WorldWideScience

Sample records for species concentration measurements

  1. Fluxes of chemically reactive species inferred from mean concentration measurements

    NARCIS (Netherlands)

    Galmarini, S.; Vilà-Guerau De Arellano, J.; Duyzer, J.H.

    1997-01-01

    A method is presented for the calculation of the fluxes of chemically reactive species on the basis of routine measurements of meteorological variables and chemical species. The method takes explicity into account the influence of chemical reactions on the fluxes of the species. As a demonstration

  2. Simultaneous measurement of the concentrations of soot particles and gas species in light hydrocarbon flames using mass spectrometry

    International Nuclear Information System (INIS)

    Li, Qingxun; Liu, Fang; Wang, Dezheng; Wang, Tiefeng

    2014-01-01

    Besides gas species concentrations, soot volume fractions are also important data in the study of flames. This work describes the simultaneous measurement of the concentrations of soot and gas species in light hydrocarbon flames by in situ sampling and mass spectrometry (MS).The reaction medium was frozen by sampling into a very low-pressure tube, and the soot selectivity (proportion of carbon atoms in the reactant converted to soot) was determined from the C and H mass balances using the measured concentrations of the gas species and the mass of soot present per unit gas volume. The H/C ratio of the soot was measured by a thermogravimetry–mass spectrometry combination. The soot volume fraction was calculated from the soot selectivity and density of the soot. The soot selectivity measured by this reduced pressure sampling mass spectrometry (RPSMS) method was verified by measurements using the gravimetric sampling technique where the mass of soot collected in a volume of gas was weighed by a high precision balance. For most of the measurements, the uncertainty in the soot volume fraction was ±5%, but this would be larger when the soot volume fractions are less than 1 ppm. For demonstration, the RPSMS method was used to study a methane fuel-rich flame where the soot volume fractions were 1–5 ppm. The simultaneous measurement of concentrations of soot and gas species is useful for the quantitative study of flames. (paper)

  3. Estimations of natural variability between satellite measurements of trace species concentrations

    Science.gov (United States)

    Sheese, P.; Walker, K. A.; Boone, C. D.; Degenstein, D. A.; Kolonjari, F.; Plummer, D. A.; von Clarmann, T.

    2017-12-01

    In order to validate satellite measurements of atmospheric states, it is necessary to understand the range of random and systematic errors inherent in the measurements. On occasions where the measurements do not agree within those errors, a common "go-to" explanation is that the unexplained difference can be chalked up to "natural variability". However, the expected natural variability is often left ambiguous and rarely quantified. This study will look to quantify the expected natural variability of both O3 and NO2 between two satellite instruments: ACE-FTS (Atmospheric Chemistry Experiment - Fourier Transform Spectrometer) and OSIRIS (Optical Spectrograph and Infrared Imaging System). By sampling the CMAM30 (30-year specified dynamics simulation of the Canadian Middle Atmosphere Model) climate chemistry model throughout the upper troposphere and stratosphere at times and geolocations of coincident ACE-FTS and OSIRIS measurements at varying coincidence criteria, height-dependent expected values of O3 and NO2 variability will be estimated and reported on. The results could also be used to better optimize the coincidence criteria used in satellite measurement validation studies.

  4. FK concentrator outdoor measurements

    OpenAIRE

    Hernández Sanz, Maikel; Vilaplana, J., J.; Benitez Gimenez, Pablo; Mohedano,, Rubén; Zamora Herranz, Pablo; Miñano Dominguez, Juan Carlos; Mendes Lopes, Joao

    2013-01-01

    The FK is a two-stage optical concentrator for CPV, composed by a Fresnel lens working as POE and a refractive element working as SOE. Both elements perform Köhler integration, for uniform irradiance purposes. The FK has demonstrated that compares very well with other Fresnel-based concentrator optics. Recent on-sun measurements carried out on an FK mono-module prototype have already shown outstanding results, achieving electrical efficiencies over 34%. Further optimization of optical design ...

  5. In situ, measurements on plutonium concentration, in vegetal and animal marine species as a function of their phylogenetic position

    International Nuclear Information System (INIS)

    Fraizier, Albert; Guary, J.-C.

    1975-10-01

    The accumulation of plutonium by 31 vegetal and animal marine species belonging to a large number of phyla was demonstrated in a reference coastal site. Fixation levels ranging from 171.6pCi/kg fresh weight for a lichen to 0.04pCi/k fresh weight for a fish showed that the retention of the radionuclide by the organisms studied was related to their phylogenetic position. Biological indicators especially suitable for monitoring coastal plutonium radioactivity has been identified [fr

  6. A model for oxidizing species concentrations in boiling water reactors

    International Nuclear Information System (INIS)

    Sun, B.; Chexal, B.; Pathania, R.; Chun, J.; Ballinger, R.; Abdollahian, D.

    1993-01-01

    To evaluate and control the intergranular stress corrosion cracking of boiling water reactor (BWR) vessel internal components requires knowledge of the concentration of oxidizing species that affects the electrochemical potentials in various regions of a BWR. In a BWR flow circuit, as water flows through the radiation field, the radiolysis process and chemical reactions lead to the production of species such as oxygen, hydrogen, and hydrogen peroxide. Since chemistry measurements are difficult inside BWRs, analytical tools have been developed by Ruiz and Lin, Ibe and Uchida and Chun and Ballinger for estimating the concentration of species that provide the necessary input for water chemistry control and material protection

  7. Use of Measured Species Class Concentrations with Chemical Kinetic Modeling for the Prediction of Autoxidation and Deposition of Jet Fuels (Postprint)

    National Research Council Canada - National Science Library

    Kuprowicz, Nicholas J; Zabarnick, Steven; West, Zachary J; Ervin, Jamie S

    2007-01-01

    .... In the present work, a chemical kinetic mechanism developed previously is refined to include the roles of key fuel species classes, such as phenols, reactive sulfur species, dissolved metals, and hydroperoxides...

  8. Seasonal variation in radiocesium concentrations in three tree species

    International Nuclear Information System (INIS)

    Garten, C.R. Jr.; Briese, L.A.; Sharitz, R.R.; Gentry, J.B.

    1975-01-01

    Radiocesium concentrations in leaves and stems of black willow (Salix nigra), wax myrtle (Myrica cerifera), and tag alder (Alnus serrulata) trees inhabiting a floodplain contaminated by production-reactor effluents were measured over 1 year. In willow and myrtle trees, leaf radiocesium levels were highest in the spring and declined during the growing season; stem levels remained relatively unchanged or exhibited a slight increase. Seasonal changes in alder tree parts depended on the site examined. The relationship among component parts was essentially consistent across species and collecting sites in the summer. The radiocesium concentrations in order of rank were: roots greater than or equal to leaves greater than stems. Species differences in component-part radiocesium levels were dependent on the part sampled and the collecting site examined. Mean soil to plant-part concentration factors in summer ranged from 0.9 to 7.6, and species means across leaves, stems, and roots averaged 2.1, 3.8, and 6.2 for alder, willow, and myrtle trees, respectively

  9. Total mercury concentration in common fish species of Lake Victoria ...

    African Journals Online (AJOL)

    Total mercury (THg) concentration was analysed in muscles of common fish species of Lake Victoria in the eastern and southern parts of the lake using cold vapour Atomic Absorption Spectrophotometric technique. Mercury concentration in all fish species was generally lower than the WHO maximum allowable ...

  10. Diverse microbial species survive high ammonia concentrations

    Science.gov (United States)

    Kelly, Laura C.; Cockell, Charles S.; Summers, Stephen

    2012-04-01

    Planetary protection regulations are in place to control the contamination of planets and moons with terrestrial micro-organisms in order to avoid jeopardizing future scientific investigations relating to the search for life. One environmental chemical factor of relevance in extraterrestrial environments, specifically in the moons of the outer solar system, is ammonia (NH3). Ammonia is known to be highly toxic to micro-organisms and may disrupt proton motive force, interfere with cellular redox reactions or cause an increase of cell pH. To test the survival potential of terrestrial micro-organisms exposed to such cold, ammonia-rich environments, and to judge whether current planetary protection regulations are sufficient, soil samples were exposed to concentrations of NH3 from 5 to 35% (v/v) at -80°C and room temperature for periods up to 11 months. Following exposure to 35% NH3, diverse spore-forming taxa survived, including representatives of the Firmicutes (Bacillus, Sporosarcina, Viridibacillus, Paenibacillus, Staphylococcus and Brevibacillus) and Actinobacteria (Streptomyces). Non-spore forming organisms also survived, including Proteobacteria (Pseudomonas) and Actinobacteria (Arthrobacter) that are known to have environmentally resistant resting states. Clostridium spp. were isolated from the exposed soil under anaerobic culture. High NH3 was shown to cause a reduction in viability of spores over time, but spore morphology was not visibly altered. In addition to its implications for planetary protection, these data show that a large number of bacteria, potentially including spore-forming pathogens, but also environmentally resistant non-spore-formers, can survive high ammonia concentrations.

  11. Concentration factors of 226 Ra in the mullet species Liza aurata

    International Nuclear Information System (INIS)

    Antovic, I.; Antovic, N.M.

    2011-01-01

    On the basis of measured 226 Ra activity concentrations in whole individuals of the mullet species Liza aurata, its muscles and skeleton, concentration factors for transfer of radium from water and sediment to this mullet species from the South Adriatic Sea, have been determined. (author) [sr

  12. Recalculation of measured fuel nuclide concentrations

    International Nuclear Information System (INIS)

    Moeller, W.

    1984-01-01

    The concentrations and concentration ratios of heavy fuel nuclides determined in the Central Institute for Nuclear Research Rossendorf on the basis of destructive burnup measurements are compared with the results of microburnup calculations. The possibility is discussed to improve the results by taking into account the spectral characteristics at the positions of the measuring samples. (author)

  13. Continuous measurements of outdoor radon concentrations

    International Nuclear Information System (INIS)

    Iida, T.; Ikebe, Y.; Suzuki, K.; Ueno, K.; Komura, K.; Kato, I.; Jin Yihe

    1993-01-01

    The authors studied and developed an electrostatic 222 Rn monitor and have measured continuously outdoor radon ( 222 Rn) concentrations at Nagoya University since 1985. Four 222 Rn monitors were newly constructed to measure outdoor 222 Rn concentrations at other locations. The 222 Rn concentrations at Nagoya and Kasugai show a clear diurnal variation in autumn, and a seasonal pattern of a spring-summer minimum and a autumn-winter maximum. The results at Toki are the same pattern as that at Nagoya except spring. The concentrations at Kanazawa show a slight seasonal variation. A clear diurnal variation is observed in summer. (4 figs.)

  14. Concentration and limit behaviors of stationary measures

    Science.gov (United States)

    Huang, Wen; Ji, Min; Liu, Zhenxin; Yi, Yingfei

    2018-04-01

    In this paper, we study limit behaviors of stationary measures of the Fokker-Planck equations associated with a system of ordinary differential equations perturbed by a class of multiplicative noise including additive white noise case. As the noises are vanishing, various results on the invariance and concentration of the limit measures are obtained. In particular, we show that if the noise perturbed systems admit a uniform Lyapunov function, then the stationary measures form a relatively sequentially compact set whose weak∗-limits are invariant measures of the unperturbed system concentrated on its global attractor. In the case that the global attractor contains a strong local attractor, we further show that there exists a family of admissible multiplicative noises with respect to which all limit measures are actually concentrated on the local attractor; and on the contrary, in the presence of a strong local repeller in the global attractor, there exists a family of admissible multiplicative noises with respect to which no limit measure can be concentrated on the local repeller. Moreover, we show that if there is a strongly repelling equilibrium in the global attractor, then limit measures with respect to typical families of multiplicative noises are always concentrated away from the equilibrium. As applications of these results, an example of stochastic Hopf bifurcation and an example with non-decomposable ω-limit sets are provided. Our study is closely related to the problem of noise stability of compact invariant sets and invariant measures of the unperturbed system.

  15. Measurements of natural 41Ca concentrations

    International Nuclear Information System (INIS)

    Steinhof, A.

    1989-05-01

    Atomic mass spectroscopic examinations on 41 Ca were carried out in the UNILAC accelerator. A sensitivity of about 10 -15 was achieved. This would allow the measurement of present natural 41 Ca concentrations as soon as the problem of the transmission determination is solved. In this respect suggestions were worked out and their feasibility discussed. The detection of 41 Ca-ions is especially free of background when high UNILAC-energies are applied. An estimation showed a background level corresponding with a 41 Ca concentration of less then 10 -17 referred to 40 Ca. Besides an independent concept for the electromagnetic concentration of 41 Ca with variable concentration factors was developed. After being concentrated up to 50 respectively 25 times the initial concentration in the GSI mass separator, the 41 Ca concentration of three recent deer bones found in the Odenwald was measured by atomic mass spectroscopy in the 14UD-Pelletron Tandem in Rehovot (Israel). The measured 41 Ca concentrations ranged between 10 -14 to 10 -13 with consideration of the concentration factor. A theoretical study of the 41 Ca production in the earth's surface based on cosmic radiation illustrates the influence of trace elements on the neutron flux and thus on the 41 Ca production. This influence might be a possible explanation for the observed amplitude of variation of the 41 Ca concentration in recent bones which are of decisive importance for the feasibility of 41 Ca-related dating. In this work a method is suggested that does not depend on the amplitude of variation mentioned above and which would allow the determination of the erosion rate of rocks by its 41 Ca concentrations. (orig./HP) [de

  16. Measurement of absolute concentrations of minor reactive species in flames by cavity ring down absorption spectroscopy (CRDS) method; Mesure de concentrations absolues d'especes reactives minoritaires dans les flammes par la technique d'absorption cavity ring down spectroscopy (CRDS)

    Energy Technology Data Exchange (ETDEWEB)

    Mercier, X.

    2000-11-15

    Combustion processes, which represent our main source of energy today, arouse still numerous questioning. It likes essentially the complexity of the involved chemical mechanisms as well as in the inherent difficulty to the study of an environment which is the field of several thousand simultaneous reactions. Now, even if powerful models exist, allowing the simulation of complex chemical systems, they can not predict any process of combustion and the experimental approach of these ones is still essential for the improvement of the existing models. In particular, the quantitative measure of minor species in flames constitutes a fundamental stage in the validation of the chemical mechanisms with high temperature. It is in this optics that we developed a new technique for flames study, the Cavity Ring-Down Spectroscopy (CRDS). This technique (appeared to the end of the 80's (O' Keefe and Deacon [1988]) within the framework of a spectroscopic study) is similar to a very high sensibility absorption method. The principle of the CRDS technique is based on the measure of the lifetime of an laser pulse injected in an optical cavity within which is an absorbing sample. in this report, we show the interest and the potentialities of the CRDS for the study of homogeneous flames. To do it, we clarify in detail the principle of the CRDS and the care to be taken for the measure of absolute concentrations. Besides, a comparison of the absolute concentrations profiles obtained by CRDS (of CN and CH notably) in a CH{sub 4} /O{sub 2} flame seeded with NO, with those stemming from the modelling by means of the software PREMIX is also presented. The very good agreement which reveals this comparison tends to show that the CRDS, because of its high sensibility and its direct quantitative character, is one of the most efficient methods for the measure of minor species absolute concentrations in homogeneous flames. (author)

  17. Measurement of tritium concentration in urine

    International Nuclear Information System (INIS)

    Sekiyama, Shigenobu; Deshimaru, Takehide

    1979-01-01

    Concerning the safety management of the advanced thermal reactor ''Fugen'', the internal exposure management for tritium is important, because heavy water is used as the moderator in the reactor, and tritium is produced in the heavy water. Tritium is the radioactive nuclide with the maximum β-ray energy of 18 keV, and the radiation exposure is limited to the internal exposure in human bodies, as tritium is taken in through the skin and by breathing. The tritium concentration in urine of the operators of the Fugen plant was measured. As for tritium measurement, the analysis of raw urine, the analysis after passing through mixed ion exchange resin and the analysis after distillation are applied. The scintillator, the liquid scintillation counter, the ion exchange resin and the distillator are introduced. The preliminary survey was conducted on the urine sample, the scintillator the calibration, etc. The measuring condition, the measurement of efficiency, and the limitation of detection with various background are explained, with the many experimental data and the calculating formula. Concerning the measured tritium concentration in urine, the tritium concentrations in distilled urine, raw urine and the urine refined with ion exchange resin were compared, and the correlation formulae are presented. The actual tritium concentration value in urine was less than 50 pci/ml. The measuring methods of raw urine and the urine refined with ion exchange resin are adequate as they are quick and accurate. (Nakai, Y.)

  18. The active titration method for measuring local hydroxyl radical concentration

    Science.gov (United States)

    Sprengnether, Michele; Prinn, Ronald G.

    1994-01-01

    We are developing a method for measuring ambient OH by monitoring its rate of reaction with a chemical species. Our technique involves the local, instantaneous release of a mixture of saturated cyclic hydrocarbons (titrants) and perfluorocarbons (dispersants). These species must not normally be present in ambient air above the part per trillion concentration. We then track the mixture downwind using a real-time portable ECD tracer instrument. We collect air samples in canisters every few minutes for roughly one hour. We then return to the laboratory and analyze our air samples to determine the ratios of the titrant to dispersant concentrations. The trends in these ratios give us the ambient OH concentration from the relation: dlnR/dt = -k(OH). A successful measurement of OH requires that the trends in these ratios be measureable. We must not perturb ambient OH concentrations. The titrant to dispersant ratio must be spatially invariant. Finally, heterogeneous reactions of our titrant and dispersant species must be negligible relative to the titrant reaction with OH. We have conducted laboratory studies of our ability to measure the titrant to dispersant ratios as a function of concentration down to the few part per trillion concentration. We have subsequently used these results in a gaussian puff model to estimate our expected uncertainty in a field measurement of OH. Our results indicate that under a range of atmospheric conditions we expect to be able to measure OH with a sensitivity of 3x10(exp 5) cm(exp -3). In our most optimistic scenarios, we obtain a sensitivity of 1x10(exp 5) cm(exp -3). These sensitivity values reflect our anticipated ability to measure the ratio trends. However, because we are also using a rate constant to obtain our (OH) from this ratio trend, our accuracy cannot be better than that of the rate constant, which we expect to be about 20 percent.

  19. Measurement of concentration of heavy water

    International Nuclear Information System (INIS)

    Tsukamoto, Yuichi; Kondo, Mitsuo; Sakurai, Naoyuki

    1979-01-01

    The concentration of heavy water is measured as one of the technical management in the Fugen plant. The heavy water is used as the moderator in the reactor. The measuring method depends on the theory of light absorption. The light absorption range of heavy water spreads from near infrared to infrared zone. The near infrared absorption was adopted for the purpose, as the absorption is much larger in infrared zone, and the measurement has to be conducted, limiting the apparent absorption. This measuring method is available to determine the concentration of heavy water in the broad range exactly. The preparation of heavy water sample and the measurement of the absorption spectra of near infrared ray are explained, as the experimental procedure. The sample cell was made of quartz, and the spectroscope was the Hitachi 323 type. The resolving power is 100 nm and 27 nm for the wave length of 1000 nm and 2500 nm, respectively. Concerning the measured results, the absorption was recorded in the wave length range from 600 nm to 2600 nm, and for the heavy water concentration range from 0 to 99.77 wt. %. The peaks of absorption were located at the wave length of 1450, 1660, 1920, 1970, 2020 and 2600 nm. The three kinds of fundamental vibration mode of the molecules of both light and heavy water are shown, and the peaks belong to H 2 O, HDO and D 2 O, respectively. The relation between the absorption and the heavy water concentration, and that between the transmissivity and the wave length are shown, when the cell thickness was varied to 5 mm and 20 mm, and the heavy water concentration to 21%, 62% and 99.85%. (Nakai, Y.)

  20. Portable method of measuring gaseous acetone concentrations.

    Science.gov (United States)

    Worrall, Adam D; Bernstein, Jonathan A; Angelopoulos, Anastasios P

    2013-08-15

    Measurement of acetone in human breath samples has been previously shown to provide significant non-invasive diagnostic insight into the control of a patient's diabetic condition. In patients with diabetes mellitus, the body produces excess amounts of ketones such as acetone, which are then exhaled during respiration. Using various breath analysis methods has allowed for the accurate determination of acetone concentrations in exhaled breath. However, many of these methods require instrumentation and pre-concentration steps not suitable for point-of-care use. We have found that by immobilizing resorcinol reagent into a perfluorosulfonic acid polymer membrane, a controlled organic synthesis reaction occurs with acetone in a dry carrier gas. The immobilized, highly selective product of this reaction (a flavan) is found to produce a visible spectrum color change which could measure acetone concentrations to less than ppm. We here demonstrate how this approach can be used to produce a portable optical sensing device for real-time, non-invasive acetone analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Concentration of mercury and selenium in tissues of five cetacean species from Croatian coastal waters

    Directory of Open Access Journals (Sweden)

    Bilandžić Nina

    2015-01-01

    Full Text Available Mercury (Hg and selenium (Se concentrations were measured in muscle, liver, kidney, spleen and lung tissues of five cetacean species, three dolphin (Stenella coeruleoalba, Tursiops truncatus and Grampus griseus and two whale species (Balaenoptera physalus and Ziphius cavirostris, stranded along the Croatian coast during the period 1999-2002. Statistically significant differences in Hg concentrations in muscle, spleen and lung, and Se in liver and lung of the different dolphin species were observed. Mercury levels in liver and spleen and Se levels in liver differed between young and adult T. truncatus species. A significant positive correlation between different tissue types for Hg and Se concentrations was observed. In all tissues tested, the lowest Hg and Se concentrations were found in B. physalus. Mercury concentrations were positively correlated with Se in all tissues. The results present one of few studies related to lung and spleen tissues in these mammals, particularly in the Adriatic Sea. Since very little data are available, this research provides new data on concentrations of Hg and Se in five cetacean species from the Adriatic Sea basin.

  2. Apparatus for measuring a concentration of radioactivity

    International Nuclear Information System (INIS)

    Tabuchi, H.; Ogushi, A.

    1978-01-01

    Disclosed is an apparatus for measuring concentration of radioactivity in a fluid circulating in a cooling system or a disposal system, etc., of a nuclear power plant (e.g. coolant), the apparatus having a plurality of sampling tubes with different diameters depending on the intensities of radioactivity, and the sampling tubes having valves for switching from one fluid to another fluid. The sampling tubes are connected to the system to a discharge pipe, and are disposed in the proximity of a radiation detector adapted to issue a signal representative of radiation. The issued signal is supplied to a multichannel pulse height analyzer and a data processing system providing an indication of the concentrations of radioactivities for respective radionuclides

  3. Measurements of the concentration of major chemical species in the flame of a test burner with a air swirling system; Mesures de concentration d`especes chimiques majoritaires dans la flamme d`un bruleur modele avec mise en rotation de l`air

    Energy Technology Data Exchange (ETDEWEB)

    Albert, St. [Gaz de France (GDF), 93 - La Plaine-Saint-Denis (France); Most, J.M.; Poireault, B. [Centre National de la Recherche Scientifique (CNRS), 86 - Poitiers (France)

    1996-12-31

    The study of combustion in industrial burners remains difficult because of the complexity of the equipments used: materials geometry, tri-dimensional flows etc.. The phenomena that control the combustion in a gas burner with a swirl air system has been studied thanks to a collaboration between the Direction of Research of Gaz de France (GdF) and the Laboratory for Combustion and Detonation Research (LCD) of the French National Centre of Scientific Research (CNRS). The burner used is developed by the LCD and the measurements of stable chemical species were performed by the CERSTA centre of GdF. These series of tests, performed in confined environment, have permitted to identify some of the parameters that influence combustion chemistry. Mapping of chemical species allows to distinguish 5 zones of flame development and also the zones of nitrogen oxides formation. Methane is rapidly centrifuged a few millimeters above the injection pipe and centrifuged with rotating combustion air. Carbon monoxide occurs immediately in the central recirculation zone which is weakly reactive (no oxygen and no methane). Oxygen content increases downflow from this area and carbon dioxide reaches its concentration maxima. CO formation decreases when the swirl number increases and CO{sub 2} formation occurs earlier. On the contrary, the emissions of CO and CH{sub 4} do not depend on the swirl value and the NO{sub x} values are only slightly dependent on this value. (J.S.)

  4. Measurements of radon concentrations in dwelling houses

    International Nuclear Information System (INIS)

    Birkholz, W.; Klink, T.

    1993-01-01

    Radon and its daughter products gain in importance in health protection and radiation safety. Especially in the southern region of Saxony radon concentrations in dwellings may be high by former silver and uranium mines. We found radon contents of about 20.000 Bq/m 3 in dwellings. To redevelop such houses it is necessary to know intrude path of radon. In present work we studied different measuring systems, active and passive detectors, short and long term integrating devices. By means of investigation of radon sources several redeveloping methods are rates as well from radiological as from civil engineering point of view. (author)

  5. Measurement of radon activity concentration in buildings

    International Nuclear Information System (INIS)

    Godet, J.L.; Perrin, M.L.; Pineau, C.; Dechaux, E.

    2010-01-01

    Radon exposure, along with medical-related exposure, is the leading source of exposure to ionising radiation for the French population. Measurement campaigns are done in the action plan, drawn up by the French nuclear safety authority (ASN), in cooperation with the French directorate for housing, town planning and countryside (DHUP), the French radiation protection and nuclear safety institute (IRSN), the French health monitoring institute (InVS) and the French scientific and technical centre for construction (CSTB). The review of 2005-2008 measurement campaign shows that of the 7356 buildings screened, 84.8% had activity concentration levels below the 400 Bq/m 3 action level. For the other buildings (15.2%), action will be required to reduce human exposure to radon, possibly including building renovation/redevelopment work. In the 1999-2002 measurement campaign,12% of the 13,000 buildings screened had a radon activity concentration level higher than 400 Bq/m 3 . In addition, the ASN and the French general directorate of labour (DGT) are continuing to work on drawing up regulations for occupational risk management. The second national health and environment plan (PNSE 2) was published on 26 June 2009. It follows on from the actions initiated in PNSE 1, a document provided for under the Public Health Act dated 9 August 2004 and under the French 'Grenelle' environmental agreements. On the basis of guidelines laid out in PNSE 2, a radon action plan for 2009-2012 will be drawn up, enabling some of the actions to be continued, particularly in the fields of new building projects and dwellings. (author)

  6. Heavy Metal Concentrations in an Important Mangrove Species, Sonneratia caseolaris, in Peninsular Malaysia

    Directory of Open Access Journals (Sweden)

    Mohd Fazlin Nazli

    2010-01-01

    Full Text Available Mangrove forests in Peninsular Malaysia are increasingly threatened by heavy metal pollution. Due to their unique location, mangroves receive heavy metal pollution from upstream areas and the sea. However, little is known about the capacity of mangrove plants to take up and store heavy metals. In this study, the concentrations of cadmium (Cd, chromium (Cr, copper (Cu, lead (Pb and zinc (Zn in an important mangrove species, Sonneratia caseolaris, were measured. It was found that the total concentrations of Cd, Cr, Cu, Pb, and Zn in the sediments were below the general critical soil concentrations. However, the total concentrations of Cu and Pb in both the roots and leaves of Sonneratia caseolaris exceeded the general normal upper range in plants. This study has therefore shown the potential of Sonneratia caseolaris as a phytoremediation species for selected heavy metals in Malaysian mangrove ecosystem.

  7. Device for measuring the tritium concentration in a measuring gas

    International Nuclear Information System (INIS)

    Koran, P.

    1987-01-01

    The measuring gas is brought into contact via a measuring gas path with a diaphragm permeable to water, which separates the measuring gas path from a counter gas path leading to a proportional detector. The measuring gas path and the counter gas path are in counterflow in the area of diaphragm. The preferably hose diaphragm consists of a well-known ion exchange material, which can be used for gas drying purposes, which is permeable to water and tritium compounds similar to water, but is impermeable to other gases and liquids contained in air, particularly rare gases. In this way, the tritium concentration can be measured with great rare gas suppression. (orig./HP) [de

  8. Measurement of PCB concentrations in waters using a biomonitoring programme

    International Nuclear Information System (INIS)

    Mast, P.G.

    1993-01-01

    The book describes a PCB biomonitoring programme which was developed for measuring instantaneous PCB concentrations and permits the compilation of PCB action cadastres for different types of waters and subsequent derivation of current trends. Six representative congeners were selected as a basis for the quantitative routine analysis. The fish species bream (abramis brama) and roach (rutilus rutilus) were used as indicators in the PCB biomonitoring programme on account of their distribution and ecological demands. The age and growth rate of each fish destined for analysis was determined so as to ensure that only healthy fish would be used. In both fish species the dorsal musulature with its low scatter of test results and consistent PCB pattern (internal quantification) proved a representative body region. (orig.) [de

  9. Uranium concentrations in fossils measured by SIMS

    International Nuclear Information System (INIS)

    Uyeda, Chiaki; Okano, Jun

    1988-01-01

    Semiquantitative analyses of uranium in fossil bones and teeth were carried out by SIMS. The results show a tendency that uranium concentrations in the fossils increase with the ages of the fossils. It is noticed that fossil bones and teeth having uranium concentration of more than several hundred ppm are not rare. (author)

  10. Measures of School Integration: Comparing Coleman's Index to Measures of Species Diversity.

    Science.gov (United States)

    Mercil, Steven Bray; Williams, John Delane

    This study used species diversity indices developed in ecology as a measure of socioethnic diversity, and compared them to Coleman's Index of Segregation. The twelve indices were Simpson's Concentration Index ("ell"), Simpson's Index of Diversity, Hurlbert's Probability of Interspecific Encounter (PIE), Simpson's Probability of…

  11. Measuring Concentration in Data with an Exogenous Order

    OpenAIRE

    Abedieh, Jasmin; Groll, Andreas; Eugster, Manuel J. A.

    2013-01-01

    Concentration measures order the statistical units under observation according to their market share. However, there are situations where an order according to an exogenous variable is more appropriate or even required. The present article introduces a generalized definition of market concentration and defines a corresponding concentration measure. It is shown that this generalized concept of market concentration satisfies the common axioms of (classical) concentration measures. In an appl...

  12. Turbidimetry for measurement of radon concentration

    International Nuclear Information System (INIS)

    Wang Huanqiang

    1993-01-01

    This paper describes a turbidimetric technique counting the tracks registered on CR-39 foils exposed to radon. Instead of eyeview through microscope, by using the differential spectrophotometer, strong correlation between the radon cumulative concentration and track turbidence was observed(r=0.999). Under the etching condition of 7.07 mol·L -1 KOH water solution at 80 o C for 16 hr, linear regression showed that the ratio of track turbidence and cumulative concentration of radon exposure was 1.99 x 10 -1 turbidence (KBq m -1 h) -1 and the determination limit was 36 KBq m -3 h. The details of the experiments are represented in this paper. (Author)

  13. Radon concentration measurements in therapeutic spring water

    International Nuclear Information System (INIS)

    Deak, N.; Horvath, A.; Sajo B, L.; Marx, G.

    1996-01-01

    It is believed that people undergoing a curative cycle in a given spa, may receive a dose in the range of 400 mSv/year which is many times the average annual dose so that their risk of lung cancer may increase by 3% or more. To determine the risk due to the natural radioactivity, of the most frequented spas in Budapest (H), we selected four and some others located on the country side being of particular interest. Results of the radon concentration in spring water are presented, with the evidence that some spas have a high radon concentration. We conclude that patients receiving treatment may be exposed to an additional dose in the range of 29-76 mSv/year that at the bronchia could be between 445-1182 mSv/year. (authors). 6 refs., 2 figs., 2 tabs

  14. Leaching of Conductive Species: Implications to Measurements of Electrical Resistivity.

    Science.gov (United States)

    Spragg, R; Jones, S; Bu, Y; Lu, Y; Bentz, D; Snyder, K; Weiss, J

    2017-05-01

    Electrical tests have been used to characterize the microstructure of porous materials, the measured electrical response being determined by the contribution of the microstructure (porosity and tortuosity) and the electrical properties of the solution (conductivity of the pore solution) inside the pores of the material. This study has shown how differences in concentration between the pore solution (i.e., the solution in the pores) and the storage solution surrounding the test specimen leads to significant transport (leaching) of the conductive ionic species between the pore solution and the storage solution. Leaching influences the resistivity of the pore solution, thereby influencing electrical measurements on the bulk material from either a surface or uniaxial bulk resistance test. This paper has three main conclusions: 1.) Leaching of conductive species does occur with concentration gradients and that a diffusion based approach can be used to estimate the time scale associated with this change. 2.) Leaching of ions in the pore solution can influence resistivity measurements, and the ratio of surface to uniaxial resistivity can be used as a method to assess the presence of leaching and 3.) An estimation of the magnitude of leaching for standardized tests of cementitious materials.

  15. Quantification of the total Na,K-ATPase concentration in atria and ventricles from mammalian species by measuring 3H-ouabain binding to intact myocardial samples. Stability to short term ischemia reperfusion

    DEFF Research Database (Denmark)

    Schmidt, Thomas A; Svendsen, J H; Haunsø, S

    1990-01-01

    ,K-ATPase may be less than 1% due to loss during purification. A higher Na,K-ATPase concentration is found in small animals than in large animals. A relationship between higher concentration of Na,K-ATPase and larger pressure work in ventricles compared to atria is suggested. Myocardial 3H-ouabain binding sites...... were found to be stable for 20 min of ischemia, followed by 1 h of reperfusion, supporting the concept that myocyte injury induced by short term ischemia may be reversible and that reperfusion may result in normalization....

  16. Quantification of the total Na,K-ATPase concentration in atria and ventricles from mammalian species by measuring 3H-ouabain binding to intact myocardial samples. Stability to short term ischemia reperfusion

    DEFF Research Database (Denmark)

    Schmidt, T A; Svendsen, Jesper Hastrup; Haunsø, S

    2011-01-01

    ,K-ATPase may be less than 1% due to loss during purification. A higher Na,K-ATPase concentration is found in small animals than in large animals. A relationship between higher concentration of Na,K-ATPase and larger pressure work in ventricles compared to atria is suggested. Myocardial 3H-ouabain binding sites...... were found to be stable for 20 min of ischemia, followed by 1 h of reperfusion, supporting the concept that myocyte injury induced by short term ischemia may be reversible and that reperfusion may result in normalization....

  17. Mercury and lead concentrations in six cartilaginous fish species ...

    African Journals Online (AJOL)

    Mercury and lead concentrations in cartilaginous fishes from Lagos Lagoon and coastal waters of South-West Nigeria were investigated between May and August 2013. There are obvious discharges of toxic heavy metal substances into these waters and which can get to man by bioaccumulation and biomagnifications in ...

  18. Protectiveness of Species Sensitivity Distribution Hazard Concentrations for Acute Toxicity Used in Endangered Species Risk Assessment

    Science.gov (United States)

    A primary objective of threatened and endangered species conservation is to ensure that chemical contaminants and other stressors do not adversely affect listed species. Assessments of the ecological risks of chemical exposures to listed species often rely on the use of surrogate...

  19. Screening Study of Leaf Terpene Concentration of 75 Borneo Rainforest Plant Species: Relationships with Leaf Elemental Concentrations and Morphology

    Directory of Open Access Journals (Sweden)

    Jordi Sardans

    2015-01-01

    Full Text Available Terpenes confer advantage in plant protection against abiotic stresses such as heat and drought and biotic stresses such as herbivore and pathogen attack. We conducted a screening of leaf mono- and sesquiterpene concentrations in 75 common woody plant species in the rainforest of Danum Valley (Borneo. Terpene compounds were found in 73 out of the 75 analysed species. Similar or lower proportions have been reported in other parts of the world. To our knowledge, this study reports for the first time the foliar concentration of mono- and/or sesquiterpene for 71 species and 39 genera not previously analyzed. Altogether 80 terpene compounds were determined across the species, and out of these only linalool oxide and (E- g -bisabolene had phylogenetic signal. A significant negative relationship between leaf monoterpene concentration and leaf length was observed, but leaf mono- and sesquitepene concentration were not related to any other leaf morphological trait nor to leaf elemental composition. Functions such as temperature protection, radiation protection or signaling and communication could underlie the high frequency of terpene-containing species of this tropical ecosystem which has multiple and very diverse interactions among multiple species.

  20. Advances in deuterium dioxide concentration measurement

    Energy Technology Data Exchange (ETDEWEB)

    Shon, Woojung [University of Science & Technology, Daejeon (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yim, Sung Paal, E-mail: nspyim@kaeri.re.kr [University of Science & Technology, Daejeon (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Lim; Park, Hyunmin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Kwang Rag; Chung, Hongsuk [University of Science & Technology, Daejeon (Korea, Republic of); Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Cheo Kyung [Handong Global University, Pohang (Korea, Republic of)

    2016-11-01

    Highlights: • Heavy water (D{sub 2}O) with a high purity level is necessary for nuclear fusion application. • D{sub 2}O purity is analyzed using Fourier Transform infrared (FT-IR) spectroscopy and newly introduced off-axis integrated cavity output spectroscopy (OA-ICOS). • OA-ICOS has advantages in terms of analysis of D{sub 2}O vapor. • OA-ICOS is expected that it can be used for accurate isotopic analyses in the future. - Abstract: The deuterium–tritium (D–T) reaction has been identified as the most efficient reaction for fusion devices. Deuterium can be obtained by heavy water electrolysis. Heavy water (D{sub 2}O) with a high purity level is necessary for nuclear fusion application. A D{sub 2}O isotopic analysis is thus very important. A system for a heavy water analysis was built and a newly designed isotopic analysis experiment was carried out. We tried to analyze the D{sub 2}O purity using Fourier Transform infrared (FT-IR) spectroscopy and newly introduced off-axis integrated cavity output spectroscopy (OA-ICOS). We found that the OA-ICOS based on measurement via laser absorption spectroscopy shows very high sensitivity. We ameliorated the sensitivity by an order of magnitude of more than 10{sup 3}–10{sup 5}. We could make the apparatus smaller by employing very tiny diode laser and fiber optics elements of a DFB (Distributed Feedback) type. Consequently, our device has advantages in terms of maintainability and mobility even in a radioactive environment. This new method could be used for an accurate isotopic analysis in the future.

  1. Photosynthetic responses to understory shade and elevated carbon dioxide concentration in 4 northern hardwood tree species

    International Nuclear Information System (INIS)

    Sefcik, L.T.; Zak, D.R.; Ellsworth, D.S.

    2006-01-01

    Stimulation of photosynthesis in response to elevated carbon dioxide (CO 2 ) varies among tree species and species groups. In this study, seedling responses to elevated atmospheric carbon dioxide (CO 2 ) concentrations and solar irradiance over 2 growing seasons were investigated for shade tolerant Acer saccharum Marsh.; Fagus grandifolia J.F. Ehrh; and shade-intolerant Prunus serotina. Seedlings were exposed to a combination of elevated and ambient concentrations of CO 2 and understory shade in open-top chambers placed in a forest understory. It was observed that the elevated CO 2 treatment increased mean light-saturated net photosynthetic rates by 63 per cent in the shade-tolerant species and 67 per cent in the shade-intolerant species. When measured at the elevated CO 2 , long-term enhancement of photosynthesis was 10 per cent lower than the instantaneous enhancement observed in ambient-CO 2 -grown plants. As the growth irradiance increased, proportional enhancement due to elevated CO 2 decreased from 97 per cent for plants grown in deep shade to 47 per cent for plants grown in moderate shade. Results indicated that in nitrogen (N) limited northern temperate forests, trees grown in deep shade may display greater photosynthetic gains from a CO 2 enriched atmosphere than trees growing in more moderate shade, due to greater down-regulation. It was concluded that if elevated CO 2 levels promote the survival of shade-intolerant species in dim understory light, the future composition and dynamics of successional forest communities may be altered. 70 refs., 2 tabs., 3 figs

  2. Petroleum hydrocarbon concentrations in eight mollusc species along Tamilnadu coast, Bay of Bengal, India.

    Science.gov (United States)

    Veerasingam, S; Venkatachalapathy, R; Sudhakar, S; Raja, P; Rajeswari, V

    2011-01-01

    Eight mollusc species and sediment samples collected from three different stations along Tamilnadu coast, Bay of Bengal, India were analysed for the levels of petroleum hydrocarbons to elucidate the status of the petroleum residues in mollusc meant for human consumption. The concentrations of petroleum hydrocarbons in sediments along Tamilnadu coast varied from 5.04-25.5 microg/g dw (dry weight). High concentration of petroleum hydrocarbons in the sediment of Uppanar estuary (25.5 +/- 1.45 microg/g dw) was perhaps land and marine based anthropogenic sources of this region. The petroleum hydrocarbon residues in eight mollusc species collected from Uppanar, Vellar and Coleroon estuaries varied between 2.44-6.04 microg/g ww (wet weight). Although the concentration of petroleum hydrocarbons in sediment of the Uppanar region was markedly higher than the background, the petroleum hydrocarbon residues in mollusc collected from Uppanar estuary did not suggest bioaccumulation. The results signified that industrial growth has affected the aquatic environments and regular monitoring will help to adopt stringent pollution control measures for better management of the aquatic region.

  3. Metal concentrations in demersal fish species from Santa Maria Bay, Baja California Sur, Mexico (Pacific coast).

    Science.gov (United States)

    Jonathan, M P; Aurioles-Gamboa, David; Villegas, Lorena Elizabeth Campos; Bohórquez-Herrera, Jimena; Hernández-Camacho, Claudia J; Sujitha, S B

    2015-10-15

    Concentrations of 11 trace metals (Fe, Mn, Cr, Cu, Ni, Co, Pb, Zn, Cd, As, Hg) in 40 fish species from Santa Maria Bay, Baja California Sur, Mexico, the strategically important area for marine mammals and organisms were analyzed. Based on their concentrations the ranking of metals Fe>Zn>Ni>Cr>Mn>Pb>Cu>Co>As>Cd>Hg suggests that organism size, metabolism and feeding habits are correlated with metal concentrations. Local geological formations affect the concentrations of different metals in the aquatic environment and are subsequently transferred to fishes. The correlation analysis suggests that metabolism and nurturing habits impact the concentration of metals. Concentrations of Fe and Mn appear to be influenced by scavenging and absorption processes, which vary by species. The considerable variability in the metal concentrations obtained in different species underscores the importance of regular monitoring. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Nondestructive measurement for radionuclide concentration distribution in soil column

    International Nuclear Information System (INIS)

    Ogawa, Hiromichi; Ohnuki, Toshihiko; Yamamoto, Tadatoshi; Wadachi, Yoshiki

    1985-01-01

    A nondestructive method has been studied for determining the concentration of radionuclide (Cs-137) distributed in a soil column. The concentration distribution was calculated from the counting rate distribution using the efficiency matrix of a detector. The concentration distribution obtained by this method, with measuring efficiencies of theoretical calculation, coincides well with that obtained by the destructive sampling method. This method is, therefore, found to be effective for the measurement of one dimensional concentration distribution. The measuring limit of this method is affected not only by the radionuclide concentration but also by the shape of concentration distribution in a soil column and also by the way it is divided into concentration blocks. It is found that, the radioactive concentration up to 2.6 x 10 -4 μCi/g (9.62 Bq/g), and also the distribution up to where the concentration reduces to half at every 1 cm of depth, can be measured by this system. The concentration blocks can be divided into 1 cm of thickness as a minimum value. (author)

  5. Intermediate species measurement during iso-butanol auto-ignition

    KAUST Repository

    Ji, Weiqi

    2015-10-01

    © 2015 The Combustion Institute.Published by Elsevier Inc. All rights reserved. This work presents the time histories of intermediate species during the auto-ignition of iso-butanol at high pressure and intermediate temperature conditions obtained using a rapid compression machine and recently developed fast sampling system. Iso-butanol ignition delays were acquired for iso-butanol/O2 mixture with an inert/O2 ratio of 7.26, equivalence ratio of 0.4, in the temperature range of 840-950 K and at pressure of 25 bar. Fast sampling and gas chromatography were used to acquire and quantify the intermediate species during the ignition delay of the same mixture at P = 25.3 bar and T = 905 K. The ignition delay times and quantitative measurements of the mole fraction time histories of methane, ethene, propene, iso-butene, iso-butyraldehyde, iso-butanol, and carbon monoxide were compared with predictions from the detailed mechanisms developed by Sarathy et al., Merchant et al., and Cai et al. It is shown that while the Sarathy mechanism well predicts the overall ignition delay time, it overpredicts ethene by a factor of 6-10, underpredicts iso-butene by a factor of 2, and overpredicts iso-butyraldehyde by a factor of 2. Reaction path and sensitivity analyses were carried out to identify the reactions responsible for the observed inadequacy. The rates of iso-butanol hydrogen atom abstraction by OH radical and the beta-scission reactions of hydroxybutyl radicals were updated based on recently published quantum calculation results. Significant improvements were achieved in predicting ignition delay at high pressures (25 and 30 bar) and the species concentrations of ethene and iso-butene. However, the updated mechanism still overpredicts iso-butyraldehyde concentrations. Also, the updated mechanism degrades the prediction in ignition delay at lower pressure (15 bar) compared to the original mechanism developed by Sarathy et al.

  6. Intermediate species measurement during iso-butanol auto-ignition

    KAUST Repository

    Ji, Weiqi; Zhang, Peng; He, Tanjin; Wang, Zhi; Tao, Ling; He, Xin; Law, Chung K.

    2015-01-01

    © 2015 The Combustion Institute.Published by Elsevier Inc. All rights reserved. This work presents the time histories of intermediate species during the auto-ignition of iso-butanol at high pressure and intermediate temperature conditions obtained using a rapid compression machine and recently developed fast sampling system. Iso-butanol ignition delays were acquired for iso-butanol/O2 mixture with an inert/O2 ratio of 7.26, equivalence ratio of 0.4, in the temperature range of 840-950 K and at pressure of 25 bar. Fast sampling and gas chromatography were used to acquire and quantify the intermediate species during the ignition delay of the same mixture at P = 25.3 bar and T = 905 K. The ignition delay times and quantitative measurements of the mole fraction time histories of methane, ethene, propene, iso-butene, iso-butyraldehyde, iso-butanol, and carbon monoxide were compared with predictions from the detailed mechanisms developed by Sarathy et al., Merchant et al., and Cai et al. It is shown that while the Sarathy mechanism well predicts the overall ignition delay time, it overpredicts ethene by a factor of 6-10, underpredicts iso-butene by a factor of 2, and overpredicts iso-butyraldehyde by a factor of 2. Reaction path and sensitivity analyses were carried out to identify the reactions responsible for the observed inadequacy. The rates of iso-butanol hydrogen atom abstraction by OH radical and the beta-scission reactions of hydroxybutyl radicals were updated based on recently published quantum calculation results. Significant improvements were achieved in predicting ignition delay at high pressures (25 and 30 bar) and the species concentrations of ethene and iso-butene. However, the updated mechanism still overpredicts iso-butyraldehyde concentrations. Also, the updated mechanism degrades the prediction in ignition delay at lower pressure (15 bar) compared to the original mechanism developed by Sarathy et al.

  7. Study of vanadium(IV) species and corresponding electrochemical performance in concentrated sulfuric acid media

    International Nuclear Information System (INIS)

    Wu Xuewen; Wang Jinjin; Liu Suqin; Wu Xiongwei; Li Sha

    2011-01-01

    Highlights: → Two new UV/Vis absorbance peaks are found in V(IV) sulfuric acid solutions. → We give the structural information on the new corresponding V(IV) species. → Reaction route is given with increasing sulfuric acid and V(IV) concentrations. → We find V(IV) species corresponding to the reversible electrochemical reaction. → A mixed-valence intermediate is invoked in the reversible reaction. - Abstract: The vanadium(IV) ion is found to form the [VO(SO 4 )(H 2 O) 4 ].H 2 O complex, as well as the dimer, [VO(H 2 O) 3 ] 2 (μ-SO 4 ) 2 , in concentrated H 2 SO 4 media. Their formation mechanisms were investigated by UV-Visible spectroscopy (UV-Vis), Raman spectroscopy, X-ray diffraction (XRD), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). UV-Vis spectroscopy study showed that [VO(SO 4 )(H 2 O) 4 ].H 2 O concentration in H 2 SO 4 solution was proportional to concentrations of VO 2+ and SO 4 2- . The increased deviation from the near centrosymmetry of the octahedral complexes is due to the replacement of an equatorial water oxygen in [VO(H 2 O) 5 ]SO 4 by a sulfate oxygen in [VO(SO 4 )(H 2 O) 4 ].H 2 O. The dimer shows symmetrical structure, which correlates very well with non-activity in UV-Vis spectroscopic analysis. Structural information on both vanadium(IV) species can be confirmed by Raman and XRD measurements of crystals from the supersaturated solution of VOSO 4 in 1 M, 6 M and 12 M sulfuric acid. A solution of vanadium(IV) (0.05 M) in 12 M H 2 SO 4 , in which the vanadium(IV) species is [VO(H 2 O) 3 ] 2 (μ-SO 4 ) 2 , exhibits a reversible redox behavior near 1.14 V (vs. SCE) on the carbon paper electrode.

  8. Warm season chloride concentrations in stream habitats of freshwater mussel species at risk

    International Nuclear Information System (INIS)

    Todd, Aaron K.; Kaltenecker, M. Georgina

    2012-01-01

    Warm season (May–October) chloride concentrations were assessed in stream habitats of freshwater mussel species at risk in southern Ontario, Canada. Significant increases in concentrations were observed at 96% of 24 long-term (1975–2009) monitoring sites. Concentrations were described as a function of road density indicating an anthropogenic source of chloride. Linear regression showed that 36% of the variation of concentrations was explained by road salt use by the provincial transportation ministry. Results suggest that long-term road salt use and retention is contributing to a gradual increase in baseline chloride concentrations in at risk mussel habitats. Exposure of sensitive mussel larvae (glochidia) to increasing chloride concentrations may affect recruitment to at risk mussel populations. - Highlights: ► Warm season chloride concentrations were assessed in habitats of mussel species at risk. ► Concentrations increased significantly at 96% of 24 long-term monitoring sites. ► Concentrations increased with increases in road density and road salt use. ► Retention of road salt likely contributed to elevated warm season concentrations. ► Glochidia exposure to increasing concentrations may affect mussel reproduction. - Warm season chloride concentrations increased in southern Ontario streams with road salt use, such that reproduction of freshwater mussel species at risk may be affected.

  9. Measured and calculated NO2 concentrations in Amsterdam in 2008

    International Nuclear Information System (INIS)

    Wesseling, J.P.; Nguyen, P.L.; Van der Zee, S.

    2010-08-01

    Calculations using the Dutch standard calculation method for air quality in urban streets performed for 38 streets in Amsterdam in 2008 yield, on average, lower Nitrogen dioxide concentrations than measurements at those locations. This follows from research by the RIVM and the Public Health Service of Amsterdam (GGD Amsterdam). The average difference between measured and calculated concentrations is 11 %. At measuring locations of the National Air Quality Measuring Network in the Netherlands no significant underestimation of concentrations by the model is observed. The research was performed by the Dutch ministry of Housing, Spatial Planning en the Environment (VROM). The air quality in the streets that were investigated is mainly determined by emissions from local traffic. The measurements have been performed during thirteen periods of four weeks each, using so called 'Palmes' diffusion tubes. These measurements have been calibrated using the European reference method that is operational in the permanent measuring stations of the GGD Amsterdam. The calculations were performed using the geometry of the roads and information of the traffic at the measuring locations. Part of the differences can be explained, as some locations are not within the scope of the model. In these situations the model is known to perform slightly less. Apart from local traffic, other sources, like shipping, also contribute to the NO2 background concentrations in streets in Amsterdam. Sources that have only globally been included in the calculation of this background concentration may influence concentrations at specific locations. Further studies on this subject will be conducted in 2010. [nl

  10. Effects of Barium Concentration on Oropharyngeal Swallow Timing Measures

    OpenAIRE

    Stokely, Shauna L.; Molfenter, Sonja M.; Steele, Catriona M.

    2013-01-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between “thin” (40 % w/v concentration) and “ultrathin” (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; ...

  11. Variation of pH-measurement in platelet concentrates

    NARCIS (Netherlands)

    van der Meer, P. F.; van Zanten, A. P.; Pietersz, R. N.; Reesink, H. W.

    2001-01-01

    To measure pH in platelet concentrates, blood gas analysers with different calibration principles may be used. In this study, variances observed in pH measurements with two types of blood gas analysers were investigated. pH was measured in crystalloid solutions (platelet additive solution (PAS-II),

  12. Effects of barium concentration on oropharyngeal swallow timing measures.

    Science.gov (United States)

    Stokely, Shauna L; Molfenter, Sonja M; Steele, Catriona M

    2014-02-01

    Videofluoroscopy is commonly used for evaluating oropharyngeal swallowing but requires radiopaque contrast (typically barium). Prior studies suggest that some aspects of swallowing, including timing measures of oral and pharyngeal bolus transit, vary depending on barium concentration. The aim of our study was to identify timing differences in healthy swallowing between "thin" (40 % w/v concentration) and "ultrathin" (22 % w/v concentration) barium solutions. Twenty healthy adults (Ten women; mean age = 31 years) each performed a series of three noncued 5-ml swallows each of ultrathin and thin liquid barium solutions in videofluoroscopy. Timing measures were compared between barium concentrations using a mixed-model ANOVA. The measures of interest were stage transition duration, pharyngeal transit time, and duration of upper esophageal sphincter opening. Significant differences were observed in the timing measures of swallowing with respect to barium concentration. In all cases, longer durations were seen with the higher barium concentration. Barium concentration influences timing parameters in healthy swallowing, even between ultrathin and thin concentrations. Clinicians need to understand and control for the impact of different barium stimuli on swallowing physiology.

  13. An inverse radiation model for optical determination of temperature and species concentration: Development and validation

    DEFF Research Database (Denmark)

    Ren, Tao; Modest, Michael F.; Fateev, Alexander

    2015-01-01

    2010 (Rothman et al. (2010) [1]), which contains line-by-line (LBL) information for several combustion gas species, such as CO2 and H2O, was used to predict gas spectral transmissivities. The model was validated by retrieving temperatures and species concentrations from experimental CO2 and H2O...

  14. Aquatic respiration rate measurements at low oxygen concentrations.

    Directory of Open Access Journals (Sweden)

    Moritz Holtappels

    Full Text Available Despite its huge ecological importance, microbial oxygen respiration in pelagic waters is little studied, primarily due to methodological difficulties. Respiration measurements are challenging because of the required high resolution of oxygen concentration measurements. Recent improvements in oxygen sensing techniques bear great potential to overcome these limitations. Here we compare 3 different methods to measure oxygen consumption rates at low oxygen concentrations, utilizing amperometric Clark type sensors (STOX, optical sensors (optodes, and mass spectrometry in combination with (18-18O2 labeling. Oxygen concentrations and consumption rates agreed well between the different methods when applied in the same experimental setting. Oxygen consumption rates between 30 and 400 nmol L(-1 h(-1 were measured with high precision and relative standard errors of less than 3%. Rate detection limits in the range of 1 nmol L(-1 h(-1 were suitable for rate determinations in open ocean water and were lowest at the lowest applied O2 concentration.

  15. Measurement of radon activity concentrations in air of Tuzla city

    International Nuclear Information System (INIS)

    Adrovic, F.; Fazlic, R.; Tresnjo, Z.

    2004-01-01

    The survey was conducted over one year in the area of Tuzla city and its surrounding. At the measuring locations there were registered Daily and seasonal variations in outdoor radon concentration were observed, with average values lying within the region of 9 - 30 Bq/m 3 . The results of the measurements will be included in the concentration map of radon activity in Bosnia and Herzegovina, which is under preparation. (P.A.)

  16. Effect of atmospheric carbon dioxide concentration on the cultivation of bovine Mycoplasma species.

    Science.gov (United States)

    Lowe, J L; Fox, L K; Enger, B D; Progar, A Adams; Gay, J M

    2018-05-01

    Recommendations for bovine mycoplasma culture CO 2 concentrations are varied and were not empirically derived. The objective of this study was to determine whether the growth measures of bovine mycoplasma isolates differed when incubated in CO 2 concentrations of 10 or 5% or in candle jars (2.7 ± 0.2% CO 2 ). Growth of Mycoplasma bovis (n = 22), Mycoplasma californicum (n = 18), and other Mycoplasma spp. (n = 10) laboratory isolates was evaluated. Isolate suspensions were standardized to approximately 10 8 cfu/mL and serially diluted in pasteurized whole milk to achieve test suspensions of 10 2 and 10 6 cfu/mL. One hundred microliters of each test dilution was spread in duplicate onto the surface of a modified Hayflick's agar plate. Colony growth was enumerated on d 3, 5, and 7 of incubation. A mixed linear model included the fixed effects of CO 2 treatment (2.7, 5, or 10%), species, day (3, 5, or 7), and their interactions, with total colony counts as the dependent variable. Carbon dioxide concentration did not significantly affect overall mycoplasma growth differences, but differences between species and day were present. Colony counts (log 10 cfu/mL) of M. bovis were 2.6- and 1.6-fold greater than M. californicum and other Mycoplasma spp., respectively. Growth at 7 d of incubation was greater than d 3 and 5 for all species. These findings were confirmed using field isolates (n = 98) from a commercial veterinary diagnostic laboratory. Binary growth responses (yes/no) of the field isolates were not different between CO 2 treatments but did differ between species and day of incubation. On average, 57% of all field isolates were detected by 3 d of incubation compared with 93% on d 7. These results suggest that the range of suitable CO 2 culture conditions and incubation times for the common mastitis-causing Mycoplasma spp. may be broader than currently recommended. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Rhabdomyolysis and Artifactual Increase in Plasma Bicarbonate Concentration in an Amazon Parrot (Amazona species).

    Science.gov (United States)

    Leissinger, Mary K; Johnson, James G; Tully, Thomas N; Gaunt, Stephen D

    2017-09-01

    A 7-year-old male Amazon parrot housed outdoors presented with acute collapse, marked lethargy, and open-mouth breathing. The patient had stiffness of the pectoral muscles, and petechiation and ecchymosis noted around the eyes and beneath the mandible. Laboratory data revealed markedly increased aspartate aminotransferase, creatine kinase, and lactate dehydrogenase activity consistent with rhabdomyolysis, as well as markedly increased plasma bicarbonate concentration. Marked clinical improvement and resolution of laboratory abnormalities occurred with fluid therapy, administration of a nonsteroidal anti-inflammatory medication, and husbandry modifications, including indoor housing and dietary alteration. A spurious increase in bicarbonate measurement as documented in equine and bovine cases of rhabdomyolysis also occurred in this avian patient and must be considered for accurate interpretation of acid-base status in exotic species presenting with consistent clinical signs.

  18. Measurements of indoor radon concentration in Libyan cities

    International Nuclear Information System (INIS)

    Elarabiy, S. F.; Khalifa, M.; Misrati, N.; Chahboune, N.; Ahmed, M.

    2012-12-01

    Studies confirm that the risk of exposure to indor radon is attributable to lung cancer worldwide. The relationship between radon exposure and cancer is a linear one which necessitates for need for measurements of indoor radon concentration. This paper presents the results of measurements of indoor radon in several libya cities using CR-39 plastic. The results showed that the average radon concentration in the cities of Tripoli, Al-harcha and Alrajaban were 48.8 Bg/m 3 , 51.4 Bg/m 3 and 55.5 Bg/m 3 respectively. The average indoor radon concentration in Libya is low comparing with other studies. (Author)

  19. Development of concentration measurement system in a mini-channel using a local NMR sensor

    International Nuclear Information System (INIS)

    Ogawa, Kuniyasu; Haishi, Tomoyuki

    2008-01-01

    A local NMR sensor to measure methanol concentration of fluid flowing in a mini-channel was developed. The principle of the methanol sensor is based on the chemical shift of CH and OH species under high magnetic field. The sensor consists of a planar surface coil of 0.60 mm inside diameter. Using the sensors, local methanol concentration of water-methanol mixture in the mini-channel of 3.0 mm width and 1.5 mm depth was measured. The effects of flow velocity in the channel and the gravity direction on the methanol concentration distribution in the channel were investigated experimentally. (author)

  20. Workplace aerosol mass concentration measurement using optical particle counters.

    Science.gov (United States)

    Görner, Peter; Simon, Xavier; Bémer, Denis; Lidén, Göran

    2012-02-01

    Direct-reading aerosol measurement usually uses the optical properties of airborne particles to detect and measure particle concentration. In the case of occupational hygiene, mass concentration measurement is often required. Two aerosol monitoring methods are based on the principle of light scattering: optical particle counting (OPC) and photometry. The former analyses the light scattered by a single particle, the latter by a cloud of particles. Both methods need calibration to transform the quantity of scattered light detected into particle concentration. Photometers are simpler to use and can be directly calibrated to measure mass concentration. However, their response varies not only with aerosol concentration but also with particle size distribution, which frequently contributes to biased measurement. Optical particle counters directly measure the particle number concentration and particle size that allows assessment of the particle mass provided the particles are spherical and of known density. An integrating algorithm is used to calculate the mass concentration of any conventional health-related aerosol fraction. The concentrations calculated thus have been compared with simultaneous measurements by conventional gravimetric sampling to check the possibility of field OPC calibration with real workplace aerosols with a view to further monitoring particle mass concentration. Aerosol concentrations were measured in the food industry using the OPC GRIMM® 1.108 and the CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) aerosol samplers while meat sausages were being brushed and coated with calcium carbonate. Previously, the original OPC inlet had been adapted to sample inhalable aerosol. A mixed aerosol of calcium carbonate and fungi spores was present in the workplace. The OPC particle-size distribution and an estimated average particle density of both aerosol components were used to calculate the mass concentration. The inhalable and respirable aerosol fractions

  1. Validation of image cytometry for sperm concentration measurement

    DEFF Research Database (Denmark)

    Egeberg Palme, Dorte L.; Johannsen, Trine Holm; Petersen, Jørgen Holm

    2017-01-01

    Sperm concentration is an essential parameter in the diagnostic evaluation of men from infertile couples. It is usually determined by manual counting using a hemocytometer, and is therefore both laborious and subjective. We have earlier shown that a newly developed image cytometry (IC) method may...... be used to determine sperm concentration. Here we present a validation of the IC method by analysis of 4010 semen samples. There was high agreement between IC and manual counting at sperm concentrations above 3 mill/ml and in samples with concentrations above 12 mill/ml the two methods can be used...... a lower coefficient of variation than the manual method (5% vs 10%), indicating a better precision of the IC method. In conclusion, measurement of sperm concentration by IC can be used at concentrations above 3 mill/ml and seems more accurate and precise than manual counting, making it an attractive...

  2. Traceable measurements of the activity concentration in air

    CERN Document Server

    Paul, A; Forkel-Wirth, Doris; Müller, A; Marcos, A

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC/sub 2/ and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring alpha -particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes. (10 refs).

  3. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  4. Intercomparison of different instruments that measure radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, M.; Iida, T.; Ikebe, Y.

    1987-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap technique, a flow-type ionization chamber (pulse-counting technique), a two-filter method, an electrostatic collection method and a passive integrating radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq/m/sup 3/ (in outdoor air) to 110 Bq/m/sup 3/ (in indoor air). The results obtained from these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling technique was about 52% of radon concentrations

  5. Traceable measurements of the activity concentration in air

    International Nuclear Information System (INIS)

    Paul, Annette; Honig, Anja; Forkel-Wirth, Doris; Mueller, Andre; Marcos, Alicia

    2002-01-01

    The nuclear reactions induced by high energetic protons in heavy targets such as UC 2 and ThC cause a particular, complex radiation protection task at facilities like ISOLDE: the measurement of a mixture of different isotopes of the radioactive noble gas radon and the radon progenies in air. The knowledge of their respective activity concentration is fundamental for exposure assessments. Due to the complex mixture of activity concentrations in air, its precise determination is quite difficult. Therefore, a new procedure for taking reference samples was developed and implemented for the traceable measurement of the activity concentration of radioactive ions (e.g., radon progenies) in air. This technique is combined by measuring α-particles with a multi-wire ionization chamber for the parallel on-line determination of the activity concentration of different radon isotopes

  6. Concentration of arsenic in water, sediments and fish species from naturally contaminated rivers.

    Science.gov (United States)

    Rosso, Juan José; Schenone, Nahuel F; Pérez Carrera, Alejo; Fernández Cirelli, Alicia

    2013-04-01

    Arsenic (As) may occur in surface freshwater ecosystems as a consequence of both natural contamination and anthropogenic activities. In this paper, As concentrations in muscle samples of 10 fish species, sediments and surface water from three naturally contaminated rivers in a central region of Argentina are reported. The study area is one of the largest regions in the world with high As concentrations in groundwater. However, information of As in freshwater ecosystems and associated biota is scarce. An extensive spatial variability of As concentrations in water and sediments of sampled ecosystems was observed. Geochemical indices indicated that sediments ranged from mostly unpolluted to strongly polluted. The concentration of As in sediments averaged 6.58 μg/g ranging from 0.23 to 59.53 μg/g. Arsenic in sediments barely followed (r = 0.361; p = 0.118) the level of contamination of water. All rivers showed high concentrations of As in surface waters, ranging from 55 to 195 μg/L. The average concentration of As in fish was 1.76 μg/g. The level of contamination with As differed significantly between species. Moreover, the level of bioaccumulation of As in fish species related to the concentration of As in water and sediments also differed between species. Whilst some fish species seemed to be able to regulate the uptake of this metalloid, the concentration of As in the large catfish Rhamdia quelen mostly followed the concentration of As in abiotic compartments. The erratic pattern of As concentrations in fish and sediments regardless of the invariable high levels in surface waters suggests the existence of complex biogeochemical processes behind the distribution patterns of As in these naturally contaminated ecosystems.

  7. Genetic variability of concentration of microelements in wild sunflower species and hybrids

    Directory of Open Access Journals (Sweden)

    Kastori Rudolf R.

    2010-01-01

    Full Text Available The aim of this work was to investigate genetic specificity of sunflower nutrition with microelements. Therefore, concentrations of essential (Zn, B, Mn, Cu, Fe and Ni and non-essential (Cr, Al, Cd, As, Pb and Ba micronutrients were analyzed. Five sunflower hybrids the most grown in Serbia and different populations of wild sunflower species originating from North America: Helianthus neglectus Heiser (3, Helianthus agrophyllus T&G (3, Helianthus petiolaris Nutt. (2, Helianthus annuus L. (4 were included in the experiment. Populations of wild sunflower species and hybrids differed significantly with respect to the concentration of analyzed elements. Manganese concentration was significantly higher in hybrids than in wild species. In all genotypes Fe, B and Mn had the highest concentration. Coefficient of variation of microelement concentration depended on genotype and particular element. In wild populations, for essential microelements, it was between 3.7 and 59.5, whereas in hybrids it varied from 10.0 to 48.8. Coefficient of variation of concentration of non-essential microelements in wild populations varied from 7.7 to 73.8, and in hybrids from 15.1 to 48.8. Average coefficient of variation in both wild species and hybrids was the lowest for Mn and Pb. It was the highest for Cr, Ni, and Zn in hybrids and for Cd, Ni, and Cr in wild species. The results suggest that genetic specificity with respect to uptake of microelements in wild species and hybrids is highly expressed. Broad genetic variability of concentrations of microelements in wild species and hybrids indicate that their reactions to deficiency and/or excess of those elements probably are not the same either. This finding may be used in breeding process aimed specifically at improvement of tolerance and capacity to accumulate microelements in sunflower. Phytoremediation technology designed to reduce the amount of microelements in the soil could thus be advanced by utilization of such

  8. Reflective measurement of water concentration using millimeter wave illumination

    Science.gov (United States)

    Sung, Shijun; Bennett, David; Taylor, Zachary; Bajwa, Neha; Tewari, Priyamvada; Maccabi, Ashkan; Culjat, Martin; Singh, Rahul; Grundfest, Warren

    2011-04-01

    THz and millimeter wave technology have shown the potential to become a valuable medical imaging tool because of its sensitivity to water and safe, non-ionizing photon energy. Using the high dielectric constant of water in these frequency bands, reflectionmode THz sensing systems can be employed to measure water content in a target with high sensitivity. This phenomenology may lead to the development of clinical systems to measure the hydration state of biological targets. Such measurements may be useful in fast and convenient diagnosis of conditions whose symptoms can be characterized by changes in water concentration such as skin burns, dehydration, or chemical exposure. To explore millimeter wave sensitivity to hydration, a reflectometry system is constructed to make water concentration measurements at 100 GHz, and the minimum detectable water concentration difference is measured. This system employs a 100 GHz Gunn diode source and Golay cell detector to perform point reflectivity measurements of a wetted polypropylene towel as it dries on a mass balance. A noise limited, minimum detectable concentration difference of less than 0.5% by mass can be detected in water concentrations ranging from 70% to 80%. This sensitivity is sufficient to detect hydration changes caused by many diseases and pathologies and may be useful in the future as a diagnostic tool for the assessment of burns and other surface pathologies.

  9. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement

    International Nuclear Information System (INIS)

    Acena, M. L.; Crespo, M. T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs

  10. Comparison of predicted and measured variations of indoor radon concentration

    International Nuclear Information System (INIS)

    Arvela, H.; Voutilainen, A.; Maekelaeinen, I.; Castren, O.; Winqvist, K.

