WorldWideScience

Sample records for special diagnostic methods

  1. APPLICATION OF THE SPECTRUM ANALYSIS WITH USING BERG METHOD TO DEVELOPED SPECIAL SOFTWARE TOOLS FOR OPTICAL VIBRATION DIAGNOSTICS SYSTEM

    Directory of Open Access Journals (Sweden)

    E. O. Zaitsev

    2016-01-01

    Full Text Available The objective of this paper is development and experimental verification special software of spectral analysis. Spectral analysis use of controlled vibrations objects. Spectral analysis of vibration based on use maximum-entropy autoregressive method of spectral analysis by the Berg algorithm. For measured signals use preliminary analysis based on regression analysis. This analysis of the signal enables to eliminate uninformative parameters such as – the noise and the trend. For preliminary analysis developed special software tools. Non-contact measurement of mechanical vibrations parameters rotating diffusely-reflecting surfaces used in circumstances where the use of contact sensors difficult or impossible for a number of reasons, including lack of access to the object, the small size of the controlled area controlled portion has a high temperature or is affected by strong electromagnetic fields. For control use offered laser measuring system. This measuring system overcomes the shortcomings interference or Doppler optical measuring systems. Such as measure the large amplitude and inharmonious vibration. On the basis of the proposed methods developed special software tools for use measuring laser system. LabVIEW using for developed special software. Experimental research of the proposed method of vibration signals processing is checked in the analysis of the diagnostic information obtained by measuring the vibration system grinding diamond wheel cold solid tungsten-containing alloy TK8. A result of work special software tools was complex spectrum obtained «purified» from non-informative parameters. Spectrum of the signal corresponding to the vibration process observed object. 

  2. Special issue: diagnostics of atmospheric pressure microplasmas

    Science.gov (United States)

    Bruggeman, Peter; Czarnetzki, Uwe; Tachibana, Kunihide

    2013-11-01

    In recent decades, a strong revival of non-equilibrium atmospheric pressure plasma studies has developed in the form of microplasmas. Microplasmas have typical scales of 1 mm or less and offer a very exciting research direction in the field of plasma science and technology as the discharge physics can be considerably different due to high collisionality and the importance of plasma-surface interaction. These high-pressure small-scale plasmas have a diverse range of physical and chemical properties. This diversity coincides with various applications including light/UV sources [1], material processing [2], chemical analysis [3], material synthesis [4], electromagnetics [5], combustion [6] and even medicine [7]. At atmospheric pressure, large scale plasmas have the tendency to become unstable due to the high collision rates leading to enhanced heating and ionization compared to their low-pressure counterparts. As low-pressure plasmas typically operate in reactors with sizes of tens of centimetres, scaling up the pressure to atmospheric pressure the size of the plasma reduces to typical sizes below 1 mm. A natural approach of stabilizing atmospheric pressure plasmas is thus the use of microelectrode geometries. Traditionally microplasmas have been produced in confined geometries which allow one to stabilize dc excited discharges. This stabilization is intrinsically connected to the large surface-to-volume ratio which enhances heat transfer and losses of charged and excited species to the walls. Currently challenging boundaries are pushed by producing microcavity geometries with dimensions of the order of 1 µm [8]. The subject of this special issue, diagnostics of microplasmas, is motivated by the many challenges in microplasma diagnostics in view of the complex chemistry and strong spatial (and even temporal) gradients of species densities and plasma properties. Atmospheric pressure plasmas have a very long history dating back more than 100 years, with early work of

  3. Specialism in radiography - a contemporary history of diagnostic radiography

    International Nuclear Information System (INIS)

    Ferris, Christine

    2009-01-01

    Aim and method: Specialism is relative comparing the unusual to a norm. Origins of radiographers' perceptions of what is a specialism are identified. Semi-structured interviews were conducted with 21 practitioners and 10 leading voices whose combined practice span 1932-2001. Findings: Findings show that the exclusive nature of practice is influential on what is perceived as a specialism. Radiographers held career aspirations that included greater recognition, clinical involvement, autonomy and challenging work. Career aspirations were clinical rather than managerial and extended across modality boundaries. A key barrier to career progression was inequality of opportunity as local medical career requirements were dominant. Characteristics of specialism of diagnostic radiography are identified. Factors influencing the formation of specialism are also identified. Summary: Specialisation was dominant but not necessarily constructive to career progression or additional autonomy. Specialism relates to new areas of practice and is facilitated by service need, clear practice boundaries, visionary management, medical support, role development leading to increased autonomy and additional training and education.

  4. Specialism in radiography - a contemporary history of diagnostic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Ferris, Christine [Faculty of Health and Wellbeing, Sheffield Hallam University, Robert Winston Building, Sheffield, S10 2BP (United Kingdom)], E-mail: c.m.ferris@shu.ac.uk

    2009-12-15

    Aim and method: Specialism is relative comparing the unusual to a norm. Origins of radiographers' perceptions of what is a specialism are identified. Semi-structured interviews were conducted with 21 practitioners and 10 leading voices whose combined practice span 1932-2001. Findings: Findings show that the exclusive nature of practice is influential on what is perceived as a specialism. Radiographers held career aspirations that included greater recognition, clinical involvement, autonomy and challenging work. Career aspirations were clinical rather than managerial and extended across modality boundaries. A key barrier to career progression was inequality of opportunity as local medical career requirements were dominant. Characteristics of specialism of diagnostic radiography are identified. Factors influencing the formation of specialism are also identified. Summary: Specialisation was dominant but not necessarily constructive to career progression or additional autonomy. Specialism relates to new areas of practice and is facilitated by service need, clear practice boundaries, visionary management, medical support, role development leading to increased autonomy and additional training and education.

  5. Diagnostic method and reagent

    International Nuclear Information System (INIS)

    Edgington, T.S.; Plow, E.F.

    1979-01-01

    The discovery of an isomeric species of carcinoembryonic antigen and methods of isolation, identification and utilization as a radiolabelled species of the same as an aid in the diagnosis of adenocarcinomas of the gastrointestinal tract are disclosed. 13 claims

  6. Comparative evaluation of bivalent malaria rapid diagnostic tests versus traditional methods in field with special reference to heat stability testing in Central India.

    Directory of Open Access Journals (Sweden)

    Neeru Singh

    Full Text Available Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability.This study was undertaken in four forested districts of central India (July, 2011- March, 2012. All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9-98.8 and lowest sensitivity was 76% (95% CI; 71.7-79.6. For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9 and 20% (95% CI; 15.6-24.5 respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6-0.9.This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.

  7. Standing footprint diagnostic method

    Science.gov (United States)

    Fan, Y. F.; Fan, Y. B.; Li, Z. Y.; Newman, T.; Lv, C. S.; Fan, Y. Z.

    2013-10-01

    Center of pressure is commonly used to evaluate standing balance. Even though it is incomplete, no better evaluation method has been presented. We designed our experiment with three standing postures: standing with feet together, standing with feet shoulder width apart, and standing with feet slightly wider than shoulder width. Our platform-based pressure system collected the instantaneous plantar pressure (standing footprint). A physical quantity of instantaneous standing footprint principal axis was defined, and it was used to construct an index to evaluate standing balance. Comparison between results from our newly established index and those from the center of pressure index to evaluate the stability of different standing postures revealed that the standing footprint principal axis index could better respond to the standing posture change than the existing one. Analysis indicated that the insensitive response to the relative position between feet and to the standing posture change from the center of pressure could be better detected by the standing footprint principal axis index. This predicts a wide application of standing footprint principal axis index when evaluating standing balance.

  8. Leak detection by vibrational diagnostic methods

    International Nuclear Information System (INIS)

    Siklossy, P.

    1983-01-01

    The possibilities and methods of leak detection due to mechanical failures in nuclear power plants are reviewed on the basis of the literature. Great importance is attributed to vibrational diagnostic methods for their adventageous characteristics which enable them to become final leak detecting methods. The problems of noise analysis, e.g. leak detection by impact sound measurements, probe characteristics, gain problems, probe selection, off-line analysis and correlation functions, types of leak noises etc. are summarized. Leak detection based on noise analysis can be installed additionally to power plants. Its maintenance and testing is simple. On the other hand, it requires special training and measuring methods. (Sz.J.)

  9. Active and Passive Diagnostic Signatures of Special Nuclear Materials

    Energy Technology Data Exchange (ETDEWEB)

    Myers, William L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, Steven Charles [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-26

    An overview will be given discussing signatures associated with special nuclear materials acquired using both active and passive diagnostic techniques. Examples of how technology advancements have helped improve diagnostic capabilities to meet the challenges of today’s applications will be discussed.

  10. X-ray diagnostics in non-specialized conditions

    International Nuclear Information System (INIS)

    Vasil’yev, A Y; Lyubimenko, V A; Potrakhov, Y N; Potrakhov, N N; Bessonov, V B; Klonov, V V; Larionov, I A; Gryaznov, A Y; Zhamova, K K

    2017-01-01

    The results of research in the development of X-ray diagnostic equipment in non-specialized conditions are described. The design of the first domestic digital X-ray diagnostic complex for neonatology in portable design is presented. Examples of X-ray images obtained “at home” from a patient are given. (paper)

  11. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  12. Requirements for the special examination of isotope diagnostic specialists

    International Nuclear Information System (INIS)

    Csakany, Gyoergy

    1986-01-01

    Isotope diagnostic specialists are required to possess general paraclinical knowledge about nuclear physical principles, basic radiological measuring methods including up-to-date ones such as scintiscanning and tomography, as well as about radiopharmacology, radiation biology, health physics, radiation protection and organizational and economic aspects of the examinations. Clinical isotope diagnostic requirements comprise the proper selection among different radiological methods, the correct application of certain diagnostic procedures in practise, and the evaluation of the results in accordance with the symptoms on various fields of medical science. (V.N.)

  13. Tuberculosis diagnostic methods in buffaloes

    Directory of Open Access Journals (Sweden)

    Gabriela Capriogli Oliveira

    2015-07-01

    Full Text Available The low productivity of buffalo herds and condemnation of carcasses in slaughterhouses due to tuberculosis lesions have resulted in increasing economic losses because these animals cannot be treated and must be destroyed by sanitary slaughter. Tuberculosis is a widely distributed zoonosis that affects the beef supply chain of the Brazilian agribusiness economically and socially. Like cattle, buffaloes are sensitive to Mycobacterium bovis, which is the main causative agent of zoonotic tuberculosis. Tuberculosis in buffaloes has been reported in several countries, including Brazil. In order to control and eradicate this disease among cattle and buffaloes in Brazil, the Ministry of Agriculture, Livestock, and Supply created the National Program for the Control and Eradication of Brucellosis and Tuberculosis with the main objective of finding a significant number of disease-free herds throughout the national territory using reliable methods. This review summarizes the main data on the history of occurrence of M. bovis in Brazilian herds and the diagnostic methods for the disease in buffaloes. Little information is available on buffalo tuberculosis. Due to the increasing population of buffaloes and their economic importance, more studies investigating the occurrence and identification of tuberculosis in this species are clearly needed.

  14. Effective use of Monte Carlo methods for simulating photon transport with special reference to slab penetration problems in X-ray diagnostics

    International Nuclear Information System (INIS)

    Carlsson, G.A.

    1981-01-01

    The analysis of Monte Carlo methods has been made in connection with a particular problem concerning the transport of low energy photons (30-140 keV) through layers of water with thicknesses between 5 and 20 cm. While not claiming to be a complete exposition of available Monte Carlo techniques, the methodological analyses are not restricted to this particular problem. The report describes in a general manner a number of methods which can be used in order to obtain results of greater precision in a fixed computing time. (Auth.)

  15. A new method for analyzing diagnostic delay in gynecological cancer

    DEFF Research Database (Denmark)

    Vandborg, Mai Partridge; Edwards, Kasper; Kragtrup, Jakob

    2012-01-01

    AND METHODS: Six women with a diagnostic delay of 6 weeks or more before treatment of gynecological cancer at a specialized regional department (the Department of Gynecology and Obstetrics, Odense University Hospital, Denmark) were included in the study. Maps of existing processes were performed for each...

  16. A New Method for Analyzing Diagnostic Delay in Gynecological Cancer

    DEFF Research Database (Denmark)

    Vandborg, Mai Partridge; Edwards, Kasper; Kragstrup, Jakob

    2012-01-01

    AND METHODS: Six women with a diagnostic delay of 6 weeks or more before treatment of gynecological cancer at a specialized regional department (the Department of Gynecology and Obstetrics, Odense University Hospital, Denmark) were included in the study. Maps of existing processes were performed for each...

  17. Mismatch between diagnostic reports and special educational needs classification in a public educational system

    Directory of Open Access Journals (Sweden)

    Maria Cristina Triguero Veloz Teixeira

    Full Text Available ABSTRACT Objective To assess the diagnostic status, the sociodemographic and health profiles for students with special educational needs (SEN in a public educational system, and to map their use of educational/social services. Methods The sample comprised 1,202 SEN students from a total of 59,344 students. Results Only 792 students of the 1,202 had an established diagnosis. The most prevalent SEN condition was intellectual disability. There was a low percentage (29.4% of use of specialized educational services or support. It was found that, for some neurodevelopmental disorders, prevalence data suggest an under-reporting in the school system. Conclusion Results suggest that there is a mismatch between the diagnostic reports and the SEN condition legally recognized according to Brazilian law, in addition to the under-reporting and under specialized service use of students with disabilities.

  18. Artificial intelligence methods for diagnostic

    International Nuclear Information System (INIS)

    Dourgnon-Hanoune, A.; Porcheron, M.; Ricard, B.

    1996-01-01

    To assist in diagnosis of its nuclear power plants, the Research and Development Division of Electricite de France has been developing skills in Artificial Intelligence for about a decade. Different diagnostic expert systems have been designed. Among them, SILEX for control rods cabinet troubleshooting, DIVA for turbine generator diagnosis, DIAPO for reactor coolant pump diagnosis. This know how in expert knowledge modeling and acquisition is direct result of experience gained during developments and of a more general reflection on knowledge based system development. We have been able to reuse this results for other developments such as a guide for auxiliary rotating machines diagnosis. (authors)

  19. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology

    International Nuclear Information System (INIS)

    2010-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  20. Perspectives of special welding methods. 1

    International Nuclear Information System (INIS)

    Herden, G.; Buness, G.; Wiesner, P.

    1976-01-01

    Laser, electron, ion, and light beam welding as well as plasma arc welding are considered to be special fusion welding methods. The stage of development and possible future applications of these methods are described. (author)

  1. [Extrahepatic biliary atresia: diagnostic methods].

    Science.gov (United States)

    Cauduro, Sydney M

    2003-01-01

    To emphasize the importance of precocious diagnosis of extrahepatic biliary atresia and its direct relationship with the surgical re-establishment of the biliary flow before the second month of life. To discuss several complementary methods with the aim of selecting the ones that present better evidence, and avoiding delays in diagnosis and worse prognostic. Bibliographical researching regarding the period of 1985-2001, in Medline and MdConsult, using the following key words: neo-natal cholestasis; extrahepatic biliary atresia; neo-natal hepatitis. National and foreign articles were also elected based on the bibliography of consulted publications, and when necessary, for better understanding of the theme, opinions emitted in theses and textbooks were referred. The revision of the consulted bibliography led to the assumption that early diagnosis of EHBA and surgical treatment to reestablish the biliary flow up to 60 days of life are fundamental in order to achieve good results. Among several complementary methods of diagnosis, cholangiography by MR, US and the hepatic biopsy are the ones that provide the largest success indexes. The referring of patients bearers of EHBA to centers of references in Brazil, is still made tardily, probably due to lack of enlightenment of the doctors of primary attention, allied to bureaucratic and technological difficulties. The experience in England in relation to the "Yellow Alert" program, allowed that the number of children referred to surgical treatment before the 60 days of life increased significantly. Among the complementary methods, the MR cholangiography, ultrasonography and hepatic biopsy should be used, depending on the technological resources of the diagnosis units.

  2. Diagnostic methods for insect sting allergy.

    Science.gov (United States)

    Hamilton, Robert G

    2004-08-01

    This review overviews advances from mid-2002 to the present in the validation and performance methods used in the diagnosis of Hymenoptera venom-induced immediate-type hypersensitivity. The general diagnostic algorithm for insect sting allergy is initially discussed with an examination of the AAAAI's 2003 revised practice parameter guidelines. Changes as a result of a greater recognition of skin test negative systemic reactors include repeat analysis of all testing and acceptance of serology as a complementary diagnostic test to the skin test. Original data examining concordance of venom-specific IgE results produced by the second-generation Pharmacia CAP System with the Johns Hopkins University radioallergosorbent test are presented. Diagnostic performance of honeybee venom-specific IgE assays used in clinical laboratories in North America is discussed using data from the Diagnostic Allergy Proficiency Survey conducted by the College of American Pathologists. Validity of venom-specific IgE antibody in postmortem blood specimens is demonstrated. The utility of alternative in-vivo (provocation) and in-vitro (basophil-based) diagnostic testing methods is critiqued. This overview supports the following conclusions. Improved practice parameter guidelines include serology and skin test as complementary in supporting a positive clinical history during the diagnostic process. Data are provided which support the analytical performance of commercially available venom-specific IgE antibody serology-based assays. Intentional sting challenge in-vivo provocation, in-vitro basophil flow cytometry (CD63, CD203c) based assays, and in-vitro basophil histamine and sulfidoleukotriene release assays have their utility in the study of difficult diagnostic cases, but their use will remain as supplementary, secondary diagnostic tests.

  3. Health Technology Assessment for Molecular Diagnostics: Practices, Challenges, and Recommendations from the Medical Devices and Diagnostics Special Interest Group.

    Science.gov (United States)

    Garfield, Susan; Polisena, Julie; S Spinner, Daryl; Postulka, Anne; Y Lu, Christine; Tiwana, Simrandeep K; Faulkner, Eric; Poulios, Nick; Zah, Vladimir; Longacre, Michael

    2016-01-01

    Health technology assessments (HTAs) are increasingly used to inform coverage, access, and utilization of medical technologies including molecular diagnostics (MDx). Although MDx are used to screen patients and inform disease management and treatment decisions, there is no uniform approach to their evaluation by HTA organizations. The International Society for Pharmacoeconomics and Outcomes Research Devices and Diagnostics Special Interest Group reviewed diagnostic-specific HTA programs and identified elements representing common and best practices. MDx-specific HTA programs in Europe, Australia, and North America were characterized by methodology, evaluation framework, and impact. Published MDx HTAs were reviewed, and five representative case studies of test evaluations were developed: United Kingdom (National Institute for Health and Care Excellence's Diagnostics Assessment Programme, epidermal growth factor receptor tyrosine kinase mutation), United States (Palmetto's Molecular Diagnostic Services Program, OncotypeDx prostate cancer test), Germany (Institute for Quality and Efficiency in Healthcare, human papillomavirus testing), Australia (Medical Services Advisory Committee, anaplastic lymphoma kinase testing for non-small cell lung cancer), and Canada (Canadian Agency for Drugs and Technologies in Health, Rapid Response: Non-invasive Prenatal Testing). Overall, the few HTA programs that have MDx-specific methods do not provide clear parameters of acceptability related to clinical and analytic performance, clinical utility, and economic impact. The case studies highlight similarities and differences in evaluation approaches across HTAs in the performance metrics used (analytic and clinical validity, clinical utility), evidence requirements, and how value is measured. Not all HTAs are directly linked to reimbursement outcomes. To improve MDx HTAs, organizations should provide greater transparency, better communication and collaboration between industry and HTA

  4. ICT diagnostic method of beryllium welding quality

    International Nuclear Information System (INIS)

    Sun Lingxia; Wei Kentang; Ye Yunchang

    2002-01-01

    To avoid the interference of high density material for the quality assay of beryllium welding line, a slice by slice scanning method was proposed based upon the research results of the Industrial Computerized Tomography (ICT) diagnostics for weld penetration, weld width, off-centered deviation and weld defects of beryllium-ring welding seam with high density material inside

  5. Evaluation of laboratory diagnostic methods for cryptosporidiosis ...

    African Journals Online (AJOL)

    The conventional method of modified Ziehl-Neelsen (MZN) is very laborious, and stool ... Objective: This research was set to evaluate the diagnostic efficacy of ... 93.1% (MZN to ELISA) with ELISA techniques showing the highest sensitivity at ...

  6. Measuring methods for the TFR plasma diagnostics

    International Nuclear Information System (INIS)

    Etievant, C.

    1975-02-01

    The measuring methods in operation or still under development for the diagnostics of the TFR plasma parameters (ion and electron temperatures, electron density, current density are reviewed, the diagnostics of the electrical behavior of the discharge, the neutral gas densities, the impurities and the parameters of the plasma turbulence being also investigated. Actual works are principally devoted to: improving ion temperature measurements by the possible use of the Doppler effect or infra-red incoherent scattering; improving n(e) and T(e) measurement by Thomson scattering; measuring the poloidal field and current density; measuring impurities by X and UV spectroscopy and measuring instabilities and turbulence [fr

  7. DIAGNOSTIC METHODS IN BREAST CANCER DETECTION

    Directory of Open Access Journals (Sweden)

    Kristijana Hertl

    2018-02-01

    Full Text Available Background. In the world as well as in Slovenia, breast cancer is the most frequent female cancer. Due to its high incidence, it appears to be a serious health and economic problem. Content. Among other, tumour size at diagnosis, is an important prognostic factors of the course of the disease. The probability of axillary lymph node involvement as well as distant metastases is greater in larger tumours. This is the reason that encouraged the development of various diagnostic methods for early detection of small, clinically non-palpable breast tumours. Mammography, however, remains the »golden standard« of early breast cancer detection. It is the basic diagnostic method applied in all symptomatic women over 35 years of age and in asymptomatic women over 40 years of age. Ultrasonography (US, additional projections, magnetic resonance imaging (MRI and ductography are regarded as complementary diagnostic breast imaging techniques in addition to mammography. The detected changes in the breast can be further confirmed by US-, MR-guided or stereotactic biopsy. If necessary, surgical biopsy and the excision of a tissue sample, after wire or isotope localisation of the nonpalpable lesion, can be performed. Conclusions. Any of the above mentioned diagnostic methods has advantages as well as drawbacks and only detailed knowledge and understanding of each of them may assure the best option.

  8. On some methods of NPP functional diagnostics

    International Nuclear Information System (INIS)

    Babkin, N.A.

    1988-01-01

    Methods for NPP functional diagnosis, in which space and time dependences for controlled variable anomalous deviations change are used as characteristic features, are suggested. The methods are oriented for operative recognition of suddenly appearing defects and envelop quite a wide range of possible anomalous effects in an onject under diagnostics. Analysis of transients dynamic properties caused by a failure is realized according to the rules, which do not depend on the character of anomalous situation development

  9. The use of a special software for induction motor diagnostics in the diamond industry

    Directory of Open Access Journals (Sweden)

    Shevchuk Vladislav A.

    2017-01-01

    Full Text Available The field of induction motor application in the diamond industry has considerably increased due to the transition to the underground mining method. This article is devoted to the research the induction motor diagnostic technique in the diamond industry using special software. The practice shows that unreliability of induction motors causes some serious economic losses related to the expenses on premature maintenance and idle time. This article is devoted to the research of diagnostic technique of induction motors in the diamond industry using a special software. The article presents some data obtained in the course of the research conducted at an industrial site of the diamond company “ALROSA” in Mirny using the vibration-based diagnostics. Thus, based on the analysis of the findings some recommendations concerning the improvement of maintenance and servicing system have been given. The use of these recommendations allows assessing the operational reliability of induction motors in the diamond industry, minimizing the risk of sudden failures and reducing the maintenance and repair expenses.

  10. [CONTEMPORARY MOLECULAR-GENETIC METHODS USED FOR ETIOLOGIC DIAGNOSTICS OF SEPSIS].

    Science.gov (United States)

    Gavrilov, S N; Skachkova, T S; Shipulina, O Yu; Savochkina, Yu A; Shipulin, G A; Maleev, V V

    2016-01-01

    Etiologic diagnostics of sepsis is one of the most difficult problems of contemporary medicine due to a wide variety of sepsis causative agents, many of which are components of normal human microflora. Disadvantages of contemporary "golden standard" of microbiologic diagnostics of sepsis etiology by seeding of blood for sterility are duration of cultivation, limitation in detection of non-cultivable forms of microorganisms, significant effect of preliminary empiric antibiotics therapy on results of the analysis. Methods of molecular diagnostics that are being actively developed and integrated during the last decade are deprived of these disadvantages. Main contemporary methods of molecular-biological diagnostics are examined in the review, actualdata on their diagnostic characteristic are provided. Special attention is given to methods of PCR-diagnostics, including novel Russian developments. Methods of nucleic acid hybridization and proteomic analysis are examined in comparative aspect. Evaluation of application and perspectives of development of methods of molecular diagnostics of sepsis is given.

  11. Revolutionary diagnostic method using rotating atomic nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Frese, W.

    1986-01-23

    Nuclear tomography, a newcomer in medical diagnostics, has rapidly gained ground and recently achieved a decisive success: Electronic sectional images of the body which hitherto took measuring times of several minutes now can be obtained within only a few seconds. This jump in time has been earned by experts of the Goettingen Max Planck Institute for biophysical chemistry who puzzled out the significant modification of the method, which offers completely new insight to clinical diagnostics. One advantage is that nuclear magnetic resonance imaging - as the method also is called - allows dynamic processes to be made visible, and not only the movements of anatomic structures such as the heart, but indeed also physiological processes such as renal excretion. The other decisive improvement is that three-dimensional images of tissue and organs can be obtained. And on top of it all, nuclear magnetic resonance imaging does not invade the patient's body with harmful radiation.

  12. Revolutionary diagnostic method using rotating atomic nuclei

    International Nuclear Information System (INIS)

    Frese, W.

    1986-01-01

    Nuclear tomography, a newcomer in medical diagnostics, has rapidly gained ground and recently achieved a decisive success: Electronic sectional images of the body which hitherto took measuring times of several minutes now can be obtained within only a few seconds. This jump in time has been earned by experts of the Goettingen Max Planck Institute for biophysical chemistry who puzzled out the significant modification of the method, which offers completely new insight to clinical diagnostics. One advantage is that nuclear magnetic resonance imaging - as the method also is called - allows dynamic processes to be made visible, and not only the movements of anatomic structures such as the heart, but indeed also physiological processes such as renal excretion. The other decisive improvement is that three-dimensional images of tissue and organs can be obtained. And on top of it all, nuclear magnetic resonance imaging does not invade the patient's body with harmful radiation. (orig./MG) [de

  13. Diagnostic methods of fatty liver disease

    International Nuclear Information System (INIS)

    Kukuk, Guido Matthias; Sprinkart, Alois Martin; Traeber, Frank

    2017-01-01

    Fatty liver disease is defined as an abnormal accumulation of lipids into the cytoplasm of hepatocytes. Different kinds of fatty liver diseases are becoming the most important etiologies of end-stage liver disease in the western world. Because fatty liver is a theoretically reversible process, timely and accurate diagnosis is a prerequisite for potential therapeutic options. This work describes major diagnostic methods and discusses particular advantages and disadvantages of various techniques.

  14. Determination of HIV status of infants born to HIV-infected mothers: A review of the diagnostic methods with special focus on the applicability of p24 antigen testing in developing countries

    DEFF Research Database (Denmark)

    Wessman, Maria J; Theilgaard, Zahra Persson; Katzenstein, Terese L

    2012-01-01

    Abstract In 2009, 2.5 million children under the age of 15 y were living with human immunodeficiency virus/acquired immune deficiency syndrome (HIV/AIDS); 370,000 were diagnosed with HIV and 260,000 died due to AIDS. More than 90% of the children infected with HIV live in sub-Saharan Africa. Most...... children infected with HIV contract the infection in utero, during delivery, or via breast milk. This review outlines the current diagnostic methods to determine the HIV status of infants born to HIV-infected mothers. The HIV DNA and RNA polymerase chain reaction (PCR) tests are highly accurate...

  15. High speed manyframe optical methods for plasma diagnostics

    International Nuclear Information System (INIS)

    Erokhin, A.A.; Shikanov, A.S.; Sklizkov, G.V.; Zakharenkov, Yu.A.; Zorev, N.N.

    1979-01-01

    A complex of active optical plasma and strong ionized shock wave diagnostics is described. The complex consisted of a specially developed high speed manyframe systems of shadow, schlieren and interferometric photography. The comparison of results obtained by a simultaneous registration of investigated object by means of different optical methods allowed us to determine optimal employment range for the methods. The sensitivity, temporal and space resolution of each optical method under conditions of high probe radiation refraction are discussed. The application boundaries of these methods for ionized shock wave investigation were found to depend on the shock wave front width. The methods described were used for the study of laser-produced plasma phenomena, occuring in the experiments on powerful nine-channel laser installation ''Kalmar''. (author)

  16. Non-invasive diagnostic methods in dentistry

    Science.gov (United States)

    Todea, Carmen

    2016-03-01

    The paper, will present the most important non-invasive methods for diagnostic, in different fields of dentistry. Moreover, the laser-based methods will be emphasis. In orthodontics, 3D laser scanners are increasingly being used to establish database for normative population and cross-sectional growth changes but also to asses clinical outcomes in orthognatic surgical and non-surgical treatments. In prevention the main methods for diagnostic of demineralization and caries detection in early stages are represented by laser fluorescence - Quantitative Light Florescence (QLF); DiagnoDent-system-655nm; FOTI-Fiberoptic transillumination; DIFOTI-Digital Imaging Fiberoptic transillumination; and Optical Coherence Tomography (OCT). In odontology, Laser Doppler Flowmetry (LDF) is a noninvasive real time method used for determining the tooth vitality by monitoring the pulp microcirculation in traumatized teeth, fractured teeth, and teeth undergoing different conservative treatments. In periodontology, recently study shows the ability of LDF to evaluate the health of gingival tissue in periodontal tissue diseases but also after different periodontal treatments.

  17. Diagnostic methods of tubal factor in infertility

    International Nuclear Information System (INIS)

    Korzon, T.; Mielnik, J.; Gosciniak, W.

    1993-01-01

    The diagnostic methods of tubal factor in infertility have been presented. In details have been discussed PJ, PK HSG and pelviscopy. These examinations themselves constitute the basic ones in infertility. We turned our attention into technical details and possible mistakes which may occur at the time of performing them, these misinterpretations may lead to absolutely wrong conclusion and diagnosis. Authors have wide experience in performing the discussed examinations and this allows them to share their opinion. Over the years several thousand of PK and HSG examinations have been carried out and also 1000 laparoscopies. (author)

  18. DIAGNOSTICS OF MOTOR ABILITY AS A BASE OF CORRECTION PLANNING OF TRANSFORMATION PROCESSES IN SPECIAL POPULATIONS

    Directory of Open Access Journals (Sweden)

    Kosta Goranović

    2011-08-01

    Full Text Available In the research, at sample of 80 tested, employees in the special police force, as representatives of police population age from 20 to 25, diagnostics of motor potential in transitive period of annual macrostructure was done. The aim of the research was doing potential correction in planning and programming of transformation process in the next cycles of sports preparation on the base of diagnosed quantitative value of motor abilities. Besides analyses of achieved values, the difference was established between two leading teams in the space of measuring potential. The research results indicated to statistically important differences between two groups of tested people, as well as to unacceptable level of development in some abilities. The achieved results are, from aspect of training process’ control, the indicator to instructors’ team on the need of correction of transformation process’ content, with aim of improving bad segments. Diagnostics of motor abilities with measuring instruments in terrain conditions is one of methods, which can be in function of valorising transformation process of the special police force, taking into account specifics of their professional manifestation.

  19. Diagnostic methods of thermal dusty plasma flows

    International Nuclear Information System (INIS)

    Nefedov, A.P.

    1995-01-01

    The presence in the high-temperature flows of condensed disperse phase (CDP) particles may lead either to an increase of the electron number density n e if the particles assume a positive charge or to its decrease if the charge is negative. The existence of CDP also may effect on optical parameters of the thermal dusty plasma flows, on heat and radiative transfer in the plasma. The entire range of states, from a Debye plasma to a highly nonideal system of charged particles, is realized in a thermal dusty plasma under standard conditions T=2000-3000 K, n e =10 8 - 10 14 cm -3 . The advanced probe and optical diagnostic instruments are needed to study the optical and electrophysical properties of thermal dusty plasma flows. The diagnostic techniques must give the data about such parameters of gas and dispersed phase as temperatures of gas and particles, number densities of electrons, atoms and ions of alkali metals, sizes, velocities and concentrations of CDP particles. It should be noted that number density of alkali metal atoms and gas temperature may be measured by the well known full absorption and generalized reversal methods. This paper describes the probe and optical techniques for diagnostic of dusty plasma flows developed in High Energy Density Research Center of Russian Academy of Sciences. The Forward Angle Scattering Transmissometer (FAST) allows measurement of the average size (Sauter diameter), mass number density, and refractive index of particles in the 0.5-15.0 gm size range. The basis of the method is a dependence of the measured extinction of radiation upon an angular acceptance aperture of the photo detector. The FAST instrument allows one to determine the mass density and the Sauter diameter of a polydispersion of particles without a priori specification of the particle size distribution model and exact data about the article refractive index

  20. Diagnostic methods of thermal dusty plasma flows

    International Nuclear Information System (INIS)

    Nefedov, A.P.

    1995-01-01

    The presence in the high-temperature flows of condensed disperse phase (CDP) particles may lead either to an increase of the electron number density n e if the particles assume a positive charge or to its decrease if the charge is negative. The existence of CDP also may effect on optical parameters of the thermal dusty plasma flows, on heat and radiative transfer in the plasma. The entire range of states, from a Debye plasma to a highly nonideal system of charged particles, is realized in a thermal dusty plasma under standard conditions T=2000-3000 K, n e =10 8 -10 14 cm -3 . The advanced probe and optical diagnostic instruments are needed to study the optical and electrophysical properties of thermal dusty plasma flows. The diagnostic techniques must give the data about such parameters of gas and dispersed phase as temperatures of gas and particles, number densities of electrons, atoms and ions of alkali metals, sizes, velocities and concentrations of CDP particles. It should be noted that number density of alkali metal atoms and gas temperature may be measured by the well known full absorption and generalized reversal methods. This paper describes the probe and optical techniques for diagnostic of dusty plasma flows developed in High Energy Density Research Center of Russian Academy of Sciences. The Forward Angle Scattering Transmissometer (FAST) allows measurement of the average size (Sauter diameter), mass number density, and refractive index of particles in the 0.5-15.0 μm size range. The basis of the method is a dependence of the measured extinction of radiation upon an angular acceptance aperture of the photo detector. The FAST instrument allows one to determine the mass density and the Sauter diameter of a polydispersion of particles without a priori specification of the particle size distribution model and exact data about the particle refractive index

  1. Diagnostic efficacy of in vitro methods vs. skin testing in patients with inhalant allergies

    International Nuclear Information System (INIS)

    Corey, J.P.; Liudahl, J.J.; Young, S.A.; Rodman, S.M.

    1991-01-01

    The purpose of our study was to investigate the diagnostic efficacy of two selected methods of in vitro allergy testing. Specifically, the PRIST/modified RAST I125 isotope systems and the Quantizyme/modified EAST alkaline phosphatase method were compared. The time, expense, convenience, and diagnostic efficacy of the two procedures are discussed. Special attention is given to the practicality of each method for the practicing physician

  2. Diagnostic Methods for Feline Coronavirus: A Review

    Directory of Open Access Journals (Sweden)

    Saeed Sharif

    2010-01-01

    Full Text Available Feline coronaviruses (FCoVs are found throughout the world. Infection with FCoV can result in a diverse range of signs from clinically inapparent infections to a highly fatal disease called feline infectious peritonitis (FIP. FIP is one of the most serious viral diseases of cats. While there is neither an effective vaccine, nor a curative treatment for FIP, a diagnostic protocol for FCoV would greatly assist in the management and control of the virus. Clinical findings in FIP are non-specific and not helpful in making a differential diagnosis. Haematological and biochemical abnormalities in FIP cases are also non-specific. The currently available serological tests have low specificity and sensitivity for detection of active infection and cross-react with FCoV strains of low pathogenicity, the feline enteric coronaviruses (FECV. Reverse transcriptase polymerase chain reaction (RT-PCR has been used to detect FCoV and is rapid and sensitive, but results must be interpreted in the context of clinical findings. At present, a definitive diagnosis of FIP can be established only by histopathological examination of biopsies. This paper describes and compares diagnostic methods for FCoVs and includes a brief account of the virus biology, epidemiology, and pathogenesis.

  3. Specialized beam diagnostic measurements for an ADTT accelerator funnel

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, J.D.

    1995-10-01

    Los Alamos National Laboratory has proposed several CW-proton-beam facilities for accelerator-driven transmutation technologies (ADTT) with beam-current densities greater than 5 mA/mm{sup 2}. The primary beam-diagnostics-instrumentation requirement for these facilities is to provide sufficient beam information to understand and minimize beam-loss. To accomplish this task, the beam diagnostics instrumentation must measure beam parameters such as the projected centroids and profiles, total integrated current, and particle loss. Because of the high specific energy loss in materials at beam energies less than 20 MeV, interceptive measurements such as wire scanners or fluors cannot be used to determine beam profiles or centroids. Therefore, noninterceptive techniques must be used for on-line diagnosis of high-intensity CW beam at low energies. The beam funnel area of these proposed accelerator facilities provide a particular interesting beam measurement challenge. In this area of the accelerator, beam measurements must also sense how well the two funnel-input-beams are matched to each other in phase space. This paper will discuss some of the measurement requirements for these proposed accelerator facilities and the various noninterceptive techniques to measure dual-beam funnel operation.

  4. Transcranial Doppler sonography as diagnostic method

    Directory of Open Access Journals (Sweden)

    Jasminka Đelilović-Vranić

    2002-02-01

    Full Text Available Having in mind the fact that cerebrovascular disease (CVB takes today in medicine, in spite of diagnostic and therapeutic modernisation, the third place of mortality causes in the world (behind cordial and malignant diseases, but in front of depressions, and the second place of invalidity cause (right after trauma as well as the second place of dementia cause (after Alzheimer disease, it urges primary prophylaxis. Developing countries, but before all countries of East and Middle Europe, where is our country, are highly risked areas where CV disease has trend of incidence and total frequency increase. In the neighbouring Croatia today CV disease is at the first place of mortality causes. In the world today 5 million people annually suffer CV disease, in Europe about 700.000, but frequency of suffering on Balkan is about 5 prom. Age of CV disease effecting unfortunately moved towards young age, and today 49% of effected by CV disease are of 46 to 59 years of age. Early detection and treatment of risk factors (before hypertension, smoking, diabetes mellitus, hyperlipidaemia, stress and physical non-activities are the first aspect of CV disease prophylaxis. Together with this aspect of primary prophylaxis is early detection of complications of mentioned risk factors on the walls of blood vessels, before all changing in sense of arteriosclerosis, with consequence of disorder of cerebral haemodynamics. With that objective - verification of circulator and total haemodynamic disorders, there is obvious disclose of non-invasive diagnostic methods, and one of them is Transcranial Doppler Sonography(TCD. TCD is method comfortable for patient, reliable and rather precise, dynamic, and can be repeated several times, without side effects and in comparison with others rather cheap.

  5. The Diagnostic Value of ELISA Method for Pertussis in Children

    Directory of Open Access Journals (Sweden)

    O. P. Popova

    2016-01-01

    Full Text Available Because of low effectiveness of laboratory methods for diagnosing pertussis it is important to look for new ways of verification of this infection. The article presents the analysis of the diagnostic value of ELISA method, which involves the identification of antibodies of different isotypes (IgM, IgG, IgA to pertussis toxoid (PT and filamentous haemagglutinin (FHA. The study included 279 children: 114 were under 1 year of age, 165 — older than 1 year. The pertussis was confirmed in 74.3 ± 2.6% of patients by using ELISA method. A significant proportion of seronegative patients (46.1 ± 6.2 per cent was revealed in the group of patients under 1 year. The pattern of production of antibodies in unvaccinated children was different. It depended on the age of the children and timing of illness. A low proportion of diagnostically significant indicators of IgM-antibodies at 2—3 weeks of illness was typical for patients under 1 year of age (e.g. 6.7 ± 6.5% as compared to 20.0 ± 7.9% and 50.0 ± 15.3 — 1—3 and 4—6 years of age. The diagnosis of pertussis in children under 1 year of age was confirmed mainly by the detection of IgG, starting from the 4th week of the disease. In the examination of vaccinated children diagnostically significant levels of IgA and IgG were identified (even in the late stages of the disease. Thus, the results of the analysis show special significance of using ELISA method for the diagnosis of pertussis in vaccinated children.

  6. A specialized isotope mass spectrometer for noninvasive diagnostics of Helicobacter pylori infection in human beings

    Science.gov (United States)

    Blashenkov, N. M.; Sheshenya, E. S.; Solov'ev, S. M.; Sachenko, V. D.; Gall, L. N.; Zarutskii, I. V.; Gall, N. R.

    2013-05-01

    A specialized isotope mass spectrometer for noninvasive diagnostics of Helicobacter pylori infection in human beings based on the carbon-13 isotope breath test has been designed and constructed. Important stages of the work included (i) calculating a low-aberration mass analyzer, (ii) manufacturing and testing special gas inlet system, and (iii) creating a small-size collector of ions. The proposed instrument ensures 13C/12C isotopic ratio measurement to within 1.7‰ (pro mille) accuracy, which corresponds to requirements for a diagnostic tool. Preliminary medical testing showed that the mass spectrometer is applicable to practical diagnostics. The instrument is also capable of measuring isotopic ratios of other light elements, including N, O, B (for BF2+ ions), Ar, Cl, and S.

  7. Mismatch between diagnostic reports and special educational needs classification in a public educational system.

    Science.gov (United States)

    Teixeira, Maria Cristina Triguero Veloz; Brunoni, Décio; Carreiro, Luiz Renato Rodrigues; Braga, Ana Claudia; Silva, Naiara Adorna da; Paula, Cristiane Silvestre

    2017-04-01

    To assess the diagnostic status, the sociodemographic and health profiles for students with special educational needs (SEN) in a public educational system, and to map their use of educational/social services. The sample comprised 1,202 SEN students from a total of 59,344 students. Only 792 students of the 1,202 had an established diagnosis. The most prevalent SEN condition was intellectual disability. There was a low percentage (29.4%) of use of specialized educational services or support. It was found that, for some neurodevelopmental disorders, prevalence data suggest an under-reporting in the school system. Results suggest that there is a mismatch between the diagnostic reports and the SEN condition legally recognized according to Brazilian law, in addition to the under-reporting and under specialized service use of students with disabilities.

  8. Image processing methods and architectures in diagnostic pathology.

    Directory of Open Access Journals (Sweden)

    Oscar DĂŠniz

    2010-05-01

    Full Text Available Grid technology has enabled the clustering and the efficient and secure access to and interaction among a wide variety of geographically distributed resources such as: supercomputers, storage systems, data sources, instruments and special devices and services. Their main applications include large-scale computational and data intensive problems in science and engineering. General grid structures and methodologies for both software and hardware in image analysis for virtual tissue-based diagnosis has been considered in this paper. This methods are focus on the user level middleware. The article describes the distributed programming system developed by the authors for virtual slide analysis in diagnostic pathology. The system supports different image analysis operations commonly done in anatomical pathology and it takes into account secured aspects and specialized infrastructures with high level services designed to meet application requirements. Grids are likely to have a deep impact on health related applications, and therefore they seem to be suitable for tissue-based diagnosis too. The implemented system is a joint application that mixes both Web and Grid Service Architecture around a distributed architecture for image processing. It has shown to be a successful solution to analyze a big and heterogeneous group of histological images under architecture of massively parallel processors using message passing and non-shared memory.

  9. Application of noise analysis methods in nuclear reactor diagnostics

    International Nuclear Information System (INIS)

    Dach, K.

    1985-01-01

    By statistical evaluation of the fluctuation component of signals from selected detectors, noise diagnostics detects conditions of equipment which might later result in failure. The objective of early diagnostics is to detect the failed integrity of primary circuit components, failed detectors or anomalies of the thermohydraulic process. The commonest method of experimental data analysis is spectral analysis in the frequency range 0 to 50 Hz. Recently, expert diagnostic systems have been built based on artificial intelligence systems. Czechoslovakia participates in the experimental research of noise diagnostics in the context of the development of diagnostic assemblies for WWER-440 reactors. (M.D.)

  10. Analysis of Vibration Diagnostics Methods for Induction Motors

    Directory of Open Access Journals (Sweden)

    A. P. Kalinov

    2012-01-01

    Full Text Available The paper presents an analysis of existing vibration diagnostics methods. In order to evaluate an efficiency of method application the following criteria have been proposed: volume of input data required for establishing diagnosis, data content, software and hardware level, execution time for vibration diagnostics. According to the mentioned criteria a classification of vibration diagnostics methods for determination of their advantages and disadvantages, search for their development and improvement has been presented in paper. The paper contains a comparative estimation of methods in accordance with the proposed  criteria. According to this estimation the most efficient methods are a spectral analysis and spectral analysis of the vibration signal envelope.

  11. Estimation methods for special nuclear materials holdup

    International Nuclear Information System (INIS)

    Pillay, K.K.S.; Picard, R.R.

    1984-01-01

    The potential value of statistical models for the estimation of residual inventories of special nuclear materials was examined using holdup data from processing facilities and through controlled experiments. Although the measurement of hidden inventories of special nuclear materials in large facilities is a challenging task, reliable estimates of these inventories can be developed through a combination of good measurements and the use of statistical models. 7 references, 5 figures

  12. Punction methods of diagnostics and treatment of thyroid diseases

    Directory of Open Access Journals (Sweden)

    A.S. Tolstokorov

    2010-06-01

    Full Text Available The object of this research is to study the punction methods role under diagnostics and treatment of different thyroid diseases. The authors of this article present treatment methods of 121 patients with different thyroid diseases. The received results allow to draw a conclusion, that punction methods of diagnostics and treatment of thyroid disease can be used as independent methods of treatment and in a complex with other medication remedies

  13. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    Science.gov (United States)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  14. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment

    International Nuclear Information System (INIS)

    Costa, A.M.; Caldas, L.V.E.

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy responses of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities. (author)

  15. A special ionisation chamber for quality control of diagnostic and mammography X ray equipment.

    Science.gov (United States)

    Costa, A M; Caldas, L V E

    2003-01-01

    A quality control program for X ray equipment used for conventional radiography and mammography requires the constancy check of the beam qualities in terms of the half-value layers. In this work, a special double-faced parallel-plate ionisation chamber was developed with inner electrodes of different materials, in a tandem system. Its application will be in quality control programs of diagnostic and mammography X ray equipment for confirmation of half-value layers previously determined by the conventional method. Moreover, the chamber also may be utilised for measurements of air kerma values (and air kerma rates) in X radiation fields used for conventional radiography and mammography. The chamber was studied in relation to the characteristics of saturation, ion collection efficiency, polarity effects, leakage current, and short-term stability. The energy dependence in response of each of the two faces of the chamber was determined over the conventional radiography and mammography X ray ranges (unattenuated beams). The different energy response of the two faces of the chamber allowed the formation of a tandem system useful for the constancy check of beam qualities.

  16. Quantitative Methods for Molecular Diagnostic and Therapeutic Imaging

    OpenAIRE

    Li, Quanzheng

    2013-01-01

    This theme issue provides an overview on the basic quantitative methods, an in-depth discussion on the cutting-edge quantitative analysis approaches as well as their applications for both static and dynamic molecular diagnostic and therapeutic imaging.

  17. THE CURRENT METHODS FOR MOLECULAR DIAGNOSTICS OF FISH DISEASES (REVIEW

    Directory of Open Access Journals (Sweden)

    O. Zaloilo

    2016-06-01

    Full Text Available Purpose. The methods of molecular diagnostic (MMD gradually become widespread in modern fish farming. MMD contain a wide variety of specific approaches, each of which has distinct limits of their possible applications and is characterized by individual peculiarities in practical performance. In addition to high sensitivity and the possibility of rapid diagnostics, the main advantage of molecular methods is to determine the uncultivated infectious agents. DNA amplification allows identifying pathogenic microorganisms at very small quantities even in the minimum sample volume. Molecular methods of diagnostic enable the determination of infection in latent or acute phases. These methods allow showing the differences between pathogens with similar antigenic structures. The current literature data on this subject usually show a methodology in the narrow context of the tasks or practical results obtained through such approaches. Thus, a synthesis of existing information on the mechanisms of action and the limits of the typical problems of basic methods of molecular diagnostics are an urgent task of fish breeding. In particular, the following description will more effectively choose one or several approaches to identify pathogens in fish. Findings. This paper reviews the basic molecular methods that are used in the world's aquaculture for diagnosis of various diseases in commercial fish species. Originality. This work is a generalization of data on the principles and mechanisms for the implementation of diagnostics based on modern molecular techniques. For each of the mentioned approaches, the most promising areas of application were shown. The information is provided in the form of a comparative analysis of each methodology, indicating positive and negative practical aspects. Practical value. The current review of modern methods of molecular diagnostic in aquaculture is focused on practical application. Generalizing and analytical information can be

  18. Radiological methods for diagnostics of kidney cancer

    Directory of Open Access Journals (Sweden)

    Popkov V.M.

    2012-09-01

    Full Text Available It is stated that kidney cancer takes one of the leading places in the cancer incidence. Particular attention should be paid to renal cell carcinoma. By means of modern methods of volume visualization it is possible to diagnose small renal tumors, to prognose the process of tumor development and to save organs by surgical intervention.

  19. Diagnostic method of insulin metabolism disorders

    Energy Technology Data Exchange (ETDEWEB)

    Slavnov, V N; Ehpshtein, E V

    1975-08-25

    The invention is concerned with the medicine. For differential diagnosis in early stages of the disease blood samples are collected, according to the method suggested, 10 and 180 minutes after the indicator introduction, and the blood serum is radiometered prior to protein precipitation.

  20. Gastroesophageal reflux - correlation between diagnostic methods

    International Nuclear Information System (INIS)

    Cruz, Maria das Gracas de Almeida; Penas, Maria Exposito; Fonseca, Lea Mirian Barbosa; Lemme, Eponina Maria O.; Martinho, Maria Jose Ribeiro

    1999-01-01

    A group of 97 individuals with typical symptoms of gastroesophageal reflux disease (GERD) was submitted to gastroesophageal reflux scintigraphy (GES) and compared to the results obtained from endoscopy, histopathology and 24 hours pHmetry. Twenty-four healthy individuals were used as a control group and they have done only the GERS. The results obtained showed that: a) the difference int he reflux index (RI) for the control group and the sick individuals was statistically significant (p < 0.0001); b) the correlation between GERS and the other methods showed the following results: sensitivity, 84%; specificity, 95%; positive predictive value, 98%; negative predictive value, 67%; accuracy, 87%. We have concluded that the scintigraphic method should be used to confirm the diagnosis of GERD and also recommended as initial investiative procedure. (author)

  1. [The diagnostic methods applied in mycology].

    Science.gov (United States)

    Kurnatowska, Alicja; Kurnatowski, Piotr

    2008-01-01

    The systemic fungal invasions are recognized with increasing frequency and constitute a primary cause of morbidity and mortality, especially in immunocompromised patients. Early diagnosis improves prognosis, but remains a problem because there is lack of sensitive tests to aid in the diagnosis of systemic mycoses on the one hand, and on the other the patients only present unspecific signs and symptoms, thus delaying early diagnosis. The diagnosis depends upon a combination of clinical observation and laboratory investigation. The successful laboratory diagnosis of fungal infection depends in major part on the collection of appropriate clinical specimens for investigations and on the selection of appropriate microbiological test procedures. So these problems (collection of specimens, direct techniques, staining methods, cultures on different media and non-culture-based methods) are presented in article.

  2. Signal processing methods for MFE plasma diagnostics

    International Nuclear Information System (INIS)

    Candy, J.V.; Casper, T.; Kane, R.

    1985-02-01

    The application of various signal processing methods to extract energy storage information from plasma diamagnetism sensors occurring during physics experiments on the Tandom Mirror Experiment-Upgrade (TMX-U) is discussed. We show how these processing techniques can be used to decrease the uncertainty in the corresponding sensor measurements. The algorithms suggested are implemented using SIG, an interactive signal processing package developed at LLNL

  3. Serial rotatostereography - A new diagnostic method

    International Nuclear Information System (INIS)

    Ottomo, Michinori; Nakanishi, Takeshi.

    1986-01-01

    In the previous study using cine, a cine film stereoprojector showed the adjacent two frames of cine film simultaneously, such as frames 1 and 2, 2 and 3, 3 and 4, and so on, consecutively. Because some intracranial lesions require emergency surgery immediately after angiography, a real time display method of serial rotatostereography was necessary. In order to show the consecutive adjacent two frames of a video disc simultaneously, using the same method as with the cine stereoprojector, a video disc recorder (VDR) (VM-1000M) and two video memories (Image Σ) were required. This VDR has the ability of advancing, stopping, and reversing the display of memories. A control unit was manufactured in order to display these memories advancing and reversing continuously. As a result of this continuous semirotation stereo display, the anteroposterior projection was reversed, showing the posteroanterior view during ''reversing mode''. Thus a lead relay circuit was manufactured to prevent this phenomenon. Recording was done using a memory disc recorder (FOM 2200F), which has the ability of recording 10,000 frames per disc. Each frame can also be recorded on imaging film using O · X Multi Camera 400X. Finally, stereoscopic views of cerebral circulation, using a single injection of contrast media and rapid rotation of the gantry, were obtained using two cathode-ray tubes (CRTs) and a stereoviewer (Continuous Semi-rotation Classical Stereo Display Method). Stereoscopic views were also obtained using a single CRT, which displayed the images in a semirotating fashion similar to a oscillating fan head (Continuous Semi-rotation New Stereo Display Method). (J.P.N.)

  4. Diagnostic methods for dental caries used by private dental ...

    African Journals Online (AJOL)

    Objectives: This study aimed to investigate the preference profiles of various types of diagnostic tools and methods used by private dental practitioners in Ankara for detecting dental caries. Methods: Private dental practitioners, in five districts of Ankara, were provided with questionnaires comprising demographic ...

  5. Sensorless PV Array Diagnostic Method for Residential PV Systems

    DEFF Research Database (Denmark)

    Sera, Dezso; Spataru, Sergiu; Mathe, Laszlo

    2011-01-01

    This work proposes a temperature and irradiance sensorless diagnostic method suitable for small residential PV installations, focusing on detection of partial shadows. The method works by detection of failures in crystalline silicone PV arrays by concomitant monitoring of some of their key...

  6. Blower door method in radon diagnostics

    International Nuclear Information System (INIS)

    Fronka, A.; Moucka, L.

    2004-01-01

    The idea of the radon transfer factor is commonly presented as the ratio of the building indoor radon concentration to the subsoil radon concentration. Ventilation and the pressure field over the whole building envelope, which varies in a time over a very wide range even in the same building, poses a major problem. Therefore a new approach based on the controlled conditions determining the soil air infiltration was developed. Radon in soil gas infiltrates into the building indoor environment particularly through cracks and other leakages in the structure providing the building contact with its subsoil. The infiltration is driven by the air pressure difference on the two sides of the structure. The pressure difference is caused by the stack effect and its value ranges from 1-2 Pa in family houses to some tens of Pa in higher buildings. Unfortunately, the pressure difference is very unstable under normal conditions, being affected by a host of parameters such as the height of the building, distribution and geometry of leakages, outdoor-indoor temperature difference, etc. Wind direction and velocity of the wind plays a major role. In our research the blower door method was applied in combination with a monitoring of the indoor radon concentration. The indoor-outdoor pressure difference and the pressure difference at the two sides of the screen shutter of the blower door fan are also measured. The blower door ensures a constant, evaluable air exchange rate. The fan power is regulated to provide a stable pressure difference within the range of roughly 5-100 Pa. This approach provides very well defined conditions allowing us to apply a constant ventilation-constant radon supply model. In such circumstances the dynamical changes of radon concentrations are very fast, and therefore a unique continual radon monitor was applied. The radon supply rate is evaluated from the radon steady state of the time course of radon concentration. The dependence of the radon supply rate on

  7. Special methods used in neutron dosimetry

    International Nuclear Information System (INIS)

    Mas, P.

    1975-01-01

    The methods used in radiation reactor dosimetry which do not depend on fission reaction nor foil activation are reviewed. These other techniques are especially the following: the different types of self-powered detectors, with fast or slow response, their characteristics of noise and temperature effect, their practical uses: the damage detectors, considering the variations of their physical properties (resistivity, density, ...) and their use for characterizing the neutron spectra; the little loop with circulating fluids (air, nitrogen, helium, water) [fr

  8. Fault-tolerant and Diagnostic Methods for Navigation

    DEFF Research Database (Denmark)

    Blanke, Mogens

    2003-01-01

    to diagnose faults and autonomously provide valid navigation data, disregarding any faulty sensor data and use sensor fusion to obtain a best estimate for users. This paper discusses how diagnostic and fault-tolerant methods are applicable in marine systems. An example chosen is sensor fusion for navigation......Precise and reliable navigation is crucial, and for reasons of safety, essential navigation instruments are often duplicated. Hardware redundancy is mostly used to manually switch between instruments should faults occur. In contrast, diagnostic methods are available that can use analytic redundancy...

  9. Method for remote diagnostics of the internal structure of layered media

    International Nuclear Information System (INIS)

    Lychagov, V V; Kal'yanov, A L; Ryabukho, V P; Lyakin, D V

    2008-01-01

    The method of autocorrelation low coherence interferometry is proposed for diagnostics of inhomogeneities and the internal structure of layered technical and biological samples. In this method the low coherence optical field reflected from the layered sample is analysed by using a Michelson interferometer. Because the object is outside the interferometer, the distance between the interferometer and the object under study is not limited and thus the object can move during the measurements. Theoretical substantiation of the autocorrelation method for media with discrete and continuous optical structure modifications is presented. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

  10. Modern methods of early diagnostics of juvenile arthritis

    Directory of Open Access Journals (Sweden)

    Chernenkov Y.V.

    2013-06-01

    Full Text Available The problem of inflammatory diseases of joints is one of the most important issues in the pediatrics. Nowadays the significant attention in this sphere is paid to the search of new accurate criteria of diagnostics. It will help estimate the severity of disease, determine the prognosis, choose the method of treatment and monitoring and evaluate the efficacy of the therapy.

  11. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (French Edition)

    International Nuclear Information System (INIS)

    2012-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  12. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (Spanish Edition)

    International Nuclear Information System (INIS)

    2013-01-01

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  13. An assessment of diagnostic efficiency by Taguchi/DEA methods.

    Science.gov (United States)

    Taner, Mehmet Tolga; Sezen, Bulent

    2009-01-01

    The aim of this paper is to propose a new, objective and consistent method for the calculation of the diagnostic efficiency in medical applications. In this study, a hybrid method of Taguchi and DEA is proposed. This method reflects the diversity of inputs and outputs by incorporating the stepwise application of sensitivity, specificity, leveling threshold, and efficiency score. A hypothetical case study is given which involves eight readers of X-ray films in clinical radiology. The selected pairs of sensitivity and specificity yielded two efficient readers. After super efficiency analysis, Reader 6 is found to be the most efficient reader. The paper presents a new, objective and consistent method for the calculation of the diagnostic efficiency in medical applications.

  14. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  15. [Cognitive functions, their development and modern diagnostic methods].

    Science.gov (United States)

    Klasik, Adam; Janas-Kozik, Małgorzata; Krupka-Matuszczyk, Irena; Augustyniak, Ewa

    2006-01-01

    provided a theory. The psychometric approach concentrates on studying the differences in intelligence. The aim of this approach is to test intelligence by means of standardized tests (e.g. WISC-R, WAIS-R) used to show the individual differences among humans. Human cognitive functions determine individuals' adaptation capabilities and disturbances in this area indicate a number of psychopathological changes and are a symptom enabling to differentiate or diagnose one with a disorder. That is why the psychological assessment of cognitive functions is an important part of patients' diagnosis. Contemporary neuropsychological studies are to a great extent based computer tests. The use of computer methods has a number of measurement-related advantages. It allows for standardized testing environment, increasing therefore its reliability and standardizes the patient assessment process. Special attention should be paid to the neuropsychological tests included in the Vienna Test System (Cognitron, SIGNAL, RT, VIGIL, DAUF), which are used to assess the operational memory span, learning processes, reaction time, attention selective function, attention continuity as well as attention interference resistance. It also seems justified to present the CPT id test (Continuous Performance Test) as well as Free Recall. CPT is a diagnostic tool used to assess the attention selective function, attention continuity of attention, attention interference resistance as well as attention alertness. The Free Recall test is used in the memory processes diagnostics to assess patients' operational memory as well as the information organization degree in operational memory. The above mentioned neuropsychological tests are tools used in clinical assessment of cognitive function disorders.

  16. Study for the design method of multi-agent diagnostic system to improve diagnostic performance for similar abnormality

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents on industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning such as support vector machine is expected to detect the occurrence of abnormality in a plant early and correctly. There were reported that these diagnostic machines has high accuracy to diagnose the operating state of industrial plant under mono abnormality occurrence. But the each diagnostic machine on the multi-agent diagnostic system may misdiagnose similar abnormalities as a same abnormality if abnormalities to diagnose increases. That causes that a single diagnostic machine may show higher diagnostic performance than one of multi-agent diagnostic system because decision-making considering with misdiagnosis is difficult. Therefore, we study the design method for multi-agent diagnostic system to diagnose similar abnormality correctly. This method aimed to realize automatic generation of diagnostic system where the generation process and location of diagnostic machines are optimized to diagnose correctly the similar abnormalities which are evaluated from the similarity of process signals by statistical method. This paper explains our design method and reports the result evaluated our method applied to the process data of the fast-breeder reactor Monju

  17. Endoscopic and ultrasound diagnostics as contemporary method in diagnostics of dog stomach diseases

    Directory of Open Access Journals (Sweden)

    Krstić Vanja

    2005-01-01

    Full Text Available The visualization of pathological processes in the dog stomach determines a correct diagnosis or differential diagnosis, which presents the basic prerequisite for rational therapy. In addition to the conventional type of clinical examination which covers the taking of anamnestic data, observation of the patient and laboratory tests, there are also certain computerized diagnostic methods (magnetic resonance and scanner which are the most precise and most reliable in the verification of stomach diseases. However, the listed approaches are either insufficiently relevant in making the diagnosis or are too expensive and demanding for the everyday clinical practice. These are the reasons why veterinary medicine today increasingly resorts to the use of other forms of imaging diagnostics, and, as its representatives, the video endoscopic, ultrasound and X-ray examination of the digestive tract.

  18. Theory and design methods of special space orbits

    CERN Document Server

    Zhang, Yasheng; Zhou, Haijun

    2017-01-01

    This book focuses on the theory and design of special space orbits. Offering a systematic and detailed introduction to the hovering orbit, spiral cruising orbit, multi-target rendezvous orbit, initiative approaching orbit, responsive orbit and earth pole-sitter orbit, it also discusses the concept, theory, design methods and application of special space orbits, particularly the design and control method based on kinematics and astrodynamics. In addition the book presents the latest research and its application in space missions. It is intended for researchers, engineers and postgraduates, especially those working in the fields of orbit design and control, as well as space-mission planning and research.

