  1. Enhancing spatial detection accuracy for syndromic surveillance with street level incidence data

    Directory of Open Access Journals (Sweden)

    Alemi Farrokh

    2010-01-01

    Full Text Available Abstract Background The Department of Defense Military Health System operates a syndromic surveillance system that monitors medical records at more than 450 non-combat Military Treatment Facilities (MTF worldwide. The Electronic Surveillance System for Early Notification of Community-based Epidemics (ESSENCE uses both temporal and spatial algorithms to detect disease outbreaks. This study focuses on spatial detection and attempts to improve the effectiveness of the ESSENCE implementation of the spatial scan statistic by increasing the spatial resolution of incidence data from zip codes to street address level. Methods Influenza-Like Illness (ILI was used as a test syndrome to develop methods to improve the spatial accuracy of detected alerts. Simulated incident clusters of various sizes were superimposed on real ILI incidents from the 2008/2009 influenza season. Clusters were detected using the spatial scan statistic and their displacement from simulated loci was measured. Detected cluster size distributions were also evaluated for compliance with simulated cluster sizes. Results Relative to the ESSENCE zip code based method, clusters detected using street level incidents were displaced on average 65% less for 2 and 5 mile radius clusters and 31% less for 10 mile radius clusters. Detected cluster size distributions for the street address method were quasi normal and sizes tended to slightly exceed simulated radii. ESSENCE methods yielded fragmented distributions and had high rates of zero radius and oversized clusters. Conclusions Spatial detection accuracy improved notably with regard to both location and size when incidents were geocoded to street addresses rather than zip code centroids. Since street address geocoding success rates were only 73.5%, zip codes were still used for more than one quarter of ILI cases. Thus, further advances in spatial detection accuracy are dependant on systematic improvements in the collection of individual

  2. Detection of the spatial accuracy of an O-arm in the region of surgical interest

    Science.gov (United States)

    Koivukangas, Tapani; Katisko, Jani P. A.; Koivukangsa, John P.

    2013-03-01

    Medical imaging is an essential component of a wide range of surgical procedures1. For image guided surgical (IGS) procedures, medical images are the main source of information2. The IGS procedures rely largely on obtained image data, so the data needs to provide differentiation between normal and abnormal tissues, especially when other surgical guidance devices are used in the procedures. The image data also needs to provide accurate spatial representation of the patient3. This research has concentrated on the concept of accuracy assessment of IGS devices to meet the needs of quality assurance in the hospital environment. For this purpose, two precision engineered accuracy assessment phantoms have been developed as advanced materials and methods for the community. The phantoms were designed to mimic the volume of a human head as the common region of surgical interest (ROSI). This paper introduces the utilization of the phantoms in spatial accuracy assessment of a commercial surgical 3D CT scanner, the O-Arm. The study presents methods and results of image quality detection of possible geometrical distortions in the region of surgical interest. The results show that in the pre-determined ROSI there are clear image distortion and artefacts using too high imaging parameters when scanning the objects. On the other hand, when using optimal parameters, the O-Arm causes minimal error in IGS accuracy. The detected spatial inaccuracy of the O-Arm with used parameters was in the range of less than 1.00 mm.

  3. Response-only method for damage detection of beam-like structures using high accuracy frequencies with auxiliary mass spatial probing

    Science.gov (United States)

    Zhong, Shuncong; Oyadiji, S. Olutunde; Ding, Kang

    2008-04-01

    This paper proposes a new approach based on auxiliary mass spatial probing using spectral centre correction method (SCCM), to provide a simple solution for damage detection by just using the response time history of beam-like structures. The natural frequencies of a damaged beam with a traversing auxiliary mass change due to change in the inertia of the beam as the auxiliary mass is traversed along the beam, as well as the point-to-point variations in the flexibility of the beam. Therefore the auxiliary mass can enhance the effects of the crack on the dynamics of the beam and, therefore, facilitate the identification and location of damage in the beam. That is, the auxiliary mass can be used to probe the dynamic characteristic of the beam by traversing the mass from one end of the beam to the other. However, it is impossible to obtain accurate modal frequencies by the direct operation of the fast Fourier transform (FFT) of the response data of the structure because the frequency spectrum can be only calculated from limited sampled time data which results in the well-known leakage effect. SCCM is identical to the energy centrobaric correction method (ECCM) which is a practical and effective method used in rotating mechanical fault diagnosis and which resolves the shortcoming of FFT and can provide high accuracy estimate of frequency, amplitude and phase. In the present work, the modal responses of damaged simply supported beams with auxiliary mass are computed using the finite element method (FEM). The graphical plots of the natural frequencies calculated by SCCM versus axial location of auxiliary mass are obtained. However, it is difficult to locate the crack directly from the curve of natural frequencies. A simple and fast method, the derivatives of natural frequency curve, is proposed in the paper which can provide crack information for damage detection of beam-like structures. The efficiency and practicability of the proposed method is illustrated via numerical

  4. The importance of spatial accuracy in characterizing stand types ...

    African Journals Online (AJOL)

    This study assessed the potential use of Landsat 7 ETM+ (15 and 30 m spatial resolutions) images to estimate forest stand attributes such as development stages, crown closure and stand types. The study evaluates the performance of spatial and image classification accuracies between Landsat images (15 and 30 m ...

  5. Analysis of spatial distribution of land cover maps accuracy

    Science.gov (United States)

    Khatami, R.; Mountrakis, G.; Stehman, S. V.

    2017-12-01

    Land cover maps have become one of the most important products of remote sensing science. However, classification errors will exist in any classified map and affect the reliability of subsequent map usage. Moreover, classification accuracy often varies over different regions of a classified map. These variations of accuracy will affect the reliability of subsequent analyses of different regions based on the classified maps. The traditional approach of map accuracy assessment based on an error matrix does not capture the spatial variation in classification accuracy. Here, per-pixel accuracy prediction methods are proposed based on interpolating accuracy values from a test sample to produce wall-to-wall accuracy maps. Different accuracy prediction methods were developed based on four factors: predictive domain (spatial versus spectral), interpolation function (constant, linear, Gaussian, and logistic), incorporation of class information (interpolating each class separately versus grouping them together), and sample size. Incorporation of spectral domain as explanatory feature spaces of classification accuracy interpolation was done for the first time in this research. Performance of the prediction methods was evaluated using 26 test blocks, with 10 km × 10 km dimensions, dispersed throughout the United States. The performance of the predictions was evaluated using the area under the curve (AUC) of the receiver operating characteristic. Relative to existing accuracy prediction methods, our proposed methods resulted in improvements of AUC of 0.15 or greater. Evaluation of the four factors comprising the accuracy prediction methods demonstrated that: i) interpolations should be done separately for each class instead of grouping all classes together; ii) if an all-classes approach is used, the spectral domain will result in substantially greater AUC than the spatial domain; iii) for the smaller sample size and per-class predictions, the spectral and spatial domain

  6. Detecting spatial regimes in ecosystems

    Science.gov (United States)

    Sundstrom, Shana M.; Eason, Tarsha; Nelson, R. John; Angeler, David G.; Barichievy, Chris; Garmestani, Ahjond S.; Graham, Nicholas A.J.; Granholm, Dean; Gunderson, Lance; Knutson, Melinda; Nash, Kirsty L.; Spanbauer, Trisha; Stow, Craig A.; Allen, Craig R.

    2017-01-01

    Research on early warning indicators has generally focused on assessing temporal transitions with limited application of these methods to detecting spatial regimes. Traditional spatial boundary detection procedures that result in ecoregion maps are typically based on ecological potential (i.e. potential vegetation), and often fail to account for ongoing changes due to stressors such as land use change and climate change and their effects on plant and animal communities. We use Fisher information, an information theory-based method, on both terrestrial and aquatic animal data (U.S. Breeding Bird Survey and marine zooplankton) to identify ecological boundaries, and compare our results to traditional early warning indicators, conventional ecoregion maps and multivariate analyses such as nMDS and cluster analysis. We successfully detected spatial regimes and transitions in both terrestrial and aquatic systems using Fisher information. Furthermore, Fisher information provided explicit spatial information about community change that is absent from other multivariate approaches. Our results suggest that defining spatial regimes based on animal communities may better reflect ecological reality than do traditional ecoregion maps, especially in our current era of rapid and unpredictable ecological change.

  7. Research on Horizontal Accuracy Method of High Spatial Resolution Remotely Sensed Orthophoto Image

    Science.gov (United States)

    Xu, Y. M.; Zhang, J. X.; Yu, F.; Dong, S.

    2018-04-01

    At present, in the inspection and acceptance of high spatial resolution remotly sensed orthophoto image, the horizontal accuracy detection is testing and evaluating the accuracy of images, which mostly based on a set of testing points with the same accuracy and reliability. However, it is difficult to get a set of testing points with the same accuracy and reliability in the areas where the field measurement is difficult and the reference data with high accuracy is not enough. So it is difficult to test and evaluate the horizontal accuracy of the orthophoto image. The uncertainty of the horizontal accuracy has become a bottleneck for the application of satellite borne high-resolution remote sensing image and the scope of service expansion. Therefore, this paper proposes a new method to test the horizontal accuracy of orthophoto image. This method using the testing points with different accuracy and reliability. These points' source is high accuracy reference data and field measurement. The new method solves the horizontal accuracy detection of the orthophoto image in the difficult areas and provides the basis for providing reliable orthophoto images to the users.

  8. Accuracy of CNV Detection from GWAS Data.

    Directory of Open Access Journals (Sweden)

    Dandan Zhang

    2011-01-01

    Full Text Available Several computer programs are available for detecting copy number variants (CNVs using genome-wide SNP arrays. We evaluated the performance of four CNV detection software suites--Birdsuite, Partek, HelixTree, and PennCNV-Affy--in the identification of both rare and common CNVs. Each program's performance was assessed in two ways. The first was its recovery rate, i.e., its ability to call 893 CNVs previously identified in eight HapMap samples by paired-end sequencing of whole-genome fosmid clones, and 51,440 CNVs identified by array Comparative Genome Hybridization (aCGH followed by validation procedures, in 90 HapMap CEU samples. The second evaluation was program performance calling rare and common CNVs in the Bipolar Genome Study (BiGS data set (1001 bipolar cases and 1033 controls, all of European ancestry as measured by the Affymetrix SNP 6.0 array. Accuracy in calling rare CNVs was assessed by positive predictive value, based on the proportion of rare CNVs validated by quantitative real-time PCR (qPCR, while accuracy in calling common CNVs was assessed by false positive/false negative rates based on qPCR validation results from a subset of common CNVs. Birdsuite recovered the highest percentages of known HapMap CNVs containing >20 markers in two reference CNV datasets. The recovery rate increased with decreased CNV frequency. In the tested rare CNV data, Birdsuite and Partek had higher positive predictive values than the other software suites. In a test of three common CNVs in the BiGS dataset, Birdsuite's call was 98.8% consistent with qPCR quantification in one CNV region, but the other two regions showed an unacceptable degree of accuracy. We found relatively poor consistency between the two "gold standards," the sequence data of Kidd et al., and aCGH data of Conrad et al. Algorithms for calling CNVs especially common ones need substantial improvement, and a "gold standard" for detection of CNVs remains to be established.

  9. Spatial filtering precedes motion detection.

    Science.gov (United States)

    Morgan, M J

    1992-01-23

    When we perceive motion on a television or cinema screen, there must be some process that allows us to track moving objects over time: if not, the result would be a conflicting mass of motion signals in all directions. A possible mechanism, suggested by studies of motion displacement in spatially random patterns, is that low-level motion detectors have a limited spatial range, which ensures that they tend to be stimulated over time by the same object. This model predicts that the direction of displacement of random patterns cannot be detected reliably above a critical absolute displacement value (Dmax) that is independent of the size or density of elements in the display. It has been inferred that Dmax is a measure of the size of motion detectors in the visual pathway. Other studies, however, have shown that Dmax increases with element size, in which case the most likely interpretation is that Dmax depends on the probability of false matches between pattern elements following a displacement. These conflicting accounts are reconciled here by showing that Dmax is indeed determined by the spacing between the elements in the pattern, but only after fine detail has been removed by a physiological prefiltering stage: the filter required to explain the data has a similar size to the receptive field of neurons in the primate magnocellular pathway. The model explains why Dmax can be increased by removing high spatial frequencies from random patterns, and simplifies our view of early motion detection.

  10. Improving the accuracy of livestock distribution estimates through spatial interpolation.

    Science.gov (United States)

    Bryssinckx, Ward; Ducheyne, Els; Muhwezi, Bernard; Godfrey, Sunday; Mintiens, Koen; Leirs, Herwig; Hendrickx, Guy

    2012-11-01

    Animal distribution maps serve many purposes such as estimating transmission risk of zoonotic pathogens to both animals and humans. The reliability and usability of such maps is highly dependent on the quality of the input data. However, decisions on how to perform livestock surveys are often based on previous work without considering possible consequences. A better understanding of the impact of using different sample designs and processing steps on the accuracy of livestock distribution estimates was acquired through iterative experiments using detailed survey. The importance of sample size, sample design and aggregation is demonstrated and spatial interpolation is presented as a potential way to improve cattle number estimates. As expected, results show that an increasing sample size increased the precision of cattle number estimates but these improvements were mainly seen when the initial sample size was relatively low (e.g. a median relative error decrease of 0.04% per sampled parish for sample sizes below 500 parishes). For higher sample sizes, the added value of further increasing the number of samples declined rapidly (e.g. a median relative error decrease of 0.01% per sampled parish for sample sizes above 500 parishes. When a two-stage stratified sample design was applied to yield more evenly distributed samples, accuracy levels were higher for low sample densities and stabilised at lower sample sizes compared to one-stage stratified sampling. Aggregating the resulting cattle number estimates yielded significantly more accurate results because of averaging under- and over-estimates (e.g. when aggregating cattle number estimates from subcounty to district level, P interpolation to fill in missing values in non-sampled areas, accuracy is improved remarkably. This counts especially for low sample sizes and spatially even distributed samples (e.g. P <0.001 for a sample of 170 parishes using one-stage stratified sampling and aggregation on district level

  11. Content in Context Improves Deception Detection Accuracy

    Science.gov (United States)

    Blair, J. Pete; Levine, Timothy R.; Shaw, Allison S.

    2010-01-01

    Past research has shown that people are only slightly better than chance at distinguishing truths from lies. Higher accuracy rates, however, are possible when contextual knowledge is used to judge the veracity of situated message content. The utility of content in context was shown in a series of experiments with students (N = 26, 45, 51, 25, 127)…

  12. Pixels, Blocks of Pixels, and Polygons: Choosing a Spatial Unit for Thematic Accuracy Assessment

    Science.gov (United States)

    Pixels, polygons, and blocks of pixels are all potentially viable spatial assessment units for conducting an accuracy assessment. We develop a statistical population-based framework to examine how the spatial unit chosen affects the outcome of an accuracy assessment. The populati...

  13. Spatial Outlier Detection of CO2 Monitoring Data Based on Spatial Local Outlier Factor

    Directory of Open Access Journals (Sweden)

    Liu Xin

    2015-12-01

    Full Text Available Spatial local outlier factor (SLOF algorithm was adopted in this study for spatial outlier detection because of the limitations of the traditional static threshold detection. Based on the spatial characteristics of CO2 monitoring data obtained in the carbon capture and storage (CCS project, the K-Nearest Neighbour (KNN graph was constructed using the latitude and longitude information of the monitoring points to identify the spatial neighbourhood of the monitoring points. Then SLOF was adopted to calculate the outlier degrees of the monitoring points and the 3σ rule was employed to identify the spatial outlier. Finally, the selection of K value was analysed and the optimal one was selected. The results show that, compared with the static threshold method, the proposed algorithm has a higher detection precision. It can overcome the shortcomings of the static threshold method and improve the accuracy and diversity of local outlier detection, which provides a reliable reference for the safety assessment and warning of CCS monitoring.

  14. Detecting spatial regimes in ecosystems | Science Inventory ...

    Science.gov (United States)

    Research on early warning indicators has generally focused on assessing temporal transitions with limited application of these methods to detecting spatial regimes. Traditional spatial boundary detection procedures that result in ecoregion maps are typically based on ecological potential (i.e. potential vegetation), and often fail to account for ongoing changes due to stressors such as land use change and climate change and their effects on plant and animal communities. We use Fisher information, an information theory based method, on both terrestrial and aquatic animal data (US Breeding Bird Survey and marine zooplankton) to identify ecological boundaries, and compare our results to traditional early warning indicators, conventional ecoregion maps, and multivariate analysis such as nMDS (non-metric Multidimensional Scaling) and cluster analysis. We successfully detect spatial regimes and transitions in both terrestrial and aquatic systems using Fisher information. Furthermore, Fisher information provided explicit spatial information about community change that is absent from other multivariate approaches. Our results suggest that defining spatial regimes based on animal communities may better reflect ecological reality than do traditional ecoregion maps, especially in our current era of rapid and unpredictable ecological change. Use an information theory based method to identify ecological boundaries and compare our results to traditional early warning

  15. Spatial cluster detection using dynamic programming

    Directory of Open Access Journals (Sweden)

    Sverchkov Yuriy

    2012-03-01

    Full Text Available Abstract Background The task of spatial cluster detection involves finding spatial regions where some property deviates from the norm or the expected value. In a probabilistic setting this task can be expressed as finding a region where some event is significantly more likely than usual. Spatial cluster detection is of interest in fields such as biosurveillance, mining of astronomical data, military surveillance, and analysis of fMRI images. In almost all such applications we are interested both in the question of whether a cluster exists in the data, and if it exists, we are interested in finding the most accurate characterization of the cluster. Methods We present a general dynamic programming algorithm for grid-based spatial cluster detection. The algorithm can be used for both Bayesian maximum a-posteriori (MAP estimation of the most likely spatial distribution of clusters and Bayesian model averaging over a large space of spatial cluster distributions to compute the posterior probability of an unusual spatial clustering. The algorithm is explained and evaluated in the context of a biosurveillance application, specifically the detection and identification of Influenza outbreaks based on emergency department visits. A relatively simple underlying model is constructed for the purpose of evaluating the algorithm, and the algorithm is evaluated using the model and semi-synthetic test data. Results When compared to baseline methods, tests indicate that the new algorithm can improve MAP estimates under certain conditions: the greedy algorithm we compared our method to was found to be more sensitive to smaller outbreaks, while as the size of the outbreaks increases, in terms of area affected and proportion of individuals affected, our method overtakes the greedy algorithm in spatial precision and recall. The new algorithm performs on-par with baseline methods in the task of Bayesian model averaging. Conclusions We conclude that the dynamic

  16. The accuracy of extended histopathology to detect immunotoxic chemicals

    NARCIS (Netherlands)

    Germolec, D.R.; Kashon, M.; Nyska, A.; Kuper, C.F.; Portier, C.; Kommineni, C.; Johnson, K.A.; Luster, M.I.

    2004-01-01

    The accuracy of extended histopathology to detect immunotoxic chemicals in female B6C3F1 mice was evaluated under the auspices of the National Toxicology Program (NTP). A workgroup was formed consisting of four pathologists who conducted extended histopathological evaluation of lymphoid tissues

  17. Detecting accuracy of flaws by manual and automatic ultrasonic inspections

    International Nuclear Information System (INIS)

    Iida, K.

    1988-01-01

    As the final stage work in the nine year project on proving tests of the ultrasonic inspection technique applied to the ISI of LWR plants, automatic ultrasonic inspection tests were carried out on EDM notches, surface fatigue cracks, weld defects and stress corrosion cracks, which were deliberately introduced in full size structural components simulating a 1,100 MWe BWR. Investigated items are the performance of a newly assembled automatic inspection apparatus, detection limit of flaws, detection resolution of adjacent collinear or parallel EDM notches, detection reproducibility and detection accuracy. The manual ultrasonic inspection of the same flaws as inspected by the automatic ultrasonic inspection was also carried out in order to have comparative data. This paper reports how it was confirmed that the automatic ultrasonic inspection is much superior to the manual inspection in the flaw detection rate and in the detection reproducibility

  18. Higher-order Spatial Accuracy in Diffeomorphic Image Registration

    DEFF Research Database (Denmark)

    Jacobs, Henry O.; Sommer, Stefan

    -jets. We show that the solutions convergence to optimal solutions of the original cost functional as the number of particles increases with a convergence rate of O(hd+k) where h is a resolution parameter. The effect of this approach over traditional particle methods is illustrated on synthetic examples......We discretize a cost functional for image registration problems by deriving Taylor expansions for the matching term. Minima of the discretized cost functionals can be computed with no spatial discretization error, and the optimal solutions are equivalent to minimal energy curves in the space of kk...

  19. Pushing the limits of NAA. Accuracy, uncertainty and detection limits

    International Nuclear Information System (INIS)

    Greenberg, R.R.

    2008-01-01

    This paper describes some highlights from the author's efforts to improve neutron activation analysis (NAA) detection limits through development and optimization of radiochemical separations, as well as to improve the overall accuracy of NAA measurements by identifying, quantifying and reducing measurement biases and uncertainties. Efforts to demonstrate the metrological basis of NAA, and to establish it as a 'Primary Method of Measurement' will be discussed. (author)

  20. Accuracy, precision, and lower detection limits (a deficit reduction approach)

    International Nuclear Information System (INIS)

    Bishop, C.T.

    1993-01-01

    The evaluation of the accuracy, precision and lower detection limits of the determination of trace radionuclides in environmental samples can become quite sophisticated and time consuming. This in turn could add significant cost to the analyses being performed. In the present method, a open-quotes deficit reduction approachclose quotes has been taken to keep costs low, but at the same time provide defensible data. In order to measure the accuracy of a particular method, reference samples are measured over the time period that the actual samples are being analyzed. Using a Lotus spreadsheet, data are compiled and an average accuracy is computed. If pairs of reference samples are analyzed, then precision can also be evaluated from the duplicate data sets. The standard deviation can be calculated if the reference concentrations of the duplicates are all in the same general range. Laboratory blanks are used to estimate the lower detection limits. The lower detection limit is calculated as 4.65 times the standard deviation of a set of blank determinations made over a given period of time. A Lotus spreadsheet is again used to compile data and LDLs over different periods of time can be compared

  1. Technique of experimental evaluation of cloud environment attacks detection accuracy

    Directory of Open Access Journals (Sweden)

    Sergey A. Klimachev

    2018-05-01

    Full Text Available The article is devoted to research of efficiency evaluation of IDS used for dynamic and complex organizational and technical structure computing platform guard. The components of the platform have a set of heterogeneous parameters. Analysis of existing IDS evaluation technique revealed shortcomings in justification of quantitative metrics that describe the efficiency and reliability IDS resolving. This makes if difficult to prove IDS evaluation technique. The purpose of the study is to increase IDS evaluation objectivity. To achive the purpose it is necessary to develop the correct technique, tools, experimental stand. The article proposes the results of development and approbation of the technique of IDS efficiency evaluation and software for it. The technique is based on defining of optimal set of attack detection accuracy scores. The technique and the software allow solving problems of comparative analysis of IDS that have similar functionality. As a result of the research, a number of task have been solved, including the selection of universal quantitative metrics for attack detection accuracy evaluation, the defining of summarised attack detection accuracy evaluation metric based on defining of pareto-optimal set of scores that ensure the confidentiality, integrity and accessibility of cloud environment information and information resources,  the development of a functional model,  a functional scheme and a software for cloud environment IDS research.

  2. Visual Inspection Displays Good Accuracy for Detecting Caries Lesions

    DEFF Research Database (Denmark)

    Twetman, Svante

    2015-01-01

    /QUESTION: To evaluate the overall accuracy of visual methods for detecting caries lesions. SOURCE OF FUNDING: Brazilian government (Process 2012/17888-1). TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data LEVEL OF EVIDENCE: Level 1: Good-quality, patient-oriented evidence STRENGTH OF RECOMMENDATION......ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Visual inspection for caries detection: a systematic review and meta-analysis. Gimenez T, Piovesan C, Braga MM, Raggio DP, Deery C, Ricketts DN, Ekstrand DR, Mendes FM. J Dent Res 2015;94(7):895-904. REVIEWER: Svante Twetman, DDS, PhD, Odont Dr PURPOSE...

  3. Improved classification accuracy of powdery mildew infection levels of wine grapes by spatial-spectral analysis of hyperspectral images.

    Science.gov (United States)

    Knauer, Uwe; Matros, Andrea; Petrovic, Tijana; Zanker, Timothy; Scott, Eileen S; Seiffert, Udo

    2017-01-01

    , perhaps due to colonized berries or sparse mycelia hidden within the bunch or airborne conidia on the berries that were detected by qPCR. An advanced approach to hyperspectral image classification based on combined spatial and spectral image features, potentially applicable to many available hyperspectral sensor technologies, has been developed and validated to improve the detection of powdery mildew infection levels of Chardonnay grape bunches. The spatial-spectral approach improved especially the detection of light infection levels compared with pixel-wise spectral data analysis. This approach is expected to improve the speed and accuracy of disease detection once the thresholds for fungal biomass detected by hyperspectral imaging are established; it can also facilitate monitoring in plant phenotyping of grapevine and additional crops.

  4. Improving the Accuracy of Cloud Detection Using Machine Learning

    Science.gov (United States)

    Craddock, M. E.; Alliss, R. J.; Mason, M.

    2017-12-01

    show 97% accuracy during the daytime, 94% accuracy at night, and 95% accuracy for all times. The total time to train, tune and test was approximately one week. The improved performance and reduced time to produce results is testament to improved computer technology and the use of machine learning as a more efficient and accurate methodology of cloud detection.

  5. Spatial Component Position in Total Hip Arthroplasty. Accuracy and repeatability with a new CT method

    International Nuclear Information System (INIS)

    Olivecrona, H.

    2003-01-01

    Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically

  6. Spatial Component Position in Total Hip Arthroplasty. Accuracy and repeatability with a new CT method

    Energy Technology Data Exchange (ETDEWEB)

    Olivecrona, H. [Soedersjukhuset, Stockholm (Sweden). Dept. of Hand Surgery; Weidenhielm, L. [Karolinska Hospital, Stockholm (Sweden). Dept. of Orthopedics; Olivecrona, L. [Karolinska Hospital, Stockholm (Sweden). Dept. of Radiology; Noz, M.E. [New York Univ. School of Medicine, NY (United States). Dept. of Radiology; Maguire, G.Q. [Royal Inst. of Tech., Kista (Sweden). Inst. for Microelectronics and Information Technology; Zeleznik, M. P. [Univ. of Utah, Salt Lake City, UT (United States). Dept. of Radiation Oncology; Svensson, L. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Mathematics; Jonson, T. [Eskadern Foeretagsutveckling AB, Goeteborg (Sweden)

    2003-03-01

    Purpose: 3D detection of centerpoints of prosthetic cup and head after total hip arthroplasty (THA) using CT. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients after THA. Two independent examiners placed landmarks in images of the prosthetic cup and head. All landmarking was repeated after 1 week. Centerpoints were calculated and compared. Results: Within volumes, all measurements of centerpoints of cup and head fell, with a 95% confidence, within one CT-voxel of any other measurement of the same object. Across two volumes, the mean error of distance between center of cup and prosthetic head was 1.4 mm (SD 0.73). Intra- and interobserver 95% accuracy limit was below 2 mm within and below 3 mm across volumes. No difference between intra- and interobserver measurements occurred. A formula for converting finite sets of point landmarks in the radiolucent tread of the cup to a centerpoint was stable. The percent difference of the landmark distances from a calculated spherical surface was within one CT-voxel. This data was normally distributed and not dependent on observer or trial. Conclusion: The true 3D position of the centers of cup and prosthetic head can be detected using CT. Spatial relationship between the components can be analyzed visually and numerically.

  7. A reference dataset for deformable image registration spatial accuracy evaluation using the COPDgene study archive

    International Nuclear Information System (INIS)

    Castillo, Richard; Castillo, Edward; Wood, Abbie M; Ludwig, Michelle S; Guerrero, Thomas; Fuentes, David; Ahmad, Moiz

    2013-01-01

    Landmark point-pairs provide a strategy to assess deformable image registration (DIR) accuracy in terms of the spatial registration of the underlying anatomy depicted in medical images. In this study, we propose to augment a publicly available database (www.dir-lab.com) of medical images with large sets of manually identified anatomic feature pairs between breath-hold computed tomography (BH-CT) images for DIR spatial accuracy evaluation. Ten BH-CT image pairs were randomly selected from the COPDgene study cases. Each patient had received CT imaging of the entire thorax in the supine position at one-fourth dose normal expiration and maximum effort full dose inspiration. Using dedicated in-house software, an imaging expert manually identified large sets of anatomic feature pairs between images. Estimates of inter- and intra-observer spatial variation in feature localization were determined by repeat measurements of multiple observers over subsets of randomly selected features. 7298 anatomic landmark features were manually paired between the 10 sets of images. Quantity of feature pairs per case ranged from 447 to 1172. Average 3D Euclidean landmark displacements varied substantially among cases, ranging from 12.29 (SD: 6.39) to 30.90 (SD: 14.05) mm. Repeat registration of uniformly sampled subsets of 150 landmarks for each case yielded estimates of observer localization error, which ranged in average from 0.58 (SD: 0.87) to 1.06 (SD: 2.38) mm for each case. The additions to the online web database (www.dir-lab.com) described in this work will broaden the applicability of the reference data, providing a freely available common dataset for targeted critical evaluation of DIR spatial accuracy performance in multiple clinical settings. Estimates of observer variance in feature localization suggest consistent spatial accuracy for all observers across both four-dimensional CT and COPDgene patient cohorts. (paper)

  8. Diagnostic accuracy of fluorescence microlymphography for detecting limb lymphedema.

    Science.gov (United States)

    Keo, H H; Husmann, M; Groechenig, E; Willenberg, T; Gretener, S B

    2015-04-01

    Fluorescence microlymphography (FML) is a minimally invasive technique for visualization of the cutaneous lymphatic network. The aim of the study was to assess the accuracy and safety of FML in patients with unilateral lymphedema. This was a cross sectional study. Patients with unilateral leg swelling were assessed and compared with the unaffected contralateral limb. FML was performed in all index legs and the contralateral leg by injecting 0.1 mL of fluorescein isothiocyanate (FITC)-labeled dextran intradermally in both limbs at the same level. The most prominent swelling of the affected limb was the anatomical reference. The spread of the dye in the lymphatic capillaries of the skin was measured in all dimensions by epiluminator intravital microscopy and the maximum dye spread value 10 min after injection was used for statistical analysis. The contralateral leg served as control. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess threshold values that best predict lymphedema. Between March 2008 and February 2014 seventy patients with unilateral chronic leg swelling were clinically diagnosed with lymphedema. The median age was 45 (IQR 27-56) years. Of those, 46 (65.7%) were female and 71.4% had primary and 28.6% secondary lymphedema. Sensitivity, specificity, positive and negative likelihood ratio, and positive and negative predictive value were 94.3%, 78.6%, 4.40, 0.07, 81.5%, and 93.2% for the 12 mm cut off level and 91.4%, 85.7%, 6.40, 0.10, 86.5%, and 90.9% for the 14 mm cut off level, respectively. The area under the ROC curve was 0.89 (95% CI: 0.83-0.95). No major adverse events were observed. FML is an almost atraumatic and safe technique for detecting lymphedema in patients with leg swelling. In this series the greatest accuracy was observed at a cut off level of ≥14 mm maximum spread. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  9. Spatial Accuracy of Embedded Surface Coloring in Color 3D Printing

    DEFF Research Database (Denmark)

    Pedersen, David Bue; Hansen, Hans Nørgaard; Eiríksson, Eyþór Rúnar

    2015-01-01

    Measurement Machines(CMMʼs) and Machine Tools, that already hasbeen transferred to be applicable for AMmachine tools, [3] in order to determine the spatial accuracy of embedded color features to artifacts printed on a zCorp 650 color 3D Printer.The spatial color verification artifact is a flat platewith...... capable of full-color printing inpolymers[1]. Industrial service providers increasingly expand their product-range of full colorprint services, and as of today, the industry for full-color parts has grown rapidly, into a million-dollar industry [2]. With a new market emerging at such pace, it is believed...

  10. Spatial Outlier Detection of CO2 Monitoring Data Based on Spatial Local Outlier Factor

    OpenAIRE

    Liu Xin; Zhang Shaoliang; Zheng Pulin

    2015-01-01

    Spatial local outlier factor (SLOF) algorithm was adopted in this study for spatial outlier detection because of the limitations of the traditional static threshold detection. Based on the spatial characteristics of CO2 monitoring data obtained in the carbon capture and storage (CCS) project, the K-Nearest Neighbour (KNN) graph was constructed using the latitude and longitude information of the monitoring points to identify the spatial neighbourhood of the monitoring points. Then ...

  11. Detection Accuracy of Collective Intelligence Assessments for Skin Cancer Diagnosis.

    Science.gov (United States)

    Kurvers, Ralf H J M; Krause, Jens; Argenziano, Giuseppe; Zalaudek, Iris; Wolf, Max

    2015-12-01

    Incidence rates of skin cancer are increasing globally, and the correct classification of skin lesions (SLs) into benign and malignant tissue remains a continuous challenge. A collective intelligence approach to skin cancer detection may improve accuracy. To evaluate the performance of 2 well-known collective intelligence rules (majority rule and quorum rule) that combine the independent conclusions of multiple decision makers into a single decision. Evaluations were obtained from 2 large and independent data sets. The first data set consisted of 40 experienced dermoscopists, each of whom independently evaluated 108 images of SLs during the Consensus Net Meeting of 2000. The second data set consisted of 82 medical professionals with varying degrees of dermatology experience, each of whom evaluated a minimum of 110 SLs. All SLs were evaluated via the Internet. Image selection of SLs was based on high image quality and the presence of histopathologic information. Data were collected from July through October 2000 for study 1 and from February 2003 through January 2004 for study 2 and evaluated from January 5 through August 7, 2015. For both collective intelligence rules, we determined the true-positive rate (ie, the hit rate or specificity) and the false-positive rate (ie, the false-alarm rate or 1 - sensitivity) and compared these rates with the performance of single decision makers. Furthermore, we evaluated the effect of group size on true- and false-positive rates. One hundred twenty-two medical professionals performed 16 029 evaluations. Use of either collective intelligence rule consistently outperformed single decision makers. The groups achieved an increased true-positive rate and a decreased false-positive rate. For example, individual decision makers in study 1, using the pattern analysis as diagnostic algorithm, achieved a true-positive rate of 0.83 and a false-positive rate of 0.17. Groups of 3 individuals achieved a true-positive rate of 0.91 and a

  12. Accuracy and impact of spatial aids based upon satellite enumeration to improve indoor residual spraying spatial coverage.

    Science.gov (United States)

    Bridges, Daniel J; Pollard, Derek; Winters, Anna M; Winters, Benjamin; Sikaala, Chadwick; Renn, Silvia; Larsen, David A

    2018-02-23

    Indoor residual spraying (IRS) is a key tool in the fight to control, eliminate and ultimately eradicate malaria. IRS protection is based on a communal effect such that an individual's protection primarily relies on the community-level coverage of IRS with limited protection being provided by household-level coverage. To ensure a communal effect is achieved through IRS, achieving high and uniform community-level coverage should be the ultimate priority of an IRS campaign. Ensuring high community-level coverage of IRS in malaria-endemic areas is challenging given the lack of information available about both the location and number of households needing IRS in any given area. A process termed 'mSpray' has been developed and implemented and involves use of satellite imagery for enumeration for planning IRS and a mobile application to guide IRS implementation. This study assessed (1) the accuracy of the satellite enumeration and (2) how various degrees of spatial aid provided through the mSpray process affected community-level IRS coverage during the 2015 spray campaign in Zambia. A 2-stage sampling process was applied to assess accuracy of satellite enumeration to determine number and location of sprayable structures. Results indicated an overall sensitivity of 94% for satellite enumeration compared to finding structures on the ground. After adjusting for structure size, roof, and wall type, households in Nchelenge District where all types of satellite-based spatial aids (paper-based maps plus use of the mobile mSpray application) were used were more likely to have received IRS than Kasama district where maps used were not based on satellite enumeration. The probability of a household being sprayed in Nchelenge district where tablet-based maps were used, did not differ statistically from that of a household in Samfya District, where detailed paper-based spatial aids based on satellite enumeration were provided. IRS coverage from the 2015 spray season benefited from

  13. Magnetoencephalographic accuracy profiles for the detection of auditory pathway sources.

    Science.gov (United States)

    Bauer, Martin; Trahms, Lutz; Sander, Tilmann

    2015-04-01

    The detection limits for cortical and brain stem sources associated with the auditory pathway are examined in order to analyse brain responses at the limits of the audible frequency range. The results obtained from this study are also relevant to other issues of auditory brain research. A complementary approach consisting of recordings of magnetoencephalographic (MEG) data and simulations of magnetic field distributions is presented in this work. A biomagnetic phantom consisting of a spherical volume filled with a saline solution and four current dipoles is built. The magnetic fields outside of the phantom generated by the current dipoles are then measured for a range of applied electric dipole moments with a planar multichannel SQUID magnetometer device and a helmet MEG gradiometer device. The inclusion of a magnetometer system is expected to be more sensitive to brain stem sources compared with a gradiometer system. The same electrical and geometrical configuration is simulated in a forward calculation. From both the measured and the simulated data, the dipole positions are estimated using an inverse calculation. Results are obtained for the reconstruction accuracy as a function of applied electric dipole moment and depth of the current dipole. We found that both systems can localize cortical and subcortical sources at physiological dipole strength even for brain stem sources. Further, we found that a planar magnetometer system is more suitable if the position of the brain source can be restricted in a limited region of the brain. If this is not the case, a helmet-shaped sensor system offers more accurate source estimation.

  14. Color camera computed tomography imaging spectrometer for improved spatial-spectral image accuracy

    Science.gov (United States)

    Wilson, Daniel W. (Inventor); Bearman, Gregory H. (Inventor); Johnson, William R. (Inventor)

    2011-01-01

    Computed tomography imaging spectrometers ("CTIS"s) having color focal plane array detectors are provided. The color FPA detector may comprise a digital color camera including a digital image sensor, such as a Foveon X3.RTM. digital image sensor or a Bayer color filter mosaic. In another embodiment, the CTIS includes a pattern imposed either directly on the object scene being imaged or at the field stop aperture. The use of a color FPA detector and the pattern improves the accuracy of the captured spatial and spectral information.

  15. Accuracy of self-report in detecting taste dysfunction.

    Science.gov (United States)

    Soter, Ana; Kim, John; Jackman, Alexis; Tourbier, Isabelle; Kaul, Arti; Doty, Richard L

    2008-04-01

    To determine the sensitivity, specificity, and positive and negative predictive value of responses to the following questionnaire statements in detecting taste loss: "I can detect salt in chips, pretzels, or salted nuts," "I can detect sourness in vinegar, pickles, or lemon," "I can detect sweetness in soda, cookies, or ice cream," and "I can detect bitterness, in coffee, beer, or tonic water." Responses to an additional item, "I can detect chocolate in cocoa, cake or candy," was examined to determine whether patients clearly differentiate between taste loss and flavor loss secondary to olfactory dysfunction. A total of 469 patients (207 men, mean age = 54 years, standard deviation = 15 years; and 262 women, mean age = 54 years, standard deviation = 14 years) were administered a questionnaire containing these questions with the response categories of "easily," "somewhat," and "not at all," followed by a comprehensive taste and smell test battery. The questionnaire items poorly detected bona fide taste problems. However, they were sensitive in detecting persons without such problems (i.e., they exhibited low positive but high negative predictive value). Dysfunction categories of the University of Pennsylvania Smell Identification Test (UPSIT) were not meaningfully related to subjects' responses to the questionnaire statements. Both sex and age influenced performance on most of the taste tests, with older persons performing more poorly than younger ones and women typically outperforming men. Although it is commonly assumed that straight-forward questions concerning taste may be useful in detecting taste disorders, this study suggests this is not the case. However, patients who specifically report having no problems with taste perception usually do not exhibit taste dysfunction. The difficulty in detecting true taste problems by focused questionnaire items likely reflects a combination of factors. These include the relatively low prevalence of taste deficits in the

  16. The space-math link in preschool boys and girls: Importance of mental transformation, targeting accuracy, and spatial anxiety.

    Science.gov (United States)

    Wong, Wang I

    2017-06-01

    Spatial abilities are pertinent to mathematical competence, but evidence of the space-math link has largely been confined to older samples and intrinsic spatial abilities (e.g., mental transformation). The roles of gender and affective factors are also unclear. This study examined the correlations between counting ability, mental transformation, and targeting accuracy in 182 Hong Kong preschoolers, and whether these relationships were weaker at higher spatial anxiety levels. Both spatial abilities related with counting similarly for boys and girls. Targeting accuracy also mediated the male advantage in counting. Interestingly, spatial anxiety moderated the space-math links, but differently for boys and girls. For boys, spatial abilities were irrelevant to counting at high anxiety levels; for girls, the role of anxiety on the space-math link is less clear. Results extend the evidence base of the space-math link to include an extrinsic spatial ability (targeting accuracy) and have implications for intervention programmes. Statement of contribution What is already known on this subject? Much evidence of a space-math link in adolescent and adult samples and for intrinsic spatial abilities. What does this study add? Extended the space-math link to include both intrinsic and extrinsic spatial abilities in a preschool sample. Showed how spatial anxiety moderated the space-math link differently for boys and girls. © 2016 The British Psychological Society.

  17. The accuracy of transvaginal sonography to detect endometriosis cyst

    Science.gov (United States)

    Diantika, M.; Gunardi, E. R.

    2017-08-01

    Endometriosis is common in women of reproductive age. Late diagnosis is still the main concern. Currently, noninvasive diagnostic testing, such as transvaginal sonography, is recommended. The aim of the current study was to evaluate the accuracy of transvaginal sonography in diagnosing endometrial cysts in patients in Cipto Mangunkusumo Hospital, Jakarta, Indonesia. This diagnostic study was carried out at Cipto Mangunkusumo Hospital between January 2014 and June 2015. Outpatients suspected have an endometrial cyst based on the patient history and a clinical examination was recruited. The patients were then evaluated using transvaginal sonography by an experienced sonologist, according to the research protocol. The gold standard test was a histological finding in the removed surgical mass. Ninety-eight patients were analyzed. An endometrial cyst was confirmed by histology in 85 patients (87%). The accuracy, sensitivity, specificity, positive predictive value and negative predictive value of transvaginal sonography was established to be 85% (a range of 71-99%), 93%, 77%, 96%, and 63%, respectively. A significantly higher area under the curve was identified using transvaginal sonogpraphy compared to that achieved with a clinical examination alone (85% versus 79%). Transvaginal sonography was useful in diagnosing endometrial cysts in outpatients and is recommended in daily clinical practice.

  18. Trace element analysis by EPMA in geosciences: detection limit, precision and accuracy

    Science.gov (United States)

    Batanova, V. G.; Sobolev, A. V.; Magnin, V.

    2018-01-01

    Use of the electron probe microanalyser (EPMA) for trace element analysis has increased over the last decade, mainly because of improved stability of spectrometers and the electron column when operated at high probe current; development of new large-area crystal monochromators and ultra-high count rate spectrometers; full integration of energy-dispersive / wavelength-dispersive X-ray spectrometry (EDS/WDS) signals; and the development of powerful software packages. For phases that are stable under a dense electron beam, the detection limit and precision can be decreased to the ppm level by using high acceleration voltage and beam current combined with long counting time. Data on 10 elements (Na, Al, P, Ca, Ti, Cr, Mn, Co, Ni, Zn) in olivine obtained on a JEOL JXA-8230 microprobe with tungsten filament show that the detection limit decreases proportionally to the square root of counting time and probe current. For all elements equal or heavier than phosphorus (Z = 15), the detection limit decreases with increasing accelerating voltage. The analytical precision for minor and trace elements analysed in olivine at 25 kV accelerating voltage and 900 nA beam current is 4 - 18 ppm (2 standard deviations of repeated measurements of the olivine reference sample) and is similar to the detection limit of corresponding elements. To analyse trace elements accurately requires careful estimation of background, and consideration of sample damage under the beam and secondary fluorescence from phase boundaries. The development and use of matrix reference samples with well-characterised trace elements of interest is important for monitoring and improving of the accuracy. An evaluation of the accuracy of trace element analyses in olivine has been made by comparing EPMA data for new reference samples with data obtained by different in-situ and bulk analytical methods in six different laboratories worldwide. For all elements, the measured concentrations in the olivine reference sample

  19. Antibiotic Resistome: Improving Detection and Quantification Accuracy for Comparative Metagenomics.

    Science.gov (United States)

    Elbehery, Ali H A; Aziz, Ramy K; Siam, Rania

    2016-04-01

    The unprecedented rise of life-threatening antibiotic resistance (AR), combined with the unparalleled advances in DNA sequencing of genomes and metagenomes, has pushed the need for in silico detection of the resistance potential of clinical and environmental metagenomic samples through the quantification of AR genes (i.e., genes conferring antibiotic resistance). Therefore, determining an optimal methodology to quantitatively and accurately assess AR genes in a given environment is pivotal. Here, we optimized and improved existing AR detection methodologies from metagenomic datasets to properly consider AR-generating mutations in antibiotic target genes. Through comparative metagenomic analysis of previously published AR gene abundance in three publicly available metagenomes, we illustrate how mutation-generated resistance genes are either falsely assigned or neglected, which alters the detection and quantitation of the antibiotic resistome. In addition, we inspected factors influencing the outcome of AR gene quantification using metagenome simulation experiments, and identified that genome size, AR gene length, total number of metagenomics reads and selected sequencing platforms had pronounced effects on the level of detected AR. In conclusion, our proposed improvements in the current methodologies for accurate AR detection and resistome assessment show reliable results when tested on real and simulated metagenomic datasets.

  20. Cluster Detection Tests in Spatial Epidemiology: A Global Indicator for Performance Assessment.

    Directory of Open Access Journals (Sweden)

    Aline Guttmann

    Full Text Available In cluster detection of disease, the use of local cluster detection tests (CDTs is current. These methods aim both at locating likely clusters and testing for their statistical significance. New or improved CDTs are regularly proposed to epidemiologists and must be subjected to performance assessment. Because location accuracy has to be considered, performance assessment goes beyond the raw estimation of type I or II errors. As no consensus exists for performance evaluations, heterogeneous methods are used, and therefore studies are rarely comparable. A global indicator of performance, which assesses both spatial accuracy and usual power, would facilitate the exploration of CDTs behaviour and help between-studies comparisons. The Tanimoto coefficient (TC is a well-known measure of similarity that can assess location accuracy but only for one detected cluster. In a simulation study, performance is measured for many tests. From the TC, we here propose two statistics, the averaged TC and the cumulated TC, as indicators able to provide a global overview of CDTs performance for both usual power and location accuracy. We evidence the properties of these two indicators and the superiority of the cumulated TC to assess performance. We tested these indicators to conduct a systematic spatial assessment displayed through performance maps.

  1. Cluster Detection Tests in Spatial Epidemiology: A Global Indicator for Performance Assessment

    Science.gov (United States)

    Guttmann, Aline; Li, Xinran; Feschet, Fabien; Gaudart, Jean; Demongeot, Jacques; Boire, Jean-Yves; Ouchchane, Lemlih

    2015-01-01

    In cluster detection of disease, the use of local cluster detection tests (CDTs) is current. These methods aim both at locating likely clusters and testing for their statistical significance. New or improved CDTs are regularly proposed to epidemiologists and must be subjected to performance assessment. Because location accuracy has to be considered, performance assessment goes beyond the raw estimation of type I or II errors. As no consensus exists for performance evaluations, heterogeneous methods are used, and therefore studies are rarely comparable. A global indicator of performance, which assesses both spatial accuracy and usual power, would facilitate the exploration of CDTs behaviour and help between-studies comparisons. The Tanimoto coefficient (TC) is a well-known measure of similarity that can assess location accuracy but only for one detected cluster. In a simulation study, performance is measured for many tests. From the TC, we here propose two statistics, the averaged TC and the cumulated TC, as indicators able to provide a global overview of CDTs performance for both usual power and location accuracy. We evidence the properties of these two indicators and the superiority of the cumulated TC to assess performance. We tested these indicators to conduct a systematic spatial assessment displayed through performance maps. PMID:26086911

  2. Accuracy comparison among different machine learning techniques for detecting malicious codes

    Science.gov (United States)

    Narang, Komal

    2016-03-01

    In this paper, a machine learning based model for malware detection is proposed. It can detect newly released malware i.e. zero day attack by analyzing operation codes on Android operating system. The accuracy of Naïve Bayes, Support Vector Machine (SVM) and Neural Network for detecting malicious code has been compared for the proposed model. In the experiment 400 benign files, 100 system files and 500 malicious files have been used to construct the model. The model yields the best accuracy 88.9% when neural network is used as classifier and achieved 95% and 82.8% accuracy for sensitivity and specificity respectively.

  3. The Analysis of Burrows Recognition Accuracy in XINJIANG'S Pasture Area Based on Uav Visible Images with Different Spatial Resolution

    Science.gov (United States)

    Sun, D.; Zheng, J. H.; Ma, T.; Chen, J. J.; Li, X.

    2018-04-01

    The rodent disaster is one of the main biological disasters in grassland in northern Xinjiang. The eating and digging behaviors will cause the destruction of ground vegetation, which seriously affected the development of animal husbandry and grassland ecological security. UAV low altitude remote sensing, as an emerging technique with high spatial resolution, can effectively recognize the burrows. However, how to select the appropriate spatial resolution to monitor the calamity of the rodent disaster is the first problem we need to pay attention to. The purpose of this study is to explore the optimal spatial scale on identification of the burrows by evaluating the impact of different spatial resolution for the burrows identification accuracy. In this study, we shoot burrows from different flight heights to obtain visible images of different spatial resolution. Then an object-oriented method is used to identify the caves, and we also evaluate the accuracy of the classification. We found that the highest classification accuracy of holes, the average has reached more than 80 %. At the altitude of 24 m and the spatial resolution of 1cm, the accuracy of the classification is the highest We have created a unique and effective way to identify burrows by using UAVs visible images. We draw the following conclusion: the best spatial resolution of burrows recognition is 1 cm using DJI PHANTOM-3 UAV, and the improvement of spatial resolution does not necessarily lead to the improvement of classification accuracy. This study lays the foundation for future research and can be extended to similar studies elsewhere.

  4. Incrementally Detecting Change Types of Spatial Area Object: A Hierarchical Matching Method Considering Change Process

    Directory of Open Access Journals (Sweden)

    Yanhui Wang

    2018-01-01

    Full Text Available Detecting and extracting the change types of spatial area objects can track area objects’ spatiotemporal change pattern and provide the change backtracking mechanism for incrementally updating spatial datasets. To respond to the problems of high complexity of detection methods, high redundancy rate of detection factors, and the low automation degree during incrementally update process, we take into account the change process of area objects in an integrated way and propose a hierarchical matching method to detect the nine types of changes of area objects, while minimizing the complexity of the algorithm and the redundancy rate of detection factors. We illustrate in details the identification, extraction, and database entry of change types, and how we achieve a close connection and organic coupling of incremental information extraction and object type-of-change detection so as to characterize the whole change process. The experimental results show that this method can successfully detect incremental information about area objects in practical applications, with the overall accuracy reaching above 90%, which is much higher than the existing weighted matching method, making it quite feasible and applicable. It helps establish the corresponding relation between new-version and old-version objects, and facilitate the linked update processing and quality control of spatial data.

  5. Incorporating Spatial Information for Microaneurysm Detection in Retinal Images

    Directory of Open Access Journals (Sweden)

    Mohamed M. Habib

    2017-06-01

    Full Text Available The presence of microaneurysms(MAs in retinal images is a pathognomonic sign of Diabetic Retinopathy (DR. This is one of the leading causes of blindness in the working population worldwide. This paper introduces a novel algorithm that combines information from spatial views of the retina for the purpose of MA detection. Most published research in the literature has addressed the problem of detecting MAs from single retinal images. This work proposes the incorporation of information from two spatial views during the detection process. The algorithm is evaluated using 160 images from 40 patients seen as part of a UK diabetic eye screening programme which contained 207 MAs. An improvement in performance compared to detection from an algorithm that relies on a single image is shown as an increase of 2% ROC score, hence demonstrating the potential of this method.

  6. Inverse modeling applied to Scanning Capacitance Microscopy for improved spatial resolution and accuracy

    International Nuclear Information System (INIS)

    McMurray, J. S.; Williams, C. C.

    1998-01-01

    Scanning Capacitance Microscopy (SCM) is capable of providing two-dimensional information about dopant and carrier concentrations in semiconducting devices. This information can be used to calibrate models used in the simulation of these devices prior to manufacturing and to develop and optimize the manufacturing processes. To provide information for future generations of devices, ultra-high spatial accuracy (<10 nm) will be required. One method, which potentially provides a means to obtain these goals, is inverse modeling of SCM data. Current semiconducting devices have large dopant gradients. As a consequence, the capacitance probe signal represents an average over the local dopant gradient. Conversion of the SCM signal to dopant density has previously been accomplished with a physical model which assumes that no dopant gradient exists in the sampling area of the tip. The conversion of data using this model produces results for abrupt profiles which do not have adequate resolution and accuracy. A new inverse model and iterative method has been developed to obtain higher resolution and accuracy from the same SCM data. This model has been used to simulate the capacitance signal obtained from one and two-dimensional ideal abrupt profiles. This simulated data has been input to a new iterative conversion algorithm, which has recovered the original profiles in both one and two dimensions. In addition, it is found that the shape of the tip can significantly impact resolution. Currently SCM tips are found to degrade very rapidly. Initially the apex of the tip is approximately hemispherical, but quickly becomes flat. This flat region often has a radius of about the original hemispherical radius. This change in geometry causes the silicon directly under the disk to be sampled with approximately equal weight. In contrast, a hemispherical geometry samples most strongly the silicon centered under the SCM tip and falls off quickly with distance from the tip's apex. Simulation

  7. Spatial-Temporal Event Detection from Geo-Tagged Tweets

    Directory of Open Access Journals (Sweden)

    Yuqian Huang

    2018-04-01

    Full Text Available As one of the most popular social networking services in the world, Twitter allows users to post messages along with their current geographic locations. Such georeferenced or geo-tagged Twitter datasets can benefit location-based services, targeted advertising and geosocial studies. Our study focused on the detection of small-scale spatial-temporal events and their textual content. First, we used Spatial-Temporal Density-Based Spatial Clustering of Applications with Noise (ST-DBSCAN to spatially-temporally cluster the tweets. Then, the word frequencies were summarized for each cluster and the potential topics were modeled by the Latent Dirichlet Allocation (LDA algorithm. Using two years of Twitter data from four college cities in the U.S., we were able to determine the spatial-temporal patterns of two known events, two unknown events and one recurring event, which then were further explored and modeled to identify the semantic content about the events. This paper presents our process and recommendations for both finding event-related tweets as well as understanding the spatial-temporal behaviors and semantic natures of the detected events.

  8. Breast cancer mitosis detection in histopathological images with spatial feature extraction

    Science.gov (United States)

    Albayrak, Abdülkadir; Bilgin, Gökhan

    2013-12-01

    In this work, cellular mitosis detection in histopathological images has been investigated. Mitosis detection is very expensive and time consuming process. Development of digital imaging in pathology has enabled reasonable and effective solution to this problem. Segmentation of digital images provides easier analysis of cell structures in histopathological data. To differentiate normal and mitotic cells in histopathological images, feature extraction step is very crucial step for the system accuracy. A mitotic cell has more distinctive textural dissimilarities than the other normal cells. Hence, it is important to incorporate spatial information in feature extraction or in post-processing steps. As a main part of this study, Haralick texture descriptor has been proposed with different spatial window sizes in RGB and La*b* color spaces. So, spatial dependencies of normal and mitotic cellular pixels can be evaluated within different pixel neighborhoods. Extracted features are compared with various sample sizes by Support Vector Machines using k-fold cross validation method. According to the represented results, it has been shown that separation accuracy on mitotic and non-mitotic cellular pixels gets better with the increasing size of spatial window.

  9. Accuracy of hiatal hernia detection with esophageal high-resolution manometry

    NARCIS (Netherlands)

    Weijenborg, P. W.; van Hoeij, F. B.; Smout, A. J. P. M.; Bredenoord, A. J.

    2015-01-01

    The diagnosis of a sliding hiatal hernia is classically made with endoscopy or barium esophagogram. Spatial separation of the lower esophageal sphincter (LES) and diaphragm, the hallmark of hiatal hernia, can also be observed on high-resolution manometry (HRM), but the diagnostic accuracy of this

  10. Neutron Transport in Spatially Random Media: An Assessment of the Accuracy of First Order Smoothing

    International Nuclear Information System (INIS)

    Williams, M.M.R.

    2000-01-01

    A formalism has been developed for studying the transmission of neutrons through a spatially stochastic medium. The stochastic components are represented by absorbing plates of randomly varying strength and random position. This type of geometry enables the Feinberg-Galanin-Horning method to be employed and leads to the solution of a coupled set of linear equations for the flux at the plate positions. The matrix of the coefficients contains members that are random and these are solved by simulation. That is, the strength and plate positions are sampled from uniform distributions and the equations solved many times (in this case 10 5 simulations are carried out). Probability distributions for the plate transmission and reflection factors are constructed from which the mean and variance can be computed.These essentially exact solutions enable closure approximations to be assessed for accuracy. To this end, we have compared the mean and variance obtained from the first order smoothing approximation of Keller with the exact results and have found excellent agreement for the mean values but note deviations of up to 40% for the variance. Nevertheless, for the problems considered here, first order smoothing appears to be of practical value and is very efficient numerically in comparison with simulation

  11. Influence of Spatial Resolution in Three-dimensional Cine Phase Contrast Magnetic Resonance Imaging on the Accuracy of Hemodynamic Analysis.

    Science.gov (United States)

    Fukuyama, Atsushi; Isoda, Haruo; Morita, Kento; Mori, Marika; Watanabe, Tomoya; Ishiguro, Kenta; Komori, Yoshiaki; Kosugi, Takafumi

    2017-10-10

    We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 15, 12, 9, 6, and 3 mm). The pipes were fixed with 1% agarose containing 0.025 mol/L gadolinium contrast agent. A blood-mimicking fluid with human blood property values was circulated through the pipes at a steady flow. Magnetic resonance (MR) images (three-directional phase images with speed information and magnitude images for information of shape) were acquired using the 3-Tesla MR system and receiving coil. Temporal changes in spatially-averaged velocity and maximum velocity were calculated using hemodynamic analysis software. We calculated the error rates of the flow velocities based on the volume flow rates measured with a flowmeter and examined measurement accuracy. When the acrylic pipe was the size of the thoracicoabdominal or cervical artery and the ratio of pixel size for the pipe was set at 30% or lower, spatially-averaged velocity measurements were highly accurate. When the pixel size ratio was set at 10% or lower, maximum velocity could be measured with high accuracy. It was difficult to accurately measure maximum velocity of the 3-mm pipe, which was the size of an intracranial major artery, but the error for spatially-averaged velocity was 20% or less. Flow velocity measurement accuracy of 3D cine PC MR imaging for pipes with inner sizes equivalent to vessels in the cervical and thoracicoabdominal arteries is good. The flow velocity accuracy for the pipe with a 3-mm-diameter that is equivalent to major intracranial arteries is poor for maximum velocity, but it is relatively good for spatially-averaged velocity.

  12. Logistic regression accuracy across different spatial and temporal scales for a wide-ranging species, the marbled murrelet

    Science.gov (United States)

    Carolyn B. Meyer; Sherri L. Miller; C. John Ralph

    2004-01-01

    The scale at which habitat variables are measured affects the accuracy of resource selection functions in predicting animal use of sites. We used logistic regression models for a wide-ranging species, the marbled murrelet, (Brachyramphus marmoratus) in a large region in California to address how much changing the spatial or temporal scale of...

  13. Camera sensor arrangement for crop/weed detection accuracy in agronomic images.

    Science.gov (United States)

    Romeo, Juan; Guerrero, José Miguel; Montalvo, Martín; Emmi, Luis; Guijarro, María; Gonzalez-de-Santos, Pablo; Pajares, Gonzalo

    2013-04-02

    In Precision Agriculture, images coming from camera-based sensors are commonly used for weed identification and crop line detection, either to apply specific treatments or for vehicle guidance purposes. Accuracy of identification and detection is an important issue to be addressed in image processing. There are two main types of parameters affecting the accuracy of the images, namely: (a) extrinsic, related to the sensor's positioning in the tractor; (b) intrinsic, related to the sensor specifications, such as CCD resolution, focal length or iris aperture, among others. Moreover, in agricultural applications, the uncontrolled illumination, existing in outdoor environments, is also an important factor affecting the image accuracy. This paper is exclusively focused on two main issues, always with the goal to achieve the highest image accuracy in Precision Agriculture applications, making the following two main contributions: (a) camera sensor arrangement, to adjust extrinsic parameters and (b) design of strategies for controlling the adverse illumination effects.

  14. Estimated accuracy of classification of defects detected in welded joints by radiographic tests

    International Nuclear Information System (INIS)

    Siqueira, M.H.S.; De Silva, R.R.; De Souza, M.P.V.; Rebello, J.M.A.; Caloba, L.P.; Mery, D.

    2004-01-01

    This work is a study to estimate the accuracy of classification of the main classes of weld defects detected by radiography test, such as: undercut, lack of penetration, porosity, slag inclusion, crack or lack of fusion. To carry out this work non-linear pattern classifiers were developed, using neural networks, and the largest number of radiographic patterns as possible was used as well as statistical inference techniques of random selection of samples with and without repositioning (bootstrap) in order to estimate the accuracy of the classification. The results pointed to an estimated accuracy of around 80% for the classes of defects analyzed. (author)

  15. Estimated accuracy of classification of defects detected in welded joints by radiographic tests

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, M.H.S.; De Silva, R.R.; De Souza, M.P.V.; Rebello, J.M.A. [Federal Univ. of Rio de Janeiro, Dept., of Metallurgical and Materials Engineering, Rio de Janeiro (Brazil); Caloba, L.P. [Federal Univ. of Rio de Janeiro, Dept., of Electrical Engineering, Rio de Janeiro (Brazil); Mery, D. [Pontificia Unversidad Catolica de Chile, Escuela de Ingenieria - DCC, Dept. de Ciencia de la Computacion, Casilla, Santiago (Chile)

    2004-07-01

    This work is a study to estimate the accuracy of classification of the main classes of weld defects detected by radiography test, such as: undercut, lack of penetration, porosity, slag inclusion, crack or lack of fusion. To carry out this work non-linear pattern classifiers were developed, using neural networks, and the largest number of radiographic patterns as possible was used as well as statistical inference techniques of random selection of samples with and without repositioning (bootstrap) in order to estimate the accuracy of the classification. The results pointed to an estimated accuracy of around 80% for the classes of defects analyzed. (author)

  16. Accuracy and detection limits for bioassay measurements in radiation protection. Statistical considerations

    International Nuclear Information System (INIS)

    Brodsky, A.

    1986-04-01

    This report provides statistical concepts and formulas for defining minimum detectable amount (MDA), bias and precision of sample analytical measurements of radioactivity for radiobioassay purposes. The defined statistical quantities and accuracy criteria were developed for use in standard performance criteria for radiobioassay, but are also useful in intralaboratory quality assurance programs. This report also includes a literature review and analysis of accuracy needs and accuracy recommendations of national and international scientific organizations for radiation or radioactivity measurements used for radiation protection purposes. Computer programs are also included for calculating the probabilities of passing or failing multiple analytical tests for different acceptable ranges of bias and precision

  17. EEG channels reduction using PCA to increase XGBoost's accuracy for stroke detection

    Science.gov (United States)

    Fitriah, N.; Wijaya, S. K.; Fanany, M. I.; Badri, C.; Rezal, M.

    2017-07-01

    In Indonesia, based on the result of Basic Health Research 2013, the number of stroke patients had increased from 8.3 ‰ (2007) to 12.1 ‰ (2013). These days, some researchers are using electroencephalography (EEG) result as another option to detect the stroke disease besides CT Scan image as the gold standard. A previous study on the data of stroke and healthy patients in National Brain Center Hospital (RS PON) used Brain Symmetry Index (BSI), Delta-Alpha Ratio (DAR), and Delta-Theta-Alpha-Beta Ratio (DTABR) as the features for classification by an Extreme Learning Machine (ELM). The study got 85% accuracy with sensitivity above 86 % for acute ischemic stroke detection. Using EEG data means dealing with many data dimensions, and it can reduce the accuracy of classifier (the curse of dimensionality). Principal Component Analysis (PCA) could reduce dimensionality and computation cost without decreasing classification accuracy. XGBoost, as the scalable tree boosting classifier, can solve real-world scale problems (Higgs Boson and Allstate dataset) with using a minimal amount of resources. This paper reuses the same data from RS PON and features from previous research, preprocessed with PCA and classified with XGBoost, to increase the accuracy with fewer electrodes. The specific fewer electrodes improved the accuracy of stroke detection. Our future work will examine the other algorithm besides PCA to get higher accuracy with less number of channels.

  18. Neutron detection in the frame of spatial magnetic spin resonance

    Energy Technology Data Exchange (ETDEWEB)

    Jericha, Erwin, E-mail: jericha@ati.ac.at [TU Wien, Atominstitut, Stadionallee 2, 1020 Wien (Austria); Bosina, Joachim [TU Wien, Atominstitut, Stadionallee 2, 1020 Wien (Austria); Austrian Academy of Sciences, Stefan Meyer Institute, Boltzmanngasse 3, 1090 Wien (Austria); Institut Laue–Langevin, 71 Avenue des Martyrs, 38042 Grenoble (France); Geltenbort, Peter [Institut Laue–Langevin, 71 Avenue des Martyrs, 38042 Grenoble (France); Hino, Masahiro [Kyoto University, Research Reactor Institute, Kumatori, Osaka 590-0494 (Japan); Mach, Wilfried [TU Wien, Atominstitut, Stadionallee 2, 1020 Wien (Austria); Oda, Tatsuro [Kyoto University, Department of Nuclear Engineering, Kyoto 615-8540 (Japan); Badurek, Gerald [TU Wien, Atominstitut, Stadionallee 2, 1020 Wien (Austria)

    2017-02-11

    This work is related to neutron detection in the context of the polarised neutron optics technique of spatial magnetic spin resonance. By this technique neutron beams may be tailored in their spectral distribution and temporal structure. We have performed experiments with very cold neutrons (VCN) at the high-flux research reactor of the Institut Laue Langevin (ILL) in Grenoble to demonstrate the potential of this method. A combination of spatially and temporally resolving neutron detection allowed us to characterize a prototype neutron resonator. With this detector we were able to record neutron time-of-flight spectra, assess and minimise neutron background and provide for normalisation of the spectra owing to variations in reactor power and ambient conditions at the same time.

  19. Spatial-temporal event detection in climate parameter imagery.

    Energy Technology Data Exchange (ETDEWEB)

    McKenna, Sean Andrew; Gutierrez, Karen A.

    2011-10-01

    Previously developed techniques that comprise statistical parametric mapping, with applications focused on human brain imaging, are examined and tested here for new applications in anomaly detection within remotely-sensed imagery. Two approaches to analysis are developed: online, regression-based anomaly detection and conditional differences. These approaches are applied to two example spatial-temporal data sets: data simulated with a Gaussian field deformation approach and weekly NDVI images derived from global satellite coverage. Results indicate that anomalies can be identified in spatial temporal data with the regression-based approach. Additionally, la Nina and el Nino climatic conditions are used as different stimuli applied to the earth and this comparison shows that el Nino conditions lead to significant decreases in NDVI in both the Amazon Basin and in Southern India.

  20. Fast entanglement detection for unknown states of two spatial qutrits

    International Nuclear Information System (INIS)

    Lima, G.; Gomez, E. S.; Saavedra, C.; Vargas, A.; Vianna, R. O.

    2010-01-01

    We investigate the practicality of the method proposed by Maciel et al. [Phys. Rev. A. 80, 032325 (2009).] for detecting the entanglement of two spatial qutrits (three-dimensional quantum systems), which are encoded in the discrete transverse momentum of single photons transmitted through a multislit aperture. The method is based on the acquisition of partial information of the quantum state through projective measurements, and a data processing analysis done with semidefinite programs. This analysis relies on generating gradually an optimal entanglement witness operator, and numerical investigations have shown that it allows for the entanglement detection of unknown states with a cost much lower than full state tomography.

  1. Spatial accuracy of a simplified disaggregation method for traffic emissions applied in seven mid-sized Chilean cities

    Science.gov (United States)

    Ossés de Eicker, Margarita; Zah, Rainer; Triviño, Rubén; Hurni, Hans

    The spatial accuracy of top-down traffic emission inventory maps obtained with a simplified disaggregation method based on street density was assessed in seven mid-sized Chilean cities. Each top-down emission inventory map was compared against a reference, namely a more accurate bottom-up emission inventory map from the same study area. The comparison was carried out using a combination of numerical indicators and visual interpretation. Statistically significant differences were found between the seven cities with regard to the spatial accuracy of their top-down emission inventory maps. In compact cities with a simple street network and a single center, a good accuracy of the spatial distribution of emissions was achieved with correlation values>0.8 with respect to the bottom-up emission inventory of reference. In contrast, the simplified disaggregation method is not suitable for complex cities consisting of interconnected nuclei, resulting in correlation valuessituation to get an overview on the spatial distribution of the emissions generated by traffic activities.

  2. Detection capabilities and accuracy requirements of concentrations of radioactive material in air for radiation protection purposes

    International Nuclear Information System (INIS)

    Brodsky, A.

    1987-01-01

    Recent developments in the formulation of detection capability and accuracy criteria for bioassay measurements will be interpreted and adapted to provide similar criteria for the measurement of air concentrations of radioactive material for radiation protection purposes. Considerations of accuracy will be related to the known variability of measurement processes, as well as the uncertainties in the calculated limits of intake that serve as the basis of regulatory and voluntary standards of practice. Formulations and criteria will be presented for minimum detection amounts (MDA) and precision and bias of measurements for radiation protection purposes. 17 references

  3. The Dependence of Cloud Property Trend Detection on Absolute Calibration Accuracy of Passive Satellite Sensors

    Science.gov (United States)

    Shea, Y.; Wielicki, B. A.; Sun-Mack, S.; Minnis, P.; Zelinka, M. D.

    2016-12-01

    Detecting trends in climate variables on global, decadal scales requires highly accurate, stable measurements and retrieval algorithms. Trend uncertainty depends on its magnitude, natural variability, and instrument and retrieval algorithm accuracy and stability. We applied a climate accuracy framework to quantify the impact of absolute calibration on cloud property trend uncertainty. The cloud properties studied were cloud fraction, effective temperature, optical thickness, and effective radius retrieved using the Clouds and the Earth's Radiant Energy System (CERES) Cloud Property Retrieval System, which uses Moderate-resolution Imaging Spectroradiometer measurements (MODIS). Modeling experiments from the fifth phase of the Climate Model Intercomparison Project (CMIP5) agree that net cloud feedback is likely positive but disagree regarding its magnitude, mainly due to uncertainty in shortwave cloud feedback. With the climate accuracy framework we determined the time to detect trends for instruments with various calibration accuracies. We estimated a relationship between cloud property trend uncertainty, cloud feedback, and Equilibrium Climate Sensitivity and also between effective radius trend uncertainty and aerosol indirect effect trends. The direct relationship between instrument accuracy requirements and climate model output provides the level of instrument absolute accuracy needed to reduce climate model projection uncertainty. Different cloud types have varied radiative impacts on the climate system depending on several attributes, such as their thermodynamic phase, altitude, and optical thickness. Therefore, we also conducted these studies by cloud types for a clearer understanding of instrument accuracy requirements needed to detect changes in their cloud properties. Combining this information with the radiative impact of different cloud types helps to prioritize among requirements for future satellite sensors and understanding the climate detection

  4. Spatial heterogeneity in the Mediterranean Biodiversity Hotspot affects barcoding accuracy of its freshwater fishes.

    Science.gov (United States)

    Geiger, M F; Herder, F; Monaghan, M T; Almada, V; Barbieri, R; Bariche, M; Berrebi, P; Bohlen, J; Casal-Lopez, M; Delmastro, G B; Denys, G P J; Dettai, A; Doadrio, I; Kalogianni, E; Kärst, H; Kottelat, M; Kovačić, M; Laporte, M; Lorenzoni, M; Marčić, Z; Özuluğ, M; Perdices, A; Perea, S; Persat, H; Porcelotti, S; Puzzi, C; Robalo, J; Šanda, R; Schneider, M; Šlechtová, V; Stoumboudi, M; Walter, S; Freyhof, J

    2014-11-01

    Incomplete knowledge of biodiversity remains a stumbling block for conservation planning and even occurs within globally important Biodiversity Hotspots (BH). Although technical advances have boosted the power of molecular biodiversity assessments, the link between DNA sequences and species and the analytics to discriminate entities remain crucial. Here, we present an analysis of the first DNA barcode library for the freshwater fish fauna of the Mediterranean BH (526 spp.), with virtually complete species coverage (498 spp., 98% extant species). In order to build an identification system supporting conservation, we compared species determination by taxonomists to multiple clustering analyses of DNA barcodes for 3165 specimens. The congruence of barcode clusters with morphological determination was strongly dependent on the method of cluster delineation, but was highest with the general mixed Yule-coalescent (GMYC) model-based approach (83% of all species recovered as GMYC entity). Overall, genetic morphological discontinuities suggest the existence of up to 64 previously unrecognized candidate species. We found reduced identification accuracy when using the entire DNA-barcode database, compared with analyses on databases for individual river catchments. This scale effect has important implications for barcoding assessments and suggests that fairly simple identification pipelines provide sufficient resolution in local applications. We calculated Evolutionarily Distinct and Globally Endangered scores in order to identify candidate species for conservation priority and argue that the evolutionary content of barcode data can be used to detect priority species for future IUCN assessments. We show that large-scale barcoding inventories of complex biotas are feasible and contribute directly to the evaluation of conservation priorities. © 2014 John Wiley & Sons Ltd.