    1988-01-01

    Prediction of the variations of indoor radon concentration were calculated using a model relating indoor radon concentration to radon entry rate, air infiltration and meteorological factors. These calculated variations have been compared with seasonal variations of 33 houses during 1-4 years, with winter-summer concentration ratios of 300 houses and the measured diurnal variation. In houses with a slab in ground contact the measured seasonal variations are quite often in agreement with variations predicted for nearly pure pressure difference driven flow. The contribution of a diffusion source is significant in houses with large porous concrete walls against the ground. Air flow due to seasonally variable thermal convection within eskers strongly affects the seasonal variations within houses located thereon. Measured and predicted winter-summer concentration ratios demonstrate that, on average, the ratio is a function of radon concentration. The ratio increases with increasing winter concentration. According to the model the diurnal maximum caused by a pressure difference driven flow occurs in the morning, a finding which is in agreement with the measurements. The model presented can be used for differentiating between factors affecting radon entry into houses. (author)

  11. IASI measurements of reactive trace species in biomass burning plumes

    Directory of Open Access Journals (Sweden)

    P.-F. Coheur

    2009-08-01

    Full Text Available This work presents observations of a series of short-lived species in biomass burning plumes from the Infrared Atmospheric Sounding Interferometer (IASI, launched onboard the MetOp-A platform in October 2006. The strong fires that have occurred in the Mediterranean Basin – and particularly Greece – in August 2007, and those in Southern Siberia and Eastern Mongolia in the early spring of 2008 are selected to support the analyses. We show that the IASI infrared spectra in these fire plumes contain distinctive signatures of ammonia (NH3, ethene (C2H4, methanol (CH3OH and formic acid (HCOOH in the atmospheric window between 800 and 1200 cm−1, with some noticeable differences between the plumes. Peroxyacetyl nitrate (CH3COOONO2, abbreviated as PAN was also observed with good confidence in some plumes and a tentative assignment of a broadband absorption spectral feature to acetic acid (CH3COOH is made. For several of these species these are the first reported measurements made from space in nadir geometry. The IASI measurements are analyzed for plume height and concentration distributions of NH3, C2H4 and CH3OH. The Greek fires are studied in greater detail for the days associated with the largest emissions. In addition to providing information on the spatial extent of the plume, the IASI retrievals allow an estimate of the total mass emissions for NH3, C2H4 and CH3OH. Enhancement ratios are calculated for the latter relative to carbon monoxide (CO, giving insight in the chemical processes occurring during the transport, the first day after the emission.

  12. Arsenic Species in Chicken Breast: Temporal Variations of Metabolites, Elimination Kinetics, and Residual Concentrations.

    Science.gov (United States)

    Liu, Qingqing; Peng, Hanyong; Lu, Xiufen; Zuidhof, Martin J; Li, Xing-Fang; Le, X Chris

    2016-08-01

    Chicken meat has the highest per capita consumption among all meat types in North America. The practice of feeding 3-nitro-4-hydroxyphenylarsonic acid (Roxarsone, Rox) to chickens lasted for more than 60 years. However, the fate of Rox and arsenic metabolites remaining in chicken are poorly understood. We aimed to determine the elimination of Rox and metabolites from chickens and quantify the remaining arsenic species in chicken meat, providing necessary information for meaningful exposure assessment. We have conducted a 35-day feeding experiment involving 1,600 chickens, of which half were control and the other half were fed a Rox-supplemented diet for the first 28 days and then a Rox-free diet for the final 7 days. We quantified the concentrations of individual arsenic species in the breast meat of 229 chickens. Rox, arsenobetaine, arsenite, monomethylarsonic acid, dimethylarsinic acid, and a new arsenic metabolite, were detected in breast meat from chickens fed Rox. The concentrations of arsenic species, except arsenobetaine, were significantly higher in the Rox-fed than in the control chickens. The half-lives of elimination of these arsenic species were 0.4-1 day. Seven days after termination of Rox feeding, the concentrations of arsenite (3.1 μg/kg), Rox (0.4 μg/kg), and a new arsenic metabolite (0.8 μg/kg) were significantly higher in the Rox-fed chickens than in the control. Feeding of Rox to chickens increased the concentrations of five arsenic species in breast meat. Although most arsenic species were excreted rapidly when the feeding of Rox stopped, arsenic species remaining in the Rox-fed chickens were higher than the background levels. Liu Q, Peng H, Lu X, Zuidhof MJ, Li XF, Le XC. 2016. Arsenic species in chicken breast: temporal variations of metabolites, elimination kinetics, and residual concentrations. Environ Health Perspect 124:1174-1181; http://dx.doi.org/10.1289/ehp.1510530.

  13. Impact of concentration and species of sulfamethoxazole and ofloxacin on their adsorption kinetics on sediments.

    Science.gov (United States)

    Wang, Peng; Zhang, Di; Zhang, Huang; Li, Hao; Ghosh, Saikat; Pan, Bo

    2017-05-01

    Antibiotics are used widely in human and veterinary medicine and are ubiquitous in environmental matrices worldwide. The influence of the concentration of antibiotics on adsorption kinetics is still unclear. This study used sulfamethoxazole (SMX) and ofloxacin (OFL) as adsorbates to investigate the adsorption kinetics on sediment affected by varying concentrations of antibiotics adsorbable species. At the experimental pH values, the major adsorbed species of SMX and OFL on sediment were SMX 0 and OFL + by hydrophobic interaction and electrostatic attraction, respectively. The apparent adsorption rate of SMX was not affected by the initial concentration and the pH values because the hydrophobic interactions were concentration-independent and charge-independent. However, the apparent adsorption rate of OFL significantly slowed down as the initial concentration increased. The adsorbed OFL + effectively neutralized the negative charges of the sediment, leading to a reduced adsorption rate of subsequent OFL + . The neutralization effect was greatly enhanced due to the increased OFL + with the increasing OFL concentration. Additionally, the apparent adsorption rate of OFL significantly increased at higher pH due to the reduced neutralization effect that resulted from the decreased OFL + and increased negative charges of the sediment surface. This study implied that the adsorption kinetics of antibiotics was greatly dominated by the concentration of adsorbable species rather than apparent overall concentration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Comparing predicted estrogen concentrations with measurements in US waters

    International Nuclear Information System (INIS)

    Kostich, Mitch; Flick, Robert; Martinson, John

    2013-01-01

    The range of exposure rates to the steroidal estrogens estrone (E1), beta-estradiol (E2), estriol (E3), and ethinyl estradiol (EE2) in the aquatic environment was investigated by modeling estrogen introduction via municipal wastewater from sewage plants across the US. Model predictions were compared to published measured concentrations. Predictions were congruent with most of the measurements, but a few measurements of E2 and EE2 exceed those that would be expected from the model, despite very conservative model assumptions of no degradation or in-stream dilution. Although some extreme measurements for EE2 may reflect analytical artifacts, remaining data suggest concentrations of E2 and EE2 may reach twice the 99th percentile predicted from the model. The model and bulk of the measurement data both suggest that cumulative exposure rates to humans are consistently low relative to effect levels, but also suggest that fish exposures to E1, E2, and EE2 sometimes substantially exceed chronic no-effect levels. -- Highlights: •Conservatively modeled steroidal estrogen concentrations in ambient water. •Found reasonable agreement between model and published measurements. •Model and measurements agree that risks to humans are remote. •Model and measurements agree significant questions remain about risk to fish. •Need better understanding of temporal variations and their impact on fish. -- Our model and published measurements for estrogens suggest aquatic exposure rates for humans are below potential effect levels, but fish exposure sometimes exceeds published no-effect levels

  15. Continuous measurement of uranium concentrations with the laser spark

    International Nuclear Information System (INIS)

    Gutmacher, R.G.; Cremers, D.A.; Wachter, J.R.

    1987-01-01

    Laser-induced breakdown spectroscopy has been applied to the continuous determination of uranium concentrations between 0.1 and 300 g/L in flowing solutions. The technique is rapid, noninvasive, and unaffected by radioactivity. A concentration of 10 g/L was measured with 0.8% precision in 3 min. Substances that absorb at the laser wavelength, suspended materials, and variations in the acidity of the solution have little or no effect on the results. High concentrations of zirconium, cadmium, aluminum, or stainless steel in solution do not interfere

  16. Measurements in Concentrated Sun using a Remote Controlled Robot

    Directory of Open Access Journals (Sweden)

    Dan Floroian

    2013-04-01

    Full Text Available Nowdays, using the concentrated sunlight is a big issue because the amount of energy is very high and the light is concentrated in a very small area. The main problem in this situation is the heating, and in order to make safe measurements a remote controlled robot is needed. After that, a remote controlled robot will assume the duty of protect the measured sample and to expose it for a precise time to the concentrated sun in order to reduce heating of the sample. For easy operating, and for automatize the process, all the duties, starting with initial conditions, continuing with triggering the measurements, and conditioning the signals and finalizing with data saving must be assured by the robot.

  17. Measurement of average radon gas concentration at workplaces

    International Nuclear Information System (INIS)

    Kavasi, N.; Somlai, J.; Kovacs, T.; Gorjanacz, Z.; Nemeth, Cs.; Szabo, T.; Varhegyi, A.; Hakl, J.

    2003-01-01

    In this paper results of measurement of average radon gas concentration at workplaces (the schools and kindergartens and the ventilated workplaces) are presented. t can be stated that the one month long measurements means very high variation (as it is obvious in the cases of the hospital cave and the uranium tailing pond). Consequently, in workplaces where the expectable changes of radon concentration considerable with the seasons should be measure for 12 months long. If it is not possible, the chosen six months period should contain summer and winter months as well. The average radon concentration during working hours can be differ considerable from the average of the whole time in the cases of frequent opening the doors and windows or using artificial ventilation. (authors)

  18. TXRF 'measurements' of concentration distribution below the detection limit

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Mrowczynski, S.; Pajek, M.

    2000-01-01

    We demonstrate that a shape of the concentration distribution of the element in a set of samples, as measured by the TXRF method, can be determined even for the concentrations below the detection limit (DL). This can be done, when the measurements reporting the concentration below DL level are included properly in the analysis of the results. The method developed for such correction is presented and discussed. It is demonstrated that this correction is particularly important when the studied concentrations are close to the DL level of the method, which is a common case for TXRF. In the paper a precision of the developed correction is discussed in details, by using the results of numerical simulations of experiments for different concentration distributions and number of performed measurements. It is demonstrated that the factor, which limits the accuracy of the correction, is the number of measurements, not the correction procedure itself. The applicability and importance of the developed correction is demonstrated for routine TXRF analysis of different types of samples of bio-medical interest. (author)

  19. QA/QC For Radon Concentration Measurement With Charcoal Canister

    International Nuclear Information System (INIS)

    Pantelic, G.; Zivanovic, M.; Rajacic, M.; Krneta Nikolic, J.; Todorovic, D.

    2015-01-01

    The primary concern of any measuring of radon or radon progeny must be the quality of the results. A good quality assurance program, when properly designed and diligently followed, ensures that laboratory staff will be able to produce the type and quality of measurement results which is needed and expected. Active charcoal detectors are used for testing the concentration of radon in dwellings. The method of measurement is based on radon adsorption on coal and measurement of gamma radiation of radon daughters. Upon closing the detectors, the measurement was carried out after achieving the equilibrium between radon and its daughters (at least 3 hours) using NaI or HPGe detector. Radon concentrations as well as measurement uncertainties were calculated according to US EPA protocol 520/5-87-005. Detectors used for the measurements were calibrated by 226Ra standard of known activity in the same geometry. Standard and background canisters are used for QA and QC, as well as for the calibration of the measurement equipment. Standard canister is a sealed canister with the same matrix and geometry as the canisters used for measurements, but with the known activity of radon. Background canister is a regular radon measurement canister, which has never been exposed. The detector background and detector efficiency are measured to ascertain whether they are within the warning and acceptance limits. (author).

  20. Fissile materials in solution concentration measured by active neutron interrogation

    International Nuclear Information System (INIS)

    Romeyer Dherbey, J.; Passard, Ch.; Cloue, J.; Bignan, G.

    1993-01-01

    The use of the active neutron interrogation to measure the concentration of plutonium contained in flow solutions is particularly interesting for fuel reprocessing plants. Indeed, this method gives a signal which is in a direct relation with the fissile materials concentration. Moreover, it is less sensitive to the gamma dose rate than the other nondestructive methods. Two measure methods have been evolved in CEA. Their principles are given into details in this work. The first one consists to detect fission delayed neutrons induced by a 252 Cf source. In the second one fission prompt neutrons induced by a neutron generator of 14 MeV are detected. (O.M.)

  1. Measurement of radon concentration in water with Lucas cell detector

    International Nuclear Information System (INIS)

    Machaj, B.; Pienkos, J.P.

    2003-01-01

    A method for the measurement of radon concentration in water is presented based on flushing a water sample with air in a closed loop with the Lucas cell as alpha radiation detector. The main feature of the method is washing radon away from the larger sample of water (0.75 l) to a small volume of air, approximately 0.5 l, thanks to which a high radon concentration in air and a considerable sensitivity of measurement is achieved. Basic relations and results of measurements of a model of a gauge is given. The estimated measuring sensitivity (S) is 8.5 (cpm)/(Bq/l). The random error due to the statistical fluctuations of count rate at radon concentrations 1,10, 100, 1000, 10000 Bq/l is 11, 3.6, 1.1, 0.4, 0.1% correspondingly at a counting (measuring) time of 10 min. The minimum detectable radon concentration in water is 0.11 Bq/l. (author)

  2. Derived concentration factors for caesium-137 in edible species of North Sea fish

    International Nuclear Information System (INIS)

    Steele, A.K.

    1990-01-01

    Concentration factor (CF=Bq kg -1 fillet/Bg kg -1 filtered sea water) values for 137 Cs in fillets of cod (Gadus morhua), haddock (Merlanogrammus aeglefinus), plaice (Pleuronectes platessa) and whiting (Merlangius merlangius), were derived from fish and filtered seawater concentrations. Samples were collected in twelve sampling boxes in the North Sea over an eight-year period - 1978-1985. The range of results with species, between species, and between surveys are discussed. Mean CF values of 92, 58, 39 and 150 were found in cod, haddock, plaice and whiting respectively. These support the International Atomic Energy Authority recommended CF value of 100 for fish in generalised dose assessments. (author)

  3. Measurement of plasma homovanillic acid concentrations in schizophrenic patients.

    Science.gov (United States)

    Kaminski, R; Powchick, P; Warne, P A; Goldstein, M; McQueeney, R T; Davidson, M

    1990-01-01

    1. Several lines of evidence suggest that abnormalities of central dopaminergic transmission may be involved in the expression of some schizophrenic symptoms. However, elucidation of the role of dopamine (DA) in schizophrenia has eluded investigative efforts partially because no accurate and easily repeatable measure of brain DA activity exists. 2. The development of a technique to measure homovanillic acid in plasma has offered the possibility of performing serial measurements of this major DA metabolite. 3. Assuming that plasma homovanillic acid (PHVA) concentrations is an index of brain DA activity, measurement of PHVA can play a role in elucidating the DA abnormality in schizophrenia. 4. Results to date suggest that plasma homovanillic acid concentrations are lower in chronic schizophrenic patients compared to normal controls, and that PHVA values correlate with schizophrenic symptom severity. 5. In addition, PHVA levels were shown to initially rise and subsequently decline during chronic neuroleptic administration in treatment responsive but not in treatment refractory schizophrenic patients.

  4. Fiber Optic Displacement Sensor for Measuring Cholesterol Concentration

    Directory of Open Access Journals (Sweden)

    Moh. Budiyanto

    2017-11-01

    Full Text Available A simple design of a cholesterol concentration detection is proposed and demonstrated using a fiber optic displacement sensor based on an intensity modulation technique. The proposed sensor uses a bundled plastic optical fiber (POF as a probe in conjunction with a flat mirror as a target. It is obtained that the peak voltage reduces with increasing cholesterol concentration. The sensor is capable of measuring the cholesterol concentration ranging from 0 to 300 ppm in a distilled water with a measured sensitivity of 0.01 mV/ppm, a linearity of more than 99.62 % and a resolution of 3.9188 ppm. The proposed sensor also shows a high degree of stability and good repeatability. The simplicity of design, accuracy, flexible dynamic range, and the low cost of fabrication are favorable attributes of the sensor and beneficial for real- field applications. Fiber optic sensors

  5. Measurements of radon activity concentrations in air at Niska spa

    International Nuclear Information System (INIS)

    Adrovic, F.; Vuckovic, B.; Ninkovic, M.

    2004-01-01

    Radon activity concentrations in air were measured in the recreational-tourist center of Niska Banja. Alpha Guard PQ 2000/ MC50 instrumentation (Genitron instruments, Frankfurt) was used. The observed indoor radon concentrations in the air of the Radon Hotel pool lay within the range of 0.980-1.908 kBq/m 3 and were directly dependent on the exhalation of radon from thermomineral waters. Radon concentrations were also measured outdoors, at locations for capping thermomineral water, as well as at locations for draining used water from the Radon Hotel pool. Outdoor radon concentrations as high as over 500 Bq/m 3 were observed. Gamma dose rates were measured in parallel and found to lie within the range of 72-420 nSv/h. The gamma doses correlated well with the observed radon levels. The largest gamma dose rates in air were measured in the pool of Radon Hotel and at the site where this thermomineral water is being capped

  6. Measurements of ion concentration in gasoline and diesel engine exhaust

    Science.gov (United States)

    Yu, Fangqun; Lanni, Thomas; Frank, Brian P.

    The nanoparticles formed in motor vehicle exhaust have received increasing attention due to their potential adverse health effects. It has been recently proposed that combustion-generated ions may play a critical role in the formation of these volatile nanoparticles. In this paper, we design an experiment to measure the total ion concentration in motor vehicle engine exhaust, and report some preliminary measurements in the exhaust of a gasoline engine (K-car) and a diesel engine (diesel generator). Under the experimental set-up reported in this study and for the specific engines used, the total ion concentration is ca. 3.3×10 6 cm -3 with almost all of the ions smaller than 3 nm in the gasoline engine exhaust, and is above 2.7×10 8 cm -3 with most of the ions larger than 3 nm in the diesel engine exhaust. This difference in the measured ion properties is interpreted as a result of the different residence times of exhaust inside the tailpipe/connecting pipe and the different concentrations of soot particles in the exhaust. The measured ion concentrations appear to be within the ranges predicted by a theoretical model describing the evolution of ions inside a pipe.

  7. The relationships between termite mound CH4/CO2 emissions and internal concentration ratios are species specific

    Directory of Open Access Journals (Sweden)

    H. Jamali

    2013-04-01

    Full Text Available We investigated the relative importance of CH4 and CO2 fluxes from soil and termite mounds at four different sites in the tropical savannas of northern Australia near Darwin and assessed different methods to indirectly predict CH4 fluxes based on CO2 fluxes and internal gas concentrations. The annual flux from termite mounds and surrounding soil was dominated by CO2 with large variations among sites. On a carbon dioxide equivalent (CO2-e basis, annual CH4 flux estimates from termite mounds were 5- to 46-fold smaller than the concurrent annual CO2 flux estimates. Differences between annual soil CO2 and soil CH4 (CO2-e fluxes were even greater, soil CO2 fluxes being almost three orders of magnitude greater than soil CH4 (CO2-e fluxes at site. The contribution of CH4 and CO2 emissions from termite mounds to the total CH4 and CO2 emissions from termite mounds and soil in CO2-e was less than 1%. There were significant relationships between mound CH4 flux and mound CO2 flux, enabling the prediction of CH4 flux from measured CO2 flux; however, these relationships were clearly termite species specific. We also observed significant relationships between mound flux and gas concentration inside mound, for both CH4 and CO2, and for all termite species, thereby enabling the prediction of flux from measured mound internal gas concentration. However, these relationships were also termite species specific. Using the relationship between mound internal gas concentration and flux from one species to predict mound fluxes from other termite species (as has been done in the past would result in errors of more than 5-fold for mound CH4 flux and 3-fold for mound CO2 flux. This study highlights that CO2 fluxes from termite mounds are generally more than one order of magnitude greater than CH4 fluxes. There are species-specific relationships between CH4 and CO2 fluxes from a mound, and between the inside mound concentration of a gas and the mound flux emission of the

  8. The relationship between termite mound CH4/CO2 emissions and internal concentration ratios are species specific

    Science.gov (United States)

    Jamali, H.; Livesley, S. J.; Hutley, L. B.; Fest, B.; Arndt, S. K.

    2012-12-01

    1. We investigated the relative importance of CH4 and CO2 fluxes from soil and termite mounds at four different sites in the tropical savannas of Northern Australia near Darwin and assessed different methods to indirectly predict CH4 fluxes based on CO2 fluxes and internal gas concentrations. 2. The annual flux from termite mounds and surrounding soil was dominated by CO2 with large variations among sites. On a CO2-e basis, annual CH4 flux estimates from termite mounds were 5- to 46-fold smaller than the concurrent annual CO2 flux estimates. Differences between annual soil CO2 and soil CH4 (CO2-e) fluxes were even greater, soil CO2 fluxes being almost three orders of magnitude greater than soil CH4 (CO2-e) fluxes at site. 3. There were significant relationships between mound CH4 flux and mound CO2 flux, enabling the prediction of CH4 flux from measured CO2 flux, however, these relationships were clearly termite species specific. 4. We also observed significant relationships between mound flux and gas concentration inside mound, for both CH4 and CO2, and for all termite species, thereby enabling the prediction of flux from measured mound internal gas concentration. However, these relationships were also termite species specific. Using the relationship between mound internal gas concentration and flux from one species to predict mound fluxes from other termite species (as has been done in past) would result in errors of more than 5-fold for CH4 and 3-fold for CO2. 5. This study highlights that CO2 fluxes from termite mounds are generally more than one order of magnitude greater than CH4 fluxes. There are species-specific relationships between CH4 and CO2 fluxes from a~mound, and between the inside mound concentration of a gas and the mound flux emission of the same gas, but these relationships vary greatly among termite species. Consequently, there is no generic relationship that will allow for the prediction of CH4 fluxes from termite mounds of all species.

  9. The relationships between termite mound CH4/CO2 emissions and internal concentration ratios are species specific

    Science.gov (United States)

    Jamali, H.; Livesley, S. J.; Hutley, L. B.; Fest, B.; Arndt, S. K.

    2013-04-01

    We investigated the relative importance of CH4 and CO2 fluxes from soil and termite mounds at four different sites in the tropical savannas of northern Australia near Darwin and assessed different methods to indirectly predict CH4 fluxes based on CO2 fluxes and internal gas concentrations. The annual flux from termite mounds and surrounding soil was dominated by CO2 with large variations among sites. On a carbon dioxide equivalent (CO2-e) basis, annual CH4 flux estimates from termite mounds were 5- to 46-fold smaller than the concurrent annual CO2 flux estimates. Differences between annual soil CO2 and soil CH4 (CO2-e) fluxes were even greater, soil CO2 fluxes being almost three orders of magnitude greater than soil CH4 (CO2-e) fluxes at site. The contribution of CH4 and CO2 emissions from termite mounds to the total CH4 and CO2 emissions from termite mounds and soil in CO2-e was less than 1%. There were significant relationships between mound CH4 flux and mound CO2 flux, enabling the prediction of CH4 flux from measured CO2 flux; however, these relationships were clearly termite species specific. We also observed significant relationships between mound flux and gas concentration inside mound, for both CH4 and CO2, and for all termite species, thereby enabling the prediction of flux from measured mound internal gas concentration. However, these relationships were also termite species specific. Using the relationship between mound internal gas concentration and flux from one species to predict mound fluxes from other termite species (as has been done in the past) would result in errors of more than 5-fold for mound CH4 flux and 3-fold for mound CO2 flux. This study highlights that CO2 fluxes from termite mounds are generally more than one order of magnitude greater than CH4 fluxes. There are species-specific relationships between CH4 and CO2 fluxes from a mound, and between the inside mound concentration of a gas and the mound flux emission of the same gas, but

  10. On the deduction of chemical reaction pathways from measurements of time series of concentrations.

    Science.gov (United States)

    Samoilov, Michael; Arkin, Adam; Ross, John

    2001-03-01

    We discuss the deduction of reaction pathways in complex chemical systems from measurements of time series of chemical concentrations of reacting species. First we review a technique called correlation metric construction (CMC) and show the construction of a reaction pathway from measurements on a part of glycolysis. Then we present two new improved methods for the analysis of time series of concentrations, entropy metric construction (EMC), and entropy reduction method (ERM), and illustrate (EMC) with calculations on a model reaction system. (c) 2001 American Institute of Physics.

  11. Laser system for measuring small changes in plasma tracer concentrations.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Galloway, R L; Roselli, R J

    1996-01-01

    The authors developed a laser-diode system that can be used for on-line optical concentration measurements in physiologic systems. Previous optical systems applied to whole blood have been hampered by artifacts introduced by red blood cells (RBCs). The system introduced here uses a commercially available filter cartridge to separate RBCs from plasma before plasma concentration measurements are made at a single wavelength. The filtering characteristics of the Cellco filter cartridge (#4007-10, German-town, MD) were adequate for use in the on-line measurement system. The response time of the filter cartridge was less than 40 seconds, and the sieving characteristics of the filter for macromolecules were excellent, with filtrate-to-plasma albumin ratios of 0.98 +/- 0.11 for studies in sheep and 0.94 +/- 0.15 for studies in dogs. The 635-nm laser diode system developed was shown to be more sensitive than the spectrophotometer used in previous studies (Klaesner et al., Annals of Biomedical Engineering, 1994; 22, 660-73). The new system was used to measure the product of filtration coefficient (Kfc) and reflection coefficient for albumin (delta f) in an isolated canine lung preparation. The delta fKfc values [mL/(cmH2O.min.100 g dry lung weight)] measured with the laser diode system (0.33 +/- 0.22) compared favorably with the delta fKfc obtained using a spectrophotometer (0.27 +/- 0.20) and with the Kfc obtained using the blood-corrected gravimetric method (0.32 +/- 0.23). Thus, this new optical system was shown to accurately measure plasma concentration changes in whole blood for physiologic levels of Kfc. The same system can be used with different optical tracers and different source wavelengths to make optical plasma concentration measurements for other physiologic applications.

  12. Radon concentration measurements in the desert caves of Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Mustafa, Hanan; Al-Jarallah, M.I.; Fazal-ur-Rehman; Abu-Jarad, F.

    2005-01-01

    Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm -3 . The average radon concentration in four of the caves was low in the range 74-114Bqm -3 . However, one cave showed an average radon concentration of 451Bqm -3 . Radon is not a problem for tourists in the majority of caves. However, sometimes it may imply some limitation to the working time of guides

  13. Radon concentration measurements in the desert caves of Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Al-Mustafa, Hanan [Women College, P. O. Box 838, Dammam 31113 (Saudi Arabia); Al-Jarallah, M.I. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: mibrahim@kfupm.edu.sa; Fazal-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Abu-Jarad, F. [Radiation Protection Unit, Environmental Protection Department, Saudi Aramco P.O. Box 13027, Dhahran 31311 (Saudi Arabia)

    2005-11-15

    Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm{sup -3}. The average radon concentration in four of the caves was low in the range 74-114Bqm{sup -3}. However, one cave showed an average radon concentration of 451Bqm{sup -3}. Radon is not a problem for tourists in the majority of caves. However, sometimes it may imply some limitation to the working time of guides.

  14. Estimates of CO2 traffic emissions from mobile concentration measurements

    Science.gov (United States)

    Maness, H. L.; Thurlow, M. E.; McDonald, B. C.; Harley, R. A.

    2015-03-01

    We present data from a new mobile system intended to aid in the design of upcoming urban CO2-monitoring networks. Our collected data include GPS probe data, video-derived traffic density, and accurate CO2 concentration measurements. The method described here is economical, scalable, and self-contained, allowing for potential future deployment in locations without existing traffic infrastructure or vehicle fleet information. Using a test data set collected on California Highway 24 over a 2 week period, we observe that on-road CO2 concentrations are elevated by a factor of 2 in congestion compared to free-flow conditions. This result is found to be consistent with a model including vehicle-induced turbulence and standard engine physics. In contrast to surface concentrations, surface emissions are found to be relatively insensitive to congestion. We next use our model for CO2 concentration together with our data to independently derive vehicle emission rate parameters. Parameters scaling the leading four emission rate terms are found to be within 25% of those expected for a typical passenger car fleet, enabling us to derive instantaneous emission rates directly from our data that compare generally favorably to predictive models presented in the literature. The present results highlight the importance of high spatial and temporal resolution traffic data for interpreting on- and near-road concentration measurements. Future work will focus on transport and the integration of mobile platforms into existing stationary network designs.

  15. Relationships of mercury concentrations across tissue types, muscle regions and fins for two shark species

    KAUST Repository

    O'Bryhim, Jason R.

    2017-01-31

    Mercury (Hg) exposure poses a threat to both fish and human health. Sharks are known to bioaccumulate Hg, however, little is known regarding how Hg is distributed between different tissue groups (e.g. muscle regions, organs). Here we evaluated total mercury (THg) concentrations from eight muscle regions, four fins (first dorsal, left and right pectorals, caudal-from both the inner core and trailing margin of each fin), and five internal organs (liver, kidney, spleen, heart, epigonal organ) from two different shark species, bonnethead (Sphyrna tiburo) and silky shark (Carcharhinus falciformis) to determine the relationships of THg concentrations between and within tissue groups. Total Hg concentrations were highest in the eight muscle regions with no significant differences in THg concentrations between the different muscle regions and muscle types (red and white). Results from tissue collected from any muscle region would be representative of all muscle sample locations. Total Hg concentrations were lowest in samples taken from the fin inner core of the first dorsal, pectoral, and caudal (lower lobe) fins. Mercury concentrations for samples taken from the trailing margin of the dorsal, pectoral, and caudal fins (upper and lower lobe) were also not significantly different from each other for both species. Significant relationships were found between THg concentrations in dorsal axial muscle tissue and the fin inner core, liver, kidney, spleen and heart for both species as well as the THg concentrations between the dorsal fin trailing margin and the heart for the silky shark and all other sampled tissue types for the bonnethead shark. Our results suggest that biopsy sampling of dorsal muscle can provide data that can effectively estimate THg concentrations in specific organs without using more invasive, or lethal methods.

  16. Market power in electricity markets: Beyond concentration measures

    International Nuclear Information System (INIS)

    Borenstein, S.; Bushnell, J.; Knittel, C.R.

    1999-01-01

    The wave of electricity market restructuring both within the US and abroad has brought the issue of horizontal market power to the forefront of energy policy. Traditionally, estimation and prediction of market power has relied heavily on concentration measures. In this paper, the authors discuss the weaknesses of concentration measures as a viable measure of market power in the electricity industry, and they propose an alternative method based on market simulations that take advantage of existing plant level data. The authors discuss results from previous studies they have performed, and present new results that allow for the detection of threshold demand levels where market power is likely to be a problem. In addition, the authors analyze the impact of that recent divestitures in the California electricity market will have on estimated market power. They close with a discussion of the policy implications of the results

  17. Measurement of 222Rn in soil concentrations in interstitial air

    International Nuclear Information System (INIS)

    Duenas, C.; Fernandez, M.C.; Carretero, J.; Liger, E.

    1996-01-01

    Measurements of 222 Rn soil concentrations were made by inserting stainless-steel sampling tubes into the soil. The samples of the soil interstitial air were taken in to pre-evacuated 1 L glass flasks. The glass flasks are cylindrical and coated with a film of ZnS(Ag). 222 Rn was measured by counting the alpha particles emitted by 222 Rn and its daughter products, 218 Po and 214 Bi, when they reached radioactive equilibrium. Measurements of 222 Rn gas concentrations in the soil air interstices by the method at different depths were used to calculate the diffusion coefficient of the 222 Rn in the soil air. This study has been carried out for diverse soils. (Author)

  18. Performance tests for instruments measuring radon activity concentration

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Schmidt, V.

    2009-01-01

    Performance tests of electronic instruments measuring the activity concentration of 222 Rn have been carried out with respect to the standard IEC 61577-2. In total, 9 types of instrument operating with ionization chambers or electrostatic collection have been tested for the influence of different climatic and radiological factors on the measurement characteristics. It is concluded that all types of instrument, which are commercially available, are suitable for indoor radon measurements. Because of the dependence on climatic conditions, the outdoor use is partly limited.

  19. Measurement of mean radon concentrations in the Tokai districts

    International Nuclear Information System (INIS)

    Iida, Takao; Ikebe, Yukimasa; Yamanishi, Hirokuni

    1989-01-01

    This paper describes an electrostatic integrating radon monitor designed for the environmental radon monitoring and longterm measurements of mean radon concentrations in outdoor and indoor air. The position of the collecting electrode within the monitor was determined based on the calculation of the internal electric field. The radon exchange rate between the monitor and the outside air through the filter was 0.75 h -1 . The exchange rate can make the radon concentration inside the monitor to follow thoroughly the outside concentration. Since the electrostatic collection of RaA + ( 218 Po + ) atoms depends on the humidity of the air, the inside of the monitor was dehumidified with a diphosphorus pentaoxide (P 2 O 5 ) drying agent which is powerful and dose not absorb radon gas. From the relationship between track density and radon exposure, the calibration factor was derived to be 0.52 ± 0.002 tracks cm -2 (Bq m -3 h) -1 . The detection limit of mean radon level is 1.2 Bq m -3 for an exposure time fo 2 months. The mean radon concentrations in various environments were measured through the year using the monitors this developed. The annual mean outdoor radon level in the Tokai districts was 7.0 Bq m -3 . The mean radon concentrations was found to vary from 3.5 to 11.7 Bq m -3 depending upon the geographical conditions even in this relatively small region. The annual indoor radon concentrations at Nagoya and Sapporo ranged from 6.4 to 11.9 Bq m -3 and from 15.5 to 121.1 Bq m -3 , respectively, with the type of building material and the ventilation rate. The mean radon concentrations in tightly built houses selected at Sapporo are about 10 times as high as those in drafty houses at Nagoya. (author)

  20. Radon concentration measurements in waters in Greece and Cyprus

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Tzortzi, A.; Thanassas, D.; Serefoglou, A.; Georgiou, E.; Vogiannis, E.; Koukouliou, V.

    2004-01-01

    A total of 35 measurements in Greece and 15 in Cyprus were performed. Radon concentrations in drinking water in Greece were from (1.1±0.5) to (410±50) Bq/L. The corresponding concentrations in underground potable waters in Cyprus ranged between (0.4±0.3) Bq/L and (15±4) Bq/L. High concentrations, viz. (120±20), (320±40) and (410±50) Bq/L, were observed in three samples collected from the city of Arnea Chalkidekis in northern Greece. One water sample from Lesvos Island (north-eastern part of Greece) exhibited a radon concentration of (140±20) Bq/L. Six samples of hot spring water from the city of Loutraki (Attica prefecture), characterized as 'medicinal drinking water', contained concentrations of radon between (220±10) and (340±20) Bq/L. Radon concentrations in potable and non-potable underground water in Greece and Cyprus ranged between (0.4±0.3) and (15±4) Bq/L, whereas in surface water the range was from (2.7±0.8) to (24±6) Bq/L. (P.A.)

  1. Measurements of radon concentrations at caves in Jeju

    Energy Technology Data Exchange (ETDEWEB)

    Go, S. H.; Kang, D. H.; Jung, B. J. [Cheju National University, Cheju (Korea, Republic of)

    2004-07-01

    Radon is a radioactive gas emitting {alpha} particles. It is chemically stable due to its inert characteristic. While its daughter products, {sup 218}Po, {sup 214}Bi, {sup 214}Pb and {sup 214}Po, attached with aerosol particles, is known to cause lung cancer. As radon is produced from uranium and thorium, it accumulates in poorly ventilative underground voids such as caves and mine. Radon concentrations at caves in Jeju were measured in this study. The measurements were made by setting three CR-39 detectors for 70 days at 2 {approx} 4 positions in Manjang, Hyupjae and Ssangyong caves. The radon levels of the caves spread 403.1 . 606.7 Bq/m{sup 3}. With these results, it is concluded that the Jeju caves have 6 times higher radon concentrations than ordinary house of 65.3 Bq/m{sup 3} and that they are higher than Seoul subway stations due to poor ventilation. While, the caves in Jeju have lower radon concentrations than limestone caves of Robin Hood. The radon concentration in the middle of Manjang cave is slightly higher than the action level in the work place of 500 Bq/m{sup 3} suggested by the ICRP. The measurement errors are estimated to be less than 5 % from its calibration factor.

  2. Measurements of radon concentrations at caves in Jeju

    International Nuclear Information System (INIS)

    Go, S. H.; Kang, D. H.; Jung, B. J.

    2004-01-01

    Radon is a radioactive gas emitting α particles. It is chemically stable due to its inert characteristic. While its daughter products, 218 Po, 214 Bi, 214 Pb and 214 Po, attached with aerosol particles, is known to cause lung cancer. As radon is produced from uranium and thorium, it accumulates in poorly ventilative underground voids such as caves and mine. Radon concentrations at caves in Jeju were measured in this study. The measurements were made by setting three CR-39 detectors for 70 days at 2 ∼ 4 positions in Manjang, Hyupjae and Ssangyong caves. The radon levels of the caves spread 403.1 . 606.7 Bq/m 3 . With these results, it is concluded that the Jeju caves have 6 times higher radon concentrations than ordinary house of 65.3 Bq/m 3 and that they are higher than Seoul subway stations due to poor ventilation. While, the caves in Jeju have lower radon concentrations than limestone caves of Robin Hood. The radon concentration in the middle of Manjang cave is slightly higher than the action level in the work place of 500 Bq/m 3 suggested by the ICRP. The measurement errors are estimated to be less than 5 % from its calibration factor

  3. Alkaloid concentration of the invasive plant species Ulex europaeus in relation to geographic origin and herbivory

    Science.gov (United States)

    Hornoy, Benjamin; Atlan, Anne; Tarayre, Michèle; Dugravot, Sébastien; Wink, Michael

    2012-11-01

    In the study of plant defense evolution, invasive plant species can be very insightful because they are often introduced without their enemies, and traits linked to defense can be released from selective pressures and evolve. Further, studying plant defense evolution in invasive species is important for biological control and use of these species. In this study, we investigated the evolution of the defensive chemicals quinolizidine alkaloids (QAs) in the invasive species gorse, Ulex europaeus. Using a common garden experiment, our goals were to characterize the role of QAs relative to specialist enemies of gorse and to investigate if QA concentration evolved in invaded regions, where gorse was introduced without these enemies. Our results showed that pod infestation rate by the seed predator Exapion ulicis and infestation by the rust pathogen Uromyces genistae-tinctoriae were negatively correlated to concentration of the QA lupanine. Quinolizidine alkaloid concentration was very variable between individuals, both within and among populations, but it was not different between native and invaded regions, suggesting that no evolution of decreased resistance occurred after gorse lost its enemies. Our study also suggests that QA concentrations are traits integrated into seed predation avoidance strategies of gorse, with plants that mass-fruit in spring but do not escape pod infestation in time being richer in QAs.

  4. Petroleum hydrocarbon concentration in selected species of fish and prawn form northwest coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Mehta, P.; Kadam, A.N.; Gajbhiye, S.N.; Desai, B.N.

    of the method was in he range of 36.9-78.5% for 1-10 mu g.g/1, wet wt chrysene concentrations. The levels observed were low ranging from 0.2 to 10.0 mu g.g/1 (wet wt, chrysene equivalent units). The most abundant species Johnius glaucus and Coilia dussumieri...

  5. Measurement of the concentration of radon in the air

    International Nuclear Information System (INIS)

    Aten, J.B.Th.; Bierhuizen, H.W.J.; Hoek, L.P. van; Ros, D.; Weber, J.

    1975-01-01

    A simple transportable air monitoring apparatus was developed for controlling the radon contamination of air in laboratory rooms. It is not highly accurate but is sufficient to register the order of magnitude of the radon concentration. Air is pumped through a filter for one or two hours and an alpha decay curve of the dust on the filter is determined. Scintillation counting forty minutes after sampling indicates the radon activity. The calibration method of measuring the equilibrium of daughter product concentrations is discussed extensively

  6. Measurement of Alpha Emitters Concentration in Imported Cigarettes

    International Nuclear Information System (INIS)

    Nasser Allah, Z.K.; Musa, W.A.; AL-Rawi, A.A.S.

    2011-01-01

    The aime of this study was to measured the alpha emitters concentration of (15) different kinds of imported cigarettes. the nuclear reaction used U-235(n, f) obtained by the bombardment of U-235 with thermal neutrons from (Am B e)neutron source with thermal flux of(5*10 3 n.cm -2 .s -1 ). The Results obtained showed the values of the Uranium concentration, and varies from (0.041 ppm) in five stares kind to (2.374ppm) in Machbeth (chocolate) 100's kind. All the result obtained are within the limit levels as given by UNSCAR data

  7. Monitoring and measurement of oxygen concentrations in liquid sodium

    International Nuclear Information System (INIS)

    Smith, D.L.

    1976-01-01

    The measurement of oxygen concentrations in sodium at levels of interest for LMFBR applications is reviewed. Additional data are presented to support the validity of the vanadium-equilibration method as a reference for determination of oxygen concentrations in sodium at levels equal to or less than 15 ppM. Operating experience with electrochemical oxygen meters that have a thoria-yttria electrolyte and a Na--Na 2 O reference electrode is described. Meter lifetimes in excess of one year have generally been achieved for operating temperatures of 352 and 402 0 C, and fairly stable emfs have been observed for periods of several months. 7 fig, 21 references

  8. Measurement of radon concentration in air employing Lucas chamber

    International Nuclear Information System (INIS)

    Machaj, B.

    1997-01-01

    The results of investigations aimed to determine the main features of radon concentration gauge in air, employing 0.17 L Lucas chamber, and air sample forced by an air pump are presented. For two hour sampling and measuring cycle time the dynamic error in the worst case (first read out) equals 5 % relative to the step jump of radon concentration. This is due to the increase of activity of the decay products in the chamber. It was observed that the short lived radon decay products (Po-218, Pb-214, Bi-214) are depositing on the walls of the chamber and they are not removed by flushing the chamber with air. (author)

  9. Quantitative monitoring of microbial species during bioleaching of a copper concentrate

    Directory of Open Access Journals (Sweden)

    Sabrina Hedrich

    2016-12-01

    Full Text Available Monitoring of the microbial community in bioleaching processes is essential in order to control process parameters and enhance the leaching efficiency. Suitable methods are, however, limited as they are usually not adapted to bioleaching samples and often no taxon-specific assays are available in the literature for these types of consortia. Therefore, our study focused on the development of novel quantitative real-time PCR (qPCR assays for the quantification of Acidithiobacillus caldus, Leptospirillum ferriphilum, Sulfobacillus thermosulfidooxidans and Sulfobacillus benefaciens and comparison of the results with data from other common molecular monitoring methods in order to evaluate their accuracy and specificity. Stirred tank bioreactors for the leaching of copper concentrate, housing a consortium of acidophilic, moderately-thermophilic bacteria, relevant in several bioleaching operations, served as a model system. The microbial community analysis via qPCR allowed a precise monitoring of the evolution of total biomass as well as abundance of specific species. Data achieved by the standard fingerprinting methods, terminal restriction fragment length polymorphism (T-RFLP and capillary electrophoresis single strand conformation polymorphism (CE-SSCP on the same samples followed the same trend as qPCR data. The main added value of qPCR was, however, to provide quantitative data for each species whereas only relative abundance could be deduced from T-RFLP and CE-SSCP profiles. Additional value was obtained by applying two further quantitative methods which do not require nucleic acid extraction, total cell counting after SYBR Green staining and metal sulfide oxidation activity measurements via microcalorimetry. Overall, these complementary methods allow for an efficient quantitative microbial community monitoring in various bioleaching operations.

  10. Quantitative Monitoring of Microbial Species during Bioleaching of a Copper Concentrate.

    Science.gov (United States)

    Hedrich, Sabrina; Guézennec, Anne-Gwenaëlle; Charron, Mickaël; Schippers, Axel; Joulian, Catherine

    2016-01-01

    Monitoring of the microbial community in bioleaching processes is essential in order to control process parameters and enhance the leaching efficiency. Suitable methods are, however, limited as they are usually not adapted to bioleaching samples and often no taxon-specific assays are available in the literature for these types of consortia. Therefore, our study focused on the development of novel quantitative real-time PCR (qPCR) assays for the quantification of Acidithiobacillus caldus, Leptospirillum ferriphilum, Sulfobacillus thermosulfidooxidans , and Sulfobacillus benefaciens and comparison of the results with data from other common molecular monitoring methods in order to evaluate their accuracy and specificity. Stirred tank bioreactors for the leaching of copper concentrate, housing a consortium of acidophilic, moderately thermophilic bacteria, relevant in several bioleaching operations, served as a model system. The microbial community analysis via qPCR allowed a precise monitoring of the evolution of total biomass as well as abundance of specific species. Data achieved by the standard fingerprinting methods, terminal restriction fragment length polymorphism (T-RFLP) and capillary electrophoresis single strand conformation polymorphism (CE-SSCP) on the same samples followed the same trend as qPCR data. The main added value of qPCR was, however, to provide quantitative data for each species whereas only relative abundance could be deduced from T-RFLP and CE-SSCP profiles. Additional value was obtained by applying two further quantitative methods which do not require nucleic acid extraction, total cell counting after SYBR Green staining and metal sulfide oxidation activity measurements via microcalorimetry. Overall, these complementary methods allow for an efficient quantitative microbial community monitoring in various bioleaching operations.

  11. Fluid simulation of species concentrations in capacitively coupled N2/Ar plasmas: Effect of gas proportion

    Science.gov (United States)

    Liang, Ying-Shuang; Liu, Gang-Hu; Xue, Chan; Liu, Yong-Xin; Wang, You-Nian

    2017-05-01

    A two-dimensional self-consistent fluid model and the experimental diagnostic are employed to investigate the dependencies of species concentrations on the gas proportion in the capacitive N2/Ar discharges operated at 60 MHz, 50 Pa, and 140 W. The results indicate that the N2/Ar proportion has a considerable impact on the species densities. As the N2 fraction increases, the electron density, as well as the Ar+ and Arm densities, decreases remarkably. On the contrary, the N2 + density is demonstrated to increase monotonically with the N2 fraction. Moreover, the N density is observed to increase significantly with the N2 fraction at the N2 fractions below 40%, beyond which it decreases slightly. The electrons are primarily generated via the electron impact ionization of the feed gases. The electron impact ionization of Ar essentially determines the Ar+ density. For the N2 + production, the charge transition process between the Ar+ ions and the feed gas N2 dominates at low N2 fraction, while the electron impact ionization of N2 plays the more important role at high N2 fraction. At any gas mixtures, more than 60% Arm atoms are generated through the radiative decay process from Ar(4p). The dissociation of the feed gas N2 by the excited Ar atoms and by the electrons is responsible for the N formation at low N2 fraction and high N2 fraction, respectively. To validate the simulation results, the floating double probe and the optical emission spectroscopy are employed to measure the total positive ion density and the emission intensity originating from Ar(4p) transitions, respectively. The results from the simulation show a qualitative agreement with that from the experiment, which indicates the reliable model.

  12. Method and device for measuring the smoke concentration in air

    International Nuclear Information System (INIS)

    Rennemo, B.

    1994-01-01

    The patent deals with a method and a device for measuring the smoke concentration in air. In a smoke chamber are located two electrodes, connected to a voltage source for forming a circuit in which a DC current flows. A radioactive radiation source to ionize the air molecules is located in the vicinity of the smoke chamber, so that the number of ionized air molecules which are formed is dependent upon the radiation intensity of the ion source and the concentration of smoke particles in the smoke chamber. The charging voltage will further imply that a cloud of high ion concentration is built up close to the surface of the electrodes. The ion cloud will be discharged capacitively upon a plurality of short voltages pulses applied to the electrodes to thereby result in current pulses substantially greater than the DC current flowing through the chamber. 8 figs

  13. Diagnostics of and measures against radon concentrations in a dwelling

    International Nuclear Information System (INIS)

    Berger, H.

    1994-02-01

    Results are presented of measurements in a test-dwelling in the period april 1993 - november 1993. The purpose of the measurements was to investigate the possibilities of using a blower door (a fan in a wall of the dwelling) for specifying sources of radon in the dwelling, employing the diagnostic method developed at the KVI (Nuclear Physics Accelerator Institute in Groningen, Netherlands). Special attention is paid to the measurement of two input variables for the diagnostic method: transparency of the walls of the dwelling and the strength of static sources. Also measures aimed at reducing radon concentrations in the dwelling are discussed. The main conclusions are that (a) the pressure-variation method is a valid procedure to measure the transparency of walls and floors; (b) the blower door is a suitable technique for arriving at a correct diagnosis; and (c) over-pressurizing the crawl-space is the most effective measure in reducing the radon concentration of the crawl-space. More research on air flows in the soil is recommended. 21 figs., 28 tabs., 7 refs

  14. HO2 measurements at atmospheric concentrations using a chemical ionization mass spectrometry

    Science.gov (United States)

    Albrecht, S.; Novelli, A.; Hofzumahaus, A.; Kang, S.; Baker, Y.; Mentel, T. F.; Fuchs, H.

    2017-12-01

    Correct and precise measurements of atmospheric radical species are necessary for a better understanding of the oxidative capacity of the atmosphere. Due to the reactivity of radicals, and their consequent low concentrations, direct measurements of these species are particularly challenging and have been proven in the past to be affected by interfering species. Here we present a chemical ionization source coupled to an APi-HR-TOF-MS (Aerodyne Research Inc.), which has a limit of detection for HO2 radicals well below its atmospheric concentrations ( 1 x 108 molecules cm-3). The instrument was calibrated with a well-established and characterized HO2 calibration source in use for the laser induced fluorescence instrument in the Forschungszentrum Jülich. Within the source, a well characterized amount of HO2 radicals is produced after photolysis of water by a mercury lamp. In addition, several experiments were performed in the atmosphere simulation chamber SAPHIR at the Forschungszentrum Jülich to test for potential interferences. Measurements of HO2 radicals were concurrently detected by a laser induced fluorescence instrument allowing for the comparison of measurements within the two different and independent techniques for various atmospheric conditions regarding concentrations of O3, NOx and VOCs. Results from the intercomparison together with the calibration procedure of the instrument and laboratory characterization will be presented.

  15. Photosynthetic capacity is negatively correlated with the concentration of leaf phenolic compounds across a range of different species.

    Science.gov (United States)

    Sumbele, Sally; Fotelli, Mariangela N; Nikolopoulos, Dimosthenis; Tooulakou, Georgia; Liakoura, Vally; Liakopoulos, Georgios; Bresta, Panagiota; Dotsika, Elissavet; Adams, Mark A; Karabourniotis, George

    2012-01-01

    Phenolic compounds are the most commonly studied of all secondary metabolites because of their significant protective-defensive roles and their significant concentration in plant tissues. However, there has been little study on relationships between gas exchange parameters and the concentration of leaf phenolic compounds (total phenolics (TP) and condensed tannins (CT)) across a range of species. Therefore, we addressed the question: is there any correlation between photosynthetic capacity (A(max)) and TP and CT across species from different ecosystems in different continents? A plethora of functional and structural parameters were measured in 49 plant species following different growth strategies from five sampling sites located in Greece and Australia. The relationships between several leaf traits were analysed by means of regression and principal component analysis. The results revealed a negative relationship between TP and CT and A(max) among the different plant species, growth strategies and sampling sites, irrespective of expression (with respect to mass, area or nitrogen content). Principal component analysis showed that high concentrations of TP and CT are associated with thick, dense leaves with low nitrogen. This leaf type is characterized by low growth, A(max) and transpiration rates, and is common in environments with low water and nutrient availability, high temperatures and high light intensities. Therefore, the high TP and CT in such leaves are compatible with the protective and defensive functions ascribed to them. Our results indicate a functional integration between carbon gain and the concentration of leaf phenolic compounds that reflects the trade-off between growth and defence/protection demands, depending on the growth strategy adopted by each species.

  16. Inter-species comparative analysis of components of soluble sugar concentration in fleshy fruits

    Directory of Open Access Journals (Sweden)

    Zhanwu eDai

    2016-05-01

    Full Text Available The soluble sugar concentration of fleshy fruit is a key determinant of fleshy fruit quality. It affects directly the sweetness of fresh fruits and indirectly the properties of processed products (e.g. alcohol content in wine. Despite considerable divergence among species, soluble sugar accumulation in a fruit results from the complex interplay of three main processes, namely sugar import, sugar metabolism, and water dilution. Therefore, inter-species comparison would help to identify common and/or species-specific modes of regulation in sugar accumulation. For this purpose, a process-based mathematical framework was used to compare soluble sugar accumulation in three fruits: grape, tomato and peach. Representative datasets covering the time course of sugar accumulation during fruit development were collected. They encompassed 104 combinations of species (3, genotypes (32, and growing conditions (19 years and 16 nutrient and environmental treatments. At maturity, grape showed the highest soluble sugar concentrations (16.5-26.3 g /100 g FW, followed by peach (2.2 to 20 g /100 g FW and tomato (1.4 to 5 g /100 g FW. Main processes determining soluble sugar concentration were decomposed into sugar importation, metabolism and water dilution with the process-based analysis. Different regulation modes of soluble sugar concentration were then identified, showing either import-based, dilution-based, or import and dilution dual-based. Firstly, the higher soluble sugar concentration in grape than in tomato is a result of higher sugar importation. Secondly, the higher soluble sugar concentration in grape than in peach is due to a lower water dilution. The third mode of regulation is more complicated than the first two, with differences both in sugar importation and water dilution (grape vs cherry tomato; cherry tomato vs peach; peach vs tomato. On the other hand, carbon utilization for synthesis of non-soluble sugar compounds (namely metabolism was

  17. Aerotrace. Measurement of trace species in the exhaust of aero engines

    Energy Technology Data Exchange (ETDEWEB)

    Cottington, R V [DRA, Farnborough (United Kingdom)

    1998-12-31

    There is growing evidence that trace species, both gaseous and particulate, play an important role in the chemistry of the atmosphere. Very little is currently known about the nature and concentration of these species emitted by aircraft engines. The purpose of AEROTRACE, therefore, is to make representative measurements of trace species emissions, such as particulates, hydrocarbon constituents and various nitrogen compounds, from engine combustors over the entire flight altitude range from ground level to cruise conditions. An overview of the programme and progress to date is presented. (author)

  18. Aerotrace. Measurement of trace species in the exhaust of aero engines

    Energy Technology Data Exchange (ETDEWEB)

    Cottington, R.V. [DRA, Farnborough (United Kingdom)

    1997-12-31

    There is growing evidence that trace species, both gaseous and particulate, play an important role in the chemistry of the atmosphere. Very little is currently known about the nature and concentration of these species emitted by aircraft engines. The purpose of AEROTRACE, therefore, is to make representative measurements of trace species emissions, such as particulates, hydrocarbon constituents and various nitrogen compounds, from engine combustors over the entire flight altitude range from ground level to cruise conditions. An overview of the programme and progress to date is presented. (author)

  19. Measuring Low Concentrations of Liquid Water in Soil

    Science.gov (United States)

    Buehler, Martin

    2009-01-01

    An apparatus has been developed for measuring the low concentrations of liquid water and ice in relatively dry soil samples. Designed as a prototype of instruments for measuring the liquidwater and ice contents of Lunar and Martian soils, the apparatus could also be applied similarly to terrestrial desert soils and sands. The apparatus is a special-purpose impedance spectrometer: Its design is based on the fact that the electrical behavior of a typical soil sample is well approximated by a network of resistors and capacitors in which resistances decrease and capacitances increase (and, hence, the magnitude of impedance decreases) with increasing water content.

  20. Apparatus for measuring the concentration of a gas

    International Nuclear Information System (INIS)

    Manin, Ange.

    1974-01-01

    The apparatus described for measuring the concentration of a gas in an atmosphere is of the kind which has an ionization chamber with an internal radioactive source and associated electronics enabling the ionization current crossing the chamber to be measured. It includes at least one cylindrical metal grid forming an electrode brought to a high voltage in relation to a cylindrical collection electrode fitted to the axis of the grid coated with a radioactive deposit and, around this grid, a screen acting as a protective envelope. The radioactive deposit is tritiated titanium [fr

  1. Laser metrology in fluid mechanics granulometry, temperature and concentration measurements

    CERN Document Server

    Boutier, Alain

    2013-01-01

    In fluid mechanics, non-intrusive measurements are fundamental in order to improve knowledge of the behavior and main physical phenomena of flows in order to further validate codes.The principles and characteristics of the different techniques available in laser metrology are described in detail in this book.Velocity, temperature and concentration measurements by spectroscopic techniques based on light scattered by molecules are achieved by different techniques: laser-induced fluorescence, coherent anti-Stokes Raman scattering using lasers and parametric sources, and absorption sp

  2. Measurement of indoor radon concentration by CR-39 track detector

    International Nuclear Information System (INIS)

    Yamamoto, Masayoshi; Yoneda, Shigeru; Nakanishi, Takashi.

    1990-01-01

    A convenient and cheap method for measuring indoor radon ( 222 Rn) concentration with a CR-39 track detector is described. The detector consisted of two sheets of CR-39 enclosed separately in two plastic pots : one covered by a filter (cup method) and another no covering (bare method). The bare method was used here to supplement the cup method. To compare with the result of the CR-39 detector, alpha-ray spectrometry was carried out with a Si(Au) detector in a controlled radon exposure chamber. Indoor radon concentration measured in 133 houses in several districts of Ishikawa Prefecture have been found to range from 6 Bq/m 3 to as high as 113 Bq/m 3 with a median value of 24 Bq/m 3 . The problems to measure indoor radon concentration using the CR-39 detector are also discussed with emphasis on the position of setting the detector in the room and the possible thoron contribution to the detector. (author)

  3. THE BIOMINERAL CONCENTRATIONS AND ACCUMULATION IN SOME WILD GROWING EDIBLE SPECIES OF MUSHROOMS

    Directory of Open Access Journals (Sweden)

    Carmen Cristina Elekes

    2010-01-01

    Full Text Available Many mushrooms species are known to accumulate metals to a higher level than the plants and are considered as a source of proteins, vitamins – riboflavin, biotin and thiamine, fats, carbohydrates, amino acids and minerals. The trace metals concentrations were established by Inductively Coupled Plasma - Atomic Emission Spectrometry method. The aim of this paper is to determinate the minerals content of some wild growing mushrooms, which may be useful in the phytopharmaceutical biotechnologies in order to obtain important quantities of biominerals accessible for the human body. The results are varying with the analyzed species of mushrooms between 11869.85 and 32088.68 mg/kg for potassium, 240.81 to 716.98 mg/kg for calcium and between 0 to 5350 mg/kg for phosphorus. The highest concentration if potassium was founded in B. griseus species, 32088.68 mg/kg. Only two species, Hygrophorus virgineus and Marasmius oreades show a phosphorus concentration in the fruiting body higher than in soil, indicating the accumulation capacity.

  4. Determination of concentration and molar absorptivity of hypochlorous acid and hypobromous acid species by hydrogen peroxide titration

    Science.gov (United States)

    Uehara, H.; Arakaki, T.

    2017-12-01

    Hypochlorous acid and hypobromous acid (abbreviated as "HypoX acids") are the main ingredients of bleaching and bactericides. The HypoX acids change their chemical forms depending on environmental factors such as pH and various chemical reactions. For example, it has been reported that hypobromite ion in water changes to carcinogenic bromate by photochemical reaction with ultraviolet light. In this study, concentrations of HypoX acids were determined by UV-VIS absorbance measurement utilizing the fact that HypoX acids react with hydrogen peroxide and do not co-exist in the solution. The method for determining the concentration by titration with hydrogen peroxide can be carried out simpler and more efficiently than the DPD method or the current titration method generally used for chlorine concentration measurement. Molar absorptivity between 250 - 500 nm of HypoX acids, including their conjugate base species, was determined by solving theoretical acid-base formula including molar fraction of each chemical species at various pHs. Molar absorptivity of OCl- and OBr- between 250 - 500 nm was determined based on the concentrations obtained from titration with hydrogen peroxide and absorbance at pH > 10, where OCl- and OBr- dominate. Furthermore, the HypoX acids solutions were irradiated with a solar simulator, and the photolysis rate constants were obtained. Based on those values, the half-lives were calculated and the behavior of HypoX acids in the environment was elucidated.

  5. Birds' species diversity measurement of Uchali Wetland (Ramsar site Pakistan

    Directory of Open Access Journals (Sweden)

    Taofik Oyedele Dauda

    2017-06-01

    Full Text Available We carried out this study to evaluate bird species diversity and to model bird species abundance using Uchali Wetland, Pakistan (32°33′N, 72°01′E. Data obtained were subjected to summary statistics, Simpson diversity, Shannon evenness index, and rank abundance curve and model. The watershed supports 25,361 birds of 47 species, which is appreciably less than the number of bird species supported by the same wetland in the past year (1991. Total evenness could be obtained as the ranks increases and this differed annually. Evenness index (EI analysis showed that EI for 2011 was 0.0231, for 2012, it was 0.02, for 2013, it was 0.01, and for the annual mean, it was 0.046 indicating functional abundance of the species. Bird species diversity measurement could be enhanced by the use of the modified rank–abundance curve and would clearly present the true picture of the bird species abundance.

  6. Hypoglycin A Concentrations in Maple Tree Species in the Netherlands and the Occurrence of Atypical Myopathy in Horses.

    Science.gov (United States)

    Westermann, C M; van Leeuwen, R; van Raamsdonk, L W D; Mol, H G J

    2016-05-01

    Atypical myopathy (AM) in horses is caused by the plant toxin hypoglycin A, which in Europe typically is found in the sycamore maple tree (Acer pseudoplatanus). Owners are concerned about whether their horses are in danger if they graze near maple trees. To measure hypoglycin A in the most common maple tree species in the Netherlands, and to determine whether concentration of toxin is a predictor of AM in horses. A total of 278 samples of maple tree leaves, sprouts, and seeds were classified by species. Mean concentrations of hypoglycin A were compared for the type of sample, the season and the occurrence of AM in the pasture (non-AM versus AM). Statistical analysis was performed using generalized a linear model (SPPS22). Almost all Acer pseudoplatanus samples contained hypoglycin A, with concentrations differing significantly among sources (P < .001). Concentrations were significantly higher in seeds from the AM group than in seeds from the non-AM group (856 ± 677 and 456 ± 358 mg/kg, respectively; P = .039). In sprouts and leaves this was not the case. Acer platanoides and Acer campestre samples did not contain detectable concentrations of hypoglycin A. Acer platanoides and campestre seem to be safe around paddocks and pastures, whereas almost all Acer pseudoplatanus samples contained hypoglycin A. In all AM cases, Acer pseudoplatanus was found. Despite significantly higher concentration of hypoglycin A in seeds of pastures where AM has occurred, individual prediction of AM cannot be made by measuring these concentrations because of the high standard deviation. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. Radon concentration measurements in waters in Greece and Cyprus

    International Nuclear Information System (INIS)

    Louizi, A.; Nikolopoulos, D.; Tzortzi, A.; Thanassas, D.; Serefoglou, A.; Georgiou, E.; Vogiannis, E.; Koukouliou, V.

    2004-01-01

    The radon content of drinking water samples was determined with Alpha Guard Pro equipped with an appropriate unit (Aqua Kit). The samples were collected from water taps in dwellings located at various cities in Greece and Cyprus. In addition, surface water samples from rivers, lakes and seas as well as potable underground and hot spring water samples from Greece and Cyprus were also collected. For a precise determination of radon concentration in water samples, special procedures were followed both for sampling and transportation, as well as for measurement. Intercomparison experiments were designed and implemented before and during the study. Radon concentrations in drinking water samples in Greece ranged between 1.1 ± 0.5 Bq/L and 410±50 Bq/L. The corresponding concentrations in Cyprus ranged between 1.3 ± 0.8 Bq/L and 15±4 Bq/L. Three samples collected from the city of Arnea Chalkidikis (Northern Greece) exhibited high concentrations of 120±20 Bq/L, 320±40 Bq/L and 410±50 Bq/L. This city is identified as a high radon potential area. One water sample located in Lesvos Island (North-East part of Greece) exhibited radon concentration 140±20 Bq/L. Additional six samples displayed high concentrations in potable hot spring water samples. These samples which were collected from the city of Loutraki (Peloponnesus) ranged between 220-230 Bq/L. In addition, two samples characterized as 'medicinal drinking water' gave concentrations between 320 Bq/L and 340 Bq/L. For underground water samples the radon concentrations ranged between 1.2±0.7 Bq/L and 15±4 Bq/L, while for surface water samples the range was 2.7±0.8 Bq/L to 24±6 Bq/L. The observed concentrations of radon gas in potable water samples in Greece were found to be largely low. In Cyprus, they were all well below 15 Bq/L

  8. Measurement of plasma adenosine concentration: methodological and physiological considerations

    International Nuclear Information System (INIS)

    Gewirtz, H.; Brown, P.; Most, A.S.

    1987-01-01

    This study tested the hypothesis that measurements of plasma adenosine concentration made on samples of blood obtained in dipyridamole and EHNA (i.e., stopping solution) may be falsely elevated as a result of ongoing in vitro production and accumulation of adenosine during sample processing. Studies were performed with samples of anticoagulated blood obtained from anesthesized domestic swine. Adenosine concentration of ultra filtrated plasma was determined by HPLC. The following parameters were evaluated: (i) rate of clearance of [ 3 H]adenosine added to plasma, (ii) endogenous adenosine concentration of matched blood samples obtained in stopping solution alone, stopping solution plus EDTA, and perchloric acid (PCA), (iii) plasma and erythrocyte endogenous adenosine concentration in nonhemolyzed samples, and (iv) plasma adenosine concentration of samples hemolyzed in the presence of stopping solution alone or stopping solution plus EDTA. We observed that (i) greater than or equal to 95% of [ 3 H]adenosine added to plasma is removed from it by formed elements of the blood in less than 20 s, (ii) plasma adenosine concentration of samples obtained in stopping solution alone is generally 10-fold greater than that of matched samples obtained in stopping solution plus EDTA, (iii) deliberate mechanical hemolysis of blood samples obtained in stopping solution alone resulted in substantial augmentation of plasma adenosine levels in comparison with matched nonhemolyzed specimens--addition of EDTA to stopping solution prevented this, and (iv) adenosine content of blood samples obtained in PCA agreed closely with the sum of plasma and erythrocyte adenosine content of samples obtained in stopping solution plus EDTA

  9. Species-Specific Morphological and Physiological Responses of Four Korean Native Trees Species under Elevated CO2 Concentration using Open Top Chamber

    Science.gov (United States)

    Song, W.; Byeon, S.; Lee, H.; Lee, M.; Lim, H.; Kim, H. S.

    2017-12-01

    For the last three years, studies on the morphological and physiological characteristics were carried out for four tree species (Pinus densiflora, Quercus acutissima, Sorbus alnifolia and Fraxinus rhynchophylla) which are representative native species of Korea. We used a control site and three open top chambers (con, chamber 1, 2, and 3) which were exposed to ambient and two elevated CO2 concentration ([CO2]); the concentration were the ambient (400ppm) for control and chamber 1 and 1.4 times (560ppm) and 1.8 times (720 ppm) of the atmosphere for chamber 2 and 3, respectively. Leaf mass per area (LMA), stomatal size, density and area were examined to investigate the morphological changes of the trees. Among four species, F. rhynchophylla increased their LMA with increase of CO2 concentration. In addition, F. rhynchophylla showed the decrease of stomatal density significantly (p-value=0.02), while there was no difference in stoma size. These findings resulted in 25.5% and 38.7% decrease of stomata area per unit leaf area calculated by multiplying the size and density of the stomata. On the other hand, all 4 tree species were significantly increased in height and diameter growth with the elevated CO2. However, in the case of Q. acutissima, the increase in height growth was prominent. For physiological characteristics, the maximum photosynthetic rate was faster in the chambers exposed to high [CO2] than that in the control. However the rate of carboxylation and the electron transfer rate showed no particular tendency. The measurement of hydraulic conductivity (Ks, kg/m/s/Mpa) for Crataegus pinnatifida, increased as the [CO2] in the atmosphere increased, and the 50% Loss Conductance (Mpa) tended to increase slightly with the [CO2]. The correlation analysis between hydraulic conductivity and vulnerability to cavitation showed a strong negative correlation (P <0.05), which was unlike the general tendency.

  10. Measurement of indoor and outdoor radon concentrations during Superstorm Sandy.

    Science.gov (United States)

    Kotrappa, Payasada; Paul, Prateek; Stieff, Alex; Stieff, Frederick

    2013-12-01

    Superstorm Sandy affected much of the US East Coast extending over 1800 km. It passed over the test location in the State of Maryland on 29 October 2012. Being 350 km away from the regions of highest intensity the storm was of lower intensity at the test location. Continuous radon monitors and passive radon monitors were used for the measurement. The test location was the basement of a single family home representing the indoor concentration. A partially opened garage of the same test home represented the outdoor radon concentration. In 24 h, the atmospheric pressure dropped from 990 to 960 mbar and the indoor radon concentration increased from 70 to 1500 Bq m(-3) and returned to the normal of 70 Bq m(-3) at the end of the storm. Throughout the storm, the outdoor radon concentration was not significantly affected. Probable reasons for such surprisingly large changes are discussed. However, the outdoor temperature dropped from 13°C to 7°C during the radon peak.

