WorldWideScience

Sample records for spacer device utilizing

  1. Spacer device for nuclear reactor fuel elements

    International Nuclear Information System (INIS)

    Anthony, A.J.; Gaines, A.L.; Krawiec, D.M.

    1974-01-01

    The grid-type spacer device consists of two rows of main spacers arranged parallel to each other with some space in between, the first row extending perpendicular to the second row. Parallel to the respective rows of main spacers there are rows of secondary spacers interlocked with the main spacers. The individual spacers are welded together at their points of intersection. A large number of spring cages are installed within the spacer device to hold in place the main spacers which are oriented at right angles relative to each other. In addition, the spring cages serve for supporting the fuel elements. The spacers are made of zirconium which does not greatly influence the neutron capture cross section of the reactor. The material of the spring cages with the spring elements is a nickel alloy. It has the necessary stress relaxation properties to be able to force the fuel elements against the spacers under the action of the spring. (DG) [de

  2. Feasibility Study of Interactive Game Technologies to Improve Experience with Inhaler Spacer Devices in Young Children

    OpenAIRE

    Aslam, Tariq; Shakir, Savana; Murray, Clare

    2016-01-01

    IntroductionThe correct use of inhaler devices with facemasks and spacers in young children can be difficult for both children and parents, resulting in distress for both, poor adherence and ineffective drug delivery. The aim of this study was to develop and assess the utility and impact of an interactive electronic game designed to improve the experience of spacer devices in young asthmatic children.MethodsThe Respiratory Aid For Inhaler (RAFIhaler) technology consists of a smartphone mounte...

  3. Knowledge of spacer device, peak flow meter and inhaler technique ...

    African Journals Online (AJOL)

    Background: Metered dose inhalers are cornerstone in effective management of bronchial asthma when correctly used. Most studies hitherto have focused on assessing patient's knowledge of inhaler technique. We sought to assess the knowledge of inhaler technique, spacer device and peak flow meter among doctors and ...

  4. Dark current of organic heterostructure devices with insulating spacer layers

    Science.gov (United States)

    Yin, Sun; Nie, Wanyi; Mohite, Aditya D.; Saxena, Avadh; Smith, Darryl L.; Ruden, P. Paul

    2015-03-01

    The dark current density at fixed voltage bias in donor/acceptor organic planar heterostructure devices can either increase or decrease when an insulating spacer layer is added between the donor and acceptor layers. The dominant current flow process in these systems involves the formation and subsequent recombination of an interfacial exciplex state. If the exciplex formation rate limits current flow, the insulating interface layer can increase dark current whereas, if the exciplex recombination rate limits current flow, the insulating interface layer decreases dark current. We present a device model to describe this behavior and illustrate it experimentally for various donor/acceptor systems, e.g. P3HT/LiF/C60.

  5. Manipulation of recombination zone by utilizing the donor of electroplex as a spacer

    Energy Technology Data Exchange (ETDEWEB)

    Lü, Zhaoyue, E-mail: lvzhaoyue@ecust.edu.cn [Department of Physics, School of Science, East China University of Science & Technology, Shanghai 200237 (China); Yin, Yuehong [Department of Applied Physics, Institute of Physical Chemistry, Henan Polytechnic University, Jiaozuo, Henan Province 454000 (China); Xiao, Jing [Physics and Electronic Engineering College, Taishan University, Shandong Province 271021,China (China)

    2016-11-15

    The emission of electroplex is varied with applied voltages, leading to poor color stability of devices. In this work, the recombination region was investigated in organic light-emitting diodes (OLEDs) based on the electroplex between N,N’-diphenyl-N,N’-bis(1-naphthyl-phenyl)-1,1′-biphenyl-4,4′-diamine(NPB) and 2-(4-biphenylyl)-5-(4-tert-butylphenyl)-1,2,4-oxadiazole (PBD). Color stability was manipulated by introducing the donor of electroplex as a spacer, which plays an important role of recombination zone for electroplex-based OLEDs. The 5-nm-spacer-device brought out a tolerable chromaticity coordinate shift of less than 0.01 for both x- and y-value. White light emission with CIE coordinates of (0.37,0.28) and (0.33,0.26) at 12 V was achieved when the thickness of spacer was 7 and 10 nm, respectively. The 7-nm-spacer-device exhibited better color stability than the 10-nm-spacer-device. This proves that adjusting spacer thickness is a simple and efficient method to control recombination region and can be useful for fulfilling color-stable electroplex-based white emission.

  6. Manipulation of recombination zone by utilizing the donor of electroplex as a spacer

    International Nuclear Information System (INIS)

    Lü, Zhaoyue; Yin, Yuehong; Xiao, Jing

    2016-01-01

    The emission of electroplex is varied with applied voltages, leading to poor color stability of devices. In this work, the recombination region was investigated in organic light-emitting diodes (OLEDs) based on the electroplex between N,N’-diphenyl-N,N’-bis(1-naphthyl-phenyl)-1,1′-biphenyl-4,4′-diamine(NPB) and 2-(4-biphenylyl)-5-(4-tert-butylphenyl)-1,2,4-oxadiazole (PBD). Color stability was manipulated by introducing the donor of electroplex as a spacer, which plays an important role of recombination zone for electroplex-based OLEDs. The 5-nm-spacer-device brought out a tolerable chromaticity coordinate shift of less than 0.01 for both x- and y-value. White light emission with CIE coordinates of (0.37,0.28) and (0.33,0.26) at 12 V was achieved when the thickness of spacer was 7 and 10 nm, respectively. The 7-nm-spacer-device exhibited better color stability than the 10-nm-spacer-device. This proves that adjusting spacer thickness is a simple and efficient method to control recombination region and can be useful for fulfilling color-stable electroplex-based white emission.

  7. Device for a nuclear reactor. [Fuel element spacers

    Energy Technology Data Exchange (ETDEWEB)

    Foulds, R B; Kasberg, A H; Puechl, K H; Bleiberg, M L

    1972-03-08

    A spacer design for fuel element clusters for PWR type reactors is described. It consists of a frame supporting an egg-carton like grid each sector of which is provided with springs which grip the fuel pins. The spring design is such as to prevent fuel pin vibrations and at same time accommodate fuel pin deformations. Formulae for the calculation of natural frequencies, spring stiffness and friction loads are presented.

  8. Efficient and colour-stable hybrid white organic light-emitting diodes utilizing electron-hole balanced spacers

    Energy Technology Data Exchange (ETDEWEB)

    Leem, Dong-Seok; Kim, Ji Whan; Kim, Jang-Joo [Department of Materials Science and Engineering, and OLED Center, Seoul National University, Seoul 151-744 (Korea, Republic of); Jung, Sung Ouk; Kim, Seul-Ong; Kwon, Soon-Ki [School of Materials Science and Engineering, and Engineering Research Institute (ERI), Gyeongsang National University, Jinju 660-701 (Korea, Republic of); Kim, Se Hoon; Kim, Kee Young [Dongwoo Fine-Chem Co., Ltd, Pyeongtaek 451-822 (Korea, Republic of); Kim, Yun-Hi, E-mail: jjkim@snu.ac.k, E-mail: skwon@gnu.ac.k [Department of Chemistry and RINS, Gyeongsang National University, Jinju 660-701 (Korea, Republic of)

    2010-10-13

    High-efficiency two-colour white organic light-emitting diodes (WOLEDs) comprising a newly synthesized iridium complex orange phosphor ((impy){sub 2}Ir(acac)) and a blue fluorophor (BD012) have been realized by placing several kinds of thin spacers between two emitters. Hybrid WOLEDs with a spacer composed of a hole-transporting N,N-dicarbazolyl-3,5-benzene (mCP) and an electron-transporting 4,7-diphenyl-1,10-phenanthroline (Bphen) exhibit a high external quantum efficiency (EQE) of up to 8.4% and a negligible colour change (the colour coordinate of (0.39, 0.41) at 1000 cd m{sup -2}) with increasing brightness, whereas the device using a hole-transporting mCP spacer shows a relatively low EQE of 6.2% and a large shift of emitting colour with increasing brightness. Device performance is further characterized based on the charge transport behaviour of the spacers inserted between the two emitters.

  9. Efficient and colour-stable hybrid white organic light-emitting diodes utilizing electron-hole balanced spacers

    International Nuclear Information System (INIS)

    Leem, Dong-Seok; Kim, Ji Whan; Kim, Jang-Joo; Jung, Sung Ouk; Kim, Seul-Ong; Kwon, Soon-Ki; Kim, Se Hoon; Kim, Kee Young; Kim, Yun-Hi

    2010-01-01

    High-efficiency two-colour white organic light-emitting diodes (WOLEDs) comprising a newly synthesized iridium complex orange phosphor ((impy) 2 Ir(acac)) and a blue fluorophor (BD012) have been realized by placing several kinds of thin spacers between two emitters. Hybrid WOLEDs with a spacer composed of a hole-transporting N,N-dicarbazolyl-3,5-benzene (mCP) and an electron-transporting 4,7-diphenyl-1,10-phenanthroline (Bphen) exhibit a high external quantum efficiency (EQE) of up to 8.4% and a negligible colour change (the colour coordinate of (0.39, 0.41) at 1000 cd m -2 ) with increasing brightness, whereas the device using a hole-transporting mCP spacer shows a relatively low EQE of 6.2% and a large shift of emitting colour with increasing brightness. Device performance is further characterized based on the charge transport behaviour of the spacers inserted between the two emitters.

  10. Factors affecting the efficiency of aerosolized salbutamol delivery via a metered dose inhaler and equine spacer device.

    Science.gov (United States)

    Pirie, R S; McGorum, B C; Owen, C; Carr, O; Oakley, H; McLachlan, G

    2017-06-01

    Despite frequent use of metered dose inhalers (MDIs) and spacers in equine practice, limited information exists on the efficiency of aerosol delivery using such devices. We determined the particle size distribution within an MDI-generated salbutamol aerosol delivered via an equine spacer using 'best practice' delivery technique and assessed the effect of variations in MDI use technique (shaking prior to each actuation, rapid repetitive actuations, and MDI angulation) on aerosol delivery efficiency. Under optimal conditions, only 53(±18) μg salbutamol per 100 μg actuation was delivered beyond the spacer. Although this aerosol had a high [89.6% (±2.4)] fine particle (aerodynamic diameter [2.52 (±0.29) μm], and particle size variability [geometric SD - 1.66 (±0.16) μm], within all particle size fractions, there was a high coefficient of variance (31-79%) of the percentage salbutamol delivered between experimental runs, thus impeding any effort to predict drug delivery to the patient during equine inhalation therapy. Despite observable trends and with the exception of minor statistically significant changes in the least abundant particle sizes, none of the deviations from a 'best practice' delivery technique significantly altered the relative salbutamol delivery beyond the spacer, a finding which has potential relevance with regard to maintaining user compliance. © 2016 John Wiley & Sons Ltd.

  11. A Novel Murine Model of Established Staphylococcal Bone Infection in the Presence of a Fracture Fixation Plate to Study Therapies Utilizing Antibiotic-laden Spacers after Revision Surgery

    Science.gov (United States)

    Inzana, Jason A.; Schwarz, Edward M.; Kates, Stephen L.; Awad, Hani A.

    2014-01-01

    Mice are the small animal model of choice in biomedical research due to the low cost and availability of genetically engineered lines. However, the devices utilized in current mouse models of implant-associated bone infection have been limited to intramedullary or trans-cortical pins, which are not amenable to treatments involving extensive debridement of a full-thickness bone loss and placement of a segmental antibiotic spacer. To overcome these limitations, we developed a clinically faithful model that utilizes a locking fracture fixation plate to enable debridement of an infected segmental bone defect (full-thickness osteotomy) during a revision surgery, and investigated the therapeutic effects of placing an antibiotic-laden spacer in the segmental bone defect. To first determine the ideal time point for revision following infection, a 0.7 mm osteotomy in the femoral mid-shaft was stabilized with a radiolucent PEEK fixation plate. The defect was inoculated with bioluminescent Staphylococcus aureus, and the infection was monitored over 14 days by bioluminescent imaging (BLI). Osteolysis and reactive bone formation were assessed by X-ray and micro-computed tomography (micro-CT). The active bacterial infection peaked by 5 days post-inoculation, however the stability of the implant fixation became compromised by 10–14 days post-inoculation due to osteolysis around the screws. Thus, day 7 was defined as the ideal time point to perform the revision surgery. During the revision surgery, the infected tissue was debrided and the osteotomy was widened to 3 mm to place a poly-methyl methacrylate spacer, with or without vancomycin. Half of the groups also received systemic vancomycin for the remaining 21 days of the study. The viable bacteria remaining at the end of the study were measured using colony forming unit assays. Volumetric bone changes (osteolysis and reactive bone formation) were directly measured using micro-CT image analysis. Mice that were treated with

  12. Sub-15 nm nano-pattern generation by spacer width control for high density precisely positioned self-assembled device nanomanufacturing

    KAUST Repository

    Rojas, Jhonathan Prieto; Hussain, Muhammad Mustafa

    2012-01-01

    We present a conventional micro-fabrication based thin film vertical sidewall (spacer) width controlled nano-gap fabrication process to create arrays of nanopatterns for high density precisely positioned self-assembled nanoelectronics device integration. We have used conventional optical lithography to create base structures and then silicon nitride (Si 3N4) based spacer formation via reactive ion etching. Control of Si3N4 thickness provides accurate control of vertical sidewall (spacer) besides the base structures. Nano-gaps are fabricated between two adjacent spacers whereas the width of the gap depends on the gap between two adjacent base structures minus width of adjacent spacers. We demonstrate the process using a 32 nm node complementary metal oxide semiconductor (CMOS) platform to show its compatibility for very large scale heterogeneous integration of top-down and bottom-up fabrication as well as conventional and selfassembled nanodevices. This process opens up clear opportunity to overcome the decade long challenge of high density integration of self-assembled devices with precise position control. © 2012 IEEE.

  13. Sub-15 nm nano-pattern generation by spacer width control for high density precisely positioned self-assembled device nanomanufacturing

    KAUST Repository

    Rojas, Jhonathan Prieto

    2012-08-01

    We present a conventional micro-fabrication based thin film vertical sidewall (spacer) width controlled nano-gap fabrication process to create arrays of nanopatterns for high density precisely positioned self-assembled nanoelectronics device integration. We have used conventional optical lithography to create base structures and then silicon nitride (Si 3N4) based spacer formation via reactive ion etching. Control of Si3N4 thickness provides accurate control of vertical sidewall (spacer) besides the base structures. Nano-gaps are fabricated between two adjacent spacers whereas the width of the gap depends on the gap between two adjacent base structures minus width of adjacent spacers. We demonstrate the process using a 32 nm node complementary metal oxide semiconductor (CMOS) platform to show its compatibility for very large scale heterogeneous integration of top-down and bottom-up fabrication as well as conventional and selfassembled nanodevices. This process opens up clear opportunity to overcome the decade long challenge of high density integration of self-assembled devices with precise position control. © 2012 IEEE.

  14. Multi-Device Knob Utility for LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Zelazny, Michael; Chevtsov, Sergei; Chu, Chungming Paul; Fairley, Diane; Krejcik, Patrick; Rogind, Deborah; Smith, Howard; White, Greg; Yocky, Gerald; /SLAC

    2009-12-09

    At the SLAC National Accelerator Laboratory (SLAC) the Controls Department (CD) has developed a new Multi-Device Knob Utility (MKB) based on the Experimental Physics and Industrial Control System (EPICS) toolkit for controlling one or more Process Variables (PVs) in unison, or simultaneously, from a physical knob located in the control room, or from various software tools such as the EPICS Extensible Display Manager (EDM) or a Swing slider in Java. A group of devices are hooked up to a knob, and then the value written to the devices is a simple function of the value of the knob. This is used, most commonly, to create a bump in the electron beam for the Linac Coherent Light Source (LCLS). Control system variables typically controlled are magnetic fields, phases, and timing offsets. This paper describes the technologies used to implement this utility.

  15. Framework for utilizing computational devices within simulation

    Directory of Open Access Journals (Sweden)

    Miroslav Mintál

    2013-12-01

    Full Text Available Nowadays there exist several frameworks to utilize a computation power of graphics cards and other computational devices such as FPGA, ARM and multi-core processors. The best known are either low-level and need a lot of controlling code or are bounded only to special graphic cards. Furthermore there exist more specialized frameworks, mainly aimed to the mathematic field. Described framework is adjusted to use in a multi-agent simulations. Here it provides an option to accelerate computations when preparing simulation and mainly to accelerate a computation of simulation itself.

  16. Fuel spacer

    International Nuclear Information System (INIS)

    Nishida, Koji; Yokomizo, Osamu; Kanazawa, Toru; Kashiwai, Shin-ichi; Orii, Akihito.

    1992-01-01

    The present invention concerns a fuel spacer for a fuel assembly of a BWR type reactor and a PTR type reactor. Springs each having a vane are disposed on the side surface of a circular cell which supports a fuel rods. A vortex streams having a vertical component are formed by the vanes in the flowing direction of a flowing channel between adjacent cylindrical cells. Liquid droplets carried by streams are deposited on liquid membrane streams flowing along the fuel rod at the downstream of the spacer by the vortex streams. In view of the above, the liquid droplets can be deposited to the fuel rod without increasing the amount of metal of the spacer. Accordingly, the thermal margin of the fuel assembly can be improved without losing neutron economy. (I.N.)

  17. Utilization technique on variable speed device

    International Nuclear Information System (INIS)

    1989-12-01

    This reports of workshop on power technology describes using technique on variable speed device, which deals with alternating current situation and prospect of current variable speed device, technical trend and prospect of electronics, reduce expenses by variable speed device, control technique, measurement technology, high voltage variable speed device, recent trend of inverter technology, low voltage and high voltage variable speed device control device, operating variable speed device in cooling fan, FDF application and defect case of variable speed device, cooling pump application of water variable transformer, inverter application and energy effect of ventilation equipment, application of variable speed device and analysis of the result of operation and study for application of variable speed technology.

  18. An afterloading brachytherapy device utilizing thermoplastic material

    International Nuclear Information System (INIS)

    Kim, T.H.; Gerbi, J.B.; Deibel, F.C.; Khan, F.M.; Priest, J.R.

    1989-01-01

    An afterloading brachytherapy device for treatment of residual cancer in an enucleated orbit with two cesium-137 sources was designed using a thermoplastic material, Aquaplast. The device consists of a face-mask support held in place with elastic bands around the head and an acrylic afterloading applicator. The device is very easy to make, holds the sources firmly in place, allows full mobility of the patient, and gives excellent dose distribution to the target area. It was easily tolerated by a 7-year-old child during the 50 h of treatment. (author). 3 refs.; 4 figs

  19. WORM memory devices based on conformation change of a PVK derivative with a rigid spacer in side chain

    International Nuclear Information System (INIS)

    Liu Yuanhua; Li Najun; Xia Xuewei; Xu Qingfeng; Ge Jianfeng; Lu Jianmei

    2010-01-01

    A nonvolatile write-once-read-many-times (WORM) memory device based on poly((4-vinylbenzyl)-9H-carbazole) (PVCz) was fabricated by a simple and conventional process. The as-fabricated device was found to be at its OFF state and could be programmed irreversibly to the ON state with a low transition voltage of -1.7 V. The device exhibits a high ON/OFF current ratio of up to 10 6 , high stability in retention time up to 8 h and number of read cycles up to 10 8 under a read voltage of -1.0 V in both ON and OFF states. The results of X-ray diffraction (XRD) and fluorescence emission spectra in different states of PVCz indicate that the electrical bistable phenomenon is caused by the voltage-induced conformation change of the pendant carbazole groups. With high performance, low power consumption and low production cost, the device fabricated with PVCz has a potential application for nonvolatile memory.

  20. Seismic Device UVS 1504, possibilities of its Utilization

    Directory of Open Access Journals (Sweden)

    Leššo Igor

    1996-09-01

    Full Text Available Department of Mining and Geotechnics for many years deals with questions of the technical seismicity. In the paper are given possibilities of utilizing the UVS 1504 device and results obtained from the measurement of seismic effects of blasting as well as others sources of bursts. The measurements showed that this device enables to measure parameters and to evaluate measured data quickly, reliably, and with a very high precision. The device enables evaluating individual time degrees of blasts, determining the law of attenuation of the seismic waves, and precise determination of the maximum charge permissible for futher advance of the blasting in given conditions.

  1. Multi-Device Knob Utility for LCLS at SLAC

    International Nuclear Information System (INIS)

    Zelazny, Michael

    2009-01-01

    At the SLAC National Accelerator Laboratory (SLAC) the Controls Department (CD) has developed a new Multi-Device Knob Utility (MKB) based on the Experimental Physics and Industrial Control System (EPICS) toolkit for controlling one or more Process Variables (PVs) in unison, or simultaneously, from a physical knob located in the control room, or from various software tools such as the EPICS Extensible Display Manager (EDM) or a Swing slider in Java. A group of devices are hooked up to a knob, and then the value written to the devices is a simple function of the value of the knob. This is used, most commonly, to create a bump in the electron beam for the Linac Coherent Light Source (LCLS). Control system variables typically controlled are magnetic fields, phases, and timing offsets. This paper describes the technologies used to implement this utility.

  2. A high-performance channel engineered charge-plasma-based MOSFET with high-κ spacer

    Science.gov (United States)

    Shan, Chan; Wang, Ying; Luo, Xin; Bao, Meng-tian; Yu, Cheng-hao; Cao, Fei

    2017-12-01

    In this paper, the performance of graded channel double-gate MOSFET (GC-DGFET) that utilizes the charge-plasma concept and a high-κ spacer is investigated through 2-D device simulations. The results demonstrate that GC-DGFET with high-κ spacer can effectively improve the ON-state driving current (ION) and reduce the OFF-leakage current (IOFF). We find that reduction of the initial energy barrier between the source and channel is the origin of this ION enhancement. The reason for the IOFF reduction is identified to be the extension of the effective channel length owing to the fringing field via high-κ spacers. Consequently, these devices offer enhanced performance by reducing the total gate-to-gate capacitance (Cgg) and decreasing the intrinsic delay (τ).

  3. Spacer st4ructure

    International Nuclear Information System (INIS)

    Masetti, W.R.

    1978-01-01

    A spacer structure is described for maintaining a spaced relation between a plurality of generally parallel fuel rods within a housing in a nuclear reactor. The spacer structure is comprised of a grid pattern of ribs slotted to interlock with each other. The slots are arranged in such a way that when the ribs are welded to each other, the weld shrinkage is distributed uniformly in all directions to reduce or eliminate the amount of rework necessary in manufacturing the spacer structure

  4. Fouling resistant membrane spacers

    KAUST Repository

    Ghaffour, Noreddine

    2017-10-12

    Disclosed herein are spacers having baffle designs and perforations for efficiently and effectively separating one or more membrane layers a membrane filtration system. The spacer (504) includes a body (524) formed at least in part by baffles (520) that are interconnected, and the baffles define boundaries of openings or apertures (525) through a thickness direction of the body of the spacer. Alternatively or additionally, passages or perforations (526A, 526B) may be present in the spacer layer or baffles for fluid flow there through, with the passages and baffles having a numerous different shapes and sizes.

  5. Mixing vane grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Galbraith, K.P.

    1978-01-01

    An improved mixing vane grid spacer having enhanced flow mixing capability by virtue of mixing vanes being positioned at welded intersecting joints of the spacer wherein each mixing vane has an opening or window formed therein substantially directly over the welded joint to provide improved flow mixing capability is described. Some of the vanes are slotted, depending on their particular location in the spacers. The intersecting joints are welded by initially providing consumable tabs at and within each window, which are consumed during the welding of the spacer joints

  6. Highly Efficient White Organic Light-Emitting Diodes with Ultrathin Emissive Layers and a Spacer-Free Structure

    Science.gov (United States)

    Wu, Shengfan; Li, Sihua; Sun, Qi; Huang, Chenchao; Fung, Man-Keung

    2016-05-01

    Ultrathin emissive layers (UEMLs) of phosphorescent materials with a layer thickness of less than 0.3 nm were introduced for high-efficiency organic light-emitting diodes (OLEDs). All the UEMLs for white OLEDs can be prepared without the use of interlayers or spacers. Compared with devices fabricated with interlayers inserted in-between the UEMLs, our spacer-free structure not only significantly improves device efficiency, but also simplifies the fabrication process, thus it has a great potential in lowering the cost of OLED panels. In addition, its spacer-free structure decreases the number of interfaces which often introduce unnecessary energy barriers in these devices. In the present work, UEMLs of red, green and blue-emitting phosphorescent materials and yellow and blue phosphorescent emitters are utilized for the demonstration of spacer-free white OLEDs. Upon optimization of the device structure, we demonstrated spacer-free and simple-structured white-emitting OLEDs with a good device performance. The current and power efficiencies of our white-emitting devices are as high as 56.0 cd/A and 55.5 lm/W, respectively. These efficiencies are the highest ever reported for OLEDs fabricated with the UEML approach.

  7. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    International Nuclear Information System (INIS)

    Elshurafa, Amro M; El-Masry, Ezz I

    2010-01-01

    This paper, the first in a series of two, presents a paradigm shift in the design of MEMS parallel plate PolyMUMPS variable capacitance devices by proposing two structures that utilize the substrate and are able to provide predetermined, customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices where the tuning range is fixed and cannot be varied. Theoretical analysis is carried out and verified with measurements of fabricated devices. The first proposed device possessed initially a tuning range of 4.4. Two variations of the structure having tuning ranges of 3 and 3.4, all at 1 GHz, were also successfully developed and tested. The second proposed variable capacitance device behaved as a switch.

  8. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    KAUST Repository

    Elshurafa, Amro M.

    2010-03-22

    This paper, the first in a series of two, presents a paradigm shift in the design of MEMS parallel plate PolyMUMPS variable capacitance devices by proposing two structures that utilize the substrate and are able to provide predetermined, customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices where the tuning range is fixed and cannot be varied. Theoretical analysis is carried out and verified with measurements of fabricated devices. The first proposed device possessed initially a tuning range of 4.4. Two variations of the structure having tuning ranges of 3 and 3.4, all at 1 GHz, were also successfully developed and tested. The second proposed variable capacitance device behaved as a switch. © 2010 IOP Publishing Ltd.

  9. Structural Stator Spacers

    DEFF Research Database (Denmark)

    Rasmussen, Peter Omand; Andreasen, Jens H.; Pijanowski, J. M.

    2001-01-01

    This paper presents a powerful new design aspect to reduce acoustic noise and vibration of electro-magnetic origin for electrical machines, by introducing improved slot wedges referred to as "Structural Stator Spacers". These spacers, by using a very stiff dielectric and non magnetic material...

  10. Utilization of Remote Experimentation in Mobile Devices for Education

    Directory of Open Access Journals (Sweden)

    Willian Rochadel

    2012-07-01

    Full Text Available In this paper the authors intend to demonstrate the utilization of remote experimentation (RE using mobile computational devices in the Science areas of the elementary school, with the purpose to develop practices that will help in the assimilation process of the subjects taught in classroom seeking to interlink them with the daily students’ activities. Allying mobility with RE we intend to minimize the space-temporal barrier giving more availability and speed in the information access. The implemented architecture utilizes technologies and freely distributed softwares with open code resources besides remote experiments developed in the Laboratory of Remote Experimentation (RExLab of Federal University of Santa Catarina (UFSC, in Brazil, through the physical computation platform of the “open hardware” of construction of our own. The utilization of open code computational tools and the integration of hardware to the 3D virtual worlds, accessible through mobile devices, give to the project an innovative face with a high potential for reproducibility and reusability.

  11. Vaginoscopy in Ewes Utilizing a Laparoscopic Surgical Port Device

    Directory of Open Access Journals (Sweden)

    Jeremiah Easley

    2017-01-01

    Full Text Available Vaginoscopy allows for diagnostic evaluation and treatment of the vaginal vault. A laparoscopic surgical port device and rigid telescope were utilized for serial vaginoscopy in 8 healthy anesthetized ewes. Vaginoscopy examinations were performed in each ewe at days 1, 14, and 28. This technique was well-tolerated and facilitated carbon dioxide vaginal inflation, complete vaginal examination, identification of the cervix, and targeted biopsy collection. No complications were encountered during or following the vaginoscopy procedures. The laparoscopic port device was well-suited to the ewe vulvar size. This technique could be applied to clinical evaluation in ewes for the purposes of examination, biopsy, culture, foreign body removal, and minor surgical procedures.

  12. Study of special spacer with damping device for suppressing wake galloping in tandem cables of cable-stayed bridges and its application to full scale bridge; Nendanseitai wo riyoshita heiretsu cable yo gensui kinotsuki spacer to sono jikkyo cable eno tekiyo ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M.; Setouchi, H.; Yoshioka, A. [Kawada Industries Inc., Tokyo (Japan); Shimoda, I.; Kawahara, S. [Oiles Corp., Tokyo (Japan)

    1996-12-20

    Cable vibration called wake galloping occurs in a cable-stayed bridge, in which cables are arranged tandem, and suppression of the vibration is an extremely important discussion item. This paper describes a complex eigen value analysis performed on tandem cables having lengths of 200 m and 100 m. The analysis revealed that damping characteristics added by a spacer system with a damping device (a type to install a visco-elastic body at about middle of the tandem cables via a jig) depend largely on torsional rigidity of the cables; and the characteristics may vary with difference in intervals between cable centers and that in cable diameters. A visco-elastic damping material of an asphalt system and a spacer with a damping device used as a spring material were fabricated and applied to a full scale bridge to identify quantitatively the damping addition characteristics of this system. Furthermore, the results of tests on the full scale bridge were compared with the result of the complex eigen value analysis, from which findings useful for actual works were obtained. 18 refs., 17 figs., 6 tabs.

  13. Some considerations on special spacers with damping device for suppressing wake galloping in tandem cables of cable-stayed bridges; Heiretsu cable yo gensui kino tsuki supesa no gensui fuka tokusei ni kansuru 2,3 no kosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M. [Kinki Univ., Higashi-Osaka, Osaka (Japan). Faculty of Science and Technology] Setouchi, H. [Kawada Industries Inc., Osaka (Japan)

    1998-03-20

    Cable vibration called wake galloping appears on cable-stayed bridges with parallel arranged cables and its suppression is an important problem. Various methods have been proposed for spacers with damping device for suppressing wake galloping in tandem cables of cable-stayed bridges. But, comparison of damping performances of various methods have not been discussed sufficiently. This paper deals with a type in which dampers are equipped on the midway of the tandem cables through the spacer jig and a type in which dampers are equipped on each surface of the tandem cables to generate shear deformation between them and circular spacer jig moiety and complex eigenvalue analyses are carried out on the two types with changing center spacing and diameters of the cables. The results clarify the relation between the structural damping characteristics and the cable spacing and the effect of torsional rigidity of the cables and also clarify of damping characteristics of the two types. 16 refs., 14 figs., 4 tabs.

  14. Antibiotic impregnated total femur spacers: a technical tip

    Directory of Open Access Journals (Sweden)

    Colin D. Canham, MD

    2018-03-01

    Full Text Available Simultaneous prosthetic joint infection of ipsilateral hip and knee arthroplasties is often accompanied by significant bone loss and presents a challenging reconstructive problem. Two-stage reconstruction is favored and requires the placement of a total femur spacer, which is not a commercially available device. We describe a surgical technique, reporting on 2 cases in which a customized total femur antibiotic impregnated spacer was created by combining an articulating knee spacer and an articulating hip spacer with a reinforced cement dowel construct connecting the 2 spacers. Custom total femoral spacers are useful in the management of infected femoral megaprostheses and cases with ipsilateral injected hip and knee arthroplasties and severe femoral bone loss. Keywords: total femur spacer, revision arthroplasty, total hip arthroplasty, total knee arthroplasty, prosthetic joint infection

  15. Membrane with integrated spacer

    NARCIS (Netherlands)

    Balster, J.H.; Stamatialis, Dimitrios; Wessling, Matthias

    2010-01-01

    Many membrane processes are severely influenced by concentration polarisation. Turbulence promoting spacers placed in between the membranes can reduce the diffusional resistance of concentration polarisation by inducing additional mixing. Electrodialysis (ED) used for desalination suffers from

  16. Processes for multi-layer devices utilizing layer transfer

    Science.gov (United States)

    Nielson, Gregory N; Sanchez, Carlos Anthony; Tauke-Pedretti, Anna; Kim, Bongsang; Cederberg, Jeffrey; Okandan, Murat; Cruz-Campa, Jose Luis; Resnick, Paul J

    2015-02-03

    A method includes forming a release layer over a donor substrate. A plurality of devices made of a first semiconductor material are formed over the release layer. A first dielectric layer is formed over the plurality of devices such that all exposed surfaces of the plurality of devices are covered by the first dielectric layer. The plurality of devices are chemically attached to a receiving device made of a second semiconductor material different than the first semiconductor material, the receiving device having a receiving substrate attached to a surface of the receiving device opposite the plurality of devices. The release layer is etched to release the donor substrate from the plurality of devices. A second dielectric layer is applied over the plurality of devices and the receiving device to mechanically attach the plurality of devices to the receiving device.

  17. MEMS variable capacitance devices utilizing the substrate: II. Zipping varactors

    KAUST Repository

    Elshurafa, Amro M.

    2010-03-22

    This paper, the second and last in this series, introduces PolyMUMPS zipping varactors that exploit the substrate and provide a high tuning range and a high quality factor. Building on the important findings of part I of this paper, the substrate was utilized effectively once again in the design and fabrication of zipping varactors to attain devices with very good performance. Two zipping varactors are proposed, analysed theoretically, simulated, fabricated and tested successfully. The tuning range, quality factor and actuation voltage of those varactors are 4.5, 16.4, 55 V and 4.2, 17, 55 V respectively. Finally, and based on one of the proposed zipping varactors, a very large capacitance value varactor array, with a tuning range of 5.3, was designed and tested. To the best of our knowledge, these zipping varactors exhibit the best reported characteristics in PolyMUMPS to date within their category in terms of tuning range, quality factor, required actuation voltage and total area consumed. © 2010 IOP Publishing Ltd.

  18. Side insertable spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Ewing, R.H.

    1992-01-01

    This patent describes a spacer for restraining the fuel rods of a nuclear fuel assembly, the assembly being formed of a plurality of parallel, elongated fuel rods so arranged that the assembly is bounded by a polygon having an even number of sides, the rods being so arranged as to lie in a plurality of sets of parallel rows, the rows of each set being perpendicular to one of the sides of the polygon. It comprises a number of spacer combs equal to at least half the number of the sides of the polygon, the spacer combs being superposed on each other, each of the spacer combs comprising: a single base strip having a length equal to that of one of the sides of the polygon and grid strips equal in number to the spaces between rows in one of the sets, and at least a majority of the grid strips being of a length sufficient to extend substantially the full length of the rows; the grid strips being provided with spring members positioned to engage each of the rods; the grid strips being provided with spring members positioned to engage each of the rods; the grid strips being secured to and extending at right angles to the base strip; the grid strips of different combs being positioned at angles to each other, so as to occupy the spaces between rows in different sets

  19. Nuclear reactor fuel assembly spacer grids

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1977-01-01

    Designs of nuclear reactor fuel assembly spacer grids for supporting and spacing fuel elements are described which do not utilize resilient grid plate protrusions in the peripheral band but retain the advantages inherent in the combination resilient and rigid protrusion cells. (U.K.)

  20. Secondary structure analyses of the nuclear rRNA internal transcribed spacers and assessment of its phylogenetic utility across the Brassicaceae (mustards.

    Directory of Open Access Journals (Sweden)

    Patrick P Edger

    Full Text Available The internal transcribed spacers of the nuclear ribosomal RNA gene cluster, termed ITS1 and ITS2, are the most frequently used nuclear markers for phylogenetic analyses across many eukaryotic groups including most plant families. The reasons for the popularity of these markers include: 1. Ease of amplification due to high copy number of the gene clusters, 2. Available cost-effective methods and highly conserved primers, 3. Rapidly evolving markers (i.e. variable between closely related species, and 4. The assumption (and/or treatment that these sequences are non-functional, neutrally evolving phylogenetic markers. Here, our analyses of ITS1 and ITS2 for 50 species suggest that both sequences are instead under selective constraints to preserve proper secondary structure, likely to maintain complete self-splicing functions, and thus are not neutrally-evolving phylogenetic markers. Our results indicate the majority of sequence sites are co-evolving with other positions to form proper secondary structure, which has implications for phylogenetic inference. We also found that the lowest energy state and total number of possible alternate secondary structures are highly significantly different between ITS regions and random sequences with an identical overall length and Guanine-Cytosine (GC content. Lastly, we review recent evidence highlighting some additional problematic issues with using these regions as the sole markers for phylogenetic studies, and thus strongly recommend additional markers and cost-effective approaches for future studies to estimate phylogenetic relationships.

  1. Fuel assembly spacer

    International Nuclear Information System (INIS)

    Shirakawa, Ken-etsu.

    1988-01-01

    Purpose: To reduce the pressure loss of coolants by fuel assembly spacers. Constitution: Spacers for supporting a fuel assembly are attached by means of a plurality of wires to an outer frame. The outer frame is made of shape memory alloy such that the wires are caused to slacken at normal temperature and the slacking of the wires is eliminated in excess of the transition temperature. Since the wires slacken at the normal temperature, fuel rods can be inserted easily. After the insertion of the fuel rods, when the entire portion or the outer frame is heated by water or gas at a predetermined temperature, the outer frame resumes its previously memorized shape to tighten the wires and, accordingly, the fuel rods can be supported firmly. In this way, since the fuel rods are inserted in the slacken state of the wires and, after the assembling, the outer frame resumes its memorized shape, the assembling work can be conducted efficiently. (Kamimura, M.)

  2. Utilizing Mobile Devices to Enrich the Learning Style of Students

    Science.gov (United States)

    McGovern, Enda F.; Luna-Nevarez, Cuauhtemoc; Baruca, Arne

    2017-01-01

    As digital technologies evolve in education, business faculty have increased access to an extensive range of mobile devices and online applications to help them inspire students' passion for learning. Adopting new digital approaches to teaching can also enhance the learning style of students who are immersed in the use of digital devices. How can…

  3. Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

    Science.gov (United States)

    Scardelletti, Maximilian C.; Goldman, Rachel

    2004-01-01

    Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria

  4. 77 FR 30368 - Defense Federal Acquisition Regulation Supplement; Utilization of Domestic Photovoltaic Devices...

    Science.gov (United States)

    2012-05-22

    ... arrangement, the Government would take title to the devices during contract performance or at the conclusion... rule will promote utilization of domestic photovoltaic devices, even when the Government does not take... Devices (DFARS Case 2011-D046) AGENCY: Defense Acquisition Regulations System, Department of Defense (DoD...

  5. CFD application to advanced design for high efficiency spacer grid

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Kazuo, E-mail: kazuo3_ikeda@ndc.mhi.co.jp

    2014-11-15

    Highlights: • A new LDV was developed to investigate the local velocity in a rod bundle and inside a spacer grid. • The design information that utilizes for high efficiency spacer grid has been obtained. • CFD methodology that predicts flow field in a PWR fuel has been developed. • The high efficiency spacer grid was designed using the CFD methodology. - Abstract: Pressurized water reactor (PWR) fuels have been developed to meet the needs of the market. A spacer grid is a key component to improve thermal hydraulic performance of a PWR fuel assembly. Mixing structures (vanes) of a spacer grid promote coolant mixing and enhance heat removal from fuel rods. A larger mixing vane would improve mixing effect, which would increase the departure from nucleate boiling (DNB) benefit for fuel. However, the increased pressure loss at large mixing vanes would reduce the coolant flow at the mixed fuel core, which would reduce the DNB margin. The solution is to develop a spacer grid whose pressure loss is equal to or less than the current spacer grid and that has higher critical heat flux (CHF) performance. For this reason, a requirement of design tool for predicting the pressure loss and CHF performance of spacer grids has been increased. The author and co-workers have been worked for development of high efficiency spacer grid using Computational Fluid Dynamics (CFD) for nearly 20 years. A new laser Doppler velocimetry (LDV), which is miniaturized with fiber optics embedded in a fuel cladding, was developed to investigate the local velocity profile in a rod bundle and inside a spacer grid. The rod-embedded fiber LDV (rod LDV) can be inserted in an arbitrary grid cell instead of a fuel rod, and has the advantage of not disturbing the flow field since it is the same shape as a fuel rod. The probe volume of the rod LDV is small enough to measure spatial velocity profile in a rod gap and inside a spacer grid. According to benchmark experiments such as flow velocity

  6. CFD application to advanced design for high efficiency spacer grid

    International Nuclear Information System (INIS)

    Ikeda, Kazuo

    2014-01-01

    Highlights: • A new LDV was developed to investigate the local velocity in a rod bundle and inside a spacer grid. • The design information that utilizes for high efficiency spacer grid has been obtained. • CFD methodology that predicts flow field in a PWR fuel has been developed. • The high efficiency spacer grid was designed using the CFD methodology. - Abstract: Pressurized water reactor (PWR) fuels have been developed to meet the needs of the market. A spacer grid is a key component to improve thermal hydraulic performance of a PWR fuel assembly. Mixing structures (vanes) of a spacer grid promote coolant mixing and enhance heat removal from fuel rods. A larger mixing vane would improve mixing effect, which would increase the departure from nucleate boiling (DNB) benefit for fuel. However, the increased pressure loss at large mixing vanes would reduce the coolant flow at the mixed fuel core, which would reduce the DNB margin. The solution is to develop a spacer grid whose pressure loss is equal to or less than the current spacer grid and that has higher critical heat flux (CHF) performance. For this reason, a requirement of design tool for predicting the pressure loss and CHF performance of spacer grids has been increased. The author and co-workers have been worked for development of high efficiency spacer grid using Computational Fluid Dynamics (CFD) for nearly 20 years. A new laser Doppler velocimetry (LDV), which is miniaturized with fiber optics embedded in a fuel cladding, was developed to investigate the local velocity profile in a rod bundle and inside a spacer grid. The rod-embedded fiber LDV (rod LDV) can be inserted in an arbitrary grid cell instead of a fuel rod, and has the advantage of not disturbing the flow field since it is the same shape as a fuel rod. The probe volume of the rod LDV is small enough to measure spatial velocity profile in a rod gap and inside a spacer grid. According to benchmark experiments such as flow velocity

  7. Awareness and utilization of protective eye device among welders in ...

    African Journals Online (AJOL)

    Ramakantb

    was a high level of awareness of protective eye devices among the welders (367, 90.6%), being higher among arc welders compared ... each respondent in the field. The welders' ... Thermal retinal damage can also occur from near infrared ...

  8. Factors affecting the utilization of safety devices by commercial ...

    African Journals Online (AJOL)

    Background: Motorcycle crashes are common causes of morbidity and mortality for both riders and passengers. To prevent and reduce the severity of injuries sustained through road traffic accidents (RTA) many countries enforce the use of safety devices while riding. Certain factors including non-enforcement of the existing ...

  9. Utilizing an eye tracker device for operator support

    NARCIS (Netherlands)

    Greef, T.E. de; Lafeber, H.

    2007-01-01

    At present a number of studies have attempted to embed eye-tracking devices into closed-loop systems to augment the cognitive state of the human operator. It has been demonstrated that the pupil diameter and blinking frequency serve as such indicators. Although these two factors serve cognitive

  10. Utilization of ocular safety devices among Sawmill workers in Nigeria

    African Journals Online (AJOL)

    Objective: The study was carried out to assess the use of eye safety devices in sawmill workers in Nigeria. Methods: A cross-sectional study of sawmill workers was carried out using pretested questionnaires. Ocular examination was done on site with a pen torch, portable hand-held slit lamp bio-microscope and direct ...

  11. Consumer sleep tracking devices: a review of mechanisms, validity and utility.

    Science.gov (United States)

    Kolla, Bhanu Prakash; Mansukhani, Subir; Mansukhani, Meghna P

    2016-05-01

    Consumer sleep tracking devices such as fitness trackers and smartphone apps have become increasingly popular. These devices claim to measure the sleep duration of their users and in some cases purport to measure sleep quality and awaken users from light sleep, potentially improving overall sleep. Most of these devices appear to utilize data generated from in-built accelerometers to determine sleep parameters but the exact mechanisms and algorithms are proprietary. The growing literature comparing these devices against polysomnography/actigraphy shows that they tend to underestimate sleep disruptions and overestimate total sleep times and sleep efficiency in normal subjects. In this review, we evaluate the current literature comparing the accuracy of consumer sleep tracking devices against more conventional methods used to measure sleep duration and quality. We discuss the current technology that these devices utilize as well as summarize the value of these devices in clinical evaluations and their potential limitations.

  12. Spacer grid corner gusset

    International Nuclear Information System (INIS)

    Larson, J.G.

    1984-01-01

    There is provided a spacer grid for a bundle of longitudinally extending rods in spaced generally parallel relationship comprising spacing means for holding the rods in spaced generally parallel relationship; the spacing means includes at least one exterior grid strip circumscribing the bundle of rods along the periphery thereof; with at least one exterior grid strip having a first edge defining the boundary of the strip in one longitudinal direction and a second edge defining the boundary of the strip in the other longitudinal direction; with at least one exterior grid strip having at least one band formed therein parallel to the longitudinal direction; a plurality of corner gussets truncating each of a plurality of corners formed by at least one band and the first edge and the second edge

  13. BIPV-powered smart windows utilizing photovoltaic and electrochromic devices.

    Science.gov (United States)

    Ma, Rong-Hua; Chen, Yu-Chia

    2012-01-01

    A BIPV-powered smart window comprising a building-integrated photovoltaic (BIPV) panel and an all-solid-state electrochromic (EC) stack is proposed. In the proposed device, the output voltage of the BIPV panel varies in accordance with the intensity of the incident light and is modulated in such a way as to generate the EC stack voltage required to maintain the indoor illuminance within a specified range. Two different EC stacks are fabricated and characterized, namely one stack comprising ITO/WO(3)/Ta(2)O(5)/ITO and one stack comprising ITO/WO(3)/lithium-polymer electrolyte/ITO. It is shown that of the two stacks, the ITO/WO(3)/lithium-polymer electrolyte/ITO stack has a larger absorptance (i.e., approximately 99% at a driving voltage of 3.5 V). The experimental results show that the smart window incorporating an ITO/WO(3)/lithium-polymer electrolyte/ITO stack with an electrolyte thickness of 1.0 μm provides an indoor illuminance range of 750-1,500 Lux under typical summertime conditions in Taiwan.

  14. BIPV-Powered Smart Windows Utilizing Photovoltaic and Electrochromic Devices

    Directory of Open Access Journals (Sweden)

    Yu-Chia Chen

    2011-12-01

    Full Text Available A BIPV-powered smart window comprising a building-integrated photovoltaic (BIPV panel and an all-solid-state electrochromic (EC stack is proposed. In the proposed device, the output voltage of the BIPV panel varies in accordance with the intensity of the incident light and is modulated in such a way as to generate the EC stack voltage required to maintain the indoor illuminance within a specified range. Two different EC stacks are fabricated and characterized, namely one stack comprising ITO/WO3/Ta2O5/ITO and one stack comprising ITO/WO3/lithium-polymer electrolyte/ITO. It is shown that of the two stacks, the ITO/WO3/lithium-polymer electrolyte/ITO stack has a larger absorptance (i.e., approximately 99% at a driving voltage of 3.5 V. The experimental results show that the smart window incorporating an ITO/WO3/lithium-polymer electrolyte/ITO stack with an electrolyte thickness of 1.0 μm provides an indoor illuminance range of 750–1,500 Lux under typical summertime conditions in Taiwan.

  15. Elmo Bumpy Torus proof of principle, Phase II: Title 1 report. Volume VIII. Device utilities

    International Nuclear Information System (INIS)

    Erickson, D.T.

    1982-01-01

    This report describes the activities conducted during the Preliminary Design Period for the Device Utilities Systems. All GAI preliminary specifications, drawings, and reports (listed in Section 4.0) have been transmitted to ORNL for review and approval. Device Utility Systems Descriptions are also presented in Section 4.0. The GAI Device Enclosure Gamma Radiation Analysis is presented in Appendix B. Pending design criteria revisions are described in Section 6.0. A type B Change Notice Request (CNR) has been transmitted to GAI. The Type B CNR authorizes cost and schedule assessment for each revision identified. Formal Proposed Design Changes (PDC's) will be provided to ORNL when this data is available

  16. A capillary pumping device utilizing super-hydrophobic silicon grass

    International Nuclear Information System (INIS)

    Kung, Chun-Fei; Chang, Chien-Cheng; Chu, Chin-Chou

    2011-01-01

    In this study, we show that a compact silicon grass surface can be generated by utilizing the induced coupled plasma method with suitably chosen fabrication parameters. This super-hydrophobic structure suspends deionized water on top of the grass and keeps the contact angle at around 153°. The silicon grass is used to improve the driving efficiency of a capillary pumping micro-duct (without sidewalls), which is completely defined by a bottom hydrophilic stripe (adjacent to a Teflon substrate) and a fully top-covered hydrophobic Teflon surface which is coated on a glass substrate. The channel has a height of 3 µm and a width of 100 µm. In this work, the Teflon substrate is replaced with the silicon grass surface. When the fluid is flowing through the micro-duct on the stripe, the interface between the silicon grass and the hydrophilic stripe forms a stable air cushion barrier to the fluid, thus effectively reducing the frictional force. By changing only the interface with this replacement, we demonstrate that the average measured velocities of the new design show improvements of 21% and 17% in the driving efficiency over the original design for transporting deionized water and human blood, respectively. It is also shown that the measured data of the present design are closer to the values predicted by a theoretical analysis which relates the flow velocity to the contact angles, surface tension and fluid viscosity

  17. Modeling the effect of spacers and biofouling on forward osmosis performance

    KAUST Repository

    Mosqueira Santillán, María José

    2014-11-01

    Currently, the most utilized desalination technology is reverse osmosis (RO), where a membrane is used as a physical barrier to separate the salts from the seawater, using high hydraulic pressure as driving force. A major problem in RO systems is biofouling, caused by severe growth of bacterial biofilms. Both, the need of an external energy input, as well as biofouling, impose a high cost on RO operation. Forward osmosis (FO) is an alternative membrane process that uses an osmotic pressure difference as driving force. FO uses a concentrated draw solution to generate high osmotic pressure, which extracts water across a semi permeable membrane from a feed solution. One of the main advantages of FO is the limited amount of external energy required to extract water from the feed solution. The objective of this research is the assessment of the impact of spacers, separating the membrane sheets, and biofouling on the FO system performance. This type of studies allow the optimization of membrane devices and operational conditions. For this, a two dimensional numerical model for FO systems was developed using computational fluid dynamics (CFD). This model allowed the evaluation of the impact of (i) spacers and (ii) biofilm, and (iii) the combined impact of spacers and biofilm on the performance of FO systems. The results obtained showed that the presence of spacers improved the performance of FO systems. Cavity configuration spacer gave the higher water flux across the membrane in clean systems; whereas for biofouled systems, the submerged configuration showed a better performance. In absence of spacers, the thickness or amount of biofilm is inversely proportional with the water flux. Furthermore, membrane surface coverage of the biofilm is more important than the amount of biofilm in terms of the impact on the performance. The numerical model can be adapted with other parameters (e.g. membrane and spacer thickness, feed and draw solution, solution concentration, etc.) to

  18. Preliminary analysis of the effect of the grid spacers on the reflood heat transfer

    International Nuclear Information System (INIS)

    Sugimoto, Jun; Murao, Yoshio

    1982-02-01

    The results are described about the preliminary analysis of the effect of the grid spacers on the heat transfer during reflood phase of a PWR LOCA. Experiments at JAERI and other facilities showed substantial heat transfer enhancement near the grid spacers. The heat transfer enhancement decreases with the distance from the grid spacers in the downstream region of the grid spacers. Several mechanisms are discussed about the heat transfer enhancement near the grid spacers. A model of a coalescence of the water droplets downstream the spacers is proposed based on the review of the experimental data. The heat transfer correlation for the saturated film boiling is utilized to quantify the heat transfer augmentation by the grid spacers. (author)

  19. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    KAUST Repository

    Elshurafa, Amro M.; El-Masry, Ezz I.

    2010-01-01

    , customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices

  20. Pros and cons of symmetrical dual-k spacer technology in hybrid FinFETs

    Science.gov (United States)

    Pradhan, K. P.; Andrade, M. G. C.; Sahu, P. K.

    2016-12-01

    The symmetrical dual-k spacer technology in hybrid FinFETs has been widely explored for better electrostatic control of the fin-based devices in nanoscale region. Since, high-k tangible spacer materials are broadly became a matter of study due to their better immunity to the short channel effects (SCEs) in nano devices. However, the only cause that restricts the circuit designers from using high-k spacer is the unreasonable increasing fringing capacitances. This work quantitatively analyzed the benefits and drawbacks of considering two different dielectric spacer materials symmetrically in either sides of the channel for the hybrid device. From the demonstrated results, the inclusion of high-k spacer predicts an effective reduction in off-state leakage along with an improvement in drive current. However, these devices have paid the cost in terms of a high total gate-to-gate capacitance (Cgg) that consequently results poor cutoff frequency (fT) and delay.

  1. (ISSR) and internal transcribed spacer

    African Journals Online (AJOL)

    Cladistic relationships within the genus Cinnamomum (Lauraceae) in Taiwan based on analysis of leaf morphology and inter-simple sequence repeat (ISSR) and internal transcribed spacer (ITS) molecular markers.

  2. Heating device for thermal treatment of curred small diameter tubes and utilization of this device

    International Nuclear Information System (INIS)

    Jacquier, P.

    1988-01-01

    The heating device is made by a helical winding constituted from a resistance heating wire. The heating wire constituted the central core of a coaxial cable comprising an outer tubular metal envelope and an insulating layer interpolated between the central core and the outer envelope. The coaxial cable is wound in order to form a helical winding that forms the flexible element for introduction to the tube to be treated [fr

  3. Improving Smartphone Battery Life Utilizing Device-to-device Cooperative Relays Underlaying LTE Networks

    OpenAIRE

    Ta, Tuan; Baras, John S.; Zhu, Chenxi

    2014-01-01

    The utility of smartphones has been limited to a great extent by their short battery life. In this work, we propose a new approach to prolonging smartphone battery life. We introduce the notions of "valueless" and "valued battery", as being the available battery when the user does or does not have access to a power source, respectively. We propose a cooperative system where users with high battery level help carry the traffic of users with low battery level. Our scheme helps increase the amou...

  4. Exploring the Utility and Application of Framing Devices in College/University President Speeches

    Science.gov (United States)

    Young, Ira George

    2013-01-01

    The purpose of this study was to explore the utility and application of the framing devices identified by Fairhurst (1993) and Fairhurst and Sarr (1996) in the college/university setting as evidenced through college/university presidents' speeches. Fifty-seven college/university presidents' speeches were collected from institution…

  5. Elmo Bumpy Torus proof of principle, Phase II: Title 1 report. Volume VIII. Device utilities

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, D.T.

    1982-02-26

    This report describes the activities conducted during the Preliminary Design Period for the Device Utilities Systems. All GAI preliminary specifications, drawings, and reports (listed in Section 4.0) have been transmitted to ORNL for review and approval. Device Utility Systems Descriptions are also presented in Section 4.0. The GAI Device Enclosure Gamma Radiation Analysis is presented in Appendix B. Pending design criteria revisions are described in Section 6.0. A type B Change Notice Request (CNR) has been transmitted to GAI. The Type B CNR authorizes cost and schedule assessment for each revision identified. Formal Proposed Design Changes (PDC's) will be provided to ORNL when this data is available.

  6. Spacer grid for fuel elements

    International Nuclear Information System (INIS)

    Hensolt, T.; Huenner, M.; Rau, P.; Veca, A.

    1978-01-01

    The spacer grid for fuel elements of a gas-cooled fast breeder reactor (but also for PWRs and BWRs) consists of a lattice field with dodecagonal meshes. These meshes are formed by three each adjacent hexagons grouped arround a central axis. The pairs of legs extending into the dodecagon and being staggered by 120 0 are designed as knubs with inclined abutting surfaces for the fuel rods. By this means there is formed a three-point bearing for centering the fuel rods. The spacer grid mentioned above is rough-worked from a single disc- resp. plate-shaped body (unfinished piece). (DG) [de

  7. Spacer grid for fuel elements

    International Nuclear Information System (INIS)

    Hensolt, T.; Huenner, M.; Rau, P.; Veca, A.

    1980-01-01

    The spacer grid for fuel elements of a gas-cooled fast breeder reactor (but also for PWRs and BWRs) consists of a lattice field with dodecagonal meshes. These meshes are formed by three each adjacent hexagons grouped arround a central axis. The pairs of legs extending into the dodecagon and being staggered by 120 are designed as knubs with inclined abutting surfaces for the fuel rods. By this means there is formed a three-point bearing for centering the fuel rods. The spacer grid mentioned above is rough-worked from a single disc- resp. plate-shaped body (unfinished piece). (orig.)

  8. Active exercises utilizing a facilitating device in the treatment of lymphedema resulting from breast cancer therapy

    Directory of Open Access Journals (Sweden)

    de Fátima Guerreiro Godoy, Maria

    2010-01-01

    Full Text Available The aim of this study was to evaluate the reduction in volume of arm lymphedema secondary to breast cancer therapy utilizing an exercise facilitating device. Twenty-one women with arm lymphedema resulting from the surgical and radiotherapeutic treatment of breast cancer were randomly selected. Evaluation was made by water-displacement volumetry before and after each session. The patients were submitted to a series of active exercises using a facilitating device for four 12-minute sessions with intervals of 3 minutes between sessions in the sitting position with alignment of the spinal column. The lymphedematous arm was maintained under compression using a cotton-polyester sleeve. The active exercising device used was a mobile flexion bar fixed on a metal base at a height of 30 cm from the tabletop and at a distance of 10 cm from the patient’s body. The paired t-test was utilized for statistical analysis with an alpha error of 5% (p-value ≤0.05 being considered significant. The initial mean volume of the arms was 2,089.9 and the final volume was 2,023.0 mL with a mean loss of 66.9 mL (p-value <0.001. In conclusion, active exercises utilizing facilitating devices can contribute to a reduction in size of lymphedematous limbs.

  9. 3-D flow analyses for design of nuclear fuel spacer

    Energy Technology Data Exchange (ETDEWEB)

    Karouta, Z. [ABB Combustion Engineering, Windsor, CT (United States); GU, Chun-Yuan [ABB Corporate Research, Vaesteras (Sweden); Schoelin, B. [ABB Atom AB, Vaesteras (Sweden)

    1995-09-01

    The Computational Fluid Dynamics (CFD) code, CFDS-FLOW3D, was used to develop improved fuel designs for PWR cores. It was used primarily to understand the fluid dynamics of grid spacers, the mass transfer between subchannels caused by spacers and in the long term to develop two-phase models which enable prediction of critical heat flux in PWR fuel. A single subchannel of one grid span was modeled. In this model different spacer designs with mixing devices were analyzed. A special treatment of the boundary condition was developed making use of flow symmetry to model the mass transfer between different subchannels and minimize the size of the computational model. This reduced the computational model to a fraction of a subchannel using traditional periodic boundary conditions. The Navier-Stokes equation was solved for the liquid and the flow turbulence was modeled by k-{xi} turbulence model. The spacer and mixing device were treated as infinite thin surfaces in the model and a zero velocity condition and turbulent wall function were applied on each side of the thin surfaces. This approach simulated the swirl from the mixing devices well, but had the drawback of not predicting pressure drop accurately since the wake behind the plates and the acceleration effect of the spacers were ignored. CFDS-FLOW3D models with mixing devices were applied in the single-phase flow regime. Velocity profiles from the CFDS-FLOW3D models were compared to Laser Doppler Velocimeter measurements taken from the flow field downstream of spaces in a full scale, cold water test loop. The predicted axial and lateral velocity profiles were in good agreement with the measurements. The evaluation of the performance of different spacer devices was made by comparing the swirl ratio downstream of the grid spacers. It is planned to evaluate heat transfer coefficient downstream of the spaces, to implement two-phase flow models, and to model the superheated boundary layer on the surface of the fuel rod.

  10. Zircaloy spacer grid for boiling light water reactors

    International Nuclear Information System (INIS)

    Borgiani, F.; Cali', G.P.; Cerretti, P.; Pazzo, P.

    1975-01-01

    The need to increase the neutronic efficiency of the new cores of BWR's, lead to study types of spacer-grids made of low neutronic absorption materials as zircaloy-4. The particular mechanical behaviour of this material suggested to design a spacer-grids such as to utilize only blanking, slotting and bending operations as plastic forming and to avoid therefore drawing effects. The optimization of the bending procedures lead to a final spacer-grids configuration equally stiff in all directions and planes. Only for the ''elastic constraints'' nichel alloy sheets were used to made easy the whole spacer design. The ''rigid constraints'', supporting the rods, have been obtained directly from the spacer structure. Calculations were performed to verify the mechanical strength of the main grid components. In this framework a computer code was developed to find the best elastic characteristic of the ''elastic constraints'' taking into account the machining tolerances. Some original methods to test the integral behaviour of the grid assembled as well as the procedures to be adopted for its best maintenance, are described

  11. The effect of anterior longitudinal ligament resection on lordosis correction during minimally invasive lateral lumbar interbody fusion: Biomechanical and radiographic feasibility of an integrated spacer/plate interbody reconstruction device.

    Science.gov (United States)

    Kim, Choll; Harris, Jonathan A; Muzumdar, Aditya; Khalil, Saif; Sclafani, Joseph A; Raiszadeh, Kamshad; Bucklen, Brandon S

    2017-03-01

    Lateral lumbar interbody fusion is powerful for correcting degenerative conditions, yet sagittal correction remains limited by anterior longitudinal ligament tethering. Although lordosis has been restored via ligament release, biomechanical consequences remain unknown. Investigators examined radiographic and biomechanical of ligament release for restoration of lumbar lordosis. Six fresh-frozen human cadaveric spines (L3-S1) were tested: (Miller et al., 1988) intact; (Battie et al., 1995) 8mm spacer with intact anterior longitudinal ligament; (Cho et al., 2013) 8mm spacer without intact ligament following ligament resection; (Galbusera et al., 2013) 13mm lateral lumbar interbody fusion; (Goldstein et al., 2001) integrated 13mm spacer. Focal lordosis and range of motion were assessed by applying pure moments in flexion-extension, lateral bending, and axial rotation. Cadaveric radiographs showed significant improvement in lordosis correction following ligament resection (P0.05) but did little to restore lordosis. Ligament release significantly destabilized the spine relative to intact in all modes and 8mm with ligament in lateral bending and axial rotation (P0.05). Lordosis corrected by lateral lumbar interbody fusion can be improved by anterior longitudinal ligament resection, but significant construct instability and potential implant migration/dislodgment may result. This study shows that an added integrated lateral fixation system can significantly improve construct stability. Long-term multicenter studies are needed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Nanoparticle-Based Brachytherapy Spacers for Delivery of Localized Combined Chemoradiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Rajiv, E-mail: r.kumar@neu.edu [Nanomedicine Science and Technology Center, Northeastern University, Boston, Massachusetts (United States); Department of Radiation Oncology, Brigham and Women' s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts (United States); Belz, Jodi [Nanomedicine Science and Technology Center, Northeastern University, Boston, Massachusetts (United States); Markovic, Stacey [Department of Electrical and Computer Engineering, Northeastern University, Boston, Massachusetts (United States); Jadhav, Tej; Fowle, William [Nanomedicine Science and Technology Center, Northeastern University, Boston, Massachusetts (United States); Niedre, Mark [Department of Electrical and Computer Engineering, Northeastern University, Boston, Massachusetts (United States); Cormack, Robert; Makrigiorgos, Mike G. [Department of Radiation Oncology, Brigham and Women' s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts (United States); Sridhar, Srinivas [Nanomedicine Science and Technology Center, Northeastern University, Boston, Massachusetts (United States); Department of Radiation Oncology, Brigham and Women' s Hospital, Dana-Farber Cancer Institute and Harvard Medical School, Boston, Massachusetts (United States)

    2015-02-01

    Purpose: In radiation therapy (RT), brachytherapy-inert source spacers are commonly used in clinical practice to achieve high spatial accuracy. These implanted devices are critical technical components of precise radiation delivery but provide no direct therapeutic benefits. Methods and Materials: Here we have fabricated implantable nanoplatforms or chemoradiation therapy (INCeRT) spacers loaded with silica nanoparticles (SNPs) conjugated containing a drug, to act as a slow-release drug depot for simultaneous localized chemoradiation therapy. The spacers are made of poly(lactic-co-glycolic) acid (PLGA) as matrix and are physically identical in size to the commercially available brachytherapy spacers (5 mm × 0.8 mm). The silica nanoparticles, 250 nm in diameter, were conjugated with near infrared fluorophore Cy7.5 as a model drug, and the INCeRT spacers were characterized in terms of size, morphology, and composition using different instrumentation techniques. The spacers were further doped with an anticancer drug, docetaxel. We evaluated the in vivo stability, biocompatibility, and biodegradation of these spacers in live mouse tissues. Results: The electron microscopy studies showed that nanoparticles were distributed throughout the spacers. These INCeRT spacers remained stable and can be tracked by the use of optical fluorescence. In vivo optical imaging studies showed a slow diffusion of nanoparticles from the spacer to the adjacent tissue in contrast to the control Cy7.5-PLGA spacer, which showed rapid disintegration in a few days with a burst release of Cy7.5. The docetaxel spacers showed suppression of tumor growth in contrast to control mice over 16 days. Conclusions: The imaging with the Cy7.5 spacer and therapeutic efficacy with docetaxel spacers supports the hypothesis that INCeRT spacers can be used for delivering the drugs in a slow, sustained manner in conjunction with brachytherapy, in contrast to the rapid clearance of the drugs when

  13. Nanoparticle-Based Brachytherapy Spacers for Delivery of Localized Combined Chemoradiation Therapy

    International Nuclear Information System (INIS)

    Kumar, Rajiv; Belz, Jodi; Markovic, Stacey; Jadhav, Tej; Fowle, William; Niedre, Mark; Cormack, Robert; Makrigiorgos, Mike G.; Sridhar, Srinivas

    2015-01-01

    Purpose: In radiation therapy (RT), brachytherapy-inert source spacers are commonly used in clinical practice to achieve high spatial accuracy. These implanted devices are critical technical components of precise radiation delivery but provide no direct therapeutic benefits. Methods and Materials: Here we have fabricated implantable nanoplatforms or chemoradiation therapy (INCeRT) spacers loaded with silica nanoparticles (SNPs) conjugated containing a drug, to act as a slow-release drug depot for simultaneous localized chemoradiation therapy. The spacers are made of poly(lactic-co-glycolic) acid (PLGA) as matrix and are physically identical in size to the commercially available brachytherapy spacers (5 mm × 0.8 mm). The silica nanoparticles, 250 nm in diameter, were conjugated with near infrared fluorophore Cy7.5 as a model drug, and the INCeRT spacers were characterized in terms of size, morphology, and composition using different instrumentation techniques. The spacers were further doped with an anticancer drug, docetaxel. We evaluated the in vivo stability, biocompatibility, and biodegradation of these spacers in live mouse tissues. Results: The electron microscopy studies showed that nanoparticles were distributed throughout the spacers. These INCeRT spacers remained stable and can be tracked by the use of optical fluorescence. In vivo optical imaging studies showed a slow diffusion of nanoparticles from the spacer to the adjacent tissue in contrast to the control Cy7.5-PLGA spacer, which showed rapid disintegration in a few days with a burst release of Cy7.5. The docetaxel spacers showed suppression of tumor growth in contrast to control mice over 16 days. Conclusions: The imaging with the Cy7.5 spacer and therapeutic efficacy with docetaxel spacers supports the hypothesis that INCeRT spacers can be used for delivering the drugs in a slow, sustained manner in conjunction with brachytherapy, in contrast to the rapid clearance of the drugs when

  14. Methods and energy storage devices utilizing electrolytes having surface-smoothing additives

    Science.gov (United States)

    Xu, Wu; Zhang, Jiguang; Graff, Gordon L; Chen, Xilin; Ding, Fei

    2015-11-12

    Electrodeposition and energy storage devices utilizing an electrolyte having a surface-smoothing additive can result in self-healing, instead of self-amplification, of initial protuberant tips that give rise to roughness and/or dendrite formation on the substrate and anode surface. For electrodeposition of a first metal (M1) on a substrate or anode from one or more cations of M1 in an electrolyte solution, the electrolyte solution is characterized by a surface-smoothing additive containing cations of a second metal (M2), wherein cations of M2 have an effective electrochemical reduction potential in the solution lower than that of the cations of M1.

  15. Implementation of spacer therapy for acute asthma in children.

    LENUS (Irish Health Repository)

    Vandeleur, M

    2009-09-01

    The aim was to develop and implement an evidence based guideline for the treatment of acute asthma using a metered dose inhaler and spacer combination. Children admitted to Cork University Hospital Paediatric Department with acute asthma were identified during two identical 2 month seasonal periods before (2005) and after (2006) implementation of the new guidelines in September 2006. Pre-intervention and post-intervention audits by case note review were performed to determine the impact of and compliance with this evidence-based guideline emphasising patient assessment, spacer delivered bronchodilator and specific discharge criteria. Patients had similar characteristics during the two study periods. There was a raised threshold for admission after guideline implementation with 11\\/52 patients having mild exacerbations in 2006, compared to 21\\/36 in 2005. Duration of admission was less in the post-implementation group for equivalent exacerbation severity e.g. for moderate severity; 28 hours in 2005, 23 hours in 2006. Duration of bronchodilator therapy was shorter in 2006 and more likely to be given by spacer device earlier for equivalent levels of severity e.g. for moderate exacerbations, in 2006 the average length of salbutamol therapy was 18 hours with 12 hours by spacer device, in 2005 the average length of therapy was 25 hours with 3 hours by spacer. There was earlier initiation of oral corticosteroids; the average time to administration was 56 minutes in 2006 and 227 minutes in 2005. There was an improved documentation of asthma education in 2006 e.g. inhaler technique was reviewed in 37\\/52 in 2006, 21\\/35 in 2005 and better use of written action plans.

  16. Thermonuclear device

    International Nuclear Information System (INIS)

    Matsuyoshi, Hiroshi; Kiuchi, Teruo.