  5. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study

    International Nuclear Information System (INIS)

    Lee, In Hyouk; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub; You, Joshua H.; Lee, Ji Yong; Whang, Kum

    2010-01-01

    Although perfusion CT (PCT) for the detection of supratentorial stroke is well established, there is a dearth of evidence of its effectiveness in the detection of infratentorial stroke. Hence, this study compared sensitivity, specificity, and accuracy of PCT maps between infratentorial and supratentorial stroke lesions. One hundred patients with acute stroke who had successfully undergone near whole-brain PCT with the toggling table technique and follow-up MRI were included. Wilcoxon Mann-Whitney test was performed at P 0.01 in all PCT maps) between supratentorial and infratentorial stroke. Also, there was no remarkable difference in both sensitivity and specificity of PCT maps. This was the first study to investigate the accuracy of PCT with the toggling table technique in detection of infratentorial stroke lesions. Clinically, PCT is highly reliable and accurate in detecting infratentorial stroke lesions. (orig.)

  6. A Mobile Outdoor Augmented Reality Method Combining Deep Learning Object Detection and Spatial Relationships for Geovisualization.

    Science.gov (United States)

    Rao, Jinmeng; Qiao, Yanjun; Ren, Fu; Wang, Junxing; Du, Qingyun

    2017-08-24

    The purpose of this study was to develop a robust, fast and markerless mobile augmented reality method for registration, geovisualization and interaction in uncontrolled outdoor environments. We propose a lightweight deep-learning-based object detection approach for mobile or embedded devices; the vision-based detection results of this approach are combined with spatial relationships by means of the host device's built-in Global Positioning System receiver, Inertial Measurement Unit and magnetometer. Virtual objects generated based on geospatial information are precisely registered in the real world, and an interaction method based on touch gestures is implemented. The entire method is independent of the network to ensure robustness to poor signal conditions. A prototype system was developed and tested on the Wuhan University campus to evaluate the method and validate its results. The findings demonstrate that our method achieves a high detection accuracy, stable geovisualization results and interaction.

  7. A Mobile Outdoor Augmented Reality Method Combining Deep Learning Object Detection and Spatial Relationships for Geovisualization

    Directory of Open Access Journals (Sweden)

    Jinmeng Rao

    2017-08-01

    Full Text Available The purpose of this study was to develop a robust, fast and markerless mobile augmented reality method for registration, geovisualization and interaction in uncontrolled outdoor environments. We propose a lightweight deep-learning-based object detection approach for mobile or embedded devices; the vision-based detection results of this approach are combined with spatial relationships by means of the host device’s built-in Global Positioning System receiver, Inertial Measurement Unit and magnetometer. Virtual objects generated based on geospatial information are precisely registered in the real world, and an interaction method based on touch gestures is implemented. The entire method is independent of the network to ensure robustness to poor signal conditions. A prototype system was developed and tested on the Wuhan University campus to evaluate the method and validate its results. The findings demonstrate that our method achieves a high detection accuracy, stable geovisualization results and interaction.

  8. A Mobile Outdoor Augmented Reality Method Combining Deep Learning Object Detection and Spatial Relationships for Geovisualization

    Science.gov (United States)

    Rao, Jinmeng; Qiao, Yanjun; Ren, Fu; Wang, Junxing; Du, Qingyun

    2017-01-01

    The purpose of this study was to develop a robust, fast and markerless mobile augmented reality method for registration, geovisualization and interaction in uncontrolled outdoor environments. We propose a lightweight deep-learning-based object detection approach for mobile or embedded devices; the vision-based detection results of this approach are combined with spatial relationships by means of the host device’s built-in Global Positioning System receiver, Inertial Measurement Unit and magnetometer. Virtual objects generated based on geospatial information are precisely registered in the real world, and an interaction method based on touch gestures is implemented. The entire method is independent of the network to ensure robustness to poor signal conditions. A prototype system was developed and tested on the Wuhan University campus to evaluate the method and validate its results. The findings demonstrate that our method achieves a high detection accuracy, stable geovisualization results and interaction. PMID:28837096

  9. Thermal ionization mass spectrometry (TIMS) of actinides: Pushing the limits of accuracy and detection

    Energy Technology Data Exchange (ETDEWEB)

    Buerger, Stefan; Boulyga, Sergei; Cunningham, Alan; Klose, Dilani; Koepf, Andreas; Poths, Jane [Safeguards Analytical Laboratory, International Atomic Energy Agency, Vienna (Austria); Richter, Stephan [Institute for Reference Materials and Measurements, JRC-EU, Geel (Belgium)

    2010-07-01

    New method developments in multi-collector thermal ionization mass spectrometry (MC-TIMS) for actinide isotope ratio analysis to improve accuracy and limits of detection will be presented. With respect to limits of detection, results on improving work function using various carbon additives will be reviewed and presented as well as developments in cavity ion source (as compared to standard flat ribbon filament ion source) for femto- and attogram levels of uranium, plutonium, and americium. With respect to accuracy, results on isotope ratio measurements of isotopes of uranium (relative accuracy of 0.3% to 0.01%) are presented with an example being U-234-Th-230 age-dating (NBL CRM 112-A). In this context, the importance of traceability (to the S.I. units) and the use of (certified) reference materials are emphasized. The focus of this presentation is on applications to nuclear safeguards / forensics.

  10. d'plus: A program to calculate accuracy and bias measures from detection and discrimination data.

    Science.gov (United States)

    Macmillan, N A; Creelman, C D

    1997-01-01

    The program d'plus calculates accuracy (sensitivity) and response-bias parameters using Signal Detection Theory. Choice Theory, and 'nonparametric' models. is is appropriate for data from one-interval, two- and three-interval forced-choice, same different, ABX, and oddity experimental paradigms.

  11. Improving PET spatial resolution and detectability for prostate cancer imaging

    International Nuclear Information System (INIS)

    Bal, H; Guerin, L; Casey, M E; Conti, M; Eriksson, L; Michel, C; Fanti, S; Pettinato, C; Adler, S; Choyke, P

    2014-01-01

    Prostate cancer, one of the most common forms of cancer among men, can benefit from recent improvements in positron emission tomography (PET) technology. In particular, better spatial resolution, lower noise and higher detectability of small lesions could be greatly beneficial for early diagnosis and could provide a strong support for guiding biopsy and surgery. In this article, the impact of improved PET instrumentation with superior spatial resolution and high sensitivity are discussed, together with the latest development in PET technology: resolution recovery and time-of-flight reconstruction. Using simulated cancer lesions, inserted in clinical PET images obtained with conventional protocols, we show that visual identification of the lesions and detectability via numerical observers can already be improved using state of the art PET reconstruction methods. This was achieved using both resolution recovery and time-of-flight reconstruction, and a high resolution image with 2 mm pixel size. Channelized Hotelling numerical observers showed an increase in the area under the LROC curve from 0.52 to 0.58. In addition, a relationship between the simulated input activity and the area under the LROC curve showed that the minimum detectable activity was reduced by more than 23%. (paper)

  12. Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Notohamiprodjo, S.; Stahl, R.; Braunagel, M.; Kazmierczak, P.M.; Thierfelder, K.M.; Treitl, K.M.; Wirth, S. [University Hospital of Munich, LMU Munich, Institute for Clinical Radiology, Munich (Germany); Notohamiprodjo, M. [University Hospital Tuebingen, Eberhard Karls University Tuebingen, Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-08-15

    To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference. Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNR) of cerebrospinal fluid (CSF), annulus fibrosus (AF) and the spinal cord (SC) were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence and accuracy in the diagnosis of lumbar disc herniation using MRI as standard of reference. Inter-reader correlation was assessed with weighted κ. Sensitivity, specificity, precision and accuracy of MDCT for disc protrusion were 98.8%, 96.5%, 97.1%, 97.8% (disc level), 97.7%, 92.9%, 98.6%, 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the discs. κ (>0.90) was excellent for both algorithms. MDCT of the lumbar spine yields high diagnostic accuracy for detection of lumbar disc herniation. IR improves image quality so that the provided diagnostic accuracy is principally equivalent to MRI. (orig.)

  13. Audiovisual communication of object-names improves the spatial accuracy of recalled object-locations in topographic maps.

    Science.gov (United States)

    Lammert-Siepmann, Nils; Bestgen, Anne-Kathrin; Edler, Dennis; Kuchinke, Lars; Dickmann, Frank

    2017-01-01

    Knowing the correct location of a specific object learned from a (topographic) map is fundamental for orientation and navigation tasks. Spatial reference systems, such as coordinates or cardinal directions, are helpful tools for any geometric localization of positions that aims to be as exact as possible. Considering modern visualization techniques of multimedia cartography, map elements transferred through the auditory channel can be added easily. Audiovisual approaches have been discussed in the cartographic community for many years. However, the effectiveness of audiovisual map elements for map use has hardly been explored so far. Within an interdisciplinary (cartography-cognitive psychology) research project, it is examined whether map users remember object-locations better if they do not just read the corresponding place names, but also listen to them as voice recordings. This approach is based on the idea that learning object-identities influences learning object-locations, which is crucial for map-reading tasks. The results of an empirical study show that the additional auditory communication of object names not only improves memory for the names (object-identities), but also for the spatial accuracy of their corresponding object-locations. The audiovisual communication of semantic attribute information of a spatial object seems to improve the binding of object-identity and object-location, which enhances the spatial accuracy of object-location memory.

  14. Temporal Modulation Detection Depends on Sharpness of Spatial Tuning.

    Science.gov (United States)

    Zhou, Ning; Cadmus, Matthew; Dong, Lixue; Mathews, Juliana

    2018-04-25

    Prior research has shown that in electrical hearing, cochlear implant (CI) users' speech recognition performance is related in part to their ability to detect temporal modulation (i.e., modulation sensitivity). Previous studies have also shown better speech recognition when selectively stimulating sites with good modulation sensitivity rather than all stimulation sites. Site selection based on channel interaction measures, such as those using imaging or psychophysical estimates of spread of neural excitation, has also been shown to improve speech recognition. This led to the question of whether temporal modulation sensitivity and spatial selectivity of neural excitation are two related variables. In the present study, CI users' modulation sensitivity was compared for sites with relatively broad or narrow neural excitation patterns. This was achieved by measuring temporal modulation detection thresholds (MDTs) at stimulation sites that were significantly different in their sharpness of the psychophysical spatial tuning curves (PTCs) and measuring MDTs at the same sites in monopolar (MP) and bipolar (BP) stimulation modes. Nine postlingually deafened subjects implanted with Cochlear Nucleus® device took part in the study. Results showed a significant correlation between the sharpness of PTCs and MDTs, indicating that modulation detection benefits from a more spatially restricted neural activation pattern. There was a significant interaction between stimulation site and mode. That is, using BP stimulation only improved MDTs at stimulation sites with broad PTCs but had no effect or sometimes a detrimental effect on MDTs at stimulation sites with sharp PTCs. This interaction could suggest that a criterion number of nerve fibers is needed to achieve optimal temporal resolution, and, to achieve optimized speech recognition outcomes, individualized selection of site-specific current focusing strategies may be necessary. These results also suggest that the removal of

  15. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  16. Crosstalk elimination in the detection of dual-beam optical tweezers by spatial filtering

    International Nuclear Information System (INIS)

    Ott, Dino; Oddershede, Lene B.; Reihani, S. Nader S.

    2014-01-01

    In dual-beam optical tweezers, the accuracy of position and force measurements is often compromised by crosstalk between the two detected signals, this crosstalk leading to systematic and significant errors on the measured forces and distances. This is true both for dual-beam optical traps where the splitting of the two traps is done by polarization optics and for dual optical traps constructed by other methods, e.g., holographic tweezers. If the two traps are orthogonally polarized, most often crosstalk is minimized by inserting polarization optics in front of the detector; however, this method is not perfect because of the de-polarization of the trapping beam introduced by the required high numerical aperture optics. Here we present a simple and easy-to-implement method to efficiently eliminate crosstalk. The method is based on spatial filtering by simply inserting a pinhole at the correct position and is highly compatible with standard back focal plane photodiode based detection of position and force. Our spatial filtering method reduces crosstalk up to five times better than polarization filtering alone. The effectiveness is dependent on pinhole size and distance between the traps and is here quantified experimentally and reproduced by theoretical modeling. The method here proposed will improve the accuracy of force-distance measurements, e.g., of single molecules, performed by dual-beam optical traps and hence give much more scientific value for the experimental efforts

  17. The biophysical model for accuracy of cellular sensing spatial gradients of multiple chemoattractants

    International Nuclear Information System (INIS)

    Chang, Qiang; Zuo, Li

    2013-01-01

    Spatial gradients of surrounding chemoattractants are the key factors in determining the directionality of eukaryotic cell movement. Thus, it is important for cells to accurately measure the spatial gradients of surrounding chemoattractants. Here, we study the precision of sensing the spatial gradients of multiple chemoattractants using cooperative receptor clusters. Cooperative receptors on cells are modeled as an Ising chain of Monod–Wyman–Changeux clusters subject to multiple chemical-gradient fields to study the physical limits of multiple chemoattractants spatial gradients sensing. We found that eukaryotic cells cannot sense each chemoattractant gradient individually. Instead, cells can only sense a weighted sum of surrounding chemical gradients. Moreover, the precision of sensing one chemical gradient is signicantly affected by coexisting chemoattractant concentrations. These findings can provide a further insight into the role of chemoattractants in immune response and help develop novel treatments for inflammatory diseases. (paper)

  18. Temporal and spatial predictability of an irrelevant event differently affect detection and memory of items in a visual sequence

    Directory of Open Access Journals (Sweden)

    Junji eOhyama

    2016-02-01

    Full Text Available We examined how the temporal and spatial predictability of a task-irrelevant visual event affects the detection and memory of a visual item embedded in a continuously changing sequence. Participants observed 11 sequentially presented letters, during which a task-irrelevant visual event was either present or absent. Predictabilities of spatial location and temporal position of the event were controlled in 2 × 2 conditions. In the spatially predictable conditions, the event occurred at the same location within the stimulus sequence or at another location, while, in the spatially unpredictable conditions, it occurred at random locations. In the temporally predictable conditions, the event timing was fixed relative to the order of the letters, while in the temporally unpredictable condition, it could not be predicted from the letter order. Participants performed a working memory task and a target detection reaction time task. Memory accuracy was higher for a letter simultaneously presented at the same location as the event in the temporally unpredictable conditions, irrespective of the spatial predictability of the event. On the other hand, the detection reaction times were only faster for a letter simultaneously presented at the same location as the event when the event was both temporally and spatially predictable. Thus, to facilitate ongoing detection processes, an event must be predictable both in space and time, while memory processes are enhanced by temporally unpredictable (i.e., surprising events. Evidently, temporal predictability has differential effects on detection and memory of a visual item embedded in a sequence of images.

  19. Learning linear spatial-numeric associations improves accuracy of memory for numbers

    Directory of Open Access Journals (Sweden)

    Clarissa Ann Thompson

    2016-01-01

    Full Text Available Memory for numbers improves with age and experience. One potential source of improvement is a logarithmic-to-linear shift in children’s representations of magnitude. To test this, Kindergartners and second graders estimated the location of numbers on number lines and recalled numbers presented in vignettes (Study 1. Accuracy at number-line estimation predicted memory accuracy on a numerical recall task after controlling for the effect of age and ability to approximately order magnitudes (mapper status. To test more directly whether linear numeric magnitude representations caused improvements in memory, half of children were given feedback on their number-line estimates (Study 2. As expected, learning linear representations was again linked to memory for numerical information even after controlling for age and mapper status. These results suggest that linear representations of numerical magnitude may be a causal factor in development of numeric recall accuracy.

  20. The spatial accuracy of geographic ecological momentary assessment (GEMA): Error and bias due to subject and environmental characteristics.

    Science.gov (United States)

    Mennis, Jeremy; Mason, Michael; Ambrus, Andreea; Way, Thomas; Henry, Kevin

    2017-09-01

    Geographic ecological momentary assessment (GEMA) combines ecological momentary assessment (EMA) with global positioning systems (GPS) and geographic information systems (GIS). This study evaluates the spatial accuracy of GEMA location data and bias due to subject and environmental data characteristics. Using data for 72 subjects enrolled in a study of urban adolescent substance use, we compared the GPS-based location of EMA responses in which the subject indicated they were at home to the geocoded home address. We calculated the percentage of EMA locations within a sixteenth, eighth, quarter, and half miles from the home, and the percentage within the same tract and block group as the home. We investigated if the accuracy measures were associated with subject demographics, substance use, and emotional dysregulation, as well as environmental characteristics of the home neighborhood. Half of all subjects had more than 88% of their EMA locations within a half mile, 72% within a quarter mile, 55% within an eighth mile, 50% within a sixteenth of a mile, 83% in the correct tract, and 71% in the correct block group. There were no significant associations with subject or environmental characteristics. Results support the use of GEMA for analyzing subjects' exposures to urban environments. Researchers should be aware of the issue of spatial accuracy inherent in GEMA, and interpret results accordingly. Understanding spatial accuracy is particularly relevant for the development of 'ecological momentary interventions' (EMI), which may depend on accurate location information, though issues of privacy protection remain a concern. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Detection and removal of spatial bias in multiwell assays.

    Science.gov (United States)

    Lachmann, Alexander; Giorgi, Federico M; Alvarez, Mariano J; Califano, Andrea

    2016-07-01

    Multiplex readout assays are now increasingly being performed using microfluidic automation in multiwell format. For instance, the Library of Integrated Network-based Cellular Signatures (LINCS) has produced gene expression measurements for tens of thousands of distinct cell perturbations using a 384-well plate format. This dataset is by far the largest 384-well gene expression measurement assay ever performed. We investigated the gene expression profiles of a million samples from the LINCS dataset and found that the vast majority (96%) of the tested plates were affected by a significant 2D spatial bias. Using a novel algorithm combining spatial autocorrelation detection and principal component analysis, we could remove most of the spatial bias from the LINCS dataset and show in parallel a dramatic improvement of similarity between biological replicates assayed in different plates. The proposed methodology is fully general and can be applied to any highly multiplexed assay performed in multiwell format. ac2248@columbia.edu Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  2. Major Depression Detection from EEG Signals Using Kernel Eigen-Filter-Bank Common Spatial Patterns.

    Science.gov (United States)

    Liao, Shih-Cheng; Wu, Chien-Te; Huang, Hao-Chuan; Cheng, Wei-Teng; Liu, Yi-Hung

    2017-06-14

    Major depressive disorder (MDD) has become a leading contributor to the global burden of disease; however, there are currently no reliable biological markers or physiological measurements for efficiently and effectively dissecting the heterogeneity of MDD. Here we propose a novel method based on scalp electroencephalography (EEG) signals and a robust spectral-spatial EEG feature extractor called kernel eigen-filter-bank common spatial pattern (KEFB-CSP). The KEFB-CSP first filters the multi-channel raw EEG signals into a set of frequency sub-bands covering the range from theta to gamma bands, then spatially transforms the EEG signals of each sub-band from the original sensor space to a new space where the new signals (i.e., CSPs) are optimal for the classification between MDD and healthy controls, and finally applies the kernel principal component analysis (kernel PCA) to transform the vector containing the CSPs from all frequency sub-bands to a lower-dimensional feature vector called KEFB-CSP. Twelve patients with MDD and twelve healthy controls participated in this study, and from each participant we collected 54 resting-state EEGs of 6 s length (5 min and 24 s in total). Our results show that the proposed KEFB-CSP outperforms other EEG features including the powers of EEG frequency bands, and fractal dimension, which had been widely applied in previous EEG-based depression detection studies. The results also reveal that the 8 electrodes from the temporal areas gave higher accuracies than other scalp areas. The KEFB-CSP was able to achieve an average EEG classification accuracy of 81.23% in single-trial analysis when only the 8-electrode EEGs of the temporal area and a support vector machine (SVM) classifier were used. We also designed a voting-based leave-one-participant-out procedure to test the participant-independent individual classification accuracy. The voting-based results show that the mean classification accuracy of about 80% can be achieved by the KEFP

  3. Major Depression Detection from EEG Signals Using Kernel Eigen-Filter-Bank Common Spatial Patterns

    Directory of Open Access Journals (Sweden)

    Shih-Cheng Liao

    2017-06-01

    Full Text Available Major depressive disorder (MDD has become a leading contributor to the global burden of disease; however, there are currently no reliable biological markers or physiological measurements for efficiently and effectively dissecting the heterogeneity of MDD. Here we propose a novel method based on scalp electroencephalography (EEG signals and a robust spectral-spatial EEG feature extractor called kernel eigen-filter-bank common spatial pattern (KEFB-CSP. The KEFB-CSP first filters the multi-channel raw EEG signals into a set of frequency sub-bands covering the range from theta to gamma bands, then spatially transforms the EEG signals of each sub-band from the original sensor space to a new space where the new signals (i.e., CSPs are optimal for the classification between MDD and healthy controls, and finally applies the kernel principal component analysis (kernel PCA to transform the vector containing the CSPs from all frequency sub-bands to a lower-dimensional feature vector called KEFB-CSP. Twelve patients with MDD and twelve healthy controls participated in this study, and from each participant we collected 54 resting-state EEGs of 6 s length (5 min and 24 s in total. Our results show that the proposed KEFB-CSP outperforms other EEG features including the powers of EEG frequency bands, and fractal dimension, which had been widely applied in previous EEG-based depression detection studies. The results also reveal that the 8 electrodes from the temporal areas gave higher accuracies than other scalp areas. The KEFB-CSP was able to achieve an average EEG classification accuracy of 81.23% in single-trial analysis when only the 8-electrode EEGs of the temporal area and a support vector machine (SVM classifier were used. We also designed a voting-based leave-one-participant-out procedure to test the participant-independent individual classification accuracy. The voting-based results show that the mean classification accuracy of about 80% can be

  4. Improving Accuracy of Intrusion Detection Model Using PCA and optimized SVM

    Directory of Open Access Journals (Sweden)

    Sumaiya Thaseen Ikram

    2016-06-01

    Full Text Available Intrusion detection is very essential for providing security to different network domains and is mostly used for locating and tracing the intruders. There are many problems with traditional intrusion detection models (IDS such as low detection capability against unknown network attack, high false alarm rate and insufficient analysis capability. Hence the major scope of the research in this domain is to develop an intrusion detection model with improved accuracy and reduced training time. This paper proposes a hybrid intrusiondetection model by integrating the principal component analysis (PCA and support vector machine (SVM. The novelty of the paper is the optimization of kernel parameters of the SVM classifier using automatic parameter selection technique. This technique optimizes the punishment factor (C and kernel parameter gamma (γ, thereby improving the accuracy of the classifier and reducing the training and testing time. The experimental results obtained on the NSL KDD and gurekddcup dataset show that the proposed technique performs better with higher accuracy, faster convergence speed and better generalization. Minimum resources are consumed as the classifier input requires reduced feature set for optimum classification. A comparative analysis of hybrid models with the proposed model is also performed.

  5. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Hyouk; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub [Yonsei University, Department of Radiology, Wonju College of Medicine, Wonju (Korea, Republic of); You, Joshua H. [Center for Health, Wellness, Fitness, Prevention, and Healing Across the Life Span, Department of Physical Therapy, Graduate School of Rehabilitation Science, Yonsei University, Center for Movement Impairment Solutions, Wonju City (Korea, Republic of); Lee, Ji Yong [Yonsei University, Department of Neurology, Wonju College of Medicine, Wonju (Korea, Republic of); Whang, Kum [Yonsei University, Department of Neurosurgery, Wonju College of Medicine, Wonju (Korea, Republic of)

    2010-12-15

    Although perfusion CT (PCT) for the detection of supratentorial stroke is well established, there is a dearth of evidence of its effectiveness in the detection of infratentorial stroke. Hence, this study compared sensitivity, specificity, and accuracy of PCT maps between infratentorial and supratentorial stroke lesions. One hundred patients with acute stroke who had successfully undergone near whole-brain PCT with the toggling table technique and follow-up MRI were included. Wilcoxon Mann-Whitney test was performed at P < 0.01. There was no significant statistical difference in the accuracy (91.79% vs. 93.23% in regional cerebral blood volume; 92.26% vs. 95.31% in regional cerebral blood flow; 89.17% vs. 92.71% in mean transit time; 89.76% vs. 92.19% in time to peak; P > 0.01 in all PCT maps) between supratentorial and infratentorial stroke. Also, there was no remarkable difference in both sensitivity and specificity of PCT maps. This was the first study to investigate the accuracy of PCT with the toggling table technique in detection of infratentorial stroke lesions. Clinically, PCT is highly reliable and accurate in detecting infratentorial stroke lesions. (orig.)

  6. Spatial resolution and chest nodule detection: an interesting incidental finding

    Science.gov (United States)

    Toomey, R. J.; McEntee, M. F.; Ryan, J. T.; Evanoff, M. G.; Hayes, A.; Brennan, P. C.

    2010-02-01

    This study reports an incidental finding from a larger work. It examines the relationship between spatial resolution and nodule detection for chest radiographs. Twelve examining radiologists with the American Board of Radiology read thirty chest radiographs in two conditions - full (1500 × 1500 pixel) resolution, and 300 × 300 pixel resolution linearly interpolated to 1500 × 1500 pixels. All images were surrounded by a 10-pixel sharp grey border to aid in focussing the observer's eye when viewing the comparatively unsharp interpolated images. Fifteen of the images contained a single simulated pulmonary nodule. Observers were asked to rate their confidence that a nodule was present on each radiograph on a scale of 1 (least confidence, certain no lesion is present) to 6 (most confidence, certain a lesion was present). All other abnormalities were to be ignored. No windowing, levelling or magnification of the images was permitted and viewing distance was constrained to approximately 70cm. Images were displayed on a 3 megapixel greyscale monitor. Receiver operating characteristic (ROC) analysis was applied to the results of the readings using the Dorfman-Berbaum-Metz multiplereader, multiple-case method. No statistically significant differences were found with either readers and cases treated as random or with cases treated as fixed. Low spatial frequency information appears to be sufficient for the detection of chest lesion of the type used in this study.

  7. Advancing the speed, sensitivity and accuracy of biomolecular detection using multi-length-scale engineering

    Science.gov (United States)

    Kelley, Shana O.; Mirkin, Chad A.; Walt, David R.; Ismagilov, Rustem F.; Toner, Mehmet; Sargent, Edward H.

    2014-12-01

    Rapid progress in identifying disease biomarkers has increased the importance of creating high-performance detection technologies. Over the last decade, the design of many detection platforms has focused on either the nano or micro length scale. Here, we review recent strategies that combine nano- and microscale materials and devices to produce large improvements in detection sensitivity, speed and accuracy, allowing previously undetectable biomarkers to be identified in clinical samples. Microsensors that incorporate nanoscale features can now rapidly detect disease-related nucleic acids expressed in patient samples. New microdevices that separate large clinical samples into nanocompartments allow precise quantitation of analytes, and microfluidic systems that utilize nanoscale binding events can detect rare cancer cells in the bloodstream more accurately than before. These advances will lead to faster and more reliable clinical diagnostic devices.

  8. An Examination of Three Spatial Event Cluster Detection Methods

    Directory of Open Access Journals (Sweden)

    Hensley H. Mariathas

    2015-03-01

    Full Text Available In spatial disease surveillance, geographic areas with large numbers of disease cases are to be identified, so that targeted investigations can be pursued. Geographic areas with high disease rates are called disease clusters and statistical cluster detection tests are used to identify geographic areas with higher disease rates than expected by chance alone. In some situations, disease-related events rather than individuals are of interest for geographical surveillance, and methods to detect clusters of disease-related events are called event cluster detection methods. In this paper, we examine three distributional assumptions for the events in cluster detection: compound Poisson, approximate normal and multiple hypergeometric (exact. The methods differ on the choice of distributional assumption for the potentially multiple correlated events per individual. The methods are illustrated on emergency department (ED presentations by children and youth (age < 18 years because of substance use in the province of Alberta, Canada, during 1 April 2007, to 31 March 2008. Simulation studies are conducted to investigate Type I error and the power of the clustering methods.

  9. Spatial statistical analysis of organs for intelligent CAD and its application to disease detection

    International Nuclear Information System (INIS)

    Takizawa, Hotaka

    2009-01-01

    The present article reports our research that was performed in a research project supported by a Grantin-Aid for Scientific Research on Priority Area from the Ministry of Education, Culture Sports, Science and Technology, JAPAN, from 2003 to 2006. Our method developed in the research acquired the trend of variation of spatial relations between true diseases, false positives and image features through statistical analysis of a set of medical images and improved the accuracy of disease detection by predicting their occurrence positions in an image based on the trend. This article describes the formulation of the method in general form and shows the results obtained by applying the method to chest X-ray CT images for detection of pulmonary nodules. (author)

  10. Speed-accuracy trade-offs in computing spatial impulse responses for simulating medical ultrasound imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2001-01-01

    sampling frequency is unnecessary in the final signals, since the transducers used in medical ultrasound are band limited. Approaches to reduce the sampling frequency are, thus, needed to make efficient simulation programs. Field II uses time integration of the spatial impulse responses using a continuous......Medical ultrasound imaging can be simulated realistically using linear acoustics. One of the most powerful approaches is to employ spatial impulse responses. Hereby both emitted fields and pulse-echo responses from point scatterers can be determined. Also any kind of dynamic focusing...

  11. Study on Classification Accuracy Inspection of Land Cover Data Aided by Automatic Image Change Detection Technology

    Science.gov (United States)

    Xie, W.-J.; Zhang, L.; Chen, H.-P.; Zhou, J.; Mao, W.-J.

    2018-04-01

    The purpose of carrying out national geographic conditions monitoring is to obtain information of surface changes caused by human social and economic activities, so that the geographic information can be used to offer better services for the government, enterprise and public. Land cover data contains detailed geographic conditions information, thus has been listed as one of the important achievements in the national geographic conditions monitoring project. At present, the main issue of the production of the land cover data is about how to improve the classification accuracy. For the land cover data quality inspection and acceptance, classification accuracy is also an important check point. So far, the classification accuracy inspection is mainly based on human-computer interaction or manual inspection in the project, which are time consuming and laborious. By harnessing the automatic high-resolution remote sensing image change detection technology based on the ERDAS IMAGINE platform, this paper carried out the classification accuracy inspection test of land cover data in the project, and presented a corresponding technical route, which includes data pre-processing, change detection, result output and information extraction. The result of the quality inspection test shows the effectiveness of the technical route, which can meet the inspection needs for the two typical errors, that is, missing and incorrect update error, and effectively reduces the work intensity of human-computer interaction inspection for quality inspectors, and also provides a technical reference for the data production and quality control of the land cover data.

  12. Detection accuracy of in vitro approximal caries by cone beam computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Qu Xingmin, E-mail: quxingmin@bjmu.edu.cn [Department of Oral and Maxillofacial Radiology, Peking University School and Hospital of Stomatology, 22 Zhongguancun Nandajie, Hai Dian District, Beijing 100081 (China); Li Gang, E-mail: kqgang@bjmu.edu.cn [Department of Oral and Maxillofacial Radiology, Peking University School and Hospital of Stomatology, 22 Zhongguancun Nandajie, Hai Dian District, Beijing 100081 (China); Zhang Zuyan, E-mail: zhangzy-bj@vip.sina.com [Department of Oral and Maxillofacial Radiology, Peking University School and Hospital of Stomatology, 22 Zhongguancun Nandajie, Hai Dian District, Beijing 100081 (China); Ma Xuchen, E-mail: kqxcma@bjmu.edu.cn [Department of Oral and Maxillofacial Radiology, Peking University School and Hospital of Stomatology, 22 Zhongguancun Nandajie, Hai Dian District, Beijing 100081 (China)

    2011-08-15

    Aims: To evaluate the diagnostic accuracy of approximal carious lesions among five CBCT systems and to assess the effect of detector types employed by different CBCT systems on the accuracy of approximal caries diagnosis. Materials and methods: Thirty-nine extracted non-cavitated human permanent teeth were employed in the study. Seven observers evaluated 78 approximal surfaces of the teeth with respect to caries by the images from the following five CBCT systems: (1) NewTom 9000; (2) Accuitomo 3DX; (3) Kodak 9000 3D; (4) ProMax 3D; and (5) DCT PRO, respectively. The lesions were validated by histological examination. The area under receiver operating characteristic (ROC) curve (A{sub z}) was used to evaluate the diagnostic accuracy. Results: Microscopy of approximal surfaces found 47.4% sound, 39.8% enamel and 12.8% dentin lesions. The differences of A{sub z} values among the five CBCT systems were not statistically significant (p = 0.348). No significant difference was found between the two detector types of CBCT systems (p = 0.47). Conclusions: The five CBCT systems employed in the study showed no significant difference in the in vitro approximal caries detection. Neither the detector nor the FOV employed by the CBCT systems has an impact on the detection accuracy of approximal caries.

  13. Detection accuracy of in vitro approximal caries by cone beam computed tomography images

    International Nuclear Information System (INIS)

    Qu Xingmin; Li Gang; Zhang Zuyan; Ma Xuchen

    2011-01-01

    Aims: To evaluate the diagnostic accuracy of approximal carious lesions among five CBCT systems and to assess the effect of detector types employed by different CBCT systems on the accuracy of approximal caries diagnosis. Materials and methods: Thirty-nine extracted non-cavitated human permanent teeth were employed in the study. Seven observers evaluated 78 approximal surfaces of the teeth with respect to caries by the images from the following five CBCT systems: (1) NewTom 9000; (2) Accuitomo 3DX; (3) Kodak 9000 3D; (4) ProMax 3D; and (5) DCT PRO, respectively. The lesions were validated by histological examination. The area under receiver operating characteristic (ROC) curve (A z ) was used to evaluate the diagnostic accuracy. Results: Microscopy of approximal surfaces found 47.4% sound, 39.8% enamel and 12.8% dentin lesions. The differences of A z values among the five CBCT systems were not statistically significant (p = 0.348). No significant difference was found between the two detector types of CBCT systems (p = 0.47). Conclusions: The five CBCT systems employed in the study showed no significant difference in the in vitro approximal caries detection. Neither the detector nor the FOV employed by the CBCT systems has an impact on the detection accuracy of approximal caries.

  14. Improving supervised classification accuracy using non-rigid multimodal image registration: detecting prostate cancer

    Science.gov (United States)

    Chappelow, Jonathan; Viswanath, Satish; Monaco, James; Rosen, Mark; Tomaszewski, John; Feldman, Michael; Madabhushi, Anant

    2008-03-01

    Computer-aided diagnosis (CAD) systems for the detection of cancer in medical images require precise labeling of training data. For magnetic resonance (MR) imaging (MRI) of the prostate, training labels define the spatial extent of prostate cancer (CaP); the most common source for these labels is expert segmentations. When ancillary data such as whole mount histology (WMH) sections, which provide the gold standard for cancer ground truth, are available, the manual labeling of CaP can be improved by referencing WMH. However, manual segmentation is error prone, time consuming and not reproducible. Therefore, we present the use of multimodal image registration to automatically and accurately transcribe CaP from histology onto MRI following alignment of the two modalities, in order to improve the quality of training data and hence classifier performance. We quantitatively demonstrate the superiority of this registration-based methodology by comparing its results to the manual CaP annotation of expert radiologists. Five supervised CAD classifiers were trained using the labels for CaP extent on MRI obtained by the expert and 4 different registration techniques. Two of the registration methods were affi;ne schemes; one based on maximization of mutual information (MI) and the other method that we previously developed, Combined Feature Ensemble Mutual Information (COFEMI), which incorporates high-order statistical features for robust multimodal registration. Two non-rigid schemes were obtained by succeeding the two affine registration methods with an elastic deformation step using thin-plate splines (TPS). In the absence of definitive ground truth for CaP extent on MRI, classifier accuracy was evaluated against 7 ground truth surrogates obtained by different combinations of the expert and registration segmentations. For 26 multimodal MRI-WMH image pairs, all four registration methods produced a higher area under the receiver operating characteristic curve compared to that

  15. Pro-active data breach detection: examining accuracy and applicability on personal information detected

    CSIR Research Space (South Africa)

    Botha, J

    2016-03-01

    Full Text Available breaches but does not provide a clear indication of the level of personal information available on the internet since only reported incidents are taken into account. The possibility of pro-active automated breach detection has previously been discussed as a...

  16. Accuracy of spirometry for detection of asthma: a cross-sectional study.

    Science.gov (United States)

    Meneghini, Andréa Cristina; Paulino, Ana Carolina Botto; Pereira, Luciano Penha; Vianna, Elcio Oliveira

    2017-01-01

    Asthma is a chronic inflammatory disease with airway hyperresponsiveness. Spirometry is the most commonly used test among asthmatic patients. Another functional test used for diagnosing asthma is the bronchial challenge test. The aim of this study was to analyze the accuracy of spirometry for detecting asthma in the general population. Cross-sectional study with data analysis to evaluate the accuracy of spirometry through calculating sensitivity, specificity and predictive values and through the kappa agreement test. Subjects who constituted a birth cohort were enrolled at the age of 23 to 25 years. Spirometric abnormality was defined as reduced forced expiratory volume in one second, i.e. lower than 80% of the predicted value. Measurement of bronchial responsiveness was performed by means of the bronchial challenge test with methacholine. The gold-standard diagnosis of asthma was defined as the presence of bronchial hyperresponsiveness in association with respiratory symptoms. Asthma was detected in 200 subjects (10.4%) out of the sample of 1922 individuals. Spirometric abnormality was detected in 208 subjects (10.9%) of the sample. The specificity of spirometric abnormality for detecting asthma was 90%, sensitivity was 23%, positive predictive value was 22%, and negative predictive value was 91%. The kappa test revealed weak agreement of 0.13 (95% confidence interval, CI: 0.07-0.19) between spirometry and the diagnosis of asthma. Spirometry, as a single test, has limitations for detecting asthma in the general population.

  17. Accessibility versus accuracy in retrieving spatial memory: evidence for suboptimal assumed headings.

    Science.gov (United States)

    Yerramsetti, Ashok; Marchette, Steven A; Shelton, Amy L

    2013-07-01

    Orientation dependence in spatial memory has often been interpreted in terms of accessibility: Object locations are encoded relative to a reference orientation that affords the most accurate access to spatial memory. An open question, however, is whether people naturally use this "preferred" orientation whenever recalling the space. We tested this question by asking participants to locate buildings on a familiar campus from various imagined locations, without specifying the heading to be assumed. We then used these pointing judgments to infer the approximate heading participants assumed at each location. Surprisingly, each location showed a unique assumed heading that was consistent across participants and seemed to reflect episodic or visual properties of the space. This result suggests that although locations are encoded relative to a reference orientation, other factors may influence how people choose to access the stored information and whether they appeal to long-term spatial memory or other more sensory-based stores. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  18. Accuracy in mineral identification: image spectral and spatial resolutions and mineral spectral properties

    Directory of Open Access Journals (Sweden)

    L. Pompilio

    2006-06-01

    Full Text Available Problems related to airborne hyperspectral image data are reviewed and the requirements for data analysis applied to mineralogical (rocks and soils interpretation are discussed. The variability of mineral spectral features, including absorption position, shape and depth is considered and interpreted as due to chemical composition, grain size effects and mineral association. It is also shown how this variability can be related to well defined geologic processes. The influence of sensor noise and diffuse atmospheric radiance in classification accuracy is also analyzed.

  19. Amplitude Integrated Electroencephalography Compared With Conventional Video EEG for Neonatal Seizure Detection: A Diagnostic Accuracy Study.

    Science.gov (United States)

    Rakshasbhuvankar, Abhijeet; Rao, Shripada; Palumbo, Linda; Ghosh, Soumya; Nagarajan, Lakshmi

    2017-08-01

    This diagnostic accuracy study compared the accuracy of seizure detection by amplitude-integrated electroencephalography with the criterion standard conventional video EEG in term and near-term infants at risk of seizures. Simultaneous recording of amplitude-integrated EEG (2-channel amplitude-integrated EEG with raw trace) and video EEG was done for 24 hours for each infant. Amplitude-integrated EEG was interpreted by a neonatologist; video EEG was interpreted by a neurologist independently. Thirty-five infants were included in the analysis. In the 7 infants with seizures on video EEG, there were 169 seizure episodes on video EEG, of which only 57 were identified by amplitude-integrated EEG. Amplitude-integrated EEG had a sensitivity of 33.7% for individual seizure detection. Amplitude-integrated EEG had an 86% sensitivity for detection of babies with seizures; however, it was nonspecific, in that 50% of infants with seizures detected by amplitude-integrated EEG did not have true seizures by video EEG. In conclusion, our study suggests that amplitude-integrated EEG is a poor screening tool for neonatal seizures.

  20. Improving Accuracy of Dempster-Shafer Theory Based Anomaly Detection Systems

    Directory of Open Access Journals (Sweden)

    Ling Zou

    2014-07-01

    Full Text Available While the Dempster-Shafer theory of evidence has been widely used in anomaly detection, there are some issues with them. Dempster-Shafer theory of evidence trusts evidences equally which does not hold in distributed-sensor ADS. Moreover, evidences are dependent with each other sometimes which will lead to false alert. We propose improving by incorporating two algorithms. Features selection algorithm employs Gaussian Graphical Models to discover correlation between some candidate features. A group of suitable ADS were selected to detect and detection result were send to the fusion engine. Information gain is applied to set weight for every feature on Weights estimated algorithm. A weighted Dempster-Shafer theory of evidence combined the detection results to achieve a better accuracy. We evaluate our detection prototype through a set of experiments that were conducted with standard benchmark Wisconsin Breast Cancer Dataset and real Internet traffic. Evaluations on the Wisconsin Breast Cancer Dataset show that our prototype can find the correlation in nine features and improve the detection rate without affecting the false positive rate. Evaluations on Internet traffic show that Weights estimated algorithm can improve the detection performance significantly.

  1. Assessing the accuracy of TDR-based water leak detection system

    Science.gov (United States)

    Fatemi Aghda, S. M.; GanjaliPour, K.; Nabiollahi, K.

    2018-03-01

    The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years. In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases. The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points) showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points.

  2. Assessing the accuracy of TDR-based water leak detection system

    Directory of Open Access Journals (Sweden)

    S.M. Fatemi Aghda

    2018-03-01

    Full Text Available The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years.In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases.The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points. Keywords: Multiple leakage points, TDR, Reference points

  3. Simultaneous detection of landmarks and key-frame in cardiac perfusion MRI using a joint spatial-temporal context model

    Science.gov (United States)

    Lu, Xiaoguang; Xue, Hui; Jolly, Marie-Pierre; Guetter, Christoph; Kellman, Peter; Hsu, Li-Yueh; Arai, Andrew; Zuehlsdorff, Sven; Littmann, Arne; Georgescu, Bogdan; Guehring, Jens

    2011-03-01

    Cardiac perfusion magnetic resonance imaging (MRI) has proven clinical significance in diagnosis of heart diseases. However, analysis of perfusion data is time-consuming, where automatic detection of anatomic landmarks and key-frames from perfusion MR sequences is helpful for anchoring structures and functional analysis of the heart, leading toward fully automated perfusion analysis. Learning-based object detection methods have demonstrated their capabilities to handle large variations of the object by exploring a local region, i.e., context. Conventional 2D approaches take into account spatial context only. Temporal signals in perfusion data present a strong cue for anchoring. We propose a joint context model to encode both spatial and temporal evidence. In addition, our spatial context is constructed not only based on the landmark of interest, but also the landmarks that are correlated in the neighboring anatomies. A discriminative model is learned through a probabilistic boosting tree. A marginal space learning strategy is applied to efficiently learn and search in a high dimensional parameter space. A fully automatic system is developed to simultaneously detect anatomic landmarks and key frames in both RV and LV from perfusion sequences. The proposed approach was evaluated on a database of 373 cardiac perfusion MRI sequences from 77 patients. Experimental results of a 4-fold cross validation show superior landmark detection accuracies of the proposed joint spatial-temporal approach to the 2D approach that is based on spatial context only. The key-frame identification results are promising.

  4. INFLUENCE OF THE SPATIAL ARRANGEMENT OF SEISMIC DETECTORS ON THE ACCURACY OF EARTHQUAKE HYPOCENTRE DETERMINATION

    Directory of Open Access Journals (Sweden)

    T. G. Aslanov

    2016-01-01

    Full Text Available Objectives. To determine the coordinates of the seismic focus of an earthquake with a minimum margin of error with the use of an optimal selection of seismic sensors. Method. Seismic wave velocity data, relying on the time discrepancies between the registering of seismic waves on the seismic sensor and the defined error in determining the time difference, were used to identify errors in the location of an earthquake's hypocenter depending on the respective positions of three seismic sensors. Discrepancies between data containing an error and those without it used to determine two hypocenters provide information about the hypocenter locating error. An analysis of the influence of the respective arrangements of the seismic sensors and the earthquake epicentre on the accuracy of determination of epicentre coordinates was carried out. Results. It is established that, in order to improve the accuracy of epicenter and hypocenter earthquake coordinate determination, it is preferable to use different combinations of seismic sensors. The present recommendations are based on the desire to reduce errors in determining the earthquake source coordinates. Due to earthquake epicenter distance determination errors found in different seismic sensors both with increasing and decreasing distance, the hypocenter coordinate determining error has been found to depend on the respective arrangement of seismic sensors and on the earthquake source's geographical location. In order to determine the dependence of the source coordinate determining error on the relative position of three seismic sensors, the third seismic sensor was displaced on a horizontal plane at the location centered at the coordinate of the origin. Conclusion. When selecting seismic sensors it is essential that one of them be located perpendicular to the center of the segment formed by the other two seismic sensors. The probability of a multidirectional error of measurement at the moment of arrival of

  5. Analysis of Alabama Airborne Gravity at Three Altitudes: Expected Accuracy and Spatial Resolution from a Future Tibetan Airborne Gravity Survey

    Directory of Open Access Journals (Sweden)

    Chi-Hsun Huang

    2013-01-01

    Full Text Available In situ airborne gravity data at altitudes of 11, 6.3, and 1.7 km over a smooth area of Alabama are used to assess gravity accuracy and errors in upward and downward continuations. Analysis of the Alabama free-air anomaly gravity data at crossover points at the three altitudes suggests 1 - 2 mgal accuracy for the dataset. Gravity data at each altitude are then expanded into local 3D Fourier series, to prepare for continuation. This Fourier representation results in continuation errors at few-mgal level in Alabama, even in the extreme case of downward continuation from 11 km to sea level. The result in Alabama inspires an airborne gravity survey over the rough, inaccessible terrain of Tibet. Similar investigations as in Alabama are made in Tibet using EGM08-derived airborne gravity data at flight altitudes of 10, 5, and 0 km. Bouguer anomalies at the 10-km altitude preserve the major tectonic features of Tibet. Downward continuation errors increase with terrain roughness, but the survey can enhance local tectonic features. This study highlights the value of a future Tibetan airborne gravity survey and points out the expected gravity accuracy and spatial resolution from this survey.

  6. Clock Drawing in Spatial Neglect: A Comprehensive Analysis of Clock Perimeter, Placement, and Accuracy

    Science.gov (United States)

    Chen, Peii; Goedert, Kelly M.

    2012-01-01

    Clock drawings produced by right-brain-damaged (RBD) individuals with spatial neglect often contain an abundance of empty space on the left while numbers and hands are placed on the right. However, the clock perimeter is rarely compromised in neglect patients’ drawings. By analyzing clock drawings produced by 71 RBD and 40 healthy adults, this study investigated whether the geometric characteristics of the clock perimeter reveal novel insights to understanding spatial neglect. Neglect participants drew smaller clocks than either healthy or non-neglect RBD participants. While healthy participants’ clock perimeter was close to circular, RBD participants drew radially extended ellipses. The mechanisms for these phenomena were investigated by examining the relation between clock-drawing characteristics and performance on six subtests of the Behavioral Inattention Test (BIT). The findings indicated that the clock shape was independent of any BIT subtest or the drawing placement on the test sheet and that the clock size was significantly predicted by one BIT subtest: the poorer the figure and shape copying, the smaller the clock perimeter. Further analyses revealed that in all participants, clocks decreased in size as they were placed farther from the center of the paper. However, even when neglect participants placed their clocks towards the center of the page, they were smaller than those produced by healthy or non-neglect RBD participants. These results suggest a neglect-specific reduction in the subjectively available workspace for graphic production from memory, consistent with the hypothesis that neglect patients are impaired in the ability to enlarge the attentional aperture. PMID:22390278

  7. Accuracy of Daily Lung Ultrasound for the Detection of Pulmonary Edema Following Subarachnoid Hemorrhage.

    Science.gov (United States)

    Williamson, Craig A; Co, Ivan; Pandey, Aditya S; Gregory Thompson, B; Rajajee, Venkatakrishna

    2016-04-01

    Early detection of pulmonary edema is vital to appropriate fluid management following subarachnoid hemorrhage (SAH). Lung ultrasound (LUS) has been shown to accurately identify pulmonary edema in patients with acute respiratory failure (ARF). Our objective was to determine the accuracy of daily screening LUS for the detection of pulmonary edema following SAH. Screening LUS was performed in conjunction with daily transcranial doppler for SAH patients within the delayed cerebral ischemia (DCI) risk period in our neuroICU. We reviewed records of SAH patients admitted 7/2012-5/2014 who underwent bilateral LUS on at least 5 consecutive days. Ultrasound videos were reviewed by an investigator blinded to the final diagnosis. "B+ lines" were defined as ≥3 B-lines on LUS. Two other investigators blinded to ultrasound results determined whether pulmonary edema with ARF (PE-ARF) was present during the period of evaluation on the basis of independent chart review, with a fourth investigator performing adjudication in the event of disagreement. The diagnostic accuracy of B+ lines for the detection of PE-ARF and RPE was determined. Of 59 patients meeting criteria for inclusion, 21 (36%) had PE-ARF and 26 (44%) had B+ lines. Kappa for inter-rater agreement was 0.821 (p pulmonary edema following SAH and may assist with fluid titration during the risk period for DCI.

  8. No special K! A signal detection framework for the strategic regulation of memory accuracy.

    Science.gov (United States)

    Higham, Philip A

    2007-02-01

    Two experiments investigated criterion setting and metacognitive processes underlying the strategic regulation of accuracy on the Scholastic Aptitude Test (SAT) using Type-2 signal detection theory (SDT). In Experiment 1, report bias was manipulated by penalizing participants either 0.25 (low incentive) or 4 (high incentive) points for each error. Best guesses to unanswered items were obtained so that Type-2 signal detection indices of discrimination and bias could be calculated. The same incentive manipulation was used in Experiment 2, only the test was computerized, confidence ratings were taken so that receiver operating characteristic (ROC) curves could be generated, and feedback was manipulated. The results of both experiments demonstrated that SDT provides a viable alternative to A. Koriat and M. Goldsmith's (1996c) framework of monitoring and control and reveals information about the regulation of accuracy that their framework does not. For example, ROC analysis indicated that the threshold model implied by formula scoring is inadequate. Instead, performance on the SAT should be modeled with an equal-variance Gaussian, Type-2 signal detection model. ((c) 2007 APA, all rights reserved).

  9. EBSD spatial resolution for detecting sigma phase in steels

    Energy Technology Data Exchange (ETDEWEB)

    Bordín, S. Fernandez; Limandri, S. [Instituto de Física Enrique Gaviola, CONICET. M. Allende s/n, Ciudad Universitaria, 5000 Córdoba (Argentina); Ranalli, J.M. [Comisión Nacional de Energía Atómica, Av. Gral. Paz 1499, San Martín, 1650 Buenos Aires (Argentina); Castellano, G. [Instituto de Física Enrique Gaviola, CONICET. M. Allende s/n, Ciudad Universitaria, 5000 Córdoba (Argentina)

    2016-12-15

    The spatial resolution of the electron backscatter diffraction signal is explored by Monte Carlo simulation for the sigma phase in steel at a typical instrumental set-up. In order to estimate the active volume corresponding to the diffracted electrons, the fraction of the backscattered electrons contributing to the diffraction signal was inferred by extrapolating the Kikuchi pattern contrast measured by other authors, as a function of the diffracted electron energy. In the resulting estimation, the contribution of the intrinsic incident beam size and the software capability to deconvolve patterns were included. A strong influence of the beam size on the lateral resolution was observed, resulting in 20 nm for the aperture considered. For longitudinal and depth directions the resolutions obtained were 75 nm and 16 nm, respectively. The reliability of this last result is discussed in terms of the survey of the last large-angle deflection undergone by the backscattered electrons involved in the diffraction process. Bearing in mind the mean transversal resolution found, it was possible to detect small area grains of sigma phase by EBSD measurements, for a stabilized austenitic AISI 347 stainless steel under heat treatments, simulating post welding (40 h at 600 °C) and aging (284 h at 484 °C) effects—as usually occurring in nuclear reactor pressure vessels. - Highlights: • EBSD spatial resolution is studied by Monte Carlo simulation for σ-phase in steel. • The contribution of the intrinsic incident beam size was included. • A stabilized austenitic stainless steel under heat treatments was measured by EBSD. • With the transversal resolution found, small area σ-phase grains could be identified.

  10. Stopping power accuracy and achievable spatial resolution of helium ion imaging using a prototype particle CT detector system

    Directory of Open Access Journals (Sweden)

    Volz Lennart

    2017-09-01

    Full Text Available A precise relative stopping power map of the patient is crucial for accurate particle therapy. Charged particle imaging determines the stopping power either tomographically – particle computed tomography (pCT – or by combining prior knowledge from particle radiography (pRad and x-ray CT. Generally, multiple Coulomb scattering limits the spatial resolution. Compared to protons, heavier particles scatter less due to their lower charge/mass ratio. A theoretical framework to predict the most likely trajectory of particles in matter was developed for light ions up to carbon and was found to be the most accurate for helium comparing for fixed initial velocity. To further investigate the potential of helium in particle imaging, helium computed tomography (HeCT and radiography (HeRad were studied at the Heidel-berg Ion-Beam Therapy Centre (HIT using a prototype pCT detector system registering individual particles, originally developed by the U.S. pCT collaboration. Several phantoms were investigated: modules of the Catphan QA phantom for analysis of spatial resolution and achievable stopping power accuracy, a paediatric head phantom (CIRS and a custom-made phantom comprised of animal meat enclosed in a 2 % agarose mixture representing human tissue. The pCT images were reconstructed applying the CARP iterative reconstruction algorithm. The MTF10% was investigated using a sharp edge gradient technique. HeRad provides a spatial resolution above that of protons (MTF1010%=6.07 lp/cm for HeRad versus MTF10%=3.35 lp/cm for proton radiography. For HeCT, the spatial resolution was limited by the number of projections acquired (90 projections for a full scan. The RSP accuracy for all inserts of the Catphan CTP404 module was found to be 2.5% or better and is subject to further optimisation. In conclusion, helium imaging appears to offer higher spatial resolution compared to proton imaging. In future studies, the advantage of helium imaging compared to other

  11. Single-trial detection of visual evoked potentials by common spatial patterns and wavelet filtering for brain-computer interface.

    Science.gov (United States)

    Tu, Yiheng; Huang, Gan; Hung, Yeung Sam; Hu, Li; Hu, Yong; Zhang, Zhiguo

    2013-01-01

    Event-related potentials (ERPs) are widely used in brain-computer interface (BCI) systems as input signals conveying a subject's intention. A fast and reliable single-trial ERP detection method can be used to develop a BCI system with both high speed and high accuracy. However, most of single-trial ERP detection methods are developed for offline EEG analysis and thus have a high computational complexity and need manual operations. Therefore, they are not applicable to practical BCI systems, which require a low-complexity and automatic ERP detection method. This work presents a joint spatial-time-frequency filter that combines common spatial patterns (CSP) and wavelet filtering (WF) for improving the signal-to-noise (SNR) of visual evoked potentials (VEP), which can lead to a single-trial ERP-based BCI.

  12. Single photon detection and localization accuracy with an ebCMOS camera

    Energy Technology Data Exchange (ETDEWEB)

    Cajgfinger, T. [CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622 (France); Dominjon, A., E-mail: agnes.dominjon@nao.ac.jp [Université de Lyon, Université de Lyon 1, Lyon 69003 France. (France); Barbier, R. [CNRS/IN2P3, Institut de Physique Nucléaire de Lyon, Villeurbanne F-69622 (France); Université de Lyon, Université de Lyon 1, Lyon 69003 France. (France)

    2015-07-01

    The CMOS sensor technologies evolve very fast and offer today very promising solutions to existing issues facing by imaging camera systems. CMOS sensors are very attractive for fast and sensitive imaging thanks to their low pixel noise (1e-) and their possibility of backside illumination. The ebCMOS group of IPNL has produced a camera system dedicated to Low Light Level detection and based on a 640 kPixels ebCMOS with its acquisition system. After reminding the principle of detection of an ebCMOS and the characteristics of our prototype, we confront our camera to other imaging systems. We compare the identification efficiency and the localization accuracy of a point source by four different photo-detection devices: the scientific CMOS (sCMOS), the Charge Coupled Device (CDD), the Electron Multiplying CCD (emCCD) and the Electron Bombarded CMOS (ebCMOS). Our ebCMOS camera is able to identify a single photon source in less than 10 ms with a localization accuracy better than 1 µm. We report as well efficiency measurement and the false positive identification of the ebCMOS camera by identifying more than hundreds of single photon sources in parallel. About 700 spots are identified with a detection efficiency higher than 90% and a false positive percentage lower than 5. With these measurements, we show that our target tracking algorithm can be implemented in real time at 500 frames per second under a photon flux of the order of 8000 photons per frame. These results demonstrate that the ebCMOS camera concept with its single photon detection and target tracking algorithm is one of the best devices for low light and fast applications such as bioluminescence imaging, quantum dots tracking or adaptive optics.

  13. Spatial accuracy of 3D reconstructed radioluminographs of serial tissue sections and resultant absorbed dose estimates

    Energy Technology Data Exchange (ETDEWEB)

    Petrie, I.A.; Flynn, A.A.; Pedley, R.B.; Green, A.J.; El-Emir, E.; Dearling, J.L.J.; Boxer, G.M.; Boden, R.; Begent, R.H.J. [Cancer Research UK Targeting and Imaging Group, Department of Oncology, Royal Free and University College Medical School, Royal Free Campus, London (United Kingdom)

    2002-10-21

    Many agents using tumour-associated characteristics are deposited heterogeneously within tumour tissue. Consequently, tumour heterogeneity should be addressed when obtaining information on tumour biology or relating absorbed radiation dose to biological effect. We present a technique that enables radioluminographs of serial tumour sections to be reconstructed using automated computerized techniques, resulting in a three-dimensional map of the dose-rate distribution of a radiolabelled antibody. The purpose of this study is to assess the reconstruction accuracy. Furthermore, we estimate the potential error resulting from registration misalignment, for a range of beta-emitting radionuclides. We compare the actual dose-rate distribution with that obtained from the same activity distribution but with manually defined translational and rotational shifts. As expected, the error produced with the short-range {sup 14}C is much larger than that for the longer range {sup 90}Y; similarly values for the medium range {sup 131}I are between the two. Thus, the impact of registration inaccuracies is greater for short-range sources. (author)

  14. The diagnostic accuracy of carcinoembryonic antigen to detect colorectal cancer recurrence – A systematic review

    DEFF Research Database (Denmark)

    Sørensen, Caspar G; Karlsson, William K; Pommergaard, Hans-Christian

    2016-01-01

    INTRODUCTION: Carcinoembryonic Antigen (CEA) has been used as a tumor marker in the follow-up of colorectal cancer for more than 40 years. Controversy exists regarding its diagnostic applicability due to a relatively low sensitivity and a questionable effect on mortality. The aim of this review...... was to assess the diagnostic accuracy of CEA in detecting recurrence after intended curative surgery for primary colorectal cancer. METHODS: Systematic literature searches were performed in PubMed, EMBASE and Cochrane databases, and articles were chosen based on predefined inclusion criteria. Reference lists...

  15. Accuracy of ultrasonography in the detection of severe hepatic lipidosis in cats.

    Science.gov (United States)

    Yeager, A E; Mohammed, H

    1992-04-01

    The accuracy of ultrasonography in detection of feline hepatic lipidosis was studied retrospectively. The following ultrasonographic criteria were associated positively with severe hepatic lipidosis: the liver hyperechoic, compared with falciform fat; the liver isoechoic or hyperechoic, compared with omental fat; poor visualization of intrahepatic vessel borders; and increased attenuation of sound by the liver. In a group of 36 cats with clinically apparent hepatobiliary disease and in which liver biopsy was done, liver hyperechoic, compared with falciform fat, was the best criterion for diagnosis of severe hepatic lipidosis with 91% sensitivity, 100% specificity, and 100% positive predictive value.

  16. Diagnostic accuracy of whole-brain CT perfusion in the detection of acute infratentorial infarctions

    Energy Technology Data Exchange (ETDEWEB)

    Bollwein, Christine; Sommer, Wieland H.; Thierfelder, Kolja M.; Reiser, Maximilian F. [Ludwig-Maximilians-University Hospital of Munich, Institute for Clinical Radiology, Munich (Germany); Plate, Annika; Straube, Andreas; Baumgarten, Louisa von [Ludwig-Maximilians-University Hospital of Munich, Department of Neurology, Munich (Germany); Janssen, Hendrik [South Nuremberg Hospital, Department of Neuroradiology, Nuremberg (Germany)

    2016-11-15

    Although the diagnostic performance of whole-brain computed tomographic perfusion (WB-CTP) in the detection of supratentorial infarctions is well established, its value in the detection of infratentorial strokes remains less well defined. We examined its diagnostic accuracy in the detection of infratentorial infarctions and compared it to nonenhanced computed tomography (NECT), aiming to identify factors influencing its detection rate. Out of a cohort of 1380 patients who underwent WB-CTP due to suspected stroke, we retrospectively included all patients with MRI-confirmed infratentorial strokes and compared it to control patients without infratentorial strokes. Two blinded readers evaluated NECT and four different CTP maps independently for the presence and location of infratentorial ischemic perfusion deficits. The study was designed as a retrospective case-control study and included 280 patients (cases/controls = 1/3). WB-CTP revealed a greater diagnostic sensitivity than NECT (41.4 vs. 17.1 %, P = 0.003). The specificity, however, was comparable (93.3 vs. 95.0 %). Mean transit time (MTT) and time to drain (TTD) were the most sensitive (41.4 and 40.0 %) and cerebral blood volume (CBV) the most specific (99.5 %) perfusion maps. Infarctions detected using WB-CTP were significantly larger than those not detected (15.0 vs. 2.2 ml; P = 0.0007); infarct location, however, did not influence the detection rate. The detection of infratentorial infarctions can be improved by assessing WB-CTP as part of the multimodal stroke workup. However, it remains a diagnostic challenge, especially small volume infarctions in the brainstem are likely to be missed. (orig.)

  17. Diagnostic accuracy of whole-brain CT perfusion in the detection of acute infratentorial infarctions

    International Nuclear Information System (INIS)

    Bollwein, Christine; Sommer, Wieland H.; Thierfelder, Kolja M.; Reiser, Maximilian F.; Plate, Annika; Straube, Andreas; Baumgarten, Louisa von; Janssen, Hendrik

    2016-01-01

    Although the diagnostic performance of whole-brain computed tomographic perfusion (WB-CTP) in the detection of supratentorial infarctions is well established, its value in the detection of infratentorial strokes remains less well defined. We examined its diagnostic accuracy in the detection of infratentorial infarctions and compared it to nonenhanced computed tomography (NECT), aiming to identify factors influencing its detection rate. Out of a cohort of 1380 patients who underwent WB-CTP due to suspected stroke, we retrospectively included all patients with MRI-confirmed infratentorial strokes and compared it to control patients without infratentorial strokes. Two blinded readers evaluated NECT and four different CTP maps independently for the presence and location of infratentorial ischemic perfusion deficits. The study was designed as a retrospective case-control study and included 280 patients (cases/controls = 1/3). WB-CTP revealed a greater diagnostic sensitivity than NECT (41.4 vs. 17.1 %, P = 0.003). The specificity, however, was comparable (93.3 vs. 95.0 %). Mean transit time (MTT) and time to drain (TTD) were the most sensitive (41.4 and 40.0 %) and cerebral blood volume (CBV) the most specific (99.5 %) perfusion maps. Infarctions detected using WB-CTP were significantly larger than those not detected (15.0 vs. 2.2 ml; P = 0.0007); infarct location, however, did not influence the detection rate. The detection of infratentorial infarctions can be improved by assessing WB-CTP as part of the multimodal stroke workup. However, it remains a diagnostic challenge, especially small volume infarctions in the brainstem are likely to be missed. (orig.)

  18. Spatial- and Time-Correlated Detection of Fission Fragments

    Directory of Open Access Journals (Sweden)

    Platkevic M.

    2012-02-01

    Full Text Available With the goal to measure angular correlations of fission fragments in rare fission decay (e.g. ternary and quaternary fission, a multi-detector coincidence system based on two and up to four position sensitive pixel detectors Timepix has been built. In addition to the high granularity, wide dynamic range and per pixel signal threshold, these devices are equipped with per pixel energy and time sensitivity providing more information (position, energy, time, enhances particle-type identification and selectivity of event-by-event detection. Operation of the device with the integrated USB 2.0 based readout interface FITPix and the control and data acquisition software tool Pixelman enables online visualization and flexible/adjustable operation for a different type of experiments. Spatially correlated fission fragments can be thus registered in coincidence. Similarly triggered measurements are performed using an integrated spectrometric module with analogue signal chain electronics. The current status of development together with demonstration of the technique with a 252Cf source is presented.

  19. Detecting, anticipating, and predicting critical transitions in spatially extended systems.

    Science.gov (United States)

    Kwasniok, Frank

    2018-03-01

    A data-driven linear framework for detecting, anticipating, and predicting incipient bifurcations in spatially extended systems based on principal oscillation pattern (POP) analysis is discussed. The dynamics are assumed to be governed by a system of linear stochastic differential equations which is estimated from the data. The principal modes of the system together with corresponding decay or growth rates and oscillation frequencies are extracted as the eigenvectors and eigenvalues of the system matrix. The method can be applied to stationary datasets to identify the least stable modes and assess the proximity to instability; it can also be applied to nonstationary datasets using a sliding window approach to track the changing eigenvalues and eigenvectors of the system. As a further step, a genuinely nonstationary POP analysis is introduced. Here, the system matrix of the linear stochastic model is time-dependent, allowing for extrapolation and prediction of instabilities beyond the learning data window. The methods are demonstrated and explored using the one-dimensional Swift-Hohenberg equation as an example, focusing on the dynamics of stochastic fluctuations around the homogeneous stable state prior to the first bifurcation. The POP-based techniques are able to extract and track the least stable eigenvalues and eigenvectors of the system; the nonstationary POP analysis successfully predicts the timing of the first instability and the unstable mode well beyond the learning data window.

  20. Spatial Cluster Detection for Repeatedly Measured Outcomes while Accounting for Residential History

    OpenAIRE

    Cook, Andrea J.; Gold, Diane R.; Li, Yi

    2009-01-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information ...

  1. Diagnostic accuracy of transesophageal echocardiogram for the detection of patent foramen ovale: a meta-analysis.

    Science.gov (United States)

    Mojadidi, Mohammad Khalid; Bogush, Nikolay; Caceres, Jose Diego; Msaouel, Pavlos; Tobis, Jonathan M

    2014-07-01

    Patent foramen ovale (PFO) is a remnant of the fetal circulation present in 20% of the population. Right-to-left shunting (RLS) through a PFO has been linked to the pathophysiology of stroke, migraine with aura, and hypoxemia. While different imaging modalities including transcranial Doppler, intra-cardiac echo, and transthoracic echo (TTE) have often been used to detect RLS, transesophageal echo (TEE) bubble study remains the gold standard for diagnosing PFO. The aim of this study was to determine the relative accuracy of TEE in the detection of PFO. A systematic review of Medline, using a standard approach for meta-analysis, was performed for all prospective studies assessing accuracy of TEE in the detection of PFO using confirmation by autopsy, cardiac surgery, and/or catheterization as the reference. Search results revealed 3105 studies; 4 met inclusion criteria. A total of 164 patients were included. TEE had a weighted sensitivity of 89.2% (95% CI: 81.1-94.7%) and specificity of 91.4% (95% CI: 82.3-96.8%) to detect PFO. The overall positive likelihood ratio (LR+) was 5.93 (95% CI: 1.30-27.09) and the overall negative likelihood ratio (LR-) was 0.22 (95% CI: 0.08-0.56). While TEE bubble study is considered to be the gold standard modality for diagnosing PFO, some PFOs may still be missed or misdiagnosed. It is important to understand the limitations of TEE and perhaps use other highly sensitive screening tests, such as transcranial doppler (TCD), in conjunction with TEE before scheduling a patient for transcatheter PFO closure. © 2013, Wiley Periodicals, Inc.

  2. Diagnostic Accuracy of Ascites Fluid Gross Appearance in Detection of Spontaneous Bacterial Peritonitis.

    Science.gov (United States)

    Aminiahidashti, Hamed; Hosseininejad, Seyed Mohammad; Montazer, Hosein; Bozorgi, Farzad; Goli Khatir, Iraj; Jahanian, Fateme; Raee, Behnaz

    2014-01-01

    Spontaneous bacterial peritonitis (SBP) as a monomicrobial infection of ascites fluid is one of the most important causes of morbidity and mortality in cirrhotic patients. This study was aimed to determine the diagnostic accuracy of ascites fluid color in detection of SBP in cirrhotic cases referred to the emergency department. Cirrhotic patients referred to the ED for the paracentesis of ascites fluid were enrolled. For all studied patients, the results of laboratory analysis and gross appearance of ascites fluid registered and reviewed by two emergency medicine specialists. The sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ration of the ascites fluid gross appearance in detection of SBP were measured with 95% confidence interval. The present project was performed in 80 cirrhotic patients with ascites (52.5 female). The mean of the subjects' age was 56.25±12.21 years (35-81). Laboratory findings revealed SBP in 23 (29%) cases. Fifty nine (73%) cases had transparent ascites fluid appearance of whom 17 (29%) ones suffered from SBP. From 21 (26%) cases with opaque ascites appearance, 15 (71%) had SBP. The sensitivity and specificity of the ascites fluid appearance in detection of SBP were 46.88% (Cl: 30.87-63.55) and 87.50% (95% Cl: 75.3-94.14), respectively. It seems that the gross appearance of ascites fluid had poor diagnostic accuracy in detection of SBP and considering its low sensitivity, it could not be used as a good screening tool for this propose.

  3. Diagnostic Accuracy of Ascites Fluid Gross Appearance in Detection of Spontaneous Bacterial Peritonitis

    Directory of Open Access Journals (Sweden)

    Hamed Aminiahidashti

    2014-08-01

    Full Text Available Introduction: Spontaneous bacterial peritonitis (SBP as a monomicrobial infection of ascites fluid is one of the most important causes of morbidity and mortality in cirrhotic patients. This study was aimed to determine the diagnostic accuracy of ascites fluid color in detection of SBP in cirrhotic cases referred to the emergency department. Methods: Cirrhotic patients referred to the ED for the paracentesis of ascites fluid were enrolled. For all studied patients, the results of laboratory analysis and gross appearance of ascites fluid registered and reviewed by two emergency medicine specialists. The sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ration of the ascites fluid gross appearance in detection of SBP were measured with 95% confidence interval. Results: The present project was performed in 80 cirrhotic patients with ascites (52.5 female. The mean of the subjects’ age was 56.25±12.21 years (35-81. Laboratory findings revealed SBP in 23 (29% cases. Fifty nine (73% cases had transparent ascites fluid appearance of whom 17 (29% ones suffered from SBP. From 21 (26% cases with opaque ascites appearance, 15 (71% had SBP. The sensitivity and specificity of the ascites fluid appearance in detection of SBP were 46.88% (Cl: 30.87-63.55 and 87.50% (95% Cl: 75.3-94.14, respectively. Conclusion: It seems that the gross appearance of ascites fluid had poor diagnostic accuracy in detection of SBP and considering its low sensitivity, it could not be used as a good screening tool for this propose.