  11. Integrating measurements of indoor thoron and its progeny concentrations

    International Nuclear Information System (INIS)

    Zhuo, W.H.; Iida, T.; Hashiguchi, Y.

    2000-01-01

    In recent years, indoor surveys in Europe and Asia revealed that the dose contribution from thoron and its progeny can equal or even exceed that of radon and its progeny. For measuring thoron and its progeny, several methods had been reported. However, convenient, low-cost and time-integrating measuring methods which are suitable for large-scale surveys are still unavailable. To solve this problem, three integrating measuring methods with allyl diglycol carbonate plastic (CR-39) as detectors have recently been. The results indicated that they are suitable for estimating the indoor thoron and its progeny concentrations when the public exposure to thoron and its progeny is taken into account. Cup monitor - Former types of passive integrating 222 Rn and 220 Rn cup monitors had been reported. Recently, in order to improve the sensitivity of thoron detection, the air exchange rate between the inner and outer cup was enhanced, and the radius of the hemisphere was reduced to 37.5 mm. Furthermore, the procedure of detector exchange was made to be more convenient. Equilibrium-equivalent 222 Rn and 220 Rn concentrations monitor (EEC monitor) - The measuring system is composed of a monitor head and a diaphragm pump. The total weight of the system is less than 1.5 kg, which makes it portable. The construction of the monitor head and the measuring principle were also reported by the authors. Thoron progeny deposition rate monitor - The monitor is simply constituted a piece of CR-39 covered with thin sheets of absorbers. The thickness of the absorbers are adjusted to let only the α particles emitted from 212 Pb impinge on the detector. The concentrations of thoron progeny are estimated from the deposition rates, assuming that the deposition velocities of thoron progeny are constant in general dwellings. The improved cup monitor has higher sensitivity than former monitors, with a calibration factor of 1.59x10 -3 tracks·cm -2 (Bq·m -3 ·h) -1 for thoron. The accuracy of the ECC

  12. Urinary androgen concentrations and social status in two species of free ranging zebra (Equus burchelli and E. grevyi).

    Science.gov (United States)

    Chaudhuri, M; Ginsberg, J R

    1990-01-01

    In both species of zebra, breeding males had higher urinary androgen concentrations (ng androgens/mg Cr) than did non-breeding bachelor males (30.0 +/- 5.0 (N = 9) versus 11.4 +/- 2.8, (N = 7) in the plains zebra; 19.0 +/- 2.2 (N = 17) versus 10.7 +/- 1.2 (N = 14) in the Grevy's zebra). In the more stable family structure of the plains zebra (single male non-territorial groups) variations in androgen concentrations could not be ascribed to any measured variable. In the Grevy's zebra, androgen values were significantly lower in samples taken from territorial (breeding) males which had temporarily abandoned their territories (N = 4) and the urinary androgen concentration for a male on his territory was negatively correlated with the time since females last visited the territory.

  13. Effects of forage species or concentrate finishing on animal performance, carcass and meat quality.

    Science.gov (United States)

    Duckett, S K; Neel, J P S; Lewis, R M; Fontenot, J P; Clapham, W M

    2013-03-01

    Angus-cross steers (n = 128; initial BW = 270 ± 3.8 kg) were used in a 3-yr study to assess effects of forage species grazed before slaughter versus concentrate finishing on carcass and meat quality. At the completion of the stockering phase, steers were randomly allotted to mixed pasture (MP; n = 36/yr) or corn-silage concentrate (CON; n = 12/yr) finishing treatments. At 40 d before harvest, MP steers were randomly divided into 3 forage species treatments: alfalfa (AL), pearl millet (PM), or mixed pasture (MP). Average daily BW gain was greater (P = 0.001) for CON than for forage-finished (FOR) steers during the early and overall finishing phase. During the late finishing phase when FOR steers were grazing difference forage species, ADG was greater (P = 0.03) for PM than MP or AL. Harvest weight and HCW were greater (P animal performance. Total fat percentage of the 9th to 11th rib section was 46% less(P = 0.028) for FOR than CON due to reductions (P 0.78) between CON and FOR and were not altered (P > 0.40) by forage species. Trained sensory panel juiciness, initial tenderness, and overall tenderness scores did not differ (P > 0.17) by finishing treatment or forage species. Beef flavor intensity was greater (P 0.05) total lipid content of the LM. Oleic acid concentration and total MUFA of the LM were 21% and 22% less (P = 0.001) for FOR than CON. Concentrations of all individual [linolenic acid, eicosapentaenoic (EPA), docosapentaenoic (DPA), and docosadexaenoic (DHA) acids] and total n-3 fatty acids were greater (P carcass weight with same time endpoints and accelerates deposition of MUFA in comparison with FOR, which reduces carcass weight and fat deposition but maintains high concentrations of n-3 and CLA fatty acids. Finishing system or forage species grazed 40 d before slaughter did not alter beef tenderness but FOR had greater off-flavors according to both trained and descriptive sensory panelists.

  14. Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood

    Science.gov (United States)

    Witt, K.; Wolf, H. U.; Heuck, C.; Kammel, M.; Kummrow, A.; Neukammer, J.

    2013-10-01

    Haemoglobin concentration in blood is one of the most frequently measured analytes in laboratory medicine. Reference and routine methods for the determination of the haemoglobin concentration in blood are based on the conversion of haeme, haemoglobin and haemiglobin species into uniform end products. The total haemoglobin concentration in blood is measured using the absorbance of the reaction products. Traceable absorbance measurement values on the highest metrological level are a prerequisite for the calibration and evaluation of procedures with respect to their suitability for routine measurements and their potential as reference measurement procedures. For this purpose, we describe a procedure to establish traceability of spectral absorbance measurements for the haemiglobincyanide (HiCN) method and for the alkaline haematin detergent (AHD) method. The latter is characterized by a higher stability of the reaction product. In addition, the toxic hazard of cyanide, which binds to the iron ion of the haem group and thus inhibits the oxygen transport, is avoided. Traceability is established at different wavelengths by applying total least-squares analysis to derive the conventional quantity values for the absorbance from the measured values. Extrapolation and interpolation are applied to get access to the spectral regions required to characterize the Q-absorption bands of the HiCN and AHD methods, respectively. For absorbance values between 0.3 and 1.8, the contributions of absorbance measurements to the total expanded uncertainties (95% level of confidence) of absorbance measurements range from 1% to 0.4%.

  15. Essential and non-essential element concentrations in two sleeper shark species collected in arctic waters

    Energy Technology Data Exchange (ETDEWEB)

    McMeans, Bailey C. [Great Lakes Institute for Environmental Research, University of Windsor, 401 Sunset Avenue, Windsor, ON, N9B 3P4 (Canada); Borga, Katrine [Norwegian Institute for Water Research, P.O. Box 173, Kjelsas, N-0411 Oslo (Norway); Bechtol, William R. [Alaska Department of Fish and Game, Division of Commercial Fisheries, Anchorage, AK 99518-1599 (United States); Higginbotham, David [Warnell School of Forestry and Natural Resources, University of Georgia, Athens, GA 30602-2152 (United States); Fisk, Aaron T. [Great Lakes Institute for Environmental Research, University of Windsor, 401 Sunset Avenue, Windsor, ON, N9B 3P4 (Canada)]. E-mail: afisk@uwindsor.ca

    2007-07-15

    A number of elements/metals have increased in arctic biota and are of concern due to their potential toxicity. Most studies on elements in the Arctic have focused on marine mammals and seabirds, but concentrations in the Greenland shark (Somniosus microcephalus) and Pacific sleeper shark (Somniosus pacificus), the only two shark species known to regularly inhabit arctic waters, have never been reported. To address this data gap, concentrations and patterns of 25 elements were analyzed in liver of Greenland sharks collected about Cumberland Sound (n = 24) and Pacific sleeper sharks collected about Prince William Sound (n = 14). Several non-essential elements differed between species/locations, which could suggest geographical exposure differences or ecological (e.g., diet) differences between the species. Certain essential elements also differed between the two sleeper sharks, which may indicate different physiological requirements between these closely related shark species, although information on such relationships are lacking for sharks and fish. - Patterns of essential and non-essential elements provide insight into sleeper shark biology and physiology.

  16. Essential and non-essential element concentrations in two sleeper shark species collected in arctic waters

    International Nuclear Information System (INIS)

    McMeans, Bailey C.; Borga, Katrine; Bechtol, William R.; Higginbotham, David; Fisk, Aaron T.

    2007-01-01

    A number of elements/metals have increased in arctic biota and are of concern due to their potential toxicity. Most studies on elements in the Arctic have focused on marine mammals and seabirds, but concentrations in the Greenland shark (Somniosus microcephalus) and Pacific sleeper shark (Somniosus pacificus), the only two shark species known to regularly inhabit arctic waters, have never been reported. To address this data gap, concentrations and patterns of 25 elements were analyzed in liver of Greenland sharks collected about Cumberland Sound (n = 24) and Pacific sleeper sharks collected about Prince William Sound (n = 14). Several non-essential elements differed between species/locations, which could suggest geographical exposure differences or ecological (e.g., diet) differences between the species. Certain essential elements also differed between the two sleeper sharks, which may indicate different physiological requirements between these closely related shark species, although information on such relationships are lacking for sharks and fish. - Patterns of essential and non-essential elements provide insight into sleeper shark biology and physiology

  17. Measurements of serum-free thyroid hormone concentrations by ultrafiltration

    International Nuclear Information System (INIS)

    Konno, Norimichi; Hagiwara, Kohji; Taguchi, Hideo; Murakami, Shigeki; Taguchi, Shizuko

    1987-01-01

    An ultrafiltration method (UF) for measuring free thyroxine (FT 4 ) and free triiodothyronine (FT 3 ) using the Diaflow YM membrane (Centricon-10) is described. The results are compared with those by equilibrium dialysis (ED) and also by mathematical calculations derived from T 4 , T 3 , and binding protein concentrations. The precision with the UF method was excellent. The normal ranges of FT 4 and FT 3 by the three methods are all comparable. There was a high degree of correlation of FT 4 or FT 3 results by UF with those by ED and by calculation (r = 0.940 - 0.974, n = 161, P 4 and FT 3 by all methods agreed well for hyperthyroidism, hypothyroidism, and for patients with low T 4 -binding globulin. The mean FT 3 in pregnancy was lower than the normal value for all methods, and FT 4 concentrations by UF and calculation also decreased in late pregnancy. The mean FT 4 by UF and ED in low T 3 syndrome were significantly higher than in the normal controls, while the calculated FT 4 was lower. The FT 3 in low T 3 syndrome distributed normal to subnormal in all methods. These results indicate that a) the UF method is a reliable reference method for measuring FT 4 and FT 3 concentrations; b) the UF results agree well with those by ED and also with theoretically derived values in subjects with thyroid diseases and TBG abnormalities; c) for patients with low T 3 syndrome, the FT 4 results obtained by UF and ED are similarly discrepant from the calculated results, implying the existence of binding inhibitor(s) which affect both UF and ED measurements. (author)

  18. Relaxin concentrations in serum and urine of endangered and crazy mixed-up species.

    Science.gov (United States)

    Steinetz, B; Lasano, S; de Haas van Dorsser, F; Glickman, S; Bergfelt, D; Santymire, R; Songsassen, N; Swanson, W

    2009-04-01

    The human population explosion has pushed many mammalian wildlife species to the brink of extinction. Conservationists are increasingly turning to captive breeding as a means of preserving the gene pool. We previously reported that serum immunoactive relaxin provided a reliable means of distinguishing between true and pseudopregnancy in domestic dogs, and this method has since been found to be a reliable indicator of true pregnancy in endangered Asian and African elephants and Sumatran rhinoceroses. Our canine relaxin radioimmunoassay (RIA) has now been adapted and validated to measure relaxin in the serum and urine of felids, including domestic and wild species. Moreover, a commercially available canine serum relaxin kit (Witness) Relaxin Kit; Synbiotics, San Diego, CA), has been adapted for reliable detection of relaxin in urine of some felid species. Our porcine relaxin RIA has also been utilized to investigate the role of relaxin in reproductive processes of the spotted hyena, a species in which the female fetuses are severely masculinized in utero. Indeed, this species might well now be extinct were it not for the timely secretion of relaxin to enable copulation and birth of young through the clitoris. Additional studies have suggested relaxin may be a useful marker of pregnancy in the northern fur seal and the maned wolf (the former species has been designated as "depleted" and the latter as "near threatened"). Given appropriate immunoassay reagents, relaxin determination in body fluids thus provides a powerful tool for conservationists and biologists investigating reproduction in a wide variety of endangered and exotic species.

  19. Artifacts in measuring aerosol uptake kinetics: the roles of time, concentration and adsorption

    Directory of Open Access Journals (Sweden)

    L. H. Renbaum

    2011-07-01

    Full Text Available In laboratory studies of organic aerosol particles reacting with gas-phase oxidants, high concentrations of radicals are often used to study on the timescale of seconds reactions which may be occurring over days or weeks in the troposphere. Implicit in this approach is the assumption that radical concentration and time are interchangeable parameters, though this has not been established. Here, the kinetics of OH- and Cl-initiated oxidation reactions of model single-component liquid (squalane and supercooled (brassidic acid and 2-octyldodecanoic acid organic aerosols are studied by varying separately the radical concentration and the reaction time. Two separate flow tubes with residence times of 2 and 66 s are used, and [OH] and [Cl] are varied by adjusting either the laser photolysis fluence or the radical precursor concentration ([O3] or [Cl2], respectively used to generate the radicals. It is found that the rates measured by varying the radical concentration and the reaction time are equal only if the precursor concentrations are the same in the two approaches. Further, the rates depend on the concentrations of the precursor species with a Langmuir-type functional form suggesting that O3 and Cl2 saturate the surface of the liquid particles. It is believed that the presence of O3 inhibits the rate of OH reaction, perhaps by reacting with OH radicals or by O3 or intermediate species blocking surface sites, while Cl2 enhances the rate of Cl reaction by participating in a radical chain mechanism. These results have important implications for laboratory experiments in which high concentrations of gas-phase oxidants are used to study atmospheric reactions over short timescales and may explain the variability in recent measurements of the reactive uptake of OH on squalane particles in reactor systems used in this and other laboratories.

  20. assessment of Seawater Intrusion in Concrete by Measuring Chlorine Concentration

    International Nuclear Information System (INIS)

    Abdel-Monem, A.M.; Kansouh, W.A.; Osman, A.M.; Bashter, I.I.

    2011-01-01

    The object of this work is to measure water intrusion in concrete using a new methodology based on neutron activation technique. The applied method depends on measuring the activated gamma energy lines emitted from 38 Cl using a gamma spectrometer with Ge(Li) and HPGe detectors. Concrete samples with different percentages of silica fume (SF), up to 20 % submerged in seawater for different period of time were used to perform the investigation. Samples of concrete taken from different positions along the direction of water intrusion in concrete block were irradiated by thermal neutrons using the irradiation cell of 252 Cf neutron source and one of the vertical channels of search reactor at Delft University. The measured 38 Cl concentrations of the irradiated samples were used to plot groups of water profiles distribution in concrete samples with different SF % and submerged in seawater for different periods. These profiles were compared with the others which use here measured by neutron back emitted method where a satisfactory agreement was observed between the two. Further, the displayed measured results; show that the diffusivity for all water contents decreases with increasing the silica fume percentage up to 15 %. However, for concrete samples with silica fume 20 % the observed phenomenon is reversed due to the deterioration of concrete physical and mechanical properties

  1. Si-Traceable Scale for Measurements of Radiocarbon Concentration

    Science.gov (United States)

    Hodges, Joseph T.; Fleisher, Adam J.; Liu, Qingnan; Long, David A.

    2017-06-01

    Radiocarbon (^{14}C) dating of organic materials is based on measuring the ^{14}C/^{12}C atomic fraction relative to the nascent value that existed when the material was formed by photosynthetic conversion of carbon dioxide present in the atmosphere. This field of measurement has numerous applications including source apportionment of anthropogenic and biogenic fuels and combustion emissions, carbon cycle dynamics, archaeology, and forensics. Accelerator mass spectrometry (AMS) is the most widely used method for radiocarbon detection because it can measure extremely small amounts of radiocarbon (background of nominally 1.2 parts-per-trillion) with high relative precision (0.4 %). AMS measurements of radiocarbon are typically calibrated by reference to standard oxalic-acid (C_2H_2O_4) samples of known radiocativity that are derived from plant matter. Specifically, the internationally accepted absolute dating reference for so-called "modern-equivalent" radiocarbon is 95 % of the specific radioactivity in AD 1950 of the National Bureau of Standards (NBS) oxalic acid standard reference material and normalized to δ^{13}C_{VPDB} = 19 per mil. With this definition, a "modern-equivalent" corresponds to 1.176(70) parts-per-trillion of ^{14}C relative to total carbon content. As an alternative radiocarbon scale, we propose an SI-traceable method to determine ^{14}C absolute concentration which is based on linear Beer-Lambert-law absorption measurements of selected ^{14}C^{16}O_2 ν_3-band line areas. This approach is attractive because line intensities of chosen radiocarbon dioxide transitions can be determined by ab initio calculations with relative uncertainties below 0.5 %. This assumption is justified by the excellent agreement between theoretical values of line intensities and measurements for stable isotopologues of CO_2. In the case of cavity ring-down spectroscopy (CRDS) measurements of ^{14}C^{16}O_2 peak areas, we show that absolute, SI-traceable concentrations of

  2. Measurements of thoron and radon progeny concentrations in Beijing, China

    International Nuclear Information System (INIS)

    Zhang Lei; Liu Cuihong; Guo Qiuju

    2008-01-01

    It has been reported that thoron levels in China are above the world average and may therefore make a significant contribution to the natural background radiation dose. We therefore conducted a pilot study of concentrations of both thoron and radon progeny during the spring of 2006 in the Beijing area, China. A new type of portable 24 h integrating monitor with a CR-39 detector was used during the survey. Seventy dwellings and eight outdoor sites were measured during the survey. For country houses built of red bricks and slurry, the average equilibrium equivalent concentrations (EEC) of thoron and radon were 1.02 ± 0.48 and 16.41 ± 9.02 Bq m -3 , respectively, whereas for city dwellings built of cement blocks and floor slabs, the results were 0.48 ± 0.47 and 11.50 ± 6.99 Bq m -3 for thoron and radon, respectively. For outdoor air, concentrations of thoron and radon progeny were 0.29 ± 0.28 and 7.05 ± 2.68 Bq m -3 , respectively. Radiation exposures from thoron and radon progeny were also evaluated; the ratio of dose contribution from thoron progeny to that of radon progeny was evaluated to be 28% and 17% in country houses and city dwellings, respectively. (note)

  3. Measurements of indoor 222Rn concentration in two art galleries

    International Nuclear Information System (INIS)

    Carneiro, Luana Gomes; Braz, Delson; Jesus, Edgar Francisco de; Cunha, Kenya Dias da; Medeiros, Geiza; Zouain, Felipe; Pitassi, Gabriel; Leite, Carlos Barros; Cardoso, Katia

    2009-01-01

    It is point out that radon and their decay products in environment give high dose to human lung. Studies indicate that the indoor radon inhalation by humans has been considered probably the second most important cause of lung cancer after of smoking. A passive-type radon detector was used for measuring indoor radon concentration in two art galleries at Rio de Janeiro city during 90 days January to March, 2009. The aim of this study is to evaluate the occupational and public radon exposure in art galleries and museums. This paper shows the preliminary results of samples collected at two art galleries located in Gavea, Rio de Janeiro city. 30 LEXAN (GE) track detectors were exposed in the air (indoor as well as outdoor). The samples were collected in the same building which is a construction of XIX century. The analysis of the results suggests that the 222 Rn concentration levels are different in both sampling site, in closed environmental, demonstrating that, although the construction materials are the same the absence of circulating air is a factor very important to increase the concentration of indoor Rn. (author)

  4. The Dynamics of Glutathione Species and Ophthalmate Concentrations in Plasma from the VX2 Rabbit Model of Secondary Liver Tumors

    Directory of Open Access Journals (Sweden)

    R. Abbas

    2011-01-01

    Full Text Available Purpose. Available tumor markers have low sensitivity/specificity for the diagnosis of liver tumors. The present study was designed to evaluate the oxidoreductive status of the liver as surrogates of tumor subsistence and growth. Methods. Glutathione species (GSH:GSSG, ophthalmate (OA concentrations, and their turnover were measured in plasma of rabbits (n=6 in their healthy state and in the state of tumor growth after implantation of the VX2 carcinoma in their liver. Tumors were allowed to grow for a period of 14 days when rabbits were sacrificed. Livers were removed and cysteine concentration was measured in liver tissue. Results. Tumor growth was found in 100% of the rabbits. Concentration and labeling of GSH/GSSG were similar in experimental animals before and after tumor implantation and to sham animals. In contrast, OA concentration increased significantly in experimental animals after tumor implantation when compared to same animals prior to tumor implantation and to sham animals (P<.05. The concentration of cysteine, a precursor of GSH, was found to be significantly lower in the liver tissue adjacent to the tumor (P<.05. Conclusion. Disturbances in the oxidoreductive state of livers appear to be a surrogate of early tumor growth.

  5. Incorporation monitoring by measurements of activity concentrations in air

    International Nuclear Information System (INIS)

    Breukelmann, G.; Dalheimer, A.; Dilger, H.; Henrichs, K.

    1997-01-01

    The incorporation monitoring of workers handling actinides is in many cases not possible by individual methods: The sensitivity of bioassay of methods (in vivo, in vitro) is not sufficient to detect amounts as required by the low annual limits of intake. Similar difficulties may occur with the use of radionuclides with very short physical half-lives. In these cases, the measuring of activity concentrations in the air is the only way to monitor the workers and to meet legal requirements. The essential problem connected with this approach is to make sure, that the air sample analyzed represents the average air inhaled actually. Correspondingly, the new system regulating the incorporation monitoring in Germany requires additional measures to ensure this representatively. (author)

  6. Measurement limits to 134Cs concentration in soil

    International Nuclear Information System (INIS)

    Ahn, J.K.; Kim, J.S.; Lee, H.M.; Kim, H.; Kim, T.H.; Park, J.N.; Kang, Y.S.; Lee, H.S.; Kim, S.J.; Park, J.Y.; Ryu, S.Y.; Kim, H.-Ch.; Kang, W.G.; Kim, S.K.

    2011-01-01

    We investigate the caesium concentrations in soils in mountain areas near Gori nuclear power plant in Korea, focusing on the measurement limits to the 134 Cs. In order to lower the minimum detectable amount (MDA) of activity for the 134 Cs, we have used the ammonium molybdophosphate (AMP) precipitation method to get rid of the 40 K existing in natural radioactivity, which reduces the MDA activity about 10 times smaller than those without the AMP precipitation method. The MDA results for the 134 Cs were found to be in the range between 0.015 and 0.044 Bq/kg-dry weight. In order to diminish the background, we also have measured a part of the soil samples in Yangyang, a small town in the east coast of Korea. However, it turns out that in order to detect the 134 Cs in the samples the MDA should be reduced to the level of mBq/kg-dry weight. - Highlights: → We study the caesium concentrations in soils in mountain areas near Gori NPT in Korea. → We use the AMP precipitation method to lower the minimum detectable amount (MDA) of activity for the 134 Cs. → The results of the MDA for the 134 Cs turn out to be in the range between 0.015 and 0.044. → In order to detect the 134 Cs in the samples, the MDA should be reduced to the level of mBq/kg-dry weight.

  7. Measuring the energy security implications of fossil fuel resource concentration

    International Nuclear Information System (INIS)

    Lefevre, Nicolas

    2010-01-01

    Economic assessments of the welfare effects of energy insecurity are typically uncertain and fail to provide clear guidance to policy makers. As a result, governments have had little analytical support to complement expert judgment in the assessment of energy security. This is likely to be inadequate when considering multiple policy goals, and in particular the intersections between energy security and climate change mitigation policies. This paper presents an alternative approach which focuses on gauging the causes of energy insecurity as a way to assist policy making. The paper focuses on the energy security implications of fossil fuel resource concentration and distinguishes between the price and physical availability components of energy insecurity. It defines two separate indexes: the energy security price index (ESPI), based on the measure of market concentration in competitive fossil fuel markets, and the energy security physical availability index (ESPAI), based on the measure of supply flexibility in regulated markets. The paper illustrates the application of ESPI and ESPAI with two case studies-France and the United Kingdom-looking at the evolution of both indexes to 2030.

  8. Measuring the energy security implications of fossil fuel resource concentration

    Energy Technology Data Exchange (ETDEWEB)

    Lefevre, Nicolas [Woodrow Wilson School of Public and International Affairs, Princeton University, New Jersey (United States)

    2010-04-15

    Economic assessments of the welfare effects of energy insecurity are typically uncertain and fail to provide clear guidance to policy makers. As a result, governments have had little analytical support to complement expert judgment in the assessment of energy security. This is likely to be inadequate when considering multiple policy goals, and in particular the intersections between energy security and climate change mitigation policies. This paper presents an alternative approach which focuses on gauging the causes of energy insecurity as a way to assist policy making. The paper focuses on the energy security implications of fossil fuel resource concentration and distinguishes between the price and physical availability components of energy insecurity. It defines two separate indexes: the energy security price index (ESPI), based on the measure of market concentration in competitive fossil fuel markets, and the energy security physical availability index (ESPAI), based on the measure of supply flexibility in regulated markets. The paper illustrates the application of ESPI and ESPAI with two case studies - France and the United Kingdom - looking at the evolution of both indexes to 2030. (author)

  9. Radioactivity concentration measuring device for radiation waste containing vessel

    International Nuclear Information System (INIS)

    Goto, Tetsuo.

    1994-01-01

    The device of the present invention can precisely and accurately measure a radioactive concentration of radioactive wastes irrespective of the radioactivity concentration distribution. Namely, a Ge detector having a collimator and a plurality of radiation detectors are placed at the outside of the radioactive waste containing vessel in such a way that it can rotate and move vertically relative to the vessel. The plurality of radiation detectors detect radiation coefficient signals at an assumed segment unit of a predetermined length in vertical direction and for every predetermined angle unit in the rotational direction. A weight measuring device determines the weight of the vessel. A computer calculates an average density of radioactivity for the region filled with radioactivity based on the determined net weight and radiation coefficient signals assuming that the volume of the radioactivity is constant. In addition, the computer calculates the amount of radioactivity in the assumed segment by conducting γ -ray absorption compensation calculation for the material in the vessel. Each of the amount of radioactivity is integrated to determine the amount of radioactivity in the vessel. (I.S.)

  10. Tracking and shape errors measurement of concentrating heliostats

    Science.gov (United States)

    Coquand, Mathieu; Caliot, Cyril; Hénault, François

    2017-09-01

    In solar tower power plants, factors such as tracking accuracy, facets misalignment and surface shape errors of concentrating heliostats are of prime importance on the efficiency of the system. At industrial scale, one critical issue is the time and effort required to adjust the different mirrors of the faceted heliostats, which could take several months using current techniques. Thus, methods enabling quick adjustment of a field with a huge number of heliostats are essential for the rise of solar tower technology. In this communication is described a new method for heliostat characterization that makes use of four cameras located near the solar receiver and simultaneously recording images of the sun reflected by the optical surfaces. From knowledge of a measured sun profile, data processing of the acquired images allows reconstructing the slope and shape errors of the heliostats, including tracking and canting errors. The mathematical basis of this shape reconstruction process is explained comprehensively. Numerical simulations demonstrate that the measurement accuracy of this "backward-gazing method" is compliant with the requirements of solar concentrating optics. Finally, we present our first experimental results obtained at the THEMIS experimental solar tower plant in Targasonne, France.

  11. Corticosterone Concentrations Reflect Parental Expenditure in Contrasting Mating Systems of Two Coucal Species

    Directory of Open Access Journals (Sweden)

    Wolfgang Goymann

    2017-03-01

    Full Text Available The period of parental care can be a demanding life-history stage because parents need to find sufficient resources to feed themselves and their offspring. Often, this is reflected by elevated baseline levels of glucocorticoids—hormones that regulate metabolism and energy allocation. During 10 breeding seasons, we studied plasma corticosterone (the major avian glucocorticoid concentrations as a physiological correlate of parental expenditure in two closely related coucal species with fundamentally different mating systems: the sex-role reversed black coucal (Centropus grillii with female competition and male-only care and the socially monogamous and biparental white-browed coucal (C. superciliosus. The two species live in the same habitat and share a similar breeding biology. However, female black coucals aggressively defend a territory and produce many eggs for their various male partners, and male black coucals feed their offspring much more frequently and rest less often than female and male white-browed coucals. These differences were reflected in baseline and stress-induced concentrations of corticosterone: male black coucals had higher baseline and stress-induced corticosterone concentrations when they were feeding young than outside a feeding context, and also the concentrations of female black coucals were higher during the main period of breeding when they defended territories and produced multiple clutches. In contrast, baseline and stress-induced concentrations of corticosterone in female and male white-browed coucals did not differ between periods when they were feeding young and periods without dependent offspring. Paradoxically, on an individual basis feeding effort was negatively related to baseline corticosterone in male black coucals and female white-browed coucals. In conclusion, corticosterone concentrations of coucals reflected differences in competition and parental roles and support the notion that a switch from

  12. Quantitative measurement of cyanide species in simulated ferrocyanide Hanford waste

    International Nuclear Information System (INIS)

    Bryan, S.A.; Pool, K.H.; Matheson, J.D.

    1993-02-01

    Analytical methods for the quantification of cyanide species in Hanford simulated high-level radioactive waste were pursued in this work. Methods studied include infrared spectroscopy (solid state and solution), Raman spectroscopy, Moessbauer spectroscopy, X-ray diffraction, scanning electron microscopy-electron dispersive spectroscopy (SEM-EDS), and ion chromatography. Of these, infrared, Raman, X-ray diffraction, and ion chromatography techniques show promise in the concentration range of interest. Quantitation limits for these latter four techniques were demonstrated to be approximately 0.1 wt% (as cyanide) using simulated Hanford wastes

  13. Petroleum hydrocarbon concentrations in ten commercial fish species along Tamilnadu coast, Bay of Bengal, India.

    Science.gov (United States)

    Veerasingam, S; Venkatachalapathy, R; Raja, P; Sudhakar, S; Rajeswari, V; Asanulla, R Mohamed; Mohan, R; Sutharsan, P

    2011-05-01

    The aim of the present study was to evaluate the distribution of petroleum hydrocarbons in ten commercial fish species and water samples in three estuaries along Tamilnadu coast, Bay of Bengal, India. Fish and water samples collected from Tamilnadu coast, India, were extracted and analyzed for petroleum hydrocarbons by ultraviolet fluorescence (UVF) spectroscopy. The petroleum hydrocarbon concentration (PHC) in coastal waters and fish species varied between 2.28 and 14.02 μg/l and 0.52 and 2.05 μg/g, respectively. The highest PHC concentration was obtained in Uppanar estuarine waters (14.02 ± 0.83) and the lowest was observed in Vellar estuarine waters (2.28 ± 0.25). Among the ten fish species, Sardinella longiceps have high PHC concentration from all the locations. This study suggests that S. longiceps can be used as a good biological indicator for petroleum hydrocarbon pollution in water. The concentration of petroleum hydrocarbons in coastal waters along Tamilnadu coast is markedly higher than that in the background, but there is no evidence for its increase in fish of this region. From a public health point, petroleum hydrocarbon residue levels in all fish samples analyzed in this study are considerably lower than the hazardous levels. At present, as Tamilnadu coastal area is in a rapid development stage of new harbour, chemical industries, power plants, oil exploration and other large-scale industries, further assessment of petroleum hydrocarbons and the various hydrodynamic conditions acting in the region are to be studied in detail and continuous pollution monitoring studies should be conducted for improving the aquatic environment. The results will also be useful for pollution monitoring program along the coastal region and also to check the levels of petroleum hydrocarbons.

  14. Wavelength Modulation Spectroscopy for Temperature and Species Concentration in the Plume of a Supersonic Nozzle (Conference Paper with Briefing Charts)

    Science.gov (United States)

    2017-07-12

    Paper with Briefing Charts 22 May 2017 - 30 July 2017 Wavelength Modulation Spectroscopy for Temperature and Species Concentration in the Plume of a...environments. Wavelength modulation spectroscopy (WMS) is a laser absorption spectroscopy technique that allows for quantitative, time-resolved...American Institute of Aeronautics and Astronautics 1 Wavelength Modulation Spectroscopy for Temperature and Species Concentration in the

  15. Mesocosm validation of the marine No Effect Concentration of dissolved copper derived from a species sensivity distribution

    NARCIS (Netherlands)

    Foekema, E.M.; Kaag, N.H.B.M.; Kramer, K.J.M.; Long, K.

    2015-01-01

    The Predicted No Effect Concentration (PNEC) for dissolved copper based on the species sensitivity distribution (SSD) of 24 marine single species tests was validated in marine mesocosms. To achieve this, the impact of actively maintained concentrations of dissolved copper on a marine benthic and

  16. Measuring β-diversity with species abundance data.

    Science.gov (United States)

    Barwell, Louise J; Isaac, Nick J B; Kunin, William E

    2015-07-01

    Baselga R turn , βBaselga B-C turn and βsim measured purely species turnover and were independent of nestedness. Among the other metrics, sensitivity to nestedness varied >4-fold. Our results indicate large amounts of redundancy among existing β-diversity metrics, whilst the estimation of unseen shared and unshared species is lacking and should be addressed in the design of new abundance-based metrics. © 2015 The Authors. Journal of Animal Ecology published by John Wiley & Sons Ltd on behalf of British Ecological Society.

  17. Strontium and zinc concentrations in otoliths of common fish species in the northern Baltic Sea

    International Nuclear Information System (INIS)

    Lill, J.-O.; Himberg, M.; Harju, L.; Ek, P.; Lindroos, A.; Wiklund, T.; Gunnelius, K.; Smått, J.-H.; Heselius, S.-J.; Hägerstrand, H.

    2014-01-01

    Otoliths of perch (Perca fluviatilis), pike (Esox lucius) and European whitefish (Coregonus lavaretus) caught at different locations in the northern Baltic Sea along the Finnish west coast and at some rivers and lakes were subjected to elemental analyses with particle induced X-ray emission and laser ablation inductively coupled plasma mass spectrometry. The strontium concentration in otoliths from whitefish (∼3300 μg/g) was 2–3 times higher than that of perch and pike (∼1400 μg/g), while within species the strontium concentration of otoliths from fish caught at different locations was in the same range. The strontium concentrations were lowest in fish from the lakes (∼450 μg/g). Whitefish otoliths contained more zinc (∼60 μg/g) than those of pike (∼30 μg/g), while the zinc concentration in perch otoliths were below the detection limit. No spatial intraspecies variations in zinc concentrations were observed. X-ray diffraction showed that the otoliths consisted of aragonite solely

  18. Strontium and zinc concentrations in otoliths of common fish species in the northern Baltic Sea

    Energy Technology Data Exchange (ETDEWEB)

    Lill, J.-O., E-mail: jlill@abo.fi [Accelerator Laboratory, Turku PET Centre, Åbo Akademi University, Porthansgatan 3, FI-20500 Turku (Finland); Himberg, M. [Laboratory of Aquatic Pathobiology, Husö Biological Station, Environmental and Marine Biology, Department of Biosciences, Åbo Akademi University, Artillerigatan 6, FI-20520 Turku (Finland); Harju, L.; Ek, P. [Analytical Chemistry, Department of Chemical Engineering, Åbo Akademi University, Biskopsgatan 8, FI-20500 Turku (Finland); Lindroos, A. [Geology and Mineralogy, Department of Natural Sciences, Åbo Akademi University, Domkyrkotorget, FI-20500 Turku (Finland); Wiklund, T. [Laboratory of Aquatic Pathobiology, Husö Biological Station, Environmental and Marine Biology, Department of Biosciences, Åbo Akademi University, Artillerigatan 6, FI-20520 Turku (Finland); Gunnelius, K.; Smått, J.-H. [Physical Chemistry, Department of Natural Sciences, Åbo Akademi University, Porthansgatan 3, FI-20500 Turku (Finland); Heselius, S.-J. [Accelerator Laboratory, Turku PET Centre, Åbo Akademi University, Porthansgatan 3, FI-20500 Turku (Finland); Hägerstrand, H. [Laboratory of Aquatic Pathobiology, Husö Biological Station, Environmental and Marine Biology, Department of Biosciences, Åbo Akademi University, Artillerigatan 6, FI-20520 Turku (Finland)

    2014-01-01

    Otoliths of perch (Perca fluviatilis), pike (Esox lucius) and European whitefish (Coregonus lavaretus) caught at different locations in the northern Baltic Sea along the Finnish west coast and at some rivers and lakes were subjected to elemental analyses with particle induced X-ray emission and laser ablation inductively coupled plasma mass spectrometry. The strontium concentration in otoliths from whitefish (∼3300 μg/g) was 2–3 times higher than that of perch and pike (∼1400 μg/g), while within species the strontium concentration of otoliths from fish caught at different locations was in the same range. The strontium concentrations were lowest in fish from the lakes (∼450 μg/g). Whitefish otoliths contained more zinc (∼60 μg/g) than those of pike (∼30 μg/g), while the zinc concentration in perch otoliths were below the detection limit. No spatial intraspecies variations in zinc concentrations were observed. X-ray diffraction showed that the otoliths consisted of aragonite solely.

  19. Laboratory Measurements of Particulate Matter Concentrations from Asphalt Pavement Abrasion

    Directory of Open Access Journals (Sweden)

    Fullová Daša

    2016-12-01

    Full Text Available The issue of emissions from road traffic is compounded by the fact that the number of vehicles and driven kilometres increase each year. Road traffic is one of the main sources of particulate matter and traffic volume is still increasing and has unpleasant impact on longevity of the pavements and the environment. Vehicle motions cause mechanical wearing of the asphalt pavement surface - wearing course by vehicle tyres. The contribution deals with abrasion of bituminous wearing courses of pavements. The asphalt mixtures of wearing courses are compared in terms of mechanically separated particulate matter. The samples of asphalt mixtures were rutted in wheel tracking machine. The particulate matter measurements were performed in laboratory conditions. The experimental laboratory measurements make it possible to sample particulates without contamination from exhaust emissions, abraded particles from vehicles, resuspension of road dust and climate affects. The contribution offers partial results of measurements on six trial samples of asphalt mixtures with different composition. It presents particulate matter morphology and the comparison of rutted asphalt samples in terms of PM mass concentrations and chemical composition.

  20. Concentration factors for 226Ra in the mullet (Mugilidae) species Mugil cephalus from the South Adriatic Sea

    International Nuclear Information System (INIS)

    Ivanka Antovic; Antovic, N.M.

    2011-01-01

    226 Ra activity concentration in the mullet (Mugilidae) species Mugil cephalus whole individuals, and some organs (gills, gastrointestinal system, fins, muscle and bones), was measured by the γ-coincidence spectrometer PRIPYAT-2M. 226 Ra transfer parameters [concentration factors (CFs)] from seawater, sediment and mud with detritus to fish tissues, and annual intake by humans consuming this fish species, have been estimated. Minimum detected radium activity concentration in whole M. cephalus individuals was found to be 0.89 ± 0.42 to 3.09 ± 0.41 Bq kg-1, with arithmetic mean of 1.65 ± 0.39 Bq kg -1 . An average concentration in muscles is found to be 2.28 ± 0.84 Bq kg -1 , in gills - 5.02 ± 1.85 Bq kg -1 , in gastrointestinal system - 12.88 ± 1.71 Bq kg -1 , and in bones - 14.72 ± 3.75 Bq kg -1 . No one fins showed radium activity above minimum detectable one. Annual intake of 226 Ra by human consumers of this fish species is estimated to provide an effective dose of 0.006 mSv year -1 . CFs for 226 Ra indicating transfer from seawater to whole individuals ranged from 8.9 to 30.9, and those indicating transfer from the sediment and mud with detritus - from 0.11 to 0.39 and from 0.08 to 0.3, respectively. The seawater to bones CFs varied from 97.9 to 197.3, to gastrointestinal system - from 59 to 178.8, to gills - from 22.5 to 68.3, to muscles - from 17 to 30.8. (author)

  1. Measurement of interstitial cetirizine concentrations in human skin

    DEFF Research Database (Denmark)

    Petersen, Lars Jelstrup; Church, M K; Rihoux, J P

    1999-01-01

    BACKGROUND: The purpose of the present study was to measure the concentrations of cetirizine in the extracellular water compartment in intact human skin and assess simultaneously inhibition of histamine-induced wheal and flare reactions. METHODS: Skin cetirizine levels were collected...... by the microdialysis technique and analyzed by high-pressure liquid chromatography with mass spectrometry detection. Skin levels in 20 subjects were compared to plasma levels for 4 h after a single oral dose of 10 or 20 mg of cetirizine. Skin prick tests were performed with histamine 100 mg/ml. RESULTS: Plasma...... cetirizine levels increased within 30 min to reach peak values of 315+/-10 and 786+/-45 ng/ml 90-120 min after administration of 10 and 20 mg of cetirizine. This was followed by a slow decline. In the skin, dialysate cetirizine levels (non-protein-bound fraction only) peaked at 1.6+/-0.1 and 2.4+/-0.3 ng...

  2. An Alpha spectrometer for measuring radon daughter individual activity concentration

    International Nuclear Information System (INIS)

    Berico, M.; Formignani, M.; Mariotti, F.

    2001-01-01

    In the frame of the program of the Institute for Radiation Protection of ENEA, related to the evaluation of dose from radon and thoron progeny, an alpha spectrometer for the continuous air monitoring (CAM type) of radon and thoron has been realized. The constructive characteristics of the device are here presented together with energy and efficiency calibration. The device allows, by means of a screen type diffusion battery and a filter, to determinate the single radioactivity of each radionuclide of the progeny selecting them in relation to their diffusive behaviour (dichotomous particle size selection). The three-count filter method has been employed to measure the concentrations of 218 Po, 214 Pb and 214 Bi in air. Radon and thoron effective doses using a dosimetric, instead of an epidemiologic approach, will be then evaluated [it

  3. Concentrations and chemical species of arsenic in human urine and hair

    Energy Technology Data Exchange (ETDEWEB)

    Yamato, Naohisa (St. Marianna Univ. School of Medicine, Kawasaki (Japan))

    1988-05-01

    Because marine products are rich in arsenic, the concentration of arsenic in the human urine varies greatly with the state of ingestion of marine products. It has been revealed that inorganic arsenic is methylated in the human body to form MAA (methylarsonic acid) and DMAA (dimethylarsinic acid). It appears therefore that the arsenic present in the human urine is a mixture of the arsenic originating from marine products and the arsenic metabolized in vivo. Recent studies have shown that inorganic arsenic and methylarsenic compounds are quite different in toxicity and effect on the living body due to their difference in chemical species. Finding the chemical species of arsenic in the urine and hair of normal subjects will therefore provide valuable basal data for the biological monitoring of arsenic exposure and for toxicological studies of arsenic.

  4. Near-ambient ozone concentrations reduce the vigor of Betula and Populus species in Finland.

    Science.gov (United States)

    Oksanen, Elina; Manninen, Sirkku; Vapaavuori, Elina; Holopainen, Toini

    2009-12-01

    In this review the main growth responses of Finnish birch (Betula pendula, B. pubescens) and aspen species (Populus tremula and P. tremuloides x P. tremula) are correlated with ozone exposure, indicated as the AOT40 value. Data are derived from 23 different laboratory, open-top chamber, and free-air fumigation experiments. Our results indicate that these tree species are sensitive to increasing ozone concentrations, though high intraspecific variation exists. The roots are the most vulnerable targets in both genera. These growth reductions, determined from trees grown under optimal nutrient and water supply, were generally accompanied by increased visible foliar injuries, carbon allocation toward defensive compounds, reduced carbohydrate contents of leaves, impaired photosynthesis processes, disturbances in stomatal function, and earlier autumn senescence. Because both genera have shown complex ozone defense and response mechanisms, which are modified by variable environmental conditions, a mechanistically based approach is necessary for accurate ozone risk assessment.

  5. The effect of Ni on concentration of the most abundant essential cations in several Brassica species

    Directory of Open Access Journals (Sweden)

    Putnik-Delić Marina I.

    2014-01-01

    Full Text Available Some plants from the genus Brassica have the ability to tolerate excessive concentrations of heavy metals, including Ni. Considering the fact that Ni is a very toxic element for living beings we wanted to examine its influence on some species from genus Brassicaceae. The aim of this study was to investigate the effect of Ni on distribution and accumulation of essential macronutrients from the standpoint of food quality and phytoremediation potential. Experiments were performed using winter (W and spring (S varieties of rapeseed (Brassica napus, L., white mustard (Brassica alba, L., black mustard (Brassica nigra, L. and turnip (Brassica rapa, L.. The seeds were exposed to 10 μM Ni from the beginning of germination. Plants were grown in water cultures, in semi-controlled conditions of a greenhouse, on ½ strength Hoagland solution to which was added Ni in the same concentration as during germination. Concentrations and distribution of Ca, Mg, K in leaf and stem were altered in the presence of increased concentration of Ni. Significant differences were found between the control and Ni-treated plants as well as among the genotypes. [Projekat Ministarstva nauke Republike Srbije, br. TR 31036 i br. TR 31016

  6. Blood BDNF concentrations reflect brain-tissue BDNF levels across species

    DEFF Research Database (Denmark)

    Klein, Anders B; Williamson, Rebecca; Santini, Martin A

    2011-01-01

    Brain-derived neurotrophic factor (BDNF) is involved in synaptic plasticity, neuronal differentiation and survival of neurons. Observations of decreased serum BDNF levels in patients with neuropsychiatric disorders have highlighted the potential of BDNF as a biomarker, but so far there have been...... no studies directly comparing blood BDNF levels to brain BDNF levels in different species. We examined blood, serum, plasma and brain-tissue BDNF levels in three different mammalian species: rat, pig, and mouse, using an ELISA method. As a control, we included an analysis of blood and brain tissue from...... conditional BDNF knockout mice and their wild-type littermates. Whereas BDNF could readily be measured in rat blood, plasma and brain tissue, it was undetectable in mouse blood. In pigs, whole-blood levels of BDNF could not be measured with a commercially available ELISA kit, but pig plasma BDNF levels (mean...

  7. Blood BDNF concentrations reflect brain-tissue BDNF levels across species

    DEFF Research Database (Denmark)

    Klein, Anders B; Williamson, Rebecca; Santini, Martin A

    2011-01-01

    no studies directly comparing blood BDNF levels to brain BDNF levels in different species. We examined blood, serum, plasma and brain-tissue BDNF levels in three different mammalian species: rat, pig, and mouse, using an ELISA method. As a control, we included an analysis of blood and brain tissue from......Brain-derived neurotrophic factor (BDNF) is involved in synaptic plasticity, neuronal differentiation and survival of neurons. Observations of decreased serum BDNF levels in patients with neuropsychiatric disorders have highlighted the potential of BDNF as a biomarker, but so far there have been...... conditional BDNF knockout mice and their wild-type littermates. Whereas BDNF could readily be measured in rat blood, plasma and brain tissue, it was undetectable in mouse blood. In pigs, whole-blood levels of BDNF could not be measured with a commercially available ELISA kit, but pig plasma BDNF levels (mean...

  8. Comparative analysis the selenium concentration in grains of wheat and barley species

    International Nuclear Information System (INIS)

    Jalal, F.; Arif, M.; Munsif, F.; Ali, K.

    2016-01-01

    Macro and micro nutrients are essential for human health and growth development. It is reported that about three million people are suffering from nutrient deficiencies all over the world. Various sources are available like: vegetables, fruits, fish, meat and cereals to overcome these deficiencies. Among cereals, wheat and barley are main source to meet the requirement of this dietary element. Two year studies were conducted to investigate the Se concentration in grains of different wheat (T. aestivum L., T. turgidum L. and T. durum L.) and barley (H. spontaneum L. and H. vulgare L.) species originated from different parts of the world. Results indicated that the durum and emmer wheat grains contain higher Se level in both studied years (70.5 and 72.9 micro g kg-1 in 2012 and 74.1 and 73.2 microg kg-1 in 2013 respectively). Among H. spontaneum L. collected from six populations, Mahola population of barley showed remarkable variations in grain Se concentration ranged from 88.3-437.2 and 90.2-439.5 micro g kg-1 in 2012 and 2013 respectively. The information obtained from the findings helps in identifying the lines of wild barley that have more Se uptake and accumulation capability. According to the conclusion of the study that H. Spontaneum L. had greater genetic variation for Se as compare to other species of wheat and barley. (author)

  9. The uropathogenic species Staphylococcus saprophyticus tolerates a high concentration of D-serine.

    Science.gov (United States)

    Sakinç, Türkân; Michalski, Nadine; Kleine, Britta; Gatermann, Sören G

    2009-10-01

    Human urine contains a relatively high concentration of d-serine, which is toxic to several nonuropathogenic bacteria, but can be utilized or detoxified by uropathogenic Escherichia coli (UPEC). The sequenced genome of uropathogenic Staphylococcus saprophyticus contains a gene with homology to the d-serine deaminase gene (dsdA) of UPEC. We found the gene in several clinical isolates of S. saprophyticus; however, the gene was absent in Staphylococcus xylosus and Staphylococcus cohnii, phylogenetically close relatives of S. saprophyticus, and could also not be detected in isolates of Staphylococcus aureus, Staphylococcus epidermidis and 13 other staphylococcal species. In addition, the genomes of other sequenced staphylococci do not harbor homologues of this operon. Interestingly, S. saprophyticus could grow in media supplemented with relatively high concentrations of d-serine, whereas S. aureus, S. epidermidis and other staphylococcal species could not. The association of the dsdA gene with growth in media including d-serine was proved by introducing the gene into S. aureus Newman. Given the fact that UPEC and S. saprophyticus tolerate this compound, d-serine utilization and detoxification may be a general property of uropathogenic bacteria. © 2009 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  10. Bacterial Species and Biochemical Characteristic Investigations of Nostoc flagelliforme Concentrates during its Storage.

    Science.gov (United States)

    Yue, Lifang; Lv, Hexin; Zhen, Jing; Jiang, Shengping; Jia, Shiru; Shen, Shigang; Gao, Lu; Dai, Yujie

    2016-04-28

    Preservation of fresh algae plays an important role in algae seed subculture and aquaculture. The determination and examination of the changes of cell viability, composition, and bacterial species during storage would help to take suitable preservation methods to prolong the preservation time of fresh algae. Nostoc flagelliforme is a kind of edible cyanobacterium with important herbal and dietary values. This article investigated the changes of bacterial species and biochemical characteristics of fresh N. flagelliforme concentrate during natural storage. It was found that the viability of cells decreased along with the storage time. Fourteen bacteria strains in the algae concentrate were identified by PCR-DGGE and were grouped into four phyla, including Cyanobacteria, Firmicutes, Proteobacteria, and Bacteroidetes. Among them, Enterococcus viikkiensis may be a concern in the preservation. Eleven volatile organic compounds were identified from N. flagelliforme cells, in which geosmin could be treated as an indicator of the freshness of N. flagelliforme. The occurrence of indole compound may be an indicator of the degradation of cells.

  11. Evaluation of a Method for Quantifying Eugenol Concentrations in the Fillet Tissue from Freshwater Fish Species.

    Science.gov (United States)

    Meinertz, Jeffery R; Schreier, Theresa M; Porcher, Scott T; Smerud, Justin R

    2016-01-01

    AQUI-S 20E(®) (active ingredient, eugenol; AQUI-S New Zealand Ltd, Lower Hutt, New Zealand) is being pursued for approval as an immediate-release sedative in the United States. A validated method to quantify the primary residue (the marker residue) in fillet tissue from AQUI-S 20E-exposed fish was needed. A method was evaluated for determining concentrations of the AQUI-S 20E marker residue, eugenol, in freshwater fish fillet tissue. Method accuracies from fillet tissue fortified at nominal concentrations of 0.15, 1, and 60 μg/g from six fish species ranged from 88-102%. Within-day and between-day method precisions (% CV) from the fortified tissue were ≤8.4% CV. There were no coextracted compounds from the control fillet tissue of seven fish species that interfered with eugenol analyses. Six compounds used as aquaculture drugs did not interfere with eugenol analyses. The lower limit of quantitation (LLOQ) was 0.012 μg/g. The method was robust, i.e., in most cases, minor changes to the method did not impact method performance. Eugenol was stable in acetonitrile-water (3 + 7, v/v) for at least 14 days, in fillet tissue extracts for 4 days, and in fillet tissue stored at ~ -80°C for at least 84 days.

  12. Determination of the soil hazardous concentrations of bisphenol A using the species sensitivity approach.

    Science.gov (United States)

    Kwak, Jin Il; Moon, Jongmin; Kim, Dokyung; Cui, Rongxue; An, Youn-Joo

    2018-02-15

    This study describes the determination of the species sensitivity distribution (SSD)-based soil hazardous contamination of bisphenol A for environmental risk assessment. We conducted a battery of bioassays, including acute assays using eight species from six different taxonomic groups and chronic assays using five species from four different taxonomic groups. We determined that our dataset satisfied Australia & New Zealand's guidelines for applying the SSD methodology. Finally, the chronic soil HC 5 and HC 50 values for bisphenol A were estimated to be 13.7 and 74.7mg/kg soil, respectively, for soil ecosystem protection against chronic exposure using the data generated from this and previous studies. Because the soil standard values of bisphenol A for protection of the soil ecosystem are not currently available, the HC values of bisphenol A that we suggested based on the SSD approach would be applied as fundamental data to establish soil standards of bisphenol A for soil ecosystem protection. To our knowledge, this is the first study reporting the soil hazardous concentration of bisphenol A for environmental risk assessment. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Persistent organic pollutant concentrations in blubber of 16 species of cetaceans stranded in the Pacific Islands from 1997 through 2011.

    Science.gov (United States)

    Bachman, Melannie J; Keller, Jennifer M; West, Kristi L; Jensen, Brenda A

    2014-08-01

    Persistent organic pollutants (POPs) are toxic man-made chemicals that bioaccumulate and biomagnify in food webs, making them a ubiquitous threat to the marine environment. Although many studies have determined concentrations of POPs in top predators, no studies have quantified POPs in stranded cetaceans within the last 30 years around the Hawaiian Islands. A suite of POPs was measured in the blubber of 16 cetacean species that stranded in the tropical Pacific, including Hawai'i from 1997 to 2011. The sample set includes odontocetes (n=39) and mysticetes (n=3). Median (range) contaminant concentrations in ng/g lipid for the most representative species category (delphinids excluding killer whales [n=27]) are: 9650 (44.4-99,100) for ∑DDTs, 6240 (40.8-50,200) for ∑PCBs, 1380 (6.73-9520) for ∑chlordanes, 1230 (13.4-5510) for ∑toxaphenes, 269 (1.99-10,100) for ∑PBDEs, 280 (2.14-4190) for mirex, 176 (5.43-857) for HCB, 48.1 (0.063), but sex/age class influences were evident with adult males exhibiting greater contaminant loads than adult females and juveniles for ∑DDT, ∑PCBs, ∑CHLs, and mirex (p≤0.036). POP concentrations were lower in mysticetes than odontocetes for many compound classes (p≤0.003). p,p'-DDE/∑DDTs ratios were greater than 0.6 for all species except humpback whales, suggesting exposure to an old DDT source. These POP levels are high enough to warrant concern and continued monitoring. Published by Elsevier B.V.

  14. Heavy metal concentrations in some oyster species of the Caribbean coast of Columbia. Zur Belastung einiger Muschelarten von der karibischen Kueste Kolumbiens mit Schwermetallen

    Energy Technology Data Exchange (ETDEWEB)

    Campos, N.H.

    1984-01-01

    Heavy metal concentrations (Cd, Cu, Pb) were measured in oysters (Crassostrea rhizophorae) and two species of tree oysters (Isognomon alatus and I. bicolor) at various points of the Caribbean coast of Columbia. Samples were taken at 4 different times of the year. Cd and Cu concentrations were highest in oysters; Pb concentrations did not differ between the species. The annual curve was similar for all heavy metals, with maximum concentrations in the dry season. In the area investigated, the WHO limiting values for daily Cd intake with oysters may be exceeded at times in most places, while the daily lead intake was found to be below the WHO limiting values. A comparison with other regions of the world shows that Cd and Pb concentrations in molluscs are high at the Caribbean coast.

  15. Heavy metal concentrations in macroalgae species from Sinop coasts of the Southern Black Sea

    Directory of Open Access Journals (Sweden)

    Levent Bat

    2016-10-01

    Full Text Available Objective: To determine the concentrations of Fe, Zn, Ni, Cu, Mn, Pb, Cd and Co in macroalgae from Sinop coasts of the Sounthern Black Sea. Methods: Chlorophyta-green algae (Chaetomorpha spp., Cladophora spp., Ulva linza, Ulva intestinalis, Ulva lactuca, Ulva rigida; Ochrophyta-brown alga [Cystoseira barbata (C. barbata] and Rhodophyta-red algae (Ceramium spp., Corallina panizzoi were collected seasonally in the year 2010 from the upper infralittoral zone of inner harbour, outer harbour, Gerze and Ayancık of Sinop coasts of the Black Sea. The samples were analysed by atomic absorption spectrophotometer in order to determine heavy metal levels in different algal division species along Sinop coasts and to provide information of marine environment quality as marine strategy framework directive is aimed to ensure good environmental status of the seas by 2020 in the European Union. Results: The results showed that metal concentrations in all studied green algae, brown alga and red algae increase in the order: Cd < Co < Ni < Pb < Cu < Zn < Mn < Fe, Cd < Co < Cu < Ni < Pb < Mn < Zn < Fe and Co < Cd < Ni < Cu < Pb < Mn < Zn < Fe, respectively. In all divisions, among the essential elements the highest concentrations exhibited by Fe, in Gerze station- (2328 ± 89 µg/g dry weight in Chaetomorpha spp.; (2143 ± 78 µg/g dry weight in C. barbata and (968 ± 20 µg/g dry weight in Ceramium spp. Conclusions: The highest accumulation of different metals in the analysed algae species were: Fe and Co in Chaetomorpha spp., Zn in C. barbata, Ni and Cu in Ulva linza, Mn in Ulva intestinalis, Pb and Cd in Corallina panizzoi.

  16. Transcutaneous Measurement of Blood Analyte Concentration Using Raman Spectroscopy

    Science.gov (United States)

    Barman, Ishan; Singh, Gajendra P.; Dasari, Ramachandra R.; Feld, Michael S.

    2008-11-01

    Diabetes mellitus is a chronic disorder, affecting nearly 200 million people worldwide. Acute complications, such as hypoglycemia, cardiovascular disease and retinal damage, may occur if the disease is not adequately controlled. As diabetes has no known cure, tight control of glucose levels is critical for the prevention of such complications. Given the necessity for regular monitoring of blood glucose, development of non-invasive glucose detection devices is essential to improve the quality of life in diabetic patients. The commercially available glucose sensors measure the interstitial fluid glucose by electrochemical detection. However, these sensors have severe limitations, primarily related to their invasive nature and lack of stability. This necessitates the development of a truly non-invasive glucose detection technique. NIR Raman Spectroscopy, which combines the substantial penetration depth of NIR light with the excellent chemical specificity of Raman spectroscopy, provides an excellent tool to meet the challenges involved. Additionally, it enables simultaneous determination of multiple blood analytes. Our laboratory has pioneered the use of Raman spectroscopy for blood analytes' detection in biological media. The preliminary success of our non-invasive glucose measurements both in vitro (such as in serum and blood) and in vivo has provided the foundation for the development of feasible clinical systems. However, successful application of this technology still faces a few hurdles, highlighted by the problems of tissue luminescence and selection of appropriate reference concentration. In this article we explore possible avenues to overcome these challenges so that prospective prediction accuracy of blood analytes can be brought to clinically acceptable levels.

  17. Mixing layer height measurements determines influence of meteorology on air pollutant concentrations in urban area

    Science.gov (United States)

    Schäfer, Klaus; Blumenstock, Thomas; Bonn, Boris; Gerwig, Holger; Hase, Frank; Münkel, Christoph; Nothard, Rainer; von Schneidemesser, Erika

    2015-10-01

    Mixing layer height (MLH) is a key parameter to determine the influence of meteorological parameters upon air pollutants such as trace gas species and particulate concentrations near the surface. Meteorology, and MLH as a key parameter, affect the budget of emission source strengths, deposition, and accumulation. However, greater possibilities for the application of MLH data have been identified in recent years. Here, the results of measurements in Berlin in 2014 are shown and discussed. The concentrations of NO, NO2, O3, CO, PM1, PM2.5, PM10 and about 70 volatile organic compounds (anthropogenic and biogenic of origin) as well as particle size distributions and contributions of SOA and soot species to PM were measured at the urban background station of the Berlin air quality network (BLUME) in Nansenstr./Framstr., Berlin-Neukölln. A Vaisala ceilometer CL51, which is a commercial mini-lidar system, was applied at that site to detect the layers of the lower atmosphere in real time. Special software for these ceilometers with MATLAB provided routine retrievals of MLH from vertical profiles of laser backscatter data. Five portable Bruker EM27/SUN FTIR spectrometers were set up around Berlin to detect column averaged abundances of CO2 and CH4 by solar absorption spectrometry. Correlation analyses were used to show the coupling of temporal variations of trace gas compounds and PM with MLH. Significant influences of MLH upon NO, NO2, PM10, PM2.5, PM1 and toluene (marker for traffic emissions) concentrations as well as particle number concentrations in the size modes 70 - 100 nm, 100 - 200 nm and 200 - 500 nm on the basis of averaged diurnal courses were found. Further, MLH was taken as important auxiliary information about the development of the boundary layer during each day of observations, which was required for the proper estimation of CO2 and CH4 source strengths from Berlin on the basis of atmospheric column density measurements.

  18. Description and measurement of concentration problems in depressed patients.

    Science.gov (United States)

    Watts, F N; Sharrock, R

    1985-05-01

    Depressed patients commonly complain of concentration problems, yet these have seldom been the focus of systematic investigation. A structured interview about concentration problems was administered to a group of relatively severely depressed patients. Problems in reading and watching television were the most common, and were highly correlated with each other. Direct report of the number of concentration lapses on a reading task was the most generally satisfactory task-performance correlate of complaints of reading/TV concentration problems. Evidence both from this task and from the interview suggests that depressive concentration problems may often be due to 'mind-wandering'. The correlations with concentration problems with the severity and endogeneity of depression and with state anxiety were generally similar.

  19. Temporal trends in 137Cs concentrations in the bark, sapwood, heartwood, and whole wood of four tree species in Japanese forests from 2011 to 2016.

    Science.gov (United States)

    Ohashi, Shinta; Kuroda, Katsushi; Takano, Tsutomu; Suzuki, Youki; Fujiwara, Takeshi; Abe, Hisashi; Kagawa, Akira; Sugiyama, Masaki; Kubojima, Yoshitaka; Zhang, Chunhua; Yamamoto, Koichi

    2017-11-01

    To understand the changes in radiocesium ( 137 Cs) concentrations in stem woods after the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident, we investigated 137 Cs concentrations in the bark, sapwood, heartwood, and whole wood of four major tree species at multiple sites with different levels of radiocesium deposition from the FDNPP accident since 2011 (since 2012 at some sites): Japanese cedar at four sites, hinoki cypress and Japanese konara oak at two sites, and Japanese red pine at one site. Our previous report on 137 Cs concentrations in bark and whole wood samples collected from 2011 to 2015 suggested that temporal variations were different among sites even within the same species. In the present study, we provided data on bark and whole wood samples in 2016 and separately measured 137 Cs concentrations in sapwood and heartwood samples from 2011 to 2016; we further discussed temporal trends in 137 Cs concentrations in each part of tree stems, particularly those in 137 Cs distributions between sapwood and heartwood, in relation to their species and site dependencies. Temporal trends in bark and whole wood samples collected from 2011 to 2016 were consistent with those reported in samples collected from 2011 to 2015. Temporal variations in 137 Cs concentrations in barks showed either a decreasing trend or no clear trend, implying that 137 Cs deposition in barks is inhomogeneous and that decontamination is relatively slow in some cases. Temporal trends in 137 Cs concentrations in sapwood, heartwood, and whole wood were different among species and also among sites within the same species. Relatively common trends within the same species, which were increasing, were observed in cedar heartwood, and in oak sapwood and whole wood. On the other hand, the ratio of 137 Cs concentration in heartwood to that in sapwood (fresh weight basis) was commonly increased to more than 2 in cedar, although distinct temporal trends were not found in the other species, for

  20. Methane concentration and isotopic composition measurements with a mid-infrared quantum-cascade laser

    Science.gov (United States)

    Kosterev, A. A.; Curl, R. F.; Tittel, F. K.; Gmachl, C.; Capasso, F.; Sivco, D. L.; Baillargeon, J. N.; Hutchinson, A. L.; Cho, A. Y.

    1999-01-01

    A quantum-cascade laser operating at a wavelength of 8.1 micrometers was used for high-sensitivity absorption spectroscopy of methane (CH4). The laser frequency was continuously scanned with current over more than 3 cm-1, and absorption spectra of the CH4 nu 4 P branch were recorded. The measured laser linewidth was 50 MHz. A CH4 concentration of 15.6 parts in 10(6) ( ppm) in 50 Torr of air was measured in a 43-cm path length with +/- 0.5-ppm accuracy when the signal was averaged over 400 scans. The minimum detectable absorption in such direct absorption measurements is estimated to be 1.1 x 10(-4). The content of 13CH4 and CH3D species in a CH4 sample was determined.

  1. Kinetic model for predicting the concentrations of active halogen species in chlorinated saline cooling waters

    International Nuclear Information System (INIS)

    Lietzke, M.H.; Haag, W.R.

    1979-01-01

    A kinetic model for predicting the composition of chlorinated water discharged from power plants using fresh water for cooling was previously reported. The model has now been extended to be applicable to power plants located on estuaries or on the seacoast where saline water is used for cooling purposes. When chloride is added to seawater to prevent biofouling in cooling systems, bromine is liberated. Since this reaction proceeds at a finite rate there is a competition between the bromine (i.e., hypobromous acid) and the added chlorine (i.e., hypochlorous acid) for halogenation of any amine species present in the water. Hence not only chloramines but also bromamines and bromochloramines will be formed, with the relative concentrations a function of the pH, temperature, and salinity of the water. The kinetic model takes into account the chemical reactions leading to the formation and disappearance of the more important halamines and hypohalous acids likely to be encountered in chlorinated saline water

  2. Species differences in total mercury concentration in gulls from the Gulf of Gdansk (Southern Baltic).

    Science.gov (United States)

    Szumiło-Pilarska, Emilia; Grajewska, Agnieszka; Falkowska, Lucyna; Hajdrych, Julia; Meissner, Włodzimierz; Frączek, Tomasz; Bełdowska, Magdalena; Bzoma, Szymon

    2016-01-01

    Aquatic birds occupy a high position in the trophic pyramid of the Baltic Sea. This means that they accumulate the greatest amount of harmful substances, including mercury, in their bodies. This element penetrates into their systems mainly via the alimentary canal. The amount of mercury absorbed from food depends on how badly the environment is polluted with this metal. The aim of this study was to discover the concentrations of total mercury (HgT) in the contour feathers, muscles, brain, lungs, liver, kidneys, heart and blood of four gull species Herring Gull (Larus argentatus), Common Gull (Larus canus), Black-headed Gull (Larus ridibundus) and Great Black-backed Gull (Larus marinus) and organic mercury (Hgorg) in the liver and brain of Herring Gull. The most important characteristic of the results obtained for the studied gulls was the statistically significant differences between the four species, probably resulting from their different diets-confirmed by stable-isotopes analysis (δ(15)N and δ(13)C). A logarithmic dependence was found between HgT in the blood and HgT in the brain of the Herring Gull. The authors suggest that among gulls burdened with the greatest mercury load, it is possible that the brain is protected by higher Hg accumulation in the muscles. The percentage share of Hgorg in the brain and liver of the Herring Gull depended on the concentration of HgT in these tissues and was always higher in the brain. In none of the cases, did the mercury levels assayed in the internal gulls' tissues exceed values associated with adverse health effects. Copyright © 2015 Elsevier GmbH. All rights reserved.

  3. Effect of N deposition on tree amino acid concentrations in two Sphagnum species

    Energy Technology Data Exchange (ETDEWEB)

    Karsisto, M; Kitunen, V [Finnish Forest Research Inst., Vantaa (Finland). Vantaa Research Centre; Jauhiainen, J [Joensuu Univ. (Finland). Dept. of Biology; Vasander, H [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1997-12-31

    Nitrogen saturation of ecosystems occurs when the availability of nitrogen is not a growth limiting factor. This situation can be reached through fertilisation or by nitrogen deposition. Prolonged nitrogen saturation may overload the ecosystem and cause changes in the vigour and eventually in the composition of plant communities. But before this stage is reached, certain changes in nitrogen metabolism occur. These changes can be used as an early warning of nitrogen overload to ecosystems. A change in the amino acid pool of plants has been used as an indication of various kind of stress, including, temperature, nutrient imbalance, shading, drought or excess water. It has been postulated that such stresses have an effect on protein synthesis but not on the nitrogen uptake of plants. The result is an increase in the concentration of NH{sub 4}{sup +} ions in plant cells, which may have toxic effects to the plant and the processes that assimilate the free NH{sub 4}{sup +} ions. One of such process is the synthesis of amino acids, especially those containing a significant proportion of nitrogen, e.g. arginine, glutamine and asparagine. This study about the quantification of amino acids in two species of Sphagnum mosses is part of a larger study, the aim of which is to clarify how a number of Sphagnum species will cope with climatic change and nitrogen deposition. Sphagna are the most important members of the peat forming communities in the boreal zone. Sphagnum communities are formed by species specialised to grow in conditions of low nutrient availability, mainly provided via deposition. The present structure and composition of mire communities may be endangered due to elevated levels of nitrogen deposition that have persisted over the last few decades. (20 refs.)