    1981-01-01

    Purpose: To effectively receive the large hoop force acting in a toroidal magnet coil conductor in a limited space by burying an electrical insulator spacer between confronting coil side surfaces. Constitution: Holes are opened at the confronting portions in space between magnet coil conductors each covered with confronting layer electrical insulators, an electrical insulator spacer is so inserted into the holes as to be partly buried, and the entirety is covered with earth insulators and hardened. Thus, the inner space between the coil conductors can be effectively utilized, the spacer plugs the holes, and when the spacer is independently mechanically machined, it can be engaged within the holes of the coil conductors with high accuracy, so that hoop force produced in the coil conductors can be reliably received by utilizing the space between the coil conductors. (Yoshino, Y.)

  17. Health state utilities associated with attributes of weekly injection devices for treatment of type 2 diabetes

    Directory of Open Access Journals (Sweden)

    Louis S. Matza

    2017-11-01

    Full Text Available Abstract Background Glucagon-like peptide-1 (GLP-1 receptor agonists are often recommended as part of combination therapy for type 2 diabetes when oral medication does not result in sufficient glycemic control. Several GLP-1 receptor agonists are available as weekly injections. These medications vary in their injection delivery systems, and these differences could impact quality of life and treatment preference. The purpose of this study was to estimate utilities associated with attributes of injection delivery systems for weekly GLP-1 therapies. Methods Participants with type 2 diabetes in the UK valued health states in time trade-off interviews. The health states (drafted based on literature, device instructions for use, and clinician interviews had identical descriptions of type 2 diabetes, but differed in description of the treatment process. One health state described oral treatment, while six others described oral treatment plus a weekly injection. The injection health states varied in three aspects of the treatment administration process: requirements for reconstituting the medication (i.e., mixing the medication prior to the injection, waiting during medication preparation, and needle handling. Every participant valued all seven health states. Results A total of 209 participants completed interviews (57.4% male; mean age = 60.4y. The mean utility of the oral treatment health state was 0.89. All injection health states had significantly (p < 0.01 lower utilities ranging from 0.86 to 0.88. Differences among health state utilities suggest that each administration requirement had a small but measureable disutility: -0.004 (reconstitution, -0.004 (needle handling, -0.010 (reconstitution, needle handling, and -0.020 (reconstitution, waiting, needle handling. Conclusions Findings suggest it is feasible to use the TTO method to quantify preferences among injection treatment processes. It may be useful to incorporate these utility differences

  18. Does Semi-Rigid Instrumentation Using Both Flexion and Extension Dampening Spacers Truly Provide an Intermediate Level of Stabilization?

    Directory of Open Access Journals (Sweden)

    Dilip Sengupta

    2013-01-01

    Full Text Available Conventional posterior dynamic stabilization devices demonstrated a tendency towards highly rigid stabilization approximating that of titanium rods in flexion. In extension, they excessively offload the index segment, making the device as the sole load-bearing structure, with concerns of device failure. The goal of this study was to compare the kinematics and intradiscal pressure of monosegmental stabilization utilizing a new device that incorporates both a flexion and extension dampening spacer to that of rigid internal fixation and a conventional posterior dynamic stabilization device. The hypothesis was the new device would minimize the overloading of adjacent levels compared to rigid and conventional devices which can only bend but not stretch. The biomechanics were compared following injury in a human cadaveric lumbosacral spine under simulated physiological loading conditions. The stabilization with the new posterior dynamic stabilization device significantly reduced motion uniformly in all loading directions, but less so than rigid fixation. The evaluation of adjacent level motion and pressure showed some benefit of the new device when compared to rigid fixation. Posterior dynamic stabilization designs which both bend and stretch showed improved kinematic and load-sharing properties when compared to rigid fixation and when indirectly compared to existing conventional devices without a bumper.

  19. Two pion correlation from SPACER

    International Nuclear Information System (INIS)

    Csoergoe, T.; Zimanyi, J.; Pratt, S.

    1989-12-01

    The correlation function for neutral and negative pions produced in ultrarelativistic heavy ion collisions was calculated without free parameters based on a space-time version of the LUND model, called SPACER: Simulation of Phase space distribution of Atomic nuclear Collisions in Energetic Reactions. This method includes the effect of Bose correlations for the emitted pion pair. Effects arising from correlations between space-time and momentum space distributions are investigated. The results are compared to the data of two different experiments. The role and interpretation of the chaocity parameter are discussed. (D.G.) 14 refs.; 4 figs

  20. Spacers for fuel rod clusters

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1978-01-01

    The proposition deals with the fixing of nuclear fuel element rods in a grid which consists of a number of crossed Zy-plates which form cells. The rectangular cells have projections which serve as spacers for the fuel rods. According to the invention there are additional butt straps which can be moved in such a way that insertion and extraction of the fuel rods can be done without obstruction and they can be spring-loaded hold in their final position. (UWI) [de

  1. The use of ZnO as optical spacer in polymer solar cells : theoretical and experimental study

    NARCIS (Netherlands)

    Gilot, J.; Barbu, I.; Wienk, M.M.; Janssen, R.A.J.

    2007-01-01

    For org. solar cells, insertion of an optical spacer between the active layer and the reflective electrode results in a redistribution of the optical elec. field. In this paper, theor. calcns. using optical modeling are compared with exptl. results for devices with ZnO as optical spacer. An

  2. Development of a High Performance Spacer Grid

    Energy Technology Data Exchange (ETDEWEB)

    Song, Kee Nam; Song, K. N.; Yoon, K. H. (and others)

    2007-03-15

    A spacer grid in a LWR fuel assembly is a key structural component to support fuel rods and to enhance the heat transfer from the fuel rod to the coolant. In this research, the main research items are the development of inherent and high performance spacer grid shapes, the establishment of mechanical/structural analysis and test technology, and the set-up of basic test facilities for the spacer grid. The main research areas and results are as follows. 1. 18 different spacer grid candidates have been invented and applied for domestic and US patents. Among the candidates 16 are chosen from the patent. 2. Two kinds of spacer grids are finally selected for the advanced LWR fuel after detailed performance tests on the candidates and commercial spacer grids from a mechanical/structural point of view. According to the test results the features of the selected spacer grids are better than those of the commercial spacer grids. 3. Four kinds of basic test facilities are set up and the relevant test technologies are established. 4. Mechanical/structural analysis models and technology for spacer grid performance are developed and the analysis results are compared with the test results to enhance the reliability of the models.

  3. How to use an inhaler - no spacer

    Science.gov (United States)

    ... MDI) administration - no spacer; Bronchial nebulizer; Wheezing - nebulizer; Reactive airway - nebulizer; COPD - ... 66. National Asthma Education and Prevention Program website. How to use a metered-dose inhaler. ...

  4. Endoscopic repair of an injured internal carotid artery utilizing femoral endovascular closure devices.

    Science.gov (United States)

    Van Rompaey, Jason; Bowers, Greg; Radhakrishnan, Jay; Panizza, Benedict; Solares, C Arturo

    2014-06-01

    Injury to the internal carotid artery is a feared complication of endoscopic endonasal surgery of the skull base. Such an event, although rare, is associated with high morbidity and mortality. Even if bleeding is controlled, permanent neurological defects frequently persist. Many techniques have been developed to manage internal carotid artery rupture with varying degrees of success. The purpose of this study was to explore endoscopic management of arterial damage with endovascular closure devices used for a femoral arteriotomy. The ability to remotely suture a damaged artery permits the possible adaptation of this technology in managing endoscopic arterial complications. Technical note. After the creation of an endoscopic endonasal corridor in a cadaveric specimen, an arteriotomy was created at the cavernous portion of the internal carotid artery. The Angio-Seal, StarClose, and MynxGrip vascular closure devices were utilized under endoscopic guidance to repair the arteriotomy. Angiography was then done on a cadaver sutured with the StarClose. Both the Angio-Seal and StarClose were deployed quickly and appeared to provide sufficient closure of the arteriotomy. The Angio-Seal required the use of a guidewire and was longer to deploy when compared with the StarClose. The StarClose deployment was quick and facile. The MynxGrip also deployed without difficulty. The Angio-Seal and StarClose systems were both successfully deployed utilizing an endoscopic endonasal approach. The MynxGrip was the easiest to deploy and has the greatest potential to be of benefit in this application. Further studies with hemodynamic models are required to properly assess the appropriateness in this setting. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Device with Complex System for Heat Utilization and Reduction of Hazardous Air Emissions

    Directory of Open Access Journals (Sweden)

    O. V. Kascheeva

    2012-01-01

    Full Text Available Investigations concern heat utilization and reduction of hazardous emissions occurring in residential buildings and accompanying operation of a great number of industrial enterprises in particular heat and power objects, and firstly, heat-generating units of small power located in densely populated residential areas without centralized heat supply.The investigation target is to reduce cost of heat produced by independent system of building heat supply, reduction of air pollution  due to hazardous gas emissions and reduction of heat pollution of the environment as a result of building ventilation system operation, ventilation of their internal and external sewerage network and higher reliability of their operation.The target is achieved because the device with complex system for heat utilization and reduction of hazardous air emissions has additionally an assembly tank for mixing flue gases, ventilation emissions and atmospheric air, heat pump. Evaporation zone of the pump is a condensator of the gas mixture and its condensate zone contains a heat supply line for a heat consumer. The line is equipped with assembling  and distributing collectors, pipeline connecting the heat supply line with the system of direct and return delivery water from a boiler house, a separator for division of liquid and gaseous mixture phases, neutralizing devices for separate reduction of concentrations of hazardous and odorous substances being released in gaseous and liquid portions of the mixture, a pipeline for periodic supply of air with higher concentration of hazardous and odorous substances in the boiler furnace. The supplied air is obtained as a result of its passing through gas filters at their regeneration when their exchange capacity is exhausted.

  6. Additional collection devices used in conjunction with the SurePath Liquid-Based Pap Test broom device do not enhance diagnostic utility

    Directory of Open Access Journals (Sweden)

    O'Connor Jason C

    2004-09-01

    Full Text Available Abstract Background We have previously shown that use of an EC brush device in combination with the Rovers Cervex-Brush (SurePath broom offered no significant improvement in EC recovery. Here we determine if use of additional collection devices enhance the diagnostic utility of the SurePath Pap for gynecologic cytology. Methods After informed consent, 37 women ages 18–56 receiving their routine cervical examinations were randomized into four experimental groups. Each group was first sampled with the SurePath broom then immediately re-sampled with an additional collection device or devices. Group 1: Rover endocervix brush (n = 8. Group 2: Medscand CytoBrush Plus GT (n = 7. Group 3: Rover spatula + endocervix brush (n = 11. Group 4: Medscand spatula + CytoBrush Plus GT (n = 11. Results Examination of SurePath broom-collected cytology yielded the following abnormal diagnoses: atypia (n = 2, LSIL (n = 5 and HSIL (n = 3. Comparison of these diagnoses to those obtained from paired samples using the additional collection devices showed that use of a second and or third device yielded no additional abnormal diagnoses. Importantly, use of additional devices did not improve upon the abnormal cell recovery of the SurePath broom and in 4/10 cases under-predicted or did not detect the SurePath broom-collected lesion as confirmed by cervical biopsy. Finally, in 36/37 cases, the SurePath broom successfully recovered ECs. Use of additional devices, in Group 3, augmented EC recovery to 37/37. Conclusions Use of additional collection devices in conjunction with the SurePath broom did not enhance diagnostic utility of the SurePath Pap. A potential but not significant improvement in EC recovery might be seen with the use of three devices.

  7. A microfluidic device for separation of amniotic fluid mesenchymal stem cells utilizing louver-array structures.

    Science.gov (United States)

    Wu, Huei-Wen; Lin, Xi-Zhang; Hwang, Shiaw-Min; Lee, Gwo-Bin

    2009-12-01

    Human mesenchymal stem cells can differentiate into multiple lineages for cell therapy and, therefore, have attracted considerable research interest recently. This study presents a new microfluidic device for bead and cell separation utilizing a combination of T-junction focusing and tilted louver-like structures. For the first time, a microfluidic device is used for continuous separation of amniotic stem cells from amniotic fluids. An experimental separation efficiency as high as 82.8% for amniotic fluid mesenchymal stem cells is achieved. Furthermore, a two-step separation process is performed to improve the separation efficiency to 97.1%. These results are based on characterization experiments that show that this microfluidic chip is capable of separating beads with diameters of 5, 10, 20, and 40 microm by adjusting the volume-flow-rate ratio between the flows in the main and side channels of the T-junction focusing structure. An optimal volume-flow-rate ratio of 0.5 can lead to high separation efficiencies of 87.8% and 85.7% for 5-microm and 10-microm beads, respectively, in a one-step separation process. The development of this microfluidic chip may be promising for future research into stem cells and for cell therapy.

  8. Utility of mobile devices in the computerized tomography evaluation of intracranial hemorrhage

    International Nuclear Information System (INIS)

    Panughpath, Sridhar G; Kumar, Savith; Kalyanpur, Arjun

    2013-01-01

    To evaluate the utility of a mobile device to detect and assess intracranial hemorrhage (ICH) on head computed tomographys (CT) performed in the emergency setting. 100 head CT scans were randomly selected from our emergency radiology database and anonymized for patient demographics and clinical history. The studies were independently interpreted by two experienced radiologists in a blinded manner, initially on a mobile device (iPad, Apple computers) and subsequently, at an interval of one week, on a regular desktop workstation. Evaluation was directed towards detection, localization and characterization of hemorrhage. The results were assessed for accuracy, sensitivity, specificity and positive predictive value. Statistical significance was ascertained using Fisher's exact test. 27 of the examinations were positive for ICH, of which 11 had multiple hemorrhages. Of these there were 17 subdural, 18 intraparenchymal, 8 subarachnoid, 4 intraventricular and 2 extradural hemorrhages. In 96 of the studies there was complete concurrence between the iPad and desktop interpretations for both radiologists. Of 49 hemorrhages, 48 were accurately detected on the iPad by one of the radiologists. In the remaining case, a tiny intraventricular hemorrhage was missed by both radiologists on the iPad as well as on the workstation, indicating that the miss was more likely related to the very small size of the hemorrhage than the viewer used. We conclude that in the emergency setting, a mobile device with appropriate web-based pictue archiving and communication system (PACS) is effective in the detection of intracranial hemorrhage present on head CT

  9. Utility of mobile devices in the computerized tomography evaluation of intracranial hemorrhage

    Directory of Open Access Journals (Sweden)

    Sridhar G Panughpath

    2013-01-01

    Full Text Available Aim: To evaluate the utility of a mobile device to detect and assess intracranial hemorrhage (ICH on head computed tomographys (CT performed in the emergency setting. Materials and Methods: 100 head CT scans were randomly selected from our emergency radiology database and anonymized for patient demographics and clinical history. The studies were independently interpreted by two experienced radiologists in a blinded manner, initially on a mobile device (iPad, Apple computers and subsequently, at an interval of one week, on a regular desktop workstation. Evaluation was directed towards detection, localization and characterization of hemorrhage. The results were assessed for accuracy, sensitivity, specificity and positive predictive value. Statistical significance was ascertained using Fisher′s exact test. Results: 27 of the examinations were positive for ICH, of which 11 had multiple hemorrhages. Of these there were 17 subdural, 18 intraparenchymal, 8 subarachnoid, 4 intraventricular and 2 extradural hemorrhages. In 96 of the studies there was complete concurrence between the iPad and desktop interpretations for both radiologists. Of 49 hemorrhages, 48 were accurately detected on the iPad by one of the radiologists. In the remaining case, a tiny intraventricular hemorrhage was missed by both radiologists on the iPad as well as on the workstation, indicating that the miss was more likely related to the very small size of the hemorrhage than the viewer used. Conclusion: We conclude that in the emergency setting, a mobile device with appropriate web-based pictue archiving and communication system (PACS is effective in the detection of intracranial hemorrhage present on head CT.

  10. Spacer for supporting fuel element boxes

    International Nuclear Information System (INIS)

    Wild, E.

    1979-01-01

    A spacer plate unit arranged externally on each side and at a predetermined level of a polygonal fuel element box for mutually supporting, with respect to one another, a plurality of the fuel element boxes forming a fuel element bundle, is formed of a first and a second spacer plate part each having the same length and the same width and being constituted of unlike first and second materials, respectively. The first and second spacer plate parts of the several spacer plate units situated at the predetermined level are arranged in an alternating continuous series when viewed in the peripheral direction of the fuel element box, so that any two spacer plate units belonging to face-to-face oriented sides of two adjoining fuel element boxes in the fuel element bundle define interfaces of unlike materials

  11. Evaluation of spacer grid spring characteristics by means of physical tests and numerical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Schettino, Carlos Frederico Mattos, E-mail: carlosschettino@inb.gov.br [Industrias Nucleares do Brasil (INB), Resende, RJ (Brazil)

    2017-11-01

    Among all fuel assemblies' components, the spacer grids play an important structural role during the energy generation process, mainly due for its primary functional requirement, that is, to provide fuel rod support. The present work aims to evaluate the spring characteristics of a specific spacer grid design used in a PWR fuel assembly type 16 x 16. These spring characteristics comprises the load versus deflection capability and its spring rate, which are very important, and also mandatory, to be correctly established in order to preclude spacer grid spring and fuel rod cladding fretting during operation, as well as prevent an excessive fuel rod buckling. This study includes physical tests and numerical simulation. The tests were performed on an adapted load cell mechanical device, using as a specimen a single strap of the spacer grid. Three numerical models were prepared using the Finite Element Method, with the support of the commercial code ANSYS. One model was built to validate the simulation according to the performed physical test, the others were built inserting a gradient of temperature (Beginning Of Life hot condition) and to evaluate the spacer grid spring characteristics in End Of Life condition. The obtained results from physical test and numerical model have shown a good agreement between them, therefore validating the simulation. The obtained results from numerical models make available information regarding the spacer grid design purpose, such as the behavior of the fuel rod cladding support during operation. Therewith, these evaluations could be useful to improve the spacer grid design. (author)

  12. Evaluation of spacer grid spring characteristics by means of physical tests and numerical simulation

    International Nuclear Information System (INIS)

    Schettino, Carlos Frederico Mattos

    2017-01-01

    Among all fuel assemblies' components, the spacer grids play an important structural role during the energy generation process, mainly due for its primary functional requirement, that is, to provide fuel rod support. The present work aims to evaluate the spring characteristics of a specific spacer grid design used in a PWR fuel assembly type 16 x 16. These spring characteristics comprises the load versus deflection capability and its spring rate, which are very important, and also mandatory, to be correctly established in order to preclude spacer grid spring and fuel rod cladding fretting during operation, as well as prevent an excessive fuel rod buckling. This study includes physical tests and numerical simulation. The tests were performed on an adapted load cell mechanical device, using as a specimen a single strap of the spacer grid. Three numerical models were prepared using the Finite Element Method, with the support of the commercial code ANSYS. One model was built to validate the simulation according to the performed physical test, the others were built inserting a gradient of temperature (Beginning Of Life hot condition) and to evaluate the spacer grid spring characteristics in End Of Life condition. The obtained results from physical test and numerical model have shown a good agreement between them, therefore validating the simulation. The obtained results from numerical models make available information regarding the spacer grid design purpose, such as the behavior of the fuel rod cladding support during operation. Therewith, these evaluations could be useful to improve the spacer grid design. (author)

  13. Energy Saving Performance Analysis of An Inverter-based Regenerative Power Re-utilization Device for Urban Rail Transit

    Science.gov (United States)

    Li, Jin; Qiu, Zhiling; Hu, Leilei

    2018-04-01

    The inverter-based regenerative braking power utilization devices can re-utilize the regenerative energy, thus reduce the energy consumption of urban rail transit. In this paper the power absorption principle of the inverter-based device is introduced, then the key influencing factors of energy saving performance are analyzed based on the absorption model. The field operation data verified that the control DC voltage plays an important role and lower control DC voltage yields more energy saving. Also, the one year energy saving performance data of an inverter-based re-utilization device located in NanJing S8 line is provided, and more than 1.2 million kWh energy is recovered in the one year operation.

  14. A simulation methodology of spacer grid residual spring deflection for predictive and interpretative purposes

    International Nuclear Information System (INIS)

    Kim, K. T.; Kim, H. K.; Yoon, K. H.

    1994-01-01

    The in-reactor fuel rod support conditions against the fretting wear-induced damage can be evaluated by spacer grid residual spring deflection. In order to predict the spacer grid residual spring deflection as a function of burnup for various spring designs, a simulation methodology of spacer grid residual spring deflection has been developed and implemented in the GRIDFORCE program. The simulation methodology takes into account cladding creep rate, initial spring deflection, initial spring force, and spring force relaxation rate as the key parameters affecting the residual spring deflection. The simulation methodology developed in this study can be utilized as an effective tool in evaluating the capability of a newly designed spacer grid spring to prevent the fretting wear-induced damage

  15. Propellantless Attitude Control of Solar Sail Technology Utilizing Reflective Control Devices

    Science.gov (United States)

    Munday, Jeremy

    2016-01-01

    Solar sails offer an opportunity for a CubeSatscale, propellant-free spacecraft technology that enables long-term and long-distance missions not possible with traditional methods. Solar sails operate using the transfer of linear momentum from photons of sunlight reflected from the surface of the sail. To propel the spacecraft, no mechanically moving parts, thrusters, or propellant are needed. However, attitude control, or orientation, is still performed using traditional methods involving reaction wheels and propellant ejection, which severely limit mission lifetime. For example, the current state of the art solutions employed by upcoming missions couple solar sails with a state of the art propellant ejection gas system. Here, the use of the gas thruster has limited the lifetime of the mission. To solve the limited mission lifetime problem, the Propellantless Attitude Control of Solar Sail Technology Utilizing Reflective Control Devices project team is working on propellantless attitude control using thin layers of material, an optical film, electrically switchable from transparent to reflective. The technology is based on a polymer-dispersed liquid crystal (PDLC), which allows this switch upon application of a voltage. This technology removes the need for propellant, which reduces weight and cost while improving performance and lifetime.

  16. Fouling Resilient Perforated Feed Spacers for Membrane Filtration

    KAUST Repository

    Kerdi, Sarah; Qamar, Adnan; Vrouwenvelder, Johannes S.; Ghaffour, NorEddine

    2018-01-01

    drop across the spacer filled channel. The 3-Hole spacer was found to have the lowest pressure drop (50% - 61%) compared to 0-Hole spacer for various average flow velocities. Regarding permeate flux production, the 0-Hole spacer produced 5.7 L.m-2.h-1

  17. Clinical utility of scintimammography: From the Anger-camera to new dedicated devices

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy)]. E-mail: oschil@tiscali.it; Danieli, Roberta [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Romano, Pasquale [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Cossu, Elsa [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy)

    2006-12-20

    Scintimammography is a functional imaging technique which uses a radiation detection camera to detect radionuclide tracers in the patient's breasts. Tracers are designed to accumulate in tumours more than in healthy tissue: the most used are Tc-99 m sestamibi and Tc-99 m tetrofosmin. Scintimammography is useful in some clinical indications as an adjunct to mammography: it is recommended for those lesions where additional information is required to reach a definitive diagnosis. Patients with dubious mammograms may benefit from this test, as well as women with dense breasts or with implants. Scintimammography is a valuable diagnostic tool also in patients with locally advanced breast cancer for monitoring and predicting response to neoadjuvant chemotherapy. Nevertheless, using an Anger-camera this technique shows a high sensitivity only for cancers >1 cm. Since other modalities are increasingly employed for the early identification of small abnormalities, the issue of detecting small cancers is critical for the future development and clinical utility of breast imaging with radiopharmaceuticals. The use of high-resolution cameras dedicated for breast imaging is the best option to improve the detection of small cancers: they allow higher flexibility in patient positioning, and the availability of mammography-like projections. Moreover, the detector can be placed directly in contact with the breast allowing a mild compression with reduction of the breast's thickness, thus increasing the target-to-background ratio and the sensitivity. These new devices have the potential of increasing the total number of breast scintigraphies performed thereby enhancing the role of nuclear medicine in breast cancer imaging.

  18. Study on Waste Heat Utilization Device of High-Temperature Freshwater in the Modern Marine Diesel Engine

    Science.gov (United States)

    Wang, Shuaijun; Liu, Chentao; Zhou, Yao

    2018-01-01

    Based on using the waste heat recycling from high temperature freshwater in marine diesel engine to heat fuel oil tank, lubrication oil tank and settling tank and so on to achieve energy saving, improve fuel efficiency as the goal, study on waste heat utilization device of high-temperature freshwater in the modern marine diesel engine to make the combustion chamber effectively cooled by high-temperature freshwater and the inner liner freshwater temperature heat is effectively utilized and so on to improve the overall efficiency of the power plant of the ship and the diesel optimum working condition.

  19. High corrosion-resistant fuel spacers

    International Nuclear Information System (INIS)

    Yoshida, Toshimi; Takase, Iwao; Ikeda, Shinzo; Masaoka, Isao; Nakajima, Junjiro.

    1986-01-01

    Purpose: To enable manufacturing BWR fuel spacers by prior-art production process, using a zirconium-base alloy having very excellent corrosion resistance. Method: A highly improved nodular-resistant, corrosion-resistant zirconium alloy is devised by adding a slight amount of niobium, titanium and vanadium to zircaloy, of which fuel spacers are produced. That is, there can be obtained an alloy having much more excellent nodular resistance than conventional zircaloy, and free from a large change in plasticity, workability, and weldability, by adding to zirconium about 1.5 % of tin, about 0.15 % of iron, about 0.05 % of chromium, about 0.05 % of nickel, and 0.05 to 0.5 % of at least one or two kinds of niobium, titanium and vanadium. Using this zirconium-base alloy can manufacture fuel spacers by the same manufacturing process, thus improving economy and reliability. (Kamimura, M.)

  20. Barriers and supports to implementation of MDI/spacer use in nine Canadian pediatric emergency departments: a qualitative study

    Directory of Open Access Journals (Sweden)

    Graham Ian D

    2009-10-01

    Full Text Available Abstract Background Despite recent research supporting the use of metered dose inhalers with spacer devices (MDI/spacers in pediatric emergency departments (PEDs for acute exacerbations of asthma, uptake of this practice has been slow. The objectives of this study were to determine the barriers and supports to implementing MDI/spacer research and to identify factors associated with early and late adoption of MDI/spacers in Canadian PEDs. Methods Using a comparative case study design, we classified nine tertiary care pediatric hospital PEDs based on their stage of implementation. Data were collected using focus group interviews with physicians, registered nurses (RNs, and respiratory therapists (RTs, and individual interviews with both patient care and medical directors at each site. Initial coding was based on the Ottawa Model of Research Use (OMRU categories of elements known to influence the uptake of innovations. Results One hundred and fifty healthcare professionals from nine different healthcare institutions participated in this study. Lack of leadership in the form of a research champion, a lack of consensus about the benefits of MDI/spacers among staff, perceived resistance from patients/parents, and perceived increased cost and workload associated with MDI/spacer use were the most prevalent barriers to the adoption of the MDI/spacer. Common strategies used by early-adopting sites included the active participation of all professional groups in the adoption process in addition to a well-planned and executed educational component for staff, patients, and families. Early adopter sites were also more likely to have the MDI/spacer included in a clinical protocol/pathway. Conclusion Potential barriers and supports to implementation have been identified that will help EDs adopt MDI/spacer use. Future interventions intended to increase MDI/spacer use in PEDs will need to be sensitive to the barriers identified in this study.

  1. Simulation study of transfer characteristics for spacer-filled membrane distillation desalination modules

    International Nuclear Information System (INIS)

    Chang, Hsuan; Hsu, Jian-An; Chang, Cheng-Liang; Ho, Chii-Dong; Cheng, Tung-Wen

    2017-01-01

    Highlights: • A 3D CFD model takes in transmembrane heat and mass transfer developed. • DCMD modules using spacer-filled and empty channels for desalination simulated. • Fluid flow, heat transfer and mass transfer profiles revealed. • Correlations of friction factor and Nusselt number developed. - Abstract: Membrane distillation (MD) is an emerging and promising membrane separation process, which can directly utilize renewable thermal energy or low-grade waste heat, for applications in water or wastewater treatment and food industry. However, a major drawback of MD process is its low energy efficiency. Spacer is the most suggested and studied eddy promoter to enhance the heat and mass transfer, which further improves both the separation and the energy utilization performance, of MD processes. This paper presents the results of a 3D computational fluid dynamics (CFD) simulation of DCMD (direct contact membrane distillation) modules using channels with and without spacers for desalination application. The model employs permeable wall boundary condition to take into account the transmembrane heat and mass transfer and simulates the entire module length. The simulation reveals similar fluctuating distributions of temperature polarization coefficient, transmembrane heat and mass fluxes as well as the shear stress on the membrane surface along the entire module length. Correlations have been developed for friction factor and average Nusselt number. These correlations are useful for the analysis and design of DCMD modules. The extent of heat transfer enhancement by spacers depends on the geometry of spacers and the Reynolds number of fluid.

  2. Improved outcoupling of light in organic light emitting devices, utilizing a holographic DFB-structure

    Energy Technology Data Exchange (ETDEWEB)

    Reinke, Nils [Organische Funktionsmaterialien, University of Duisburg-Essen (Germany)]. E-mail: nils.reinke@physik.uni-augsburg.de; Fuhrmann, Thomas [Macromolecular Chemistry and Molecular Materials, University of Kassel (Germany); Perschke, Alexandra [Organische Funktionsmaterialien, University of Duisburg-Essen (Germany); Franke, Hilmar [Organische Funktionsmaterialien, University of Duisburg-Essen (Germany)

    2004-12-10

    In this work organic light emitting devices (OLEDs) were fabricated implementing gratings, in order to extract waveguided electroluminescence (EL). The gratings were recorded by exposing thin films of the molecular azo glass N, N'-bis (4-phenyl)-N, N'-bis [(4-phenylazo)-phenyl] benzidine (AZOPD) to holographic light patterns. The photopatterned AZOPD serves as hole transport material for devices with aluminum-tris(8-hydroxyquinoline) doped with 1% of 4-(dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran (Alq{sub 3}:DCM) as emissive/electron transport layer. The corrugated devices showed enhanced emission in the forward direction. The emitted light is polarized preferably parallel to the grating lines. In addition, we have found a doubling in the total luminance with respect to the unstructured device.

  3. Utilization of photoconductive gain in a-Si:H devices for radiation detection

    International Nuclear Information System (INIS)

    Lee, H.K.; Drewery, J.S.; Hong, W.S.; Jing, T.; Kaplan, S.N.; Perez-Mendez, V.

    1995-05-01

    The photoconductive gain mechanism in a-Si:H was investigated in connection with applications to radiation detection. Various device types such as p-i-n, n-i-n and n-i-p-i-n structures were fabricated and tested. Photoconductive gain was measured in two time scales: one for short pulses of visible light ( 2 . Various gain results are discussed in terms of the device structure, applied bias and dark current

  4. Portable (handheld) clinical device for quantitative spectroscopy of skin, utilizing spatial frequency domain reflectance techniques

    Science.gov (United States)

    Saager, Rolf B.; Dang, An N.; Huang, Samantha S.; Kelly, Kristen M.; Durkin, Anthony J.

    2017-09-01

    Spatial Frequency Domain Spectroscopy (SFDS) is a technique for quantifying in-vivo tissue optical properties. SFDS employs structured light patterns that are projected onto tissues using a spatial light modulator, such as a digital micromirror device. In combination with appropriate models of light propagation, this technique can be used to quantify tissue optical properties (absorption, μa, and scattering, μs', coefficients) and chromophore concentrations. Here we present a handheld implementation of an SFDS device that employs line (one dimensional) imaging. This instrument can measure 1088 spatial locations that span a 3 cm line as opposed to our original benchtop SFDS system that only collects a single 1 mm diameter spot. This imager, however, retains the spectral resolution (˜1 nm) and range (450-1000 nm) of our original benchtop SFDS device. In the context of homogeneous turbid media, we demonstrate that this new system matches the spectral response of our original system to within 1% across a typical range of spatial frequencies (0-0.35 mm-1). With the new form factor, the device has tremendously improved mobility and portability, allowing for greater ease of use in a clinical setting. A smaller size also enables access to different tissue locations, which increases the flexibility of the device. The design of this portable system not only enables SFDS to be used in clinical settings but also enables visualization of properties of layered tissues such as skin.

  5. Utility of a simple lighting device to improve chest compressions learning.

    Science.gov (United States)

    González-Calvete, L; Barcala-Furelos, R; Moure-González, J D; Abelairas-Gómez, C; Rodríguez-Núñez, A

    2017-11-01

    The recommendations on cardiopulmonary resuscitation (CPR) emphasize the quality of the manoeuvres, especially chest compressions (CC). Audiovisual feedback devices could improve the quality of the CC during CPR. The aim of this study was to evaluate the usefulness of a simple lighting device as a visual aid during CPR on a mannequin. Twenty-two paediatricians who attended an accredited paediatric CPR course performed, in random order, 2min of CPR on a mannequin without and with the help of a simple lighting device, which flashes at a frequency of 100 cycles per minute. The following CC variables were analyzed using a validated compression quality meter (CPRmeter ® ): depth, decompression, rate, CPR time and percentage of compressions. With the lighting device, participants increased average quality (60.23±54.50 vs. 79.24±9.80%; P=.005), percentage in target depth (48.86±42.67 vs. 72.95±20.25%; P=.036) and rate (35.82±37.54 vs. 67.09±31.95%; P=.024). A simple light device that flashes at the recommended frequency improves the quality of CC performed by paediatric residents on a mannequin. The usefulness of this CPR aid system should be assessed in real patients. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Fouling Resilient Perforated Feed Spacers for Membrane Filtration

    KAUST Repository

    Kerdi, Sarah

    2018-04-24

    The improvement of feed spacers with optimal geometry remains a key challenge for spiral-wound membrane systems in water treatment due to their impact on the hydrodynamic performance and fouling development. In this work, novel spacer designs are proposed by intrinsically modifying cylindrical filaments through perforations. Three symmetric perforated spacers (1-Hole, 2-Hole, and 3-Hole) were in-house 3D-printed and experimentally evaluated in terms of permeate flux, feed channel pressure drop and membrane fouling. Spacer performance is characterized and compared with standard no perforated (0-Hole) design under constant feed pressure and constant feed flow rate. Perforations in the spacer filaments resulted in significantly lowering the net pressure drop across the spacer filled channel. The 3-Hole spacer was found to have the lowest pressure drop (50% - 61%) compared to 0-Hole spacer for various average flow velocities. Regarding permeate flux production, the 0-Hole spacer produced 5.7 L.m-2.h-1 and 6.6 L.m-2.h-1 steady state flux for constant pressure and constant feed flow rate, respectively. The 1-Hole spacer was found to be the most efficient among the perforated spacers with 75% and 23% increase in permeate production at constant pressure and constant feed flow, respectively. Furthermore, membrane surface of 1-Hole spacer was found to be cleanest in terms of fouling, contributing to maintain higher permeate flux production. Hydrodynamic understanding of these perforated spacers is also quantified by performing Direct Numerical Simulation (DNS). The performance enhancement of these perforated spacers is attributed to the formation of micro-jets in the spacer cell that aided in producing enough unsteadiness/turbulence to clean the membrane surface and mitigate fouling phenomena. In the case of 1-Hole spacer, the unsteadiness intensity at the outlet of micro-jets and the shear stress fluctuations created inside the cells are higher than those observed with

  7. Hydrogel Spacer Prospective Multicenter Randomized Controlled Pivotal Trial: Dosimetric and Clinical Effects of Perirectal Spacer Application in Men Undergoing Prostate Image Guided Intensity Modulated Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Mariados, Neil, E-mail: nmariados@ampofny.com [Associated Medical Professionals of New York, Syracuse, New York (United States); Sylvester, John [21st Century Oncology, East Bradenton, Florida (United States); Shah, Dhiren [Western New York Urology Associates, Cancer Care of WNY, Cheektowaga, New York (United States); Karsh, Lawrence [The Urology Center of Colorado, Denver, Colorado (United States); Hudes, Richard [Chesapeake Urology Research Associates, The Prostate Center, Owings Mills, Maryland (United States); Beyer, David [Arizona Oncology Services Foundation, Phoenix, Arizona (United States); Kurtzman, Steven [Urological Surgeons of Northern California, Campbell, California (United States); Bogart, Jeffrey [The Research Foundation of State University of New York, SUNY Upstate Medical University, Syracuse, New York (United States); Hsi, R. Alex [Peninsula Cancer Center, Poulsbo, Washington (United States); Kos, Michael [Urology Nevada, Reno, Nevada (United States); Ellis, Rodney [University Hospitals Case Medical Center, Cleveland, Ohio (United States); Logsdon, Mark [Sutter Health Sacramento Sierra Region, Sutter Institute for Medical Research, Sacramento, California (United States); Zimberg, Shawn [Advanced Radiation Centers of New York, Lake Success, New York (United States); Forsythe, Kevin [Oregon Urology Institute, Springfield, Oregon (United States); Zhang, Hong [University of Rochester, Rochester, New York (United States); Soffen, Edward [CentraState Medical Center, Freehold, New Jersey (United States); Francke, Patrick [Carolina Regional Cancer Center, 21st Century Oncology, Myrtle Beach, South Carolina (United States); Mantz, Constantine [21st Century Oncology, Fort Meyers, Florida (United States); Rossi, Peter [Emory University, Atlanta, Georgia (United States); DeWeese, Theodore [The Johns Hopkins University, Baltimore, Maryland (United States); and others

    2015-08-01

    Purpose: Perirectal spacing, whereby biomaterials are placed between the prostate and rectum, shows promise in reducing rectal dose during prostate cancer radiation therapy. A prospective multicenter randomized controlled pivotal trial was performed to assess outcomes following absorbable spacer (SpaceOAR system) implantation. Methods and Materials: Overall, 222 patients with clinical stage T1 or T2 prostate cancer underwent computed tomography (CT) and magnetic resonance imaging (MRI) scans for treatment planning, followed with fiducial marker placement, and were randomized to receive spacer injection or no injection (control). Patients received postprocedure CT and MRI planning scans and underwent image guided intensity modulated radiation therapy (79.2 Gy in 1.8-Gy fractions). Spacer safety and impact on rectal irradiation, toxicity, and quality of life were assessed throughout 15 months. Results: Spacer application was rated as “easy” or “very easy” 98.7% of the time, with a 99% hydrogel placement success rate. Perirectal spaces were 12.6 ± 3.9 mm and 1.6 ± 2.0 mm in the spacer and control groups, respectively. There were no device-related adverse events, rectal perforations, serious bleeding, or infections within either group. Pre-to postspacer plans had a significant reduction in mean rectal V70 (12.4% to 3.3%, P<.0001). Overall acute rectal adverse event rates were similar between groups, with fewer spacer patients experiencing rectal pain (P=.02). A significant reduction in late (3-15 months) rectal toxicity severity in the spacer group was observed (P=.04), with a 2.0% and 7.0% late rectal toxicity incidence in the spacer and control groups, respectively. There was no late rectal toxicity greater than grade 1 in the spacer group. At 15 months 11.6% and 21.4% of spacer and control patients, respectively, experienced 10-point declines in bowel quality of life. MRI scans at 12 months verified spacer absorption. Conclusions: Spacer

  8. Separator-spacer for electrochemical systems

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Newby, Kenneth R.; Bellows, Richard J.

    1983-08-02

    An electrochemical cell construction features a novel co-extruded plastic electrode in an interleaved construction with a novel integral separator-spacer. Also featured is a leak and impact resistant construction for preventing the spill of corrosive materials in the event of rupture.

  9. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1980-01-01

    An improved and novel grid spacer for maintaining the fuel rods of a nuclear reactor fuel assembly in substantially parallel array is described. The invention provides for spring strips to maintain the fuel elements in their desired orientation which have more positive alignment than previous types while allowing greater flexibility to counterbalance the effects of differential thermal expansion. (UK)

  10. The utilization of mobile devices for telemedicine services in a South African public healthcare system.

    Science.gov (United States)

    Hartmann, André; Van Dyk, Liezl

    2014-01-01

    The purpose of this study is to develop an understanding in the use of mobile devices in administering telemedicine services within the public health care sector of South Africa. An online questionnaire was developed and distributed amongst medical officers, specialists, students and medical staff of one of the health districts of South Africa. This paper describes the design of the questionnaire as well as the most significant outcomes. Results are presented in terms of reasons why healthcare workers use mobile devices, as well as perceptions in terms of transmission security and quality of transmitted information.

  11. The pyrolytic-plasma method and the device for the utilization of hazardous waste containing organic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Opalińska, Teresa [Tele and Radio Research Institute, Ratuszowa 11, 03-450 Warsaw (Poland); Wnęk, Bartłomiej, E-mail: bartlomiej.wnek@itr.org.pl [Tele and Radio Research Institute, Ratuszowa 11, 03-450 Warsaw (Poland); Witowski, Artur; Juszczuk, Rafał; Majdak, Małgorzata [Tele and Radio Research Institute, Ratuszowa 11, 03-450 Warsaw (Poland); Bartusek, Stanilav [VŠB—Technical University of Ostrava, 17. listopadu 15/2172, 708 33 Ostrava − Poruba Czech Republic (Czech Republic)

    2016-11-15

    Highlights: • A first stage of the process of waste utilization consisted in pyrolysis of waste. • Then the pyrolytic gas was oxidized with a use of non-equilibrium plasma. • The device for the process implementation was built and characterized. • Correctness of the device operation was proven with a use of the decomposition of PE. • Usefulness of the method was proven in the process of utilization of EW. - Abstract: This paper is focused on the new method of waste processing. The waste, including hazardous waste, contain organic compounds. The method consists in two main processes: the pyrolysis of waste and the oxidation of the pyrolytic gas with a use of non-equilibrium plasma. The practical implementation of the method requires the design, construction and testing of the new device in large laboratory scale. The experiments were carried out for the two kinds of waste: polyethylene as a model waste and the electronic waste as a real waste. The process of polyethylene decomposition showed that the operation of the device is correct because 99.74% of carbon moles contained in the PE samples was detected in the gas after the process. Thus, the PE samples practically were pyrolyzed completely to hydrocarbons, which were completely oxidized in the plasma reactor. It turned out that the device is useful for decomposition of the electronic waste. The conditions in the plasma reactor during the oxidation process of the pyrolysis products did not promote the formation of PCDD/Fs despite the presence of the oxidizing conditions. An important parameter determining the efficiency of the oxidation of the pyrolysis products is gas temperature in the plasma reactor.

  12. Pressure Drop Test of Hybrid Mixing Vane Spacer Grid

    Energy Technology Data Exchange (ETDEWEB)

    Oh, D. S.; Chang, S. K.; Kim, B. D.; Chun, S. Y.; Chun, T. H

    2007-08-15

    The pressure loss test has been accomplished in the test section containing 5x5 rod bundle with a length of 2 m including 3 spacer grids. The test has been performed for the 5 kinds of spacer grids to compare the pressure loss characteristics: 1. Plain spacer grid which has the same body of the Hybrid but without vane (Plain), 2. Hybrid Vane spacer grid (Hybrid), 3. Hybrid-SC spacer grid which is constructed with coined, chamfered strip and is fabricated by spot welding, 4. Hybrid-LC spacer grid which is constructed with coined, chamfered strip and is fabricated by line welding along intersection line, 5. Westinghouse spacer grid with split vane (Plus-7). The pressure loss coefficient of the Plain, Hybrid, Hybrid-SC, Hybrid-LC, and Plus-7 spacer grid is 0.93, 1.15, 1.02, 1.04, and 1.08, respectively.

  13. Utilization of YouTube as a Tool to Assess Patient Perception Regarding Implanted Cardiac Devices.

    Science.gov (United States)

    Hayes, Kevin; Mainali, Prajeena; Deshmukh, Abhishek; Pant, Sadip; Badheka, Apurva O; Paydak, Hakan

    2014-07-01

    The outreach of YouTube may have a dramatic role in the widespread dissemination of knowledge on implantable cardioverter devices (ICD). This study was designed to review and analyze the information available on YouTube pertaining to implantable cardiac devices such as implantable cardioverter defibrillators (ICDs) and pacemakers. YouTube was queried for the terms "ICD", "Implantable Cardioverter Defibrillator", and "Pacemaker". The videos were reviewed and categorized as according to content; number of views and "likes" or "dislikes" was recorded by two separate observers. Of the 55 videos reviewed, 18 of the videos were categorized as patient education, 12 were advertisements, 8 were intraoperative videos documenting the device implantation procedures, 7 of the videos were produced to document personal patient experiences, and 4 were categorized as documentation of a public event. 3 were intended to educate health care workers. The remaining 3 were intended to raise public awareness about sudden cardiac death. The videos portraying intraoperative procedures generated the most "likes" or "dislikes" per view. While YouTube provides a logical platform for delivery of health information, the information on this platform is not regulated. Initiative by reputed authorities and posting accurate information in such platform can be a great aid in public education regarding device therapy.

  14. A Human Error Analysis with Physiological Signals during Utilizing Digital Devices

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Hee; Oh, Yeon Ju; Shin, Kwang Hyeon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    The introduction of advanced MCR is accompanied with lots of changes and different forms and features through the virtue of new digital technologies. There are various kinds of digital devices such as flat panel displays, touch screens, and so on. The characteristics of these digital devices give many chances to the interface management, and can be integrated into a compact single workstation in an advanced MCR so that workers can operate the plant with minimum burden during any operating condition. However, these devices may introduce new types of human errors, and thus we need a means to evaluate and prevent such error, especially those related to the digital devices. Human errors have been retrospectively assessed for accident reviews and quantitatively evaluated through HRA for PSA. However, the ergonomic verification and validation is an important process to defend all human error potential in the NPP design. HRA is a crucial part of a PSA, and helps in preparing a countermeasure for design by drawing potential human error items that affect the overall safety of NPPs. Various HRA techniques are available however: they reveal shortages of the HMI design in the digital era. - HRA techniques depend on PSFs: this means that the scope dealing with human factors is previously limited, and thus all attributes of new digital devices may not be considered in HRA. - The data used to HRA are not close to the evaluation items. So, human error analysis is not easy to apply to design by several individual experiments and cases. - The results of HRA are not statistically meaningful because accidents including human errors in NPPs are rare and have been estimated as having an extremely low probability

  15. Hydraulic Design Criteria for Spacer Grids of Nuclear Fuel Element

    International Nuclear Information System (INIS)

    Juanico, Luis; Brasnarof, Daniel

    2000-01-01

    In this paper a hydraulic model for calculating the pressure drop on the CARA spacer grids is extended.This model is validated and feedback from experimental hydraulic test performed in a low pressure loop.The importance of the spacer grid geometric parameter (that is, its thickness and length, the number and kind of their fix spacer), developing hydraulic design criteria for spacer grid on fuel element

  16. Flow behavior of droplets downstream of the spacer

    International Nuclear Information System (INIS)

    Kodama, Eiichiro; Morishita, Kiyohide; Aritomi, Masanori; Yano, Takashi

    1998-01-01

    The fuel spacer, of which role is to maintain an appropriate rod-to-rod clearance, is one of the components of a Boiling Water Reactor (BWR) fuel rod bundles. The fuel spacer influences flow characteristics of the liquid film in fuel rod bundles, so that its geometry influences greatly thermal hydraulics such as critical power and pressure drop therein. The purpose of this study is to clarify the effect of the spacer geometry on the core flow split downstream of the spacer. Phase Doppler Anemometry (PDA) was used for their meausrement under the conditions of a small amount of droplets in mist flows. From the experimental results, the normalized droplet velocity profiles with a spacer were split by the spacer and were different between a wider and a narrower regions in the channel, however, they became uniform at the distance far 100mm from the spacer. In the case without a spacer, the velocity was monotonously increasing nearer the rod surface with going toward the center of the channel. In the case with a spacer, the velocity profile downstream of the spacer changed in the narrower region of the channel. This tendency became more remarkable with thickening the spacer and widening clearance between the spacer and the wall. In this paper, 'drift' velocity effect was applied for the spacer model, due to the gas flows were split by the spacer which is based on the momentum balance between the narrower and wider channels. This model was confirmed from the experimental results that the droplet flowed from a wider region to a narrower one. This drift effect appeared more strongly as the spacer became thicker and the clearance did narrower. The analytical results explained qualitatively the measured ones. It is clarified that the drift effect proposed in this work was a dominant factor on droplet deposition downstream of the spacer

  17. Test device for measuring permeability of a barrier material

    Science.gov (United States)

    Reese, Matthew; Dameron, Arrelaine; Kempe, Michael

    2014-03-04

    A test device for measuring permeability of a barrier material. An exemplary device comprises a test card having a thin-film conductor-pattern formed thereon and an edge seal which seals the test card to the barrier material. Another exemplary embodiment is an electrical calcium test device comprising: a test card an impermeable spacer, an edge seal which seals the test card to the spacer and an edge seal which seals the spacer to the barrier material.

  18. Fabrication of graphene-based flexible devices utilizing a soft lithographic patterning method

    Science.gov (United States)

    Jung, Min Wook; Myung, Sung; Kim, Ki Woong; Song, Wooseok; Jo, You-Young; Lee, Sun Suk; Lim, Jongsun; Park, Chong-Yun; An, Ki-Seok

    2014-07-01

    There has been considerable interest in soft lithographic patterning processing of large scale graphene sheets due to the low cost and simplicity of the patterning process along with the exceptional electrical or physical properties of graphene. These properties include an extremely high carrier mobility and excellent mechanical strength. Recently, a study has reported that single layer graphene grown via chemical vapor deposition (CVD) was patterned and transferred to a target surface by controlling the surface energy of the polydimethylsiloxane (PDMS) stamp. However, applications are limited because of the challenge of CVD-graphene functionalization for devices such as chemical or bio-sensors. In addition, graphene-based layers patterned with a micron scale width on the surface of biocompatible silk fibroin thin films, which are not suitable for conventional CMOS processes such as the patterning or etching of substrates, have yet to be reported. Herein, we developed a soft lithographic patterning process via surface energy modification for advanced graphene-based flexible devices such as transistors or chemical sensors. Using this approach, the surface of a relief-patterned elastomeric stamp was functionalized with hydrophilic dimethylsulfoxide molecules to enhance the surface energy of the stamp and to remove the graphene-based layer from the initial substrate and transfer it to a target surface. As a proof of concept using this soft lithographic patterning technique, we demonstrated a simple and efficient chemical sensor consisting of reduced graphene oxide and a metallic nanoparticle composite. A flexible graphene-based device on a biocompatible silk fibroin substrate, which is attachable to an arbitrary target surface, was also successfully fabricated. Briefly, a soft lithographic patterning process via surface energy modification was developed for advanced graphene-based flexible devices such as transistors or chemical sensors and attachable devices on a

  19. Fabrication of graphene-based flexible devices utilizing a soft lithographic patterning method

    International Nuclear Information System (INIS)

    Wook Jung, Min; Myung, Sung; Woong Kim, Ki; Song, Wooseok; Suk Lee, Sun; Lim, Jongsun; An, Ki-Seok; Jo, You-Young; Park, Chong-Yun

    2014-01-01

    There has been considerable interest in soft lithographic patterning processing of large scale graphene sheets due to the low cost and simplicity of the patterning process along with the exceptional electrical or physical properties of graphene. These properties include an extremely high carrier mobility and excellent mechanical strength. Recently, a study has reported that single layer graphene grown via chemical vapor deposition (CVD) was patterned and transferred to a target surface by controlling the surface energy of the polydimethylsiloxane (PDMS) stamp. However, applications are limited because of the challenge of CVD-graphene functionalization for devices such as chemical or bio-sensors. In addition, graphene-based layers patterned with a micron scale width on the surface of biocompatible silk fibroin thin films, which are not suitable for conventional CMOS processes such as the patterning or etching of substrates, have yet to be reported. Herein, we developed a soft lithographic patterning process via surface energy modification for advanced graphene-based flexible devices such as transistors or chemical sensors. Using this approach, the surface of a relief-patterned elastomeric stamp was functionalized with hydrophilic dimethylsulfoxide molecules to enhance the surface energy of the stamp and to remove the graphene-based layer from the initial substrate and transfer it to a target surface. As a proof of concept using this soft lithographic patterning technique, we demonstrated a simple and efficient chemical sensor consisting of reduced graphene oxide and a metallic nanoparticle composite. A flexible graphene-based device on a biocompatible silk fibroin substrate, which is attachable to an arbitrary target surface, was also successfully fabricated. Briefly, a soft lithographic patterning process via surface energy modification was developed for advanced graphene-based flexible devices such as transistors or chemical sensors and attachable devices on a

  20. Lab-on-a-chip based total-phosphorus analysis device utilizing a photocatalytic reaction

    Science.gov (United States)

    Jung, Dong Geon; Jung, Daewoong; Kong, Seong Ho

    2018-02-01

    A lab-on-a-chip (LOC) device for total phosphorus (TP) analysis was fabricated for water quality monitoring. Many commercially available TP analysis systems used to estimate water quality have good sensitivity and accuracy. However, these systems also have many disadvantages such as bulky size, complex pretreatment processes, and high cost, which limit their application. In particular, conventional TP analysis systems require an indispensable pretreatment step, in which the fluidic analyte is heated to 120 °C for 30 min to release the dissolved phosphate, because many phosphates are soluble in water at a standard temperature and pressure. In addition, this pretreatment process requires elevated pressures of up to 1.1 kg cm-2 in order to prevent the evaporation of the heated analyte. Because of these limiting conditions required by the pretreatment processes used in conventional systems, it is difficult to miniaturize TP analysis systems. In this study, we employed a photocatalytic reaction in the pretreatment process. The reaction was carried out by illuminating a photocatalytic titanium dioxide (TiO2) surface formed in a microfluidic channel with ultraviolet (UV) light. This pretreatment process does not require elevated temperatures and pressures. By applying this simplified, photocatalytic-reaction-based pretreatment process to a TP analysis system, greater degrees of freedom are conferred to the design and fabrication of LOC devices for TP monitoring. The fabricated LOC device presented in this paper was characterized by measuring the TP concentration of an unknown sample, and comparing the results with those measured by a conventional TP analysis system. The TP concentrations of the unknown sample measured by the proposed LOC device and the conventional TP analysis system were 0.018 mgP/25 mL and 0.019 mgP/25 mL, respectively. The experimental results revealed that the proposed LOC device had a performance comparable to the conventional bulky TP analysis

  1. Design, modeling and utilization of thermoelectrical materials and devices in energy systems

    DEFF Research Database (Denmark)

    Chen, Min

    Thermoelectric generators can convert waste heat that abounds in modern societies into electricity in an environmentally-friendly and reliable manner, and many applications of thermoelectric devices can be envisaged. The research of this PhD dissertation focuses thermoelectric generator modeling...... at a device level as well as its applications in energy systems. The purpose is to introduce the use of thermoelectric generator into energy systems, and to indicate the impact of implementing thermoelectric generator on the design and operation of energy systems. For this purpose, this dissertation produces...... numerical models as versatile simulation tools to identify speci c optimum design criteria for thermoelectric generators used in various associated thermal and electrical systems, so that the generation performance can be improved due to the optimum system design....

  2. Radiation transmission type pipe wall thinning detection device and measuring instruments utilizing ionizing radiation

    International Nuclear Information System (INIS)

    Higashi, Yasuhiko

    2009-01-01

    We developed the device to detect thinning of pipe thorough heat insulation in Power Plant, etc, even while the plant is under operation. It is necessary to test many parts of many pipes for pipe wall thinning management, but it is difficult within a limited time of the routine test. This device consists of detector and radiation source, which can detect the pipe (less than 500 mm in external diameter, less than 50 mm in thickness) with 1.6%-reproducibility (in a few-minutes measurement), based on the attenuation rate. Operation is easy and effective without removing the heat insulation. We will expand this thinning detection system, and contribute the safety of the Plant. (author)

  3. Brain Computer Interface-Controlling Devices Utilizing The Alpha Brain Waves

    Directory of Open Access Journals (Sweden)

    Rohan Hundia

    2015-01-01

    Full Text Available Abstract This paper describes the development and testing of an interface system whereby one can control external devices by voluntarily controlling alpha waves that is through eye movement. Such a system may be used for the control of prosthetics robotic arms and external devices like wheelchairs using the alpha brain waves and the Mu rhythm. The response generated through the movement of the eye detecting and controlling the amplitude of the alpha brain waves is interfaced and processed to control Robotic systems and smart home control. In order to measure the response of alpha waves over different lobes of the brain initially I measured these signals over 32 regions using silver chloride plated electrodes. By the opening and the closure of the eyes and the movement in the up-down left-right directions and processing these movements measuring them over the occipital region I was able to differentiate the amplitude of the alpha waves generated due to these several movements. In the First session testing period subjects were asked to close and open their eyes and they were able to control limited movements of a Robot and a prosthetic arm. In the Second 2session the movement of the eyes was also considered left-right up-down along with the opening and closure during this time span they were able to control more dimensions of the robot several devices at the same time using different eye movements.

  4. Utilizing national and international registries to enhance pre-market medical device regulatory evaluation.

    Science.gov (United States)

    Yue, Lilly Q; Campbell, Gregory; Lu, Nelson; Xu, Yunling; Zuckerman, Bram

    2016-01-01

    Regulatory decisions are made based on the assessment of risk and benefit of medical devices at the time of pre-market approval and subsequently, when post-market risk-benefit balance needs reevaluation. Such assessments depend on scientific evidence obtained from pre-market studies, post-approval studies, post-market surveillance studies, patient perspective information, as well as other real world data such as national and international registries. Such registries provide real world evidence and are playing a more and more important role in enhancing the safety and effectiveness evaluation of medical devices. While these registries provide large quantities of data reflecting real world practice and can potentially reduce the cost of clinical trials, challenges arise concerning (1) data quality adequate for regulatory decision-making, (2) bias introduced at every stage and aspect of study, (3) scientific validity of study designs, and (4) reliability and interpretability of study results. This article will discuss related statistical and regulatory challenges and opportunities with examples encountered in medical device regulatory reviews.

  5. Developing a reproducible non-line-of-sight experimental setup for testing wireless medical device coexistence utilizing ZigBee.

    Science.gov (United States)

    LaSorte, Nickolas J; Rajab, Samer A; Refai, Hazem H

    2012-11-01

    The integration of heterogeneous wireless technologies is believed to aid revolutionary healthcare delivery in hospitals and residential care. Wireless medical device coexistence is a growing concern given the ubiquity of wireless technology. In spite of this, a consensus standard that addresses risks associated with wireless heterogeneous networks has not been adopted. This paper serves as a starting point by recommending a practice for assessing the coexistence of a wireless medical device in a non-line-of-sight environment utilizing 802.15.4 in a practical, versatile, and reproducible test setup. This paper provides an extensive survey of other coexistence studies concerning 802.15.4 and 802.11 and reports on the authors' coexistence testing inside and outside an anechoic chamber. Results are compared against a non-line-of-sight test setup. Findings relative to co-channel and adjacent channel interference were consistent with results reported in the literature.

  6. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  7. Single-electron transistors fabricated with sidewall spacer patterning

    Science.gov (United States)

    Park, Byung-Gook; Kim, Dae Hwan; Kim, Kyung Rok; Song, Ki-Whan; Lee, Jong Duk

    2003-09-01

    We have implemented a sidewall spacer patterning method for novel dual-gate single-electron transistor (DGSET) and metal-oxide-semiconductor-based SET (MOSET) based on the uniform SOI wire, using conventional lithography and processing technology. A 30 nm wide silicon quantum wire is defined by a sidewall spacer patterning method, and depletion gates for two tunnel junctions of the DGSET are formed by the doped polycrystalline silicon sidewall. The fabricated DGSET and MOSET show clear single-electron tunneling phenomena at liquid nitrogen temperature and insensitivity of the Coulomb oscillation period to gate bias conditions. On the basis of the phase control capability of the sidewall depletion gates, we have proposed a complementary self-biasing method, which enables the SET/CMOS hybrid multi-valued logic (MVL) to operate perfectly well at high temperature, where the peak-to-valley current ratio of Coulomb oscillation severely decreases. The suggested scheme is evaluated by SPICE simulation with an analytical DGSET model, and it is confirmed that even DGSETs with a large Si island can be utilized efficiently in the multi-valued logic.

  8. Interchangeable opening and closing clapper device notably for ventilation ducts utilizing an aggressive or polluting fluid

    International Nuclear Information System (INIS)

    1980-01-01

    This opening and closing device is of the type which employs a casing inside the duct along the fluid path. It is provided with an opening through which the fluid flows and a joint with a closing clapper controlled from the outside enabling the fluid flow to be regulated. It is characterized by the fact that the casing is provided with a lateral opening with respect to the fluid flow direction, the size of this opening being sufficiently large to allow the assembly with its closing clapper to be introduced and withdrawn [fr

  9. Energy storage devices having anodes containing Mg and electrolytes utilized therein

    Science.gov (United States)

    Shao, Yuyan; Liu, Jun

    2015-08-18

    For a metal anode in a battery, the capacity fade is a significant consideration. In energy storage devices having an anode that includes Mg, the cycling stability can be improved by an electrolyte having a first salt, a second salt, and an organic solvent. Examples of the organic solvent include diglyme, triglyme, tetraglyme, or a combination thereof. The first salt can have a magnesium cation and be substantially soluble in the organic solvent. The second salt can enhance the solubility of the first salt and can have a magnesium cation or a lithium cation. The first salt, the second salt, or both have a BH.sub.4 anion.

  10. Heterogeneous diversity of spacers within CRISPR

    Science.gov (United States)

    Deem, Michael; He, Jiankui

    2011-03-01

    Clustered regularly interspaced short palindromic repeats (CRISPR) in bacterial and archaeal DNA have recently been shown to be a new type of anti-viral immune system in these organisms. We here study the diversity of spacers in CRISPR under selective pressure. We propose a population dynamics model that explains the biological observation that the leader-proximal end of CRISPR is more diversified and the leader-distal end of CRISPR is more conserved. This result is shown to be in agreement with recent experiments. Our results show that the CRISPR spacer structure is influenced by and provides a record of the viral challenges that bacteria face. 1) J. He and M. W. Deem, Phys. Rev. Lett. 105 (2010) 128102

  11. Design and construction of safety devices utilizing methods of measurement and control engineering

    Energy Technology Data Exchange (ETDEWEB)

    Greiner, B; Weidlich, S

    1982-08-01

    This article considers a proposed concept for the design and construction of measurement and control devices for the safety of chemical plants with the aim of preventing danger to persons and the environment and damage. Such measurement and control devices are generally employed when primary measures adopted for plant safety, such as safety valves, collection vessels, etc. are not applicable or insufficient by themselves. The concept regards the new sheet no. 3 of the VDI/VDE code draft 2180 ''Safety of chemical engineering plant'' and proposes a further subdivision of class A into safety classes A0, A1, and A2. Overall, it is possible, on the basis of the measures for raising the availability of measurement and control equipment which are presented in this article, to make selection appropriate to the potential danger involved. The proposed procedure should not, however, be regarded as a rigid scheme but rather as leading to a systematic view and supporting decisions resting on sound operating experience.

  12. Utilization of assistive devices for students with disabilities in the public schools

    Directory of Open Access Journals (Sweden)

    Carolina Bastos Plotegher

    2013-04-01

    Full Text Available Introduction: Assistive technology is an area of expanding knowledge in Brazil. Its use in school can help students with disabilities in performing important tasks to participate in different activities. Objectives: to report the experience of using assistive devices in the academic achievement of students with disabilities included in the regular school system of the municipality of Sao Carlos, state of Sao Paulo. Method: it was developed from an extension project conducted in 2010. Thirteen students with various types of disabilities participated in the project. The interventions were based on the School Function Assessment with the teachers to know the students’ difficulties. The students were also observed performing school tasks. Results: Forty-seven adaptations were made: thickeners, rings for zippers, slants, communication boards, non-slip mats, among others. Besides the adjustments, orientation regarding use of the devices was provided for teachers and persons responsible for the students. Conclusion: we believe that the project benefited the students, because it produced higher academic achievement and provided better school conditions for their school inclusion. For the undergraduate students of Occupational Therapy, the project enabled the dealing with real issues of inclusion and school interventions, thus approaching theory to practice.

  13. Mechanical test for fuel assembly spacer grid

    International Nuclear Information System (INIS)

    Kang, Heung Seok; Jeong, Yeon Ho; Song, Kee Nam; Kim, Hyung Kyu; Yoon, Kyung Ho; Bang, Je Keun.

    1997-06-01

    In order to propose some tests for a new spacer grid, the grid mechanical tests performed by ABB-CE, KWU and Westinghouse have been investigated. It is known that a static compression test, a dynamic impact test, and a grid spring characteristic test were commonly carried out by the vendors when a prototype spacer grid was developed. The static compression test is to measure the stresses on the strips as well as to obtain the grid stiffness. The dynamic impact test is to get some basic data for accident analysis such as impact stiffness, impact strength, and coefficient of restitution. Since each fuel vendor has his theory on an accident analysis, every vendor employs his particular method for the dynamic impact test. The dynamic impact test can be divided into two in accordance with the number of impact face, and the duration of impact pulse. One is an one-sided impact test and the other is an through-gird impact test. The duration of the impact pulse for the former is considerably shorter than the latter. Therefore, the grid can endure much higher load under the one-sided impact condition than under the through-grid impact condition. The grid spring characteristic test is to obtain a force versus deflection curve. This curve is very important in designing the spacer grid to provide fuel rods with a sound supports in core. (author). 18 tabs., 26 figs

  14. Device for district heating with utilization of waste heat from power plants

    International Nuclear Information System (INIS)

    Korek, J.

    1976-01-01

    In order to utilize the waste heat developing in power plants - especially in nuclear power plants - the author suggests to lead the waste heat of the coolers for oil (which the bearings are lubricated with), hydrogen (which serves for the stator rotor-cooling), and the stator cooling water to the circulating district heating water and to arrange these heat exchangers one behind another or parallel to each other in the water circuit of the district heating system. The oil cooler of the engine transformer is also connected with the circulation of the district heating water. The runback water of the district heating network could thus be heated from approx. 40 0 C up to 65 0 C. (UA) [de

  15. Craniospinal versus whole brain irradiation in Medulloblastoma patients, with introduction of utilizing a simple immobilization device

    Directory of Open Access Journals (Sweden)

    Haddad P

    2001-05-01

    Full Text Available Craniospinal irradiation plus posterior fossa boost (CS1 is the standard modality of post-operative treatment of patient with medulloblastoma, but considering the technical difficulties and limited facilities, often whole- brain irradiation plus posterior fossa boost (WBI had been used in our institution until 1991. Tust a retrospective study was undertaken to compare the patients treated by By WBI and CSI for recurrences and disease-free survival (DFS. Files of all medullobalstoma patients treated post-operatively in our department in the 10 – year period of 1986-1996 were reviewed. To obtain the best possible follow- up, a formal inquiry letter was mailed to all patients’ addresses.Total of 72 patients had been treated, with a mean age of 14.7 years and male-to-female ratio of 1.5:1 Thirty –seven patients had been treated by WBI and 35 by CS. A simple wooden device designed and made in our department was used for CSI patients’ set-up and immobilization. Mean radiation dose to posterior fossa was 4, 765 cGy in WBT and 5, 071 cGY in CSI (180-200 cGy fractions. Sixty-two patients (85% came back for follow-up, with 24 recurrences. Only 24% of CSI patients had recurrences, versus 51% in WBI Nearly all Wbi recurrences versus half of the CSI recurrences were spinal. DFS was 39 months in CSI and 26 months in WBI (P<0.001 . in multi-factorial analysis, only the extent of radiation (CSI versus WBI, P<0.001 was statistically significant. Mean age in our patients was higher than what is commonly reported in literature. The immobilization device introduce was a simple and useful accessory to CSI. Considering DFS, CSI in our department was acceptabley comparable to literature results and significantly superior to WBI. With regard to relatively high spinal recurrence rate even in CSI, the importance of suitable spinal cytological and imaging evaluation is again emphasized.

  16. Utilization of an electronic portal imaging device for measurement of dynamic wedge data

    International Nuclear Information System (INIS)

    Elder, Eric S.; Miner, Marc S.; Butker, Elizabeth K.; Sutton, Danny S.; Davis, Lawrence W.

