test for the diagnosis of dengue infection, as defined by IgM, IgG and NS1 ELISAs (Panbio Ltd, Australia), among Lao adult inpatients with clinically suspected dengue infection. Results Of 234 patients with clinically suspected dengue infection on admission, 73% were serologically confirmed to have dengue, while 64 patients with negative dengue serology were diagnosed as having scrub typhus (39%), murine typhus (11%), undetermined typhus (12%), Japanese encephalitis virus (5%), undetermined flavivirus (5%) and typhoid fever (3%); 25% had no identifiable aetiology. The tourniquet test was positive in 29.1% (95% CI = 23.2–34.9%) of all patients and in 34.1% (95% CI = 27.0–41.2%) of dengue-seropositive patients, in 32.7% (95% CI = 23.5–41.8) of those with dengue fever and in 36.4% (95% CI = 24.7–48.0) of those with dengue haemorrhagic fever. Interobserver agreement for the tourniquet test was 90.2% (95% CI = 86.4–94.0) (Kappa = 0.76). Using ELISAs as the diagnostic gold standard, the sensitivity of the tourniquet test was 33.5–34%; its specificity was 84–91%. The positive and negative predictive values were 85–90% and 32.5–34%, respectively. Conclusions The admission tourniquet test has low sensitivity and adds relatively little value to the diagnosis of dengue among Lao adult inpatients with suspected dengue. Although a positive tourniquet test suggests dengue and that treatment of alternative diagnoses may not be needed, a negative test result does not exclude dengue. PMID:20958892

  18. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    Science.gov (United States)

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake

  19. Case Report: SPECT/CT as the New Diagnostic Tool for Specific Wrist Pathology.

    Science.gov (United States)

    Linde, Musters; Ten Broek, M; Kraan, G A

    2017-01-01

    Single photon emission computed tomography has been introduced as a promising new diagnostic tool in orthopaedic pathology since the early 90'. Computed tomography, the combined with SPECT, gives insight in the specific sight of wrist pathology. Literature already supports introduction of SPECT/CT in wrist pathology, but clinical application is lagging. A 40yr old patient reported first in 2004 with persisting pain after a right distal radius fracture. Several diagnostics and operative interventions were performed, all unsuccessful. Because of the persisting pain a SPECT-CT was performed which showed a cyst in the hamate bone, which was successfully enucleated. The patient was finally pain free at recent follow-up. With a QDash-score of 43 and a PRW (H) E-DLV-score of 58/150. In this case report, SPECT/CT proved a very sensitive diagnostic tool for specific pathology of the wrist. It offered precise localisation and thereby the clinically suspected diagnosis was confirmed and the patient successfully treated.

  20. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    Science.gov (United States)

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  1. Development, Evaluation, and Integration of a Quantitative Reverse-Transcription Polymerase Chain Reaction Diagnostic Test for Ebola Virus on a Molecular Diagnostics Platform.

    Science.gov (United States)

    Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B; Nauwelaers, David; Ariën, Kevin K

    2016-10-15

     The 2013-2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV).  The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus.  The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%.  The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  2. A Plasma Diagnostic Set for the Study of a Variable Specific Impulse Magnetoplasma Rocket

    Science.gov (United States)

    Squire, J. P.; Chang-Diaz, F. R.; Bengtson Bussell, R., Jr.; Jacobson, V. T.; Wootton, A. J.; Bering, E. A.; Jack, T.; Rabeau, A.

    1997-11-01

    The Advanced Space Propulsion Laboratory (ASPL) is developing a Variable Specific Impulse Magnetoplasma Rocket (VASIMR) using an RF heated magnetic mirror operated asymmetrically. We will describe the initial set of plasma diagnostics and data acquisition system being developed and installed on the VASIMR experiment. A U.T. Austin team is installing two fast reciprocating probes: a quadruple Langmuir and a Mach probe. These measure electron density and temperature profiles, electrostatic plasma fluctuations, and plasma flow profiles. The University of Houston is developing an array of 20 highly directional Retarding Potential Analyzers (RPA) for measuring ion energy distribution function profiles in the rocket plume, giving a measurement of total thrust. We have also developed a CAMAC based data acquisition system using LabView running on a Power Macintosh communicating through a 2 MB/s serial highway. We will present data from initial plasma operations and discuss future diagnostic development.

  3. Synthesis of evidence of diagnostic tests and preventive programs identifying pre-diabetes type

    Directory of Open Access Journals (Sweden)

    Dagmar Tučková

    2015-09-01

    Full Text Available Introduction: Type 2 diabetes mellitus (T2D has become the main type of diabetes in children and it is expected that in countries with high income diabetes it is projected to be one of the leading causes of death by 2030. Another fact is that programs and tests diagnosing pre-diabetes type 2 (T2P-DMC are missing. Methods: The aim of the paper is to present the steps for the synthesis of the evidence within the brand new type of the systematic review (SR: SR of diagnostic test accuracy (DTA. Using the acronym PIRD it was developed a review question, search strategy and inclusion and exclusion criteria. Results: The initial search was done in two databases (MedLine and Cinahl with 2 025 results. The second search after the improvement of the sensitivity and the specificity was done in 15 databases with 3 681 results. Conclusion: This methodological paper introduces how to conduct the systematic review protocols of diagnostic test accuracy on the example of T2P-DMC.

  4. Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings

    Science.gov (United States)

    Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V

    2014-01-01

    Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389

  5. Clinical approach to obscure GI bleeding - Diagnostic testing and management

    Directory of Open Access Journals (Sweden)

    Prashanth Prabakaran

    2013-01-01

    Full Text Available Obscure gastrointestinal bleeding (OGIB can present as a diagnostic dilemma and management can be challenging. The search for causes of OGIB is usually centered on visualizing the small bowel, and in the past decade, the technology to visualize the entire small bowel has significantly advanced. Moreover, small bowel endoscopic imaging has replaced, in many instances, prior radiographic evaluation for obscure GI bleeding. These new modalities, such as small bowel capsule endoscopy (CE, balloon-assisted deep enteroscopy [double balloon enteroscopy (DBE and single balloon enteroscopy (SBE], and overtube-assisted deep enteroscopy (spiral enteroscopy, are paving the way toward more accurately identifying and treating patients with OGIB. We will review the diagnostic modalities available in evaluating a patient with OGIB and also propose the management based on clinical and endoscopic findings.

  6. Helicobacter pylori diagnostic tests in children: review of the literature from 1999 to 2009.

    Science.gov (United States)

    Guarner, Jeannette; Kalach, Nicolas; Elitsur, Yoram; Koletzko, Sibylle

    2010-01-01

    The array of tests that can be used for diagnosis of Helicobacter pylori infection is large, and it can be confusing to define which test to use particularly in children where results may not be comparable to those obtained in adult patients. Using PubMed, we reviewed the English literature from January 1999 to May 2009 to identify articles that determined sensitivity and specificity of H. pylori invasive and non-invasive diagnostic tests in children. We excluded articles that presented a review of the literature, abstracts, case reports, or series where children's results could not be separated from adult populations. Of the tissue based methods, rapid urease tests have better sensitivity than histology to detect presence of H. pylori; however, histology can detect the pathology associated with disease including gastritis, intestinal metaplasia, and other conditions that could be the cause of the child's symptoms. Culture of gastric tissues or stool has 100% specificity but sensitivity is low. Of the serologic tests, immunoblot has the best sensitivity. The urea breath tests have >75% sensitivity for detection of H. pylori before and after treatment. Immunoassays in stool using monoclonal antibodies have >95% sensitivity for detection of H. pylori before and after treatment. PCR testing can be performed in tissue and stool samples and can detect genes associated to antibiotic resistance. In summary, the current commercial non-invasive tests have adequate sensitivity and specificity for detecting the presence of H. pylori; however, endoscopy with histopathology is the only method that can detect H. pylori and lesions associated with the infection.

  7. Diagnostic validity of physical examination tests for common knee disorders: An overview of systematic reviews and meta-analysis.

    Science.gov (United States)

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Roy, Jean-Sébastien; Desmeules, François

    2017-01-01

    More evidence on diagnostic validity of physical examination tests for knee disorders is needed to lower frequently used and costly imaging tests. To conduct a systematic review of systematic reviews (SR) and meta-analyses (MA) evaluating the diagnostic validity of physical examination tests for knee disorders. A structured literature search was conducted in five databases until January 2016. Methodological quality was assessed using the AMSTAR. Seventeen reviews were included with mean AMSTAR score of 5.5 ± 2.3. Based on six SR, only the Lachman test for ACL injuries is diagnostically valid when individually performed (Likelihood ratio (LR+):10.2, LR-:0.2). Based on two SR, the Ottawa Knee Rule is a valid screening tool for knee fractures (LR-:0.05). Based on one SR, the EULAR criteria had a post-test probability of 99% for the diagnosis of knee osteoarthritis. Based on two SR, a complete physical examination performed by a trained health provider was found to be diagnostically valid for ACL, PCL and meniscal injuries as well as for cartilage lesions. When individually performed, common physical tests are rarely able to rule in or rule out a specific knee disorder, except the Lachman for ACL injuries. There is low-quality evidence concerning the validity of combining history elements and physical tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Accuracy of an Immunochromatographic Diagnostic Test (ICT Malaria Combo Cassette Test) Compared to Microscopy among under Five-Year-Old Children when Diagnosing Malaria in Equatorial Guinea

    Science.gov (United States)

    Portero, José-Luis; Rubio-Yuste, Maria; Descalzo, Miguel Angel; Raso, Jose; Lwanga, Magdalena; Obono, Jaquelina; Nseng, Gloria; Benito, Agustin; Cano, Jorge

    2010-01-01

    Conventional malaria diagnosis based on microscopy raises serious difficulties in weak health systems. Cost-effective and sensitive rapid diagnostic tests have been recently proposed as alternatives to microscopy. In Equatorial Guinea, a study was conducted to assess the reliability of a rapid diagnostic test compared to microscopy. The study was designed in accordance with the directives of the Standards for Reporting Diagnostic Accuracy Initiative (STARD). Peripheral thick and thin films for the microscopy diagnosis and a rapid immunochromatographic test (ICT Malaria Combo Cassette Test) were performed on under five-year-old children with malaria suspicion. The ICT test detected Plasmodium spp. infection with a sensitivity of 81.5% and a specificity of 81.9% while P. falciparum diagnosis occurred with a sensitivity of 69.7% and a specificity of 73.7%. The sensitivity of the ICT test increased with higher parasitemias. The general results showed little concordance between the ICT test and microscopy (kappa = 0.28, se: 0.04). In Equatorial Guinea, the ICT Malaria Combo Cassette Test has proven to be an acceptable test to detect high P. falciparum parasitemias. However, the decrease of sensitivity at medium and low parasitemias hampers that ICT can replace properly performed microscopy at present in the diagnosis of malaria in children. PMID:22332024

  9. DETECTION OF RABIES VIRAL ANTIGEN IN CATTLE BY RAPID IMMUNOCHROMTOGRAPHIC DIAGNOSTIC TEST

    Directory of Open Access Journals (Sweden)

    Santanu Panda

    2016-06-01

    Full Text Available In recent years, improved quality, accuracy and speed for diagnosis of rabies has been adopted for rabies control strategies in developing countries. In field condition, rapid immunochromtographic diagnostic test (RIDT is a true requirement for rapid epidemiological surveillance of rabies. In the present study, a total of ten numbers of rabies suspected cattle brain sample form different parts of West Bengal, India were examined through RIDT. The results revealed that one sample was found to be positive. The test was established as powerful screening tool for rabies with high sensitivity and specificity. Thus, RIDT can be employed as a reliable and quick approach for diagnosis and control of rabies under field condition.

  10. Calculating patient specific doses in X-ray diagnostics and from radiopharmaceuticals

    International Nuclear Information System (INIS)

    Lampinen, J.

    2000-01-01

    The risk associated with exposure to ionising radiation is dependent on the characteristics of the exposed individual. The size and structure of the individual influences the absorbed dose distribution in the organs. Traditional methods used to calculate the patient organ doses are based on standardised calculation phantoms, which neglect the variance of the patient size or even sex. When estimating the radiation dose of an individual patient, patient specific calculation methods must be used. Methods for patient specific dosimetry in the fields of X-ray diagnostics and diagnostic and therapeutic use of radiopharmaceuticals were proposed in this thesis. A computer program, ODS-60, for calculating organ doses from diagnostic X-ray exposures was presented. The calculation is done in a patient specific phantom with depth dose and profile algorithms fitted to Monte Carlo simulation data from a previous study. Improvements to the version reported earlier were introduced, e.g. bone attenuation was implemented. The applicability of the program to determine patient doses from complex X-ray examinations (barium enema examination) was studied. The conversion equations derived for female and male patients as a function of patient weight gave the smallest deviation from the actual patient doses when compared to previous studies. Another computer program, Intdose, was presented for calculation of the dose distribution from radiopharmaceuticals. The calculation is based on convolution of an isotope specific point dose kernel with activity distribution, obtained from single photon emission computed tomography (SPECT) images. Anatomical information is taken from magnetic resonance (MR) or computed tomography (CT) images. According to a phantom study, Intdose agreed within 3 % with measurements. For volunteers administered diagnostic radiopharmaceuticals, the results given by Intdose were found to agree with traditional methods in cases of medium sized patients. For patients

  11. Bench-top validation testing of selected immunological and molecular Renibacterium salmoninarum diagnostic assays by comparison with quantitative bacteriological culture

    Science.gov (United States)

    Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.

    2013-01-01

    No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.

  12. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    Directory of Open Access Journals (Sweden)

    Amanda VanSteelandt

    Full Text Available Rapid Diagnostic Tests (RDTs for Ebola Virus Disease (EVD at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program.Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1 a technical questionnaire filled by the lab technicians who performed the RDTs, (2 a checklist filled by the evaluator during the site visits, and (3 direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8% expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8 but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program.The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  13. A comprehensive test specification for pulse fission counters

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, D L [Control and Instrumentation Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1962-02-15

    The following test specification is based on the memorandum AERE - M 728 which it now replaces It contains a standard acceptance test procedure for the many U.K.A.E.A, designed pulse fission counters now commercially available. This test specification may be used for any pulse fission counter provided a specification sheet as shown in Appendix 3 is supplied to the contractor quoting this report and including specified values for the measured quantities. (author)

  14. Compounding diagnostic delays: a qualitative study of point-of-care testing in South Africa.

    Science.gov (United States)

    Engel, Nora; Davids, Malika; Blankvoort, Nadine; Pai, Nitika Pant; Dheda, Keertan; Pai, Madhukar

    2015-04-01

    Successful point-of-care (POC) testing (completion of test-and-treat cycle in one patient encounter) has immense potential to reduce diagnostic and treatment delays, and improve patient and public health outcomes. We explored what tests are done and how in public/private, rural/urban hospitals and clinics in South Africa and whether they can ensure successful POC testing. This qualitative research study examined POC testing across major diseases in Cape Town, Durban and Eastern Cape. We conducted 101 semi-structured interviews and seven focus group discussions with doctors, nurses, community health workers, patients, laboratory technicians, policymakers, hospital managers and diagnostic manufacturers. In South Africa, diagnostics are characterised by a centralised system. Most tests conducted on the spot can be made to work successfully as POC tests. The majority of public/private clinics and smaller hospitals send samples via couriers to centralised laboratories and retrieve results the same way, via internet, fax or phone. The main challenge to POC testing lies in transporting samples and results, while delays risk patient loss from diagnostic/treatment pathways. Strategies to deal with associated delays create new problems, such as artificially prolonged turnaround times, strains on human resources and quality of testing, compounding additional diagnostic and treatment delays. For POC testing to succeed, particular characteristics of diagnostic ecosystems and adaptations of professional practices to overcome associated challenges must be taken into account. © 2014 John Wiley & Sons Ltd.

  15. Diagnostic accuracy of point-of-care tests for hepatitis C virus infection: a systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Mehnaaz Sultan Khuroo

    Full Text Available Point-of-care tests provide a plausible diagnostic strategy for hepatitis C infection in economically impoverished areas. However, their utility depends upon the overall performance of individual tests.A literature search was conducted using the metasearch engine Mettā, a query interface for retrieving articles from five leading medical databases. Studies were included if they employed point-of-care tests to detect antibodies of hepatitis C virus and compared the results with reference tests. Two reviewers performed a quality assessment of the studies and extracted data for estimating test accuracy.Thirty studies that had evaluated 30 tests fulfilled the inclusion criteria. The overall pooled sensitivity, specificity, positive likelihood-ratio, negative likelihood-ratio and diagnostic odds ratio for all tests were 97.4% (95% CI: 95.9-98.4, 99.5% (99.2-99.7, 80.17 (55.35-116.14, 0.03 (0.02-0.04, and 3032.85 (1595.86-5763.78, respectively. This suggested a high pooled accuracy for all studies. We found substantial heterogeneity between studies, but none of the subgroups investigated could account for the heterogeneity. Genotype diversity of HCV had no or minimal influence on test performance. Of the seven tests evaluated in the meta-regression model, OraQuick had the highest test sensitivity and specificity and showed better performance than a third generation enzyme immunoassay in seroconversion panels. The next highest test sensitivities and specificities were from TriDot and SDBioline, followed by Genedia and Chembio. The Spot and Multiplo tests produced poor test sensitivities but high test specificities. Nine of the remaining 23 tests produced poor test sensitivities and specificities and/or showed poor performances in seroconversion panels, while 14 tests had high test performances with diagnostic odds ratios ranging from 590.70 to 28822.20.Performances varied widely among individual point-of-care tests for diagnosis of hepatitis C virus

  16. Inventions leading to the development of the diagnostic test kit industry--from the modern pregnancy test to the sandwich assays.

    Science.gov (United States)

    Wide, Leif

    2005-01-01

    The universities are encouraged by the government nowadays to stimulate innovations and also to provide the proper machinery for assisting the protection and commercialisation of innovations. A better understanding of the innovation process may help to create an atmosphere suitable for inventions at the university. Examples can be taken from successful innovations previously made at the university. During the 1960's I made a series of inventions, which ultimately led to the development of the diagnostic test kit industry. The first, which I made as an undergraduate, was a simple and reliable test kit for diagnosis of pregnancy. This was followed by the solid phase radioimmunoassay and a solid phase assay for vitamin B12; next, the dual specific non-competitive sandwich assay and the in-vitro test for diagnosis of allergy, called RAST (Radioallergosorbent test). Organon in Holland with the pregnancy test kit, and Pharmacia in Sweden with test kits for radioimmunoassay, became pioneers among the diagnostic test kit industries. Pharmacia Diagnostics later became one of the leading diagnostic test kit companies in the world and has continued to be so in the field of allergy diagnosis. Each one of these inventions started with a few unique observations leading to a technical development. The pregnancy test as well as the allergy test emerged from the development of assay methods with unique qualities with the subsequent search for appropriate applications. The foreseeing of a commercial value on a future market was a very important step. This was followed by the search for a suitable industry interested to exploit the invention with its new business opportunity i.e. apply for a patent, produce and market the products, which in my case consisted of the necessary reagents and equipments for particular diagnostic tests. Finally, an agreement had to be settled between the entrepreneur and the inventors. This report describes these inventions and particularly discusses some

  17. Acute appendicitis: sensitivity, specificity and diagnostic accuracy of thin-section contrast-enhanced CT findings

    International Nuclear Information System (INIS)

    Lee, Ji Yon; Choi, Dong Il; Park, Hae Won; Lee, Young Rae; Kook, Shin Ho; Kwang, Hyon Joo; Kim, Seung Kwon; Chung, Eun Chul

    2002-01-01

    To assess the sensitivity, specificity, and diagnostic accuracy of individual contrast-enhanced helical CT findings of acute appendicitis. We retrospectively reviewed the appendiceal helical CT scans, obtained after intravenous contrast administration (abdomen; 7-mm collimation, abdominopelvic junction; 5-mm collimation), of 50 patients with surgically proven acute appendicitis and 112 with alternative diagnoses. The following parameters were analysed by three radiologists: enlarged appendix (>6 mm in diameter), appendiceal wall thickening, appendiceal wall enhancement, no identification of the appendix, appendicolith(s), (appendiceal) intraluminal air, abscess, lymphadenopathy, terminal ileal wall thickening, focal cecal apical thickening, focal colonic wall thickening, and segmental colonic wall thickening. The CT findings of acute appendicitis that statistically distinguished it from alternative diagnoses were an enlarged appendix (sensitivity; 92%, specificity; 93%, diagnostic accuracy; 93%), appendiceal wall thickening (for these three parameters: 68%, 96% and 88%, respectively), periappendiceal fat stranding (90%, 79%, 82%), appendiceal wall enhancement (72%, 86%, 82%), appendicolith (16%, 100%, 74%), and focal cecal apical thickening (14%, 100%, 74%) (for each, p<0305). On thin-section contrast-enhanced helical CT, an enlarged appendix and periappendiceal fat stranding were found in 90% or more patients with acute appendicitis. Appendiceal wall thickening and enhancement were alearly demonstrated and significant findings for diagnosis. Less common but specific findings include appendicolith, focal cecal apical thickening and intramural air, can also help us establish a diagnosis of acute appendicitis

  18. Identification of Diagnostic Mitochondrial DNA Single Nucleotide Polymorphisms Specific to Sumatran Orangutan (Pongo abelii Populations

    Directory of Open Access Journals (Sweden)

    Puji Rianti

    2015-10-01

    Full Text Available The hypervariable region I of mitochondrial DNA has frequently been used to distinguish among populations, in particular in species with strong female philopatry. In such cases, populations are expected to diverge rapidly for hypervariable region I markers because of the smaller effective population size and thus increased genetic drift. This rapid divergence leads to the accumulation of mutations exclusively found in one population, which may serve as diagnostic single nucleotide polymorphisms (SNPs. To date, diagnostic SNPs distinctive to Sumatran orangutan populations have not yet been described. However, given the continuously declining numbers of Sumatran orangutans, this information can be vital for effective conservation measures, especially regarding reintroductions of orangutans in rehabilitation centers. Phylogenetic analyses of 54 samples of Sumatran orangutans from nine sampling sites with good provenance, we found five major clades and a total of 20 haplotypes. We propose a total of 52 diagnostic SNPs that are specific to Sumatran orangutan populations. Data can be used to develop restriction fragment length polymorphism assays to carry out genetic assignments using basic laboratory equipment to assign Sumatran orangutan to their population of origin.

  19. Ataques de nervios: proposed diagnostic criteria for a culture specific syndrome.

    Science.gov (United States)

    Oquendo, M; Horwath, E; Martinez, A

    1992-09-01

    The authors propose a set of diagnostic criteria and report two cases of ataque de nervios, a syndrome of brief duration seen primarily in Spanish-speaking people of the Caribbean. Following a psychosocial stressor, the afflicted person demonstrates impulsivity, dissociation and communication and perceptual disturbances. The symptoms often begin in the presence of the family, allow a temporary relinquishing of social roles, and result in the mobilization of the social network in support of the person. Further research is needed to improve our understanding of this culture specific syndrome and its relationship to psychiatric disorder.

  20. Using Meta-Analysis to Inform the Design of Subsequent Studies of Diagnostic Test Accuracy

    Science.gov (United States)

    Hinchliffe, Sally R.; Crowther, Michael J.; Phillips, Robert S.; Sutton, Alex J.

    2013-01-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial…

  1. Requirements for appropriate evaluation of diagnostic tests in suspected pulmonary embolism

    NARCIS (Netherlands)

    Sanson, B. J.; Meinders, A. J.; Kraaijenhagen, R. A.; van Beek, E. J.; Büller, H. R.

    1999-01-01

    In contrast to the development of new drugs, strict guidelines for the development of new diagnostic methods do not exist. A diagnostic test can be made available without proper evaluation of its clinical utility, which can lead to its premature introduction and inappropriate use. In this review

  2. Protease activity measurement in milk as a diagnostic test for clinical mastitis in dairy cows

    NARCIS (Netherlands)

    Koop, G.; van Werven, T.; Roffel, S.; Hogeveen, H.; Nazmi, K.; Bikker, F.J.

    2015-01-01

    Due to the increasing use of automated milking systems, automated detection of clinical mastitis is becoming more important. Various in- or on-line diagnostic tests are in use, but generally suffer from false mastitis alerts. In this study, we explored a new diagnostic approach based on measurement

  3. Results of metallographical diagnostic examination of Navy half-watt thermoelectric converters degraded by accelerated tests

    International Nuclear Information System (INIS)

    Rosell, F.E. Jr.; Rouklove, P.G.

    1977-01-01

    To verify the 15-year reliability of the Navy half-watt radioisotope thermoelectric generator (RTG), bismuth--telluride thermoelectric converters were submitted to testing at high temperatures which accelerated the degradation and caused failure of the converters. Metallographic diagnostic examination of failed units verified failure mechanisms. Results of diagnostic examinations are presented

  4. Sensitivity and Specificity of Clinical and Laboratory Otolith Function Tests.

    Science.gov (United States)

    Kumar, Lokesh; Thakar, Alok; Thakur, Bhaskar; Sikka, Kapil

    2017-10-01

    To evaluate clinic based and laboratory tests of otolith function for their sensitivity and specificity in demarcating unilateral compensated complete vestibular deficit from normal. Prospective cross-sectional study. Tertiary care hospital vestibular physiology laboratory. Control group-30 healthy adults, 20-45 years age; Case group-15 subjects post vestibular shwannoma excision or post-labyrinthectomy with compensated unilateral complete audio-vestibular loss. Otolith function evaluation by precise clinical testing (head tilt test-HTT; subjective visual vertical-SVV) and laboratory testing (headroll-eye counterroll-HR-ECR; vesibular evoked myogenic potentials-cVEMP). Sensitivity and specificity of clinical and laboratory tests in differentiating case and control subjects. Measurable test results were universally obtained with clinical otolith tests (SVV; HTT) but not with laboratory tests. The HR-ECR test did not indicate any definitive wave forms in 10% controls and 26% cases. cVEMP responses were absent in 10% controls.HTT test with normative cutoff at 2 degrees deviations from vertical noted as 93.33% sensitive and 100% specific. SVV test with normative cutoff at 1.3 degrees noted as 100% sensitive and 100% specific. Laboratory tests demonstrated poorer specificities owing primarily to significant unresponsiveness in normal controls. Clinical otolith function tests, if conducted with precision, demonstrate greater ability than laboratory testing in discriminating normal controls from cases with unilateral complete compensated vestibular dysfunction.