  4. Effect of N deposition on tree amino acid concentrations in two Sphagnum species

    Energy Technology Data Exchange (ETDEWEB)

    Karsisto, M.; Kitunen, V. [Finnish Forest Research Inst., Vantaa (Finland). Vantaa Research Centre; Jauhiainen, J. [Joensuu Univ. (Finland). Dept. of Biology; Vasander, H. [Helsinki Univ. (Finland). Dept. of Forest Ecology

    1996-12-31

    Nitrogen saturation of ecosystems occurs when the availability of nitrogen is not a growth limiting factor. This situation can be reached through fertilisation or by nitrogen deposition. Prolonged nitrogen saturation may overload the ecosystem and cause changes in the vigour and eventually in the composition of plant communities. But before this stage is reached, certain changes in nitrogen metabolism occur. These changes can be used as an early warning of nitrogen overload to ecosystems. A change in the amino acid pool of plants has been used as an indication of various kind of stress, including, temperature, nutrient imbalance, shading, drought or excess water. It has been postulated that such stresses have an effect on protein synthesis but not on the nitrogen uptake of plants. The result is an increase in the concentration of NH{sub 4}{sup +} ions in plant cells, which may have toxic effects to the plant and the processes that assimilate the free NH{sub 4}{sup +} ions. One of such process is the synthesis of amino acids, especially those containing a significant proportion of nitrogen, e.g. arginine, glutamine and asparagine. This study about the quantification of amino acids in two species of Sphagnum mosses is part of a larger study, the aim of which is to clarify how a number of Sphagnum species will cope with climatic change and nitrogen deposition. Sphagna are the most important members of the peat forming communities in the boreal zone. Sphagnum communities are formed by species specialised to grow in conditions of low nutrient availability, mainly provided via deposition. The present structure and composition of mire communities may be endangered due to elevated levels of nitrogen deposition that have persisted over the last few decades. (20 refs.)

  5. Measurement of local interfacial area concentration in boiling loop

    International Nuclear Information System (INIS)

    Kyoung, Ho Kang; Byong, Jo Yun; Goon, Cherl Park

    1995-01-01

    An accurate prediction of two-phase flow is essential to many energy systems, including nuclear reactors. To model the two-phase flow, detailed information on the internal flow structure is required. The void fraction and interfacial area concentration are important fundamental parameters characterizing the internal structure of two-phase flow. The interfacial area concentration is defined as the available interfacial area per unit volume of the two-phase mixture in calculations of the interfacial transport of mass, momentum, and energy. Although a number of studies have been made in this area, the interfacial area concentration in two-phase flow has not been sufficiently investigated either experimentally or analytically. Most existing models for interfacial area concentration are limited to area-averaged interfacial area concentration in a flow channel. And the studies on local interfacial area concentration are limited to the case of air-water two-phase flow. However, the internal flow structure of steam-water two-phase flow having various bubble sizes could be quite different from that of air-water two-phase flow, the reliability of which weak in practical applications. In this study, the local interfacial area concentration steam-water two-phase flow has been investigated experimentally in a circular boiling tube having a heating rod in the center, and for the low flow with liquid superficial velocity <1 m/s

  6. Measurements of Radon Concentration in Yemen Using Spark Counter

    International Nuclear Information System (INIS)

    Arafa, W.; Abou-Leila, M.; Hafiz, M.E.; Al-Glal, N.

    2011-01-01

    Spark counter has been designed and realized and the optimum applied voltage was found to be 600 V. Excellent consistent agreements was observed between counted number of tracks by spark counter and reading by optical microscope. Radon concentration in some houses in Sana'a and Hodeidah cities in Yemen had been performed using LR-115 SSNTD and spark counter system. The average radon concentration in both cities was far lower the alert value. The results showed that radon concentration in the metropolitan area Sana'a was higher than that in Hodeidah city. Also, it was observed that old residential houses had higher levels of radon concentrations have compared to newly built houses in the metropolitan area Sana'a

  7. Lead Concentrations in Soils and Some Wild Plant Species Along Two Busy Roads in Pakistan.

    Science.gov (United States)

    Khalid, Noreen; Hussain, Mumtaz; Young, Hillary S; Ashraf, Muhammad; Hameed, Mansoor; Ahmad, Rashid

    2018-02-01

    This study assessed the level of Pb in soil and five wild plant species (Calotropis procera, Datura alba, Parthenium hysterophorus, Cenchrus ciliaris and Ricinus communis) during all the four seasons. Two busy roads varying in age and traffic volume were selected i.e., Faisalabad-Sargodha road (FSR) and Pindi Bhattian to Lillah (M-2) in the Punjab, Pakistan. Results showed raised levels of Pb in both plants and soil samples along both roads. The range of Pb concentration in plants was 0.08-3.98 and 1.95-4.74 mg kg - 1 for soil. Higher Pb contamination was recorded along FSR road as compared to M-2. Among seasons, the higher Pb concentration was found during summer, probably due to very high temperature. Among all the plants studied, Calotropis procera accumulated the highest level (3.98 mg kg - 1 dry wt.) of Pb; Thus, it can be used as good biomonitor/phytoremediator at Pb contaminated areas.

  8. Cannabis species and cannabinoid concentration preference among sleep-disturbed medicinal cannabis users.

    Science.gov (United States)

    Belendiuk, Katherine A; Babson, Kimberly A; Vandrey, Ryan; Bonn-Miller, Marcel O

    2015-11-01

    Individuals report using cannabis for the promotion of sleep, and the effects of cannabis on sleep may vary by cannabis species. Little research has documented preferences for particular cannabis types or cannabinoid concentrations as a function of use for sleep disturbances. 163 adults purchasing medical cannabis for a physical or mental health condition at a cannabis dispensary were recruited. They provided self-report of (a) whether cannabis use was intended to help with sleep problems (e.g. insomnia, nightmares), (b) sleep quality (PSQI), (c) cannabis use (including preferred type), and (d) symptoms of DSM-5 cannabis dependence. 81 participants reported using cannabis for the management of insomnia and 14 participants reported using cannabis to reduce nightmares. Individuals using cannabis to manage nightmares preferred sativa to indica strains (Fisher's exact test (2) = 6.83, p < 0.05), and sativa users were less likely to endorse DSM-5 cannabis dependence compared with those who preferred indica strains (χ(2)(2) = 4.09, p < 0.05). Individuals with current insomnia (t(9) = 3.30, p < 0.01) and greater sleep latency (F(3,6) = 46.7, p < 0.001) were more likely to report using strains of cannabis with significantly higher concentrations of CBD. Individuals who reported at least weekly use of hypnotic medications used cannabis with lower THC concentrations compared to those who used sleep medications less frequently than weekly (t(17) = 2.40, p < 0.05). Associations between sleep characteristics and the type of cannabis used were observed in this convenience sample of individuals using cannabis for the management of sleep disturbances. Controlled prospective studies are needed to better characterize the impact that specific components of cannabis have on sleep. Copyright © 2015. Published by Elsevier Ltd.

  9. Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements

    Science.gov (United States)

    Ridder, Trent D.; Ver Steeg, Benjamin J.; Laaksonen, Bentley D.

    2009-09-01

    Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alternative, as no body fluids are required. The purpose of this work is to report the results of a 36-subject clinical study designed to characterize tissue alcohol measured using near-infrared spectroscopy relative to venous blood, capillary blood, and breath alcohol. Comparison of blood and breath alcohol concentrations demonstrated significant differences in alcohol concentration [root mean square of 9.0 to 13.5 mg/dL] that were attributable to both assay accuracy and precision as well as alcohol pharmacokinetics. A first-order kinetic model was used to estimate the contribution of alcohol pharmacokinetics to the differences in concentration observed between the blood, breath, and tissue assays. All pair-wise combinations of alcohol assays were investigated, and the fraction of the alcohol concentration variance explained by pharmacokinetics ranged from 41.0% to 83.5%. Accounting for pharmacokinetic concentration differences, the accuracy and precision of the spectroscopic tissue assay were found to be comparable to those of the blood and breath assays.

  10. Method for sensing and measuring a concentration or partial pressure of a reactant used in a redox reaction

    Science.gov (United States)

    Findl, E.

    1984-12-21

    A method for sensing or measuring the partial pressure or concentration of an electroactive species used in conjunction with an electrolyte, the method being characterized by providing a constant current between an anode and a cathode of an electrolyte-containing cell, while measuring changes in voltage that occur between either the anode and cathode or between a reference electrode and one of the main electrodes of the cell, thereby to determine the concentration or partial pressure of the electro-active species as a function of said measured voltage changes. The method of the invention can be practiced using either a cell having only an anode and a cathode, or using a cell having an anode and a cathode in combination with a reference electrode. Accurate measurements of small concentrations or partial pressures of electro-active species are obtainable with the method of the invention, by using constant currents of only a few microamperes between the anode and cathode of the cell, while the concentration-determining voltage is measured.

  11. Body size and measurement of species diversity in large grazing mammals

    NARCIS (Netherlands)

    Oindo, B.O.

    2002-01-01

    Species are by definition different from each other. This fact favours ranking rather than additive indices. However, ecologists have measured species diversity in terms of species richness, or by combining species richness with the relative abundance of species within an area. Both methods raise

  12. The Critical Micelle Concentration of Asphaltenes as Measured by Calorimetry

    DEFF Research Database (Denmark)

    Andersen, Simon Ivar; Christensen, S. D.

    2000-01-01

    Micellization of asphaltenes in solution has been investigated using a micro calorimetric titration procedure (Andersen, S. I.; Birdi, K. S. J Colloid Interface Sci. 1991, 142, 497). The method uses the analysis of heat of dissociation and dilution of asphaltene micelles when a pure solvent (or...... solvent mixture) is titrated with a solution of asphaltene in the same solvent. The asphaltene concentration of the injected solution is at a level above the critical micelle concentration (CMC). In the present paper the procedure is applied in investigation of asphaltenes as well as subfractions...

  13. Concentration Polarization to Measure Nano-pore Accessibility

    NARCIS (Netherlands)

    Solsona, Miguel; Eijkel, Jan C.T.; Olthuis, Wouter; Papadimitriou, Vasileios; van den Berg, Albert; Abelmann, Leon; Weckhuysen, Bert M.; Nieuwelink, A. E.

    2017-01-01

    Understanding the deactivation process in porous catalysts is of tremendous economic significance. We demonstrate the feasibility of using the concentration polarization method to obtain the pore accessibility distribution at single particle level for the first time. By using this technique we could

  14. The measurement of airborne rodon daughter concentrations in the atmosphere

    International Nuclear Information System (INIS)

    Ha, C.W.; Lee, J.K.; Moon, P.S.

    1979-01-01

    A simple method for determining the airborne concentration of radon daughter products has been developed, which is based on gross alpha counting of the air filter collections at several time intervals after completion of air sampling. The concentration of each nuclide is then obtained from an equation involving the alpha disintegrations, the sampling time, and the known numerical coefficients. The state of radioactive disequilibrium is also inventigated. The atmosphere sampled in the TRIGA Mark-III reactor room was largely in disequilibrium. The extent of radioactive disequilibrium between radon daughter products seems likely depend on sampling times associated with turbulence conditions. The data obtained here will certainly provide useful information on the evaluation of internal exposure and calibration of effluent monitoring instruments. (author)

  15. The analyses of measured nuclide concentration in project ISTC 2670

    International Nuclear Information System (INIS)

    Chrapciak, V.

    2006-01-01

    In this article are analyzed experiments for WWER-440 fuel and compared with theoretical results by new version of the SCALE 5 code: nuclide compositions - measurement in Kurchatov institute for 3.6% - measurement in Dimitrovgrad for 3.6% (project ISTC 2670) The focus is on modules TRITON and ORIGEN-S (Authors)

  16. Development of real-time measurement of methanol-concentration in polymer electrolyte membrane using a local NMR sensor

    International Nuclear Information System (INIS)

    Ogawa, Kuniyasu; Ito, Kohei; Haishi, Tomoyuki

    2007-01-01

    A real-time sensor to measure methanol concentration in polymer electrolyte membrane (PEM) was developed for reducing methanol cross-over in Direct Methanol Fuel Cell (DMFC). The principle of the methanol sensor is based on the chemical shift of CH and OH species under high magnetic field. The sensor consists of a planar surface coil of 1.3 mm outside diameter. NMR signal from PEM being exposed to CH3OH solvent was measured using NMR sensor. Time-dependence changes of methanol concentration in PEM were obtained from analyzing spectrum of NMR signal. (author)

  17. A nonlocal species concentration theory for diffusion and phase changes in electrode particles of lithium ion batteries

    Science.gov (United States)

    Zhang, Tao; Kamlah, Marc

    2018-01-01

    A nonlocal species concentration theory for diffusion and phase changes is introduced from a nonlocal free energy density. It can be applied, say, to electrode materials of lithium ion batteries. This theory incorporates two second-order partial differential equations involving second-order spatial derivatives of species concentration and an additional variable called nonlocal species concentration. Nonlocal species concentration theory can be interpreted as an extension of the Cahn-Hilliard theory. In principle, nonlocal effects beyond an infinitesimal neighborhood are taken into account. In this theory, the nonlocal free energy density is split into the penalty energy density and the variance energy density. The thickness of the interface between two phases in phase segregated states of a material is controlled by a normalized penalty energy coefficient and a characteristic interface length scale. We implemented the theory in COMSOL Multiphysics^{circledR } for a spherically symmetric boundary value problem of lithium insertion into a Li_xMn_2O_4 cathode material particle of a lithium ion battery. The two above-mentioned material parameters controlling the interface are determined for Li_xMn_2O_4 , and the interface evolution is studied. Comparison to the Cahn-Hilliard theory shows that nonlocal species concentration theory is superior when simulating problems where the dimensions of the microstructure such as phase boundaries are of the same order of magnitude as the problem size. This is typically the case in nanosized particles of phase-separating electrode materials. For example, the nonlocality of nonlocal species concentration theory turns out to make the interface of the local concentration field thinner than in Cahn-Hilliard theory.

  18. COMPLEMENTARY APPROACHES TO THE DETERMINATION OF ARSENIC SPECIES RELEVANT TO CONCENTRATED ANIMAL FEEDING OPERATIONS

    Science.gov (United States)

    Ion-exchange chromatography is the most often used analytical approach for arsenicspeciation, due to the weak-acid nature of several of its species. However, no singletechnique can determine all potentially occurring arsenic species, especially in complexe...

  19. Measurement of aerosol concentration with a beta-ray gage

    International Nuclear Information System (INIS)

    Auzac, G. d'; Dubillot, J.

    1978-01-01

    Because dusts in suspension are a dangerous polluting agent, several methods have been used to monitor their concentration. Among these, the beta-ray gage enjoys a privileged position. The authors describe such a gage and discuss the conditions to be observed for it to be capable of giving results comparable to those obtained with manual gravimetric methods. The satisfactory results obtained led to standardization of the method and a whole range of instruments based on this principle are employed in pollution supervising networks and for continuously monitoring industrial emissions [fr

  20. A space-charge treatment of the increased concentration of reactive species at the surface of a ceria solid solution

    Energy Technology Data Exchange (ETDEWEB)

    Zurhelle, Alexander F.; Souza, Roger A. de [Institute of Physical Chemistry, RWTH Aachen University (Germany); Tong, Xiaorui; Mebane, David S. [Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV (United States); Klein, Andreas [Institute of Materials Science, TU Darmstadt (Germany)

    2017-11-13

    A space-charge theory applicable to concentrated solid solutions (Poisson-Cahn theory) was applied to describe quantitatively as a function of temperature and oxygen partial pressure published data obtained by in situ X-ray photoelectron spectroscopy (XPS) for the concentration of Ce{sup 3+} (the reactive species) at the surface of the oxide catalyst Ce{sub 0.8}Sm{sub 0.2}O{sub 1.9}. In contrast to previous theoretical treatments, these calculations clearly indicate that the surface is positively charged and compensated by an attendant negative space-charge zone. The high space-charge potential that develops at the surface (>0.8 V) is demonstrated to be hardly detectable by XPS measurements because of the short extent of the space-charge layer. This approach emphasizes the need to take into account defect interactions and to allow deviations from local charge neutrality when considering the surfaces of oxide catalysts. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  1. Serum concentrations of lipids, vitamin d metabolites, retinol, retinyl esters, tocopherols and selected carotenoids in twelve captive wild felid species at four zoos.

    Science.gov (United States)

    Crissey, Susan D; Ange, Kimberly D; Jacobsen, Krista L; Slifka, Kerri A; Bowen, Phyllis E; Stacewicz-Sapuntzakis, Maria; Langman, Craig B; Sadler, William; Kahn, Stephen; Ward, Ann

    2003-01-01

    Serum concentrations of several nutrients were measured in 12 captive wild felid species including caracal (Felis caracal), cheetah (Acinonyx jubatus), cougar (Felis concolor), fishing cat (Felis viverrinus), leopard (Panthera pardus), lion (Panthera leo), ocelot (Felis pardalis), pallas cat (Felis manul), sand cat (Felis margarita), serval (Felis serval), snow leopard (Panthera uncia) and tiger (Panthera tigris). Diet information was collected for these animals from each participating zoo (Brookfield Zoo, Fort Worth Zoo, Lincoln Park Zoological Gardens and North Carolina Zoological Park). The nutritional composition of the diets at each institution met the probable dietary requirements for each species except for the pallas cat. Blood samples were collected from each animal (n = 69) and analyzed for lipids (total cholesterol, triacylglycerides, HDL cholesterol and LDL cholesterol), vitamin D metabolites [25-hydroxycholecalciferol (25(OH)D) and 1,25-dihydroxycholecalciferol (1,25(OH)(2)D)], vitamin A (retinol, retinyl stearate and retinyl palmitate), vitamin E (alpha- and gamma-tocopherol) and selected carotenoids. Species differences were found for all except triacylglycerides and 1,25(OH)(2)D. Genus differences were found for retinol, retinyl palmitate, retinyl stearate, gamma-tocopherol and beta-carotene. Circulating nutrient concentrations for many of the species in this study have not been reported previously and most have not been compared with the animals' dietary intakes. The large number of animals analyzed provides a substantial base for comparing the serum nutrient concentrations of healthy animals, for both wild and captive exotic species.

  2. Microfabricated Collector-Generator Electrode Sensor for Measuring Absolute pH and Oxygen Concentrations.

    Science.gov (United States)

    Dengler, Adam K; Wightman, R Mark; McCarty, Gregory S

    2015-10-20

    Fast-scan cyclic voltammetry (FSCV) has attracted attention for studying in vivo neurotransmission due to its subsecond temporal resolution, selectivity, and sensitivity. Traditional FSCV measurements use background subtraction to isolate changes in the local electrochemical environment, providing detailed information on fluctuations in the concentration of electroactive species. This background subtraction removes information about constant or slowly changing concentrations. However, determination of background concentrations is still important for understanding functioning brain tissue. For example, neural activity is known to consume oxygen and produce carbon dioxide which affects local levels of oxygen and pH. Here, we present a microfabricated microelectrode array which uses FSCV to detect the absolute levels of oxygen and pH in vitro. The sensor is a collector-generator electrode array with carbon microelectrodes spaced 5 μm apart. In this work, a periodic potential step is applied at the generator producing transient local changes in the electrochemical environment. The collector electrode continuously performs FSCV enabling these induced changes in concentration to be recorded with the sensitivity and selectivity of FSCV. A negative potential step applied at the generator produces a transient local pH shift at the collector. The generator-induced pH signal is detected using FSCV at the collector and correlated to absolute solution pH by postcalibration of the anodic peak position. In addition, in oxygenated solutions a negative potential step at the generator produces hydrogen peroxide by reducing oxygen. Hydrogen peroxide is detected with FSCV at the collector electrode, and the magnitude of the oxidative peak is proportional to absolute oxygen concentrations. Oxygen interference on the pH signal is minimal and can be accounted for with a postcalibration.

  3. Comparison of fungal spores concentrations measured with wideband integrated bioaerosol sensor and Hirst methodology

    Science.gov (United States)

    Fernández-Rodríguez, S.; Tormo-Molina, R.; Lemonis, N.; Clot, B.; O'Connor, D. J.; Sodeau, John R.

    2018-02-01

    The aim of this work was to provide both a comparison of traditional and novel methodologies for airborne spores detection (i.e. the Hirst Burkard trap and WIBS-4) and the first quantitative study of airborne fungal concentrations in Payerne (Western Switzerland) as well as their relation to meteorological parameters. From the traditional method -Hirst trap and microscope analysis-, sixty-three propagule types (spores, sporangia and hyphae) were identified and the average spore concentrations measured over the full period amounted to 4145 ± 263.0 spores/m3. Maximum values were reached on July 19th and on August 6th. Twenty-six spore types reached average levels above 10 spores/m3. Airborne fungal propagules in Payerne showed a clear seasonal pattern, increasing from low values in early spring to maxima in summer. Daily average concentrations above 5000 spores/m3 were almost constant in summer from mid-June onwards. Weather parameters showed a relevant role for determining the observed spore concentrations. Coniferous forest, dominant in the surroundings, may be a relevant source for airborne fungal propagules as their distribution and predominant wind directions are consistent with the origin. The comparison between the two methodologies used in this campaign showed remarkably consistent patterns throughout the campaign. A correlation coefficient of 0.9 (CI 0.76-0.96) was seen between the two over the time period for daily resolutions (Hirst trap and WIBS-4). This apparent co-linearity was seen to fall away once increased resolution was employed. However at higher resolutions upon removal of Cladosporium species from the total fungal concentrations (Hirst trap), an increased correlation coefficient was again noted between the two instruments (R = 0.81 with confidence intervals of 0.74 and 0.86).

  4. The measurement of dissolved and gaseous carbon dioxide concentration

    Science.gov (United States)

    Zosel, J.; Oelßner, W.; Decker, M.; Gerlach, G.; Guth, U.

    2011-07-01

    In this review the basic principles of carbon dioxide sensors and their manifold applications in environmental control, biotechnology, biology, medicine and food industry are reported. Electrochemical CO2 sensors based on the Severinghaus principle and solid electrolyte sensors operating at high temperatures have been manufactured and widely applied already for a long time. Besides these, nowadays infrared, non-dispersive infrared and acoustic CO2 sensors, which use physical measuring methods, are being increasingly used in some fields of application. The advantages and drawbacks of the different sensor technologies are outlined. Electrochemical sensors for the CO2 measurement in aqueous media are pointed out in more detail because of their simple setup and the resulting low costs. A detailed knowledge of the basic detection principles and the windows for their applications is necessary to find an appropriate decision on the technology to be applied for measuring dissolved CO2. In particular the pH value and the composition of the analyte matrix exert important influence on the results of the measurements.

  5. The measurement of dissolved and gaseous carbon dioxide concentration

    International Nuclear Information System (INIS)

    Zosel, J; Oelßner, W; Decker, M; Gerlach, G; Guth, U

    2011-01-01

    In this review the basic principles of carbon dioxide sensors and their manifold applications in environmental control, biotechnology, biology, medicine and food industry are reported. Electrochemical CO 2 sensors based on the Severinghaus principle and solid electrolyte sensors operating at high temperatures have been manufactured and widely applied already for a long time. Besides these, nowadays infrared, non-dispersive infrared and acoustic CO 2 sensors, which use physical measuring methods, are being increasingly used in some fields of application. The advantages and drawbacks of the different sensor technologies are outlined. Electrochemical sensors for the CO 2 measurement in aqueous media are pointed out in more detail because of their simple setup and the resulting low costs. A detailed knowledge of the basic detection principles and the windows for their applications is necessary to find an appropriate decision on the technology to be applied for measuring dissolved CO 2 . In particular the pH value and the composition of the analyte matrix exert important influence on the results of the measurements. (topical review)

  6. Quality control of the concentration measurement of specific radioactive isotopes

    International Nuclear Information System (INIS)

    Loria, Luis Guillermo; Badilla, Mauricio

    2008-01-01

    The counting efficiency of a gamma spectroscopy chain with a Ge (H.p) detector was measured. The Monte Carlo simulation and standard reference materials, in order to calculate the specific activity from 4 reference materials, and from intercomparison samples were used. The purpose was to evaluate the analytical results obtained in the Laboratorio de Espectroscopia Gamma. (author) [es

  7. Concentration of 137Cs and 40K in meat of omnivore and herbivore game species in mountain forest ecosystems of Gorski Kotar, Croatia

    International Nuclear Information System (INIS)

    Nikica Sprem; Ivan Babic; Domagoj Barisic; Delko Barisic

    2013-01-01

    The aim of this study was to investigate 137 Cs and 40 K load in large mammal game species in the mountain forest region of Gorski Kotar in Croatia approximately a quarter of century after the Chernobyl accident. 137 Cs and 40 K activity were determined by the gamma-spectrometric method in 49 meat samples of five large game species: brown bear (Ursus arctos), wild boar (Sus scrofa), roe deer (Capreolus capreolus), red deer (Cervus elaphus), and chamois (Rupicapra rupicapra). The results indicated that herbivore game species (roe deer, red deer and chamois) show significantly lower 137 Cs concentrations than omnivore species (brown bear, wild boar), thereby confirming the hypothesis that different dietary strategy impact caesium concentrations in meat. The measured caesium load in brown bear meat was in the range of two orders of magnitude, while caesium load in wild boar meat was found in the range of one order of magnitude. The estimated effective equivalent dose showed that uptake of the highest caesium doses would be from consumption of omnivore species meat, while much lower doses could be taken in with the consumption of meat from herbivore species. (author)

  8. Measurement of radon concentration in Taiz city dwellings-yemen

    International Nuclear Information System (INIS)

    Ali, Taher M.; Ahmed, Hayel A.; Ismail, Rokhsana M.

    2001-01-01

    Radon gas considered being a high part of natural radiation background. Emitting alpha particles; radon daughters may be deposited into the lungs and cause health hazards. For this reason, estimation of radon levels in dwellings was done in many countries. In our country, Radon group in the Department of physics, University of Aden has been studied radon level in Aden dwelling. The present study is about the radon level in Taiz City - Yemen. Passive diffusion dosimeters containing (SSNTD s ) Cr - 39 detectors were used in the present work. 125 dosimeters were distributed into dwellings of ten regions in Taiz City. Results obtained show that Rn 222 levels vary between 4 Bq/m 3 and 99 Bq/m 3 . The average concentration in Al-Hasseb district is 23 Bq/m 3 and in Algumhuri hospital district is 53 Bq/m 3 . In other regions it varies between the two values. Whereas the general average in the Taiz City is 34 Bq/m 3 . (author)

  9. Is lowering reducing sugars concentration in French fries an effective measure to reduce acrylamide concentration in food service establishments?

    Science.gov (United States)

    Sanny, M; Jinap, S; Bakker, E J; van Boekel, M A J S; Luning, P A

    2012-12-01

    The objective of this study was to obtain insight into the actual effectiveness of lowering reducing sugars concentration in par-fried potato strips on the concentration and variation of acrylamide in French fries prepared in real-life situations in food service establishments. Acrylamide, frying time, frying temperature, and reducing sugars were measured and characteristics of fryers were recorded. Data showed that the use of par-fried potato strips with lower concentrations of reducing sugars than the commonly used potato strips was an effective measure to reduce acrylamide concentrations in French fries prepared under standardised frying conditions. However, there was still large variation in the acrylamide concentrations in French fries, although the variation in reducing sugars concentrations in low and normal types of par-fried potato strips was very small and the frying conditions were similar. Factors that could affect the temperature-time profile of frying oil were discussed, such as setting a lower frying temperature at the end than at the start of frying, product/oil ratio and thawing practice. These need to be controlled in daily practice to reduce variation in acrylamide. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Concentration measurements of biodiesel in engine oil and in diesel fuel

    International Nuclear Information System (INIS)

    Mäder, A; Eskiner, M; Burger, C; Rossner, M; Krahl, J; Ruck, W

    2012-01-01

    This work comprised a method for concentration measurements of biodiesel in engine oil as well as biodiesel in diesel fuel by a measurement of the permittivity of the mixture at a frequency range from 100 Hz to 20 kHz. For this purpose a special designed measurement cell with high sensitivity was designed. The results for the concentration measurements of biodiesel in the engine oil and diesel fuel shows linearity to the measurement cell signal for the concentration of biodiesel in the engine oil between 0.5% Vol. to 10% Vol. and for biodiesel in the diesel fuel between 0% Vol. to 100% Vol. The method to measure the concentration of biodiesel in the engine oil or the concentration of biodiesel in the diesel fuel is very accurate and low concentration of about 0.5% Vol. biodiesel in engine oil or in diesel fuel can be measured with high accuracy.

  11. A high precision method for quantitative measurements of reactive oxygen species in frozen biopsies.

    Directory of Open Access Journals (Sweden)

    Kirsti Berg

    Full Text Available OBJECTIVE: An electron paramagnetic resonance (EPR technique using the spin probe cyclic hydroxylamine 1-hydroxy-3-methoxycarbonyl-2,2,5,5-tetramethylpyrrolidine (CMH was introduced as a versatile method for high precision quantification of reactive oxygen species, including the superoxide radical in frozen biological samples such as cell suspensions, blood or biopsies. MATERIALS AND METHODS: Loss of measurement precision and accuracy due to variations in sample size and shape were minimized by assembling the sample in a well-defined volume. Measurement was carried out at low temperature (150 K using a nitrogen flow Dewar. The signal intensity was measured from the EPR 1st derivative amplitude, and related to a sample, 3-carboxy-proxyl (CP• with known spin concentration. RESULTS: The absolute spin concentration could be quantified with a precision and accuracy better than ±10 µM (k = 1. The spin concentration of samples stored at -80°C could be reproduced after 6 months of storage well within the same error estimate. CONCLUSION: The absolute spin concentration in wet biological samples such as biopsies, water solutions and cell cultures could be quantified with higher precision and accuracy than normally achievable using common techniques such as flat cells, tissue cells and various capillary tubes. In addition; biological samples could be collected and stored for future incubation with spin probe, and also further stored up to at least six months before EPR analysis, without loss of signal intensity. This opens for the possibility to store and transport incubated biological samples with known accuracy of the spin concentration over time.

  12. The measurement of radon concentration of soil in a civil construction site

    International Nuclear Information System (INIS)

    Liu Hanbin; Fan Guang

    2004-01-01

    Radon is one of radioactive resources which do harm to human body. Therefore, its concentration in the soil should be measured before the civil construction works. Code for Indoor Environmental Pollution Control of Civil Building Engineering (GB50325-2001) is the main norm used for soil radon concentration measurement. By using FD-3017 RaA radon measuring equipment, the soil radon concentration in a civil building engineering site has been measured, the result shows that the concentration is lower than the regional average value, radon protective measures should not be installed in that site. (authors)

  13. System for measuring of air concentration in air-steam mixture during the transients

    International Nuclear Information System (INIS)

    Gorbenko, Gennady A.; Gakal, Pavlo G.; Epifanov, Konstantin S.; Osokin, Gennady V.; Smirnov, Sergey V.

    2006-01-01

    Description of system for air concentration measuring in air-steam mixture during the transients is represented. Air concentration measuring is based on discrete sampling method. The measuring system consists of sampler, transport pipeline, distributor and six measuring vessels. From the sampler air-steam mixture comes to distributor through transport pipeline and fills consecutively the measuring vessels. The true air concentration in place of measurement was defined based on measured air concentration in samples taken from measuring vessels. For this purpose, the mathematical model of transients in measuring system was developed. Air concentration transient in air-steam mixture in place of measurement was described in mathematical model by air concentration time-dependent function. The function parameters were defined based on air concentration measured in samples taken from measuring vessels. Estimated error of air concentration identification was about 10%. Measuring system was used in experiments on EREC BKV-213 test facility intended for testing of VVER-440/V-213 reactor barbotage-vacuum system

  14. Influence of sulfur-bearing polyatomic species on high precision measurements of Cu isotopic composition

    Science.gov (United States)

    Pribil, M.J.; Wanty, R.B.; Ridley, W.I.; Borrok, D.M.

    2010-01-01

    An increased interest in high precision Cu isotope ratio measurements using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has developed recently for various natural geologic systems and environmental applications, these typically contain high concentrations of sulfur, particularly in the form of sulfate (SO42-) and sulfide (S). For example, Cu, Fe, and Zn concentrations in acid mine drainage (AMD) can range from 100??g/L to greater than 50mg/L with sulfur species concentrations reaching greater than 1000mg/L. Routine separation of Cu, Fe and Zn from AMD, Cu-sulfide minerals and other geological matrices usually incorporates single anion exchange resin column chromatography for metal separation. During chromatographic separation, variable breakthrough of SO42- during anion exchange resin column chromatography into the Cu fractions was observed as a function of the initial sulfur to Cu ratio, column properties, and the sample matrix. SO42- present in the Cu fraction can form a polyatomic 32S-14N-16O-1H species causing a direct mass interference with 63Cu and producing artificially light ??65Cu values. Here we report the extent of the mass interference caused by SO42- breakthrough when measuring ??65Cu on natural samples and NIST SRM 976 Cu isotope spiked with SO42- after both single anion column chromatography and double anion column chromatography. A set of five 100??g/L Cu SRM 976 samples spiked with 500mg/L SO42- resulted in an average ??65Cu of -3.50?????5.42??? following single anion column separation with variable SO42- breakthrough but an average concentration of 770??g/L. Following double anion column separation, the average SO42-concentration of 13??g/L resulted in better precision and accuracy for the measured ??65Cu value of 0.01?????0.02??? relative to the expected 0??? for SRM 976. We conclude that attention to SO42- breakthrough on sulfur-rich samples is necessary for accurate and precise measurements of ??65Cu and may require

  15. [Relationship among the Oxygen Concentration, Reactive Oxygen Species and the Biological Characteristics of Mouse Bone Marrow Hematopoietic Stem Cells].

    Science.gov (United States)

    Ren, Si-Hua; He, Yu-Xin; Ma, Yi-Ran; Jin, Jing-Chun; Kang, Dan

    2016-02-01

    To investigate the effects of oxygen concentration and reactive oxygen species (ROS) on the biological characteristics of hematopoietic stem cells (HSC) and to analyzed the relationship among the oxygen concentration, ROS and the biological characteristics of mouse HSC through simulation of oxygen environment experienced by PB HSC during transplantation. The detection of reactive oxygen species (ROS), in vitro amplification, directional differentiation (BFU-E, CFU-GM, CFU-Mix), homing of adhesion molecules (CXCR4, CD44, VLA4, VLA5, P-selectin), migration rate, CFU-S of NOD/SCID mice irradiated with sublethal dose were performed to study the effect of oxgen concentration and reactive oxygen species on the biological characteristics of mouse BM-HSC and the relationship among them. The oxygen concentrations lower than normal oxygen concentration (especially hypoxic oxygen environment) could reduce ROS level and amplify more Lin(-) c-kit(+) Sca-1(+) BM HSC, which was more helpful to the growth of various colonies (BFU-E, CFU-GM, CFU-Mix) and to maintain the migratory ability of HSC, thus promoting CFU-S growth significantly after the transplantation of HSC in NOD/SCID mice irradiated by a sublethal dose. BM HSC exposed to oxygen environments of normal, inconstant oxygen level and strenuously thanging of oxygen concentration could result in higher level of ROS, at the same time, the above-mentioned features and functional indicators were relatively lower. The ROS levels of BM HSC in PB HSCT are closely related to the concentrations and stability of oxygen surrounding the cells. High oxygen concentration results in an high level of ROS, which is not helpful to maintain the biological characteristics of BM HSC. Before transplantation and in vitro amplification, the application of antioxidancs and constant oxygen level environments may be beneficial for transplantation of BMMSC.

  16. DGT measurement of dissolved aluminum species in waters

    DEFF Research Database (Denmark)

    Panther, Jared G.; Bennett, William W.; Teasdale, Peter R.

    2012-01-01

    Aluminum is acutely toxic, and elevated concentrations of dissolved Al can have detrimental effects on both terrestrial and aquatic ecosystems. Robust analytical methods that can determine environmentally relevant Al fractions accurately and efficiently are required by the environmental monitoring...

  17. Inverse correlation between reactive oxygen species in unwashed semen and sperm motion parameters as measured by a computer-assisted semen analyzer.

    Science.gov (United States)

    Takeshima, Teppei; Yumura, Yasushi; Yasuda, Kengo; Sanjo, Hiroyuki; Kuroda, Shinnosuke; Yamanaka, Hiroyuki; Iwasaki, Akira

    2017-01-01

    This study investigated the correlation between sperm motion parameters obtained by a computer-assisted semen analyzer and levels of reactive oxygen species in unwashed semen. In total, 847 patients, except for azoospermic patients were investigated. At the time of each patient's first consultation, semen parameters were measured using SMAS™ or CellSoft 3000™, and production of reactive oxygen species was measured using a computer-driven LKB Wallac Luminometer 1251 Analyzer. The patients were divided into two groups: reactive oxygen species - positive and negative. The semen parameters within each group were measured using one of the two computer-assisted semen analyzer systems and then compared. Correlations between reactive oxygen species levels and sperm motion parameters in semen from the reactive oxygen species - positive group were also investigated. Reactive oxygen species were detected in semen samples of 282 cases (33.3%). Sperm concentration (P semen damage sperm concentration, motility, and other sperm motion parameters.

  18. Assessment of radionuclide concentration in three crustaceans species of the bay of Bengal; Mesure de la concentration de radionucleides dans trois especes de crustaces du golfe du Bengale

    Energy Technology Data Exchange (ETDEWEB)

    Hasan, C.K.; Zafar, M. [Chittagong Univ., Institute of Marine Sciences (Bangladesh); Chowdhury, M.I.; Kamal, M. [Radioactivity Testing and Monitoring Laboratory, Bangladesh Atomic Energy Commission, Chittagong (Bangladesh)

    2006-10-15

    The natural ({sup 226}Ra, {sup 228}Th, {sup 232}Th and {sup 40}K) and anthropogenic ({sup 137}Cs) radionuclides concentrations in three crustaceans species (Penaeus monodon, Metapenaeus monoceros and Panulirus versicolor), collected from the bay of Bengal, were determined with an aim of assessing any internal radiation hazard due to consumption of the shell fishes and establishing a database for radioactivity levels of the species. Very low level of radioactivity was observed in all the species. The average activity of {sup 226}Ra observed in P. monodon was 1.21 {+-} 0.27 Bq kg{sup -1} fw; in M. monoceros was 0.70 {+-}0.08 Bq kg{sup -1} fw, and in Panulirus versicolor was 1.04 {+-} 0.09 Bq kg{sup -1} fw. The activity of {sup 232}Th observed in these species was 1.30 {+-} 0.37, 0.76 {+-} 0.34 and 1.32 {+-} 0.70 Bq kg{sup -1} fw, and {sup 228}Th was 0.55 {+-} 0.26, 0.31 {+-} 0.14 and 0.74 {+-} 0.22 Bq kg{sup -1} fw, respectively. The average activity of {sup 40}K observed in these species was 12.56 {+-} 1.18, 6.38 {+-}1.02 and 10.07 {+-} 1.52 Bq kg{sup -1} fw, respectively. The activity of radiocaesium ({sup 137}Cs) was below detection limit. The results indicate that the natural and artificial radionuclides observed in three crustaceans species are safe for human health. A significant relationship was observed between {sup 226}Ra and {sup 232}Th in both the P. monodon (r = 0.839, p {<=} 0.05, df = 4) and the Panulirus versicolor (r = 0.906, p {<=} 0.05, df = 4). (authors)

  19. Iodine uptake by spinach (Spinacia oleracea L.) plants grown in solution culture: effects of iodine species and solution concentrations.

    Science.gov (United States)

    Zhu, Y-G; Huang, Y-Z; Hu, Y; Liu, Y-X

    2003-04-01

    A hydroponic experiment was carried out to investigate the effects of iodine species and solution concentrations on iodine uptake by spinach (Spinacia oleracea L.). Five iodine concentrations (0, 1, 10, 50 and 100 microM) for iodate (IO(3)(-)) and iodide (I(-)) were used. Results show that higher concentrations of I(-) (> or =10 microM) had some detrimental effect on plant growth, while IO(3)(-) had little effect on the biomass production of spinach plants. Increases in iodine concentration in the growth solution significantly enhanced I concentrations in plant tissues. The detrimental effect of I(-) on plant growth was probably due to the excessively high accumulation of I in plant tissues. The solution-to-spinach leaf transfer factors (TF(leaf), fresh weight basis) for plants treated with iodide were between 14.2 and 20.7 at different solution concentrations of iodide; TF(leaf) for plants treated with iodate decreased gradually from 23.7 to 2.2 with increasing solution concentrations of iodate. The distribution coefficients (DCs) of I between leaves and roots were constantly higher for plants treated with iodate than those treated with iodide. DCs for plants treated with iodide increased with increasing solution concentrations of iodide, while DCs for plants treated with iodate (around 5.5) were similar across the range of solution concentrations of iodate used in this experiment. The implications of iodine accumulation in leafy vegetables in human iodine nutrition are also discussed. Copyright 2002 Elsevier Science Ltd.

  20. Photosynthesis of C3 and C4 Species in Response to Increased CO2 Concentration and Drought Stress

    Directory of Open Access Journals (Sweden)

    HAMIM

    2005-12-01

    Full Text Available Photosynthetic gas exchange in response to increased carbon dioxide concentration ([CO2] and drought stress of two C3 (wheat and kale and two C4 species (Echinochloa crusgallii and Amaranthus caudatus were analysed. Plants were grown in controlled growth chambers with ambient (350 μmol mol−1 and doubled ambient [CO2]. Drought was given by withholding water until the plants severely wilted, whereas the control plants were watered daily. Even though stomatal conductance (Gs of C4 species either under ambient or double [CO2] was lower than those in C3, doubled [CO2] decreased Gs of all species under well watered conditions. As a result, the plants grown under doubled [CO2] transpired less water than those grown under ambient [CO2]. Photosynthesis (Pn of the C4 species was sustained during moderate drought when those of the C3 species decreased significantly. Doubled [CO2] increased photosynthesis of C3 but not of C4 species. Increased [CO2] was only able to delay Pn reduction of all species due to the drought, but not remove it completely. The positive effects of increased [CO2] during moderate drought and the disappearance of it under severe drought suggesting that metabolic effect may limit photosynthesis under severe drought.

  1. Photosynthesis of C3 and C4 Species in Response to Increased CO2 Concentration and Drought Stress

    Directory of Open Access Journals (Sweden)

    HAMIM

    2005-12-01

    Full Text Available Photosynthetic gas exchange in response to increased carbon dioxide concentration ([CO2] and drought stress of two C3 (wheat and kale and two C4 species (Echinochloa crusgallii and Amaranthus caudatus were analysed. Plants were grown in controlled growth chambers with ambient (350 mol mol-1 and doubled ambient [CO2]. Drought was given by withholding water until the plants severely wilted, whereas the control plants were watered daily. Even though stomatal conductance (Gs of C4 species either under ambient or double [CO2] was lower than those in C3, doubled [CO2] decreased Gs of all species under well watered conditions. As a result, the plants grown under doubled [CO2] transpired less water than those grown under ambient [CO2]. Photosynthesis (Pn of the C4 species was sustained during moderate drought when those of the C3 species decreased significantly. Doubled [CO2] increased photosynthesis of C3 but not of C4 species. Increased [CO2] was only able to delay Pn reduction of all species due to the drought, but not remove it completely. The positive effects of increased [CO2] during moderate drought and the disappearance of it under severe drought suggesting that metabolic effect may limit photosynthesis under severe drought.

  2. Climate and Physiography Predict Mercury Concentrations in Game Fish Species in Quebec Lakes Better than Anthropogenic Disturbances.

    Science.gov (United States)

    Lucotte, Marc; Paquet, Serge; Moingt, Matthieu

    2016-05-01

    The fluctuations of mercury levels (Hg) in fish consumed by sport fishers in North-Eastern America depend upon a plethora of interrelated biological and abiological factors. To identify the dominant factors ultimately controlling fish Hg concentrations, we compiled mercury levels (Hg) during the 1976-2010 period in 90 large natural lakes in Quebec (Canada) for two major game species: northern pike (Esox lucius) and walleye (Sander vitreus). Our statistical analysis included 28 geographic information system variables and 15 climatic variables, including sulfate deposition. Higher winter temperatures explained 36% of the variability in higher walleye growth rates, in turn accounting for 54% of the variability in lower Hg concentrations. For northern pike, the dominance of a flat topography in the watershed explained 31% of the variability in lower Hg concentrations. Higher mean annual temperatures explained 27% of the variability in higher pike Hg concentrations. Pelagic versus littoral preferred habitats for walleye and pike respectively could explain the contrasted effect of temperature between the two species. Heavy logging could only explain 2% of the increase in walleye Hg concentrations. The influence of mining on fish Hg concentrations appeared to be masked by climatic effects.

  3. Variations in PCB concentrations between genders of six warmwater fish species in Lake Logan Martin, Alabama, USA.

    Science.gov (United States)

    Rypel, Andrew L; Findlay, Robert H; Mitchell, Justin B; Bayne, David R

    2007-08-01

    We collected and analyzed 955 individual fish (six species) for sexual differences in PCB bioaccumulations from a southeastern, USA reservoir. Using 2-way ANCOVAs, we found significant differences in fillet PCB concentrations between sexes for channel catfish (Ictalurus punctatus), largemouth bass (Micropterus salmoides) and spotted bass (Micropterus punctulatus). Striped bass (Morone saxatilus), black crappie (Pomoxis nigromaculatus) and freshwater drum (Aplodinotus grunniens) did not display differences between sexes in PCB concentrations. We suspect that sexual differences may be due to biological differences in reproduction, relative motility and lipid deposition. For one species (striped bass), sexual differences in PCB concentrations were inconsistent with a study in the Hudson River suggesting that sexual differences in bioaccumulations can change across ecosystems. Two species which did show sexual differences, largemouth bass and channel catfish, are often chosen as representative species (e.g., "piscivore" and "benthivore") in contaminant monitoring in many USA states indicating human consumption and risk management decisions would be improved if an equal number of male and female fish were included in composite PCBs analysis. This could reduce variability in fish PCBs data from which consumption advisories are based.

  4. Growth and {delta}{sup 13}C responses to increasing atmospheric carbon dioxide concentrations for several crop species

    Energy Technology Data Exchange (ETDEWEB)

    Hanba, Y.T.; Wada, E. [Center for Ecological Research, Kyoto University, Kyoto (Japan); Osaki, M.; Nakamura, T. [Faculty of Agriculture, Hokkaido University, Hokkaido (Japan)

    1996-04-01

    The responses of plant growth and carbon isotope discrimination ({Delta}) to elevated atmospheric CO{sub 2} concentrations for several crop species (lettuce: Lactuca sativa L.; corn: Zea Mays L. var. P3540, wheat: Triticum aestivum L. var Haruyutaka; and soybean: Glycine Max (L). Merr. var. Kitamusume) were investigated. Shoot relative growth rate was used to indicate plant growth, and {delta}{sup 13}C value of leaf materials in corn (C4 species) was used to calculate {Delta} for C3 species. Plant growth was stimulated by enriched CO{sub 2}, while {Delta} remained almost constant as CO{sub 2} concentration changed. {Delta} showed interspecific difference, and the plant species of larger {Delta} had larger relative growth rates. Relative growth rates of the plants of larger {Delta} were stimulated by CO{sub 2} enrichment more than those of the plants of smaller {Delta}. We propose that plant {Delta} could be a possible parameter to assess the interspecific difference of plant response to the increasing atmospheric CO{sub 2} concentrations. 3 figs., 2 tabs., 25 refs.

  5. 40 CFR 761.316 - Interpreting PCB concentration measurements resulting from this sampling scheme.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Interpreting PCB concentration... § 761.79(b)(3) § 761.316 Interpreting PCB concentration measurements resulting from this sampling... composite is 20 µg/100 cm2, then the entire 9.5 square meters has a PCB surface concentration of 20 µg/100...

  6. Growth measurement of some amylolytic bacillus species in three media

    International Nuclear Information System (INIS)

    Ajayi, A.O.

    2009-01-01

    Study of the growth pattern of some Bacillus species on starchy substrates showed that the metabolic activity affected the enzymatic activity. B. subtilis (WBS), B. licheniformis (WBL) and B. coagulans (MBC) generally had higher growth rate. B. circulans (SBC) and B. coagulans (WBC) had higher growth on cornstarch medium with corresponding higher beta-amylase production as compared to other strains such as B. polymyxa. Ten of the 13 Bacillus species studied had better performance on cornstarch than on soluble starch except B. macerans (MBM), B. macerans (SMB2) and B. subtilis (WBS). The enzyme production ranged from 0.022 unit/cfu x 102 to 0.912 unit/cfu x 102 on cornstarch and 0.01 unit/cfu x 102 to 0.693 unit/cfu x 102 on soluble starch. Relatively higher a-amylase activity was observed in B. subtilis, B. licheniformis, B. macerans and B. circulans (WBC1). (author)

  7. LITGS: a new technique for single shot temperature and fuel concentration measurements in turbulent combusting environments

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, Roberta; Giorgi, M. [ENEA, Centro Ricerche Frascati, Frascati, RM (Italy). Dipt. Innovazione; De Risi, A.; Laforgia, D. [Lecce Univ., Lecce (Italy). Dipt. di Ingegneria dell' Innovazione

    1999-07-01

    In the present study the possibility to apply time resolved Laser Induced Thermal Grating Spectroscopy (LITGS) to detect fuel concentration and temperature in mixtures and flames at atmospheric pressure or higher is investigated. The resonant IR single photon absorption of two short pulse pump beams is used to initially generate a population grating, decaying into a thermal grating due to relaxation processes in the gas mixture. The thermal grating evolution is followed by monitoring the scattered signal of a cw visible probe beam after the end of the pump pulse. The use of the IR optical transition of diesel fuel assured a high species selectivity and a negligible influence of the visible emission background due to the presence of electronically excited species in flames. Fuel concentration and temperature measurements in a pressurized cell, with pressure ranging between 0.1 an 1.5 MPa, and in a diffusion turbulent flame generated by a burner feed with diesel fuel operating at atmospheric pressure are presented. The experimental investigation shows that LITGS signal increase linearly with gas density. This characteristic makes LITGS a very interesting technique for fuel distribution and temperature measurements in hostile (high-pressure and turbulent flow) environments. Detection limit for diesel fuel at atmospheric pressure is found to be about 40 ppm and it decreases with the increase of the pressure. The low detection limit which can be reached makes this technique suitable also for monitoring minor species and radicals. [Italian] Nel presente studio si investiga la possibilita' di applicare la tecnica LITGS (Laser Induced Thermal Grating Spectroscopy) per misurare la concentrazione e la temperatura di carburante in miscele e fiamme a pressiona atmosferica o superiore. L'assorbimento risonante di un singolo fotone IR proveniente da uno dei due laser impulsati di pompa e' utilizzato per generare inizialmente un reticolo di popolazione, che decade

  8. Airborne plutonium and americium concentrations measured from the top of Rattlesnake Mountain

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1979-01-01

    Airborne plutonium-239+240 and americium-241 blowing from offsite was measured in an initial experiment at the top of Rattlesnake Mountain. Average airborne concentration measured was similar to fallout concentrations. Airborne plutonium concentrations were independent of wind speed for seven wind speed increments between 0.5 and 31 m/sec. In contrast the airborne americium concentration was a minimum at a wind speed of approximately 7 m/sec. Similarly, the airborne solids concentration in μg/m 3 was a minimum at an intermediate wind speed increment of 7 to 11 m/sec

  9. Measuring management success for protected species: Looking beyond biological outcomes

    Directory of Open Access Journals (Sweden)

    Kathryn D Bisack

    2016-05-01

    Full Text Available The complexity of the ocean ecosystem, including the human component, is such that a single fishery may require multiple policy instruments to support recovery and conservation of protected species, in addition to those for fisheries management. As regulations multiply, the need for retrospective analysis and evaluation grows in order to inform future policy. To accurately evaluate policy instruments, clear objectives and their link to outcomes are necessary, as well as identifying criteria to evaluate outcomes. The Northeast United States sink gillnet groundfish fishery provides a case study of the complexity of regulations and policy instruments implemented under the Marine Mammal Protection Act and the Endangered Species Act to address bycatch of marine mammals. The case study illustrates a range of possible objectives for the policy instruments including biological, economic, social-normative and longevity factors. We highlight links between possible objectives, outcomes and criteria for the four factors, as well as areas for consideration when undertaking ex-post analyses. To support learning from past actions, we call for a coordinated effort involving multiple disciplines and jurisdictions to undertake retrospective analyses and evaluations of key groups of policy instruments used for protected species.

  10. Measurements of neonatal bilirubin and albumin concentrations : a need for improvement and quality control

    NARCIS (Netherlands)

    van Imhoff, Deirdre E.; Dijk, Peter H.; Weykamp, Cas W.; Cobbaert, Christa M.; Hulzebos, Christian V.

    Accurate and precise bilirubin and albumin measurements are essential for proper management of jaundiced neonates. Data hereon are lacking for Dutch laboratories. We aimed to determine variability of measurements of bilirubin and albumin concentrations typical for (preterm) neonates. Aqueous, human

  11. Measurements of neonatal bilirubin and albumin concentrations: a need for improvement and quality control

    NARCIS (Netherlands)

    Imhoff, D.E. van; Dijk, P.H.; Weykamp, C.W.; Cobbaert, C.M.; Hulzebos, C.V.; Liem, K.D.; et al.,

    2011-01-01

    Accurate and precise bilirubin and albumin measurements are essential for proper management of jaundiced neonates. Data hereon are lacking for Dutch laboratories. We aimed to determine variability of measurements of bilirubin and albumin concentrations typical for (preterm) neonates. Aqueous, human

  12. Study on the concentration and seasonal variation of inorganic elements in 35 species of marine algae

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Yan, X.J.

    1998-01-01

    The concentrations of five major and 28 trace elements in 35 marine algae collected along the coast of China were determined by instrumental neutron activation analysis. The concentrations of halogens, rare earth elements and many transition metal elements in marine algae are remarkably higher than...... those in terrestrial plants. The concentration factors for 31 elements in all collected algae were calculated, those for tri- and tetra-valent elements were higher than those of the mono- and di-valent elements in marine algae. The biogeochemical characteristics of inorganic elements in marine algae...

  13. Quantitative Measurements of Electronically Excited CH Concentration in Normal Gravity and Microgravity Coflow Laminar Diffusion Flames

    Science.gov (United States)

    Giassi, D.; Cao, S.; Stocker, D. P.; Takahashi, F.; Bennett, B. A. V.; Smooke, M. D.; Long, M. B.

    2015-01-01

    With the conclusion of the SLICE campaign aboard the ISS in 2012, a large amount of data was made available for the analysis of the effect of microgravity on laminar coflow diffusion flames. Previous work focused on the study of sooty flames in microgravity as well as the ability of numerical models to predict its formation in a simplified buoyancy-free environment. The current work shifts the investigation to soot-free flames, putting an emphasis on the chemiluminescence emission from electronically excited CH (CH*). This radical species is of significant interest in combustion studies: it has been shown that the electronically excited CH spatial distribution is indicative of the flame front position and, given the relatively simple diagnostic involved with its measurement, several works have been done trying to understand the ability of electronically excited CH chemiluminescence to predict the total and local flame heat release rate. In this work, a subset of the SLICE nitrogen-diluted methane flames has been considered, and the effect of fuel and coflow velocity on electronically excited CH concentration is discussed and compared with both normal gravity results and numerical simulations. Experimentally, the spectral characterization of the DSLR color camera used to acquire the flame images allowed the signal collected by the blue channel to be considered representative of the electronically excited CH emission centered around 431 nm. Due to the axisymmetric flame structure, an Abel deconvolution of the line-of-sight chemiluminescence was used to obtain the radial intensity profile and, thanks to an absolute light intensity calibration, a quantification of the electronically excited CH concentration was possible. Results show that, in microgravity, the maximum flame electronically excited CH concentration increases with the coflow velocity, but it is weakly dependent on the fuel velocity; normal gravity flames, if not lifted, tend to follow the same trend

  14. Quantitative Measurements of CH* Concentration in Normal Gravity and Microgravity Coflow Laminar Diffusion Flames

    Science.gov (United States)

    Giassi, D.; Cao, S.; Stocker, D. P.; Takahashi, F.; Bennett, B. A.; Smooke, M. D.; Long, M. B.

    2015-01-01

    With the conclusion of the SLICE campaign aboard the ISS in 2012, a large amount of data was made available for the analysis of the effect of microgravity on laminar coflow diffusion flames. Previous work focused on the study of sooty flames in microgravity as well as the ability of numerical models to predict its formation in a simplified buoyancy-free environment. The current work shifts the investigation to soot-free flames, putting an emphasis on the chemiluminescence emission from electronically excited CH (CH*). This radical species is of significant interest in combustion studies: it has been shown that the CH* spatial distribution is indicative of the flame front position and, given the relatively simple diagnostic involved with its measurement, several works have been done trying to understand the ability of CH* chemiluminescence to predict the total and local flame heat release rate. In this work, a subset of the SLICE nitrogen-diluted methane flames has been considered, and the effect of fuel and coflow velocity on CH* concentration is discussed and compared with both normal gravity results and numerical simulations. Experimentally, the spectral characterization of the DSLR color camera used to acquire the flame images allowed the signal collected by the blue channel to be considered representative of the CH* emission centered around 431 nm. Due to the axisymmetric flame structure, an Abel deconvolution of the line-of-sight chemiluminescence was used to obtain the radial intensity profile and, thanks to an absolute light intensity calibration, a quantification of the CH* concentration was possible. Results show that, in microgravity, the maximum flame CH* concentration increases with the coflow velocity, but it is weakly dependent on the fuel velocity; normal gravity flames, if not lifted, tend to follow the same trend, albeit with different peak concentrations. Comparisons with numerical simulations display reasonably good agreement between measured and

  15. Automatic measuring device for atomic oxygen concentrations (1962); Dispositif de mesure automatique de concentrations d'oxygene atomique (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J; Deiss, M; Mercier, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    Within the framework of the activities of the Autonomous Reactor Electronics Section we have developed a device, which renders automatic one type of measurement carried out in the Physical Chemistry Department at the Saclay Research Centre. We define here: - the physico-chemical principle of the apparatus which is adapted to the measurement of atomic oxygen concentrations; - the physical principle of the automatic measurement; - the properties, performance, constitution, use and maintenance of the automatic measurement device. It is concluded that the principle of the automatic device, whose tests have confirmed the estimation of the theoretical performance, could usefully be adapted to other types of measurement. (authors) [French] Dans le cadre des activites de la Section Autonome d'Electronique des Reacteurs, il a ete realise et mis au point un dispositif permettant de rendre automatique un type de mesures effectuees au Departement de Physico-Chimie du C.E.N. SACLAY. On definit ici: - le principe physico-chimique de l'appareillage, adapte a la mesure de concentrations de l'oxygene atomique; - le principe physique de la mesure automatique; - les qualites, performances, constitution, utilisation, et maintenance du dispositif de mesure automatique. Il est porte en conclusion, que le principe du dispositif automatique realise, dont les essais ont sensiblement confirme l'evaluation des performances theoriques, pourrait etre utilement adapte a d'autres types de mesures courantes. (auteurs)

  16. Estimating Concentrations of Road-Salt Constituents in Highway-Runoff from Measurements of Specific Conductance

    Science.gov (United States)

    Granato, Gregory E.; Smith, Kirk P.

    1999-01-01

    Discrete or composite samples of highway runoff may not adequately represent in-storm water-quality fluctuations because continuous records of water stage, specific conductance, pH, and temperature of the runoff indicate that these properties fluctuate substantially during a storm. Continuous records of water-quality properties can be used to maximize the information obtained about the stormwater runoff system being studied and can provide the context needed to interpret analyses of water samples. Concentrations of the road-salt constituents calcium, sodium, and chloride in highway runoff were estimated from theoretical and empirical relations between specific conductance and the concentrations of these ions. These relations were examined using the analysis of 233 highwayrunoff samples collected from August 1988 through March 1995 at four highway-drainage monitoring stations along State Route 25 in southeastern Massachusetts. Theoretically, the specific conductance of a water sample is the sum of the individual conductances attributed to each ionic species in solution-the product of the concentrations of each ion in milliequivalents per liter (meq/L) multiplied by the equivalent ionic conductance at infinite dilution-thereby establishing the principle of superposition. Superposition provides an estimate of actual specific conductance that is within measurement error throughout the conductance range of many natural waters, with errors of less than ?5 percent below 1,000 microsiemens per centimeter (?S/cm) and ?10 percent between 1,000 and 4,000 ?S/cm if all major ionic constituents are accounted for. A semi-empirical method (adjusted superposition) was used to adjust for concentration effects-superposition-method prediction errors at high and low concentrations-and to relate measured specific conductance to that calculated using superposition. The adjusted superposition method, which was developed to interpret the State Route 25 highway-runoff records, accounts for

  17. Relationships of mercury concentrations across tissue types, muscle regions and fins for two shark species

    KAUST Repository

    O'Bryhim, Jason R.; Adams, Douglas H.; Spaet, Julia L.; Mills, Gary; Lance, Stacey L.

    2017-01-01

    mercury (THg) concentrations from eight muscle regions, four fins (first dorsal, left and right pectorals, caudal-from both the inner core and trailing margin of each fin), and five internal organs (liver, kidney, spleen, heart, epigonal organ) from two

  18. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII...

  19. Determination of deuterium concentrations in JET plasmas from fusion reaction rate measurements

    International Nuclear Information System (INIS)

    Jarvis, O.N.; Balet, B.; Cordey, J.G.; Morgan, P.D.; Sadler, G.; Belle, P. van; Conroy, S.; Elevant, T.

    1989-01-01

    The concentration of deuterium in the central regions of JET plasmas, expressed as a fraction of the electron concentration (n d /n e ), has been determined using four different methods involving neutron detection. These measurements are found to be consistent and agree within experimental errors with values deduced from Z eff measurements using visible bremsstrahlung radiation. (author) 11 refs., 1 fig., 1 tab

  20. Species distributions, quantum theory, and the enhancement of biodiversity measures

    DEFF Research Database (Denmark)

    Real, Raimundo; Barbosa, A. Márcia; Bull, Joseph William

    2017-01-01

    Species distributions are typically represented by records of their observed occurrence at a given spatial and temporal scale. Such records are inevitably incomplete and contingent on the spatial–temporal circumstances under which the observations were made. Moreover, organisms may respond...... biodiversity”. We show how conceptualizing species’ distributions in this way could help overcome important weaknesses in current biodiversity metrics, both in theory and by using a worked case study of mammal distributions in Spain over the last decade. We propose that considerable theoretical advances could...

  1. Systematic Approach to Calculate the Concentration of Chemical Species in Multi-Equilibrium Problems

    Science.gov (United States)

    Baeza-Baeza, Juan Jose; Garcia-Alvarez-Coque, Maria Celia

    2011-01-01

    A general systematic approach is proposed for the numerical calculation of multi-equilibrium problems. The approach involves several steps: (i) the establishment of balances involving the chemical species in solution (e.g., mass balances, charge balance, and stoichiometric balance for the reaction products), (ii) the selection of the unknowns (the…

  2. Mesocosm validation of the marine No Effect Concentration of dissolved copper derived from a species sensitivity distribution.

    Science.gov (United States)

    Foekema, E M; Kaag, N H B M; Kramer, K J M; Long, K

    2015-07-15

    The Predicted No Effect Concentration (PNEC) for dissolved copper based on the species sensitivity distribution (SSD) of 24 marine single species tests was validated in marine mesocosms. To achieve this, the impact of actively maintained concentrations of dissolved copper on a marine benthic and planktonic community was studied in 18 outdoor 4.6m(3) mesocosms. Five treatment levels, ranging from 2.9 to 31μg dissolved Cu/L, were created in triplicate and maintained for 82days. Clear effects were observed on gastropod and bivalve molluscs, phytoplankton, zooplankton, sponges and sessile algae. The most sensitive biological endpoints; reproduction success of the bivalve Cerastoderma edule, copepod population development and periphyton growth were significantly affected at concentrations of 9.9μg Cu/L and higher. The No Observed Effect Concentration (NOEC) derived from this study was 5.7μg dissolved Cu/L. Taking into account the DOC concentration of the mesocosm water this NOEC is comparable to the PNEC derived from the SSD. Copyright © 2015. Published by Elsevier B.V.

  3. Kinetic model for predicting the concentrations of active halogens species in chlorinated saline cooling waters. Final report

    International Nuclear Information System (INIS)

    Haag, W.R.; Lietzke, M.H.

    1981-08-01

    A kinetic model has been developed for describing the speciation of chlorine-produced oxidants in seawater as a function of time. The model is applicable under a broad variety of conditions, including all pH range, salinities, temperatures, ammonia concentrations, organic amine concentrations, and chlorine doses likely to be encountered during power plant cooling water chlorination. However, the effects of sunlight are not considered. The model can also be applied to freshwater and recirculating water systems with cooling towers. The results of the model agree with expectation, however, complete verification is not feasible at the present because analytical methods for some of the predicted species are lacking

  4. Kinetic model for predicting the concentrations of active halogens species in chlorinated saline cooling waters. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Haag, W.R.; Lietzke, M.H.

    1981-08-01

    A kinetic model has been developed for describing the speciation of chlorine-produced oxidants in seawater as a function of time. The model is applicable under a broad variety of conditions, including all pH range, salinities, temperatures, ammonia concentrations, organic amine concentrations, and chlorine doses likely to be encountered during power plant cooling water chlorination. However, the effects of sunlight are not considered. The model can also be applied to freshwater and recirculating water systems with cooling towers. The results of the model agree with expectation, however, complete verification is not feasible at the present because analytical methods for some of the predicted species are lacking.

  5. High concentration suspended sediment measurments using acontinuous fiber optic in-stream transmissometer

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Chris G.; Laycak, Danny T.; Hoppes, William; Tran,Nguyen T.; Shi, Frank G.

    2004-05-26

    Suspended sediment loads mobilized during high flow periods in rivers and streams are largely uncharacterized. In smaller and intermittent streams, a large storm may transport a majority of the annual sediment budget. Therefore monitoring techniques that can measure high suspended sediment concentrations at semi-continuous time intervals are needed. A Fiber optic In-stream Transmissometer (FIT) is presented for continuous measurement of high concentration suspended sediment in storm runoff. FIT performance and precision were demonstrated to be reasonably good for suspended sediment concentrations up to 10g/L. The FIT was compared to two commercially available turbidity devices and provided better precision and accuracy at both high and low concentrations. Both turbidity devices were unable to collect measurements at concentrations greater than 4 g/L. The FIT and turbidity measurements were sensitive to sediment particle size. Particle size dependence of transmittance and turbidity measurement poses the greatest problem for calibration to suspended sediment concentration. While the FIT was demonstrated to provide acceptable measurements of high suspended sediment concentrations, approaches to real-time suspended sediment detection need to address the particle size dependence in concentration measurements.

  6. Species-dependent adaptation of the cardiac Na+/K+ pump kinetics to the intracellular Na+ concentration.

    Science.gov (United States)

    Lewalle, Alexandre; Niederer, Steven A; Smith, Nicolas P

    2014-12-15

    The Na(+)/K(+) ATPase (NKA) plays a critical role in maintaining ionic homeostasis and dynamic function in cardiac myocytes, within both the in vivo cell and in silico models. Physiological conditions differ significantly between mammalian species. However, most existing formulations of NKA used to simulate cardiac function in computational models are derived from a broad range of experimental sources spanning many animal species. The resultant inability of these models to discern species-specific features is a significant obstacle to achieving a detailed quantitative and comparative understanding of physiological behaviour in different biological contexts. Here we present a framework for characterising the steady-state NKA current using a biophysical mechanistic model specifically designed to provide a mechanistic explanation of the NKA flux supported by self-consistent species-specific data. We thus compared NKA kinetics specific to guinea- pig and rat ventricular myocytes. We observe that the apparent binding affinity for sodium in the rat is significantly lower, whereas the overall pump cycle rate is doubled, in comparison to the guinea pig. This sensitivity of NKA to its regulatory substrates compensates for the differences in Na(+) concentrations between the cell types. NKA is thereby maintained within its dynamic range over a wide range of pacing frequencies in these two species, despite significant disparities in sodium concentration. Hence, by replacing a conventional generic NKA model with our rat-specific NKA formula into a whole-cell simulation, we have, for the first time, been able to accurately reproduce the action potential duration and the steady-state sodium concentration as functions of pacing frequency. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  7. Concentration of 137Cs by certain species of fresh water invertebrates

    International Nuclear Information System (INIS)

    Nilov, V.I.