    1996-01-01

    Purpose/Objective: Due to the motion of the collimator during dynamic wedge treatments, the conventional method of collecting comprehensive wedge data with a water tank and a scanning ionization chamber is obsolete. It is the objective of this work to demonstrate the use of an electronic portal imaging device (EPID) and software to accomplish this task. Materials and Methods: A Varian Clinac[reg] 2300 C/D, equipped with a PortalVision TM EPID and Dosimetry Research Mode experimental software, was used to produce the radiation field. The Dosimetry Research Mode experimental software allows for a band of 10 of 256 high voltage electrodes to be continuously read and averaged by the 256 electrometer electrodes. The file that is produced contains data relating to the integrated ionization at each of the 256 points, essentially the cross plane beam profile. Software was developed using Microsoft C ++ to reformat the data for import into a Microsoft Excel spreadsheet allowing for easy mathematical manipulation and graphical display. Beam profiles were measured by the EPID with a 100 cm TSD for various field sizes. Each field size was measured open, steel wedged, and dynamically wedged. Scanning ionization chamber measurements performed in a water tank were compared to the open and steel wedged fields. Ionization chamber measurements taken in a water tank were compared with the dynamically wedged measurements. For the EPID measurements the depth was varied using Gammex RMI Solid Water TM placed directly above the EPID sensitive volume. Bolus material was placed between the Solid Water TM and the EPID to avoid an air gap. Results: Comparison of EPID measurements with those from an ion chamber in a water tank showed a discrepancy of ∼5%. Scans were successfully obtained for open, steel wedged and dynamically wedged beams. Software has been developed to allow for easy graphical display of beam profiles. Conclusions: Measurement of dynamic wedge data proves to be easily

  17. Fouling resilient perforated feed spacers for membrane filtration.

    Science.gov (United States)

    Kerdi, Sarah; Qamar, Adnan; Vrouwenvelder, Johannes S; Ghaffour, Noreddine

    2018-04-24

    The improvement of feed spacers with optimal geometry remains a key challenge for spiral-wound membrane systems in water treatment due to their impact on the hydrodynamic performance and fouling development. In this work, novel spacer designs are proposed by intrinsically modifying cylindrical filaments through perforations. Three symmetric perforated spacers (1-Hole, 2-Hole, and 3-Hole) were in-house 3D-printed and experimentally evaluated in terms of permeate flux, feed channel pressure drop and membrane fouling. Spacer performance is characterized and compared with standard no perforated (0-Hole) design under constant feed pressure and constant feed flow rate. Perforations in the spacer filaments resulted in significantly lowering the net pressure drop across the spacer filled channel. The 3-Hole spacer was found to have the lowest pressure drop (50%-61%) compared to 0-Hole spacer for various average flow velocities. Regarding permeate flux production, the 0-Hole spacer produced 5.7 L m -2 .h -1 and 6.6 L m -2 .h -1 steady state flux for constant pressure and constant feed flow rate, respectively. The 1-Hole spacer was found to be the most efficient among the perforated spacers with 75% and 23% increase in permeate production at constant pressure and constant feed flow, respectively. Furthermore, membrane surface of 1-Hole spacer was found to be cleanest in terms of fouling, contributing to maintain higher permeate flux production. Hydrodynamic understanding of these perforated spacers is also quantified by performing Direct Numerical Simulation (DNS). The performance enhancement of these perforated spacers is attributed to the formation of micro-jets in the spacer cell that aided in producing enough unsteadiness/turbulence to clean the membrane surface and mitigate fouling phenomena. In the case of 1-Hole spacer, the unsteadiness intensity at the outlet of micro-jets and the shear stress fluctuations created inside the cells are higher than those

  18. Process and device integration for silicon tunnel FETs utilizing isoelectronic trap technology to enhance the ON current

    Science.gov (United States)

    Mori, Takahiro; Asai, Hidehiro; Fukuda, Koichi; Matsukawa, Takashi

    2018-04-01

    A tunnel FET (TFET) is a candidate replacement for conventional MOSFETs to realize low-power LSI. The most significant issue with the practical application of TFETs concerns their low tunneling current. Si is an indirect-gap material with a low band-to-band tunneling probability and is not favored for the channel. However, a new technology has recently been proposed to enhance the tunneling current in Si-TFETs by utilizing isoelectronic trap (IET) technology. IET technology provides an innovative approach to realizing low-power LSI with TFETs. In this paper, state-of-the-art research on Si-TFETs with IET technology from the viewpoint of process and device integration is reviewed.

  19. Nuclear reactor fuel assembly spacer grid

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1977-01-01

    A spacer grid for a nuclear fuel assembly is comprised of a lattice of grid plates forming multiple cells that are penetrated by fuel elements. Resilient protrusions and rigid protrusions projecting into the cells from the plates bear against the fuel element to effect proper support and spacing. Pairs of intersecting grid plates, disposed in a longitudinally spaced relationship, cooperate with other plates to form a lattice wherein each cell contains adjacent panels having resilient protrusions arranged opposite adjacent panels having rigid protrusions. The peripheral band bounding the lattice is provided solely with rigid protrusions projecting into the peripheral cells. (Auth.)

  20. Enhanced current-perpendicular-to-plane giant magnetoresistance effect in half-metallic NiMnSb based nanojunctions with multiple Ag spacers

    Energy Technology Data Exchange (ETDEWEB)

    Wen, Zhenchao; Yamamoto, Tatsuya [Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan); Kubota, Takahide; Takanashi, Koki [Institute for Materials Research, Tohoku University, Sendai 980-8577 (Japan); Center for Spintronics Research Network (CSRN), Tohoku University, Sendai 980-8577 (Japan)

    2016-06-06

    Current-perpendicular-to-plane giant magnetoresistance (CPP-GMR) heterostructure devices using half-metallic NiMnSb Heusler alloy electrodes with single, dual, and triple Ag spacers were fabricated. The NiMnSb alloy films and Ag spacers show (001) epitaxial growth in all CPP-GMR multilayer structures. The dual-spacer CPP-GMR nanojunction exhibited an enhanced CPP-GMR ratio of 11% (a change in the resistance-area product, ΔRA, of 3.9 mΩ μm{sup 2}) at room temperature, which is approximately twice (thrice) of 6% (1.3 mΩ μm{sup 2}) in the single-spacer device. The enhancement of the CPP-GMR effects in the dual-spacer devices could be attributed to improved interfacial spin asymmetry. Moreover, it was observed that the CPP-GMR ratios increased monotonically as the temperatures decreased. At 4.2 K, a CPP-GMR ratio of 41% (ΔRA = 10.5 mΩ μm{sup 2}) was achieved in the dual-spacer CPP-GMR device. This work indicates that multispacer structures provide an efficient enhancement of CPP-GMR effects in half-metallic material-based CPP-GMR systems.

  1. Safety, efficacy, and usage compliance of home-use device utilizing RF and light energies for treating periorbital wrinkles.

    Science.gov (United States)

    Gold, Michael H; Biron, Julie; Levi, Liora; Sensing, Whitney

    2017-03-01

    The aging process is often associated with undesirable effects on facial skin such as skin redundancy, reduction of elasticity, and increased wrinkling. Radiofrequency (RF) and light-emitting diodes (LEDs) are widely used, clinically proven technologies for skin rejuvenation. This study aimed to evaluate the safety, efficacy, and usage compliance of the home-use device, utilizing RF and LED energies, for self-treatment of periorbital wrinkles and improvement of skin appearance. Thirty-three subjects performed 21 treatment sessions every other day, over 6 weeks on the periorbital areas. In addition, two maintenance treatments were conducted 1 and 2 months following treatment end. Each subject served as his/her own control, comparing results before treatment, and 3 months following treatment end. Thirty subjects completed the study. A blinded, independent photographs assessment of three dermatologists demonstrated an average reduction of 1.49 Fitzpatrick scores (P Skin Tightening (HST) device offers a safe and effective in-home noninvasive technique to improve the appearance of age-related periorbital wrinkles. © 2016 Wiley Periodicals, Inc.

  2. Utility of electronic hand hygiene counting devices for measuring physicians' hand hygiene adherence applied to outpatient settings.

    Science.gov (United States)

    Arai, Akie; Tanabe, Masaki; Nakamura, Akiko; Yamasaki, Daisuke; Muraki, Yuichi; Kaneko, Toshihiro; Kadowaki, Ayako; Ito, Masaaki

    2016-12-01

    Our objectives were to evaluate the utility of electronic hand hygiene counting devices in outpatient settings and the impact of results feedback on physicians' hand hygiene behaviors. We installed 130 electronic hand hygiene counting devices in our redesigned outpatient department. We remotely monitored physicians' hand hygiene practices during outpatient examinations and calculated the adherence rate as follows: number of hand hygiene counts divided by the number of outpatients examined multiplied by 100. Physician individual adherence rates were also classified into 4 categories. Two hundred and eighty physicians from 28 clinical departments were monitored for 3 months. The overall hand hygiene adherence rate was 10.7% at baseline, which improved significantly after feedback to 18.2% in the third month. Of the clinical departments, 78.6% demonstrated significant improvement in hand hygiene compliance. The change in the percentage of physicians in each category before and after feedback were as follows: very low (84.3% to 72.1%), low (8.6% to 14.3%), moderate (2.9% to 8.9%), and high (4.3% to 4.6%), from the first to third month, respectively. Based on category assessment, 17.1% of physicians were classified as responders. Physicians' adherence to hand hygiene practices during outpatient examinations was successfully monitored remotely using electronic counting devices. Audit and feedback of adherence data may have a positive impact on physicians' hand hygiene compliance. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  3. White organic light-emitting devices with tunable color emission fabricated utilizing exciplex formation at heterointerfaces including m-MDATA

    International Nuclear Information System (INIS)

    Lee, Kwang Seop; Choo, Dong Chul; Kim, Tae Whan

    2011-01-01

    The electrical and the optical properties of organic light-emitting devices (OLEDs) fabricated utilizing a 4,4',4''-tris(2-methylphenyl-phenylamino)triphenylamine (m-MTDATA) were investigated to clarify the effect of exciplex on their color stabilization and color purity. The electrons combined with the holes at heterointerfaces between the m-MTDATA layer and the 9,10-di(2-naphthyl)anthracene (MADN) and the 4-(dicyanomethylene)-2-methyl-6-(p-dimethyl aminostyryl)-4H-pyran (DCM1) emitting layer (EML) resulted in the formation of the exciplex. The emission peak of the electroluminescence spectra for the OLEDs fabricated utilizing the m-MTDATA layer shifted to a lower energy side in comparison with that of the EML. This was due to the interaction of the holes in the m-MTDATA layer and the electrons in the MADN EML. Carriers in white OLEDs (WOLEDs) with exciplex emissions existed at the heterointerfaces between the m-MTDATA and the EML because the DCM1 EML was too thin to affect the EL peak related to the m-MTDATA layer. The Commission Internationale de l'Eclairage coordinates of WOLEDs at 9.5 V were (0.33, 0.36), and their maximum current efficiency at 46 mA/cm 2 was 2.03 cd/A.

  4. White organic light-emitting devices with tunable color emission fabricated utilizing exciplex formation at heterointerfaces including m-MDATA

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang Seop; Choo, Dong Chul; Kim, Tae Whan, E-mail: twk@hanyang.ac.kr

    2011-05-31

    The electrical and the optical properties of organic light-emitting devices (OLEDs) fabricated utilizing a 4,4',4''-tris(2-methylphenyl-phenylamino)triphenylamine (m-MTDATA) were investigated to clarify the effect of exciplex on their color stabilization and color purity. The electrons combined with the holes at heterointerfaces between the m-MTDATA layer and the 9,10-di(2-naphthyl)anthracene (MADN) and the 4-(dicyanomethylene)-2-methyl-6-(p-dimethyl aminostyryl)-4H-pyran (DCM1) emitting layer (EML) resulted in the formation of the exciplex. The emission peak of the electroluminescence spectra for the OLEDs fabricated utilizing the m-MTDATA layer shifted to a lower energy side in comparison with that of the EML. This was due to the interaction of the holes in the m-MTDATA layer and the electrons in the MADN EML. Carriers in white OLEDs (WOLEDs) with exciplex emissions existed at the heterointerfaces between the m-MTDATA and the EML because the DCM1 EML was too thin to affect the EL peak related to the m-MTDATA layer. The Commission Internationale de l'Eclairage coordinates of WOLEDs at 9.5 V were (0.33, 0.36), and their maximum current efficiency at 46 mA/cm{sup 2} was 2.03 cd/A.

  5. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1978-01-01

    A bimetallic grid spacer is described comprising a grid structure of zircaloy formed by intersecting striplike members which define fuel element openings for receiving fuel elements and spring strips made of Inconel positioned within the grid structure for cooperating with the fuel elements to maintain them in their desired position. A plurality of these spring strips extend longitudinally between sides of the grid structure, being locked in position by the grid retaining strips. The fuel rods, which are disposed in the fuel openings formed in the grid structure, are positioned by means of the springs associated with the spring strips and a plurality of dimples which extend from the zircaloy grid structure into the openings. In one embodiment the strips are disposed in a plurality of arrays with those spring strip arrays situated in opposing diagonal quadrants of the grid structure extending in the same direction and adjacent spring strip arrays in each half of the spacer extending in relatively perpendicular directions. Other variations of the spring strip arrangements for a particular fuel design are disclosed herein

  6. Spacers for use in nuclear fuel assembly

    International Nuclear Information System (INIS)

    Shiohata, Hironori; Nakamura, Shozo; Hasegawa, Kunio; Higuchi, Shigeo; Nagashima, Hideaki; Kawada, Yoshishige.

    1987-01-01

    Purpose: To prevent liquid film breakage at the surface of a fuel rod due to swirlings of steam flow generated at the upstream of a contact portion between the fuel rod and a spacer leaf spring, that is, below the contact portion. Constitution: Steam-hot water 2-phase streams flowing from the lower to the upper portions of a fuel assembly is hindered by leaf springs, thereby forming swirlings in the steam flow at the upstream of a contact portion between the fuel rod and the leaf springs, that is, below the contact portion. The horseshoe-like swirlings shed the liquid films at the surface of the fuel rod to remarkably decrease the heat cooling performance, by which the surface temperature of a fuel can is temporarily increased thereby possibly causing failures due to so-called burnout in view of the above, steps are formed to the spacer leaf spring for use in the fuel assembly, to reduce the pressure difference between the leaf spring and the fuel rod at the upstream of the springs relative to the 2-phase coolant stream. In this way, formation of the swirlings is moderated to prevent the liquid film breakage and improve the critical heat power. (Kamimura, M.)

  7. Development of structural technology for a high performance spacer grid

    International Nuclear Information System (INIS)

    Song, Kee Nam; Kim, H. K.; Kang, H. S.

    2003-03-01

    A spacer grid in a LWR fuel assembly is a key structural component to support fuel rods and to enhance the heat transfer from the fuel rod to the coolant. In this research, the main research items are the development of inherent and high performance spacer grid shapes, the establishment of mechanical/structural analysis and test technology, and the set-up of basic test facilities for the spacer grid. The main research areas and results are as follows. 1. 14 different spacer grid candidates have been invented and applied for domestic and US patents. Among the candidates six are chosen from the patent. 2. Two kinds of spacer grids are finally selected for the advanced LWR fuel after detailed performance tests on the candidates and commercial spacer grids from a mechanical/structural point of view. According to the test results the features of the selected spacer grids are better than those of the commercial spacer grids. 3. Four kinds of basic test facilities are set up and the relevant test technologies are established. 4. Mechanical/structural analysis models and technology for spacer grid performance are developed and the analysis results are compared with the test results to enhance the reliability of the models

  8. Pressure Drop of Chamfer on Spacer Grid Strap

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Euijae; Kim, Kanghoon; Kim, Kyounghong; Nahm, Keeyil [KEPCO Nuclear Fuel Co., Daejeon (Korea, Republic of)

    2014-05-15

    A swirl flow and cross flow are generated by the spacer grid with mixing vane that enhances the thermal performance and critical heat flux (CHF). The additional pressure drop makes it difficult to meet acceptance criteria for overall pressure drop in fuel assembly depending upon the pump capacity. The chamfer on the end of spacer grid strap is one solution to reduce additional pressure drop without any adverse effect on flow fields. In this research, the pressure drop tests for spacer grid with and without chamfer were carried out at the hydraulic test facility. The result can be applied to develop high performance nuclear fuel assemblies for Pressurized Water Reactor (PWR) plants. The pressure drop tests for 5x5 spacer grid with and without chamfer as well as 6x6 spacer grid with and without chamfer were carried out at the INFINIT test facility. The Reynolds number ranged about from 16000 to 75000. The sweep-up and sweep-down test showed that the direction of sweep did not affect the pressure drop. The chamfer on spacer grid strap reduced the pressure drop due to the decreased in ratio of inlet area to outlet area. The pressure loss coefficient for spacer grid with chamfer was by up to 13.8 % lower than that for spacer grid without chamfer. Hence, the chamfer on spacer grid strap was one of effective ways to reduce the pressure drop.

  9. Knowledge and utilization of contraceptive devices among unmarried undergraduate students of a tertiary institution in Kano State, Nigeria 2016.

    Science.gov (United States)

    Ahmed, Zainab Datti; Sule, Ibrahim Baffa; Abolaji, Mohammed Lukman; Mohammed, Yahaya; Nguku, Patrick

    2017-01-01

    Students in the universities mostly live independently from their parents or guardians, some of them for the first time. This gives them freedom and opportunity for high risk behavior such as unplanned and unprotected sex. The results of such sexual experimentation may include unplanned and or unwanted pregnancies that may lead to unsafe abortions and sexually transmitted infections (STIs) including HIV/AIDS. Contraception has the potential to prevent unwanted pregnancies, abortion, and STIs. This study aimed at assessing the general knowledge on contraceptives, sexual practices, and level of utilization of contraceptives devices among unmarried students of the Bayero University Kano. We did an institutional based cross-sectional descriptive study. We administered a pretested, self-administered, structured questionnaire to randomly selected unmarried undergraduate students of the institution. We analyzed data using Microsoft Excel 2016 and Epi-info7. A total of 300 students were interviewed. The median age for respondents was 23 years with an age range of 16-25 years. Male respondents made up 61.3% (184) while the females made up the remaining 38.7% (116). Also, 158(47.33%) of respondents lived outside the school campus, while 158(52.67%) lived in the school hostels. Knowledge on contraception was 87.7% among respondents with internet (91%) and media (89.3%) as the commonest sources of knowledge. Proportion of sexually active students was 10.67%, while prevalence of contraceptive utilization among sexually active students was 15.63%. About 8(25%) had their sexual debut at knowledge on contraceptive used was high among the respondents, utilization of contraceptives among sexually active students was low, thus creating a window for possible unintended and unwanted pregnancies among these group of students.

  10. Enhancement of nuclear heat transfer in a typical pressurized water reactor by new spacer grids

    International Nuclear Information System (INIS)

    Nazifi, M.; Nematollahi, M.

    2007-01-01

    The fuel element geometry typically used in nuclear reactor is rod bundle whose rod-to-rod clearance is maintained by grid spacer. The heat generated in the rod by nuclear reaction is removed by coolant, usually in turbulent flow. The coolant moves axially through the subchannels. Fuel spacer grid affects the coolant flow distribution in a fuel rod bundle, and so spacer geometry has a strong influence on a bundle's thermal-hydraulic characteristics such as critical heat flux and pressure drop. An understanding of the detailed structure of the turbulent flow and heat transfer in the rod bundle, used especially as nuclear fuel elements, is of major interest to the nuclear power industry for their safe and reliable operation. The flow mixing devices on grid spacer would enhance the mixing rate between sub-channels and promote the turbulence in subchannel. The present study evaluates the effects of mixing vane shape on flow structure and heat transfer downstream of mixing vane in a sub-channel of fuel assembly, by obtaining velocity and pressure fields, turbulent intensity, flow mixing factors, heat transfer coefficient and friction factor using three-dimensional RANS analysis. Six new shapes mixing vane designed by the authors, are simulated numerically to evaluate the performance in enhancing the heat transfer, in comparison with commercialized split vane. Standard K-epsilon model are used as a turbulence closure model and periodic and symmetry condition are set as boundary conditions. The capability of the model to predict the coolant flow distribution inside rod bundles is shown and discussed on the base of comparison with experimental data for a variety of geometrical and Reynolds number conditions. It is conformed that the turbulence in the sub-channel was significantly promoted by spacer and mixing devices but rapidly decreased to a fully developed level approximately 10 time of hydraulic diameter downstream of the top of spacer. Ring type mixer showed a high

  11. Finite element analysis of the contact between fuel rod and spacer grid

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kyu; Kim, Young Koon; Kang, Heung Seok; Yoon, Kyung Ho; Song, Kee Nam [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-01-01

    For the research on the fretting failure problem of nuclear fuel, the contact length and normal stress field are evaluated for the contact between fuel rod and spacer grid by using the Finite Element Method (FEM). An assumption of semi-infiniteness is necessary for applying the Contact Mechanics which is based on the classical theory of elasticity to the present problem. For the contact problem of fuel fretting, the contact mechanical solutions could be utilized well with sufficient accuracy if the contact bodies (i.e., the cladding tube and the spacer grid) can be assumed as semi-infinite bodies. To this end, the contact length evaluated by FEM is discussed together with the relevant research which concerned the effect of dimension for the validity of the assumption of semi-infiniteness. Normal stress profile on the contact is also studied through comparing the theoretical and the FE results. For the analysis of contact problem by FEM, ANSYS code (Version 5.3) is utilized and the geometry is chosen to be the Hertzian (cylinder-to-cylinder), the strip-to-cylinder and the fuel rod/spacer grid contact (strip-to-tube). Present research will be utilized for accessing the fuel fretting problem by FEM together with the theoretical (i.e., contact mechanical) analysis which has been published as KAERI/TR-1113/98. (author). 15 refs., 44 figs., 4 tabs.

  12. Efficient thermal diode with ballistic spacer

    Science.gov (United States)

    Chen, Shunda; Donadio, Davide; Benenti, Giuliano; Casati, Giulio

    2018-03-01

    Thermal rectification is of importance not only for fundamental physics, but also for potential applications in thermal manipulations and thermal management. However, thermal rectification effect usually decays rapidly with system size. Here, we show that a mass-graded system, with two diffusive leads separated by a ballistic spacer, can exhibit large thermal rectification effect, with the rectification factor independent of system size. The underlying mechanism is explained in terms of the effective size-independent thermal gradient and the match or mismatch of the phonon bands. We also show the robustness of the thermal diode upon variation of the model's parameters. Our finding suggests a promising way for designing realistic efficient thermal diodes.

  13. Nuclear reactor spring strip grid spacer

    International Nuclear Information System (INIS)

    Patterson, J.F.; Flora, B.S.

    1980-01-01

    An improved and novel grid spacer was developed for use in nuclear reactor fuel assemblies. It is comprised of a series of intersecting support strips and a peripheral support band attached to the ends of the support strips. Each of the openings into which the fuel element is inserted has a number of protruding dimples and springs extending in different directions. The dimples coact with the springs to secure the fuel rods in the openings. Compared with previous designs, this design gives more positive alignment of the support stips while allowing greater flexibility to counterbalance the effects of thermal expansion. The springs are arranged in alternating directions so that the reaction forces tend to counterbalance each other, which in turn minimizes the reaction loads on the supporting structure. (D.N.)

  14. PCR-Internal Transcribed Spacer (ITS) genes sequencing and ...

    African Journals Online (AJOL)

    Methods: DNA extraction, purification, amplification and sequencing of Internal Transcribed Spacer (ITS) genes were per- formed using ... Keywords: Internal transcribed spacer genes, phylogenetic, genetic relationship, clinical and environmental fungi, HIV-TB. ... Nigeria. An Ethical clearance was obtained from the Eth-.

  15. Stress Analysis of Single Spacer Grid Support considering Fuel Rod

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Y. G.; Jung, D. H.; Kim, J. H. [Chungnam National University, Daejeon (Korea, Republic of); Park, J. K.; Jeon, K. L. [Korea Nuclear Fuel, Daejeon (Korea, Republic of)

    2010-10-15

    Pressurized water reactor (PWR) nuclear fuel assembly is mainly composed of a top-end piece, a bottom-end piece, lots of fuel rods, and several spacer grids. Among them, the main function of spacer grid is protecting fuel rods from Fluid Induced Vibration (FIV). The cross section of spacer grid assembled by laser welding in upper and lower point. When the fuel rod inserted in spacer gird, spring and dimple and around of welded area got a stresses. The main hypothesis of this analysis is the boundary area of HAZ and base metal can get a lot of damage than other area by FIV. So, design factors of spacer grid mainly considered to preventing the fatigue failure in HAZ and spring and dimple of spacer grid. From previous researching, the environment in reactor verified. Pressure and temperature of light water observed 15MPa and 320 .deg. C, and vibration of the fuel rod observed within 0 {approx} 50Hz. In this study, mechanical properties of zirconium alloy that extracted from the test and the spacer grid model which used in the PWR were applied in stress analyzing. General-purpose finite element analysis program was used ANSYS Workbench 12.0.1 version. 3-D CAD program CATIA was used to create spacer grid model

  16. Mechanical/structural performance test method of a spacer grid

    International Nuclear Information System (INIS)

    Yoon, Kyung Ho

    2000-06-01

    The spacer grid is one of the main structural components in the fuel assembly, which supports the fuel rods, guides cooling water, and protects the system from an external impact load, such as earthquakes. In order to develop the spacer grid with the high mechanical performance, the mechanical and structural properties of the spacer grids must be extensively examined while designing it. In this report, the mechanical/structural test methods, i.e. the characteristic test of a spacer grid spring or dimple, static buckling test of a partial or full size spacer grid and dynamic impact test of them are described. The characteristic test of a spacer grid spring or dimple is accomplished with universal tensile test machine, a specimen is fixed with test fixture and then applied compressive load. The characteristic test data is saved at loading and unloading event. The static buckling test of a partial or full size spacer grid is executed with the same universal tensile testing machine, a specimen is fixed between cross-heads and then applied the compressive load. The buckling strength is decided the maximum strength at load vs. displacement curve. The dynamic impact test of a partial or full size spacer grid is performed with pendulum type impact machine and free fall shock test machine, a specimen is fixed with test fixture and then applied the impact load by impact hammer. Specially, the pendulum type impact test machine is also possible under the operating temperature because a furnace is separately attached with test machine

  17. ATLAS barrel hadron tile calorimeter: spacers plates mass production

    International Nuclear Information System (INIS)

    Artikov, A.M.; Budagov, Yu.A.; Khubua, J.

    1999-01-01

    In this article we expose the main problems of the mass production of the so-called 'spacer plates' for the ATLAS Barrel Hadron Tile Calorimeter. We describe all practical solutions of these problems. Particularly we present the measurement procedures and calculation schemes we used for the spacers dimensions determination. The results of the calculations are presented

  18. A non-electrostatic spacer for aerosol delivery

    DEFF Research Database (Denmark)

    Bisgaard, H; Anhøj, J; Klug, B

    1995-01-01

    to 6 years, suspected to have asthma the non-electrostatic spacer delivered a mean total dose of budesonide aerosol of 39% of the nominal dose, which was significantly higher than the Babyhaler (28%), the Nebuhaler (21%), and the AeroChamber (19%). These differences were most pronounced in children......A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide...... was 27 seconds and independent of the use of p-MDI. In vitro the maximum dose of budesonide from a p-MDI, expressed as a percentage of the nominal dose, was 56% from the non-electrostatic spacer, 61% from the Nebuhaler, 45% from the Babyhaler, and 30% from the AeroChamber. In 124 children, age 6 months...

  19. Invariance of the magnetic behavior and AMI in ferromagnetic biphase films with distinct non-magnetic metallic spacers

    Energy Technology Data Exchange (ETDEWEB)

    Silva, E.F. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Gamino, M. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Andrade, A.M.H. de [Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Vázquez, M. [Instituto de Ciencia de Materiales de Madrid, CSIC, 28049 Madrid (Spain); Correa, M.A. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Bohn, F., E-mail: felipebohn@fisica.ufrn.br [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil)

    2017-02-01

    We investigate the quasi-static magnetic, magnetotransport, and dynamic magnetic properties in ferromagnetic biphase films with distinct non-magnetic metallic spacer layers. We observe that the nature of the non-magnetic metallic spacer material does not have significant influence on the overall biphase magnetic behavior, and, consequently, on the magnetotransport and dynamic magnetic responses. We focus on the magnetoimpedance effect and verify that the films present asymmetric magnetoimpedance effect. Moreover, we explore the possibility of tuning the linear region of the magnetoimpedance curves around zero magnetic field by varying the probe current frequency in order to achieve higher sensitivity values. The invariance of the magnetic behavior and the asymmetric magnetoimpedance effect in ferromagnetic biphase films with distinct non-magnetic metallic spacers place them as promising candidates for probe element and open possibilities to the development of lower-cost high sensitivity linear magnetic field sensor devices.

  20. Effects of different rod spacers (helical types) on coolant crossmixing

    International Nuclear Information System (INIS)

    Zhukov, A.V.; Sviridenko, E.Ya.; Matyukhin, N.M.; Rymkevich, K.S.; Ushakov, P.A.

    1981-11-01

    The results of investigations (electromagnetic measuring method) on coolant cross mixing in rod clusters with spiral wire spacers with different winding directions, with alternating unfinned and finned rods (case 'fin to rod'), as well as in rod clusters with much space between the rods, (case 'fin to fin') are reported. The local fluid dynamics parameters (distribution of the transversal and longitudinal velocity component) that define the physical processes of the coolant exchange in the rod clusters with helical spacers are explained. The investigation results for different helical spacer types are compared with each other. (orig.) [de

  1. Grid spacers for use in a nuclear fuel assembly

    International Nuclear Information System (INIS)

    Kuwako, Akira.

    1987-01-01

    Purpose: To obtain spacers capable of reducing the pressure loss by enlarging coolant flow channels when the fuel temperature is high, while capable of reliably maintaining the fuel pins with no vibrations when the fuel temperature is low. Constitution: This invention concerns grid spacers for constituting fuel assemblies for use in water cooled reactors. Memory shape alloys are disposed at least a portion of a spacer element that takes such a shape as urging the pin when the fuel temperature is low, while enlarging the coolant flow channel to reduce the pressure loss when the fuel temperature is high. (Ikeda, J.)

  2. Preclinical Evaluation of Bioabsorbable Polyglycolic Acid Spacer for Particle Therapy

    International Nuclear Information System (INIS)

    Akasaka, Hiroaki; Sasaki, Ryohei; Miyawaki, Daisuke; Mukumoto, Naritoshi; Sulaiman, Nor Shazrina Binti; Nagata, Masaaki; Yamada, Shigeru; Murakami, Masao; Demizu, Yusuke; Fukumoto, Takumi

    2014-01-01

    Purpose: To evaluate the efficacy and safety of a polyglycolic acid (PGA) spacer through physical and animal experiments. Methods and Materials: The spacer was produced with surgical suture material made of PGA, forming a 3-dimensional nonwoven fabric. For evaluation or physical experiments, 150-MeV proton or 320-MeV carbon-ion beams were used to generate 60-mm width of spread-out Bragg peak. For animal experiments, the abdomens of C57BL/6 mice, with or without the inserted PGA spacers, were irradiated with 20 Gy of carbon-ion beam (290 MeV) using the spread-out Bragg peak. Body weight changes over time were scored, and radiation damage to the intestine was investigated using hematoxylin and eosin stain. Blood samples were also evaluated 24 days after the irradiation. Long-term thickness retention and safety were evaluated using crab-eating macaques. Results: No chemical or structural changes after 100 Gy of proton or carbon-ion irradiation were observed in the PGA spacer. Water equivalency of the PGA spacer was equal to the water thickness under wet condition. During 24 days' observation after 20 Gy of carbon-ion irradiation, the body weights of mice with the PGA spacer were relatively unchanged, whereas significant weight loss was observed in those mice without the PGA spacer (P<.05). In mice with the PGA spacer, villus and crypt structure were preserved after irradiation. No inflammatory reactions or liver or renal dysfunctions due to placement of the PGA spacer were observed. In the abdomen of crab-eating macaques, thickness of the PGA spacer was maintained 8 weeks after placement. Conclusions: The absorbable PGA spacer had water-equivalent, bio-compatible, and thickness-retaining properties. Although further evaluation is warranted in a clinical setting, the PGA spacer may be effective to stop proton or carbon-ion beams and to separate normal tissues from the radiation field

  3. Analysis of US patents on spacer grids

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu; Song, Kee Nam; Yoon, Kyung Ho; Kang, Hong Seok; Kim, Hyung Kyu; Jeon, Tae Hyun; Oh, Dong Seok; In, Wang Ki; Bang, Jae Keun; Oh, Seung Eun; Seo, Jeong Min; Lee, Jin Seok; Park, Seong Keun

    1997-06-01

    The total of 137 US patents on spacer grids patented from 1968 through 1993 are analyzed and summarized. Database is constituted with designing the appropriate fields by which each patent can be identified. The fields consist of patent number, inventor, assignee, date of patent, title and major foci of the patent. The major foci are again classified by detailed subjects such as the fretting failure and fuel rod support-related, the strength-related, the fabrication-related as for mechanical subjects, while the cooling performance-related and the pressure drop-related as for thermal-hydraulic one. The 92% of the patents analyzed were issued form nuclear companies of USA, France and Germany. Among the patents dealing with mechanical subjects, the fretting failure and fuel rod support-related is more than the pressure drop-related among the patents of thermal-hydraulic subjects. The number of patents issued from Japan ranks just after Germany i.e., the 4th country. It is thought that much concern as well as investment should be increased in this field, the patent of nuclear components. (author). 2 tabs., 5 figs

  4. Analysis of US patents on spacer grids

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kyu; Song, Kee Nam; Yoon, Kyung Ho; Kang, Hong Seok; Kim, Hyung Kyu; Jeon, Tae Hyun; Oh, Dong Seok; In, Wang Ki; Bang, Jae Keun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); Oh, Seung Eun; Seo, Jeong Min; Lee, Jin Seok; Park, Seong Keun [Korea Nuclear Fuel Company, Taejon (Korea, Republic of)

    1997-06-01

    The total of 137 US patents on spacer grids patented from 1968 through 1993 are analyzed and summarized. Database is constituted with designing the appropriate fields by which each patent can be identified. The fields consist of patent number, inventor, assignee, date of patent, title and major foci of the patent. The major foci are again classified by detailed subjects such as the fretting failure and fuel rod support-related, the strength-related, the fabrication-related as for mechanical subjects, while the cooling performance-related and the pressure drop-related as for thermal-hydraulic one. The 92% of the patents analyzed were issued form nuclear companies of USA, France and Germany. Among the patents dealing with mechanical subjects, the fretting failure and fuel rod support-related is more than the pressure drop-related among the patents of thermal-hydraulic subjects. The number of patents issued from Japan ranks just after Germany i.e., the 4th country. It is thought that much concern as well as investment should be increased in this field, the patent of nuclear components. (author). 2 tabs., 5 figs.

  5. FIVPET Flow-Induced Vibration Test Report (1) - Candidate Spacer Grid Type I (Optimized H Type)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Hee; Kang, Heung Seok; Yoon, Kyung Ho; Song, Kee Nam; Kim, Jae Yong

    2006-03-15

    The flow-induced vibration (FIV) test using a 5x5 partial fuel assembly was performed to evaluate mechanical/structural performance of the candidate spacer grid type I (Optimized H shape). From the measured vibration response of the test bundle and the flow parameters, design features of the spacer strap can be analyzed in the point of vibration and hydraulic aspect, and also compared with other spacer strap in simple comparative manner. Furthermore, the FIV test will contributes to understand behaviors of nuclear fuel in operating reactor. The FIV test results will be used to verify the theoretical model of fuel rod and assembly vibration. The aim of this report is to present the results of the FIV test of partial fuel assembly and to introduce the detailed test methodology and analysis procedure. In chapter 2, the overall configuration of test bundle and instrumented tube is remarked and chapter 3 will introduce the test facility (FIVPET) and test section. Chapter 4 deals with overall test condition and procedure, measurement and data acquisition devices, instrumentation equipment and calibration, and error analysis. Finally, test result of vibration and pressure fluctuation is presented and discussed in chapter 5.

  6. Experimental benchmark data for PWR rod bundle with spacer-grids

    International Nuclear Information System (INIS)

    Dominguez-Ontiveros, Elvis E.; Hassan, Yassin A.; Conner, Michael E.; Karoutas, Zeses

    2012-01-01

    In numerical simulations of fuel rod bundle flow fields, the unsteady Navier–Stokes equations have to be solved in order to determine the time (phase) dependent characteristics of the flow. In order to validate the simulations results, detailed comparison with experimental data must be done. Experiments investigating complex flows in rod bundles with spacer grids that have mixing devices (such as flow mixing vanes) have mostly been performed using single-point measurements. In order to obtain more details and insight on the discrepancies between experimental and numerical data as well as to obtain a global understanding of the causes of these discrepancies, comparisons of the distributions of complete phase-averaged velocity and turbulence fields for various locations near spacer-grids should be performed. The experimental technique Particle Image Velocimetry (PIV) is capable of providing such benchmark data. This paper describes an experimental database obtained using two-dimensional Time Resolved Particle Image Velocimetry (TR-PIV) measurements within a 5 × 5 PWR rod bundle with spacer-grids that have flow mixing vanes. One of the unique characteristic of this set-up is the use of the Matched Index of Refraction technique employed in this investigation to allow complete optical access to the rod bundle. This unique feature allows flow visualization and measurement within the bundle without rod obstruction. This approach also allows the use of high temporal and spatial non-intrusive dynamic measurement techniques namely TR-PIV to investigate the flow evolution below and immediately above the spacer. The experimental data presented in this paper includes explanation of the various cases tested such as test rig dimensions, measurement zones, the test equipment and the boundary conditions in order to provide appropriate data for comparison with Computational Fluid Dynamics (CFD) simulations. Turbulence parameters of the obtained data are presented in order to gain

  7. USE OF ANTIBIOTIC CEMENT SPACERS/BEADS IN TREATMENT ...

    African Journals Online (AJOL)

    ABSTRACT. Background: Chronic musculoskeletal infection involving bone present a big challenge to orthopaedic surgeons. ... Current data has demonstrated that the use of .... Antibiotic spacers are effective and add value in the treament of ...

  8. Analytical prediction of fuel assembly spacer grid loss coefficient

    International Nuclear Information System (INIS)

    Lim, J. S.; Nam, K. I.; Park, S. K.; Kwon, J. T.; Park, W. J.

    2002-01-01

    The analytical prediction model of the fuel assembly spacer grid pressure loss coefficient has been studied. The pressure loss of gap between the test section wall and spacer grid was separated from the current model and the different friction drag coefficient on spacer straps from high Reynolds number region were used to low Reynolds number region. The analytical model has been verified based on the hydraulic pressure drop test results for the spacer grids of three types for 5x5, 16x16(or 17x17) arrays. The analytical model predicts the pressure loss coefficients obtained from test results within the maximum errors of 12% and 7% for 5x5 test bundle and full size bundle, respectively, at Reynolds number 500,000 of the core operating condition. This result shows that the analytical model can be used for research and design change of the nuclear fuel assembly

  9. Response of an electrostatic probe for a right cylindrical spacer

    DEFF Research Database (Denmark)

    Rerup, T; Crichton, George C; McAllister, Iain Wilson

    1994-01-01

    During the last decade many experimental studies of surface charge phenomena have been undertaken employing right cylindrical spacers. Measurement of the surface charge was performed using small electrostatic field probes to scan across the dielectric surface. Charges are electrostatically induced...

  10. Surface-Tethered Iterative Carbohydrate Synthesis (STICS): A spacer study

    Science.gov (United States)

    Ganesh, N. Vijaya; Fujikawa, Kohki; Tan, Yih Horng; Nigudkar, Swati S.

    2013-01-01

    Comparative study of STICS using HPLC-assisted experimental set-up clearly demonstrated benefits of using longer spacer-anchoring systems. The use of mixed self-assembled monolayers helps to provide the required space for glycosylation reaction around the immobilized glycosyl acceptor. Both extension of the spacer length and using mixed self-assembled monolayers help to promote reaction and the beneficial effects may include moving the glycosyl acceptor further out into solution and providing additional conformational flexibility. It is possible that surface-immobilized glycosyl acceptors with a longer spacer (C8-O-C8)-lipoic acid have a higher tendency to mimic a solution-phase reaction environment than that of acceptors with shorter spacers. PMID:23822088

  11. Optimized Design of Spacer in Electrodialyzer Using CFD Simulation Method

    Science.gov (United States)

    Jia, Yuxiang; Yan, Chunsheng; Chen, Lijun; Hu, Yangdong

    2018-06-01

    In this study, the effects of length-width ratio and diversion trench of the spacer on the fluid flow behavior in an electrodialyzer have been investigated through CFD simulation method. The relevant information, including the pressure drop, velocity vector distribution and shear stress distribution, demonstrates the importance of optimized design of the spacer in an electrodialysis process. The results show width of the diversion trench has a great effect on the fluid flow compared with length. Increase of the diversion trench width could strength the fluid flow, but also increase the pressure drop. Secondly, the dead zone of the fluid flow decreases with increase of length-width ratio of the spacer, but the pressure drop increases with the increase of length-width ratio of the spacer. So the appropriate length-width ratio of the space should be moderate.

  12. Orthognathic model surgery with LEGO key-spacer.

    Science.gov (United States)

    Tsang, Alfred Chee-Ching; Lee, Alfred Siu Hong; Li, Wai Keung

    2013-12-01

    A new technique of model surgery using LEGO plates as key-spacers is described. This technique requires less time to set up compared with the conventional plaster model method. It also retains the preoperative setup with the same set of models. Movement of the segments can be measured and examined in detail with LEGO key-spacers. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Bioinformatics analyses of Shigella CRISPR structure and spacer classification.

    Science.gov (United States)

    Wang, Pengfei; Zhang, Bing; Duan, Guangcai; Wang, Yingfang; Hong, Lijuan; Wang, Linlin; Guo, Xiangjiao; Xi, Yuanlin; Yang, Haiyan

    2016-03-01

    Clustered regularly interspaced short palindromic repeats (CRISPR) are inheritable genetic elements of a variety of archaea and bacteria and indicative of the bacterial ecological adaptation, conferring acquired immunity against invading foreign nucleic acids. Shigella is an important pathogen for anthroponosis. This study aimed to analyze the features of Shigella CRISPR structure and classify the spacers through bioinformatics approach. Among 107 Shigella, 434 CRISPR structure loci were identified with two to seven loci in different strains. CRISPR-Q1, CRISPR-Q4 and CRISPR-Q5 were widely distributed in Shigella strains. Comparison of the first and last repeats of CRISPR1, CRISPR2 and CRISPR3 revealed several base variants and different stem-loop structures. A total of 259 cas genes were found among these 107 Shigella strains. The cas gene deletions were discovered in 88 strains. However, there is one strain that does not contain cas gene. Intact clusters of cas genes were found in 19 strains. From comprehensive analysis of sequence signature and BLAST and CRISPRTarget score, the 708 spacers were classified into three subtypes: Type I, Type II and Type III. Of them, Type I spacer referred to those linked with one gene segment, Type II spacer linked with two or more different gene segments, and Type III spacer undefined. This study examined the diversity of CRISPR/cas system in Shigella strains, demonstrated the main features of CRISPR structure and spacer classification, which provided critical information for elucidation of the mechanisms of spacer formation and exploration of the role the spacers play in the function of the CRISPR/cas system.

  14. Electrical bistabilities and memory stabilities of nonvolatile bistable devices fabricated utilizing C60 molecules embedded in a polymethyl methacrylate layer

    International Nuclear Information System (INIS)

    Cho, Sung Hwan; Lee, Dong Ik; Jung, Jae Hun; Kim, Tae Whan

    2009-01-01

    Current-voltage (I-V) measurements on Al/fullerene (C 60 ) molecules embedded in polymethyl methacrylate/Al devices at 300 K showed a current bistability due to the existence of the C 60 molecules. The on/off ratio of the current bistability for the memory devices was as large as 10 3 . The retention time of the devices was above 2.5 x 10 4 s at room temperature, and cycling endurance tests on these devices indicated that the ON and OFF currents showed no degradation until 50 000 cycles. Carrier transport mechanisms for the nonvolatile bistable devices are described on the basis of the I-V experimental and fitting results.

  15. Buckling behavior analysis of spacer grid by lateral impact load

    International Nuclear Information System (INIS)

    Yoon, Kyung Ho; Kang, Heung Seok; Kim, Hyung Kyu; Song, Kee Nam

    2000-05-01

    The spacer grid is one of the main structural components in the fuel assembly, Which supports the fuel rods, guides cooling water, and protects the system from an external impact load, such as earthquakes. Therefore, the mechanical and structural properties of the spacer grids must be extensively examined while designing it. In this report, free fall type shock tests on the several kinds of the specimens of the spacer grids were also carried out in order to compare the results among the candidate grids. A free fall carriage on the specimen accomplishes the test. In addition to this, a finite element method for predicting the critical impact strength of the spacer grids is described. FE method on the buckling behavior of the spacer grids are performed for a various array of sizes of the grids considering that the spacer grid is an assembled structure with thin-walled plates and imposing proper boundary conditions by nonlinear dynamic impact analysis using ABAQUS/explicit code. The simulated results results also similarly predicted the local buckling phenomena and were found to give good correspondence with the shock test results

  16. CTF/STAR-CD off-line coupling for simulation of crossflow caused by mixing vane spacers in rod bundles

    International Nuclear Information System (INIS)

    Avramova, Maria

    2011-01-01

    Understanding the impact of the spacer grids on the reactor core thermal-hydraulics involves experimental mockup tests, numerical simulations, and development of reliable empirical or semi-empirical models. The state-of-the-art in modeling spacer effects on the thermal-hydraulic performance of the flow in Light Water Reactor (LWR) rod bundles employs numerical experiments by means of Computational Fluid Dynamics (CFD) calculations. The capabilities of the CFD codes are usually being validated against mock-up tests. Once validated, the CFD predictions can be used for improvement and development of more sophisticated models of the subchannel codes. Because of the involved computational cost, CFD codes can not be yet efficiently utilized for full bundle predictions, while advanced subchannel codes are a powerful tool for LWR safety and design analyses. Subchannel analyses are used for whole LWR core evaluations with relatively short CPU times and reasonable computer resources. The objectives of the presented work were to develop, implement, and qualify an innovative spacer grid model utilizing the Computational Fluid Dynamics within a framework of an efficient subchannel analysis tool. A methodology was developed for off-line coupling between the CFD code STAR-CD and the subchannel code CTF. The developed coupling scheme is flexible in axial mesh overlays. It was developed to be easily adapted to any pair of a CFD and a subchannel code. Separate modeling of the spacer grid effects on the diffusive and on the convective processes was implemented and successfully validated against experimental data. (author)

  17. The potential of standard and modified feed spacers for biofouling control

    KAUST Repository

    Araújo, Paula A.

    2012-06-01

    The impact of feed spacers on initial feed channel pressure (FCP) drop, FCP increase and biomass accumulation has been studied in membrane fouling simulators using feed spacers applied in commercially available nanofiltration and reverse osmosis spiral wound membrane modules. All spacers had a similar geometry.Our studies showed that biofouling was not prevented by (i) variation of spacer thickness, (ii) feed spacer orientation, (iii) feed spacer coating with silver, copper or gold and (iv) using a biostatic feed spacer. At constant feed flow, a lower FCP and FCP increase were observed for a thicker feed spacer. At constant linear flow velocity, roughly the same FCP development and biomass accumulation were found irrespective of the feed spacer thickness: hydrodynamics and substrate load were more important for development and impact of biofouling than the thickness of currently applied spacers. Use of biostatic and metal coated spacers were not effective for biofouling control. The same small reduction of biofouling rate was observed with copper and silver coated spacers as well as uncoated 45° rotated spacers.The studied modified spacers were not effective for biofouling prevention and control. The impact of biofouling on FCP increase was reduced significantly by a lower linear flow velocity, while spacer orientation and spacer thickness in membrane modules had a smaller but still significant effect. © 2012 Elsevier B.V.

  18. The potential of standard and modified feed spacers for biofouling control

    KAUST Repository

    Araú jo, Paula A.; Kruithof, Joop C.; van Loosdrecht, Mark C.M.; Vrouwenvelder, Johannes S.

    2012-01-01

    The impact of feed spacers on initial feed channel pressure (FCP) drop, FCP increase and biomass accumulation has been studied in membrane fouling simulators using feed spacers applied in commercially available nanofiltration and reverse osmosis spiral wound membrane modules. All spacers had a similar geometry.Our studies showed that biofouling was not prevented by (i) variation of spacer thickness, (ii) feed spacer orientation, (iii) feed spacer coating with silver, copper or gold and (iv) using a biostatic feed spacer. At constant feed flow, a lower FCP and FCP increase were observed for a thicker feed spacer. At constant linear flow velocity, roughly the same FCP development and biomass accumulation were found irrespective of the feed spacer thickness: hydrodynamics and substrate load were more important for development and impact of biofouling than the thickness of currently applied spacers. Use of biostatic and metal coated spacers were not effective for biofouling control. The same small reduction of biofouling rate was observed with copper and silver coated spacers as well as uncoated 45° rotated spacers.The studied modified spacers were not effective for biofouling prevention and control. The impact of biofouling on FCP increase was reduced significantly by a lower linear flow velocity, while spacer orientation and spacer thickness in membrane modules had a smaller but still significant effect. © 2012 Elsevier B.V.

  19. Improved spacers for high temperature gas-cooled heat exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Nordstroem, L A [Swiss Federal Institute for Reactor Research, Wuerenlingen (Switzerland)

    1984-07-01

    Experimental and analytical investigations in the field of heat exchanger thermohydraulics have been performed at EIR for many years, Basic studies have been carried out on heat transfer and pressure loss for tube bundles of different geometries and tube surfaces. As a part of this overall R+D programme for heat exchangers, investigations have been carried out on spacer pressure loss in bundles with longitudinal flow. An analytical spacer pressure loss model was developed which could handle different types of subchannel within the bundle. The model has been evaluated against experiments, using about 25 spacers of widely differing geometries. In a gas-cooled reactor it is important to keep the pressure loss over the primary circuit heat exchangers to a minimum. In exchangers with grid spacers these contribute a significant proportion of the overall bundle losses. For example, in the HHT Recuperator, with a shell-side pressure loss of 3.5 % of the inlet pressure, the spacers cause about one half of this loss. Reducing the loss to, say, 2.5 % results in an overall increase in plant efficiency by more than 1 % - a significant improvement Preliminary analysis identified 5 geometries in particular which were chosen for experimental evaluation as part of a joint project with the SULZER Company, to develop a low pressure-loss spacer for HHT heat exchangers (longitudinal counter-flow He/He and He/H{sub 2}O designs). The aim of the tests was to verify the low pressure-loss characteristics of these spacer grid types, as well as the quality of the results calculated by the computer code analytical model. The experimental and analytical results are compared in this report.

  20. Effect of the spacer group nature on the optical and electrical properties of confined poly( p-phenylene vinylene) derivatives

    Science.gov (United States)

    Benzarti-Ghédira, Maha; Zahou, Imen; Hrichi, Haikel; Jaballah, Nejmeddine; Ben Chaâbane, Rafik; Majdoub, Mustapha; Ben Ouada, Hafedh

    2015-09-01

    This study is an investigation about the effect of chemical modification on the morphological, optical and electrical properties of semiconducting organic thin films. Two confined poly( p-phenylene vinylene) (PPV)-type polymers containing different spacer groups were studied: P1 has an isopropylidene spacer group and P2 with hexafluoroisopropylidene spacer. The UV-Vis absorption and PL analysis showed a stronger π- π interaction in the P1 film; in P2, the π-stacking is limited by the introduction of a bulky trifluoromethyl (CF3) groups on the spacer units. The P2 exhibits a better film quality as illustrated by the atomic force microscopy. The HOMO and LUMO energy levels and electrochemical band gap of the polymers were determinate by the cyclic voltammetry. The electrical properties of ITO/PPV derivative/Al diodes were investigated by means of current-voltage and show a space-charge-limited current conduction mechanism with higher mobility in the P2 thin layer. The impedance spectra of the devices can be discussed in terms of an equivalent circuit model designed as a parallel resistance ( R p) and capacitance ( C p) network in series with a resistance.

  1. Gene transfer device utilizing micron-spiked electrodes produced by the self-organization phenomenon of Fe-alloy.

    Science.gov (United States)

    Miyano, Naoki; Inoue, Yuuki; Teramura, Yuji; Fujii, Keisuke; Tsumori, Fujio; Iwata, Hiroo; Kotera, Hidetoshi

    2008-07-01

    In the diffusional phase transformation of two-phase alloys, the new phase precipitates form the matrix phase at specific temperatures, followed by the formation of a mixed microstructure comprising the precipitate and the matrix. It has been found that by specific chemical-etching treatment, the precipitate in Fe-25Cr-6Ni alloy projects substantially and clusters at the surface. The configuration of the precipitate has an extremely high aspect ratio: it is several microns in width and several tens of microns in length (known as micron-spiked). This study targets the development of a gene transfer device with a micro-spike produced based on the self-organization phenomenon of the Fe-25Cr-6Ni alloy. With this spike-projected device, we tried to efficiently transfer plasmid DNA into adherent cells by electric pulse-triggered gene transfer using a plasmid-loaded electrode (electroporation-based reverse transfection). The spiked structure was applied to a substrate of the device to allow efficient gene transfer into adherent cells, although the general substrate was flat and had a smooth surface. The results suggest that this unique spike-projected device has potential applications in gene transfer devices for the analysis of the human genome in the post-genome period.

  2. Numerical analysis of the spacer grids' compression strength

    Energy Technology Data Exchange (ETDEWEB)

    Schettino, C.F.M.; Gouvea, J.P.; Medeiros, N., E-mail: carlosschettino@inb.gov.br, E-mail: jpg@metal.eeimvr.uff.br [Universidade Federal Fluminense (UFF), Volta Redonda, RJ (Brazil). Programa de Engenharia Metalurgica

    2013-07-01

    Among the components of the fuel assembly, the spacer grids play an important structural role during the energy generation process, mainly for their requirement to have enough structural strength to withstand lateral impact loads, due to fuel assembly shipping/handling and due to forces outcome from postulated accidents (earthquake and LOCA). This requirement ensures a proper geometry for cooling and for guide thimble straightness in the fuel assembly. In this way, the understanding of the macroscopic mechanical behavior of this component becomes essential even to any subsequent geometrical modifications to optimize the flue assemblies' structural behavior. In the present work, three-dimensional finite element models destined to provide consistent predictions of 16X16-type spacer grids lateral strength were proposed. Firstly, buckling tests based on results available in the literature were performed to establish a methodology for spacer grid finite element-based modeling. The, by considering a spacer grid interesting geometry and some possible variations associated to its fabrication, tolerance, the proposed numerical models were submitted to compression conditions to calculate the buckling force. Also, these models were validated for comparison with experimental buckling load results. Comparison of buckling predictions combined to observations of actual and simulated deformed spacer grids geometries permitted to verify the consistency and applicability of the proposed models. Thus, these numerical results show a good agreement between the and the experimental results. (author)

  3. Impact of spacer thickness on biofouling in forward osmosis

    KAUST Repository

    Valladares Linares, Rodrigo

    2014-06-01

    Forward osmosis (FO) indirect desalination systems integrate wastewater recovery with seawater desalination. Niche applications for FO systems have been reported recently, due to the demonstrated advantages compared to conventional high-pressure membrane processes such as nanofiltration (NF) and reverse osmosis (RO). Among them, wastewater recovery has been identified to be particularly suitable for practical applications. However, biofouling in FO membranes has rarely been studied in applications involving wastewater effluents. Feed spacers separating the membrane sheets in cross-flow systems play an important role in biofilm formation. The objective of this study was to determine the influence of feed spacer thickness (28, 31 and 46mil) on biofouling development and membrane performance in a FO system, using identical cross-flow cells in parallel studies. Flux development, biomass accumulation, fouling localization and composition were determined and analyzed. For all spacer thicknesses, operated at the same feed flow and the same run time, the same amount of biomass was found, while the flux reduction decreased with thicker spacers. These observations are in good agreement with biofouling studies for RO systems, considering the key differences between FO and RO. Our findings contradict previous cross-flow studies on particulate/colloidal fouling, where higher cross-flow velocities improved system performance. Thicker spacers reduced the impact of biofouling on FO membrane flux. © 2014 Elsevier Ltd.

  4. Impact of spacer thickness on biofouling in forward osmosis.

    Science.gov (United States)

    Valladares Linares, R; Bucs, Sz S; Li, Z; AbuGhdeeb, M; Amy, G; Vrouwenvelder, J S

    2014-06-15

    Forward osmosis (FO) indirect desalination systems integrate wastewater recovery with seawater desalination. Niche applications for FO systems have been reported recently, due to the demonstrated advantages compared to conventional high-pressure membrane processes such as nanofiltration (NF) and reverse osmosis (RO). Among them, wastewater recovery has been identified to be particularly suitable for practical applications. However, biofouling in FO membranes has rarely been studied in applications involving wastewater effluents. Feed spacers separating the membrane sheets in cross-flow systems play an important role in biofilm formation. The objective of this study was to determine the influence of feed spacer thickness (28, 31 and 46 mil) on biofouling development and membrane performance in a FO system, using identical cross-flow cells in parallel studies. Flux development, biomass accumulation, fouling localization and composition were determined and analyzed. For all spacer thicknesses, operated at the same feed flow and the same run time, the same amount of biomass was found, while the flux reduction decreased with thicker spacers. These observations are in good agreement with biofouling studies for RO systems, considering the key differences between FO and RO. Our findings contradict previous cross-flow studies on particulate/colloidal fouling, where higher cross-flow velocities improved system performance. Thicker spacers reduced the impact of biofouling on FO membrane flux. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Analyses of the Collapse Behavior of a Spacer Grid

    International Nuclear Information System (INIS)

    Jang, Myung-Geun; Na, Geum Ju; Jag, Yeon-Hui; Kim, Hee Cheol; Kim, Jong-Bong; Kim, Jaeyoug

    2016-01-01

    In order to investigate the protection capability of a spacer grid assembly for impact load, a hammer impact test has been carried out. The crush strength is measured in the hammer impact test. Song et al. carried out the experiment and finite element analysis for the hammer impact test for various weld line depth. Park et al. designed the spacer grid shape to get required crush strength via finite element analysis. Song et al. also optimized the spacer grid shape to maximize the crush strength, and carried out the finite element analysis for the hammer impact test considering the weld properties. Kim et al. carried out finite element analysis for various guide tube hole shape and compared the crush shape and crush strength. In this study, the effect of shape defect on the crush behavior in the hammer impact test is investigated. The spacer grid cannot be exactly the square. Therefore a lateral displacement (imperfection) is imposed to square spacer grid and then hammer impact is carried out. The effect of the lateral imperfection on the crush strength is investigated. The effect of the shape defect on the crushing behavior in the hammer impact test is investigated by finite element analysis. It is shown that the collapse become severe as the lateral imperfection displacement increases, especially when the imperfection is greater than or equal to 0.7 mm

  6. Numerical analysis of the spacer grids' compression strength

    International Nuclear Information System (INIS)

    Schettino, C.F.M.; Gouvea, J.P.; Medeiros, N.

    2013-01-01

    Among the components of the fuel assembly, the spacer grids play an important structural role during the energy generation process, mainly for their requirement to have enough structural strength to withstand lateral impact loads, due to fuel assembly shipping/handling and due to forces outcome from postulated accidents (earthquake and LOCA). This requirement ensures a proper geometry for cooling and for guide thimble straightness in the fuel assembly. In this way, the understanding of the macroscopic mechanical behavior of this component becomes essential even to any subsequent geometrical modifications to optimize the flue assemblies' structural behavior. In the present work, three-dimensional finite element models destined to provide consistent predictions of 16X16-type spacer grids lateral strength were proposed. Firstly, buckling tests based on results available in the literature were performed to establish a methodology for spacer grid finite element-based modeling. The, by considering a spacer grid interesting geometry and some possible variations associated to its fabrication, tolerance, the proposed numerical models were submitted to compression conditions to calculate the buckling force. Also, these models were validated for comparison with experimental buckling load results. Comparison of buckling predictions combined to observations of actual and simulated deformed spacer grids geometries permitted to verify the consistency and applicability of the proposed models. Thus, these numerical results show a good agreement between the and the experimental results. (author)

  7. A non-electrostatic spacer for aerosol delivery

    DEFF Research Database (Denmark)

    Bisgaard, H; Anhøj, J; Klug, B

    1995-01-01

    A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide...... pressurised metered dose inhaler (p-MDI) to minimise the electrostatic charge on the plastic. The procedure prolonged the half life (t1/2) of the aerosol in the Nebuhaler from nine to 32 seconds. A normal cleaning procedure reduced the aerosol t1/2 back to baseline. The t1/2 of the aerosol in the metal spacer...... was 27 seconds and independent of the use of p-MDI. In vitro the maximum dose of budesonide from a p-MDI, expressed as a percentage of the nominal dose, was 56% from the non-electrostatic spacer, 61% from the Nebuhaler, 45% from the Babyhaler, and 30% from the AeroChamber. In 124 children, age 6 months...

  8. Impact of spacer thickness on biofouling in forward osmosis

    KAUST Repository

    Valladares Linares, Rodrigo; Bucs, Szilard; Li, Z.; AbuGhdeeb, M.; Amy, Gary L.; Vrouwenvelder, Johannes S.

    2014-01-01

    Forward osmosis (FO) indirect desalination systems integrate wastewater recovery with seawater desalination. Niche applications for FO systems have been reported recently, due to the demonstrated advantages compared to conventional high-pressure membrane processes such as nanofiltration (NF) and reverse osmosis (RO). Among them, wastewater recovery has been identified to be particularly suitable for practical applications. However, biofouling in FO membranes has rarely been studied in applications involving wastewater effluents. Feed spacers separating the membrane sheets in cross-flow systems play an important role in biofilm formation. The objective of this study was to determine the influence of feed spacer thickness (28, 31 and 46mil) on biofouling development and membrane performance in a FO system, using identical cross-flow cells in parallel studies. Flux development, biomass accumulation, fouling localization and composition were determined and analyzed. For all spacer thicknesses, operated at the same feed flow and the same run time, the same amount of biomass was found, while the flux reduction decreased with thicker spacers. These observations are in good agreement with biofouling studies for RO systems, considering the key differences between FO and RO. Our findings contradict previous cross-flow studies on particulate/colloidal fouling, where higher cross-flow velocities improved system performance. Thicker spacers reduced the impact of biofouling on FO membrane flux. © 2014 Elsevier Ltd.

  9. Spacer engineered Trigate SOI TFET: An investigation towards harsh temperature environment applications

    Science.gov (United States)

    Mallikarjunarao; Ranjan, Rajeev; Pradhan, K. P.; Artola, L.; Sahu, P. K.

    2016-09-01

    In this paper, a novel N-channel Tunnel Field Effect Transistor (TFET) i.e., Trigate Silicon-ON-Insulator (SOI) N-TFET with high-k spacer is proposed for better Sub-threshold swing (SS) and OFF-state current (IOFF) by keeping in mind the sensitivity towards temperature. The proposed model can achieve a Sub-threshold swing less than 35 mV/decade at various temperatures, which is desirable for designing low power CTFET for digital circuit applications. In N-TFET source doping has a significant effect on the ON-state current (ION) level; therefore more electrons will tunnel from source to channel region. High-k Spacer i.e., HfO2 is used to enhance the device performance and also it avoids overlapping of transistors in an integrated circuits (IC's). We have designed a reliable device by performing the temperature analysis on Transfer characteristics, Drain characteristics and also on various performance metrics like ON-state current (ION), OFF-state current (IOFF), ION/IOFF, Trans-conductance (gm), Trans-conductance Generation Factor (TGF), Sub-threshold Swing (SS) to observe the applications towards harsh temperature environment.

  10. A novel automated device for rapid nucleic acid extraction utilizing a zigzag motion of magnetic silica beads

    International Nuclear Information System (INIS)

    Yamaguchi, Akemi; Matsuda, Kazuyuki; Uehara, Masayuki; Honda, Takayuki; Saito, Yasunori

    2016-01-01

    We report a novel automated device for nucleic acid extraction, which consists of a mechanical control system and a disposable cassette. The cassette is composed of a bottle, a capillary tube, and a chamber. After sample injection in the bottle, the sample is lysed, and nucleic acids are adsorbed on the surface of magnetic silica beads. These magnetic beads are transported and are vibrated through the washing reagents in the capillary tube under the control of the mechanical control system, and thus, the nucleic acid is purified without centrifugation. The purified nucleic acid is automatically extracted in 3 min for the polymerase chain reaction (PCR). The nucleic acid extraction is dependent on the transport speed and the vibration frequency of the magnetic beads, and optimizing these two parameters provided better PCR efficiency than the conventional manual procedure. There was no difference between the detection limits of our novel device and that of the conventional manual procedure. We have already developed the droplet-PCR machine, which can amplify and detect specific nucleic acids rapidly and automatically. Connecting the droplet-PCR machine to our novel automated extraction device enables PCR analysis within 15 min, and this system can be made available as a point-of-care testing in clinics as well as general hospitals. - Highlights: • Automatic nucleic acid extraction is performed in 3 min. • Zigzag motion of magnetic silica beads yields rapid and efficient extraction. • The present our device provides better performance than the conventional procedure.

  11. Experimental study of mechanical properties on spacer in NHR

    International Nuclear Information System (INIS)

    Jiang Yueyuan; Shi Jibing; Xu Yong

    2007-01-01

    The spacer of NHR-200 is composed mainly of the inner, outer and cornual strips which are ranged in egg-crate of 12 x 12-3. First, the pre-distortion of three kinds of three-arc springs on reactor working condition and their related clipping-force ranges are analyzed in this paper. Secondly, the mechanical experiments of 1:1 prototype, such as the load-distortion experiments, which the load and distortion are respectively measured by strain gauge and displacement sensor, of three kinds of springs, rigid supports and the spacers in two different directions are carried out on a special experimental facility. The experimental results show that the spacer can completely meet the design demands of mechanical properties of the fuel assemblies in NHR-200. (authors)

  12. Effect of a spacer moiety on radiometal labelled Neurotensin derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Mascarin, A.; Valverde, I.E.; Mindt, T.L. [Univ. of Basel Hospital (Switzerland). Div. of Radiopharmaceutical Chemistry

    2013-07-01

    The binding sequence of the regulatory peptide Neurotensin, NT(8-13), represents a promising tumour-specific vector for the development of radiopeptides useful in nuclear oncology for the diagnosis (imaging) and therapy of cancer. A number of radiometal-labelled NT(8-13) derivatives have been reported, however, the effect of the spacer which connects the vector with the radiometal complex has yet not been investigated systematically. Because a spacer moiety can influence potentially important biological characteristics of radiopeptides, we synthesized three [DOTA({sup 177}Lu)]-X-NT(8-13) derivatives and evaluated the effect of a spacer (X) on the physico-chemical properties of the conjugate including lipophilicity, stability, and in vitro receptor affinity and cell internalization. (orig.)

  13. Lower end fitting debris collector and end cap spacer grid

    International Nuclear Information System (INIS)

    Bryan, W.J.

    1990-01-01

    This patent describes a nuclear reactor having fuel assemblies including an upper end fitting and spaced nuclear fuel rod spacer grids for supporting and spacing a plurality of elongated nuclear fuel rods. Each includes a hollow active portion of nuclear fuel filled cladding intermediate the rod ends and tapering end cap of solid material with a circumferential groove on the rod end which first encounters reactor coolant flow, a lower end filtering debris collector and end cap spacer grid for capturing and retaining deleterious debris carried by reactor coolant before it enters the active region of a fuel assembly and creates fuel rod cladding damage

  14. Spacer grid for a nuclear reactor fuel assembly

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1978-01-01

    The spacer grid consists of pairs of plates forming rectangular cells and enclosing the cylindrical fuel assemblies. They have got rigid as well as elastic projections extending into the cells and holding the fuel assemblies. Additional pairs of plates are arranged in about the center of the grid of plates. They have got only elastic projections extending on both sides of the plates into one cell each. This spacer grid may be used for reactor cores with and without fuel channels. By the combination of spring-elastic and rigid projections there is obtained a reinforced outer tie. Hydraulic pressure losses, parasitic neutron capture, and hot spots are essentially reduced. (DG) [de

  15. Biomechanical Analysis of an Expandable Lumbar Interbody Spacer.

    Science.gov (United States)

    Soriano-Baron, Hector; Newcomb, Anna G U S; Malhotra, Devika; Palma, Atilio E; Martinez-Del-Campo, Eduardo; Crawford, Neil R; Theodore, Nicholas; Kelly, Brian P; Kaibara, Taro

    2018-06-01

    Recently developed expandable interbody spacers are widely accepted in spinal surgery; however, the resulting biomechanical effects of their use have not yet been fully studied. We analyzed the biomechanical effects of an expandable polyetheretherketone interbody spacer inserted through a bilateral posterior approach with and without different modalities of posterior augmentation. Biomechanical nondestructive flexibility testing was performed in 7 human cadaveric lumbar (L2-L5) specimens followed by axial compressive loading. Each specimen was tested under 6 conditions: 1) intact, 2) bilateral L3-L4 cortical screw/rod (CSR) alone, 3) WaveD alone, 4) WaveD + CSR, 5) WaveD + bilateral L3-L4 pedicle screw/rod (PSR), and 6) WaveD + CSR/PSR, where CSR/PSR was a hybrid construct comprising bilateral cortical-level L3 and pedicle-level L4 screws interconnected by rods. The range of motion (ROM) with the interbody spacer alone decreased significantly compared with the intact condition during flexion-extension (P = 0.02) but not during lateral bending or axial rotation (P ≥ 0.19). The addition of CSR or PSR to the interbody spacer alone condition significantly decreased the ROM compared with the interbody spacer alone (P ≤ 0.002); and WaveD + CSR, WaveD + PSR, and WaveD + CSR/PSR (hybrid) (P ≥ 0.29) did not differ. The axial compressive stiffness (resistance to change in foraminal height during compressive loading) with the interbody spacer alone did not differ from the intact condition (P = 0.96), whereas WaveD + posterior instrumentation significantly increased compressive stiffness compared with the intact condition and the interbody spacer alone (P ≤ 0.001). The WaveD alone significantly reduced ROM during flexion-extension while maintaining the axial compressive stiffness. CSR, PSR, and CSR/PSR hybrid constructs were all effective in augmenting the expandable interbody spacer system and improving its stability. Copyright © 2018 Elsevier Inc. All

  16. A Critical Evaluation on Programming Paradigms to Achieve Optimal Resource Utilization of Mobile Softwares in Mobile Devices

    OpenAIRE

    Selvakumar Samuel; Arangasamy Kovalan

    2014-01-01

    This paper evaluates the features of mainstream programming paradigms. Imperative, object oriented programming and functional programming concepts are considered here. This is an effort to identify the programming paradigms which consume less resource from mobile devices. Designers usually depend on the programming languages, language oriented programming design is in current practice. Choosing appropriate programming paradigms during the mobile application design is not in practice now; Fail...

  17. Utilization of a Network of Small Magnetic Confinement Fusion Devices for Mainstream Fusion Research. Report of a Coordinated Research Project 2011–2016

    International Nuclear Information System (INIS)

    2016-12-01

    The IAEA actively promotes the development of controlled fusion as a source of energy. Through its coordinated research activities, the IAEA helps Member States to exchange and establish scientific and technical knowledge required for the design, construction and operation of a fusion reactor. Due to their compactness, flexibility and low operation costs, small fusion devices are a great resource for supporting and accelerating the development of mainstream fusion research on large fusion devices such as the International Thermonuclear Experimental Reactor. They play an important role in investigating the physics of controlled fusion, developing innovative technologies and diagnostics, testing new materials, training highly qualified personnel for larger fusion facilities, and supporting educational programmes for young scientists. This publication reports on the research work accomplished within the framework of the Coordinated Research Project (CRP) on Utilization of the Network of Small Magnetic Confinement Fusion Devices for Mainstream Fusion Research, organized and conducted by the IAEA in 2011–2016. The CRP has contributed to the coordination of a network of research institutions, thereby enhancing international collaboration through scientific visits, joint experiments and the exchange of information and equipment. A total of 16 institutions and 14 devices from 13 Member States participated in this CRP (Belgium, Bulgaria, Canada, China, Costa Rica, the Czech Republic, the Islamic Republic of Iran, Kazakhstan, Pakistan, Portugal, the Russian Federation, Ukraine and the United Kingdom).