  4. Accuracy of High-Resolution Ultrasonography in the Detection of Extensor Tendon Lacerations.

    Science.gov (United States)

    Dezfuli, Bobby; Taljanovic, Mihra S; Melville, David M; Krupinski, Elizabeth A; Sheppard, Joseph E

    2016-02-01

    Lacerations to the extensor mechanism are usually diagnosed clinically. Ultrasound (US) has been a growing diagnostic tool for tendon injuries since the 1990s. To date, there has been no publication establishing the accuracy and reliability of US in the evaluation of extensor mechanism lacerations in the hand. The purpose of this study is to determine the accuracy of US to detect extensor tendon injuries in the hand. Sixteen fingers and 4 thumbs in 4 fresh-frozen and thawed cadaveric hands were used. Sixty-eight 0.5-cm transverse skin lacerations were created. Twenty-seven extensor tendons were sharply transected. The remaining skin lacerations were used as sham dissection controls. One US technologist and one fellowship-trained musculoskeletal radiologist performed real-time dynamic US studies in and out of water bath. A second fellowship trained musculoskeletal radiologist subsequently reviewed the static US images. Dynamic and static US interpretation accuracy was assessed using dissection as "truth." All 27 extensor tendon lacerations and controls were identified correctly with dynamic imaging as either injury models that had a transected extensor tendon or sham controls with intact extensor tendons (sensitivity = 100%, specificity = 100%, positive predictive value = 1.0; all significantly greater than chance). Static imaging had a sensitivity of 85%, specificity of 89%, and accuracy of 88% (all significantly greater than chance). The results of the dynamic real time versus static US imaging were clearly different but did not reach statistical significance. Diagnostic US is a very accurate noninvasive study that can identify extensor mechanism injuries. Clinically suspected cases of acute extensor tendon injury scanned by high-frequency US can aid and/or confirm the diagnosis, with dynamic imaging providing added value compared to static. Ultrasonography, to aid in the diagnosis of extensor mechanism lacerations, can be successfully used in a reliable and

  5. A systematic review on diagnostic accuracy of CT-based detection of significant coronary artery disease

    International Nuclear Information System (INIS)

    Janne d'Othee, Bertrand; Siebert, Uwe; Cury, Ricardo; Jadvar, Hossein; Dunn, Edward J.; Hoffmann, Udo

    2008-01-01

    Objectives: Systematic review of diagnostic accuracy of contrast enhanced coronary computed tomography (CE-CCT). Background: Noninvasive detection of coronary artery stenosis (CAS) by CE-CCT as an alternative to catheter-based coronary angiography (CCA) may improve patient management. Methods: Forty-one articles published between 1997 and 2006 were included that evaluated native coronary arteries for significant stenosis and used CE-CCT as diagnostic test and CCA as reference standard. Study group characteristics, study methodology and diagnostic outcomes were extracted. Pooled summary sensitivity and specificity of CE-CCT were calculated using a random effects model (1) for all coronary segments, (2) assessable segments, and (3) per patient. Results: The 41 studies totaled 2515 patients (75% males; mean age: 59 years, CAS prevalence: 59%). Analysis of all coronary segments yielded a sensitivity of 95% (80%, 89%, 86%, 98% for electron beam CT, 4/8-slice, 16-slice and 64-slice MDCT, respectively) for a specificity of 85% (77%, 84%, 95%, 91%). Analysis limited to segments deemed assessable by CT showed sensitivity of 96% (86%, 85%, 98%, 97%) for a specificity of 95% (90%, 96%, 96%, 96%). Per patient, sensitivity was 99% (90%, 97%, 99%, 98%) and specificity was 76% (59%, 81%, 83%, 92%). Heterogeneity was quantitatively important but not explainable by patient group characteristics or study methodology. Conclusions: Current diagnostic accuracy of CE-CCT is high. Advances in CT technology have resulted in increases in diagnostic accuracy and proportion of assessable coronary segments. However, per patient, accuracy may be lower and CT may have more limited clinical utility in populations at high risk for CAD

  6. Early detection of tuberculosis outbreaks among the San Francisco homeless: trade-offs between spatial resolution and temporal scale.

    Directory of Open Access Journals (Sweden)

    Brandon W Higgs

    Full Text Available BACKGROUND: San Francisco has the highest rate of tuberculosis (TB in the U.S. with recurrent outbreaks among the homeless and marginally housed. It has been shown for syndromic data that when exact geographic coordinates of individual patients are used as the spatial base for outbreak detection, higher detection rates and accuracy are achieved compared to when data are aggregated into administrative regions such as zip codes and census tracts. We examine the effect of varying the spatial resolution in the TB data within the San Francisco homeless population on detection sensitivity, timeliness, and the amount of historical data needed to achieve better performance measures. METHODS AND FINDINGS: We apply a variation of space-time permutation scan statistic to the TB data in which a patient's location is either represented by its exact coordinates or by the centroid of its census tract. We show that the detection sensitivity and timeliness of the method generally improve when exact locations are used to identify real TB outbreaks. When outbreaks are simulated, while the detection timeliness is consistently improved when exact coordinates are used, the detection sensitivity varies depending on the size of the spatial scanning window and the number of tracts in which cases are simulated. Finally, we show that when exact locations are used, smaller amount of historical data is required for training the model. CONCLUSION: Systematic characterization of the spatio-temporal distribution of TB cases can widely benefit real time surveillance and guide public health investigations of TB outbreaks as to what level of spatial resolution results in improved detection sensitivity and timeliness. Trading higher spatial resolution for better performance is ultimately a tradeoff between maintaining patient confidentiality and improving public health when sharing data. Understanding such tradeoffs is critical to managing the complex interplay between public

  7. Accuracy rate of pregnancy detection in dairy cow by measuring the early pregnancy factor

    Directory of Open Access Journals (Sweden)

    S Mosaferi

    2007-08-01

    Full Text Available Early pregnancy factor (EPF a protein with immunosuppressive properties can be detected in the serum of most domestic animals at early pregnancy. In this study, pregnancy detection in 41 dairy cows following artificial insemination was evaluated by detecting EPF in blood serum using the rosette inhibition test (RIT. The amount of EPF activity 1-3 and 4-7 days after artificial insemination of cows was measured by RIT. Pregnancies were confirmed 45-60 days after insemination by rectal palpation. The results indicated that sensitivity, specificity, positive predictive value, negative predictive value and accuracy of this technique in detecting pregnancy 1-3 days following insemination was 88.88,  66.66,  72.72,  85.71  and  77.77 percent  respectively and RIT titers of above 8 and below 4 were seen in pregnant and non-pregnant animals at this period. The value of the above parameters were 91,  83.83,  83.33,  91  and  87 percent  respectively  4-7  days  after insemination and also RIT titers of above 8 and below 4 were achieved in pregnant and non pregnant cows during this period. The results of this study indicated that there are significant differences in RIT titers between pregnant and non-pregnant cows 1-3 and 4-7 days following artificial insemination (P

  8. A new device for liver cancer biomarker detection with high accuracy

    Directory of Open Access Journals (Sweden)

    Shuaipeng Wang

    2015-06-01

    Full Text Available A novel cantilever array-based bio-sensor was batch-fabricated with IC compatible MEMS technology for precise liver cancer bio-marker detection. A micro-cavity was designed in the free end of the cantilever for local antibody-immobilization, thus adsorption of the cancer biomarker is localized in the micro-cavity, and the adsorption-induced k variation can be dramatically reduced with comparison to that caused by adsorption of the whole lever. The cantilever is pizeoelectrically driven into vibration which is pizeoresistively sensed by Wheatstone bridge. These structural features offer several advantages: high sensitivity, high throughput, high mass detection accuracy, and small volume. In addition, an analytical model has been established to eliminate the effect of adsorption-induced lever stiffness change and has been applied to precise mass detection of cancer biomarker AFP, the detected AFP antigen mass (7.6 pg/ml is quite close to the calculated one (5.5 pg/ml, two orders of magnitude better than the value by the fully antibody-immobilized cantilever sensor. These approaches will promote real application of the cantilever sensors in early diagnosis of cancer.

  9. Accuracy of digital peripical radiography and cone-beam computed tomography in detecting external root resorption

    Energy Technology Data Exchange (ETDEWEB)

    Creanga, Adriana Gabriela [Division of Dental Diagnostic Science, Rutgers School of Dental Medicine, Newark (United States); Geha, Hassem; Sankar, Vidya; Mcmahan, Clyde Alex; Noujeim, Marcel [University of Texas Health Science Center San Antonio, San Antonio (United States); Teixeira, Fabrico B. [Dept. of Endodontics, University of Iowa, Iowa City (United States)

    2015-09-15

    The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

  10. A comparison between conventional radiography and digitized image accuracy in proximal caries detection

    Directory of Open Access Journals (Sweden)

    Pangnoosh M

    2003-08-01

    Full Text Available Statement of Problem: Computer Sciences, in radiology, like other fields, is of high importance. It should"nalso be noted that the accuracy of the technique and work conditions affects the radiographs information"nconsiderably. There for, in order to get more accurate diagnostic information, it seems necessary to investigate"ndifferent digitized radiographic techniques and to compare them with the conventional technique."nPurpose: The aim of this study was to compare the accuracy of conventional and digitized radiographic"nimages by three digitization techniques in proximal caries detection."nMaterial and Methods: In this research study, sixty extracted human canines, premolars and molars were"nmounted in blocks and imaged on E-Kodak film, similar to bitewing radiographs. Ten bitewing radiographs"nwere then scanned at 600 d.p.i with flat bed scanner and a digital camera, then digitized at 300 d.p.i with"nanother digital camera. The digitized images were displayed randomly on a high-resolution monitor. Six"nobservers assessed the caries status of 120 proximal surfaces by conventional and digitized images. The"nobserver's scores were compared with the results of the macroscopic examination. Reliability of each"ntechnique was calculated. Data were analyzed using chi-square and ANOVA tests."nResults: No significant differences were detected between different techniques in intact proximal surfaces and"nenamel caries diagnosis. However, digital techniques were more sensitive in dentin caries detection (P<0.05."nConclusions: When conventional film images are digitized, medium resolution (300 d.p.i seems to be"nsufficient. At this resolution the file size is decreased and there is no significant loss of the information"nnecessary for caries diagnosis.

  11. The diagnostic accuracy of endovaginal and transperineal ultrasound for detecting anal sphincter defects: The PREDICT study

    Energy Technology Data Exchange (ETDEWEB)

    Roos, A.-M., E-mail: annemarie.roos@gmail.com [Department of Obstetrics and Gynaecology, Mayday University Hospital, Croydon (United Kingdom); Abdool, Z. [Department of Obstetrics and Gynaecology, University of Pretoria, Pretoria (South Africa); Sultan, A.H.; Thakar, R. [Department of Obstetrics and Gynaecology, Mayday University Hospital, Croydon (United Kingdom)

    2011-07-15

    Aim: To determine the accuracy and predictive value of transperineal (TPU) and endovaginal ultrasound (EVU) in the detection of anal sphincter defects in women with obstetric anal sphincter injuries and/or postpartum symptoms of faecal incontinence. Materials and methods: One hundred and sixty-five women were recruited, four women were excluded as they were seen years after their last delivery. TPU and EVU, followed by endonanal ultrasound (EAU), were performed using the B and K Viking 2400 scanner. Sensitivity and specificity, as well as predictive values with 95% confidence intervals, for detecting anal sphincter defects were calculated for EVU and TPU, using EAU as the reference standard. Results: On EAU a defect was found in 42 (26%) women: 39 (93%) had an external (EAS) and 23 (55%) an internal anal sphincter (IAS) defect. Analysable images of one level of the EAS combined with an analysable IAS were available in 140 (87%) women for EVU and in 131 (81%) for TPU. The sensitivity and specificity for the detection of any defect was 48% (30-67%) and 85% (77-91%) for EVU and 64% (44-81%) and 85% (77-91%) for TPU, respectively. Conclusion: Although EAU using a rotating endoprobe is the validated reference standard in the identification of anal sphincter defects, it is not universally available. However while TPU and/or EVU with conventional ultrasound probes can be useful in identifying normality, for clinical purposes they are not sensitive enough to identify an underlying sphincter defect.

  12. The diagnostic accuracy of endovaginal and transperineal ultrasound for detecting anal sphincter defects: The PREDICT study

    International Nuclear Information System (INIS)

    Roos, A.-M.; Abdool, Z.; Sultan, A.H.; Thakar, R.

    2011-01-01

    Aim: To determine the accuracy and predictive value of transperineal (TPU) and endovaginal ultrasound (EVU) in the detection of anal sphincter defects in women with obstetric anal sphincter injuries and/or postpartum symptoms of faecal incontinence. Materials and methods: One hundred and sixty-five women were recruited, four women were excluded as they were seen years after their last delivery. TPU and EVU, followed by endonanal ultrasound (EAU), were performed using the B and K Viking 2400 scanner. Sensitivity and specificity, as well as predictive values with 95% confidence intervals, for detecting anal sphincter defects were calculated for EVU and TPU, using EAU as the reference standard. Results: On EAU a defect was found in 42 (26%) women: 39 (93%) had an external (EAS) and 23 (55%) an internal anal sphincter (IAS) defect. Analysable images of one level of the EAS combined with an analysable IAS were available in 140 (87%) women for EVU and in 131 (81%) for TPU. The sensitivity and specificity for the detection of any defect was 48% (30-67%) and 85% (77-91%) for EVU and 64% (44-81%) and 85% (77-91%) for TPU, respectively. Conclusion: Although EAU using a rotating endoprobe is the validated reference standard in the identification of anal sphincter defects, it is not universally available. However while TPU and/or EVU with conventional ultrasound probes can be useful in identifying normality, for clinical purposes they are not sensitive enough to identify an underlying sphincter defect.

  13. Clinical relevance of studies on the accuracy of visual inspection for detecting caries lesions

    DEFF Research Database (Denmark)

    Gimenez, Thais; Piovesan, Chaiana; Braga, Mariana M

    2015-01-01

    Although visual inspection is the most commonly used method for caries detection, and consequently the most investigated, studies have not been concerned about the clinical relevance of this procedure. Therefore, we conducted a systematic review in order to perform a critical evaluation considering...... the clinical relevance and methodological quality of studies on the accuracy of visual inspection for assessing caries lesions. Two independent reviewers searched several databases through July 2013 to identify papers/articles published in English. Other sources were checked to identify unpublished literature...... to clinical relevance and the methodological quality of the studies were evaluated. 96 of the 5,578 articles initially identified met the inclusion criteria. In general, most studies failed in considering some clinically relevant aspects: only 1 included study validated activity status of lesions, no study...

  14. Applying signal-detection theory to the study of observer accuracy and bias in behavioral assessment.

    Science.gov (United States)

    Lerman, Dorothea C; Tetreault, Allison; Hovanetz, Alyson; Bellaci, Emily; Miller, Jonathan; Karp, Hilary; Mahmood, Angela; Strobel, Maggie; Mullen, Shelley; Keyl, Alice; Toupard, Alexis

    2010-01-01

    We evaluated the feasibility and utility of a laboratory model for examining observer accuracy within the framework of signal-detection theory (SDT). Sixty-one individuals collected data on aggression while viewing videotaped segments of simulated teacher-child interactions. The purpose of Experiment 1 was to determine if brief feedback and contingencies for scoring accurately would bias responding reliably. Experiment 2 focused on one variable (specificity of the operational definition) that we hypothesized might decrease the likelihood of bias. The effects of social consequences and information about expected behavior change were examined in Experiment 3. Results indicated that feedback and contingencies reliably biased responding and that the clarity of the definition only moderately affected this outcome.

  15. Diagnostic Accuracy of Nonmydriatic Fundus Photography for the Detection of Glaucoma in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Francisco J. Muñoz-Negrete

    2015-01-01

    Full Text Available Purpose. To determine the diagnostic accuracy for glaucoma of a set of criteria with nonmydriatic monoscopic fundus photography (NMFP in diabetics. Methods. Diabetics recruited from a screening program for diabetic retinopathy and diabetic glaucoma patients recruited from our glaucoma unit were included. Any patient with evidence of diabetic retinopathy was excluded. Diabetic patients had to have no visual field defects to be included as controls. Glaucoma patients had to have a glaucomatous field defect in at least one eye to be included. One NMFP was taken per eye for all subjects. These photographs were evaluated by two masked glaucoma specialists for the presence of the following: bilateral cup to disc (C/D ratio ≥0.6, notching or thinning of the neuroretinal rim, disc hemorrhages, and asymmetry in the C/D ratio between both eyes ≥0.2. This evaluation led to a dichotomous classification: if any of the above criteria was present, the patient was classified as glaucoma. If none were present, the patient was classified as normal. Results. 72 control subjects and 72 glaucoma patients were included. Evaluation of NMFP had a sensitivity of 79.17% and a specificity of 80.56% for specialist 1 and a sensitivity of 72.22% and a specificity of 88.88% for specialist 2 for the detection of glaucoma. The overall accuracy was 79.83% and 80.55%, respectively. Discussion. NMFP evaluation by a glaucoma specialist may be useful for the detection of glaucoma in diabetics.

  16. Diagnostic accuracy of serum activin A in detection of ectopic pregnancy

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Roghaei

    2012-01-01

    Full Text Available Background: Ectopic pregnancy (EP still remains a main cause of maternal mortalities. This study is designed to evaluate the accuracy of serum Activin A in detection of ectopic pregnancy. Methods : This prospective observational study was conducted from 2009 to 2010 at two main referral university hospitals, Isfahan University of Medical Sciences, Isfahan, Iran. Two hundred subjects who were under 10 week′s pregnancy with clinical presentations of abdominal pain and vaginal bleeding were enrolled. After sampling serum Activin A, patients underwent ultrasonography, titer of B-HCG and surgery (if indicated and were divided into two groups: EP (n = 100 and intrauterine pregnancy (IUP (n = 100. The mean of Activin A was compared between groups and by ROC curve, the optimal cut off with sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV were determined. Results : The mean age of women with IUP was 25.4 ± 4.3 years (15-40 years compared with 25.9 ± 4.1 years in women in EP group (P = 0.448. Statistical difference was not found between EP versus IUP groups in gestational age (6.32 ± 1.03 vs. 6.85 ± 1.82 weeks, P = 0.124. The mean of serum Activin A in EP group was 0.264 ± 0.0703 ng/ml versus 0.949 ± 0.5283 ng/ml in IUP group (P < 0.05. According to ROC curve (area under the curve = 0.981, P < 0.05, confidence interval: 0.961-1.000, the optimal cut off was estimated as 0.504 ng/ml with sensitivity of 97% and specificity of 93.5%. Conclusion : This study indicated that the mean of serum Activin A is lower in EP compared with IUP. The serum Activin A has a fair accuracy in detecting EP.

  17. Step detection and activity recognition accuracy of seven physical activity monitors.

    Directory of Open Access Journals (Sweden)

    Fabio A Storm

    Full Text Available The aim of this study was to compare the seven following commercially available activity monitors in terms of step count detection accuracy: Movemonitor (Mc Roberts, Up (Jawbone, One (Fitbit, ActivPAL (PAL Technologies Ltd., Nike+ Fuelband (Nike Inc., Tractivity (Kineteks Corp. and Sensewear Armband Mini (Bodymedia. Sixteen healthy adults consented to take part in the study. The experimental protocol included walking along an indoor straight walkway, descending and ascending 24 steps, free outdoor walking and free indoor walking. These tasks were repeated at three self-selected walking speeds. Angular velocity signals collected at both shanks using two wireless inertial measurement units (OPAL, ADPM Inc were used as a reference for the step count, computed using previously validated algorithms. Step detection accuracy was assessed using the mean absolute percentage error computed for each sensor. The Movemonitor and the ActivPAL were also tested within a nine-minute activity recognition protocol, during which the participants performed a set of complex tasks. Posture classifications were obtained from the two monitors and expressed as a percentage of the total task duration. The Movemonitor, One, ActivPAL, Nike+ Fuelband and Sensewear Armband Mini underestimated the number of steps in all the observed walking speeds, whereas the Tractivity significantly overestimated step count. The Movemonitor was the best performing sensor, with an error lower than 2% at all speeds and the smallest error obtained in the outdoor walking. The activity recognition protocol showed that the Movemonitor performed best in the walking recognition, but had difficulty in discriminating between standing and sitting. Results of this study can be used to inform choice of a monitor for specific applications.

  18. Step detection and activity recognition accuracy of seven physical activity monitors.

    Science.gov (United States)

    Storm, Fabio A; Heller, Ben W; Mazzà, Claudia

    2015-01-01

    The aim of this study was to compare the seven following commercially available activity monitors in terms of step count detection accuracy: Movemonitor (Mc Roberts), Up (Jawbone), One (Fitbit), ActivPAL (PAL Technologies Ltd.), Nike+ Fuelband (Nike Inc.), Tractivity (Kineteks Corp.) and Sensewear Armband Mini (Bodymedia). Sixteen healthy adults consented to take part in the study. The experimental protocol included walking along an indoor straight walkway, descending and ascending 24 steps, free outdoor walking and free indoor walking. These tasks were repeated at three self-selected walking speeds. Angular velocity signals collected at both shanks using two wireless inertial measurement units (OPAL, ADPM Inc) were used as a reference for the step count, computed using previously validated algorithms. Step detection accuracy was assessed using the mean absolute percentage error computed for each sensor. The Movemonitor and the ActivPAL were also tested within a nine-minute activity recognition protocol, during which the participants performed a set of complex tasks. Posture classifications were obtained from the two monitors and expressed as a percentage of the total task duration. The Movemonitor, One, ActivPAL, Nike+ Fuelband and Sensewear Armband Mini underestimated the number of steps in all the observed walking speeds, whereas the Tractivity significantly overestimated step count. The Movemonitor was the best performing sensor, with an error lower than 2% at all speeds and the smallest error obtained in the outdoor walking. The activity recognition protocol showed that the Movemonitor performed best in the walking recognition, but had difficulty in discriminating between standing and sitting. Results of this study can be used to inform choice of a monitor for specific applications.

  19. Multidetector CT of the coronary imaging: assessment of image quality and accuracy in detecting stenoses

    International Nuclear Information System (INIS)

    Huang Meiping; Liu Qishun; Liu Hui; Liang Changhong; Zhang Shaobin

    2006-01-01

    Objective: To evaluate the image quality of 64-multi detector computed tomography (MDCT) and the clinical accuracy in detecting coronary artery lesions. Methods: One hundred and five patients were studied by MDCT. The results were compared with invasive coronary angiography (ICA). Patients were excluded for atrial fibrillation, but not for high heart rate, coronary calcification, or obesity. MDCT was analyzed with regard to image quality and presence of coronary artery lesions. Results: The data evaluation of the image quality was based on a total of 1365 segments (13 coronary segments for each patient), of which 1144 segments were considered to have diagnostic image quality, but 221 segments (16.2%) could not be sufficiently evaluated because of severe calcifications (153 segments) and motion artifacts (68 segments). The median calcium score [Agatston score equivalent (ASE)] was 154 (range 0--1983). 87 of the 105 patients had an ASE of less than 1,000 [median 105 (range 0-994)], and 18 patients had an ASE greater than 1000 [median 1477 (range 1115-1983)]. For detecting lesions with 50% or greater narrowing (without any exclusion criteria), the overall sensitivity, specificity, positive predictive value, and negative predictive value were 85.7%, 97.9%, 93.0%, and 95.5%, respectively. When limiting the number of patients to those with a calcium score of less than 1000 ASE, the threshold- corrected sensitivity for lesions with 50% or greater narrowing was 96.0%; specificity, 98.9%; positive predictive value, 95.3%; and negative predictive value, 99.0%. Conclusion: Our results indicate high quantitative and qualitative diagnostic accuracy of 64-slice MSCT in comparison to QCA in a broad spectrum of patients. (authors)

  20. Diagnostic Accuracy of Clinical Methods for Detection of Diabetic Sensory Neuropathy

    International Nuclear Information System (INIS)

    Arshad, A. R.; Alvi, K. Y.

    2016-01-01

    Objective: To determine the accuracy of clinical methods for detection of sensory neuropathy as compared to biothesiometry. Study Design: Cross-sectional analytical study. Place and Duration of Study: 1 Mountain Medical Battalion, Azad Kashmir, from October 2013 to September 2014. Methodology: Patients with type 2 diabetes were enrolled by convenience sampling. Exclusion criteria included other identifiable causes of neuropathy, extensive ulceration of feet, amputated feet, those on treatment for neuropathy and unwilling patients. Average of 3 vibration perception threshold values measured with a biothesiometer on distal hallux was calculated. Ten gm monofilament was used to examine touch sensation over dorsal surfaces of great toes. Vibration sensation was checked over the tips of great toes using 128Hz tuning fork. Ankle jerks were checked bilaterally. Result: Neuropathy (vibration perception threshold > 25 volts) was present in 34 (21.12 percentage) out of 161 patients and 93 (57.76 percentage) were symptomatic. Measures of diagnostic accuracy for monofilament, tuning fork and ankle jerks were: sensitivity 41.18 percentage, 55.88 percentage and 64.71 percentage; specificity 92.91 percentage, 93.70 percentage and 80.31 percentage; positive predictive value (PPV) 60.87 percentage, 70.37 percentage and 46.81 percentage; negative predictive value (NPV) 85.51 percentage, 88.81 percentage and 89.47 percentage; and, diagnostic accuracy 81.99 percentage, 85.71 percentage and 77.02 percentage, respectively. Values for any 1 positive sign, any 2 positive signs or all 3 positive signs were: sensitivity 35.29 percentage, 14.71 percentage and 32.35 percentage; specificity 81.89 percentage, 93.70 percentage and 99.21 percentage; PPV 34.29 percentage, 38.46 percentage and 91.67 percentage; NPV 82.54 percentage, 80.41 percentage and 84.56 percentage; and, diagnostic accuracy 72.05 percentage, 77.02 percentage and 85.09 percentage, respectively. Conclusion: Clinical methods are

  1. Review: Diagnostic accuracy of PCR-based detection tests for Helicobacter Pylori in stool samples.

    Science.gov (United States)

    Khadangi, Fatemeh; Yassi, Maryam; Kerachian, Mohammad Amin

    2017-12-01

    Although different methods have been established to detect Helicobacter pylori (H. pylori) infection, identifying infected patients is an ongoing challenge. The aim of this meta-analysis was to provide pooled diagnostic accuracy measures for stool PCR test in the diagnosis of H. pylori infection. In this study, a systematic review and meta-analysis were carried out on various sources, including MEDLINE, Web of Sciences, and the Cochrane Library from April 1, 1999, to May 1, 2016. This meta-analysis adheres to the guidelines provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses report (PRISMA Statement). The clinical value of DNA stool PCR test was based on the pooled false positive, false negative, true positive, and true negative of different genes. Twenty-six of 328 studies identified met the eligibility criteria. Stool PCR test had a performance of 71% (95% CI: 68-73) sensitivity, 96% (95% CI: 94-97) specificity, and 65.6 (95% CI: 30.2-142.5) diagnostic odds ratio (DOR) in diagnosis of H. pylori. The DOR of genes which showed the highest performance of stool PCR tests was as follows: 23S rRNA 152.5 (95% CI: 55.5-418.9), 16S rRNA 67.9 (95%CI: 6.4-714.3), and glmM 68.1 (95%CI: 20.1-231.7). The sensitivity and specificity of stool PCR test are relatively in the same spectrum of other diagnostic methods for the detection of H. pylori infection. In descending order of significance, the most diagnostic candidate genes using PCR detection were 23S rRNA, 16S rRNA, and glmM. PCR for 23S rRNA gene which has the highest performance could be applicable to detect H. pylori infection. © 2017 John Wiley & Sons Ltd.

  2. Accuracy of the Spot and Plusoptix photoscreeners for detection of astigmatism.

    Science.gov (United States)

    Crescioni, Mabel; Miller, Joseph M; Harvey, Erin M

    2015-10-01

    To evaluate the accuracy of the Spot (V2.0.16) and Plusoptix S12 (ROC4, V6.1.4.0) photoscreeners in detecting astigmatism meeting AAPOS referral criteria in students from a population with high prevalence of astigmatism. Students attending grades 3-8 on the Tohono O'odham reservation were examined. Screening was attempted with both the Spot and Plusoptix photoscreeners. Results were compared to cycloplegic refraction. Screening attempts providing no estimate of refractive error were considered fail/refer. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for detection of refractive errors were determined using AAPOS referral criteria and receiver operating characteristic area under the curve (ROC AUC) analysis was conducted for measures of astigmatism. Agreement between screening and cycloplegic refraction measurements of astigmatism, spherical equivalent, and anisometropia were assessed using t tests and correlation analyses. A total of 209 students were included. Of the total, 116 (55%) met examination-positive criteria based on cycloplegic refraction, with 105 of those (90%) meeting the criterion for astigmatism. Measurements success rates were 97% for Spot and 54% for Plusoptix. Comparing the Spot and the Plusoptix, sensitivity was 96% versus 100%, specificity was 87% versus 61%, PPV was 90% versus 76%, and NPV was 94% versus 100% for detection of refractive error. Both screeners overestimated astigmatism by 1/3 D to 2/3 D. AUC for astigmatism was 0.97 for Spot and 0.83 for Plusoptix. In this highly astigmatic population, the Spot and the Plusoptix had similar sensitivity, but the Spot had better specificity and measurement success rates. Compared with results from study samples with lower rates of astigmatism, our results highlight the need to assess the ability of screening instruments to detect individual types of refractive errors. Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus

  3. Accuracy assessment of tree crown detection using local maxima and multi-resolution segmentation

    International Nuclear Information System (INIS)

    Khalid, N; Hamid, J R A; Latif, Z A

    2014-01-01

    Diversity of trees forms an important component in the forest ecosystems and needs proper inventories to assist the forest personnel in their daily activities. However, tree parameter measurements are often constrained by physical inaccessibility to site locations, high costs, and time. With the advancement in remote sensing technology, such as the provision of higher spatial and spectral resolution of imagery, a number of developed algorithms fulfil the needs of accurate tree inventories information in a cost effective and timely manner over larger forest areas. This study intends to generate tree distribution map in Ampang Forest Reserve using the Local Maxima and Multi-Resolution image segmentation algorithm. The utilization of recent worldview-2 imagery with Local Maxima and Multi-Resolution image segmentation proves to be capable of detecting and delineating the tree crown in its accurate standing position

  4. Increasing the Accuracy of Mapping Urban Forest Carbon Density by Combining Spatial Modeling and Spectral Unmixing Analysis

    Directory of Open Access Journals (Sweden)

    Hua Sun

    2015-11-01

    Full Text Available Accurately mapping urban vegetation carbon density is challenging because of complex landscapes and mixed pixels. In this study, a novel methodology was proposed that combines a linear spectral unmixing analysis (LSUA with a linear stepwise regression (LSR, a logistic model-based stepwise regression (LMSR and k-Nearest Neighbors (kNN, to map the forest carbon density of Shenzhen City of China, using Landsat 8 imagery and sample plot data collected in 2014. The independent variables that contributed to statistically significantly improving the fit of a model to data and reducing the sum of squared errors were first selected from a total of 284 spectral variables derived from the image bands. The vegetation fraction from LSUA was then added as an independent variable. The results obtained using cross-validation showed that: (1 Compared to the methods without the vegetation information, adding the vegetation fraction increased the accuracy of mapping carbon density by 1%–9.3%; (2 As the observed values increased, the LSR and kNN residuals showed overestimates and underestimates for the smaller and larger observations, respectively, while LMSR improved the systematical over and underestimations; (3 LSR resulted in illogically negative and unreasonably large estimates, while KNN produced the greatest values of root mean square error (RMSE. The results indicate that combining the spatial modeling method LMSR and the spectral unmixing analysis LUSA, coupled with Landsat imagery, is most promising for increasing the accuracy of urban forest carbon density maps. In addition, this method has considerable potential for accurate, rapid and nondestructive prediction of urban and peri-urban forest carbon stocks with an acceptable level of error and low cost.

  5. Diagnostic accuracy of subcutaneous abdominal fat tissue aspiration for detecting systemic amyloidosis and its utility in clinical practice

    NARCIS (Netherlands)

    van Gameren, Ingrid I.; Hazenberg, BPC; Bijzet, J.; van Rijswijk, M.H.

    Objective. Aspiration of subcutaneous abdominal fat is a simple and fast method for detecting systemic amyloidosis; however, the sensitivity of this approach remains undetermined. The aim of this study was to assess the accuracy of fat tissue aspiration for detecting systemic amyloidosis and the

  6. Contribution to the study of position sensitive detectors with high spatial resolution for thermal neutron detection

    International Nuclear Information System (INIS)

    Idrissi Fakhr-Eddine, Abdellah.

    1978-01-01

    With a view to improving the spatial resolution of the localization of thermal neutrons, the work covers four position sensitive detectors: - 800 cell multi-detectors (1 dimension), - linear 'Jeu de Jacquet' detectors (1 dimension) - Multi-detector XYP 128x128 (2 dimensions), - 'Jeu de Jacquet' detector with 2 dimensions. Mention is made of the various position finding methods known so far, as well as the reasons for selecting BF 3 as detector gas. A study is then made of the parameters of the multiwire chamber whose principle will form the basis of most of the position detecting appliances subsequently dealt with. Finally, a description is given of the detection tests of the thermal neutrons in the multiwire chamber depending on the pressure, a parameter that greatly affects the accuracy of the position finding. The single dimension position tests on two kinds of appliance, the 800 cell multi-detector for the wide angle diffraction studies, and the linear 'Jeu de Jacquet' detector designed for small angle diffraction are mentioned. A description is then given of two position appliances with two dimensions; the multi-detector XYP 128x128 and the two dimensional 'Jeu de Jacquet' detector. In the case of this latter detector, only the hoped for characteristics are indicated [fr

  7. Accuracy of computed tomographic intravenous cholangiography (CT-IVC) with iotroxate in the detection of choledocholithiasis

    International Nuclear Information System (INIS)

    Gibson, Robert N.; Vincent, Janette M.; Speer, Tony; Noack, Keith; Collier, Neil A.

    2005-01-01

    To determine the accuracy of computed tomographic intravenous cholangiography (CT-IVC) for detection of choledocholithiasis. Sixty-five patients undergoing endoscopic retrograde cholangiography (ERC) underwent CT-IVC prior to ERC, using a single detector helical CT following intravenous infusion of 100 ml iotroxate. Patients with bilirubin levels >3 times normal were excluded. ERC was indeterminate in three patients (4.7%) and CT-IVC in four (6.3%). Twenty-three patients had ductal calculi at ERC, and CT-IVC was positive in 22, with two false positives and one false negative: sensitivity 95.6%, specificity 94.3%. Stones were multiple in nine and solitary in 14. Of the 14 solitary stones, ten were ≤5 mm and eight were ≤4 mm. The bilirubin level in positive cases was within normal in 20. Maximum intensity projection (MIP) reformats showed stones in only 27% of cases and surface rendered (SR) reformats in none. CT-IVC is highly accurate for detection of ductal calculi, including single small calculi, with a normal or near normal serum bilirubin. Axial images should be used for interpretation rather than MIP or SR reformats. (orig.)

  8. Accuracy Analysis Comparison of Supervised Classification Methods for Anomaly Detection on Levees Using SAR Imagery

    Directory of Open Access Journals (Sweden)

    Ramakalavathi Marapareddy

    2017-10-01

    Full Text Available This paper analyzes the use of a synthetic aperture radar (SAR imagery to support levee condition assessment by detecting potential slide areas in an efficient and cost-effective manner. Levees are prone to a failure in the form of internal erosion within the earthen structure and landslides (also called slough or slump slides. If not repaired, slough slides may lead to levee failures. In this paper, we compare the accuracy of the supervised classification methods minimum distance (MD using Euclidean and Mahalanobis distance, support vector machine (SVM, and maximum likelihood (ML, using SAR technology to detect slough slides on earthen levees. In this work, the effectiveness of the algorithms was demonstrated using quad-polarimetric L-band SAR imagery from the NASA Jet Propulsion Laboratory’s (JPL’s uninhabited aerial vehicle synthetic aperture radar (UAVSAR. The study area is a section of the lower Mississippi River valley in the Southern USA, where earthen flood control levees are maintained by the US Army Corps of Engineers.

  9. Detection of residual packets in cocaine body packers: low accuracy of abdominal radiography - a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Rousset, Pascal; Vadrot, Dominique; Revel, Marie-Pierre [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Hotel Dieu, Department of Radiology, Paris (France); Universite Paris-Descartes, Paris (France); Chaillot, Pierre-Fleury [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Hotel Dieu, Department of Radiology, Paris (France); Audureau, Etienne [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Hotel Dieu, Department of Biostatistics and Epidemiology, Paris (France); Universite Paris-Descartes, Paris (France); Rey-Salmon, Caroline; Becour, Bertrand [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Hotel Dieu, Department of Forensic, Paris (France); Fitton, Isabelle [Assistance Publique-Hopitaux de Paris, Paris (France); Hopital Europeen Georges Pompidou, Department of Radiology, Paris (France)

    2013-08-15

    To evaluate the accuracy of abdominal radiography (AXR) for the detection of residual cocaine packets by comparison with computed tomography (CT). Over a 1-year period unenhanced CT was systematically performed in addition to AXR for pre-discharge evaluation of cocaine body packers. AXR and CT were interpreted independently by two radiologists blinded to clinical outcome. Patient and packet characteristics were compared between the groups with residual portage and complete decontamination. Among 138 body packers studied, 14 (10 %) had one residual packet identified on pre-discharge CT. On AXR, at least one reader failed to detect the residual packet in 10 (70 %) of these 14 body packers. The sensitivity and specificity of AXR were 28.6 % (95 % CI: 8.4-58.1) and 100.0 % (95 % CI: 97.0-100.0) for reader 1 and 35.7 % (95 % CI: 12.8-64.9) and 97.6 % (95 % CI: 93.1-99.5) for reader 2. There were no significant patient or packet characteristics predictive of residual portage or AXR false negativity. All positive CT results were confirmed by delayed expulsion or surgical findings, while negative results were confirmed by further surveillance. Given the poor performance of AXR, CT should be systematically performed to ensure safe hospital discharge of cocaine body packers. (orig.)

  10. Detection of residual packets in cocaine body packers: low accuracy of abdominal radiography - a prospective study

    International Nuclear Information System (INIS)

    Rousset, Pascal; Vadrot, Dominique; Revel, Marie-Pierre; Chaillot, Pierre-Fleury; Audureau, Etienne; Rey-Salmon, Caroline; Becour, Bertrand; Fitton, Isabelle

    2013-01-01

    To evaluate the accuracy of abdominal radiography (AXR) for the detection of residual cocaine packets by comparison with computed tomography (CT). Over a 1-year period unenhanced CT was systematically performed in addition to AXR for pre-discharge evaluation of cocaine body packers. AXR and CT were interpreted independently by two radiologists blinded to clinical outcome. Patient and packet characteristics were compared between the groups with residual portage and complete decontamination. Among 138 body packers studied, 14 (10 %) had one residual packet identified on pre-discharge CT. On AXR, at least one reader failed to detect the residual packet in 10 (70 %) of these 14 body packers. The sensitivity and specificity of AXR were 28.6 % (95 % CI: 8.4-58.1) and 100.0 % (95 % CI: 97.0-100.0) for reader 1 and 35.7 % (95 % CI: 12.8-64.9) and 97.6 % (95 % CI: 93.1-99.5) for reader 2. There were no significant patient or packet characteristics predictive of residual portage or AXR false negativity. All positive CT results were confirmed by delayed expulsion or surgical findings, while negative results were confirmed by further surveillance. Given the poor performance of AXR, CT should be systematically performed to ensure safe hospital discharge of cocaine body packers. (orig.)

  11. Assessment of the accuracy of AortaScan for detection of abdominal aortic aneurysm (AAA).

    Science.gov (United States)

    Abbas, A; Smith, A; Cecelja, M; Waltham, M

    2012-02-01

    AortaScan AMI 9700 is a portable 3D ultrasound device that automatically measures the maximum diameter of the abdominal aorta without the need for a trained sonographer. It is designed to rapidly diagnose or exclude an AAA and may have particular use in screening programs. Our objective was to determine its accuracy to detect AAA. Subjects from our AAA screening and surveillance programs were examined. The aorta was scanned using the AortaScan and computed tomography (CT). Ninety-one subjects underwent imaging (44 AAA on conventional ultrasound surveillance and 47 controls). The largest measurement obtained by AortaScan was compared against the CT-aortic measurement. The mean aortic diameter was 2.8 cm. The CT scan confirmed the diagnosis of AAA in 43 subjects. There was one false positive measurement on conventional ultrasound. AortaScan missed the diagnosis of AAA in eight subjects. There were thirteen false positive measurements. The sensitivity, specificity, positive and negative predictive values were 81%, 72%, 72% and 81% respectively. A device to detect AAA without the need for a trained operator would have potential in a community-based screening programme. The AortaScan, however, lacks adequate sensitivity and significant technical improvement is necessary before it could be considered a replacement for trained screening personnel. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  12. Diagnostic accuracy of 18F-FDG PET/CT for detection of advanced colorectal adenoma

    International Nuclear Information System (INIS)

    Gollub, M.J.; Grewal, R.K.; Panu, N.; Thipphavong, S.; Sohn, M.; Zheng, J.; Moskowitz, C.S.

    2014-01-01

    Aim: To determine the accuracy of 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography (PET) in the detection of advanced colorectal adenomas. Materials and methods: In this retrospective study, patient consent was waived by the institutional review board. Combined FDG whole-body PET and computed tomography (CT) images (2000–2009) were re-read and compared with reports of complete colonoscopy performed up to 1 year after the PET examination. One or more areas of focal colonic uptake greater than the background indicated a positive PET result, irrespective of standardized uptake value (SUV). Lesion and patient-level measures of PET accuracy with their 95% confidence intervals (CI) were calculated. Results: One hundred and eighty patients undergoing colonoscopy with or without biopsy underwent PET within 1 year prior to colonoscopy. There were 92 women and 88 men (mean age 63.3 years). Indications for PET were extent of disease and treatment response in all cases. Patients had non-colorectal cancer (n = 160) or colon cancer (n = 20). One hundred and fourteen FDG-avid lesions were present. In 33, there was no colonoscopic correlate. Two hundred and fifty-eight biopsies revealed tubular adenomas (n = 91, one with intra-mucosal cancer), tubulovillous adenomas (n = 28), adenocarcinoma (n = 37), inflammation (n = 22), hyperplastic polyps (n = 54), serrated adenoma (n = 5), metastatic disease (n = 5), normal/benign mucosa or submucosal benign tumors (n = 13) or miscellaneous (n = 3). Per-lesion performance of PET showed a sensitivity of 38% (95% CI: 31–46; 64/167) for all adenomas and carcinomas and 58% (95% CI: 49–67; 57/98) for lesions ≥10 mm. At the patient level, for all adenomas and carcinomas the sensitivity was 54% (95% CI: 44–63; 61/113), specificity 100% (pre-defined), positive predictive value (PPV) 100% (pre-defined), and negative predictive value (NPV) 56% (95% CI: 47–65; 67/119). For patients with advanced

  13. Diagnostic Accuracy of a Novel Mobile Phone Application for the Detection and Monitoring of Atrial Fibrillation.

    Science.gov (United States)

    Rozen, Guy; Vaid, Jeena; Hosseini, Seyed Mohammadreza; Kaadan, M Ihsan; Rafael, Allon; Roka, Attila; Poh, Yukkee C; Poh, Ming-Zher; Heist, Edwin Kevin; Ruskin, Jeremy Neil

    2018-05-15

    Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in adults, associated with significant morbidity, increased mortality, and rising health-care costs. Simple and available tools for the accurate detection of arrhythmia recurrence in patients after electrical cardioversion (CV) or ablation procedures for AF can help to guide therapeutic decisions. We conducted a prospective, single-center study to evaluate the accuracy of Cardiio Rhythm Mobile Application (CRMA) for AF detection. Patients >18 years of age who were scheduled for elective CV for AF were enrolled in the study. CRMA finger pulse recordings, utilizing an iPhone camera, were obtained before (pre-CV) and after (post-CV) the CV. The findings were validated against surface electrocardiograms. Ninety-eight patients (75.5% men), mean age of 67.7 ± 10.5 years, were enrolled. No electrocardiogram for validation was available in 1 case. Pre-CV CRMA readings were analyzed in 97 of the 98 patients. Post-CV CRMA readings were analyzed for 92 of 93 patients who underwent CV. One patient left before the recording was obtained. The Cardiio Rhythm Mobile Application correctly identified 94 of 101 AF recordings (93.1%) as AF and 80 of 88 non-AF recordings (90.1%) as non-AF. The sensitivity was 93.1% (95% confidence interval [CI] = 86.9% to 97.2%) and the specificity was 90.9% (95% CI = 82.9% to 96.0%). The positive predictive value was 92.2% (95% CI = 85.8% to 95.8%) and the negative predictive value was 92.0% (95% CI = 94.8% to 95.9%). In conclusion, the CRMA demonstrates promising potential in accurate detection and discrimination of AF from normal sinus rhythm in patients with a history of AF. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. The diagnostic accuracy of endovaginal and transperineal ultrasound for detecting anal sphincter defects: The PREDICT study.

    Science.gov (United States)

    Roos, A-M; Abdool, Z; Sultan, A H; Thakar, R

    2011-07-01

    To determine the accuracy and predictive value of transperineal (TPU) and endovaginal ultrasound (EVU) in the detection of anal sphincter defects in women with obstetric anal sphincter injuries and/or postpartum symptoms of faecal incontinence. One hundred and sixty-five women were recruited, four women were excluded as they were seen years after their last delivery. TPU and EVU, followed by endonanal ultrasound (EAU), were performed using the B&K Viking 2400 scanner. Sensitivity and specificity, as well as predictive values with 95% confidence intervals, for detecting anal sphincter defects were calculated for EVU and TPU, using EAU as the reference standard. On EAU a defect was found in 42 (26%) women: 39 (93%) had an external (EAS) and 23 (55%) an internal anal sphincter (IAS) defect. Analysable images of one level of the EAS combined with an analysable IAS were available in 140 (87%) women for EVU and in 131 (81%) for TPU. The sensitivity and specificity for the detection of any defect was 48% (30-67%) and 85% (77-91%) for EVU and 64% (44-81%) and 85% (77-91%) for TPU, respectively. Although EAU using a rotating endoprobe is the validated reference standard in the identification of anal sphincter defects, it is not universally available. However while TPU and/or EVU with conventional ultrasound probes can be useful in identifying normality, for clinical purposes they are not sensitive enough to identify an underlying sphincter defect. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  15. The Accuracy of Pulse Spectroscopy for Detecting Hypoxemia and Coexisting Methemoglobin or Carboxyhemoglobin.

    Science.gov (United States)

    Kulcke, Axel; Feiner, John; Menn, Ingolf; Holmer, Amadeus; Hayoz, Josef; Bickler, Philip

    2016-06-01

    Pulse spectroscopy is a new noninvasive technology involving hundreds of wavelengths of visible and infrared light, enabling the simultaneous quantitation of multiple types of normal and dysfunctional hemoglobin. We evaluated the accuracy of a first-generation pulse spectroscopy system (V-Spec™ Monitoring System, Senspec, Germany) in measuring oxygen saturation (SpO2) and detecting carboxyhemoglobin (COHb) or methemoglobin (MetHb), alone or simultaneously, with hypoxemia. Nineteen volunteers were fitted with V-Spec probes on the forehead and fingers. A radial arterial catheter was placed for blood sampling during (1) hypoxemia with arterial oxygen saturations (SaO2) of 100% to 58.5%; (2) normoxia with MetHb and COHb increased to approximately 10%; (3) 10% COHb or MetHb combined with hypoxemia with SaO2 of 100% to 80%. Standard measures of pulse-oximetry performance were calculated: bias (pulse spectroscopy measured value - arterial measured value) mean ± SD and root-mean-square error (Arms). The SpO2 bias for SaO2 approximately 60% to 100% was 0.06% ± 1.30% and Arms of 1.30%. COHb bias was 0.45 ± 1.63, with an Arms of 1.69% overall, and did not degrade substantially during moderate hypoxemia. MetHb bias was 0.36 ± 0.80 overall and stayed small with hypoxemia. Arms was 0.88 and was 10%. Pulse spectroscopy accurately detects hypoxemia, MetHb, and COHb. The technology also accurately detects these dysfunctional hemoglobins during hypoxemia. Future releases of this device may have an improved SpO2 algorithm that is more robust with methemoglobinemia.

  16. Accuracy Enhancement with Processing Error Prediction and Compensation of a CNC Flame Cutting Machine Used in Spatial Surface Operating Conditions

    Directory of Open Access Journals (Sweden)

    Shenghai Hu

    2017-04-01

    Full Text Available This study deals with the precision performance of the CNC flame-cutting machine used in spatial surface operating conditions and presents an accuracy enhancement method based on processing error modeling prediction and real-time compensation. Machining coordinate systems and transformation matrix models were established for the CNC flame processing system considering both geometric errors and thermal deformation effects. Meanwhile, prediction and compensation models were constructed related to the actual cutting situation. Focusing on the thermal deformation elements, finite element analysis was used to measure the testing data of thermal errors, the grey system theory was applied to optimize the key thermal points, and related thermal dynamics models were carried out to achieve high-precision prediction values. Comparison experiments between the proposed method and the teaching method were conducted on the processing system after performing calibration. The results showed that the proposed method is valid and the cutting quality could be improved by more than 30% relative to the teaching method. Furthermore, the proposed method can be used under any working condition by making a few adjustments to the prediction and compensation models.

  17. Creation and detection of optical modes with spatial light modulators

    CSIR Research Space (South Africa)

    Forbes, A

    2016-06-01

    Full Text Available (1979). 24. J. A. Davis, K. O. Valade´z, and D. M. Cottrell, “Encoding amplitude and phase information onto a binary phase-only spatial light modulator,” Appl. Opt. 42, 2003–2008 (2003). 25. E. Bolduc, N. Bent, E. Santamato, E. Karimi, and R. W. Boyd...

  18. Rapid Fear Detection Relies on High Spatial Frequencies

    NARCIS (Netherlands)

    Stein, T.; Seymour, K.; Hebart, M.N.; Sterzer, P.

    Signals of threat—such as fearful faces—are processed with priority and have privileged access to awareness. This fear advantage is commonly believed to engage a specialized subcortical pathway to the amygdala that bypasses visual cortex and processes predominantly low-spatial-frequency information

  19. Evaluating the accuracy of low cost UAV generated topography and its effectiveness for geomorphic change detection

    Science.gov (United States)

    Cook, Kristen

    2015-04-01

    With the recent explosion in the use and availability of unmanned aerial vehicle platforms and development of easy to use structure from motion (SfM) software, UAV based photogrammetry is increasingly being adopted to produce high resolution topography for the study of surface processes. UAV systems can vary substantially in price and complexity, but the tradeoffs between these and the quality of the resulting data are not well constrained. We look at one end of this spectrum and evaluate the effectiveness of a simple low cost UAV setup for obtaining high resolution topography in a challenging field setting. Our study site is the Daan River gorge in western Taiwan, a rapidly eroding bedrock gorge that we have monitored with terrestrial Lidar since 2009. The site presents challenges for the generation and analysis of high resolution topography, including vertical gorge walls, vegetation, wide variation in surface roughness, and a complicated 3D morphology. In order to evaluate the accuracy of the UAV-derived topography, we compare it with terrestrial Lidar data collected during the same survey period. Our UAV setup combines a DJI Phantom 2 quadcopter with a 16 megapixel Canon Powershot camera for a total platform cost of less than 850. The quadcopter is flown manually, and the camera is programmed to take a photograph every 4 seconds, yielding 200-250 pictures per flight. We measured ground control points and targets for both the Lidar scans and the aerial surveys using a Leica RTK GPS with 1-2 cm accuracy. UAV derived point clouds were obtained using Agisoft Photoscan software. We conducted both Lidar and UAV surveys before and after the 2014 typhoon season, allowing us to evaluate the reliability of the UAV survey to detect geomorphic changes in the range of one to several meters. The accuracy of the SfM point clouds depends strongly on the characteristics of the surface being considered, with vegetation and small scale texture causing inaccuracies. However, we

  20. Detection of precursory deformation using a TLS. Application to spatial prediction of rockfalls.

    Science.gov (United States)

    Abellán, Antonio; Vilaplana, Joan Manuel; Calvet, Jaume; Rodriguez, Xavier

    2010-05-01

    Different applications on the use of Terrestrial Laser Scanner (TLS) on rock slopes are undergoing rapid development, mainly in the characterization of 3D discontinuities and the monitoring of rock slopes. The emphasis of this research is on detection of precursory deformation and its application to spatial prediction of rockfalls. The pilot study area corresponds to the main scarp of an old slide located at Puigcercós (Catalonia, Spain). 3D temporal variations of the terrain were analyzed by comparing sequential TLS datasets. Five areas characterized by centimetric precursory deformations were detected in the study area. Of these deformations, (a) growing deformation across three areas culminated in a rockfall occurrence; and (b) another growing deformation across two areas was detected, making a subsequent rockfall likely. The areas with precursory deformations detected in Puigcercós showed the following characteristics: (a) a sub-vertical fracture delimiting the moving part from the rest of the slope; (b) an increase in the horizontal displacement upwards, typical of a toppling failure mechanism (Muller 1968; Goodman and Bray, 1976). In addition, decimetric-scale rockfalls were observed in the upper part of the moving areas, which is consistent with the observations of Rosser et al., (2007). TLS ILRIS 3D technical characteristics are as follows: high accuracy (7.2 mm at a range of 50 meters), high angular resolution (e.g. 1 point every few cm), fast data acquisition: 2,500 points/second; broad coverage; high maximum range on natural slopes: ~600m. The single point distances between the surface of reference and the successive data point clouds were computed using a conventional methodology (data vs. reference comparison). The direction of comparison was defined as the normal vector of the rock face at its central part. We focused in the study of the small scale displacements towards the origin of coordinates, which reflect the pre-failure deformation on part of

  1. Accuracy of computed tomography-intravenous cholangiography (CT-IVC) in detection of choledocholithiasis)

    International Nuclear Information System (INIS)

    Gibson, R.; Speer, A.G.; Collier, N.A.; Vincent, J.M.; Jardine, C.; Noack, K.

    2002-01-01

    Full text: The aim of the study was to determine the accuracy of computed tomography-intravenous cholangiography (CT-IVC) in the detection of choledocholithiasis, compared with endoscopic retrograde cholangiography (ERC). 65 patients undergoing ERC had CT-IVC within 24 hours prior to ERC. Helical CT-IVC was performed following intravenous infusion of 100ml Biliscopin (Schering, Berlin). 2mm beam collimation was used with axial reformats at 1.5mm intervals used for image interpretation. Patients with serum bilirubin levels>3 times normal were excluded. CT-IVC and ERC studies were interpreted independently, and studies were graded as positive, negative or indeterminate for the presence of ductal calculi. 65 patients had a median age of 56 years. Median serum bilirubin at the time of CT-IVC was 13 mmol/L (range 5-47). ERC was indeterminate in 3 patients (4.7%) and CT-IVC in 4 (6.3%). 23 patients had ductal calculi on ERC and CT-IVC was positive in 22 (sensitivity 96%). False positive rate for CT-IVC was 8.3% with positive and negative predictive values of 92% and 97% respectively. Stones' size range was 4-16mm. Of the 14 solitary stones, 10 were pound 5mm and 8 pound 4mm.The bilirubin level in the positive cases was within the normal range in 20, with a range of 7-37 mmol/L. CT-IVC is highly accurate for detection of ductal calculi, including single small calculi, in patients with a serum bilirubin of <3 times normal. Copyright (2002) Blackwell Science Pty Ltd

  2. Diagnostic accuracy of tablet-based software for the detection of concussion.

    Science.gov (United States)

    Yang, Suosuo; Flores, Benjamin; Magal, Rotem; Harris, Kyrsti; Gross, Jonathan; Ewbank, Amy; Davenport, Sasha; Ormachea, Pablo; Nasser, Waleed; Le, Weidong; Peacock, W Frank; Katz, Yael; Eagleman, David M

    2017-01-01

    Despite the high prevalence of traumatic brain injuries (TBI), there are few rapid and straightforward tests to improve its assessment. To this end, we developed a tablet-based software battery ("BrainCheck") for concussion detection that is well suited to sports, emergency department, and clinical settings. This article is a study of the diagnostic accuracy of BrainCheck. We administered BrainCheck to 30 TBI patients and 30 pain-matched controls at a hospital Emergency Department (ED), and 538 healthy individuals at 10 control test sites. We compared the results of the tablet-based assessment against physician diagnoses derived from brain scans, clinical examination, and the SCAT3 test, a traditional measure of TBI. We found consistent distributions of normative data and high test-retest reliability. Based on these assessments, we defined a composite score that distinguishes TBI from non-TBI individuals with high sensitivity (83%) and specificity (87%). We conclude that our testing application provides a rapid, portable testing method for TBI.

  3. Diagnostic accuracy of tablet-based software for the detection of concussion.

    Directory of Open Access Journals (Sweden)

    Suosuo Yang

    Full Text Available Despite the high prevalence of traumatic brain injuries (TBI, there are few rapid and straightforward tests to improve its assessment. To this end, we developed a tablet-based software battery ("BrainCheck" for concussion detection that is well suited to sports, emergency department, and clinical settings. This article is a study of the diagnostic accuracy of BrainCheck. We administered BrainCheck to 30 TBI patients and 30 pain-matched controls at a hospital Emergency Department (ED, and 538 healthy individuals at 10 control test sites. We compared the results of the tablet-based assessment against physician diagnoses derived from brain scans, clinical examination, and the SCAT3 test, a traditional measure of TBI. We found consistent distributions of normative data and high test-retest reliability. Based on these assessments, we defined a composite score that distinguishes TBI from non-TBI individuals with high sensitivity (83% and specificity (87%. We conclude that our testing application provides a rapid, portable testing method for TBI.

  4. Diagnostic accuracy of a novel software technology for detecting pneumothorax in a porcine model.

    Science.gov (United States)

    Summers, Shane M; Chin, Eric J; April, Michael D; Grisell, Ronald D; Lospinoso, Joshua A; Kheirabadi, Bijan S; Salinas, Jose; Blackbourne, Lorne H

    2017-09-01

    Our objective was to measure the diagnostic accuracy of a novel software technology to detect pneumothorax on Brightness (B) mode and Motion (M) mode ultrasonography. Ultrasonography fellowship-trained emergency physicians performed thoracic ultrasonography at baseline and after surgically creating a pneumothorax in eight intubated, spontaneously breathing porcine subjects. Prior to pneumothorax induction, we captured sagittal M-mode still images and B-mode videos of each intercostal space with a linear array transducer at 4cm of depth. After collection of baseline images, we placed a chest tube, injected air into the pleural space in 250mL increments, and repeated the ultrasonography for pneumothorax volumes of 250mL, 500mL, 750mL, and 1000mL. We confirmed pneumothorax with intrapleural digital manometry and ultrasound by expert sonographers. We exported collected images for interpretation by the software. We treated each individual scan as a single test for interpretation by the software. Excluding indeterminate results, we collected 338M-mode images for which the software demonstrated a sensitivity of 98% (95% confidence interval [CI] 92-99%), specificity of 95% (95% CI 86-99), positive likelihood ratio (LR+) of 21.6 (95% CI 7.1-65), and negative likelihood ratio (LR-) of 0.02 (95% CI 0.008-0.046). Among 364 B-mode videos, the software demonstrated a sensitivity of 86% (95% CI 81-90%), specificity of 85% (81-91%), LR+ of 5.7 (95% CI 3.2-10.2), and LR- of 0.17 (95% CI 0.12-0.22). This novel technology has potential as a useful adjunct to diagnose pneumothorax on thoracic ultrasonography. Published by Elsevier Inc.

  5. Classification Accuracy of MMPI-2 Validity Scales in the Detection of Pain-Related Malingering: A Known-Groups Study

    Science.gov (United States)

    Bianchini, Kevin J.; Etherton, Joseph L.; Greve, Kevin W.; Heinly, Matthew T.; Meyers, John E.

    2008-01-01

    The purpose of this study was to determine the accuracy of "Minnesota Multiphasic Personality Inventory" 2nd edition (MMPI-2; Butcher, Dahlstrom, Graham, Tellegen, & Kaemmer, 1989) validity indicators in the detection of malingering in clinical patients with chronic pain using a hybrid clinical-known groups/simulator design. The…

  6. Accuracy of imaging methods for detection of bone tissue invasion in patients with oral squamous cell carcinoma

    Science.gov (United States)

    Uribe, S; Rojas, LA; Rosas, CF

    2013-01-01

    The objective of this review is to evaluate the diagnostic accuracy of imaging methods for detection of mandibular bone tissue invasion by squamous cell carcinoma (SCC). A systematic review was carried out of studies in MEDLINE, SciELO and ScienceDirect, published between 1960 and 2012, in English, Spanish or German, which compared detection of mandibular bone tissue invasion via different imaging tests against a histopathology reference standard. Sensitivity and specificity data were extracted from each study. The outcome measure was diagnostic accuracy. We found 338 articles, of which 5 fulfilled the inclusion criteria. Tests included were: CT (four articles), MRI (four articles), panoramic radiography (one article), positron emission tomography (PET)/CT (one article) and cone beam CT (CBCT) (one article). The quality of articles was low to moderate and the evidence showed that all tests have a high diagnostic accuracy for detection of mandibular bone tissue invasion by SCC, with sensitivity values of 94% (MRI), 91% (CBCT), 83% (CT) and 55% (panoramic radiography), and specificity values of 100% (CT, MRI, CBCT), 97% (PET/CT) and 91.7% (panoramic radiography). Available evidence is scarce and of only low to moderate quality. However, it is consistently shown that current imaging methods give a moderate to high diagnostic accuracy for the detection of mandibular bone tissue invasion by SCC. Recommendations are given for improving the quality of future reports, in particular provision of a detailed description of the patients' conditions, the imaging instrument and both imaging and histopathological invasion criteria. PMID:23420854

  7. Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation

    International Nuclear Information System (INIS)

    Addley, H.C.; Griffin, N.; Shaw, A.S.; Mannelli, L.; Parker, R.A.; Aitken, S.; Wood, H.; Davies, S.; Alexander, G.J.; Lomas, D.J.

    2011-01-01

    Aim: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for hepatocellular carcinoma (HCC) in cirrhotic patients undergoing liver transplantation. Secondary aims were to examine the effect of radiologist experience and lesion size on diagnostic accuracy. Materials and methods: Thirty-nine patients (72% male with a mean age of 56.5 years) underwent liver transplantation following preoperative triple-phase MDCT examination of the liver. MDCT examinations were retrospectively independently reviewed by three radiologists for the presence and location of suspected HCCs, with the diagnostic confidence recorded using a five-point confidence scale. MDCT examinations were compared with explant specimens for histopathological correlation. Results: Histopathological results demonstrated 46 HCCs in 29 of the 39 patients. Analysis demonstrated a sensitivity of 65-75% and specificity of 47-88% for detection of HCC lesions. The sensitivity dropped to 48-57% for lesions of size ≤20 mm. As the diagnostic confidence increased, there was a further decrease in the sensitivity (4-26%). The radiologist with the greatest number of years experience was found to have a significantly higher accuracy of detection of HCC lesions compared with the least experienced radiologist. Conclusion: Larger lesion size of HCC and greater number of years experience of the radiologist resulted in significantly higher accuracy of HCC lesion detection. The overall sensitivity and specificity results for MDCT detection of HCC are comparable to previous helical CT imaging.

  8. Minimum detection limit and spatial resolution of thin-sample field-emission electron probe microanalysis

    International Nuclear Information System (INIS)

    Kubo, Yugo; Hamada, Kotaro; Urano, Akira

    2013-01-01

    The minimum detection limit and spatial resolution for a thinned semiconductor sample were determined by electron probe microanalysis (EPMA) using a Schottky field emission (FE) electron gun and wavelength dispersive X-ray spectrometry. Comparison of the FE-EPMA results with those obtained using energy dispersive X-ray spectrometry in conjunction with scanning transmission electron microscopy, confirmed that FE-EPMA is largely superior in terms of detection sensitivity. Thin-sample FE-EPMA is demonstrated as a very effective method for high resolution, high sensitivity analysis in a laboratory environment because a high probe current and high signal-to-noise ratio can be achieved. - Highlights: • Minimum detection limit and spatial resolution determined for FE-EPMA. • Detection sensitivity of FE-EPMA greatly superior to that of STEM-EDX. • Minimum detection limit and spatial resolution controllable by probe current

  9. Detection of endolithic spatial distribution in marble stone.

    Science.gov (United States)

    Casanova Municchia, A; Percario, Z; Caneva, G

    2014-10-01

    The penetration of endolithic microorganisms, which develop to depths of several millimetres or even centimetres into the stone, and the diffusion of their extracellular substances speeds up the stone deterioration process. The aim of this study was to investigate, using a confocal laser scanning microscopy with a double-staining, a marble rock sample by observing the endolithic spatial distribution and quantifying the volume they occupied within the stone, in order to understand the real impact of these microorganisms on the conservation of stone monuments. Often the only factors taken into account by biodeterioration studies regarding endolithic microorganisms, are spread and depth of penetration. Despite the knowledge of three-dimensional spatial distribution and quantification of volume, it is indispensable to understand the real damage caused by endolithic microorganisms to stone monuments. In this work, we analyze a marble rock sample using a confocal laser scanning microscopy stained with propidium iodide and Concavalin-A conjugate with the fluorophore Alexa Fluor 488, comparing these results with other techniques (SEM microscope, microphotographs of polished cross-sections and thin-section, PAS staining methods), An image analysis approach has also been applied. The use of confocal laser scanning microscopy with double staining shows clear evidence of the presence of endolithic microorganisms (cyanobacteria and fungi) as well as the extracellular polymeric substance matrix in a three-dimensional architecture as part of the rock sample, this technique, therefore, seems very useful when applied to restoration interventions on stone monuments when endolithic growth is suspected. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  10. Locating sensors for detecting source-to-target patterns of special nuclear material smuggling: a spatial information theoretic approach.

    Science.gov (United States)

    Przybyla, Jay; Taylor, Jeffrey; Zhou, Xuesong

    2010-01-01

    In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM) smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy.

  11. Locating Sensors for Detecting Source-to-Target Patterns of Special Nuclear Material Smuggling: A Spatial Information Theoretic Approach

    Directory of Open Access Journals (Sweden)

    Xuesong Zhou

    2010-08-01

    Full Text Available In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy.

  12. Detecting abrupt dynamic change based on changes in the fractal properties of spatial images

    Science.gov (United States)

    Liu, Qunqun; He, Wenping; Gu, Bin; Jiang, Yundi

    2017-10-01

    Many abrupt climate change events often cannot be detected timely by conventional abrupt detection methods until a few years after these events have occurred. The reason for this lag in detection is that abundant and long-term observational data are required for accurate abrupt change detection by these methods, especially for the detection of a regime shift. So, these methods cannot help us understand and forecast the evolution of the climate system in a timely manner. Obviously, spatial images, generated by a coupled spatiotemporal dynamical model, contain more information about a dynamic system than a single time series, and we find that spatial images show the fractal properties. The fractal properties of spatial images can be quantitatively characterized by the Hurst exponent, which can be estimated by two-dimensional detrended fluctuation analysis (TD-DFA). Based on this, TD-DFA is used to detect an abrupt dynamic change of a coupled spatiotemporal model. The results show that the TD-DFA method can effectively detect abrupt parameter changes in the coupled model by monitoring the changing in the fractal properties of spatial images. The present method provides a new way for abrupt dynamic change detection, which can achieve timely and efficient abrupt change detection results.

  13. A flexible spatial scan statistic with a restricted likelihood ratio for detecting disease clusters.

    Science.gov (United States)

    Tango, Toshiro; Takahashi, Kunihiko

    2012-12-30

    Spatial scan statistics are widely used tools for detection of disease clusters. Especially, the circular spatial scan statistic proposed by Kulldorff (1997) has been utilized in a wide variety of epidemiological studies and disease surveillance. However, as it cannot detect noncircular, irregularly shaped clusters, many authors have proposed different spatial scan statistics, including the elliptic version of Kulldorff's scan statistic. The flexible spatial scan statistic proposed by Tango and Takahashi (2005) has also been used for detecting irregularly shaped clusters. However, this method sets a feasible limitation of a maximum of 30 nearest neighbors for searching candidate clusters because of heavy computational load. In this paper, we show a flexible spatial scan statistic implemented with a restricted likelihood ratio proposed by Tango (2008) to (1) eliminate the limitation of 30 nearest neighbors and (2) to have surprisingly much less computational time than the original flexible spatial scan statistic. As a side effect, it is shown to be able to detect clusters with any shape reasonably well as the relative risk of the cluster becomes large via Monte Carlo simulation. We illustrate the proposed spatial scan statistic with data on mortality from cerebrovascular disease in the Tokyo Metropolitan area, Japan. Copyright © 2012 John Wiley & Sons, Ltd.

  14. Spatial frequency characteristics at image decision-point locations for observers with different radiological backgrounds in lung nodule detection

    Science.gov (United States)

    Pietrzyk, Mariusz W.; Manning, David J.; Dix, Alan; Donovan, Tim

    2009-02-01

    Aim: The goal of the study is to determine the spatial frequency characteristics at locations in the image of overt and covert observers' decisions and find out if there are any similarities in different observers' groups: the same radiological experience group or the same accuracy scored level. Background: The radiological task is described as a visual searching decision making procedure involving visual perception and cognitive processing. Humans perceive the world through a number of spatial frequency channels, each sensitive to visual information carried by different spatial frequency ranges and orientations. Recent studies have shown that particular physical properties of local and global image-based elements are correlated with the performance and the level of experience of human observers in breast cancer and lung nodule detections. Neurological findings in visual perception were an inspiration for wavelet applications in vision research because the methodology tries to mimic the brain processing algorithms. Methods: The wavelet approach to the set of postero-anterior chest radiographs analysis has been used to characterize perceptual preferences observers with different levels of experience in the radiological task. Psychophysical methodology has been applied to track eye movements over the image, where particular ROIs related to the observers' fixation clusters has been analysed in the spaces frame by Daubechies functions. Results: Significance differences have been found between the spatial frequency characteristics at the location of different decisions.

  15. Importance of spatial and spectral data reduction in the detection of internal defects in food products.

    Science.gov (United States)

    Zhang, Xuechen; Nansen, Christian; Aryamanesh, Nader; Yan, Guijun; Boussaid, Farid

    2015-04-01

    Despite the importance of data reduction as part of the processing of reflection-based classifications, this study represents one of the first in which the effects of both spatial and spectral data reductions on classification accuracies are quantified. Furthermore, the effects of approaches to data reduction were quantified for two separate classification methods, linear discriminant analysis (LDA) and support vector machine (SVM). As the model dataset, reflection data were acquired using a hyperspectral camera in 230 spectral channels from 401 to 879 nm (spectral resolution of 2.1 nm) from field pea (Pisum sativum) samples with and without internal pea weevil (Bruchus pisorum) infestation. We deployed five levels of spatial data reduction (binning) and eight levels of spectral data reduction (40 datasets). Forward stepwise LDA was used to select and include only spectral channels contributing the most to the separation of pixels from non-infested and infested field peas. Classification accuracies obtained with LDA and SVM were based on the classification of independent validation datasets. Overall, SVMs had significantly higher classification accuracies than LDAs (P food products with internal defects, and it highlights that spatial and spectral data reductions can (1) improve classification accuracies, (2) vastly decrease computer constraints, and (3) reduce analytical concerns associated with classifications of large and high-dimensional datasets.

  16. A spatially offset Raman spectroscopy method for non-destructive detection of gelatin-encapsulated powders

    Science.gov (United States)

    Non-destructive subsurface detection of encapsulated, coated, or seal-packaged foods and pharmaceuticals can help prevent distribution and consumption of counterfeit or hazardous products. This study used a Spatially Offset Raman Spectroscopy (SORS) method to detect and identify urea, ibuprofen, and...

  17. Spatial cluster detection for repeatedly measured outcomes while accounting for residential history.

    Science.gov (United States)

    Cook, Andrea J; Gold, Diane R; Li, Yi

    2009-10-01

    Spatial cluster detection has become an important methodology in quantifying the effect of hazardous exposures. Previous methods have focused on cross-sectional outcomes that are binary or continuous. There are virtually no spatial cluster detection methods proposed for longitudinal outcomes. This paper proposes a new spatial cluster detection method for repeated outcomes using cumulative geographic residuals. A major advantage of this method is its ability to readily incorporate information on study participants relocation, which most cluster detection statistics cannot. Application of these methods will be illustrated by the Home Allergens and Asthma prospective cohort study analyzing the relationship between environmental exposures and repeated measured outcome, occurrence of wheeze in the last 6 months, while taking into account mobile locations.

  18. Spatially resolved detection of mutually locked Josephson junctions in arrays

    International Nuclear Information System (INIS)

    Keck, M.; Doderer, T.; Huebener, R.P.; Traeuble, T.; Dolata, R.; Weimann, T.; Niemeyer, J.

    1997-01-01

    Mutual locking due to the internal coupling in two-dimensional arrays of Josephson junctions was investigated. The appearance of Shapiro steps in the current versus voltage curve of a coupled on-chip detector junction is used to indicate coherent oscillations in the array. A highly coherent state is observed for some range of the array bias current. By scanning the array with a low-power electron beam, mutually locked junctions remain locked while the unlocked junctions generate a beam-induced additional voltage drop at the array. This imaging technique allows the detection of the nonlocked or weakly locked Josephson junctions in a (partially) locked array state. copyright 1997 American Institute of Physics

  19. A method of detecting spatial clustering of disease

    International Nuclear Information System (INIS)

    Openshaw, S.; Wilkie, D.; Binks, K.; Wakeford, R.; Gerrard, M.H.; Croasdale, M.R.

    1989-01-01

    A statistical technique has been developed to identify extreme groupings of a disease and is being applied to childhood cancers, initially to acute lymphoblastic leukaemia incidence in the Northern and North-Western Regions of England. The method covers the area with a square grid, the size of which is varied over a wide range and whose origin is moved in small increments in two directions. The population at risk within any square is estimated using the 1971 and 1981 censuses. The significance of an excess of disease is determined by random simulation. In addition, tests to detect a general departure from a background Poisson process are carried out. Available results will be presented at the conference. (author)

  20. Spatial biomarker of disease and detection of spatial organization of cellular receptors

    Science.gov (United States)

    Salaita, Khalid S.; Nair, Pradeep M.; Das, Debopriya; Gray, Joe W.; Groves, John T.