    1983-01-01

    Results of experimental studies on 137 Cs accumulation by fresh-water invertebrates of various taxonomic groups are given. The invertebrate 137 Cs accumulative ability depends on the species belonging, age and sex of the animal. Radionuclide deposition by Cladocera depends on water temperature. Mollusc embryons need different quantities of cerium for their development. An appreciable role in 137 Cs extraction from fresh water is attributed to fry, adult Gammarus and Daphnia

  8. The response of three dominant Arctic copepod species to elevated CO2 concentrations and water temperatures

    OpenAIRE

    Hildebrandt, Nicole

    2014-01-01

    Ocean acidification (OA) and ocean warming are threatening marine life. Within the framework of the research project BIOACID, this thesis aims to provide a comprehensive overview on the sensitivity of the dominant Arctic calanoid copepod species Calanus finmarchicus, C. glacialis and C. hyperboreus to elevated pCO2 and temperatures. Controlled laboratory experiments have shown that subadult and adult Calanus life stages are rather robust to the direct effects of OA during both active and rest...

  9. Significance of radioelement concentration measurements made by airborne gamma-ray spectrometry over the Canadian Shield

    International Nuclear Information System (INIS)

    Charbonneau, B.W.; Killeen, P.G.; Carson, J.M.; Cameron, G.W.; Richardson, K.A.

    1976-01-01

    Results of airborne gamma-ray spectrometer surveys conducted by the Geological Survey of Canada are presented as maps contoured in units of radioelement and concentration ratios. These contoured values represent the average surface concentrations of the radioelements over areas of the order of several square kilometres. The relationship between this ''average surface concentration'' and the radioelement concentration in bedrock underlying the area depends on: (1) the percentage of outcrop; (2) the relation between overburden and bedrock radioelement concentration; (3) percentage of marshland or surface water in the area; (4) soil moisture; and (5) density of vegetation. More than 2500 portable gamma-ray spectrometer analyses of outcrop and overburden have been made in the Bancroft, Elliot Lake and Fort Smith areas of the Canadian Precambrian Shield. In the areas examined, the radioelement concentrations in glacial drift reflect the concentrations in the underlying bedrock. Rocks with near-crustal average contents of thorium, uranium and potassium are overlain by glacial drift having approximately the same concentrations. As the concentration in bedrock increases, the concentration in the local overburden also increases, but not to the same extent. In addition, in-situ gamma-ray spectrometry measurements were made at almost 1000 stations within the area of airborne surveys near Mont Laurier and Elliot Lake. These ground measurements were compared with the airborne measurements by averaging the values for all those ground stations located in the areas between each contour level on airborne maps. Radioelement concentrations in bedrock are considerably higher than corresponding airborne measurements, and this difference between bedrock and airborne values increases at higher radioelement concentrations. Radioelement concentrations in glacial drift are only slightly higher than airborne contour values for the same area. Airborne contour maps of the radioelement ratios

  10. Measurement of airborne concentrations of radon-220 daughter products by alpha-particle spectrometry

    International Nuclear Information System (INIS)

    Kerr, G.D.; Ryan, M.T.; Perdue, P.T.

    1978-01-01

    The decay of naturally occurring uranium-238 and thorium-232 produces radon-222 and radon-220 isotopes which can escape into the atmosphere. If these radon gases become concentrated in air, their daughter products may present an inhalation hazard to man. The airborne concentrations of radon-222 can usually be measured very accurately in the presence of normal airborne concentrations of radon-220 and its daughters. In contrast, the measurements of the airborne concentrations of radon-220 daughters are usually complicated by the presence of radon-222 and its daughters even at normally occurring airborne concentrations. The complications involved in these measurements can be overcome in most situations by using an alpha particle spectrometer to distinguish the activity of radon-222 daughters from that due to radon-220 daughters collected on a filter. A practical spectrometer for field measurements of alpha particle activity on a filter is discussed

  11. Next remarks to the knowledge of heavy metal concentrations in gravid tapeworm species parasitizing aquatic birds

    Czech Academy of Sciences Publication Activity Database

    Tenora, F.; Baruš, Vlastimil; Prokeš, Miroslav

    2002-01-01

    Roč. 39, č. 3 (2002), s. 143-148 ISSN 0440-6605 R&D Projects: GA ČR GA524/01/1314; GA AV ČR IAA6093104 Institutional research plan: CEZ:AV0Z6093917 Keywords : heavy metal concentrations * Cestoda * aquatic birds Subject RIV: EH - Ecology, Behaviour Impact factor: 0.646, year: 2002

  12. PM mass and elemental species concentration data for I-96 monitoring sites

    Data.gov (United States)

    U.S. Environmental Protection Agency — PM2.5 (fine) and PM10-2.5 (coarse) mass concentrations for monitoring sites located 10 m, 100 m and 300 m north of Interstate I-96 in Detroit, the water-soluble and...

  13. Functional diversity measures revealed impacts of non-native species and habitat degradation on species-poor freshwater fish assemblages.

    Science.gov (United States)

    Colin, Nicole; Villéger, Sébastien; Wilkes, Martin; de Sostoa, Adolfo; Maceda-Veiga, Alberto

    2018-06-01

    Trait-based ecology has been developed for decades to infer ecosystem responses to stressors based on the functional structure of communities, yet its value in species-poor systems is largely unknown. Here, we used an extensive dataset in a Spanish region highly prone to non-native fish invasions (15 catchments, N=389 sites) to assess for the first time how species-poor communities respond to large-scale environmental gradients using a taxonomic and functional trait-based approach in riverine fish. We examined total species richness and three functional trait-based indices available when many sites have ≤3 species (specialization, FSpe; originality, FOri and entropy, FEnt). We assessed the responses of these taxonomic and functional indices along gradients of altitude, water pollution, physical habitat degradation and non-native fish biomass. Whilst species richness was relatively sensitive to spatial effects, functional diversity indices were responsive across natural and anthropogenic gradients. All four diversity measures declined with altitude but this decline was modulated by physical habitat degradation (richness, FSpe and FEnt) and the non-native:total fish biomass ratio (FSpe and FOri) in ways that varied between indices. Furthermore, FSpe and FOri were significantly correlated with Total Nitrogen. Non-native fish were a major component of the taxonomic and functional structure of fish communities, raising concerns about potential misdiagnosis between invaded and environmentally-degraded river reaches. Such misdiagnosis was evident in a regional fish index widely used in official monitoring programs. We recommend the application of FSpe and FOri to extensive datasets from monitoring programs in order to generate valuable cross-system information about the impacts of non-native species and habitat degradation, even in species-poor systems. Scoring non-native species apart from habitat degradation in the indices used to determine ecosystem health is

  14. A new method to measure effective soil solution concentration predicts copper availability to plants.

    Science.gov (United States)

    Zhang, H; Zhao, F J; Sun, B; Davison, W; McGrath, S P

    2001-06-15

    Risk assessments of metal contaminated soils need to address metal bioavailability. To predict the bioavailability of metals to plants, it is necessary to understand both solution and solid phase supply processes in soils. In striving to find surrogate chemical measurements, scientists have focused either on soil solution chemistry, including free ion activities, or operationally defined fractions of metals. Here we introduce the new concept of effective concentration, CE, which includes both the soil solution concentration and an additional term, expressed as a concentration, that represents metal supplied from the solid phase. CE was measured using the technique of diffusive gradients in thin films (DGT) which, like a plant, locally lowers soil solution concentrations, inducing metal supply from the solid phase, as shown by a dynamic model of the DGT-soil system. Measurements of Cu as CE, soil solution concentration, by EDTA extraction and as free Cu2+ activity in soil solution were made on 29 different soils covering a large range of copper concentrations. Theywere compared to Cu concentrations in the plant material of Lepidium heterophyllum grown on the same soils. Plant concentrations were linearly related and highly correlated with CE but were more scattered and nonlinear with respect to free Cu2+ activity, EDTA extraction, or soil solution concentrations. These results demonstrate that the dominant supply processes in these soils are diffusion and labile metal release, which the DGT-soil system mimics. The quantity CE is shown to have promise as a quantitative measure of the bioavailable metal in soils.

  15. Continuous measurement of the radon concentration in water using electret ion chamber method

    International Nuclear Information System (INIS)

    Dua, S.K.; Hopke, P.K.

    1992-10-01

    A radon concentration of 300 pCi/L has been proposed by the US Environmental Protection Agency as a limit for radon dissolved in municipal drinking water supplies. There is therefore a need for a continuous monitor to insure that the daily average concentration does not exceed this limit. In order to calibrate the system, varying concentrations of radon in water have been generated by bubbling radon laden air through a dynamic flowthrough water system. The value of steady state concentration of radon in water from this system depends on the concentration of radon in air, the air bubbling rate, and the water flow rate. The measurement system has been designed and tested using a 1 L volume electret ion chamber to determine the radon in water. In this dynamic method, water flows directly through the electret ion chamber. Radon is released to the air and measured with the electret. A flow of air is maintained through the chamber to prevent the build-up of high radon concentrations and too rapid discharge of the electret. It was found that the system worked well when the air flow was induced by the application of suction. The concentration in the water was calculated from the measured concentration in air and water and air flow rates. Preliminary results suggest that the method has sufficient sensitivity to measure concentrations of radon in water with acceptable accuracy and precision

  16. Indoor and outdoor atmospheric fungal spores in the São Paulo metropolitan area (Brazil): species and numeric concentrations

    Science.gov (United States)

    Gonçalves, Fábio Luiz Teixeira; Bauer, Heidi; Cardoso, Maria Regina Alves; Pukinskas, Sandra; Matos, Dulcilena; Melhem, Márcia; Puxbaum, Hans

    2010-07-01

    The aim of this study was to estimate the indoor and outdoor concentrations of fungal spores in the Metropolitan Area of Sao Paulo (MASP), collected at different sites in winter/spring and summer seasons. The techniques adopted included cultivation (samples collected with impactors) and microscopic enumeration (samples collected with impingers). The overall results showed total concentrations of fungal spores as high as 36,000 per cubic meter, with a large proportion of non culturable spores (around 91% of the total). Penicillium sp. and Aspergillus sp. were the dominant species both indoors and outdoors, in all seasons tested, occurring in more than 30% of homes at very high concentrations of culturable airborne fungi [colony forming units(CFU) m-3]. There was no significant difference between indoor and outdoor concentrations. The total fungal spore concentration found in winter was 19% higher than that in summer. Heat and humidity were the main factors affecting fungal growth; however, a non-linear response to these factors was found. Thus, temperatures below 16°C and above 25°C caused a reduction in the concentration (CFU m-3) of airborne fungi, which fits with MASP climatalogy. The same pattern was observed for humidity, although not as clearly as with temperature given the usual high relative humidity (above 70%) in the study area. These results are relevant for public health interventions that aim to reduce respiratory morbidity among susceptible populations.

  17. Optical performance evaluation of a solar furnace by measuring the highly concentrated solar flux

    International Nuclear Information System (INIS)

    Lee, Hyunjin; Chai, Kwankyo; Kim, Jongkyu; Lee, Sangnam; Yoon, Hwanki; Yu, Changkyun; Kang, Yongheack

    2014-01-01

    We evaluated optical performance of a solar furnace in the KIER (Korea Institute of Energy Research) by measuring the highly concentrated solar flux with the flux mapping method. We presented and analyzed optical performance in terms of concentrated solar flux distribution and power distribution. We investigated concentration ratio, stagnation temperature, total power, and concentration accuracy with help of a modeling code based on the ray tracing method and thereby compared with other solar furnaces. We also discussed flux changes by shutter opening angles and by position adjustment of reflector facets. In the course of flux analysis, we provided a better understanding of reference flux measurement for calibration, reflectivity measurement with a portable reflectometer, shadowing area consideration for effective irradiation, as well as accuracy and repeatability of flux measurements. The results in the present study will help proper utilization of a solar furnace by facilitating comparison between flux measurements at different conditions and flux estimation during operation

  18. Modeling the distribution of colonial species to improve estimation of plankton concentration in ballast water

    Science.gov (United States)

    Rajakaruna, Harshana; VandenByllaardt, Julie; Kydd, Jocelyn; Bailey, Sarah

    2018-03-01

    The International Maritime Organization (IMO) has set limits on allowable plankton concentrations in ballast water discharge to minimize aquatic invasions globally. Previous guidance on ballast water sampling and compliance decision thresholds was based on the assumption that probability distributions of plankton are Poisson when spatially homogenous, or negative binomial when heterogeneous. We propose a hierarchical probability model, which incorporates distributions at the level of particles (i.e., discrete individuals plus colonies per unit volume) and also within particles (i.e., individuals per particle) to estimate the average plankton concentration in ballast water. We examined the performance of the models using data for plankton in the size class ≥ 10 μm and test ballast water compliance using the above models.

  19. Seasonal changes in Fe species and soluble Fe concentration in the atmosphere in the Northwest Pacific region based on the analysis of aerosols collected in Tsukuba, Japan

    Directory of Open Access Journals (Sweden)

    Y. Takahashi

    2013-08-01

    Full Text Available Atmospheric iron (Fe can be a significant source of nutrition for phytoplankton inhabiting remote oceans, which in turn has a large influence on the Earth's climate. The bioavailability of Fe in aerosols depends mainly on the fraction of soluble Fe (= [FeSol]/[FeTotal], where [FeSol] and [FeTotal] are the atmospheric concentrations of soluble and total Fe, respectively. However, the numerous factors affecting the soluble Fe fraction have not been fully understood. In this study, the Fe species, chemical composition, and soluble Fe concentrations in aerosols collected in Tsukuba, Japan were investigated over a year (nine samples from December 2002 to October 2003 to identify the factors affecting the amount of soluble Fe supplied into the ocean. The soluble Fe concentration in aerosols is correlated with those of sulfate and oxalate originated from anthropogenic sources, suggesting that soluble Fe is mainly derived from anthropogenic sources. Moreover, the soluble Fe concentration is also correlated with the enrichment factors of vanadium and nickel emitted by fossil fuel combustion. These results suggest that the degree of Fe dissolution is influenced by the magnitude of anthropogenic activity, such as fossil fuel combustion. X-ray absorption fine structure (XAFS spectroscopy was performed in order to identify the Fe species in aerosols. Fitting of XAFS spectra coupled with micro X-ray fluorescence analysis (μ-XRF showed the main Fe species in aerosols in Tsukuba to be illite, ferrihydrite, hornblende, and Fe(III sulfate. Moreover, the soluble Fe fraction in each sample measured by leaching experiments is closely correlated with the Fe(III sulfate fraction determined by the XAFS spectrum fitting, suggesting that Fe(III sulfate is the main soluble Fe in the ocean. Another possible factor that can control the amount of soluble Fe supplied into the ocean is the total Fe(III concentration in the atmosphere, which was high in spring due to the high

  20. Measurement of radon, thoron and their progeny concentrations in the dwellings of Pauri Garhwal, Uttarakhand, India

    International Nuclear Information System (INIS)

    Joshi, Veena; Bijalwan, Pramesh; Rawat, Jasbir; Yadav, Manjulata; Ramola, R.C.; Mishra, Rosaline

    2015-01-01

    It is well known that inhalation of radon, thoron and their progeny contribute more than 50% of natural background radiation dose to human being. The time integrated passive measurements of radon, thoron and their progeny concentrations were carried out in the dwellings of Pauri Garhwal, Uttarakhand, India. The measurements of radon and thoron concentrations were performed by LR-115 detector based single entry Pin-Hole dosimeter while for the measurement of progeny concentrations, LR-115 deposition based DTPS/DRPS technique was used. The experimental techniques and results obtained are discussed in detail. (author)

  1. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    Science.gov (United States)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-01

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO2) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO2) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO2 and HHb, total haemoglobin concentration and SO2. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l-1 (±58 µM) and ±4

  2. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    Energy Technology Data Exchange (ETDEWEB)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul [Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, London WC1E 6BT (United Kingdom)

    2007-01-07

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO{sub 2}) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO{sub 2}) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO{sub 2} and HHb, total haemoglobin concentration and SO{sub 2}. The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of {+-}3

  3. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration

    International Nuclear Information System (INIS)

    Laufer, Jan; Delpy, Dave; Elwell, Clare; Beard, Paul

    2007-01-01

    A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO 2 ) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO 2 ) and total haemoglobin concentration. It can also be used to quantify the local accumulation of targeted contrast agents used in photoacoustic molecular imaging. The technique employs a model-based inversion scheme to recover the chromophore concentrations from photoacoustic measurements. This comprises a numerical forward model of the detected time-dependent photoacoustic signal that incorporates a multiwavelength diffusion-based finite element light propagation model to describe the light transport and a time-domain acoustic model to describe the generation, propagation and detection of the photoacoustic wave. The forward model is then inverted by iteratively fitting it to measurements of photoacoustic signals acquired at different wavelengths to recover the chromophore concentrations. To validate this approach, photoacoustic signals were generated in a tissue phantom using nanosecond laser pulses between 740 nm and 1040 nm. The tissue phantom comprised a suspension of intralipid, blood and a near-infrared dye in which three tubes were immersed. Blood at physiological haemoglobin concentrations and oxygen saturation levels ranging from 2% to 100% was circulated through the tubes. The signal amplitude from different temporal sections of the detected photoacoustic waveforms was plotted as a function of wavelength and the forward model fitted to these data to recover the concentrations of HbO 2 and HHb, total haemoglobin concentration and SO 2 . The performance was found to compare favourably to that of a laboratory CO-oximeter with measurement resolutions of ±3.8 g l -1 (±58

  4. Bisphenol A and alkylphenols concentrations in selected mariculture fish species from Pulau Kukup, Johor, Malaysia.

    Science.gov (United States)

    Ismail, Nur Afifah Hanun; Wee, Sze Yee; Aris, Ahmad Zaharin

    2018-02-01

    Endocrine disrupting compound (EDC) contamination in food is a global concern. Concerning potential environmental and human health exposed to EDCs via food intake, an experiment was conducted on the selected EDCs concentration in the mariculture fish, Trachinotus blochii (golden pomfret), Lutjanus campechanus (snapper), and Lates calcarifer (sea bass) at Pulau Kukup, Johor. Mariculture activity at Pulau Kukup involves active export of fishes to Singapore and Indonesia. The recovery of BPA (bisphenol A), 4OP (4-octylphenol), and 4NP (4-nonylphenol) were 61.54%-93.00%, 16.79%-17.13%, and 61.24%-71.49%, respectively. Relatively high concentration of BPA was recorded in T. blochii (0.322ng/g), followed by L. calcarifer (0.124ng/g) and L. campechanus (0.023ng/g). Furthermore, 4OP and 4NP were detected only in T. blochii at concentrations of 0.084ng/g and 0.078ng/g, respectively. The results of the present study provide insights on monitoring and managing mariculture activity in relation to environmental protection and food safety. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Multi-species time-history measurements during high-temperature acetone and 2-butanone pyrolysis

    KAUST Repository

    Lam, Kingyiu

    2013-01-01

    High-temperature acetone and 2-butanone pyrolysis studies were conducted behind reflected shock waves using five species time-history measurements (ketone, CO, CH3, CH4 and C2H4). Experimental conditions covered temperatures of 1100-1600 Kat 1.6 atm, for mixtures of 0.25-1.5% ketone in argon. During acetone pyrolysis, the CO concentration time-history was found to be strongly sensitive to the acetone dissociation rate constant κ1 (CH3COCH3 → CH3 + CH3CO), and this could be directly determined from the CO time-histories, yielding κ1(1.6 atm) = 2.46 × 1014 exp(-69.3 [kcal/mol]/RT) s-1 with an uncertainty of ±25%. This rate constant is in good agreement with previous shock tube studies from Sato and Hidaka (2000) [3] and Saxena et al. (2009) [4] (within 30%) at temperatures above 1450 K, but is at least three times faster than the evaluation from Sato and Hidaka at temperatures below 1250 K. Using this revised κ1 value with the recent mechanism of Pichon et al. (2009) [5], the simulated profiles during acetone pyrolysis show excellent agreement with all five species time-history measurements. Similarly, the overall 2-butanone decomposition rate constant κtot was inferred from measured 2-butanone time-histories, yielding κ tot(1.5 atm) = 6.08 × 1013 exp(-63.1 [kcal/mol]/RT) s -1 with an uncertainty of ±35%. This rate constant is approximately 30% faster than that proposed by Serinyel et al. (2010) [11] at 1119 K, and approximately 100% faster at 1412 K. Using the measured 2-butanone and CO time-histories and an O-atom balance analysis, a missing removal pathway for methyl ketene was identified. The rate constant for the decomposition of methyl ketene was assumed to be the same as the value for the ketene decomposition reaction. Using the revised κtot value and adding the methyl ketene decomposition reaction to the Serinyel et al. mechanism, the simulated profiles during 2-butanone pyrolysis show good agreement with the measurements for all five species.

  6. The deconvolution of sputter-etching surface concentration measurements to determine impurity depth profiles

    International Nuclear Information System (INIS)

    Carter, G.; Katardjiev, I.V.; Nobes, M.J.

    1989-01-01

    The quasi-linear partial differential continuity equations that describe the evolution of the depth profiles and surface concentrations of marker atoms in kinematically equivalent systems undergoing sputtering, ion collection and atomic mixing are solved using the method of characteristics. It is shown how atomic mixing probabilities can be deduced from measurements of ion collection depth profiles with increasing ion fluence, and how this information can be used to predict surface concentration evolution. Even with this information, however, it is shown that it is not possible to deconvolute directly the surface concentration measurements to provide initial depth profiles, except when only ion collection and sputtering from the surface layer alone occur. It is demonstrated further that optimal recovery of initial concentration depth profiles could be ensured if the concentration-measuring analytical probe preferentially sampled depths near and at the maximum depth of bombardment-induced perturbations. (author)

  7. Methods to homogenize electrochemical concentration cell (ECC ozonesonde measurements across changes in sensing solution concentration or ozonesonde manufacturer

    Directory of Open Access Journals (Sweden)

    T. Deshler

    2017-06-01

    Full Text Available Ozone plays a significant role in the chemical and radiative state of the atmosphere. For this reason there are many instruments used to measure ozone from the ground, from space, and from balloons. Balloon-borne electrochemical cell ozonesondes provide some of the best measurements of the ozone profile up to the mid-stratosphere, providing high vertical resolution, high precision, and a wide geographic distribution. From the mid-1990s to the late 2000s the consistency of long-term records from balloon-borne ozonesondes has been compromised by differences in manufacturers, Science Pump (SP and ENSCI (EN, and differences in recommended sensor solution concentrations, 1.0 % potassium iodide (KI and the one-half dilution: 0.5 %. To investigate these differences, a number of organizations have independently undertaken comparisons of the various ozonesonde types and solution concentrations, resulting in 197 ozonesonde comparison profiles. The goal of this study is to derive transfer functions to allow measurements outside of standard recommendations, for sensor composition and ozonesonde type, to be converted to a standard measurement and thus homogenize the data to the expected accuracy of 5 % (10 % in the stratosphere (troposphere. Subsets of these data have been analyzed previously and intermediate transfer functions derived. Here all the comparison data are analyzed to compare (1 differences in sensor solution composition for a single ozonesonde type, (2 differences in ozonesonde type for a single sensor solution composition, and (3 the World Meteorological Organization's (WMO and manufacturers' recommendations of 1.0 % KI solution for Science Pump and 0.5 % KI for ENSCI. From the recommendations it is clear that ENSCI ozonesondes and 1.0 % KI solution result in higher amounts of ozone sensed. The results indicate that differences in solution composition and in ozonesonde type display little pressure dependence at pressures

  8. Bioaccumulation studies in a benthic marine species in different radioactivity concentrations

    International Nuclear Information System (INIS)

    Stamouli, M.; Papadopoulou, C.

    1992-07-01

    The accumulation of trivalent and hexavalent 51Cr by the mollusc Venus verrucosa in three different radioactivity concentrations was studied. The bioavailability of the trivalent 51Cr was found to be much higher than that of the hexavalent 51Cr. Also the uptake patterns of 51Cr(III) and 51Cr(VI) were different. This distribution of the accumulated trivalent and hexavalent 51Cr in the body of Venus verrucosa was investigated and appeared to be influenced by the valence state of 51Cr. The elimination of the accumulated radioactivity was also investigated and the effective and biological half lives for the two year valence states of 51Cr were determined

  9. Airborne plutonium-239 and americium-241 concentrations measured from the 125-meter Hanford Meteorological Tower

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1978-01-01

    Airborne plutonium-239 and americium-241 concentrations and fluxes were measured at six heights from 1.9 to 122 m on the Hanford meteorological tower. The data show that plutonium-239 was transported on nonrespirable and small particles at all heights. Airborne americium-241 concentrations on small particles were maximum at the 91 m height

  10. Predicting and measurement of pH of seawater reverse osmosis concentrates

    KAUST Repository

    Waly, Tarek; Kennedy, Maria Dolores; Witkamp, Geert-Jan; Amy, Gary L.; Schippers, Jan Cornelis

    2011-01-01

    The pH of seawater reverse osmosis plants (SWRO) is the most influential parameter in determining the degree of supersaturation of CaCO3 in the concentrate stream. For this, the results of pH measurements of the concentrate of a seawater reverse

  11. Variation in acrylamide concentration in French fries : effects of control measures in food service establishments

    NARCIS (Netherlands)

    Sanny, M.A.I.

    2012-01-01

    The aim of this thesis was first to identify the major technological and managerial factors and to investigate their contribution to variation in acrylamide concentrations. The second aim was to investigate the effect of technological and managerial control measures on the concentration and

  12. 40 CFR 761.298 - Decisions based on PCB concentration measurements resulting from sampling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Decisions based on PCB concentration... Cleanup and On-Site Disposal of Bulk PCB Remediation Waste and Porous Surfaces in Accordance With § 761.61(a)(6) § 761.298 Decisions based on PCB concentration measurements resulting from sampling. (a) For...

  13. Prompt gamma-ray spectrometry for measurement of B-10 concentration in brain tissue and blood

    International Nuclear Information System (INIS)

    Nakagawa, Yoshinobu; Kitamura, Katsuji; Kobayashi, Toru; Matsumoto, Keizo; Hatanaka, Hiroshi.

    1993-01-01

    Boron-10 (B-10) concentration in the brain tissue and blood was measured continuously for 24 hours after injection of the B-10 compound in live rabbits using prompt gamma-ray spectrometry. Following injection of B-10 compound (Na 2 B 12 H 11 SH, 50mg/kg) dissolved in physiological saline, B-10 concentration was continuously measured in the brain tissue. Intermittently the concentration of B-10 in blood and cerebro-spinal fluid (CSF) was also measured. In 10 minutes after the injection of B-10 compound, the level of B-10 concentration reached the peak of 400-500 ppm in blood and 20-30 ppm in the normal brain tissue. In 60 minutes the level of B-10 concentration rapidly decreased and then a gradual decline was observed. The value was 15-30 ppm at 3 hours after injection, 5-10 ppm at 6 hours and 2-5 ppm at 24 hours in the blood. The concentration in the brain tissue was 3-8 ppm at 3 hours, 2-5 ppm at 6 hours and below 1.5 ppm at 24 hours. B-10 concentration in cerebro-spinal fluid was below 1 ppm. B-10 concentration was also measured in the brain tumor and blood in the human cases at boron neutron capture therapy (BNCT). These data studied by prompt gamma-ray spectrometry are very important and useful to decide the irradiation time. (author)

  14. Processing-independent proANP measurement for low concentrations in plasma

    DEFF Research Database (Denmark)

    Mark, Peter D; Hunter, Ingrid; Terzic, Dijana

    2018-01-01

    BACKGROUND: Decreased concentrations of pro-atrial-derived natriuretic peptides (proABP) in plasma have been associated with obesity and suggested as a predictor of type 2 diabetes. However, assays for measuring proANP are generally aimed to quantitate higher concentrations of proANP associated...

  15. Measurements of the oxidation state and concentration of plutonium in interstitial waters of the Irish Sea

    International Nuclear Information System (INIS)

    Nelson, D.M.; Lovett, M.B.

    1980-01-01

    The question of plutonium movement in interstitial waters resulting from diffusion along concentration gradients or from advective flow is addressed. The results of measurements of both the concentration and the oxidation state of plutonium in interstitial water collected from sediments near the Windscale discharge, in the solid phases of these sediments and in seawater and suspended solids collected at the coring locations are discussed

  16. Exposition by inhalation to the formaldehyde in the air. Source, measures and concentrations

    International Nuclear Information System (INIS)

    Del Gratta, F.; Durif, M.; Fagault, Y.; Zdanevitch, I.

    2004-12-01

    This document presents the main techniques today available to characterize the formaldehyde concentrations in the air for different contexts: urban and rural areas or around industrial installations but also indoor and occupational area. It provides information to guide laboratories and research departments. A synthesis gives also the main emissions sources of these compounds as reference concentrations measured in different environments. (A.L.B.)

  17. About Error in Measuring Oxygen Concentration by Solid-Electrolyte Sensors

    Directory of Open Access Journals (Sweden)

    V. I. Nazarov

    2008-01-01

    Full Text Available The paper evaluates additional errors while measuring oxygen concentration in a gas mixture by a solid-electrolyte cell. Experimental dependences of additional errors caused by changes in temperature in a sensor zone, discharge of gas mixture supplied to a sensor zone, partial pressure in the gas mixture and fluctuations in oxygen concentrations in the air.

  18. Evaluation and Comparison of Chemiluminescence and UV Photometric Methods for Measuring Ozone Concentrations in Ambient Air

    Science.gov (United States)

    The current Federal Reference Method (FRM) for measuring concentrations of ozone in ambient air is based on the dry, gas-phase, chemiluminescence reaction between ethylene (C2H4) and any ozone (O3) that may be p...

  19. Optimisation of elevated radon concentration measurement by using electro-chemical etching of nuclear track detectors

    International Nuclear Information System (INIS)

    Celikovic, I.; Ujic, P.; Fujimoto, K.; Tommasino, L.; Demajo, A.; Zunic, Z.; Celikovic, I.)

    2007-01-01

    In the paper, two methods for adjusting of passive radon-thoron discriminative dosimeters (UFO detector) for enhanced radon concentration measurement are presented. Achieved upper limit of detection is 5.94 MBq m-3 d [sr

  20. Laser-Based Optical System for Reactive Radical Concentration Measurements in Plasmas and Flames

    National Research Council Canada - National Science Library

    Fridman, Alexander

    2006-01-01

    Defense University Research Instrumentation Program (DURIP) funding was used to assemble a multi-purpose optical diagnostic system for in-situ radical concentration measurements in plasma and combustion systems...

  1. Development of automatic high-concentration boron measurement technique; Konodo hoso jido sokutei gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, T.; Honda, S.; Ito, A. [Kyushu Electric Power Co. Inc., Fukuoka (Japan)

    1997-03-01

    The technology that can automatically measure the boron concentration in boric acid water was developed. A high-concentration boric acid solution must be held at a high temperature to prevent the deposition. Skill and precision ({plus_minus}0.2 to 0.3% for 10 to 2500 ppm as boron concentration, and {plus_minus}2 to 3% for 2500 to 25,000 ppm) are required to analyze the boric acid solution manually. In theory, the boron concentration in a wide range can be measured, and boron has a constant-temperature function. A density hydrometer method that facilitates the treatment and calibration in high precision and at low cost was chosen. The vibration period generated when vibration is given to the solution specimen put in a U-tube is higher as the density is lower. On the basis of this theory, the density of a specimen can be obtained according to the relation with the same data of the known-concentration boric acid water. The high-concentration boric acid water that cannot be measured by the existing boron densitometer can be measured directly. It can also be measured in a low-concentration area. The technique can be used in a laboratory as the simplified method that is replaced by the current manual analysis. The reduction effect of analytical chemical`s waste liquid can also be expected. In the electric power industry, automated equipment is required for high efficiency and labor saving. 13 figs., 3 tabs.

  2. Egg laying sequence influences egg mercury concentrations and egg size in three bird species: Implications for contaminant monitoring programs

    Science.gov (United States)

    Ackerman, Joshua T.; Eagles-Smith, Collin A.; Herzog, Mark P.; Yee, Julie L.; Hartman, C. Alex

    2016-01-01

    Bird eggs are commonly used in contaminant monitoring programs and toxicological risk assessments, but intra-clutch variation and sampling methodology could influence interpretability. We examined the influence of egg laying sequence on egg mercury concentrations and burdens in American avocets, black-necked stilts, and Forster's terns. The average decline in mercury concentrations between the first and last egg laid was 33% for stilts, 22% for terns, and 11% for avocets, and most of this decline occurred between the first and second eggs laid (24% for stilts, 18% for terns, and 9% for avocets). Trends in egg size with egg laying order were inconsistent among species and overall differences in egg volume, mass, length, and width were mercury concentrations generally declined by 16% between the first and second eggs laid. Despite the strong effect of egg laying sequence, most of the variance in egg mercury concentrations still occurred among clutches (75%-91%) rather than within clutches (9%-25%). Using simulations, we determined that to accurately estimate a population's mean egg mercury concentration using only a single random egg from a subset of nests, it would require sampling >60 nests to represent a large population (10% accuracy) or ≥14 nests to represent a small colony that contained <100 nests (20% accuracy).

  3. Estimation of release of tritium from measurements of air concentrations in reactor building of PHWR

    International Nuclear Information System (INIS)

    Purohit, R.G.; Sarkar, P.K.

    2010-01-01

    In this paper an attempt has been made to estimate the releases from measured air concentrations of tritium at various locations in Reactor Building (RB). Design data of Kaiga Generating Station and sample measurements of tritium concentrations at various locations in RB and discharges for a period of fortnight were used. A comparison has also been made with actual measurements. It has been observed that there is good matching in estimated and actual measurements of tritium release on some days while on some days there is high difference

  4. Fine particle number and mass concentration measurements in urban Indian households.

    Science.gov (United States)

    Mönkkönen, P; Pai, P; Maynard, A; Lehtinen, K E J; Hämeri, K; Rechkemmer, P; Ramachandran, G; Prasad, B; Kulmala, M

    2005-07-15

    Fine particle number concentration (D(p)>10 nm, cm(-3)), mass concentrations (approximation of PM(2.5), microg m(-3)) and indoor/outdoor number concentration ratio (I/O) measurements have been conducted for the first time in 11 urban households in India, 2002. The results indicate remarkable high indoor number and mass concentrations and I/O number concentration ratios caused by cooking. Besides cooking stoves that used liquefied petroleum gas (LPG) or kerosene as the main fuel, high indoor concentrations can be explained by poor ventilation systems. Particle number concentrations of more than 300,000 cm(-3) and mass concentrations of more than 1000 microg m(-3) were detected in some cases. When the number and mass concentrations during cooking times were statistically compared, a correlation coefficient r>0.50 was observed in 63% of the households. Some households used other fuels like wood and dung cakes along with the main fuel, but also other living activities influenced the concentrations. In some areas, outdoor combustion processes had a negative impact on indoor air quality. The maximum concentrations observed in most cases were due to indoor combustion sources. Reduction of exposure risk and health effects caused by poor indoor air in urban Indian households is possible by improving indoor ventilation and reducing penetration of outdoor particles.

  5. Growth response of four freshwater algal species to dissolved organic nitrogen of different concentration and complexity

    DEFF Research Database (Denmark)

    Fiedler, Dorothea; Graeber, Daniel; Badrian, Maria

    2015-01-01

    1. Dissolved organic nitrogen (DON) compounds dominate the nitrogen pool of many lakes, but their importance as nitrogen sources for freshwater phytoplankton is not fully understood. Previous growth experiments demonstrated the availability of urea and amino acids but often at unnaturally high...... (DCAA), natural organic matter (NOM)) or with nitrate as the sole nitrogen source. Monocultures of Chlamydomonas spp., Cyclotella meneghiniana, Microcystis aeruginosa and Anabaena flos-aquae were incubated with dissolved nitrogen compounds at concentrations ranging from 0.01 to 0.5 mg N L−1, which...... and their compound preferences. Therefore, DON composition can influence biomass and structure of phytoplankton communities. 6. These experiments demonstrate the importance of the main DON compounds for phytoplankton growth when no inorganic nitrogen is available. DON should in future be included in nitrogen budget...

  6. [Identification of spill oil species based on low concentration synchronous fluorescence spectra and RBF neural network].

    Science.gov (United States)

    Liu, Qian-qian; Wang, Chun-yan; Shi, Xiao-feng; Li, Wen-dong; Luan, Xiao-ning; Hou, Shi-lin; Zhang, Jin-liang; Zheng, Rong-er

    2012-04-01

    In this paper, a new method was developed to differentiate the spill oil samples. The synchronous fluorescence spectra in the lower nonlinear concentration range of 10(-2) - 10(-1) g x L(-1) were collected to get training data base. Radial basis function artificial neural network (RBF-ANN) was used to identify the samples sets, along with principal component analysis (PCA) as the feature extraction method. The recognition rate of the closely-related oil source samples is 92%. All the results demonstrated that the proposed method could identify the crude oil samples effectively by just one synchronous spectrum of the spill oil sample. The method was supposed to be very suitable to the real-time spill oil identification, and can also be easily applied to the oil logging and the analysis of other multi-PAHs or multi-fluorescent mixtures.

  7. Whispering Gallery Mode Based Optical Fiber Sensor for Measuring Concentration of Salt Solution

    Directory of Open Access Journals (Sweden)

    Chia-Chin Chiang

    2013-01-01

    Full Text Available An optical fiber solution-concentration sensor based on whispering gallery mode (WGM is proposed in this paper. The WGM solution-concentration sensors were used to measure salt solutions, in which the concentrations ranged from 1% to 25% and the wavelength drifted from the left to the right. The experimental results showed an average sensitivity of approximately 0.372 nm/% and an R2 linearity of 0.8835. The proposed WGM sensors are of low cost, feasible for mass production, and durable for solution-concentration sensing.

  8. Determination of potassium concentration in salt water for residual beta radioactivity measurements

    International Nuclear Information System (INIS)

    Suarez-Navarro, J.A.; Pujol, Ll.

    2004-01-01

    High interferences may arise in the determination of potassium concentration in salt water. Several analytical methods were studied to determine which method provided the most accurate measurements of potassium concentration. This study is relevant for radiation protection because the exact amount of potassium in water samples must be known for determinations of residual beta activity concentration. The fitting algorithm of the calibration curve and estimation of uncertainty in potassium determinations were also studied. The reproducibility of the proposed analytical method was tested by internal and external validation. Furthermore, the residual beta activity concentration of several Spanish seawater and brackish river water samples was determined using the proposed method

  9. Differential Mueller matrix polarimetry technique for non-invasive measurement of glucose concentration on human fingertip.

    Science.gov (United States)

    Phan, Quoc-Hung; Lo, Yu-Lung

    2017-06-26

    A differential Mueller matrix polarimetry technique is proposed for obtaining non-invasive (NI) measurements of the glucose concentration on the human fingertip. The feasibility of the proposed method is demonstrated by detecting the optical rotation angle and depolarization index of tissue phantom samples containing de-ionized water (DI), glucose solutions with concentrations ranging from 0~500 mg/dL and 2% lipofundin. The results show that the extracted optical rotation angle increases linearly with an increasing glucose concentration, while the depolarization index decreases. The practical applicability of the proposed method is demonstrated by measuring the optical rotation angle and depolarization index properties of the human fingertips of healthy volunteers.

  10. Chromatographic method of measurement of helium concentration in underground waters for dating in hydrological questions

    International Nuclear Information System (INIS)

    Najman, J.

    2008-04-01

    Research methods which use natural environmental indicators are widely applied in hydrology. Different concentrations of indicators and their isotopic components in ground waters allow to determine the genesis of waters and are valuable source of information about the water flow dynamics. One of the significant indicator is helium. The concentration of 4 He (helium) in ground water is a fine indicator in water dating in a range from a hundreds to millions of years (Aeschbach-Hertig i in., 1999; Andrews i in., 1989; Castro i in., 2000; Zuber i in., 2007). 4 He is also used for dating young waters of age about 10 years (Solomon i in., 1996). Thesis consist the description of elaborated in IFJ PAN in Krakow chromatographic measurement method of helium concentration in ground waters in aim of dating. Chapter 1 contain short introduction about ground water dating and chapter 2 description of helium property and chosen applications of helium for example in technology and earthquake predictions. Helium sources in ground waters are described in chapter 3. Helium concentration in water after infiltration (originated from atmosphere) to the ground water system depends mainly on the helium concentration coming from the equilibration with the atmosphere increased by additional concentration from '' excess air ''. With the increasing resistance time of ground water during the flow, radiogenic, non-atmospheric component of helium dissolves also in water. In chapter 4 two measurement methods of helium concentration in ground waters were introduced: mass spectrometric and gas chromatographic method. Detailed description of elaborated chromatographic measurement method of helium concentration in ground water contain chapter 5. To verify developed method the concentration of helium in ground waters from the regions of Krakow and Busko Zdroj were measured. For this waters the concentrations of helium are known from the earlier mass spectrometric measurements. The results of

  11. ESR measurement of the concentration of vibrationally excited hydrogen and deuterium molecules

    International Nuclear Information System (INIS)

    Gershenzon, Yu.M.; Ivanov, A.V.; Il'in, S.D.; Kucheryavyi, S.I.; Rozenshtein, V.B.

    1988-01-01

    A method is described for measuring the concentration of vibrationally excited H 2 and D 2 molecules using an ESR microwave spectrometer. The essence of the method is the titration of H 2 (v = 1) and D 2 (v = 1) with D and H atoms and measurement of the concentrations of the titration products H and D, respectively. Stoichiometric titration coefficients were determined in the form of proportionality coefficients between the titration signals Δ[H], Δ[D] and the concentrations of H 2 (v = 1), D 2 (v = 1)

  12. Measurement of Radon concentration in groundwater by technique of nuclear track detector

    International Nuclear Information System (INIS)

    Trinh Van Giap; Nguyen Manh Hung; Dang Duc Nhan

    2000-01-01

    A method for measuring radon concentration in groundwater using nuclear track detector LR-115 stripping is reported. The radon-monitoring device in groundwater is a small box with two pieces of nuclear track detector and all these materials is placed in a plastic bag made by polyethylene. It is very suitable to measure radon concentration in groundwater well in long term. Alpha tracks produced by radon and it daughter on nuclear track detector is counted automatically by spark counting method. The paper also presents some results of radon concentration in some groundwater well and mineral water sources. (author)

  13. Results of long-term measurement of 222Rn concentrations in outdoor atmosphere

    International Nuclear Information System (INIS)

    Holy, K.; Boehm, R.; Polaskova, A.; Hola, O.

    1998-01-01

    Results are reported of the authors' long-term measurement of 222 Rn concentrations in the outdoor atmosphere. The measurements started in 1987 and were performed at a height of 1.5 m over a grass-covered ground surface, using till 1991 a Lucas type scintillation chamber and later a large volume scintillation chamber. Graphs are presented and discussed of the course of average monthly radon concentration in 1987-1996 and of annual courses of radon concentration for different time intervals of the day over 1991 to 1995. (A.K.)

  14. Measurement of 222Rn concentration in drinking water in the environs of Thirthahalli taluk, Karnataka, India

    Directory of Open Access Journals (Sweden)

    G.M. Shilpa

    2017-07-01

    Full Text Available The dissolved radon concentration in water samples collected from various aquifers in and around Thirthahalli taluk was measured by employing active technique through Scintillation Radon Monitoring system. The measured radon concentration lies in the range of 0.37 ± 0.05 Bq/l to 87.02 ± 2.11 Bq/l. The resulting annual effective radiation dose to the public, who consume this water, lies in the range of 1.01μSvy−1 to 237.56 μSvy−1. However, no significant change in the radon concentration with respect to seasonal variation was observed in majority of the sample. Few samples show higher radon concentration during summer season and lower concentration in rainy season. All these results are presented in this paper.

  15. Seasonal and species-specific response of VOC emissions by Mediterranean woody plant to elevated ozone concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Llusia, J.; Penuelas, J. [Universitat Autonoma de Barcelona (Spain). Unitat Ecofisiologia CSIC-CEAB-CREAF; Gimeno, R.S. [CIEMAT, Madrid (Spain). Ecotoxicologia de la Contaminacion Atmosferica

    2002-08-01

    Although certain factors controlling plant emission rates of volatile organic compounds (VOCs) are reasonably well understood, the influence of elevated ozone concentrations as abiotic stress is mostly unknown. Therefore, we studied the effects of ozone concentrations on seasonal biogenic volatile organic compound (BVOC) emissions by different Mediterranean plant species in open top chambers (OTC). Three ozone treatments were established: filtered air (F), non-filtered air (NF), and fumigated air (NF+) adding 40 nl l{sup -1} of ozone over NF. We studied the response of VOC emission in saplings of four Mediterranean woody plant species and subspecies: Ceratonia siliqua L., Olea europaea L., Quercus ilex spp. ilex L., and Quercus ilex spp. rotundifolia L. as representative of natural Mediterranean vegetation. No visible symptoms were detected on the leaves. No significant effect was found on net photosynthetic rates or stomatal conductance except for an increase in net photosynthetic rates in Quercus ilex ilex in spring and summer and an overall slight increase in Quercus ilex rotundifolia. Emissions of the total VOCs from Ceratonia siliqua in summer, and from Olea europaea and Quercus ilex rotundifolia in spring increased in ozone fumigated OTC in comparison with F or NF OTC. Decreased emissions were found in Quercus ilex rotundifolia in summer. There were no significant differences between ozone fumigation treatments for the other plant species and seasons. When considering particular VOCs, the results were also variable among species and time of the year. While {alpha}-pinene emissions decreased with ozone fumigation in Olea europaea, {alpha}-pinene and limonene emissions increased in Quercus ilex ilex. The responses of these particular VOCs did not always match the responses of total VOCs. In spite of this strong variability, when considering overall annual data for all species and seasons, there were increased net photosynthetic rates (37%) and limonene (95

  16. Seasonal and species-specific response of VOC emissions by Mediterranean woody plant to elevated ozone concentrations

    Science.gov (United States)

    Llusià, J.; Peñuelas, J.; Gimeno, B. S.

    Although certain factors controlling plant emission rates of volatile organic compounds (VOCs) are reasonably well understood, the influence of elevated ozone concentrations as abiotic stress is mostly unknown. Therefore, we studied the effects of ozone concentrations on seasonal biogenic volatile organic compound (BVOC) emissions by different Mediterranean plant species in open top chambers (OTC). Three ozone treatments were established: filtered air (F), non-filtered air (NF), and fumigated air (NF+) adding 40 nl l -1 of ozone over NF. We studied the response of VOC emission in saplings of four Mediterranean woody plant species and subspecies: Ceratonia siliqua L., Olea europaea L., Quercus ilex spp. ilex L., and Quercus ilex spp. rotundifolia L. as representative of natural Mediterranean vegetation. No visible symptoms were detected on the leaves. No significant effect was found on net photosynthetic rates or stomatal conductance except for an increase in net photosynthetic rates in Quercus ilex ilex in spring and summer and an overall slight increase in Quercus ilex rotundifolia. Emissions of the total VOCs from Ceratonia siliqua in summer, and from Olea europaea and Quercus ilex rotundifolia in spring increased in ozone fumigated OTC in comparison with F or NF OTC. Decreased emissions were found in Quercus ilex rotundifolia in summer. There were no significant differences between ozone fumigation treatments for the other plant species and seasons. When considering particular VOCs, the results were also variable among species and time of the year. While α-pinene emissions decreased with ozone fumigation in Olea europaea, α-pinene and limonene emissions increased in Quercus ilex ilex. The responses of these particular VOCs did not always match the responses of total VOCs. In spite of this strong variability, when considering overall annual data for all species and seasons, there were increased net photosynthetic rates (37%) and limonene (95%) and total VOC (45

  17. Study of carrier concentration in single InP nanowires by luminescence and Hall measurements

    International Nuclear Information System (INIS)

    Lindgren, David; Hultin, Olof; Heurlin, Magnus; Storm, Kristian; Borgström, Magnus T; Samuelson, Lars; Gustafsson, Anders

    2015-01-01

    The free electron carrier concentrations in single InP core–shell nanowires are determined by micro-photoluminescence, cathodoluminescence (CL) and Hall effect measurements. The results from luminescence measurements were obtained by solving the Fermi–Dirac integral, as well as by analyzing the peak full width at half maximum (FWHM). Furthermore, the platform used for Hall effect measurements, combined with spot mode CL spectroscopy, is used to determine the carrier concentrations at specific positions along single nanowires. The results obtained via luminescence measurements provide an accurate and rapid feedback technique for the epitaxial development of doping incorporation in nanowires. The technique has been employed on several series of samples in which growth parameters, such as V/III-ratio, temperature and dopant flows, were investigated in an optimization procedure. The correlation between the Hall effect and luminescence measurements for extracting the carrier concentration of different samples were in excellent agreement. (paper)

  18. Implementation of gas concentration measurement systems using mass spectrometry in containment thermal-hydraulics test facilities: different approaches for calibration and measurement with steam/air/helium mixtures

    International Nuclear Information System (INIS)

    Auban, O.; Malet, J.; Brun, P.; Brinster, J.; Quillico, J. J.; Studer, E.

    2003-01-01

    Thermal-hydraulic test facilities are used to investigate various containment phenomena such as, for example, mixing and stratification of gases or steam condensation in the presence of noncondensable. Experiments are also required for validation of codes possessing capabilities for modelling such three-dimensional effects. The need for advanced instrumentation allowing to measure gas concentration in such conditions (typically: 100-180 .deg. C; 1-10 bar) and to get sufficiently refined information about spatial distribution of the different gas species has become apparent. This paper deals with the implementation of gas analysis systems using some commercial Quadrupole Mass Spectrometers (QMS) that have been recently added to the basic instrumentation in three thermal-hydraulics test facilities namely MISTRA (CEA, France), TOSQAN (IRSN, France) and PANDA (PSI, Switzerland). In recent years, QMS have increasingly been selected for various applications because of attractive metrological characteristics (sensibility, span of concentration range, response time, stability, etc.), relatively compact size and low cost. Although commercial QMS are sold as 'turnkey' systems, these instruments are delicate to bring into operation. As QMS are not absolute instruments, reliable calibration procedures are required for quantitative measurements. A mass spectrometer can be regarded as an ionisation gauge with subsequent separation system for the different ion species. The calculation of gas concentrations considers the partial pressure of a particular gas species to be proportional to the ion current it generates. Anyway, one must know the QMS sensitivity to the gases of interest and the only practical method is to use calibration gases. Calibration must be carried out using mixtures whose compositions are close to any possible sample compositions and the procedure selected should duplicate as closely as possible the measurement conditions established during the real experiment

  19. Sequential Measurement of Intermodal Variability in Public Transportation PM2.5 and CO Exposure Concentrations.

    Science.gov (United States)

    Che, W W; Frey, H Christopher; Lau, Alexis K H

    2016-08-16

    A sequential measurement method is demonstrated for quantifying the variability in exposure concentration during public transportation. This method was applied in Hong Kong by measuring PM2.5 and CO concentrations along a route connecting 13 transportation-related microenvironments within 3-4 h. The study design takes into account ventilation, proximity to local sources, area-wide air quality, and meteorological conditions. Portable instruments were compacted into a backpack to facilitate measurement under crowded transportation conditions and to quantify personal exposure by sampling at nose level. The route included stops next to three roadside monitors to enable comparison of fixed site and exposure concentrations. PM2.5 exposure concentrations were correlated with the roadside monitors, despite differences in averaging time, detection method, and sampling location. Although highly correlated in temporal trend, PM2.5 concentrations varied significantly among microenvironments, with mean concentration ratios versus roadside monitor ranging from 0.5 for MTR train to 1.3 for bus terminal. Measured inter-run variability provides insight regarding the sample size needed to discriminate between microenvironments with increased statistical significance. The study results illustrate the utility of sequential measurement of microenvironments and policy-relevant insights for exposure mitigation and management.

  20. 75 FR 30483 - Atlantic Highly Migratory Species; Atlantic Shark Management Measures; Amendment 3

    Science.gov (United States)

    2010-06-01

    ... and 635 Atlantic Highly Migratory Species; Atlantic Shark Management Measures; Amendment 3; Final Rule... and 635 [Docket No. 080519678-0217-02] RIN 0648-AW65 Atlantic Highly Migratory Species; Atlantic Shark... available to rebuild blacknose sharks and end overfishing of blacknose and shortfin mako sharks, consistent...

  1. The measurement of thoron concentrations in Australia using the Japanese passive R-T dosimeter

    International Nuclear Information System (INIS)

    Toussaint, L.F.; Tokonami, S.; Doi, M.; Solomon, S.B.; Peggie, J.R.

    1998-01-01

    Previous studies have shown higher gamma radiation levels and higher soil thorium concentrations in the Darling Scarp area to the east of the city of Perth in Western Australia. It was considered desirable to measure the concentrations of the 220 Rn (thoron) in houses built near such areas and compare these measurements with similar measurements at other sites within Australia. A monitor developed for surveying 220 Rn and 222 Rn levels in Japan was considered most suitable for this purpose. The monitor used for the survey was a passive radon-thoron discriminative dosimeter, similar in type to that used to measure thoron concentrations in traditional Japanese houses. Houses for this study were selected from areas in the Darling Scarp. To provide data on what might be considered typical thoron concentrations associated with other soil types within Australia, a small number of houses in areas on the coastal plain of Western Australia and from the coastal areas of Victoria were also monitored. The mean thoron concentration in homes on the Darling Scarp of 14.0 Bq.m -3 was higher than that in the coastal plain in Western Australia (3.0 Bq.m -3 ) but comparable to the measurements in Victoria (11.3 Bq.m -3 ). For the radon measurements in homes, the mean Scarp concentration was typically 49.2 Bq.m -3 while the WA coastal plain and in Victoria mean concentrations were 11.6 Bq.m -3 and 15.4 Bq.m -3 respectively. For outdoors in the Darling Scarp, the thoron mean was 76.3 Bq.m -3 while the radon level was 18.2 Bq.m -3 . These measurements would suggest that the source of the thoron in homes on the Scarp is from the underlying soil rather than from the building materials. (author)

  2. Studies on measurement of chloride ion concentration in concrete structures with long-period grating sensors

    Science.gov (United States)

    Tang, Jaw-Luen; Chiang, Tsung-Yu; Chang, Hsiang-Ping; Wang, Jian-Neng

    2006-03-01

    We report the development and demonstration of a simple and low-cost long-period grating (LPG) sensor for chloride ion concentration measurement in concrete structures. The LPG sensor is extremely sensitive to the refractive index of the medium surrounding the cladding surface of the sensing grating, thus allowing it to be used as an ambient index sensor or chemical concentration indicator with high stability and reliability. We have measured chloride ion levels in a concrete sample immersed in salt water solution with different weight concentration ranging from 0 % to 20 %, and results showed that the LPG sensor exhibited a linear decrease in the transmission loss and resonance wavelength shift when the concentration increased. The measurement accuracy for concentration of salt in water solution is estimated to be 0.6 % and the limit of detection for chloride ion is about 0.04 %. To further enhance its sensitivity for chloride concentrations, we have coated gold nanoparticles on the grating surface of the LPG sensor. The sensing mechanism is based on the sensitivity of localized surface plasmon resonance of self-assembled Au colloids on the grating portion of the LPG. With this method, a factor of two increases in sensitivity of detecting chemical solution concentrations was obtained. The advantage of this type of the sensor is relatively simple of construction and ease of use. Moreover, the sensor has the potential capability for on-site, in vivo, and remote sensing, and has the potential use for disposable sensors.

  3. Measurements and predictors of on-road ultrafine particle concentrations and associated pollutants in Los Angeles

    Energy Technology Data Exchange (ETDEWEB)

    Fruin, S. [California Air Resources Board, Sacramento (United States); University of Southern California, Los Angeles (United States). Keck School of Medicine, Department of Preventive Medicine; Westerdahl, D.; Sax, T. [California Air Resources Board, Sacramento (United States); Sioutas, C. [University of Southern California, Los Angeles (United States). Civil and Environmental Engineering; Fine, P.M. [University of Southern California, Los Angeles (United States). Civil and Environmental Engineering; South Coast Air Quality Management District, Diamond Bar, CA (United States)

    2008-01-15

    Motor vehicles are the dominant source of oxides of nitrogen (NO{sub x}), particulate matter(PM), and certain air toxics (e.g., benzene, 1,3-butadiene) in urban areas. On roadways, motor vehicle-related pollutant concentrations are typically many times higher than ambient concentrations. Due to high air exchange rates typical of moving vehicles, this makes time spent in vehicles on roadways a major source of exposure. This paper presents on-road measurements for Los Angeles freeways and arterial roads taken from a zero-emission electric vehicle outfitted with real-time instruments. The objective was to characterize air pollutant concentrations on roadways and identify the factors associated with the highest concentrations. Our analysis demonstrated that on freeways, concentrations of ultrafine particles (UFPs), black carbon, nitric oxide, and PM-bound polycyclic aromatic hydrocarbons (PM-PAH) are generated primarily by diesel-powered vehicles, despite the relatively low fraction ({approx}6%) of diesel-powered vehicles on Los Angeles freeways. However, UFP concentrations on arterial roads appeared to be driven primarily by proximity to gasoline-powered vehicles undergoing hard accelerations. Concentrations were roughly one-third of those on freeways. By using a multiple regression model for the freeway measurements, we were able to explain 60-70% of the variability in concentrations of UFP, black carbon, nitric oxide, and PM-PAH using measures of diesel truck density and hour of day (as an indicator of wind speed). Freeway concentrations of these pollutants were also well correlated wth readily available annual average daily truck counts, potentially allowing improved population exposure estimates for epidemiology studies. Based on these roadway measurements and average driving time, it appears that 33-45% of total UFP exposure for Los Angeles residents occurs due to time spent traveling in vehicles. (author)

  4. Measurements and predictors of on-road ultrafine particle concentrations and associated pollutants in Los Angeles

    International Nuclear Information System (INIS)

    Fruin, S.; Sioutas, C.

    2008-01-01

    Motor vehicles are the dominant source of oxides of nitrogen (NO x ), particulate matter(PM), and certain air toxics (e.g., benzene, 1,3-butadiene) in urban areas. On roadways, motor vehicle-related pollutant concentrations are typically many times higher than ambient concentrations. Due to high air exchange rates typical of moving vehicles, this makes time spent in vehicles on roadways a major source of exposure. This paper presents on-road measurements for Los Angeles freeways and arterial roads taken from a zero-emission electric vehicle outfitted with real-time instruments. The objective was to characterize air pollutant concentrations on roadways and identify the factors associated with the highest concentrations. Our analysis demonstrated that on freeways, concentrations of ultrafine particles (UFPs), black carbon, nitric oxide, and PM-bound polycyclic aromatic hydrocarbons (PM-PAH) are generated primarily by diesel-powered vehicles, despite the relatively low fraction (∼6%) of diesel-powered vehicles on Los Angeles freeways. However, UFP concentrations on arterial roads appeared to be driven primarily by proximity to gasoline-powered vehicles undergoing hard accelerations. Concentrations were roughly one-third of those on freeways. By using a multiple regression model for the freeway measurements, we were able to explain 60-70% of the variability in concentrations of UFP, black carbon, nitric oxide, and PM-PAH using measures of diesel truck density and hour of day (as an indicator of wind speed). Freeway concentrations of these pollutants were also well correlated wth readily available annual average daily truck counts, potentially allowing improved population exposure estimates for epidemiology studies. Based on these roadway measurements and average driving time, it appears that 33-45% of total UFP exposure for Los Angeles residents occurs due to time spent traveling in vehicles. (author)

  5. Measurements and predictors of on-road ultrafine particle concentrations and associated pollutants in Los Angeles

    Science.gov (United States)

    Fruin, S.; Westerdahl, D.; Sax, T.; Sioutas, C.; Fine, P. M.

    Motor vehicles are the dominant source of oxides of nitrogen (NO x), particulate matter (PM), and certain air toxics (e.g., benzene, 1,3-butadiene) in urban areas. On roadways, motor vehicle-related pollutant concentrations are typically many times higher than ambient concentrations. Due to high air exchange rates typical of moving vehicles, this makes time spent in vehicles on roadways a major source of exposure. This paper presents on-road measurements for Los Angeles freeways and arterial roads taken from a zero-emission electric vehicle outfitted with real-time instruments. The objective was to characterize air pollutant concentrations on roadways and identify the factors associated with the highest concentrations. Our analysis demonstrated that on freeways, concentrations of ultrafine particles (UFPs), black carbon, nitric oxide, and PM-bound polycyclic aromatic hydrocarbons (PM-PAH) are generated primarily by diesel-powered vehicles, despite the relatively low fraction (˜6%) of diesel-powered vehicles on Los Angeles freeways. However, UFP concentrations on arterial roads appeared to be driven primarily by proximity to gasoline-powered vehicles undergoing hard accelerations. Concentrations were roughly one-third of those on freeways. By using a multiple regression model for the freeway measurements, we were able to explain 60-70% of the variability in concentrations of UFP, black carbon, nitric oxide, and PM-PAH using measures of diesel truck density and hour of day (as an indicator of wind speed). Freeway concentrations of these pollutants were also well correlated with readily available annual average daily truck counts, potentially allowing improved population exposure estimates for epidemiology studies. Based on these roadway measurements and average driving time, it appears that 33-45% of total UFP exposure for Los Angeles residents occurs due to time spent traveling in vehicles.

  6. K-edge x-ray fluorescence analysis for actinide and heavy elements solution concentration measurements

    International Nuclear Information System (INIS)

    Camp, D.C.

    1984-07-01

    Advantages of using Co-57 as an exciter for K XRFA include: a compact design that requires no x-ray tubes; the exciter-detector assembly locates remote from support electronics; on-line, at-line, or off-line configurations for monitor/measurements; systems that can be run by semi-skilled technicians, once programmed; and operated via remote terminals with results sent to control rooms; heavy element concentrations that are measurable thru industrial pipes; independent of minor changes in solution matrix or source half life with concentration results reported in near-real-time; a dynamic range of measurable concentrations that is greater than 10 4 ; measurement times that are reasonable even at 1 gram/liter; and for nuclear safeguards, it provides the <0.5% accuracy required by DOE for the accountability of U, Pu, or both, once the system is calibrated

  7. Accurate measurement of indoor radon concentration using a low-effective volume radon monitor

    International Nuclear Information System (INIS)

    Tanaka, Aya; Minami, Nodoka; Mukai, Takahiro; Yasuoka, Yumi; Iimoto, Takeshi; Omori, Yasutaka; Nagahama, Hiroyuki; Muto, Jun

    2017-01-01

    AlphaGUARD is a low-effective volume detector and one of the most popular portable radon monitors which is currently available. This study investigated whether AlphaGUARD can accurately measure the variable indoor radon levels. The consistency of the radon-concentration data obtained by AlphaGUARD is evaluated against simultaneous measurements by two other monitors (each ∼10 times more sensitive than AlphaGUARD). When accurately measuring radon concentration with AlphaGUARD, we found that the net counts of the AlphaGUARD were required of at least 500 counts, <25% of the relative percent difference. AlphaGUARD can provide accurate measurements of radon concentration for the world average level (∼50 Bq m -3 ) and the reference level of workplace (1000 Bq m -3 ), using integrated data over at least 3 h and 10 min, respectively. (authors)

  8. The boron concentration measurement by the prompt gamma-ray analysis device at JRR-4

    International Nuclear Information System (INIS)

    Hori, N.; Torii, Y.; Yamamoto, K.; Kishi, T.; Takada, J.

    2000-01-01

    In determining the dose for BNCT, it is important to measure the boron concentration in blood as well as the thermal neutron fluence. To attain an accurate measurement of the boron concentration in the whole blood at about 30 ppm, the Prompt Gamma-ray Analysis (PGA) is adopted to enable the measurement with a high degree of accuracy in short time, since the chemical analysis technique has some difficulties on it. In order to install the PGA device in a swimming pool type research reactor JRR-4, the super-mirror for obtaining the necessary neutron flux in the space over the pool surface was perpendicularly placed, because the reactor had no horizontal experiment tube for this kind of use. As the accurate measurement of the boron concentration in whole blood using PGA is enabled herewith, the first medical irradiation for BNCT at JRR-4 was carried out on October 25, 1999. (author)

  9. 41Ar-concentration measurements at the Finnish TRIGA Mark II

    International Nuclear Information System (INIS)

    Tamminen, A.

    1970-01-01

    41 Ar-concentrations in the reactor hall and in the Ar-ventilation duct of FiR-1 (IRIGA Mark II, 250 kW) have been measured during normal operation conditions. Additional measurements have been performed varying Ar-ventilation and hall ventilation flow. A γ- and background compensated thin window proportional detector and a β-Geiger detector for 41 Ar-measurements are described. The hall concentration has also been estimated from background measurements with an unshielded Ge(Li)-detector. The saturation concentration in the reactor hall with and without the hall ventilation is about 1 x 10 -7 μCi/cm 3 and 3 x 10 -7 μCi/cm 3 , respectively. (author)

  10. Estimation of Uncertainty in Aerosol Concentration Measured by Aerosol Sampling System

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Chan; Song, Yong Jae; Jung, Woo Young; Lee, Hyun Chul; Kim, Gyu Tae; Lee, Doo Yong [FNC Technology Co., Yongin (Korea, Republic of)

    2016-10-15

    FNC Technology Co., Ltd has been developed test facilities for the aerosol generation, mixing, sampling and measurement under high pressure and high temperature conditions. The aerosol generation system is connected to the aerosol mixing system which injects SiO{sub 2}/ethanol mixture. In the sampling system, glass fiber membrane filter has been used to measure average mass concentration. Based on the experimental results using main carrier gas of steam and air mixture, the uncertainty estimation of the sampled aerosol concentration was performed by applying Gaussian error propagation law. FNC Technology Co., Ltd. has been developed the experimental facilities for the aerosol measurement under high pressure and high temperature. The purpose of the tests is to develop commercial test module for aerosol generation, mixing and sampling system applicable to environmental industry and safety related system in nuclear power plant. For the uncertainty calculation of aerosol concentration, the value of the sampled aerosol concentration is not measured directly, but must be calculated from other quantities. The uncertainty of the sampled aerosol concentration is a function of flow rates of air and steam, sampled mass, sampling time, condensed steam mass and its absolute errors. These variables propagate to the combination of variables in the function. Using operating parameters and its single errors from the aerosol test cases performed at FNC, the uncertainty of aerosol concentration evaluated by Gaussian error propagation law is less than 1%. The results of uncertainty estimation in the aerosol sampling system will be utilized for the system performance data.

  11. Relating soil solution Zn concentration to diffusive gradients in thin films measurements in contaminated soils.

    Science.gov (United States)

    Degryse, Fien; Smolders, Erik; Oliver, Ian; Zhang, Hao

    2003-09-01

    The technique of diffusive gradients in thin films (DGT) has been suggested to sample an available fraction of metals in soil. The objectives of this study were to compare DGT measurements with commonly measured fractions of Zn in soil, viz, the soil solution concentration and the total Zn concentration. The DGT technique was used to measure fluxes and interfacial concentrations of Zn in three series of field-contaminated soils collected in transects toward galvanized electricity pylons and in 15 soils amended with ZnCl2 at six rates. The ratio of DGT-measured concentration to pore water concentration of Zn, R, varied between 0.02 and 1.52 (mean 0.29). This ratio decreased with decreasing distribution coefficient, Kd, of Zn in the soil, which is in agreement with the predictions of the DGT-induced fluxes in soils (DIFS) model. The R values predicted with the DIFS model were generally larger than the observed values in the ZnCl2-amended soils at the higher Zn rates. A modification of the DIFS model indicated that saturation of the resin gel was approached in these soils, despite the short deployment times used (2 h). The saturation of the resin with Zn did not occur in the control soils (no Zn salt added) or the field-contaminated soils. Pore water concentration of Zn in these soils was predicted from the DGT-measured concentration and the total Zn content. Predicted values and observations were generally in good agreement. The pore water concentration was more than 5 times underpredicted for the most acid soil (pH = 3) and for six other soils, for which the underprediction was attributed to the presence of colloidal Zn in the soil solution.

  12. Method to make accurate concentration and isotopic measurements for small gas samples

    Science.gov (United States)

    Palmer, M. R.; Wahl, E.; Cunningham, K. L.

    2013-12-01

    Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.

  13. Use of 15N Natural Abundance and N Species Concentrations to Assess N-Cycling in Constructed and Natural Coastal

    International Nuclear Information System (INIS)

    Aelion, W.C.M.; Engle, M.R.; Aelion, W.C.M.; Ma, H.

    2010-01-01

    Natural abundance of N stable isotopes used in combination with concentrations may be useful indicators of N-cycling in wetlands. Concentrations and 15 N signatures of NO 3 -, NH 4 and sediment organic nitrogen (SON) were measured in two impacted coastal golf course retention ponds and two natural marshes. Limited NO 3 was detected in natural site surface water or pore water, but both isotopic signature and concentrations of NO 3 - in surface water of impacted sites indicated anthropogenic inputs. In natural sites, NH 4 concentrations were greatest in deeper pore water and least in surface water, suggesting diffusion predominates. The natural sites had greater % SON, and 15 N indicated that the natural sites also had greater NH 4 + released from SON mineralization than impacted sites. In NO 3 --limited systems, neither concentrations nor 15 N natural abundance was able to provide information on N-cycling, while processes associated with NH 4 + were better elucidated by using both concentrations and 15 N natural abundance

  14. Use of N Natural Abundance and N Species Concentrations to Assess N-Cycling in Constructed and Natural Coastal Wetlands

    Directory of Open Access Journals (Sweden)

    C. Marjorie Aelion

    2010-01-01

    Full Text Available Natural abundance of N stable isotopes used in combination with concentrations may be useful indicators of N-cycling in wetlands. Concentrations and N signatures of NO3−, NH4+, and sediment organic nitrogen (SON were measured in two impacted coastal golf course retention ponds and two natural marshes. Limited NO3− was detected in natural site surface water or pore water, but both isotopic signature and concentrations of NO3− in surface water of impacted sites indicated anthropogenic inputs. In natural sites, NH4+ concentrations were greatest in deeper pore water and least in surface water, suggesting diffusion predominates. The natural sites had greater %SON, and N indicated that the natural sites also had greater NH4+ released from SON mineralization than impacted sites. In NO3−-limited systems, neither concentrations nor N natural abundance was able to provide information on N-cycling, while processes associated with NH4+ were better elucidated by using both concentrations and N natural abundance.