  18. Evaluation of lead/carbon devices for utility applications : a study for the DOE Energy Storage Program.

    Energy Technology Data Exchange (ETDEWEB)

    Walmet, Paula S. (MeadWestvaco Corporation,North Charleston, SC)

    2009-06-01

    This report describes the results of a three-phase project that evaluated lead-based energy storage technologies for utility-scale applications and developed carbon materials to improve the performance of lead-based energy storage technologies. In Phase I, lead/carbon asymmetric capacitors were compared to other technologies that used the same or similar materials. At the end of Phase I (in 2005) it was found that lead/carbon asymmetric capacitors were not yet fully developed and optimized (cost/performance) to be a viable option for utility-scale applications. It was, however, determined that adding carbon to the negative electrode of a standard lead-acid battery showed promise for performance improvements that could be beneficial for use in utility-scale applications. In Phase II various carbon types were developed and evaluated in lead-acid batteries. Overall it was found that mesoporous activated carbon at low loadings and graphite at high loadings gave the best cycle performance in shallow PSoC cycling. Phase III studied cost/performance benefits for a specific utility application (frequency regulation) and the full details of this analysis are included as an appendix to this report.

  19. Perceptions of the risk of child abduction or loss and the utility of child electronic security devices.

    Science.gov (United States)

    Dixon, R M; Pasnak, R

    1997-09-01

    Perceptions of the susceptibility of young children to becoming lost or being abducted, and of the potential usefulness of child electronic security devices, were examined via a questionnaire. Data were provided by 41 volunteers, most of them from a local government office centre. The questionnaire asked for demographic data, and then for the risk of a child being abducted or lost when under the supervision of different caregivers and in different situations. The probable effectiveness of three common abductor ploys was also addressed. The questionnaire concluded with 10 questions about child electronic security devices. Respondents viewed mothers, fathers, and grandparents as equally responsible caregivers and young adults/babysitters as the least responsible. These effects diminished as the age of the children increased. The garden at home was judged to be the most secure environment for children of all ages, while an amusement park was judged the least secure environment. Children were perceived to be more at risk of an abduction when a stranger asked for physical assistance or to take them to the hospital because their parents were hurt, than when asked for directions. Furthermore, the respondents expressed a moderately strong need for child electronic security devices, and viewed parents who use them as more responsible than those who do not.

  20. Comparative studies of 111In-labeled monoclonal antibody using spacer-containing and non-spacer bifunctional chelates. 2

    International Nuclear Information System (INIS)

    Sun, Baofu

    1994-01-01

    Indium-111-labeled A7 monoclonal antibodies using two spacer-containing chelates, succinimido-EGS-DTPA (EGS-DTPA: diester spacer) and maleimido-C10-Bz-EDTA (C10-Bz-EDTA: hydrocarbon spacer) were investigated in human LS180 colon tumor bearing nude mice and were compared with two non-spacer chelates, cyclic DTPA dianhydride (cDTPAA) and isothiocyanatobenzyl-EDTA (SCN-Bz-EDTA). Compared with immunoconjugates using non-spacer chelates, immunoconjugates using spacer-containing chelates, especially C10-Bz-EDTA-A7 showed lower 111 In activity in normal organs. The radioactivity in the liver for C10-Bz-EDTA-A7 decreased continuously till 96 hrs postinjection, however, this liver radioactivity for EGS-DTPA-A7 showed little change after 24 hrs. Moreover, in liver subcellular distribution study, EGS-DTPA-A7 showed a higher activity retention in mitochondrial fraction which contained lysosome, a place for metabolizing and storing of 111 In labeled antibody, than that of C10-Bz-EDTA-A7. The C10-Bz-EDTA-A7 conjugate demonstrated more preferable tumor-to-non tumor contrast on the scintigrams than that found with other three immunoconjugates. Up to 96 hrs postinjection, tumor bearing nude mice injecting with immunoconjugates using spacer-containing chelates exreted twice radioactivity from whole body than that excreted by using non-spacer chelates. Interestingly, different from other three chelates, C10-Bz-EDTA-A7 were mainly excreted via feces. We conclude that the decrease of radioactivity in normal tissues in the case of EGS-DTPA-A7 was due to the rapid decrease of activity in the blood, while in the case of C10-Bz-EDTA-A7 it was due to the quickly excreted small metabolite through faces. 111 In labeled C10-Bz-EDTA conjugate is superior, at least when conjugated with A7, to other three chelate conjugates used in this study. (author)

  1. Shelf life of pie caps with biodegradable films as spacers

    Directory of Open Access Journals (Sweden)

    Daniela Verónica Escobar Gianni

    2013-01-01

    Full Text Available Commonly pie caps at market use polyethylene films as spacers between them. This paper studies the conventional spacers replacement with edible and biodegradable films made with whey protein isolate (WPI and potassium sorbate as a preservative. Besides facilitating the separation of pie caps, with this application is intended to increase their shelf life. The films made by the compression molding method were used as spacers in pie caps without preservative in their formula (A and with preservative (B and they were compared with conventional polyethylene spacers (C. During four months, monthly sensory, microbiological and physicochemical (humidity evaluations were done on the pie caps, together with humidity and solubility evaluations of the films. None of the samples showed microbiological or sensory deterioration. The sensory attributes showed no or slight difference in study time. Between samples the differences were minor: the best scores were for sample A in color, sample C in flavor, and samples B and C in texture and overall liking. The edible films have an interesting potential for this application, although studies in disguise the flavor of serum should be done.

  2. Ribosomal DNA internal transcribed spacer 1 and internal ...

    African Journals Online (AJOL)

    USER

    2010-07-26

    Jul 26, 2010 ... in some East Asian countries such as China, Korea and. *Corresponding author. E-mail: soonkwan@kangwon.ac.kr. Tel: +82 33 250 6476. Fax: +82 33 250 6470. Abbreviations: nrDNA, Nuclear ribosomal DNA; ITS, internal transcribed spacer; PCR, polymerase chain reaction; BLAST, basic local alignment ...

  3. Deformation behavior of cell spring of an irradiated spacer grid

    International Nuclear Information System (INIS)

    Jin, Y. G.; Baek, S. J.; Ryu, W. S.; Kim, G. S.; Yoo, B. O.; Kim, D. S.; Ahn, S. B.; Chun, Y. B.; Choo, Y. S.

    2012-01-01

    Mechanical properties of a space grid of a fuel assembly are of great importance for fuel operation reliability in extended fuel burnup and duration of fuel life. The spacer grid with inner and outer straps has cell spring and dimples, which are in contact with the fuel rod. The spacer grids supporting the fuel rods absorb vibration impacts due to the reactor coolant flow and also grid spring force is decreasing under irradiation. This reduction of contact force might cause the grid to rod fretting wear. The fretting failure of the fuel rod is one of the significant issues recently in the nuclear industry from an economical as well as a safety concern. Thus, it is important to understand the characteristics of cell spring behavior for an irradiated spacer grid. In the present study, the stiffness test and dimensional measurement of cell springs were conducted to investigate the deformation behavior of cell springs of an irradiated spacer grid in a hot cell at IMEF (irradiated materials examination facility) of KAERI

  4. Hot fuel examination facility element spacer wire-wrap machine

    International Nuclear Information System (INIS)

    Tobias, D.A.; Sherman, E.K.

    1989-01-01

    Nondestructive examinations of irradiated experimental fuel elements conducted in the Argonne National Laboratory Hot Fuel Examination Facility/North (HFEF/N) at the Idaho National Engineering Laboratory include laser and contact profilometry (element diameter measurements), electrical eddy-current testing for cladding and thermal bond defects, bow and length measurements, neutron radiography, gamma scanning, remote visual exam, and photography. Profilometry was previously restricted to spiral profilometry of the element to prevent interference with the element spacer wire wrapped in a helix about the Experimental Breeder Reactor II (EBR-II)-type fuel element from end to end. By removing the spacer wire prior to conducting profilometry examination, axial profilometry techniques may be used, which are considerably faster than spiral techniques and often result in data acquisition more important to experiment sponsors. Because the element must often be reinserted into the nuclear reactor (EBR-II) for additional irradiation, however, the spacer wire must be reinstalled on the highly irradiated fuel element by remote means after profilometry of the wireless elements. The element spacer wire-wrap machine developed at HFEF is capable of helically wrapping fuel elements with diameters up to 1.68 cm (0.660 in.) and 2.44-m (96-in.) lengths. The machine can accommodate almost any desired wire pitch length by simply inserting a new wrapper gear module

  5. Experimental Investigation on the Behavior of Bracing Damper Systems by Utilizing Metallic Yielding and Recentering Material Devices

    Directory of Open Access Journals (Sweden)

    Jong Wan Hu

    2018-01-01

    Full Text Available With the aim of effectively reducing the structural damage caused by earthquake events, bracing systems equipped with retrofitting damper devices, which take advantage of the energy dissipation and impact absorption, have been widely used in practical construction sites. These bracing dampers, however, have been recognized as expendable supplies for easily replacing the damaged ones after a strong earthquake because they are commonly designed to undergo concentrated force and deformation for the purpose of protecting the main structural members such as the columns and beams. In this paper, the use of new superelastic shape memory alloy (SMA dampers that can partially recover their original configuration is proposed to decrease the repair cost. In addition, the conventional steel dampers used for improving the energy dissipation arising due to metallic yielding are additionally integrated into the bracing member. The behaviors of such bracing systems with the damper devices were reproduced in experimental tests with the cyclic loading history, and then their strength capacity and recentering capability were estimated based on the experiment results. Finally, additional experimental tests were performed by imposing cyclic loading histories with different loading speeds on the superelastic SMA and steel plate damper specimens.

  6. Utility of Ochrobactrum anthropi YC152 in a Microbial Fuel Cell as an Early Warning Device for Hexavalent Chromium Determination

    Directory of Open Access Journals (Sweden)

    Guey-Horng Wang

    2016-08-01

    Full Text Available Fast hexavalent chromium (Cr(VI determination is important for environmental risk and health-related considerations. We used a microbial fuel cell-based biosensor inoculated with a facultatively anaerobic, Cr(VI-reducing, and exoelectrogenic Ochrobactrum anthropi YC152 to determine the Cr(VI concentration in water. The results indicated that O. anthropi YC152 exhibited high adaptability to pH, temperature, salinity, and water quality under anaerobic conditions. The stable performance of the microbial fuel cell (MFC-based biosensor indicated its potential as a reliable biosensor system. The MFC voltage decreased as the Cr(VI concentration in the MFC increased. Two satisfactory linear relationships were observed between the Cr(VI concentration and voltage output for various Cr(VI concentration ranges (0.0125–0.3 mg/L and 0.3–5 mg/L. The MFC biosensor is a simple device that can accurately measure Cr(VI concentrations in drinking water, groundwater, and electroplating wastewater in 45 min with low deviations (<10%. The use of the biosensor can help in preventing the violation of effluent regulations and the maximum allowable concentration of Cr(VI in water. Thus, the developed MFC biosensor has potential as an early warning detection device for Cr(VI determination even if O. anthropi YC152 is a possible opportunistic pathogen.

  7. On the impact analysis of a PWR spacer grid

    International Nuclear Information System (INIS)

    Song, Kee Nam; Lee, S. H.

    2012-01-01

    A spacer grid, which is an interconnected array of slotted grid straps and is welded at the intersections to form an egg crate structure, is one of the most important structural components in a PWR fuel assembly. From a structural point of view, the spacer grid is required to have sufficient crush strength under lateral loads so that nuclear fuel rods are maintained in a cool able geometry, and that control rods can be inserted. The capacity of a spacer grid to resist lateral loads is usually characterized in terms of its crush strength, and it was reported that the lateral crush strength of the spacer grid is closely related with welding quality of the spacer grid. Microstructures in the weld zone, including a heat affected zone (HAZ), are different from that in a parent material. Consequently, the mechanical properties in the weld zone are different from those in the parent material to some extent. When a welded structure is loaded, the mechanical behavior of the welded structure might be different from the case of a structure with homogeneous mechanical properties. Nonetheless, mechanical properties in the welded structure have been neglected in many structural analyses of the spacer grid due to a lack of mechanical properties in the weld zone. When the weld zone is very narrow and the interfaces are not clear, it is difficult to take tensile test specimens in the weld zone. The reason for this is that the mechanical properties in the parent material are usually used in the structural analyses in the welded structure. As an aside, it has been recently determined that the ball indentation technique has the potential to be an excellent substitute for a standard tensile test, particularly in the case of small specimens or property gradient materials such as welds. In this study, to investigate the effect on the mechanical behavior of the spacer grid when using weld mechanical properties, strength analyses considering the weld mechanical properties recently obtained

  8. Effect of spacer grids on CHF in tube bundles

    International Nuclear Information System (INIS)

    Jayanti, Sreenivas; Valette, Michel

    2004-01-01

    Spacers grids are used to support tube bundles in steam generators and in nuclear reactor fuel assemblies. These grids interface with the flow and heat transfer in a number of ways and their effect has been studied by a number of researchers. It is known that generally they have a beneficial effect on critical heat flux (CHF) in typical nuclear reactor assemblies. However, the enhancement obtained depends on the geometric characteristics of the spacer grids as well as on the parameter range in terms of pressure, local mass velocity and quality. In the present study, the problem is approached in the context of a one-dimensional three-field model. Unlike in previous approaches, no specific modeling of the constitutive laws is made to account for spacer effects and only the geometric details such as the reduction in the cross-sectional area and the hydraulic diameter are included in the calculation which is otherwise the same as that for flow through a single tube. It is shown by comparison with literature data that this approach leads to satisfactory prediction of the thermal-hydraulic effects of spacers and that the beneficial effects of spacers on dry out can be manifested only when the entrainment rate is neither too high nor too low. Their effect on reducing the post-dry out wall temperature is also limited to certain cases. The present work has been performed as part of the EDF-CEA Neptune project also supported by the Institut de Radioprotection et de Surete Nucleaire (IRSN, France) and FRAMATOME-ANP. NEPTUNE is a new set of two phase thermalhydraulic computer codes devoted to safety analysis of nuclear power plants. (author)

  9. Biofouling Control in Spiral-Wound Membrane Systems: Impact of Feed Spacer Modification and Biocides

    KAUST Repository

    Siddiqui, Amber

    2016-01-01

    was developed. The combination of modeling and experimental testing of 3D printed spacers is a promising strategy to develop advanced spacers aiming to reduce the impact of biofilm formation on membrane performance and to improve the cleanability of spiral

  10. Impact of feed spacer and membrane modification by hydrophilic, bactericidal and biocidal coating on biofouling control

    KAUST Repository

    Araú jo, Paula A.; Miller, Daniel J.; Correia, Patrí cia B.; van Loosdrecht, Mark C.M.; Kruithof, Joop C.; Freeman, Benny Dean; Paul, Donald; Vrouwenvelder, Johannes S.

    2012-01-01

    surface modification agents expected to resist protein and bacterial adhesion, while copper feed spacer coatings and biocides infused in feed spacers are expected to restrict biological growth. Our studies showed that polydopamine and polydopamine-. g

  11. Development and characterization of 3D-printed feed spacers for spiral wound membrane systems

    KAUST Repository

    Siddiqui, Amber; Farhat, Nadia; Bucs, Szilard; Valladares Linares, Rodrigo; Picioreanu, Cristian; Kruithof, Joop C.; van Loosdrecht, Mark C.M.; Kidwell, James; Vrouwenvelder, Johannes S.

    2016-01-01

    suggested that the impact of spacers on hydraulics and biofouling can be improved. A good agreement was found for the modeled and measured relationship between linear flow velocity and pressure drop for feed spacers with the same geometry, indicating

  12. On the Origin of Reverse Transcriptase-Using CRISPR-Cas Systems and Their Hyperdiverse, Enigmatic Spacer Repertoires.

    Science.gov (United States)

    Silas, Sukrit; Makarova, Kira S; Shmakov, Sergey; Páez-Espino, David; Mohr, Georg; Liu, Yi; Davison, Michelle; Roux, Simon; Krishnamurthy, Siddharth R; Fu, Becky Xu Hua; Hansen, Loren L; Wang, David; Sullivan, Matthew B; Millard, Andrew; Clokie, Martha R; Bhaya, Devaki; Lambowitz, Alan M; Kyrpides, Nikos C; Koonin, Eugene V; Fire, Andrew Z

    2017-07-11

    analysis of available bacterial sequence data, we find evidence that RT-based RNA adaptation machinery has been able to join with CRISPR-Cas immune systems in many, diverse bacterial species. To investigate whether the abilities to adapt to DNA and RNA molecules are utilized for defense against distinct classes of invaders in nature, we sequenced CRISPR arrays from samples of commercial-scale open-air cultures of Arthrospira platensis , a cyanobacterium that contains both RT-lacking and RT-containing CRISPR-Cas systems. We uncovered a diverse pool of naturally occurring immune memories, with the RT-lacking locus acquiring a number of segments matching known viral or bacterial genes, while the RT-containing locus has acquired spacers from a distinct sequence pool for which the source remains enigmatic. Copyright © 2017 Silas et al.

  13. COMPETITION BEETWEN DYNAMIC RECUPERATION AND RECRYSTALLIZATION OF ASTM F 138 AUSTENITIC STAINLESS STEEL UTILIZED IN MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    Fabio Henrique Casarini Geronimo

    2013-06-01

    Full Text Available ASTM F 138 austenitic stainless steel has being used in the manufacture of orthopedical devices by hot forging. In this work, the flow stress curves are determined by hot torsion tests in a wide range of temperatures and strain rates. With the observed microestrutural evolution by optical microscopy in different hot forming conditions in addiction with EBSD (Electron Backscatter Diffraction techniques it is possible to obtained the recrystallized volume fraction and the misorientation angles of the samples. Due to the intermediate level of stacking fault energy of this material, during the dynamic softening occurs a competition between recrystallization and recovery. The aim of this work is to identify the softening mechanisms in this stainless steel, as well as in which hot work conditions they become more active.

  14. Effect of GFRP spacer on local deformation of large superconductor in coil pack

    International Nuclear Information System (INIS)

    Nishimura, Arata; Tamura, Hitoshi; Mito, Toshiyuki; Yamamoto, Junya

    1994-01-01

    Design and construction of the Large Helical Device (LHD) are in progress at the National Institute for Fusion Science (NIFS) in Japan. The LHD has superconducting poloidal and helical coils, and many efforts have been undertaken to develop these large superconductors. When designing a large superconducting magnet, the mechanical behavior of the wound structure becomes a very important factor since the apparent rigidity affects the design of a coil support structure and the superconducting coil needs to endure the large electro-magnetic force it creates. Also, non-linear mechanical behavior should yield the instability of the magnet. In this paper, local deformation in a large conductor caused by GFRP spacers and epoxy adhesives was investigated after compressive rigidity testing. The epoxy adhesive used for attaching the GFRP spacers to the superconductor changed shape from an almost square sheet into a lens-like sheet during deformation, and a dent appeared on the surface of the superconductor. Three-dimensional FEM analysis showed that a compressive stress in the vertical direction of the loading axis existed in the adhesive plane. This stress component makes the adhesive lens-like and it results in the dent created during the compressive testing. This local deformation should yield a part of the permanent deformation observed after the compressive load cycle at 4.2 K

  15. Influence of the spacer layer on microstructure and magnetic properties of [NdFeB/(NbCu)]xn thin films

    Energy Technology Data Exchange (ETDEWEB)

    Chiriac, H. [National Institute of R and D for Technical Physics, 47 Mangeron Blvd., 700050 Iasi (Romania); Grigoras, M. [National Institute of R and D for Technical Physics, 47 Mangeron Blvd., 700050 Iasi (Romania); Urse, M. [National Institute of R and D for Technical Physics, 47 Mangeron Blvd., 700050 Iasi (Romania)]. E-mail: urse@phys-iasi.ro

    2007-09-15

    Some results concerning the influence of the composition and thickness of NbCu spacer layer on the microstructure and magnetic properties of multilayer [NdFeB/(NbCu)]xn films, in view of their utilization for manufacturing the thin film permanent magnets are presented. A comparison between the microstructure and magnetic properties of NdFeB single layer and [NdFeB/(NbCu)]xn multilayer is also presented. The multilayer [NdFeB/(NbCu)]xn thin films with the thickness of the NdFeB layer of 180nm and the thickness of the NbCu spacer layer of 3nm, exhibit good hard magnetic characteristics such as coercive force H{sub c} of about 1510kA/m and the remanence ratio M{sub r}/M{sub s} of about 0.8.

  16. Influence of the spacer layer on microstructure and magnetic properties of [NdFeB/(NbCu)]xn thin films

    International Nuclear Information System (INIS)

    Chiriac, H.; Grigoras, M.; Urse, M.

    2007-01-01

    Some results concerning the influence of the composition and thickness of NbCu spacer layer on the microstructure and magnetic properties of multilayer [NdFeB/(NbCu)]xn films, in view of their utilization for manufacturing the thin film permanent magnets are presented. A comparison between the microstructure and magnetic properties of NdFeB single layer and [NdFeB/(NbCu)]xn multilayer is also presented. The multilayer [NdFeB/(NbCu)]xn thin films with the thickness of the NdFeB layer of 180nm and the thickness of the NbCu spacer layer of 3nm, exhibit good hard magnetic characteristics such as coercive force H c of about 1510kA/m and the remanence ratio M r /M s of about 0.8

  17. Viability of permanent PMMA spacer with combined free fasciocutaneous tissue transfer for failed charcot reconstruction: A 38 month prospective case report

    Directory of Open Access Journals (Sweden)

    Tammer Elmarsafi

    Full Text Available Introduction: Charcot Neuroarthropathy is a complex lower extremity pathology which predisposes the afflicted limb to ulcerations, osteomyelitis, and risk of major amputation. Charcot Neuroarthropathy often requires osseous reconstruction, which can be complicated with osteomyelitis and hardware infection. When soft tissue and osseous deficits must be concomitantly addressed, the use of PMMA spacers can be combined with free tissue transfers. Presentation of case: 71 year old Caucasian male with Diabetic Charcot Neuroarthopathy underwent osseous reconstruction with internal hardware. The surgical site was complicated by acute infection, osteomyelitis, exposed hardware requiring removal, and multiple surgical débridement. The degree of soft tissue and osseous deficit post-débridement required complex reconstruction. Discussion: The osseous deficit was addressed with the use of a permanent PMMA cement spacer. The soft tissue deficit was reconstructed with a free tissue transfer. This case report demonstrates the long term viability and utility of the use of permanent cement spacers when combined with free tissue transfer for closure of complex diabetic foot wounds. This case is an example of a multidisciplinary team approach to limb salvage with successful long term outcome; a plantigrade stable functional foot in an ambulatory highly active patient. Follow up time since initial intervention was 38 months. Conclusion: The use of a permanent PMMA cement spacer does not preclude free tissue transfer in complex host lower extremity reconstruction. A multidisciplinary team approach is a vital component to successful salvage outcomes. Keywords: Diabetes, Charcot neuroarthropathy, Ulcer, Cement spacer, Free tissue transfer, Osteomyelitis

  18. Biofouling Control in Spiral-Wound Membrane Systems: Impact of Feed Spacer Modification and Biocides

    KAUST Repository

    Siddiqui, Amber

    2016-12-01

    High-quality drinking water can be produced with membrane-based filtration processes like reverse osmosis and nanofiltration. One of the major problems in these membrane systems is biofouling that reduces the membrane performance, increasing operational costs. Current biofouling control strategies such as pre-treatment, membrane modification, and chemical cleaning are not sufficient in all cases. Feed spacers are thin (0.8 mm), complex geometry meshes that separate membranes in a module. The main objective of this research was to evaluate whether feed spacer modification is a suitable strategy to control biofouling. Membrane fouling simulator studies with six feed spacers showed differences in biofouled spacer performance, concluding that (i) spacer geometry influences biofouling impact and (ii) biofouling studies are essential for evaluation of spacer biofouling impact. Computed tomography (CT) was found as a suitable technique to obtain three-dimensional (3D) measurements of spacers, enabling more representative mathematical modeling of hydraulic behavior of spacers in membrane systems. A strategy for developing, characterizing, and testing of spacers by numerical modeling, 3D printing of spacers and experimental membrane fouling simulator studies was developed. The combination of modeling and experimental testing of 3D printed spacers is a promising strategy to develop advanced spacers aiming to reduce the impact of biofilm formation on membrane performance and to improve the cleanability of spiral-wound membrane systems.

  19. Utilization of a biomedical device (VeinViewer® ) to assist with peripheral intravenous catheter (PIV) insertion for pediatric nurses.

    Science.gov (United States)

    McNeely, Heidi L; Ream, Theresa L; Thrasher, Jodi M; Dziadkowiec, Oliwier; Callahan, Tiffany J

    2018-04-01

    Vascular access in pediatric patients can be challenging even with the currently available technological resources. This nurse-driven research study explored time, cost, and resources for intravenous access to determine if a biomedical device, VeinViewer ® Vision, would facilitate improvements in pediatric access. In addition, this study looked at nurse perceptions of skills and confidence around intravenous insertion and if the use of the VeinViewer ® impacted these perceptions. Literature examining pediatric intravenous access success rates compared with nurse perceived skills and confidence is lacking. Nonblinded randomized control trial of pediatric nurses working in an acute care hospital setting. A preliminary needs assessment solicited feedback from nurses regarding their practice, perceived skills, and confidence with placing peripheral intravenous catheters (PIVs). Due to the results of the preliminary needs assessment, a research study was designed and 40 nurses were recruited to participate. The nurses were randomized into either a VeinViewer ® or standard practice group. Nurse participants placed intravenous catheters on hospitalized pediatric patients using established procedures while tracking data for the study. Needs assessment showed a majority of nurses felt a biomedical device would be helpful in building their intravenous insertion skills and their confidence. The study results did not demonstrate any clinically significant differences between VeinViewer ® use and standard practice for intravenous catheter insertion in pediatric patients for success of placement, number of attempts, or overall cost. In addition, no difference was noted between nurses in either group on perceived skills or confidence with insertion of PIVs. The ongoing need for resources focused on building nurse skills and confidence for PIV insertion was highlighted and organizations should continue to direct efforts toward developing skills and competency for staff that

  20. Luminescence mechanisms of organic/inorganic hybrid organic light-emitting devices fabricated utilizing a Zn2SiO4:Mn color-conversion layer

    International Nuclear Information System (INIS)

    Choo, D.C.; Ahn, S.D.; Jung, H.S.; Kim, T.W.; Lee, J.Y.; Park, J.H.; Kwon, M.S.

    2010-01-01

    Zn 2 SiO 4 :Mn phosphor layers used in this study were synthesized by using the sol-gel method and printed on the glass substrates by using a vehicle solution and a heating process. Organic/inorganic hybrid organic light-emitting devices (OLEDs) utilizing a Zn 2 SiO 4 :Mn color-conversion layer were fabricated. X-ray diffraction data for the synthesized Zn 2 SiO 4 :Mn phosphor films showed that the Zn ions in the phosphor were substituted into Mn ions. The electroluminescence (EL) spectrum of the deep blue OLEDs showed that a dominant peak at 461 nm appeared. The photoluminescence spectrum for the Zn 2 SiO 4 :Mn phosphor layer by using a 470 nm excitation source showed that a dominant peak at 527 nm appeared, which originated from the 4 T 1 - 6 A 1 transitions of Mn ions. The appearance of the peak around 527 nm of the EL spectra for the OLEDs fabricated utilizing a Zn 2 SiO 4 :Mn phosphor layer demonstrated that the emitted blue color from the deep blue OLEDs was converted into a green color due to the existence of the color-conversion layer. The luminescence mechanisms of organic/inorganic hybrid OLEDs fabricated utilizing a Zn 2 SiO 4 :Mn color-conversion layer are described on the basis of the EL and PL spectra.

  1. High efficiency, quasi-instantaneous steam expansion device utilizing fossil or nuclear fuel as the heat source

    International Nuclear Information System (INIS)

    Claudio Filippone

    1999-01-01

    Thermal-hydraulic analysis of a specially designed steam expansion device (heat cavity) was performed to prove the feasibility of steam expansions at elevated rates for power generation with higher efficiency. The steam expansion process inside the heat cavity greatly depends on the gap within which the steam expands and accelerates. This system can be seen as a miniaturized boiler integrated inside the expander where steam (or the proper fluid) is generated almost instantaneously prior to its expansion in the work-producing unit. Relatively cold water is pulsed inside the heat cavity, where the heat transferred causes the water to flash to steam, thereby increasing its specific volume by a large factor. The gap inside the heat cavity forms a special nozzle-shaped system in which the fluid expands rapidly, accelerating toward the system outlet. The expansion phenomenon is the cause of ever-increasing fluid speed inside the cavity system, eliminating the need for moving parts (pumps, valves, etc.). In fact, the subsequent velocity induced by the sudden fluid expansion causes turbulent conditions, forcing accelerating Reynolds and Nusselt numbers which, in turn, increase the convective heat transfer coefficient. When the combustion of fossil fuels constitutes the heat source, the heat cavity concept can be applied directly inside the stator of conventional turbines, thereby greatly increasing the overall system efficiency

  2. Impact analysis of the spacer grid assembly and shape optimization of the attached spring

    Energy Technology Data Exchange (ETDEWEB)

    Park, K. J.; Lee, Z. N. [Hanyang University, Seoul (Korea)

    2002-04-01

    Spacer grids support fuel rods and maintain geometry from external impact loads. A simulation is performed for the strength of a spacer grid under the impact load. The critical impact load that leads to plastic deformation is identified by a free-fall test. A finite element model is established for the nonlinear simulation of the impact process. The simulation model is tuned based on the free-fall test. The model considers the aspects of welding and the contacts between components. Nonlinear finite element analysis is carried out using a software system called ABAQUS/EXPLICIT. The results are discussed from a design viewpoint. Design requirements are defined and a design process is established. The design process includes mathematical optimization as well as practical design method. The shape of the grid spring is designed to maintain its function during the lifetime of the fuel assembly. A structural optimization method is employed for the shape design. A good design is found. Commercial codes are utilized for structural analysis and optimization. 18 refs., 61 figs., 3 tabs. (Author)

  3. Cochlear implantation in the world's largest medical device market: utilization and awareness of cochlear implants in the United States.

    Science.gov (United States)

    Sorkin, Donna L

    2013-03-01

    Provision of cochlear implants (CIs) for those within the criteria for implantation remains lower in the United States than in some other developed nations. When adults and children are grouped together, the rate of utilization/provision remains low at around 6%. For children, the provision rate is about 50% of those who could benefit from an implant, compared with figures of about 90% for the Flanders part of Belgium, the United Kingdom and other European countries. The probable reasons for this underprovision include: low awareness of the benefits of CIs among the population; low awareness among health-care professionals; the lack of specific referral pathways; some political issues relating to the Deaf Community; and financial issues related to health provision. Such financial issues result in situations which either fail to provide for access to implants or provide too low a level of the necessary funding, especially for low-income individuals covered by public health-care programs such as Medicaid. These issues might be mitigated by adoption and publication of standards for best clinical practices for CI provision, availability of current cost-effectiveness data, and the existence of an organization dedicated to cochlear implantation. Such an organization, the American Cochlear Implant Alliance (ACI Alliance), was recently organized and is described in the paper by Niparko et al. in this Supplement.

  4. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  5. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  6. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  7. Nasal inhalation of budesonide from a spacer in children with perennial rhinitis and asthma

    DEFF Research Database (Denmark)

    Pedersen, W; Hjuler, Inga Merete; Bisgaard, H

    1998-01-01

    and asthma inhaled budesonide through the nose from a pressurized aerosol, attached to a spacer device, in a double-blind, placebo-controlled, crossover study. Compared with placebo, budesonide treatment resulted in a significant reduction of nasal symptoms (Pasthma symptoms (P...The standard treatment of allergic rhinitis and asthma consists of topical corticosteroids administered intranasally and inhaled through the mouth. Although this therapy is highly effective, and side-effects are few and mild, it may be possible further to improve the therapeutic index and patient...... compliance with the treatment. In the present study, we evaluated a nasal inhalation system used for the simultaneous treatment of rhinitis and asthma. In principle, it results in an airway deposition of the corticosteroid similar to that of inhaled allergens. Twenty-four children with perennial rhinitis...

  8. An insulating grid spacer for large-area MICROMEGAS chambers

    International Nuclear Information System (INIS)

    Bernard, D.; Delagrange, H.; D'Enterria, D.G.; Guay, M.L.M. Le; Martinez, G.; Mora, M.J.; Pichot, P.; Roy, D.; Schutz, Y.; Gandi, A.; Oliveira, R. de

    2002-01-01

    We present a novel design for large-area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mesh and the anode-pad plane, which provides a uniform 200 μm amplification gap. The uniformity of the amplification gap thickness has been verified. The gain performances of the detector are presented and compared to the values obtained with detectors using cylindrical micro spacers. The new design presents several technical and financial advantages

  9. Successful implementation of spacer treatment guideline for acute asthma

    OpenAIRE

    Powell, C; Maskell, G; Marks, M; South, M; Robertson, C; LENNEY, W.

    2001-01-01

    AIMS—To develop and implement an evidence based guideline for the treatment of acute asthma using a metered dose inhaler and spacer combination.
METHODS—Defined strategies were used for the development and implementation of a guideline, assessed by a prospective, descriptive, study using notes review, and patient, nursing, and medical staff telephone contact. The setting was a tertiary referral hospital in Victoria, Australia with 25 000 yearly admissions, and asthma acco...

  10. Bimetallic spacer means for a nuclear fuel assembly

    International Nuclear Information System (INIS)

    Anthony, A.J.

    1981-01-01

    A bimetallic spacer means designed to be cooperatively associated with a nuclear fuel assembly and operative to resist the occurrence of in-reactor bowing of the nuclear fuel assembly. The subject bimetallic spacer means in accord with one embodiment of the invention includes a member formed, at least principally, of Zircaloy to which are attached a plurality of stainless steel strips. The latter stainless steel strips are located on the external surface of the Zircaloy member and with the major axis of each of the plurality of stainless steel strips extending substantially perpendicular to the major axis of the Zircaloy member. In accord with another embodiment of the invention, the subject bimetallic spacer means includes a member formed at least principally of Zircaloy to which a plurality of stainless steel strips are attached so as to be positioned thereon externally thereof and with the major axis of each of the plurality of stainless steel strips extending substantially parallel to the major axis of the Zircaloy member. In accord with a further embodiment of the invention, the stainless steel strips are attached to preselected members, each embodying at least a cladding of Zircaloy, which are located in the rows of fuel rods that define the perimeter of the fuel matrix of the nuclear fuel assembly. In each of the embodiments, the stainless steel strips during power production expand outwardly to a greater extent than do the members to which the stainless steel strips are attached, thereby forming stiff springs which abut against like bimetallic spacer means with which the other nuclear fuel assemblies are provided in a given nuclear reactor core to thus prevent the occurrence of in-reactor bowing of the nuclear fuel assemblies. Namely, the stainless steel strips expand laterally relative to the fuel assembly and thereby occupy the space adjacent to the external surface of the fuel assembly

  11. Optically-powered Voltage-supply-device for Effective Utilization of Optical Energy in the Fiber-To-The-Home Network

    Science.gov (United States)

    Fukano, Hideki; Shinagawa, Takeshi; Tsuruta, Kenji

    An optically powered device with using InGaAs-Photodiode has been developed. This study aims to harvest light energy (2.8∼500μW) from the FTTH (Fiber To The Home) network and to utilize it for operating remote sensors without external energy sources. First, we designed and evaluated the characteristics of the booster circuit and confirmed that it could boost an input voltage of 0.3 V to 3.0 V. Next, we also evaluated the characteristics of InGaAs photodiode and confirmed that it can output a voltage over 0.3 V at 10-μW input light. We demonstrate that a ready-made sensor can be operated with an input optical power as low as 10 μW.

  12. Using medical imaging for the detection of adverse events ("incidents") during the utilization of left ventricular assist devices in adult patients with advanced heart failure.

    Science.gov (United States)

    Kaufmann, Friedrich; Krabatsch, Thomas

    2016-05-01

    Ventricular assist devices (VAD) are used for mechanical support of the terminally failing heart. Failure of these life supporting systems can be fatal. Early and reliable detection of any upcoming problems is mandatory and is crucial for the outcome. Medical imaging methods are described within this review, which are not only essential for diagnosis of typically VAD-related complications but also for the detection or verification of technical issues. Within this review the utilization of medical imaging equipment for the diagnosis of technical malfunctions or damages of implanted system components is discussed. A newly developed specialized acoustic imaging method for pump thrombosis detection will also be described along with the most common VAD-related medical complications and their respective imaging methods and the limitations induced by the use of the VAD-system.

  13. The utility of an electronic adherence assessment device in type 2 diabetes mellitus: a pilot study of single medication

    Directory of Open Access Journals (Sweden)

    Nadir Kheir

    2010-07-01

    Full Text Available Nadir Kheir1, William Greer2, Adil Yousif3, Hajer Al-Geed1, Randa Al Okkah1, Mahmoud Zirie4, Amy Sandridge5, Manal Zaidan61College of Pharmacy, 2Sidra Medical and Research Centre, 3Department of Statistics, College of Arts and Sciences, Qatar University, 4Hamad General Hospital, Hamad Medical Corporation, Doha, Qatar; 5Private Research Consultant, 6Al Amal Cancer Centre, Hamad Medical Corporation, Doha, QatarObjectives: The primary objective of this pilot study was to determine if the Medication Event Monitoring System (MEMS is capable of providing meaningful estimates of compliance within the indigenous Qatari population. The secondary objective was to highlight any specific problems which might be associated with the use of MEMS within this population.Method: A sample of adult diabetic Qatari patients attending an outpatient diabetic clinic were administered a Knowledge, Attitude, and Practices (KAP questionnaire and then dispensed one of their regular medications in a MEMS®-fitted bottle. Data contained in the MEMS® were downloaded after the patients returned for a refill and adherence was estimated using 2 methods: pill count and MEMS® data.Results: A total of 54 patients agreed to participate in this pilot study. Adherence to daily doses was 67.7% and with regimen 13.7%. No correlation was found between adherence assessed by pill count and MEMS®. The association between KAP and adherence was generally poor. A number of other issues and challenges in the use of MEMS® that could affect its utility were noted and will be discussed.Conclusions: Our results revealed problems associated with the use of MEMS® that could affect its usefulness in assessing adherence in this part of the world. Some issues identified in this pilot study included retrieving the MEMS®, registering extra opening of MEMS®, desire to hoard medicine by taking doses at different frequency than recorded in MEMS®. All these issues could be closely associated with the

  14. Impact of feed spacer and membrane modification by hydrophilic, bactericidal and biocidal coating on biofouling control

    KAUST Repository

    Araújo, Paula A.

    2012-06-01

    The influence of polydopamine- and polydopamine-. graft-poly(ethylene glycol)-coated feed spacers and membranes, copper-coated feed spacers, and commercially-available biostatic feed spacers on biofouling has been studied in membrane fouling simulators. Feed spacers and membranes applied in practical membrane filtration systems were used; biofouling development was monitored by feed channel pressure drop increase and biomass accumulation. Polydopamine and polydopamine-. g-PEG are hydrophilic surface modification agents expected to resist protein and bacterial adhesion, while copper feed spacer coatings and biocides infused in feed spacers are expected to restrict biological growth. Our studies showed that polydopamine and polydopamine-. g-PEG coatings on feed spacers and membranes, copper coatings on feed spacers, and a commercial biostatic feed spacer did not have a significant impact on feed channel pressure drop increase and biofilm accumulation as measured by ATP and TOC content. The studied spacer and membrane modifications were not effective for biofouling control; it is doubtful that feed spacer and membrane modification, in general, may be effective for biofouling control regardless of the type of applied coating. © 2012 Elsevier B.V.

  15. Minimally invasive treatment of lumbar spinal stenosis with a novel interspinous spacer

    Directory of Open Access Journals (Sweden)

    Shabat S

    2011-09-01

    Full Text Available Shay Shabat1, Larry E Miller2,3, Jon E Block3, Reuven Gepstein11Spinal Care Unit, Sapir Medical Center, Kfar Saba, Israel; 2Miller Scientific Consulting, Inc, Biltmore Lake, NC, USA; 3Jon E Block, PhD, Inc, San Francisco, CA, USAPurpose: To assess the safety and effectiveness of a novel, minimally invasive interspinous spacer in patients with moderate lumbar spinal stenosis (LSS.Methods: A total of 53 patients (mean age, 70 ± 11 years; 45% female with intermittent neurogenic claudication secondary to moderate LSS, confirmed on imaging studies, were treated with the Superion® Interspinous Spacer (VertiFlex, Inc, San Clemente, CA and returned for follow-up visits at 6 weeks, 1 year, and 2 years. Study endpoints included axial and extremity pain severity with an 11-point numeric scale, Zurich Claudication Questionnaire (ZCQ, back function with the Oswestry Disability Index (ODI, health-related quality of life with the Physical Component Summary (PCS and Mental Component Summary (MCS scores from the SF-12, and adverse events.Results: Axial and extremity pain each decreased 54% (both P < 0.001 over the 2-year follow-up period. ZCQ symptom severity scores improved 43% (P < 0.001 and ZCQ physical function improved 44% (P < 0.001 from pre-treatment to 2 years post-treatment. A statistically significant 50% improvement (P < 0.001 also was noted in back function. PCS and MCS each improved 40% (both P < 0.001 from pre-treatment to 2 years. Clinical success rates at 2 years were 83%–89% for ZCQ subscores, 75% for ODI, 78% for PCS, and 80% for MCS. No device infection, implant breakage, migration, or pull-out was observed, although two (3.8% patients underwent explant with subsequent laminectomy.Conclusion: Moderate LSS can be effectively treated with a minimally invasive interspinous spacer. This device is appropriate for select patients who have failed nonoperative treatment measures for LSS and meet strict anatomical criteria.Keywords: Superion, axial

  16. Eddy current monitoring of spacers in coolant channel assemblies of nuclear reactor

    International Nuclear Information System (INIS)

    Bhole, V.M.; Rastogi, P.K.; Kulkarni, P.G.; Vijayaraghavan, R.

    1993-01-01

    An eddy current testing method has been standardised for monitoring spacer springs which are used in coolant channel assemblies of pressurised heavy water nuclear reactors (PHWRs). The standard bobbin coil probe used for monitoring the spacer spring detects only the location but does not monitor the tilt orientation and tilt angle of a tilted spacer spring. The knowledge of location along with the tilt orientation of the spacer spring greatly improves the performance of repositioning methods. A modified probe with angular windings has been developed in laboratory tests for monitoring the location as well as the tilt orientation of the spacer springs. Experimental results are presented showing excellent performance of the modified probe in monitoring the exact location as well as tilt orientation of a spacer spring. The modified probe has also been used successfully in the field during repositioning of spacer springs in PHWRs before commissioning. (Author)

  17. Right ventricular functional analysis utilizing first pass radionuclide angiography for pre-operative ventricular assist device planning: a multi-modality comparison.

    Science.gov (United States)

    Avery, Ryan; Day, Kevin; Jokerst, Clinton; Kazui, Toshinobu; Krupinski, Elizabeth; Khalpey, Zain

    2017-10-10

    Advanced heart failure treated with a left ventricular assist device is associated with a higher risk of right heart failure. Many advanced heart failures patients are treated with an ICD, a relative contraindication to MRI, prior to assist device placement. Given this limitation, left and right ventricular function for patients with an ICD is calculated using radionuclide angiography utilizing planar multigated acquisition (MUGA) and first pass radionuclide angiography (FPRNA), respectively. Given the availability of MRI protocols that can accommodate patients with ICDs, we have correlated the findings of ventricular functional analysis using radionuclide angiography to cardiac MRI, the reference standard for ventricle function calculation, to directly correlate calculated ejection fractions between these modalities, and to also assess agreement between available echocardiographic and hemodynamic parameters of right ventricular function. A retrospective review from January 2012 through May 2014 was performed to identify advanced heart failure patients who underwent both cardiac MRI and radionuclide angiography for ventricular functional analysis. Nine heart failure patients (8 men, 1 woman; mean age of 57.0 years) were identified. The average time between the cardiac MRI and radionuclide angiography exams was 38.9 days (range: 1 - 119 days). All patients undergoing cardiac MRI were scanned using an institutionally approved protocol for ICD with no device-related complications identified. A retrospective chart review of each patient for cardiomyopathy diagnosis, clinical follow-up, and echocardiogram and right heart catheterization performed during evaluation was also performed. The 9 patients demonstrated a mean left ventricular ejection fraction (LVEF) using cardiac MRI of 20.7% (12 - 40%). Mean LVEF using MUGA was 22.6% (12 - 49%). The mean right ventricular ejection fraction (RVEF) utilizing cardiac MRI was 28.3% (16 - 43%), and the mean RVEF calculated by

  18. Translation of First North American 50 and 70 cc Total Artificial Heart Virtual and Clinical Implantations: Utility of 3D Computed Tomography to Test Fit Devices.

    Science.gov (United States)

    Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain

    2017-08-01

    Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Development and characterization of 3D-printed feed spacers for spiral wound membrane systems

    KAUST Repository

    Siddiqui, Amber

    2016-01-02

    Feed spacers are important for the impact of biofouling on the performance of spiral-wound reverse osmosis (RO) and nanofiltration (NF) membrane systems. The objective of this study was to propose a strategy for developing, characterizing, and testing of feed spacers by numerical modeling, three-dimensional (3D) printing of feed spacers and experimental membrane fouling simulator (MFS) studies. The results of numerical modeling on the hydraulic behavior of various feed spacer geometries suggested that the impact of spacers on hydraulics and biofouling can be improved. A good agreement was found for the modeled and measured relationship between linear flow velocity and pressure drop for feed spacers with the same geometry, indicating that modeling can serve as first step in spacer characterization. An experimental comparison study of a feed spacer currently applied in practice and a 3D printed feed spacer with the same geometry showed (i) similar hydraulic behavior, (ii) similar pressure drop development with time and (iii) similar biomass accumulation during MFS biofouling studies, indicating that 3D printing technology is an alternative strategy for development of thin feed spacers with a complex geometry. Based on the numerical modeling results, a modified feed spacer with low pressure drop was selected for 3D printing. The comparison study of the feed spacer from practice and the modified geometry 3D printed feed spacer established that the 3D printed spacer had (i) a lower pressure drop during hydraulic testing, (ii) a lower pressure drop increase in time with the same accumulated biomass amount, indicating that modifying feed spacer geometries can reduce the impact of accumulated biomass on membrane performance. The combination of numerical modeling of feed spacers and experimental testing of 3D printed feed spacers is a promising strategy (rapid, low cost and representative) to develop advanced feed spacers aiming to reduce the impact of biofilm formation on

  20. Quenching Mo optical losses in CIGS solar cells by a point contacted dual-layer dielectric spacer: a 3-D optical study.

    Science.gov (United States)

    Rezaei, Nasim; Isabella, Olindo; Vroon, Zeger; Zeman, Miro

    2018-01-22

    A 3-D optical modelling was calibrated to calculate the light absorption and the total reflection of fabricated CIGS solar cells. Absorption losses at molybdenum (Mo) / CIGS interface were explained in terms of plasmonic waves. To quench these losses, we assumed the insertion of a lossless dielectric spacer between Mo and CIGS, whose optical properties were varied. We show that such a spacer with low refractive index and proper thickness can significantly reduce absorption in Mo in the long wavelength regime and improve the device's rear reflectance, thus leading to enhanced light absorption in the CIGS layer. Therefore, we optimized a realistic two-layer MgF 2 / Al 2 O 3 dielectric spacer to exploit (i) the passivation properties of ultra-thin Al 2 O 3 on the CIGS side for potential high open-circuit voltage and (ii) the low refractive index of MgF 2 on the Mo side to reduce its optical losses. Combining our realistic spacer with optically-optimized point contacts increases the implied photocurrent density of a 750 nm-thick CIGS layer by 10% for the wavelengths between 700 and 1150 nm with respect to the reference cell. The elimination of plasmonic resonances in the new structure leads to a higher electric field magnitude at the bottom of CIGS layer and justifies the improved optical performance.

  1. Quantum size effects on spin-transfer torque in a double barrier magnetic tunnel junction with a nonmagnetic-metal (semiconductor) spacer

    International Nuclear Information System (INIS)

    Daqiq, Reza; Ghobadi, Nader

    2016-01-01

    We study the quantum size effects of an MgO-based double barrier magnetic tunnel junction with a nonmagnetic-metal (DBMTJ-NM) (semiconductor (DBMTJ-SC)) spacer on the charge current and the spin-transfer torque (STT) components using non-equilibrium Green's function (NEGF) formalism. The results show oscillatory behavior due to the resonant tunneling effect depending on the structure parameters. We find that the charge current and the STT components in the DBMTJ-SC demonstrate the magnitude enhancement in comparison with the DBMTJ-NM. The bias dependence of the STT components in a DBMTJ-NM shows different behavior in comparison with spin valves and conventional MTJs. Therefore, by choosing a specific SC spacer with suitable thickness in a DBMTJ the charge current and the STT components significantly increase so that one can design a device with high STT and faster magnetization switching. - Highlights: • The quantum size effects are studied in double barrier magnetic tunnel junctions. • Spin torque (ST) components oscillate for increasing of middle spacer thicknesses. • Due to the resonant tunneling in the quantum well, oscillations have appeared. • By replacement a metal spacer with a semiconductor (ZnO) ST has increased. • The ST components vs. bias show gradually decreasing unlike spin valves or MTJs.

  2. Quantum size effects on spin-transfer torque in a double barrier magnetic tunnel junction with a nonmagnetic-metal (semiconductor) spacer

    Energy Technology Data Exchange (ETDEWEB)

    Daqiq, Reza; Ghobadi, Nader

    2016-07-15

    We study the quantum size effects of an MgO-based double barrier magnetic tunnel junction with a nonmagnetic-metal (DBMTJ-NM) (semiconductor (DBMTJ-SC)) spacer on the charge current and the spin-transfer torque (STT) components using non-equilibrium Green's function (NEGF) formalism. The results show oscillatory behavior due to the resonant tunneling effect depending on the structure parameters. We find that the charge current and the STT components in the DBMTJ-SC demonstrate the magnitude enhancement in comparison with the DBMTJ-NM. The bias dependence of the STT components in a DBMTJ-NM shows different behavior in comparison with spin valves and conventional MTJs. Therefore, by choosing a specific SC spacer with suitable thickness in a DBMTJ the charge current and the STT components significantly increase so that one can design a device with high STT and faster magnetization switching. - Highlights: • The quantum size effects are studied in double barrier magnetic tunnel junctions. • Spin torque (ST) components oscillate for increasing of middle spacer thicknesses. • Due to the resonant tunneling in the quantum well, oscillations have appeared. • By replacement a metal spacer with a semiconductor (ZnO) ST has increased. • The ST components vs. bias show gradually decreasing unlike spin valves or MTJs.

  3. An insulating grid spacer for large-area MICROMEGAS chambers

    CERN Document Server

    Bernard, D; D'Enterria, D G; Le Guay, M; Martínez, G; Mora, M J; Pichot, P; Roy, D; Schutz, Y; Gandi, A; De Oliveira, R

    2002-01-01

    We present an original design for large area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mesh and the anode-pad plane, which provides an uniform 200 $\\mu$m amplification gap. The uniformity of the amplification gap thickness has been verified under several experimental conditions. The gain performances of the detector are presented and compared to the values obtained with detectors using cylindrical micro spacers. The new design presents several technical and financial advantages.

  4. Spacer grid with mixing blades for nuclear fuel assembly

    International Nuclear Information System (INIS)

    Noailly, J.

    1986-01-01

    The spacer grid for nuclear fuel assembly has two sets of intersecting metal plates provided with blades and defining cells. The plates are fitted only with half-blades associated with a single grid opening. The half-blades of adjacent cells are arranged at 90deg C to each other and each plate has at most one half-blade at each corner of a cell. The invention concerns fuel assemblies of pressurized water reactors. The blades arranged on a single side of the plate provide a good hydraulic uniformity. The invention provides a uniform distribution of blades (and thus of absorbing material in each hydraulic cell) [fr

  5. Tube spacer grid for a heat-exchanger tube bundle

    International Nuclear Information System (INIS)

    Scheidl, H.

    1976-01-01

    A tube spacer grid for a heat-exchanger tube bundle is formed by an annular grid frame having a groove formed in its inner surface in which the interspaced grid bars have their ends positioned and held in interspaced relationship by short sections of tubes passed through holes axially formed in the grid frame so that the tubes are positioned between the ends of the grid bars in the grooves. The tube sections may be cut from the same tubes used to form the tube bundle. 5 claims, 3 drawing figures

  6. FY1998 report on a survey related to joint utilization of welfare device development data using an international network; 1998 nendo kokusai network ni yoru fukushi kiki kaihatsu data no kyodo riyo ni kansuru chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    A survey was made in relation with joint utilization of welfare device development data using an international network. Developing welfare devices requires data from ergonomic and medical systems, while the cope of the objects is wide, and the kinds are various. For proliferation of welfare devices, system compatibility evaluation including that on using environment is important, including living environments that are different by countries. The present survey has identified how data for aged, handicapped and help-needing persons are accumulated and utilized in research organizations in America and Europe for both of the ergonomic and medical areas. The survey also investigated major academic societies in overseas countries, and collected database and academic network information that support the advanced research and development. At the same time, investigations were also made on organizations and corporations who are moving forward the efficient data utilization. Welfare device and service information providing systems in Japan were investigated to compare them with the trends in other countries. Conceptions and methods were compiled to utilize data internationally and jointly. Database models for device development were considered, and a proposal was made on structuring a research and development supporting database, and the operation method thereof. (NEDO)

  7. In vitro microbiologic evaluation of PTFE and cotton as spacer materials.

    Science.gov (United States)

    Paranjpe, Avina; Jain, Sumita; Alibhai, Karim J; Wadhwani, Chandur P; Darveau, Richard P; Johnson, James D

    2012-09-01

    To microbiologically evaluate the efficacy of cotton and polytetrafluoroethylene (PTFE) tape used as spacer materials. Twenty-six extracted human molars were restored using either cotton or PTFE tape as spacers under a standardized provisional restorative material (Cavit). The teeth were incubated for 7 days in a culture of Streptococcus gordonii or in liquid media alone. The spacers were removed and tested for bacterial contamination. The access cavities were also evaluated for bacterial contamination. Nine of 10 teeth with cotton spacers and one of 10 teeth with PTFE spacers were positive for S gordonii growth. The nine teeth in the cotton group also showed contamination of the access cavities. Even under optimal conditions, cotton spacers may cause leakage into the access cavities. Cotton fibers may serve as a route for bacterial contamination of the access cavities and root canal space. In contrast, PTFE tape did not provide an avenue for bacterial contamination.

  8. A technical report on the evaluation of the integrity for the TIG welded spacer grid

    International Nuclear Information System (INIS)

    Song, Kee Nam; Yoo, Ho Sik; Lww, Chang Woo

    1994-07-01

    The spacer grid, which supports fuel rods, guide thimble and instrumentation tube, is classified into two types according to their strap material,.ie. inconel and zircaloy spacer grid. KOFA fuel of 14 x 14 and 17 x 17 type has seven and eight spacer grid respectively. Zircaloy spacer grid is assembled by straps whose cross points are welded by TIG welding method. This technical report provides to give some information about structure and function of the spacer grid and the basis and characteristic of the TIG welding method. A series of test which is conducted to evaluate the integrity of TIG welded zircaloy spacer grid and their results have been also studied. (Author) 18 refs., 23 figs., 3 tabs

  9. A technical report on the evaluation of the integrity for the TIG welded spacer grid

    Energy Technology Data Exchange (ETDEWEB)

    Song, Kee Nam; Yoo, Ho Sik; Lww, Chang Woo [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-07-01

    The spacer grid, which supports fuel rods, guide thimble and instrumentation tube, is classified into two types according to their strap material,.ie. inconel and zircaloy spacer grid. KOFA fuel of 14 x 14 and 17 x 17 type has seven and eight spacer grid respectively. Zircaloy spacer grid is assembled by straps whose cross points are welded by TIG welding method. This technical report provides to give some information about structure and function of the spacer grid and the basis and characteristic of the TIG welding method. A series of test which is conducted to evaluate the integrity of TIG welded zircaloy spacer grid and their results have been also studied. (Author) 18 refs., 23 figs., 3 tabs.

  10. Transcriptional regulator-mediated activation of adaptation genes triggers CRISPR de novo spacer acquisition

    DEFF Research Database (Denmark)

    Liu, Tao; Li, Yingjun; Wang, Xiaodi

    2015-01-01

    Acquisition of de novo spacer sequences confers CRISPR-Cas with a memory to defend against invading genetic elements. However, the mechanism of regulation of CRISPR spacer acquisition remains unknown. Here we examine the transcriptional regulation of the conserved spacer acquisition genes in Type I......, it was demonstrated that the transcription level of csa1, cas1, cas2 and cas4 was significantly enhanced in a csa3a-overexpression strain and, moreover, the Csa1 and Cas1 protein levels were increased in this strain. Furthermore, we demonstrated the hyperactive uptake of unique spacers within both CRISPR loci...... in the presence of the csa3a overexpression vector. The spacer acquisition process is dependent on the CCN PAM sequence and protospacer selection is random and non-directional. These results suggested a regulation mechanism of CRISPR spacer acquisition where a single transcriptional regulator senses the presence...

  11. Electron injection mechanisms of green organic light-emitting devices fabricated utilizing a double electron injection layer consisting of cesium carbonate and fullerene

    International Nuclear Information System (INIS)

    Yang, J.S.; Choo, D.C.; Kim, T.W.; Jin, Y.Y.; Seo, J.H.; Kim, Y.K.

    2010-01-01

    Electron injection mechanisms of the luminance efficiency of green organic light-emitting devices (OLEDs) fabricated utilizing a cesium carbonate (Cs 2 CO 3 )/fullerene (C 60 ) heterostructure acting as an electron injection layer (EIL) were investigated. Current density-voltage and luminance-voltage measurements showed that the current densities and the luminances of the OLEDs with a Cs 2 CO 3 or Cs 2 CO 3 /C 60 EIL were higher than that of the OLEDs with a Liq EIL. The luminance efficiency of the OLEDs with a Cs 2 CO 3 EIL was almost three times higher than that of the OLEDs with a Liq EIL. Because the electron injection efficiency of the Cs 2 CO 3 layer in OLEDs was different from that of the C 60 layer, the luminance efficiency of the OLEDs with a double EIL consisting of a Cs 2 CO 3 layer and a C 60 layer was smaller than that of the OLEDs with a Cs 2 CO 3 EIL. The electron injection mechanisms of OLEDs with a Cs 2 CO 3 and C 60 double EIL are described on the basis of the experimental results.

  12. The utility of the Philips SRI-100 real time portal imaging device in a case of postoperative irradiation for prevention of heterotopic bone formation following total hip replacement

    International Nuclear Information System (INIS)

    Kiffer, J.D.; Quong, G.; Lawlor, M.; Schumer, W.; Aitken, L.; Wallace, A.

    1994-01-01

    The new Radiation Oncology Department at the Heidelberg Repatriation Hospital in Melbourne, Australia commenced operation in June 1992. As part of quality control the Philips SL-15 linear accelerator was fitted with the Philips SRI-100 Real Time Portal Imaging Device (RTPID), the first such apparatus in Australia. One of its major advantages over older systems is its ability to provide a permanent hard copy of the image of the field treated. The computer image can be immediately manipulated and enhanced on the screen (with respect to such qualities as brightness and contrast) prior to the printing of the hard copy. This is a significant improvement over the more cumbersome older port films that required developing time, without any pre-assessment of the image quality. The utility of the Philips SRI-100 RTPID is demonstrated in the case of a patient irradiated soon after total hip replacement, as prophylaxis against heterotopic bone formation (HBF). The rapidity and quality of image production is a major advantage in these patients where post operative pain may result in positional change between film exposure and image production. Extremely accurate shielding block position is essential to shield the prosthesis(and allow bone ingrowth for fixation) whilst avoiding inadvertent shielding of the areas at risk for HBF. A review of the literature on this topic is provided. 14 refs., 4 figs

  13. Influence of the spacer dielectric processes on PMOS junction properties

    International Nuclear Information System (INIS)

    Morin, Pierre; Wacquant, Francois; Juhel, Marc; Laviron, Cyrille; Lenoble, D.

    2005-01-01

    In this paper, the interaction observed in PMOS transistor between the boron lightly doped drain (LDD) extensions and the spacer oxide and nitride dielectrics have been studied, with a simple experimental methodology. Low thermal budget oxide obtained by sub-atmospheric chemical vapor deposition (SACVD) and nitride deposited by plasma process have been evaluated as spacer layers. The influence of the oxide liner hydrogen content is shown to be critical for the p type shallow junction. Indeed, during the activation anneal, hydrogen content increases the boron out diffusion from the extension into the oxide liner and yield to a significant dose loss in this area. Nitride porosity has also been studied. A lower boron dose loss is observed with a porous layer because hydrogen can degas out significantly from the oxide, during anneal, through the porous nitride film. These results confirm the model of boron out diffusion based on oxide hydrogen content proposed by Kohli. Finally, a boron diffusion mechanism driven by chemistry and enhanced by hydrogen defects is proposed

  14. Packaging design criteria modified fuel spacer burial box. Revision 1

    International Nuclear Information System (INIS)

    Stevens, P.F.

    1994-01-01

    Various Hanford facilities must transfer large radioactively contaminated items to burial/storage. Presently, there are eighteen Fuel Spacer Burial Boxes (FSBBs) available on the Hanford Site for transport of such items. Previously, the FSBBS were transported from a rail car to the burial trench via a drag-off operation. To allow for the lifting of the boxes into the burial trench, it will be necessary to improve the packagings lifting attachments and provide structural reinforcement. Additional safety improvements to the packaging system will be provided by the addition of a positive closure system and package ventilation. FSBBs that are modified in such a manner are referred to as Modified Fuel Spacer Burial Boxes (MFSBs). The criteria provided by this PDC will be used to demonstrate that the transfer of the MFSB will provide an equivalent degree of safety as would be provided by a package meeting offsite transportation requirements. This fulfills the onsite transportation safety requirements implemented in WHC-CM-2-14, Hazardous Material Packaging and Shipping. A Safety Analysis Report for Packaging (SARP) will be prepared to evaluate the safety of the transfer operation. Approval of the SARP is required to authorize transfer. Criteria are also established to ensure burial requirements are met

  15. A Study on Structural Strength of Irradiated Spacer Grid for PWR Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Baek, S. J.; Kim, D. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, J. I.; Kim, Y. H.; Lee, J. J. [KEPCO NF, Daejeon (Korea, Republic of)

    2014-10-15

    A fuel assembly consists of an array of fuel rods, spacer grids, guide thimbles, instrumentation tubes, and top and bottom nozzles. In PWR (Pressurized light Water Reactor) fuel assemblies, the spacer grids support the fuel rods by the friction forces between the fuel rods and springs/dimples. Under irradiation, the spacer grids supporting the fuel rods absorb vibration impacts due to the reactor coolant flow, and also bear static and dynamic loads during operation inside the nuclear reactor and transportation for spent fuel storage. Thus, it is important to understand the characteristics of deformation behavior and the change in structural strength of an irradiated spacer grid.. In the present study, the static compression test of a spacer grid was conducted to investigate the structural strength of the irradiated spacer grid in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. To evaluate the structural strength of an irradiated spacer grid, hot cell tests were carried out at IMEF of KAERI. The fuel assembly was dismantled and the irradiated spacer grid was obtained for the compression test. The apparatus for measuring the compression strength of the irradiated spacer grid was developed and installed successfully in the hot cell.

  16. Research report on development of spacer grid strap for AFA 3G fuel assembly

    International Nuclear Information System (INIS)

    Ye Yuandong

    2004-11-01

    The current development and tendency for fuel assemblies being of low leakage, high burn-up and long cycle fuel reload in the world are presented, and the necessity and feasibility to develop the spacer grid for high burn-up fuel assembly are elaborated. Considering all the activities in implementing of spacer grid and the technical difficulties in machining of tools, the major technological processes are introduced; the research program and the approaches to develop the spacer grid while research targets and overall schedule are defined and some key technical points and applicable practices are discussed. Finally the requirements and the conditions necessary for developing of spacer grid are proposed. (authors)

  17. Cervical interfacet spacers and maintenance of cervical lordosis.

    Science.gov (United States)

    Tan, Lee A; Straus, David C; Traynelis, Vincent C

    2015-05-01

    OBJECT The cervical interfacet spacer (CIS) is a relatively new technology that can increase foraminal height and area by facet distraction. These offer the potential to provide indirect neuroforaminal decompression while simultaneously enhancing fusion potential due to the relatively large osteoconductive surface area and compressive forces exerted on the grafts. These potential benefits, along with the relative ease of implantation during posterior cervical fusion procedures, make the CIS an attractive adjuvant in the management of cervical pathology. One concern with the use of interfacet spacers is the theoretical risk of inducing iatrogenic kyphosis. This work tests the hypothesis that interfacet spacers are associated with loss of cervical lordosis. METHODS Records from patients undergoing posterior cervical fusion at Rush University Medical Center between March 2011 and December 2012 were reviewed. The FacetLift CISs were used in all patients. Preoperative and postoperative radiographic data were reviewed and the Ishihara indices and cervical lordotic angles were measured and recorded. Statistical analyses were performed using STATA software. RESULTS A total of 64 patients were identified in whom 154 cervical levels were implanted with machined allograft interfacet spacers. Of these, 15 patients underwent anterior-posterior fusions, 4 underwent anterior-posterior-anterior fusions, and the remaining 45 patients underwent posterior-only fusions. In the 45 patients with posterior-only fusions, a total of 110 levels were treated with spacers. There were 14 patients (31%) with a single level treated, 16 patients (36%) with two levels treated, 5 patients (11%) with three levels treated, 5 patients (11%) with four levels treated, 1 patient (2%) with five levels treated, and 4 patients (9%) with six levels treated. Complete radiographic data were available in 38 of 45 patients (84%). On average, radiographic follow-up was obtained at 256.9 days (range 48-524 days

  18. Diffraction-based overlay for spacer patterning and double patterning technology

    Science.gov (United States)

    Lee, Byoung Hoon; Park, JeongSu; Lee, Jongsu; Park, Sarohan; Lim, ChangMoon; Yim, Dong-Gyu; Park, Sungki; Ryu, Chan-Ho; Morgan, Stephen; van de Schaar, Maurits; Fuchs, Andreas; Bhattacharyya, Kaustuve

    2011-03-01

    Overlay performance will be increasingly important for Spacer Patterning Technology (SPT) and Double Patterning Technology (DPT) as various Resolution Enhancement Techniques are employed to extend the resolution limits of lithography. Continuous shrinkage of devices makes overlay accuracy one of the most critical issues while overlay performance is completely dependent on exposure tool. Image Based Overlay (IBO) has been used as the mainstream metrology for overlay by the main memory IC companies, but IBO is not suitable for some critical layers due to the poor Tool Induced Shift (TIS) values. Hence new overlay metrology is required to improve the overlay measurement accuracy. Diffraction Based Overlay (DBO) is regarded to be an alternative metrology to IBO for more accurate measurements and reduction of reading errors. Good overlay performances of DBO have been reported in many articles. However applying DBO for SPT and DPT layers poses extra challenges for target design. New vernier designs are considered for different DPT and SPT schemes to meet overlay target in DBO system. In this paper, we optimize the design of the DBO target and the performance of DBO to meet the overlay specification of sub-3x nm devices which are using SPT and DPT processes. We show that the appropriate vernier design yields excellent overlay performance in residual and TIS. The paper also demonstrated the effects of vernier structure on overlay accuracy from SEM analysis.

  19. Measurement and CFD calculation of spacer loss coefficient for a tight-lattice fuel bundle

    International Nuclear Information System (INIS)

    In, Wang Kee; Shin, Chang Hwan; Kwack, Young Kyun; Lee, Chi Young

    2015-01-01

    Highlights: • Experiment and CFD analysis evaluated the pressure drop in a spacer grid. • The measurement and CFD errors for the spacer loss coefficient were estimated. • The spacer loss coefficient for the dual-cooled annular fuel bundle was determined. • The CFD prediction agrees with the measured spacer loss coefficient within 8%. - Abstract: An experiment and computational fluid dynamics (CFD) analysis were performed to evaluate the pressure drop in a spacer grid for a dual-cooled annular fuel (DCAF) bundle. The DCAF bundle for the Korean optimum power reactor (OPR1000) is a 12 × 12 tight-lattice rod array with a pitch-to-diameter ratio of 1.08 owing to a larger outer diameter of the annular fuel rod. An experiment was conducted to measure the pressure drop in spacer grid for the DCAF bundle. The test bundle is a full-size 12 × 12 rod bundle with 11 spacer grid. The test condition covers a Reynolds number range of 2 × 10 4 –2 × 10 5 by changing the temperature and flow rate of water. A CFD analysis was also performed to predict the pressure drop through a spacer grid using the full-size and partial bundle models. The pressure drop and loss coefficient of a spacer grid were predicted and compared with the experimental results. The CFD predictions of spacer pressure drop and loss coefficient agree with the measured values within 8%. The spacer loss coefficient for the DCAF bundle is estimated to be approximately 1.50 at a nominal operating condition of OPR1000, i.e., Re = 4 × 10 5

  20. Numerical investigation on practicability of reducing MCST by using grid spacer in a tight rod bundle

    International Nuclear Information System (INIS)

    Zhu, Xiaojing; Morooka, Shinichi; Oka, Yoshiaki

    2014-01-01

    Highlights: • Standard grid spacer design causes decreased heat transfer in a tight rod bundle. • Heat transfer is greatly enhanced by flow-enhancing features. • Swirling flow adversely affects the heat transfer downstream of grid spacer. • Enhanced heat transfer by existing grid spacer is limited in a short region. • Improved grid spacer can effectively reduce MCST. - Abstract: The numerical investigation was carried out to reveal the practicability of reducing the maximum cladding surface temperature (MCST) within the inner sub-channel of a tight, hexagon rod bundle using commercial CFD code STAR CCM+ 6.04. The special heat transfer and pressure drop characteristics caused by four existing grid spacer designs were discussed in detail by analyzing the effects of grid strap length, different flow enhancing features and different Reynolds numbers. It was found that the local heat transfer within the grid strap is greatly enhanced due to the raised flow velocity. Both the standard grid spacer and the grid spacer with split-vanes cause decreased heat transfer in the downstream region. The friction drag is very influential in the tight rod bundle and can eliminate the positive effect of flow blockage on the heat transfer performance. The grid spacer with flow blockage discs induces relatively good heat transfer performance and higher pressure drop within sub-channels, indicating a tradeoff between the heat transfer augmentation and the pressure drop. The combination of multiple existing grid spacers can reduce the MCST to a certain level, but the corresponding disadvantages cannot be ignored. The improved grid spacer design was proposed based on the overall considerations of heat transfer and pressure drop characteristics and has been proved more suitable to widely reduce MCST for SCWR than any other grid spacer designs involved in present study

  1. The influence of the preliminary garter spring spacer simulator clamping force in the pressure tube spacer -calandria tube hook-up simulator aging behaviour

    International Nuclear Information System (INIS)

    Gyongyosi, T.; Deloreanu, G.; Puiu, D.; Corbescu, B.; Anghel, N.; Dinu, E.