  5. Quality assurance of radiopharmaceuticals-specifications and test procedures

    International Nuclear Information System (INIS)

    Baldas, J.; Bonnyman, J.; Pojer, P.M.

    1981-08-01

    This report is a compilation of test methods used and specifications adopted for the Radiopharmaceutical Quality Assurance Test Programme conducted by the Australian Radiation Laboratory. In some cases test procedures described have been taken from various Pharmacopoeias or methods published in the literature. In other cases test methods have been developed at the ARL

  6. Is Serial Testing Required to Diagnose Imported Malaria in the Era of Rapid Diagnostic Tests?

    Science.gov (United States)

    Pasricha, Janet M.; Juneja, Surender; Manitta, Joseph; Whitehead, Susan; Maxwell, Ellen; Goh, Wai-Keong; Pasricha, Sant-Rayn; Eisen, Damon P.

    2013-01-01

    Exclusion of malaria traditionally requires three negative serial thick and thin blood films. However, many clinical laboratories now routinely perform rapid diagnostic tests (RDTs) in addition to blood films when malaria is suspected. We sought to determine whether serial testing is necessary in this setting. We examined 388 cases of malaria diagnosed during 1999–2010 at three laboratories in Melbourne, Australia. For each case, we ascertained whether the diagnosis was made on initial or follow-up testing. Nine cases (3.5%) were diagnosed after a negative initial blood film and RDT: 7 Plasmodium vivax, 1 P. ovale, and 1 P. falciparum. Of four case-patients with P. vivax in which clinical data were available, all had recent exposure to antimalarial medication. Our data suggest that among patients who have not received recent anti-malarial therapy, and when RDTs are performed and blood films are prepared, most malaria diagnoses are made by using the first set of tests. PMID:23208885

  7. Diagnostic sensitivity and specificity in a retrospective clinical, radiographic and histopathological study of 166 cystic jaw lesions

    DEFF Research Database (Denmark)

    Therkildsen, N. M.; Andersen, Kristian; Blomlôf, J.

    2014-01-01

    , but a low diagnostic sensitivity in relation to the keratocystic odontogenic tumour (KCOT) was revealed. The radicular cyst, dentigerous cyst and KCOT were the most frequently observed cystic jaw lesions. Conclusion In general, a high diagnostic specificity for all cystic jaw lesions was observed. A low...

  8. The robustness of diagnostic tests for GH deficiency in adults

    DEFF Research Database (Denmark)

    Andersen, Marianne

    2015-01-01

    with recombinant human GH. There is, however, an ongoing debate on how to diagnose GHD, especially in adults. A GH response below the cut-off limit of a GH-stimulation test is required in most cases for establishing GHD in adults. No 'gold standard' GH-stimulation test exists, but some GH stimulation tests may...

  9. Diagnostic value of prostate-specific antigen in women with polycystic ovary syndrome

    Directory of Open Access Journals (Sweden)

    Farahnaz Mardanian

    2011-01-01

    Full Text Available Background: Polycystic ovary syndrome (PCOS is the most common endocrine disorder in women. Its presentation is that of irregular menstruation associated with ovulation defects. Because of adverse outcomes such as metabolic and cardiovascular disorders, its diagnosis and treatment is very important. Therefore, the diagnostic value of prostatespecific antigen (PSA in women with polycystic ovary syndrome was evaluated. Methods: A total of 32 women with PCOS and 32 aged matched healthy females were recruited in this case-control study. The subjects were compared by means of metabolic measures and serum PSA level. The correlations between these markers were evaluated. Sensitivity and specificity values and cut off levels of PSA were established for diagnosis of PCOS. Results: Mean PSA, Ferriman Gallwey score (FGS, luteinizing hormone/follicle stimulating hormone ratio (LH/FSH, testosterone, dehydroepiandrosterone sulfate (DHEAS, 17α hydroxyprogesterone (17α HP levels were significantly higher in PCOS (P<0.001, respectively. PSA levels greater than 0.07 ng/ml yielded a sensitivity of 91% and specificity of 82%, and was helpful as a diagnostic tool for women with PCOS. Circulating androgens and hirsutism were associated with higher levels of PSA in PCOS women. Conclusions: Our results showed direct correlation between PSA, hirsutism and hyperandrogemsm state. Therefore, it seems logical to use PSA level for detection of hyperandrogemsm state in women.

  10. Estimation of diagnostic performance of dementia screening tests: Mini-Mental State Examination, Mini-Cog, Clock Drawing test and Ascertain Dementia 8 questionnaire.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin; Xu, Ying; Liu, Caixia

    2017-05-09

    Dementia is one of the leading causes of dependence in the elderly. This study was conducted to estimate diagnostic performance of dementia screening tests including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) by Bayesian models. A total of 2015 participants aged 65 years or more in eastern China were enrolled. The four screening tests were administered and scored by specifically trained psychiatrists. The prior information of sensitivity and specificity of every screening test was updated via Bayes' theorem to a posterior distribution. Then the results were compared with the estimation based on National Institute of Aging-Alzheimer's Association criteria (NIA-AA). The diagnostic characteristics of Mini-Cog, including sensitivity, specificity, PPV, NPV, especially the Youden index, performed well, even better than the combinations of several screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests.

  11. ITER diagnostics: Maintenance and commissioning in the hot cell test bed

    International Nuclear Information System (INIS)

    Walker, C.I.; Barnsley, R.; Costley, A.E.; Gottfried, R.; Haist, B.; Itami, K.; Kondoh, T.; Loesser, G.D.; Palmer, J.; Sugie, T.; Tesini, A.; Vayakis, G.

    2005-01-01

    In-vessel diagnostic equipment in ITER integrated in six equatorial and 12 upper ports, 16 divertor cassettes and five lower ports is designed to be removed in modules and then repaired, tested and commissioned in the same location at the ITER hot cell. The repair requirements and tests on these components are described along with design features that facilitate repair. The testing establishes the repair strategy, qualifies the refurbishment work and finally checks the mechanical and diagnostic function before the return of the modules. At the hot cell, a dummy port is provided for tests of mechanical and vacuum integrity as well as commissioning of the diagnostic equipment. The scope of the hot cell maintenance and commissioning activities is summarised and an overview of the integration of the diagnostic equipment is given

  12. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  13. Diagnostic Accuracy of Molecular Amplification Tests for Human African Trypanosomiasis-Systematic Review

    NARCIS (Netherlands)

    Mugasa, Claire M.; Adams, Emily R.; Boer, Kimberly R.; Dyserinck, Heleen C.; Büscher, Philippe; Schallig, Henk D. H. F.; Leeflang, Mariska M. G.

    2012-01-01

    Background: A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of

  14. Empirical evidence of design-related bias in studies of diagnostic tests

    NARCIS (Netherlands)

    Lijmer, J. G.; Mol, B. W.; Heisterkamp, S.; Bonsel, G. J.; Prins, M. H.; van der Meulen, J. H.; Bossuyt, P. M.

    1999-01-01

    CONTEXT: The literature contains a large number of potential biases in the evaluation of diagnostic tests. Strict application of appropriate methodological criteria would invalidate the clinical application of most study results. OBJECTIVE: To empirically determine the quantitative effect of study

  15. Urinary tract infections in general practice patients: diagnostic tests versus bacteriological culture.

    NARCIS (Netherlands)

    Nys, S.; Merode, T. van; Bartelds, A.I.M.; Stobberingh, E.E.

    2006-01-01

    Objectives: Urinary tract infections (UTIs) are common bacterial infections encountered in general practice. For the optimal treatment the general practitioner (GP) should rely on the results of diagnostic tests and recent antimicrobial susceptibility of uropathogens. Patients and methods: In total

  16. ANALYSIS AND QUANTITATIVE ASSESSMENT FOR RESULTS OF EDUCATIONAL PROGRAMS APPLICATION BY MEANS OF DIAGNOSTIC TESTS

    Directory of Open Access Journals (Sweden)

    E. L. Kon

    2015-07-01

    Full Text Available Subject of Research.The problem actuality for creation, control and estimation of results for competence-oriented educational programs is formulated and proved. Competences elements and components, assembled in modules, course units and parts of educational program, are defined as objects of control. Specific tasks of proficiency examination for competences and their components are stated; subject matter of the paper is formulated. Methods of Research. Some adapted statements and methods of technical science are offered to be applied for control tasks solution, decoding and estimation of education results. The approach to quantitative estimation of testing results with the use of additive integrated differential criterion of estimation is offered. Main Results. Statements, defining conditions of certain and uncertain (indeterminacy decision-making about proficiency examination for elements of discipline components controlled by test according to test realization results, are formulated and proved. Probabilistic characteristicsof both decision-making variants are estimated. Variants of determinate and fuzzy logic mathematic methods application for decreasing decision-making indeterminancy are offered; further research direction is selected for development of methods and algorithms for results decoding of diagnostic tests set realization. Practical Relevance. It is shown, that proposed approach to quantitative estimation of testing results will give the possibility to automate the procedure of formation and analysis for education results, specified in the competence format.

  17. Test specification for decant pump and winch assembly. Revision 2

    International Nuclear Information System (INIS)

    Staehr, T.W.

    1995-01-01

    This specification provides the requirements for testing of the vertical turbine decant pump including the floating suction with load sensing winch control, instrumentation and the associated PLC/PC control system. All assembly necessary for testing including piping, temporary wiring, etc., shall be performed by the Seller. All referenced figures are at the back of this document. The testing consists of performance testing, winch testing and calibration, instrumentation verification testing and run-in testing of the pump. Testing shall be done in the presence and under the direction of the Buyer in accordance with this procedure

  18. Development of diagnostic test instruments to reveal level student conception in kinematic and dynamics

    Science.gov (United States)

    Handhika, J.; Cari, C.; Suparmi, A.; Sunarno, W.; Purwandari, P.

    2018-03-01

    The purpose of this research was to develop a diagnostic test instrument to reveal students' conceptions in kinematics and dynamics. The diagnostic test was developed based on the content indicator the concept of (1) displacement and distance, (2) instantaneous and average velocity, (3) zero and constant acceleration, (4) gravitational acceleration (5) Newton's first Law, (6) and Newton's third Law. The diagnostic test development model includes: Diagnostic test requirement analysis, formulating test-making objectives, developing tests, checking the validity of the content and the performance of reliability, and application of tests. The Content Validation Index (CVI) results in the category are highly relevant, with a value of 0.85. Three questions get negative Content Validation Ratio CVR) (-0.6), after revised distractors and clarify visual presentation; the CVR become 1 (highly relevant). This test was applied, obtained 16 valid test items, with Cronbach Alpha value of 0.80. It can conclude that diagnostic test can be used to reveal the level of students conception in kinematics and dynamics.

  19. Diagnostic test of predicted height model in Indonesian elderly: a study in an urban area

    Directory of Open Access Journals (Sweden)

    Fatmah Fatmah

    2010-08-01

    Full Text Available Aim In an anthropometric assessment, elderly are frequently unable to measure their height due to mobility and skeletal deformities. An alternative is to use a surrogate value of stature from arm span, knee height, and sitting height. The equations developed for predicting height in Indonesian elderly using these three predictors. The equations put in the nutritional assessment card (NSA of older people. Before the card which is the first new technology in Indonesia will be applied in the community, it should be tested. The study aimed was to conduct diagnostic test of predicted height model in the card compared to actual height.Methods Model validation towards 400 healthy elderly conducted in Jakarta City with cross-sectional design. The study was the second validation test of the model besides Depok City representing semi urban area which was undertaken as the first study.Result Male elderly had higher mean age, height, weight, arm span, knee height, and sitting height as compared to female elderly. The highest correlation between knee height and standing height was similar in women (r = 0.80; P < 0.001 and men (r = 0.78; P < 0.001, and followed by arm span and sitting height. Knee height had the lowest difference with standing height in men (3.13 cm and women (2.79 cm. Knee height had the biggest sensitivity (92.2%, and the highest specificity on sitting height (91.2%.Conclusion Stature prediction equation based on knee-height, arm span, and sitting height are applicable for nutritional status assessment in Indonesian elderly. (Med J Indones 2010;19:199-204Key words: diagnostic test, elderly, predicted height model

  20. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    Science.gov (United States)

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N.

    2014-08-01

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ-ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.

  1. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    International Nuclear Information System (INIS)

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N.

    2014-01-01

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ–ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed

  2. Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER

    Energy Technology Data Exchange (ETDEWEB)

    Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N. [Institution Project center ITER, Moscow (Russian Federation)

    2014-08-21

    In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ–ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.

  3. Drilling and testing specifications for the McGee well

    International Nuclear Information System (INIS)

    Patterson, J.K.

    1982-01-01

    The McGee Well is a part of the Basalt Waste Isolation Project's subsurface site selection and characterization activities. Information from the McGee Well support site hydrologic characterization and repository design. These test specifications include details for the drilling and testing of the McGee. It includes the predicted stratigraphy, the drilling requirements, description of tests to be conducted, intervals selected for hydrologic testing, and a schedule of the drilling and testing activities. 19 refs., 10 figs., 7 tabs

  4. Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement.

    Science.gov (United States)

    McInnes, Matthew D F; Moher, David; Thombs, Brett D; McGrath, Trevor A; Bossuyt, Patrick M; Clifford, Tammy; Cohen, Jérémie F; Deeks, Jonathan J; Gatsonis, Constantine; Hooft, Lotty; Hunt, Harriet A; Hyde, Christopher J; Korevaar, Daniël A; Leeflang, Mariska M G; Macaskill, Petra; Reitsma, Johannes B; Rodin, Rachel; Rutjes, Anne W S; Salameh, Jean-Paul; Stevens, Adrienne; Takwoingi, Yemisi; Tonelli, Marcello; Weeks, Laura; Whiting, Penny; Willis, Brian H

    2018-01-23

    Systematic reviews of diagnostic test accuracy synthesize data from primary diagnostic studies that have evaluated the accuracy of 1 or more index tests against a reference standard, provide estimates of test performance, allow comparisons of the accuracy of different tests, and facilitate the identification of sources of variability in test accuracy. To develop the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline as a stand-alone extension of the PRISMA statement. Modifications to the PRISMA statement reflect the specific requirements for reporting of systematic reviews and meta-analyses of diagnostic test accuracy studies and the abstracts for these reviews. Established standards from the Enhancing the Quality and Transparency of Health Research (EQUATOR) Network were followed for the development of the guideline. The original PRISMA statement was used as a framework on which to modify and add items. A group of 24 multidisciplinary experts used a systematic review of articles on existing reporting guidelines and methods, a 3-round Delphi process, a consensus meeting, pilot testing, and iterative refinement to develop the PRISMA diagnostic test accuracy guideline. The final version of the PRISMA diagnostic test accuracy guideline checklist was approved by the group. The systematic review (produced 64 items) and the Delphi process (provided feedback on 7 proposed items; 1 item was later split into 2 items) identified 71 potentially relevant items for consideration. The Delphi process reduced these to 60 items that were discussed at the consensus meeting. Following the meeting, pilot testing and iterative feedback were used to generate the 27-item PRISMA diagnostic test accuracy checklist. To reflect specific or optimal contemporary systematic review methods for diagnostic test accuracy, 8 of the 27 original PRISMA items were left unchanged, 17 were modified, 2 were added, and 2 were omitted. The 27-item

  5. Lacrimination in Sjogren′s syndrome. Is Schirmer′s test really a useful diagnostic tool?

    Directory of Open Access Journals (Sweden)

    Bhadoria D

    1988-01-01

    Full Text Available In the past, Schinier′s test was used as a diagnostic tool in Sjogren′s Syndrome. In this study, a comparison of 100 normal patients with 2l patients with Sjogren′s Syndrome has been made to study its reliability. It has been concluded that Schimer′s test is of a poor diagnostic value in Sjogren′s Syndrome.

  6. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  7. Predictors of Inappropriate Use of Diagnostic Tests and Management of Bronchiolitis

    Science.gov (United States)

    Sarmiento, Lorena; Rojas-Soto, Gladys E.

    2017-01-01

    Background The aim of the present study was to determine predictors of inappropriate use of diagnostic tests and management of bronchiolitis in a population of hospitalized infants. Methods In an analytical cross-sectional study, we determined independent predictors of the inappropriate use of diagnostic tests and management of bronchiolitis in a population of hospitalized infants. We defined a composite outcome score as the main outcome variable. Results Of the 303 included patients, 216 (71.3%) experienced an inappropriate use of diagnostic tests and treatment of bronchiolitis. After controlling for potential confounders, it was found that atopic dermatitis (OR 5.30; CI 95% 1.14–24.79; p = 0.034), length of hospital stay (OR 1.48; CI 95% 1.08–2.03; p = 0.015), and the number of siblings (OR 1.92; CI 95% 1.13–3.26; p = 0.015) were independent predictors of an inappropriate use of diagnostic tests and treatment of the disease. Conclusions Inappropriate use of diagnostic tests and treatment of bronchiolitis was a highly prevalent outcome in our population of study. Participants with atopic dermatitis, a longer hospital stay, and a greater number of siblings were at increased risk for inappropriate use of diagnostic tests and management of the disease. PMID:28758127

  8. Diagnostic sensitivity and specificity of a participatory disease surveillance method for highly pathogenic avian influenza in household chicken flocks in Indonesia.

    Science.gov (United States)

    Robyn, M; Priyono, W B; Kim, L M; Brum, E

    2012-06-01

    A study was conducted to assess the diagnostic sensitivity and specificity of a disease surveillance method for diagnosis of highly pathogenic avian influenza (HPAI) outbreaks in household chicken flocks used by participatory disease surveillance (PDS) teams in Yogyakarta Province, Indonesia. The Government of Indonesia, in partnership with the Food and Agriculture Organization of the United Nations, has implemented a PDS method for the detection of HPAI outbreaks in poultry since 2006. The PDS method in Indonesia utilizes both a clinical case definition (CD) and the result of a commercial rapid antigen test kit Yogyakarta 55611, to diagnose HPAI outbreaks, primarily in backyard chicken flocks. The following diagnostic sensitivities and specificities were obtained relative to real-time reverse transcription-PCR as the gold standard diagnostic test: 1) 89% sensitivity (CI95: 75%-97%) and 96% specificity (CI95: 89%-99%) for the PDS CD alone; 2) 86% sensitivity (CI95: 71%-95%) and 99% specificity (CI95: 94%-100%) for the rapid antigen test alone; and 3) 84% sensitivity (CI95: 68%-94%) and 100% specificity (CI95: 96%-100%) for the PDS CD result combined with the rapid antigen test result. Based on these results, HPAI outbreaks in extensively raised household chickens can be diagnosed with sufficient sensitivity and specificity using the PDS method as implemented in Indonesia. Subject to further field evaluation, data from this study suggest that the diagnostic sensitivity of the PDS method may be improved by expanding the PDS CD to include more possible clinical presentations of HPAI and by increasing the number of rapid antigen tests to three different birds with HPAI-compatible signs of same flock.

  9. Templates for Cross-Cultural and Culturally Specific Usability Testing

    DEFF Research Database (Denmark)

    Clemmensen, Torkil

    2011-01-01

    The cultural diversity of users of technology challenges our methods for usability testing. This article suggests templates for cross-culturally and culturally specific usability testing, based on studies of usability testing in companies in Mumbai, Beijing, and Copenhagen. Study 1 was a cross...... tests. The result was the construction of templates for usability testing. The culturally specific templates were in Mumbai “user-centered evaluation,” Copenhagen “client-centered evaluation,” and Beijing “evaluator-centered evaluation.” The findings are compared with related research...

  10. Design standards for experimental and field studies to evaluate diagnostic accuracy of tests for infectious diseases in aquatic animals.

    Science.gov (United States)

    Laurin, E; Thakur, K K; Gardner, I A; Hick, P; Moody, N J G; Crane, M S J; Ernst, I

    2018-05-01

    Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial-animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk-of-failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta-analyses of DAS research literature. © 2018 John Wiley & Sons Ltd.

  11. Diagnostic and laboratory test ordering in Northern Portuguese Primary Health Care: a cross-sectional study

    Science.gov (United States)

    Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo

    2017-01-01

    Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family

  12. WISC-III cognitive profiles in children with developmental dyslexia: specific cognitive disability and diagnostic utility.

    Science.gov (United States)

    Moura, Octávio; Simões, Mário R; Pereira, Marcelino

    2014-02-01

    This study analysed the usefulness of the Wechsler Intelligence Scale for Children-Third Edition in identifying specific cognitive impairments that are linked to developmental dyslexia (DD) and the diagnostic utility of the most common profiles in a sample of 100 Portuguese children (50 dyslexic and 50 normal readers) between the ages of 8 and 12 years. Children with DD exhibited significantly lower scores in the Verbal Comprehension Index (except the Vocabulary subtest), Freedom from Distractibility Index (FDI) and Processing Speed Index subtests, with larger effect sizes than normal readers in Information, Arithmetic and Digit Span. The Verbal-Performance IQs discrepancies, Bannatyne pattern and the presence of FDI; Arithmetic, Coding, Information and Digit Span subtests (ACID) and Symbol Search, Coding, Arithmetic and Digit Span subtests (SCAD) profiles (full or partial) in the lowest subtests revealed a low diagnostic utility. However, the receiver operating characteristic curve and the optimal cut-off score analyses of the composite ACID; FDI and SCAD profiles scores showed moderate accuracy in correctly discriminating dyslexic readers from normal ones. These results suggested that in the context of a comprehensive assessment, the Wechsler Intelligence Scale for Children-Third Edition provides some useful information about the presence of specific cognitive disabilities in DD. Practitioner Points. Children with developmental dyslexia revealed significant deficits in the Wechsler Intelligence Scale for Children-Third Edition subtests that rely on verbal abilities, processing speed and working memory. The composite Arithmetic, Coding, Information and Digit Span subtests (ACID); Freedom from Distractibility Index and Symbol Search, Coding, Arithmetic and Digit Span subtests (SCAD) profile scores showed moderate accuracy in correctly discriminating dyslexics from normal readers. Wechsler Intelligence Scale for Children-Third Edition may provide some useful

  13. Characteristics of diagnostic tests used in the 2002 low-pathogenicity avian influenza H7N2 outbreak in Virginia.

    Science.gov (United States)

    Elvinger, François; Akey, Bruce L; Senne, Dennis A; Pierson, F William; Porter-Spalding, Barbara A; Spackman, Erica; Suarez, David L

    2007-07-01

    An outbreak of low-pathogenicity avian influenza (LPAI) H7N2 occurred in 2002 in the Shenandoah Valley, a high-density poultry production region in Virginia. Infected flocks were identified through a combination of observation of clinical signs and laboratory diagnostic tests designed to detect avian influenza (AI) antibodies, virus, or H7-specific RNA. In this report, fitness for purpose of 3 virus/RNA detection assays used during the outbreak was examined: 1) antigen capture enzyme immunoassay (AC-EIA), 2) real-time reverse transcription polymerase chain reaction (RRT-PCR), and 3) virus isolation (VI). Results from testing 762 turkey and 2,216 chicken tracheal swab pooled specimens were analyzed to determine diagnostic sensitivities and specificities of these tests under field conditions using Bayesian techniques for validation of diagnostic tests in the absence of a "gold standard." Diagnostic sensitivities (with 95% probability intervals) in turkeys of AC-EIA and RRT-PCR, in reference to VI, were 65.9 (50.6; 81.3)% and 85.1 (71.9; 95.7)% and of VI 92.9 (78.0; 98.8)% in reference to AC-EIA or 88.7 (76.0; 97.2)% in reference to RRT-PCR; in chickens, diagnostic sensitivities were 75.1 (45.6; 94.2)%, 86.3 (65.9; 97.1)%, and 86.2 (65.8; 97.1)% or 86.3 (66.4; 97.2)%, respectively. Specificities were 99.1 (97.9; 99.8)%, 98.9 (98.0; 99.5)%, and 98.6 (97.4; 99.4)% or 98.8 (97.8; 99.5)% in turkeys and between 99.25% and 99.27% with probability intervals of approximately +/-0.4% for all tests in chickens. Simultaneous use of AC-EIA and RRT-PCR contributed significantly to the rapid control of the outbreak, but the AI RRT-PCR assay with >85% sensitivity and approximately 99% specificity, combined with relatively low cost and fast turnaround, could be used as the sole diagnostic test in outbreaks of LPAI.

  14. Pattern of neural responses to verbal fluency shows diagnostic specificity for schizophrenia and bipolar disorder

    Directory of Open Access Journals (Sweden)

    Walshe Muriel

    2011-01-01

    Full Text Available Abstract Background Impairments in executive function and language processing are characteristic of both schizophrenia and bipolar disorder. Their functional neuroanatomy demonstrate features that are shared as well as specific to each disorder. Determining the distinct pattern of neural responses in schizophrenia and bipolar disorder may provide biomarkers for their diagnoses. Methods 104 participants underwent functional magnetic resonance imaging (fMRI scans while performing a phonological verbal fluency task. Subjects were 32 patients with schizophrenia in remission, 32 patients with bipolar disorder in an euthymic state, and 40 healthy volunteers. Neural responses to verbal fluency were examined in each group, and the diagnostic potential of the pattern of the neural responses was assessed with machine learning analysis. Results During the verbal fluency task, both patient groups showed increased activation in the anterior cingulate, left dorsolateral prefrontal cortex and right putamen as compared to healthy controls, as well as reduced deactivation of precuneus and posterior cingulate. The magnitude of activation was greatest in patients with schizophrenia, followed by patients with bipolar disorder and then healthy individuals. Additional recruitment in the right inferior frontal and right dorsolateral prefrontal cortices was observed in schizophrenia relative to both bipolar disorder and healthy subjects. The pattern of neural responses correctly identified individual patients with schizophrenia with an accuracy of 92%, and those with bipolar disorder with an accuracy of 79% in which mis-classification was typically of bipolar subjects as healthy controls. Conclusions In summary, both schizophrenia and bipolar disorder are associated with altered function in prefrontal, striatal and default mode networks, but the magnitude of this dysfunction is particularly marked in schizophrenia. The pattern of response to verbal fluency is highly

  15. The evolution of whole field optical diagnostics for external transonic testing

    Science.gov (United States)

    Fry, K. A.; Bryanston-Cross, P.