    2017-07-18

    A signature of a condition of a live cell is established in an assay that allows distribution of the receptors on the cell surface in response to binding a ligand. The receptors can be optically detected and quantified to provide a value for the condition, Test drugs can be screened for therapeutic potential in the assay: a potentially efficacious drug is identified by an ability to modulate an established signature. The receptor distribution signature can be corroborated with an mRNA expression profile of several genes, indicating, for example, metastasis.

  1. Effect of time lapse on the diagnostic accuracy of cone beam computed tomography for detection of vertical root fractures

    Energy Technology Data Exchange (ETDEWEB)

    Eskandarloo, Amir; Shokri, Abbas, E-mail: Dr.a.shokri@gmail.com [Dental Research Center, Department of Oral and Maxillofacial Radiology, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Asl, Amin Mahdavi [Department of Oral and Maxillofacial Radiology, Golestan University of Medical Sciences, Gorgan (Iran, Islamic Republic of); Jalalzadeh, Mohsen [Department of Endodontics, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Tayari, Maryam [Department of Pedodontics, Golestan University of Medical Sciences, Gorgan (Iran, Islamic Republic of); Hosseinipanah, Mohammad [Department of Anatomy, School of Medicine, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of); Fardmal, Javad [Research Center for Health Sciences and Department of Epidemiology and Biostatistics, School of Public Health, Hamadan University of Medical Sciences, Hamadan (Iran, Islamic Republic of)

    2016-01-15

    Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog’s teeth. Forty eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans. (author)

  2. Effect of time lapse on the diagnostic accuracy of cone beam computed tomography for detection of vertical root fractures

    International Nuclear Information System (INIS)

    Eskandarloo, Amir; Shokri, Abbas; Asl, Amin Mahdavi; Jalalzadeh, Mohsen; Tayari, Maryam; Hosseinipanah, Mohammad; Fardmal, Javad

    2016-01-01

    Accurate and early diagnosis of vertical root fractures (VRFs) is imperative to prevent extensive bone loss and unnecessary endodontic and prosthodontic treatments. The aim of this study was to assess the effect of time lapse on the diagnostic accuracy of cone beam computed tomography (CBCT) for VRFs in endodontically treated dog’s teeth. Forty eight incisors and premolars of three adult male dogs underwent root canal therapy. The teeth were assigned to two groups: VRFs were artificially induced in the first group (n=24) while the teeth in the second group remained intact (n=24). The CBCT scans were obtained by NewTom 3G unit immediately after inducing VRFs and after one, two, three, four, eight, 12 and 16 weeks. Three oral and maxillofacial radiologists blinded to the date of radiographs assessed the presence/absence of VRFs on CBCT scans. The sensitivity, specificity and accuracy values were calculated and data were analyzed using SPSS v.16 software and ANOVA. The total accuracy of detection of VRFs immediately after surgery, one, two, three, four, eight, 12 and 16 weeks was 67.3%, 68.7%, 66.6%, 64.6%, 64.5%, 69.4%, 68.7%, 68% respectively. The effect of time lapse on detection of VRFs was not significant (p>0.05). Overall sensitivity, specificity and accuracy of CBCT for detection of VRFs were 74.3%, 62.2%, 67.2% respectively. Cone beam computed tomography is a valuable tool for detection of VRFs. Time lapse (four months) had no effect on detection of VRFs on CBCT scans. (author)

  3. FIND: difFerential chromatin INteractions Detection using a spatial Poisson process.

    Science.gov (United States)

    Djekidel, Mohamed Nadhir; Chen, Yang; Zhang, Michael Q

    2018-02-12

    Polymer-based simulations and experimental studies indicate the existence of a spatial dependency between the adjacent DNA fibers involved in the formation of chromatin loops. However, the existing strategies for detecting differential chromatin interactions assume that the interacting segments are spatially independent from the other segments nearby. To resolve this issue, we developed a new computational method, FIND, which considers the local spatial dependency between interacting loci. FIND uses a spatial Poisson process to detect differential chromatin interactions that show a significant difference in their interaction frequency and the interaction frequency of their neighbors. Simulation and biological data analysis show that FIND outperforms the widely used count-based methods and has a better signal-to-noise ratio. © 2018 Djekidel et al.; Published by Cold Spring Harbor Laboratory Press.

  4. Diagnostic Accuracy of Diffusion Weighted Magnetic Resonance Imaging in the Detection of Myometrial Invasion in Endometrial Carcinoma

    International Nuclear Information System (INIS)

    Masroor, I.; Hussain, Z.; Taufiq, M.

    2016-01-01

    Objective: To determine the diagnostic accuracy of Diffusion-Weighted Magnetic Resonance Imaging (DWMRI) in the detection of myometrial invasion in endometrial cancer taking histopathology as gold standard. Study Design: Cross-sectional validation study. Place and Duration of Study: Department of Radiology, The Aga Khan University Hospital, Karachi, from January to December 2012. Methodology: DWMRI (b-value = 50,400 and 800 s/mm2) was performed in 85 patients of biopsy-proven endometrial carcinoma before hysterectomy using body and spine coil at 1.5 Tesla. DWI was evaluated for presence of myometrial invasion by tumor with histopathology as gold standard. Sensitivity, specificity, the negative predictive value and positive predictive value and accuracy of DWI were assessed against the gold standard. Results: On DWI, superficial myometrial invasion was found in 42 patients and deep myometrial invasion in 43. On histopathology, superficial myometrial invasion was found in 53 patients and deep myometrial invasion in 32. Hence sensitivity, specificity, positive predictive value, negative predictive value and accuracy for the assessment of myometrial invasion by endometrial tumor on DW images was 90 percentage, 73 percentage, 67 percentage, 92 percentage and 80 percentage, respectively. Diagnostic accuracy of diffusion-weighted magnetic resonance imaging in detection of myometrial invasion in endometrial cancer was 80 percentage. Conclusion: DWI is highly accurate in assessing myometrial invasion and can be used as an adjunct to routine MRI for pre-operative evaluation of myometrial invasion of endometrial cancer. (author)

  5. The diagnostic test accuracy of ultrasound for the detection of lateral epicondylitis: a systematic review and meta-analysis.

    Science.gov (United States)

    Latham, S K; Smith, T O

    2014-05-01

    The purpose of this study was to determine the diagnostic test accuracy of ultrasound for the detection of lateral epicondylitis. An electronic search of databases registering published (MEDLINE, EMBASE, CINAHL, AMED, Cochrane Library, ScienceDirect) and unpublished literature was conducted to January 2013. All diagnostic accuracy studies that compared the accuracy of ultrasound (index test) with a reference standard for lateral epicondylitis were included. The methodological quality of each of the studies was appraised using the QUADAS tool. When appropriate, the pooled sensitivity and specificity analysis was conducted. Ten studies investigating 711 participants and 1077 elbows were included in this review. Ultrasound had variable sensitivity and specificity (sensitivity: 64%-100%; specificity: 36%-100%). The available literature had modest methodological quality, and was limited in terms of sample sizes and blinding between index and reference test results. There is evidence to support the use of ultrasound in the detection of lateral epicondylitis. However, its accuracy appears to be highly dependent on numerous variables, such as operator experience, equipment and stage of pathology. Judgement should be used when considering the benefit of ultrasound for use in clinical practice. Further research assessing variables such a transducer frequency independently is specifically warranted. Level II. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  6. 16-slice MDCT arthrography of the shoulder: accuracy for detection of glenoid labral and rotator cuff tears

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gang Deuk; Kim, Huoung Jun; Kim, Hye Won; Oh, Jung Taek; Juhng, Seon Kwan [Wonkwang University Hospital, Iksan (Korea, Republic of); Lee, Sung Ah [Seoul Medical Center, Seoul (Korea, Republic of)

    2007-04-15

    We wanted to determine the diagnostic accuracy of 16-slice MDCT arthrography (CTA) for glenoid labral and rotator cuff tears of the shoulder. We enrolled forty-five patients who underwent arthroscopy after CTA for pain or instability of the shoulder joint. The CTA images were analyzed for the existence, sites and types of glenoid labral tears and the presence and severity of rotator cuff tears. We determined the sensitivity, specificity and accuracy of CTA for detecting glenoid labral and rotator cuff tears on the basis of the arthroscopy findings. At arthroscopy, there were 33 SLAP lesions (9 type I, 23 type II and 1 type III), 6 Bankart lesions and 31 rotator cuff lesions (21 supraspinatus, 9 infraspinatus and 1 subscapularis). On CTA, the sensitivity, specificity and accuracy for detecting 24 SLAP lesions, excluding the type I lesions, were 83%, 100% and 91%, the total rotator cuff tears were 90%, 100% and 98%, the full thickness supraspinatus tendon tears were 100%, 94% and 96%, and the partial thickness supraspinatus tendon tears were 29%, 100% and 89%, respectively. 16-slice MDCT arthrography has high accuracy for the diagnosis of abnormality of the glenoid labrum or rotator cuff tears and it can be a useful alternative to MRI or US.

  7. A sequential sampling account of response bias and speed-accuracy tradeoffs in a conflict detection task.

    Science.gov (United States)

    Vuckovic, Anita; Kwantes, Peter J; Humphreys, Michael; Neal, Andrew

    2014-03-01

    Signal Detection Theory (SDT; Green & Swets, 1966) is a popular tool for understanding decision making. However, it does not account for the time taken to make a decision, nor why response bias might change over time. Sequential sampling models provide a way of accounting for speed-accuracy trade-offs and response bias shifts. In this study, we test the validity of a sequential sampling model of conflict detection in a simulated air traffic control task by assessing whether two of its key parameters respond to experimental manipulations in a theoretically consistent way. Through experimental instructions, we manipulated participants' response bias and the relative speed or accuracy of their responses. The sequential sampling model was able to replicate the trends in the conflict responses as well as response time across all conditions. Consistent with our predictions, manipulating response bias was associated primarily with changes in the model's Criterion parameter, whereas manipulating speed-accuracy instructions was associated with changes in the Threshold parameter. The success of the model in replicating the human data suggests we can use the parameters of the model to gain an insight into the underlying response bias and speed-accuracy preferences common to dynamic decision-making tasks. © 2013 American Psychological Association

  8. 16-slice MDCT arthrography of the shoulder: accuracy for detection of glenoid labral and rotator cuff tears

    International Nuclear Information System (INIS)

    Kim, Gang Deuk; Kim, Huoung Jun; Kim, Hye Won; Oh, Jung Taek; Juhng, Seon Kwan; Lee, Sung Ah

    2007-01-01

    We wanted to determine the diagnostic accuracy of 16-slice MDCT arthrography (CTA) for glenoid labral and rotator cuff tears of the shoulder. We enrolled forty-five patients who underwent arthroscopy after CTA for pain or instability of the shoulder joint. The CTA images were analyzed for the existence, sites and types of glenoid labral tears and the presence and severity of rotator cuff tears. We determined the sensitivity, specificity and accuracy of CTA for detecting glenoid labral and rotator cuff tears on the basis of the arthroscopy findings. At arthroscopy, there were 33 SLAP lesions (9 type I, 23 type II and 1 type III), 6 Bankart lesions and 31 rotator cuff lesions (21 supraspinatus, 9 infraspinatus and 1 subscapularis). On CTA, the sensitivity, specificity and accuracy for detecting 24 SLAP lesions, excluding the type I lesions, were 83%, 100% and 91%, the total rotator cuff tears were 90%, 100% and 98%, the full thickness supraspinatus tendon tears were 100%, 94% and 96%, and the partial thickness supraspinatus tendon tears were 29%, 100% and 89%, respectively. 16-slice MDCT arthrography has high accuracy for the diagnosis of abnormality of the glenoid labrum or rotator cuff tears and it can be a useful alternative to MRI or US

  9. Accuracy and Coordination of Spatial Frames of Reference during the Exploration of Virtual Maps: Interest for Orientation and Mobility of Blind People?

    Directory of Open Access Journals (Sweden)

    Mathieu Simonnet

    2012-01-01

    Full Text Available Even if their spatial reasoning capabilities remain quite similar to those of sighted people, blind people encounter difficulties in getting distant information from their surroundings. Thus, whole body displacements, tactile map consultations, or auditory solutions are needed to establish physical contacts with their environment. Therefore, the accuracy of nonvisual spatial representations heavily relies upon the efficiency of exploration strategies and the ability to coordinate egocentric and allocentric spatial frames of reference. This study aims to better understand the mechanisms of this coordination without vision by analyzing cartographic exploration strategies and assessing their influence on mental spatial representations. Six blind sailors were immersed within a virtual haptic and auditory maritime environment. They were required to learn the layout of the map. Their movements were recorded and we identified some exploration strategies. Then they had to estimate the directions of six particular seamarks in aligned and misaligned situations. Better accuracy and coordination were obtained when participants used the “central point of reference” strategy. Our discussion relative to the articulation between geometric enduring representations and salient transient perceptions provides implications on map reading techniques and on mobility and orientation programs for blind people.

  10. Coupling Uncertainties with Accuracy Assessment in Object-Based Slum Detections, Case Study: Jakarta, Indonesia

    NARCIS (Netherlands)

    Pratomo, J.; Kuffer, M.; Martinez, Javier; Kohli, D.

    2017-01-01

    Object-Based Image Analysis (OBIA) has been successfully used to map slums. In general, the occurrence of uncertainties in producing geographic data is inevitable. However, most studies concentrated solely on assessing the classification accuracy and neglecting the inherent uncertainties. Our

  11. Diagnostic accuracy of static CT perfusion for the detection of myocardial ischemia

    DEFF Research Database (Denmark)

    Sørgaard, Mathias Holm; Kofoed, Klaus Fuglsang; Linde, Jesper James

    2016-01-01

    : Systematic literature review and meta-analysis of studies examining the diagnostic accuracy of static CTP imaging alone or combined with coronary CT angiography (CTA) in comparison to single photon emission computed tomography (SPECT), magnetic resonance perfusion (MRP), and/or invasive coronary angiography...

  12. Spatial correlation analysis of urban traffic state under a perspective of community detection

    Science.gov (United States)

    Yang, Yanfang; Cao, Jiandong; Qin, Yong; Jia, Limin; Dong, Honghui; Zhang, Aomuhan

    2018-05-01

    Understanding the spatial correlation of urban traffic state is essential for identifying the evolution patterns of urban traffic state. However, the distribution of traffic state always has characteristics of large spatial span and heterogeneity. This paper adapts the concept of community detection to the correlation network of urban traffic state and proposes a new perspective to identify the spatial correlation patterns of traffic state. In the proposed urban traffic network, the nodes represent road segments, and an edge between a pair of nodes is added depending on the result of significance test for the corresponding correlation of traffic state. Further, the process of community detection in the urban traffic network (named GWPA-K-means) is applied to analyze the spatial dependency of traffic state. The proposed method extends the traditional K-means algorithm in two steps: (i) redefines the initial cluster centers by two properties of nodes (the GWPA value and the minimum shortest path length); (ii) utilizes the weight signal propagation process to transfer the topological information of the urban traffic network into a node similarity matrix. Finally, numerical experiments are conducted on a simple network and a real urban road network in Beijing. The results show that GWPA-K-means algorithm is valid in spatial correlation analysis of traffic state. The network science and community structure analysis perform well in describing the spatial heterogeneity of traffic state on a large spatial scale.

  13. Comparison of accuracy of uncorrected and corrected sagittal tomography in detection of mandibular condyle erosions: An exvivo study

    Directory of Open Access Journals (Sweden)

    Asieh Zamani Naser

    2010-01-01

    Full Text Available Background: Radiographic examination of TMJ is indicated when there are clinical signs of pathological conditions, mainly bone changes that may influence the diagnosis and treatment planning. The purpose of this study was to evaluate and to compare the validity and diagnostic accuracy of uncorrected and corrected sagittal tomographic images in the detection of simulated mandibular condyle erosions. Methods : Simulated lesions were created in 10 dry mandibles using a dental round bur. Using uncorrected and corrected sagittal tomography techniques, mandibular condyles were imaged by a Cranex Tome X-ray unit before and after creating the lesions. The uncorrected and corrected tomography images were examined by two independent observers for absence or presence of a lesion. The accuracy for detecting mandibular condyle lesions was expressed as sensitivity, specificity, and validity values. Differences between the two radiographic modalities were tested by Wilcoxon for paired data tests. Inter-observer agreement was determined by Cohen′s Kappa. Results: The sensitivity, specificity and validity were 45%, 85% and 30% in uncorrected sagittal tomographic images, respectively, and 70%, 92.5% and 60% in corrected sagittal tomographic images, respectively. There was a significant statistical difference between the accuracy of uncorrected and corrected sagittal tomography in detection of mandibular condyle erosions (P = 0.016. The inter-observer agreement was slight for uncorrected sagittal tomography and moderate for corrected sagittal tomography. Conclusion: The accuracy of corrected sagittal tomography is significantly higher than that of uncorrected sagittal tomography. Therefore, corrected sagittal tomography seems to be a better modality in detection of mandibular condyle erosions.

  14. Accuracy of Clinical Tests in Detecting Disk Herniation and Nerve Root Compression in Subjects With Lumbar Radicular Symptoms.

    Science.gov (United States)

    Ekedahl, Harald; Jönsson, Bo; Annertz, Mårten; Frobell, Richard B

    2018-04-01

    To investigate the accuracy of 3 commonly used neurodynamic tests (slump test, straight-leg raise [SLR] test, femoral neurodynamic test) and 2 clinical assessments to determine radiculopathy (radiculopathy I, 1 neurologic sign; radiculopathy II, 2 neurologic signs corresponding to 1 specific nerve root) in detecting magnetic resonance imaging (MRI) findings (extrusion, subarticular nerve root compression, and foraminal nerve root compression). Validity study. Secondary care. We included subjects (N=99; mean age, 58y; 54% women) referred for epidural steroid injection because of lumbar radicular symptoms who had positive clinical and MRI findings. Positive clinical findings included the slump test (n=67), SLR test (n=50), femoral neurodynamic test (n=7), radiculopathy I (n=70), and radiculopathy II (n=33). Positive MRI findings included extrusion (n=27), subarticular nerve compression (n=14), and foraminal nerve compression (n=25). Not applicable. Accuracy of clinical tests in detecting MRI findings was evaluated using sensitivity, specificity, and receiver operating characteristics analysis with area under the curve (AUC). The slump test had the highest sensitivity in detecting extrusion (.78) and subarticular nerve compression (1.00), but the respective specificity was low (.36 and .38). Radiculopathy I was most sensitive in detecting foraminal nerve compression (.80) but with low specificity (.34). Only 1 assessment had a concurrent high sensitivity and specificity (ie, radiculopathy II) in detecting subarticular nerve compression (.71 and .73, respectively). The AUC for all tests in detecting extrusion, subarticular nerve compression, and foraminal nerve compression showed ranges of .48 to .60, .63 to .82, and .33 to .57, respectively. In general, the investigated neurodynamic tests or assessments for radiculopathy lacked diagnostic accuracy. The slump test was the most sensitive test, while radiculopathy II was the most specific test. Most interestingly, no

  15. Development and validation of an automated and marker-free CT-based spatial analysis method (CTSA) for assessment of femoral hip implant migration: In vitro accuracy and precision comparable to that of radiostereometric analysis (RSA).

    Science.gov (United States)

    Scheerlinck, Thierry; Polfliet, Mathias; Deklerck, Rudi; Van Gompel, Gert; Buls, Nico; Vandemeulebroucke, Jef

    2016-01-01

    We developed a marker-free automated CT-based spatial analysis (CTSA) method to detect stem-bone migration in consecutive CT datasets and assessed the accuracy and precision in vitro. Our aim was to demonstrate that in vitro accuracy and precision of CTSA is comparable to that of radiostereometric analysis (RSA). Stem and bone were segmented in 2 CT datasets and both were registered pairwise. The resulting rigid transformations were compared and transferred to an anatomically sound coordinate system, taking the stem as reference. This resulted in 3 translation parameters and 3 rotation parameters describing the relative amount of stem-bone displacement, and it allowed calculation of the point of maximal stem migration. Accuracy was evaluated in 39 comparisons by imposing known stem migration on a stem-bone model. Precision was estimated in 20 comparisons based on a zero-migration model, and in 5 patients without stem loosening. Limits of the 95% tolerance intervals (TIs) for accuracy did not exceed 0.28 mm for translations and 0.20° for rotations (largest standard deviation of the signed error (SD(SE)): 0.081 mm and 0.057°). In vitro, limits of the 95% TI for precision in a clinically relevant setting (8 comparisons) were below 0.09 mm and 0.14° (largest SD(SE): 0.012 mm and 0.020°). In patients, the precision was lower, but acceptable, and dependent on CT scan resolution. CTSA allows detection of stem-bone migration with an accuracy and precision comparable to that of RSA. It could be valuable for evaluation of subtle stem loosening in clinical practice.

  16. Detection of User Independent Single Trial ERPs in Brain Computer Interfaces: An Adaptive Spatial Filtering Approach

    DEFF Research Database (Denmark)

    Leza, Cristina; Puthusserypady, Sadasivan

    2017-01-01

    Brain Computer Interfaces (BCIs) use brain signals to communicate with the external world. The main challenges to address are speed, accuracy and adaptability. Here, a novel algorithm for P300 based BCI spelling system is presented, specifically suited for single-trial detection of Event...

  17. Second International Diagnostic Accuracy Study for the Serological Detection of West Nile Virus Infection

    OpenAIRE

    Sanchini, Andrea; Donoso-Mantke, Oliver; Papa, Anna; Sambri, Vittorio; Teichmann, Anette; Niedrig, Matthias

    2013-01-01

    Background: In recent decades, sporadic cases and outbreaks in humans of West Nile virus (WNV) infection have increased. Serological diagnosis of WNV infection can be performed by enzyme-linked immunosorbent assay (ELISA), immunofluorescence assay (IFA) neutralization test (NT) and by hemagglutination-inhibition assay. The aim of this study is to collect updated information regarding the performance accuracy of WNV serological diagnostics. Methodology/Principal findings: In 2011, the E...

  18. Evaluation of accuracy of intra operative imprint cytology for detection of breast lesions

    International Nuclear Information System (INIS)

    Mahmood, Z.; Shahbaz, A.; Qureshi, A.; Aziz, N.; Niazi, S.; Qureshi, S.; Bukhari, M.H.

    2010-01-01

    Objective: To determine the accuracy of imprint cytology as an intraoperative diagnostic procedure for breast lesions with histopathological correlation. Materials and Methods: This was a descriptive study on 40 cases of breast lesions comprising of inflammatory, benign and malignant lesions including their margins etc. It was conducted at King Edward Medical University, Lahore in collaboration with all Surgical Departments of Mayo Hospital. Relevant clinical data was recorded in a proforma. Both touch and scrape imprints were prepared from all the lesions and stained with May-Grunwaled Giemsa and Haematoxylin and Eosin stains. The imprints were subsequently compared with histopathology sections. Results: When we used atypical cases as negative both touch and scrape imprints gave sensitivity, specificity, positive predictive value, negative predictive value and accuracy at 100%. However when we used cases with atypia as positive, sensitivity and negative predictive value were 100% with both touch and scrape imprints. Specificity, positive predictive value and accuracy were 71%, 86%, 85.5% respectively with touch imprints and 78%, 89%, 89% respectively with scrape imprints. No diagnostic difference was noted between the results of both stains. All the imprints were well correlated with histopathological diagnosis. Conclusion: Imprint cytology is an accurate and simple intraoperative method for diagnosing breast lesions. It can provide the surgeons with information regarding immediate clinical and surgical interventions. (author)

  19. Accuracy of Estimating Highly Eccentric Binary Black Hole Parameters with Gravitational-wave Detections

    Science.gov (United States)

    Gondán, László; Kocsis, Bence; Raffai, Péter; Frei, Zsolt

    2018-03-01

    Mergers of stellar-mass black holes on highly eccentric orbits are among the targets for ground-based gravitational-wave detectors, including LIGO, VIRGO, and KAGRA. These sources may commonly form through gravitational-wave emission in high-velocity dispersion systems or through the secular Kozai–Lidov mechanism in triple systems. Gravitational waves carry information about the binaries’ orbital parameters and source location. Using the Fisher matrix technique, we determine the measurement accuracy with which the LIGO–VIRGO–KAGRA network could measure the source parameters of eccentric binaries using a matched filtering search of the repeated burst and eccentric inspiral phases of the waveform. We account for general relativistic precession and the evolution of the orbital eccentricity and frequency during the inspiral. We find that the signal-to-noise ratio and the parameter measurement accuracy may be significantly higher for eccentric sources than for circular sources. This increase is sensitive to the initial pericenter distance, the initial eccentricity, and the component masses. For instance, compared to a 30 {M}ȯ –30 {M}ȯ non-spinning circular binary, the chirp mass and sky-localization accuracy can improve by a factor of ∼129 (38) and ∼2 (11) for an initially highly eccentric binary assuming an initial pericenter distance of 20 M tot (10 M tot).

  20. Is diagnostic accuracy for detecting pulmonary nodules in chest CT reduced after a long day of reading?

    Science.gov (United States)

    Krupinski, Elizabeth A.; Berbaum, Kevin S.; Caldwell, Robert; Schartz, Kevin M.

    2012-02-01

    Radiologists are reading more cases with more images, especially in CT and MRI and thus working longer hours than ever before. There have been concerns raised regarding fatigue and whether it impacts diagnostic accuracy. This study measured the impact of reader visual fatigue by assessing symptoms, visual strain via dark focus of accommodation, and diagnostic accuracy. Twenty radiologists and 20 radiology residents were given two diagnostic performance tests searching CT chest sequences for a solitary pulmonary nodule before (rested) and after (tired) a day of clinical reading. 10 cases used free search and navigation, and the other 100 cases used preset scrolling speed and duration. Subjects filled out the Swedish Occupational Fatigue Inventory (SOFI) and the oculomotor strain subscale of the Simulator Sickness Questionnaire (SSQ) before each session. Accuracy was measured using ROC techniques. Using Swensson's technique yields an ROC area = 0.86 rested vs. 0.83 tired, p (one-tailed) = 0.09. Using Swensson's LROC technique yields an area = 0.73 rested vs. 0.66 tired, p (one-tailed) = 0.09. Using Swensson's Loc Accuracy technique yields an area = 0.77 rested vs. 0.72 tired, p (one-tailed) = 0.13). Subjective measures of fatigue increased significantly from early to late reading. To date, the results support our findings with static images and detection of bone fractures. Radiologists at the end of a long work day experience greater levels of measurable visual fatigue or strain, contributing to a decrease in diagnostic accuracy. The decrease in accuracy was not as great however as with static images.

  1. Spatial variability in sensitivity of reference crop ET to accuracy of climate data in the Texas High Plains

    Science.gov (United States)

    A detailed sensitivity analysis was conducted to determine the relative effects of measurement errors in climate data input parameters on the accuracy of calculated reference crop evapotranspiration (ET) using the ASCE-EWRI Standardized Reference ET Equation. Data for the period of 1995 to 2008, fro...

  2. Diagnostic accuracy of tests to detect hepatitis B surface antigen: a systematic review of the literature and meta-analysis

    Directory of Open Access Journals (Sweden)

    Ali Amini

    2017-11-01

    Full Text Available Abstract Background Chronic Hepatitis B Virus (HBV infection is characterised by the persistence of hepatitis B surface antigen (HBsAg. Expanding HBV diagnosis and treatment programmes into low resource settings will require high quality but inexpensive rapid diagnostic tests (RDTs in addition to laboratory-based enzyme immunoassays (EIAs to detect HBsAg. The purpose of this review is to assess the clinical accuracy of available diagnostic tests to detect HBsAg to inform recommendations on testing strategies in 2017 WHO hepatitis testing guidelines. Methods The systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA guidelines using 9 databases. Two reviewers independently extracted data according to a pre-specified plan and evaluated study quality. Meta-analysis was performed. HBsAg diagnostic accuracy of rapid diagnostic tests (RDTs was compared to enzyme immunoassay (EIA and nucleic-acid test (NAT reference standards. Subanalyses were performed to determine accuracy among brands, HIV-status and specimen type. Results Of the 40 studies that met the inclusion criteria, 33 compared RDTs and/or EIAs against EIAs and 7 against NATs as reference standards. Thirty studies assessed diagnostic accuracy of 33 brands of RDTs in 23,716 individuals from 23 countries using EIA as the reference standard. The pooled sensitivity and specificity were 90.0% (95% CI: 89.1, 90.8 and 99.5% (95% CI: 99.4, 99.5 respectively, but accuracy varied widely among brands. Accuracy did not differ significantly whether serum, plasma, venous or capillary whole blood was used. Pooled sensitivity of RDTs in 5 studies of HIV-positive persons was lower at 72.3% (95% CI: 67.9, 76.4 compared to that in HIV-negative persons, but specificity remained high. Five studies evaluated 8 EIAs against a chemiluminescence immunoassay reference standard with a pooled sensitivity and specificity of 88.9% (95% CI: 87.0, 90.6 and

  3. Web-based GIS for spatial pattern detection: application to malaria incidence in Vietnam.

    Science.gov (United States)

    Bui, Thanh Quang; Pham, Hai Minh

    2016-01-01

    There is a great concern on how to build up an interoperable health information system of public health and health information technology within the development of public information and health surveillance programme. Technically, some major issues remain regarding to health data visualization, spatial processing of health data, health information dissemination, data sharing and the access of local communities to health information. In combination with GIS, we propose a technical framework for web-based health data visualization and spatial analysis. Data was collected from open map-servers and geocoded by open data kit package and data geocoding tools. The Web-based system is designed based on Open-source frameworks and libraries. The system provides Web-based analyst tool for pattern detection through three spatial tests: Nearest neighbour, K function, and Spatial Autocorrelation. The result is a web-based GIS, through which end users can detect disease patterns via selecting area, spatial test parameters and contribute to managers and decision makers. The end users can be health practitioners, educators, local communities, health sector authorities and decision makers. This web-based system allows for the improvement of health related services to public sector users as well as citizens in a secure manner. The combination of spatial statistics and web-based GIS can be a solution that helps empower health practitioners in direct and specific intersectional actions, thus provide for better analysis, control and decision-making.

  4. Diagnostic Accuracy of the Volume Rendering Images of Multi-Detector CT for the Detection of Lumbar Transverse Process Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yun Hak; Chun, Tong Jin [Dept. of Radiology, Eulji University Hospital, Daejeon (Korea, Republic of)

    2012-01-15

    To compare the accuracy of three-dimensional computed tomographic (3D CT) volume rendering techniques with axial images of multi-detector row computed tomography to identify lumbar transverse process (LTP) fractures in trauma patients. We retrospectively evaluated 42 patients with back pain as a result of blunt trauma between January and June of 2010. Two radiologists examined the 3D CT volume rendering images independently. The confirmation of a LTP fracture was based on the consensus of the axial images by the two radiologists. The results of 3D CT volume rendering images were compared with the axial images and the diagnostic powers (sensitivity, specificity, and accuracy) were calculated. Seven of the 42 patients had twenty five lumbar transverse process fractures. The diagnostic power of the 3D CT volume rendering technique is as accurate as axial images. Reader 1, sensitivity 96%, specificity 100%, accuracy 99.9%; and Reader 2 sensitivity 100%, specificity 99.8%, accuracy 99.8%. The accordance of the two radiologists was 99.8%. 3D CT volume rendering images can alternate axial images to detect lumbar transverse process fractures with good image quality.

  5. Accuracy of Administrative Billing Codes to Detect Urinary Tract Infection Hospitalizations

    Science.gov (United States)

    Hall, Matthew; Auger, Katherine A.; Hain, Paul D.; Jerardi, Karen E.; Myers, Angela L.; Rahman, Suraiya S.; Williams, Derek J.; Shah, Samir S.

    2011-01-01

    BACKGROUND: Hospital billing data are frequently used for quality measures and research, but the accuracy of the use of discharge codes to identify urinary tract infections (UTIs) is unknown. OBJECTIVE: To determine the accuracy of International Classification of Diseases, 9th revision (ICD-9) discharge codes to identify children hospitalized with UTIs. METHODS: This multicenter study conducted in 5 children's hospitals included children aged 3 days to 18 years who had been admitted to the hospital, undergone a urinalysis or urine culture, and discharged from the hospital. Data were obtained from the pediatric health information system database and medical record review. With the use of 2 gold-standard methods, the positive predictive value (PPV) was calculated for individual and combined UTI codes and for common UTI identification strategies. PPV was measured for all groupings for which the UTI code was the principal discharge diagnosis. RESULTS: There were 833 patients in the study. The PPV was 50.3% with the use of the gold standard of laboratory-confirmed UTIs but increased to 85% with provider confirmation. Restriction of the study cohort to patients with a principle diagnosis of UTI improved the PPV for laboratory-confirmed UTI (61.2%) and provider-confirmed UTI (93.2%), as well as the ability to benchmark performance. Other common identification strategies did not markedly affect the PPV. CONCLUSIONS: ICD-9 codes can be used to identify patients with UTIs but are most accurate when UTI is the principal discharge diagnosis. The identification strategies reported in this study can be used to improve the accuracy and applicability of benchmarking measures. PMID:21768320

  6. Evaluating the influence of spatial resolution of Landsat predictors on the accuracy of biomass models for large-area estimation across the eastern USA

    Science.gov (United States)

    Deo, Ram K.; Domke, Grant M.; Russell, Matthew B.; Woodall, Christopher W.; Andersen, Hans-Erik

    2018-05-01

    Aboveground biomass (AGB) estimates for regional-scale forest planning have become cost-effective with the free access to satellite data from sensors such as Landsat and MODIS. However, the accuracy of AGB predictions based on passive optical data depends on spatial resolution and spatial extent of target area as fine resolution (small pixels) data are associated with smaller coverage and longer repeat cycles compared to coarse resolution data. This study evaluated various spatial resolutions of Landsat-derived predictors on the accuracy of regional AGB models at three different sites in the eastern USA: Maine, Pennsylvania-New Jersey, and South Carolina. We combined national forest inventory data with Landsat-derived predictors at spatial resolutions ranging from 30–1000 m to understand the optimal spatial resolution of optical data for large-area (regional) AGB estimation. Ten generic models were developed using the data collected in 2014, 2015 and 2016, and the predictions were evaluated (i) at the county-level against the estimates of the USFS Forest Inventory and Analysis Program which relied on EVALIDator tool and national forest inventory data from the 2009–2013 cycle and (ii) within a large number of strips (~1 km wide) predicted via LiDAR metrics at 30 m spatial resolution. The county-level estimates by the EVALIDator and Landsat models were highly related (R 2 > 0.66), although the R 2 varied significantly across sites and resolution of predictors. The mean and standard deviation of county-level estimates followed increasing and decreasing trends, respectively, with models of coarser resolution. The Landsat-based total AGB estimates were larger than the LiDAR-based total estimates within the strips, however the mean of AGB predictions by LiDAR were mostly within one-standard deviations of the mean predictions obtained from the Landsat-based model at any of the resolutions. We conclude that satellite data at resolutions up to 1000 m provide

  7. A Comparison of Data Sets Varying in Spatial Accuracy Used to Predict the Occurrence of Wildlife-Vehicle Collisions

    Science.gov (United States)

    Gunson, Kari E.; Clevenger, Anthony P.; Ford, Adam T.; Bissonette, John A.; Hardy, Amanda

    2009-08-01

    Wildlife-vehicle collisions (WVCs) pose a significant safety and conservation concern in areas where high-traffic roads are situated adjacent to wildlife habitat. Improving transportation safety, accurately planning highway mitigation, and identifying key habitat linkage areas may all depend on the quality of WVC data collection. Two common approaches to describe the location of WVCs are spatially accurate data derived from global positioning systems (GPS) or vehicle odometer measurements and less accurate road-marker data derived from reference points (e.g., mile-markers or landmarks) along the roadside. In addition, there are two common variable types used to predict WVC locations: (1) field-derived, site-specific measurements and (2) geographic information system (GIS)-derived information. It is unclear whether these different approaches produce similar results when attempting to identify and explain the location of WVCs. Our first objective was to determine and compare the spatial error found in road-marker data (in our case the closest mile-marker) and landmark-referenced data. Our second objective was to evaluate the performance of models explaining high- and low-probability WVC locations, using congruent, spatially accurate (GIS-derived explanatory variables. Our WVC data sets were comprised of ungulate collisions and were located along five major roads in the central Canadian Rocky Mountains. We found that spatial error (mean ± SD) was higher for WVC data referenced to nearby landmarks (516 ± 808 m) than for data referenced to the closest mile-marker data (401 ± 219 m). The top-performing model using the spatially accurate WVC locations contained all explanatory variable types, whereas GIS-derived variables were only influential in the best road-marker model and the spatially accurate reduced model. Our study showed that spatial error and sample size, using road-marker data for ungulate species, are important to consider for model output interpretation

  8. Tools for Multimode Quantum Information: Modulation, Detection, and Spatial Quantum Correlations

    DEFF Research Database (Denmark)

    Lassen, Mikael Østergaard; Delaubert, Vincent; Janousek, Jirí

    2007-01-01

    We present here all the tools required for continuous variable parallel quantum information protocols based on spatial multi-mode quantum correlations and entanglement. We describe techniques for encoding and detecting this quantum information with high efficiency in the individual modes. We use ...

  9. Spatially valid proprioceptive cues improve the detection of a visual stimulus

    DEFF Research Database (Denmark)

    Jackson, Carl P T; Miall, R Chris; Balslev, Daniela

    2010-01-01

    , which has been demonstrated for other modality pairings. The aim of this study was to test whether proprioceptive signals can spatially cue a visual target to improve its detection. Participants were instructed to use a planar manipulandum in a forward reaching action and determine during this movement...

  10. Spatial Modeling of Industrial Windfall on Soils to Detect Woody Species with Potential for Bioremediation

    Science.gov (United States)

    S. Salazar; M. Mendoza; A. M. Tejeda

    2006-01-01

    A spatial model is presented to explain the concentration of heavy metals (Fe, Cu, Zn, Ni, Cr, Co and Pb), in the soils around the industrial complex near the Port of Veracruz, Mexico. Unexpected low concentration sites where then tested to detect woody plant species that may have the capability to hiperacumulate these contaminants, hence having a potential for...

  11. The spatial resolution of the porcine multifocal electroretinogram for detection of laser-induced retinal lesions

    DEFF Research Database (Denmark)

    Kyhn, Maria Voss; Kiilgaard, Jens Folke; Scherfig, Erik

    2008-01-01

    This study aimed to investigate the spatial resolution of a porcine multifocal electroretinogram (mfERG) protocol by testing its ability to detect laser-induced retinal lesions. Furthermore, we wanted to describe time-dependent changes in implicit time and amplitude of the different mfERG peaks...

  12. Moving target detection based on temporal-spatial information fusion for infrared image sequences

    Science.gov (United States)

    Toing, Wu-qin; Xiong, Jin-yu; Zeng, An-jun; Wu, Xiao-ping; Xu, Hao-peng

    2009-07-01

    Moving target detection and localization is one of the most fundamental tasks in visual surveillance. In this paper, through analyzing the advantages and disadvantages of the traditional approaches about moving target detection, a novel approach based on temporal-spatial information fusion is proposed for moving target detection. The proposed method combines the spatial feature in single frame and the temporal properties within multiple frames of an image sequence of moving target. First, the method uses the spatial image segmentation for target separation from background and uses the local temporal variance for extracting targets and wiping off the trail artifact. Second, the logical "and" operator is used to fuse the temporal and spatial information. In the end, to the fusion image sequence, the morphological filtering and blob analysis are used to acquire exact moving target. The algorithm not only requires minimal computation and memory but also quickly adapts to the change of background and environment. Comparing with other methods, such as the KDE, the Mixture of K Gaussians, etc., the simulation results show the proposed method has better validity and higher adaptive for moving target detection, especially in infrared image sequences with complex illumination change, noise change, and so on.

  13. Accuracy of phenotypic methicillin susceptibility methods in the detection of Staphylococcus aureus isolates carrying different SCCmec types

    Directory of Open Access Journals (Sweden)

    Pricilla DM de Matos

    2010-11-01

    Full Text Available A total of 138 isolates, 118 methicillin-resistant Staphylococcus aureus (MRSA isolates (staphylococcal cassette chromosome type II, 20 isolates, type III, 39 isolates and type IV, 59 isolates and 20 methicillin-sensitive S. aureus isolates were evaluated by phenotypic methods: cefoxitin and oxacillin disk diffusion (DD, agar dilution (AD, latex agglutination (LA, oxacillin agar screening (OAS and chromogenic agar detection. All methods showed 100% specificity, but only the DD tests presented 100% sensitivity. The sensitivity of the other tests ranged from 82.2% (OAS-98.3% (AD. The LA test showed the second lowest sensitivity (86.4%. The DD test showed high accuracy in the detection of MRSA isolates, but there was low precision in the detection of type IV isolates by the other tests, indicating that the genotypic characteristics of the isolates should be considered.

  14. Accuracy of phenotypic methicillin susceptibility methods in the detection of Staphylococcus aureus isolates carrying different SCCmec types.

    Science.gov (United States)

    Matos, Pricilla D M de; Schuenck, Ricardo P; Cavalcante, Fernanda S; Caboclo, Roberta M F; Santos, Kátia Regina N dos

    2010-11-01

    A total of 138 isolates, 118 methicillin-resistant Staphylococcus aureus (MRSA) isolates (staphylococcal cassette chromosome type II, 20 isolates, type III, 39 isolates and type IV, 59 isolates) and 20 methicillin-sensitive S. aureus isolates were evaluated by phenotypic methods: cefoxitin and oxacillin disk diffusion (DD), agar dilution (AD), latex agglutination (LA), oxacillin agar screening (OAS) and chromogenic agar detection. All methods showed 100% specificity, but only the DD tests presented 100% sensitivity. The sensitivity of the other tests ranged from 82.2% (OAS)-98.3% (AD). The LA test showed the second lowest sensitivity (86.4%). The DD test showed high accuracy in the detection of MRSA isolates, but there was low precision in the detection of type IV isolates by the other tests, indicating that the genotypic characteristics of the isolates should be considered.

  15. Diagnostic accuracy of ultrasound, computed tomography, and endoscopic retrograde choleangiopancreatography in the detection of obstructive jaundice

    International Nuclear Information System (INIS)

    Pasanen, P.A.; Partainen, K.; Pikkarainen, P.; Alhava, E.; Pirinen, A.; Janatuinen, E.

    1991-01-01

    The purpose of this prospective study was to investigate the diagnostic accuracy of ultrasound (US), computed tomography (CT), and endoscopic retrograde cholangiopancreatography (ERCP) in the distinction between extrahepatic and intrahepatic causes of jaundice. The limit for the inclusion to the study was defined as a serum bilirubin concentration ≥40μmol/l. Altogether 187 jaundiced patients were studied. The sensitivities of US, CT and ERCP were 63%, 77%, and 87%, respectively. The differences between all these methods were statistically significant. The specificities and positive predictive values were high, reaching 96-99%, but the negative predictive values were low, ranging between 38% and 60%. Choledochal stone disease constituted the main etiology of false-negative studies in all investigations. Imaging procedures have a prominent role in the diagnostic study of the jaundiced patient, but it is obvious that their diagnostic accuracy may vary between institutions because of the variance in local experience and expertise and because of the differences in diseases causing jaundice. 37 refs., 5 tabs

  16. [Accuracy of computer aided measurement for detecting dental proximal caries lesions in images of cone-beam computed tomography].

    Science.gov (United States)

    Zhang, Z L; Li, J P; Li, G; Ma, X C

    2017-02-09

    Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the

  17. Initial accuracy assessment of the modified S-LANSS for the detection of neuropathic orofacial pain conditions.

    Science.gov (United States)

    Herrero Babiloni, Alberto; Nixdorf, Donald R; Law, Alan S; Moana-Filho, Estephan J; Shueb, Sarah S; Nguyen, Ruby H; Durham, Justin

    2017-01-01

    To evaluate the accuracy of a questionnaire modified for the identification of intraoral pain with neuropathic characteristics in a clinical orofacial pain sample population. 136 participants with at least one of four orofacial pain diagnoses (temporomandibular disorders [TMD, n = 41], acute dental pain [ADP, n = 41], trigeminal neuralgia [TN, n = 19], persistent dentoalveolar pain disorder [PDAP, n = 14]) and a group of pain-free controls (n = 21) completed the modified S-LANSS, a previously adapted version of the original questionnaire devised to detected patients suffering from intraoral pain with neuropathic characteristics. Psychometric properties (sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV]) were calculated in two analyses with two different thresholds: (1) Detection of pain with neuropathic characteristics: PDAP + TN were considered positive, and TMD + ADP + controls were considered negative per gold standard (expert opinion). (2) Detection of PDAP: PDAP was considered positive and TMD + ADP were considered negative per gold standard. For both analyses, target values for adequate sensitivity and specificity were defined as ≥ 80%. For detection of orofacial pain with neuropathic characteristics (PDAP + TN), the modified S-LANSS presented with the most optimistic threshold sensitivity of 52% (95% confidence interval [CI], 34-69), specificity of 70% (95% CI, 60-79), PPV of 35% (95% CI, 22-51), and NPV of 82% (95% CI, 72-89). For detection of PDAP only, with the most optimistic threshold sensitivity was 64% (95% CI, 35-87), specificity 63% (95% CI, 52-74), PPV 23% (95% CI, 11-39) and NPV 91% (95% CI, 81-97). Based on a priori defined criteria, the modified S-LANSS did not show adequate accuracy to detect intraoral pain with neuropathic characteristics in a clinical orofacial pain sample.

  18. The Accuracy of Plain Radiography in Detection of Traumatic Intrathoracic Injuries

    Directory of Open Access Journals (Sweden)

    Maryam Abedi Khorasgani

    2016-08-01

    Full Text Available Introduction: Rapid diagnosis of traumatic intrathoracic injuries leads to improvement in patient management. This study was designed to evaluate the diagnostic value of chest radiography (CXR in comparison to chest computed tomography (CT scan in diagnosis of traumatic intrathoracic injuries. Methods: Participants of this prospective diagnostic accuracy study included multiple trauma patients over 15 years old with stable vital admitted to emergency department (ED during one year. The correlation of CXR and CT scan findings in diagnosis of traumatic intrathoracic injuries was evaluated using SPSS 20. Screening characteristics of CXR were calculated with 95% CI. Results: 353 patients with the mean age of 35.2 ± 15.8 were evaluated (78.8% male. Age 16-30 years with 121 (34.2%, motorcycle riders with 104 (29.5% cases and ISS < 12 with 185 (52.4% had the highest frequency among patients. Generally, screening performance characteristics of chest in diagnosis of chest traumatic injuries were as follows: sensitivity 50.3 (95% CI: 44.8 – 55.5, specificity 98.9 (95% CI: 99.5 – 99.8, PPV 97.8 (95% CI: 91.5 – 99.6, NPV 66.4 (95% CI: 60.2 – 72.03, PLR 44.5 (95% CI: 11.3 175.3, and NLR 0.5 (95% CI: 0.4 – 0.6. Accuracy of CXR in diagnosis of traumatic intrathoracic injuries was 74.5 (95% CI: 69.6 – 78.9 and its area under the ROC curve was 74.6 (95% CI: 69.3 – 79.8. Conclusion: The screening performance characteristics of CXR in diagnosis of traumatic intrathoracic injuries were higher than 90% in all pathologies except pneumothorax (50.3%. It seems that this matter has a great impact on the general screening characteristics of the test (74.3% accuracy and 50.3%sensitivity. It seems that, plain CXR should be used as an initial screening tool more carefully.

  19. Zero-crossing detection algorithm for arrays of optical spatial filtering velocimetry sensors

    DEFF Research Database (Denmark)

    Jakobsen, Michael Linde; Pedersen, Finn; Hanson, Steen Grüner

    2008-01-01

    This paper presents a zero-crossing detection algorithm for arrays of compact low-cost optical sensors based on spatial filtering for measuring fluctuations in angular velocity of rotating solid structures. The algorithm is applicable for signals with moderate signal-to-noise ratios, and delivers...... repeating the same measurement error for each revolution of the target, and to gain high performance measurement of angular velocity. The traditional zero-crossing detection is extended by 1) inserting an appropriate band-pass filter before the zero-crossing detection, 2) measuring time periods between zero...

  20. Accuracy of automated software-guided detection of significant coronary artery stenosis by CT angiography: comparison with invasive catheterisation

    International Nuclear Information System (INIS)

    Anders, Katharina; Uder, Michael; Achenbach, Stephan; Petit, Isabel; Daniel, Werner G.; Pflederer, Tobias

    2013-01-01

    True automated detection of coronary artery stenoses might be useful whenever expert evaluation is not available, or as a ''second reader'' to enhance diagnostic confidence. We evaluated the accuracy of a PC-based stenosis detection tool alone and combined with expert interpretation. One hundred coronary CT angiography datasets were evaluated with the automated software alone, by manual interpretation (axial images, multiplanar reformations and maximum intensity projections in free double-oblique planes), and by expert interpretation aware of the automated findings. Stenoses ≥ 50 % were noted per-vessel and per-patient, and compared with invasive angiography. Automated post-processing was successful in 90 % of patients (88 % of vessels). When excluding uninterpretable datasets, per-patient sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89 %, 79 %, 74 % and 92 % (per-vessel: 82 %, 85 %, 48 % and 96 %). All 100 datasets were evaluable by expert interpretation. Per-patient sensitivity, specificity, PPV and NPV were 95 %, 95 %, 93 % and 97 % (per-vessel: 89 %,98 %, 88 % and 98 %). Knowing the results of automated interpretation did not improve the performance of expert readers. Automated off-line post-processing of coronary CT angiography shows adequate sensitivity, but relatively low specificity in coronary stenosis detection. It does not increase accuracy of expert interpretation. Failure of post-processing in 10 % of all patients necessitates additional manual image work-up. (orig.)

  1. Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT. Editor`s note

    Energy Technology Data Exchange (ETDEWEB)

    Coakley, F.V. [Abdominal Imaging Section, Department of Radiology, University of California, San Francisco, CA (United States); Cohen, M.D. [Department of Radiology, Riley Hospital for Children, Indianapolis, IN (United States); Waters, D.J. [Department of Veterinary Clinical Sciences, Purdue University, West Lafayette, IN (United States); Davis, M.M. [Department of Pathology, Riley Hospital for Children, Indianapolis, IN (United States); Karmazyn, B. [Department of Radiology, Riley Hospital for Children, Indianapolis, IN (United States); Gonin, R. [Division of Biostatistics, Department of Medicine, Riley Hospital for Children, Indianapolis, IN (United States); Hanna, M.P. [Division of Biostatistics, Department of Medicine, Riley Hospital for Children, Indianapolis, IN (United States)

    1997-07-01

    Background. CT of the chest for suspected pulmonary metastases in adults is generally performed using a breath-hold technique. The results may not be applicable to young children in whom breath-holding may be impossible. Objective. Determine the effect of breathing on the accuracy of pulmonary metastasis detection by spiral CT (SCT). Materials and methods. Prior to euthanasia four anesthetized dogs with metastatic osteosarcoma underwent SCT with a collimation of 5 mm and a pitch of 2, during both induced breath-hold and normal quiet breathing. Images were reconstructed as contiguous 5-mm slices. Macroscopically evident metastases were noted at postmortem. Hard-copy SCT images were reviewed by ten radiologists, each of whom circled all suspected metastases. SCT images were compared with postmortem results to determine true and false positives. Results. The pathologist identified 132 macroscopically evident pulmonary metastases. For metastasis detection, there was no significant difference between breath-hold SCT and breathing SCT. Conclusion. In our animal model, SCT can be performed during normal resting breathing without significant loss of accuracy in the detection of pulmonary metastases. (orig.). With 3 tabs.

  2. Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT. Editor's note

    International Nuclear Information System (INIS)

    Coakley, F.V.; Cohen, M.D.; Waters, D.J.; Davis, M.M.; Karmazyn, B.; Gonin, R.; Hanna, M.P.

    1997-01-01

    Background. CT of the chest for suspected pulmonary metastases in adults is generally performed using a breath-hold technique. The results may not be applicable to young children in whom breath-holding may be impossible. Objective. Determine the effect of breathing on the accuracy of pulmonary metastasis detection by spiral CT (SCT). Materials and methods. Prior to euthanasia four anesthetized dogs with metastatic osteosarcoma underwent SCT with a collimation of 5 mm and a pitch of 2, during both induced breath-hold and normal quiet breathing. Images were reconstructed as contiguous 5-mm slices. Macroscopically evident metastases were noted at postmortem. Hard-copy SCT images were reviewed by ten radiologists, each of whom circled all suspected metastases. SCT images were compared with postmortem results to determine true and false positives. Results. The pathologist identified 132 macroscopically evident pulmonary metastases. For metastasis detection, there was no significant difference between breath-hold SCT and breathing SCT. Conclusion. In our animal model, SCT can be performed during normal resting breathing without significant loss of accuracy in the detection of pulmonary metastases. (orig.). With 3 tabs

  3. Diagnostic accuracy of 18F-FDG PET/CT for detection of suspected recurrence in patients with oesophageal carcinoma

    International Nuclear Information System (INIS)

    Sharma, Punit; Jain, Sachin; Karunanithi, Sellam; Malhotra, Arun; Bal, Chandrasekhar; Kumar, Rakesh; Pal, Sujoy; Julka, Pramod Kumar; Thulkar, Sanjay

    2014-01-01

    To evaluate the role of 18 F-FDG PET/CT in the detection of recurrence in patients with oesophageal carcinoma, suspected clinically or following conventional investigations. This was a retrospective study. Data from 180 patients (age 56.3 ± 10.4 years; 126 men, 54 women) with histopathologically proven oesophageal carcinoma (squamous cell 115, adenocarcinoma 59, neuroendocrine carcinoma 4, small cell 1, poorly differentiated 1) who had undergone 227 18 F-FDG PET/CT studies for suspected recurrence were analysed. Recurrence was suspected clinically or following conventional investigations. PET/CT images were revaluated by two nuclear medicine physicians in consensus. Findings were grouped into local, nodal and distant recurrence. Results were compared to those from contrast-enhanced (CE) CT when available (109 patients). Clinical/imaging follow-up (minimum 6 months) with histopathology (when available) was taken as the reference standard. Of the 227 18 F-FDG PET/CT studies,166 were positive and 61 were negative for recurrent disease. PET/CT showed local recurrence in 134, nodal recurrence in 115 and distant recurrence in 47, with more than one site of recurrence in 34. The PET/CT findings were true-positive in 153 studies, true-negative in 54, false-positive in 13 and false-negative in 7. The sensitivity of 18 F-FDG PET/CT was 96 %, the specificity was 81 %, the positive and negative predictive values were 92 % and 89 %, respectively, and the accuracy was 91 %. PET/CT showed similar accuracy in patients with squamous cell carcinoma and in those with adenocarcinoma (P = 0.181). 18 F-FDG PET/CT was more specific than CECT (67 % vs. 21 %; P 18 F-FDG PET/CT shows high accuracy in the detection of suspected recurrence in patients with oesophageal carcinoma. It is more specific than and is superior to CECT in the detection of nodal recurrence. (orig.)

  4. Effects of population variability on the accuracy of detection probability estimates

    DEFF Research Database (Denmark)

    Ordonez Gloria, Alejandro

    2011-01-01

    Observing a constant fraction of the population over time, locations, or species is virtually impossible. Hence, quantifying this proportion (i.e. detection probability) is an important task in quantitative population ecology. In this study we determined, via computer simulations, the ef- fect of...

  5. Rapid, high-accuracy detection of strabismus and amblyopia using the pediatric vision scanner

    NARCIS (Netherlands)

    S.E. Loudon (Sjoukje); C.A. Rook (Caitlin); D.S. Nassif (Deborah); N.V. Piskun (Nadya); D.G. Hunter (David)

    2011-01-01

    textabstractPurpose. The Pediatric Vision Scanner (PVS) detects strabismus by identifying ocular fixation in both eyes simultaneously. This study was undertaken to assess the ability of the PVS to identify patients with amblyopia or strabismus, particularly anisometropic amblyopia with no measurable

  6. Accuracy analysis of the CTBTO nuclear test detection scale and Improvement

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Young Kwang [Seoul National Univ., Seoul (Korea, Republic of)

    2014-10-15

    CTBTO (Comprehensive nuclear Test Ban Treaty Organization) is charge of nuclear test monitoring for nuclear non-proliferation. CTBTO has 170 seismic stations in operation in 76 countries in order to detect the artificial earthquake that was caused by an underground nuclear test. Korea use formula that is based on the equations that are used by the IMS (International Monitoring System) of CTBTO for analysis of explosive scale, and reflect the nature of the terrain, such as rock. But the expression for calculating the exact scale explosive is still un-established state. And generally CTBTO doesn't care about artificial explosive that is being received low-yield in accordance with the criteria of nuclear detection. But, at the time that North Korea conduct a nuclear test, it should not be overlooked that the scale of the earthquake detection criteria below. Because DPRK is trying to conceal their nuclear development capability, there are possibility of low-yield nuclear test or possibility of install a buffer to hide actual explosive scale. These radionuclide observations were consistent with a DPRK low-yield nuclear test on May 2010, even though no seismic signals from such a test have been detected. But there were a few times of low-yield (magnitude 1.39-1.93) occurred around DPRK nuclear test site at that time.

  7. Telling friend from foe : Environmental cues improve detection accuracy of individuals with hostile intentions

    NARCIS (Netherlands)

    Wijn, Remco; van der Kleij, Rick; Kallen, Victor; Stekkinger, Michael; de Vries, Peter

    Purpose: Detecting deviant behaviours that precede and are related to crimes can help prevent these crimes. Research suggests that the psychological mindset of wrongdoers may differ from others, such that they are more anxious, self-focussed, and vigilant. As a result, their responses to

  8. Accuracy and Sensitivity of a Method of Jump Detection, Evaluated by Simulated Time Series

    Czech Academy of Sciences Publication Activity Database

    Chapanov, Y.; Ron, Cyril; Vondrák, Jan

    2017-01-01

    Roč. 14, č. 1 (2017), s. 73-82 ISSN 1214-9705 R&D Projects: GA ČR GA13-15943S Institutional support: RVO:67985815 Keywords : time series * data jump detection * high-sensitive method Subject RIV: DE - Earth Magnetism, Geodesy, Geography OBOR OECD: Physical geography Impact factor: 0.699, year: 2016

  9. Caregivers' attentional bias to pain : does it affect caregiver accuracy in detecting patient pain behaviors?

    NARCIS (Netherlands)

    Mohammadi, Somayyeh; Dehghani, Mohsen; Khatibi, Ali; Sanderman, Robbert; Hagedoorn, Mariet

    Attentional bias to pain among family caregivers of patients with pain may enhance the detection of pain behaviors in patients. However, both relatively high and low levels of attentional bias may increase disagreement between patients and caregivers in reporting pain behaviors. This study aims to

  10. Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Non-Cavitated Approximal Dental Caries

    International Nuclear Information System (INIS)

    Abesi, F.; Mirshekar, A.; Moudi, E.; Seyedmajidi, M.; Haghanifar, S.; Haghighat, N.; Bijani, A.

    2012-01-01

    Radiography plays an important role in the detection of interproximal caries. The aim of the present study was to determine diagnostic accuracy of charge coupled devices, Photo Stimulable Phosphor and film radiography in detecting non-cavitated caries. Seventy-two non-cavitated approximal surfaces of extracted human posterior teeth were radiographed under standardized conditions using three intraoral modalities: charge coupled devices Dixi3 (Planmeca, Finland), PSP Digora PCT (Soredex, Finland), and E-speed film (Kodak, USA). Radiographs were interpreted by four observers and caries lesions were classified as sound (R0), restricted to enamel (R1), reaching the dentinoenamel junction and the outer half of the dentin (R2) and the inner half of the dentin (R3). The teeth were subsequently sectioned for histological analysis which served as the gold standard for radiographic examination. Microscopic examinations showed that the distribution of caries were 63.9% sound, 18.1% enamel, 9.7% dentinoenamel junction and outer half of the dentin and 8.3% into the inner half of the dentin. The sensitivity and specificity of film, charge coupled devices and Photo Stimulable Phosphor for the detection of enamel caries were 38% and 98%; 15% and 96%; and 23% and 98%, respectively. The sensitivity and specificity of film, charge coupled devices and Photo Stimulable Phosphor for the detection of both dentin and enamel caries were 55% and 100%; 45% and 100% ; and 55% and 100%, respectively. The results demonstrated that the diagnostic accuracy of digital images is similar to that of conventional film radiography in the detection of non-cavitated approximal caries.

  11. Accuracy of carboxyhemoglobin detection by pulse CO-oximetry during hypoxemia.

    Science.gov (United States)

    Feiner, John R; Rollins, Mark D; Sall, Jeffrey W; Eilers, Helge; Au, Paul; Bickler, Philip E

    2013-10-01

    Carbon monoxide poisoning is a significant problem in most countries, and a reliable method of quick diagnosis would greatly improve patient care. Until the recent introduction of a multiwavelength "pulse CO-oximeter" (Masimo Rainbow SET(®) Radical-7), obtaining carboxyhemoglobin (COHb) levels in blood required blood sampling and laboratory analysis. In this study, we sought to determine whether hypoxemia, which can accompany carbon monoxide poisoning, interferes with the accurate detection of COHb. Twelve healthy, nonsmoking, adult volunteers were fitted with 2 standard pulse-oximeter finger probes and 2 Rainbow probes for COHb detection. A radial arterial catheter was placed for blood sampling during 3 interventions: (1) increasing hypoxemia in incremental steps with arterial oxygen saturations (SaO2) of 100% to 80%; (2) normoxia with incremental increases in %COHb to 12%; and (3) elevated COHb combined with hypoxemia with SaO2 of 100% to 80%. Pulse-oximeter (SpCO) readings were compared with simultaneous arterial blood values at the various increments of hypoxemia and carboxyhemoglobinemia (≈25 samples per subject). Pulse CO-oximeter performance was analyzed by calculating the mean bias (SpCO - %COHb), standard deviation of the bias (precision), and the root-mean-square error (A(rms)). The Radical-7 accurately detected hypoxemia with both normal and elevated levels of COHb (bias mean ± SD: 0.44% ± 1.69% at %COHb <4%, and -0.29% ± 1.64% at %COHb ≥4%, P < 0.0001, and A(rms) 1.74% vs 1.67%). COHb was accurately detected during normoxia and moderate hypoxia (bias mean ± SD: -0.98 ± 2.6 at SaO2 ≥95%, and -0.7 ± 4.0 at SaO2 <95%, P = 0.60, and A(rms) 2.8% vs 4.0%), but when SaO2 decreased below approximately 85%, the pulse CO-oximeter always gave low signal quality errors and did not report SpCO values. In healthy volunteers, the Radical-7 pulse CO-oximeter accurately detects hypoxemia with both low and elevated COHb levels, and accurately detects COHb

  12. Spatial and temporal accuracy of asynchrony-tolerant finite difference schemes for partial differential equations at extreme scales

    Science.gov (United States)

    Kumari, Komal; Donzis, Diego

    2017-11-01

    Highly resolved computational simulations on massively parallel machines are critical in understanding the physics of a vast number of complex phenomena in nature governed by partial differential equations. Simulations at extreme levels of parallelism present many challenges with communication between processing elements (PEs) being a major bottleneck. In order to fully exploit the computational power of exascale machines one needs to devise numerical schemes that relax global synchronizations across PEs. This asynchronous computations, however, have a degrading effect on the accuracy of standard numerical schemes.We have developed asynchrony-tolerant (AT) schemes that maintain order of accuracy despite relaxed communications. We show, analytically and numerically, that these schemes retain their numerical properties with multi-step higher order temporal Runge-Kutta schemes. We also show that for a range of optimized parameters,the computation time and error for AT schemes is less than their synchronous counterpart. Stability of the AT schemes which depends upon history and random nature of delays, are also discussed. Support from NSF is gratefully acknowledged.

  13. Retrieval Accuracy Assessment with Gap Detection for Case 2 Waters Chla Algorithms

    Science.gov (United States)

    Salem, S. I.; Higa, H.; Kim, H.; Oki, K.; Oki, T.

    2016-12-01

    Inland lakes and coastal regions types of Case 2 Waters should be continuously and accurately monitored as the former contain 90% of the global liquid freshwater storage, while the latter provide most of the dissolved organic carbon (DOC) which is an important link in the global carbon cycle. The optical properties of Case 2 Waters are dominated by three optically active components: phytoplankton, non-algal particles (NAP) and color dissolved organic matter (CDOM). During the last three decades, researchers have proposed several algorithms to retrieve Chla concentration from the remote sensing reflectance. In this study, seven algorithms are assessed with various band combinations from multi and hyper-spectral data with linear, polynomial and power regression approaches. To evaluate the performance of the 43 algorithm combination sets, 500,000 remote sensing reflectance spectra are simulated with a wide range of concentrations for Chla, NAP and CDOM. The concentrations of Chla and NAP vary from 1-200 (mg m-3) and 1-200 (gm m-3), respectively, and the absorption of CDOM at 440 nm has the range of 0.1-10 (m-1). It is found that the three-band algorithm (665, 709 and 754 nm) with the quadratic polynomial (3b_665_QP) indicates the best overall performance. 3b_665_QP has the least error with a root mean square error (RMSE) of 0.2 (mg m-3) and a mean absolute relative error (MARE) of 0.7 %. The less accurate retrieval of Chla was obtained by the synthetic chlorophyll index algorithm with RMSE and MARE of 35.8 mg m-3 and 160.4 %, respectively. In general, Chla algorithms which incorporates 665 nm band or band tuning technique performs better than those with 680 nm. In addition, the retrieval accuracy of Chla algorithms with quadratic polynomial and power regression approaches are consistently better than the linear ones. By analyzing Chla versus NAP concentrations, the 3b_665_QP outperforms the other algorithms for all Chla concentrations and NAP concentrations above 40

  14. The accuracy of combined physical examination and ultrasonography for the detection of abdominal aorta aneurysm.

    Science.gov (United States)

    Cârstea, Doina; Streba, Letiţia Adela Maria; Glodeanu, Adina; Cârstea, A P; Vancu, Mihaela; Ninulescu, Ana-Maria

    2008-01-01

    Atherosclerosis is the most frequent cause in the appearance of an abdominal aorta aneurysm (AAA) and plays an important role in his development. Most AAA does not cause any symptoms, especially when talking about elderly patients, however, many of those aneurysms can be detected during physical examination. Their detection is very important because the natural evolution and the major reason in treating AAA is their tendency to rupture. We present the case of an adult man with a complex clinical pathology, but not related to the AAA. The diagnosis of the AAA has been suspicion through palpation, and the abdominal ultrasound exam confirmed it. This case is particular interesting, as the AAA requires surgical intervention, while patient's health status was poor. An essential issue is establishing the importance of the AAA screening, when there are no symptoms present. For now, there are not satisfactory studies to be used as a guide.

  15. Rapid, high-accuracy detection of strabismus and amblyopia using the pediatric vision scanner

    OpenAIRE

    Loudon, Sjoukje; Rook, Caitlin; Nassif, Deborah; Piskun, Nadya; Hunter, David

    2011-01-01

    textabstractPurpose. The Pediatric Vision Scanner (PVS) detects strabismus by identifying ocular fixation in both eyes simultaneously. This study was undertaken to assess the ability of the PVS to identify patients with amblyopia or strabismus, particularly anisometropic amblyopia with no measurable strabismus. Methods. The PVS test, administered from 40 cm and requiring 2.5 seconds of attention, generated a binocularity score (BIN, 0%-100%). We tested 154 patients and 48 controls between the...

  16. Reflotron cholesterol measurement in general practice: accuracy and detection of errors.

    Science.gov (United States)

    Ball, M J; Robertson, I K; Woods, M

    1994-11-01

    Comparison of cholesterol determinations by nurses using a Reflotron analyser in a general practice setting showed a good correlation with plasma cholesterol determinations by wet chemistry in a clinical biochemistry laboratory. A limited number of comparisons did, however, give a much lower result on the Reflotron. In an experimental situation, small sample volumes (which could result from poor technique) were shown to produce falsely low readings. A simple method which may immediately detect falsely low Reflotron readings is discussed.

  17. Multi-class geospatial object detection based on a position-sensitive balancing framework for high spatial resolution remote sensing imagery

    Science.gov (United States)

    Zhong, Yanfei; Han, Xiaobing; Zhang, Liangpei

    2018-04-01

    Multi-class geospatial object detection from high spatial resolution (HSR) remote sensing imagery is attracting increasing attention in a wide range of object-related civil and engineering applications. However, the distribution of objects in HSR remote sensing imagery is location-variable and complicated, and how to accurately detect the objects in HSR remote sensing imagery is a critical problem. Due to the powerful feature extraction and representation capability of deep learning, the deep learning based region proposal generation and object detection integrated framework has greatly promoted the performance of multi-class geospatial object detection for HSR remote sensing imagery. However, due to the translation caused by the convolution operation in the convolutional neural network (CNN), although the performance of the classification stage is seldom influenced, the localization accuracies of the predicted bounding boxes in the detection stage are easily influenced. The dilemma between translation-invariance in the classification stage and translation-variance in the object detection stage has not been addressed for HSR remote sensing imagery, and causes position accuracy problems for multi-class geospatial object detection with region proposal generation and object detection. In order to further improve the performance of the region proposal generation and object detection integrated framework for HSR remote sensing imagery object detection, a position-sensitive balancing (PSB) framework is proposed in this paper for multi-class geospatial object detection from HSR remote sensing imagery. The proposed PSB framework takes full advantage of the fully convolutional network (FCN), on the basis of a residual network, and adopts the PSB framework to solve the dilemma between translation-invariance in the classification stage and translation-variance in the object detection stage. In addition, a pre-training mechanism is utilized to accelerate the training procedure

  18. Accuracy of detecting stenotic changes on coronary cineangiograms using computer image processing

    International Nuclear Information System (INIS)

    Sugahara, Tetsuo; Kimura, Koji; Maeda, Hirofumi.

    1990-01-01

    To accurately interprets stenotic changes on coronary cineangiograms, an automatic method of detecting stenotic lesion using computer image processing was developed. First, tracing of artery was performed. The vessel edges were then determined by unilateral Gaussian fitting. The stenotic change was detected on the basis of the reference diameter estimated by Hough transformation. This method was evaluated in 132 segments of 27 arteries in 18 patients. Three observers carried out visual interpretation and computer-aided interpretation. The rate of detection by visual interpretation was 6.1, 28.8 and 20.5%, and by computer-aided interpretation, 39.4, 39.4 and 45.5%. With computer-aided interpretation, the agreement between any two observers on lesions and non-lesions was 40.2% and 59.8%, respectively. Therefore, visual interpretation tended to underestimate the stenotic changes on coronary cineangiograms. We think that computer-aided interpretation increase the reliability of diagnosis on coronary cineangiograms. (author)

  19. An Object-Based Image Analysis Approach for Detecting Penguin Guano in very High Spatial Resolution Satellite Images

    Directory of Open Access Journals (Sweden)

    Chandi Witharana

    2016-04-01

    Full Text Available The logistical challenges of Antarctic field work and the increasing availability of very high resolution commercial imagery have driven an interest in more efficient search and classification of remotely sensed imagery. This exploratory study employed geographic object-based analysis (GEOBIA methods to classify guano stains, indicative of chinstrap and Adélie penguin breeding areas, from very high spatial resolution (VHSR satellite imagery and closely examined the transferability of knowledge-based GEOBIA rules across different study sites focusing on the same semantic class. We systematically gauged the segmentation quality, classification accuracy, and the reproducibility of fuzzy rules. A master ruleset was developed based on one study site and it was re-tasked “without adaptation” and “with adaptation” on candidate image scenes comprising guano stains. Our results suggest that object-based methods incorporating the spectral, textural, spatial, and contextual characteristics of guano are capable of successfully detecting guano stains. Reapplication of the master ruleset on candidate scenes without modifications produced inferior classification results, while adapted rules produced comparable or superior results compared to the reference image. This work provides a road map to an operational “image-to-assessment pipeline” that will enable Antarctic wildlife researchers to seamlessly integrate VHSR imagery into on-demand penguin population census.

  20. Diagnostic accuracy of the detection of bone change using panoramic TMJ projection. Comparative study with limited cone-beam CT

    International Nuclear Information System (INIS)

    Araki, Kazuyuki; Okano, Tomohiro; Kataoka, Ryuta; Honda, Kazuya; Endo, Atsushi; Kaneko, Norikazu; Funahashi, Itsuo

    2008-01-01

    Panoramic temporoman joint (TMJ) projection is one of the alternative methods of conventional radiography, such as transcranial projection, for diagnosing temporomandibular joint disorder. There have been a few reports describing the diagnostic ability of this method. We evaluated the diagnostic accuracy of detecting bone change with panoramic TMJ projection. Fifty TMJs in 25 patients were examined. All TMJs were examined by panoramic TMJ projection (Hyper XF) and limited cone-beam CT (3D Accuitomo FPD; 3DX). Two observers evaluated the presence of bone change in the TMJ region using panoramic TMJ projection. One other observer evaluated the limited cone-beam CT for the presence and the pattern of bone changes in the TMJ region as the gold standard. Panoramic TMJ findings were evaluated with regard to sensitivity, specificity, and accuracy. Sensitivity, specificity and accuracy of the panoramic TMJ projection were 0.86, 0.76, and 0.82, respectively. These results and those of previous reports on other radiographic methods for TMJ suggest that panoramic TMJ projection is a useful method of screening for bone change due to TMJ disorder. (author)

  1. Research on photodiode detector-based spatial transient light detection and processing system

    Science.gov (United States)

    Liu, Meiying; Wang, Hu; Liu, Yang; Zhao, Hui; Nan, Meng

    2016-10-01

    In order to realize real-time signal identification and processing of spatial transient light, the features and the energy of the captured target light signal are first described and quantitatively calculated. Considering that the transient light signal has random occurrence, a short duration and an evident beginning and ending, a photodiode detector based spatial transient light detection and processing system is proposed and designed in this paper. This system has a large field of view and is used to realize non-imaging energy detection of random, transient and weak point target under complex background of spatial environment. Weak signal extraction under strong background is difficult. In this paper, considering that the background signal changes slowly and the target signal changes quickly, filter is adopted for signal's background subtraction. A variable speed sampling is realized by the way of sampling data points with a gradually increased interval. The two dilemmas that real-time processing of large amount of data and power consumption required by the large amount of data needed to be stored are solved. The test results with self-made simulative signal demonstrate the effectiveness of the design scheme. The practical system could be operated reliably. The detection and processing of the target signal under the strong sunlight background was realized. The results indicate that the system can realize real-time detection of target signal's characteristic waveform and monitor the system working parameters. The prototype design could be used in a variety of engineering applications.