    2016-01-01

    The garter spring spacer is a specially constructed torsion spring used to fit-out the CANDU 6 fuel channel. The pressure tube ageing decreases the gap to the calandria tube. Continuous gap decrease directly affects the garter spring spacers behavior during fuel channel assembly operation. The preliminary clamping force value of the garter spring spacer assembly is important for its ageing behavior. This paper briefly describes the experimental technological facilities used for conducted the experiments and highlights some of the important moments during an experiment carried out in laboratory conditions, without using pressurized boiled water and irradiation working conditions. The results analysis and some conclusions are outlined at the end, pointing out that a garter spring spacer preliminary clamping force increase reduces the vibration response signal amplitude, and does not lead to its relaxation. The paper is dedicated to specialists working in research and technological engineering. (authors)

  2. Magnetic decoupling of ferromagnetic metals through a graphene spacer

    Energy Technology Data Exchange (ETDEWEB)

    Grimaldi, I.; Papagno, M. [Dipartimento di Fisica, Universitá della Calabria, Arcavacata di Rende (CS), 87036 (Italy); Ferrari, L. [Istituto dei Sistemi Complessi, Consiglio Nazionale delle Ricerche, Roma I-00133 (Italy); Istituto di Struttura della Materia, Consiglio Nazionale delle Ricerche, Trieste (Italy); Sheverdyaeva, P.M.; Mahatha, S.K. [Istituto di Struttura della Materia, Consiglio Nazionale delle Ricerche, Trieste (Italy); Pacilé, D., E-mail: daniela.pacile@fis.unical.it [Dipartimento di Fisica, Universitá della Calabria, Arcavacata di Rende (CS), 87036 (Italy); Istituto di Struttura della Materia, Consiglio Nazionale delle Ricerche, Trieste (Italy); Carbone, C. [Istituto di Struttura della Materia, Consiglio Nazionale delle Ricerche, Trieste (Italy)

    2017-03-15

    We study the magnetic coupling between different ferromagnetic metals (FMs) across a graphene (G) layer, and the role of graphene as a thin covalent spacer. Starting with G grown on a FM substrate (Ni or Co), we deposited on top at room temperature several FM metals (Fe, Ni, Co). By measuring the dichroic effect of 3p photoemission lines we detect the magnetization of the substrate and the sign of the exchange coupling in FM overlayer at room temperature. We show that the G layer magnetically decouples the FM metals. - Highlights: • The magnetic coupling between ferromagnets mediated by graphene is studied. • To this end, the linear dichroic effect in 3p photoemission lines is employed. • For selected junctions no magnetic coupling is attained through graphene. • Graphene inhibits the magnetic alignment that normally occurs between ferromagnets.

  3. Impact of underlap spacer region variation on electrostatic and analog performance of symmetrical high-k SOI FinFET at 20 nm channel length

    Science.gov (United States)

    Jain, Neeraj; Raj, Balwinder

    2017-12-01

    Continued scaling of CMOS technology to achieve high performance and low power consumption of semiconductor devices in the complex integrated circuits faces the degradation in terms of electrostatic integrity, short channel effects (SCEs), leakage currents, device variability and reliability etc. Nowadays, multigate structure has become the promising candidate to overcome these problems. SOI FinFET is one of the best multigate structures that has gained importance in all electronic design automation (EDA) industries due to its improved short channel effects (SCEs), because of its more effective gate-controlling capabilities. In this paper, our aim is to explore the sensitivity of underlap spacer region variation on the performance of SOI FinFET at 20 nm channel length. Electric field modulation is analyzed with spacer length variation and electrostatic performance is evaluated in terms of performance parameter like electron mobility, electric field, electric potential, sub-threshold slope (SS), ON current (I on), OFF current (I off) and I on/I off ratio. The potential benefits of SOI FinFET at drain-to-source voltage, V DS = 0.05 V and V DS = 0.7 V towards analog and RF design is also evaluated in terms of intrinsic gain (A V), output conductance (g d), trans-conductance (g m), gate capacitance (C gg), and cut-off frequency (f T = g m/2πC gg) with spacer region variations.

  4. Optimized spacer layer thickness for plasmonic-induced enhancement of photocurrent in a-Si:H

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, Z. M., E-mail: zaki.saleh@aauj.edu, E-mail: zakimsaleh@yahoo.com; Nasser, H.; Özkol, E.; Günöven, M.; Abak, K. [Middle East Technical University, Center for Solar Energy Research and Applications (GÜNAM) (Turkey); Canli, S. [Middle East Technical University, Central Laboratory (Turkey); Bek, A.; Turan, R. [Middle East Technical University, Center for Solar Energy Research and Applications (GÜNAM) (Turkey)

    2015-10-15

    Plasmonic interfaces consisting of silver nanoparticles of different sizes (50–100 nm) have been processed by the self-assembled dewetting technique and integrated to hydrogenated amorphous silicon (a-Si:H) using SiNx spacer layers to investigate the dependence of optical trapping enhancement on spacer layer thickness through the enhancements in photocurrent. Samples illuminated from the a-Si:H side exhibit a localized surface plasmon resonance (LSPR) that is red-shifted with the increasing particle size and broadened into the red with the increasing spacer layer thickness. The photocurrent measured in a-Si:H is not only consistent with the red-shift and broadening of the LSPR, but exhibits critical dependence on the spacer layer thickness also. The samples with plasmonic interfaces and a SiNx spacer layer exhibit appreciable enhancement of photocurrent compared with flat a-Si:H reference depending on the size of the Ag nanoparticle. Simulations conducted on one-dimensional square structures exhibit electric fields that are localized near the plasmonic structures but extend appreciably into the higher refractive index a-Si:H. These simulations produce a clear red-shift and broadening of extinction spectra for all spacer layer thicknesses and predict an enhancement in photocurrent in agreement with experimental results. The spectral dependence of photocurrent for six plasmonic interfaces with different Ag nanoparticle sizes and spacer layer thicknesses are correlated with the optical spectra and compared with the simulations to predict an optimal spacer layer thickness.

  5. Ertapenem Articulating Spacer for the Treatment of Polymicrobial Total Knee Arthroplasty Infection

    Directory of Open Access Journals (Sweden)

    Dragan Radoicic

    2016-01-01

    Full Text Available Introduction. Periprosthetic joint infections (PJIs are the primary cause of early failure of the total knee arthroplasty (TKA. Polymicrobial TKA infections are often associated with a higher risk of treatment failure. The aim of the study was to assess the efficacy of ertapenem loaded spacers in the treatment of polymicrobial PJI. Methods. There were 18 patients enrolled; nine patients with polymicrobial PJI treated with ertapenem loaded articulating spacers were compared to the group of 9 patients treated with vancomycin or ceftazidime loaded spacers. Results. Successful reimplantation with revision implants was possible in 66.67%. Ertapenem spacers were used in 6 cases in primary two-stage procedure and in 3 cases in secondary spacer exchange. Successful infection eradication was achieved in all cases; final reimplantation with revision knee arthroplasty implants was possible in 6 cases. Conclusion. Ertapenem can be successfully used as antimicrobial addition to the cement spacers in two-stage revision treatment of polymicrobial PJIs. However, this type of spacer may also be useful in the treatment of infections caused by monomicrobial extended spectrum beta-lactamases producing gram-negative bacilli. Further clinical studies are required to evaluate the efficacy and safety of ertapenem spacers in the treatment of polymicrobial and monomicrobial PJIs.

  6. Boiling transition phenomenon in BWR fuel assemblies effect of fuel spacer shape on critical power

    International Nuclear Information System (INIS)

    Yamamoto, Yasushi; Morooka, Shin-ichi; Mitsutake, Toru; Yokobori, Seiichi; Kimura, Jiro.

    1996-01-01

    A thorough understanding of the thermal-hydraulic phenomena near fuel spacer is necessary for the accurate prediction of the critical power of BWR fuel assemblies, and is thus essential for effective developments of a new BWR fuel assembly. The main purpose of this study is to develop an accurate method for predicting the effect of spacer shapes on critical power. Tests have been conducted under actual BWR operating conditions, using an annulus flow channel consisting of a heated rod and circular-tube channel, and BWR simulated 4x4 rod bundles with heater rods unheated just upsteam of spacer. The effect of spacer shapes on critical power was predicted analytically based on the droplet deposition rate estimation. The droplet deposition rate for different spacer shapes was calculated using a single-phase flow model. The prediction results were compared with the test results for the annulus flow channel using ring-type spacers. Analytical results of critical power agreed with measured critical power from point of the effects of changes in the rod-spacer clearance and the spacer thickness on critical power. (author)

  7. Modeling the effect of spacers and biofouling on forward osmosis performance

    KAUST Repository

    Mosqueira Santillá n, Marí a José

    2014-01-01

    and operational conditions. For this, a two dimensional numerical model for FO systems was developed using computational fluid dynamics (CFD). This model allowed the evaluation of the impact of (i) spacers and (ii) biofilm, and (iii) the combined impact of spacers

  8. Solution-processed organic tandem solar cells with embedded optical spacers

    NARCIS (Netherlands)

    Hadipour, Afshin; de Boer, Bert; Blom, Paul W. M.

    2007-01-01

    We demonstrate a solution-processed polymer tandem solar cell in which the two photoactive single cells are separated by an optical spacer. The use of an optical spacer allows for an independent optimization of both the electronic and optical properties of the tandem cell. The optical transmission

  9. Effect of plastic spacer handling on salbutamol lung deposition in asthmatic children

    DEFF Research Database (Denmark)

    Lipworth, Brian J; Lee, Daniel K C; Anhøj, Jacob

    2002-01-01

    AIMS: To study the effects of electrostatics in a plastic spacer on the lung deposition of salbutamol in asthmatic children. METHODS: Twenty-five children (5-12 years) with mild asthma were given salbutamol hydrofluoroalkane pressurized metered dose inhaler 400 micro g via a 750 ml plastic spacer...

  10. The CRISPR Spacer Space Is Dominated by Sequences from Species-Specific Mobilomes.

    Science.gov (United States)

    Shmakov, Sergey A; Sitnik, Vassilii; Makarova, Kira S; Wolf, Yuri I; Severinov, Konstantin V; Koonin, Eugene V

    2017-09-19

    Clustered regularly interspaced short palindromic repeats and CRISPR-associated protein (CRISPR-Cas) systems store the memory of past encounters with foreign DNA in unique spacers that are inserted between direct repeats in CRISPR arrays. For only a small fraction of the spacers, homologous sequences, called protospacers, are detectable in viral, plasmid, and microbial genomes. The rest of the spacers remain the CRISPR "dark matter." We performed a comprehensive analysis of the spacers from all CRISPR- cas loci identified in bacterial and archaeal genomes, and we found that, depending on the CRISPR-Cas subtype and the prokaryotic phylum, protospacers were detectable for 1% to about 19% of the spacers (~7% global average). Among the detected protospacers, the majority, typically 80 to 90%, originated from viral genomes, including proviruses, and among the rest, the most common source was genes that are integrated into microbial chromosomes but are involved in plasmid conjugation or replication. Thus, almost all spacers with identifiable protospacers target mobile genetic elements (MGE). The GC content, as well as dinucleotide and tetranucleotide compositions, of microbial genomes, their spacer complements, and the cognate viral genomes showed a nearly perfect correlation and were almost identical. Given the near absence of self-targeting spacers, these findings are most compatible with the possibility that the spacers, including the dark matter, are derived almost completely from the species-specific microbial mobilomes. IMPORTANCE The principal function of CRISPR-Cas systems is thought to be protection of bacteria and archaea against viruses and other parasitic genetic elements. The CRISPR defense function is mediated by sequences from parasitic elements, known as spacers, that are inserted into CRISPR arrays and then transcribed and employed as guides to identify and inactivate the cognate parasitic genomes. However, only a small fraction of the CRISPR spacers

  11. BWR fuel assembly with improved spacer and fuel bundle design for enhanced thermal-hydraulic performance

    International Nuclear Information System (INIS)

    Mildrum, C.M.; Taleyarkhan, R.P.

    1987-01-01

    In a fuel assembly having a bundle of elongated fuel rods disposed in side-by-side relationship so as to form an array of spaced fuel rods, an outer tubular flow channel surrounding the fuel rods so as to direct flow of coolant/moderator fluid along the fuel rods, a hollow water cross extending centrally through and interconnected with the outer flow channel so as to divide the channel into separate compartments and the bundle of fuelrods into a plurality of mini-bundles thereof being disposed in the compartments, and spacers axially displaced along the fuel rods in each of the mini-bundles thereof. Each spacer is composed of inner and outer means which together define spacer cells at corner, side and interior locations of the spacer and have respective protrusions formed thereon which extend into cells so as to maintain the fuel rods received through the spacer cells in laterally spaced relationships. The improvement is described which comprises: (a) a generally uniform poison coating within at least a majority of the fuel rods; (b) a predetermined pattern of fuel enrichment with respect to the fuel rods of each mini-bundle thereof which together with the uniform poison coating within the fuel rods ensures that the packing powers of the fuel rods in the corner and side cells of the spacers are less than the peaking power of a leading one of the fuel rods in the interior cells of the spacers; and (c) each of the fuel rods being received through the cells of each spacer having a diametric size smaller than that of each of the fuel rods received through the side and interior cells of each spacer, the diametric sizes of each of the fuel rods received through the side and interior cells of each spacer being generally equal

  12. Polyetheretherketone (PEEK) Spacers for Anterior Cervical Fusion: A Retrospective Comparative Effectiveness Clinical Trial.

    Science.gov (United States)

    Lemcke, Johannes; Al-Zain, Ferass; Meier, Ullrich; Suess, Olaf

    2011-01-01

    Anterior cervical decompression and fusion (ACDF) is the standard surgical treatment for radiculopathy and myelopathy. Polyetheretherketone (PEEK) has an elasticity similar to bone and thus appears well suited for use as the implant in ACDF procedures. The aim of this study is to examine the clinical and radiographic outcome of patients treated with standing alone PEEK spacers without bone morphogenic protein (BMP) or plating and to examine the influence of the different design of the two spacers on the rate of subsidence and dislocation. This retrospective comparative study reviewed 335 patients treated by ACDF in a specialized urban hospital for radiculopathy or myelopathy due to degenerative pathologies. The Intromed PEEK spacer was used in 181 patients from 3/2002 to 11/2004, and the AMT SHELL spacer was implanted in 154 patients from 4/2004 to 12/2007. The follow-up rate was 100% at three months post-op and 82.7% (277 patients) at one year. The patients were assessed with the Japanese Orthopedic Association (JOA) questionnaire and radiographically. At the one-year follow-up there were 118/277 patients with an excellent clinical outcome on the JOA, 112/277 with a good outcome, 20/277 with a fair outcome, and 27/277 with a poor outcome. Subsidence was observed in 13.3% of patients with the Intromed spacer vs 8.4% of the patients with the AMT SHELL. Dislocation of the spacer was observed in 10 of the 181 patients with Intromed spacers but in none of the 154 patients with Shell spacers. The study demonstrates that ACDF with standing alone PEEK cages leads to excellent and good clinical outcomes. The differences we observed in the subsidence rate between the two spacers were not significant and cannot be related to a single design feature of the spacers.

  13. SU-F-J-122: Rectal Sparing Reproducibility in Prostate Cancer Patients Treated with Hydrogel Spacer and Proton Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hedrick, S; Robison, B; Blakey, M; Artz, M; Renegar, J; Schreuder, A; Fagundes, M [Provision Center for Proton Therapy, Knoxville, TN (United States); Case, S [Vanderbilt University, Nashville, TN (United States)

    2016-06-15

    Purpose: Rectal hydrogel spacer has been shown to improve rectal sparing in prostate radiotherapy. The purpose of this study was to determine the reproducibility of rectal sparing throughout treatment in patients undergoing proton therapy. Methods: At our facility, prostate cancer patients are treated with pencil beam scanning proton therapy, utilizing an endorectal balloon (ERB) or rectal spacer hydrogel (Gel) “SpaceOAR” implant. All patients were treated with a full bladder and empty rectum (low residue diet and stool softeners). A quality assurance CT (QACT) was performed periodically throughout treatment to ensure rectal filling consistency and sparing in 41 patients treated with Gel. The treatment planning (TP) dose was calculated on each QACT and the rectum V90%, V75%, V65%, V50%, and V40% were recorded. QACT scans were acquired on day 0, week 1, week 3, and week 5. Results: 144 QACT scans were analyzed, each patient receiving 3–4 QACTs. Rectum V90% was within +/−1% of the TP dose in 70% of the QACTs and within +/−5% in 95% of scans. From previous data analyses, our ERB rectum V90% average is 6%. This value was used as an upper threshold for the Gel QACT analysis. 5 of the 41 patients (12%), corresponding to 7 QACTs, had a rectum V90% that exceeded 6% on one or more QACTs. However, the average rectal V90% measured over multiple QACTs never exceeded 6%. 55% of the QACTs had a rectum volume within 5cc of the TPCT volume, 68% were within 10cc. Conclusion: In this study, we have shown that a majority of our prostate patients can maintain consistent rectal sparing when treated with a hydrogel spacer. QACT rectal V90% exceeding our threshold was most often related to increased rectal filling and gas, which was addressed with improved dietary compliance and the intensification of stool softeners or laxatives.

  14. SU-F-J-122: Rectal Sparing Reproducibility in Prostate Cancer Patients Treated with Hydrogel Spacer and Proton Therapy

    International Nuclear Information System (INIS)

    Hedrick, S; Robison, B; Blakey, M; Artz, M; Renegar, J; Schreuder, A; Fagundes, M; Case, S

    2016-01-01

    Purpose: Rectal hydrogel spacer has been shown to improve rectal sparing in prostate radiotherapy. The purpose of this study was to determine the reproducibility of rectal sparing throughout treatment in patients undergoing proton therapy. Methods: At our facility, prostate cancer patients are treated with pencil beam scanning proton therapy, utilizing an endorectal balloon (ERB) or rectal spacer hydrogel (Gel) “SpaceOAR” implant. All patients were treated with a full bladder and empty rectum (low residue diet and stool softeners). A quality assurance CT (QACT) was performed periodically throughout treatment to ensure rectal filling consistency and sparing in 41 patients treated with Gel. The treatment planning (TP) dose was calculated on each QACT and the rectum V90%, V75%, V65%, V50%, and V40% were recorded. QACT scans were acquired on day 0, week 1, week 3, and week 5. Results: 144 QACT scans were analyzed, each patient receiving 3–4 QACTs. Rectum V90% was within +/−1% of the TP dose in 70% of the QACTs and within +/−5% in 95% of scans. From previous data analyses, our ERB rectum V90% average is 6%. This value was used as an upper threshold for the Gel QACT analysis. 5 of the 41 patients (12%), corresponding to 7 QACTs, had a rectum V90% that exceeded 6% on one or more QACTs. However, the average rectal V90% measured over multiple QACTs never exceeded 6%. 55% of the QACTs had a rectum volume within 5cc of the TPCT volume, 68% were within 10cc. Conclusion: In this study, we have shown that a majority of our prostate patients can maintain consistent rectal sparing when treated with a hydrogel spacer. QACT rectal V90% exceeding our threshold was most often related to increased rectal filling and gas, which was addressed with improved dietary compliance and the intensification of stool softeners or laxatives.

  15. Predicting the impact of feed spacer modification on biofouling by hydraulic characterization and biofouling studies in membrane fouling simulators

    KAUST Repository

    Siddiqui, Amber; Lehmann, S.; Bucs, Szilard; Fresquet, M.; Fel, L.; Prest, E.I.E.C.; Ogier, J.; Schellenberg, C.; van Loosdrecht, M.C.M.; Kruithof, J.C.; Vrouwenvelder, Johannes S.

    2016-01-01

    Feed spacers are an essential part of spiral-wound reverse osmosis (RO) and nanofiltration (NF) membrane modules. Geometric modification of feed spacers is a potential option to reduce the impact of biofouling on the performance of membrane systems

  16. Ultrafast electron transfer in all-carbon-based SWCNT-C60 donor-acceptor nanoensembles connected by poly(phenylene-ethynylene) spacers

    Science.gov (United States)

    Barrejón, Myriam; Gobeze, Habtom B.; Gómez-Escalonilla, María J.; Fierro, José Luis G.; Zhang, Minfang; Yudasaka, Masako; Iijima, Sumio; D'Souza, Francis; Langa, Fernando

    2016-08-01

    Building all-carbon based functional materials for light energy harvesting applications could be a solution to tackle and reduce environmental carbon output. However, development of such all-carbon based donor-acceptor hybrids and demonstration of photoinduced charge separation in such nanohybrids is a challenge since in these hybrids part of the carbon material should act as an electron donating or accepting photosensitizer while the second part should fulfil the role of an electron acceptor or donor. In the present work, we have successfully addressed this issue by synthesizing covalently linked all-carbon-based donor-acceptor nanoensembles using single-walled carbon nanotubes (SWCNTs) as the donor and C60 as the acceptor. The donor-acceptor entities in the nanoensembles were connected by phenylene-ethynylene spacer units to achieve better electronic communication and to vary the distance between the components. These novel SWCNT-C60 nanoensembles have been characterized by a number of techniques, including TGA, FT-IR, Raman, AFM, absorbance and electrochemical methods. The moderate number of fullerene addends present on the side-walls of the nanotubes largely preserved the electronic structure of the nanotubes. The thermodynamic feasibility of charge separation in these nanoensembles was established using spectral and electrochemical data. Finally, occurrence of ultrafast electron transfer from the excited nanotubes in these donor-acceptor nanohybrids has been established by femtosecond transient absorption studies, signifying their utility in building light energy harvesting devices.Building all-carbon based functional materials for light energy harvesting applications could be a solution to tackle and reduce environmental carbon output. However, development of such all-carbon based donor-acceptor hybrids and demonstration of photoinduced charge separation in such nanohybrids is a challenge since in these hybrids part of the carbon material should act as an

  17. In vitro performance of three combinations of spacers and pressurized metered dose inhalers for treatment in children

    DEFF Research Database (Denmark)

    Berg, E; Madsen, J; Bisgaard, H

    1998-01-01

    The performance of pressurized metered dose inhalers (pMDIs) and spacers in correct dose recommendations is important, but limited information on dose delivery and fine-particle dose from different combinations of spacers and pMDIs is available. In this study, three combinations of spacers and p...... and spacers, with the NebuChamber giving the highest dose, both as delivered dose and in droplets account for these differences....

  18. Effects of spacer layer on growth, stress and magnetic properties of sputtered permalloy film

    International Nuclear Information System (INIS)

    Cheng, S.F.; Lubitz, P.; Zheng, Y.; Edelstein, A.S.

    2004-01-01

    A microelectromechanical (MEMS) flux concentrator (J. Appl. phys. 91 (2002) 7795), is a device that will minimize 1/f noise in magnetic sensors by modulating the magnetic field at the position of the sensor. This requires high permeability and low stress permalloy (Py) films to be deposited on the MEMS flaps (J. Appl. phys. 91 (2002) 7795). Py (Ni 80 Fe 20 ) films from 100 to 560 nm thick were deposited on Si substrates using DC magnetron sputtering. The effects of deposition conditions on the grain morphology, texture, stress and magnetic properties were studied. Lower sputtering pressure changes film stress from tension to compression and increases the out of film plane texture, while higher power increases tension and texture. Neutral film stress was obtained with 100 W of sputtering power and 1.25 mTorr of Ar gas pressure. With increasing thickness, the Py film was found to develop a stripe-like domain configuration at low fields because of strong out-of-plane magnetic anisotropy. The critical thickness is around 180 nm.This may be explained by a competition between planar demagnetization fields and columnar magnetic anisotropy. Adding 5 nm of Ta or Cr layer as spacer successfully broke up the continuity of the magnetic structure and allowed us to produce high-permeability films by fabricating (Ta/Py) or (Cr/Py) multilayer films with each Py layer thinner than the critical thickness

  19. System for measuring spacer pin pitch in a nuclear fuel assembly

    International Nuclear Information System (INIS)

    Isono, Kenji; Tateishi, Yoshinori; Mano, Tadashi.

    1975-01-01

    Object: To reduce the period for discriminating whether or not spacer pin pitch is satisfactory by simultaneously inserting a number of reference rods into a nuclear fuel assembly spacer ring element of a reactor and arranging them such that they can be simultaneously withdrawn to simplify the withdrawing operation. Structure: A spacer provided with a ring element which clamps a nuclear fuel element is supported on a spacer support with a rod secured to the support as a guide and is secured to the support by securing means. A vertically movable structure with a reference rod provided upright and thru-holes formed in two support plates provided in the same row as the spacer ring element is operated by a fluid pressure mechanism to simultaneously insert the reference rod into the spacer ring element. The reference rod is mounted in support plates via ball bearings such that it is slightly movable in the horizontal direction, and it is aligned with respect to the core of the ring element. The intercore distance of the reference rod is measured with the reference rod inserted in the ring element, thereby measuring the space pin pitch. From the results of measurement, discrimination as to whether the spacer is satisfactory or not is made. (Kamimura, M.)

  20. A Study on Cell Size of Irradiated Spacer Grid for PWR Fuel

    International Nuclear Information System (INIS)

    Jin, Y. G.; Kim, G. S.; Ryu, W. S. and others

    2014-01-01

    The spacer grids supporting the fuel rods absorb vibration impacts due to the reactor coolant flow, and grid spring force decreases under irradiation. This reduction of contact force might cause grid-to-rod fretting wear. The fretting failure of the fuel rod is one of the recent significant issues in the nuclear industry from an economical as well as a safety concern. Thus, it is important to understand the characteristics of cell spring behavior and the change in size of grid cells for an irradiated spacer grid. In the present study, the dimensional measurement of a spacer grid was conducted to investigate the cell size of an irradiated spacer grid in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. To evaluate the fretting wear performance of an irradiated spacer grid, hot cell tests were carried out at IMEF of KAERI. Hot cell examinations include dimensional measurements for the irradiated spacer grid. The change of cell sizes was dependent on the direction of the spacer grids, leading to significant gap variations. It was found that the change in size of the cell springs due to irradiation-induced stress relaxation and creep during the fuel residency in the reactor core affect the contact behavior between the fuel rod and the cell spring

  1. Antibiotic-impregnated articulating cement spacer for infected total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Parag Garg

    2011-01-01

    Full Text Available Background : Standard treatment of chronic infected total knee arthroplasty (TKA is a two-stage revision, the first step being placement of an antibiotic-impregnated cement spacer. Here we describe the results of a new technique (modification of the Goldstien′s technique for intraoperative manufacture of a customized articulating spacer at minimal cost and with relatively good conformity and longevity. Materials and Methods : Thirty-six infected knees underwent this procedure from June 2002 to May 2007. The technique consists of using the freshened femur and tibia interface as molds wrapped in a tin foil for manufacturing the two components of the spacer with antibiotic-impregnated methyl methycrylate cement. We used the spacer and the femoral component of the trial set of a TKA system to mold them to perfect articulation. We also reinforced the spacer with a K-wire scaffold to prevent fracture of the cement mantle in the last 21 cases. Results : All 36 knees showed excellent results in terms of infection control, mobility, and stability. There was significant improvement in the WOMAC and Knee Society Scores (20 and 39 points respectively. There were two fractures of the spacers in the initial 15 cases that did not have K-wire scaffolding but none in the last 21 that had reinforcement. Conclusion : This technique provides a more conforming spacer, with good range of motion and stability. The reinforcement helps in preventing the fracture of the cement mantle and is cost effective.

  2. Experimental investigation of turbulent flow through spacer grids in fuel rod bundles

    International Nuclear Information System (INIS)

    Caraghiaur, Diana; Anglart, Henryk; Frid, Wiktor

    2009-01-01

    This paper contains experimental data of pressure, velocity and turbulence intensity in a 24-rod fuel bundle with spacer grids. Detailed pressure measurements inside the spacer grid have been obtained by use of a sliding pressure-sensing rod. Laser Doppler Velocimetry technique was used to measure the local axial velocity and its fluctuating component upstream and downstream of the spacer grid in sub-channels with different blockage ratios. The measurements show a changing pattern in function of radial position in the cross-section of the fuel bundle. For sub-channels close to the box wall, the turbulence intensity suddenly increases just downstream of the spacer and then gradually decays. In inner sub-channels, however, the turbulence intensity downstream of the spacer decreases below its upstream value and then gradually increases until it reaches the maximum value at approximately two spacer heights. The present study reveals that spacer effects, such as local pressure distribution and turbulence intensity enhancement, not only depend exclusively on the local geometry details, but also on the location in the cross-section of the rod bundle.

  3. Experimental investigation of turbulent flow through spacer grids in fuel rod bundles

    Energy Technology Data Exchange (ETDEWEB)

    Caraghiaur, Diana [Royal Institute of Technology, Division of Nuclear Reactor Technology, Department of Physics, School of Engineering Sciences, AlbaNova University Center, SE-106 91 Stockholm (Sweden)], E-mail: dianac@kth.se; Anglart, Henryk [Royal Institute of Technology, Division of Nuclear Reactor Technology, Department of Physics, School of Engineering Sciences, AlbaNova University Center, SE-106 91 Stockholm (Sweden); Frid, Wiktor [Swedish Radiation Safety Authority, Reactor Technology and Structural Integrity, SE-171 16 Stockholm (Sweden)

    2009-10-15

    This paper contains experimental data of pressure, velocity and turbulence intensity in a 24-rod fuel bundle with spacer grids. Detailed pressure measurements inside the spacer grid have been obtained by use of a sliding pressure-sensing rod. Laser Doppler Velocimetry technique was used to measure the local axial velocity and its fluctuating component upstream and downstream of the spacer grid in sub-channels with different blockage ratios. The measurements show a changing pattern in function of radial position in the cross-section of the fuel bundle. For sub-channels close to the box wall, the turbulence intensity suddenly increases just downstream of the spacer and then gradually decays. In inner sub-channels, however, the turbulence intensity downstream of the spacer decreases below its upstream value and then gradually increases until it reaches the maximum value at approximately two spacer heights. The present study reveals that spacer effects, such as local pressure distribution and turbulence intensity enhancement, not only depend exclusively on the local geometry details, but also on the location in the cross-section of the rod bundle.

  4. Success of Two-Stage Reimplantation in Patients Requiring an Interim Spacer Exchange.

    Science.gov (United States)

    George, Jaiben; Miller, Evan M; Curtis, Gannon L; Klika, Alison K; Barsoum, Wael K; Mont, Michael A; Higuera, Carlos A

    2018-03-23

    Some patients undergoing a 2-stage revision for a periprosthetic joint infection require a repeat spacer in the interim (removal of existing spacer with insertion of a new spacer or spacer exchange) due to persistent infection. The objectives of this study are to (1) determine the factors associated with patients who receive a repeat spacer and (2) compare the infection-free survival (overall and stratified by joint type) of reimplantation in patients who did or did not receive a repeat spacer. From 2001 to 2014, 347 hip or knee 2-stage revisions that finally underwent reimplantation and had a minimum 2-year follow-up were identified. An interim spacer exchange was performed in 59 (17%) patients (exchange cohort). Patient-related and organism-related factors were compared between the exchange and non-exchange cohorts. Kaplan-Meier survival curves were performed to assess the success (absence of signs of infection, reoperation for infection, periprosthetic joint infection-related mortality) of both cohorts. Patients in the exchange group had higher comorbidity score (P = .020), prolonged time to reimplantation (P exchange cohort, and 78% (knee 77%, hip 78%) in the non-exchange cohort (P = .020). Patients requiring an interim spacer exchange were found to have more comorbidities, prolonged treatment period, and were more likely to be infected with a resistant organism. About one-third of such patients became reinfected within 5 years compared to only one-fifth of the patients without an interim spacer exchange. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Characterization of feed channel spacer performance using geometries obtained by X-ray computed tomography

    KAUST Repository

    Haaksman, Viktor A.

    2016-09-09

    Spiral-wound membrane modules used in water treatment for water reuse and desalination make use of spacer meshes for keeping the membrane leaves apart and for enhancing the mass transfer. Computational fluid dynamics (CFD) has gained importance in the design of new spacers with optimized hydrodynamic characteristics, but this requires a precise description of the spacer geometry. This study developed a method to obtain accurate three-dimensional (3-D) geometry representations for any given spacer design from X-ray computed tomography (CT) scans. The method revealed that the filaments of industrial spacers have a highly variable cross-section size and shape, which impact the flow characteristics in the feed channel. The pressure drop and friction factors were calculated from numerical simulations on five commercially available feed spacers used in practice. Model solutions compared well to experimental data measured using a flow cell for average velocities up to 0.2 m/s, as used in industrial reverse osmosis and nanofiltration membrane operations. A newly-proposed spacer geometry with alternating strand thickness was tested, which was found to yield a lower pressure drop while being highly efficient in converting the pumping power into membrane shear. Numerical model solutions using CFD with geometries from CT scans were closer to measurements than those obtained using the traditional circular cross-section strand simplification, indicating that CT scans are very well suitable to approximate real feed spacer geometries. By providing detailed insight on the spacer filament shape, CT scans allow better quantification of local distribution of velocity and shear, possibly leading to more accurate estimations of fouling and concentration polarization. © 2016 Elsevier B.V.

  6. APPLICATIONS OF SPACERS MADE WITH DOUBLE BAR RASCHEL MACHINE

    Directory of Open Access Journals (Sweden)

    DÍAZ-GARCÍA Pablo

    2016-05-01

    Full Text Available Nowadays, textile technologies develop to adapt their different techniques for creating new products for the different sectors of application every day. Particularly, warp knitted fabrics and warp-knitting technology have applications in all different groups of technical textiles. It could be the most applied technique, the most versatile technology to develop new textile products for the new textile market. Warp knitted fabrics play the most important role among the technical textile fabrics. This technology is used in different product groups such as mobile textiles (car seat covers, dashboard cover, industrial textiles (composites, medical textiles (anti-decubitus blankets, sports textiles and foundation garments (bra cups, pads for swimwear. This study presents some examples of the application of this technology in some markets Within the market of technical textile, medical textile has an increasing relevance and knitted fabrics and knitting technology, at the same time, play a very important role in the fields of technical and medical textiles. Studies have demonstrated that knitted structures possess excellent mechanical properties and can promote more effective regenerative medicine, tissue repair, ligament, tendon cartilage, reconstruction, etc. The aim of this paper is to present different possibilities of textiles developed with this kind of structures, to present different alternatives, different examples of products obtained with this kind of textile structure combined with the correct kind of textile fiber. In this kind of technology, double-bar Raschel machines used for producing three-dimensional textiles, spacers, play an important role.

  7. Efficient self-assembly of DNA-functionalized fluorophores and gold nanoparticles with DNA functionalized silicon surfaces: the effect of oligomer spacers

    Science.gov (United States)

    Milton, James A.; Patole, Samson; Yin, Huabing; Xiao, Qiang; Brown, Tom; Melvin, Tracy

    2013-01-01

    Although strategies for the immobilization of DNA oligonucleotides onto surfaces for bioanalytical and top-down bio-inspired nanobiofabrication approaches are well developed, the effect of introducing spacer molecules between the surface and the DNA oligonucleotide for the hybridization of nanoparticle–DNA conjugates has not been previously assessed in a quantitative manner. The hybridization efficiency of DNA oligonucleotides end-labelled with gold nanoparticles (1.4 or 10 nm diameter) with DNA sequences conjugated to silicon surfaces via hexaethylene glycol phosphate diester oligomer spacers (0, 1, 2, 6 oligomers) was found to be independent of spacer length. To quantify both the density of DNA strands attached to the surfaces and hybridization with the surface-attached DNA, new methodologies have been developed. Firstly, a simple approach based on fluorescence has been developed for determination of the immobilization density of DNA oligonucleotides. Secondly, an approach using mass spectrometry has been created to establish (i) the mean number of DNA oligonucleotides attached to the gold nanoparticles and (ii) the hybridization density of nanoparticle–oligonucleotide conjugates with the silicon surface–attached complementary sequence. These methods and results will be useful for application with nanosensors, the self-assembly of nanoelectronic devices and the attachment of nanoparticles to biomolecules for single-molecule biophysical studies. PMID:23361467

  8. Mapping bound plasmon propagation on a nanoscale stripe waveguide using quantum dots: influence of spacer layer thickness

    Directory of Open Access Journals (Sweden)

    Chamanei S. Perera

    2015-10-01

    Full Text Available In this paper we image the highly confined long range plasmons of a nanoscale metal stripe waveguide using quantum emitters. Plasmons were excited using a highly focused 633 nm laser beam and a specially designed grating structure to provide stronger incoupling to the desired mode. A homogeneous thin layer of quantum dots was used to image the near field intensity of the propagating plasmons on the waveguide. We observed that the photoluminescence is quenched when the QD to metal surface distance is less than 10 nm. The optimised spacer layer thickness for the stripe waveguides was found to be around 20 nm. Authors believe that the findings of this paper prove beneficial for the development of plasmonic devices utilising stripe waveguides.

  9. Experimental and numerical investigation of water flow through spacer grids of nuclear fuel elements using the Open FOAM code

    International Nuclear Information System (INIS)

    Vidal, Guilherme A.M.; Vieira, Tiago A.S.; Castro, Higor F.P.

    2017-01-01

    With the advancement and development of computational tools, the studies of thermofluidodynamic behavior in nuclear fuel elements have been developed in recent years. Of the devices present in these elements, the spacing grids received more attention. They have kept the fuel rods equally spaced and have fins that aim to improve the heat transfer process between the water and the fuel element. Therefore, the grids present an important structural and thermal function. This work was carried out with the purpose of verifying and validating simulations of spacer grids using OpenFOAM (2017) software of Computational Fluid Dynamics (CFD). The simulations were validated using results obtained through the commercial CFD program, Ansys CFX, and experiments available in the literature and obtained in test sections assembled on the Water-Air Circuit (CCA) of the CDTN thermo-hydraulic laboratory

  10. Investigation of a 10 kWh sorption heat storage device for effective utilization of low-grade thermal energy

    International Nuclear Information System (INIS)

    Zhao, Y.J.; Wang, R.Z.; Li, T.X.; Nomura, Y.

    2016-01-01

    Heating and domestic hot water for family houses represents a notable share of energy consumption. However, sufficient space for the installation of thermal energy storage (TES) components may not be available in family houses or urban areas, where space may be restricted and expensive. Sorption TES devices seem to be a promising means of replacing conventional TES devices and reducing the occupied space for its high energy density. In this paper, a 10 kWh short-term sorption TES device was developed and investigated. The employed composite sorbent was formed from lithium chloride (LiCl) with the addition of expanded graphite (EG). The principle of sorption TES for the LiCl/water working pair is first illustrated. This prototype was tested under conditions representative of transition or winter seasons. Under the conditions used (charging temperature T_c_h_a at 85 °C, discharging temperature T_d_i_s at 40 °C, condensing temperature T_c at 18 °C, and evaporating temperature T_e at 30 °C), the heat storage capacity can reach 10.25 kWh, of which sorption heat accounts for approximately 60%. The heat storage density obtained was 873 Wh per kg of composite sorbent or 65.29 kWh/m"3, while the heat storage density of hot water tank was about 33.02 kWh/m"3. - Highlights: • A 10 kWh short-term sorption thermal energy device was developed. • The device was tested under conditions of transition and winter seasons. • The performance of the device was improved by recovering waste heat. • The sorption thermal energy device was compared with a 300-L hot water tank.

  11. Relationship Between the Elevated Muscle FDG Uptake in the Distal Upper Extremities on PET/CT Scan and Prescan Utilization of Mobile Devices in Young Patients.

    Science.gov (United States)

    Bai, Xia; Wang, Xuemei; Zhuang, Hongming

    2018-03-01

    It is common to notice increased FDG activity in the muscles of the forearms or hands on PET/CT images. The purpose of this study was to determine relationship between the prevalence of increased FDG activity in the forearms or hands and using mobile devices prior to the FDG PET/CT study. A total of 443 young patients with ages between 5 and 19 years who underwent FDG PET/CT scan were included in this retrospective analysis. All patients had FDG PET/CT with their arms within the field of views. The images were reviewed for elevated activity in the muscles of the distal upper extremities (DUEs), which include forearms and hands. The preimaging questionnaire/interview records regarding using mobile devices prior to FDG PET/CT were also reviewed and compared with the imaging findings. Most patients (72.0% [319/443]) used mobile devices more than 60 minutes in the period of 24 hours prior to the FDG PET/CT study. Elevated uptake in the muscles in the DUEs was observed in 38.6% (123/319) of these patients. In contrast, among 124 patients who did not use the mobile devices or used the mobile device minimally prior to the study, only 6.5% (8/124) of them had elevated FDG activity in the DUEs. The difference persisted following stratification analysis for sex, age, and serum glucose level in our patient population. Increased FDG uptake in the muscles of the DUEs in young patients is commonly seen in those who used mobile devices prior to PET/CT study. Recommendation should be considered to reduce using mobile devices prior to FDG PET/CT study in young patient population.

  12. Articulating spacers used in two-stage revision of infected hip and knee prostheses abrade with time.

    Science.gov (United States)

    Fink, Bernd; Rechtenbach, Annett; Büchner, Hubert; Vogt, Sebastian; Hahn, Michael

    2011-04-01

    Articulating spacers used in two-stage revision surgery of infected prostheses have the potential to abrade and subsequently induce third-body wear of the new prosthesis. We asked whether particulate material abraded from spacers could be detected in the synovial membrane 6 weeks after implantation when the spacers were removed for the second stage of the revision. Sixteen hip spacers (cemented prosthesis stem articulating with a cement cup) and four knee spacers (customized mobile cement spacers) were explanted 6 weeks after implantation and the synovial membranes were removed at the same time. The membranes were examined by xray fluorescence spectroscopy, xray diffraction for the presence of abraded particles originating from the spacer material, and analyzed in a semiquantitative manner by inductively coupled plasma mass spectrometry. Histologic analyses also were performed. We found zirconium dioxide in substantial amounts in all samples, and in the specimens of the hip synovial lining, we detected particles that originated from the metal heads of the spacers. Histologically, zirconium oxide particles were seen in the synovial membrane of every spacer and bone cement particles in one knee and two hip spacers. The observations suggest cement spacers do abrade within 6 weeks. Given the presence of abrasion debris, we recommend total synovectomy and extensive lavage during the second-stage reimplantation surgery to minimize the number of abraded particles and any retained bacteria.

  13. Effects of grid spacer with mixing vane on entrainments and depositions in two-phase annular flows

    Directory of Open Access Journals (Sweden)

    Akimaro Kawahara

    2015-06-01

    Full Text Available The effects of mixing vanes (MVs attached to a grid spacer on the characteristics of air–water annular flows were experimentally investigated. To know the effects, a grid spacer with or without MV was inserted in a vertical circular pipe of 16-mm internal diameter. For three cases (i.e., no spacer, spacer without MV, and spacer with MV, the liquid film thickness, liquid entrainment fraction, and deposition rate were measured by the constant current method, single liquid film extraction method, and double liquid film extraction method, respectively. The MVs significantly promote the re-deposition of liquid droplets in the gas core flow into the liquid film on the channel walls. The deposition mass transfer coefficient is three times higher for the spacer with MV than for the spacer without MV, even for cases 0.3-m downstream from the spacer. The liquid film thickness becomes thicker upstream and downstream for the spacer with MV, compared with the thickness for the spacer without MV and for the case with no spacer.

  14. Controlling the exciton emission of gold coated GaAs-AlGaAs core-shell nanowires with an organic spacer layer

    Science.gov (United States)

    Kaveh, M.; Gao, Q.; Jagadish, C.; Ge, J.; Duscher, G.; Wagner, H. P.

    2016-12-01

    Excitons are the most prominent optical excitations and controlling their emission is an important step towards new optical devices. We have investigated the exciton emission from uncoated and gold/aluminum quinoline (Alq3) coated GaAs-AlGaAs-GaAs core-shell nanowires (NWs) using temperature-, intensity- and polarization dependent photoluminescence (PL). Plasmonic GaAs-AlGaAs-GaAs NWs with a ˜10 nm thick Au coating but without an Alq3 spacer layer reveal a significant reduction of the PL intensity of the exciton emission compared with the uncoated NW sample. Plasmonic NW samples with the same nominal Au coverage and an additional Alq3 interlayer of 3 or 6 nm thickness show a clearly stronger PL intensity which increases with rising Alq3 spacer thickness. Time-resolved (TR) PL measurements reveal an increase of the exciton decay rate by a factor of up to two with decreasing Alq3 spacer thickness suggesting the presence of Förster energy transfer from NW excitons to plasmon oscillations in the gold film. The weak change of the decay time, however, indicates that Förster energy-transfer is only partially responsible for the PL quenching in the gold coated NWs. The main reason for the reduction of the PL emission is attributed to a gold induced band-bending in the GaAs NW core which causes exciton dissociation. With increasing Alq3 spacer thickness the band-bending decreases leading to a reduction of the exciton dissociation and PL quenching. Our interpretation is supported by electron energy loss spectroscopy measurements which show a signal reduction and blue shift of defect (possibly EL2) transitions when gold particles are deposited on NWs compared with bare or Alq3 coated NWs.

  15. The independent loss model with ordered insertions for the evolution of CRISPR spacers.

    Science.gov (United States)

    Baumdicker, F; Huebner, A M I; Pfaffelhuber, P

    2018-02-01

    Today, the CRISPR (clustered regularly interspaced short palindromic repeats) region within bacterial and archaeal genomes is known to encode an adaptive immune system. We rely on previous results on the evolution of the CRISPR arrays, which led to the ordered independent loss model, introduced by Kupczok and Bollback (2013). When focusing on the spacers (between the repeats), new elements enter a CRISPR array at rate θ at the leader end of the array, while all spacers present are lost at rate ρ along the phylogeny relating the sample. Within this model, we compute the distribution of distances of spacers which are present in all arrays in a sample of size n. We use these results to estimate the loss rate ρ from spacer array data for n=2 and n=3. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. The effect of endoskeleton on antibiotic impregnated cement spacer for treating deep hip infection

    Directory of Open Access Journals (Sweden)

    Hsu Wei-Hsiu

    2011-01-01

    Full Text Available Abstract Backgrounds A two-stage revision arthroplasty was suggested optimal treatment for deep infections in hip joint. The effect of endoskeleton of cement spacers on the interim function and infection control remains unclear. Methods From Jan. 2004 to Dec. 2007, we collected a prospective cohort of consecutive 34 patients who treated with two-stage revision total hip arthroplasty for deep infection of hip joint. In group 1, fifteen patients were treated by a novel design augmented with hip compression screw while nineteen patients were treated by traditional design in group 2. Results No fracture of cement spacer occurred in group 1 while 6 cases developed spacer failure in group 2. (p Conclusions Patients being treated for deep infection of hip joint using cement spacer augmented with stronger endoskeleton have lower pain levels and better joint function between stages.

  17. Biofouling patterns in spacer filled channels: High resolution imaging for characterization of heterogeneous biofilms

    KAUST Repository

    Staal, Marc; Siddiqui, Amber; van Loosdrecht, Mark; Vrouwenvelder, Johannes S.

    2017-01-01

    reverse osmosis (RO) and nanofiltration (NF) membrane filtration systems used for desalination and wastewater reuse to produce high quality (drinking) water. These spiral wound membrane modules contain mesh-like spacer structures used to create

  18. A Facile Technique to Make Articulating Spacers for Infected Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Yu-Ping Su

    2009-03-01

    Conclusion: Treating infected total knee arthroplasty with these self-made articulating spacers eradicates infection effectively, improves the life quality before reimplantation and provides good final results without significant complications.

  19. Reentrainment of droplet from grid spacer in mist flow portion of LOCA reflood of PWR

    International Nuclear Information System (INIS)

    Lee, S.L.; Cho, S.K.; Sheen, H.J.

    1983-01-01

    An investigation is made on the influence of a quenched grid spacer on the greatly enhanced heat transfer from heated fuel rods during the mist flow phase of emergency reflood of loss of coolant accident (LOCA) of a pressurized water reactor (PWR). The situation for the case of a dry grid spacer before its quenching has not been covered in this study. The experimental technique used is a relatively simple optical scheme which combines the reference-mode laser-Doppler anemometry making use of the scattering of a light beam from a droplet. The results reveal that the large droplets in the mist flow, which are intercepted by the grid spacer, are responsible for the creation of a large number of smaller droplets. These small droplets, due to their large surface area to mass ratios, can serve as superb evaporative cooling agents to heat transfer downstream of the grid spacer

  20. Non linear fe analysis on the static buckling behavior of the spacer grid structures

    International Nuclear Information System (INIS)

    Song, K.N.; Yoon, K.H.

    2001-01-01

    In this study considered is the static buckling behavior of spacer grids in the fuel assembly, which are required to have a sufficient strength against an accident like earthquake. Special attention is given to the finite element modeling of the spot-welding and the constraints between the spacer strips assembled together: it is found that a proper treatment of the constraints is critical for accurate assessment of the buckling behavior including strain localization at the point of spot welding. The buckling strength of the 17 x 17 spacer grid, which is difficult to analyze due to a large number of degrees of freedom, is estimated from analysis for the smaller models 3 x 3, 5 x 5, 7 x 7, and 9 x 9 spacer grids. (authors)

  1. Spacer geometry and particle deposition in spiral wound membrane feed channels

    KAUST Repository

    Radu, A.I.

    2014-11-01

    Deposition of microspheres mimicking bacterial cells was studied experimentally and with a numerical model in feed spacer membrane channels, as used in spiral wound nanofiltration (NF) and reverse osmosis (RO) membrane systems. In-situ microscopic observations in membrane fouling simulators revealed formation of specific particle deposition patterns for different diamond and ladder feed spacer orientations. A three-dimensional numerical model combining fluid flow with a Lagrangian approach for particle trajectory calculations could describe very well the in-situ observations on particle deposition in flow cells. Feed spacer geometry, positioning and cross-flow velocity sensitively influenced the particle transport and deposition patterns. The deposition patterns were not influenced by permeate production. This combined experimental-modeling approach could be used for feed spacer geometry optimization studies for reduced (bio)fouling. © 2014 Elsevier Ltd.

  2. Computer-Aided Design Method of Warp-Knitted Jacquard Spacer Fabrics

    Directory of Open Access Journals (Sweden)

    Li Xinxin

    2016-06-01

    Full Text Available Based on a further study on knitting and jacquard principles, this paper presents a mathematical design model to make computer-aided design of warp-knitted jacquard spacer fabrics more efficient. The mathematical model with matrix method employs three essential elements of chain notation, threading and Jacquard designing. With this model, the processing to design warp-knitted jacquard spacer fabrics with CAD software is also introduced. In this study, the sports shoes which have separated functional areas according to the feet structure and characteristics of movement are analysed. The results show the different patterns on Jacquard spacer fabrics that are seamlessly stitched with jacquard technics. The computer-aided design method of warp-knitted jacquard spacer fabrics is efficient and simple.

  3. Spacer geometry and particle deposition in spiral wound membrane feed channels

    KAUST Repository

    Radu, A.I.; van Steen, M.S.H.; Vrouwenvelder, Johannes S.; van Loosdrecht, Mark C.M.; Picioreanu, C.

    2014-01-01

    Deposition of microspheres mimicking bacterial cells was studied experimentally and with a numerical model in feed spacer membrane channels, as used in spiral wound nanofiltration (NF) and reverse osmosis (RO) membrane systems. In-situ microscopic

  4. CRISPR Spacer Arrays for Detection of Viral Signatures from Acidic Hot Springs

    Science.gov (United States)

    Snyder, J. C.; Bateson, M. M.; Suciu, D.; Young, M. J.

    2010-04-01

    Viruses are the most abundant life-like entities on the planet Earth. Using CRISPR spacer sequences, we have developed a microarray-based approach to detecting viral signatures in the acidic hot springs of Yellowstone.

  5. Suppression of subthreshold characteristics variation for junctionless multigate transistors using high-k spacers

    International Nuclear Information System (INIS)

    Lou, Haijun; Zhang, Baili; Li, Dan; Lin, Xinnan; He, Jin; Chan, Mansun

    2015-01-01

    In this work, the high-k spacer is proposed to suppress the subthreshold characteristics variation of junctionless multigate transistor (JMT) with non-ideal sidewall angle for the first time. It is demonstrated that the variation of subthreshold characteristics induced by the changing sidewall angle is efficiently suppressed by high-k spacers due to the enhanced corner effect through the fringe capacitance, and the electrostatic integrity of JMTs is also improved at sub-22 nm gate length. Two key parameters of high-k spacer, the thickness and length, have been optimized in terms of the suppression of subthreshold characteristics variation. Then their optimal values are proposed. The benefit of high-k spacer makes JMTs more scalable. (paper)

  6. Effect of plastic spacer handling on salbutamol lung deposition in asthmatic children

    DEFF Research Database (Denmark)

    Lipworth, Brian J; Lee, Daniel K C; Anhøj, Jacob

    2002-01-01

    AIMS: To study the effects of electrostatics in a plastic spacer on the lung deposition of salbutamol in asthmatic children. METHODS: Twenty-five children (5-12 years) with mild asthma were given salbutamol hydrofluoroalkane pressurized metered dose inhaler 400 micro g via a 750 ml plastic spacer...... on separate days. Blood samples were taken for plasma salbutamol at 5, 10, 15 and 20 min after inhalation to measure lung bioavailability as a surrogate for relative lung dose. With immediate inhalation following actuation, a new rinsed spacer (NewRinsed ) was compared with a used spacer after repeated daily...... log transformed and expressed as geometric mean fold difference for the average plasma salbutamol concentration (Cav) over 20 min. RESULTS: There were significant differences (P NewRinsed 1.92 fold (95% CI 1.15, 3...

  7. Impact of a Protective Vest and Spacer Garment on Exercise-Heat Strain

    National Research Council Canada - National Science Library

    Cheuvront, Samuel N; Goodman, Daniel A; Kenefick, Robert W; Montain, Scott J; Sawka, Michael N

    2008-01-01

    ...). Volunteers wore the US Army battle dress uniform (trial B), B + protective vest (trial P), and B + P + spacer garment (trial S). Biophysical clothing properties were determined and found similar to many law enforcement, industry, and sports ensembles...

  8. A study on the characteristics of the spacer spring by finite element method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Keun; Kim, Hyung Kyu; Kim, Kyu Tae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-06-01

    The mechanical integrity of spacer springs in KOFA was certified through the mechanical tests by KWU. In this report, the spacer spring characteristics were obtained by using a commercial FEM code ANSYS, and the calculated results were compared with the mechanical test results. It has been found that the analytical results from ANSYS were in good agreement with the test results in the actual working range of the spacer springs even though some errors occurred in the range of initial spring deflection. The errors were thought to occur due to the simplified boundary conditions and the nominal dimensions which are used in calculations rather than the as-fabricated dimensions. Though the results from ANSYS are not fully satisfied, the analytical method in this report has been verified to be used as a method for investigating the characteristic of spacer springs roughly before conducting mechanical tests. 8 tabs., 25 figs (Author) .new.

  9. Biofouling patterns in spacer filled channels: High resolution imaging for characterization of heterogeneous biofilms

    KAUST Repository

    Staal, Marc

    2017-08-15

    Biofilms develop in heterogeneous patterns at a µm scale up to a cm scale, and patterns become more pronounced when biofilms develop under complex hydrodynamic flow regimes. Spatially heterogeneous biofilms are especially known in spiral wound reverse osmosis (RO) and nanofiltration (NF) membrane filtration systems used for desalination and wastewater reuse to produce high quality (drinking) water. These spiral wound membrane modules contain mesh-like spacer structures used to create an intermembrane space and improve water mixing. Spacers create inhomogeneous water flow patterns resulting in zones favouring biofilm growth, possibly leading to biofouling thus hampering water production. Oxygen sensing planar optodes were used to visualize variations in oxygen decrease rates (ODR). ODR is an indication of biofilm activity. In this study, ODR images of multiple repetitive spacer areas in a membrane fouling simulator were averaged to produce high resolution, low noise ODR images. Averaging 40 individual spacer areas improved the ODR distribution image significantly and allowed comparison of biofilm patterning over a spacer structure at different positions in an RO filter. This method clearly showed that most active biofilm accumulated on and in direct vicinity of the spacer. The averaging method was also used to calculate the deviation of ODR patterning from individual spacer areas to the average ODR pattern, proposing a new approach to determine biofilm spatial heterogeneity. This study showed that the averaging method can be applied and that the improved, averaged ODR images can be used as an analytical, in-situ, non-destructive method to assess and quantify the effect of membrane installation operational parameters or different spacer geometries on biofilm development in spiral wound membrane systems characterized by complex hydrodynamic conditions.

  10. Technology of electron beam welding for Zr-4 alloy spacer grid

    International Nuclear Information System (INIS)

    Pei Qiusheng; Wu Xueyi; Yang Qishun

    1989-10-01

    The welding technology for Zr-4 alloy spacer grid by using vacuum electron beam was studied. Through a series of welding technological experiments, metallographic examinations of seam structure and detecting tests for welding defect by X-ray defectoscopy, a good welding technology was selected to meet the requirements. The experimental results indicated that the Zr-4 alloy spacer grid welded by vacuum electron beam welding is feasible

  11. Characterizing the Utility and Limitations of Repurposing an Open-Field Optical Imaging Device for Fluorescence-Guided Surgery in Head and Neck Cancer Patients.

    Science.gov (United States)

    Moore, Lindsay S; Rosenthal, Eben L; Chung, Thomas K; de Boer, Esther; Patel, Neel; Prince, Andrew C; Korb, Melissa L; Walsh, Erika M; Young, E Scott; Stevens, Todd M; Withrow, Kirk P; Morlandt, Anthony B; Richman, Joshua S; Carroll, William R; Zinn, Kurt R; Warram, Jason M

    2017-02-01

    The purpose of this study was to assess the potential of U.S. Food and Drug Administration-cleared devices designed for indocyanine green-based perfusion imaging to identify cancer-specific bioconjugates with overlapping excitation and emission wavelengths. Recent clinical trials have demonstrated potential for fluorescence-guided surgery, but the time and cost of the approval process may impede clinical translation. To expedite this translation, we explored the feasibility of repurposing existing optical imaging devices for fluorescence-guided surgery. Consenting patients (n = 15) scheduled for curative resection were enrolled in a clinical trial evaluating the safety and specificity of cetuximab-IRDye800 (NCT01987375). Open-field fluorescence imaging was performed preoperatively and during the surgical resection. Fluorescence intensity was quantified using integrated instrument software, and the tumor-to-background ratio characterized fluorescence contrast. In the preoperative clinic, the open-field device demonstrated potential to guide preoperative mapping of tumor borders, optimize the day of surgery, and identify occult lesions. Intraoperatively, the device demonstrated robust potential to guide surgical resections, as all peak tumor-to-background ratios were greater than 2 (range, 2.2-14.1). Postresection wound bed fluorescence was significantly less than preresection tumor fluorescence (P open-field imaging device was successfully repurposed to distinguish cancer from normal tissue in the preoperative clinic and throughout surgical resection. This study illuminated the potential for existing open-field optical imaging devices with overlapping excitation and emission spectra to be used for fluorescence-guided surgery. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  12. Hydrogen pellet injection device

    International Nuclear Information System (INIS)

    Kanno, Masahiro.

    1992-01-01

    In a hydrogen pellet injection device, a nozzle block having a hydrogen gas supply channel is disposed at the inner side of a main cryogenic housing, and an electric resistor is attached to the block. Further, a nozzle block and a hydrogen gas introduction pipe are attached by way of a thermal insulating spacer. Electric current is supplied to the resistor to positively heat the nozzle block and melt remaining solid hydrogen in the hydrogen gas supply channel. Further, the effect of temperature elevation due to the resistor is prevented from reaching the side of the hydrogen gas introduction pipe by the thermal insulation spacer. That is, the temperature of the nozzle block is directly and positively elevated, to melt the solid hydrogen rapidly. Preparation operation from the injection of the hydrogen pellet to the next injection can be completed in a shorter period of time compared with a conventional case thereby enabling to make the test more efficient. Further, only the temperature of the nozzle block is elevated with no effect of temperature elevation due to the resistor to other components by the thermal insulation flange. (N.H.)

  13. 5 X 5 rod bundle flow field measurements downstream a PWR spacer grid

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Higor F.P.; Silva, Vitor V A.; Santos, André A.C.; Veloso, Maria A.F., E-mail: higorfabiano@gmail.com, E-mail: mdora@nuclear.ufmg.br, E-mail: vitors@cdtn.br, E-mail: aacs@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    The spacer grids are structures present in nuclear fuel assembly of Pressurized Water Reactors (PWR). They play an important structural role and also assist in heat removal through the assembly by promoting increased turbulence of the flow. Understanding the flow dynamics downstream the spacer grid is paramount for fuel element design and analysis. This paper presents water flow velocity profiles measurements downstream a spacer grid in a 5 x 5 rod bundle test rig with the objective of highlighting important fluid dynamic behavior near the grid and supplying data for CFD simulation validation. These velocity profiles were obtained at two different heights downstream the spacer grid using a LDV (Laser Doppler Velocimetry) through the top of test rig. The turbulence intensities and patterns of the swirl and cross flow were evaluated. The tests were conducted for Reynolds numbers ranging from 1.8 x 10{sup 4} to 5.4 x 10{sup 4}. This experimental research was carried out in thermo-hydraulics laboratory of Nuclear Technology Development Center – CDTN. Results show great repeatability and low uncertainties (< 1.24 %). Details of the flow field show how the mixture and turbulence induced by the spacer grid quickly decays downstream the spacer grid. It is shown that the developed methodology can supply high resolution low uncertainty results that can be used for validation of CFD simulations. (author)

  14. 5 X 5 rod bundle flow field measurements downstream a PWR spacer grid

    International Nuclear Information System (INIS)

    Castro, Higor F.P.; Silva, Vitor V A.; Santos, André A.C.; Veloso, Maria A.F.

    2017-01-01

    The spacer grids are structures present in nuclear fuel assembly of Pressurized Water Reactors (PWR). They play an important structural role and also assist in heat removal through the assembly by promoting increased turbulence of the flow. Understanding the flow dynamics downstream the spacer grid is paramount for fuel element design and analysis. This paper presents water flow velocity profiles measurements downstream a spacer grid in a 5 x 5 rod bundle test rig with the objective of highlighting important fluid dynamic behavior near the grid and supplying data for CFD simulation validation. These velocity profiles were obtained at two different heights downstream the spacer grid using a LDV (Laser Doppler Velocimetry) through the top of test rig. The turbulence intensities and patterns of the swirl and cross flow were evaluated. The tests were conducted for Reynolds numbers ranging from 1.8 x 10"4 to 5.4 x 10"4. This experimental research was carried out in thermo-hydraulics laboratory of Nuclear Technology Development Center – CDTN. Results show great repeatability and low uncertainties (< 1.24 %). Details of the flow field show how the mixture and turbulence induced by the spacer grid quickly decays downstream the spacer grid. It is shown that the developed methodology can supply high resolution low uncertainty results that can be used for validation of CFD simulations. (author)

  15. A study on improvement of analytical prediction model for spacer grid pressure loss coefficients

    International Nuclear Information System (INIS)

    Lim, Jonh Seon

    2002-02-01

    Nuclear fuel assemblies used in the nuclear power plants consist of the nuclear fuel rods, the control rod guide tubes, an instrument guide tube, spacer grids,a bottom nozzle, a top nozzle. The spacer grid is the most important component of the fuel assembly components for thermal hydraulic and mechanical design and analyses. The spacer grids fixed with the guide tubes support the fuel rods and have the very important role to activate thermal energy transfer by the coolant mixing caused to the turbulent flow and crossflow in the subchannels. In this paper, the analytical spacer grid pressure loss prediction model has been studied and improved by considering the test section wall to spacer grid gap pressure loss independently and applying the appropriate friction drag coefficient to predict pressure loss more accurately at the low Reynolds number region. The improved analytical model has been verified based on the hydraulic pressure drop test results for the spacer grids of three types with 5x5, 16x16, 17x17 arrays, respectively. The pressure loss coefficients predicted by the improved analytical model are coincident with those test results within ±12%. This result shows that the improved analytical model can be used for research and design change of the nuclear fuel assembly

  16. Numerical simulation of bubble motion about a grid spacer in a rod bundle

    International Nuclear Information System (INIS)

    Zhang, Zheng; Hosokawa, Shigeo; Hayashi, Kosuke; Tomiyama, Akio

    2009-01-01

    Numerical simulations based on a three-dimensional two-way bubble tracking method are carried out to predict bubble motions in a square duct with an obstacle and in a two-by-three rod bundle with a grid spacer. Comparisons between measured and predicted bubble motions demonstrate that the two-way bubble tracking method gives good predictions for trajectories of small bubbles in the upstream side of the grid spacer in the rod bundle geometry. The predicted bubble trajectories clearly show that bubbles are apt to migrate toward the rod surface in the vicinity of the bottom of the grid spacer. Analysis of forces acting on the bubbles confirms that pressure gradient force induced by the presence of the spacer is the main cause of the bubble lateral migration toward the rod surface. Motions of steam bubbles at a nominal operating condition of a pressurized water reactor (PWR) are also predicted by using the bubble tracking method, which indicates that steam bubbles also migrate toward the rod surface at the upstream side of the spacer due to the spacer-induced pressure gradient force. (author)

  17. BWR fuel assembly having fuel rod spacers axially positioned by exterior springs

    International Nuclear Information System (INIS)

    Taleyarkhan, R.P.

    1988-01-01

    In a fuel assembly having spaced fuel rods, an outer hollow tubular flow channel surrounding the fuel rods so as to direct flow of coolant/moderator fluid there-along, and at least one spacer being disposed along the channel and about the fuel rods so as to maintain them in side-by-side spaced relationship, an arrangement for disposing the spacer in a desired axial position along the fuel rods is described comprising: yieldably resilient springs disposed between an interior side of the outer channel and an exterior side of the spacer. The springs have an inherent spring bias directed away from the exterior sides of the spacers and toward the interior side of the channel such that by contact with the channel and spacer the springs assume states in which they are deflected away from the channel interior side so as to exert sufficient compressive contacting force thereon to maintain the spacer substantially stationary in the desired axial position along the fuel rods

  18. Time spans and spacers : Molecular phylogenetic explorations in the Cladophora complex (Chlorophyta) from the perspective of rDNA gene and spacer sequences

    NARCIS (Netherlands)

    Bakker, Frederik Theodoor

    1995-01-01

    In this study, phylogenetic relationships among genera, species and biogeographic representatives of single Cladophora species within the Cladophorales were analyzed using rDNA gene and spacer sequences. Based on phylogenetic analysis of 18S rRNA gene sequences, the Cladophora complex is shown to be

  19. Predicting the impact of feed spacer modification on biofouling by hydraulic characterization and biofouling studies in membrane fouling simulators

    KAUST Repository

    Siddiqui, Amber

    2016-12-22

    Feed spacers are an essential part of spiral-wound reverse osmosis (RO) and nanofiltration (NF) membrane modules. Geometric modification of feed spacers is a potential option to reduce the impact of biofouling on the performance of membrane systems. The objective of this study was to evaluate the biofouling potential of two commercially available reference feed spacers and four modified feed spacers. The spacers were compared on hydraulic characterization and in biofouling studies with membrane fouling simulators (MFSs). The virgin feed spacer was characterized hydraulically by their resistance, measured in terms of feed channel pressure drop, performed by operating MFSs at varying feed water flow rates. Short-term (9 days) biofouling studies were carried out with nutrient dosage to the MFS feed water to accelerate the biofouling rate. Long-term (96 days) biofouling studies were done without nutrient dosage to the MFS feed water. Feed channel pressure drop was monitored and accumulation of active biomass was quantified by adenosine tri phosphate (ATP) determination. The six feed spacers were ranked on pressure drop (hydraulic characterization) and on biofouling impact (biofouling studies). Significantly different trends in hydraulic resistance and biofouling impact for the six feed spacers were observed. The same ranking for biofouling impact on the feed spacers was found for the (i) short-term biofouling study with nutrient dosage and the (ii) long-term biofouling study without nutrient dosage. The ranking for hydraulic resistance for six virgin feed spacers differed significantly from the ranking of the biofouling impact, indicating that hydraulic resistance of clean feed spacers does not predict the hydraulic resistance of biofouled feed spacers. Better geometric design of feed spacers can be a suitable approach to minimize impact of biofouling in spiral wound membrane systems.

  20. Reducing post-surgical adhesions utilizing a drug-enhanced device: sodium carboxymethylcellulose aqueous gel/poly(p-dioxanone) and Tranilast

    International Nuclear Information System (INIS)

    Cui, Helen; Gensini, Michel; Kataria, Ram; Twaddle, Tricia; Zhang, John; Wadsworth, Scott; Cooper, Kevin; Petrilli, Janel; Rodgers, Kathleen; DiZerega, Gere

    2009-01-01

    Post-surgical adhesion formation has numerous deleterious side effects in a wide variety of surgical settings. Physical barriers used together with laparoscopy were developed to reduce tissue trauma seen with open procedures. However, despite surgeons' meticulous techniques and the use of such barriers, adhesion formation remains a serious clinical problem, creating complications that cost the health care system over $1 billion annually. Our laboratories have combined a previously marketed drug, Tranilast, with a sodium carboxymethylcellulose (NaCMC) gel in a sustained release formulation using poly(p-dioxanone) (PDO) to provide a locally delivered medicated device that significantly reduces adhesions. This paper describes the preparation of the gel and the sustained release formulation, its key physical properties, and its sustained release kinetics. Pre-clinical data on inhibition of adhesion formation by the sustained release poly(p-dioxanone)/sodium carboxymethylcellulose/Tranilast drug enhanced device are also presented.