  19. Calculation of radiation exposure in diagnostic radiology. Method and surveys

    International Nuclear Information System (INIS)

    Duvauferrier, R.; Ramee, A.; Ezzeldin, K.; Guibert, J.L.

    1984-01-01

    A computerized method for evaluating the radiation exposure of the main target organs during various diagnostic radiologic procedures is described. This technique was used for educational purposes: study of exposure variations according to the technical modalities of a given procedure, and study of exposure variations according to various technical protocols (IVU, EGD barium study, etc.). This method was also used for studying exposure of patients during hospitalization in the Rennes Regional Hospital Center (France) in 1982, according to departments (urology, neurology, etc.). This method and results of these three studies are discussed [fr

  20. DEVELOPING PSYCHOPEDAGOGICAL AND METHODICAL COMPETENCES IN SPECIAL / INCLUSIVE EDUCATION TEACHERS

    Directory of Open Access Journals (Sweden)

    Valentin Cosmin Blândul

    2017-08-01

    Full Text Available In a general sense, competence represents a higher finality which ensures the transfer of acquired theoretical knowledge to effective teaching practices. In the teaching profession, there are three types of competences: professional (they show the teacher's theoretical knowledge, psycho-pedagogical (they concern the teacher's ability to know their students and to establish interhuman relationships with them and methodical (concerns the teacher's ability to teach effectively the elements of the didactic content. Due to the particularities of special / inclusive education, teachers involved in this form of education should possess mainly psycho-pedagogical and methodical competences so that they can meet successfully the educational needs of students with disabilities. The aim of the research was to identify the psycho-pedagogical and methodical competences of special / inclusive education teachers, as well as ways to improve them using continued professional training activities. The sample consisted of 225 teachers, who work in various forms of special education in Bihor County, Romania. The instrument consisted of a questionnaire with 21 items. The research was conducted in April 2017. The results of the research showed that special education teachers are more empathetic and use a more diversified range of didactic strategies, while inclusive education teachers are concerned with continued professional training in the field of special education.

  1. Principles of dispensary observation of patients with Parkinson's disease in a specialized clinical diagnostic room

    Directory of Open Access Journals (Sweden)

    Krivonos О.V.

    2013-12-01

    Full Text Available Aim: to develop and implement of the order of the dispensary observation of Parkinson's disease patients. Material and methods, the dispensary observation of Parkinson's disease patients had been performed by neurologist and diagnostic room (CDR based on the outpatient department of health care institutions obeyed by FMBA of Russia in six Closed Administrative-Territorial Units: Seversk, Zarechniy, Ozersk, Lesnoy, Sarov and Zheleznogorsk. Neurologist examined of patients and put data to the Register's database. Register's database had 588 Parkinson's disease examined patients, 112 of them (19,1% had stage II of the disease by Hoehn and Yahr, 231 (39,3% patients — stage III by Hoehn and Yahr, 187 (31,8% patients — stage IV byHoehn and Yahr, 58 (9,9% patients — stage V by Hoehn and Yahr. The duration of the dispensary observation of Parkinson's disease patients was 4 years (2009-2012. Results. There are and implement the order of the observed and accounting of adult's group of Parkinson's disease patients were developed, who are registered in the clinical and diagnostic rooms, including the frequency of physician's visits, the list of diagnostic and treatment activities and efficiency endpoint of the dispensary observation. Conclusion. Implementation of the order of the dispensary observation according to the Register allowed to identify the main disabling PD's symptoms (depression, dementia, motor fluctuations and dyskinesia and timely correction of therapy.

  2. Diagnostic methods of fatty liver disease; Diagnostik der Fettleber

    Energy Technology Data Exchange (ETDEWEB)

    Kukuk, Guido Matthias; Sprinkart, Alois Martin; Traeber, Frank [Radiologische Universitaetsklinik Bonn (Germany). FE MRT

    2017-09-15

    Fatty liver disease is defined as an abnormal accumulation of lipids into the cytoplasm of hepatocytes. Different kinds of fatty liver diseases are becoming the most important etiologies of end-stage liver disease in the western world. Because fatty liver is a theoretically reversible process, timely and accurate diagnosis is a prerequisite for potential therapeutic options. This work describes major diagnostic methods and discusses particular advantages and disadvantages of various techniques.

  3. INTEGRATED APPLICATION OF OPTICAL DIAGNOSTIC METHODS IN ULCERATIVE COLITIS

    Directory of Open Access Journals (Sweden)

    E. V. Velikanov

    2013-01-01

    Full Text Available Abstract. Our results suggest that the combined use of optical coherent tomography (OCT and fluorescence diagnosis helps to refine the nature and boundaries of the pathological process in the tissue of the colon in ulcerative colitis. Studies have shown that an integrated optical diagnostics allows us to differentiate lesions respectively to histology and to decide on the need for biopsy and venue. This method is most appropriate in cases difficult for diagnosis. 

  4. Methodical approaches to solving special problems of testing. Seminar papers

    International Nuclear Information System (INIS)

    1996-01-01

    This Seminar volume introduces concepts and applications from different areas of application of ultrasonic testing and other non-destructive test methods in 18 lectures, in order to give an idea of new trends in development and stimuli for special solutions to problems. 3 articles were recorded separately for the ENERGY data bank. (orig./MM) [de

  5. Learning by Designing Interview Methods in Special Education

    DEFF Research Database (Denmark)

    Jönsson, Lise Høgh

    2017-01-01

    , and people with learning disabilities worked together to develop five new visual and digital methods for interviewing in special education. Thereby not only enhancing the students’ competences, knowledge and proficiency in innovation and research, but also proposing a new teaching paradigm for university...

  6. TRIZ method application for improving the special vehicles maintenance

    OpenAIRE

    Petrović Saša; Lozanović-Šajić Jasmina; Knežević Tijana; Pavlović Jovan; Ivanov Goran

    2014-01-01

    TRIZ methodology provides an opportunity for improving the classical engineering approach based on personal knowledge and experience. This paper presents the application of TRIZ methods for improving vehicle maintenance where special equipment is installed. A specific problem is the maintenance of the periscopes with heating system. Protective glass panels with heating system are rectangular glass elements. Their purpose is to perform mechanical protection ...

  7. A defect-driven diagnostic method for machine tool spindles.

    Science.gov (United States)

    Vogl, Gregory W; Donmez, M Alkan

    2015-01-01

    Simple vibration-based metrics are, in many cases, insufficient to diagnose machine tool spindle condition. These metrics couple defect-based motion with spindle dynamics; diagnostics should be defect-driven. A new method and spindle condition estimation device (SCED) were developed to acquire data and to separate system dynamics from defect geometry. Based on this method, a spindle condition metric relying only on defect geometry is proposed. Application of the SCED on various milling and turning spindles shows that the new approach is robust for diagnosing the machine tool spindle condition.

  8. THE METHODS OF LABORATORY DIAGNOSTICS OF UROGENITAL INFECTIONS ASSOCIATED WITH MYCOPLASMA HOMINIS AND UREAPLASMA SPP.

    Directory of Open Access Journals (Sweden)

    O. V. Zarucheynova

    2014-01-01

    Full Text Available Wide distribution of urogenital mycoplasmas in the population, the high frequency of carrier state and a long asymptomatic course of disease, the lack of specific clinical symptoms making the diagnosis impossible without using of special laboratory tests. The review focuses on indications for mycoplasma infection screening and for an appointmentof antibiotic therapy. The most commonly used laboratory diagnostic methods of urogenital infections, associated with Mycoplasma hominis and Ureaplasma spp., with their characteristics, advantages and disadvantages are described.

  9. Thyroid nodular disease: their usefulness of diagnostic methods

    International Nuclear Information System (INIS)

    Mendez Ayala, Irene Maria; Sanchez Luthard, Maria de los Angeles; Martins Schmitz; Gomez, Silvia

    2009-01-01

    The thyroid nodular disease is defined by the presence of nodules of thyroid of solid, liquid or mixed consistency, they are or non concrete. Solitary nodule thyroid, diffuse and multinodular goiter forms can be presented in. The thyroid nodule is a frequent clinical problem, the clinical prevalence in adult population is of 4%. Objective: to make a bibliographical revision to near the utility of the different methods available for the thyroid nodular pathology diagnosis and determining which of them turns out more specific to differentiate benignancy from malignancy in the found nodules. Materials and Methods: the bibliographical search was made in the data base Medline (Pubmed), in scientific magazines of the region and text books. Criteria of inclusion: bibliographical references pertaining to medical magazines and free full text with an antiquity nongreater to 8 years were included. Conclusion: the presence of thyroid nodules constitutes a reason for frequent consultation, the main diagnostic method at the moment is the fine needle aspiration cytology, due to its simple accomplishment, low cost, not requiring the hospitalization of the patient, and being fundamental in the decision making of the doctor. This diagnostic method is, in addition, the one that with greater certainty allows to differentiate benign from malignant nodules. (authors) [es

  10. External laryngeal injuries in children--comparison of diagnostic methods.

    Science.gov (United States)

    Zawadzka-Glos, L; Jakubowska, A; Frackiewicz, M; Brzewski, M

    2013-09-01

    The injuries of the larynx constitute around 1% of all injuries. The great majority of the injuries of the larynx happens during playing. The effects of these injuries may appear insignificant however, not always the direct clinical symptoms correlate with the degree of respiratory tract failure. The symptoms of laryngeal injuries depend on the extension and strength of the trauma and always relate to impair patency of respiratory tract. The aim of the study is to compare two diagnostic methods: laryngoscopy and ultrasonography in evaluation of laryngeal injuries in children. In the Department of Pediatric Otolaryngology, Medical University of Warsaw, in the period between 2004 and 2010 there were hospitalised 15 children with external injury of the larynx. From among 15 hospitalized children, 7 were qualified as not serious trauma and were treated preservatively and the other 8 as sever trauma. The mechanism of traumas was diverse. Dyspnea was a predominating symptom, the others included hoarsness, change in voice quality, even aphonia, pain while speaking and swallowing, cough and hemoptysis. Direct laryngoscopy is a standard in diagnostics of the injuries of the larynx. Ultrasonography of the larynx is recommended in every case of laryngeal injury as an additional non-invasive complementary diagnostic examination. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. method and container for production of diagnostic scanning agents

    International Nuclear Information System (INIS)

    Ruddock, C.F.

    1979-01-01

    The pertechnetate ion containing the technetium-99m isotope has limited applications in diagnostic scanning because it does not readily form complexes with materials which locate in specific parts of the body. Stannous salts have been widely used to reduce the pertechnetate to a form which readily complexes with materials. In the present invention, both a container and a more suitable metal reducing agent are discussed for transforming the technetium in pertechnetate for diagnostic scanning use. The vessel contains tin or a tin-containing alloy as a reducing agent for the pertechnetate and a complexant for the reduced technetium; all contents are sterile and dry. The present invention is advantageous over the stannous salts method since (1) problems of stannous salt instability during production, storage and after labelling are eliminated; (2) production procedures are simplified; (3) it is not essential to nitrogen purge vials before sterilisation; (4) it reduces toxicity; (5) the shelf life of diagnostic scanning kits may be dramatically improved; (6) the metal reducing agent may be sterilised by γ-irradiation without deteriorating; (7) the labelling technique can be performed over a wide pH range; and (8) the technique should be unaffected by technetium-99 in the technetium-99m. (U.K.)

  12. Diagnostic and therapeutic methods for occupational mercury poisoning

    International Nuclear Information System (INIS)

    Liu Zhanqi; Wang Xiuqin; Luo Futang

    2003-01-01

    A method of diagnosing and treating occupational mercury poisoning is reviewed in this paper. The treating measures for the chelating syndrome are also described. Based on his exposure history, urinary mercury, and clinical symptom, the employee who exposed occupationally to mercury can be diagnosed to a certain degree according to the related diagnostic standards. The chelating agent, such as meso-2, 3-dimercapto-succinicacid (DMSA), is used for mercury-lustrating treatment. By reducing the chelating agent dose and supplying necessary trace element, the side effect of chelating treatment is decreased. (authors)

  13. Diagnostic methods in sepsis: the need of speed

    Directory of Open Access Journals (Sweden)

    Fernando Rodrigues Coelho

    2012-08-01

    Full Text Available OBJECTIVE: Sepsis is a common condition encountered in hospital environments. There is no effective treatment for sepsis, and it remains an important cause of death at intensive care units. This study aimed to discuss some methods that are available in clinics, and tests that have been recently developed for the diagnosis of sepsis. METHODS: A systematic review was performed through the analysis of the following descriptors: sepsis, diagnostic methods, biological markers, and cytokines. RESULTS: The deleterious effects of sepsis are caused by an imbalance between the invasiveness of the pathogen and the ability of the host to mount an effective immune response. Consequently, the host's immune surveillance fails to eliminate the pathogen, allowing it to spread. Moreover, there is a pro-inflammatory mediator release, inappropriate activation of the coagulation and complement cascades, leading to dysfunction of multiple organs and systems. The difficulty achieve total recovery of the patient is explainable. There is an increased incidence of sepsis worldwide due to factors such as aging population, larger number of surgeries, and number of microorganisms resistant to existing antibiotics. CONCLUSION: The search for new diagnostic markers associated with increased risk of sepsis development and molecules that can be correlated to certain steps of sepsis is becoming necessary. This would allow for earlier diagnosis, facilitate patient prognosis characterization, and prediction of possible evolution of each case. All other markers are regrettably constrained to research units.

  14. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  15. Diagnostic agents containing albumin and methods for making same

    International Nuclear Information System (INIS)

    Saklad, E.L.; Layne, W.W.

    1981-01-01

    This patent specification outlines a method for providing a diagnostic agent for use in radiological testing, comprising the production of an admixture of a source of radionuclide ion (sup(99m)Tc), a reducing agent (source of stannous ions at a pH below 7) and a stabilized, defatted human albumin being sufficiently purified for an aqueous solution not to become cloudy for at least an hour at a pH of 4 or below. Other aspects of the patent provide for a method of producing a radiodiagnostic kit of the above components, packaged in a sealed sterile non-pyrogenic container, and also a method of concentrating sup(99m)Tc in vivo in a target mammalian tissue, by intravenous administration of a mixture of sup(99m)Tc, a reducing agent, and delipidized serum albumin. (U.K.)

  16. Lung cancer: Diagnostic procedures and therapeutic management, with special reference to radiotherapy

    International Nuclear Information System (INIS)

    Scarantino, C.W.

    1985-01-01

    This book on lung cancer provides a good overview of this very common cause of death in both men and women. The eight chapters in this book review a number of aspects of the disease including epidemiology, pathology, diagnostic workup, and treatment by radiation and chemotherapy. The two introductory chapters provide a summary of the epidemiology of this disease and an approach to each individual patient. Included are chapters on the many methods of treating lung cancer and the results of clinical trials as well as a brief discussion given to surgical treatment. A chapter on clinical research is directed primarily at ideas relating to chemotherapy. This brief book provides an overview of the many aspects involved in diagnosing and treating lung cancer

  17. A special purpose knowledge-based face localization method

    Science.gov (United States)

    Hassanat, Ahmad; Jassim, Sabah

    2008-04-01

    This paper is concerned with face localization for visual speech recognition (VSR) system. Face detection and localization have got a great deal of attention in the last few years, because it is an essential pre-processing step in many techniques that handle or deal with faces, (e.g. age, face, gender, race and visual speech recognition). We shall present an efficient method for localization human's faces in video images captured on mobile constrained devices, under a wide variation in lighting conditions. We use a multiphase method that may include all or some of the following steps starting with image pre-processing, followed by a special purpose edge detection, then an image refinement step. The output image will be passed through a discrete wavelet decomposition procedure, and the computed LL sub-band at a certain level will be transformed into a binary image that will be scanned by using a special template to select a number of possible candidate locations. Finally, we fuse the scores from the wavelet step with scores determined by color information for the candidate location and employ a form of fuzzy logic to distinguish face from non-face locations. We shall present results of large number of experiments to demonstrate that the proposed face localization method is efficient and achieve high level of accuracy that outperforms existing general-purpose face detection methods.

  18. Comparison of Machine Learning Methods for the Arterial Hypertension Diagnostics

    Directory of Open Access Journals (Sweden)

    Vladimir S. Kublanov

    2017-01-01

    Full Text Available The paper presents results of machine learning approach accuracy applied analysis of cardiac activity. The study evaluates the diagnostics possibilities of the arterial hypertension by means of the short-term heart rate variability signals. Two groups were studied: 30 relatively healthy volunteers and 40 patients suffering from the arterial hypertension of II-III degree. The following machine learning approaches were studied: linear and quadratic discriminant analysis, k-nearest neighbors, support vector machine with radial basis, decision trees, and naive Bayes classifier. Moreover, in the study, different methods of feature extraction are analyzed: statistical, spectral, wavelet, and multifractal. All in all, 53 features were investigated. Investigation results show that discriminant analysis achieves the highest classification accuracy. The suggested approach of noncorrelated feature set search achieved higher results than data set based on the principal components.

  19. Diagnostics and correction of disregulation states by physical methods

    OpenAIRE

    Gorsha, O. V.; Gorsha, V. I.

    2017-01-01

    Nicolaus Copernicus University, Toruń, Poland Ukrainian Research Institute for Medicine of Transport, Odesa, Ukraine Gorsha O. V., Gorsha V. I. Diagnostics and correction of disregulation states by physical methods Горша О. В., Горша В. И. Диагностика и коррекция физическими методами дизрегуляторных состояний Toruń, Odesa 2017 Nicolaus Copernicus University, To...

  20. Assessment of diagnostic methods for determining degradation of check valves

    International Nuclear Information System (INIS)

    Haynes, H.D.; Farmer, W.S.

    1992-01-01

    The Oak Ridge National Laboratory (ORNL) has carried out a comprehensive aging assessment of check valves in support of the Nuclear Plant Aging Research (NPAR) program. This paper provides a summary of the ORNL check valve aging assessment with emphasis on the identification, evaluation, and application of check valve monitoring methods and techniques. Several check valve monitoring methods are described and compared. These methods include: acoustic emission monitoring, ultrasonic inspection, magnetic flux signature analysis (MFSA), external magnetics. These diagnostic technologies were shown to be useful in determining check valve condition (e.g., disc position, disc motion, and seat leakage), although none of the methods was by itself, successful in monitoring all three condition indicators. The combination of acoustic emission with either ultrasonics or one of the magnetic technologies, however, yields a monitoring system that succeeds in providing the sensitivity to detect all major check valve operating conditions. Other areas covered in the paper include descriptions of relevant regulatory issues, utility group activities, and interactions ORNL has had with outside organizations for the purpose of disseminating research results

  1. Contributions of cytology examination and methods in lung cancer diagnostic

    International Nuclear Information System (INIS)

    Jerse, M.; Tercelj, M.

    2006-01-01

    Background. Lung cancer (LC) is still the leading cause of cancer death according to published data worldwide and confirmed also by the data obtained from the central Cancer Registry of Slovenia. Early detection of LC has an important impact on the long-term survival rate of the patients. In spite of a great advance in imaging technology for a better visualization and early detection of the neoplasms and a variety of screening tests, only cytopathology examination finally define the neoplastic lesion. Methods. To evaluate the contribution of cytology examination in the diagnosis of LC we studied the cytology diagnoses, comparing them with histology reports in patients, who underwent the diagnostic procedure under suspicion of the LC during last 2 years. Results. Of a total 772 patients, in 241 patients cancer was microscopically confirmed. The most frequent diagnoses were adenocarcinoma (36.9%), squamous cell carcinoma (26.6%), and small cell carcinoma (SCLC) (12.9%). There were 22% of neoplasms classified as non-small cell carcinomas (NSCLC). From the clinician point of view considering the therapy it is very important to distinguish NSCLC from SCLC. And in our study the cytology-histology correlation between these two major types of carcinoma was almost 100%. Based only on cytology, 68 (28.2%) patients received microscopic diagnosis of malignoma, and the specimens for this group of patients were obtained mostly from transbronchial or transthoracic fine needle aspiration biopsies. Conclusions. Cytology is of great diagnostic value, a reliable and relatively non-invasive method for patients. Cytology specimens should be taken in cases where it is not possible to obtain samples for histology. (author)

  2. Psychophysiological methods for the diagnostics of human functional states: New approaches and perspectives

    Directory of Open Access Journals (Sweden)

    Chernorizov A.M.

    2016-12-01

    Full Text Available L. S. Vygotsky in his famous methodological essay “The historical meaning of psychological crisis” (1928 emphasized the importance of studying any psychological process or state as a “whole” — that is, as characterized from the subjective and objective sides at the same time. This position is fully relevant for studying the human functional states (FSes. Today the objective psychophysiological diagnostics of human FSes in activities associated with a high risk of technological disasters (in nuclear-power plants, transportation, the chemical industry are extremely relevant and socially important. This article reviews some new psychophysiological methods of FS assessment that are being developed in Russia and abroad and discusses different aspects of developing integral psychophysiological FS assessment. The emphasis is on distant methods of FS diagnostics: the bioradiolocation method, laser Doppler vibrometry, eye tracking, audio and video recordings, infrared thermography. The possibilities and limitations of the most popular emotion atlases — the Facial Affect Scoring Technique (FAST and the Facial Action Coding System (FACS — in developing distant visual-range and infrared-range systems for automated classification of facial expressions are analyzed. A special section of the article concentrates on the problem of constructing an integral psychophysiological FS index. Mathematical algorithms that provide a partition of FS indicators into different FS types are based on various methods of machine learning. We propose the vector approach for construction of complex estimations of the human FSes.

  3. TRIZ method application for improving the special vehicles maintenance

    Directory of Open Access Journals (Sweden)

    Petrović Saša

    2014-01-01

    Full Text Available TRIZ methodology provides an opportunity for improving the classical engineering approach based on personal knowledge and experience. This paper presents the application of TRIZ methods for improving vehicle maintenance where special equipment is installed. A specific problem is the maintenance of the periscopes with heating system. Protective glass panels with heating system are rectangular glass elements. Their purpose is to perform mechanical protection of built-in prisms and provide heating of the prisms. Aging and long-term use leads to failure of these elements. The practice requires solutions in order to extend the lifetime of the system. New solution is evaluated by simulation and experiment.

  4. Diagnostic methods to assess inspiratory and expiratory muscle strength

    Directory of Open Access Journals (Sweden)

    Pedro Caruso

    2015-04-01

    Full Text Available Impairment of (inspiratory and expiratory respiratory muscles is a common clinical finding, not only in patients with neuromuscular disease but also in patients with primary disease of the lung parenchyma or airways. Although such impairment is common, its recognition is usually delayed because its signs and symptoms are nonspecific and late. This delayed recognition, or even the lack thereof, occurs because the diagnostic tests used in the assessment of respiratory muscle strength are not widely known and available. There are various methods of assessing respiratory muscle strength during the inspiratory and expiratory phases. These methods are divided into two categories: volitional tests (which require patient understanding and cooperation; and non-volitional tests. Volitional tests, such as those that measure maximal inspiratory and expiratory pressures, are the most commonly used because they are readily available. Non-volitional tests depend on magnetic stimulation of the phrenic nerve accompanied by the measurement of inspiratory mouth pressure, inspiratory esophageal pressure, or inspiratory transdiaphragmatic pressure. Another method that has come to be widely used is ultrasound imaging of the diaphragm. We believe that pulmonologists involved in the care of patients with respiratory diseases should be familiar with the tests used in order to assess respiratory muscle function.Therefore, the aim of the present article is to describe the advantages, disadvantages, procedures, and clinical applicability of the main tests used in the assessment of respiratory muscle strength.

  5. Diagnostic methods in finding out the causes of infertility, results of HSG examination and laparoscopy in infertile women examined at the Gynecological Ward of the City Hospital

    International Nuclear Information System (INIS)

    Kwasniewski, S.; Kukulski, P.; Szymanski, J.; Kwasniewska, A.

    1993-01-01

    The paper presents diagnostic methods and the results of hysterosalpingography (HSG) and laparoscopy examination, with special attention being drawn to the usefulness of these methods in finding out the causes of infertility. 51 patients with primary and second infertility were examined. HSG and laparoscopy make it possible to diagnose correctly the cause of infertility. They also enable adequate and early classification of patients for further diagnosis and treatment at highly specialized centers dealing with the problems of infertility. (author)

  6. Multi-method automated diagnostics of rotating machines

    Science.gov (United States)

    Kostyukov, A. V.; Boychenko, S. N.; Shchelkanov, A. V.; Burda, E. A.

    2017-08-01

    The automated machinery diagnostics and monitoring systems utilized within the petrochemical plants are an integral part of the measures taken to ensure safety and, as a consequence, the efficiency of these industrial facilities. Such systems are often limited in their functionality due to the specifics of the diagnostic techniques adopted. As the diagnostic techniques applied in each system are limited, and machinery defects can have different physical nature, it becomes necessary to combine several diagnostics and monitoring systems to control various machinery components. Such an approach is inconvenient, since it requires additional measures to bring the diagnostic results in a single view of the technical condition of production assets. In this case, we mean by a production facility a bonded complex of a process unit, a drive, a power source and lines. A failure of any of these components will cause an outage of the production asset, which is unacceptable. The purpose of the study is to test a combined use of vibration diagnostics and partial discharge techniques within the diagnostic systems of enterprises for automated control of the technical condition of rotating machinery during maintenance and at production facilities. The described solutions allow you to control the condition of mechanical and electrical components of rotating machines. It is shown that the functionality of the diagnostics systems can be expanded with minimal changes in technological chains of repair and operation of rotating machinery. Automation of such systems reduces the influence of the human factor on the quality of repair and diagnostics of the machinery.

  7. Nailfold capillaroscopy as a diagnostic and prognostic method in rosacea.

    Science.gov (United States)

    Fonseca, Gabriela Poglia; Brenner, Fabiane Mulinari; Muller, Carolina de Souza; Wojcik, Adma Lima

    2011-01-01

    There is no appropriate and reliable method of evaluating and monitoring severity in rosacea. To determine the importance of nailfold capillaroscopy as a diagnostic and prognostic method for patients with rosacea. A cross-sectional study where eight patients with rosacea and 8 control subjects were submitted to nailfold capillaroscopy from May to July 2009. We collected clinical data related to gender, age, skin phototype, and rosacea stage according to Plewig and Kligman classification and the classification of the National Rosacea Society. Additionally, we evaluated the progression of the disease and treatment therapies previously used. The majority of the patients evaluated (6 out of 8 patients) had rosacea subtype I (vascular) or erythematotelangiectatic rosacea. The mean duration of the disorder was 5.96 years, and 87.5% of the patients were under treatment with topical metronidazole. Nailfold cappilaroscopy showed that evidence of devascularization was absent in both groups. Nailfold capillaroscopy presents a nonspecific pattern and does not seem to help in the diagnosis or prognosis of rosacea.

  8. Basic artefacts of diagnostic imaging by the magnetic resonance method

    International Nuclear Information System (INIS)

    Vitak, T.; Seidl, Z.; Obenberger, J.; Vaneckova, M.; Danes, J.; Krasensky, J.; Peterkova, V

    2000-01-01

    Artefacts in diagnostic imaging are defined as a geometric or anatomic misrepresentation of the reality by the image formed. The article deals with artefacts due to field and frequency shifts, in particular due to the water-fat chemical shift and due to magnetic susceptibility. The physical nature of the artefacts is explained and their diagnostic significance is discussed. (P.A.)

  9. Laboratory diagnostic methods, system of quality and validation

    Directory of Open Access Journals (Sweden)

    Ašanin Ružica

    2005-01-01

    Full Text Available It is known that laboratory investigations secure safe and reliable results that provide a final confirmation of the quality of work. Ideas, planning, knowledge, skills, experience, and environment, along with good laboratory practice, quality control and reliability of quality, make the area of biological investigations very complex. In recent years, quality control, including the control of work in the laboratory, is based on international standards and is used at that level. The implementation of widely recognized international standards, such as the International Standard ISO/IEC 17025 (1 and the implementing of the quality system series ISO/IEC 9000 (2 have become the imperative on the grounds of which laboratories have a formal, visible and corresponding system of quality. The diagnostic methods that are used must constantly yield results which identify the animal as positive or negative, and the precise status of the animal is determined with a predefined degree of statistical significance. Methods applied on a selected population reduce the risk of obtaining falsely positive or falsely negative results. A condition for this are well conceived and documented methods, with the application of the corresponding reagents, and work with professional and skilled staff. This process requires also a consistent implementation of the most rigorous experimental plans, epidemiological and statistical data and estimations, with constant monitoring of the validity of the applied methods. Such an approach is necessary in order to cut down the number of misconceptions and accidental mistakes, for a referent population of animals on which the validity of a method is tested. Once a valid method is included in daily routine investigations, it is necessary to apply constant monitoring for the purpose of internal quality control, in order adequately to evaluate its reproducibility and reliability. Consequently, it is necessary at least twice yearly to conduct

  10. Special Education--Non-Special Education Achievement Gap in Math: Effects of Reporting Methods, Analytical Techniques, and Reclassification

    Science.gov (United States)

    Thurlow, Martha L.; Wu, Yi-Chen; Lazarus, Sheryl S.; Ysseldyke, James E.

    2016-01-01

    Federal regulations indicate that the achievement gap must be closed between subgroups, including the gap between special education and non-special education students. We explored the ways in which achievement trends are influenced by three methods of reporting (cross-sectional, cohort-static, and cohort-dynamic). We also investigated (a) the ways…

  11. Requesting diagnostic imaging examinations: a position paper of the Canadian Association of Radiologists. Special article

    International Nuclear Information System (INIS)

    Stolberg, H.O.; Hynes, D.M.; Rainbow, A.J.; Moran, L.A.

    1997-01-01

    The present document is directed at physicians who request diagnostic imaging examinations. Many of the imaging examinations currently requested are not useful in managing clinical problems. The intention is to provide general guidelines for the prescription of appropriate imaging examinations. This document does not address the use of specific imaging modalities in particular clinical situations. The purpose is to help doctors make the best use of the imaging examination by providing general guidelines to assist in deciding upon the most appropriate situation in which to use the examination. Similar guidelines for the prescription of diagnostic x-ray examinations have been suggested previously. (author). 19 refs.,

  12. Theories and Diagnostic Methods of Land Use Conflicts

    Institute of Scientific and Technical Information of China (English)

    Yongfang; YANG; Lianqi; ZHU

    2013-01-01

    With social and economic development, the land resources are becoming increasingly scarce, and the land use conflicts are getting more frequent, deeper, more diversified and more severe. Besides, the factors that induce land use conflicts are more and more complicated. Therefore, the key to solve many difficult problems in regional sustainable land use lies in the research of land use conflicts, scientific evaluation of the intensity of regional land use conflicts, and the further reveal of external forms as well as intrinsic mechanisms of land use conflicts. Based on the review of both domestic and foreign literatures, this paper has completed the theoretical framework as well as the contents of land use conflicts research, established the diagnostic models and methods of land use conflicts intensity and proposed the key research areas of future studies. The purpose is to promote the evolution of spatial structure of China’s land resources to the positive direction and achieve integrated and coordinated management of land use through improving spatial allocation efficiency of land factors and buffering the pressure on land resources.

  13. Laser induced desorption as hydrogen retention diagnostic method

    Energy Technology Data Exchange (ETDEWEB)

    Zlobinski, Miroslaw

    2016-07-15

    Laser Induced Desorption Spectroscopy (LIDS) is a diagnostic method to measure the hydrogen content in the surface of a material exposed to a hydrogen isotope (H,D,T) plasma. It is developed mainly to monitor hydrogen retention in the walls of magnetic fusion devices that have to limit the amount of their fuel tritium mainly due to safety reasons. The development of fusion increasingly focusses on plasma-wall interactions for which in situ diagnostics like LIDS are required that work during plasma operation and without tile removal. The method has first been developed for thin amorphous hydrocarbon (a-C:H < 500 nm) layers successfully and is studied in the present work on thick (15 μm) layers, carbon fibre composites (CFCs), bulk tungsten (W), W fuzz and mixed C/W materials. In LID a 3 ms Nd:YAG (1064 nm) laser pulse heats a spot of diameter 3 mm with 500 {sup MW}/{sub m{sup 2}} on W to 1800 K at the surface and thus above 1300 K within ca. 0.2 mm depth. On C materials (graphite, CFC, a-C:H) this temperature guarantees a nearly complete (>95%) desorption already within 1.5 ms pulse duration. The retained hydrogen atoms are desorbed locally, recombine to molecules and migrate promptly to the surface via internal channels like pores and grain boundaries. Whereas, in W the retained hydrogen atoms have to diffuse through the bulk material, which is a relatively slow process also directed into the depth. The desorbed hydrogen fraction can thus be strongly reduced to 18-91% as observed here. This fraction is measured by melting the central part of a previously heated spot ca. 40 μm deep with a diameter 2 mm, 3 ms laser pulse, releasing the remaining hydrogen. W samples exposed to different plasmas in TEXTOR, Pilot-PSI, PSI-2, PADOS and PlaQ show that the desorption fraction of LID mainly decreases due to higher sample temperature during plasma exposure. The heat causes deeper hydrogen diffusion and/or stronger hydrogen trapping due to creation of traps with higher

  14. Laser induced desorption as hydrogen retention diagnostic method

    International Nuclear Information System (INIS)

    Zlobinski, Miroslaw

    2016-01-01

    Laser Induced Desorption Spectroscopy (LIDS) is a diagnostic method to measure the hydrogen content in the surface of a material exposed to a hydrogen isotope (H,D,T) plasma. It is developed mainly to monitor hydrogen retention in the walls of magnetic fusion devices that have to limit the amount of their fuel tritium mainly due to safety reasons. The development of fusion increasingly focusses on plasma-wall interactions for which in situ diagnostics like LIDS are required that work during plasma operation and without tile removal. The method has first been developed for thin amorphous hydrocarbon (a-C:H < 500 nm) layers successfully and is studied in the present work on thick (15 μm) layers, carbon fibre composites (CFCs), bulk tungsten (W), W fuzz and mixed C/W materials. In LID a 3 ms Nd:YAG (1064 nm) laser pulse heats a spot of diameter 3 mm with 500 MW / m 2 on W to 1800 K at the surface and thus above 1300 K within ca. 0.2 mm depth. On C materials (graphite, CFC, a-C:H) this temperature guarantees a nearly complete (>95%) desorption already within 1.5 ms pulse duration. The retained hydrogen atoms are desorbed locally, recombine to molecules and migrate promptly to the surface via internal channels like pores and grain boundaries. Whereas, in W the retained hydrogen atoms have to diffuse through the bulk material, which is a relatively slow process also directed into the depth. The desorbed hydrogen fraction can thus be strongly reduced to 18-91% as observed here. This fraction is measured by melting the central part of a previously heated spot ca. 40 μm deep with a diameter 2 mm, 3 ms laser pulse, releasing the remaining hydrogen. W samples exposed to different plasmas in TEXTOR, Pilot-PSI, PSI-2, PADOS and PlaQ show that the desorption fraction of LID mainly decreases due to higher sample temperature during plasma exposure. The heat causes deeper hydrogen diffusion and/or stronger hydrogen trapping due to creation of traps with higher binding energy

  15. Efficient diagnostic methods for nuclear power plant monitoring

    International Nuclear Information System (INIS)

    Sunder, R.

    1997-01-01

    There are systems for operational monitoring of vibrations, valves, solid-borne sound, leaks, and embrittlement. The paper focuses on vibration monitoring of pressurized components and systems in PWRs and BWRs. Other than with conventional systems, the task is not to globally monitor the vibration level, but the frequency-selective information is used as a sensitive information source, the level of vibrations being of secondary significance. The essential feature therefore is the comprehensive and selective scanning of individual frequency components in the recorded vibration spectra, which in some cases can be less than a millesimal millimeter. Upon identification of the various vibration components - from so-called baseline analyses using correlation methods - vibration analysis is done by only one step, comparing a defined reference state with the actual vibration state of the monitored system component. In the event of detected deviations, information on the causes of vibrations - essentially component-related structural resonances - will give the relevant cause-effect relationship. The paper uses some practical examples to illustrate that reliable diagnoses are achieved by the above-mentioned frequency-selective technique. It is important, however, to carry out a sufficiently reliable statistical verification of diagnostic data by means of vibration trending. This is ensured with the digital systems and their high data acquisition rates. (orig./CB) [de

  16. Mammary carcinoma – current diagnostic methods and symptomatology in imaging studies

    International Nuclear Information System (INIS)

    Popiel, Monika; Mróz-Klimas, Danuta; Kasprzak, Renata; Furmanek, Mariusz

    2012-01-01

    Breast cancer is the most common neoplasm of the female population and its incidence is constantly rising. Social campaigns educating the public about the importance of the problem have been conducted for the past several years. Women are encouraged to self-examine on a monthly basis. Women aged 50–69 years can have an x-ray mammography performed once every 2 years as part of a prophylactic screening program. Ultrasound studies or MR mammography are adjuvant or, in some cases, alternative to x-ray mammography. Nuclear medicine techniques with application of oncophilic markers and receptor studies (this publication will not cover nuclear medicine methods) are not routinely used. Other techniques, such as computed tomography and conventional radiography are of no significance in the diagnostics of mammary cancer. However, together with isotopic methods, they are helpful in staging of the disease. X-ray mammography is, up to date, the only method with proven value in decreasing mortality. It is also the best available method for visualization of microcalicifications. Ultrasound examination is complementary to x-ray mammography as it is a cheap, easily available method of imaging mammary glands with higher glandular tissue content. It is also the most commonly used modality aiding in targeted biopsy of mammary gland. To date, MR mammography, characterized by the highest sensitivity in cancer diagnostics, remained a method reserved for “special tasks”. MR is used for prophylaxis mainly in a population of women with particularly high risk of the disease and in cases where x-ray and ultrasound examinations are insufficient. Picture of mammary carcinoma in imaging studies is heterogeneous. However, it most often presents as an irregularly demarcated mass. Moreover, each modality can aid in visualization of additional features of a lesion such as typical shape of microcalcifications in x-ray mammography, characteristic pattern of contrast enhancement in MR examination

  17. Validation Tools and Methods for Diagnostic Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The potential benefits of advanced algorithms for diagnostics and prognostics, inner-loop control, and other flight critical systems have been demonstrated in a...

  18. THE HARMONIZATION AND OPTIMIZATION OF DIAGNOSTIC METHODS FOR A BELT CONVEYOR

    Directory of Open Access Journals (Sweden)

    František HELEBRANT

    2012-04-01

    Full Text Available The final aim of the project MPO FR‐T11/537 called “The Complex Diagnostic System for the Belt Transport” is a single part custom manufacturing and sale of complex diagnostic system for belt transportation and related services. The output of the project is a prototype of a diagnostic system on a model belt conveyor with prepared and certified diagnostic services and methods including their measurements and other supportive tools. The article will introduce the present state of the solution for the given grant project, especially in the field of suggested work on the diagnostic and supportive methods and other measurements.

  19. The new null testing method for the special optical window

    Science.gov (United States)

    Huang, Changchun

    2009-07-01

    The high speed, high precision and wide range specifications are requirement for the modern aircraft, which the traditional hemispherical dome can't achieve now, and the novel conformal window instead can enhance the aerodynamic performance of the aircraft obviously. To reduce the aerodynamic drag and radar cross-section, the window geometry is generally aspheric in shape. As a result, the involved fabrication and testing processes are much more challenging than that of conventional optics and must be mastered before these windows and systems can be implemented at an acceptable cost and risk. Metrology is one of the critical areas required to advance the conformal window technology. But as the surface of these conformal windows is not the traditional sphere lens, the measurement method for it is infeasible with the conventional optics measurement processes. This paper we express the development of testing technology for the special conformal windows in brief, and emphatically introduces one available novel testing method- a new null testing, and here based on the theory of compensation methods, The principle of Offner's refractive null lens has been extended to test the transmission wavefront through conformal window optics and provide feedback during surface fabrication. a compensator system for the was designed for the conformal window is given which parameters are 100mm for its aperture and two parabolic surface as conformal window, the final residual wavefront error(RMS) of which is less than 1/20λ(λ=632.8nm).

  20. Classification of Specialized Farms Applying Multivariate Statistical Methods

    Directory of Open Access Journals (Sweden)

    Zuzana Hloušková

    2017-01-01

    Full Text Available Classification of specialized farms applying multivariate statistical methods The paper is aimed at application of advanced multivariate statistical methods when classifying cattle breeding farming enterprises by their economic size. Advantage of the model is its ability to use a few selected indicators compared to the complex methodology of current classification model that requires knowledge of detailed structure of the herd turnover and structure of cultivated crops. Output of the paper is intended to be applied within farm structure research focused on future development of Czech agriculture. As data source, the farming enterprises database for 2014 has been used, from the FADN CZ system. The predictive model proposed exploits knowledge of actual size classes of the farms tested. Outcomes of the linear discriminatory analysis multifactor classification method have supported the chance of filing farming enterprises in the group of Small farms (98 % filed correctly, and the Large and Very Large enterprises (100 % filed correctly. The Medium Size farms have been correctly filed at 58.11 % only. Partial shortages of the process presented have been found when discriminating Medium and Small farms.

  1. Inservice diagnostic methods for solenoid-operated valves

    International Nuclear Information System (INIS)

    Kryter, R.C.

    1993-01-01

    Solenoid-operated valves (SOVs) were studied at Oak Ridge National Laboratory as part of the USNRC Nuclear Plant Aging Research (NPAR) Program. The primary objective of the study was to identify, evaluate, and recommend methods for inspection, surveillance, monitoring, and maintenance of SOVs that can help ensure their operational readiness-that is, their ability to perform required safety functions under all anticipated operating conditions, since failure of one of these small and relatively inexpensive devices could have serious consequences under certain circumstances. An earlier (Phase 1) NPAR program study described SOV failure modes and causes and had identified measurable parameters thought to be linked to the progression of everpresent degradation mechanisms that may ultimately result in functional failure of the valve. Using this earlier work as a guide, the present (Phase 11) study focused on devising and then demonstrating the effectiveness of techniques and equipment with which to measure performance parameters that show promise for detecting the presence and trending the progress of such degradations before they reach a critical stage. Intrusive techniques requiring the addition of magnetic or acoustic sensors or the application of special test signals were investigated briefly, but major emphasis was placed on the examination of condition-indicating techniques that can be applied with minimal cost and impact on plant operation. Experimental results are presented that demonstrate the technical feasibility and practicality of the monitoring techniques assessed in the study, and recommendations for further work are provided

  2. Dental and dental hygiene students' diagnostic accuracy in oral radiology: effect of diagnostic strategy and instructional method.

    Science.gov (United States)

    Baghdady, Mariam T; Carnahan, Heather; Lam, Ernest W N; Woods, Nicole N

    2014-09-01

    There has been much debate surrounding diagnostic strategies and the most appropriate training models for novices in oral radiology. It has been argued that an analytic approach, using a step-by-step analysis of the radiographic features of an abnormality, is ideal. Alternative research suggests that novices can successfully employ non-analytic reasoning. Many of these studies do not take instructional methodology into account. This study evaluated the effectiveness of non-analytic and analytic strategies in radiographic interpretation and explored the relationship between instructional methodology and diagnostic strategy. Second-year dental and dental hygiene students were taught four radiographic abnormalities using basic science instructions or a step-by-step algorithm. The students were tested on diagnostic accuracy and memory immediately after learning and one week later. A total of seventy-three students completed both immediate and delayed sessions and were included in the analysis. Students were randomly divided into two instructional conditions: one group provided a diagnostic hypothesis for the image and then identified specific features to support it, while the other group first identified features and then provided a diagnosis. Participants in the diagnosis-first condition (non-analytic reasoning) had higher diagnostic accuracy then those in the features-first condition (analytic reasoning), regardless of their learning condition. No main effect of learning condition or interaction with diagnostic strategy was observed. Educators should be mindful of the potential influence of analytic and non-analytic approaches on the effectiveness of the instructional method.

  3. Review of Dercum’s disease and proposal of diagnostic criteria, diagnostic methods, classification and management

    Directory of Open Access Journals (Sweden)

    Hansson Emma

    2012-04-01

    Full Text Available Abstract Definition and clinical picture We propose the minimal definition of Dercum’s disease to be generalised overweight or obesity in combination with painful adipose tissue. The associated symptoms in Dercum’s disease include fatty deposits, easy bruisability, sleep disturbances, impaired memory, depression, difficulty concentrating, anxiety, rapid heartbeat, shortness of breath, diabetes, bloating, constipation, fatigue, weakness and joint aches. Classification We suggest that Dercum’s disease is classified into: I. Generalised diffuse form A form with diffusely widespread painful adipose tissue without clear lipomas, II. Generalised nodular form - a form with general pain in adipose tissue and intense pain in and around multiple lipomas, and III. Localised nodular form - a form with pain in and around multiple lipomas IV. Juxtaarticular form - a form with solitary deposits of excess fat for example at the medial aspect of the knee. Epidemiology Dercum’s disease most commonly appears between the ages of 35 and 50 years and is five to thirty times more common in women than in men. The prevalence of Dercum’s disease has not yet been exactly established. Aetiology Proposed, but unconfirmed aetiologies include: nervous system dysfunction, mechanical pressure on nerves, adipose tissue dysfunction and trauma. Diagnosis and diagnostic methods Diagnosis is based on clinical criteria and should be made by systematic physical examination and thorough exclusion of differential diagnoses. Advisably, the diagnosis should be made by a physician with a broad experience of patients with painful conditions and knowledge of family medicine, internal medicine or pain management. The diagnosis should only be made when the differential diagnoses have been excluded. Differential diagnosis Differential diagnoses include: fibromyalgia, lipoedema, panniculitis, endocrine disorders, primary psychiatric disorders, multiple symmetric lipomatosis, familial

  4. Diagnostic Vocational Assessment for Special Needs Student Candidates for Vocational Training.

    Science.gov (United States)

    Blackstone Valley Regional Vocational School District, Upton, MA.

    A project was conducted to bridge the gap between the coneptualized model of vocational evaluation within a rehabilitation framework and the needs of a changing career development model within an educational setting. The project focus was on ascertaining the state of the art of vocational assessment of special needs individuals, then building a…

  5. Fuzzy based method for project planning of the infrastructure design for the diagnostic in ITER

    International Nuclear Information System (INIS)

    Piros, Attila; Veres, Gábor

    2013-01-01

    The long-term design projects need special preparation before the start of the execution. This preparation usually includes the drawing of the network diagram for the whole procedure. This diagram includes the time estimation of the individual subtasks and gives us information about the predicted dates of the milestones. The calculated critical path in this network characterizes a specific design project concerning to its duration very well. Several methods are available to support this step of preparation. This paper describes a new method to map the structure of the design process and clarify the milestones and predict the dates of these milestones. The method is based on the PERT (Project Evaluation and Review Technique) network but as a novelty it applies fuzzy logic to find out the concerning times in this graph. With the application of the fuzzy logic the handling of the different kinds of design uncertainties becomes feasible. Many kinds of design uncertainties exist from the possible electric blackout up to the illness of an engineer. In many cases these uncertainties are related with human errors and described with linguistic expressions. The fuzzy logic enables to transform these ambiguous expressions into numeric values for further mathematical evaluation. The method is introduced in the planning of the design project of the infrastructure for the diagnostic systems of ITER. The method not only helps the project in the planning phase, but it will be a powerful tool in mathematical modeling and monitoring of the project execution

  6. Fuzzy based method for project planning of the infrastructure design for the diagnostic in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Piros, Attila, E-mail: attila.piros@gt3.bme.hu [Department of Machine and Product Design, Budapest University of Technology and Economics, Budapest (Hungary); Veres, Gábor [Department of Plasma Physics, Wigner Research Centre for Physics, Hungarian Academy of Sciences, Budapest (Hungary)

    2013-10-15

    The long-term design projects need special preparation before the start of the execution. This preparation usually includes the drawing of the network diagram for the whole procedure. This diagram includes the time estimation of the individual subtasks and gives us information about the predicted dates of the milestones. The calculated critical path in this network characterizes a specific design project concerning to its duration very well. Several methods are available to support this step of preparation. This paper describes a new method to map the structure of the design process and clarify the milestones and predict the dates of these milestones. The method is based on the PERT (Project Evaluation and Review Technique) network but as a novelty it applies fuzzy logic to find out the concerning times in this graph. With the application of the fuzzy logic the handling of the different kinds of design uncertainties becomes feasible. Many kinds of design uncertainties exist from the possible electric blackout up to the illness of an engineer. In many cases these uncertainties are related with human errors and described with linguistic expressions. The fuzzy logic enables to transform these ambiguous expressions into numeric values for further mathematical evaluation. The method is introduced in the planning of the design project of the infrastructure for the diagnostic systems of ITER. The method not only helps the project in the planning phase, but it will be a powerful tool in mathematical modeling and monitoring of the project execution.

  7. Personalised medicine in 2012: editorial to the special issue of New Biotechnology on "molecular diagnostics & personalised medicine".

    Science.gov (United States)

    Desiere, Frank; Romano Spica, Vincenzo

    2012-09-15

    This special issue of New Biotechnology is focused on molecular diagnostics and personalised medicine and appears at an epochal moment in the development of the field. The practice of medicine is taking a significant and irrevocable turn towards personalisation, due to the great progress in areas such as genomics, pharmacogenomics and molecular diagnosis. It becomes increasingly apparent that to deliver the promise of personalised treatments, more and more novel medicines discovered today will be presented together with innovative companion diagnostics. The contributions to this volume touch on many disciplines, ranging from cell biology to genetics, immunology, molecular diagnostics, pharmaceutics and economic issues. The contributions of clinicians and basic scientists are synergistically presented to underline better the wide spectrum of studies that can contribute to the new field of personalised medicine. The promising perspectives of individualised treatments are related not only to higher effectiveness, but also to increased efficiency. This is relevant not only for the individual patient, but even more so for the general public, within a wider economical perspective where resources are limited and it becomes more and more mandatory to close the gap between social costs and benefits. This approach follows the steps of a stratified and individualised medicine and finds its final goal in an individualised healthcare. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Diagnostic methods and techniques in cervical cancer prevention Part II: Molecular diagnostics of HPV infection

    Directory of Open Access Journals (Sweden)

    Adriana Vince,

    2010-02-01

    Full Text Available Clinical diagnostics of HPV infection is based on analytically andclinically validated assays for qualitative detection of HPV DNAfrom high risk genotypes. New generation of HPV DNA assayscombines qualitative detection of 12 high-risk HPV genotypeswith HPV-16 and HPV-18 genotyping. New generation of HPVmolecular assays designed to increase clinical specificity of moleculartesting is based on detection of mRNA for E6 and E7.

  9. Diagnostic examination of the urethra in the female and double-balloon urethrography as a diagnostic method

    International Nuclear Information System (INIS)

    Madeja, C.; Mutze, S.; Poetzschke, B.; Tunn, R.; Heinrich, G.; Hamm, B.

    1997-01-01

    The double-balloon urethrography can be recommended as an efficient diagnostic method for examination of the urethra in the female patient. Because of its improved controllability, retrograde application of the contrast agent is superior to other techniques. Complications can be avoided by maintaining constant pressure during contrast agent application. The few commercially available double-balloon instruments suffer from a number of deficiencies which are the reason for this technique having met with low acceptance, thus being only rarely applied. In addition, application of the instrument is not easy. Nevertheless, this diagnostic technique would deserve much more frequent application. (orig.) [de

  10. A new method of diagnostics for the magnetospheric plasma

    International Nuclear Information System (INIS)

    Etcheto, Jacqueline; Petit, Michel

    1977-01-01

    A new diagnostic technique for magnetospheric plasma, based on in situ excitation of the plasma resonances, has been used for the first time on board the Geos satellite. The preliminary results are very gratifying: electron density and magnetic field intensity are derived reliably and accurately from the resonances observed; hopefully, temperature and electric field will be deduced from the data as well [fr

  11. Sherlock Holmes's Methods of Deductive Reasoning Applied to Medical Diagnostics

    Science.gov (United States)

    Miller, Larry

    1985-01-01

    Having patterned the character of Sherlock Holmes after one of his professors, Sir Arthur Conan Doyle, himself a physician, incorporated many of the didactic qualities of the 19th century medical diagnostician into the character of Holmes. In this paper I explore Holmes's techniques of deductive reasoning and their basis in 19th and 20th century medical diagnostics. PMID:3887762

  12. Sherlock Holmes' methods of deductive reasoning applied to medical diagnostics.

    Science.gov (United States)

    Miller, L

    1985-03-01

    Having patterned the character of Sherlock Holmes after one of his professors, Sir Arthur Conan Doyle, himself a physician, incorporated many of the didactic qualities of the 19th century medical diagnostician into the character of Holmes. In this paper I explore Holmes's techniques of deductive reasoning and their basis in 19th and 20th century medical diagnostics.

  13. Special examinations in neuroradiology diagnostic of the neurological complications in atlanto axial dislocations

    International Nuclear Information System (INIS)

    Mihale, J.

    1998-01-01

    We report about contribution myelography, CT myelography, vertebral angiography and angio-cinematography, CT and MRI in diagnostic of the neurological complications of the ventral atlanto axial dislocation in 126 patients with progressive polyarthritis and ankylosing spondylarthritis. On the myelogram, and CT myelogram we visualized narrowing of the spinal channel in ventral atlanto axial dislocation. In patients with unreponibile dislocation up to the stop contrast medium between C1 and C2 vertebrae. With vertebral angiography and angio-cinematography we visualized changes in course of the arteries until with stop of the contrast medium in ante-flexion of the head in patients with unreponibile atlanto axial dislocation. On the MRI studies we visualized pathological changes in the front and back of the atlanto odontoidal joints and compression of the spinal cord. (author)

  14. Some non-LTE diagnostic methods for hydrogen plasmas

    International Nuclear Information System (INIS)

    Eddy, T.L.; Cho, K.Y.

    1986-01-01

    This paper shows that if electric and magnetic fields are not negligible, then the 2-T model assumed by many non-LTE plasma diagnostic techniques may lead to serious errors. Significant difference between T e and T ex have been shown to exist with electric field strengths as low as ∼10 V/cm. Multithermal equilibrium (MTE) calculations show significant deviations in line emission coefficients when T e ≠ T ex compared to equivalent T e ≠ T q . A quasi non-dimentional MTE continuum relation is present to assist in diagnostics. Normalized line emission coefficients verses N e are used to indicate the type and extent of non-LTE. The MTE state diagram for hydrogen is used to show why non-LTE plasmas often appear to be in LTE based on N e determinations

  15. Estimation methods for process holdup of special nuclear materials

    International Nuclear Information System (INIS)

    Pillay, K.K.S.; Picard, R.R.; Marshall, R.S.

    1984-06-01

    The US Nuclear Regulatory Commission sponsored a research study at the Los Alamos National Laboratory to explore the possibilities of developing statistical estimation methods for materials holdup at highly enriched uranium (HEU)-processing facilities. Attempts at using historical holdup data from processing facilities and selected holdup measurements at two operating facilities confirmed the need for high-quality data and reasonable control over process parameters in developing statistical models for holdup estimations. A major effort was therefore directed at conducting large-scale experiments to demonstrate the value of statistical estimation models from experimentally measured data of good quality. Using data from these experiments, we developed statistical models to estimate residual inventories of uranium in large process equipment and facilities. Some of the important findings of this investigation are the following: prediction models for the residual holdup of special nuclear material (SNM) can be developed from good-quality historical data on holdup; holdup data from several of the equipment used at HEU-processing facilities, such as air filters, ductwork, calciners, dissolvers, pumps, pipes, and pipe fittings, readily lend themselves to statistical modeling of holdup; holdup profiles of process equipment such as glove boxes, precipitators, and rotary drum filters can change with time; therefore, good estimation of residual inventories in these types of equipment requires several measurements at the time of inventory; although measurement of residual holdup of SNM in large facilities is a challenging task, reasonable estimates of the hidden inventories of holdup to meet the regulatory requirements can be accomplished through a combination of good measurements and the use of statistical models. 44 references, 62 figures, 43 tables

  16. Clinical Training of Medical Physicists Specializing in Diagnostic Radiology (Spanish Edition); Capacitacion clinica de fisicos medicos especialistas en radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-01-15

    The application of radiation in human health, for both diagnosis and treatment of disease, is an important component of the work of the IAEA. The responsibility for the increasing technical aspects of this work is undertaken by the medical physicist. To ensure good practice in this vital area, structured clinical training programmes are required to complement academic learning. This publication is intended to be a guide to the practical implementation of such a programme for diagnostic radiology. There is a general and growing awareness that radiation medicine is increasingly dependent on well trained medical physicists based in the clinical setting. However, an analysis of the availability of medical physicists indicates a large shortfall of qualified and capable professionals. This is particularly evident in developing countries. While strategies to increase academic educational opportunities are critical to such countries, the need for guidance on structured clinical training was recognized by the members of the Regional Cooperative Agreement (RCA) for Research, Development and Training related to Nuclear Sciences for Asia and the Pacific. Consequently, a technical cooperation regional project (RAS6038) under the RCA programme was formulated to address this need in the Asia-Pacific region by developing suitable material and establishing its viability. Development of a clinical training guide for medical physicists specializing in diagnostic radiology started in 2007 with the appointment of a core drafting committee of regional and international experts. The publication drew on the experiences of clinical training programmes in Australia and New Zealand, the UK and the USA, and was moderated by physicists working in the Asian region. This publication follows the approach of the IAEA publication Training Course Series No. 37, Clinical Training of Medical Physicists specializing in Radiation Oncology. This approach to clinical training has been successfully tested

  17. A comprehensive special educational diagnostic assessment of five-year-old children with developmental coordination disorder (case studies

    Directory of Open Access Journals (Sweden)

    Tjasa Filipcic

    2016-07-01

    Full Text Available Developmental coordination disorder (DCD is a neurodevelopmental disorder which affects different areas of an individual's everyday living and learning. Children with DCD are often diagnosed late, at school age, when difficulties with writing, organization and executive functions arise, even though one could have seen signs of probable DCD very early in childhood. The aim of this study was to further assess five-year-old, preschool children recognized as children with DCD, and develop a model for a comprehensive special educational diagnostic assessment of abilities and skills in five-year-old children with DCD. The comprehensive diagnostic assessment comprised observations and assessments of children’s everyday skills in their kindergartens. It also included semi-structured interviews with children, their parents and their preschool teachers. Further, children’s skills and abilities in all developmental domains (sensory and motor skills, cognitive abilities, social and emotional development, speech and language development, including emerging literacy skills, and early maths skills were assessed. A qualitative analysis was undertaken to compare individual children’s comprehensive assessments. The developed model included both the strengths and weaknesses of the assessed children.

  18. Method of reduction of diagnostic parameters during observation on the example of a combustion engine

    Directory of Open Access Journals (Sweden)

    Orczyk Malgorzata

    2017-01-01

    Full Text Available The article presents a method of selecting diagnostic parameters which map the process of damaging the object. This method consists in calculating, during the observation, the correlation coefficient between the intensity of damage and the individual diagnostic parameters; and discarding of those parameters whose correlation coefficient values are outside of the narrowest confidence interval of the correlation coefficient. The characteristic feature of this method is that the parameters are reduced during the diagnostic experiment. The essence of the proposed method is illustrated by the vibration diagnosis of an internal combustion engine.

  19. [Secondary forms of osteoporosis. Special features of diagnostics in childhood and adolescence].

    Science.gov (United States)

    Stark, C; Hoyer-Kuhn, H; Knoop, K; Schoenau, H; Schoenau, E; Semler, O

    2014-05-01

    Rheumatic diseases in childhood and adolescence can lead to secondary osteoporosis based on various pathophysiologies. The underlying disease, medication and immobility resulting in a reduced osteoanabolic stimulus contribute to the development of a fragile skeletal system. For diagnostic purposes dual-energy X-ray absorptiometry (DXA) is the most frequently used technology. For interpretation of the areal bone mineral density, age and gender matched reference data have to be used. Particularly in the pediatric field, body height must additionally be taken into consideration. Further techniques which can provide detailed information are peripheral quantitative computed tomography and high resolution magnetic resonance imaging. Nowadays, skeletal assessments have to be interpreted in the context of the muscular system. The concept of the functional muscle-bone unit is widely accepted and uses the muscles as the dominating factor. In a second step the adaptation of the skeletal system to the applied muscle force is evaluated. This allows a differentiation between primary and secondary skeletal diseases depending on the ratio of muscles to bone. Therapeutic options for secondary osteoporosis include reduction of the causative medication, treatment of the underlying disease, antiresorptive treatment with bisphosphonates and different programs to activate the muscles. A multimodal interval rehabilitation program including alternating side vibration shows positive effects on mobility, muscle function and bone mass in children and adolescents.

  20. Method matters: Understanding diagnostic reliability in DSM-IV and DSM-5.

    Science.gov (United States)

    Chmielewski, Michael; Clark, Lee Anna; Bagby, R Michael; Watson, David

    2015-08-01

    Diagnostic reliability is essential for the science and practice of psychology, in part because reliability is necessary for validity. Recently, the DSM-5 field trials documented lower diagnostic reliability than past field trials and the general research literature, resulting in substantial criticism of the DSM-5 diagnostic criteria. Rather than indicating specific problems with DSM-5, however, the field trials may have revealed long-standing diagnostic issues that have been hidden due to a reliance on audio/video recordings for estimating reliability. We estimated the reliability of DSM-IV diagnoses using both the standard audio-recording method and the test-retest method used in the DSM-5 field trials, in which different clinicians conduct separate interviews. Psychiatric patients (N = 339) were diagnosed using the SCID-I/P; 218 were diagnosed a second time by an independent interviewer. Diagnostic reliability using the audio-recording method (N = 49) was "good" to "excellent" (M κ = .80) and comparable to the DSM-IV field trials estimates. Reliability using the test-retest method (N = 218) was "poor" to "fair" (M κ = .47) and similar to DSM-5 field-trials' estimates. Despite low test-retest diagnostic reliability, self-reported symptoms were highly stable. Moreover, there was no association between change in self-report and change in diagnostic status. These results demonstrate the influence of method on estimates of diagnostic reliability. (c) 2015 APA, all rights reserved).

  1. Serological diagnosis of syphilis: a comparison of different diagnostic methods.

    Science.gov (United States)

    Simčič, Saša; Potočnik, Marko

    2015-01-01

    Serological tests' limitations in syphilis diagnosis as well as numerous test interpretations mean that patients with discordant serology results can present diagnostic and treatment challenges for clinicians. We analyzed three common diagnostic algorithms for detecting suspected syphilis in high-prevalence populations in Slovenia. The prospective study included a total of 437 clinical serum samples from adults throughout Slovenia tested with Rapid Plasma Reagin (RPR), Treponema pallidum hemagglutination (TPHA), and an automated chemiluminescence immunoassay (CIA) according to the manufacturer's instructions. In addition to percent agreement, kappa coefficients were calculated as a secondary measure of agreement between the three algorithms. Overall, of 183 subjects that had seroreactive results, 180 were seroreactive in both the reverse sequence and the European Centre for Disease Prevention and Control (ECDC) algorithm. The traditional algorithm had a missed serodiagnosis rate of 30.0%, the overall percent agreement between the traditional and the reverse algorithm (or the ECDC algorithm) was 87.6%, and the kappa value was 0.733. However, the reverse and ECDC algorithm failed to detect three subjects with positive serodiagnosis determined by additional confirmative treponemal assays. Our results supported the ECDC algorithm in the serodiagnosis of syphilis in high-prevalence populations and the use of nontreponemal serology to monitor the response to treatment.