  2. Comparisons of lesion detectability in ultrasound images acquired using time-shift compensation and spatial compounding.

    Science.gov (United States)

    Lacefield, James C; Pilkington, Wayne C; Waag, Robert C

    2004-12-01

    The effects of aberration, time-shift compensation, and spatial compounding on the discrimination of positive-contrast lesions in ultrasound b-scan images are investigated using a two-dimensional (2-D) array system and tissue-mimicking phantoms. Images were acquired within an 8.8 x 12-mm2 field of view centered on one of four statistically similar 4-mm diameter spherical lesions. Each lesion was imaged in four planes offset by successive 45 degree rotations about the central scan line. Images of the lesions were acquired using conventional geometric focusing through a water path, geometric focusing through a 35-mm thick distributed aberration phantom, and time-shift compensated transmit and receive focusing through the aberration phantom. The views of each lesion were averaged to form sets of water path, aberrated, and time-shift compensated 4:1 compound images and 16:1 compound images. The contrast ratio and detectability index of each image were computed to assess lesion differentiation. In the presence of aberration representative of breast or abdominal wall tissue, time-shift compensation provided statistically significant improvements of contrast ratio but did not consistently affect the detectability index, and spatial compounding significantly increased the detectability index but did not alter the contrast ratio. Time-shift compensation and spatial compounding thus provide complementary benefits to lesion detection.

  3. Experimental study on the crack detection with optimized spatial wavelet analysis and windowing

    Science.gov (United States)

    Ghanbari Mardasi, Amir; Wu, Nan; Wu, Christine

    2018-05-01

    In this paper, a high sensitive crack detection is experimentally realized and presented on a beam under certain deflection by optimizing spatial wavelet analysis. Due to the crack existence in the beam structure, a perturbation/slop singularity is induced in the deflection profile. Spatial wavelet transformation works as a magnifier to amplify the small perturbation signal at the crack location to detect and localize the damage. The profile of a deflected aluminum cantilever beam is obtained for both intact and cracked beams by a high resolution laser profile sensor. Gabor wavelet transformation is applied on the subtraction of intact and cracked data sets. To improve detection sensitivity, scale factor in spatial wavelet transformation and the transformation repeat times are optimized. Furthermore, to detect the possible crack close to the measurement boundaries, wavelet transformation edge effect, which induces large values of wavelet coefficient around the measurement boundaries, is efficiently reduced by introducing different windowing functions. The result shows that a small crack with depth of less than 10% of the beam height can be localized with a clear perturbation. Moreover, the perturbation caused by a crack at 0.85 mm away from one end of the measurement range, which is covered by wavelet transform edge effect, emerges by applying proper window functions.

  4. Spatial eigensolution analysis of energy-stable flux reconstruction schemes and influence of the numerical flux on accuracy and robustness

    Science.gov (United States)

    Mengaldo, Gianmarco; De Grazia, Daniele; Moura, Rodrigo C.; Sherwin, Spencer J.

    2018-04-01

    This study focuses on the dispersion and diffusion characteristics of high-order energy-stable flux reconstruction (ESFR) schemes via the spatial eigensolution analysis framework proposed in [1]. The analysis is performed for five ESFR schemes, where the parameter 'c' dictating the properties of the specific scheme recovered is chosen such that it spans the entire class of ESFR methods, also referred to as VCJH schemes, proposed in [2]. In particular, we used five values of 'c', two that correspond to its lower and upper bounds and the others that identify three schemes that are linked to common high-order methods, namely the ESFR recovering two versions of discontinuous Galerkin methods and one recovering the spectral difference scheme. The performance of each scheme is assessed when using different numerical intercell fluxes (e.g. different levels of upwinding), ranging from "under-" to "over-upwinding". In contrast to the more common temporal analysis, the spatial eigensolution analysis framework adopted here allows one to grasp crucial insights into the diffusion and dispersion properties of FR schemes for problems involving non-periodic boundary conditions, typically found in open-flow problems, including turbulence, unsteady aerodynamics and aeroacoustics.

  5. A Review On Accuracy and Uncertainty of Spatial Data and Analyses with special reference to Urban and Hydrological Modelling

    Science.gov (United States)

    Devendran, A. A.; Lakshmanan, G.

    2014-11-01

    Data quality for GIS processing and analysis is becoming an increased concern due to the accelerated application of GIS technology for problem solving and decision making roles. Uncertainty in the geographic representation of the real world arises as these representations are incomplete. Identification of the sources of these uncertainties and the ways in which they operate in GIS based representations become crucial in any spatial data representation and geospatial analysis applied to any field of application. This paper reviews the articles on the various components of spatial data quality and various uncertainties inherent in them and special focus is paid to two fields of application such as Urban Simulation and Hydrological Modelling. Urban growth is a complicated process involving the spatio-temporal changes of all socio-economic and physical components at different scales. Cellular Automata (CA) model is one of the simulation models, which randomly selects potential cells for urbanisation and the transition rules evaluate the properties of the cell and its neighbour. Uncertainty arising from CA modelling is assessed mainly using sensitivity analysis including Monte Carlo simulation method. Likewise, the importance of hydrological uncertainty analysis has been emphasized in recent years and there is an urgent need to incorporate uncertainty estimation into water resources assessment procedures. The Soil and Water Assessment Tool (SWAT) is a continuous time watershed model to evaluate various impacts of land use management and climate on hydrology and water quality. Hydrological model uncertainties using SWAT model are dealt primarily by Generalized Likelihood Uncertainty Estimation (GLUE) method.

  6. Early non-destructive biofouling detection and spatial distribution: Application of oxygen sensing optodes

    KAUST Repository

    Farhat, Nadia

    2015-06-11

    Biofouling is a serious problem in reverse osmosis/nanofiltration (RO/NF) applications, reducing membrane performance. Early detection of biofouling plays an essential role in an adequate anti-biofouling strategy. Presently, fouling of membrane filtration systems is mainly determined by measuring changes in pressure drop, which is not exclusively linked to biofouling. Non-destructive imaging of oxygen concentrations (i) is specific for biological activity of biofilms and (ii) may enable earlier detection of biofilm accumulation than pressure drop. The objective of this study was to test whether transparent luminescent planar O2 optodes, in combination with a simple imaging system, can be used for early non-destructive biofouling detection. This biofouling detection is done by mapping the two-dimensional distribution of O2 concentrations and O2 decrease rates inside a membrane fouling simulator (MFS). Results show that at an early stage, biofouling development was detected by the oxygen sensing optodes while no significant increase in pressure drop was yet observed. Additionally, optodes could detect spatial heterogeneities in biofouling distribution at a micro scale. Biofilm development started mainly at the feed spacer crossings. The spatial and quantitative information on biological activity will lead to better understanding of the biofouling processes, contributing to the development of more effective biofouling control strategies.

  7. The analysis of the accuracy of spatial models using photogrammetric software: Agisoft Photoscan and Pix4D

    Directory of Open Access Journals (Sweden)

    Barbasiewicz Adrianna

    2018-01-01

    Full Text Available This article was created as a result of research conducted within the master thesis. The purpose of the measurements was to analyze the accuracy of the positioning of points by computer programs. Selected software was a specialized computer software dedicated to photogrammetric work. For comparative purposes it was decided to use tools with similar functionality. As the basic parameters that affect the results selected the resolution of the photos on which the key points were searched. In order to determine the location of the determined points, it was decided to follow the photogrammetric resection rule. In order to automate the measurement, the measurement session planning was omitted. The coordinates of the points collected by the tachymetric measure were used as a reference system. The resulting deviations and linear displacements oscillate in millimeters. The visual aspects of the cloud points have also been briefly analyzed.

  8. The analysis of the accuracy of spatial models using photogrammetric software: Agisoft Photoscan and Pix4D

    Science.gov (United States)

    Barbasiewicz, Adrianna; Widerski, Tadeusz; Daliga, Karol

    2018-01-01

    This article was created as a result of research conducted within the master thesis. The purpose of the measurements was to analyze the accuracy of the positioning of points by computer programs. Selected software was a specialized computer software dedicated to photogrammetric work. For comparative purposes it was decided to use tools with similar functionality. As the basic parameters that affect the results selected the resolution of the photos on which the key points were searched. In order to determine the location of the determined points, it was decided to follow the photogrammetric resection rule. In order to automate the measurement, the measurement session planning was omitted. The coordinates of the points collected by the tachymetric measure were used as a reference system. The resulting deviations and linear displacements oscillate in millimeters. The visual aspects of the cloud points have also been briefly analyzed.

  9. Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsdottir, Sigurdis, E-mail: sigurdisha@gmail.com [Boston Medical Center, 72 East Concord Street (Evans 124), Boston, MA, 02118 (United States); Gudnason, Thorarinn, E-mail: thorgudn@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Sigurdsson, Axel F., E-mail: axelfsig@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gudjonsdottir, Jonina, E-mail: jonina@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Lehman, Sam J., E-mail: slehman@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Eyjolfsson, Kristjan, E-mail: kristey@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Scheving, Sigurpall S., E-mail: sigurpal@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gibson, C. Michael, E-mail: mgibson@perfuse.org [Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115 (United States); Hoffmann, Udo, E-mail: uhoffmann@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Jonsdottir, Birna, E-mail: birna@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Andersen, Karl, E-mail: andersen@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland)

    2010-11-15

    Objectives: To investigate the diagnostic accuracy of 64-slice multidetector computed tomography (64-CT) for detection of in-stent restenosis (ISR) in an unselected, consecutive patient population. Background: Detection of in-stent restenosis by cardiac CT would be a major advance for the evaluation of patients suspected of having ISR. However, the diagnostic accuracy of current generation 64-CT in this context is not fully established. Methods: We conducted a prospective study on patients with stable angina or acute coronary syndrome with no prior history of coronary artery disease. Six months after percutaneous coronary intervention (PCI) with stent placement they underwent a 64-CT scan (Toshiba Multi-Slice Aquilion 64) and consequently a repeat coronary angiography for comparison. Cardiac CT data sets were analyzed for the presence of in-stent restenosis by two independent expert readers blinded to the coronary angiographic data. Results: Ninety-three patients with a total of 140 stents were evaluated. Males comprised 82% of the study group and the mean age was 63 {+-} 10 years. The mean time from PCI to the repeat coronary angiography was 208 {+-} 37 days and the mean time from 64-CT to repeat coronary angiography was 3.7 {+-} 4.9 days. The restenosis rate according to coronary angiography was 26%. Stent diameter, strut thickness, heart rate and body mass index (BMI) significantly affected image quality. The sensitivity, specificity, positive and negative predictive values of 64-CT for detection of in-stent restenosis were 27%, 95%, 67% and 78%, respectively. Conclusions: Current generation, 64-slice CT, remains limited in its ability to accurately detect in-stent restenosis.

  10. Diagnostic accuracy of point shear wave elastography in the detection of portal hypertension in pediatric patients.

    Science.gov (United States)

    Burak Özkan, M; Bilgici, M C; Eren, E; Caltepe, G

    2018-03-01

    The purpose of this study was to determine the usefulness of point shear wave elastography (p-SWE) of the liver and spleen for the detection of portal hypertension in pediatric patients. The study consisted of 38 healthy children and 56 pediatric patients with biopsy-proven liver disease who underwent splenic and liver p-SWE. The diagnostic performance of p-SWE in detecting clinically significant portal hypertension was assessed using receiver operating characteristic (ROC) curves. Reliable measurements of splenic and liver stiffness with p-SWE were obtained in 76/94 (81%) and 80/94 patients (85%), respectively. The splenic stiffness was highest in the portal hypertension group (Pportal hypertension was lower for splenic p-SWE than for liver p-SWE (0.906 vs. 0.746; P=0.0239). The cut-off value of splenic p-SWE for portal hypertension was 3.14m/s, with a specificity of 98.59% and a sensitivity of 68.18%. The cut-off value of liver p-SWE for portal hypertension was 2.09m/s, with a specificity of 80.28% and a sensitivity of 77.27%. In pediatric patients, p-SWE is a reliable method for detecting portal hypertension. However, splenic p-SWE is less accurate than liver p-SWE for the diagnosis of portal hypertension. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. The accuracy of CT and tumor markers in the detection of a recurrent ovarian carcinoma

    International Nuclear Information System (INIS)

    Wakabayashi, Yukari; Ishida, Jiro; Kotake, Fumio; Hirose, Masahiro; Kawana, Koji; Abe, Kimihiko; Amino, Saburo; Negishi, Yoshiyuki; Akiya, Kiyoshi

    1989-01-01

    Twenty-three patients previously diagnosed as having ovarian cancer were examined with both serum tumor markers (CA 125, CA 19-9, TPA, IAP, AFP) and a pelvic CT scan. The tumor markers predict the clinical outcome more accurately than the CT scan. Further, the tumor markers showed a clear correlation with the clinical course. But in one case, however, the tumor markers were seen to reduce below the normal level from chemotherapy, while the CT scan showed a tumor mass. Thus, both, a CT scan and tumor marker assays are felt to be indispensable for detecting the recurrence of an ovarian cancer. (author)

  12. Accuracy of pulmonary auscultation to detect abnormal respiratory mechanics: a cross-sectional diagnostic study.

    Science.gov (United States)

    Xavier, Glaciele Nascimento; Duarte, Antonio Carlos Magalhães; Melo-Silva, César Augusto; dos Santos, Carlos Eduardo Ventura Gaio; Amado, Veronica Moreira

    2014-12-01

    Pulmonary auscultation is a method used in clinical practice for the evaluation and detection of abnormalities relating to the respiratory system. This method has limitations, as it depends on the experience and hearing acuity of the examiner to determine adventitious sounds. In this context, it's important to analyze whether there is a correlation between auscultation of lung sounds and the behavior of the respiratory mechanical properties of the respiratory system in patients with immediate postoperative cardiac surgery. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Detecting representative data and generating synthetic samples to improve learning accuracy with imbalanced data sets.

    Directory of Open Access Journals (Sweden)

    Der-Chiang Li

    Full Text Available It is difficult for learning models to achieve high classification performances with imbalanced data sets, because with imbalanced data sets, when one of the classes is much larger than the others, most machine learning and data mining classifiers are overly influenced by the larger classes and ignore the smaller ones. As a result, the classification algorithms often have poor learning performances due to slow convergence in the smaller classes. To balance such data sets, this paper presents a strategy that involves reducing the sizes of the majority data and generating synthetic samples for the minority data. In the reducing operation, we use the box-and-whisker plot approach to exclude outliers and the Mega-Trend-Diffusion method to find representative data from the majority data. To generate the synthetic samples, we propose a counterintuitive hypothesis to find the distributed shape of the minority data, and then produce samples according to this distribution. Four real datasets were used to examine the performance of the proposed approach. We used paired t-tests to compare the Accuracy, G-mean, and F-measure scores of the proposed data pre-processing (PPDP method merging in the D3C method (PPDP+D3C with those of the one-sided selection (OSS, the well-known SMOTEBoost (SB study, and the normal distribution-based oversampling (NDO approach, and the proposed data pre-processing (PPDP method. The results indicate that the classification performance of the proposed approach is better than that of above-mentioned methods.

  14. Diagnostic accuracy of metronome-paced tachypnea to detect dynamic hyperinflation.

    Science.gov (United States)

    Lahaije, Anke J M C; Willems, Laura M; van Hees, Hieronymus W H; Dekhuijzen, P N Richard; van Helvoort, Hanneke A C; Heijdra, Yvonne F

    2013-01-01

    This prospective study was carried out to investigate if metronome-paced tachypnea (MPT) can serve as an accurate diagnostic tool to identify patients with chronic obstructive pulmonary disease (COPD) who are susceptible to develop dynamic hyperinflation during exercise. Commonly, this is assessed by measuring change in inspiratory capacity (IC) during cardiopulmonary exercise testing (CPET), which, however, is complex and laborious. Fifty-three patients with COPD (FEV(1) 58 ± 22%pred) and 20 age-matched healthy subjects were characterized by lung function testing and performed CPET (reference standard) and MPT. The repeatability coefficient of IC (10·2%) was used as cut-off to classify subjects as hyperinflators during CPET. Subsequently, dynamic hyperinflation was measured after MPT. With receiver operating characteristic analysis, the optimal cut-off for MPT-induced dynamic hyperinflation was determined and sensitivity and specificity of MPT to identify hyperinflators were evaluated. With 10·2% decrease in IC as cut-off for CPET-induced dynamic hyperinflation, the optimal cut-off for MPT was 11·1% decrease in IC. Using these cut-offs, MPT had a sensitivity of 85% and specificity of 85% to identify the subjects who hyperinflated during CPET. The MPT test shows good overall accuracy to identify subjects who are susceptible to develop dynamic hyperinflation during CPET. Before considering the use of MPT as a screening tool for dynamic hyperinflation in COPD, sensitivity and specificity need further evaluation. © 2012 The Authors Clinical Physiology and Functional Imaging © 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  15. Accuracy of multidetector CT in detecting anastomotic leaks following stapled left-sided colonic anastomosis

    International Nuclear Information System (INIS)

    Kaur, P.; Karandikar, S.S.; Roy-Choudhury, S.

    2014-01-01

    Aims: To assess accuracy of multidetector computed tomography (MDCT) and individual radiological signs in the diagnosis of anastomotic leaks. Materials and methods: Patients undergoing anterior resection with a stapled anastomosis over a 2 year period were identified. Electronic and clinical records of these patients were reviewed. Unenhanced and/or enhanced MDCT was performed with intravenous and/or per-rectal contrast medium and read by a radiologist blinded to the patients' clinical details to determine the sensitivity and specificity of specific findings at MDCT for identifying leaks. Results: Seventeen percent (30/170) of the anterior resections were suspected to have an anastomotic leak. Ninety-three percent (28/30) of patients underwent MDCT. Seven point six percent (11+2/170) had a confirmed leak. Two patients underwent surgery without MDCT. A leak was confirmed by MDCT in 91% (10/11) of patients. The sensitivity, specificity, and positive and negative predictive values of MDCT in diagnosing a leak was 0.91, 1, 1, and 0.95, respectively. The sensitivity of peri-anastomotic air, peri-anastomotic collection, extravasation of rectal contrast medium, and staple line integrity was 0.81, 0.63, 0.54, and 0.72, respectively. Use of rectal contrast medium (8/11 cases) increased the subjective ease of diagnosis and was the only sign in one patient. Conclusions: Presence of peri-anastomotic air is a reliable marker of anastomotic leaks at MDCT. Leakage of rectal contrast medium is highly accurate and increases confidence of diagnosis. The appearance of the staple line itself is not accurate in assessing anastomotic integrity

  16. Diagnostic accuracy of phosphor plate systems and conventional radiography in the detection of simulated internal root resorption.

    Science.gov (United States)

    Vasconcelos, Karla de Faria; Rovaris, Karla; Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Távora, Débora de Melo; Bóscolo, Frab Norberto

    2017-11-01

    To evaluate the performance of conventional radiography and photostimulable phosphor (PSP) plate in the detection of simulated internal root resorption (IRR) lesions in early stages. Twenty single-rooted teeth were X-rayed before and after having a simulated IRR early lesion. Three imaging systems were used: Kodak InSight dental film and two PSPs digital systems, Digora Optime and VistaScan. The digital images were displayed on a 20.1″ LCD monitor using the native software of each system, and the conventional radiographs were evaluated on a masked light box. Two radiologists were asked to indicate the presence or absence of IRR and, after two weeks, all images were re-evaluated. Cohen's kappa coefficient was calculated to assess intra- and interobserver agreement. The three imaging systems were compared using the Kruskal-Wallis test. For interexaminer agreement, overall kappa values were 0.70, 0.65 and 0.70 for conventional film, Digora Optima and VistaScan, respectively. Both the conventional and digital radiography presented low sensitivity, specificity, accuracy, positive and negative predictive values with no significant difference between imaging systems (p = .0725). The performance of conventional and PSP was similar in the detection of simulated IRR lesions in early stages with low accuracy.

  17. Mediastinal lymph node detection and station mapping on chest CT using spatial priors and random forest

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jiamin; Hoffman, Joanne; Zhao, Jocelyn; Yao, Jianhua; Lu, Le; Kim, Lauren; Turkbey, Evrim B.; Summers, Ronald M., E-mail: rms@nih.gov [Imaging Biomarkers and Computer-aided Diagnosis Laboratory, Radiology and Imaging Sciences, National Institutes of Health Clinical Center Building, 10 Room 1C224 MSC 1182, Bethesda, Maryland 20892-1182 (United States)

    2016-07-15

    Purpose: To develop an automated system for mediastinal lymph node detection and station mapping for chest CT. Methods: The contextual organs, trachea, lungs, and spine are first automatically identified to locate the region of interest (ROI) (mediastinum). The authors employ shape features derived from Hessian analysis, local object scale, and circular transformation that are computed per voxel in the ROI. Eight more anatomical structures are simultaneously segmented by multiatlas label fusion. Spatial priors are defined as the relative multidimensional distance vectors corresponding to each structure. Intensity, shape, and spatial prior features are integrated and parsed by a random forest classifier for lymph node detection. The detected candidates are then segmented by the following curve evolution process. Texture features are computed on the segmented lymph nodes and a support vector machine committee is used for final classification. For lymph node station labeling, based on the segmentation results of the above anatomical structures, the textual definitions of mediastinal lymph node map according to the International Association for the Study of Lung Cancer are converted into patient-specific color-coded CT image, where the lymph node station can be automatically assigned for each detected node. Results: The chest CT volumes from 70 patients with 316 enlarged mediastinal lymph nodes are used for validation. For lymph node detection, their system achieves 88% sensitivity at eight false positives per patient. For lymph node station labeling, 84.5% of lymph nodes are correctly assigned to their stations. Conclusions: Multiple-channel shape, intensity, and spatial prior features aggregated by a random forest classifier improve mediastinal lymph node detection on chest CT. Using the location information of segmented anatomic structures from the multiatlas formulation enables accurate identification of lymph node stations.

  18. Mediastinal lymph node detection and station mapping on chest CT using spatial priors and random forest

    International Nuclear Information System (INIS)

    Liu, Jiamin; Hoffman, Joanne; Zhao, Jocelyn; Yao, Jianhua; Lu, Le; Kim, Lauren; Turkbey, Evrim B.; Summers, Ronald M.

    2016-01-01

    Purpose: To develop an automated system for mediastinal lymph node detection and station mapping for chest CT. Methods: The contextual organs, trachea, lungs, and spine are first automatically identified to locate the region of interest (ROI) (mediastinum). The authors employ shape features derived from Hessian analysis, local object scale, and circular transformation that are computed per voxel in the ROI. Eight more anatomical structures are simultaneously segmented by multiatlas label fusion. Spatial priors are defined as the relative multidimensional distance vectors corresponding to each structure. Intensity, shape, and spatial prior features are integrated and parsed by a random forest classifier for lymph node detection. The detected candidates are then segmented by the following curve evolution process. Texture features are computed on the segmented lymph nodes and a support vector machine committee is used for final classification. For lymph node station labeling, based on the segmentation results of the above anatomical structures, the textual definitions of mediastinal lymph node map according to the International Association for the Study of Lung Cancer are converted into patient-specific color-coded CT image, where the lymph node station can be automatically assigned for each detected node. Results: The chest CT volumes from 70 patients with 316 enlarged mediastinal lymph nodes are used for validation. For lymph node detection, their system achieves 88% sensitivity at eight false positives per patient. For lymph node station labeling, 84.5% of lymph nodes are correctly assigned to their stations. Conclusions: Multiple-channel shape, intensity, and spatial prior features aggregated by a random forest classifier improve mediastinal lymph node detection on chest CT. Using the location information of segmented anatomic structures from the multiatlas formulation enables accurate identification of lymph node stations.

  19. Evaluating species richness: biased ecological inference results from spatial heterogeneity in species detection probabilities

    Science.gov (United States)

    McNew, Lance B.; Handel, Colleen M.

    2015-01-01

    Accurate estimates of species richness are necessary to test predictions of ecological theory and evaluate biodiversity for conservation purposes. However, species richness is difficult to measure in the field because some species will almost always be overlooked due to their cryptic nature or the observer's failure to perceive their cues. Common measures of species richness that assume consistent observability across species are inviting because they may require only single counts of species at survey sites. Single-visit estimation methods ignore spatial and temporal variation in species detection probabilities related to survey or site conditions that may confound estimates of species richness. We used simulated and empirical data to evaluate the bias and precision of raw species counts, the limiting forms of jackknife and Chao estimators, and multi-species occupancy models when estimating species richness to evaluate whether the choice of estimator can affect inferences about the relationships between environmental conditions and community size under variable detection processes. Four simulated scenarios with realistic and variable detection processes were considered. Results of simulations indicated that (1) raw species counts were always biased low, (2) single-visit jackknife and Chao estimators were significantly biased regardless of detection process, (3) multispecies occupancy models were more precise and generally less biased than the jackknife and Chao estimators, and (4) spatial heterogeneity resulting from the effects of a site covariate on species detection probabilities had significant impacts on the inferred relationships between species richness and a spatially explicit environmental condition. For a real dataset of bird observations in northwestern Alaska, the four estimation methods produced different estimates of local species richness, which severely affected inferences about the effects of shrubs on local avian richness. Overall, our results

  20. Diagnostic accuracy of (18F-FDG PET/CT for the detection of peritoneal carcinomatosis of colorectal origins

    Directory of Open Access Journals (Sweden)

    Bullier E

    2013-03-01

    Full Text Available Purpose: to evaluate the diagnostic accuracy of (18 F-FDG positron emission tomography/ computerized tomography (PET/CT for the detection of peritoneal carcinomatosis (PC of colorectal cancer (CRC. Methods: one hundred and forty six eligible patients referred for a PET/CT to evaluate CRC at a single institution were included consecutively and retrospectively. After joint training on 20 similar patient files, two nuclear physicians reviewed the PET/CT scans blindly and independently using a method specifically designed for PC detection. The gold standard was either histological results from surgical exploration for resected patients (n=65 or clinical follow up defined as the 3-month CT follow up supplemented by one year of clinical information and CT monitoring for non-resected patients (n=81. As secondary objectives we evaluated the interobserver reliability between the two PET/CT readings and the diagnostic accuracy of a contemporary ceCT (n=69 or CT component of the PET/CT (n=77 reviewed by an independent radiologist . The extent of PC according to a simplified Sugarbaker index (PCI was examined for the operated subgroup, when PCI was available from the surgeon and PET/CT (n=12. Results: according to the gold standard, 35/146 patients had PC (including 19 of 65 patients with histological gold standard and 16 of 81 patients with clinical follow up gold standard. Sensitivity and specificity of PET/CT were 88% and 96% respectively and positive and negative predictive values and accuracy, 88%, 96% and 94% respectively. For CT alone, the corresponding values were: 68%, 92%, 72%, 90% and 86%. The interobserver agreement for the detection of peritoneal carcinomatosis in PET/CT showed high agreement at 0.91 (Kappa. Median PCI was 3 [range: 1–13] when assessed by surgeons and 4 [range: 1–10] on PET/CT. Focal uptake was the most frequently observed sign on PET. Conclusions: PET/CT appears to be an accurate and reproducible test for PC diagnosis in

  1. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  2. High-accuracy detection of early Parkinson's Disease using multiple characteristics of finger movement while typing.

    Directory of Open Access Journals (Sweden)

    Warwick R Adams

    Full Text Available Parkinson's Disease (PD is a progressive neurodegenerative movement disease affecting over 6 million people worldwide. Loss of dopamine-producing neurons results in a range of both motor and non-motor symptoms, however there is currently no definitive test for PD by non-specialist clinicians, especially in the early disease stages where the symptoms may be subtle and poorly characterised. This results in a high misdiagnosis rate (up to 25% by non-specialists and people can have the disease for many years before diagnosis. There is a need for a more accurate, objective means of early detection, ideally one which can be used by individuals in their home setting. In this investigation, keystroke timing information from 103 subjects (comprising 32 with mild PD severity and the remainder non-PD controls was captured as they typed on a computer keyboard over an extended period and showed that PD affects various characteristics of hand and finger movement and that these can be detected. A novel methodology was used to classify the subjects' disease status, by utilising a combination of many keystroke features which were analysed by an ensemble of machine learning classification models. When applied to two separate participant groups, this approach was able to successfully discriminate between early-PD subjects and controls with 96% sensitivity, 97% specificity and an AUC of 0.98. The technique does not require any specialised equipment or medical supervision, and does not rely on the experience and skill of the practitioner. Regarding more general application, it currently does not incorporate a second cardinal disease symptom, so may not differentiate PD from similar movement-related disorders.

  3. Predicting detection performance with model observers: Fourier domain or spatial domain?

    Science.gov (United States)

    Chen, Baiyu; Yu, Lifeng; Leng, Shuai; Kofler, James; Favazza, Christopher; Vrieze, Thomas; McCollough, Cynthia

    2016-02-27

    The use of Fourier domain model observer is challenged by iterative reconstruction (IR), because IR algorithms are nonlinear and IR images have noise texture different from that of FBP. A modified Fourier domain model observer, which incorporates nonlinear noise and resolution properties, has been proposed for IR and needs to be validated with human detection performance. On the other hand, the spatial domain model observer is theoretically applicable to IR, but more computationally intensive than the Fourier domain method. The purpose of this study is to compare the modified Fourier domain model observer to the spatial domain model observer with both FBP and IR images, using human detection performance as the gold standard. A phantom with inserts of various low contrast levels and sizes was repeatedly scanned 100 times on a third-generation, dual-source CT scanner at 5 dose levels and reconstructed using FBP and IR algorithms. The human detection performance of the inserts was measured via a 2-alternative-forced-choice (2AFC) test. In addition, two model observer performances were calculated, including a Fourier domain non-prewhitening model observer and a spatial domain channelized Hotelling observer. The performance of these two mode observers was compared in terms of how well they correlated with human observer performance. Our results demonstrated that the spatial domain model observer correlated well with human observers across various dose levels, object contrast levels, and object sizes. The Fourier domain observer correlated well with human observers using FBP images, but overestimated the detection performance using IR images.

  4. Spatial-Spectral Approaches to Edge Detection in Hyperspectral Remote Sensing

    Science.gov (United States)

    Cox, Cary M.

    This dissertation advances geoinformation science at the intersection of hyperspectral remote sensing and edge detection methods. A relatively new phenomenology among its remote sensing peers, hyperspectral imagery (HSI) comprises only about 7% of all remote sensing research - there are five times as many radar-focused peer reviewed journal articles than hyperspectral-focused peer reviewed journal articles. Similarly, edge detection studies comprise only about 8% of image processing research, most of which is dedicated to image processing techniques most closely associated with end results, such as image classification and feature extraction. Given the centrality of edge detection to mapping, that most important of geographic functions, improving the collective understanding of hyperspectral imagery edge detection methods constitutes a research objective aligned to the heart of geoinformation sciences. Consequently, this dissertation endeavors to narrow the HSI edge detection research gap by advancing three HSI edge detection methods designed to leverage HSI's unique chemical identification capabilities in pursuit of generating accurate, high-quality edge planes. The Di Zenzo-based gradient edge detection algorithm, an innovative version of the Resmini HySPADE edge detection algorithm and a level set-based edge detection algorithm are tested against 15 traditional and non-traditional HSI datasets spanning a range of HSI data configurations, spectral resolutions, spatial resolutions, bandpasses and applications. This study empirically measures algorithm performance against Dr. John Canny's six criteria for a good edge operator: false positives, false negatives, localization, single-point response, robustness to noise and unbroken edges. The end state is a suite of spatial-spectral edge detection algorithms that produce satisfactory edge results against a range of hyperspectral data types applicable to a diverse set of earth remote sensing applications. This work

  5. A Spatially Offset Raman Spectroscopy Method for Non-Destructive Detection of Gelatin-Encapsulated Powders

    Directory of Open Access Journals (Sweden)

    Kuanglin Chao

    2017-03-01

    Full Text Available Non-destructive subsurface detection of encapsulated, coated, or seal-packaged foods and pharmaceuticals can help prevent distribution and consumption of counterfeit or hazardous products. This study used a Spatially Offset Raman Spectroscopy (SORS method to detect and identify urea, ibuprofen, and acetaminophen powders contained within one or more (up to eight layers of gelatin capsules to demonstrate subsurface chemical detection and identification. A 785-nm point-scan Raman spectroscopy system was used to acquire spatially offset Raman spectra for an offset range of 0 to 10 mm from the surfaces of 24 encapsulated samples, using a step size of 0.1 mm to obtain 101 spectral measurements per sample. As the offset distance was increased, the spectral contribution from the subsurface powder gradually outweighed that of the surface capsule layers, allowing for detection of the encapsulated powders. Containing mixed contributions from the powder and capsule, the SORS spectra for each sample were resolved into pure component spectra using self-modeling mixture analysis (SMA and the corresponding components were identified using spectral information divergence values. As demonstrated here for detecting chemicals contained inside thick capsule layers, this SORS measurement technique coupled with SMA has the potential to be a reliable non-destructive method for subsurface inspection and authentication of foods, health supplements, and pharmaceutical products that are prepared or packaged with semi-transparent materials.

  6. The reliability, accuracy and minimal detectable difference of a multi-segment kinematic model of the foot-shoe complex.

    Science.gov (United States)

    Bishop, Chris; Paul, Gunther; Thewlis, Dominic

    2013-04-01

    Kinematic models are commonly used to quantify foot and ankle kinematics, yet no marker sets or models have been proven reliable or accurate when wearing shoes. Further, the minimal detectable difference of a developed model is often not reported. We present a kinematic model that is reliable, accurate and sensitive to describe the kinematics of the foot-shoe complex and lower leg during walking gait. In order to achieve this, a new marker set was established, consisting of 25 markers applied on the shoe and skin surface, which informed a four segment kinematic model of the foot-shoe complex and lower leg. Three independent experiments were conducted to determine the reliability, accuracy and minimal detectable difference of the marker set and model. Inter-rater reliability of marker placement on the shoe was proven to be good to excellent (ICC=0.75-0.98) indicating that markers could be applied reliably between raters. Intra-rater reliability was better for the experienced rater (ICC=0.68-0.99) than the inexperienced rater (ICC=0.38-0.97). The accuracy of marker placement along each axis was <6.7 mm for all markers studied. Minimal detectable difference (MDD90) thresholds were defined for each joint; tibiocalcaneal joint--MDD90=2.17-9.36°, tarsometatarsal joint--MDD90=1.03-9.29° and the metatarsophalangeal joint--MDD90=1.75-9.12°. These thresholds proposed are specific for the description of shod motion, and can be used in future research designed at comparing between different footwear. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Accuracy of Digital Radiography and Cone Beam Computed Tomography on Periapical Radiolucency Detection in Endodontically Treated Teeth

    Directory of Open Access Journals (Sweden)

    Tadas Venskutonis

    2014-07-01

    Full Text Available Objectives: The aim of the present study was to compare the accuracy of intraoral digital periapical radiography and cone beam computed tomography in the detection of periapical radiolucencies in endodontically treated teeth. Material and Methods: Radiographic images (cone beam computed tomography [CBCT] scans and digital periapical radiography [PR] images from 60 patients, achieved from September 2008 to July 2013, were retrieved from databases of the Department of Oral Diseases, Lithuanian University of Health Sciences. Twenty patients met inclusion criteria and were selected for further evaluation. Results: In 20 patients (42.4 [SD 12.1] years, 65% men and 35% women a total of 35 endodontically treated teeth (1.75 [SD 0.91]; 27 in maxilla and 8 in mandible were evaluated. Overall, it was observed a statistical significant difference between the number of periapical lesions observed in the CBCT (n = 42 and radiographic (n = 24 examinations (P < 0.05. In molar teeth, CBCT identify a significantly higher amount of periapical lesions than with the radiographic method (P < 0.05. There were significant differences between CBCT and PR in the mean number of lesions identified per tooth (1.2 vs 0.66, P = 0.03, number of teeth with lesions (0.71 vs 0.46, P = 0.03 and number of lesions identified per canal (0.57 vs 0.33, P = 0.005. Considering CBCT as “gold standard” in lesion detection with the sensitivity, specificity and accuracy considering as score 1, then the same parameters of PR were 0.57, 1 and 0.76 respectively. Conclusions: Within the limitations of the present study, it can be concluded that cone beam computed tomography scans were more accurate compared to digital periapical radiographs for detecting periapical radiolucencies in endodontically treated teeth. The difference was more pronounced in molar teeth.

  8. Is early detection of abused children possible?: a systematic review of the diagnostic accuracy of the identification of abused children

    Science.gov (United States)

    2013-01-01

    Background Early detection of abused children could help decrease mortality and morbidity related to this major public health problem. Several authors have proposed tools to screen for child maltreatment. The aim of this systematic review was to examine the evidence on accuracy of tools proposed to identify abused children before their death and assess if any were adapted to screening. Methods We searched in PUBMED, PsycINFO, SCOPUS, FRANCIS and PASCAL for studies estimating diagnostic accuracy of tools identifying neglect, or physical, psychological or sexual abuse of children, published in English or French from 1961 to April 2012. We extracted selected information about study design, patient populations, assessment methods, and the accuracy parameters. Study quality was assessed using QUADAS criteria. Results A total of 2 280 articles were identified. Thirteen studies were selected, of which seven dealt with physical abuse, four with sexual abuse, one with emotional abuse, and one with any abuse and physical neglect. Study quality was low, even when not considering the lack of gold standard for detection of abused children. In 11 studies, instruments identified abused children only when they had clinical symptoms. Sensitivity of tests varied between 0.26 (95% confidence interval [0.17-0.36]) and 0.97 [0.84-1], and specificity between 0.51 [0.39-0.63] and 1 [0.95-1]. The sensitivity was greater than 90% only for three tests: the absence of scalp swelling to identify children victims of inflicted head injury; a decision tool to identify physically-abused children among those hospitalized in a Pediatric Intensive Care Unit; and a parental interview integrating twelve child symptoms to identify sexually-abused children. When the sensitivity was high, the specificity was always smaller than 90%. Conclusions In 2012, there is low-quality evidence on the accuracy of instruments for identifying abused children. Identified tools were not adapted to screening because of

  9. Effect of absorbing impurities on the accuracy of the optical method for the detection of the iodine-containing substances resulting from the processing of waste nuclear fuel

    Science.gov (United States)

    Kireev, S. V.; Simanovsky, I. G.; Shnyrev, S. L.

    2010-12-01

    The study is aimed at an increase in the accuracy of the optical method for the detection of the iodine-containing substances in technological liquids resulting form the processing of the waste nuclear fuel. It is demonstrated that the accuracy can be increased owing to the measurements at various combinations of wavelengths depending on the concentrations of impurities that are contained in the sample under study and absorb in the spectral range used for the detection of the iodine-containing substances.

  10. Comparative accuracy of Computed Tomography and lymphoangiography in detecting lymph node metastases from epithelial cancer of the ovary

    International Nuclear Information System (INIS)

    La Fianza, A.; Dore, R.; Campani, R.; Babilonti, L.; Tateo, S.

    1991-01-01

    The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% positive predictive value, and 84.6% vs 81.5% negative predictive value. In the second group (clinically suspected relapse), CT accuracy, sensitivity and specificity were, respectively: 91.3%, 81.8%,and 100%. Our experience demonstrated a high incidence of lymph node metastases in ovarian cancer, both in pelvic (15/49; 25.5%) and especially in aortic (15/37; 40.5%) locations in untreated patients, and an even higher incidence in relapses (22/42; 52.5%). The high specificity and positive predictive value of CT depended on the fact that there were no false positives. We arbitrarily considered as metastatic a lymph node with diameter >2cm, and this threshold seemed to be of clinical value since it made a good predictor of metastases. Among diagnostic imaging modalities, CT is suggested as the method of choice for the evaluation of pelvic and paraaortic lymph node metastases in untreated and relapsing ovarian cancers. Lymphangiography, a more invasive- though more accurate- technique, is indicated after normal CT

  11. Development of a geometric uncertainty model describing the accuracy of position-sensitive, coincidence neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Trivelpiece, Cory L., E-mail: cory@psu.ed [Department of Mechanical and Nuclear Engineering, The Pennsylvania, State University, University Park, PA 16802 (United States); Brenizer, J.S. [Department of Mechanical and Nuclear Engineering, The Pennsylvania, State University, University Park, PA 16802 (United States)

    2011-01-01

    A diameter of uncertainty (D{sub u}) was derived from a geometric uncertainty model describing the error that would be introduced into position-sensitive, coincidence neutron detection measurements by charged-particle transport phenomena and experimental setup. The transport of {alpha} and Li ions, produced by the {sup 10}B(n,{alpha}) {sup 7}Li reaction, through free-standing boro-phosphosilicate glass (BPSG) films was modeled using the Monte Carlo code SRIM, and the results of these simulations were used as input to determine D{sub u} for position-sensitive, coincidence techniques. The results of these calculations showed that D{sub u} is dependent on encoder separation, the angle of charged particle emission, and film thickness. For certain emission scenarios, the magnitude of D{sub u} is larger than the physical size of the neutron converting media that were being modeled. Spheres of uncertainty were developed that describe the difference in flight path times among the bounding-case emission scenarios that were considered in this work. It was shown the overlapping spheres represent emission angles and particle flight path lengths that would be difficult to resolve in terms of particle time-of-flight measurements. However, based on the timing resolution of current nuclear instrumentation, emission events that yield large D{sub u} can be discriminated by logical arguments during spectral deconvolution.

  12. Accuracy of an automated system for tuberculosis detection on chest radiographs in high-risk screening.

    Science.gov (United States)

    Melendez, J; Hogeweg, L; Sánchez, C I; Philipsen, R H H M; Aldridge, R W; Hayward, A C; Abubakar, I; van Ginneken, B; Story, A

    2018-05-01

    Tuberculosis (TB) screening programmes can be optimised by reducing the number of chest radiographs (CXRs) requiring interpretation by human experts. To evaluate the performance of computerised detection software in triaging CXRs in a high-throughput digital mobile TB screening programme. A retrospective evaluation of the software was performed on a database of 38 961 postero-anterior CXRs from unique individuals seen between 2005 and 2010, 87 of whom were diagnosed with TB. The software generated a TB likelihood score for each CXR. This score was compared with a reference standard for notified active pulmonary TB using receiver operating characteristic (ROC) curve and localisation ROC (LROC) curve analyses. On ROC curve analysis, software specificity was 55.71% (95%CI 55.21-56.20) and negative predictive value was 99.98% (95%CI 99.95-99.99), at a sensitivity of 95%. The area under the ROC curve was 0.90 (95%CI 0.86-0.93). Results of the LROC curve analysis were similar. The software could identify more than half of the normal images in a TB screening setting while maintaining high sensitivity, and may therefore be used for triage.

  13. Detection of auditory signals in quiet and noisy backgrounds while performing a visuo-spatial task

    Directory of Open Access Journals (Sweden)

    Vishakha W Rawool

    2016-01-01

    Full Text Available Context: The ability to detect important auditory signals while performing visual tasks may be further compounded by background chatter. Thus, it is important to know how task performance may interact with background chatter to hinder signal detection. Aim: To examine any interactive effects of speech spectrum noise and task performance on the ability to detect signals. Settings and Design: The setting was a sound-treated booth. A repeated measures design was used. Materials and Methods: Auditory thresholds of 20 normal adults were determined at 0.5, 1, 2 and 4 kHz in the following conditions presented in a random order: (1 quiet with attention; (2 quiet with a visuo-spatial task or puzzle (distraction; (3 noise with attention and (4 noise with task. Statistical Analysis: Multivariate analyses of variance (MANOVA with three repeated factors (quiet versus noise, visuo-spatial task versus no task, signal frequency. Results: MANOVA revealed significant main effects for noise and signal frequency and significant noise–frequency and task–frequency interactions. Distraction caused by performing the task worsened the thresholds for tones presented at the beginning of the experiment and had no effect on tones presented in the middle. At the end of the experiment, thresholds (4 kHz were better while performing the task than those obtained without performing the task. These effects were similar across the quiet and noise conditions. Conclusion: Detection of auditory signals is difficult at the beginning of a distracting visuo-spatial task but over time, task learning and auditory training effects can nullify the effect of distraction and may improve detection of high frequency sounds.

  14. Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT.

    Science.gov (United States)

    Baltacıoĝlu, İsmail H; Eren, Hakan; Yavuz, Yasemin; Kamburoğlu, Kıvanç

    To assess the in vitro diagnostic ability of CBCT images using seven different display types in the detection of recurrent caries. Our study comprised 128 extracted human premolar and molar teeth. 8 groups each containing 16 teeth were obtained as follows: (1) Black Class I (Occlusal) amalgam filling without caries; (2) Black Class I (Occlusal) composite filling without caries; (3) Black Class II (Proximal) amalgam filling without caries; (4) Black Class II (Proximal) composite filling without caries; (5) Black Class I (Occlusal) amalgam filling with caries; (6) Black Class I (Occlusal) composite filling with caries; (7) Black Class II (Proximal) amalgam filling with caries; and (8) Black Class II (Proximal) composite filling with caries. Teeth were imaged using 100 × 90 mm field of view at three different voxel sizes of a CBCT unit (Planmeca ProMax(®) 3D ProFace™; Planmeca, Helsinki, Finland). CBCT TIFF images were opened and viewed using custom-designed software for computers on different display types. Intra- and interobserver agreements were calculated. The highest area under the receiver operating characteristic curve (Az) values for each image type, observer, reading and restoration were compared using z-tests against Az = 0.5. The significance level was set at p = 0.05. We found poor and moderate agreements. In general, Az values were found when software and medical diagnostic monitor were utilized. For Observer 2, Az values were statistically significantly higher when software was used on medical monitor [p = 0.036, p = 0.015 and p = 0.002, for normal-resolution mode (0.200 mm(3) voxel size), high-resolution mode (0.150 mm(3) voxel size) and low-resolution mode (0.400 mm(3) voxel size), respectively]. No statistically significant differences were found among other display types for all modes (p > 0.05). In general, no difference was found among 3 different voxel sizes (p > 0.05). In general, higher Az values were

  15. Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT

    Science.gov (United States)

    Baltacıoĝlu, İsmail H; Eren, Hakan; Yavuz, Yasemin

    2016-01-01

    Objectives: To assess the in vitro diagnostic ability of CBCT images using seven different display types in the detection of recurrent caries. Methods: Our study comprised 128 extracted human premolar and molar teeth. 8 groups each containing 16 teeth were obtained as follows: (1) Black Class I (Occlusal) amalgam filling without caries; (2) Black Class I (Occlusal) composite filling without caries; (3) Black Class II (Proximal) amalgam filling without caries; (4) Black Class II (Proximal) composite filling without caries; (5) Black Class I (Occlusal) amalgam filling with caries; (6) Black Class I (Occlusal) composite filling with caries; (7) Black Class II (Proximal) amalgam filling with caries; and (8) Black Class II (Proximal) composite filling with caries. Teeth were imaged using 100 × 90 mm field of view at three different voxel sizes of a CBCT unit (Planmeca ProMax® 3D ProFace™; Planmeca, Helsinki, Finland). CBCT TIFF images were opened and viewed using custom-designed software for computers on different display types. Intra- and interobserver agreements were calculated. The highest area under the receiver operating characteristic curve (Az) values for each image type, observer, reading and restoration were compared using z-tests against Az = 0.5. The significance level was set at p = 0.05. Results: We found poor and moderate agreements. In general, Az values were found when software and medical diagnostic monitor were utilized. For Observer 2, Az values were statistically significantly higher when software was used on medical monitor [p = 0.036, p = 0.015 and p = 0.002, for normal-resolution mode (0.200 mm3 voxel size), high-resolution mode (0.150 mm3 voxel size) and low-resolution mode (0.400 mm3 voxel size), respectively]. No statistically significant differences were found among other display types for all modes (p > 0.05). In general, no difference was found among 3 different voxel sizes (p > 0.05). In general

  16. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  17. A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging

    International Nuclear Information System (INIS)

    Gong Xing; Glick, Stephen J.; Liu, Bob; Vedula, Aruna A.; Thacker, Samta

    2006-01-01

    Although conventional mammography is currently the best modality to detect early breast cancer, it is limited in that the recorded image represents the superposition of a three-dimensional (3D) object onto a 2D plane. Recently, two promising approaches for 3D volumetric breast imaging have been proposed, breast tomosynthesis (BT) and CT breast imaging (CTBI). To investigate possible improvements in lesion detection accuracy with either breast tomosynthesis or CT breast imaging as compared to digital mammography (DM), a computer simulation study was conducted using simulated lesions embedded into a structured 3D breast model. The computer simulation realistically modeled x-ray transport through a breast model, as well as the signal and noise propagation through a CsI based flat-panel imager. Polyenergetic x-ray spectra of Mo/Mo 28 kVp for digital mammography, Mo/Rh 28 kVp for BT, and W/Ce 50 kVp for CTBI were modeled. For the CTBI simulation, the intensity of the x-ray spectra for each projection view was determined so as to provide a total average glandular dose of 4 mGy, which is approximately equivalent to that given in conventional two-view screening mammography. The same total dose was modeled for both the DM and BT simulations. Irregular lesions were simulated by using a stochastic growth algorithm providing lesions with an effective diameter of 5 mm. Breast tissue was simulated by generating an ensemble of backgrounds with a power law spectrum, with the composition of 50% fibroglandular and 50% adipose tissue. To evaluate lesion detection accuracy, a receiver operating characteristic (ROC) study was performed with five observers reading an ensemble of images for each case. The average area under the ROC curves (A z ) was 0.76 for DM, 0.93 for BT, and 0.94 for CTBI. Results indicated that for the same dose, a 5 mm lesion embedded in a structured breast phantom was detected by the two volumetric breast imaging systems, BT and CTBI, with statistically

  18. Accuracy of methods for detecting an irregular pulse and suspected atrial fibrillation: A systematic review and meta-analysis.

    Science.gov (United States)

    Taggar, Jaspal S; Coleman, Tim; Lewis, Sarah; Heneghan, Carl; Jones, Matthew

    2016-08-01

    Pulse palpation has been recommended as the first step of screening to detect atrial fibrillation. We aimed to determine and compare the accuracy of different methods for detecting pulse irregularities caused by atrial fibrillation. We systematically searched MEDLINE, EMBASE, CINAHL and LILACS until 16 March 2015. Two reviewers identified eligible studies, extracted data and appraised quality using the QUADAS-2 instrument. Meta-analysis, using the bivariate hierarchical random effects method, determined average operating points for sensitivities, specificities, positive and negative likelihood ratios (PLR, NLR); we constructed summary receiver operating characteristic plots. Twenty-one studies investigated 39 interventions (n = 15,129 pulse assessments) for detecting atrial fibrillation. Compared to 12-lead electrocardiography (ECG) diagnosed atrial fibrillation, blood pressure monitors (BPMs; seven interventions) and non-12-lead ECGs (20 interventions) had the greatest accuracy for detecting pulse irregularities attributable to atrial fibrillation (BPM: sensitivity 0.98 (95% confidence interval (CI) 0.92-1.00), specificity 0.92 (95% CI 0.88-0.95), PLR 12.1 (95% CI 8.2-17.8) and NLR 0.02 (95% CI 0.00-0.09); non-12-lead ECG: sensitivity 0.91 (95% CI 0.86-0.94), specificity 0.95 (95% CI 0.92-0.97), PLR 20.1 (95% CI 12-33.7), NLR 0.09 (95% CI 0.06-0.14)). There were similar findings for smartphone applications (six interventions) although these studies were small in size. The sensitivity and specificity of pulse palpation (six interventions) were 0.92 (95% CI 0.85-0.96) and 0.82 (95% CI 0.76-0.88), respectively (PLR 5.2 (95% CI 3.8-7.2), NLR 0.1 (95% CI 0.05-0.18)). BPMs and non-12-lead ECG were most accurate for detecting pulse irregularities caused by atrial fibrillation; other technologies may therefore be pragmatic alternatives to pulse palpation for the first step of atrial fibrillation screening. © The European Society of Cardiology 2015.

  19. Accuracy and precision of equine gait event detection during walking with limb and trunk mounted inertial sensors

    DEFF Research Database (Denmark)

    Olsen, Emil; Andersen, Pia Haubro; Pfau, Thilo

    2012-01-01

    The increased variations of temporal gait events when pathology is present are good candidate features for objective diagnostic tests. We hypothesised that the gait events hoof-on/off and stance can be detected accurately and precisely using features from trunk and distal limb-mounted Inertial....... Accuracy (bias) and precision (SD of bias) was calculated to compare force plate and IMU timings for gait events. Data were collected from seven horses. One hundred and twenty three (123) front limb steps were analysed; hoof-on was detected with a bias (SD) of -7 (23) ms, hoof-off with 0.7 (37) ms...... and front limb stance with -0.02 (37) ms. A total of 119 hind limb steps were analysed; hoof-on was found with a bias (SD) of -4 (25) ms, hoof-off with 6 (21) ms and hind limb stance with 0.2 (28) ms. IMUs mounted on the distal limbs and sacrum can detect gait events accurately and precisely....

  20. Detecting Temporal and Spatial Effects of Epithelial Cancers with Raman Spectroscopy

    Directory of Open Access Journals (Sweden)

    Matthew D. Keller

    2008-01-01

    Full Text Available Epithelial cancers, including those of the skin and cervix, are the most common type of cancers in humans. Many recent studies have attempted to use Raman spectroscopy to diagnose these cancers. In this paper, Raman spectral markers related to the temporal and spatial effects of cervical and skin cancers are examined through four separate but related studies. Results from a clinical cervix study show that previous disease has a significant effect on the Raman signatures of the cervix, which allow for near 100% classification for discriminating previous disease versus a true normal. A Raman microspectroscopy study showed that Raman can detect changes due to adjacent regions of dysplasia or HPV that cannot be detected histologically, while a clinical skin study showed that Raman spectra may be detecting malignancy associated changes in tissues surrounding nonmelanoma skin cancers. Finally, results of an organotypic raft culture study provided support for both the skin and the in vitro cervix results. These studies add to the growing body of evidence that optical spectroscopy, in this case Raman spectral markers, can be used to detect subtle temporal and spatial effects in tissue near cancerous sites that go otherwise undetected by conventional histology.

  1. An evaluation of the subtraction photoshop software accuracy to detect minor changes in optical density by radiovisiography

    Directory of Open Access Journals (Sweden)

    Talaeipour AR.

    2004-06-01

    Full Text Available Statement of Problem: Subtraction is a newly presented radiography technique to detect minor density"nchanges that are not visible by conventional radiography."nPurpose: The aim of this In-vitro study was to evaluate the efficacy of photoshop subtraction software for"ndetecting minor density changes between two dental images."nMaterials and Methods: In this research, five dried human mandibles were held in fixed position while thin"naluminium sheets were superimposed on each mandible on the 1th and 2nd molar teeth regions."nA reference image, without aluminium sheet placement, was obtained from each mandible subsequently series"nconsist of 20 images with aluminium sheets, ranging from 50p. to "5Q0"x were recorded by radiovisiography"n(RVG system. Initial images were subtracted from subsequent ones by Photoshop subtraction software. The"ndifference in density between the two images at the 1st and 2nd molar sites was related to the aluminium"nsheets. The optical density of aluminium sheets was determined by densitometer."nResults: In the present study, 6.6% of the optical density changes of the minimum aluminium thickness as"n300u. could be detected by photoshop software software."nConclusion: The findings of this study showed that the accuracy of photoshop subtraction software was equal"nto that of the conventional subtraction softwares. Additionally, the accuracy of this software was proved to be"nsuitable for clinical investigations of small localized changes in alveolar bone.

  2. Diagnostic Accuracy of a New Cardiac Electrical Biomarker for Detection of Electrocardiogram Changes Suggestive of Acute Myocardial Ischemic Injury

    Science.gov (United States)

    Schreck, David M; Fishberg, Robert D

    2014-01-01

    Objective A new cardiac “electrical” biomarker (CEB) for detection of 12-lead electrocardiogram (ECG) changes indicative of acute myocardial ischemic injury has been identified. Objective was to test CEB diagnostic accuracy. Methods This is a blinded, observational retrospective case-control, noninferiority study. A total of 508 ECGs obtained from archived digital databases were interpreted by cardiologist and emergency physician (EP) blinded reference standards for presence of acute myocardial ischemic injury. CEB was constructed from three ECG cardiac monitoring leads using nonlinear modeling. Comparative active controls included ST voltage changes (J-point, ST area under curve) and a computerized ECG interpretive algorithm (ECGI). Training set of 141 ECGs identified CEB cutoffs by receiver-operating-characteristic (ROC) analysis. Test set of 367 ECGs was analyzed for validation. Poor-quality ECGs were excluded. Sensitivity, specificity, and negative and positive predictive values were calculated with 95% confidence intervals. Adjudication was performed by consensus. Results CEB demonstrated noninferiority to all active controls by hypothesis testing. CEB adjudication demonstrated 85.3–94.4% sensitivity, 92.5–93.0% specificity, 93.8–98.6% negative predictive value, and 74.6–83.5% positive predictive value. CEB was superior against all active controls in EP analysis, and against ST area under curve and ECGI by cardiologist. Conclusion CEB detects acute myocardial ischemic injury with high diagnostic accuracy. CEB is instantly constructed from three ECG leads on the cardiac monitor and displayed instantly allowing immediate cost-effective identification of patients with acute ischemic injury during cardiac rhythm monitoring. PMID:24118724

  3. Uncertainty of a detected spatial cluster in 1D: quantification and visualization

    KAUST Repository

    Lee, Junho; Gangnon, Ronald E.; Zhu, Jun; Liang, Jingjing

    2017-01-01

    Spatial cluster detection is an important problem in a variety of scientific disciplines such as environmental sciences, epidemiology and sociology. However, there appears to be very limited statistical methodology for quantifying the uncertainty of a detected cluster. In this paper, we develop a new method for the quantification and visualization of uncertainty associated with a detected cluster. Our approach is defining a confidence set for the true cluster and visualizing the confidence set, based on the maximum likelihood, in time or in one-dimensional space. We evaluate the pivotal property of the statistic used to construct the confidence set and the coverage rate for the true cluster via empirical distributions. For illustration, our methodology is applied to both simulated data and an Alaska boreal forest dataset. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Spatial-time-state fusion algorithm for defect detection through eddy current pulsed thermography

    Science.gov (United States)

    Xiao, Xiang; Gao, Bin; Woo, Wai Lok; Tian, Gui Yun; Xiao, Xiao Ting

    2018-05-01

    Eddy Current Pulsed Thermography (ECPT) has received extensive attention due to its high sensitive of detectability on surface and subsurface cracks. However, it remains as a difficult challenge in unsupervised detection as to identify defects without knowing any prior knowledge. This paper presents a spatial-time-state features fusion algorithm to obtain fully profile of the defects by directional scanning. The proposed method is intended to conduct features extraction by using independent component analysis (ICA) and automatic features selection embedding genetic algorithm. Finally, the optimal feature of each step is fused to obtain defects reconstruction by applying common orthogonal basis extraction (COBE) method. Experiments have been conducted to validate the study and verify the efficacy of the proposed method on blind defect detection.

  5. Uncertainty of a detected spatial cluster in 1D: quantification and visualization

    KAUST Repository

    Lee, Junho

    2017-10-19

    Spatial cluster detection is an important problem in a variety of scientific disciplines such as environmental sciences, epidemiology and sociology. However, there appears to be very limited statistical methodology for quantifying the uncertainty of a detected cluster. In this paper, we develop a new method for the quantification and visualization of uncertainty associated with a detected cluster. Our approach is defining a confidence set for the true cluster and visualizing the confidence set, based on the maximum likelihood, in time or in one-dimensional space. We evaluate the pivotal property of the statistic used to construct the confidence set and the coverage rate for the true cluster via empirical distributions. For illustration, our methodology is applied to both simulated data and an Alaska boreal forest dataset. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Spatial and temporal control of thermal waves by using DMDs for interference based crack detection

    Science.gov (United States)

    Thiel, Erik; Kreutzbruck, Marc; Ziegler, Mathias

    2016-02-01

    Active Thermography is a well-established non-destructive testing method and used to detect cracks, voids or material inhomogeneities. It is based on applying thermal energy to a samples' surface whereas inner defects alter the nonstationary heat flow. Conventional excitation of a sample is hereby done spatially, either planar (e.g. using a lamp) or local (e.g. using a focused laser) and temporally, either pulsed or periodical. In this work we combine a high power laser with a Digital Micromirror Device (DMD) allowing us to merge all degrees of freedom to a spatially and temporally controlled heat source. This enables us to exploit the possibilities of coherent thermal wave shaping. Exciting periodically while controlling at the same time phase and amplitude of the illumination source induces - via absorption at the sample's surface - a defined thermal wave propagation through a sample. That means thermal waves can be controlled almost like acoustical or optical waves. However, in contrast to optical or acoustical waves, thermal waves are highly damped due to the diffusive character of the thermal heat flow and therefore limited in penetration depth in relation to the achievable resolution. Nevertheless, the coherence length of thermal waves can be chosen in the mmrange for modulation frequencies below 10 Hz which is perfectly met by DMD technology. This approach gives us the opportunity to transfer known technologies from wave shaping techniques to thermography methods. We will present experiments on spatial and temporal wave shaping, demonstrating interference based crack detection.

  7. Detection of the power lines in UAV remote sensed images using spectral-spatial methods.

    Science.gov (United States)

    Bhola, Rishav; Krishna, Nandigam Hari; Ramesh, K N; Senthilnath, J; Anand, Gautham

    2018-01-15

    In this paper, detection of the power lines on images acquired by Unmanned Aerial Vehicle (UAV) based remote sensing is carried out using spectral-spatial methods. Spectral clustering was performed using Kmeans and Expectation Maximization (EM) algorithm to classify the pixels into the power lines and non-power lines. The spectral clustering methods used in this study are parametric in nature, to automate the number of clusters Davies-Bouldin index (DBI) is used. The UAV remote sensed image is clustered into the number of clusters determined by DBI. The k clustered image is merged into 2 clusters (power lines and non-power lines). Further, spatial segmentation was performed using morphological and geometric operations, to eliminate the non-power line regions. In this study, UAV images acquired at different altitudes and angles were analyzed to validate the robustness of the proposed method. It was observed that the EM with spatial segmentation (EM-Seg) performed better than the Kmeans with spatial segmentation (Kmeans-Seg) on most of the UAV images. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Diagnostic accuracy of bone metastases detection in cancer patients. Comparison between bone scintigraphy and whole-body FDG-PET

    International Nuclear Information System (INIS)

    Fujimoto, Ryota; Higashi, Tatsuya; Nakamoto, Yuji

    2006-01-01

    18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) has become widely available and an important oncological technique. To evaluate the influence of PET on detection of bone metastasis, we compared the diagnostic accuracy of PET and conventional bone scintigraphy (BS) in a variety of cancer patients. Consecutive ninety-five patients with various cancers, who received both PET and BS within one month, were retrospectively analyzed. A whole-body PET (from face to upper thigh) and a standard whole body BS were performed and these images were interpreted by two experienced nuclear medicine physicians with and without patient information using monitor diagnosis. Each image interpretation was performed according to 8 separate areas (skull, vertebra, upper limbs, sternum and clavicles, scapula, ribs, pelvis, and lower limbs) using a 5-point-scale (0: definitely negative, 1: probably negative, 2: equivocal, 3: probably positive, 4: definitely positive for bone metastasis). Twenty-one of 95 patients (22.1%) with 43 of 760 areas (5.7%) of bone metastases were finally confirmed. In untreated patients, 12 of 14 bone metastasis positive patients were detected by PET, while 9 of 14 were detected by BS. Three cases showed true positive in PET and false negative in BS due to osteolytic type bone metastases. In untreated cases, PET with and without clinical information showed better sensitivity than BS in patient-based diagnosis. For the purpose of treatment effect evaluation, PET showed better results because of its ability in the evaluation of rapid response of tumor cells to chemotherapy. Out of 10 cases of multiple-area metastases, 9 cases included vertebrae. There was only one solitary lesion located outside of field of view (FOV) of PET scan in the femur, but with clinical information that was no problem for PET diagnosis. Diagnostic accuracy of bone metastasis was comparable in PET and BS in the present study. In a usual clinical condition, limited FOV (from

  9. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    Science.gov (United States)

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally

  10. Relative accuracy of spatial predictive models for lynx Lynx canadensis derived using logistic regression-AIC, multiple criteria evaluation and Bayesian approaches

    Directory of Open Access Journals (Sweden)

    Shelley M. ALEXANDER

    2009-02-01

    Full Text Available We compared probability surfaces derived using one set of environmental variables in three Geographic Information Systems (GIS-based approaches: logistic regression and Akaike’s Information Criterion (AIC, Multiple Criteria Evaluation (MCE, and Bayesian Analysis (specifically Dempster-Shafer theory. We used lynx Lynx canadensis as our focal species, and developed our environment relationship model using track data collected in Banff National Park, Alberta, Canada, during winters from 1997 to 2000. The accuracy of the three spatial models were compared using a contingency table method. We determined the percentage of cases in which both presence and absence points were correctly classified (overall accuracy, the failure to predict a species where it occurred (omission error and the prediction of presence where there was absence (commission error. Our overall accuracy showed the logistic regression approach was the most accurate (74.51%. The multiple criteria evaluation was intermediate (39.22%, while the Dempster-Shafer (D-S theory model was the poorest (29.90%. However, omission and commission error tell us a different story: logistic regression had the lowest commission error, while D-S theory produced the lowest omission error. Our results provide evidence that habitat modellers should evaluate all three error measures when ascribing confidence in their model. We suggest that for our study area at least, the logistic regression model is optimal. However, where sample size is small or the species is very rare, it may also be useful to explore and/or use a more ecologically cautious modelling approach (e.g. Dempster-Shafer that would over-predict, protect more sites, and thereby minimize the risk of missing critical habitat in conservation plans[Current Zoology 55(1: 28 – 40, 2009].

  11. Accuracy of detection of carboxyhemoglobin and methemoglobin in human and bovine blood with an inexpensive, pocket-size infrared scanner.

    Science.gov (United States)

    Bickler, Margot P; Rhodes, Laura J

    2018-01-01

    Detecting life-threatening common dyshemoglobins such as carboxyhemoglobin (COHb, resulting from carbon monoxide poisoning) or methemoglobin (MetHb, caused by exposure to nitrates) typically requires a laboratory CO-oximeter. Because of cost, these spectrophotometer-based instrument are often inaccessible in resource-poor settings. The aim of this study was to determine if an inexpensive pocket infrared spectrometer and smartphone (SCiO®Pocket Molecular Sensor, Consumer Physics Ltd., Israel) accurately detects COHb and MetHb in single drops of blood. COHb was created by adding carbon monoxide gas to syringes of heparinized blood human or cow blood. In separate syringes, MetHb was produced by addition of sodium nitrite solution. After incubation and mixing, fractional concentrations of COHb or MetHb were measured using a Radiometer ABL-90 Flex® CO-oximeter. Fifty microliters of the sample were then placed on a microscope slide, a cover slip applied and scanned with the SCiO spectrometer. The spectrograms were used to create simple linear models predicting [COHb] or [MetHb] based on spectrogram maxima, minima and isobestic wavelengths. Our model predicted clinically significant carbon monoxide poisoning (COHb ≥15%) with a sensitivity of 93% and specificity of 88% (regression r2 = 0.63, slope P20% MetHb) was detected with a sensitivity of 100% and specificity of 71% (regression r2 = 0.92, slope Psmartphone detects >15% COHb or >20% MetHb on a single drop of blood with enough accuracy to be useful as an initial clinical screening. The SCiO and similar relatively low cost spectrometers could be developed as inexpensive diagnostic tools for developing countries.

  12. Dim small targets detection based on self-adaptive caliber temporal-spatial filtering

    Science.gov (United States)

    Fan, Xiangsuo; Xu, Zhiyong; Zhang, Jianlin; Huang, Yongmei; Peng, Zhenming

    2017-09-01

    To boost the detect ability of dim small targets, this paper began by using improved anisotropy for background prediction (IABP), followed by target enhancement by improved high-order cumulates (HQS). Finally, on the basis of image pre-processing, to address the problem of missed and wrong detection caused by fixed caliber of traditional pipeline filtering, this paper used targets' multi-frame movement correlation in the time-space domain, combined with the scale-space theory, to propose a temporal-spatial filtering algorithm which allows the caliber to make self-adaptive changes according to the changes of the targets' scale, effectively solving the detection-related issues brought by unchanged caliber and decreased/increased size of the targets. Experiments showed that the improved anisotropic background predication could be loyal to the true background of the original image to the maximum extent, presenting a superior overall performance to other background prediction methods; the improved HQS significantly increased the signal-noise ratio of images; when the signal-noise ratio was lower than 2.6 dB, this detection algorithm could effectively eliminate noise and detect targets. For the algorithm, the lowest signal-to-noise ratio of the detectable target is 0.37.

  13. Analysis of laser-printed spatial resolution for mammographic microcalcification detection

    International Nuclear Information System (INIS)

    Smathers, R.L.; Kowarski, D.

    1987-01-01

    The detectability of microcalfications in mammograms was compared in Kodak Min-R screen-film mammograms versus digitized laser-printed films. Pulverized bone specks were used as the phantoms to produce the original mammograms. The mammograms were then digitized to a spatial resolution of 2,048 x, 2048 with 4,096 gray levels and laser-printed at spatial resolutions of 512 x 512, 1,024 x 1,024, and 2,048 x 2,048 with 256 gray levels. The number of bone specks was determined on a region-by region basis. The 512 x 512 resolution laser-printed images were nondiagnostic, 1,024 x 1,024 images were better, and 2,048 x 2,048 images were quite comparable to the original screen-film mammograms

  14. Spatial-temporal features of thermal images for Carpal Tunnel Syndrome detection

    Science.gov (United States)

    Estupinan Roldan, Kevin; Ortega Piedrahita, Marco A.; Benitez, Hernan D.

    2014-02-01

    Disorders associated with repeated trauma account for about 60% of all occupational illnesses, Carpal Tunnel Syndrome (CTS) being the most consulted today. Infrared Thermography (IT) has come to play an important role in the field of medicine. IT is non-invasive and detects diseases based on measuring temperature variations. IT represents a possible alternative to prevalent methods for diagnosis of CTS (i.e. nerve conduction studies and electromiography). This work presents a set of spatial-temporal features extracted from thermal images taken in healthy and ill patients. Support Vector Machine (SVM) classifiers test this feature space with Leave One Out (LOO) validation error. The results of the proposed approach show linear separability and lower validation errors when compared to features used in previous works that do not account for temperature spatial variability.

  15. Xpert MTB/RIF Ultra for detection of Mycobacterium tuberculosis and rifampicin resistance: a prospective multicentre diagnostic accuracy study.