  1. Metal insulator semiconductor solar cell devices based on a Cu2O substrate utilizing h-BN as an insulating and passivating layer

    International Nuclear Information System (INIS)

    Ergen, Onur; Gibb, Ashley; Vazquez-Mena, Oscar; Zettl, Alex; Regan, William Raymond

    2015-01-01

    We demonstrate cuprous oxide (Cu 2 O) based metal insulator semiconductor Schottky (MIS-Schottky) solar cells with efficiency exceeding 3%. A unique direct growth technique is employed in the fabrication, and hexagonal boron nitride (h-BN) serves simultaneously as a passivation and insulation layer on the active Cu 2 O layer. The devices are the most efficient of any Cu 2 O based MIS-Schottky solar cells reported to date

  2. Metal insulator semiconductor solar cell devices based on a Cu{sub 2}O substrate utilizing h-BN as an insulating and passivating layer

    Energy Technology Data Exchange (ETDEWEB)

    Ergen, Onur; Gibb, Ashley; Vazquez-Mena, Oscar; Zettl, Alex, E-mail: azettl@berkeley.edu [Department of Physics, University of California at Berkeley, Berkeley, California 94720 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Kavli Energy Nanosciences Institute at the University of California, Berkeley, and the Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Regan, William Raymond [Department of Physics, University of California at Berkeley, Berkeley, California 94720 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    2015-03-09

    We demonstrate cuprous oxide (Cu{sub 2}O) based metal insulator semiconductor Schottky (MIS-Schottky) solar cells with efficiency exceeding 3%. A unique direct growth technique is employed in the fabrication, and hexagonal boron nitride (h-BN) serves simultaneously as a passivation and insulation layer on the active Cu{sub 2}O layer. The devices are the most efficient of any Cu{sub 2}O based MIS-Schottky solar cells reported to date.

  3. Device for rearranging control rods of experimental reactors

    International Nuclear Information System (INIS)

    Louda, J.

    1975-01-01

    The invention claims a means for the adjustment of control rods in experimental reactors with a continuously variable pitch of the fuel element spacer. The proposed device permits obtaining maximum variability in the physical modelling of nuclear power reactor cores in experimental reactors. (F.M.)

  4. Experimental investigations of turbulent flows in rod bundles with and without spacer grids

    International Nuclear Information System (INIS)

    Trippe, G.

    1979-07-01

    In the thermofluiddynamic design of liquid metal cooled reactor fuel elements the lack of experimentally confirmed knowledge of the three-dimensional flow events in rod bundles provided with spacer grids has appeared as a significant problem. To close this gap of knowledge, detailed measurements of the local velocities were made on a 19-rod bundle model. The Pitot method of differential pressure measurements was used as the measuring system. In the first part of the work the fully developed flow regime not influenced by spacers was investigated. A simple relation was derived for distributing the mass flow among the subchannels of a rod bundle; it is but slightly dependent on the Reynolds number. This relation allows a quick, coarse calculation of the distribution of the undisturbed, fully developed mass flow in bundles with similar geometries. By evaluation of further experiments known from the literature, empirical relationships were found for the local velocity distribution within the subchannels of such bundles. In the second part the effect of grid shaped spacers was investigated. The three-dimensional flow events caused by the spacers were completely recorded and interpreted physically. The deeper understanding of these flow processes can now serve to improve the model concept used in the present design computer programs. Single results of the investigations which take primary importance are the quantitative relations existing between the changes of mass flow in the bundle boundary zone, caused by a spacer, and the geometry of this spacer. The transferability to other bundle geometries was discussed and delimited. Moreover, it was shown that the mass flow in the bundle boundary zone can be successively reduced by spacers placed one behind the other in the bundle. A noticeable dependence of flow events on the Reynolds number was not found for the range relevant in practical application (30.000 [de

  5. A functional analysis of the spacer of V(DJ recombination signal sequences.

    Directory of Open Access Journals (Sweden)

    Alfred Ian Lee

    2003-10-01

    Full Text Available During lymphocyte development, V(DJ recombination assembles antigen receptor genes from component V, D, and J gene segments. These gene segments are flanked by a recombination signal sequence (RSS, which serves as the binding site for the recombination machinery. The murine Jbeta2.6 gene segment is a recombinationally inactive pseudogene, but examination of its RSS reveals no obvious reason for its failure to recombine. Mutagenesis of the Jbeta2.6 RSS demonstrates that the sequences of the heptamer, nonamer, and spacer are all important. Strikingly, changes solely in the spacer sequence can result in dramatic differences in the level of recombination. The subsequent analysis of a library of more than 4,000 spacer variants revealed that spacer residues of particular functional importance are correlated with their degree of conservation. Biochemical assays indicate distinct cooperation between the spacer and heptamer/nonamer along each step of the reaction pathway. The results suggest that the spacer serves not only to ensure the appropriate distance between the heptamer and nonamer but also regulates RSS activity by providing additional RAG:RSS interaction surfaces. We conclude that while RSSs are defined by a "digital" requirement for absolutely conserved nucleotides, the quality of RSS function is determined in an "analog" manner by numerous complex interactions between the RAG proteins and the less-well conserved nucleotides in the heptamer, the nonamer, and, importantly, the spacer. Those modulatory effects are accurately predicted by a new computational algorithm for "RSS information content." The interplay between such binary and multiplicative modes of interactions provides a general model for analyzing protein-DNA interactions in various biological systems.

  6. A functional analysis of the spacer of V(D)J recombination signal sequences.

    Science.gov (United States)

    Lee, Alfred Ian; Fugmann, Sebastian D; Cowell, Lindsay G; Ptaszek, Leon M; Kelsoe, Garnett; Schatz, David G

    2003-10-01

    During lymphocyte development, V(D)J recombination assembles antigen receptor genes from component V, D, and J gene segments. These gene segments are flanked by a recombination signal sequence (RSS), which serves as the binding site for the recombination machinery. The murine Jbeta2.6 gene segment is a recombinationally inactive pseudogene, but examination of its RSS reveals no obvious reason for its failure to recombine. Mutagenesis of the Jbeta2.6 RSS demonstrates that the sequences of the heptamer, nonamer, and spacer are all important. Strikingly, changes solely in the spacer sequence can result in dramatic differences in the level of recombination. The subsequent analysis of a library of more than 4,000 spacer variants revealed that spacer residues of particular functional importance are correlated with their degree of conservation. Biochemical assays indicate distinct cooperation between the spacer and heptamer/nonamer along each step of the reaction pathway. The results suggest that the spacer serves not only to ensure the appropriate distance between the heptamer and nonamer but also regulates RSS activity by providing additional RAG:RSS interaction surfaces. We conclude that while RSSs are defined by a "digital" requirement for absolutely conserved nucleotides, the quality of RSS function is determined in an "analog" manner by numerous complex interactions between the RAG proteins and the less-well conserved nucleotides in the heptamer, the nonamer, and, importantly, the spacer. Those modulatory effects are accurately predicted by a new computational algorithm for "RSS information content." The interplay between such binary and multiplicative modes of interactions provides a general model for analyzing protein-DNA interactions in various biological systems.

  7. Expected utility without utility

    OpenAIRE

    Castagnoli, E.; Licalzi, M.

    1996-01-01

    This paper advances an interpretation of Von Neumann–Morgenstern’s expected utility model for preferences over lotteries which does not require the notion of a cardinal utility over prizes and can be phrased entirely in the language of probability. According to it, the expected utility of a lottery can be read as the probability that this lottery outperforms another given independent lottery. The implications of this interpretation for some topics and models in decision theory are considered....

  8. Knitting Technologies And Tensile Properties Of A Novel Curved Flat-Knitted Three-Dimensional Spacer Fabrics

    Directory of Open Access Journals (Sweden)

    Li Xiaoying

    2015-09-01

    Full Text Available This paper introduces a knitting technique for making innovative curved three-dimensional (3D spacer fabrics by the computer flat-knitting machine. During manufacturing, a number of reinforcement yarns made of aramid fibres are inserted into 3D spacer fabrics along the weft direction to enhance the fabric tensile properties. Curved, flat-knitted 3D spacer fabrics with different angles (in the warp direction were also developed. Tensile tests were carried out in the weft and warp directions for the two spacer fabrics (with and without reinforcement yarns, and their stress–strain curves were compared. The results showed that the reinforcement yarns can reduce the fabric deformation and improve tensile stress and dimensional stability of 3D spacer fabrics. This research can help the further study of 3D spacer fabric when applied to composites.

  9. Utility of Mobile Communication Devices as a Tool to Improve Adherence to Antiretroviral Treatment in HIV-infected Children and Young Adults in Argentina.

    Science.gov (United States)

    Stankievich, Erica; Malanca, Adriana; Foradori, Irene; Ivalo, Silvina; Losso, Marcelo

    2018-04-01

    Optimal adherence is critical to achieve the benefits of antiretroviral treatment (ART). The aim of the study is to evaluate the use of mobile devices as a strategy to improve adherence to ART, measured by viral load (VL) in HIV+ patients less than 25 years of age. A prospective study was conducted in a cohort of HIV+ patients less than 25 years of age. HIV+ patients, on ART, VL >1000 copies/mL, using mobile devices and suboptimal adherence were included. The intervention was based on a mobile generic contact twice a month using text message and Facebook during 32 weeks. Extended communications were generated by the patient. VL was performed before and after the intervention. Twenty-five patients were included. Three were excluded and 22 patients were enrolled. Mean age was 17.2 ± 6.1 years (range: 6-25); 15 (68%) were female; mean baseline VL was 25,100 copies/mL (range: 1020-500,000 copies/mL), mean log was 4.3 (range: 3-5.7 log). Each participant received a total of 16 contacts; 84% (296) were answered by the patient and 54% (189) of the contacts generated extended communications. After the strategy implementation, 20/22 VL results were available: 13/20 (65%) were undetectable, 14/20 (70%) had VL mobile devices and social networks is a valid tool to improve ART adherence in HIV+ pediatric and young adults, evaluated through VL. The strategy is feasible. The reminder messages trigger additional communications between patients and health provider and better engagement with HIV care. Longer follow-up time is needed.

  10. Ion therapy of prostate cancer: daily rectal dose reduction by application of spacer gel

    International Nuclear Information System (INIS)

    Rucinski, Antoni; Brons, Stephan; Richter, Daniel; Habl, Gregor; Debus, Jürgen; Bert, Christoph; Haberer, Thomas; Jäkel, Oliver

    2015-01-01

    Ion beam therapy represents a promising approach to treat prostate cancer, mainly due to its high conformity and radiobiological effectiveness. However, the presence of prostate motion, patient positioning and range uncertainties may deteriorate target dose and increase exposure of organs at risk. Spacer gel injected between prostate and rectum may increase the safety of prostate cancer (PC) radiation therapy by separating the rectum from the target dose field. The dosimetric impact of the application of spacer gel for scanned carbon ion therapy of PC has been analyzed at Heidelberg Ion-Beam Therapy Center (HIT). The robustness of ion therapy treatment plans was investigated by comparison of two data sets of patients treated with and without spacer gel. A research treatment planning system for ion therapy was used for treatment plan optimization and calculation of daily dose distributions on 2 to 9 Computed Tomography (CT) studies available for each of the 19 patients. Planning and daily dose distributions were analyzed with respect to target coverage, maximal dose to the rectum (excluding 1 ml of the greatest dose; Dmax-1 ml) and the rectal volume receiving dose greater than 90% of prescribed target dose (V90 Rectum ), respectively. The application of spacer gel did substantially diminish rectum dose. Dmax-1 ml on the treatment planning CT was on average reduced from 100.0 ± 1.0% to 90.2 ± 4.8%, when spacer gel was applied. The robustness analysis performed with daily CT studies demonstrated for all analyzed patient cases that application of spacer gel results in a decrease of the daily V90 Rectum index, which calculated over all patient cases and CT studies was 10.2 ± 10.4 [ml] and 1.1 ± 2.1 [ml] for patients without and with spacer gel, respectively. The dosimetric benefit of increasing the distance between prostate and rectum using spacer gel for PC treatment with carbon ion beams has been quantified. Application of spacer gel substantially reduced rectal

  11. In Silico Study of Spacer Arm Length Influence on Drug Vectorization by Fullerene C60

    Directory of Open Access Journals (Sweden)

    Haifa Khemir

    2015-01-01

    Full Text Available This work studies theoretically the effect of spacer arm lengths on the characteristics of a fullerene C60-based nanovector. The spacer arm is constituted of a carbon chain including a variable number of methylene groups (n = 2–11. To improve the ability of the fullerene carriage, two arms are presented simultaneously through a malonyl bridge. Then the evolution of selected physicochemical parameters is monitored as a function of the spacer arm length and the angle between the two arms. We show here that while the studied characteristics are almost independent of the spacer arm length or vary monotonically with it, the dipole moment and its orientation vary periodically with the parity of the number of carbon atoms. This periodicity is related to both modules and orientations of dipole moments of the spacer arms. In the field of chemical synthesis, these results highlight the importance of theoretical calculations for the optimization of operating conditions. In the field of drug discovery, they show that theoretical calculations of the chemical properties of a drug candidate can help predict its in vivo behaviour, notably its bioavailability and biodistribution, which are known to be tightly dependent of its polarity.

  12. Air-water flooding in multirod channels: effects of spacer grids and blockages

    International Nuclear Information System (INIS)

    Cha, Jong Hee; Jun, Hyung Gil

    1993-01-01

    This paper presents the experimental results on flooding of countercurrent flow in vertical multirod channels, which consists of falling water film and upward air flow. In particular, the effects of spacer grids, with and without mixing vane, and of blockage in the multirod bundle on the behaviour of flooding were investigated. The 5 x 5 zircaloy tube bundle was used for the test section. The comparison of previous analytical models and empirical correlations with present data on flooding showed that the existing models and correlations predict much higher flooding curves. The spacer grid causes the lower flooding air flow rate to compare with the bare rod bundle. However, the mixing spacer grids need a higher flooding air flow rate for a constant liquid flow rate than the spacer grids without mixing vanes. The bundle containing blockages has the highest flooding air flow rate among the bundles with spacer grids and blokages. Empirical flooding correlations for the three types of test section have been made. (Author)

  13. Effect of different commercial feed spacers on biofouling of reverse osmosis membrane systems: A numerical study

    KAUST Repository

    Bucs, Szilard; Radu, Andrea I.; Lavric, Vasile; Vrouwenvelder, Johannes S.; Picioreanu, Cristian

    2014-01-01

    Feed spacers and hydrodynamics have been found relevant for the impact of biofouling on performance in reverse osmosis (RO) and nanofiltration (NF) membrane systems.The objectives of this study on biofouling development were to determine the impact of (i) linear flow velocity and bacterial cell load, (ii) biomass location and (iii) various feed spacer geometries as applied in practice as well as a modified geometry spacer.A three-dimensional mathematical model for biofouling of feed spacer channels including hydrodynamics, solute mass transport and biofilm formation was developed in COMSOL Multiphysics and MATLAB software.Results of this study indicate that the feed channel pressure drop increase caused by biofilm formation can be reduced by using thicker and/or modified feed spacer geometry and/or a lower flow rate in the feed channel. The increase of feed channel pressure drop by biomass accumulation is shown to be strongly influenced by the location of biomass. Results of numerical simulations are in satisfactory agreement with experimental data, indicating that this micro-scale mechanistic model is representative for practice. The developed model can help to understand better the biofouling process of spiral-wound RO and NF membrane systems and to develop strategies to reduce and control biofouling. © 2013 Elsevier B.V.

  14. Effect of different commercial feed spacers on biofouling of reverse osmosis membrane systems: A numerical study

    KAUST Repository

    Bucs, Szilard

    2014-06-01

    Feed spacers and hydrodynamics have been found relevant for the impact of biofouling on performance in reverse osmosis (RO) and nanofiltration (NF) membrane systems.The objectives of this study on biofouling development were to determine the impact of (i) linear flow velocity and bacterial cell load, (ii) biomass location and (iii) various feed spacer geometries as applied in practice as well as a modified geometry spacer.A three-dimensional mathematical model for biofouling of feed spacer channels including hydrodynamics, solute mass transport and biofilm formation was developed in COMSOL Multiphysics and MATLAB software.Results of this study indicate that the feed channel pressure drop increase caused by biofilm formation can be reduced by using thicker and/or modified feed spacer geometry and/or a lower flow rate in the feed channel. The increase of feed channel pressure drop by biomass accumulation is shown to be strongly influenced by the location of biomass. Results of numerical simulations are in satisfactory agreement with experimental data, indicating that this micro-scale mechanistic model is representative for practice. The developed model can help to understand better the biofouling process of spiral-wound RO and NF membrane systems and to develop strategies to reduce and control biofouling. © 2013 Elsevier B.V.

  15. Using cathode spacers to minimize reactor size in air cathode microbial fuel cells

    KAUST Repository

    Yang, Qiao

    2012-04-01

    Scaling up microbial fuel cells (MFCs) will require more compact reactor designs. Spacers can be used to minimize the reactor size without adversely affecting performance. A single 1.5mm expanded plastic spacer (S1.5) produced a maximum power density (973±26mWm -2) that was similar to that of an MFC with the cathode exposed directly to air (no spacer). However, a very thin spacer (1.3mm) reduced power by 33%. Completely covering the air cathode with a solid plate did not eliminate power generation, indicating oxygen leakage into the reactor. The S1.5 spacer slightly increased columbic efficiencies (from 20% to 24%) as a result of reduced oxygen transfer into the system. Based on operating conditions (1000ς, CE=20%), it was estimated that 0.9Lh -1 of air would be needed for 1m 2 of cathode area suggesting active air flow may be needed for larger scale MFCs. © 2012 Elsevier Ltd.

  16. Nonvolatile flexible organic bistable devices fabricated utilizing CdSe/ZnS nanoparticles embedded in a conducting poly N-vinylcarbazole polymer layer

    International Nuclear Information System (INIS)

    Son, Dong-Ick; Kim, Ji-Hwan; Park, Dong-Hee; Choi, Won Kook; Li, Fushan; Ham, Jung Hun; Kim, Tae Whan

    2008-01-01

    The bistable effects of CdSe/ZnS nanoparticles embedded in a conducting poly N-vinylcarbazole (PVK) polymer layer by using flexible poly-vinylidene difluoride (PVDF) and polyethylene terephthalate (PET) substrates were investigated. Transmission electron microscopy (TEM) images revealed that CdSe/ZnS nanoparticles were formed inside the PVK polymer layer. Current-voltage (I-V) measurement on the Al/[CdSe/ZnS nanoparticles+ PVK]/ITO/PVDF and Al/[CdSe/ZnS nanoparticles+ PVK ]/ITO/PET structures at 300 K showed a nonvolatile electrical bistability behavior with a flat-band voltage shift due to the existence of the CdSe/ZnS nanoparticles, indicative of trapping, storing and emission of charges in the electronic states of the CdSe nanoparticles. A bistable behavior for the fabricated organic bistable device (OBD) structures is described on the basis of the I-V results. These results indicate that OBDs fabricated by embedding inorganic CdSe/ZnS nanoparticles in a conducting polymer matrix on flexible substrates are prospects for potential applications in flexible nonvolatile flash memory devices

  17. Microbiologic Evaluation of Cotton and Polytetrafluoroethylene (PTFE) Tape as Endodontic Spacer Materials in Primary Molars An in Vivo Study.

    Science.gov (United States)

    Prabhakar, Attiguppe Ramasetty; Dixit, Kratika; Raju, O S

    PTFE tape, which is commonly used as plumber's tape is an inorganic, non-fibrous, ribbon like material. The aim of this study was to evaluate PTFE tape as endodontic spacer material and to compare it with commonly used spacer material that is cotton, in primary teeth. Seventeen children undergoing pulpectomy of lower second primary molar bilaterally were included in the study. Cotton and PTFE tape were placed as spacers on each side randomly. Samples were taken from the access cavity at baseline and after seven days to check for microbial leakage. Spacer materials were also checked for microbial contamination. The results revealed that there was a significant increase in the bacterial colony count after seven days in cotton group. The access cavities were also positive for microbial leakage in the cotton group where the spacers showed positive growth. In PTFE group only two samples showed microbial contamination of spacer and out of two only one sample showed contamination of access cavity along with spacer. Within the limitations of this study, it can be concluded that PTFE tape performed better than cotton as endodontic spacer material. Thus, PTFE tape can be recommended as an endodontic spacer material as an alternative to cotton in primary teeth.

  18. Correction method and software for image distortion and nonuniform response in charge-coupled device-based x-ray detectors utilizing x-ray image intensifier

    International Nuclear Information System (INIS)

    Ito, Kazuki; Kamikubo, Hironari; Yagi, Naoto; Amemiya, Yoshiyuki

    2005-01-01

    An on-site method of correcting the image distortion and nonuniform response of a charge-coupled device (CCD)-based X-ray detector was developed using the response of the imaging plate as a reference. The CCD-based X-ray detector consists of a beryllium-windowed X-ray image intensifier (Be-XRII) and a CCD as the image sensor. An image distortion of 29% was improved to less than 1% after the correction. In the correction of nonuniform response due to image distortion, subpixel approximation was performed for the redistribution of pixel values. The optimal number of subpixels was also discussed. In an experiment with polystyrene (PS) latex, it was verified that the correction of both image distortion and nonuniform response worked properly. The correction for the 'contrast reduction' problem was also demonstrated for an isotropic X-ray scattering pattern from the PS latex. (author)

  19. Use of XenX™, the latest ureteric occlusion device with guide wire utility: results from a prospective multicentric comparative study.

    Science.gov (United States)

    Sanguedolce, Francesco; Montanari, Emanuele; Alvarez-Maestro, Mario; Macchione, Nicola; Hruby, Stephan; Papatsoris, Athanasios; Kallidonis, Panagiotis; Villa, Luca; Honeck, Patrick; Traxer, Olivier; Greco, Francesco

    2016-11-01

    This is a prospective multicentric comparative study evaluating the performance of XenX-a new dual-purpose device for the prevention of stone fragments migration during ureteroscopic lithotripsy (URS). Between March 2014 and January 2015, 41 patients undertaking URS + XenX were matched with 41 patients undergoing standard URS. Patients included had unilateral ureteric stone(s) of 0.5-1.5 cm in maximum size. Demographics, complication rates and surgical outcomes were recorded for comparison. A Likert-like 5-grade scoring system was used for surgeons' evaluation of XenX properties. Cost analysis was performed by comparing weighted mean costs of the relevant procedures. Patients' characteristics between the two groups were comparable. Lasering time was longer for XenX group (13.59 vs. 5.17 min; p = 0.0001) whilst use of basket and need of JJ stent insertion was more frequent in control group (19.5 vs. 97.6 %; p = 0.0001 and 22 vs. 35 %; p = 0.001, respectively). Intra-operative SFR was significantly higher for XenX group (100 vs. 85.4 %; p = 0.0001), but not at 4-week follow-up, after ancillary procedures were needed in 17.1 % of the control group. Surgeons' evaluations for XenX were suboptimal for "Ease of Basketing" (2/5) and "Advancement of double J stent" (3/5). The use of XenX increased costs of procedures, but spared the costs associated to ancillary procedures and stent removals. XenX confirmed to be a safe and effective device especially for the treatment of upper ureteric tract stones; moreover, XenX may reduce the risk for the need of auxiliary procedures and for the insertion of a JJ stent.

  20. CT angiography for one-year follow-up of intracranial aneurysms treated with the WEB device: Utility in evaluating aneurysm occlusion and WEB compression at one year.

    Science.gov (United States)

    Raoult, Hélène; Eugène, François; Le Bras, Anthony; Mineur, Géraldine; Carsin-Nicol, Béatrice; Ferré, Jean-Christophe; Gauvrit, Jean-Yves

    2018-03-07

    The WEB is an innovative flow disruption device for cerebral aneurysm embolization with rapidly expanding indications. Our purpose was to evaluate the diagnostic performance of computed tomography angiography (CTA) at 1-year follow-up of aneurysms treated with the WEB. Between April 2014 and May 2016, the study prospectively included patients treated with the WEB at our institution, and followed up within 24hours by CTA and at 1year by CTA, time-of-flight magnetic resonance angiography (TOF MRA) and digital subtraction angiography (DSA). The diagnostic quality of imaging data was assessed based on the confidence index, artifacts, and WEB shape depiction. The imaging diagnostic performance was assessed using 3 criteria at 1year: aneurysm occlusion status and worsening, and WEB shape compression. Interobserver and intermodality agreement was determined by calculating κ values. The study ultimately included 16 patients (9 women, mean age 53±7.6years). CTA quality confidence was scored as 2/2, artifacts 0.4/2 and WEB shape depiction 1.9/2, superior to TOF MRA for the latter two criteria. Aneurysm occlusion was adequate in 93.7% of patients, with CTA showing excellent interobserver reproducibility and agreement with DSA on a 4-grade scale (κ=1.00), while TOF MRA yielded good reproducibility (κ=0.76) and agreement with DSA (κ=0.69). CTA also identified aneurysm occlusion worsening (43.7%) and WEB compression (81.2%) in excellent agreement with DSA (κ=0.85 and 1.00). CTA is a reproducible and reliable technique for the follow-up of aneurysms treated with the WEB device. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  1. Spacer Facial Artery Musculomucosal Flap: Simultaneous Closure of Oronasal Fistulas and Palatal Lengthening.

    Science.gov (United States)

    Lee, Jonathan Y; Alizadeh, Kaveh

    2016-01-01

    In this series, the authors describe a modification of the facial artery musculomucosal flap for oronasal fistula repair. The spacer facial artery musculomucosal flap technique is characterized by a pedicle inset into the retromolar trigone and palate, obviating a second operative stage. This was performed in 14 patients with a 5.2-cm mean fistula size. Average follow-up was 4.3 years, with one partial flap necrosis but no recurrent oronasal fistula. There was a mean decrease of 18 percent in the distance between the velum and the posterior pharyngeal wall. The spacer facial artery musculomucosal flap provides a single-stage reconstruction of oronasal fistula while lengthening the palate through a pushback mechanism. Although further study of velopharyngeal function is needed, the spacer facial artery musculomucosal flap may be beneficial for patients with a short velum and an oronasal fistula. Therapeutic, IV.

  2. [Cervical adaptation of complete cast crowns of various metal alloys, with and without die spacers].

    Science.gov (United States)

    Stephano, C B; Roselino, R F; Roselino, R B; Campos, G M

    1989-01-01

    A metallic replica from a dental preparation for crown was used to make 8 class-IV stone dies. The wax patterns for the casting of the crowns were obtained in two conditions: a) from the stone die with no spacer; and b) from the stone die with an acrylic spacer. Thus, 64 metallic crowns were casted, using 4 different alloys: DURACAST (Cu-Al), NICROCAST (Ni-Cr) and DURABOND (Ni-Cr), and gold. The casted crowns were fitted in the metallic replica and measured as to the cervical discrepance of fitting. The results showed that the use of die spacers decreases the clinical discrepancies of fitting of the casted crowns (in a statistically significant level), no matter the metallic alloy employed.

  3. Staged Custom, Intramedullary Antibiotic Spacers for Severe Segmental Bone Loss in Infected Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Atul F. Kamath

    2011-01-01

    Full Text Available Introduction. Total hip arthroplasty (THA infections with severe bone loss pose significant reconstructive challenges. We present our experience with two-stage hip reimplantation using an intramedullary, antibiotic-impregnated nail. Methods. Three patients with infected THA with severe proximal femoral bone loss (Mallory type IIIB or greater were treated using a custom antibiotic spacer. Clinical outcomes and any complications were recorded. Average followup was 49 months from final reimplantation. Results. Mean age at spacer placement (stage 1 was 53 years. The mean Harris Hip Score at final followup was 80. Two patients had asymptomatic heterotopic ossification, and one patient had a 2 cm leg-length discrepancy. Conclusions. A custom intramedullary nail antibiotic spacer is a reliable option in the staged management of the infected THA with severe proximal femoral bone loss. Benefits of this technique include limb salvage with maintenance of leg length, soft tissue tension, and functional status.

  4. Measurement of droplet dynamics across grid spacer in mist cooling of subchannel of PWR

    International Nuclear Information System (INIS)

    Lee, S.L.; Sheen, H.J.; Cho, S.K.; Issapour, I.

    1984-01-01

    An experiment was conducted of the dynamics and heat transfer of a droplet-vapor mist flow across a test grid spacer in a flow channel of 2 x 2 electrically heated simulation fuel rods. Embedded thermocouples were used to measure the rod cladding temperature and an unshielded Chromel-Alumel thermocouple was transversed in the center of the subchannel to measure the temperature of the water and steam coolant phases at various axial locations. Thermocouples were also embedded in the test grid spacer. Optical measurements of the size and velocity distributions of droplets and the velocity distribution of the superheated steam were made by special laser-Doppler anemometry techniques through quartz glass windows immediately upstream and downstream of the test grid spacer. Experiments over a range of steam and injected water flow rates and rod heat flux have been performed and some representative results and discussions are presented

  5. Measurement of grid spacer's enhanced droplet cooling under reflood condition in a PWR by LDA

    International Nuclear Information System (INIS)

    Lee, S.L.; Sheen, H.J.; Cho, S.K.; Issapour, I.; Hua, S.Q.

    1984-01-01

    Reported is an experiment designed for the measurements of grid spacer's enhanced droplet cooling under reflood condition at elevated temperatures in a steam environment. The flow channel consists of a simulated 1.60m-long pressurized water reactor (PWR) fuel rod bundle of 2 x 2 electrically heated rods. Embedded thermocouples are used to measure the rod cladding temperature at various axial levels and an unshielded Chromel-Alumel thermocouple sheathed by a small Inconel tube is traversed in the center of the subchannel to measure the temperatures of the water and steam coolant phases at various levels. The droplet dynamics across the grid spacer is directly obtained by a special laser-Doppler anemometry technique for the in situ simultaneous measurement of velocity and size of droplets through two observation windows on the test channel, one immediately before and one immediately after the grid spacer. Some results are presented and analyzed

  6. Investigation on effect of methylene spacer in holographic grating formation in eosin containing polymethacrylates

    Energy Technology Data Exchange (ETDEWEB)

    Manickasundaram, S. [Department of Chemistry, Anna University, Sardar Vallabai Patel Road, Chennai 600025 (India); Kannan, P. [Department of Chemistry, Anna University, Sardar Vallabai Patel Road, Chennai 600025 (India)]. E-mail: pakannan@annauniv.edu; Deepa, S. [Centre for Laser Technology, Department of Physics, Anna University, Chennai 600025 (India); Palanisamy, P.K. [Centre for Laser Technology, Department of Physics, Anna University, Chennai 600025 (India)

    2007-01-15

    A new series of eosin dye based poly(alkyloxymethacrylate)s was synthesized with an even number of side-chain methylene spacers by a free radical addition polymerization method for holographic optical data storage applications. These polymers were characterized by UV, IR and {sup 1}H NMR spectroscopy. The glass transition temperature and thermal stability of the polymers were investigated by DSC and TGA, respectively. As the spacer length increases in the side-chain, Tg, Tm and thermal stability of the polymers decrease, while a reverse trend was observed with film forming ability of the polymers. The optical characterization of the polymers was investigated by forming holographic grating using an Argon ion laser. The grating diffraction efficiency was found to depend not only on the concentration of polymeric film but also on the spacer length of the polymers.

  7. Investigation on effect of methylene spacer in holographic grating formation in eosin containing polymethacrylates

    International Nuclear Information System (INIS)

    Manickasundaram, S.; Kannan, P.; Deepa, S.; Palanisamy, P.K.

    2007-01-01

    A new series of eosin dye based poly(alkyloxymethacrylate)s was synthesized with an even number of side-chain methylene spacers by a free radical addition polymerization method for holographic optical data storage applications. These polymers were characterized by UV, IR and 1 H NMR spectroscopy. The glass transition temperature and thermal stability of the polymers were investigated by DSC and TGA, respectively. As the spacer length increases in the side-chain, Tg, Tm and thermal stability of the polymers decrease, while a reverse trend was observed with film forming ability of the polymers. The optical characterization of the polymers was investigated by forming holographic grating using an Argon ion laser. The grating diffraction efficiency was found to depend not only on the concentration of polymeric film but also on the spacer length of the polymers

  8. Effect of Weld Properties on the Crush Strength of the PWR Spacer Grid

    Directory of Open Access Journals (Sweden)

    Kee-nam Song

    2012-01-01

    Full Text Available Mechanical properties in a weld zone are different from those in the base material because of different microstructures. A spacer grid in PWR fuel is a structural component with an interconnected and welded array of slotted grid straps. Previous research on the strength analyses of the spacer grid was performed using base material properties owing to a lack of mechanical properties in the weld zone. In this study, based on the mechanical properties in the weld zone of the spacer grid recently obtained by an instrumented indentation technique, the strength analyses considering the mechanical properties in the weld zone were performed, and the analysis results were compared with the previous research.

  9. AA stacking, tribological and electronic properties of double-layer graphene with krypton spacer.

    Science.gov (United States)

    Popov, Andrey M; Lebedeva, Irina V; Knizhnik, Andrey A; Lozovik, Yurii E; Potapkin, Boris V; Poklonski, Nikolai A; Siahlo, Andrei I; Vyrko, Sergey A

    2013-10-21

    Structural, energetic, and tribological characteristics of double-layer graphene with commensurate and incommensurate krypton spacers of nearly monolayer coverage are studied within the van der Waals-corrected density functional theory. It is shown that when the spacer is in the commensurate phase, the graphene layers have the AA stacking. For this phase, the barriers to relative in-plane translational and rotational motion and the shear mode frequency of the graphene layers are calculated. For the incommensurate phase, both of the barriers are found to be negligibly small. A considerable change of tunneling conductance between the graphene layers separated by the commensurate krypton spacer at their relative subangstrom displacement is revealed by the use of the Bardeen method. The possibility of nanoelectromechanical systems based on the studied tribological and electronic properties of the considered heterostructures is discussed.

  10. Geometric effects of spacer grid in an annulus flow channel during reflooding period

    International Nuclear Information System (INIS)

    Cho, S.; Chun, S. Y.; Kim, B. D.; Park, J. K.; Yun, Y. J.; Baek, W. P.

    2004-01-01

    A number of studies on the reflooding phase were actively carried out from the early 70's due to its importance for the safety of the nuclear reactor. (Martini et al., 1973; Henry, 1974; Chung, 1978;) However, few studies have presented the spacer grid effect during the reflooding period. Since the grid is an obstruction in the flow passage, it causes an increased pressure drop due to form and skin friction losses. On the other hand, the spacer grid tends to increase the local wall heat transfer. The present work has been performed in a vertical annulus flow channel with various flow conditions. The objective of this paper is to evaluate the effects of a swirl-vane spacer grid on the rewetting phenomena during the reflooding phase

  11. Application of a hydrogel spacer for postoperative salvage radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Pinkawa, Michael; Schubert, Carolin; Escobar-Corral, Nuria; Holy, Richard; Eble, Michael J.

    2015-01-01

    In contrast to primary radiotherapy, no reports are available for a hydrogel spacer application in postoperative salvage radiotherapy for prostate cancer. A 77-year-old patient presented 20 years after radical prostatectomy with a digitally palpable local recurrence at the urethrovesical anastomosis (PSA 5.5 ng/ml). The hydrogel spacer (10 ml, SpaceOAR trademark) was injected between the local recurrence and rectal wall under transrectal ultrasound guidance. Treatment planning was performed with an intensity-modulated technique up to a total dose of 76 Gy in 2-Gy fractions. The same planning was performed based on computed tomography before spacer injection for comparison. The local recurrence, initially directly on the rectal wall, could be displaced more than 1 cm from the rectal wall after hydrogel injection. With a mean total dose of 76 Gy to the planning target volume, rectal wall volumes included in the 70 Gy, 60 Gy, 50 Gy isodoses were 0 cm 3 , 0 cm 3 , and 0.4 cm 3 with a spacer and 2.9 cm 3 , 4.5 cm 3 , and 6.2 cm 3 without a spacer, respectively. The patient reported rectal urgency during radiotherapy, completely resolving after the end of treatment. The PSA level was 5.4 ng/ml a week before the end of radiotherapy and dropped to 0.9 ng/ml 5 months after radiotherapy. A hydrogel spacer was successfully applied for dose-escalated radiotherapy in a patient with macroscopic local prostate cancer recurrence at the urethrovesical anastomosis to decrease the dose at the rectal wall. This option can be considered in specifically selected patients. (orig.) [de

  12. Time spans and spacers: Molecular phylogenetic explorations in the Cladophora complex (Chlorophyta) from the perspective of rDNA gene and spacer sequences

    OpenAIRE

    Bakker, Frederik Theodoor

    1995-01-01

    In this study, phylogenetic relationships among genera, species and biogeographic representatives of single Cladophora species within the Cladophorales were analyzed using rDNA gene and spacer sequences. Based on phylogenetic analysis of 18S rRNA gene sequences, the Cladophora complex is shown to be paraphyletic with respect to Cladophora species and includes several genera shich werde traditionally ascribed to the Siphonocladales (Chapter 3). ... Zie: Summary/Samenvatting

  13. Microbial fuel cells with an integrated spacer and separate anode and cathode modules

    KAUST Repository

    He, Weihua

    2016-01-01

    A new type of scalable MFC was developed based on using alternating graphite fiber brush array anode modules and dual cathode modules in order to simplify construction, operation, and maintenance of the electrodes. The modular MFC design was tested with a single (two-sided) cathode module with a specific surface area of 29 m2 m−3 based on a total liquid volume (1.4 L; 20 m2 m−3 using the total reactor volume of 2 L), and two brush anode modules. Three different types of spacers were used in the cathode module to provide structural stability, and enhance air flow relative to previous cassette (combined anode–cathode) designs: a low-profile wire spacer; a rigid polycarbonate column spacer; and a flexible plastic mesh spacer. The best performance was obtained using the wire spacer that produced a maximum power density of 1100 ± 10 mW m−2 of cathode (32 ± 0.3 W m−3 based on liquid volume) with an acetate-amended wastewater (COD = 1010 ± 30 mg L−1), compared to 1010 ± 10 mW m−2 for the column and 650 ± 20 mW m−2 for the mesh spacers. Anode potentials were unaffected by the different types of spacers. Raw domestic wastewater produced a maximum of 400 ± 8 mW m−2 under fed batch conditions (wire-spacers), which is one of the highest power densities for this fuel. Over time the maximum power was reduced to 300 ± 10 mW m−2 and 275 ± 7 mW m−2 for the two anode compartments, with only slightly less power of 250 ± 20 mW m−2 obtained under continuous flow conditions. In fixed-resistance tests, the average COD removal was 57 ± 5% at a hydraulic retention time of 8 h. These results show that this modular MFC design can both simplify reactor construction and enable relatively high power generation from even relatively dilute wastewater.

  14. Heterogeneous Diversity of Spacers within CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats)

    Science.gov (United States)

    He, Jiankui; Deem, Michael W.

    2010-09-01

    Clustered regularly interspaced short palindromic repeats (CRISPR) in bacterial and archaeal DNA have recently been shown to be a new type of antiviral immune system in these organisms. We here study the diversity of spacers in CRISPR under selective pressure. We propose a population dynamics model that explains the biological observation that the leader-proximal end of CRISPR is more diversified and the leader-distal end of CRISPR is more conserved. This result is shown to be in agreement with recent experiments. Our results show that the CRISPR spacer structure is influenced by and provides a record of the viral challenges that bacteria face.

  15. Organic light-emitting diodes with a spacer enhanced exciplex emission

    Science.gov (United States)

    Yan, Fei; Chen, Rui; Sun, Handong; Wei Sun, Xiao

    2014-04-01

    By introducing a spacer molecule into the blended exciplex emissive layer, the performance of the bulk heterojunction exciplex organic light-emitting diodes (OLEDs) was improved dramatically; the maximum luminous efficiency was enhanced by about 22% from 7.9 cd/A to 9.7 cd/A, and the luminous efficiency drop was reduced by 28% at 400 mA/cm2. Besides the suppressed annihilation of exciton, the time-resolved photoluminescence measurements indicated that the spacer enhanced the delayed fluorescence through increasing the backward intersystem crossing rate from the triplet to singlet exciplex state. This method is useful for developing high performance exciplex OLEDs.

  16. Comparison of velocity and temperature fields for two types of spacers in an annular channel

    Directory of Open Access Journals (Sweden)

    Lávička David

    2012-04-01

    Full Text Available The paper deals with measurement of flow field using a modern laser method (PIV in an annular channel of very small dimension - a fuel cell model. The velocity field was measured in several positions and plains around the spacer. The measurement was extended also to record temperatures by thermocouples soldered into stainless-steel tube wall. The measurement was focused on cooling process of the preheated fuel cell tube model, where the tube was very slowly flooded with water. Main result of the paper is comparison of two spacer's designs with respect to measured velocity and temperature fields.

  17. Automatic locking orthotic knee device

    Science.gov (United States)

    Weddendorf, Bruce C. (Inventor)

    1993-01-01

    An articulated tang in clevis joint for incorporation in newly manufactured conventional strap-on orthotic knee devices or for replacing such joints in conventional strap-on orthotic knee devices is discussed. The instant tang in clevis joint allows the user the freedom to extend and bend the knee normally when no load (weight) is applied to the knee and to automatically lock the knee when the user transfers weight to the knee, thus preventing a damaged knee from bending uncontrollably when weight is applied to the knee. The tang in clevis joint of the present invention includes first and second clevis plates, a tang assembly and a spacer plate secured between the clevis plates. Each clevis plate includes a bevelled serrated upper section. A bevelled shoe is secured to the tank in close proximity to the bevelled serrated upper section of the clevis plates. A coiled spring mounted within an oblong bore of the tang normally urges the shoes secured to the tang out of engagement with the serrated upper section of each clevic plate to allow rotation of the tang relative to the clevis plate. When weight is applied to the joint, the load compresses the coiled spring, the serrations on each clevis plate dig into the bevelled shoes secured to the tang to prevent relative movement between the tang and clevis plates. A shoulder is provided on the tang and the spacer plate to prevent overextension of the joint.

  18. Synthesis of functionalized 3D porous graphene using both ionic liquid and SiO2 spheres as ``spacers'' for high-performance application in supercapacitors

    Science.gov (United States)

    Li, Tingting; Li, Na; Liu, Jiawei; Cai, Kai; Foda, Mohamed F.; Lei, Xiaomin; Han, Heyou

    2014-12-01

    In this work, a high-capacity supercapacitor material based on functionalized three-dimensional (3D) porous graphene was fabricated by low temperature hydrothermal treatment of graphene oxide (GO) using both ionic liquid (IL) and SiO2 spheres as ``spacers''. In the synthesis, the introduction of dual ``spacers'' effectively enlarged the interspace between graphene sheets and suppressed their re-stacking. In addition, the IL also acted as a structure-directing agent playing a crucial role in inducing the formation of unique 3D architectures. Consequently, fast electron/ion transport channels were successfully constructed and numerous oxygen-containing groups on graphene sheets were effectively reserved, which had unique advantages in decreasing ion diffusion resistance and providing additional pseudocapacitance. As expected, the obtained material exhibited superior specific capacitance and rate capability compared to single ``spacer'' designed electrodes and simultaneously maintained excellent cycling stability. In particular, there was nearly no loss of its initial capacitance after 3000 cycles. In addition, we further assembled a symmetric two-electrode device using the material, which showed outstanding flexibility and low equivalent series resistance (ESR). More importantly, it was capable of yielding a maximum power density of about 13.3 kW kg-1 with an energy density of about 7.0 W h kg-1 at a voltage of 1.0 V in 1 M H2SO4 electrolyte. All these impressive results demonstrate that the material obtained by this approach is greatly promising for application in high-performance supercapacitors.In this work, a high-capacity supercapacitor material based on functionalized three-dimensional (3D) porous graphene was fabricated by low temperature hydrothermal treatment of graphene oxide (GO) using both ionic liquid (IL) and SiO2 spheres as ``spacers''. In the synthesis, the introduction of dual ``spacers'' effectively enlarged the interspace between graphene sheets

  19. Engineering of the energetic structure of the anode of organic photovoltaic devices utilizing hot-wire deposited transition metal oxide layers

    Energy Technology Data Exchange (ETDEWEB)

    Vasilopoulou, M., E-mail: mariva@imel.demokritos.gr [Institute of Nanoscience and Nanotechnology, Department of Microelectronics, National Center for Scientific Research Demokritos, POB 60228, 15310 Agia Paraskevi, Attiki (Greece); Stathopoulos, N.A.; Savaidis, S.A. [Department of Electronics, Technological and Educational Institute (TEI) of Piraeus, Petrou Ralli & Thivon, 12244 Aegaleo (Greece); Kostis, I. [Institute of Nanoscience and Nanotechnology, Department of Microelectronics, National Center for Scientific Research Demokritos, POB 60228, 15310 Agia Paraskevi, Attiki (Greece); Department of Electronics, Technological and Educational Institute (TEI) of Piraeus, Petrou Ralli & Thivon, 12244 Aegaleo (Greece); Papadimitropoulos, G. [Institute of Nanoscience and Nanotechnology, Department of Microelectronics, National Center for Scientific Research Demokritos, POB 60228, 15310 Agia Paraskevi, Attiki (Greece); Davazoglou, D., E-mail: d.davazoglou@imel.demokritos.gr [Institute of Nanoscience and Nanotechnology, Department of Microelectronics, National Center for Scientific Research Demokritos, POB 60228, 15310 Agia Paraskevi, Attiki (Greece)

    2015-09-30

    Graphical abstract: In this work we perform successful engineering of the anode of organic photovoltaics based on poly(3-hexylthiophene):[6,6]-phenyl butyric acid methyl ester blends by using metal oxide transport layers exhibiting shallow gap states which act as a barrier-free path for hole transport toward the anode. - Highlights: • Interface engineering of the anode. • Organic photovoltaics (OPVs). • Shallow gap states. • Barrier-free hole transport. • Design rules for interface engineering in OPVs. - Abstract: In this work we use hydrogen deposited molybdenum and tungsten oxides (chemically described as H:MO{sub x}x ≤ 3 where M = Mo or W) to control the energetics at the anode of bulk heterojunction (BHJ) organic photovoltaics (OPVs) based on poly(3-hexylthiophene):[6,6]-phenyl butyric acid methyl ester (P3HT:PC{sub 71}BM) blends. Significantly improved current densities and open circuit voltages were achieved as a result of improved hole transport from the P3HT highest occupied molecular orbital (HOMO) toward indium tin oxide (ITO) anode. This was attributed to the formation of shallow gap states in these oxides which are located just below the Fermi level and above the polymer HOMO and thus may act as a barrier-free path for the extraction of holes. Consequently, these states can be used for controlling the energetic structure of the anode of OPVs. By using ultraviolet photoelectron spectroscopy it was found that dependent on the deposition conditions these gap states and work function of the metal oxides may be tailored to contribute to the precise alignment of the HOMO of the organic semiconductor (OSC) with the Fermi level of the anode electrode resulting in further enhancement of the device performance.

  20. Telemedicine Physical Examination Utilizing a Consumer Device Demonstrates Poor Concordance with In-Person Physical Examination in Emergency Department Patients with Sore Throat: A Prospective Blinded Study.

    Science.gov (United States)

    Akhtar, Moneeb; Van Heukelom, Paul G; Ahmed, Azeemuddin; Tranter, Rachel D; White, Erinn; Shekem, Nathaniel; Walz, David; Fairfield, Catherine; Vakkalanka, J Priyanka; Mohr, Nicholas M

    2018-02-22

    Telemedicine allows patients to connect with healthcare providers remotely. It has recently expanded to evaluate low-acuity illnesses such as pharyngitis by using patients' personal communication devices. The purpose of our study was to compare the telemedicine-facilitated physical examination with an in-person examination in emergency department (ED) patients with sore throat. This was a prospective, observational, blinded diagnostic concordance study of patients being seen for sore throat in a 60,000-visit Midwestern academic ED. A telemedicine and a face-to-face examination were performed independently by two advanced practice providers (APP), blinded to the results of the other evaluator. The primary outcome was agreement on pharyngeal redness between the evaluators, with secondary outcomes of agreement and inter-rater reliability on 14 other aspects of the pharyngeal physical examination. We also conducted a survey of patients and providers to evaluate perceptions and preferences for sore throat evaluation using telemedicine. Sixty-two patients were enrolled, with a median tonsil size of 1.0. Inter-rater agreement (kappa) for tonsil size was 0.394, which was worse than our predetermined concordance threshold. Other kappa values ranged from 0 to 0.434, and telemedicine was best for detecting abnormal coloration of the palate and tender superficial cervical lymph nodes (anterior structures), but poor for detecting abnormal submandibular lymph nodes or asymmetry of the posterior pharynx (posterior structures). In survey responses, telemedicine was judged easier to use and more comfortable for providers than patients; however, neither patients nor providers preferred in-person to telemedicine evaluation. Telemedicine exhibited poor agreement with the in-person physical examination on the primary outcome of tonsil size, but exhibited moderate agreement on coloration of the palate and cervical lymphadenopathy. Future work should better characterize the importance of

  1. Identification of pathogenic Nocardia species by reverse line blot hybridization targeting the 16S rRNA and 16S-23S rRNA gene spacer regions.

    Science.gov (United States)

    Xiao, Meng; Kong, Fanrong; Sorrell, Tania C; Cao, Yongyan; Lee, Ok Cha; Liu, Ying; Sintchenko, Vitali; Chen, Sharon C A

    2010-02-01

    Although 16S rRNA gene sequence analysis is employed most often for the definitive identification of Nocardia species, alternate molecular methods and polymorphisms in other gene targets have also enabled species determinations. We evaluated a combined Nocardia PCR-based reverse line blot (RLB) hybridization assay based on 16S and 16S-23S rRNA gene spacer region polymorphisms to identify 12 American Type Culture Collection and 123 clinical Nocardia isolates representing 14 species; results were compared with results from 16S rRNA gene sequencing. Thirteen 16S rRNA gene-based (two group-specific and 11 species-specific) and five 16S-23S spacer-targeted (two taxon-specific and three species-specific) probes were utilized. 16S rRNA gene-based probes correctly identified 124 of 135 isolates (sensitivity, 92%) but were unable to identify Nocardia paucivorans strains (n = 10 strains) and a Nocardia asteroides isolate with a novel 16S rRNA gene sequence. Nocardia farcinica and Nocardia cyriacigeorgica strains were identified by the sequential use of an N. farcinica-"negative" probe and a combined N. farcinica/N. cyriacigeorgica probe. The assay specificity was high (99%) except for weak cross-reactivity between the Nocardia brasiliensis probe with the Nocardia thailandica DNA product; however, cross-hybridization with closely related nontarget species may occur. The incorporation of 16S-23S rRNA gene spacer-based probes enabled the identification of all N. paucivorans strains. The overall sensitivity using both probe sets was >99%. Both N. farcinica-specific 16S-23S rRNA gene spacer-directed probes were required to identify all N. farcinica stains by using this probe set. The study demonstrates the utility of a combined PCR/RLB assay for the identification of clinically relevant Nocardia species and its potential for studying subtypes of N. farcinica. Where species assignment is ambiguous or not possible, 16S rRNA gene sequencing is recommended.

  2. Synthesis of functionalized 3D porous graphene using both ionic liquid and SiO2 spheres as "spacers" for high-performance application in supercapacitors.

    Science.gov (United States)

    Li, Tingting; Li, Na; Liu, Jiawei; Cai, Kai; Foda, Mohamed F; Lei, Xiaomin; Han, Heyou

    2015-01-14

    In this work, a high-capacity supercapacitor material based on functionalized three-dimensional (3D) porous graphene was fabricated by low temperature hydrothermal treatment of graphene oxide (GO) using both ionic liquid (IL) and SiO2 spheres as "spacers". In the synthesis, the introduction of dual "spacers" effectively enlarged the interspace between graphene sheets and suppressed their re-stacking. In addition, the IL also acted as a structure-directing agent playing a crucial role in inducing the formation of unique 3D architectures. Consequently, fast electron/ion transport channels were successfully constructed and numerous oxygen-containing groups on graphene sheets were effectively reserved, which had unique advantages in decreasing ion diffusion resistance and providing additional pseudocapacitance. As expected, the obtained material exhibited superior specific capacitance and rate capability compared to single "spacer" designed electrodes and simultaneously maintained excellent cycling stability. In particular, there was nearly no loss of its initial capacitance after 3000 cycles. In addition, we further assembled a symmetric two-electrode device using the material, which showed outstanding flexibility and low equivalent series resistance (ESR). More importantly, it was capable of yielding a maximum power density of about 13.3 kW kg(-1) with an energy density of about 7.0 W h kg(-1) at a voltage of 1.0 V in 1 M H2SO4 electrolyte. All these impressive results demonstrate that the material obtained by this approach is greatly promising for application in high-performance supercapacitors.

  3. Experimental and numerical characterization of the water flow in spacer-filled channels of spiral-wound membranes

    KAUST Repository

    Bucs, Szilard; Valladares Linares, Rodrigo; Marston, Jeremy O.; Radu, Andrea I.; Vrouwenvelder, Johannes S.; Picioreanu, Cristian

    2015-01-01

    Micro-scale flow distribution in spacer-filled flow channels of spiral-wound membrane modules was determined with a particle image velocimetry system (PIV), aiming to elucidate the flow behaviour in spacer-filled flow channels. Two-dimensional water

  4. Development of an Efficient G-Quadruplex-Stabilised Thrombin-Binding Aptamer Containing a Three-Carbon Spacer Molecule

    DEFF Research Database (Denmark)

    Aaldering, Lukas J.; Poongavanam, Vasanthanathan; Langkjær, Niels

    2017-01-01

    The thrombin-binding aptamer (TBA), which shows anticoagulant properties, is one of the most studied G-quadruplex-forming aptamers. In this study, we investigated the impact of different chemical modifications such as a three-carbon spacer (spacer-C3), unlocked nucleic acid (UNA) and 3′-amino-mod...

  5. Electromagnetic force support for thermonuclear device

    International Nuclear Information System (INIS)

    Sugimoto, Makoto; Yoshida, Kiyoshi; Tachikawa, Nobuo; Omori, Junji.

    1992-01-01

    The device of the present invention certainly supports electromagnetic force exerted on toroidal magnetic field coils. That is, a pair of support members are disposed being abutted against each other between toroidal magnetic field coils disposed radially in the torus direction of a vacuum vessel. Both of the support members are connected under an insulative state by way of an insulative structural portion having an insulation key. In addition, each of the support members and each of the toroidal magnetic field coils are connected by electromagnetic force support portions having a metal taper key and a metal spacer and supporting the electromagnetic force. With such a constitution, the electromagnetic force exerted on the toroidal magnetic field coils is supported by the electromagnetic force support portion having the metal taper key and the metal spacer. As a result, stable electromagnetic force support can be attained. Further, since the insulative structural portion has the insulation key, it can be assembled easily. (I.S.)

  6. An all time low utilization of intrauterine contraceptive device as a birth spacing method--a qualitative descriptive study in district Rawalpindi, Pakistan.

    Science.gov (United States)

    Khan, Amna; Shaikh, Babar Tasneem

    2013-02-09

    Pakistan was among the leading countries in south Asia which started the family planning program in late 50s, forecasting the need to control the population. Despite this early intervention, fertility rate has declined but slower in Pakistan as compared to most other Asian countries. Pakistan has almost a stagnant contraceptive prevalence rate for more than a decade now, perhaps owing to the inadequate performance of the family planning programs. The provision and use of long term contraceptives such as IUCD has always been low (around 2%) and associated with numerous issues. Married women who want to wait before having another child, or end childbearing altogether, are not using any long term method of contraception. A descriptive qualitative study was conducted from May to July 2012, to explore and understand the perceptions of women regarding the use of IUCDs and to understand the challenges/issues at the service provider's end. Six FGDs with community women and 12 in-depth interviews were conducted with family planning providers. The data was analyzed using the Qualitative Content Analysis approach. The study revealed that the family planning clients are reluctant to use IUCDs because of a number of myths and misconceptions associated with the method. They have reservations about the provider's capability and quality of care at the facility. Private health providers are not motivated and are reluctant to provide the IUCDs because of inadequate counseling skills, lack of competence and improper supporting infrastructure. Government programs either do not have enough supplies or trained staff to promote the IUCD utilization. Besides a well-designed community awareness campaign, providers' communication and counseling skills have to be enhanced, as these are major contributing factors in IUCD acceptance. Ongoing training of all family planning service providers in IUCD insertion is very important, along with strengthening of their services.

  7. An all time low utilization of intrauterine contraceptive device as a birth spacing method- a qualitative descriptive study in district Rawalpindi, Pakistan

    Directory of Open Access Journals (Sweden)

    Khan Amna

    2013-02-01

    Full Text Available Abstract Background Pakistan was among the leading countries in south Asia which started the family planning program in late 50s, forecasting the need to control the population. Despite this early intervention, fertility rate has declined but slower in Pakistan as compared to most other Asian countries. Pakistan has almost a stagnant contraceptive prevalence rate for more than a decade now, perhaps owing to the inadequate performance of the family planning programs. The provision and use of long term contraceptives such as IUCD has always been low (around 2% and associated with numerous issues. Married women who want to wait before having another child, or end childbearing altogether, are not using any long term method of contraception. Methodology A descriptive qualitative study was conducted from May to July 2012, to explore and understand the perceptions of women regarding the use of IUCDs and to understand the challenges/issues at the service provider’s end. Six FGDs with community women and 12 in-depth interviews were conducted with family planning providers. The data was analyzed using the Qualitative Content Analysis approach. Results The study revealed that the family planning clients are reluctant to use IUCDs because of a number of myths and misconceptions associated with the method. They have reservations about the provider’s capability and quality of care at the facility. Private health providers are not motivated and are reluctant to provide the IUCDs because of inadequate counseling skills, lack of competence and improper supporting infrastructure. Government programs either do not have enough supplies or trained staff to promote the IUCD utilization. Conclusion Besides a well-designed community awareness campaign, providers’ communication and counseling skills have to be enhanced, as these are major contributing factors in IUCD acceptance. Ongoing training of all family planning service providers in IUCD insertion is very

  8. An examination of the influence of spacers on burnout in an annulus cooled by the upflow of Freon-12

    International Nuclear Information System (INIS)

    Ilic, V.

    1975-04-01

    To evaluate the spacer influence on burnout, tests were carried out in Freon-12 at 1.04 MPa (abs.) test section inlet pressure with an internally heated annulus 2743 mm long by 14.4 mm heater diameter, the outer tube (shroud) having a bore of 22.1 mm. The inner rod (heater) was located centrally to the shroud by spacers and their configuration was changed for each test. Comparison of the results with those obtained with a test section having no spacers indicated that spacers can increase burnout power up to 75 per cent, decrease it, or show no effect at all, depending on the combination of the inlet temperature and mass velocity. If the spacers were streamlined, removed from the upstream portion of the heater or relocated farther upstream from the downstream end of the heater, there was a considerably reduced effect on the test section performance. (author)

  9. A numerical approach to the simulation of one-phase and two phase reactor coolant flow around nuclear fuel spacers

    International Nuclear Information System (INIS)

    Stosic, Z.V.; Stevanovic, V.D.

    2001-01-01

    A methodology for the simulation and analysis of one-phase and two-phase coolant flows around one or a row of spacers is presented. It is based on the multidimensional two-fluid mass, momentum and energy balance equations and application of adequate turbulence models. Necessary closure laws for interfacial transfer processes are presented. The stated general approach enables simulation and analyses of reactor coolant flow around spacers on different scale levels of the rod bundle geometry: detailed modelling of coolant flow around spacers and investigation of the influence of spacer's geometry on the coolant thermal-hydraulics, as well as prediction of global thermal-hydraulic parameters within the whole rod bundle with the investigation of the influence of rows of spacers on the bulk thermal-hydraulic processes. Sample problems are included illustrating these different modelling approaches. (author)

  10. Mechanical Properties Of 3D-Structure Composites Based On Warp-Knitted Spacer Fabrics

    Directory of Open Access Journals (Sweden)

    Chen Si

    2015-06-01

    Full Text Available In this paper, the mechanical properties (compression and impact behaviours of three-dimension structure (3D-structure composites based on warp-knitted spacer fabrics have been thoroughly investigated. In order to discuss the effect of fabric structural parameters on the mechanical performance of composites, six different types of warp-knitted spacer fabrics having different structural parameters (such as outer layer structure, diameter of spacer yarn, spacer yarn inclination angle and thickness were involved for comparison study. The 3D-structure composites were fabricated based on a flexible polyurethane foam. The produced composites were characterised for compression and impact properties. The findings obtained indicate that the fabric structural parameters have strong influence on the compression and impact responses of 3D-structure composites. Additionally, the impact test carried out on the 3D-structure composites shows that the impact loads do not affect the integrity of composite structure. All the results reveal that the product exhibits promising mechanical performance and its service life can be sustained.

  11. Aerosol delivery from spacers in wheezy infants: a daily life study

    NARCIS (Netherlands)

    H.M. Janssens (Hettie); E.M. Heijnen; V.M. de Jong; W.C.J. Hop (Wim); W.P. Holland (Wim); J.C. de Jongste (Johan); H.A.W.M. Tiddens (Harm)

    2000-01-01

    textabstractThe aims of this study were to assess and compare dose delivery and dose variability of pressurized metered dose inhalers (pMDI)/spacers in wheezy infants in daily life and to investigate factors influencing aerosol delivery. In an open randomized

  12. Using cathode spacers to minimize reactor size in air cathode microbial fuel cells

    KAUST Repository

    Yang, Qiao; Feng, Yujie; Logan, Bruce E.

    2012-01-01

    generation, indicating oxygen leakage into the reactor. The S1.5 spacer slightly increased columbic efficiencies (from 20% to 24%) as a result of reduced oxygen transfer into the system. Based on operating conditions (1000ς, CE=20%), it was estimated that 0

  13. Response of an annular electrostatic probe for a right cylindrical spacer

    DEFF Research Database (Denmark)

    Johansson, Torben; MacAllister, I. W.

    2002-01-01

    The response of an annular electrostatic probe mounted in an electrode is examined with reference to a right cylindrical spacer. The study involves using the probe λ function to derive characteristic parameters. These parameters enable the response of the probe to different charge distributions...

  14. Characterization of feed channel spacer performance using geometries obtained by X-ray computed tomography

    KAUST Repository

    Haaksman, Viktor A.; Siddiqui, Amber; Schellenberg, Carsten; Kidwell, James; Vrouwenvelder, Johannes S.; Picioreanu, Cristian

    2016-01-01

    design from X-ray computed tomography (CT) scans. The method revealed that the filaments of industrial spacers have a highly variable cross-section size and shape, which impact the flow characteristics in the feed channel. The pressure drop and friction

  15. The sequence of spacers between the consensus sequences modulates the strength of procaryotic promoters

    DEFF Research Database (Denmark)

    Jensen, Peter Ruhdal; Hammer, Karin

    1998-01-01

    A library of synthetic promoters for Lactococcus lactis was constructed, in which the known consensus sequences were kept constant while the sequences of the separating spacers were randomized. The library consists of 38 promoters which differ in strength from 0.3 relative units, and up to more t......-reactors and cell factories....

  16. Exploring backbone-cation alkyl spacers for multi-cation side chain anion exchange membranes

    Science.gov (United States)

    Zhu, Liang; Yu, Xuedi; Hickner, Michael A.

    2018-01-01

    In order to systematically study how the arrangement of cations on the side chain and length of alkyl spacers between cations impact the performance of multi-cation AEMs for alkaline fuel cells, a series of polyphenylene oxide (PPO)-based AEMs with different cationic side chains were synthesized. This work resulted in samples with two or three cations in a side chain pendant to the PPO backbone. More importantly, the length of the spacer between cations varied from 3 methylene (-CH2-) (C3) groups to 8 methylene (C8) groups. The highest conductivity, up to 99 mS/cm in liquid water at room temperature, was observed for the triple-cation side chain AEM with pentyl (C5) or hexyl (C6) spacers. The multi-cation AEMs were found to have decreased water uptake and ionic conductivity when the spacer chains between cations were lengthened from pentyl (C5) or hexyl (C6) to octyl (C8) linking groups. The triple-cation membranes with pentyl (C5) or hexyl (C6) groups between cations showed greatest stability after immersion in 1 M NaOH at 80 °C for 500 h.

  17. Peri-Prosthetic Knee Infection Management: Spacers Loaded with Two or Three Antibiotic Agents.

    Science.gov (United States)

    Ortola, David Joaquin; Fenga, Domenico; Marcellino, Sandra; Rosi, Massimiliano; Centofanti, Francesco; Rosa, Michele Attilio

    2017-07-01

    The purpose of this work was to compare pre-made antibiotic-loaded spacers with two commercially available antibiotic agents and custom-made cements with three antibiotic agents added. We evaluated: (a) the validity of our procedures, (b) the control of the rate of infection in the long term, (c) complications, and (d) quality of life and patient satisfaction. A retrospective cohort study was performed on 112 consecutively treated patients between January 2010 and December 2013; 56 patients were treated with a pre-formed cement spacer (clindamycin + gentamicin), and 56 patients were treated with a spacer loaded with three antibiotic agents (clindamycin + gentamicin + vancomycin). Demographic data were collected: Classification of infection according to criteria of Cierny-Mader; microbiologic results; number of previous operations; and years of disease. Infection control or relapse after at least 18 months of follow-up was evaluated. Complications were recorded. Every patient completed the SF-36 test and Oxford Knee Score. With a follow-up of 32.87 months (standard deviation 12.04), at the end of treatment, amputation occurred in three of 112 patients because of recurrence of infection, and one patient died from other causes not related to the infection. The study population presented a rate of recurrence of infection of 2.70%. Our results suggest that a two stage re-implant with three antibiotic agents added to the spacer should be considered to avoid rescue procedures, especially in patients with multi-resistant micro-organism infections.

  18. Prediction of droplet deposition around BWR fuel spacer by FEM flow analysis

    International Nuclear Information System (INIS)

    Yamamoto, Yasushi; Morooka, Shinichi

    1997-01-01

    The critical power of the BWR fuel assembly has been remarkably increased. That increase mainly depends on the improvement of the spacer which keeps fixed gaps between fuel rods. So far, these improvements have been carried out on the basis of what developers consider to be appropriate and the results of mockup tests of the BWR fuel assembly. However, continued reliance on these approaches for the development of a higher performance fuel assembly will prove time-consuming and costly. Therefore, it is hoped that the spacer effects for the critical power can be investigated by computer simulation, and it is significantly important to develop the critical power prediction method. Direct calculation of the two-phase flow in a BWR fuel channel s still difficult. Accordingly, a new method for predicting the critical power was proposed. Our method consists of CFD (computer fluid dynamics) code based on the single-phase flow analysis method and the subchannel analysis code. To verify our method, the critical power predictions for various spacer geometries were performed. The predicted results of the critical power were compared with the experimental data. The result of the comparison showed a good agreement and the applicability of our method for various spacer geometries. (author)

  19. Phylogenetic relationships of the genus Phanerochaete inferred from the internal transcribed spacer region

    Science.gov (United States)

    Theodorus H. de Koker; Karen K. Nakasone; Jacques Haarhof; Harold H. Burdsall; Bernard J.H. Janse

    2003-01-01

    Phanerochaete is a genus of resupinate homobasidiomycetes that are saprophytic on woody debris and logs. Morphological studies in the past indicated that Phanerochaete is a heterogeneous assemblage of species. In this study the internal transcribed spacer (ITS) region of the nuclear ribosomal DNA was used to test the monophyly of the genus Phanerochaete and to infer...

  20. Device for overlapping of a column of pump compressor pipes

    Energy Technology Data Exchange (ETDEWEB)

    Sharafutdinov, I.G.; Akhmerov, M.N.; Asadullin, Kh.F.; Prokopov, O.I.

    1980-02-16

    A device is proposed for automatic overlapping of pump compressor pipes of gushing petroleum and gas wells when losses occur near the well. The objective of the invention is to increase efficiency of the overlapping of the pipe column by recharging the device directly at the hole without disassembling the head equipment. This objective is achieved as follows. The device is equipped with elastic spacers located in the channels of a ring. They are mounted with the possibility of interaction with ball catches. A drawing and description of the device are given.

  1. How type II CRISPR-Cas establish immunity through Cas1-Cas2-mediated spacer integration.

    Science.gov (United States)

    Xiao, Yibei; Ng, Sherwin; Nam, Ki Hyun; Ke, Ailong

    2017-10-05

    CRISPR (clustered regularly interspaced short palindromic repeats) and the nearby Cas (CRISPR-associated) operon establish an RNA-based adaptive immunity system in prokaryotes. Molecular memory is created when a short foreign DNA-derived prespacer is integrated into the CRISPR array as a new spacer. Whereas the RNA-guided CRISPR interference mechanism varies widely among CRISPR-Cas systems, the spacer integration mechanism is essentially identical. The conserved Cas1 and Cas2 proteins form an integrase complex consisting of two distal Cas1 dimers bridged by a Cas2 dimer. The prespacer is bound by Cas1-Cas2 as a dual-forked DNA, and the terminal 3'-OH of each 3' overhang serves as an attacking nucleophile during integration. The prespacer is preferentially integrated into the leader-proximal region of the CRISPR array, guided by the leader sequence and a pair of inverted repeats inside the CRISPR repeat. Spacer integration in the well-studied Escherichia coli type I-E CRISPR system also relies on the bacterial integration host factor. In type II-A CRISPR, however, Cas1-Cas2 alone integrates spacers efficiently in vitro; other Cas proteins (such as Cas9 and Csn2) have accessory roles in the biogenesis phase of prespacers. Here we present four structural snapshots from the type II-A system of Enterococcus faecalis Cas1 and Cas2 during spacer integration. Enterococcus faecalis Cas1-Cas2 selectively binds to a splayed 30-base-pair prespacer bearing 4-nucleotide 3' overhangs. Three molecular events take place upon encountering a target: first, the Cas1-Cas2-prespacer complex searches for half-sites stochastically, then it preferentially interacts with the leader-side CRISPR repeat, and finally, it catalyses a nucleophilic attack that connects one strand of the leader-proximal repeat to the prespacer 3' overhang. Recognition of the spacer half-site requires DNA bending and leads to full integration. We derive a mechanistic framework to explain the stepwise spacer

  2. Flouroscopically–guided transhepatic puncture for difficult TIPS re-do procedures utilizing the En Snare retrieval device: A new approach to occluded TIPS in patients with recurrent ascites

    International Nuclear Information System (INIS)

    Stambo, Glenn W.; Berlet, Matthew H.