    1992-09-01

    The diagnostic use of quantitative laser flow visualization techniques has increased rapidly over recent years. The limitations imposed by conventional single point techniques such as laser Doppler anemometry are addressed and how they have been overcome by the development of a new family of whole field measurement techniques is demonstrated. In particular near instantaneous whole field velocity data was obtained in a relatively hostile, industrial 2.74 m x 2.44 m transonic wind tunnel (TWT) at the Aircraft Research Association (ARA). The techniques were evaluated for their suitability for making quantitative measurements in the wing/pylon region of a model wing and engine combination. Three optical diagnostic techniques were successfully developed within the context of the ARA facility. The first technique, laser light sheet (LLS), combines the operation of a pulse laser and video capture system to provide a 'real time' visualization of the flow, whereas a second pulse laser technique, Particle Image Velocimetry (PIV) can be used to make specific quantitative whole field instantaneous velocity measurements. The third method, holography, was used to produce a stored three dimensional visualization of the unsteady and shock wave features of the transonic flow in the gully region. A description is made of their installation and operation, and examples are presented of current test results.

  16. FMIT test cell diagnostics: a unique materials challenge

    International Nuclear Information System (INIS)

    Cannon, C.P.; Fuller, J.L.

    1981-08-01

    Basic materials problems are discussed in instrumenting the FMIT test cell, which are applicable to fusion devices in general. Recent data on ceramic-to-metal seals, mineral insulated instrument cables, thermocouples, and optical components are reviewed. The data makes it clear that it would be a mistake to assume that materials and instruments will behave in the FMIT test cell environment as they do in more familiar fission reactors and low power accelerators

  17. Diagnostic laboratory tests for systemic autoimmune rheumatic diseases: unmet needs towards harmonization.

    Science.gov (United States)

    Meroni, Pier Luigi; Borghi, Maria Orietta

    2018-05-01

    Autoantibodies are helpful tools not only for the diagnosis and the classification of systemic autoimmune rheumatic diseases (SARD) but also for sub-grouping patients and/or for monitoring disease activity or specific tissue/organ damage. Consequently, the role of the diagnostic laboratory in the management of SARD is becoming more and more important. The advent of new techniques raised the need of updating and harmonizing our use/interpretation of the assays. We discuss in this opinion paper some of these issues. Indirect immunofluorescence (IIF) was originally suggested as the reference technique for anti-nuclear antibody (ANA) detection as previous solid phase assays (SPA) displayed lower sensitivity. The new available SPA are now offering better results and can represent alternative or even complementary diagnostic tools for ANA detection. The improved sensitivity of SPA technology is also changing our interpretation of the results for other types of autoantibody assays, but we need updating their calibration and new reference materials are going to be obtained in order to harmonize the assays. There is growing evidence that the identification of autoantibody combinations or profiles is helpful in improving diagnosis, patients' subgrouping and predictivity for disease evolution in the field of SARD. We report some explanatory examples to support the idea to make the use of these autoantibody profiles more and more popular. The technological evolution of the autoimmune assays is going to change our routine diagnostic laboratory tests for SARD and validation of new algorithms is needed in order to harmonize our approach to the issue.

  18. Biologics industry challenges for developing diagnostic tests for the National Veterinary Stockpile.

    Science.gov (United States)

    Hardham, J M; Lamichhane, C M

    2013-01-01

    Veterinary diagnostic products generated ~$3 billion US dollars in global sales in 2010. This industry is poised to undergo tremendous changes in the next decade as technological advances move diagnostic products from the traditional laboratory-based and handheld immunologic assays towards highly technical, point of care devices with increased sensitivity, specificity, and complexity. Despite these opportunities for advancing diagnostic products, the industry continues to face numerous challenges in developing diagnostic products for emerging and foreign animal diseases. Because of the need to deliver a return on the investment, research and development dollars continue to be focused on infectious diseases that have a negative impact on current domestic herd health, production systems, or companion animal health. Overcoming the administrative, legal, fiscal, and technological barriers to provide veterinary diagnostic products for the National Veterinary Stockpile will reduce the threat of natural or intentional spread of foreign diseases and increase the security of the food supply in the US.

  19. Diagnostic utility of a direct immunofluorescence test to detect feline coronavirus antigen in macrophages in effusive feline infectious peritonitis.

    Science.gov (United States)

    Litster, A L; Pogranichniy, R; Lin, T-L

    2013-11-01

    The antemortem diagnosis of feline infectious peritonitis (FIP) remains challenging in clinical practice, since current testing methods have suboptimal diagnostic accuracy. Immunohistochemical testing of biopsy specimens and postmortem examination are the standard diagnostic methods, although direct immunofluorescence (DIF) testing to detect feline coronavirus in macrophages in effusion specimens has been reported to have 100% specificity and has been recommended as an antemortem confirmatory test. The aim of this study was to compare the results of DIF testing in antemortem feline effusions with postmortem results using field samples. Effusion specimens were collected antemortem from 17 cats and tested by DIF, followed by postmortem examination. Histopathological examination of specimens collected at postmortem confirmed FIP in 10/17 cases and ruled out FIP out in 7/17 cases. Antemortem DIF testing was positive in all 10 cases confirmed as FIP at postmortem examination. In the seven cats where FIP was ruled out at postmortem examination, DIF was negative in five cases and positive in the remaining two cases. The calculated sensitivity of DIF testing was 100% and the specificity was 71.4%. Duplicate effusion specimens from eight cats that were initially DIF positive were stored refrigerated (4 °C) or at room temperature (22-25 °C) and subjected to serial DIF testing to determine the duration of positive results. DIF-positive specimens stored at both temperatures retained their positive status for at least 2 days. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Fecal microbiome analysis as a diagnostic test for diverticulitis

    NARCIS (Netherlands)

    Daniels, L.; Budding, A. E.; de Korte, N.; Eck, A.; Bogaards, J. A.; Stockmann, H. B.; Consten, E. C.; Savelkoul, P. H.; Boermeester, M. A.

    2014-01-01

    Disease-specific variations in intestinal microbiome composition have been found for a number of intestinal disorders, but little is known about diverticulitis. The purpose of this study was to compare the fecal microbiota of diverticulitis patients with control subjects from a general

  1. 42 CFR 410.33 - Independent diagnostic testing facility.

    Science.gov (United States)

    2010-10-01

    ... supplier of portable x-ray services, a nurse practitioner, or a clinical nurse specialist when he or she... problem and who uses the results in the management of the beneficiary's specific medical problem... physician. That is, the physician in question had a relationship with the beneficiary prior to the...

  2. Diagnostic Accuracy of Obstructive Airway Adult Test for Diagnosis of Obstructive Sleep Apnea.

    Science.gov (United States)

    Gasparini, Giulio; Vicini, Claudio; De Benedetto, Michele; Salamanca, Fabrizio; Sorrenti, Giovanni; Romandini, Mario; Bosi, Marcello; Saponaro, Gianmarco; Foresta, Enrico; Laforì, Andreina; Meccariello, Giuseppe; Bianchi, Alessandro; Toraldo, Domenico Maurizio; Campanini, Aldo; Montevecchi, Filippo; Rizzotto, Grazia; Cervelli, Daniele; Moro, Alessandro; Arigliani, Michele; Gobbi, Riccardo; Pelo, Sandro

    2015-01-01

    The gold standard for the diagnosis of Obstructive Sleep Apnea (OSA) is polysomnography, whose access is however reduced by costs and limited availability, so that additional diagnostic tests are needed. To analyze the diagnostic accuracy of the Obstructive Airway Adult Test (OAAT) compared to polysomnography for the diagnosis of OSA in adult patients. Ninety patients affected by OSA verified with polysomnography (AHI ≥ 5) and ten healthy patients, randomly selected, were included and all were interviewed by one blind examiner with OAAT questions. The Spearman rho, evaluated to measure the correlation between OAAT and polysomnography, was 0.72 (p diagnostic accuracy for the diagnosis of OSA. It has also been shown to be able to discriminate among the different degrees of severity of OSA. Additional large studies aiming to validate this questionnaire as a screening or diagnostic test are needed.

  3. The diagnostic utility of the PSA screening test in a Ghanaian population

    International Nuclear Information System (INIS)

    Gyamfi, O.K.; Aryeetey, D.G.; Achel, D.G.; Gyasi, R. K.

    2004-01-01

    An immunoradiometric (IRMA) protocol was used in the PSA test to measure PSA levels in the sera of 240 men presenting with various complaints bordering on their prostate condition. These men were also made to undergo a fine-needle biopsy. Using the universal cut-off of 4.0ng/ml and the histopathological findings from the biopsies as a 'gold standard' statistical performance criteria (such as Sensitivity, Specificity, False Positive Ratio (FP), False Negative Ratio (FN), Likelihood Ratio (L), Positive Predictive Value (PPV), Negative Predictive Value (NPV), Prior Odds Ratio (Ω and Prevalence) were determined and compared with available literature values. This was to determine the diagnostic efficiency and utility of the PSA test for our Ghanaian population of 240 men. The test returned a Sensitivity and Specificity of 92.9% and 18.6% respectively. The FP and FN ratios were 81.4% and 7.1% respectively. The PPV and NPV were 38.1% and 82.9% respectively while the Prior Odds and Prevalence were 7:13 and 35% respectively. High sensitivities ranging from 79-90% and as low as 34 % have been reported. On the other hand specificities ranging from 59% to 70% have also been reported. The PPV compares favourably with the available literature values to us: within range 28-40%. The PPV and NPV values together with an application of Baye's theorem indicates that in our setting the PSA test is more efficient in ruling out disease than in detecting it. (au)

  4. Auditory Automotive Mechanics Diagnostic Achievement Test. Center Technical Paper No. 2.

    Science.gov (United States)

    Swanson, Richard Arthur

    The Auditory Automotive Mechanics Diagnostic Achievement Test assesses an automobile mechanic's ability to determine mechanical faults from auditory cues alone. The 44-item test and its instructions are recorded on magnetic tape; answer choices are presented on tape, and are also written in the printed test booklets. The norming and validity…

  5. The furosemide diagnostic test in suspected slow-onset heart failure : popular but not useful

    NARCIS (Netherlands)

    Kelder, Johannes C.; Cramer, Maarten J.; Rutten, Frans H.; Plokker, H. W.; Grobbee, Diederick E.; Hoes, Arno W.

    Aims Early, slow-onset heart failure is difficult to diagnose from just signs and symptoms. The physician needs ancillary diagnostic tests. The 'loop-diuretic test' or 'furosemide test', characterized as weight loss and alleviation of symptoms after a short course of a loop-diuretic, could be a

  6. Cost Implications of Value-Based Pricing for Companion Diagnostic Tests in Precision Medicine.

    Science.gov (United States)

    Zaric, Gregory S

    2016-07-01

    Many interpretations of personalized medicine, also referred to as precision medicine, include discussions of companion diagnostic tests that allow drugs to be targeted to those individuals who are most likely to benefit or that allow treatment to be designed in a way such that individuals who are unlikely to benefit do not receive treatment. Many authors have commented on the clinical and competitive implications of companion diagnostics, but there has been relatively little formal analysis of the cost implications of companion diagnostics, although cost reduction is often cited as a significant benefit of precision medicine. We investigate the potential impact on costs of precision medicine implemented through the use of companion diagnostics. We develop a framework in which the costs of companion diagnostic tests are determined by considerations of profit maximization and cost effectiveness. We analyze four scenarios that are defined by the incremental cost-effectiveness ratio of the new drug in the absence of a companion diagnostic test. We find that, in most scenarios, precision medicine strategies based on companion diagnostics should be expected to lead to increases in costs in the short term and that costs would fall only in a limited number of situations.

  7. Formal Specification Based Automatic Test Generation for Embedded Network Systems

    Directory of Open Access Journals (Sweden)

    Eun Hye Choi

    2014-01-01

    Full Text Available Embedded systems have become increasingly connected and communicate with each other, forming large-scaled and complicated network systems. To make their design and testing more reliable and robust, this paper proposes a formal specification language called SENS and a SENS-based automatic test generation tool called TGSENS. Our approach is summarized as follows: (1 A user describes requirements of target embedded network systems by logical property-based constraints using SENS. (2 Given SENS specifications, test cases are automatically generated using a SAT-based solver. Filtering mechanisms to select efficient test cases are also available in our tool. (3 In addition, given a testing goal by the user, test sequences are automatically extracted from exhaustive test cases. We’ve implemented our approach and conducted several experiments on practical case studies. Through the experiments, we confirmed the efficiency of our approach in design and test generation of real embedded air-conditioning network systems.

  8. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    Science.gov (United States)

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  9. A comparison of diagnostic tests for lactose malabsorption - which one is the best?

    Directory of Open Access Journals (Sweden)

    Hovde Øistein

    2009-10-01

    Full Text Available Abstract Background Perceived milk intolerance is a common complaint, and tests for lactose malabsorption (LM are unreliable. This study assesses the agreement between diagnostic tests for LM and describes the diagnostic properties of the tests. Methods Patients above 18 years of age with suspected LM were included. After oral intake of 25 g lactose, a combined test with measurement of serum glucose (s-glucose and hydrogen (H2 and methane (CH4 in expired air was performed and symptoms were recorded. In patients with discrepancies between the results, the combined test was repeated and a gene test for lactose non-persistence was added. The diagnosis of LM was based on an evaluation of all tests. The following tests were compared: Increase in H2, CH4, H2+CH4 and H2+CH4x2 in expired air, increase in s-glucose, and symptoms. The agreement was calculated and the diagnostic properties described. Results Sixty patients were included, seven (12% had LM. The agreement (kappa-values between the methods varied from 0.25 to 0.91. The best test was the lactose breath test with measurement of the increase in H2 + CH4x2 in expired air. With a cut-off level Conclusion The agreement between commonly used methods for the diagnosis of LM was unsatisfactory. A lactose breath test with measurement of H2 + CH4x2 in expired air had the best diagnostic properties.

  10. Diagnostic value of postprandial triglyceride testing in healthy subjects

    DEFF Research Database (Denmark)

    Mihas, Constantinos; Kolovou, Genovefa D; Mikhailidis, Dimitri P

    2011-01-01

    Triglycerides (TGs) are measured in studies evaluating changes in non-fasting lipid profiles after a fat tolerance test (FTT); however, the optimal timing for TG measurements after the oral fat load is unclear. The aim of this study was to evaluate how non-fasting TG levels vary after an oral FTT...

  11. Accuracy of diagnostic antibody tests for coeliac disease in children

    DEFF Research Database (Denmark)

    Giersiepen, Klaus; Lelgemann, Monika; Stuhldreher, Nina

    2012-01-01

    The aim of this study was to summarise the evidence from 2004 to September 2009 on the performance of laboratory-based serological and point of care (POC) tests for diagnosing coeliac disease (CD) in children using histology as reference standard....

  12. Evaluation of Serum Thyroid-Stimulating Hormone Concentration as a Diagnostic Test for Hyperthyroidism in Cats.

    Science.gov (United States)

    Peterson, M E; Guterl, J N; Nichols, R; Rishniw, M

    2015-01-01

    In humans, measurement of serum thyroid-stimulating hormone (TSH) concentration is commonly used as a first-line discriminatory test of thyroid function. Recent reports indicate that canine TSH (cTSH) assays can be used to measure feline TSH and results can help diagnose or exclude hyperthyroidism. To investigate the usefulness of cTSH measurements as a diagnostic test for cats with hyperthyroidism. Nine hundred and seventeen cats with untreated hyperthyroidism, 32 euthyroid cats suspected of having hyperthyroidism, and 131 clinically normal cats. Prospective study. Cats referred to the Animal Endocrine Clinic for suspected hyperthyroidism were evaluated with serum T4, T3, free T4 (fT4), and TSH concentrations. Thyroid scintigraphy was used as the gold standard to confirm or exclude hyperthyroidism. Median serum TSH concentration in the hyperthyroid cats (hyperthyroid cats had measurable TSH concentrations (≥0.03 ng/mL), whereas 114 (69.9%) of the 163 euthyroid cats had detectable concentrations. Combining serum TSH with T4 or fT4 concentrations lowered the test sensitivity of TSH from 98.0 to 97.0%, but markedly increased overall test specificity (from 69.9 to 98.8%). Serum TSH concentrations are suppressed in 98% of hyperthyroid cats, but concentrations are measurable in a few cats with mild-to-moderate hyperthyroidism. Measurement of serum TSH represents a highly sensitive but poorly specific test for diagnosis of hyperthyroidism and is best measured in combination with T4 and fT4. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  13. The diagnostic sensitivity of dengue rapid test assays is significantly enhanced by using a combined antigen and antibody testing approach.

    Directory of Open Access Journals (Sweden)

    Scott R Fry

    2011-06-01

    Full Text Available BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1 has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum. AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test. METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples. KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6% and 96% (95% CI: 92.2% to 99.8 respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1% and 96.7% specificity (95% CI: 82.8% to 99.9% compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers. CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.

  14. Diagnostic value of tissue polypeptide specific antigen in serum for patients with pancreatic carcinoma

    International Nuclear Information System (INIS)

    Lu Yun; Liu Xingdang; Li Ding; Dei Shouzhen

    2009-01-01

    Objective: To compare the diagnostic value of tissue polypeptide specific antigen (TPS) in serum, with the carbohydrate antigens (CA) 19-9, CA50, CA125 and CA242 in pancreatic carcinoma. Methods: Serum TPS was measured with enzyme linked immunosorbent assay (ELISA). CA19-9 and CA125 were measured with chemiluminescent immunoassay. CAS0 and CA242 were measured with immunoradiometric assay in 33 patients with pancreatitis, 34 patients with pathologically proven pancreatic carcinoma, and 35 patients with non-pancreatic malignancies. Statistic analysis was carried out with SPSS 9.0 software. Results: Patients with pancreatic carcinoma had relatively higher levels of TPS [(386.5 ± 315. 1) U/L] and CA19-9 [(10 820.9 ± 389.7) kU/L] when compared with patients with pancreatitis [(86. 2 ± 28.1) U/L and (61.5 ± 24.7) kU/L, respectively; F = 936. 42, P < 0. 001 ; F = 2217. 09, P < 0. 001], with a sensitivity and a specificity of 70.6% (48/68) and 57.4% (39/68), respectively, for TPS, and 82.4% (28/34) and 77.9% (53/68), respectively, for CA19-9. Diagnostic performance was further improved when TPS was assayed in combination with CA19-9, CA50, CA125 and CA242. Conclusion: Serum TPS has an incremental value in complementing CA19-9 in the diagnosis of pancreatic carcinoma. (authors)

  15. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  16. Model-based versus specific dosimetry in diagnostic context: Comparison of three dosimetric approaches

    Energy Technology Data Exchange (ETDEWEB)

    Marcatili, S., E-mail: sara.marcatili@inserm.fr; Villoing, D.; Mauxion, T.; Bardiès, M. [Inserm, UMR1037 CRCT, Toulouse F-31000, France and Université Toulouse III-Paul Sabatier, UMR1037 CRCT, Toulouse F-31000 (France); McParland, B. J. [Imaging Technology Group, GE Healthcare, Life Sciences, B22U The Grove Centre, White Lion Road, Amersham, England HP7 9LL (United Kingdom)

    2015-03-15

    Purpose: The dosimetric assessment of novel radiotracers represents a legal requirement in most countries. While the techniques for the computation of internal absorbed dose in a therapeutic context have made huge progresses in recent years, in a diagnostic scenario the absorbed dose is usually extracted from model-based lookup tables, most often derived from International Commission on Radiological Protection (ICRP) or Medical Internal Radiation Dose (MIRD) Committee models. The level of approximation introduced by these models may impact the resulting dosimetry. The aim of this work is to establish whether a more refined approach to dosimetry can be implemented in nuclear medicine diagnostics, by analyzing a specific case. Methods: The authors calculated absorbed doses to various organs in six healthy volunteers administered with flutemetamol ({sup 18}F) injection. Each patient underwent from 8 to 10 whole body 3D PET/CT scans. This dataset was analyzed using a Monte Carlo (MC) application developed in-house using the toolkit GATE that is capable to take into account patient-specific anatomy and radiotracer distribution at the voxel level. They compared the absorbed doses obtained with GATE to those calculated with two commercially available software: OLINDA/EXM and STRATOS implementing a dose voxel kernel convolution approach. Results: Absorbed doses calculated with GATE were higher than those calculated with OLINDA. The average ratio between GATE absorbed doses and OLINDA’s was 1.38 ± 0.34 σ (from 0.93 to 2.23). The discrepancy was particularly high for the thyroid, with an average GATE/OLINDA ratio of 1.97 ± 0.83 σ for the six patients. Differences between STRATOS and GATE were found to be higher. The average ratio between GATE and STRATOS absorbed doses was 2.51 ± 1.21 σ (from 1.09 to 6.06). Conclusions: This study demonstrates how the choice of the absorbed dose calculation algorithm may introduce a bias when gamma radiations are of importance, as is

  17. Enteroclysis in adult celiac disease: diagnostic value of specific radiographic features

    International Nuclear Information System (INIS)

    Lomoschitz, F.; Schima, W.; Schober, E.; Turetschek, K.; Kaider, A.; Vogelsang, H.

    2003-01-01

    The purpose of this study was to compare the diagnostic accuracy of various radiographic findings at enteroclysis in adult patients with untreated celiac disease. Twenty-seven adult patients underwent enteroclysis because of unspecific intestinal symptoms before definitive biopsy proof of celiac disease. Enteroclysis of 123 subjects with similar clinical presentation, including abdominal pain, diarrhea, occult intestinal bleeding, and weight loss, who had a definitive diagnosis other than celiac disease, served as controls. The radiographic features previously described in the literature as indicative of adult celiac disease (i.e., fold thickening, decrease of jejunal folds, increase of ileal folds, small bowel dilatation, flocculation) were evaluated in blinded fashion in all studies and the subjective likelihood of diagnosis of celiac disease was assessed. Assessing every finding separately, each feature proved to have a high specificity (78-100%) but low sensitivity (19-59%) for celiac disease. Reversal of jejunoileal fold pattern was the single best feature (specificity 100%, 95% CI 97-100%; sensitivity 59%, 95% CI 40-78%); however, combination of criteria enables establishment of the diagnosis of celiac disease quite accurately (specificity 100%, 95% CI 98-100%; sensitivity 78%, 95% CI 58-91%). Reversal of jejunoileal fold pattern as a single finding as well as combination at least three of the following features, i.e., fold thickening, decrease of jejunal folds (''colonization''), increase of ileal folds (''jejunization''), dilatation, and flocculation, make enteroclysis an accurate tool for diagnosis of celiac disease in adult patients with suspected intestinal disease. (orig.)

  18. Test specification for decant pump and winch assembly

    International Nuclear Information System (INIS)

    Staehr, T.W.

    1994-01-01

    This specification provides the requirements for testing of the vertical turbine decant pump including the floating suction arm with load sensing winch control, instrumentation and the associated PLC/PC control system

  19. Quality assurance of radiopharmaceuticals - specifications and test procedures

    International Nuclear Information System (INIS)

    Baldas, J.; Bonnyman, J.; Colmanet, S.F.; Ivanov, Z.; Lauder, R.A.

    1990-10-01

    The authors report on a Radiopharmaceutical Quality Assurance Test Programme carried out by the Australian Radiation Laboratory in which radiopharmaceuticals used in nuclear medicine in Australia are tested for compliance with specifications. Where the radiopharmaceutical is the subject of a monograph in the British Pharmacopoeia or the European Pharmacopoeia, then the specifications given in the Pharmacopoeia are adopted. In other cases the specifications given have been adopted by this Laboratory and have no legal status. In some cases test procedures described have been taken from various Pharmacopoeias or methods published in the literature. In other cases test methods described have been developed at this Laboratory. It should be noted that, unless stated otherwise, specifications listed apply at all times up until product expire

  20. Detection of lipoarabinomannan as a diagnostic test for tuberculosis.

    OpenAIRE

    Sada, E; Aguilar, D; Torres, M; Herrera, T

    1992-01-01

    A coagglutination technique was established for the detection of lipoarabinomannan of Mycobacterium tuberculosis in human serum samples and evaluated for its utility in the diagnosis of tuberculosis at the Instituto Nacional de Enfermedades Respiratorias in Mexico City. The test had a sensitivity of 88% in patients with sputum-smear-positive active pulmonary tuberculosis. The sensitivity in patients with active pulmonary tuberculosis negative for acid-fast bacilli in sputum was 67%. Less favo...

  1. Diagnostic Role of ECG Recording Simultaneously With EEG Testing.

    Science.gov (United States)

    Kendirli, Mustafa Tansel; Aparci, Mustafa; Kendirli, Nurten; Tekeli, Hakan; Karaoglan, Mustafa; Senol, Mehmet Guney; Togrol, Erdem

    2015-07-01

    Arrhythmia is not uncommon in the etiology of syncope which mimics epilepsy. Data about the epilepsy induced vagal tonus abnormalities have being increasingly reported. So we aimed to evaluate what a neurologist may gain by a simultaneous electrocardiogram (ECG) and electroencephalogram (EEG) recording in the patients who underwent EEG testing due to prediagnosis of epilepsy. We retrospectively evaluated and detected ECG abnormalities in 68 (18%) of 376 patients who underwent EEG testing. A minimum of 20 of minutes artifact-free recording were required for each patient. Standard 1-channel ECG was simultaneously recorded in conjunction with the EEG. In all, 28% of females and 14% of males had ECG abnormalities. Females (mean age 49 years, range 18-88 years) were older compared with the male group (mean age 28 years, range 16-83 years). Atrial fibrillation was more frequent in female group whereas bradycardia and respiratory sinus arrhythmia was higher in male group. One case had been detected a critical asystole indicating sick sinus syndrome in the female group and treated with a pacemaker implantation in the following period. Simultaneous ECG recording in conjunction with EEG testing is a clinical prerequisite to detect and to clarify the coexisting ECG and EEG abnormalities and their clinical relevance. Potentially rare lethal causes of syncope that mimic seizure or those that could cause resistance to antiepileptic therapy could effectively be distinguished by detecting ECG abnormalities coinciding with the signs and abnormalities during EEG recording. © EEG and Clinical Neuroscience Society (ECNS) 2014.

  2. Diagnostic Performance of Tuberculosis-Specific IgG Antibody Profiles in Patients with Presumptive Tuberculosis from Two Continents.