  2. Development of wide area environment accelerator operation and diagnostics method

    Science.gov (United States)

    Uchiyama, Akito; Furukawa, Kazuro

    2015-08-01

    Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs), the use of standard protocols such as the hypertext transfer protocol (HTTP) is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN) faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.

  3. Studies of neutron measurement methods for fusion plasma diagnostics

    International Nuclear Information System (INIS)

    Beimer, K.H.

    1986-03-01

    This thesis comprises several studies mainly devoted to neutron measurement systems for plasma diagnostics at JET (Joint European Torus). An in situ calibration of the U-235 fission chamber detectors located at JET is presented. These detectors are used for measuring the neutron yield from the thermonuclear reactions in the plasma. The energy spectrum of the neutrons from the reactions D(d,n) 3 He has been studied by means of a 3 He spectrometer. Especially, it was found that by measuring the width of the full energy peak in the response spectrum of the 3 He-spectrometer, the deuterium distribution in the deuterium targets used can be estimated. In order to measure different neutron energies it is necessary to obtain a detailed knowledge of the response of the spectrometer. Therefore, the response function to monoenergetic neutrons in the energy range 130-3030 keV was experimentally determined. Some work has been related to a design study of a 14 MeV spectrometer for neutron diagnostics. It is a combined proton-recoil and time-of-flight spectrometer for high resolution measurements. The main parts of it are the collimator, the scattering foil, and the detectors for the recoil protons and the scattered neutrons. The influence of proton straggling in the foil on the resolution and efficiency of the spectrometer has been studied. Furthermore, a three dimensional Monte Carlo code has been written and used for the design of the collimator. (author)

  4. Development of wide area environment accelerator operation and diagnostics method

    Directory of Open Access Journals (Sweden)

    Akito Uchiyama

    2015-08-01

    Full Text Available Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs, the use of standard protocols such as the hypertext transfer protocol (HTTP is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.

  5. New method of leak detecting in diagnostic of gas pipeline system

    International Nuclear Information System (INIS)

    Kalinowski, K.; Dabrowski, A.; Sobkiewicz, D.; Oracz, H.

    2007-01-01

    This report describes new directions in gas transmission pipelines diagnostics as well as new methods and equipment used to detect leaks. It was also shown that efficient and functional diagnostics system is the necessary condition to keep the exploitation of transmission systems safe. (author)

  6. Research in Special Education: Designs, Methods, and Applications. Second Edition

    Science.gov (United States)

    Rumrill, Phillip D., Jr.; Cook, Bryan G.; Wiley, Andrew L.

    2011-01-01

    The goal of this second edition is to provide a comprehensive overview of the philosophical, ethical, methodological, and analytical fundamentals of social science and educational research, as well as specify aspects of special education research that distinguish it from scientific inquiry in other fields of education and human services. Foremost…

  7. Addressing the "Research Gap" in Special Education through Mixed Methods

    Science.gov (United States)

    Klingner, Janette K.; Boardman, Alison G.

    2011-01-01

    At least some of the challenges faced in special education, such as the disproportionate representation of culturally and linguistically diverse students, the gap between research and practice, and inequitable educational opportunities, can be explained in part by a research gap, or, in other words, a failure to conduct the different types of…

  8. A relaxation method with application in diagnostic radiology

    International Nuclear Information System (INIS)

    Herman, G.T.; Lent, A.H.

    1980-01-01

    Hildreth (1959) proposed an algorithm for optimizing positive definite quadratic forms subject to linear inequality constraints. Although Hildreth's original proof of the convergence of his procedure to a feasible vector optimizing the quadratic form was found to be not applicable to arbitrary inequality constraints sets, a general proof of convergence has recently been found. In this paper a way of substantially reducing the computer time and storage required by a Hildreth-type procedure when the inequality constraints have a special property is discussed. This property arises naturally in image reconstruction from projections. (Auth.)

  9. Using the method of judgement analysis to address variations in diagnostic decision making

    OpenAIRE

    Hancock, Helen C; Mason, James M; Murphy, Jerry J

    2012-01-01

    Abstract Background Heart failure is not a clear-cut diagnosis but a complex clinical syndrome with consequent diagnostic uncertainty. Judgment analysis is a method to help clinical teams to understand how they make complex decisions. The method of judgment analysis was used to determine the factors that influence clinicians' diagnostic decisions about heart failure. Methods Three consultants, three middle grade doctors, and two junior doctors each evaluated 45 patient scenarios. The main out...

  10. METHODS OF DIAGNOSTIC EFFECTIVENESS ORGANIZATIONAL CHANGES IN CARGO MOTOR TRANSPORTATION ORGANIZATIONS

    Directory of Open Access Journals (Sweden)

    Denis Sergeevich Antipov

    2017-03-01

    Full Text Available The article propose methods of diagnostic effectiveness organizational changes in cargo motor transportation organizations. The article contain the main results approbation of the developed methods of diagnostic effectiveness organizational changes in cargo motor transportation organizations in 37 cargo motor transportation organizations of Saint-Petersburg and the Leningrad Region. Constructed diagrams of conformity specific weights resulting from organizational changes in cargo motor transportation organizations. Presents diagrams effectiveness organizational changes in cargo motor transportation organizations at every stages of the life cycle. The goal of the present paper is to development methods of diagnostic effectiveness organizational changes in cargo motor transportation organizations.

  11. Non-Intrusive Optical Diagnostic Methods for Flowfield Characterization

    Science.gov (United States)

    Tabibi, Bagher M.; Terrell, Charles A.; Spraggins, Darrell; Lee, Ja. H.; Weinstein, Leonard M.

    1997-01-01

    Non-intrusive optical diagnostic techniques such as Electron Beam Fluorescence (EBF), Laser-Induced Fluorescence (LIF), and Focusing Schlieren (FS) have been setup for high-speed flow characterization and large flowfield visualization, respectively. Fluorescence emission from the First Negative band of N2(+) with the (0,0) vibration transition (at lambda =391.44 nm) was obtained using the EBF technique and a quenching rate of N2(+)* molecules by argon gas was reported. A very high sensitivity FS system was built and applied in the High-Speed Flow Generator (HFG) at NASA LaRC. A LIF system is available at the Advanced Propulsion Laboratory (APL) on campus and a plume exhaust velocity measurement, measuring the Doppler shift from lambda = 728.7 nm of argon gas, is under way.

  12. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    International Nuclear Information System (INIS)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE's nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer

  13. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE`s nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer.

  14. Methods of Verification, Accountability and Control of Special Nuclear Material

    International Nuclear Information System (INIS)

    Stewart, J.E.

    1999-01-01

    This session demonstrates nondestructive assay (NDA) measurement, surveillance and analysis technology required to protect, control and account (MPC and A) for special nuclear materials (SNM) in sealed containers. These measurements, observations and analyses comprise state-of-the art, strengthened, SNM safeguards systems. Staff member specialists, actively involved in research, development, training and implementation worldwide, will present six NDA verification systems and two software tools for integration and analysis of facility MPC and A data

  15. Application of the Monte Carlo method to diagnostic radiology

    International Nuclear Information System (INIS)

    Persliden, J.

    1986-01-01

    A Monte Carlo program for photon transport is developed. The program is used to investigate the energy imparted to water slabs (simulating patients), and the related backscattered and transmitted energies as functions of primary photon energy and water slab thickness. The accuracy of the results depends on the cross-section data for the probabilities of the various interactions in the slab and on the physical quantity calculated. Backscattered energy fractions can vary by as much as 10-20 %, using different sets of published data for the photoelectric cross section while imparted fractions are only slightly affected. The results are used to calculate improved conversion factors for determining the energy imparted to the patient in X-ray diagnostic examinations from measurements of the air collision kerma integrated over beam area. The small angle distribution of scattered photons transmitted through a water slab, relevant to problems of image quality, is calculated taking into account the diffraction phenomena of liquid water. The calculations are performed with a collision density estimator. This estimator makes it possible to calculate important physical quantities which are virtually impracticable to assess with the Monte Carlo codes commonly used in medical physics or in experiments. With the collision density estimator, the influence of air gaps on the reduction of scattered radiation is investigated for different detectors, field areas and primary X-ray spectra. Contrast degradation and contrast improvement factors are given as functions of field area for various air gaps. (With 105 refs.) (author)

  16. Most important methods of the diagnostics of air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Latocha, E; Cimander, B

    1976-01-01

    The paper contains a review of literature concerning the more important procedures for diagnosing air pollution. Cited results of studies from several countries indicate a relationship between the intensity of sulfur dioxide air pollution and the extent of vegetation damage. Possibility of the use of aerial photography for diagnosis of damage in forests was mentioned. Possibilities for utilization of certain plant species or plant communities as indicators of air pollution were described. It was stressed that long-lived evergreens are the best bio-indicators. Examples of increases in population density of certain insect pest sand activation of fungal pathogens caused by industrial emissions were given. Techniques used in Poland for the development and introduction of zones of forest threat by industrial air pollution were discussed. These are based on alterations in the length and shape of needles, foliage coloration, numbers of needle generations, and external appearance of tree crowns in the form of height growth inhibition or impairment of tree vigor. It was stressed that not all changes in forest environment under the impact of emissions may be considered appropriate for the diagnosis of air pollution. Diagnostic procedures ought to be relatively simple and easy to apply.

  17. Cognitive strategies: a method to reduce diagnostic errors in ER

    Directory of Open Access Journals (Sweden)

    Carolina Prevaldi

    2009-02-01

    Full Text Available I wonder why sometimes we are able to rapidly recognize patterns of disease presentation, formulate a speedy diagnostic closure, and go on with a treatment plan. On the other hand sometimes we proceed studing in deep our patient in an analytic, slow and rational way of decison making. Why decisions sometimes can be intuitive, while sometimes we have to proceed in a rigorous way? What is the “back ground noise” and the “signal to noise ratio” of presenting sintoms? What is the risk in premature labeling or “closure” of a patient? When is it useful the “cook-book” approach in clinical decision making? The Emergency Department is a natural laboratory for the study of error” stated an author. Many studies have focused on the occurrence of errors in medicine, and in hospital practice, but the ED with his unique operating characteristics seems to be a uniquely errorprone environment. That's why it is useful to understand the underlying pattern of thinking that can lead us to misdiagnosis. The general knowledge of thought processes gives the psysician awareness an the ability to apply different tecniques in clinical decision making and to recognize and avoid pitfalls.

  18. Specialized data analysis for the Space Shuttle Main Engine and diagnostic evaluation of advanced propulsion system components

    Science.gov (United States)

    1993-01-01

    The Marshall Space Flight Center is responsible for the development and management of advanced launch vehicle propulsion systems, including the Space Shuttle Main Engine (SSME), which is presently operational, and the Space Transportation Main Engine (STME) under development. The SSME's provide high performance within stringent constraints on size, weight, and reliability. Based on operational experience, continuous design improvement is in progress to enhance system durability and reliability. Specialized data analysis and interpretation is required in support of SSME and advanced propulsion system diagnostic evaluations. Comprehensive evaluation of the dynamic measurements obtained from test and flight operations is necessary to provide timely assessment of the vibrational characteristics indicating the operational status of turbomachinery and other critical engine components. Efficient performance of this effort is critical due to the significant impact of dynamic evaluation results on ground test and launch schedules, and requires direct familiarity with SSME and derivative systems, test data acquisition, and diagnostic software. Detailed analysis and evaluation of dynamic measurements obtained during SSME and advanced system ground test and flight operations was performed including analytical/statistical assessment of component dynamic behavior, and the development and implementation of analytical/statistical models to efficiently define nominal component dynamic characteristics, detect anomalous behavior, and assess machinery operational condition. In addition, the SSME and J-2 data will be applied to develop vibroacoustic environments for advanced propulsion system components, as required. This study will provide timely assessment of engine component operational status, identify probable causes of malfunction, and indicate feasible engineering solutions. This contract will be performed through accomplishment of negotiated task orders.

  19. The special features of cardiovascular pathology diagnostics in patients with epilepsy

    Directory of Open Access Journals (Sweden)

    Татьяна Анатольевна Литовченко

    2015-11-01

    Full Text Available Aim. The researchers noticed the changes of parameters of cardiovascular system functioning in patients with epilepsy during epileptic attacks and in interictal period. The aim of research was the study of informativity of the different methods of study of cardiovascular system functioning for detection and evaluation of risk of cardiac pathology development in patients with epilepsy.Materials and methods. We examined 50 patients with epilepsy and CVP and 50 patients with epilepsy without CVP. All patients underwent clinical and neurological examination, electrocardiography, echocardioscopy, examination of heart rhythm variability, dopplerography of carotid arteries, analysis of lipid blood spectrum, brain evaluation on indications on SCORE, МРТ.Results. There was revealed that the use of valproates and carbamazepine is associated with dyslipidemia development; valproates – with increase of intima-media complex thickness, cambamazepine – with increased risk of development of heart rhythm and conduction disorder; lamotrigine and levetiracetam – with increase of heart rate. The combined use of levetiracetam and carbamazepine is associated with extension of QT interval. The most significant increase of risk of CVP development during the next 10 years on SCORE was noticed in patients who take carbamazepine.Conclusions. The definition of intima-media complex thickness at dopplerography of carotid arteries, patients evaluation on SCORE, lipidograms, heart rhythm variability, definition of myocardial work index at echocardioscopy along with the standard ECG are effective for determination of risk factors and early detection of CVP in patients with epilepsy

  20. Specialized rheumatology nurse substitutes for rheumatologists in the diagnostic process of fibromyalgia: a cost-consequence analysis and a randomized controlled trial

    NARCIS (Netherlands)

    Kroese, Mariëlle E.; Severens, Johan L.; Schulpen, Guy J.; Bessems, Monique C.; Nijhuis, Frans J.; Landewé, Robert B.

    2011-01-01

    To perform a cost-consequence analysis of the substitution of specialized rheumatology nurses (SRN) for rheumatologists (RMT) in the diagnostic process of fibromyalgia (FM), using both a healthcare and societal perspective and a 9-month period. Alongside a randomized controlled trial, we measured

  1. Diagnostics of helium plasmas under special consideration of the continuous spectrum

    International Nuclear Information System (INIS)

    Einfeld, D.

    1974-01-01

    From measurements of the spectral beam density of the helium plasma in the region 290 nm to 650 nm, transition probabilities, Gaunt factors, line broadening parameters and deviations from the state of local thermodynamic equilibrium (L.T.E.) were determined and compared with theoretical data. Using the Gaunt factors experimentally secured in this work for the term n = 3, the electron density could be determined with an uncertainty of +-10% from the emission coefficients of the continuous spectrum. Assuming steady transition of the spectral emission coefficients over the series limit, a numerical method has been given according to which, amongst others, the Gaunt factors for the various series limits can be determined from the transition probabilities of these series. By determining the overpopulation factors of the ground states of the helium atom and the helium ion, a deviation from the L.T.E. state is experimentally detected and quantitatively described. (orig./LH) [de

  2. Electro-optic methods for longitudinal bunch diagnostics at FLASH

    International Nuclear Information System (INIS)

    Steffen, B.R.

    2007-07-01

    Precise measurements of the temporal profile of sub-picosecond electron bunches are of high interest for the optimization and operation of VUV and X-ray free electron lasers. In this thesis, the shortest electro-optic signals measured so far for electron bunch diagnostics are presented, reaching a time resolution of better than 50 fs (rms). The e ects that introduce signal distortions and limit the time resolution are studied in numerical simulations for different electro-optic detection materials and techniques. The time resolution is mainly limited by lattice resonances of the electro-optic crystal. Electro-optic signals as short as 54 fs (rms) are obtained with gallium phosphide (GaP) crystals in a crossed polarizer detection scheme using temporally resolved electro-optic detection. Measuring near crossed polarization, where the electro-optic signal is proportional to the velocity field of the relativistic electron bunch, the shortest obtained signal width is 70 fs (rms). The electro-optic signals are compared to electron bunch shapes that are measured simultaneously with a transverse deflecting structure with 20 fs resolution. Numerical simulations using the bunch shapes as determined with the transverse deflecting cavity as input data are in excellent agreement with electro-optical signals obtained with GaP, both for temporally and spectrally resolved measurements. In the case of zinc telluride (ZnTe) the observed signals are slightly broader and significantly smaller than expected from simulations. These discrepancies are probably due to the poor optical quality of the available ZnTe crystals. (orig.)

  3. Tokamak physics studies using x-ray diagnostic methods

    International Nuclear Information System (INIS)

    Hill, K.W.; Bitter, M.; von Goeler, S.

    1987-03-01

    X-ray diagnostic measurements have been used in a number of experiments to improve our understanding of important tokamak physics issues. The impurity content in TFTR plasmas, its sources and control have been clarified through soft x-ray pulse-height analysis (PHA) measurements. The dependence of intrinsic impurity concentrations and Z/sub eff/ on electron density, plasma current, limiter material and conditioning, and neutral-beam power have shown that the limiter is an important source of metal impurities. Neoclassical-like impurity peaking following hydrogen pellet injection into Alcator C and a strong effect of impurities on sawtooth behavior were demonstrated by x-ray imaging (XIS) measurements. Rapid inward motion of impurities and continuation of m = 1 activity following an internal disruption were demonstrated with XIS measurements on PLT using injected aluminum to enhance the signals. Ion temperatures up to 12 keV and a toroidal plasma rotation velocity up to 6 x 10 5 m/s have been measured by an x-ray crystal spectrometer (XCS) with up to 13 MW of 85-keV neutral-beam injection in TFTR. Precise wavelengths and relative intensities of x-ray lines in several helium-like ions and neon-like ions of silver have been measured in TFTR and PLT by the XCS. The data help to identify the important excitation processes predicted in atomic physics. Wavelengths of n = 3 to 2 silver lines of interest for x-ray lasers were measured, and precise instrument calibration techniques were developed. Electron thermal conductivity and sawtooth dynamics have been studied through XIS measurements on TFTR of heat-pulse propagation and compound sawteeth. A non-Maxwellian electron distribution function has been measured, and evidence of the Parail-Pogutse instability identified by hard x-ray PHA measurements on PLT during lower-hybrid current-drive experiments

  4. Electro-optic methods for longitudinal bunch diagnostics at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Steffen, B.R.

    2007-07-15

    Precise measurements of the temporal profile of sub-picosecond electron bunches are of high interest for the optimization and operation of VUV and X-ray free electron lasers. In this thesis, the shortest electro-optic signals measured so far for electron bunch diagnostics are presented, reaching a time resolution of better than 50 fs (rms). The e ects that introduce signal distortions and limit the time resolution are studied in numerical simulations for different electro-optic detection materials and techniques. The time resolution is mainly limited by lattice resonances of the electro-optic crystal. Electro-optic signals as short as 54 fs (rms) are obtained with gallium phosphide (GaP) crystals in a crossed polarizer detection scheme using temporally resolved electro-optic detection. Measuring near crossed polarization, where the electro-optic signal is proportional to the velocity field of the relativistic electron bunch, the shortest obtained signal width is 70 fs (rms). The electro-optic signals are compared to electron bunch shapes that are measured simultaneously with a transverse deflecting structure with 20 fs resolution. Numerical simulations using the bunch shapes as determined with the transverse deflecting cavity as input data are in excellent agreement with electro-optical signals obtained with GaP, both for temporally and spectrally resolved measurements. In the case of zinc telluride (ZnTe) the observed signals are slightly broader and significantly smaller than expected from simulations. These discrepancies are probably due to the poor optical quality of the available ZnTe crystals. (orig.)

  5. Comparative analysis of diagnostic performance, feasibility and cost of different test-methods for thyroid nodules with indeterminate cytology.

    Science.gov (United States)

    Sciacchitano, Salvatore; Lavra, Luca; Ulivieri, Alessandra; Magi, Fiorenza; De Francesco, Gian Paolo; Bellotti, Carlo; Salehi, Leila B; Trovato, Maria; Drago, Carlo; Bartolazzi, Armando

    2017-07-25

    Since it is impossible to recognize malignancy at fine needle aspiration (FNA) cytology in indeterminate thyroid nodules, surgery is recommended for all of them. However, cancer rate at final histology is blood assay.We performed systematic reviews and meta-analyses to compare their features, feasibility, diagnostic performance and cost. GEC, GEC+BRAF, M/F panel+miRNA GEC and M/F panel by NGS were the best in ruling-out malignancy (sensitivity = 90%, 89%, 89% and 90% respectively). BRAF and M/F panel alone and by NGS were the best in ruling-in malignancy (specificity = 100%, 93% and 93%). The M/F by NGS showed the highest accuracy (92%) and BRAF the highest diagnostic odds ratio (DOR) (247). GAL-3-ICC performed well as rule-out (sensitivity = 83%) and rule-in test (specificity = 85%), with good accuracy (84%) and high DOR (27) and is one of the cheapest (113 USD) and easiest one to be performed in different clinical settings.In conclusion, the more accurate molecular-based test-methods are still expensive and restricted to few, highly specialized and centralized laboratories. GAL-3-ICC, although limited by some false negatives, represents the most suitable screening test-method to be applied on a large-scale basis in the diagnostic algorithm of indeterminate thyroid lesions.

  6. Interlaboratory diagnostic accuracy of a Salmonella specific PCR-based method

    DEFF Research Database (Denmark)

    Malorny, B.; Hoorfar, Jeffrey; Hugas, M.

    2003-01-01

    A collaborative study involving four European laboratories was conducted to investigate the diagnostic accuracy of a Salmonella specific PCR-based method, which was evaluated within the European FOOD-PCR project (http://www.pcr.dk). Each laboratory analysed by the PCR a set of independent obtained...... presumably naturally contaminated samples and compared the results with the microbiological culture method. The PCR-based method comprised a preenrichment step in buffered peptone water followed by a thermal cell lysis using a closed tube resin-based method. Artificially contaminated minced beef and whole......-based diagnostic methods and is currently proposed as international standard document....

  7. Reliability studies of diagnostic methods in Indian traditional Ayurveda medicine

    DEFF Research Database (Denmark)

    Kurande, Vrinda Hitendra; Waagepetersen, Rasmus; Toft, Egon

    2013-01-01

    as prakriti classification), method development (pulse diagnosis), quality assurance for diagnosis and treatment and in the conduct of clinical studies. Several reliability studies are conducted in western medicine. The investigation of the reliability of traditional Chinese, Japanese and Sasang medicine...

  8. Diagnostic of the beam by pepper-pot method

    CERN Document Server

    Dolinskaya, M E; Zajchenko, A K

    2002-01-01

    The new method for the measuring of the particle distribution in the transversal plane with pepper-pot device is described. The algorithm for the beam emittance and Twiss parameters determination, using such measurements is presented. 7 refs., 8 figs.

  9. Automatic diagnostic methods of nuclear reactor collected signals

    International Nuclear Information System (INIS)

    Lavison, P.

    1978-03-01

    This work is the first phase of an opwall study of diagnosis limited to problems of monitoring the operating state; this allows to show all what the pattern recognition methods bring at the processing level. The present problem is the research of the control operations. The analysis of the state of the reactor gives a decision which is compared with the history of the control operations, and if there is not correspondence, the state subjected to the analysis will be said 'abnormal''. The system subjected to the analysis is described and the problem to solve is defined. Then, one deals with the gaussian parametric approach and the methods to evaluate the error probability. After one deals with non parametric methods and an on-line detection has been tested experimentally. Finally a non linear transformation has been studied to reduce the error probability previously obtained. All the methods presented have been tested and compared to a quality index: the error probability [fr

  10. Method for separation of uranium hexafluoride by specially activated carbons

    International Nuclear Information System (INIS)

    Bannasch, W.

    1976-01-01

    The present invention deals with the separation of urainium hexafluoride from gas streams on special activated carbon which can be released during an accident in nuclear plants. Those plants are concerned here in which as a rule uranium hexafluoride is handled in liquid aggregate state. The patent claims deal with the adsorption of UF 6 from gas mixtures in the temperature region of 70-200 0 C and the application of UF 6 adsorbing activated carbon of a certain grain based on petroleum and/or weight % and with a asch content of 4 to 6 weigt % and with a benzol yield of 50-60g benzene /100g activated carbon. (GG) [de

  11. Diagnostic Methods for Dental Caries Used by Private Dental ...

    African Journals Online (AJOL)

    2017-03-06

    Mar 6, 2017 ... methods used for diagnosis and treatment of dental caries can exhibit considerable differences. Oral health markedly contributes to the maintenance of general health and ..... may be attributed to the deterioration of eye function with the advanced ... meticulous visual examination of a dry tooth and the lack.

  12. Mapping the different methods adopted for diagnostic imaging instruction at medical schools in Brazil.

    Science.gov (United States)

    Chojniak, Rubens; Carneiro, Dominique Piacenti; Moterani, Gustavo Simonetto Peres; Duarte, Ivone da Silva; Bitencourt, Almir Galvão Vieira; Muglia, Valdair Francisco; D'Ippolito, Giuseppe

    2017-01-01

    To map the different methods for diagnostic imaging instruction at medical schools in Brazil. In this cross-sectional study, a questionnaire was sent to each of the coordinators of 178 Brazilian medical schools. The following characteristics were assessed: teaching model; total course hours; infrastructure; numbers of students and professionals involved; themes addressed; diagnostic imaging modalities covered; and education policies related to diagnostic imaging. Of the 178 questionnaires sent, 45 (25.3%) were completed and returned. Of those 45 responses, 17 (37.8%) were from public medical schools, whereas 28 (62.2%) were from private medical schools. Among the 45 medical schools evaluated, the method of diagnostic imaging instruction was modular at 21 (46.7%), classic (independent discipline) at 13 (28.9%), hybrid (classical and modular) at 9 (20.0%), and none of the preceding at 3 (6.7%). Diagnostic imaging is part of the formal curriculum at 36 (80.0%) of the schools, an elective course at 3 (6.7%), and included within another modality at 6 (13.3%). Professors involved in diagnostic imaging teaching are radiologists at 43 (95.5%) of the institutions. The survey showed that medical courses in Brazil tend to offer diagnostic imaging instruction in courses that include other content and at different time points during the course. Radiologists are extensively involved in undergraduate medical education, regardless of the teaching methodology employed at the institution.

  13. Apparatus and method for monitoring breath acetone and diabetic diagnostics

    Science.gov (United States)

    Duan, Yixiang [Los Alamos, NM; Cao, Wenqing [Los Alamos, NM

    2008-08-26

    An apparatus and method for monitoring diabetes through breath acetone detection and quantitation employs a microplasma source in combination with a spectrometer. The microplasma source provides sufficient energy to produce excited acetone fragments from the breath gas that emit light. The emitted light is sent to the spectrometer, which generates an emission spectrum that is used to detect and quantify acetone in the breath gas.

  14. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  15. Diagnostic and therapeutic capsules and method of producing

    International Nuclear Information System (INIS)

    Morcos, N.A.; Haney, T.A.; Wedeking, P.W.

    1981-01-01

    An article of manufacture comprising a pharmaceutical radioactive capsule formed essentially of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contract with fluids of the gastro-intestinal tract, and having a filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract said filler material being supported by said capsule. And a method of filling a pharmaceutical radioactive capsule comprising providing filler material supporting a pharmaceutically useful radioactive compound and transporting said filler material carrying a pharmaceutically useful radioactive compound into the chamber of said capsule

  16. Moessbauer methods and spectrometers specialized in qualitative and quantitative determinations

    International Nuclear Information System (INIS)

    Bibicu, I.

    1981-01-01

    A portable, field analyser devoted to fast qualitative and quantitative determination of cassiterite, which is the only tin compound of economic use in industry was made. This analyser differs from other similar ones described in the literature through the fact that pulses are cumulated only as long as the vibrator speed ensures a complete cancelation of the resonance condition. A NIM analyser was also manufactured which allows a qualitative determination of 2-3 iron compounds in a given sample, as well as of the total iron content. Working in geometry transmission and constant velocity regime, this analyser joins the inconstancy of a laboratory Moessbauer spectrometer with the swiftness and simplity of a specialized Moessbauer spectrometer. Analysis of the main factor that affects the qualitative and quantitative cassiterite determinations: sample structural composition, spectrometer calibrating, a.s.o. Determination accuracy is similar to those reported in the literature. Sample structural composition must be smaller than 0.1 mm for the qualitative and quantitative determinations of iron or total iron compounds. Data accuracy is similar to those reported before, but obtained by means of area measurements. As a consequence of the previous results, we have looked for the existence of some new phases in industrial Fe-C and Fe-Si steels or some new compounds appearance in the samples subjected to coroding. (author)

  17. Analysis of Steel Wire Rope Diagnostic Data Applying Multi-Criteria Methods

    Directory of Open Access Journals (Sweden)

    Audrius Čereška

    2018-02-01

    Full Text Available Steel ropes are complex flexible structures used in many technical applications, such as elevators, cable cars, and funicular cabs. Due to the specific design and critical safety requirements, diagnostics of ropes remains an important issue. Broken wire number in the steel ropes is limited by safety standards when they are used in the human lifting and carrying installations. There are some practical issues on loose wires—firstly, it shows end of lifetime of the entire rope, independently of wear, lubrication or wrong winding on the drums or through pulleys; and, secondly, it can stick in the tight pulley—support gaps and cause deterioration of rope structure up to birdcage formations. Normal rope operation should not generate broken wires, so increasing of their number shows a need for rope installation maintenance. This paper presents a methodology of steel rope diagnostics and the results of analysis using multi-criteria analysis methods. The experimental part of the research was performed using an original test bench to detect broken wires on the rope surface by its vibrations. Diagnostics was performed in the range of frequencies from 60 to 560 Hz with a pitch of 50 Hz. The obtained amplitudes of the broken rope wire vibrations, different from the entire rope surface vibration parameters, was the significant outcome. Later analysis of the obtained experimental results revealed the most significant values of the diagnostic parameters. The evaluation of the power of the diagnostics was implemented by using multi-criteria decision-making (MCDM methods. Various decision-making methods are necessary due to unknown efficiencies with respect to the physical phenomena of the evaluated processes. The significance of the methods was evaluated using objective methods from the structure of the presented data. Some of these methods were proposed by authors of this paper. Implementation of MCDM in diagnostic data analysis and definition of the

  18. Application of diagnostic methods and molecular diagnosis of hemoglobin disorders in Khuzestan province of Iran

    Science.gov (United States)

    Fakher, Rahim; Bijan, Kaeikhaei; Taghi, Akbari Mohammad

    2007-01-01

    BACKGROUND: The hemoglobinopathies refer to a diverse group of inherited disorders characterized by a reduced synthesis of one or more globin chains (thalassemias) or the synthesis of structurally abnormal hemoglobin (Hb). The thalassemias often coexist with a variety of structural Hb variants giving rise to complex genotypes and an extremely wide spectrum of clinical and hematological phenotypes. Hematological and biochemical investigations and family studies provide essential clues to the different interactions and are fundamental to DNA diagnostics of the Hb disorders. Although DNA diagnostics have made a major impact on our understanding and detection of the hemoglobinopathies, DNA mutation testing should never be considered a shortcut or the test of first choice in the workup of a hemoglobinopathy. MATERIALS AND METHODS: A careful three-tier approach involving: (1) Full blood count (2) Special hematological tests, followed by (3) DNA mutation analysis, provides the most effective way in which to detect primary gene mutations as well as gene-gene interactions that can influence the overall phenotype. With the exception of a few rare deletions and rearrangements, the molecular lesions causing hemoglobinopathies are all identifiable by PCR-based techniques. Furthermore, each at-risk ethnic group has its own combination of common Hb variants and thalassemia mutations. In Iran, there are many different forms of α and β thalassemia. Increasingly, different Hb variants are being detected and their effects per se or in combination with the thalassemias, provide additional diagnostic challenges. RESULTS: We did step-by-step diagnosis workup in 800 patients with hemoglobinopathies who referred to Research center of Thalassemia and Hemoglobinopathies in Shafa Hospital of Ahwaz Joundishapour University of medical sciences, respectively. We detected 173 patients as iron deficiency anemia (IDA) and 627 individuals as thalassemic patients by use of different indices. We

  19. Radiation dosage of various CT-methods in lung diagnostics

    International Nuclear Information System (INIS)

    Heinz-Peer, G.; Weninger, F.; Nowotny, R.; Herold, C.J.

    1996-01-01

    Introduction of the computed tomography index CTDI and the multiple scan average dose (MSAD) has led to standardization of the dose description in CT examinations. Despite the use of these dose parameters, many different dosages are reported in the literature for different CT methods. In addition, there is still a wide range of radiation dosimetry results reported for conventional CT, helical CT, and HRCT used in chest examinations. The variations in dosage are mainly due to difference in factors affecting the dose, i.e. beam geometry, beam quality, scanner geometry ('generation'), and operating parameters. In addition, CT dosimetry instrumentation and methodology make a contribution to dosages. Recent studies calculating differences in factors affecting dosage and CT dosimetry and using similar operating parameters, show similar results in CT dosimetry for conventional and helical CT. On the other hand, dosages for HRCT were greatly reduced. This was mainly caused by narrow beam collimation and increasing section spacing. (orig.) [de

  20. Rock-Magnetic Method for Post Nuclear Detonation Diagnostics

    Science.gov (United States)

    Englert, J.; Petrosky, J.; Bailey, W.; Watts, D. R.; Tauxe, L.; Heger, A. S.

    2011-12-01

    A magnetic signature characteristic of a Nuclear Electromagnetic Pulse (NEMP) may still be detectable near the sites of atmospheric nuclear tests conducted at what is now the Nevada National Security Site. This signature is due to a secondary magnetization component of the natural remanent magnetization of material containing traces of ferromagnetic particles that have been exposed to a strong pulse of magnetic field. We apply a rock-magnetic method introduced by Verrier et al. (2002), and tested on samples exposed to artificial lightning, to samples of rock and building materials (e.g. bricks, concrete) retrieved from several above ground nuclear test sites. The results of magnetization measurements are compared to NEMP simulations and historic test measurements.

  1. Cost utility analysis of diagnostic method of syphilis

    Directory of Open Access Journals (Sweden)

    Viroj Wiwanitkit

    2008-04-01

    Full Text Available Presently, the diagnosis of syphilis is dependent mainly on serological tests. The most widely used screening tests for syphilis are the VDRL and the rapid plasma reagin (RPR and for confirmation, the fluorescent treponemal antibody (FTA and the treponema pallidum hemagglutination (TPHA tests. The four alternative modes for diagnosis of syphilis can be a VDRL + FTA, b VDRL + TPHA, c RPR + FTA and d RPR + TPHA. Here the author reports an evaluation of cost utility of these tests in medical practice. It is shown that the cost per accurate diagnosis with VDRL + TPH is the least expensive choice. Therefore, this alternative is the best method for serological diagnosis for syphilis, based on medical laboratory economics principles

  2. Critical Review of Diagnostic Methods Used in Chronic Pancreatic Disease

    Directory of Open Access Journals (Sweden)

    Ivan T Beck

    1995-01-01

    Full Text Available This paper provides a balanced assessment of the various pancreatic function tests and imaging techniques used in the differential diagnosis of chronic pancreatic disease. Function tests that study the digestive capacity of the pancreas (fat absorption of dietary lipids, fluorescein- or radiolabelled fats, bentiromide test, etc have high specificity, but very low sensitivity. This is because 90% of pancreas has to be destroyed before steatorrhea or creatorrhea occurs. Tests that directly measure pancreatic bicarbonate and protein secretion (secretin test, etc are more accurate and may detect pancreatic dysfunction even before anatomical changes occur. Measurement of pancreatic enzymes in serum or urine, or the decreased decline of serum amino acids during their incorporation into pancreatic enzymes, are not sufficiently sensitive or specific to help diagnose pancreatic disease. Sensitive and specific tumour markers are not yet available. Thus screening tests are not cost-effective - if they are negative, they do not exclude pancreatic disease; and if positive, they have to be confirmed by more specific tests. Imaging techniques are the most commonly used methods of investigation. The usefulness of abdominal survey films, barium studies, percutaneous transhepatic cholangiography, endoscopic retrograde cholangiopancreatography (ERCP, ultrasonography, computed tomographic scan, magnetic resonance imaging and endoscopic ultrasonography is critically reviewed. Most of the radiological methods can be combined with cytology or biopsy. Histology demonstrating malignancy establishes this diagnosis, but negative biopsies do not exclude malignant tumours. Presently only ERCP and endoscopic ultrasound can diagnose cancers sufficiently early to allow for possible `curative' surgery, and only endoscopic ultrasound is capable to stage tumours for the assessment of resectability.

  3. Mixed-Methods Analysis of Rural Special Educators' Role Stressors, Behavior Management, and Burnout

    Science.gov (United States)

    Garwood, Justin D.; Werts, Margaret G.; Varghese, Cheryl; Gosey, Leanne

    2018-01-01

    The researchers of this study used a mixed-methods approach to understand issues of rural special education teacher burnout. Results of survey responses (n = 64) and follow-up focus group interviews (n = 12) from rural special education teachers indicated several factors contributing to stress and burnout. Teachers noted that lack of clarity in…

  4. A Mixed Methods Survey Research Study of Novice Special Education Teachers: Investigation of Reading Preparedness

    Science.gov (United States)

    Stratton, Mary P.

    2017-01-01

    Novice special education teachers have become an integral part of the public and private school systems throughout Pennsylvania. This mixed-methods research study explored the expertise and preparedness of current novice special education teachers. A combination of an electronic survey questionnaire and phone and face-to-face interviews were…

  5. [Hysteroscopy clinic: diagnostic and therapeutic method in abnormal uterine bleeding].

    Science.gov (United States)

    Alanis Fuentes, José; Obregón Zegarra, Eva Haydee

    2012-12-01

    Abnormal uterine bleeding is a public health problem prevalence exceeded only by abnormal vaginal discharge as a reason for medical consultation. To describe the findings reported by the Hysteroscopy clinic of the Hospital GEA Gonzalez on patients with Abnormal Uterine bleeding diagnosis. Retrospective, transversal, descriptive study. The total 2546 records of those patient that were evaluated by Office Hysteroscopic between January 2007 and December 2008 on the Hysteroscopy Clinic of Hospital Manuel GEA Gonzalez, then we selected the 1482 records of those patients that were sended because of an Abnormal Uterine bleeding condition. We descrive the frequencies of the diagnosis and its interrelation with the age of the patients. We also report the therapeutical interventions during office hysteroscopy. The mean age of the patients was 42.15 +/- 9.30 years (from 12 a 92 years); the age groups of patients that belonged to 40-44 years and 45-49 years are the most frequent patient and they represent the 25% y el 23.3% of the records. The abnormal findings occurred on the 66% de of the patients. Those patients of 65 years old and older do not have any report of normal cavities, all of then have abnormal findings. The leiomyoma (26.9%) and the endometrial polyps (27.3%) were the most frequent findings. The postmenopausal bleeding had a rate of 90.9% abnormal findings and in this group of patients the most frequent diagnosis was atrophic endometrium (32.2%) and polyps (24.3%). Besides that the office hysteroscopy show its therapeutical usefulness because of the 67% and 77.5% of polipectomy perform for endometrial and cervical polyps respectively The office Hysteroscopy is a well tolerated diagnosis and therapeutic method that is useful for any women with abnormal uterine bleeding condition and it is the ideal technique for the examination of abnormal uterine bleeding in postmenopausal women... The office hysteroscopy is a efficient cost-effective and cost-benefic method for

  6. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    Science.gov (United States)

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  7. DEVELOPMENT OF THE DIAGNOSTIC METHOD OF MORAL ORIENTATIONS

    Directory of Open Access Journals (Sweden)

    Irina Sergeevna Slavinskaya

    2015-03-01

    Full Text Available The article outlines the developing and standardization of psychodiagnostics test that measures moral orientations for adolescence. The definition of moral orientations as a matter of diagnosis and the justification of chosen stimuli are provided. Respondents evaluate the degree to which 13 values are expressed in the behavior of seven categories of people (from the «native» to the «enemies». Youthful students from 17 to 21 years (N = 330 were used as a standardization sample. Factorial validity of the scales used was tested by using confirmatory factor analysis (CFA. A hierarchical structure of the test (including the common scale and three subscales is confirmed by the CFA. Cronbach’s alpha indicated a high consistency between separate items of the test, demonstrating high reliability of the test’s scales. Criterion validity of the scales is assessed on the basis of the socio-demographic characteristics of the sample. The convergent and discriminant validity was assessed by establishing close statistical relations with constructs similar in content. The standards for test’s scales are developed. The results testify the adequacy of this method for the diagnosis of youth moral orientations.

  8. Artificial Intelligence: Bayesian versus Heuristic Method for Diagnostic Decision Support.

    Science.gov (United States)

    Elkin, Peter L; Schlegel, Daniel R; Anderson, Michael; Komm, Jordan; Ficheur, Gregoire; Bisson, Leslie

    2018-04-01

    Evoking strength is one of the important contributions of the field of Biomedical Informatics to the discipline of Artificial Intelligence. The University at Buffalo's Orthopedics Department wanted to create an expert system to assist patients with self-diagnosis of knee problems and to thereby facilitate referral to the right orthopedic subspecialist. They had two independent sports medicine physicians review 469 cases. A board-certified orthopedic sports medicine practitioner, L.B., reviewed any disagreements until a gold standard diagnosis was reached. For each case, the patients entered 126 potential answers to 26 questions into a Web interface. These were modeled by an expert sports medicine physician and the answers were reviewed by L.B. For each finding, the clinician specified the sensitivity (term frequency) and both specificity (Sp) and the heuristic evoking strength (ES). Heuristics are methods of reasoning with only partial evidence. An expert system was constructed that reflected the posttest odds of disease-ranked list for each case. We compare the accuracy of using Sp to that of using ES (original model, p  < 0.0008; term importance * disease importance [DItimesTI] model, p  < 0.0001: Wilcoxon ranked sum test). For patient referral assignment, Sp in the DItimesTI model was superior to the use of ES. By the fifth diagnosis, the advantage was lost and so there is no difference between the techniques when serving as a reminder system. Schattauer GmbH Stuttgart.

  9. Modern diagnostic method of microelementosis of school age children

    International Nuclear Information System (INIS)

    Rasulov, S.K.

    2006-01-01

    Full text: Human and animal pathology stipulated by deficiency of vitally important (or 'essential') microelements or their excess, has got its combined name microelementosis [1]. In connection with high biological activity of microelements in organism in different physiologic and pathologic status the quantitative determination of several metals in biomedium of organism is of great importance in the study of microelement metabolism. However, objective and representative data on estimation of school children's provision with microelements are practically absent. The objective of the study was to investigate contents of microelements connected with deficiency of biometals participating in hemopoiesis (Cu, Zn, Co, Mn) in biomedium of the organism of school children in Zarafshan region of the Republic of Uzbekistan. We have applied the method of neutron-activation analysis for determination of microelements (Fe, Zn, Cu, Co, Mn) in hair, whole blood, blood serum, urine, saliva, food-stuff samples and in more than 20 elements of other biomedia, as per designed method in Nuclear Physics Institute, Republic of Uzbekistan [4]. The study was carried out on 245 practically healthy children aged 7-17, 131 boys and 33 girls living in four different areas of Samarkand region. According to the designed method the determination of Mn, Cu was done as follows: samples together with standards were packed in polyethylene container and underwent irradiation in vertical channel of the reactor by neutron flow 5x10 13 neutron cm -2 sec - 1 , (for 15 seconds). The measurement of direct activity was conducted in 2 hours for determining of Cu and Mn. For determining of iron, cobalt, zinc the irradiation test measurement was done within 15 hours one month after irradiation by the corresponding radionuclides. In all measurement of element contents different standards were applied: Intralaboratory data was received by fixing a certain number of elements on ashless filter paper and comparison

  10. Clinical and diagnostic methods for evaluation of sharp foreign body syndrome in buffaloes

    Directory of Open Access Journals (Sweden)

    Nasr-Eldin M. Aref

    2013-06-01

    Full Text Available Aim: The present study was designed to evaluate clinically and under laboratory condition the sharp foreign body syndrome (SFBS in buffaloes with special emphasis on the diagnostic value of radiography, ultrasonography and blood gases and acidbase balance. Materials and Methods: 196 buffaloes with a history of anorexia, reduction of milk production and no response to previous medical treatment were included in the present study. These animals were subjected to clinical and radiographical examinations. Positive cases for SFBS were further evaluated by sonography, hemato-biochemical and blood gas and acid base balance analysis.Results: Out of 196 admitted cases, 49 (25% cases were confirmed as SFBS by clinical and radiographical examination. Positive cases were subsequently divided into two main categories (complicated and non complicated according to radiographical and sonographical findings. SFBS with no complication was diagnosed in 16 cases while 33 cases showed various degrees of complication including reticular adhesion (abdominal and diaphragmatic, n= 23, diaphragmatic hernia (n = 6 and traumatic pericarditis (n = 4. Leukocytosis, hyperprotenemia and increased activity of AST and ALT were of additional values in the diagnosis of SFBS. A consistent finding of primary metabolic alkalosis was recorded in all cases except one with advanced traumatic pericarditis that showed metabolic acidosis. Conclusion: While there is no substitution for clinical examination, using of ultrasonography and radiography simultaneously are essential for proper evaluation and differentiation between various sequelae of SFBS in buffaloes. Radiography is an efficient tool for visualization of metallic foreign body while ultrasonography is an excellent device in assessing fibrinous deposits. Hemato-biochemical and blood gases and acid base balance are of additional values in discriminating between various outcomes of SFBS.

  11. Usability Evaluation Methods for Special Interest Internet Information Services

    Directory of Open Access Journals (Sweden)

    Eva-Maria Schön

    2014-06-01

    Full Text Available The internet provides a wide range of scientific information for different areas of research, used by the related scientific communities. Often the design or architecture of these web pages does not correspond to the mental model of their users. As a result the wanted information is difficult to find. Methods established by Usability Engineering and User Experience can help to increase the appeal of scientific internet information services by analyzing the users’ requirements. This paper describes a procedure to analyze and optimize scientific internet information services that can be accomplished with relatively low effort. It consists of a combination of methods that already have been successfully applied to practice: Personas, usability inspections, Online Questionnaire, Kano model and Web Analytics.

  12. The Increase of Operational Safety of Ships by Improving Diagnostic Methods for Marine Diesel Engine

    Directory of Open Access Journals (Sweden)

    Kazimierz Witkowski

    2017-06-01

    Full Text Available This article shows the importance of the diagnostic improvement methods of marine engines to boost the economy and safety of operation of marine cargo ships. The need to implement effective diagnostic methods is justified by presenting statistical data of marine diesel engines failure and the cost of their operation. Based on the own research has been proven, for the chosen example, that indicator diagrams and analysis of indicated parameters have limited utility in the diagnosis of damages of marine engine, although this is a method commonly used in operational practice. To achieve greater diagnostic effectiveness, when, based on indicator diagrams, are calculated and then the characteristics of heat release is analyzed - net of heat release characteristics and the intensity of the heat release, it was demonstrated. This procedure is particularly effective in the diagnosis of damage of injection system components marine diesel engine.

  13. Recursive least squares method of regression coefficients estimation as a special case of Kalman filter

    Science.gov (United States)

    Borodachev, S. M.

    2016-06-01

    The simple derivation of recursive least squares (RLS) method equations is given as special case of Kalman filter estimation of a constant system state under changing observation conditions. A numerical example illustrates application of RLS to multicollinearity problem.

  14. The study of diagnostic accuracy of chest nodules by using different compression methods

    International Nuclear Information System (INIS)

    Liang Zhigang; Kuncheng, L.I.; Zhang Jinghong; Liu Shuliang

    2005-01-01

    Background: The purpose of this study was to compare the diagnostic accuracy of small nodules in the chest by using different compression methods. Method: Two radiologists with 5 years experience twice interpreted 39 chest images by using lossless and lossy compression methods. The time interval was 3 weeks. Each time the radiologists interpreted one kind of compressed images. The image browser used the Unisight software provided by Atlastiger Company in Shanghai. The interpreting results were analyzed by the ROCKIT software and the ROC curves were painted by Excel 2002. Results: In studies of receiver operating characteristics for scoring the presence or absence of nodules, the images with lossy compression method showed no statistical difference as compared with the images with lossless compression method. Conclusion: The diagnostic accuracy of chest nodules by using the lossless and lossy compression methods had no significant difference, we could use the lossy compression method to transmit and archive the chest images with nodules

  15. Optimization of preparation of skilled wrestlers by perfection of method of the special preparation

    Directory of Open Access Journals (Sweden)

    Ogar' G.O.

    2009-12-01

    Full Text Available The author method of the special physical preparation of skilled fighters is presented. A method carries stage-by-stage character. On the first stage effectively to conduct the accented power training. On the second stage - to perfect explosive force. Tasks of the third stage are perfection of speed force and lactate component of energy supply. On the fourth stage the special is perfected speed-power endurance. The fifth stage coincides with beginning of competition period of macrocycle.

  16. Diagnostic method for photovoltaic systems based on light I-V measurements

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Sera, Dezso; Kerekes, Tamas

    2015-01-01

    , be it external, such as shading or soiling, or degradation or failure of the PV modules and balance-of-system components. This allows for performing preventive and/or reparative maintenance, thus minimizing further losses and costs. This article proposes a complete diagnostic method for detecting shading...... and analysis of the diagnostic parameters and logic was performed based on module level tests on standard crystalline silicon PV modules, and were optimized to detect even small partial shading and increase series-resistance losses. To demonstrate the practical application and operation of this method...

  17. Diagnostics on LALR(k) conflicts based on a method for LR(k) testing

    DEFF Research Database (Denmark)

    Kristensen, Bent Bruun; Madsen, Ole Lehrmann

    1981-01-01

    A user of an LALR(k) parser generator system may have difficulties in understanding how a given LALR(k) conflict is generated. This is especially difficult if the conflict does not correspond to an LR(k) conflict. A practical method for giving informative diagnostics on LALR(k) conflicts is prese......A user of an LALR(k) parser generator system may have difficulties in understanding how a given LALR(k) conflict is generated. This is especially difficult if the conflict does not correspond to an LR(k) conflict. A practical method for giving informative diagnostics on LALR(k) conflicts...

  18. Isothermal multiple displacement amplification: a methodical approach enhancing molecular routine diagnostics of microcarcinomas and small biopsies.

    Science.gov (United States)

    Mairinger, Fabian D; Walter, Robert Fh; Vollbrecht, Claudia; Hager, Thomas; Worm, Karl; Ting, Saskia; Wohlschläger, Jeremias; Zarogoulidis, Paul; Zarogoulidis, Konstantinos; Schmid, Kurt W

    2014-01-01

    Isothermal multiple displacement amplification (IMDA) can be a powerful tool in molecular routine diagnostics for homogeneous and sequence-independent whole-genome amplification of notably small tumor samples, eg, microcarcinomas and biopsies containing a small amount of tumor. Currently, this method is not well established in pathology laboratories. We designed a study to confirm the feasibility and convenience of this method for routine diagnostics with formalin-fixed, paraffin-embedded samples prepared by laser-capture microdissection. A total of 250 μg DNA (concentration 5 μg/μL) was generated by amplification over a period of 8 hours with a material input of approximately 25 cells, approximately equivalent to 175 pg of genomic DNA. In the generated DNA, a representation of all chromosomes could be shown and the presence of elected genes relevant for diagnosis in clinical samples could be proven. Mutational analysis of clinical samples could be performed without any difficulty and showed concordance with earlier diagnostic findings. We established the feasibility and convenience of IMDA for routine diagnostics. We also showed that small amounts of DNA, which were not analyzable with current molecular methods, could be sufficient for a wide field of applications in molecular routine diagnostics when they are preamplified with IMDA.

  19. Cost-Effectiveness Analysis of Helicobacter pylori Diagnostic Methods in Patients with Atrophic Gastritis

    Directory of Open Access Journals (Sweden)

    Fumio Omata

    2017-01-01

    Full Text Available Background. There are several diagnostic methods for Helicobacter pylori (H. pylori infection. A cost-effective analysis is needed to decide on the optimal diagnostic method. The aim of this study was to determine a cost-effective diagnostic method in patients with atrophic gastritis (AG. Methods. A decision-analysis model including seven diagnostic methods was constructed for patients with AG diagnosed by esophagogastroduodenoscopy. Expected values of cost and effectiveness were calculated for each test. Results. If the prevalence of H. pylori in the patients with AG is 85% and CAM-resistant H. pylori is 30%, histology, stool H. pylori antigen (SHPAg, bacterial culture (BC, and urine H. pylori antibody (UHPAb were dominated by serum H. pylori IgG antibody (SHPAb, rapid urease test (RUT, and urea breath test (UBT. Among three undominated methods, the incremental cost-effective ratios (ICER of RUT versus SHPAb and UBT versus RUT were $214 and $1914, respectively. If the prevalence of CAM-sensitive H. pylori was less than 55%, BC was not dominated, but its H. pylori eradication success rate was 0.86. Conclusions. RUT was the most cost-effective at the current prevalence of CAM-resistant H. pylori. BC could not be selected due to its poor effectiveness even if CAM-resistant H. pylori was more than 45%.

  20. An effective method for finding special solutions of nonlinear differential equations with variable coefficients

    International Nuclear Information System (INIS)

    Qin Maochang; Fan Guihong

    2008-01-01

    There are many interesting methods can be utilized to construct special solutions of nonlinear differential equations with constant coefficients. However, most of these methods are not applicable to nonlinear differential equations with variable coefficients. A new method is presented in this Letter, which can be used to find special solutions of nonlinear differential equations with variable coefficients. This method is based on seeking appropriate Bernoulli equation corresponding to the equation studied. Many well-known equations are chosen to illustrate the application of this method

  1. [Special application of matrix-assisted laser desorption ionization time-of-flight mass spectrometry in clinical microbiological diagnostics].

    Science.gov (United States)

    Nagy, Erzsébet; Abrók, Marianna; Bartha, Noémi; Bereczki, László; Juhász, Emese; Kardos, Gábor; Kristóf, Katalin; Miszti, Cecilia; Urbán, Edit

    2014-09-21

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry as a new possibility for rapid identification of bacteria and fungi revolutionized the clinical microbiological diagnostics. It has an extreme importance in the routine microbiological laboratories, as identification of the pathogenic species rapidly will influence antibiotic selection before the final determination of antibiotic resistance of the isolate. The classical methods for identification of bacteria or fungi, based on biochemical tests, are influenced by many environmental factors. The matrix-assisted laser desorption ionization time-of-flight mass spectrometry is a rapid method which is able to identify a great variety of the isolated bacteria and fungi based on the composition of conserved ribosomal proteins. Recently several other applications of the method have also been investigated such as direct identification of pathogens from the positive blood cultures. There are possibilities to identify bacteria from the urine samples in urinary tract infection or from other sterile body fluids. Using selective enrichment broth Salmonella sp from the stool samples can be identified more rapidly, too. The extended spectrum beta-lactamase or carbapenemase production of the isolated bacteria can be also detected by this method helping the antibiotic selection in some cases. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry based methods are suitable to investigate changes in deoxyribonucleic acid or ribonucleic acid, to carry out rapid antibiotic resistance determination or other proteomic analysis. The aim of this paper is to give an overview about present possibilities of using this technique in the clinical microbiological routine procedures.

  2. Are the classic diagnostic methods in mycology still state of the art?

    Science.gov (United States)

    Wiegand, Cornelia; Bauer, Andrea; Brasch, Jochen; Nenoff, Pietro; Schaller, Martin; Mayser, Peter; Hipler, Uta-Christina; Elsner, Peter

    2016-05-01

    The diagnostic workup of cutaneous fungal infections is traditionally based on microscopic KOH preparations as well as culturing of the causative organism from sample material. Another possible option is the detection of fungal elements by dermatohistology. If performed correctly, these methods are generally suitable for the diagnosis of mycoses. However, the advent of personalized medicine and the tasks arising therefrom require new procedures marked by simplicity, specificity, and swiftness. The additional use of DNA-based molecular techniques further enhances sensitivity and diagnostic specificity, and reduces the diagnostic interval to 24-48 hours, compared to weeks required for conventional mycological methods. Given the steady evolution in the field of personalized medicine, simple analytical PCR-based systems are conceivable, which allow for instant diagnosis of dermatophytes in the dermatology office (point-of-care tests). © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  3. Evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia.

    Science.gov (United States)

    Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh

    2015-12-26

    Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.

  4. Isothermal multiple displacement amplification: a methodical approach enhancing molecular routine diagnostics of microcarcinomas and small biopsies

    Directory of Open Access Journals (Sweden)

    Mairinger FD

    2014-08-01

    Full Text Available Fabian D Mairinger,1 Robert FH Walter,2 Claudia Vollbrecht,3 Thomas Hager,1 Karl Worm,1 Saskia Ting,1 Jeremias Wohlschläger,1 Paul Zarogoulidis,4 Konstantinos Zarogoulidis,4 Kurt W Schmid1 1Institute of Pathology, 2Ruhrlandklinik, West German Lung Center, University Hospital Essen, Essen, 3Institute of Pathology, University Hospital Cologne, Cologne, Germany; 4Pulmonary Department, Oncology Unit, G Papanikolaou General Hospital, Aristotle University of Thessaloniki, Thessaloniki, Greece Background and methods: Isothermal multiple displacement amplification (IMDA can be a powerful tool in molecular routine diagnostics for homogeneous and sequence-independent whole-genome amplification of notably small tumor samples, eg, microcarcinomas and biopsies containing a small amount of tumor. Currently, this method is not well established in pathology laboratories. We designed a study to confirm the feasibility and convenience of this method for routine diagnostics with formalin-fixed, paraffin-embedded samples prepared by laser-capture microdissection. Results: A total of 250 µg DNA (concentration 5 µg/µL was generated by amplification over a period of 8 hours with a material input of approximately 25 cells, approximately equivalent to 175 pg of genomic DNA. In the generated DNA, a representation of all chromosomes could be shown and the presence of elected genes relevant for diagnosis in clinical samples could be proven. Mutational analysis of clinical samples could be performed without any difficulty and showed concordance with earlier diagnostic findings. Conclusion: We established the feasibility and convenience of IMDA for routine diagnostics. We also showed that small amounts of DNA, which were not analyzable with current molecular methods, could be sufficient for a wide field of applications in molecular routine diagnostics when they are preamplified with IMDA. Keywords: isothermal multiple displacement amplification, isothermal, whole

  5. Study on Fault Diagnostics of a Turboprop Engine Using Inverse Performance Model and Artificial Intelligent Methods

    Science.gov (United States)

    Kong, Changduk; Lim, Semyeong

    2011-12-01

    Recently, the health monitoring system of major gas path components of gas turbine uses mostly the model based method like the Gas Path Analysis (GPA). This method is to find quantity changes of component performance characteristic parameters such as isentropic efficiency and mass flow parameter by comparing between measured engine performance parameters such as temperatures, pressures, rotational speeds, fuel consumption, etc. and clean engine performance parameters without any engine faults which are calculated by the base engine performance model. Currently, the expert engine diagnostic systems using the artificial intelligent methods such as Neural Networks (NNs), Fuzzy Logic and Genetic Algorithms (GAs) have been studied to improve the model based method. Among them the NNs are mostly used to the engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base if there are large amount of learning data. In addition, it has a very complex structure for finding effectively single type faults or multiple type faults of gas path components. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measured performance data, and proposes a fault diagnostic system using the base engine performance model and the artificial intelligent methods such as Fuzzy logic and Neural Network. The proposed diagnostic system isolates firstly the faulted components using Fuzzy Logic, then quantifies faults of the identified components using the NN leaned by fault learning data base, which are obtained from the developed base performance model. In leaning the NN, the Feed Forward Back Propagation (FFBP) method is used. Finally, it is verified through several test examples that the component faults implanted arbitrarily in the engine are well isolated and quantified by the proposed diagnostic system.

  6. Diagnostic methods and interpretation of the experiments on microtarget compression in the Iskra-4 device

    International Nuclear Information System (INIS)

    Kochemasov, G.G.

    1992-01-01

    Studies on the problem of laser fusion, which is mainly based on experiments conducted in the Iskra-4 device are reviewed. Different approaches to solution of the problem of DT-fuel ignition, methods of diagnostics of characteristics of laser radiation and plasma, occurring on microtarget heating and compression, are considered

  7. Forecasting with quantitative methods the impact of special events in time series

    OpenAIRE

    Nikolopoulos, Konstantinos

    2010-01-01

    Abstract Quantitative methods are very successful for producing baseline forecasts of time series; however these models fail to forecast neither the timing nor the impact of special events such as promotions or strikes. In most of the cases the timing of such events is not known so they are usually referred as shocks (economics) or special events (forecasting). Sometimes the timing of such events is known a priori (i.e. a future promotion); but even then the impact of the forthcom...

  8. Simulation study on unfolding methods for diagnostic X-rays and mixed gamma rays

    International Nuclear Information System (INIS)

    Hashimoto, Makoto; Ohtaka, Masahiko; Ara, Kuniaki; Kanno, Ikuo; Imamura, Ryo; Mikami, Kenta; Nomiya, Seiichiro; Onabe, Hideaki

    2009-01-01

    A photon detector operating in current mode that can sense X-ray energy distribution has been reported. This detector consists of a row of several segment detectors. The energy distribution is derived using an unfolding technique. In this paper, comparisons of the unfolding techniques among error reduction, spectrum surveillance, and neural network methods are discussed through simulation studies on the detection of diagnostic X-rays and gamma rays emitted by a mixture of 137 Cs and 60 Co. For diagnostic X-ray measurement, the spectrum surveillance and neural network methods appeared promising, while the error reduction method yielded poor results. However, in the case of measuring mixtures of gamma rays, the error reduction method was both sufficient and effective. (author)

  9. A Review of Frequency Response Analysis Methods for Power Transformer Diagnostics

    Directory of Open Access Journals (Sweden)

    Saleh Alsuhaibani

    2016-10-01

    Full Text Available Power transformers play a critical role in electric power networks. Such transformers can suffer failures due to multiple stresses and aging. Thus, assessment of condition and diagnostic techniques are of great importance for improving power network reliability and service continuity. Several techniques are available to diagnose the faults within the power transformer. Frequency response analysis (FRA method is a powerful technique for diagnosing transformer winding deformation and several other types of problems that are caused during manufacture, transportation, installation and/or service life. This paper provides a comprehensive review on FRA methods and their applications in diagnostics and fault identification for power transformers. The paper discusses theory and applications of FRA methods as well as various issues and challenges faced in the application of this method.