  15. Elastic Stability of Concentric Tube Robots: A Stability Measure and Design Test.

    Science.gov (United States)

    Gilbert, Hunter B; Hendrick, Richard J; Webster, Robert J

    2016-02-01

    Concentric tube robots are needle-sized manipulators which have been investigated for use in minimally invasive surgeries. It was noted early in the development of these devices that elastic energy storage can lead to rapid snapping motion for designs with moderate to high tube curvatures. Substantial progress has recently been made in the concentric tube robot community in designing snap-free robots, planning stable paths, and characterizing conditions that result in snapping for specific classes of concentric tube robots. However, a general measure for how stable a given robot configuration is has yet to be proposed. In this paper, we use bifurcation and elastic stability theory to provide such a measure, as well as to produce a test for determining whether a given design is snap-free (i.e. whether snapping can occur anywhere in the unloaded robot's workspace). These results are useful in designing, planning motions for, and controlling concentric tube robots with high curvatures.

  16. Evanescent Wave Absorption Based Fiber Sensor for Measuring Glucose Solution Concentration

    Science.gov (United States)

    Marzuki, Ahmad; Candra Pratiwi, Arni; Suryanti, Venty

    2018-03-01

    An optical fiber sensor based on evanescent wave absorption designed for measuring glucose solution consentration was proposed. The sensor was made to detect absorbance of various wavelength in the glucose solution. The sensing element was fabricated by side polishing of multimode polymer optical fiber to form a D-shape. The sensing element was immersed in different concentration of glucoce solution. As light propagated through the optical fiber, the evanescent wave interacted with the glucose solution. Light was absorbed by the glucose solution. The larger concentration the glucose solution has, the more the evanescent wave was absorbed in particular wavelenght. Here in this paper, light absorbtion as function of glucose concentration was measured as function of wavelength (the color of LED). We have shown that the proposed sensor can demonstrated an increase of light absorption as function of glucose concentration.

  17. Measurements of the size dependence of the concentration of nonvolatile material in fog droplets

    Science.gov (United States)

    Ogren, J. A.; Noone, K. J.; Hallberg, A.; Heintzenberg, J.; Schell, D.; Berner, A.; Solly, I.; Kruisz, C.; Reischl, G.; Arends, B. G.; Wobrock, W.

    1992-11-01

    Measurements of the size dependence of the mass concentration of nonvolatile material dissolved and suspended in fog droplets were obtained with three complementary approaches, covering a size range from c. 1 50µm diameter: a counterflow virtual impactor, an eight-stage aerosol impactor, and a two-stage fogwater impactor. Concentrations were observed to decrease with size over the entire range, contrary to expectations of increasing concentrations at larger sizes. It is possible that the larger droplets had solute concentrations that increased with increasing size, but that the increase was too weak for the measurements to resolve. Future studies should consider the hypothesis that the droplets were coated with a surface-active substance that hindered their uptake of water.

  18. The effect of the nuclear track detectors' position on the radon concentration measurements

    International Nuclear Information System (INIS)

    Yilmaz, A.; Kuerkcueoglu, M. E.; Haner, B.

    2009-01-01

    It is important to determine the radon concentration values of the underground mines according to workers' health. For this purpose, to be able to measure radon concentrations by using passive nuclear etched track detectors, CR-39 detectors were placed into 66 points on the way of aeration galleries of Armutcuk, Amasra, Karadon, Kozlu and Uezuelmez bituminous coal mines which are known as the Carboniferous outcrops of the Western Black Sea Area in Turkey. In every measurement point, a pair of detectors, one of them is being perpendicular and the other one is parallel to air flow, were exposed to radon gases over 40 days for four seasons of the year 2008. The relationship between the readings of vertically and horizontally positioned detectors was investigated by evaluating the effect of the detectors' positions on the detected radon concentrations. It can be concluded that, the vertically positioned detectors, in general, recorded higher radon gases concentration values than that of the horizontally positioned ones.

  19. Measurement of radon progeny concentrations in air by alpha-particle spectrometey

    International Nuclear Information System (INIS)

    Kerr, G.D.

    1975-07-01

    A technique is presented for measuring air concentrations of the short-lived progeny of radon-222 by the use of alpha spectrometry. In this technique, the concentration of RaA, RaB, and RaC are calculated from one integral count of the RaA and two integral counts of the RaC' alpha-particle activity collected on a filter with an air sampling device. The influence of air sampling and counting intervals of time on the accuracy of the calculated concentrations is discussed in the report. A computer program is presented for use with this technique. It is written in the BASIC language. The program will calculate the air concentrations of RaA, RaB, and RaC, and will estimate the accuracy in these calculated concentrations. (U.S.)

  20. Comparison of Respirable Mass Concentrations Measured by a Personal Dust Monitor and a Personal DataRAM to Gravimetric Measurements.

    Science.gov (United States)

    Halterman, Andrew; Sousan, Sinan; Peters, Thomas M

    2017-12-15

    In 2016, the Mine Safety and Health Administration required the use of continuous monitors to measure respirable dust in mines and better protect miner health. The Personal Dust Monitor, PDM3700, has met stringent performance criteria for this purpose. In a laboratory study, respirable mass concentrations measured with the PDM3700 and a photometer (personal DataRam, pDR-1500) were compared to those measured gravimetrically for five aerosols of varying refractive index and density (diesel exhaust fume, welding fume, coal dust, Arizona road dust (ARD), and salt [NaCl] aerosol) at target concentrations of 0.38, 0.75, and 1.5 mg m-3. For all aerosols except coal dust, strong, near-one-to-one, linear relationships were observed between mass concentrations measured with the PDM3700 and gravimetrically (diesel fume, slope = 0.99, R2 = 0.99; ARD, slope = 0.98, R2 = 0.99; and NaCl, slope = 0.95, R2 = 0.99). The slope deviated substantially from unity for coal dust (slope = 0.55; R2 = 0.99). Linear relationships were also observed between mass concentrations measured with the pDR-1500 and gravimetrically, but one-to-one behavior was not exhibited (diesel fume, slope = 0.23, R2 = 0.76; coal dust, slope = 0.54, R2 = 0.99; ARD, slope = 0.61, R2 = 0.99; NaCl, slope = 1.14, R2 = 0.98). Unlike the pDR-1500, mass concentrations measured with the PDM3700 appear independent of refractive index and density, suggesting that it could have applications in a variety of occupational settings. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  1. PET measurement of FK506 concentration in a monkey model of stroke

    International Nuclear Information System (INIS)

    Murakami, Yoshihiro; Takamatsu, Hiroyuki; Noda, Akihiro; Osoda, Kazuhiko; Nishimura, Shintaro

    2007-01-01

    Introduction: The immunosuppressive agent FK506 (tacrolimus) has neuroprotective properties in an experimental model of cerebral ischemia. To improve the accuracy of clinical studies in acute stroke, a clinical dose setting should be based on the brain concentration, but not on the blood concentration of agents in humans. We have already established a measurement method using PET for FK506 concentration in the normal monkey brain, which could be applicable for human study; however, under ischemic conditions, in this study, we aimed to examine the brain concentration of FK506 in a monkey model of stroke. Methods: Studies were performed on six male cynomolgus monkeys (Macaca fascicularis) and a middle cerebral artery (MCA) occlusion model was used. Regional cerebral blood flow (rCBF) was measured by an intravenous injection of [ 15 O]H 2 O 165 min after MCA occlusion. FK506 (0.1 mg/kg) containing [ 11 C]FK506 was intravenously injected into the monkeys 180 min after MCA occlusion, and dynamic PET images were acquired for 30 min after administration. FK506 concentrations in the brain were calculated in moles per liter (M) units using the specific activity of injected FK506. Results: MCA occlusion produced ischemia, confirmed by rCBF measurement before the administration of [ 11 C]FK506. Fifteen minutes after FK506 (0.1 mg/kg) administration, the concentrations in the contralateral and ipsilateral cortex were 22.4±6.4 and 19.7±4.0 ng/g, respectively. Conclusion: We successfully measured the brain concentration of FK506 in a monkey model of stroke. The difference between the contralateral and ipsilateral concentrations of FK506 was not significant. This characteristic that FK506 readily penetrates ischemic tissue as well as normal tissue might explain the neuroprotective effect of FK506 in the ischemic brain and is suitable for the treatment of stroke patients

  2. Development of a 10 Hz measurement system for atmospheric aerosol concentration

    International Nuclear Information System (INIS)

    Bouarouri, Assia

    2014-01-01

    The goal is to develop an aerosol charger based on a corona discharge for atmospheric concentration measurements (10 3 -10 5 cm -3 ) within a response time of 100 ms. Two ion sources, point-to-hole and wire-to-slit have been characterized. The increase of the ion flow in the post-discharge by EHD ion confinement in both the discharge gap and the hole has been shown. At first, using an experimental survey driven in two mixing configurations, concentric and face-to-face, we have confirmed the aerosol diffusion charging law which depends on aerosol diameter and N i .t product, with N i , the ions concentration and t, the charging time. Thus, the originality of this charger relies on the very high heterogeneity of unipolar ion densities (N i 0 ≥10 9 cm -3 ) required to compensate the charging time of 50 ms. In these conditions, we have shown that aerosol diameter and the charging dynamic (which depends also on the diameter) control the aerosol trajectory. The chargers have, next, been compared in different operating conditions, mainly in terms of the maximal charging and the minimal losses. In the chosen charger (point-to-hole ion source and concentric mixing), the relations charge/mobility and losses according to diameter have been characterized. We have also shown the linearity of the charged particles current with the aerosol concentration which allows the current-concentration data inversion. The preliminary measurement system composed by the charger, the separator and the particle current measurements, satisfies the objectives of the study in terms of the concentration detection limit (10 3 cm -3 ) and the response time (100 ms). We have thus shown the feasibility of an atmospheric aerosol concentration measurement system at 10 Hz using a corona discharge charger provided that the separation power is improved. Furthermore, knowing that aerosol losses are negligible and the lower limit of the partial charging, the developed charger is adaptable with other

  3. Integrated Microanalytical System for Simultaneous Voltammetric Measurements of Free Metal Ion Concentrations in Natural Waters

    OpenAIRE

    Noël, Stéphane; Tercier-Waeber, Mary-Lou; Lin, Lin; Buffle, Jacques; Guenat, Olivier; Koudelka-Hep, Milena

    2007-01-01

    A complexing gel integrated microelectrode (CGIME) for direct measurements of free metal ion concentrations in natural waters has been developed. It is prepared by the successive deposition of microlayers of a chelating resin, an antifouling agarose gel and Hg on a 100-interconnected Ir-based microelectrode array. The trace metals of interest are in a first step accumulated on the chelating resin in proportion to their free ion concentration in solution, then released in acidic solution and d...

  4. The measurement of thoron (220Rn) concentration in indoor air continuously using pylon model WLx

    International Nuclear Information System (INIS)

    Hasnel Sofyan

    2011-01-01

    The concentration of thoron ( 220 Rn) in particular location can be higher than radon ( 220 Rn), however, its presence is always neglected. This might be due to the difficulties in calibration and discrimination between radon and thoron. From biokinetic and dosimetric model, it has been known that the dominant contribution of thoron to the effective dose is in the lungs. UNSCEAR estimates the doses contribution of thoron and its progenies is between 5-10% of the annual dose received by the general public and the risk level is 4.4 times greater than radon and progenies. Therefore, it is necessary to study the thoron concentration in indoor air and workplaces. Radon-thoron concentration in indoor air can be determined by direct methods using Pylon Model WLx device and passive methods using Solid State Nuclear Track Detector (SSNTDs). In this research the measurement of thoron was carried out continuously using Pylon Model WLx equipment that is sensitive to radon for 24, 65, 72, 116 and 154 hours in different rooms. The measurement result showed that the mean value of thoron working level (WL) concentration obtained in room-1 was 2.53 ± 0.67 Bq/m 3 with maximum and minimum of thoron concentrations were 3.37 and 2.22 Bq/m 3 respectively. From the measurement in different locations, it was obtained that the largest and smallest average concentrations of thoron progenies were 0.83 ± 0.23 Bq/m 3 and 0.29 ± 0.64 Bq/m 3 , while the maximum and minimum concentration values were 7.80 Bq/m 3 and 0.01 Bq/m 3 respectively. Pylon Model WLx device is not enables to be used for longer and large scale survey area concurrently, so the SSNTDs which is sensitive to the emission of alpha particles and can measure cumulative thoron concentrations is required. (author)

  5. Evaluating the reliability of uranium concentration and isotope ratio measurements via an interlaboratory comparison program

    International Nuclear Information System (INIS)

    Oliveira Junior, Olivio Pereira de; Oliveira, Inez Cristina de; Pereira, Marcia Regina; Tanabe, Eduardo

    2009-01-01

    The nuclear fuel cycle is a strategic area for the Brazilian development because it is associated with the generation of electricity needed to boost the country economy. Uranium is one the chemical elements in this cycle and its concentration and isotope composition must be accurately known. In this present work, the reliability of the uranium concentration and isotope ratio measurements carried out at the CTMSP analytical laboratories is evaluated by the results obtained in an international interlaboratory comparison program. (author)

  6. Direct concentration and viability measurement of yeast in corn mash using a novel imaging cytometry method.

    Science.gov (United States)

    Chan, Leo L; Lyettefi, Emily J; Pirani, Alnoor; Smith, Tim; Qiu, Jean; Lin, Bo

    2011-08-01

    Worldwide awareness of fossil-fuel depletion and global warming has been increasing over the last 30 years. Numerous countries, including the USA and Brazil, have introduced large-scale industrial fermentation facilities for bioethanol, biobutanol, or biodiesel production. Most of these biofuel facilities perform fermentation using standard baker's yeasts that ferment sugar present in corn mash, sugar cane, or other glucose media. In research and development in the biofuel industry, selection of yeast strains (for higher ethanol tolerance) and fermentation conditions (yeast concentration, temperature, pH, nutrients, etc.) can be studied to optimize fermentation performance. Yeast viability measurement is needed to identify higher ethanol-tolerant yeast strains, which may prolong the fermentation cycle and increase biofuel output. In addition, yeast concentration may be optimized to improve fermentation performance. Therefore, it is important to develop a simple method for concentration and viability measurement of fermenting yeast. In this work, we demonstrate an imaging cytometry method for concentration and viability measurements of yeast in corn mash directly from operating fermenters. It employs an automated cell counter, a dilution buffer, and staining solution from Nexcelom Bioscience to perform enumeration. The proposed method enables specific fluorescence detection of viable and nonviable yeasts, which can generate precise results for concentration and viability of yeast in corn mash. This method can provide an essential tool for research and development in the biofuel industry and may be incorporated into manufacturing to monitor yeast concentration and viability efficiently during the fermentation process.

  7. Concentrations of OH and HO2 radicals during NAMBLEX: measurements and steady state analysis

    Directory of Open Access Journals (Sweden)

    S. C. Smith

    2006-01-01

    Full Text Available OH and HO2 concentrations were measured simultaneously at the Mace Head Atmospheric Research Station in the summer of 2002 during the NAMBLEX (North Atlantic Marine Boundary Layer EXperiment field campaign. OH was measured by laser-induced fluorescence employing the FAGE (Fluorescence Assay by Gas Expansion technique, with a mean daytime detection limit of 2.7×105 molecule cm−3 (5 min acquisition period; signal-to-noise ratio = 1. HO2 was detected as OH following its chemical conversion through addition of NO, with a mean detection limit of 4.4×106 molecule cm−3. The diurnal variation of OH was measured on 24 days, and that of HO2 on 17 days. The local solar noon OH concentrations ranged between (3–8×106 molecule cm−3, with a 24 h mean concentration of 9.1×105 molecule cm−3. The local solar noon HO2 concentrations were (0.9–2.1×108 molecule cm−3 (3.5–8.2 pptv, with a 24 h mean concentration of 4.2×107 molecule cm−3 (1.6 pptv. HO2 radicals in the range (2–3×107 molecule cm−3 were observed at night. During NAMBLEX, a comprehensive suite of supporting measurements enabled a detailed study of the behaviour of HOx radicals under primarily clean marine conditions. Steady state expressions are used to calculate OH and HO2 concentrations and to evaluate the effect of different free-radical sources and sinks. The diurnally averaged calculated to measured OH ratio was 1.04±0.36, but the ratio displays a distinct diurnal variation, being less than 1 during the early morning and late afternoon/evening, and greater than 1 in the middle of the day. For HO2 there was an overprediction, with the agreement between calculated and measured concentrations improved by including reaction with measured IO and BrO radicals and uptake to aerosols. Increasing the concentration of IO radicals included in the calculations to above that measured by a DOAS instrument with an absorption path located mainly over the ocean, reflecting the

  8. Dissolved oxygen concentration profiles in the hyporheic zone through the use of a high density fiber optic measurement network

    Science.gov (United States)

    Reeder, W. J.; Quick, A. M.; Farrell, T. B.; Benner, S. G.; Feris, K. P.; Tonina, D.

    2013-12-01

    The hyporheic zone (HZ) is a potentially important source of the potent greenhouse gas, nitrous oxide (N2O); stream processes may account for up to 10% of global anthropogenic N2O emissions. However, mechanistic understanding and predictive quantification of this gas flux is hampered by complex temporally and spatially variable interactions between flow dynamics and biogeochemical processes. Reactive inorganic nitrogen (Nr) is typically present at low concentrations in natural stream waters, but many rural and urban streams suffer from an excess of Nr, typically in the form of ammonium (NH4+) and nitrate (NO3-). These reactive species are either assimilated by living biomass or transformed by microbial processes. The two primary microbial transformations of Nr are nitrification (NH4+ to NO3-) and denitrification (NO3- to N2). Denitrification, which occurs almost exclusively in the anoxic zone of the HZ, permanently removes between 30-70% of all Nr entering streams, other mechanisms may retain nitrogen. The mass transport of reactive species (i.e. O2, NO3- and N2O) by hyporheic flow strongly influences reaction rates, residence times, and subsequent N2O flux. By extension, stream flow and channel morphology presumably control, and may be effective predictors of, N2O generation rates. By recreating the stream processes in the University of Idaho flume, we are able to control the bed morphology, fluxes and residence times through the HZ and concentrations of Nr from exogenous (stream water) and endogenous (organic material in the streambed) sources. For the present experiment, the flume was divided into three streams, each with different morphologies (3, 6 and 9cm dunes) and all using the same source water. Stream water for this first experimental phase had no significant loading of Nr. As such, all reaction products were the result of endogenous sources of Nr. To measure dissolved oxygen (DO) concentrations we deployed 120 channels of a novel, fiber-optic optode

  9. Atmospheric alcohols and aldehydes concentrations measured in Osaka, Japan and in Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Nguyen, Ha Thi-Hoang; Takenaka, Norimichi; Bandow, Hiroshi; Maeda, Yasuaki; Oliva, S.T. de; Botelho, M.M.; Tavares, T.M.

    2001-01-01

    The use of alcohol fuel has received much attention since the 1980s. In Brazil, ethanol-fuelled vehicles have been currently used on a large scale. This paper reports the atmospheric methanol and isoproponal concentrations which were measured from May to December 1997, in Osaka, Japan, where alcohol fuel was not used and from 3 to 9 February 1998 in Sao Paulo, Brazil, where ethanol was used. The alcohols were determined by the alkyl nitrite formation reaction using gas chromatography (GC-ECD) analysis. The concentration of atmospheric alcohols, especially ethanol, measured in Sao Paulo were significantly higher than those in Osaka. In Osaka, the average concentrations of atmospheric methanol, ethanol, and isopropanol were 5.8 ± 3.8, 8.2 ± 4.6, and 7.2 ± 5.9ppbv, respectively. The average ambient levels of methanol, ethanol, and isopropanol measured in Sao Paulo were 34.1± 9.2, 176.3 ± 38.1, and 44.2 ± 13.7ppbv, respectively. The ambient levels of aldehydes, which were expected to be high due to the use of alcohol fuel, were also measured at these sampling sites. The atmospheric formaldehyde average measured in Osaka was 1.9± 0.9ppbv, and the average acetaldehyde concentration was 1.5 ± 0.8ppbv. The atmospheric formaldehyde and acetaldehyde average concentrations measured in Sao Paulo were 5.0 ± 2.8 and 5.4 ± 2.8ppbv, respectively. The C 2 H 5 OH/CH 3 OH and CH 3 CHO/HCHO were compared between the two measurement sites and elsewhere in the world, which have already been reported in the literature. Due to the use of ethanol-fuelled vehicles, these ratios, especially C-2H 5 OH/CH 3 OH, are much higher in Brazil than those measured elsewhere in the world. (Author)

  10. On-chip measurements of Brownian relaxation vs. concentration of 40nm magnetic beads

    DEFF Research Database (Denmark)

    Østerberg, Frederik Westergaard; Rizzi, Giovanni; Hansen, Mikkel Fougt

    2012-01-01

    We present on-chip Brownian relaxation measurements on a logarithmic dilution series of 40 nm beads dispersed in water with bead concentrations between 16 mu g/ml and 4000 mu g/ml. The measurements are performed using a planar Hall effect bridge sensor at frequencies up to 1 MHz. No external fields...... are needed as the beads are magnetized by the field generated by the applied sensor bias current. We show that the Brownian relaxation frequency can be extracted from fitting the Cole-Cole model to measurements for bead concentrations of 64 mu g/ml or higher and that the measured dynamic magnetic response...... is proportional to the bead concentration. For bead concentrations higher than or equal to 500 mu g/ml, we extract a hydrodynamic diameter of 47(1) nm for the beads, which is close to the nominal bead size of 40 nm. Furthermore, we study the signal vs. bead concentration at a fixed frequency close to the Brownian...

  11. Experimental Determination of Drug Diffusion Coefficients in Unstirred Aqueous Environments by Temporally Resolved Concentration Measurements

    DEFF Research Database (Denmark)

    Di Cagno, Massimiliano Pio; Clarelli, Fabrizio; Vabenø, Jon

    2018-01-01

    or the need for dedicated instrumentation. In this work, a simple but reliable method based on time resolved concentration measurements by UV-visible spectroscopy in an unstirred aqueous environment was developed. This method is based on spectroscopic measurement of the variation of the local concentration...... characteristics (i.e. ionic strength and presence of complexing agents) on the diffusivity. The method can be employed in any research laboratory equipped with a standard UV-visible spectrophotometer, and could become a useful and straightforward tool in order to characterize diffusion coefficients...

  12. Measurement of thyroid volume, iodine concentration and total iodine content by CT and its clinical significance

    International Nuclear Information System (INIS)

    Nakaji, Shunsuke; Imanishi, Yoshimasa; Okamoto, Kyouko; Shinagawa, Toshihito

    2007-01-01

    Recently, Imanishi et al have developed new CT software for quantitative in vivo measurement of thyroid iodine. Using a CT system with the software, we measured volume, iodine concentration and total iodine content of thyroids in 63 controls and 435 patients with various diffuse thyroid diseases and thyroid nodules. In controls, all of them showed no difference between the sexes. Although the iodine concentration of the thyroid showed no difference among children, adults and seniles, the volume and total iodine content of the thyroid appeared smaller in children and seniles than in adults. In addition, although the volume and iodine concentration of the thyroid had two peaks in distribution, the total iodine content had almost normal distribution. Normal range of volume, iodine concentration and total iodine content in adults were 5.2-15.5 cm 3 , 0.28831-0.85919 mg/cm 3 and 2.35-11.69 mg, respectively. In thyroid nodule, there is no significant difference in volume, iodine concentration and total iodine content between benign and malignant nodules. All nodules with iodine concentration of less than 0.00007 mg/cm 3 were benign. No thyroid was higher in iodine concentration than the normal range although the thyroid was lower in 78.7% of patients with diffuse thyroid diseases. In all thyroids with increasing iodine concentration and total iodine content in medication course, thyroidal symptoms and signs were uncontrollable by the medication. In 43.8% of patients with long-period systemic diseases, the thyroid showed abnormality in any of the three. We concluded that quantitative in vivo measurement of thyroid iodine by CT could assist the diagnosis of thyroid diseases and decision of therapeutic methods. (author)

  13. Eimeria Oocyst Concentrations and Species Composition in Litter from Commercial Broiler Farms During Anticoccidial Drug or Live Eimeria Oocyst Vaccine Control Programs.

    Science.gov (United States)

    Jenkins, Mark C; Parker, Carolyn; Ritter, Donald

    2017-06-01

    The purpose of this study was to determine if Eimeria oocyst concentrations and species composition in commercial broiler house litter changed during different cycles of anticoccidial drug (ACD) or live Eimeria oocyst vaccine (VAC) control programs and if there was a correlation between Eimeria oocyst levels and broiler performance. Litter samples were collected from a total of 15 different broiler farms encompassing a total of 45 individual houses during at least one complete grow-out cycle over a 21-mo period. Of these 15 broiler farms, three were followed for the entire 21-mo period spanning three ACD and four VAC cycles. Samples were collected at 2, 4, and 7-8 wk of grow-out corresponding to starter, grower, and withdraw periods of the ACD cycle. On a number of occasions, litter samples were obtained just prior to chick placement. Eimeria oocysts were isolated from all samples, counted by microscopy, and extracted for DNA to identify Eimeria species by ITS1 PCR. In general, Eimeria oocyst concentration in litter reached peak levels at 2-4 wk of grow-out regardless of coccidiosis control measure being used. However, peak oocyst numbers were sometimes delayed until 7-8 wk, indicating some level of Eimeria spp. drug resistance or incomplete vaccine coverage. Eimeria maxima , Eimeria acervulina , Eimeria praecox, and Eimeria tenella were generally present in all samples, and no difference in the species composition was noted between houses on a particular farm. While Eimeria species composition was similar among houses, Eimeria spp. oocyst levels exhibited sporadic peaks in one house of a given location's houses. Of particular interest was the observed correlation between E. maxima oocyst abundance and chick mortality. However, no correlation was observed in E. maxima oocyst levels, and the performance parameters adjusted feed conversion ratio and average daily weight gain. This study showed that understanding the dynamics of Eimeria spp. oocyst levels and species

  14. Windows pollution problems of the dust concentration measurement based on scattering method

    International Nuclear Information System (INIS)

    Zhao Yanjun; Zhang Yongtao; Shi Xinyue; Xu Chuanlong; Wang Shimin

    2009-01-01

    The windows are separated the measurement system from the dust space in the light Scattering dust concentration measurement system. The windows are polluted unavoidably by the dust and the measurement error is produced. Based on the Mie Scattering theory, the measurement error is researched in this paper. The numerical simulation results show that the measurement error is related to the particles diameter distribution and the refractive index, but is independent of the particles average diameter. A novel photoelectricity sensor is developed in this paper in order to solve the measurement error by the windows pollution. The calculated method is brought out which can amend the measurement errors by the windows pollution and improve the measurement accuracy.

  15. Effect of depositional environment and sources of pollution on uranium concentration in sediment, coral, algae and seagrass species from the Gulf of Aqaba (Red Sea)

    International Nuclear Information System (INIS)

    Abu-Hilal, A.H.

    1994-01-01

    Uranium concentrations were determined in sediment samples, four hard and two soft corals, one seagrass and four species of algae collected from phosphate-polluted sites in the northern reef area of the Gulf of Aqaba. High uranium concentrations were found in all samples examined from a phosphate-polluted site near a phosphate loading berth compared to the unpolluted ones. Uranium levels, U/Ca ratios, concentration and discrimination factors were also high compared to those reported from other regions of the world. The effects of the exported raw phosphate powder as the main source of pollution and depositional environment on the concentration of uranium in the examined species are discussed. (Author)

  16. Measurements of salivary alpha amylase and salivary cortisol in hominoid primates reveal within-species consistency and between-species differences.

    Directory of Open Access Journals (Sweden)

    Verena Behringer

    Full Text Available Salivary alpha amylase (sAA is the most abundant enzyme in saliva. Studies in humans found variation in enzymatic activity of sAA across populations that could be linked to the copy number of loci for salivary amylase (AMY1, which was seen as an adaptive response to the intake of dietary starch. In addition to diet dependent variation, differences in sAA activity have been related to social stress. In a previous study, we found evidence for stress-induced variation in sAA activity in the bonobos, a hominoid primate that is closely related to humans. In this study, we explored patterns of variation in sAA activity in bonobos and three other hominoid primates, chimpanzee, gorilla, and orangutan to (a examine if within-species differences in sAA activity found in bonobos are characteristic for hominoids and (b assess the extent of variation in sAA activity between different species. The results revealed species-differences in sAA activity with gorillas and orangutans having higher basal sAA activity when compared to Pan. To assess the impact of stress, sAA values were related to cortisol levels measured in the same saliva samples. Gorillas and orangutans had low salivary cortisol concentrations and the highest cortisol concentration was found in samples from male bonobos, the group that also showed the highest sAA activity. Considering published information, the differences in sAA activity correspond with differences in AMY1 copy numbers and match with general features of natural diet. Studies on sAA activity have the potential to complement molecular studies and may contribute to research on feeding ecology and nutrition.

  17. Egg-laying sequence influences egg mercury concentrations and egg size in three bird species: Implications for contaminant monitoring programs.

    Science.gov (United States)

    Ackerman, Joshua T; Eagles-Smith, Collin A; Herzog, Mark P; Yee, Julie L; Hartman, C Alex

    2016-06-01

    Bird eggs are commonly used in contaminant monitoring programs and toxicological risk assessments, but intraclutch variation and sampling methodology could influence interpretability. The authors examined the influence of egg-laying sequence on egg mercury concentrations and burdens in American avocets, black-necked stilts, and Forster's terns. The average decline in mercury concentrations between the first and last eggs laid was 33% for stilts, 22% for terns, and 11% for avocets, and most of this decline occurred between the first and second eggs laid (24% for stilts, 18% for terns, and 9% for avocets). Trends in egg size with egg-laying order were inconsistent among species, and overall differences in egg volume, mass, length, and width were eggs laid. Despite the strong effect of egg-laying sequence, most of the variance in egg mercury concentrations still occurred among clutches (75-91%) rather than within clutches (9%-25%). Using simulations, the authors determined that accurate estimation of a population's mean egg mercury concentration using only a single random egg from a subset of nests would require sampling >60 nests to represent a large population (10% accuracy) or ≥14 nests to represent a small colony that contained <100 nests (20% accuracy). Environ Toxicol Chem 2016;35:1458-1469. Published 2015 Wiley Periodicals Inc. on behalf of SETAC. This article is a US Government work and, as such, is in the public domain in the United States of America. Published 2015 Wiley Periodicals Inc. on behalf of SETAC. This article is a US Government work and, as such, is in the public domain in the United States of America.

  18. Oxidative stress and antioxidant responses to increasing concentrations of trivalent chromium in the Andean crop species Chenopodium quinoa Willd.

    Science.gov (United States)

    Scoccianti, Valeria; Bucchini, Anahi E; Iacobucci, Marta; Ruiz, Karina B; Biondi, Stefania

    2016-11-01

    Quinoa (Chenopodium quinoa Willd), an ancient Andean seed crop, exhibits exceptional nutritional properties and resistance to abiotic stress. The species' tolerance to heavy metals has, however, not yet been investigated nor its ability to take up and translocate chromium (Cr). This study aimed to investigate the metabolic adjustments occurring upon exposure of quinoa to several concentrations (0.01-5mM) of CrCl3. Young hydroponically grown plants were used to evaluate Cr uptake, growth, oxidative stress, and other biochemical parameters three and/or seven days after treatment. Leaves accumulated the lowest amounts of Cr, while roots and stems accumulated the most at low and at high metal concentrations, respectively. Fresh weight and photosynthetic pigments were reduced only by the higher Cr(III) doses. Substantially increased lipid peroxidation, hydrogen peroxide, and proline levels were observed only with 5mM Cr(III). Except for a significant decrease at day 7 with 5mM Cr(III), total polyphenols and flavonoids maintained control levels in Cr(III)-treated plants, whereas antioxidant activity increased in a dose-dependent manner. Maximum polyamine accumulation was observed in 1mM CrCl3-treated plants. Even though α- and γ-tocopherols also showed enhanced levels only with the 1mM concentration, tyrosine aminotransferase (TAT, EC 2.6.1.5) activity increased under Cr(III) treatment in a dose- and time-dependent manner. Taken together, results suggest that polyamines, tocopherols, and TAT activity could contribute to tolerance to 1mM Cr(III), but not to the highest concentration that, instead, generated oxidative stress. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Ambient concentrations of aldehydes in relation to Beijing Olympic air pollution control measures

    Science.gov (United States)

    Gong, J. C.; Zhu, T.; Hu, M.; Zhang, L. W.; Cheng, H.; Zhang, L.; Tong, J.; Zhang, J.

    2010-08-01

    Aldehydes are ubiquitous constituents of the atmosphere. Their concentrations are elevated in polluted urban atmospheres. The present study was carried out to characterize three aldehydes of most health concern (formaldehyde, acetaldehyde, and acrolein) in a central Beijing site in the summer and early fall of 2008 (from June to October). Measurements were made before, during, and after the Beijing Olympics to examine whether the air pollution control measures implemented to improve Beijing's air quality during the Olympics had any impact on concentrations of the three aldehydes. Average concentrations of formaldehyde, acetaldehyde and acrolein were 29.34 ± 15.12 μg/m3, 27.09 ± 15.74 μg/m3 and 2.32 ± 0.95 μg/m3, respectively, for the entire period of measurements, all being the highest among the levels measured in cities around the world in photochemical smog seasons. Among the three measured aldehydes, only acetaldehyde had a substantially reduced mean concentration during the Olympic air pollution control period compared to the pre-Olympic period. Formaldehyde and acrolein followed the changing pattern of temperature and were each significantly correlated with ozone (a secondary product of photochemical reactions). In contrast, acetaldehyde was significantly correlated with several pollutants emitted mainly from local emission sources (e.g., NO2, CO, and PM2.5). These findings suggest that local direct emissions had a larger impact on acetaldehyde than formaldehyde and acrolein.

  20. Feasibility of Uranium Concentration Measurements for H Canyon Tank 16.7

    International Nuclear Information System (INIS)

    Lascola, R.J.

    2003-01-01

    Savannah River Technology Center (SRTC) evaluated the feasibility of using the H Canyon on-line diode array spectrophotometer to measure uranium concentrations in Tank 16.7. On-line measurements will allow an increase in highly enriched uranium (HEU) production by removing delays associated with off-line measurements. The instrument must be able to measure uranium at concentrations below 1.0 g/L with an uncertainty no greater than 0.3 g/L. SRTC determined that the system has a limit of quantitation of 0.15 g/L. At concentrations of 0.5 and 1.0 g/L, the spectrometer uncertainty is 0.10 g/L. No design changes, such as an increase in flow cell path length, are required to obtain this performance. Expected levels of iron in Tank 16.7 solutions will not interfere with the measurement. The CHEMCHEK method should not be used for confirmatory analysis, as it contributes excessively to the overall uncertainty of the measurement. SRTC expects that the spectrophotometer will meet the measurement requirements for Tank 16.7

  1. On the Usage of Cyclic Voltammetry and Impedance Spectroscopy for Measuring the Concentration of Aqueous Solutions

    Directory of Open Access Journals (Sweden)

    Manuel Fiedler

    2015-02-01

    Full Text Available This article describes sensors for concentration measurement based on the electro- chemical properties of the liquid being measured. Herein two electrical methods, namely cyclic voltammetry and impedance spectroscopy, are being presented. The measurement can be performed quasi simultaneously using the same measurement medium. Further optimization of the combined methods is possible by adapting the geometric design of the electrode structure, the electrode material, the optional passivation and the electric coupling (galvanically or capacitively. In summary, by combining multiple sensory principles on a device it becomes possible to analyze mixtures of substances contained in a solution with respect to their composition.

  2. The design and realization of calibration apparatus for measuring the concentration of radon in three models

    Energy Technology Data Exchange (ETDEWEB)

    Huiping, Guo [The Second Artillery Engineering College, Xi' an (China)

    2007-06-15

    For satisfying calibration request of radon measure in the laboratory, the calibration apparatus for radon activity measure is designed and realized. The calibration apparatus can auto-control and auto-measure in three models. sequent mode, pulse mode and constant mode. The stability and reliability of the calibration apparatus was tested under the three models. The experimental result shows that the apparatus can provides an adjustable and steady radon activity concentration environment for the research of radon and its progeny and for the calibration of its measure. (authors)

  3. Measurement of indoor radon Concentrations in Osaka, Nara, Wakayama and Hyogo with passive dosemeters

    International Nuclear Information System (INIS)

    Mori, Toshiaki; Hori, Yasuharu; Takeda, Atsuhiko; Iwasaki, Tamiko; Uchiyama, Masahumi; Fujimoto, Kenzo; Kankura, Takako; Kobayashi, Sadayosi.

    1989-01-01

    Indoor radon concentrations of 792 houses in Osaka, Nara, Wakayama and Hyogo were measured by the passive dosemeter which was developed in Karlsruhe Nuclear Research Center in West Germany. Each house was measured at two places for successive two periods of six months to obtain annual average exposure due to radon daughters. The arithmetic mean concentration of all houses was 45.2 Bq/m 3 with a standard deviation of 27.2; the geometric mean, 40.7 Bq/m 3 and the median, 39 Bq/m 3 . The distribution of the radon levels was approximately log-normal with 80% of houses having radon concentrations less than 60 Bq/m 3 . The seasonal variation of the mean radon concentration was evident between the former period including winter value of 45 Bq/m 3 and the latter including summer value of 32 Bq/m 3 . The indoor radon concentrations of wooden houses were found to have the widest distribution with the highest value of 371 Bq/m 3 . The highest value obtained in the ferro-concrete house was 118 Bq/m 3 . Twelve houses having indoor radon concentrations higher than 120 Bq/m 3 were all Japanese traditional wooden houses with walls made of soil. (author)

  4. Full-field dye concentration measurement within saturated/unsaturated thin slabs of porous media

    International Nuclear Information System (INIS)

    Norton, D.L.; Glass, R.J.

    1993-01-01

    This paper presents a full-field dye concentration measurement technique that extends our experimental capabilities to the measurement of transient dye concentration fields within steady state flow fields under unsaturated or saturated conditions. Simple light absorption theory provides a basis for translating images into high resolution dye concentration fields. A series of dye pulse experiments that demonstrate the combined use of the full-field saturation and dye concentration techniques was conducted at four different degrees of saturation. Each of these experimental sequences was evaluated with respect to mass balance, the results being within 5% of the known dye mass input. An image windowing technique allowed us to see increased dispersion due to decreasing moisture content, tailing of concentration at the rear of the dye pulse and slight velocity changes of the dispersive front due to changes in moisture content. The exceptional resolution of dye concentration in space and time provided by this laboratory technique allows systematic experimentation for examining basic processes affecting solute transport within saturated/unsaturated porous media. Future challenges for this work will be to use these techniques to analyze more complex systems involving heterogeneities, scaling laws, and detailed investigations of the relationship between transverse and longitudinal dispersion in unsaturated media

  5. Saliva oxytocin measures do not reflect peripheral plasma concentrations after intranasal oxytocin administration in men.

    Science.gov (United States)

    Quintana, Daniel S; Westlye, Lars T; Smerud, Knut T; Mahmoud, Ramy A; Andreassen, Ole A; Djupesland, Per G

    2018-05-16

    Oxytocin plays an important role in social behavior. Thus, there has been significant research interest for the role of the oxytocin system in several psychiatric disorders, and the potential of intranasal oxytocin administration to treat social dysfunction. Measurement of oxytocin concentrations in saliva are sometimes used to approximate peripheral levels of oxytocin; however, the validity of this approach is unclear. In this study, saliva and plasma oxytocin was assessed after two doses of Exhalation Delivery System delivered intranasal oxytocin (8 IU and 24 IU), intravenous oxytocin (1 IU) and placebo in a double-dummy, within-subjects design with men. We found that intranasal oxytocin (8 IU and 24 IU) administration increased saliva oxytocin concentrations in comparison to saliva oxytocin concentration levels after intravenous and placebo administration. Additionally, we found that saliva oxytocin concentrations were not significantly associated with plasma oxytocin concentrations after either intranasal or intravenous oxytocin administration. Altogether, we suggest that saliva oxytocin concentrations do not accurately index peripheral oxytocin after intranasal or intravenous oxytocin administration, at least in men. The data indicates that elevated oxytocin saliva levels after nasal delivery primarily reflect exogenous administered oxytocin that is cleared from the nasal cavity to the oropharynx, and is therefore a weak surrogate for peripheral blood measurements. Copyright © 2018 Elsevier Inc. All rights reserved.

  6. Comparison of VIDAS and Radioimmunoassay Methods for Measurement of Cortisol Concentration in Bovine Serum

    Directory of Open Access Journals (Sweden)

    Daniela Proverbio

    2013-01-01

    Full Text Available Radioimmunoassay (RIA is the “gold standard” method for evaluation of serum cortisol concentration. The VIDAS cortisol test is an enzyme-linked fluorescent assay designed for the MiniVidas system. The aim of this study was to compare the VIDAS method with RIA for measurement of bovine serum cortisol concentration. Cortisol concentrations were evaluated in 40 cows using both VIDAS and RIA methods, the latter as the reference method. A paired Student’s -test, Pearson’s correlation analysis, Bland-Altman plot, and Deming regression analysis were used to compare the two methods. There was no statistically significant difference between mean serum cortisol concentrations measured by VIDAS or RIA methods (. Both methods were able to detect significant differences in mean low and high cortisol concentrations ( RIA and VIDAS. The correlation coefficient was low, but a Bland-Altman plot and Deming regression analysis show neither constant nor proportional error. The VIDAS method produced slightly higher values than RIA, but the difference was small and in no case did the mean value move the normal range. Results suggest that VIDAS method is suitable for the determination of bovine serum cortisol concentration in studies of large numbers of animals.

  7. Serum cystatin C concentration measured routinely is a prognostic marker for renal disease in dogs.

    Science.gov (United States)

    Iwasa, Naoki; Takashima, Satoshi; Iwasa, Tatsuo; Iwasa, Kazuko; Suzuki, Tomomi; Kobatake, Yui; Kitagawa, Hitoshi; Nishii, Naohito

    2018-06-14

    This study examined the predictive value of serum cystatin C (Cys-C) concentration, measured during routine periodic health examinations, in the renal prognosis of dogs. A cohort of 140 dogs weighing C concentrations were measured during periodic health examinations from December 2013 to March 2016 were prospectively studied, with renal disease-related death the predicted end point. Of the 140 dogs, nine died from renal diseases during the follow-up period (539 ± 249 days). Serum Cys-C concentrations were higher in the dogs that subsequently died of renal disease than in the censored group (0.8 ± 0.25 vs. 0.3 ± 0.1 mg/dl, respectively; P C concentrations (>0.55 mg/dl) had a shorter (P C concentrations (≤0.55 mg/dl). In conclusion, high serum Cys-C concentrations in periodic health examinations in dogs <15 kg predicted poorer prognosis for renal function. Copyright © 2018. Published by Elsevier Ltd.

  8. In Situ Measurements of Aerosol Mass Concentration and Spectral Absorption at Three Location in and Around Mexico City

    Science.gov (United States)

    Chaudhry, Z.; Martins, V.; Li, Z.

    2006-12-01

    As a result of population growth and increasing industrialization, air pollution in heavily populated urban areas is one of the central environmental problems of the century. As a part of the MILAGRO (Megacity Initiative: Local and Global Research Observations) study, Nuclepore filters were collected in two size ranges (PM10 and PM2.5) at 12 hour intervals at three location in Mexico during March, 2006. Sampling stations were located at the Instituto Mexicano del Petroleo (T0), at the Rancho La Bisnago in the State of Hidalgo (T2) and along the Gulf Coast in Tampico (Tam). Each filter was analyzed for mass concentration, aerosol scattering and absorption efficiencies. Mass concentrations at T0 ranged from 47 to 179 μg/m3 for PM10 with an average concentration of 96 μg/m3, and from 20 to 93 μg/m3 for PM2.5 with an average concentration of 41 μg/m3. Mass concentrations at T2 ranged from 12 to 154 μg/m3 for PM10 with an average concentration of 51 μg/m3, and from 7 to 50 μg/m3 for PM2.5 with an average concentration of 25 μg/m3. Mass concentrations at Tam ranged from 34 to 80 μg/m3 for PM10 with an average concentration of 52 μg/m3, and from 8 to 23 μg/m3 for PM2.5 with an average concentration of 13 μg/m3. While some of the extreme values are likely linked to local emissions, regional air pollution episodes also played important roles. Each of the sampling stations experienced a unique atmospheric condition. The site at T0 was influenced by urban air pollution and dust storms, the site at T2 was significantly less affected by air pollution but more affected by regional dust storms and local dust devils while Tam was influenced by air pollution, dust storms and the natural marine environment. The spectral mass absorption efficiency was measured from 350 to 2500 nm and shows large differences between the absorption properties of soil dust, black carbon, and organic aerosols. The strong spectral differences observed can be related to differences in

  9. Measurement of Rn-222 concentration in underground water in Osaka stratum group in Sennan area

    International Nuclear Information System (INIS)

    Fukui, Masami; Katsurayama, Kosuke

    1977-01-01

    The Rn-222 concentration in underground water is reported as follows, which is the result obtained when the ground inspection was carried out in the Research Reactor Institute of Kyoto University located at Kumatori area in Osaka stratum group. Underground water, at different depth, well water and rain water were taken, and the contained Rn-222 was extracted with toluene to measure by liquid scintillation technique. Rn-222 concentration in rain water was 3.5 - 8.0 pCi/l, while the concentration in well water was 130 - 250 pCi/l, and that in underground water was 240 - 313 pCi/l. The seasonal change, geographical difference and variation according to depth of Rn-222 concentration were examined. Rn-222 behavior in soil should be investigated more in detail in reference to Rn-222 dispersion, transport and equilibrium problems in soil-water system in the future. (Kobatake, H.)

  10. GUM approach to uncertainty estimations for online 220Rn concentration measurements using Lucas scintillation cell

    International Nuclear Information System (INIS)

    Sathyabama, N.

    2014-01-01

    It is now widely recognized that, when all of the known or suspected components of errors have been evaluated and corrected, there still remains an uncertainty, that is, a doubt about how well the result of the measurement represents the value of the quantity being measured. Evaluation of measurement data - Guide to the expression of Uncertainty in Measurement (GUM) is a guidance document, the purpose of which is to promote full information on how uncertainty statements are arrived at and to provide a basis for the international comparison of measurement results. In this paper, uncertainty estimations following GUM guidelines have been made for the measured values of online thoron concentrations using Lucas scintillation cell to prove that the correction for disequilibrium between 220 Rn and 216 Po is significant in online 220 Rn measurements

  11. Data on final calcium concentration in native gel reagents determined accurately through inductively coupled plasma measurements

    Directory of Open Access Journals (Sweden)

    Jeffrey Viviano

    2016-03-01

    Full Text Available In this article we present data on the concentration of calcium as determined by Inductively Coupled Plasma (ICP measurements. Calcium was estimated in the reagents used for native gel electrophoresis of Neuronal Calcium Sensor (NCS proteins. NCS proteins exhibit calcium-dependent mobility shift in native gels. The sensitivity of this shift to calcium necessitated a precise determination of calcium concentrations in all reagents used. We determined the calcium concentrations in different components used along with the samples in the native gel experiments. These were: 20 mM Tris pH 7.5, loading dye and running buffer, with distilled water as reference. Calcium determinations were through ICP measurements. It was found that the running buffer contained calcium (244 nM over the blank. Keywords: Neuronal calcium sensor proteins, Electrophoresis, Mobility shift, Calcium, Magnesium

  12. Heat transfer analysis in a calorimeter for concentrated solar radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Estrada, C.A.; Jaramillo, O.A.; Arancibia-Bulnes, C.A. [Universidad Nacional Autonoma de Mexico, Centro de Investigacion en Energia, Privada Xochicalco S/N, Col. Centro. Temixco, Morelos 62580 (Mexico); Acosta, R. [Universidad de Quintana Roo, Boulevard Bahia s/n Esq. I. Comonfort, Chetumal Quintana Roo 77019 (Mexico)

    2007-10-15

    A calorimeter was built for measuring the concentrated solar power produced by a point focus solar concentrator that was developed at CIE - UNAM. In order to obtain a thermal characterization of the calorimeter a theoretical and experimental heat transfer study is carried out. This study addresses the heat transfer in the circular flat plate of the calorimeter, which acts as receiver for the concentrating system. Temperatures are measured at different points of this plate and fit with a theoretical model that considers heat conduction with convective and radiative boundary conditions. In particular, it is possible to calculate the temperature distribution on the irradiated surface. This allows to examine the validity of the assumptions of cold water calorimetry, which was the technique applied to this system in previous works. (author)

  13. Measurement of gross alpha and gross beta activity concentrations in human tooth

    International Nuclear Information System (INIS)

    Soeguet, Omer; Aydin, Mehmet Fatih; Kuecuekoender, Erdal; Zorer, Ozlem Selcuk; Dogru, Mahmut

    2010-01-01

    The gross alpha and gross beta activity concentrations were measured in human tooth taken from 3 to 6 age-groups to 40 and over ones. Accumulated teeth samples are investigated in two groups as under and above 18 years. The gross alpha and beta radioactivity of human tooth samples was measured by using a gas-flow proportional counter (PIC-MPC 9604-α/β counter). In tooth samples, for female age-groups, the obtained results show that the mean gross alpha and gross beta activity concentrations varied between 0.534-0.203 and 0.010-0.453 Bq g -1 and the same concentrations for male age-groups varied between 0.009-1.168 and 0.071-0.204 Bq g -1 , respectively.

  14. Measurement of radon exhalation rate and soil gas radon concentration in areas of southern Punjab (Pakistan)

    International Nuclear Information System (INIS)

    Mujahid, S. A.; Hussain, S.; Ramzan, M.

    2010-01-01

    Plastic track detectors were used to measure the radon concentration and exhalation rate from the soil samples. The samples were collected from areas of southern Punjab (Pakistan). In a laboratory experiment, passive alpha dosemeters were installed inside cylindrical bottles containing the soil samples. The radon concentrations and the radon exhalation rate were found in the ranges of 34±7 to 260±42 Bq m -3 and 38±8 to 288±46 mBq m -2 h -1 , respectively. The on-site measurements of radon in the soil gas were also carried out in these areas using a scintillation alpha counter. The concentration of radon in the soil gas was found in the range of 423±82-3565±438 Bq m -3 . (authors)

  15. Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography

    Science.gov (United States)

    Chen, Tseng-Lin; Lo, Yu-Lung; Liao, Chia-Chi; Phan, Quoc-Hung

    2018-04-01

    A method is proposed for determining the glucose concentration on the human fingertip by extracting two optical parameters, namely the optical rotation angle and the depolarization index, using a Mueller optical coherence tomography technique and a genetic algorithm. The feasibility of the proposed method is demonstrated by measuring the optical rotation angle and depolarization index of aqueous glucose solutions with low and high scattering, respectively. It is shown that for both solutions, the optical rotation angle and depolarization index vary approximately linearly with the glucose concentration. As a result, the ability of the proposed method to obtain the glucose concentration by means of just two optical parameters is confirmed. The practical applicability of the proposed technique is demonstrated by measuring the optical rotation angle and depolarization index on the human fingertip of healthy volunteers under various glucose conditions.

  16. Measurement of the terrestrial and anthropogenic radionuclide concentrations in Bafra Kizilirmak delta (bird sanctuary) in Turkey

    International Nuclear Information System (INIS)

    Mutuk, H.; Guemues, H.; Turhan, S.

    2014-01-01

    In this study, the activity concentrations of terrestrial and anthropogenic radionuclides in the soil samples collected from Bafra Kizilirmak Delta were measured by using gamma spectrometry with an NaI(Tl) detector. The average values of activity concentrations of 238 U, 232 Th and 40 K were found to be 37.2±2.8, 33.7±3.1 and 413.0±59.8 Bq kg -1 , respectively. 137 Cs was also measured in some samples. It has a mean value of 13.8±1.0 Bq kg -1 . From the activity concentrations, the absorbed gamma dose rates in outdoor and the corresponding annual effective dose rates and external hazard index (Hex) were estimated. (authors)

  17. Measurement of the terrestrial and anthropogenic radionuclide concentrations in Bafra Kizilirmak delta (bird sanctuary) in Turkey.

    Science.gov (United States)

    Mutuk, Halil; Gümüs, Hasan; Turhan, Seref

    2014-01-01

    In this study, the activity concentrations of terrestrial and anthropogenic radionuclides in the soil samples collected from Bafra Kızılırmak Delta were measured by using gamma spectrometry with an NaI(Tl) detector. The average values of activity concentrations of (238)U, (232)Th and (40)K were found to be 37.2±2.8, 33.7±3.1 and 413.0±59.8 Bq kg(-1), respectively. (137)Cs was also measured in some samples. It has a mean value of 13.8±1.0 Bq kg(-1). From the activity concentrations, the absorbed gamma dose rates in outdoor and the corresponding annual effective dose rates and external hazard index (Hex) were estimated.

  18. Passive Sampler for Measurements of Atmospheric Nitric Acid Vapor (HNO3 Concentrations

    Directory of Open Access Journals (Sweden)

    Andrzej Bytnerowicz

    2001-01-01

    Full Text Available Nitric acid (HNO3 vapor is an important nitrogenous air pollutant responsible for increasing saturation of forests with nitrogen and direct injury to plants. The USDA Forest Service and University of California researchers have developed a simple and inexpensive passive sampler for monitoring air concentrations of HNO3. Nitric acid is selectively absorbed on 47-mm Nylasorb nylon filters with no interference from particulate NO3-. Concentrations determined with the passive samplers closely corresponded with those measured with the co-located honeycomb annular denuder systems. The PVC protective caps of standardized dimensions protect nylon filters from rain and wind and allow for reliable measurements of ambient HNO3 concentrations. The described samplers have been successfully used in Sequoia National Park, the San Bernardino Mountains, and on Mammoth Mountain in California.

  19. Measurement of concentration and size distribution of radon decay products in homes using air cleaners

    International Nuclear Information System (INIS)

    Montassier, N.; Hopke, P.K.; Shi, Y.; McCallum, B.

    1992-01-01

    By removing particles, air cleaners can also eliminate radon decay products. However, by removing the particles, the open-quotes unattachedclose quotes fraction of the radon progeny is increased leading to a higher dose per unit exposure. Thus, both the concentration and size distributions of the radon decay products are needed to evaluate air cleaners. Three types of room air cleaners, NO-RAD Radon Removal System, Electronic Air Cleaner and PUREFLOW Air Treatment System were tested in a single family home in Arnprior, Ontario (Canada). Semi-continuous measurements of radon gas concentration and radon decay product activity weighted size distribution were performed in the kitchen/dining room under real living conditions. The effects of air cleaners on both the concentration and size distribution of the radon decay products were measured, and their impact on the dose of radiation given to the lung tissue were examined

  20. Measurement of chloride-ion concentration with long-period grating technology

    Science.gov (United States)

    Tang, Jaw-Luen; Wang, Jian-Neng

    2007-06-01

    A simple and low-cost long-period fiber grating (LPG) sensor suited for chloride-ion concentration measurement is presented. The LPG sensor is found to be sensitive to the refractive index of the medium around the cladding surface of the sensing grating, thus offering the prospect of development of practical sensors such as an ambient index sensor or a chemical concentration indicator with high stability and reliability. We measured chloride ions in a typical concrete sample immersed in salt water solutions with different weight concentrations ranging from 0% to 25%. Results show that the LPG sensor exhibited a linear decrease in the transmission loss and resonance wavelength shift when the concentration increased. The measurement accuracy for the concentration of salt in water solution is estimated to be 0.6% and the limit of detection for chloride ions is about 0.04%. To further enhance its sensitivity for chloride concentrations, we coated a monolayer of colloidal gold nanoparticles as the active material on the grating surface of the LPG sensor. The operating principle of sensing is based on the sensitivity of localized surface plasmon resonance of self-assembled gold colloids on the grating section of the LPG. With this method, a factor of two increase in the sensitivity of detecting chemical solution concentrations was obtained. The advantages of this type of fiber-optic sensor are that it is compact, relatively simple to construct and easy to use. Moreover, the sensor has the potential capability for on-site, in vivo and remote sensing, and it has potential use as a disposable sensor.

  1. High frequency measurement of nitrate concentration in the Lower Mississippi River, USA

    Science.gov (United States)

    Duan, Shuiwang; Powell, Rodney T.; Bianchi, Thomas S.

    2014-11-01

    Nutrient concentrations in the Mississippi River have increased dramatically since the 1950s, and high frequency measurements on nitrate concentration are required for accurate load estimations and examinations on nitrate transport and transformation processes. This three year record of high temporal resolution (every 2-3 h) data clearly illustrates the importance of high frequency sampling in improving load estimates and resolving variations in nitrate concentration with river flow and tributary inputs. Our results showed large short-term (days to weeks) variations in nitrate concentration but with no diurnal patterns. A repeatable and pronounced seasonal pattern of nitrate concentration was observed, and showed gradual increases from the lowest values in September (during base-flow), to the highest in June - which was followed by a rapid decrease. This seasonal pattern was only moderately linked with water discharge, and more controlled by nitrogen transformation/export from watershed as well as mixing patterns of the two primary tributaries (the upper Mississippi and the Ohio Rivers), which have distinctly different nitrate concentrations and flow patterns. Based on continuous in situ flow measurements, we estimated 554-886 × 106 kg of nitrate-N was exported from the Mississippi River system during years 2004-2006, which was <9% and <16% lower than U.S. Geological Survey's (USGS) estimates using their LOADEST or composite methods, respectively. USGS methods generally overestimated nitrate loads during rising stages and underestimated the loads during falling stages. While changes in nitrate concentrations in large rivers are generally not as responsive to alterations in diurnal inputs and/or watershed hydrology as small rivers, high-frequency water quality sampling would help in monitoring short-term (days to weeks) variations in nutrient concentration patterns and thus improve the accuracy of nutrient flux estimates.

  2. Is lowering reducing sugars concentration in French fries an effective measure to reduce acrylamide concentration in food service establishments?

    NARCIS (Netherlands)

    Sanny, M.A.I.; Jinap, S.; Bakker, E.J.; Boekel, van M.A.J.S.; Luning, P.A.

    2012-01-01

    The objective of this study was to obtain insight into the actual effectiveness of lowering reducing sugars concentration in par-fried potato strips on the concentration and variation of acrylamide in French fries prepared in real-life situations in food service establishments. Acrylamide, frying

  3. Analysis of local-scale background concentrations of methane and other gas-phase species in the Marcellus Shale

    Directory of Open Access Journals (Sweden)

    J. Douglas Goetz

    2017-02-01

    Full Text Available The Marcellus Shale is a rapidly developing unconventional natural gas resource found in part of the Appalachian region. Air quality and climate concerns have been raised regarding development of unconventional natural gas resources. Two ground-based mobile measurement campaigns were conducted to assess the impact of Marcellus Shale natural gas development on local scale atmospheric background concentrations of air pollution and climate relevant pollutants in Pennsylvania. The first campaign took place in Northeastern and Southwestern PA in the summer of 2012. Compounds monitored included methane (CH4, ethane, carbon monoxide (CO, nitrogen dioxide, and Proton Transfer Reaction Mass Spectrometer (PTR-MS measured volatile organic compounds (VOC including oxygenated and aromatic VOC. The second campaign took place in Northeastern PA in the summer of 2015. The mobile monitoring data were analyzed using interval percentile smoothing to remove bias from local unmixed emissions to isolate local-scale background concentrations. Comparisons were made to other ambient monitoring in the Marcellus region including a NOAA SENEX flight in 2013. Local background CH4 mole fractions were 140 ppbv greater in Southwestern PA compared to Northeastern PA in 2012 and background CH4 increased 100 ppbv from 2012 to 2015. CH4 local background mole fractions were not found to have a detectable relationship between well density or production rates in either region. In Northeastern PA, CO was observed to decrease 75 ppbv over the three year period. Toluene to benzene ratios in both study regions were found to be most similar to aged rural air masses indicating that the emission of aromatic VOC from Marcellus Shale activity may not be significantly impacting local background concentrations. In addition to understanding local background concentrations the ground-based mobile measurements were useful for investigating the composition of natural gas emissions in the region.

  4. Radon as an environmental risk: concentration measurements in family buildings at Cordoba city

    International Nuclear Information System (INIS)

    Bonzi, A.; Murua, C.; Martin, H.R.

    1992-01-01

    Measurements of radon concentration at homes are usual activities in the last years at the countries with uranium in their soils. On the other hand, the man's radiological protection about radiation is related to the environmental actions for a healthy life, but not much known for a public. The great quantities of ore with uranium can be an important source of irradiation when they are used as building materials. The soils are important too for the emanations of radon in the interior of buildings and for these reasons, the radon concentration measurements in Cordoba familiar houses were implemented in the summer of 1991. The Alpha Track Technique and the results obtained indicate the need of other measurements and a winter measurement for investigation variations of radon concentration. The typical values measured were low, about 4.13 Bq/m 3 if they are compared with other Argentine values measured. This paper discusses the procedure, techniques and criteria used in the work held in Cordoba city, Argentina. (Author)

  5. Evaluation of methodological aspects of digestibility measurements in ponies fed different haylage to concentrate ratios

    NARCIS (Netherlands)

    Schaafstra, F J W C; van Doorn, D A; Schonewille, J T; van Riet, M M J; Hendriks, W H

    2017-01-01

    Methodological aspects of digestibility measurements were studied in four Welsh pony geldings consuming haylage-based diets with increasing proportions of a pelleted concentrate according to a 4×4 Latin square design experiment. Ponies were fed four experimental, iso-energetic (net energy (NE)

  6. Evaluation of methodological aspects of digestibility measurements in ponies fed different haylage to concentrate ratios

    NARCIS (Netherlands)

    Schaafstra, F.J.W.C.; Doorn, van D.A.; Schonewille, J.T.; Riet, van M.M.J.; Visser, P.; Blok, M.C.; Hendriks, W.H.

    2017-01-01

    Methodological aspects of digestibility measurements were studied in four Welsh pony geldings consuming haylage-based diets with increasing proportions of a pelleted concentrate according to a 4×4 Latin square design experiment. Ponies were fed four experimental, iso-energetic (net energy (NE)

  7. Thoron and radon progeny concentration measurements using direct progeny sensors in HLNRAs of Kerala

    International Nuclear Information System (INIS)

    Mishra, R.; Prajith, R.; Gole, A.C.; Kanse, S.D.; Chougaonkar, M.P.; Sapra, B.K.; Mayya, Y.S.; Jayalekshmi, P.; Nair, Raghu Ram K.

    2010-01-01

    Passive Progeny Dosimeters (PPDs) were deployed in 500 houses in 3 villages namely Allapad, Chavara and Neendakara villages of Karunagapally Taluk of Kollam district of Kerala. Each PPD unit is a combination of a DTPS and a DRPS placed side-by-side for time integrated thoron and radon progeny concentration estimation respectively. The PPDs were suspended vertically in the rooms, such that the nearest distance from any wall or surface was at least 30 cm. These are, as of now, being exposed for a period of 3 months, after which they will be retrieved and analysed by chemical etching and track counting. Simultaneously, external gamma radiation measurements have also been made using a survey meter; these showed a variation from 13 to 118 μR/h in indoors and 21 to 213 μR/h in the outdoor environments. Spot measurements of thoron progeny concentrations were also made in 7 selected houses using the conventional grab filter-paper sampling technique at a flow-rate of 21 min -1 for 30 minutes, followed by alpha counting. The average thoron progeny concentration was found to be 2.0 ± 0.7 Bq m -3 . In the outdoor environment, filter-paper sampling was carried out for 2 hours at 21 min -1 and the thoron progeny concentration was measured as 2.96 Bq m -3 . To corroborate these measurements, a flow mode integrated sampler which uses the DTPS and DRPS elements was used

  8. Optimizing measurement sensitivity to facilitate monitoring environmental levels of Rn-daughter concentrations

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Groer, P.G.; Witek, R.T.

    1977-01-01

    In the measurement of environmental levels of radioactivity, the primary problem is the accumulation of a statistically meaningful number of counts within a reasonable period of time. In the case of measurements of airborne 222 Rn-daughter concentrations, the problem is further complicated by the particularly short half-life, 3.05 minutes, of RaA (Po 218 ). Since the Rn-daughters, (RaA, RaB [Pb 214 ] and RaC [Bi 214 ]) are of interest, the equations interrelating these Rn-daughter concentrations were derived from the laws of radioactive-series decay. These equations, although straightforward, are cumbersome to solve. To facilitate the efficient use of these equations, a computer program has been written which permits the calculation of Rn-daughter concentrations or expected counts for a given set of measurement parameters (flow rate and detector efficiencies). A subroutine then calculates the optimum pumping and counting times required to provide the number of counts necessary for acceptable statistics at environmental levels of 222 Rn-daughter concentrations. This subroutine contains a set of parameters, flow rate and efficiencies, that are fixed using realistic restrictions. The use of these optimized pumping and counting times results in maximum measurement sensitivity under realistic constraints

  9. Critical micelle concentration values for different surfactants measured with solid-phase microextraction fibers

    NARCIS (Netherlands)

    Haftka, Joris J H; Scherpenisse, Peter; Oetter, G??nter; Hodges, Geoff; Eadsforth, Charles V.; Kotthoff, Matthias; Hermens, Joop L M

    The amphiphilic nature of surfactants drives the formation of micelles at the critical micelle concentration (CMC). Solid-phase microextraction (SPME) fibres were used in the present study to measure CMC values of twelve nonionic, anionic, cationic and zwitterionic surfactants. The SPME derived CMC

  10. Using Conductivity Measurements to Determine the Identities and Concentrations of Unknown Acids: An Inquiry Laboratory Experiment

    Science.gov (United States)

    Smith, K. Christopher; Garza, Ariana

    2015-01-01

    This paper describes a student designed experiment using titrations involving conductivity measurements to identify unknown acids as being either HCl or H[subscript 2]SO[subscript 4], and to determine the concentrations of the acids, thereby improving the utility of standard acid-base titrations. Using an inquiry context, students gain experience…

  11. Optical sensor technology for simultaneous measurement of particle speed and concentration of micro sized particles

    DEFF Research Database (Denmark)

    Clausen, Casper; Han, Anpan; Kristensen, Martin

    2013-01-01

    Experimental characterization of a sensor technology that can measure particle speed and concentration simultaneously in liquids and gases is presented here. The basic sensor principle is based on an optical element that shapes a light beam into well-defined fringes. The technology can be described...

  12. Measurement of uranium concentration by molecular absorption spectrophotometry by means optical fibers

    International Nuclear Information System (INIS)

    Gauna, Alberto C.; Pascale, Ariel A.

    1996-01-01

    An on-line method for measuring the concentration of uranium in uranyl nitrate-nitric acid aqueous solutions is described. The method is based on molecular absorption spectrophotometry with transmission of light by means of optical fibers. It is ideally suited for control and processes development applications. (author)

  13. Planar measurements of velocity and concentration of turbulent mixing in a T-junction

    DEFF Research Database (Denmark)

    Ingvorsen, Kristian Mark; Meyer, Knud Erik; Nielsen, N. F.

    Turbulent mixing of two isothermal air streams in a T-junction of square ducts are investigated. Three dimensional velocity fields and turbulent kinetic energy are measured with stereoscopic Particle Image Velocimetry (PIV). The concentration field is obtained with a planar Mie scattering technique...

  14. Testing of a uranium downhole logging system to measure in-situ plutonium concentrations in sediments

    International Nuclear Information System (INIS)

    Kasper, R.B.; Kay, M.A.; Bruns, L.E.; Stokes, J.A.; Steinman, D.K.; Adams, J.

    1980-11-01

    A prototype urainium borehole logging system, developed for uranium exploration, was modified for Pu assay and testing at the site. It uses the delayed fission neutron (DFN) method. It was tested in a retired Pu facility, the 216-Z-1A Crib. General agreement between laboratory determined Pu concentrations in sediment samples and neutron flux measurements was found for the relative distribution with depth

  15. To Error Problem Concerning Measuring Concentration of Carbon Oxide by Thermo-Chemical Sen

    Directory of Open Access Journals (Sweden)

    V. I. Nazarov

    2007-01-01

    Full Text Available The paper gives additional errors in respect of measuring concentration of carbon oxide by thermo-chemical sensors. A number of analytical expressions for calculation of error data and corrections for environmental factor deviations from admissible ones have been obtained in the paper

  16. Water leak detection in sodium heated steam generators through measurement of hydrogen concentration in sodium

    International Nuclear Information System (INIS)

    Cambillard, E.; Lacroix, A.; Martin, P.; Viala, J.