    Science.gov (United States)

    Broger, Tobias; Basu Roy, Robindra; Filomena, Angela; Greef, Charles H; Rimmele, Stefanie; Havumaki, Joshua; Danks, David; Schneiderhan-Marra, Nicole; Gray, Christen M; Singh, Mahavir; Rosenkrands, Ida; Andersen, Peter; Husar, Gregory M; Joos, Thomas O; Gennaro, Maria L; Lochhead, Michael J; Denkinger, Claudia M; Perkins, Mark D

    2017-04-01

    Development of rapid diagnostic tests for tuberculosis is a global priority. A whole proteome screen identified Mycobacterium tuberculosis antigens associated with serological responses in tuberculosis patients. We used World Health Organization (WHO) target product profile (TPP) criteria for a detection test and triage test to evaluate these antigens. Consecutive patients presenting to microscopy centers and district hospitals in Peru and to outpatient clinics at a tuberculosis reference center in Vietnam were recruited. We tested blood samples from 755 HIV-uninfected adults with presumptive pulmonary tuberculosis to measure IgG antibody responses to 57 M. tuberculosis antigens using a field-based multiplexed serological assay and a 132-antigen bead-based reference assay. We evaluated single antigen performance and models of all possible 3-antigen combinations and multiantigen combinations. Three-antigen and multiantigen models performed similarly and were superior to single antigens. With specificity set at 90% for a detection test, the best sensitivity of a 3-antigen model was 35% (95% confidence interval [CI], 31-40). With sensitivity set at 85% for a triage test, the specificity of the best 3-antigen model was 34% (95% CI, 29-40). The reference assay also did not meet study targets. Antigen performance differed significantly between the study sites for 7/22 of the best-performing antigens. Although M. tuberculosis antigens were recognized by the IgG response during tuberculosis, no single antigen or multiantigen set performance approached WHO TPP criteria for clinical utility among HIV-uninfected adults with presumed tuberculosis in high-volume, urban settings in tuberculosis-endemic countries. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  3. Sensitivity and specificity of neuropsychological tests for dementia

    African Journals Online (AJOL)

    specificity of a battery of neuropsychological tests in a sample of elderly persons living in a ... estimate of 20% prevalence for dementia in residential homes ... demographic variables, and mean neuro- psychological .... on optimum balance between sensitivity and specificity (Fig. 1). ..... The lack of stratification of the sample.

  4. The impact of communication barriers on diagnostic confidence and ancillary testing in the emergency department.

    Science.gov (United States)

    Garra, Gregory; Albino, Hiram; Chapman, Heather; Singer, Adam J; Thode, Henry C

    2010-06-01

    Communication barriers (CBs) compromise the diagnostic power of the medical interview and may result in increased reliance on diagnostic tests or incorrect test ordering. The prevalence and degree to which these barriers affect diagnosis, testing, and treatment are unknown. To quantify and characterize CBs encountered in the Emergency Department (ED), and assess the effect of CBs on initial diagnosis and perceived reliance on ancillary testing. This was a prospective survey completed by emergency physicians after initial adult patient encounters. CB severity, diagnostic confidence, and reliance on ancillary testing were quantified on a 100-mm Visual Analog Scale (VAS) from least (0) to most (100). Data were collected on 417 ED patient encounters. CBs were reported in 46%; with a mean severity of 50 mm on a 100-mm VAS with endpoints of "perfect communication and "no communication." Language was the most commonly reported form of CB (28%). More than one CB was identified in 6%. The 100-mm VAS rating of diagnostic confidence was lower in patients with perceived CBs (64 mm) vs. those without CBs (80 mm), p Communication barriers in our ED setting were common, and resulted in lower diagnostic confidence and increased perception that ancillary tests are needed to narrow the diagnosis. Copyright 2010 Elsevier Inc. All rights reserved.

  5. A Test to Express Diagnostic Cohesion of Football Team

    OpenAIRE

    Alexandra O. Savinkina

    2017-01-01

    We proposed to assess the cohesion of a football team by its subject-goal and subject-value unity according to the A.V. Petrovsky theory. Goal unity was measured by the degree of compliance of the priority targets for various players in the team. Values were estimated by the coincidence of the ideas about a perfect football player. On the basis of the provisional diagnosis of the six teams, we had made the lists of goals and values. The tests were piloted on 35 football teams. The results all...

  6. Diagnostics of high-speed liquid lithium jet for IFMIF/EVEDA lithium test loop

    International Nuclear Information System (INIS)

    Kanemura, Takuji; Kondo, Hiroo; Furukawa, Tomohiro; Sugiura, Hirokazu; Horiike, Hiroshi; Yamaoka, Nobuo; Ida, Mizuho; Nakamura, Kazuyuki; Matsushita, Izuru

    2011-01-01

    Regarding R and Ds on the International Fusion Materials Irradiation Facility (IFMIF), hydraulic stability of the liquid Li jet simulating the IFMIF Li target is planned to be validated using EVEDA Li Test Loop (ELTL). IFMIF is an accelerator-based deuteron-lithium (Li) neutron source for research and development of fusion reactor materials. The stable Li target is required in IFMIF to maintain the quality of the neutron fluence and integrity of the Li target itself. This paper presents diagnostics of the Li jet to be implemented in validation tests of the jet stability in ELTL, and those specifications and methodologies are introduced. In the tests, the following physical parameters need to be measured; thickness of the jet; surface structure (height, length/width and frequency of free-surface waves); local flow velocity at the free surface; and Li evaporation rate. With regard to measurement of jet thickness and the surface wave height, a contact-type liquid level sensor is to be used. As for measurement of wave velocity and visual understanding of detailed free-surface structure, a high-speed video camera is to be leveraged. With respect to Li evaporation measurement, weight change of specimens installed near the free surface and frequency change of a crystal quartz are utilized. (author)

  7. How does additional diagnostic testing influence the initial diagnosis in patients with cognitive complaints in a memory clinic setting?

    Science.gov (United States)

    Meijs, Anouk P; Claassen, Jurgen A H R; Rikkert, Marcel G M Olde; Schalk, Bianca W M; Meulenbroek, Olga; Kessels, Roy P C; Melis, René J F

    2015-01-01

    patients suspected of dementia frequently undergo additional diagnostic testing (e.g. brain imaging or neuropsychological assessment) after standard clinical assessment at a memory clinic. This study investigates the use of additional testing in an academic outpatient memory clinic and how it influences the initial diagnosis. the initial diagnosis after standard clinical assessment (history, laboratory tests, cognitive screening and physical and neurological examination) and the final diagnosis after additional testing of 752 memory clinic patients were collected. We specifically registered if, and what type of, additional testing was requested. additional testing was performed in 518 patients (69%), 67% of whom underwent magnetic resonance imaging, 45% had neuropsychological assessment, 14% had cerebrospinal fluid analysis and 49% had (combinations of) other tests. This led to a modification of the initial diagnosis in 17% of the patients. The frequency of change was highest in patients with an initial non-Alzheimer's disease (AD) dementia diagnosis (54%, compared with 11 and 14% in patients with AD and 'no dementia'; P testing 44% was diagnosed with AD, 9% with non-AD dementia and 47% with 'no dementia'. additional testing should especially be considered in non-AD patients. In the large group of patients with an initial AD or 'no dementia' diagnosis, additional tests have little diagnostic impact and may perhaps be used with more restraint. © The Author 2014. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. The MDP skull uptake test: A new diagnostic tool

    International Nuclear Information System (INIS)

    Ell, P.J.; Jarritt, P.H.; Cullum, I.; Lui, D.

    1984-01-01

    An original approach to the measurement of bone turnover is presented. With SPECT, the authors have measured in pgr/ml, the uptake of MDP by the skull in man. The Cleon 710 scanner, ring phantoms and bone biopsies were used for ultimate in vivo/in vitro count recovery correlation and calibration. A normal range for 24 patients was found: 8.5 to 19.5 pgr/ml with a mean of 14. For patients with bony metastases (12), the values were: 22.5 to 50, mean of 30. For 5 patients with osteomalacia, the values were 46 to 68, mean of 62: for 12 patients with hyperparathyroidism, the values were 37 to 48.5, mean of 43. In 3 patients with Pagets disease, the values were 58.5 to 75, with a mean of 65. In 76 patients with metastatic disease to bone, the conventional wholebody bone scan was investigated against the following: 24h wholebody retention of MDP (WBR), skull uptake as described and GFR by Cr-51-DTPA. There is a correlation between GFR and WBR - r=0.67. There is a lesser correlation between GFR and skull uptake - r=0.3. There is no correlation between skull uptake and WBR - r=0.1. The comparison of skull uptake data with normal whole body bone scans leads to a significant proportion of cancer patients with positive skull uptake data. Monostotic disease (especially if metabolic in nature) expresses itself by abnormal skull uptake even if the clinical site of abnormality lies outside the skull. This new technique is ideal as a tool to investigate phosphonate concentration in bone. With it, the authors have shown the effect of specific activity of label on skull uptake, which increases as the specific activity of labelled MDP decreases

  9. Diagnostic value of stool DNA testing for multiple markers of colorectal cancer and advanced adenoma: a meta-analysis.

    Science.gov (United States)

    Yang, Hua; Xia, Bing-Qing; Jiang, Bo; Wang, Guozhen; Yang, Yi-Peng; Chen, Hao; Li, Bing-Sheng; Xu, An-Gao; Huang, Yun-Bo; Wang, Xin-Ying

    2013-08-01

    The diagnostic value of stool DNA (sDNA) testing for colorectal neoplasms remains controversial. To compensate for the lack of large-scale unbiased population studies, a meta-analysis was performed to evaluate the diagnostic value of sDNA testing for multiple markers of colorectal cancer (CRC) and advanced adenoma. The PubMed, Science Direct, Biosis Review, Cochrane Library and Embase databases were systematically searched in January 2012 without time restriction. Meta-analysis was performed using a random-effects model using sensitivity, specificity, diagnostic OR (DOR), summary ROC curves, area under the curve (AUC), and 95% CIs as effect measures. Heterogeneity was measured using the χ(2) test and Q statistic; subgroup analysis was also conducted. A total of 20 studies comprising 5876 individuals were eligible. There was no heterogeneity for CRC, but adenoma and advanced adenoma harboured considerable heterogeneity influenced by risk classification and various detection markers. Stratification analysis according to risk classification showed that multiple markers had a high DOR for the high-risk subgroups of both CRC (sensitivity 0.759 [95% CI 0.711 to 0.804]; specificity 0.883 [95% CI 0.846 to 0.913]; AUC 0.906) and advanced adenoma (sensitivity 0.683 [95% CI 0.584 to 0.771]; specificity 0.918 [95% CI 0.866 to 0.954]; AUC 0.946) but not for the average-risk subgroups of either. In the methylation subgroup, sDNA testing had significantly higher DOR for CRC (sensitivity 0.753 [95% CI 0.685 to 0.812]; specificity 0.913 [95% CI 0.860 to 0.950]; AUC 0.918) and advanced adenoma (sensitivity 0.623 [95% CI 0.527 to 0.712]; specificity 0.926 [95% CI 0.882 to 0.958]; AUC 0.910) compared with the mutation subgroup. There was no significant heterogeneity among studies for subgroup analysis. sDNA testing for multiple markers had strong diagnostic significance for CRC and advanced adenoma in high-risk subjects. Methylation makers had more diagnostic value than mutation

  10. A comprehensive custom panel design for routine hereditary cancer testing: preserving control, improving diagnostics and revealing a complex variation landscape.

    Science.gov (United States)

    Castellanos, Elisabeth; Gel, Bernat; Rosas, Inma; Tornero, Eva; Santín, Sheila; Pluvinet, Raquel; Velasco, Juan; Sumoy, Lauro; Del Valle, Jesús; Perucho, Manuel; Blanco, Ignacio; Navarro, Matilde; Brunet, Joan; Pineda, Marta; Feliubadaló, Lidia; Capellá, Gabi; Lázaro, Conxi; Serra, Eduard

    2017-01-04

    We wanted to implement an NGS strategy to globally analyze hereditary cancer with diagnostic quality while retaining the same degree of understanding and control we had in pre-NGS strategies. To do this, we developed the I2HCP panel, a custom bait library covering 122 hereditary cancer genes. We improved bait design, tested different NGS platforms and created a clinically driven custom data analysis pipeline. The I2HCP panel was developed using a training set of hereditary colorectal cancer, hereditary breast and ovarian cancer and neurofibromatosis patients and reached an accuracy, analytical sensitivity and specificity greater than 99%, which was maintained in a validation set. I2HCP changed our diagnostic approach, involving clinicians and a genetic diagnostics team from panel design to reporting. The new strategy improved diagnostic sensitivity, solved uncertain clinical diagnoses and identified mutations in new genes. We assessed the genetic variation in the complete set of hereditary cancer genes, revealing a complex variation landscape that coexists with the disease-causing mutation. We developed, validated and implemented a custom NGS-based strategy for hereditary cancer diagnostics that improved our previous workflows. Additionally, the existence of a rich genetic variation in hereditary cancer genes favors the use of this panel to investigate their role in cancer risk.

  11. Preliminary design of safety and interlock system for indian test facility of diagnostic neutral beam

    International Nuclear Information System (INIS)

    Tyagi, Himanshu; Soni, Jignesh; Yadav, Ratnakar; Bandyopadhyay, Mainak; Rotti, Chandramouli; Gahlaut, Agrajit; Joshi, Jaydeep; Parmar, Deepak; Bansal, Gourab; Pandya, Kaushal; Chakraborty, Arun

    2016-01-01

    Highlights: • Indian Test Facility being built to characterize DNB for ITER delivery. • Interlock system required to safeguard the investment incurred in building the facility and protecting ITER deliverable components. • Interlock levels upto 3IL-3 identified. • Safety instrumented system for occupational safety being designed. Safety I&C functions of SIL-2 identified. • The systems are based on ITER PIS and PSS design guidelines. - Abstract: Indian Test Facility (INTF) is being built in Institute For Plasma Research to characterize Diagnostic Neutral Beam in co-operation with ITER Organization. INTF is a complex system which consists of several plant systems like beam source, gas feed, vacuum, cryogenics, high voltage power supplies, high power RF generators, mechanical systems and diagnostics systems. Out of these, several INTF components are ITER deliverable, that is, beam source, beam line components and power supplies. To ensure successful operation of INTF involving integrated operation of all the constituent plant systems a matured Data Acquisition and Control System (DACS) is required. The INTF DACS is based on CODAC platform following on PCDH (Plant Control Design Handbook) guidelines. The experimental phases involve application of HV power supplies (100 KV) and High RF power (∼800 KW) which will produce energetic beam of maximum power 6MW within the facility for longer durations. Hence the entire facility will be exposed tohigh heat fluxes and RF radiations. To ensure investment protection and to provide occupational safety for working personnel a matured Safety and Interlock system is required for INTF. The Safety and Interlock systems are high-reliability I&C systems devoted completely to the specific functions. These systems will be separate from the conventional DACS of INTF which will handle the conventional control and acquisition functions. Both, the Safety and Interlock systems are based on IEC 61511 and IEC 61508 standards as

  12. Preliminary design of safety and interlock system for indian test facility of diagnostic neutral beam

    Energy Technology Data Exchange (ETDEWEB)

    Tyagi, Himanshu, E-mail: htyagi@iter-india.org [ITER-India, Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Soni, Jignesh [Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Yadav, Ratnakar; Bandyopadhyay, Mainak; Rotti, Chandramouli [ITER-India, Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Gahlaut, Agrajit [Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Joshi, Jaydeep; Parmar, Deepak [ITER-India, Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India); Bansal, Gourab; Pandya, Kaushal; Chakraborty, Arun [Institute For Plasma Research, Bhat, Gandhinagar, Gujarat (India)

    2016-11-15

    Highlights: • Indian Test Facility being built to characterize DNB for ITER delivery. • Interlock system required to safeguard the investment incurred in building the facility and protecting ITER deliverable components. • Interlock levels upto 3IL-3 identified. • Safety instrumented system for occupational safety being designed. Safety I&C functions of SIL-2 identified. • The systems are based on ITER PIS and PSS design guidelines. - Abstract: Indian Test Facility (INTF) is being built in Institute For Plasma Research to characterize Diagnostic Neutral Beam in co-operation with ITER Organization. INTF is a complex system which consists of several plant systems like beam source, gas feed, vacuum, cryogenics, high voltage power supplies, high power RF generators, mechanical systems and diagnostics systems. Out of these, several INTF components are ITER deliverable, that is, beam source, beam line components and power supplies. To ensure successful operation of INTF involving integrated operation of all the constituent plant systems a matured Data Acquisition and Control System (DACS) is required. The INTF DACS is based on CODAC platform following on PCDH (Plant Control Design Handbook) guidelines. The experimental phases involve application of HV power supplies (100 KV) and High RF power (∼800 KW) which will produce energetic beam of maximum power 6MW within the facility for longer durations. Hence the entire facility will be exposed tohigh heat fluxes and RF radiations. To ensure investment protection and to provide occupational safety for working personnel a matured Safety and Interlock system is required for INTF. The Safety and Interlock systems are high-reliability I&C systems devoted completely to the specific functions. These systems will be separate from the conventional DACS of INTF which will handle the conventional control and acquisition functions. Both, the Safety and Interlock systems are based on IEC 61511 and IEC 61508 standards as

  13. Low specificity of 2 tetanus rapid tests in Cambodia.

    Science.gov (United States)

    Schlumberger, M; Yvonnet, B; Lesage, G; Tep, B

    2015-01-01

    Rapid testing for tetanus on serum or blood allows for an immediate evaluation of individual protection against tetanus in developed countries, using a "single step" immunochromatographic technique using tetanus toxoid. The specificity of these tests, compared to the reference method for tetanus, mouse serum neutralization testing, has however never been assessed in these countries, due to the difficulty to perform serum neutralization titration in mice, because of animal testing bioethical regulations. A collection of sera from adult volunteers in Cambodia, living in rural environment, was tested for tetanus antibodies by ELISA in France, and by mouse serum neutralization in Vietnam. This allowed estimating the sensitivity and specificity of 2 rapid tetanus tests, available on the market: TQS™ and Tetanotop™. The sensitivity of these tests was adequate, compared to mice serum neutralization test, for a test threshold of 0.01 IU/mL, (100% for TQS™, 91% for Tetanotop™), but their specificity was very low (1% for TQS™ and 13% for Tetanotop™). The results prove that these rapid tests for the assessment of individual protection against tetanus should not be used in the adult rural Cambodian population. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. More Than Just Accuracy: A Novel Method to Incorporate Multiple Test Attributes in Evaluating Diagnostic Tests Including Point of Care Tests.

    Science.gov (United States)

    Thompson, Matthew; Weigl, Bernhard; Fitzpatrick, Annette; Ide, Nicole

    2016-01-01

    Current frameworks for evaluating diagnostic tests are constrained by a focus on diagnostic accuracy, and assume that all aspects of the testing process and test attributes are discrete and equally important. Determining the balance between the benefits and harms associated with new or existing tests has been overlooked. Yet, this is critically important information for stakeholders involved in developing, testing, and implementing tests. This is particularly important for point of care tests (POCTs) where tradeoffs exist between numerous aspects of the testing process and test attributes. We developed a new model that multiple stakeholders (e.g., clinicians, patients, researchers, test developers, industry, regulators, and health care funders) can use to visualize the multiple attributes of tests, the interactions that occur between these attributes, and their impacts on health outcomes. We use multiple examples to illustrate interactions between test attributes (test availability, test experience, and test results) and outcomes, including several POCTs. The model could be used to prioritize research and development efforts, and inform regulatory submissions for new diagnostics. It could potentially provide a way to incorporate the relative weights that various subgroups or clinical settings might place on different test attributes. Our model provides a novel way that multiple stakeholders can use to visualize test attributes, their interactions, and impacts on individual and population outcomes. We anticipate that this will facilitate more informed decision making around diagnostic tests.

  15. Diagnostic accuracy of tests to detect hepatitis B surface antigen: a systematic review of the literature and meta-analysis

    Directory of Open Access Journals (Sweden)

    Ali Amini

    2017-11-01

    Full Text Available Abstract Background Chronic Hepatitis B Virus (HBV infection is characterised by the persistence of hepatitis B surface antigen (HBsAg. Expanding HBV diagnosis and treatment programmes into low resource settings will require high quality but inexpensive rapid diagnostic tests (RDTs in addition to laboratory-based enzyme immunoassays (EIAs to detect HBsAg. The purpose of this review is to assess the clinical accuracy of available diagnostic tests to detect HBsAg to inform recommendations on testing strategies in 2017 WHO hepatitis testing guidelines. Methods The systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA guidelines using 9 databases. Two reviewers independently extracted data according to a pre-specified plan and evaluated study quality. Meta-analysis was performed. HBsAg diagnostic accuracy of rapid diagnostic tests (RDTs was compared to enzyme immunoassay (EIA and nucleic-acid test (NAT reference standards. Subanalyses were performed to determine accuracy among brands, HIV-status and specimen type. Results Of the 40 studies that met the inclusion criteria, 33 compared RDTs and/or EIAs against EIAs and 7 against NATs as reference standards. Thirty studies assessed diagnostic accuracy of 33 brands of RDTs in 23,716 individuals from 23 countries using EIA as the reference standard. The pooled sensitivity and specificity were 90.0% (95% CI: 89.1, 90.8 and 99.5% (95% CI: 99.4, 99.5 respectively, but accuracy varied widely among brands. Accuracy did not differ significantly whether serum, plasma, venous or capillary whole blood was used. Pooled sensitivity of RDTs in 5 studies of HIV-positive persons was lower at 72.3% (95% CI: 67.9, 76.4 compared to that in HIV-negative persons, but specificity remained high. Five studies evaluated 8 EIAs against a chemiluminescence immunoassay reference standard with a pooled sensitivity and specificity of 88.9% (95% CI: 87.0, 90.6 and

  16. A rapid, sensitive and reliable diagnostic test for scrub typhus in China

    Directory of Open Access Journals (Sweden)

    Zhang Lijuan

    2011-01-01

    Full Text Available Purpose: To evaluate the performances for detection of IgM and IgG antibodies to Orientia. tsutsugamushi (Ot using a gold conjugate-based rapid diagnostic test (RDT. Materials and Methods: The RDT employing mixture recombinant 56-kDa proteins of O. tsutsugamushi and the mIFA assay was performed on 33 patients from Fujian and Yunnan province respectively and 94 positive sera (36 from Hainan province and 58 from Jiangsu province from convalescent stages of the patients with scrub typhus respectively and 82 negative sera from healthy farmers from Anhui province and Beijing City respectively in 2009. A comparison of the RDT and mIFA assay was performed by using the c2 test and the P level of ≤0.05 was considered to be significant. Results: Among these 94 positive sera from convalescent stages of the illness and 82 sera from control farmers, the specificity of RDT was 100% for both IgM and IgG tests. In 33 cases with scrub typhus, 5 cases were positively detected earlier by RDT than by mIFA for the IgM test, and 2 cases were positive for the IgG test. The sensitivities of RDT were 93.9% and 90.9% for IgM and IgG, respectively. Considering IgM and IgG together, the sensitivity was 100%. The geometric mean titre (GMT of IFA and the RDT assay in diluted sera from confirmed cases were 1:37 versus 1:113 respectively (P<0.001 for IgM test and 1:99 versus 1:279 respectively (P<0.016 for IgG. Conclusions: The RDT was more sensitive than the traditional IFA for the early diagnosis of scrub typhus and was particularly suitable for use in rural areas.

  17. Evaluation of diagnostic tests for Wuchereria bancrofti infection in Brazilian schoolchildren

    Directory of Open Access Journals (Sweden)

    Paula Oliveira

    2014-06-01

    Full Text Available Introduction Since the launch of the Global Programme to Eliminate Lymphatic Filariasis, more than 70% of the endemic countries have implemented mass drug administration (MDA to interrupt disease transmission. The monitoring of filarial infection in sentinel populations, particularly schoolchildren, is recommended to assess the impact of MDA. A key issue is choosing the appropriate tools for these initial assessments (to define the best intervention and for monitoring transmission. Methods This study compared the pre-MDA performance of five diagnostic methods, namely, thick film test, Knott's technique, filtration, Og4C3-ELISA, and the AD12-ICT card test, in schoolchildren from Brazil. Venous and capillary blood samples were collected between 11 pm and 1 am. The microfilarial loads were analyzed with a negative binomial regression, and the prevalence and associated 95% confidence intervals were estimated for all methods. The accuracies of the AD12-ICT card and Og4C3-ELISA tests were assessed against the combination of parasitological test results. Results A total of 805 schoolchildren were examined. The overall and stratified prevalence by age group and gender detected by Og4C3-ELISA and AD12-ICT were markedly higher than the prevalence estimated by the parasitological methods. The sensitivity of the AD12-ICT card and Og4C3-ELISA tests was approximately 100%, and the positive likelihood ratios were above 6. The specificity of the Og4C3-ELISA was higher than that of the AD12-ICT at different prevalence levels. Conclusions The ICT card test should be the recommended tool for monitoring school-age populations living in areas with ongoing or completed MDA.

  18. Optimizing the diagnostic testing of Clostridium difficile infection.

    Science.gov (United States)

    Bouza, Emilio; Alcalá, Luis; Reigadas, Elena

    2016-09-01

    Clostridium difficile infection (CDI) is the leading cause of hospital-acquired diarrhea and is associated with a considerable health and cost burden. However, there is still not a clear consensus on the best laboratory diagnosis approach and a wide variation of testing methods and strategies can be encountered. We aim to review the most practical aspects of CDI diagnosis providing our own view on how to optimize CDI diagnosis. Expert commentary: Laboratory diagnosis in search of C. difficile toxins should be applied to all fecal diarrheic samples reaching the microbiology laboratory in patients > 2 years old, with or without classic risk factors for CDI. Detection of toxins either directly in the fecal sample or in the bacteria isolated in culture confirm CDI in the proper clinical setting. Nuclear Acid Assay techniques (NAAT) allow to speed up the process with epidemiological and therapeutic consequences.