  10. Place of modern imaging methods and their influence on the diagnostic process

    International Nuclear Information System (INIS)

    Petkov, D.; Lazarova, I.

    1991-01-01

    The main trends in development of the modern imaging diagnostic methods are presented: increasing the specificity of CT, nuclear-magnetic resonance imaging, positron-emission tomography, digital substractional angiography, echography etc. based on modern technical improvements; objective representation of the physiological and biochemical divergencies in particular diseases; interventional radiology; integral application of different methods; improving the sensitivity and specificity of the methods based on developments in pharmacology (new contrast media, parmaceuticals influencing the function of examinated organs, etc.); the possibilities for data compilation and further computerized processing of primary data. Personal experience is reported with the exploitation of these methods in Bulgaria. Attention is also called to the unfavourable impact connected with the too strong technicization of the diagnostic and therapeutic process in a health, deontologic, economical and social respect. 15 refs

  11. Molecular diagnostic methods for invasive fungal disease: the horizon draws nearer?

    Science.gov (United States)

    Halliday, C L; Kidd, S E; Sorrell, T C; Chen, S C-A

    2015-04-01

    Rapid, accurate diagnostic laboratory tests are needed to improve clinical outcomes of invasive fungal disease (IFD). Traditional direct microscopy, culture and histological techniques constitute the 'gold standard' against which newer tests are judged. Molecular diagnostic methods, whether broad-range or fungal-specific, have great potential to enhance sensitivity and speed of IFD diagnosis, but have varying specificities. The use of PCR-based assays, DNA sequencing, and other molecular methods including those incorporating proteomic approaches such as matrix-assisted laser desorption ionisation-time of flight mass spectroscopy (MALDI-TOF MS) have shown promising results. These are used mainly to complement conventional methods since they require standardisation before widespread implementation can be recommended. None are incorporated into diagnostic criteria for defining IFD. Commercial assays may assist standardisation. This review provides an update of molecular-based diagnostic approaches applicable to biological specimens and fungal cultures in microbiology laboratories. We focus on the most common pathogens, Candida and Aspergillus, and the mucormycetes. The position of molecular-based approaches in the detection of azole and echinocandin antifungal resistance is also discussed.

  12. Reflections from the Application of Different Type of Activities: Special Training Methods Course

    Science.gov (United States)

    Karadeniz, Mihriban Hacisalihoglu

    2017-01-01

    The aim of this study is to reveal the benefits gained from "Special Training Methods II" course and the problems prospective mathematics teachers encountered with it. The case study method was used in the study. The participants in the study were 34 prospective mathematics teachers studying at a Primary School Mathematics Education…

  13. Pressurized water reactor monitoring. Study of detection, diagnostic and estimation (least squares and filtering) methods

    International Nuclear Information System (INIS)

    Gillet, M.

    1986-07-01

    This thesis presents a study for the surveillance of the Primary circuit water inventory of a pressurized water reactor. A reference model is developed for the development of an automatic system ensuring detection and real-time diagnostic. The methods to our application are statistical tests and adapted a pattern recognition method. The estimation of the detected anomalies is treated by the least square fit method, and by filtering. A new projected optimization method with superlinear convergence is developed in this framework, and a segmented linearization of the model is introduced, in view of a multiple filtering. 46 refs [fr

  14. Diagnostic technology and an expert system for photovoltaic systems using the learning method

    Energy Technology Data Exchange (ETDEWEB)

    Yagi, Yasuhiro; Kishi, Hitoshi; Hagihara, Ryuzou; Tanaka, Toshiya; Kozuma, Shinichi; Ishida, Takeo; Waki, Masahiro; Tanaka, Makoto; Kiyama, Seiichi [SANYO Electric Co. Ltd., New Materials Research Center, Moriguchi City, Osaka (Japan)

    2003-02-01

    Diagnostic technology for photovoltaic (PV) systems was developed, using the learning method to take each site's conditions into account. This technology employs diagnostic criteria databases to analyze data acquired from the PV systems. These criteria are updated monthly for each site using analyzed data. To check the shadows on the PV modules and pyranometer, the sophisticated verification method was also applied to this technology. After the diagnosis, a basket method provides maintenance advice for the PV systems. Based on the results of precise diagnoses, this expert system offers quick and proper maintenance advice within a few minutes. This technology is highly useful, because it greatly simplifies the servicing and maintenance of PV systems. (Author)

  15. Vibrational methods of the overhead gas-pipelines technological equipment diagnostics

    International Nuclear Information System (INIS)

    Zakhezin, A.M.; Malysheva, T.V.

    2001-01-01

    The diagnostic methods of overhead gas-pipelines of the technical equipment of gas-compressor station are considered in this article by carrying out registration certification documentation. Some faults of overhead technical gas-pipelines have been proposed. This paper is devoted to the diagnostic methods of the whole gas- pipelines and their parts for some faults during expert checking fulfillment and carrying out registration certification documentation. The analysis of all defects allows to determine a 'between-repairs interval', to develop some operations to avoid these faults and to estimate the repair operation quality, to reduce failure probability. As an example of the effectiveness of technical condition service of vibrational methods by expertise fulfillment have been considered for some defects of the overhead pipelines. (author)

  16. A simple method to combine multiple molecular biomarkers for dichotomous diagnostic classification

    Directory of Open Access Journals (Sweden)

    Amin Manik A

    2006-10-01

    Full Text Available Abstract Background In spite of the recognized diagnostic potential of biomarkers, the quest for squelching noise and wringing in information from a given set of biomarkers continues. Here, we suggest a statistical algorithm that – assuming each molecular biomarker to be a diagnostic test – enriches the diagnostic performance of an optimized set of independent biomarkers employing established statistical techniques. We validated the proposed algorithm using several simulation datasets in addition to four publicly available real datasets that compared i subjects having cancer with those without; ii subjects with two different cancers; iii subjects with two different types of one cancer; and iv subjects with same cancer resulting in differential time to metastasis. Results Our algorithm comprises of three steps: estimating the area under the receiver operating characteristic curve for each biomarker, identifying a subset of biomarkers using linear regression and combining the chosen biomarkers using linear discriminant function analysis. Combining these established statistical methods that are available in most statistical packages, we observed that the diagnostic accuracy of our approach was 100%, 99.94%, 96.67% and 93.92% for the real datasets used in the study. These estimates were comparable to or better than the ones previously reported using alternative methods. In a synthetic dataset, we also observed that all the biomarkers chosen by our algorithm were indeed truly differentially expressed. Conclusion The proposed algorithm can be used for accurate diagnosis in the setting of dichotomous classification of disease states.

  17. Cervical vertebral maturation method and mandibular growth peak: a longitudinal study of diagnostic reliability.

    Science.gov (United States)

    Perinetti, Giuseppe; Primozic, Jasmina; Sharma, Bhavna; Cioffi, Iacopo; Contardo, Luca

    2018-03-28

    The capability of the cervical vertebral maturation (CVM) method in the identification of the mandibular growth peak on an individual basis remains undetermined. The diagnostic reliability of the six-stage CVM method in the identification of the mandibular growth peak was thus investigated. From the files of the Oregon and Burlington Growth Studies (data obtained between early 1950s and middle 1970s), 50 subjects (26 females, 24 males) with at least seven annual lateral cephalograms taken from 9 to 16 years were identified. Cervical vertebral maturation was assessed according to the CVM code staging system, and mandibular growth was defined as annual increments in Co-Gn distance. A diagnostic reliability analysis was carried out to establish the capability of the circumpubertal CVM stages 2, 3, and 4 in the identification of the imminent mandibular growth peak. Variable durations of each of the CVM stages 2, 3, and 4 were seen. The overall diagnostic accuracy values for the CVM stages 2, 3, and 4 were 0.70, 0.76, and 0.77, respectively. These low values appeared to be due to false positive cases. Secular trends in conjunction with the use of a discrete staging system. In most of the Burlington Growth Study sample, the lateral head film at age 15 was missing. None of the CVM stages 2, 3, and 4 reached a satisfactorily diagnostic reliability in the identification of imminent mandibular growth peak.

  18. Diagnostic Method of Diabetes Based on Support Vector Machine and Tongue Images

    Directory of Open Access Journals (Sweden)

    Jianfeng Zhang

    2017-01-01

    Full Text Available Objective. The purpose of this research is to develop a diagnostic method of diabetes based on standardized tongue image using support vector machine (SVM. Methods. Tongue images of 296 diabetic subjects and 531 nondiabetic subjects were collected by the TDA-1 digital tongue instrument. Tongue body and tongue coating were separated by the division-merging method and chrominance-threshold method. With extracted color and texture features of the tongue image as input variables, the diagnostic model of diabetes with SVM was trained. After optimizing the combination of SVM kernel parameters and input variables, the influences of the combinations on the model were analyzed. Results. After normalizing parameters of tongue images, the accuracy rate of diabetes predication was increased from 77.83% to 78.77%. The accuracy rate and area under curve (AUC were not reduced after reducing the dimensions of tongue features with principal component analysis (PCA, while substantially saving the training time. During the training for selecting SVM parameters by genetic algorithm (GA, the accuracy rate of cross-validation was grown from 72% or so to 83.06%. Finally, we compare with several state-of-the-art algorithms, and experimental results show that our algorithm has the best predictive accuracy. Conclusions. The diagnostic method of diabetes on the basis of tongue images in Traditional Chinese Medicine (TCM is of great value, indicating the feasibility of digitalized tongue diagnosis.

  19. [Methods of statistical analysis in differential diagnostics of the degree of brain glioma anaplasia during preoperative stage].

    Science.gov (United States)

    Glavatskiĭ, A Ia; Guzhovskaia, N V; Lysenko, S N; Kulik, A V

    2005-12-01

    The authors proposed a possible preoperative diagnostics of the degree of supratentorial brain gliom anaplasia using statistical analysis methods. It relies on a complex examination of 934 patients with I-IV degree anaplasias, which had been treated in the Institute of Neurosurgery from 1990 to 2004. The use of statistical analysis methods for differential diagnostics of the degree of brain gliom anaplasia may optimize a diagnostic algorithm, increase reliability of obtained data and in some cases avoid carrying out irrational operative intrusions. Clinically important signs for the use of statistical analysis methods directed to preoperative diagnostics of brain gliom anaplasia have been defined

  20. [Identification of special quality eggs with NIR spectroscopy technology based on symbol entropy feature extraction method].

    Science.gov (United States)

    Zhao, Yong; Hong, Wen-Xue

    2011-11-01

    Fast, nondestructive and accurate identification of special quality eggs is an urgent problem. The present paper proposed a new feature extraction method based on symbol entropy to identify near infrared spectroscopy of special quality eggs. The authors selected normal eggs, free range eggs, selenium-enriched eggs and zinc-enriched eggs as research objects and measured the near-infrared diffuse reflectance spectra in the range of 12 000-4 000 cm(-1). Raw spectra were symbolically represented with aggregation approximation algorithm and symbolic entropy was extracted as feature vector. An error-correcting output codes multiclass support vector machine classifier was designed to identify the spectrum. Symbolic entropy feature is robust when parameter changed and the highest recognition rate reaches up to 100%. The results show that the identification method of special quality eggs using near-infrared is feasible and the symbol entropy can be used as a new feature extraction method of near-infrared spectra.

  1. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology

    Directory of Open Access Journals (Sweden)

    Udasimath Shivakumarswamy

    2012-01-01

    Full Text Available Background: The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS method. Aims: To compare the morphological features of the CS method with those of the cell block (CB method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. Materials and Methods: The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol-formalin as a fixative agent. Statistical analysis with the ′z test′ was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer′s χ2 test was used to identify the additional yield for malignancy by the CB method. Results: Cellularity and additional yield for malignancy was 15% more by the CB method. Conclusions: The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method.

  2. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology.

    Science.gov (United States)

    Shivakumarswamy, Udasimath; Arakeri, Surekha U; Karigowdar, Mahesh H; Yelikar, Br

    2012-01-01

    The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS) method. To compare the morphological features of the CS method with those of the cell block (CB) method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol-formalin as a fixative agent. Statistical analysis with the 'z test' was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer's χ(2)test was used to identify the additional yield for malignancy by the CB method. Cellularity and additional yield for malignancy was 15% more by the CB method. The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method.

  3. LOGICAL CONDITIONS ANALYSIS METHOD FOR DIAGNOSTIC TEST RESULTS DECODING APPLIED TO COMPETENCE ELEMENTS PROFICIENCY

    Directory of Open Access Journals (Sweden)

    V. I. Freyman

    2015-11-01

    Full Text Available Subject of Research.Representation features of education results for competence-based educational programs are analyzed. Solution importance of decoding and proficiency estimation for elements and components of discipline parts of competences is shown. The purpose and objectives of research are formulated. Methods. The paper deals with methods of mathematical logic, Boolean algebra, and parametrical analysis of complex diagnostic test results, that controls proficiency of some discipline competence elements. Results. The method of logical conditions analysis is created. It will give the possibility to formulate logical conditions for proficiency determination of each discipline competence element, controlled by complex diagnostic test. Normalized test result is divided into noncrossing zones; a logical condition about controlled elements proficiency is formulated for each of them. Summarized characteristics for test result zones are imposed. An example of logical conditions forming for diagnostic test with preset features is provided. Practical Relevance. The proposed method of logical conditions analysis is applied in the decoding algorithm of proficiency test diagnosis for discipline competence elements. It will give the possibility to automate the search procedure for elements with insufficient proficiency, and is also usable for estimation of education results of a discipline or a component of competence-based educational program.

  4. Current status and future perspectives on molecular and serological methods in diagnostic mycology.

    Science.gov (United States)

    Lau, Anna; Chen, Sharon; Sleiman, Sue; Sorrell, Tania

    2009-11-01

    Invasive fungal infections are an important cause of infectious morbidity. Nonculture-based methods are increasingly used for rapid, accurate diagnosis to improve patient outcomes. New and existing DNA amplification platforms have high sensitivity and specificity for direct detection and identification of fungi in clinical specimens. Since laboratories are increasingly reliant on DNA sequencing for fungal identification, measures to improve sequence interpretation should support validation of reference isolates and quality control in public gene repositories. Novel technologies (e.g., isothermal and PNA FISH methods), platforms enabling high-throughput analyses (e.g., DNA microarrays and Luminex xMAP) and/or commercial PCR assays warrant further evaluation for routine diagnostic use. Notwithstanding the advantages of molecular tests, serological assays remain clinically useful for patient management. The serum Aspergillus galactomannan test has been incorporated into diagnostic algorithms of invasive aspergillosis. Both the galactomannan and the serum beta-D-glucan test have value for diagnosing infection and monitoring therapeutic response.

  5. DIFFERENTIAL DIAGNOSTICS MODEL RESEARCH BY MEANS OF THE POTENTIAL FUNCTIONS METHOD FOR NEUROLOGY DISEASES CLASSIFICATION

    Directory of Open Access Journals (Sweden)

    V. Z. Stetsyuk

    2016-10-01

    Full Text Available Informatization in medicine offers a lot of opportunities to enhance quality of medical support, accuracy of diagnosis and provides the use of accumulated experience. Modern program systems are utilized now as additional tools to get appropriate advice. This article offers the way to provide help for neurology department doctor of NCSH «OKHMATDYT» during diagnosis determining. It was decided to design the program system for this purpose based on differential diagnostic model. The key problems in differential diagnosis are symptoms similarity between each other in one disease group and the absence of key symptom. Therefore the differential diagnostic model is needed. It is constructed using the potential function method in characteristics space. This characteristics space is formed by 100-200 points - patients with their symptoms. The main feature of this method here is that the decision function is building during recognition step united with learning that became possible with the help of modern powerful computers.

  6. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method

    International Nuclear Information System (INIS)

    Tang Qi; Song Zifeng; Chen Jiabin; Zhan Xiayu

    2013-01-01

    Ion temperature of implosion hotspot is a very important parameter for inertial confinement fusion. It reflects the energy level of the hotspot, and it is very sensitive to implosion symmetry and implosion speed. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method were described. A neutron TOF spectrometer was developed using a ultrafast plastic scintillator as the neutron detector. Time response of the spectrometer has 1.1 ns FWHM and 0.5 ns rising time. TOF spectrum resolving method based on deconvolution and low pass filter was illuminated. Implosion hotspot ion temperature in low neutron yield and low ion temperature condition at Shenguang-Ⅲ facility was acquired using the diagnostic techniques. (authors)

  7. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 18

    International Nuclear Information System (INIS)

    Pazsit, Imre; Nam, Tran Hoai; Dykin, Victor; Jonsson, Anders

    2013-01-01

    This report constitutes Stage 18 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The objective of the research program is to contribute to the strategic research goal of competence and research capacity by building up competence within the Department of Nuclear Engineering at Chalmers University of Technology, regarding reactor physics, reactor dynamics and noise diagnostics. The purpose is also to contribute to the research goal of giving a basis for SSM's supervision by developing methods for identification and localization of perturbations in reactor cores. Results up to Stage 17 were reported in SKI and SSM reports, as listed in the report's summary

  8. A qualitative model construction method of nuclear power plants for effective diagnostic knowledge generation

    International Nuclear Information System (INIS)

    Yoshikawa, Shinji; Endou, Akira; Kitamura, Yoshinobu; Sasajima, Munehiko; Ikeda, Mitsuru; Mizoguchi, Riichiro.

    1994-01-01

    This paper discusses a method to construct a qualitative model of a nuclear power plant, in order to generate effective diagnostic knowledge. The proposed method is to prepare deep knowledge to be provided to a knowledge compiler based upon qualitative reasoning (QR). Necessity of knowledge compilation for nuclear plant diagnosis will be explained first, and conventionally-experienced problems in qualitative reasoning and a proposed method to overcome this problem is shown next, then a sample procedure to build a qualitative nuclear plant model is demonstrated. (author)

  9. Plant diagnostics in power stations

    International Nuclear Information System (INIS)

    Sturm, A.; Doering, D.

    1985-01-01

    The method of noise diagnostics is dealt with as a part of plant diagnostics in nuclear power stations. The following special applications are presented: (1) The modular noise diagnostics system is used for monitoring primary coolant circuits and detecting abnormal processes due to mechanical vibrations, loose parts or leaks. (2) The diagnostics of machines and plants with antifriction bearings is based on bearing vibration measurements. (3) The measurement of the friction moment by means of acoustic emission analysis is used for evaluating the operational state of slide bearings

  10. Application of the spectral-correlation method for diagnostics of cellulose paper

    Science.gov (United States)

    Kiesewetter, D.; Malyugin, V.; Reznik, A.; Yudin, A.; Zhuravleva, N.

    2017-11-01

    The spectral-correlation method was described for diagnostics of optically inhomogeneous biological objects and materials of natural origin. The interrelation between parameters of the studied objects and parameters of the cross correlation function of speckle patterns produced by scattering of coherent light at different wavelengths is shown for thickness, optical density and internal structure of the material. A detailed study was performed for cellulose electric insulating paper with different parameters.

  11. Bayesian and maximum entropy methods for fusion diagnostic measurements with compact neutron spectrometers

    International Nuclear Information System (INIS)

    Reginatto, Marcel; Zimbal, Andreas

    2008-01-01

    In applications of neutron spectrometry to fusion diagnostics, it is advantageous to use methods of data analysis which can extract information from the spectrum that is directly related to the parameters of interest that describe the plasma. We present here methods of data analysis which were developed with this goal in mind, and which were applied to spectrometric measurements made with an organic liquid scintillation detector (type NE213). In our approach, we combine Bayesian parameter estimation methods and unfolding methods based on the maximum entropy principle. This two-step method allows us to optimize the analysis of the data depending on the type of information that we want to extract from the measurements. To illustrate these methods, we analyze neutron measurements made at the PTB accelerator under controlled conditions, using accelerator-produced neutron beams. Although the methods have been chosen with a specific application in mind, they are general enough to be useful for many other types of measurements

  12. Competence and lastingness in specialized clinical laboratories: technical report about requirements concerning quality of users competence and used processes in immunochemical diagnostic procedures using isotopic and non-isotopic tracer technologies

    International Nuclear Information System (INIS)

    Wiegel, B.

    2005-01-01

    From the citizens view this technical report about immunochemical diagnostic procedures using radioactive and nonradioactive tracer technologies describes the requirements in special laboratory diagnostics concerning competency and process control. Governmental or administrational obligations of inspecting both skill and sites to guarantee patients security are pointed out. (orig.)

  13. Application of contemporary imaging methods in diagnostics of mild cognitive impairment

    International Nuclear Information System (INIS)

    Walecki, J.; Pawlowska-Detko, A.; Ignaciuk, K.; Gabryelewicz, T.; Barcikowska, M.

    2006-01-01

    Mild cognitive impairment (MCI) is defined as a heterogeneous clinical syndrome associated with high risk of the development of dementia, especially Alzheimer disease (AD). Owing to the recent advances in understanding of the molecular phenomena underlying AD there is a chance of introducing effective therapy for this disease in the near future. Therefore, improvement of early diagnostics methods and finding the markers of AD progression, especially in the high risk population of patients with MCI becomes a crucial issue. From the clinical point of view, great expectations are associated with neuroradiologic methods, which are hoped to make it possible to find the markers of conversion from MCI to dementia and the markers of dementia progression in subjects at risk of the development of AD. Growing interest in the problem of MCI diagnostics, reflected in numerous medical publications that have appeared during the recent few years, has prompted the authors to review and summarize the current knowledge concerning the application of modern neuroradiologic methods in the diagnostics of subjects with MCI. (author)

  14. Integration of PET/CT in Current Diagnostic and Response Evaluation Methods in Patients with Tuberculosis

    International Nuclear Information System (INIS)

    Oezmen, Oelem; Goekcek, Atila; Tatci, Ebru; Biner, Inci; Akkalyoncu, Behiye

    2014-01-01

    Tuberculosis is a systemic disease that still affects many people. While pleural involvement is frequently observed in extrapulmonary tuberculosis, multiple skeletal system and articular involvements are quite rare. FDG PET imaging could be a promising diagnostic and treatment monitoring method, especially in complicated cases and if the other methods are inadequate. In this case study, we report a patient who was admitted with suspected malignancy and then diagnosed with tuberculosis pleuritis, lymphadenitis, spondylodiscitis, and sacroiliitis with specific symptoms; the response to anti-tuberculosis therapy was shown using FDG PET/CT

  15. Using method of geotechnical diagnostics for oil and gas pipelines on the base of aerospace monitoring

    International Nuclear Information System (INIS)

    Shirinzade, A.; Gasanov, Kh.; Ragimov, R.; Timofeev, A.

    2008-01-01

    In the paper o the base of aerospatial images of decoding it is studied the problems of using the method of geotechnical diagnostics (GTD) for magistral pipelines. This technique is used for discovering potentially dangerous sections. It has been shown that the processes in geotechnical system have pecular properties on the earth surface which may be identified in terms of aerospace monitoring. Studing these properties one can conclude about state of the system as whole. It is described example of using the GTD method for practical evaluation of magistral pipeline

  16. Methods to determine fast-ion distribution functions from multi-diagnostic measurements

    DEFF Research Database (Denmark)

    Jacobsen, Asger Schou; Salewski, Mirko

    -ion diagnostic views, it is possible to infer the distribution function using a tomography approach. Several inversion methods for solving this tomography problem in velocity space are implemented and compared. It is found that the best quality it obtained when using inversion methods which penalise steep......Understanding the behaviour of fast ions in a fusion plasma is very important, since the fusion-born alpha particles are expected to be the main source of heating in a fusion power plant. Preferably, the entire fast-ion velocity-space distribution function would be measured. However, no fast...

  17. Integration of PET/CT in Current Diagnostic and Response Evaluation Methods in Patients with Tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Oezmen, Oelem; Goekcek, Atila; Tatci, Ebru; Biner, Inci; Akkalyoncu, Behiye [Atatuerk Chest Diseases and Thoracic Surgery Training and Research Hospital, Ankara (Turkmenistan)

    2014-03-15

    Tuberculosis is a systemic disease that still affects many people. While pleural involvement is frequently observed in extrapulmonary tuberculosis, multiple skeletal system and articular involvements are quite rare. FDG PET imaging could be a promising diagnostic and treatment monitoring method, especially in complicated cases and if the other methods are inadequate. In this case study, we report a patient who was admitted with suspected malignancy and then diagnosed with tuberculosis pleuritis, lymphadenitis, spondylodiscitis, and sacroiliitis with specific symptoms; the response to anti-tuberculosis therapy was shown using FDG PET/CT.

  18. evelopment of a boiling water reactor fault diagnostic system with a signed directed graph method

    International Nuclear Information System (INIS)

    Chen, M.; Yu, C.C.; Liou, C.T.; Liao, L.Y.

    1990-01-01

    The fault diagnostic system for a nuclear power reactor is expected to be a useful decision support system for the operators during transients and accident conditions. A considerable research effort has been devoted to the development of automated fault diagnostic systems. One major approach, which has been widely used in chemical engineering, is to identify the possible causes of process disturbance using a logic-oriented method called signed directed graph (SDG). A knowledge based system was developed with the rules derived from the SDG representation. The SDG for the Chinshan nuclear power plant, which is a typical boiling water reactor, is established. The personal consultant system is used as the expert system development tool in this paper

  19. Methodical Approach to Diagnostics of Efficiency of Production Economic Activity of an Enterprise

    Directory of Open Access Journals (Sweden)

    Zhukov Andrii V.

    2014-03-01

    Full Text Available The article offers developments of a methodical approach to diagnostics of efficiency of production economic activity of an enterprise, which, unlike the existing ones, is realised through the following stages: analysis of the enterprise external environment; analysis of the enterprise internal environment; identification of components of efficiency of production economic activity for carrying out complex diagnostics by the following directions: efficiency of subsystems of the enterprise production economic activity, efficiency of use of separate types of resources and socio-economic efficiency; scorecard formation; study of tendencies of change of indicators; identification of cause-effect dependencies between the main components of efficiency for diagnosing reasons of its level; diagnosing deviations of indicator values from their optimal values; development of a managerial decision on preserving and increasing efficiency of production economic activity of the enterprise.

  20. Diagnostic accuracy of medical imagings and an integrated statistical approach to diagnosis. With special attention to hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kawahira, Kosaburo

    1985-05-01

    Twenty-two patients with hepatocellular carcinoma and 36 without were clinically studied using angiography, computed tomography (CT), ultrasound (US) and Tc-99m phytate scintigraphy (RI). Diagnoses were confirmed by biopsy, surgery or autopsy, in all 58 patients. The judgement of multi-readers was obtained, independently. For a diagnosis of hepatocellular carcinoma, angiography was the most useful. Sensitivity, specificity and accuracy of this modality were 0.67, 0.85 and 0.78, respectively. Specificity and accuracy of US were 0.84 and 0.67, respectively, thereby US was the second best modality. CT was more useful than than RI for a diagnosis of hepatocellular carcinoma, in this series. Diagnostic accuracy of the 4 modalities in the diagnosis of liver mass were also discussed. To integrate these 4 images for a diagnosis of hepatocellular carcinoma, a multivariate analysis was made. The diagnostic accuracy of the system was considerably higher than that of any single modality.

  1. A simple, scalable and low-cost method to generate thermal diagnostics of a domestic building

    International Nuclear Information System (INIS)

    Papafragkou, Anastasios; Ghosh, Siddhartha; James, Patrick A.B.; Rogers, Alex; Bahaj, AbuBakr S.

    2014-01-01

    Highlights: • Our diagnostic method uses a single field measurement from a temperature logger. • Building technical performance and occupant behaviour are addressed simultaneously. • Our algorithm learns a thermal model of a home and diagnoses the heating system. • We propose a novel clustering approach to decouple user behaviour from technical performance. • Our diagnostic confidence is enhanced using a large scale deployment. - Abstract: Traditional approaches to understand the problem of the energy performance in the domestic sector include on-site surveys by energy assessors and the installation of complex home energy monitoring systems. The time and money that needs to be invested by the occupants and the form of feedback generated by these approaches often makes them unattractive to householders. This paper demonstrates a simple, low cost method that generates thermal diagnostics for dwellings, measuring only one field dataset; internal temperature over a period of 1 week. A thermal model, which is essentially a learning algorithm, generates a set of thermal diagnostics about the primary heating system, the occupants’ preferences and the impact of certain interventions, such as lowering the thermostat set-point. A simple clustering approach is also proposed to categorise homes according to their building fabric thermal performance and occupants’ energy efficiency with respect to ventilation. The advantage of this clustering approach is that the occupants receive tailored advice on certain actions that if taken will improve the overall thermal performance of a dwelling. Due to the method’s low cost and simplicity it could facilitate government initiatives, such as the ‘Green Deal’ in the UK

  2. Runge–Kutta type methods with special properties for the numerical integration of ordinary differential equations

    International Nuclear Information System (INIS)

    Kalogiratou, Z.; Monovasilis, Th.; Psihoyios, G.; Simos, T.E.

    2014-01-01

    In this work we review single step methods of the Runge–Kutta type with special properties. Among them are methods specially tuned to integrate problems that exhibit a pronounced oscillatory character and such problems arise often in celestial mechanics and quantum mechanics. Symplectic methods, exponentially and trigonometrically fitted methods, minimum phase-lag and phase-fitted methods are presented. These are Runge–Kutta, Runge–Kutta–Nyström and Partitioned Runge–Kutta methods. The theory of constructing such methods is given as well as several specific methods. In order to present the performance of the methods we have tested 58 methods from all categories. We consider the two dimensional harmonic oscillator, the two body problem, the pendulum problem and the orbital problem studied by Stiefel and Bettis. Also we have tested the methods on the computation of the eigenvalues of the one dimensional time independent Schrödinger equation with the harmonic oscillator, the doubly anharmonic oscillator and the exponential potentials

  3. Noninvasive diagnostic methods for perceptual and motor disabilities in children with cerebral palsy

    Directory of Open Access Journals (Sweden)

    Renee Lampe

    2009-09-01

    Full Text Available The field of neuroorthopedics centers on chronic diseases demanding close clinical monitoring. We shall use several examples to show how the various noninvasive diagnostic instruments can be used to obtain insight into the central nervous system as well as into the musculoskeletal system and its morphology. The choice of the most appropriate method depends on the problem; that is, whether the method is to be applied for clinical use or for basic research. In this report we introduce various technical examination methods that are being used successfully in the fields of pediatrics, orthopedics, and neurology. The major examination instrument in pediatric diagnostics is sonography, which is being used in this report as a research instrument for the biomechanics of the musculoskeletal system, but which also gives insight into neurofunctional sequences. In orthopedics, pedography is used for diagnosing deformities of the feet. In neuroorthopedics for children pedography acts as a functional monitor for apraxia and thus allows, for example, a classification of the degree of neurological malfunctions in the lower extremities. The 3D bodyscan is used to minimize x-raying in patients with neurogenic scoliosis. This report introduces examples of the application of MRI and fMRI for basic research. The biometric measuring methods introduced provide precise data in the areas of diagnostics and monitoring and are highly valuable for further neuroorthopedic basic research. In future we expect the ever-evolving technical measuring methods to enable a deeper understanding of the primary neurological causes of and the implications for patients with cerebral palsy and other neuroorthopedic conditions. This may allow the development of new forms of therapy not necessarily predictable today.

  4. Diagnostic accuracy of three screening questions (3Q/TMD) in relation to the DC/TMD in a specialized orofacial pain clinic.

    Science.gov (United States)

    Lövgren, Anna; Parvaneh, Hasti; Lobbezoo, Frank; Häggman-Henrikson, Birgitta; Wänman, Anders; Visscher, Corine Mirjam

    2018-02-15

    To determine the diagnostic accuracy of three screening questions (3Q/TMD) in relation to the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD), in a specialized clinic. Consecutive patients, >18 years, referred with a possible TMD complaint to the Orofacial Pain and Dysfunction clinic, Academic Centre for Dentistry Amsterdam, the Netherlands, were included in the study. All patients (n = 449; mean age 44 years; 72% females), answered the 3Q/TMD and the DC/TMD questionnaire before a DC/TMD examination. The 3Q/TMD constitutes of two questions on weekly pain from the jaw, face and temple region (Q1), and on function (Q2), and one function-related question on weekly catching and/or locking of the jaw (Q3). Q1 and Q2 were evaluated in relation to a DC/TMD pain diagnosis and Q3 in relation to a subgroup of DC/TMD intra-articular diagnosis, referred to as the reference standard. In total, 44% of patients received a pain-related DC/TMD diagnosis and 33% an intra-articular reference DC/TMD diagnosis. Sensitivity for the two pain screening questions was high (0.83-0.94), whereas specificity was low (0.41-0.55). For the function-related question, sensitivity was low (0.48), whereas specificity was high (0.96). In a specialized pain clinic, the two pain questions (Q1, Q2) are positive in most patients with pain-related TMD. Therefore, in case of a positive response, further diagnostic procedures for TMD pain are warranted. For the functional screening question (Q3), a positive response is indicative for an intra-articular DC/TMD diagnosis, while in case of a negative outcome, an intra-articular TMD might still be present.

  5. Advanced Optical Diagnostic Methods for Describing Fuel Injection and Combustion Flowfield Phenomena

    Science.gov (United States)

    Locke, Randy J.; Hicks, Yolanda R.; Anderson, Robert C.

    2004-01-01

    resulted from this feedback. Alternate diagnostic methods are constantly being evaluated as to their suitability as a diagnostic tool in these environments. A new method currently under examination is background oriented Schlieren (BOS) for examining the fuel/air mixing processes. While ratioing the Stokes and anti-Stokes nitrogen lines obtained from spontaneous Raman is being refined for temperature measurement. While the primary focus of the GRC diagnostic work remains optical species measurement and flow stream characterization, an increased emphasis has been placed on our involvement in flame code validation efforts. A functional combustor code should shorten and streamline future combustor design. Quantitative measurements of flow parameters such as temperature, species concentration, drop size and velocity using such methods as Raman and phase Doppler anemometry will provide data necessary in this effort.

  6. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection

    Directory of Open Access Journals (Sweden)

    Han Yih Lau

    2017-12-01

    Full Text Available Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail.

  7. An affordable and easy-to-use diagnostic method for keratoconus detection using a smartphone

    Science.gov (United States)

    Askarian, Behnam; Tabei, Fatemehsadat; Askarian, Amin; Chong, Jo Woon

    2018-02-01

    Recently, smartphones are used for disease diagnosis and healthcare. In this paper, we propose a novel affordable diagnostic method of detecting keratoconus using a smartphone. Keratoconus is usually detected in clinics with ophthalmic devices, which are large, expensive and not portable, and need to be operated by trained technicians. However, our proposed smartphone-based eye disease detection method is small, affordable, portable, and it can be operated by patients in a convenient way. The results show that the proposed keratoconus detection method detects severe, advanced, and moderate keratoconus with accuracies of 93%, 86%, 67%, respectively. Due to its convenience with these accuracies, the proposed keratoconus detection method is expected to be applied in detecting keratoconus at an earlier stage in an affordable way.

  8. Pressurized water reactor monitoring. Study of detection, diagnostic and estimation methods (least error squares and filtering)

    International Nuclear Information System (INIS)

    Gillet, M.

    1986-07-01

    This thesis presents a study for the surveillance of the ''primary coolant circuit inventory monitoring'' of a pressurized water reactor. A reference model is developed in view of an automatic system ensuring detection and diagnostic in real time. The methods used for the present application are statistical tests and a method related to pattern recognition. The estimation of failures detected, difficult owing to the non-linearity of the problem, is treated by the least error squares method of the predictor or corrector type, and by filtering. It is in this frame that a new optimized method with superlinear convergence is developed, and that a segmented linearization of the model is introduced, in view of a multiple filtering [fr

  9. Budd-Chiari syndrome and secondary nodular regenerative hyperplasia of the liver. Case report with special reference to diagnostic imaging

    International Nuclear Information System (INIS)

    Mutze, A.; Rueckert, R.; Rudolph, B.; Paris, S.; Podrabski, P.

    1993-01-01

    Nodular regenerative hyperplasia is a benign epithelial proliferation of the liver with unknown etiology. We observed a female patient with Budd-Chiari syndrome and secondary nodular regenerative hyperplasia of the liver over a period of five years. Patient history, diagnostic imaging (sonography, CT, MR imaging, angiography), and clinical course are demonstrated along with results of macroscopic and microscopic studies of explanted liver prior to liver transplantation. The patient presented with various predisposing factors in combination that favour the development of nodular regenerative hyperplasia. (orig.) [de

  10. Introduction to the JPA special issue: Can the Psychodynamic Diagnostic Manual put the complex person back at the center-stage of personality assessment?

    Science.gov (United States)

    Huprich, Steven K; Meyer, Gregory J

    2011-03-01

    We briefly introduce this special issue, which focuses both on the Psychodynamic Diagnostic Manual (PDM) and the practice of idiographic, depth-oriented personality assessment. The 7 articles in this issue are diverse in scope but all address these 2 important topics. To set the stage, the special issue opens with a description of the history behind, the purposes of, and the steps taken to develop the PDM, and the next article provides a compelling illustration of depth-oriented personality assessment in the context of a long-term course of psychodynamic treatment. The third and fourth articles describe how the PDM model fosters attention to dynamic processes, not just overt symptoms, and they articulate the challenges and benefits of integrating this model into both the revitalized practice of assessment and diagnosis and the research avenues that will evaluate its validity and utility. The fifth article provides a broad overview of interesting experimental research on implicit processes from personality, social, and cognitive psychology, with implications for understanding and assessing dynamic processes. The sixth article illustrates how a PDM-based assessment of an adolescent boy helpfully contributed to his psychodynamic therapy. Finally, the issue closes with an illuminating article describing a PDM-based training model for the graduated development of assessment and diagnosis skills in a doctoral program. Overall, this special issue helps show how the PDM can invigorate multimethod personality assessment by placing the complex idiographic understanding of a person at the center-stage in the assessment process.

  11. Study of special challenges for NDT-methods on nuclear structures

    Energy Technology Data Exchange (ETDEWEB)

    Maack, Stefan; Wiggenhauser, Herbert [BAM Bundesanstalt fuer Materialforschung und -pruefung, Berlin (Germany); Thunell, Bjoern [Scanscot Technology AB, Lund (Sweden)

    2015-07-01

    The special design of buildings, constructed for nuclear power plants is a particular challenge for the nondestructive testing in the building industry. In particular the major component thicknesses, the degree of reinforcement and surface coating systems make the application of NDT methods difficult. The studies first steps were undertaken to determine to which extent established applications of these techniques are useable in the field of infrastructure buildings. Methods have been evaluated that are already state of the art. So for example the ground penetrating radar was used for locating metallic mounting parts. Furthermore, the low-lying internal structure of the containment was investigated with the ultrasonic method.

  12. A Simple Method for Making Diagnostic Casts for Dental Implants Using Acrylic Abutments

    Directory of Open Access Journals (Sweden)

    H. Siadat

    2007-06-01

    Full Text Available The use of multiple implants in the same jaw requires a detailed knowledge of abutment angulation. The position and angulation of the abutments play an important role in treatment planning and fabrication of the custom tray. Therefore diagnostic casts thatcontain cover screws may cause problems during implant therapy.The current article describes a technique for making a preliminary cast with acrylic custom abutments in order to help the clinician select an appropriate impression technique and evaluate the location and angulations of the implant bodies. This method can also aid the technician to provide adequate and proper space for the fabrication of an open custom tray.

  13. White-Nose Syndrome Disease Severity and a Comparison of Diagnostic Methods.

    Science.gov (United States)

    McGuire, Liam P; Turner, James M; Warnecke, Lisa; McGregor, Glenna; Bollinger, Trent K; Misra, Vikram; Foster, Jeffrey T; Frick, Winifred F; Kilpatrick, A Marm; Willis, Craig K R

    2016-03-01

    White-nose syndrome is caused by the fungus Pseudogymnoascus destructans and has killed millions of hibernating bats in North America but the pathophysiology of the disease remains poorly understood. Our objectives were to (1) assess non-destructive diagnostic methods for P. destructans infection compared to histopathology, the current gold-standard, and (2) to evaluate potential metrics of disease severity. We used data from three captive inoculation experiments involving 181 little brown bats (Myotis lucifugus) to compare histopathology, quantitative PCR (qPCR), and ultraviolet fluorescence as diagnostic methods of P. destructans infection. To assess disease severity, we considered two histology metrics (wing area with fungal hyphae, area of dermal necrosis), P. destructans fungal load (qPCR), ultraviolet fluorescence, and blood chemistry (hematocrit, sodium, glucose, pCO2, and bicarbonate). Quantitative PCR was most effective for early detection of P. destructans, while all three methods were comparable in severe infections. Correlations among hyphae and necrosis scores, qPCR, ultraviolet fluorescence, blood chemistry, and hibernation duration indicate a multi-stage pattern of disease. Disruptions of homeostasis occurred rapidly in late hibernation. Our results provide valuable information about the use of non-destructive techniques for monitoring, and provide novel insight into the pathophysiology of white-nose syndrome, with implications for developing and implementing potential mitigation strategies.

  14. Multimodal nonlinear microscopy: A powerful label-free method for supporting standard diagnostics on biological tissues

    Directory of Open Access Journals (Sweden)

    Riccardo Cicchi

    2014-09-01

    Full Text Available The large use of nonlinear laser scanning microscopy in the past decade paved the way for potential clinical application of this imaging technique. Modern nonlinear microscopy techniques offer promising label-free solutions to improve diagnostic performances on tissues. In particular, the combination of multiple nonlinear imaging techniques in the same microscope allows integrating morphological with functional information in a morpho-functional scheme. Such approach provides a high-resolution label-free alternative to both histological and immunohistochemical examination of tissues and is becoming increasingly popular among the clinical community. Nevertheless, several technical improvements, including automatic scanning and image analysis, are required before the technique represents a standard diagnostic method. In this review paper, we highlight the capabilities of multimodal nonlinear microscopy for tissue imaging, by providing various examples on colon, arterial and skin tissues. The comparison between images acquired using multimodal nonlinear microscopy and histology shows a good agreement between the two methods. The results demonstrate that multimodal nonlinear microscopy is a powerful label-free alternative to standard histopathological methods and has the potential to find a stable place in the clinical setting in the near future.

  15. Polychromatic holographic plasma diagnostics

    International Nuclear Information System (INIS)

    Zhiglinskij, A.G.; Morozov, A.O.

    1992-01-01

    Review of holographic interferometry properties is performed and advantages of this method by plasma diagnostics are indicated. Main results obtained by the method of holographic interferometry in studies of various-type plasmas are considered. Special attention is paid to multiwave plasma diagnostics, the necessity of which is related as a rule to multicomponent composition of plasma. The eight laser and gas-discharge sources and holographic schemes, which make it possible to realize plasma polychromatic and holographic interferometry, are considered. The advantages of the method are demonstrated by examples of polychromatic holographic diagnostics of arc discharge and discharge in a hollow cathode. Review of theoretical works determining the applicability area of resonance polychromatic interferometry is carried out

  16. Program specialization

    CERN Document Server

    Marlet, Renaud

    2013-01-01

    This book presents the principles and techniques of program specialization - a general method to make programs faster (and possibly smaller) when some inputs can be known in advance. As an illustration, it describes the architecture of Tempo, an offline program specializer for C that can also specialize code at runtime, and provides figures for concrete applications in various domains. Technical details address issues related to program analysis precision, value reification, incomplete program specialization, strategies to exploit specialized program, incremental specialization, and data speci

  17. Minimal invasive stabilization of osteoporotic vertebral compression fractures. Methods and preinterventional diagnostics

    International Nuclear Information System (INIS)

    Grohs, J.G.; Krepler, P.

    2004-01-01

    Minimal invasive stabilizations represent a new alternative for the treatment of osteoporotic compression fractures. Vertebroplasty and balloon kyphoplasty are two methods to enhance the strength of osteoporotic vertebral bodies by the means of cement application. Vertebroplasty is the older and technically easier method. The balloon kyphoplasty is the newer and more expensive method which does not only improve pain but also restores the sagittal profile of the spine. By balloon kyphoplasty the height of 101 fractured vertebral bodies could be increased up to 90% and the wedge decreased from 12 to 7 degrees. Pain was reduced from 7,2 to 2,5 points. The Oswestry disability index decreased from 60 to 26 points. This effects persisted over a period of two years. Cement leakage occurred in only 2% of vertebral bodies. Fractures of adjacent vertebral bodies were found in 11%. Good preinterventional diagnostics and intraoperative imaging are necessary to make the balloon kyphoplasty a successful application. (orig.) [de

  18. An Efficient Method of Vibration Diagnostics For Rotating Machinery Using a Decision Tree

    Directory of Open Access Journals (Sweden)

    Bo Suk Yang

    2000-01-01

    Full Text Available This paper describes an efficient method to automatize vibration diagnosis for rotating machinery using a decision tree, which is applicable to vibration diagnosis expert system. Decision tree is a widely known formalism for expressing classification knowledge and has been used successfully in many diverse areas such as character recognition, medical diagnosis, and expert systems, etc. In order to build a decision tree for vibration diagnosis, we have to define classes and attributes. A set of cases based on past experiences is also needed. This training set is inducted using a result-cause matrix newly developed in the present work instead of using a conventionally implemented cause-result matrix. This method was applied to diagnostics for various cases taken from published work. It is found that the present method predicts causes of the abnormal vibration for test cases with high reliability.

  19. Detecting microcalcifications in mammograms by using SVM method for the diagnostics of breast cancer

    Science.gov (United States)

    Wan, Baikun; Wang, Ruiping; Qi, Hongzhi; Cao, Xuchen

    2005-01-01

    Support vector machine (SVM) is a new statistical learning method. Compared with the classical machine learning methods, SVM learning discipline is to minimize the structural risk instead of the empirical risk of the classical methods, and it gives better generative performance. Because SVM algorithm is a convex quadratic optimization problem, the local optimal solution is certainly the global optimal one. In this paper a SVM algorithm is applied to detect the micro-calcifications (MCCs) in mammograms for the diagnostics of breast cancer that has not been reported yet. It had been tested with 10 mammograms and the results show that the algorithm can achieve a higher true positive in comparison with artificial neural network (ANN) based on the empirical risk minimization, and is valuable for further study and application in the clinical engineering.

  20. Safety and reliability of pressure components with special emphasis on advanced methods of NDT. Vol. 1

    International Nuclear Information System (INIS)

    1986-01-01

    24 papers discuss various methods for nondestructive testing of materials, e.g. eddy current measurement, EMAG analyser, tomography, ultrasound, holographic interferometry, and optical sound field camera. Special consideration is given to mathematical programmes and tests allowing to determine fracture-mechanical parameters and to assess cracks in various components, system parts and individual specimens both in pressurized systems and NPP systems. Studies focus on weld seams and adjacent areas. (DG) [de

  1. [Diagnostic agreement between two glycosylated a1b hemoglobin methods in Primary Care].

    Science.gov (United States)

    Villar-del-Campo, M C; Rodríguez-Caravaca, G; Gil-Yonte, P; Cidoncha-Calderón, E; García-Cruces Méndez, J; Donnay-Pérez, S

    2014-01-01

    Several methods are available for measuring glycosylated A1c hemoglobin (HbA1c), all rapid methods for point of care use in a clinical or laboratory setting. This study attempts to compare the diagnostic agreement between two methods for detection of HbA1c. A descriptive cross-sectional study of diagnostic agreement was carried out in the Los Carmenes Health Centre. Two groups of patients -with and without type 2 diabetes- were consecutively included. A method for point-of-care use in a Primary Care Clinic setting (DCA(TM) Systems Siemens(®)) was compared with a laboratory test (chromatographic analysis). An analysis was made of the mean concentration of HbA1c, the agreement between methods, using the intra-class correlation coefficient (CCLA1) and the Bland-Altman method. A total of 102 patients were included, 62 diabetic (60.8%) and 40 non-diabetic (39.2%). The overall mean HbA1c was 6.46% (SD=0.88) in the analysis using capillary blood in the clinic with the DCA™ system, and 6.44% (SD=0.86) using the laboratory test (P>.05). The degree of agreement between the two tests was 0.975 (95% CI: 0.963-0.983). The mean of the differences between the results of the two assessed tests was 0.024 (SD=0.27). The percentage of points outside the limits of optimal agreement, as defined in the Bland-Altman graph, was 2.5%. Diagnostic agreement between a method for point-of-care use in a Primary Health Care Clinic and a laboratory test was very high. Detection at the point-of-care allows a quick and simple assessment of HbA1c. Copyright © 2013 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  2. Chosen interval methods for solving linear interval systems with special type of matrix

    Science.gov (United States)

    Szyszka, Barbara

    2013-10-01

    The paper is devoted to chosen direct interval methods for solving linear interval systems with special type of matrix. This kind of matrix: band matrix with a parameter, from finite difference problem is obtained. Such linear systems occur while solving one dimensional wave equation (Partial Differential Equations of hyperbolic type) by using the central difference interval method of the second order. Interval methods are constructed so as the errors of method are enclosed in obtained results, therefore presented linear interval systems contain elements that determining the errors of difference method. The chosen direct algorithms have been applied for solving linear systems because they have no errors of method. All calculations were performed in floating-point interval arithmetic.

  3. Integrated method development of general and special students stamina involved in the fight

    Directory of Open Access Journals (Sweden)

    N.A. Alekseev

    2014-06-01

    Full Text Available Purpose : testing the effectiveness of methods of development of general and special endurance cadets wrestlers. Material : the experiment was attended by 20 students aged 18-20 years (10-12 years experience of employment, qualifications - candidates for the master of sports and master of sports. Classes are held 10 times a week, lasting for 120 minutes. Results : the developed methodology based on the application of a special set of exercises. Technique promotes rapid increase endurance level students. The directions of increasing endurance and performance of students. As an exercise for the development of general endurance recommended: motocross race, gymnastics, sports (rugby, soccer. As an exercise for the development of special endurance recommended: Attempted partner with high intensity (8-9 shots in 10 seconds Perform five series, consisting of 5 spurts (the maximum number of shots in 10 seconds And run shots at a moderate pace (4 -5 throws for 10 seconds ; training and educational training bout, fight quadruples (fight lasts until the transition to the fight lying down or throw up. Conclusions : the increase in special endurance cadets should be in parallel with the improvement of overall fitness.

  4. Diagnostic validity of methods for assessment of swallowing sounds: a systematic review.

    Science.gov (United States)

    Taveira, Karinna Veríssimo Meira; Santos, Rosane Sampaio; Leão, Bianca Lopes Cavalcante de; Neto, José Stechman; Pernambuco, Leandro; Silva, Letícia Korb da; De Luca Canto, Graziela; Porporatti, André Luís

    2018-02-03

    Oropharyngeal dysphagia is a highly prevalent comorbidity in neurological patients and presents a serious health threat, which may lead to outcomes of aspiration pneumonia, ranging from hospitalization to death. This assessment proposes a non-invasive, acoustic-based method to differentiate between individuals with and without signals of penetration and aspiration. This systematic review evaluated the diagnostic validity of different methods for assessment of swallowing sounds, when compared to Videofluroscopic of Swallowing Study (VFSS) to detect oropharyngeal dysphagia. Articles in which the primary objective was to evaluate the accuracy of swallowing sounds were searched in five electronic databases with no language or time limitations. Accuracy measurements described in the studies were transformed to construct receiver operating characteristic curves and forest plots with the aid of Review Manager v. 5.2 (The Nordic Cochrane Centre, Copenhagen, Denmark). The methodology of the selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. The final electronic search revealed 554 records, however only 3 studies met the inclusion criteria. The accuracy values (area under the curve) were 0.94 for microphone, 0.80 for Doppler, and 0.60 for stethoscope. Based on limited evidence and low methodological quality because few studies were included, with a small sample size, from all index testes found for this systematic review, Doppler showed excellent diagnostic accuracy for the discrimination of swallowing sounds, whereas microphone-reported good accuracy discrimination of swallowing sounds of dysphagic patients and stethoscope showed best screening test. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  5. Qualitative and mixed methods research in dissemination and implementation science: introduction to the special issue.

    Science.gov (United States)

    Southam-Gerow, Michael A; Dorsey, Shannon

    2014-01-01

    This special issue provides examples of how qualitative and mixed methods research approaches can be used in dissemination and implementation science. In this introductory article, we provide a brief rationale for why and how qualitative and mixed methods approaches can be useful in moving the field forward. Specifically, we provide a brief primer on common qualitative methods, including a review of guidelines provided by the National Institutes of Health. Next, we introduce the six articles in the issue. The first of the articles by Palinkas represents a more thorough and authoritative discussion related to qualitative methods, using the other five articles in the issue (and other published works) as examples. The remaining five articles are empirical and/or descriptive articles of recently completed or ongoing qualitative or mixed methods studies related to dissemination and implementation of evidence-based practices for children and adolescents.

  6. Schlieren method diagnostics of plasma compression in front of coaxial gun

    International Nuclear Information System (INIS)

    Kravarik, J.; Kubes, P.; Hruska, J.; Bacilek, J.

    1983-01-01

    The schlieren method employing a movable knife edge placed in the focal plane of a laser beam was used for the diagnostics of plasma produced by a coaxial plasma gun. When compared with the interferometric method reported earlier, spatial resolution was improved by more than one order of magnitude. In the determination of electron density near the gun orifice, spherical symmetry of the current sheath inhomogeneities and cylindrical symmetry of the compression maximum were assumed. Radial variation of electron density could be reconstructed from the photometric measurements of the transversal variation of schlieren light intensity. Due to small plasma dimensions, electron density was determined directly from the knife edge shift necessary for shadowing the corresponding part of the picture. (J.U.)

  7. Handbook of Coherent-Domain Optical Methods Biomedical Diagnostics, Environmental Monitoring, and Materials Science

    CERN Document Server

    2013-01-01

    This Handbook provides comprehensive coverage of laser and coherent-domain methods as applied to biomedicine, environmental monitoring, and materials science. Worldwide leaders in these fields describe the fundamentals of light interaction with random media and present an overview of basic research. The latest results on coherent and polarization properties of light scattered by random media, including tissues and blood, speckles formation in multiple scattering media, and other non-destructive interactions of coherent light with rough surfaces and tissues, allow the reader to understand the principles and applications of coherent diagnostic techniques. The expanded second edition has been thoroughly updated with particular emphasis on novel coherent-domain techniques and their applications in medicine and environmental science. Volume 1 describes state-of-the-art methods of coherent and polarization optical imaging, tomography and spectroscopy; diffusion wave spectroscopy; elastic, quasi-elastic and inelasti...

  8. Study on diagnostic plant analyzer method for support of emergency operation

    International Nuclear Information System (INIS)

    Yoshikawa, H.; Gofuku, A.; Itoh, K.; Wakabayashi, J.

    1986-01-01

    Methods of time-critical diagnostic plant analyzer are investigated which would serve as support to emergency operation of nuclear power plant. A faster-than-real-time simulator code TOKRAC is developed for analyzing PWR primary loop thermo-hydraulics of small-break LOCA and it is applied for a numerical experiment of initial phase of TMI-2 accident. TOKRAC resulted in a good agreement with a RELAP4/MOD6 calculation and the plant record with as fast as can one-tenth of real time. A real-time estimator of SG heat transfer rate based on Kalman filter is proposed and its applicability is verified using LOFT ATWS experimental data. With regards to how to integrate those methods into the software system in operation support center, a new concept of module-based simulation system is proposed which aims at offering a flexible and human-cognitive oriented environment for various analytical tool development

  9. Receiver operating characteristic (ROC) curves: review of methods with applications in diagnostic medicine

    Science.gov (United States)

    Obuchowski, Nancy A.; Bullen, Jennifer A.

    2018-04-01

    Receiver operating characteristic (ROC) analysis is a tool used to describe the discrimination accuracy of a diagnostic test or prediction model. While sensitivity and specificity are the basic metrics of accuracy, they have many limitations when characterizing test accuracy, particularly when comparing the accuracies of competing tests. In this article we review the basic study design features of ROC studies, illustrate sample size calculations, present statistical methods for measuring and comparing accuracy, and highlight commonly used ROC software. We include descriptions of multi-reader ROC study design and analysis, address frequently seen problems of verification and location bias, discuss clustered data, and provide strategies for testing endpoints in ROC studies. The methods are illustrated with a study of transmission ultrasound for diagnosing breast lesions.

  10. Method for Evaluating Information to Solve Problems of Control, Monitoring and Diagnostics

    Science.gov (United States)

    Vasil'ev, V. A.; Dobrynina, N. V.

    2017-06-01

    The article describes a method for evaluating information to solve problems of control, monitoring and diagnostics. It is necessary for reducing the dimensionality of informational indicators of situations, bringing them to relative units, for calculating generalized information indicators on their basis, ranking them by characteristic levels, for calculating the efficiency criterion of a system functioning in real time. The design of information evaluation system has been developed on its basis that allows analyzing, processing and assessing information about the object. Such object can be a complex technical, economic and social system. The method and the based system thereof can find a wide application in the field of analysis, processing and evaluation of information on the functioning of the systems, regardless of their purpose, goals, tasks and complexity. For example, they can be used to assess the innovation capacities of industrial enterprises and management decisions.

  11. A Self-diagnostic Method for the Electrode Adhesion of an Electromagnetic Flow-meter

    Directory of Open Access Journals (Sweden)

    Wen-Hua Cui

    2014-07-01

    Full Text Available Electrodes of electromagnetic flow-meter are subject to contamination in sewage measurement. In this paper, the relationship between the internal resistance of the flow-induced voltage and the electrode contamination is analyzed on the basis of numerical analysis. A new self- diagnostic method for electrode adhesion with additional excitation based on photovoltaic cell is proposed, in which magnetic excitation for flow-rate measurement and electric excitation for electrode self-diagnosis is divided in both time domain and frequency domain. A dual-excited electromagnetic flow-meter with electrode self-diagnosis was designed and validated. Simulation experiments based on the change of the internal resistance of the flow-induced voltage were carried out. And the experimental results fully show that this new method is feasible and promising.

  12. Reliability studies of diagnostic methods in Indian traditional Ayurveda medicine: An overview

    Science.gov (United States)

    Kurande, Vrinda Hitendra; Waagepetersen, Rasmus; Toft, Egon; Prasad, Ramjee

    2013-01-01

    Recently, a need to develop supportive new scientific evidence for contemporary Ayurveda has emerged. One of the research objectives is an assessment of the reliability of diagnoses and treatment. Reliability is a quantitative measure of consistency. It is a crucial issue in classification (such as prakriti classification), method development (pulse diagnosis), quality assurance for diagnosis and treatment and in the conduct of clinical studies. Several reliability studies are conducted in western medicine. The investigation of the reliability of traditional Chinese, Japanese and Sasang medicine diagnoses is in the formative stage. However, reliability studies in Ayurveda are in the preliminary stage. In this paper, examples are provided to illustrate relevant concepts of reliability studies of diagnostic methods and their implication in practice, education, and training. An introduction to reliability estimates and different study designs and statistical analysis is given for future studies in Ayurveda. PMID:23930037

  13. Some methods of analysis and diagnostics of corroded components from nuclear power plant

    International Nuclear Information System (INIS)

    Mogosan, S.; Radulescu, M.; Fulger, M.; Stefanescu, D.

    2010-01-01

    In Nuclear Power Plants (NPP) it is necessary to ensure a longer and safe operation as difficult and expensive it is the maintenance of these very complex installations and equipment. In this regard, The Analysis and Diagnostic Laboratory Corroded Metal Components in Nuclear Facilities-LADICON; was authorized RENAR and CNCAN (National Commission for Nuclear Activities Control) notified as a testing laboratory for nuclear-grade materials. As part of the investigation and evaluation of corrosion behavior for these materials two types of test methods are used i.e. longer corrosion tests such as: autoclaving at high temperature and pressure in different chemical media-specific patterns in NPP and accelerated methods like: electrochemical techniques, accelerated chemical tests, etc. This paper presents some methods of analysis for materials corrosion; methods of assessment of corrosion of structural materials exposed to specific operating conditions and environment in NPPs. The electrochemical measurements show the following advantages: a) Allowing a direct method to accelerate the corrosion processes without altering the environment, b) It can be used as an nondestructive tool for assessing the rate of corrosion and c) Offers the possibility of conducting such investigations in - situ and ex- situ. Corroborating the environmental chemistry that was born on samples movies investigation results obtained by the methods above, it is possible to identify the types of corrosion of the materials and sometimes even those processes and mechanisms of corrosion. (authors)

  14. A file study of refugee children referred to specialized mental health care: from an individual diagnostic to an ecological perspective.

    Science.gov (United States)

    Villanueva O'Driscoll, Julia; Serneels, Geertrui; Imeraj, Lindita

    2017-11-01

    The past years have been characterized by a large refugee crisis across the globe. The exposure to preflight, flight, and resettlement stressors puts refugee children and their families at risk of developing emotional and behavioral disorders. A unique Western-based approach of mental health problems seems to be insufficient to address the complexity of interactions between individual vulnerabilities and more ecological surrounding systems. We looked into (1) the reasons for referral; and (2) the process diagnostic outcomes after ethnopsychiatric and psychological assessment. We conducted a thematic content analysis on 93 files of refugee children. The findings suggest that mental health care professionals need to hold into account the multiplicity and intertwining of ongoing challenges to the well-being of refugee children. The integration of a Western-based psychiatric assessment with a more ecologically based view can lead to a more culturally sensitive approach in refugee children and their families. This way, both under- and overdiagnosis of psychiatric disorders could be avoided to further optimalise mental health care in this population.

  15. Special physical examination tests for superior labrum anterior posterior shoulder tears are clinically limited and invalid: a diagnostic systematic review.

    Science.gov (United States)

    Calvert, Eric; Chambers, Gordon Keith; Regan, William; Hawkins, Robert H; Leith, Jordan M

    2009-05-01

    The diagnosis of a superior labrum anterior posterior (SLAP) lesion through physical examination has been widely reported in the literature. Most of these studies report high sensitivities and specificities, and claim to be accurate, valid, and reliable. The purpose of this study was to critically evaluate these studies to determine if there was sufficient evidence to support the use of the SLAP physical examination tests as valid and reliable diagnostic test procedures. Strict epidemiologic methodology was used to obtain and collate all relevant articles. Sackett's guidelines were applied to all articles. Confidence intervals and likelihood ratios were determined. Fifteen of 29 relevant studies met the criteria for inclusion. Only one article met all of Sackett's critical appraisal criteria. Confidence intervals for both the positive and negative likelihood ratios contained the value 1. The current literature being used as a resource for teaching in medical schools and continuing education lacks the validity necessary to be useful. There are no good physical examination tests that exist for effectively diagnosing a SLAP lesion.