    Science.gov (United States)

    Dorman, Susan E; Schumacher, Samuel G; Alland, David; Nabeta, Pamela; Armstrong, Derek T; King, Bonnie; Hall, Sandra L; Chakravorty, Soumitesh; Cirillo, Daniela M; Tukvadze, Nestani; Bablishvili, Nino; Stevens, Wendy; Scott, Lesley; Rodrigues, Camilla; Kazi, Mubin I; Joloba, Moses; Nakiyingi, Lydia; Nicol, Mark P; Ghebrekristos, Yonas; Anyango, Irene; Murithi, Wilfred; Dietze, Reynaldo; Lyrio Peres, Renata; Skrahina, Alena; Auchynka, Vera; Chopra, Kamal Kishore; Hanif, Mahmud; Liu, Xin; Yuan, Xing; Boehme, Catharina C; Ellner, Jerrold J; Denkinger, Claudia M

    2018-01-01

    The Xpert MTB/RIF assay is an automated molecular test that has improved the detection of tuberculosis and rifampicin resistance, but its sensitivity is inadequate in patients with paucibacillary disease or HIV. Xpert MTB/RIF Ultra (Xpert Ultra) was developed to overcome this limitation. We compared the diagnostic performance of Xpert Ultra with that of Xpert for detection of tuberculosis and rifampicin resistance. In this prospective, multicentre, diagnostic accuracy study, we recruited adults with pulmonary tuberculosis symptoms presenting at primary health-care centres and hospitals in eight countries (South Africa, Uganda, Kenya, India, China, Georgia, Belarus, and Brazil). Participants were allocated to the case detection group if no drugs had been taken for tuberculosis in the past 6 months or to the multidrug-resistance risk group if drugs for tuberculosis had been taken in the past 6 months, but drug resistance was suspected. Demographic information, medical history, chest imaging results, and HIV test results were recorded at enrolment, and each participant gave at least three sputum specimen on 2 separate days. Xpert and Xpert Ultra diagnostic performance in the same sputum specimen was compared with culture tests and drug susceptibility testing as reference standards. The primary objectives were to estimate and compare the sensitivity of Xpert Ultra test with that of Xpert for detection of smear-negative tuberculosis and rifampicin resistance and to estimate and compare Xpert Ultra and Xpert specificities for detection of rifampicin resistance. Study participants in the case detection group were included in all analyses, whereas participants in the multidrug-resistance risk group were only included in analyses of rifampicin-resistance detection. Between Feb 18, and Dec 24, 2016, we enrolled 2368 participants for sputum sampling. 248 participants were excluded from the analysis, and 1753 participants were distributed to the case detection group (n=1439

  16. Improved quantification accuracy for duplex real-time PCR detection of genetically modified soybean and maize in heat processed foods

    Directory of Open Access Journals (Sweden)

    CHENG Fang

    2013-04-01

    Full Text Available Real-time PCR technique has been widely used in quantitative GMO detection in recent years.The accuracy of GMOs quantification based on the real-time PCR methods is still a difficult problem,especially for the quantification of high processed samples.To develop the suitable and accurate real-time PCR system for high processed GM samples,we made ameliorations to several real-time PCR parameters,including re-designed shorter target DNA fragment,similar lengths of amplified endogenous and exogenous gene targets,similar GC contents and melting temperatures of PCR primers and TaqMan probes.Also,one Heat-Treatment Processing Model (HTPM was established using soybean flour samples containing GM soybean GTS 40-3-2 to validate the effectiveness of the improved real-time PCR system.Tested results showed that the quantitative bias of GM content in heat processed samples were lowered using the new PCR system.The improved duplex real-time PCR was further validated using processed foods derived from GM soybean,and more accurate GM content values in these foods was also achieved.These results demonstrated that the improved duplex real-time PCR would be quite suitable in quantitative detection of high processed food products.

  17. Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors

    Directory of Open Access Journals (Sweden)

    Minho Choi

    2016-05-01

    Full Text Available Non-intrusive electrocardiogram (ECG monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ECG sensors (cECGs to measure ECG, and another two cECGs located adjacent to the sensors for ECG are added to obtain the information on motion. Then, active noise cancellation technique and the motion information are used to reduce motion noise. To verify the proposed method, ECG was measured indoors and during driving, and the accuracy of the detected R peaks was compared. After applying the method, the sum of sensitivity and positive predictivity increased 8.39% on average and 26.26% maximally in the data. Based on the results, it was confirmed that the motion noise was reduced and that more reliable R peak positions could be obtained by the proposed method. The robustness of the new ECG measurement method will elicit benefits to various health care systems that require noninvasive heart rate or heart rate variability measurements.

  18. Accuracy of digital radiography and cone beam computed tomography on periapical radiolucency detection in endodontically treated teeth.

    Science.gov (United States)

    Venskutonis, Tadas; Daugela, Povilas; Strazdas, Marijus; Juodzbalys, Gintaras

    2014-04-01

    The aim of the present study was to compare the accuracy of intraoral digital periapical radiography and cone beam computed tomography in the detection of periapical radiolucencies in endodontically treated teeth. Radiographic images (cone beam computed tomography [CBCT] scans and digital periapical radiography [PR] images) from 60 patients, achieved from September 2008 to July 2013, were retrieved from databases of the Department of Oral Diseases, Lithuanian University of Health Sciences. Twenty patients met inclusion criteria and were selected for further evaluation. In 20 patients (42.4 [SD 12.1] years, 65% men and 35% women) a total of 35 endodontically treated teeth (1.75 [SD 0.91]; 27 in maxilla and 8 in mandible) were evaluated. Overall, it was observed a statistical significant difference between the number of periapical lesions observed in the CBCT (n = 42) and radiographic (n = 24) examinations (P cone beam computed tomography scans were more accurate compared to digital periapical radiographs for detecting periapical radiolucencies in endodontically treated teeth. The difference was more pronounced in molar teeth.

  19. Improved QRD-M Detection Algorithm for Generalized Spatial Modulation Scheme

    Directory of Open Access Journals (Sweden)

    Xiaorong Jing

    2017-01-01

    Full Text Available Generalized spatial modulation (GSM is a spectral and energy efficient multiple-input multiple-output (MIMO transmission scheme. It will lead to imperfect detection performance with relatively high computational complexity by directly applying the original QR-decomposition with M algorithm (QRD-M to the GSM scheme. In this paper an improved QRD-M algorithm is proposed for GSM signal detection, which achieves near-optimal performance but with relatively low complexity. Based on the QRD, the improved algorithm firstly transforms the maximum likelihood (ML detection of the GSM signals into searching an inverted tree structure. Then, in the searching process of the M branches, the branches corresponding to the illegitimate transmit antenna combinations (TACs and related to invalid number of active antennas are cut in order to improve the validity of the resultant branches at each level by taking advantage of characteristics of GSM signals. Simulation results show that the improved QRD-M detection algorithm provides similar performance to maximum likelihood (ML with the reduced computational complexity compared to the original QRD-M algorithm, and the optimal value of parameter M of the improved QRD-M algorithm for detection of the GSM scheme is equal to modulation order plus one.

  20. DARK MATTER SUBSTRUCTURE DETECTION USING SPATIALLY RESOLVED SPECTROSCOPY OF LENSED DUSTY GALAXIES

    International Nuclear Information System (INIS)

    Hezaveh, Yashar; Holder, Gilbert; Dalal, Neal; Kuhlen, Michael; Marrone, Daniel; Murray, Norman; Vieira, Joaquin

    2013-01-01

    We investigate how strong lensing of dusty, star-forming galaxies (DSFGs) by foreground galaxies can be used as a probe of dark matter halo substructure. We find that spatially resolved spectroscopy of lensed sources allows dramatic improvements to measurements of lens parameters. In particular, we find that modeling of the full, three-dimensional (angular position and radial velocity) data can significantly facilitate substructure detection, increasing the sensitivity of observables to lower mass subhalos. We carry out simulations of lensed dusty sources observed by early ALMA (Cycle 1) and use a Fisher matrix analysis to study the parameter degeneracies and mass detection limits of this method. We find that even with conservative assumptions, it is possible to detect galactic dark matter subhalos of ∼10 8 M ☉ with high significance in most lensed DSFGs. Specifically, we find that in typical DSFG lenses, there is a ∼55% probability of detecting a substructure with M > 10 8 M ☉ with more than 5σ detection significance in each lens, if the abundance of substructure is consistent with previous lensing results. The full ALMA array, with its significantly enhanced sensitivity and resolution, should improve these estimates considerably. Given the sample of ∼100 lenses provided by surveys such as the South Pole Telescope, our understanding of dark matter substructure in typical galaxy halos is poised to improve dramatically over the next few years.

  1. DARK MATTER SUBSTRUCTURE DETECTION USING SPATIALLY RESOLVED SPECTROSCOPY OF LENSED DUSTY GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Hezaveh, Yashar; Holder, Gilbert [Department of Physics, McGill University, 3600 Rue University, Montreal, Quebec H3A 2T8 (Canada); Dalal, Neal [Astronomy Department, University of Illinois at Urbana-Champaign, 1002 West Green Street, Urbana, IL 61801 (United States); Kuhlen, Michael [Theoretical Astrophysics Center, University of California, Berkeley, CA 94720 (United States); Marrone, Daniel [Steward Observatory, University of Arizona, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Murray, Norman [CITA, University of Toronto, 60 St. George Street, Toronto, ON M5S 3H8 (Canada); Vieira, Joaquin [California Institute of Technology, 1200 East California Blvd, MC 249-17, Pasadena, CA 91125 (United States)

    2013-04-10

    We investigate how strong lensing of dusty, star-forming galaxies (DSFGs) by foreground galaxies can be used as a probe of dark matter halo substructure. We find that spatially resolved spectroscopy of lensed sources allows dramatic improvements to measurements of lens parameters. In particular, we find that modeling of the full, three-dimensional (angular position and radial velocity) data can significantly facilitate substructure detection, increasing the sensitivity of observables to lower mass subhalos. We carry out simulations of lensed dusty sources observed by early ALMA (Cycle 1) and use a Fisher matrix analysis to study the parameter degeneracies and mass detection limits of this method. We find that even with conservative assumptions, it is possible to detect galactic dark matter subhalos of {approx}10{sup 8} M{sub Sun} with high significance in most lensed DSFGs. Specifically, we find that in typical DSFG lenses, there is a {approx}55% probability of detecting a substructure with M > 10{sup 8} M{sub Sun} with more than 5{sigma} detection significance in each lens, if the abundance of substructure is consistent with previous lensing results. The full ALMA array, with its significantly enhanced sensitivity and resolution, should improve these estimates considerably. Given the sample of {approx}100 lenses provided by surveys such as the South Pole Telescope, our understanding of dark matter substructure in typical galaxy halos is poised to improve dramatically over the next few years.

  2. Deep Spatial-Temporal Joint Feature Representation for Video Object Detection

    Directory of Open Access Journals (Sweden)

    Baojun Zhao

    2018-03-01

    Full Text Available With the development of deep neural networks, many object detection frameworks have shown great success in the fields of smart surveillance, self-driving cars, and facial recognition. However, the data sources are usually videos, and the object detection frameworks are mostly established on still images and only use the spatial information, which means that the feature consistency cannot be ensured because the training procedure loses temporal information. To address these problems, we propose a single, fully-convolutional neural network-based object detection framework that involves temporal information by using Siamese networks. In the training procedure, first, the prediction network combines the multiscale feature map to handle objects of various sizes. Second, we introduce a correlation loss by using the Siamese network, which provides neighboring frame features. This correlation loss represents object co-occurrences across time to aid the consistent feature generation. Since the correlation loss should use the information of the track ID and detection label, our video object detection network has been evaluated on the large-scale ImageNet VID dataset where it achieves a 69.5% mean average precision (mAP.

  3. Deep Spatial-Temporal Joint Feature Representation for Video Object Detection.

    Science.gov (United States)

    Zhao, Baojun; Zhao, Boya; Tang, Linbo; Han, Yuqi; Wang, Wenzheng

    2018-03-04

    With the development of deep neural networks, many object detection frameworks have shown great success in the fields of smart surveillance, self-driving cars, and facial recognition. However, the data sources are usually videos, and the object detection frameworks are mostly established on still images and only use the spatial information, which means that the feature consistency cannot be ensured because the training procedure loses temporal information. To address these problems, we propose a single, fully-convolutional neural network-based object detection framework that involves temporal information by using Siamese networks. In the training procedure, first, the prediction network combines the multiscale feature map to handle objects of various sizes. Second, we introduce a correlation loss by using the Siamese network, which provides neighboring frame features. This correlation loss represents object co-occurrences across time to aid the consistent feature generation. Since the correlation loss should use the information of the track ID and detection label, our video object detection network has been evaluated on the large-scale ImageNet VID dataset where it achieves a 69.5% mean average precision (mAP).

  4. Accuracy of detection of carboxyhemoglobin and methemoglobin in human and bovine blood with an inexpensive, pocket-size infrared scanner.

    Directory of Open Access Journals (Sweden)

    Margot P Bickler

    Full Text Available Detecting life-threatening common dyshemoglobins such as carboxyhemoglobin (COHb, resulting from carbon monoxide poisoning or methemoglobin (MetHb, caused by exposure to nitrates typically requires a laboratory CO-oximeter. Because of cost, these spectrophotometer-based instrument are often inaccessible in resource-poor settings. The aim of this study was to determine if an inexpensive pocket infrared spectrometer and smartphone (SCiO®Pocket Molecular Sensor, Consumer Physics Ltd., Israel accurately detects COHb and MetHb in single drops of blood. COHb was created by adding carbon monoxide gas to syringes of heparinized blood human or cow blood. In separate syringes, MetHb was produced by addition of sodium nitrite solution. After incubation and mixing, fractional concentrations of COHb or MetHb were measured using a Radiometer ABL-90 Flex® CO-oximeter. Fifty microliters of the sample were then placed on a microscope slide, a cover slip applied and scanned with the SCiO spectrometer. The spectrograms were used to create simple linear models predicting [COHb] or [MetHb] based on spectrogram maxima, minima and isobestic wavelengths. Our model predicted clinically significant carbon monoxide poisoning (COHb ≥15% with a sensitivity of 93% and specificity of 88% (regression r2 = 0.63, slope P20% MetHb was detected with a sensitivity of 100% and specificity of 71% (regression r2 = 0.92, slope P15% COHb or >20% MetHb on a single drop of blood with enough accuracy to be useful as an initial clinical screening. The SCiO and similar relatively low cost spectrometers could be developed as inexpensive diagnostic tools for developing countries.

  5. Accuracy of Medical Students in Detecting Pleural Effusion Using Lung Ultrasound as an Adjunct to the Physical Examination.

    Science.gov (United States)

    Steinmetz, Peter; Oleskevich, Sharon; Dyachenko, Alina; McCusker, Jane; Lewis, John

    2018-03-25

    This study compared the accuracy of medical students in identifying pleural effusion in hospitalized patients using the physical examination versus lung ultrasound (US). Fourth-year medical students (n = 14) received 20 hours of general practical US training (including 2 hours of specialized lung US training) plus theoretical and video documentation. The students used the physical examination alone versus the physical examination plus lung US to document the presence or absence of pleural effusion in the right and left hemithoraces of hospitalized patients (n = 11 patients; 22 hemithoraces examined 544 times in total). The reference standard for identification of pleural effusion was a lung US examination by 2 expert point-of-care sonographers. The odds of correctly identifying the presence versus absence of pleural effusion was 5 times greater with lung US as an adjunct to the physical examination compared to the physical examination alone (odds ratio [OR], 5.1 from multivariate logistic regression; 95% confidence interval, 3.3-8.0). The addition of lung US to the physical examination resulted in an increase in sensitivity from 48% to 90%, in specificity from 73% to 86%, and in accuracy from 60% to 88%. The benefits of using US were greater when pleural effusion was present versus absent (OR, 10.8 versus 2.4) and when examining older versus younger patients (OR, 10.2 versus 2.8). These results demonstrate that medical students' ability to detect the presence or absence of pleural effusion is superior when using lung US as an adjunct to the physical examination than when using the physical examination alone. © 2018 by the American Institute of Ultrasound in Medicine.

  6. The diagnostic accuracy of serologic and molecular methods for detecting visceral leishmaniasis in HIV infected patients: meta-analysis.

    Directory of Open Access Journals (Sweden)

    Gláucia Fernandes Cota

    Full Text Available BACKGROUND: Human visceral leishmaniasis (VL, a potentially fatal disease, has emerged as an important opportunistic condition in HIV infected patients. In immunocompromised patients, serological investigation is considered not an accurate diagnostic method for VL diagnosis and molecular techniques seem especially promising. OBJECTIVE: This work is a comprehensive systematic review and meta-analysis to evaluate the accuracy of serologic and molecular tests for VL diagnosis specifically in HIV-infected patients. METHODS: Two independent reviewers searched PubMed and LILACS databases. The quality of studies was assessed by QUADAS score. Sensitivity and specificity were pooled separately and compared with overall accuracy measures: diagnostic odds ratio (DOR and symmetric summary receiver operating characteristic (sROC. RESULTS: Thirty three studies recruiting 1,489 patients were included. The following tests were evaluated: Immunofluorescence Antibody Test (IFAT, Enzyme linked immunosorbent assay (ELISA, immunoblotting (Blot, direct agglutination test (DAT and polimerase chain reaction (PCR in whole blood and bone marrow. Most studies were carried out in Europe. Serological tests varied widely in performance, but with overall limited sensitivity. IFAT had poor sensitivity ranging from 11% to 82%. DOR (95% confidence interval was higher for DAT 36.01 (9.95-130.29 and Blot 27.51 (9.27-81.66 than for IFAT 7.43 (3.08-1791 and ELISA 3.06 (0.71-13.10. PCR in whole blood had the highest DOR: 400.35 (58.47-2741.42. The accuracy of PCR based on Q-point was 0.95; 95%CI 0.92-0.97, which means good overall performance. CONCLUSION: Based mainly on evidence gained by infection with Leishmania infantum chagasi, serological tests should not be used to rule out a diagnosis of VL among the HIV-infected, but a positive test at even low titers has diagnostic value when combined with the clinical case definition. Considering the available evidence, tests based on DNA

  7. Intrinsic spatial resolution limitations due to differences between positron emission position and annihilation detection localization

    International Nuclear Information System (INIS)

    Perez, Pedro; Malano, Francisco; Valente, Mauro

    2012-01-01

    Since its successful implementation for clinical diagnostic, positron emission tomography (PET) represents the most promising medical imaging technique. The recent major growth of PET imaging is mainly due to its ability to trace the biologic pathways of different compounds in the patient's body, assuming the patient can be labeled with some PET isotope. Regardless of the type of isotope, the PET imaging method is based on the detection of two 511-keV gamma photons being emitted in opposite directions, with almost 180 deg between them, as a consequence of electron-positron annihilation. Therefore, this imaging method is intrinsically limited by random uncertainties in spatial resolutions, related with differences between the actual position of positron emission and the location of the detected annihilation. This study presents an approach with the Monte Carlo method to analyze the influence of this effect on different isotopes of potential implementation in PET. (author)

  8. Blind detection of isolated astrophysical pulses in the spatial Fourier transform domain

    Science.gov (United States)

    Schmid, Natalia A.; Prestage, Richard M.

    2018-04-01

    We present a novel approach for the detection of isolated transients in pulsar surveys and fast radio transient observations. Rather than the conventional approach of performing a computationally expensive blind DM search, we take the spatial Fourier transform (SFT) of short (˜ few seconds) sections of data. A transient will have a characteristic signature in the SFT domain, and we present a blind statistic which may be used to detect this signature at an empirical zero False Alarm Rate (FAR). The method has been evaluated using simulations, and also applied to two fast radio burst observations. In addition to its use for current observations, we expect this method will be extremely beneficial for future multi-beam observations made by telescopes equipped with phased array feeds.

  9. Can breast MRI computer-aided detection (CAD) improve radiologist accuracy for lesions detected at MRI screening and recommended for biopsy in a high-risk population?

    International Nuclear Information System (INIS)

    Arazi-Kleinman, T.; Causer, P.A.; Jong, R.A.; Hill, K.; Warner, E.

    2009-01-01

    Aim: To evaluate the sensitivity and specificity of magnetic resonance imaging (MRI) computer-aided detection (CAD) for breast MRI screen-detected lesions recommended for biopsy in a high-risk population. Material and methods: Fifty-six consecutive Breast Imaging Reporting and Data System (BI-RADS) 3-5 lesions with histopathological correlation [nine invasive cancers, 13 ductal carcinoma in situ (DCIS) and 34 benign] were retrospectively evaluated using a breast MRI CAD prototype (CAD-Gaea). CAD evaluation was performed separately and in consensus by two radiologists specializing in breast imaging, blinded to the histopathology. Thresholds of 50, 80, and 100% and delayed enhancement were independently assessed with CAD. Lesions were rated as malignant or benign according to threshold and delayed enhancement only and in combination. Sensitivities, specificities, and negative predictive values (NPV) were determined for CAD assessments versus pathology. Initial MRI BI-RADS interpretation without CAD versus CAD assessments were compared using paired binary diagnostic tests. Results: Threshold levels for lesion enhancement were: 50% to include all malignant (and all benign) lesions; and 100% for all invasive cancer and high-grade DCIS. Combined use of threshold and enhancement patterns for CAD assessment was best (73% sensitivity, 56% specificity and 76% NPV for all cancer). Sensitivities and NPV were better for invasive cancer (100%/100%) than for all malignancies (54%/76%). Radiologists' MRI interpretation was more sensitive than CAD (p = 0.05), but less specific (p = 0.001) for cancer detection. Conclusion: The breast MRI CAD system used could not improve the radiologists' accuracy for distinguishing all malignant from benign lesions, due to the poor sensitivity for DCIS detection.

  10. Speech detection in noise and spatial unmasking in children with simultaneous versus sequential bilateral cochlear implants.

    Science.gov (United States)

    Chadha, Neil K; Papsin, Blake C; Jiwani, Salima; Gordon, Karen A

    2011-09-01

    To measure speech detection in noise performance for children with bilateral cochlear implants (BiCI), to compare performance in children with simultaneous implant versus those with sequential implant, and to compare performance to normal-hearing children. Prospective cohort study. Tertiary academic pediatric center. Children with early-onset bilateral deafness and 2-year BiCI experience, comprising the "sequential" group (>2 yr interimplantation delay, n = 12) and "simultaneous group" (no interimplantation delay, n = 10) and normal-hearing controls (n = 8). Thresholds to speech detection (at 0-degree azimuth) were measured with noise at 0-degree azimuth or ± 90-degree azimuth. Spatial unmasking (SU) as the noise condition changed from 0-degree azimuth to ± 90-degree azimuth and binaural summation advantage (BSA) of 2 over 1 CI. Speech detection in noise was significantly poorer than controls for both BiCI groups (p simultaneous group approached levels found in normal controls (7.2 ± 0.6 versus 8.6 ± 0.6 dB, p > 0.05) and was significantly better than that in the sequential group (3.9 ± 0.4 dB, p simultaneous group but, in the sequential group, was significantly better when noise was moved to the second rather than the first implanted ear (4.8 ± 0.5 versus 3.0 ± 0.4 dB, p sequential group's second rather than first CI. Children with simultaneously implanted BiCI demonstrated an advantage over children with sequential implant by using spatial cues to improve speech detection in noise.

  11. The diagnostic accuracy of a single CEA blood test in detecting colorectal cancer recurrence: Results from the FACS trial.

    Directory of Open Access Journals (Sweden)

    Bethany Shinkins

    Full Text Available To evaluate the diagnostic accuracy of a single CEA (carcinoembryonic antigen blood test in detecting colorectal cancer recurrence.Patients who have undergone curative resection for primary colorectal cancer are typically followed up with scheduled CEA testing for 5 years. Decisions to investigate further (usually by CT imaging are based on single test results, reflecting international guidelines.A secondary analysis was undertaken of data from the FACS trial (two arms included CEA testing. The composite reference standard applied included CT-CAP imaging, clinical assessment and colonoscopy. Accuracy in detecting recurrence was evaluated in terms of sensitivity, specificity, likelihood ratios, predictive values, time-dependent area under the ROC curves, and operational performance when used prospectively in clinical practice are reported.Of 582 patients, 104 (17.9% developed recurrence during the 5 year follow-up period. Applying the recommended threshold of 5μg/L achieves at best 50.0% sensitivity (95% CI: 40.1-59.9%; in prospective use in clinical practice it would lead to 56 missed recurrences (53.8%; 95% CI: 44.2-64.4% and 89 false alarms (56.7% of 157 patients referred for investigation. Applying a lower threshold of 2.5μg/L would reduce the number of missed recurrences to 36.5% (95% CI: 26.5-46.5% but would increase the false alarms to 84.2% (924/1097 referred. Some patients are more prone to false alarms than others-at the 5μg/L threshold, the 89 episodes of unnecessary investigation were clustered in 29 individuals.Our results demonstrated very low sensitivity for CEA, bringing to question whether it could ever be used as an independent triage test. It is not feasible to improve the diagnostic performance of a single test result by reducing the recommended action threshold because of the workload and false alarms generated. Current national and international guidelines merit re-evaluation and options to improve performance, such as

  12. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    Science.gov (United States)

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake

  13. A spatial approach of magnitude-squared coherence applied to selective attention detection.

    Science.gov (United States)

    Bonato Felix, Leonardo; de Souza Ranaudo, Fernando; D'affonseca Netto, Aluizio; Ferreira Leite Miranda de Sá, Antonio Mauricio

    2014-05-30

    Auditory selective attention is the human ability of actively focusing in a certain sound stimulus while avoiding all other ones. This ability can be used, for example, in behavioral studies and brain-machine interface. In this work we developed an objective method - called Spatial Coherence - to detect the side where a subject is focusing attention to. This method takes into consideration the Magnitude Squared Coherence and the topographic distribution of responses among electroencephalogram electrodes. The individuals were stimulated with amplitude-modulated tones binaurally and were oriented to focus attention to only one of the stimuli. The results indicate a contralateral modulation of ASSR in the attention condition and are in agreement with prior studies. Furthermore, the best combination of electrodes led to a hit rate of 82% for 5.03 commands per minute. Using a similar paradigm, in a recent work, a maximum hit rate of 84.33% was achieved, but with a greater a classification time (20s, i.e. 3 commands per minute). It seems that Spatial Coherence is a useful technique for detecting focus of auditory selective attention. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Penalized likelihood and multi-objective spatial scans for the detection and inference of irregular clusters

    Directory of Open Access Journals (Sweden)

    Fonseca Carlos M

    2010-10-01

    Full Text Available Abstract Background Irregularly shaped spatial clusters are difficult to delineate. A cluster found by an algorithm often spreads through large portions of the map, impacting its geographical meaning. Penalized likelihood methods for Kulldorff's spatial scan statistics have been used to control the excessive freedom of the shape of clusters. Penalty functions based on cluster geometry and non-connectivity have been proposed recently. Another approach involves the use of a multi-objective algorithm to maximize two objectives: the spatial scan statistics and the geometric penalty function. Results & Discussion We present a novel scan statistic algorithm employing a function based on the graph topology to penalize the presence of under-populated disconnection nodes in candidate clusters, the disconnection nodes cohesion function. A disconnection node is defined as a region within a cluster, such that its removal disconnects the cluster. By applying this function, the most geographically meaningful clusters are sifted through the immense set of possible irregularly shaped candidate cluster solutions. To evaluate the statistical significance of solutions for multi-objective scans, a statistical approach based on the concept of attainment function is used. In this paper we compared different penalized likelihoods employing the geometric and non-connectivity regularity functions and the novel disconnection nodes cohesion function. We also build multi-objective scans using those three functions and compare them with the previous penalized likelihood scans. An application is presented using comprehensive state-wide data for Chagas' disease in puerperal women in Minas Gerais state, Brazil. Conclusions We show that, compared to the other single-objective algorithms, multi-objective scans present better performance, regarding power, sensitivity and positive predicted value. The multi-objective non-connectivity scan is faster and better suited for the

  15. Remote sensing and spatial analysis based study for detecting deforestation and the associated drivers

    Science.gov (United States)

    El-Abbas, Mustafa M.; Csaplovics, Elmar; Deafalla, Taisser H.

    2013-10-01

    Nowadays, remote-sensing technologies are becoming increasingly interlinked to the issue of deforestation. They offer a systematized and objective strategy to document, understand and simulate the deforestation process and its associated causes. In this context, the main goal of this study, conducted in the Blue Nile region of Sudan, in which most of the natural habitats were dramatically destroyed, was to develop spatial methodologies to assess the deforestation dynamics and its associated factors. To achieve that, optical multispectral satellite scenes (i.e., ASTER and LANDSAT) integrated with field survey in addition to multiple data sources were used for the analyses. Spatiotemporal Object Based Image Analysis (STOBIA) was applied to assess the change dynamics within the period of study. Broadly, the above mentioned analyses include; Object Based (OB) classifications, post-classification change detection, data fusion, information extraction and spatial analysis. Hierarchical multi-scale segmentation thresholds were applied and each class was delimited with semantic meanings by a set of rules associated with membership functions. Consequently, the fused multi-temporal data were introduced to create detailed objects of change classes from the input LU/LC classes. The dynamic changes were quantified and spatially located as well as the spatial and contextual relations from adjacent areas were analyzed. The main finding of the present study is that, the forest areas were drastically decreased, while the agrarian structure in conversion of forest into agricultural fields and grassland was the main force of deforestation. In contrast, the capability of the area to recover was clearly observed. The study concludes with a brief assessment of an 'oriented' framework, focused on the alarming areas where serious dynamics are located and where urgent plans and interventions are most critical, guided with potential solutions based on the identified driving forces.

  16. Wind turbine extraction from high spatial resolution remote sensing images based on saliency detection

    Science.gov (United States)

    Chen, Jingbo; Yue, Anzhi; Wang, Chengyi; Huang, Qingqing; Chen, Jiansheng; Meng, Yu; He, Dongxu

    2018-01-01

    The wind turbine is a device that converts the wind's kinetic energy into electrical power. Accurate and automatic extraction of wind turbine is instructive for government departments to plan wind power plant projects. A hybrid and practical framework based on saliency detection for wind turbine extraction, using Google Earth image at spatial resolution of 1 m, is proposed. It can be viewed as a two-phase procedure: coarsely detection and fine extraction. In the first stage, we introduced a frequency-tuned saliency detection approach for initially detecting the area of interest of the wind turbines. This method exploited features of color and luminance, was simple to implement, and was computationally efficient. Taking into account the complexity of remote sensing images, in the second stage, we proposed a fast method for fine-tuning results in frequency domain and then extracted wind turbines from these salient objects by removing the irrelevant salient areas according to the special properties of the wind turbines. Experiments demonstrated that our approach consistently obtains higher precision and better recall rates. Our method was also compared with other techniques from the literature and proves that it is more applicable and robust.

  17. SU-F-T-645: To Test Spatial Anddosimetric Accuracy of Small Cranial Target Irradiation Based On 1.5 T MRIscans Using Static Arcs with MLCDefined Fields

    International Nuclear Information System (INIS)

    Brezovich, I; Wu, X; Popple, R; Shen, S; Cardan, R; Bolding, M; Fiveash, J; Kraus, J; Spencer, S

    2016-01-01

    Purpose: To test spatial and dosimetric accuracy of small cranial target irradiation based on 1.5 T MRI scans using static arcs with MLC-defined fields Methods: A plastic (PMMA) phantom simulating a small brain lesion was mounted on a GammaKnife headframe equipped with MRI localizer. The lesion was a 3 mm long, 3.175 mm diameter cylindrical cavity filled with MRI contrast. Radiochromic film passing through the cavity was marked with pin pricks at the cavity center. The cavity was contoured on an MRI image and fused with CT to simulate treatment of a lesion not visible on CT. The transfer of the target to CT involved registering the MRI contrast cannels of the localizer that were visible on both modalities. Treatments were planned to deliver 800 cGy to the cavity center using multiple static arcs with 5.0×2.4 mm MLC-defined fields. The phantom was aligned on a STx accelerator by registering the conebeam CT with the planning CT. Films from coronal and sagittal planes were scanned and evaluated using ImageJ software Results: Geographic errors in treatment based on 1.5 T scans agreed within 0.33, −0.27 and 1.21 mm in the vertical, lateral and longitudinal dimensions, respectively. The doses delivered to the cavity center were 7.2% higher than planned. The dose distributions were similar to those of a GammaKnife. Conclusion: Radiation can be delivered with an accelerator at mm accuracy to small cranial targets based on 1.5 MRI scans fused to CTs using a standard GammaKnife headframe and MRI localizer. MLC-defined static arcs produce isodose lines very similar to the GammaKnife.

  18. Do tumor size or patient age influence the accuracy of sentinel lymph node (Sn) detection in breast cancer?

    International Nuclear Information System (INIS)

    Cortes, M.; Fernandez, A.; Benito, E.; Azpeitia, D.; Ricart, Y.; Escobedo, A.; Martin-Comin, J.

    2002-01-01

    Full text: The aim was to analyze the influence of the age of the patient and tumor size on the accuracy to identify SN in patients with breast cancer. The whole population are 250 patients with breast cancer. In 236 data on size and age were available. Mean age was 53.6 years, range 28-87 years. Patients were classified 1) depending an age: 40 60 years: 73 p and 2) depending on tumor size (mm): 30: 46 p. Examination protocol: All patients received a peritumoral injection of 111 MBq (3mCi) of 99mTc-HSA-nanocolloid in 1 - 3 ml. 2 h later 300 seconds anterior and lateral thoracic scans were obtained. A 57-Co flood phantom was positioned back to the patient to outline the anatomical contour and help to localize SN. SN was marked on the skin with permanent ink. Intraoperative SN localization was performed using a gamma probe. Histopathologic analysis of SN was done with haematoxylin/eosin, immunohistochemistry and PCR. Histopathology of the SN was compared to the histopathology of all the other lymph nodes drawn out by the surgeon. SN were identified by lymphoscintigraphy in 227 cases of 250 (91 %). 221 of them (97 %) were localized in axyla. In 210 of 221 SN could be localized and drawn out at surgery. The no detection and false negative rate were much higher in patients aged > 60 (29 and 33 %) and in tumors > 30 mm (32 and 19 %) than in patients 60 y and tumors > 30 mm (46 %) and the highest false negative rate appears in patients >60 and tumors > 30 mm (33 %) 1) No FN were found in patients with tumor size <10 mm. 2) No FN were found in patients aged under 40 years. 3) FN rate seems to be higher in older patients. 4) The age of patients and the size of tumor seem to influence an the SN detection rates. (author)

  19. The characteristics and spatial distributions of initially missed and rebiopsy-detected prostate cancers

    Directory of Open Access Journals (Sweden)

    Myung-Won You

    2016-07-01

    Full Text Available Purpose: The purpose of this study was to analyze the characteristics of initially missed and rebiopsy-detected prostate cancers following 12-core transrectal biopsy. Methods: A total of 45 patients with prostate cancers detected on rebiopsy and 45 patients with prostate cancers initially detected on transrectal ultrasound-guided biopsy were included in the study. For result analysis, the prostate was divided into six compartments, and the cancer positive rates, estimated tumor burden, and agreement rates between biopsy and surgical specimens, along with clinical data, were evaluated. Results: The largest mean tumor burden was located in the medial apex in both groups. There were significantly more tumors in this location in the rebiopsy group (44.9% than in the control group (30.1%, P=0.015. The overall sensitivity of biopsy was significantly lower in the rebiopsy group (22.5% vs. 43.4%, P<0.001. The agreement rate of cancer positive cores between biopsy and surgical specimens was significantly lower in the medial apex in the rebiopsy group compared with that of the control group (50.0% vs. 65.6%, P=0.035. The cancer positive rates of target biopsy cores and premalignant lesions in the rebiopsy group were 63.1% and 42.3%, respectively. Conclusion: Rebiopsy-detected prostate cancers showed different spatial distribution and lower cancer detection rate of biopsy cores compared with initially diagnosed cancers. To overcome lower cancer detection rate, target biopsy of abnormal sonographic findings, premalignant lesions and medial apex which revealed larger tumor burden would be recommended when performing rebiopsy.

  20. Radiofrequency ablation of renal tumours: diagnostic accuracy of contrast-enhanced ultrasound for early detection of residual tumour

    International Nuclear Information System (INIS)

    Hoeffel, Christine; Pousset, Maud; Elie, Caroline; Timsit, Marc-Olivier; Mejean, Arnaud; Merran, Samuel; Tranquart, Francois; Khairoune, Ahmed; Helenon, Olivier; Correas, Jean-Michel; Joly, Dominique; Richard, Stephane

    2010-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in the early detection of residual tumour after radiofrequency ablation (RFA) of renal tumours. Patients referred to our institution for RFA of renal tumours prospectively underwent CEUS and computed tomography (CT) or magnetic resonance imaging (MRI) before, within 1 day and 6 weeks after treatment. Identification of residual tumour was assessed by three blinded radiologists. Reference standard was CT/MRI performed at least 1 year after RFA. A total of 66 renal tumours in 43 patients (median age 62 years; range 44-71.5) were studied. Inter-reader agreement (κ value) was 0.84 for CEUS. Prevalence of residual disease was 19%. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), respectively, were as follows: 64% [confidence interval (CI) 39-84], 98% [CI 91-100], 82% [CI 52-95] and 92% [CI 83-97] on 24-h CEUS; 79% [CI 52-92], 100% [CI 94-100], 100% [CI 74-100] and 95% [CI 87-100] on 6-week CEUS; 79% [CI 52-92], 95% [CI 86-98], 79% [CI 52-92] and 95% [CI 86-98] on 24-h CT/MRI; and 100% [CI 72-100], 98% [CI 90-100], 91% [CI 62-98] and 100% [CI 93-100] on 6-week CT/MRI. CEUS has high specificity for the early diagnosis of residual tumour after renal RFA. (orig.)

  1. Diagnostic accuracy of a loop-mediated isothermal PCR assay for detection of Orientia tsutsugamushi during acute Scrub Typhus infection.

    Science.gov (United States)

    Paris, Daniel H; Blacksell, Stuart D; Nawtaisong, Pruksa; Jenjaroen, Kemajittra; Teeraratkul, Achara; Chierakul, Wirongrong; Wuthiekanun, Vanaporn; Kantipong, Pacharee; Day, Nicholas P J

    2011-09-01

    There is an urgent need to develop rapid and accurate point-of-care (POC) technologies for acute scrub typhus diagnosis in low-resource, primary health care settings to guide clinical therapy. In this study we present the clinical evaluation of loop-mediated isothermal PCR assay (LAMP) in the context of a prospective fever study, including 161 patients from scrub typhus-endemic Chiang Rai, northern Thailand. A robust reference comparator set comprising following 'scrub typhus infection criteria' (STIC) was used: a) positive cell culture isolate and/or b) an admission IgM titer ≥1∶12,800 using the 'gold standard' indirect immunofluorescence assay (IFA) and/or c) a 4-fold rising IFA IgM titer and/or d) a positive result in at least two out of three PCR assays. Compared to the STIC criteria, all PCR assays (including LAMP) demonstrated high specificity ranging from 96-99%, with sensitivities varying from 40% to 56%, similar to the antibody based rapid test, which had a sensitivity of 47% and a specificity of 95%. The diagnostic accuracy of the LAMP assay was similar to realtime and nested conventional PCR assays, but superior to the antibody-based rapid test in the early disease course. The combination of DNA- and antibody-based detection methods increased sensitivity with minimal reduction of specificity, and expanded the timeframe of adequate diagnostic coverage throughout the acute phase of scrub typhus.

  2. Combining time-frequency and spatial information for the detection of sleep spindles

    Directory of Open Access Journals (Sweden)

    Christian eO'Reilly

    2015-02-01

    Full Text Available EEG sleep spindles are short (0.5-2.0 s bursts of activity in the 11-16 Hz band occurring during non-rapid eye movement (NREM sleep. This sporadic activity is thought to play a role in memory consolidation, brain plasticity, and protection of sleep integrity. Many automatic detectors have been proposed to assist or replace experts for sleep spindle scoring. However, these algorithms usually detect too many events making it difficult to achieve a good tradeoff between sensitivity (Se and false detection rate (FDr. In this work, we propose a semi-automatic detector comprising a sensitivity phase based on well-established criteria followed by a specificity phase using spatial and spectral criteria.In the sensitivity phase, selected events are those which amplitude in the 10 – 16 Hz band and spectral ratio characteristics both reject a null hypothesis (p <0.1 stating that the considered event is not a spindle. This null hypothesis is constructed from events occurring during rapid eye movement (REM sleep epochs. In the specificity phase, a hierarchical clustering of the selected candidates is done based on events’ frequency and spatial position along the anterior-posterior axis. Only events from the classes grouping most (at least 80% spindles scored by an expert are kept. We obtain Se = 93.2% and FDr = 93.0% in the first phase and Se = 85.4% and FDr = 86.2% in the second phase. For these two phases, Matthew’s correlation coefficients are respectively 0.228 and 0.324. Results suggest that spindles are defined by specific spatio-spectral properties and that automatic detection methods can be improved by considering these features.

  3. Diagnostic accuracy of commercial system for computer-assisted detection (CADx) as an adjunct to interpretation of mammograms

    International Nuclear Information System (INIS)

    Menna, Sabatino; Di Virgilio, Maria Rosaria; Burke, Paolo; Frigerio, Alfonso; Boglione, Elisa; Ciccarelli, Grazia; Di Filippo, Sabato; Garretti, Licia

    2005-01-01

    Purpose. To evaluate the diagnostic accuracy of the commercial computer-aided detection CADx system for the reading of mammograms. Materials and methods. The study assessed the Second Look system developed and marketed by CADx Medical Systems, Montreal, Canada. The diagnostic sensitivity was evaluated by means of a retrospective study on 98 consecutive cancers detected at screening by double independent reading. The specificity and the positive predictive value (PPV) for cancer of the CADx system were prospectively evaluated on a second group of 560 consecutive mammograms of asymptomatic women not included in screening program. The radiologist who was present during the test assessed the abnormal mammographic findings by one or more of the following diagnostic procedures: physical examination, additional mammographic detail views with or without magnification,ultrasonography, ultrasound- or mammography guided fine needle aspiration cytology, and core-biopsy. The exams first underwent conventional reading and then a second reading carried out with the aid of the CADx system. Results.The overall diagnostic sensitivity of the CADx system on the 98 screening cancers was 81.6%; in particular it was 89.3% for calcifications, 83.9% for masses and only 37.5% for architectural distortion. The CADx markings for each mammography were 4.7 on average. Identification of invasive carcinoma was independent from tumour size. In the second group of 560 mammograms, the CADx system marked all cases identified as positive by conventional reading and confirmed by biopsy (7/7), but did not permit the detection of any additional cancer. The CADx markings per exam were 4.2 on average, the specificity was 13.7% and the PPV was 0.55% versus 13.7% recall rate of conventional reading. CADx reading led to a 1.96% (11/560) increase of the women necessitating further diagnostic investigation. Conclusions. The results of our study show that the diagnostic sensitivity of the CADx system is lower

  4. Accuracy and uncertainty analysis of soil Bbf spatial distribution estimation at a coking plant-contaminated site based on normalization geostatistical technologies.

    Science.gov (United States)

    Liu, Geng; Niu, Junjie; Zhang, Chao; Guo, Guanlin

    2015-12-01

    Data distribution is usually skewed severely by the presence of hot spots in contaminated sites. This causes difficulties for accurate geostatistical data transformation. Three types of typical normal distribution transformation methods termed the normal score, Johnson, and Box-Cox transformations were applied to compare the effects of spatial interpolation with normal distribution transformation data of benzo(b)fluoranthene in a large-scale coking plant-contaminated site in north China. Three normal transformation methods decreased the skewness and kurtosis of the benzo(b)fluoranthene, and all the transformed data passed the Kolmogorov-Smirnov test threshold. Cross validation showed that Johnson ordinary kriging has a minimum root-mean-square error of 1.17 and a mean error of 0.19, which was more accurate than the other two models. The area with fewer sampling points and that with high levels of contamination showed the largest prediction standard errors based on the Johnson ordinary kriging prediction map. We introduce an ideal normal transformation method prior to geostatistical estimation for severely skewed data, which enhances the reliability of risk estimation and improves the accuracy for determination of remediation boundaries.

  5. People Detection Based on Spatial Mapping of Friendliness and Floor Boundary Points for a Mobile Navigation Robot

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Tasaki

    2011-01-01

    Full Text Available Navigation robots must single out partners requiring navigation and move in the cluttered environment where people walk around. Developing such robots requires two different people detections: detecting partners and detecting all moving people around the robots. For detecting partners, we design divided spaces based on the spatial relationships and sensing ranges. Mapping the friendliness of each divided space based on the stimulus from the multiple sensors to detect people calling robots positively, robots detect partners on the highest friendliness space. For detecting moving people, we regard objects’ floor boundary points in an omnidirectional image as obstacles. We classify obstacles as moving people by comparing movement of each point with robot movement using odometry data, dynamically changing thresholds to detect. Our robot detected 95.0% of partners while it stands by and interacts with people and detected 85.0% of moving people while robot moves, which was four times higher than previous methods did.

  6. A hierarchical model for estimating the spatial distribution and abundance of animals detected by continuous-time recorders.

    Directory of Open Access Journals (Sweden)

    Robert M Dorazio

    Full Text Available Several spatial capture-recapture (SCR models have been developed to estimate animal abundance by analyzing the detections of individuals in a spatial array of traps. Most of these models do not use the actual dates and times of detection, even though this information is readily available when using continuous-time recorders, such as microphones or motion-activated cameras. Instead most SCR models either partition the period of trap operation into a set of subjectively chosen discrete intervals and ignore multiple detections of the same individual within each interval, or they simply use the frequency of detections during the period of trap operation and ignore the observed times of detection. Both practices make inefficient use of potentially important information in the data.We developed a hierarchical SCR model to estimate the spatial distribution and abundance of animals detected with continuous-time recorders. Our model includes two kinds of point processes: a spatial process to specify the distribution of latent activity centers of individuals within the region of sampling and a temporal process to specify temporal patterns in the detections of individuals. We illustrated this SCR model by analyzing spatial and temporal patterns evident in the camera-trap detections of tigers living in and around the Nagarahole Tiger Reserve in India. We also conducted a simulation study to examine the performance of our model when analyzing data sets of greater complexity than the tiger data.Our approach provides three important benefits: First, it exploits all of the information in SCR data obtained using continuous-time recorders. Second, it is sufficiently versatile to allow the effects of both space use and behavior of animals to be specified as functions of covariates that vary over space and time. Third, it allows both the spatial distribution and abundance of individuals to be estimated, effectively providing a species distribution model, even in

  7. Detecting spatial patterns with the cumulant function – Part 1: The theory

    Directory of Open Access Journals (Sweden)

    P. Naveau

    2008-02-01

    Full Text Available In climate studies, detecting spatial patterns that largely deviate from the sample mean still remains a statistical challenge. Although a Principal Component Analysis (PCA, or equivalently a Empirical Orthogonal Functions (EOF decomposition, is often applied for this purpose, it provides meaningful results only if the underlying multivariate distribution is Gaussian. Indeed, PCA is based on optimizing second order moments, and the covariance matrix captures the full dependence structure of multivariate Gaussian vectors. Whenever the application at hand can not satisfy this normality hypothesis (e.g. precipitation data, alternatives and/or improvements to PCA have to be developed and studied. To go beyond this second order statistics constraint, that limits the applicability of the PCA, we take advantage of the cumulant function that can produce higher order moments information. The cumulant function, well-known in the statistical literature, allows us to propose a new, simple and fast procedure to identify spatial patterns for non-Gaussian data. Our algorithm consists in maximizing the cumulant function. Three families of multivariate random vectors, for which explicit computations are obtained, are implemented to illustrate our approach. In addition, we show that our algorithm corresponds to selecting the directions along which projected data display the largest spread over the marginal probability density tails.

  8. Using demographic characteristics of populations to detect spatial fragmentation following suspected ebola outbreaks in great apes.

    Science.gov (United States)

    Genton, Céline; Cristescu, Romane; Gatti, Sylvain; Levréro, Florence; Bigot, Elodie; Motsch, Peggy; Le Gouar, Pascaline; Pierre, Jean-Sébastien; Ménard, Nelly

    2017-09-01

    Demographic crashes due to emerging diseases can contribute to population fragmentation and increase extinction risk of small populations. Ebola outbreaks in 2002-2004 are suspected to have caused a decline of more than 80% in some Western lowland gorilla (Gorilla gorilla gorilla) populations. We investigated whether demographic indicators of this event allowed for the detection of spatial fragmentation in gorilla populations. We collected demographic data from two neighbouring populations: the Lokoué population, suspected to have been affected by an Ebola outbreak (followed from 2001 to 2014), and the Romani population, of unknown demographic status before Ebola outbreaks (followed from 2005 to 2014). Ten years after the outbreak, the Lokoué population is slowly recovering and the short-term demographic indicators of a population crash were no longer detectable. The Lokoué population has not experienced any additional demographic perturbation over the past decade. The Romani population did not show any of the demographic indicators of a population crash over the past decade. Its demographic structure remained similar to that of unaffected populations. Our results highlighted that the Ebola disease could contribute to fragmentation of gorilla populations due to the spatially heterogeneous impact of its outbreaks. The demographic structure of populations (i.e., age-sex and group structure) can be useful indicators of a possible occurrence of recent Ebola outbreaks in populations without known history, and may be more broadly used in other emerging disease/species systems. Longitudinal data are critical to our understanding of the impact of emerging diseases on wild populations and their conservation. © 2017 Wiley Periodicals, Inc.

  9. Detection of DNA from Leishmania (Viannia: accuracy of polymerase chain reaction for the diagnosis of cutaneous leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Herintha Coeto Neitzke-Abreu

    Full Text Available Cutaneous leishmaniasis (CL can occur in skin and mucosa, causing disfiguring lesions. The laboratory diagnosis of CL involves immunological methods and optical detection of the parasite, al of which have limitations. There is a need for more effective diagnostic methods for CL which wil allow treatment to be initiated more promptly in order to help prevent the development of severe forms of mucosal disease, and to estimate the prognosis of the infection. The polymerase chain reaction (PCR has been widely used to diagnose CL, because of its higher sensitivity. This study estimated the accuracy and compared PCRs of samples from lesion scarification (PCR-L and blood sample-enriched leukocytes (PCR-B with three conventional diagnostic techniques: parasite direct search (DS, Montenegro skin test (MST, and indirect immunofluorescence reaction (IIF. The study included 276 patients under suspicion of CL. We conducted a cross-sectional study, in which patients were selected by convenience sampling. We used MP3H/MP1L primers to generate a Leishmania (Viannia (minicircle kDNA fragment of 70-bp. Of 106 patients with CL, 83.87%, 51.67%, 64.52%, 85.71%, or 96.10% tested positive by PCR-L, PCR-B, DS, IIF, or MST, respectively. Five patients tested positive only by PCR-L, and two other patients only by PCR-B. PCR-L is indicated for use in patients with chronic lesions or Leishmania reinfection, which may progress to mucosal lesion. PCR-B is indicated for use in patients with negative results in conventional tests or for patients with no apparent lesion. PCR is not only useful in diagnosing CL but also helps to identify the infecting species.

  10. Accuracy of non-invasive 13C-urea breath test compared to invasive tests for helicobacter pylori detection

    International Nuclear Information System (INIS)

    Bilal, R.; Khaar, B.; Omar, M.; Qureshi, T.Z.; Ahmed, T.; Latif, Z.; Jaffery, I.; Omar, M.

    2007-01-01

    To compare the sensitivity, specificity and Positive Predictive Value (PPV) of histology, Campylobacter-Like Organism (CLO) test, culture and 13C-Urea Breath Test (UBT) for the diagnosis of Helicobacter pylori infection. District Headquarter Hospital, Rawalpindi, Military Hospital, Rawalpindi and Pakistan Institute of Science and Technology (PINSTECH), Nilore, Islamabad from June 2002 to 2003. Three mucosal biopsy specimens were obtained during endoscopy of 90 symptomatic patients. Histology, CLO test and culture were performed on these specimens. Breath samples for 13C-UBT were collected and sent to RIAD, PINSTECH on the same day for isotope ratio mass spectrometry. For analysis purpose, each of the tests was fixed as the gold standard in turn and the others were then compared against it. In addition, any two as well as any three positive tests were then set as the gold standard and the other tests compared against them to calculate the sensitivity, specificity, accuracy and PPV of other tests. Urea breath test had the highest sensitivity, ranging from 95 to 100%, against all the gold standards with specificity ranging from 55 to 100%, whereas the sensitivity of histological examination was around 98% but it had comparatively lower specificity (49-89%). The CLO test had a sensitivity range of 86-100% and specificity of 67-100%. Culture had the minimum sensitivity (59-70%) but had highest specificity (96-100%) against all the gold standards. Age and gender had no effect on p-value of each test or in combination. The urea breath test has shown the highest ability to detect the organism with 95-100% sensitivity in symptomatic individuals and specificity, which is comparable to other tests. (author)

  11. Low Accuracy of Computed Tomography and Positron Emission Tomography to Detect Lung and Lymph Node Metastases of Colorectal Cancer.

    Science.gov (United States)

    Guerrera, Francesco; Renaud, Stéphane; Schaeffer, Mickaël; Nigra, Victor; Solidoro, Paolo; Santelmo, Nicola; Filosso, Pier Luigi; Falcoz, Pierre-Emmanuel; Ruffini, Enrico; Oliaro, Alberto; Massard, Gilbert

    2017-10-01

    Minimally invasive surgery, stereotactic radiotherapy, and radiofrequency ablation are commonly proposed in the case of pulmonary colorectal-metastasis as alternatives to conventional open surgery. Preoperative imaging assessment by computed tomography (CT) scan and fluorodeoxyglucose positron emission tomography (FDG-PET) are critical to guide oncologic radical treatment. Our aim was to investigate the accuracy of CT and FDG-PET for the evaluation of the number of pulmonary colorectal metastases and thoracic lymph nodal involvement (LNI). Patients who underwent lung surgical resection for pulmonary colorectal metastases from 2004 to 2014 were analyzed. Concordance between histology, CT scan, and FDG-PET findings were assessed. Data of 521 patients were analyzed. Of those, FDG-PET was performed in 435 (83.5%). A moderate agreement between both CT scan (kappa index: 0.42) and FDG-PET (kappa index: 0.42) findings and the histologically proven number of metastases was observed. The number of histologically proven metastases was correctly discriminated in 61.7% of cases with CT scan and in 61.8% of cases with FDG-PET. Multiple metastases were discovered in 20.9% of clinical single metastasis cases with CT scan, and in 24.4% of those cases with FDG-PET. One hundred fifty patients (29.1%) presented with pathologic LNI. A poor agreement was observed between LNI and CT scan findings (kappa index: 0.02), and a weak agreement was observed concerning LNI and FDG-PET findings (kappa index: 0.39). Computed tomography and FDG-PET have limitations if the objective is to detect all malignant nodules and to discriminate the LNI in cases of pulmonary metastases of colorectal cancer. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Diagnostic accuracy of direct ophthalmoscopy for detection of diabetic retinopathy using fundus photographs as a reference standard.

    Science.gov (United States)

    Ahsan, Shahid; Basit, Abdul; Ahmed, Kazi Rumana; Ali, Liaquat; Shaheen, Fariha; Ulhaque, Muhammad Saif; Fawwad, Asher

    2014-01-01

    To determine the diagnostic accuracy of direct ophthalmoscopy for the presence and severity of diabetic retinopathy (DR) using fundus photographs as a reference standard. Patients with type 2 diabetes attending the outpatient department (OPD) of a tertiary care diabetes center, from October 2009 to March 2010 were recruited in the study after obtaining signed informed consent. Patients with type 1 diabetes and gestational diabetes or having eye problems were excluded. After checking visual acuity, direct ophthalmoscopy of each eye was done by diabetologist, followed by photography of two fields of retina by fundus camera. DR was graded by a retinal specialist, according to International Diabetic Retinopathy Disease Severity Scale. According to severity, patients with DR were grouped into non-sight threatening diabetic retinopathy (NSTDR) and sight threatening diabetic retinopathy (STDR). Sensitivity and specificity of direct ophthalmoscopy for detection of any retinopathy, NSTDR and STDR was calculated. A total of 728 eyes were examined by direct ophthalmoscopy as well as fundus photography. Sensitivity (95% CI) of direct ophthalmoscopy for any retinopathy, NSTDR and STDR was found to be 55.67% (50.58-60.78), 37.63% (32.67-42.59) and 68.25% (63.48-73.02) respectively. Whereas, specificity of direct ophthalmoscopy was found to be 76.78% (72.45-81.11), 71.27% (CI: 66.63-75.91) and 90.0% (86.93-93.07) for any retinopathy, NSTDR and STDR respectively. The sensitivity and specificity of direct ophthalmoscopy performed by the diabetologist for the presence and severity of DR was lower compared to the recommended level of sensitivity and specificity of a screening test of DR. Copyright © 2014 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  13. Temporal Data-Driven Sleep Scheduling and Spatial Data-Driven Anomaly Detection for Clustered Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Gang Li

    2016-09-01

    Full Text Available The spatial–temporal correlation is an important feature of sensor data in wireless sensor networks (WSNs. Most of the existing works based on the spatial–temporal correlation can be divided into two parts: redundancy reduction and anomaly detection. These two parts are pursued separately in existing works. In this work, the combination of temporal data-driven sleep scheduling (TDSS and spatial data-driven anomaly detection is proposed, where TDSS can reduce data redundancy. The TDSS model is inspired by transmission control protocol (TCP congestion control. Based on long and linear cluster structure in the tunnel monitoring system, cooperative TDSS and spatial data-driven anomaly detection are then proposed. To realize synchronous acquisition in the same ring for analyzing the situation of every ring, TDSS is implemented in a cooperative way in the cluster. To keep the precision of sensor data, spatial data-driven anomaly detection based on the spatial correlation and Kriging method is realized to generate an anomaly indicator. The experiment results show that cooperative TDSS can realize non-uniform sensing effectively to reduce the energy consumption. In addition, spatial data-driven anomaly detection is quite significant for maintaining and improving the precision of sensor data.

  14. The diagnostic accuracy of detecting malignant transformation of low-grade glioma using O-(2-[F]fluoroethyl)-l-tyrosine positron emission tomography

    DEFF Research Database (Denmark)

    Bashir, Asma; Brennum, Jannick; Broholm, Helle

    2018-01-01

    OBJECTIVE The diagnostic accuracy of O-(2-[18F]fluoroethyl)-l-tyrosine (FET) PET scanning in detecting the malignant transformation of low-grade gliomas (LGGs) is controversial. In this study, the authors retrospectively assessed the diagnostic potential of FET PET in patients with MRI-suspected ...

  15. A comparison of accuracy and precision of 5 gait-event detection algorithms from motion capture in horses during over ground walk

    DEFF Research Database (Denmark)

    Olsen, Emil; Boye, Jenny Katrine; Pfau, Thilo

    2012-01-01

    and use robust and validated algorithms. It is the objective of this study to compare accuracy (bias) and precision (SD) for five published human and equine motion capture foot-on/off and stance phase detection algorithms during walk. Six horses were walked over 8 seamlessly embedded force plates...... of mass generally provides the most accurate and precise results in walk....

  16. Accuracy of "Modified Checklist for Autism in Toddlers" ("M-CHAT") in Detecting Autism and Other Developmental Disorders in Community Clinics

    Science.gov (United States)

    Toh, Teck-Hock; Tan, Vivian Wee-Yen; Lau, Peter Sie-Teck; Kiyu, Andrew

    2018-01-01

    This study determined the accuracy of "Modified Checklist for Autism in Toddlers" ("M-CHAT") in detecting toddlers with autism spectrum disorder (ASD) and other developmental disorders (DD) in community mother and child health clinics. We analysed 19,297 eligible toddlers (15-36 months) who had "M-CHAT" performed in…

  17. The reliability and accuracy of two methods for proximal caries detection and depth on directly visible proximal surfaces: an in vitro study

    DEFF Research Database (Denmark)

    Ekstrand, K R; Alloza, Alvaro Luna; Promisiero, L

    2011-01-01

    This study aimed to determine the reliability and accuracy of the ICDAS and radiographs in detecting and estimating the depth of proximal lesions on extracted teeth. The lesions were visible to the naked eye. Three trained examiners scored a total of 132 sound/carious proximal surfaces from 106 p...

  18. Clinical accuracy of a PLEX-ID flu device for simultaneous detection and identification of influenza viruses A and B.

    Science.gov (United States)

    Tang, Yi-Wei; Lowery, Kristin S; Valsamakis, Alexandra; Schaefer, Virginia C; Chappell, James D; White-Abell, Jill; Quinn, Criziel D; Li, Haijing; Washington, Cicely A; Cromwell, Jenna; Giamanco, Chantel M; Forman, Michael; Holden, Jeffery; Rothman, Richard E; Parker, Michelle L; Ortenberg, Elaine V; Zhang, Lei; Lin, Yea-Lin; Gaydos, Charlotte A

    2013-01-01

    influenza A virus detection and H1N1-p subtyping. The PLEX-ID Flu assay demonstrated a high level of accuracy for the simultaneous detection and identification of influenza A and B viruses in patient specimens, providing a new laboratory tool for the rapid diagnosis and management of influenza A and B virus infections.

  19. Reliability and Minimum Detectable Change of Temporal-Spatial, Kinematic, and Dynamic Stability Measures during Perturbed Gait.

    Directory of Open Access Journals (Sweden)

    Christopher A Rábago

    Full Text Available Temporal-spatial, kinematic variability, and dynamic stability measures collected during perturbation-based assessment paradigms are often used to identify dysfunction associated with gait instability. However, it remains unclear which measures are most reliable for detecting and tracking responses to perturbations. This study systematically determined the between-session reliability and minimum detectable change values of temporal-spatial, kinematic variability, and dynamic stability measures during three types of perturbed gait. Twenty young healthy adults completed two identical testing sessions two weeks apart, comprised of an unperturbed and three perturbed (cognitive, physical, and visual walking conditions in a virtual reality environment. Within each session, perturbation responses were compared to unperturbed walking using paired t-tests. Between-session reliability and minimum detectable change values were also calculated for each measure and condition. All temporal-spatial, kinematic variability and dynamic stability measures demonstrated fair to excellent between-session reliability. Minimal detectable change values, normalized to mean values ranged from 1-50%. Step width mean and variability measures demonstrated the greatest response to perturbations with excellent between-session reliability and low minimum detectable change values. Orbital stability measures demonstrated specificity to perturbation direction and sensitivity with excellent between-session reliability and low minimum detectable change values. We observed substantially greater between-session reliability and lower minimum detectable change values for local stability measures than previously described which may be the result of averaging across trials within a session and using velocity versus acceleration data for reconstruction of state spaces. Across all perturbation types, temporal-spatial, orbital and local measures were the most reliable measures with the

  20. Forecasting energy consumption of multi-family residential buildings using support vector regression: Investigating the impact of temporal and spatial monitoring granularity on performance accuracy

    International Nuclear Information System (INIS)

    Jain, Rishee K.; Smith, Kevin M.; Culligan, Patricia J.; Taylor, John E.

    2014-01-01

    Highlights: • We develop a building energy forecasting model using support vector regression. • Model is applied to data from a multi-family residential building in New York City. • We extend sensor based energy forecasting to multi-family residential buildings. • We examine the impact temporal and spatial granularity has on model accuracy. • Optimal granularity occurs at the by floor in hourly temporal intervals. - Abstract: Buildings are the dominant source of energy consumption and environmental emissions in urban areas. Therefore, the ability to forecast and characterize building energy consumption is vital to implementing urban energy management and efficiency initiatives required to curb emissions. Advances in smart metering technology have enabled researchers to develop “sensor based” approaches to forecast building energy consumption that necessitate less input data than traditional methods. Sensor-based forecasting utilizes machine learning techniques to infer the complex relationships between consumption and influencing variables (e.g., weather, time of day, previous consumption). While sensor-based forecasting has been studied extensively for commercial buildings, there is a paucity of research applying this data-driven approach to the multi-family residential sector. In this paper, we build a sensor-based forecasting model using Support Vector Regression (SVR), a commonly used machine learning technique, and apply it to an empirical data-set from a multi-family residential building in New York City. We expand our study to examine the impact of temporal (i.e., daily, hourly, 10 min intervals) and spatial (i.e., whole building, by floor, by unit) granularity have on the predictive power of our single-step model. Results indicate that sensor based forecasting models can be extended to multi-family residential buildings and that the optimal monitoring granularity occurs at the by floor level in hourly intervals. In addition to implications for

  1. Data processing of remotely sensed airborne hyperspectral data using the Airborne Processing Library (APL): Geocorrection algorithm descriptions and spatial accuracy assessment

    Science.gov (United States)

    Warren, Mark A.; Taylor, Benjamin H.; Grant, Michael G.; Shutler, Jamie D.

    2014-03-01

    Remote sensing airborne hyperspectral data are routinely used for applications including algorithm development for satellite sensors, environmental monitoring and atmospheric studies. Single flight lines of airborne hyperspectral data are often in the region of tens of gigabytes in size. This means that a single aircraft can collect terabytes of remotely sensed hyperspectral data during a single year. Before these data can be used for scientific analyses, they need to be radiometrically calibrated, synchronised with the aircraft's position and attitude and then geocorrected. To enable efficient processing of these large datasets the UK Airborne Research and Survey Facility has recently developed a software suite, the Airborne Processing Library (APL), for processing airborne hyperspectral data acquired from the Specim AISA Eagle and Hawk instruments. The APL toolbox allows users to radiometrically calibrate, geocorrect, reproject and resample airborne data. Each stage of the toolbox outputs data in the common Band Interleaved Lines (BILs) format, which allows its integration with other standard remote sensing software packages. APL was developed to be user-friendly and suitable for use on a workstation PC as well as for the automated processing of the facility; to this end APL can be used under both Windows and Linux environments on a single desktop machine or through a Grid engine. A graphical user interface also exists. In this paper we describe the Airborne Processing Library software, its algorithms and approach. We present example results from using APL with an AISA Eagle sensor and we assess its spatial accuracy using data from multiple flight lines collected during a campaign in 2008 together with in situ surveyed ground control points.

  2. Localization accuracy of compact binary coalescences detected by the third-generation gravitational-wave detectors and implication for cosmology

    Science.gov (United States)

    Zhao, Wen; Wen, Linqing

    2018-03-01

    using GW sources as independent tools to constrain the Hubble constant H0, the deceleration parameter q0, and the equation-of-state (EoS) of dark energy. We find that, in general, if 10 BNSs or NSBHs at z =0.1 with known redshifts are detected by 3G networks consisting of two ET-like detectors, H0 can be measured with an accuracy of 0.9%. If 1000 face-on BNSs at z <2 are detected with known redshifts, we are able to achieve Δ q0=0.002 for the deceleration parameter, or Δ w0=0.03 and Δ wa=0.2 for EoS of dark energy, respectively.

  3. Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations.

    Science.gov (United States)

    Shokri, Abbas; Eskandarloo, Amir; Norouzi, Marouf; Poorolajal, Jalal; Majidi, Gelareh; Aliyaly, Alireza

    2018-03-01

    This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.

  4. Implications of sensor design for coral reef detection: Upscaling ground hyperspectral imagery in spatial and spectral scales

    Science.gov (United States)

    Caras, Tamir; Hedley, John; Karnieli, Arnon

    2017-12-01

    Remote sensing offers a potential tool for large scale environmental surveying and monitoring. However, remote observations of coral reefs are difficult especially due to the spatial and spectral complexity of the target compared to sensor specifications as well as the environmental implications of the water medium above. The development of sensors is driven by technological advances and the desired products. Currently, spaceborne systems are technologically limited to a choice between high spectral resolution and high spatial resolution, but not both. The current study explores the dilemma of whether future sensor design for marine monitoring should prioritise on improving their spatial or spectral resolution. To address this question, a spatially and spectrally resampled ground-level hyperspectral image was used to test two classification elements: (1) how the tradeoff between spatial and spectral resolutions affects classification; and (2) how a noise reduction by majority filter might improve classification accuracy. The studied reef, in the Gulf of Aqaba (Eilat), Israel, is heterogeneous and complex so the local substrate patches are generally finer than currently available imagery. Therefore, the tested spatial resolution was broadly divided into four scale categories from five millimeters to one meter. Spectral resolution resampling aimed to mimic currently available and forthcoming spaceborne sensors such as (1) Environmental Mapping and Analysis Program (EnMAP) that is characterized by 25 bands of 6.5 nm width; (2) VENμS with 12 narrow bands; and (3) the WorldView series with broadband multispectral resolution. Results suggest that spatial resolution should generally be prioritized for coral reef classification because the finer spatial scale tested (pixel size mind, while the focus in this study was on the technologically limited spaceborne design, aerial sensors may presently provide an opportunity to implement the suggested setup.

  5. A spatial hazard model for cluster detection on continuous indicators of disease: application to somatic cell score.

    Science.gov (United States)

    Gay, Emilie; Senoussi, Rachid; Barnouin, Jacques

    2007-01-01

    Methods for spatial cluster detection dealing with diseases quantified by continuous variables are few, whereas several diseases are better approached by continuous indicators. For example, subclinical mastitis of the dairy cow is evaluated using a continuous marker of udder inflammation, the somatic cell score (SCS). Consequently, this study proposed to analyze spatialized risk and cluster components of herd SCS through a new method based on a spatial hazard model. The dataset included annual SCS for 34 142 French dairy herds for the year 2000, and important SCS risk factors: mean parity, percentage of winter and spring calvings, and herd size. The model allowed the simultaneous estimation of the effects of known risk factors and of potential spatial clusters on SCS, and the mapping of the estimated clusters and their range. Mean parity and winter and spring calvings were significantly associated with subclinical mastitis risk. The model with the presence of 3 clusters was highly significant, and the 3 clusters were attractive, i.e. closeness to cluster center increased the occurrence of high SCS. The three localizations were the following: close to the city of Troyes in the northeast of France; around the city of Limoges in the center-west; and in the southwest close to the city of Tarbes. The semi-parametric method based on spatial hazard modeling applies to continuous variables, and takes account of both risk factors and potential heterogeneity of the background population. This tool allows a quantitative detection but assumes a spatially specified form for clusters.

  6. 68Ga-PSMA PET/CT in Patients with Rising Prostatic-Specific Antigen After Definitive Treatment of Prostate Cancer: Detection Efficacy and Diagnostic accuracy.

    Science.gov (United States)

    Hamed, Maged Abdel Galil; Basha, Mohammad Abd Alkhalik; Ahmed, Hussien; Obaya, Ahmed Ali; Afifi, Amira Hamed Mohamed; Abdelbary, Eman H

    2018-06-20

    68 Ga-prostate-specific membrane antigen-11 ( 68 Ga-PSMA-11) is a recently developed positron emission tomography (PET) tracer that can detect prostate cancer (PC) relapses and metastases with high contrast resolution. The aim of this study was to assess the detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT image in patients with rising prostatic-specific antigen (PSA) after treatment of PC. The present prospective study included 188 patients who exhibited rising of PSA level on a routine follow-up examination after definitive treatment of PC. All patients underwent a 68 Ga-PSMA PET/CT examination. For each patient, we determined the disease stage, the Gleason score, and the maximum standardized uptake value of the local recurrence and extraprostatic metastases. The detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT were established by histopathology and clinical and imaging follow-up as the reference standards. 68 Ga-PSMA PET/CT detected tumour relapse in 165 patients (35 patients had local recurrence, 106 patients had extraprostatic metastases, and 24 patients had combined lesions). The sensitivity, specificity, and accuracy values of 68 Ga-PSMA PET/CT examination in the detection of PC recurrence were 98.8%, 100%, and 98.8%, respectively. 68 Ga-PSMA PET/CT revealed an overall detection rate of 87.8% (165/188) in patients with rising PSA (median of 2.2 ng/mL, and range of 0.01-70 ng/mL). 68 Ga-PSMA PET/CT is a valuable tool for the detection of PC local recurrence or extraprostatic metastases following rising PSA levels after primary definitive therapy and should be incorporated during routine work-up. Copyright © 2018. Published by Elsevier Inc.

  7. INTERSECTION DETECTION BASED ON QUALITATIVE SPATIAL REASONING ON STOPPING POINT CLUSTERS

    Directory of Open Access Journals (Sweden)

    S. Zourlidou

    2016-06-01

    Full Text Available The purpose of this research is to propose and test a method for detecting intersections by analysing collectively acquired trajectories of moving vehicles. Instead of solely relying on the geometric features of the trajectories, such as heading changes, which may indicate turning points and consequently intersections, we extract semantic features of the trajectories in form of sequences of stops and moves. Under this spatiotemporal prism, the extracted semantic information which indicates where vehicles stop can reveal important locations, such as junctions. The advantage of the proposed approach in comparison with existing turning-points oriented approaches is that it can detect intersections even when not all the crossing road segments are sampled and therefore no turning points are observed in the trajectories. The challenge with this approach is that first of all, not all vehicles stop at the same location – thus, the stop-location is blurred along the direction of the road; this, secondly, leads to the effect that nearby junctions can induce similar stop-locations. As a first step, a density-based clustering is applied on the layer of stop observations and clusters of stop events are found. Representative points of the clusters are determined (one per cluster and in a last step the existence of an intersection is clarified based on spatial relational cluster reasoning, with which less informative geospatial clusters, in terms of whether a junction exists and where its centre lies, are transformed in more informative ones. Relational reasoning criteria, based on the relative orientation of the clusters with their adjacent ones are discussed for making sense of the relation that connects them, and finally for forming groups of stop events that belong to the same junction.

  8. The performance of spatially offset Raman spectroscopy for liquid explosive detection

    Science.gov (United States)

    Loeffen, Paul W.; Maskall, Guy; Bonthron, Stuart; Bloomfield, Matthew; Tombling, Craig; Matousek, Pavel

    2016-10-01

    Aviation security requirements adopted in 2014 require liquids to be screened at most airports throughout Europe, North America and Australia. Cobalt's unique Spatially Offset Raman Spectroscopy (SORS™) technology has proven extremely effective at screening liquids, aerosols and gels (LAGS) with extremely low false alarm rates. SORS is compatible with a wide range of containers, including coloured, opaque or clear plastics, glass and paper, as well as duty-free bottles in STEBs (secure tamper-evident bags). Our award-winning Insight range has been specially developed for table-top screening at security checkpoints. Insight systems use our patented SORS technology for rapid and accurate chemical analysis of substances in unopened non-metallic containers. Insight100M™ and the latest member of the range - Insight200M™ - also screen metallic containers. Our unique systems screen liquids, aerosols and gels with the highest detection capability and lowest false alarm rates of any ECAC-approved scanner, with several hundred units already in use at airports including eight of the top ten European hubs. This paper presents an analysis of real performance data for these systems.