  19. Temperature as a diagnostic for the drift scale test

    International Nuclear Information System (INIS)

    Lin, W; Wagoner, J; Ballard, S

    2000-01-01

    The United States Department of Energy (DOE) is investigating Yucca Mountain, Nevada, for its feasibility as a potential deep geological repository of high-level nuclear waste. In a deep geological repository, the radioactive decay heat released from high-level nuclear waste will heat up the rock mass. The heat will mobilize pore water in the rock mass by evaporation, and even boiling, if the thermal load is great enough. The water vapor/steam will flow away from the heat source because of pressure and thermal gradients and the effects of buoyancy force. The vapor/steam may flow along fractures or highly permeable zones and condense into liquid water in the cooler regions. Gravity and fracture network will control the drainage of the condensed water. Some of the water may flow back toward the waste package and reevaporated. This thermal-hydrological (TH) process will affect the amount of water that may come into contact with the waste package. Water is the main concern for the integrity of the waste package and the waste form, and the potential transport of radioactive nuclides. Thermally driven chemical and mechanical processes may affect the TH process. The coupled thermal-hydrological-mechanical-chemical (THMC) processes need to be understood before the performance of a repository can be adequately predicted. DOE is conducting field thermal tests to provide data for validating the model of the coupled THMC processes. Therefore, understanding the processes revealed by a field thermal test is essential for the model validation. This paper presents examples that temperature measurement is an effective tool for understanding the TH process

  20. The diagnostic value of transrectal ultrasonography combined with prostate specific antigen density in prostate cancer

    International Nuclear Information System (INIS)

    Shen Weidong; Zha Yueqin; Wang Ajun; Hou Jianquan; Ouyang Jun

    2008-01-01

    Objective: To discuss the value of transrectal ultrasound (TRUS) and prostate specific antigen density (PSAD) and prostate specific antigen density of transition zone (PSATZ) for diagnosing prostate cancer. Methods: Chose cases of prostate cancer(PCa) and benign prostate hyperplasia(BPH), each was 19, all the eases were authenticated by pathology. Then compared the characteristic of prostate cancer with prostate specific antigen (PSA) and homologous PSAD, PSATZ. Results: Fourteen cases were discovered by ultrasound among the 19 PCa, the others were only diagnosed as BPH.Among the 14 cases, diffuse pathological changing was found in 1 patient, nodular changing in 13 patients (16 nodules were found). Among the 16 nodules, there were 13 hypoechoic nodules (75%) and 3 hyper echoic or compound echoic nodules (25%), and there were 13 nodules in outer zone and 3 nodules in transition zone.The PSA of PCa and BPH was 8.61-98.65 ng/ml [(48.79±25.34)ng/ml] and 0.58-28.36 ng/ml [(9.73±8.19)ng/ml]. There were no significant differences between the volume of prostate and prostate transition zone (P>0.05), but there were significant differences between the PSAD and PSATZ (P<0.01). That the PCa group was higher than that in the BPH group. Conclusion: It is higher sensitive but bess specific in diagonosis PCa by means of transrectal ultrasound. If it is combined with PSAD and PSATZ, the diagnostic rate of PCa is highly raised. (authors)

  1. Allergic bronchopulmonary aspergillosis in Italian cystic fibrosis patients: Prevalence and percentage of positive tests in the employed diagnostic criteria

    International Nuclear Information System (INIS)

    Taccetti, Giovanni; Procopio, Elena; Marianelli, Lore; Campana, Silvia

    2000-01-01

    The prevalence of allergic bronchopulmonary aspergillosis (ABPA) in cystic fibrosis (CF) patients is difficult to determine because the data in the literature are not homogeneous or comparable. ABPA and CF have similar clinical symptoms which make diagnosis difficult and underestimate the real dimensions of the problem. We conducted an epidemiological study on 3089 Italian CF patients to determine the prevalence of ABPA in Italy and verify the percentage of positive tests in the employed diagnostic criteria. Our results indicate that the prevalence of ABPA in Italian CF patients is 6.18%, mainly in adolescents and young adults. ABPA is diagnosed using clinical symptoms (presence of episodic bronchial obstructions or typical radiographic features) and on the basis of other criteria which can only be partially fulfilled in paediatric patients. Among the diagnostic tests the most sensitive are the total IgE (84.5%), specific IgE anti-Aspergillus fumigatus (81.6%) and the prick test (68.3%). In the absence of clinical symptoms and gold standard diagnostic tests, serological positivity and/or the skin test are not sufficient evidence to confirm the presence of ABPA

  2. Comparative analysis of diagnostic performance, feasibility and cost of different test-methods for thyroid nodules with indeterminate cytology.

    Science.gov (United States)

    Sciacchitano, Salvatore; Lavra, Luca; Ulivieri, Alessandra; Magi, Fiorenza; De Francesco, Gian Paolo; Bellotti, Carlo; Salehi, Leila B; Trovato, Maria; Drago, Carlo; Bartolazzi, Armando

    2017-07-25

    Since it is impossible to recognize malignancy at fine needle aspiration (FNA) cytology in indeterminate thyroid nodules, surgery is recommended for all of them. However, cancer rate at final histology is blood assay.We performed systematic reviews and meta-analyses to compare their features, feasibility, diagnostic performance and cost. GEC, GEC+BRAF, M/F panel+miRNA GEC and M/F panel by NGS were the best in ruling-out malignancy (sensitivity = 90%, 89%, 89% and 90% respectively). BRAF and M/F panel alone and by NGS were the best in ruling-in malignancy (specificity = 100%, 93% and 93%). The M/F by NGS showed the highest accuracy (92%) and BRAF the highest diagnostic odds ratio (DOR) (247). GAL-3-ICC performed well as rule-out (sensitivity = 83%) and rule-in test (specificity = 85%), with good accuracy (84%) and high DOR (27) and is one of the cheapest (113 USD) and easiest one to be performed in different clinical settings.In conclusion, the more accurate molecular-based test-methods are still expensive and restricted to few, highly specialized and centralized laboratories. GAL-3-ICC, although limited by some false negatives, represents the most suitable screening test-method to be applied on a large-scale basis in the diagnostic algorithm of indeterminate thyroid lesions.

  3. 21 CFR 1000.50 - Recommendation for the use of specific area gonad shielding on patients during medical diagnostic...

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Recommendation for the use of specific area gonad shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... GENERAL Radiation Protection Recommendations § 1000.50 Recommendation for the use of specific area gonad...

  4. California mastitis test in the diagnostic of subclinical mastitis

    Directory of Open Access Journals (Sweden)

    Adna Crisléia Rodrigues Monção de Lima

    2013-12-01

    Full Text Available Milk production in Brazil is undoubtedly one of the most important Brazilian agroindustrial complex. Moves large sums of money, the dairy industry employs millions of the people, having potential to provide the domestic and foreign markets. Besides surpassing year by year the index production. The quality of milk is increasingly demanded by consumers and there are bonus programs for milk with low somatic cell counts, which reveal, indirectely, the udder sanity. Mastitis, the udder inflamation, is the main factor that substantially compromises the milk quality. Several methods can diagnose the incidence of subclinical mastitis in dairy herds. One these methods, the California Mastitis Test (CMT has as advantages being practical, low cost and the results are immediately available. The CMT method consists of adding the anionic neutral detergent to a milk sample in order to disrupt milk somatic cell membranes and release nucleic material. The viscousity formed by this reaction allows estimating the number of somatic cells (immunity cells presents in the milk. According to the degree of gelatinization obtained in this reaction, the interpretation of the scores varies from zero, no viscosity, to three crosses, highly viscous. This study was aimed to evaluate the CMT of eight dairy herds of different farms in Sao Paulo state, described by the letters A to H. The scores 1, 2 and 3 were considered positive for subclinical mastitis, while 0 was negative. The results were determined in relative frequency (%. It is evident that the herd D is the most affected by subclinical mastitis, because of the greater number of CMT positive (60%. This may be due to the mismanagement and poor conditions of milking. The properties C, F and G require greater attention, as the result of CMT could corroborate the presence of pathogenic microorganisms and infected cows can quickly transmit the infection to the healthy ones. Note that the farms A, B and H are the ones with

  5. The Impact of Time-Series Diagnostic Tests on the Writing Ability of Iranian EFL Learners

    Science.gov (United States)

    Atashgahi, Bahareh Molazem

    2014-01-01

    This study aimed to show whether administering a battery of time-series diagnostic tests (screening) has any impact on Iranian EFL learners' writing ability. The study was conducted on the intermediate EFL learners at Islamic Azad University North Tehran branch. The researcher administered a homogenizing test in order to exclude the exceptional…

  6. Consensus based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants.

    NARCIS (Netherlands)

    Gardner, I.A.; Nielsen, S.S.; Whittington, R.J.; Collins, M.T.; Bakker, D.; Harris, B.; Sreevatsan, S.; Lombard, J.E.; Sweeney, R.; Smith, D.R.; Gavalchin, J.; Eda, S.

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy studies

  7. Diagnostic value of patient characteristics, history, and six clinical tests for traumatic anterior shoulder instability

    NARCIS (Netherlands)

    van Kampen, D.A.; van den Berg, T.; van der Woude, H.J.; Castelein, R.M.; Terwee, C.B.; Willems, W.J.

    2013-01-01

    Background: It is unknown which combination of patient information and clinical tests might beoptimal for the diagnosis of traumatic anterior shoulder instability. This study aimed to determinethe diagnostic value of individual clinical tests and to develop a prediction model that combined patient

  8. Single and Combined Diagnostic Value of Clinical Features and Laboratory Tests in Acute Appendicitis

    NARCIS (Netherlands)

    Laméris, Wytze; van Randen, Adrienne; Go, Peter M. N. Y. H.; Bouma, Wim H.; Donkervoort, Sandra C.; Bossuyt, Patrick M. M.; Stoker, Jaap; Boermeester, Marja A.

    2009-01-01

    Objectives: The objective was to evaluate the diagnostic accuracy of clinical features and laboratory test results in detecting acute appendicitis. Methods: Clinical features and laboratory test results were prospectively recorded in a consecutive series of 1,101 patients presenting with abdominal

  9. Sensitivity and specificity of the nickel spot (dimethylglyoxime) test.

    Science.gov (United States)

    Thyssen, Jacob P; Skare, Lizbet; Lundgren, Lennart; Menné, Torkil; Johansen, Jeanne D; Maibach, Howard I; Lidén, Carola

    2010-05-01

    The accuracy of the dimethylglyoxime (DMG) nickel spot test has been questioned because of false negative and positive test reactions. The EN 1811, a European standard reference method developed by the European Committee for Standardization (CEN), is fine-tuned to estimate nickel release around the limit value of the EU Nickel Directive from products intended to come into direct and prolonged skin contact. Because assessments according to EN 1811 are expensive to perform, time consuming, and may destruct the test item, it should be of great value to know the accuracy of the DMG screening test. To evaluate the sensitivity and specificity of the DMG test. DMG spot testing, chemical analysis according to the EN 1811 reference method, and X-ray fluorescence spectroscopy (XRF) were performed concomitantly on 96 metallic components from earrings recently purchased in San Francisco. The sensitivity of the DMG test was 59.3% and the specificity was 97.5% based on DMG-test results and nickel release concentrations determined by the EN 1811 reference method. The DMG test has a high specificity but a modest sensitivity. It may serve well for screening purposes. Past exposure studies may have underestimated nickel release from consumer items.

  10. Escalating Health Care Cost due to Unnecessary Diagnostic Testing

    Directory of Open Access Journals (Sweden)

    MUHAMMAD AZAM ISHAQUE CHAUDHARY

    2017-07-01

    Full Text Available Focusing on health care systems can improve health outcomes now and in the future. Growing economies have serious concerns on the rising cost of health, whereas, in under developed countries like Pakistan, it is not emphasized yet at all. The research is conducted to improve a unique aspect of health care systems to provide effective, patient-centred, high-standard health care while maintaining the cost effectiveness. Research is being qualified in two paradigms qualitative and quantitative. In qualitative research, expert?s interviews have been taken to get the basic knowledge of radiology based testing and their prerequisites, in quantitative research ordered are being analysed to check the frequency and if they are unnecessary or qualified medical necessity guidelines as established in qualitative method. Analysis was made on the basis of the trinity relationship of diagnosis, symptoms and respected order to determine the necessity of the order to get its impact on cost of the overall health of those patients and point out more than 50% unnecessary orders are being performed in two government hospitals. The situation is alarming and policy makers should focus on unnecessary ordering to avoid out of pocket expenses and improve quality of care. The research helps in successful application of health care system modifications and policies pertaining to one aspect of health systems, i.e. cost-effectiveness of health care.

  11. Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes

    CERN Document Server

    Cantero, E D; Bravin, E; Sosa, A

    2014-01-01

    We performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a full stroke of 135 mm. A specially designed blade was mounted on the actuator and the transverse positioning of the blade was monitored with a camera-based optical system while moving the actuator at speeds of up to 10 mm/s. The repeatability of the positioning of the blade after several cycles around predefined positions was also measured. The results of the measurements and a general inspection of the device show that the proposed solution fulfils the specifications. A full prototype of short diagnostic box for the HIE-ISOLDE project can now be built for testing.

  12. [Diagnostic advantages of the test system "DS-EIA-HBsAg-0.01" for detection of HBV surface antigen].

    Science.gov (United States)

    Egorova, N I; Pyrenkova, I Iu; Igolkina, S N; Sharipova, I N; Puzyrev, V F; Obriadina, A P; Burkov, A N; Kornienko, N V; Fields, H A; Korovkin, A S; Shalunova, N V; Bektemirov, T A; Kuznetsov, K V; Koshcheeva, N A; Ulanova, T I

    2009-01-01

    The new highly sensitive test system "DS-EIA-HBsAg-0.01" (Priority Certificate No. 2006129019 of August 10, 2006) in detecting hepatitis B surface antigen (HBsAg) was assessed. The sensitivity of the test was estimated using the federal standards sample HBsAg 42-28-311-06, panels' samples Boston Biomedica Inc. (West Bridgewater, Mass, USA) and ZeptoMetrix Corp. (Buffalo, NY, USA). The findings have indicated that "DS-EIA-HBsAg-0.01" is equally effective in detecting different subtypes of HBsAg during a seroconversion period earlier than alternative assays. Along with its high analytical and diagnostic sensitivity, the system shows a high diagnostic specificity.

  13. A vine copula mixed effect model for trivariate meta-analysis of diagnostic test accuracy studies accounting for disease prevalence.

    Science.gov (United States)

    Nikoloulopoulos, Aristidis K

    2017-10-01

    A bivariate copula mixed model has been recently proposed to synthesize diagnostic test accuracy studies and it has been shown that it is superior to the standard generalized linear mixed model in this context. Here, we call trivariate vine copulas to extend the bivariate meta-analysis of diagnostic test accuracy studies by accounting for disease prevalence. Our vine copula mixed model includes the trivariate generalized linear mixed model as a special case and can also operate on the original scale of sensitivity, specificity, and disease prevalence. Our general methodology is illustrated by re-analyzing the data of two published meta-analyses. Our study suggests that there can be an improvement on trivariate generalized linear mixed model in fit to data and makes the argument for moving to vine copula random effects models especially because of their richness, including reflection asymmetric tail dependence, and computational feasibility despite their three dimensionality.

  14. Testing Moral Foundation Theory: Are Specific Moral Emotions Elicited by Specific Moral Transgressions?

    Science.gov (United States)

    Landmann, Helen; Hess, Ursula

    2018-01-01

    Moral foundation theory posits that specific moral transgressions elicit specific moral emotions. To test this claim, participants (N = 195) were asked to rate their emotions in response to moral violation vignettes. We found that compassion and disgust were associated with care and purity respectively as predicted by moral foundation theory.…

  15. Diagnostic test of endometrial cytobrush in cases of perimenopausal and postmenopausal hemorrhage

    Directory of Open Access Journals (Sweden)

    Andrijono Andrijono

    2005-06-01

    Full Text Available Perimenopausal menopausal hemorrhage can be due to by a variety of causative factors. One of its dangerous causes is atypical hyperplasia and endometrial carcinoma. There are a number of risk factors for the occurrence of endometrial carcinoma. The group that has this risk belongs to high-risk group. In this high-risk group, it is necessary to have a method to identify the changes in endometrial abnormality. One of the alternatives is the examination of endometrial cytology. The objective of this study was to evaluate the sensitivity, specificity and correlation test between endometrial cytology and endometrial histology. This study was a diagnostic test of cytological examination of the endometrium as compared with endometrial histology. Endometrial cytology was performed with a modification of cytubrush and IUD shell. Specimen was dissolved into the centrifuged NaCl, and its deposits were then processed for cytological examination with Papanicolaou and Giemsa staining. After the taking of cytology, the process was continued with curettage of the endometrium, and the specimens were processed for cytological examination. Both of them were examined by anatomic pathologist. Statistical analysis used diagnostic test using histological examination of curetage specimens as gold standard. During the period of study 45 study samples were collected, among which 12 (26.66% were endometrial adenocarcinoma, 6 (13.33% with atypical hyperplasia, 11 (24.44% with non-atypical hyperplasia, 15 (33.33% were samples without abnormality, and one sample with endometritis. Actual correlation value was 57.8%, correlation because of possibility 3.38%, and correlation not because of possibility 54.42%, potential correlation not because of possibility 96.62%, and Kappa value 0.56. It was concluded that cytological examination of the endometriurn with cytobrush could be employed as a screening method in the abnormalities of endometrial thickness, with

  16. Diagnostic test pepsinogen I and combination with tumor marker CEA in gastric cancer

    Science.gov (United States)

    Sembiring, J.; Sarumpaet, K.; Ganie, R. A.

    2018-03-01

    Gastric cancer (GC) is the fifth leading cause of cancer and the third leading cause of cancer-related mortality globally. Human pepsinogens (HP) are considered promising serological biomarkers for the screening of atrophic gastritis (AG) and GC. HP are biochemically and immunochemically classified into two groups: pepsinogen I (PG I) and PG II. Carcinoembryonic antigen (CEA) is a glycoprotein, which is present in normal mucosal cells but increased amounts are associated with adenocarcinoma, especially colorectal cancer. CEA in combination with other tumour markers can be used in pre-operative staging and thereby assist in the planning of the type of surgery required and future management options. The purpose of this study was to diagnose test PG I and combination with tumor marker CEA in 32 patients suspected with GC. There was a significant difference in levels of CEA between GC group with non-GC with a value p <0.001. PGI sensitivity was 70.58% and specificity 93.3%. The sensitivity of PGI and CEA combination of 94.1% and specificity 80%. The area of AUC obtained was 92.7% at 95% confidence interval (82.7-100%). This AUC value indicated that the value of diagnostic accuracy of the PGI and CEA combinations of 92.7%.

  17. Enteroclysis in adult celiac disease: diagnostic value of specific radiographic features

    Energy Technology Data Exchange (ETDEWEB)

    Lomoschitz, F.; Schima, W.; Schober, E.; Turetschek, K. [Department of Radiology and Ludwig Boltzmann Institute for Clinical and Experimental Radiologic Research, University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Kaider, A. [Department of Medical Computer Sciences, University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Vogelsang, H. [Department of Internal Medicine IV, Division of Gastroenterology, University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)

    2003-04-01

    The purpose of this study was to compare the diagnostic accuracy of various radiographic findings at enteroclysis in adult patients with untreated celiac disease. Twenty-seven adult patients underwent enteroclysis because of unspecific intestinal symptoms before definitive biopsy proof of celiac disease. Enteroclysis of 123 subjects with similar clinical presentation, including abdominal pain, diarrhea, occult intestinal bleeding, and weight loss, who had a definitive diagnosis other than celiac disease, served as controls. The radiographic features previously described in the literature as indicative of adult celiac disease (i.e., fold thickening, decrease of jejunal folds, increase of ileal folds, small bowel dilatation, flocculation) were evaluated in blinded fashion in all studies and the subjective likelihood of diagnosis of celiac disease was assessed. Assessing every finding separately, each feature proved to have a high specificity (78-100%) but low sensitivity (19-59%) for celiac disease. Reversal of jejunoileal fold pattern was the single best feature (specificity 100%, 95% CI 97-100%; sensitivity 59%, 95% CI 40-78%); however, combination of criteria enables establishment of the diagnosis of celiac disease quite accurately (specificity 100%, 95% CI 98-100%; sensitivity 78%, 95% CI 58-91%). Reversal of jejunoileal fold pattern as a single finding as well as combination at least three of the following features, i.e., fold thickening, decrease of jejunal folds (''colonization''), increase of ileal folds (''jejunization''), dilatation, and flocculation, make enteroclysis an accurate tool for diagnosis of celiac disease in adult patients with suspected intestinal disease. (orig.)

  18. The diagnostic test accuracy of ultrasound for the detection of lateral epicondylitis: a systematic review and meta-analysis.

    Science.gov (United States)

    Latham, S K; Smith, T O

    2014-05-01

    The purpose of this study was to determine the diagnostic test accuracy of ultrasound for the detection of lateral epicondylitis. An electronic search of databases registering published (MEDLINE, EMBASE, CINAHL, AMED, Cochrane Library, ScienceDirect) and unpublished literature was conducted to January 2013. All diagnostic accuracy studies that compared the accuracy of ultrasound (index test) with a reference standard for lateral epicondylitis were included. The methodological quality of each of the studies was appraised using the QUADAS tool. When appropriate, the pooled sensitivity and specificity analysis was conducted. Ten studies investigating 711 participants and 1077 elbows were included in this review. Ultrasound had variable sensitivity and specificity (sensitivity: 64%-100%; specificity: 36%-100%). The available literature had modest methodological quality, and was limited in terms of sample sizes and blinding between index and reference test results. There is evidence to support the use of ultrasound in the detection of lateral epicondylitis. However, its accuracy appears to be highly dependent on numerous variables, such as operator experience, equipment and stage of pathology. Judgement should be used when considering the benefit of ultrasound for use in clinical practice. Further research assessing variables such a transducer frequency independently is specifically warranted. Level II. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. Pre-examination factors affecting molecular diagnostic test results and interpretation: A case-based approach.

    Science.gov (United States)

    Payne, Deborah A; Baluchova, Katarina; Peoc'h, Katell H; van Schaik, Ron H N; Chan, K C Allen; Maekawa, Masato; Mamotte, Cyril; Russomando, Graciela; Rousseau, François; Ahmad-Nejad, Parviz

    2017-04-01

    Multiple organizations produce guidance documents that provide opportunities to harmonize quality practices for diagnostic testing. The International Organization for Standardization ISO 15189 standard addresses requirements for quality in management and technical aspects of the clinical laboratory. One technical aspect addresses the complexities of the pre-examination phase prior to diagnostic testing. The Committee for Molecular Diagnostics of the International Federation for Clinical Chemistry and Laboratory Medicine (also known as, IFCC C-MD) conducted a survey of international molecular laboratories and determined ISO 15189 to be the most referenced guidance document. In this review, the IFCC C-MD provides case-based examples illustrating the value of select pre-examination processes as these processes relate to molecular diagnostic testing. Case-based examples in infectious disease, oncology, inherited disease and pharmacogenomics address the utility of: 1) providing information to patients and users, 2) designing requisition forms, 3) obtaining informed consent and 4) maintaining sample integrity prior to testing. The pre-examination phase requires extensive and consistent communication between the laboratory, the healthcare provider and the end user. The clinical vignettes presented in this paper illustrate the value of applying select ISO 15189 recommendations for general laboratory to the more specialized area of Molecular Diagnostics. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Optimal Sequential Diagnostic Strategy Generation Considering Test Placement Cost for Multimode Systems

    Directory of Open Access Journals (Sweden)

    Shigang Zhang

    2015-10-01

    Full Text Available Sequential fault diagnosis is an approach that realizes fault isolation by executing the optimal test step by step. The strategy used, i.e., the sequential diagnostic strategy, has great influence on diagnostic accuracy and cost. Optimal sequential diagnostic strategy generation is an important step in the process of diagnosis system construction, which has been studied extensively in the literature. However, previous algorithms either are designed for single mode systems or do not consider test placement cost. They are not suitable to solve the sequential diagnostic strategy generation problem considering test placement cost for multimode systems. Therefore, this problem is studied in this paper. A formulation is presented. Two algorithms are proposed, one of which is realized by system transformation and the other is newly designed. Extensive simulations are carried out to test the effectiveness of the algorithms. A real-world system is also presented. All the results show that both of them have the ability to solve the diagnostic strategy generation problem, and they have different characteristics.

  1. Optimal Sequential Diagnostic Strategy Generation Considering Test Placement Cost for Multimode Systems

    Science.gov (United States)

    Zhang, Shigang; Song, Lijun; Zhang, Wei; Hu, Zheng; Yang, Yongmin

    2015-01-01

    Sequential fault diagnosis is an approach that realizes fault isolation by executing the optimal test step by step. The strategy used, i.e., the sequential diagnostic strategy, has great influence on diagnostic accuracy and cost. Optimal sequential diagnostic strategy generation is an important step in the process of diagnosis system construction, which has been studied extensively in the literature. However, previous algorithms either are designed for single mode systems or do not consider test placement cost. They are not suitable to solve the sequential diagnostic strategy generation problem considering test placement cost for multimode systems. Therefore, this problem is studied in this paper. A formulation is presented. Two algorithms are proposed, one of which is realized by system transformation and the other is newly designed. Extensive simulations are carried out to test the effectiveness of the algorithms. A real-world system is also presented. All the results show that both of them have the ability to solve the diagnostic strategy generation problem, and they have different characteristics. PMID:26457709

  2. Shoulder pain in primary care: diagnostic accuracy of clinical examination tests for non-traumatic acromioclavicular joint pain

    Science.gov (United States)

    2013-01-01

    Background Despite numerous methodological flaws in previous study designs and the lack of validation in primary care populations, clinical tests for identifying acromioclavicular joint (ACJ) pain are widely utilised without concern for such issues. The aim of this study was to estimate the diagnostic accuracy of traditional ACJ tests and to compare their accuracy with other clinical examination features for identifying a predominant ACJ pain source in a primary care cohort. Methods Consecutive patients with shoulder pain were recruited prospectively from primary health care clinics. Following a standardised clinical examination and diagnostic injection into the subacromial bursa, all participants received a fluoroscopically guided diagnostic block of 1% lidocaine hydrochloride (XylocaineTM) into the ACJ. Diagnostic accuracy statistics including sensitivity, specificity, predictive values, positive and negative likelihood ratios (LR+ and LR-) were calculated for traditional ACJ tests (Active Compression/O’Brien’s test, cross-body adduction, localised ACJ tenderness and Hawkins-Kennedy test), and for individual and combinations of clinical examination variables that were associated with a positive anaesthetic response (PAR) (P≤0.05) defined as 80% or more reduction in post-injection pain intensity during provocative clinical tests. Results Twenty two of 153 participants (14%) reported an 80% PAR. None of the traditional ACJ tests were associated with an 80% PAR (P0.05). Five clinical examination variables (repetitive mechanism of pain onset, no referred pain below the elbow, thickened or swollen ACJ, no symptom provocation during passive glenohumeral abduction and external rotation) were associated with an 80% PAR (P<0.05) and demonstrated an ability to accurately discriminate between an PAR and NAR (AUC 0.791; 95% CI 0.702, 0.880; P<0.001). Less than two positive clinical features resulted in 96% sensitivity (95% CI 0.78, 0.99) and a LR- 0.09 (95% CI 0.02, 0

  3. Bayesian analysis of longitudinal Johne's disease diagnostic data without a gold standard test

    DEFF Research Database (Denmark)

    Wang, C.; Turnbull, B.W.; Nielsen, Søren Saxmose

    2011-01-01

    the posterior estimates of the model parameters that provide the basis for inference concerning the accuracy of the diagnostic procedure. Based on the Bayesian approach, the posterior probability distribution of the change-point onset time can be obtained and used as a criterion for infection diagnosis......-point process with a Weibull survival hazard function was used to model the progression of the hidden disease status. The model adjusted for the fixed effects of covariate variables and random effects of subject on the diagnostic testing procedure. Markov chain Monte Carlo methods were used to compute....... An application is presented to an analysis of ELISA and fecal culture test outcomes in the diagnostic testing of paratuberculosis (Johne's disease) for a Danish longitudinal study from January 2000 to March 2003. The posterior probability criterion based on the Bayesian model with 4 repeated observations has...