  16. Diagnostic value of the digital subtraction angiography of brain tumors. With special reference to the significance of tumor stains

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Yoshifumi; Matsukado, Yasuhiko; Takahashi, Mutsumasa

    1986-10-01

    Digital subtraction angiography (DSA) in 110 cases of brain tumors were studied in comparison with conventional angiography (CA). The dural sinuses and tumor stains of meningiomas, particularly tuberculum sellae meningioma, were better shown by intravenous DSA (IV-DSA) than by CA. IV-DSA clearly demonstrated bilateral carotid arteries and was able to rule out the coexistence of the intracranial aneurysm in 88 % of 32 cases with pituitary adenomas. Combination of IV-DSA and high resolution computed tomography has replaced CA to determine surgical indication of patients with pituitary adenomas. Intra-arterial DSA (IA-DSA) was diagnostic and well comparable to CA in identifying main cerebral vasculature over 1 mm in diameter. As to the small arteries under 1 mm and fine tumor vessels, IA-DSA provided less information or none at all. However, IA-DSA was superior to CA for visualization of tumor stains. Not only in most of meningiomas and hemangioblastomas, but in some astrocytomas and oligodendrogliomas, marked tumor stains were well demonstrated on DSA, and DSA provided surgical anatomy for neurosurgeons because of high contrast resolutions. Careful attention should be paid because tumor stains may overestimate tumor vascularity.

  17. Interobserver Reliability of Four Diagnostic Methods Using Traditional Korean Medicine for Stroke Patients

    Directory of Open Access Journals (Sweden)

    Ju Ah Lee

    2014-01-01

    Full Text Available Objective. The aim of this study is to evaluate the consistency of pattern identification (PI, a set of diagnostic indicators used by traditional Korean medicine (TKM clinicians. Methods. A total of 168 stroke patients who were admitted into oriental medical university hospitals from June 2012 through January 2013 were included in the study. Using the PI indicators, each patient was independently diagnosed by two experts from the same department. Interobserver consistency was assessed by simple percentage agreement as well as by kappa and AC1 statistics. Results. Interobserver agreement on the PI indicators (for all patients was generally high: pulse diagnosis signs (AC1=0.66–0.89; inspection signs (AC1=0.66–0.95; listening/smelling signs (AC1=0.67–0.88; and inquiry signs (AC1=0.62–0.94. Conclusion. In four examinations, there was moderate agreement between the clinicians on the PI indicators. To improve clinician consistency (e.g., in the diagnostic criteria used, it is necessary to analyze the reasons for inconsistency and to improve clinician training.

  18. The Value of Naproxen Test as a Diagnostic Method to Differentiate Cause of Fever

    Directory of Open Access Journals (Sweden)

    Omer Coskun

    2012-12-01

    Full Text Available Objective: Fever of whatever etiology still remains a perplexing problem to both clinicians and investigators. Increasingly, its role in connective tissue diseases, malignancies and other inflammatory disorders is slowly supplanting the exclusivity of the symptom to just infectious conditions. This study aims to determine the sensitivity of the naproxen test and the diagnostic value in patients with a prolonged febrile illness. Methods: We evaluated twenty patients had been administered the naproxen test. Fever lysis after or within the time frame of drug administration was interpreted as a infectious or an infectious condition. Results: Infectious diseases etiology was detected at 15 patients. 12 and 3 of them responded to naproxen test at the first and second days respectively. Two of non-infectious etiology patients remained unanswered. Conclusion: This study clearly showed that the naproxen test cannot be relied upon to guide diagnostic decision making in patients with fever unknown origin. [TAF Prev Med Bull 2012; 11(6.000: 779-782

  19. A comparison between workshop and DVD methods of training for physiotherapists in diagnostic ultrasound

    International Nuclear Information System (INIS)

    McKiernan, Sharmaine; Chiarelli, Pauline; Warren-Forward, Helen

    2012-01-01

    Diagnostic ultrasound has expanded into physiotherapy though training in the modality appears to be and is reported by physiotherapists as limited. To address this, a training package was specifically developed for physiotherapists within Australia. The aim of this study was to evaluate the training package for improved educational outcome and to ascertain if there was a difference in outcome between two forms of delivery. The training package was delivered either during a workshop, where the training package was delivered face to face, or via a self paced DVD, which was mailed to participants. Both participant groups completed a web based assessment prior to and at the completion of the training. The assessment assessed their knowledge in ultrasound physics, scanning technique and anatomy. Pre and post training assessment scores were available for 84 participants who attended a workshop and 96 participants who received the DVD. Important and statistically significant (p < 0.05) increases in assessment scores from the beginning to the end of the training program were seen in both groups. On average, workshop participant scores improved by 37% and DVD participant scores improved by 27%. No statistical difference in the post assessment scores of the workshop trained or DVD trained participants was evident. On comparison, no statistically significant difference between the two methods of training; workshop and DVD, was found so both can be seen to be beneficial to the professional development of the physiotherapist in the use of diagnostic ultrasound within their profession.

  20. Comprehensive and Methodical: Diagnostic and Management Approaches to Rapidly Progressive Dementia.

    Science.gov (United States)

    Mahajan, Supriya; Appleby, Brian S

    2017-09-30

    Purpose of review The sudden emergence of a change in cognitive abilities or behavior is an important symptom that warrants medical evaluation and may represent the early stages of a rapidly progressive dementia (RPD). To correctly ascertain the cause of RPD in a given patient, the clinician must be methodical and knowledgeable about the range of potential causes and must move forward with supportive treatment, and in some cases empiric treatment, based on clinical features alone. Recent findings Significant advances in prion disease biomarkers, the molecular features of rapidly progressive Alzheimer's disease, and new detection of autoimmune limbic encephalitis disease entities have caused a shift in the diagnostic and treatment framework of RPD. Additionally, in the past decade, emerging retrospective data have led to suggested treatments in autoimmune encephalitis that, if instituted early, can protect patients against residual deficits and disease relapse. Summary Here, we provide an integrative clinical and diagnostic treatment approach that is applicable to the various forms of RPD. We have highlighted the clinical features of selected types of RPD that have experienced advances in the last 10-15 years.

  1. Regular pipeline maintenance of gas pipeline using technical operational diagnostics methods

    Energy Technology Data Exchange (ETDEWEB)

    Volentic, J [Gas Transportation Department, Slovensky plynarensky priemysel, Slovak Gas Industry, Bratislava (Slovakia)

    1998-12-31

    Slovensky plynarensky priemysel (SPP) has operated 17 487 km of gas pipelines in 1995. The length of the long-line pipelines reached 5 191 km, distribution network was 12 296 km. The international transit system of long-line gas pipelines ranged 1 939 km of pipelines of various dimensions. The described scale of transport and distribution system represents a multibillion investments stored in the ground, which are exposed to the environmental influences and to pipeline operational stresses. In spite of all technical and maintenance arrangements, which have to be performed upon operating gas pipelines, the gradual ageing takes place anyway, expressed in degradation process both in steel tube, as well as in the anti-corrosion coating. Within a certain time horizon, a consistent and regular application of methods and means of in-service technical diagnostics and rehabilitation of existing pipeline systems make it possible to save substantial investment funds, postponing the need in funds for a complex or partial reconstruction or a new construction of a specific gas section. The purpose of this presentation is to report on the implementation of the programme of in-service technical diagnostics of gas pipelines within the framework of regular maintenance of SPP s.p. Bratislava high pressure gas pipelines. (orig.) 6 refs.

  2. Assessment of diagnostic methods for determining degradation of motor-operated valves

    International Nuclear Information System (INIS)

    Haynes, H.D.; Farmer, W.S.

    1992-01-01

    The Oak Ridge National Laboratory (ORNL) has carried out a comprehensive aging assessment of motor-operated valves (MOVs) in support of the Nuclear Plant Aging Research (NPAR) program. This paper provides a summary of the ORNL MOV aging assessment with emphasis on the identification, evaluation, and application of MOV monitoring methods and techniques. The diagnostic information available from any MOV measurable parameters was evaluated by ORNL using MOVs that were mounted on test stands. Those tests led to the conclusion that the single most informative MOV measurable parameter was also the one which was most easily acquired, namely the motor current. Motor current signature analysis (MCSA) was found to provide detailed information related to the condition of the motor, motor operator, and valve across a wide range of levels. As part of the MOV aging assessment, several tests were carried out by ORNL on MOVs having implanted defects and degradations. Tests were also performed on many MOVs located within a nuclear power plant. In addition, ORNL participated in the Gate Valve Flow Interruption Blowdown Test program carried out at Wyle Laboratories in Huntsville, Alabama. Results from all of these tests are summarized in this paper and several selected examples are given. Other areas covered in this paper include descriptions of relevant regulatory issues and activities, other related diagnostics research at ORNL, and interactions ORNL has had with outside organizations for the purpose of disseminating research results

  3. Regular pipeline maintenance of gas pipeline using technical operational diagnostics methods

    Energy Technology Data Exchange (ETDEWEB)

    Volentic, J. [Gas Transportation Department, Slovensky plynarensky priemysel, Slovak Gas Industry, Bratislava (Slovakia)

    1997-12-31

    Slovensky plynarensky priemysel (SPP) has operated 17 487 km of gas pipelines in 1995. The length of the long-line pipelines reached 5 191 km, distribution network was 12 296 km. The international transit system of long-line gas pipelines ranged 1 939 km of pipelines of various dimensions. The described scale of transport and distribution system represents a multibillion investments stored in the ground, which are exposed to the environmental influences and to pipeline operational stresses. In spite of all technical and maintenance arrangements, which have to be performed upon operating gas pipelines, the gradual ageing takes place anyway, expressed in degradation process both in steel tube, as well as in the anti-corrosion coating. Within a certain time horizon, a consistent and regular application of methods and means of in-service technical diagnostics and rehabilitation of existing pipeline systems make it possible to save substantial investment funds, postponing the need in funds for a complex or partial reconstruction or a new construction of a specific gas section. The purpose of this presentation is to report on the implementation of the programme of in-service technical diagnostics of gas pipelines within the framework of regular maintenance of SPP s.p. Bratislava high pressure gas pipelines. (orig.) 6 refs.

  4. The Brief Introduction of Different Laser Diagnostics Methods Used in Aeroengine Combustion Research

    Directory of Open Access Journals (Sweden)

    Fei Xing

    2016-01-01

    Full Text Available Combustion test diagnosis has always been one of the most important technologies for the development of aerospace engineering. The traditional methods of measurement have been unable to meet the requirements of accurate capture of the flow field in the development process of the aeroengine combustor. Therefore, the development of high-precision measurement and diagnostic techniques to meet the needs of the aeroengine combustor design is imperative. Laser diagnostics techniques developed quickly in the past several years. They are used to measure the parameters of the combustion flow field such as velocity, temperature, and components concentration with high space and time resolution and brought no disturbance. Planar laser-induced fluorescence, coherent anti-Stokes Raman scattering, tunable diode laser absorption spectroscopy, and Raman scattering were introduced systemically in this paper. After analysis of their own advantages and disadvantages, the authors considered validated Raman scattering system and Tunable Diode Laser Absorption Tomography are more suitable for research activities on aeroengine combustion systems.

  5. Technical Note: Method to correlate whole-specimen histopathology of radical prostatectomy with diagnostic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    McGrath, Deirdre M., E-mail: d.mcgrath@sheffield.ac.uk; Lee, Jenny; Foltz, Warren D. [Radiation Medicine Program, Princess Margaret Hospital, University Health Network, Toronto, Ontario M5G 2M9 (Canada); Samavati, Navid [Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M5S 3G9 (Canada); Jewett, Michael A. S. [Departments of Surgery (Urology) and Surgical Oncology, Princess Margaret Cancer Centre, University Health Network and University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Kwast, Theo van der [Pathology Department, University Health Network, Toronto, Ontario M5G 2C4 (Canada); Chung, Peter [Radiation Medicine Program, Princess Margaret Hospital, University Health Network and the University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Ménard, Cynthia [Radiation Medicine Program, Princess Margaret Hospital, University Health Network and the University of Toronto, Toronto, Ontario M5G 2M9, Canada and Centre Hospitalier de l’Université de Montréal, 1058 Rue Saint-Denis, Montréal, Québec H2X 3J4 (Canada); Brock, Kristy K. [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48108 (United States)

    2016-03-15

    Purpose: Validation of MRI-guided tumor boundary delineation for targeted prostate cancer therapy is achieved via correlation with gold-standard histopathology of radical prostatectomy specimens. Challenges to accurate correlation include matching the pathology sectioning plane with the in vivo imaging slice plane and correction for the deformation that occurs between in vivo imaging and histology. A methodology is presented for matching of the histological sectioning angle and position to the in vivo imaging slices. Methods: Patients (n = 4) with biochemical failure following external beam radiotherapy underwent diagnostic MRI to confirm localized recurrence of prostate cancer, followed by salvage radical prostatectomy. High-resolution 3-D MRI of the ex vivo specimens was acquired to determine the pathology sectioning angle that best matched the in vivo imaging slice plane, using matching anatomical features and implanted fiducials. A novel sectioning device was developed to guide sectioning at the correct angle, and to assist the insertion of reference dye marks to aid in histopathology reconstruction. Results: The percentage difference in the positioning of the urethra in the ex vivo pathology sections compared to the positioning in in vivo images was reduced from 34% to 7% through slicing at the best match angle. Reference dye marks were generated, which were visible in ex vivo imaging, in the tissue sections before and after processing, and in histology sections. Conclusions: The method achieved an almost fivefold reduction in the slice-matching error and is readily implementable in combination with standard MRI technology. The technique will be employed to generate datasets for correlation of whole-specimen prostate histopathology with in vivo diagnostic MRI using 3-D deformable registration, allowing assessment of the sensitivity and specificity of MRI parameters for prostate cancer. Although developed specifically for prostate, the method is readily

  6. Technical Note: Method to correlate whole-specimen histopathology of radical prostatectomy with diagnostic MR imaging

    International Nuclear Information System (INIS)

    McGrath, Deirdre M.; Lee, Jenny; Foltz, Warren D.; Samavati, Navid; Jewett, Michael A. S.; Kwast, Theo van der; Chung, Peter; Ménard, Cynthia; Brock, Kristy K.

    2016-01-01

    Purpose: Validation of MRI-guided tumor boundary delineation for targeted prostate cancer therapy is achieved via correlation with gold-standard histopathology of radical prostatectomy specimens. Challenges to accurate correlation include matching the pathology sectioning plane with the in vivo imaging slice plane and correction for the deformation that occurs between in vivo imaging and histology. A methodology is presented for matching of the histological sectioning angle and position to the in vivo imaging slices. Methods: Patients (n = 4) with biochemical failure following external beam radiotherapy underwent diagnostic MRI to confirm localized recurrence of prostate cancer, followed by salvage radical prostatectomy. High-resolution 3-D MRI of the ex vivo specimens was acquired to determine the pathology sectioning angle that best matched the in vivo imaging slice plane, using matching anatomical features and implanted fiducials. A novel sectioning device was developed to guide sectioning at the correct angle, and to assist the insertion of reference dye marks to aid in histopathology reconstruction. Results: The percentage difference in the positioning of the urethra in the ex vivo pathology sections compared to the positioning in in vivo images was reduced from 34% to 7% through slicing at the best match angle. Reference dye marks were generated, which were visible in ex vivo imaging, in the tissue sections before and after processing, and in histology sections. Conclusions: The method achieved an almost fivefold reduction in the slice-matching error and is readily implementable in combination with standard MRI technology. The technique will be employed to generate datasets for correlation of whole-specimen prostate histopathology with in vivo diagnostic MRI using 3-D deformable registration, allowing assessment of the sensitivity and specificity of MRI parameters for prostate cancer. Although developed specifically for prostate, the method is readily

  7. IR IMAGING AND VIBRATORY METHODS OF CONTROL AND DIAGNOSTICS OF THE EQUIPMENT AT OJSC «BSW – MANAGEMENT COMPANY OF HOLDING «BMC»

    Directory of Open Access Journals (Sweden)

    A. S. Shinkarev

    2017-01-01

    Full Text Available The article discusses the main methods of diagnostics of the equipment of OJSC «BSW – management company of holding «BMC». Presents results of diagnostics of various equipment with the description of the devices directly used for the diagnostic that can detect various defects of the equipment at the stage of their origination. Describes the advantages of these methods compared to other methods of control and diagnostics.

  8. Study of time-critical diagnostic method for emergency operation of nuclear power plant

    International Nuclear Information System (INIS)

    Gofuku, A.; Yoshikawa, H.; Itoh, K.; Wakabayashi, J.

    1986-01-01

    In order to support the emergency operation of nuclear power plant, the method of time-critical diagnostic plant analyzer has been investigated. The conception of the emergency operation support center is proposed and two types of plant analyzer may be installed in this center. One analyzer is a real-time tracking simulation code using the observed signals and another is a fast trend-prediction code. A real-time tracking code, TOKRAC, has been developed for analyzing the PWR primary loop thermo-hydraulics at SBLOCA, and the applicability of this code was examined by the numerical experiments for the initial phase transient of both TMI-2 accident and 6% coldleg SBLOCA of a Westinghouse-type PWR plant. The results showed that fairly good tracking was carried out by TOKRAC. The CPU time of TOKRAC was about 12-14 percent of real-time

  9. Handbook of coherent domain optical methods biomedical diagnostics, environmental and material science

    CERN Document Server

    2004-01-01

    For the first time in one set of books, coherent-domain optical methods are discussed in the framework of various applications, which are characterized by a strong light scattering. A few chapters describe basic research containing the updated results on coherent and polarized light non-destructive interactions with a scattering medium, in particular, diffraction, interference, and speckle formation at multiple scattering. These chapters allow for understanding coherent-domain diagnostic techniques presented in later chapters. A large portion of Volume I is dedicated to analysis of various aspects of optical coherence tomography (OCT) - a very new and growing field of coherent optics. Two chapters on laser scanning confocal microscopy give insight to recent extraordinary results on in vivo imaging and compare the possibilities and achievements of confocol, excitation multiphoton, and OCT microscopy. This two volume reference contains descriptions of holography, interferometry and optical heterodyning techniqu...

  10. Duplicated collecting system of a kidney complicated with hydronephrosis - diagnostic methods review: A case report

    International Nuclear Information System (INIS)

    Osmanski, P.; Plucinska, I.; Calka, K.; Kedzierski, B.; Jazwiec, P.

    2008-01-01

    Duplicated collecting system of a kidney occurs in 1.7-4.2% of the population. It is a complex, unilateral or bilateral, congenital abnormality of the pyelocalyceal system and the ureter. The 2 ureters fuse to form a single ureteral orifice or empty separately into the bladder (ureter duplex). Duplicated collecting systems with complete ureteric duplication may lead to developing vesicoureteral reflux, hydronephrosis, and urinary infection. This article presents a case of a 49-year-old woman with duplicated collecting system and hydronephrosis in the upper pole. The anomaly was diagnosed using urography, ultrasonography and computed tomography examination.The best method for diagnostics of the duplicated pyelocalyceal system complicated by hydronephrosis is computed tomography examination, especially multislice computed tomography. The authors present also the options for therapy (author)

  11. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  12. Embedded diagnostic, prognostic, and health management system and method for a humanoid robot

    Science.gov (United States)

    Barajas, Leandro G. (Inventor); Sanders, Adam M (Inventor); Reiland, Matthew J (Inventor); Strawser, Philip A (Inventor)

    2013-01-01

    A robotic system includes a humanoid robot with multiple compliant joints, each moveable using one or more of the actuators, and having sensors for measuring control and feedback data. A distributed controller controls the joints and other integrated system components over multiple high-speed communication networks. Diagnostic, prognostic, and health management (DPHM) modules are embedded within the robot at the various control levels. Each DPHM module measures, controls, and records DPHM data for the respective control level/connected device in a location that is accessible over the networks or via an external device. A method of controlling the robot includes embedding a plurality of the DPHM modules within multiple control levels of the distributed controller, using the DPHM modules to measure DPHM data within each of the control levels, and recording the DPHM data in a location that is accessible over at least one of the high-speed communication networks.

  13. Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods

    OpenAIRE

    Kênia de Fátima Carrijo; Elmiro Rosendo do Nascimento; Virginia Léo de Almeida Pereira; Nelson Morés; Catia Silene Klein; Leonardo Muliterno Domingues; Rogerio Tortelly

    2014-01-01

    ABSTRACT. Carrijo K.F., Nascimento E.R., Pereira V.L.A., Morés N., Klein, C.S., Domingues L.M. & Tortelly R. [Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods.] Diagnóstico da pneumonia enzoótica suína pela inspeção sanitária post mortem: comparação com outros métodos de diagnóstico. Revista Brasileira de Veterinária Brasileira 36(2):188-194, 2014. Faculdade de Medicina Veterinária, Universidade Federal de Uberlândia, Av. Par...

  14. Diagnostic Methods of Helicobacter pylori Infection for Epidemiological Studies: Critical Importance of Indirect Test Validation.

    Science.gov (United States)

    Miftahussurur, Muhammad; Yamaoka, Yoshio

    2016-01-01

    Among the methods developed to detect H. pylori infection, determining the gold standard remains debatable, especially for epidemiological studies. Due to the decreasing sensitivity of direct diagnostic tests (histopathology and/or immunohistochemistry [IHC], rapid urease test [RUT], and culture), several indirect tests, including antibody-based tests (serology and urine test), urea breath test (UBT), and stool antigen test (SAT) have been developed to diagnose H. pylori infection. Among the indirect tests, UBT and SAT became the best methods to determine active infection. While antibody-based tests, especially serology, are widely available and relatively sensitive, their specificity is low. Guidelines indicated that no single test can be considered as the gold standard for the diagnosis of H. pylori infection and that one should consider the method's advantages and disadvantages. Based on four epidemiological studies, culture and RUT present a sensitivity of 74.2-90.8% and 83.3-86.9% and a specificity of 97.7-98.8% and 95.1-97.2%, respectively, when using IHC as a gold standard. The sensitivity of serology is quite high, but that of the urine test was lower compared with that of the other methods. Thus, indirect test validation is important although some commercial kits propose universal cut-off values.

  15. Hybrid digital signal processing and neural networks for automated diagnostics using NDE methods

    International Nuclear Information System (INIS)

    Upadhyaya, B.R.; Yan, W.

    1993-11-01

    The primary purpose of the current research was to develop an integrated approach by combining information compression methods and artificial neural networks for the monitoring of plant components using nondestructive examination data. Specifically, data from eddy current inspection of heat exchanger tubing were utilized to evaluate this technology. The focus of the research was to develop and test various data compression methods (for eddy current data) and the performance of different neural network paradigms for defect classification and defect parameter estimation. Feedforward, fully-connected neural networks, that use the back-propagation algorithm for network training, were implemented for defect classification and defect parameter estimation using a modular network architecture. A large eddy current tube inspection database was acquired from the Metals and Ceramics Division of ORNL. These data were used to study the performance of artificial neural networks for defect type classification and for estimating defect parameters. A PC-based data preprocessing and display program was also developed as part of an expert system for data management and decision making. The results of the analysis showed that for effective (low-error) defect classification and estimation of parameters, it is necessary to identify proper feature vectors using different data representation methods. The integration of data compression and artificial neural networks for information processing was established as an effective technique for automation of diagnostics using nondestructive examination methods

  16. The Scientific Method, Diagnostic Bayes, and How to Detect Epistemic Errors

    Science.gov (United States)

    Vrugt, J. A.

    2015-12-01

    In the past decades, Bayesian methods have found widespread application and use in environmental systems modeling. Bayes theorem states that the posterior probability, P(H|D) of a hypothesis, H is proportional to the product of the prior probability, P(H) of this hypothesis and the likelihood, L(H|hat{D}) of the same hypothesis given the new/incoming observations, \\hat {D}. In science and engineering, H often constitutes some numerical simulation model, D = F(x,.) which summarizes using algebraic, empirical, and differential equations, state variables and fluxes, all our theoretical and/or practical knowledge of the system of interest, and x are the d unknown parameters which are subject to inference using some data, \\hat {D} of the observed system response. The Bayesian approach is intimately related to the scientific method and uses an iterative cycle of hypothesis formulation (model), experimentation and data collection, and theory/hypothesis refinement to elucidate the rules that govern the natural world. Unfortunately, model refinement has proven to be very difficult in large part because of the poor diagnostic power of residual based likelihood functions tep{gupta2008}. This has inspired te{vrugt2013} to advocate the use of 'likelihood-free' inference using approximate Bayesian computation (ABC). This approach uses one or more summary statistics, S(\\hat {D}) of the original data, \\hat {D} designed ideally to be sensitive only to one particular process in the model. Any mismatch between the observed and simulated summary metrics is then easily linked to a specific model component. A recurrent issue with the application of ABC is self-sufficiency of the summary statistics. In theory, S(.) should contain as much information as the original data itself, yet complex systems rarely admit sufficient statistics. In this article, we propose to combine the ideas of ABC and regular Bayesian inference to guarantee that no information is lost in diagnostic model

  17. Diagnostic Accuracy of Clinical Methods for Detection of Diabetic Sensory Neuropathy

    International Nuclear Information System (INIS)

    Arshad, A. R.; Alvi, K. Y.

    2016-01-01

    Objective: To determine the accuracy of clinical methods for detection of sensory neuropathy as compared to biothesiometry. Study Design: Cross-sectional analytical study. Place and Duration of Study: 1 Mountain Medical Battalion, Azad Kashmir, from October 2013 to September 2014. Methodology: Patients with type 2 diabetes were enrolled by convenience sampling. Exclusion criteria included other identifiable causes of neuropathy, extensive ulceration of feet, amputated feet, those on treatment for neuropathy and unwilling patients. Average of 3 vibration perception threshold values measured with a biothesiometer on distal hallux was calculated. Ten gm monofilament was used to examine touch sensation over dorsal surfaces of great toes. Vibration sensation was checked over the tips of great toes using 128Hz tuning fork. Ankle jerks were checked bilaterally. Result: Neuropathy (vibration perception threshold > 25 volts) was present in 34 (21.12 percentage) out of 161 patients and 93 (57.76 percentage) were symptomatic. Measures of diagnostic accuracy for monofilament, tuning fork and ankle jerks were: sensitivity 41.18 percentage, 55.88 percentage and 64.71 percentage; specificity 92.91 percentage, 93.70 percentage and 80.31 percentage; positive predictive value (PPV) 60.87 percentage, 70.37 percentage and 46.81 percentage; negative predictive value (NPV) 85.51 percentage, 88.81 percentage and 89.47 percentage; and, diagnostic accuracy 81.99 percentage, 85.71 percentage and 77.02 percentage, respectively. Values for any 1 positive sign, any 2 positive signs or all 3 positive signs were: sensitivity 35.29 percentage, 14.71 percentage and 32.35 percentage; specificity 81.89 percentage, 93.70 percentage and 99.21 percentage; PPV 34.29 percentage, 38.46 percentage and 91.67 percentage; NPV 82.54 percentage, 80.41 percentage and 84.56 percentage; and, diagnostic accuracy 72.05 percentage, 77.02 percentage and 85.09 percentage, respectively. Conclusion: Clinical methods are

  18. Methodology for the design of the method of siliceous sandstones operation using special software

    Directory of Open Access Journals (Sweden)

    Luis Ángel Lara-González

    2014-12-01

    Full Text Available The methodologies used for the design of the method of sandstones explotation by descending staggered banks using specialized software tools are reported. The data analyzed were collected in the field for the operating license 14816 in Melgar, Tolima. The characterization of the rock mass was held from physical and mechanical tests, performed on cylindrical test tubes in order to obtain the value of the maximum strenght and elastic modulus of the rock. The direction and dip of the sandstone package was rock. The direction and dip of the sandstone package was determined by using the stereographic projection whit DIPS®  software, and the safety factor of the slope was obtained with established banks whit SLIDE® . The slops are 8 meters high and 8 meters wide whit a tilt angle 60°, which generated a safety factor  of 2.1. The design  of the mining method was carried out with GEOVIA SURPAC® , at an early stage of development ascending to the level 11 of the exploitation, to then start mining in descending order to control the stabiLity of slopes. The results obtained allow a general methodology for the development of projects to optimize the process of evaluation and selection of mining method by using specialized design tools.

  19. Real time elastography - a non-invasive diagnostic method of small hepatocellular carcinoma in cirrhosis.

    Science.gov (United States)

    Gheorghe, Liana; Iacob, Speranta; Iacob, Razvan; Dumbrava, Mona; Becheanu, Gabriel; Herlea, Vlad; Gheorghe, Cristian; Lupescu, Ioana; Popescu, Irinel

    2009-12-01

    Small nodules (under 3 cm) detected on ultrasound (US) in cirrhotics represent the most challenging category for noninvasive diagnosis of hepatocellular carcinoma (HCC). To evaluate real-time sonoelastography as a noninvasive tool for the diagnosis of small HCC nodules in cirrhotic patients. 42 cirrhotic patients with 58 nodules (1-3 cm) were evaluated with real-time elastography (Hitachi EUB-6500); the mean intensity of colors red, blue, green were measured using a semi-quantitative method. Analysis of histograms for each color of the sonoelastography images was performed for quantifying the elasticity of nodule tissue in comparison with the cirrhotic liver tissue. AUROC curves were constructed to define the best cut-off points to distinguish malignant features of the nodules. Univariate and multivariate logistic regression analysis was performed. 595 sonoelastography images from 42 patients (25 men; 17 women) were analyzed. The mean age was 56.4 +/- 0.7 years and 69% patients were in Child-Pugh class A, 19% class B, 11% class C. For the mean intensity of green color AUROC=0.81, a cut-off value under 108.7 being diagnostic for HCC with a Sp=91.1%, Se=50%, PPV=92.1%, NPV=47.1%. Mean intensity of blue color proved to be an excellent diagnostic tool for HCC (AUROC=0.94); for a cut-off value greater than 128.9, Sp=92.2%, Se=78.9%, PPV=95.4%, NPV=68%. Independent predictive factors of HCC for a small nodule in cirrhotic patients were: blue color over 128.9 at sonoelastography and hypervascular appearance at Doppler US. US elastography is a promising method for the non-invasive diagnosis of early HCC. Blue color at elastography and hypervascular aspects are independent predictors of HCC.

  20. Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes

    Directory of Open Access Journals (Sweden)

    Beng Kwang Ng

    2013-01-01

    Full Text Available Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart. Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6% had ruptured membranes, while 24 patients (11.4% had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (179 of 179, and negative predictive value of 75.0% (24 of 32. By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (146 of 146, and negative predictive value of 36.9% (24 of 65 in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning, the nitrazine test alone or fern test alone.

  1. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: Recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L.; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J.; Haythornthwaite, Jennifer A.; Hollender, Lars; Jensen, Rigmor; John, Mike T.; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M.; Nixdorf, Donald R.; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M.; Zakrzewska, Joanna; Dworkin, Samuel F.

    2015-01-01

    Aims The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Methods Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project—the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. Results The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0

  2. PREFACE: Anti-counterfeit Image Analysis Methods (A Special Session of ICSXII)

    Science.gov (United States)

    Javidi, B.; Fournel, T.

    2007-06-01

    The International Congress for Stereology is dedicated to theoretical and applied aspects of stochastic tools, image analysis and mathematical morphology. A special emphasis on `anti-counterfeit image analysis methods' has been given this year for the XIIth edition (ICSXII). Facing the economic and social threat of counterfeiting, this devoted session presents recent advances and original solutions in the field. A first group of methods are related to marks located either on the product (physical marks) or on the data (hidden information) to be protected. These methods concern laser fs 3D encoding and source separation for machine-readable identification, moiré and `guilloche' engraving for visual verification and watermarking. Machine-readable travel documents are well-suited examples introducing the second group of methods which are related to cryptography. Used in passports for data authentication and identification (of people), cryptography provides some powerful tools. Opto-digital processing allows some efficient implementations described in the papers and promising applications. We would like to thank the reviewers who have contributed to a session of high quality, and the authors for their fine and hard work. We would like to address some special thanks to the invited lecturers, namely Professor Roger Hersch and Dr Isaac Amidror for their survey of moiré methods, Prof. Serge Vaudenay for his survey of existing protocols concerning machine-readable travel documents, and Dr Elisabet Pérez-Cabré for her presentation on optical encryption for multifactor authentication. We also thank Professor Dominique Jeulin, President of the International Society for Stereology, Professor Michel Jourlin, President of the organizing committee of ICSXII, for their help and advice, and Mr Graham Douglas, the Publisher of Journal of Physics: Conference Series at IOP Publishing, for his efficiency. We hope that this collection of papers will be useful as a tool to further

  3. Diagnostic Value of Manual and Computerized Methods of Dental Casts Analysis

    Directory of Open Access Journals (Sweden)

    H. Rahimi

    2009-06-01

    Full Text Available Objective: The aim of this study was to evaluate the validity of computerized and manual methods of dental cast analysis.Materials and Methods: Twenty set-ups of upper and lower casts using artificial teeth corresponding to various malocclusions were created for a diagnostic in vitro study. Values of tooth size were calculated from the isolated artificial teeth out of the set-ups, results were considered as a gold standard for the tooth size. Arch width was calculated from the existing set-ups on the dentins.Impressions were taken of the casts with alginate and duplicated with dental stone. Models were measured with digital caliper manually. Then images were taken from the occlusal views of the casts by a digital camera. Measurements were done on digital images with the AutoCAD software.The results of the computerized and manual methods were compared with the gold standard.Intra class correlation coefficient of reliability was used to measure the accuracy ofthe methods and the Friedman technique used to evaluate the significance of differences.Results: Results indicated that all measurements were highly correlated, e.g. gold standard and manual (0.9613-0.9991, gold standard and computerized (0.7118-0.9883, manual and computerized (0.6734-0.9914. Statistically significant differences were present between these methods (P<0.05, but they proved not to be clinically significant.Conclusion: Manual measurement is still the most accurate method when compared to the computerized measurements and the results of measurement by computer should be interpreted with caution.

  4. Reliability and limitation of various diagnostic methods including nuclear medicine in myocardial disease

    International Nuclear Information System (INIS)

    Tokuyasu, Yoshiki; Kusakabe, Kiyoko; Yamazaki, Toshio

    1981-01-01

    Electrocardiography (ECG), echocardiography, nuclear method, cardiac catheterization, left ventriculography and endomyocardial biopsy (biopsy) were performed in 40 cases of cardiomyopathy (CM), 9 of endocardial fibroelastosis and 19 of specific heart muscle disease, and the usefulness and limitation of each method was comparatively estimated. In CM, various methods including biopsy were performed. The 40 patients were classified into 3 groups, i.e., hypertrophic (17), dilated (20) and non-hypertrophic.non-dilated (3) on the basis of left ventricular ejection fraction and hypertrophy of the ventricular wall. The hypertrophic group was divided into 4 subgroups: 9 septal, 4 apical, 2 posterior and 2 anterior. The nuclear study is useful in assessing the site of the abnormal ventricular thickening, perfusion defect and ventricular function. Echocardiography is most useful in detecting asymmetric septal hypertrophy. The biopsy gives the sole diagnostic clue, especially in non-hypertrophic.non-dilated cardiomyopathy. ECG is useful in all cases but correlation with the site of disproportional hypertrophy was not obtained. (J.P.N.)

  5. Biochemical nature of familial amyloiditic polyneuropathy and a new diagnostic method by radioimmunoassay

    International Nuclear Information System (INIS)

    Nakazato, M.; Kanagawa, K.; Kurihara, T.

    1986-01-01

    Familial amyloidotic polyneuropathy (FAP) in Japan is clinically similar to that of Portugal. We have reported that amyloid fibril protein isolated from Japanese FAP cases is composed of a prealbumin variant in which a valine residue at position 30 is replaced by a methionine (Tawara et al., 1983). Furthermore, we have clarified that this prealbumin variant is present in the sera of Japanese FAP patients. There has been no definite method to detect this progressive illness before clinical manifestations appear. For the purpose of developing a new, noninvasive diagnostic method, we have established a radioimmunoassay (RIA) using a nonapeptide corresponding to the subsequence (22-30) of the prealbumin variant. The serum levels of the prealbumin variant in normal individuals, FAP patients, asymptomatic members of FAP families, primary and secondary amyloidosis cases are studied. The present RIA serves as a simple and definite method for an early detection of this disease and an appropriate genetic advice can be given to FAP patients and their families

  6. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network.

    Science.gov (United States)

    Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing

    2016-01-08

    A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method.

  7. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network

    Directory of Open Access Journals (Sweden)

    Ke Li

    2016-01-01

    Full Text Available A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF and Diagnostic Bayesian Network (DBN is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO. To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA is proposed to evaluate the sensitiveness of symptom parameters (SPs for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method.

  8. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network

    Science.gov (United States)

    Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing

    2016-01-01

    A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method. PMID:26761006

  9. Therapy evaluation and diagnostic accuracy in neuroendocrine tumours: assessment of radiological methods

    International Nuclear Information System (INIS)

    Elvin, A.

    1993-01-01

    The diagnostic accuracy of ultrasonically guided biopsy-gun biopsies was assessed in a group of 47 patients with suspected pancreatic carcinoma. A correct diagnosis was obtained in 44 of the 47 patients (94%). Biopsy-gun biopsy of the pancreas is considered a useful, reliable and non-traumatic method for the diagnosis of pancreatic malignancy. Twenty-five patients with known neuroendocrine tumour disease were biopsied with 1.2 mm and 0.9 mm biopsy-gun needles. The influence of treatment-related fibrosis was also evaluated. The overall diagnostic accuracy with the 0.9 mm needle was 69% as compared to 92% with the 1.2 mm needle. In order to assess the diagnostic accuracy rate for radiologists with different experience of biopsy procedures 175 cases of renal biopsy-gun biopsies were evaluated. No statistical significant difference was found between the different operators. The role of duplex Doppler ultrasound in monitoring interferon treatment-related changes in carcinoid metastases was evaluated. It present duplex Doppler ultrasound does not seem to play a role in the evaluation of tumour therapy in carcinoid patients. Therapy response evaluation was performed with MR imaging in a group of 17 patients with neuroendocrine liver metastases. A significant difference was found between patients responding to and patients with failure of treatment in terms of tumour T1, contrast enhancement and signal intensity ratio. This indicates that MR investigation may be used in therapy monitoring of patients with neuroendocrine metastases. The neuroendocrine-differentiated colonic carcinoma cell line (LCC-18) was transplanted to 29 mice to establish a tumour/animal model that would allow the monitoring of changes with MR imaging induced by interferon therapy and to evaluate whether the therapeutic response could be modulated by different interferon dosages. Interferon does not seem to have any prolonged anti-proliferative effect on the LCC-18 tumour cell line when transplanted to

  10. The Life Story Method in research about self-perception of people with special educational needs

    Directory of Open Access Journals (Sweden)

    Rosana Glat

    2009-09-01

    Full Text Available The present text discusses self-perception of people who are stigmatized due to intellectual (mental, sensorial and /or physical handicapped; global developmental disturbance or high abilities. For this aim, it analyses a group of researches (Master dissertations and PhD thesis in the field of Special Education in Graduate programs in Education and Psychology of Brazilian universities. All these studies had as theoretical-methodological reference the Life History Method, which utilizes as main data collection instrument the open interview, without a pre-determined guide. The data analyzed pointed out the validity of the Life History method for researches in Special Education and other areas of the so-called Applied Social and Human Sciences, since, among other aspects, it allows a descriptive-analytical global view of the situation or group under investigation. This methodology shows not only de needs and expectations of these groups of subjects, but, maybe even more important, the way in which the services and professionals that are in their disposition are being (or not effective. Life History research, therefore, besides the analysis of the daily experience, has, in itself, a propositional impact since the subject when narrating his life experiences, also reflects upon it, and points out his needs and strategies in order to adapt or overcome the restrictions imposed by his stigmatized condition.

  11. Comparative Study for the Accuracy of Helicobacter pylori Diagnostic Methods Associated with Some Inflammatory Factors

    Directory of Open Access Journals (Sweden)

    Eman N. Naji

    2018-04-01

    Full Text Available This Study was intended to diagnose H. pyiori the major causative pathogen in gastro duodenal irritation and ulceration. Differert techniques were used invasive tests (histopathological examina-tion, rapid urea CLO test and culture , while noninvasive tests includes (serological tests and stool antigen in addition to determination of some immune response factors (IgM , IgG , IgA as well as (IL – 8 and IFN – y in Ptients Sera. According to the results of invasive diagnostic method 30/113 (26.69% patients were considered to be infected and 83/113(73.31% patients were considered as noninfeted was contrasted with noninvasive diagnostic method 25/113 (22.14% patients were considered to be infected and 88/133(77.83% patients were considered as noninfeted. In order to get the overall percentage of the infected people included in this study, we merge the results of the two methods ,so we found out that the total infected patients with H. pylori diagnosed by invasive and noninvasive methods were 42 /113 (37.2% while the noninfected 71/113 (62.8 disseminated as 27/68(39.71% infect-ed male ,which was privileged than the infected female when it was 15/45(33.33%. The high prevalence of H. pylori infection in the age group ranging between (46-60 in male and female. Histology (invasive teq. and ECO rapid test (noninvasive teq. were considered as the ‘‘best techniques ’’ for H. pylori detection, in the outlook of its high specificity, sensitivity and because it detected the major number of H. pylori-positive patients along with the other techniques used in this work. The sensitivity, specificity, positive predictive values (PPV and negative predictive values (NPV for histology were 100,100,100 and 94.5% , respectively, while for the ECO rapid test they were 96, 93, 91.5, and 97.14%. Culture (invasive teq. and IgG anti H. pylori (noninvasive teq. coming secondly in the diagnosis of H. pylori infection because they detected a little fewer number of

  12. Diagnostic performance of a Lattice Boltzmann-based method for CT-based fractional flow reserve.

    Science.gov (United States)

    Giannopoulos, Andreas A; Tang, Anji; Ge, Yin; Cheezum, Michael K; Steigner, Michael L; Fujimoto, Shinichiro; Kumamaru, Kanako K; Chiappino, Dante; Della Latta, Daniele; Berti, Sergio; Chiappino, Sara; Rybicki, Frank J; Melchionna, Simone; Mitsouras, Dimitrios

    2018-02-20

    Fractional flow reserve (FFR) estimated from coronary computed tomography angiography (CT-FFR) offers non-invasive detection of lesion-specific ischaemia. We aimed to develop and validate a fast CT-FFR algorithm utilising the Lattice Boltzmann method for blood flow simulation (LBM CT-FFR). Sixty-four patients with clinically indicated CTA and invasive FFR measurement from three institutions were retrospectively analysed. CT-FFR was performed using an onsite tool interfacing with a commercial Lattice Boltzmann fluid dynamics cloud-based platform. Diagnostic accuracy of LBM CT-FFR ≤0.8 and percent diameter stenosis >50% by CTA to detect invasive FFR ≤0.8 were compared using area under the receiver operating characteristic curve (AUC). Sixty patients successfully underwent LBM CT-FFR analysis; 29 of 73 lesions in 69 vessels had invasive FFR ≤0.8. Total time to perform LBM CT-FFR was 40±10 min. Compared to invasive FFR, LBM CT-FFR had good correlation (r=0.64), small bias (0.009) and good limits of agreement (-0.223 to 0.206). The AUC of LBM CT-FFR (AUC=0.894, 95% confidence interval [CI]: 0.792-0.996) was significantly higher than CTA (AUC=0.685, 95% CI: 0.576-0.794) to detect FFR ≤0.8 (p=0.0021). Per-lesion specificity, sensitivity, and accuracy of LBM CT-FFR were 97.7%, 79.3%, and 90.4%, respectively. LBM CT-FFR has very good diagnostic accuracy to detect lesion-specific ischaemia (FFR ≤0.8) and can be performed in less than one hour.

  13. The list of official methods of laboratory diagnostics of foods and fodder crops dated as of January 9, 2004

    International Nuclear Information System (INIS)

    2004-01-01

    The Ministry of Agriculture of the Slovak Republic published approved method of laboratory diagnostics of foods and fodder crops. Chapter 13.1 contains determination of specific activity of radionuclides in homogenizable materials by methods of semiconductor gamma-spectrometry in the range 60 keV - 200 keV for standard geometry

  14. Newton's method for solving a quadratic matrix equation with special coefficient matrices

    International Nuclear Information System (INIS)

    Seo, Sang-Hyup; Seo, Jong Hyun; Kim, Hyun-Min

    2014-01-01

    We consider the iterative method for solving a quadratic matrix equation with special coefficient matrices which arises in the quasi-birth-death problem. In this paper, we show that the elementwise minimal positive solvents to quadratic matrix equations can be obtained using Newton's method. We also prove that the convergence rate of the Newton iteration is quadratic if the Fréchet derivative at the elementwise minimal positive solvent is nonsingular. However, if the Fréchet derivative is singular, the convergence rate is at least linear. Numerical experiments of the convergence rate are given.(This is summarized a paper which is to appear in Honam Mathematical Journal.)

  15. Advance in study of intelligent diagnostic method for nuclear power plant

    International Nuclear Information System (INIS)

    Zhou Gang; Yang Li

    2008-01-01

    The advance of research on the application of three types of intelligent diagnostic approach based on neural network (ANN), fuzzy logic and expert system to the operation status monitoring and fault diagnosis of nuclear power plant (NPP) was reviewed. The research status and characters on status monitoring and fault diagnosis approaches based on neural network, fuzzy logic and expert system for nuclear power plant were analyzed. The development trend of applied research on intelligent diagnostic approaches for nuclear power plant was explored. The analysis results show that the research achievements on intelligent diagnostic approaches based on fuzzy logic and expert system for nuclear power plant are not much relatively. The research of intelligent diagnostic approaches for nuclear power plant concentrate on the aspect of operation status monitoring and fault diagnosis based on neural networks for nuclear power plant. The advancing tendency of intelligent diagnostic approaches for nuclear power plant is the combination of various intelligent diagnostic approaches, the combination of neural network diagnostic approaches and other diagnostic approaches as well as multiple neural network diagnostic approaches. (authors)

  16. Type 2 Endoleaks: The Diagnostic Performance of Non-Specialized Readers on Arterial and Venous Phase Multi-Slice CT Angiography.

    Directory of Open Access Journals (Sweden)

    Richard Nolz

    Full Text Available To define the diagnostic precision of non-specialized readers in the detection of type 2 endoleaks (T2EL in arterial versus venous phase acquisitions, and to evaluate an approach for radiation dose reduction.The pre-discharge and final follow-up multi-slice CT angiographies of 167 patients were retrospectively analyzed. Image data were separated into an arterial and a venous phase reading set. Two radiology residents assessed the reading sets for the presence of a T2EL, feeding vessels, and aneurysm sac size. Findings were compared with a standard of reference established by two experts in interventional radiology. The effective dose was calculated.Overall, experts detected 131 T2ELs, and 331 feeding vessels in 334 examinations. Persistent T2ELs causing aneurysm sac growth > 5 mm were detected in 20 patients. Radiation in arterial and venous phases contributed to a mean of 58.6% and 39.0% of the total effective dose. Findings of reader 1 and 2 showed comparable sensitivities in arterial sets of 80.9 versus 85.5 (p = 0.09, and in venous sets of 73.3 versus 79.4 (p = 0.15, respectively. Reader 1 and 2 achieved a significant higher detection rate of feeding vessels with arterial compared to venous set (p = 0.04, p < 0.01. Both readers correctly identified T2ELs with growing aneurysm sac in all cases, independent of the acquisition phase.Arterial acquisitions enable non-specialized readers an accurate detection of T2ELs, and a significant better identification of feeding vessels. Based on our results, it seems reasonable to eliminate venous phase acquisitions.

  17. Accuracy of Diagnostic Methods and Surveillance Sensitivity for Human Enterovirus, South Korea, 1999–2011

    Science.gov (United States)

    Hyeon, Ji-Yeon; Hwang, Seoyeon; Kim, Hyejin; Song, Jaehyoung; Ahn, Jeongbae; Kang, Byunghak; Kim, Kisoon; Choi, Wooyoung; Chung, Jae Keun; Kim, Cheon-Hyun; Cho, Kyungsoon; Jee, Youngmee; Kim, Jonghyun; Kim, Kisang; Kim, Sun-Hee; Kim, Min-Ji

    2013-01-01

    The epidemiology of enteroviral infection in South Korea during 1999–2011 chronicles nationwide outbreaks and changing detection and subtyping methods used over the 13-year period. Of 14,657 patients whose samples were tested, 4,762 (32.5%) samples were positive for human enterovirus (human EV); as diagnostic methods improved, the rate of positive results increased. A seasonal trend of outbreaks was documented. Genotypes enterovirus 71, echovirus 30, coxsackievirus B5, enterovirus 6, and coxsackievirus B2 were the most common genotypes identified. Accurate test results correlated clinical syndromes to enterovirus genotypes: aseptic meningitis to echovirus 30, enterovirus 6, and coxsackievirus B5; hand, foot and mouth disease to coxsackievirus A16; and hand, foot and mouth disease with neurologic complications to enterovirus 71. There are currently no treatments specific to human EV infections; surveillance of enterovirus infections such as this study provides may assist with evaluating the need to research and develop treatments for infections caused by virulent human EV genotypes. PMID:23876671

  18. Diagnostic electrocardiography in epidemiological studies of Chagas' disease: multicenter evaluation of a standardized method

    Directory of Open Access Journals (Sweden)

    Lázzari Julio O.

    1998-01-01

    Full Text Available An electrocardiographic recording method with an associated reading guide, designed for epidemiological studies on Chagas' disease, was tested to assess its diagnostic reproducibility. Six cardiologists from five countries each read 100 electrocardiographic (ECG tracings, including 30 from chronic chagasic patients, then reread them after an interval of 6 months. The readings were blind, with the tracings numbered randomly for the first reading and renumbered randomly for the second reading. The physicians, all experienced in interpreting ECGs from chagasic patients, followed printed instructions for reading the tracings. Reproducibility of the readings was evaluated using the kappa (k index for concordance. The results showed a high degree of interobserver concordance with respect to the diagnosis of normal vs. abnormal tracings (k = 0.66; SE 0.02. While the interpretations of some categories of ECG abnormalities were highly reproducible, others, especially those having a low prevalence, showed lower levels of concordance. Intraobserver concordance was uniformly higher than interobserver concordance. The findings of this study justify the use by specialists of the recording of readings method proposed for epidemiological studies on Chagas' disease, but warrant caution in the interpretation of some categories of electrocardiographic alterations.

  19. Diagnostic electrocardiography in epidemiological studies of Chagas' disease: multicenter evaluation of a standardized method

    Directory of Open Access Journals (Sweden)

    Julio O. Lázzari

    1998-11-01

    Full Text Available An electrocardiographic recording method with an associated reading guide, designed for epidemiological studies on Chagas' disease, was tested to assess its diagnostic reproducibility. Six cardiologists from five countries each read 100 electrocardiographic (ECG tracings, including 30 from chronic chagasic patients, then reread them after an interval of 6 months. The readings were blind, with the tracings numbered randomly for the first reading and renumbered randomly for the second reading. The physicians, all experienced in interpreting ECGs from chagasic patients, followed printed instructions for reading the tracings. Reproducibility of the readings was evaluated using the kappa (k index for concordance. The results showed a high degree of interobserver concordance with respect to the diagnosis of normal vs. abnormal tracings (k = 0.66; SE 0.02. While the interpretations of some categories of ECG abnormalities were highly reproducible, others, especially those having a low prevalence, showed lower levels of concordance. Intraobserver concordance was uniformly higher than interobserver concordance. The findings of this study justify the use by specialists of the recording of readings method proposed for epidemiological studies on Chagas' disease, but warrant caution in the interpretation of some categories of electrocardiographic alterations.

  20. The nuclear interaction analysis methods for diagnostics of high power ion beam technologies

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhkov, V A; Grushin, I I; Remnev, G E [Nuclear Physics Inst., Tomsk (Russian Federation)

    1997-12-31

    The complex of Nuclear Interaction Analysis Methods including charged particle activation analysis (CPAA and HIAA), spectrometry of ion induced gamma-emission (PIGE and HIIGE) , characteristic X-ray emission (PIXE), and Rutherford Backscattering Spectrometry (RBS), have been used for diagnostics of the High Power Ion Beam (HPIB) assisted technologies. Accelerated ion beams from the EG-2.5 electrostatic generator and U-120 cyclotron were used for implementation of the techniques. The complex allows a lot of problems of elemental and isotopic analysis to be addressed. First, it is the determination of micro- and macrocomponents of modified materials; second, determination of surface density of thin films, multilayers and coatings, total surface gaseous contamination and amounts of the elements implanted in specimens; third, measurement of concentration depth profiles of the elements. Experiments have shown that the preferable application of nuclear analysis methods allows us to avoid the considerable errors arising when the concentration depth profiles of elements are measured by SIMS or AES in studies of mass transfer processes induced by HPIBs. (author). 1 tab., 2 figs., 3 refs.

  1. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    Science.gov (United States)

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  2. Diagnostic Performance of a Rapid Magnetic Resonance Imaging Method of Measuring Hepatic Steatosis

    Science.gov (United States)

    House, Michael J.; Gan, Eng K.; Adams, Leon A.; Ayonrinde, Oyekoya T.; Bangma, Sander J.; Bhathal, Prithi S.; Olynyk, John K.; St. Pierre, Tim G.

    2013-01-01

    Objectives Hepatic steatosis is associated with an increased risk of developing serious liver disease and other clinical sequelae of the metabolic syndrome. However, visual estimates of steatosis from histological sections of biopsy samples are subjective and reliant on an invasive procedure with associated risks. The aim of this study was to test the ability of a rapid, routinely available, magnetic resonance imaging (MRI) method to diagnose clinically relevant grades of hepatic steatosis in a cohort of patients with diverse liver diseases. Materials and Methods Fifty-nine patients with a range of liver diseases underwent liver biopsy and MRI. Hepatic steatosis was quantified firstly using an opposed-phase, in-phase gradient echo, single breath-hold MRI methodology and secondly, using liver biopsy with visual estimation by a histopathologist and by computer-assisted morphometric image analysis. The area under the receiver operating characteristic (ROC) curve was used to assess the diagnostic performance of the MRI method against the biopsy observations. Results The MRI approach had high sensitivity and specificity at all hepatic steatosis thresholds. Areas under ROC curves were 0.962, 0.993, and 0.972 at thresholds of 5%, 33%, and 66% liver fat, respectively. MRI measurements were strongly associated with visual (r2 = 0.83) and computer-assisted morphometric (r2 = 0.84) estimates of hepatic steatosis from histological specimens. Conclusions This MRI approach, using a conventional, rapid, gradient echo method, has high sensitivity and specificity for diagnosing liver fat at all grades of steatosis in a cohort with a range of liver diseases. PMID:23555650

  3. Modern methods of high-pressure fuel pump common rail power system diagnostics

    Directory of Open Access Journals (Sweden)

    Kyshchun В.

    2016-08-01

    Full Text Available We've considered high pressure fuel pumps design features and equipment for their diagnosis. It was noted that the reliability of the fuel elements Common Rail system primarily provide precision parts of the fuel equipment. As a consequence, the aim of study was comparative analysis and laborious of modern methods of the high pressure fuel pump diagnosing. In particular, the definition of a technical condition of the fuel pump was carried out using a special stand and by measuring the fuel pressure and duty cycle of the pressure regulator signal. As an object of our research we've chosen Bosch № 0445010008 fuel pump (from Mercedes Benz E320cdi in which the plunger pairs were changed alternately with different technical conditions. Preliminary fuel pump parameters were determined by hydraulic testing. Based on conducted experiments we've found out that fuel pressure measurement change method and the duty cycle of the pressure regulator signal at the starting and full load modes less laborious compared to the definition of a technical condition of the pump on the stand. The results of both methods of diagnosing confirmed identity of the fuel pumps.

  4. A novel method to assay special nuclear materials by measuring prompt neutrons from polarized photofission

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, J.M., E-mail: mueller@tunl.duke.edu [Triangle Universities Nuclear Laboratory, Durham, NC 27710 (United States); Department of Physics, Duke University, Durham, NC 27708 (United States); Ahmed, M.W. [Triangle Universities Nuclear Laboratory, Durham, NC 27710 (United States); Department of Physics, Duke University, Durham, NC 27708 (United States); Department of Mathematics and Physics, North Carolina Central University, Durham, NC 27707 (United States); Weller, H.R. [Triangle Universities Nuclear Laboratory, Durham, NC 27710 (United States); Department of Physics, Duke University, Durham, NC 27708 (United States)

    2014-08-01

    A novel method of measuring the enrichment of special nuclear material is presented. Recent photofission measurements using a linearly polarized γ-ray beam were performed on samples of {sup 232}Th, {sup 233,235,238}U, {sup 237}Np, and {sup 239,240}Pu. Prompt neutron polarization asymmetries, defined to be the difference in the prompt neutron yields parallel and perpendicular to the plane of beam polarization divided by their sum, were measured. It was discovered that the prompt neutron polarization asymmetries differed significantly depending on the sample. Prompt neutrons from photofission of even–even (non-fissile) targets had significant polarization asymmetries (∼0.2 to 0.5), while those from odd-A (generally fissile) targets had polarization asymmetries close to zero. This difference in the polarization asymmetries could be exploited to measure the fissile versus non-fissile content of special nuclear materials, and potentially to detect the presence of fissile material during active interrogation. The proposed technique, its expected performance, and its potential applicability are discussed.

  5. Experiences of parents of children with special needs at school entry: a mixed method approach.

    Science.gov (United States)

    Siddiqua, A; Janus, M

    2017-07-01

    The transition from pre-school to kindergarten can be complex for children who need special assistance due to mental or physical disabilities (children with 'special needs'). We used a convergent mixed method approach to explore parents' experiences with service provision as their children transitioned to school. Parents (including one grandparent) of 37 children aged 4 to 6 years completed measures assessing their perceptions of and satisfaction with services. Semi-structured interviews were also conducted with 10 parents to understand their experience with services. Post transition, parents reported lower perceptions of services and decreased satisfaction than pre-transition. The following themes emerged from the qualitative data: qualities of services and service providers, communication and information transfer, parent advocacy, uncertainty about services, and contrasts and contradictions in satisfaction. The qualitative findings indicate that parents were both satisfied and concerned with aspects of the post-transition service provision. While the quantitative results suggested that parents' experience with services became less positive after their children entered school, the qualitative findings illustrated the variability in parents' experiences and components of service provision that require improvements to facilitate a successful school entry. © 2017 John Wiley & Sons Ltd.

  6. A novel method to assay special nuclear materials by measuring prompt neutrons from polarized photofission

    International Nuclear Information System (INIS)

    Mueller, J.M.; Ahmed, M.W.; Weller, H.R.

    2014-01-01

    A novel method of measuring the enrichment of special nuclear material is presented. Recent photofission measurements using a linearly polarized γ-ray beam were performed on samples of 232 Th, 233,235,238 U, 237 Np, and 239,240 Pu. Prompt neutron polarization asymmetries, defined to be the difference in the prompt neutron yields parallel and perpendicular to the plane of beam polarization divided by their sum, were measured. It was discovered that the prompt neutron polarization asymmetries differed significantly depending on the sample. Prompt neutrons from photofission of even–even (non-fissile) targets had significant polarization asymmetries (∼0.2 to 0.5), while those from odd-A (generally fissile) targets had polarization asymmetries close to zero. This difference in the polarization asymmetries could be exploited to measure the fissile versus non-fissile content of special nuclear materials, and potentially to detect the presence of fissile material during active interrogation. The proposed technique, its expected performance, and its potential applicability are discussed

  7. The Accuracy of Diagnostic Methods for Diabetic Retinopathy: A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Vicente Martínez-Vizcaíno

    Full Text Available The objective of this study was to evaluate the accuracy of the recommended glycemic measures for diagnosing diabetic retinopathy.We systematically searched MEDLINE, EMBASE, the Cochrane Library, and the Web of Science databases from inception to July 2015 for observational studies comparing the diagnostic accuracy of glycated hemoglobin (HbA1c, fasting plasma glucose (FPG, and 2-hour plasma glucose (2h-PG. Random effects models for the diagnostic odds ratio (dOR value computed by Moses' constant for a linear model and 95% CIs were used to calculate the accuracy of the test. Hierarchical summary receiver operating characteristic curves (HSROC were used to summarize the overall test performance.Eleven published studies were included in the meta-analysis. The pooled dOR values for the diagnosis of retinopathy were 16.32 (95% CI 13.86-19.22 for HbA1c and 4.87 (95% CI 4.39-5.40 for FPG. The area under the HSROC was 0.837 (95% CI 0.781-0.892 for HbA1c and 0.735 (95% CI 0.657-0.813 for FPG. The 95% confidence region for the point that summarizes the overall test performance of the included studies occurs where the cut-offs ranged from 6.1% (43.2 mmol/mol to 7.8% (61.7 mmol/mol for HbA1c and from 7.8 to 9.3 mmol/L for FPG. In the four studies that provided information regarding 2h-PG, the pooled accuracy estimates for HbA1c were similar to those of 2h-PG; the overall performance for HbA1c was superior to that for FPG.The three recommended tests for the diagnosis of type 2 diabetes in nonpregnant adults showed sufficient accuracy for their use in clinical settings, although the overall accuracy for the diagnosis of retinopathy was similar for HbA1c and 2h-PG, which were both more accurate than for FPG. Due to the variability and inconveniences of the glucose level-based methods, HbA1c appears to be the most appropriate method for the diagnosis diabetic retinopathy.

  8. A quantitative analysis of Tl-201 myocardial perfusion image with special reference to circumferential profile method

    International Nuclear Information System (INIS)

    Miyanaga, Hajime

    1982-01-01

    A quantitative analysis of thallium-201 myocardial perfusion image (MPI) was attempted by using circumferential profile method (CPM) and the first purpose of this study is to assess the clinical utility of this method for the detection of myocardial ischemia. In patients with coronary artery disease, CPM analysis to exercise T1-MPI showed high sensitivity (9/12, 75%) and specificity (9/9, 100%), whereas exercise ECG showed high sensitivity (9/12, 75%), but relatively low specificity (7/9, 78%). In patients with myocardial infarction, CPM also showed high sensitivity (34/38, 89%) for the detection of myocardial necrosis, compared with visual interpretation (31/38, 81%) and with ECG (31/38, 81%). Defect score was correlated well with the number of abnormal Q waves. In exercise study, CPM was also sensitive to the change of perfusion defect in T1-MPI produced by exercise. So the results indicate that CPM is a good method not only quantitatively but also objectively to analyze T1-MPI. Although ECG is the most commonly used diagnostic tool for ischemic heart disease, several exercise induced ischemic changes in ECG have been still on discussion as criteria. So the second purpose of this study is to evaluate these ischemic ECG changes by exercise T1-MPI analized quantitatively. ST depression (ischemic 1 mm and junctional 2 mm or more), ST elevation (1 mm or more), and coronary T wave reversion in exercise ECG were though to be ischemic changes. (J.P.N.)