  9. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    Energy Technology Data Exchange (ETDEWEB)

    Luboldt, Wolfgang [Multiorgan Screening Foundation, Frankfurt (Germany); University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany); University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg [University Hospital Dresden, Clinic and Policlinic of Nuclear Medicine, Dresden (Germany); Wiedemann, Baerbel [University Hospital Dresden, Institute of Medical Informatics and Biometrics, Dresden (Germany); Wehrmann, Ursula [University Hospital Dresden, Clinic and Policlinic of Surgery, Dresden (Germany); Koch, Arne; Abolmaali, Nasreddin [University Hospital Dresden, Oncoray, Dresden (Germany); Toussaint, Todd; Luboldt, Hans-Joachim [Multiorgan Screening Foundation, Frankfurt (Germany); Middendorp, Markus; Gruenwald, Frank [University Hospital Frankfurt, Department of Nuclear Medicine, Frankfurt (Germany); Aust, Daniela [University Hospital Dresden, Department of Pathology, Dresden (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Radiology, Frankfurt am Main (Germany)

    2010-09-15

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas {>=}10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV{sub max} was {>=}5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV{sub max}. FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV{sub max}{>=} 5 improves the accuracy. (orig.)

  10. Detection of relevant colonic neoplasms with PET/CT: promising accuracy with minimal CT dose and a standardised PET cut-off

    International Nuclear Information System (INIS)

    Luboldt, Wolfgang; Volker, Teresa; Zoephel, Klaus; Kotzerke, Joerg; Wiedemann, Baerbel; Wehrmann, Ursula; Koch, Arne; Abolmaali, Nasreddin; Toussaint, Todd; Luboldt, Hans-Joachim; Middendorp, Markus; Gruenwald, Frank; Aust, Daniela; Vogl, Thomas J.

    2010-01-01

    To determine the performance of FDG-PET/CT in the detection of relevant colorectal neoplasms (adenomas ≥10 mm, with high-grade dysplasia, cancer) in relation to CT dose and contrast administration and to find a PET cut-off. 84 patients, who underwent PET/CT and colonoscopy (n=79)/sigmoidoscopy (n=5) for (79 x 6+5 x 2)=484 colonic segments, were included in a retrospective study. The accuracy of low-dose PET/CT in detecting mass-positive segments was evaluated by ROC analysis by two blinded independent reviewers relative to contrast-enhanced PET/CT. On a per-lesion basis characteristic PET values were tested as cut-offs. Low-dose PET/CT and contrast-enhanced PET/CT provide similar accuracies (area under the curve for the average ROC ratings 0.925 vs. 0.929, respectively). PET demonstrated all carcinomas (n=23) and 83% (30/36) of relevant adenomas. In all carcinomas and adenomas with high-grade dysplasia (n=10) the SUV max was ≥5. This cut-off resulted in a better per-segment sensitivity and negative predictive value (NPV) than the average PET/CT reviews (sensitivity: 89% vs. 82%; NPV: 99% vs. 98%). All other tested cut-offs were inferior to the SUV max . FDG-PET/CT provides promising accuracy for colorectal mass detection. Low dose and lack of iodine contrast in the CT component do not impact the accuracy. The PET cut-off SUV max ≥ 5 improves the accuracy. (orig.)

  11. Detection and Segmentation of Vine Canopy in Ultra-High Spatial Resolution RGB Imagery Obtained from Unmanned Aerial Vehicle (UAV: A Case Study in a Commercial Vineyard

    Directory of Open Access Journals (Sweden)

    Carlos Poblete-Echeverría

    2017-03-01

    Full Text Available The use of Unmanned Aerial Vehicles (UAVs in viticulture permits the capture of aerial Red-Green-Blue (RGB images with an ultra-high spatial resolution. Recent studies have demonstrated that RGB images can be used to monitor spatial variability of vine biophysical parameters. However, for estimating these parameters, accurate and automated segmentation methods are required to extract relevant information from RGB images. Manual segmentation of aerial images is a laborious and time-consuming process. Traditional classification methods have shown satisfactory results in the segmentation of RGB images for diverse applications and surfaces, however, in the case of commercial vineyards, it is necessary to consider some particularities inherent to canopy size in the vertical trellis systems (VSP such as shadow effect and different soil conditions in inter-rows (mixed information of soil and weeds. Therefore, the objective of this study was to compare the performance of four classification methods (K-means, Artificial Neural Networks (ANN, Random Forest (RForest and Spectral Indices (SI to detect canopy in a vineyard trained on VSP. Six flights were carried out from post-flowering to harvest in a commercial vineyard cv. Carménère using a low-cost UAV equipped with a conventional RGB camera. The results show that the ANN and the simple SI method complemented with the Otsu method for thresholding presented the best performance for the detection of the vine canopy with high overall accuracy values for all study days. Spectral indices presented the best performance in the detection of Plant class (Vine canopy with an overall accuracy of around 0.99. However, considering the performance pixel by pixel, the Spectral indices are not able to discriminate between Soil and Shadow class. The best performance in the classification of three classes (Plant, Soil, and Shadow of vineyard RGB images, was obtained when the SI values were used as input data in trained

  12. Non-Linear Detection for Joint Space-Frequency Block Coding and Spatial Multiplexing in OFDM-MIMO Systems

    DEFF Research Database (Denmark)

    Rahman, Imadur Mohamed; Marchetti, Nicola; Fitzek, Frank

    2005-01-01

    (SIC) receiver where the detection is done on subcarrier by sub-carrier basis based on both Zero Forcing (ZF) and Minimum Mean Square Error (MMSE) nulling criterion for the system. In terms of Frame Error Rate (FER), MMSE based SIC receiver performs better than all other receivers compared......In this work, we have analyzed a joint spatial diversity and multiplexing transmission structure for MIMO-OFDM system, where Orthogonal Space-Frequency Block Coding (OSFBC) is used across all spatial multiplexing branches. We have derived a BLAST-like non-linear Successive Interference Cancellation...... in this paper. We have found that a linear two-stage receiver for the proposed system [1] performs very close to the non-linear receiver studied in this work. Finally, we compared the system performance in spatially correlated scenario. It is found that higher amount of spatial correlation at the transmitter...

  13. Accuracy of LightCycler® SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol

    OpenAIRE

    Dark, Paul; Wilson, Claire; Blackwood, Bronagh; McAuley, Danny F.; Perkins, Gavin D.; McMullan, Ronan; Gates, Simon; Warhurst, Geoffrey

    2012-01-01

    Background: There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probebased real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting o...

  14. High Spatial resolution remote sensing for salt marsh change detection on Fire Island National Seashore

    Science.gov (United States)

    Campbell, A.; Wang, Y.

    2017-12-01

    Salt marshes are under increasing pressure due to anthropogenic stressors including sea level rise, nutrient enrichment, herbivory and disturbances. Salt marsh losses risk the important ecosystem services they provide including biodiversity, water filtration, wave attenuation, and carbon sequestration. This study determines salt marsh change on Fire Island National Seashore, a barrier island along the south shore of Long Island, New York. Object-based image analysis was used to classifying Worldview-2, high resolution satellite, and topobathymetric LiDAR. The site was impacted by Hurricane Sandy in October of 2012 causing a breach in the Barrier Island and extensive overwash. In situ training data from vegetation plots were used to train the Random Forest classifier. The object-based Worldview-2 classification achieved an overall classification accuracy of 92.75. Salt marsh change for the study site was determined by comparing the 2015 classification with a 1997 classification. The study found a shift from high marsh to low marsh and a reduction in Phragmites on Fire Island. Vegetation losses were observed along the edge of the marsh and in the marsh interior. The analysis agreed with many of the trends found throughout the region including the reduction of high marsh and decline of salt marsh. The reduction in Phragmites could be due to the species shrinking niche between rising seas and dune vegetation on barrier islands. The complex management issues facing salt marsh across the United States including sea level rise and eutrophication necessitate very high resolution classification and change detection of salt marsh to inform management decisions such as restoration, salt marsh migration, and nutrient inputs.

  15. Improved Accuracy of Myocardial Perfusion SPECT for the Detection of Coronary Artery Disease by Utilizing a Support Vector Machines Algorithm

    Science.gov (United States)

    Arsanjani, Reza; Xu, Yuan; Dey, Damini; Fish, Matthews; Dorbala, Sharmila; Hayes, Sean; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2012-01-01

    We aimed to improve the diagnostic accuracy of automatic myocardial perfusion SPECT (MPS) interpretation analysis for prediction of coronary artery disease (CAD) by integrating several quantitative perfusion and functional variables for non-corrected (NC) data by support vector machines (SVM), a computer method for machine learning. Methods 957 rest/stress 99mtechnetium gated MPS NC studies from 623 consecutive patients with correlating invasive coronary angiography and 334 with low likelihood of CAD (LLK < 5% ) were assessed. Patients with stenosis ≥ 50% in left main or ≥ 70% in all other vessels were considered abnormal. Total perfusion deficit (TPD) was computed automatically. In addition, ischemic changes (ISCH) and ejection fraction changes (EFC) between stress and rest were derived by quantitative software. The SVM was trained using a group of 125 pts (25 LLK, 25 0-, 25 1-, 25 2- and 25 3-vessel CAD) using above quantitative variables and second order polynomial fitting. The remaining patients (N = 832) were categorized based on probability estimates, with CAD defined as (probability estimate ≥ 0.50). The diagnostic accuracy of SVM was also compared to visual segmental scoring by two experienced readers. Results Sensitivity of SVM (84%) was significantly better than ISCH (75%, p < 0.05) and EFC (31%, p < 0.05). Specificity of SVM (88%) was significantly better than that of TPD (78%, p < 0.05) and EFC (77%, p < 0.05). Diagnostic accuracy of SVM (86%) was significantly better than TPD (81%), ISCH (81%), or EFC (46%) (p < 0.05 for all). The Receiver-operator-characteristic area-under-the-curve (ROC-AUC) for SVM (0.92) was significantly better than TPD (0.90), ISCH (0.87), and EFC (0.60) (p < 0.001 for all). Diagnostic accuracy of SVM was comparable to the overall accuracy of both visual readers (85% vs. 84%, p < 0.05). ROC-AUC for SVM (0.92) was significantly better than that of both visual readers (0.87 and 0.88, p < 0.03). Conclusion Computational

  16. Early non-destructive biofouling detection and spatial distribution: Application of oxygen sensing optodes

    KAUST Repository

    Farhat, Nadia; Staal, Marc; Siddiqui, Amber; Borisov, S.M.; Bucs, Szilard; Vrouwenvelder, Johannes S.

    2015-01-01

    The spatial and quantitative information on biological activity will lead to better understanding of the biofouling processes, contributing to the development of more effective biofouling control strategies.

  17. The effects of incidentally learned temporal and spatial predictability on response times and visual fixations during target detection and discrimination.

    Directory of Open Access Journals (Sweden)

    Melissa R Beck

    Full Text Available Responses are quicker to predictable stimuli than if the time and place of appearance is uncertain. Studies that manipulate target predictability often involve overt cues to speed up response times. However, less is known about whether individuals will exhibit faster response times when target predictability is embedded within the inter-trial relationships. The current research examined the combined effects of spatial and temporal target predictability on reaction time (RT and allocation of overt attention in a sustained attention task. Participants responded as quickly as possible to stimuli while their RT and eye movements were measured. Target temporal and spatial predictability were manipulated by altering the number of: 1 different time intervals between a response and the next target; and 2 possible spatial locations of the target. The effects of target predictability on target detection (Experiment 1 and target discrimination (Experiment 2 were tested. For both experiments, shorter RTs as target predictability increased across both space and time were found. In addition, the influences of spatial and temporal target predictability on RT and the overt allocation of attention were task dependent; suggesting that effective orienting of attention relies on both spatial and temporal predictability. These results indicate that stimulus predictability can be increased without overt cues and detected purely through inter-trial relationships over the course of repeated stimulus presentations.

  18. Automated Detection of Geomorphic Features in LiDAR Point Clouds of Various Spatial Density

    Science.gov (United States)

    Dorninger, Peter; Székely, Balázs; Zámolyi, András.; Nothegger, Clemens

    2010-05-01

    considerably varying considerably because of the various base points that were needed to cover the whole landslide. The resulting point spacing is approximately 20 cm. The achievable accuracy was about 10 cm. The airborne data was acquired with mean point densities of 2 points per square-meter. The accuracy of this dataset was about 15 cm. The second testing site is an area of the Leithagebirge in Burgenland, Austria. The data was acquired by an airborne Riegl LMS-Q560 laser scanner mounted on a helicopter. The mean point density was 6-8 points per square with an accuracy better than 10 cm. We applied our processing chain on the datasets individually. First, they were transformed to local reference frames and fine adjustments of the individual scans respectively flight strips were applied. Subsequently, the local regression planes were determined for each point of the point clouds and planar features were extracted by means of the proposed approach. It turned out that even small displacements can be detected if the number of points used for the fit is enough to define a parallel but somewhat displaced plane. Smaller cracks and erosional incisions do not disturb the plane fitting, because mostly they are filtered out as outliers. A comparison of the different campaigns of the Doren site showed exciting matches of the detected geomorphic structures. Although the geomorphic structure of the Leithagebirge differs from the Doren landslide, and the scales of the two studies were also different, reliable results were achieved in both cases. Additionally, the approach turned out to be highly robust against points which were not located on the terrain. Hence, no false positives were determined within the dense vegetation above the terrain, while it was possible to cover the investigated areas completely with reliable planes. In some cases, however, some structures in the tree crowns were also recognized, but these small patches could be very well sorted out from the geomorphically

  19. Diagnostic accuracy of fracture detection in suspected non-accidental injury: the effect of edge enhancement and digital display on observer performance

    Energy Technology Data Exchange (ETDEWEB)

    Offiah, A.C. [Department of Radiology, Great Ormond Street Hospital for Children, London (United Kingdom) and Institute of Child Health, London (United Kingdom)]. E-mail: amaka.offiah@gosh.nhs.uk; Moon, L. [Department of Radiology, Great Ormond Street Hospital for Children, London (United Kingdom); Hall, C.M. [Department of Radiology, Great Ormond Street Hospital for Children, London (United Kingdom); Todd-Pokropek, A. [Department of Medical Physics and Bioengineering, University College London, London (United Kingdom)

    2006-02-15

    AIM: To compare the effect of varying degrees of edge enhancement and method of digital image display on fracture detection in suspected non-accidental injury (NAI). MATERIALS AND METHODS: Fifty radiographs from post-mortem skeletal surveys in 13 children with suspected NAI were selected. Images were obtained using a Fuji 5000R computed radiography system. Hard copies were printed with edge enhancement factors 0, 0.5 and 1.2. Images (edge enhancement 0.5) were also displayed on a 1K{sup 2} monitor. Six observers independently evaluated all 200 images for the presence of abnormality. Observers also scored each image for visualization of soft tissues, visualization of trabecular markings and overall image quality. The paired Student's t-test and location receiver operating curve (ROC) analysis were used to compare quality scores and diagnostic accuracy of each display method. Individual and pooled true-positive rates (sensitivity) were determined. For the purposes of ROC analysis, histology was taken as the gold standard. RESULTS: There was no difference in duration of hard and soft-copy reading sessions (p=0.76). After image manipulation soft-copy radiographs scored significantly better for image quality than hard copy (p<0.0001). Pooled observer sensitivity (at a specificity of 90%) was below 50% for all display methods. Diagnostic accuracy varied significantly between observers. Diagnostic accuracy of individual observers was not affected by display method. CONCLUSION: In suspected NAI, diagnostic accuracy of fracture detection is generally low. Diagnostic accuracy appears to be affected more by observer-related factors than by the method of digital image display.

  20. Screening for Dyslexia in French-Speaking University Students: An Evaluation of the Detection Accuracy of the Alouette Test.

    Science.gov (United States)

    Cavalli, Eddy; Colé, Pascale; Leloup, Gilles; Poracchia-George, Florence; Sprenger-Charolles, Liliane; El Ahmadi, Abdessadek

    Developmental dyslexia is a lifelong impairment affecting 5% to 10% of the population. In French-speaking countries, although a number of standardized tests for dyslexia in children are available, tools suitable to screen for dyslexia in adults are lacking. In this study, we administered the Alouette reading test to a normative sample of 164 French university students without dyslexia and a validation sample of 83 students with dyslexia. The Alouette reading test is designed to screen for dyslexia in children, since it taps skills that are typically deficient in dyslexia (i.e., phonological skills). However, the test's psychometric properties have not previously been available, and it is not standardized for adults. The results showed that, on the Alouette test, dyslexic readers were impaired on measures of accuracy, speed, and efficiency (accuracy/reading time). We also found significant correlations between the Alouette reading efficiency and phonological efficiency scores. Finally, in terms of the Alouette test, speed-accuracy trade-offs were found in both groups, and optimal cutoff scores were determined with receiver operator characteristic curves analysis, yielding excellent discriminatory power, with 83.1% sensitivity and 100% specificity for reading efficiency. Thus, this study supports the Alouette test as a sensitive and specific screening tool for adults with dyslexia.

  1. Effect of harmonicity on the detection of a signal in a complex masker and on spatial release from masking.

    Directory of Open Access Journals (Sweden)

    Astrid Klinge

    Full Text Available The amount of masking of sounds from one source (signals by sounds from a competing source (maskers heavily depends on the sound characteristics of the masker and the signal and on their relative spatial location. Numerous studies investigated the ability to detect a signal in a speech or a noise masker or the effect of spatial separation of signal and masker on the amount of masking, but there is a lack of studies investigating the combined effects of many cues on the masking as is typical for natural listening situations. The current study using free-field listening systematically evaluates the combined effects of harmonicity and inharmonicity cues in multi-tone maskers and cues resulting from spatial separation of target signal and masker on the detection of a pure tone in a multi-tone or a noise masker. A linear binaural processing model was implemented to predict the masked thresholds in order to estimate whether the observed thresholds can be accounted for by energetic masking in the auditory periphery or whether other effects are involved. Thresholds were determined for combinations of two target frequencies (1 and 8 kHz, two spatial configurations (masker and target either co-located or spatially separated by 90 degrees azimuth, and five different masker types (four complex multi-tone stimuli, one noise masker. A spatial separation of target and masker resulted in a release from masking for all masker types. The amount of masking significantly depended on the masker type and frequency range. The various harmonic and inharmonic relations between target and masker or between components of the masker resulted in a complex pattern of increased or decreased masked thresholds in comparison to the predicted energetic masking. The results indicate that harmonicity cues affect the detectability of a tonal target in a complex masker.

  2. Diagnostic accuracy of detection and quantification of HBV-DNA and HCV-RNA using dried blood spot (DBS) samples - a systematic review and meta-analysis.

    Science.gov (United States)

    Lange, Berit; Roberts, Teri; Cohn, Jennifer; Greenman, Jamie; Camp, Johannes; Ishizaki, Azumi; Messac, Luke; Tuaillon, Edouard; van de Perre, Philippe; Pichler, Christine; Denkinger, Claudia M; Easterbrook, Philippa

    2017-11-01

    The detection and quantification of hepatitis B (HBV) DNA and hepatitis C (HCV) RNA in whole blood collected on dried blood spots (DBS) may facilitate access to diagnosis and treatment of HBV and HCV infection in resource-poor settings. We evaluated the diagnostic performance of DBS compared to venous blood samples for detection and quantification of HBV-DNA and HCV-RNA in two systematic reviews and meta-analyses on the diagnostic accuracy of HBV DNA and HCV RNA from DBS compared to venous blood samples. We searched MEDLINE, Embase, Global Health, Web of Science, LILAC and Cochrane library for studies that assessed diagnostic accuracy with DBS. Heterogeneity was assessed and where appropriate pooled estimates of sensitivity and specificity were generated using bivariate analyses with maximum likelihood estimates and 95% confidence intervals. We also conducted a narrative review on the impact of varying storage conditions or different cut-offs for detection from studies that undertook this in a subset of samples. The QUADAS-2 tool was used to assess risk of bias. In the quantitative synthesis for diagnostic accuracy of HBV-DNA using DBS, 521 citations were identified, and 12 studies met the inclusion criteria. Overall quality of studies was rated as low. The pooled estimate of sensitivity and specificity for HBV-DNA was 95% (95% CI: 83-99) and 99% (95% CI: 53-100), respectively. In the two studies that reported on cut-offs and limit of detection (LoD) - one reported a sensitivity of 98% for a cut-off of ≥2000 IU/ml and another reported a LoD of 914 IU/ml using a commercial assay. Varying storage conditions for individual samples did not result in a significant variation of results. In the synthesis for diagnostic accuracy of HCV-RNA using DBS, 15 studies met the inclusion criteria, and this included six additional studies to a previously published review. The pooled sensitivity and specificity was 98% (95% CI:95-99) and 98% (95% CI:95-99.0), respectively

  3. Chromosphere of K giant stars. Geometrical extent and spatial structure detection

    Science.gov (United States)

    Berio, P.; Merle, T.; Thévenin, F.; Bonneau, D.; Mourard, D.; Chesneau, O.; Delaa, O.; Ligi, R.; Nardetto, N.; Perraut, K.; Pichon, B.; Stee, P.; Tallon-Bosc, I.; Clausse, J. M.; Spang, A.; McAlister, H.; ten Brummelaar, T.; Sturmann, J.; Sturmann, L.; Turner, N.; Farrington, C.; Goldfinger, P. J.

    2011-11-01

    Context. Interferometers provide accurate diameter measurements of stars by analyzing both the continuum and the lines formed in photospheres and chromospheres. Tests of the geometrical extent of the chromospheres are therefore possible by comparing the estimated radius in the continuum of the photosphere and the estimated radii in chromospheric lines. Aims: We aim to constrain the geometrical extent of the chromosphere of non-binary K giant stars and detect any spatial structures in the chromosphere. Methods: We performed observations with the CHARA interferometer and the VEGA beam combiner at optical wavelengths. We observed seven non-binary K giant stars (β and η Cet, δ Crt, ρ Boo, β Oph, 109 Her, and ι Cep). We measured the ratio of the radii of the photosphere to the chromosphere using the interferometric measurements in the Hα and the Ca II infrared triplet line cores. For β Cet, spectro-interferometric observations are compared to a non-local thermal equilibrium (NLTE) semi-empirical model atmosphere including a chromosphere. The NLTE computations provide line intensities and contribution functions that indicate the relative locations where the line cores are formed and can constrain the size of the limb-darkened disk of the stars with chromospheres. We measured the angular diameter of seven K giant stars and deduced their fundamental parameters: effective temperatures, radii, luminosities, and masses. We determined the geometrical extent of the chromosphere for four giant stars (β and η Cet, δ Crt and ρ Boo). Results: The chromosphere extents obtained range between 16% to 47% of the stellar radius. The NLTE computations confirm that the Ca II/849 nm line core is deeper in the chromosphere of β Cet than either of the Ca II/854 nm and Ca II/866 nm line cores. We present a modified version of a semi-empirical model atmosphere derived by fitting the Ca II triplet line cores of this star. In four of our targets, we also detect the signature of a

  4. The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

    International Nuclear Information System (INIS)

    Kajan, Zahra Dalili; Davalloo, Reza Tayefeh; Tavangar, Mayam; Valizade, Fatemeh

    2015-01-01

    Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying 'Sharpening 2' and 'Noise Reduction' processing options to the original images; (2) applying the 'Magnification 1:3' option to the image obtained in the first step; (3) enhancing the original images by using the 'Diagonal/' option; (4) reviewing the changes brought about by the third step of image processing and then, applying 'Magnification 1:3'; (5) applying 'Sharpening UM' to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying 'Magnification 1:3.' Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). This study shows that the application of 'Sharpening UM' along with the 'Magnification 1:3' processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

  5. The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

    Energy Technology Data Exchange (ETDEWEB)

    Kajan, Zahra Dalili; Davalloo, Reza Tayefeh; Tavangar, Mayam; Valizade, Fatemeh [Faculty of Dentistry, Guilan University of Medical Sciences, Rasht (Iran, Islamic Republic of)

    2015-06-15

    Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying 'Sharpening 2' and 'Noise Reduction' processing options to the original images; (2) applying the 'Magnification 1:3' option to the image obtained in the first step; (3) enhancing the original images by using the 'Diagonal/' option; (4) reviewing the changes brought about by the third step of image processing and then, applying 'Magnification 1:3'; (5) applying 'Sharpening UM' to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying 'Magnification 1:3.' Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). This study shows that the application of 'Sharpening UM' along with the 'Magnification 1:3' processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

  6. Right hemisphere dominance during spatial selective attention and target detection occurs outside the dorsal fronto-parietal network

    Science.gov (United States)

    Shulman, Gordon L.; Pope, Daniel L. W.; Astafiev, Serguei V.; McAvoy, Mark P.; Snyder, Abraham Z.; Corbetta, Maurizio

    2010-01-01

    Spatial selective attention is widely considered to be right hemisphere dominant. Previous functional magnetic resonance imaging (fMRI) studies, however, have reported bilateral blood-oxygenation-level-dependent (BOLD) responses in dorsal fronto-parietal regions during anticipatory shifts of attention to a location (Kastner et al., 1999; Corbetta et al., 2000; Hopfinger et al., 2000). Right-lateralized activity has mainly been reported in ventral fronto-parietal regions for shifts of attention to an unattended target stimulus (Arrington et al., 2000; Corbetta et al., 2000). However, clear conclusions cannot be drawn from these studies because hemispheric asymmetries were not assessed using direct voxel-wise comparisons of activity in left and right hemispheres. Here, we used this technique to measure hemispheric asymmetries during shifts of spatial attention evoked by a peripheral cue stimulus and during target detection at the cued location. Stimulus-driven shifts of spatial attention in both visual fields evoked right-hemisphere dominant activity in temporo-parietal junction (TPJ). Target detection at the attended location produced a more widespread right hemisphere dominance in frontal, parietal, and temporal cortex, including the TPJ region asymmetrically activated during shifts of spatial attention. However, hemispheric asymmetries were not observed during either shifts of attention or target detection in the dorsal fronto-parietal regions (anterior precuneus, medial intraparietal sulcus, frontal eye fields) that showed the most robust activations for shifts of attention. Therefore, right hemisphere dominance during stimulus-driven shifts of spatial attention and target detection reflects asymmetries in cortical regions that are largely distinct from the dorsal fronto-parietal network involved in the control of selective attention. PMID:20219998

  7. Detection and Classification of Multiple Objects using an RGB-D Sensor and Linear Spatial Pyramid Matching

    DEFF Research Database (Denmark)

    Dimitriou, Michalis; Kounalakis, Tsampikos; Vidakis, Nikolaos

    2013-01-01

    , connected components detection and filtering approaches, in order to design a complete image processing algorithm for efficient object detection of multiple individual objects in a single scene, even in complex scenes with many objects. Besides, we apply the Linear Spatial Pyramid Matching (LSPM) [1] method......This paper presents a complete system for multiple object detection and classification in a 3D scene using an RGB-D sensor such as the Microsoft Kinect sensor. Successful multiple object detection and classification are crucial features in many 3D computer vision applications. The main goal...... is making machines see and understand objects like humans do. To this goal, the new RGB-D sensors can be utilized since they provide real-time depth map which can be used along with the RGB images for our tasks. In our system we employ effective depth map processing techniques, along with edge detection...

  8. Comparison of the accuracy of Hybrid Capture II and polymerase chain reaction in detecting clinically important cervical dysplasia: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Luu, Hung N; Dahlstrom, Kristina R; Mullen, Patricia Dolan; VonVille, Helena M; Scheurer, Michael E

    2013-01-01

    The effectiveness of screening programs for cervical cancer has benefited from the inclusion of Human papillomavirus (HPV) DNA assays; which assay to choose, however, is not clear based on previous reviews. Our review addressed test accuracy of Hybrid Capture II (HCII) and polymerase chain reaction (PCR) assays based on studies with stronger designs and with more clinically relevant outcomes. We searched OvidMedline, PubMed, and the Cochrane Library for English language studies comparing both tests, published 1985–2012, with cervical dysplasia defined by the Bethesda classification. Meta-analysis provided pooled sensitivity, specificity, and 95% confidence intervals (CIs); meta-regression identified sources of heterogeneity. From 29 reports, we found that the pooled sensitivity and specificity to detect high-grade squamous intraepithelial lesion (HSIL) was higher for HCII than PCR (0.89 [CI: 0.89–0.90] and 0.85 [CI: 0.84–0.86] vs. 0.73 [CI: 0.73–0.74] and 0.62 [CI: 0.62–0.64]). Both assays had higher accuracy to detect cervical dysplasia in Europe than in Asia-Pacific or North America (diagnostic odd ratio – dOR = 4.08 [CI: 1.39–11.91] and 4.56 [CI: 1.86–11.17] for HCII vs. 2.66 [CI: 1.16–6.53] and 3.78 [CI: 1.50–9.51] for PCR) and accuracy to detect HSIL than atypical squamous cells of undetermined significance (ASCUS)/ low-grade squamous intraepithelial lesion (LSIL) (HCII-dOR = 9.04 [CI: 4.12–19.86] and PCR-dOR = 5.60 [CI: 2.87–10.94]). For HCII, using histology as a gold standard results in higher accuracy than using cytology (dOR = 2.87 [CI: 1.31–6.29]). Based on higher test accuracy, our results support the use of HCII in cervical cancer screening programs. The role of HPV type distribution should be explored to determine the worldwide comparability of HPV test accuracy

  9. Influenza detection and prediction algorithms: comparative accuracy trial in Östergötland county, Sweden, 2008-2012.

    Science.gov (United States)

    Spreco, A; Eriksson, O; Dahlström, Ö; Timpka, T

    2017-07-01

    Methods for the detection of influenza epidemics and prediction of their progress have seldom been comparatively evaluated using prospective designs. This study aimed to perform a prospective comparative trial of algorithms for the detection and prediction of increased local influenza activity. Data on clinical influenza diagnoses recorded by physicians and syndromic data from a telenursing service were used. Five detection and three prediction algorithms previously evaluated in public health settings were calibrated and then evaluated over 3 years. When applied on diagnostic data, only detection using the Serfling regression method and prediction using the non-adaptive log-linear regression method showed acceptable performances during winter influenza seasons. For the syndromic data, none of the detection algorithms displayed a satisfactory performance, while non-adaptive log-linear regression was the best performing prediction method. We conclude that evidence was found for that available algorithms for influenza detection and prediction display satisfactory performance when applied on local diagnostic data during winter influenza seasons. When applied on local syndromic data, the evaluated algorithms did not display consistent performance. Further evaluations and research on combination of methods of these types in public health information infrastructures for 'nowcasting' (integrated detection and prediction) of influenza activity are warranted.

  10. Partially hydrolyzed guar gum characterization and sensitive quantification in food matrices by high performance anion exchange chromatography with pulsed amperometric detection--validation using accuracy profile.

    Science.gov (United States)

    Mercier, G; Campargue, C

    2012-11-02

    Interest concerning functional ingredients and especially dietary fibres has been growing in recent years. At the same time, the variety of ingredient accepted as dietary fibres and their mixing at low level in complex matrices have considerably complicated their quantitative analysis by approved AOAC methods. These reasons have led to the specific development of an innovative analytical method performed by high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection (PAD) to detect and quantify partially hydrolyzed guar gum (PHGG) in fruit preparation and dairy matrices. The analytical methodology was divided in two steps which could be deployed separately or in conjunction. The first, consists in a complete characterization of PHGG by size exclusion chromatography (SEC) with multi-angle light scattering and refractive index detection and HPAEC-PAD to determine its physico-chemical properties and galactomannans content, and the second step is the development of a new HPAEC-PAD method for PHGG direct quantification in complex matrices (dairy product). Validation in terms of detection and quantification limits, linearity of the analytical range, average accuracy (recovery, trueness) and average uncertainty were statistically carried out with accuracy profile. Overall, this new chromatographic method has considerably improved the possibility to quantify without fractionation treatment, low level of dietary fibres emerging from specific galactomannans, in complex matrices and many foodstuffs. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries: protocol for a systematic review of diagnostic accuracy.

    Science.gov (United States)

    Wade, Ryckie G; Takwoingi, Yemisi; Wormald, Justin C R; Ridgway, John P; Tanner, Steven; Rankine, James J; Bourke, Grainne

    2018-05-19

    Adult brachial plexus injuries (BPI) are becoming more common. The reconstruction and prognosis of pre-ganglionic injuries (root avulsions) are different to other types of BPI injury. Preoperative magnetic resonance imaging (MRI) is being used to identify root avulsions, but the evidence from studies of its diagnostic accuracy are conflicting. Therefore, a systematic review is needed to address uncertainty about the accuracy of MRI and to guide future research. We will conduct a systematic search of electronic databases alongside reference tracking. We will include studies of adults with traumatic BPI which report the accuracy of preoperative MRI (index test) against surgical exploration of the roots of the brachial plexus (reference standard) for detecting either of the two target conditions (any root avulsion or any pseudomeningocoele as a surrogate marker of root avulsion). We will exclude case reports, articles considering bilateral injuries and studies where the number of true positives, false positives, false negatives and true negatives cannot be derived. The methodological quality of the included studies will be assessed using a tailored version of the QUADAS-2 tool. Where possible, a bivariate model will be used for meta-analysis to obtain summary sensitivities and specificities for both target conditions. We will investigate heterogeneity in the performance of MRI according to field strength and the risk of bias if data permits. This review will summarise the current diagnostic accuracy of MRI for adult BPI, identify shortcomings and gaps in the literature and so help to guide future research. PROSPERO CRD42016049702 .

  12. Role of MRI in detecting involvement of the uterine internal os in uterine cervical cancer: Systematic review of diagnostic test accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Boer, Peter de, E-mail: p.deboer@amc.uva.nl [Department of Radiation Oncology, Academic Medical Centre (AMC), University of Amsterdam (UvA), Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Adam, Judit A. [Department of Radiology, AMC, UvA (Netherlands); Department of Nuclear Medicine, AMC, UvA (Netherlands); Buist, Marrije R. [Department of Gynaecology and Obstetrics, AMC, UvA (Netherlands); Vijver, Marc J. van de [Department of Pathology, AMC, UvA (Netherlands); Rasch, Coen R. [Department of Radiation Oncology, Academic Medical Centre (AMC), University of Amsterdam (UvA), Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Stoker, Jaap; Bipat, Shandra [Department of Radiology, AMC, UvA (Netherlands); Stalpers, Lukas J.A. [Department of Radiation Oncology, Academic Medical Centre (AMC), University of Amsterdam (UvA), Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2013-09-15

    Purpose: In patients with uterine cervical cancer, pretreatment recognition of uterine extension is crucial in treatment decision-making for fertility-sparing surgery and for target delineation in radiotherapy. Although MRI is generally considered the most reliable method, its value for detecting involvement of the uterine internal os is unclear. Methods: Medline, Embase and Cochrane databases were systematically searched (January 1997–December 2012) for MRI studies that measured the accuracy of involvement of the uterine internal os compared to histopathology as reference standard in patients with uterine cervical cancer. Data were assessed using the QUADAS tool. Accuracy concerned either involvement (yes/no) of the uterine internal os, or measuring invasion distance toward the uterine corpus. Results: Two retrospective and two prospective studies described 366 patients diagnosed with uterine cervical cancer FIGO stage IIB or below, in whom 64 (17%) had uterine internal os involvement. For three studies the summary estimates of specificity, sensitivity, negative predictive value (NPV), positive predictive value (PPV), and accuracy were 91%, 97%, 99%, 79% and 95%, respectively; one study had an area under the curve (AUC) of 0.8. Conclusion: MRI has a high level of accuracy; however, data are limited and for validation a large prospective study is needed that compares actual measurements on MRI with histopathological examination.

  13. The accuracy of chest radiographs in the detection of congenital heart disease and in the diagnosis of specific congenital cardiac lesions

    International Nuclear Information System (INIS)

    Laya, Bernard F.; Goske, Marilyn J.; Morrison, Stuart; Reid, Janet R.; Swischuck, Leonard; Ey, Elizabeth H.; Murphy, Daniel J.; Lieber, Michael; Obuchowski, Nancy

    2006-01-01

    Congenital heart disease (CHD) is a significant cause of morbidity and mortality in pediatric patients. Traditional teaching holds that specific types of CHD can be diagnosed on the chest radiograph (CXR) through pattern recognition. To determine the accuracy of radiologists in detecting CHD on the CXR. This study was a blinded retrospective review of chest radiographs from 281 patients (<12 years) by five pediatric radiologists from three institutions. Thirteen groups were evaluated that included 12 categories of CHD and a control group of patients without heart disease. Radiographs were assessed for heart size, heart and mediastinal shape and vascularity. Clinical information, angiography, echocardiograms and surgery were used as the gold standard for definitive diagnosis. The average accuracy of the five readers in distinguishing normal from CHD patients was 78% (range of 72% to 82%). The overall measure of accuracy in distinguishing specific congenital cardiac lesions among 13 groups of patients was 71% (range of 63% to 79%). CXR alone is not diagnostic of specific cardiac lesions, with a low accuracy of only 71%. We believe that less emphasis should be placed on the use of radiographs alone in diagnosing specific congenital cardiac lesions. (orig.)

  14. Accuracy of optical spectroscopy for the detection of cervical intraepithelial neoplasia without colposcopic tissue information; a step toward automation for low resource settings.

    Science.gov (United States)

    Yamal, Jose-Miguel; Zewdie, Getie A; Cox, Dennis D; Atkinson, E Neely; Cantor, Scott B; MacAulay, Calum; Davies, Kalatu; Adewole, Isaac; Buys, Timon P H; Follen, Michele

    2012-04-01

    Optical spectroscopy has been proposed as an accurate and low-cost alternative for detection of cervical intraepithelial neoplasia. We previously published an algorithm using optical spectroscopy as an adjunct to colposcopy and found good accuracy (sensitivity=1.00 [95% confidence interval (CI)=0.92 to 1.00], specificity=0.71 [95% CI=0.62 to 0.79]). Those results used measurements taken by expert colposcopists as well as the colposcopy diagnosis. In this study, we trained and tested an algorithm for the detection of cervical intraepithelial neoplasia (i.e., identifying those patients who had histology reading CIN 2 or worse) that did not include the colposcopic diagnosis. Furthermore, we explored the interaction between spectroscopy and colposcopy, examining the importance of probe placement expertise. The colposcopic diagnosis-independent spectroscopy algorithm had a sensitivity of 0.98 (95% CI=0.89 to 1.00) and a specificity of 0.62 (95% CI=0.52 to 0.71). The difference in the partial area under the ROC curves between spectroscopy with and without the colposcopic diagnosis was statistically significant at the patient level (p=0.05) but not the site level (p=0.13). The results suggest that the device has high accuracy over a wide range of provider accuracy and hence could plausibly be implemented by providers with limited training.

  15. Matrix effect on the detection limit and accuracy in total reflection X-ray fluorescence analysis of trace elements in environmental and biological samples

    International Nuclear Information System (INIS)

    Karjou, J.

    2007-01-01

    The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH 4 NO 3 . It was found that high matrix concentration, i.e. 0.1-10% NH 4 NO 3 , had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0-0.1% NH 4 NO 3 . The effect of soil and blood sample masses on the detection limit was also studied. The results showed decreasing the detection limit (in concentration unit, μg/g) with increasing the sample mass. However, the detection limit increased (in mass unit, ng) with increasing sample mass. The optimal blood sample mass of ca. 200 μg was sufficient to improve the detection limit of Se determination by total reflection X-ray fluorescence. The capability of total reflection X-ray fluorescence to analyze different kinds of samples was discussed with respect to the accuracy and detection limits based on certified and reference materials. Direct analysis of unknown water samples from several sources was also presented in this work

  16. Object-Based Change Detection in Urban Areas from High Spatial Resolution Images Based on Multiple Features and Ensemble Learning

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2018-02-01

    Full Text Available To improve the accuracy of change detection in urban areas using bi-temporal high-resolution remote sensing images, a novel object-based change detection scheme combining multiple features and ensemble learning is proposed in this paper. Image segmentation is conducted to determine the objects in bi-temporal images separately. Subsequently, three kinds of object features, i.e., spectral, shape and texture, are extracted. Using the image differencing process, a difference image is generated and used as the input for nonlinear supervised classifiers, including k-nearest neighbor, support vector machine, extreme learning machine and random forest. Finally, the results of multiple classifiers are integrated using an ensemble rule called weighted voting to generate the final change detection result. Experimental results of two pairs of real high-resolution remote sensing datasets demonstrate that the proposed approach outperforms the traditional methods in terms of overall accuracy and generates change detection maps with a higher number of homogeneous regions in urban areas. Moreover, the influences of segmentation scale and the feature selection strategy on the change detection performance are also analyzed and discussed.

  17. Spatial recurrence analysis: A sensitive and fast detection tool in digital mammography

    International Nuclear Information System (INIS)

    Prado, T. L.; Galuzio, P. P.; Lopes, S. R.; Viana, R. L.

    2014-01-01

    Efficient diagnostics of breast cancer requires fast digital mammographic image processing. Many breast lesions, both benign and malignant, are barely visible to the untrained eye and requires accurate and reliable methods of image processing. We propose a new method of digital mammographic image analysis that meets both needs. It uses the concept of spatial recurrence as the basis of a spatial recurrence quantification analysis, which is the spatial extension of the well-known time recurrence analysis. The recurrence-based quantifiers are able to evidence breast lesions in a way as good as the best standard image processing methods available, but with a better control over the spurious fragments in the image

  18. Diagnostic Accuracy of the Work Functioning Impairment Scale (WFun): A Method to Detect Workers Who Have Health Problems Affecting their Work and to Evaluate Fitness for Work.

    Science.gov (United States)

    Nagata, Tomohisa; Fujino, Yoshihisa; Saito, Kumi; Uehara, Masamichi; Oyama, Ichiro; Izumi, Hiroyuki; Kubo, Tatsuhiko

    2017-06-01

    This study evaluated the diagnostic accuracy of the Work Functioning Impairment Scale (WFun), a questionnaire to detect workers with health problems which affect their work, using an assessment by an occupational health nurse as objective standard. The WFun was completed by 294 employees. The nurse interviewed to assess 1) health problems; 2) effects of health on their work; necessity for 3) treatment, 4) health care instruction, and 5) consideration of job accommodation. The odds ratio in the high work functioning impairment group compared with the low was highly statistically significant with 9.05, 10.26, 5.77, 9.37, and 14.70, respectively. The WFun demonstrated the high detectability with an area under the receiver operating characteristic of 0.75, 0.81, 0.72, 0.79, and 0.83, respectively. This study suggests that the WFun is useful in detecting those who have health problems affecting their work.

  19. Probe-level linear model fitting and mixture modeling results in high accuracy detection of differential gene expression

    Directory of Open Access Journals (Sweden)

    Lemieux Sébastien

    2006-08-01

    Full Text Available Abstract Background The identification of differentially expressed genes (DEGs from Affymetrix GeneChips arrays is currently done by first computing expression levels from the low-level probe intensities, then deriving significance by comparing these expression levels between conditions. The proposed PL-LM (Probe-Level Linear Model method implements a linear model applied on the probe-level data to directly estimate the treatment effect. A finite mixture of Gaussian components is then used to identify DEGs using the coefficients estimated by the linear model. This approach can readily be applied to experimental design with or without replication. Results On a wholly defined dataset, the PL-LM method was able to identify 75% of the differentially expressed genes within 10% of false positives. This accuracy was achieved both using the three replicates per conditions available in the dataset and using only one replicate per condition. Conclusion The method achieves, on this dataset, a higher accuracy than the best set of tools identified by the authors of the dataset, and does so using only one replicate per condition.

  20. Diagnoses accuracy in the detection of abnormalities in the thorax x-ray: Teleradiology vs. conventional radiology

    International Nuclear Information System (INIS)

    Moron, Fanny Emilia; Melendez, Patricia; Martinez, Carlos Eli

    1998-01-01

    Background: introduction of teleradiology in Colombia is very recent and its operative characteristics and reliability are unknown. Objective: to evaluate intra and interobserver concordance in the interpretation of digitized chest x-ray films and to compare diagnostic Accuracy of teleradiology and film screen interpretation. Design: cross-sectional study for evaluation or concordance and operative characteristics of a diagnostic test. Patients and methods: convenience sample of 40 chest films. Independent lecture of digitized images for each radiologist to evaluate interobserver concordance: second lecture of digitized images for evaluation of intraobserver concordance. Generation of a gold standard diagnosis with a consensus interpretation of film screens, comparison of operative characteristics of teleradiology and conventional interpretation, using as a reference the gold standard (consensus lectures) and comparison of diagnostic precision using receiver operating characteristics curves (ROC curves). Results: agreements and concordance were significant higher than expected in both evaluations (inter and intraobserver). Sensitivity of teleradiology was similar to sensitivity of film screen interpretation and areas under ROC curves were not statistically different. Conclusions: concordance in the interpretation of chest radiological studies are significant in a teleradiology system and diagnostic utility of teleradiology is the same as conventional film screen interpretation. Accuracy and reliability of teleradiology are optimal

  1. Diagnostic accuracy of DXA compared to conventional spine radiographs for the detection of vertebral fractures in children

    International Nuclear Information System (INIS)

    Adiotomre, E.; Summers, L.; Digby, M.; Allison, A.; Walters, S.J.; Broadley, P.; Lang, I.; Morrison, G.; Bishop, N.; Arundel, P.; Offiah, A.C.

    2017-01-01

    In children, radiography is performed to diagnose vertebral fractures and dual energy x-ray absorptiometry (DXA) to assess bone density. In adults, DXA assesses both. We aimed to establish whether DXA can replace spine radiographs in assessment of paediatric vertebral fractures. Prospectively, lateral spine radiographs and lateral spine DXA of 250 children performed on the same day were independently scored by three radiologists using the simplified algorithm-based qualitative technique and blinded to results of the other modality. Consensus radiograph read and second read of 100 random images were performed. Diagnostic accuracy, inter/intraobserver and intermodality agreements, patient/carer experience and radiation dose were assessed. Average sensitivity and specificity (95 % confidence interval) in diagnosing one or more vertebral fractures requiring treatment was 70 % (58-82 %) and 97 % (94-100 %) respectively for DXA and 74 % (55-93 %) and 96 % (95-98 %) for radiographs. Fleiss' kappa for interobserver and average kappa for intraobserver reliability were 0.371 and 0.631 respectively for DXA and 0.418 and 0.621 for radiographs. Average effective dose was 41.9 μSv for DXA and 232.7 μSv for radiographs. Image quality was similar. Given comparable image quality and non-inferior diagnostic accuracy, lateral spine DXA should replace conventional radiographs for assessment of vertebral fractures in children. (orig.)

  2. Diagnostic accuracy of DXA compared to conventional spine radiographs for the detection of vertebral fractures in children

    Energy Technology Data Exchange (ETDEWEB)

    Adiotomre, E. [Sheffield Teaching Hospitals NHS Foundation Trust, Radiology Department, Sheffield, South Yorkshire (United Kingdom); Sheffield Children' s Hospital NHS Foundation Trust, Radiology Department, Sheffield, South Yorkshire (United Kingdom); Summers, L.; Digby, M. [University of Sheffield, Sheffield Medical School, Sheffield, South Yorkshire (United Kingdom); Allison, A.; Walters, S.J. [University of Sheffield, School of Health and Related Research, Sheffield, South Yorkshire (United Kingdom); Broadley, P.; Lang, I. [Sheffield Children' s Hospital NHS Foundation Trust, Radiology Department, Sheffield, South Yorkshire (United Kingdom); Morrison, G. [Sheffield Teaching Hospitals NHS Foundation Trust, Medical Physics, Sheffield, South Yorkshire (United Kingdom); Bishop, N.; Arundel, P. [University of Sheffield, Academic Unit of Child Health, Sheffield, South Yorkshire (United Kingdom); Offiah, A.C. [Sheffield Children' s Hospital NHS Foundation Trust, Radiology Department, Sheffield, South Yorkshire (United Kingdom); University of Sheffield, Academic Unit of Child Health, Sheffield, South Yorkshire (United Kingdom)

    2017-05-15

    In children, radiography is performed to diagnose vertebral fractures and dual energy x-ray absorptiometry (DXA) to assess bone density. In adults, DXA assesses both. We aimed to establish whether DXA can replace spine radiographs in assessment of paediatric vertebral fractures. Prospectively, lateral spine radiographs and lateral spine DXA of 250 children performed on the same day were independently scored by three radiologists using the simplified algorithm-based qualitative technique and blinded to results of the other modality. Consensus radiograph read and second read of 100 random images were performed. Diagnostic accuracy, inter/intraobserver and intermodality agreements, patient/carer experience and radiation dose were assessed. Average sensitivity and specificity (95 % confidence interval) in diagnosing one or more vertebral fractures requiring treatment was 70 % (58-82 %) and 97 % (94-100 %) respectively for DXA and 74 % (55-93 %) and 96 % (95-98 %) for radiographs. Fleiss' kappa for interobserver and average kappa for intraobserver reliability were 0.371 and 0.631 respectively for DXA and 0.418 and 0.621 for radiographs. Average effective dose was 41.9 μSv for DXA and 232.7 μSv for radiographs. Image quality was similar. Given comparable image quality and non-inferior diagnostic accuracy, lateral spine DXA should replace conventional radiographs for assessment of vertebral fractures in children. (orig.)

  3. Quantifying Forest Spatial Pattern Trends at Multiple Extents: An Approach to Detect Significant Changes at Different Scales

    Directory of Open Access Journals (Sweden)

    Ludovico Frate

    2014-09-01

    Full Text Available We propose a procedure to detect significant changes in forest spatial patterns and relevant scales. Our approach consists of four sequential steps. First, based on a series of multi-temporal forest maps, a set of geographic windows of increasing extents are extracted. Second, for each extent and date, specific stochastic simulations that replicate real-world spatial pattern characteristics are run. Third, by computing pattern metrics on both simulated and real maps, their empirical distributions and confidence intervals are derived. Finally, multi-temporal scalograms are built for each metric. Based on cover maps (1954, 2011 with a resolution of 10 m we analyze forest pattern changes in a central Apennines (Italy reserve at multiple spatial extents (128, 256 and 512 pixels. We identify three types of multi-temporal scalograms, depending on pattern metric behaviors, describing different dynamics of natural reforestation process. The statistical distribution and variability of pattern metrics at multiple extents offers a new and powerful tool to detect forest variations over time. Similar procedures can (i help to identify significant changes in spatial patterns and provide the bases to relate them to landscape processes; (ii minimize the bias when comparing pattern metrics at a single extent and (iii be extended to other landscapes and scales.

  4. Charge-coupled devices for particle detection with high spatial resolution

    International Nuclear Information System (INIS)

    Farley, F.J.; Damerell, C.J.S.; Gillman, A.R.; Wickens, F.J.

    1980-10-01

    The results of a study of the possible application of a thin microelectronic device (the charge-coupled device) to high energy physics as particle detectors with good spatial resolution which can distinguish between tracks emerging from the primary vertex and those from secondary vertices due to the decay of short lived particles with higher flavours, are reported. Performance characteristics indicating the spatial resolution, particle discrimination, time resolution, readout time and lifetime of such detectors have been obtained. (U.K.)

  5. Diagnostic Accuracy and Inter-Observer Agreement of Shoulder Magnetic Resonance Arthrography in the Detection of Labral Lesion and Assessment of Lesion Location

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Song, Sook Yun; Choi, Jin Ha; Shin, Sang Jin [School of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the diagnostic accuracy and inter-observer agreement of magnetic resonance (MR) arthrography in the detection of labral lesions by location and to describe useful MR imaging findings of labral tears. Sixty-eight patients who underwent both pre-operative MR arthrography and arthroscopy were included. The location of the labrum was classified into anterior (2-6 o'clock), superior (12-2 o'clock), and posterior (6-12 o'clock). Sensitivity, specificity, accuracy, and inter-observer agreement of MR arthrography for the diagnosis of labral lesions by location were calculated. Frequency of MR imaging findings such as detachment, high signal intensity cleft, contour change, absence, and signal change of the labrum by location were analyzed. 35 anterior, 44 superior and 15 posterior labral lesions were detected by arthroscopy. The corresponding sensitivities were 91.4%, 79.5%, and 40.0%, specificities were 90.9%, 20.8%, and 86.8%, accuracies were 91.2%, 58.8%, and 76.5%, and kappa values were 0.823, 0.252, and 0.394, for anterior, superior, posterior lesions, respectively. The most common MR imaging findings were detachment in 60.0% of anterior labrums, high signal intensity cleft in 52.3% of superior labrums, and normal in 60.0% of posterior labrums. Diagnostic accuracy and inter-observer agreement of MR arthrography in the diagnosis of labral lesions are high in anterior labrums and low in superior or posterior labrums. The useful MR imaging findings of labral tears were different according to labral location.

  6. Accuracy of CT enterography and magnetic resonance enterography imaging to detect lesions preoperatively in patients undergoing surgery for Crohn's disease.

    Science.gov (United States)

    Seastedt, Kenneth P; Trencheva, Koiana; Michelassi, Fabrizio; Alsaleh, Doaa; Milsom, Jeffrey W; Sonoda, Toyooki; Lee, Sang W; Nandakumar, Govind

    2014-12-01

    CT enterography and magnetic resonance enterography have emerged as first-line imaging technologies for the evaluation of the gastrointestinal tract in Crohn's disease. The purpose of this work was to evaluate the accuracy of these imaging modalities to identify Crohn's disease lesions preoperatively. This was a retrospective chart review. The study was conducted at a single institution. Seventy-six patients with Crohn's disease with preoperative CT enterography and/or magnetic resonance enterography were included in the study. The number of stenoses, fistulas, and abscesses on CT enterography and/or magnetic resonance enterography before surgery were compared with operative findings. Forty patients (53%) were women, 46 (60%) underwent surgery for recurrent Crohn's disease, and 46 (57%) had previous abdominal surgery. Thirty-six (47%) had a preoperative CT enterography and 43 (57%) had a preoperative magnetic resonance enterography. CT enterography sensitivity was 75% for stenosis and 50% for fistula. MRE sensitivity was 68% for stenosis and 60% for fistula. The negative predictive values of CT enterography and magnetic resonance enterography for stenosis were very low (54% and 65%) and were 85% and 81% for fistula. CT enterography had 76% accuracy for stenosis and 79% for fistula; magnetic resonance enterography had 78% accuracy for stenosis and 85% for fistula. Both were accurate for abscess. False-negative rates for CT enterography were 50% for fistula and 25% for stenosis. False-negative rates for magnetic resonance enterography were 40% for fistula and 32% for stenosis. Unexpected intraoperative findings led to modification of the planned surgical procedure in 20 patients (26%). This study was limited by its small sample size, its retrospective nature, and that some studies were performed at outside institutions. CT enterography and magnetic resonance enterography in patients with Crohn's disease were accurate for the identification of abscesses but not for

  7. Accuracy of magnetic resonance studies in the detection of chondral and labral lesions in femoroacetabular impingement: systematic review and meta-analysis.

    Science.gov (United States)

    Saied, A M; Redant, C; El-Batouty, M; El-Lakkany, M R; El-Adl, W A; Anthonissen, J; Verdonk, R; Audenaert, E A

    2017-02-16

    Several types of Magnetic resonance imaging (MRI) are commonly used in imaging of femoroacetabular impingement (FAI), however till now there are no clear protocols and recommendations for each type. The aim of this meta-analysis is to detect the accuracy of conventional magnetic resonance imaging (cMRI), direct magnetic resonance arthrography (dMRA) and indirect magnetic resonance arthrography (iMRA) in the diagnosis of chondral and labral lesions in femoroacetabular impingement (FAI). A literature search was finalized on the 17th of May 2016 to collect all studies identifying the accuracy of cMRI, dMRA and iMRA in diagnosing chondral and labral lesions associated with FAI using surgical results (arthroscopic or open) as a reference test. Pooled sensitivity and specificity with 95% confidence intervals using a random-effects meta-analysis for MRI, dMRA and iMRA were calculated also area under receiver operating characteristic (ROC) curve (AUC) was retrieved whenever possible where AUC is equivocal to diagnostic accuracy. The search yielded 192 publications which were reviewed according inclusion and exclusion criteria then 21 studies fulfilled the eligibility criteria for the qualitative analysis with a total number of 828 cases, lastly 12 studies were included in the quantitative meta-analysis. Meta-analysis showed that as regard labral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.864, 0.833 and 0.88 and for dMRA were 0.91, 0.58 and 0.92. While in chondral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.76, 0.72 and 0.75 and for dMRA were 0.75, 0.79 and 0.83, while for iMRA were sensitivity of 0.722 and specificity of 0.917. The present meta-analysis showed that the diagnostic test accuracy was superior for dMRA when compared with cMRI for detection of labral and chondral lesions. The diagnostic test accuracy was superior for labral lesions when compared with chondral lesions in both cMRI and dMRA. Promising results are

  8. The diagnostic accuracy of TCD for intracranial arterial stenosis/occlusion in patients with acute ischemic stroke: the importance of time interval between detection of TCD and CTA.

    Science.gov (United States)

    Guan, Jingxia; Zhou, Qin; Ouyang, Huangqing; Zhang, Shaofeng; Lu, Zuneng

    2013-11-01

    To evaluate prospectively the diagnostic accuracy of transcranial doppler (TCD) as an additional screening tool for intracranial arterial steno-occlusive disease against computed tomography angiography (CTA) in patients with acute ischemic stroke (AIS) if both are performed in a short time interval. Between July 2011 and May 2012, 128 patients who were hospitalized within 24 hours of symptom onset and fulfilled the criteria for the clinical diagnosis of AIS were enrolled. Bedside detection of TCD was accomplished immediately after admission. High-resolution brain CTA was performed within 3 hours after the completion of TCD and the images were interpreted by a neuroradiologist blinded to TCD findings. The accuracy parameters of TCD against CTA were calculated after computation of true-positive, false-positive, true negative, and false-negative values. Among the 128 patients, there were 68 males and 60 females, aged 61.4 ± 17.5 years. The mean time interval between the detection of TCD and CTA was 89.7 (77.8) minutes. In 65% of patients, both examinations were performed with less than a half-hour interval between them. The diagnostic accuracy of TCD for different arteries showed slight distinction. Transcranial doppler demonstrated the most accurate diagnosis for middle cerebral artery (MCA), where TCD showed 35 true-positive, 0 false-negative, 1 false-positive, and 92 true-negative studies compared with CTA. Furthermore, elevated MCA velocities on TCD correlated well with the severity of intracranial stenosis detected on CTA. Vertebral artery (VA) is one of the arteries with the lowest sensitivity for TCD diagnosis (sensitivity 63.4%, specificity 96.5%, positive predictive value (PPV) 89.6%, negative predictive value (NPV) 84.8%, and accuracy 85.9%). In 20 cases (15.6%), TCD showed findings complementary to CTA (real-time embolization, collateral flow patterns, and steal phenomenon). Transcranial doppler shows high diagnostic accuracy against CTA if both are

  9. Near-real-time radiography detects 0.1% changes in areal density with 1-millimeter spatial resolution

    International Nuclear Information System (INIS)

    Stupin, D.M.

    1987-06-01

    Using digital subtraction radiography, the author detects an 0.1% change in areal density in a phantom. Areal density is the product rho x, where rho is the material density and x is the material thickness. Therefore, it is possible to detect an 0.1% difference in either density or thickness in unknown samples. A special x-ray television camera detects the areal density change on the phantom. In a difference image, formed by subtracting the 128-television-frame averages of the phantom image from the phantom-and-step image, the step is resolved with a 1-mm spatial resolution. Surprisingly, crossed 2-μm-diam tungsten wires that overlie the phantom are also detected. This procedure takes a few seconds. The performance of any digital imaging x-ray system will improve by using the averaging and digital subtraction techniques. 8 refs., 6 figs

  10. Attention Measures of Accuracy, Variability, and Fatigue Detect Early Response to Donepezil in Alzheimer's Disease: A Randomized, Double-blind, Placebo-Controlled Pilot Trial.

    Science.gov (United States)

    Vila-Castelar, Clara; Ly, Jenny J; Kaplan, Lillian; Van Dyk, Kathleen; Berger, Jeffrey T; Macina, Lucy O; Stewart, Jennifer L; Foldi, Nancy S

    2018-04-09

    Donepezil is widely used to treat Alzheimer's disease (AD), but detecting early response remains challenging for clinicians. Acetylcholine is known to directly modulate attention, particularly under high cognitive conditions, but no studies to date test whether measures of attention under high load can detect early effects of donepezil. We hypothesized that load-dependent attention tasks are sensitive to short-term treatment effects of donepezil, while global and other domain-specific cognitive measures are not. This longitudinal, randomized, double-blind, placebo-controlled pilot trial (ClinicalTrials.gov Identifier: NCT03073876) evaluated 23 participants newly diagnosed with AD initiating de novo donepezil treatment (5 mg). After baseline assessment, participants were randomized into Drug (n = 12) or Placebo (n = 11) groups, and retested after approximately 6 weeks. Cognitive assessment included: (a) attention tasks (Foreperiod Effect, Attentional Blink, and Covert Orienting tasks) measuring processing speed, top-down accuracy, orienting, intra-individual variability, and fatigue; (b) global measures (Alzheimer's Disease Assessment Scale-Cognitive Subscale, Mini-Mental Status Examination, Dementia Rating Scale); and (c) domain-specific measures (memory, language, visuospatial, and executive function). The Drug but not the Placebo group showed benefits of treatment at high-load measures by preserving top-down accuracy, improving intra-individual variability, and averting fatigue. In contrast, other global or cognitive domain-specific measures could not detect treatment effects over the same treatment interval. The pilot-study suggests that attention measures targeting accuracy, variability, and fatigue under high-load conditions could be sensitive to short-term cholinergic treatment. Given the central role of acetylcholine in attentional function, load-dependent attentional measures may be valuable cognitive markers of early treatment response.

  11. Diagnostic accuracy of audio-based seizure detection in patients with severe epilepsy and an intellectual disability

    NARCIS (Netherlands)

    Arends, Johan B.; van Dorp, Jasper; van Hoek, Dennis; Kramer, Niels; van Mierlo, Petra; van der Vorst, Derek; Tan, Francis I.Y.

    2016-01-01

    We evaluated the performance of audio-based detection of major seizures (tonic–clonic and long generalized tonic) in adult patients with intellectual disability living in an institute for residential care. Methods First, we checked in a random sample (n = 17, 102 major seizures) how many patients

  12. About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: a 3D zero-strain study.

    Science.gov (United States)

    Dall'Ara, E; Barber, D; Viceconti, M

    2014-09-22

    The accurate measurement of local strain is necessary to study bone mechanics and to validate micro computed tomography (µCT) based finite element (FE) models at the tissue scale. Digital volume correlation (DVC) has been used to provide a volumetric estimation of local strain in trabecular bone sample with a reasonable accuracy. However, nothing has been reported so far for µCT based analysis of cortical bone. The goal of this study was to evaluate accuracy and precision of a deformable registration method for prediction of local zero-strains in bovine cortical and trabecular bone samples. The accuracy and precision were analyzed by comparing scans virtually displaced, repeated scans without any repositioning of the sample in the scanner and repeated scans with repositioning of the samples. The analysis showed that both precision and accuracy errors decrease with increasing the size of the region analyzed, by following power laws. The main source of error was found to be the intrinsic noise of the images compared to the others investigated. The results, once extrapolated for larger regions of interest that are typically used in the literature, were in most cases better than the ones previously reported. For a nodal spacing equal to 50 voxels (498 µm), the accuracy and precision ranges were 425-692 µε and 202-394 µε, respectively. In conclusion, it was shown that the proposed method can be used to study the local deformation of cortical and trabecular bone loaded beyond yield, if a sufficiently high nodal spacing is used. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Accuracy of saline contrast sonohysterography in detection of endometrial polyps and submucosal leiomyomas in women of reproductive age with abnormal uterine bleeding: systematic review and meta-analysis.

    Science.gov (United States)

    Bittencourt, C A; Dos Santos Simões, R; Bernardo, W M; Fuchs, L F P; Soares Júnior, J M; Pastore, A R; Baracat, E C

    2017-07-01

    To analyze the diagnostic accuracy of two- (2D) and three- (3D) dimensional saline contrast sonohysterography (SCSH) in the detection of endometrial polyps and submucosal uterine leiomyomas in women of reproductive age with abnormal uterine bleeding compared with gold standard hysteroscopy. A systematic review of diagnostic studies that compared 2D- and/or 3D-SCSH with hysteroscopy and anatomopathology was conducted according to PRISMA and SEDATE recommendations. The databases MEDLINE, EMBASE and The Cochrane Library were searched electronically using specific terms with no restriction on language or publication year. Quality assessment of included studies was performed using the QUADAS-2 tool. Meta-analysis was performed with the Meta-DiSk program and data presented as forest plots and summary receiver-operating characteristics (SROC) curves. Pooled sensitivity, specificity and positive (LR+) and negative (LR-) likelihood ratios of SCSH in the detection of uterine cavity abnormalities were calculated. A total of 1398 citations were identified and five studies were included in the systematic review and meta-analysis. Pooled sensitivity and specificity of 2D-SCSH in detecting endometrial polyps were 93% (95% CI, 89-96%) and 81% (95% CI, 76-86%), respectively, with pooled LR+ of 5.41 (95% CI, 2.60-11.28) and LR- of 0.10 (95% CI, 0.06-0.17). In the detection of submucosal uterine leiomyomas, pooled sensitivity and specificity were 94% (95% CI, 89-97%) and 81% (95% CI, 76-86%), respectively, with pooled LR+ of 4.25 (95% CI, 2.20-8.21) and LR- of 0.11 (95% CI, 0.05-0.22). 2D-SCSH had good accuracy in detecting endometrial polyps and submucosal uterine leiomyomas, with areas under the SROC curves of 0.97 ± 0.02 and 0.97 ± 0.03, respectively. Studies that analyzed the diagnostic accuracy of 3D-SCSH could not be compared due to high heterogeneity related to menopausal status, type of technique used and primary outcome being investigation of infertility. 2D

  14. Spatial statistics detect clustering patterns of kidney diseases in south-eastern Romania

    Directory of Open Access Journals (Sweden)

    Ruben I.

    2016-02-01

    Full Text Available Medical geography was conceptualized almost ten years ago due to its obvious usefulness in epidemiological research. Still, numerous diseases in many regions were neglected in these aspects of research, and the prevalence of kidney diseases in Eastern Europe is such an example. We evaluated the spatial patterns of main kidney diseases in south-eastern Romania, and highlighted the importance of spatial modeling in medical management in Romania. We found two statistically significant hotspots of kidney diseases prevalence. We also found differences in the spatial patterns between categories of diseases. We propose to speed up the process of creating a national database of records on kidney diseases. Offering the researchers access to a national database will allow further epidemiology studies in Romania and finally lead to a better management of medical services.

  15. Diagnostic Accuracy of Preoperative Neutrophil-to-Lymphocyte and Platelet-to-Lymphocyte Ratios in Detecting Occult Papillary Thyroid Microcarcinomas in Benign Multinodular Goitres

    Directory of Open Access Journals (Sweden)

    Dimitrios K. Manatakis

    2018-01-01

    Full Text Available Objective. To investigate the diagnostic accuracy of neutrophil-to-lymphocyte (NLR and platelet-to-lymphocyte (PLR ratios in detecting occult papillary thyroid microcarcinomas in benign, multinodular goitres. Methods. 397 total thyroidectomy patients were identified from the institutional thyroid surgery database between 2007 and 2016 (94 males, 303 females, mean age 53 ± 14.5 years. NLR and PLR were calculated as the absolute neutrophil and absolute platelet counts divided by the absolute lymphocyte count, respectively, based on the preoperative complete blood cell count. Results. NLR was significantly higher in carcinomas and microcarcinomas compared to benign pathology (p=0.026, whereas a direct association could not be established for PLR. Both NLR and PLR scored low in all parameters of diagnostic accuracy, with overall accuracy ranging between 45 and 50%. Conclusions. As surrogate indices of the systemic inflammatory response, NLR and PLR are inexpensive and universally available from routine blood tests. Although we found higher NLR values in cases of malignancy, NLR and PLR cannot effectively predict the presence of occult papillary microcarcinomas in otherwise benign, multinodular goitres.

  16. Accuracy of Combined Computed Tomography Colonography and Dual Energy Iiodine Map Imaging for Detecting Colorectal masses using High-pitch Dual-source CT.

    Science.gov (United States)

    Sun, Kai; Han, Ruijuan; Han, Yang; Shi, Xuesen; Hu, Jiang; Lu, Bin

    2018-02-28

    To evaluate the diagnostic accuracy of combined computed tomography colonography (CTC) and dual-energy iodine map imaging for detecting colorectal masses using high-pitch dual-source CT, compared with optical colonography (OC) and histopathologic findings. Twenty-eight consecutive patients were prospectively enrolled in this study. All patients were underwent contrast-enhanced CTC acquisition using dual-energy mode and OC and pathologic examination. The size of the space-occupied mass, the CT value after contrast enhancement, and the iodine value were measured and statistically compared. The sensitivity, specificity, accuracy rate, and positive predictive and negative predictive values of dual-energy contrast-enhanced CTC were calculated and compared between conventional CTC and dual-energy iodine images. The iodine value of stool was significantly lower than the colonic neoplasia (P dual-energy iodine maps imaging was 95.6% (95% CI = 77.9%-99.2%). The specificity of the two methods was 42.8% (95% CI = 15.4%-93.5%) and 100% (95% CI = 47.9%-100%; P = 0.02), respectively. Compared with optical colonography and histopathology, combined CTC and dual-energy iodine maps imaging can distinguish stool and colonic neoplasia, distinguish between benign and malignant tumors initially and improve the diagnostic accuracy of CTC for colorectal cancer screening.

  17. Use of multivariate analysis to improve the accuracy of radionuclide angiography with stress in detecting coronary artery disease in men

    International Nuclear Information System (INIS)

    Greenberg, P.S.; Bible, M.; Ellestad, M.H.; Berge, R.; Johnson, K.; Hayes, M.

    1983-01-01

    A multivariate analysis (MVA) system was derived retrospectively from a population of 76 males with coronary artery disease and 18 control subjects. Posterior probabilities were then derived from such a system prospectively in a new male population of 11 subjects with normal coronary arteries and hemodynamics and 63 patients with coronary artery disease. The sensitivity was 84% compared to that for change in ejection fraction (delta EF) greater than or equal to 5 criterion of 71% (p less than 0.01), the specificity was 91% compared to 73% for the delta EF greater than or equal to 5 criterion (p greater than 0.05), and the correct classification rate was 85% compared to 72% for the delta EF greater than or equal to 5 criterion (p less than 0.01). The significant variables were: change in EF with exercise, percent maximal heart rate, change in end-diastolic volume (delta EDV) with exercise, change in R wave, and exercise duration. Application of the multivariate approach to radionuclide imaging with stress, including both exercise and nuclear parameters, significantly improved the diagnostic accuracy of the test and allowed for a probability statement concerning the likelihood of disease

  18. Diagnostic accuracy of triple-contrast multi-detector computed tomography for detection of penetrating gastrointestinal injury: a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Saksobhavivat, Nitima [Faculty of Medicine Ramathibodi Hospital, Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ratchathewi, Bangkok (Thailand); Shanmuganathan, Kathirkamanathan; Boscak, Alexis R.; Sliker, Clint W.; Bodanapally, Uttam K.; Archer-Arroyo, Krystal; Miller, Lisa A.; Fleiter, Thorsten R.; Alexander, Melvin T.; Mirvis, Stuart E. [University of Maryland School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Baltimore, MD (United States); Stein, Deborah M.; Scalea, Thomas M. [University of Maryland School of Medicine, R. Adams Cowley Shock Trauma Center, Baltimore, MD (United States)

    2016-11-15

    Neither the performance of CT in diagnosing penetrating gastrointestinal injury nor its ability to discriminate patients requiring either observation or surgery has been determined. This was a prospective, single-institutional observational study of patients with penetrating injury to the torso who underwent CT. Based on CT signs, reviewers determined the presence of a gastrointestinal injury and the need for surgery or observation. The primary outcome measures were operative findings and clinical follow-up. CT results were compared with the primary outcome measures. Of one hundred and seventy-one patients (72 gunshot wounds, 99 stab wounds; age range, 18-57 years; median age, 28 years) with penetrating torso trauma who underwent CT, 45 % were followed by an operation and 55 % by clinical follow up. Thirty-five patients had a gastrointestinal injury at surgery. The sensitivity, specificity, and accuracy of CT for diagnosing a gastrointestinal injury for all patients were each 91 %, and for predicting the need for surgery, they were 94 %, 93 %, 93 %, respectively. Among the 3 % of patients who failed observation, 1 % had a gastrointestinal injury. CT is a useful technique to diagnose gastrointestinal injury following penetrating torso injury. CT can help discriminate patients requiring observation or surgery. (orig.)