  4. Confirming nasogastric tube placement: Is the colorimeter as sensitive and specific as X-ray? A diagnostic accuracy study.

    Science.gov (United States)

    Mordiffi, Siti Zubaidah; Goh, Mien Li; Phua, Jason; Chan, Yiong-Huak

    2016-09-01

    The effect of delivering enteral nutrition or medications via a nasogastric tube that is inadvertently located in the tracheobronchial tract can cause respiratory complications. Although radiographic examination is accepted as the gold standard for confirming the position of patients' enteral tubes, it is costly, involves risks of radiation, and is not failsafe. Studies using carbon dioxide sensors to detect inadvertent nasogastric tube placements have been conducted in intensive care settings. However, none involved patients in general wards. The objective of this study was to ascertain the diagnostic measure of colorimeter, with radiographic examination as the reference standard, to confirm the location of nasogastric tubes in patients. A prospective observational study of a diagnostic test. This study was conducted in the general wards of an approximately 1100-bed acute care tertiary hospital of an Academic Medical Center in Singapore. Adult patients with nasogastric tubes admitted to the general wards were recruited into the study. The colorimeter was attached to the nasogastric tube to detect for the presence of carbon dioxide, suggestive of a tracheobronchial placement. The exact location of the nasogastric tube was subsequently confirmed by a radiographic examination. A total of 192 tests were undertaken. The colorimeter detected carbon dioxide in 29 tested nasogastric tubes, of which radiographic examination confirmed that four tubes were located in the tracheobronchial tract. The colorimeter failed to detect carbon dioxide in one nasogastric tube that was located in the tracheobronchial tract, thus, demonstrating a sensitivity of 0.80 [95% CI (0.376, 0.964)]. The colorimeter detected absence of carbon dioxide in 163 tested nasogastric tubes in which radiographic examination confirmed 160 gastrointestinal and one tracheobronchial placements, demonstrating a specificity of 0.865 [95% CI (0.808, 0.907)]. The colorimeter detected one tracheobronchial

  5. Development and testing of a diagnostic system for intelligen distributed control at EBR-2

    International Nuclear Information System (INIS)

    Edwards, R.M.; Ruhl, D.W.; Klevans, E.H.; Robinson, G.E.

    1990-01-01

    A diagnostic system is under development for demonstration of Intelligent Distributed Control at the Experimental Breeder Reactor (EBR--II). In the first phase of the project a diagnostic system is being developed for the EBR-II steam plant based on the DISYS expert systems approach. Current testing uses recorded plant data and data from simulated plant faults. The dynamical simulation of the EBR-II steam plant uses the Babcock and Wilcox (B ampersand W) Modular Modeling System (MMS). At EBR-II the diagnostic system operates in the UNIX workstation and receives live plant data from the plant Data Acquisition System (DAS). Future work will seek implementation of the steam plant diagnostic in a distributed manner using UNIX based computers and Bailey microprocessor-based control system. 10 refs., 6 figs

  6. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    Science.gov (United States)

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally

  7. A novel bedside diagnostic test for methanol poisoning using dry chemistry for formate.

    Science.gov (United States)

    Hovda, Knut Erik; Gadeholt, Gaut; Evtodienko, Vladimir; Jacobsen, Dag

    2015-11-01

    The standard diagnostic approach to methanol poisoning is chromatographic measurement of methanol on centrally placed stationary equipment. Methanol poisoning in places where such equipment is unavailable is thus often not diagnosed. Methanol is metabolized to a toxic metabolite, formate; the presence of this compound indicates methanol poisoning. We have developed an enzymatic test for formate and modified it into a portable dry chemistry system that could be used anywhere. The method consists of two enzymatic steps: Formation of NADH from NAD by formate dehydrogenase, and subsequent use of NADH as a reductant of a tetrazolium into a formazan dye that can be quantified photometrically or visually. The photometer gave a good correlation of R(2) = 0.9893 in serum and R(2) = 0.9949 in whole blood, showing an instrumental detection limit of less than 1 mM (4.5 mg/dL). The visual readings showed a correlation of R(2) = 0.8966. Users experienced some difficulty in separating the negative control from the low positives. We have documented the feasibility of an affordable formate strip test for bedside diagnosis of methanol poisoning and for screening of metabolic acidosis of unknown origin. Visual reading is possible, but a reader will improve reliability at lower levels of formate. Future studies are necessary to study the sensitivity and specificity towards other causes of metabolic acidosis and other acids present in human blood.

  8. Novel speed test for evaluation of badminton specific movements

    DEFF Research Database (Denmark)

    Madsen, Christian Møller; Karlsen, Anders; Nybo, Lars

    2015-01-01

    In this study we developed a novel badminton speed test (BST). The test was designed to mimic match play. The test starts in the center of the court and consists of five maximal actions to sensors located in each of the four corners of the court. The 20 actions are performed in randomized order...... as dictated by computer screen shots displayed one second following completion of the previous action. We assessed day-to-day variation in elite players and specificity of the test was evaluated by comparing 30 meter sprint performance and time to complete the BST in 20 elite, 21 skilled players and 20 age...

  9. Evaluating the accuracy of molecular diagnostic testing for canine visceral leishmaniasis using latent class analysis.

    Directory of Open Access Journals (Sweden)

    Manuela da Silva Solcà

    Full Text Available Host tissues affected by Leishmania infantum have differing degrees of parasitism. Previously, the use of different biological tissues to detect L. infantum DNA in dogs has provided variable results. The present study was conducted to evaluate the accuracy of molecular diagnostic testing (qPCR in dogs from an endemic area for canine visceral leishmaniasis (CVL by determining which tissue type provided the highest rate of parasite DNA detection. Fifty-one symptomatic dogs were tested for CVL using serological, parasitological and molecular methods. Latent class analysis (LCA was performed for accuracy evaluation of these methods. qPCR detected parasite DNA in 100% of these animals from at least one of the following tissues: splenic and bone marrow aspirates, lymph node and skin fragments, blood and conjunctival swabs. Using latent variable as gold standard, the qPCR achieved a sensitivity of 95.8% (CI 90.4-100 in splenic aspirate; 79.2% (CI 68-90.3 in lymph nodes; 77.3% (CI 64.5-90.1 in skin; 75% (CI 63.1-86.9 in blood; 50% (CI 30-70 in bone marrow; 37.5% (CI 24.2-50.8 in left-eye; and 29.2% (CI 16.7-41.6 in right-eye conjunctival swabs. The accuracy of qPCR using splenic aspirates was further evaluated in a random larger sample (n = 800, collected from dogs during a prevalence study. The specificity achieved by qPCR was 76.7% (CI 73.7-79.6 for splenic aspirates obtained from the greater sample. The sensitivity accomplished by this technique was 95% (CI 93.5-96.5 that was higher than those obtained for the other diagnostic tests and was similar to that observed in the smaller sampling study. This confirms that the splenic aspirate is the most effective type of tissue for detecting L. infantum infection. Additionally, we demonstrated that LCA could be used to generate a suitable gold standard for comparative CVL testing.

  10. Acute diverticulitis of the sigmoid colon: value of ultrasound as an initial diagnostic test

    International Nuclear Information System (INIS)

    Garcia-Aguayo, F. J.; Gil, P. M.

    2002-01-01

    To assess the value of ultrasound as an initial diagnostic method in cases of acute diverticulitis. Ultrasound was carried out in 76 patients with a clinical diagnosis of acute sigmoid diverticulitis. The final diagnosis was based on the clinical course in every case, as well as on computed tomography (CT; n=46), histopathological examination (n=10), colonoscopy (n=4) and barium enema (n=2). The diagnostic criteria established for ultrasound was a thickening of the sigmoid colon wall of >4 mm and the presence of a least one of the following features: diverticular, phlegmon or abscess. The CT diagnosis was based on two indispensable findings: thickening of the sigmoid colon of>4 mm and inflammation of pericolonic fat. The final diagnosis was acute diverticulitis in 52 patients, some other disease in 18 and undetermined in 6. The sensitivities of ultrasound and CT were 81% and 94%, respectively, and their specificities were 79% and 83%, respectively. Of the 10 false negatives on ultrasound, seven corresponded to cases of simple diverticulitis and three to cases of complicated diverticulitis (two in patients with abscess and one in a patient with pneumoperitoneum). CT provided the correct diagnosis in eight of these cases, and resulted in false negatives in two cases of mild diverticulitis. Ultrasound is a valid test in the initial diagnosis of acute diverticulitis of the sigmoid colon. CT should be performed when ultrasound fails to provide a diagnosis or in cases of negative results when there is a strong clinical suspicion of diverticulitis, as well as when the possibility of complicated diverticulitis exists. (Author) 14 refs

  11. Comparison of cow-side diagnostic tests for subclinical mastitis of dairy cows in Musanze district, Rwanda.

    Science.gov (United States)

    Iraguha, Blaise; Hamudikuwanda, Humphrey; Mushonga, Borden; Kandiwa, Erick; Mpatswenumugabo, Jean P

    2017-06-21

    Four subclinical mastitis diagnostic tests (the UdderCheck® test [a lactate dehydrogenasebased test], the California Mastitis Test [CMT], the Draminski® test [a conductivity-based test] and the PortaSCC® test [a portable somatic cell count-based test]) were compared in a study comprising crossbreed dairy cows (n = 30) during September and October 2015. Sensitivity and specificity of the CMT, Draminski® and UdderCheck® tests were compared with the PortaSCC® as reference. The CMT, Draminski® and UdderCheck® test results were compared with the results of the PortaSCC® test using kappa statistics. Duplicate quarter milk samples (n = 120) were concurrently subjected to the four tests. Sensitivity and specificity were 88.46% and 86.17% (CMT), 78.5% and 81.4% (Draminski®) and 64.00% and 78.95% (UdderCheck®). The CMT showed substantial agreement (k = 0.66), the Draminski® test showed moderate agreement (k = 0.48) and the UdderCheck® test showed fair agreement (k = 0.37) with the PortaSCC® test and positive likelihood ratios were 6.40, 4.15 and 3.04, respectively. The cow-level subclinical mastitis prevalence was 70%, 60%, 60% and 56.7% for PortaSCC®, CMT, Draminski® and UdderCheck® tests, respectively. At udder quarter level, subclinical mastitis prevalence was 20%, 21.67% and 20.83% for PortaSCC®, CMT and UdderCheck®, respectively. A correlation (P < 0.05) and moderate strength of association were found between the four tests used. The study showed that compared to the PortaSCC® test, the CMT was the most preferable option, followed by the Draminski® test, while the UdderCheck® test was the least preferable option for subclinical mastitis screening.

  12. Comparison of cow-side diagnostic tests for subclinical mastitis of dairy cows in Musanze district, Rwanda

    Directory of Open Access Journals (Sweden)

    Blaise Iraguha

    2017-06-01

    Full Text Available Four subclinical mastitis diagnostic tests (the UdderCheck® test [a lactate dehydrogenasebased test], the California Mastitis Test [CMT], the Draminski® test [a conductivity-based test] and the PortaSCC® test [a portable somatic cell count-based test] were compared in a study comprising crossbreed dairy cows (n = 30 during September and October 2015. Sensitivity and specificity of the CMT, Draminski® and UdderCheck® tests were compared with the PortaSCC® as reference. The CMT, Draminski® and UdderCheck® test results were compared with the results of the PortaSCC® test using kappa statistics. Duplicate quarter milk samples (n = 120 were concurrently subjected to the four tests. Sensitivity and specificity were 88.46% and 86.17% (CMT, 78.5% and 81.4% (Draminski® and 64.00% and 78.95% (UdderCheck®. The CMT showed substantial agreement (k = 0.66, the Draminski® test showed moderate agreement (k = 0.48 and the UdderCheck® test showed fair agreement (k = 0.37 with the PortaSCC® test and positive likelihood ratios were 6.40, 4.15 and 3.04, respectively. The cow-level subclinical mastitis prevalence was 70%, 60%, 60% and 56.7% for PortaSCC®, CMT, Draminski® and UdderCheck® tests, respectively. At udder quarter level, subclinical mastitis prevalence was 20%, 21.67% and 20.83% for PortaSCC®, CMT and UdderCheck®, respectively. A correlation (P < 0.05 and moderate strength of association were found between the four tests used. The study showed that compared to the PortaSCC® test, the CMT was the most preferable option, followed by the Draminski® test, while the UdderCheck® test was the least preferable option for subclinical mastitis screening.

  13. Comparative evaluation of two rapid field tests for malaria diagnosis: Partec Rapid Malaria Test® and Binax Now® Malaria Rapid Diagnostic Test.

    Science.gov (United States)

    Nkrumah, Bernard; Acquah, Samuel Ek; Ibrahim, Lukeman; May, Juergen; Brattig, Norbert; Tannich, Egbert; Nguah, Samuel Blay; Adu-Sarkodie, Yaw; Huenger, Frank

    2011-05-23

    About 90% of all malaria deaths in sub-Saharan Africa occur in children under five years. Fast and reliable diagnosis of malaria requires confirmation of the presence of malaria parasites in the blood of patients with fever or history suggestive of malaria; hence a prompt and accurate diagnosis of malaria is the key to effective disease management. Confirmation of malaria infection requires the availability of a rapid, sensitive, and specific testing at an affordable cost. We compared two recent methods (the novel Partec Rapid Malaria Test® (PT) and the Binax Now® Malaria Rapid Diagnostic Test (BN RDT) with the conventional Giemsa stain microscopy (GM) for the diagnosis of malaria among children in a clinical laboratory of a hospital in a rural endemic area of Ghana. Blood samples were collected from 263 children admitted with fever or a history of fever to the pediatric clinic of the Agogo Presbyterian Hospital. The three different test methods PT, BN RDT and GM were performed independently by well trained and competent laboratory staff to assess the presence of malaria parasites. Results were analyzed and compared using GM as the reference standard. In 107 (40.7%) of 263 study participants, Plasmodium sp. was detected by GM. PT and BN RDT showed positive results in 111 (42.2%) and 114 (43.4%), respectively. Compared to GM reference standard, the sensitivities of the PT and BN RDT were 100% (95% CI: 96.6-100) and 97.2% (95% CI: 92.0-99.4), respectively, specificities were 97.4% (95% CI: 93.6-99.3) and 93.6% (95% CI: 88.5-96.9), respectively. There was a strong agreement (kappa) between the applied test methods (GM vs PT: 0.97; p < 0.001 and GM vs BN RDT: 0.90; p < 0.001). The average turnaround time per tests was 17 minutes. In this study two rapid malaria tests, PT and BN RDT, demonstrated a good quality of their performance compared to conventional GM. Both methods require little training, have short turnaround times, are applicable as well as affordable and

  14. Systematic review, meta-analysis and economic modelling of molecular diagnostic tests for antibiotic resistance in tuberculosis.

    Science.gov (United States)

    Drobniewski, Francis; Cooke, Mary; Jordan, Jake; Casali, Nicola; Mugwagwa, Tendai; Broda, Agnieszka; Townsend, Catherine; Sivaramakrishnan, Anand; Green, Nathan; Jit, Mark; Lipman, Marc; Lord, Joanne; White, Peter J; Abubakar, Ibrahim

    2015-05-01

    introducing rapid molecular testing (in addition to culture and drug sensitivity testing). Probabilistic sensitivity analysis was performed to evaluate the impact on cost-effectiveness of diagnostic and treatment time delays, diagnosis and treatment costs, and associated QALYs. A total of 8922 titles and abstracts were identified, with 557 papers being potentially eligible. Of these, 56 studies contained sufficient test information for analysis. All three commercial tests performed well when detecting drug resistance in clinical samples, although with evidence of heterogeneity between studies. Pooled sensitivity for GenoType® MTBDRplus (Hain Lifescience, Nehren, Germany) (isoniazid and rifampicin resistance), INNO-LiPA Rif.TB® (Fujirebio Europe, Ghent, Belgium) (rifampicin resistance) and Xpert® MTB/RIF (Cepheid Inc., Sunnyvale, CA, USA) (rifampicin resistance) was 83.4%, 94.6%, 95.4% and 96.8%, respectively; equivalent pooled specificity was 99.6%, 98.2%, 99.7% and 98.4%, respectively. Results of the transmission model suggest that all of the rapid assays considered here, if added to the current diagnostic pathway, would be cost-saving and achieve a reduction in expected QALY loss compared with current practice. GenoType MTBDRplus appeared to be the most cost-effective of the rapid tests in the South Asian population, although results were similar for GeneXpert. In all other scenarios GeneXpert appeared to be the most cost-effective strategy. Rapid molecular tests for rifampicin and isoniazid resistance were sensitive and specific. They may also be cost-effective when added to culture drug susceptibility testing in the UK. There is global interest in point-of-care testing and further work is needed to review the performance of emerging tests and the wider health-economic impact of decentralised testing in clinics and primary care, as well as non-health-care settings, such as shelters and prisons. This study is registered as PROSPERO CRD42011001537. The National Institute

  15. Systematic review, meta-analysis and economic modelling of molecular diagnostic tests for antibiotic resistance in tuberculosis.

    Science.gov (United States)

    Drobniewski, Francis; Cooke, Mary; Jordan, Jake; Casali, Nicola; Mugwagwa, Tendai; Broda, Agnieszka; Townsend, Catherine; Sivaramakrishnan, Anand; Green, Nathan; Jit, Mark; Lipman, Marc; Lord, Joanne; White, Peter J; Abubakar, Ibrahim

    2015-01-01

    economic model was used to evaluate the cost-effectiveness of introducing rapid molecular testing (in addition to culture and drug sensitivity testing). Probabilistic sensitivity analysis was performed to evaluate the impact on cost-effectiveness of diagnostic and treatment time delays, diagnosis and treatment costs, and associated QALYs. RESULTS A total of 8922 titles and abstracts were identified, with 557 papers being potentially eligible. Of these, 56 studies contained sufficient test information for analysis. All three commercial tests performed well when detecting drug resistance in clinical samples, although with evidence of heterogeneity between studies. Pooled sensitivity for GenoType® MTBDRplus (Hain Lifescience, Nehren, Germany) (isoniazid and rifampicin resistance), INNO-LiPA Rif.TB® (Fujirebio Europe, Ghent, Belgium) (rifampicin resistance) and Xpert® MTB/RIF (Cepheid Inc., Sunnyvale, CA, USA) (rifampicin resistance) was 83.4%, 94.6%, 95.4% and 96.8%, respectively; equivalent pooled specificity was 99.6%, 98.2%, 99.7% and 98.4%, respectively. Results of the transmission model suggest that all of the rapid assays considered here, if added to the current diagnostic pathway, would be cost-saving and achieve a reduction in expected QALY loss compared with current practice. GenoType MTBDRplus appeared to be the most cost-effective of the rapid tests in the South Asian population, although results were similar for GeneXpert. In all other scenarios GeneXpert appeared to be the most cost-effective strategy. CONCLUSIONS Rapid molecular tests for rifampicin and isoniazid resistance were sensitive and specific. They may also be cost-effective when added to culture drug susceptibility testing in the UK. There is global interest in point-of-care testing and further work is needed to review the performance of emerging tests and the wider health-economic impact of decentralised testing in clinics and primary care, as well as non-health-care settings, such as shelters and

  16. The Mini-Mental State Examination as a diagnostic and screening test for delirium: systematic review and meta-analysis.

    Science.gov (United States)

    Mitchell, Alex J; Shukla, Deepak; Ajumal, Hafsa A; Stubbs, Brendon; Tahir, Tayyeb A

    2014-01-01

    To analyse the evidence concerning the accuracy of the Mini-Mental State Examination (MMSE) as a diagnostic and screening test for the presence of delirium in adults. Two authors searched MEDLINE, PsychINFO and EMBASE from inception till March 2014. Articles were included that investigated the diagnostic validity of the MMSE to detect delirium against standardised criteria. A diagnostic validity meta-analysis was conducted. Thirteen studies were included representing 2017 patients in medical settings of whom 29.4% had delirium. The meta-analysis revealed the MMSE had an overall sensitivity and specificity estimate of 84.1% and 73.0%, but this was 81.1% and 82.8% in a subgroup analysis involving robust high quality studies. Sensitivity was unchanged but specificity was 68.4% (95% CI = 50.9-83.5%) in studies using a predefined cutoff of <24 to signify a case. In high-risk samples where delirium was present in 25% of patients, then the Positive predictive value and Negative predictive value would be 50.9% (48.3-66.2%) and 93.2% (90.0-96.5%). The MMSE cannot be recommended as a case-finding confirmatory test of delirium, but may be used as an initial screen to rule out high scorers who are unlikely to have delirium with approximately 93% accuracy. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Subsurface barrier demonstration test strategy and performance specification

    International Nuclear Information System (INIS)

    Treat, R.L.; Cruse, J.M.

    1994-05-01

    This document was developed to help specify a major demonstration test project of subsurface barrier systems supporting the Tank Waste Remediation System (TWRS) Program. The document focuses discussion on requirements applicable to demonstration of three subsurface barrier concepts: (1) Injected Material, (2) Cryogenic, and (3) Desiccant. Detailed requirements are provided for initial qualification of a technology proposal followed by the pre-demonstration and demonstration test requirements and specifications. Each requirement and specification is accompanied by a discussion of the rationale for it. The document also includes information on the Hanford Site tank farms and related data; the related and currently active technology development projects within the DOE's EM-50 Program; and the overall demonstration test strategy. Procurement activities and other preparations for actual demonstration testing are on hold until a decision is made regarding further development of subsurface barriers. Accordingly, this document is being issued for information only

  18. Evaluating eosin-5-maleimide binding as a diagnostic test for hereditary spherocytosis in newborn infants.

    Science.gov (United States)

    Christensen, R D; Agarwal, A M; Nussenzveig, R H; Heikal, N; Liew, M A; Yaish, H M

    2015-05-01

    Neonates with undiagnosed hereditary spherocytosis (HS) are at risk for developing hazardous hyperbilirubinemia and anemia. Making an early diagnosis of HS in a neonate can prompt anticipatory guidance to prevent these adverse outcomes. A recent comparison study showed that a relatively new diagnostic test for HS, eosin-5-maleimide (EMA)-flow cytometry, performs better than other available tests in confirming HS. However, reports have not specifically examined the performance of this test among neonates. We compared EMA-flow cytometry from blood samples of healthy control neonates vs samples from neonates suspected of having HS on the basis of severe Coombs-negative jaundice and spherocytes on blood film. The diagnosis of HS was later either confirmed or excluded based on clinical findings and next generation sequencing (NGS) after which we correlated the EMA-flow results with the diagnosis. EMA-flow was performed on the blood of 31 neonates; 20 healthy term newborns and 11 who were suspected of having HS. Eight of the 11 were later confirmed positive for HS and one was confirmed positive for hereditary elliptocytosis (HE). All nine had persistently abnormal erythroid morphology, reticulocytosis and anemia, and eight of the nine had relevant mutations discovered using NGS. The other was confirmed positive for HS on the basis that a parent had HS, and the neonate's spherocytosis, reticulocytosis and anemia persisted. The 20 healthy controls and the 2 in whom HS was initially suspected but later excluded all had EMA-flow results in the range reported in healthy children and adults. In contrast, all nine in whom HS or HE was confirmed had abnormal EMA-flow results consistent with previous reports in older children and adults with HS. Although our sample size is small, our findings are consistent with the literature in older children and adults suggesting that EMA-flow cytometric testing performs well in supporting the diagnosis of HS/HE during the early neonatal

  19. Decision making about healthcare-related tests and diagnostic test strategies. Paper 2: a review of methodological and practical challenges

    NARCIS (Netherlands)

    Mustafa, Reem A.; Wiercioch, Wojtek; Cheung, Adrienne; Prediger, Barbara; Brozek, Jan; Bossuyt, Patrick; Garg, Amit X.; Lelgemann, Monika; Büehler, Diedrich; Schünemann, Holger J.

    2017-01-01

    Objectives: In this first of a series of five articles, we provide an overview of how and why healthcare-related tests and diagnostic strategies are currently applied. We also describe how our findings can be integrated with existing frameworks for making decisions that guide the use of

  20. Towards Modernizing the Characterization of Shock and Detonation Physics Performance via Novel Diagnostics and Tests

    Science.gov (United States)

    Salyer, Terry

    2017-06-01

    For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.