  9. Quantitative analysis of Tl-201 myocardial perfusion image with special reference to circumferential profile method

    Energy Technology Data Exchange (ETDEWEB)

    Miyanaga, Hajime [Kyoto Prefectural Univ. of Medicine (Japan)

    1982-08-01

    A quantitative analysis of thallium-201 myocardial perfusion image (MPI) was attempted by using circumferential profile method (CPM) and the first purpose of this study is to assess the clinical utility of this method for the detection of myocardial ischemia. In patients with coronary artery disease, CPM analysis to exercise T1-MPI showed high sensitivity (9/12, 75%) and specificity (9/9, 100%), whereas exercise ECG showed high sensitivity (9/12, 75%), but relatively low specificity (7/9, 78%). In patients with myocardial infarction, CPM also showed high sensitivity (34/38, 89%) for the detection of myocardial necrosis, compared with visual interpretation (31/38, 81%) and with ECG (31/38, 81%). Defect score was correlated well with the number of abnormal Q waves. In exercise study, CPM was also sensitive to the change of perfusion defect in T1-MPI produced by exercise. So the results indicate that CPM is a good method not only quantitatively but also objectively to analyze T1-MPI. Although ECG is the most commonly used diagnostic tool for ischemic heart disease, several exercise induced ischemic changes in ECG have been still on discussion as criteria. So the second purpose of this study is to evaluate these ischemic ECG changes by exercise T1-MPI analized quantitatively. ST depression (ischemic 1 mm and junctional 2 mm or more), ST elevation (1 mm or more), and coronary T wave reversion in exercise ECG were though to be ischemic changes.

  10. The Combine Use of Semi-destructive and Non-destructive Methods for Tiled Floor Diagnostics

    Science.gov (United States)

    Štainbruch, Jakub; Bayer, Karol; Jiroušek, Tomáš; Červinka, Josef

    2017-04-01

    The combination of semi-destructive and non-destructive methods was used to asset the conditions of a tiled floor in the historical monument Minaret, situated in the park complex of the Chateau Lednice (South Moravia Region, Czech Republic), before its renovation. Another set of measurements is going to be performed after the conservation works are finished. (The comparison of the results collected during pre- and post-remediation measurements will be known and presented during the General Assembly meeting in Wien.) The diagnostic complex of methods consisted of photogrammetry, resistivity drilling and georadar. The survey was aimed to contour extends of air gaps beneath the tiles and the efficiency of filling gaps by means of injection, consolidation and gluing individual layers. The state chateau Lednice creates a part of the Lednice-Valtice precinct, a UNESCO landmark, and belongs among the greatest historic monuments in Southern Moravia. In the chateau park there is a romantic observation tower in the shape of a minaret built according to the plans of Josef Hardtmuth between 1798-1804. The Minaret has been extensively renovated for many decades including the restoration of mosaic floors from Venetian terazzo. During the static works of the Minaret building between 1999-2000, the mosaic floors in the rooms on the second floor were transferred and put back onto concrete slabs. Specifically, the floor was cut up to tiles and these were glued to square slabs which were then attached to the base plate. The transfer was not successful and the floor restoration was finalized between 2016-2017. The damage consisted in separating the original floor from the concrete plate which led to creating gaps. Furthermore, the layers of the floor were not compact. It was necessary to fill the gaps and consolidate and glue the layers. The existence of air gap between individual layers of the tiles and their degradation was detected using two different diagnostic methods: semi

  11. A Special Variant of the Moment Method for Fredholm Integral Equations of the Second Kind

    Directory of Open Access Journals (Sweden)

    S. A. Solov’eva

    2015-01-01

    Full Text Available We consider the linear Fredholm integral equation of the second kind, where the kernel and the free term are smooth functions. We find the unknown function in this class as well.Exact and approximate methods for the solution of linear Fredholm integral equations of the second kind are well developed. However, classical methods do not take into account the structural properties of the kernel and the free term of equation.In this paper we develop and justify a special variant of the moment method to solve this equation, which takes into account the differential properties of initial data. The proposed paper furthers studies of N.S Gabbasov, I.P. Kasakina, and S.A Solov’eva. We use approximation theory, version of the general theory of approximate methods of analysis that Gabdulkhayev B.G suggested, and methods of functional analysis to prove theorems. In addition, we use N.S. Gabbasov’s ideas and methods in papers that are devoted to the Fredholm equations of the first kind, as well as N.S. Gabbasov and S.A Solov’eva’s investigations on the Fredholm equations of the third kind in the space of distributions.The first part of the paper provides a description of the basic function space and elements of the theory of approximation in it.In the second part we propose and theoretically justify a generalized moment method. We have demonstrated that the improvement of differential properties of the initial data improves the approximation accuracy. Since, in practice, the approximate equations are solved, as a rule, only approximately, we prove the stability and causality of the proposed method. The resulting estimate of the paper is in good agreement with the estimate for the ordinary moment method for equations of the second kind in the space of continuous functions.In the final section we have shown that a developed method is optimal in order of accuracy among all polynomial projection methods to solve Fredholm integral equations of the second

  12. Comparison of diagnostic methods to detect Histoplasma capsulatum in serum and blood samples from AIDS patients

    Science.gov (United States)

    da Silva, Marcos Vinicius; Criado, Paulo Ricardo; Luiz, Olinda do Carmo; Vicentini, Adriana Pardini

    2018-01-01

    Background Although early and rapid detection of histoplasmosis is essential to prevent morbidity and mortality, few diagnostic tools are available in resource-limited areas, especially where it is endemic and HIV/AIDS is also epidemic. Thus, we compared conventional and molecular methods to detect Histoplasma capsulatum in sera and blood from HIV/AIDS patients. Methodology We collected a total of 40 samples from control volunteers and patients suspected of histoplasmosis, some of whom were also infected with other pathogens. Samples were then analyzed by mycological, serological, and molecular methods, and stratified as histoplasmostic with (group I) or without AIDS (group II), uninfected (group III), and infected with HIV and other pathogens only (group IV). All patients were receiving treatment for histoplasmosis and other infections at the time of sample collection. Results Comparison of conventional methods with nested PCR using primers against H. capsulatum 18S rRNA (HC18S), 5.8S rRNA ITS (HC5.8S-ITS), and a 100 kDa protein (HC100) revealed that sensitivity against sera was highest for PCR with HC5.8S-ITS, followed by immunoblotting, double immunodiffusion, PCR with HC18S, and PCR with HC100. Specificity was equally high for double immunodiffusion, immunoblotting and PCR with HC100, followed for PCR with HC18S and HC5.8-ITS. Against blood, sensitivity was highest for PCR with HC5.8S-ITS, followed by PCR with HC18S, Giemsa staining, and PCR with HC100. Specificity was highest for Giemsa staining and PCR with HC100, followed by PCR with HC18S and HC5.8S-ITS. PCR was less efficient in patients with immunodeficiency due to HIV/AIDS and/or related diseases. Conclusion Molecular techniques may detect histoplasmosis even in cases with negative serology and mycology, potentially enabling early diagnosis. PMID:29342162

  13. Comparison of diagnostic methods to detect Histoplasma capsulatum in serum and blood samples from AIDS patients.

    Directory of Open Access Journals (Sweden)

    Katia Cristina Dantas

    Full Text Available Although early and rapid detection of histoplasmosis is essential to prevent morbidity and mortality, few diagnostic tools are available in resource-limited areas, especially where it is endemic and HIV/AIDS is also epidemic. Thus, we compared conventional and molecular methods to detect Histoplasma capsulatum in sera and blood from HIV/AIDS patients.We collected a total of 40 samples from control volunteers and patients suspected of histoplasmosis, some of whom were also infected with other pathogens. Samples were then analyzed by mycological, serological, and molecular methods, and stratified as histoplasmostic with (group I or without AIDS (group II, uninfected (group III, and infected with HIV and other pathogens only (group IV. All patients were receiving treatment for histoplasmosis and other infections at the time of sample collection.Comparison of conventional methods with nested PCR using primers against H. capsulatum 18S rRNA (HC18S, 5.8S rRNA ITS (HC5.8S-ITS, and a 100 kDa protein (HC100 revealed that sensitivity against sera was highest for PCR with HC5.8S-ITS, followed by immunoblotting, double immunodiffusion, PCR with HC18S, and PCR with HC100. Specificity was equally high for double immunodiffusion, immunoblotting and PCR with HC100, followed for PCR with HC18S and HC5.8-ITS. Against blood, sensitivity was highest for PCR with HC5.8S-ITS, followed by PCR with HC18S, Giemsa staining, and PCR with HC100. Specificity was highest for Giemsa staining and PCR with HC100, followed by PCR with HC18S and HC5.8S-ITS. PCR was less efficient in patients with immunodeficiency due to HIV/AIDS and/or related diseases.Molecular techniques may detect histoplasmosis even in cases with negative serology and mycology, potentially enabling early diagnosis.

  14. Studying Teaching Methods, Strategies and Best Practices for Young Children with Special Educational Needs

    Science.gov (United States)

    Tzivinikou, S.; Papoutsaki, K.

    2016-01-01

    Teaching objectives in special education are different from those in the ordinary classroom. Educational programmes for special needs students are focused on individual learning, achievement and progress. Thus, the instruction in special education classrooms and resource rooms in inclusive schools has to be specific, directed and individualised.…

  15. The modern methods of treatment of patients with radiation syndrome in a specialized hospital (analytical review)

    International Nuclear Information System (INIS)

    Selidovkin, G.D.

    1995-01-01

    Modern methods of treatment of patients with various symptoms of acute radiation disease in a specialized hospital are reviewed. The treatment starts from prophylactic prescription of antibacterial antibiotics of latest generations (imipinem, cephalosporin of 3-rd generation), antifungal and antiviral remedies, immunoglobulin G, selective decontamination of intestines should be carried out. Transfusion of donor thrombocytes and erythrocytes in the quantities adequate to the degree of explicit cytopenia should be provided. Full parenteral feeding should be prescribed, desintoxication and adjustment therapy is be administered. Transplantation of HLA-identical bone marrow may be recommended only over the range from 10 to 15 Gy close to uniform irradiation. The most promising in the therapy of acute radiation disease - 3, 4 are hemopoietic growth factors. 76 refs.; 2 tabs

  16. Methods of sociological diagnostics in the assessment of staff's competencies: a case of a state museum (St. Petersburg, Russia

    Directory of Open Access Journals (Sweden)

    Asiia Usiaeva

    2016-01-01

    Full Text Available The study is dedicated to research of methods of sociological diagnostics, which can be used in the assessment of staff's competencies. Theoretical framework of this survey is T. Parson’s structural functionalism, the approach that sees the society as a complex system. The research questions were how we can analyze competencies by using sociological diagnostics and what the features of sociological diagnostics are. In order to achieve the target, it was analyzed the assessment of staff's competencies in the museum complex “The Cathedral”, Saint-Petersburg, Russia. Methodology of the research was structured observation, data collected by using “Mystery shopper” method. As a result, it was showed which techniques were applied in the staff’s assessment in this museum. Besides, the researcher discovered the level of museum staff’s competencies and revealed that the least developed employees’ competence was communication with visitors.

  17. The stepchild of intestinal diagnostics. Evaluation of radiological methods to diagnose leiomyomas of the small bowel

    International Nuclear Information System (INIS)

    Keberle, M.; Wittenberg, G.; Jenett, M.; Hahn, D.; Mueller, J.G.

    1998-01-01

    Purpose: Various radiological methods to diagnose small bowel neoplasmas and problems of differential diagnosis specially considerating leiomyomas are discussed. Patients and methods: Two patients with leiomyoma of the ileum underwent enteroclysis, computed tomography of the abdomen, intra-arterial DSA and colour Doppler sonography. Another patient with leiomyosarcoma just underwent CT of the abdomen with CT-guided biopsy. Results: Due to the homogenous density and the smooth surface of the tumors in computed tomography and respectively enteroclysis and the presentation of the tumor vascularisation in the angiography and Colour Doppler sonography in both patients a leiomyoma of the small bowel was diagnosed. Postoperatively this diagnosis was histologically confirmed. The CT-findings of the patient with leiomyosarcoma were not suspicious of a malignant tumor. Conclusion: Radiologically it is not possible to determine the dignity of smooth muscle cell tumors safely. That is the reason why the diagnosis has to be achieved operatively. But the histopathological diagnosis based on the mitotic rate may be difficult. Therefore the after care has to be carried out thoroughly. (orig.) [de

  18. Detecting Renibacterium salmoninarum in wild brown trout by use of multiple organ samples and diagnostic methods

    Science.gov (United States)

    Guomundsdottir, S.; Applegate, Lynn M.; Arnason, I.O.; Kristmundsson, A.; Purcell, Maureen K.; Elliott, Diane G.

    2017-01-01

    Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease (BKD), is endemic in many wild trout species in northerly regions. The aim of the present study was to determine the optimal R. salmoninarum sampling/testing strategy for wild brown trout (Salmo trutta L.) populations in Iceland. Fish were netted in a lake and multiple organs—kidney, spleen, gills, oesophagus and mid-gut—were sampled and subjected to five detection tests i.e. culture, polyclonal enzyme-linked immunosorbent assay (pELISA) and three different PCR tests. The results showed that each fish had encountered R. salmoninarum but there were marked differences between results obtained depending on organ and test. The bacterium was not cultured from any kidney sample while all kidney samples were positive by pELISA. At least one organ from 92.9% of the fish tested positive by PCR. The results demonstrated that the choice of tissue and diagnostic method can dramatically influence the outcome of R. salmoninarum surveys.

  19. Development of a diagnostic expert system for eddy current data analysis using applied artificial intelligence methods

    International Nuclear Information System (INIS)

    Upadhyaya, B.R.; Yan, W.; Henry, G.

    1999-01-01

    A diagnostic expert system that integrates database management methods, artificial neural networks, and decision-making using fuzzy logic has been developed for the automation of steam generator eddy current test (ECT) data analysis. The new system, known as EDDYAI, considers the following key issues: (1) digital eddy current test data calibration, compression, and representation; (2) development of robust neural networks with low probability of misclassification for flaw depth estimation; (3) flaw detection using fuzzy logic; (4) development of an expert system for database management, compilation of a trained neural network library, and a decision module; and (5) evaluation of the integrated approach using eddy current data. The implementation to field test data includes the selection of proper feature vectors for ECT data analysis, development of a methodology for large eddy current database management, artificial neural networks for flaw depth estimation, and a fuzzy logic decision algorithm for flaw detection. A large eddy current inspection database from the Electric Power Research Institute NDE Center is being utilized in this research towards the development of an expert system for steam generator tube diagnosis. The integration of ECT data pre-processing as part of the data management, fuzzy logic flaw detection technique, and tube defect parameter estimation using artificial neural networks are the fundamental contributions of this research. (orig.)

  20. Development of a diagnostic expert system for eddy current data analysis using applied artificial intelligence methods

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyaya, B.R.; Yan, W. [Tennessee Univ., Knoxville, TN (United States). Dept. of Nuclear Engineering; Behravesh, M.M. [Electric Power Research Institute, Palo Alto, CA (United States); Henry, G. [EPRI NDE Center, Charlotte, NC (United States)

    1999-09-01

    A diagnostic expert system that integrates database management methods, artificial neural networks, and decision-making using fuzzy logic has been developed for the automation of steam generator eddy current test (ECT) data analysis. The new system, known as EDDYAI, considers the following key issues: (1) digital eddy current test data calibration, compression, and representation; (2) development of robust neural networks with low probability of misclassification for flaw depth estimation; (3) flaw detection using fuzzy logic; (4) development of an expert system for database management, compilation of a trained neural network library, and a decision module; and (5) evaluation of the integrated approach using eddy current data. The implementation to field test data includes the selection of proper feature vectors for ECT data analysis, development of a methodology for large eddy current database management, artificial neural networks for flaw depth estimation, and a fuzzy logic decision algorithm for flaw detection. A large eddy current inspection database from the Electric Power Research Institute NDE Center is being utilized in this research towards the development of an expert system for steam generator tube diagnosis. The integration of ECT data pre-processing as part of the data management, fuzzy logic flaw detection technique, and tube defect parameter estimation using artificial neural networks are the fundamental contributions of this research. (orig.)

  1. Development of precise measurement method of neutron energy for plasma temperature diagnostics in thermonuclear fusion

    International Nuclear Information System (INIS)

    Mori, Chizuo; Gotoh, Junichi; Uritani, Akira; Miyahara, Hiroshi; Ikeda, Yuichiro; Kasugai, Yoshimi; Kaneko, Junichi

    1998-01-01

    There are many types of fast neutron spectrometers for plasma temperature diagnostics, 28 Si(n,α) 25 Mg reaction giving the energy resolution of 2.2% for 14 MeV neutrons, the 12 C(n,α) 9 Be reaction giving the resolution of 2.15%. These detectors, however suffer from radiation damage, which demands to exchange the detector to a new one in every a few month depending on the usage. Recoil proton method has also been developed by using liquid scintillator or plastic scintillator, as a neutron-to-proton converter in front of a Si-detector, which is called counter telescope type, giving a resolution of 4.0%. This type of spectrometer can reduce radiation damage by placing Si-detector at outside Neutron beam. The scintillator can measure the lost energy of protons in the converter (i.e. the scintillator) and the measured energy loss can be used for improving the energy resolution. However, the energy resolution of organic scintillator itself is generally not so good. We proposed to use a proportional counter with CH 4 as counting gas and also as a neutron-proton converter, which has far better energy resolution than plastic scintillators, although the time resolution of counting in proportional counters is generally inferior to that in organic scintillation counters. The characteristics of the new spectrometer were experimentally studied and also were simulated with analytical calculation. (author)

  2. Studies of renal parenchymal impairments with extracorporeal shock wave lithotripsy (ESWL) by diagnostic imaging methods

    Energy Technology Data Exchange (ETDEWEB)

    Ohishi, Yukihiko; Machida, Toyohei; Tashiro, Kazuya; Wada, Tetsuro; Mochizuki, Atsushi; Torii, Shinichiro; Yoshigoe, Fukuo; Kawashima, Yoshio; Asano, Koji (Jikei Univ., Tokyo (Japan). School of Medicine)

    1989-05-01

    Renal parenchymal impairments with extracorporeal shock wave lithotripsy (ESWL) were studied by diagnostic imaging methods. The subjects were 25 patients with renal stones, and EDAP LT-01 (piezoelectric system) was used for the equipment of ESWL. The examination by MRI, X-ray CT and /sup 99m/Tc-DMSA scintigraphy using SPECT were performed before and after ESWL. To the 24 kidneys of 12 adult dogs, shock waves were fired in order to examine the experimental renal parenchymal impairments. After the treatment with ESWL, renal abnormal findings were obtained with MRI in 6 patients out of 11 (54.5%), with X-ray CT in 1 patient out of 12 (8.3%), and with the /sup 99m/Tc-DMSA renal scintigraphy in 4 patients out of 6 (66.7%). In the inspections with X-ray CT and renal scintigraphy conducted in 4 weeks, it was noted that the conditions of patients were recovered to the states before ESWL was performed. Using the therapeutic doses of shock wave for humans, the renal parenchymal impairments in the kidney in dogs were normalized in 7 days. Although it has been considered that the degree of renal parenchymal impairments with ESWL treatment may be influenced by the kind of the equipment, frequency of shock waves and their strength, the extent of impairments were rather mild, and it was presumed that the impairments might be recovered on the images in 3 to 4 weeks at the latest. (author).

  3. Studies of renal parenchymal impairments with extracorporeal shock wave lithotripsy (ESWL) by diagnostic imaging methods

    International Nuclear Information System (INIS)

    Ohishi, Yukihiko; Machida, Toyohei; Tashiro, Kazuya; Wada, Tetsuro; Mochizuki, Atsushi; Torii, Shinichiro; Yoshigoe, Fukuo; Kawashima, Yoshio; Asano, Koji

    1989-01-01

    Renal parenchymal impairments with extracorporeal shock wave lithotripsy (ESWL) were studied by diagnostic imaging methods. The subjects were 25 patients with renal stones, and EDAP LT-01 (piezoelectric system) was used for the equipment of ESWL. The examination by MRI, X-ray CT and 99m Tc-DMSA scintigraphy using SPECT were performed before and after ESWL. To the 24 kidneys of 12 adult dogs, shock waves were fired in order to examine the experimental renal parenchymal impairments. After the treatment with ESWL, renal abnormal findings were obtained with MRI in 6 patients out of 11 (54.5%), with X-ray CT in 1 patient out of 12 (8.3%), and with the 99m Tc-DMSA renal scintigraphy in 4 patients out of 6 (66.7%). In the inspections with X-ray CT and renal scintigraphy conducted in 4 weeks, it was noted that the conditions of patients were recovered to the states before ESWL was performed. Using the therapeutic doses of shock wave for humans, the renal parenchymal impairments in the kidney in dogs were normalized in 7 days. Although it has been considered that the degree of renal parenchymal impairments with ESWL treatment may be influenced by the kind of the equipment, frequency of shock waves and their strength, the extent of impairments were rather mild, and it was presumed that the impairments might be recovered on the images in 3 to 4 weeks at the latest. (author)

  4. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 16

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, Imre; Dykin, Victor; Jonsson, Anders; Demaziere, Christophe (Chalmers Univ. of Technology, Dept. of Nuclear Engineering, Goeteborg (Sweden))

    2010-12-15

    This report gives an account of the work performed by the Dept. of Nuclear Engineering, Chalmers Univ. of Technology, in the frame of a research contract with the Swedish Radiation Safety Authority (SSM), contract No. SSM 2009/2093. The present report is based on work performed by Imre Pazsit, Victor Dykin, Anders Jonsson and Christophe Demaziere, with Imre Pazsit being the project leader. This report describes the results obtained during Stage 16 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of Stage 1 and 2 (SKI Report 95:14 and 96:50, Pazsit et al. 1995, 1996). Results up to Stage 15 were reported in (Pazsit et al. 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2003a, 2003b; Demaziere et al, 2004; Sunde et al, 2006; Pazsit et al. 2008, 2009). A brief proposal for the continuation of this program in Stage 17 is also given at the end of the report. The program executed in Stage 16 consists of four parts as follows: - An overview of the present status of experience with BWR stability; - An investigation of the significance of the properties of the noise source for BWR instability; - Study of the dynamics of molten salt systems: construction of the adjoint and calculating the space dependent noise induced by propagating perturbations in the fuel; - A specific study of some novel methods of analysis of non-linear and non-stationary processes

  5. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods, Stage 16

    International Nuclear Information System (INIS)

    Pazsit, Imre; Dykin, Victor; Jonsson, Anders; Demaziere, Christophe

    2010-12-01

    This report gives an account of the work performed by the Dept. of Nuclear Engineering, Chalmers Univ. of Technology, in the frame of a research contract with the Swedish Radiation Safety Authority (SSM), contract No. SSM 2009/2093. The present report is based on work performed by Imre Pazsit, Victor Dykin, Anders Jonsson and Christophe Demaziere, with Imre Pazsit being the project leader. This report describes the results obtained during Stage 16 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of Stage 1 and 2 (SKI Report 95:14 and 96:50, Pazsit et al. 1995, 1996). Results up to Stage 15 were reported in (Pazsit et al. 1995, 1996, 1997, 1998, 1999, 2000, 2001, 2003a, 2003b; Demaziere et al, 2004; Sunde et al, 2006; Pazsit et al. 2008, 2009). A brief proposal for the continuation of this program in Stage 17 is also given at the end of the report. The program executed in Stage 16 consists of four parts as follows: - An overview of the present status of experience with BWR stability; - An investigation of the significance of the properties of the noise source for BWR instability; - Study of the dynamics of molten salt systems: construction of the adjoint and calculating the space dependent noise induced by propagating perturbations in the fuel; - A specific study of some novel methods of analysis of non-linear and non-stationary processes

  6. Introduction to the Special Issue on Advancing Methods for Analyzing Dialect Variation.

    Science.gov (United States)

    Clopper, Cynthia G

    2017-07-01

    Documenting and analyzing dialect variation is traditionally the domain of dialectology and sociolinguistics. However, modern approaches to acoustic analysis of dialect variation have their roots in Peterson and Barney's [(1952). J. Acoust. Soc. Am. 24, 175-184] foundational work on the acoustic analysis of vowels that was published in the Journal of the Acoustical Society of America (JASA) over 6 decades ago. Although Peterson and Barney (1952) were not primarily concerned with dialect variation, their methods laid the groundwork for the acoustic methods that are still used by scholars today to analyze vowel variation within and across languages. In more recent decades, a number of methodological advances in the study of vowel variation have been published in JASA, including work on acoustic vowel overlap and vowel normalization. The goal of this special issue was to honor that tradition by bringing together a set of papers describing the application of emerging acoustic, articulatory, and computational methods to the analysis of dialect variation in vowels and beyond.

  7. Non invasive diagnostic methods for better screening of peripheral arterial disease.

    Science.gov (United States)

    Nirala, Neelamshobha; Periyasamy, R; Kumar, Awanish

    2018-05-16

    Peripheral arterial disease (PAD) is a common circulatory problem in which narrowed arteries reduce blood flow to extremities usually legs. It does not receive enough blood flow to keep up with demand. This causes symptoms, most notably leg pain while walking which is known as claudication. It is a common manifestation of type II Diabetes, but the relationship between other vascular diseases and lower limb (LL)-PAD has been poorly understood and investigated. When assessing a patient with clinically LLPAD, two questions are in order to establish a diagnosis: one is non-invasive testing and other is invasive. Invasive methods are painful and get so bad that some people need to have a leg surgery. People with Diabetes are at increased risk for amputation and it is used only when the damage is very severe. Diagnosis of LLPAD begins with a physical examination, patient history, certain questionnaire and non invasive mode of diagnosis is started for the screening of patients. Clinicians check for weak pulses in the legs and then decide for further diagnosis. Paper discusses the prevalence of LLPAD worldwide and in India along with the clinical effectiveness and limitations of these methods in case of Diabetes. The focus of this review is to discuss only those non invasive methods which are widely used for screening of LLPAD like Ankle brachial index (ABI), Toe brachial Index (TBI), and use of photoplethysmogram (PPG) specially in case of Diabetic patients. Also, this paper gives an overview of the work done using ABI, TBI, and PPG for detection of LLPAD. These tests are not painful and could be performed in a cost-effective manner to avoid delays in screening/diagnosis and also reduce costs. Copyright © 2018. Published by Elsevier Inc.

  8. Development of Monitoring and Diagnostic Methods for Robots Used In Remediation of Waste Sites - Final Report

    International Nuclear Information System (INIS)

    Martin, M.

    2000-01-01

    This project is the first evaluation of model-based diagnostics to hydraulic robot systems. A greater understanding of fault detection for hydraulic robots has been gained, and a new theoretical fault detection model developed and evaluated

  9. Pepper-pot diagnostic method to define emittance and Twiss parameters on low energies accelerators

    CERN Document Server

    Dolinska, M E

    2002-01-01

    The new complex mathematical algorithm to determine beam transverse emittance data and the Twiss parameters from intensity measured with pepper-por diagnostic device on rf low energies accelerators is described.

  10. Development of a benchtop baking method for chemically leavened crackers. I. Identification of a diagnostic formula and procedure

    Science.gov (United States)

    A benchtop baking method has been developed to predict the contribution of gluten functionality to overall flour performance for chemically leavened crackers. In order to identify a diagnostic cracker formula, the effects of leavening system (sodium bicarbonate, monocalcium phosphate, and ammonium b...

  11. Combating stress risks with the job stress self diagnostic method: paper XV World Congress of Sociology 2002

    NARCIS (Netherlands)

    Oeij, P.R.A.

    2002-01-01

    In this paper of the World Congress of Sociology 2002 of ISA (International Sociological Association), the content and uses of the Job Stress Self Diagnostic Method (JSSDM) are described. The JSSDM aim is (a) to diagnose work processes to determine the presence of conditions for control problems and

  12. THE SIMULATION DIAGNOSTIC METHODS AND REGENERATION WAYS OF REINFORCED - CONCRETE CONSTRUCTIONS OF BRIDGES IN PROVIDING THEIR OPERATING RELIABILITY AND LONGEVITY

    Directory of Open Access Journals (Sweden)

    B. V. Savchinskiy

    2010-03-01

    Full Text Available On the basis of analysis of existing diagnostic methods and regeneration ways of reinforced-concrete constructions of bridges the recommendations on introduction of new modern technologies of renewal of reinforced-concrete constructions of bridges in providing their operating reliability and longevity are offered.

  13. THE SIMULATION DIAGNOSTIC METHODS AND REGENERATION WAYS OF REINFORCED - CONCRETE CONSTRUCTIONS OF BRIDGES IN PROVIDING THEIR OPERATING RELIABILITY AND LONGEVITY

    OpenAIRE

    B. V. Savchinskiy

    2010-01-01

    On the basis of analysis of existing diagnostic methods and regeneration ways of reinforced-concrete constructions of bridges the recommendations on introduction of new modern technologies of renewal of reinforced-concrete constructions of bridges in providing their operating reliability and longevity are offered.

  14. Farm-level risk factors for Fasciola hepatica infection in Danish dairy cattle as evaluated by two diagnostic methods

    DEFF Research Database (Denmark)

    Takeuchi-Storm, Nao; Denwood, Matthew; Hansen, Tina Vicky Alstrup

    2017-01-01

    ) as a tool for diagnosis in Danish dairy cattle farms was assessed. This case-control study aimed to identify farm-level risk factors for fasciolosis in Danish dairy farms (> 50 animals slaughtered in 2013) using two diagnostic methods: recordings of liver condemnation at slaughter, and farm-level Fasciola...

  15. Comparison of selected diagnostic methods for identification of Cryptosporidium parvum and Cryptosporidium andersoni in routine examination of faeces

    Czech Academy of Sciences Publication Activity Database

    Kváč, Martin; Květoňová, Dana; Půžová, Gabriela; Ditrich, Oleg

    2003-01-01

    Roč. 50, č. 8 (2003), s. 405-411 ISSN 0931-1793 R&D Projects: GA AV ČR IBS6022006 Institutional research plan: CEZ:AV0Z6022909 Keywords : cryptosporidiosis * diagnostic methods * cattle Subject RIV: DJ - Water Pollution ; Quality Impact factor: 0.656, year: 2003

  16. Diagnostics of Technical Condition of Gear Units of Belt Conveyors for the Aggregate of Methods of Nondestructive Testing

    Science.gov (United States)

    Kuzin, Evgeny G.; Gerike, Boris L.; Drozdenko, Yuriy V.; Lupiy, Michael G.; Grigoryeva, Natalya V.

    2017-10-01

    The article reviews the issues of complex use of methods of technical diagnostics of gearboxes for belt conveyors, with the aim of creating an effective system of maintenance. The article is showing the results of the evaluation of the technical condition of the drives of belt conveyors based on vibration monitoring and thermal parameters, and analysis of lubricating oil.

  17. Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection

    OpenAIRE

    Lau, Han Yih; Botella, Jose R.

    2017-01-01

    Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care di...

  18. Non-invasive diagnostic methods for atherosclerosis and use in assessing progression and regression in hypercholesterolemia

    International Nuclear Information System (INIS)

    Tsushima, Motoo; Fujii, Shigeki; Yutani, Chikao; Yamamoto, Akira; Naitoh, Hiroaki.

    1990-01-01

    We evaluated the wall thickening and stenosis rate (ASI), the calcification rate (ACI), and the wall thickening and calcification stenosis rate (SCI) of the lower abdominal aorta calculated by the 12 sector method from simple or enhanced computed tomography. The intra-observer variation of the calculation of ASI was 5.7% and that of ACI was 2.4%. In 9 patients who underwent an autopsy examination, ACI was significantly correlated with the rate of the calcification dimension to the whole objective area of the abdominal aorta (r=0.856, p<0.01). However, there were no correlations between ASI and the surface involvement or the atherosclerotic index obtained by the point-counting method of the autopsy materials. In the analysis of 40 patients with atherosclerotic vascular diseases, ASI and ACI were also highly correlated with the percentage volume of the arterial wall in relation to the whole volume of the observed artery (r=0.852, p<0.0001) and also the percentage calcification volume (r=0.913, p<0.0001) calculated by the computed method, respectively. The percentage of atherosclerotic vascular diseases increased in the group of both high ASI (over 10%) and high ACI (over 20%). We used SCI as a reliable index when the progression and regression of atherosclerosis was considered. Among patients of hypercholesterolemia consisting of 15 with familial hypercholesterolemia (FH) and 6 non-FH patients, the change of SCI (d-SCI) was significantly correlated with the change of total cholesterol concentration (d-TC) after the treatment (r=0.466, p<0.05) and the change of the right Achilles' tendon thickening (d-ATT) was also correlated with d-TC (r=0.634, p<0.005). However, no correlation between d-SCI and d-ATT was observed. In conclusion, CT indices of atherosclerosis were useful as a noninvasive quantitative diagnostic method and we were able to use them to assess the progression and regression of atherosclerosis. (author)

  19. Diagnostic Value of Nineteen Different Imaging Methods for Patients with Breast Cancer: a Network Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Xiao-Hong Zhang

    2018-04-01

    Full Text Available Background/Aims: We performed a network meta-analysis (NMA to investigate and compare the diagnostic value of 19 different imaging methods used for breast cancer (BC. Methods: Cochrane Library, PubMed and EMBASE were searched to collect the relevant literature from the inception of the study until November 2016. A combination of direct and indirect comparisons was performed using an NMA to evaluate the combined odd ratios (OR and draw the surface under the cumulative ranking curves (SUCRA of the diagnostic value of different imaging methods for BC. Results: A total of 39 eligible diagnostic tests regarding 19 imaging methods (mammography [MG], breast-specific gamma imaging [BSGI], color Doppler sonography [CD], contrast-enhanced magnetic resonance imaging [CE-MRI], digital breast tomosynthesis [DBT], fluorodeoxyglucose positron-emission tomography/computed tomography [FDG PET/CT], fluorodeoxyglucose positron-emission tomography [FDG-PET], full field digital mammography [FFDM], handheld breast ultrasound [HHUS], magnetic resonance imaging [MRI], automated breast volume scanner [ABUS], magnetic resonance mammography [MRM], scintimammography [SMM], single photon emission computed tomography scintimammography [SPECT SMM], ultrasound elastography [UE], ultrasonography [US], mammography + ultrasonography [MG + US], mammography + scintimammography [MG + SMM], and ultrasound elastography + ultrasonography [UE + US] were included in the study. According to this network meta-analysis, in comparison to the MG method, the CE-MRI, MRI, MRM, MG + SMM and UE + US methods exhibited relatively higher sensitivity, and the specificity of the FDG PET/CT method was higher, while the BSGI and MRI methods exhibited higher accuracy. Conclusion: The results from this NMA indicate that the diagnostic value of the BSGI, MG + SMM, MRI and CE-MRI methods for BC were relatively higher in terms of sensitivity, specificity and accuracy.

  20. Changes in hospitalization rate and mortality after acute myocardial infarction in Denmark after diagnostic criteria and methods changed

    DEFF Research Database (Denmark)

    Abildstrøm, Steen Zabell; Rasmussen, Søren; Madsen, Mette

    2004-01-01

    AIMS: To analyse the effect of the change in diagnostic criteria for acute myocardial infarction (AMI) and the use of troponin as a diagnostic marker on the hospitalization rate and mortality of hospitalized AMI patients from 1994 to 2001. METHODS AND RESULTS: Patients (> or =30 years) admitted...... for their first AMI were identified using the National Patient Registry in Denmark. We registered when each hospital introduced troponin as a diagnostic marker. The reported hospitalization rate decreased until 1998 and then increased substantially from 1999 to 2001 from 3472 to 4163 per million inhabitants (19.......9%) for men and from 1648 to 2020 per million inhabitants (22.6%) for women. Troponin use was associated with a significant 14% increase in hospitalization rate in this period [rate ratio 1.14, 95% confidence interval (CI) 1.11-1.18]. The effect of troponin was greatest among patients 70 years and older (rate...

  1. Application of Synchrotron Radiation-based Methods for Environmental Biogeochemistry: Introduction to the Special Section

    Energy Technology Data Exchange (ETDEWEB)

    Hettiarachchi, Ganga M.; Donner, Erica; Doelsch, Emmanuel

    2017-01-01

    To understand the biogeochemistry of nutrients and contaminants in environmental media, their speciation and behavior under different conditions and at multiple scales must be determined. Synchrotron radiation-based X-ray techniques allow scientists to elucidate the underlying mechanisms responsible for nutrient and contaminant mobility, bioavailability, and behavior. The continuous improvement of synchrotron light sources and X-ray beamlines around the world has led to a profound transformation in the field of environmental biogeochemistry and, subsequently, to significant scientific breakthroughs. Following this introductory paper, this special collection includes 10 papers that either present targeted reviews of recent advancements in spectroscopic methods that are applicable to environmental biogeochemistry or describe original research studies conducted on complex environmental samples that have been significantly enhanced by incorporating synchrotron radiation-based X-ray technique(s). We believe that the current focus on improving the speciation of ultra-dilute elements in environmental media through the ongoing optimization of synchrotron technologies (e.g., brighter light sources, improved monochromators, more efficient detectors) will help to significantly push back the frontiers of environmental biogeochemistry research. As many of the relevant techniques produce extremely large datasets, we also identify ongoing improvements in data processing and analysis (e.g., software improvements and harmonization of analytical methods) as a significant requirement for environmental biogeochemists to maximize the information that can be gained using these powerful tools.

  2. Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies

    International Nuclear Information System (INIS)

    Almen, A.J.

    1995-09-01

    A method for estimating mean absorbed dose to different organs and tissues was developed for paediatric patients undergoing X-ray investigations. The absorbed dose distribution in water was measured for the specific X-ray beam used. Clinical images were studied to determine X-ray beam positions and field sizes. Size and position of organs in the patient were estimated using ORNL phantoms and complementary clinical information. Conversion factors between the mean absorbed dose to various organs and entrance surface dose for five different body sizes were calculated. Direct measurements on patients estimating entrance surface dose and energy imparted for common X-ray investigations were performed. The examination technique for a number of paediatric X-ray investigations used in 19 Swedish hospitals was studied. For a simulated pelvis investigation of a 1-year old child the entrance surface dose was measured and image quality was estimated using a contrast-detail phantom. Mean absorbed doses to organs and tissues in urography, lung, pelvis, thoracic spine, lumbar spine and scoliosis investigations was calculated. Calculations of effective dose were supplemented with risk calculations for special organs e g the female breast. The work shows that the examination technique in paediatric radiology is not yet optimised, and that the non-optimised procedures contribute to a considerable variation in radiation dose. In order to optimise paediatric radiology there is a need for more standardised methods in patient dosimetry. It is especially important to relate measured quantities to the size of the patient, using e g the patient weight and length. 91 refs, 17 figs, 8 tabs

  3. Radiation dose to children in diagnostic radiology. Measurements and methods for clinical optimisation studies

    Energy Technology Data Exchange (ETDEWEB)

    Almen, A J

    1995-09-01

    A method for estimating mean absorbed dose to different organs and tissues was developed for paediatric patients undergoing X-ray investigations. The absorbed dose distribution in water was measured for the specific X-ray beam used. Clinical images were studied to determine X-ray beam positions and field sizes. Size and position of organs in the patient were estimated using ORNL phantoms and complementary clinical information. Conversion factors between the mean absorbed dose to various organs and entrance surface dose for five different body sizes were calculated. Direct measurements on patients estimating entrance surface dose and energy imparted for common X-ray investigations were performed. The examination technique for a number of paediatric X-ray investigations used in 19 Swedish hospitals was studied. For a simulated pelvis investigation of a 1-year old child the entrance surface dose was measured and image quality was estimated using a contrast-detail phantom. Mean absorbed doses to organs and tissues in urography, lung, pelvis, thoracic spine, lumbar spine and scoliosis investigations was calculated. Calculations of effective dose were supplemented with risk calculations for special organs e g the female breast. The work shows that the examination technique in paediatric radiology is not yet optimised, and that the non-optimised procedures contribute to a considerable variation in radiation dose. In order to optimise paediatric radiology there is a need for more standardised methods in patient dosimetry. It is especially important to relate measured quantities to the size of the patient, using e g the patient weight and length. 91 refs, 17 figs, 8 tabs.

  4. Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods

    Directory of Open Access Journals (Sweden)

    Kênia de Fátima Carrijo

    2014-06-01

    Full Text Available ABSTRACT. Carrijo K.F., Nascimento E.R., Pereira V.L.A., Morés N., Klein, C.S., Domingues L.M. & Tortelly R. [Diagnosis of porcine enzootic pneumonia by post mortem sanitary inspection: comparison with other diagnostic methods.] Diagnóstico da pneumonia enzoótica suína pela inspeção sanitária post mortem: comparação com outros métodos de diagnóstico. Revista Brasileira de Veterinária Brasileira 36(2:188-194, 2014. Faculdade de Medicina Veterinária, Universidade Federal de Uberlândia, Av. Pará, 1720, Bloco 2T, Jardim Umuarama, Uberlândia, MG 38400-902, Brasil. E-mail: keniacarrijo@ famev.ufu.br To compare the concordance of the diagnosis of porcine enzootic pneumonia (PEP by post-mortem Sanitary Inspection with other methods (histophatology and immunohistochemistry - IHC, were used lung tissue samples from 100 pigs slaughtered under sanitary inspection, and 50 of these had macroscopic lesions suggestive of PEP and 50 had no such lesions. These were fixed in 10% buffered formalin and processed by routine procedures for paraffin embedding and IHC technique for Mycoplasma hyopneumoniae using a monoespecific polyclonal antibody. The study demonstrating that there is concordance between the diagnosis of Sanitary Inspection with histophatology, between the diagnosis of Sanitary Inspection with IHC and histophatology with IHC. It can be conclude that when the lung has gross lesions of PEP, the probability the result is positive to M. hyopneumoniae by IHC and the presence of microscopic lesions increases. Thus, the microscopic diagnosis for PEP is feasible because it is associated to the other, so that the diagnosis given by the officials of Sanitary Inspection in slaughterhouses is not wrong; the macroscopic diagnosis is therefore a valid method for the diagnosis of PEP, it being understood this is not to say that the detection of M. hyopneumoniae.

  5. Selected methods of electron-and ion-diagnostics in tokamak scrape-off-layer

    Directory of Open Access Journals (Sweden)

    Sadowski Marek J.

    2015-06-01

    Full Text Available This invited paper considers reasons why exact measurements of fast electron and ion losses in tokamaks, and particularly i n a scrape-off-layer and near a divertor region, are necessary in order to master nuclear fusion energy production. Attention is also paid to direct measurements of escaping fusion products from D-D and D-T reactions, and in particular of fast alphas which might be used for plasma heating. The second part describes the generation of so-called runaway and ripple-born electrons which might induce high energy losses and cause severe damages of internal walls in fusion facilities. Advantages and disadvantages of different diagnostic methods applied for studies of such fast electrons are discussed. Particular attention is paid to development of a direct measuring technique based on the Cherenkov effect which might be induced by fast electrons in appropriate radiators. There are presented various versions of Cherenkov-type probes which have been developed by the NCBJ team and applied in different tokamak experiments. The third part is devoted to direct measurements of fast ions (including those produced by the nuclear fusion reactions which can escape from a high-temperature plasma region. Investigation of fast fusion-produced protons from tokamak discharges is reported. New ion probes, which were developed by the NCBJ team, are also presented. For the first time there is given a detailed description of an ion pinhole camera, which enables irradiation of several nuclear track detectors during a single tokamak discharge, and a miniature Thomson-type mass-spectrometer, which can be used for ion measurements at plasma borders.

  6. Impulse oscillometry system as an alternative diagnostic method for chronic obstructive pulmonary disease.

    Science.gov (United States)

    Wei, Xia; Shi, Zhihong; Cui, Yajuan; Mi, Jiuyun; Ma, Zhengquan; Ren, Jingting; Li, Jie; Xu, Shudi; Guo, Youmin

    2017-11-01

    We aimed to compare impulse oscillation system (IOS) and traditional pulmonary function tests (PFTs) for the assessment of the severity of chronic obstructive pulmonary disease (COPD), and to assess the use of IOS parameters to identify patients who were forced expiratory volume in 1 second (FEV1)%pred IOS. Diagnostic performance of IOS parameters to determine indication for patients of FEV1%pred operating characteristics (ROC) curve analysis.Out of 215 patients, 18, 83, 78, and 36 patients were classified as grade 1, 2, 3, and 4, respectively, according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) severity grading. On Spearman correlation analysis, FEV1%pred, MMEF 75%-25%, and residual volume/total lung capacity (RV/TLC) correlated with total respiratory impedance (Z5)%pred, resistance at 5 Hz (R5)-resistance at 20 Hz (R20), R5-R20% R5, R5, R5%pred, frequency response (Fres), reactance area (Ax), and reactance at 5 Hz (X5). On ROC curve analysis, the area under the curve (AUC) of X5 absolute value, Fres, Ax, Z5%pred, R5-R20, and R5-R20% R5 were 0.748, 0.755, 0.760, 0.705, 0.715, and 0.735, respectively, for COPD patients who required inhalational glucocorticoid therapy.IOS parameters showed a good correlation with traditional pulmonary function parameters; reactance parameters showed a stronger correlation than that of the resistance parameters. IOS can be used as an alternative method for pulmonary function assessment in patients with COPD with FEV1%pred < 50% who need inhalational glucocorticoid therapy. ChiCTR-OCH-14004904.

  7. Methods for the field evaluation of quantitative G6PD diagnostics: a review.

    Science.gov (United States)

    Ley, Benedikt; Bancone, Germana; von Seidlein, Lorenz; Thriemer, Kamala; Richards, Jack S; Domingo, Gonzalo J; Price, Ric N

    2017-09-11

    Individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk of severe haemolysis following the administration of 8-aminoquinoline compounds. Primaquine is the only widely available 8-aminoquinoline for the radical cure of Plasmodium vivax. Tafenoquine is under development with the potential to simplify treatment regimens, but point-of-care (PoC) tests will be needed to provide quantitative measurement of G6PD activity prior to its administration. There is currently a lack of appropriate G6PD PoC tests, but a number of new tests are in development and are likely to enter the market in the coming years. As these are implemented, they will need to be validated in field studies. This article outlines the technical details for the field evaluation of novel quantitative G6PD diagnostics such as sample handling, reference testing and statistical analysis. Field evaluation is based on the comparison of paired samples, including one sample tested by the new assay at point of care and one sample tested by the gold-standard reference method, UV spectrophotometry in an established laboratory. Samples can be collected as capillary or venous blood; the existing literature suggests that potential differences in capillary or venous blood are unlikely to affect results substantially. The collection and storage of samples is critical to ensure preservation of enzyme activity, it is recommended that samples are stored at 4 °C and testing occurs within 4 days of collection. Test results can be visually presented as scatter plot, Bland-Altman plot, and a histogram of the G6PD activity distribution of the study population. Calculating the adjusted male median allows categorizing results according to G6PD activity to calculate standard performance indicators and to perform receiver operating characteristic (ROC) analysis.

  8. Textbook on X-ray diagnostics. Substantiated by Marianne Zimmer-Brossy. 6. new rev. ed.

    International Nuclear Information System (INIS)

    Becht, Stefanie; Bittner, Roland C.; Ohmstede, Anke; Pfeiffer, Andreas; Rossdeutscher, Reinhard

    2008-01-01

    The standard textbook on x-ray diagnostics has been revised by the MTRA team and radiologists: The book covers the following topics: General information: the profession of a radiologist, the x-ray department, radiation protection, quality assurance, basic physics, x-ray imaging, analog and digital image processing, archives, image interpretation. Skeleton diagnostics; Inner organs (thorax organs, neck, abdomen, gastrointestinal tract, colon, gall bladder and biliary tract): Special x-ray diagnostic methods: x-ray diagnostic of the female and male chest, x-ray diagnostics of bone joints (arthrography, and contrast media), x-ray diagnostics of the urinary-genital system, x-ray diagnostics of cavities and syrinx, x-ray diagnostics of arteries (arteriography, angiography), percutaneous transluminal angioplasty, x-ray diagnostics of veins (phlebography), x-ray diagnostics of lymphatic vessels and lymph nodes, x-ray diagnostics of spinal cord (myelography); Specific imaging methods: computerized tomography [de

  9. Diagnostics of Polymer Composite Materials and Analysis of Their Production Technology by Using the Method of Acoustic Emission

    Science.gov (United States)

    Bashkov, O. V.; Protsenko, A. E.; Bryanskii, A. A.; Romashko, R. V.

    2017-09-01

    The strength properties of glass-fiber-reinforced plastics produced by vacuum and vacuum autoclave molding techniques are studied. Based on acoustic emission data, a method of diagnostic and prediction of the bearing capacity of polymer composite materials by using data from three-point bending tests is developed. The method is based on evaluating changes in the exponent of a power function relating the total acoustic emission to the test stress.

  10. Combating stress risks with the job stress self diagnostic method: paper XV World Congress of Sociology 2002

    OpenAIRE

    Oeij, P.R.A.

    2002-01-01

    In this paper of the World Congress of Sociology 2002 of ISA (International Sociological Association), the content and uses of the Job Stress Self Diagnostic Method (JSSDM) are described. The JSSDM aim is (a) to diagnose work processes to determine the presence of conditions for control problems and stress risks, and (b) to develop solutions to combat stress risks on organisational level. The method is based on three theories of job and organisation design and on the insight to combine viewpo...

  11. Development and Validation of a Method for Determining Tridimensional Angular Displacements with Special Applications to Ice Hockey Motions.

    Science.gov (United States)

    Gagnon, Micheline; And Others

    1983-01-01

    A method for determining the tridimensional angular displacement of skates during the two-legged stop in ice hockey was developed and validated. The angles were measured by geometry, using a cinecamera and specially equipped skates. The method provides a new tool for kinetic analyses of skating movements. (Authors/PP)

  12. Diagnostic accuracy of organ electrodermal diagnostics | Szopinski ...

    African Journals Online (AJOL)

    Objective. To estimate the diagnostic accuracy as well as the scope of utilisation of a new bio-electronic method of organ diagnostics. Design. Double-blind comparative study of the diagnostic results obtained by means of organ electrodermal diagnostics (OED) and clinical diagnoses, as a criterion standard. Setting.

  13. Distinguishing benign and malignant pelvic masses : The value of different diagnostic methods in everyday clinical practice

    NARCIS (Netherlands)

    Engelen, Mirjam J. A.; Bongaerts, Alphons H. H.; Sluiter, Wim J.; De Haan, Harm H.; Bogchelman, Dick H.; TenVergert, Els M.; Willemse, Pax H. B.; van der Zee, Ate G. J.

    Objective: To optimize referral to specialized gynaecologists for surgical treatment of ovarian cancer by improving preoperative discrimination between benign and malignant pelvic tumours. Study design: In a prospective multicentre study 143 patients with a pelvic mass were included. At several

  14. Changes in diagnostic methods of non-palpable breast lesions: analysis for 5 years

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Oh, Ki Keun; Kim, Mi Hye; You, Jai Kyung; Kwak, Jin Young; Park, Byeong Woo; Lee, Kyong Sik

    2002-01-01

    To describe the changes in diagnostic methods and reassess the role of core biopsy compared with needle localization biopsy (NLB) in the evaluation of non-palpable breast lesions. We retrospectively analyzed 930 non-palpable breast lesions which underwent either core biopsy or NLB between January 1996 and December 2000. NLB involved 511 lesions in 482 patients, and core 419 lesions in 365 patients. For a given lesion, NLB was guided by either mammography (n=213) or ultrasonography (US) (n=298), but only US was used to guide a core biopsy. Over the five-year period, we calculated the total number of biopsies per year relating to non-palpable breast lesions, also determining the mammographic findings in cases involving NLB and the percentage of malignancies seen at histopathology. The total number of biopsies increased with time: 1996: n=91, 1997: n=118, 1998: n=144, 1999: n=245, 2000: n=332. The implementation of core biopsy, however, led to a decrease in the proportion of NLB (1996: 97.8%, 1997:84.7%, 1998: 75.7%, 1999: 47.8%, 2000: 28.9%). Among nonpalpable lesions which underwent mammgraphy-guided MLB, 46.5% (20/43) were a mass or density in 1996, while in 2000 the proportion was 5.7% (2/35). During this period, however, the finding of calcification without a mass increased from 48.8% in 1996 to 94.3% in 2000. The proportion of cases in which NLB demonstrated malignancy increased from 13.5% in 1996 to 49% in 2000; where US-guided NLB was used, the increase was remarkable: from 15.2% in 1996 to 65.6% in 2000. In the evaluation of non-palpable breast lesions, the appropriate use of core biopsy can decrease the need for a more invasive method such as NLB. Furthermore, because most benign lesions diagnosed by core biopsy do not also undergo NLB, the use of the latter increases the yield of malignancies

  15. Accidental hypothermia in Poland – estimation of prevalence, diagnostic methods and treatment.

    Science.gov (United States)

    Kosiński, Sylweriusz; Darocha, Tomasz; Gałązkowski, Robert; Drwiła, Rafał

    2015-02-06

    The incidence of hypothermia is difficult to evaluate, and the data concerning the morbidity and mortality rates do not seem to fully represent the problem. The aim of the study was to estimate the actual prevalence of accidental hypothermia in Poland, as well as the methods of diagnosis and management procedures used in emergency rooms (ERs). A specially designed questionnaire, consisting of 14 questions, was mailed to all the 223 emergency rooms (ER) in Poland. The questions concerned the incidence, methods of diagnosis and risk factors, as well as the rewarming methods used and available measurement instruments. The analysis involved data from 42 ERs providing emergency healthcare for the population of 5,305,000. The prevalence of accidental hypothermia may have been 5.05 cases per 100.000 residents per year. Among the 268 cases listed 25% were diagnosed with codes T68, T69 or X31, and in 75% hypothermia was neither included nor assigned a code in the final diagnosis. The most frequent cause of hypothermia was exposure to cold air alongside ethanol abuse (68%). Peripheral temperature was measured in 57%, core temperature measurement was taken in 29% of the patients. Peripheral temperature was measured most often at the axilla, while core temperature measurement was predominantly taken rectally. Mild hypothermia was diagnosed in 75.5% of the patients, moderate (32-28°C) in 16.5%, while severe hypothermia (less than 28°C) in 8% of the cases. Cardiopulmonary resuscitation was carried out in 7.5% of the patients. The treatment involved mainly warmed intravenous fluids (83.5%) and active external rewarming measures (70%). In no case was extracorporeal rewarming put to use. The actual incidence of accidental hypothermia in Polish emergency departments may exceed up to four times the official data. Core temperature is taken only in one third of the patients, the treatment of hypothermic patients is rarely conducted in intensive care wards and extracorporeal rewarming

  16. The probability estimate of the defects of the asynchronous motors based on the complex method of diagnostics

    Science.gov (United States)

    Zhukovskiy, Yu L.; Korolev, N. A.; Babanova, I. S.; Boikov, A. V.

    2017-10-01

    This article is devoted to the development of a method for probability estimate of failure of an asynchronous motor as a part of electric drive with a frequency converter. The proposed method is based on a comprehensive method of diagnostics of vibration and electrical characteristics that take into account the quality of the supply network and the operating conditions. The developed diagnostic system allows to increase the accuracy and quality of diagnoses by determining the probability of failure-free operation of the electromechanical equipment, when the parameters deviate from the norm. This system uses an artificial neural networks (ANNs). The results of the system for estimator the technical condition are probability diagrams of the technical state and quantitative evaluation of the defects of the asynchronous motor and its components.

  17. Survey of the diagnostic retooling process in national TB reference laboratories, with special focus on rapid speciation tests endorsed by WHO in 2007.

    Directory of Open Access Journals (Sweden)

    Sanne C van Kampen

    Full Text Available BACKGROUND: Successful integration of new diagnostics in national tuberculosis (TB control programs, also called 'retooling', is highly dependent on operational aspects related to test availability, accessibility and affordability. This survey aimed to find out whether recommendations to use new diagnostics lead to successful retooling in high TB endemic countries, using immunochromatographic tests (ICTs for TB culture speciation as a case study. ICTs are recommended to accurately confirm the presence of bacteria of the Mycobacterium tuberculosis complex in liquid culture isolates. METHODS AND FINDINGS: Questionnaires were sent to national TB reference laboratories (NRLs in 42 high TB endemic countries to address their access to information on ICT implementation, logistics related to availability, accessibility and affordability of ICTs, and testing algorithms. Results from 16 responding countries indicated that half of the NRLs were aware of the contents of WHO guidance documents on liquid culture and ICT implementation, as well as their eligibility for a negotiated pricing agreement for ICT procurement. No major issues with availability and accessibility of ICTs were raised. When asked about testing algorithms, ICTs were not used as stand-alone or first test for TB culture identification as recommended by WHO. CONCLUSIONS: The low response rate was a limitation of this survey and together with NRLs managers' unawareness of global guidance, suggests a lack of effective communication between partners of the global laboratory network and NRLs. TB tests could become more affordable to high TB endemic countries, if the possibility to negotiate lower prices for commercial products is communicated to them more successfully. NRLs need additional guidance to identify where available technologies can be most usefully implemented and in what order, taking into account long-term laboratory strategies.

  18. Diagnostic methods for mastitis in cows are not appropriate for use in humans: commentary.

    Science.gov (United States)

    Kvist, Linda J

    2016-01-01

    Healthcare workers are now being targeted for marketing of diagnostic tools for mastitis that were developed for the dairy industry and which aim to provide information regarding choice of antibiotic treatment. Meanwhile, scientists are striving to understand how the human microbiome affects health and wellbeing and the importance of maintenance of bacterial balance in the human body. Breast milk supplies a multitude of bacteria to populate the baby's intestinal tract and kick-start the immune system. Researchers propose a paradigm shift in the understanding of bacterial content in breast milk and an alternative paradigm for the understanding of lactational mastitis: there is the beginning of evidence that many cases of lactational mastitis will resolve spontaneously. An international group of researchers is attempting to answer how dietary habits, birth mode, genetics and environmental factors may impact the bacterial content of breast milk. Until we have more comprehensive knowledge about the human milk microbiome, diagnostic aids for identification of women in need of antibiotic therapy for mastitis remain unreliable. Diagnostic aids could lead to the injudicious use of antibiotic therapy, which in turn may rob the infant of bacteria valuable for development of its immune system. The marketing of diagnostic aids for use in human medicine, that were originally developed for use in cows, is neither evidence-based nor good ethical practice.

  19. Statistical analysis and interpretation of prenatal diagnostic imaging studies, Part 2: descriptive and inferential statistical methods.

    Science.gov (United States)

    Tuuli, Methodius G; Odibo, Anthony O

    2011-08-01

    The objective of this article is to discuss the rationale for common statistical tests used for the analysis and interpretation of prenatal diagnostic imaging studies. Examples from the literature are used to illustrate descriptive and inferential statistics. The uses and limitations of linear and logistic regression analyses are discussed in detail.

  20. A Fault Diagnostic Method for Position Sensor of Switched Reluctance Wind Generator

    DEFF Research Database (Denmark)

    Wang, Chao; Liu, Xiao; Liu, Hui

    2016-01-01

    Fast and accurate fault diagnosis of the position sensor is of great significance to ensure the reliability as well as sensor fault tolerant operation of the Switched Reluctance Wind Generator (SRWG). This paper presents a fault diagnostic scheme for a SRWG based on the residual between the estim...

  1. Experimental Design and Methods for Development of Diagnostic Assays for Schistosomiasis Using Monoclonal Antibodies.

    Science.gov (United States)

    1983-08-25

    solium, Echinococcus granulosus , Entamoeba histolytica, or Wucher erTra-bancr--ofti. The S. mansoni glycoproteins that were immunoprecipitated by sera...Sera from patients or experimental animals infected with Schistosoma, Fasciola hepatica, Trichinella spiralis, Taenia solium, Echinococcus ... granulosus , or Paragonimus westermani cross-react in diag-nostic assays with antigens derived from schistosomes, whether as whole organisms (1-4), crude

  2. The methods for diagnostic of the technical condition of vehicles employing high precise satellite data

    Directory of Open Access Journals (Sweden)

    Anatoliy KULIK

    2014-03-01

    Full Text Available The paper presents a methodology for diagnostic of the technical condition of vehicle. The high accuracy of the actual trajectory of the transport aggregate (TA is provided by the use of local differential mode of global navigation satellite system (GNSS. Comparing the real and rational trajectories will determine the kinematic and dynamic characteristics of the car.

  3. Novel Readout Method for Molecular Diagnostic Assays Based on Optical Measurements of Magnetic Nanobead Dynamics

    DEFF Research Database (Denmark)

    Donolato, Marco; Antunes, Paula Soares Martins; Bejhed, Rebecca S.

    2015-01-01

    behavior. We prove that the optical transmission spectra are highly sensitive to the formation of permanent MNB clusters and, thereby to the target analyte concentration. As a specific clinically relevant diagnostic case, we detect DNA coils formed via padlock probe recognition and isothermal rolling...

  4. A multi-center comparison of diagnostic methods for the biochemical evaluation of suspected mitochondrial disorders

    NARCIS (Netherlands)

    Rodenburg, R.J.T.; Schoonderwoerd, G.C.; Tiranti, V.; Taylor, R.W.; Rotig, A.; Valente, L.; Invernizzi, F.; Chretien, D.; He, L.; Backx, G.P.; Janssen, K.J.; Chinnery, P.F.; Smeets, H.J.M.; Coo, I.F. de; Heuvel, L.P. van den

    2013-01-01

    A multicenter comparison of mitochondrial respiratory chain and complex V enzyme activity tests was performed. The average reproducibility of the enzyme assays is 16% in human muscle samples. In a blinded diagnostic accuracy test in patient fibroblasts and SURF1 knock-out mouse muscle, each lab made

  5. The diagnostic performance of imaging methods in ARVC using the 2010 Task Force criteria

    DEFF Research Database (Denmark)

    Borgquist, Rasmus; Haugaa, Kristina H; Gilljam, Thomas

    2014-01-01

    , fractional area shortening 31 ± 9 vs. 39 ± 9% (P performance was low; sensitivity 50% and specificity 70%, positive predictive value 80% and negative predictive value 37...... evaluation of subtle structural changes in the right ventricle may be unreliable, and the diagnostic performance of CMR compared with echocardiography should be reflected in the guidelines....

  6. Development of a test bed plasma and diagnostic methods for detailed K-shell spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Hall, I.M.; Chambers, D.M.; Courtois, C.; Förster, E.; Gregory, C.D.; Howe, J.; Renner, Oldřich; Uschmann, I.; Woolsey, N.C.

    2006-01-01

    Roč. 133, - (2006), s. 1009-1011 ISSN 1155-4339 R&D Projects: GA MŠk LC528 Institutional research plan: CEZ:AV0Z10100523 Keywords : laser-produced plasmas * x-ray and optical emission * plasma modelling * plasma diagnostics Subject RIV: BH - Optics, Masers, Lasers Impact factor: 0.315, year: 2006

  7. Initial radioiodine remnant ablation success rates compared by diagnostic scan methods: I123 versus I131

    International Nuclear Information System (INIS)

    Choi, W.; Choi, E.; Yoo, I.; Kim, S.; Han, E.; Lee, S.; Lee, W.