  19. Comparison of diagnostic accuracy of dual-source CT and conventional angiography in detecting congenital heart diseases

    International Nuclear Information System (INIS)

    Sedaghat, Fariborz; Pouraliakbar, Hamidreza; Motevalli, Marzieh; Karimi, Mohammad Ali; Armand, Sandbad

    2014-01-01

    Cardiac dual-source computed tomography (DSCT) is primarily used for coronary arteries. There are limited studies about the application of DSCT for congenital heart diseases. The aim of this study was to determine the diagnostic value of DSCT in the cardiac anomalies. The images of DSCTs and conventional angiographies of 36 patients (21 male; mean age: 8.5 month) with congenital heart diseases were reviewed and the parameters of diagnostic value of these methods were compared. Cardiac surgery was the gold standard. A total of 105 cardiac anomalies were diagnosed at surgery. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DSCT were 98.25%, 97.9%, 98.1%, 99.07%, and 98.2%, respectively. The corresponding values of angiography were 95.04%, 98.7%, 97.8%, 98.1%, and 98%, respectively. Only one atrial septal defect (ASD) and two patent ductus arteriosus (PDA) were missed by DSCT. Angiography missed two ASD and two PDA. DSCT also provided important additional findings (n=35) about the intrathoracic or intraabdominal organs. DSCT is a highly accurate diagnostic modality for congenital heart diseases, obviating the need for invasive modalities. Beside its noninvasive nature, the advantage of DSCT over the angiography is its ability to provide detailed anatomical information about the heart, vessels, lungs and intraabdominal organs

  20. Analysis of the spatial and temporal accuracy of heating in the prostate gland using transurethral ultrasound therapy and active MR temperature feedback

    International Nuclear Information System (INIS)

    Chopra, Rajiv; Tang, Kee; Burtnyk, Mathieu; Boyes, Aaron; Bronskill, Michael; Sugar, Linda; Appu, Sree; Klotz, Laurence

    2009-01-01

    A new MRI-guided therapy is being developed as a minimally invasive treatment for localized prostate cancer utilizing high-intensity ultrasound energy to generate a precise region of thermal coagulation within the prostate gland. The purpose of this study was to evaluate in vivo the capability to produce a spatial heating pattern in the prostate that accurately matched the shape of a target region using transurethral ultrasound heating and active MR temperature feedback. Experiments were performed in a canine model (n = 9) in a 1.5 T MR imager using a prototype device comprising a single planar transducer operated under rotational control. The spatial temperature distribution, measured every 5 s with MR thermometry, was used to adjust the acoustic power and rotation rate in order to achieve a temperature of 55 0 C along the outer boundary of the target region. The results demonstrated the capability to produce accurate spatial heating patterns within the prostate gland. An average temperature of 56.2 ± 0.6 0 C was measured along the outer boundary of the target region across all experiments in this study. The average spatial error between the target boundary and the 55 0 C isotherm was 0.8 ± 0.7 mm (-0.2 to 3.2 mm), and the overall treatment time was ≤20 min for all experiments. Excellent spatial agreement was observed between the temperature information acquired with MRI and the pattern of thermal damage measured on H and E-stained tissue sections. This study demonstrates the benefit of adaptive energy delivery using active MR temperature feedback, and an excellent capability to treat precise regions within the prostate gland with this technology.

  1. Accuracy of the Enhanced Liver Fibrosis Test vs Fibrotest, Elastography and Indirect Markers in Detection of Advanced Fibrosis in Patients with Alcoholic Liver Disease

    DEFF Research Database (Denmark)

    Thiele, Maja; Madsen, Bjørn Stæhr; Hansen, Janne Fuglsang

    2018-01-01

    BACKGROUND & AIMS: Alcohol is the leading cause of cirrhosis and liver-related mortality, but we lack serum markers to detect compensated disease. We compared the accuracy of the Enhanced Liver Fibrosis test (ELF), the FibroTest, liver stiffness measurements (made by transient elastography and 2......-dimensional shear-wave elastography), and 6 indirect marker tests in detection of advanced liver fibrosis (Kleiner stage ≥F3). METHODS: We performed a prospective study of 10 liver fibrosis markers (patented and not), all performed on the same day. Patients were recruited from primary centers (municipal...... significantly from those of liver stiffness measurement in intention-to-diagnose analyses (AUROC for transient elastography, 0.90), but did differ in the per-protocol analysis (AUROC for transient elastography, 0.97) (P=.521 and .004 for comparison with ELF). Adding a serum marker to transient elastography...

  2. Detection of suspicious malignant cervical lymph nodes of unknown origin: diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy with nodal size and central necrosis correlate

    International Nuclear Information System (INIS)

    Lo, C.-P.; Chen, C.-Y.; Chin, S-.C.; Lee, K.-W.; Hsueh, C.-J.; Juan, C.-J.; Kao, H.-W.; Huang, G.-S.

    2007-01-01

    To assess the role of ultrasound-guided fine-needle aspiration biopsy (US-guided FNAB) in the diagnostic workup of suspicious malignant cervical lymph nodes in patients with palpable neck masses and without known primary cancer. The diagnostic accuracy of imaging morphologic criteria, including sizes and central necrosis for assessing suspicious malignant nodes, were also examined. This is a retrospective study of 426 patients with palpable neck masses from an outpatient department evaluated with computed tomography, magnetic resonance imaging, or US. US-guided FNABs were performed in 102 patients with suspicious malignant cervical lymph nodes at a single institution. Cytologically positive lymph nodes (n = 12) were further validated with excisional biopsy. Negative lymph nodes (n = 90) were either excised (n = 10) or followed up by imaging studies for at least one year (n = 80). The diagnostic accuracy of the FNABs along with the imaging findings of nodal sizes and presence of central necrosis, which were classified by a consensus of 2 radiologists, were assessed. Twelve malignant nodes were detected with US-guided FNAB with one false-positive and one false-negative result. The overall sensitivity, specificity, and accuracy for FNAB were 91.7%, 98.9%, and 98.0%. respectively. The sensitivity, specificity, and accuracy were 66.7%, 30.0%, and 34.3% for size criterion and 75.0%, 83.3%, and 82.3% for central necrosis criterion. The size of cervical lymph node does not appear to be an important imaging criterion for assessing suspicious malignant lymph nodes, compared with the criterion of central necrosis. US-guided FNAB is highly specific and sensitive in the diagnostic workup of suspicious malignant cervical lymph nodes in patients without known primary cancers. (author)

  3. Accuracy of cystatin C for the detection of abnormal renal function in children undergoing chemotherapy for malignancy: a systematic review using individual patient data.

    Science.gov (United States)

    Whiting, Penny; Birnie, Kate; Sterne, Jonathan A C; Jameson, Catherine; Skinner, Rod; Phillips, Bob

    2018-05-01

    We conducted a systematic review and individual patient data (IPD) meta-analysis to examine the utility of cystatin C for evaluation of glomerular function in children with cancer. Eligible studies evaluated the accuracy of cystatin C for detecting poor renal function in children undergoing chemotherapy. Study quality was assessed using QUADAS-2. Authors of four studies shared IPD. We calculated the correlation between log cystatin C and GFR stratified by study and measure of cystatin C. We dichotomized the reference standard at GFR 80 ml/min/1.73m 2 and stratified cystatin C at 1 mg/l, to calculate sensitivity and specificity in each study and according to age group (0-4, 5-12, and ≥ 13 years). In sensitivity analyses, we investigated different GFR and cystatin C cut points. We used logistic regression to estimate the association of impaired renal function with log cystatin C and quantified diagnostic accuracy using the area under the ROC curve (AUC). Six studies, which used different test and reference standard thresholds, suggested that cystatin C has the potential to monitor renal function in children undergoing chemotherapy for malignancy. IPD data (504 samples, 209 children) showed that cystatin C has poor sensitivity (63%) and moderate specificity (89%), although use of a GFR cut point of C has better diagnostic accuracy than creatinine as a test for glomerular dysfunction in young people undergoing treatment for cancer. Diagnostic accuracy is not sufficient for it to replace current reference standards for predicting clinically relevant impairments that may alter dosing of important nephrotoxic agents.

  4. Shaping and detecting mid-IR light with a spatial light modulator

    CSIR Research Space (South Africa)

    Maweza, Elijah L

    2016-10-01

    Full Text Available modulator Maweza, Elijah L Gailele, Lucas M Strauss, Hencharl J Litvin, Ihar Forbes, Andrew Dudley, Angela L ABSTRACT: We demonstrate the operation and calibration of a spatial light modulator in the mid-IR region by creating and measuring...

  5. One-hour protocol stress myocardial scintigraphy. Prospective study of diagnostic accuracy for the detection of coronary artery stenosis

    International Nuclear Information System (INIS)

    Matsuda, Junko; Miyamoto, Nobuhide; Onitsuka, Hisamitsu; Ikushima, Ippei; Unoki, Toshihide; Takenaga, Makoto; Koiwaya, Yasushi; Eto, Tanenao

    1999-01-01

    A one-hour protocol for stress myocardial scintigraphy using technetium-99m-tetrofosmin (Tc-tetrofosmin) was compared with coronary arteriography for the detection of coronary artery stenosis in 90 consecutive patients without prior myocardial infarction, revascularization procedure or vasospastic angina. Tc-tetrofosmin stress myocardial scintigraphy acquired a rest image 20 min after intravenous administration of Tc-tetrofosmin (185 MBq, 1/5 vial) using a three-head gamma camera collecting 20-sec views over 360 deg. The stress test using bicycle ergometer was performed and administration of Tc-tetrofosmin (740 MBq, 4/5 vial) was repeated at the peak stress point. The stress image was acquired 15 min after the second injection with 5-sec views over 360 deg. Coronary arteriography revealed the presence of significant coronary artery stenosis (>75%) in 56 vessels of 45 patients, including 35 patients with single-vessel disease, 5 with two-vessel disease, 2 with three-vessel disease, and 3 with left main trunk disease. The overall sensitivity and specificity for the detection of coronary artery disease by visual analysis were 91.1% and 77.8%, respectively, and by quantitative analyses (using bull's-eye method) were 95.6% and 91.1%, respectively. The individual stenotic vessel sensitivities in the right coronary artery, left anterior descending artery, and left circumflex artery were 84.6%, 90.9%, and 78.6%, respectively. The specificities were 97.3%, 95.9%, and 100.0%, respectively. These results suggest that stress myocardial scintigraphy using the present new protocol is a promising approach for the detection of coronary artery stenosis. (author)

  6. Accuracy of high-field intraoperative MRI in the detectability of residual tumor in glioma grade IV resections

    Energy Technology Data Exchange (ETDEWEB)

    Hesselmann, Volker; Mager, Ann-Kathrin [Asklepios-Klinik Nord, Hamburg (Germany). Radiology/Neurologie; Goetz, Claudia; Kremer, Paul [Asklepios-Klinik Nord, Hamburg (Germany). Dept. of Neurosurgery; Detsch, Oliver [Asklepios-Klinik Nord, Hamburg (Germany). Dept. of Anaesthesiology and Intensive Care Medicine; Theisgen, Hannah-Katharina [Universitaetsklinikum Schleswig-Holstein, Kiel (Germany). Dept. of Neurosurgery; Friese, Michael; Gottschalk, Joachim [Asklepios-Klinik Nord, Hamburg (Germany). Dept. of Pathology and Neuropathology; Schwindt, Wolfram [Univ. Hospital Muenster (Germany). Dept. of Clinical Radiology

    2017-06-15

    To assess the sensitivity/specificity of tumor detection by T1 contrast enhancement in intraoperative MRI (ioMRI) in comparison to histopathological assessment as the gold standard in patients receiving surgical resection of grade IV glioblastoma. 68 patients with a primary or a recurrent glioblastoma scheduled for surgery including fluorescence guidance and neuronavigation were included (mean age: 59 years, 26 female, 42 male patients). The ioMRI after the first resection included transverse FLAIR, DWI, T2-FFE and T1 - 3 d FFE ± GD-DPTA. The second resection was performed whenever residual contrast-enhancing tissue was detected on ioMRI. Resected tissue samples were histopathologically evaluated (gold standard). Additionally, we evaluated the early postoperative MRI scan acquired within 48 h post-OP for remaining enhancing tissue and compared them with the ioMRI scan. In 43 patients ioMRI indicated residual tumorous tissue, which could be confirmed in the histological specimens of the second resection. In 16 (4 with recurrent, 12 with primary glioblastoma) cases, ioMRI revealed truly negative results without residual tumor and follow-up MRI confirmed complete resection. In 7 cases (3 with recurrent, 4 with primary glioblastoma) ioMRI revealed a suspicious result without tumorous tissue in the histopathological workup. In 2 (1 for each group) patients, residual tumorous tissue was detected in spite of negative ioMRI. IoMRI had a sensitivity of 95 % (94 % recurrent and 96 % for primary glioblastoma) and a specificity of 69.5 % (57 % and 75 %, respectively). The positive predictive value was 86 % (84 % for recurrent and 87 % for primary glioblastoma), and the negative predictive value was 88 % (80 % and 92 %, respectively). ioMRI is effective for detecting remaining tumorous tissue after glioma resection. However, scars and leakage of contrast agent can be misleading and limit specificity. Intraoperative MRI (ioMRI) presents with a high sensitivity for residual

  7. Accuracy of high-field intraoperative MRI in the detectability of residual tumor in glioma grade IV resections

    International Nuclear Information System (INIS)

    Hesselmann, Volker; Mager, Ann-Kathrin; Goetz, Claudia; Kremer, Paul; Detsch, Oliver; Theisgen, Hannah-Katharina; Friese, Michael; Gottschalk, Joachim; Schwindt, Wolfram

    2017-01-01

    To assess the sensitivity/specificity of tumor detection by T1 contrast enhancement in intraoperative MRI (ioMRI) in comparison to histopathological assessment as the gold standard in patients receiving surgical resection of grade IV glioblastoma. 68 patients with a primary or a recurrent glioblastoma scheduled for surgery including fluorescence guidance and neuronavigation were included (mean age: 59 years, 26 female, 42 male patients). The ioMRI after the first resection included transverse FLAIR, DWI, T2-FFE and T1 - 3 d FFE ± GD-DPTA. The second resection was performed whenever residual contrast-enhancing tissue was detected on ioMRI. Resected tissue samples were histopathologically evaluated (gold standard). Additionally, we evaluated the early postoperative MRI scan acquired within 48 h post-OP for remaining enhancing tissue and compared them with the ioMRI scan. In 43 patients ioMRI indicated residual tumorous tissue, which could be confirmed in the histological specimens of the second resection. In 16 (4 with recurrent, 12 with primary glioblastoma) cases, ioMRI revealed truly negative results without residual tumor and follow-up MRI confirmed complete resection. In 7 cases (3 with recurrent, 4 with primary glioblastoma) ioMRI revealed a suspicious result without tumorous tissue in the histopathological workup. In 2 (1 for each group) patients, residual tumorous tissue was detected in spite of negative ioMRI. IoMRI had a sensitivity of 95 % (94 % recurrent and 96 % for primary glioblastoma) and a specificity of 69.5 % (57 % and 75 %, respectively). The positive predictive value was 86 % (84 % for recurrent and 87 % for primary glioblastoma), and the negative predictive value was 88 % (80 % and 92 %, respectively). ioMRI is effective for detecting remaining tumorous tissue after glioma resection. However, scars and leakage of contrast agent can be misleading and limit specificity. Intraoperative MRI (ioMRI) presents with a high sensitivity for residual

  8. The application in detection the position accuracy of the multi-leaf collimator of Varian linear accelerator with dynamic therapy log files

    International Nuclear Information System (INIS)

    Li Changhu; Xu Liming; Teng Jianjian; Ge Wei; Zhang Jun; Ma Guangdong

    2010-01-01

    Objective: To explorer the application in detection the position accuracy of the multileaf collimator of Varian accelerator with dynamic therapy log files. Methods: A pre-designed MLC format files named PMLC for two Varian accelerators, the dynamic treatment log files were recorded 10 times on a different date, and be converted into the MLC format files named DMLC, compared with the original plan PMLC, so we can analysis two files for each leaf position deviation. In addition, we analysis the repeatability of MLC leaves position accuracy between 10 dynalog files of two accelerators. Results: No statistically significant difference between the average position of the 10 times leaf position of the two accelerators,their were 0.29 -0.29 and 0.29 -0.30 (z = -0.77, P=0.442). About 40%, 30%, 20% and 10% of the leaf position deviation was at ≤0.2 mm, 0.3 mm, 0.5 mm and 0.4 mm, respectively. the maximum value was 0.5 mm. More than 86% of the leaf position are completely coincident between 10 dynamic treatment files of two accelerators. The rate of position deviation no more 0. 05 mm was 96. 6% and 97.3%, respectively. And the maximum value was 0.09 mm. Conclusions: Dynamic treatment log file is a splendid tool in testing the actual position of multi-leaf collimator. The multi-leaf collimator of two accelerators be detected are precise and stabilized. (authors)

  9. Accuracy of point-of-care serum creatinine devices for detecting patients at risk of contrast-induced nephropathy: a critical overview.

    Science.gov (United States)

    Martínez Lomakin, Felipe; Tobar, Catalina

    2014-12-01

    Contrast-induced nephropathy (CIN) is a common event in hospitals, with reported incidences ranging from 1 to 30%. Patients with underlying kidney disease have an increased risk of developing CIN. Point-of-care (POC) creatinine devices are handheld devices capable of providing quantitative data on a patient's kidney function that could be useful in stratifying preventive measures. This overview aims to synthesize the current evidence on diagnostic accuracy and clinical utility of POC creatinine devices in detecting patients at risk of CIN. Five databases were searched for diagnostic accuracy studies or clinical trials that evaluated the usefulness of POC devices in detecting patients at risk of CIN. Selected articles were critically appraised to assess their individual risk of bias by the use of standard criteria; 13 studies were found that addressed the diagnostic accuracy or clinical utility of POC creatinine devices. Most studies incurred a moderate to high risk of bias. Overall concordance between POC devices and reference standards (clinical laboratory procedures) was found to be moderate, with 95% limits of agreement often lying between -35.4 and +35.4 µmol/L (-0.4 and +0.4 mg/dL). Concordance was shown to decrease with worsening kidney function. Data on the clinical utility of these devices were limited, but a significant reduction in time to diagnosis was reported in two studies. Overall, POC creatinine devices showed a moderate concordance with standard clinical laboratory creatinine measurements. Several biases could have induced optimism in these estimations. Results obtained from these devices may be unreliable in cases of severe kidney failure. Randomized trials are needed to address the clinical utility of these devices.

  10. The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study.

    Science.gov (United States)

    Menem, R; Barngkgei, I; Beiruti, N; Al Haffar, I; Joury, Easter

    2017-04-01

    The aim of this in vivo study was to test the diagnostic accuracy of a pen-type laser fluorescence (LFpen) device in detecting approximal caries lesions, in posterior permanent teeth, at the cavitation and non-cavitation thresholds, and compare it with that of digital bitewing radiography. Thirty patients (aged 18-37), who attended the Faculty of Dentistry at Damascus University for a dental examination, were consecutively screened. Ninety approximal surfaces of posterior permanent teeth without frank cavitations, enamel hypoplasia or restorations were selected and examined using the LFpen (DIAGNOdent pen) and digital bitewing radiography. The reference standard was the visual-tactile inspection, after performing temporary tooth separation, using orthodontic rubber rings, placed for 7 days. The status of included approximal surfaces was recorded as intact/sound, with white/brown spots or cavitated. One trained examiner performed all examinations. There were statistically significant differences in LFpen readings between the three types of approximal surface status (P 16 and 8 at the cavitation and non-cavitation thresholds respectively. The sensitivity, specificity and accuracy (measured by the area under the receiver-operating characteristic curve) were 100, 85 and 95 and 92, 90 and 95% at the cavitation and non-cavitation thresholds respectively. The intra-class correlation coefficient for intra-examiner reliability was 0.95. The diagnostic accuracy of the LFpen was significantly higher than that of digital bitewing radiography (P < 0.001). The LFpen's diagnostic performance was accurate and significantly better than digital bitewing radiography in detecting approximal caries lesions, in posterior permanent teeth.

  11. The accuracy of the SONOBREAST statistical model in comparison to BI-RADS for the prediction of malignancy in solid breast nodules detected at ultrasonography.

    Science.gov (United States)

    Paulinelli, Regis R; Oliveira, Luis-Fernando P; Freitas-Junior, Ruffo; Soares, Leonardo R

    2016-01-01

    The objective of the present study was to compare the accuracy of SONOBREAST for the prediction of malignancy in solid breast nodules detected at ultrasonography with that of the BI-RADS system and to assess the agreement between these two methods. This prospective study included 274 women and evaluated 500 breast nodules detected at ultrasonography. The probability of malignancy was calculated based on the SONOBREAST model, available at www.sonobreast.com.br, and on the BI-RADS system, with results being compared with the anatomopathology report. The lesions were considered suspect in 171 cases (34.20%), according to both SONOBREAST and BI-RADS. Agreement between the methods was perfect, as shown by a Kappa coefficient of 1 (pBI-RADS proved identical insofar as sensitivity (95.40%), specificity (78.69%), positive predictive value (48.54%), negative predictive value (98.78%) and accuracy (81.60%) are concerned. With respect to the categorical variables (BI-RADS categories 3, 4 and 5), the area under the receiver operating characteristic (ROC) curve was 94.41 for SONOBREAST (range 92.20-96.62) and 89.99 for BI-RADS (range 86.60-93.37). The accuracy of the SONOBREAST model is identical to that found with BI-RADS when the same parameters are used with respect to the cut-off point at which malignancy is suspected. Regarding the continuous probability of malignancy with BI-RADS categories 3, 4 and 5, SONOBREAST permits a more precise and individualized evaluation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. An iterative detection method of MIMO over spatial correlated frequency selective channel: using list sphere decoding for simplification

    Science.gov (United States)

    Shi, Zhiping; Yan, Bing

    2010-08-01

    In multiple-input multiple-output(MIMO) wireless systems, combining good channel codes(e.g., Non-binary Repeat Accumulate codes) with adaptive turbo equalization is a good option to get better performance and lower complexity under Spatial Correlated Frequency Selective(SCFS) Channel. The key of this method is after joint antennas MMSE detection (JAD/MMSE) based on interruption cancelling using soft information, considering the detection result as an output of a Gaussian equivalent flat fading channel, and performing maximum likelihood detection(ML) to get more correct estimated result. But the using of ML brings great complexity increase, which is not allowed. In this paper, a low complexity method called list sphere decoding is introduced and applied to replace the ML in order to simplify the adaptive iterative turbo equalization system.

  13. Spatial-Temporal Synchrophasor Data Characterization and Analytics in Smart Grid Fault Detection, Identification, and Impact Causal Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Huaiguang; Dai, Xiaoxiao; Gao, David Wenzhong; Zhang, Jun Jason; Zhang, Yingchen; Muljadi, Eduard

    2016-09-01

    An approach of big data characterization for smart grids (SGs) and its applications in fault detection, identification, and causal impact analysis is proposed in this paper, which aims to provide substantial data volume reduction while keeping comprehensive information from synchrophasor measurements in spatial and temporal domains. Especially, based on secondary voltage control (SVC) and local SG observation algorithm, a two-layer dynamic optimal synchrophasor measurement devices selection algorithm (OSMDSA) is proposed to determine SVC zones, their corresponding pilot buses, and the optimal synchrophasor measurement devices. Combining the two-layer dynamic OSMDSA and matching pursuit decomposition, the synchrophasor data is completely characterized in the spatial-temporal domain. To demonstrate the effectiveness of the proposed characterization approach, SG situational awareness is investigated based on hidden Markov model based fault detection and identification using the spatial-temporal characteristics generated from the reduced data. To identify the major impact buses, the weighted Granger causality for SGs is proposed to investigate the causal relationship of buses during system disturbance. The IEEE 39-bus system and IEEE 118-bus system are employed to validate and evaluate the proposed approach.

  14. Attentional effects on preattentive vision: Spatial precues affect the detection of simple features

    NARCIS (Netherlands)

    Theeuwes, J.; Kramer, A.F.; Atchley, P.

    1999-01-01

    Most accounts of visual perception hold that the detection of primitive features occurs preattentively, in parallel across the visual field. Evidence that preattentive vision operates without attentional limitations comes from visual search tasks in which the detection of the presence or absence of

  15. Detecting high spatial variability of ice shelf basal mass balance, Roi Baudouin Ice Shelf, Antarctica

    Directory of Open Access Journals (Sweden)

    S. Berger

    2017-11-01

    Full Text Available Ice shelves control the dynamic mass loss of ice sheets through buttressing and their integrity depends on the spatial variability of their basal mass balance (BMB, i.e. the difference between refreezing and melting. Here, we present an improved technique – based on satellite observations – to capture the small-scale variability in the BMB of ice shelves. As a case study, we apply the methodology to the Roi Baudouin Ice Shelf, Dronning Maud Land, East Antarctica, and derive its yearly averaged BMB at 10 m horizontal gridding. We use mass conservation in a Lagrangian framework based on high-resolution surface velocities, atmospheric-model surface mass balance and hydrostatic ice-thickness fields (derived from TanDEM-X surface elevation. Spatial derivatives are implemented using the total-variation differentiation, which preserves abrupt changes in flow velocities and their spatial gradients. Such changes may reflect a dynamic response to localized basal melting and should be included in the mass budget. Our BMB field exhibits much spatial detail and ranges from −14.7 to 8.6 m a−1 ice equivalent. Highest melt rates are found close to the grounding line where the pressure melting point is high, and the ice shelf slope is steep. The BMB field agrees well with on-site measurements from phase-sensitive radar, although independent radar profiling indicates unresolved spatial variations in firn density. We show that an elliptical surface depression (10 m deep and with an extent of 0.7 km × 1.3 km lowers by 0.5 to 1.4 m a−1, which we tentatively attribute to a transient adaptation to hydrostatic equilibrium. We find evidence for elevated melting beneath ice shelf channels (with melting being concentrated on the channel's flanks. However, farther downstream from the grounding line, the majority of ice shelf channels advect passively (i.e. no melting nor refreezing toward the ice shelf front. Although the absolute, satellite

  16. Diagnostic accuracy of {sup 18}F-FDG PET/CT for detection of suspected recurrence in patients with oesophageal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Punit; Jain, Sachin; Karunanithi, Sellam; Malhotra, Arun; Bal, Chandrasekhar; Kumar, Rakesh [All India Institute of Medical Sciences, Department of Nuclear Medicine, New Delhi (India); Pal, Sujoy [All India Institute of Medical Sciences, Department of Surgical Gastroenterology, New Delhi (India); Julka, Pramod Kumar [All India Institute of Medical Sciences, Department of Radiation Oncology, New Delhi (India); Thulkar, Sanjay [All India Institute of Medical Sciences, Department of Radiodiagnosis, New Delhi (India)

    2014-06-15

    To evaluate the role of {sup 18}F-FDG PET/CT in the detection of recurrence in patients with oesophageal carcinoma, suspected clinically or following conventional investigations. This was a retrospective study. Data from 180 patients (age 56.3 ± 10.4 years; 126 men, 54 women) with histopathologically proven oesophageal carcinoma (squamous cell 115, adenocarcinoma 59, neuroendocrine carcinoma 4, small cell 1, poorly differentiated 1) who had undergone 227 {sup 18}F-FDG PET/CT studies for suspected recurrence were analysed. Recurrence was suspected clinically or following conventional investigations. PET/CT images were revaluated by two nuclear medicine physicians in consensus. Findings were grouped into local, nodal and distant recurrence. Results were compared to those from contrast-enhanced (CE) CT when available (109 patients). Clinical/imaging follow-up (minimum 6 months) with histopathology (when available) was taken as the reference standard. Of the 227 {sup 18}F-FDG PET/CT studies,166 were positive and 61 were negative for recurrent disease. PET/CT showed local recurrence in 134, nodal recurrence in 115 and distant recurrence in 47, with more than one site of recurrence in 34. The PET/CT findings were true-positive in 153 studies, true-negative in 54, false-positive in 13 and false-negative in 7. The sensitivity of {sup 18}F-FDG PET/CT was 96 %, the specificity was 81 %, the positive and negative predictive values were 92 % and 89 %, respectively, and the accuracy was 91 %. PET/CT showed similar accuracy in patients with squamous cell carcinoma and in those with adenocarcinoma (P = 0.181).{sup 18}F-FDG PET/CT was more specific than CECT (67 % vs. 21 %; P < 0.0001). PET/CT was superior to CECT for the detection of nodal recurrence (P < 0.0001), but not local recurrence (P = 0.093) or distant metastases (P = 0.441). {sup 18}F-FDG PET/CT shows high accuracy in the detection of suspected recurrence in patients with oesophageal carcinoma. It is more specific than

  17. Accuracy of diagnosis criteria in patients with suspected diagnosis of sporadic Creutzfeldt-Jakob disease and detection of 14-3-3 protein, France, 1992 to 2009.

    Science.gov (United States)

    Peckeu, Laurene; Delasnerie-Lauprètre, Nicole; Brandel, Jean-Philippe; Salomon, Dominique; Sazdovitch, Véronique; Laplanche, Jean-Louis; Duyckaerts, Charles; Seilhean, Danielle; Haïk, Stéphane; Hauw, Jean-Jacques

    2017-10-01

    Diagnostic criteria of Creutzfeldt-Jakob disease (CJD), a rare and fatal transmissible nervous system disease with public health implications, are determined by clinical data, electroencephalogram (EEG), detection of 14-3-3 protein in cerebrospinal fluid (CSF), brain magnetic resonance imaging and prion protein gene examination. The specificity of protein 14-3-3 has been questioned. We reviewed data from 1,572 autopsied patients collected over an 18-year period (1992-2009) and assessed whether and how 14-3-3 detection impacted the diagnosis of sporadic CJD in France, and whether this led to the misdiagnosis of treatable disorders. 14-3-3 detection was introduced into diagnostic criteria for CJD in 1998. Diagnostic accuracy decreased from 92% for the 1992-1997 period to 85% for the 1998-2009 period. This was associated with positive detections of 14-3-3 in cases with negative EEG and alternative diagnosis at autopsy. Potentially treatable diseases were found in 163 patients (10.5%). This study confirms the usefulness of the recent modification of diagnosis criteria by the addition of the results of CSF real-time quaking-induced conversion, a method based on prion seed-induced misfolding and aggregation of recombinant prion protein substrate that has proven to be a highly specific test for diagnosis of sporadic CJD.

  18. ACCURACY ASSESSMENT OF COASTAL TOPOGRAPHY DERIVED FROM UAV IMAGES

    Directory of Open Access Journals (Sweden)

    N. Long

    2016-06-01

    Full Text Available To monitor coastal environments, Unmanned Aerial Vehicle (UAV is a low-cost and easy to use solution to enable data acquisition with high temporal frequency and spatial resolution. Compared to Light Detection And Ranging (LiDAR or Terrestrial Laser Scanning (TLS, this solution produces Digital Surface Model (DSM with a similar accuracy. To evaluate the DSM accuracy on a coastal environment, a campaign was carried out with a flying wing (eBee combined with a digital camera. Using the Photoscan software and the photogrammetry process (Structure From Motion algorithm, a DSM and an orthomosaic were produced. Compared to GNSS surveys, the DSM accuracy is estimated. Two parameters are tested: the influence of the methodology (number and distribution of Ground Control Points, GCPs and the influence of spatial image resolution (4.6 cm vs 2 cm. The results show that this solution is able to reproduce the topography of a coastal area with a high vertical accuracy (< 10 cm. The georeferencing of the DSM require a homogeneous distribution and a large number of GCPs. The accuracy is correlated with the number of GCPs (use 19 GCPs instead of 10 allows to reduce the difference of 4 cm; the required accuracy should be dependant of the research problematic. Last, in this particular environment, the presence of very small water surfaces on the sand bank does not allow to improve the accuracy when the spatial resolution of images is decreased.

  19. Data, data everywhere: detecting spatial patterns in fine-scale ecological information collected across a continent

    Science.gov (United States)

    Kevin M. Potter; Frank H. Koch; Christopher M. Oswalt; Basil V. Iannone

    2016-01-01

    Context Fine-scale ecological data collected across broad regions are becoming increasingly available. Appropriate geographic analyses of these data can help identify locations of ecological concern. Objectives We present one such approach, spatial association of scalable hexagons (SASH), whichidentifies locations where ecological phenomena occur at greater...

  20. The diagnostic accuracy of magnetic resonance venography in the detection of deep venous thrombosis: a systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Abdalla, G.; Fawzi Matuk, R.; Venugopal, V.; Verde, F.; Magnuson, T.H.; Schweitzer, M.A.; Steele, K.E.

    2015-01-01

    Aim: To search the literature for further evidence for the use of magnetic resonance venography (MRV) in the detection of suspected DVT and to re-evaluate the accuracy of MRV in the detection of suspected deep vein thrombosis (DVT). Materials and methods: PubMed, EMBASE, Scopus, Cochrane, and Web of Science were searched. Study quality and the risk of bias were evaluated using the QUADAS 2. A random effects meta-analysis including subgroup and sensitivity analyses were performed. Results: The search resulted in 23 observational studies all from academic centres. Sixteen articles were included in the meta-analysis. The summary estimates for MRV as a diagnostic non-invasive tool revealed a sensitivity of 93% (95% confidence interval [CI]: 89% to 95%) and specificity of 96% (95% CI: 94% to 97%). The heterogeneity of the studies was high. Inconsistency (I2) for sensitivity and specificity was 80.7% and 77.9%, respectively. Conclusion: Further studies investigating the use of MRV in the detection of suspected DVT did not offer further evidence to support the replacement of ultrasound with MRV as the first-line investigation. However, MRV may offer an alternative tool in the detection/diagnosis of DVT for whom ultrasound is inadequate or not feasible (such as in the obese patient). -- Highlights: •We aimed to search the literature for evidence for the use of MRV in the detection of suspected DVT. •We questioned the use of MRV in special populations like the obese where contrast venography may not be feasible or safe. •MRV may not replace ultrasound as the first-line modality for DVT detection. •Consider MRV use in special populations like the obese where other diagnostic tools are not feasible. •Studies to compare MRV vs. ultrasound as a screening tool for DVT in the obese should be considered

  1. Diagnostic accuracy of the ROCHE Septifast PCR system for the rapid detection of blood pathogens in neonatal sepsis-A prospective clinical trial.

    Science.gov (United States)

    Straub, Julia; Paula, Helga; Mayr, Michaela; Kasper, David; Assadian, Ojan; Berger, Angelika; Rittenschober-Böhm, Judith

    2017-01-01

    Diagnosis of neonatal sepsis remains a major challenge in neonatology. Most molecular-based methods are not customized for neonatal requirements. The aim of the present study was to assess the diagnostic accuracy of a modified multiplex PCR protocol for the detection of neonatal sepsis using small blood volumes. 212 episodes of suspected neonatal late onset sepsis were analyzed prospectively using the Roche SeptiFast® MGRADE PCR with a modified DNA extraction protocol and software-handling tool. Results were compared to blood culture, laboratory biomarkers and clinical signs of sepsis. Of 212 episodes, 85 (40.1%) were categorized as "not infected". Among these episodes, 1 was false positive by blood culture (1.2%) and 23 were false positive by PCR (27.1%). Of 51 (24.1%) episodes diagnosed as "culture proven sepsis", the same pathogen was detected by blood culture and PCR in 39 episodes (76.5%). In 8 episodes, more pathogens were detected by PCR compared to blood culture, and in 4 episodes the pathogen detected by blood culture was not found by PCR. One of these episodes was caused by Bacillus cereus, a pathogen not included in the PCR panel. In 76/212 (35.8%) episodes, clinical sepsis was diagnosed. Among these, PCR yielded positive results in 39.5% of episodes (30/76 episodes). For culture-positive sepsis, PCR showed a sensitivity of 90.2% (95%CI 86.2-94.2%) and a specificity of 72.9% (95%CI 67.0-79.0%). The Roche SeptiFast® MGRADE PCR using a modified DNA extraction protocol showed acceptable results for rapid detection of neonatal sepsis in addition to conventional blood culture. The benefit of rapid pathogen detection has to be balanced against the considerable risk of contamination, loss of information on antibiotic sensitivity pattern and increased costs.

  2. Meta-analysis diagnostic accuracy of SNP-based pathogenicity detection tools: a case of UTG1A1 gene mutations.

    Science.gov (United States)

    Galehdari, Hamid; Saki, Najmaldin; Mohammadi-Asl, Javad; Rahim, Fakher

    2013-01-01

    Crigler-Najjar syndrome (CNS) type I and type II are usually inherited as autosomal recessive conditions that result from mutations in the UGT1A1 gene. The main objective of the present review is to summarize results of all available evidence on the accuracy of SNP-based pathogenicity detection tools compared to published clinical result for the prediction of in nsSNPs that leads to disease using prediction performance method. A comprehensive search was performed to find all mutations related to CNS. Database searches included dbSNP, SNPdbe, HGMD, Swissvar, ensemble, and OMIM. All the mutation related to CNS was extracted. The pathogenicity prediction was done using SNP-based pathogenicity detection tools include SIFT, PHD-SNP, PolyPhen2, fathmm, Provean, and Mutpred. Overall, 59 different SNPs related to missense mutations in the UGT1A1 gene, were reviewed. Comparing the diagnostic OR, PolyPhen2 and Mutpred have the highest detection 4.983 (95% CI: 1.24 - 20.02) in both, following by SIFT (diagnostic OR: 3.25, 95% CI: 1.07 - 9.83). The highest MCC of SNP-based pathogenicity detection tools, was belong to SIFT (34.19%) followed by Provean, PolyPhen2, and Mutpred (29.99%, 29.89%, and 29.89%, respectively). Hence the highest SNP-based pathogenicity detection tools ACC, was fit to SIFT (62.71%) followed by PolyPhen2, and Mutpred (61.02%, in both). Our results suggest that some of the well-established SNP-based pathogenicity detection tools can appropriately reflect the role of a disease-associated SNP in both local and global structures.

  3. Analysis of the accuracy and precision of the McMaster method in detection of the eggs of Toxocara and Trichuris species (Nematoda) in dog faeces.

    Science.gov (United States)

    Kochanowski, Maciej; Dabrowska, Joanna; Karamon, Jacek; Cencek, Tomasz; Osiński, Zbigniew

    2013-07-01

    The aim of this study was to determine the accuracy and precision of McMaster method with Raynaud's modification in the detection of the eggs of the nematodes Toxocara canis (Werner, 1782) and Trichuris ovis (Abildgaard, 1795) in faeces of dogs. Four variants of McMaster method were used for counting: in one grid, two grids, the whole McMaster chamber and flotation in the tube. One hundred sixty samples were prepared from dog faeces (20 repetitions for each egg quantity) containing 15, 25, 50, 100, 150, 200, 250 and 300 eggs of T. canis and T. ovis in 1 g of faeces. To compare the influence of kind of faeces on the results, samples of dog faeces were enriched at the same levels with the eggs of another nematode, Ascaris suum Goeze, 1782. In addition, 160 samples of pig faeces were prepared and enriched only with A. suum eggs in the same way. The highest limit of detection (the lowest level of eggs that were detected in at least 50% of repetitions) in all McMaster chamber variants were obtained for T. canis eggs (25-250 eggs/g faeces). In the variant with flotation in the tube, the highest limit of detection was obtained for T. ovis eggs (100 eggs/g). The best results of the limit of detection, sensitivity and the lowest coefficients of variation were obtained with the use of the whole McMaster chamber variant. There was no significant impact of properties of faeces on the obtained results. Multiplication factors for the whole chamber were calculated on the basis of the transformed equation of the regression line, illustrating the relationship between the number of detected eggs and that of the eggs added to the'sample. Multiplication factors calculated for T. canis and T. ovis eggs were higher than those expected using McMaster method with Raynaud modification.

  4. Detecting spatial memory deficits beyond blindness in tg2576 Alzheimer mice.

    Science.gov (United States)

    Yassine, Nour; Lazaris, Anelise; Dorner-Ciossek, Cornelia; Després, Olivier; Meyer, Laurence; Maitre, Michel; Mensah-Nyagan, Ayikoe Guy; Cassel, Jean-Christophe; Mathis, Chantal

    2013-03-01

    The retinal degeneration Pde6b(rd1) (rd) mutation can be a major pitfall in behavioral studies using tg2576 mice bred on a B6:SJL genetic background, 1 of the most widely used models of Alzheimer's disease. After a pilot study in wild type mice, performance of 8- and 16-month-old tg2576 mice were assessed in several behavioral tasks with the challenge of selecting 1 or more task(s) showing robust memory deficits on this genetic background. Water maze acquisition was impossible in rd homozygotes, whereas Y-maze alternation, object recognition, and olfactory discrimination were unaffected by both the transgene and the rd mutation. Spatial memory retention of 8- and 16-month-old tg2576 mice, however, was dramatically affected independently of the rd mutation when mice had to recognize a spatial configuration of objects or to perform the Barnes maze. Thus, the latter tasks appear extremely useful to evaluate spatial memory deficits and to test cognitive therapies in tg2576 mice and other mouse models bred on a background susceptible to visual impairment. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Effect of spatial noise of medical grade Liquid Crystal Displays (LCD) on the detection of micro-calcification

    Science.gov (United States)

    Roehrig, Hans; Fan, Jiahua; Dallas, William J.; Krupinski, Elizabeth A.; Johnson, Jeffrey

    2009-08-01

    This presentation describes work in progress that is the result of an NIH SBIR Phase 1 project that addresses the wide- spread concern for the large number of breast-cancers and cancer victims [1,2]. The primary goal of the project is to increase the detection rate of microcalcifications as a result of the decrease of spatial noise of the LCDs used to display the mammograms [3,4]. Noise reduction is to be accomplished with the aid of a high performance CCD camera and subsequent application of local-mean equalization and error diffusion [5,6]. A second goal of the project is the actual detection of breast cancer. Contrary to the approach to mammography, where the mammograms typically have a pixel matrix of approximately 1900 x 2300 pixels, otherwise known as FFDM or Full-Field Digital Mammograms, we will only use sections of mammograms with a pixel matrix of 256 x 256 pixels. This is because at this time, reduction of spatial noise on an LCD can only be done on relatively small areas like 256 x 256 pixels. In addition, judging the efficacy for detection of breast cancer will be done using two methods: One is a conventional ROC study [7], the other is a vision model developed over several years starting at the Sarnoff Research Center and continuing at the Siemens Corporate Research in Princeton NJ [8].

  6. Noise-induced tinnitus using individualized gap detection analysis and its relationship with hyperacusis, anxiety, and spatial cognition.

    Directory of Open Access Journals (Sweden)

    Edward Pace

    Full Text Available Tinnitus has a complex etiology that involves auditory and non-auditory factors and may be accompanied by hyperacusis, anxiety and cognitive changes. Thus far, investigations of the interrelationship between tinnitus and auditory and non-auditory impairment have yielded conflicting results. To further address this issue, we noise exposed rats and assessed them for tinnitus using a gap detection behavioral paradigm combined with statistically-driven analysis to diagnose tinnitus in individual rats. We also tested rats for hearing detection, responsivity, and loss using prepulse inhibition and auditory brainstem response, and for spatial cognition and anxiety using Morris water maze and elevated plus maze. We found that our tinnitus diagnosis method reliably separated noise-exposed rats into tinnitus((+ and tinnitus((- groups and detected no evidence of tinnitus in tinnitus((- and control rats. In addition, the tinnitus((+ group demonstrated enhanced startle amplitude, indicating hyperacusis-like behavior. Despite these results, neither tinnitus, hyperacusis nor hearing loss yielded any significant effects on spatial learning and memory or anxiety, though a majority of rats with the highest anxiety levels had tinnitus. These findings showed that we were able to develop a clinically relevant tinnitus((+ group and that our diagnosis method is sound. At the same time, like clinical studies, we found that tinnitus does not always result in cognitive-emotional dysfunction, although tinnitus may predispose subjects to certain impairment like anxiety. Other behavioral assessments may be needed to further define the relationship between tinnitus and anxiety, cognitive deficits, and other impairments.

  7. Integrated circuit-based electrochemical sensor for spatially resolved detection of redox-active metabolites in biofilms.

    Science.gov (United States)

    Bellin, Daniel L; Sakhtah, Hassan; Rosenstein, Jacob K; Levine, Peter M; Thimot, Jordan; Emmett, Kevin; Dietrich, Lars E P; Shepard, Kenneth L

    2014-01-01

    Despite advances in monitoring spatiotemporal expression patterns of genes and proteins with fluorescent probes, direct detection of metabolites and small molecules remains challenging. A technique for spatially resolved detection of small molecules would benefit the study of redox-active metabolites that are produced by microbial biofilms and can affect their development. Here we present an integrated circuit-based electrochemical sensing platform featuring an array of working electrodes and parallel potentiostat channels. 'Images' over a 3.25 × 0.9 mm(2) area can be captured with a diffusion-limited spatial resolution of 750 μm. We demonstrate that square wave voltammetry can be used to detect, identify and quantify (for concentrations as low as 2.6 μM) four distinct redox-active metabolites called phenazines. We characterize phenazine production in both wild-type and mutant Pseudomonas aeruginosa PA14 colony biofilms, and find correlations with fluorescent reporter imaging of phenazine biosynthetic gene expression.

  8. Diagnostic Accuracy of CBCT with Different Voxel Sizes and Intraoral Digital Radiography for Detection of Periapical Bone Lesions: An Ex-Vivo Study

    Directory of Open Access Journals (Sweden)

    Shirin Sakhdari

    2016-10-01

    Full Text Available Objectives: This study sought to assess the diagnostic accuracy of cone beam computed tomography (CBCT with different voxel sizes and intraoral digital radiography with photostimulable phosphor (PSP plate for detection of periapical (PA bone lesions.Materials and Methods: In this ex vivo diagnostic study, one-millimeter defects were created in the alveolar sockets of 15 bone blocks, each with two posterior teeth. A no-defect control group was also included. Digital PA radiographs with PSP plates and CBCT scans with 200, 250 and 300μ voxel sizes were obtained. Four observers evaluated the possibility of lesion detection using a 5-point scale. Sensitivity, specificity, positive predictive value (PPV and negative predicative value (NPV were analyzed using one-way ANOVA and Tamhane’s post hoc test. Kappa and weighted kappa statistics were applied to assess intraobserver and interobserver agreements.Results: Cochrane Q test showed no significant difference between PSP and CBCT imaging modalities in terms of kappa and weighted kappa statistics (P=0.675. The complete sensitivity and complete NPV for 200 and 250 μ voxel sizes were higher than those of 300 μ voxel size and digital radiography (P<0.001. No significant difference was noted in other parameters among other imaging modalities (P=0.403.Conclusions: The results showed that high-resolution CBCT scans had higher diagnostic accuracy than PSP digital radiography for detection of artificially created PA bone lesions. Voxel size (field of view must be taken into account to minimize patient radiation dose.Keywords: Diagnosis; Cone-Beam Computed Tomography; Radiography, Dental, Digital; Periapical Periodontitis

  9. Detecting spatial patterns with the cumulant function – Part 2: An application to El Niño

    Directory of Open Access Journals (Sweden)

    P. Yiou

    2008-02-01

    Full Text Available The spatial coherence of a measured variable (e.g. temperature or pressure is often studied to determine the regions of high variability or to find teleconnections, i.e. correlations between specific regions. While usual methods to find spatial patterns, such as Principal Components Analysis (PCA, are constrained by linear symmetries, the dependence of variables such as temperature or pressure at different locations is generally nonlinear. In particular, large deviations from the sample mean are expected to be strongly affected by such nonlinearities. Here we apply a newly developed nonlinear technique (Maxima of Cumulant Function, MCF for detection of typical spatial patterns that largely deviate from the mean. In order to test the technique and to introduce the methodology, we focus on the El Niño/Southern Oscillation and its spatial patterns. We find nonsymmetric temperature patterns corresponding to El Niño and La Niña, and we compare the results of MCF with other techniques, such as the symmetric solutions of PCA, and the nonsymmetric solutions of Nonlinear PCA (NLPCA. We found that MCF solutions are more reliable than the NLPCA fits, and can capture mixtures of principal components. Finally, we apply Extreme Value Theory on the temporal variations extracted from our methodology. We find that the tails of the distribution of extreme temperatures during La Niña episodes is bounded, while the tail during El Niños is less likely to be bounded. This implies that the mean spatial patterns of the two phases are asymmetric, as well as the behaviour of their extremes.

  10. Dynamic contrast-enhanced MRI improves accuracy for detecting focal splenic involvement in children and adolescents with Hodgkin disease

    Energy Technology Data Exchange (ETDEWEB)

    Punwani, Shonit; Taylor, Stuart A.; Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); University College London Hospital, Department of Radiology, London (United Kingdom); Cheung, King Kenneth; Skipper, Nicholas [University College London, Centre for Medical Imaging, London (United Kingdom); Bell, Nichola; Humphries, Paul D. [University College London Hospital, Department of Radiology, London (United Kingdom); Bainbridge, Alan [University College London, Department of Medical Physics and Bioengineering, London (United Kingdom); Groves, Ashley M.; Hain, Sharon F.; Ben-Haim, Simona [University College Hospital, Institute of Nuclear Medicine, London (United Kingdom); Shankar, Ananth; Daw, Stephen [University College London Hospital, Department of Paediatrics, London (United Kingdom)

    2013-08-15

    Accurate assessment of splenic disease is important for staging Hodgkin lymphoma. The purpose of this study was to assess T2-weighted imaging with and without dynamic contrast-enhanced (DCE) MRI for evaluation of splenic Hodgkin disease. Thirty-one children with Hodgkin lymphoma underwent whole-body T2-weighted MRI with supplementary DCE splenic imaging, and whole-body PET-CT before and following chemotherapy. Two experienced nuclear medicine physicians derived a PET-CT reference standard for splenic disease, augmented by follow-up imaging. Unaware of the PET-CT, two experienced radiologists independently evaluated MRI exercising a locked sequential read paradigm (T2-weighted then DCE review) and recorded the presence/absence of splenic disease at each stage. Performance of each radiologist was determined prior to and following review of DCE-MRI. Incorrect MRI findings were ascribed to reader (lesion present on MRI but missed by reader) or technical (lesion not present on MRI) error. Seven children had splenic disease. Sensitivity/specificity of both radiologists for the detection of splenic involvement using T2-weighted images alone was 57%/100% and increased to 100%/100% with DCE-MRI. There were three instances of technical error on T2-weighted imaging; all lesions were visible on DCE-MRI. T2-weighted imaging when complemented by DCE-MRI imaging may improve evaluation of Hodgkin disease splenic involvement. (orig.)

  11. Dynamic contrast-enhanced MRI improves accuracy for detecting focal splenic involvement in children and adolescents with Hodgkin disease

    International Nuclear Information System (INIS)

    Punwani, Shonit; Taylor, Stuart A.; Halligan, Steve; Cheung, King Kenneth; Skipper, Nicholas; Bell, Nichola; Humphries, Paul D.; Bainbridge, Alan; Groves, Ashley M.; Hain, Sharon F.; Ben-Haim, Simona; Shankar, Ananth; Daw, Stephen

    2013-01-01

    Accurate assessment of splenic disease is important for staging Hodgkin lymphoma. The purpose of this study was to assess T2-weighted imaging with and without dynamic contrast-enhanced (DCE) MRI for evaluation of splenic Hodgkin disease. Thirty-one children with Hodgkin lymphoma underwent whole-body T2-weighted MRI with supplementary DCE splenic imaging, and whole-body PET-CT before and following chemotherapy. Two experienced nuclear medicine physicians derived a PET-CT reference standard for splenic disease, augmented by follow-up imaging. Unaware of the PET-CT, two experienced radiologists independently evaluated MRI exercising a locked sequential read paradigm (T2-weighted then DCE review) and recorded the presence/absence of splenic disease at each stage. Performance of each radiologist was determined prior to and following review of DCE-MRI. Incorrect MRI findings were ascribed to reader (lesion present on MRI but missed by reader) or technical (lesion not present on MRI) error. Seven children had splenic disease. Sensitivity/specificity of both radiologists for the detection of splenic involvement using T2-weighted images alone was 57%/100% and increased to 100%/100% with DCE-MRI. There were three instances of technical error on T2-weighted imaging; all lesions were visible on DCE-MRI. T2-weighted imaging when complemented by DCE-MRI imaging may improve evaluation of Hodgkin disease splenic involvement. (orig.)

  12. Detection of Tuberculosis Infection Hotspots Using Activity Spaces Based Spatial Approach in an Urban Tokyo, from 2003 to 2011.

    Directory of Open Access Journals (Sweden)

    Kiyohiko Izumi

    Full Text Available Identifying ongoing tuberculosis infection sites is crucial for breaking chains of transmission in tuberculosis-prevalent urban areas. Previous studies have pointed out that detection of local accumulation of tuberculosis patients based on their residential addresses may be limited by a lack of matching between residences and tuberculosis infection sites. This study aimed to identify possible tuberculosis hotspots using TB genotype clustering statuses and a concept of "activity space", a place where patients spend most of their waking hours. We further compared the spatial distribution by different residential statuses and describe urban environmental features of the detected hotspots.Culture-positive tuberculosis patients notified to Shinjuku city from 2003 to 2011 were enrolled in this case-based cross-sectional study, and their demographic and clinical information, TB genotype clustering statuses, and activity space were collected. Spatial statistics (Global Moran's I and Getis-Ord Gi* statistics identified significant hotspots in 152 census tracts, and urban environmental features and tuberculosis patients' characteristics in these hotspots were assessed.Of the enrolled 643 culture-positive tuberculosis patients, 416 (64.2% were general inhabitants, 42 (6.5% were foreign-born people, and 184 were homeless people (28.6%. The percentage of overall genotype clustering was 43.7%. Genotype-clustered general inhabitants and homeless people formed significant hotspots around a major railway station, whereas the non-clustered general inhabitants formed no hotspots. This suggested the detected hotspots of activity spaces may reflect ongoing tuberculosis transmission sites and were characterized by smaller residential floor size and a higher proportion of non-working households.Activity space-based spatial analysis suggested possible TB transmission sites around the major railway station and it can assist in further comprehension of TB transmission

  13. Detection of Tuberculosis Infection Hotspots Using Activity Spaces Based Spatial Approach in an Urban Tokyo, from 2003 to 2011.

    Science.gov (United States)

    Izumi, Kiyohiko; Ohkado, Akihiro; Uchimura, Kazuhiro; Murase, Yoshiro; Tatsumi, Yuriko; Kayebeta, Aya; Watanabe, Yu; Ishikawa, Nobukatsu

    2015-01-01

    Identifying ongoing tuberculosis infection sites is crucial for breaking chains of transmission in tuberculosis-prevalent urban areas. Previous studies have pointed out that detection of local accumulation of tuberculosis patients based on their residential addresses may be limited by a lack of matching between residences and tuberculosis infection sites. This study aimed to identify possible tuberculosis hotspots using TB genotype clustering statuses and a concept of "activity space", a place where patients spend most of their waking hours. We further compared the spatial distribution by different residential statuses and describe urban environmental features of the detected hotspots. Culture-positive tuberculosis patients notified to Shinjuku city from 2003 to 2011 were enrolled in this case-based cross-sectional study, and their demographic and clinical information, TB genotype clustering statuses, and activity space were collected. Spatial statistics (Global Moran's I and Getis-Ord Gi* statistics) identified significant hotspots in 152 census tracts, and urban environmental features and tuberculosis patients' characteristics in these hotspots were assessed. Of the enrolled 643 culture-positive tuberculosis patients, 416 (64.2%) were general inhabitants, 42 (6.5%) were foreign-born people, and 184 were homeless people (28.6%). The percentage of overall genotype clustering was 43.7%. Genotype-clustered general inhabitants and homeless people formed significant hotspots around a major railway station, whereas the non-clustered general inhabitants formed no hotspots. This suggested the detected hotspots of activity spaces may reflect ongoing tuberculosis transmission sites and were characterized by smaller residential floor size and a higher proportion of non-working households. Activity space-based spatial analysis suggested possible TB transmission sites around the major railway station and it can assist in further comprehension of TB transmission dynamics in an

  14. Fast EEG spike detection via eigenvalue analysis and clustering of spatial amplitude distribution

    Science.gov (United States)

    Fukami, Tadanori; Shimada, Takamasa; Ishikawa, Bunnoshin

    2018-06-01

    Objective. In the current study, we tested a proposed method for fast spike detection in electroencephalography (EEG). Approach. We performed eigenvalue analysis in two-dimensional space spanned by gradients calculated from two neighboring samples to detect high-amplitude negative peaks. We extracted the spike candidates by imposing restrictions on parameters regarding spike shape and eigenvalues reflecting detection characteristics of individual medical doctors. We subsequently performed clustering, classifying detected peaks by considering the amplitude distribution at 19 scalp electrodes. Clusters with a small number of candidates were excluded. We then defined a score for eliminating spike candidates for which the pattern of detected electrodes differed from the overall pattern in a cluster. Spikes were detected by setting the score threshold. Main results. Based on visual inspection by a psychiatrist experienced in EEG, we evaluated the proposed method using two statistical measures of precision and recall with respect to detection performance. We found that precision and recall exhibited a trade-off relationship. The average recall value was 0.708 in eight subjects with the score threshold that maximized the F-measure, with 58.6  ±  36.2 spikes per subject. Under this condition, the average precision was 0.390, corresponding to a false positive rate 2.09 times higher than the true positive rate. Analysis of the required processing time revealed that, using a general-purpose computer, our method could be used to perform spike detection in 12.1% of the recording time. The process of narrowing down spike candidates based on shape occupied most of the processing time. Significance. Although the average recall value was comparable with that of other studies, the proposed method significantly shortened the processing time.

  15. Land cover mapping and change detection in urban watersheds using QuickBird high spatial resolution satellite imagery

    Science.gov (United States)

    Hester, David Barry

    The objective of this research was to develop methods for urban land cover analysis using QuickBird high spatial resolution satellite imagery. Such imagery has emerged as a rich commercially available remote sensing data source and has enjoyed high-profile broadcast news media and Internet applications, but methods of quantitative analysis have not been thoroughly explored. The research described here consists of three studies focused on the use of pan-sharpened 61-cm spatial resolution QuickBird imagery, the spatial resolution of which is the highest of any commercial satellite. In the first study, a per-pixel land cover classification method is developed for use with this imagery. This method utilizes a per-pixel classification approach to generate an accurate six-category high spatial resolution land cover map of a developing suburban area. The primary objective of the second study was to develop an accurate land cover change detection method for use with QuickBird land cover products. This work presents an efficient fuzzy framework for transforming map uncertainty into accurate and meaningful high spatial resolution land cover change analysis. The third study described here is an urban planning application of the high spatial resolution QuickBird-based land cover product developed in the first study. This work both meaningfully connects this exciting new data source to urban watershed management and makes an important empirical contribution to the study of suburban watersheds. Its analysis of residential roads and driveways as well as retail parking lots sheds valuable light on the impact of transportation-related land use on the suburban landscape. Broadly, these studies provide new methods for using state-of-the-art remote sensing data to inform land cover analysis and urban planning. These methods are widely adaptable and produce land cover products that are both meaningful and accurate. As additional high spatial resolution satellites are launched and the

  16. Comparison of machine-learning algorithms to build a predictive model for detecting undiagnosed diabetes - ELSA-Brasil: accuracy study.

    Science.gov (United States)

    Olivera, André Rodrigues; Roesler, Valter; Iochpe, Cirano; Schmidt, Maria Inês; Vigo, Álvaro; Barreto, Sandhi Maria; Duncan, Bruce Bartholow

    2017-01-01

    Type 2 diabetes is a chronic disease associated with a wide range of serious health complications that have a major impact on overall health. The aims here were to develop and validate predictive models for detecting undiagnosed diabetes using data from the Longitudinal Study of Adult Health (ELSA-Brasil) and to compare the performance of different machine-learning algorithms in this task. Comparison of machine-learning algorithms to develop predictive models using data from ELSA-Brasil. After selecting a subset of 27 candidate variables from the literature, models were built and validated in four sequential steps: (i) parameter tuning with tenfold cross-validation, repeated three times; (ii) automatic variable selection using forward selection, a wrapper strategy with four different machine-learning algorithms and tenfold cross-validation (repeated three times), to evaluate each subset of variables; (iii) error estimation of model parameters with tenfold cross-validation, repeated ten times; and (iv) generalization testing on an independent dataset. The models were created with the following machine-learning algorithms: logistic regression, artificial neural network, naïve Bayes, K-nearest neighbor and random forest. The best models were created using artificial neural networks and logistic regression. -These achieved mean areas under the curve of, respectively, 75.24% and 74.98% in the error estimation step and 74.17% and 74.41% in the generalization testing step. Most of the predictive models produced similar results, and demonstrated the feasibility of identifying individuals with highest probability of having undiagnosed diabetes, through easily-obtained clinical data.

  17. Diagnostic accuracy study of a factor VIII ELISA for detection of factor VIII antibodies in congenital and acquired haemophilia A.

    Science.gov (United States)

    Batty, Paul; Moore, Gary W; Platton, Sean; Maloney, James C; Palmer, Ben; Bowles, Louise; Pasi, K John; Rangarajan, Savita; Hart, Daniel P

    2015-10-01

    Antibody formation to factor VIII (FVIII) remains the greatest clinical and diagnostic challenge to the haemophilia-treating physician. Current guidance for testing for inhibitory FVIII antibodies (inhibitors) recommends the functional Nijmegen-Bethesda assay (NBA). A FVIII ELISA offers a complementary, immunological approach for FVIII antibody testing. It was the aim of this study to retrospectively evaluate the performance of a FVIII ELISA (index) for detection of FVIII antibodies, compared with the NBA (reference). All samples sent for routine FVIII antibody testing at two haemophilia Comprehensive Care Centres, were tested in parallel using the NBA and a solid-phase, indirect FVIII ELISA kit (Immucor). A total of 497 samples from 239 patients (severe haemophilia A=140, non-severe haemophilia A=85, acquired haemophilia A=14) were available for analysis. Sixty-three samples tested positive by the NBA (prevalence 12.7%, 95% confidence interval [CI], 9.9-15.9 %), with a median inhibitor titre of 1.2 BU/ml (range 0.7-978.0). The FVIII ELISA demonstrated a specificity of 94.0% (95%CI, 91.3-96.0), sensitivity of 77.8% (95%CI, 65.5-87.3), negative predictive value of 96.7% (95%CI, 94.5-98.2), positive predictive value 65.3% (95%CI, 53.5-76.0), negative likelihood ratio 0.2 (95%CI, 0.1-0.4), positive likelihood ratio 13.0 (95%CI, 8.7-19.3) and a diagnostic odds ratio of 54.9 (95%CI, 27.0-112.0). Strong positive correlation (r=0.77, pNBA (log adjusted) and FVIII ELISA optical density. In conclusion, FVIII ELISA offers a simple, specific, surveillance method enabling batch testing of non-urgent samples for the presence of FVIII antibodies.

  18. The Accuracy of the Sysmex UF-1000i in Urine Bacterial Detection Compared With the Standard Urine Analysis and Culture.

    Science.gov (United States)

    Erdman, Patrick; Anderson, Brian; Zacko, J Christopher; Taylor, Kirk; Donaldson, Keri

    2017-11-01

    - Urinary tract infections are characterized by the presence of microbial pathogens within the urinary tract. They represent one of the most common infections in hospitalized and clinic patients. - To model the parameters of the Sysmex UF-1000i to the gold standard, urine culture, and to compare the detection of dipstick leukocyte esterase and nitrates to urine cultures and UF-1000i results. - Data were compared from urine samples collected in sterile containers for bacterial culture and microscopic analysis. One sample was used to inoculate a 5% sheep blood agar and MacConkey agar plate using a 0.001-mL calibrated loop. The second sample was analyzed by urinalysis-associated microscopy. The media plates were investigated for growth after 18 to 24 hours of aerobic incubation at 37°C. The second sample was analyzed for bacteria and leukocytes with the Sysmex UF-1000i according to the manufacturer's guidelines. Three definitions for culture results, sensitivity, and specificity at different cutoff values were calculated for the UF-1000i. - The negative predictive value for any positive culture in the adult population included in the study was 95.5%, and the negative predictive value for positive cultures containing growth of 100 000 or more colony-forming units was 99.3% using the Sysmex UF-1000i. - Sysmex UF-1000i showed 98% sensitivity and 93.7% specificity with a 95.5% negative predictive value. Thus, a negative screen with the UF-1000i using defined thresholds for white blood cell counts and bacteria was likely to be a true negative, decreasing the need for presumptive antibiotics.

  19. Sensitivity and accuracy of thallium-201 myocardial scintigraphy in the detection of coronary artery and myocardial disease

    International Nuclear Information System (INIS)

    Loesse, B.; Kroenert, H.; Rafflenbeul, D.; Feinendegen, L.E.; Loogen, F.; Duesseldorf Univ.

    1979-01-01

    169 patients (154 men, 15 women, mean age 49.5 years, range 27 to 64 years) were studied by means of 201-Thallium myocardial scintigraphy (201-Tl) and coronary angiography. According to the coronarangiogram, 130 patients had coronary artery disease (CAD): 53 a 1-vessel CAD, 29 a 2-vessel CAD, 48 a 3-vessel CAD. 39 patients had normal or less than 50% stenosed coronary arteries, but only 13 of these patients had also a normal ventriculogram, whereas 26 had an abnormal ventriculogram with local hypo-, a- or dyskinesia, diffuse hypokinesia, dilatation, or marked hypertrophy. The ramus interventicularis anterior (RIVA) was involved (stenosis of more than 50%) in 117 cases, the ramus circumflexus (R. circ.) in 70 cases, and the right coronary artery (RCA) in 67 cases. 201-Tl was abnormal in 98% of all 130 patients with CAD, in 100% of 93 patients with prior infarction, and in 95% of 37 patients without prior infarction. The sensitivity of the rest and/or exercise ECG in the same patients was only 79%, 88% and 57%, respectively. 201-Tl was abnormal in all 26 patients with a pathologic ventriculogram in spite of normal coronary arteries. 201-Tl and ECG were normal in only 9 of the 13 patients (=69%) with normal coronary arteries and normal ventriculogram. Myocardial biopsy, however, performed in 2 of the other 4 patients disclosed in part severe degenerative changes which can possibly explain the abnormal findings of 201-Tl and ECG. Significantly, i.e. more than 50% stenosed RIVA was correctly detected by 201-Tl in 98%, R. circ. in 71%, and RCA in 91% of the cases. The specificity of 201-Tl was limited by the great number of patients with a pathologic ventriculogram combined with normal coronary arteries. (orig.) [de

  20. Multi-wavelength spectrophotometric analysis for detection of xanthochromia in cerebrospinal fluid and accuracy for the diagnosis of subarachnoid hemorrhage.

    Science.gov (United States)

    Smith, Andrew; Wu, Alan H B; Lynch, Kara L; Ko, Nerissa; Grenache, David G

    2013-09-23

    Cerebrospinal fluid (CSF) was examined for bilirubin, an important indicator for diagnosis of subarachnoid hemorrhage (SAH). A multi-wavelength (340, 415, and 460 nm) spectrophotometric assay was developed for the quantitative measurement of bilirubin in CSF, enabling the mathematical correction for absorbance of hemoglobin and proteins. Bilirubin and hemoglobin results were correlated to HPLC and a standard colorimetric assay, respectively. A subset of samples was sent for an absorbance reading at 450 nm following baseline correction. The multi-wavelength bilirubin assay was validated on 70 patients with confirmed SAH and 70 patients with neurologic symptoms who ruled out for SAH. The multi-wavelength spectrophometric assay demonstrated no interferences due to proteins (albumin) up to 30 g/l or oxyhemoglobin up to 260 mg/l. The assay limit of detection was 0.2 mg/l, linear to 20 mg/l, and CVs ranged from 1 to 6% at bilirubin concentrations of 0.84 and 2.1mg/l. The spectrophotometric assay correlated to HPLC and the colorimetric assay for bilirubin and hemoglobin, respectively. Results also correlated to the absorbance method (with removal of samples with high hemoglobin and proteins). The area under the ROC curve for diagnosis of SAH was 0.971 and 0.954 for the HPLC and spectrophotometric assay, respectively. At a cutoff of 0.2mg/l, the clinical specificity was 100% for both assays, and the clinical sensitivity was 94.3% and 88.6% for SAH for the HPLC and spectrophotometric asays, respectively. The multi-wavelength spectrophotometric assay is an objective alternative to visual inspection, HPLC, and absorbance for CSF bilirubin. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Accuracy of the Enhanced Liver Fibrosis Test vs FibroTest, Elastography, and Indirect Markers in Detection of Advanced Fibrosis in Patients With Alcoholic Liver Disease.

    Science.gov (United States)

    Thiele, Maja; Madsen, Bjørn Stæhr; Hansen, Janne Fuglsang; Detlefsen, Sönke; Antonsen, Steen; Krag, Aleksander

    2018-04-01

    Alcohol is the leading cause of cirrhosis and liver-related mortality, but we lack serum markers to detect compensated disease. We compared the accuracy of the Enhanced Liver Fibrosis test (ELF), the FibroTest, liver stiffness measurements (made by transient elastography and 2-dimensional shear-wave elastography), and 6 indirect marker tests in detection of advanced liver fibrosis (Kleiner stage ≥F3). We performed a prospective study of 10 liver fibrosis markers (patented and not), all performed on the same day. Patients were recruited from primary centers (municipal alcohol rehabilitation, n = 128; 6% with advanced fibrosis) and secondary health care centers (hospital outpatient clinics, n = 161; 36% with advanced fibrosis) in the Region of Southern Denmark from 2013 through 2016. Biopsy-verified fibrosis stage was used as the reference standard. The primary aim was to validate ELF in detection of advanced fibrosis in patients with alcoholic liver disease recruited from primary and secondary health care centers, using the literature-based cutoff value of 10.5. Secondary aims were to assess the diagnostic accuracy of ELF for significant fibrosis and cirrhosis and to determine whether combinations of fibrosis markers increase diagnostic yield. The ELF identified patients with advanced liver fibrosis with an area under the receiver operating characteristic curve (AUROC) of 0.92 (95% confidence interval 0.89-0.96); findings did not differ significantly between patients from primary vs secondary care (P = .917). ELF more accurately identified patients with advanced liver fibrosis than indirect marker tests, but ELF and FibroTest had comparable diagnostic accuracies (AUROC of FibroTest, 0.90) (P = .209 for comparison with ELF). Results from the ELF and FibroTest did not differ significantly from those of liver stiffness measurement in intention-to-diagnose analyses (AUROC for transient elastography, 0.90), but did differ in the per-protocol analysis (AUROC for

  2. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    International Nuclear Information System (INIS)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele; Liga, Riccardo; Marzullo, Paolo

    2015-01-01

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronary stenosis >70 % was considered significant. In every patient, the summed difference score (SDS) was computed from MPI images. Patients were categorized according to the tertiles of the distribution of individual HRR during dipyridamole: ''Group 1'' (HRR < 8 bpm; lowest tertile); ''Group 2'' (8 ≤ HRR ≤ 12 bpm; middle tertile); ''Group 3'' (HRR >12 bpm; highest tertile). Significant coronary artery disease (CAD) was present in 102 (62 %) patients. In the overall population, MPI showed a significant accuracy (AUC: 0.81, 95 % CI 0.74-0.86; p < 0.001) in unmasking the presence of significant coronary stenosis. Interestingly, in patients with a blunted HRR during dipyridamole (''Group 1'') MPI showed a significantly lower sensitivity (68 %) in detecting CAD than in those with a higher HRR (''Group 3'') (91 %, p = 0.007), despite a preserved specificity (76 % vs 77 %, P=NS). Similarly, the correlation among CAD extent and post-stress LV functional stunning was limited to ''Group 3'' patients, while it disappeared in those with blunted HRR. In patients with suspected IHD, MPI sensitivity is strongly influenced by the magnitude of patient heart rate increase to the pharmacologic stressor, suggesting an interaction among blunted HRR and lower accuracy in unmasking CAD. (orig.)

  3. Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes.

    Science.gov (United States)

    Seifi, Sohila; Khatony, Alireza; Moradi, Gholamreza; Abdi, Alireza; Najafi, Farid

    2018-01-01

    Heart surgery patients are more at risk of poor peripheral perfusion, and peripheral capillary oxygen saturation (SpO2) measurement is regular care for continuous analysis of blood oxygen saturation in these patients. With regard to controversial studies on accuracy of the current pulse oximetry probes and lack of data related to patients undergoing heart surgery, the present study was conducted to determine accuracy of pulse oximetry probes of finger, toe, forehead and earlobe in detection of oxygen saturation in patients admitted to intensive care units for coronary artery bypass surgery. In this clinical trial, 67 patients were recruited based on convenience sampling method among those admitted to intensive care units for coronary artery bypass surgery. The SpO2 value was measured using finger, toe, forehead and earlobe probes and then compared with the standard value of arterial oxygen saturation (SaO2). Data were entered into STATA-11 software and analyzed using descriptive, inferential and Bland-Altman statistical analyses. Highest and lowest correlational mean values of SpO2 and SaO2 were related to finger and earlobe probes, respectively. The highest and lowest agreement of SpO2 and SaO2 were related to forehead and earlobe probes. The SpO2 of earlobe probes due to lesser mean difference, more limited confidence level and higher agreement ration with SaO2 resulted by arterial blood gas (ABG) analysis had higher accuracy. Thus, it is suggested to use earlobe probes in patients admitted to the intensive care unit for coronary artery bypass surgery. Registration of this trial protocol has been approved in Iranian Registry of Clinical Trials at 2018-03-19 with reference IRCT20100913004736N22. "Retrospectively registered."

  4. Chronotropic response to vasodilator-stress in patients submitted to myocardial perfusion imaging: impact on the accuracy in detecting coronary stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Gimelli, Alessia; Coceani, Michele; Quaranta, Angela; Emdin, Michele [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); Liga, Riccardo [University Hospital of Pisa, Cardio-Thoracic and Vascular Department, Pisa (Italy); Marzullo, Paolo [Fondazione Toscana Gabriele Monasterio, Pisa (Italy); CNR, Institute of Clinical Physiology, Pisa (Italy)

    2015-11-15

    A lower heart rate response (HRR) during vasodilator MPI has been shown to have a relevant adverse prognostic impact. We sought to evaluate the interaction among individual HRR to vasodilator stress and myocardial perfusion imaging (MPI) accuracy in patients with suspected ischemic heart disease (IHD). One hundred and sixty-five consecutive patients were submitted to vasodilator-stress MPI on a cardiac camera equipped with cadmium-zinc-thelluride detectors and coronary angiography. A coronar