  1. Specification and acceptance testing of radiotherapy treatment planning systems

    International Nuclear Information System (INIS)

    2007-04-01

    Quality assurance (QA) in the radiation therapy treatment planning process is essential to ensure accurate dose delivery to the patient and to minimize the possibility of accidental exposure. The computerized radiotherapy treatment planning systems (RTPSs) are now widely available in industrialized and developing countries and it is of special importance to support hospitals in Member States in developing procedures for acceptance testing, commissioning and QA of their RTPSs. Responding to these needs, a group of experts developed an IAEA publication with such recommendations, which was published in 2004 as IAEA Technical Reports Series No. 430. This report provides a general framework and describes a large number of tests and procedures that should be considered by the users of new RTPSs. However, small hospitals with limited resources or large hospitals with high patient load and limited staff are not always able to perform complete characterization, validation and software testing of algorithms used in RTPSs. Therefore, the IAEA proposed more specific guidelines that provide a step-by-step recommendation for users at hospitals or cancer centres how to implement acceptance and commissioning procedures for newly purchased RTPSs. The current publication was developed in the framework of the Coordinated Research Project on Development of Procedures for Quality Assurance for Dosimetry Calculations in Radiotherapy and uses the International Electrotechnical Commission (IEC) standard IEC 62083, Requirements for the Safety of Radiotherapy Treatment Planning Systems as its basis. The report addresses the procedures for specification and acceptance testing of RTPSs to be used by both manufacturers and users at the hospitals. Recommendations are provided for specific tests to be performed at the manufacturing facility known as type tests, and for acceptance tests to be performed at the hospital known as site tests. The purpose of acceptance testing is to demonstrate to the

  2. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.

    Science.gov (United States)

    Plebani, Mario

    2017-07-01

    An important priority in the current healthcare scenario should be to address errors in laboratory testing, which account for a significant proportion of diagnostic errors. Efforts made in laboratory medicine to enhance the diagnostic process have been directed toward improving technology, greater volumes and more accurate laboratory tests being achieved, but data collected in the last few years highlight the need to re-evaluate the total testing process (TTP) as the unique framework for improving quality and patient safety. Valuable quality indicators (QIs) and extra-analytical performance specifications are required for guidance in improving all TTP steps. Yet in literature no data are available on extra-analytical performance specifications based on outcomes, and nor is it possible to set any specification using calculations involving biological variability. The collection of data representing the state-of-the-art based on quality indicators is, therefore, underway. The adoption of a harmonized set of QIs, a common data collection and standardised reporting method is mandatory as it will not only allow the accreditation of clinical laboratories according to the International Standard, but also assure guidance for promoting improvement processes and guaranteeing quality care to patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  3. Serum biomarkers reflecting specific tumor tissue remodeling processes are valuable diagnostic tools for lung cancer

    International Nuclear Information System (INIS)

    Willumsen, Nicholas; Bager, Cecilie L; Leeming, Diana J; Smith, Victoria; Christiansen, Claus; Karsdal, Morten A; Dornan, David; Bay-Jensen, Anne-Christine

    2014-01-01

    Extracellular matrix (ECM) proteins, such as collagen type I and elastin, and intermediate filament (IMF) proteins, such as vimentin are modified and dysregulated as part of the malignant changes leading to disruption of tissue homeostasis. Noninvasive biomarkers that reflect such changes may have a great potential for cancer. Levels of matrix metalloproteinase (MMP) generated fragments of type I collagen (C1M), of elastin (ELM), and of citrullinated vimentin (VICM) were measured in serum from patients with lung cancer (n = 40), gastrointestinal cancer (n = 25), prostate cancer (n = 14), malignant melanoma (n = 7), chronic obstructive pulmonary disease (COPD) (n = 13), and idiopathic pulmonary fibrosis (IPF) (n = 10), as well as in age-matched controls (n = 33). The area under the receiver operating characteristics (AUROC) was calculated and a diagnostic decision tree generated from specific cutoff values. C1M and VICM were significantly elevated in lung cancer patients as compared with healthy controls (AUROC = 0.98, P < 0.0001) and other cancers (AUROC = 0.83 P < 0.0001). A trend was detected when comparing lung cancer with COPD+IPF. No difference could be seen for ELM. Interestingly, C1M and VICM were able to identify patients with lung cancer with a positive predictive value of 0.9 and an odds ratio of 40 (95% CI = 8.7–186, P < 0.0001). Biomarkers specifically reflecting degradation of collagen type I and citrullinated vimentin are applicable for lung cancer patients. Our data indicate that biomarkers reflecting ECM and IMF protein dysregulation are highly applicable in the lung cancer setting. We speculate that these markers may aid in diagnosing and characterizing patients with lung cancer

  4. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  5. Decision making about healthcare-related tests and diagnostic test strategies. Paper 2: a review of methodological and practical challenges.

    Science.gov (United States)

    Mustafa, Reem A; Wiercioch, Wojtek; Cheung, Adrienne; Prediger, Barbara; Brozek, Jan; Bossuyt, Patrick; Garg, Amit X; Lelgemann, Monika; Büehler, Diedrich; Schünemann, Holger J

    2017-12-01

    In this first of a series of five articles, we provide an overview of how and why healthcare-related tests and diagnostic strategies are currently applied. We also describe how our findings can be integrated with existing frameworks for making decisions that guide the use of healthcare-related tests and diagnostic strategies. We searched MEDLINE, references of identified articles, chapters in relevant textbooks, and identified articles citing classic literature on this topic. We provide updated frameworks for the potential roles and applications of tests with suggested definitions and practical examples. We also discuss study designs that are commonly used to assess tests' performance and the effects of tests on people's health. These designs include diagnostic randomized controlled trials and retrospective validation. We describe the utility of these and other currently suggested designs, which questions they can answer and which ones they cannot. In addition, we summarize the challenges unique to decision-making resulting from the use of tests. This overview highlights current challenges in the application of tests in decision-making in healthcare, provides clarifications, and informs the proposed solutions. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Utilization of genetic tests: analysis of gene-specific billing in Medicare claims data.

    Science.gov (United States)

    Lynch, Julie A; Berse, Brygida; Dotson, W David; Khoury, Muin J; Coomer, Nicole; Kautter, John

    2017-08-01

    We examined the utilization of precision medicine tests among Medicare beneficiaries through analysis of gene-specific tier 1 and 2 billing codes developed by the American Medical Association in 2012. We conducted a retrospective cross-sectional study. The primary source of data was 2013 Medicare 100% fee-for-service claims. We identified claims billed for each laboratory test, the number of patients tested, expenditures, and the diagnostic codes indicated for testing. We analyzed variations in testing by patient demographics and region of the country. Pharmacogenetic tests were billed most frequently, accounting for 48% of the expenditures for new codes. The most common indications for testing were breast cancer, long-term use of medications, and disorders of lipid metabolism. There was underutilization of guideline-recommended tumor mutation tests (e.g., epidermal growth factor receptor) and substantial overutilization of a test discouraged by guidelines (methylenetetrahydrofolate reductase). Methodology-based tier 2 codes represented 15% of all claims billed with the new codes. The highest rate of testing per beneficiary was in Mississippi and the lowest rate was in Alaska. Gene-specific billing codes significantly improved our ability to conduct population-level research of precision medicine. Analysis of these data in conjunction with clinical records should be conducted to validate findings.Genet Med advance online publication 26 January 2017.

  7. PBF/LOFT Lead Rod Test Program experiment operating specification

    International Nuclear Information System (INIS)

    Varacalle, D.J. Jr.

    1978-11-01

    The PBF/LOFT Lead Rod (LLR) Test Program is being conducted to provide experimental information on the behavior of nuclear fuel under normal and accident conditions in the Power Burst Facility at the Idaho National Engineering Laboratory. Understanding the behavior of light-water reactors (LWR) under loss-of-coolant conditions is a major objective of the NRC Reactor Safety Research Program. The Loss of Fluid Test (LOFT) facility is the major testing facility to evaluate the systems response of an LWR over a wide range of Loss of Coolant Experment (LOCE) conditions. As such, the LOFT core is intended to be used for sequential LOCE tests provided no significant fuel rod failures occur. The PFB/LLR tests are designed to simulate the test conditions for the LOFT Power Ascension Tests L2-2 through L2-5. The test program has been designed to provide a parametric evaluation of the LOFT fuel over a wide range of power. Thus, a relatively accurate assessment of the state of the LOFT core after the completion of each subtest and the anticipated effect of the next test can be obtained by utilizing a combination of LLR test data and analytical predictions. Specifications for the test program are presented

  8. Diagnostic Validity of Combining History Elements and Physical Examination Tests for Traumatic and Degenerative Symptomatic Meniscal Tears.

    Science.gov (United States)

    Décary, Simon; Fallaha, Michel; Frémont, Pierre; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Feldman, Debbie E; Sylvestre, Marie-Pierre; Vendittoli, Pascal-André; Desmeules, François

    2017-10-27

    The current approach to the clinical diagnosis of traumatic and degenerative symptomatic meniscal tears (SMTs) proposes combining history elements and physical examination tests without systematic prescription of imaging investigations, yet the evidence to support this diagnostic approach is scarce. To assess the validity of diagnostic clusters combining history elements and physical examination tests to diagnose or exclude traumatic and degenerative SMT compared with other knee disorders. Prospective diagnostic accuracy study. Patients were recruited from 2 orthopedic clinics, 2 family medicine clinics, and from a university community. A total of 279 consecutive patients who underwent consultation for a new knee complaint. Each patient was assessed independently by 2 evaluators. History elements and standardized physical examination tests performed by a physiotherapist were compared with the reference standard: an expert physicians' composite diagnosis including a clinical examination and confirmatory magnetic resonance imaging. Participating expert physicians were orthopedic surgeons (n = 3) or sport medicine physicians (n = 2). Penalized logistic regression (least absolute shrinkage and selection operator) was used to identify history elements and physical examination tests associated with the diagnosis of SMT and recursive partitioning was used to develop diagnostic clusters. Diagnostic accuracy measures were calculated including sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios (LR+/-) with associated 95% confidence intervals (CIs). Eighty patients had a diagnosis of SMT (28.7%), including 35 traumatic tears and 45 degenerative tears. The combination a history of trauma during a pivot, medial knee pain location, and a positive medial joint line tenderness test was able to diagnose (LR+ = 8.9; 95% CI 6.1-13.1) or exclude (LR- = 0.10; 95% CI 0.03-0.28) a traumatic SMT. Combining a history of

  9. Appraising and applying evidence about a diagnostic test during a performance-based assessment

    Directory of Open Access Journals (Sweden)

    Franklin Ellen

    2004-10-01

    Full Text Available Abstract Background The practice of Evidence-based Medicine requires that clinicians assess the validity of published research and then apply the results to patient care. We wanted to assess whether our soon-to-graduate medical students could appraise and apply research about a diagnostic test within a clinical context and to compare our students with peers trained at other institutions. Methods 4th year medical students who previously had demonstrated competency at probability revision and just starting first-year Internal Medicine residents were used for this research. Following an encounter with a simulated patient, subjects critically appraised a paper about an applicable diagnostic test and revised the patient's pretest probability given the test result. Results The medical students and residents demonstrated similar skills at critical appraisal, correctly answering 4.7 and 4.9, respectively, of 6 questions (p = 0.67. Only one out of 28 (3% medical students and none of the 15 residents were able to correctly complete the probability revision task (p = 1.00. Conclusions This study found that most students completing medical school are able to appraise an article about a diagnostic test but few are able to apply the information from the article to a patient. These findings raise questions about the clinical usefulness of the EBM skills possessed by graduating medical students within the area of diagnostic testing.

  10. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Full Text Available Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Resumo: Objetivo: Avaliar o teste QuickVue® RSV Test Kit (QUIDEL Corp, CA, EUA para o diagn

  11. Test of 1D carbon-carbon composite prototype tiles for the SPIDER diagnostic calorimeter

    Science.gov (United States)

    Serianni, G.; Pimazzoni, A.; Canton, A.; Palma, M. Dalla; Delogu, R.; Fasolo, D.; Franchin, L.; Pasqualotto, R.; Tollin, M.

    2017-08-01

    Additional heating will be provided to the thermonuclear fusion experiment ITER by injection of neutral beams from accelerated negative ions. In the SPIDER test facility, under construction at Consorzio RFX in Padova (Italy), the production of negative ions will be studied and optimised. To this purpose the STRIKE (Short-Time Retractable Instrumented Kalorimeter Experiment) diagnostic will be used to characterise the SPIDER beam during short operation (several seconds) and to verify if the beam meets the ITER requirement regarding the maximum allowed beam non-uniformity (below ±10%). The most important measurements performed by STRIKE are beam uniformity, beamlet divergence and stripping losses. The major components of STRIKE are 16 1D-CFC (Carbon matrix-Carbon Fibre reinforced Composite) tiles, observed at the rear side by a thermal camera. The requirements of the 1D CFC material include a large thermal conductivity along the tile thickness (at least 10 times larger than in the other directions); low specific heat and density; uniform parameters over the tile surface; capability to withstand localised heat loads resulting in steep temperature gradients. So 1D CFC is a very anisotropic and delicate material, not commercially available, and prototypes are being specifically realised. This contribution gives an overview of the tests performed on the CFC prototype tiles, aimed at verifying their thermal behaviour. The spatial uniformity of the parameters and the ratio between the thermal conductivities are assessed by means of a power laser at Consorzio RFX. Dedicated linear and non-linear simulations are carried out to interpret the experiments and to estimate the thermal conductivities; these simulations are described and a comparison of the experimental data with the simulation results is presented.

  12. Yield and cost of individual common diagnostic tests in new primary care outpatients in Japan.

    Science.gov (United States)

    Takemura, Yuzuru; Ishida, Haku; Inoue, Yuji; Beck, J Robert

    2002-01-01

    Appropriate diagnostic testing involves considerations of cost-effectiveness. We examined the cost-effectiveness of individual tests in a panel of tests defined by the Japan Society of Clinical Pathology. We studied 540 new, symptomatic primary care outpatients with a set of 30 common diagnostic tests [the Essential Laboratory Tests (2); ELT(2) panel] for clinical evaluation and identification of occult disease. A useful result (UR) of testing was defined as a finding that contributed to a change in a physician's diagnosis or decision-making relating to a "tentative initial diagnosis" obtained from history and physical examination alone. The ELT(2) panel testing yielded 398 URs and uncovered 261 occult diseases among 540 patients. In total, 1592 tests contributed to either UR-generation or discovery of occult disease. The cost per effective test (cost required per test that contributed to either definition of effectiveness) ranged from 108 yen (approximately 0.92 US dollars) for total cholesterol to 6200 yen (approximately 52.50 dollars) for chest x-ray. Contribution rates and the cost per effective test varied among disease categories. We restructured panel components considering the effectiveness of each test. Subsets of the ELT(2) would have improved cost-effectiveness and achieved cost savings in five of eight disease categories. Assembly of tests based on cost-effectiveness can improve clinical efficiency and decrease total cost of panel testing for selected patient groups.

  13. Plasma diagnostic development and UHV testing for the ALPHA collaboration at Marquette University

    Science.gov (United States)

    Tharp, T. D.; Alpha Collaboration

    2017-10-01

    At Marquette, we are developing the next generation of nonneutral plasma diagnostics for the ALPHA experiment at CERN. ALPHA is building a new vertical experiment to test the gravitational interaction of antihydrogen with Earth. This expansion requires significant changes to the design of our plasma diagnostic suites: the next generation of tools must be able to measure plasmas from two directions, and must be capable of operating in a horizontal position. The diagnostic suite includes measurements of plasma density, shape, and temperature. The hardware used includes a MicroChannel Plate (MCP), a Faraday Cup, and an electron gun. In addition, we are building a vacuum chamber to test the viability of 3-d printed components for UHV compatibility, with target pressures of 10-10 mbar.

  14. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  15. Evaluation of molecular markers for Phytophthora ramorum detection and identification: Testing for specificity using a standardized library of isolates

    Science.gov (United States)

    F.N. Martin; M.D. Coffey; K. Zeller; R.C. Hamelin; P. Tooley; M. Garbelotto; K.J.D. Hughes; T. Kubisiak; G.J. Bilodeau; L. Levy; C. Blomquist; P.H. Berger

    2009-01-01

    Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World...

  16. Diagnostic accuracy of a two-item Drug Abuse Screening Test (DAST-2).

    Science.gov (United States)

    Tiet, Quyen Q; Leyva, Yani E; Moos, Rudolf H; Smith, Brandy

    2017-11-01

    Drug use is prevalent and costly to society, but individuals with drug use disorders (DUDs) are under-diagnosed and under-treated, particularly in primary care (PC) settings. Drug screening instruments have been developed to identify patients with DUDs and facilitate treatment. The Drug Abuse Screening Test (DAST) is one of the most well-known drug screening instruments. However, similar to many such instruments, it is too long for routine use in busy PC settings. This study developed and validated a briefer and more practical DAST for busy PC settings. We recruited 1300 PC patients in two Department of Veterans Affairs (VA) clinics. Participants responded to a structured diagnostic interview. We randomly selected half of the sample to develop and the other half to validate the new instrument. We employed signal detection techniques to select the best DAST items to identify DUDs (based on the MINI) and negative consequences of drug use (measured by the Inventory of Drug Use Consequences). Performance indicators were calculated. The two-item DAST (DAST-2) was 97% sensitive and 91% specific for DUDs in the development sample and 95% sensitive and 89% specific in the validation sample. It was highly sensitive and specific for DUD and negative consequences of drug use in subgroups of patients, including gender, age, race/ethnicity, marital status, educational level, and posttraumatic stress disorder status. The DAST-2 is an appropriate drug screening instrument for routine use in PC settings in the VA and may be applicable in broader range of PC clinics. Published by Elsevier Ltd.

  17. Procurement specification high vacuum test chamber and pumping system

    International Nuclear Information System (INIS)

    1976-01-01

    The specification establishes requirements for a high-vacuum test chamber, associated vacuum pumps, valves, controls, and instrumentation that shall be designed and fabricated for use as a test chamber for testing a closed loop Brayton Isotope Power System (BIPS) Ground Demonstration System (GDS). The vacuum system shall include all instrumentation required for pressure measurement and control of the vacuum pumping system. A general outline of the BIPS-GDS in the vacuum chamber and the preliminary piping and instrumentation interface to the vacuum chamber are shown

  18. Identification student’s misconception of heat and temperature using three-tier diagnostic test

    Science.gov (United States)

    Suliyanah; Putri, H. N. P. A.; Rohmawati, L.

    2018-03-01

    The objective of this research is to develop a Three-Tier Diagnostic Test (TTDT) to identify the student's misconception of heat and temperature. Stages of development include: analysis, planning, design, development, evaluation and revise. The results of this study show that (1) the quality of the three-tier type diagnostic test instrument developed has been expressed well with the following details: (a) Internal validity of 88.19% belonging to the valid category. (b) External validity of empirical construct validity test using Pearson Product Moment obtained 0.43 is classified and result of empirical construct validity test obtained false positives 6.1% and false negatives 5.9% then the instrument was valid. (c) Test reliability by using Cronbach’s Alpha of 0.98 which means acceptable. (d) The 80% difficulty level test is quite difficult. (2) Student misconceptions on the temperature of heat and displacement materials based on the II test the highest (84%), the lowest (21%), and the non-misconceptions (7%). (3) The highest cause of misconception among students is associative thinking (22%) and the lowest is caused by incomplete or incomplete reasoning (11%). Three-Tier Diagnostic Test (TTDT) could identify the student's misconception of heat and temperature.

  19. 40 CFR 798.5195 - Mouse biochemical specific locus test.

    Science.gov (United States)

    2010-07-01

    ...-induced variants are bred to determine the genetic nature of the change. (f) Data and reports—(1... SUBSTANCES CONTROL ACT (CONTINUED) HEALTH EFFECTS TESTING GUIDELINES Genetic Toxicity § 798.5195 Mouse...) A biochemical specific locus mutation is a genetic change resulting from a DNA lesion causing...

  20. Comparison of liver fibrosis blood tests developed for HCV with new specific tests in HIV/HCV co-infection.

    Science.gov (United States)

    Calès, Paul; Halfon, Philippe; Batisse, Dominique; Carrat, Fabrice; Perré, Philippe; Penaranda, Guillaume; Guyader, Dominique; d'Alteroche, Louis; Fouchard-Hubert, Isabelle; Michelet, Christian; Veillon, Pascal; Lambert, Jérôme; Weiss, Laurence; Salmon, Dominique; Cacoub, Patrice

    2010-08-01

    We compared 5 non-specific and 2 specific blood tests for liver fibrosis in HCV/HIV co-infection. Four hundred and sixty-seven patients were included into derivation (n=183) or validation (n=284) populations. Within these populations, the diagnostic target, significant fibrosis (Metavir F > or = 2), was found in 66% and 72% of the patients, respectively. Two new fibrosis tests, FibroMeter HICV and HICV test, were constructed in the derivation population. Unadjusted AUROCs in the derivation population were: APRI: 0.716, Fib-4: 0.722, Fibrotest: 0.778, Hepascore: 0.779, FibroMeter: 0.783, HICV test: 0.822, FibroMeter HICV: 0.828. AUROCs adjusted on classification and distribution of fibrosis stages in a reference population showed similar values in both populations. FibroMeter, FibroMeter HICV and HICV test had the highest correct classification rates in F0/1 and F3/4 (which account for high predictive values): 77-79% vs. 70-72% in the other tests (p=0.002). Reliable individual diagnosis based on predictive values > or = 90% distinguished three test categories: poorly reliable: Fib-4 (2.4% of patients), APRI (8.9%); moderately reliable: Fibrotest (25.4%), FibroMeter (26.6%), Hepascore (30.2%); acceptably reliable: HICV test (40.2%), FibroMeter HICV (45.6%) (ptests). FibroMeter HICV classified all patients into four reliable diagnosis intervals ( or =F1, > or =F2) with an overall accuracy of 93% vs. 79% (pfibrosis. Tests designed for HCV infections are less effective in HIV/HCV infections. A specific test, like FibroMeter HICV, was the most interesting test for diagnostic accuracy, correct classification profile, and a reliable diagnosis. With reliable diagnosis intervals, liver biopsy can therefore be avoided in all patients. Copyright 2010 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  1. Standard Specification for Solar Simulation for Terrestrial Photovoltaic Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This specification provides means for classifying solar simulators intended for indoor testing of photovoltaic devices (solar cells or modules), according to their spectral match to a reference spectral irradiance, non-uniformity of spatial irradiance, and temporal instability of irradiance. 1.2 Testing of photovoltaic devices may require the use of solar simulators. Test Methods that require specific classification of simulators as defined in this specification include Test Methods E948, E1036, and E1362. 1.3 This standard is applicable to both pulsed and steady state simulators and includes recommended test requirements used for classifying such simulators. 1.4 A solar simulator usually consists of three major components: (1) light source(s) and associated power supply; (2) any optics and filters required to modify the output beam to meet the classification requirements in Section 4; and (3) the necessary controls to operate the simulator, adjust irradiance, etc. 1.5 A light source that does not mee...

  2. Critical evaluation of a badminton-specific endurance test.

    Science.gov (United States)

    Fuchs, Michael; Faude, Oliver; Wegmann, Melissa; Meyer, Tim

    2014-03-01

    To overcome the limitations of traditional 1-dimensional fitness tests in analyzing physiological properties of badminton players, a badminton-specific endurance test (BST) was created. This study aimed at analyzing the influence of various fitness dimensions on BST performance. 18 internationally competing male German badminton players (22.4 ± 3.2 y, 79.2 ± 7.7 kg, 1.84 ± 0.06 m, world-ranking position [WRP] 21-501) completed a straight-sprint test, a change-of-direction speed test, various jump tests (countermovement jump, drop jump, standing long jump), a multistage running test (MST), and the BST. During this on-court field test players have to respond to a computerized sign indicating direction and speed of badminton-specific movements by moving into the corresponding corners. Significant correlations were found between performance in MST and BST (individual anaerobic threshold [IAT], r = .63, P = .005; maximum velocity [Vmax], r = .60, P = .009). A negative correlation (r = -.59, P = .014) was observed between IAT in BST and drop-jump contact time. No further associations between performance indices could be detected. Apart from a small portion explained by MST results (IAT, R2 = .40; Vmax, R2 = .36), the majority of BST performance cannot be explained by the determined physiological correlates. Moreover, it was impossible to predict the WRP of a player on the basis of BST results (r = -.15, P = .55). Neither discipline-specific performance nor basic physiological properties were appropriately reflected by a BST in elite badminton players. This does not substantiate its validity for regular use as a testing tool. However, it may be useful for monitoring on-court training sessions.

  3. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  4. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  5. Portuguese Family Physicians' Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Luísa Sá

    Full Text Available Physicians' ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests.A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician's level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician's cost estimate was compared with the true cost and the absolute error was calculated.One-quarter (24%; 95% confidence interval: 23%-25% of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53-56 overestimating and 21% (95% IC: 20-22 underestimating the true actual cost. The majority (76% of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82% said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain.Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care.

  6. Portuguese Family Physicians’ Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study

    Science.gov (United States)

    Sá, Luísa; Costa-Santos, Cristina; Teixeira, Andreia; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto; Santos, Paulo; Martins, Carlos

    2015-01-01

    Background Physicians’ ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests. Methods A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician’s level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician’s cost estimate was compared with the true cost and the absolute error was calculated. Results One-quarter (24%; 95% confidence interval: 23%–25%) of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53–56) overestimating and 21% (95% IC: 20–22) underestimating the true actual cost. The majority (76%) of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82%) said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain. Conclusions Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care. PMID:26356625

  7. Comparative field performance and adherence to test results of four malaria rapid diagnostic tests among febrile patients more than five years of age in Blantyre, Malawi

    Directory of Open Access Journals (Sweden)

    San Joaquin Miguel

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostics tests (RDTs can increase availability of laboratory-based diagnosis and improve the overall management of febrile patients in malaria endemic areas. In preparation to scale-up RDTs in health facilities in Malawi, an evaluation of four RDTs to help guide national-level decision-making was conducted. Methods A cross sectional study of four histidine rich-protein-type-2- (HRP2 based RDTs at four health centres in Blantyre, Malawi, was undertaken to evaluate the sensitivity and specificity of RDTs, assess prescriber adherence to RDT test results and explore operational issues regarding RDT implementation. Three RDTs were evaluated in only one health centre each and one RDT was evaluated in two health centres. Light microscopy in a reference laboratory was used as the gold standard. Results A total of 2,576 patients were included in the analysis. All of the RDTs tested had relatively high sensitivity for detecting any parasitaemia [Bioline SD (97%, First response malaria (92%, Paracheck (91%, ICT diagnostics (90%], but low specificity [Bioline SD (39%, First response malaria (42%, Paracheck (68%, ICT diagnostics (54%]. Specificity was significantly lower in patients who self-treated with an anti-malarial in the previous two weeks (odds ratio (OR 0.5; p-value 15 years old (OR 0.4, p-value Conclusions The results of this evaluation, combined with other published data and global recommendations, have been used to select RDTs for national scale-up. In addition, the study identified some key issues that need to be further delineated: the low field specificity of RDTs, variable RDT performance by different cadres of health workers and the need for a robust quality assurance system. Close monitoring of RDT scale-up will be needed to ensure that RDTs truly improve malaria case management.