    2015-01-01

    Full text of publication follows. Objective: to see if diagnostic whole body scan (DxWBS) performed with I-131 prior diminishes the success rate of initial radioiodine remnant ablation (RRA) compared to I-123 DxWBS in differentiated thyroid cancer patients. Material and methods: consecutive thyroid cancer patients who received total thyroidectomy for differentiated thyroid cancer and then high dose RRA (either 100 mCi or 150 mCi) within 6 months were included. DxWBSs were performed with I-123 or with I-131. Prior to the DxWBSs, all patients followed strict low iodine diet for 2 weeks and withdrew hormone to stimulate TSH above 30 mIU/l. Patients with extra-thyroidal extension of tumor, lymph node metastasis, or distant metastasis were excluded. The initial RRA was defined as successful if the next DxWBS done 6 months to 1 year later was negative and stimulated thyroglobulin level was below 2 ng/ml. Results: of 71 patients who had I-123 DxWBSs, 31 patients went on to receive RRA with 100 mCi and 40 patients received 150 mCi. Of 73 patients who had I-131 DxWBSs, 66 received 100 mCi and 7 patients received 150 mCi. The overall success rate was 79% for patients who had I-123 DxWBS prior to RRA (68% for 100 mCi and 86% for 150 mCi), and 68% for patient who had I-131 DxWBSs (68% for 100 mCi and 71% for 150 mCi). Conclusion: for patients who received 100 mCi, the RRA success rate was the same for I-123 DxWBS and I-131 DxWBS. For patients treated with 150 mCi, the success rate may be lower in patients who receive RRA following DxWBS with I-131 compared to DxWBS with I-123. (authors)

  8. The effectiveness of diagnostic imaging methods for the assessment of soft tissue and articular disorders of the shoulder and elbow

    Energy Technology Data Exchange (ETDEWEB)

    Shahabpour, M. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)], E-mail: Maryam@shahabpour.uzbrussel; Kichouh, M.; Laridon, E. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium); Gielen, J.L. [Department of Radiology, Universitair Ziekenhuis Antwerpen, Universiteit Antwerpen, Wilrijkstraat 10, 2650 Edegem (Belgium); De Mey, J. [Department of Radiology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussels (Belgium)

    2008-02-15

    There are no clear guidelines for diagnostic imaging of articular and soft tissue pathologies of the shoulder and elbow. Several methods are used, including magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and ultrasound (US). Their cost-effectiveness is still unclear. We performed a meta-analysis of the relevant literature and discussed the role of MR imaging of the shoulder and elbow compared with other diagnostic imaging modalities. For the shoulder impingement syndrome and rotator cuff tears, MRI and US have a comparable accuracy for detection of full-thickness rotator cuff tears. MRA and US might be more accurate for the detection of partial-thickness tears than MRI. Given the large difference in cost of MR and US, ultrasound may be the most cost-effective diagnostic method for identification of full-thickness tears in a specialist hospital setting (Evidence level 3). Both MRA and CT arthrography (CTA) are effective methods for the detection of labrum tears. More recently, multidetector CTA has offered the advantages of thinner slices than with MRA in a shorter examination time. Still, MRA has the advantage towards CTA to directly visualize the affected structures with a better evaluation of extent and location and to detect associated capsuloligamentous injuries. For the elbow pathologies, plain MRI or MRA have the advantage towards CTA to detect occult bone injuries. CTA is better for the assessment of the thin cartilage of the elbow. Both US and MRI are reliable methods to detect chronic epicondylitis; US is more available and far more cost-effective (Evidence level 2). MRA can differentiate complete from partial tears of the medial collateral ligament. US or MRI can detect partial and complete biceps tendon tears and/or bursitis. MRI can provide important diagnostic information in lesions of the ulnar, radial, or median nerve.

  9. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for clinical and research applications: recommendations of the international RDC/TMD consortium network and orofacial pain special interest group

    NARCIS (Netherlands)

    Schiffman, E.; Ohrbach, R.; Truelove, E.; Look, J.; Anderson, G.; Goulet, J.P.; List, T.; Svensson, P.; Gonzalez, Y.; Lobbezoo, F.; Michelotti, A.; Brooks, S.L.; Ceusters, W.; Drangsholt, M.; Ettlin, D.; Gaul, C.; Goldberg, L.J.; Haythornthwaite, J.A.; Hollender, L.; Jensen, R.; John, M.T.; De Laat, A.; de Leeuw, R.; Maixner, W.; van der Meulen, M.; Murray, G.M.; Nixdorf, D.R.; Palla, S.; Petersson, A.; Pionchon, P.; Smith, B.; Visscher, C.M.; Zakrzewska, J.; Dworkin, S.F.

    2014-01-01

    AIMS: The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥

  10. The simple analytical method for scattered radiation calculation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In realization of radiation protection measures for medical staff present during diagnostic procedures, the necessary condition is knowledge of the space - energy distributions of the scattered radiation from the patient. In this paper, the simple calculation procedure for the scattered radiation field of the actual diagnostic energies is presented. Starting from the single Compton scattering model and using the justified transformations the final equations in elementary form are derived. For numerical calculations the computer code ANGIO was created. The calculated results were confirmed by detailed dosimetric measurements of the scattered field around patient (the water phantom) in SSDL in the Institute of nuclear sciences `Vinca`, Belgrade. These results are good base for assessment of irradiation. The main irradiation source for the physician and the other members of the medical team is the back scattered radiation from patient - albedo. (author). 3 figs., 3 refs.

  11. Raman spectroscopy of saliva as a perspective method for periodontitis diagnostics Raman spectroscopy of saliva

    Science.gov (United States)

    Gonchukov, S.; Sukhinina, A.; Bakhmutov, D.; Minaeva, S.

    2012-01-01

    In view of its potential for biological tissues analyses at a molecular level, Raman spectroscopy in optical range has been the object of biomedical research for the last years. The main aim of this work is the development of Raman spectroscopy for organic content identifying and determination of biomarkers of saliva at a molecular level for periodontitis diagnostics. Four spectral regions were determined: 1155 and 1525 cm-1, 1033 and 1611 cm-1, which can be used as biomarkers of this widespread disease.

  12. Renal candidiasis in newborn: the ultrasonography as diagnostic and therapeutic method

    International Nuclear Information System (INIS)

    Lopez Pino, M.A.; Serrano Hernandez, C.; Alba Romero, C.; Aransay Bramtot, A.; Paul Diaz, L.

    1995-01-01

    We present a case of systemic candidiasis in a low-weight newborn. Renal involvement presented as unilateral hydronephrosis secondary to the fungal construction. Ultrasound served not only as a diagnostic tool, but as a guide for the performance of performance of percutaneous nephrostomy which was included in the therapeutic approach to decompress the excretory pathway and allow local installation of anti fungal agents. (Author) 16 refs

  13. Prenatal radiation exposures at diagnostic procedures: methods to identify exposed pregnant patients

    International Nuclear Information System (INIS)

    Pettersson, H.; Sandborg, M.; Nilsson, J.; Olsson, S.

    2002-01-01

    Knowledge about frequency and doses to embryo/foetus from diagnostic radiology is of great importance both in the sense of estimating the radiation risks but also for optimizing the diagnostic procedures and making decisions regarding alternative procedures. In addition, the pregnant patient has the right to know the magnitude and type of radiation risks expected as a result of foetus exposure. From a risk perspective epidemiological data have shown that the embryo/foetus together with children experience higher radiation sensitivity in terms of induced leukemia and cancer compared to an adult population. Recent estimates give cancer excess lifetime mortality risks for whole body exposures of children and foetus (0-15 y age) of 0.06% (ICRP84, 2000) up to 0.14% per 10 mSv (BEIR-V 1990). In addition to the risk of cancer induction effects of cell killing, e.g. CNS abnormalities, cataracts, malformations, growth retardation, may occur. However, these effects are believed to have a threshold, about 100-200 mGy (ICRP84, 2000), and such foetus doses are rarely reached in diagnostic radiology procedures. There are 2 principal situations where foetus exposures may occur in diagnostic radiology; 1. The pregnancy of the patient is known at the time of examination, but due to the medical indications the examination can not be postponed or put forward in time, and there are no suitable alternative non-radiological procedures. 2. The pregnancy of the patient is not known at the time of examination, either due to the fact that the patient is unaware of her pregnancy or the medical personnel failed to obtain this information. The former situation may occur during the first few weeks from conception, whereas the latter situation may cover a greater gestation period

  14. Diagnostic criteria in MR neurography

    International Nuclear Information System (INIS)

    Baeumer, P.

    2017-01-01

    Peripheral neuropathies are frequent and can mostly be correctly diagnosed by clinical examination and electrophysiology; however, diagnostically difficult cases are sometimes encountered especially with respect to precise localization of nerve lesions. Imaging of the peripheral nervous system has been shown to provide additional useful diagnostic information. In addition to the more widely available nerve sonography, magnetic resonance neurography (MRN) is the method of choice in diagnostically complex cases. The most important pulse sequence is a T2-weighted fat-saturated pulse sequence with high in-plane resolution and detects increased T2-weighted signals of nerve fascicles as a highly sensitive sign for nerve lesions. Further established diagnostic criteria are nerve caliber and, less commonly used, contrast agent uptake. The spatial pattern of nerve lesions aids in the diagnostic classification of neuropathies. Functional imaging techniques, such as diffusion tensor imaging (DTI) and nerve perfusion are currently under examination with respect to the clinical potential. If all other diagnostic methods, including clinical examination, electrophysiology and nerve sonography do not arrive at an unambiguous diagnosis of a peripheral neuropathy, MRN should be used. The special value of MRN is demonstrated particularly in complex nerve lesions, such as traumatic plexopathies and in partial fascicular neuropathies and many other indications. (orig.) [de

  15. Minimal methylation classifier (MIMIC): A novel method for derivation and rapid diagnostic detection of disease-associated DNA methylation signatures.

    Science.gov (United States)

    Schwalbe, E C; Hicks, D; Rafiee, G; Bashton, M; Gohlke, H; Enshaei, A; Potluri, S; Matthiesen, J; Mather, M; Taleongpong, P; Chaston, R; Silmon, A; Curtis, A; Lindsey, J C; Crosier, S; Smith, A J; Goschzik, T; Doz, F; Rutkowski, S; Lannering, B; Pietsch, T; Bailey, S; Williamson, D; Clifford, S C

    2017-10-18

    Rapid and reliable detection of disease-associated DNA methylation patterns has major potential to advance molecular diagnostics and underpin research investigations. We describe the development and validation of minimal methylation classifier (MIMIC), combining CpG signature design from genome-wide datasets, multiplex-PCR and detection by single-base extension and MALDI-TOF mass spectrometry, in a novel method to assess multi-locus DNA methylation profiles within routine clinically-applicable assays. We illustrate the application of MIMIC to successfully identify the methylation-dependent diagnostic molecular subgroups of medulloblastoma (the most common malignant childhood brain tumour), using scant/low-quality samples remaining from the most recently completed pan-European medulloblastoma clinical trial, refractory to analysis by conventional genome-wide DNA methylation analysis. Using this approach, we identify critical DNA methylation patterns from previously inaccessible cohorts, and reveal novel survival differences between the medulloblastoma disease subgroups with significant potential for clinical exploitation.

  16. A method for assay of special nuclear material in high level liquid waste streams

    International Nuclear Information System (INIS)

    Venkata Subramani, C.R.; Swaminathan, K.; Asuvathraman, R.; Kutty, K.V.G.

    2003-01-01

    The assay of special nuclear material in the high level liquid waste streams assumes importance as this is the first stage in the extraction cycle and considerable losses of plutonium could occur here. This stream contains all the fission products as also the minor actinides and hence normal nuclear techniques cannot be used without prior separation of the special nuclear material. This paper presents the preliminary results carried out using wavelength dispersive x-ray fluorescence as part of the developmental efforts to assay SNM in these streams by instrumental techniques. (author)

  17. Lectin-induced agglutination method of urinary exosomes isolation followed by mi-RNA analysis: Application for prostate cancer diagnostic.

    Science.gov (United States)

    Samsonov, Roman; Shtam, Tatiana; Burdakov, Vladimir; Glotov, Andrey; Tsyrlina, Evgenia; Berstein, Lev; Nosov, Alexander; Evtushenko, Vladimir; Filatov, Michael; Malek, Anastasia

    2016-01-01

    Prostate cancer is the most common cancer in men. Prostate-specific antigen has, however, insufficient diagnostic specificity. Novel complementary diagnostic approaches are greatly needed. MiRNAs are small regulatory RNAs which play an important role in tumorogenesis and are being investigated as a cancer biomarker. In addition to their intracellular regulatory functions, miRNAs are secreted into the extracellular space and can be found in various body fluids, including urine. The stability of extracellular miRNAs is defined by association with proteins, lipoprotein particles, and membrane vesicles. Among the known forms of miRNA packaging, tumour-derived exosome-enclosed miRNAs is thought to reflect the vital activity of cancer cells. The assessment of the exosomal fraction of urinary miRNA may present a new and highly specific method for prostate cancer diagnostics; however, this is challenged by the absence of reliable and inexpensive methods for isolation of exosomes. Prostate cancer (PC) cell lines and urine samples collected from 35 PC patients and 35 healthy donors were used in the study. Lectins, phytohemagglutinin, and concanavalin A were used to induce agglutination of exosomes. The efficiency of isolation process was evaluated by AFM and DLS assays. The protein content of isolated exosomes was analysed by western blotting. Exosomal RNA was assayed by automated electrophoresis and expression level of selected miRNAs was evaluated by RT-qPCR. The diagnostic potency of the urinary exosomal miRNA assessment was estimated by the ROC method. The formation of multi-vesicular agglutinates in urine can be induced by incubation with lectin at a final concentration of 2 mg/ml. These agglutinates contain urinary exosomes and may be pelleted by centrifugation with a relatively low G-force. The analysis of PC-related miRNA in urinary exosomes revealed significant up-regulation of miR-574-3p, miR-141-5p, and miR-21-5p associated with PC. Lectin-induced aggregation is a

  18. Diagnostic validation of three test methods for detection of cyprinid herpesvirus 3 (CyHV-3).

    Science.gov (United States)

    Clouthier, Sharon C; McClure, Carol; Schroeder, Tamara; Desai, Megan; Hawley, Laura; Khatkar, Sunita; Lindsay, Melissa; Lowe, Geoff; Richard, Jon; Anderson, Eric D

    2017-03-06

    Cyprinid herpesvirus 3 (CyHV-3) is the aetiological agent of koi herpesvirus disease in koi and common carp. The disease is notifiable to the World Organisation for Animal Health. Three tests-quantitative polymerase chain reaction (qPCR), conventional PCR (cPCR) and virus isolation by cell culture (VI)-were validated to assess their fitness as diagnostic tools for detection of CyHV-3. Test performance metrics of diagnostic accuracy were sensitivity (DSe) and specificity (DSp). Repeatability and reproducibility were measured to assess diagnostic precision. Estimates of test accuracy, in the absence of a gold standard reference test, were generated using latent class models. Test samples originated from wild common carp naturally exposed to CyHV-3 or domesticated koi either virus free or experimentally infected with the virus. Three laboratories in Canada participated in the precision study. Moderate to high repeatability (81 to 99%) and reproducibility (72 to 97%) were observed for the qPCR and cPCR tests. The lack of agreement observed between some of the PCR test pair results was attributed to cross-contamination of samples with CyHV-3 nucleic acid. Accuracy estimates for the PCR tests were 99% for DSe and 93% for DSp. Poor precision was observed for the VI test (4 to 95%). Accuracy estimates for VI/qPCR were 90% for DSe and 88% for DSp. Collectively, the results show that the CyHV-3 qPCR test is a suitable tool for surveillance, presumptive diagnosis and certification of individuals or populations as CyHV-3 free.

  19. Clustering methods and visualization algorithms to aid nuclear reactor operative diagnostics

    International Nuclear Information System (INIS)

    Pepelyshev, Yu.N.; Dzwinel, W.

    1990-01-01

    The software system developed plays the role of the aid to an operator for nuclear reactor diagnostics. The noise analysis of the reactor parameters such as power, temperature and coolant flow rate constitutes the basis of the system. Combination of data acquisition, data preprocessing, clustering and cluster visualization algorithms with heuristic techniques of results analysis, determine the way of its implementation. Two regimes are available. The first one - extended - is recommended for a long term investigations and the second - suppressed for the aid to the reactor operation monitoring. The system has been tested and developed at the JINR IBR-2 pulsed reactor. 13 refs.; 4 figs.; 2 tabs

  20. The application of improved, structured and interactive group learning methods in diagnostic radiology

    International Nuclear Information System (INIS)

    Ivarsson, Jonas; Rystedt, Hans; Baath, Magnus; Asplund, Sara; Allansdotter Johnsson, Aase

    2016-01-01

    This study provides an example on how it is possible to design environments in a diagnostic radiology department that could meet learning demands implied by the introduction of new imaging technologies. The innovative aspect of the design does not result from the implementation of any specific tool for learning. Instead, advancement is achieved by a novel set-up of existing technologies and an interactive format that allows for focussed discussions between learners with different levels of expertise. Consequently, the study points to what is seen as the under-explored possibilities of tailoring basic and specialist training that meet the new demands given by leading-edge technologies. (authors)

  1. Prenatal Radiation exposures at diagnostic procedures: methods to identify exposed pregnant patients

    International Nuclear Information System (INIS)

    Pettersson, H.; Sandborg, M.; Nilsson, J.; Olsson, S.; Hellman, S.; Helmrot, E.; Persliden, J.; Cederlund, T.

    2003-01-01

    Knowledge about frequency and doses to embryo/foetus from diagnostic radiology is of great importance both in the sense of estimating the radiation risks but also for optimizing the diagnostic procedures and making decisions regarding alternative procedures. In addition, the pregnant patient has a right to know the magnitude and type of radiation risks expected as a result of foetus exposure. From a risk perspective epidemiological data has shown that the embryo/foetus together with children experience higher radiation sensitivity in terms of induced leukemia and cancer compared to an adult population. Recent estimates give cancer excess lifetime mortality risks for whole body exposures of children and foetus (0-15 y age) of 0.06% up to 0.14% per 10 mSv. In addition to the risk of cancer induction effects of cell killing, e.g. CNS abnormalities, cataracts, malformations, growth retardation, may occur. However, these effects are believed to have a threshold, about 100-200 mGy, and such foetus doses are rarely reached in diagnostic radiology procedures. There are 2 principal situations where foetus exposures may occur in diagnostic radiology; The pregnancy of the patient is known at the time of examination, but due to the medical indications the examination can not be postponed or put forward in time, and there are no suitable alternative non-radiological procedures. The pregnancy of the patient is not known at the time of examination, either due to the fact that the patient is unaware of her pregnancy or the medical personnel failed to obtain this information. The former situation may occur during the first few weeks from conception, whereas the latter situation may cover a greater gestation period. The frequency of foetus exposure is not well documented. In Sweden, there are well-established routines to track down pregnant patients before examinations are being performed. However, there are no general obligations or routines to document the cases either (i) when

  2. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 11 and 12. Final report

    International Nuclear Information System (INIS)

    Sunde, C.; Pazsit, I.; Demaziere, C.; Dahl, O.; Mileshina, L.

    2006-06-01

    This report describes the results obtained during Stage 11 and 12 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of stage 1 and 2 (SKI Report 95:14 and 96:50). Higher order eigenfunctions and eigenvalues of the diffusion equation, describing a static core, have lost their significance when doing calculations in realistic systems, since there are usually made by nodal methods or other direct numerical techniques. However, there are situations when knowledge of the higher order modes is still useful. Such case is the separation of the global and regional flux oscillations in the case of BWR instability. Another case is the investigation of the stability properties of large inhomogeneous cores, which is usually quantified with the so-called eigenvalue separation, ES=1/k 1 - 1/k 0 where k 0 and k 1 , are the fundamental and first higher order eigenvalues, respectively. Numerical codes used for ICMF calculations usually do not have the option of calculating the higher order eigenvalues and eigenfunctions. In idealised systems, these can be calculated with semi-analytical methods. In order to get insight into the characteristics of the higher order eigenmodes of the neutron flux and the adjoint, these were calculated in a reflected homogeneous system with two-group theory. The adjoint eigenmodes are necessary if an orthogonality property needs to be used, such as the separation of the modes from a flux shape which is a sum of several eigenmodes. At the same time, the so-called numerical noise simulator, developed at the Dept., was extended such that it became suitable for the calculation of the higher order eigenmodes, both direct and adjoint ones. This simulator can treat real inhomogeneous cores, with an input deck compatible with that of SIMULATE. The simulator was used to calculate the eigenfunctions and

  3. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 11 and 12. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sunde, C.; Pazsit, I.; Demaziere, C.; Dahl, O.; Mileshina, L. [Chalmers Univ. of Technology, Goeteborg (Sweden). Dept. of Nuclear Engineering

    2006-06-15

    This report describes the results obtained during Stage 11 and 12 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. The long-term goals are elaborated in more detail in e.g. the Final Reports of stage 1 and 2 (SKI Report 95:14 and 96:50). Higher order eigenfunctions and eigenvalues of the diffusion equation, describing a static core, have lost their significance when doing calculations in realistic systems, since there are usually made by nodal methods or other direct numerical techniques. However, there are situations when knowledge of the higher order modes is still useful. Such case is the separation of the global and regional flux oscillations in the case of BWR instability. Another case is the investigation of the stability properties of large inhomogeneous cores, which is usually quantified with the so-called eigenvalue separation, ES=1/k{sub 1} - 1/k{sub 0} where k{sub 0} and k{sub 1}, are the fundamental and first higher order eigenvalues, respectively. Numerical codes used for ICMF calculations usually do not have the option of calculating the higher order eigenvalues and eigenfunctions. In idealised systems, these can be calculated with semi-analytical methods. In order to get insight into the characteristics of the higher order eigenmodes of the neutron flux and the adjoint, these were calculated in a reflected homogeneous system with two-group theory. The adjoint eigenmodes are necessary if an orthogonality property needs to be used, such as the separation of the modes from a flux shape which is a sum of several eigenmodes. At the same time, the so-called numerical noise simulator, developed at the Dept., was extended such that it became suitable for the calculation of the higher order eigenmodes, both direct and adjoint ones. This simulator can treat real inhomogeneous cores, with an input deck compatible with that of SIMULATE. The simulator was used to calculate the

  4. Evaluation of diagnostic methods for the detection of Helicobacter pylori in gastric biopsy specimens of dyspeptic patients

    Directory of Open Access Journals (Sweden)

    Ivy Bastos Ramis

    2012-09-01

    Full Text Available Helicobacter pylori infects nearly 50% of the world's population. This microorganism is accepted as the most important agent of gastritis and as a risk factor for peptic ulcer disease and gastric adenocarcinoma. Currently many diagnostic methods exist for detecting H. pylori, however they all have limitations, thus it is recommend a combination of at least two methods. The aim of this study was to evaluate diagnostic methods, such as in-house urease test, culture and Polymerase Chain Reaction (PCR, for the detection of the H. pylori in gastric biopsy specimens of 144 dyspeptic patients, using as gold standard the association between histology and rapid urease test. According to the gold standard used in this study, 48 (33.3% patients were infected with H. pylori, while 96 (66.7% were classified as not infected. The in-house urease test and the PCR were the most sensitive methods (100%, followed by culture (85.4%. However, the in-house urease test and the culture were the most specific (100%, followed by PCR (75%. In conclusion, this study showed that, in comparison with the combination of histology and rapid urease test, the in-house urease test and the PCR presented 100% of sensitivity in the diagnosis of gastric infection by H. pylori, while the in-house urease test and the culture reached 100% of specificity. These finding suggest that the combination of two or more methods may improve the accuracy of the H. pylori detection.

  5. A U.S. Forest Service special forest products appraisal system: background, methods, and assessment.

    Science.gov (United States)

    Jerry Smith; Lisa K. Crone; Susan J. Alexander

    2010-01-01

    Increasing concern over the management and harvest of special forest products (SFP) from national forest lands has led to the development of new Forest Service policy directives. In this paper, we present a brief history of SFPs in the Western United States, highlighting the issues that necessitated new management direction. The new policy directives that led to the...

  6. Method for assessing the reliability of molecular diagnostics based on multiplexed SERS-coded nanoparticles.

    Directory of Open Access Journals (Sweden)

    Steven Y Leigh

    Full Text Available Surface-enhanced Raman scattering (SERS nanoparticles have been engineered to generate unique fingerprint spectra and are potentially useful as bright contrast agents for molecular diagnostics. One promising strategy for biomedical diagnostics and imaging is to functionalize various particle types ("flavors", each emitting a unique spectral signature, to target a large multiplexed panel of molecular biomarkers. While SERS particles emit narrow spectral features that allow them to be easily separable under ideal conditions, the presence of competing noise sources and background signals such as detector noise, laser background, and autofluorescence confounds the reliability of demultiplexing algorithms. Results obtained during time-constrained in vivo imaging experiments may not be reproducible or accurate. Therefore, our goal is to provide experimentalists with a metric that may be monitored to enforce a desired bound on accuracy within a user-defined confidence level. We have defined a spectral reliability index (SRI, based on the output of a direct classical least-squares (DCLS demultiplexing routine, which provides a measure of the reliability of the computed nanoparticle concentrations and ratios. We present simulations and experiments to demonstrate the feasibility of this strategy, which can potentially be utilized for a range of instruments and biomedical applications involving multiplexed SERS nanoparticles.

  7. A Novel Diagnostic Method to Detect Duck Tembusu Virus: A Colloidal Gold-Based Immunochromatographic Assay

    Directory of Open Access Journals (Sweden)

    Guanliu Yu

    2018-05-01

    Full Text Available Duck Tembusu virus (DTMUV is an emerging pathogenic flavivirus that has resulted in large economic losses to the duck-rearing industry in China since 2010. Therefore, an effective diagnostic approach to monitor the spread of DTMUV is necessary. Here, a novel diagnostic immunochromatographic strip (ICS assay was developed to detect DTMUV. The assay was carried out using colloidal gold coated with purified monoclonal antibody A12D3 against envelope E protein. Purified polyclonal C12D1 antibodies from BALB/c mice against the envelope E protein were used as the capture antibody. Goat anti-mouse IgG was used to detect DTMUV, which was also assembled on the ICS. Results showed that the ICS could specifically detect DTMUV within 10 min. It also could be stored 25 and 4°C for 4 and 6 months, respectively. The sensitivity of the ICS indicated that the dilution multiples of positive allantoic fluid of DTMUV (LD50: 104.33/0.2 ml was up to 200. Its specificity and sensibility showed no significant change under the above storage situations. Fifty clinical samples were simultaneously detected by ICS and reverse-transcription polymerase chain reaction with a 93.9% coincidence rate between them. It proved that the ICS in the present study was highly specific, sensitive, repeatable, and more convenient to rapidly detect DTMUV in clinical samples.

  8. A comparative assessment of the value of imaging methods in diagnostic of osteonecrosis of the femoral head in adults

    International Nuclear Information System (INIS)

    Peshev, A.; Mlachkova, D.; Mlachkov, N.

    2006-01-01

    Full text: The aim of the presentation is to study the possibilities of contemporary methods for early diagnosis of osteonecrosis of the femoral head in adults with a view to make a suitable diagnostic protocol. 156 hip joints were examined. A conventional radiography was performed in all, CT - in 112, bone scan - in 123, MRI - in 42. The findings of the imaging methods were compared. The results of imaging methods were put together with the extension of the clinical complaints. The findings of conventional radiography were classified according to Ficat and Arlet, CT findings were classified according to Magit. The size and location of the necrotic area as a prognostic factor was evaluated. MRI was the most sensitive method in the early stages of necrosis of femoral head, followed by bone scan and CT. Conventional radiography is suitable for late stages of osteonecrosis. On the basis of our investigations we propose a diagnostic protocol for early diagnosis of osteonecrosis of the femoral head in adults

  9. A hybrid body technique: does the pulse diagnostic cun guan chi method have Chinese-Tibetan origins?

    Science.gov (United States)

    Hsu, Elisabeth

    2008-01-01

    This article investigates the medieval origins of the main pulse diagnostic method in contemporary Chinese medicine, sometimes known as san bu (three sectors) method, which requires physicians to examine the mai (vessels, vessel movements or pulse) on the wrist at the three locations cun guan chi (inch, gate, foot). The article provides evidence to suggest that this body technique grew out of an earlier Chinese one, the cun chi (inch-foot) method, which appears to have aimed at investigating the qualities of yin and yang in order to determine the condition of a patient by means of exploring fairly large areas of the patient's body surface with the palms. The article furthermore posits that the cun chi method was decisively transformed in medieval times, presumably due to the impact of early Tibetan pulse diagnostic practices: it became framed in a numerology of three and started advocating the use of the fingertips for sensing the pulse beats. The article, which draws on detailed textual analyses of medieval manuscripts, on visual evidence and also on psychophysical research, furthermore highlights how misunderstandings can constructively contribute to cultural communication.

  10. Comparison between different methods of magnetic field diagnostics in beam emission spectroscopy

    International Nuclear Information System (INIS)

    Voslamber, D.

    1995-01-01

    Magnetic field diagnostics in tokamaks using the motional Stark effect in fast neutral beams have been based on two kinds of polarimetry which are called 'static' and 'dynamic'. It is shown that static polarimetry presents a number of advantages over dynamic polarimetry, provided it is made complete in the sense that a sufficient number of polarisation analysers is installed and different parts of the spectrum are explored to yield full information on the set of unknowns inherent in the problem. A detailed scheme of self-calibrating static polarimetry is proposed, including the case where an in-vessel mirror with changing characteristics (coating by impurities) is placed in front of the optical detection system. (author) 5 refs.; 2 figs

  11. Image processing methods for noise reduction in the TJ-II Thomson Scattering diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Dormido-Canto, S., E-mail: sebas@dia.uned.es [Departamento de Informatica y Automatica, UNED, Madrid 28040 (Spain); Farias, G. [Pontificia Universidad Catolica de Valparaiso, Valparaiso (Chile); Vega, J.; Pastor, I. [Asociacion EURATOM/CIEMAT para Fusion, Madrid 28040 (Spain)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We describe an approach in order to reduce or mitigate the stray-light on the images and show the exceptional results. Black-Right-Pointing-Pointer We analyze the parameters to take account in the proposed process. Black-Right-Pointing-Pointer We report a simplified exampled in order to explain the proposed process. - Abstract: The Thomsom Scattering diagnostic of the TJ-II stellarator provides temperature and density profiles. The CCD camera acquires images corrupted with noise that, in some cases, can produce unreliable profiles. The main source of noise is the so-called stray-light. In this paper we describe an approach that allows mitigation of the effects that stray-light has on the images: extraction regions with connected-components. In addition, the robustness and effectiveness of the noise reduction technique is validated in two ways: (1) supervised classification and (2) comparison of electron temperature profiles.

  12. Light extinction method for diagnostics of particles sizes formed in magnetic field

    Science.gov (United States)

    Myshkin, Vyacheslav; Izhoykin, Dmitry; Grigoriev, Alexander; Gamov, Denis; Leonteva, Daria

    2018-03-01

    The results of laser diagnostics of dispersed particles formed upon cooling of Zn vapor are presented. The radiation attenuation in the wavelength range 420-630 nm with a step of 0.3 nm was registered. The attenuation coefficients spectral dependence was processed using known algorithms for integral equation solving. The 10 groups of 8 attenuation coefficients were formed. Each group was processed taking with considering of previous decisions. After processing of the 10th group of data, calculations were repeated from the first one. Data of the particles sizes formed in a magnetic field of 0, 44 and 76 mT are given. A model of physical processes in a magnetic field is discussed.

  13. Prevalence of Coxiella Burnetii in Dairy Herds - Diagnostic Methods and Risk to Humans - A Review

    Directory of Open Access Journals (Sweden)

    Szymańska-Czerwińska Monika

    2014-10-01

    Full Text Available Q fever is a zoonotic disease caused by Coxiella burnetii. The main source of infection are ruminants (cattle, sheep, and goats. C. burnetii is excreted via birth products, vaginal mucus, milk, and faeces. Raw milk is considered useful for epidemiological examinations of animals and evaluation of infection dynamics at the herd level. This article summarises data on prevalence studies on C. burnetii in bulk-tank milk in different European countries with the means of serological tests and PCR. It also summarises the results of studies to evaluate the actual risk of disease transmission to humans through consumption of raw milk. Moreover, the available diagnostic tools for detection C. burnetii infection are presented.

  14. Improved data acquisition methods for uninterrupted signal monitoring and ultra-fast plasma diagnostics in LHD

    International Nuclear Information System (INIS)

    Nakanishi, Hideya; Imazu, Setsuo; Ohsuna, Masaki

    2012-01-01

    To deal with endless data streams acquired in LHD steady-state experiments, the LHD data acquisition system was designed with a simple concept that divides a long pulse into a consecutive series of 10-s “subshots”. Latest digitizers applying high-speed PCI-Express technology, however, output nonstop gigabyte per second data streams whose subshot intervals would be extremely long if 10-s rule was applied. These digitizers need shorter subshot intervals, less than 10-s long. In contrast, steady-state fusion plants need uninterrupted monitoring of the environment and device soundness. They adopt longer subshot lengths of either 10 min or 1 day. To cope with both uninterrupted monitoring and ultra-fast diagnostics, the ability to vary the subshot length according to the type of operation is required. In this study, a design modification that enables variable subshot lengths was implemented and its practical effectiveness in LHD was verified. (author)

  15. A Method to Assess Transverse Vibration Energy of Ship Propeller Shaft for Diagnostic Purposes

    Directory of Open Access Journals (Sweden)

    Korczewski Zbigniew

    2017-12-01

    Full Text Available The article discusses a key problem of ship propulsion system vibration diagnostics, which concerns assessing this part of mechanical energy transmitted from the main engine to the ship propeller which is dissipated due to propeller shaft vibration. A simplified calculation model is proposed which allows the total energy of the generated torsional vibration to be assessed from the shaft deflection amplitude measured at the mind-span point between the supports. To verify the developed model, pilot tests were performed on the laboratory rotational mechanical system test rig. In those tests, cyclic bending moment was applied to a unified (cylindrical material sample, which modelled, at an appropriate scale, structural and functional properties of a real propeller shaft.

  16. Potential application of new diagnostic methods for controlling bovine Tuberculosis in Brazil

    Directory of Open Access Journals (Sweden)

    Luciana dos Santos Medeiros

    2010-10-01

    Full Text Available Bovine tuberculosis, a chronic infection in cattle caused by Mycobacterium bovis, remains an economic and public health problem for several countries. Due to its economic impact on international trade, contagious nature, and implications for human health, global programs to eradicate the disease were implemented worldwide. Those programs are based on slaughtering PPD-reactive animals. Despite the National Programs in Brazil, complete eradication has not been achieved, and the disease remains, albeit at a lower prevalence. The central purpose of this review is to address diagnostic tests for tuberculosis. Considering the course of the infection in cattle, at least two tests, ideally complementary to one another, may be necessary for an adequate diagnosis: the first based on the cellular response, and the second capable of identifying anergic animals by detection of specific anti-M.bovis antibodies.

  17. Nanotechnology solutions for Alzheimer's disease: advances in research tools, diagnostic methods and therapeutic agents.

    Science.gov (United States)

    Nazem, Amir; Mansoori, G Ali

    2008-03-01

    A century of research has passed since the discovery and definition of Alzheimer's disease (AD), the primary common dementing disorder worldwide. However, AD lacks definite diagnostic approaches and effective cure at the present. Moreover, the currently available diagnostic tools are not sufficient for an early screening of AD in order to start preventive approaches. Recently the emerging field of nanotechnology has promised new techniques to solve some of the AD challenges. Nanotechnology refers to the techniques of designing and manufacturing nanosize (1-100 nm) structures through controlled positional and/or self-assembly of atoms and molecules. In this report, we present the promises that nanotechnology brings in research on the AD diagnosis and therapy. They include its potential for the better understanding of the AD root cause molecular mechanisms, AD's early diagnoses, and effective treatment. The advances in AD research offered by the atomic force microscopy, single molecule fluorescence microscopy and NanoSIMS microscopy are examined here. In addition, the recently proposed applications of nanotechnology for the early diagnosis of AD including bio-barcode assay, localized surface plasmon resonance nanosensor, quantum dot and nanomechanical cantilever arrays are analyzed. Applications of nanotechnology in AD therapy including neuroprotections against oxidative stress and anti-amyloid therapeutics, neuroregeneration and drug delivery beyond the blood brain barrier (BBB) are discussed and analyzed. All of these applications could improve the treatment approach of AD and other neurodegenerative diseases. The complete cure of AD may become feasible by a combination of nanotechnology and some other novel approaches, like stem cell technology.

  18. Evaluation of a special pencil ionization chamber by the Monte Carlo method

    International Nuclear Information System (INIS)

    Mendonca, Dalila; Neves, Lucio P.; Perini, Ana P.

    2015-01-01

    A special pencil type ionization chamber, developed at the Instituto de Pesquisas Energeticas e Nucleares, was characterized by means of Monte Carlo simulation to determine the influence of its components on its response. The main differences between this ionization chamber and commercial ionization chambers are related to its configuration and constituent materials. The simulations were made employing the MCNP-4C Monte Carlo code. The highest influence was obtained for the body of PMMA: 7.0%. (author)

  19. Use of Special Operations Forces in United Nations Missions: a Method to Resolve Complexity

    Science.gov (United States)

    2015-05-21

    physical stamina and psychological stability, followed by a rigorous training program are the imperatives to create SOF soldiers.42 Mark Bowden in...recommendation is that the United Nations should establish a Special Operations planning cell within the UN Department of Peacekeeping Operations. As of...now, the cell is nonexistent. This cell should be able to facilitate the integration of SOF into the overall peace operations concept. Finally, the

  20. Diagnostic abilities of three CAD methods for assessing microcalcifications in mammograms and an aspect of equivocal cases decisions by radiologists

    International Nuclear Information System (INIS)

    Hung, W.T.; Nguyen, H.T.; Thornton, B.S.; Rickard, M.T.; Blinowska, A.

    2003-01-01

    Radiologists use an 'Overall impression' rating to assess a suspicious region on a mammogram. The value ranges from 1 to 5. They will definitely send a patient for biopsy if the rating is 4 or 5. They will send the patient for core biopsy when a rating of 3 (indeterminate) is given. We have developed three methods to aid diagnosis of cases with microcalcifications. The first two methods, namely, Bayesian and multiple logistic regression (with a special 'cutting score' technique), utilise six parameter ratings which minimise subjectivity in characterising the microcalcifications. The third method uses three parameters (age of patient, uniformity of size of microcalcification and their distribution) in a multiple stepwise regression. For both training set and test set, all three methods are as good as the two radiologists in terms of percentages of correct classification. Therefore, all three proposed methods potentially can be used as second readers. Copyright (2003) Australasian College of Physical Scientists and Engineers in Medicine

  1. 201Tl myocard scintigraphy - a specialized non-invasive method in evaluating myocardial function

    International Nuclear Information System (INIS)

    Birke, S.; Deckart, H.; Mischke, W.; Schulz, J.; Koblitz, E.

    1985-01-01

    In 216 patients with ischemic heart disease (IHK) or with angina pectoris symptoms and suspected IHK the results of resting electrocardiograms were compared with those of 201 Tl scintigraphy under conditions of rest and exercise, resp. 201 Tl scintigraphy proved to be superior in sensitivity and specifity to the electrocardiograms of rest and under exercise as to the detection of coronary heart disease, the localization and assessment of the severity of coronary heart disease, and the evidence of load ischemia. Conclusions are drawn for a program of consecutive diagnostic steps in suspected IHK as well as for the evaluation of myocardial function in known IHK. (author)

  2. DIAGNOSTIC CARDIAC CATHETERIZATION USING THE MEDRAD AVANTA FLUID MANAGEMENT SYSTEM AS COMPARED TO THE TRADITIONAL MANUAL INJECTION METHOD

    Energy Technology Data Exchange (ETDEWEB)

    Winniford, Michael D

    2013-02-08

    smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study

  3. A survey of methods used for antimicrobial susceptibility testing in veterinary diagnostic laboratories in the United States.

    Science.gov (United States)

    Dargatz, David A; Erdman, Matthew M; Harris, Beth

    2017-09-01

    Antimicrobial resistance is a serious threat to animal and human health worldwide, requiring a collaborative, holistic approach. The U.S. Government has developed a national strategy to address antimicrobial resistance, with one component being to monitor antimicrobial resistance in agricultural settings. We developed a survey to collect information about antimicrobial susceptibility testing (AST) from the veterinary diagnostic laboratory community in the United States, assessing current practices and technologies and determining how AST information is shared. Of the 132 surveys administered, 52 (39%) were returned. Overall, responding laboratories conducted susceptibility tests on 98,788 bacterial isolates in 2014, with Escherichia coli being the most common pathogen tested across all animal species. The 2 most common AST methods employed were the disk diffusion method (71%) and the Sensititre platform broth microdilution system (59%). Laboratories primarily used the Clinical Laboratory Standards Institute (CLSI) VET-01 standard (69%) and the automatically calculated interpretations provided by the commercial AST systems (61%) for interpreting their AST data. Only 22% of laboratories published AST data on a periodic basis, usually via annual reports published on the laboratory's website or through peer-reviewed journals for specific pathogens. Our results confirm that disk diffusion and broth microdilution remain the standard AST methods employed by U.S. veterinary diagnostic laboratories, and that CLSI standards are commonly used for interpreting AST results. This information will help determine the most efficient standardized methodology for future surveillance. Furthermore, the current infrastructure within laboratories, once harmonized, will help provide a mechanism for conducting national surveillance programs.

  4. Appropriate statistical methods are required to assess diagnostic tests for replacement, add-on, and triage

    NARCIS (Netherlands)

    Hayen, Andrew; Macaskill, Petra; Irwig, Les; Bossuyt, Patrick

    2010-01-01

    To explain which measures of accuracy and which statistical methods should be used in studies to assess the value of a new binary test as a replacement test, an add-on test, or a triage test. Selection and explanation of statistical methods, illustrated with examples. Statistical methods for

  5. Evaluation of diagnostic tests when there is no gold standard. A review of methods

    NARCIS (Netherlands)

    Rutjes, A. W. S.; Reitsma, J. B.; Coomarasamy, A.; Khan, K. S.; Bossuyt, P. M. M.

    2007-01-01

    OBJECTIVE: To generate a classification of methods to evaluate medical tests when there is no gold standard. METHODS: Multiple search strategies were employed to obtain an overview of the different methods described in the literature, including searches of electronic databases, contacting experts

  6. Development of monitoring and diagnostic methods for robots used in remediation of waste sites. 1997 annual progress report

    International Nuclear Information System (INIS)

    Tecza, J.

    1998-01-01

    'Safe and efficient clean up of hazardous and radioactive waste sites throughout the DOE complex will require extensive use of robots. This research effort focuses on developing Monitoring and Diagnostic (M and D) methods for robots that will provide early detection, isolation, and tracking of impending faults before they result in serious failure. The utility and effectiveness of applying M and D methods to hydraulic robots has never been proven. The present research program is utilizing seeded faults in a laboratory test rig that is representative of an existing hydraulically-powered remediation robot. This report summarizes activity conducted in the first 9 months of the project. The research team has analyzed the Rosie Mobile Worksystem as a representative hydraulic robot, developed a test rig for implanted fault testing, developed a test plan and agenda, and established methods for acquiring and analyzing the test data.'

  7. Specialized Finite Set Statistics (FISST)-Based Estimation Methods to Enhance Space Situational Awareness in Medium Earth Orbit (MEO) and Geostationary Earth Orbit (GEO)

    Science.gov (United States)

    2016-08-17

    Specialized Finite Set Statistics (FISST)-based Estimation Methods to Enhance Space Situational Awareness in Medium Earth Orbit (MEO) and Geostationary...terms of specialized Geostationary Earth Orbit (GEO) elements to estimate the state of resident space objects in the geostationary regime. Justification...AFRL-RV-PS- AFRL-RV-PS- TR-2016-0114 TR-2016-0114 SPECIALIZED FINITE SET STATISTICS (FISST)- BASED ESTIMATION METHODS TO ENHANCE SPACE SITUATIONAL

  8. Features of the diagnostic methods to identify the sheep subclinical mastitis in according to infectious etiology

    Directory of Open Access Journals (Sweden)

    Eliane Vale Tanaka

    2012-12-01

    Full Text Available Mastitis is an infection of the mammary gland mainly caused by bacteria. In sheep, besides it causes chemical and physical changes in milk with the loss in quality, mastitis changes the glandular tissue which may lead to premature cull-out from the herd. This study aimed to evaluate the diagnostic features of the California Mastitis Test (CMT and somatic cell count (SCC to the identification of subclinical mastitis in sheep according to the micro-organisms isolated. The work is at an early stage and CMT was performed in all ewes. It was considered positive results all degrees of reaction, while the negative reaction was considered when there was not viscosity. Subsequently, samples were collected aseptically from milk and were sent for microbiological analysis. A total of 160 milk samples were analyzed from 85 Santa Inês sheep belonging to the Embrapa Southeast Livestock in São Carlos, São Paulo. Samples were plated on sheep blood agar to 5% and incubated for 24h/72h at 35 ° C. In samples with growth, tests to the identification of the microorganisms were performed, macroscopic characteristics of the colonies and the production or absence of hemolysis, Gram staining, catalase test, coagulase test with rabbit plasma and verification of acetoin production. The sensitivity of the diagnostic tests were determined in accordance to the ratio of the positive tests and the presence of the disease, while the specificities were calculated according to the ratio of the negative results and the absence of disease. The efficiency was based on the percentage of true results that the test was able to provide diagnosis. SCC in milk was determined using the somatic cell count Somacount 300 (Bentley and the presence of the disease was given when isolated coagulase-positive staphylococci (CPS, coagulase-negative staphylococci (CNS, coliforms and other microorganisms (Corinebacteria, strep and association of two bacteria in a same sample. It was used the limit

  9. Molecular methods for the detection of human papillomavirus infection: new insights into their role in diagnostics and epidemiological surveillance

    Directory of Open Access Journals (Sweden)

    Andrea Piana

    2009-06-01

    Full Text Available Human papillomaviruses (HPVs comprise more than 180 genotypes. HPV infection is mainly diagnosed by molecular methods. The aim of our study was to review the main molecular methods used to diagnose HPV infection, underscoring their characteristics. Several methods have been developed for molecular diagnosis of Papilloma infection, such as those based on PCR technique. Another commercial non-PCR based diagnostic method is Hybrid Capture test; it is the only commercially available HPV DNA detection test approved by the FDA. Several Authors have suggested that viral load and E6/E7 transcripts could be used as surrogate markers of persistent HPV infection, being more specific predictors of progressive disease than the simple presence of HPV DNA. Validating clinical sensitivity and specificity of each technique and improving the interpretation of the results are essential; consequently, there is a clear need for well characterized international quality control panels to compare the various diagnostic methods. HPV DNA testing could be useful both as a primary screening test, alone or in combination with a Pap smear, for the early detection of cervical cancer precursors, and as triage test to select women with minor cytological abnormalities who will need further follow-up and to predict possible treatment failure in women with diagnosed high-grade intraepithelial lesions who have undergone excisional therapy. In the next future surveillance for HPV infections, based on these molecular methods, could represent an important step for the development of primary and secondary prophylactic interventions, such as new vaccines targeted to genotypes who might replace those previously prevalent.

  10. Assessing the special need for protection of vulnerable refugees: testing the applicability of a screening method (RHS-15) to detect traumatic disorders in a refugee sample in Germany.

    Science.gov (United States)

    Stingl, Markus; Knipper, Michael; Hetzger, Björge; Richards, Jessica; Yazgan, Bülent; Gallhofer, Bernd; Hanewald, Bernd

    2017-10-29

    Although EU member states are obligated to take special account of the situation of particularly vulnerable refugees, appropriate and specific measures to detect affected asylum seekers are not yet available. This study tries to pave the way for the implementation of an adequate instrument which at the same time assesses these needs of suffering people whilst responding to the need for mental health assessments specifically designed for refugees. This was done by testing the implementation of a screening method (Refugee Health Screener RHS-15) for trauma related mental health problems in refugees. Two refugee samples in Germany (differing in arrival time: 126 applicants for asylum residing in the initial reception center and 116 living in long term communal accommodations) were assessed with the culturally sensitive Refugee Health Screener (RHS-15) to detect the incidence of mental health problems amongst them. Test fairness, reasonableness, susceptibility, transparency, acceptance, external design, utility and economy of the instrument were examined to check the applicability of the RHS-15 standardization test. The RHS-15 indicates a good practical feasibility as the examination of the focused psychometric characteristics suggests. It became apparent, that implementing a screening procedure depends on political, legal and medical context factors that need to be considered. 2/3 of the participants had a positive screening result, which needs further diagnostic clarification in a second step. The RHS-15 seems to be practicable, economical, and rapidly deployable for the widespread detection of traumatic disorders in refugees living in Europe. The tool proved useful to aid diagnostic assessments and provide treatment to individuals in need, however the time of examination (resp. the duration of staying in the target land) influences the results.

  11. Multi-method analysis of MRI images in early diagnostics of Alzheimer's disease.

    Directory of Open Access Journals (Sweden)

    Robin Wolz

    Full Text Available The role of structural brain magnetic resonance imaging (MRI is becoming more and more emphasized in the early diagnostics of Alzheimer's disease (AD. This study aimed to assess the improvement in classification accuracy that can be achieved by combining features from different structural MRI analysis techniques. Automatically estimated MR features used are hippocampal volume, tensor-based morphometry, cortical thickness and a novel technique based on manifold learning. Baseline MRIs acquired from all 834 subjects (231 healthy controls (HC, 238 stable mild cognitive impairment (S-MCI, 167 MCI to AD progressors (P-MCI, 198 AD from the Alzheimer's Disease Neuroimaging Initiative (ADNI database were used for evaluation. We compared the classification accuracy achieved with linear discriminant analysis (LDA and support vector machines (SVM. The best results achieved with individual features are 90% sensitivity and 84% specificity (HC/AD classification, 64%/66% (S-MCI/P-MCI and 82%/76% (HC/P-MCI with the LDA classifier. The combination of all features improved these results to 93% sensitivity and 85% specificity (HC/AD, 67%/69% (S-MCI/P-MCI and 86%/82% (HC/P-MCI. Compared with previously published results in the ADNI database using individual MR-based features, the presented results show that a comprehensive analysis of MRI images combining multiple features improves classification accuracy and predictive power in detecting early AD. The most stable and reliable classification was achieved when combining all available features.

  12. Novel readout method for molecular diagnostic assays based on optical measurements of magnetic nanobead dynamics.

    Science.gov (United States)

    Donolato, Marco; Antunes, Paula; Bejhed, Rebecca S; Zardán Gómez de la Torre, Teresa; Østerberg, Frederik W; Strömberg, Mattias; Nilsson, Mats; Strømme, Maria; Svedlindh, Peter; Hansen, Mikkel F; Vavassori, Paolo

    2015-02-03

    We demonstrate detection of DNA coils formed from a Vibrio cholerae DNA target at picomolar concentrations using a novel optomagnetic approach exploiting the dynamic behavior and optical anisotropy of magnetic nanobead (MNB) assemblies. We establish that the complex second harmonic optical transmission spectra of MNB suspensions measured upon application of a weak uniaxial AC magnetic field correlate well with the rotation dynamics of the individual MNBs. Adding a target analyte to the solution leads to the formation of permanent MNB clusters, namely, to the suppression of the dynamic MNB behavior. We prove that the optical transmission spectra are highly sensitive to the formation of permanent MNB clusters and, thereby to the target analyte concentration. As a specific clinically relevant diagnostic case, we detect DNA coils formed via padlock probe recognition and isothermal rolling circle amplification and benchmark against a commercial equipment. The results demonstrate the fast optomagnetic readout of rolling circle products from bacterial DNA utilizing the dynamic properties of MNBs in a miniaturized and low-cost platform requiring only a transparent window in the chip.

  13. Nucleic acid probes as a diagnostic method for tick-borne hemoparasites of veterinary importance.

    Science.gov (United States)

    Figueroa, J V; Buening, G M

    1995-03-01

    An increased number of articles on the use of nucleic acid-based hybridization techniques for diagnostic purposes have been recently published. This article reviews nucleic acid-based hybridization as an assay to detect hemoparasite infections of economic relevance in veterinary medicine. By using recombinant DNA techniques, selected clones containing inserts of Anaplasma, Babesia, Cowdria or Theileria genomic DNA sequences have been obtained, and they are now available to be utilized as specific, highly sensitive DNA or RNA probes to detect the presence of the hemoparasite DNA in an infected animal. Either in an isotopic or non-isotopic detection system, probes have allowed scientists to test for--originally in samples collected from experimentally infected animals and later in samples collected in the field--the presence of hemoparasites during the prepatent, patent, convalescent, and chronic periods of the infection in the host. Nucleic acid probes have given researchers the opportunity to carry out genomic analysis of parasite DNA to differentiate hemoparasite species and to identify genetically distinct populations among and within isolates, strains and clonal populations. Prevalence of parasite infection in the tick vector can now be accomplished more specifically with the nucleic acid probes. Lately, with the advent of the polymerase chain reaction technique, small numbers of hemoparasites can be positively identified in the vertebrate host and tick vector. These techniques can be used to assess the veterinary epidemiological situation in a particular geographical region for the planning of control measures.

  14. Computations of zeros of special functions and eigenvalues of differential equations by matrix method

    OpenAIRE

    Miyazaki, Yoshinori

    2000-01-01

    This paper is strongly based on two powerful general theorems proved by Ikebe, et. al in 1993[15] and 1996[13], which will be referred to as Theorem A and Theorem B in this paper. They were recently published and justify the approximate computations of simple eigenvalues of infinite matrices of certain types by truncation, giving an extremely accurate error estimates. So far, they have applied to some important problems in engineering, such as computing the zeros of some special functions, an...

  15. Methods of generalizing and classifying layer structures of a special form

    Energy Technology Data Exchange (ETDEWEB)

    Viktorova, N P

    1981-09-01

    An examination is made of the problem of classifying structures represented by weighted multilayer graphs of special form with connections between the vertices of each layer. The classification of structures of such a form is based on the construction of resolving sets of graphs as a result of generalization of the elements of the training sample of each class and the testing of whether an input object is isomorphic (with allowance for the weights) to the structures of the resolving set or not. 4 references.

  16. New labeling and separation methods for in vivo and in vitro diagnostics in Hungary

    International Nuclear Information System (INIS)

    Veres, A.; Toth, G.; Zsinka, L.; Miller, J.

    1986-01-01

    Three methods have been developed: 1. An adsorption chromatographic method for the separation of iodine-125-labeled compounds applied as tracers in the radioimmunoassay; 2. A portable sublimation generator for the separation of technetium-99m from low or medium specific activity molybdenum-99 using titanium molybdate as a new target material; 3. A novel dry distillation method for the production of iodine-131 from melted, pile-irradiated TeO 2 . The method renders possible to get rid of liquid radioactive wastes. 1 reference

  17. Clinical value of FDG hybrid-PET in staging and restaging of malignant lymphoma. Compared with conventional diagnostic methods

    International Nuclear Information System (INIS)

    Pichler, R.; Maschek, W.; Hatzl-Griesenhofer, M.; Huber, H.; Wimmer, G.; Wahl, G.; Fridrik, M.

    2000-01-01

    Aim of the present retrospective study was to validate the clinical value of F-18-FDG PET imaging in lymphoma patients with a dual head camera modified for coincidence detection. Staging before and after oncological treatment was compared with a conservative diagnostic approach. Methods: 48 patients (28 non-Hodgkin lymphoma, 20 Hodgkin's disease) received FDG-Hybrid-PET scans. Pretherapeutic staging was realized in 28 patients, 9 of them had control studies after they had completed therapy. Totally 29 persons were examined for posttherapeutic restaging. Computed tomography imaging and lymph node sonography was performed in all cases. Results were validated by clinical follow-up, in three cases a recidive was proven by biopsy. Results: CT and ultrasound detected 77 lesions in 28 patients compared with 100 visualized by PET, but this difference in pretherapeutic staging did not reach significance at p>0.05 by Fisher's t-test. Hybrid-PET obtained a sensitivity of 93%, a specifity of 79%, a positive of 82% and a negative predictive value of 92% for detection of residual disease. The values for CT+US were 87%, 64%, 72% and 88% respectively. Conclusion: FDG Hybrid-PET is as or even more accurate than standard morphologic diagnostic methods for prestaging in malignant lymphoma. Additionally, there is a substancial benefit for therapy monitoring of residual disease using coincidence detection PET with a 3/4-inch crystal gamma camera. (orig.) [de

  18. Numerical Modelling of the Special Light Source with Novel R-FEM Method

    Directory of Open Access Journals (Sweden)

    Pavel Fiala

    2008-01-01

    Full Text Available This paper presents information about new directions in the modelling of lighting systems, and an overview of methods for the modelling of lighting systems. The novel R-FEM method is described, which is a combination of the Radiosity method and the Finite Elements Method (FEM. The paper contains modelling results and their verification by experimental measurements and by the Matlab simulation for this R-FEM method.

  19. Plasma diagnostics for tokamaks and stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Stott, P E; Sanchez, J

    1994-07-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: Magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Scattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma. (Author) 451 refs.

  20. Plasma diagnostics for tokamaks and stellarators

    International Nuclear Information System (INIS)

    Stott, P.E.; Sanchez, J.

    1994-01-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Sattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma

  1. Determining skeletal maturation stage using cervical vertebrae: evaluation of three diagnostic methods

    Directory of Open Access Journals (Sweden)

    Luci Mara Fachardo Jaqueira

    2010-12-01

    Full Text Available The aim of the present study was to compare the use of three cervical vertebral evaluation methods (Hassel-Farman, Baccetti et al., and Seedat-Forsberg for determinating skeletal maturation stage in orthodontic patients. Twenty-three radiographs were randomly selected from a private orthodontic practice. Each radiograph was analyzed on three separate occasions by four evaluators (one radiologist and three orthodontists, who determined the skeletal maturation stage using the references established by each of the three methods. Intraevaluator and interevaluator comparisons were performed, and the degree of agreement was established using the weighted Kappa coefficient (95% CI. Good agreement (Kappa between 0.61 and 0.80 was observed between the determinations of most of the evaluators. The three methods demonstrated clinical applicability. However, the method proposed by Baccetti et al. achieved the best results, followed by the Hassel-Farman and the Seedat-Forsberg methods.

  2. The diagnostic accuracy of serologic and molecular methods for detecting visceral leishmaniasis in HIV infected patients: meta-analysis.

    Directory of Open Access Journals (Sweden)

    Gláucia Fernandes Cota

    Full Text Available BACKGROUND: Human visceral leishmaniasis (VL, a potentially fatal disease, has emerged as an important opportunistic condition in HIV infected patients. In immunocompromised patients, serological investigation is considered not an accurate diagnostic method for VL diagnosis and molecular techniques seem especially promising. OBJECTIVE: This work is a comprehensive systematic review and meta-analysis to evaluate the accuracy of serologic and molecular tests for VL diagnosis specifically in HIV-infected patients. METHODS: Two independent reviewers searched PubMed and LILACS databases. The quality of studies was assessed by QUADAS score. Sensitivity and specificity were pooled separately and compared with overall accuracy measures: diagnostic odds ratio (DOR and symmetric summary receiver operating characteristic (sROC. RESULTS: Thirty three studies recruiting 1,489 patients were included. The following tests were evaluated: Immunofluorescence Antibody Test (IFAT, Enzyme linked immunosorbent assay (ELISA, immunoblotting (Blot, direct agglutination test (DAT and polimerase chain reaction (PCR in whole blood and bone marrow. Most studies were carried out in Europe. Serological tests varied widely in performance, but with overall limited sensitivity. IFAT had poor sensitivity ranging from 11% to 82%. DOR (95% confidence interval was higher for DAT 36.01 (9.95-130.29 and Blot 27.51 (9.27-81.66 than for IFAT 7.43 (3.08-1791 and ELISA 3.06 (0.71-13.10. PCR in whole blood had the highest DOR: 400.35 (58.47-2741.42. The accuracy of PCR based on Q-point was 0.95; 95%CI 0.92-0.97, which means good overall performance. CONCLUSION: Based mainly on evidence gained by infection with Leishmania infantum chagasi, serological tests should not be used to rule out a diagnosis of VL among the HIV-infected, but a positive test at even low titers has diagnostic value when combined with the clinical case definition. Considering the available evidence, tests based on DNA

  3. Evaluation of three different methods of distance learning for postgraduate diagnostic imaging education: A pilot study.

    Science.gov (United States)

    Poirier, Jean-Nicolas; Cooley, Jeffrey R; Wessely, Michelle; Guebert, Gary M; Petrocco-Napuli, Kristina

    2014-10-01

    Objective : The purpose of this study was to evaluate the perceived effectiveness and learning potential of 3 Web-based educational methods in a postgraduate radiology setting. Methods : Three chiropractic radiology faculty from diverse geographic locations led mini-courses using asynchronous discussion boards, synchronous Web conferencing, and asynchronous voice-over case presentations formatted for Web viewing. At the conclusion of each course, participants filled out a 14-question survey (using a 5-point Likert scale) designed to evaluate the effectiveness of each method in achieving specified course objectives and goals and their satisfaction when considering the learning potential of each method. The mean, standard deviation, and percentage agreements were tabulated. Results : Twenty, 15, and 10 participants completed the discussion board, Web conferencing, and case presentation surveys, respectively. All educational methods demonstrated a high level of agreement regarding the course objective (total mean rating >4.1). The case presentations had the highest overall rating for achieving the course goals; however, all but one method still had total mean ratings >4.0 and overall agreement levels of 70%-100%. The strongest potential for interactive learning was found with Web conferencing and discussion boards, while case presentations rated very low in this regard. Conclusions : The perceived effectiveness in achieving the course objective and goals was high for each method. Residency-based distance education may be a beneficial adjunct to current methods of training, allowing for international collaboration. When considering all aspects tested, there does not appear to be a clear advantage to any one method. Utilizing various methods may be most appropriate.

  4. A novel diagnostic method (spectral computed tomography of sacroiliac joints) for axial spondyloarthritis.

    Science.gov (United States)

    Zhang, Ping; Yu, Kai Hu; Guo, Rui Min; Ran, Jun; Liu, Yao; Morelli, John; Runge, Val M; Li, Xiao Ming

    2016-08-01

    To evaluate the diagnostic value of spectral computed tomography (CT) of sacroiliac joints for axial spondyloarthritis (SpA). We retrospectively analyzed the records of 125 patients with low back pain (LBP) suspected of having SpA. Each patient underwent sacroiliac joint spectral CT examination. Water- and calcium-based material decomposition images were reconstructed. After 3-6 months of follow-up, 76 were diagnosed with SpA, and the remaining 49 patients were diagnosed with nonspecific LBP (nLBP). The slope of sacroiliac bone marrow HU (Hounsfield unit) curve (λHU), CT value, and bone marrow to normal muscle ratios of water and calcium concentrations in the ilium and sacrum were calculated and compared between nLBP and SpA patients. The iliac λHU was 8.26 ± 3.91 for nLBP and 9.81 ± 4.92 for SpA. The mean iliac ratios of water and calcium concentrations were 1.04 ± 0.03 and 21.67 ± 4.40, respectively, for nLBP, and 1.07 ± 0.04 and 111.5 ± 358.98, respectively, for SpA. The mean iliac CT values were 311.12 ± 86.52 HU for nLBP and 423.97 ± 127.51 HU for SpA. There were statistically significant differences in iliac ratios of water and calcium concentrations, CT value, and λHU between nLBP and SpA patients (p sacroiliac joints of SpA patients. Copyright © 2015. Published by Elsevier B.V.