    1980-07-01

    This report includes a description of apparatus for measuring hydrogen concentration in the secondary sodium system of the PHENIX reactor. The calibration method and results obtained since the commissioning of the reactor are also described. Mention is made of improvements to be built into SUPER PHENIX [fr

  17. Concentration Measurements of Suspended Load using ADV with Influence of the Particle Size

    Science.gov (United States)

    Schwarzwälder, Kordula

    2017-04-01

    ADV backscatter data can be used under certain conditions to gain information about the concentrations of suspended loads. This was shown in many studies before (Fugate and Friedrichs 2002; Chanson et al 2008; Ha et al. 2009). This paper reports on a pre-study to investigate the influence of particle size on concentration measurements for suspended sediment load with ADV. The study was conducted in a flume in the Oskar-von-Miller-Institute using fresh water from a river including the natural suspended load. The ADV used in the experiments was a Vectrino Profiler (Nortek). In addition water samples were taken for TSS and TOC. For the measurements a surge was generated in the flume to ensure that also particles of larger size will be present in the water phase. The measurements and samples were taken during the whole surge event. Therefore we were able to find a good correlation between the backscatter data of the ADV and the TSS as well as TOC results. For the decreasing part of the flow event the concentration of TOC in the suspended load of the water phase is decreasing much slower than the TSS and results in a damped decrease of the backscatter values. This means that the results for concentration measurements might be slightly influenced by the size of the particles. Further evaluations of measurements conducted with a LISST SL (Sequoia) will be investigated to show the trend of the particle sizes during this process and fortify this result. David C. Fugate, Carl T. Friedrichs, Determining concentration and fall velocity of estuarine particle populations using ADV, OBS and LISST, Continental Shelf Research, Volume 22, Issues 11-13, 2002 H.K. Ha, W.-Y. Hsu, J.P.-Y. Maa, Y.Y. Shao, C.W. Holland, Using ADV backscatter strength for measuring suspended cohesive sediment concentration, Continental Shelf Research, Volume 29, Issue 10, 2009 Hubert Chanson, Maiko Takeuchi, Mark Trevethan, Using turbidity and acoustic backscatter intensity as surrogate measures of

  18. A measure of the denseness of a phylogenetic network. [by sequenced proteins from extant species

    Science.gov (United States)

    Holmquist, R.

    1978-01-01

    An objective measure of phylogenetic denseness is developed to examine various phylogenetic criteria: alpha- and beta-hemoglobin, myoglobin, cytochrome c, and the parvalbumin family. Attention is given to the number of nucleotide replacements separating homologous sequences, and to the topology of the network (in other words, to the qualitative nature of the network as defined by how closely the studied species are related). Applications include quantitative comparisons of species origin, relation, and rates of evolution.

  19. Absolute choline concentration measured by quantitative proton MR spectroscopy correlates with cell density in meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Yue, Qiang [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan)]|[West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China); Shibata, Yasushi; Kawamura, Hiraku; Matsumura, Akira [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan); Isobe, Tomonori [Kitasato University, Department of Medical Technology, School of Allied Health Sciences, Minato, Tokyo (Japan); Anno, Izumi [University of Tsukuba, Department of Radiology, Institute of Clinical Medicine, Tsukuba, Ibaraki (Japan); Gong, Qi-Yong [West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China)]|[University of Liverpool, Division of Medical Imaging, Faculty of Medicine, Liverpool (United Kingdom)

    2009-01-15

    This study was aimed to investigate the relationship between quantitative proton magnetic resonance spectroscopy (1H-MRS) and pathological changes in meningioma. Twenty-two meningioma cases underwent single voxel 1H-MRS (point-resolved spectroscopy sequence, repetition time/echo time = 2,000 ms/68, 136, 272 ms). Absolute choline (Cho) concentration was calculated using tissue water as the internal reference and corrected according to intra-voxel cystic/necrotic parts. Pathological specimens were stained with MIB-1 antibody to measure cell density and proliferation index. Correlation analysis was performed between absolute Cho concentration and cell density and MIB-1 labeled proliferation index. Average Cho concentration of all meningiomas before correction was 2.95 {+-} 0.86 mmol/kg wet weight. It was increased to 3.23 {+-} 1.15 mmol/kg wet weight after correction. Average cell density of all meningiomas was 333 {+-} 119 cells/HPF, and average proliferation index was 2.93 {+-} 5.72%. A linear, positive correlation between cell density and Cho concentration was observed (r = 0.650, P = 0.001). After correction of Cho concentration, the correlation became more significant (r = 0.737, P < 0.001). However, no significant correlation between Cho concentration and proliferation index was found. There seemed to be a positive correlation trend after correction of Cho concentration but did not reach significant level. Absolute Cho concentration, especially Cho concentration corrected according to intra-voxel cystic/necrotic parts, reflects cell density of meningioma. (orig.)

  20. Historical occupational trichloroethylene air concentrations based on inspection measurements from Shanghai, China.

    Science.gov (United States)

    Friesen, Melissa C; Locke, Sarah J; Chen, Yu-Cheng; Coble, Joseph B; Stewart, Patricia A; Ji, Bu-Tian; Bassig, Bryan; Lu, Wei; Xue, Shouzheng; Chow, Wong-Ho; Lan, Qing; Purdue, Mark P; Rothman, Nathaniel; Vermeulen, Roel

    2015-01-01

    Trichloroethylene (TCE) is a carcinogen that has been linked to kidney cancer and possibly other cancer sites including non-Hodgkin lymphoma. Its use in China has increased since the early 1990s with China's growing metal, electronic, and telecommunications industries. We examined historical occupational TCE air concentration patterns in a database of TCE inspection measurements collected in Shanghai, China to identify temporal trends and broad contrasts among occupations and industries. Using a database of 932 short-term, area TCE air inspection measurements collected in Shanghai worksites from 1968 through 2000 (median year 1986), we developed mixed-effects models to evaluate job-, industry-, and time-specific TCE air concentrations. Models of TCE air concentrations from Shanghai work sites predicted that exposures decreased 5-10% per year between 1968 and 2000. Measurements collected near launderers and dry cleaners had the highest predicted geometric means (GM for 1986 = 150-190 mg m(-3)). The majority (53%) of the measurements were collected in metal treatment jobs. In a model restricted to measurements in metal treatment jobs, predicted GMs for 1986 varied 35-fold across industries, from 11 mg m(-3) in 'other metal products/repair' industries to 390 mg m(-3) in 'ships/aircrafts' industries. TCE workplace air concentrations appeared to have dropped over time in Shanghai, China between 1968 and 2000. Understanding differences in TCE concentrations across time, occupations, and industries may assist future epidemiologic studies in China. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2014.

  1. A rapid approach for measuring silver nanoparticle concentration and dissolution in seawater by UV-Vis.

    Science.gov (United States)

    Sikder, Mithun; Lead, Jamie R; Chandler, G Thomas; Baalousha, Mohammed

    2018-03-15

    Detection and quantification of engineered nanoparticles (NPs) in environmental systems is challenging and requires sophisticated analytical equipment. Furthermore, dissolution is an important environmental transformation process for silver nanoparticles (AgNPs) which affects the size, speciation and concentration of AgNPs in natural water systems. Herein, we present a simple approach for the detection, quantification and measurement of dissolution of PVP-coated AgNPs (PVP-AgNPs) based on monitoring their optical properties (extinction spectra) using UV-vis spectroscopy. The dependence of PVP-AgNPs extinction coefficient (ɛ) and maximum absorbance wavelength (λ max ) on NP size was experimentally determined. The concentration, size, and extinction spectra of PVP-AgNPs were characterized during dissolution in 30ppt synthetic seawater. AgNPs concentration was determined as the difference between the total and dissolved Ag concentrations measured by inductively coupled plasma-mass spectroscopy (ICP-MS); extinction spectra of PVP-AgNPs were monitored by UV-vis; and size evolution was monitored by atomic force microscopy (AFM) over a period of 96h. Empirical equations for the dependence of maximum absorbance wavelength (λ max ) and extinction coefficient (ɛ) on NP size were derived. These empirical formulas were then used to calculate the size and concentration of PVP-AgNPs, and dissolved Ag concentration released from PVP-AgNPs in synthetic seawater at variable particle concentrations (i.e. 25-1500μgL -1 ) and in natural seawater at particle concentration of 100μgL -1 . These results suggest that UV-vis can be used as an easy and quick approach for detection and quantification (size and concentration) of sterically stabilized PVP-AgNPs from their extinction spectra. This approach can also be used to monitor the release of Ag from PVP-AgNPs and the concurrent NP size change. Finally, in seawater, AgNPs dissolve faster and to a higher extent with the decrease in NP

  2. Assessment of a colorimetric method for the measurement of low concentrations of peracetic acid and hydrogen peroxide in water.

    Science.gov (United States)

    Domínguez-Henao, Laura; Turolla, Andrea; Monticelli, Damiano; Antonelli, Manuela

    2018-06-01

    The recent growing interest in peracetic acid (PAA) as disinfectant for wastewater treatment demands reliable and readily-available methods for its measurement. In detail, the monitoring of PAA in wastewater treatment plants requires a simple, accurate, rapid and inexpensive measurement procedure. In the present work, a method for analyzing low concentrations of PAA, adapted from the US EPA colorimetric method for total chlorine, is assessed. This method employs N,N-diethyl-p-phenylelnediamine (DPD) in the presence of an excess of iodide in a phosphate buffer system. Pink colored species are produced proportionally to the concentration of PAA in the sample. Considering that PAA is available commercially as an equilibrium solution of PAA and hydrogen peroxide (H 2 O 2 ), a measurement method for H 2 O 2 is also investigated. This method, as the one for the determination of PAA, is also based on the oxidation of iodide to iodine, with the difference that ammonium molybdate Mo(VI) is added to catalyze the oxidation reaction between H 2 O 2 and iodide, quantifying the total peroxides (PAA+ H 2 O 2 ). The two methods are suitable for concentration ranges from about 0.1-1.65 mg L -1 and from about 0.3-3.3 mg L -1 , respectively for PAA and H 2 O 2 . Moreover, the work elucidates some relevant aspects related to the operational conditions, kinetics and the possible interference of H 2 O 2 on PAA measurement. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Determination of minimum inhibitory concentrations of itraconazole, terbinafine and ketoconazole against dermatophyte species by broth microdilution method.

    Science.gov (United States)

    Bhatia, V K; Sharma, P C

    2015-01-01

    Various antifungal agents both topical and systemic have been introduced into clinical practice for effectively treating dermatophytic conditions. Dermatophytosis is the infection of keratinised tissues caused by fungal species of genera Trichophyton, Epidermophyton and Microsporum, commonly known as dermatophytes affecting 20-25% of the world's population. The present study aims at determining the susceptibility patterns of dermatophyte species recovered from superficial mycoses of human patients in Himachal Pradesh to antifungal agents; itraconazole, terbinafine and ketoconazole. The study also aims at determining the minimum inhibitory concentrations (MICs) of these agents following the recommended protocol of Clinical and Laboratory Standards Institute (CLSI) (M38-A2). A total of 53 isolates of dermatophytes (T. mentagrophyte-34 in no., T. rubrum-18 and M. gypseum-1) recovered from the superficial mycoses were examined. Broth microdilution method M38-A2 approved protocol of CLSI (2008) for filamentous fungi was followed for determining the susceptibility of dermatophyte species. T. mentagrophyte isolates were found more susceptible to both itraconazole and ketoconazole as compared to terbinafine (MIC50: 0.125 µg/ml for itraconazole, 0.0625 µg/ml for ketoconazole and 0.5 µg/ml for terbinafine). Three isolates of T. mentagrophytes (VBS-5, VBSo-3 and VBSo-73) and one isolate of T. rubrum (VBPo-9) had higher MIC values of itraconazole (1 µg/ml). Similarly, the higher MIC values of ketoconazole were observed in case of only three isolates of T. mentagrophyte (VBSo-30 = 2 µg/ml; VBSo-44, VBM-2 = 1 µg/ml). The comparative analysis of the three antifungal drugs based on t-test revealed that 'itraconazole and terbinafine' and 'terbinafine and ketoconazole' were found independent based on the P terbinafine and ketoconazole'. The MIC values observed in the present study based on standard protocol M38-A2 of CLSI 2008 might serve as reference for further studies

  4. Determination of minimum inhibitory concentrations of itraconazole, terbinafine and ketoconazole against dermatophyte species by broth microdilution method

    Directory of Open Access Journals (Sweden)

    V K Bhatia

    2015-01-01

    Full Text Available Purpose: Various antifungal agents both topical and systemic have been introduced into clinical practice for effectively treating dermatophytic conditions. Dermatophytosis is the infection of keratinised tissues caused by fungal species of genera Trichophyton, Epidermophyton and Microsporum, commonly known as dermatophytes affecting 20–25% of the world's population. The present study aims at determining the susceptibility patterns of dermatophyte species recovered from superficial mycoses of human patients in Himachal Pradesh to antifungal agents; itraconazole, terbinafine and ketoconazole. The study also aims at determining the minimum inhibitory concentrations (MICs of these agents following the recommended protocol of Clinical and Laboratory Standards Institute (CLSI (M38-A2. Methodology: A total of 53 isolates of dermatophytes (T. mentagrophyte-34 in no., T. rubrum-18 and M. gypseum-1 recovered from the superficial mycoses were examined. Broth microdilution method M38-A2 approved protocol of CLSI (2008 for filamentous fungi was followed for determining the susceptibility of dermatophyte species. Results: T. mentagrophyte isolates were found more susceptible to both itraconazole and ketoconazole as compared to terbinafine (MIC50: 0.125 µg/ml for itraconazole, 0.0625 µg/ml for ketoconazole and 0.5 µg/ml for terbinafine. Three isolates of T. mentagrophytes (VBS-5, VBSo-3 and VBSo-73 and one isolate of T. rubrum (VBPo-9 had higher MIC values of itraconazole (1 µg/ml. Similarly, the higher MIC values of ketoconazole were observed in case of only three isolates of T. mentagrophyte (VBSo-30 = 2 µg/ml; VBSo-44, VBM-2 = 1 µg/ml. The comparative analysis of the three antifungal drugs based on t-test revealed that 'itraconazole and terbinafine' and 'terbinafine and ketoconazole' were found independent based on the P < 0.005 in case of T. mentagrophyte isolates. In case of T. rubrum, the similarity existed between MIC values of 'itraconazole and

  5. Numerical investigation of the effect of particle concentration on particle measurement by digital holography

    Science.gov (United States)

    Zhao, Huafeng; Zhou, Binwu; Wu, Xuecheng; Wu, Yingchun; Gao, Xiang; Gréhan, Gérard; Cen, Kefa

    2014-04-01

    Digital holography plays a key role in particle field measurement, and appears to be a strong contender as the next-generation technology for diagnostics of 3D particle field. However, various recording parameters, such as the recording distance, the particle size, the wavelength, the size of the CCD chip, the pixel size and the particle concentration, will affect the results of the reconstruction, and may even determine the success or failure of a measurement. This paper presents a numerical investigation on the effect of particle concentration, the volume depth to evaluate the capability of digital holographic microscopy. Standard particles holograms with all known recording parameters are numerically generated by using a common procedure based on Lorenz-Mie scattering theory. Reconstruction of those holograms are then performed by a wavelet-transform based method. Results show that the reconstruction efficiency decreases quickly until particle concentration reaches 50×104 (mm-3), and decreases linearly with the increase of particle concentration from 50 × 104 (mm-3) to 860 × 104 (mm-3) in the same volume. The first half of the line waves larger than the second half. It also indicates that the increase of concentration leads the rise in average diameter error and z position error of particles. Besides, the volume depth also plays a key role in reconstruction.

  6. Measurement of particulate concentrations produced during bulk material handling at the Tarragona harbor

    Energy Technology Data Exchange (ETDEWEB)

    Artinano, B.; Gomez-Moreno, F.J.; Pujadas, M.; Moreno, N.; Alastuey, A.; Querol, X.; Martin, F.; Guerra, A.; Luaces, J.A.; Basora, J. [CIEMAT, Madrid (Spain)

    2007-09-15

    Bulk material handling can be a significant source of particles in harbor areas. The atmospheric impact of a number of loading/unloading activities of diverse raw materials has been assessed from continuous measurements of ambient particle concentrations recorded close to the emission sources. Two experimental campaigns have been carried out in the Tarragona port to document the impact of specific handling operations and bulk materials. Dusty bulk materials such as silica-manganese powder, tapioca, coal, clinker and lucerne were dealt with during the experiments. The highest impacts on ambient particle concentrations were recorded during handling of clinker. For this material and silica-manganese powder, high concentrations were recorded in the fine grain size ({lt}2.5 {mu}m). The lowest impacts on particulate matter concentrations were recorded during handling of tapioca and lucerne, mainly in the coarse grain size (2-5-10 {mu} m). The effectiveness of several emission abatement measures, such as ground watering to diminish coal particle resuspension, was demonstrated to reduce ambient concentrations by up to two orders of magnitude. The importance of other good practices in specific handling operations, such as controlling the height of the shovel discharge, was also evidenced by these experiments. The results obtained can be further utilized as a useful experimental database for emission factor estimations.

  7. Fluorescence measurement of atomic oxygen concentration in a dielectric barrier discharge

    Science.gov (United States)

    Dvořák, P.; Mrkvičková, M.; Obrusník, A.; Kratzer, J.; Dědina, J.; Procházka, V.

    2017-06-01

    Concentration of atomic oxygen was measured in a volume dielectric barrier discharge (DBD) ignited in mixtures of Ar + O2(+ H2) at atmospheric pressure. Two-photon absorption laser induced fluorescence (TALIF) of atomic oxygen was used and this method was calibrated by TALIF of Xe in a mixture of argon and a trace of xenon. The calibration was performed at atmospheric pressure and it was shown that quenching by three-body collisions has negligible effect on the life time of excited Xe atoms. The concentration of atomic oxygen in the DBD was around 1021 m-3 and it was stable during the whole discharge period. The concentration did not depend much on the electric power delivered to the discharge provided that the power was sufficiently high so that the visible discharge filled the whole reactor volume. Both the addition of hydrogen or replacing of argon by helium led to a significant decrease of atomic oxygen concentration. The TALIF measurements of O concentration levels in the DBD plasma performed in this work are made use of e.g. in the field analytical chemistry. The results contribute to understanding the processes of analyte hydride preconcentration and subsequent atomization in the field of trace element analysis where DBD plasma atomizers are employed.

  8. Rapid measurement of plasma free fatty acid concentration and isotopic enrichment using LC/MS

    Science.gov (United States)

    Persson, Xuan-Mai T.; Błachnio-Zabielska, Agnieszka Urszula; Jensen, Michael D.

    2010-01-01

    Measurements of plasma free fatty acids (FFA) concentration and isotopic enrichment are commonly used to evaluate FFA metabolism. Until now, gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) was the best method to measure isotopic enrichment in the methyl derivatives of 13C-labeled fatty acids. Although IRMS is excellent for analyzing enrichment, it requires time-consuming derivatization steps and is not optimal for measuring FFA concentrations. We developed a new, rapid, and reliable method for simultaneous quantification of 13C-labeled fatty acids in plasma using high-performance liquid chromatography-mass spectrometry (HPLC/MS). This method involves a very quick Dole extraction procedure and direct injection of the samples on the HPLC system. After chromatographic separation, the samples are directed to the mass spectrometer for electrospray ionization (ESI) and analysis in the negative mode using single ion monitoring. By employing equipment with two columns connected parallel to a mass spectrometer, we can double the throughput to the mass spectrometer, reducing the analysis time per sample to 5 min. Palmitate flux measured using this approach agreed well with the GC/C/IRMS method. This HPLC/MS method provides accurate and precise measures of FFA concentration and enrichment. PMID:20526002

  9. Measurement of particle size distribution and mass concentration of nuclear fuel aerosols

    International Nuclear Information System (INIS)

    Pickering, S.

    1982-01-01

    The particle size distribution and particle mass concentration of a nuclear fuel aerosol is measured by admitting the aerosol into a vertically-extending container, positioning an alpha particle detector within the container so that its window is horizontal and directed vertically, stopping the admission of aerosol into the container, detecting the alpha-activity of the particles of the aerosol sedimenting onto the detector window (for example in a series of equal time intervals until a constant level is reached), and converting the alpha-activity measurements into particle size distribution and/or particle mass concentration measurements. The detector is attached to a pivotted arm and by raising a counterweight can be lowered from the container for cleaning. (author)

  10. Measurements of ammonia concentrations, fluxes and dry deposition velocities to a spruce forest 1991-1995

    DEFF Research Database (Denmark)

    Andersen, H.V.; Hovmand, M.F.; Hummelshøj, P.

    1999-01-01

    The dry deposition velocities and fluxes of ammonia have been estimated from measurements of the vertical gradient of ammonia and micrometeorology above a spruce forest in western Jutland, Denmark. Measurements have been made in seven periods, each lasting about one week and covering all seasons...... measuring period characterized by easterly winds with dry conditions and high ammonia concentrations, and the emissions might relate to evaporation from ammonia saturated surfaces or emission from mineralization in the forest soil. In general, relatively high net deposition velocities were observed during...... at conditions with easterly winds, the air have passed central Jutland with large emission areas. Some of the relatively low deposition velocities or emissions were observed during conditions with low ammonia concentration and westerly winds. These observations might relate to a compensation point of the forest...

  11. Applicability of Stokes method for measuring viscosity of mixtures with concentration gradient

    Directory of Open Access Journals (Sweden)

    César Medina

    2017-12-01

    Full Text Available After measuring density and viscosity of a mixture of glycerin and water contained in a vertical pipe, a variation of these properties according to depth is observed. These gradients are typical of non-equilibrium states related to the lower density of water and the fact that relatively long times are necessary to achieve homogeneity. In the same pipe, the falling velocity of five little spheres is measured as a function of depth, and then a numerical fit is performed which agrees very well with experimental data. Based on the generalization of these results, the applicability of Stokes method is discussed for measuring viscosity of mixtures with a concentration gradient.

  12. Measurements of Radon Concentration in Several Wards of the University Clinical Center of Kosovo...

    OpenAIRE

    , Y. Halimi; , S. Kadiri; , G. Hodolli; , B. Xhafa; , A. Jonuzaj

    2016-01-01

    Understanding that what’s the level of environment pollution from radioactive pollutant in some wards of UCCK (University Clinical Center of Kosovo) in Prishtina are made measurements of α radiation which is the product of 222Rn and have been read doses of TLD to some staff workers in three wards of UCCK. All this is done to see the risk level of possible pollution. Concentration of radon 222Rn is measured with device CRM-510 portable instruments. During the measurements the apparatus has rec...

  13. Plasma assisted measurements of alkali metal concentrations in pressurized combustion processes

    International Nuclear Information System (INIS)

    Hernberg, R.; Haeyrinen, V.

    1995-01-01

    The plasma assisted method for continuous measurement of alkali metal concentrations in product gas flows of pressurized energy processes will be tested and applied at the 1.6 MW PFBC/G facility at Delft University of Technology in the Netherlands. Measurements will be performed during 1995 and 1996 at different stages of the research programme. The results are expected to give information about the influence of different process conditions on the generation of alkali metal vapours, the comparison of different methods for alkali measurement and the specific performance of our system. The project belongs to the Joule II extension program under contract JOU2-CT93-0431. (author)

  14. Measurements of radon concentrations in a sample representative of housing in Franche-Comte

    International Nuclear Information System (INIS)

    Aury, K.; Clinard, F.; Tillier, C.; Catelinois, O.; Pirard, P.; Aury, K.; Nourry, L.; Hochart, A.

    2008-01-01

    Three departments on four ones in Franche-Comte are classified at risk for radon: measurements are so compulsory in establishments receiving public. For the residential sector, no obligation of measurement are compulsory when french people spend 70% of their time in it. The data concerning homes are fragmentary and deserve to be completed. This campaign of measurements has confirmed the existence of radon in relatively high concentrations in Franche-Comte, including the sedimentary areas, justifying the necessity to realize a precise evaluation of the sanitary impact. The model will allow to study different strategies to reduce radon in houses. (N.C.)

  15. Concentration-discharge relationships under the microscope: high frequency measurement in rivers

    Science.gov (United States)

    Floury, P.; Gaillardet, J.; Bouchez, J.; Tallec, G.; Gayer, E.; Ansart, P.; Blanchouin, A.

    2017-12-01

    Concentration-discharge relationships (C-Q) of river water is a powerful tool to track the coupling between water flow and chemical reactions in the Critical Zone. C-Q have been extensively studied the last two decades. We present a new C-Q data series recorded at 40-minutes frequency by a prototype called River Lab (RL) (Floury et al., 2017). Confined in a bungalow next to the river, the RL performs an of all major dissolved species (Na+, K+, Mg2+, Ca2+, Cl-, SO42-, NO3-) using ion chromatographs, through continuous sampling and filtration of the river water. The RL was deployed in 2015 in the Orgeval hydrological Observatory (OZCAR French Research Infrastructure), an agricultural watershed underlain by carbonates, France. We present five major flood events recorded over one hydrological year. We present the C-Q for each of the flood events. We observe i) element-specific C-Q ii) C-Q loops, the size and the excentricity of which decrease with the intensity of the flood. The most reproducible C-Q patterns are observed for Na+, Mg2+, Ca2+, Cl-, SO42-, whereas K+ and NO3- present a more erratic behaviour. We discuss the chemostatic behaviour of species concentrations using a fitting by a power law function. It is likely that C-Q will depend on the time during a single flood event and also over the year. The chemostatic behaviour of each species change over the year and also during a single flood event. We focus our interpretations on the recession of each flood event, where precipitation and evapotrapiration can be considered as negligible. We propose a "grey box" aproach such as already developed from stream flow (Kirchner, 2009) but here extended to solute fluxes. Floury et al. Hydrol. Earth Syst. Sci. Discuss., doi:10.5194/hess-2017-12, 2017. Kirchner. Water Ressources Research, VOL. 45, W02429, doi:10.1029/2008WR006912, 2009.

  16. Measurements and statistical analyses of indoor radon concentrations in Tokyo and surrounding areas

    International Nuclear Information System (INIS)

    Sugiura, Shiroharu; Suzuki, Takashi; Inokoshi, Yukio

    1995-01-01

    Since the UNSCEAR report published in 1982, radiation exposure to the respiratory tract due to radon and its progeny has been regarded as the single largest contributor to the natural radiation exposure of the general public. In Japan, the measurement of radon gas concentrations in many types of buildings have been surveyed by national and private institutes. We also carried out the measurement of radon gas concentrations in different types of residential buildings in Tokyo and its adjoining prefectures from October 1988 to September 1991, to evaluate the potential radiation risk of the people living there. One or two simplified passive radon monitors were set up in each of the 34 residential buildings located in the above-mentioned area for an exposure period of 3 months each. Comparing the average concentrations in the buildings of different materials and structures, those in the concrete steel buildings were always higher than those in the wooden and the prefabricated mortared buildings. The radon concentrations were proved to become higher in autumn and winter, and lower in spring and summer. Radon concentrations in an underground room of a concrete steel building showed the highest value throughout our investigation, and statistically significant seasonal variation was detected by the X-11 method developed by the U.S. Bureau of Census. The values measured in a room at the first floor of the same concrete steel building also showed seasonal variation, but the phase of variation was different. Another multivariate analysis suggested that the building material and structure are the most important factors concerning the levels of radon concentration among other factors such as the age of the building and the use of ventilators. (author)

  17. Predicting and measurement of pH of seawater reverse osmosis concentrates

    KAUST Repository

    Waly, Tarek

    2011-10-01

    The pH of seawater reverse osmosis plants (SWRO) is the most influential parameter in determining the degree of supersaturation of CaCO3 in the concentrate stream. For this, the results of pH measurements of the concentrate of a seawater reverse osmosis pilot plant were compared with pH calculations based on the CO2-HCO3 --CO3 2- system equilibrium equations. Results were compared with two commercial software programs from membrane suppliers and also the software package Phreeqc. Results suggest that the real concentrate pH is lower than that of the feed and that none of the used programs was able to predict correctly real pH values. In addition, the effect of incorporating the acidity constant calculated for NaCl medium or seawater medium showed a great influence on the concentrate pH determination. The HCO3 - and CO3 2- equilibrium equation using acidity constants developed for seawater medium was the only method able to predict correctly the concentrate pH. The outcome of this study indicated that the saturation level of the concentrate was lower than previously anticipated. This was confirmed by shutting down the acid and the antiscalants dosing without any signs of scaling over a period of 12 months. © 2011 Elsevier B.V.

  18. Concentration and measuring Platinum Group Elements (PGE) Transfer Factor in soil and vegetations

    International Nuclear Information System (INIS)

    Adibah Sakinah Oyub

    2012-01-01

    This study was conducted to determine the concentration and to measure platinum group elements (PGE) transfer factor in environmental samples of roadside soil and vegetation. The use of vehicle catalytic converter has released platinum group elements (PGE) and other gases into the environment. Thus, roadside soil and plants were exposed to this element and has become the medium for the movement of this elements. Samples of roadside soil and vegetation were taken at various locations in UKM Bangi Toll and the concentration of platinum group elements (PGE) is determined using mass spectrometry-inductively coupled plasma (ICP-MS). Overall, the concentrations of platinum group elements (PGE), which is the element platinum (Pt) in soil was 0.016 ± 0.036 μgg -1 . While the concentration of the elements palladium (Pd) was 0.079 ± 0.019 μgg -1 and element rhodium (Rh) is at a concentration of 0.013 ± 0.020 μgg -1 . Overall, the transfer factor for the element platinum (Pt) is 1. While the transfer factor of the element palladium (Pd) is 0.96 and the element rhodium (Rh) is 1.11. In conclusion, the concentration of platinum group elements (PGE) in soils have increased. (author)

  19. Measurements of Indoor Radon Concentrations in Chaiya and Tha Chana Districts, Surat Thani Province, Thailand

    International Nuclear Information System (INIS)

    Titipornpun, K.; Titipornpun, A.; Sola, P.; Bhongsuwan, T.

    2014-01-01

    Chaiya and Tha Chana districts of Surat Thani province are located in the areas with high equivalent uranium at ground surface, which have been identified as sources of radon. A survey measurement of indoor radon concentrations was carried out in 248 houses, using CR-39 detectors in closed cups. All of the detectors were exposed to radon for forty days. After the exposure, the alpha tracks were made visible by chemical etching and counted manually under an optical microscope. The indoor concentrations in Chaiya district were found to vary from the minimum to the maximum of 4 Bq.m -3 to 88 Bq.m -3 , respectively. In Tha Chana district, the concentrations of indoor radon were varied from the minimum of 4 Bq.m -3 to the maximum of 159 Bq.m -3 . The geometric mean of indoor radon concentrations in Chaya and Tha Chana districts were found to be 26±2 Bq.m -3 and 30±2 Bq.m -3 , respectively. The overall geometric mean in the surveyed areas was 28±2 Bq.m -3 . Only in two houses (1%), the concentrations (151 and 159 Bq.m -3 ) were found to be higher than the action level recommended by the US EPA (148 Bq.m -3 ). Most houses (94%) have natural ventilation by keeping doors and windows opened during the daytime. This ventilation likely causes the low level of indoor radon concentrations.

  20. Measurements of radon daughter concentrations in structures built on or near uranium mine tailings

    International Nuclear Information System (INIS)

    Haywood, F.F.; Kerr, G.D.; Goldsmith, W.A.; Perdue, P.T.; Thorngate, J.H.

    1976-01-01

    A technique is discussed that has been used to measure air concentrations of short-lived daughters of 222 Rn in residential and commercial structures built on or near uranium mill tailings in the western part of the United States. In this technique, the concentrations of RaA, RaB, and RaC are calculated from one integral count of the RaA and two integral counts of the RaC' alpha-particle activity collected on a filter with an air sampling device. A computer program is available to calculate the concentrations of RaA, RaB, and RaC in air and to estimate the accuracy in these calculated concentrations. This program is written in the BASIC language. Also discussed in this paper are the alpha-particle spectrometer used to count activity on the air filters and the results of our radon daughter measurements in Colorado, Utah, and New Mexico. These results and results of other measurements discussed in a companion paper are now being used in a comprehensive study of potential radiation exposures to the public from uranium mill tailing piles

  1. Measurement of radon concentration in dwellings in the region of highest lung cancer incidence in India

    International Nuclear Information System (INIS)

    Zoliana, B.; Rohmingliana, P.C.; Sahoo, B.K.; Mayya, Y.S.

    2015-01-01

    Monitoring of radon exhalation from soil and its concentration in indoor is found to be helpful in many investigations such as health risk assessment and others as radiation damage to bronchial cells which eventually can be the second leading cause of lung cancer next to smoking. The fact that Aizawl District, Mizoram, India has the highest lung cancer incidence rates among males and females in Age Adjusted Rate (AAR) in India as declared by Population Based Cancer Registry Report 2008 indicates the need for quantification of radon and its anomalies attached to it. Measurement of radon concentration had been carried out inside the dwellings in Aizawl district, Mizoram. A time integrated method of measurement was employed by using a solid state nuclear track detector (SSNTD) type (LR-115 films) kept in a twin cup dosimeter for measurement of concentration of radon and thoron. The dosimeters were suspended over bed rooms or living rooms in selected dwellings. They were deployed for a period of about 120 days at a time in 63 houses which were selected according to their place of location viz. fault region, places where fossil remains were found and geologically unidentified region. After the desired period of exposure, the detectors were retrieved and chemically etched which were then counted by using a spark counter. The recorded nuclear tract densities are then converted into air concentrations of Radon and Thoron

  2. Indoor and outdoor Radon concentration measurements in Sivas, Turkey, in comparison with geological setting

    Energy Technology Data Exchange (ETDEWEB)

    Mihci, Metin [Iller Bankasi, Etud Plan ve Yol Dairesi, Opera, 06053 Ankara (Turkey); Buyuksarac, Aydin [Canakkale Onsekiz Mart University, Department of Geophysical Engineering, 17020, Canakkale (Turkey); Aydemir, Attila, E-mail: aydemir@tpao.gov.t [Turkiye Petrolleri A.O. Mustafa, Kemal Mah. 2. Cad. No: 86, 06100 Sogutozu, Ankara (Turkey); Celebi, Nilgun [Cekmece Nuclear Research and Training Centre (CNAEM), Cekmece, Istanbul (Turkey)

    2010-11-15

    Indoor and soil gas Radon ({sup 222}Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor {sup 222}Rn gas concentration values. In the second stage, soil gas {sup 222}Rn measurements were performed using an alphameter near the selected houses for the indoor measurements. Although {sup 222}Rn concentrations in Sivas were quite low in relation with the allowable limits, they are higher than the average of Turkey. Indoor and soil gas {sup 222}Rn concentration distribution maps were prepared seperately and these maps were applied onto the surface geological map. In this way, both surveys were correlated with the each other and they were interpreted in comparison with the answers of questionnaire and the geological setting of the Sivas centrum and the vicinity.

  3. Measures of ozone concentrations using passive sampling in forests of South Western Europe

    Energy Technology Data Exchange (ETDEWEB)

    Sanz, M.J. [Fundacion CEAM, Charles R. Darwin 14, Parc Tecnologic, E-46980 Paterna, Valencia (Spain)]. E-mail: mjose@ceam.es; Calatayud, V. [Fundacion CEAM, Charles R. Darwin 14, Parc Tecnologic, E-46980 Paterna, Valencia (Spain); Sanchez-Pena, G. [Servicio de Proteccion de los Montes contra Agentes Nocivos, Direccion General para la Biodiversidad, Ministerio de Medio Ambiente, Gran Via de San Francisco, 4, E-28005, Madrid (Spain)

    2007-02-15

    Ambient ozone concentrations were measured with passive samplers in the framework of the EU and UN/ECE Level II forest monitoring programme. Data from France, Italy, Luxembourg, Spain and Switzerland are reported for 2000-2002, covering the period from April to September. The number of plots increased from 67 in 2000 to 83 in 2002. The year 2001 experienced the highest ozone concentrations, reflecting more stable summer meteorological conditions. Average 6-month ozone concentrations above 45 ppb were measured this year in 40.3% of the plots, in contrast with the less than 21% measured in the other 2 years. Gradients of increasing ozone levels were observed from North to South and with altitude. Comments are made on the regional trends and on the time frame of the higher ozone episodes. Also, some recommendations enabling a better comparison between plots are provided. - Ozone concentrations in forested areas of SW Europe during the period 2000-2002 showed highest values in 2001, as well as a tendency to increase towards the South and with altitude.

  4. Measures of ozone concentrations using passive sampling in forests of South Western Europe

    International Nuclear Information System (INIS)

    Sanz, M.J.; Calatayud, V.; Sanchez-Pena, G.

    2007-01-01

    Ambient ozone concentrations were measured with passive samplers in the framework of the EU and UN/ECE Level II forest monitoring programme. Data from France, Italy, Luxembourg, Spain and Switzerland are reported for 2000-2002, covering the period from April to September. The number of plots increased from 67 in 2000 to 83 in 2002. The year 2001 experienced the highest ozone concentrations, reflecting more stable summer meteorological conditions. Average 6-month ozone concentrations above 45 ppb were measured this year in 40.3% of the plots, in contrast with the less than 21% measured in the other 2 years. Gradients of increasing ozone levels were observed from North to South and with altitude. Comments are made on the regional trends and on the time frame of the higher ozone episodes. Also, some recommendations enabling a better comparison between plots are provided. - Ozone concentrations in forested areas of SW Europe during the period 2000-2002 showed highest values in 2001, as well as a tendency to increase towards the South and with altitude

  5. The doping concentration and physical properties measurement of silicon water using tera hertz wave

    International Nuclear Information System (INIS)

    Park, Sung Hyeon; Oh, Gyung Hwan; Kim, Hak Sung

    2017-01-01

    In this study, a tera hertz time domain spectroscopy (THz-TDS) imaging technique was used to measure doping concentration and physical properties (such as refractive index and permittivity) of the doped silicon (Si) wafers. The transmission and reflection modes with an incidence angle of 30° were employed to determine the physical properties of the doped Si wafers. The doping concentrations of the prepared Si wafers were varied from 10"1"4 to 10"1"8 in both N-type and P-type cases. Finally, the correlation between the doping concentration and the power of the THz wave was determined by measuring the powers of the transmitted and reflected THz waves of the doped Si wafers. Additionally, the doped thickness, the refractive index, and permittivity of each doped Si wafer were calculated using the THz time domain waveform. The results indicate that the THz-TDS imaging technique is potentially a promising technique to measure the doping concentration as well as other optical properties (such as the refractive index and permittivity) of the doped Si wafer

  6. Measurement of the Cupric Ion Concentration Variation near Electrodes in the Copper Electroplating System

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Je Young; Chung, Bum Jin [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The heat fluxes to the side wall imposed at the upper metallic layer, are known to increase with the reduction of layer height. This 'Focusing effect' is varied by cooling condition of upper boundary and height of the metallic layer. The heat transfer experiments were replaced by mass transfer experiments based on the heat and mass transfer analogy concept. When the electroplating system is adopted as the mass transfer system, in order to simulate the different temperature conditions of top and side walls, an electrical resistance was attached to the top wall so that it is mimics hotter wall condition. Because the quantitative temperature conditions according to the electrical resistance were unknown, the methodology development is necessary. The electrical resistance was adopted to the top plate. But the quantitative temperature conditions depending on the electrical resistance were unknown. In order to overcome the limitations of mass transfer, this work tried to measure the cupric ion concentration. The methods of concentration measurement are RGB, Brightness, ICP, PIV, and Interferometry. The key of RGB, Brightness and PIV method is the clear images of the concentration boundary layer corresponding the thermal boundary layer of heat transfer. The results for ICP method can be got by taking the trace sample of a solution, accurately. The formation of patterns in the interferometry is very important. The characteristics of the interference pattern depend on the nature of the light source, the precise orientation of the mirrors, etc. The methodology of concentration measurement is still under development stage.

  7. The doping concentration and physical properties measurement of silicon water using tera hertz wave

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Hyeon; Oh, Gyung Hwan; Kim, Hak Sung [Dept. of Mechanical Convergence Engineering, Hanyang University, Seoul(Korea, Republic of)

    2017-02-15

    In this study, a tera hertz time domain spectroscopy (THz-TDS) imaging technique was used to measure doping concentration and physical properties (such as refractive index and permittivity) of the doped silicon (Si) wafers. The transmission and reflection modes with an incidence angle of 30° were employed to determine the physical properties of the doped Si wafers. The doping concentrations of the prepared Si wafers were varied from 10{sup 14} to 10{sup 18} in both N-type and P-type cases. Finally, the correlation between the doping concentration and the power of the THz wave was determined by measuring the powers of the transmitted and reflected THz waves of the doped Si wafers. Additionally, the doped thickness, the refractive index, and permittivity of each doped Si wafer were calculated using the THz time domain waveform. The results indicate that the THz-TDS imaging technique is potentially a promising technique to measure the doping concentration as well as other optical properties (such as the refractive index and permittivity) of the doped Si wafer.

  8. Measurement of the Cupric Ion Concentration Variation near Electrodes in the Copper Electroplating System

    International Nuclear Information System (INIS)

    Moon, Je Young; Chung, Bum Jin

    2016-01-01

    The heat fluxes to the side wall imposed at the upper metallic layer, are known to increase with the reduction of layer height. This 'Focusing effect' is varied by cooling condition of upper boundary and height of the metallic layer. The heat transfer experiments were replaced by mass transfer experiments based on the heat and mass transfer analogy concept. When the electroplating system is adopted as the mass transfer system, in order to simulate the different temperature conditions of top and side walls, an electrical resistance was attached to the top wall so that it is mimics hotter wall condition. Because the quantitative temperature conditions according to the electrical resistance were unknown, the methodology development is necessary. The electrical resistance was adopted to the top plate. But the quantitative temperature conditions depending on the electrical resistance were unknown. In order to overcome the limitations of mass transfer, this work tried to measure the cupric ion concentration. The methods of concentration measurement are RGB, Brightness, ICP, PIV, and Interferometry. The key of RGB, Brightness and PIV method is the clear images of the concentration boundary layer corresponding the thermal boundary layer of heat transfer. The results for ICP method can be got by taking the trace sample of a solution, accurately. The formation of patterns in the interferometry is very important. The characteristics of the interference pattern depend on the nature of the light source, the precise orientation of the mirrors, etc. The methodology of concentration measurement is still under development stage.

  9. Harmonisation of nanoparticle concentration measurements using GRIMM and TSI scanning mobility particle sizers

    International Nuclear Information System (INIS)

    Joshi, Manish; Sapra, B. K.; Khan, Arshad; Tripathi, S. N.; Shamjad, P. M.; Gupta, Tarun; Mayya, Y. S.

    2012-01-01

    Regional studies focusing on the role of atmospheric nanoparticles in climate change have gained impetus in the last decade. Several multi-institutional studies involving measurement of nanoparticles with several kinds of instruments are on the rise. It is important to harmonize these measurements as the instruments may work on different techniques or principles and are developed by different manufacturers. Scanning mobility particle sizers (SMPS) are often used to measure size distribution of nanoparticles in the airborne phase. Two such commercially available instruments namely, GRIMM and TSI-SMPS have been compared for ambient and laboratory generated conditions. A stand-alone condensation particle counter (CPC) of TSI make was used as a reference for particle concentration measurements. The consistency of the results in terms of mean size and geometric standard deviation was seen to be excellent for both the SMPSs, with GRIMM always showing slightly (approximately 10 %) lower mean size. The integrated number concentration from GRIMM-SMPS was seen to be closer to stand-alone reference CPC compared to TSI-SMPS, for an ambient overnight comparison. However, a concentration-dependent response, i.e. the variations between the two instruments increasing with the concentration, was observed and possible reasons for this have been suggested. A separate experiment was performed for studying the modifying effect of diffusion dryer and sheath air dryer on the measured aerosol size spectra. A significant hygroscopic growth was noted when diffusion dryer was attached to one of the SMPS. The introduction of sheath air dryer in GRIMM-SMPS produced a significant shift towards lower mean size. These results have been compared and discussed with the recent inter-comparison results to strengthen and harmonize the measurement protocols.

  10. Harmonisation of nanoparticle concentration measurements using GRIMM and TSI scanning mobility particle sizers

    Science.gov (United States)

    Joshi, Manish; Sapra, B. K.; Khan, Arshad; Tripathi, S. N.; Shamjad, P. M.; Gupta, Tarun; Mayya, Y. S.

    2012-12-01

    Regional studies focusing on the role of atmospheric nanoparticles in climate change have gained impetus in the last decade. Several multi-institutional studies involving measurement of nanoparticles with several kinds of instruments are on the rise. It is important to harmonize these measurements as the instruments may work on different techniques or principles and are developed by different manufacturers. Scanning mobility particle sizers (SMPS) are often used to measure size distribution of nanoparticles in the airborne phase. Two such commercially available instruments namely, GRIMM and TSI-SMPS have been compared for ambient and laboratory generated conditions. A stand-alone condensation particle counter (CPC) of TSI make was used as a reference for particle concentration measurements. The consistency of the results in terms of mean size and geometric standard deviation was seen to be excellent for both the SMPSs, with GRIMM always showing slightly (approximately 10 %) lower mean size. The integrated number concentration from GRIMM-SMPS was seen to be closer to stand-alone reference CPC compared to TSI-SMPS, for an ambient overnight comparison. However, a concentration-dependent response, i.e. the variations between the two instruments increasing with the concentration, was observed and possible reasons for this have been suggested. A separate experiment was performed for studying the modifying effect of diffusion dryer and sheath air dryer on the measured aerosol size spectra. A significant hygroscopic growth was noted when diffusion dryer was attached to one of the SMPS. The introduction of sheath air dryer in GRIMM-SMPS produced a significant shift towards lower mean size. These results have been compared and discussed with the recent inter-comparison results to strengthen and harmonize the measurement protocols.

  11. Specific wavelength colorimeter. [for measuring given solute concentration in test sample

    Science.gov (United States)

    Brawner, C. C.; Mcdavid, L. S.; Walsh, J. M. (Inventor)

    1974-01-01

    A self contained, specific wavelength, single beam colorimeter is described for direct spectrophotometric measurement of the concentration of a given solute in a test sample. An electrical circuit employing a photoconductive cell converts the optical output into a linear, directly readable meter output. The colorimeter is simple to operate and is adapted for use in zero gravity conditions. In a specific application, the colorimeter is designed to analyze the concentration of iodine in potable water carried aboard a space vehicle such as the 4B stage of Skylab.

  12. Analysis of predicted and measured performance of an integrated compound parabolic concentrator (ICPC)

    Energy Technology Data Exchange (ETDEWEB)

    Winston, R.; O' Gallagher, J.J.; Muschaweck, J.; Mahoney, A.R.; Dudley, V.

    1999-07-01

    A variety of configurations of evacuated Integrated Compound Parabolic Concentrator (ICPC) tubes have been under development for many years. A particularly favorable optical design corresponds to the unit concentration limit for a fin CPC solution which is then coupled to a practical, thin, wedge-shaped absorber. Prototype collector modules using tubes with two different fin orientations (horizontal and vertical) have been fabricated and tested. Comprehensive measurements of the optical characteristics of the reflector and absorber have been used together with a detailed ray trace analysis to predict the optical performance characteristics of these designs. The observed performance agrees well with the predicted performance.

  13. Measure of hydrogen concentration profile in materials by resonant nuclear reactions

    International Nuclear Information System (INIS)

    Livi, R.P.; Zawislak, F.C.; Acquadro, J.C.

    1986-01-01

    The technique for determining the profile of hydrogen concentration in proximities of the surface of materials, is presented. The preliminary measurements were done, using the Pelletron accelerator at Sao Paulo University (USP), in Brazil, for the resonant-nuclear reaction 1 H( 19 F, α γ) 16 O. By using this reaction the technique is sensitive for concentrations above 500 ppm, which could be reduced to 100 ppm through special shieldings and other techniques to reduce the background radiation. (M.C.K.) [pt

  14. Measurement of Rn-222 concentrations in building materials used in jordan

    International Nuclear Information System (INIS)

    Ismail, A.M.; Abumyrad, K.M.; Kullab, M.K.; Albataina, B.A.

    1995-01-01

    In this work, the concentrations of the radiative inert gas Rn-222 emanated from the building materials that are commonly in jordan have been studied. For this purpose, samples of ten jordanian building materials of different masses were prepared in plastic cans sealed to passive integrated dosimeters containing CR-39 solid state nuclear track detectors which are very sensitive to alpha-particles. The Rn-222 concentrations in these samples range from 137 Bq/m 3 to 267 Bq/m 3 with an average of 189 Bq/m 3 . These levels were found to be consistent with those measured by other workers in other countries. 4 figs., 2 tabs

  15. Intercomparison of measurements of NO2 concentrations in the atmosphere simulation chamber SAPHIR during the NO3Comp campaign

    Directory of Open Access Journals (Sweden)

    H. Fuchs

    2010-01-01

    Full Text Available NO2 concentrations were measured by various instruments during the NO3Comp campaign at the atmosphere simulation chamber SAPHIR at Forschungszentrum Jülich, Germany, in June 2007. Analytical methods included photolytic conversion with chemiluminescence (PC-CLD, broadband cavity ring-down spectroscopy (BBCRDS, pulsed cavity ring-down spectroscopy (CRDS, incoherent broadband cavity-enhanced absorption spectroscopy (IBB\\-CEAS, and laser-induced fluorescence (LIF. All broadband absorption spectrometers were optimized for the detection of the main target species of the campaign, NO3, but were also capable of detecting NO2 simultaneously with reduced sensitivity. NO2 mixing ratios in the chamber were within a range characteristic of polluted, urban conditions, with a maximum mixing ratio of approximately 75 ppbv. The overall agreement between measurements of all instruments was excellent. Linear fits of the combined data sets resulted in slopes that differ from unity only within the stated uncertainty of each instrument. Possible interferences from species such as water vapor and ozone were negligible under the experimental conditions.

  16. Optical measurements of atomic oxygen concentration, temperature and nitric oxide production rate in flames

    Science.gov (United States)

    Myhr, Franklin Henry

    An optical method for measuring nitric oxide (NO) production rates in flames was developed and characterized in a series of steady, one-dimensional, atmospheric-pressure laminar flames of 0.700 Hsb2/0.199 Nsb2/0.101 COsb2 or 0.700 CHsb4/0.300 Nsb2 (by moles) with dry air, with equivalence ratios from 0.79 to 1.27. Oxygen atom concentration, (O), was measured by two-photon laser-induced fluorescence (LIF), temperature was measured by ultraviolet Rayleigh scattering, and nitrogen concentration was calculated from supplied reactant flows; together this information was used to calculate the NO production rate through the thermal (Zel'dovich) mechanism. Measurements by two other techniques were compared with results from the above method. In the first comparison, gas sampling was used to measure axial NO concentration profiles, the slopes of which were multiplied by velocity to obtain total NO production rates. In the second comparison, LIF measurements of hydroxyl radical (OH) were used with equilibrium water concentrations and a partial equilibrium assumption to find (O). Nitric oxide production rates from all three methods agreed reasonably well. Photolytic interference was observed during (O) LIF measurements in all of the flames; this is the major difficulty in applying the optical technique. Photolysis of molecular oxygen in lean flames has been well documented before, but the degree of interference observed in the rich flames suggests that some other molecule is also dissociating; the candidates are OH, CO, COsb2 and Hsb2O. An extrapolative technique for removing the effects of photolysis from (O) LIF measurements worked well in all flames where NO production was significant. Using the optical method to measure NO production rates in turbulent flames will involve a tradeoff among spatial resolution, systematic photolysis error, and random shot noise. With the conventional laser system used in this work, a single pulse with a resolution of 700 mum measured NO

  17. Radioisotope labeling technique for vapor density measurements of volatile inorganic species

    International Nuclear Information System (INIS)

    Peterson, E.J.; Caird, J.A.; Hessler, J.P.; Hoekstra, H.R.; Williams, C.W.

    1979-01-01

    A new method for complexed metal ion vapor density measurement involving labeling the metal ions of interest with a radioactive isotope is described. The isotope chosen in the present work is unstable and leads to emission of a characteristic γ ray. Thus the γ-counting rate was related to the number density of complexed metal ions in the vapor phase. This technique is applicable to the study of any volatile inorganic species, but in the present study has been used to measure vapor densities of complex species in the TbCl 3 -AlCl 3 system by using tracer 160 Tb. 4 figures, 2 tables

  18. Measuring reactive oxygen and nitrogen species with fluorescent probes: challenges and limitations

    Science.gov (United States)

    Kalyanaraman, Balaraman; Darley-Usmar, Victor; Davies, Kelvin J.A.; Dennery, Phyllis A.; Forman, Henry Jay; Grisham, Matthew B.; Mann, Giovanni E.; Moore, Kevin; Roberts, L. Jackson; Ischiropoulos, Harry

    2013-01-01

    The purpose of this position paper is to present a critical analysis of the challenges and limitations of the most widely used fluorescent probes for detecting and measuring reactive oxygen and nitrogen species. Where feasible, we have made recommendations for the use of alternate probes and appropriate analytical techniques that measure the specific products formed from the reactions between fluorescent probes and reactive oxygen and nitrogen species. We have proposed guidelines that will help present and future researchers with regard to the optimal use of selected fluorescent probes and interpretation of results. PMID:22027063

  19. Does application of the Rosiwal principle to lunar soils require that concentrations of solar-wind-implanted species be grain-size independent

    International Nuclear Information System (INIS)

    Becker, R.H.

    1977-01-01

    A reconsideration of the application of the Rosiwal Principle to lunar soils indicates a flaw in arguments put forth previously by Criswell. Specifically, by introducing a boundary condition which must exist at the lunar surface, it is shown that concentrations of solar-wind-implanted species showing a dependence on grain size may be able to develop in soils at concentration levels below those required for saturation of grain surfaces. As a result, observed grain-size-dependent concentrations of solar-wind species in lunar soils do not necessarily require the exposure time scales or solar-wind fluxes deduced from the arguments of Criswell. (Auth.)

  20. Optimized measurement of radium-226 concentration in liquid samples with radon-222 emanation

    International Nuclear Information System (INIS)

    Perrier, Frédéric; Aupiais, Jean; Girault, Frédéric; Przylibski, Tadeusz A.; Bouquerel, Hélène

    2016-01-01

    Measuring radium-226 concentration in liquid samples using radon-222 emanation remains competitive with techniques such as liquid scintillation, alpha or mass spectrometry. Indeed, we show that high-precision can be obtained without air circulation, using an optimal air to liquid volume ratio and moderate heating. Cost-effective and efficient measurement of radon concentration is achieved by scintillation flasks and sufficiently long counting times for signal and background. More than 400 such measurements were performed, including 39 dilution experiments, a successful blind measurement of six reference test solutions, and more than 110 repeated measurements. Under optimal conditions, uncertainties reach 5% for an activity concentration of 100 mBq L"−"1 and 10% for 10 mBq L"−"1. While the theoretical detection limit predicted by Monte Carlo simulation is around 3 mBq L"−"1, a conservative experimental estimate is rather 5 mBq L"−"1, corresponding to 0.14 fg g"−"1. The method was applied to 47 natural waters, 51 commercial waters, and 17 wine samples, illustrating that it could be an option for liquids that cannot be easily measured by other methods. Counting of scintillation flasks can be done in remote locations in absence of electricity supply, using a solar panel. Thus, this portable method, which has demonstrated sufficient accuracy for numerous natural liquids, could be useful in geological and environmental problems, with the additional benefit that it can be applied in isolated locations and in circumstances when samples cannot be transported. - Highlights: • Radium-226 concentration measured with optimized accumulation in a container. • Radon-222 in air measured precisely with scintillation flasks and long countings. • Method tested by repetition tests, dilution experiments, and successful blind tests. • Estimated conservative detection limit without pre-concentration is 5 mBq L"−"1. • Method is portable, cost

  1. Combination scattering of dissociating gas applied to measurements of temperature and concentration of components

    International Nuclear Information System (INIS)

    Pashkov, V.A.; Kurganova, F.I.; Grishchuk, M.Kh.

    1987-01-01

    The method to calculate the combination scattering power of the components of the dissociating N 2 O 4 ↔ 2NO 2 → 2NO+O 2 gas subjected to the laser radiation effect is given. The combination scattering power has been calculated for temperatures 400-600 K, pressures 1-3 MPa, with the neodymium laser (λ=1.06 μm) as a source and the possibility of measuring the local temperatures and concentration of the given gas components with the help of the combination scattering has been analysed. It follows from the calculated data that combination scattering power of N 2 O 4 ↔ 2NO 2 ↔ 2NO+O 2 gas in excitation with the neodymium laser as a source is sufficient for detection. Gas temperature is likely to be measured with the minimum error relative to stokes and anti-stokes bands of the combination scattering, produced by nitrogen tetroxide. From calculated data it also follows that measurement of NO 2 concentration in the range 400-600 K is possible. At the same time combination scattering power, produced by NO and O 2 components is sufficient for measurement merely with the concentration of the components of the order of 10 18 molecules/cm 3 guaranteed in static conditions only at N 2 O 4 ↔ 2NO 2 ↔ 2NO+O 2 gas temperature 500 K and higher

  2. Development of an instantaneous local fuel-concentration measurement probe: an engine application

    Science.gov (United States)

    Guibert, P.; Boutar, Z.; Lemoyne, L.

    2003-11-01

    This work presents a new tool which can deliver instantaneous local measurements of fuel concentration in an engine cylinder with a high temporal resolution, particularly during compression strokes. Fuel concentration is represented by means of equivalence fuel-air ratio, i.e. the real engine mass ratio of fuel to air divided by the same ratio in ideal stoichiometry conditions. Controlling the mixture configuration for any strategy in a spark ignition engine and for auto-ignition combustion has a dominant effect on the subsequent processes of ignition, flame propagation and auto-ignition combustion progression, pollutant formation under lean or even stoichiometric operating conditions. It is extremely difficult, under a transient operation, to control the equivalence air/fuel ratio precisely at a required value and at the right time. This requires the development of a highly accurate equivalence air/fuel ratio control system and a tool to measure using crank angle (CA) resolution. Although non-intrusive laser techniques have considerable advantages, they are most of the time inappropriate due to their optical inaccessibility or the complex experimental set-up involved. Therefore, as a response to the demand for a relatively simple fuel-concentration measurement system a probe is presented that replaces a spark plug and allows the engine to run completely normally. The probe is based on hot-wire like apparatus, but involves catalytic oxidation at the wire surface. The development, characteristics and calibration of the probe are presented followed by applications to in-cylinder engine measurements.

  3. Uncertainty propagation for the coulometric measurement of the plutonium concentration in MOX-PU4.

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2017-11-07

    This GUM WorkbenchTM propagation of uncertainty is for the coulometric measurement of the plutonium concentration in a Pu standard material (C126) supplied as individual aliquots that were prepared by mass. The C126 solution had been prepared and as aliquoted as standard material. Samples are aliquoted into glass vials and heated to dryness for distribution as dried nitrate. The individual plutonium aliquots were not separated chemically or otherwise purified prior to measurement by coulometry in the F/H Laboratory. Hydrogen peroxide was used for valence adjustment. The Pu assay measurement results were corrected for the interference from trace iron in the solution measured for assay. Aliquot mass measurements were corrected for air buoyancy. The relative atomic mass (atomic weight) of the plutonium from X126 certoficate was used. The isotopic composition was determined by thermal ionization mass spectrometry (TIMS) for comparison but not used in calculations.

  4. Physical and Instrumental Considerations in the Use of Lithium Phthalocyanine for Measurements of the Concentration of the Oxygen

    Science.gov (United States)

    Smirnov, A. I.; Norby, S. W.; Walczak, T.; Liu, K. J.; Swartz, H. M.

    The use of crystals of lithium phthalocyanine (LiPc) to measure the concentration of oxygen in vivo and in vitro by electron paramagnetic resonance leads to experimental constraints due to the very narrow EPR lines that may occur (as narrow as 11-13 mG in the absence of O 2), distortions induced by the automatic frequency control system, anisotropy in the spectra (orientation-dependent linewidth is 11-17 mG in the absence of O 2), microwave power saturation, and the effect of physiological motion. These constraints can be overcome if recognized. This article highlights the experimental and theoretical basis of these properties of the EPR signal of LiPc and suggests some technical solutions. It is most important to recognize that paramagnetic species such as LiPc present problems that are not commonly encountered in EPR spectroscopy.

  5. Phase-conjugate resonant holographic interferometry applied to NH concentration measurements in a 2D diffusion flame

    Energy Technology Data Exchange (ETDEWEB)

    Tzannis, A P; Beaud, P; Frey, H M; Gerber, T; Mischler, B; Radi, P P [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    Resonant Holographic Interferometry is a method based on the anomalous dispersion of light having a frequency close to an electronic transition of a molecule. We propose a novel single-laser, two-colour setup for recording resonant holograms and apply it to 2D species concentration measurements. The second colour is generated by optical phase-conjugation from Stimulated Brillouin scattering in a cell. Phase-Conjugate Resonant Holographic Interferometry (PCRHI) is demonstrated in a 2D NH{sub 3}/O{sub 2} flame yielding interferograms that contain information on the NH radical distribution in the flame. Experimental results are quantified by applying a numerical computation of the Voigt profiles. (author) 1 fig., 3 refs.

  6. Uncertainty associated with the gravimetric measurement of particulate matter concentration in ambient air.

    Science.gov (United States)

    Lacey, Ronald E; Faulkner, William Brock

    2015-07-01

    This work applied a propagation of uncertainty method to typical total suspended particulate (TSP) sampling apparatus in order to estimate the overall measurement uncertainty. The objectives of this study were to estimate the uncertainty for three TSP samplers, develop an uncertainty budget, and determine the sensitivity of the total uncertainty to environmental parameters. The samplers evaluated were the TAMU High Volume TSP Sampler at a nominal volumetric flow rate of 1.42 m3 min(-1) (50 CFM), the TAMU Low Volume TSP Sampler at a nominal volumetric flow rate of 17 L min(-1) (0.6 CFM) and the EPA TSP Sampler at the nominal volumetric flow rates of 1.1 and 1.7 m3 min(-1) (39 and 60 CFM). Under nominal operating conditions the overall measurement uncertainty was found to vary from 6.1x10(-6) g m(-3) to 18.0x10(-6) g m(-3), which represented an uncertainty of 1.7% to 5.2% of the measurement. Analysis of the uncertainty budget determined that three of the instrument parameters contributed significantly to the overall uncertainty: the uncertainty in the pressure drop measurement across the orifice meter during both calibration and testing and the uncertainty of the airflow standard used during calibration of the orifice meter. Five environmental parameters occurring during field measurements were considered for their effect on overall uncertainty: ambient TSP concentration, volumetric airflow rate, ambient temperature, ambient pressure, and ambient relative humidity. Of these, only ambient TSP concentration and volumetric airflow rate were found to have a strong effect on the overall uncertainty. The technique described in this paper can be applied to other measurement systems and is especially useful where there are no methods available to generate these values empirically. This work addresses measurement uncertainty of TSP samplers used in ambient conditions. Estimation of uncertainty in gravimetric measurements is of particular interest, since as ambient particulate

  7. Quantification of Concentration of Microalgae Anabaena Cylindrica, Coal-bed Methane Water Isolates Nannochloropsis Gaditana and PW-95 in Aquatic Solutions through Hyperspectral Reflectance Measurement and Analytical Model Establishment

    Science.gov (United States)

    Zhou, Z.; Zhou, X.; Apple, M. E.; Spangler, L.

    2017-12-01

    Three species of microalgae, Anabaena cylindrica (UTEX # 1611), coal-bed methane water isolates Nannochloropsis gaditana and PW-95 were cultured for the measurements of their hyperspectral profiles in different concentrations. The hyperspectral data were measured by an Analytical Spectral Devices (ASD) spectroradiomter with the spectral resolution of 1 nanometer over the wavelength ranges from 350nm to 1050 nm for samples of microalgae of different concentration. Concentration of microalgae was measured using a Hemocytometer under microscope. The objective of this study is to establish the relation between spectral reflectance and micro-algal concentration so that microalgae concentration can be measured remotely by space- or airborne hyperspectral or multispectral sensors. Two types of analytical models, linear reflectance-concentration model and Lamber-Beer reflectance-concentration model, were established for each species. For linear modeling, the wavelength with the maximum correlation coefficient between the reflectance and concentrations of algae was located and then selected for each species of algae. The results of the linear models for each species are shown in Fig.1(a), in which Refl_1, Refl_2, and Refl_3 represent the reflectance of Anabaena, N. Gaditana, and PW-95 respectively. C1, C2, and C3 represent the Concentrations of Anabaena, N. Gaditana, and PW-95 respectively. The Lamber-Beer models were based on the Lambert-Beer Law, which states that the intensity of light propagating in a substance dissolved in a fully transmitting solvent is directly proportional to the concentration of the substance and the path length of the light through the solution. Thus, for the Lamber-Beer modeling, a wavelength with large absorption in red band was selected for each species. The results of Lambert-Beer models for each species are shown in Fig.1(b). Based on the Lamber-Beer models, the absorption coefficient for the three different species will be quantified.

  8. Measurements of CaF2 concentration in fluorite ore using thermoluminescence techniques

    International Nuclear Information System (INIS)

    Lembo, L.; Maestri, G.; Pimpinella, M.; Benzi, V.; Muntoni, C.

    1990-01-01

    Fluorite powder is produced by means of a flotation process on crude ore extracted by the mines. A full automation of the flotation plant would reduce the operating cost and improve the quality and recovery of fluorite production. However, taking into account that the efficiency of a flotation cycle is directly dependent on the CaF 2 content in the concentrate and tail products, this automation requires a quasi-real-time quantitative analysis of CaF 2 concentration in the floated pulp. The feasibility was studied of using a thermoluminescence technique as an on-line analysis method to measure the CaF 2 concentration during the flotation cycle. A first set of experimental conditions to determine CaF 2 content in acid-grade fluorspar has been already developed and the preliminary results so far obtained are presented. (author)

  9. Measurement of natural and {sup 137}Cs radioactivity concentrations at Izmit Bay (Marmara Sea), Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Öksüz, İ., E-mail: ibrahim-ksz@yahoo.com; Güray, R. T., E-mail: tguray@kocaeli.edu.tr; Özkan, N., E-mail: nozkan@kocaeli.edu.tr; Yalçin, C., E-mail: caner.yalcin@kocaeli.edu.tr [Kocaeli University, Department of Physics, Umuttepe 41380, Kocaeli (Turkey); Ergül, H. A., E-mail: halim.ergul@kocaeli.edu.tr; Aksan, S., E-mail: serdar.aksan@kocaeli.edu.tr [Kocaeli University, Department of Biology, Umuttepe 41380, Kocaeli (Turkey)

    2016-03-25

    In order to determine the radioactivity level at Izmit Bay Marmara Sea, marine sediment samples were collected from five different locations. The radioactivity concentrations of naturally occurring {sup 238}U, {sup 232}Th and {sup 40}K isotopes and also that of an artificial isotope {sup 137}Cs were measured by using gamma-ray spectroscopy. Preliminary results show that the radioactivity concentrations of {sup 238}U and {sup 232}Th isotopes are lower than the average worldwide values while the radioactivity concentrations of the {sup 40}K are higher than the average worldwide value. A small amount of {sup 137}Cs contamination, which might be caused by the Chernobyl accident, was also detected.

  10. Measurements of the radon-222 and its daughters concentrations throughout Gaza strip, Palestine

    International Nuclear Information System (INIS)

    Rasas, M.F.; Yassin, S.S.; Shabat, M.M.

    2005-01-01

    High Radon levels are present in the granite and grandiositic rocks that. spread in sand dunes along coast of Gaza. Such materials are rich in uranium and T widely used in the construction of dwelling in the Gaza, and their contribution to high indoor Radon levels is most relevant.The present work aims to investigate approaches, measures and detection of indoor Radon level throughout Gaza Strip. Five hundred CR-39 dosimeters were distributed over six locations in the middle Yv-region of Gaza Strip. Results suggest that Radon concentrations range from l3.36 to 83.82 Bq/m 3 and a maximum value of 97.01 Bq/m 3 .The average Radon concentrations was 37.83 Bq/m 3 with standard deviation of 11.23.The results provide a framework for future studies that include a large, broader survey of Radon concentration in Palestine

  11. Sedimentology models from activity concentration measurements: application to the 'Bay of Cadiz' Natural Park (SW Spain)

    International Nuclear Information System (INIS)

    Ligero, R.A.; Vidal, J.; Melendez, M.J.; Hamani, M.; Casas-Ruiz, M.

    2009-01-01

    A previous study on seabed sediments of the Bay of Cadiz (SW of Spain) enabled us to identify several relations between sedimentological variables and activity concentrations of environmental radionuclides such as 137 Cs, 226 Ra, 232 Th and 40 K. In this paper the study has been extended to a large neighbouring inter-tidal area in order to establish if the above mentioned models can be generalized. As a result we have determined that the measured activity concentrations are closely to the values predicted by the theoretical models (correlation coefficient range = 0.85-0.93). Furthermore, the proposal model for granulometric facies as a function of activity concentrations of the abovementioned radionuclides provides for the sediments distribution a representation which agrees with the values of the tidal energy distribution obtained using numeric models calibrated with experimental data from current meters and water level recorders

  12. Application of image analyzer for radon concentration measurement by nuclear track detector

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Vukovic, J.; Novakovic, V.; Tasic, M.