  8. Utilisation du test GeneXpert pour le diagnostic de la tuberculose au ...

    African Journals Online (AJOL)

    Utilisation du test GeneXpert pour le diagnostic de la tuberculose au service des maladies infectieuses du CHNU de Fann. Sylvie Audrey Diop, Aminata Massaly, Daye Ka, Noel Magloire Manga, Louise Fortes-Déguénonvo, Cheikh Tidiane Ndour, Viviane Marie Pierre Cisse, Moussa Seydi ...

  9. Diagnostic testing for celiac disease among patients with abdominal symptoms a systematic review

    NARCIS (Netherlands)

    van der Windt, D.A.W.M.; Jellema, A.P.; Mulder, C.J.J.; Kneepkens, C.M.F.; van der Horst, H.E.

    2010-01-01

    Context: The symptoms and consequences of celiac disease usually resolve with a lifelong gluten-free diet. However, clinical presentation is variable and most patients presenting with abdominal symptoms in primary care will not have celiac disease and unnecessary diagnostic testing should be

  10. Diagnostic testing for celiac disease among patients with abdominal symptoms: a systematic review

    NARCIS (Netherlands)

    van der Windt, Daniëlle A. W. M.; Jellema, Petra; Mulder, Chris J.; Kneepkens, C. M. Frank; van der Horst, Henriëtte E.

    2010-01-01

    The symptoms and consequences of celiac disease usually resolve with a lifelong gluten-free diet. However, clinical presentation is variable and most patients presenting with abdominal symptoms in primary care will not have celiac disease and unnecessary diagnostic testing should be avoided. To

  11. Diagnostic Tests for The Control of Foot and Mouth Disease: An ...

    African Journals Online (AJOL)

    This paper describes the various diagnostic tests available for FMD, the limitations of each and their potential application in a low technology setting. The need to have complementary field and laboratory operations including suitable samples and transport methods are discussed, and examples are given. The importance of ...

  12. Mathematics Diagnostic Testing in Engineering: An International Comparison between Ireland and Portugal

    Science.gov (United States)

    Carr, M.; Fidalgo, C.; Bigotte de Almeida, M. E.; Branco, J. R.; Santos, V.; Murphy, E.; Ní Fhloinn, E.

    2015-01-01

    Concern has been expressed throughout Europe about the significant deficiencies in the basic mathematical skills of many engineering undergraduates. Mathematics diagnostic tests in the UK, Ireland and Portugal have shown these shortcomings, which provide a challenge to those striving to introduce more innovative educational practices into…

  13. A Global Comparative Evaluation of Commercial Immunochromatographic Rapid Diagnostic Tests for Visceral Leishmaniasis

    NARCIS (Netherlands)

    Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen; Khanal, Basudha; Das, Murari; Oliveira, Edward; de Assis, Tália Machado; Costa, Dorcas Lamounier; Bhaskar, Khondaker Rifathassan; Huda, M. Mamun; Hassan, Mukidul; Abdoun, Asim Osman; Awad, Aymen; Osman, Mohamed; Prajapati, Dinesh Kumar; Gidwani, Kamlesh; Tiwary, Puja; Paniago, Anamaria Mello Miranda; Sanchez, Maria Carmen Arroyo; Celeste, Beatriz Julieta; Jacquet, Diane; Magiri, Charles; Muia, A.; Kesusu, J.; Ageed, Al Farazdag; Galal, Nuha; Osman, Osman Salih; Gupta, A. K.; Bimal, Afrad S.; Das, V. N. R.

    2012-01-01

    Background. Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Methods. Commercial VL RDTs

  14. Diagnostic test for prenatal identification of Down's syndrome and mental retardation and gene therapy therefor

    Science.gov (United States)

    Smith, Desmond J.; Rubin, Edward M.

    2000-01-01

    A a diagnostic test useful for prenatal identification of Down syndrome and mental retardation. A method for gene therapy for correction and treatment of Down syndrome. DYRK gene involved in the ability to learn. A method for diagnosing Down's syndrome and mental retardation and an assay therefor. A pharmaceutical composition for treatment of Down's syndrome mental retardation.

  15. Diagnostic value of R wave amplitude changes during exercise testing after myocardial infarction

    NARCIS (Netherlands)

    de Hert, S.; Vrints, C.; Vanagt, E.; Snoeck, J.

    1986-01-01

    To determine the diagnostic value of R wave amplitude changes occurring during exercise testing after myocardial infarction, exercise ECG's and coronary angiograms were reviewed in 76 postinfarction patients and in 40 patients with normal coronary arteries. During exercise, an increase in R wave

  16. Comorbidity negatively influences the outcomes of diagnostic tests for musculoskeletal pain in the orofacial region

    NARCIS (Netherlands)

    Koutris, M.; Visscher, C.M.; Lobbezoo, F.; Naeije, M.

    2013-01-01

    The aim of this study was to investigate whether diagnostic tests for musculoskeletal pain in the orofacial region [temporomandibular disorder (TMD) pain] are influenced by the presence of comorbid conditions, and to determine whether this influence decreases when the presence of "familiar pain" is

  17. Early Improvement As a Predictor of Later Response to Antipsychotics in Schizophrenia: A Diagnostic Test Review

    NARCIS (Netherlands)

    Samara, Myrto T.; Leucht, Claudia; Leeflang, Mariska M.; Anghelescu, Ion-George; Chung, Young-Chul; Crespo-Facorro, Benedicto; Elkis, Helio; Hatta, Kotaro; Giegling, Ina; Kane, John M.; Kayo, Monica; Lambert, Martin; Lin, Ching-Hua; Möller, Hans-Jürgen; Pelayo-Terán, José María; Riedel, Michael; Rujescu, Dan; Schimmelmann, Benno G.; Serretti, Alessandro; Correll, Christoph U.; Leucht, Stefan

    2015-01-01

    How long clinicians should wait before considering an antipsychotic ineffective and changing treatment in schizophrenia is an unresolved clinical question. Guidelines differ substantially in this regard. The authors conducted a diagnostic test meta-analysis using mostly individual patient data to

  18. Comparison of agar gel immunodiffusion test, enzyme-linked immunosorbent assay and PCR in diagnostics of enzootic bovine leukosis

    Directory of Open Access Journals (Sweden)

    Malovrh Tadej

    2005-01-01

    Full Text Available Bovine leukaemia virus (BLV is a retrovirus that induces a chronic infection in cattle. Once infected, cattle remain virus carriers for life and start to show an antibody response within a few weeks after infection. Eradication and control of the disease are based on early diagnostics and segregation of the carriers. The choice of a diagnostic method depends on the eradication programme, money resources and characteristics of the herd to be analysed. The agar gel immunodiffusion (AGID test has been the serological test of choice for routine diagnosis of serum samples. Nevertheless, in more recent years, the enzyme-linked immunosorbent assay (ELISA has replaced the AGID for large scale testing. For this purpose, commercially available BLV-ELISA kits were compared to the AGID and to the polymerase chain reaction (PCR method performed with two sets of primers, amplifying env region. The ELISA kit based on the p24 core protein was found to be less specific and served as a screening test. The ELISA kit based on the envelope glycoprotein (gpSI served as a verification test and gave a good correlation with the AGID test and PCR method. However, ELISA showed a higher sensitivity than AGID. The p24 based ELiSA was useful for screening a large number of samples, whereas gp51 based ELISA, AGID and PCR were more important for detecting the antibody response against the individual BLV-proteins and therefore for verification of the infection with BLV.

  19. Quality of information accompanying on-line marketing of home diagnostic tests.

    Science.gov (United States)

    Datta, Adrija K; Selman, Tara J; Kwok, Tony; Tang, Teresa; Khan, Khalid S

    2008-01-01

    To assess the quality of information provided to consumers by websites marketing medical home diagnostic tests. A cross-sectional analysis of a database developed from searching targeted websites. Data sources were websites written in English which marketed medical home diagnostic tests. A meta-search engine was used to identify the first 20 citations for each type of home diagnostic medical test. Relevant websites limited to those written in English were reviewed independently and in triplicate, with disputes resolved by two further reviewers. Information on the quality of these sites was extracted using a pre-piloted performer. 168 websites were suitable for inclusion in the review. The quality of these sites showed marked variation. Only 24 of 168 (14.2%) complied with at least three-quarters of the quality items and just over half (95 of 168, 56.5%) reported official approval or certification of the test. Information on accuracy of the test marketed was reported by 87 of 168 (51.7%) websites, with 15 of 168 (8.9%) providing a scientific reference. Instructions for use of the product were found in 97 of 168 (57.9%). However, the course of action to be taken after obtaining the test result was stated in only 63 of 168 (37.5%) for a positive result and 43 of 168 (25.5%) for a negative result. The quality of information posted on commercial websites marketing home tests online is unsatisfactory and potentially misleading for consumers.

  20. Evaluation of sensitivity and specificity of bone marrow trephine biopsy tests in an Indian teaching hospital

    Directory of Open Access Journals (Sweden)

    Sima Chauhan

    2018-06-01

    Full Text Available Introduction: Bone marrow aspiration (BMA and bone marrow biopsy (BMB is an indispensable diagnostic tool for evaluating haematological and non-haematological disorders and patient follow-up in present era. We have compared the advantages of trephine biopsy over bone marrow aspiration in these patients. Aim and objective: To evaluate sensitivity and specificity of trephine biopsy test for haematological and non haematological disorder patients in comparison to bone marrow aspiration test. Materials and method: In this 1 year prospective study (June 2014–May 2015, we evaluated the haematological and non-haematological disorder patients by BMA and BMB (aided with I.H.C. when ever needed. The sensitivity and specificity of the tests were calculated. Results: Among, final 504 hemotological/non haematological disorder patients, 416 cases were diagnosed (+ve in BMA test, where as it was 494 in BMB test and with chi2 test it was highly significant as p = 0.0001. It was concluded that True positive cases were 416, True negative were 9 cases, false negative 78 cases and false positive was in one case only. The sensitivity and specificity of bone marrow trephine biopsy test was 84% and 90% respectively. Conclusion: BMB (aided with I.H.C is a gold standard test for detecting different haematological and non hamatological disorders. In our study the sensitivity and specificity of BMB test was 84% and 90% respectively. When performed in association with BMA in the same sitting, significantly augments the chances of reaching a correct diagnosis. Keywords: Bone marrow trephine biopsy, Bone marrow aspiration, Sensitivity, Specificity

  1. Formal Functional Test Designs: Bridging the Gap Between Test Requirements and Test Specifications

    Science.gov (United States)

    Hops, Jonathan

    1993-01-01

    This presentation describes the testing life cycle, the purpose of the test design phase, and test design methods and gives an example application. Also included is a description of Test Representation Language (TRL), a summary of the language, and an example of an application of TRL. A sample test requirement and sample test design are included.

  2. The Green Propellant Infusion Mission Thruster Performance Testing for Plume Diagnostics

    Science.gov (United States)

    Deans, Matthew C.; Reed, Brian D.; Arrington, Lynn A.; Williams, George J.; Kojima, Jun J.; Kinzbach, McKenzie I.; McLean, Christopher H.

    2014-01-01

    The Green Propellant Infusion Mission (GPIM) is sponsored by NASA's Space Technology Mission Directorate (STMD) Technology Demonstration Mission (TDM) office. The goal of GPIM is to advance the technology readiness level of a green propulsion system, specifically, one using the monopropellant, AF-M315E, by demonstrating ground handling, spacecraft processing, and on-orbit operations. One of the risks identified for GPIM is potential contamination of sensitive spacecraft surfaces from the effluents in the plumes of AF-M315E thrusters. NASA Glenn Research Center (GRC) is conducting activities to characterize the effects of AF-M315E plume impingement and deposition. GRC has established individual plume models of the 22-N and 1-N thrusters that will be used on the GPIM spacecraft. The model simulations will be correlated with plume measurement data from Laboratory and Engineering Model 22-N, AF-M315E thrusters. The thrusters are currently being tested in a small rocket, altitude facility at NASA GRC. A suite of diagnostics, including Raman spectroscopy, Rayleigh spectroscopy, and Schlieren imaging are being used to acquire plume measurements of AF-M315E thrusters. Plume data will include temperature, velocity, relative density, and species concentration. The plume measurement data will be compared to the corresponding simulations of the plume model. The GRC effort will establish a data set of AF-M315E plume measurements and a plume model that can be used for future AF-M315E applications.

  3. Diagnostic performance of a commercial immunoblot assay for myositis antibody testing.

    Science.gov (United States)

    Bundell, Chris; Rojana-Udomsart, Arada; Mastaglia, Frank; Hollingsworth, Peter; McLean-Tooke, Andrew

    2016-06-01

    The objective of this study was to establish a population based reference range for a commercial immunoblot assay detecting myositis specific autoantibodies (MSAs) and myositis associated autoantibodies (MAAs), and to assess the diagnostic performance of this reference range against the manufacturer's recommended ranges in a myositis patient cohort. A total of 124 patients from a myositis cohort and 197 healthy controls were serologically assessed using a commercial immunoblot containing eleven autoantigens (Jo-1, EJ, OJ, PL7, PL12, Mi-2, SRP, Ku, PMScl75, PMScl100 and Ro52) according to the manufacturer's instructions. Use of the manufacturer's reference ranges resulted in detection of MSAs in 19.4% of myositis patients and 9.1% of controls; MAAs were detected in 41.1% of myositis patients and 14.2% of controls. Reference values derived from the healthy control population resulted in significant differences in cut-off values for some autoantibodies, particularly Ro52 and PMScl75. Use of local reference ranges reduced detection of MSAs to 16.9% of myositis patients and 3% of healthy controls, with MAAs 23.4% of patients and 2% of healthy controls. Application of population based reference ranges resulted in significant differences in detection of MSAs and MAAs compared to the manufacturer's recommended ranges. Cut-off levels should be assessed to ensure suitability for the population tested. Copyright © 2016. Published by Elsevier B.V.

  4. Harmonization of malaria rapid diagnostic tests: best practices in labelling including instructions for use.

    Science.gov (United States)

    Jacobs, Jan; Barbé, Barbara; Gillet, Philippe; Aidoo, Michael; Serra-Casas, Elisa; Van Erps, Jan; Daviaud, Joelle; Incardona, Sandra; Cunningham, Jane; Visser, Theodoor

    2014-12-17

    Rapid diagnostic tests (RDTs) largely account for the scale-up of malaria diagnosis in endemic settings. However, diversity in labelling including the instructions for use (IFU) limits their interchangeability and user-friendliness. Uniform, easy to follow and consistent labelling, aligned with international standards and appropriate for the level of the end user's education and training, is crucial but a consolidated resource of information regarding best practices for IFU and labelling of RDT devices, packaging and accessories is not available. The Roll Back Malaria Partnership (RBM) commissioned the compilation of international standards and regulatory documents and published literature containing specifications and/or recommendations for RDT design, packaging and labelling of in vitro diagnostics (IVD) (which includes RDTs), complemented with a questionnaire based survey of RDT manufacturers and implementers. A summary of desirable RDT labelling characteristics was compiled, which was reviewed and discussed during a RBM Stakeholder consultation meeting and subsequently amended and refined by a dedicated task force consisting of country programme implementers, experts in RDT implementation, IVD regulatory experts and manufacturers. This process led to the development of consensus documents with a list of suggested terms and abbreviations as well as specifications for labelling of box, device packaging, cassettes, buffer bottle and accessories (lancets, alcohol swabs, transfer devices, desiccants). Emphasis was placed on durability (permanent printing or water-resistant labels), legibility (font size, letter type), comprehension (use of symbols) and ease of reference (e.g. place of labelling on the box or cassette packaging allowing quick oversight). A generic IFU template was developed, comprising background information, a template for procedure and reading/interpretation, a selection of appropriate references and a symbol key of internationally recognized

  5. Interlaboratory comparison and accreditation in quality control testing of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Kepler, K.; Vladimirov, A.; Servomaa, A.

    2005-01-01

    The Univ. of Tartu provides a quality control service to the majority of diagnostic X-ray departments in Estonia. Its methodology has been adopted from the IEC and other relevant standards. Recently the Testing Centre of the Univ. of Tartu was accredited on this methodology by ISO/IEC 17025. Besides the implementation of the quality management system, participation in interlaboratory comparison (ILC) was one of the prerequisites for the accreditation. Tests for estimating reproducibility of tube voltage and dose rate, accuracy of the voltage and accuracy of exposure time were carried out on a diagnostic X-ray unit in the Radiation and Nuclear Safety Authority in Helsinki. The measurement performance was judged by calculating deviation En normalised with respect to the stated uncertainties. En values for all tests were less than unity and by the common ILC criteria the testing performance could be considered as acceptable. (authors)

  6. The diagnostic effects of s-TSH and TRH stimulating test on subclinical thyroid function

    International Nuclear Information System (INIS)

    Lu Shujun; Wang Wenliang; Lu Shuyan; Zheng Linong; Hu Changjun; Fang Xiaozheng; Zheng Huian; Ma Meizhen

    2002-01-01

    The study was carried out to investigate the diagnostic effects of supersensitive TSH on diagnosing subclinical thyroid function with only once s-TSH detection and with TRH stimulating tests. TRH stimulating tests have been undertaken for 90 patients with different thyroid disease and 58 normal subjects. Diagnostic basal levels of s-TSH test in control group, subclinical hyperthyroidism group and subclinical hypothyroidism group were 2.20 +- 1.85 mIU/L, 0.54 +- 0.3 mIU/L and 9.08 +- 6.3 mIU/L, respectively, the levels of subclinical hyperthyroidism and subclinical hypothyroidism group were significantly higher than that of normal subjects group (P s -TSH>30 mIU/L. Dynamic observing of TRH stimulating tests have more effect than that of only once s-TSH detection in diagnosing subclinical thyroid function

  7. The introduction of compulsory compliance testing of medical diagnostic x-ray equipment in Western Australia

    International Nuclear Information System (INIS)

    Rafferty, M. W.; Jacob, C. S.

    1995-01-01

    Performance testing of medical diagnostic X-ray equipment can reveal equipment faults which, while not always clinically detectable, may contribute to reduced image quality and unnecessary radiation exposure of both patients and staff. Routine testing of such equipment is highly desirable to identify such faults and allows them to be rectified. The Radiological council of Western Australia is moving towards requiring compulsory compliance testing of all (new and existing) medical diagnostic X-ray equipment that all new mobile radiographic and new mammographic X-ray equipment be issued with a compliance test certificate as a prerequisite for registration. Workbooks which provide details of the tests required and recommended test methods have been prepared for medical radiographic (mobile and fixed), fluoroscopic and mammographic X-ray equipment. It is intended that future workbooks include details of the tests and methods for dental and computed tomography X-ray units. The workbooks are not limited to the compliance testing of items as specified in the Regulations, but include tests for other items such as film processing, darkrooms and image quality (for fluoroscopic equipment). Many of the workbook tests could be used within a regular quality assurance program for diagnostic X-ray equipment. Persons who conduct such compliance tests will need to be licensed and have all test certificates endorsed by a qualified expert. Suitable training and assessment of compliance testers will be required. Notification of such tests (including non-compliant items and corrective actions taken) will be required by the Radiological Council as a condition of equipment registration. 9 refs

  8. Systematic development of Phytophthora species-specific mitochondrial diagnostic markers for economically important members of the genus

    Science.gov (United States)

    The genus Phytophthora contains many invasive species to the USA that have the potential to cause significant damage to agriculture and native ecosystems. A genus and species-specific diagnostic assay was previously reported based on mitochondrial gene order differences that allowed for the systemat...

  9. Novel speed test for evaluation of badminton-specific movements.

    Science.gov (United States)

    Madsen, Christian M; Karlsen, Anders; Nybo, Lars

    2015-05-01

    In this study, we developed a novel badminton-specific speed test (BST). The test was designed to mimic match play. The test starts in the center of the court and consists of 5 maximal actions to sensors located in each of the 4 corners of the court. The 20 actions are performed in randomized order as dictated by computer screen shots displayed 1 second after completion of the previous action. We assessed day-to-day variation in elite players, and specificity of the test was evaluated by comparing 30-m sprint performance and time to complete the BST in 20 elite players, 21 skilled players, and 20 age-matched physical active subjects (non-badminton players). Sprint performance was similar across groups, whereas the elite players were significantly (p ≤ 0.05) faster in the BST (total test time: 32.3 ± 1.1 seconds; average: 1.6 seconds per action) than the skilled (34.1 ± 2.0 seconds) and non-badminton players (35.7 ± 1.7 seconds). Day-to-day coefficient of variation (CV) of the BST was 0.7% for the elite players, whereas CV for repeated tests on the same day was 1.7% for elite, 2.6% for skilled, and 2.5% for non-badminton players. On this basis, we suggest that the BST may be valuable for evaluation of short-term maximal movement speed in badminton players. Thus, the BST seems to be sport specific, as it may discriminate between groups (elite, less trained players, and non-badminton players) with similar sprinting performance, and the low test-retest variation may allow for using the BST to evaluate longitudinal changes, for example, training effects or seasonal variations.

  10. Diagnostic accuracy of repetition tasks for the identification of specific language impairment (SLI) in bilingual children: evidence from Russian and Hebrew.

    Science.gov (United States)

    Armon-Lotem, Sharon; Meir, Natalia

    2016-11-01

    Previous research demonstrates that repetition tasks are valuable tools for diagnosing specific language impairment (SLI) in monolingual children in English and a variety of other languages, with non-word repetition (NWR) and sentence repetition (SRep) yielding high levels of sensitivity and specificity. Yet, only a few studies have addressed the diagnostic accuracy of repetition tasks in bilingual children, and most available research focuses on English-Spanish sequential bilinguals. To evaluate the efficacy of three repetition tasks (forward digit span (FWD), NWR and SRep) in order to distinguish mono- and bilingual children with and without SLI in Russian and Hebrew. A total of 230 mono- and bilingual children aged 5;5-6;8 participated in the study: 144 bilingual Russian-Hebrew-speaking children (27 with SLI); and 52 monolingual Hebrew-speaking children (14 with SLI) and 34 monolingual Russian-speaking children (14 with SLI). Parallel repetition tasks were designed in both Russian and Hebrew. Bilingual children were tested in both languages. The findings confirmed that NWR and SRep are valuable tools in distinguishing monolingual children with and without SLI in Russian and Hebrew, while the results for FWD were mixed. Yet, testing of bilingual children with the same tools using monolingual cut-off points resulted in inadequate diagnostic accuracy. We demonstrate, however, that the use of bilingual cut-off points yielded acceptable levels of diagnostic accuracy. The combination of SRep tasks in L1/Russian and L2/Hebrew yielded the highest overall accuracy (i.e., 94%), but even SRep alone in L2/Hebrew showed excellent levels of sensitivity (i.e., 100%) and specificity (i.e., 89%), reaching 91% of total diagnostic accuracy. The results are very promising for identifying SLI in bilingual children and for showing that testing in the majority language with bilingual cut-off points can provide an accurate classification. © 2016 Royal College of Speech and Language

  11. CLASSIFICATION OF TEMPOROMANDIBULAR-JOINT OSTEOARTHROSIS AND INTERNAL DERANGEMENT .2. SPECIFIC DIAGNOSTIC-CRITERIA

    NARCIS (Netherlands)

    STEGENGA, B; DEBONT, LGM; BOERING, G

    Separate entities of temporomandibular joint osteoarthrosis and internal derangement are operationally defined. Criteria are based on an analysis of the diagnostic significance of symptoms and signs, principles of synovial joint pathology in general, and on therapeutic considerations. The primary

  12. Dry Eye Disease: Concordance Between the Diagnostic Tests in African Eyes.

    Science.gov (United States)

    Onwubiko, Stella N; Eze, Boniface I; Udeh, Nnenma N; Onwasigwe, Ernest N; Umeh, Rich E

    2016-11-01

    To assess the concordance between the diagnostic tests for dry eye disease (DED) in a Nigerian hospital population. The study was a hospital-based cross-sectional survey of adults (≥18 years) presenting at the eye clinic of the University of Nigeria Teaching Hospital (UNTH), Enugu; September-December, 2011. Participants' socio-demographic data were collected. Each subject was assessed for DED using the "Ocular Surface Disease Index" (OSDI) questionnaire, tear-film breakup time (TBUT), and Schirmer test. The intertest concordance was assessed using kappa statistic, correlation, and regression coefficients. The participants (n=402; men: 193) were aged 50.1±19.1 standard deviation years (range: 18-94 years). Dry eye disease was diagnosed in 203 by TBUT, 170 by Schirmer test, and 295 by OSDI; the concordance between the tests were OSDI versus TBUT (Kappa, κ=-0.194); OSDI versus Schirmer (κ=-0.276); and TBUT versus Schirmer (κ=0.082). Ocular Surface Disease Index was inversely correlated with Schirmer test (Spearman ρ=-0.231, P<0.001) and TBUT (ρ=-0.237, P<0.001). In the linear regression model, OSDI was poorly predicted by TBUT (β=-0.09; 95% confidence interval (CI): -0.26 to -0.03, P=0.14) and Schirmer test (β=-0.35, 95% CI: -0.53 to -0.18, P=0.18). At UNTH, there is poor agreement, and almost equal correlation, between the subjective and objective tests for DED. Therefore, the selection of diagnostic test for DED should be informed by cost-effectiveness and diagnostic resource availability, not diagnostic efficiency or utility.

  13. How to diagnose neuropathic pain? The contribution from clinical examination, pain questionnaires and diagnostic