  5. Proteomics: a tool to develop novel diagnostic methods and unravel molecular mechanisms of pediatric diseases.

    Science.gov (United States)

    Torres-Arroyo, Angélica; Ruiz-Lara, Arturo; Castillo-Villanueva, Adriana; Méndez-Cruz, Sara Teresa; Espinosa-Padilla, Sara Elvia; Espinosa-Rosales, Francisco Javier; Zarate-Mondragón, Flora; Cervantes-Bustamante, Roberto; Bosch-Canto, Vanessa; Vizzuett-López, Iris; Ordaz-Fávila, Juan Carlos; Oria-Hernández, Jesús; Reyes-Vivas, Horacio

    Proteomics is the study of the expression of changes and post-translational modifications (PTM) of proteins along a metabolic condition either normal or pathological. In the field of health, proteomics allows obtaining valuable data for treatment, diagnosis or pathophysiological mechanisms of different illnesses. To illustrate the aforementioned, we describe two projects currently being performed at the Instituto Nacional de Pediatría: The immuno-proteomic study of cow milk allergy and the Proteomic study of childhood cataract. Cow's milk proteins (CMP) are the first antigens to which infants are exposed and generate allergy in some of them. In Mexico, the incidence of CMP allergy has been estimated at 5-7%. Clinical manifestations include both gastrointestinal and extra-gastrointestinal symptoms, making its diagnosis extremely difficult. An inappropriate diagnosis affects the development and growth of children. The goals of the study are to identify the main immune-reactive CMP in Mexican pediatric population and to design more accurate diagnostic tools for this disease. Childhood cataract is a major ocular disease representing one of the main causes of blindness in infants; in developing countries, this disease promotes up to 27% of cases related to visual loss. From this group, it has been estimated that close to 60% of children do not survive beyond two years after vision lost. PTM have been pointed out as the main cause of protein precipitation at the crystalline and, consequently, clouding of this tissue. The study of childhood cataract represents an outstanding opportunity to identify the PTM associated to the cataract-genesis process. Copyright © 2017 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  6. METHOD OF NON-CONTACT PHOTOLUMINESCENT DIAGNOSTICS OF THE EYE FIBROUS TUNIC CONDITION

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2018-01-01

    Full Text Available Non-contact optical diagnostics of structural disorders of the eye has a number of advantages: high speed, accuracy and a large range of parameters available for analysis. The paper presents the results of studies of the photoluminescence of the fibrous tunic of the eye, excited by polarized light, depending on the intraocular pressure. In the experiments, isolated de-epithelized eyes of the rabbit were used, inside of which pressure up to 50 mm Hg was artificially created. Under these conditions, the cornea and sclera were illuminated with linearly polarized light at wavelengths of 250, 350 and 450 nm, exciting photoluminescence in the wavelength range up to 700 nm. Cross and co-polarized photoluminescence spectra excited by linearly polarized light were obtained. It has been established that, when excited by polarized light, the photoluminescence of the cornea is partially polarized. Depending on the wavelength of the photoluminescence, the degree of polarization varies from 0.2 to 0.35. It is shown that the degree of polarization of the photoluminescence of the cornea of the eye upon excitation by linearly polarized light can be used as a measurable parameter for assessing the physiological state of the eye. It is shown that the photoluminescence spectrum consists of two bands with maxima near 460-470 and 430-440 nm. These bands are assigned, respectively, to pyridinnucleotides and glycosylated collagen. A significant contribution can be made by the epithelium of the eye, which contains riboflavin with characteristic absorption bands near 450 and 365 nm. When excited at 450 nm, the photoluminescence maximum is located near 540 nm, which corresponds to the spectrum of fluorophores in the endothelium and epithelium. The spectrum of photoluminescence upon excitation at a wavelength of 250 nm can be attributed to tryptophan located in the intraocular lens.

  7. Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†.

    Science.gov (United States)

    Schiffman, Eric; Ohrbach, Richard; Truelove, Edmond; Look, John; Anderson, Gary; Goulet, Jean-Paul; List, Thomas; Svensson, Peter; Gonzalez, Yoly; Lobbezoo, Frank; Michelotti, Ambra; Brooks, Sharon L; Ceusters, Werner; Drangsholt, Mark; Ettlin, Dominik; Gaul, Charly; Goldberg, Louis J; Haythornthwaite, Jennifer A; Hollender, Lars; Jensen, Rigmor; John, Mike T; De Laat, Antoon; de Leeuw, Reny; Maixner, William; van der Meulen, Marylee; Murray, Greg M; Nixdorf, Donald R; Palla, Sandro; Petersson, Arne; Pionchon, Paul; Smith, Barry; Visscher, Corine M; Zakrzewska, Joanna; Dworkin, Samuel F

    2014-01-01

    The original Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms have been demonstrated to be reliable. However, the Validation Project determined that the RDC/TMD Axis I validity was below the target sensitivity of ≥ 0.70 and specificity of ≥ 0.95. Consequently, these empirical results supported the development of revised RDC/TMD Axis I diagnostic algorithms that were subsequently demonstrated to be valid for the most common pain-related TMD and for one temporomandibular joint (TMJ) intra-articular disorder. The original RDC/TMD Axis II instruments were shown to be both reliable and valid. Working from these findings and revisions, two international consensus workshops were convened, from which recommendations were obtained for the finalization of new Axis I diagnostic algorithms and new Axis II instruments. Through a series of workshops and symposia, a panel of clinical and basic science pain experts modified the revised RDC/TMD Axis I algorithms by using comprehensive searches of published TMD diagnostic literature followed by review and consensus via a formal structured process. The panel's recommendations for further revision of the Axis I diagnostic algorithms were assessed for validity by using the Validation Project's data set, and for reliability by using newly collected data from the ongoing TMJ Impact Project-the follow-up study to the Validation Project. New Axis II instruments were identified through a comprehensive search of the literature providing valid instruments that, relative to the RDC/TMD, are shorter in length, are available in the public domain, and currently are being used in medical settings. The newly recommended Diagnostic Criteria for TMD (DC/TMD) Axis I protocol includes both a valid screener for detecting any pain-related TMD as well as valid diagnostic criteria for differentiating the most common pain-related TMD (sensitivity ≥ 0.86, specificity ≥ 0.98) and for one intra

  8. ICALEO '89 - Optical methods in flow and particle diagnostics; Proceedings of the Meeting, Orlando, FL, Oct. 15-20, 1989

    Science.gov (United States)

    Long, Marshall B.

    Various papers on optical methods in flow and particle diagnostics are presented. Individual topics addressed include: swirl effects on confined flows in a model of a dump combustor, new analog optical method for data evaluation in laser Doppler anemometry, catadioptric optics for laser Doppler velocimeter applications, mapping of velocity flow field using the laser two-focus technique, engineering applications of particle image velocimeters, quantitative fluid flow analysis by laser velocimetry and numerical processing, optical analysis of particle image velocimetry data. Also discussed are: measuring turbulence in reversing flows by particle image velocimeter, two-color particle velocimetry, data evaluation in particle image velocimetry using spatial light modulator, statistical investigation of errors in particle image velocimetry, optimization of particle image velocimeters, visualization of internal structure in volumetric data, scalar measurements in two, three, and four dimensions.

  9. Molecular methods for pathogen and microbial community detection and characterization: current and potential application in diagnostic microbiology.

    Science.gov (United States)

    Sibley, Christopher D; Peirano, Gisele; Church, Deirdre L

    2012-04-01

    Clinical microbiology laboratories worldwide have historically relied on phenotypic methods (i.e., culture and biochemical tests) for detection, identification and characterization of virulence traits (e.g., antibiotic resistance genes, toxins) of human pathogens. However, limitations to implementation of molecular methods for human infectious diseases testing are being rapidly overcome allowing for the clinical evaluation and implementation of diverse technologies with expanding diagnostic capabilities. The advantages and limitation of molecular techniques including real-time polymerase chain reaction, partial or whole genome sequencing, molecular typing, microarrays, broad-range PCR and multiplexing will be discussed. Finally, terminal restriction fragment length polymorphism (T-RFLP) and deep sequencing are introduced as technologies at the clinical interface with the potential to dramatically enhance our ability to diagnose infectious diseases and better define the epidemiology and microbial ecology of a wide range of complex infections. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Satisfaction rates with the current Special Type Consultation (STC) reimbursement scheme among General Practitioners – A Mixed Methods Study.

    LENUS (Irish Health Repository)

    Kiely, A

    2017-03-01

    The Special Type Consultation (STC) scheme is a fee-for-service reimbursement scheme for General Practitioners (GPs) in Ireland. Introduced in 1989, the scheme includes specified patient services involving the application of a learned skill, e.g. suturing. This study aims to establish the extent to which GPs believe this scheme is appropriate for current General Practice. This is an embedded mixed-methods study combining quantitative data on GPs working experience of and qualitative data on GPs attitudes towards the scheme. Data were collected by means of an anonymous postal questionnaire. The response rate was 60.4% (n=159.) Twenty-nine percent (n=46) disagreed and 65% (n=104) strongly disagreed that the current list of special items is satisfactory. Two overriding themes were identified: economics and advancement of the STC process. This study demonstrates an overwhelming consensus among GPs that the current STC scheme is outdated and in urgent need of revision to reflect modern General Practice.

  11. The clinical significance of computerized axial tomography (CAT) in consideration of conventional diagnostic methods

    International Nuclear Information System (INIS)

    Huenig, R.

    1976-01-01

    Regarding CAT of the intracranial region, the article informs on a) techniques of examination including the production of normal structures, b) the recognizable pathological changes, c) possibilities of enhancement, d) possibilities of course observation, e) limitations of the methods, as well as on f) risk/benefit aspects g) benefit/cost calculations as compared to conventional methods, and on h) the influence of CAT on the frequency of conventional methods of examination. Regarding CAT of the extracranial region, the information available up to the meeting is reported on. (orig./LH) [de

  12. The role of radionuclide methods in diagnostics of esophagus diseases. Part I

    International Nuclear Information System (INIS)

    Golebiewska, R.; Chrapko, B. E.; Stefaniak, B.; Tarkowska, A.

    2005-01-01

    Two methods of esophageal scintigraphy are presented in this article: esophageal transit imaging and gastro-esophageal reflux examination. The procedures used and the most important indications for both examinations are discussed. It is concluded, that the both methods deserve attention and a wider application in the clinical routine, despite some limitations, resulting from the lacking standardization. They are non-invasive, connected with low radiation exposure, well tolerated, quick and easy to perform, reliable, and yield quantitative results. The above advantages make the both methods useful, especially for diagnosing gastro-esophageal reflux in pediatric patients. (author)

  13. Depression and suicidal behavior in adolescents: a multi-informant and multi-methods approach to diagnostic classification.

    Directory of Open Access Journals (Sweden)

    Andrew James Lewis

    2014-07-01

    Full Text Available Background: Informant discrepancies have been reported between parent and adolescent measures of depressive disorders and suicidality. We aimed to examine the concordance between adolescent and parent ratings of depressive disorder using both clinical interview and questionnaire measures and assess multi-informant and multi-method approaches to classification.Method: Within the context of assessment of eligibility for a randomized clinical trial, 50 parent–adolescent pairs (mean age of adolescents = 15.0 years were interviewed separately with a structured diagnostic interview for depression, the KID-SCID. Adolescent self-report and parent-report versions of the Strengths and Difficulties Questionnaire, the Short Mood and Feelings Questionnaire and the Depressive Experiences Questionnaire were also administered. We examined the diagnostic concordance rates of the parent vs. adolescent structured interview methods and the prediction of adolescent diagnosis via questionnaire methods.Results: Parent proxy reporting of adolescent depression and suicidal thoughts and behavior is not strongly concordant with adolescent report. Adolescent self-reported symptoms on depression scales provide a more accurate report of diagnosable adolescent depression than parent proxy reports of adolescent depressive symptoms. Adolescent self-report measures can be combined to improve the accuracy of classification. Parents tend to over report their adolescent’s depressive symptoms while under reporting their suicidal thoughts and behavior.Conclusion: Parent proxy report is clearly less reliable than the adolescent’s own report of their symptoms and subjective experiences, and could be considered inaccurate for research purposes. While parent report would still be sought clinically where an adolescent refuses to provide information, our findings suggest that parent reporting of adolescent suicidality should be interpreted with caution.

  14. Development of an automated method for in situ measurement of the geometrical properties of the ITER bolometer diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Meister, H., E-mail: meister@ipp.mpg.de; Penzel, F.; Giannone, L.; Kannamueller, M.; Kling, A.; Koll, J.; Trautmann, T.

    2011-10-15

    In order to derive the local emission profile of the plasma radiation in a fusion device using the line-integrated measurements of the bolometer diagnostic, tomographic reconstruction methods have to be applied to the measurements from many lines-of-sight. A successful reconstruction needs to take the finite sizes of detectors and apertures and the resulting non-ideal measurements into account. In ITER a method for in situ measurement of the geometrical properties of the various components of the bolometer diagnostic after installation is required as the viewing cones have to pass through narrow gaps between components. The method proposed to be used for ITER uses the beam of a laser with high intensity to illuminate the bolometer assembly from many different angles {xi} and {theta}. A light-weight robot from Kuka Robotics is used to efficiently position the laser on many points covering the complete viewing cone of each line-of-sight and to direct the beam precisely into the entrance aperture of the bolometer. Measuring the response of the bolometer allows for the calculation of the transmission function t({xi}, {theta}), the angular etendue and finally the geometric function in reconstruction space, which is required for the tomography algorithms. Measuring the transmission function for a laboratory assembly demonstrates the viability of the proposed method. Results for a collimator-type camera from a prototype envisaged for ITER are presented. The implemented procedure is discussed in detail, in particular with respect to the automatisation applied which takes the achievable positioning and alignment accuracies of the robot into account. This discussion is extended towards the definition of requirements for a remote-handling tool for ITER.

  15. Technetium 99-m labeled radio-diagnostic agents employing stannous tartrate and method of preparation

    International Nuclear Information System (INIS)

    Molinski, V.J.; Wilczewski, J.A.

    1976-01-01

    A method of preparing improved technetium-99m labeled radiodiagnostic agents by reducing technetium-99m with stannous tartrate. Such radiodiagnostic agents are useful in scintigraphic examinations of the bone and lung. 31 claims, no drawings

  16. Evaluation of the Ortho-Clinical Diagnostics Vitros ECi Anti-HCV test: comparison with three other methods.

    Science.gov (United States)

    Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C

    2007-01-01

    After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.

  17. Diagnostic Criteria for Problematic Internet Use among U.S. University Students: A Mixed-Methods Evaluation

    Science.gov (United States)

    Li, Wen; O’Brien, Jennifer E.; Snyder, Susan M.; Howard, Matthew O.

    2016-01-01

    Empirical studies have identified increasing rates of problematic Internet use worldwide and a host of related negative consequences. However, researchers disagree as to whether problematic Internet use is a subtype of behavioral addiction. Thus, there are not yet widely accepted and validated diagnostic criteria for problematic Internet use. To address this gap, we used mixed-methods to examine the extent to which signs and symptoms of problematic Internet use mirror DSM-5 diagnostic criteria for substance use disorder, gambling disorder, and Internet gaming disorder. A total of 27 university students, who self-identified as intensive Internet users and who reported Internet-use-associated health and/or psychosocial problems were recruited. Students completed two measures that assess problematic Internet use (Young’s Diagnostic Questionnaire and the Compulsive Internet Use Scale) and participated in focus groups exploring their experiences with problematic Internet use. Results of standardized measures and focus group discussions indicated substantial overlap between students’ experiences of problematic Internet use and the signs and symptoms reflected in the DSM-5 criteria for substance use disorder, gambling disorder, and Internet gaming disorder. These signs and symptoms included: a) use Internet longer than intended, b) preoccupation with the Internet, c) withdrawal symptoms when unable to access the Internet, d) unsuccessful attempts to stop or reduce Internet use, e) craving, f) loss of interest in hobbies or activities other than the Internet, g) excessive Internet use despite the knowledge of related problems, g) use of the Internet to escape or relieve a negative mood, and h) lying about Internet use. Tolerance, withdrawal symptoms, and recurrent Internet use in hazardous situations were uniquely manifested in the context of problematic Internet use. Implications for research and practice are discussed. PMID:26751569

  18. Diagnostic Criteria for Problematic Internet Use among U.S. University Students: A Mixed-Methods Evaluation.

    Directory of Open Access Journals (Sweden)

    Wen Li

    Full Text Available Empirical studies have identified increasing rates of problematic Internet use worldwide and a host of related negative consequences. However, researchers disagree as to whether problematic Internet use is a subtype of behavioral addiction. Thus, there are not yet widely accepted and validated diagnostic criteria for problematic Internet use. To address this gap, we used mixed-methods to examine the extent to which signs and symptoms of problematic Internet use mirror DSM-5 diagnostic criteria for substance use disorder, gambling disorder, and Internet gaming disorder. A total of 27 university students, who self-identified as intensive Internet users and who reported Internet-use-associated health and/or psychosocial problems were recruited. Students completed two measures that assess problematic Internet use (Young's Diagnostic Questionnaire and the Compulsive Internet Use Scale and participated in focus groups exploring their experiences with problematic Internet use. Results of standardized measures and focus group discussions indicated substantial overlap between students' experiences of problematic Internet use and the signs and symptoms reflected in the DSM-5 criteria for substance use disorder, gambling disorder, and Internet gaming disorder. These signs and symptoms included: a use Internet longer than intended, b preoccupation with the Internet, c withdrawal symptoms when unable to access the Internet, d unsuccessful attempts to stop or reduce Internet use, e craving, f loss of interest in hobbies or activities other than the Internet, g excessive Internet use despite the knowledge of related problems, g use of the Internet to escape or relieve a negative mood, and h lying about Internet use. Tolerance, withdrawal symptoms, and recurrent Internet use in hazardous situations were uniquely manifested in the context of problematic Internet use. Implications for research and practice are discussed.

  19. Methods Developed by the Tools for Engine Diagnostics Task to Monitor and Predict Rotor Damage in Real Time

    Science.gov (United States)

    Baaklini, George Y.; Smith, Kevin; Raulerson, David; Gyekenyesi, Andrew L.; Sawicki, Jerzy T.; Brasche, Lisa

    2003-01-01

    Tools for Engine Diagnostics is a major task in the Propulsion System Health Management area of the Single Aircraft Accident Prevention project under NASA s Aviation Safety Program. The major goal of the Aviation Safety Program is to reduce fatal aircraft accidents by 80 percent within 10 years and by 90 percent within 25 years. The goal of the Propulsion System Health Management area is to eliminate propulsion system malfunctions as a primary or contributing factor to the cause of aircraft accidents. The purpose of Tools for Engine Diagnostics, a 2-yr-old task, is to establish and improve tools for engine diagnostics and prognostics that measure the deformation and damage of rotating engine components at the ground level and that perform intermittent or continuous monitoring on the engine wing. In this work, nondestructive-evaluation- (NDE-) based technology is combined with model-dependent disk spin experimental simulation systems, like finite element modeling (FEM) and modal norms, to monitor and predict rotor damage in real time. Fracture mechanics time-dependent fatigue crack growth and damage-mechanics-based life estimation are being developed, and their potential use investigated. In addition, wireless eddy current and advanced acoustics are being developed for on-wing and just-in-time NDE engine inspection to provide deeper access and higher sensitivity to extend on-wing capabilities and improve inspection readiness. In the long run, these methods could establish a base for prognostic sensing while an engine is running, without any overt actions, like inspections. This damage-detection strategy includes experimentally acquired vibration-, eddy-current- and capacitance-based displacement measurements and analytically computed FEM-, modal norms-, and conventional rotordynamics-based models of well-defined damages and critical mass imbalances in rotating disks and rotors.

  20. Comparison of sample types and diagnostic methods for in vivo detection of Mycoplasma hyopneumoniae during early stages of infection.

    Science.gov (United States)

    Pieters, Maria; Daniels, Jason; Rovira, Albert

    2017-05-01

    Detection of Mycoplasma hyopneumoniae in live pigs during the early stages of infection is critical for timely implementation of control measures, but is technically challenging. This study compared the sensitivity of various sample types and diagnostic methods for detection of M. hyopneumoniae during the first 28days after experimental exposure. Twenty-one 8-week old pigs were intra-tracheally inoculated on day 0 with M. hyopneumoniae strain 232. Two age matched pigs were mock inoculated and maintained as negative controls. On post-inoculation days 0, 2, 5, 9, 14, 21 and 28, nasal swabs, laryngeal swabs, tracheobronchial lavage fluid, and blood samples were obtained from each pig and oral fluid samples were obtained from each room in which pigs were housed. Serum samples were assayed by ELISA for IgM and IgG M. hyopneumoniae antibodies and C-reactive protein. All other samples were tested for M. hyopneumoniae DNA by species-specific real-time PCR. Serum antibodies (IgG) to M. hyopneumoniae were detected in challenge-inoculated pigs on days 21 and 28. M. hyopneumoniae DNA was detected in samples from experimentally inoculated pigs beginning at 5days post-inoculation. Laryngeal swabs at all samplings beginning on day 5 showed the highest sensitivity for M. hyopneumoniae DNA Detection, while oral fluids showed the lowest sensitivity. Although laryngeal swabs are not considered the typical M. hyopneumoniae diagnostic sample, under the conditions of this study laryngeal swabs tested by PCR proved to be a practical and reliable diagnostic sample for M. hyopneumoniae detection in vivo during early-stage infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The use of digital PCR to improve the application of quantitative molecular diagnostic methods for tuberculosis.

    Science.gov (United States)

    Devonshire, Alison S; O'Sullivan, Denise M; Honeyborne, Isobella; Jones, Gerwyn; Karczmarczyk, Maria; Pavšič, Jernej; Gutteridge, Alice; Milavec, Mojca; Mendoza, Pablo; Schimmel, Heinz; Van Heuverswyn, Fran; Gorton, Rebecca; Cirillo, Daniela Maria; Borroni, Emanuele; Harris, Kathryn; Barnard, Marinus; Heydenrych, Anthenette; Ndusilo, Norah; Wallis, Carole L; Pillay, Keshree; Barry, Thomas; Reddington, Kate; Richter, Elvira; Mozioğlu, Erkan; Akyürek, Sema; Yalçınkaya, Burhanettin; Akgoz, Muslum; Žel, Jana; Foy, Carole A; McHugh, Timothy D; Huggett, Jim F

    2016-08-03

    Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification

  2. Special Semester titled Geometric mechanics : variational and stochastic methods : CIB, Lausanne, Switzerland, January-June 2015

    CERN Document Server

    Cruzeiro, Ana; Holm, Darryl

    2017-01-01

    Collecting together contributed lectures and mini-courses, this book details the research presented in a special semester titled “Geometric mechanics – variational and stochastic methods” run in the first half of 2015 at the Centre Interfacultaire Bernoulli (CIB) of the Ecole Polytechnique Fédérale de Lausanne. The aim of the semester was to develop a common language needed to handle the wide variety of problems and phenomena occurring in stochastic geometric mechanics. It gathered mathematicians and scientists from several different areas of mathematics (from analysis, probability, numerical analysis and statistics, to algebra, geometry, topology, representation theory, and dynamical systems theory) and also areas of mathematical physics, control theory, robotics, and the life sciences, with the aim of developing the new research area in a concentrated joint effort, both from the theoretical and applied points of view. The lectures were given by leading specialists in different areas of mathematics a...

  3. Method of development force at the young gymnasts on the stages of initial and specialized preparation

    Directory of Open Access Journals (Sweden)

    Khudolii O.N.

    2010-08-01

    Full Text Available The terms of effective development of force are considered for young gymnasts on the stages of initial and specialized preparation. The models of urgent and moved aside training effect of the power loadings are certain for young gymnasts 7-13 years. It is set that the process of power preparation of young gymnasts can be separate on two stages. On the first stage by means of the concentrated power loadings the expressed decline of force of group of muscles is arrived at. On the second stage by means of favourable a display maximal efforts of loadings the increase of force of group of muscles is arrived at. Application of the power loadings of different orientation is given by possibility during 10-12 employments on 30-60% to increase force of group of muscles, shorten time of training on development of force in two times.

  4. Changes in the diagnostic and therapeutic methods for Lemmel′s syndrome over the past 20 years in China

    Directory of Open Access Journals (Sweden)

    ZHU Fengshang

    2018-03-01

    Full Text Available ObjectiveTo investigate the changes in the diagnostic and therapeutic methods for Lemmel′s syndrome over the past 20 years in China, and to provide experience for standardized diagnosis and treatment of this disease. MethodsA retrospective analysis was performed for the clinical data of 23 patients with Lemmel′s syndrome who were diagnosed and treated in Tongji Hospital of Tongji University from January 1998 to June 2017 and 384 patients with Lemmel′s syndrome reported in China during the same period of time (407 patients in total. According to the admission time, the patients were divided into groups A (139 patients admitted from 1998 to 2007 and B (268 patients admitted from 2008 to 2017. The patients′ clinical features, diagnostic and therapeutic methods, and prognosis were recorded. The t-test was used for comparison of normally distributed continuous data between groups, and the Wilcoxon rank sum test was used for comparison of non-normally distributed continuous data between groups, the chi-square test was used for comparison of categorical data between groups. ResultsCompared with group A, group B had significantly higher age of onset (67.8±17.8 vs 62.3±12.3, t=-13.238, P= 0.019 and incidence rate of cholangitis (45.9% vs 32.4%, χ2=6.903, P=0.009. As for diagnostic methods, compared with group A, group B had a significantly higher proportion of patients who used multi-slice spiral CT (MSCT (26.9% vs 8.6%, χ2=18.576, P<0.001, endoscopic ultrasonography (EUS (15.7% vs 5.8%, χ2=8.352, P=0.004, magnetic resonance cholangiopancreatography (MRCP (75.0% vs 33.1%, χ2=67.303, P<0.001, or endoscopic retrograde cholangiopancreatography (ERCP (63.4% vs 36.7%, χ2=26377, P<0.001, while the two groups had a similar false positive rate (22.8% vs 28.1%, χ2=1.385, P=0.239. As for therapeutic methods, compared with group A, group B had a significantly higher proportion of patients who underwent ERCP combined with conservative

  5. DIAGNOSTIC EVALUATION OF NUMBERICAL AIR QUALITY MODELS WITH SPECIALIZED AMBIENT OBSERVATIONS: TESTING THE COMMUNITY MULTISCALE AIR QUALITY MODELING SYSTEM (CMAQ) AT SELECTED SOS 95 GROUND SITES

    Science.gov (United States)

    Three probes for diagnosing photochemical dynamics are presented and applied to specialized ambient surface-level observations and to a numerical photochemical model to better understand rates of production and other process information in the atmosphere and in the model. Howeve...

  6. Development of diagnostic RI test method for antiglutamic acid decarboxylase (GAD) in SMS and IDDM patients

    International Nuclear Information System (INIS)

    Ota, Mitsuhiro; Ota, Kiyoe; Nishimura, Masataka; Ma Jie; Obayashi, Hiroshi; Saida, Takahiko

    2000-01-01

    Western blotting with antigens purified using its specific antibody bound column has demonstrated that patients with Stiff-man syndrome (SMS) and insulin-dependent diabetic mellitus (IDDM) were both positive for anti-GAD antibody. Further, anti-GAD antibodies from various animal brains were characterized using GAD 65 and GAD 67 peptide antibody. The antibody against the anti-N-terminal peptide inhibited the enzyme activity of GAD, suggesting that the active site of GAD might exist in the N-terminal region. Development of a new detection method for anti-GAD antibody was attempted and the amount of GAD protein bound to protein G resin was determined based on the activity to release 14 CO 2 from 14 C glutamic acid. In addition, solid-phase RIA method was developed using GAD purified by the anti-peptide antibody affinity column. The positive detection rate for GAD antibody was 39% for the enzymatic method and 56% for the solid-phase RIA method. To develop a further sensitive detection method for GAD antibody, construction of recombinant GAD was attempted and two GAD65s different in molecular size were constructed using pMal-c vector. Thus obtained antibodies against anti-N-terminal peptides were separately responded to GAD65 and GAD67 isoforms in the rat, mouse and bovine brains, whereas the carboxy-terminal antibodies were reactive to both isoforms together. Therefore, it became possible to make purification of GAD65 and GAD67 by the use of the two N-terminal peptide antibodies. Further, it became possible to purify GAD as a mixture of both isoforms. However, the yield of purification using anti-affinity column was still unsatisfactory ( several percent) and the GAD preparation obtained had little activity. The positive detection by the solid-phase RIA method was 50% for SMS patients and 56% for IDDM ones, indicating that this method was superior to the previous enzyme method. The protein A method in which labeled human recombinant GAD65 was used to precipitate 125 -I

  7. Development of diagnostic RI test method for antiglutamic acid decarboxylase (GAD) in SMS and IDDM patients

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Mitsuhiro; Ota, Kiyoe; Nishimura, Masataka; Ma Jie; Obayashi, Hiroshi; Saida, Takahiko [Utano National Hospital, Kyoto (Japan)

    2000-02-01

    Western blotting with antigens purified using its specific antibody bound column has demonstrated that patients with Stiff-man syndrome (SMS) and insulin-dependent diabetic mellitus (IDDM) were both positive for anti-GAD antibody. Further, anti-GAD antibodies from various animal brains were characterized using GAD 65 and GAD 67 peptide antibody. The antibody against the anti-N-terminal peptide inhibited the enzyme activity of GAD, suggesting that the active site of GAD might exist in the N-terminal region. Development of a new detection method for anti-GAD antibody was attempted and the amount of GAD protein bound to protein G resin was determined based on the activity to release {sup 14}CO{sub 2} from {sup 14}C glutamic acid. In addition, solid-phase RIA method was developed using GAD purified by the anti-peptide antibody affinity column. The positive detection rate for GAD antibody was 39% for the enzymatic method and 56% for the solid-phase RIA method. To develop a further sensitive detection method for GAD antibody, construction of recombinant GAD was attempted and two GAD65s different in molecular size were constructed using pMal-c vector. Thus obtained antibodies against anti-N-terminal peptides were separately responded to GAD65 and GAD67 isoforms in the rat, mouse and bovine brains, whereas the carboxy-terminal antibodies were reactive to both isoforms together. Therefore, it became possible to make purification of GAD65 and GAD67 by the use of the two N-terminal peptide antibodies. Further, it became possible to purify GAD as a mixture of both isoforms. However, the yield of purification using anti-affinity column was still unsatisfactory ( several percent) and the GAD preparation obtained had little activity. The positive detection by the solid-phase RIA method was 50% for SMS patients and 56% for IDDM ones, indicating that this method was superior to the previous enzyme method. The protein A method in which labeled human recombinant GAD65 was used to

  8. Research program in reactor core diagnostics with neutron noise methods: Stage 3. Final report

    International Nuclear Information System (INIS)

    Pazsit, I.; Garis, N.S.; Karlsson, J.; Racz, A.

    1997-09-01

    Stage 3 of the program has been executed 96-04-12. The long term goal is to develop noise methods for identification and localization of perturbations in reactor cores. The main parts of the program consist of modelling the noise source, calculation of the space- and frequency dependent transfer function, calculation of the neutron noise via a convolution of the transfer function of the system and the noise source, i.e. the perturbation, and finally finding an inversion or unfolding procedure to determine noise source parameters from the neutron noise. Most previous work is based on very simple (analytical) reactor models for the calculation of the transfer function as well as analytical unfolding methods. The purpose of this project is to calculate the transfer function in a more realistic model as well as elaborating powerful inversion methods that do not require analytical transfer functions. The work in stage 3 is described under the following headlines: Further investigation of simplified models for the calculation of the neutron noise; Further investigation of methods based on neural networks; Further investigation of methods for detecting the vibrations and impacting of detectors; Application of static codes for determination of the neutron noise using the adiabatic approximation

  9. A rapid method for myoglobin radioimmunoanalysis as a diagnostic tool in myocardial infarction

    International Nuclear Information System (INIS)

    Grachev, M.A.; Matveev, L.E.; Pressman, E.K.; Roschke, V.V.

    1982-01-01

    Stone et al. have elaborated a RIA-method for the determination of myoglobin, and found that increase of its concentration in serum is a reliable criterion for the diagnosis of myocardial infarction. However, the test took 24-28 h. Subsequently, the time of the analysis has been reduced to 5-6 h. Recently, a rapid method for the determination of myoglobin has been proposed based upon the use of antiserum immobilized on a powdered carrier. This method takes a little more than 1 h. The procedure according to Roxin et al. is fast due to its non-equilibrium character; after the incubation (30 min) the reaction of the antigen with the immobilized antibody still remains far from equilibrium. It is generally believed that non-equilibrium RIA procedures are less convenient than equilibrium ones for practical clinical applications. According to the RIA procedure proposed here, the time saving compared with the established methods is achieved by using relatively-high concentrations of radioactive myoglobin of moderate specific radioactivity. Under these conditions, the kinetic plateau is reached in 15-20 min. Hence, the total time of the analysis to obtain a standard curve and results for five unknown sera is 55 min. Therefore, the method becomes more useful as a guide in the treatment of myocardial infarction. (Auth.)

  10. A REVIEW OF VIBRATION MACHINE DIAGNOSTICS BY USING ARTIFICIAL INTELLIGENCE METHODS

    Directory of Open Access Journals (Sweden)

    Grover Zurita

    2016-09-01

    Full Text Available In the industry, gears and rolling bearings failures are one of the foremost causes of breakdown in rotating machines, reducing availability time of the production and resulting in costly systems downtime. Therefore, there are growing demands for vibration condition based monitoring of gears and bearings, and any method in order to improve the effectiveness, reliability, and accuracy of the bearing faults diagnosis ought to be evaluated. In order to perform machine diagnosis efficiently, researchers have extensively investigated different advanced digital signal processing techniques and artificial intelligence methods to accurately extract fault characteristics from vibration signals. The main goal of this article is to present the state-of-the-art development in vibration analysis for machine diagnosis based on artificial intelligence methods.

  11. Spectral finite element method wave propagation, diagnostics and control in anisotropic and inhomogeneous structures

    CERN Document Server

    Gopalakrishnan, Srinivasan; Roy Mahapatra, Debiprosad

    2008-01-01

    The use of composites and Functionally Graded Materials (FGMs) in structural applications has increased. FGMs allow the user to design materials for a specified functionality and have many uses in structural engineering. However, the behaviour of these structures under high-impact loading is not well understood. This book is the first to apply the Spectral Finite Element Method (SFEM) to inhomogeneous and anisotropic structures in a unified and systematic manner. It focuses on some of the problems with this media which were previously thought unmanageable. Types of SFEM for regular and damaged 1-D and 2-D waveguides, solution techniques, methods of detecting the presence of damages and their locations, and methods for controlling the wave propagation responses are discussed. Tables, figures and graphs support the theory and case studies are included. This book is of value to senior undergraduates and postgraduates studying in this field, and researchers and practicing engineers in structural integrity.

  12. The evaluation of winter wheat roots and leaf sheath diseases diagnostic methods

    Directory of Open Access Journals (Sweden)

    Ewa Solarska

    2012-12-01

    Full Text Available The maltose and mineral media for isolation of Gaeumannomyces graminis from roots were assessed. The differences in numbers of obtained isolates were found depending on the medium used and sampling date. Easier identification of pathogen was possible employing maltose medium. The fungi from genus Fusarium occurring on winter wheat leaf sheaths were identified by mycological analysis and PCR, while the fungus Pseudocercosporella herpotrichoides was detected by PCR and ELISA methods. PCR and ELISA methods enabled to detect pathogens also in periods before the disease symptoms on plants occurred.

  13. Beam deviation method as a diagnostic tool for the plasma focus

    International Nuclear Information System (INIS)

    Schmidt, H.; Rueckle, B.

    1978-01-01

    The application of an optical method for density measurements in cylindrical plasmas is described. The angular deviation of a probing light beam sent through the plasma is proportional to the maximum of the density in the plasma column. The deviation does not depend on the plasma dimensions, however, it is influenced to a certain degree by the density profile. The method is successfully applied to the investigation of a dense plasma focus with a time resolution of 2 ns and a spatial resolution (in axial direction) of 2 mm. (orig.) [de

  14. Clinical and Demographic Stratification of Test Performance: A Pooled Analysis of Five Laboratory Diagnostic Methods for American Cutaneous Leishmaniasis

    Science.gov (United States)

    Boggild, Andrea K.; Ramos, Ana P.; Espinosa, Diego; Valencia, Braulio M.; Veland, Nicolas; Miranda-Verastegui, Cesar; Arevalo, Jorge; Low, Donald E.; Llanos-Cuentas, Alejandro

    2010-01-01

    We evaluated performance characteristics of five diagnostic methods for cutaneous leishmaniasis. Patients who came to the Leishmania Clinic of Hospital Nacional Cayetano Heredia in Lima, Peru, were enrolled in the study. Lesion smears, culture, microculture, polymerase chain reaction (PCR), and leishmanin skin test (LST) were performed. A total of 145 patients with 202 lesions were enrolled: 114 patients with 161 lesions fulfilled criteria for cutaneous leishmaniasis. Sensitivity and specificity were 57.8% (95% confidence interval [CI] = 50.2–65.4%) and 100.0% for culture, 78.3% (95% CI = 71.9–84.7%) and 100.0% for microculture, 71.4% (95% CI = 64.4–78.4%) and 100.0% for smears, 78.2% (95% CI = 70.6–85.8%) and 77.4% (95% CI = 62.7–92.1%) for LST, and 96.9% (95% CI = 94.2–99.6%) and 65.9% (95% CI = 51.4–80.4%) for PCR. PCR was more sensitive than the other assays (P < 0.001). Sensitivities of culture, smears, and LST varied by lesion duration and appearance. PCR offers performance advantages over other assays, irrespective of patient age, sex, lesion duration, or appearance. That clinical factors influence performance of non-molecular assays offers clinicians a patient-focused approach to diagnostic test selection. PMID:20682880

  15. Vibration and noise diagnostics of nuclear power plants Pt. 1

    International Nuclear Information System (INIS)

    Nagy, I.

    1991-01-01

    Development, tasks and methodology of vibration and noise testing of nuclear power plants are overviewed. Reactor noise diagnostics methods are presented and their utilization at various reactors is summarized. Acoustic testing of primary circuit is also considered. Special attention is paid to leak detection and loose parts monitoring by acoustical testing methods. (R.P.) 11 refs.; 18 figs.; 1 tab

  16. Assessment of diagnostic technology in health care: rationale, methods, problems, and directions

    National Research Council Canada - National Science Library

    Sox, Harold C

    1989-01-01

    ... Rationale, Methods, Problems, and Directions Harold Sox, Susan Stern, Douglas Owens, and Herbert L. Abrams Institute of Medicine NATIONAL ACADEMY PRESS WASHINGTON, D.C. 1989 Copyrightthe cannot be not from book, paper however, version for formatting, original authoritative the typesetting-specific the as from created publication files XML from...

  17. New analysis methods to push the boundaries of diagnostic techniques in the environmental sciences

    International Nuclear Information System (INIS)

    Lungaroni, M.; Peluso, E.; Gelfusa, M.; Malizia, A.; Talebzadeh, S.; Gaudio, P.; Murari, A.; Vega, J.

    2016-01-01

    In the last years, new and more sophisticated measurements have been at the basis of the major progress in various disciplines related to the environment, such as remote sensing and thermonuclear fusion. To maximize the effectiveness of the measurements, new data analysis techniques are required. First data processing tasks, such as filtering and fitting, are of primary importance, since they can have a strong influence on the rest of the analysis. Even if Support Vector Regression is a method devised and refined at the end of the 90s, a systematic comparison with more traditional non parametric regression methods has never been reported. In this paper, a series of systematic tests is described, which indicates how SVR is a very competitive method of non-parametric regression that can usefully complement and often outperform more consolidated approaches. The performance of Support Vector Regression as a method of filtering is investigated first, comparing it with the most popular alternative techniques. Then Support Vector Regression is applied to the problem of non-parametric regression to analyse Lidar surveys for the environments measurement of particulate matter due to wildfires. The proposed approach has given very positive results and provides new perspectives to the interpretation of the data.

  18. Implementation of different histochemical methods in diagnostics of brain Aspergillosis in turkey chicks

    Directory of Open Access Journals (Sweden)

    Kureljušić Branislav

    2011-01-01

    Full Text Available Aspergillosis is a frequent fungal disease in different species of birds and mammals caused by fungi of the genus Aspergillus. It is characterized by inflammatory changes primarily in the respiratory system, even though it sometimes takes on a generalized form when several organ systems are affected. Mucotic-granulomatous meningoencephalitis with a predominant localization in the cerebellum has been described in turkeys, ducks and geese. Within this paper, examinations have been performed on a flock of broiler turkeys aged 12 days who had sustained evident neurological disorders in the form of ataxy, torticollis, paresis, and paralysis of the hind extremities and wings. In three of the ten autopsied chicks the macroscopic findings indicated granulomatous encephalitis of the cerebellum. A white-coloured granuloma, around 3mm in diameter, was situated cranioventrally and was clearly visible on the sagital section of the cerebellum. Mucological examinations of the cerebellum lesion resulted in the isolation of the fungi Aspergillus fumigatus. Haematoxylin-eosin (HE, Grocott and PAS methods were used for the evaluation of histopathological changes and proving Aspergillus fumigatusa hyphae. The microscopic examination of brain tissue sections stained with the HE method revealed the existence of a granuloma with a centrally placed necrotic area. The necrotic area was infiltrated with heterophilic granulocytes and surrounded by macrophage, giant cells and lymphocytes. A connective tissue capsule was located on the periphery of the granuloma. The fungi hyphae, as integral parts of the granuloma, were difficult to observe, and in some samples stained using the HE method they could not be seen at all. On the other hand, sections stanied using the Grocott and PAS methods showed prominent septed and branched hyphae in different parts of the granuloma. With the objective of making an etiological diagnosis of mucotic diseases, it is necessary to apply several

  19. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods.

    Science.gov (United States)

    Barbosa, José Augusto A; Rodrigues, Alexandre B; Mota, Cleonice Carvalho C; Barbosa, Márcia M; Simões e Silva, Ana C

    2011-01-01

    Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.

  20. Diagnostics of Susabi-nori (Porphyra Yezoensis) by Laser-Induced Fluorescence Method

    Science.gov (United States)

    Okamoto, Tamotsu; Nakamura, Yuki; Takahashi, Kunio; Kaneko, Shohei; Shimada, Yuji

    Susabi-nori (Porphyra yezoensis) was diagnosed by means of laser-induced fluorescence (LIF) method. Fluorescence peaks located at approximately 580, 660, 685 and 720 nm were observed in the LIF spectra of Susabi-nori. In the spectrum of the sample infected with the red rot disease, the intensity of 580 nm peak was relatively high as compared with that of the control sample. On the other hand, the intensities of 580 nm and 660 nm peaks drastically decreased by the influence of the chytrid disease. Furthermore, the intensity of the 580 nm peak increased by dipping into fresh water. These results indicate that LIF spectra of Susabi-nori are affected by the diseases and the stress of fresh water and that the diseases and the stress of Susabi-nori can be diagnosed by the LIF method.

  1. An approach to build knowledge base for reactor accident diagnostic system using statistical method

    International Nuclear Information System (INIS)

    Kohsaka, Atsuo; Yokobayashi, Masao; Matsumoto, Kiyoshi; Fujii, Minoru

    1988-01-01

    In the development of a rule based expert system, one of key issues is how to build a knowledge base (KB). A systematic approach has been attempted for building an objective KB efficiently. The approach is based on the concept that a prototype KB should first be generated in a systematic way and then it is to be modified and/or improved by expert for practical use. The statistical method, Factor Analysis, was applied to build a prototype KB for the JAERI expert system DISKET using source information obtained from a PWR simulator. The prototype KB was obtained and the inference with this KB was performed against several types of transients. In each diagnosis, the transient type was well identified. From this study, it is concluded that the statistical method used is useful for building a prototype knowledge base. (author)

  2. DIAGNOSTIC CHARACTERISTICS OF THE COMPUTER TESTS FORMED BY METHOD OF RESTORED FRAGMENTS

    Directory of Open Access Journals (Sweden)

    Oleksandr O. Petkov

    2013-03-01

    Full Text Available Definition of validity and reliability of tests which are formed by a method of restored fragments is considered in the article. The structure of the controlled theoretical material of limit field of knowledge, language expressions that describe the subject of control, and reliability of test, is analyzed. The technique of definition of the most important components of reliability of the considered tests is given: reliability of quantitative determination of coefficient of assimilation and technological reliability. Results of the lead pedagogical experiments have proved, that tests of the given class allow to make the control of mastering of a theoretical material over a level of reproduction in any field of knowledge with high reliability. It is shown, that validity tests with restored fragments basically caused by a degree of structurization and methodical study of a controllable material and can achieve beforehand set parameters, down to a level of absolute validity.

  3. Gastroesophageal reflux - correlation between diagnostic methods; Refluxo gastroesofagico - correlacao entre metodos diagnosticos

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Maria das Gracas de Almeida; Penas, Maria Exposito; Fonseca, Lea Mirian Barbosa [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Dept. de Radiologia-Medicina Nuclear; Lemme, Eponina Maria O. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Medicina. Dept. de Clinia Medica-Gastroenterologia; Martinho, Maria Jose Ribeiro [Hospital Universitario Clementino Fraga Filho, Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear

    1999-02-01

    A group of 97 individuals with typical symptoms of gastroesophageal reflux disease (GERD) was submitted to gastroesophageal reflux scintigraphy (GES) and compared to the results obtained from endoscopy, histopathology and 24 hours pHmetry. Twenty-four healthy individuals were used as a control group and they have done only the GERS. The results obtained showed that: (a) the difference in the reflux index (RI) for the control group and the sick individuals was statistically significant (p < 0.0001); (b) the correlation between GERS and the other methods showed the following results: sensitivity, 84%; specificity, 95%; positive predictive value, 98%; negative predictive value, 67%; accuracy, 87%. We have concluded that the scintigraphic method should be used to confirm the diagnosis of GERD and also recommended as initial investiative procedure. (author)

  4. METHODS FOR LOCAL CHANGES IN THE PLASTIC DEFORMATION DIAGNOSTICS ON THE WORK FUNCTION

    Directory of Open Access Journals (Sweden)

    K. V. Panteleyev

    2015-01-01

    Full Text Available The paper describes the electronic work function measurements by the contact potential difference technique, and experimental demonstration of the possibility of these methods application for the stress-strain state of the surface layer of the metals and alloys. The techniques end examples of their application of localization of plastic deformation studies using the Kelvin probe are developed and present. The study topology of work function the deformed surface possible to determine the type of deformation and dynamics of

  5. DIAGNOSTIC CHARACTERISTICS OF THE COMPUTER TESTS FORMED BY METHOD OF RESTORED FRAGMENTS

    OpenAIRE

    Oleksandr O. Petkov

    2013-01-01

    Definition of validity and reliability of tests which are formed by a method of restored fragments is considered in the article. The structure of the controlled theoretical material of limit field of knowledge, language expressions that describe the subject of control, and reliability of test, is analyzed. The technique of definition of the most important components of reliability of the considered tests is given: reliability of quantitative determination of coefficient of assimilation and te...

  6. Development of a bead-based multiplex genotyping method for diagnostic characterization of HPV infection.

    Directory of Open Access Journals (Sweden)

    Mee Young Chung

    Full Text Available The accurate genotyping of human papillomavirus (HPV is clinically important because the oncogenic potential of HPV is dependent on specific genotypes. Here, we described the development of a bead-based multiplex HPV genotyping (MPG method which is able to detect 20 types of HPV (15 high-risk HPV types 16, 18, 31, 33, 35, 39, 45, 51, 52, 53, 56, 58, 59, 66, 68 and 5 low-risk HPV types 6, 11, 40, 55, 70 and evaluated its accuracy with sequencing. A total of 890 clinical samples were studied. Among these samples, 484 were HPV positive and 406 were HPV negative by consensus primer (PGMY09/11 directed PCR. The genotyping of 484 HPV positive samples was carried out by the bead-based MPG method. The accuracy was 93.5% (95% CI, 91.0-96.0, 80.1% (95% CI, 72.3-87.9 for single and multiple infections, respectively, while a complete type mismatch was observed only in one sample. The MPG method indiscriminately detected dysplasia of several cytological grades including 71.8% (95% CI, 61.5-82.3 of ASCUS (atypical squamous cells of undetermined significance and more specific for high grade lesions. For women with HSIL (high grade squamous intraepithelial lesion and SCC diagnosis, 32 women showed a PPV (positive predictive value of 77.3% (95% CI, 64.8-89.8. Among women >40 years of age, 22 women with histological cervical cancer lesions showed a PPV of 88% (95% CI, 75.3-100. Of the highest risk HPV types including HPV-16, 18 and 31 positive women of the same age groups, 34 women with histological cervical cancer lesions showed a PPV of 77.3% (95% CI, 65.0-89.6. Taken together, the bead-based MPG method could successfully detect high-grade lesions and high-risk HPV types with a high degree of accuracy in clinical samples.

  7. Method for improved selectivity in photo-activation and detection of molecular diagnostic agents

    Science.gov (United States)

    Wachter, Eric A.; Fisher, Walter G.; Dees, H. Craig

    1998-01-01

    A method for the imaging of a particular volume of plant or animal tissue, wherein the plant or animal tissue contains at least one photo-active molecular agent. The method includes the steps of treating the particular volume of the plant or animal tissue with light sufficient to promote a simultaneous two-photon excitation of the photo-active molecular agent contained in the particular volume of the plant or animal tissue, photo-activating at least one of the at least one photo-active molecular agent in the particular volume of the plant or animal tissue, thereby producing at least one photo-activated molecular agent, wherein the at least one photo-activated molecular agent emits energy, detecting the energy emitted by the at least one photo-activated molecular agent, and producing a detected energy signal which is characteristic of the particular volume of plant or animal tissue. The present invention is also a method for the imaging of a particular volume of material, wherein the material contains at least one photo-active molecular agent.

  8. PCR-RFLP diagnostic method for identifying Globodera species in Slovenia

    Directory of Open Access Journals (Sweden)

    Sasa ŠIRCA

    2011-01-01

    Full Text Available Species identification within the genus Globodera is based on the morphological and morphometrical characters of the cysts and second stage juveniles, and these are included in the majority of identification keys. Morphometrical methods are fast and can be applied to most of samples but they demand a trained and experienced specialist. Furthermore, some morphometrical characters may overlap between populations and beetwen species, leading to inaccurate identification. To confirm and complement the morphometrical identification of Globodera species molecular methods have been developed. Sequences of the internal transcribed spacer regions ITS1 and ITS2 of the rDNA gene cluster proved to be useful for identifying nematode species identification. A PCR-RFLP molecular method was used to identify Globodera rostochiensis, G. pallida, G. tabacum and G. achilleae. Globodera rostochiensis, G. pallida, G. tabacum and G. achilleae can be distinguished with PCR-RFLP analysis of the rDNA ITS fragment using five restriction enzymes. The RFLP patterns of G. rostochiensis, G. tabacum and G. achilleae were species-specific, while those of G. pallida varied. South American populations of G. pallida differed from other populations as their RFLP patterns were demonstrated to be distinct by in silico restriction of the ITS sequences deposited at NCBI.

  9. Methods for improved selectivity in photo-activation and detection of molecular diagnostic agents

    Science.gov (United States)

    Wachter, Eric A [Oak Ridge, TN; Fisher, Walter G [Knoxville, TN; Dees, H Craig [Knoxville, TN

    2008-03-18

    A method for the imaging of a particular volume of plant or animal tissue, wherein the plant or animal tissue contains at least one photo-active molecular agent. The method comprises the steps of treating the particular volume of the plant or animal tissue with light sufficient to promote a simultaneous two-photon excitation of the photo-active molecular agent contained in the particular volume of the plant or animal tissue, photo-activating at least one of the at least one photo-active molecular agent in the particular volume of the plant or animal tissue, thereby producing at least one photo-activated molecular agent, wherein the at least one photo-activated molecular agent emits energy, detecting the energy emitted by the at least one photo-activated molecular agent, and producing a detected energy signal which is characteristic of the particular volume of plant or animal tissue. The present invention also provides a method for the imaging of a particular volume of material, wherein the material contains at least one photo-active molecular agent.

  10. Mesenteric vascular occlusion: a new diagnostic method using a radiolabeled monoclonal antibody reactive with platelets

    International Nuclear Information System (INIS)

    Oster, Z.H.; Som, P.; Zamora, P.O.

    1989-01-01

    A new method for diagnosing mesenteric vaso-occlusive bowel disease with the use of radioimmunoscintigraphy was developed and tested in experimental models of arterial and venous disease, as well as in a model simulating bowel strangulation. The method involves the use of a monoclonal antibody fragment mixture that binds to platelets. The antibody was labeled with technetium-99m, and imaging was performed with a gamma camera in the planar and single photon emission computed tomography modes. This method allowed visualization of areas of ischemia of 1-6 hours duration in bowel loops in 19 dogs 90-180 minutes after injection of the radiolabeled antibody. No bowel radioactivity accumulation occurred in dogs that underwent the same surgical procedure but were given a nonspecific Tc-99m-labeled antibody or in normal dogs given the specific antibody. It appears that the radiolabeled antibody used, which has higher reactivity with human platelets than with dog platelets, will be a good agent for noninvasive diagnosis of mesenteric vaso-occlusive disease in humans. It may also play a role in the intraoperative determination of the extent and location of ischemic bowel segments

  11. Novel methods for the synthesis of magnetite nanoparticles with special morphologies and textured assemblages

    Energy Technology Data Exchange (ETDEWEB)

    Nyiro-Kosa, Ilona, E-mail: kosaili@gmail.com [University of Pannonia, Department of Material Engineering (Hungary); Recnik, Aleksander [Jozef Stefan Institute, Department for Nanostructured Materials (Slovenia); Posfai, Mihaly [University of Pannonia, Department of Earth and Environmental Sciences (Hungary)

    2012-10-15

    There is an increasing technological demand for magnetic nanocrystals with special morphologies and controlled sizes. Several approaches are used for the synthesis of magnetite crystals with irregular or octahedral shapes; however, the room-temperature synthesis of nanocrystals with specific morphologies is not yet established. Here, we describe the synthesis of magnetite crystals (100-300 nm) at a relatively low temperature ({approx}70 Degree-Sign C) from organic precursors, including Fe(II) oxalate or Fe(II) sulfate, and study the effects of ethylene glycol and tetraethylene glycol on the final physical and chemical properties of the crystals. The magnetite crystals formed from different precursor materials (sulfate or oxalate green rust) show specific morphological and textural features. We show that octahedral magnetite crystals can be produced from Fe(II) oxalate via a simple co-precipitation process. Using different kinds and amounts of polyols, various types of particle morphologies and nanocrystal textures can be produced, including hexagonal-shaped clusters of elongated crystals and porous and solid, large, rounded polycrystalline aggregates.

  12. Novel methods for the synthesis of magnetite nanoparticles with special morphologies and textured assemblages

    International Nuclear Information System (INIS)

    Nyirő-Kósa, Ilona; Rečnik, Aleksander; Pósfai, Mihály

    2012-01-01

    There is an increasing technological demand for magnetic nanocrystals with special morphologies and controlled sizes. Several approaches are used for the synthesis of magnetite crystals with irregular or octahedral shapes; however, the room-temperature synthesis of nanocrystals with specific morphologies is not yet established. Here, we describe the synthesis of magnetite crystals (100–300 nm) at a relatively low temperature (∼70 °C) from organic precursors, including Fe(II) oxalate or Fe(II) sulfate, and study the effects of ethylene glycol and tetraethylene glycol on the final physical and chemical properties of the crystals. The magnetite crystals formed from different precursor materials (sulfate or oxalate green rust) show specific morphological and textural features. We show that octahedral magnetite crystals can be produced from Fe(II) oxalate via a simple co-precipitation process. Using different kinds and amounts of polyols, various types of particle morphologies and nanocrystal textures can be produced, including hexagonal-shaped clusters of elongated crystals and porous and solid, large, rounded polycrystalline aggregates.

  13. Essential Mathematics for the Physical Sciences; Volume I: Homogeneous boundary value problems, Fourier methods, and special functions

    Science.gov (United States)

    Borden, Brett; Luscombe, James

    2017-10-01

    Physics is expressed in the language of mathematics; it is deeply ingrained in how physics is taught and how it's practiced. A study of the mathematics used in science is thus a sound intellectual investment for training as scientists and engineers. This first volume of two is centered on methods of solving partial differential equations and the special functions introduced. This text is based on a course offered at the Naval Postgraduate School (NPS) and while produced for NPS needs, it will serve other universities well.

  14. A Novel 3D Imaging Method for Airborne Downward-Looking Sparse Array SAR Based on Special Squint Model

    Directory of Open Access Journals (Sweden)

    Xiaozhen Ren

    2014-01-01

    Full Text Available Three-dimensional (3D imaging technology based on antenna array is one of the most important 3D synthetic aperture radar (SAR high resolution imaging modes. In this paper, a novel 3D imaging method is proposed for airborne down-looking sparse array SAR based on the imaging geometry and the characteristic of echo signal. The key point of the proposed algorithm is the introduction of a special squint model in cross track processing to obtain accurate focusing. In this special squint model, point targets with different cross track positions have different squint angles at the same range resolution cell, which is different from the conventional squint SAR. However, after theory analysis and formulation deduction, the imaging procedure can be processed with the uniform reference function, and the phase compensation factors and algorithm realization procedure are demonstrated in detail. As the method requires only Fourier transform and multiplications and thus avoids interpolations, it is computationally efficient. Simulations with point scatterers are used to validate the method.

  15. Semi-automated non-invasive diagnostics method for melanoma differentiation from nevi and pigmented basal cell carcinomas

    Science.gov (United States)

    Lihacova, I.; Bolocko, K.; Lihachev, A.

    2017-12-01

    The incidence of skin cancer is still increasing mostly in in industrialized countries with light- skinned people. Late tumour detection is the main reason of the high mortality associated with skin cancer. The accessibility of early diagnostics of skin cancer in Latvia is limited by several factors, such as high cost of dermatology services, long queues on state funded oncologist examinations, as well as inaccessibility of oncologists in the countryside regions - this is an actual clinical problem. The new strategies and guidelines for skin cancer early detection and post-surgical follow-up intend to realize the full body examination (FBE) by primary care physicians (general practitioners, interns) in combination with classical dermoscopy. To implement this approach, a semi- automated method was established. Developed software analyses the combination of 3 optical density images at 540 nm, 650 nm, and 950 nm from pigmented skin malformations and classifies them into three groups- nevi, pigmented basal cell carcinoma or melanoma.

  16. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stages 14 and 15

    Energy Technology Data Exchange (ETDEWEB)

    Pazsit, Imre; Wihlstrand, Gustav; Tambouratzis, Tatiana; Jonsson, Anders; Dahl, Berit (Chalmers Univ. of Technology, Dept. of Nuclear Engineering, SE-412 96 Goeteborg (Sweden))

    2009-12-15

    This report constitutes Stages 14 and 15 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. Stage 14 was a full one-year project, whereas Stage 15 consisted of a half-year project. The program executed in Stages 14 and 15 consists of the following three parts: - Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR) (Stages 14 and 15); - An overview and introduction to fuzzy logics (Stage 14), and an application to two-phase flow identification (Stage 15) - Preparations for and execution of an IAEA-ICTP workshop on Neutron fluctuations, reactor noise and their applications in nuclear reactors (Stage 14)

  17. Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stages 14 and 15

    International Nuclear Information System (INIS)

    Pazsit, Imre; Wihlstrand, Gustav; Tambouratzis, Tatiana; Jonsson, Anders; Dahl, Berit

    2009-12-01

    This report constitutes Stages 14 and 15 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. Stage 14 was a full one-year project, whereas Stage 15 consisted of a half-year project. The program executed in Stages 14 and 15 consists of the following three parts: - Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR) (Stages 14 and 15); - An overview and introduction to fuzzy logics (Stage 14), and an application to two-phase flow identification (Stage 15) - Preparations for and execution of an IAEA-ICTP workshop on Neutron fluctuations, reactor noise and their applications in nuclear reactors (Stage 14)

  18. Farm-level risk factors for Fasciola hepatica infection in Danish dairy cattle as evaluated by two diagnostic methods

    DEFF Research Database (Denmark)

    Takeuchi-Storm, Nao; Denwood, Matthew; Hansen, Tina Vicky Alstrup

    2017-01-01

    ) as a tool for diagnosis in Danish dairy cattle farms was assessed. This case-control study aimed to identify farm-level risk factors for fasciolosis in Danish dairy farms (> 50 animals slaughtered in 2013) using two diagnostic methods: recordings of liver condemnation at slaughter, and farm-level Fasciola...... on wet pastures, dry cows grazing on wet pastures, herd size, breed and concurrent beef cattle production were identified as risk factors associated with being classified as a case farm. With the categorised BTM ELISA result as the response variable, heifers grazing on wet pastures, dry cows grazing...... on wet pastures, and purchase of cows were identified as risk factors. Within the case and control groups, 74.8 and 12.7% of farms were positive for fasciolosis on BTM ELISA, respectively. The differences are likely to be related to the detection limit of the farm-level prevalence by the BTM ELISA test...

  19. Implementation of the - Constraint Method in Special Class of Multi-objective Fuzzy Bi-Level Nonlinear Problems

    Directory of Open Access Journals (Sweden)

    Azza Hassan Amer

    2017-12-01

    Full Text Available Geometric programming problem is a powerful tool for solving some special type nonlinear programming problems. In the last few years we have seen a very rapid development on solving multiobjective geometric programming problem. A few mathematical programming methods namely fuzzy programming, goal programming and weighting methods have been applied in the recent past to find the compromise solution. In this paper, -constraint method has been applied in bi-level multiobjective geometric programming problem to find the Pareto optimal solution at each level. The equivalent mathematical programming problems are formulated to find their corresponding value of the objective function based on the duality theorem at eash level. Here, we have developed a new algorithm for fuzzy programming technique to solve bi-level multiobjective geometric programming problems to find an optimal compromise solution. Finally the solution procedure of the fuzzy technique is illustrated by a numerical example

  20. Standard test method for nondestructive assay of special nuclear material holdup using Gamma-Ray spectroscopic methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes gamma-ray methods used to nondestructively measure the quantity of 235U, or 239Pu remaining as holdup in nuclear facilities. Holdup occurs in all facilities where nuclear material is processed, in process equipment, in exhaust ventilation systems and in building walls and floors. 1.2 This test method includes information useful for management, planning, selection of equipment, consideration of interferences, measurement program definition, and the utilization of resources (1, 2, 3, 4). 1.3 The measurement of nuclear material hold up in process equipment requires a scientific knowledge of radiation sources and detectors, transmission of radiation, calibration, facility operations and error analysis. It is subject to the constraints of the facility, management, budget, and schedule; plus health and safety requirements; as well as the laws of physics. The measurement process includes defining measurement uncertainties and is sensitive to the form and distribution of the material...