    1998-01-01

    Radon concentration measurements were performed by determination of alpha tracks density in NTD of polymer type (Allyl diglycol polycarbonate - ADC Intercast EC, Parma). NTD plates were exposed to Rn, during 72 days in low level laboratory (LLL) at the Institute of Physics, Belgrade. Therefore, they were etched in 6N - NaOH water solution during 8 h at bath temperature of 70 0 C. The analyses of the alpha tracks was made by optical microscope and semiquantitative image analyzer using video camera digitizer attached to Pentium PC with software Ozaria V2.5. According to the determined mean track density value, ρmean=74210 tracks/cm 2 (background track density ρb=123 tracks/cm 2 ) Rn concentration was calculated to be 1174 Bq/m 3 . Obtained higher value than global - normal indoor Rn concentration might be the consequence of the temperature difference in LLL and outdoor. (author)

  13. Exposition by inhalation to the formaldehyde in the air. Source, measures and concentrations; Exposition par inhalation au formaldehyde dans l'air. Source, mesures et concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Del Gratta, F.; Durif, M.; Fagault, Y.; Zdanevitch, I

    2004-12-15

    This document presents the main techniques today available to characterize the formaldehyde concentrations in the air for different contexts: urban and rural areas or around industrial installations but also indoor and occupational area. It provides information to guide laboratories and research departments. A synthesis gives also the main emissions sources of these compounds as reference concentrations measured in different environments. (A.L.B.)

  14. Development of fast measurements of concentration of NORM U-238 by HPGe

    Science.gov (United States)

    Cha, Seokki; Kim, Siu; Kim, Geehyun

    2017-02-01

    Naturally Occureed Radioactive Material (NORM) generated from the origin of earth can be found all around us and even people who are not engaged in the work related to radiation have been exposed to unnecessary radiation. This NORM has a potential risk provided that is concentrated or transformed by artificial activities. Likewise, a development of fast measruement method of NORM is emerging to prevent the radiation exposure of the general public and person engaged in the work related to the type of business related thereto who uses the material in which NORM is concentrated or transfromed. Based on such a background, many of countries have tried to manage NORM and carried out regulatory legislation. To effienctly manage NORM, there is need for developing new measurement to quickly and accurately analyze the nuclide and concentration. In this study, development of the fast and reliable measurement was carried out. In addition to confirming the reliability of the fast measurement, we have obtained results that can suggest the possibility of developing another fast measurement. Therefore, as a follow-up, it is possible to develop another fast analytical measurement afterwards. The results of this study will be very useful for the regulatory system to manage NORM. In this study, a review of two indirect measurement methods of NORM U-238 that has used HPGe on the basis of the equilibrium theory of relationships of mother and daughter nuclide at decay-chain of NORM U-238 has been carried out. For comparative study(in order to know reliabily), direct measurement that makes use of alpha spectrometer with complicated pre-processing process was implemented.

  15. Passerine morphology: external measurements of approximately one-quarter of passerine bird species.

    Science.gov (United States)

    Ricklefs, Robert E

    2017-05-01

    Studies of community organization and clade diversification that include functional traits have become an important component of the analysis of ecological and evolved systems. Such studies frequently are limited by availability of consistently collected data. Here, I present a data set including eight measurements of the external morphology of 1642 species, roughly one-quarter of all passerine birds (Aves: Order Passeriformes), from all parts of the world, characterizing the relative proportions of the wing, tail, legs, and beak. Specimens were measured opportunistically over the past 40 years in museums in the United States and Europe. Numbers of individuals measured per species vary from one to dozens in some cases. Measurements for males and females of sexually size-dimorphic species are presented separately. The measurements include total length, the lengths of the wing, tail, tarsus, and middle toe, and the length, breadth, and depth of the beak. Particular attention was paid to obtaining a broad representation of passerine higher taxa, with special interest in small families and subfamilies of passerines, as well as species produced by evolutionary radiations of birds in archipelagoes, including the Galapagos, Hawaii, and the Lesser Antilles. Taxonomy follows the Taxonomy in Flux (TIF) checklist as well as the World Bird List of the International Ornithological Council. Geographic distributions are summarized from Edwards's Coded List of Birds of the World. Coverage of taxa and geographic regions varies and reflects the changing interests of the author over the past four decades. North American and South American species are particularly well represented in the sample, as well as species belonging to the families Tyrannidae, Furnariidae, Thamnophilidae, Mimidae, Sturnidae, Fringillidae, Parulidae, Icteridae, Cardinalidae, and Thraupidae. © 2017 by the Ecological Society of America.

  16. Examination of a high resolution laser optical plankton counter and FlowCAM for measuring plankton concentration and size

    Science.gov (United States)

    Kydd, Jocelyn; Rajakaruna, Harshana; Briski, Elizabeta; Bailey, Sarah

    2018-03-01

    Many commercial ships will soon begin to use treatment systems to manage their ballast water and reduce the global transfer of harmful aquatic organisms and pathogens in accordance with upcoming International Maritime Organization regulations. As a result, rapid and accurate automated methods will be needed to monitoring compliance of ships' ballast water. We examined two automated particle counters for monitoring organisms ≥ 50 μm in minimum dimension: a High Resolution Laser Optical Plankton Counter (HR-LOPC), and a Flow Cytometer with digital imaging Microscope (FlowCAM), in comparison to traditional (manual) microscopy considering plankton concentration, size frequency distributions and particle size measurements. The automated tools tended to underestimate particle concentration compared to standard microscopy, but gave similar results in terms of relative abundance of individual taxa. For most taxa, particle size measurements generated by FlowCAM ABD (Area Based Diameter) were more similar to microscope measurements than were those by FlowCAM ESD (Equivalent Spherical Diameter), though there was a mismatch in size estimates for some organisms between the FlowCAM ABD and microscope due to orientation and complex morphology. When a single problematic taxon is very abundant, the resulting size frequency distribution curves can become skewed, as was observed with Asterionella in this study. In particular, special consideration is needed when utilizing automated tools to analyse samples containing colonial species. Re-analysis of the size frequency distributions with the removal of Asterionella from FlowCAM and microscope data resulted in more similar curves across methods with FlowCAM ABD having the best fit compared to the microscope, although microscope concentration estimates were still significantly higher than estimates from the other methods. The results of our study indicate that both automated tools can generate frequency distributions of particles

  17. Determination of DPPH Radical Oxidation Caused by Methanolic Extracts of Some Microalgal Species by Linear Regression Analysis of Spectrophotometric Measurements

    Directory of Open Access Journals (Sweden)

    Ulf-Peter Hansen

    2007-10-01

    Full Text Available The demonstrated modified spectrophotometric method makes use of the 2,2-diphenyl-1-picrylhydrazyl (DPPH radical and its specific absorbance properties. Theabsorbance decreases when the radical is reduced by antioxidants. In contrast to otherinvestigations, the absorbance was measured at a wavelength of 550 nm. This wavelengthenabled the measurements of the stable free DPPH radical without interference frommicroalgal pigments. This approach was applied to methanolic microalgae extracts for twodifferent DPPH concentrations. The changes in absorbance measured vs. the concentrationof the methanolic extract resulted in curves with a linear decrease ending in a saturationregion. Linear regression analysis of the linear part of DPPH reduction versus extractconcentration enabled the determination of the microalgae’s methanolic extractsantioxidative potentials which was independent to the employed DPPH concentrations. Theresulting slopes showed significant differences (6 - 34 μmol DPPH g-1 extractconcentration between the single different species of microalgae (Anabaena sp.,Isochrysis galbana, Phaeodactylum tricornutum, Porphyridium purpureum, Synechocystissp. PCC6803 in their ability to reduce the DPPH radical. The independency of the signal on the DPPH concentration is a valuable advantage over the determination of the EC50 value.

  18. Field instruments for real time in-situ crude oil concentration measurements

    International Nuclear Information System (INIS)

    Fuller, C.B.; Bonner, J.S.; Page, C.A.; Arrambide, G.; Sterling, M.C.Jr.; Ojo, T.O.

    2003-01-01

    Accidental oil spills, contaminant release during resuspension, storms, and harmful algal blooms are all episodic events that can effect coastal margins. It is important to quantitatively describe water and ecological quality evolution and predict the impact to these areas by such events, but traditional sampling methods miss environmental activity during cyclical events. This paper presents a new sampling approach that involves continuous, real-time in-situ monitoring to provide data for development of comprehensive modeling protocols. It gives spill response coordinators greater assurance in making decisions using the latest visualization tools which are based on a good understanding of the physical processes at work in pulsed events. Five sensors for rapid monitoring of crude oil concentrations in aquatic systems were described. The in-situ and ex-situ sensors can measure plume transport and estimate polycyclic aromatic hydrocarbon exposure concentrations to assess risk of toxicity. A brief description and evaluation of the following 5 sensors was provided: the LISST-100 by Sequoia Instrument, a submersible multi-angle laser scattering instrument; the AU-10 field fluorometer by Turner Designs, an ex-situ single wavelength fluorometer; the Flashlamp by WET Labs Inc., an in-situ single wavelength fluorometer; and, the ECO-FL3 and SAFire by WET Labs Inc., two in-situ multiple wavelength fluorometers. These instruments were used to analyze crude oil emissions of various concentrations. All of the instruments followed a linear response within the tested concentration range. At the lowest concentrations the LISST-100 was not as effective as the fluorometers because of limited particle volume for scatter. For the AU-10 field fluorometer, the highest concentrations tested were above the measurement range of the instrument. 6 refs., 5 figs

  19. Concentrations and size distributions of fine aerosol particles measured at roof level in urban zone

    Science.gov (United States)

    Despiau, S.; Croci, D.

    2007-05-01

    During the experimental Field Experiments to Constrain Models of Atmospheric Pollution and Transport of Emissions (ESCOMPTE) campaign in June-July 2001, concentrations and size distributions of fine particles (14-722 nm) were measured at roof level in downtown Marseille (France). Part of the campaign was dedicated to the study of aerosol behavior in relation to strong photochemical events (which were identified as "IOP" days) and their regional modeling. The analysis of the concentration variations and the evolution of average diurnal size distribution showed that an "IOP day" is not characterized by a specific concentration or its variation, nor by a specific evolution of the average size distribution. The morning traffic rush is detected at roof level by a net increase in particle concentration over the whole size range measured, indicating a production of ultrafine particles by the traffic but also the raising to roof level of particles of the accumulation mode. The increase is observed about 1 hour after the traffic peak at street level, which is characterized by strong increases in NOx and CO concentrations. The corresponding flux of particles at roof level has been estimated around 3 × 104 cm-2 s-1. A specific signature characterized by a strong and rapid burst of concentration (factor 2 to 4 in 15 min) of particles between 25 and 50 nm, independent of the traffic source, has been detected on six occasions during the campaign. These events occur systematically around noon, in cases of strong radiation, low relative humidity, and common wind direction. Despite the high-diameter value of these particles, it is suggested that they could result from a specific "secondary aerosol process" event involving ozone, biogenic, and/or anthropogenic gas precursors like iodine and VOCs.

  20. Results of measurements of particulate matter concentrations inside a pig fattening facility

    Directory of Open Access Journals (Sweden)

    Ulens, T.

    2016-01-01

    Full Text Available Description of the subject. This research note discusses the results of measurements of particulate matter concentrations inside a pig fattening facility. Objectives. The objectives of the present study were to investigate the correlations between the different size fractions of indoor particulate matter (PM inside a pig fattening facility and to investigate the evolution of particle size distribution (PSD through a fattening period and between two housing systems and two cleaning protocols. Method. Data from two consecutive fattening periods in a commercial pig barn were used. Results. Very high correlations were found between PM10 and PM2.5 indoor concentrations. Depending on the measuring instrument, high or low correlations were found between PM1 and PM10 or PM2.5 indoor concentrations. No differences in PSD could be found between the two housing systems or the two cleaning protocols. Conclusions. The results from the present study showed high correlations between the indoor concentrations of PM10 and PM2.5. In the present study, no differences in PSD were found.

  1. Bubble growth as a means to measure dissolved nitrogen concentration in aerated water

    Science.gov (United States)

    Ando, Keita; Yamashita, Tatsuya

    2017-11-01

    Controlling the amount of dissolved gases in water is important, for example, to food processing; it is essential to quantitatively evaluate dissolved gas concentration. The concentration of dissolved oxygen (DO) can be measured by commercial DO meters, but that of dissolved nitrogen (DN) cannot be obtained easily. Here, we propose a means to measure DN concentration based on Epstein-Plesset-type analysis of bubble growth under dissolved gas supersaturation. DO supersaturation in water is produced by oxygen microbubble aeration. The diffusion-driven growth of bubbles nucleated at glass surfaces in contact with the aerated water is first observed. The observed growth is then compared to the extended Epstein-Plesset theory that considers Fick's mass transfer of both DO and DN across bubble interfaces; in this comparison, the unknown DN concentration is treated as a fitting parameter. Comparisons between the experiment and the theory suggest, as expected, that DN can be effectively purged by oxygen microbubble aeration. This study was supported in part by the Mizuho Foundation for the Promotion of Science and by a MEXT Grant-in-Aid for the Program for Leading Graduate Schools.

  2. Measurement and analysis of the concentration and size distribution of aerosols in a copper mine

    International Nuclear Information System (INIS)

    Li Dehong; Zhuo Weihai; Huang Gang; Su Xu; Sun Quanfu

    2008-01-01

    Objective: To explore the general characteristics of the concentration and size distribution of aerosols in a mine. Methods: In different areas of a non-uranium mine, the particle number and mass concentration of aerosols were surveyed with a condensation particle counter and a personal aerosol monitor, respectively, and the size distribution of aerosols larger than 1 μm in size was estimated according to the size- selective measurements of mass concentrations. The size distribution of submicron aerosols was evaluated based on the method of screen diffusion battery (SOB), and the measurements were performed in both inside and outside of a control room. Results: The mass concentration of inhaled particles (PM10) was averaged to be 0.42 mg/m 3 in the whole mine, and it varied with different working areas and significantly affected with human activities. In the mine, particles lager than 1 μm in size widely distributed, while the particles less than 5 nm in size were seldom observed. Conclusions: The characteristics of aerosol significantly change with different working areas, human activities and Antilation condition in mine. The dose contribution from inhaled radioactive particles larger than 1 μm in size should be considered in mine. (authors)

  3. Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector

    International Nuclear Information System (INIS)

    Bastrikov, V.; Kruzhalov, A.; Zhukovsky, M.

    2006-01-01

    The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as α-particle detector and as absorber decreasing the energy of α-particles. The uncertainties of implanted 210 Pb measurements by two- and three-layer detectors are assessed in dependence on surface 210 Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from 210 Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached 218 Po and air exchange rate. It is demonstrated that with the use of additional information on surface to volume room ratio, air exchange rate and aerosol particles concentration the systematic bias of conversion coefficient between surface activity of 210 Po and average radon concentration can be decreased up to 30 %. (N.C.)

  4. Characterisation of an Ar-H2-O2 ICP by OES: Measurement of the atomic concentrations of H and O

    International Nuclear Information System (INIS)

    Altenberend J; Majchrzak M; Delannoy Y; Chichignoud G

    2011-01-01

    In order to characterize an inductively coupled plasma torch used in refining of metallurgical silicon, we have developed a spectroscopic method based on absolute emissivity measurements and Abel inversion. This method permitted to measure the concentrations of atomic hydrogen and atomic oxygen, which are among the reactive species involved in the purification process. Assuming LTE, the temperature profiles are deduced from the emissivity of the Argon lines. The concentration of atomic oxygen is deduced from the intensity ratio O/Ar. The hydrogen concentration measurement has to take into account the Stark broadening and the Doppler broadening of the hydrogen lines. The comparison between experimental and simulated line profiles permits to determine this concentration. The method has been tested on 2 kW and 30 kW inductively coupled plasma torches at atmospheric pressure. The results show that the concentrations of atomic oxygen and atomic hydrogen can be measured with an accuracy of 25%. The main disadvantage of this method is that, using emission, it does not permit to measure the concentration in the 'cold' zone of the plasma, i.e. at the edges.

  5. In situ measurements of hydrogen concentration and flux between 160 and 300 km in the thermosphere

    International Nuclear Information System (INIS)

    Breig, E.L.; Hanson, W.B.; Hoffman, J.H.; Kayser, D.C.

    1976-01-01

    Thermospheric concentrations of neutral atomic hydrogen near and below the F peak are directly related to H + , O + and atomic oxygen concentrations through the charge exchange equilibrium that is established between hydrogen and oxygen at these altitudes. This chemical relationship, together with in situ measurements of ionospheric and neutral atmospheric concentrations by instrumentation on board the Atmosphere Explorer C satellite, is utilized to investigate properties of neutral hydrogen at altitudes below 200 km where vertical diffusion strongly affects the hydrogen distribution. Data are discussed for a set of satellite orbits during quiet geomagnetic and solar conditions in February 1974; the resultant altitude variation of the derived hydrogen concentrations applies specifically to early afternoon at low 10 5 atoms/cm 3 is observed for these conditions at 300 km. At lower altitudes the concentration profiles are interpreted in terms of vertical hydrogen flow. The resultant daytime flux in the thermosphere is estimated to be (3.2 +- 1.0) x 10 8 atoms/cm 2 s. The present observations thus support theoretical estimates and model calculations of large hydrogen flow upward from the region below 100 km. They also support the concept of daytime thermospheric loss process of greater magnitude than the traditional evaporative escape mechanism

  6. Measurement of trimethylamine concentration and evaluation of pig meat natural quality by a spectrophotometric method

    Directory of Open Access Journals (Sweden)

    Mohammod Abdul HAMID,Xi WANG,Xiangdong DING,Chuduan WANG,Xingbo ZHAO

    2014-09-01

    Full Text Available Pig meat off-flavor is attributed to trimethylamine (TMA concentration, and it is considered as the precursor of the fishy off-flavor problems. In this study, TMA concentrations in pig meat were determined, and the interactions with breed and gender effects were discussed. In addition, the TMA threshold for meat off-flavor and pig meat natural quality was measured in relation to meat storage and movement, and the influential factors including the pig breed and storage time were discussed. The results indicated positive effects on the precursor of the fishy off-flavor and the TMA threshold. Native breeds were found to have lower TMA concentrations than European breeds (P<0.01, and females and castrated males had significantly lower TMA concentration than males (P<0.01, The threshold concentration of TMA when meat was classed as off-flavored was 25 μg·g-1, and this occurred after 35–38 h of storage. The natural qualities, such as appearance, flavor, color and overall acceptable scores declined significantly after 4 days in storage (P<0.01. It is concluded that pig meat off-flavor, breed and gender were essential factors affecting flavor for meat breeding programs, and storage time is important for pig meat natural quality.

  7. Measurement of fluorescent probes concentration ratio in the cerebrospinal fluid for early detection of Alzheimer's disease

    Science.gov (United States)

    Harbater, Osnat; Gannot, Israel

    2014-03-01

    The pathogenic process of Alzheimer's Disease (AD), characterized by amyloid plaques and neurofibrillary tangles in the brain, begins years before the clinical diagnosis. Here, we suggest a novel method which may detect AD up to nine years earlier than current exams, minimally invasive, with minimal risk, pain and side effects. The method is based on previous reports which relate the concentrations of biomarkers in the Cerebrospinal Fluid (CSF) (Aβ and Tau proteins) to the future development of AD in mild cognitive impairment patients. Our method, which uses fluorescence measurements of the relative concentrations of the CSF biomarkers, replaces the lumbar puncture process required for CSF drawing. The process uses a miniature needle coupled trough an optical fiber to a laser source and a detector. The laser radiation excites fluorescent probes which were prior injected and bond to the CSF biomarkers. Using the ratio between the fluorescence intensities emitted from the two biomarkers, which is correlated to their concentration ratio, the patient's risk of developing AD is estimated. A theoretical model was developed and validated using Monte Carlo simulations, demonstrating the relation between fluorescence emission and biomarker concentration. The method was tested using multi-layered tissue phantoms simulating the epidural fat, the CSF in the sub-arachnoid space and the bone. These phantoms were prepared with different scattering and absorption coefficients, thicknesses and fluorescence concentrations in order to simulate variations in human anatomy and in the needle location. The theoretical and in-vitro results are compared and the method's accuracy is discussed.

  8. Estimating the relation between groundwater and river water by measuring the concentration of Rn-222

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, Minoru; Morisawa, Shinsuke [Kyoto Univ. (Japan). Faculty of Engineering

    1997-02-01

    This study aimed to estimate the relationship between groundwater in shallow layer and river water by determining the concentrations of {sup 222}Rn and nitric nitrogen along with water temperature. The region around ca. 20 km along river A in a certain basin was chosen as a test area. The Rn concentration of groundwater was determined by Rn extracting with toluene and counting in liquid scintillation counter, whereas for river water, it was determined by activated charcoal passive collector method developed by the authors, by which the amount of Rn adsorbed on activated charcoal was estimated by Ge-solid state detector. In addition, water temperature and nitric nitrogen concentration were measured at various points in the test area. Thus, a distribution map of the three parameters was made on the basis of the data obtained in December, 1989. Since Rn concentration is generally higher in ground water than river water and the water temperature in December is higher in the former, it seems likely that the concentrations of Rn and nitric nitrogen would become higher in the area where ground water soaks into river water. Thus, the directions of ground water flow at the respective sites along river A were estimated from the data regarding the properties of ground water. (M.N.)

  9. Subaru Weak Lensing Measurements of Four Strong Lensing Clusters: Are Lensing Clusters Over-Concentrated?

    Energy Technology Data Exchange (ETDEWEB)

    Oguri, Masamune; Hennawi, Joseph F.; Gladders, Michael D.; Dahle, Haakon; Natarajan, Priyamvada; Dalal, Neal; Koester, Benjamin P.; Sharon, Keren; Bayliss, Matthew

    2009-01-29

    We derive radial mass profiles of four strong lensing selected clusters which show prominent giant arcs (Abell 1703, SDSS J1446+3032, SDSS J1531+3414, and SDSS J2111-0115), by combining detailed strong lens modeling with weak lensing shear measured from deep Subaru Suprime-cam images. Weak lensing signals are detected at high significance for all four clusters, whose redshifts range from z = 0.28 to 0.64. We demonstrate that adding strong lensing information with known arc redshifts significantly improves constraints on the mass density profile, compared to those obtained from weak lensing alone. While the mass profiles are well fitted by the universal form predicted in N-body simulations of the {Lambda}-dominated cold dark matter model, all four clusters appear to be slightly more centrally concentrated (the concentration parameters c{sub vir} {approx} 8) than theoretical predictions, even after accounting for the bias toward higher concentrations inherent in lensing selected samples. Our results are consistent with previous studies which similarly detected a concentration excess, and increases the total number of clusters studied with the combined strong and weak lensing technique to ten. Combining our sample with previous work, we find that clusters with larger Einstein radii are more anomalously concentrated. We also present a detailed model of the lensing cluster Abell 1703 with constraints from multiple image families, and find the dark matter inner density profile to be cuspy with the slope consistent with -1, in agreement with expectations.

  10. Concentration activities of natural radionuclides in three fish species in Brazilian coast and their contributions to the absorbed doses

    International Nuclear Information System (INIS)

    Pereira, Wagner de S.; Py Junior, Delcy de A.; Kelecom, Alphonse

    2009-01-01

    Activity concentrations of U-238, Ra-226, Pb-210, Th-232 e Ra-228 were analysed in three fish species at the Brasilian Coast. The fish 'Cubera snapper' (Lutjanus cyanopterus, Cuvier, 1828), in the region of Ceara and 'Whitemouth croaker' (Micropogonias furnieri, Desmarest, 1823) and 'Lebranche mullet' (Mugil liza, Valenciennes, 1836) in the region of Rio de Janeiro. These concentrations were transformed in absorbed dose rate using a dose conversion factor in unit of gray per year (μGy y -1 ), per becquerel per kilogram (Bq kg -1 ). Only the absorbed dose due to intake of radionuclides was examined, and the contributions due to radionuclides present in water and sediment were disregarded. The radionuclides were considered to be uniformly distributed in the fish body. The limit of the dose rate used, proposed by the Department of Energy of the USA, is equal to 3.65 10 03 mGy y -1 . The average dose rate due to the studied radionuclides is equal to 6.09 10 00 μGy y -1 , a value minor than 0.1% than the limits indicated by DOE, and quite similar to that found in the literature for 'benthic' fish. The most important radionuclides were the alpha emitters Ra-226 having 61 % of absorbed dose rate. U-238 and Th-232, each contributes with approximately 20 % of the absorbed dose rate. These three radionuclides are responsible for almost 100% of the dose rate received by the studied organisms. The beta emitters Ra-228 and Pb-210 account for approximately 1 % of the absorbed dose rate. (author)

  11. Measurement of cytoplasmic Ca2+ concentration in Saccharomyces cerevisiae induced by air cold plasma

    Science.gov (United States)

    Xiaoyu, DONG

    2018-03-01

    In this study, a novel approach to measure the absolute cytoplasmic Ca2+ concentration ([Ca2+]cyt) using the Ca2+ indicator fluo-3 AM was established. The parameters associated with the probe fluo-3 AM were optimized to accurately determine fluorescence intensity from the Ca2+-bound probe. Using three optimized parameters (final concentration of 6 mM probe, incubation time of 135 min, loading probe before plasma treatment), the maximum fluorescence intensity (F max = 527.8 a.u.) and the minimum fluorescence intensity (F min = 63.8 a.u.) were obtained in a saturated Ca2+ solution or a solution of lacking Ca2+. Correspondingly, the maximum [Ca2+]cyt induced by cold plasma was 1232.5 nM. Therefore, the Ca2+ indicator fluo-3 AM was successfully applied to measure the absolute [Ca2+]cyt in Saccharomyces cerevisiae stimulated by cold plasma at atmospheric air pressure.

  12. Field calibration of optical sensors for measuring suspended sediment concentration in the western Mediterranean

    Directory of Open Access Journals (Sweden)

    J. Guillén

    2000-12-01

    Full Text Available The water turbidity measured with optical methods (transmittance and backscattering is usually expressed as beam attenuation coefficient (BAC or formazin turbidity units (FTU. The transformation of these units to volumetric suspended sediment concentration (SSC units is not straightforward, and accurate calibrations are required in order to obtain valuable information on suspended sediment distributions and fluxes. In this paper, data from field calibrations between BAC, FTU and SSC are presented and best-fit calibration curves are shown. These calibrations represent an average from different marine environments of the western Mediterranean (from estuary to continental slope. However, the general curves can only be applied for descriptive or semi-quantitative purposes. Comparison of turbidity measurements using the same sensor with different calibration ranges shows the advantage of simultaneously combining two instruments calibrated in different ranges when significant changes in suspended sediment concentrations are expected.

  13. Size, velocity, and concentration in suspension measurements of spherical droplets and cylindrical jets.

    Science.gov (United States)

    Onofri, F; Bergougnoux, L; Firpo, J L; Misguich-Ripault, J

    1999-07-20

    The principle of an optical technique for simultaneous velocity, size, and concentration in suspension measurements of spherical droplets and cylindrical jets is proposed. This technique is based on phase Doppler anemometry working in the dual burst technique configuration. The particle size and velocity are deduced from the reflected signal phase and frequency, whereas the amplitude ratio between the refracted and the reflected signals is used for measuring the concentration of small scatterers inside the particles. Numerical simulations, based on geometrical optics and a Monte Carlo model, and an experimental validation test on cylindrical jets made of various suspensions, are used to validate the principle of the proposed technique. It is believed that this new technique could be useful in investigating processes in which liquid suspensions are sprayed for surface coating, drying, or combustion applications.

  14. Variation of molecular hydrogen tropospheric concentration over Southern Poland - results of the continuous chromatographic measurements.

    Science.gov (United States)

    Necki, J.; Chmura, L.

    2012-04-01

    Although hydrogen is one of the fundamental constituents of the earth's atmosphere its global balance is still poorly clarified. A few developed inventories diverging values for efficiency of sources and sinks of this gas. The European network for the hydrogen concentrations measurement is based on several unevenly spaced measurement points. While in 2009 MPI Jena has delivered accurate scale for hydrogen measurements and the techniques of analyses are well described, still large areas of Central Europe is uncovered by representative stations. The first measurement point, established under the EUROHYDROS EU program, on the territory of Poland was Kraków city. Different laboratory setups was tested there and compared to each other. The Kraków area has significant car traffic and its geographical location implies frequent temperature inversions in lower troposphere leading to the accumulation of trace gases in atmosphere of the city. Observations launched in 2007 revealed that the concentration of hydrogen fluctuates strongly within diurnal and seasonal timescales. Its average concentration is three times larger than this, observed at the other stations. The European "background" concentrations of hydrogen are not reflected in the Krakow record. An ideal place to carry out observation of the regional air composition for Central Europe is a research station located in the meteorological observatory at Kasprowy Wierch. Measurement point at the top of mountain peak with elevation of 2000m a.s.l. gives an access to the well mixed troposphere. The station delivers also the necessary facilities and logistics. Since year 1996 greenhouse gas measurement program has been operating at this point. The first measurements of atmospheric concentrations of hydrogen at Kasprowy Wierch were performed in year 2010, based on dedicated gas chromatograph using RGD detector installed at the station. Analysis of hydrogen content in the outside air is performed without any enrichment

  15. A Florescence Detection Module for Photodynamic Therapy Optimization by Measuring the Concentration of Photo sensitizer

    International Nuclear Information System (INIS)

    Serrano Navarro, Joel; Stolik Isakina, Suren; La Rosa Vazquez, Jose M. de; Valor Reed, Alma

    2016-01-01

    In the present work, a portable fluorescence detection system designed and built for dosimetry control applications in Photodynamic Therapy is presented. The system excites the used photo sensitizer drug with a modulated laser light source and subsequently measures the radiance of the emitted fluorescent light. Since the fluorescent radiance is directly related to the photosensitizers concentration, this measurement allows for real-time monitoring of the photo sensitizer concentration in the treated tissue. The system is thought to permit adjusting the therapeutic regime in order to optimize the expected therapy results. In the developed system, a synchronous detection technique is employed to recover the fluorescence signals embedded in noisy backgrounds and lit environments. A scanning probe with a 405 nm diode laser is used to excite the photo sensitizer, while a detection wavelength range from 590 nm to 700 nm has been implemented. (Author)

  16. Hydrogen peroxide and glucose concentration measurement using optical fiber grating sensors with corrodible plasmonic nanocoatings.

    Science.gov (United States)

    Zhang, Xuejun; Wu, Ze; Liu, Fu; Fu, Qiangqiang; Chen, Xiaoyong; Xu, Jian; Zhang, Zhaochuan; Huang, Yunyun; Tang, Yong; Guo, Tuan; Albert, Jacques

    2018-04-01

    We propose and demonstrate hydrogen peroxide (H 2 O 2 ) and glucose concentration measurements using a plasmonic optical fiber sensor. The sensor utilizes a tilted fiber Bragg grating (TFBG) written in standard single mode communication fiber. The fiber is over coated with an nm-scale film of silver that supports surface plasmon resonances (SPRs). Such a tilted grating SPR structure provides a high density of narrow spectral resonances (Q-factor about 10 5 ) that overlap with the broader absorption band of the surface plasmon waves in the silver film, thereby providing an accurate tool to measure small shifts of the plasmon resonance frequencies. The H 2 O 2 to be detected acts as an oxidant to etch the silver film, which has the effect of gradually decreasing the SPR attenuation. The etching rate of the silver film shows a clear relationship with the H 2 O 2 concentration so that monitoring the progressively increasing attenuation of a selected surface plasmon resonance over a few minutes enables us to measure the H 2 O 2 concentration with a limit of detection of 0.2 μM. Furthermore, the proposed method can be applied to the determination of glucose in human serum for a concentration range from 0 to 12 mM (within the physiological range of 3-8 mM) by monitoring the H 2 O 2 produced by an enzymatic oxidation process. The sensor does not require accurate temperature control because of the inherent temperature insensitivity of TFBG devices referenced to the core mode resonance. A gold mirror coated on the fiber allows the sensor to work in reflection, which will facilitate the integration of the sensor with a hypodermic needle for in vitro measurements. The present study shows that Ag-coated TFBG-SPR can be applied as a promising type of sensing probe for optical detection of H 2 O 2 and glucose detection in human serum.

  17. Measuring low radium activity concentration in water with RAD7 by means of evaporation

    International Nuclear Information System (INIS)

    Kappke, Jaqueline; Marussig, Camila G.T.; Paschuk, Sergei; Zambianchi Junior, Pedro; Correa, Janine N.; Perna, Allan Felipe Nunes; Martin, Aline

    2015-01-01

    Preliminary activity measurements of low radium concentration in mineral water by using RAD7 equipment showed high values of statistical errors. Therefore, the need to develop a new protocol for measuring and proofing the evaporation test for radium measurements in water is in place. This study evaluates the possibility of using RAD7 equipment to measure Ra-226 activity in equilibrium with Rn-222 present in water samples. The technique involves evaporation process so as to increase the Ra-226 concentration in the sample in a controlled manner and thus reduce statistical errors. Two samples were compared, 10 L sample of distilled water and a 7.75 L sample of known concentration (0.1 Bq/L). The evaporation was carried out starting with different initial volumes for both samples: 500 mL, 1000 mL, 2000 mL, 4000 mL and a 250 mL sample not subject to evaporation. All samples reached a final volume of approximately 250 mL. After evaporation, the samples were stored for 30 days until secular equilibrium was achieved between Ra-226 and Rn-222. The values obtained, by using RAD7 detector, for distilled water, as expected, are near zero averaging 0.021 ± 0.016 Bq/L. The average value found in the water of known concentration was 0.099 ± 0.011 Bq/L, also close to the expected 0.1 Bq/L. The conclusion is that the application of an evaporation process is efficient and the proposed methodology is a proven alternative to decrease the statistical errors. (author)

  18. Measuring gas concentration and wind intensity in a turbulent wind tunnel with a mobile robot

    OpenAIRE

    Martínez Lacasa, Daniel; Moreno Blanc, Javier; Tresánchez, Marcel; Clotet Bellmunt, Eduard; Jiménez-Soto, Juan M.; Magrans, Rudys; Pardo Martínez, Antonio; Marco Colás, Santiago; Palacín Roca, Jordi

    2016-01-01

    This paper presents themeasurement of gas concentration and wind intensity performed with amobile robot in a customturbulent wind tunnel designed for experimentation with customizable wind and gas leak sources.This paper presents the representation in different information layers of the measurements obtained in the turbulent wind tunnel under different controlled environmental conditions in order to describe the plume of the gas and wind intensities inside the experimentation chamber...

  19. Measurement of the concentration of plasmatic cortisol by competition to the binding protein

    International Nuclear Information System (INIS)

    Okada, H.; Tambascia, M.A.; Wajchenberg, B.L.; Pieroni, R.R.

    1977-01-01

    The concentration of plasmatic cortisol was measured by competition to the binding protein (transcortin), after extracting the samples with dicloromethane. It is a suitable method for clinical routine, 100μl of plasma being used in each analysis. The normal mean +- standard error mean in 8:00 a.m. fasting subjects was 13,62 +- 5,43 μl/100 ml of plasma [pt

  20. Hydrogen peroxide and glucose concentration measurement using optical fiber grating sensors with corrodible plasmonic nanocoatings

    Science.gov (United States)

    Zhang, Xuejun; Wu, Ze; Liu, Fu; Fu, Qiangqiang; Chen, Xiaoyong; Xu, Jian; Zhang, Zhaochuan; Huang, Yunyun; Tang, Yong; Guo, Tuan; Albert, Jacques

    2018-01-01

    We propose and demonstrate hydrogen peroxide (H2O2) and glucose concentration measurements using a plasmonic optical fiber sensor. The sensor utilizes a tilted fiber Bragg grating (TFBG) written in standard single mode communication fiber. The fiber is over coated with an nm-scale film of silver that supports surface plasmon resonances (SPRs). Such a tilted grating SPR structure provides a high density of narrow spectral resonances (Q-factor about 105) that overlap with the broader absorption band of the surface plasmon waves in the silver film, thereby providing an accurate tool to measure small shifts of the plasmon resonance frequencies. The H2O2 to be detected acts as an oxidant to etch the silver film, which has the effect of gradually decreasing the SPR attenuation. The etching rate of the silver film shows a clear relationship with the H2O2 concentration so that monitoring the progressively increasing attenuation of a selected surface plasmon resonance over a few minutes enables us to measure the H2O2 concentration with a limit of detection of 0.2 μM. Furthermore, the proposed method can be applied to the determination of glucose in human serum for a concentration range from 0 to 12 mM (within the physiological range of 3-8 mM) by monitoring the H2O2 produced by an enzymatic oxidation process. The sensor does not require accurate temperature control because of the inherent temperature insensitivity of TFBG devices referenced to the core mode resonance. A gold mirror coated on the fiber allows the sensor to work in reflection, which will facilitate the integration of the sensor with a hypodermic needle for in vitro measurements. The present study shows that Ag-coated TFBG-SPR can be applied as a promising type of sensing probe for optical detection of H2O2 and glucose detection in human serum. PMID:29675315

  1. Ultrasonic device for real-time sewage velocity and suspended particles concentration measurements.

    Science.gov (United States)

    Abda, F; Azbaid, A; Ensminger, D; Fischer, S; François, P; Schmitt, P; Pallarès, A

    2009-01-01

    In the frame of a technological research and innovation network in water and environment technologies (RITEAU, Réseau de Recherche et d'Innovation Technologique Eau et Environnement), our research group, in collaboration with industrial partners and other research institutions, has been in charge of the development of a suitable flowmeter: an ultrasonic device measuring simultaneously the water flow and the concentration of size classes of suspended particles. Working on the pulsed ultrasound principle, our multi-frequency device (1 to 14 MHz) allows flow velocity and water height measurement and estimation of suspended solids concentration. Velocity measurements rely on the coherent Doppler principle. A self developed frequency estimator, so called Spectral Identification method, was used and compared to the classical Pulse-Pair method. Several measurements campaigns on one wastewater collector of the French city of Strasbourg gave very satisfactory results and showed smaller standard deviation values for the Doppler frequency extracted by the Spectral Identification method. A specific algorithm was also developed for the water height measurements. It relies on the water surface acoustic impedance rupture and its peak localisation and behaviour in the collected backscattering data. This algorithm was positively tested on long time measurements on the same wastewater collector. A large part of the article is devoted to the measurements of the suspended solids concentrations. Our data analysis consists in the adaptation of the well described acoustic behaviour of sand to the behaviour of wastewater particles. Both acoustic attenuation and acoustic backscattering data over multiple frequencies are analyzed for the extrapolation of size classes and respective concentrations. Under dry weather conditions, the massic backscattering coefficient and the overall size distribution showed similar evolution whatever the measurement site was and were suggesting a global

  2. Estimation of natural potassium concentration in Romanian males by in vivo gamma-ray spectrometry measurements

    International Nuclear Information System (INIS)

    Mirela Angela Saizu

    2012-01-01

    At the Whole Body Monitoring Laboratory, from IFIN-HH, Bucharest, Romania, there were performed in vivo gamma-ray spectrometry measurements on 108 Romanian males in order to evaluate the mineral natural potassium content in human body, as total value and concentration. The measurements were performed with a shadow shield whole body counter, tilted chair geometry, based on a shielded NaI(Tl) scintillation detector of 12.5 cm (diameter) x 10 cm (height) crystal size. The results revealed a calculated value of the mean total body potassium (TBK) of 135.03 ± 2.94 g and a value of 1.9 ± 0.022 g of potassium/kg of body weight for the mean body potassium concentration, for the measured males. These values are similar with the values declared for the Reference Man, in ICRP23. Correlations between total body potassium, potassium concentration and age, weight and Body Build Index were investigated and peculiar conclusions were resulted. (author)

  3. Concentrations and flux measurements of volatile organic compounds (VOC) in boreal forest soil

    Science.gov (United States)

    Mäki, Mari; Aaltonen, Hermanni; Heinonsalo, Jussi; Hellén, Heidi; Pumpanen, Jukka; Bäck, Jaana

    2017-04-01

    Volatile organic compounds (VOC) impact soil processes as VOCs transmit signals between roots and rhizosphere (Ditengou et al., 2015), VOCs can regulate microbial activity (Asensio et al., 2012), and VOCs can also promote root growth (Hung et al., 2012). Belowground concentrations of VOCs have not been measured in situ and for this reason, knowledge of how different soil organisms such as roots, rhizosphere and decomposers contribute to VOC production is limited. The aim of this study was to determine and quantify VOC fluxes and concentrations of different horizons from boreal forest soil. The VOC concentrations and fluxes were measured from Scots pine (Pinus sylvestris) forest soil at the SMEAR II station in southern Finland from 21th of April to 2nd of December in 2016. VOC fluxes were measured using dynamic (flow-through) chambers from five soil collars placed on five different locations. VOC concentrations were also measured in each location from four different soil horizons with the measurement depth 1-107 cm. VOCs were collected from underground gas collectors into the Tenax-Carbopack-B adsorbent tubes using portable pumps ( 100 ml min-1). The VOC concentrations and fluxes of isoprene, 11 monoterpenes, 13 sesquiterpenes and different oxygenated VOCs were measured. Sample tubes were analyzed using thermal desorption-gas chromatograph-mass spectrometry (TD-GC-MS). Soil temperature and soil water content were continuously monitored for each soil horizon. Our preliminary results show that the primary source of VOCs is organic soil layer and the contribution of mineral soil to the VOC formation is minor. VOC fluxes and concentrations were dominated by monoterpenes such as α-pinene, camphene, β-pinene, and Δ3-carene. Monoterpene concentration is almost 10-fold in organic soil compared to the deeper soil layers. However, the highest VOC fluxes on the soil surface were measured in October, whereas the monoterpene concentrations in organic soil were highest in July

  4. Real-time measurements of suspended sediment concentration and particle size using five techniques

    Science.gov (United States)

    Felix, D.; Albayrak, I.; Abgottspon, A.; Boes, R. M.

    2016-11-01

    Fine sediments are important in the design and operation of hydropower plants (HPPs), in particular with respect to sediment management and hydro-abrasive erosion in hydraulic machines. Therefore, there is a need for reliable real-time measurements of suspended sediment mass concentration (SSC) and particle size distribution (PSD). The following instruments for SSC measurements were investigated in a field study during several years at the HPP Fieschertal in the Swiss Alps: (1) turbidimeters, (2) a Laser In-Situ Scattering and Trans- missometry instrument (LISST), (3) a Coriolis Flow and Density Meter (CFDM), (4) acoustic transducers, and (5) pressure sensors. LISST provided PSDs in addition to concentrations. Reference SSCs were obtained by gravimetrical analysis of automatically taken water samples. In contrast to widely used turbidimeters and the single-frequency acoustic method, SSCs obtained from LISST, the CFDM or the pressure sensors were less or not affected by particle size variations. The CFDM and the pressure sensors allowed measuring higher SSC than the optical or the acoustic techniques (without dilution). The CFDM and the pressure sensors were found to be suitable to measure SSC ≥ 2 g/l. In this paper, the measuring techniques, instruments, setup, methods for data treatment, and selected results are presented and discussed.

  5. Toward new instruments for measurement of low concentration hydrogen sulfide in small-quantity aqueous solutions

    International Nuclear Information System (INIS)

    Wu, Xiao Chu; Wu, Dong Qing; Zhang, W J; Sammynaiken, R; Yang, Wei; Wang, Rui

    2008-01-01

    Endogenously generated hydrogen sulfide (H 2 S) has been found to play some important physiological roles in the nervous and cardiovascular systems, such as a neuromodulator and a vasorelaxant. These roles are in contrast to our common perception that H 2 S is toxic. However, whether H 2 S plays a positive or negative role is dependent on the H 2 S concentration levels in mammals. This further puts a high demand on the accurate measurement of H 2 S in mammals with a further desire to be real time, continuous and in vivo. Existing methods for H 2 S measurement require a large number of tissue samples with complex procedures, and these methods are extremely invasive. The development of new in vivo and real-time methods for measuring H 2 S is, however, a great challenge. In the present study, we proposed and examined five potential H 2 S measurement methods: (1) atomic force microscopy with coating materials, (2) Raman spectroscopy on the H 2 S solutions, (3) gas chromatography/mass spectroscopy (with the static headspace technique) on the H 2 S solutions, (4) mass spectroscopy on unfunctionalized carbon nanotubes treated with the H 2 S solutions and (5) Raman spectroscopy on unfunctionalized carbon nanotubes treated with the H 2 S solutions. Our study concluded that method (5) is the most promising one for detecting low concentration H 2 S in small-quantity aqueous solutions in terms of measurement resolution and non-invasiveness, but the method is not very robust

  6. The estimation of heavy metal concentration in FBR reprocessing solvent streams by density measurement

    International Nuclear Information System (INIS)

    Brown, M.L.; Savage, D.J.

    1986-04-01

    The application of density measurement to heavy metal monitoring in the solvent phase is described, including practical experience gained during three fast reactor fuel reprocessing campaigns. An experimental algorithm relating heavy metal concentration and sample density was generated from laboratory-measured density data, for uranyl nitrate dissolved in nitric acid loaded tri-butyl phosphate in odourless kerosene. Differences in odourless kerosene batch densities are mathematically interpolated, and the algorithm can be used to estimate heavy metal concentrations from the density to within +1.5 g/l. An Anton Paar calculating digital densimeter with remote cell operation was used for all density measurements, but the algorithm will give similar accuracy with any density measuring device capable of a precision of better than 0.0005 g/cm 3 . For plant control purposes, the algorithm was simplified using a density referencing system, whereby the density of solvent not yet loaded with heavy metal is subtracted from the sample density. This simplified algorithm compares very favourably with empirical algorithms, derived from numerical analysis of density data and chemically measured uranium and plutonium data obtained during fuel reprocessing campaigns, particularly when differences in the acidity of the solvent are considered before and after loading with heavy metal. This simplified algorithm had been successfully used for plant control of heavy metal loaded solvent during four fast reactor fuel reprocessing campaigns. (author)

  7. A novel method of measuring the concentration of anaesthetic vapours using a dew-point hygrometer.

    Science.gov (United States)

    Wilkes, A R; Mapleson, W W; Mecklenburgh, J S

    1994-02-01

    The Antoine equation relates the saturated vapour pressure of a volatile substance, such as an anaesthetic agent, to the temperature. The measurement of the 'dew-point' of a dry gas mixture containing a volatile anaesthetic agent by a dew-point hygrometer permits the determination of the partial pressure of the anaesthetic agent. The accuracy of this technique is limited only by the accuracy of the Antoine coefficients and of the temperature measurement. Comparing measurements by the dew-point method with measurements by refractometry showed systematic discrepancies up to 0.2% and random discrepancies with SDS up to 0.07% concentration in the 1% to 5% range for three volatile anaesthetics. The systematic discrepancies may be due to errors in available data for the vapour pressures and/or the refractive indices of the anaesthetics.

  8. Water temperature and concentration measurements within the expanding blast wave of a high explosive

    International Nuclear Information System (INIS)

    Carney, J R; Lightstone, J M; Piecuch, S; Koch, J D

    2011-01-01

    We present an application of absorption spectroscopy to directly measure temperature and concentration histories of water vapor within the expansion of a high explosive detonation. While the approach of absorption spectroscopy is well established, the combination of a fast, near-infrared array, broadband light source, and rigid gauge allow the first application of time-resolved absorption measurements in an explosive environment. The instrument is demonstrated using pentaerythritol tetranitrate with a sampling rate of 20 kHz for 20 ms following detonation. Absorption by water vapor is measured between 1335 and 1380 nm. Water temperatures are determined by fitting experimental transmission spectra to a simulated database. Water mole fractions are deduced following the temperature assignment. The sources of uncertainty and their impact on the results are discussed. These measurements will aid the development of chemical-specific reaction models and the predictive capability in technical fields including combustion and detonation science

  9. Multi-species time-history measurements during high-temperature acetone and 2-butanone pyrolysis

    KAUST Repository

    Lam, Kingyiu; Ren, Wei; Pyun, Sunghyun; Farooq, Aamir; Davidson, David Frank; Hanson, Ronald Kenneth

    2013-01-01

    High-temperature acetone and 2-butanone pyrolysis studies were conducted behind reflected shock waves using five species time-history measurements (ketone, CO, CH3, CH4 and C2H4). Experimental conditions covered temperatures of 1100-1600 Kat 1.6 atm

  10. 76 FR 23935 - Atlantic Highly Migratory Species; Atlantic Shark Management Measures

    Science.gov (United States)

    2011-04-29

    .... 110120049-1144-01] RIN 0648-BA69 Atlantic Highly Migratory Species; Atlantic Shark Management Measures... retention, transshipping, landing, storing, or selling of hammerhead sharks in the family Sphyrnidae (except for Sphyrna tiburo) and oceanic whitetip sharks (Carcharhinus longimanus) caught in association with...

  11. 75 FR 57235 - Atlantic Highly Migratory Species; Atlantic Shark Management Measures

    Science.gov (United States)

    2010-09-20

    .... 100825390-0431-01] RIN 0648-BA17 Atlantic Highly Migratory Species; Atlantic Shark Management Measures... on potential adjustments to the regulations governing the U.S. Atlantic shark fishery to address several specific issues currently affecting management of the shark fishery and to identify specific goals...

  12. 77 FR 37647 - Atlantic Highly Migratory Species; Silky Shark Management Measures

    Science.gov (United States)

    2012-06-22

    .... 120416016-2151-01] RIN 0648-BB96 Atlantic Highly Migratory Species; Silky Shark Management Measures AGENCY..., transshipping, or landing of silky sharks (Carcharhinus falciformis) caught in association with ICCAT fisheries... sharks with bottom longline, gillnet, or handgear; nor would the rule affect recreational fishermen as...

  13. 76 FR 72383 - Atlantic Highly Migratory Species; Atlantic Shark Management Measures

    Science.gov (United States)

    2011-11-23

    ...-BA17 Atlantic Highly Migratory Species; Atlantic Shark Management Measures AGENCY: National Marine... plan (FMP) amendment that would consider catch shares for the Atlantic shark fisheries. The comment... potential catch shares programs in the Atlantic shark fisheries. Additionally, NMFS is extending the comment...

  14. Measurements of area and the (island) species-area relationship: new directions for an old pattern

    DEFF Research Database (Denmark)

    Triantis, K.A.; Nogues-Bravo, D.; Hortal, J.

    2008-01-01

    show that increasing the accuracy of the estimation of area has negligible impact on the fit and form of the species-area relationship, even though our analyses included some of the most topographically diverse island groups in the world. In addition, we show that the inclusion of general measurements...

  15. Measurements of ice nucleating particle concentrations at 242 K in the free troposphere

    Science.gov (United States)

    Lacher, L.; Lohmann, U.; Boose, Y.; Zipori, A.; Herrmann, E.; Bukowiecki, N.; Steinbacher, M.; Gute, E.; Kanji, Z. A.

    2017-12-01

    Clouds containing ice play an important role in the Earth's system, but some fundamental knowledge on their formation and further development is still missing. The phase change from vapor or liquid to ice in the atmosphere can occur heterogeneously in the presence of ice nucleating particles (INPs) at temperatures warmer, and supersaturations lower than required for homogeneous freezing. Only a small fraction of particles in an environment relevant for the occurrence of ice- and mixed-phase clouds are INPs, and their identification and quantification remains challenging. We measure INP concentrations with the ETH Horizontal Ice Nucleation Chamber (HINC) at the High Altitude Research Station Jungfraujoch (JFJ) during several field campaigns in different seasons and years. The measurements are performed at 242 K and above water saturation, representing ice- and mixed-phase clouds conditions. Due to its elevation of 3580 m a.s.l. the site encounters mostly free tropospheric conditions, and is influenced by boundary layer injections up to 80% of the time in summer. JFJ regularly encounters Saharan dust events and receives air masses of marine origin, which can both occur within the free troposphere. Our measurements show that INP concentrations in the free troposphere do not follow a seasonal cycle. They are remarkably constant, with concentrations from 0.5 - 8 L-1 (interquartile range), which compares well to measurements performed under the same conditions at another location within the free troposphere, the Izaña Atmospheric Research Station in Tenerife. At JFJ, correlations with parameters of physical properties of ambient particles, meteorology and air mass characteristics do not show a single best estimator to predict INP concentrations, emphasizing the complexity of ice nucleation in the free troposphere. Increases in INP concentrations of a temporary nature were observed in the free troposphere during Saharan dust events and marine air mass influence, which

  16. Measured soil water concentrations of cadmium and zinc in plant pots and estimated leaching outflows from contaminated soils

    DEFF Research Database (Denmark)

    Holm, P.E.; Christensen, T.H.

    1998-01-01

    Soil water concentrations of cadmium and zinc were measured in plant pots with 15 contaminated soils which differed in origin, texture, pH (5.1-7.8) and concentrations of cadmium (0.2-17 mg Cd kg(-1)) and zinc (36-1300 mg Zn kg(-1)). The soil waters contained total concentrations of 0.5 to 17 mu g...... to 0.1% per year of the total soil content of cadmium and zinc. The measured soil water concentrations of cadmium and zinc did not correlate linearly with the corresponding soil concentrations but correlated fairly well with concentrations measured in Ca(NO(3))(2) extracts of the soils and with soil...... water concentrations estimated from soil concentrations and pH. Such concentration estimates may be useful for estimating amounts of cadmium and zinc being leached from soils....

  17. Measuring Hair Cortisol Concentrations to Assess the Effect of Anthropogenic Impacts on Wild Chimpanzees (Pan troglodytes.

    Directory of Open Access Journals (Sweden)

    Esther H D Carlitz

    Full Text Available Non-human primates face major environmental changes due to increased human impacts all over the world. Although some species are able to survive in certain landscapes with anthropogenic impact, their long-term viability and fitness may be decreased due to chronic stress. Here we assessed long-term stress levels through cortisol analysis in chimpanzee hair obtained from sleeping nests in northwestern Uganda, in order to estimate welfare in the context of ecotourism, forest fragmentation with human-wildlife conflicts, and illegal logging with hunting activity (albeit not of primates, compared with a control without human contact or conflict. Concerning methodological issues, season [F(2,129 = 37.4, p < 0.0001, r2 = 0.18] and the age of nests [F(2,178 = 20.3, p < 0.0001, r2 = 0.11] significantly predicted hair cortisol concentrations (HCC. With regard to effects of anthropogenic impacts, our results neither showed elevation of HCC due to ecotourism, nor due to illegal logging compared to their control groups. We did, however, find significantly increased HCC in the fragment group compared to chimpanzees living in a nearby intact forest [F(1,88 = 5.0, p = 0.03, r2 = 0.20]. In conclusion, our results suggest that hair cortisol analysis is a powerful tool that can help understanding the impact of anthropogenic disturbances on chimpanzee well-being and could be applied to other great ape species.

  18. Measuring Hair Cortisol Concentrations to Assess the Effect of Anthropogenic Impacts on Wild Chimpanzees (Pan troglodytes).

    Science.gov (United States)

    Carlitz, Esther H D; Miller, Robert; Kirschbaum, Clemens; Gao, Wei; Hänni, Daniel C; van Schaik, Carel P

    2016-01-01

    Non-human primates face major environmental changes due to increased human impacts all over the world. Although some species are able to survive in certain landscapes with anthropogenic impact, their long-term viability and fitness may be decreased due to chronic stress. Here we assessed long-term stress levels through cortisol analysis in chimpanzee hair obtained from sleeping nests in northwestern Uganda, in order to estimate welfare in the context of ecotourism, forest fragmentation with human-wildlife conflicts, and illegal logging with hunting activity (albeit not of primates), compared with a control without human contact or conflict. Concerning methodological issues, season [F(2,129) = 37.4, p < 0.0001, r2 = 0.18] and the age of nests [F(2,178) = 20.3, p < 0.0001, r2 = 0.11] significantly predicted hair cortisol concentrations (HCC). With regard to effects of anthropogenic impacts, our results neither showed elevation of HCC due to ecotourism, nor due to illegal logging compared to their control groups. We did, however, find significantly increased HCC in the fragment group compared to chimpanzees living in a nearby intact forest [F(1,88) = 5.0, p = 0.03, r2 = 0.20]. In conclusion, our results suggest that hair cortisol analysis is a powerful tool that can help understanding the impact of anthropogenic disturbances on chimpanzee well-being and could be applied to other great ape species.

  19. Combined radiation-protective and radiation-sensitizing agents. IV. Measurement of intracellular protector concentrations

    International Nuclear Information System (INIS)

    Koch, C.J.; Stobbe, C.C.; Hettiaratchi, P.

    1989-01-01

    Radiosensitization of hypoxic V79 Chinese hamster cells by 0.5 mM misonidazole at approximately 0-4 degrees C is substantially enhanced by pretreating the cells overnight with 0.1 mM buthionine sulfoximine, which lowers the cellular glutathione content to 5% of control values (from 4 mM to approximately 0.2 mM). The enhanced sensitization is reversed by concentrations of exogenous cysteine that are much lower (0.02 mM) than the original glutathione content. Reduced Co-enzyme A affords reversal of the enhancing effect at concentrations of about 1 mM. Sodium ascorbate gives no protection at all even at concentrations of 2 mM. The intracellular concentration of the reducing agents was measured using a spin-through oil technique. There was no diffusion of Co-A (MW greater than 750) or ascorbate (excluded by charge) into the cells. In contrast, cysteine was rapidly concentrated by factors of 4-10, even at the low temperatures used. Extracellular ascorbate's inability to radioprotect argues against electron transfer across the cell membrane as a mechanism for radioprotection. This mechanism could have explained the ability of exogenous thiols to radioprotect in former studies using glutathione, and in the present studies using Co-A. The potential of cysteine to be concentrated by cells poses a problem in the interpretation of exogenous protection by non-diffusing thiols, since trace contamination by cysteine could lead to the actual protection observed. Cysteine could also be formed by exchange reactions of exogenous thiols with the disulfide of cysteine, present in all media formulations

  20. Changes of brain metabolite concentrations during maturation in different brain regions measured by chemical shift imaging.

    Science.gov (United States)

    Bültmann, Eva; Nägele, Thomas; Lanfermann, Heinrich; Klose, Uwe

    2017-01-01

    We examined the effect of maturation on the regional distribution of brain metabolite concentrations using multivoxel chemical shift imaging. From our pool of pediatric MRI examinations, we retrospectively selected patients showing a normal cerebral MRI scan or no pathologic signal abnormalities at the level of the two-dimensional 1H MRS-CSI sequence and an age-appropriate global neurological development, except for focal neurological deficits. Seventy-one patients (4.5 months-20 years) were identified. Using LC Model, spectra were evaluated from voxels in the white matter, caudate head, and corpus callosum. The concentration of total N-acetylaspartate increased in all regions during infancy and childhood except in the right caudate head where it remained constant. The concentration of total creatine decreased in the caudate nucleus and splenium and minimally in the frontal white matter and genu. It remained largely constant in the parietal white matter. The concentration of choline-containing compounds had the tendency to decrease in all regions except in the parietal white matter where it remained constant. The concentration of myoinositol decreased slightly in the splenium and right frontal white matter, remained constant on the left side and in the caudate nucleus, and rose slightly in the parietal white matter and genu. CSI determined metabolite concentrations in multiple cerebral regions during routine MRI. The obtained data will be helpful in future pediatric CSI measurements deciding whether the ratios of the main metabolites are within the range of normal values or have to be considered as probably pathologic.

  1. Changes of brain metabolite concentrations during maturation in different brain regions measured by chemical shift imaging

    International Nuclear Information System (INIS)

    Bueltmann, Eva; Lanfermann, Heinrich; Naegele, Thomas; Klose, Uwe

    2017-01-01

    We examined the effect of maturation on the regional distribution of brain metabolite concentrations using multivoxel chemical shift imaging. From our pool of pediatric MRI examinations, we retrospectively selected patients showing a normal cerebral MRI scan or no pathologic signal abnormalities at the level of the two-dimensional 1H MRS-CSI sequence and an age-appropriate global neurological development, except for focal neurological deficits. Seventy-one patients (4.5 months-20 years) were identified. Using LC Model, spectra were evaluated from voxels in the white matter, caudate head, and corpus callosum. The concentration of total N-acetylaspartate increased in all regions during infancy and childhood except in the right caudate head where it remained constant. The concentration of total creatine decreased in the caudate nucleus and splenium and minimally in the frontal white matter and genu. It remained largely constant in the parietal white matter. The concentration of choline-containing compounds had the tendency to decrease in all regions except in the parietal white matter where it remained constant. The concentration of myoinositol decreased slightly in the splenium and right frontal white matter, remained constant on the left side and in the caudate nucleus, and rose slightly in the parietal white matter and genu. CSI determined metabolite concentrations in multiple cerebral regions during routine MRI. The obtained data will be helpful in future pediatric CSI measurements deciding whether the ratios of the main metabolites are within the range of normal values or have to be considered as probably pathologic. (orig.)

  2. Changes of brain metabolite concentrations during maturation in different brain regions measured by chemical shift imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bueltmann, Eva; Lanfermann, Heinrich [Hannover Medical School, Institute of Diagnostic and Interventional Neuroradiology, Hannover (Germany); Naegele, Thomas [University of Tuebingen, Department of Diagnostic and Interventional Neuroradiology, Radiological University Hospital, Tuebingen (Germany); Klose, Uwe [University of Tuebingen, Section of Experimental MR of the CNS, Department of Neuroradiology, Radiological University Hospital, Tuebingen (Germany)

    2017-01-15

    We examined the effect of maturation on the regional distribution of brain metabolite concentrations using multivoxel chemical shift imaging. From our pool of pediatric MRI examinations, we retrospectively selected patients showing a normal cerebral MRI scan or no pathologic signal abnormalities at the level of the two-dimensional 1H MRS-CSI sequence and an age-appropriate global neurological development, except for focal neurological deficits. Seventy-one patients (4.5 months-20 years) were identified. Using LC Model, spectra were evaluated from voxels in the white matter, caudate head, and corpus callosum. The concentration of total N-acetylaspartate increased in all regions during infancy and childhood except in the right caudate head where it remained constant. The concentration of total creatine decreased in the caudate nucleus and splenium and minimally in the frontal white matter and genu. It remained largely constant in the parietal white matter. The concentration of choline-containing compounds had the tendency to decrease in all regions except in the parietal white matter where it remained constant. The concentration of myoinositol decreased slightly in the splenium and right frontal white matter, remained constant on the left side and in the caudate nucleus, and rose slightly in the parietal white matter and genu. CSI determined metabolite concentrations in multiple cerebral regions during routine MRI. The obtained data will be helpful in future pediatric CSI measurements deciding whether the ratios of the main metabolites are within the range of normal values or have to be considered as probably pathologic. (orig.)

  3. Heavy metal concentrations in redeveloping soil of mine spoil under plantations of certain native woody species in dry tropical environment, India

    Energy Technology Data Exchange (ETDEWEB)

    Singh, A.N.; Zeng, D.H.; Chen, F.S. [Chinese Academy of Science, Shenyang (China). Inst. of Applied Ecology

    2005-07-01

    Total concentration of heavy metals (Cd, Cr, Cu, Fe, Pb, Ni, Mn and Zn) was estimated in the redeveloping soil of mine spoil under 5-yr old plantations of four woody species namely: Albizia lebbeck, Albizia procera, Tectona grandis and Dendrocalamus strictus. The data recorded in the present study were compared with other unplanted coal mine spoil colliery, which was around to the study site and adjoining area of dry tropical forest. Among all the heavy metals, the maximum concentration was found for Fe and minimum for Cd. However, among all four species, total concentrations of these heavy metals were recorded maximally in the plantation plots of T. grandis except for Fe, while minimally in A. lebbeck except for Zn, whereas, the maximum concentration of Fe and Zn was in the plantation plots of D. strictus and A. procera. Statistical analysis revealed significant differences due to species for all the heavy metals except Cu. Among four species, A. lebbeck, A. procera and D. strictus showed more efficient for reducing heavy metal concentrations whereas T. grandis was not more effective to reduce heavy metal concentrations in redeveloping soil of mine spoil.

  4. Heavy metal concentrations in redeveloping soil of mine spoil under plantations of certain native woody species in dry tropical environment, India.

    Science.gov (United States)

    Singh, Anand N; Zeng, De-hui; Chen, Fu-sheng

    2005-01-01

    Total concentration of heavy metals (Cd, Cr, Cu, Fe, Pb, Ni, Mn and Zn) was estimated in the redeveloping soil of mine spoil under 5-yr old plantations of four woody species namely: Albizia lebbeck, Albizia procera, Tectona grandis and Dendrocalamus strictus. The data recorded in the present study were compared with other unplanted coal mine spoil colliery, which was around to the study site and adjoining area of dry tropical forest. Among all the heavy metals, the maximum concentration was found for Fe and minimum for Cd. However, among all four species, total concentrations of these heavy metals were recorded maximally in the plantation plots of T. grandis except for Fe, while minimally in A. lebbeck except for Zn, whereas, the maximum concentration of Fe and Zn was in the plantation plots of D. strictus and A. procera. Statistical analysis revealed significant differences due to species for all the heavy metals except Cu. Among four species, A. lebbeck, A. procera and D. strictus showed more efficient for reducing heavy metal concentrations whereas T. grandis was not more effective to reduce heavy metal concentrations in redeveloping soil of mine spoil.

  5. Water Use Patterns of Four Tropical Bamboo Species Assessed with Sap Flux Measurements.

    Science.gov (United States)

    Mei, Tingting; Fang, Dongming; Röll, Alexander; Niu, Furong; Hendrayanto; Hölscher, Dirk

    2015-01-01

    Bamboos are grasses (Poaceae) that are widespread in tropical and subtropical regions. We aimed at exploring water use patterns of four tropical bamboo species (Bambusa vulgaris, Dendrocalamus asper, Gigantochloa atroviolacea, and G. apus) with sap flux measurement techniques. Our approach included three experimental steps: (1) a pot experiment with a comparison of thermal dissipation probes (TDPs), the stem heat balance (SHB) method and gravimetric readings using potted B. vulgaris culms, (2) an in situ calibration of TDPs with the SHB method for the four bamboo species, and (3) field monitoring of sap flux of the four bamboo species along with three tropical tree species (Gmelina arborea, Shorea leprosula, and Hevea brasiliensis) during a dry and a wet period. In the pot experiment, it was confirmed that the SHB method is well suited for bamboos but that TDPs need to be calibrated. In situ, species-specific parameters for such calibration formulas were derived. During field monitoring we found that some bamboo species reached high maximum sap flux densities. Across bamboo species, maximal sap flux density increased with decreasing culm diameter. In the diurnal course, sap flux densities in bamboos peaked much earlier than radiation and vapor pressure deficit (VPD), and also much earlier than sap flux densities in trees. There was a pronounced hysteresis between sap flux density and VPD in bamboos, which was less pronounced in trees. Three of the four bamboo species showed reduced sap flux densities at high VPD values during the dry period, which was associated with a decrease in soil moisture content. Possible roles of internal water storage, root pressure and stomatal sensitivity are discussed.

  6. Atmospheric CO2 Concentration Measurements with Clouds from an Airborne Lidar

    Science.gov (United States)

    Mao, J.; Abshire, J. B.; Kawa, S. R.; Riris, H.; Allan, G. R.; Hasselbrack, W. E.; Numata, K.; Chen, J. R.; Sun, X.; DiGangi, J. P.; Choi, Y.

    2017-12-01

    Globally distributed atmospheric CO2 concentration measurements with high precision, low bias and full seasonal sampling are crucial to advance carbon cycle sciences. However, two thirds of the Earth's surface is typically covered by clouds, and passive remote sensing approaches from space are limited to cloud-free scenes. NASA Goddard is developing a pulsed, integrated-path differential absorption (IPDA) lidar approach to measure atmospheric column CO2 concentrations, XCO2, from space as a candidate for NASA's ASCENDS mission. Measurements of time-resolved laser backscatter profiles from the atmosphere also allow this technique to estimate XCO2 and range to cloud tops in addition to those to the ground with precise knowledge of the photon path-length. We demonstrate this measurement capability using airborne lidar measurements from summer 2017 ASCENDS airborne science campaign in Alaska. We show retrievals of XCO2 to ground and to a variety of cloud tops. We will also demonstrate how the partial column XCO2 to cloud tops and cloud slicing approach help resolving vertical and horizontal gradient of CO2 in cloudy conditions. The XCO2 retrievals from the lidar are validated against in situ measurements and compared to the Goddard Parameterized Chemistry Transport Model (PCTM) simulations. Adding this measurement capability to the future lidar mission for XCO2 will provide full global and seasonal data coverage and some information about vertical structure of CO2. This unique facility is expected to benefit atmospheric transport process studies, carbon data assimilation in models, and global and regional carbon flux estimation.

  7. Evaluation of uncertainties in femtoampere current measurement for the number concentration standard of aerosol nanoparticles

    International Nuclear Information System (INIS)

    Sakurai, Hiromu; Ehara, Kensei

    2011-01-01

    We evaluated uncertainties in current measurement by the electrometer at the current level on the order of femtoamperes. The electrometer was the one used in the Faraday-cup aerosol electrometer of the Japanese national standard for number concentration