    2012-01-01

    Portal hypertension and variceal bleeding are complications due to cirrhosis. Transjugular Intraphepatic Portosystemic shunt (TIPS) procedure is a well-established treatment for recurrent ascites and variceal bleeding related to portal hypertension. After a TIPS has been placed, the potential of TIPS occlusion or stenosis is high. A TIPS re-do procedure has been used in treatment of progressive clinical symptoms. The standard approach is via the jugular route to recannulate the TIPS shunt. Rarely, it cannot be performed from the jugular approach. Therefore, a fluoroscopically -guided transhepatic approach has been devised for these difficult situations. This case describes the use of the transhepatic route through an indwelling Viatorr covered stent utilizing an En-Snare device to help complete the TIPS re-do procedure. With this newer approach to TIPS re-do procedures, endovascular specialists can achieve TIPS patency despite difficult venous anatomical challenges and the various types of available TIPS stents presently on the market.

  3. Luminance mechanisms in green organic light-emitting devices fabricated utilizing tris(8-hydroxyquinoline)aluminum/4,7-diphenyl-1, 10-phenanthroline multiple heterostructures acting as an electron transport layer.

    Science.gov (United States)

    Choo, Dong Chul; Seo, Su Yul; Kim, Tae Whan; Jin, You Young; Seo, Ji Hyun; Kim, Young Kwan

    2010-05-01

    The electrical and the optical properties in green organic light-emitting devices (OLEDs) fabricated utilizing tris(8-hydroxyquinoline)aluminum (Alq3)/4,7-diphenyl-1,10-phenanthroline (BPhen) multiple heterostructures acting as an electron transport layer (ETL) were investigated. The operating voltage of the OLEDs with a multiple heterostructure ETL increased with increasing the number of the Alq3/BPhen heterostructures because more electrons were accumulated at the Alq3/BPhen heterointerfaces. The number of the leakage holes existing in the multiple heterostructure ETL of the OLEDs at a low voltage range slightly increased due to an increase of the internal electric field generated from the accumulated electrons at the Alq3/BPhen heterointerface. The luminance efficiency of the OLEDs with a multiple heterostructure ETL at a high voltage range became stabilized because the increase of the number of the heterointerface decreased the quantity of electrons accumulated at each heterointerface.

  4. Influence of an interpositional spacer on the behaviour of the tibiofemoral joint: a finite element study.

    Science.gov (United States)

    Checa, S; Taylor, M; New, A

    2008-10-01

    Interpositional arthroplasty is considered by many surgeons for the treatment of isolated medial compartment osteoarthritis of the knee. In this procedure, an interpositional spacer is inserted into the medial compartment of the joint with no bone resection and no mechanical fixation. Major problems such as implant dislocation, severe pain or need for revision have been reported post-operatively. In this study, the kinematics of a knee implanted with an interpositional spacer made of either polyurethane or cobalt-chrome during walking, stair ascent and squatting cycles have been predicted and compared to the normal knee using finite element analysis. In addition, articular cartilage stress histories have been examined to obtain distributions of cumulative stress, a measure of the likelihood of articular cartilage degeneration. The insertion of a polyurethane interpositional spacer in the medial side of the knee did not affect knee kinematics as compared to the normal knee, but caused an increase of articular cartilage cumulative contact stress exposures in the medial compartment of the joint. The knee implanted with the Co-Cr spacer exhibited similar trends in knee kinematics, however significantly different ranges of motion were observed during some periods of the activity cycles, specifically during the first half of the walking cycle where lower ranges of motion were predicted. In addition, higher articular cartilage cumulative contact stress exposures were observed in both compartments of the knee. In both cases, cumulative contact stress exposures of the tibial articular cartilage were more affected than those of the femoral articular cartilage. These results suggest implant material as an important parameter in the design phase of interpositional spacers.

  5. Study on natural convection in core barrel. Experimental and numerical results for band type spacer pads

    International Nuclear Information System (INIS)

    Hayashi, Kenji; Kawamata, Nobuhiro; Kamide, Hideki

    2003-03-01

    In a fast reactor an Inter-Wrapper Flow (IWF) is one of significant phenomena for decay heat removal under natural circulation condition, when a direct reactor auxiliary cooling system (DRACS) is adopted for decay heat removal system. Cold coolant provided by dipped heat exchangers (DHX) of DRACS can penetrate into the core barrel (region between the subassemblies) and it makes natural convection int he core barrel. Such IWF will depend on a spacer pad geometry of subassemblies. Water experiment, TRIF (Test Rig for Inter-wrapper Flow), was carried out for IWF in a reactor core. The test section modeled a 1/12th sector of the core and upper plenum of reactor vessel. Experimental parameters were the spacer pad geometry and flow path geometries connecting the upper plenum and core barrel. Numerical simulation using AQUA code was also performed to confirm applicability of a simulation method. An experimental series using a button type spacer pad had been carried out. Here a band type spacer pad was examined. Temperatures at subassembly wall were measured with parameter of the flow path geometries; one was a connection pipe between the upper plenum and core barrel and the other was flow hole in core former plates between the outermost subassemblies and the core barrel. It was found that these flow paths were effective to remove heat in the core in case of the band type spacer pad. A general purpose three dimensional analysis code, AQUA, was applied to the experimental analysis. Each subassembly and inter wrapper gap region were modeled by slab mesh geometry. Pressure loss coefficient at the pacer pad was set based on the geometry. The numerical simulation results were in good agreement with measured temperature profiles in the core. (author)

  6. Ion trap device

    Science.gov (United States)

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  7. Measurement and model development of the droplet diameter in rod bundles with spacer grids in the reactor core

    Energy Technology Data Exchange (ETDEWEB)

    No, Hee Cheon; Lee, Eo Hwak; Yoo, Seung Hun; Jin, Hyung Gon; Kim, In Hun [KAIST, Daejeon (Korea, Republic of)

    2010-05-15

    To understand and to predict the heat transfer between superheated steam and droplets properly during reflood phase of LBLOCA of APR1400, it is very important to measure broken droplet sizes by spacer grids. A study, therefore, has been performed to investigate droplet size in rod bundles with spacer grids and to develop a spacer grid droplet size model for safety analysis codes. Experiments were conducted with liquid droplets (SMD of 300{approx}700 {mu}m) impacting on various spacer grids at air superficial velocity of 10 and 20 m/s based on FLECHT SEASET. The test channel and the grids were heated to 150 .deg. C to prevent the formation of liquid film during tests. The spacer grids were designed refer to the Korean fuel rod bundles (Korean Standard Fuel, Plus 7) of APR1400 with various blockage area ratio and grid geometries (strap thickness, mixing vane) and about 15,000 droplets were measured at upstream and downstream of the grids in 16 tests. As a result, the measurement of broken droplet size by spacer grids with photography method is presented and the droplet size model related to spacer grids as a function of blockage area ratio is suggested in this report

  8. Effects of spacer orientations on the cake formation during membrane fouling: Quantitative analysis based on 3D OCT imaging.

    Science.gov (United States)

    Liu, Xin; Li, Weiyi; Chong, Tzyy Haur; Fane, Anthony G

    2017-03-01

    Spacer design plays an important role in improving the performance of membrane processes for water/wastewater treatment. This work focused on a fundamental issue of spacer design, i.e., investigating the effects of spacer orientations on the fouling behavior during a membrane process. A series of fouling experiments with different spacer orientation were carried out to in situ characterize the formation of a cake layer in a spacer unit cell via 3D optical coherence tomography (OCT) imaging. The cake layers formed at different times were digitalized for quantitatively analyzing the variation in the cake morphology as a function of time. In particular, the local deposition rates were evaluated to determine the active regions where the instantaneous changes in deposit thickness were significant. The characterization results indicate that varying the spacer orientation could substantially change the evolution of membrane fouling by particulate foulants and thereby result in a cake layer with various morphologies; the competition between growth and erosion at different locations would instantaneously respond to the micro-hydrodynamic environment that might change with time. This work confirms that the OCT-based characterization method is a powerful tool for exploring novel spacer design. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Influence of spacer length on heparin coupling efficiency and fibrinogen adsorption of modified titanium surfaces

    Directory of Open Access Journals (Sweden)

    Gbureck Uwe

    2007-07-01

    Full Text Available Abstract Background Chemical bonding of the drug onto surfaces by means of spacer molecules is accompanied with a reduction of the biological activity of the drug due to a constricted mobility since normally only short spacer molecule like aminopropyltrimethoxysilane (APMS are used for drug coupling. This work aimed to study covalent attachment of heparin to titanium(oxide surfaces by varying the length of the silane coupling agent, which should affect the biological potency of the drug due to a higher mobility with longer spacer chains. Methods Covalent attachment of heparin to titanium metal and TiO2 powder was carried out using the coupling agents 3-(Trimethoxysilyl-propylamine (APMS, N- [3-(Trimethoxysilylpropyl]ethylenediamine (Diamino-APMS and N1- [3-(Trimethoxy-silyl-propyl]diethylenetriamine (Triamino-APMS. The amount of bound coupling agent and heparin was quantified photometrically by the ninhydrin reaction and the tolidine-blue test. The biological potency of heparin was determined photometrically by the chromogenic substrate Chromozym TH and fibrinogen adsorption to the modified surfaces was researched using the QCM-D (Quartz Crystal Microbalance with Dissipation Monitoring technique. Results Zeta-potential measurements confirmed the successful coupling reaction; the potential of the unmodified anatase surface (approx. -26 mV shifted into the positive range (> + 40 mV after silanisation. Binding of heparin results in a strongly negatively charged surface with zeta-potentials of approx. -39 mV. The retaining biological activity of heparin was highest for the spacer molecule Triamino-APMS. QCM-D measurements showed a lower viscosity for adsorbed fibrinogen films on heparinised surfaces by means of Triamino-APMS. Conclusion The remaining activity of heparin was found to be highest for the covalent attachment with Triamino-APMS as coupling agent due to the long chain of this spacer molecule and therefore the highest mobility of the drug

  10. On the Origin of Reverse Transcriptase-Using CRISPR-Cas Systems and Their Hyperdiverse, Enigmatic Spacer Repertoires

    Directory of Open Access Journals (Sweden)

    Sukrit Silas

    2017-07-01

    Full Text Available Cas1 integrase is the key enzyme of the clustered regularly interspaced short palindromic repeat (CRISPR-Cas adaptation module that mediates acquisition of spacers derived from foreign DNA by CRISPR arrays. In diverse bacteria, the cas1 gene is fused (or adjacent to a gene encoding a reverse transcriptase (RT related to group II intron RTs. An RT-Cas1 fusion protein has been recently shown to enable acquisition of CRISPR spacers from RNA. Phylogenetic analysis of the CRISPR-associated RTs demonstrates monophyly of the RT-Cas1 fusion, and coevolution of the RT and Cas1 domains. Nearly all such RTs are present within type III CRISPR-Cas loci, but their phylogeny does not parallel the CRISPR-Cas type classification, indicating that RT-Cas1 is an autonomous functional module that is disseminated by horizontal gene transfer and can function with diverse type III systems. To compare the sequence pools sampled by RT-Cas1-associated and RT-lacking CRISPR-Cas systems, we obtained samples of a commercially grown cyanobacterium—Arthrospira platensis. Sequencing of the CRISPR arrays uncovered a highly diverse population of spacers. Spacer diversity was particularly striking for the RT-Cas1-containing type III-B system, where no saturation was evident even with millions of sequences analyzed. In contrast, analysis of the RT-lacking type III-D system yielded a highly diverse pool but reached a point where fewer novel spacers were recovered as sequencing depth was increased. Matches could be identified for a small fraction of the non-RT-Cas1-associated spacers, and for only a single RT-Cas1-associated spacer. Thus, the principal source(s of the spacers, particularly the hypervariable spacer repertoire of the RT-associated arrays, remains unknown.

  11. Similar Results in Children with Asthma for Steady State Pharmacokinetic Parameters of Ciclesonide Inhaled with or without Spacer

    Directory of Open Access Journals (Sweden)

    H. Boss

    2010-01-01

    Full Text Available Background Ciclesonide is an inhaled corticosteroid administered by a metered dose inhaler (MDI to treat bronchial asthma. After inhalation, the inactive ciclesonide is converted by esterases in the airways to active metabolite desisobutyryl-ciclesonide (des-CIC. Aim To compare the pharmacokinetic (PK parameters of des-CIC in children after administration of therapeutic dose of ciclesonide with and without spacer (AeroChamber Plus™. Methods Open-label, 3 period, cross over, repeated dose, PK study in 37 children with mild to moderate stable asthma (age: 6–11 y; body weight: 20–53 kg. During each 7-day treatment period, ciclesonide was inhaled once in the morning: A 160 μg MDI with spacer, B 80 μg MDI with spacer, and C 160 μg MDI without spacer. Serum PK parameters of ciclesonide and des-CIC were determined on Day 7 of each period. The primary PK parameters were the AUC τ and C max for des-CIC. Results Inhaling ciclesonide with spacer led to a dose proportional systemic exposure (AUC τ of des-CIC (0.316 μg*h/L for 80 μg and 0.663 μg*h/L for 160 μg. The dose-normalized systemic exposure for des-CIC (based on AUC τ was 27% higher after inhalation of ciclesonide 80 μg or 160 μg with spacer than without spacer; the corresponding C max values for des-CIC were, respectively, 63% and 55% higher with spacer. No clinically relevant abnormalities or adverse drug reactions were observed. Conclusions Inhalation of therapeutic ciclesonide dose with spacer led to a slight increase in the systemic exposure of des-CIC, which does not warrant dose adjustment.

  12. Pareto utility

    NARCIS (Netherlands)

    Ikefuji, M.; Laeven, R.J.A.; Magnus, J.R.; Muris, C.H.M.

    2013-01-01

    In searching for an appropriate utility function in the expected utility framework, we formulate four properties that we want the utility function to satisfy. We conduct a search for such a function, and we identify Pareto utility as a function satisfying all four desired properties. Pareto utility

  13. CFD analysis of pressure drop across grid spacers in rod bundles compared to correlations and heavy liquid metal experimental data

    Energy Technology Data Exchange (ETDEWEB)

    Batta, A., E-mail: batta@kit.edu; Class, A.G., E-mail: class@kit.edu

    2017-02-15

    Early studies of the flow in rod bundles with spacer grids suggest that the pressure drop can be decomposed in contributions due to flow area variations by spacer grids and frictional losses along the rods. For these shape and frictional losses simple correlations based on theoretical and experimental data have been proposed. In the OECD benchmark study LACANES it was observed that correlations could well describe the flow behavior of the heavy liquid metal loop including a rod bundle with the exception of the core region, where different experts chose different pressure-loss correlations for the losses due to spacer grids. Here, RANS–CFD simulations provided very good data compared to the experimental data. It was observed that the most commonly applied Rehme correlation underestimated the shape losses. The available correlations relate the pressure drop across a grid spacer to the relative plugging of the spacer i.e. solidity e{sub max}. More sophisticated correlations distinct between spacer grids with round or sharp leading edge shape. The purpose of this study is to (i) show that CFD is suitable to predict pressure drop across spacer grids and (ii) to access the generality of pressure drop correlations. By verification and validation of CFD results against experimental data obtained in KALLA we show (i). The generality (ii) is challenged by considering three cases which yield identical pressure drop in the correlations. First we test the effect of surface roughness, a parameter not present in the correlations. Here we compare a simulation assuming a typical surface roughness representing the experimental situation to a perfectly smooth spacer surface. Second we reverse the flow direction for the spacer grid employed in the experiments which is asymmetric. The flow direction reversal is chosen for convenience, since an asymmetric spacer grid with given blockage ratio, may result in different flow situations depending on flow direction. Obviously blockage

  14. Identification of forensically important Chrysomya (Diptera: Calliphoridae) species using the second ribosomal internal transcribed spacer (ITS2).

    Science.gov (United States)

    Nelson, Leigh A; Wallman, James F; Dowton, Mark

    2008-05-20

    The identification of forensically important blowflies of the genus Chrysomya (Diptera: Calliphoridae) may be hampered by their close morphological similarities, especially as immatures. In contrast to most previous studies, the utility of a nuclear rather than mitochondrial genetic marker was investigated to solve this problem. The second internal transcribed spacer (ITS2) of ribosomal DNA (rDNA) was amplified and sequenced from all nine Chrysomya species known from Australia. Difficulties encountered with direct sequencing of ITS2 for Chrysomya flavifrons necessitated cloning prior to sequencing for this species, which revealed a low level (0-0.23%) of intraindividual variation. Five restriction enzymes (DraI, BsaXI, BciVI, AseI and HinfI) were identified that were able to differentiate most members of the genus by polymerase chain reaction (PCR) restriction fragment length polymorphism (PCR-RFLP). The PCR-RFLP analysis revealed characteristic restriction profiles for all species except the closely related species pairs Chrysomya latifrons+Chrysomya semimetallica and Chrysomya incisuralis+Chrysomya rufifacies. Ch. incisuralis and Ch. rufifacies were able to be separated using the size differences resulting from amplification of the entire ITS region. The lack of intraspecific ITS2 sequence variation among eight Ch. incisuralis specimens was verified by the identical restriction profiles generated from these specimens. A DNA-based approach, such as PCR-RFLP, has the capacity to be useful for the identification of forensic entomological evidence in cases where morphological characters are unreliable.

  15. Efficient light emitting devices based on phosphorescent partially doped emissive layers

    KAUST Repository

    Yang, Xiaohui

    2013-05-29

    We report efficient organic light emitting devices employing an ultrathin phosphor emissive layer. The electroluminescent spectra of these devices can be tuned by introducing a low-energy emitting phosphor layer into the emission zone. Devices with the emissive layer consisting of multiple platinum-complex/spacer layer cells show a peak external quantum efficiency of 18.1%, which is among the best EQE values for platinum-complex based light emitting devices. Devices with an ultrathin phosphor emissive layer show stronger luminance decay with the operating time compared to the counterpart devices having a host-guest emissive layer.

  16. Transcriptome changes in STSV2-infected Sulfolobus islandicus REY15A undergoing continuous CRISPR spacer acquisition

    DEFF Research Database (Denmark)

    León-Sobrino, Carlos; Kot, Witold P; Garrett, Roger A

    2016-01-01

    A transcriptome study was performed on Sulfolobus islandicus REY15A actively undergoing CRISPR spacer acquisition from the crenarchaeal monocaudavirus STSV2 in rich and basal media over a 6 day period. Spacer acquisition preceded strong host growth retardation, altered transcriptional activity...... of four different CRISPR-Cas modules and changes in viral copy numbers, and with significant differences in the two media. Transcript levels of proteins involved in the cell cycle were reduced, while those of DNA replication, DNA repair, transcriptional regulation, and some antitoxin-toxin pairs...... and transposases were unchanged or enhanced. Antisense RNAs were implicated in the transcriptional regulation of adaptation and interference modules of the type I-A CRISPR-Cas system and evidence was found for the occurrence of functional coordination between the single CRISPR-Cas adaptation module...

  17. Numerical Simulation for Flow Distribution in ACE7 Fuel Assemblies affected by a Spacer Grid Deformation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jongpil; Jeong, Ji Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In spite of various efforts to understand hydraulic phenomena in a rod bundle containing deformed rods due to swelling and/or ballooning of clad, the studies for flow blockage due to spacer grid deformation have been limited. In the present work, 3D CFD analysis for flow blockage was performed to evaluate coolant flow within ACE7 fuel assemblies (FAs) containing a FA affected by a spacer grid deformation. The real geometry except for inner grids was used in the simulation and the region including inner grid was replaced by porous media. In the present work, the numerical simulation was performed to predict coolant flow within ACE7 FAs affected by a Mid grid deformation. The 3D CFD result shows that approximately 60 subchannel hydraulic diameter is required to fully recover coolant flow under normal operating condition.

  18. Synthesis, Characterization and Biological Studies of New Linear Thermally Stable Schiff Base Polymers with Flexible Spacers.

    Science.gov (United States)

    Qureshi, Farah; Khuhawar, Muhammad Yar; Jahangir, Taj Muhammad; Channar, Abdul Hamid

    2016-01-01

    Five new linear Schiff base polymers having azomethine structures, ether linkages and extended aliphatic chain lengths with flexible spacers were synthesized by polycondensation of dialdehyde (monomer) with aliphatic and aromatic diamines. The formation yields of monomer and polymers were obtained within 75-92%. The polymers with flexible spacers of n-hexane were somewhat soluble in acetone, chloroform, THF, DMF and DMSO on heating. The monomer and polymers were characterized by melting point, elemental microanalysis, FT-IR, (1)HNMR, UV-Vis spectroscopy, thermogravimetry (TG), differential thermal analysis (DTA), fluorescence emission, scanning electron microscopy (SEM) and viscosities and thermodynamic parameters measurements of their dilute solutions. The studies supported formation of the monomer and polymers and on the basis of these studies their structures have been assigned. The synthesized polymers were tested for their antibacterial and antifungal activities.

  19. Spacer layer effect and microstructure on multi-layer [NdFeB/Nb]n films

    International Nuclear Information System (INIS)

    Tsai, J.-L.; Yao, Y.-D.; Chin, T.-S.; Kronmueller, H.

    2002-01-01

    Spacer layer effect on multi-layer [NdFeB/Nb] n films has been investigated from the variation of magnetic properties and microstructure of the films. From a HRTEM cross-section view observation, the average grain size of [NdFeB/Nb] n multi-layers was controlled by both annealing temperature and thickness of NdFeB layer. Selected area diffraction pattern indicated that the structure of Nb spacer layer was amorphous. The grain size and coercivity of [NdFeB x /Nb] n films change from 50 nm and 16.7 kOe to 167 nm and 9 kOe for films with x=40 nm, n=10 and x=200 nm, n=2, respectively

  20. Effect of spacer layer on the magnetization dynamics of permalloy/rare-earth/permalloy trilayers

    International Nuclear Information System (INIS)

    Luo, Chen; Yin, Yuli; Zhang, Dong; Jiang, Sheng; Yue, Jinjin; Zhai, Ya; Du, Jun; Zhai, Hongru

    2015-01-01

    The permalloy/rare-earth/permalloy trilayers with different types (Gd and Nd) and thicknesses of spacer layer are investigated using frequency dependence of ferromagnetic resonance (FMR) measurements at room temperature, which shows different behaviors with different rare earth spacer layers. By fitting the frequency dependence of the FMR resonance field and linewidth, we find that the in-plane uniaxial anisotropy retains its value for all samples, the perpendicular anisotropy remains almost unchanged for different thickness of Gd layer but the values are tailored by different thicknesses of Nd layer. The Gilbert damping is almost unchanged with different thicknesses of Gd; however, the Gilbert damping is significantly enhanced from 8.4×10 −3 to 20.1×10 −3 with 6 nm of Nd and then flatten out when the Nd thickness rises above 6 nm

  1. Disturbance Elimination for Partial Discharge Detection in the Spacer of Gas-Insulated Switchgears

    Directory of Open Access Journals (Sweden)

    Guoming Wang

    2017-11-01

    Full Text Available With the increasing demand for precise condition monitoring and diagnosis of gas-insulated switchgears (GISs, it has become a challenge to improve the detection sensitivity of partial discharge (PD induced in the GIS spacer. This paper deals with the elimination of the capacitive component from the phase-resolved partial discharge (PRPD signal generated in GIS spacers based on discrete wavelet transform (WT. Three types of typical insulation defects were simulated using PD cells. The single PD pulses were detected and were further used to determine the optimal mother wavelet. As a result, the bior6.8 was selected to decompose the PD signal into 8 levels and the signal energy at each level was calculated. The decomposed components related with capacitive disturbance were discarded, whereas those associated with PD were de-noised by a threshold and a thresholding function. Finally, the PRPD signals were reconstructed using the de-noised components.

  2. Research on the relationship between viscoelasticity and shock isolation performance of warp knitted spacer fabrics

    Directory of Open Access Journals (Sweden)

    Jin JIANG

    2016-04-01

    Full Text Available Warp-knitted spacer fabric which is commonly used in impact protection is selected as test materials to study the relationship between viscoelasticity and the performance of shock isolation. A damping test platform is built to test different specifications of warp-knitted spacer fabric including compression elastic modulus, damping ratio and the residual impact load under different impact speed. Experimental results show that there is no clear correlation between the shock isolation performance and the viscidity or the elasticity. Accordingly, viscosity-to-elasticity ratio is proposed to characterize the relationship between viscoelasticity and shock isolation performance, and it is found that appropriate viscosity-to-elasticity ratio within a certain range can help to achieve better shock isolation performance.

  3. Nuclear reactor fuel element assembly spacer grid and method of making

    International Nuclear Information System (INIS)

    Chetter, J.

    1975-01-01

    A cellular fuel element assembly spacer grid is described which provides for resilient bracing of fuel pins in the cells of the grid by bow spring locating members projecting inside the cells of the grid to hold the fuel pins against opposed rigid stops also projecting inside the cells of the grid. The grid comprises two tiers each formed from intersecting strip members defining cells which are penetrated by the fuel pins and arranged parallel to one another but spaced apart. The bow spring locating members extend longitudinally between the two tiers and have end ferrules which are a sliding fit on locating members which extend longitudinally from the facing inner edges of the strip members forming the two tiers. The grid tiers are fabricated individually by heat bonding the intersecting strip members prior to assembling the tiers into the spacer grid. (U.S.)

  4. Effect of spacer grid mixing vanes on coolant outlet temperature distribution

    Energy Technology Data Exchange (ETDEWEB)

    Raemae, Tommi; Lahtinen, Tuukka; Brandt, Tellervo; Toppila, Timo [Fortum Power and Heat, Fortum (Finland). Nuclear Competence Center

    2012-08-15

    In Loviisa VVER-440-type NPP the coolant outlet temperature of the hot subchannel is constantly monitored during the operation. According to the authority requirement the maximum subchannel outlet temperature must not exceed the saturation temperature. Coolant temperature distribution inside the fuel assembly is affected by the efficiency of the coolant mixing. In order to enhance the coolant mixing the fuel manufacturer is introducing the additional mixing vanes on the fuel bundle spacer grids. In the paper the effect of the different mixing vane modifications is studied with computational fluid dynamics (CFD) simulation. Goal of the modelling is to find vane modifications with which sufficient mixing is reached with acceptable increase in the spacer grid pressure loss. The results of the studies are discussed in the paper. (orig.)

  5. Cost-effectiveness of fluticasone propionate administered via metered-dose inhaler plus babyhaler spacer in the treatment of asthma in preschool-aged children

    DEFF Research Database (Denmark)

    Bisgaard, H; Price, M J; Maden, Christian Nicolai

    2001-01-01

    a metered-dose inhaler and a Babyhaler (Glaxo Wellcome; Middlesex, UK) spacer device. MEASUREMENTS: Effectiveness in terms of asthma exacerbations, control of cough and wheeze symptoms, symptom-free days, overall direct costs of asthma management in Danish kroner at 1999 prices, and mean and incremental......STUDY OBJECTIVES: To evaluate the cost-effectiveness of inhaled fluticasone propionate (FP) in children aged 12 to 47 months with asthma symptoms. DESIGN: A retrospective economic analysis conducted from the perspective of the Danish health-care system, based on clinical data from a 12-week study...... cost-effectiveness ratios. RESULTS: FP, 200 microg/d, was significantly more effective than placebo treatment in terms of the proportion of exacerbation-free patients (73.7% vs 59.8%; p = 0.025) and patients experiencing a > or = 25% improvement in cough symptoms (57.9% vs 39.0%; p = 0.018). The costs...

  6. The mechanical measurement for reactor grid spacers by the laser speckle photography methd

    International Nuclear Information System (INIS)

    Yang Guoping; Chen Shitong.

    1987-01-01

    This paper describes the process of displacement, which was measured by laser speckle photography method, of reactor grid spacers during the vertical loading time. (from starting loading up to buckling). The internal forces and critical stresses were calculated by measured displacement. The effect of initial processed eccentric was considered by adding an internal force. The value of theoretical buckling load was in good agreement with the experimental result

  7. Silver-graphene oxide based plasmonic spacer for surface plasmon-coupled fluorescence emission enhancements

    Science.gov (United States)

    Badiya, Pradeep Kumar; Srinivasan, Venkatesh; Sathish Ramamurthy, Sai

    2017-06-01

    We report the application of single layered graphene oxide (SLGO) and silver decorated SLGO (Ag-SLGO) as plasmonic spacer material for obtaining enhanced fluorescence from a Rhodamine 6G (Rh6G) radiating dipole in a surface plasmon-coupled emission platform. To this end, we have decorated SLGO with biphasic silver nanoparticles using an in situ deposition technique to achieve 112-fold fluorescence enhancements.

  8. Photo-induced antiferromagnetic interlayer coupling in Fe superlattices with iron silicide spacers

    Energy Technology Data Exchange (ETDEWEB)

    Mattson, J.E.; Fullerton, E.E.; Kumar, S.; Lee, S.R.; Sowers, C.H.; Grimsditch, M.; Bader, S.D. [Argonne National Lab., IL (United States); Parker, F.T. [California Univ., San Diego, La Jolla, CA (United States). Center for Magnetic Recording Research

    1993-09-01

    Sputtered Fe/FeSi films possessing antiferromagnetic (AF) interlayer coupling at room temperature develop ferromagnetic remanence when cooled below 100K, but the AF coupling can be restored at low temperature by exposure to visible light of sufficient intensity (>10 mW/mm{sup 2}). We attribute these effects to charge carriers in the FeSi spacer layer which, when thermally or photo-generated, are capable of communicating spin information between the Fe layers.

  9. Actuator device utilizing a conductive polymer gel

    Science.gov (United States)

    Chinn, Douglas A.; Irvin, David J.

    2004-02-03

    A valve actuator based on a conductive polymer gel is disclosed. A nonconductive housing is provided having two separate chambers separated by a porous frit. The conductive polymer is held in one chamber and an electrolyte solution, used as a source of charged ions, is held in the second chamber. The ends of the housing a sealed with a flexible elastomer. The polymer gel is further provide with electrodes with which to apply an electrical potential across the gel in order to initiate an oxidation reaction which in turn drives anions across the porous frit and into the polymer gel, swelling the volume of the gel and simultaneously contracting the volume of the electrolyte solution. Because the two end chambers are sealed the flexible elastomer expands or contracts with the chamber volume change. By manipulating the potential across the gel the motion of the elastomer can be controlled to act as a "gate" to open or close a fluid channel and thereby control flow through that channel.

  10. Procedure for vibration test of the fuel rod supported by spacer grids

    International Nuclear Information System (INIS)

    Choi, Myoung Hwan; Kang, Heung Seok; Yoon, Kyung Ho; Kim, Hyung Kyu; Song, Kee Nam

    2002-07-01

    One of the methods that are used to compare and verify the supporting performance of the spacer grids developed is the vibration characteristic test. In this report there are two aims. One is of the understand of the experimental method and procedure performing the modal testing using I-DEAS TDAS module. The other is the investigation of the vibration behaviors of a dummy fuel rod supported by 8 optimized H type spacer grids. This report describes the method and procedure of modal testing to obtain the vibration characteristics such as amplitudes, natural frequencies and mode shapes of the fuel rod using a shaker, a non-contact gap sensor and an accelerometer. This report provides a test procedure in detail so that anyone can be easily understood and use the I-DEAS TDAS program. The I-DEAS TDAS program related to the modal testing has several tasks including the Modal analysis, Signal Processing et al.. This report includes model preparation to prepare the geometrical model, Signal Processing (Sine/Standard measurement) to acquire the signal, Modal analysis to obtain the frequencies and mode shapes, Correlation to analyze the relation between the test and FE analysis and Post Processing tasks. In addition, this report contains the actual test and analysis data of a dummy fuel rod in length 3847mm supported by 8 optimized H type spacer grids

  11. Design, Synthesis and Hydrolytic Behavior of Mutual Prodrugs of NSAIDs with Gabapentin Using Glycol Spacers

    Directory of Open Access Journals (Sweden)

    Hiba Najeh Alsaad

    2012-10-01

    Full Text Available The free –COOH present in NSAIDs is thought to be responsible for the GI irritation associated with all traditional NSAIDs. Exploitation of mutual prodrugs is an approach wherein the NSAID is covalently bounded to a second pharmacologically active carrier/drug with the ultimate aim of reducing the gastric irritation. In this study some NSAIDs were conjugated with gabapentin via ester bonds using glycol spacers with the expectation of reducing gastric adverse effects and obtaining synergistic analgesic effects. The kinetics of ester hydrolysis were studied in two different non enzymatic buffer solutions at pH 1.2 and 7.4, as well as in 80% human plasma using HPLC with chloroform -methanol as mobile phase. Compounds 9a–c with ethylene glycol spacers showed significant stability at buffer solutions with half lives ranging from about 8–25 h, while the underwent a reasonable plasma hydrolysis (49%–88% in 2 h. Compound 9d with a propylene glycol spacer shows a higher rate of enzymatic hydrolysis than the corresponding ethylene glycol compound 9c. The result of compounds 9a-c indicate that these compounds may be stable during their passage through the GIT until reaching the blood circulation.

  12. Insufficient sensitivity of joint aspiration during the two-stage exchange of the hip with spacers.

    Science.gov (United States)

    Boelch, Sebastian Philipp; Weissenberger, Manuel; Spohn, Frederik; Rudert, Maximilian; Luedemann, Martin

    2018-01-10

    Evaluation of infection persistence during the two-stage exchange of the hip is challenging. Joint aspiration before reconstruction is supposed to rule out infection persistence. Sensitivity and specificity of synovial fluid culture and synovial leucocyte count for detecting infection persistence during the two-stage exchange of the hip were evaluated. Ninety-two aspirations before planned joint reconstruction during the two-stage exchange with spacers of the hip were retrospectively analyzed. The sensitivity and specificity of synovial fluid culture was 4.6 and 94.3%. The sensitivity and specificity of synovial leucocyte count at a cut-off value of 2000 cells/μl was 25.0 and 96.9%. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) values were significantly higher before prosthesis removal and reconstruction or spacer exchange (p = 0.00; p = 0.013 and p = 0.039; p = 0.002) in the infection persistence group. Receiver operating characteristic area under the curve values before prosthesis removal and reconstruction or spacer exchange for ESR were lower (0.516 and 0.635) than for CRP (0.720 and 0.671). Synovial fluid culture and leucocyte count cannot rule out infection persistence during the two-stage exchange of the hip.

  13. Eddy current detection of spacers in the fuel channels of CANDU nuclear reactors

    International Nuclear Information System (INIS)

    Krause, T.W.; Schankula, J.; Sullivan, S.P.

    2002-01-01

    Garter Spring (GS) spacers in the fuel channels of CANDU nuclear reactors maintain separation between the hot pressure tube and surrounding moderator cooled calandria tube. Eddy current detection of the four GSs provides assurance that spacers are at or close to design positions and are performing their intended function of maintaining a non-zero gap between pressure tube and calandria tube. Pressure tube constrictions, resulting from relatively less diametral creep at end-of-fuel bundle locations, also produce large eddy current signals. Large constrictions, present in higher service pressure tubes, can produce signals that are 10 times larger than GS signals, reducing GS detectability to 30% in standard GS-detect probes. The introduction of field-focussing elements into the design of the standard GS detection eddy current probe has been used to recover the detectability of GS spacers by increasing the signal amplitude obtained from GSs relative to that from constrictions by a factor of 10. The work presented here compares laboratory, modelling and in-reactor measurements of GS and constriction signals obtained from the standard probe with that obtained from field-focussed eddy current probe designs. (author)

  14. Optical absorption enhancement by inserting ZnO optical spacer in plasmonic organic solar cells

    Science.gov (United States)

    N'Konou, Kekeli; Torchio, Philippe

    2018-01-01

    Optical absorption enhancement (AE) using coupled optical spacer and plasmonic effects in standard and inverted organic solar cells (OSCs) are demonstrated using the finite-difference time-domain numerical method. The influence of an added zinc oxide (ZnO) optical spacer layer inserted below the active layer in standard architecture is first theoretically investigated while the influence of varying the ZnO cathodic buffer layer thickness in inverted design is studied on AE. Then, the embedding of a square periodic array of core-shell silver-silica nanospheres (Ag@SiO2 NSs) at different positions in standard and inverted OSCs is performed while AE and short-circuit current density (Jsc) are calculated. As a result of previous combined effects, the optimized standard plasmonic OSCs present 15% and 79.45% enhancement in J over the reference with and without ZnO optical spacer layer, respectively, and a 16% increase of AE when Ag@SiO2 NSs are placed on top of the PEDOT:PSS layer. Compared to the inverted OSC reference, the plasmonic OSCs present 26% and 27% enhancement in J and AE, respectively, when the Ag@SiO2 NSs are located on top of the ZnO layer. Furthermore, the spatial position of these NSs in such OSCs is a key parameter for increasing light absorption via enhanced electromagnetic field distribution.

  15. [Identification of medicinal plant Dendrobium based on the chloroplast psbK-psbI intergenic spacer].

    Science.gov (United States)

    Yao, Hui; Yang, Pei; Zhou, Hong; Ma, Shuang-jiao; Song, Jing-yuan; Chen, Shi-lin

    2015-06-01

    In this paper, the chloroplast psbK-psbI intergenic spacers of 18 species of Dendrobium and their adulterants were amplified and sequenced, and then the sequence characteristics were analyzed. The sequence lengths of chloroplast psbK-psbI regions of Dendrobium ranged from 474 to 513 bp and the GC contents were 25.4%-27.6%. The variable sites were 71 while the informative sites were 46. The inter-specific genetic distances calculated by Kimura 2-parameter (K2P) of Dendrobium were 0.006 1-0.058 1, with an average of 0.028 4. The K2P genetic distances between Dendrobium species and Bulbophyllum odoratissimum were 0.093 2-0.120 4. The NJ tree showed that the Dendrobium species can be easily differentiated from each other and 6 samples of the inspected Dendrobium species were identified successfully through sequencing the psbK-psbI intergenic spacer. Therefore, the chloroplast psbK-psbI intergenic spacer can be used as a candidate marker to identify Dendrobium species and its adulterants.

  16. Interaction between zircaloy tube and inconel spacer grid at high temperature

    International Nuclear Information System (INIS)

    Nagase, Fumihisa; Otomo, Takashi; Uetsuka, Hiroshi; Furuta, Teruo

    1990-09-01

    In order to investigate the interaction between fuel cladding and spacer grid of the pressurized water reactor during a severe accident, isothermal reaction tests were performed at the temperature range from 1248 to 1673K. A specimen consisted of a short Zircaloy-4 cladding tube and a piece of spacer grid of Inconel-718. In the tests in an argon atmosphere, eutectic reaction between Zircaloy and Inconel was observed at the contact points at 1248K. Rapid reaction was observed at higher test temperatures. For example, in the test at 1373K for 300s, Zircaloy reacted with Inconel over the entire thickness (0.62mm) of the tube in the vicinity of the contact point. In the present tests, Zircaloy which has higher melting point than Inconel was dissolved preferentially due to eutectic formation. In the tests in an oxygen atmosphere, no eutectic reaction was observed at temperatures below 1437K. A trace of interaction was found at the contact point of specimen heated at 1573 and 1623K. However, decrease in Zircaloy thickness was not measured. The possibility of eutectic reaction between Zircaloy cladding and Inconel spacer grid seems to be quite limited when sufficient oxygen is supplied. (author)

  17. Effect of electrostatic charge in plastic spacers on the lung delivery of HFA-salbutamol in children

    DEFF Research Database (Denmark)

    Anhøj, J; Bisgaard, H; Lipworth, B J

    1999-01-01

    delivered a significantly (Pplastic spacers reduces lung dose in children by more than two-fold. This is clinically significant and the use of potentially electrostatically charged......AIMS: The effect of the electrostatic charge in plastic spacers in vivo on drug delivery to the lung of hydrofluoroalkane (HFA) salbutamol spray was studied in children. METHODS: Five children, aged 7-12 years, were included in a 3-way crossover randomised single-blind trial. Salbutamol HFA spray...... was delivered on 3 different study days from plastic spacers with mouthpiece. Pre-treatment of the spacers differed between study days: (a) Non-electrostatic 350 ml Babyhaler (coated with benzalkonium chloride) (b) New 350 ml Babyhaler (rinsed in water), and (c) New 145 ml AeroChamber (rinsed in water). Plasma...

  18. Visible light dynamical diffraction in a 1-D photonic crystal-based interferometer with an extremely thin spacer layer

    International Nuclear Information System (INIS)

    Prudnikov, I.R.

    2016-01-01

    Properties of light diffraction in a Fabry–Pérot-like interferometer composed of two 1-D photonic crystals and a nanometer-thick spacer layer are analytically investigated. It is shown that the resonant enhancement of light wave intensity in such a layer is possible because of light dynamical diffraction from the photonic crystals of the interferometer. Numerical simulations of (i) light reflectivity and transmittance curves of the interferometer having an ultra-thin spacer layer (its thickness changes from less than 1 nm to about 10 nm) and (ii) the resonant distribution of the light wave intensity in the vicinity of the layer are performed. Based on the numerical simulations, potentialities for the determination of the structural parameters (e.g., thicknesses and refraction indexes) of ultra-thin spacer films are discussed. A difference is found to appear in resonant intensity enhancements inside the ultra-thin spacer layers between s- and p-polarized light waves.

  19. Review and Comparison of simulation software for additive manufacturing process: the practical case of dipole End-Spacers

    CERN Document Server

    AUTHOR|(CDS)2271732

    2017-01-01

    Project was made to compare and benchmark simulation software for additive manufacturing. Simulations for End-spacers and HOM crab cavity were made to compare simulation results with 3D scanned data for these parts.

  20. Porosity of spacer-filled channels in spiral-wound membrane systems: Quantification methods and impact on hydraulic characterization

    KAUST Repository

    Siddiqui, Amber; Lehmann, S.; Haaksman, V.; Ogier, J.; Schellenberg, C.; van Loosdrecht, M.C.M.; Kruithof, J.C.; Vrouwenvelder, Johannes S.

    2017-01-01

    The porosity of spacer-filled feed channels influences the hydrodynamics of spiral-wound membrane systems and impacts the overall performance of the system. Therefore, an exact measurement and a detailed understanding of the impact of the feed

  1. Spacer Thickness-Dependent Electron Transport Performance of Titanium Dioxide Thick Film for Dye-Sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    Reda E. El-Shater

    2015-01-01

    Full Text Available A titanium dioxide (P25 film was deposited by cast coating as conductive photoelectrode and subsequently immersed in dye solution (N719 to fabricate the photoanode of dye-sensitized solar cells (DSSCs. A plastic spacer was used as a separation and sealant layer between the photoanode and the counter electrode. The effect of the thickness of this spacer on the transfer of electrons in the liquid electrolyte of the DSSCs was studied by means of both IV curves and electrochemical impedance. Using a spacer thickness range of 20 μm to 50 μm, efficiency ranges from 3.73% to 7.22%. The highest efficiency of 7.22% was obtained with an optimal spacer thickness of 40 μm.

  2. MO-AB-BRA-02: Modeling Nanoparticle-Eluting Spacer Degradation During Brachytherapy Application with in Situ Dose-Painting

    Energy Technology Data Exchange (ETDEWEB)

    Boateng, F [University of Massachusetts Lowell, Lowell, Massachusetts (United States); Ngwa, W [University of Massachusetts Lowell, Lowell, Massachusetts (United States); Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: Brachytherapy application with in situ dose-painting using gold nanoparticles (GNP) released from GNP-loaded brachytherapy spacers has been proposed as an innovative approach to increase therapeutic efficacy during brachytherapy. This work investigates the dosimetric impact of slow versus burst release of GNP from next generation biodegradable spacers. Methods: Mathematical models were developed based on experimental data to study the release of GNP from a spacer designed with FDA approved poly(lactic-co-glycolic acid) (PLGA) polymer. The diffusion controlled released process and PLGA polymer degradation kinetics was incorporated in the calculations for the first time. An in vivo determined diffusion coefficient was used for determining the concentration profiles and corresponding dose enhancement based on initial GNP-loading concentrations of 7 mg/g. Results: The results showed that there is significant delay before the concentration profile of GNP diffusion in the tumor is similar to that when burst release is assumed as in previous studies. For example, in the case of burst release after spacer administration, it took up to 25 days for all the GNP to be released from the spacer using diffusion controlled release process only. However, it took up to 45 days when a combined model for both diffusion and polymer degradation processes was used. Based on the tumor concentration profiles, a significant dose enhancement factor (DEF >20%), could be attained at a tumor distances of 5 mm from a spacer loaded with 10 nm GNP sizes. Conclusion: The results highlight the need to take the slow release of GNP from spacers and factors such as biodegradation of polymers into account in research development of GNP-eluting spacers for brachytherapy applications with in-situ dose-painting using gold nanoparticles. The findings suggest that I-125 may be the more appropriate for such applications given the relatively longer half-live compared to other radioisotopes like Pd-103

  3. Heat Transfer Enhancement Studies in a Circular Tube Fitted with Right-Left Helical Inserts with Spacer

    OpenAIRE

    P. K. Nagarajan; P. Sivashanmugam

    2011-01-01

    Experimental investigation of heat transfer and friction factor characteristics of circular tube fitted with 300 right-left helical screw inserts with 100 mm spacer of different twist ratio has been presented for laminar and turbulent flow.. The experimental data obtained were compared with those obtained from plain tube published data. The heat transfer coefficient enhancement for 300 RL inserts with 100 mm spacer is quite comparable with for 300 R-L inserts. Performance evalu...

  4. Distribution of CRISPR spacer matches in viruses and plasmids of crenarchaeal acidothermophiles and implications for their inhibitory mechanism

    DEFF Research Database (Denmark)

    Shah, Shiraz Ali; Hansen, Niels R; Garrett, Roger A

    2009-01-01

    Transcripts from spacer sequences within chromosomal repeat clusters [CRISPRs (clusters of regularly interspaced palindromic repeats)] from archaea have been implicated in inhibiting or regulating the propagation of archaeal viruses and plasmids. For the crenarchaeal thermoacidophiles, the chromo......Transcripts from spacer sequences within chromosomal repeat clusters [CRISPRs (clusters of regularly interspaced palindromic repeats)] from archaea have been implicated in inhibiting or regulating the propagation of archaeal viruses and plasmids. For the crenarchaeal thermoacidophiles...

  5. Diagnosis Of Persistent Infection In Prosthetic Two-Stage Exchange: PCR analysis of Sonication fluid From Bone Cement Spacers.

    Science.gov (United States)

    Mariaux, Sandrine; Tafin, Ulrika Furustrand; Borens, Olivier

    2017-01-01

    Introduction: When treating periprosthetic joint infections with a two-stage procedure, antibiotic-impregnated spacers are used in the interval between removal of prosthesis and reimplantation. According to our experience, cultures of sonicated spacers are most often negative. The objective of our study was to investigate whether PCR analysis would improve the detection of bacteria in the spacer sonication fluid. Methods: A prospective monocentric study was performed from September 2014 to January 2016. Inclusion criteria were two-stage procedure for prosthetic infection and agreement of the patient to participate in the study. Beside tissues samples and sonication, broad range bacterial PCRs, specific S. aureus PCRs and Unyvero-multiplex PCRs were performed on the sonicated spacer fluid. Results: 30 patients were identified (15 hip, 14 knee and 1 ankle replacements). At reimplantation, cultures of tissue samples and spacer sonication fluid were all negative. Broad range PCRs were all negative. Specific S. aureus PCRs were positive in 5 cases. We had two persistent infections and four cases of infection recurrence were observed, with bacteria different than for the initial infection in three cases. Conclusion: The three different types of PCRs did not detect any bacteria in spacer sonication fluid that was culture-negative. In our study, PCR did not improve the bacterial detection and did not help to predict whether the patient will present a persistent or recurrent infection. Prosthetic 2-stage exchange with short interval and antibiotic-impregnated spacer is an efficient treatment to eradicate infection as both culture- and molecular-based methods were unable to detect bacteria in spacer sonication fluid after reimplantation.

  6. Dansyl-naphthalimide dyads as molecular probes: effect of spacer group on metal ion binding properties.

    Science.gov (United States)

    Shankar, Balaraman H; Ramaiah, Danaboyina

    2011-11-17

    Interaction of a few dansyl-naphthalimide conjugates 1a-e linked through polymethylene spacer groups with various metal ions was investigated through absorption, fluorescence, NMR, isothermal calorimetric (ITC), and laser flash photolysis techniques. The characteristic feature of these dyads is that they exhibit competing singlet-singlet energy transfer (SSET) and photoinduced electron transfer (PET) processes, both of which decrease with the increase in spacer length. Depending on the spacer group, these dyads interact selectively with divalent Cu(2+) and Zn(2+) ions, as compared to other mono- and divalent metal ions. Jobs plot analysis showed that these dyads form 2:3 complexes with Cu(2+) ions, while 1:1 complexes were observed with Zn(2+) ions. The association constants for the Zn(2+) and Cu(2+) complexes were determined and are found to be in the order 10(3)-10(5) M(-1). Irrespective of the length of the spacer group, these dyads interestingly act as fluorescence ratiometric molecular probes for Cu(2+) ions by altering the emission intensity of both dansyl and naphthalimide chromophores. In contrast, only the fluorescence intensity of the naphthalimide chromophore of the lower homologues (n = 1-3) was altered by Zn(2+) ions. (1)H NMR and ITC measurements confirmed the involvement of both sulfonamide and dimethylamine groups in the complexation with Cu(2+) ions, while only the latter group was involved with Zn(2+) ions. Laser excitation of the dyads 1a-e showed formation of a transient absorption which can be attributed to the radical cation of the naphthalimide chromophore, whereas only the triplet excited state of the dyads 1a-e was observed in the presence of Cu(2+) ions. Uniquely, the complexation of 1a-e with Cu(2+) ions affects both PET and SSET processes, while only the PET process was partially inhibited by Zn(2+) ions in the lower homologues (n = 1-3) and the higher homologues exhibited negligible changes in their emission properties. Our results

  7. FY 2000 report on the trend survey of technical development of high speed/high function electronic devices such as quantum functional devices in association with the rationalization of energy utilization; 2000 nendo energy shiyo gorika ni kakawaru ryoshika kino soshi nado kosoku kokino denshi device no gijutsu kaihatsu doko chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Concerning the results of the R and D made by NEDO of superlattice devices (FY 1981-1990) and quantum functional devices (QFD) (FY 1991-2000) as high speed/high function electronic devices, this survey was aimed at investigating the trend of the newest technology to grasp the technical effects, the state of commercialization/product-making, and the future. The effects, technical subjects, etc. in the R and D of superlattice devices were succeeded to the R and D of QFD as the succeeding project. Here, therefore, the paper arranged the outlook of the commercialization/product-making in relation to the R and D of QFD and the future R and D subjects. In the R and D, features of QFD as target were made clear. The commercialization is limited to Motorola's QMMIC, Fujitsu's RHET, etc. As to the other R and D items, subjects of the technical development to be implemented toward the commercialization just became clear. The subject is the heightening of micro (nano meter) processing technology. The important subject, in particular, is compatibility of the heightening of micro processing and the improvement of throughput. (NEDO)

  8. Optical properties of white organic light-emitting devices fabricated utilizing a mixed CaAl12O19:Mn4+ and Y3Al5O12:Ce3+ color conversion layer.

    Science.gov (United States)

    Jeong, H S; Kim, S H; Lee, K S; Jeong, J M; Yoo, T W; Kwon, M S; Yoo, K H; Kim, T W

    2013-06-01

    White organic light-emitting devices (OLEDs) were fabricated by combining a blue OLED with a color conversion layer made of mixed Y3Al5O12:Ce3+ green and Ca2AlO19:Mn4+ red phosphors. The X-ray diffraction patterns showed that Ce3+ ions in the Y3Al5O12:Ce3+ phosphors completely substituted for the Y3+ ions and the Mn4+ ions in the CaAl12O19:Mn4+ phosphors completely substituted for the Ca2+ ions. Electroluminescence spectra at 11 V for the OLEDs fabricated utilizing a color conversion layer showed that the Commission Internationale de l'Eclairage coordinates for the Y3Al5O12:Ce3+ and CaAl12O19:Mn4+ phosphors mixed at the ratio of 1:5 and 1:10 were (0.31, 0.34) and (0.32, 0.37), respectively, indicative of a good white color.

  9. Spacer length impacts the efficacy of targeted docetaxel conjugates in prostate-specific membrane antigen expressing prostate cancer.

    Science.gov (United States)

    Peng, Zheng-Hong; Sima, Monika; Salama, Mohamed E; Kopečková, Pavla; Kopeček, Jindřich

    2013-12-01

    Combination of targeted delivery and controlled release is a powerful technique for cancer treatment. In this paper, we describe the design, synthesis, structure validation and biological properties of targeted and non-targeted N-(2-hydroxypropyl)methacrylamide (HPMA) copolymer-docetaxel conjugates. Docetaxel (DTX) was conjugated to HPMA copolymer via a tetrapeptide spacer (-GFLG-). 3-(1,3-dicarboxypropyl)-ureido]pentanedioic acid (DUPA) was used as the targeting moiety to actively deliver DTX for treatment of Prostate-Specific Membrane Antigen (PSMA) expressing prostate cancer. Short and long spacer DUPA monomers were prepared, and four HPMA copolymer--DTX conjugates (non-targeted, two targeted with short spacer of different molecular weight and targeted with long spacer) were prepared via Reversible Addition-Fragmentation Chain Transfer (RAFT) copolymerization. Following confirmation of PSMA expression on C4-2 cell line, the DTX conjugates' in vitro cytotoxicity was tested against C4-2 tumor cells and their anticancer efficacies were assessed in nude mice bearing s.c. human prostate adenocarcinoma C4-2 xenografts. The in vivo results show that the spacer length between targeting moieties and HPMA copolymer backbone can significantly affect the treatment efficacy of DTX conjugates against C4-2 tumor bearing nu/nu mice. Moreover, histological analysis indicated that the DUPA-targeted DTX conjugate with longer spacer had no toxicity in major organs of treated mice.

  10. The thermalhydraulics of a pin bundle with a helical wire wrap spacer. Modeling and qualification for a new sub-assembly concept

    International Nuclear Information System (INIS)

    Valentin, B.

    2000-01-01

    For the sub-assembly composed by an hexcan and a pin bundle with an helical wire wrap spacer, the calculation of the maximum clad temperatures, with the design code CADET, imposed to correctly evaluate the heat and mass transfers due to the helical wire. The models use theoretical and experimental arguments which are presented after a brief description of the hydraulic behavior of a such bundle. The design of a new sub-assembly concept, in the framework of high plutonium consumption in fast reactor projects needs to qualify tile models from RAPSODIE, PHENIX and SUPER-PHENIX programs. The qualification program, which could be used, is described. the approach is notably comparative for the hydraulic fields and the past experimental results will be useful. Another approach is briefly presented. It uses a multidimensional code (TRIO) which solves Navier-Stokes equations. The utility and the limits of a such method are described. (author)

  11. Effect of the ZnS shell layer on the charge storage capabilities of organic bistable memory devices fabricated utilizing CuInS2–ZnS core–shell quantum dots embedded in a poly(methylmethacrylate) layer

    International Nuclear Information System (INIS)

    Yun, Dong Yeol; Kim, Tae Whan; Kim, Sang Wook

    2013-01-01

    The electrical characteristics of organic bistable memory devices (OBDs) fabricated utilizing CuInS 2 (CIS) core or CIS–ZnS core–shell quantum dots (QDs) embedded in a poly(methylmethacrylate) (PMMA) layer on indium–tin-oxide (ITO) coated glass substrates were investigated. X-ray photoelectron spectroscopy spectra demonstrated that the stoichiometries of the QDs embedded in a PMMA layer were CIS or CIS–ZnS QDs. Current–voltage measurements on Al/CIS or CIS–ZnS QDs embedded in PMMA layer/ITO glass devices at 300 K showed current bistabilities. The maximum ON/OFF current ratios of the OBDs with CIS or CIS–ZnS QDs were approximately 1 × 10 3 and 1 × 10 5 , respectively. The retention number of ON and OFF states was measured by 1 × 10 5 . The memory mechanisms of the OBDs with CIS or CIS–ZnS QDs are described on the basis of the experimental results. - Highlights: • Organic bistable devices utilizing nanocomposites were fabricated. • Current–voltage results on organic bistable devices showed current bistabilities. • Maximum ON/OFF current ratio of the device with core–shell quantum dots was 1 × 10 5 . • Retention number of the device with core–shell quantum dots was 1 × 10 5

  12. WE-FG-BRA-02: Docetaxel Eluting Brachytherapy Spacers for Local Chemo-Radiation Therapy in Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Belz, J [Northeastern University, Boston, MA (United States); Kumar, R; Sridhar, S [Northeastern University & Dana Farber Cancer Institute, Boston, MA (United States); Makrigiorgos, G; Nguyen, P [Dana Farber Cancer Institute, Boston, MA (United States); D’Amico, A [Brigham & Women’s Hospital, Boston, MA (United States); Cormack, R [Harvard Medical School, Boston, MA (United States)

    2016-06-15

    Purpose: We propose an innovative combinatorial treatment strategy of Local ChemoRadiation Therapy (LCRT) using a sustained drug delivery platform in the form of a spacer to locally radio-sensitize the prostate with Docetaxel (DTX) enabling a synergistic cure with the use of lower radiation doses. These biodegradable spacers are physically similar to the inert spacers routinely used in prostate brachytherapy but are now loaded with formulations of DTX. Methods: Spacers were loaded with ∼500µg Docetaxel (DTX) for prostate cancer studies. The implants were characterized in vitro using SEM and HPLC. The release kinetic studies were carried out in buffer (pH 6.0) at 37°C. Subcutaneous PC3 tumors were xenografted in nude mice. Prostate cancer studies were done with and without radiation using SARRP at 5Gy, 10Gy, and 15Gy. Drug-loaded implants were injected once intratumorally using an 18G brachytherapy needle. Results: The release study in vitro showed a highly sustained release for multiple weeks at therapeutically relevant doses. The monotherapy with local DTX spacer showed sustained tumor inhibition compared to empty implants and an equivalent DTX dose given systemically. At 40 days, 89% survival was observed for mice treated with DTX implants compared with 0% in all other treatment groups. The combined treatment with local DTX spacer and radiation (10Gy) showed the highest degree of tumor suppression (significant tumor growth inhibition by day 90). The control mice showed continuous tumor growth and were scarified by day 56. Groups of mice treated with DTX-spacer or radiation alone showed initial tumor suppression but growth continued after day 60. A larger experiment is ongoing. Conclusion: This approach provides localized delivery of the chemotherapeutic sensitizer directly to the tumor and avoids the toxicities associated with both brachytherapy and current systemic delivery of docetaxel. Sustained release of DTX is an effective chemotherapy option alone or

  13. Computational model for turbulent flow around a grid spacer with mixing vane

    International Nuclear Information System (INIS)

    Tsutomu Ikeno; Takeo Kajishima

    2005-01-01

    Turbulent mixing coefficient and pressure drop are important factors in subchannel analysis to predict onset of DNB. However, universal correlations are difficult since these factors are significantly affected by the geometry of subchannel and a grid spacer with mixing vane. Therefore, we propose a computational model to estimate these factors. Computational model: To represent the effect of geometry of grid spacer in computational model, we applied a large eddy simulation (LES) technique in couple with an improved immersed-boundary method. In our previous work (Ikeno, et al., NURETH-10), detailed properties of turbulence in subchannel were successfully investigated by developing the immersed boundary method in LES. In this study, additional improvements are given: new one-equation dynamic sub-grid scale (SGS) model is introduced to account for the complex geometry without any artificial modification; the higher order accuracy is maintained by consistent treatment for boundary conditions for velocity and pressure. NUMERICAL TEST AND DISCUSSION: Turbulent mixing coefficient and pressure drop are affected strongly by the arrangement and inclination of mixing vane. Therefore, computations are carried out for each of convolute and periodic arrangements, and for each of 30 degree and 20 degree inclinations. The difference in turbulent mixing coefficient due to these factors is reasonably predicted by our method. (An example of this numerical test is shown in Fig. 1.) Turbulent flow of the problem includes unsteady separation behind the mixing vane and vortex shedding in downstream. Anisotropic distribution of turbulent stress is also appeared in rod gap. Therefore, our computational model has advantage for assessing the influence of arrangement and inclination of mixing vane. By coarser computational mesh, one can screen several candidates for spacer design. Then, by finer mesh, more quantitative analysis is possible. By such a scheme, we believe this method is useful

  14. Diversity in a Polymicrobial Community Revealed by Analysis of Viromes, Endolysins and CRISPR Spacers.

    Directory of Open Access Journals (Sweden)

    Michelle Davison

    Full Text Available The polymicrobial biofilm communities in Mushroom and Octopus Spring in Yellowstone National Park (YNP are well characterized, yet little is known about the phage populations. Dominant species, Synechococcus sp. JA-2-3B'a(2-13, Synechococcus sp. JA-3-3Ab, Chloroflexus sp. Y-400-fl, and Roseiflexus sp. RS-1, contain multiple CRISPR-Cas arrays, suggesting complex interactions with phage predators. To analyze phage populations from Octopus Spring biofilms, we sequenced a viral enriched fraction. To assemble and analyze phage metagenomic data, we developed a custom module, VIRITAS, implemented within the MetAMOS framework. This module bins contigs into groups based on tetranucleotide frequencies and CRISPR spacer-protospacer matching and ORF calling. Using this pipeline we were able to assemble phage sequences into contigs and bin them into three clusters that corroborated with their potential host range. The virome contained 52,348 predicted ORFs; some were clearly phage-like; 9319 ORFs had a recognizable Pfam domain while the rest were hypothetical. Of the recognized domains with CRISPR spacer matches, was the phage endolysin used by lytic phage to disrupt cells. Analysis of the endolysins present in the thermophilic cyanophage contigs revealed a subset of characterized endolysins as well as a Glyco_hydro_108 (PF05838 domain not previously associated with sequenced cyanophages. A search for CRISPR spacer matches to all identified phage endolysins demonstrated that a majority of endolysin domains were targets. This strategy provides a general way to link host and phage as endolysins are known to be widely distributed in bacteriophage. Endolysins can also provide information about host cell wall composition and have the additional potential to be used as targets for novel therapeutics.

  15. PairWise Neighbours database: overlaps and spacers among prokaryote genomes

    Directory of Open Access Journals (Sweden)

    Garcia-Vallvé Santiago

    2009-06-01

    Full Text Available Abstract Background Although prokaryotes live in a variety of habitats and possess different metabolic and genomic complexity, they have several genomic architectural features in common. The overlapping genes are a common feature of the prokaryote genomes. The overlapping lengths tend to be short because as the overlaps become longer they have more risk of deleterious mutations. The spacers between genes tend to be short too because of the tendency to reduce the non coding DNA among prokaryotes. However they must be long enough to maintain essential regulatory signals such as the Shine-Dalgarno (SD sequence, which is responsible of an efficient translation. Description PairWise Neighbours is an interactive and intuitive database used for retrieving information about the spacers and overlapping genes among bacterial and archaeal genomes. It contains 1,956,294 gene pairs from 678 fully sequenced prokaryote genomes and is freely available at the URL http://genomes.urv.cat/pwneigh. This database provides information about the overlaps and their conservation across species. Furthermore, it allows the wide analysis of the intergenic regions providing useful information such as the location and strength of the SD sequence. Conclusion There are experiments and bioinformatic analysis that rely on correct annotations of the initiation site. Therefore, a database that studies the overlaps and spacers among prokaryotes appears to be desirable. PairWise Neighbours database permits the reliability analysis of the overlapping structures and the study of the SD presence and location among the adjacent genes, which may help to check the annotation of the initiation sites.

  16. The CRISPRdb database and tools to display CRISPRs and to generate dictionaries of spacers and repeats

    Directory of Open Access Journals (Sweden)

    Vergnaud Gilles

    2007-05-01

    Full Text Available Abstract Background In Archeae and Bacteria, the repeated elements called CRISPRs for "clustered regularly interspaced short palindromic repeats" are believed to participate in the defence against viruses. Short sequences called spacers are stored in-between repeated elements. In the current model, motifs comprising spacers and repeats may target an invading DNA and lead to its degradation through a proposed mechanism similar to RNA interference. Analysis of intra-species polymorphism shows that new motifs (one spacer and one repeated element are added in a polarised fashion. Although their principal characteristics have been described, a lot remains to be discovered on the way CRISPRs are created and evolve. As new genome sequences become available it appears necessary to develop automated scanning tools to make available CRISPRs related information and to facilitate additional investigations. Description We have produced a program, CRISPRFinder, which identifies CRISPRs and extracts the repeated and unique sequences. Using this software, a database is constructed which is automatically updated monthly from newly released genome sequences. Additional tools were created to allow the alignment of flanking sequences in search for similarities between different loci and to build dictionaries of unique sequences. To date, almost six hundred CRISPRs have been identified in 475 published genomes. Two Archeae out of thirty-seven and about half of Bacteria do not possess a CRISPR. Fine analysis of repeated sequences strongly supports the current view that new motifs are added at one end of the CRISPR adjacent to the putative promoter. Conclusion It is hoped that availability of a public database, regularly updated and which can be queried on the web will help in further dissecting and understanding CRISPR structure and flanking sequences evolution. Subsequent analyses of the intra-species CRISPR polymorphism will be facilitated by CRISPRFinder and the

  17. [Electronic Device for Retinal and Iris Imaging].

    Science.gov (United States)

    Drahanský, M; Kolář, R; Mňuk, T

    This paper describes design and construction of a new device for automatic capturing of eye retina and iris. This device has two possible ways of utilization - either for biometric purposes (persons recognition on the base of their eye characteristics) or for medical purposes as supporting diagnostic device. eye retina, eye iris, device, acquisition, image.

  18. Influence of the boundary conditions on heat and mass transfer in spacer-filled channels

    Science.gov (United States)

    Ciofalo, M.; La Cerva, M. F.; Di Liberto, M.; Tamburini, A.

    2017-11-01

    The purpose of this study is to discuss some problems which arise in heat or mass transfer in complex channels, with special reference to the spacer-filled channels adopted in membrane processes. Among the issues addressed are the consistent definition of local and mean heat or mass transfer coefficients; the influence of the wall boundary conditions; the influence of one-side versus two-side heat/mass transfer. Most of the results discussed were obtained by finite volume CFD simulations concerning heat transfer in Membrane Distillation or mass transfer in Electrodialysis and Reverse Electrodialysis, but many of the conclusions apply also to different processes involving geometrically complex channels

  19. Hydrodynamics around a spacer of a VVER-440 fuel rod bundle

    International Nuclear Information System (INIS)

    Mayer, G.; Hazi, G.; Kavran, P.

    2004-01-01

    Recently, an intensive research has been started in our institute, focusing on the hydrodynamics of fuel rod bundles. Numerical computations have been planed to be carried out in a three level bottom-up hierarchy, using direct numerical simulation, large eddy simulation and Reynolds averaged Navier-Stokes approach. Here, we give a description of the numerical method applied for direct numerical and large eddy simulation. We present some preliminary results obtained by the simulation of the flow around a spacer of a VVER-440 fuel rod bundle. (author)

  20. Modal properties of the flexural vibrating package of rods linked by spacer grids

    Directory of Open Access Journals (Sweden)

    Zeman V.

    2011-06-01

    Full Text Available The paper deals with the modelling and modal analysis of the large package of identical parallel rods linked by transverse springs (spacer grids placed on several level spacings. The rod discretization by finite element method is based on Rayleigh beam theory. For the cyclic and central symmetric package of rods (such as fuel rods in nuclear fuel assembly the system decomposition on the identical revolved rod segments was applied. A modal synthesis method with condensation is used for modelling of the whole system. The presented method is the first step for modelling the nuclear fuel assembly vibration caused by excitation determined by the support plate motion of the reactor core.

  1. Expedient Protocols for the Installation of Pyrimidine Based Privileged Templates on 2-Position of Pyrrolo[2,1-c][1,4]-benzodiazepine Nucleus Linked Through a p-phenoxyl Spacer

    Directory of Open Access Journals (Sweden)

    Anshu Agarwal

    2012-01-01

    Full Text Available Exceedingly facile single step expedient protocols based on the versatility and reactivity of corresponding intermediates : [2-(dimethylaminomethylene ketone] (5 and chalcone (6, derived from 2-(p-acetyl phenoxyl substituted analogue of pyrrolo[2,1-c][1,4]-benzodiazepine (4, have been developed to provide an easy installation of the pyrimidine based privileged templates at 2-position of pyrrolo[2,1-c][1,4]-benzodiazepine through a p-phenoxyl spacer, by utilizing the synthetic strategy depicted in schemes-1 and 2.

  2. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  3. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  4. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  5. Preclinical investigations towards the first spacer gel application in prostate cancer treatment during particle therapy at HIT

    International Nuclear Information System (INIS)

    Ruciński, Antoni; Parodi, Katia; Jäkel, Oliver; Haberer, Thomas; Bauer, Julia; Campbell, Patrick; Brons, Stephan; Unholtz, Daniel; Habl, Gregor; Herfarth, Klaus; Debus, Jürgen; Bert, Christoph

    2013-01-01

    The application of spacer gel represents a promising approach to reliably spare the rectal frontal wall during particle therapy (IJROBP 76:1251-1258, 2010). In order to qualify the spacer gel for the clinical use in particle therapy, a variety of measurements were performed in order to ensure the biological compatibility of the gel, its physical stability during and after the irradiation, and a proper definition of the gel in terms of the Hounsfield Unit (HU) values for the treatment planning system. The potential for the use of the spacer gel for particle therapy monitoring with off-line Positron Emission Tomography (PET) was also investigated. The spacer gel implanted to the prostate patient in direct neighbourhood to the clinical target volume does not interfere with the particle therapy treatment planning procedure applied at Heidelberg Ion Beam Therapy Centre (HIT). The performed measurements show that Bragg-peak position of the particles can be properly predicted on the basis of computed tomography imaging with the treatment planning system used at HIT (measured water equivalent path length of 1.011 ±0.011 (2σ), measured Hounsfield Unit of 28.9 ±6.1 (2σ)). The spacer gel samples remain physically unchanged after irradiation with a dose exceeding the therapeutic dose level. The independently measured Bragg-Peak position does not change within the time interval of 10 weeks. As a result of the presented experiments, the first clinical application of spacer gel implant during prostate cancer treatment with carbon ions and protons was possible at HIT in 2012. The reported pre-clinical investigations demonstrate that use of spacer gel is safe in particle therapy in presence of therapy target motion and patient positioning induced particle range variations. The spacer gel injected between prostate and rectum enlarge the distance between both organs, which is expected to clinically significantly decrease the undesirable exposure of the most critical organ at risk

  6. Social group utility maximization

    CERN Document Server

    Gong, Xiaowen; Yang, Lei; Zhang, Junshan

    2014-01-01

    This SpringerBrief explains how to leverage mobile users' social relationships to improve the interactions of mobile devices in mobile networks. It develops a social group utility maximization (SGUM) framework that captures diverse social ties of mobile users and diverse physical coupling of mobile devices. Key topics include random access control, power control, spectrum access, and location privacy.This brief also investigates SGUM-based power control game and random access control game, for which it establishes the socially-aware Nash equilibrium (SNE). It then examines the critical SGUM-b

  7. Single-Stage Treatment of Osteomyelitis for Digital Salvage by Using an Antibiotic-Eluting, Methylmethacrylate Joint-Spanning Spacer.

    Science.gov (United States)

    Aimé, Victoria L; Kidwell, John T; Webb, Leland H

    2017-06-01

    Osteomyelitis of the digit is a challenging problem that can result in amputation. We describe 13 cases of osteomyelitis involving bones of the hand managed with a novel technique. We reviewed records of 12 patients (13 digits) who had joint-spanning, antibiotic-eluting (tobramycin or vancomycin), methylmethacrylate spacers placed as definitive, single-stage treatment for digital osteomyelitis. The primary outcome was digit salvage. Secondary outcomes were infection eradication (no recurrence at 3 months) and spacer removal. Patients were followed up until the infection resolved (ie, no cutaneous signs of infection, including pain, erythema, or swelling). At a mean of 24 months, 10 of 13 infections had successful one-stage treatment. One patient required a second operation to revise a soft tissue flap but the spacer remained in place. Two spacers were removed because of malalignment. An antibiotic-eluting methylmethacrylate spacer is an innovative treatment for digital osteomyelitis. In 12 consecutive patients (13 digits), we successfully salvaged the digit. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. The Construction of Chimeric T-Cell Receptor with Spacer Base of Modeling Study of VHH and MUC1 Interaction

    Directory of Open Access Journals (Sweden)

    Nazanin Pirooznia

    2011-01-01

    Full Text Available Adaptive cell immunotherapy with the use of chimeric receptors leads to the best and most specific response against tumors. Chimeric receptors consist of a signaling fragment, extracellular spacer, costimulating domain, and an antibody. Antibodies cause immunogenicity; therefore, VHH is a good replacement for ScFv in chimeric receptors. Since peptide sequences have an influence on chimeric receptors, the effect of peptide domains on each other's conformation were investigated. CD3Zeta, CD28, VHH and CD8α, and FcgIIα are used as signaling moieties, costimulating domain, antibody, and spacers, respectively. To investigate the influence of the ligation of spacers on the conformational structure of VHH, models of VHH were constructed. Molecular dynamics simulation was run to study the influence of the presence of spacers on the conformational changes in the binding sites of VHH. Root mean square deviation and root mean square fluctuation of critical segments in the binding site showed no noticeable differences with those in the native VHH. Results from molecular docking revealed that the presence of spacer FcgIIα causes an increasing effect on VHH with MUC1 interaction. Each of the constructs was transformed into the Jurkat E6.1. Expression analysis and evaluation of their functions were examined. The results showed good expression and function.

  9. Comparative study of the contribution of various PWR spacer grid components to hydrodynamic and wall pressure characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharjee, Saptarshi, E-mail: saptarshi.bhattacharjee@outlook.com [Alternative Energies and Atomic Energy Commission (CEA) – Cadarache, DEN/DTN/STCP/LHC, 13108 Saint Paul lez Durance Cedex (France); Laboratoire de Mécanique, Modélisation et Procédés Propres (M2P2), UMR7340 CNRS, Aix-Marseille Université, Centrale Marseille, 13451 Marseille Cedex (France); Ricciardi, Guillaume [Alternative Energies and Atomic Energy Commission (CEA) – Cadarache, DEN/DTN/STCP/LHC, 13108 Saint Paul lez Durance Cedex (France); Viazzo, Stéphane [Laboratoire de Mécanique, Modélisation et Procédés Propres (M2P2), UMR7340 CNRS, Aix-Marseille Université, Centrale Marseille, 13451 Marseille Cedex (France)

    2017-06-15

    Highlights: • Complex geometry inside a PWR fuel assembly is simulated using simplified 3D models. • Structured meshes are generated as far as possible. • Fluctuating hydrodynamic and wall pressure field are analyzed using LES. • Comparative studies between square spacer grid, circular spacer grid and mixing vanes are presented. • Simulations are compared with experimental data. - Abstract: Flow-induced vibrations in a pressurized water reactor (PWR) core can cause fretting wear in fuel rods. These vibrations can compromise safety of a nuclear reactor. So, it is necessary to know the random fluctuating forces acting on the rods which cause these vibrations. In this paper, simplified 3D models like square spacer grid, circular spacer grid and symmetric mixing vanes have been used inside an annular pipe. Hydrodynamic and wall pressure characteristics are evaluated using large eddy simulations (LES). Structured meshes are generated as far as possible. Simulations are compared with an experiment. Results show that the grid and vanes have a combined effect: grid accelerates the flow whereas the vanes contribute to the swirl structures. Spectral analysis of the simulations illustrate vortex shedding phenomenon in the wake of spacer grids. This initial study opens up interesting perspectives towards improving the modeling strategy and understanding the complex phenomenon inside a PWR core.

  10. Comparative study of the contribution of various PWR spacer grid components to hydrodynamic and wall pressure characteristics

    International Nuclear Information System (INIS)

    Bhattacharjee, Saptarshi; Ricciardi, Guillaume; Viazzo, Stéphane

    2017-01-01

    Highlights: • Complex geometry inside a PWR fuel assembly is simulated using simplified 3D models. • Structured meshes are generated as far as possible. • Fluctuating hydrodynamic and wall pressure field are analyzed using LES. • Comparative studies between square spacer grid, circular spacer grid and mixing vanes are presented. • Simulations are compared with experimental data. - Abstract: Flow-induced vibrations in a pressurized water reactor (PWR) core can cause fretting wear in fuel rods. These vibrations can compromise safety of a nuclear reactor. So, it is necessary to know the random fluctuating forces acting on the rods which cause these vibrations. In this paper, simplified 3D models like square spacer grid, circular spacer grid and symmetric mixing vanes have been used inside an annular pipe. Hydrodynamic and wall pressure characteristics are evaluated using large eddy simulations (LES). Structured meshes are generated as far as possible. Simulations are compared with an experiment. Results show that the grid and vanes have a combined effect: grid accelerates the flow whereas the vanes contribute to the swirl structures. Spectral analysis of the simulations illustrate vortex shedding phenomenon in the wake of spacer grids. This initial study opens up interesting perspectives towards improving the modeling strategy and understanding the complex phenomenon inside a PWR core.

  11. Custom-made hinged spacers in revision knee surgery for patients with infection, bone loss and instability.

    Science.gov (United States)

    Macmull, S; Bartlett, W; Miles, J; Blunn, G W; Pollock, R C; Carrington, R W J; Skinner, J A; Cannon, S R; Briggs, T W R

    2010-12-01

    Polymethyl methacrylate spacers are commonly used during staged revision knee arthroplasty for infection. In cases with extensive bone loss and ligament instability, such spacers may not preserve limb length, joint stability and motion. We report a retrospective case series of 19 consecutive patients using a custom-made cobalt chrome hinged spacer with antibiotic-loaded cement. The "SMILES spacer" was used at first-stage revision knee arthroplasty for chronic infection associated with a significant bone loss due to failed revision total knee replacement in 11 patients (58%), tumour endoprosthesis in four patients (21%), primary knee replacement in two patients (11%) and infected metalwork following fracture or osteotomy in a further two patients (11%). Mean follow-up was 38 months (range 24-70). In 12 (63%) patients, infection was eradicated, three patients (16%) had persistent infection and four (21%) developed further infection after initially successful second-stage surgery. Above knee amputation for persistent infection was performed in two patients. In this particularly difficult to treat population, the SMILES spacer two-stage technique has demonstrated encouraging results and presents an attractive alternative to arthrodesis or amputation. Copyright © 2009 Elsevier B.V. All rights reserved.

  12. CFD analysis on mixing effects of spacer grids with different dimples and sizes for advanced fuel assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Yang, B.W.; Zhang, H.; Han, B.; Zha, Y.D.; Shan, J.Q. [Xi' an Jiaotong Univ. (China). School of Nuclear Science and Technology

    2016-07-15

    The thermal hydraulic characteristics of a mixing vane grid are largely dependent on the structure of key components, such as strip, spring, dimple, weld nugget, as well as the mixing vane configuration. In this paper, several types of spacer grids with different dimple shapes are modeled under subcooled boiling conditions. Prior to the application of CFD on the dimple shape analysis, the mixing effects of spacer grids were studied. After the dimple shape analysis, the side channel effect is discussed by comparing the simulation results of a 3 x 3 and a 5 x 5 spacer grid. The two phase flow CFD models in this study are validated through simple geometry showing that the calculated void fraction is in good agreement with the experimental data. The dimple comparison result shows that varying dimple structures can result in different temperatures, lateral velocities and void fraction distributions downstream of the spacer grids. Comparison of two sizes of spacer grids demonstrate that the side channel generates different flow distribution pattern in the center channel.

  13. Floating seal system for rotary devices

    Science.gov (United States)

    Banasiuk, H.A.

    1983-08-23

    This invention relates to a floating seal system for rotary devices to reduce gas leakage around the rotary device in a duct and across the face of the rotary device to an adjacent duct. The peripheral seal bodies are made of resilient material having a generally U-shaped cross section wherein one of the legs is secured to a support member and the other of the legs forms a contacting seal against the rotary device. The legs of the peripheral seal form an extended angle of intersection of about 10[degree] to about 30[degree] in the unloaded condition to provide even sealing forces around the periphery of the rotary device. The peripheral seal extends around the periphery of the support member except where intersected by radial seals which reduce gas leakage across the face of the rotary device and between adjacent duct portions. The radial seal assembly is fabricated from channel bars, the smaller channel bar being secured to the divider of the support member and a larger inverted rigid floating channel bar having its legs freely movable over the legs of the smaller channel bar forming therewith a tubular channel. A resilient flexible tube is positioned within the tubular channel for substantially its full length to reduce gas leakage across the tubular channel. A spacer extends beyond the face of the floating channel near each end of the floating channel a distance to provide desired clearance between the floating channel and the face of the rotary device. 5 figs.

  14. INTERSPINOUS SPACER IN PERSISTENT DISCOGENIC PAIN: PERCUTANEOUS APPROACH OR OPEN TECHNIQUE

    Directory of Open Access Journals (Sweden)

    José Antonio Cruz Ricardez

    Full Text Available ABSTRACT Objective: To compare the postoperative clinical course of placement of interspinous spacer with open technique (ISO with percutaneous interspinous spacer (PIS. Methods: Quasi-experimental, longitudinal study of 42 patients with discogenic pain uncontrolled with analgesics, aged 35-55 years old, 21 women, and 21 men. Clinical history, location of pain, VAS scale before and after surgery, Oswestry Disability Index and Macnab modified scale at 6 months were used. Results: When performing quantitative analysis statistical significance (p = 0.0478, 0.0466, 0.0399 was demonstrated with Student's t test between the results according to VAS scale; in the qualitative analysis with the Oswestry index and Macnab modified scale it was demonstrated the hypothesis that the results is dependent of the surgical technique. Conclusions: According to the results, we can conclude that there is a statistically significant difference depending on the surgical technique used with respect to the rate of disability and functionality in daily life as well as in the improvement of pain symptoms.

  15. Vibration characteristics of a PWR fuel rod supported by optimized H type spacer grids

    International Nuclear Information System (INIS)

    Choi, M. H.; Kang, H. S.; Yoon, K. H.; Kim, H. K.; Song, K. N.

    2002-01-01

    The spacer grids are one of the main structural components in the fuel assembly, which supports and protects the fuel rods from the external loads by seismic and coolant flow. In this study, a modal test and a FE vibration analysis using ABAQUS are performed on a PWR dummy fuel rod of 3.847 m which is continuously supported by eight Optimized H type spacer grids. The experimental results agree with previous works that the natural frequencies decrease, while the amplitudes increase, with the increase of the excitation force. The force levels showing the maximum displacement of 0.2 mm are in the range from 0.2 N to 0.3 N, and at the same force range the fundamental frequencies are measured around 42.0 Hz, at which the relatively big displacements are observed at the 7th span. The results from the modal tests and the FE analyses are compared by both Modal Assurance Criteria (MAC) values and mode shapes. The MAC values at 2nd, 4th, and 7th mode are below 50%. It is believed that the reason of the low MACs at those modes is that the vibration amplitudes of the modes are more distorted by the excitation force than those of the other modes

  16. Metagenomic data of fungal internal transcribed spacer from serofluid dish, a traditional Chinese fermented food

    Directory of Open Access Journals (Sweden)

    Peng Chen

    2016-03-01

    Full Text Available Serofluid dish (or Jiangshui, in Chinese, a traditional food in the Chinese culture for thousands of years, is made from vegetables by fermentation. In this work, microorganism community of the fermented serofluid dish was investigated by the culture-independent method. The metagenomic data in this article contains the sequences of fungal internal transcribed spacer (ITS regions of rRNA genes from 12 different serofluid dish samples. The metagenome comprised of 50,865 average raw reads with an average of 8,958,220 bp and G + C content is 45.62%. This is the first report on metagenomic data of fungal ITS from serofluid dish employing Illumina platform to profile the fungal communities of this little known fermented food from Gansu Province, China. The Metagenomic data of fungal internal transcribed spacer can be accessed at NCBI, SRA database accession no. SRP067411. Keywords: Serofluid dish, Jiangshui, Fungal ITS, Cultivation-independent, Microbial diversity

  17. Intra-Genomic Internal Transcribed Spacer Region Sequence Heterogeneity and Molecular Diagnosis in Clinical Microbiology.

    Science.gov (United States)

    Zhao, Ying; Tsang, Chi-Ching; Xiao, Meng; Cheng, Jingwei; Xu, Yingchun; Lau, Susanna K P; Woo, Patrick C Y

    2015-10-22

    Internal transcribed spacer region (ITS) sequencing is the most extensively used technology for accurate molecular identification of fungal pathogens in clinical microbiology laboratories. Intra-genomic ITS sequence heterogeneity, which makes fungal identification based on direct sequencing of PCR products difficult, has rarely been reported in pathogenic fungi. During the process of performing ITS sequencing on 71 yeast strains isolated from various clinical specimens, direct sequencing of the PCR products showed ambiguous sequences in six of them. After cloning the PCR products into plasmids for sequencing, interpretable sequencing electropherograms could be obtained. For each of the six isolates, 10-49 clones were selected for sequencing and two to seven intra-genomic ITS copies were detected. The identities of these six isolates were confirmed to be Candida glabrata (n=2), Pichia (Candida) norvegensis (n=2), Candida tropicalis (n=1) and Saccharomyces cerevisiae (n=1). Multiple sequence alignment revealed that one to four intra-genomic ITS polymorphic sites were present in the six isolates, and all these polymorphic sites were located in the ITS1 and/or ITS2 regions. We report and describe the first evidence of intra-genomic ITS sequence heterogeneity in four different pathogenic yeasts, which occurred exclusively in the ITS1 and ITS2 spacer regions for the six isolates in this study.

  18. Thermal Performance Testing of Cryogenic Multilayer Insulation with Silk Net Spacers

    International Nuclear Information System (INIS)

    Johnson, W L; Frank, D J; Nast, T C; Fesmire, J E

    2015-01-01

    Early comprehensive testing of cryogenic multilayer insulation focused on the use of silk netting as a spacer material. Silk netting was used for multiple test campaigns that were designed to provide baseline thermal performance estimates for cryogenic insulation systems. As more focus was put on larger systems, the cost of silk netting became a deterrent and most aerospace insulation firms were using Dacron (or polyester) netting spacers by the early 1970s. In the midst of the switch away from silk netting there was no attempt to understand the difference between silk and polyester netting, though it was widely believed that the silk netting provided slightly better performance. Without any better reference for thermal performance data, the silk netting performance correlations continued to be used. In order to attempt to quantify the difference between the silk netting and polyester netting, a brief test program was developed. The silk netting material was obtained from Lockheed Martin and was tested on the Cryostat-100 instrument in three different configurations, 20 layers with both single and double netting and 10 layers with single netting only. The data show agreement within 15 - 30% with the historical silk netting based correlations and show a substantial performance improvement when compared to previous testing performed using polyester netting and aluminum foil/fiberglass paper multilayer insulation. Additionally, the data further reinforce a recently observed trend that the heat flux is not directly proportional to the number of layers installed on a system. (paper)

  19. Process development for the manufacturing of state-of-the-art spacer grids

    Energy Technology Data Exchange (ETDEWEB)

    Schebitz, Florian; Dietrich, Matthias [Advanced Nuclear Fuels GmbH, Karlstein (Germany)

    2013-07-01

    At the beginning it was questioned if 'time to market' is really important for the nuclear industry. The clear answer is YES. Even if the development times might be longer compared to projects in other industries it is still beneficial to use concurrent engineering. In the world wide network of manufacturing sites, Advanced Nuclear Fuels GmbH in Karlstein is quite often involved when the development of new processes is necessary. As ANF Karlstein is delivering products around the world the experience with different customer requirements supports an optimized solution in order to fulfill these principle requirements and to deliver state-of-the-art products like spacer grids. Continues feedback from process development already improves the first prototypes. In the meantime ANF Karlstein manufactured the components for both new fuel assembly designs which are introduced as a first set of Lead Fuel Assemblies. For the manufacturing of the next sets of spacer grids (for tests and next series of Lead Fuel Assemblies) the described processes will be used and further improved, so that an industrialized solution is available. (orig.)

  20. Two-stage revision of septic knee prosthesis with articulating knee spacers yields better infection eradication rate than one-stage or two-stage revision with static spacers.

    Science.gov (United States)

    Romanò, C L; Gala, L; Logoluso, N; Romanò, D; Drago, L

    2012-12-01

    The best method for treating chronic periprosthetic knee infection remains controversial. Randomized, comparative studies on treatment modalities are lacking. This systematic review of the literature compares the infection eradication rate after two-stage versus one-stage revision and static versus articulating spacers in two-stage procedures. We reviewed full-text papers and those with an abstract in English published from 1966 through 2011 that reported the success rate of infection eradication after one-stage or two-stage revision with two different types of spacers. In all, 6 original articles reporting the results after one-stage knee exchange arthoplasty (n = 204) and 38 papers reporting on two-stage revision (n = 1,421) were reviewed. The average success rate in the eradication of infection was 89.8% after a two-stage revision and 81.9% after a one-stage procedure at a mean follow-up of 44.7 and 40.7 months, respectively. The average infection eradication rate after a two-stage procedure was slightly, although significantly, higher when an articulating spacer rather than a static spacer was used (91.2 versus 87%). The methodological limitations of this study and the heterogeneous material in the studies reviewed notwithstanding, this systematic review shows that, on average, a two-stage procedure is associated with a higher rate of eradication of infection than one-stage revision for septic knee prosthesis and that articulating spacers are associated with a lower recurrence of infection than static spacers at a comparable mean duration of follow-up. IV.

  1. Flow resistance of orifices and spacers of BWR thermal-hydraulic and neutronic coupling loop

    International Nuclear Information System (INIS)

    Iguchi, Tadashi; Asaka, Hideaki; Nakamura, Hideo

    2002-03-01

    Authors are performing THYNC experiments to study thermal-hydraulic instability under neutronic and thermal-hydraulic coupling. In THYNC experiments, the orifices are installed at the exit of the test section and the spacers are installed in the test section, in order to properly simulate in-core thermal-hydraulics in the reactor core. It is necessary to know the flow resistance of the orifices and spacers for the analysis of THYNC experimental results. Consequently, authors measured the flow resistance of orifice and spacer under single-phase and two-phase flows. Using the experimental results, authors investigated the dependency of the flow resistances on the parameters, such as pressure, mass flux, an geometries. Furthermore, authors investigated the applicability of the basic two-phase flow models, for example the separate flow model, to the two-phase flow multiplier. As the result of the investigation on the single-phase flow experiment, it was found (1) that the effects of pressure and mass flux flow resistance are described by a function of Reynolds number, and (2) that flow resistances of the orifice and the spacer are calculated with the previous prediction methods. However, it was necessary to introduce an empirical coefficient, since it was difficult to predict accurately the flow resistance only with the previous prediction method due to the complicated geometry dependency, for example a flow area blockage ratio. On the other hand, according to the investigation on two-phase flow experiment, the followings were found. (1) Relation between the two-phase flow multiplier and the quality is regarded to be linear under pressure of 2MPa - 7MPa. The relation is dependent on pressure and geometry, and is little dependent on mass flux. (2) Relation between the two-phase flow multiplier and void fraction is little dependent on pressure, mass flux, and geometry under pressure of 0.2MPa - 7MPa and void fraction less than 0.6. The relation is less dependent on

  2. Octopus: LLL's computing utility

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The Laboratory's Octopus network constitutes one of the greatest concentrations of computing power in the world. This power derives from the network's organization as well as from the size and capability of its computers, storage media, input/output devices, and communication channels. Being in a network enables these facilities to work together to form a unified computing utility that is accessible on demand directly from the users' offices. This computing utility has made a major contribution to the pace of research and development at the Laboratory; an adequate rate of progress in research could not be achieved without it. 4 figures

  3. Mutations in Cas9 Enhance the Rate of Acquisition of Viral Spacer Sequences during the CRISPR-Cas Immune Response.

    Science.gov (United States)

    Heler, Robert; Wright, Addison V; Vucelja, Marija; Bikard, David; Doudna, Jennifer A; Marraffini, Luciano A

    2017-01-05

    CRISPR loci and their associated (Cas) proteins encode a prokaryotic immune system that protects against viruses and plasmids. Upon infection, a low fraction of cells acquire short DNA sequences from the invader. These sequences (spacers) are integrated in between the repeats of the CRISPR locus and immunize the host against the matching invader. Spacers specify the targets of the CRISPR immune response through transcription into short RNA guides that direct Cas nucleases to the invading DNA molecules. Here we performed random mutagenesis of the RNA-guided Cas9 nuclease to look for variants that provide enhanced immunity against viral infection. We identified a mutation, I473F, that increases the rate of spacer acquisition by more than two orders of magnitude. Our results highlight the role of Cas9 during CRISPR immunization and provide a useful tool to study this rare process and develop it as a biotechnological application. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Steady-state, local temperature fields with turbulent liquid sodium flow in nominal and disturbed bundle geometries with spacer grids

    International Nuclear Information System (INIS)

    Moeller, R.; Tschoeke, H.

    1980-01-01

    The operating reliability of nuclear reactors calls for a reliable strength analysis of the highly loaded core elements, one of its prerequisites being the reliable determination of the three-dimensional velocity and temperature fields. To verify thermohydraulics computer programs, extensive local temperature measurements in the rod claddings of the critical bundle zone were performed on a heated 19-rod bundle model with sodium flow and provided with spacer grids (P/D = 1.30; W/D = 1.19). The essential results are: - Outside the spacer grids, the azimuthal temperature variations of the side and corner rods are approximately 10-fold those of rods in the central bundle zone. - The spacer grids investigated give rise to great local temperature peaks and correspondingly great temperature gradients in the axial and azimuthal directions immediately around the support points. - Continuous reduction of a subchannel by rod bowing results in substantial rises of temperature which, however, are limited to adjacent cladding tubes. (orig.)

  5. Vibrational modes and strain in GaN/AlN quantum dot stacks: dependence on spacer thickness

    Energy Technology Data Exchange (ETDEWEB)

    Fresneda, J.; Cros, A.; Llorens, J.M.; Garcia-Cristobal, A.; Cantarero, A. [Institut de Ciencia del Materials, Universitat de Valencia, 46071 Valencia (Spain); Amstatt, B.; Bellet-Amalric, E.; Daudin, B. [CEA-CNRS Group, Nanophysique et Semiconducteurs, DRFMC/SP2M/PSC, CEA-Grenoble, 17 rue des Martyrs, 38054 Grenoble cedex 9 (France)

    2007-06-15

    We have investigated the influence of spacer thickness on the vibrational and strain characteristics of GaN/AlN quantum dot multilayers (QD). The Raman shift corresponding to the E{sub 2h} vibrational mode related to the QDs has been analyzed for AlN thicknesses ranging from 4.4 nm to 13 nm, while the amount of GaN deposited in each layer remained constant from sample to sample. It is shown that there is a rapid blue shift of the GaN vibrational mode with spacer thickness when its value is smaller than 7 nm while it remains almost constant for thicker spacers. A rapid increase of the Raman line-width in the thicker samples is also observed. The experimental behavior is discussed in comparison with the results of a theoretical model for the strain in the QDs. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  6. Development of a laser multi-layer cladding technology for damage mitigation of fuel spacers in Hanaro reactor

    International Nuclear Information System (INIS)

    Kim, J. S.; Lee, D. H.; Hwang, S. S.; Suh, J. H.

    2002-01-01

    A laser multi-layer cladding technology was developed to mitigate the fretting wear damages occurred at fuel spacers in Hanaro reactor. The detailed experimental results are as follows. 1) Analyses of fretting wear damages and fabrication process of fuel spacers 2) Development and analysis of spherical Al 6061 T-6 alloy powders for the laser cladding 3) Analysis of parameter effects on laser cladding process for clad bids, and optimization of laser cladding process 4) Analysis on the changes of cladding layers due to overlapping factor change 5) Microstructural observation and phase analysis 6) Characterization of materials properties (hardness and wear tests) 7) Manufacture of prototype fuel spacers 8) Development of a vision system and revision of its related softwares

  7. Multi-Scaled Modeling the Mechanical Properties of Tubular Composites Reinforced with Innovated 3D Weft Knitted Spacer Fabrics

    Science.gov (United States)

    Omrani, Elahe; Hasani, Hossein; Dibajian, Sayed Houssain

    2018-02-01

    Textile composites of 3D integrated spacer configurations have been recently focused by several researchers all over the world. In the present study, newly-designed tubular composites reinforced with 3D spacer weft knitted fabrics were considered and the effects of their structural parameters on some applicable mechanical properties were investigated. For this purpose, two different samples of 3D spacer weft knitted textile types in tubular form were produced on an electronic flat knitting machine, using glass/nylon hybrid yarns. Thermoset tubular-shaped composite parts were manufactured via vacuum infusion molding process using epoxy resin. The mechanical properties of the produced knitted composites in term of external static and internal hydrostatic pressures were evaluated. Resistance of the produced composites against the external static and internal hydrostatic pressures was numerically simulated using multi-scale modeling method. The finding revealed that there is acceptable correlation between experimental and theoretical results.

  8. Spacer stability and prostate position variability during radiotherapy for prostate cancer applying a hydrogel to protect the rectal wall

    International Nuclear Information System (INIS)

    Pinkawa, Michael; Piroth, Marc D.; Holy, Richard; Escobar-Corral, Nuria; Caffaro, Mariana; Djukic, Victoria; Klotz, Jens; Eble, Michael J.

    2013-01-01

    Background and purpose: The aim was to evaluate the spacer dimensions and prostate position variability during the course of radiotherapy for prostate cancer. Materials and methods: CT scans were performed in a group of 15 patients (G1) after the 10 ml injection of a hydrogel spacer (SpaceOAR™) and 30 patients without a spacer (G2) before the beginning of treatment (CT1) and in the last treatment week, 10–12 weeks following spacer implantation (CT2). Spacer dimensions and displacements were determined and prostate displacements compared. Results: Mean volume of the hydrogel increased slightly (17%; p 2 cm 3 . The average displacement of the hydrogel center of mass was 0.6 mm (87% ⩽ 2.2 mm), −0.6 mm (100% ⩽ 2.2 mm) and 1.4 mm (87% ⩽ 4.3 mm) in the x-, y- and z-axes (not significant). The average distance between prostate and anterior rectal wall before/at the end of radiotherapy was 1.6 cm/1.5 cm, 1.2 cm/1.3 cm and 1.0 cm/1.1 cm at the level of the base, middle and apex (G1). Prostate position variations were similar comparing G1 and G2, but significant systematic posterior displacements were only found in G2. Conclusions: A stable distance between the prostate and anterior rectal wall results during the radiotherapy course after injection of the spacer before treatment planning. Larger posterior prostate displacements could be reduced

  9. Bronchodilator Effect of Tiotropium via Respimat®Administered with a Spacer in Patients with Chronic Obstructive Pulmonary Disease (COPD).

    Science.gov (United States)

    Ogasawara, Takashi; Sakata, Jun; Aoshima, Yoichiro; Tanaka, Kazuki; Yano, Toshiaki; Kasamatsu, Norio

    2017-09-15

    Objective Among elderly patients with chronic obstructive pulmonary disease (COPD), there are some patients who cannot inhale tiotropium via Respimat ® due to poor hand-lung coordination. This study aimed to examine whether or not tiotropium inhalation therapy using Respimat ® with a spacer increased the forced expiratory volume in 1 s (FEV 1 ) in patients with COPD. Methods A randomized, crossover, single-center study was conducted in 18 patients with stable COPD. Tiotropium (5 μg) via Respimat ® with or without a spacer (AeroChamber ® ) was administered for 2 weeks. Following a 2-week washout period using a transdermal tulobuterol patch (2 mg per day), participants were then crossed over to the other inhalation therapy with respect to spacer use. The trough FEV 1 was measured at every visit using a spirometer. A questionnaire regarding inhalation therapy was administered to patients at the final visit. Results The administration of tiotropium via Respimat ® both with and without a spacer significantly increased the trough FEV 1 from baseline during each treatment period, with mean differences of 115.0±169.6 mL and 92.8±128.1 mL, respectively. There was no significant difference in the change in the trough FEV 1 between the 2 procedures (p=0.66). A total of 86% of patients reported that inhalation using a spacer was not difficult, and more than half also rated both the usage and maintenance of the AeroChamber ® as easy. Conclusion Tiotropium inhalation therapy administered via Respimat ® using a spacer exerted a bronchodilatory effect similar to that observed with tiotropium Respimat ® alone.

  10. Patella tendon injuries secondary to cement spacers used at first-stage revision of infected total knee replacement

    Directory of Open Access Journals (Sweden)

    Wasim S Khan

    2015-04-01

    Full Text Available We describe a series of three patients who sustained patella tendon injuries in infected TKAs following the use of a static cement spacer at first-stage knee revision. The patella tendon injuries resulted in significant compromise to wound healing and knee stability requiring multiple surgeries. The mid-term function was poor with an Oxford score at 24 months ranging from 12-20. Based on our experience, we advise caution in the use of static cement spacer blocks. If they are to be used, we recommend that they should be keyed in the bone to prevent patella tendon injuries.

  11. Porosity of spacer-filled channels in spiral-wound membrane systems: Quantification methods and impact on hydraulic characterization

    KAUST Repository

    Siddiqui, Amber

    2017-04-13

    The porosity of spacer-filled feed channels influences the hydrodynamics of spiral-wound membrane systems and impacts the overall performance of the system. Therefore, an exact measurement and a detailed understanding of the impact of the feed channel porosity is required to understand and improve the hydrodynamics of spiral-wound membrane systems applied for desalination and wastewater reuse. The objectives of this study were to assess the accuracy of porosity measurement techniques for feed spacers differing in geometry and thickness and the consequences of using an inaccurate method on hydrodynamic predictions, which may affect permeate production. Six techniques were applied to measure the porosity namely, three volumetric calculations based on spacer strand count together with cuboidal (SC), cylindrical (VCC) and ellipsoidal volume calculation (VCE) and three independent techniques based on volume displacement (VD), weight and density (WD) and computed tomography scanning (CT). The CT method was introduced as an alternative for the other five already existing and applied methods in practice.Six feed spacers used for the porosity measurement differed in filament thickness, angle between the filaments and mesh-size. The results of the studies showed differences between the porosities, measured by the six methods. The results of the microscopic techniques SC, VCC and VCE deviated significantly from measurements by VD, WD and CT, which showed similar porosity values for all spacer types.Depending on the maximum deviation of the porosity measurement techniques from –6% to +6%, (i) the linear velocity deviations were −5.6% and +6.4% respectively and (ii) the pressure drop deviations were –31% and +43% respectively, illustrating the importance of an accurate porosity measurement. Because of the accuracy and standard deviation, the VD and WD method should be applied for the porosity determination of spacer-filled channels, while the CT method is recommended for

  12. Experimental studies of the effect of functional spacers to annular flow in subchannels of a BWR fuel element

    Energy Technology Data Exchange (ETDEWEB)

    Damsohn, M., E-mail: damsohn@lke.mavt.ethz.c [ETH Zurich, Department of Mechanical and Process Engineering, Sonneggstrasse 3, 8092 Zuerich (Switzerland); Prasser, H.-M. [ETH Zurich, Department of Mechanical and Process Engineering, Sonneggstrasse 3, 8092 Zuerich (Switzerland)

    2010-10-15

    For the prediction of dryout in fuel elements of boiling water reactors, the dynamic behavior of the water film covering the fuel rod has to be understood. This paper provides high resolved experimental data of the liquid film and gives insight into the dynamic film behavior. The experiments of this work were conducted in a vertical channel representing a pair of neighboring subchannels of a BWR fuel rod bundle. Air and water at ambient pressure and temperature are used as model fluids, creating an annular flow in the test section. The influence of different functional spacer shapes on the liquid film has been studied. The heart of the instrumentation is a liquid film sensor (LFS), which measures the film thickness distribution around a half cylinder with a matrix of 64 x 16 measuring points with a time resolution of 10,000 frames per second and a spatial resolution of 2 mm x 2 mm. The high resolution allows for a visualization of the dynamic liquid film as a movie animation. Principals of the dynamic behavior of the liquid film are observed. The time-averaged film thickness distributions show that the spacers structure the liquid film significantly. The gaseous phase is accelerated due to the cross-section blockage caused by the spacer. This leads to a local thinning of the liquid film downstream of the spacer. Two statistical evaluation methods are presented to determine different dynamic wave properties: The wave velocity as function of the wave height, the traveling path of the waves and the location of wave separation and merge events. The first evaluation method shows that big waves move generally faster than small waves. The analysis further shows wave acceleration in close proximity of the spacer with subsequent deceleration further downstream. Analyzing the wave as a two-dimensional entity it can be seen that the wave paths are clearly structured by the spacer and hence do not travel circumferentially around the fuel rod. Wave separation and merge has a

  13. Experimental studies of the effect of functional spacers to annular flow in subchannels of a BWR fuel element

    International Nuclear Information System (INIS)

    Damsohn, M.; Prasser, H.-M.

    2010-01-01

    For the prediction of dryout in fuel elements of boiling water reactors, the dynamic behavior of the water film covering the fuel rod has to be understood. This paper provides high resolved experimental data of the liquid film and gives insight into the dynamic film behavior. The experiments of this work were conducted in a vertical channel representing a pair of neighboring subchannels of a BWR fuel rod bundle. Air and water at ambient pressure and temperature are used as model fluids, creating an annular flow in the test section. The influence of different functional spacer shapes on the liquid film has been studied. The heart of the instrumentation is a liquid film sensor (LFS), which measures the film thickness distribution around a half cylinder with a matrix of 64 x 16 measuring points with a time resolution of 10,000 frames per second and a spatial resolution of 2 mm x 2 mm. The high resolution allows for a visualization of the dynamic liquid film as a movie animation. Principals of the dynamic behavior of the liquid film are observed. The time-averaged film thickness distributions show that the spacers structure the liquid film significantly. The gaseous phase is accelerated due to the cross-section blockage caused by the spacer. This leads to a local thinning of the liquid film downstream of the spacer. Two statistical evaluation methods are presented to determine different dynamic wave properties: The wave velocity as function of the wave height, the traveling path of the waves and the location of wave separation and merge events. The first evaluation method shows that big waves move generally faster than small waves. The analysis further shows wave acceleration in close proximity of the spacer with subsequent deceleration further downstream. Analyzing the wave as a two-dimensional entity it can be seen that the wave paths are clearly structured by the spacer and hence do not travel circumferentially around the fuel rod. Wave separation and merge has a

  14. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  15. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  16. Role of methylene spacer in the excitation energy transfer in europium 1- and 2- naphthylcarboxylates

    Energy Technology Data Exchange (ETDEWEB)

    Zhuravlev, K. [V.A. Kotelnikov Institute of Radioengineering and Electronics of RAS, 1 Vvedenskii sq., Fryazino Moscow reg. 141190 (Russian Federation); Tsaryuk, V., E-mail: vit225@ire216.msk.s [V.A. Kotelnikov Institute of Radioengineering and Electronics of RAS, 1 Vvedenskii sq., Fryazino Moscow reg. 141190 (Russian Federation); Kudryashova, V.; Pekareva, I. [V.A. Kotelnikov Institute of Radioengineering and Electronics of RAS, 1 Vvedenskii sq., Fryazino Moscow reg. 141190 (Russian Federation); Sokolnicki, J. [Faculty of Chemistry, University of WrocLaw, 14 F. Joliot-Curie str., WrocLaw 50-383 (Poland); Yakovlev, Yu. [V.A. Kotelnikov Institute of Radioengineering and Electronics of RAS, 1 Vvedenskii sq., Fryazino Moscow reg. 141190 (Russian Federation)

    2010-08-15

    A series of compounds Ln(RCOO){sub 3}.Phen (Ln=Eu, Gd, Tb; RCOO{sup -}-1- and 2-naphthoate, 1- and 2-naphthylacetate, 1- and 2-naphthoxyacetate anions, Phen-1,10-phenanthroline) was investigated by methods of optical spectroscopy. Compounds of composition Ln(RCOO){sub 3}.nH{sub 2}O with the same carboxylate ligands are also considered. Results of studies of the effects of methylene spacer decoupling the {pi}-{pi}- or p-{pi}-conjugation in the naphthylcarboxylate ligand on the structure of Eu{sup 3+} coordination centre, on the lifetime of {sup 5}D{sub 0} (Eu{sup 3+}) state, and on processes of the excitation energy transfer to Eu{sup 3+} or Tb{sup 3+} ions are presented. Introduction of the methylene bridge in the ligand weakens the influence of the steric hindrances in forming of a crystal lattice and results in lowering the distortion of the Eu{sup 3+} luminescence centre, and in elongation of the observed {sup 5}D{sub 0} lifetime {tau}{sub obs}. The latter is caused by decrease in contribution of the radiative processes rate 1/{tau}{sub r}. This is confirmed by the correlation between the lifetimes {tau}{sub obs} and the quantities '{tau}{sub r}.const' inversely proportional to the total integral intensities of Eu(RCOO){sub 3}.Phen luminescence spectra. The methylene spacer performs a role of regulator of sensitization of the Ln{sup 3+} luminescence efficiency by means of an influence on mutual location of lowest triplet states of the ligands, the ligand-metal charge transfer (LMCT) states, and the emitting states of Ln{sup 3+} ions. The lowest triplet state in lanthanide naphthylcarboxylate adducts with Phen is related to carboxylate anion. A presence of the methylene spacer in naphthylcarboxylate ligand increases the triplet state energy. At the same time, the energy of 'carboxylic group-Eu{sup 3+} ion' charge transfer states falls, which can promote the degradation of excitation energy. In naphthylcarboxylates investigated a range of the

  17. Effects of spacers on blockage of coolant channels in clad melting accidents

    Energy Technology Data Exchange (ETDEWEB)

    Eggen, D. T.; Scale, T.; Hsieh, S. [Northwestern Univ., Evanston, IL (United States). The Technological Inst.

    1977-07-01

    The elements and configuration of these assemblies are representative of the current design for a GCFR. The fuel elements are stainless-steel clad, mixed-oxide spaced by a grid structure on 250 mm centers with a pitch of 9.5 mm, diameter, 7.2 mm, and cladding thickness, 0.5 m. Three series of experiments have been conducted to study the flow and disposition of molten cladding metal into a lower powered blanket region of the reactor following a loss of flow situation. The first two series used a simulant fuel-element bundle to simplify the experimental procedure and make visual observation possible. The 'fuel' was simulated by mullite rods 6.4 mm in diameter and 610 mm long. These were clad with a 50 Pb/50 Sn alloy tubing which was drawn onto the 'fuel'. The first series used cast spacers with webs of about 0.5-0.55 mm thickness placed 175 and 425 mm from the top end of the assembly. The second series used grid spacers fabricated of 0.25 mm alloy strips. This provided a more accurate representation of the hydraulic diameter. The bundle was encased in a hexagonal glass tube. The bundle was at 22/sup 0/C and the molten alloy was poured at a temperature of 260/sup 0/C (35/sup 0/C superheat). Motion pictures recorded the experiments and the bundle was sectioned for observation. The third set of experiments was done with a stainless steel bundle of 37 elements fabricated of mullite rods, 7.14 mm diameter. The stainless steel cladding had an O.D. of 8.41 mm. The element pitch was 11.1 mm. The grid spacers were prototypic. The experiment was conducted in an inert-gas tube furnace. The 'core fuel' cladding was melted in an induction furnace and the molten liquid flowed through the center seven element channels. X-ray pictures were taken after the tests and the bundle was sectioned for further study.

  18. Advanced 65 nm CMOS devices fabricated using ultra-low energy plasma doping

    International Nuclear Information System (INIS)

    Walther, S.; Lenoble, D.; Lallement, F.; Grouillet, A.; Erokhin, Y.; Singh, V.; Testoni, A.

    2005-01-01

    For leading edge CMOS and DRAM technologies, plasma doping (PLAD) offers several unique advantages over conventional beamline implantation. For ultra-low energy source and drain extensions (SDE), source drain contact and high dose poly doping implants PLAD delivers 2-5x higher throughput compared to beamline implanters. In this work we demonstrate process performance and process integration benefits enabled by plasma doping for advanced 65 nm CMOS devices. Specifically, p + /n ultra-shallow junctions formed with BF 3 plasma doping have superior X j /R s characteristics to beamline implants and yield up to 30% lower R s for 20 nm X j while using standard spike anneal with ramp-up rate of 75 deg. C/s. These results indicate that PLAD could extend applicability of standard spike anneal by at least one technology node past 65 nm. A CMOS split lot has been run to investigate process integration advantages unique to plasma doping and to determine CMOS device characteristics. Device data measured on 65 nm transistors fabricated with offset spacers indicate that devices with SDE formed by plasma doping have superior V t roll-off characteristics arguably due to improved lateral gate-overlap of PLAD SDE junctions. Furthermore, offset spacers could be eliminated in 65 nm devices with PLAD SDE implants while still achieving V t roll-off and I on -I off performance at least equivalent to control devices with offset spacers and SDE formed by beamline implantation. Thus, another advantage of PLAD is simplified 65 nm CMOS manufacturing process flow due to elimination of offset spacers. Finally, we present process transfer from beamline implants to PLAD for several applications, including SDE and gate poly doping with very high productivity

  19. Clinical observation on the reconstruction of large areas lower eyelid defect with Medpor spacer graft

    Directory of Open Access Journals (Sweden)

    Hai-Yan Li

    2014-08-01

    Full Text Available AIM: To observe the effects of porous polyethylene(Medporas a spacer graft in the reconstruction of large areas eyelid defect after the operation of malignant tumors of lower eyelids.METHODS: Nineteen cases(19 eyesof malignant tumors of lower eyelid underwent the eyelid reconstruction were selected. Medpor lower eyelid inserts implantation were used to replace tarsal joint sliding conjunctival flap and pedicle flap, and repaired full-thickness lower eyelid defects then underwent eyelid reconstruction. RESULTS: Appearance of eyelids and functional improvements were satisfactory with no stimulation on the eyeball and no effect on the visual function. Implants is with no absorption, shift, exclusion or infection and no tumor recurrence in all cases during the follow up for 6-36mo.CONCLUSION: Medpor lower eyelid inserts implantation can instead tarsal plate for the reconstruction of medium to large areas lower eyelid defect, which is easy performing with rare complications. It is an ideal alternatives of tarsal plate.

  20. Differences in the second internal transcribed spacer of four species of Nematodirus (Nematoda: Molineidae).

    Science.gov (United States)

    Newton, L A; Chilton, N B; Beveridge, I; Gasser, R B

    1998-02-01

    Genetic differences among Nematodirus spathiger, Nematodirus filicollis, Nematodirus helvetianus and Nematodirus battus in the nucleotide sequence of the second internal transcribed spacer (ITS-2) of ribosomal DNA ranged from 3.9 to 24.7%. Pairwise comparisons of their ITS-2 sequences indicated that the most genetically similar species were N. spathiger and N. helvetianus. N. battus was the most genetically distinct species, with differences ranging from 22.8 to 24.7% with respect to the other three species. Some of the nucleotide differences among species provided different endonuclease restriction sites that could be used in restriction fragment length polymorphism studies. The ITS-2 sequence data may prove useful in studies of the systematics of molineid nematodes.

  1. Vibration analysis of a dummy fuel rod continuously supported by spacer grids

    International Nuclear Information System (INIS)

    Choi, Myoung-Hwan; Kang, Heung-Seok; Yoon, Kyung-Ho; Song, Kee-Nam; Jung, Youn-Ho

    2003-01-01

    A modal testing and a finite element (FE) analysis using ABAQUS on a dummy fuel rod continuously supported by Optimized H type (OHT) and New Doublet (ND) spacer grids are performed to obtain the vibration characteristics such as natural frequencies and mode shapes and to verify the FE model used. The results from the test and the FE analysis are compared according to modal assurance criteria values. The natural frequency differences between the two methods as well as the mode comparison results for the rod with OHT SG are better than those with ND SG. That is, in the case of the ND grid model using beam-spring elements, there was a large discrepancy between the two methods. Thus, we tried to modify the FE model for ND SG considering the contact phenomena between the fuel rod and the SG. The results of the new model showed good agreement with the experiment compared with those of a beam-spring model

  2. Fine-tuning the CAR spacer improves T-cell potency

    Science.gov (United States)

    Watanabe, Norihiro; Bajgain, Pradip; Sukumaran, Sujita; Ansari, Salma; Heslop, Helen E.; Rooney, Cliona M.; Brenner, Malcolm K.; Leen, Ann M.; Vera, Juan F.

    2016-01-01

    ABSTRACT The adoptive transfer of genetically engineered T cells expressing chimeric antigen receptors (CARs) has emerged as a transformative cancer therapy with curative potential, precipitating a wave of preclinical and clinical studies in academic centers and the private sector. Indeed, significant effort has been devoted to improving clinical benefit by incorporating accessory genes/CAR endodomains designed to enhance cellular migration, promote in vivo expansion/persistence or enhance safety by genetic programming to enable the recognition of a tumor signature. However, our efforts centered on exploring whether CAR T-cell potency could be enhanced by modifying pre-existing CAR components. We now demonstrate how molecular refinements to the CAR spacer can impact multiple biological processes including tonic signaling, cell aging, tumor localization, and antigen recognition, culminating in superior in vivo antitumor activity. PMID:28180032

  3. Comparison of the effect of broncodiatory albotrol from spacer and nebulazor foe freatment of Astma patients

    Directory of Open Access Journals (Sweden)

    sasan tavana

    2007-04-01

    Full Text Available Tavana S1, Nadi E1, Ansari M2, zeraati F3, Hashemi H1, Mani Kashani Kh4, Mavallat M5 1. Assistant professor, Department of internal, Faculty of medicine, Hamedan University of medical sciences 2. Associate professor, Department of internal, Faculty of medicine, Hamedan University of medical sciences 3. Associate professor, Department of Pharmacology, Faculty of medicine, Hamedan University of medical sciences 4. Instructor, Department of social medicine, Faculty of medicine, Hamedan University of medical sciences 5. General practitioner, Tuberculosis and lung research group, Faculty of medicine, Hamedan University of medical sciences Abstract Background: Asthma is an inflammatory and chronic disorder of trachobronchial tree that is associated with increased response to allergens. Treatment of acute attack of asthma is short acting b 2 agonist such as Albuterol that is used via a nebulizer or Metered-dose inhaler (MDI with and attached spacer. Object of this study was evaluation of therapeutic effects of Albuterol via a nebulizer or MDI with an attached holding chamber in patients that had been referred to Emergency departement of Mobasher Hospital in Hamadan. Materials and methods: The present study was a clinical trial (before and after in 60 patients that were suffered from acute attack asthma. Inclusion criterias were 16-65 years old age patients, FEV1, below 60% of predicted value, and cooperation for spirometry performance. Exclusion criterias were COPD, cardiovascular disorders, pneumonia, preumothorex, or their systemic or pulmonary disorders,severe respiratory failure with cyanosis or confusion, pregnancy and smoking. On arrival to the ED, all patients underwent spirometery and all of patients received oxygen and a single dose of 8 mg intravenous dexamethasone. Immediately thereafter patients were randomized to two groups.The study was designed as double blind trial. The first group patients received four puffs Albuterol attached to

  4. CFD prediction of flow and phase distribution in fuel assemblies with spacers

    Energy Technology Data Exchange (ETDEWEB)

    Anglart, H.; Nylund, O. [ABB Atom AB, Vasteras (Switzerland); Kurul, N. [Rensselaer Polytechnic Institute, Troy, NY (United States)] [and others

    1995-09-01

    This paper is concerned with the modeling and computation of multi-dimensional two-phase flows in BWR fuel assemblies. The modeling principles are presented based on using a two-fluid model in which lateral interfacial effects are accounted for. This model has been used to evaluate the velocity fields of both vapor and liquid phases, as well as phase distribution, between fuel elements in geometries similar to BWR fuel bundles. Furthermore, this model has been used to predict, in a detailed mechanistic manner, the effects of spacers on flow and phase distribution between, and pressure drop along, fuel elements. The related numerical simulations have been performed using a CFD computer code, CFDS-FLOW3D.

  5. A Numerical Analysis on the Local Deformation of a Spacer Grid Structure for Nuclear Fuel Cells

    International Nuclear Information System (INIS)

    Jang, Myung-Geun; Na, Geum Ju; Kim, Jong-Bong; Shin, Hyunho

    2016-01-01

    The result of a preliminary numerical investigation on local deformation characteristics of a multi-layered spacer-grid structure with five guide tubes is reported based on implicit finite element analysis. For the numerical analysis, displacements of top and bottom cross sections of each guide tube in a single-layer model were constrained while a lateral displacement was imposed on the single layer. Unlike the impact hammer test that is generally employed to characterize the deformation characteristics of the space-grid structure, the buckling phenomenon occurs locally in this study; it takes place at the inner grids around each tube and the degree of bucking is more apparent for tubes near the lateral surface where the lateral displacement was imposed. (paper)

  6. Optimisation of automated ribosomal intergenic spacer analysis for the estimation of microbial diversity in fynbos soil

    Directory of Open Access Journals (Sweden)

    Karin Jacobs

    2010-07-01

    Full Text Available Automated ribosomal intergenic spacer analysis (ARISA has become a commonly used molecular technique for the study of microbial populations in environmental samples. The reproducibility and accuracy of ARISA, with and without the polymerase chain reaction (PCR are important aspects that influence the results and effectiveness of these techniques. We used the primer set ITS4/ITS5 for ARISA to assess the fungal community composition of two sites situated in the Sand Fynbos. The primer set proved to deliver reproducible ARISA profiles of the fungal community composition with little variation observed between ARISA-PCRs. Variation that occurred in a sample due to repeated DNA extraction is expected for ecological studies. This reproducibility made ARISA a useful tool for the assessment and comparison of diversity in ecological samples. In this paper, we also offered particular suggestions concerning the binning strategy for the analysis of ARISA profiles.

  7. Amino propynyl benzoic acid building block in rigid spacers of divalent ligands binding to the Syk SH2 domains with equally high affinity as the natural ligand

    NARCIS (Netherlands)

    Dekker, Frank J; de Mol, Nico J; Fischer, Marcel J E; Liskamp, Rob M J; Dekker, Frank

    2003-01-01

    The construction of rigid spacers composed of amino propynyl benzoic acid building blocks is described. These spacers were used to link two phosphopeptide ligand sites towards obtaining divalent ligands with a high affinity for Syk tandem SH2 domains, which are important in signal transduction. The

  8. Estimating Utility

    DEFF Research Database (Denmark)

    Arndt, Channing; Simler, Kenneth R.

    2010-01-01

    A fundamental premise of absolute poverty lines is that they represent the same level of utility through time and space. Disturbingly, a series of recent studies in middle- and low-income economies show that even carefully derived poverty lines rarely satisfy this premise. This article proposes a......, with the current approach tending to systematically overestimate (underestimate) poverty in urban (rural) zones.......A fundamental premise of absolute poverty lines is that they represent the same level of utility through time and space. Disturbingly, a series of recent studies in middle- and low-income economies show that even carefully derived poverty lines rarely satisfy this premise. This article proposes...... an information-theoretic approach to estimating cost-of-basic-needs (CBN) poverty lines that are utility consistent. Applications to date illustrate that utility-consistent poverty measurements derived from the proposed approach and those derived from current CBN best practices often differ substantially...

  9. Controlling the Biomimetic Implant Interface: Modulating Antimicrobial Activity by Spacer Design

    Science.gov (United States)

    Wisdom, Cate; Vanoosten, Sarah Kay; Boone, Kyle W.; Khvostenko, Dmytro; Arnold, Paul M.; Snead, Malcolm L.; Tamerler, Candan

    2016-08-01

    Surgical site infection is a common cause of post-operative morbidity, often leading to implant loosening, ultimately requiring revision surgery, increased costs and worse surgical outcomes. Since implant failure starts at the implant surface, creating and controlling the bio-material interface will play a critical role in reducing infection while improving host cell-to-implant interaction. Here, we engineered a biomimetic interface based upon a chimeric peptide that incorporates a titanium binding peptide (TiBP) with an antimicrobial peptide (AMP) into a single molecule to direct binding to the implant surface and deliver an antimicrobial activity against S. mutans and S. epidermidis, two bacteria which are linked with clinical implant infections. To optimize antimicrobial activity, we investigated the design of the spacer domain separating the two functional domains of the chimeric peptide. Lengthening and changing the amino acid composition of the spacer resulted in an improvement of minimum inhibitory concentration by a three-fold against S. mutans. Surfaces coated with the chimeric peptide reduced dramatically the number of bacteria, with up to a nine-fold reduction for S. mutans and a 48-fold reduction for S. epidermidis. Ab initio predictions of antimicrobial activity based on structural features were confirmed. Host cell attachment and viability at the biomimetic interface were also improved compared to the untreated implant surface. Biomimetic interfaces formed with this chimeric peptide offer interminable potential by coupling antimicrobial and improved host cell responses to implantable titanium materials, and this peptide based approach can be extended to various biomaterials surfaces.

  10. Preparation of the spacer for narrow electrode gap configuration in ionization-based gas sensor

    International Nuclear Information System (INIS)

    Saheed, Mohamed Shuaib Mohamed; Mohamed, Norani Muti; Burhanudin, Zainal Arif

    2012-01-01

    Carbon nanotubes (CNTs) have started to be developed as the sensing element for ionization-based gas sensors due to the demand for improved sensitivity, selectivity, stability and other sensing properties beyond what can be offered by the conventional ones. Although these limitations have been overcome, the problems still remain with the conventional ionization-based gas sensors in that they are bulky and operating with large breakdown voltage and high temperature. Recent studies have shown that the breakdown voltage can be reduced by using nanostructured electrodes and narrow electrode gap. Nanostructured electrode in the form of aligned CNTs array with evenly distributed nanotips can enhance the linear electric field significantly. The later is attributed to the shorter conductivity path through narrow electrode gap. The paper presents the study on the design consideration in order to realize ionization based gas sensor using aligned carbon nanotubes array in an optimum sensor configuration with narrow electrode gap. Several deposition techniques were studied to deposit the spacer, the key component that can control the electrode gap. Plasma spray deposition, electron beam deposition and dry oxidation method were employed to obtain minimum film thickness around 32 μm. For plasma spray method, sand blasting process is required in order to produce rough surface for strong bonding of the deposited film onto the surface. Film thickness, typically about 39 μm can be obtained. For the electron beam deposition and dry oxidation, the film thickness is in the range of nanometers and thus unsuitable to produce the spacer. The deposited multilayer film consisting of copper, alumina and ferum on which CNTs array will be grown was found to be removed during the etching process. This is attributed to the high etching rate on the thin film which can be prevented by reducing the rate and having a thicker conductive copper film.

  11. Preparation of the spacer for narrow electrode gap configuration in ionization-based gas sensor

    Energy Technology Data Exchange (ETDEWEB)

    Saheed, Mohamed Shuaib Mohamed; Mohamed, Norani Muti; Burhanudin, Zainal Arif [Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, Seri Iskandar, Tronoh, Perak. (Malaysia); Fundamental and Applied Science, Universiti Teknologi PETRONAS, Seri Iskandar, Tronoh, Perak. (Malaysia); Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, Seri Iskandar, Tronoh, Perak. (Malaysia)

    2012-09-26

    Carbon nanotubes (CNTs) have started to be developed as the sensing element for ionization-based gas sensors due to the demand for improved sensitivity, selectivity, stability and other sensing properties beyond what can be offered by the conventional ones. Although these limitations have been overcome, the problems still remain with the conventional ionization-based gas sensors in that they are bulky and operating with large breakdown voltage and high temperature. Recent studies have shown that the breakdown voltage can be reduced by using nanostructured electrodes and narrow electrode gap. Nanostructured electrode in the form of aligned CNTs array with evenly distributed nanotips can enhance the linear electric field significantly. The later is attributed to the shorter conductivity path through narrow electrode gap. The paper presents the study on the design consideration in order to realize ionization based gas sensor using aligned carbon nanotubes array in an optimum sensor configuration with narrow electrode gap. Several deposition techniques were studied to deposit the spacer, the key component that can control the electrode gap. Plasma spray deposition, electron beam deposition and dry oxidation method were employed to obtain minimum film thickness around 32 {mu}m. For plasma spray method, sand blasting process is required in order to produce rough surface for strong bonding of the deposited film onto the surface. Film thickness, typically about 39 {mu}m can be obtained. For the electron beam deposition and dry oxidation, the film thickness is in the range of nanometers and thus unsuitable to produce the spacer. The deposited multilayer film consisting of copper, alumina and ferum on which CNTs array will be grown was found to be removed during the etching process. This is attributed to the high etching rate on the thin film which can be prevented by reducing the rate and having a thicker conductive copper film.

  12. Effect of spacers on the thermal performance of an annular multi-layer insulation

    International Nuclear Information System (INIS)

    Haim, Y.; Weiss, Y.; Letan, R.

    2014-01-01

    The current study presents a model and is experimentally conducted in a system of 40 stainless steel coaxial foils, of nitrogen gas, entrapped between the foils, and of spacers, which are zirconia, spherical, 50 μm in size particles, widely dispersed in the gaps between the foils. The model, experimentally verified, relates to radiation between the foils, unobstructed by particles, to conduction in the nitrogen gas, and to conduction across the particles. The study was, in particular, aimed to measure the effective thermal conductivity of the particles and to assess its effect upon the array. At vacuum of 0.092 Pa, the effective thermal conductivity of the particles was 2.13 × 10 −4  W/m K, while the effective thermal conductivity of the array was 4.74 × 10 −4  W/m K. Thus, the low contribution of the particles conduction at vacuum conditions improves the insulation. It reaches 45% of the heat transfer rate. At atmospheric pressure, the effective thermal conductivity of the array reaches 4.5 × 10 −2  W/m K. There, the spacers contribution is negligible. - Highlights: •The multi-layer insulation of cylinder consists of foils separated by particles. •The particles are widely spaced in gaps. •Particles heat transfer rate is almost half of the total in vacuum. •At higher pressures the particles contribution is negligible. •The predicted thermal performance agrees with experimental results

  13. The effect of anterior proton beams in the setting of a prostate-rectum spacer

    Energy Technology Data Exchange (ETDEWEB)

    Christodouleas, John P., E-mail: christojo@uphs.upenn.edu [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, PA (United States); Tang, Shikui [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, PA (United States); Susil, Robert C.; McNutt, Todd R.; Song, Danny Y. [Department of Radiation Oncology and Radiation Molecular Sciences, Johns Hopkins Hospital, Baltimore, MD (United States); Bekelman, Justin; Deville, Curtiland; Vapiwala, Neha [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, PA (United States); DeWeese, Theodore L. [Department of Radiation Oncology and Radiation Molecular Sciences, Johns Hopkins Hospital, Baltimore, MD (United States); Lu, Hsiao-Ming [Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States); Both, Stefan [Department of Radiation Oncology, Hospital of the University of Pennsylvania, Philadelphia, PA (United States)

    2013-10-01

    Studies suggest that anterior beams with in vivo range verification would improve rectal dosimetry in proton therapy for prostate cancer. We investigated whether prostate-rectum spacers would enhance or diminish the benefits of anterior proton beams in these treatments. Twenty milliliters of hydrogel was injected between the prostate and rectum of a cadaver using a transperineal approach. Computed tomography (CT) and magnetic resonance (MR) images were used to generate 7 uniform scanning (US) and 7 single-field uniform dose pencil-beam scanning (PBS) plans with different beam arrangements. Pearson correlations were calculated between rectal, bladder, and femoral head dosimetric outcomes and beam arrangement anterior scores, which characterize the degree to which dose is delivered anteriorly. The overall quality of each plan was compared using a virtual dose-escalation study. For US plans, rectal mean dose was inversely correlated with anterior score, but for PBS plans there was no association between rectal mean dose and anterior score. For both US and PBS plans, full bladder and empty bladder mean doses were correlated with anterior scores. For both US and PBS plans, femoral head mean doses were inversely correlated with anterior score. For US plans and a full bladder, 4 beam arrangements that included an anterior beam tied for the highest maximum prescription dose (MPD). For US plans and an empty bladder, the arrangement with 1 anterior and 2 anterior oblique beams achieved the highest MPD in the virtual dose-escalation study. The dose-escalation study did not differentiate beam arrangements for PBS. All arrangements in the dose-escalation study were limited by bladder constraints except for the arrangement with 2 posterior oblique beams. The benefits of anterior proton beams in the setting of prostate-rectum spacers appear to be proton modality dependent and may not extend to PBS.

  14. The effect of anterior proton beams in the setting of a prostate-rectum spacer

    Science.gov (United States)

    Christodouleas, John P.; Tang, Shikui; Susil, Robert C.; McNutt, Todd R.; Song, Danny Y.; Bekelman, Justin; Deville, Curtiland; Vapiwala, Neha; DeWeese, Theodore L.; Lu, Hsiao-Ming; Both, Stefan

    2014-01-01

    Studies suggest that anterior beams with in vivo range verification would improve rectal dosimetry in proton therapy for prostate cancer. We investigated whether prostate-rectum spacers would enhance or diminish the benefits of anterior proton beams in these treatments. Twenty milliliters of hydrogel was injected between the prostate and rectum of a cadaver using a transperineal approach. Computed tomography (CT) and magnetic resonance (MR) images were used to generate 7 uniform scanning (US) and 7 single-field uniform dose pencil-beam scanning (PBS) plans with different beam arrangements. Pearson correlations were calculated between rectal, bladder, and femoral head dosimetric outcomes and beam arrangement anterior scores, which characterize the degree to which dose is delivered anteriorly. The overall quality of each plan was compared using a virtual dose-escalation study. For US plans, rectal mean dose was inversely correlated with anterior score, but for PBS plans there was no association between rectal mean dose and anterior score. For both US and PBS plans, full bladder and empty bladder mean doses were correlated with anterior scores. For both US and PBS plans, femoral head mean doses were inversely correlated with anterior score. For US plans and a full bladder, 4 beam arrangements that included an anterior beam tied for the highest maximum prescription dose (MPD). For US plans and an empty bladder, the arrangement with 1 anterior and 2 anterior oblique beams achieved the highest MPD in the virtual dose-escalation study. The dose-escalation study did not differentiate beam arrangements for PBS. All arrangements in the dose-escalation study were limited by bladder constraints except for the arrangement with 2 posterior oblique beams. The benefits of anterior proton beams in the setting of prostate-rectum spacers appear to be proton modality dependent and may not extend to PBS. PMID:23578497

  15. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  16. Employing 454 amplicon pyrosequencing to reveal intragenomic divergence in the internal transcribed spacer rDNA region in fungi

    Science.gov (United States)

    Daniel L. Lindner; Tor Carlsen; Henrik Nilsson; Marie Davey; Trond Schumacher; Havard. Kauserud

    2013-01-01

    The rDNA internal transcribed spacer (ITS) region has been accepted as a DNA barcoding marker for fungi and is widely used in phylogenetic studies; however, intragenomic ITS variability has been observed in a broad range of taxa, including prokaryotes, plants, animals, and fungi, and this variability has the potential to inflate species richness estimates in molecular...

  17. Saprolegniaceae identified on amphibian eggs throughout the Pacific Northwest, USA, by internal transcribed spacer sequences and phylogenetic analysis

    Science.gov (United States)

    Jill E. Petrisko; Christopher A. Pearl; David S. Pilliod; Peter P. Sheridan; Charles F. Williams; Charles R. Peterson; R. Bruce Bury

    2008-01-01

    We assessed the diversity and phylogeny of Saprolegniaceae on amphibian eggs from the Pacific Northwest, with particular focus on Saprolegnia ferax, a species implicated in high egg mortality. We identified isolates from eggs of six amphibians with the internal transcribed spacer (ITS) and 5.8S gene regions and BLAST of the GenBank database. We...

  18. The effect of spacer grid critical component on pressure drop under both single and two phase flow conditions

    International Nuclear Information System (INIS)

    Han, B.; Yang, B.W.; Zhang, H.; Mao, H.; Zha, Y.

    2016-01-01

    As pressure drop is one of the most critical thermal hydraulic parameters for spacer grids the accurate estimation of it is the key to the design and development of spacer grids. Most of the available correlations for pressure drop do not contain any real geometrical parameters that characterize the grid effect. The main functions for spacer grid are structural support and flow mixing. Once the boundary sublayer near the rod bundle is disturbed, the liquid forms swirls or flow separation that affect pressure drop. However, under two phase flow conditions, due to the existence of steam bubble, the complexity for spacer grid are multiplied and pressure drop calculation becomes much more challenging. The influence of the dimple location, distance of mixing vane to the nearest strip, and the effect of inter-subchannel mixing among neighboring subchannels on pressure drop and downstream flow fields are analyzed in this paper. Based on this study, more detailed space grid geometry parameters are recommended for adding into the correlation when predicting pressure drop.

  19. An improved PCR method for direct identification of Porphyra (Bangiales, Rhodophyta) using conchocelis based on a RUBISCO intergenic spacer

    Science.gov (United States)

    Wang, Chao; Dong, Dong; Wang, Guangce; Zhang, Baoyu; Peng, Guang; Xu, Pu; Tang, Xiaorong

    2009-09-01

    An improved method of PCR in which the small segment of conchocelis is amplified directly without DNA extraction was used to amplify a RUBISCO intergenic spacer DNA fragment from nine species of red algal genus Porphyra (Bangiales, Rhodophyta), including Porphyra yezoensis (Jiangsu, China), P. haitanensis (Fujian, China), P. oligospermatangia (Qingdao, China), P. katadai (Qingdao, China), P. tenera (Qingdao, China), P. suborboculata (Fujian, China), P. pseudolinearis (Kogendo, Korea), P. linearis (Devon, England), and P. fallax (Seattle, USA). Standard PCR and the method developed here were both conducted using primers specific for the RUBISCO spacer region, after which the two PCR products were sequenced. The sequencing data of the amplicons obtained using both methods were identical, suggesting that the improved PCR method was functional. These findings indicate that the method developed here may be useful for the rapid identification of species of Porphyra in a germplasm bank. In addition, a phylogenetic tree was constructed using the RUBISCO spacer and partial rbcS sequence, and the results were in concordant with possible alternative phylogenies based on traditional morphological taxonomic characteristics, indicating that the RUBISCO spacer is a useful region for phylogenetic studies.

  20. A simulation study on the variation of virtual NMR signals by winding, bobbin, spacer error of HTS magnet

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Seong; Lee, Woo Seung; Kim, Jin Sub; Song, Seung Hyun; Nam, Seok Ho; Jeon, Hae Ryong; Beak, Geon Woo; Ko, Tae Kuk [Yonsei University, Seoul (Korea, Republic of)

    2016-09-15

    Recently, production technique and property of the High-Temperature Superconductor (HTS) tape have been improved. Thus, the study on applying an HTS magnet to the high magnetic field application is rapidly increased. A Nuclear Magnetic Resonance (NMR) spectrometer requires high magnitude and homogeneous of central magnetic field. However, the HTS magnet has fabrication errors because shape of HTS is tape and HTS magnet is manufactured by winding HTS tape to the bobbin. The fabrication errors are winding error, bobbin diameter error, spacer thickness error and so on. The winding error occurs when HTS tape is departed from the arranged position on the bobbin. The bobbin diameter and spacer thickness error occur since the diameter of bobbin and spacer are inaccurate. These errors lead magnitude and homogeneity of central magnetic field to be different from its ideal design. The purpose of this paper is to investigate the effect of winding error, bobbin diameter error and spacer thickness error on the central field and field homogeneity of HTS magnet using the virtual NMR signals in MATLAB simulation.